Sample records for facet joint capsule

  1. Bipolar Radiofrequency Facet Ablation of the Lumbar Facet Capsule: An Adjunct to Conventional Radiofrequency Ablation for Pain Management.

    PubMed

    Jacobson, Robert E; Palea, Ovidiu; Granville, Michelle

    2017-09-01

    Radiofrequency facet ablation (RFA) has been performed using the same technique for over 50 years. Except for variations in electrode size, tip shape, and change in radiofrequency (RF) stimulation parameters, using standard, pulsed, and cooled RF wavelengths, the target points have remained absolutely unchanged from the original work describing RFA for lumbar pain control. Degenerative changes in the facet joint and capsule are the primary location for the majority of lumbar segmental pathology and pain. Multiple studies show that the degenerated facet joint is richly innervated as a result of the inflammatory overgrowth of the synovium. The primary provocative clinical test to justify an RFA is to perform an injection with local anesthetic into the facet joint and the posterior capsule and confirm pain relief. However, after a positive response, the radiofrequency lesion is made not to the facet joint but to the more proximal fine nerve branches that innervate the joint. The accepted target points for the recurrent sensory branch ignore the characteristic rich innervation of the pathologic lumbar facet capsule and assume that lesioning of these recurrent branches is sufficient to denervate the painful pathologic facet joint. This report describes the additional targets and technical steps for further coagulation points along the posterior capsule of the lumbar facet joint and the physiologic studies of the advantage of the bipolar radiofrequency current in this location. Bipolar RF to the facet capsule is a simple, extra step that easily creates a large thermo-coagulated lesion in this capsule region of the pathologic facet joint. Early studies demonstrate bipolar RF to the facet capsule can provide long-term pain relief when used alone for specific localized facet joint pain, to coagulate lumbar facet cysts to prevent recurrence, and to get more extensive pain control by combining it with traditional lumbar RFA, especially when RFA is repeated.

  2. Percutaneous radiofrequency facet capsule denervation as an alternative target in lumbar facet syndrome.

    PubMed

    Moussa, Wael Mohamed Mohamed; Khedr, Wael

    2016-11-01

    Percutaneous radiofrequency denervation of the medial dorsal branch is often used in chronic low back pain of intervertebral facet etiology, which is sometimes difficult to perform and recurrence of pain often ensues. We theorized that shifting the target of RF coagulation to the facet joint capsule would provide an easier target and a longer-lived pain relieving response. A prospective randomized controlled trial where 120 patients diagnosed with CLBP of a confirmed facet origin were randomly divided into three equal groups, the first was submitted to percutaneous radiofrequency coagulation of the facet joint capsule, the second underwent percuataneous denervation of the medial dorsal branch and the third did not receive radiofrequency lesioning. All the three groups received local injection of a mixture of local anesthetic and steroid. Cases were followed for up to 3 years. 87(72.5%) patients were females. By 3 months' post procedure, improvement in VAS was significantly better than pretreatment levels in all groups (p<0.05). The control group lost improvement by 1-year follow-up (p=0.017). At 2 years' follow-up, the joint capsule denervation group maintained significant improvement (p=0.033) whereas the medial branch denervation group lost its significant effect (p=0.479). By the end of follow-up period, only joint capsule denervation group kept significant improvement (p=0.026). In CLBP of facet origin, shifting the target of percutaneous radiofrequency to the facet joint capsule provides an easier technique with an extended period of pain relief compared to the medial dorsal branch of the facet joint. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Bipolar Radiofrequency Facet Ablation of the Lumbar Facet Capsule: An Adjunct to Conventional Radiofrequency Ablation for Pain Management

    PubMed Central

    Palea, Ovidiu; Granville, Michelle

    2017-01-01

    Radiofrequency facet ablation (RFA) has been performed using the same technique for over 50 years. Except for variations in electrode size, tip shape, and change in radiofrequency (RF) stimulation parameters, using standard, pulsed, and cooled RF wavelengths, the target points have remained absolutely unchanged from the original work describing RFA for lumbar pain control. Degenerative changes in the facet joint and capsule are the primary location for the majority of lumbar segmental pathology and pain. Multiple studies show that the degenerated facet joint is richly innervated as a result of the inflammatory overgrowth of the synovium. The primary provocative clinical test to justify an RFA is to perform an injection with local anesthetic into the facet joint and the posterior capsule and confirm pain relief. However, after a positive response, the radiofrequency lesion is made not to the facet joint but to the more proximal fine nerve branches that innervate the joint. The accepted target points for the recurrent sensory branch ignore the characteristic rich innervation of the pathologic lumbar facet capsule and assume that lesioning of these recurrent branches is sufficient to denervate the painful pathologic facet joint. This report describes the additional targets and technical steps for further coagulation points along the posterior capsule of the lumbar facet joint and the physiologic studies of the advantage of the bipolar radiofrequency current in this location. Bipolar RF to the facet capsule is a simple, extra step that easily creates a large thermo-coagulated lesion in this capsule region of the pathologic facet joint. Early studies demonstrate bipolar RF to the facet capsule can provide long-term pain relief when used alone for specific localized facet joint pain, to coagulate lumbar facet cysts to prevent recurrence, and to get more extensive pain control by combining it with traditional lumbar RFA, especially when RFA is repeated. PMID

  4. Direct Posterior Bipolar Cervical Facet Radiofrequency Rhizotomy: A Simpler and Safer Approach to Denervate the Facet Capsule.

    PubMed

    Palea, Ovidiu; Andar, Haroon M; Lugo, Ramon; Granville, Michelle; Jacobson, Robert E

    2018-03-14

    Radiofrequency cervical rhizotomy has been shown to be effective for the relief of chronic neck pain, whether it be due to soft tissue injury, cervical spondylosis, or post-cervical spine surgery. The target and technique have traditionally been taught using an oblique approach to the anterior lateral capsule of the cervical facet joint. The goal is to position the electrode at the proximal location of the recurrent branch after it leaves the exiting nerve root and loops back to the cervical facet joint. The standard oblique approach to the recurrent nerve requires the testing of both motor and sensory components to verify the correct position and ensure safety so as to not damage the slightly more anterior nerve root. Bilateral lesions require the repositioning of the patient's neck. Poorly positioned electrodes can also pass anteriorly and contact the nerve root or vertebral artery. The direct posterior approach presented allows electrode positioning over a broader expanse of the facet joint without risk to the nerve root or vertebral artery. Over a four-year period, direct posterior radiofrequency ablation was performed under fluoroscopic guidance at multiple levels without neuro-stimulation testing with zero procedural neurologic events even as high as the C2 spinal segment. The direct posterior approach allows either unipolar or bipolar lesioning at multiple levels. Making a radiofrequency lesion along the larger posterior area of the facet capsule is as effective as the traditional target point closer to the nerve root but technically easier, allowing bilateral access and safety. The article will review the anatomy and innervation of the cervical facet joint and capsule, showing the diffuse nerve supply extending into the capsule of the facet joint that is more extensive than the recurrent medial sensory branches that have been the focus of radiofrequency lesioning.

  5. Direct Posterior Bipolar Cervical Facet Radiofrequency Rhizotomy: A Simpler and Safer Approach to Denervate the Facet Capsule

    PubMed Central

    Palea, Ovidiu; Andar, Haroon M; Lugo, Ramon; Jacobson, Robert E

    2018-01-01

    Radiofrequency cervical rhizotomy has been shown to be effective for the relief of chronic neck pain, whether it be due to soft tissue injury, cervical spondylosis, or post-cervical spine surgery. The target and technique have traditionally been taught using an oblique approach to the anterior lateral capsule of the cervical facet joint. The goal is to position the electrode at the proximal location of the recurrent branch after it leaves the exiting nerve root and loops back to the cervical facet joint. The standard oblique approach to the recurrent nerve requires the testing of both motor and sensory components to verify the correct position and ensure safety so as to not damage the slightly more anterior nerve root. Bilateral lesions require the repositioning of the patient's neck. Poorly positioned electrodes can also pass anteriorly and contact the nerve root or vertebral artery. The direct posterior approach presented allows electrode positioning over a broader expanse of the facet joint without risk to the nerve root or vertebral artery. Over a four-year period, direct posterior radiofrequency ablation was performed under fluoroscopic guidance at multiple levels without neuro-stimulation testing with zero procedural neurologic events even as high as the C2 spinal segment. The direct posterior approach allows either unipolar or bipolar lesioning at multiple levels. Making a radiofrequency lesion along the larger posterior area of the facet capsule is as effective as the traditional target point closer to the nerve root but technically easier, allowing bilateral access and safety. The article will review the anatomy and innervation of the cervical facet joint and capsule, showing the diffuse nerve supply extending into the capsule of the facet joint that is more extensive than the recurrent medial sensory branches that have been the focus of radiofrequency lesioning. PMID:29765790

  6. Migrating lumbar facet joint cysts.

    PubMed

    Palmieri, Francesco; Cassar-Pullicino, Victor N; Lalam, Radhesh K; Tins, Bernhard J; Tyrrell, Prudencia N M; McCall, Iain W

    2006-04-01

    The majority of lumbar facet joint cysts (LFJCs) are located in the spinal canal, on the medial aspect of the facet joint with characteristic diagnostic features. When they migrate away from the joint of origin, they cause diagnostic problems. In a 7-year period we examined by computed tomography (CT) and magnetic resonance (MR) imaging five unusual cases of facet joint cysts which migrated from the facet joint of origin. Three LFJCs were identified in the right S1 foramen, one in the right L5-S1 neural foramen and one in the left erector spinae and multifidus muscles between the levels of L2-L4 spinous process. Awareness that spinal lesions identified at MRI and CT could be due to migrating facet joint cyst requires a high level of suspicion. The identification of the appositional contact of the cyst and the facet joint needs to be actively sought in the presence of degenerative facet joints.

  7. Arthrofibrosis involving the middle facet of the talocalcaneal joint in children and adolescents.

    PubMed

    El Rassi, George; Riddle, Eric C; Kumar, S Jay

    2005-10-01

    Pain over the anterolateral aspect of the ankle in a patient with a history of repeated ankle sprains and with restricted subtalar movement may be associated with a tarsal coalition. Nineteen patients presented with such a history, but conventional imaging did not reveal a cartilaginous or osseous coalition. Since symptoms persisted despite nonoperative treatment, the middle facet was explored surgically. The purpose of this study was to discuss the operative findings and to report the results of treatment. Nineteen patients (twenty-three feet) with pain over the anterolateral aspect of the ankle or a history of repeated ankle sprains had restricted subtalar joint motion and inconclusive findings on diagnostic imaging, except for bone-scanning. Their ages ranged from 9.1 to 18.5 years. The middle facet of the subtalar joint was explored surgically through a 3 to 4-cm-long incision centered over the sustentaculum tali. The results at a mean of 5.8 years were classified as good, fair, or poor on the basis of pain, talocalcaneal joint motion, and shoe wear. Routine radiographs, computed tomography, and magnetic resonance imaging revealed no major abnormality, whereas technetium-99m bone scintigraphy consistently showed slightly increased isotope uptake in the middle facet. Surgical removal of a hypervascular and thickened capsule and synovium in the area of the middle facet of the subtalar joint decreased pain and improved subtalar motion. The final result was good in seventeen patients (twenty feet) and fair in two patients (three feet). There were no poor results. A diagnosis of inflammatory arthrofibrosis should be considered when a patient with a painful rigid flatfoot has normal findings on radiographs and hematological studies but increased isotope uptake in the middle facet of the talocalcaneal joint on bone scintigraphy. Excision of the hypervascular capsule and synovium from this area can result in resolution of the symptoms. Therapeutic Level IV.

  8. Human Lumbar Spine Creep during Cyclic and Static Flexion: Creep Rate, Biomechanics, and Facet Joint Capsule Strain

    PubMed Central

    Little, Jesse S.; Khalsa, Partap S.

    2005-01-01

    There is a high incidence of low back pain (LBP) associated with occupations requiring sustained and/or repetitive lumbar flexion (SLF and RLF, respectively), which cause creep of the viscoelastic tissues. The purpose of this study was to determine the effect of creep on lumbar biomechanics and facet joint capsule (FJC) strain. Specimens were flexed for 10 cycles, to a maximum 10 Nm moment at L5-S1, before, immediately after, and 20 min after a 20-min sustained flexion at the same moment magnitude. The creep rates of SLF and RLF were also measured during each phase and compared to the creep rate predicted by the moment relaxation rate function of the lumbar spine. Both SLF and RLF resulted in significantly increased intervertebral motion, as well as significantly increased FJC strains at the L3-4 to L5-S1 joint levels. These parameters remained increased after the 20-min recovery. Creep during SLF occurred significantly faster than creep during RLF. The moment relaxation rate function was able to accurately predict the creep rate of the lumbar spine at the single moment tested. The data suggest that SLF and RLF result in immediate and residual laxity of the joint and stretch of the FJC, which could increase the potential for LBP. PMID:15868730

  9. Contact pressure in the facet joint during sagittal bending of the cadaveric cervical spine.

    PubMed

    Jaumard, Nicolas V; Bauman, Joel A; Weisshaar, Christine L; Guarino, Benjamin B; Welch, William C; Winkelstein, Beth A

    2011-07-01

    The facet joint contributes to the normal biomechanical function of the spine by transmitting loads and limiting motions via articular contact. However, little is known about the contact pressure response for this joint. Such information can provide a quantitative measure of the facet joint's local environment. The objective of this study was to measure facet pressure during physiologic bending in the cervical spine, using a joint capsule-sparing technique. Flexion and extension bending moments were applied to six human cadaveric cervical spines. Global motions (C2-T1) were defined using infra-red cameras to track markers on each vertebra. Contact pressure in the C5-C6 facet was also measured using a tip-mounted pressure transducer inserted into the joint space through a hole in the postero-inferior region of the C5 lateral mass. Facet contact pressure increased by 67.6 ± 26.9 kPa under a 2.4 Nm extension moment and decreased by 10.3 ± 9.7 kPa under a 2.7 Nm flexion moment. The mean rotation of the overall cervical specimen motion segments was 9.6 ± 0.8° and was 1.6 ± 0.7° for the C5-C6 joint, respectively, for extension. The change in pressure during extension was linearly related to both the change in moment (51.4 ± 42.6 kPa/Nm) and the change in C5-C6 angle (18.0 ± 108.9 kPa/deg). Contact pressure in the inferior region of the cervical facet joint increases during extension as the articular surfaces come in contact, and decreases in flexion as the joint opens, similar to reports in the lumbar spine despite the difference in facet orientation in those spinal regions. Joint contact pressure is linearly related to both sagittal moment and spinal rotation. Cartilage degeneration and the presence of meniscoids may account for the variation in the pressure profiles measured during physiologic sagittal bending. This study shows that cervical facet contact pressure can be directly measured with minimal disruption to the joint and is the first to provide local

  10. A novel approach to symptomatic lumbar facet joint synovial cyst injection and rupture using iGuide navigational software: A case report and review.

    PubMed

    Wang, David J; Lownie, Stephen P; Pelz, David; Pandey, Sachin

    2016-10-01

    Spinal synovial cysts are benign protrusions of facet joint capsules caused by degenerative spondylosis, most frequently involving the L4-5 level, and commonly lead to symptoms of back pain, radiculopathy and neurogenic claudication. Although percutaneous treatment via facet joint steroid injection with cyst rupture can provide significant symptom relief, cyst rupture is not always achievable via an indirect trans-facet approach due to limited access from severe degenerative changes. In this case, we describe a successful approach to direct cyst access using a laser-guided navigational software in a patient with severe facet joint osteophytosis. We provide a brief review of literature. © The Author(s) 2016.

  11. A study of cervical spine kinematics and joint capsule strain in rear impacts using a human FE model.

    PubMed

    Kitagawa, Yuichi; Yasuki, Tsuyoshi; Hasegawa, Junji

    2006-11-01

    Many efforts have been made to understand the mechanism of whiplash injury. Recently, the cervical facet joint capsules have been focused on as a potential site of injury. An experimental approach has been taken to analyze the vertebral motion and to estimate joint capsule stretch that was thought to be a potential cause of pain. The purpose of this study is to analyze the kinematics of the cervical facet joint using a human FE model in order to better understand the injury mechanism. The Total Human Model for Safety (THUMS) was used to visually analyze the local and global kinematics of the spine. Soft tissues in the neck were newly modeled and introduced into THUMS for estimating the loading level in rear impacts. The model was first validated against human test data in the literature by comparing vertebrae motion as well as head and neck responses. Joint capsule strain was estimated from a maximum principal strain output from the elements representing the capsule tissues. A rear-end collision was then simulated using THUMS and a prototype seat model, assuming a delta-V of 25 km/h. The trajectory of the vertebrae was analyzed in a local coordinate system defined along the joint surface. Strain growth in the joint capsules was explained, as related to contact events between the occupant and the seat. A new seat concept was proposed to help lessen the loading level to the neck soft tissues. The foam material of the seat back was softened, the initial gap behind the head was reduced and the head restraint was stiffened for firm support. The lower seat back frame was also reinforced to withstand the impact severity at the given delta-V. Another rear impact simulation was conducted using the new seat concept model to examine the effectiveness of the new concept. The joint capsule strain was found to be relatively lower with the new seat concept. The study also discusses the influence of seat parameters to the vertebral motion and the resultant strain in the joint

  12. Superior Recess Access of the Lumbar Facet Joint.

    PubMed

    Demir-Deviren, Sibel; Singh, Sukhminder; Hanelin, Joshua

    2017-04-01

    Descriptive approach to accessing the lumbar facet joint by superior recess. This study is aimed to describe an approach to accessing the lumbar facet joint through targeting the superior recess during lumbar facet joint injections. Lumbar facet joint injections are routinely performed for both the diagnosis and treatment of chronic low back pain. Previous studies either did not specify which part of the joint to target, or recommended targeting the inferior aspect of the joint to access the inferior recess. One study did mention the superior recess as an alternative to injecting the inferior recess, but none has focused on description of the technique. This is the first time this technique has been described. The records and fluoroscopic images were reviewed for all patients over a period of 9 months (January-September 2012) using the proposed technique. This resulted in a total of 48 patients; 15 men, 29 women, and a total of 117 facet joint intra-articular injections. Among these 48 patients, injections were repeated in total of 4 cases. The average time of injections among 4 repeat cases was 121 days. The success of the procedure was confirmed with an arthrogram demonstrating contrast flowing from the superior recess inferiorly through the joint space. Successful access of the lumbar facet joint through puncture of the superior recess was seen in 114 cases, with 3 unsuccessful attempts to enter facet joints due to osteophytes at involved levels. There were no complications observed during the procedure. We find this approach to be highly successful, safe, and well tolerated by the patient and recommend it as a technique for access of the lumbar facet joint in those patients in whom direct puncture of the inferior recess is difficult.

  13. Augmented Reality-Guided Lumbar Facet Joint Injections.

    PubMed

    Agten, Christoph A; Dennler, Cyrill; Rosskopf, Andrea B; Jaberg, Laurenz; Pfirrmann, Christian W A; Farshad, Mazda

    2018-05-08

    The aim of this study was to assess feasibility and accuracy of augmented reality-guided lumbar facet joint injections. A spine phantom completely embedded in hardened opaque agar with 3 ring markers was built. A 3-dimensional model of the phantom was uploaded to an augmented reality headset (Microsoft HoloLens). Two radiologists independently performed 20 augmented reality-guided and 20 computed tomography (CT)-guided facet joint injections each: for each augmented reality-guided injection, the hologram was manually aligned with the phantom container using the ring markers. The radiologists targeted the virtual facet joint and tried to place the needle tip in the holographic joint space. Computed tomography was performed after each needle placement to document final needle tip position. Time needed from grabbing the needle to final needle placement was measured for each simulated injection. An independent radiologist rated images of all needle placements in a randomized order blinded to modality (augmented reality vs CT) and performer as perfect, acceptable, incorrect, or unsafe. Accuracy and time to place needles were compared between augmented reality-guided and CT-guided facet joint injections. In total, 39/40 (97.5%) of augmented reality-guided needle placements were either perfect or acceptable compared with 40/40 (100%) CT-guided needle placements (P = 0.5). One augmented reality-guided injection missed the facet joint space by 2 mm. No unsafe needle placements occurred. Time to final needle placement was substantially faster with augmented reality guidance (mean 14 ± 6 seconds vs 39 ± 15 seconds, P < 0.001 for both readers). Augmented reality-guided facet joint injections are feasible and accurate without potentially harmful needle placement in an experimental setting.

  14. Facet joint hypertrophy is a misnomer: A retrospective study.

    PubMed

    An, Sang Joon; Seo, Mi Sook; Choi, Soo Il; Lim, Tae-Ha; Shin, So Jin; Kang, Keum Nae; Kim, Young Uk

    2018-06-01

    One of the major causes of lumbar spinal canal stenosis (LSCS) has been considered facet joint hypertrophy (FJH). However, a previous study asserted that "FJH" is a misnomer because common facet joints are no smaller than degenerative facet joints; however, this hypothesis has not been effectively demonstrated. Therefore, in order to verify that FJH is a misnomer in patients with LSCS, we devised new morphological parameters that we called facet joint thickness (FJT) and facet joint cross-sectional area (FJA).We collected FJT and FJA data from 114 patients with LSCS. A total of 86 control subjects underwent lumbar magnetic resonance imaging (MRI) as part of routine medical examinations, and axial T2-weighted MRI images were obtained from all participants. We measured FJT by drawing a line along the facet area and then measuring the narrowest point at L4-L5. We measured FJA as the whole cross-sectional area of the facet joint at the stenotic L4-L5 level.The average FJT was 1.60 ± 0.36 mm in the control group and 1.11 ± 0.32 mm in the LSCS group. The average FJA was 14.46 ± 5.17 mm in the control group and 9.31 ± 3.47 mm in the LSCS group. Patients with LSCS had significantly lower FJTs (P < .001) and FJAs (P < .001).FJH, a misnomer, should be renamed facet joint area narrowing. Using this terminology would eliminate confusion in descriptions of the facet joint.

  15. Surgical Tips to Preserve the Facet Joint during Microdiscectomy

    PubMed Central

    Park, Man-Kyu; Cho, Dae-Chul; Sung, Joo-Kyung

    2013-01-01

    Lumbar microdiscectomy (MD) is the gold standard for treatment of lumbar disc herniation. Generally, the surgeon attempts to protect the facet joint in hopes of avoiding postoperative pain/instability and secondary degenerative arthropathy. We believe that preserving the facet joint is especially important in young patients, owing to their life expectancy and activity. However, preserving the facet joint is not easy during lumbar MD. We propose several technical tips (superolateral extension of conventional laminotomy, oblique drilling for laminotomy, and additional foraminotomy) for facet joint preservation during lumbar MD. PMID:24294466

  16. Management of lumbar zygapophysial (facet) joint pain

    PubMed Central

    Manchikanti, Laxmaiah; Hirsch, Joshua A; Falco, Frank JE; Boswell, Mark V

    2016-01-01

    AIM: To investigate the diagnostic validity and therapeutic value of lumbar facet joint interventions in managing chronic low back pain. METHODS: The review process applied systematic evidence-based assessment methodology of controlled trials of diagnostic validity and randomized controlled trials of therapeutic efficacy. Inclusion criteria encompassed all facet joint interventions performed in a controlled fashion. The pain relief of greater than 50% was the outcome measure for diagnostic accuracy assessment of the controlled studies with ability to perform previously painful movements, whereas, for randomized controlled therapeutic efficacy studies, the primary outcome was significant pain relief and the secondary outcome was a positive change in functional status. For the inclusion of the diagnostic controlled studies, all studies must have utilized either placebo controlled facet joint blocks or comparative local anesthetic blocks. In assessing therapeutic interventions, short-term and long-term reliefs were defined as either up to 6 mo or greater than 6 mo of relief. The literature search was extensive utilizing various types of electronic search media including PubMed from 1966 onwards, Cochrane library, National Guideline Clearinghouse, clinicaltrials.gov, along with other sources including previous systematic reviews, non-indexed journals, and abstracts until March 2015. Each manuscript included in the assessment was assessed for methodologic quality or risk of bias assessment utilizing the Quality Appraisal of Reliability Studies checklist for diagnostic interventions, and Cochrane review criteria and the Interventional Pain Management Techniques - Quality Appraisal of Reliability and Risk of Bias Assessment tool for therapeutic interventions. Evidence based on the review of the systematic assessment of controlled studies was graded utilizing a modified schema of qualitative evidence with best evidence synthesis, variable from level I to level V

  17. Biochemical and biomechanical characterisation of equine cervical facet joint cartilage.

    PubMed

    O'Leary, S A; White, J L; Hu, J C; Athanasiou, K A

    2018-04-15

    The equine cervical facet joint is a site of significant pathology. Located bilaterally on the dorsal spine, these diarthrodial joints work in conjunction with the intervertebral disc to facilitate appropriate spinal motion. Despite the high prevalence of pathology in this joint, the facet joint is understudied and thus lacking in viable treatment options. The goal of this study was to characterise equine facet joint cartilage and provide a comprehensive database describing the morphological, histological, biochemical and biomechanical properties of this tissue. Descriptive cadaver studies. A total of 132 facet joint surfaces were harvested from the cervical spines of six skeletally mature horses (11 surfaces per animal) for compiling biomechanical and biochemical properties of hyaline cartilage of the equine cervical facet joints. Gross morphometric measurements and histological staining were performed on facet joint cartilage. Creep indentation and uniaxial strain-to-failure testing were used to determine the biomechanical compressive and tensile properties. Biochemical assays included quantification of total collagen, sulfated glycosaminoglycan and DNA content. The facet joint surfaces were ovoid in shape with a flat articular surface. Histological analyses highlighted structures akin to articular cartilage of other synovial joints. In general, biomechanical and biochemical properties did not differ significantly between the inferior and superior joint surfaces as well as among spinal levels. Interestingly, compressive and tensile properties of cervical facet articular cartilage were lower than those of articular cartilage from other previously characterised equine joints. Removal of the superficial zone reduced the tissue's tensile strength, suggesting that this zone is important for the tensile integrity of the tissue. Facet surfaces were sampled at a single, central location and do not capture the potential topographic variation in cartilage properties. This

  18. Localized cervical facet joint kinematics under physiological and whiplash loading.

    PubMed

    Stemper, Brian D; Yoganandan, Narayan; Gennarelli, Thomas A; Pintar, Frank A

    2005-12-01

    Although facet joints have been implicated in the whiplash injury mechanism, no investigators have determined the degree to which joint motions in whiplash are nonphysiological. The purpose of this investigation was to quantify the correlation between facet joint and segmental motions under physiological and whiplash loading. Human cadaveric cervical spine specimens were exercise tested under physiological extension loading, and intact human head-neck complexes were exercise tested under whiplash loading to correlate the localized component motions of the C4-5 facet joint with segmental extension. Facet joint shear and distraction kinematics demonstrated a linear correlation with segmental extension under both loading modes. Facet joints responded differently to whiplash and physiological loading, with significantly increased kinematics for the same-segmental angulation. The limitations of this study include removal of superficial musculature and the limited sample size for physiological testing. The presence of increased facet joint motions indicated that synovial joint soft-tissue components (that is, synovial membrane and capsular ligament) sustain increased distortion that may subject these tissues to a greater likelihood of injury. This finding is supported by clinical investigations in which lower cervical facet joint injury resulted in similar pain patterns due to the most commonly reported whiplash symptoms.

  19. Facet joint disturbance induced by miniscrews in plated cervical laminoplasty

    PubMed Central

    Chen, Hua; Li, Huibo; Wang, Beiyu; Li, Tao; Gong, Quan; Song, Yueming; Liu, Hao

    2016-01-01

    Abstract A retrospective cohort study. Plated cervical laminoplasty is an increasingly common technique. A unique facet joint disturbance induced by lateral mass miniscrews penetrating articular surface was noticed. Facet joints are important to maintain cervical spine stability and kinetic balance. Whether this facet joint disturbance could affect clinical and radiologic results is still unknown. The objective of this study is to investigate the clinical and radiologic outcomes of patients with facet joints disturbance induced by miniscrews in plated cervical laminoplasty. A total of 105 patients who underwent cervical laminoplasty with miniplate fixation between May 2010 and February 2014 were comprised. Postoperative CT images were used to identify whether facet joints destroyed by miniscrews. According to facet joints destroyed number, all the patients were divided into: group A (none facet joint destroyed), group B (1–2 facet joints destroyed), and group C (≥3 facet joints destroyed). Clinical data (JOA, VAS, and NDI scores), radiologic data (anteroposterior diameter and Palov ratio), and complications (axial symptoms and C5 palsy) were evaluated and compared among the groups. There were 38, 40, and 27 patients in group A, B, and C, respectively. The overall facet joints destroyed rate was 30.7%. All groups gained significant JOA and NDI scores improvement postoperatively. The preoperative JOA, VAS, NDI scores, and postoperative JOA scores did not differ significantly among the groups. The group C recorded significant higher postoperative VAS scores than group A (P = 0.002) and B (P = 0.014) and had significant higher postoperative NDI scores than group A (P = 0.002). The pre- and postoperative radiologic data were not significant different among the groups. The group C had a significant higher axial symptoms incidence than group A (12/27 vs 8/38, P = 0.041). Facet joints disturbance caused by miniscrews in plated cervical laminoplasty may not influence

  20. Utilization of Facet Joint and Sacroiliac Joint Interventions in Medicare Population from 2000 to 2014: Explosive Growth Continues!

    PubMed

    Manchikanti, Laxmaiah; Hirsch, Joshua A; Pampati, Vidyasagar; Boswell, Mark V

    2016-10-01

    Increasing utilization of interventional techniques in managing chronic spinal pain, specifically facet joint interventions and sacroiliac joint injections, is a major concern of healthcare policy makers. We analyzed the patterns of utilization of facet and sacroiliac joint interventions in managing chronic spinal pain. The results showed significant increase of facet joint interventions and sacroiliac joint injections from 2000 to 2014 in Medicare FFS service beneficiaries. Overall, the Medicare population increased 35 %, whereas facet joint and sacroiliac joint interventions increased 313.3 % per 100,000 Medicare population with an annual increase of 10.7 %. While the increases were uniform from 2000 to 2014, there were some decreases noted for facet joint interventions in 2007, 2010, and 2013, whereas for sacroiliac joint injections, the decreases were noted in 2007 and 2013. The increases were for cervical and thoracic facet neurolysis at 911.5 % compared to lumbosacral facet neurolysis of 567.8 %, 362.9 % of cervical and thoracic facet joint blocks, 316.9 % of sacroiliac joints injections, and finally 227.3 % of lumbosacral facet joint blocks.

  1. Facet joint laser radiation: tissue effects of a new clinical laser application

    NASA Astrophysics Data System (ADS)

    Werkmann, Klaus; Thal, Dietmar R.

    1996-01-01

    Chronic unilateral and bilateral back pain with pseudoradicular symptoms, is a common clinical syndrome, which in many cases can be related to the facet joint syndrome. The pain is caused by mechanical affection of synovial and capsular nerve terminals. Therefore, current therapeutical attempts including physical therapy, intra-articular injection of local anesthetics and steroids and thermocoagulation of the facet joint with a thermocoagulator, are performed. We confirmed laser coagulation of the facet joint. Porcine cadaveric spines were treated immediately after death by intra-articular facet joint laser radiation. With the pulsed Nd:YAG laser (1064 nm) altogether 600 J were applied in three different places 4 mm apart at the top of the facet joint. The results showed that facet joint laser radiation leads to a small (about 1 - 2 mm diameter) lesion restricted to the facet joint cavity and its synovia. Histologically, we found a central carbonization zone and necrosis, including almost the whole cartilage and approximately 0.2 mm of the adjacent bone. These changes are similar to Nd:Yag-laser applications in other skeletal regions. It is suggested that these changes may lead to facet joint denervation by coagulation of the synovial nerve terminals. Cicatration of the laser lesion might cause ankylosis of this joint. In sum, facet joint laser radiation could be an alternative therapeutical tool for lower back pain of the facet joint syndrome type. Therefore, future clinical application of this technique seems to be very promising.

  2. Three-dimensional evaluation of the facet joints

    NASA Astrophysics Data System (ADS)

    Folio, Les R.

    1990-04-01

    Computerized tomography and magnetic resonance imaging nave revolurionalized analysis of vertebral anatomy and pathology. Further advances with 3-dimensional imaging have recently become an important adjunct for diagnosis and treatment in structural abnormalities. Facets are intimately related to their surrounding musculature and malalignment may cause pain directly or indirectly. High resolution 3-dimensional reformations of CT Scans give us new insight on structure and function of facet joints, since their motion and architecture are ever complex. It is well documented in the literature that facet joint biomecnanics is a partial contributor to the myriad at causes of low back The term "facet Joint syndrome" was coined in 1933 by GhorMley.3 The osteopathic lesion complex is well defined by LeRoy and McCole and comparison of roentgenographic findings before and after manipulation has teen described by Long and Lioyd.4,5 since alterations in facet biamechanics are an important aspect of osteopathic manipulative therapy (OT), 3-dimensional hign resolution imaging will prove to be a great asset in osteopathic research. Rotating the spine allows for different viewing perspectives to provide optimal and consistent measurements of the facet joint. Rotations are performed on the X, Y and 7, axis and measurements pre and post-manipulation are performed and compared on matching axis and perspectives. Rotation about the X, Y and Z axis help appreciate the 3-dimensionality of the vertebral column to project to the viewer a feeling that the spine is floating in space before them. This does give the viewer a 3-D understanding of the object however, only at a perspective at a Lime.

  3. Correlation of the Features of the Lumbar Multifidus Muscle With Facet Joint Osteoarthritis.

    PubMed

    Yu, Bo; Jiang, Kaibiao; Li, Xinfeng; Zhang, Jidong; Liu, Zude

    2017-09-01

    Facet joint osteoarthritis is considered a consequence of the aging process; however, there is evidence that it may be associated with degenerative changes of other structures. The goal of this study was to investigate the correlation between lumbar multifidus muscle features and facet joint osteoarthritis. This retrospective study included 160 patients who had acute or chronic low back pain and were diagnosed with facet joint osteoarthritis on computed tomography scan. Morphometric parameters, including cross-sectional area, muscle-fat index, and percentage of bilateral multifidus asymmetry at L3-L4, L4-L5, and L5-S1, were evaluated with T2-weighted magnetic resonance imaging. Patients with facet joint osteoarthritis had a smaller cross-sectional area and a higher muscle-fat index than those without facet joint osteoarthritis (P<.001). In multivariate regression analysis, older age and higher muscle-fat index were independently associated with facet joint osteoarthritis at all 3 spinal levels (P<.001). Smaller cross-sectional area was independently associated with facet joint osteoarthritis only at L4-L5 (P=.005). Asymmetry of the bilateral multifidus cross-sectional area was independently associated with facet joint osteoarthritis at L5-S1 (P=.009), but did not seem to be responsible for asymmetric degeneration of the bilateral facet joints. A higher multifidus muscle-fat index was independently associated with facet joint osteoarthritis, and bilateral multifidus size asymmetry was associated with the development of facet joint osteoarthritis at L5-S1. It seems more accurate to consider facet joint osteoarthritis a failure of the whole joint structure, including the paraspinal musculature, rather than simply a failure of the facet joint cartilage. [Orthopedics. 2017; 40(5):e793-e800.]. Copyright 2017, SLACK Incorporated.

  4. Factors affecting results of fluoroscopy-guided facet joint injection: Probable differences in the outcome of treatment between pure facet joint hypertrophy and concomitant diseases.

    PubMed

    Albayrak, Akif; Ozkul, Baris; Balioglu, Mehmet Bulent; Atici, Yunus; Gultekin, Muhammet Zeki; Albayrak, Merih Dilan

    2016-01-01

    Retrospective cohort study. Facet joints are considered a common source of chronic low-back pain. To determine whether pathogens related to the facet joint arthritis have any effect on treatment failure. Facet joint injection was applied to 94 patients treated at our hospital between 2011 and 2012 (mean age 59.5 years; 80 women and 14 men). For the purpose of analysis, the patients were divided into two groups. Patients who only had facet hypertrophy were placed in group A (47 patients, 41 women and 6 men, mean age 55.3 years) and patients who had any additional major pathology to facet hypertrophy were placed in group B (47 patients, 39 women and 8 men, mean age 58.9 years). Injections were applied around the facet joint under surgical conditions utilizing fluoroscopy device guidance. A mixture of methylprednisolone and lidocaine was used as the injection ingredient. In terms of Oswestry Disability Index (ODI) and visual analog scale (VAS) scores, no significant difference was found between preinjection and immediate postinjection values in both groups, and the scores of group A patients were significantly lower (P < 0.005) compared with that of group B patients at the end of the third, sixth, and twelfth month. For low-back pain caused by facet hypertrophy, steroid injection around the facet joint is an effective treatment, but if there is an existing major pathology, it is not as effective.

  5. [CORRELATION OF LUMBAR FACET JOINT DEGENERATION AND SPINE-PELVIC SAGITTAL BALANCE].

    PubMed

    Lo, Xin; Zhang, Bin; Liu, Yuan; Dai, Min

    2015-08-01

    To investigate the relationship between lumbar facet joint degeneration of each segment and spine-pelvic sagittal balance parameters. A retrospective analysis was made the clinical data of 120 patients with lumbar degenerative disease, who accorded with the inclusion criteria between June and November 2014. There were 58 males and 62 females with an average age of 53 years (range, 24-77 years). The disease duration ranged from 3 to 96 months (mean, 6.6 months). Affected segments included L3,4 in 32 cases, L4,5 in 47 cases, and L5, S1 in 52 cases. The CT and X-ray films of the lumbar vertebrae were taken. The facet joint degeneration was graded based on the grading system of Pathria. The spine-pelvic sagittal balance parameters were measured, including lumbar lordosis (LL), upper lumbar lordosis (ULL), lower lumbar lordosis (LLL), pelvic incidence (PI), pelvic tilt (PT), and sacral slope (SS). According to normal range of PI, the patients were divided into 3 groups: group A (PI was less than normal range), group B (PI was within normal range), and group C (PI was more than normal range). The facet joint degeneration was compared; according to the facet joint degeneration degree, the patients were divided into group N (mild degeneration group) and group M (serious degeneration group) to observe the relationship of lumbar facet joint degeneration of each segment and spine-pelvic sagittal balance parameters. At L4,5 and L5, S1, facet joint degeneration showed significant difference among groups A, B, and C (P < 0.05), more serious facet joint degeneration was observed in group C; no significant difference was found in facet joint degeneration at L3,4 (P > 0.05). There was no significant difference in the other spine-pelvic sagittal balance parameters between groups N and M at each segment (P > 0.05) except for PT (P < 0.05). PI of more than normal range may lead to or aggravate lumbar facet joint degeneration at L4,5 and L5, Si; PT and PI are significantly associated

  6. Management of irreducible unilateral facet joint dislocations in subaxial cervical spine: two case reports and a review of the literature.

    PubMed

    Zhou, Yu; Zhou, Zhenyu; Liu, Lifeng; Cao, Xuecheng

    2018-03-21

    Skeletal and soft tissue damage are often associated with unilateral facet dislocations, which undoubtedly lead to instability of the spine and further increase difficulties in cervical reduction. This type of irreducible facet dislocation is usually accompanied with potential catastrophic consequences including neurological deficit and severe disability. Therefore, a consistent and evidence-based treatment plan is imperative. The literature regarding the management of traumatic unilateral locked cervical facet dislocations was reviewed. Two patient cases (a 30-year-old Asian man and a 25-year-old Asian woman) who suffered irreducible cervical facet dislocations were presented. These two patients received surgical treatments including posterior reduction by poking facet joints, adjacent spinous process fixation by wire rope banding, anterior plate fixation, and intervertebral fusion after the failure of skull traction and closed reduction. At the postoperative 24-month follow-up, intervertebral fusion was achieved and our patients' neurological status improved based on the American Spinal Injury Association scale, compared with their preoperative status. Unilateral facet joint dislocations of subaxial cervical spine are difficult to reduce when complicated with posterior facet fractures or ligamentous injury. Magnetic resonance imaging can be beneficial for identifying ventral and dorsal compressive lesions, as well as ligamentous or capsule rupture. The combination of posterior reduction and anterior fixation with fusion has advantages in terms of clinical safety, ease of operation, and less iatrogenic damage.

  7. Subdural empyema following lumbar facet joint injection: An exceeding rare complication.

    PubMed

    Fayeye, Oluwafikayo; Silva, Adikarige Haritha Dulanka; Chavda, Swarupsinh; Furtado, Navin Raoul

    2016-01-01

    Chronic low back pain is extremely common with a life time prevalence estimated at greater than 70%. Facet joint arthrosis is thought to be the causative aetiological substrate in approximately 25% of chronic low back pain cases. Facet joint injection is a routine intervention in the armamentarium for both the diagnostic and therapeutic management of chronic low back pain. In fact, a study by Carrino et al. reported in excess of 94,000 facet joint injection procedures were carried out in the US in 1999. Although generally considered safe, the procedure is not entirely without risk. Complications including bleeding, infection, exacerbation of pain, dural puncture headache, and pneumothorax have been described. We report a rare case of a 47-year-old female patient who developed a left L4/5 facet septic arthrosis with an associated subdural empyema and meningitis following facet joint injection. This case is unique, as to the best of our knowledge no other case of subdural empyema following facet joint injection has been reported in the literature. Furthermore this case serves to highlight the potential serious adverse sequelae of a routine and apparently innocuous intervention. The need for medical practitioners to be alert to and respond rapidly to the infective complications of facet joint injection cannot be understated. Copyright © 2016 Polish Neurological Society. Published by Elsevier Urban & Partner Sp. z o.o. All rights reserved.

  8. Percutaneous Facet Screw Fixation in the Treatment of Symptomatic Recurrent Lumbar Facet Joint Cyst: A New Technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Amoretti, Nicolas, E-mail: amorettinicolas@yahoo.fr; Gallo, Giacomo, E-mail: giacomo.gallo83@gmail.com; Bertrand, Anne-Sophie, E-mail: asbertrand3@hotmail.com

    We present a case of percutaneous treatment of symptomatic recurrent lumbar facet joint cyst resistant to all medical treatments including facet joint steroid injection. Percutaneous transfacet fixation was then performed at L4–L5 level with a cannulated screw using CT and fluoroscopy guidance. The procedure time was 30 min. Using the visual analog scale (VAS), pain decreased from 9.5, preoperatively, to 0 after the procedure. At 6-month follow-up, an asymptomatic cystic recurrence was observed, which further reduced at the 1-year follow-up. Pain remained stable (VAS at 0) during all follow-ups. CT- and fluoroscopy-guided percutaneous cyst rupture associated with facet screw fixation couldmore » be an alternative to surgery in patients suffering from a symptomatic recurrent lumbar facet joint cyst.« less

  9. Uncovertebral joint injury in cervical facet dislocation: the headphones sign.

    PubMed

    Palmieri, Francesco; Cassar-Pullicino, Victor N; Dell'Atti, Claudia; Lalam, Radhesh K; Tins, Bernhard J; Tyrrell, Prudencia N M; McCall, Iain W

    2006-06-01

    The purpose of our study is to demonstrate the uncovertebral mal-alignment as a reliable indirect sign of cervical facet joint dislocation. We examined the uncovertebral axial plane alignment of 12 patients with unilateral and bilateral cervical facet joint dislocation (UCFJD and BCFJD, respectively), comparing its frequency to the reverse hamburger bun sign on CT and MR axial images. Of the seven cases with BCFJD, five clearly demonstrated the diagnostic reverse facet joint hamburger bun sign on CT and MR images, but in two cases this sign was not detectable. In the five cases with UCFJD, four demonstrated the reverse hamburger bun sign on both CT and MRI. In one case the reverse hamburger bun sign was not seen adequately with either image modality, but the facet dislocation was identified on sagittal imaging. The uncovertebral mal-alignment was detected in all 12 cases. Normally, the two components of the uncovertebral joint enjoy a concentric relationship that in the axial plane is reminiscent of the relationship of headphones with the wearer's head. We name this appearance the 'headphones' sign. Radiologists should be aware of the headphones sign as a reliable indicator of facet joint dislocation on axial imaging used in the assessment of cervical spine injuries.

  10. [Feasibility and accuracy of ultrasound-guided methodology in the examination of lumbar spine facet joints].

    PubMed

    Wen, Chuan-Bing; Li, Yong-Zhong; Tang, Qin-Qin; Sun, Lin; Xiao, Hong; Yang, Bang-Xiang; Song, Li; Liu, Hui

    2013-03-01

    To investigate the feasibility, accuracy of B ultrasound in the examination of joint space of lumbar spine facet joints compared with CT scan. Ten healthy adult volunteers were enrolled. The joint space of lumbar facet joints was measured by ultrasound. To identify the spinal levels, the posterior parasagittal sonograms were obtained at levels L1 to S1. The lumbar facet joints were delineated with the help of transverse sonograms at each level. Meanwhile, the lumbar facet joints were evaluated by spiral CT on the same plane, reformatted to 1-mm axial slices. A total of 88 lumbar facet joints from L1 to S1 were clearly visualized in the 10 volunteers. Both ultrasound and CT measurements showed the same average depth and lateral distance of lumbar facet joint space (P > 0.05). The lumbar facet joint space can be accurately demonstrated by ultrasound.

  11. Magnetic resonance-guided focused ultrasound treatment of facet joint pain: summary of preclinical phase

    PubMed Central

    2014-01-01

    Study design A phantom experiment, two thermocouple experiments, three in vivo pig experiments, and a simulated treatment on a healthy human volunteer were conducted to test the feasibility, safety, and efficacy of magnetic resonance-guided focused ultrasound (MRgFUS) for treating facet joint pain. Objective The goal of the current study was to develop a novel method for accurate and safe noninvasive facet joint ablation using MRgFUS. Summary of background data Facet joints are a common source of chronic back pain. Direct facet joint interventions include medial branch nerve ablation and intra-articular injections, which are widely used, but limited in the short and long term. MRgFUS is a breakthrough technology that enables accurate delivery of high-intensity focused ultrasound energy to create a localized temperature rise for tissue ablation, using MR guidance for treatment planning and real-time feedback. Methods We validated the feasibility, safety, and efficacy of MRgFUS for facet joint ablation using the ExAblate 2000® System (InSightec Ltd., Tirat Carmel, Israel) and confirmed the system's ability to ablate the edge of the facet joint and all terminal nerves innervating the joint. A phantom experiment, two thermocouple experiments, three in vivo pig experiments, and a simulated treatment on a healthy human volunteer were conducted. Results The experiments showed that targeting the facet joint with energies of 150–450 J provides controlled and accurate heating at the facet joint edge without penetration to the vertebral body, spinal canal, or root foramina. Treating with reduced diameter of the acoustic beam is recommended since a narrower beam improves access to the targeted areas. Conclusions MRgFUS can safely and effectively target and ablate the facet joint. These results are highly significant, given that this is the first study to demonstrate the potential of MRgFUS to treat facet joint pain. PMID:24921048

  12. Isolation and Characterization of Human Mesenchymal Stem Cells From Facet Joints and Interspinous Ligaments.

    PubMed

    Kristjánsson, Baldur; Limthongkul, Worawat; Yingsakmongkol, Wicharn; Thantiworasit, Pattarawat; Jirathanathornnukul, Napaphat; Honsawek, Sittisak

    2016-01-01

    A descriptive in vitro study on isolation and differentiation of human mesenchymal stem cells (MSCs) derived from the facet joints and interspinous ligaments. To isolate cells from the facet joints and interspinous ligaments and investigate their surface marker profile and differentiation potentials. Lumbar spinal canal stenosis and ossification of the posterior longitudinal ligament are progressive conditions characterized by the hypertrophy and ossification of ligaments and joints within the spinal canal. MSCs are believed to play a role in the advancement of these diseases and the existence of MSCs has been demonstrated within the ligamentum flavum and posterior longitudinal ligament. The aim of this study was to investigate whether these cells could also be found within facet joints and interspinous ligaments. Samples were harvested from 10 patients undergoing spinal surgery. The MSCs from facet joints and interspinous ligaments were isolated using direct tissue explant technique. Cell surface antigen profilings were performed via flow cytometry. Their lineage differentiation potentials were analyzed. The facet joints and interspinous ligaments-derived MSCs have the tri-lineage potential to be differentiated into osteogenic, adipogenic, and chondrogenic cells under appropriate inductions. Flow cytometry analysis revealed both cell lines expressed MSCs markers. Both facet joints and interspinous ligaments-derived MSCs expressed marker genes for osteoblasts, adipocytes, and chondrocytes. The facet joints and interspinous ligaments may provide alternative sources of MSCs for tissue engineering applications. The facet joints and interspinous ligaments-derived MSCs are part of the microenvironment of the human ligaments of the spinal column and might play a crucial role in the development and progression of degenerative spine conditions.

  13. Temporal gene expression profiling of the rat knee joint capsule during immobilization-induced joint contractures.

    PubMed

    Wong, Kayleigh; Sun, Fangui; Trudel, Guy; Sebastiani, Paola; Laneuville, Odette

    2015-05-26

    Contractures of the knee joint cause disability and handicap. Recovering range of motion is recognized by arthritic patients as their preference for improved health outcome secondary only to pain management. Clinical and experimental studies provide evidence that the posterior knee capsule prevents the knee from achieving full extension. This study was undertaken to investigate the dynamic changes of the joint capsule transcriptome during the progression of knee joint contractures induced by immobilization. We performed a microarray analysis of genes expressed in the posterior knee joint capsule following induction of a flexion contracture by rigidly immobilizing the rat knee joint over a time-course of 16 weeks. Fold changes of expression values were measured and co-expressed genes were identified by clustering based on time-series analysis. Genes associated with immobilization were further analyzed to reveal pathways and biological significance and validated by immunohistochemistry on sagittal sections of knee joints. Changes in expression with a minimum of 1.5 fold changes were dominated by a decrease in expression for 7732 probe sets occurring at week 8 while the expression of 2251 probe sets increased. Clusters of genes with similar profiles of expression included a total of 162 genes displaying at least a 2 fold change compared to week 1. Functional analysis revealed ontology categories corresponding to triglyceride metabolism, extracellular matrix and muscle contraction. The altered expression of selected genes involved in the triglyceride biosynthesis pathway; AGPAT-9, and of the genes P4HB and HSP47, both involved in collagen synthesis, was confirmed by immunohistochemistry. Gene expression in the knee joint capsule was sensitive to joint immobility and provided insights into molecular mechanisms relevant to the pathophysiology of knee flexion contractures. Capsule responses to immobilization was dynamic and characterized by modulation of at least three

  14. Cervical facet force analysis after disc replacement versus fusion.

    PubMed

    Patel, Vikas V; Wuthrich, Zachary R; McGilvray, Kirk C; Lafleur, Matthew C; Lindley, Emily M; Sun, Derrick; Puttlitz, Christian M

    2017-05-01

    Cervical total disc replacement was developed to preserve motion and reduce adjacent-level degeneration relative to fusion, yet concerns remain that total disc replacement will lead to altered facet joint loading and long-term facet joint arthrosis. This study is intended to evaluate changes in facet contact force, pressure and surface area at the treated and superior adjacent levels before and after discectomy, disc replacement, and fusion. Ten fresh-frozen human cadaveric cervical spines were potted from C2 to C7 with pressure sensors placed into the facet joints of C3-C4 and C4-C5 via slits in the facet capsules. Moments were applied to the specimens to produce axial rotation, lateral bending and extension. Facet contact force and pressure were measured at both levels for intact, discectomy at C4-C5, disc replacement with ProDisc-C (Synthes Spine, West Chester, Pennsylvania, USA) at C4-C5, and anterior discectomy and fusion with Cervical Spine Locking Plate (Synthes Spine, West Chester, Pennsylvania, USA) at C4-C5. Facet contact area was calculated from the force and pressure measurements. An analysis of variance was used to determine significant differences with P-values <0.05 indicating significance. Facet contact force was elevated at the treated level under extension following both discectomy and disc replacement, while facet contact pressure and area were relatively unchanged. Facet contact force and area were decreased at the treated level following fusion for all three loading conditions. Total disc replacement preserved facet contact force for all scenarios except extension at the treated level, highlighting the importance of the anterior disco-ligamentous complex. This could promote treated-level facet joint disease. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. The Relationship Between Osteoarthritis of the Lumbar Facet Joints and Lumbosacropelvic Morphology.

    PubMed

    Sahin, Mehmet Sukru; Ergün, Adviye; Aslan, Akın

    2015-10-01

    Cross-sectional study. To investigate the relation between lumbosacropelvic morphology and the presence and degree of facet joint degeneration. Osteoarthritis of the facet joints is one of the most common degenerative changes in the spine. It is considered to be formed secondary to repetitive stress or trauma and spinal deformity with secondary overload. The cause(s) of facet joints osteoarthritis, however, have not been clearly identified. Abdominal computed tomography (CT) images of 723 patients which were taken between the years 2010 and 2014 were evaluated retrospectively. Patients with prior lumbar spinal surgery, serious congenital anomalies on CT, incomplete or complete lumbosacral transition, severe scoliosis, were excluded from the study. To eliminate the age- and sex-related differences in spinopelvic morphology, a study group was formed of the remaining subjects by including patients from a specific age group (30-35 yr) and same sex (females). For each patient the presence and grade of facet joint degeneration was investigated. In addition, pelvic incidence (PI), sacral slope and the angles of L1-L5 lumbar lordosis, sacral table, L5 vertebra posterior, and sacral kyphosis were measured for each patient. Sacral slope, sacral kyphosis, and L1-L5 lumbar lordosis angle were significantly higher in patients with osteoarthritic compared with normal subjects (P = 0.015, P = 0.018, P = 0.016). L5 vertebra posterior and sacral table angle were found to be significantly lower in patients with osteoarthritic than in normal subjects (P = 0.019, P = 0.007). The degree of facet joint degeneration was noticed to increase parallel to the decrease in the sacral table angle and L5 vertebra posterior angle, and to the increase in the L1-L5 lumbar lordosis, PI, and sacral slope. A close relation exists between the presence and degree of degeneration in the facet joint and lumbosacral pelvic morphology. Prevalence and degree of the degeneration in facet joint increases as

  16. Radiological and Radionuclide Imaging of Degenerative Disease of the Facet Joints

    PubMed Central

    Shur, Natalie; Corrigan, Alexis; Agrawal, Kanhaiyalal; Desai, Amidevi; Gnanasegaran, Gopinath

    2015-01-01

    The facet joint has been increasingly implicated as a potential source of lower back pain. Diagnosis can be challenging as there is not a direct correlation between facet joint disease and clinical or radiological features. The purpose of this article is to review the diagnosis, treatment, and current imaging modality options in the context of degenerative facet joint disease. We describe each modality in turn with a pictorial review using current evidence. Newer hybrid imaging techniques such as single photon emission computed tomography/computed tomography (SPECT/CT) provide additional information relative to the historic gold standard magnetic resonance imaging. The diagnostic benefits of SPECT/CT include precise localization and characterization of spinal lesions and improved diagnosis for lower back pain. It may have a role in selecting patients for local therapeutic injections, as well as guiding their location with increased precision. PMID:26170560

  17. Quantitative in vivo MRI evaluation of lumbar facet joints and intervertebral discs using axial T2 mapping.

    PubMed

    Stelzeneder, David; Messner, Alina; Vlychou, Marianna; Welsch, Goetz H; Scheurecker, Georg; Goed, Sabine; Pieber, Karin; Pflueger, Verena; Friedrich, Klaus M; Trattnig, Siegfried

    2011-11-01

    To assess the feasibility of T2 mapping of lumbar facet joints and intervertebral discs in a single imaging slab and to compare the findings with morphological grading. Sixty lumbar spine segments from 10 low back pain patients and 5 healthy volunteers were examined by axial T2 mapping and morphological MRI at 3.0 Tesla. Regions of interest were drawn on a single slice for the facet joints and the intervertebral discs (nucleus pulposus, anterior and posterior annulus fibrosus). The Weishaupt grading was used for facet joints and the Pfirrmann score was used for morphological disc grading ("normal" vs. "abnormal" discs). The inter-rater agreement was excellent for the facet joint T2 evaluation (r = 0.85), but poor for the morphological Weishaupt grading (kappa = 0.15). The preliminary results show similar facet joint T2 values in segments with normal and abnormal Pfirrmann scores. There was no difference in mean T2 values between facet joints in different Weishaupt grading groups. Facet joint T2 values showed a weak correlation with T2 values of the posterior annulus (r = 0.32) This study demonstrates the feasibility of a combined T2 mapping approach for the facet joints and intervertebral discs using a single axial slab.

  18. The comparison of measurement between ultrasound and computed tomography for abnormal degenerative facet joints: A STROBE-compliant article.

    PubMed

    Shi, Wen; Tian, Dan; Liu, Da; Yin, Jing; Huang, Ying

    2017-08-01

    Besides the study on examining facet joints of lumbar spine by ultrasound in normal population, there has not been any related report about examining normal facet joints of lumbar spine by ultrasound so far. This study was aimed to explore the feasibility of ultrasound assessment of lumber spine facet joints by comparing ultrasound measure values of normal and degenerative lumber spine facet joints, and by comparing measure values of ultrasound and computed tomography (CT) of degenerative lumber spine facet joints.This study included 15 patients who had chronic low back pain because of degenerative change in lumbar vertebrae, and 19 volunteers who did not have low back pain or pain in the lower limb. The ultrasound measure values (height [H] and width [W]) of normal and degenerative lumber spine facet joints were compared. And the differentiation between measure values (H and W) of ultrasound and CT of degenerative lumber spine facet joints was also analyzed.The ultrasound clearly showed abnormal facet joints lesion, which was characterized by hyperostosis on the edge of joints, bone destruction under joints, and thinner or thicker articular cartilage. There were significant differences between the ultrasound measure values of the normal (H: 1.26 ± 0.03 cm, W: 0.18 ± 0.01 cm) and abnormal facet joints (H: 1.43 ± 0.05 cm, W: 0.15 ± 0.02 cm) (all P < .05). However, there were no significant differences between the measure values of the ultrasound (H: 1.43 ± 0.17 cm, W: 0.15 ± 0.03 cm) and CT (H: 1.42 ± 0.16, W: 0.14 ± 0.03) of the degenerative lumber spine facet joints (all P > .05).Ultrasound can clearly show the structure of facet joints of lumbar spine. It is precise and feasible to assess facet joints of lumbar spine by ultrasound. This study has important significance for the diagnosis of lumbar facet joint degeneration.

  19. In vivo facet joint loading of the canine lumbar spine.

    PubMed

    Buttermann, G R; Schendel, M J; Kahmann, R D; Lewis, J L; Bradford, D S

    1992-01-01

    This study describes a technique to measure in vivo loads and the resultant load-contact locations in the facet joint of the canine lumbar spine. The technique is a modification of a previously described in vitro method that used calibrated surface strains of the lateral aspect of the right L3 cranial articular process. In the present study, strains were measured during various in vivo static and dynamic activities 3 days after strain gage implantation. The in vivo recording technique and its errors, which depend on the location of the applied facet loads, is described. The results of applying the technique to five dogs gave the following results. Relative resultant contact load locations on the facet tended to be in the central and caudal portion of the facet in extension activities, central and cranial in standing, and cranial and ventral in flexion or right-turning activities. Right-turning contact locations were ventral and cranial to left-turning locations. Resultant load locations at peak loading during walking were in the central region of the facet, whereas resultant load locations at minimum loading during walking were relatively craniad. This resultant load-contact location during a walk gait cycle typically migrated in an arc with a displacement of 4 mm from minimum to maximum loading. Static tests resulted in a range of facet loads of 0 N in flexion and lying to 185 N for two-legged standing erect, and stand resulted in facet loads of 26 +/- 15 N (mean +/- standard deviation [SD]). Dynamic tests resulted in peak facet loads ranging from 55 N while walking erect to 170 N for climbing up stairs. Maximum walk facet loads were 107 +/- 27 N. The technique is applicable to in vivo studies of a canine facet joint osteoarthritis model and may be useful for establishing an understanding of the biomechanics of low-back pain.

  20. Correlations between the feature of sagittal spinopelvic alignment and facet joint degeneration: a retrospective study.

    PubMed

    Lv, Xin; Liu, Yuan; Zhou, Song; Wang, Qiang; Gu, Houyun; Fu, Xiaoxing; Ding, Yi; Zhang, Bin; Dai, Min

    2016-08-15

    Sagittal spinopelvic alignment changes associated with degenerative facet joint arthritis have been assessed in a few studies. It has been documented that patients with facet joint degeneration have higher pelvic incidence, but the relationship between facet joint degeneration and other sagittal spinopelvic alignment parameters is still disputed. Our purpose was to evaluate the correlation between the features of sagittal spinopelvic alignment and facet joint degeneration. Imaging data of 140 individuals were retrospectively analysed. Lumbar lordosis, pelvic tilt (PT), pelvic incidence (PI), sacral slope, and height of the lumbar intervertebral disc were measured on lumbar X-ray plates. Grades of facet joint degeneration were evaluated from the L2 to S1 on CT scans. Spearman's rank correlation coefficient and Student's t-test were used for statistical analyses, and a P-value <0.05 was considered statistically significant. PI was positively associated with degeneration of the facet joint at lower lumbar levels (p < 0.001 r = 0.50 at L5/S1 and P = 0.002 r = 0.25 at L4/5). A significant increase of PT was found in the severe degeneration group compared with the mild degeneration group: 22.0° vs 15.7°, P = 0.034 at L2/3;21.4°vs 15.1°, P = 0.006 at L3/4; 21.0° vs 13.5°, P = 0.000 at L4/5; 20.8° vs 12.1°, P = 0.000 at L5/S1. Our results indicate that a high PI is a predisposing factor for facet joint degeneration at the lower lumbar spine, and that severe facet joint degeneration may accompany with greater PT at lumbar spine.

  1. Chiropractic management of capsulitis and synovitis of the temporomandibular joint.

    PubMed

    Curl, D D; Stanwood, G

    1993-01-01

    Localized inflammatory conditions (eg, synovitis and capsulitis) of the temporomandibular joint are commonly seen in clinical practice. Regardless of their frequency of occurrence, these conditions must be differentially diagnosed from conditions that also may cause pain in the temporomandibular joint region. Capsulitis or synovitis should be considered if such pain is present and historical, physical, and laboratory findings do not indicate a referred pain phenomena or systemic, tumorous, or infectious involvement. This article reviews the clinical characteristics, etiology, physical examination methods, treatment, and prognosis for capsulitis and synovitis, and three cases that illustrate these conditions are reported.

  2. Incidence of inadvertent intra-articular lumbar facet joint injection during fluoroscopically guided interlaminar epidural steroid injection.

    PubMed

    Huang, Ambrose J; Palmer, William E

    2012-02-01

    To determine the incidence of inadvertent lumbar facet joint injection during an interlaminar epidural steroid injection (ESI). A total of 686 interlaminar lumbar ESIs were performed from January 1, 2009 to December 31, 2009. Archived images from these cases were retrospectively reviewed on the PACS. Positive cases of inadvertent lumbar facet joint injection were identified by the characteristic sigmoid-shaped contrast pattern projecting over the posterior elements on the lateral view and/or ovoid contrast projecting over the facet joints on the anteroposterior (AP) view. Eight positive events were identified (1.2%). There was no statistically significant gender or lumbar level predilection. In 3/8 of the positive cases (37.5%), the inadvertent facet joint injection was recognized by the operator. The needle was repositioned as a result, and contrast within the posterior epidural space was documented by the end of the procedure. In 5/8 of the positive cases (62.5%), the patients reported an immediate decrease in the presenting pain. The incidence of inadvertent lumbar facet joint injection during an interlaminar epidural steroid injection is low. Recognizing the imaging features of this event permits the operator to redirect the needle tip into the epidural space and/or identify the facet joint(s) as a source of the patient's presenting pain.

  3. Morphological changes in the cervical intervertebral foramen dimensions with unilateral facet joint dislocation.

    PubMed

    Ebraheim, Nabil A; Liu, Jiayong; Ramineni, Satheesh K; Liu, Xiaochen; Xie, Joe; Hartman, Ryan G; Goel, Vijay K

    2009-11-01

    Many investigators have conducted studies to determine the biomechanics, causes, complications and treatment of unilateral facet joint dislocation in the cervical spine. However, there is no quantitative data available on morphological changes in the intervertebral foramen of the cervical spine following unilateral facet joint dislocation. These data are important to understand the cause of neurological compromise following unilateral facet joint dislocation. Eight embalmed human cadaver cervical spine specimens ranging from level C1-T1 were used. The nerve roots of these specimens at C5-C6 level were marked by wrapping a 0.12mm diameter wire around them. Unilateral facet dislocation at C5-C6 level was simulated by serially sectioning the corresponding ligamentous structures. A CT scan of the specimens was obtained before and after the dislocation was simulated. A sagittal plane through the centre of the pedicle and facet joint was constructed and used for measurement. The height and area of the intervertebral foramen, the facet joint space, nerve root diameter and area, and vertebral alignment both before and after dislocation were evaluated. The intervertebral foramen area changed from 50.72+/-0.88mm(2) to 67.82+/-4.77mm(2) on the non-dislocated side and from 41.39+/-1.11mm(2) to 113.77+/-5.65mm(2) on the dislocated side. The foraminal heights changed from 9.02+/-0.30mm to 10.52+/-0.50mm on the non-dislocated side and 10.43+/-0.50mm to 17.04+/-0.96mm on the dislocated side. The facet space area in the sagittal plane changed from 6.80+/-0.80mm(2) to 40.02+/-1.40mm(2) on the non-dislocated side. The C-5 anterior displacement showed a great change from 0mm to 5.40+/-0.24mm on the non-dislocated side and from 0mm to 3.42+/-0.20mm on the dislocated side. Neither of the nerve roots on either side showed a significant change in size. The lack of change in nerve root area indicates that the associated nerve injury with unilateral facet joint dislocation is probably due

  4. [Lumbosacral facet joint stabilization: Mc Bride technique].

    PubMed

    Martínez, Ernesto De León; García, J Antonio Vázquez; Castillo, Pablo Atlitec

    2008-01-01

    We carried out a retrospective study of the clinical results of lumbosacral decompression with Mc Bride technique, in treatment of degenerative unstable lumbar stenosis. Three hundred and forty patients (180 male) were treated during May 1996 to May 2003. Mean age at surgery was 47 years old (22-85) with 3 to 8 years of follow up. All patients fulfilled clinical and image criteria for chronic lumbar pain due to degenerative lumbar stenosis and segmental instability that did not improve with conservative treatment. We found very good results in 114 patients (33.5%), good in 203 patients (59.7%), regular in 16 patients (4.7%), and poor in 6 patients (2%). The Mc Bride technique is based in interlaminar distraction and permits managing lumbar stenosis and arthrodesis of an unstable segment simultaneously. It diminishes compression in the foramen, maintains a position in extension, reduces facet joints subluxation and eliminates the strategic point of intervertebral mobility in facet joints. It allows immediate stabilization and later fusion by placing a bone block.

  5. Contribution of facet joints, axial compression, and composition to human lumbar disc torsion mechanics.

    PubMed

    Bezci, Semih E; Eleswarapu, Ananth; Klineberg, Eric O; O'Connell, Grace D

    2018-02-12

    Stresses applied to the spinal column are distributed between the intervertebral disc and facet joints. Structural and compositional changes alter stress distributions within the disc and between the disc and facet joints. These changes influence the mechanical properties of the disc joint, including its stiffness, range of motion, and energy absorption under quasi-static and dynamic loads. There have been few studies evaluating the role of facet joints in torsion. Furthermore, the relationship between biochemical composition and torsion mechanics is not well understood. Therefore, the first objective of this study was to investigate the role of facet joints in torsion mechanics of healthy and degenerated human lumbar discs under a wide range of compressive preloads. To achieve this, each disc was tested under four different compressive preloads (300-1200 N) with and without facet joints. The second objective was to develop a quantitative structure-function relationship between tissue composition and torsion mechanics. Facet joints have a significant contribution to disc torsional stiffness (∼60%) and viscoelasticity, regardless of the magnitude of axial compression. The findings from this study demonstrate that annulus fibrosus GAG content plays an important role in disc torsion mechanics. A decrease in GAG content with degeneration reduced torsion mechanics by more than an order of magnitude, while collagen content did not significantly influence disc torsion mechanics. The biochemical-mechanical and compression-torsion relationships reported in this study allow for better comparison between studies that use discs of varying levels of degeneration or testing protocols and provide important design criteria for biological repair strategies. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  6. Intraarticular Pulsed Radiofrequency to Treat Refractory Lumbar Facet Joint Pain in Patients with Low Back Pain.

    PubMed

    Chang, Min Cheol; Cho, Yun-Woo; Ahn, Da Hyun; Do, Kyung Hee

    2018-04-01

    Many treatment techniques have been used for refractory lumbar facet joint pain; however, their efficacy has been controversial. In this study, we investigated the clinical efficacy and safety of intra-articular pulsed radiofrequency for the treatment of refractory lumbar facet joint pain in patients with low back pain. Twenty patients with refractory lumbar facet joint pain were recruited, and each patient was treated via intra-articular pulsed radiofrequency. The treatment effects were measured with a numerical rating scale, and the technical accuracy of intra-articular pulsed radiofrequency treatment was evaluated independently by 2 radiologists. Any adverse events or complications also were checked. We performed intra-articular pulsed radiofrequency treatment at 48 levels of the lumbar facet joints in 20 patients (5 men and 15 women; mean age, 64.50 ± 10.65 years) with refractory lumbar facet joint pain. Pain scores were significantly reduced at 1 month, 3 months, and 6 months after treatment (P < 0.05). The face validity revealed good intraarticular pulsed radiofrequency results in all 20 patients, without any serious adverse effects. Treatment using intra-articular pulsed radiofrequency is an alternative to other techniques in patients with refractory lumbar facet joint pain. Copyright © 2018 Elsevier Inc. All rights reserved.

  7. Cystic adventitial degeneration: ectopic ganglia from adjacent joint capsules.

    PubMed

    Ortmann, J; Widmer, M K; Gretener, S; Do, D D; Willenberg, T; Daliri, A; Baumgartner, I

    2009-11-01

    Cystic adventitial degeneration is a rare non-atherosclerotic cause of peripheral arterial occlusive disease, mainly seen in young men without other evidence of vascular disease. Diagnosis will be established by clinical findings and by ultrasound or angiography and can be treated by excision or enucleation of the affected arterial segment or by percutaneous ultrasound-guided aspiration. However, the etiology of adventitial cysts remains unknown. We report a case of cystic adventitial degeneration showing a connection between the joint capsule and the adventitial cyst, supporting the theory that cystic adventitial degeneration may represent ectopic ganglia from adjacent joint capsules.

  8. Intra-articular nerve growth factor regulates development, but not maintenance, of injury-induced facet joint pain & spinal neuronal hypersensitivity.

    PubMed

    Kras, J V; Kartha, S; Winkelstein, B A

    2015-11-01

    The objective of the current study is to define whether intra-articular nerve growth factor (NGF), an inflammatory mediator that contributes to osteoarthritic pain, is necessary and sufficient for the development or maintenance of injury-induced facet joint pain and its concomitant spinal neuronal hyperexcitability. Male Holtzman rats underwent painful cervical facet joint distraction (FJD) or sham procedures. Mechanical hyperalgesia was assessed in the forepaws, and NGF expression was quantified in the C6/C7 facet joint. An anti-NGF antibody was administered intra-articularly in additional rats immediately or 1 day following facet distraction or sham procedures to block intra-articular NGF and test its contribution to initiation and/or maintenance of facet joint pain and spinal neuronal hyperexcitability. NGF was injected into the bilateral C6/C7 facet joints in separate rats to determine if NGF alone is sufficient to induce these behavioral and neuronal responses. NGF expression increases in the cervical facet joint in association with behavioral sensitivity after that joint's mechanical injury. Intra-articular application of anti-NGF immediately after a joint distraction prevents the development of both injury-induced pain and hyperexcitability of spinal neurons. Yet, intra-articular anti-NGF applied after pain has developed does not attenuate either behavioral or neuronal hyperexcitability. Intra-articular NGF administered to the facet in naïve rats also induces behavioral hypersensitivity and spinal neuronal hyperexcitability. Findings demonstrate that NGF in the facet joint contributes to the development of injury-induced joint pain. Localized blocking of NGF signaling in the joint may provide potential treatment for joint pain. Copyright © 2015 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  9. Facet Joint Osteoarthritis Affects Spinal Segmental Motion in Degenerative Spondylolisthesis.

    PubMed

    Kitanaka, Shigeyuki; Takatori, Ryota; Arai, Yuji; Nagae, Masateru; Tonomura, Hitoshi; Mikami, Yasuo; Inoue, Nozomu; Ogura, Taku; Fujiwara, Hiroyoshi; Kubo, Toshikazu

    2018-06-15

    This is a retrospective clinical case series (case-control study). To clarify the influence of facet joint osteoarthritis (FJOA) on the pathology of degenerative spondylolisthesis (DS) using in vivo 3-dimensional image analysis. There are no radical treatments to prevent progression of DS in patients with lumbar spinal canal stenosis associated with DS. Therefore, an effective treatment method based on the pathology of DS should be developed. In total, 50 patients with lumbar spinal canal stenosis involving L4/5 who underwent dynamic computed tomography were divided into 2 groups: with DS [spondylolisthesis (Sp) group; 12 male, 14 female; mean age, 74 y]; and without DS (non-Sp group; 15 male, 9 female; mean age, 70 y). Degeneration of the intervertebral disk and FJOA at L4/5 were evaluated using magnetic resonance imaging. Disk and intervertebral foramen heights, the distance between the craniocaudal edges of the facet joint, and the interspinous distance were measured on dynamic computed tomographic images. Also, in vivo 3-dimensional segmental motion was evaluated using the volume merge method. There were no significant differences in degenerative findings for the intervertebral disk; however, progressive FJOA was detected in the Sp group. Dynamic changes in the distance between the craniocaudal edges of the facet joints were significantly larger in the Sp group. In this study, progressive FJOA and larger segmental motion in the distance between the craniocaudal edges of the facet joints were found in the Sp group. We clarified for the first time that DS involves ligament laxity due to FJOA that affects spinal segmental motion in vivo. We consider that a treatment method based on FJOA would be useful for treating patients with DS. Level IV.

  10. INTRA-ARTICULAR NERVE GROWTH FACTOR REGULATES DEVELOPMENT, BUT NOT MAINTENANCE, OF INJURY-INDUCED FACET JOINT PAIN & SPINAL NEURONAL HYPERSENSITIVITY

    PubMed Central

    Kras, Jeffrey V.; Kartha, Sonia; Winkelstein, Beth A.

    2015-01-01

    Objective The objective of the current study is to define whether intra-articular nerve growth factor (NGF), an inflammatory mediator that contributes to osteoarthritic pain, is necessary and sufficient for the development or maintenance of injury-induced facet joint pain and its concomitant spinal neuronal hyperexcitability. Method Male Holtzman rats underwent painful cervical facet joint distraction or sham procedures. Mechanical hyperalgesia was assessed in the forepaws, and NGF expression was quantified in the C6/C7 facet joint. An anti-NGF antibody was administered intra-articularly in additional rats immediately or 1 day following facet distraction or sham procedures to block intra-articular NGF and test its contribution to initiation and/or maintenance of facet joint pain and spinal neuronal hyperexcitability. NGF was injected into the bilateral C6/C7 facet joints in separate rats to determine if NGF alone is sufficient to induce these behavioral and neuronal responses. Results NGF expression increases in the cervical facet joint in association with behavioral sensitivity after that joint’s mechanical injury. Intra-articular application of anti-NGF immediately after a joint distraction prevents the development of both injury-induced pain and hyperexcitability of spinal neurons. Yet, intra-articular anti-NGF applied after pain has developed does not attenuate either behavioral or neuronal hyperexcitability. Intra-articular NGF administered to the facet in naïve rats also induces behavioral hypersensitivity and spinal neuronal hyperexcitability. Conclusion Findings demonstrate that NGF in the facet joint contributes to the development of injury-induced joint pain. Localized blocking of NGF signaling in the joint may provide potential treatment for joint pain. PMID:26521746

  11. Qualitative and quantitative assessment of degeneration of cervical intervertebral discs and facet joints.

    PubMed

    Walraevens, Joris; Liu, Baoge; Meersschaert, Joke; Demaerel, Philippe; Delye, Hans; Depreitere, Bart; Vander Sloten, Jos; Goffin, Jan

    2009-03-01

    Degeneration of intervertebral discs and facet joints is one of the most frequently encountered spinal disorders. In order to describe and quantify degeneration and evaluate a possible relationship between degeneration and biomechanical parameters, e.g., the intervertebral range of motion and intradiscal pressure, a scoring system for degeneration is mandatory. However, few scoring systems for the assessment of degeneration of the cervical spine exist. Therefore, two separate objective scoring systems to qualitatively and quantitatively assess the degree of cervical intervertebral disc and facet joint degeneration were developed and validated. The scoring system for cervical disc degeneration consists of three variables which are individually scored on neutral lateral radiographs: "height loss" (0-4 points), "anterior osteophytes" (0-3 points) and "endplate sclerosis" (0-2 points). The scoring system for facet joint degeneration consists of four variables which are individually scored on neutral computed tomography scans: "hypertrophy" (0-2 points), "osteophytes" (0-1 point), "irregularity" on the articular surface (0-1 point) and "joint space narrowing" (0-1 point). Each variable contributes with varying importance to the overall degeneration score (max 9 points for the scoring system of cervical disc degeneration and max 5 points for facet joint degeneration). Degeneration of 20 discs and facet joints of 20 patients was blindly assessed by four raters: two neurosurgeons (one senior and one junior) and two radiologists (one senior and one junior), firstly based on first subjective impression and secondly using the scoring systems. Measurement errors and inter- and intra-rater agreement were determined. The measurement error of the scoring system for cervical disc degeneration was 11.1 versus 17.9% of the subjective impression results. This scoring system showed excellent intra-rater agreement (ICC = 0.86, 0.75-0.93) and excellent inter-rater agreement (ICC = 0

  12. Changes in biomechanical properties of glenohumeral joint capsules with adhesive capsulitis by repeated capsule-preserving hydraulic distensions with saline solution and corticosteroid.

    PubMed

    Koh, Eun S; Chung, Sun G; Kim, Tae Uk; Kim, Hee Chan

    2012-12-01

    To investigate whether capsule-preserving hydraulic distension with saline solution and corticosteroid for adhesive capsulitis induces biomechanical alterations in glenohumeral joint capsules along with clinical improvements. A case series. University outpatient clinic of physical medicine and rehabilitation. Eighteen patients with unilateral adhesive capsulitis. INTERVENTION AND MAIN OUTCOME MEASUREMENTS: Three hydraulic distensions with saline solution and corticosteroid were performed with 1-month intervals. To avoid rupturing capsules, all distensions were monitored by using real-time pressure-volume curves. Stiffness, maximal volume capacity, and pressure at the maximal volume capacity of the capsule were measured at each intervention. Clinical parameters, such as pain and range of motion, were recorded before, 3 days after, and 1 month after each distension. Stiffness decreased (47.6 ± 27.1 mm Hg/mL to 31.7 ± 18.4 mm Hg/mL to 24.2 ± 14.0 mm Hg/mL, mean SD) and maximal volume capacity increased (18.8 ± 7.3 mL to 20.5 ± 7.5 mL to 24.2 ± 7.0 mL, mean SD) significantly (P = .001 for both) at each repeated hydraulic distension. Pressure at the maximal volume capacity tended to decrease, but the decrements were not statistically significant (P = .662). The clinical parameters were significantly improved throughout and 1 month after the 3 repeat procedures (P < .05 for all). Capsule-preserving hydraulic distension changed the biomechanical properties of the glenohumeral joint capsule, lessening the stiffness and enlarging the volume capacity. These alterations were accompanied by improved range of motion and relief of pain. Repeated capsule-preserving hydraulic distension with saline solution and corticosteroid would be useful to treat adhesive capsulitis and to evaluate the treatment results. Copyright © 2012 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  13. Vertebral rotatory subluxation in degenerative scoliosis: facet joint tropism is related.

    PubMed

    Bao, Hongda; Zhu, Feng; Liu, Zhen; Bentley, Mark; Mao, Saihu; Zhu, Zezhang; Ding, Yitao; Qiu, Yong

    2014-12-15

    A cross-sectional study. To identify facet tropism as one of the possible risk factors leading to vertebral rotatory subluxation (VRS). VRS has been considered as one of the prognostic factors for degenerative scoliosis. Although several risk factors of VRS, including age and Cobb angle, have been investigated, few studies exist that have evaluated the correlation between VRS and anatomical structures of the vertebral column. This retrospective study recruited 23 patients diagnosed with degenerative lumbar scoliosis with VRS and 20 patients with degenerative scoliosis without VRS. The lateral translation on coronal radiographs was measured and 5 mm was used as the cutoff value to define rotatory subluxation. Computed tomographic scans for facet joints were made for all lumbar levels. The difference between right and left facet angles was recorded as ΔFA. Facet tropism was defined as a difference between the bilateral facet angles of more than 10°. In this study, VRS was most commonly found at the L3-L4 level (49%) and, with decreasing frequency at L2-L3 (24%), L4-L5 (20%), and L1-L2 (7%). On the convex side of the main curve, face joints at levels with VRS were more coronally oriented compared with those at levels without VRS (41.64° ± 11.65° vs. 36.30° ± 10.99°, P = 0.034). ΔFA was also significantly different between levels with and without VRS (P = 0.005). A strong correlation was found between ΔFA and lateral translation, with a coefficient of 0.33 (P < 0.001). In addition, ΔFA and a larger Cobb angle were found to be significantly associated with VRS based on binary regression analysis, with an odds ratio of 4.68 and 2.14, respectively. Facet tropism was more significantly observed at levels with VRS. On the convex side of the main curve, facet joints at levels with VRS were more coronally oriented. A larger Cobb angle and severe facet tropism in degenerative scoliosis should be considered to be related to VRS.

  14. Effect of facet joint injection versus systemic steroids in low back pain: a randomized controlled trial.

    PubMed

    Ribeiro, Luiza Helena; Furtado, Rita Nely Vilar; Konai, Monique Sayuri; Andreo, Ana Beatriz; Rosenfeld, Andre; Natour, Jamil

    2013-11-01

    Randomized clinical trial. To compare the effectiveness of facet joint injection versus systemic steroid in patients with a diagnosis of facet joint syndrome. The term facet joint syndrome has been used to define back pain originating from the facet joints. Treatment is mainly conservative, although interventions, including intra-articular injections and medial branch nerve blocks are used to manage facet-mediated pain. Several studies have evaluated the effectiveness of these interventions. Results of facet joint injection, however, are conflicting. Sixty subjects with a diagnosis of facet joint syndrome were enrolled in the study. They were randomized into experimental and control groups. The experimental group was administered with intra-articular injection of 6 lumbar facet joints with triamcinolone hexacetonide; the control group was administered with triamcinolone acetonide intramuscular injection of 6 lumbar paravertebral points. Visits were taken at baseline and at 1, 4, 12, and 24 weeks after interventions. Outcome measures were used: pain visual analogue scale, pain visual analogue scale during extension of the spine, Likert scale, improvement percentage scale, Roland-Morris, 36-Item Short Form Health Survey, and accountability of medications taken.Homogeneity was tested using the Student t, Pearson χ, and Mann-Whitney tests. Analysis of variance was used to analyze differences in the groups over time and the Student t test to analyze differences between groups at each time evaluation. The groups were similar at baseline. Comparisons between the groups showed, in analysis of variance analysis, an improvement in the experimental group regarding diclofenac intake and quality of life, in the "role physical" profile, assessed by 36-Item Short Form Health Survey.In the analysis at each time point, an improvement in the experimental group was also found in the Roland-Morris questionnaire, in the improvement percentage scale and in the response to treatment

  15. Effects of glucosamine on proteoglycan loss by tendon, ligament and joint capsule explant cultures.

    PubMed

    Ilic, M Z; Martinac, B; Samiric, T; Handley, C J

    2008-12-01

    To investigate the effect of glucosamine on the loss of newly synthesized radiolabeled large and small proteoglycans by bovine tendon, ligament and joint capsule. The kinetics of loss of (35)S-labeled large and small proteoglycans from explant cultures of tendon, ligament and joint capsule treated with 10mM glucosamine was investigated over a 10-day culture period. The kinetics of loss of (35)S-labeled small proteoglycans and the formation of free [(35)S]sulfate were determined for the last 10 days of a 15-day culture period. The proteoglycan core proteins were analyzed by gel electrophoresis followed by fluorography. The metabolism of tendon, ligament and joint capsule explants exposed to 10mM glucosamine was evaluated by incorporation of [(3)H]serine and [(35)S]sulfate into protein and glycosaminoglycans, respectively. Glucosamine at 10mM stimulated the loss of small proteoglycans from ligament explant cultures. This was due to the increased loss of both macromolecular and free [(35)S]sulfate to the medium indicating that glucosamine affected the release of small proteoglycans as well as their intracellular degradation. The degradation pattern of small proteoglycans in ligament was not affected by glucosamine. In contrast, glucosamine did not have an effect on the loss of large or small proteoglycans from tendon and joint capsule or large proteoglycans from ligament explant cultures. The metabolism of cells in tendon, ligament and joint capsule was not impaired by the presence of 10mM glucosamine. Glucosamine stimulated the loss of small proteoglycans from ligament but did not have an effect on small proteoglycan catabolism in joint capsule and tendon or large proteoglycan catabolism in ligament, tendon or synovial capsule. The consequences of glucosamine therapy at clinically relevant concentrations on proteoglycan catabolism in joint fibrous connective tissues need to be further assessed in an animal model.

  16. Indices of Paraspinal Muscles Degeneration: Reliability and Association With Facet Joint Osteoarthritis: Feasibility Study.

    PubMed

    Kalichman, Leonid; Klindukhov, Alexander; Li, Ling; Linov, Lina

    2016-11-01

    A reliability and cross-sectional observational study. To introduce a scoring system for visible fat infiltration in paraspinal muscles; to evaluate intertester and intratester reliability of this system and its relationship with indices of muscle density; to evaluate the association between indices of paraspinal muscle degeneration and facet joint osteoarthritis. Current evidence suggests that the paraspinal muscles degeneration is associated with low back pain, facet joint osteoarthritis, spondylolisthesis, and degenerative disc disease. However, the evaluation of paraspinal muscles on computed tomography is not radiological routine, probably because of absence of simple and reliable indices of paraspinal degeneration. One hundred fifty consecutive computed tomography scans of the lower back (N=75) or abdomen (N=75) were evaluated. Mean radiographic density (in Hounsfield units) and SD of the density of multifidus and erector spinae were evaluated at the L4-L5 spinal level. A new index of muscle degeneration, radiographic density ratio=muscle density/SD of density, was calculated. To evaluate the visible fat infiltration in paraspinal muscles, we proposed a 3-graded scoring system. The prevalence of facet joint osteoarthritis was also evaluated. Intraclass correlation and κ statistics were used to evaluate inter-rater and intra-rater reliability. Logistic regression examined the association between paraspinal muscle indices and facet joint osteoarthritis. Intra-rater reliability for fat infiltration score (κ) ranged between 0.87 and 0.92; inter-rater reliability between 0.70 and 0.81. Intra-rater reliability (intraclass correlation) for mean density of paraspinal muscles ranged between 0.96 and 0.99, inter-rater reliability between 0.95 and 0.99; SD intra-rater reliability ranged between 0.82 and 0.91, inter-rater reliability between 0.80 and 0.89. Significant associations (P<0.01) were found between facet joint osteoarthritis, fat infiltration score, and

  17. Facet joint geometry and intervertebral disk degeneration in the L5-S1 region of the vertebral column in German Shepherd dogs.

    PubMed

    Seiler, Gabriela S; Häni, Hansjürg; Busato, André R; Lang, Johann

    2002-01-01

    To evaluate the possible association between facet joint geometry and intervertebral disk degeneration in German Shepherd Dogs. 25 German Shepherd Dogs and 11 control dogs of similar body weight and condition. Facet joint angles in the caudal portion of the lumbar region of the vertebral column (L5-S1) were measured by use of computed tomography, and the intervertebral discs were evaluated microscopically. The relationship between facet joint geometry and disk degeneration was evaluated by use of statistical methods. German Shepherd Dogs had significantly more facet joint tropism than control dogs, but an association with disk degeneration was not found. However, German Shepherd Dogs had a different facet joint conformation, with more sagittally oriented facet joints at L5-L6 and L6-L7 and a larger angle difference between the lumbar and lumbosacral facet joints, compared with control dogs. A large difference between facet joint angles at L6-L7 and L7-S1 in German Shepherd Dogs may be associated with the frequent occurrence of lumbosacral disk degeneration in this breed.

  18. Lumbar Facet Joint Motion in Patients with Degenerative Disc Disease at Affected and Adjacent Levels

    PubMed Central

    Li, Weishi; Wang, Shaobai; Xia, Qun; Passias, Peter; Kozanek, Michal; Wood, Kirkham; Li, Guoan

    2013-01-01

    Study Design Controlled laboratory study. Objective To evaluate the effect of lumbar degenerative disc diseases (DDDs) on motion of the facet joints during functional weight-bearing activities. Summary of Background Data It has been suggested that DDD adversely affects the biomechanical behavior of the facet joints. Altered facet joint motion, in turn, has been thought to associate with various types of lumbar spine pathology including facet degeneration, neural impingement, and DDD progression. However, to date, no data have been reported on the motion patterns of the lumbar facet joint in DDD patients. Methods Ten symptomatic patients of DDD at L4–S1 were studied. Each participant underwent magnetic resonance images to obtain three-dimensional models of the lumbar vertebrae (L2–S1) and dual fluoroscopic imaging during three characteristic trunk motions: left-right torsion, left-right bending, and flexion-extension. In vivo positions of the vertebrae were reproduced by matching the three-dimensional models of the vertebrae to their outlines on the fluoroscopic images. The kinematics of the facet joints and the ranges of motion (ROMs) were compared with a group of healthy participants reported in a previous study. Results In facet joints of the DDD patients, there was no predominant axis of rotation and no difference in ROMs was found between the different levels. During left-right torsion, the ROMs were similar between the DDD patients and the healthy participants. During left-right bending, the rotation around mediolateral axis at L4–L5, in the DDD patients, was significantly larger than that of the healthy participants. During flexion-extension, the rotations around anterioposterior axis at L4–L5 and around craniocaudal axis at the adjacent level (L3–L4), in the DDD patients, were also significantly larger, whereas the rotation around mediolateral axis at both L2–L3 and L3–L4 levels in the DDD patients were significantly smaller than those of the

  19. Physiotherapy and lumbar facet joint injections as a combination treatment for chronic low back pain. A narrative review of lumbar facet joint injections, lumbar spinal mobilizations, soft tissue massage and lower back mobility exercises.

    PubMed

    Chambers, Hannah

    2013-06-01

    The aim of this study was to summarize the available evidence on lumbar facet joint injections and the physiotherapy treatments, land-based lower back mobility exercise, soft tissue massage and lumbar spinal mobilizations for chronic low back pain (CLBP). The plausibility of physiotherapy and lumbar facet joint injections as a combination treatment is discussed. Using a systematic process, an online electronic search was performed using key words utilizing all available databases and hand searching reference lists. Using a critical appraisal tool from the Critical Appraisal Skills Programme (CASP), the literature was screened to include primary research. The main aspects of the research were summarized. The evidence for lumbar facet joint injections suggests an overall short-term positive effect on CLBP. Land-based lower back mobility exercise and soft tissue massage appear to have a positive effect on CLBP in the short term and possibly in the longer term. There is insufficient evidence to draw conclusions for lumbar spinal mobilizations. The review indicates that lumbar facet joint injections create a short period when pain is reduced. Physiotherapy treatments including land-based lower back mobility exercise and soft tissue massage may be of benefit during this time to improve the longer-term outcomes of patients with CLBP. It is not possible to make generalizations or firm conclusions. The current review highlights the need for further research. A randomized controlled trial is recommended to assess the impact of physiotherapy in combination with lumbar facet joint injections on CLBP. Copyright © 2013 John Wiley & Sons, Ltd.

  20. THE PROSTAGLANDIN E2 RECEPTOR, EP2, IS UPREGULATED IN THE DRG AFTER PAINFUL CERVICAL FACET JOINT INJURY IN THE RAT

    PubMed Central

    Kras, Jeffrey V.; Dong, Ling; Winkelstein, Beth A.

    2012-01-01

    Study Design This study implemented immunohistochemistry to assay prostaglandin E2 (PGE2) receptor EP2 expression in the dorsal root ganglion (DRG) of rats after painful cervical facet joint injury. Objective The objective of this study was to identify if inflammatory cascades are induced in association with cervical facet joint distraction-induced pain by investigating the time course of EP2 expression in the DRG. Summary of Background Data The cervical facet joint is a common source of neck pain and non-physiological stretch of the facet capsular ligament can initiate pain from the facet joint via mechanical injury. PGE2 levels are elevated in painful inflamed and arthritic joints, and PGE2 sensitizes joint afferents to mechanical stimulation. Although in vitro studies suggest the EP2 receptor subtype contributes to painful joint disease the EP2 response has not been investigated for any association with painful mechanical joint injury. Methods Separate groups of male Holtzman rats underwent either a painful cervical facet joint distraction injury or sham procedure. Bilateral forepaw mechanical allodynia was assessed, and immunohistochemical techniques were used to quantify EP2 expression in the DRG at days 1 and 7. Results Facet joint distraction induced mechanical allodynia that was significant (p<0.024) at all time points. Painful joint injury also significantly elevated total EP2 expression in the DRG at day 1 (p=0.009), which was maintained also at day 7 (p<0.001). Neuronal expression of EP2 in the DRG was only increased over sham levels at day 1 (p=0.013). Conclusions Painful cervical facet joint distraction induces an immediate and sustained increase of EP2 expression in the DRG, implicating peripheral inflammation in the initiation and maintenance of facet joint pain. The transient increase in neuronal EP2 suggests, as in other painful joint conditions, that after joint injury non-neuronal cells may migrate to the DRG, some of which likely express EP2

  1. Talocalcaneal Joint Middle Facet Coalition Resection With Interposition of a Juvenile Hyaline Cartilage Graft.

    PubMed

    Tower, Dyane E; Wood, Ryan W; Vaardahl, Michael D

    2015-01-01

    Talocalcaneal joint middle facet coalition is the most common tarsal coalition, occurring in ≤2% of the population. Fewer than 50% of involved feet obtain lasting relief of symptoms after nonoperative treatment, and surgical intervention is commonly used to relieve symptoms, increase the range of motion, improve function, reconstruct concomitant pes planovalgus, and prevent future arthrosis from occurring at the surrounding joints. Several approaches to surgical intervention are available for patients with middle facet coalitions, ranging from resection to hindfoot arthrodesis. We present a series of 4 cases, in 3 adolescent patients, of talocalcaneal joint middle facet coalition resection with interposition of a particulate juvenile hyaline cartilaginous allograft (DeNovo(®) NT Natural Tissue Graft, Zimmer, Inc., Warsaw, IN). With a mean follow-up period of 42.8 ± 2.9 (range 41 to 47) months, the 3 adolescent patients in the present series were doing well with improved subtalar joint motion and decreased pain, and 1 foot showed no bony regrowth on a follow-up computed tomography scan. The use of a particulate juvenile hyaline cartilaginous allograft as interposition material after talocalcaneal middle facet coalition resection combined with adjunct procedures to address concomitant pes planovalgus resulted in good short-term outcomes in 4 feet in 3 adolescent patients. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  2. Evaluation of Water Content in Lumbar Intervertebral Discs and Facet Joints Before and After Physiological Loading Using T2 Mapping MRI.

    PubMed

    Yamabe, Daisuke; Murakami, Hideki; Chokan, Kou; Endo, Hirooki; Oikawa, Ryosuke; Sawamura, Shoitsu; Doita, Minoru

    2017-12-15

    T2 mapping was used to quantify the water content of lumbar spine intervertebral discs (IVDs) and facet joints before and after physiological loading. The aim of this study was to clarify the interaction between lumbar spine IVD and facet joints as load-bearing structures by measuring the water content of their matrix after physiological loading using T2 mapping magnetic resonance imaging (MRI). To date, few reports have functionally evaluated lumbar spine IVD and facet joints, and their interaction in vivo. T2 mapping may help detect changes in the water content of IVD and articular cartilage of facet joints before and after physiological loading, thereby enabling the evaluation of changes in interacted water retention between IVD and facet joints. Twenty asymptomatic volunteers (10 female and 10 male volunteers; mean age, 19.3 years; age range, 19-20 years) underwent MRI before and after physiological loading such as lumbar flexion, extension, and rotation. Each IVD from L1/2 to L5/S1 was sliced at center of the disc space, and the T2 value was measured at the nucleus pulposus (NP), anterior annulus fibrosus (AF), posterior AF, and bilateral facet joints. In the NP, T2 values significantly decreased after exercise at every lumbar spinal level. In the anterior AF, there were no significant differences in T2 values at any level. In the posterior AF, T2 values significantly increased only at L4/5. In the bilateral facet joints, T2 values significantly decreased after exercise at every level. There was a significant decrease in the water content of facet joints and the NP at every lumbar spinal level after dynamic loading by physical lumbar exercise. These changes appear to play an important and interactional role in the maintenance of the interstitial matrix in the IVD NP and cartilage in the facet joint. 3.

  3. Audit of conservative management of chronic low back pain in a secondary care setting--part I: facet joint and sacroiliac joint interventions.

    PubMed

    Chakraverty, Robin; Dias, Richard

    2004-12-01

    The work of a chronic back pain service in secondary care in the West Midlands is reported. The service offers acupuncture, spinal injection procedures, osteopathy and a range of other interventions for patients whose back pain has not responded to conservative management. This section of the report focuses on injection procedures for lumbar facet joint and sacroiliac joint pain, which have been shown to be the cause of chronic low back pain in 16-40% and 13-19% of patients respectively. Diagnosis relies on the use of intra-articular or sensory nerve block injections with local anaesthetic. Possible treatments following diagnosis include intra-articular corticosteroid, radiofrequency denervation (for facet joint pain) or ligament prolotherapy injections (for sacroiliac joint pain). The results of several hospital audits are reported. At six month follow up, 50% of 38 patients undergoing radiofrequency denervation following diagnostic blocks for facet joint pain had improved by more than 50%, compared to 29% of 34 patients treated with intra-articular corticosteroid injection. Sixty three per cent of 19 patients undergoing prolotherapy following diagnostic block injection for sacroiliac joint pain had improved at six months, compared to 33% of 33 who had intra-articular corticosteroid. Both radiofrequency denervation and sacroiliac prolotherapy showed good long-term outcomes at one year.

  4. Symptomatic lumbar facet joint cysts treated by CT-guided intracystic and intra-articular steroid injections.

    PubMed

    Amoretti, Nicolas; Huwart, Laurent; Foti, Pauline; Boileau, Pascal; Amoretti, Marie-Eve; Pellegrin, Amelie; Marcy, Pierre-Yves; Hauger, Olivier

    2012-12-01

    To evaluate percutaneous computed tomography (CT)-guided intracystic and intra-articular steroid injections for the treatment of lumbar facet joint cyst causing radicular pain. A single-centre prospective study involving 120 consecutive patients with symptomatic lumbar facet joint cyst-induced radicular pain was done (72 women, 48 men). The average age was 68.2 years (52-84). Patients were treated by percutaneous CT-guided intracystic and intra-articular steroid injections. The clinical course of nerve root pain was evaluated after 1 day, and 1, 3 and 6 months, with long-term follow-up after 12 months. Patient follow-ups in our series show supportive results: within 120 patients, 54% of patients were satisfied with a long-lasting result from the first intra-cystic and intra-articular steroid injections (n = 65), while 20.8% were satisfied with a long-lasting result from a second intervention. Combining these two results shows that 75% of patients were satisfied with a long-lasting result. Our results showed that percutaneous treatment of vertebral lumbar facet joint cysts by double injections is an effective and economic therapeutic technical management among 75% of our patients. Thus we recommend that it should be considered as a first choice of treatment. Lumbar facet joint cysts are a common feature of back and radicular pain. They may be treated effectively by interventional radiologists using CT guidance. Percutaneous treatment using double injections can save surgery in 75% of patients.

  5. [effectiveness of open reduction and internal fixation without opening joint capsule on tibial plateau fracture].

    PubMed

    Chen, Qi; Xu, Xiaofeng; Huang, Yonghui; Cao, Xingbing; Meng, Chen; Cao, Xueshu; Wei, Changbao

    2014-12-01

    To introduce the surgery method to reset and fix tibial plateau fracture without opening joint capsule, and evaluate the safety and effectiveness of this method. Between July 2011 and July 2013, 51 patients with tibial plateau fracture accorded with the inclusion criteria were included. All of 51 patients, 17 cases underwent open reduction and internal fixation without opening joint capsule in trial group, and 34 cases underwent traditional surgery method in control group. There was no significant difference in gender, age, cause of injury, time from injury to admission, side of injury, and types of fracture between 2 groups (P > 0.05). The operation time, intraoperative blood loss, incision length, incision healing, and fracture healing were compared between 2 groups. The tibial-femoral angle and collapse of joint surface were measured on X-ray film. At last follow-up, joint function was evaluated with Hospital for Special Surgery (HSS) knee function scale. The intraoperative blood loss in trial group was significantly less than that in control group (P < 0.05). The incision length in trial group was significantly shorter than that in control group (P < 0.05). Difference was not significant in operation time and the rate of incision healing between 2 groups (P > 0.05). The patients were followed up 12-30 months (mean, 20.4 months) in trial group and 12-31 months (mean, 18.2 months) in control group. X-ray films indicated that all cases in 2 groups obtained fracture healing; there was no significant difference in the fracture healing time between 2 groups (t=1.382, P=0.173). On X-ray films, difference was not significant in tibial-femoral angle and collapse of joint surface between 2 groups (P > 0.05). HSS score of the knee in trial group was significantly higher than that of control group (t=3.161, P=0.003). It can reduce the intraoperative blood loss and shorten the incision length to use open reduction and internal fixation without opening joint capsule for

  6. Can extra-articular strains be used to measure facet contact forces in the lumbar spine? An in-vitro biomechanical study.

    PubMed

    Zhu, Q A; Park, Y B; Sjovold, S G; Niosi, C A; Wilson, D C; Cripton, P A; Oxland, T R

    2008-02-01

    Experimental measurement of the load-bearing patterns of the facet joints in the lumbar spine remains a challenge, thereby limiting the assessment of facet joint function under various surgical conditions and the validation of computational models. The extra-articular strain (EAS) technique, a non-invasive measurement of the contact load, has been used for unilateral facet joints but does not incorporate strain coupling, i.e. ipsilateral EASs due to forces on the contralateral facet joint. The objectives of the present study were to establish a bilateral model for facet contact force measurement using the EAS technique and to determine its effectiveness in measuring these facet joint contact forces during three-dimensional flexibility tests in the lumbar spine. Specific goals were to assess the accuracy and repeatability of the technique and to assess the effect of soft-tissue artefacts. In the accuracy and repeatability tests, ten uniaxial strain gauges were bonded to the external surface of the inferior facets of L3 of ten fresh lumbar spine specimens. Two pressure-sensitive sensors (Tekscan) were inserted into the joints after the capsules were cut. Facet contact forces were measured with the EAS and Tekscan techniques for each specimen in flexion, extension, axial rotation, and lateral bending under a +/- 7.5 N m pure moment. Four of the ten specimens were tested five times in axial rotation and extension for repeatability. These same specimens were disarticulated and known forces were applied across the facet joint using a manual probe (direct accuracy) and a materials-testing system (disarticulated accuracy). In soft-tissue artefact tests, a separate set of six lumbar spine specimens was used to document the virtual facet joint contact forces during a flexibility test following removal of the superior facet processes. Linear strain coupling was observed in all specimens. The average peak facet joint contact forces during flexibility testing was greatest in

  7. Intra-articular injection of collagenase induced experimental osteoarthritis of the lumbar facet joint in rats.

    PubMed

    Yeh, Tsu-Te; Wen, Zhi-Hong; Lee, Herng-Sheng; Lee, Chian-Her; Yang, Zhi; Jean, Yen-Hsuan; Wu, Shing-Sheng; Nimni, Marcel E; Han, Bo

    2008-05-01

    We aimed to establish an animal model to investigate primary osteoarthritis of the lumbar facet joints after collagenase injection in rats and its effects on chondrocyte apoptosis. We hypothesized that osteoarthritic-like changes would be induced by collagenase injection and that apoptosis of chondrocytes would increase. Collagenase (1, 10, or 50 U) or saline (control) was injected into the lumbar facet joints. The histology and histochemistry of cartilage, synovium, and subchondral bone were examined at 1, 3, and 6 weeks after surgery. Apoptotic cells induced by 1 U of collagenase were quantified using the terminal deoxynucleotidyl transferase-mediated dUTP nick end labelling (TUNEL) assay. Degeneration of the cartilage and changes to the synovium and subchondral bone were dependent on both the doses of collagenase and the time after surgery. There were significantly more apoptotic chondrocytes in collagenase-treated joints than in control (P < 0.001 at 1 and 3 weeks and P < 0.05 at 6 weeks). Thus, lumbar facet joints subjected to collagenase developed osteoarthritic-like changes that could be quantified and compared. This model provides a useful tool for further study on the effects of compounds that have the potential to inhibit enzyme-associated damage to cartilage.

  8. Intra-articular injection of collagenase induced experimental osteoarthritis of the lumbar facet joint in rats

    PubMed Central

    Yeh, Tsu-Te; Wen, Zhi-Hong; Lee, Herng-Sheng; Lee, Chian-Her; Yang, Zhi; Jean, Yen-Hsuan; Nimni, Marcel E.; Han, Bo

    2008-01-01

    We aimed to establish an animal model to investigate primary osteoarthritis of the lumbar facet joints after collagenase injection in rats and its effects on chondrocyte apoptosis. We hypothesized that osteoarthritic-like changes would be induced by collagenase injection and that apoptosis of chondrocytes would increase. Collagenase (1, 10, or 50 U) or saline (control) was injected into the lumbar facet joints. The histology and histochemistry of cartilage, synovium, and subchondral bone were examined at 1, 3, and 6 weeks after surgery. Apoptotic cells induced by 1 U of collagenase were quantified using the terminal deoxynucleotidyl transferase-mediated dUTP nick end labelling (TUNEL) assay. Degeneration of the cartilage and changes to the synovium and subchondral bone were dependent on both the doses of collagenase and the time after surgery. There were significantly more apoptotic chondrocytes in collagenase-treated joints than in control (P < 0.001 at 1 and 3 weeks and P < 0.05 at 6 weeks). Thus, lumbar facet joints subjected to collagenase developed osteoarthritic-like changes that could be quantified and compared. This model provides a useful tool for further study on the effects of compounds that have the potential to inhibit enzyme-associated damage to cartilage. PMID:18224353

  9. A new technique to treat facet joint pain with pulsed radiofrequency.

    PubMed

    Schianchi, Pietro Martino

    2015-02-01

    Facet joint pain affects 5% to 15% of the population with low back pain and the prevalence increases with age due to progression of arthritis. While conservative treatments are often unsuccessful, the scientific evidence on minimally invasive therapies such as intra-articular steroid infiltration and continuous and pulsed radiofrequency (PRF) of the medial branches is contradictory. Since PRF has recently been reported to successfully treat joint pain, a new application of this method is proposed for facetogenic lumbar pain via an intra-articular subcapsular approach. Here we reported two cases with successful treatment. A 71-year-old patient presented because of persisting pain in the left gluteal region radiating to the lateral thigh and calf when standing. Anti-inflammatory drugs produced only short-lasting insufficient relief. A 52-year-old employee was admitted in June 2012 because of axial lower lumbar pain with intermittent diffuse radiation to the right lower extremity that worsened during walking and lying down despite receiving analgesics and physiotherapy. A new approach to treat lumbar facet joint pain with PRF is simple to perform and without serious complications. In view of the good long-lasting results obtained with the two reported cases, randomized control trials are necessary to validate this new approach.

  10. Joint FACET: the Canada-Netherlands initiative to study multisensor data fusion systems

    NASA Astrophysics Data System (ADS)

    Bosse, Eloi; Theil, Arne; Roy, Jean; Huizing, Albert G.; van Aartsen, Simon

    1998-09-01

    This paper presents the progress of a collaborative effort between Canada and The Netherlands in analyzing multi-sensor data fusion systems, e.g. for potential application to their respective frigates. In view of the overlapping interest in studying and comparing applicability and performance and advanced state-of-the-art Multi-Sensor Data FUsion (MSDF) techniques, the two research establishments involved have decided to join their efforts in the development of MSDF testbeds. This resulted in the so-called Joint-FACET, a highly modular and flexible series of applications that is capable of processing both real and synthetic input data. Joint-FACET allows the user to create and edit test scenarios with multiple ships, sensor and targets, generate realistic sensor outputs, and to process these outputs with a variety of MSDF algorithms. These MSDF algorithms can also be tested using typical experimental data collected during live military exercises.

  11. Biomechanical evaluation of the impact of various facet joint lesions on the primary stability of anterior plate fixation in cervical dislocation injuries: a cadaver study: Laboratory investigation.

    PubMed

    Oberkircher, Ludwig; Born, Sebastian; Struewer, Johannes; Bliemel, Christopher; Buecking, Benjamin; Wack, Christina; Bergmann, Martin; Ruchholtz, Steffen; Krüger, Antonio

    2014-10-01

    Injuries of the subaxial cervical spine including facet joints and posterior ligaments are common. Potential surgical treatments consist of anterior, posterior, or anterior-posterior fixation. Because each approach has its advantages and disadvantages, the best treatment is debated. This biomechanical cadaver study compared the effect of different facet joint injuries on primary stability following anterior plate fixation. Fractures and plate fixation were performed on 15 fresh-frozen intact cervical spines (C3-T1). To simulate a translation-rotation injury in all groups, complete ligament rupture and facet dislocation were simulated by dissecting the entire posterior and anterior ligament complex between C-4 and C-5. In the first group, the facet joints were left intact. In the second group, one facet joint between C-4 and C-5 was removed and the other side was left intact. In the third group, both facet joints between C-4 and C-5 were removed. The authors next performed single-level anterior discectomy and interbody grafting using bone material from the respective thoracic vertebral bodies. An anterior cervical locking plate was used for fixation. Continuous loading was performed using a servohydraulic test bench at 2 N/sec. The mean load failure was measured when the implant failed. In the group in which both facet joints were intact, the mean load failure was 174.6 ± 46.93 N. The mean load failure in the second group where only one facet joint was removed was 127.8 ± 22.83 N. In the group in which both facet joints were removed, the mean load failure was 73.42 ± 32.51 N. There was a significant difference between the first group (both facet joints intact) and the third group (both facet joints removed) (p < 0.05, Kruskal-Wallis test). In this cadaver study, primary stability of anterior plate fixation for dislocation injuries of the subaxial cervical spine was dependent on the presence of the facet joints. If the bone in one or both facet joints is damaged

  12. Evaluation of Lumbar Facet Joint Nerve Blocks in Managing Chronic Low Back Pain: A Randomized, Double-Blind, Controlled Trial with a 2-Year Follow-Up

    PubMed Central

    Manchikanti, Laxmaiah; Singh, Vijay; Falco, Frank J.E.; Cash, Kimberly A.; Pampati, Vidyasagar

    2010-01-01

    Study Design: A randomized, double-blind, controlled trial. Objective: To determine the clinical effectiveness of therapeutic lumbar facet joint nerve blocks with or without steroids in managing chronic low back pain of facet joint origin. Summary of Background Data: Lumbar facet joints have been shown as the source of chronic pain in 21% to 41% of low back patients with an average prevalence of 31% utilizing controlled comparative local anesthetic blocks. Intraarticular injections, medial branch blocks, and radiofrequency neurotomy of lumbar facet joint nerves have been described in the alleviation of chronic low back pain of facet joint origin. Methods: The study included 120 patients with 60 patients in each group with local anesthetic alone or local anesthetic and steroids. The inclusion criteria was based upon a positive response to diagnostic controlled, comparative local anesthetic lumbar facet joint blocks. Outcome measures included the numeric rating scale (NRS), Oswestry Disability Index (ODI), opioid intake, and work status, at baseline, 3, 6, 12, 18, and 24 months. Results: Significant improvement with significant pain relief of ≥ 50% and functional improvement of ≥ 40% were observed in 85% in Group 1, and 90% in Group II, at 2-year follow-up. The patients in the study experienced significant pain relief for 82 to 84 weeks of 104 weeks, requiring approximately 5 to 6 treatments with an average relief of 19 weeks per episode of treatment. Conclusions: Therapeutic lumbar facet joint nerve blocks, with or without steroids, may provide a management option for chronic function-limiting low back pain of facet joint origin. PMID:20567613

  13. A New Technique for the Treatment of Lumbar Facet Joint Syndrome Using Intra-articular Injection with Autologous Platelet Rich Plasma.

    PubMed

    Wu, Jiuping; Du, Zhenwu; Lv, Yang; Zhang, Jun; Xiong, Wei; Wang, Ruiqiang; Liu, Rui; Zhang, Guizhen; Liu, Qinyi

    2016-01-01

    Lumbar facet joint syndrome is currently suggested to be a main source of axial low back pain, and a large portion of axial low back pain is caused by disorders in lumbar facet joints. Intra-articular injection is one of the most common treatment methods in the early clinical application. Therefore, we attempt to seek a new injectable material, autologous platelet rich plasma (PRP), to treat lumbar facet syndrome, as well as to assess its therapeutic effectiveness and safety. A prospective clinic evaluation. The outpatient clinic of a single academic medical center. Total 19 patients with lumbar facet joint syndrome (8 men, 11 women; mean ages: 52.53 ± 6.79 years, range: 38 - 62 years) were enrolled to receive lumbar facet joint injection with autologous PRP under x-ray fluoroscopic control. Patients were followed up immediately, at one week, one month, 2 months, and 3 months following treatment, and the elements of this analysis included low back pain visual analogue scale (VAS) at rest and during flexion, Roland-Morris Disability Questionnaire (RMQ), Oswestry Disability Index (ODI), and modified MacNab criteria for the pain relief. All the 19 patients completed the intra-articular injections with autologous PRP successfully. At one week after treatment, low back pain reduced significantly compared with prior to treatment both at rest and during flexion. The outcomes were assessed as "good" or "excellent" for 9 patients (47.37%) immediately after treatment, 14 patients (73.68%) at one week, 15 patients (78.95%) at one month, 15 patients (78.95%) at 2 months, and 15 patients (78.95%) at 3 months. Statistically significant differences were observed based on RMQ and a more than 10% improvement in lumbar functional capacity was observed based on ODI between pre-treatment and post-treatment. In addition, there were no severe relevant complications during the whole process of injection and follow-up period. A control group and the curative effect observations with

  14. Ceramic debris in hip prosthesis: correlation between synovial fluid and joint capsule.

    PubMed

    De Pasquale, Dalila; Stea, Susanna; Beraudi, Alina; Montesi, Monica; Squarzoni, Stefano; Toni, Aldo

    2013-05-01

    Detection of ceramic particles in synovial fluids allows early diagnosis of ceramic damage, but there is no evidence of a relationship between ceramic debris in the articular space and in the joint capsule. The aim of the present study is to verify if the particles isolated in the synovial fluid are comparable with those stored in the capsular tissue. Twenty-one patients were enrolled. Both synovial fluid and capsular samples were collected during revision surgery and ceramic particles were isolated and analyzed by scanning electron microscopy and energy-dispersive X-ray microanalysis. It resulted a significant correlation between the samples couples (18 out of 21). This study confirms that the synovial fluid analysis can give a clear definition of the presence of particles in the joint capsule. Copyright © 2013 Elsevier Inc. All rights reserved.

  15. CT-Guided Transfacet Pedicle Screw Fixation in Facet Joint Syndrome: A Novel Approach

    PubMed Central

    Manfré, Luigi

    2014-01-01

    Summary Axial microinstability secondary to disc degeneration and consequent chronic facet joint syndrome (CFJS) is a well-known pathological entity, usually responsible for low back pain (LBP). Although posterior lumbar fixation (PIF) has been widely used for lumbar spine instability and LBP, complications related to wrong screw introduction, perineural scars and extensive muscle dissection leading to muscle dysfunction have been described. Radiofrequency ablation (RFA) of facet joints zygapophyseal nerves conventionally used for pain treatment fails in approximately 21% of patients. We investigated a “covert-surgery” minimal invasive technique to treat local spinal instability and LBP, using a novel fully CT-guided approach in patients with axial instability complicated by CFJS resistant to radioablation, by introducing direct fully or partially threaded transfacet screws (transfacet fixation - TFF), to acquire solid arthrodesis, reducing instability and LBP. The CT-guided procedure was well tolerated by all patients in simple analogue sedation, and mean operative time was approximately 45 minutes. All eight patients treated underwent clinical and CT study follow-up at two months, revealing LBP disappearance in six patients, and a significant reduction of lumbar pain in two. In conclusion, CT-guided TFF is a fast and safe technique when facet posterior fixation is needed. PMID:25363265

  16. Contrast Dispersion Pattern and Efficacy of Corticosteroid at the Glenohumeral Joint in Adhesive Capsulitis.

    PubMed

    Kim, Sang Jun; Choi, Yu Seong

    2015-01-01

    Corticosteroid injection has a wide range of success in adhesive capsulitis but the reason for this has not yet been explained. We hypothesized that this difference might be due to the distribution of the corticosteroids injected into the joint cavity because particulate steroid deposits in the capsule and will not be moved over time by shoulder motion. The purpose of this study is to determine whether the therapeutic efficacy of particulate corticosteroid injection into the glenohumeral joint differs according to the dispersion pattern. Prospective evaluation. Outpatient clinics at a tertiary university hospital. Seventy-two patients diagnosed as having adhesive capsulitis received a corticosteroid injection at the glenohumeral joint. The posterior capsule and the subscapular bursa were selected as dispersion sites and the dispersion of contrast dye was expressed as a ratio (%). Two weeks and 3 months after the injection clinical improvement ("not improved," "slightly improved," "much improved"), numeric rating scale (NRS), and passive range of motions (PROM) were evaluated. The dispersion of the contrast dye was compared according to the clinical improvements by an analysis of variance test. Pearson correlation test was done to find the relationship between PROM and the dispersion and between change of NRS and the dispersion. The distribution in the subscapular area was 30.0% in the "much improved" group, 22.0% in the "slightly improved" group, and 37.1% in the "no improvement" group which was not significantly different (P = 0.179). Correlations between changes of NRS and the dye distribution were not statistically significant (P = 0.429 at 2 weeks and P = 0.629 at 3 months). The change of passive external rotation 3 months after the injection was significantly correlated with the dye distribution (P = 0.035). Because of diverse pathologic findings in adhesive capsulitis, further studies will be needed to address the effect of the dye distribution on the pain

  17. Lumbar disc degeneration was not related to spine and hip bone mineral densities in Chinese: facet joint osteoarthritis may confound the association.

    PubMed

    Pan, Jianjiang; Lu, Xuan; Yang, Ge; Han, Yongmei; Tong, Xiang; Wang, Yue

    2017-12-01

    A sample of 512 Chinese was studied and we observed that greater disc degeneration on MRI was associated with greater spine DXA BMD. Yet, this association may be confounded by facet joint osteoarthritis. BMD may not be a risk factor for lumbar disc degeneration in Chinese. Evidence suggested that lumbar vertebral bone and intervertebral disc interact with each other in multiple ways. The current paper aims to determine the association between bone mineral density (BMD) and lumbar disc degeneration using a sample of Chinese. We studied 165 patients with back disorders and 347 general subjects from China. All subjects had lumbar spine magnetic resonance (MR) imaging and dual- energy X-ray absorptiometry (DXA) spine BMD studies, and a subset of general subjects had additional hip BMD measurements. On T2-weighted MR images, Pfirrmann score was used to evaluate the degree of lumbar disc degeneration and facet joint osteoarthritis was assessed as none, slight-moderate, and severe. Regression analyses were used to examine the associations between lumbar and hip BMD and disc degeneration, adjusting for age, gender, body mass index (BMI), lumbar region, and facet joint osteoarthritis. Greater facet joint osteoarthritis was associated with greater spine BMD (P < 0.01) in both patients and general subjects. For general subjects, greater spine BMD was associated with severe disc degeneration, controlling for age, gender, BMI, and lumbar region. When facet joint osteoarthritis entered the regression model, however, greater spine BMD was associated with greater facet joint osteoarthritis (P < 0.01) but not greater disc degeneration (P > 0.05). No statistical association was observed between spine BMD and lumbar disc degeneration in patients with back disorders (P > 0.05), and between hip BMD and disc degeneration in general subjects (P > 0.05). BMD may not be a risk factor for lumbar disc degeneration in Chinese. Facet joint osteoarthritis inflates DXA spine BMD

  18. Bony ankylosis of the facet joint of the cervical spine in rheumatoid arthritis: Its characteristics and relationship to the clinical findings.

    PubMed

    Iizuka, Haku; Iizuka, Yoichi; Okamura, Koichi; Yonemoto, Yukio; Mieda, Tokue; Takagishi, Kenji

    2017-09-01

    The purpose of this study was to clarify the characteristics of bony ankylosis of the facet joint of the cervical spine in rheumatoid arthritis (RA) patients who required cervical spine surgery, and its relationship to the clinical findings. Eighty consecutive RA patients with cervical spine disorder who received initial surgery were reviewed. The occurrence of bony ankylosis of the facet joint of the cervical spine was investigated using computed tomography (CT) before surgery. We also evaluated the severity of neurological symptoms and the plain wrist radiographs taken before surgery; furthermore, we evaluated each patient's medical history for total knee arthroplasty (TKA) or hip arthroplasty (THA). The preoperative CT imaging demonstrated bony ankylosis of the facet joint of the cervical spine in 45 facet levels of 19 cases (BA + group). In all patients, responsible instability or stenosis was demonstrated just caudal or on the cranial side of those bony ankylosis. Before surgery, the BA + group included significantly more patients showing severe cervical myelopathy (p < 0.05), and significantly more cases showing progressed ankylosis in the wrist joint bilaterally (p < 0.01). There were also significantly more patients who received two or more TKA or THA before the cervical spine surgery in the BA + group (p < 0.01). Bony ankylosis of the facet joint of the cervical spine may be a risk factor of instability or stenosis at the adjacent disc level and severe cervical myelopathy. Furthermore, its ankylosis was demonstrated in RA patients with severe destroyed joints.

  19. Complications of fluoroscopically directed facet joint nerve blocks: a prospective evaluation of 7,500 episodes with 43,000 nerve blocks.

    PubMed

    Manchikanti, Laxmaiah; Malla, Yogesh; Wargo, Bradley W; Cash, Kimberly A; Pampati, Vidyasagar; Fellows, Bert

    2012-01-01

    Chronic spinal pain is common along with numerous modalities of diagnostic and therapeutic interventions utilized, creating a health care crisis. Facet joint injections and epidural injections are the 2 most commonly utilized interventions in managing chronic spinal pain. While the literature addressing the effectiveness of facet joint nerve blocks is variable and emerging, there is paucity of literature on adverse effects of facet joint nerve blocks. A prospective, non-randomized study of patients undergoing interventional techniques from May 2008 to December 2009. A private interventional pain management practice, a specialty referral center in the United States. Investigation of the incidence in characteristics of adverse effects and complications of facet joint nerve blocks. The study was carried out over a period of 20 months including almost 7,500 episodes of 43,000 facet joint nerve blocks with 3,370 episodes in the cervical region, 3,162 in the lumbar region, and 950 in the thoracic region. All facet joint nerve blocks were performed under fluoroscopic guidance in an ambulatory surgery center by 3 physicians. The complications encountered during the procedure and postoperatively were evaluated prospectively. This study was carried out over a period of 20 months and included over 7,500 episodes or 43,000 facet joint nerve blocks. All of the interventions were performed under fluoroscopic guidance in an ambulatory surgery center by one of 3 physicians. The complications encountered during the procedure and postoperatively were prospectively evaluated. Measurable outcomes employed were intravascular entry of the needle, profuse bleeding, local hematoma, dural puncture and headache, nerve root or spinal cord irritation with resultant injury, and infectious complications. There were no major complications. Multiple side effects and complications observed included overall intravascular penetration in 11.4% of episodes with 20% in cervical region, 4% in lumbar

  20. Rates of Upper Facet Joint Violation in Minimally Invasive Percutaneous and Open Instrumentation: A Comparative Cohort Study of Different Insertion Techniques.

    PubMed

    Archavlis, Eleftherios; Amr, Nimer; Kantelhardt, Sven Rainer; Giese, Alf

    2018-01-01

     Minimally invasive pedicle screw placement may have a higher incidence of violation of the superior cephalad unfused facet joint.  We investigated the incidence and risk factors of upper facet joint violation in percutaneous robot-assisted instrumentation versus percutaneous fluoroscopy-guided and open transpedicular instrumentation.  A retrospective study including all consecutive patients who underwent lumbar instrumentation, fusion, and decompression for spondylolisthetic stenosis and degenerative disk disease was conducted between January 2012 and January 2016. All operations were performed by the same surgeon; the patients were divided into three groups according to the method of instrumentation. Group 1 involved the robot-assisted instrumentation in 58 patients, group 2 consisted of 64 patients treated with a percutaneous transpedicular instrumentation using fluoroscopic guidance, and 72 patients in group 3 received an open midline approach for pedicle screw insertion.  Superior segment facet joint violation occurred in 2 patients in the robot-assisted group 1 (7%), in 22 of the percutaneous fluoroscopy-guided group 2 (34%), and in 6 cases of the open group (8%). The incidence of facet joint violation was present in 5% (3) of the screws in group 1, 22% (28) of the screws in group 2, and 3% (4) of the screws in group 3.  Meticulous surgical planning of the appropriate entry site (Weinstein's method), trajectory planning, and proper robot-assisted instrumentation of pedicle screws reduced the risk of superior segment facet joint violation. Georg Thieme Verlag KG Stuttgart · New York.

  1. The Interface of Mechanics and Nociception in Joint Pathophysiology: Insights From the Facet and Temporomandibular Joints

    PubMed Central

    Sperry, Megan M.; Ita, Meagan E.; Kartha, Sonia; Zhang, Sijia; Yu, Ya-Hsin; Winkelstein, Beth

    2017-01-01

    Chronic joint pain is a widespread problem that frequently occurs with aging and trauma. Pain occurs most often in synovial joints, the body's load bearing joints. The mechanical and molecular mechanisms contributing to synovial joint pain are reviewed using two examples, the cervical spinal facet joints and the temporomandibular joint (TMJ). Although much work has focused on the macroscale mechanics of joints in health and disease, the combined influence of tissue mechanics, molecular processes, and nociception in joint pain has only recently become a focus. Trauma and repeated loading can induce structural and biochemical changes in joints, altering their microenvironment and modifying the biomechanics of their constitutive tissues, which themselves are innervated. Peripheral pain sensors can become activated in response to changes in the joint microenvironment and relay pain signals to the spinal cord and brain where pain is processed and perceived. In some cases, pain circuitry is permanently changed, which may be a potential mechanism for sustained joint pain. However, it is most likely that alterations in both the joint microenvironment and the central nervous system (CNS) contribute to chronic pain. As such, the challenge of treating joint pain and degeneration is temporally and spatially complicated. This review summarizes anatomy, physiology, and pathophysiology of these joints and the sensory pain relays. Pain pathways are postulated to be sensitized by many factors, including degeneration and biochemical priming, with effects on thresholds for mechanical injury and/or dysfunction. Initiators of joint pain are discussed in the context of clinical challenges including the diagnosis and treatment of pain. PMID:28056123

  2. Osseous associated cervical spondylomyelopathy at the C2-C3 articular facet joint in 11 dogs.

    PubMed

    Cooper, C; Gutierrez-Quintana, R; Penderis, J; Gonçalves, R

    2015-11-21

    In dogs, vertebral canal stenosis at C2-C3 due to articular facet joint degeneration is only sporadically identified. The authors' aims were to review the clinical presentation, MRI characteristics, treatment and outcome of dogs presenting with this condition. Eleven cases were eligible for inclusion. Neurological examination revealed tetraparesis and proprioceptive ataxia in all 4 limbs in 3/11, proprioceptive tetra-ataxia only in 4/11, pelvic limb proprioceptive ataxia in 2/11 and no gait abnormalities in 2/11 dogs. Cervical hyperaesthesia was present in 7/11 dogs. MRI revealed bilateral articular facet joint degeneration in 10/11 cases and unilateral degeneration in one. Surgery was performed in six cases and medical management elected in five. Long-term follow-up information was available for 11 animals. Four of the surgical cases are alive and have no neurological deficits, one was euthanased for an unrelated condition and one lost to follow-up. Of the cases managed medically, three are alive showing no neurological deficits, one is alive still displaying neurological deficits and one euthanased for an unrelated condition whilst still ataxic. This study shows that both medical and surgical management can result in good outcomes in dogs with vertebral canal stenosis resulting from articular facet joint degeneration at the level of C2-C3. British Veterinary Association.

  3. Lumbar Facet Joint Compressive Injury Induces Lasting Changes in Local Structure, Nociceptive Scores, and Inflammatory Mediators in a Novel Rat Model

    PubMed Central

    Henry, James L.; Yashpal, Kiran; Vernon, Howard; Kim, Jaesung; Im, Hee-Jeong

    2012-01-01

    Objective. To develop a novel animal model of persisting lumbar facet joint pain. Methods. Sprague Dawley rats were anaesthetized and the right lumbar (L5/L6) facet joint was exposed and compressed to ~1 mm with modified clamps applied for three minutes; sham-operated and naïve animals were used as control groups. After five days, animals were tested for hind-paw sensitivity using von Frey filaments and axial deep tissue sensitivity by algometer on assigned days up to 28 days. Animals were sacrificed at selected times for histological and biochemical analysis. Results. Histological sections revealed site-specific loss of cartilage in model animals only. Tactile hypersensitivity was observed for the ipsi- and contralateral paws lasting 28 days. The threshold at which deep tissue pressure just elicited vocalization was obtained at three lumbar levels; sensitivity at L1 > L3/4 > L6. Biochemical analyses revealed increases in proinflammatory cytokines, especially TNF-α, IL-1α, and IL-1β. Conclusions. These data suggest that compression of a facet joint induces a novel model of local cartilage loss accompanied by increased sensitivity to mechanical stimuli and by increases in inflammatory mediators. This new model may be useful for studies on mechanisms and treatment of lumbar facet joint pain and osteoarthritis. PMID:22966427

  4. Systematic review of patient history and physical examination to diagnose chronic low back pain originating from the facet joints.

    PubMed

    Maas, E T; Juch, J N S; Ostelo, R W J G; Groeneweg, J G; Kallewaard, J W; Koes, B W; Verhagen, A P; Huygen, F J P M; van Tulder, M W

    2017-03-01

    Patient history and physical examination are frequently used procedures to diagnose chronic low back pain (CLBP) originating from the facet joints, although the diagnostic accuracy is controversial. The aim of this systematic review is to determine the diagnostic accuracy of patient history and/or physical examination to identify CLBP originating from the facet joints using diagnostic blocks as reference standard. We searched MEDLINE, EMBASE, CINAHL, Web of Science and the Cochrane Collaboration database from inception until June 2016. Two review authors independently selected studies for inclusion, extracted data and assessed the risk of bias. We calculated sensitivity and specificity values, with 95% confidence intervals (95% CI). Twelve studies were included, in which 129 combinations of index tests and reference standards were presented. Most of these index tests have only been evaluated in single studies with a high risk of bias. Four studies evaluated the diagnostic accuracy of the Revel's criteria combination. Because of the clinical heterogeneity, results were not pooled. The published sensitivities ranged from 0.11 (95% CI 0.02-0.29) to 1.00 (95% CI 0.75-1.00), and the specificities ranged from 0.66 (95% CI 0.46-0.82) to 0.91 (95% CI 0.83-0.96). Due to clinical heterogeneity, the evidence for the diagnostic accuracy of patient history and/or physical examination to identify facet joint pain is inconclusive. Patient history and physical examination cannot be used to limit the need of a diagnostic block. The validity of the diagnostic facet joint block should be studied, and high quality studies are required to confirm the results of single studies. Patient history and physical examination cannot be used to limit the need of a diagnostic block. The validity of the diagnostic facet joint block should be studied, and high quality studies are required to confirm the results of single studies. © 2016 European Pain Federation - EFIC®.

  5. Morphometric Study of Clavicular Facet of Coracoclavicular Joint in Adult Indian Population

    PubMed Central

    Mahajan, Anita; Vasudeva, Neelam

    2016-01-01

    Introduction Anthropologists have used Coracoclavicular Joint (CCJ), a non-metric anatomical variant in population, as a marker for population migration from prehistoric times to present. Aim The aim of this osteological study was to determine the incidence and morphometry of articular facet of CCJ on conoid tubercle of clavicle in Indian population, as Indian studies are scanty and incomplete. Materials and Methods The study was done on 144 adult human clavicles (76 right and 68 left; 93 males and 51 females) collected from osteology museum in Department of Anatomy, Maulana Azad Medical College, New Delhi, India. The presence of articular facet on the conoid tubercle was determined and Maximum Antero-Posterior (MAPD) and maximum transverse diameter (MTD) was measured by digital vernier calliper. The incidence was compared on the basis of sex, side and with other osteological studies in the world. Statistical analysis was done using the Chi-Square test for nominal categorical data and student’s t-test for normally distributed continuous variables in Microsoft Excel 2007 to assess the relationship between the examined variables. Results Articular facet on conoid tubercle was found in 8 cases (5.6%). Seven (9.2%) were present on the right side and one (1.5%) on the left side. Seven cases (7.5%) were present in males and one case (2%) was found in females. The facets were generally oval, with MAPD and MTD of 12.28 and 17.17 mm respectively. A significant side variation was present with right sided facet being more common. The left sided facet was more transversely elongated than right. In males, the facets were more elongated antero-posteriorly than in females. Conclusion The Indian population showed an incidence of 5.6%, which was comparable to other ethnic groups in world population. The morphometric and side differences could be attributed to the occupational factors and range of movements associated with the CCJ. The CCJ should be borne in mind as a differential

  6. Facet joint injections as a means of reducing the need for vertebroplasty in insufficiency fractures of the spine.

    PubMed

    Wilson, David J; Owen, Sara; Corkill, Rufus A

    2011-08-01

    Recent publications compared treatment of vertebral fractures reporting improvement in the majority but with no significant difference between the local anaesthetic and vertebroplasty groups. Potential explanations include placebo response or therapeutic response to the "control procedure". We investigated whether preliminary facet joint injection can identify those patients whose pain arises from paravertebral structures rather than the vertebral insufficiency fracture itself. Patients referred for treatment by vertebroplasty were first offered local anaesthetic and steroid facet joint injection (FJI) at the most painful level. Those who failed to respond were offered a vertebroplasty. Ninety one patients referred, 16 went straight to vertebroplasty. Sixty one of 75 were initially offered FJI. Twenty one were successful; two relapsed, had further FJIs with good results; three declined treatment; 5 had temporary benefit; 1 died from unrelated causes. Of 29 who failed to respond to FJIs, 24 underwent vertebroplasty and 23 had a successful outcome. A third of patients technically suitable for vertebroplasty responded beneficially to FJI. In this group the pain mediator maybe one of instability and overload on the facet joints produced by adjacent wedge fracture. This protocol allows more selective and more successful vertebroplasty.

  7. [Human joint capsule in osteoarthrosis (morpholocical changes) (author's transl)].

    PubMed

    Dettmer, N; Barz, B

    1977-07-29

    Morphological investigations of the joint capsules in osteoarthrotic-changed joints have given rise to doubts about the present theory of the causal aetiology of the osteoarthrosis. In every inspected and demonstrated illustration beside the partly normal capsules segments could be found every transition between mild regressive alterations and most massive proliferative changes of the conective tissue and the lining cell layer. It was extraordinary, that the strongly dilated vessels were filled with red blood cells. In another part of the same case was found a massive stricture caused by concentrically deposited substances, which were impregnated with collagenous fibers. Regeneration of the vessels frequently happened adjacent totally obstructed ones. Round-cell infiltrations, granulocytes or other indications of an inflammatory synovitis are found only in a few cases. The intracartilaginous enzymatic reactions, which have been much talked of and which were explained as characteristic of the osteoarthrosis cannot be the cause of the degradation of the cartilage, particularly, because of the normal cell count which is to be found in the synovial fluid. We can answer this problem, if we can prove that the substrates of the chondral metabolism themselves exert a direct or indirect influence on the interstitial connective tissue with induction of the powerful proliferation of the same tissue. The changes in the transit zone would be secondary and their effect on the lining cell layer would increase the progression of the arthrotic events.

  8. FacetGist: Collective Extraction of Document Facets in Large Technical Corpora

    PubMed Central

    Siddiqui, Tarique; Ren, Xiang; Parameswaran, Aditya; Han, Jiawei

    2017-01-01

    Given the large volume of technical documents available, it is crucial to automatically organize and categorize these documents to be able to understand and extract value from them. Towards this end, we introduce a new research problem called Facet Extraction. Given a collection of technical documents, the goal of Facet Extraction is to automatically label each document with a set of concepts for the key facets (e.g., application, technique, evaluation metrics, and dataset) that people may be interested in. Facet Extraction has numerous applications, including document summarization, literature search, patent search and business intelligence. The major challenge in performing Facet Extraction arises from multiple sources: concept extraction, concept to facet matching, and facet disambiguation. To tackle these challenges, we develop FacetGist, a framework for facet extraction. Facet Extraction involves constructing a graph-based heterogeneous network to capture information available across multiple local sentence-level features, as well as global context features. We then formulate a joint optimization problem, and propose an efficient algorithm for graph-based label propagation to estimate the facet of each concept mention. Experimental results on technical corpora from two domains demonstrate that Facet Extraction can lead to an improvement of over 25% in both precision and recall over competing schemes. PMID:28210517

  9. FacetGist: Collective Extraction of Document Facets in Large Technical Corpora.

    PubMed

    Siddiqui, Tarique; Ren, Xiang; Parameswaran, Aditya; Han, Jiawei

    2016-10-01

    Given the large volume of technical documents available, it is crucial to automatically organize and categorize these documents to be able to understand and extract value from them. Towards this end, we introduce a new research problem called Facet Extraction. Given a collection of technical documents, the goal of Facet Extraction is to automatically label each document with a set of concepts for the key facets ( e.g. , application, technique, evaluation metrics, and dataset) that people may be interested in. Facet Extraction has numerous applications, including document summarization, literature search, patent search and business intelligence. The major challenge in performing Facet Extraction arises from multiple sources: concept extraction, concept to facet matching, and facet disambiguation. To tackle these challenges, we develop FacetGist, a framework for facet extraction. Facet Extraction involves constructing a graph-based heterogeneous network to capture information available across multiple local sentence-level features, as well as global context features. We then formulate a joint optimization problem, and propose an efficient algorithm for graph-based label propagation to estimate the facet of each concept mention. Experimental results on technical corpora from two domains demonstrate that Facet Extraction can lead to an improvement of over 25% in both precision and recall over competing schemes.

  10. Ketorolac reduces spinal astrocytic activation and PAR1 expression associated with attenuation of pain after facet joint injury.

    PubMed

    Dong, Ling; Smith, Jenell R; Winkelstein, Beth A

    2013-05-15

    Chronic neck pain affects up to 70% of persons, with the facet joint being the most common source. Intra-articular injection of the non-steroidal anti-inflammatory drug ketorolac reduces post-operative joint-mediated pain; however, the mechanism of its attenuation of facet-mediated pain has not been evaluated. Protease-activated receptor-1 (PAR1) has differential roles in pain maintenance depending on the type and location of painful injury. This study investigated if the timing of intra-articular ketorolac injection after painful cervical facet injury affects behavioral hypersensitivity by modulating spinal astrocyte activation and/or PAR1 expression. Rats underwent a painful joint distraction and received an injection of ketorolac either immediately or 1 day later. Separate control groups included injured rats with a vehicle injection at day 1 and sham operated rats. Forepaw mechanical allodynia was measured for 7 days, and spinal cord tissue was immunolabeled for glial fibrillary acidic protein (GFAP) and PAR1 expression in the dorsal horn on day 7. Ketorolac administered on day 1 after injury significantly reduced allodynia (p=0.0006) to sham levels, whereas injection immediately after the injury had no effect compared with vehicle. Spinal astrocytic activation followed behavioral responses and was significantly decreased (p=0.009) only for ketorolac given at day 1. Spinal PAR1 (p=0.0025) and astrocytic PAR1 (p=0.012) were significantly increased after injury. Paralleling behavioral data, astrocytic PAR1 was returned to levels in sham only when ketorolac was administered on day 1. Yet, spinal PAR1 was significantly reduced (p<0.0001) by ketorolac independent of timing. Spinal astrocyte expression of PAR1 appears to be associated with the maintenance of facet-mediated pain.

  11. Ketorolac Reduces Spinal Astrocytic Activation and PAR1 Expression Associated with Attenuation of Pain after Facet Joint Injury

    PubMed Central

    Dong, Ling; Smith, Jenell R.

    2013-01-01

    Abstract Chronic neck pain affects up to 70% of persons, with the facet joint being the most common source. Intra-articular injection of the non-steroidal anti-inflammatory drug ketorolac reduces post-operative joint-mediated pain; however, the mechanism of its attenuation of facet-mediated pain has not been evaluated. Protease-activated receptor-1 (PAR1) has differential roles in pain maintenance depending on the type and location of painful injury. This study investigated if the timing of intra-articular ketorolac injection after painful cervical facet injury affects behavioral hypersensitivity by modulating spinal astrocyte activation and/or PAR1 expression. Rats underwent a painful joint distraction and received an injection of ketorolac either immediately or 1 day later. Separate control groups included injured rats with a vehicle injection at day 1 and sham operated rats. Forepaw mechanical allodynia was measured for 7 days, and spinal cord tissue was immunolabeled for glial fibrillary acidic protein (GFAP) and PAR1 expression in the dorsal horn on day 7. Ketorolac administered on day 1 after injury significantly reduced allodynia (p=0.0006) to sham levels, whereas injection immediately after the injury had no effect compared with vehicle. Spinal astrocytic activation followed behavioral responses and was significantly decreased (p=0.009) only for ketorolac given at day 1. Spinal PAR1 (p=0.0025) and astrocytic PAR1 (p=0.012) were significantly increased after injury. Paralleling behavioral data, astrocytic PAR1 was returned to levels in sham only when ketorolac was administered on day 1. Yet, spinal PAR1 was significantly reduced (p<0.0001) by ketorolac independent of timing. Spinal astrocyte expression of PAR1 appears to be associated with the maintenance of facet-mediated pain. PMID:23126437

  12. A Novel Technique for Cervical Facet Joint Hyperplasia-Spondylotic Radiculopathy by Laminar and Lateral Mass Screw Cofixations.

    PubMed

    Sheng, Sun-Ren; Wang, Ke; Nisar, Majid; Chen, Jiao-Xiang; Wu, Ai-Min; Wang, Xiang-Yang

    2018-02-01

    We sought to describe the novel technique and report the outcomes of cervical spondylotic radiculopathy caused by facet joint hyperplasia treated with minimally invasive surgery by laminar and lateral mass screw cofixations. In this retrospective study, patients with spondylotic radiculopathy caused by facet joint hyperplasia underwent this technique in our unit between January 2010 and June 2015. Hospital charts, magnetic resonance imaging studies, and follow-up records for all the patients were reviewed. Outcomes were assessed on the basis of neurologic status, magnetic resonance imaging, and visual analog scale for neck and radicular pain and by the short form-36 health survey questionnaire. Thirteen men and 5 women, aged 47-73 years (mean, 61.8 years), were included in this study. The follow-up time ranged from 19-50 months (mean, 32.4 months). The mean visual analog scale scores for radicular pain and neck pain, as well as the scores for all 8 domains of the short form-36 health survey questionnaire, showed significant improvements (P < 0.05). Cervical lordosis showed bending, whereas the height of the targeted disk segment showed no change (P > 0.05). Complications included 2 cases of neck pain that lasted for 3 months. Minimally invasive surgery by lamina and lateral mass screw cofixation is safe and effective for the treatment of cervical spondylotic radiculopathy caused by facet joint hyperplasia. In addition to sufficient decompression, this technique provides relative stability to the cervical spine. Copyright © 2017 The Author(s). Published by Elsevier Inc. All rights reserved.

  13. Melorheostosis of the tenth and eleventh thoracic vertebrae crossing the facet joint: a rare cause of back pain.

    PubMed

    McCarthy, M; Mehdian, H; Fairbairn, K J; Stevens, A

    2004-05-01

    Melorheostosis affecting the axial skeleton is a rare condition. We present a case affecting a single thoracic zygoapophyseal (facet) joint that proved to be a diagnostic challenge. CT, MRI and radionuclide imaging with surgical and histopathology findings are discussed.

  14. Fluoroscopically guided infiltration of the cervical nerve root: an indirect approach through the ipsilateral facet joint.

    PubMed

    Kelekis, Alexios; Filippiadis, Dimitrios K; Velonakis, Georgios; Martin, Jean-Baptist; Oikonomopoulos, Nikolaos; Brountzos, Elias; Kelekis, Nikolaos

    2014-01-01

    Transforaminal infiltrations in the cervical spine are governed by a higher rate of vascular puncture than in the lumbar spine. The purpose of our study is to assess the safety and efficacy of percutaneous, fluoroscopically guided nerve root infiltrations in cases of cervical radiculopathy. An indirect postero-lateral approach was performed through the ipsilateral facet joint. During the last 2 years, 25 patients experiencing cervical radiculopathy underwent percutaneous, fluoroscopically guided nerve root infiltrations by means of an indirect postero-lateral approach through the ipsilateral facet joint. The intra-articular position of the needle (22-gauge spinal needle) was fluoroscopically verified after injection of a small amount of contrast medium which also verified dispersion of the contrast medium periradicularly and in the epidural space. Then a mixture of long-acting glucocorticosteroid diluted in normal saline (1.5/1 mL) was injected intra-articularly. A questionnaire with a Numeric Visual Scale (NVS) scale helped assess pain relief, life quality, and mobility improvement. A mean of 2.3 sessions was performed in the patients of our study. In the vast majority of our patients 19/25 (76%), the second infiltration was performed within 7-10 days of the first one. Comparing the pain scores prior (mean value 8.80 ± 1.080 NVS units) and after (mean value 1.84 ± 1.405 NVS units), there was a mean decrease of 6.96 ± 1.695 NVS units [median value 7 NVS units (P < 0.001) in terms of pain reduction, effect upon mobility, and life quality. There were no clinically significant complications noted in our study. Fluoroscopically guided transforaminal infiltrations through the ipsilateral facet joint seem to be a feasible, efficacious, and safe approach for the treatment of patients with cervical radiculopathy. This approach facilitates needle placement and minimizes risk of complications.

  15. Poly(ethylene glycol)/chitosan/sodium glycerophosphate gel replaced the joint capsule with slow-release lubricant after joint surgery.

    PubMed

    Lu, Hailin; Ren, Shanshan; Li, Xing; Guo, Junde; Dong, Guangneng; Li, Jianhui; Gao, Li

    2018-08-01

    Body fluid is normally the only lubricant after joint replacement surgery, but wear problems have occurred because body fluid has poor lubrication ability. However, traditional lubricant would be diluted by body fluids and then absorbed by the human body. Therefore, an injectable gel with the ability to slow-release lubricant was designed to replace the joint capsule. The proposed gel, poly(ethylene glycol)/chitosan/sodium glycerophosphate (PEG/CS/GP) composite gel was then tested. The tribology results showed that the PEG/CS/GP gel had excellent slow-release properties, especially under pressure, and the PEG played an important role in improving the gel's rheological and mechanical properties. Moreover, this study revealed that the release solution had a good lubrication effect because the PEG and GP could crosslink via the hydrogen bond effect.

  16. Efficacy of lateral- versus medial-approach hip joint capsule denervation as surgical treatments of the hip joint pain; a neuronal tract tracing study in the sheep

    PubMed Central

    Sienkiewicz, Waldemar; Dudek, Agnieszka; Czaja, Krzysztof; Janeczek, Maciej; Chrószcz, Aleksander; Kaleczyc, Jerzy

    2018-01-01

    Objective To evaluate efficacy of denervation of the of the hip joint capsule (HJC), as a treatment of hip joint pain. Specifically, we tested the hypothesis that HJC denervation will significantly reduce the number of sensory neurons innervating the capsule. Study design Denervation of the HJC from a medial or lateral approach was followed by retrograde tracing of sensory neurons innervating the capsule. Animals Twenty adult male sheep (30–40 kg of body weight; Polish merino breed) were used in the study. Methods The hip joint was denervated from medial (n = 5) or lateral (n = 5) surgical approaches. Immediately after denervation, the retrograde neural tract tracer Fast Blue (FB) was injected into the HJC. An additional ten animals (n = 5 for medial and n = 5 for lateral approach) received the same treatment without HJC denervation to provide the appropriate controls. Results Results of the study revealed that the vast majority of retrogradely labelled sensory neurons innervating the HJC originate from fifth lumbar to second sacral dorsal root ganglia. Both the medial and the lateral denervations significantly reduced the number of sensory neurons innervating the HJC (39.2% and 69.0% reduction respectively). Conclusions These results show that denervation of the HJC is an effective surgical procedure for reduction of the sensory neuronal input to the HJC. Moreover, the lateral approach was found to be significantly more effective for reducing sensory innervation as compared to the medial one. PMID:29329303

  17. Reduction of radiation dose during facet joint injection using the new image guidance system SabreSource™: a prospective study in 60 patients

    PubMed Central

    Proschek, Dirk; Kafchitsas, K.; Rauschmann, M. A.; Kurth, A. A.; Vogl, T. J.

    2008-01-01

    Interventional procedures are associated with high radiation doses for both patients and surgeons. To reduce the risk from ionizing radiation, it is essential to minimize radiation dose. This prospective study was performed to evaluate the effectiveness in reducing radiation dose during facet joint injection in the lumbar spine and to evaluate the feasibility and possibilities of the new real time image guidance system SabreSource™. A total of 60 patients, treated with a standardized injection therapy of the facet joints L4–L5 or L5–S1, were included in this study. A total of 30 patients were treated by fluoroscopy guidance alone, the following 30 patients were treated using the new SabreSource™ system. Thus a total of 120 injections to the facet joints were performed. Pain, according to the visual analogue scale (VAS), was documented before and 6 h after the intervention. Radiation dose, time of radiation and the number of exposures needed to place the needle were recorded. No significant differences concerning age (mean age 60.5 years, range 51–69), body mass index (mean BMI 26.2, range 22.2–29.9) and preoperative pain (VAS 7.9, range 6–10) were found between the two groups. There was no difference in pain reduction between the two groups (60 vs. 61.5%; P = 0.001) but the radiation dose was significantly smaller with the new SabreSource™ system (reduction of radiation dose 32.7%, P = 0.01; reduction of mean entrance surface dose 32.3%, P = 0.01). The SabreSource™ System significantly reduced the radiation dose received during the injection therapy of the lumbar facet joints. With minimal effort for the setup at the beginning of a session, the system is easy to handle and can be helpful for other injection therapies (e.g. nerve root block therapies). PMID:19082641

  18. Joint capsule attachment to the extensor carpi radialis brevis origin: an anatomical study with possible implications regarding the etiology of lateral epicondylitis.

    PubMed

    Nimura, Akimoto; Fujishiro, Hitomi; Wakabayashi, Yoshiaki; Imatani, Junya; Sugaya, Hiroyuki; Akita, Keiichi

    2014-02-01

    To identify the unique anatomical characteristic of the extensor carpi radialis brevis (ECRB) origin and points of differentiation from other extensors and to clarify the specific relationship of the ECRB to the underlying structures. We studied the origin of each extensor macroscopically for its muscular and tendinous parts; to identify the relationship between the ECRB origin and the deeper structures, we also examined the attachment of the joint capsule under the ECRB origin. The ECRB simply originated as a tendon without any muscle, whereas other extensors originated as a mixture of tendon and muscle. At the anterior part of the ECRB origin, the thin attachment of the joint capsule (average width, 3.3 mm) lay deep to the ECRB and was distinct. However, at the posterodistal portion, the joint capsule, annular ligament, and supinator were intermingled and originated as a single wide sheet from the humerus (average width, 10.7 mm). The anterior part of the ECRB origin was delicate, because the ECRB origin was purely tendinous, and the attachment of the articular capsule was thin compared with that of the posterodistal attachment. This thin attachment could be an initial factor leading to the development of lateral epicondylitis. The results of the current study may enhance magnetic resonance imaging understanding and may help clarify the etiology of the lateral epicondylitis. Copyright © 2014 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  19. An International Multicenter Study Assessing the Role of Ethnicity on Variation of Lumbar Facet Joint Orientation and the Occurrence of Degenerative Spondylolisthesis in Asia Pacific: A Study from the AOSpine Asia Pacific Research Collaboration Consortium

    PubMed Central

    Williams, Richard; Cheung, Jason Pui Yin; Goss, Ben; Rajasekaran, Shanmuganathan; Kawaguchi, Yoshiharu; Acharya, Shankar; Kawakami, Mamoru; Satoh, Shigenobu; Chen, Wen-Jer; Park, Chun-Kun; Lee, Chong-Suh; Foocharoen, Thanit; Nagashima, Hideki; Kuh, Sunguk; Zheng, Zhaomin; Condor, Richard; Ito, Manabu; Iwasaki, Motoki; Jeong, Je Hoon; Luk, Keith D. K.; Prijambodo, Bambang; Rege, Amol; Jahng, Tae-Ahn; Luo, Zhuojing; Tassanawipas, Warat; Acharya, Narayana; Pokharel, Rohit; Shen, Yong; Ito, Takui; Zhang, Zhihai; Aithala P, Janardhana; Kumar, Gomatam Vijay; Jabir, Rahyussalim Ahmad; Basu, Saumyajit; Li, Baojun; Moudgil, Vishal; Sham, Phoebe; Samartzis, Dino

    2015-01-01

    Study Design A multinational, multiethnic, cross-sectional image-based study was performed in 33 institutions, representing 10 countries, which were part of the AOSpine Asia Pacific Research Collaboration Consortium. Objective Lumbar facet joint orientation has been reported to be associated with the development of degenerative spondylolisthesis (DS). The role of ethnicity regarding facet joint orientation remains uncertain. As such, the following study was performed across a wide-ranging population base to assess the role of ethnicity in facet joint orientation in patients with DS in the Asia Pacific region. Methods Lateral standing X-rays and axial magnetic resonance imaging scans were obtained for patients with lumbar DS. The DS parameters and facet joint angulations were assessed from L3–S1. Sex, age, body mass index (BMI), and ethnicity were also noted. Results The study included 371 patients with known ethnic origin (mean age: 62.0 years; 64% males, 36% females). The mean BMI was 25.6 kg/m2. The level of DS was most prevalent at L4–L5 (74.7%). There were 28.8% Indian, 28.6% Japanese, 18.1% Chinese, 8.6% Korean, 6.5% Thai, 4.9% Caucasian, 2.7% Filipino, and 1.9% Malay patients. Variations in facet joint angulations were noted from L3 to S1 and between patients with and without DS (p < 0.05). No differences were noted with regards to sex and overall BMI to facet joint angulations (p > 0.05); however, increasing age was found to increase the degree of angulation throughout the lumbar spine (p < 0.05). Accounting for age and the presence or absence of DS at each level, no statistically significant differences between ethnicity and degree of facet joint angulations from L3–L5 were noted (p > 0.05). Ethnic variations were noted in non-DS L5–S1 facet joint angulations, predominantly between Caucasian, Chinese, and Indian ethnicities (p < 0.05). Conclusions This study is the first to suggest that ethnicity may not play a role in

  20. The lumbar facet arthrosis syndrome. Clinical presentation and articular surface changes.

    PubMed

    Eisenstein, S M; Parry, C R

    1987-01-01

    We describe a lumbar facet syndrome in which disabling symptoms are associated with normal or near-normal plain radiographs. Local spinal fusion relieved symptoms in 12 patients; the excised facet joint surfaces showed some of the histological changes seen in chondromalacia patellae and in osteoarthritis of other large joints. The most frequent change was focal full-thickness cartilage necrosis or loss of cartilage with exposure of subchondral bone, but osteophyte formation was remarkably absent in all specimens. We suggest that there are both clinical and histological similarities between the facet arthrosis syndrome and chondromalacia patellae. Facet arthrosis may be a relatively important cause of intractable back pain in young and middle-aged adults.

  1. Morphological Asymmetry of the Superior Cervical Facets from C3 through C7 due to Degeneration.

    PubMed

    Van Vlasselaer, Nicolas; Van Roy, Peter; Cattrysse, Erik

    2017-01-01

    Knowledge about facet morphology has already been discussed extensively in literature but is limited regarding asymmetry and its relation to facet degeneration. Facet dimensions, surface area, curvature, and degeneration of the superior facets were measured in 85 dried human vertebrae from the anatomical collection of the Vrije Universiteit Brussel. The vertebrae were analysed using the Microscribe G2X digitizer (Immersion Co., San Jose, CA) and a grading system for the evaluation of cervical facet degeneration. Coordinates were processed mathematically to evaluate articular tropism. The statistical analysis includes the paired t -test and the Pearson correlation. On average, no systematic differences between the left and right facets were found concerning morphology and degeneration. However, there were significant differences regardless of the side-occurrence. There was a significant correlation between the dimensions of the total facet surface and the degree of degeneration but not for the recognizable joint surface. Facet tropism of the upper joint facets occurred often in the cervical spine but without side preference. A bigger difference in degeneration asymmetry was associated with a bigger difference in facet joint dimension asymmetry.

  2. Distraction of facets with intraarticular spacers as treatment for lumbar canal stenosis: report on a preliminary experience with 21 cases.

    PubMed

    Goel, Atul; Shah, Abhidha; Jadhav, Madan; Nama, Santhosh

    2013-12-01

    The authors report their experience in treating 21 patients by using a novel form of treatment of lumbar degenerative disease that leads to canal stenosis. The surgery involved distraction of the facets using specially designed Goel intraarticular spacers and was aimed at arthrodesis of the spinal segment in a distracted position. The operation is based on the premise that subtle and longstanding facet instability, joint space reduction, and subsequent facet override had a profound and primary influence in the pathogenesis of degenerative lumbar canal stenosis. The surgical technique and the rationale for treatment are discussed. Between April 2006 and January 2011, 21 cases of lumbar degenerative disease resulting in characteristic lumbar canal stenosis were treated in the authors' department with the proposed technique. The patients were prospectively analyzed. There were 15 men and 6 women who ranged in age from 48 to 71 years (mean 58 years). Nine patients underwent 1-level and 12 patients underwent 2-level treatment. Surgery involved wide opening of the articular joint, denuding of the articular capsule/endplate cartilage, distraction of the facets, and forced impaction of Goel intraarticular spacers. Bone graft pieces obtained by sectioning the spinous processes were placed within and over the joint and in the midline over the adequately prepared host area of laminae. The Oswestry Disability Index and visual analog scale were used to clinically assess the patients before and after surgery and at follow-up. The alterations in the physical architecture of spinal canal and intervertebral foramen dimensions were evaluated before and after placement of the intrafacet implant and after at least 6 months of follow-up. All patients had varying degrees of relief from symptoms of local back pain and radiculopathy. Impaction of spacers within the facet joints resulted in an increase in the spinal canal and intervertebral root canal dimensions (mean 2.33 mm), reduction

  3. The efficacy of conventional radiofrequency denervation in patients with chronic low back pain originating from the facet joints: a meta-analysis of randomized controlled trials.

    PubMed

    Lee, Chang-Hyun; Chung, Chun Kee; Kim, Chi Heon

    2017-11-01

    Radiofrequency denervation is commonly used for the treatment of chronic facet joint pain that has been refractory to more conservative treatments, although the evidence supporting this treatment has been controversial. We aimed to elucidate the precise effects of radiofrequency denervation in patients with low back pain originating from the facet joints relative to those obtained using control treatments, with particular attention to consistency in the denervation protocol. A meta-analysis of randomized controlled trials was carried out. Adult patients undergoing radiofrequency denervation or control treatments (sham or epidural block) for facet joint disease of the lumbar spine comprised the patient sample. Visual analog scale (VAS) pain scores were measured and stratified by response of diagnostic block procedures. We searched PubMed, Embase, Web of Science, and the Cochrane Database for randomized controlled trials regarding radiofrequency denervation and control treatments for back pain. Changes in VAS pain scores of the radiofrequency group were compared with those of the control group as well as the minimal clinically important difference (MCID) for back pain VAS. Meta-regression model was developed to evaluate the effect of radiofrequency treatment according to responses of diagnostic block while controlling for other variables. We then calculated mean differences and 95% confidence intervals (CIs) using random-effects models. We included data from seven trials involving 454 patients who had undergone radiofrequency denervation (231 patients) and control treatments such as sham or epidural block procedures (223 patients). The radiofrequency group exhibited significantly greater improvements in back pain score when compared with the control group for 1-year follow-up. Although the average improvement in VAS scores exceeded the MCID, the lower limit of the 95% CI encompassed the MCID. A subgroup of patients who responded very well to diagnostic block

  4. Morphological Asymmetry of the Superior Cervical Facets from C3 through C7 due to Degeneration

    PubMed Central

    Van Roy, Peter

    2017-01-01

    Introduction Knowledge about facet morphology has already been discussed extensively in literature but is limited regarding asymmetry and its relation to facet degeneration. Method Facet dimensions, surface area, curvature, and degeneration of the superior facets were measured in 85 dried human vertebrae from the anatomical collection of the Vrije Universiteit Brussel. The vertebrae were analysed using the Microscribe G2X digitizer (Immersion Co., San Jose, CA) and a grading system for the evaluation of cervical facet degeneration. Coordinates were processed mathematically to evaluate articular tropism. The statistical analysis includes the paired t-test and the Pearson correlation. Results On average, no systematic differences between the left and right facets were found concerning morphology and degeneration. However, there were significant differences regardless of the side-occurrence. There was a significant correlation between the dimensions of the total facet surface and the degree of degeneration but not for the recognizable joint surface. Conclusions Facet tropism of the upper joint facets occurred often in the cervical spine but without side preference. A bigger difference in degeneration asymmetry was associated with a bigger difference in facet joint dimension asymmetry. PMID:29359153

  5. The mechanism of joint capsule thermal modification in an in-vitro sheep model.

    PubMed

    Hayashi, K; Peters, D M; Thabit, G; Hecht, P; Vanderby, R; Fanton, G S; Markel, M D

    2000-01-01

    The purpose of this study was to understand the mechanism responsible for joint capsule shrinkage after nonablative laser application in an in-vitro sheep model. Femoropatellar joint capsular tissue specimens harvested from 20 adult sheep were treated with one of three power settings of a holmium:yttrium-aluminum-garnet laser or served as a control. Laser treatment significantly shortened the tissue and decreased tissue stiffness in all three laser groups, whereas failure strength was not altered significantly by laser treatment. Transmission electron microscopic examination showed swollen collagen fibrils and loss of membrane integrity of fibroblasts. A thermometric study revealed nonablative laser energy caused tissue temperature to rise in the range of 64 degrees C to 100 degrees C. Electrophoresis after trypsin digestion of the tissue revealed significant loss of distinct alpha bands of Type I collagen in laser treated samples, whereas alpha bands were present in laser treated tissue without trypsin digestion. The results of this study support the concept that the primary mechanism responsible for the effect of nonablative laser energy is thermal denaturation of collagen in joint capsular tissue associated with unwinding of the triple helical structure of the collagen molecule.

  6. Randomised sham-controlled double-blind multicentre clinical trial to ascertain the effect of percutaneous radiofrequency treatment for lumbar facet joint pain.

    PubMed

    van Tilburg, C W J; Stronks, D L; Groeneweg, J G; Huygen, F J P M

    2016-11-01

    The aim of this study was to compare the effect of a percutaneous radiofrequency heat lesion at the medial branch of the primary dorsal ramus with a sham procedure, for the treatment of lumbar facet joint pain. A randomised sham-controlled double blind multicentre trial was carried out at the multidisciplinary pain centres of two hospitals. A total of 60 patients aged > 18 years with a history and physical examination suggestive of facet joint pain and a decrease of ≥ 2 on a numerical rating scale (NRS 0 to 10) after a diagnostic facet joint test block were included. In the treatment group, a percutaneous radiofrequency heat lesion (80 o C during 60 seconds per level) was applied to the medial branch of the primary dorsal ramus. In the sham group, the same procedure was undertaken without for the radiofrequency lesion. Both groups also received a graded activity physiotherapy programme. The primary outcome measure was decrease in pain. A secondary outcome measure was the Global Perceived Effect scale (GPE). There was a statistically significant effect on the level of pain in the factor Period (T0-T1). However, there was no statistically significant difference with the passage of time between the groups (Group × Period) or in the factor Group. In the crossover group, 11 of 19 patients had a decrease in NRS of ≥ 2 at one month crossover (p = 0.65). There was no statistically significant difference in satisfaction with the passage of time between the groups (Group × Period). The independent factors Group and Period also showed no statistically significant difference. There was no statistically significant Group × Period effect for recovery, neither an effect of Group or of Period. The null hypothesis of no difference in the decrease in pain and in GPE between the treatment and sham groups cannot be rejected. Post hoc analysis revealed that the age of the patients and the severity of the initial pain significantly predicted a positive outcome. Cite this article

  7. Quantitative morphometric analysis of the lumbar vertebral facets and evaluation of feasibility of lumbar spinal nerve root and spinal canal decompression using the Goel intraarticular facetal spacer distraction technique: A lumbar/cervical facet comparison

    PubMed Central

    Satoskar, Savni R.; Goel, Aimee A.; Mehta, Pooja H.; Goel, Atul

    2014-01-01

    Objective: The authors evaluate the anatomic subtleties of lumbar facets and assess the feasibility and effectiveness of use of ‘Goel facet spacer’ in the treatment of degenerative spinal canal stenosis. Materials and Methods: Twenty-five lumbar vertebral cadaveric dried bones were used for the purpose. A number of morphometric parameters were evaluated both before and after the introduction of Goel facet spacers within the confines of the facet joint. Results: The spacers achieved distraction of facets that was more pronounced in the vertical perspective. Introduction of spacers on both sides resulted in an increase in the intervertebral foraminal height and a circumferential increase in the spinal canal dimensions. Additionally, there was an increase in the disc space or intervertebral body height. The lumbar facets are more vertically and anteroposteriorly oriented when compared to cervical facets that are obliquely and transversely oriented. Conclusions: Understanding the anatomical peculiarities of the lumbar and cervical facets can lead to an optimum utilization of the potential of Goel facet distraction arthrodesis technique in the treatment of spinal degenerative canal stenosis. PMID:25558146

  8. [Study on the effect of vertebrae semi-dislocation on the stress distribution in facet joint and interuertebral disc of patients with cervical syndrome based on the three dimensional finite element model].

    PubMed

    Zhang, Ming-cai; Lü, Si-zhe; Cheng, Ying-wu; Gu, Li-xu; Zhan, Hong-sheng; Shi, Yin-yu; Wang, Xiang; Huang, Shi-rong

    2011-02-01

    To study the effect of vertebrae semi-dislocation on the stress distribution in facet joint and interuertebral disc of patients with cervical syndrome using three dimensional finite element model. A patient with cervical spondylosis was randomly chosen, who was male, 28 years old, and diagnosed as cervical vertebra semidislocation by dynamic and static palpation and X-ray, and scanned from C(1) to C(7) by 0.75 mm slice thickness of CT. Based on the CT data, the software was used to construct the three dimensional finite element model of cervical vertebra semidislocation (C(4)-C(6)). Based on the model,virtual manipulation was used to correct the vertebra semidislocation by the software, and the stress distribution was analyzed. The result of finite element analysis showed that the stress distribution of C(5-6) facet joint and intervertebral disc changed after virtual manipulation. The vertebra semidislocation leads to the abnormal stress distribution of facet joint and intervertebral disc.

  9. Role of facet curvature for accurate vertebral facet load analysis.

    PubMed

    Holzapfel, Gerhard A; Stadler, Michael

    2006-06-01

    The curvature of vertebral facet joints may play an important role in the study of load-bearing characteristics and clinical interventions such as graded facetectomy. In previously-published finite element simulations of this procedure, the curvature was either neglected or approximated with a varying degree of accuracy. Here we study the effect of the curvature in three different load situations by using a numerical model which is able to represent the actual curvature without any loss of accuracy. The results show that previously-used approximations of the curvature lead to good results in the analysis of sagittal moment/rotation. However, for sagittal shear-force/displacement and for the contact stress distribution, previous results deviate significantly from our results. These findings are supported through related convergence studies. Hence we can conclude that in order to obtain reliable results for the analysis of sagittal shear-force/displacement and the contact stress distribution in the facet joint, the curvature must not be neglected. This is of particular importance for the numerical simulation of the spine, which may lead to improved diagnostics, effective surgical planning and intervention. The proposed method may represent a more reliable basis for optimizing the biomedical engineering design for tissue engineering or, for example, for spinal implants.

  10. Biomechanics of the L5-S1 motion segment after total disc replacement - Influence of iatrogenic distraction, implant positioning and preoperative disc height on the range of motion and loading of facet joints.

    PubMed

    Dreischarf, Marcel; Schmidt, Hendrik; Putzier, Michael; Zander, Thomas

    2015-09-18

    Total disc replacement has been introduced to overcome negative side effects of spinal fusion. The amount of iatrogenic distraction, preoperative disc height and implant positioning have been considered important for surgical success. However, their effect on the postoperative range of motion (RoM) and loading of the facets merits further discussion. A validated osteoligamentous finite element model of the lumbosacral spine was employed and extended with four additional models to account for different disc heights. An artificial disc with a fixed center of rotation (CoR) was implemented in L5-S1. In 4000 simulations, the influence of distraction and the CoR's location on the RoM, facet joint forces (FJFs) and facet capsule ligament forces (FCLFs) was investigated. Distraction substantially altered segmental kinematics in the sagittal plane by decreasing range of flexion (0.5° per 1mm of distraction), increasing range of extension (0.7°/mm) and slightly affecting complete sagittal RoM (0.2°/mm). The distraction already strongly increased the FCLFs during surgery (up to 230N) and in flexion (~12N/mm), with higher values in models with larger preoperative disc heights, and increased FJFs in extension. A more anterior implant location decreased the RoM in all planes. In most loading cases, a more posterior location of the implant's CoR increased the FJFs and FCLFs, whereas a more caudal location increased the FCLFs but decreased the FJFs. The results of this study may explain the worse clinical results in patients with overdistraction after TDR. The complete RoM in the sagittal plane appears to be insensitive to detecting surgery-related biomechanical changes. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Pain from intra-articular NGF or joint injury in the rat requires contributions from peptidergic joint afferents.

    PubMed

    Kras, Jeffrey V; Weisshaar, Christine L; Pall, Parul S; Winkelstein, Beth A

    2015-09-14

    Non-physiological stretch of the cervical facet joint's capsular ligament induces persistent behavioral hypersensitivity and spinal neuronal hyperexcitability via an intra-articular NGF-dependent mechanism. Although that ligament is innervated by nociceptors, it is unknown if a subpopulation is exclusively responsible for the behavioral and spinal neuronal responses to intra-articular NGF and/or facet joint injury. This study ablated joint afferents using the neurotoxin saporin targeted to neurons involved in either peptidergic ([Sar(9),Met (O2)(11)]-substance P-saporin (SSP-Sap)) or non-peptidergic (isolectin B4-saporin (IB4-Sap)) signaling to investigate the contributions of those neuronal populations to facet-mediated pain. SSP-Sap, but not IB4-Sap, injected into the bilateral C6/C7 facet joints 14 days prior to an intra- articular NGF injection prevents NGF-induced mechanical and thermal hypersensitivity in the forepaws. Similarly, only SSP- Sap prevents the increase in mechanical forepaw stimulation- induced firing of spinal neurons after intra-articular NGF. In addition, intra-articular SSP-Sap prevents both behavioral hypersensitivity and upregulation of NGF in the dorsal root ganglion after a facet joint distraction that normally induces pain. These findings collectively suggest that disruption of peptidergic signaling within the joint may be a potential treatment for facet pain, as well as other painful joint conditions associated with elevated NGF, such as osteoarthritis. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  12. PAIN FROM INTRA-ARTICULAR NGF OR JOINT INJURY IN THE RAT REQUIRES CONTRIBUTIONS FROM PEPTIDERGIC JOINT AFFERENTS

    PubMed Central

    Kras, Jeffrey V.; Weisshaar, Christine L.; Pall, Parul S.; Winkelstein, Beth A.

    2015-01-01

    Non-physiological stretch of the cervical facet joint’s capsular ligament induces persistent behavioral hypersensitivity and spinal neuronal hyperexcitability via an intra-articular NGF-dependent mechanism. Although that ligament is innervated by nociceptors, it is unknown if a subpopulation is exclusively responsible for the behavioral and spinal neuronal responses to intra-articular NGF and/or facet joint injury. This study ablated joint afferents using the neurotoxin saporin targeted to neurons involved in either peptidergic ([Sar9,Met(O2)11]-substance P-saporin (SSP-Sap)) or non-peptidergic (isolectin B4-saporin (IB4-Sap)) signaling to investigate the contributions of those neuronal populations to facet-mediated pain. SSP-Sap, but not IB4-Sap, injected into the bilateral C6/C7 facet joints 14 days prior to an intra-articular NGF injection prevents NGF-induced mechanical and thermal hypersensitivity in the forepaws. Similarly, only SSP-Sap prevents the increase in mechanical forepaw stimulation-induced firing of spinal neurons after intra-articular NGF. In addition, intra-articular SSP-Sap prevents both behavioral hypersensitivity and upregulation of NGF in the dorsal root ganglion after a facet joint distraction that normally induces pain. These findings collectively suggest that disruption of peptidergic signaling within the joint may be a potential treatment for facet pain, as well as other painful joint conditions associated with elevated NGF, such as osteoarthritis. PMID:26240991

  13. Fluoroscopic caudal epidural injections in managing chronic axial low back pain without disc herniation, radiculitis, or facet joint pain

    PubMed Central

    Manchikanti, Laxmaiah; Cash, Kimberly A; McManus, Carla D; Pampati, Vidyasagar

    2012-01-01

    Background Chronic low back pain without disc herniation is common. Various modalities of treatments are utilized in managing this condition, including epidural injections. However, there is continued debate on the effectiveness, indications, and medical necessity of any treatment modality utilized for managing axial or discogenic pain, including epidural injections. Methods A randomized, double-blind, actively controlled trial was conducted. The objective was to evaluate the ability to assess the effectiveness of caudal epidural injections of local anesthetic with or without steroids for managing chronic low back pain not caused by disc herniation, radiculitis, facet joints, or sacroiliac joints. A total of 120 patients were randomized to two groups; one group did not receive steroids (group 1) and the other group did (group 2). There were 60 patients in each group. The primary outcome measure was at least 50% improvement in Numeric Rating Scale and Oswestry Disability Index. Secondary outcome measures were employment status and opioid intake. These measures were assessed at 3, 6, 12, 18, and 24 months after treatment. Results Significant pain relief and functional status improvement (primary outcome) defined as a 50% or more reduction in scores from baseline, were observed in 54% of patients in group 1 and 60% of patients in group 2 at 24 months. In contrast, 84% of patients in group 1 and 73% in group 2 saw significant pain relief and functional status improvement in the successful groups at 24 months. Conclusion Caudal epidural injections of local anesthetic with or without steroids are effective in patients with chronic axial low back pain of discogenic origin without facet joint pain, disc herniation, and/or radiculitis. PMID:23091395

  14. A Prospective Study Comparing Platelet-Rich Plasma and Local Anesthetic (LA)/Corticosteroid in Intra-Articular Injection for the Treatment of Lumbar Facet Joint Syndrome.

    PubMed

    Wu, Jiuping; Zhou, Jingjing; Liu, Chibing; Zhang, Jun; Xiong, Wei; Lv, Yang; Liu, Rui; Wang, Ruiqiang; Du, Zhenwu; Zhang, Guizhen; Liu, Qinyi

    2017-09-01

    To compare the effectiveness and safety between autologous platelet-rich plasma (PRP) and Local Anesthetic (LA)/corticosteroid in intra-articular injection for the treatment of lumbar facet joint syndrome. Forty-six eligible patients with lumbar facet joint syndrome were randomized into group A (intra-articular injection with PRP) and group B (intra-articular injection with LA/corticosteroid). The following contents were evaluated: pain visual analog scale (VAS) at rest and during flexion, and the Roland-Morris Disability Questionnaire (RMQ), Oswestry Disability Index (ODI), and modified MacNab criteria for pain relief and applications of post-treatment drugs. All outcome assessments were performed immediately after and at 1 week, 1, 2, 3, and 6 months after treatment. No significant difference between groups was observed at baseline. Compared with pretreatment, both group A and group B demonstrated statistical improvements in the pain VAS score at rest or during flexion, the RMQ, and the ODI (P < 0.01). And there were significant differences between the 2 groups on the above-mentioned items (P < 0.05). For group B, subjective satisfaction based on the modified MacNab criteria and objective success rate were highest (80% and 85%) after 1 month, but only 50% and 20% after 6 months. However, for group A, they increased over time. In addition, there were no treatment-related complications in either group during follow-up. Both autologous PRP and LA/corticosteroid for intra-articular injection are effective, easy, and safe enough in the treatment of lumbar facet joint syndrome. However, autologous PRP is a superior treatment option for longer duration efficacy. © 2016 World Institute of Pain.

  15. Facet joint injections for people with persistent non-specific low back pain (Facet Injection Study): a feasibility study for a randomised controlled trial.

    PubMed

    Ellard, David R; Underwood, Martin; Achana, Felix; Antrobus, James Hl; Balasubramanian, Shyam; Brown, Sally; Cairns, Melinda; Griffin, James; Griffiths, Frances; Haywood, Kirstie; Hutchinson, Charles; Lall, Ranjit; Petrou, Stavros; Stallard, Nigel; Tysall, Colin; Walsh, David A; Sandhu, Harbinder

    2017-05-01

    The National Institute for Health and Care Excellence (NICE) 2009 guidelines for persistent low back pain (LBP) do not recommend the injection of therapeutic substances into the back as a treatment for LBP because of the absence of evidence for their effectiveness. This feasibility study aimed to provide a stable platform that could be used to evaluate a randomised controlled trial (RCT) on the clinical effectiveness and cost-effectiveness of intra-articular facet joint injections (FJIs) when added to normal care. To explore the feasibility of running a RCT to test the hypothesis that, for people with suspected facet joint back pain, adding the option of intra-articular FJIs (local anaesthetic and corticosteroids) to best usual non-invasive care is clinically effective and cost-effective. The trial was a mixed design. The RCT pilot protocol development involved literature reviews and a consensus conference followed by a randomised pilot study with an embedded mixed-methods process evaluation. Five NHS acute trusts in England. Participants were patients aged ≥ 18 years with moderately troublesome LBP present (> 6 months), who had failed previous conservative treatment and who had suspected facet joint pain. The study aimed to recruit 150 participants (approximately 30 per site). Participants were randomised sequentially by a remote service to FJIs combined with 'best usual care' (BUC) or BUC alone. All participants were to receive six sessions of a bespoke BUC rehabilitation package. Those randomised into the intervention arm were, in addition, given FJIs with local anaesthetic and steroids (at up to six injection sites). Randomisation occurred at the end of the first BUC session. Process and clinical outcomes. Clinical outcomes included a measurement of level of pain on a scale from 0 to 10, which was collected daily and then weekly via text messaging (or through a written diary). Questionnaire follow-up was at 3 months. Fifty-two stakeholders attended the

  16. Intraarticular Facet Injections for Low Back Pain: Design Considerations, Consensus Methodology to Develop the Protocol for a Randomized Controlled Trial.

    PubMed

    Mars, Tom; Ellard, David R; Antrobus, James H L; Cairns, Melinda; Underwood, Martin; Haywood, Kirstie; Keohane, Susie; Sandhu, Harbinder; Griffiths, Frances

    2015-01-01

    Since the publication of guidelines by the UK National Institute for Health and Care Excellence (NICE) and the American Pain Society guidelines for low back pain in 2009 there have been deep divisions in the pain treatment community about the use of therapeutic intraarticular facet joint injections. While evidence for the effectiveness or not of intraarticular facet joint injections remains sparse, uncertainty will remain. The Warwick feasibility study, along with a concurrent study with a different design led by another group, aims to provide a stable platform from which the effectiveness and cost effectiveness of intraarticular facet joint injections added to normal care could be evaluated in randomized controlled trials (RCTs). To reach consensus on key design considerations for the Warwick facet feasibility study from which the study protocol and working manuals will be developed. A consensus conference involving expert professionals and lay members. Preliminary work identified 5 key design considerations for deliberation at our consensus conference. Three concerned patient assessment and treatment: diagnosis of possible facet joint pain, interaarticular facet joint injection technique, and best usual care. Two concerned trial analysis: a priori sub-groups and minimally important difference and are reported elsewhere. We did systematic evidence reviews of the design considerations and summarized the evidence. Our design questions and evidence summaries were distributed to all delegates. This formed the basis for discussions on the day. Clinical experts in all aspects of facet joint injection from across the UK along with lay people were invited via relevant organizations. Nominal group technique was used in 15 facilitated initial small group discussions. Further discussion and ranking was undertaken in plenary. All small group and plenary results were recorded and checked and verified post conference. Where necessary participants were contacted via email to

  17. PLIF with a titanium cage and excised facet joint bone for degenerative spondylolisthesis--in augmentation with a pedicle screw.

    PubMed

    Okuyama, Koichiro; Kido, Tadato; Unoki, Eiki; Chiba, Mitsuho

    2007-02-01

    To determine the validity of posterior lumbar interbody fusion (PLIF) using a titanium cage filled with excised facet joint bone and a pedicle screw for degenerative spondylolisthesis. PLIF using a titanium cage filled with excised facet joint bone and a pedicle screw was performed in 28 consecutive patients (men 10, women 18). The mean age of the patients was 60 years (range, 52 to 75 y) at the time of surgery. The mean follow-up period was 2.3 years (range, 2.0 to 4.5 y). The operation was done at L3/4 in 5, L4/5 in 20, and L3/4/5 in 3 patients. The mean operative bleeding was 318+/-151 g (mean+/-standard deviation), and the mean operative time was 3.34+/-0.57 hours per fixed segment. Clinical outcome was assessed by Denis' Pain and Work scale. Radiologic assessment was done using Boxell's method. Fusion outcome was assessed using an established criteria. On Pain scale, 20 and 8 patients were rated P4 and P5 before surgery, and 11, 12, 2, 2, and 1 patients were rated P1, P2, P3, P4, and P5 at final follow-up, respectively. On Work scale (for only physical labors), 12 and 9 patients were rated W4 and W5, before surgery, and 12, 5, 1, and 3 patients were rated W1, W2, W3 and W5 at final follow-up, respectively. There was significant difference in clinical outcome (P<0.01, Wilcoxon singled-rank test) The mean %Slip and Slip Angle was 17.9+/-8.1% and 3.9+/-5.8 degrees before surgery. The mean % Slip and Slip Angle was 5.4+/-4.4% and -2.0+/-4.8 degrees at final follow-up. There was a significant difference between the values (P<0.01, paired t test). "Union" and "probable union" was determined in 29 (93.5%) and 2 (6.5%) of 31 operated segments at 2.3 years (range, 2.0 to 4.5 y), postoperatively. PLIF using a titanium cage filled with excised facet joint bone and a pedicle screw provided a satisfactory clinical outcome and an excellent union rate without harvesting and grafting the autologous iliac bone.

  18. Neuroanatomical distribution of mechanoreceptors in the human cadaveric shoulder capsule and labrum

    PubMed Central

    Witherspoon, Jessica W; Smirnova, Irina V; McIff, Terence E

    2014-01-01

    The distribution, location, and spatial arrangement of mechanoreceptors are important for neural signal conciseness and accuracy in proprioceptive information required to maintain functional joint stability. The glenohumeral joint capsule and labrum are mechanoreceptor-containing tissues for which the distribution of mechanoreceptors has not been determined despite the importance of these tissues in stabilizing the shoulder. More recently, it has been shown that damage to articular mechanoreceptors can result in proprioceptive deficits that may lead to recurrent instability. Awareness of mechanoreceptor distribution in the glenohumeral joint capsule and labrum may allow preservation of the mechanoreceptors during surgical treatment for shoulder instability, and in turn retain the joint's proprioceptive integrity. For this reason, we sought to develop a neuroanatomical map of the mechanoreceptors within the capsule and labrum. We postulated that the mechanoreceptors in these tissues are distributed in a unique pattern, with mechanoreceptor-scarce regions that may be more appropriate for surgical dissection. We determined the neuroanatomical distribution of mechanoreceptors and their associated fascicles in the capsule and labrum from eight human cadaver shoulder pairs using our improved gold chloride staining technique and light microscopy. A distribution pattern was consistently observed in the capsule and labrum from which we derived a neuroanatomical map. Both tissues demonstrated mechanoreceptor-dense and -scarce regions that may be considered during surgical treatment for instability. Capsular fascicles were located in the subsynovial layer, whereas labral fascicles were concentrated in the peri-core zone. The capsular fascicles presented as a lattice network and with a plexiform appearance. Fascicles within the labrum resembled a cable structure with the fascicles running in parallel. Our findings contribute to the neuroanatomical knowledge of the two

  19. Fluoroscopic cervical epidural injections in chronic axial or disc-related neck pain without disc herniation, facet joint pain, or radiculitis

    PubMed Central

    Manchikanti, Laxmaiah; Cash, Kimberly A; Pampati, Vidyasagar; Malla, Yogesh

    2012-01-01

    Background While chronic neck pain is a common problem in the adult population, with a typical 12-month prevalence of 30%–50%, there is a lack of consensus regarding its causes and treatment. Despite limited evidence, cervical epidural injections are one of the commonly performed nonsurgical interventions in the management of chronic neck pain. Methods A randomized, double-blind, active, controlled trial was conducted to evaluate the effectiveness of cervical interlaminar epidural injections of local anesthetic with or without steroids for the management of chronic neck pain with or without upper extremity pain in patients without disc herniation, radiculitis, or facet joint pain. Results One hundred and twenty patients without disc herniation or radiculitis and negative for facet joint pain by means of controlled diagnostic medial branch blocks were randomly assigned to one of two treatment groups, ie, injection of local anesthetic only (group 1) or local anesthetic mixed with nonparticulate betamethasone (group 2). The primary outcome of significant pain relief and improvement in functional status (≥50%) was demonstrated in 72% of group 1 and 68% of group 2. The overall average number of procedures per year was 3.6 in both groups with an average total relief per year of 37–39 weeks in the successful group over a period of 52 weeks. Conclusion Cervical interlaminar epidural injections of local anesthetic with or without steroids may be effective in patients with chronic function-limiting discogenic or axial pain. PMID:22826642

  20. Radiological analysis of minimal safe distance and optimal screw angle to avoid facet violation in open-door laminoplasty using precontoured plate.

    PubMed

    Min, Woo-Kie; Seo, Il; Na, Sang-Bong; Choi, Young-Seo; Choi, Ji-Yeon

    2017-01-01

    This study aimed to present radiologic analysis of minimal safe distance (MSD) and optimal screw angle (OSA) that enables to fix screws in a lateral mass safely without facet joint violation in open-door laminoplasty using a plate. A retrospective analysis was made of 22 patients (male: 17; female: 5), average age 62 years. Seventy-nine lateral mass screws were fixed among a total of 158 screws. MSD that doesn't allow 5-mm screws to violate a facet joint was measured for C3-C7 and a comparative analysis was performed. If the MSD is not secured, the OSA to be given to the cephalad direction is calculated to avoid violation of the facet joint. The screws violating inferior facet joints accounted for 34.1% of the screws fixed in inferior lateral mass. Joint surface to distal mini-screw distances were 3.18 ± 1.46 mm and 4.75 ± 1.71 mm in groups of facet joint violation and non-facet violation (FV), respectively ( p = 0.001). When 5-mm screws were inserted into a lateral mass, MSD was 4.39 ± 0.83 mm. The average MSD of C3, C4, and C5 was 4.05 ± 0.78 mm, 4.10 ± 0.70 mm, and 4.26 ± 0.74 mm, respectively. There was no significant differences among levels ( p > 0.05). The average MSD of C6 and C7 was 4.92 ± 0.81 mm and 4.80 ± 0.96 mm, respectively, showing significant differences from those of C3, C4, and C5 ( p < 0.05). If 6 mm of the MSD isn't secured, OSA showed in the cephalad direction of 11.5° for 5 mm and 22° for 4 mm approximately. We suggest that mini-screw on lateral mass can be fixed safely without FV, if they are fixed at MSD of 6 mm from a joint surface. Facet joint violation doesn't occur if an OSA is given in the cephalad direction in case of not enough MSD for mini-screws.

  1. Facet orientation and tropism: Associations with asymmetric lumbar paraspinal and psoas muscle parameters in patients with chronic low back pain.

    PubMed

    Xu, W B; Chen, S; Fan, S W; Zhao, F D; Yu, X J; Hu, Z J

    2016-08-10

    Many studies have explored the relationship between facet tropism and facet joint osteoarthritis, disc degeneration and degenerative spondylolisthesis. However, the associations between facet orientation and tropism, and paraspinal muscles have not been studied. To analyze the associations between facet orientation and tropism, and parameters of paraspinal muscles in patients with chronic low back pain. Ninety-five patients with chronic low back pain were consecutively enrolled. Their facet joint angles were measured on computed tomography (CT) while gross cross-sectional area (GCSA), functional cross-sectional area (FCSA) and T2 signal intensity of lumbar paraspinal and psoas muscle were evaluated on magnetic resonance imaging (MRI). The GCSA and FCSA were significantly smaller for multifidus muscle (P< 0.001), but significantly larger for erector spinae and psoas muscles (P< 0.001), in coronally-orientated group than those in sagittally-orientated group. The differences of bilateral GCSA and FCSA of multifidus muscle were significantly larger in facet tropism group than those in no facet tropism group (P= 0.009 and P= 0.019). Muscular asymmetries may develop in the lumbar region of the spine, which are associated with facet asymmetry in patients with chronic low back pain. Longitudinal studies are needed to understand the causal relationship between facet orientation and tropism and muscular asymmetry in future.

  2. Clinical diagnosis scale for pain lumbar of facet origin: systematic review of literature and pilot study.

    PubMed

    Gómez Vega, Juan Carlos; Acevedo-González, Juan Carlos

    2018-06-14

    Lumbar pain affects between 60-90% of people. It is a frequent cause of disability in adults. Pain may be generated by different anatomical structures such as the facet joint. However, nowadays pain produced by the facet joint has no clinical diagnosis. Therefore, the purpose of this article is to propose a clinical diagnostic scale for lumbar facet syndrome. The study was conducted by means of 6 phases as follows, Phase 1, a systematic review of the literature was performed regarding the clinical diagnosis of facet-based lumbar pain based on the PRISMA checklist; Phase 2, a list of signs and symptoms proposed for diagnosis lumbar pain of facet origin was made. Phase 3, the list of signs and symptoms found was submitted to a committee of experts to discriminate the most significant signs and symptoms, these were linked to general sociodemographic variables to develop an evaluation questionnaire; Phase 4, the evaluation questionnaire was applied, including those selected signs and symptoms to a group of patients with clinical diagnosis of facet disease lumbar pain and who underwent a selective facet block. Phase 5, under standard technique selective facet block and subsequent postoperative clinical control at 1 month. Phase 6, given pre and postsurgical results associated with signs present in the patients we propose a clinical scale of diagnosis scale. Descriptive statistics and Stata 12.0 were used as statistical software. A total of 36 signs and symptoms were found for the diagnosis of lumbar facet syndrome that were submitted to the group of experts, where a total of 12 (8 symptoms and 4 signs) were included for the final survey. 31 patients underwent selective lumbar facet blockade, mostly women, with an average of 60±11.5 years, analogous visual scale of preoperative pain of 8/10, postoperative of 1.7/10, the signs and symptoms most frequently found included in a diagnostic scale were: 3 symptoms 1) axial or bilateral axial lumbar pain, 2) improvement with

  3. MultiFacet: A Faceted Interface for Browsing Large Multimedia Collections

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Henry, Michael J.; Hampton, Shawn D.; Endert, Alexander

    2013-10-31

    Faceted browsing is a common technique for exploring collections where the data can be grouped into a number of pre-defined categories, most often generated from textual metadata. Historically, faceted browsing has been applied to a single data type such as text or image data. However, typical collections contain multiple data types, such as information from web pages that contain text, images, and video. Additionally, when browsing a collection of images and video, facets are often created based on the metadata which may be incomplete, inaccurate, or missing altogether instead of the actual visual content contained within those images and video.more » In this work we address these limitations by presenting MultiFacet, a faceted browsing interface that supports multiple data types. MultiFacet constructs facets for images and video in a collection from the visual content using computer vision techniques. These visual facets can then be browsed in conjunction with text facets within a single interface to reveal relationships and phenomena within multimedia collections. Additionally, we present a use case based on real-world data, demonstrating the utility of this approach towards browsing a large multimedia data collection.« less

  4. Active multilayered capsules for in vivo bone formation

    PubMed Central

    Facca, S.; Cortez, C.; Mendoza-Palomares, C.; Messadeq, N.; Dierich, A.; Johnston, A. P. R.; Mainard, D.; Voegel, J.-C.; Caruso, F.; Benkirane-Jessel, N.

    2010-01-01

    Interest in the development of new sources of transplantable materials for the treatment of injury or disease has led to the convergence of tissue engineering with stem cell technology. Bone and joint disorders are expected to benefit from this new technology because of the low self-regenerating capacity of bone matrix secreting cells. Herein, the differentiation of stem cells to bone cells using active multilayered capsules is presented. The capsules are composed of poly-L-glutamic acid and poly-L-lysine with active growth factors embedded into the multilayered film. The bone induction from these active capsules incubated with embryonic stem cells was demonstrated in vitro. Herein, we report the unique demonstration of a multilayered capsule-based delivery system for inducing bone formation in vivo. This strategy is an alternative approach for in vivo bone formation. Strategies using simple chemistry to control complex biological processes would be particularly powerful, as they make production of therapeutic materials simpler and more easily controlled. PMID:20160118

  5. FACETS: multi-faceted functional decomposition of protein interaction networks.

    PubMed

    Seah, Boon-Siew; Bhowmick, Sourav S; Dewey, C Forbes

    2012-10-15

    The availability of large-scale curated protein interaction datasets has given rise to the opportunity to investigate higher level organization and modularity within the protein-protein interaction (PPI) network using graph theoretic analysis. Despite the recent progress, systems level analysis of high-throughput PPIs remains a daunting task because of the amount of data they present. In this article, we propose a novel PPI network decomposition algorithm called FACETS in order to make sense of the deluge of interaction data using Gene Ontology (GO) annotations. FACETS finds not just a single functional decomposition of the PPI network, but a multi-faceted atlas of functional decompositions that portray alternative perspectives of the functional landscape of the underlying PPI network. Each facet in the atlas represents a distinct interpretation of how the network can be functionally decomposed and organized. Our algorithm maximizes interpretative value of the atlas by optimizing inter-facet orthogonality and intra-facet cluster modularity. We tested our algorithm on the global networks from IntAct, and compared it with gold standard datasets from MIPS and KEGG. We demonstrated the performance of FACETS. We also performed a case study that illustrates the utility of our approach. Supplementary data are available at the Bioinformatics online. Our software is available freely for non-commercial purposes from: http://www.cais.ntu.edu.sg/~assourav/Facets/

  6. Closed Loop Control of a Tethered Magnetic Capsule Endoscope

    PubMed Central

    Taddese, Addisu Z.; Slawinski, Piotr R.; Obstein, Keith L.; Valdastri, Pietro

    2017-01-01

    Magnetic field gradients have repeatedly been shown to be the most feasible mechanism for gastrointestinal capsule endoscope actuation. An inverse quartic magnetic force variation with distance results in large force gradients induced by small movements of a driving magnet; this necessitates robotic actuation of magnets to implement stable control of the device. A typical system consists of a serial robot with a permanent magnet at its end effector that actuates a capsule with an embedded permanent magnet. We present a tethered capsule system where a capsule with an embedded magnet is closed loop controlled in 2 degree-of-freedom in position and 2 degree-of-freedom in orientation. Capitalizing on the magnetic field of the external driving permanent magnet, the capsule is localized in 6-D allowing for both position and orientation feedback to be used in a control scheme. We developed a relationship between the serial robot's joint parameters and the magnetic force and torque that is exerted onto the capsule. Our methodology was validated both in a dynamic simulation environment where a custom plug-in for magnetic interaction was written, as well as on an experimental platform. The tethered capsule was demonstrated to follow desired trajectories in both position and orientation with accuracy that is acceptable for colonoscopy. PMID:28286886

  7. Closed Loop Control of a Tethered Magnetic Capsule Endoscope.

    PubMed

    Taddese, Addisu Z; Slawinski, Piotr R; Obstein, Keith L; Valdastri, Pietro

    2016-06-01

    Magnetic field gradients have repeatedly been shown to be the most feasible mechanism for gastrointestinal capsule endoscope actuation. An inverse quartic magnetic force variation with distance results in large force gradients induced by small movements of a driving magnet; this necessitates robotic actuation of magnets to implement stable control of the device. A typical system consists of a serial robot with a permanent magnet at its end effector that actuates a capsule with an embedded permanent magnet. We present a tethered capsule system where a capsule with an embedded magnet is closed loop controlled in 2 degree-of-freedom in position and 2 degree-of-freedom in orientation. Capitalizing on the magnetic field of the external driving permanent magnet, the capsule is localized in 6-D allowing for both position and orientation feedback to be used in a control scheme. We developed a relationship between the serial robot's joint parameters and the magnetic force and torque that is exerted onto the capsule. Our methodology was validated both in a dynamic simulation environment where a custom plug-in for magnetic interaction was written, as well as on an experimental platform. The tethered capsule was demonstrated to follow desired trajectories in both position and orientation with accuracy that is acceptable for colonoscopy.

  8. Effect of Retrograde Reaming for Tibiotalocalcaneal Arthrodesis on Subtalar Joint Destruction: A Cadaveric Study.

    PubMed

    Lowe, Jason A; Routh, Lucas K; Leary, Jeffrey T; Buzhardt, Paul C

    2016-01-01

    Recent published data have suggested successful union of subtalar and tibiotalar joints without formal debridement during tibiotalocalcaneal (TTC) fusion procedures. Although previous studies have reported on the importance of the proper guidewire starting point and trajectory to obtain appropriate hindfoot alignment for successful fusion, to our knowledge, no studies have quantified the amount of articular damage to the subtalar joint with retrograde reaming. We hypothesized that reaming would destroy >50% of the posterior facet of the subtalar joint. The bilateral lower extremities of 5 cadavers were obtained and the subtalar joints exposed. Retrograde TTC nail guidewires were inserted, and a 12-mm reamer was passed through the subtalar and ankle joints. Pre- and postreaming images of the subtalar joint were obtained to compare the amount of joint destruction after reaming. We found an average of 5.89% articular destruction of the talar posterior facet and an average of 4.01% articular destruction of the posterior facet of the calcaneus. No damage to the middle facets of the subtalar joint was observed. TTC nailing is a successful procedure for ankle and subtalar joint fusion. Published studies have reported successful subtalar union using TTC nailing without formal open debridement of the subtalar joint, preserving the soft tissue envelope. TTC nail insertion using a 12-mm reamer will destroy 5.89% and 4.01% of the respective talar and calcaneal posterior facets of the subtalar joint. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  9. FACETS: multi-faceted functional decomposition of protein interaction networks

    PubMed Central

    Seah, Boon-Siew; Bhowmick, Sourav S.; Forbes Dewey, C.

    2012-01-01

    Motivation: The availability of large-scale curated protein interaction datasets has given rise to the opportunity to investigate higher level organization and modularity within the protein–protein interaction (PPI) network using graph theoretic analysis. Despite the recent progress, systems level analysis of high-throughput PPIs remains a daunting task because of the amount of data they present. In this article, we propose a novel PPI network decomposition algorithm called FACETS in order to make sense of the deluge of interaction data using Gene Ontology (GO) annotations. FACETS finds not just a single functional decomposition of the PPI network, but a multi-faceted atlas of functional decompositions that portray alternative perspectives of the functional landscape of the underlying PPI network. Each facet in the atlas represents a distinct interpretation of how the network can be functionally decomposed and organized. Our algorithm maximizes interpretative value of the atlas by optimizing inter-facet orthogonality and intra-facet cluster modularity. Results: We tested our algorithm on the global networks from IntAct, and compared it with gold standard datasets from MIPS and KEGG. We demonstrated the performance of FACETS. We also performed a case study that illustrates the utility of our approach. Contact: seah0097@ntu.edu.sg or assourav@ntu.edu.sg Supplementary information: Supplementary data are available at the Bioinformatics online. Availability: Our software is available freely for non-commercial purposes from: http://www.cais.ntu.edu.sg/∼assourav/Facets/ PMID:22908217

  10. Facet orientation in the thoracolumbar spine: three-dimensional anatomic and biomechanical analysis.

    PubMed

    Masharawi, Youssef; Rothschild, Bruce; Dar, Gali; Peleg, Smadar; Robinson, Dror; Been, Ella; Hershkovitz, Israel

    2004-08-15

    Thoracolumbar facet orientations were measured and analyzed. To establish a comprehensive database for facet orientation in the thoracolumbar vertebrae and to determine the normal human condition. Most studies on facet orientation have based their conclusions on two-dimensional measurements, in small samples or isolated vertebrae. The amount of normal asymmetry in facet orientation is poorly addressed. Transverse and longitudinal facet angles were measured directly from 240 human vertebral columns (males/females, blacks/whites). The specimens' osteologic material is part of the Hamann-Todd Osteological Collection housed at the Cleveland Museum of Natural History (Cleveland, OH). A total of 4,080 vertebrae (T1-L5) from the vertebral columns of individuals 20 to 80 years of age were measured, using a Microscribe three-dimensional apparatus (Immersion Co., San Jose, CA). Data were recorded directly on computer software. Statistical analysis included paired t tests and analysis of variance. RESULTS.: Facet orientation is independent of gender, age, and ethnic group. Asymmetry in facet orientation is found in the thorax. All thoracolumbar facets are positioned in an oblique plane. In the transverse plane, all facets from T1 to T11 are positioned with an anterior inclination of approximately 25 degrees to 30 degrees from the frontal plane. The facets of T12-L2 are oriented closer to the midsagittal plane of the vertebral body (mean range, 25.89 degrees-33.87 degrees), while the facets of L3-L5 are oriented away from that plane (mean range, 40.40 degrees-56.30 degrees). Facet transverse orientation at the thoracolumbar junction is highly variable (approximately 80% with approximately 101 degrees and approximately 20% with 35 degrees). All facets are oriented more vertically from T1 (approximately 150 degrees) to L5 (approximately 170 degrees). The facet sagittal orientations of the lumbar zygoapophyseal joints are not equivalent. CONCLUSIONS.: Asymmetry in facet

  11. Effect of Stretching Combined With Ultrashort Wave Diathermy on Joint Function and Its Possible Mechanism in a Rabbit Knee Contracture Model.

    PubMed

    Zhang, Quan Bing; Zhou, Yun; Zhong, Hua Zhang; Liu, Yi

    2018-05-01

    The aim of this study was to investigate the therapeutic effect of stretching combined with ultrashort wave on joint contracture and explore its possible mechanism. Thirty-two rabbits underwent unilateral immobilization of a knee joint at full extension to cause joint contracture. At 6 wks after immobilization, the rabbits were randomly divided into the following four groups: natural recovery group, stretching treatment group, ultrashort wave treatment group, and combined treatment group. For comparison, eight control group animals of corresponding age were also examined. The effect of stretching and ultrashort wave treatment on joint contracture was assessed by measuring the joint range of motion, evaluating the collagen deposition of joint capsule and assessing the mRNA and protein levels for transforming growth factor β1 in the joint capsule. The combined treatment group led to the best recovery of joint function. The combined treatment with stretching and ultrashort wave was more effective than stretching or ultrashort wave treatment alone against the synovial thickening of suprapatellar joint capsule, the collagen deposition of anterior joint capsule, and the elevated expression of transforming growth factor β1 in the joint capsule. Stretching combined with ultrashort wave treatment was effective in improving joint range of motion, reducing the biomechanical, histological, and molecular manifestations of joint capsule fibrosis in a rabbit model of extending joint contracture.

  12. Development and Validation of the Faceted Inventory of the Five-Factor Model (FI-FFM).

    PubMed

    Watson, David; Nus, Ericka; Wu, Kevin D

    2017-06-01

    The Faceted Inventory of the Five-Factor Model (FI-FFM) is a comprehensive hierarchical measure of personality. The FI-FFM was created across five phases of scale development. It includes five facets apiece for neuroticism, extraversion, and conscientiousness; four facets within agreeableness; and three facets for openness. We present reliability and validity data obtained from three samples. The FI-FFM scales are internally consistent and highly stable over 2 weeks (retest rs ranged from .64 to .82, median r = .77). They show strong convergent and discriminant validity vis-à-vis the NEO, the Big Five Inventory, and the Personality Inventory for DSM-5. Moreover, self-ratings on the scales show moderate to strong agreement with corresponding ratings made by informants ( rs ranged from .26 to .66, median r = .42). Finally, in joint analyses with the NEO Personality Inventory-3, the FI-FFM neuroticism facet scales display significant incremental validity in predicting indicators of internalizing psychopathology.

  13. Systematic review and meta-analysis of the efficacy and safety of Biqi capsule in rheumatoid arthritis patients.

    PubMed

    Chen, Xiu-Min; Wu, Jia-Qi; Huang, Qing-Chun; Zhang, Jian-Yong; Pen, Jian-Hong; Huang, Zhi-Sheng; Chu, Yong-Liang; He, Xiao-Hong; Wang, Mao-Jie; Huang, Run-Yue

    2018-06-01

    Biqi capsule is a Traditional Chinese Medicine preparation for treating rheumatoid arthritis (RA), and clinical studies have indicatedthat its effect may be more beneficial than that of Western medicine. The present study aimed to estimate the efficacy and safety of Biqi capsule alone or combined with methotrexate (MTX) compared with MTX alone for treating RA by performing a meta-analysis of randomized controlled trials and controlled clinical trials. A systematic literature search of studies published until March 2017 was performed. References from relevant studies were screened to obtain additional articles. The results were independently evaluated for relevance, and full-text studies were assessed for eligibility. The risk of bias was assessed using the Cochrane collaboration tool for assessing risk of bias. Out of 558 citations that were initially retrieved, a total of 5 studies comprising 522 patients met the inclusion criteria. The risk of bias of these trials was generally unclear or high. Meta-analysis indicated that Biqi capsule had better effects on C-reactive protein [standardized mean difference (SMD), -7.05; 95% CI -(10.77-3.33)] and tender joint count [SMD, -3.02; 95% CI, -(3.81-2.22)] and fewer adverse effects (AEs) than MTX [relative risk (RR), 0.19; 95% CI, 0.08-0.43]. Biqi capsule plus MTX was superior to MTX in terms of the total effect (RR, 1.17; 95% CI, 1.06-1.28), rheumatoid factor [SMD, -12.54; 95% CI, -(16.87-8.20)], swollen joint count [SMD, -1.50; 95% CI, -(1.99-1.01)], score of joint swelling [SMD -2.07; 95% CI, -(2.76-1.38)], tender joint count [SMD, -2.16; 95% CI, -(2.86-1.47)] and score of joint tenderness [SMD, -4.69; 95% CI, -(5.92-3.47)]. There was no difference in AEs between Biqi capsule plus MTX and MTX (RR, 0.71; 95% CI, 0.34-1.50). In conclusion, the present study indicated that compared with MTX, Biqi capsule plus MTX appeared to have more benefits but that Biqi capsule alone was not better for RA patients than MTX. In the

  14. Cadaveric Study of the Articular Branches of the Shoulder Joint.

    PubMed

    Eckmann, Maxim S; Bickelhaupt, Brittany; Fehl, Jacob; Benfield, Jonathan A; Curley, Jonathan; Rahimi, Ohmid; Nagpal, Ameet S

    This cadaveric study investigated the anatomic relationships of the articular branches of the suprascapular (SN), axillary (AN), and lateral pectoral nerves (LPN), which are potential targets for shoulder analgesia. Sixteen embalmed cadavers and 1 unembalmed cadaver, including 33 shoulders total, were dissected. Following dissections, fluoroscopic images were taken to propose an anatomical landmark to be used in shoulder articular branch blockade. Thirty-three shoulders from 17 total cadavers were studied. In a series of 16 shoulders, 16 (100%) of 16 had an intact SN branch innervating the posterior head of the humerus and shoulder capsule. Suprascapular sensory branches coursed laterally from the spinoglenoid notch then toward the glenohumeral joint capsule posteriorly. Axillary nerve articular branches innervated the posterolateral head of the humerus and shoulder capsule in the same 16 (100%) of 16 shoulders. The AN gave branches ascending circumferentially from the quadrangular space to the posterolateral humerus, deep to the deltoid, and inserting at the inferior portion of the posterior joint capsule. In 4 previously dissected and 17 distinct shoulders, intact LPNs could be identified in 14 (67%) of 21 specimens. Of these, 12 (86%) of 14 had articular branches innervating the anterior shoulder joint, and 14 (100%) of 14 LPN articular branches were adjacent to acromial branches of the thoracoacromial blood vessels over the superior aspect of the coracoid process. Articular branches from the SN, AN, and LPN were identified. Articular branches of the SN and AN insert into the capsule overlying the glenohumeral joint posteriorly. Articular branches of the LPN exist and innervate a portion of the anterior shoulder joint.

  15. Capsule endoscopy

    MedlinePlus

    Capsule enteroscopy; Wireless capsule endoscopy; Video capsule endoscopy (VCE); Small bowel capsule endoscopy (SBCE) ... a computer and software turns them into a video. Your provider watches the video to look for ...

  16. Influence of capsule shell composition on the performance indicators of hypromellose capsule in comparison to hard gelatin capsules.

    PubMed

    Al-Tabakha, Moawia M; Arida, Adi Issam; Fahelelbom, Khairi M S; Sadek, Bassem; Saeed, Dima Ahmed; Abu Jarad, Rami A; Jawadi, Jeevani

    2015-01-01

    The purpose of this study was to assess the in vitro performances of "vegetable" capsules in comparison to hard gelatin capsules in terms of shell weight variation, reaction to different humidity conditions, resistance to stress in the absence of moisture, powder leakage, disintegration and dissolution. Two types of capsules made of HPMC produced with (Capsule 2) or without (Capsule 3) a gelling agent and hard gelatin capsules (Capsule 1) were assessed. Shell weight variability was relatively low for all tested capsules shells. Although Capsule 1 had the highest moisture content under different humidity conditions, all capsule types were unable to protect the encapsulated hygroscopic polyvinylpyrrolidone (PVP) powder from surrounding humidity. The initial disintegration for all Capsule 1 occurred within 3 min, but for other types of capsules within 6 min (n = 18). Dissolution of acetaminophen was better when the deionized water (DIW) temperature increased from 32 to 42 °C in case of Capsule 1, but the effect of temperature was not significant for the other types of capsules. Acetaminphen dissolution from Capsule 1 was the fastest (i.e. >90% in 10 min) and independent of the media pH or contents unlike Capsule 2 which was influenced by the pH and dissolution medium contents. It is feasible to use hypromellose capsules shells with or without gelling agent for new lines of pharmaceutical products, however, there is a window for capsule shells manufacturing companies to improve the dissolution of their hypromellose capsules to match the conventional gelatin capsule shells and eventually replace them.

  17. Facet-Selective Epitaxy of Compound Semiconductors on Faceted Silicon Nanowires.

    PubMed

    Mankin, Max N; Day, Robert W; Gao, Ruixuan; No, You-Shin; Kim, Sun-Kyung; McClelland, Arthur A; Bell, David C; Park, Hong-Gyu; Lieber, Charles M

    2015-07-08

    Integration of compound semiconductors with silicon (Si) has been a long-standing goal for the semiconductor industry, as direct band gap compound semiconductors offer, for example, attractive photonic properties not possible with Si devices. However, mismatches in lattice constant, thermal expansion coefficient, and polarity between Si and compound semiconductors render growth of epitaxial heterostructures challenging. Nanowires (NWs) are a promising platform for the integration of Si and compound semiconductors since their limited surface area can alleviate such material mismatch issues. Here, we demonstrate facet-selective growth of cadmium sulfide (CdS) on Si NWs. Aberration-corrected transmission electron microscopy analysis shows that crystalline CdS is grown epitaxially on the {111} and {110} surface facets of the Si NWs but that the Si{113} facets remain bare. Further analysis of CdS on Si NWs grown at higher deposition rates to yield a conformal shell reveals a thin oxide layer on the Si{113} facet. This observation and control experiments suggest that facet-selective growth is enabled by the formation of an oxide, which prevents subsequent shell growth on the Si{113} NW facets. Further studies of facet-selective epitaxial growth of CdS shells on micro-to-mesoscale wires, which allows tuning of the lateral width of the compound semiconductor layer without lithographic patterning, and InP shell growth on Si NWs demonstrate the generality of our growth technique. In addition, photoluminescence imaging and spectroscopy show that the epitaxial shells display strong and clean band edge emission, confirming their high photonic quality, and thus suggesting that facet-selective epitaxy on NW substrates represents a promising route to integration of compound semiconductors on Si.

  18. Anti-inflammatory and antinociceptive effects of Chinese medicine SQ gout capsules and its modulation of pro-inflammatory cytokines focusing on gout arthritis.

    PubMed

    Kodithuwakku, Nandani Darshika; Pan, Min; Zhu, Yi-lin; Zhang, Yan-yan; Feng, Yi-dong; Fang, Wei-rong; Li, Yun-man

    2013-12-12

    Shuang-Qi gout capsule is a traditional Chinese medicine prescription, which has been used in the treatment of joint pain, inflammation and gout arthritis. This study evaluates anti-inflammatory and antinociceptive effects of Shuang-Qi gout capsule and its modulation of pro-inflammatory cytokines with special reference to gout arthritis. Anti-inflammatory effect of Shuang-Qi gout capsule was investigated bymice tail-flick response, acetic acid induced writhing response, Xylene-induced auricle inflammation and the hind paw volume of the monosodium urate (MSU) crystal induced rats with different time durations. To investigate the effects on gout arthritis, ankle joint of rats induced by MSU crystals and assessed for edema and histopathological changes. In vitro, prepared serum was incubated with urate crystal induced HUVE cells and the release of TNF-α and IL-1β determined by ELISA. Shuang-Qi gout capsule showed significant and dose dependent anti-inflammatory effect via reducing edema and pain, throughout all the models. The high dose of Shuang-Qi gout capsule and Indomethacin significantly attenuated the edema. Histopathological results showed that high and medium dose of Shuang-Qi gout capsule and Indomethacin reduced gouty joint inflammatory features, while the high dose of Shuang-Qi gout capsule showed a better therapeutic effect. High and medium dose of Shuang-Qi gout capsule significantly reduced the release of TNF-α and IL-1β (p<0.05). Shuang-Qi gout capsule can effectively inhibit the inflammation, analgesia, through the modulation of emission of pro-inflammatory cytokines and the curative effect is dose dependent. Conversely, these MSU induced in vivo and in vitro studies of Shuang-Qi gout capsule suggest that, Shuang-Qi gout capsule may be a potential agent for treatment in gouty arthritis. © 2013 Published by Elsevier Ireland Ltd.

  19. The effect of augmented reality training on percutaneous needle placement in spinal facet joint injections.

    PubMed

    Yeo, Caitlin T; Ungi, Tamas; U-Thainual, Paweena; Lasso, Andras; McGraw, Robert C; Fichtinger, Gabor

    2011-07-01

    The purpose of this study was to determine if augmented reality image overlay and laser guidance systems can assist medical trainees in learning the correct placement of a needle for percutaneous facet joint injection. The Perk Station training suite was used to conduct and record the needle insertion procedures. A total of 40 volunteers were randomized into two groups of 20. 1) The Overlay group received a training session that consisted of four insertions with image and laser guidance, followed by two insertions with laser overlay only. 2) The Control group received a training session of six classical freehand insertions. Both groups then conducted two freehand insertions. The movement of the needle was tracked during the series of insertions. The final insertion procedure was assessed to determine if there was a benefit to the overlay method compared to the freehand insertions. The Overlay group had a better success rate (83.3% versus 68.4%, p=0.002), and potential for less tissue damage as measured by the amount of needle movement inside the phantom (3077.6 mm(2) versus 5607.9 mm(2) , p =0.01). These results suggest that an augmented reality overlay guidance system can assist medical trainees in acquiring technical competence in a percutaneous needle insertion procedure. © 2011 IEEE

  20. A Cervico-Thoraco-Lumbar Multibody Dynamic Model for the Estimation of Joint Loads and Muscle Forces.

    PubMed

    Khurelbaatar, Tsolmonbaatar; Kim, Kyungsoo; Hyuk Kim, Yoon

    2015-11-01

    Computational musculoskeletal models have been developed to predict mechanical joint loads on the human spine, such as the forces and moments applied to vertebral and facet joints and the forces that act on ligaments and muscles because of difficulties in the direct measurement of joint loads. However, many whole-spine models lack certain elements. For example, the detailed facet joints in the cervical region or the whole spine region may not be implemented. In this study, a detailed cervico-thoraco-lumbar multibody musculoskeletal model with all major ligaments, separated structures of facet contact and intervertebral disk joints, and the rib cage was developed. The model was validated by comparing the intersegmental rotations, ligament tensile forces, facet joint contact forces, compressive and shear forces on disks, and muscle forces were to those reported in previous experimental and computational studies both by region (cervical, thoracic, or lumbar regions) and for the whole model. The comparisons demonstrated that our whole spine model is consistent with in vitro and in vivo experimental studies and with computational studies. The model developed in this study can be used in further studies to better understand spine structures and injury mechanisms of spinal disorders.

  1. Zeroing In on Mindfulness Facets: Similarities, Validity, and Dimensionality across Three Independent Measures.

    PubMed

    Siegling, Alex B; Petrides, K V

    2016-01-01

    The field of mindfulness has seen a proliferation of psychometric measures, characterised by differences in operationalisation and conceptualisation. To illuminate the scope of, and offer insights into, the diversity apparent in the burgeoning literature, two distinct samples were used to examine the similarities, validity, and dimensionality of mindfulness facets and subscales across three independent measures: the Five Facet Mindfulness Questionnaire (FFMQ), Philadelphia Mindfulness Scale (PHLMS), and Toronto Mindfulness Scale (TMS). Results revealed problematic associations of FFMQ Observe with the other FFMQ facets and supported a four-factor structure (omitting this facet), while disputing the originally envisaged five-factor model; thus, solidifying a pattern in the literature. Results also confirmed the bidimensional nature of the PHLMS and TMS subscales, respectively. A joint Confirmatory Factor Analysis showed that PHLMS Acceptance could be assimilated within the FFMQ's four-factor model (as a distinct factor). The study offers a way of understanding interrelationships between the available mindfulness scales, so as to help practitioners and researchers make a more informed choice when conceptualising and operationalising mindfulness.

  2. Zeroing In on Mindfulness Facets: Similarities, Validity, and Dimensionality across Three Independent Measures

    PubMed Central

    Siegling, Alex B.; Petrides, K. V.

    2016-01-01

    The field of mindfulness has seen a proliferation of psychometric measures, characterised by differences in operationalisation and conceptualisation. To illuminate the scope of, and offer insights into, the diversity apparent in the burgeoning literature, two distinct samples were used to examine the similarities, validity, and dimensionality of mindfulness facets and subscales across three independent measures: the Five Facet Mindfulness Questionnaire (FFMQ), Philadelphia Mindfulness Scale (PHLMS), and Toronto Mindfulness Scale (TMS). Results revealed problematic associations of FFMQ Observe with the other FFMQ facets and supported a four-factor structure (omitting this facet), while disputing the originally envisaged five-factor model; thus, solidifying a pattern in the literature. Results also confirmed the bidimensional nature of the PHLMS and TMS subscales, respectively. A joint Confirmatory Factor Analysis showed that PHLMS Acceptance could be assimilated within the FFMQ’s four-factor model (as a distinct factor). The study offers a way of understanding interrelationships between the available mindfulness scales, so as to help practitioners and researchers make a more informed choice when conceptualising and operationalising mindfulness. PMID:27055017

  3. Capsule Endoscope Aspiration after Repeated Attempts for Ingesting a Patency Capsule

    PubMed Central

    Mannami, Tomohiko; Ikeda, Genyo; Seno, Satoru; Sonobe, Hiroshi; Fujiwara, Nobukiyo; Komoda, Minori; Edahiro, Satoru; Ohtawa, Yasuyuki; Fujimoto, Yoshimi; Sato, Naohiro; Kambara, Takeshi; Waku, Toshihiko

    2015-01-01

    Capsule endoscope aspiration into the respiratory tract is a rare complication of capsule endoscopy. Despite the potential seriousness of this complication, no accepted methods exist to accurately predict and therefore prevent it. We describe the case of an 85-year-old male who presented for evaluation of iron deficiency anemia. He complained of dysphagia while ingesting a patency capsule, with several attempts over a period of 5 min before he was successful. Five days later, he underwent capsule endoscopy, where he experienced similar symptoms in swallowing the capsule. The rest of the examination proceeded uneventfully. On reviewing the captured images, the capsule endoscope was revealed to be aspirated, remaining in the respiratory tract for approximately 220 s before images of the esophagus and stomach appeared. To our knowledge, this is the first documented case of a patient who experienced capsule endoscope aspiration after ingestion of a patency capsule. This case suggests that repeated attempts required for ingesting the patency capsule can predict capsule endoscope aspiration. We presume that paying sufficient attention to the symptoms of a patient who ingests a patency capsule could help us prevent serious complications such as aspiration of the capsule endoscope. In addition, this experience implies the potential risk for ingesting the patency capsule. We must be aware that the patency capsule could also be aspirated and there may be more unrecognized aspiration cases. PMID:26600772

  4. Capsule Endoscope Aspiration after Repeated Attempts for Ingesting a Patency Capsule.

    PubMed

    Mannami, Tomohiko; Ikeda, Genyo; Seno, Satoru; Sonobe, Hiroshi; Fujiwara, Nobukiyo; Komoda, Minori; Edahiro, Satoru; Ohtawa, Yasuyuki; Fujimoto, Yoshimi; Sato, Naohiro; Kambara, Takeshi; Waku, Toshihiko

    2015-01-01

    Capsule endoscope aspiration into the respiratory tract is a rare complication of capsule endoscopy. Despite the potential seriousness of this complication, no accepted methods exist to accurately predict and therefore prevent it. We describe the case of an 85-year-old male who presented for evaluation of iron deficiency anemia. He complained of dysphagia while ingesting a patency capsule, with several attempts over a period of 5 min before he was successful. Five days later, he underwent capsule endoscopy, where he experienced similar symptoms in swallowing the capsule. The rest of the examination proceeded uneventfully. On reviewing the captured images, the capsule endoscope was revealed to be aspirated, remaining in the respiratory tract for approximately 220 s before images of the esophagus and stomach appeared. To our knowledge, this is the first documented case of a patient who experienced capsule endoscope aspiration after ingestion of a patency capsule. This case suggests that repeated attempts required for ingesting the patency capsule can predict capsule endoscope aspiration. We presume that paying sufficient attention to the symptoms of a patient who ingests a patency capsule could help us prevent serious complications such as aspiration of the capsule endoscope. In addition, this experience implies the potential risk for ingesting the patency capsule. We must be aware that the patency capsule could also be aspirated and there may be more unrecognized aspiration cases.

  5. Incidence of the coracoclavicular joint in South African populations.

    PubMed Central

    Nalla, S; Asvat, R

    1995-01-01

    The presence of a diarthrotic coracoclavicular joint, as represented by an articular facet on the conoid tubercle of the clavicle and the superior surface of the coracoid process of the scapula, was investigated. The sample consisted of 60 white and 180 black South African (60 Sotho, 60 Xhosa and 60 Zulu) skeletons. Each group consisted of 30 male and 30 female skeletons. The presence of the articular facet was recorded as either bilateral, unilateral left or unilateral right. The effect of clavicular length, scapular size and first rib angle on the presence of the coracoclavicular joint was also investigated. The presence of the articular facet was noted in 23 (9.6%) of the 240 individuals studied. Of these 23 individuals, 6 (26.1%) were white and 17 (73.9%) were black. Males (56.5%) presented a higher incidence of this anomaly than females (43.5%). The articular facet occurred bilaterally in 47.9% (11/23), unilaterally on the left in 30.4% (7/23) and unilaterally on the right in 21.7% (5/23). Sexual, racial and tribal differences were not statistically significant. Individuals possessing the joint showed statistically significantly (P < 0.01) larger scapulae (increased border lengths and superior angles), longer clavicles and longer first ribs. No statistically significant differences in the first rib angles were observed between individuals who possessed the joint and those who did not, thus implying similar thoracic inlet size. It is proposed that the aforementioned morphometry of the scapulae, clavicles and first ribs may restrict associated movements of the scapulae, resulting in the development of the coracoclavicular joint. Images Fig. 4 Fig. 5 PMID:7559137

  6. Experimental measurement and modeling analysis on mechanical properties of incudostapedial joint

    PubMed Central

    Zhang, Xiangming

    2011-01-01

    The incudostapedial (IS) joint between the incus and stapes is a synovial joint consisting of joint capsule, cartilage, and synovial fluid. The mechanical properties of the IS joint directly affect the middle ear transfer function for sound transmission. However, due to the complexity and small size of the joint, the mechanical properties of the IS joint have not been reported in the literature. In this paper, we report our current study on mechanical properties of human IS joint using both experimental measurement and finite element (FE) modeling analysis. Eight IS joint samples with the incus and stapes attached were harvested from human cadaver temporal bones. Tension, compression, stress relaxation and failure tests were performed on those samples in a micro-material testing system. An analytical approach with the hyperelastic Ogden model and a 3D FE model of the IS joint including the cartilage, joint capsule, and synovial fluid were employed to derive mechanical parameters of the IS joint. The comparison of measurements and modeling results reveals the relationship between the mechanical properties and structure of the IS joint. PMID:21061141

  7. Experimental measurement and modeling analysis on mechanical properties of incudostapedial joint.

    PubMed

    Zhang, Xiangming; Gan, Rong Z

    2011-10-01

    The incudostapedial (IS) joint between the incus and stapes is a synovial joint consisting of joint capsule, cartilage, and synovial fluid. The mechanical properties of the IS joint directly affect the middle ear transfer function for sound transmission. However, due to the complexity and small size of the joint, the mechanical properties of the IS joint have not been reported in the literature. In this paper, we report our current study on mechanical properties of human IS joint using both experimental measurement and finite element (FE) modeling analysis. Eight IS joint samples with the incus and stapes attached were harvested from human cadaver temporal bones. Tension, compression, stress relaxation and failure tests were performed on those samples in a micro-material testing system. An analytical approach with the hyperelastic Ogden model and a 3D FE model of the IS joint including the cartilage, joint capsule, and synovial fluid were employed to derive mechanical parameters of the IS joint. The comparison of measurements and modeling results reveals the relationship between the mechanical properties and structure of the IS joint.

  8. Dorsoradial capsulodesis for trapeziometacarpal joint instability.

    PubMed

    Rayan, Ghazi; Do, Viet

    2013-02-01

    We describe an alternative method for treating chronic trapeziometacarpal (TM) joint instability after acute injury or chronic repetitive use of the thumb by performing a dorsoradial capsulodesis procedure. The procedure is done by imbricating the redundant TM joint dorsoradial ligament and capsule after reducing the joint by pronating the thumb. The dorsoradial capsulodesis is a reasonable reconstructive option for chronic TM joint instability and subluxation. Copyright © 2013 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  9. Posterior Epidural Migration of an Extruded Lumbar Disc Mimicking a Facet Cyst: A Case Report

    PubMed Central

    Yoo, Young Sun; Ju, Chang Il; Kim, Dong Min

    2015-01-01

    Dorsal extradural migration of extruded disc material is clinically uncommon. We report a rare case of posterior epidural migration of an extruded lumbar disc mimicking a facet cyst. A 32-year-old man was admitted to our institute with a 2-week history of severe low back pain and radiating pain in the left leg. The magnetic resonance (MR) images revealed a dorsally located, left-sided extradural cystic mass at the L2-3 level. The initial diagnosis was an epidural facet cyst because of the high signal intensity on MR images and its location adjacent to the facet joint. Intraoperatively, an encapsulated mass of soft tissue adherent to the dural sac was observed and excised. The pathological diagnosis was degenerated disc material. After surgery, the patient experienced complete relief from leg pain. PMID:25883662

  10. Indian Hedgehog signaling pathway members are associated with magnetic resonance imaging manifestations and pathological scores in lumbar facet joint osteoarthritis.

    PubMed

    Shuang, Feng; Zhou, Ying; Hou, Shu-Xun; Zhu, Jia-Liang; Liu, Yan; Zhang, Chun-Li; Tang, Jia-Guang

    2015-05-20

    Indian Hedgehog (HH) has been shown to be involved in osteoarthritis (OA) in articular joints, where there is evidence that Indian HH blockade could ameliorate OA. It seems to play a prominent role in development of the intervertebral disc (IVD) and in postnatal maintenance. There is little work on IHH in the IVD. Hence the aim of the current study was to investigate the role of Indian Hedgehog in the pathology of facet joint (FJ) OA. 24 patients diagnosed with lumbar intervertebral disk herniation or degenerative spinal stenosis were included. Preoperative magnetic resonance imaging (MRI) and Osteoarthritis Research Society International (OARSI) histopathology grading system was correlated to the mRNA levels of GLI1, PTCH1, and HHIP in the FJs. The Weishaupt grading and OARSI scores showed high positive correlation (r = 0.894) (P < 0.01). MRI Weishaupt grades showed positive correlation with GLI1 (r = 0.491), PTCH1 (r = 0.444), and HHIP (r = 0.654) mRNA levels (P < 0.05 in each case). OARSI scores were also positively correlated with GLI1 (r = 0. 646), PTCH1 (r = 0. 518), and HHIP (r = 0.762) mRNA levels (P < 0.01 in each case). Cumulatively our findings indicate that Indian HH signaling is increased in OA and is perhaps a key component in OA pathogenesis and progression.

  11. Atlantoaxial manual realignment in a patient with traumatic atlantoaxial joint disruption.

    PubMed

    Goel, Atul; Figueiredo, Antonio; Maheshwari, Shradha; Shah, Abhidha

    2010-05-01

    We report a patient with complex traumatic translatory atlantoaxial dislocation, who we treated by joint exposure and reduction of the dislocation by facet manipulation and subsequent plate and screw atlantoaxial fixation. A 28-year-old male had fallen 7.6m (25 feet), and following the fall had severe neck pain but no neurological deficit. Investigations revealed a fracture at the base of the odontoid process and posterior displacement of the entire atlas over the axis, resulting in a translatory atlantoaxial dislocation. Head traction failed as he developed severe vertigo following its application. The patient was operated upon in a prone position. We opened the atlantoaxial joint and realigned the facets using distraction and manipulation techniques and secured the joint using a plate and screw interarticular method. The patient tolerated the treatment well and was symptom-free after 28 months. Postoperative images showed good craniovertebral alignment. Although technically challenging, direct manipulation of the facets of the atlas and axis can result in excellent craniovertebral realignment.

  12. Capsule injection system for a hydraulic capsule pipelining system

    DOEpatents

    Liu, Henry

    1982-01-01

    An injection system for injecting capsules into a hydraulic capsule pipelining system, the pipelining system comprising a pipeline adapted for flow of a carrier liquid therethrough, and capsules adapted to be transported through the pipeline by the carrier liquid flowing through the pipeline. The injection system comprises a reservoir of carrier liquid, the pipeline extending within the reservoir and extending downstream out of the reservoir, and a magazine in the reservoir for holding capsules in a series, one above another, for injection into the pipeline in the reservoir. The magazine has a lower end in communication with the pipeline in the reservoir for delivery of capsules from the magazine into the pipeline.

  13. Research study on neck injury lessening with active head restraint using human body FE model.

    PubMed

    Kitagawa, Yuichi; Yasuki, Tsuyoshi; Hasegawa, Junji

    2008-12-01

    The objective of this study is to examine the effectiveness of the active head restraint system in reducing neck injury risk of car occupants in low-speed rear impacts. A human body FE model "THUMS" was used to simulate head and neck kinematics of the occupant and to evaluate loading to the neck. Joint capsule strain was calculated to predict neck injury risk as well as NIC. The validity of the model was confirmed comparing its mechanical responses to those in human subjects in the literatures. Seat FE models were also prepared representing one with a fixed head restraint and the other one with an active head restraint system. The active head restraint system was designed to move the head restraint forward and upward when the lower unit was lower unit was loaded by the pelvis. Rear impact simulations were performed assuming a triangular acceleration pulse at a delta-V of 25 km/h. The model reproduced similar head and neck motions to those measured in the human volunteer test, except for active muscular responses. The calculated joint capsule strain also showed a good match with those of PMHS tests in the literature. A rear-impact simulation was conducted using the model with the fixed head restraint. The result revealed that NIC was strongly correlated with the relative acceleration between the head and the torso and that its maximum peak appeared when the head contacted the head restraint. It was also found that joint capsule strain grew in later timing synchronizing with the relative displacement. Another simulation with the active head restraint system showed that both NIC and joint capsule strain were lowered owing to the forward and upward motion of the head restraint. A close investigation of the vertebral motion indicated that the active head restraint reduced the magnitude of shear deformation in the facet joint, which contributed to the strain growth in the fixed head restraint case. Rear-impact simulations were conducted using a human body FE model, THUMS

  14. Facet control of gold nanorods

    DOE PAGES

    Zhang, Qingfeng; Han, Lili; Jing, Hao; ...

    2016-01-21

    While great success has been achieved in fine-tuning the aspect ratios and thereby the plasmon resonances of cylindrical Au nanorods, facet control with atomic level precision on the highly curved nanorod surfaces has long been a significantly more challenging task. The intrinsic structural complexity and lack of precise facet control of the nanorod surfaces remain the major obstacles for the atomic-level elucidation of the structure–property relationships that underpin the intriguing catalytic performance of Au nanorods. Here we demonstrate that the facets of single-crystalline Au nanorods can be precisely tailored using cuprous ions and cetyltrimethylammonium bromide as a unique pair ofmore » surface capping competitors to guide the particle geometry evolution during nanorod overgrowth. By deliberately maneuvering the competition between cuprous ions and cetyltrimethylammonium bromide, we have been able to create, in a highly controllable and selective manner, an entire family of nanorod-derived anisotropic multifaceted geometries whose surfaces are enclosed by specific types of well-defined high-index and low-index facets. This facet-controlled nanorod overgrowth approach also allows us to fine-tune the particle aspect ratios while well-preserving all the characteristic facets and geometric features of the faceted Au nanorods. Furthermore, taking full advantage of the combined structural and plasmonic tunability, we have further studied the facet-dependent heterogeneous catalysis on well-faceted Au nanorods using surface-enhanced Raman spectroscopy as an ultrasensitive spectroscopic tool with unique time-resolving and molecular finger-printing capabilities.« less

  15. Posterior subtalar joint synoviography and corticosteroid injection in rheumatoid arthritis.

    PubMed Central

    Beaudet, F; Dixon, A S

    1981-01-01

    Ten posterior subtalar joints of 8 patients with rheumatoid arthritis and 12 posterior subtalar joints of 6 cadavers were studied by contrast synoviography. In the rheumatoid group the abnormalities included posterior capsule distension, filling defects caused by hypertrophic synovitis, limited or irregular filling of the anterior recess of the joint in 5 out of 10, and communication with the ankle joint in 3 out of 10. None of the cadaveric joints showed posterior capsule distension or limited or irregular filling of the anterior recess of the joint, but communication with the ankle was present in 2 joints. The joints of the patients were injected with a 1:1 mixture of sodium iothalamate 70% (Conray 420) and triamcinolone hexacetonide (Lederspan) 20 mg/ml. All patients noticed a decrease in and an improvement in walking beginning 24-48 hours after the examination. Quantitative thermography was done immediately before and 1 after injection in 2 patients who showed an improvement in thermographic index. We conclude that hindfoot inflammatory pain arising from the posterior subtalar joint is caused by distension with hypertrophic synovitis which can be difficult to detect clinically. Images PMID:7224686

  16. Sacroiliac joint dysfunction.

    PubMed

    Ilaslan, Hakan; Arslan, Ahmet; Koç, Omer Nadir; Dalkiliç, Turker; Naderi, Sait

    2010-07-01

    Sacroiliac joint dysfunction is a disorder presenting with low back and groin pain. It should be taken into consideration during the preoperative differential diagnosis of lumbar disc herniation, lumbar spinal stenosis and facet syndrome. Four cases with sacroiliac dysfunction are presented. The clinical and radiological signs supported the evidence of sacroiliac dysfunction, and exact diagnosis was made after positive response to sacroiliac joint block. A percutaneous sacroiliac fixation provided pain relief in all cases. The mean VAS scores reduced from 8.2 to 2.2. It is concluded that sacroiliac joint dysfunction diagnosis requires a careful physical examination of the sacroiliac joints in all cases with low back and groin pain. The diagnosis is made based on positive response to the sacroiliac block. Sacroiliac fixation was found to be effective in carefully selected cases.

  17. Retained Capsule Endoscope.

    PubMed

    Aihole, Jayalaxmi S; Vishnumurthy, G S; Babu, M Narendra

    2016-11-15

    Capsule endoscopy was invented to visualize the entire small intestine in a non- invasive manner in adults. 1 y, 9 mo-old boy presented with generalized edema for last 3 months. His routine investigations, including the upper gastrointestinal endoscopy, colonoscopy, and contrast enhanced computed tomography scan (CECT) were normal. In view of clinical suspicion of protein losing enteropathy, we planned capsule endoscopy. The capsule was not passed even after 3 weeks. Laparoscopy revealed impacted capsule in a dilated intestinal loop proximal to an ileal stricuture. Capsule endoscopy should be used judiciously in children.

  18. Process Development and Micro-Machining of MARBLE Foam-Cored Rexolite Hemi-Shell Ablator Capsules

    DOE PAGES

    Randolph, Randall Blaine; Oertel, John A.; Schmidt, Derek William; ...

    2016-06-30

    For this study, machined CH hemi-shell ablator capsules have been successfully produced by the MST-7 Target Fabrication Team at Los Alamos National Laboratory. Process development and micro-machining techniques have been developed to produce capsules for both the Omega and National Ignition Facility (NIF) campaigns. These capsules are gas filled up to 10 atm and consist of a machined plastic hemi-shell outer layer that accommodates various specially engineered low-density polystyrene foam cores. Machining and assembly of the two-part, step-jointed plastic hemi-shell outer layer required development of new techniques, processes, and tooling while still meeting very aggressive shot schedules for both campaigns.more » Finally, problems encountered and process improvements will be discussed that describe this very unique, complex capsule design approach through the first Omega proof-of-concept version to the larger NIF version.« less

  19. Modular "plug-and-play" capsules for multi-capsule environment in the gastrointestinal tract.

    PubMed

    Phee, S J; Ting, E K; Lin, L; Huynh, V A; Kencana, A P; Wong, K J; Tan, S L

    2009-01-01

    The invention of wireless capsule endoscopy has opened new ways of diagnosing and treating diseases in the gastrointestinal tract. Current wireless capsules can perform simple operations such as imaging and data collection (like temperature, pressure, and pH) in the gastrointestinal tract. Researchers are now focusing on adding more sophisticated functions such as drug delivery, surgical clips/tags deployment, and tissue samples collection. The finite on-board power on these capsules is one of the factors that limits the functionalities of these wireless capsules. Thus multiple application-specific capsules would be needed to complete an endoscopic operation. This would give rise to a multi-capsule environment. Having a modular "plug-and-play" capsule design would facilitate doctors in configuring multiple application-specific capsules, e.g. tagging capsule, for use in the gastrointestinal tract. This multi-capsule environment also has the advantage of reducing power consumption through asymmetric multi-hop communication.

  20. Indian Hedgehog signaling pathway members are associated with magnetic resonance imaging manifestations and pathological scores in lumbar facet joint osteoarthritis

    NASA Astrophysics Data System (ADS)

    Shuang, Feng; Zhou, Ying; Hou, Shu-Xun; Zhu, Jia-Liang; Liu, Yan; Zhang, Chun-Li; Tang, Jia-Guang

    2015-05-01

    Indian Hedgehog (HH) has been shown to be involved in osteoarthritis (OA) in articular joints, where there is evidence that Indian HH blockade could ameliorate OA. It seems to play a prominent role in development of the intervertebral disc (IVD) and in postnatal maintenance. There is little work on IHH in the IVD. Hence the aim of the current study was to investigate the role of Indian Hedgehog in the pathology of facet joint (FJ) OA. 24 patients diagnosed with lumbar intervertebral disk herniation or degenerative spinal stenosis were included. Preoperative magnetic resonance imaging (MRI) and Osteoarthritis Research Society International (OARSI) histopathology grading system was correlated to the mRNA levels of GLI1, PTCH1, and HHIP in the FJs. The Weishaupt grading and OARSI scores showed high positive correlation (r = 0.894) (P < 0.01). MRI Weishaupt grades showed positive correlation with GLI1 (r = 0.491), PTCH1 (r = 0.444), and HHIP (r = 0.654) mRNA levels (P < 0.05 in each case). OARSI scores were also positively correlated with GLI1 (r = 0. 646), PTCH1 (r = 0. 518), and HHIP (r = 0.762) mRNA levels (P < 0.01 in each case). Cumulatively our findings indicate that Indian HH signaling is increased in OA and is perhaps a key component in OA pathogenesis and progression.

  1. Innervation of the wrist joint and surgical perspectives of denervation.

    PubMed

    Van de Pol, Gerrit J; Koudstaal, Maarten J; Schuurman, Arnold H; Bleys, Ronald L A W

    2006-01-01

    Because our experience with the techniques used in denervation surgery of the wrist joint often has proven insufficient in treating chronic pain we conducted an anatomic study to clarify the exact contributions of the nerves supplying the wrist joint. Our goal was to reveal all periosteal and capsular nerve connections and if necessary adjust our technique used in denervation surgery. Innervation of the wrist joint was investigated by microdissection and histologic examination of 18 human wrists. An acetylcholinesterase method was used to identify the nerves, both in whole-mount preparations and in sections. We found that the main innervation to the wrist capsule and periosteal nerve network came from the anterior interosseous nerve, lateral antebrachial cutaneous nerve, and posterior interosseous nerve. The palmar cutaneous branch of the median nerve, the deep branch of the ulnar nerve, the superficial branch of the radial nerve, and the dorsal branch of the ulnar nerve also were found to have connections with the capsule. The periosteal nerve branches did not appear to play a major role in the innervation of the capsule and ligaments; here the specific articular nerve branches proved more important. The posterior and medial antebrachial cutaneous nerves did not connect to the wrist capsule or periosteum but rather terminated in the extensor and flexor retinaculum. Based on our findings we propose to denervate the wrist by making 2 incisions. With one palmar and one dorsal incision it should be possible to disconnect the periosteum from the capsule and interrupt the majority of the capsular nerve branches.

  2. Effects of Facet Joint Injection Reducing the Need for Percutaneous Vertebroplasty in Vertebral Compression Fractures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Im, Tae Seong; Lee, Joon Woo; Lee, Eugene

    ObjectiveTo evaluate the effects of facet joint injection (FJI) reducing the need for percutaneous vertebroplasty (PVP) in cases of vertebral compression fracture (VCF).Materials and MethodsA total of 169 patients who were referred to the radiology department of our institution for PVP between January 2011 and December 2014 were retrospectively evaluated. The effectiveness of FJI was evaluated by the proportion of patients who cancelled PVP and who experienced reduced pain. In addition, by means of medical chart and MRI review, those clinical factors (age, sex, history of trauma, amount of injected steroids and interval days elapsed between VCF and FJI) andmore » MR image factors (kyphosis angle, height loss, single or multiple level of VCF, burst fracture, central canal compromise, posterior element injury) that were believed to be significant for the effectiveness of FJI were statistically analysed.ResultsIn the 26 patients with FJI prior to PVP, six (23 %) patients cancelled PVP with considerable improvement in reported pain. In the 20 patients with PVP after FJI, improvement in pain after FJI was reported by six patients, resulting in a total of 12 patients (46 %) who experienced reduced pain after FJI. Clinical factors and MR image factors did not show any statistically significant difference between those groups, divided by PVP cancellation and by improvement of pain.ConclusionAfter FJI prior to PVP, about one quarter of patients cancelled PVP due to reduced pain and overall about half of the patients experienced reduced pain.« less

  3. [Temporo-mandibular joint. Morpho-functional considerations].

    PubMed

    Scutariu, M D; Indrei, Anca

    2004-01-01

    The temporo-mandibular joint is distinguished from most other synovial joints of the body by two features: 1. the two jointed components carry teeth whose position and occlusion introduce a very strong influence on the movements of the temporo-mandibular joint and 2. its articular surfaces are not covered by hyaline cartilage, but by a dense, fibrous tissue. This paper describes the parts of the temporo-mandibular joint: the articular surfaces (the condylar process of the mandible and the glenoid part of the temporal bone), the fibrocartilaginous disc which is interposed between the mandibular and the temporal surface, the fibrous capsule of the temporo-mandibular joint and the ligaments of this joint. All these parts present a very strong adaptation at the important functions of the temporo-mandibular joint.

  4. Maintenance of arytenoid abduction following carbon dioxide laser debridement of the articular cartilage and joint capsule of the cricoarytenoid joint combined with prosthetic laryngoplasty in horses: an in vivo and in vitro study.

    PubMed

    Hawkins, J F; Couetil, L; Miller, M A

    2014-02-01

    The objective was to evaluate CO2 laser debridement of the cricoarytenoid joint (CAJ) combined with prosthetic laryngoplasty to prevent post-operative loss of arytenoid abduction in seven horses. Horses were assigned to either laser debridement of the left CAJ and laryngoplasty (laser treated, n=5) or control laryngoplasty (sham, n=2), and were evaluated with endoscopic examinations and measurement of right to left angle quotients (RLQ) to assess maintenance of arytenoid abduction. The animals were euthanased at intervals after surgery and larynges were harvested for post-mortem testing, including determination of translaryngeal flow, pressure, impedance and RLQ. Measurements were obtained under increasing vacuum-generated negative pressure with laryngoplasty sutures intact and with the knot/crimp of the laryngoplasty sutures removed. Following post-mortem testing the cricoarytenoid joints were examined histologically. Post-operative endoscopic examinations revealed no significant differences between RLQ measurements calculated for day 1 following surgery to the termination date of the study for the seven horses. Post-mortem RLQ at airflows of 10 and 60 L/s was significantly higher in sham than in laser treated horses both before and after knot/crimp removal. Translaryngeal impedance at 10 and 60 L/s was not statistically different between groups. Histopathology revealed necrosis and loss of articular cartilage in the laser treated horses. The lymphoid cell infiltration subsided but joint capsule and periarticular fibrosis increased over the course of the study. Post-operative loss of arytenoid abduction after laryngoplasty can be minimized with CO2 laser debridement of the CAJ joint. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. Kinematic and fatigue biomechanics of an interpositional facet arthroplasty device.

    PubMed

    Dahl, Michael C; Freeman, Andrew L

    2016-04-01

    Although approximately 30% of chronic lumbar pain can be attributed to the facets, limited surgical options exist for patients. Interpositional facet arthroplasty (IFA) is a novel treatment for lumbar facetogenic pain designed to provide patients who gain insufficient relief from medical interventional treatment options with long-term relief, filling a void in the facet pain treatment continuum. This study aimed to quantify the effect of IFA on segmental range of motion (ROM) compared with the intact state, and to observe device position and condition after 10,000 cycles of worst-case loading. In situ biomechanical analysis of the lumbar spine following implantation of a novel IFA device was carried out. Twelve cadaveric functional spinal units (L2-L3 and L5-S1) were tested in 7.5 Nm flexion-extension, lateral bending, and torsion while intact and following device implantation. Additionally, specimens underwent 10,000 cycles of worst-case complex loading and were testing in ROM again. Load-displacement and fluoroscopic data were analyzed to determine ROM and to evaluate device position during cyclic testing. Devices and facets were evaluated post testing. Institutional support for implant evaluation was received by Zyga Technology. Range of motion post implantation decreased versus intact, and then was restored post cyclic-testing. Of the tested devices, 6.5% displayed slight movement (0.5-2 mm), all from tight L2-L3 facet joints with misplaced devices or insufficient cartilage. No damage was observed on the devices, and wear patterns were primarily linear. The results from this in situ cadaveric biomechanics and cyclic fatigue study demonstrate that a low-profile, conformable IFA device can maintain position and facet functionality post implantation and through 10,000 complex loading cycles. In vivo conditions were not accounted for in this model, which may affect implant behavior not predictable via a biomechanical study. However, these data along with

  6. Facetal distraction as treatment for single- and multilevel cervical spondylotic radiculopathy and myelopathy: a preliminary report.

    PubMed

    Goel, Atul; Shah, Abhidha

    2011-06-01

    The authors discuss their successful preliminary experience with 36 cases of cervical spondylotic disease by performing facetal distraction using specially designed Goel cervical facet spacers. The clinical and radiological results of treatment are analyzed. The mechanism of action of the proposed spacers and the rationale for their use are evaluated. Between 2006 and February 2010, 36 patients were treated using the proposed technique. Of these patients, 18 had multilevel and 18 had single-level cervical spondylotic radiculopathy and/or myelopathy. The average follow-up period was 17 months with a minimum of 6 months. The Japanese Orthopaedic Association classification system, visual analog scale (neck pain and radiculopathy), and Odom criteria were used to monitor the clinical status of the patient. The patients were prospectively analyzed. The technique of surgery involved wide opening of the facet joints, denuding of articular cartilage, distraction of facets, and forced impaction of Goel cervical facet spacers into the articular cavity. Additionally, the interspinous process ligaments were resected, and corticocancellous bone graft from the iliac crest was placed and was stabilized over the adjoining laminae and facets after adequately preparing the host bone. Eighteen patients underwent single-level, 6 patients underwent 2-level, and 12 patients underwent 3-level treatment. The alterations in the physical architecture of spine and canal dimensions were evaluated before and after the placement of intrafacet joint spacers and after at least 6 months of follow-up. All patients had varying degrees of relief from symptoms of pain, radiculopathy, and myelopathy. Analysis of radiological features suggested that the distraction of facets with the spacers resulted in an increase in the intervertebral foraminal dimension (mean 2.2 mm), an increase in the height of the intervertebral disc space (range 0.4-1.2 mm), and an increase in the interspinous distance (mean 2

  7. PLIF Imaging of Capsule RCS Jets, Shear Layers, and Simulated Forebody Ablation

    NASA Technical Reports Server (NTRS)

    Inman, Jennifer A.; Danehy, Paul M.; Alderfer, David W.; Buck, Gregory M.; McCrea, Andrew

    2008-01-01

    Planar laser-induced fluorescence (PLIF) has been used to investigate hypersonic flows associated with capsule reentry vehicles. These flows included reaction control system (RCS) jets, shear layer flow, and simulated forebody heatshield ablation. Pitch, roll, and yaw RCS jets were studied. PLIF obtained planar slices in these flowfields. These slices could be viewed individually or they could be combined using computer visualization techniques to reconstruct the three dimensional shape of the flow. The tests described herein were conducted in the 31-Inch Mach 10 Air Tunnel at NASA Langley Research Center. Improvements to many facets of the imaging system increased the efficiency and quality of both data acquisition, in addition to increasing the overall robustness of the system.

  8. Posterior capsule opacification.

    PubMed

    Wormstone, I Michael; Wang, Lixin; Liu, Christopher S C

    2009-02-01

    Posterior Capsule Opacification (PCO) is the most common complication of cataract surgery. At present the only means of treating cataract is by surgical intervention, and this initially restores high visual quality. Unfortunately, PCO develops in a significant proportion of patients to such an extent that a secondary loss of vision occurs. A modern cataract operation generates a capsular bag, which comprises a proportion of the anterior and the entire posterior capsule. The bag remains in situ, partitions the aqueous and vitreous humours, and in the majority of cases, houses an intraocular lens. The production of a capsular bag following surgery permits a free passage of light along the visual axis through the transparent intraocular lens and thin acellular posterior capsule. However, on the remaining anterior capsule, lens epithelial cells stubbornly reside despite enduring the rigours of surgical trauma. This resilient group of cells then begin to re-colonise the denuded regions of the anterior capsule, encroach onto the intraocular lens surface, occupy regions of the outer anterior capsule and most importantly of all begin to colonise the previously cell-free posterior capsule. Cells continue to divide, begin to cover the posterior capsule and can ultimately encroach on the visual axis resulting in changes to the matrix and cell organization that can give rise to light scatter. This review will describe the biological mechanisms driving PCO progression and discuss the influence of IOL design, surgical techniques and putative drug therapies in regulating the rate and severity of PCO.

  9. Intra-articular calcaneal fractures: effect of open reduction and internal fixation on the contact characteristics of the subtalar joint.

    PubMed

    Mulcahy, D M; McCormack, D M; Stephens, M M

    1998-12-01

    Intra-articular calcaneal fractures are associated with significant long-term morbidity, and considerable controversy exists regarding the optimum method of treating them. The contact characteristics in the intact subtalar joint were determined at known loads and for different positions of the ankle and subtalar joint, using pressure-sensitive film (Super Low; Fuji, Itochu Canada Ltd, Montreal, Quebec). We measured the contact area to joint area ratio (pressure > 5 kg force/cm2 [kgf/cm2]) which normalizes for differences in joint size and the ratio of high pressure zone (>20 kgf/cm2) as a reflection of overall increase in joint pressure. Three simulated fracture patterns were then created and stabilized with either 1 or 2 mm of articular incongruity. Eight specimens were prepared with a primary fracture line through the posterior facet, eight with a joint depression-type fracture, and six with a central joint depression fracture. A measure of 1 to 2 mm of incongruity in the posterior facet for all three fracture patterns produced significant unloading of the depressed fragment, with a redistribution of the overall pattern of pressure distribution to parts of the facet that were previously unloaded.

  10. Retention of the capsule endoscope: a single-center experience of 1000 capsule endoscopy procedures.

    PubMed

    Li, Feng; Gurudu, Suryakanth R; De Petris, Giovanni; Sharma, Virender K; Shiff, Arthur D; Heigh, Russell I; Fleischer, David E; Post, Janice; Erickson, Paula; Leighton, Jonathan A

    2008-07-01

    Retention of the video capsule is the most significant complication associated with capsule endoscopy (CE). There are limited data on incidence, risk factors, and outcomes of capsule retention. We aimed to determine the incidence of capsule retention and to investigate the causes and clinical outcomes of capsule retention. Single tertiary referral medical center. All patients who underwent CE for suspected small bowel disease from June 2002 to March 2006. Retrospective case series. Capsule retention occurred in 1.4% of our patients (14/1000). Eleven patients failed to pass the capsule because of nonsteroidal anti-inflammatory drug (NSAID) enteropathy (diaphragm disease). One patient had capsule retention from an obstructing carcinoid tumor. Metastatic ovarian cancer with invasion of the ileum was the cause of retention in another patient. One patient who did not have surgical removal of the capsule because of loss of follow-up had retention caused by a small-bowel tumor suspicious for carcinoid tumor on CT enterography. All patients remained "asymptomatic" from the retained capsules. Thirteen patients underwent elective partial small-bowel resection and capsule removal. No deaths were associated with these surgeries. Eleven patients recovered promptly, whereas 2 patients had mild postoperative ileus. Retrospective study. Retention of the capsule endoscope appears to be infrequent. The most common cause is diaphragm disease resulting from NSAIDs in this study population. In most cases, capsule retention is asymptomatic, and it usually leads to surgical removal, which appears safe and also identifies and treats the underlying small-bowel condition.

  11. Pain & resistance in patients with adhesive capsulitis during contrast material injection phase of MR arthrography.

    PubMed

    Yilmaz, Mehmet Halit; Kantarci, Fatih; Adaletli, Ibrahim; Ulus, Sila; Gulsen, Fatih; Ozer, Harun; Aktas, Ilknur; Akgun, Kenan; Kanberoglu, Kaya

    2007-04-01

    Adhesive capsulitis of the shoulder is a condition of unknown aetiology that results in the development of restricted active and passive glenohumeral motion. It has been reported that magnetic resonance (MR) imaging is useful in diagnosing adhesive capsulitis. We carried out this study to assess how pain and/or resistance during contrast material injection affects the diagnosis of adhesive capsulitis on magnetic resonance (MR) arthrography. The study included MR arthrography examinations of 21 patients with a diagnosis of adhesive capsulitis. The control group consisted of 20 patients who presented clinically with rotator cuff tear. The pain (visual analog scale, VAS), resistance to injection and the amount of contrast material that could be injected during injection phase of MR arthrography was assessed and compared between groups. The patients in adhesive capsulitis group (mean VAS score 66.5+/-25.5) experienced more pain when compared with the control group (mean VAS score 34.9+/-27.7, P<0.001). A statistically significant difference (P<0.001) in terms of the amount of the injected fluid (4.3+/-2.6 ml for adhesive capsulitis group, and 10.9+/-4.1 ml for control group) was seen into the joint cavity. Resistance to injection was significantly more (P<0.001) in patients with adhesive capsulitis when compared to control group. Experience of pain during injection, a decreased amount of contrast material injected and resistance to injection in patients during injection phase of MR arthrography may suggest adhesive capsulitis.

  12. The sacroiliac joint: anatomy, physiology and clinical significance.

    PubMed

    Forst, Stacy L; Wheeler, Michael T; Fortin, Joseph D; Vilensky, Joel A

    2006-01-01

    The sacroiliac joint (SIJ) is a putative source of low back pain. The objective of this article is to provide clinicians with a concise review of SIJ structure and function, diagnostic indicators of SIJ-mediated pain, and therapeutic considerations. The SIJ is a true diarthrodial joint with unique characteristics not typically found in other diarthrodial joints. The joint differs with others in that it has fibrocartilage in addition to hyaline cartilage, there is discontinuity of the posterior capsule, and articular surfaces have many ridges and depressions. The sacroiliac joint is well innervated. Histological analysis of the sacroiliac joint has verified the presence of nerve fibers within the joint capsule and adjoining ligaments. It has been variously described that the sacroiliac joint receives its innervation from the ventral rami of L4 and L5, the superior gluteal nerve, and the dorsal rami of L5, S1, and S2, or that it is almost exclusively derived from the sacral dorsal rami. Even though the sacroiliac joint is a known putative source of low back and lower extremity pain, there are few findings that are pathognomonic of sacroiliac joint pain. The controlled diagnostic blocks utilizing the International Association for the Study of Pain (IASP) criteria demonstrated the prevalence of pain of sacroiliac joint origin in 19% to 30% of the patients suspected to have sacroiliac joint pain. Conservative management includes manual medicine techniques, pelvic stabilization exercises to allow dynamic postural control, and muscle balancing of the trunk and lower extremities. Interventional treatments include sacroiliac joint, intra-articular joint injections, radiofrequency neurotomy, prolotherapy, cryotherapy, and surgical treatment. The evidence for intra-articular injections and radiofrequency neurotomy has been shown to be limited in managing sacroiliac joint pain.

  13. Height of a faceted macrostep for sticky steps in a step-faceting zone

    NASA Astrophysics Data System (ADS)

    Akutsu, Noriko

    2018-02-01

    The driving force dependence of the surface velocity and the average height of faceted merged steps, the terrace-surface slope, and the elementary step velocity are studied using the Monte Carlo method in the nonequilibrium steady state. The Monte Carlo study is based on a lattice model, the restricted solid-on-solid model with point-contact-type step-step attraction (p-RSOS model). The main focus of this paper is a change of the "kink density" on the vicinal surface. The temperature is selected to be in the step-faceting zone [N. Akutsu, AIP Adv. 6, 035301 (2016), 10.1063/1.4943400] where the vicinal surface is surrounded by the (001) terrace and the (111) faceted step at equilibrium. Long time simulations are performed at this temperature to obtain steady states for the different driving forces that influence the growth/recession of the surface. A Wulff figure of the p-RSOS model is produced through the anomalous surface tension calculated using the density-matrix renormalization group method. The characteristics of the faceted macrostep profile at equilibrium are classified with respect to the connectivity of the surface tension. This surface tension connectivity also leads to a faceting diagram, where the separated areas are, respectively, classified as a Gruber-Mullins-Pokrovsky-Talapov zone, step droplet zone, and step-faceting zone. Although the p-RSOS model is a simplified model, the model shows a wide variety of dynamics in the step-faceting zone. There are four characteristic driving forces: Δ μy,Δ μf,Δ μc o , and Δ μR . For the absolute value of the driving force, |Δ μ | is smaller than Max[ Δ μy,Δ μf] , the step attachment-detachments are inhibited, and the vicinal surface consists of (001) terraces and the (111) side surfaces of the faceted macrosteps. For Max[ Δ μy,Δ μf]<|Δ μ |<Δ μc o , the surface grows/recedes intermittently through the two-dimensional (2D) heterogeneous nucleation at the facet edge of the macrostep. For Δ

  14. Lumbar Facet Tropism: A Comprehensive Review.

    PubMed

    Alonso, Fernando; Kirkpatrick, Christina M; Jeong, William; Fisahn, Christian; Usman, Sameera; Rustagi, Tarush; Loukas, Marios; Chapman, Jens R; Oskouian, Rod J; Tubbs, R Shane

    2017-06-01

    Scattered reports exist in the medical literature regarding facet tropism. However, this finding has had mixed conclusions regarding its origin and impact on the normal spine. We performed a literature review of the anatomy, embryology, biomechanics, and pathology related to lumbar facet tropism. Facet tropism is most commonly found at L4-L5 vertebral segments and there is some evidence that this condition may lead to facet degenerative spondylolisthesis, intervertebral disc disease, and other degenerative conditions. Long-term analyses of patients are necessary to elucidate relationships between associated findings and facet tropism. In addition, a universally agreed definition that is more precise should be developed for future investigative studies. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Pediatric capsule endoscopy: review of the small bowel and patency capsules.

    PubMed

    Cohen, Stanley A; Ephrath, Hagit; Lewis, Jeffery D; Klevens, Alan; Bergwerk, Ari; Liu, Steven; Patel, Dinesh; Reed-Knight, Bonney; Stallworth, Angela; Wakhisi, Tamara; Gold, Benjamin D

    2012-03-01

    Because capsule endoscopy (CE) avoids ionizing radiation, deep sedation, and general anesthesia, CE may be valuable in pediatrics. We report a single pediatric center's experience with the use and safety of CE. In a retrospective review of consecutive CE studies, 284 CE studies were performed in 277 patients with a mean age of 15 (±3.7) years during a 5-year period. The youngest to swallow the capsule was 4.6 years old. Twenty capsules were placed. Overall, 245 (86%) patients underwent CE for suspected (184, 65%) or confirmed (61, 21%) Crohn disease (CD); 27 (9.5%) anemia or gastrointestinal bleeding; 6 (2%) polyposis; and 4 (1.4%) celiac disease. Positive findings were observed in 205 (72%) of the studies, with 152 (54%) having small bowel findings. Of these, 72 (47%) were diagnostic. Gastric (95, 33%) and colonic (31, 11%) abnormalities were also identified. Five CE studies (1.8%) resulted in retention of the capsule in nonsurgical patients. A patency capsule before CE in 23 patients allowed 19 CE to proceed with only 1 retained capsule. In 65 (21%) patients, the video capsule did not enter the colon before the video's end. Of these, 36 (65%) had significant findings, including 27 (49%) documenting small bowel (SB) CD. CE is useful to diagnose SB disease in children. Even in a study population with a high prevalence of confirmed and suspected CD, the risk of retention remains small. The patency capsule may lessen that risk. CE may identify gastric or colonic disease even when SB lesions are not present.

  16. Does increased femoral antetorsion predispose to cartilage lesions of the patellofemoral joint?

    PubMed

    Oppermann, Johannes; Bredow, Jan; Wissusek, Boris; Spies, Christian Karl; Boese, Christoph Kolja; Chang, Shi-Min; Eysel, Peer; Dargel, Jens

    2017-09-01

    The purpose of this study was to investigate whether there was a relationship between femoral neck antetorsion and the presence and pattern of osteoarthritis of the patellofemoral joint. It was hypothesized that an increased femoral neck antetorsion (1) correlates with osteoarthritic changes of the lateral facet of the patellofemoral joint and (2) correlates with an increased lateral trochlear height and a decreased sulcus angle. Seventy-eight formalin-embedded cadaveric lower extremities from thirty-nine subjects with a median age of 74 years (range 60-88) were used. Surrounding soft tissues of the lower limb were removed. The femoral neck antetorsion was measured and referenced to the transepicondylar axis and the posterior condylar line. The height of the medial and lateral facet of the trochlea and the sulcus angle was measured. The location and the degree of patellofemoral cartilage degeneration were recorded. A Pearson's correlation analysis was performed to correlate the femoral neck antetorsion with the measured knee parameters. No significant correlation could be found between the femoral antetorsion and cartilage degeneration of the lateral patellofemoral joint (n.s.), the height of the lateral trochlea (n.s.) and the sulcus angle (n.s.). This study could not document that the femoral neck antetorsion and subsequent internal rotation of the distal femur correlated with the degree of degeneration of the lateral facet of the patellofemoral joint. Clinically, femoral internal rotation may play a minor role in the development of lateral patellofemoral joint degeneration.

  17. Does superior-segment facet violation or laminectomy destabilize the adjacent level in lumbar transpedicular fixation? An in vitro human cadaveric assessment.

    PubMed

    Cardoso, Mario J; Dmitriev, Anton E; Helgeson, Melvin; Lehman, Ronald A; Kuklo, Timothy R; Rosner, Michael K

    2008-12-15

    This is an in vitro biomechanical study. The current investigation was performed to evaluate adjacent level kinematic change following unilateral and bilateral facet violation and laminectomy following 1-, 2-, and 3-level reconstruction. The incidence of superior-segment facet violation with lumbar transpedicular fixation has been reported as high as 35%; however, its contribution to biomechanical instability at the supradjacent level is unknown. In addition, superior-segment laminectomy has been implicated as a risk factor for the development of adjacent level disease. The authors assess the acute biomechanical effects of proximal facet violation and subsequent laminectomy in an instrumented posterior fusion model in 10 cadaveric specimens. Biomechanical testing was performed on 10 human cadaveric spines under axial rotation (AR), flexion-extension (FE), and lateral bending (LB) loading. After intact analysis, pedicle screws were inserted from L5-S1 and testing repeated with: (1) preserved L4-L5 facets, (2) unilateral facet breach, (3) bilateral breach, and (4) L5 laminectomy. Following biomechanical analysis, instrumentation was extended to L4, then L3 and biomechanical testing repeated. Full range of motion (ROM) at the proximal adjacent levels were recorded and normalized to intact (100%). Supradjacent level ROM was increased for all groups under all loading methods relative to intact (P < 0.05). However, AR testing revealed progressive instability at the adjacent level in groups 3 and 4, relative to group 1, following 1-, 2- and 3-level fixation (P < 0.05). During FE, supradjacent level ROM was significantly increased for group 4 specimens compared with group 1 after L5-S1 fixation (P < 0.05), and was greater than all other groups for L3-S1 constructs (P < 0.05). Interestingly, under lateral bending, facet joint destabilization did not change adjacent segment ROM. There were significant changes in proximal level ROM immediately after posterior stabilization

  18. Biocompatible Capsules and Methods of Making

    NASA Technical Reports Server (NTRS)

    Loftus, David J. (Inventor)

    2017-01-01

    Embodiments of the invention include capsules for containing medical implants and delivery systems for release of active biological substances into a host body. Delivery systems comprise a capsule comprising an interior enclosed by walls, and a source of active biological substances enclosed within the capsule interior, wherein the active biological substances are free to diffuse across the capsule walls. The capsule walls comprise a continuous mesh of biocompatible fibers and a seal region where two capsule walls overlap. The interior of the capsule is substantially isolated from the medium surrounding the capsule, except for diffusion of at least one species of molecule between the capsule interior and the ambient medium, and prevents cell migration into or out of the capsule. Methods for preparing and using the capsules and delivery systems are provided.

  19. Effects of food on a gastrically degraded drug: azithromycin fast-dissolving gelatin capsules and HPMC capsules.

    PubMed

    Curatolo, William; Liu, Ping; Johnson, Barbara A; Hausberger, Angela; Quan, Ernest; Vendola, Thomas; Vatsaraj, Neha; Foulds, George; Vincent, John; Chandra, Richa

    2011-07-01

    Commercial azithromycin gelatin capsules (Zithromax®) are known to be bioequivalent to commercial azithromycin tablets (Zithromax®) when dosed in the fasted state. These capsules exhibit a reduced bioavailability when dosed in the fed state, while tablets do not. This gelatin capsule negative food effect was previously proposed to be due to slow and/or delayed capsule disintegration in the fed stomach, resulting in extended exposure of the drug to gastric acid, leading to degradation to des-cladinose-azithromycin (DCA). Azithromycin gelatin capsules were formulated with "superdisintegrants" to provide fast-dissolving capsules, and HPMC capsule shells were substituted for gelatin capsule shells, in an effort to eliminate the food effect. Healthy volunteers were dosed with these dosage forms under fasted and fed conditions; pharmacokinetics were evaluated. DCA pharmacokinetics were also evaluated for the HPMC capsule subjects. In vitro disintegration of azithromycin HPMC capsules in media containing food was evaluated and compared with commercial tablets and commercial gelatin capsules. When the two fast-dissolving capsule formulations were dosed to fed subjects, the azithromycin AUC was 38.9% and 52.1% lower than after fasted-state dosing. When HPMC capsules were dosed to fed subjects, the azithromycin AUC was 65.5% lower than after fasted-state dosing. For HPMC capsules, the absolute fasting-state to fed-state decrease in azithromycin AUC (on a molar basis) was similar to the increase in DCA AUC. In vitro capsule disintegration studies revealed extended disintegration times for commercial azithromycin gelatin capsules and HPMC capsules in media containing the liquid foods milk and Ensure®. Interaction of azithromycin gelatin and HPMC capsules with food results in slowed disintegration in vitro and decreased bioavailability in vivo. Concurrent measurement of serum azithromycin and the acid-degradation product DCA demonstrates that the loss of azithromycin

  20. Atlantoaxial joint distraction for treatment of basilar invagination secondary to rheumatoid arthritis.

    PubMed

    Goel, A; Pareikh, S; Sharma, P

    2005-06-01

    We present our experience of treating two cases of rheumatoid arthritis involving the craniovertebral junction and having marked basilar invagination by an alternative treatment method. In both the cases, the facets were osteoporotic and were not suitable for screw implantation. The patients were 66 and 72 years of age and both patients were females. Both the patients presented with complaints of progressively increasing spastic quadriparesis. Surgery involved attempts to reduce the basilar invagination and restore the height of the 'collapsed' lateral mass by manual distraction of the facets of the atlas and axis and forced impaction of titanium spacers in the joint in addition to bone graft harvested from the iliac crest. The procedure also provided stabilization of the region. No other fixation procedure involving wires, screws, plate and rods was carried out simultaneously. Following surgery both the patients showed symptomatic improvement and partial restoration of craniovertebral alignments. Follow-up is of 2 and 24 months. Distraction of the facets of atlas and axis and impaction of metal implant and bone graft in the facet joint can assist in reduction of basilar invagination and fixation of the region in selected cases of rheumatoid arthritis involving the craniovertebral junction.

  1. Design of a lattice-based faceted classification system

    NASA Technical Reports Server (NTRS)

    Eichmann, David A.; Atkins, John

    1992-01-01

    We describe a software reuse architecture supporting component retrieval by facet classes. The facets are organized into a lattice of facet sets and facet n-tuples. The query mechanism supports precise retrieval and flexible browsing.

  2. [Meniscoids of the intervertebral joints].

    PubMed

    Kos, J; Hert, J; Sevcík, P

    2002-01-01

    A large amount of material was used to study the distribution, location and shape of meniscoids in intervertebral joints of the human spine, from the atlanto-occipital joint to the sacrum, in order to find out how many of intervertebral joints had mobile meniscoids. These might be regarded as possible causes of spinal blockade or other vertebrogenous complaints. The materials provided by the Department of Anatomy and Department of Forensic Medicine at the Faculty of Medicine of Charles University in Pilznen included 20 cadaverous spines from humans aged 20 to 80 years. Access to each joint was provided by dissection of the articular capsule from the lower articular processes of the vertebra situated above. In the orthograde view, all meniscoids were described in terms of shape, size, consistence and location. Their structure was ascertained by histological examination of cross sections stained with haematoxylin and eosin. Meniscoids varying in shape and size were found in all of the intervertebral joints. They were classified by their histological structure as synovial, fat and fibrous meniscoids. The first category was observed frequently, the last only rarely. A total of 29 mobile meniscoids were recorded, most of them in the lumbar spine. Most of the meniscoids present in the cervical spine were of synovial and less frequently of fat types. Meniscoids found in the thoracic spine were poorly developed synovial ones and those present in the lumbar spine were of all types and were also largest in size. The most conspicuous meniscoids were seen in the spines that showed degenerative changes in intervertebral joints. Large fat pads were found in atlanto-occipital and atlanto-axial joints. Mobile meniscoids, most of them present in the lumbar spine (6.4% of all joints.), were connected with the capsule by a thin pedicle and it was possible to move them over a half of the articular surface. Some inter-individual changes were also found; in some spines, the most

  3. Chromium content in the human hip joint tissues.

    PubMed

    Brodziak-Dopierała, Barbara; Kwapuliński, Jerzy; Sobczyk, Krzysztof; Wiechuła, Danuta

    2015-02-01

    Chromium has many important functions in the human body. For the osseous tissue, its role has not been clearly defined. This study was aimed at determining chromium content in hip joint tissues. A total of 91 hip joint samples were taken in this study, including 66 from females and 25 from males. The sample tissues were separated according to their anatomical parts. The chromium content was determined by the AAS method. The statistical analysis was performed with U Mann-Whitney's non-parametric test, P≤0.05. The overall chromium content in tissues of the hip joint in the study subjects was as follows: 5.73 µg/g in the articular cartilage, 5.33 µg/g in the cortical bone, 17.86 µg/g in the cancellous bone, 5.95 µg/g in the fragment of the cancellous bone from the intertrochanteric region, and 1.28 µg/g in the joint capsule. The chromium contents were observed in 2 group patients, it was 7.04 µg/g in people with osteoarthritis and 12.59 µg/g in people with fractures. The observed chromium content was highest in the cancellous bone and the lowest in the joint capsule. Chromium content was significantly different between the people with hip joint osteoarthritis and the people with femoral neck fractures. Copyright © 2015 The Editorial Board of Biomedical and Environmental Sciences. Published by China CDC. All rights reserved.

  4. Mercury Capsule Separation Tests

    NASA Image and Video Library

    1960-04-01

    Mercury capsule separation from Redstone booster in the Altitude Wind Tunnel (AWT): NASA Lewis conducted full-scale separation tests of the posigrade rockets that were fired after the Redstone rockets burned out. The researchers studied the effect of the posigrade rockets firing on the Redstone booster and retrograde package. This film shows the Mercury capsule being mounted to the Redstone missile model in the Altitude Wind Tunnel. The capsule's engines are fired and it horizontally separates from the Atlas. After firing the capsule swings from an overhead crane.

  5. “Soft that molds the hard:” Geometric morphometry of lateral atlantoaxial joints focusing on the role of cartilage in changing the contour of bony articular surfaces

    PubMed Central

    Prasad, Prashant Kumar; Salunke, Pravin; Sahni, Daisy; Kalra, Parveen

    2017-01-01

    Purpose: The existing literature on lateral atlantoaxial joints is predominantly on bony facets and is unable to explain various C1-2 motions observed. Geometric morphometry of facets would help us in understanding the role of cartilages in C1-2 biomechanics/kinematics. Objective: Anthropometric measurements (bone and cartilage) of the atlantoaxial joint and to assess the role of cartilages in joint biomechanics. Materials and Methods: The authors studied 10 cadaveric atlantoaxial lateral joints with the articular cartilage in situ and after removing it, using three-dimensional laser scanner. The data were compared using geometric morphometry with emphasis on surface contours of articulating surfaces. Results: The bony inferior articular facet of atlas is concave in both sagittal and coronal plane. The bony superior articular facet of axis is convex in sagittal plane and is concave (laterally) and convex medially in the coronal plane. The bony articulating surfaces were nonconcordant. The articular cartilages of both C1 and C2 are biconvex in both planes and are thicker than the concavities of bony articulating surfaces. Conclusion: The biconvex structure of cartilage converts the surface morphology of C1-C2 bony facets from concave on concavo-convex to convex on convex. This reduces the contact point making the six degrees of freedom of motion possible and also makes the joint gyroscopic. PMID:29403249

  6. Sweat collection capsule

    NASA Technical Reports Server (NTRS)

    Delaplaine, R. W.; Greenleaf, J. E.

    1979-01-01

    Capsule, with filter paper insert, is used to collect sweat for rate monitoring, chromatographic analysis, or active sweat gland location within specified area. Construction of capsule allows change of inserts while device remains strapped in place.

  7. Engineering fluorescent poly(dopamine) capsules.

    PubMed

    Chen, Xi; Yan, Yan; Müllner, Markus; van Koeverden, Martin P; Noi, Ka Fung; Zhu, Wei; Caruso, Frank

    2014-03-18

    The recent development of poly(dopamine) (PDA) capsules provides new opportunities for their application in biology and medicine. To advance the biomedical application of PDA capsules, strategies that enable the preparation of fluorescently labeled PDA (F-PDA) capsules are required, as this will allow evaluation of their cellular interactions using a range of fluorescence-based techniques. Herein, we report a facile approach for the fabrication of F-PDA capsules via the polymerization of dopamine (DA) on sacrificial templates in the presence of hydrogen peroxide (H2O2). F-PDA capsules with well-defined sizes are prepared by templating different organic and inorganic particles. The resulting F-PDA capsules show negligible cytotoxicity in HeLa cells after incubation for 48 h. We also demonstrate visualization of the F-PDA capsules following internalization by HeLa cells using conventional fluorescence microscopy, en route toward detailed investigations on their biological interactions.

  8. FACET: Future ATM Concepts Evaluation Tool

    NASA Technical Reports Server (NTRS)

    Bilmoria, Karl D.; Banavar, Sridhar; Chatterji, Gano B.; Sheth, Kapil S.; Grabbe, Shon

    2000-01-01

    FACET (Future ATM Concepts Evaluation Tool) is an Air Traffic Management research tool being developed at the NASA Ames Research Center. This paper describes the design, architecture and functionalities of FACET. The purpose of FACET is to provide E simulation environment for exploration, development and evaluation of advanced ATM concepts. Examples of these concepts include new ATM paradigms such as Distributed Air-Ground Traffic Management, airspace redesign and new Decision Support Tools (DSTs) for controllers working within the operational procedures of the existing air traffic control system. FACET is currently capable of modeling system-wide en route airspace operations over the contiguous United States. Airspace models (e.g., Center/sector boundaries, airways, locations of navigation aids and airports) are available from databases. A core capability of FACET is the modeling of aircraft trajectories. Using round-earth kinematic equations, aircraft can be flown along flight plan routes or great circle routes as they climb, cruise and descend according to their individual aircraft-type performance models. Performance parameters (e.g., climb/descent rates and speeds, cruise speeds) are obtained from data table lookups. Heading, airspeed and altitude-rate dynamics are also modeled. Additional functionalities will be added as necessary for specific applications. FACET software is written in Java and C programming languages. It is platform-independent, and can be run on a variety of computers. FACET has been designed with a modular software architecture to enable rapid integration of research prototype implementations of new ATM concepts. There are several advanced ATM concepts that are currently being implemented in FACET airborne separation assurance, dynamic density predictions, airspace redesign (re-sectorization), benefits of a controller DST for direct-routing, and the integration of commercial space transportation system operations into the U.S. National

  9. The effect of intra-articular hyaluronate and tramadol injection on patients with adhesive capsulitis of the shoulder.

    PubMed

    Kim, Kyung-Hee; Suh, Jung-Woo; Oh, Ki Young

    2017-08-03

    Local administration of opioids causes effective analgesia without adverse effects related to the central nervous system. After the beneficial demonstration of peripheral opioid receptors in joint synovia, intra-articular opioid injections were used for pain treatment. Clinical studies have reported the safety and efficacy of hyaluronate injection in the shoulder joint of patients with osteoarthritis, periarthritis, rotator cuff tears, and adhesive capsulitis. To estimate the efficacy of intra-articular hyaluronate and tramadol injection for adhesive capsulitis of the shoulder compared with that of intra-articular hyaluronate injection alone. Thirty patients with adhesive capsulitis of the shoulder were randomized to the hyaluronate group (n= 16) or the tramadol group (n= 14). Hyaluronate group members were administered five weekly intra-articular hyaluronate injections; tramadol group members were administered three weekly intra-articular hyaluronate and tramadol injections and then two weekly intra-articular injections of hyaluronate. Visual Analog Scale (VAS), passive range of motion (PROM) of the shoulder joint, and Shoulder Pain and Disability Index (SPADI) scores were assessed at baseline and weeks 1, 2, 3, 4, and 6 after the initial injection. A significant improvement was observed in VAS, PROM, and SPADI scores between time points in both groups. In comparison in both groups at weeks 1 and 2 after the initial injection the VAS scores of the tramadol group were significantly lower than those of the hyaluronate group. Intra-articular hyaluronate with tramadol showed more rapid and strong analgesic effects than intra-articular hyaluronate alone and did not induce any adverse effects.

  10. The Lens Capsule

    PubMed Central

    Danysh, Brian P.; Duncan, Melinda K.

    2009-01-01

    The lens capsule is a modified basement membrane that completely surrounds the ocular lens. It is known that this extracellular matrix is important for both the structure and biomechanics of the lens in addition to providing informational cues to maintain lens cell phenotype. This review covers the development and structure of the lens capsule, lens diseases associated with mutations in extracellular matrix genes and the role of the capsule in lens function including those proposed for visual accommodation, selective permeability to infectious agents, and cell signaling. PMID:18773892

  11. Magneto-responsive alginate capsules.

    PubMed

    Degen, Patrick; Zwar, Elena; Schulz, Imke; Rehage, Heinz

    2015-05-20

    Upon incorporation of magnetic nanoparticles (mNPs) into gels, composite materials called ferrogels are obtained. These magneto-responsive systems have a wide range of potential applications including switches and sensors as well as drug delivery systems. In this article, we focus on the properties of calcium alginate capsules, which are widely used as carrier systems in medicine and technology. We studied the incorporation of different kinds of mNPs in matrix capsules and in the core and the shell of hollow particles. We found out that not all particle-alginate or particle-CaCl2 solution combinations were suitable for a successful capsule preparation on grounds of a destabilization of the nanoparticles or the polymer. For those systems allowing the preparation of switchable beads or capsules, we systematically studied the size and microscopic structure of the capsules, their magnetic behavior and mechanical resistance.

  12. Oxygen Fugacity in Large Metal Capsules

    NASA Astrophysics Data System (ADS)

    Faul, U.; Cline, C. J., II; Jackson, I.; Berry, A.

    2016-12-01

    During experiments with iron bearing silicates, equilibration between metal capsules and sample interior depends on diffusion of Fe if the capsule composition is not initially in equilibrium with the sample composition. For example, placing Pt or Ni capsules in contact with Fe-bearing olivine leads to Fe-loss from the olivine. In a fully equilibrated system the Fe contents of coexisting metal capsule and olivine reflect the oxygen fugacity (fO2) of the system. Experiments were conducted with olivine encapsulated or wrapped in four different metals (Fe, Ni70Fe30, Ni and Pt) to determine the fO2 in the cm-sized samples used for deformation and seismic property experiments. Small Pt particles mixed with olivine powder were used as fO2 sensors in the interior of the capsules. The results show an ordering of the fO2 in the interior that is consistent with the enclosing metals, i.e. the fO2 is lowest in a Fe capsule and highest in a Pt capsule. However, fO2 values in the more oxidizing metal capsules are substantially below their respective metal-oxide buffers. For example, solgel olivine encapsulated in Ni has an oxygen fugacity that is more than three orders of magnitude below Ni-NiO at 1200C and 0.3 GPa. The fO2 in a capsule interior is therefore to some extent self-buffering and only moderately influenced by the composition of the capsule. While the Pt particles in the interior are equilibrated, Fe gradients from the interior up to the Pt and Ni sample-capsule interfaces show that Fe loss into the capsules is diffusion limited. The fO2 at the interface also has implications for the water retention in unbuffered capsules. We infer that relatively high fO2 and hence fH2O observed adjacent to Pt capsules enables retention of water in these capsules, but the fO2 adjacent to Ni capsules is too low and water is lost.

  13. The development of pyro shock test requirements for Viking Lander Capsule components

    NASA Technical Reports Server (NTRS)

    Barrett, S.

    1975-01-01

    The procedure used to derive component-level pyro shock specifications for the Viking Lander Capsule (VLC) is described. Effects of shock path distance and mechanical joints between the device and the point at which the environment is to be estimated are accounted for in the method. The validity of the prediction technique was verified by a series of shock tests on a full-scale structural model of the lander body.

  14. Ablating spinal NK1-bearing neurons eliminates the development of pain & reduces spinal neuronal hyperexcitability & inflammation from mechanical joint injury in the rat

    PubMed Central

    Weisshaar, Christine L.; Winkelstein, Beth A.

    2014-01-01

    The facet joint is a common source of pain especially from mechanical injury. Although chronic pain is associated with altered spinal glial and neuronal responses, the contribution of specific spinal cells to joint pain are not understood. This study used the neurotoxin [Sar9,Met(O2)11]-substance P-saporin (SSP-SAP) to selectively eliminate spinal cells expressing neurokinin-1 receptor (NK1R) in a rat model of painful facet joint injury to determine the role of those spinal neurons in pain from facet injury. Following spinal administration of SSP-SAP or its control (blank-SAP), a cervical facet injury was imposed and behavioral sensitivity assessed. Spinal extracellular recordings were made on day 7 to classify neurons and quantify evoked firing. Spinal glial activation and IL1α expression also were evaluated. SSP-SAP prevented the development of mechanical hyperalgesia that is induced by joint injury and reduced NK1R expression and mechanically-evoked neuronal firing in the dorsal horn. SSP-SAP also prevented a shift toward wide dynamic range neurons that is seen after injury. Spinal astrocytic activation and IL1α expression were reduced to sham levels with SSP-SAP treatment. These results suggest that spinal NK1R-bearing cells are critical in initiating spinal nociception and inflammation associated with a painful mechanical joint injury. Perspective Results demonstrate that cells expressing NK1R in the spinal cord are critical for the development of joint pain and spinal neuroplasticity and inflammation after trauma to the joint. These findings have utility for understanding mechanisms of joint pain and developing potential targets to treat pain. PMID:24389017

  15. Distal radius fractures and the volar lunate facet fragment: Kirschner wire fixation in addition to volar-locked plating.

    PubMed

    Moore, Amy M; Dennison, David G

    2014-06-01

    The volar lunate facet fragment of a distal radius fracture may not be stabilized with volar-locked plating alone due to the small size and distal location of the fragment. Identification and stabilization of this small fragment is critical as unstable fixation may result in radiocarpal and radioulnar joint subluxation. The addition of spring wire fixation with volar plating can provide stable internal fixation of this critical fracture fragment. A retrospective review (2006-2011) identified nine patients with distal radius fractures with an associated volar lunate facet fragment that were treated with volar-locked plating and spring wire fixation of the volar lunate facet fragment. Radiographic indices, range of motion, grip strength, and postoperative Patient-related wrist evaluation (PRWE) scores were obtained to assess pain and function. All distal radius fractures healed, and the volar lunate facet fragment reduction was maintained. The mean follow-up was 54 weeks. Mean active range of motion was 46° wrist flexion, 51° wrist extension, 80° pronation, and 68° supination. The mean grip strength was 21 Kg, achieving 66 % of the uninjured limb. The average PRWE score was 17. No patient required removal of hardware or had evidence of tendon irritation. The addition of spring wire fixation to volar-locked plating provided stable fixation of the volar lunate facet fragment of distal radius fractures without complication. This technique addresses a limitation of volar-locked plating to control the small volar lunate facet fragment in distal radius fractures otherwise amenable to volar plating. A retrospective case series, Level IV.

  16. Polydopamine-coated capsules

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    White, Scott R.; Sottos, Nancy R.; Kang, Sen

    One aspect of the invention is a polymer material comprising a capsule coated with PDA. In certain embodiments, the capsule encapsulates a functional agent. The encapsulated functional agent may be an indicating agent, healing agent, protecting agent, pharmaceutical drug, food additive, or a combination thereof.

  17. Endoplasmic reticulum stress-dependent ROS production mediates synovial myofibroblastic differentiation in the immobilization-induced rat knee joint contracture model.

    PubMed

    Jiang, Shihai; He, Ronghan; Zhu, Lei; Liang, Tangzhao; Wang, Zhe; Lu, Yunxiang; Ren, Jianhua; Yi, Xiaoyou; Xiao, Dahai; Wang, Kun

    2018-05-30

    Joint contracture is a common complication for people with joint immobility that involves fibrosis structural alteration in the joint capsule. Considering that endoplasmic reticulum (ER) stress plays a prominent role in the promotion of tissue fibrosis, we investigated whether the unfolded protein response (UPR) contributes to the fibrotic development in immobilization-induced knee joint contractures. Using a non-traumatic rat knee joint contracture model, twelve female Sprague-Dawley rats received knee joint immobilization for a period of 8 weeks. We found that fibrosis protein markers (type I collagen, α-SMA) and UPR (GRP78, ATF6α, XBP1s) markers were parallelly upregulated in rat primary cultured synovial myofibroblasts. In the same cell types, pre-treatment with an ER stress inhibitor, 4-phenylbutyric acid (4-PBA), not only abrogated cytokine TGFβ1 stimulation but also reduced the protein level of UPR. Additionally, high reactive oxygen species (ROS) generation was detected in synovial myofibroblasts through flow cytometry, as expected. Notably, TGFβ1-induced UPR was significantly reduced through the inhibition of ROS with antioxidants. These data suggest that ER stress act as a pro-fibrotic stimulus through the overexpression of ROS in synovial fibroblasts. Interestingly, immunohistochemical results showed an increase in the UPR protein levels both in human acquired joint contractures capsule tissue and in animal knee joint contracture tissue. Together, our findings suggest that ER stress contributes to synovial myofibroblastic differentiation in joint capsule fibrosis and may also serve as a potential therapeutic target in joint contractures. Copyright © 2018 Elsevier Inc. All rights reserved.

  18. Ganglion cyst of the temporomandibular joint.

    PubMed

    Heng-Kun, W; Yan-Ling, G; Wen-Feng, Z; Zhe, S; Ren-Xin, W; Xiao-Tao, Z

    2014-02-01

    Ganglion cyst of the temporomandibular joint is a rare disease, which may arise from myxoid degeneration of the collagenous tissue of the temporomandibular joint capsule, without epithelial or endothelial lining. We report a case of cystic lesion in a 40-year-old female patient. The patient had a left pre-auricular oval-shaped swelling without any articular symptoms. The pathological analysis after surgical removal allowed diagnosing the lesion as a ganglion cyst of the left temporomandibular joint. We made a literature review and noted that this condition was predominant in female patients. We recommend using MRI for diagnostic purposes and surgery as the best therapeutic alternative. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  19. Determination of Parachute Joint Factors using Seam and Joint Testing

    NASA Technical Reports Server (NTRS)

    Mollmann, Catherine

    2015-01-01

    This paper details the methodology for determining the joint factor for all parachute components. This method has been successfully implemented on the Capsule Parachute Assembly System (CPAS) for the NASA Orion crew module for use in determining the margin of safety for each component under peak loads. Also discussed are concepts behind the joint factor and what drives the loss of material strength at joints. The joint factor is defined as a "loss in joint strength...relative to the basic material strength" that occurs when "textiles are connected to each other or to metals." During the CPAS engineering development phase, a conservative joint factor of 0.80 was assumed for each parachute component. In order to refine this factor and eliminate excess conservatism, a seam and joint testing program was implemented as part of the structural validation. This method split each of the parachute structural joints into discrete tensile tests designed to duplicate the loading of each joint. Breaking strength data collected from destructive pull testing was then used to calculate the joint factor in the form of an efficiency. Joint efficiency is the percentage of the base material strength that remains after degradation due to sewing or interaction with other components; it is used interchangeably with joint factor in this paper. Parachute materials vary in type-mainly cord, tape, webbing, and cloth -which require different test fixtures and joint sample construction methods. This paper defines guidelines for designing and testing samples based on materials and test goals. Using the test methodology and analysis approach detailed in this paper, the minimum joint factor for each parachute component can be formulated. The joint factors can then be used to calculate the design factor and margin of safety for that component, a critical part of the design verification process.

  20. Antero-medial approach to the wrist: anatomic basis and new application in cases of fracture of the lunate facet.

    PubMed

    Uzel, A-P; Bulla, A; Laurent-Joye, M; Caix, P

    2011-08-01

    The Henry approach is the classical anterolateral surgical exposure of the volar aspect of the distal radius. This approach does not allow good access to the medial side of the volar distal radius (lunate facet) and the distal radio-ulnar joint, unless it is extended proximally, retracting the tendons and the median nerve medially, which can cause some trauma. The purpose of our study was to investigate the anatomic basis and to outline the advantages of the unusual anteromedial approach, reporting our experience in the treatment of 4 distal radius fractures, with a 90° or 180° twist of the lunate facet, and 10 wrist dissections on cadavers. The average follow-up was 68.8 months (range 18 to 115 months). In our series, this approach did not cause any nerve injuries or any sensory loss of the distal forearm and the palm. All the fractures of the lunate facet and of the radial styloid process healed. One patient with an ulnar styloid process fracture associated showed pseudarthrosis, but with no instability of the distal radio-ulnar joint or pain on the ulnar side. Using the criteria of Green and O'Brien, modified by Cooney, the results were: excellent in two cases, good in one case, and average in another. The evaluation of arthritis according to Knirk and Jupiter's classification showed grade 0 in three cases and grade 3 in one case with osteochondral sclerosis. We showed that the anteromedial approach is reliable and convenient in the case of fractures situated in the antero-medial portion of the radius, for the double objective of reducing the fracture under direct control and checking the congruence of the distal radio-ulnar joint.

  1. [Effects of exercise on joints.

    PubMed

    Moriyama, Hideki

    Joints are composed of several different tissues(cartilage, capsule, meniscus, and ligament), and articular cartilage plays an important role in maintaining mechanical competence during exercise. Weight-bearing exercise has several benefit, including improved blood and synovial fluid circulation in a given joint. Consistent moderate activities facilitate cycles of anabolism and catabolism. Mechanical stresses are crucial for the maintenance of the morphologic and functional integrity of articular cartilage. Healthy cartilage is exposed by hydrostatic pressure and tensile strain, when cartilage degeneration develops, abnormal cartilage is exposed by shear stress. Moderate(physiological)exercise is characterized by a range of equilibrium between matrix anabolic and catabolic processes, or anabolism beyond catabolism. Joints are susceptible to insufficient or excessive activities, leading to joint degeneration. Lack of exercise is known to induce joint contracture seen clinically as a consequence of disuse changes, and excess mechanical stresses induce joint destruction such as osteoarthritis. Joint diseases resulting from insufficient or excessive activities are new and major challenging issues with our aging population. Thus, it is highly desirable to have an effective and efficient treatment to improve and protect against these joint diseases, and thereby to solve these clearly unanswered issues.

  2. The Many Facets of PISA

    ERIC Educational Resources Information Center

    Berliner, David C.

    2015-01-01

    Trying to understand PISA is analogous to the parable of the blind men and the elephant. There are many facets of the PISA program, and thus many ways to both applaud and critique this ambitious international program of assessment that has gained enormous importance in the crafting of contemporary educational policy. One of the facets discussed in…

  3. Effect of rotator cuff strengthening as an adjunct to standard care in subjects with adhesive capsulitis: A randomized controlled trial.

    PubMed

    Rawat, Pallavi; Eapen, Charu; Seema, Kulathuran Pillai

    Randomized controlled trial. To study the effect of adding rotator cuff (RC) muscles strengthening to joint mobilization and transcutaneous electrical nerve stimulation (TENS) in patients with adhesive capsulitis. A prospective, parallel-group, randomised clinical trial was conducted on 42 patients. One group received TENS and joint mobilization and in the other group RC muscles strengthening was added. Treatment was given for 12 sessions within 4 weeks. When compared between the groups statistically significant changes were seen in all the outcome measures in the group that received RC muscle strengthening exercises vs TENS and mobilization. VAS 12.76 ± 1.04 vs 4.05 ± 1.32; SPADI 34.66 ± 6.69 vs 54.29 ± 12.17; PFPS 3.06 ± 0.80 vs 4.70 ± 0.81; and ROM (elevation >125 vs >110 degrees and rotations >70 vs >48 degrees). Addition of a structured RC strengthening program to TENS and joint mobilization in the treatment of adhesive capsulitis resulted in improvement in pain, ROM and function. 1b. Copyright © 2016 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  4. Ethical aspects of capsule endoscopy.

    PubMed

    Niv, Yaron

    2008-01-01

    Capsule endoscopy is the most recent innovation in gastrointestinal endoscopy. The capsule contains a video camera that photographs the bowel for 8 h after the capsule has been orally ingested and transmits the images for interpretation to a computerized workstation. Ethical considerations of the use of capsule endoscopy should cover the following main issues: justification of the procedure, its potential benefits and harm, and patient autonomy. Capsule endoscopy has several advantages over traditional endoscopy. The procedure is painless, does not require sedation, is easy to perform and for the first time enables exploration of the entire small bowel at high magnification. However, the clinician cannot control its passive advance along the bowel. In addition, the examination may be incomplete, as the capsule reaches the cecum in only 80% of cases. This paper discusses the problems related to the new endoscopic procedure, the diagnostic yield in comparison with other procedures, proper indications for the procedure, outcome and complications. Copyright 2008 S. Karger AG, Basel.

  5. Polyelectrolyte capsules preloaded with interconnected alginate matrix: An effective capsule system for encapsulation and release of macromolecules.

    PubMed

    Sundaramurthy, Anandhakumar; Sundramoorthy, Ashok K

    2018-02-01

    In recent years, the design of stimuli-responsive hollow polymeric capsules is of tremendous interest for the scientific community because of the broad application of these capsules in the biomedical field. The use of weak polyelectrolytes as layer components for capsule fabrication is especially interesting as it results in hollow capsules that show unique release characteristics under physiological conditions. In this work, a methodology to prepare sub-micron sized alginate doped calcium carbonate (CaCO 3 ) particles through controlled precipitation in the presence of alginate is reported. Hollow capsules obtained by Layer-by-Layer (LbL) assembly of poly(allylamine hydrochloride) (PAH) and poly(methacrylic acid) (PMA) are showing an interconnected alginate matrix in the interior of the capsules. Investigations showed that the presence of alginate matrix enhances the encapsulation of cationic molecules (e.g. doxorubicin hydrochloride) manifold by charge controlled attraction mechanism. Capsule permeability investigated by confocal laser scanning microscopy revealed that the transformation from an open state to closed state is accompanied by an intermediate state where capsules are neither open nor closed. Furthermore, time dependent study indicated that the encapsulation process is linear as a function of time. The cell viability experiments demonstrated excellent biocompatibility of hollow capsules with mouse embryonic fibroblast cells. Anticancer investigations showed that DOX loaded capsules have significant anti-proliferative characteristics against HeLa cells. Such capsules have high potential for use as drug carrier for cationic drugs in cancer therapy. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. SLAC All Access: FACET

    ScienceCinema

    Hogan, Mark

    2018-02-13

    SLAC's Facility for Advanced Accelerator Experimental Tests, or FACET, is a test-bed where researchers are developing the technologies required for particle accelerators of the future. Scientists from all over the world come to explore ways of improving the power and efficiency of the particle accelerators used in basic research, medicine, industry and other areas important to society. In this video, Mark Hogan, head of SLAC's Advanced Accelerator Research Department, offers a glimpse into FACET, which uses part of SLAC's historic two-mile-long linear accelerator.

  7. Alignment and focus of mirrored facets of a heliosat

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yellowhair, Julius E; Ho, Clifford Kuofei; Diver, Richard B

    2013-11-12

    Various technologies pertaining to aligning and focusing mirrored facets of a heliostat are described herein. Updating alignment and/or focus of mirrored facets is undertaken through generation of a theoretical image, wherein the theoretical image is indicative of a reflection of the target via the mirrored facets when the mirrored facets are properly aligned. This theoretical image includes reference points that are overlaid on an image of the target as reflected by the mirrored facets of the heliostat. A technician adjusts alignment/focus of a mirrored facet by causing reflected reference markings to become aligned with the reference points in the theoreticalmore » image.« less

  8. Proximal attrition facets: morphometric, demographic, and aging characteristics.

    PubMed

    Sarig, Rachel; Hershkovitz, Israel; Shvalb, Nir; Sella-Tunis, Tatiana; May, Hila; Vardimon, Alexander D

    2014-08-01

    Although interproximal attrition is considered to be limited in modern populations, it has important clinical implications. However, in contrast to occlusal attrition, proximal attrition receives limited scientific attention. The main purpose of the current study was to fill this void. Seven-hundred and sixty-five teeth were collected from 255 skulls of subjects 18-75 yr of age. For each individual, three mandibular teeth (the first and second premolars and the first molar) were examined for proximal attrition facets (PAFs). The results provide detailed information on the size, shape, and location of the facets according to age cohort, gender, and ethnicity. The validity of the method used to measure the facets was also examined. The major findings were as follows: PAFs are usually located on the upper half of the crown proximal aspect; in each tooth, the mesial facet is more lingually positioned and the distal facet is more buccally positioned; the majority of the facets are subrectangular in shape; the size of the facets tends to increase in an anteroposterior direction (from premolars to molars); and facet size and location are age- and sex-dependent and ethnicity-independent. It is our recommendation that dentists bear in mind that interproximal attrition is a dynamic, long-term process and needs to be considered in many clinical scenarios. © 2014 Eur J Oral Sci.

  9. Mechanical role of the posterior column components in the cervical spine.

    PubMed

    Hartman, Robert A; Tisherman, Robert E; Wang, Cheng; Bell, Kevin M; Lee, Joon Y; Sowa, Gwendolyn A; Kang, James D

    2016-07-01

    To quantify the mechanical role of posterior column components in human cervical spine segments. Twelve C6-7 segments were subjected to resection of (1) suprasinous/interspinous ligaments (SSL/ISL), (2) ligamenta flavum (LF), (3) facet capsules, and (4) facets. A robot-based testing system performed repeated flexibility testing of flexion-extension (FE), axial rotation (AR), and lateral bending (LB) to 2.5Nm and replayed kinematics from intact flexibility tests for each state. Range-of-motion, stiffness, moment resistance and resultant forces were calculated. The LF contributes largely to moment resistance, particularly in flexion. Facet joints were primary contributors to AR and LB mechanics. Moment/force responses were more sensitive and precise than kinematic outcomes. The LF is mechanically important in the cervical spine; its injury could negatively impact load distribution. Damage to facets in a flexion injury could lead to AR or LB hypermobility. Quantifying the contribution of spinal structures to moment resistance is a sensitive, precise process for characterizing structural mechanics.

  10. Efficacy of Dorsoradial Capsulodesis for Trapeziometacarpal Joint Instability: A Cadaver Study.

    PubMed

    Chenoweth, Brian A; O'Mahony, Gavin D; Fitzgerald, Casey; Stoner, Julie A; O'Donoghue, Daniel L; Rayan, Ghazi M

    2017-01-01

    To test the biomechanical properties of the dorsoradial capsulodesis procedure. Six cadaveric hands were used. After exposing the trapeziometacarpal (TMC) joint, we placed Kirschner wires in the distal radius and thumb metacarpal. The rotation shear test was then performed to test the joint axial laxity, and angular measurements using Kirschner wires as reference points were documented. The dorsoradial (DR) ligament and capsule were released, followed by the intermetacarpal (IM) ligament; angular measurements were obtained. Finally, the DR capsulodesis procedure was performed, and final measurements were obtained. Comparisons were made among the various stages of ligament integrity to determine the amount of stability provided by DR capsulodesis. All cadavers demonstrated axial laxity with transection of the DR ligament; an increase in stability was obtained after DR capsulodesis. Transection of the capsule and IM ligament caused increased laxity relative to the native joint (median, 24° and 35°, respectively, on rotational testing). After we performed DR capsulodesis, rotational stability improved by a median of 41° compared with DR ligament transection, 49° compared with DR and IM ligament transection, and 18° relative to the native joint. Dorsoradial capsulodesis restores rotational stability for TMC joint after division of the DR and IM ligaments. The stability achieved was statistically significant compared with both an intact native TMC joint and induced laxity of the TMC joint. The DR capsulodesis procedure may improve rotational stability to the TMC joint. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  11. Patency© and agile© capsules

    PubMed Central

    Caunedo-Álvarez, Ángel; Romero-Vazquez, Javier; Herrerias-Gutierrez, Juan M

    2008-01-01

    Small bowel strictures can be missed by current diagnostic methods. The Patency capsule is a new non-endoscopic dissolvable capsule which has as an objective of checking the patency of digestive tract, in a non-invasive manner. The available clinical trials have demonstrated that the Patency© capsule is a good tool for assessment of the functional patency of the small bowel, and it allows identification of those patients who can safely undergo a capsule endoscopy, despite clinical and radiographic evidence of small-bowel obstruction. Some cases of intestinal occlusion have been reported with the Patency© capsule, four of them needed surgery. So, a new capsule with two timer plugs (Agile© capsule) has been recently developed in order to minimize the risk of occlusion. This new device stars its dissolution process earlier (30 h after ingestion) and its two timer plugs have been designed to begin the disintegration even when the device is blocked in a tight stricture. PMID:18785278

  12. Scalable Faceted Ranking in Tagging Systems

    NASA Astrophysics Data System (ADS)

    Orlicki, José I.; Alvarez-Hamelin, J. Ignacio; Fierens, Pablo I.

    Nowadays, web collaborative tagging systems which allow users to upload, comment on and recommend contents, are growing. Such systems can be represented as graphs where nodes correspond to users and tagged-links to recommendations. In this paper we analyze the problem of computing a ranking of users with respect to a facet described as a set of tags. A straightforward solution is to compute a PageRank-like algorithm on a facet-related graph, but it is not feasible for online computation. We propose an alternative: (i) a ranking for each tag is computed offline on the basis of tag-related subgraphs; (ii) a faceted order is generated online by merging rankings corresponding to all the tags in the facet. Based on the graph analysis of YouTube and Flickr, we show that step (i) is scalable. We also present efficient algorithms for step (ii), which are evaluated by comparing their results with two gold standards.

  13. Magnetically guided capsule endoscopy.

    PubMed

    Shamsudhin, Naveen; Zverev, Vladimir I; Keller, Henrik; Pane, Salvador; Egolf, Peter W; Nelson, Bradley J; Tishin, Alexander M

    2017-08-01

    Wireless capsule endoscopy (WCE) is a powerful tool for medical screening and diagnosis, where a small capsule is swallowed and moved by means of natural peristalsis and gravity through the human gastrointestinal (GI) tract. The camera-integrated capsule allows for visualization of the small intestine, a region which was previously inaccessible to classical flexible endoscopy. As a diagnostic tool, it allows to localize the sources of bleedings in the middle part of the gastrointestinal tract and to identify diseases, such as inflammatory bowel disease (Crohn's disease), polyposis syndrome, and tumors. The screening and diagnostic efficacy of the WCE, especially in the stomach region, is hampered by a variety of technical challenges like the lack of active capsular position and orientation control. Therapeutic functionality is absent in most commercial capsules, due to constraints in capsular volume and energy storage. The possibility of using body-exogenous magnetic fields to guide, orient, power, and operate the capsule and its mechanisms has led to increasing research in Magnetically Guided Capsule Endoscopy (MGCE). This work shortly reviews the history and state-of-art in WCE technology. It highlights the magnetic technologies for advancing diagnostic and therapeutic functionalities of WCE. Not restricting itself to the GI tract, the review further investigates the technological developments in magnetically guided microrobots that can navigate through the various air- and fluid-filled lumina and cavities in the body for minimally invasive medicine. © 2017 American Association of Physicists in Medicine.

  14. Histological study of the human temporo-mandibular joint and its surrounding muscles.

    PubMed

    Bravetti, P; Membre, H; El Haddioui, A; Gérard, H; Fyard, J P; Mahler, P; Gaudy, J F

    2004-10-01

    This is a histological study of the human temporo-mandibular joint and its surrounding muscles. Using a microscopic study of serial sections from anatomical specimens from six subjects, the detailed anatomy of the joint is presented with particular regard to the histology. This study has allowed, in particular, the description of the ligaments and capsule as well as the insertions of the masticatory muscles (temporalis, masseter, lateral pterygoid) on this joint. These observations are then compared with the anatomical and histological data already reported on this subject. This study shows that the bulk of the muscular fibres of the lateral pterygoid passes under the foot of the disc is attached over the whole height of the condylar, unite and extend as far as the medial pole of the joint under the insertion of the articular disc. An insertion of the temporo-masseter musculo-tendinous complex on the anterior and lateral capsulo-discal structures was observed. The lateral pterygoid is composed of a succession of tendinous and fleshy fibres. This study confirms the thickening of the lateral capsule that corresponds to a lateral collateral ligament, and the absence of a medial collateral ligament. Medial stability is conferred by the lateral ligament of the contralateral joint.

  15. Low-energy gamma ray inspection of brazed aluminum joints

    NASA Technical Reports Server (NTRS)

    Brown, J. A.

    1967-01-01

    Americium 241 serves as a suitable radioisotope /gamma ray source/ and exposure probe for radiographic inspection of brazed aluminum joints in areas of limited accessibility. The powdered isotope is contained in a sealed capsule mounted at the end of a spring-loaded pushrod in the probe assembly.

  16. Biomechanical Effects of Acromioplasty on Superior Capsule Reconstruction for Irreparable Supraspinatus Tendon Tears.

    PubMed

    Mihata, Teruhisa; McGarry, Michelle H; Kahn, Timothy; Goldberg, Iliya; Neo, Masashi; Lee, Thay Q

    2016-01-01

    % of intact [P = .002]) and subacromial peak contact pressure (0° of abduction: 47% of intact [P = .0002]; 30° of abduction: 83% of intact [P = .0005]; 60° of abduction: 38% of intact [P = .04]) compared with after the creation of a supraspinatus tear. Adding acromioplasty significantly decreased the subacromial contact area compared with superior capsule reconstruction without acromioplasty (0° of abduction: 26% decrease [P = .01]; 30° of abduction: 21% decrease [P = .009]; 60° of abduction: 61% decrease [P = .003]) and did not alter humeral head position, superior translation, or subacromial peak contact pressure. Superior capsule reconstruction repositioned the superiorly migrated humeral head and restored superior stability in the shoulder joint. Adding acromioplasty decreased the subacromial contact area without increasing the subacromial contact pressure. When superior capsule reconstruction is performed for irreparable rotator cuff tears, acromioplasty may help to decrease the postoperative risk of abrasion and tearing of the graft beneath the acromion. © 2015 The Author(s).

  17. SLAC Linac Preparations for FACET

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Erickson, R.; Bentson, L.; Kharakh, D.

    The SLAC 3km linear electron accelerator has been cut at the two-thirds point to provide beams to two independent programs. The last third provides the electron beam for the Linac Coherent Light Source (LCLS), leaving the first two-thirds available for FACET, the new experimental facility for accelerator science and test beams. In this paper, we describe this separation and projects to prepare the linac for the FACET experimental program.

  18. Stennis time capsule

    NASA Image and Video Library

    2011-10-15

    Stennis Space Center Director Patrick Scheuermann (right) and Naval Meteorology and Oceanography Command Chief of Staff James Pettigrew drop the first shovelfuls of dirt on a time capsule to be opened on the rocket engine test facility's 100th anniversary in 2061. The time capsule was placed in front of the Roy S. Estess Building on Oct. 25 as Stennis concluded celebrations of its 50th anniversary.

  19. Anisotropic surface melting in lyotropic cubic crystals: part 2: facet-by-facet melting at Ia3d/vapor interfaces.

    PubMed

    Leroy, S; Grenier, J; Rohe, D; Even, C; Pieranski, P

    2006-05-01

    From experiments with metal crystals, in the vicinity of their crystal/liquid/vapor triple points, it is known that melting of crystals starts on their surfaces and is anisotropic. Recently, we have shown that anisotropic surface melting occurs also in lyotropic systems. In our previous paper (Eur. Phys. J. E 19, 223 (2006)), we have focused on the case of poor faceting at the Pn3m/L1 interface in C12EO2/water binary mixtures. There anisotropic melting occurs in the vicinity of a Pn3m/L3/L1 triple point. In the present paper, we focus on the opposite case of a rich devil's-staircase-type faceting at Ia3d/vapor interfaces in monoolein/water and phytantriol/water mixtures. We show that anisotropic surface melting takes place in these systems in a narrow humidity range close to the Ia3d-L2 transition. As whole (hkl) sets of facets disappear one after another when the transition is approached, surface melting occurs in a facet-by-facet type.

  20. Distraction Arthrodesis of the C1-C2 Facet Joint with Preservation of the C2 Root for the Management of Intractable Occipital Neuralgia Caused by C2 Root Compression.

    PubMed

    Yeom, Jin S; Riew, K Daniel; Kang, Sung Shik; Yi, Jemin; Lee, Gun Woo; Yeom, Arim; Chang, Bong-Soon; Lee, Choon-Ki; Kim, Ho-Joong

    2015-10-15

    Prospective observational cohort study. To compare the outcomes of our new technique, distraction arthrodesis of C1-C2 facet joint with C2 root preservation (Study group), to those of conventional C1-C2 fusion with C2 root transection (Control group) for the management of intractable occipital neuralgia caused by C2 root compression. We are not aware of any report concerning C2 root decompression during C1-C2 fusion. Inclusion criteria were visual analogue scale (VAS) score for occipital neuralgia 7 or more; C2 root compression at the collapsed C1-C2 neural foramen; and follow-up 12 months or more. The Study group underwent surgery with our new technique including (1) C1-C2 facet joint distraction and bone block insertion while preserving the C2 root; and (2) use of C1 posterior arch screws instead of conventional lateral mass screws during C1-C2 segmental screw fixation. The Control group underwent C2 root transection with C1-C2 segmental screw fixation and fusion. We compared the prospectively collected outcomes data. There were 15 patients in the Study group and 8 in the Control group. Although there was no significant difference in the VAS score for the occipital neuralgia between the 2 groups preoperatively (8.2 ± 0.9 vs. 7.9 ± 0.6, P = 0.39), it was significantly lower in the Study group at 1, 3, and 6 months postoperatively (P < 0.01, respectively). At 12 months, it was 0.4 ± 0.6 versus 2.5 ± 2.6 (P = 0.01). There was no significant difference in improvement in the VAS score for neck pain and neck disability index and Japanese Orthopedic Association recovery rate, which are minimally influenced by occipital neuralgia. Our novel technique of distraction arthrodesis with C2 root preservation can be an effective option for the management of intractable occipital neuralgia caused by C2 root compression.

  1. Enteric-coating of pulsatile-release HPC capsules prepared by injection molding.

    PubMed

    Macchi, E; Zema, L; Maroni, A; Gazzaniga, A; Felton, L A

    2015-04-05

    Capsular devices based on hydroxypropyl cellulose (Klucel® LF) intended for pulsatile release were prepared by injection molding (IM). In the present work, the possibility of exploiting such capsules for the development of colonic delivery systems based on a time-dependent approach was evaluated. For this purpose, it was necessary to demonstrate the ability of molded cores to undergo a coating process and that coated systems yield the desired performance (gastric resistance). Although no information was available on the coating of IM substrates, some issues relevant to that of commercially-available capsules are known. Thus, preliminary studies were conducted on molded disks for screening purposes prior to the spray-coating of HPC capsular cores with Eudragit® L 30 D 55. The ability of the polymeric suspension to wet the substrate, spread, start penetrating and initiate hydration/swelling, as well as to provide a gastroresistant barrier was demonstrated. The coating of prototype HPC capsules was carried out successfully, leading to coated systems with good technological properties and able to withstand the acidic medium with no need for sealing at the cap/body joint. Such systems maintained the original pulsatile release performance after dissolution of the enteric film in pH 6.8 fluid. Therefore, they appeared potentially suitable for the development of a colon delivery platform based on a time-dependent approach. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Agile patency system eliminates risk of capsule retention in patients with known intestinal strictures who undergo capsule endoscopy.

    PubMed

    Herrerias, Juan M; Leighton, Jonathan A; Costamagna, Guido; Infantolino, Anthony; Eliakim, Rami; Fischer, Doron; Rubin, David T; Manten, Howard D; Scapa, Eitan; Morgan, Douglas R; Bergwerk, Ari J; Koslowsky, Binyamin; Adler, Samuel N

    2008-05-01

    Capsule endoscopy (CE) of the small bowel has become a standard diagnostic tool, but there have been concerns regarding the risk of capsule retention in certain high-risk groups. The Agile patency system, an ingestible and dissolvable capsule with an external scanner, was developed to allow physicians to perform CE with greater confidence that the capsule will be safely excreted in patients at risk for capsule retention. Our purpose was to assess the ability of the device to help physicians identify which patients with known strictures may safely undergo CE. Patients with known strictures ingested the new patency capsule and underwent periodic scanning until it was excreted. The intestinal tract was considered to be sufficiently patent if the capsule was excreted intact or if the capsule was not detected by the scanner at 30 hours after ingestion. If patency was established, then standard CE was performed. International multicenter study. A total of 106 patients with known strictures. Agile patency system. Performance and safety of Agile patency system. A total of 106 patients ingested the patency capsule. Fifty-nine (56%) excreted it intact and subsequently underwent CE. There were no cases of capsule retention. Significant findings on CE were found in 24 (41%). There were 3 severe adverse events. These results suggest that the Agile patency system is a useful tool for physicians to use before CE in patients with strictures to avoid retention. This group of patients may have a high yield of clinically significant findings at CE. This capsule may determine whether patients who have a contraindication to CE may safely undergo CE and obtain useful diagnostic information.

  3. Endoscopic placement of the small-bowel video capsule by using a capsule endoscope delivery device.

    PubMed

    Holden, Jeremy P; Dureja, Parul; Pfau, Patrick R; Schwartz, Darren C; Reichelderfer, Mark; Judd, Robert H; Danko, Istvan; Iyer, Lalitha V; Gopal, Deepak V

    2007-05-01

    Capsule endoscopy performed via the traditional peroral route is technically challenging in patients with dysphagia, gastroparesis, and/or abnormal upper-GI (UGI) anatomy. To describe the indications and outcomes of cases in which the AdvanCE capsule endoscope delivery device, which has recently been cleared by the Food and Drug Administration, was used. Retrospective, descriptive, case series. Tertiary care, university hospital. We report a case series of 16 consecutive patients in whom the AdvanCE delivery device was used. The study period was May 2005 through July 2006. Endoscopic delivery of the video capsule to the proximal small bowel by using the AdvanCE delivery device. Indications, technique, and completeness of small bowel imaging in patients who underwent endoscopic video capsule delivery. The AdvanCE delivery device was used in 16 patients ranging in age from 3 to 74 years. The primary indications for endoscopic delivery included inability to swallow the capsule (10), altered UGI anatomy (4), and gastroparesis (2). Of the 4 patients with altered UGI anatomy, 3 had dual intestinal loop anatomy (ie, Bilroth-II procedure, Whipple surgery, Roux-en-Y gastric bypass) and 1 had a failed Nissen fundoplication. In all cases, the capsule was easily deployed without complication, and complete small intestinal imaging was achieved. Small patient size. Endoscopic placement of the Given PillCam by use of the AdvanCE delivery device was safe and easily performed in patients for whom capsule endoscopy would otherwise have been contraindicated or technically challenging.

  4. Migration mechanisms of a faceted grain boundary

    NASA Astrophysics Data System (ADS)

    Hadian, R.; Grabowski, B.; Finnis, M. W.; Neugebauer, J.

    2018-04-01

    We report molecular dynamics simulations and their analysis for a mixed tilt and twist grain boundary vicinal to the Σ 7 symmetric tilt boundary of the type {1 2 3 } in aluminum. When minimized in energy at 0 K , a grain boundary of this type exhibits nanofacets that contain kinks. We observe that at higher temperatures of migration simulations, given extended annealing times, it is energetically favorable for these nanofacets to coalesce into a large terrace-facet structure. Therefore, we initiate the simulations from such a structure and study as a function of applied driving force and temperature how the boundary migrates. We find the migration of a faceted boundary can be described in terms of the flow of steps. The migration is dominated at lower driving force by the collective motion of the steps incorporated in the facet, and at higher driving forces by the step detachment from the terrace-facet junction and propagation of steps across the terraces. The velocity of steps on terraces is faster than their velocity when incorporated in the facet, and very much faster than the velocity of the facet profile itself, which is almost stationary. A simple kinetic Monte Carlo model matches the broad kinematic features revealed by the molecular dynamics. Since the mechanisms seem likely to be very general on kinked grain-boundary planes, the step-flow description is a promising approach to more quantitative modeling of general grain boundaries.

  5. CT of facet distraction in flexion injuries of the thoracolumbar spine: the "naked" facet.

    PubMed

    O'Callaghan, J P; Ullrich, C G; Yuan, H A; Kieffer, S A

    1980-03-01

    Vertical distraction of the articular processes is an important sign of ligamentous disruption due to flexion injuries of the thoracolumbar spine. In addition to illustrating this finding in cross section (the "naked" facet), computed tomography in the transaxial plane allows assessment of the presence and position of fracture fragments that may encroach on the spinal canal. Image reconstruction in sagittal and coronal planes provides a clear demonstration of the degree of bony compression, facet distraction, and kyphosis associated with flexion injuries without additional patient manipulation or radiation exposure.

  6. Method for partially coating laser diode facets

    NASA Technical Reports Server (NTRS)

    Dholakia, Anil R. (Inventor)

    1990-01-01

    Bars of integral laser diode devices cleaved from a wafer are placed with their p regions abutting and n regions abutting. A thin BeCu mask having alternate openings and strips of the same width as the end facets is used to mask the n region interfaces so that multiple bars can be partially coated over their exposed p regions with a reflective or partial reflective coating. The partial coating permits identification of the emitting facet from the fully coated back facet during a later device mounting procedure.

  7. A model for the geomorphic development of normal-fault facets

    NASA Astrophysics Data System (ADS)

    Tucker, G. E.; Hobley, D. E. J.; McCoy, S. W.

    2014-12-01

    Triangular facets are among the most striking landforms associated with normal faulting. The genesis of facets is of great interest both for the information facets contain about tectonic motion, and because the progressive emergence of facets makes them potential recorders of both geomorphic and tectonic history. In this report, we present observations of triangular facets in the western United States and in the Italian Central Apennines. Facets in these regions typically form quasi-planar surfaces that are aligned in series along and above the trace of an active fault. Some facet surfaces consist mainly of exposed bedrock, with a thin and highly discontinuous cover of loose regolith. Other facets are mantled by a several-decimeter-thick regolith cover. Over the course of its morphologic development, a facet slope segment may evolve from a steep (~60 degree) bedrock fault scarp, well above the angle of repose for soil, to a gentler (~20-40 degree) slope that can potentially sustain a coherent regolith cover. This evolutionary trajectory across the angle of repose renders nonlinear diffusion theory inapplicable. To formulate an alternative process-based theory for facet evolution, we use a particle-based approach that acknowledges the possibility for both short- and long-range sediment-grain motions, depending on the topography. The processes of rock weathering, grain entrainment, and grain motion are represented as stochastic state-pair transitions with specified transition rates. The model predicts that facet behavior can range smoothly along the spectrum from a weathering-limited mode to a transport-limited mode, depending on the ratio of fault-slip rate to bare-bedrock regolith production rate. The model also implies that facets formed along a fault with pinned tips should show systematic variation in slope angle that correlates with along-fault position and slip rate. Preliminary observations from central Italy and the eastern Basin and Range are consistent

  8. Sagittal distal limb kinematics inside the hoof capsule captured using high-speed fluoroscopy in walking and trotting horses.

    PubMed

    Roach, J M; Pfau, T; Bryars, J; Unt, V; Channon, S B; Weller, R

    2014-10-01

    Kinematic evaluation of the distal limb of the horse using standard methods is challenging, mainly due to the hoof capsule restricting visualisation, but the recent development of a high-speed fluoroscopy (HSF) system has allowed in vivo cineradiographic assessment of moving skeletal structures at high speeds. The application of this non-invasive method to the equine distal limb is used to describe 'internal' distal limb kinematics including intra-horse and inter-horse variability, and variability between walk and trot. Distal limb kinematic data were collected at walk and trot from six non-lame horses using HSF set over a force plate. The dorsal proximal interphalangeal joint (PIPJ) angle and the dorsal distal interphalangeal joint (DIPJ) angle were measured at toe-on and at 25%, 50% and 75% of stance. The PIPJ and DIPJ showed overall extension through stance. The mean ± SD range of motion (ROM) during stance of the PIPJ was 9.7 ± 2.7° (walk) and 8.7 ± 3.0° (trot) and of the DIPJ was 28.6 ± 4.6° (walk) and 26.5 ± 6.3° (trot) showing significant differences between gaits and changes through stance (P < 0.001). Inter- and intra- horse variations were also significant for both joint angles (P < 0.001). HSF allowed for kinematic assessment of the distal limb within the hoof capsule. The ROM of the PIPJ observed was similar to results published in the literature whilst the ROM for the DIPJ was less than values previously reported. Future studies will use HSF to estimate strain in the tendons and ligaments within the hoof capsule, which are a common site of lameness in the horse. Copyright © 2014. Published by Elsevier Ltd.

  9. Capsule Escape Tests - Wallops Island

    NASA Image and Video Library

    1959-05-14

    Caption: Off the pad abort shot at Wallops using Langley PARD designed full scale capsule with Recruit rocket and extended skirt main parachute. Shows sequential images of launch and capsule splashdown.

  10. Contraception with subdermal ST-1435 capsules: side-effects, endocrine profiles and liver function related to different lengths of capsules.

    PubMed

    Kurunmäki, H; Toivonen, J; Lähteenmäki, P; Luukkainen, T

    1985-03-01

    One Silastic capsule of 15 mm, 20 mm or 30 mm length was inserted subcutaneously into the ventral aspect of the left forearm or upper arm of 28 healthy women during menstrual bleeding or not later than on the seventh day of the menstrual cycle. A new capsule of the same length was inserted after six months and both capsules were removed twelve months after the first insertion. Side-effects, including changes in body weight, blood pressure, menstrual bleeding and liver function test results, were registered. Blood samples were taken from selected subjects twice a week during the 1st, 2nd, 3rd, 6th, 7th and 12th month of use. Plasma concentrations of ST-1435 were measured by radioimmunoassay and the effects of treatment on pituitary and ovarian function were determined by assaying plasma concentrations of LH, FSH, estradiol and progesterone. There were no differences in hormonal side-effects between subjects who had a 30 mm capsule or subjects who had 20 mm or 15 mm capsules, but subjects who had 20 or 15 mm capsules had significantly longer bleeding or spotting periods in comparison with subjects who had a 30 mm capsule. There were no changes in blood pressure, body weight or liver function test results in comparison with pre-insertion values. The plasma level of ST-1435 was not significantly higher during the use of 30 mm capsules than during the use of 20 or 15 mm capsules. During the use of the shorter ST-1435 capsules, plasma estradiol elevation and slightly suppressed FSH were seen, while the use of longer capsules resulted in a slight suppression of LH. Progesterone concentrations during monitored cycles indicated anovulation. No pregnancies occurred during the study period of one year. The continuation rate at one year was 71% in the 30 mm capsule group and 57% in the 20 and 15 mm capsule groups taken together.

  11. Dynamic properties of human incudostapedial joint-Experimental measurement and finite element modeling.

    PubMed

    Jiang, Shangyuan; Gan, Rong Z

    2018-04-01

    The incudostapedial joint (ISJ) is a synovial joint connecting the incus and stapes in the middle ear. Mechanical properties of the ISJ directly affect sound transmission from the tympanic membrane to the cochlea. However, how ISJ properties change with frequency has not been investigated. In this paper, we report the dynamic properties of the human ISJ measured in eight samples using a dynamic mechanical analyzer (DMA) for frequencies from 1 to 80 Hz at three temperatures of 5, 25 and 37 °C. The frequency-temperature superposition (FTS) principle was used to extrapolate the results to 8 kHz. The complex modulus of ISJ was measured with a mean storage modulus of 1.14 MPa at 1 Hz that increased to 3.01 MPa at 8 kHz, and a loss modulus that increased from 0.07 to 0.47 MPa. A 3-dimensional finite element (FE) model consisting of the articular cartilage, joint capsule and synovial fluid was then constructed to derive mechanical properties of ISJ components by matching the model results to experimental data. Modeling results showed that mechanical properties of the joint capsule and synovial fluid affected the dynamic behavior of the joint. This study contributes to a better understanding of the structure-function relationship of the ISJ for sound transmission. Copyright © 2018. Published by Elsevier Ltd.

  12. Strength Variation of Parachute Joints

    NASA Technical Reports Server (NTRS)

    Mollmann, Catherine

    2017-01-01

    A parachute joint is defined as a location where a component is sewn or connected to another component. During the design and developmental phase of a parachute system, the joints for each structural component are isolated and tested through a process called seam and joint testing. The objective of seam and joint testing is to determine the degradation on a single component due to interaction with other components; this data is then used when calculating the margin of safety for that component. During the engineering developmental phase of CPAS (Capsule Parachute Assembly System), the parachute system for the NASA Orion Crew Module, testing was completed for every joint of the six subsystems: the four parachutes (main, drogue, pilot, and FBCP [forward bay cover parachute]), the retention release bridle, and the retention panels. The number of joint tests for these subsystems totaled 92, which provides a plethora of data and results for further analysis. In this paper, the data and results of these seam and joint tests are examined to determine the effects, if any, of different operators and sewing machines on the strength of parachute joints. Other variables are also studied to determine their effect on joint strength, such as joint complexity, joint strength magnitude, material type, and material construction. Findings reveal that an optimally-run seam and joint test program could result in an increased understanding of the structure of the parachute; this should lead to a parachute built with optimal components, potentially saving system weight and volume.

  13. First order capsules comparative arrangements

    NASA Technical Reports Server (NTRS)

    1963-01-01

    Pen and ink views of comparative arragements of several capsules including the existing 'Big Joe' design, the compromise 'Big Joe' design, and the 'Little Joe'. All capsule designs are labeled and include dimensions.

  14. Nanocomposite capsules with directional, pulsed nanoparticle release.

    PubMed

    Udoh, Christiana E; Cabral, João T; Garbin, Valeria

    2017-12-01

    The precise spatiotemporal delivery of nanoparticles from polymeric capsules is required for applications ranging from medicine to materials science. These capsules derive key performance aspects from their overall shape and dimensions, porosity, and internal microstructure. To this effect, microfluidics provide an exceptional platform for emulsification and subsequent capsule formation. However, facile and robust approaches for nanocomposite capsule fabrication, exhibiting triggered nanoparticle release, remain elusive because of the complex coupling of polymer-nanoparticle phase behavior, diffusion, phase inversion, and directional solidification. We investigate a model system of polyelectrolyte sodium poly(styrene sulfonate) and 22-nm colloidal silica and demonstrate a robust capsule morphology diagram, achieving a range of internal morphologies, including nucleated and bicontinuous microstructures, as well as isotropic and non-isotropic external shapes. Upon dissolution in water, we find that capsules formed with either neat polymers or neat nanoparticles dissolve rapidly and isotropically, whereas bicontinuous, hierarchical, composite capsules dissolve via directional pulses of nanoparticle clusters without disrupting the scaffold, with time scales tunable from seconds to hours. The versatility, facile assembly, and response of these nanocomposite capsules thus show great promise in precision delivery.

  15. Gelatin capsule in stomach (image)

    MedlinePlus

    ... detect the presence of intestinal parasites. A weighted gelatin capsule attached to a string is swallowed and left in place. After about 4 hours, the gelatin capsule is pulled out of the stomach by ...

  16. Thermoregulation of Capsule Production by Streptococcus pyogenes

    PubMed Central

    Kang, Song Ok; Wright, Jordan O.; Tesorero, Rafael A.; Lee, Hyunwoo; Beall, Bernard; Cho, Kyu Hong

    2012-01-01

    The capsule of Streptococcus pyogenes serves as an adhesin as well as an anti-phagocytic factor by binding to CD44 on keratinocytes of the pharyngeal mucosa and the skin, the main entry sites of the pathogen. We discovered that S. pyogenes HSC5 and MGAS315 strains are further thermoregulated for capsule production at a post-transcriptional level in addition to the transcriptional regulation by the CovRS two-component regulatory system. When the transcription of the hasABC capsular biosynthetic locus was de-repressed through mutation of the covRS system, the two strains, which have been used for pathogenesis studies in the laboratory, exhibited markedly increased capsule production at sub-body temperature. Employing transposon mutagenesis, we found that CvfA, a previously identified membrane-associated endoribonuclease, is required for the thermoregulation of capsule synthesis. The mutation of the cvfA gene conferred increased capsule production regardless of temperature. However, the amount of the capsule transcript was not changed by the mutation, indicating that a post-transcriptional regulator mediates between CvfA and thermoregulated capsule production. When we tested naturally occurring invasive mucoid strains, a high percentage (11/53, 21%) of the strains exhibited thermoregulated capsule production. As expected, the mucoid phenotype of these strains at sub-body temperature was due to mutations within the chromosomal covRS genes. Capsule thermoregulation that exhibits high capsule production at lower temperatures that occur on the skin or mucosal surface potentially confers better capability of adhesion and invasion when S. pyogenes penetrates the epithelial surface. PMID:22615992

  17. Big Joe Capsule Assembly Activities

    NASA Image and Video Library

    1959-08-01

    Big Joe Capsule Assembly Activities in 1959 at NASA Glenn Research Center (formerly NASA Lewis). Big Joe was an Atlas missile that successfully launched a boilerplate model of the Mercury capsule on September 9, 1959.

  18. The effects of hematoma on implant capsules.

    PubMed

    Caffee, H H

    1986-02-01

    Hematoma surrounding an implant is one of the many factors that have been suggested as possible causes for scar capsule contracture. In this study, experiments were designed to determine the influence of hematoma on the incidence and severity of capsule contracture in rabbits. Two implants were placed in each animal, 1 with a surrounding hematoma and 1 control. Capsules were evaluated subjectively and compared objectively with measurements of deformability, surface area, and capsule thickness. No differences were found with any of the objective criteria, which suggests that hematoma may not be a noteworthy cause of implant capsule contracture.

  19. Lumbar facet anatomy changes in spondylolysis: a comparative skeletal study.

    PubMed

    Masharawi, Youssef; Dar, Gali; Peleg, Smadar; Steinberg, Nili; Alperovitch-Najenson, Dvora; Salame, Khalil; Hershkovitz, Israel

    2007-07-01

    Opinions differ as to the exact mechanism responsible for spondylolysis (SP) and whether individuals with specific morphological characteristics of the lumbar vertebral neural arch are predisposed to SP. The aim of our study was to reveal the association between SP and the architecture of lumbar articular facets and the inter-facet region. Using a Microscribe three-dimensional apparatus (Immersion Co., San Jose, CA, USA), length, width and depth of all articular facets and all inter-facet distances in the lumbar spine (L1-L5) were measured. From the Hamann-Todd Human Osteological Collection (Cleveland Museum of Natural History, OH, USA) 120 normal male skeletons with lumbar spines in the control group and 115 with bilateral SP at L5 were selected. Analysis of variance was employed to examine the differences between spondylolytic and normal spines. Three profound differences between SP and the norm appeared: (1) in individuals with SP, the size and shape of L4's neural arch had significantly greater inter-facet widths, significantly shorter inter-facet heights and significantly shorter and narrower articular facets; (2) only in the L4 vertebra in individuals with SP was the inferior inter-facet width greater in size than the superior inter-facet width of the vertebra below (L5) (38.7 mm versus 40 mm); (3) in all lumbar vertebrae, the right inferior articular facets in individuals with SP were flatter compared to the control group. Individuals with L4 "SP" characteristics are at a greater risk of developing fatigue fractures in the form of spondylolysis at L5.

  20. Evolution of triangular topographic facets along active normal faults

    NASA Astrophysics Data System (ADS)

    Balogun, A.; Dawers, N. H.; Gasparini, N. M.; Giachetta, E.

    2011-12-01

    Triangular shaped facets, which are generally formed by the erosion of fault - bounded mountain ranges, are arguably one of the most prominent geomorphic features on active normal fault scarps. Some previous studies of triangular facet development have suggested that facet size and slope exhibit a strong linear dependency on fault slip rate, thus linking their growth directly to the kinematics of fault initiation and linkage. Other studies, however, generally conclude that there is no variation in triangular facet geometry (height and slope) with fault slip rate. The landscape of the northeastern Basin and Range Province of the western United States provides an opportunity for addressing this problem. This is due to the presence of well developed triangular facets along active normal faults, as well as spatial variations in fault scale and slip rate. In addition, the Holocene climatic record for this region suggests a dominant tectonic regime, as the faulted landscape shows little evidence of precipitation gradients associated with tectonic uplift. Using GIS-based analyses of USGS 30 m digital elevation data (DEMs) for east - central Idaho and southwestern Montana, we analyze triangular facet geometries along fault systems of varying number of constituent segments. This approach allows us to link these geometries with established patterns of along - strike slip rate variation. For this study, we consider major watersheds to include only catchments with upstream and downstream boundaries extending from the drainage divide to the mapped fault trace, respectively. In order to maintain consistency in the selection criteria for the analyzed triangular facets, only facets bounded on opposite sides by major watersheds were considered. Our preliminary observations reflect a general along - strike increase in the surface area, average slope, and relief of triangular facets from the tips of the fault towards the center. We attribute anomalies in the along - strike geometric

  1. Thickening of the inferior glenohumeral capsule: an ultrasound sign for shoulder capsular contracture.

    PubMed

    Michelin, Paul; Delarue, Yohann; Duparc, Fabrice; Dacher, Jean Nicolas

    2013-10-01

    The aim of this retrospective study was to measure the inferior glenohumeral capsule thickness of shoulders clinically affected by capsular contracture by comparison to the contralateral asymptomatic side. Bilateral shoulder ultrasound (US) examinations of 20 patients with clinically or MRI proven unilateral capsular contracture were retrospectively assessed. Inferior capsule evaluation was performed with a transducer placed within the axilla in maximally abducted shoulders. Measurements were symmetrically performed orthogonally to the inferior glenohumeral ligament (IGHL) in the axial plane; the coronal plane was used to ensure the tension of the IGHL. The significance of any difference in thickening was assessed with the Mann-Whitney test. The average thickness was 4.0 mm in shoulders with capsular contracture vs. 1.3 mm in asymptomatic contralateral shoulders (P < 0.0001). Twenty per cent of patients with capsular contracture and inferior capsule thickness increase showed US features of other painful diseases of the rotator cuff. The thickness of the inferior capsule is measurable through ultrasound examination and appears to be increased in shoulders with capsular contracture. Exploration of the inferior aspect of the shoulder joint could be added to shoulder US examination protocols for capsular contracture assessment even if other rotator cuff abnormalities are diagnosed by US. • Ultrasound is increasingly used to diagnose shoulder problems. • The thickness of the inferior glenohumeral ligament is measurable in the axilla. • The inferior glenohumeral ligament appears thickened in shoulders with capsular contracture. • Capsular contracture ultrasound features can be associated with other rotator cuff problems.

  2. Facet Annotation by Extending CNN with a Matching Strategy.

    PubMed

    Wu, Bei; Wei, Bifan; Liu, Jun; Guo, Zhaotong; Zheng, Yuanhao; Chen, Yihe

    2018-06-01

    Most community question answering (CQA) websites manage plenty of question-answer pairs (QAPs) through topic-based organizations, which may not satisfy users' fine-grained search demands. Facets of topics serve as a powerful tool to navigate, refine, and group the QAPs. In this work, we propose FACM, a model to annotate QAPs with facets by extending convolution neural networks (CNNs) with a matching strategy. First, phrase information is incorporated into text representation by CNNs with different kernel sizes. Then, through a matching strategy among QAPs and facet label texts (FaLTs) acquired from Wikipedia, we generate similarity matrices to deal with the facet heterogeneity. Finally, a three-channel CNN is trained for facet label assignment of QAPs. Experiments on three real-world data sets show that FACM outperforms the state-of-the-art methods.

  3. Stennis time capsule

    NASA Image and Video Library

    2011-10-15

    Stennis Space Center Director Patrick Scheuermann (right) and Naval Meteorology and Oceanography Command Chief of Staff James Pettigrew drop the first shovelfuls of dirt on a time capsule to be opened on the rocket engine test facility's 100th anniversary in 2061. The time capsule was placed in front of the Roy S. Estess Building on Oct. 25 as Stennis concluded celebrations of its 50th anniversary. NASA publicly announced plans to build the rocket engine test site Oct. 25, 1961.

  4. Formulation and Application of the Generalized Multilevel Facets Model

    ERIC Educational Resources Information Center

    Wang, Wen-Chung; Liu, Chih-Yu

    2007-01-01

    In this study, the authors develop a generalized multilevel facets model, which is not only a multilevel and two-parameter generalization of the facets model, but also a multilevel and facet generalization of the generalized partial credit model. Because the new model is formulated within a framework of nonlinear mixed models, no efforts are…

  5. Small intestinal model for electrically propelled capsule endoscopy

    PubMed Central

    2011-01-01

    The aim of this research is to propose a small intestine model for electrically propelled capsule endoscopy. The electrical stimulus can cause contraction of the small intestine and propel the capsule along the lumen. The proposed model considered the drag and friction from the small intestine using a thin walled model and Stokes' drag equation. Further, contraction force from the small intestine was modeled by using regression analysis. From the proposed model, the acceleration and velocity of various exterior shapes of capsule were calculated, and two exterior shapes of capsules were proposed based on the internal volume of the capsules. The proposed capsules were fabricated and animal experiments were conducted. One of the proposed capsules showed an average (SD) velocity in forward direction of 2.91 ± 0.99 mm/s and 2.23 ± 0.78 mm/s in the backward direction, which was 5.2 times faster than that obtained in previous research. The proposed model can predict locomotion of the capsule based on various exterior shapes of the capsule. PMID:22177218

  6. Eight Key Facets of Small Business Management.

    ERIC Educational Resources Information Center

    Scott, James Calvert

    1980-01-01

    Identifies eight key facets of small business management and suggests activities that may be used to assist in their development. The key facets are (1) product or service, (2) competition, (3) marketing strategies, (4) personnel needs, (5) equipment and facility needs, (6) finances, (7) planning, and (8) entrepreneurship. (JOW)

  7. Contraindications for video capsule endoscopy

    PubMed Central

    Bandorski, Dirk; Kurniawan, Niehls; Baltes, Peter; Hoeltgen, Reinhard; Hecker, Matthias; Stunder, Dominik; Keuchel, Martin

    2016-01-01

    Video capsule endoscopy (VCE) has been applied in the last 15 years in an increasing field of applications. Although many contraindications have been put into perspective, some precautions still have to be considered. Known stenosis of the gastrointestinal tract is a clear contraindication for VCE unless surgery is already scheduled or at least has been considered as an optional treatment modality. In patients with a higher incidence of stenosis, as in an established diagnosis of Crohn’s disease, clinical signs of obstruction, prior radiation or surgical small bowel resection, a preceding test with the self-dissolving patency capsule can override this contraindication. Endoscopic placement of the capsule should be considered in patients with swallowing disorders to avoid aspiration. Esophageal or gastric motility disorders may require endoscopic capsule transport or application of prokinetics if the real-time viewer proofs delayed transit. In pregnant women, VCE should be restricted to urgent cases where diagnosis cannot be postponed after delivery, as data on safety are missing. There is theoretical and clinical evidence that patients with implanted cardiac devices such as a pacemaker, cardioverters or left heart assist devices, can safely undergo VCE in spite of still existing contraindication by manufacturers. Children from the age of 2 years have safely undergone VCE. Although video capsules are not proven safe with magnetic resonance imaging (MRI), first single cases of patients incidentally undergoing MRI with an incorporated capsule have been reported, showing susceptibility artifacts but no signs of clinical harm. PMID:28018097

  8. Future ATM Concepts Evaluation Tool (FACET) Interface Control Document

    NASA Technical Reports Server (NTRS)

    Grabbe, Shon R.

    2017-01-01

    This Interface Control Document (ICD) documents the airspace adaptation and air traffic inputs of NASA's Future ATM Concepts and Evaluation Tool (FACET). Its intended audience is the project manager, project team, development team, and stakeholders interested in interfacing with the system. FACET equips Air Traffic Management (ATM) researchers and service providers with a way to explore, develop and evaluate advanced air transportation concepts before they are field-tested and eventually deployed. FACET is a flexible software tool that is capable of quickly generating and analyzing thousands of aircraft trajectories. It provides researchers with a simulation environment for preliminary testing of advanced ATM concepts. Using aircraft performance profiles, airspace models, weather data, and flight schedules, the tool models trajectories for the climb, cruise, and descent phases of flight for each type of aircraft. An advanced graphical interface displays traffic patterns in two and three dimensions, under various current and projected conditions for specific airspace regions or over the entire continental United States. The system is able to simulate a full day's dynamic national airspace system (NAS) operations, model system uncertainty, measure the impact of different decision-makers in the NAS, and provide analysis of the results in graphical form, including sector, airport, fix, and airway usage statistics. NASA researchers test and analyze the system-wide impact of new traffic flow management algorithms under anticipated air traffic growth projections on the nation's air traffic system. In addition to modeling the airspace system for NASA research, FACET has also successfully transitioned into a valuable tool for operational use. Federal Aviation Administration (FAA) traffic flow managers and commercial airline dispatchers have used FACET technology for real-time operations planning. FACET integrates live air traffic data from FAA radar systems and weather data

  9. 21 CFR 520.1660b - Oxytetracycline hydrochloride capsules.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Oxytetracycline hydrochloride capsules. 520.1660b... Oxytetracycline hydrochloride capsules. (a) Specifications. The drug is in capsule form with each capsule containing 125 or 250 milligrams of oxytetracycline hydrochloride. Oxytetracycline is the antibiotic...

  10. A diffuse interface model of grain boundary faceting

    NASA Astrophysics Data System (ADS)

    Abdeljawad, Fadi; Medlin, Douglas; Zimmerman, Jonathan; Hattar, Khalid; Foiles, Stephen

    Incorporating anisotropy into thermodynamic treatments of interfaces dates back to over a century ago. For a given orientation of two abutting grains in a pure metal, depressions in the grain boundary (GB) energy may exist as a function of GB inclination, defined by the plane normal. Therefore, an initially flat GB may facet resulting in a hill-and-valley structure. Herein, we present a diffuse interface model of GB faceting that is capable of capturing anisotropic GB energies and mobilities, and accounting for the excess energy due to facet junctions and their non-local interactions. The hallmark of our approach is the ability to independently examine the role of each of the interface properties on the faceting behavior. As a demonstration, we consider the Σ 5 < 001 > tilt GB in iron, where faceting along the { 310 } and { 210 } planes was experimentally observed. Linear stability analysis and numerical examples highlight the role of junction energy and associated non-local interactions on the resulting facet length scales. On the whole, our modeling approach provides a general framework to examine the spatio-temporal evolution of highly anisotropic GBs in polycrystalline metals. Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. DOE's National Nuclear Security Administration under Contract DE-AC04-94AL85000.

  11. Facet-Dependent Cr(VI) Adsorption of Hematite Nanocrystals.

    PubMed

    Huang, Xiaopeng; Hou, Xiaojing; Song, Fahui; Zhao, Jincai; Zhang, Lizhi

    2016-02-16

    In this study, the adsorption process of Cr(VI) on the hematite facets was systematically investigated with synchrotron-based Cr K-edge extended X-ray absorption fine structure (EXAFS) spectroscopy, in situ attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectroscopy, density-functional theory calculation, and surface complexation models. Structural model fitting of EXAFS spectroscopy suggested that the interatomic distances of Cr-Fe were, respectively, 3.61 Å for the chromate coordinated hematite nanoplates with exposed {001} facets, 3.60 and 3.30 Å for the chromate coordinated hematite nanorods with exposed {001} and {110} facets, which were characteristic of inner-sphere complexation. In situ ATR-FTIR spectroscopy analysis confirmed the presence of two inner-sphere surface complexes with C3ν and C2ν symmetry, while the C3ν and C2ν species were assigned to monodentate and bidentate inner-sphere surface complexes with average Cr-Fe interatomic distances of 3.60 and 3.30 Å, respectively. On the basis of these experimental and theoretical results, we concluded that HCrO4(-) as dominated Cr(VI) species was adsorbed on {001} and {110} facets in inner-sphere monodentate mononuclear and bidentate binuclear configurations, respectively. Moreover, the Cr(VI) adsorption performance of hematite facets was strongly dependent on the chromate complexes formed on the hematite facets.

  12. A diffuse interface model of grain boundary faceting

    NASA Astrophysics Data System (ADS)

    Abdeljawad, F.; Medlin, D. L.; Zimmerman, J. A.; Hattar, K.; Foiles, S. M.

    2016-06-01

    Interfaces, free or internal, greatly influence the physical properties and stability of materials microstructures. Of particular interest are the processes that occur due to anisotropic interfacial properties. In the case of grain boundaries (GBs) in metals, several experimental observations revealed that an initially flat GB may facet into hill-and-valley structures with well defined planes and corners/edges connecting them. Herein, we present a diffuse interface model that is capable of accounting for strongly anisotropic GB properties and capturing the formation of hill-and-valley morphologies. The hallmark of our approach is the ability to independently examine the various factors affecting GB faceting and subsequent facet coarsening. More specifically, our formulation incorporates higher order expansions to account for the excess energy due to facet junctions and their non-local interactions. As a demonstration of the modeling capability, we consider the Σ5 <001 > tilt GB in body-centered-cubic iron, where faceting along the {210} and {310} planes was experimentally observed. Atomistic calculations were utilized to determine the inclination-dependent GB energy, which was then used as an input in our model. Linear stability analysis and simulation results highlight the role of junction energy and associated non-local interactions on the resulting facet length scales. Broadly speaking, our modeling approach provides a general framework to examine the microstructural stability of polycrystalline systems with highly anisotropic GBs.

  13. Basic ammonothermal GaN growth in molybdenum capsules

    NASA Astrophysics Data System (ADS)

    Pimputkar, S.; Speck, J. S.; Nakamura, S.

    2016-12-01

    Single crystal, bulk gallium nitride (GaN) crystals were grown using the basic ammonothermal method in a high purity growth environment created using a non-hermetically sealed molybdenum (Mo) capsule and compared to growths performed in a similarly designed silver (Ag) capsule and capsule-free René 41 autoclave. Secondary ion mass spectrometry (SIMS) analysis revealed transition metal free (<1×1017 cm-3) GaN crystals. Anomalously low oxygen concentrations ((2-6)×1018 cm-3) were measured in a {0001} seeded crystal boule grown using a Mo capsule, despite higher source material oxygen concentrations ((1-5)×1019 cm-3) suggesting that molybdenum (or molybdenum nitrides) may act to getter oxygen under certain conditions. Total system pressure profiles from growth runs in a Mo capsule system were comparable to those without a capsule, with pressures peaking within 2 days and slowly decaying due to hydrogen diffusional losses. Measured Mo capsule GaN growth rates were comparable to un-optimized growth rates in capsule-free systems and appreciably slower than in Ag-capsule systems. Crystal quality replicated that of the GaN seed crystals for all capsule conditions, with high quality growth occurring on the (0001) Ga-face. Optical absorption and impurity concentration characterization suggests reduced concentrations of hydrogenated gallium vacancies (VGa-Hx).

  14. Lumbar facet anatomy changes in spondylolysis: a comparative skeletal study

    PubMed Central

    Dar, Gali; Peleg, Smadar; Steinberg, Nili; Alperovitch-Najenson, Dvora; Salame, Khalil; Hershkovitz, Israel

    2007-01-01

    Opinions differ as to the exact mechanism responsible for spondylolysis (SP) and whether individuals with specific morphological characteristics of the lumbar vertebral neural arch are predisposed to SP. The aim of our study was to reveal the association between SP and the architecture of lumbar articular facets and the inter-facet region. Methods: Using a Microscribe three-dimensional apparatus (Immersion Co., San Jose, CA, USA), length, width and depth of all articular facets and all inter-facet distances in the lumbar spine (L1–L5) were measured. From the Hamann-Todd Human Osteological Collection (Cleveland Museum of Natural History, OH, USA) 120 normal male skeletons with lumbar spines in the control group and 115 with bilateral SP at L5 were selected. Analysis of variance was employed to examine the differences between spondylolytic and normal spines. Results: Three profound differences between SP and the norm appeared: (1) in individuals with SP, the size and shape of L4’s neural arch had significantly greater inter-facet widths, significantly shorter inter-facet heights and significantly shorter and narrower articular facets; (2) only in the L4 vertebra in individuals with SP was the inferior inter-facet width greater in size than the superior inter-facet width of the vertebra below (L5) (38.7 mm versus 40 mm); (3) in all lumbar vertebrae, the right inferior articular facets in individuals with SP were flatter compared to the control group. Conclusions: Individuals with L4 “SP” characteristics are at a greater risk of developing fatigue fractures in the form of spondylolysis at L5. PMID:17440753

  15. Foundations of reusable and interoperable facet models using category theory

    PubMed Central

    2016-01-01

    Faceted browsing has become ubiquitous with modern digital libraries and online search engines, yet the process is still difficult to abstractly model in a manner that supports the development of interoperable and reusable interfaces. We propose category theory as a theoretical foundation for faceted browsing and demonstrate how the interactive process can be mathematically abstracted. Existing efforts in facet modeling are based upon set theory, formal concept analysis, and light-weight ontologies, but in many regards, they are implementations of faceted browsing rather than a specification of the basic, underlying structures and interactions. We will demonstrate that category theory allows us to specify faceted objects and study the relationships and interactions within a faceted browsing system. Resulting implementations can then be constructed through a category-theoretic lens using these models, allowing abstract comparison and communication that naturally support interoperability and reuse. PMID:27942248

  16. Initial experimental evaluation of wireless capsule endoscopes in the bladder: implications for capsule cystoscopy.

    PubMed

    Gettman, Matthew T; Swain, Paul

    2009-05-01

    Cystoscopy remains one of the most important diagnostic procedures for the lower urinary tract. Wireless capsule endoscopy was introduced in the 1990s but use to date is limited to gastroenterology. We evaluated the feasibility in the pig model of using wireless capsule endoscopes (WCEs) for cystoscopy. Experimental evaluation of capsule cystoscopy was performed in a 50-kg farm pig. The capsule was deployed into the bladder through a custom access sheath. Images were continuously transmitted at a rate of four frames per second to a laptop computer and processed using proprietary software. Manipulation of the WCE within the bladder was performed using a set protocol. The animal was then euthanized and gross inspection was performed. We measured the ability to deploy and manipulate the capsule within the bladder. Feasibility of capturing and retrieving images in real time was also assessed. The WCE was efficiently deployed and manipulated within the bladder passively and with the use of external magnets. The entire bladder mucosa was visualized. Real-time image transmission and capture were successful. No complications were seen during capsule cystoscopy. Minor urethral bleeding was observed after the experiment, likely related to placement of the access sheath required for deployment of the WCE. Limitations are that the evaluation of WCE was performed in the pig model, in only one female animal, using a nonsurvival approach. Furthermore, the study was not designed to differentiate normal from abnormal mucosal findings and focused solely on inspection of the bladder. This report suggests that cystoscopy with a WCE is feasible. With this device, all aspects of the bladder mucosa could be visualized, and ongoing technologic and procedural developments are warranted for this new approach.

  17. Anterior capsule relaxing incisions with neodymium:YAG laser for patients at high-risk for anterior capsule contraction.

    PubMed

    Hayashi, Ken; Yoshida, Motoaki; Hirata, Akira; Hayashi, Hideyuki

    2011-01-01

    To examine the effect of anterior capsule relaxing incisions created with a neodymium:YAG (Nd:YAG) laser on prevention of anterior capsule contraction after cataract surgery in high-risk patients. Hayashi Eye Hospital, Fukuoka, Japan. Randomized masked clinical trials. Patients at high risk for anterior capsule contraction had anterior capsule relaxing incisions in either eye 3 days postoperatively. The anterior capsule opening was measured using a Scheimpflug videophotography system (EAS-1000) immediately and 1, 3, and 6 months after capsulotomy, and the percentage reduction in area was calculated. The degree of intraocular lens (IOL) decentration and tilt, posterior capsule opacification (PCO), and other complications were also assessed. Of the 84 patients included, 30 had primary angle closure, 28 had pseudoexfoliation, and 26 had diabetic retinopathy. There was no significant difference in the mean opening area between fellow eyes at baseline. In patients with primary angle closure, the area was significantly greater and the percentage reduction in area was significantly less in the capsulotomy group than in the no-capsulotomy group (P≤.0428). In patients with pseudoexfoliation or diabetic retinopathy, the percentage reduction was significantly less in the capsulotomy group than in the no-capsulotomy group (P≤.0493), although there was no significant difference in area. No significant difference was found in IOL decentration or tilt, PCO, or incidence of other complications. Neodymium:YAG laser anterior capsule relaxing incisions in the early period after cataract surgery were effective in preventing anterior capsule contraction in high-risk patients and had no adverse effects. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2010 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  18. Preservation of the articular capsule and short lateral rotator in direct anterior approach to total hip arthroplasty.

    PubMed

    Kanda, Akio; Kaneko, Kazuo; Obayashi, Osamu; Mogami, Atsuhiko; Morohashi, Itaru

    2018-03-09

    In total hip arthroplasty via a direct anterior approach, the femur must be elevated at the time of femoral implant placement. For adequate elevation, division of the posterior soft tissues is necessary. However, if we damage and separate the posterior muscle tissue, we lose the benefits of the intermuscular approach. Furthermore, damage to the posterior soft tissue can result in posterior dislocation. We investigate that protecting the posterior soft tissue increases the joint stability in the early postoperative period and results in a lower dislocation rate. We evaluated muscle strength recovery by measuring the maximum width of the internal obturator muscle on CT images (GE-Healthcare Discovery CT 750HD). We compared the maximum width of the muscle belly preoperatively versus 10 days and 6 months postoperatively. As clinical evaluations, we also investigated the range of motion of the hip joint, hip joint function based on the Japanese Orthopaedic Association hip score (JOA score), and the dislocation rate 6 months after surgery. The width of the internal obturator muscle increased significantly from 15.1 ± 3.1 mm before surgery to 16.4 ± 2.8 mm 6 months after surgery. The JOA score improved significantly from 50.8 ± 15.1 points to 95.6 ± 7.6 points. No dislocations occurred in this study. We cut only the posterosuperior articular capsule and protected the internal obturator muscle to preserve muscle strength. We repaired the entire posterosuperior and anterior articular capsule. These treatments increase joint stability in the early postoperative period, thus reducing the dislocation rate. Therapeutic, Level IV.

  19. Identification of Genes That Interact With Drosophila liquid facets

    PubMed Central

    Eun, Suk Ho; Lea, Kristi; Overstreet, Erin; Stevens, Samuel; Lee, Ji-Hoon; Fischer, Janice A.

    2007-01-01

    We have performed mutagenesis screens of the Drosophila X chromosome and the autosomes for dominant enhancers of the rough eye resulting from overexpression of liquid facets. The liquid facets gene encodes the homolog of vertebrate endocytic Epsin, an endocytic adapter protein. In Drosophila, Liquid facets is a core component of the Notch signaling pathway required in the signaling cells for ligand endocytosis and signaling. Why ligand internalization by the signaling cells is essential for signaling is a mystery. The requirement for Liquid facets is a hint at the answer, and the genes identified in this screen provide further clues. Mutant alleles of clathrin heavy chain, Rala, split ends, and auxilin were identified as enhancers. We describe the mutant alleles and mutant phenotypes of Rala and aux. We discuss the relevance of all of these genetic interactions to the function of Liquid facets in Notch signaling. PMID:17179082

  20. Reinforcing effects of caffeine in coffee and capsules.

    PubMed

    Griffiths, R R; Bigelow, G E; Liebson, I A

    1989-09-01

    In a residential research ward the reinforcing and subjective effects of caffeine were studied under double-blind conditions in volunteer subjects with histories of heavy coffee drinking. In Experiment 1, 6 subjects had 13 opportunities each day to self-administer either a caffeine (100 mg) or a placebo capsule for periods of 14 to 61 days. All subjects developed a clear preference for caffeine, with intake of caffeine becoming relatively stable after preference had been attained. Preference for caffeine was demonstrated whether or not preference testing was preceded by a period of 10 to 37 days of caffeine abstinence, suggesting that a recent history of heavy caffeine intake (tolerance/dependence) was not a necessary condition for caffeine to function as a reinforcer. In Experiment 2, 6 subjects had 10 opportunities each day to self-administer a cup of coffee or (on different days) a capsule, dependent upon completing a work requirement that progressively increased and then decreased over days. Each day, one of four conditions was studied: caffeinated coffee (100 mg/cup), decaffeinated coffee, caffeine capsules (100 mg/capsule), or placebo capsules. Caffeinated coffee maintained the most self-administration, significantly higher than decaffeinated coffee and placebo capsules but not different from caffeine capsules. Both decaffeinated coffee and caffeine capsules were significantly higher than placebo capsules but not different from each other. In both experiments, subject ratings of "linking" of coffee or capsules covaried with the self-administration measures. These experiments provide the clearest demonstrations to date of the reinforcing effects of caffeine in capsules and in coffee.

  1. Reinforcing effects of caffeine in coffee and capsules.

    PubMed Central

    Griffiths, R R; Bigelow, G E; Liebson, I A

    1989-01-01

    In a residential research ward the reinforcing and subjective effects of caffeine were studied under double-blind conditions in volunteer subjects with histories of heavy coffee drinking. In Experiment 1, 6 subjects had 13 opportunities each day to self-administer either a caffeine (100 mg) or a placebo capsule for periods of 14 to 61 days. All subjects developed a clear preference for caffeine, with intake of caffeine becoming relatively stable after preference had been attained. Preference for caffeine was demonstrated whether or not preference testing was preceded by a period of 10 to 37 days of caffeine abstinence, suggesting that a recent history of heavy caffeine intake (tolerance/dependence) was not a necessary condition for caffeine to function as a reinforcer. In Experiment 2, 6 subjects had 10 opportunities each day to self-administer a cup of coffee or (on different days) a capsule, dependent upon completing a work requirement that progressively increased and then decreased over days. Each day, one of four conditions was studied: caffeinated coffee (100 mg/cup), decaffeinated coffee, caffeine capsules (100 mg/capsule), or placebo capsules. Caffeinated coffee maintained the most self-administration, significantly higher than decaffeinated coffee and placebo capsules but not different from caffeine capsules. Both decaffeinated coffee and caffeine capsules were significantly higher than placebo capsules but not different from each other. In both experiments, subject ratings of "linking" of coffee or capsules covaried with the self-administration measures. These experiments provide the clearest demonstrations to date of the reinforcing effects of caffeine in capsules and in coffee. PMID:2794839

  2. Subtalar joint stress imaging with tomosynthesis.

    PubMed

    Teramoto, Atsushi; Watanabe, Kota; Takashima, Hiroyuki; Yamashita, Toshihiko

    2014-06-01

    The purpose of this study was to perform stress imaging of hindfoot inversion and eversion using tomosynthesis and to assess the subtalar joint range of motion (ROM) of healthy subjects. The subjects were 15 healthy volunteers with a mean age of 29.1 years. Coronal tomosynthesis stress imaging of the subtalar joint was performed in a total of 30 left and right ankles. A Telos stress device was used for the stress load, and the load was 150 N for both inversion and eversion. Tomographic images in which the posterior talocalcaneal joint could be confirmed on the neutral position images were used in measurements. The angle of the intersection formed by a line through the lateral articular facet of the posterior talocalcaneal joint and a line through the surface of the trochlea of the talus was measured. The mean change in the angle of the calcaneus with respect to the talus was 10.3 ± 4.8° with inversion stress and 5.0 ± 3.8° with eversion stress from the neutral position. The result was a clearer depiction of the subtalar joint, and inversion and eversion ROM of the subtalar joint was shown to be about 15° in healthy subjects. Diagnostic, Level IV.

  3. Sensor capsule for diagnosis of gastric disorders

    NASA Technical Reports Server (NTRS)

    Holen, J. T.

    1972-01-01

    Motility and pH sensor capsule is developed to monitor gastric acidity, pressure, and temperature. Capsule does not interfere with digestion. Sensor is capsule which includes pH electrode, Pitran pressure transducer, and thermistor temperature sensor all potted in epoxy and enclosed in high density polyethylene sheath.

  4. Capsule endoscopy: no longer limited to the small bowel.

    PubMed

    Niv, Yaron

    2010-03-01

    Capsule endoscopy is the latest evolution in gastrointestinal endoscopy and the first to enable complete investigation of the small bowel. Recent new developments in the field of capsule endoscopy include the esophageal capsule (Pilcam ESO) and the colonic capsule (PillCam Colon). esophageal and colonic capsules have two heads with two lenses and cameras. The new capsules have the capability of taking more frames from both sides. The indications for the esophageal capsule examination are diagnosis and follow-up of Barrett's esophagus and esophageal varices. The colonic capsule can be used for colorectal cancer screening and for incomplete colonoscopy. Regarding other new technologies, continuous quality control is needed for the performance, appropriateness of the indications, diagnostic yield, procedure-specific outcome assessment, and cost-effectiveness.

  5. Structure and Composition of the Bacillus anthracis Capsule

    PubMed Central

    Avakyan, A. A.; Katz, L. N.; Levina, K. N.; Pavlova, I. B.

    1965-01-01

    Avakyan, A. A. (Academy of Medical Sciences, Moscow, USSR), L. N. Katz, K. N. Levina, and I. B. Pavlova. Structure and composition of the Bacillus anthracis capsule. J. Bacteriol. 90:1082–1095. 1965.—Observations by various methods of light microscopy (phase contrast, dark-field, and fluorescence) revealed the complex structure of the Bacillus anthracis capsule, which changes regularly during the growth cycle of the culture. Special cytological methods of staining the capsule made it possible to study its fine structure, which is not revealed by negative staining with India ink. For example, the capsule shows a membranelike outline, fine transverse lines, and interruptions and transverse septa traversing the entire capsule. By using cytochemical methods, it was found that the capsule has a stratified structure and that the various layers of the capsule differ as to the value of the isoelectric point, metachromatic ability, sensitivity to various enzymes, and, consequently, chemical composition. It was thus shown that the membranelike outline of the capsule consists of peptides and neutral mucopolysaccharides. The middle part of the capsule consists of a complex of substances of both polysaccharide and protein nature, and the inner part consists of acid mucopolysaccharides. Observation of the capsular forms of B. anthracis by means of an electron microscope revealed differences in the osmiophilia and submicroscopic structure of the membranelike outline and the middle and inner parts of the capsule. Immunochemical studies conducted by the fluorescent-antibody method revealed localization of antigens in different parts of the capsule, and made it possible to differentiate the capsular antigens according to their serum-staining ability and according of their relations to enzymes, i.e., their chemical composition. This paper concerns the possibility of studying the fine structure of bacterial capsules in fixed preparations, and the differences and similarities of

  6. A New Family of Capsule Polymerases Generates Teichoic Acid-Like Capsule Polymers in Gram-Negative Pathogens.

    PubMed

    Litschko, Christa; Oldrini, Davide; Budde, Insa; Berger, Monika; Meens, Jochen; Gerardy-Schahn, Rita; Berti, Francesco; Schubert, Mario; Fiebig, Timm

    2018-05-29

    Group 2 capsule polymers represent crucial virulence factors of Gram-negative pathogenic bacteria. They are synthesized by enzymes called capsule polymerases. In this report, we describe a new family of polymerases that combine glycosyltransferase and hexose- and polyol-phosphate transferase activity to generate complex poly(oligosaccharide phosphate) and poly(glycosylpolyol phosphate) polymers, the latter of which display similarity to wall teichoic acid (WTA), a cell wall component of Gram-positive bacteria. Using modeling and multiple-sequence alignment, we showed homology between the predicted polymerase domains and WTA type I biosynthesis enzymes, creating a link between Gram-negative and Gram-positive cell wall biosynthesis processes. The polymerases of the new family are highly abundant and found in a variety of capsule-expressing pathogens such as Neisseria meningitidis , Actinobacillus pleuropneumoniae , Haemophilus influenzae , Bibersteinia trehalosi , and Escherichia coli with both human and animal hosts. Five representative candidates were purified, their activities were confirmed using nuclear magnetic resonance (NMR) spectroscopy, and their predicted folds were validated by site-directed mutagenesis. IMPORTANCE Bacterial capsules play an important role in the interaction between a pathogen and the immune system of its host. During the last decade, capsule polymerases have become attractive tools for the production of capsule polymers applied as antigens in glycoconjugate vaccine formulations. Conventional production of glycoconjugate vaccines requires the cultivation of the pathogen and thus the highest biosafety standards, leading to tremendous costs. With regard to animal husbandry, where vaccines could avoid the extensive use of antibiotics, conventional production is not sufficiently cost-effective. In contrast, enzymatic synthesis of capsule polymers is pathogen-free and fast, offers high stereo- and regioselectivity, and works with high efficacy

  7. Oxygen fugacity and piston cylinder capsule assemblies

    NASA Astrophysics Data System (ADS)

    Jakobsson, S.

    2011-12-01

    A double capsule assembly designed to control oxygen fugacity in piston cylinder experiments has been tested at 1200 °C and 10 kbar. The assembly consists of an outer Pt-capsule containing a solid buffer (Ni-NiO or Co-CoO plus H2O) and an inner AuPd-capsule containing the sample, H2O and a Pt-wire. To prevent direct contact with the buffer phases the AuPd-capsule is embedded in finely ground Al2O3 along with some coarser, fractured Al2O3 facilitating fluid inclusion formation. No water loss is observed in the sample even after 48 hrs but a slight increase in water content is observed in longer duration runs due to oxygen and hydrogen diffusion into the AuPd-capsule. Carbon from the furnace also diffuses through the outer Pt-capsule but reacts with H2O in the outer capsule to form CO2 and never reaches the inner capsule. Oxygen fugacity of runs in equilibrium with the Ni-NiO and Co-CoO buffers was measured by analyzing the Fe content of the Pt-wire in the sample1 and by analyzing Fe dissolved in the AuPd capsule2. The second method gives values that are in good agreement with established buffer whereas results from the first method are one half to one log units higher than the established values. References 1. E. Medard, C. A. McCammon, J. A. Barr, T. L. Grove, Am. Mineral. 93, 1838 (2008). 2. J. Barr, T. Grove, Contrib. Mineral. Petrol. 160, 631 (2010)

  8. Vortex rings from Sphagnum moss capsules

    NASA Astrophysics Data System (ADS)

    Whitaker, Dwight; Strassman, Sam; Cha, Jung; Chang, Emily; Guo, Xinyi; Edwards, Joan

    2010-11-01

    The capsules of Sphagnum moss use vortex rings to disperse spores to suitable habitats many kilometers away. Vortex rings are created by the sudden release of pressurized air when the capsule ruptures, and are an efficient way to carry the small spores with low terminal velocities to heights where they can be carried by turbulent wind currents. We will present our computational model of these explosions, which are carried out using a 2-D large eddy simulation (LES) on FLUENT. Our simulations can reproduce the observed motion of the spore clouds observed from moss capsules with high-speed videos, and we will discuss the roles of bursting pressure, cap mass, and capsule morphology on the formation and quality of vortex rings created by this plant.

  9. Polyelectrolyte multilayer capsules as vehicles with tunable permeability.

    PubMed

    Antipov, Alexei A; Sukhorukov, Gleb B

    2004-11-29

    This review is devoted to a novel type of polymer micro- and nanocapsules. The shell of the capsule is fabricated by alternate adsorption of oppositely charged polyelectrolytes (PEs) onto the surface of colloidal particles. Cores of different nature (organic or inorganic) with size varied from 0.1 to 10 mum can be used for templating such PE capsules. The shell thickness can be tuned in nanometer range by assembling of defined number of PE layers. The permeability of capsules depends on the pH, ionic strength, solvent, polymer composition, and shell thickness; it can be controlled and varied over wide range of substances regarding their molecular weight and charge. Including functional polymers into capsule wall, such as weak PEs or thermosensitive polymers, makes the capsule permeability sensitive to correspondent external stimuli. Permeability of the capsules is of essential interest in diverse areas related to exploitation of systems with controlled and sustained release properties. The envisaged applications of such capsules/vesicles cover biotechnology, medicine, catalysis, food industry, etc.

  10. Cell cycle constraints on capsulation and bacteriophage susceptibility.

    PubMed

    Ardissone, Silvia; Fumeaux, Coralie; Bergé, Matthieu; Beaussart, Audrey; Théraulaz, Laurence; Radhakrishnan, Sunish Kumar; Dufrêne, Yves F; Viollier, Patrick H

    2014-11-25

    Despite the crucial role of bacterial capsules in pathogenesis, it is still unknown if systemic cues such as the cell cycle can control capsule biogenesis. In this study, we show that the capsule of the synchronizable model bacterium Caulobacter crescentus is cell cycle regulated and we unearth a bacterial transglutaminase homolog, HvyA, as restriction factor that prevents capsulation in G1-phase cells. This capsule protects cells from infection by a generalized transducing Caulobacter phage (φCr30), and the loss of HvyA confers insensitivity towards φCr30. Control of capsulation during the cell cycle could serve as a simple means to prevent steric hindrance of flagellar motility or to ensure that phage-mediated genetic exchange happens before the onset of DNA replication. Moreover, the multi-layered regulatory circuitry directing HvyA expression to G1-phase is conserved during evolution, and HvyA orthologues from related Sinorhizobia can prevent capsulation in Caulobacter, indicating that alpha-proteobacteria have retained HvyA activity.

  11. 21 CFR 872.3110 - Dental amalgam capsule.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Dental amalgam capsule. 872.3110 Section 872.3110...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3110 Dental amalgam capsule. (a) Identification. A dental amalgam capsule is a container device in which silver alloy is intended to be mixed with mercury...

  12. 21 CFR 872.3110 - Dental amalgam capsule.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Dental amalgam capsule. 872.3110 Section 872.3110...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3110 Dental amalgam capsule. (a) Identification. A dental amalgam capsule is a container device in which silver alloy is intended to be mixed with mercury...

  13. 21 CFR 872.3110 - Dental amalgam capsule.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Dental amalgam capsule. 872.3110 Section 872.3110...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3110 Dental amalgam capsule. (a) Identification. A dental amalgam capsule is a container device in which silver alloy is intended to be mixed with mercury...

  14. 21 CFR 872.3110 - Dental amalgam capsule.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Dental amalgam capsule. 872.3110 Section 872.3110...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3110 Dental amalgam capsule. (a) Identification. A dental amalgam capsule is a container device in which silver alloy is intended to be mixed with mercury...

  15. 21 CFR 872.3110 - Dental amalgam capsule.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Dental amalgam capsule. 872.3110 Section 872.3110...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3110 Dental amalgam capsule. (a) Identification. A dental amalgam capsule is a container device in which silver alloy is intended to be mixed with mercury...

  16. Biomimetic/Bioinspired Design of Enzyme@capsule Nano/Microsystems.

    PubMed

    Shi, J; Jiang, Y; Zhang, S; Yang, D; Jiang, Z

    2016-01-01

    Enzyme@capsule nano/microsystems, which refer to the enzyme-immobilized capsules, have received tremendous interest owing to the combination of the high catalytic activities of encapsulated enzymes and the hierarchical structure of the capsule. The preparation of capsules and simultaneous encapsulation of enzymes is recognized as the core process for the rational design and construction of enzyme@capsule nano/microsystems. The strategy used has three major steps: (a) generation of the templates, (b) surface coating on the templates, and (c) removal of the templates, and it has been proven to be effective and versatile for the construction of enzyme@capsule nano/microsystems. Several conventional methods, including layer-by-layer assembly of polyelectrolytes, liquid crystalline templating method, etc., were used to design and construct enzyme@capsule nano/microsystems, but these have two major drawbacks. One is the low mechanical stability of the systems and the second is the harsh conditions used in the construction process. Learning from nature, several biomimetic/bioinspired methods such as biomineralization, biomimetic/bioinspired adhesion, and their combination have been exploited for the construction of enzyme@capsule nano/microsystems. In this chapter, we will present a general protocol for the construction of enzyme@capsule nano/microsystems using the latter approach. Some suggestions for improved design, construction, and characterization will also be presented with detailed procedures for specific examples. © 2016 Elsevier Inc. All rights reserved.

  17. LOFAR facet callibration

    DOE PAGES

    Weeren, R. J. van; Williams, W. L.; Hardcastle, M. J.; ...

    2016-03-07

    LOFAR, the Low-Frequency Array, is a powerful new radio telescope operating between 10 and 240 MHz. LOFAR allows detailed sensitive high-resolution studies of the low-frequency radio sky. At the same time LOFAR also provides excellent short baseline coverage to map di use extended emission. However, producing high-quality deep images is challenging due to the presence of direction dependent calibration errors, caused by imperfect knowledge of the station beam shapes and the ionosphere. Furthermore, the large data volume and presence of station clock errors present additional di culties. In this paper we present a new calibration scheme, which we name facetmore » calibration, to obtain deep high-resolution LOFAR High Band Antenna images using the Dutch part of the array. This scheme solves and corrects the direction dependent errors in a number of facets that cover the observed eld of view. Facet calibration provides close to thermal noise limited images for a typical 8 hr observing run at ~5'' resolution, meeting the speci cations of the LOFAR Tier-1 northern survey.« less

  18. 3D Printed Programmable Release Capsules.

    PubMed

    Gupta, Maneesh K; Meng, Fanben; Johnson, Blake N; Kong, Yong Lin; Tian, Limei; Yeh, Yao-Wen; Masters, Nina; Singamaneni, Srikanth; McAlpine, Michael C

    2015-08-12

    The development of methods for achieving precise spatiotemporal control over chemical and biomolecular gradients could enable significant advances in areas such as synthetic tissue engineering, biotic-abiotic interfaces, and bionanotechnology. Living organisms guide tissue development through highly orchestrated gradients of biomolecules that direct cell growth, migration, and differentiation. While numerous methods have been developed to manipulate and implement biomolecular gradients, integrating gradients into multiplexed, three-dimensional (3D) matrices remains a critical challenge. Here we present a method to 3D print stimuli-responsive core/shell capsules for programmable release of multiplexed gradients within hydrogel matrices. These capsules are composed of an aqueous core, which can be formulated to maintain the activity of payload biomolecules, and a poly(lactic-co-glycolic) acid (PLGA, an FDA approved polymer) shell. Importantly, the shell can be loaded with plasmonic gold nanorods (AuNRs), which permits selective rupturing of the capsule when irradiated with a laser wavelength specifically determined by the lengths of the nanorods. This precise control over space, time, and selectivity allows for the ability to pattern 2D and 3D multiplexed arrays of enzyme-loaded capsules along with tunable laser-triggered rupture and release of active enzymes into a hydrogel ambient. The advantages of this 3D printing-based method include (1) highly monodisperse capsules, (2) efficient encapsulation of biomolecular payloads, (3) precise spatial patterning of capsule arrays, (4) "on the fly" programmable reconfiguration of gradients, and (5) versatility for incorporation in hierarchical architectures. Indeed, 3D printing of programmable release capsules may represent a powerful new tool to enable spatiotemporal control over biomolecular gradients.

  19. Characteristics of patients with a retained wireless capsule endoscope (WCE) necessitating laparotomy for removal of the capsule.

    PubMed

    Purdy, Martin; Heikkinen, Markku; Juvonen, Petri; Voutilainen, Markku; Eskelinen, Matti

    2011-01-01

    A capsule endoscope is a wireless miniature camera used to take images of the small bowel mucosa. Retention of the wireless capsule endoscope (WCE), defined as at least two weeks' retention or an obstruction demanding removal by laparotomy, is the main and practically only complication of the procedure. The aim of this study was to evaluate the characteristics of patients with a retained WCE necessitating laparotomy for removal of the capsule or capsule fragments. The medical records of 555 patients who had undergone the WCE procedure over a 7-year period (2002-2008) were reviewed. The indications for the WCE procedure were, obscure gastrointestinal bleeding, Crohn's disease, abdominal pain and suspicion of malignancy. A retained WCE requiring operative treatment was found in 10 cases (in nine patients, twice in one patient). The WCE retention frequency of 1.8% (10/555) equalled that in the literature. The retention rate of WCE capsules is low and routine examination of the small bowel with MRI or CT is not necessary before WCE. These examinations were enable to predict WCE retention according to our results.

  20. Capsules made from prefabricated thin films

    NASA Astrophysics Data System (ADS)

    Amstad, Esther

    2018-02-01

    Capsules are composed of a core, typically a liquid containing active substances, and a surrounding shell. They are used to delay the degradation of active ingredients, protect them from reacting or interacting with substances contained in the surrounding shell, or to prevent premature consumption of encapsulants (1, 2). The performance of capsules is often determined by their permeability toward encapsulants and stability against rupture; these parameters can be adjusted with the composition, structure, and thickness of the shell (3, 4). Mechanically robust capsules with a minimal permeability even toward low molecular weight substances often have rather thick shells (5). On page 775 of this issue, Kumar et al. (6) report an elegant process to fabricate capsules with very thin, rigid shells that display a low permeability even toward small encapsulants.

  1. Cervical facet oedema: prevalence, correlation to symptoms, and follow-up imaging.

    PubMed

    Nevalainen, M T; Foran, P J; Roedl, J B; Zoga, A C; Morrison, W B

    2016-06-01

    To evaluate the prevalence of cervical facet oedema in patients referred for magnetic resonance imaging (MRI) to investigate neck pain and/or radiculopathy, and to investigate whether there is a correlation between the presence of oedema and patients' symptoms. A retrospective report review of 1885 patients undergoing cervical spine MRI between July 2008 and June 2015 was performed. Exclusion criteria included acute trauma, surgery, neoplastic disease, or infection in the cervical spine. One hundred and seventy-three MRI studies with cervical facet oedema were evaluated by each of the two radiologists. In these patients, the grade of bone marrow oedema (BMO) and corresponding neuroforaminal narrowing at the cervical facets was assessed. Correlation with symptoms was performed based on pre-MRI questionnaire. The prevalence of cervical facet oedema was 9%; the most commonly affected levels were C3-4, C4-5, and C2-3. A total of 202 cervical facets were evaluated: mild BMO was seen in 35%, moderate in 41%, and severe in 24% of cases. Surrounding soft-tissue oedema was observed in 36%, 69%, and 92% of the BMO grades, respectively. The correlations between unilateral radiculopathy and ipsilateral facet BMO grades were 79%, 83%, and 73% (chi-square, p<0.001), respectively. Furthermore, neuroforaminal narrowing on the corresponding level was found in 35%, 38%, and 11% of cases, respectively. At follow-up imaging, facet oedema was most likely to remain unchanged or to decrease. The prevalence of cervical facet oedema is 9%. Cervical facet oedema is associated with ipsilateral radiculopathy. Neuroforaminal narrowing, however, is not associated with facet oedema. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  2. Physical-geometric optics method for large size faceted particles.

    PubMed

    Sun, Bingqiang; Yang, Ping; Kattawar, George W; Zhang, Xiaodong

    2017-10-02

    A new physical-geometric optics method is developed to compute the single-scattering properties of faceted particles. It incorporates a general absorption vector to accurately account for inhomogeneous wave effects, and subsequently yields the relevant analytical formulas effective and computationally efficient for absorptive scattering particles. A bundle of rays incident on a certain facet can be traced as a single beam. For a beam incident on multiple facets, a systematic beam-splitting technique based on computer graphics is used to split the original beam into several sub-beams so that each sub-beam is incident only on an individual facet. The new beam-splitting technique significantly reduces the computational burden. The present physical-geometric optics method can be generalized to arbitrary faceted particles with either convex or concave shapes and with a homogeneous or an inhomogeneous (e.g., a particle with a core) composition. The single-scattering properties of irregular convex homogeneous and inhomogeneous hexahedra are simulated and compared to their counterparts from two other methods including a numerically rigorous method.

  3. [Evaluation of nopal capsules in diabetes mellitus].

    PubMed

    Frati Munari, A C; Vera Lastra, O; Ariza Andraca, C R

    1992-01-01

    To find out if commercial capsules with dried nopal (prickle-pear cactus, Opuntia ficus indica may have a role in the management of diabetes mellitus, three experiments were performed: 30 capsules where given in fasting condition to 10 diabetic subjects and serum glucose was measured through out 3 hours; a control test was performed with 30 placebo capsules. OGTT with previous intake of 30 nopal or placebo capsules was performed in ten healthy individuals. In a crossover and single blinded study 14 diabetic patients withdrew the oral hypoglycemic treatment and received 10 nopal or placebo capsules t.i.d. during one week; serum glucose, cholesterol and tryglycerides levels were measured before and after each one-week period. Five healthy subjects were also studied in the same fashion. Opuntia capsules did not show acute hypoglycemic effect and did not influence OGTT. In diabetic patients serum glucose, cholesterol and tryglycerides levels did not change with Opuntia, but they increased with placebo (P < 0.01 glucose and cholesterol, P = NS triglycerides). In healthy individuals glycemia did not change with nopal, while cholesterol and triglycerides decreased (P < 0.01 vs. placebo). The intake of 30 Opuntia capsules daily in patients with diabetes mellitus had a discrete beneficial effect on glucose and cholesterol. However this dose is unpractical and at present it is not recommended in the management of diabetes mellitus.

  4. Emerging Issues and Future Developments in Capsule Endoscopy

    PubMed Central

    Slawinski, Piotr R.; Obstein, Keith L.; Valdastri, Pietro

    2015-01-01

    Capsule endoscopy (CE) has transformed from a research venture into a widely used clinical tool and the primary means for diagnosing small bowel pathology. These orally administered capsules traverse passively through the gastrointestinal tract via peristalsis and are used in the esophagus, stomach, small bowel, and colon. The primary focus of CE research in recent years has been enabling active CE manipulation and extension of the technology to therapeutic functionality; thus, widening the scope of the procedure. This review outlines clinical standards of the technology as well as recent advances in CE research. Clinical capsule applications are discussed with respect to each portion of the gastrointestinal tract. Promising research efforts are presented with an emphasis on enabling active capsule locomotion. The presented studies suggest, in particular, that the most viable solution for active capsule manipulation is actuation of a capsule via exterior permanent magnet held by a robot. Developing capsule procedures adhering to current healthcare standards, such as enabling a tool channel or irrigation in a therapeutic device, is a vital phase in the adaptation of CE in the clinical setting. PMID:26028956

  5. Cell cycle constraints on capsulation and bacteriophage susceptibility

    PubMed Central

    Ardissone, Silvia; Fumeaux, Coralie; Bergé, Matthieu; Beaussart, Audrey; Théraulaz, Laurence; Radhakrishnan, Sunish Kumar; Dufrêne, Yves F; Viollier, Patrick H

    2014-01-01

    Despite the crucial role of bacterial capsules in pathogenesis, it is still unknown if systemic cues such as the cell cycle can control capsule biogenesis. In this study, we show that the capsule of the synchronizable model bacterium Caulobacter crescentus is cell cycle regulated and we unearth a bacterial transglutaminase homolog, HvyA, as restriction factor that prevents capsulation in G1-phase cells. This capsule protects cells from infection by a generalized transducing Caulobacter phage (φCr30), and the loss of HvyA confers insensitivity towards φCr30. Control of capsulation during the cell cycle could serve as a simple means to prevent steric hindrance of flagellar motility or to ensure that phage-mediated genetic exchange happens before the onset of DNA replication. Moreover, the multi-layered regulatory circuitry directing HvyA expression to G1-phase is conserved during evolution, and HvyA orthologues from related Sinorhizobia can prevent capsulation in Caulobacter, indicating that alpha-proteobacteria have retained HvyA activity. DOI: http://dx.doi.org/10.7554/eLife.03587.001 PMID:25421297

  6. Capsule endoscopy—A mechatronics perspective

    NASA Astrophysics Data System (ADS)

    Lin, Lin; Rasouli, Mahdi; Kencana, Andy Prima; Tan, Su Lim; Wong, Kai Juan; Ho, Khek Yu; Phee, Soo Jay

    2011-03-01

    The recent advances in integrated circuit technology, wireless communication, and sensor technology have opened the door for development of miniature medical devices that can be used for enhanced monitoring and treatment of medical conditions. Wireless capsule endoscopy is one of such medical devices that has gained significant attention during the past few years. It is envisaged that future wireless capsule endoscopies replace traditional endoscopy procedures by providing advanced functionalities such as active locomotion, body fluid/tissue sampling, and drug delivery. Development of energy-efficient miniaturized actuation mechanisms is a key step toward achieving this goal. Here, we review some of the actuators that could be integrated into future wireless capsules and discuss the existing challenges.

  7. Large conservation gains possible for global biodiversity facets.

    PubMed

    Pollock, Laura J; Thuiller, Wilfried; Jetz, Walter

    2017-06-01

    Different facets of biodiversity other than species numbers are increasingly appreciated as critical for maintaining the function of ecosystems and their services to humans. While new international policy and assessment processes such as the Intergovernmental Science-Policy Platform on Biodiversity and Ecosystem Services (IPBES) recognize the importance of an increasingly global, quantitative and comprehensive approach to biodiversity protection, most insights are still focused on a single facet of biodiversity-species. Here we broaden the focus and provide an evaluation of how much of the world's species, functional and phylogenetic diversity of birds and mammals is currently protected and the scope for improvement. We show that the large existing gaps in the coverage for each facet of diversity could be remedied by a slight expansion of protected areas: an additional 5% of the land has the potential to more than triple the protected range of species or phylogenetic or functional units. Further, the same areas are often priorities for multiple diversity facets and for both taxa. However, we find that the choice of conservation strategy has a fundamental effect on outcomes. It is more difficult (that is, requires more land) to maximize basic representation of the global biodiversity pool than to maximize local diversity. Overall, species and phylogenetic priorities are more similar to each other than they are to functional priorities, and priorities for the different bird biodiversity facets are more similar than those of mammals. Our work shows that large gains in biodiversity protection are possible, while also highlighting the need to explicitly link desired conservation objectives and biodiversity metrics. We provide a framework and quantitative tools to advance these goals for multi-faceted biodiversity conservation.

  8. Large conservation gains possible for global biodiversity facets

    NASA Astrophysics Data System (ADS)

    Pollock, Laura J.; Thuiller, Wilfried; Jetz, Walter

    2017-06-01

    Different facets of biodiversity other than species numbers are increasingly appreciated as critical for maintaining the function of ecosystems and their services to humans. While new international policy and assessment processes such as the Intergovernmental Science-Policy Platform on Biodiversity and Ecosystem Services (IPBES) recognize the importance of an increasingly global, quantitative and comprehensive approach to biodiversity protection, most insights are still focused on a single facet of biodiversity—species. Here we broaden the focus and provide an evaluation of how much of the world’s species, functional and phylogenetic diversity of birds and mammals is currently protected and the scope for improvement. We show that the large existing gaps in the coverage for each facet of diversity could be remedied by a slight expansion of protected areas: an additional 5% of the land has the potential to more than triple the protected range of species or phylogenetic or functional units. Further, the same areas are often priorities for multiple diversity facets and for both taxa. However, we find that the choice of conservation strategy has a fundamental effect on outcomes. It is more difficult (that is, requires more land) to maximize basic representation of the global biodiversity pool than to maximize local diversity. Overall, species and phylogenetic priorities are more similar to each other than they are to functional priorities, and priorities for the different bird biodiversity facets are more similar than those of mammals. Our work shows that large gains in biodiversity protection are possible, while also highlighting the need to explicitly link desired conservation objectives and biodiversity metrics. We provide a framework and quantitative tools to advance these goals for multi-faceted biodiversity conservation.

  9. Noninflammatory Joint Contractures Arising from Immobility: Animal Models to Future Treatments

    PubMed Central

    Wong, Kayleigh; Trudel, Guy; Laneuville, Odette

    2015-01-01

    Joint contractures, defined as the limitation in the passive range of motion of a mobile joint, can be classified as noninflammatory diseases of the musculoskeletal system. The pathophysiology is not well understood; limited information is available on causal factors, progression, the pathophysiology involved, and prediction of response to treatment. The clinical heterogeneity of joint contractures combined with the heterogeneous contribution of joint connective tissues to joint mobility presents challenges to the study of joint contractures. Furthermore, contractures are often a symptom of a wide variety of heterogeneous disorders that are in many cases multifactorial. Extended immobility has been identified as a causal factor and evidence is provided from both experimental and epidemiology studies. Of interest is the involvement of the joint capsule in the pathophysiology of joint contractures and lack of response to remobilization. While molecular pathways involved in the development of joint contractures are being investigated, current treatments focus on physiotherapy, which is ineffective on irreversible contractures. Future treatments may include early diagnosis and prevention. PMID:26247029

  10. Subperiosteal Transmission Of Intra-Articular Pressure Between Articulated And Stationary Joints

    PubMed Central

    Pitkin, Mark; Muppavarapu, Raghuveer; Cassidy, Charles; Pitkin, Emil

    2015-01-01

    Hydrostatic pressures can be transmitted between synovial capsules. In each of ten rabbits, we simultaneously measured pressure in two joints, one of which was passively ranged, and the other of which was kept stationary. The intra-articular pressure inside the stationary joint changed every time its companion joint was ranged. But the pressure in the stationary joint did not change when the periosteum was transected above the ranged joint. This phenomenon was observed in all four animals that served as their own controls. The study suggests that the intra-articular pressure was transmitted through the space between the periosteum and the bone surface. Alternative explanations, like measurements of venous blood pressure, did not show correlation with hydrostatic pressure changes in the joints. The Floating Skeleton concept suggests a biomechanical rationale for this newly observed phenomenon: that there exists a subperiosteal hydrostatic connection of synovial joints, and that this “net” distributes excess pressures among joints through the periosteal sheath to sustain the integrity of the joint contacting surfaces over a lifetime. PMID:25632015

  11. Experimental measurement on movement of spiral-type capsule endoscope

    PubMed Central

    Yang, Wanan; Dai, Houde; He, Yong; Qin, Fengqing

    2016-01-01

    Wireless capsule endoscope achieved great success, however, the maneuvering of wireless capsule endoscope is challenging at present. A magnetic driving instrument, including two bar magnets, a stepper motor, a motor driver, a motor controller, and a power supplier, was developed to generate rotational magnetic fields. Permanent magnet ring, magnetized as S and N poles radially and mounted spiral structure on the surface, acted as a capsule. The maximum torque passing to the capsule, rotational synchronization of capsule and motor, and the translational speed of capsule, were measured in ex vivo porcine large intestine. The experimental results illustrate that the rotational movement of the spiral-type capsule in the intestine is feasible and the cost of the magnetic driving equipment is low. As a result, the solution is promising in the future controllability. PMID:26848279

  12. Experimental measurement on movement of spiral-type capsule endoscope.

    PubMed

    Yang, Wanan; Dai, Houde; He, Yong; Qin, Fengqing

    2016-01-01

    Wireless capsule endoscope achieved great success, however, the maneuvering of wireless capsule endoscope is challenging at present. A magnetic driving instrument, including two bar magnets, a stepper motor, a motor driver, a motor controller, and a power supplier, was developed to generate rotational magnetic fields. Permanent magnet ring, magnetized as S and N poles radially and mounted spiral structure on the surface, acted as a capsule. The maximum torque passing to the capsule, rotational synchronization of capsule and motor, and the translational speed of capsule, were measured in ex vivo porcine large intestine. The experimental results illustrate that the rotational movement of the spiral-type capsule in the intestine is feasible and the cost of the magnetic driving equipment is low. As a result, the solution is promising in the future controllability.

  13. Oxidation of CO by NO on planar and faceted Ir(210)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Wenhua; Bartynski, Robert A.; Kaghazchi, Payam

    2012-06-11

    Oxidation of CO by pre-adsorbed NO has been studied on planar Ir(210) and nanofaceted Ir(210) with average facet sizes of 5 nm and 14 nm by temperature programmed desorption (TPD). Both surfaces favor oxidation of CO to CO 2, which is accompanied by simultaneous reduction of NO with high selectivity to N 2. At low NO pre-coverage, the temperature (T i) for the onset of CO 2 desorption as well as CO 2 desorption peak temperature (T p) decreases with increasing CO exposure, and NO dissociation is affected by co-adsorbed CO. At high NO pre-coverage, T i and T pmore » are independent of CO exposure, and co-adsorbed CO has no influence on dissociation of NO. Moreover, at low NO pre-coverage, planar Ir(210) is more active than faceted Ir(210) for oxidation of CO to CO 2: T i and T p are much lower on planar Ir(210) than that on faceted Ir(210). In addition, faceted Ir(210) with an average facet size of 5 nm is more active for oxidation of CO to CO 2 than faceted Ir(210) with an average facet size of 14 nm, i.e., oxidation of CO by pre-adsorbed NO on faceted Ir(210) exhibits size effects on the nanometer scale. In comparison, at low O pre-coverage planar Ir(210) is more active than faceted Ir(210) for oxidation of CO to CO 2 but no evidence has been found for size effects in oxidation of CO by pre-adsorbed oxygen on faceted Ir(210) for average facet sizes of 5 nm and 14 nm. The TPD data indicate the same reaction pathway for CO 2 formation from CO + NO and CO + O reactions on planar Ir(210). Lastly, the adsorption sites of CO, NO, O, CO + O, and CO + NO on Ir are characterized by density functional theory.« less

  14. Simulation and optimization of faceted structure for illumination

    NASA Astrophysics Data System (ADS)

    Liu, Lihong; Engel, Thierry; Flury, Manuel

    2016-04-01

    The re-direction of incoherent light using a surface containing only facets with specific angular values is proposed. A new photometric approach is adopted since the size of each facet is large in comparison with the wavelength. A reflective configuration is employed to avoid the dispersion problems of materials. The irradiance distribution of the reflected beam is determined by the angular position of each facet. In order to obtain the specific irradiance distribution, the angular position of each facet is optimized using Zemax OpticStudio 15 software. A detector is placed in the direction which is perpendicular to the reflected beam. According to the incoherent irradiance distribution on the detector, a merit function needs to be defined to pilot the optimization process. The two dimensional angular position of each facet is defined as a variable which is optimized within a specified varying range. Because the merit function needs to be updated, a macro program is carried out to update this function within Zemax. In order to reduce the complexity of the manual operation, an automatic optimization approach is established. Zemax is in charge of performing the optimization task and sending back the irradiance data to Matlab for further analysis. Several simulation results are given for the verification of the optimization method. The simulation results are compared to those obtained with the LightTools software in order to verify our optimization method.

  15. Fabrication of capsule assemblies, phase 3

    NASA Technical Reports Server (NTRS)

    Keeton, A. R.; Stemann, L. G.

    1973-01-01

    Thirteen capsule assemblies were fabricated for evaluation of fuel pin design concepts for a fast spectrum lithium cooled compact space power reactor. These instrumented assemblies were designed for real time test of prototype fuel pins. Uranium mononitride fuel pins were encased in AISI 304L stainless steel capsules. Fabrication procedures were fully qualified by process development and assembly qualification tests. Instrumentation reliability was achieved utilizing specially processed and closely controlled thermocouple hot zone fabrication and by thermal screening tests. Overall capsule reliability was achieved with an all electron beam welded assembly.

  16. Stopping mechanism for capsule endoscope using electrical stimulus.

    PubMed

    Woo, Sang Hyo; Kim, Tae Wan; Cho, Jin Ho

    2010-01-01

    An ingestible capsule, which has the ability to stop at certain locations in the small intestine, was designed and implemented to monitor intestinal diseases. The proposed capsule can contract the small intestine by using electrical stimuli; this contraction causes the capsule to stop when the maximum static frictional force (MSFF) is larger than the force of natural peristalsis. In vitro experiments were carried out to verify the feasibility of the capsule, and the results showed that the capsule was successfully stopped in the small intestine. Various electrodes and electrical stimulus parameters were determined on the basis of the MSFF. A moderate increment of the MSFF (12.7 +/- 4.6 gf at 5 V, 10 Hz, and 5 ms) and the maximum increment of the MSFF (56.5 +/- 9.77 gf at 20 V, 10 Hz, and 5 ms) were obtained, and it is sufficient force to stop the capsule.

  17. Identification of a functional capsule locus in Streptococcus mitis.

    PubMed

    Rukke, H V; Hegna, I K; Petersen, F C

    2012-04-01

    The polysaccharide capsule of Streptococcus pneumoniae is a hallmark for virulence in humans. In its close relative Streptococcus mitis, a common human commensal, analysis of the sequenced genomes of six strains revealed the presence of a putative capsule locus in four of them. We constructed an isogenic S. mitis mutant from the type strain that lacked the 19 open reading frames in the capsule locus (Δcps mutant), using a deletion strategy similar to previous capsule functional studies in S. pneumoniae. Transmission electron microscopy and atomic force microscopy revealed a capsule-like structure in the S. mitis type strain that was absent or reduced in the Δcps mutant. Since S. mitis are predominant oral colonizers of tooth surfaces, we addressed the relevance of the capsule locus for the S. mitis overall surface properties, autoaggregation and biofilm formation. The capsule deletion resulted in a mutant with approximately two-fold increase in hydrophobicity. Binding to the Stains-all cationic dye was reduced by 40%, suggesting a reduction in the overall negative surface charge of the mutant. The mutant exhibited also increased autoaggregation in coaggregation buffer, and up to six-fold increase in biofilm levels. The results suggested that the capsule locus is associated with production of a capsule-like structure in S. mitis and indicated that the S. mitis capsule-like structure may confer surface attributes similar to those associated with the capsule in S. pneumoniae. © 2011 John Wiley & Sons A/S.

  18. 21 CFR 520.608 - Dicloxacillin sodium monohydrate capsules.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Dicloxacillin sodium monohydrate capsules. 520.608 Section 520.608 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Dicloxacillin sodium monohydrate capsules. (a) Specifications. Each capsule contains dicloxacillin sodium...

  19. 21 CFR 520.608 - Dicloxacillin sodium monohydrate capsules.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 6 2012-04-01 2012-04-01 false Dicloxacillin sodium monohydrate capsules. 520.608 Section 520.608 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Dicloxacillin sodium monohydrate capsules. (a) Specifications. Each capsule contains dicloxacillin sodium...

  20. 21 CFR 520.608 - Dicloxacillin sodium monohydrate capsules.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 6 2011-04-01 2011-04-01 false Dicloxacillin sodium monohydrate capsules. 520.608 Section 520.608 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Dicloxacillin sodium monohydrate capsules. (a) Specifications. Each capsule contains dicloxacillin sodium...

  1. Faceted ceramic fibers, tapes or ribbons and epitaxial devices therefrom

    DOEpatents

    Goyal, Amit

    2013-07-09

    A crystalline article includes a single-crystal ceramic fiber, tape or ribbon. The fiber, tape or ribbon has at least one crystallographic facet along its length, which is generally at least one meter long. In the case of sapphire, the facets are R-plane, M-plane, C-plane or A-plane facets. Epitaxial articles, including superconducting articles, can be formed on the fiber, tape or ribbon.

  2. Faceted ceramic fibers, tapes or ribbons and epitaxial devices therefrom

    DOEpatents

    Goyal, Amit [Knoxville, TN

    2012-07-24

    A crystalline article includes a single-crystal ceramic fiber, tape or ribbon. The fiber, tape or ribbon has at least one crystallographic facet along its length, which is generally at least one meter long. In the case of sapphire, the facets are R-plane, M-plane, C-plane or A-plane facets. Epitaxial articles, including superconducting articles, can be formed on the fiber, tape or ribbon.

  3. Production, deformation and mechanical investigation of magnetic alginate capsules

    NASA Astrophysics Data System (ADS)

    Zwar, Elena; Kemna, Andre; Richter, Lena; Degen, Patrick; Rehage, Heinz

    2018-02-01

    In this article we investigated the deformation of alginate capsules in magnetic fields. The sensitivity to magnetic forces was realised by encapsulating an oil in water emulsion, where the oil droplets contained dispersed magnetic nanoparticles. We solved calcium ions in the aqueous emulsion phase, which act as crosslinking compounds for forming thin layers of alginate membranes. This encapsulating technique allows the production of flexible capsules with an emulsion as the capsule core. It is important to mention that the magnetic nanoparticles were stable and dispersed throughout the complete process, which is an important difference to most magnetic alginate-based materials. In a series of experiments, we used spinning drop techniques, capsule squeezing experiments and interfacial shear rheology in order to determine the surface Young moduli, the surface Poisson ratios and the surface shear moduli of the magnetically sensitive alginate capsules. In additional experiments, we analysed the capsule deformation in magnetic fields. In spinning drop and capsule squeezing experiments, water droplets were pressed out of the capsules at elevated values of the mechanical load. This phenomenon might be used for the mechanically triggered release of water-soluble ingredients. After drying the emulsion-filled capsules, we produced capsules, which only contained a homogeneous oil phase with stable suspended magnetic nanoparticles (organic ferrofluid). In the dried state, the thin alginate membranes of these particles were rather rigid. These dehydrated capsules could be stored at ambient conditions for several months without changing their properties. After exposure to water, the alginate membranes rehydrated and became flexible and deformable again. During this swelling process, water diffused back in the capsule. This long-term stability and rehydration offers a great spectrum of different applications as sensors, soft actuators, artificial muscles or drug delivery systems.

  4. Design and synthesis of organic-inorganic hybrid capsules for biotechnological applications.

    PubMed

    Shi, Jiafu; Jiang, Yanjun; Wang, Xiaoli; Wu, Hong; Yang, Dong; Pan, Fusheng; Su, Yanlei; Jiang, Zhongyi

    2014-08-07

    Organic-inorganic hybrid capsules, which typically possess a hollow lumen and a hybrid wall, have emerged as a novel and promising class of hybrid materials and have attracted enormous attention. In comparison to polymeric capsules or inorganic capsules, the hybrid capsules combine the intrinsic physical/chemical properties of the organic and inorganic moieties, acquire more degrees of freedom to manipulate multiple interactions, create hierarchical structures and integrate multiple functionalities. Thus, the hybrid capsules exhibit superior mechanical strength (vs. polymeric capsules) and diverse functionalities (vs. inorganic capsules), which may give new opportunities to produce high-performance materials. Much effort has been devoted to exploring innovative and effective methods for the synthesis of hybrid capsules that exhibit desirable performance in target applications. This tutorial review firstly presents a brief description of the capsular structure and hybrid materials in nature, then classifies the hybrid capsules into molecule-hybrid capsules and nano-hybrid capsules based upon the size of the organic and inorganic moieties in the capsule wall, followed by a detailed discussion of the design and synthesis of the hybrid capsules. For each kind of hybrid capsule, the state-of-the-art synthesis methods are described in detail and a critical comment is embedded. The applications of these hybrid capsules in biotechnological areas (biocatalysis, drug delivery, etc.) have also been summarized. Hopefully, this review will offer a perspective and guidelines for the future research and development of hybrid capsules.

  5. Gettering capsule for removing oxygen from liquid lithium systems

    NASA Technical Reports Server (NTRS)

    Tower, L. K.; Breitwieser, R.

    1973-01-01

    Capsule consisting of tantalum shell lined with tantalum screen and partially filled with lithium and pieces of yttrium is immersed in hot lithium stream. Oxygen is removed from stream by being absorbed by gettering capsule. Oxygen passes through capsule wall and into lithium inside capsule where it reacts with yttrium to form Y2O3.

  6. Electrostatics-driven assembly of uni-lamellar catanionic facetted vesicles

    NASA Astrophysics Data System (ADS)

    Leung, Cheuk-Yui; Palmer, Liam; Kewalramani, Sumit; Sknepnek, Rastko; Vernizzi, Graziano; Greenfield, Megan; Stupp, Samuel; Bedzyk, Michael; Olvera de La Cruz, Monica

    2012-02-01

    Nature utilizes shape to generate function. Organelle and halophilic bacteria wall envelopes, for example, adopt various polyhedral shapes to compartmentalize matter. The origin of these shapes is unknown. A large variety of shell geometries, either fully faceted polyhedra or mixed Janus-like vesicles with faceted and curved domains that resemble cellular shells can be generated by coassembling water-insoluble anionic (--1) amphiphiles with high valence cationic (+2 and +3) amphiphiles. Electron microscopy, X-ray scattering, theory and simulations demonstrate that the resulting faceted ionic shells are crystalline, and stable at high salt concentrations. The crystallization of the co-assembled single tail amphiphiles is induced by ionic correlations, and modified by the solution pH. This work promotes the design of faceted shapes for various applications and improves our understanding of the origin of polyhedral shells in nature.

  7. [Dorsal capsular imbrication for dorsal instability of the distal radioulnar joint].

    PubMed

    Unglaub, F; Manz, S; Bruckner, T; Leclère, F M; Hahn, P; Wolf, M B

    2013-12-01

    To stabilize the distal radioulnar joint (DRUJ) by performing dorsal capsular imbrication in patients presenting with dorsal instability. The goal was to reduce pain and prevent the occurrence of posttraumatic arthrosis. Posttraumatic dorsal instability of the DRUJ with missing block while performing translational activities in the DRUJ or subluxation while actively rotating the forearm. Cases, in which other stabilizing techniques, such as, sutures of the triangular fibrocartilage complex failed. DRUJ arthrosis, previous surgical interventions to the capsule area of the DRUJ, instabilities due to osseous reasons (malposition or pseudarthrosis) should already have been treated. Dorsal approach and opening of the 5th extensor compartment to expose the dorsal joint capsule. A longitudinal division of the capsule was performed and sufficient tissue on the radial and ulnar border was retained to ensure a solid suture technique. Then 2 U-shaped sutures using FiberWire suture material were made. Correction of the malposition and repositioning the forearm into supination. Tightening of the prepared capsule sutures and closing of the retinaculum with a resorbable suture. Patients wore a long-arm cast with the forearm being in supination for a period of 4 weeks. Following cast removal, patients wore a forearm splint for a period of 4 weeks to limit forearm pronation/supination at 45°. Full load on the wrist was allowed after 12 weeks. The subjective and functional outcomes of 20 patients having received capsular imbrication using this technique were good and entailed no significant complications. The postoperative DASH was 15.8 points. Of the 20 patients, 17 patients (85%) had a reduction of pain. Symptoms of DRUJ instability could be reduced in 18 patients (90%). Pronation/supination of the wrist was not restricted postoperatively.

  8. Relative ratios of collagen composition of periarticular tissue of joints of the upper limb.

    PubMed

    Cheah, A; Harris, A; Le, W; Huang, Y; Yao, J

    2017-07-01

    We investigated the relative ratios of collagen composition of periarticular tissue of the elbow, wrist, metacarpophalangeal, proximal and distal interphalangeal joints. Periarticulat tissue, which we defined as the ligaments, palmar plate and capsule, was harvested from ten fresh-frozen cadaveric upper limbs, yielding 50 samples. The mean paired differences (95% confidence interval) of the relative ratios of collagen between the five different joints were estimated using mRNA expression of collagen in the periarticular tissue. We found that the relative collagen composition of the elbow was not significantly different to that of the proximal interphalangeal joint, nor between the proximal interphalangeal joint and distal interphalangeal joint, whereas the differences in collagen composition between all the other paired comparisons of the joints had confidence intervals that did not include zero.

  9. Motion of an elastic capsule in a square microfluidic channel.

    PubMed

    Kuriakose, S; Dimitrakopoulos, P

    2011-07-01

    In the present study we investigate computationally the steady-state motion of an elastic capsule along the centerline of a square microfluidic channel and compare it with that in a cylindrical tube. In particular, we consider a slightly over-inflated elastic capsule made of a strain-hardening membrane with comparable shearing and area-dilatation resistance. Under the conditions studied in this paper (i.e., small, moderate, and large capsules at low and moderate flow rates), the capsule motion in a square channel is similar to and thus governed by the same scaling laws with the capsule motion in a cylindrical tube, even though in the channel the cross section in the upstream portion of large capsules is nonaxisymmetric (i.e., square-like with rounded corners). When the hydrodynamic forces on the membrane increase, the capsule develops a pointed downstream edge and a flattened rear (possibly with a negative curvature) so that the restoring tension forces are increased as also happens with droplets. Membrane tensions increase significantly with the capsule size while the area near the downstream tip is the most probable to rupture when a capsule flows in a microchannel. Because the membrane tensions increase with the interfacial deformation, a suitable Landau-Levich-Derjaguin-Bretherton analysis reveals that the lubrication film thickness h for large capsules depends on both the capillary number Ca and the capsule size a; our computations determine the latter dependence to be (in dimensionless form) h ~ a(-2) for the large capsules studied in this work. For small and moderate capsule sizes a, the capsule velocity Ux and additional pressure drop ΔP+ are governed by the same scaling laws as for high-viscosity droplets. The velocity and additional pressure drop of large thick capsules also follow the dynamics of high-viscosity droplets, and are affected by the lubrication film thickness. The motion of our large thick capsules is characterized by a Ux-U ~ h ~ a(-2

  10. Motion of an elastic capsule in a square microfluidic channel

    PubMed Central

    Kuriakose, S.; Dimitrakopoulos, P.

    2013-01-01

    In the present study we investigate computationally the steady-state motion of an elastic capsule along the centerline of a square microfluidic channel and compare it with that in a cylindrical tube. In particular, we consider a slightly over-inflated elastic capsule made of a strain-hardening membrane with comparable shearing and area-dilatation resistance. Under the conditions studied in this paper (i.e. small, moderate and large capsules at low and moderate flow rates), the capsule motion in a square channel is similar to, and thus governed by the same scaling laws with the capsule motion in a cylindrical tube, even though in the channel the cross-section in the upstream portion of large capsules is non-axisymmetric (i.e. square-like with rounded corners). When the hydrodynamic forces on the membrane increase, the capsule develops a pointed downstream edge and a flattened rear (possibly with a negative curvature) so that the restoring tension forces are increased as also happens with droplets. Membrane tensions increase significantly with the capsule size while the area near the downstream tip is the most probable to rupture when a capsule flows in a microchannel. Because the membrane tensions increase with the interfacial deformation, a suitable Landau-Levich-Derjaguin-Bretherton analysis reveals that the lubrication film thickness h for large capsules depends on both the capillary number Ca and the capsule size a; our computations determine the latter dependence to be (in dimensionless form) h ~ a−2 for the large capsules studied in this work. For small and moderate capsule sizes a, the capsule velocity Ux and additional pressure drop ΔP+ are governed by the same scaling laws as for high-viscosity droplets. The velocity and additional pressure drop of large thick capsules also follow the dynamics of high-viscosity droplets, and are affected by the lubrication film thickness. The motion of our large thick capsules is characterized by a Ux−u~h~a−2

  11. Axial traction magnetic resonance imaging (MRI) of the glenohumeral joint in healthy volunteers: initial experience.

    PubMed

    Garwood, Elisabeth R; Souza, Richard B; Zhang, Amy; Zhang, Alan L; Ma, C Benjamin; Link, Thomas M; Motamedi, Daria

    Evaluate technical feasibility and potential applications of glenohumeral (GH) joint axial traction magnetic resonance imaging (MRI) in healthy volunteers. Eleven shoulders were imaged in neutral and with 4kg axial traction at 3T. Quantitative measurements were assessed. Axial traction was well tolerated. There was statistically significant widening of the superior GH joint space (p=0.002) and acromial angle (p=0.017) with traction. Inter-rater agreement was high. GH joint axial traction MRI is technically feasible and well tolerated in volunteers. Traction of the capsule, widening of the superior GH joint space and acromial angle were observed. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Facet-controlled facilitation of PbS nanoarchitectures by understanding nanocrystal growth

    NASA Astrophysics Data System (ADS)

    Loc, Welley Siu; Quan, Zewei; Lin, Cuikun; Pan, Jinfong; Wang, Yuxuan; Yang, Kaikun; Jian, Wen-Bin; Zhao, Bo; Wang, Howard; Fang, Jiye

    2015-11-01

    Nanostructured lead sulphide is a significant component in a number of energy-related sustainable applications such as photovoltaic cells and thermoelectric components. In many micro-packaging processes, dimensionality-controlled nano-architectures as building blocks with unique properties are required. This study investigates different facet-merging growth behaviors through a wet-chemical synthetic strategy to produce high-quality controlled nanostructures of lead sulphide in various dimensionalities. It was found that 1D nanowires or 2D nanosheets can be obtained by the merging of reactive {111}- or {110}-facets, respectively, while promoting {100} facets in the early stages after nucleation leads to the growth of 0D nanocubes. The influence of temperature, capping ligands and co-solvent in facilitating the crystal facet growth of each intermediate seed is also demonstrated. The novelty of this work is characterized by the delicate manipulation of various PbS nanoarchitectures based on the comprehension of the facet-merging evolution. The synthesis of facet-controlled PbS nanostructures could provide novel building blocks with desired properties for use in many applications.Nanostructured lead sulphide is a significant component in a number of energy-related sustainable applications such as photovoltaic cells and thermoelectric components. In many micro-packaging processes, dimensionality-controlled nano-architectures as building blocks with unique properties are required. This study investigates different facet-merging growth behaviors through a wet-chemical synthetic strategy to produce high-quality controlled nanostructures of lead sulphide in various dimensionalities. It was found that 1D nanowires or 2D nanosheets can be obtained by the merging of reactive {111}- or {110}-facets, respectively, while promoting {100} facets in the early stages after nucleation leads to the growth of 0D nanocubes. The influence of temperature, capping ligands and co-solvent in

  13. Light weight escape capsule for fighter aircraft

    NASA Technical Reports Server (NTRS)

    Robert, James A.

    1988-01-01

    Emergency crew escape capabilities have been less than adequate for fighter aircraft since before WW II. From the over-the-side bailout of those days through the current ejection seat with a rocket catapult, escaping from a disabled aircraft has been risky at best. Current efforts are underway toward developing a high-tech, smart ejection seat that will give fighter pilots more room to live in the sky, but an escape capsule is needed to meet current and future fighter envelopes. Escape capsules have a bad reputation due to past examples of high weight, poor performance and great complexity. However, the advantages available demand that a capsule be developed. This capsule concept will minimize the inherent disavantages and incorporate the benefits while integrating all aspects of crew station design. The resulting design is appropriate for a crew station of the year 2010 and includes improved combat acceleration protection, chemical or biological combat capability, improved aircraft to escape system interaction, and the highest level of escape performance achievable. The capsule is compact, which can allow a reduced aircraft size and weighs only 1200 lb. The escape system weight penalty is only 120 lb higher than that for the next ejection seat and the capsule has a corresponding increase in performance.

  14. Development of remote welding techniques for in-pile IASCC capsules and evaluation of material integrity on capsules for long irradiation period

    NASA Astrophysics Data System (ADS)

    Shibata, A.; Nakano, J.; Ohmi, M.; Kawamata, K.; Nakagawa, T.; Tsukada, T.

    2012-03-01

    To simulate irradiation assisted stress corrosion cracking (IASCC) behavior by in-pile experiments, it is necessary to irradiate specimens up to a neutron fluence that is higher than the IASCC threshold fluence. Pre-irradiated specimens must be relocated from pre-irradiation capsules to in-pile capsules. Hence, a remote welding machine has been developed. And the integrity of capsule housing for a long term irradiation was evaluated by tensile tests in air and slow strain rate tests in water. Two type specimens were prepared. Specimens were obtained from the outer tubes of capsule irradiated to 1.0-3.9 × 1026 n/m2 (E > 1 MeV). And specimens were irradiated in a leaky capsule to 0.03-1.0 × 1026 n/m2. Elongation more than 15% in tensile test at 423 K was confirmed and no IGSCC fraction was shown in SSRT at 423 K which was estimated as temperature at the outer tubes of the capsule under irradiation.

  15. Crack Front Segmentation and Facet Coarsening in Mixed-Mode Fracture

    NASA Astrophysics Data System (ADS)

    Chen, Chih-Hung; Cambonie, Tristan; Lazarus, Veronique; Nicoli, Matteo; Pons, Antonio J.; Karma, Alain

    2015-12-01

    A planar crack generically segments into an array of "daughter cracks" shaped as tilted facets when loaded with both a tensile stress normal to the crack plane (mode I) and a shear stress parallel to the crack front (mode III). We investigate facet propagation and coarsening using in situ microscopy observations of fracture surfaces at different stages of quasistatic mixed-mode crack propagation and phase-field simulations. The results demonstrate that the bifurcation from propagating a planar to segmented crack front is strongly subcritical, reconciling previous theoretical predictions of linear stability analysis with experimental observations. They further show that facet coarsening is a self-similar process driven by a spatial period-doubling instability of facet arrays.

  16. Polar tent for reduced perturbation of NIF ignition capsules

    NASA Astrophysics Data System (ADS)

    Hammel, B. A.; Pickworth, L.; Stadermann, M.; Field, J.; Robey, H.; Scott, H. A.; Smalyuk, V.

    2016-10-01

    In simulations, a tent that contacts the capsule near the poles and departs tangential to the capsule surface greatly reduces the capsule perturbation, and the resulting mass injected into the hot-spot, compared to current capsule support methods. Target fabrication appears feasible with a layered tent (43-nm polyimide + 8-nm C) for increased stiffness. We are planning quantitative measurements of the resulting shell- ρR perturbation near peak implosion velocity (PV) using enhanced self-emission backlighting, achieved by adding 1% Ar to the capsule fill in Symcaps (4He + H). Layered DT implosions are also planned for an integrated test of capsule performance. We will describe the design and simulation predictions. Prepared by LLNL under Contract DE-AC52-07NA27344.

  17. Selectivity of Glycine for Facets on Gold Nanoparticles.

    PubMed

    Shao, Qing; Hall, Carol K

    2018-04-05

    The performance of nanoparticles in medical applications depends on their interactions with various molecules. Despite extensive research on this subject, it remains unclear where on an inhomogeneous nanoparticle molecules prefer to adsorb. Here we investigate the selectivity of glycine molecules for facets on five bare gold nanoparticles with diameters from 1.0 to 5.0 nm. Well-tempered metadynamics simulations are conducted to calculate the adsorption free-energy landscapes of a glycine molecule on various locations for the five gold nanoparticles in explicit water. We also calculate the glycine molecule's adsorption free energies on the five gold nanoparticles in vacuum and on three flat gold surfaces as a reference. The simulation results show that glycine molecules prefer to adsorb on the (110) facet for the 1.0 and 2.0 nm nanoparticles, the edges for the 3.0 nm nanoparticle, and the (111) facet for the 4.0 and 5.0 nm nanoparticles in water. The effect of water solvent on the selectivity is investigated through comparing the adsorption free-energy landscapes for glycine molecules on the nanoparticles in water and in vacuum. The area of the facet plays a key role in determining the selectivity of glycine molecules for the different facets, especially the shift of the selectivity as the nanoparticle diameter changes. Our simulations suggest that nanoparticle size and shape can be engineered to control the preferred adsorption location of molecules.

  18. Domains and facets: hierarchical personality assessment using the revised NEO personality inventory.

    PubMed

    Costa, P T; McCrae, R R

    1995-02-01

    Personality traits are organized hierarchically, with narrow, specific traits combining to define broad, global factors. The Revised NEO Personality Inventory (NEO-PI-R; Costa & McCrae, 1992c) assesses personality at both levels, with six specific facet scales in each of five broad domains. This article describes conceptual issues in specifying facets of a domain and reports evidence on the validity of NEO-PI-R facet scales. Facet analysis-the interpretation of a scale in terms of the specific facets with which it correlates-is illustrated using alternative measures of the five-factor model and occupational scales. Finally, the hierarchical interpretation of personality profiles is discussed. Interpretation on the domain level yields a rapid understanding of the individual interpretation of specific facet scales gives a more detailed assessment.

  19. General route for the assembly of functional inorganic capsules.

    PubMed

    Akartuna, Ilke; Tervoort, Elena; Studart, André R; Gauckler, Ludwig J

    2009-11-03

    Semipermeable, hollow capsules are attractive materials for the encapsulation and delivery of active agents in food processing, pharmaceutical and agricultural industries, and biomedicine. These capsules can be produced by forming a solid shell of close packed colloidal particles, typically polymeric particles, at the surface of emulsion droplets. However, current methods to prepare such capsules may involve multistep chemical procedures to tailor the surface chemistry of particles or are limited to particles that exhibit inherently the right hydrophobic-hydrophilic balance to adsorb around emulsion droplets. In this work, we describe a general and simple method to fabricate semipermeable, inorganic capsules from emulsion droplets stabilized by a wide variety of colloidal metal oxide particles. The assembly of particles at the oil-water interface is induced by the in situ hydrophobization of the particle surface through the adsorption of short amphiphilic molecules. The adsorption of particles at the interface leads to stable capsules comprising a single layer of particles in the outer shell. Such capsules can be used in the wet state or can be further processed into dry capsules. The permeability of the capsules can be modified by filling the interstices between the shell particles with polymeric or inorganic species. Functional capsules with biocompatible, bioresorbable, heat-resistant, chemical-resistant, and magnetic properties were prepared using alumina, silica, iron oxide, or tricalcium phosphate as particles in the shell.

  20. 21 CFR 520.260 - n-Butyl chloride capsules.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false n-Butyl chloride capsules. 520.260 Section 520.260... DRUGS, FEEDS, AND RELATED PRODUCTS ORAL DOSAGE FORM NEW ANIMAL DRUGS § 520.260 n-Butyl chloride capsules. (a)(1) Specifications. n-Butyl chloride capsules, veterinary contain 272 milligrams or 816 milligrams...

  1. IRRADIATION-CAPSULE STUDY OF URANIUM MONOCARBIDE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Price, R.B.; Stahl, D.; Stang, J.H.

    1960-03-01

    Small cylindrical specimens of enriched UC were irradiated to evaluate usefulness as a high-temperature fuel for stationary power reactors. Detailed thermal and nuclear analyses were made to arrive at an appropriate capsule design on the basis of target specimen center-line temperature ( approximately 1500 deg F), specimen surface temperature (1100 deg F), specimen composition (U--5 wt.% C), and acapsule o.d. of 1.125 in. Temperature data from thermocouples inside the capsule indicated that five of the six capsules irradiated operated at close to the design conditions. Irradiation periods for individual capsules were varied to give burnups ranging from 1,000 to 20,000more » Mwd/t of U. Preliminary evidence indicates that this range of burnups was achieved. By using temperature and heat-flux data from the actual irradiations to estimate effective in-pile specimen thermal conductivities, it was found that the conductivity did not appear to vary during the exposures. (auth)« less

  2. Problem of time: facets and Machian strategy.

    PubMed

    Anderson, Edward

    2014-10-01

    The problem of time is that "time" in each of ordinary quantum theory and general relativity are mutually incompatible notions. This causes difficulties in trying to put these two theories together to form a theory of quantum gravity. The problem of time has eight facets in canonical approaches. I clarify that all but one of these facets already occur at the classical level, and reconceptualize and re-name some of these facets as follows. The frozen formalism problem becomes temporal relationalism, the thin sandwich problem becomes configurational relationalism, via the notion of best matching. The problem of observables becomes the problem of beables, and the functional evolution problem becomes the constraint closure problem. I also outline how each of the global and multiple-choice problems of time have their own plurality of facets. This article additionally contains a local resolution to the problem of time at the conceptual level and which is actually realizable for the relational triangle and minisuperspace models. This resolution is, moreover, Machian, and has three levels: classical, semiclassical, and a combined semiclassical-histories-timeless records scheme. I end by delineating the current frontiers of this program toward resolution of the problem of time in the cases of full general relativity and of slightly inhomogeneous cosmology. © 2014 New York Academy of Sciences.

  3. [Improvement of Digital Capsule Endoscopy System and Image Interpolation].

    PubMed

    Zhao, Shaopeng; Yan, Guozheng; Liu, Gang; Kuang, Shuai

    2016-01-01

    Traditional capsule image collects and transmits analog image, with weak anti-interference ability, low frame rate, low resolution. This paper presents a new digital image capsule, which collects and transmits digital image, with frame rate up to 30 frames/sec and pixels resolution of 400 x 400. The image is compressed in the capsule, and is transmitted to the outside of the capsule for decompression and interpolation. A new type of interpolation algorithm is proposed, which is based on the relationship between the image planes, to obtain higher quality colour images. capsule endoscopy, digital image, SCCB protocol, image interpolation

  4. Facet-controlled facilitation of PbS nanoarchitectures by understanding nanocrystal growth.

    PubMed

    Loc, Welley Siu; Quan, Zewei; Lin, Cuikun; Pan, Jinfong; Wang, Yuxuan; Yang, Kaikun; Jian, Wen-Bin; Zhao, Bo; Wang, Howard; Fang, Jiye

    2015-12-07

    Nanostructured lead sulphide is a significant component in a number of energy-related sustainable applications such as photovoltaic cells and thermoelectric components. In many micro-packaging processes, dimensionality-controlled nano-architectures as building blocks with unique properties are required. This study investigates different facet-merging growth behaviors through a wet-chemical synthetic strategy to produce high-quality controlled nanostructures of lead sulphide in various dimensionalities. It was found that 1D nanowires or 2D nanosheets can be obtained by the merging of reactive {111}- or {110}-facets, respectively, while promoting {100} facets in the early stages after nucleation leads to the growth of 0D nanocubes. The influence of temperature, capping ligands and co-solvent in facilitating the crystal facet growth of each intermediate seed is also demonstrated. The novelty of this work is characterized by the delicate manipulation of various PbS nanoarchitectures based on the comprehension of the facet-merging evolution. The synthesis of facet-controlled PbS nanostructures could provide novel building blocks with desired properties for use in many applications.

  5. Video capsule endoscopy: Perspectives of a revolutionary technique

    PubMed Central

    Bouchard, Simon; Ibrahim, Mostafa; Van Gossum, Andre

    2014-01-01

    Video capsule endoscopy (VCE) was launched in 2000 and has revolutionized direct endoscopic imaging of the gut. VCE is now a first-line procedure for exploring the small bowel in cases of obscure digestive bleeding and is also indicated in some patients with Crohn’s disease, celiac disease, and polyposis syndrome. A video capsule has also been designed for visualizing the esophagus in order to detect Barrett’s esophagus or esophageal varices. Different capsules are now available and differ with regard to dimensions, image acquisition rate, battery life, field of view, and possible optical enhancements. More recently, the use of VCE has been extended to exploring the colon. Within the last 5 years, tremendous developments have been made toward increasing the capabilities of the colon capsule. Although colon capsule cannot be proposed as a first-line colorectal cancer screening procedure, colon capsule may be used in patients with incomplete colonoscopy or in patients who are unwilling to undergo colonoscopy. In the near future, new technological developments will improve the diagnostic yield of VCE and broaden its therapeutic capabilities. PMID:25516644

  6. A multicenter, prospective, randomized comparison of a novel signal transmission capsule endoscope to an existing capsule endoscope.

    PubMed

    Choi, Eric H; Mergener, Klaus; Semrad, Carol; Fisher, Laurel; Cave, David R; Dodig, Milan; Burke, Carol; Leighton, Jonathan A; Kastenberg, David; Simpson, Peter; Sul, James; Bhattacharya, Kanishka; Charles, Roger; Gerson, Lauren; Weber, Luke; Eisen, Glenn; Reidel, Warren; Vargo, John J; Wakim-Fleming, Jamile; Lo, Simon K

    2013-08-01

    MiroCam, a capsule endoscope, uses a novel transmission technology, electric-field propagation, which uses the human body as a conduction medium for data transmission. To compare the ability of the MiroCam (MC) and PillCam (PC) to identify sources of obscure GI bleeding (OGIB). Prospective, multicenter, comparative study. Six academic hospitals. A total of 105 patients with OGIB. Patients ingested both the MC and PC capsules sequentially in a randomized fashion. Concordance of rates in identifying a source of OGIB, operational times, and rates of complete small-bowel examination. Data analysis resulted in 43 (48%) "abnormal" cases identifying a source of OGIB by either capsule. Twenty-four cases (55.8%) were positive by both capsules. There was negative agreement in 46 of 58 cases (79.3%). The κ index was 0.547 (χ(2) = 1.32; P = .36). In 12 cases, MC positively identified a source that was not seen on PC, whereas in 7 cases, PC positively identified a source that was not seen on MC. MC had a 5.6% higher rate of detecting small-bowel lesions (P = .54). MC captured images at 3 frames per second for 11.1 hours, and PC captured images at 2 frames per second for 7.8 hours (P < .0001). Complete small-bowel examination was achieved in 93.3% for MC and 84.3% for PC (P = .10). Readers were not blinded to the particular capsule they were reading. A positive diagnostic finding for OGIB was identified by either capsule in 48% of cases. The concordance rate between the 2 capsules was comparable to that of prior studies in identifying sources of small-bowel bleeding. The longer operational time of the MC may result in higher rates of complete small-bowel examination, which may, in turn, translate into a higher rate of detecting small-bowel lesions. ( NCT00878982.). Copyright © 2013 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  7. Effects of whole-body cryotherapy in the management of adhesive capsulitis of the shoulder.

    PubMed

    Ma, Sang-Yeol; Je, Hyun Dong; Jeong, Ji Hoon; Kim, Hae-Young; Kim, Hyeong-Dong

    2013-01-01

    To compare 2 different treatment approaches, physical therapy modalities, and joint mobilization versus whole-body cryotherapy (WBC) combined with physical therapy modalities and joint mobilization, for symptoms of adhesive capsulitis (AC) of the shoulder. A randomized trial. Hospital. Patients with AC of the shoulder (N=30). Patients were randomly assigned to 2 groups. The WBC group received physical therapy modalities, passive joint mobilization of the shoulder, and WBC, whereas the non-WBC group received only physical therapy modalities and passive joint mobilization of the shoulder. Visual analog scale (VAS), active range of motion (ROM) of flexion, abduction, internal and external rotation of the shoulder, and the American Shoulder and Elbow Surgeons Standardized Shoulder Assessment Form (ASES) were measured before and after the intervention. A statistically significant difference between groups was found for the VAS, active ROM of flexion, abduction, internal rotation, and external rotation, and the ASES with greater improvements in the WBC group (Ps<.01). Overall, both groups showed a significant improvement in all outcome measures and ROM measures from pre to post at a level of P<.01. There is significant improvement with the addition of WBC to treatment interventions in this sample of patients. Copyright © 2013 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  8. Analysis of Fission Products on the AGR-1 Capsule Components

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Paul A. Demkowicz; Jason M. Harp; Philip L. Winston

    2013-03-01

    The components of the AGR-1 irradiation capsules were analyzed to determine the retained inventory of fission products in order to determine the extent of in-pile fission product release from the fuel compacts. This includes analysis of (i) the metal capsule components, (ii) the graphite fuel holders, (iii) the graphite spacers, and (iv) the gas exit lines. The fission products most prevalent in the components were Ag-110m, Cs 134, Cs 137, Eu-154, and Sr 90, and the most common location was the metal capsule components and the graphite fuel holders. Gamma scanning of the graphite fuel holders was also performed tomore » determine spatial distribution of Ag-110m and radiocesium. Silver was released from the fuel components in significant fractions. The total Ag-110m inventory found in the capsules ranged from 1.2×10 2 (Capsule 3) to 3.8×10 1 (Capsule 6). Ag-110m was not distributed evenly in the graphite fuel holders, but tended to concentrate at the axial ends of the graphite holders in Capsules 1 and 6 (located at the top and bottom of the test train) and near the axial center in Capsules 2, 3, and 5 (in the center of the test train). The Ag-110m further tended to be concentrated around fuel stacks 1 and 3, the two stacks facing the ATR reactor core and location of higher burnup, neutron fluence, and temperatures compared with Stack 2. Detailed correlation of silver release with fuel type and irradiation temperatures is problematic at the capsule level due to the large range of temperatures experienced by individual fuel compacts in each capsule. A comprehensive Ag 110m mass balance for the capsules was performed using measured inventories of individual compacts and the inventory on the capsule components. For most capsules, the mass balance was within 11% of the predicted inventory. The Ag-110m release from individual compacts often exhibited a very large range within a particular capsule.« less

  9. Capsule endoscope localization based on computer vision technique.

    PubMed

    Liu, Li; Hu, Chao; Cai, Wentao; Meng, Max Q H

    2009-01-01

    To build a new type of wireless capsule endoscope with interactive gastrointestinal tract examination, a localization and orientation system is needed for tracking 3D location and 3D orientation of the capsule movement. The magnetic localization and orientation method produces only 5 DOF, but misses the information of rotation angle along capsule's main axis. In this paper, we presented a complementary orientation approach for the capsule endoscope, and the 3D rotation can be determined by applying computer vision technique on the captured endoscopic images. The experimental results show that the complementary orientation method has good accuracy and high feasibility.

  10. Performance evaluation of wireless communications through capsule endoscope.

    PubMed

    Takizawa, Kenichi; Aoyagi, Takahiro; Hamaguchi, Kiyoshi; Kohno, Ryuji

    2009-01-01

    This paper presents a performance evaluation of wireless communications applicable into a capsule endoscope. A numerical model to describe the received signal strength (RSS) radiated from a capsule-sized signal generator is derived through measurements in which a liquid phantom that has equivalent electrical constants is used. By introducing this model and taking into account the characteristics of its direction pattern of the capsule and propagation distance between the implanted capsule and on-body antenna, a cumulative distribution function (CDF) of the received SNR is evaluated. Then, simulation results related to the error ratio in the wireless channel are obtained. These results show that the frequencies of 611 MHz or lesser would be useful for the capsule endoscope applications from the view point of error rate performance. Further, we show that the use of antenna diversity brings additional gain to this application.

  11. Multiple internalization pathways of polyelectrolyte multilayer capsules into mammalian cells.

    PubMed

    Kastl, Lena; Sasse, Daniel; Wulf, Verena; Hartmann, Raimo; Mircheski, Josif; Ranke, Christiane; Carregal-Romero, Susana; Martínez-López, José Antonio; Fernández-Chacón, Rafael; Parak, Wolfgang J; Elsasser, Hans-Peter; Rivera Gil, Pilar

    2013-08-27

    Polyelectrolyte multilayer (PEM) capsules are carrier vehicles with great potential for biomedical applications. With the future aim of designing biocompatible, effective therapeutic delivery systems (e.g., for cancer), the pathway of internalization (uptake and fate) of PEM capsules was investigated. In particular the following experiments were performed: (i) the study of capsule co-localization with established endocytic markers, (ii) switching-off endocytotic pathways with pharmaceutical/chemical inhibitors, and (iii) characterization and quantification of capsule uptake with confocal and electron microscopy. As result, capsules co-localized with lipid rafts and with phagolysosomes, but not with other endocytic vesicles. Chemical interference of endocytosis with chemical blockers indicated that PEM capsules enter the investigated cell lines through a mechanism slightly sensitive to electrostatic interactions, independent of clathrin and caveolae, and strongly dependent on cholesterol-rich domains and organelle acidification. Microscopic characterization of cells during capsule uptake showed the formation of phagocytic cups (vesicles) to engulf the capsules, an increased number of mitochondria, and a final localization in the perinuclear cytoplasma. Combining all these indicators we conclude that PEM capsule internalization in general occurs as a combination of different sequential mechanisms. Initially, an adsorptive mechanism due to strong electrostatic interactions governs the stabilization of the capsules at the cell surface. Membrane ruffling and filopodia extensions are responsible for capsule engulfing through the formation of a phagocytic cup. Co-localization with lipid raft domains activates the cell to initiate a lipid-raft-mediated macropinocytosis. Internalization vesicles are very acidic and co-localize only with phagolysosome markers, excluding caveolin-mediated pathways and indicating that upon phagocytosis the capsules are sorted to

  12. A wireless narrowband imaging chip for capsule endoscope.

    PubMed

    Lan-Rong Dung; Yin-Yi Wu

    2010-12-01

    This paper presents a dual-mode capsule gastrointestinal endoscope device. An endoscope combined with a narrowband image (NBI), has been shown to be a superior diagnostic tool for early stage tissue neoplasms detection. Nevertheless, a wireless capsule endoscope with the narrowband imaging technology has not been presented in the market up to now. The narrowband image acquisition and power dissipation reduction are the main challenges of NBI capsule endoscope. In this paper, we present the first narrowband imaging capsule endoscope that can assist clinical doctors to effectively diagnose early gastrointestinal cancers, profited from our dedicated dual-mode complementary metal-oxide semiconductor (CMOS) sensor. The dedicated dual-mode CMOS sensor can offer white-light and narrowband images. Implementation results show that the proposed 512 × 512 CMOS sensor consumes only 2 mA at a 3-V power supply. The average current of the NBI capsule with an 8-Mb/s RF transmitter is nearly 7 ~ 8 mA that can continuously work for 6 ~ 8 h with two 1.5-V 80-mAh button batteries while the frame rate is 2 fps. Experimental results on backside mucosa of a human tongue and pig's small intestine showed that the wireless NBI capsule endoscope can significantly improve the image quality, compared with a commercial-of-the-shelf capsule endoscope for gastrointestinal tract diagnosis.

  13. Positron radiography of ignition-relevant ICF capsules

    DOE PAGES

    Williams, G. J.; Chen, Hui; Field, J. E.; ...

    2017-12-11

    Laser-generated positrons are evaluated as a probe source to radiograph in-flight ignition-relevant inertial confinement fusion capsules. Current ultraintense laser facilities are capable of producing 2 ×10 12 relativistic positrons in a narrow energy bandwidth and short time duration. Monte Carlo simulations suggest that the unique characteristics of such positrons allow for the reconstruction of both capsule shell radius and areal density between 0.002 and 2g/cm 2. The energy-downshifted positron spectrum and angular scattering of the source particles are sufficient to constrain the conditions of the capsule between preshot and stagnation. Here, we evaluate the effects of magnetic fields near themore » capsule surface using analytic estimates where it is shown that this diagnostic can tolerate line integrated field strengths of 100 T mm.« less

  14. Positron radiography of ignition-relevant ICF capsules

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Williams, G. J.; Chen, Hui; Field, J. E.

    Laser-generated positrons are evaluated as a probe source to radiograph in-flight ignition-relevant inertial confinement fusion capsules. Current ultraintense laser facilities are capable of producing 2 ×10 12 relativistic positrons in a narrow energy bandwidth and short time duration. Monte Carlo simulations suggest that the unique characteristics of such positrons allow for the reconstruction of both capsule shell radius and areal density between 0.002 and 2g/cm 2. The energy-downshifted positron spectrum and angular scattering of the source particles are sufficient to constrain the conditions of the capsule between preshot and stagnation. Here, we evaluate the effects of magnetic fields near themore » capsule surface using analytic estimates where it is shown that this diagnostic can tolerate line integrated field strengths of 100 T mm.« less

  15. Positron radiography of ignition-relevant ICF capsules

    NASA Astrophysics Data System (ADS)

    Williams, G. J.; Chen, Hui; Field, J. E.; Landen, O. L.; Strozzi, D. J.

    2017-12-01

    Laser-generated positrons are evaluated as a probe source to radiograph in-flight ignition-relevant inertial confinement fusion capsules. Current ultraintense laser facilities are capable of producing 2 × 1012 relativistic positrons in a narrow energy bandwidth and short time duration. Monte Carlo simulations suggest that the unique characteristics of such positrons allow for the reconstruction of both capsule shell radius and areal density between 0.002 and 2 g/cm2. The energy-downshifted positron spectrum and angular scattering of the source particles are sufficient to constrain the conditions of the capsule between preshot and stagnation. We evaluate the effects of magnetic fields near the capsule surface using analytic estimates where it is shown that this diagnostic can tolerate line integrated field strengths of 100 T mm.

  16. Structural Equation Modelling of Multiple Facet Data: Extending Models for Multitrait-Multimethod Data

    ERIC Educational Resources Information Center

    Bechger, Timo M.; Maris, Gunter

    2004-01-01

    This paper is about the structural equation modelling of quantitative measures that are obtained from a multiple facet design. A facet is simply a set consisting of a finite number of elements. It is assumed that measures are obtained by combining each element of each facet. Methods and traits are two such facets, and a multitrait-multimethod…

  17. Search Interface Design Using Faceted Indexing for Web Resources.

    ERIC Educational Resources Information Center

    Devadason, Francis; Intaraksa, Neelawat; Patamawongjariya, Pornprapa; Desai, Kavita

    2001-01-01

    Describes an experimental system designed to organize and provide access to Web documents using a faceted pre-coordinate indexing system based on the Deep Structure Indexing System (DSIS) derived from POPSI (Postulate based Permuted Subject Indexing) of Bhattacharyya, and the facet analysis and chain indexing system of Ranganathan. (AEF)

  18. Long-Term Developmental Changes in Children's Lower-Order Big Five Personality Facets.

    PubMed

    de Haan, Amaranta; De Pauw, Sarah; van den Akker, Alithe; Deković, Maja; Prinzie, Peter

    2017-10-01

    This study examined long-term developmental changes in mother-rated lower-order facets of children's Big Five dimensions. Two independent community samples covering early childhood (2-4.5 years; N = 365, 39% girls) and middle childhood to the end of middle adolescence (6-17 years; N = 579, 50% girls) were used. All children had the Belgian nationality. Developmental changes were examined using cohort-sequential latent growth modeling on the 18 facets of the Hierarchical Personality Inventory for Children. In early childhood, changes were mostly similar across child gender. Between 2 and 4.5 years, several facets showed mean-level stability; others changed in the direction of less Extraversion and Emotional Stability, and more Benevolence and Imagination. The lower-order facets of Conscientiousness showed opposite changes. Gender differences became more apparent from middle childhood onward for facets of all dimensions except Imagination, for which no gender differences were found. Between 6 and 17 years, same-dimension facets showed different shapes of growth. Facets that changed linearly changed mostly in the direction of less Extraversion, Benevolence, Conscientiousness, Emotional Stability, and Imagination. Changes in facets for which nonlinear growth was found generally moved in direction or magnitude during developmental transitions. This study provides comprehensive, fine-grained knowledge about personality development during the first two decades of life. © 2016 Wiley Periodicals, Inc.

  19. Capsule-odometer: a concept to improve accurate lesion localisation.

    PubMed

    Karargyris, Alexandros; Koulaouzidis, Anastasios

    2013-09-21

    In order to improve lesion localisation in small-bowel capsule endoscopy, a modified capsule design has been proposed incorporating localisation and - in theory - stabilization capabilities. The proposed design consists of a capsule fitted with protruding wheels attached to a spring-mechanism. This would act as a miniature odometer, leading to more accurate lesion localization information in relation to the onset of the investigation (spring expansion e.g., pyloric opening). Furthermore, this capsule could allow stabilization of the recorded video as any erratic, non-forward movement through the gut is minimised. Three-dimensional (3-D) printing technology was used to build a capsule prototype. Thereafter, miniature wheels were also 3-D printed and mounted on a spring which was attached to conventional capsule endoscopes for the purpose of this proof-of-concept experiment. In vitro and ex vivo experiments with porcine small-bowel are presented herein. Further experiments have been scheduled.

  20. Wireless communication link for capsule endoscope at 600 MHz.

    PubMed

    Khaleghi, A; Balasingham, I

    2015-01-01

    Simulation of a wireless communication link for a capsule endoscopy is presented for monitoring of small intestine in humans. The realized communication link includes the transmitting capsule antenna, the outside body receiving antenna and the model of the human body. The capsule antenna is designed for operating at the frequency band of 600 MHz with an impedance bandwidth of 10 MHz and omnidirectional radiation pattern. The quality of the communication link is improved by using directive antenna outside body inside matching layer for electromagnetic wave tuning to the body. The outside body antenna has circular polarization that guaranteeing the communication link for different orientations of the capsule inside intestine. It is shown that the path loss for the capsule in 60 mm from the abdomen surface varies between 37-47 dB in relation to the antenna orientation. This link can establish high data rate wireless communications for capsule endoscopy.

  1. Primate lens capsule elasticity assessed using Atomic Force Microscopy

    PubMed Central

    Ziebarth, Noël M.; Arrieta, Esdras; Feuer, William J.; Moy, Vincent T.; Manns, Fabrice; Parel, Jean-Marie

    2011-01-01

    The purpose of this project is to measure the elasticity of the human and non-human primate lens capsule at the microscopic scale using Atomic Force Microscopy (AFM). Elasticity measurements were performed using AFM on the excised anterior lens capsule from 9 cynomolgus monkey (5.9–8.0 years), 8 hamadryas baboon (2.8–10.1 years), and 18 human lenses (33–79 years). Anterior capsule specimens were obtained by performing a 5mm continuous curvilinear capsulorhexis and collecting the resulting disk of capsular tissue. To remove the lens epithelial cells the specimen was soaked in 0.1% trypsin and 0.02% EDTA for five minutes, washed, and placed on a Petri dish and immersed in DMEM. Elasticity measurements of the capsule were performed with a laboratory-built AFM system custom designed for force measurements of ophthalmic tissues. The capsular specimens were probed with an AFM cantilever tip to produce force-indentation curves for each specimen. Young’s modulus was calculated from the force-indentation curves using the model of Sneddon for a conical indenter. Young’s modulus of elasticity was 20.1–131kPa for the human lens capsule, 9.19–117kPa for the cynomolgus lens capsule, and 13.1–62.4kPa for the baboon lens capsule. Young’s modulus increased significantly with age in humans (p=0.03). The age range of the monkey and baboon samples was not sufficient to justify an analysis of age dependence. The capsule elasticity of young humans (<45 years) was not statistically different from that of the monkey and baboon. In humans, there is an increase in lens capsule stiffness at the microscale that could be responsible for an increase in lens capsule bulk stiffness. PMID:21420953

  2. Closeup View - Sigma "7" Capsule - Recovery Ship

    NASA Image and Video Library

    1962-10-03

    S62-06175 (3 Oct. 1962) --- Closeup view of the Mercury-Atlas 8 (MA-8) Sigma 7 capsule being lowered to recovery ship's deck. Navy personnel remove the floatation device before opening the capsule. Photo credit: NASA

  3. Capsule endoscopy: Current practice and future directions

    PubMed Central

    Hale, Melissa F; Sidhu, Reena; McAlindon, Mark E

    2014-01-01

    Capsule endoscopy (CE) has transformed investigation of the small bowel providing a non-invasive, well tolerated means of accurately visualising the distal duodenum, jejunum and ileum. Since the introduction of small bowel CE thirteen years ago a high volume of literature on indications, diagnostic yields and safety profile has been presented. Inclusion in national and international guidelines has placed small bowel capsule endoscopy at the forefront of investigation into suspected diseases of the small bowel. Most commonly, small bowel CE is used in patients with suspected bleeding or to identify evidence of active Crohn’s disease (CD) (in patients with or without a prior history of CD). Typically, CE is undertaken after upper and lower gastrointestinal flexible endoscopy has failed to identify a diagnosis. Small bowel radiology or a patency capsule test should be considered prior to CE in those at high risk of strictures (such as patients known to have CD or presenting with obstructive symptoms) to reduce the risk of capsule retention. CE also has a role in patients with coeliac disease, suspected small bowel tumours and other small bowel disorders. Since the advent of small bowel CE, dedicated oesophageal and colon capsule endoscopes have expanded the fields of application to include the investigation of upper and lower gastrointestinal disorders. Oesophageal CE may be used to diagnose oesophagitis, Barrett’s oesophagus and varices but reliability in identifying gastroduodenal pathology is unknown and it does not have biopsy capability. Colon CE provides an alternative to conventional colonoscopy for symptomatic patients, while a possible role in colorectal cancer screening is a fascinating prospect. Current research is already addressing the possibility of controlling capsule movement and developing capsules which allow tissue sampling and the administration of therapy. PMID:24976712

  4. Inadvertent trypan blue posterior capsule staining during cataract surgery.

    PubMed

    Burkholder, Bryn M; Srikumaran, Divya; Nanji, Afshan; Lee, Bryan; Weinberg, Robert S

    2013-04-01

    To report 5 cases of inadvertent posterior capsule staining with trypan blue during phacoemulsification. Retrospective, observational case series. Five cases of posterior capsule staining with trypan blue were identified from cataract surgeries performed at an academic institution. All 5 eyes underwent phacoemulsification with use of iris retractors. The surgical videos from each case were reviewed to better understand the mechanisms and risk factors for posterior capsule staining with trypan blue and techniques to avoid this complication. No eyes had clinical evidence of zonular pathology during their preoperative examination. Only 1 patient reported a possible childhood history of trauma to both eyes. One eye had uveitis, requiring posterior synechialysis. All 5 cases involved the use of iris retractors. No other intraoperative complications occurred, and the intraocular lens was successfully placed in the capsular bag in all cases. All eyes had resolution of posterior capsule staining by postoperative day 8. Inadvertent posterior capsule staining with trypan blue can occur in eyes that appear structurally normal. The use of iris retractors may facilitate posterior capsule staining by allowing the posterior flow of trypan blue under the iris and through the zonules to the posterior capsule. Surgeons should consider techniques to minimize the risk of posterior capsule staining, particularly in cases involving the use of iris retractors. Copyright © 2013 Elsevier Inc. All rights reserved.

  5. Aspiration of capsule endoscope and successful bronchoscopic extraction.

    PubMed

    Girdhar, Ankur; Usman, Faisal; Bajwa, Abubakr

    2012-10-01

    Capsule endoscopy is a novel tool for the diagnosis of small intestinal disorders. Recently, a new complication of the procedure in the form of the capsule's aspiration into the lungs has been reported. The aspiration of capsule endoscope can lead to a variety of complications including respiratory failure. A low threshold to suspect this complication and urgent bronchoscopic extraction in appropriate patients can prevent serious sequelae.

  6. Bronchial Aspiration of Capsule Endoscope.

    PubMed

    Buscot, Matthieu; Leroy, Sylvie; Pradelli, Johanna; Chaabane, Nouha; Hebuterne, Xavier; Marquette, Charles-Hugo; Filippi, Jerôme

    2017-01-01

    Capsule endoscope aspiration is an increasingly reported complication, potentially responsible for respiratory distress and asphyxia. This adverse event is primarily managed by rigid bronchoscopy when spontaneous expulsion does not occur. This complication is all the more detrimental to patients as it can delay or jeopardize further digestive exploration. We report direct repositioning of the capsule in the stomach at the same time as bronchoscopy, thus making second-line gastrointestinal endoscopy needless. © 2017 S. Karger AG, Basel.

  7. Investigating facets of personality in adult pathological gamblers with ADHD

    PubMed Central

    Davtian, Margarit; Reid, Rory C; Fong, Timothy W

    2012-01-01

    SUMMARY The present study explored facets of personality in a sample of pathological gamblers with ADHD (n = 52) and without ADHD (n = 43). Participants were assessed for psychopathology and gambling disorders using the Mini International Neuropsychiatric Interview, the National Opinion Research Center DSM Screen for Gambling Problems, and the Adult ADHD Self-Report Scale. Facets of personality were assessed using the NEO Personality Inventory–Revised. Group differences emerged across several facets of personality when analyzed using multivariate statistics. Although both groups experienced difficulties in several areas compared with norming data (e.g., greater depression, higher impulsivity, lower self-esteem and lower self-discipline), these facets of personality were more pronounced in pathological gamblers with ADHD. Most notable among these differences are tendencies for gamblers with ADHD to experience greater levels of emotional instability, interpersonal sensitivity and stress proneness. Pathological gamblers with ADHD also appear to experience lower self-esteem, greater difficulty being assertive and lower levels of self-discipline. Surprisingly, both groups were comparable on facets of impulsivity. These findings suggest that pathological gamblers diagnosed with adult ADHD may experience additional challenges compared with pathological gamblers without ADHD. PMID:22815658

  8. Evolving faceted surfaces: From continuum modeling, to geometric simulation, to mean-field theory

    NASA Astrophysics Data System (ADS)

    Norris, Scott A.

    We first consider the directional solidification, in two dimensions, of a dilute binary alloy having a large anisotropy of surface energy, where the sample is pulled in a high-energy direction such that the planar state is thermodynamically prohibited. Analyses including reduction of dynamics, matched asymptotic analysis, and energy minimization are used to show that the interface assumes a faceted profile with small wavelength. Questions on stability and other dynamic behavior lead to the derivation of a facet-velocity law. This shows the that faceted steady solutions are stable in the absence of constitutional supercooling, while in its presence, coarsening replaces cell formation as the mechanism of instability. We next proceed to introduce a computational-geometry tool which, given a facet-velocity law, performs large-scale simulations of fully-faceted coarsening surfaces, first in the special case with only three allowed facet orientations (threefold symmetry), and then for arbitrary surfaces. Topological events including coarsening are comprehensively considered, and are treated explicitly by our method using both a priori knowledge of event outcomes and a novel graph-rewriting algorithm. While careful attention must be paid to both non-unique topological events and the imposition of a discrete time-stepping scheme, the resulting method allows rapid simulation of large surfaces and easy extraction of statistical data. Example statistics are provided for the threefold case based on simulations totaling one million facets. Finally, a mean-field theory is developed for the scale-invariant length distributions observed during the coarsening of one-dimensional faceted surfaces. This theory closely follows the LSW theory of Ostwald ripening in two-phase systems, but the mechanism of coarsening in faceted surfaces requires the derivation of additional terms to model the coalescence of facets. The model is solved by the exponential distribution, but agreement with

  9. Facet tropism and interfacet shape in the thoracolumbar vertebrae: characterization and biomechanical interpretation.

    PubMed

    Masharawi, Youssef; Rothschild, Bruce; Salame, Khalil; Dar, Gali; Peleg, Smadar; Hershkovitz, Israel

    2005-06-01

    Thoracolumbar facet and interfacet linear dimensions were measured and analyzed. To characterize and analyze the thoracolumbar facet and interfacet size and shape in relation to gender, ethnic group, and age and to detect the extent of normal facet tropism along the thoracolumbar spine. Knowledge on facet tropism and interfacet shape is limited in the literature as most data are based on 2-dimensional measurements, small samples, or isolated vertebrae. Facet shape as represented by width, length, width/length ratio and interfacet distances was obtained directly from dry vertebrae of 240 adult human spines. The specimen's osteologic material is part of the Hamann-Todd Osteological Collection housed at the Cleveland Museum of Natural History, Cleveland, OH. A total of 4080 vertebrae (T1-L5) from the vertebral columns of individuals 20 to 80 years of age were measured, using a Microscribe 3-dimensional apparatus (Immersion Co., San Jose, CA). Data were recorded directly on computer software. Statistical analysis included paired t tests and ANOVA. A significant correlation was found between all thoracolumbar facet dimensions and an individual's height and weight. Facet tropism is a major characteristic of the thoracolumbar spine, the left being longer in the thorax while the right is longer in the lumbar. In general, facet size is age-independent and greater in males compared with females with a significant ethnic component. Facet length is similar for all thoracic vertebrae, whereas it sharply and continuously increases in the lumbar vertebrae. Facet dimension manifests a bipolar distribution along the thoracolumbar vertebrae. Width/length ratio indicates that facets are longer than wider for most verte-brae. The interarticular area manifests a marked inverted trapezoidal shape at T1-T2, a rectangular shape at T3-L3, and an ordinary trapezoidal shape at L4-L5. Facet tropism is a normal characteristic in humans, yet it varies along the thoracolumbar spine.

  10. Therapeutic Application of Phage Capsule Depolymerases against K1, K5, and K30 Capsulated E. coli in Mice.

    PubMed

    Lin, Han; Paff, Matthew L; Molineux, Ian J; Bull, James J

    2017-01-01

    Capsule depolymerase enzymes offer a promising class of new antibiotics. In vivo studies are encouraging but it is unclear how well this type of phage product will generalize in therapeutics, or whether different depolymerases against the same capsule function similarly. Here, in vivo efficacy was tested using cloned bacteriophage depolymerases against Escherichia coli strains with three different capsule types: K1, K5, and K30. When treating infections with the cognate capsule type in a mouse thigh model, the previously studied K1E depolymerase rescued poorly, whereas K1F, K1H, K5, and K30 depolymerases rescued well. K30 gp41 was identified as the catalytically active protein. In contrast to the in vivo studies, K1E enzyme actively degraded K1 capsule polysaccharide in vitro and sensitized K1 bacteria to serum killing. The only in vitro correlate of poor K1E performance in vivo was that the purified enzyme did not form the expected trimer. K1E appeared as an 18-mer which might limit its in vivo distribution. Overall, depolymerases were easily identified, cloned from phage genomes, and as purified proteins they proved generally effective.

  11. Spheroidal and conical shapes of ferrofluid-filled capsules in magnetic fields

    NASA Astrophysics Data System (ADS)

    Wischnewski, Christian; Kierfeld, Jan

    2018-04-01

    We investigate the deformation of soft spherical elastic capsules filled with a ferrofluid in external uniform magnetic fields at fixed volume by a combination of numerical and analytical approaches. We develop a numerical iterative solution strategy based on nonlinear elastic shape equations to calculate the stretched capsule shape numerically and a coupled finite element and boundary element method to solve the corresponding magnetostatic problem and employ analytical linear response theory, approximative energy minimization, and slender-body theory. The observed deformation behavior is qualitatively similar to the deformation of ferrofluid droplets in uniform magnetic fields. Homogeneous magnetic fields elongate the capsule and a discontinuous shape transition from a spheroidal shape to a conical shape takes place at a critical field strength. We investigate how capsule elasticity modifies this hysteretic shape transition. We show that conical capsule shapes are possible but involve diverging stretch factors at the tips, which gives rise to rupture for real capsule materials. In a slender-body approximation we find that the critical susceptibility above which conical shapes occur for ferrofluid capsules is the same as for droplets. At small fields capsules remain spheroidal and we characterize the deformation of spheroidal capsules both analytically and numerically. Finally, we determine whether wrinkling of a spheroidal capsule occurs during elongation in a magnetic field and how it modifies the stretching behavior. We find the nontrivial dependence between the extent of the wrinkled region and capsule elongation. Our results can be helpful in quantitatively determining capsule or ferrofluid material properties from magnetic deformation experiments. All results also apply to elastic capsules filled with a dielectric liquid in an external uniform electric field.

  12. The transport of wear particles in the prosthetic hip joint: a computational fluid dynamics investigation.

    PubMed

    Hölzer, Andreas; Schröder, Christian; Woiczinski, Matthias; Sadoghi, Patrick; Müller, Peter E; Jansson, Volkmar

    2012-02-02

    The joint fluid mechanics and transport of wear particles in the prosthetic hip joint were analyzed for subluxation and flexion motion using computational fluid dynamics (CFD). The entire joint space including a moving capsule boundary was considered. It was found that particles suspended in the joint space are drawn into the joint gap between prosthesis cup and head during subluxation, which was also documented by Lundberg et al. (2007; Journal of Biomechanics 40, 1676-1685), however, wear particles remain in the joint gap. Wear particles leave the joint gap during flexion and can finally migrate to the proximal boundaries including the acetabular bone, where the particle deposition can cause osteolysis according to the established literature. Thus, the present study supports the theory of polyethylene wear particle induced osteolysis of the acetabular bone as a major factor in the loosening of hip prosthesis cups. Copyright © 2011 Elsevier Ltd. All rights reserved.

  13. Development of three-layered rumen escapable capsules for cattle

    PubMed Central

    SEYAMA, Tomohiro; HIRAYASU, Hirofumi; YAMAWAKI, Kenji; ADACHI, Takuhiko; SUGIMOTO, Takayuki; KASAI, Koji

    2016-01-01

    A new rumen escapable tool is presented for cattle in prospect of developing medical treatment or supplementing trace elements for disease prevention. This tool consists of a three-layered capsule that dissolves in the lower digestive tract, but not in the rumen. The capsule was manufactured by capsule-forming techniques through the use of liquid surface tension. This method does not involve high-temperature treatment, so the capsule can contain not only lipophilic substances but also hydrophilic or heat-sensitive substances. Furthermore, the capsule has a specific gravity of 1.3 and diameter of 6.0 mm, which were previously shown to be appropriate to avoid rumination. The objective of this study was to confirm the effectiveness of the capsule pertinent to rumen escaping. In order to validate rumen escape, capsules containing 30 g of water-soluble vitamin (thiamine hydrochloride) per head were administered to four lactating cows assigned in a crossover trial. In the group administered encapsulated thiamine hydrochloride, blood thiamine levels increased from 12.4 ± 1.03 ng/ml before administration to 54.8 ± 2.21 ng/ml at 6 hr following administration, whereas the level remained at 13.3 ± 2.05 ng/ml in the control group administered via aqueous solution. This indicates that the three-layered capsules passed through the rumen and dissolved in the lower digestive tract, thus functioning as a rumen escapable tool. PMID:27546371

  14. Unusual Internal Astigmatism Due to Severe Capsule Contraction Syndrome.

    PubMed

    Zéboulon, Pierre; Gatinel, Damien

    2018-01-01

    To describe a case of severe capsule contraction syndrome causing significant astigmatism due to intraocular lens (IOL) folding. Case report. Capsule fibrosis and contraction resulted in bending of the hydrophilic IOL along its long axis. Anterior Nd:YAG capsulotomy resolved the situation and restored the patient's visual acuity. Hydrophilic IOLs are more susceptible to capsule contraction due to the increased flexibility of highly hydrated materials. They should be avoided in patients at risk of capsule contraction to prevent ocular complications. [J Refract Surg. 2018;34(1):65-67.]. Copyright 2018, SLACK Incorporated.

  15. Extraversion and psychopathology: A facet-level analysis.

    PubMed

    Watson, David; Stasik, Sara M; Ellickson-Larew, Stephanie; Stanton, Kasey

    2015-05-01

    The goal of this study was to explicate how the lower order facets of extraversion are related to psychopathology. We used a "bottom-up" approach in which specific extraversion scales from 3 comprehensive personality inventories were used to model these facets as latent factors. We collected both self-report and interview measures of a broad range of psychopathology from a large community sample. Replicating previous findings using a similar approach (Naragon-Gainey & Watson, 2014; Naragon-Gainey, Watson, & Markon, 2009), structural analyses yielded four factors: Positive Emotionality, Sociability, Assertiveness, and Experience Seeking. Scores on these latent dimensions were related to psychopathology in correlational analyses and in two sets of regressions (the first series used the four facets as predictors; the second included composite scores on the other Big Five domains as additional predictors). These results revealed a striking level of specificity. As predicted, Positive Emotionality displayed especially strong negative links to depressive symptoms and diagnoses. Sociability also was negatively related to psychopathology, showing particularly strong associations with indicators of social dysfunction and the negative symptoms of schizotypy (i.e., social anxiety, social aloofness, and restricted affectivity). Assertiveness generally had weak associations at the bivariate level but was negatively related to social anxiety and was positively correlated with some forms of externalizing. Finally, Experience Seeking had substantial positive associations with a broad range of indicators related to externalizing and bipolar disorder; it also displayed negative links to agoraphobia. These differential correlates demonstrate the importance of examining personality-psychopathology relations at the specific facet level. (c) 2015 APA, all rights reserved).

  16. Enhanced photoactivity of BiPO4/(001) facet-dominated square BiOBr flakes by combining heterojunctions with facet engineering effects

    NASA Astrophysics Data System (ADS)

    Shi, Jingzhi; Meng, Xiangying; Hao, Mengjian; Cao, Zhenzhu; He, Weiyan; Gao, Yanfang; Liu, Jinrong

    2018-02-01

    In this study, BiPO4/highly (001) facet exposed square BiOBr flake heterojunction photocatalysts with different molar ratios were fabricated via a two-step method. The synergetic effect of the heterojunction and facet engineering was systematically investigated. The physicochemical properties of the BiPO4/square BiOBr flake composites were characterized based on X-ray diffraction, field emission scanning electron microscopy, transmission electron microscopy, Brunauer-Emmett-Teller method, X-ray photoelectron spectroscopy, ultraviolet-visible diffuse reflectance spectra, photoluminescence, electrochemical impedance spectroscopy, and the photocurrent response. The BiPO4/square BiOBr flake heterojunction photocatalyst exhibited much higher photocatalytic performance compared with the individual BiPO4 and BiOBr. In particular, the BiPO4/BiOBr composite where P/Br = 1/3 exhibited the highest photocatalytic activity. The intensified separation of photoinduced charges at the p-n heterojunction between the BiPO4 nanoparticle and (001) facet of BiOBr was mainly responsible for the enhanced photoactivity.

  17. [Does the French Big Five Inventory evaluate facets other than the Big Five factors?

    PubMed

    Courtois, R; Petot, J-M; Lignier, B; Lecocq, G; Plaisant, O

    2017-03-29

    The Big Five Inventory (BFI) developed by John et al. (1991) is one of the most widely accepted tools for assessing dimensions of personality. It comprises 44 items that assess five broad dimensions of personality (the Big Five Factors): Extraversion, Agreeableness, Conscientiousness, Neuroticism and Openness to experience. Based on correlations with the facets described in the NEO Personality Inventory Revised (NEO PI-R), another Big Five assessment tool with 240 items and 6 facets per dimension, Soto and John (2009) showed that the dimensions in the BFI could be divided into two facets each (ten facets altogether). These results are in line with those of DeYoung et al. (2007), who ran factorial analyses with all the NEO PI-R facets and the International Personality Item Pool (IPIP) and identified ten intermediate factors (between facets and dimensions) which they called "aspects" (two per dimension). The goal of the present study is to investigate the ten facets described by Soto and John in a French sample, using the French version of the BFI (BFI-Fr), which has good psychometric properties, and to check whether the pattern of correlations of these facets with the NEO PI-R match those of the American version. We created three groups. The first comprised 360 students from the Institut libre d'éducation physique supérieure (ILEPS) and Tours University (psychology undergraduates). Participants (mean age 21.1 years±2.30; 58% women) completed the BFI-Fr and the NEO PI-R. The second comprised 142 psychology students from Tours University (mean age 20.6 years±1.78; 81% women); they completed the BFI-Fr twice, two weeks apart (test and retest). The third comprised 252 psychology students from Paris-Nanterre University (mean age 23 years±4.2; 89% women) who described a total of 405 people they knew well (mean age 35.2±10.8; 49% women) using the peer-report format of the BFI-Fr. In the self-report format, eight of Soto and John's ten aspects had acceptable internal

  18. Albumin/asparaginase capsules prepared by ultrasound to retain ammonia.

    PubMed

    Tinoco, Ana; Ribeiro, Artur; Oliveira, César; Parpot, Pier; Gomes, Andreia; Cavaco-Paulo, Artur

    2016-11-01

    Asparaginase reduces the levels of asparagine in blood, which is an essential amino acid for the proliferation of lymphoblastic malign cells. Asparaginase converts asparagine into aspartic acid and ammonia. The accumulation of ammonia in the bloodstream leads to hyperammonemia, described as one of the most significant side effects of asparaginase therapy. Therefore, there is a need for asparaginase formulations with the potential to reduce hyperammonemia. We incorporated 2 % of therapeutic enzyme in albumin-based capsules. The presence of asparaginase in the interface of bovine serum albumin (BSA) capsules showed the ability to hydrolyze the asparagine and retain the forming ammonia at the surface of the capsules. The incorporation of Poloxamer 407 in the capsule formulation further increased the ratio aspartic acid/ammonia from 1.92 to 2.46 (and 1.10 from the free enzyme), decreasing the levels of free ammonia. This capacity to retain ammonia can be due to electrostatic interactions and retention of ammonia at the surface of the capsules. The developed BSA/asparaginase capsules did not cause significant cytotoxic effect on mouse leukemic macrophage cell line RAW 264.7. The new BSA/asparaginase capsules could potentially be used in the treatment of acute lymphoblastic leukemia preventing hyperammonemia associated with acute lymphoblastic leukemia (ALL) treatment with asparaginase.

  19. Analysing intracellular deformation of polymer capsules using structured illumination microscopy

    NASA Astrophysics Data System (ADS)

    Chen, Xi; Cui, Jiwei; Sun, Huanli; Müllner, Markus; Yan, Yan; Noi, Ka Fung; Ping, Yuan; Caruso, Frank

    2016-06-01

    Understanding the behaviour of therapeutic carriers is important in elucidating their mechanism of action and how they are processed inside cells. Herein we examine the intracellular deformation of layer-by-layer assembled polymer capsules using super-resolution structured illumination microscopy (SIM). Spherical- and cylindrical-shaped capsules were studied in three different cell lines, namely HeLa (human epithelial cell line), RAW264.7 (mouse macrophage cell line) and differentiated THP-1 (human monocyte-derived macrophage cell line). We observed that the deformation of capsules was dependent on cell line, but independent of capsule shape. This suggests that the mechanical forces, which induce capsule deformation during cell uptake, vary between cell lines, indicating that the capsules are exposed to higher mechanical forces in HeLa cells, followed by RAW264.7 and then differentiated THP-1 cells. Our study demonstrates the use of super-resolution SIM in analysing intracellular capsule deformation, offering important insights into the cellular processing of drug carriers in cells and providing fundamental knowledge of intracellular mechanobiology. Furthermore, this study may aid in the design of novel drug carriers that are sensitive to deformation for enhanced drug release properties.Understanding the behaviour of therapeutic carriers is important in elucidating their mechanism of action and how they are processed inside cells. Herein we examine the intracellular deformation of layer-by-layer assembled polymer capsules using super-resolution structured illumination microscopy (SIM). Spherical- and cylindrical-shaped capsules were studied in three different cell lines, namely HeLa (human epithelial cell line), RAW264.7 (mouse macrophage cell line) and differentiated THP-1 (human monocyte-derived macrophage cell line). We observed that the deformation of capsules was dependent on cell line, but independent of capsule shape. This suggests that the mechanical forces

  20. The capsule of the fungal pathogen Cryptococcus neoformans

    PubMed Central

    Zaragoza, Oscar; Rodrigues, Marcio L.; De Jesus, Magdia; Frases, Susana; Dadachova, Ekaterina; Casadevall, Arturo

    2009-01-01

    The capsule of the fungal pathogen Cryptococcus neoformans has been studied extensively in recent decades, and a large body of information is now available to the scientific community. Well-known aspects of the capsule include its structure, antigenic properties and its function as a virulence factor. The capsule is composed primarily of two polysaccharides, glucuronoxylomannan (GXM) and galactoxylomannan (GalXM), in addition to a smaller proportion of mannoproteins (MP). Most of the studies on the composition of the capsule have focused on GXM, which comprises more than 90% of the capsule's polysaccharide mass. It is GalXM, however, that is of particular scientific interest because of its immunological properties. The molecular structure of these polysaccharides is very complex and has not yet been fully elucidated. Both GXM and GalXM are high molecular mass polymers with the mass of GXM equaling roughly 10 times that of GalXM. Recent findings suggest, however, that the actual Mw might be different to what it has traditionally been thought to be. In addition to their structural roles in the polysaccharide capsule, these molecules have been associated with many deleterious effects on the immune response. Capsular components are therefore considered key virulence determinants in Cryptococcus neoformans, which has motivated their use in vaccines and made them targets for monoclonal antibody treatments. In this review we will provide an update on the current knowledge of the C. neoformans capsule, covering aspects related to its structure, synthesis, and particularly, its role as a virulence factor. PMID:19426855

  1. The mechanoreceptors of the costo-vertebral joints

    PubMed Central

    Godwin-Austen, R. B.

    1969-01-01

    1. Unitary recording in the thoracic dorsal roots of mechanoreceptor discharges from the costo-vertebral joints was carried out in the cat and rabbit. Criteria for the identification of costo-vertebral joint mechanoreceptors were established. 2. The majority of rib joint mechanoreceptors are slowly adapting and fifty-three such receptors were studied. Five rapidly adapting receptors were also identified. 3. The responses of these receptors have been correlated with rib position and movement. The slowly adapting receptors gave a monotonic response to different rib positions. 72% showed an increase of discharge rate with displacements towards expiratory rib positions. 4. In response to manually imposed rib movements slowly adapting joint mechanoreceptors gave a dynamic response which was directly related to the velocity of the movement and adapted within 2 sec. The movements of breathing produced a corresponding alteration of the discharge frequency of the slowly adapting receptors. 5. Slowly adapting receptors were localized to the capsule of the costo-transverse joint by probing. They responded to increased intra-articular pressure with an increase of discharge rate and were silenced by intra-articular lignocaine, 0·4%. 6. Rapidly adapting joint mechanoreceptors responded to rib movement with a brief burst of discharges. 7. The rib joint mechanoreceptors signal rib joint position, and the direction and velocity of rib movement. It is suggested that these afferent discharges provide the basis for the perception of respiratory movements of the chest. The significance of these receptors to the `sense of effort' resulting from a resistance to breathing is discussed. PMID:5789947

  2. Tag gas capsule with magnetic piercing device

    DOEpatents

    Nelson, Ira V.

    1976-06-22

    An apparatus for introducing a tag (i.e., identifying) gas into a tubular nuclear fuel element. A sealed capsule containing the tag gas is placed in the plenum in the fuel tube between the fuel and the end cap. A ferromagnetic punch having a penetrating point is slidably mounted in the plenum. By external electro-magnets, the punch may be caused to penetrate a thin rupturable end wall of the capsule and release the tag gas into the fuel element. Preferably the punch is slidably mounted within the capsule, which is in turn loaded as a sealed unit into the fuel element.

  3. 2016 FACET-II Science Workshop Summary Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hogan, Mark J.

    The second in a series of FACET-II Science Workshops was held at SLAC National Accelerator Laboratory on October 17-19, 2016 [1]. The workshop drew thirty-five participants from eighteen different institutions including CERN, DESY, Ecole Polytechnique, FNAL, JAI, LBNL, LLNL, Radiabeam, Radiasoft, SLAC, Stony Brook, Strathclyde, Tech-X, Tsinghua, UC Boulder, UCLA and UT Austin. The 2015 workshop [2, 3] helped prioritize research directions for FACET-II. The 2016 workshop was focused on understanding what improvements are needed at the facility to support the next generation of experiments. All presentations are linked to the workshop website as a permanent record.

  4. Alternative method for enteric coating of HPMC capsules resulting in ready-to-use enteric-coated capsules.

    PubMed

    Huyghebaert, Nathalie; Vermeire, An; Remon, Jean Paul

    2004-04-01

    The aim of this study was to develop an alternative method for enteric coating of HPMC capsules that avoids the sealing step before coating, resulting in ready-to-use enteric-coated capsules for the use in retail or hospital pharmacy or R&D sections of pharmaceutical industry and for the production of enteric-coated heat and moisture sensitive biomaterials. HPMC caps and bodies 00 (Vcaps, Capsugel) were coated separately in a fluid bed apparatus prior to filling (GPCG-1, Glatt) with Eudragit L30D-55 or Eudragit FS 30 D (Röhm), Aqoat AS-HF (Shin-Etsu) and Sureteric (Colorcon), using an optimised coating process. The coated bodies were filled and closed with the coated caps without encountering problems of coating damage. The release in 0.1N HCl after 2h from capsules coated with Eudragit L30D-55, Eudragit FS 30 D, Aqoat AS-HF and Sureteric was 0.6+/-.03, 0.6+/-0.3, 1.2+/-0.2 and 7.3+/-1.9%, respectively. The alternative method was reproducible and offered a way to overcome the time-consuming and expensive sealing step required using the conventional coating procedure. The obtained enteric-coated HPMC capsules can be stored (un)-filled for at least 6 months without loosing enteric properties.

  5. Au-Assisted Substrate-Faceting for Inclined Nanowire Growth.

    PubMed

    Kang, Jung-Hyun; Krizek, Filip; Zaluska-Kotur, Magdalena; Krogstrup, Peter; Kacman, Perla; Beidenkopf, Haim; Shtrikman, Hadas

    2018-06-12

    We study the role of gold droplets in the initial stage of nanowire growth via the vapor-liquid-solid method. Apart from serving as a collections center for growth species, the gold droplets carry an additional crucial role that necessarily precedes the nanowire emergence, that is, they assist the nucleation of nanocraters with strongly faceted {111}B side walls. Only once these facets become sufficiently large and regular, the gold droplets start nucleating and guiding the growth of nanowires. We show that this dual role of the gold droplets can be detected and monitored by high-energy electron diffraction during growth. Moreover, gold-induced formation of craters and the onset of nanowires growth on the {111}B facets inside the craters are confirmed by the results of Monte Carlo simulations. The detailed insight into the growth mechanism of inclined nanowires will help to engineer new and complex nanowire-based device architectures.

  6. Coracoclavicular joint: osteologic study of 1020 human clavicles

    PubMed Central

    Gumina, S; Salvatore, M; De Santis, P; Orsina, L; Postacchini, F

    2002-01-01

    We examined 1020 dry clavicles from cadavers of Italian origin to determine the prevalence of the coracoclavicular joint (ccj), a diarthrotic synovial joint occasionally present between the conoid tubercle of the clavicle and the superior surface of the horizontal part of the coracoid process. Five hundred and nine clavicles from individuals of different ages were submitted to X-ray examination. Using radiography, we measured the entire length and the index of sinuosity of the anterior lateral curve, on which the distance between the conoid tubercle and the coracoid process depends. We also used radiography to record the differences in prevalence of arthritis in two neighbouring joints, the acromioclavicular and sternoclavicular joints. Of the 1020 clavicles, eight (0.8%) displayed the articular facet of the ccj. No statistical correlation was found between clavicular length and the index of sinuosity of the anterior lateral curve. The prevalence of arthritis in clavicles with ccj was higher than that revealed in clavicles without ccj. The prevalence of ccj in the studied clavicles is lower than that observed in Asian cohorts. Furthermore, ccj is not conditioned by either length or sinuosity of the anterior lateral curve of the clavicle. Finally, the assumption that ccj is a predisposing factor for degenerative changes of neighbouring joints is statistically justified. PMID:12489763

  7. Capsule Shimming Developments for National Ignition Facility (NIF) Hohlraum Asymmetry Experiments

    DOE PAGES

    Rice, Neal G.; Vu, M.; Kong, C.; ...

    2017-12-20

    Capsule drive in National Ignition Facility (NIF) indirect drive implosions is generated by x-ray illumination from cylindrical hohlraums. The cylindrical hohlraum geometry is axially symmetric but not spherically symmetric causing capsule-fuel drive asymmetries. We hypothesize that fabricating capsules asymmetric in wall thickness (shimmed) may compensate for drive asymmetries and improve implosion symmetry. Simulations suggest that for high compression implosions Legendre mode P 4 hohlraum flux asymmetries are the most detrimental to implosion performance. General Atomics has developed a diamond turning method to form a GDP capsule outer surface to a Legendre mode P 4 profile. The P 4 shape requiresmore » full capsule surface coverage. Thus, in order to avoid tool-lathe interference flipping the capsule part way through the machining process is required. This flipping process risks misalignment of the capsule causing a vertical step feature on the capsule surface. Recent trials have proven this step feature height can be minimized to ~0.25 µm.« less

  8. Scaling effects in spiral capsule robots.

    PubMed

    Liang, Liang; Hu, Rong; Chen, Bai; Tang, Yong; Xu, Yan

    2017-04-01

    Spiral capsule robots can be applied to human gastrointestinal tracts and blood vessels. Because of significant variations in the sizes of the inner diameters of the intestines as well as blood vessels, this research has been unable to meet the requirements for medical applications. By applying the fluid dynamic equations, using the computational fluid dynamics method, to a robot axial length ranging from 10 -5 to 10 -2  m, the operational performance indicators (axial driving force, load torque, and maximum fluid pressure on the pipe wall) of the spiral capsule robot and the fluid turbulent intensity around the robot spiral surfaces was numerically calculated in a straight rigid pipe filled with fluid. The reasonableness and validity of the calculation method adopted in this study were verified by the consistency of the calculated values by the computational fluid dynamics method and the experimental values from a relevant literature. The results show that the greater the fluid turbulent intensity, the greater the impact of the fluid turbulence on the driving performance of the spiral capsule robot and the higher the energy consumption of the robot. For the same level of size of the robot, the axial driving force, the load torque, and the maximum fluid pressure on the pipe wall of the outer spiral robot were larger than those of the inner spiral robot. For different requirements of the operating environment, we can choose a certain kind of spiral capsule robot. This study provides a theoretical foundation for spiral capsule robots.

  9. Mechanical characterization of capsule properties using abrupt-step channels

    NASA Astrophysics Data System (ADS)

    Salsac, Anne-Virginie; Le Goff, Anne; Kaoui, Badr; Barthè-Biesel, Dominique; Biomechanics; Bioengineering Lab Team

    2017-11-01

    Capsules consisting of a liquid droplet enclosed by a thin polymerized membrane are commonly encountered in nature (cells) or in industrial process (pharmaceutical, cosmetic or food products). The mechanical properties of the capsule wall are essential to guarantee the particle integrity and release of the internal contents when and where necessary. The difficulty is to assess the mechanical properties of the thin membrane. We will show how abrupt-step channels can be used to identify the membrane viscoelastic properties and point of rupture. This can be achieved by using a channel presenting a step change in cross-section and inverting the direction of the flow of the capsule suspension within the tube. To deduce information on the viscoelasticity, we will exploit the relaxation of the capsules as they flow through the expansion. To study membrane rupture, we will instead invert the channel, block the capsules at the neck of the constriction and determine the pressure difference needed for breakup. All the experiments will be conducted on initially spherical capsules with a thin cross-linked protein membrane for a proof of concept.

  10. Anterior capsule tear after laser iridotomy complicating phacoemulsification

    PubMed Central

    Vivien Cherng Hui, Yip; Sanjay, Srinivasan; Benjamin Chong-Ming, Chang

    2011-01-01

    A 70-year-old Indian lady had a history of bilateral laser peripheral iridotomy (LPI) for primary angle closure. Subsequently she developed cataract in both the eyes. Right eye cataract surgery was complicated by an anterior capsule rupture, which was discovered intra-operatively at the site of the LPI. Trypan blue was used to stain the anterior capsule to delineate the anterior capsule defect. An attempt at continuous curvilinear capsulorhexis was unsuccessful, and the anterior capsulotomy was completed with scissors. To the best of our knowledge the surgical management of cataract in the presence of anterior capsule rupture as a result of LPI has not been reported. Awareness of this potential complication of LPI will aid in planning for successful phacoemulsification cataract surgery. PMID:23960943

  11. Antioxidant functionalized polymer capsules to prevent oxidative stress.

    PubMed

    Larrañaga, Aitor; Isa, Isma Liza Mohd; Patil, Vaibhav; Thamboo, Sagana; Lomora, Mihai; Fernández-Yague, Marc A; Sarasua, Jose-Ramon; Palivan, Cornelia G; Pandit, Abhay

    2018-02-01

    Polymeric capsules exhibit significant potential for therapeutic applications as microreactors, where the bio-chemical reactions of interest are efficiently performed in a spatial and time defined manner due to the encapsulation of an active biomolecule (e.g., enzyme) and control over the transfer of reagents and products through the capsular membrane. In this work, catalase loaded polymer capsules functionalized with an external layer of tannic acid (TA) are fabricated via a layer-by-layer approach using calcium carbonate as a sacrificial template. The capsules functionalised with TA exhibit a higher scavenging capacity for hydrogen peroxide and hydroxyl radicals, suggesting that the external layer of TA shows intrinsic antioxidant properties, and represents a valid strategy to increase the overall antioxidant potential of the developed capsules. Additionally, the hydrogen peroxide scavenging capacity of the capsules is enhanced in the presence of the encapsulated catalase. The capsules prevent oxidative stress in an in vitro inflammation model of degenerative disc disease. Moreover, the expression of matrix metalloproteinase-3 (MMP-3), and disintegrin and metalloproteinase with thrombospondin motif-5 (ADAMTS-5), which represents the major proteolytic enzymes in intervertebral disc, are attenuated in the presence of the polymer capsules. This platform technology exhibits potential to reduce oxidative stress, a key modulator in the pathology of a broad range of inflammatory diseases. Oxidative stress damages important cell structures leading to cellular apoptosis and senescence, for numerous disease pathologies including cancer, neurodegeneration or osteoarthritis. Thus, the development of biomaterials-based systems to control oxidative stress has gained an increasing interest. Herein, polymer capsules loaded with catalase and functionalized with an external layer of tannic acid are fabricated, which can efficiently scavenge important reactive oxygen species (i

  12. Flake-shell capsules: adjustable inorganic structures.

    PubMed

    Ji, Qingmin; Guo, Chunyan; Yu, Xiaoyan; Ochs, Christopher J; Hill, Jonathan P; Caruso, Frank; Nakazawa, Hiromoto; Ariga, Katsuhiko

    2012-08-06

    Structure-adjustable capsules are fabricated from inorganic components by using a self-template dissolution-regrowth mechanism to give flake-shell silica microcapsules. The capsules shrink under thermal stimulus and their structures can be adjusted by treatment at different pH values. Tuning of shell pore diameters leads to tailored drug release over prolonged periods. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Joint Manipulation: Toward a General Theory of High-Velocity, Low-Amplitude Thrust Techniques.

    PubMed

    Harwich, Andrew S

    2017-12-01

    The objective of this study was to describe the initial stage of a generalized theory of high-velocity, low-amplitude thrust (HVLAT) techniques for joint manipulation. This study examined the movements described by authors from the fields of osteopathy, chiropractic, and physical therapy to produce joint cavitation in both the metacarpophalangeal (MCP) joint and the cervical spine apophysial joint. This study qualitatively compared the kinetics, the similarities, and the differences between MCP cavitation and cervical facet joint cavitation. A qualitative vector analysis of forces and movements was undertaken by constructing computer-generated, simplified graphical models of the MCP joint and a typical cervical apophysial joint and imposing the motions dictated by the clinical technique. Comparing the path to cavitation of 2 modes of HVLAT for the MCP joint, namely, distraction and hyperflexion, it was found that the hyperflexion method requires an axis of rotation, the hinge axis, which is also required for cervical HVLAT. These results show that there is an analogue of cervical HVLAT in one of the MCP joint HVLATs. The study demonstrated that in a theoretical model, the path to joint cavitation is the same for asymmetric separation of the joint surfaces in the cervical spine and the MCP joints.

  14. Moisture diffusion and permeability characteristics of hydroxypropylmethylcellulose and hard gelatin capsules.

    PubMed

    Barham, Ahmad S; Tewes, Frederic; Healy, Anne Marie

    2015-01-30

    The primary objective of this paper is to compare the sorption characteristics of hydroxypropylmethylcellulose (HPMC) and hard gelatin (HG) capsules and their ability to protect capsule contents. Moisture sorption and desorption isotherms for empty HPMC and HG capsules have been investigated using dynamic vapour sorption (DVS) at 25°C. All sorption studies were analysed using the Young-Nelson model equations which distinguishes three moisture sorption types: monolayer adsorption moisture, condensation and absorption. Water vapour diffusion coefficients (D), solubility (S) and permeability (P) parameters of the capsule shells were calculated. ANOVA was performed with the Tukey comparison test to analyse the effect of %RH and capsule type on S, P, and D parameters. The moisture uptake of HG capsules were higher than HPMC capsules at all %RH conditions studied. It was found that values of D and P across HPMC capsules were greater than for HG capsules at 0-40 %RH; whereas over the same %RH range S values were higher for HG than for HPMC capsules. S values decreased gradually as the %RH was increased up to 60% RH. To probe the effect of moisture ingress, spray dried lactose was loaded into capsules. Phase evolution was characterised by scanning electron microscopy (SEM), X-ray powder diffraction (XRD), and differential scanning calorimetry (DSC). The capsules under investigation are not capable of protecting spray dried lactose from induced solid state changes as a result of moisture uptake. For somewhat less moisture sensitive formulations, HPMC would appear to be a better choice than HG in terms of protection of moisture induced deterioration. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Management of acromioclavicular joint injuries.

    PubMed

    Li, Xinning; Ma, Richard; Bedi, Asheesh; Dines, David M; Altchek, David W; Dines, Joshua S

    2014-01-01

    Acromioclavicular joint injuries are among the most common shoulder girdle injuries in athletes and most commonly result from a direct force to the acromion with the arm in an adducted position. Acromioclavicular joint injuries often present with associated injuries to the glenohumeral joint, including an increased incidence of superior labrum anterior posterior (SLAP) tears that may warrant further evaluation and treatment. Anteroposterior stability of the acromioclavicular joint is conferred by the capsule and acromioclavicular ligaments, of which the posterior and superior ligaments are the strongest. Superior-inferior stability is maintained by the coracoclavicular (conoid and trapezoid) ligaments. Type-I or type-II acromioclavicular joint injuries have been treated with sling immobilization, early shoulder motion, and physical therapy, with favorable outcomes. Return to activity can occur when normal shoulder motion and strength are obtained and the shoulder is asymptomatic as compared with the contralateral normal extremity. The management of type-III injuries remains controversial and is individualized. While a return to the previous level of functional activity with nonsurgical treatment has been documented in a number of case series, surgical reduction and coracoclavicular ligament reconstruction has been associated with a favorable outcome and can be considered in patients who place high functional demands on their shoulders or in athletes who participate in overhead sports. Surgical management is indicated for high-grade (≥type IV) acromioclavicular joint injuries to achieve anatomic reduction of the acromioclavicular joint, reconstruction of the coracoclavicular ligaments, and repair of the deltotrapezial fascia. Outcomes after surgical reconstruction of the coracoclavicular ligaments have been satisfactory with regard to achieving pain relief and return to functional activities, but further improvements in the biomechanical strength of these

  16. Improvement in Capsule Abort Performance Using Supersonic Aerodynamic Interaction by Fences

    NASA Astrophysics Data System (ADS)

    Koyama, Hiroto; Wang, Yunpeng; Ozawa, Hiroshi; Doi, Katsunori; Nakamura, Yoshiaki

    The space transportation system will need advanced abort systems to secure crew against serious accidents. Here this study deals with the capsule-type space transportation systems with a Launch Abort System (LAS). This system is composed of a conic capsule as a Launch Abort Vehicle (LAV) and a cylindrical rocket as a Service Module (SM), and the capsule is moved away from the rocket by supersonic aerodynamic interactions in an emergency. We propose a method to improve the performance of the LAV by installing fences at the edges of surfaces on the rocket and capsule sides. Their effects were investigated by experimental measurements and numerical simulations. Experimental results show that the fences on the rocket and capsule surfaces increase the aerodynamic thrust force on the capsule by 70% in a certain clearance between the capsule and rocket. Computational results show the detailed flow fields where the centripetal flow near the surface on the rocket side is induced by the fence on the rocket side and the centrifugal flow near the surface on the capsule side is blocked by the fence on the capsule side. These results can confirm favorable effects of the fences on the performance of the LAS.

  17. Engineering multifunctional capsules through the assembly of metal-phenolic networks.

    PubMed

    Guo, Junling; Ping, Yuan; Ejima, Hirotaka; Alt, Karen; Meissner, Mirko; Richardson, Joseph J; Yan, Yan; Peter, Karlheinz; von Elverfeldt, Dominik; Hagemeyer, Christoph E; Caruso, Frank

    2014-05-26

    Metal-organic coordination materials are of widespread interest because of the coupled benefits of inorganic and organic building blocks. These materials can be assembled into hollow capsules with a range of properties, which include selective permeability, enhanced mechanical/thermal stability, and stimuli-responsiveness. Previous studies have primarily focused on the assembly aspects of metal-coordination capsules; however, the engineering of metal-specific functionality for capsule design has not been explored. A library of functional metal-phenolic network (MPN) capsules prepared from a phenolic ligand (tannic acid) and a range of metals is reported. The properties of the MPN capsules are determined by the coordinated metals, allowing for control over film thickness, disassembly characteristics, and fluorescence behavior. Furthermore, the functional properties of the MPN capsules were tailored for drug delivery, positron emission tomography (PET), magnetic resonance imaging (MRI), and catalysis. The ability to incorporate multiple metals into MPN capsules demonstrates that a diverse range of functional materials can be generated. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Effect of ZnO facet on ethanol steam reforming over Co/ZnO

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yu, Ning; Zhang, He; Davidson, Stephen D.

    2016-01-01

    The effects of ZnO facets on ethanol steam reforming (ESR) were investigated over Co/ZnO catalysts synthesized using ZnO with different fractions of (10-10) non-polar facet. Co supported on ZnO with a higher fraction of (10-10) non-polar facet shows higher C-C cleavage activity and higher selectivity to CO2 (lower selectivity to CO) compared with Co supported on ZnO with less (10-10) non-polar facet exposed. The improved ethanol steam reforming performances are attributed to the high fraction of metallic Co stabilized by the ZnO (10-10) non-polar facet, which enhanced C-C cleavage and water-gas-shift (WGS) activities.

  19. Technical Design Report for the FACET-II Project at SLAC National Accelerator Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None, None

    Electrons can “surf” on waves of plasma – a hot gas of charged particles – gaining very high energies in very short distances. This approach, called plasma wakefield acceleration, has the potential to dramatically shrink the size and cost of particle accelerators. Research at the SLAC National Accelerator Laboratory has demonstrated that plasmas can provide 1,000 times the acceleration in a given distance compared with current technologies. Developing revolutionary and more efficient acceleration techniques that allow for an affordable high-energy collider has been the focus of FACET, a National User Facility at SLAC. FACET used part of SLAC’s two-mile-long linearmore » accelerator to generate high-density beams of electrons and their antimatter counterparts, positrons. Research into plasma wakefield acceleration was the primary motivation for constructing FACET. In April 2016, FACET operations came to an end to make way for the second phase of SLAC’s x-ray laser, the LCLS-II, which will use part of the tunnel occupied by FACET. FACET-II is a new test facility to provide the unique capability to develop advanced acceleration and coherent radiation techniques with high-energy electron and positron beams. FACET-II represents a major upgrade over current FACET capabilities and the breadth of the potential research program makes it truly unique.« less

  20. Bioequivalence of a methylphenidate hydrochloride extended-release preparation: comparison of an intact capsule and an opened capsule sprinkled on applesauce.

    PubMed

    Fischer, R; Schütz, H; Grossmann, M; Leis, H J; Ammer, R

    2006-03-01

    To assess bioequivalence between an intact capsule and the content of a capsule sprinkled on applesauce. Medikinet retard 20 mg capsules were obtained from Medice (Iserlohn, Germany). This was a single-center, completely randomized, open, 2-period, 2-sequence, balanced crossover study with a washout period of 1 week between administrations, in 12 healthy male and female subjects, aged 18-45 years. Blood samples were collected over 24 hours and methylphenidate plasma concentration-time data were used to calculate pharmacokinetic parameters for both administrations. The main parameters were (confirmatory) AUC0-tz (extent of BA), Cmax, tmax (rate of BA) and (descriptively) AUC0-infinity and t1/2. Equivalence was concluded if the 90% confidence interval (CI) for the ratio between test and reference was 0.80-1.25 (AUC0-tz). All 12 dosed subjects finished both treatment periods and were included in pharmacokinetic and safety analyses. 90% geometric confidence intervals for AUC0-tz and Cmax data were well within accepted bioequivalence limits. The study has shown that both treatment modes lead to similar pattern of absorption and elimination following single-dose administration in the fed state. The test treatment (content of capsule sprinkled over 15 ml applesauce) is bioequivalent to the reference treatment (intact capsule) in terms of extent and rate of absorption. Data collected from this study demonstrate that Medikinet retard capsules can be opened and the content sprinkled on a tablespoon of applesauce without influencing the rate and extent of bioavailability.

  1. Impulsivity facets' predictive relations with DSM-5 PTSD symptom clusters.

    PubMed

    Roley, Michelle E; Contractor, Ateka A; Weiss, Nicole H; Armour, Cherie; Elhai, Jon D

    2017-01-01

    Posttraumatic stress disorder (PTSD) has a well-established theoretical and empirical relation with impulsivity. Prior research has not used a multidimensional approach for measuring both PTSD and impulsivity constructs when assessing their relationship. The current study assessed the unique relationship of impulsivity facets on PTSD symptom clusters among a nonclinical sample of 412 trauma-exposed adults. Linear regression analyses revealed that impulsivity facets best accounted for PTSD's arousal symptoms. The negative urgency facet of impulsivity was most predictive, because it was associated with all of PTSD's symptom clusters. Sensation seeking did not predict PTSD's intrusion symptoms, but did predict the other symptom clusters of PTSD. Lack of perseverance only predicted intrusion symptoms, while lack of premeditation only predicted PTSD's mood/cognition symptoms. Results extend theoretical and empirical research on the impulsivity-PTSD relationship, suggesting that impulsivity facets may serve as both risk and protective factors for PTSD symptoms. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  2. [Clinical Efficacy of Supplementary Treatment of Gukang Capsules to the Elder Patients with Fracture of Distal Radius].

    PubMed

    Wang, Wei; Liao, Su-ping; Wei, Lei

    2015-01-01

    To study the clinical efficacy of supplementary treatment of tukang Capsules to the elder patients with fracture of the distal radius. A total of 108 elder patients with fracture of the distal radius diagnosed by X-ray,who visited orthopedics department of Pu' ai Hospital in January 2012 - December 2013, were randomly divided into observation group and control group. Cases in both groups received the operation of internal fixation by T-type plate. Cases in control group received oral Calcium Carbonate Tablets, and cases in observation group received Gukang Capsules besides Calcium Carbonate Tablets. Treatment duration was four weeks. The painful and swelling degree of wrist joints, levels of type I propeptide carboxy-terminal procollagen (P I CP) and bone glaprotein(BGP) in serum were compared. Hospitalization and fracture healing time, as well as recovery condition of wrist joints in the sixth month after operation were compared. The VAS of both groups was not significantly different before operation and in the 28th day after operation(P >0. 05), but the VAS in observation group was significantly lower than that in control group in the 3rd,5th, 7th, 14th and 21th day after operation(P <0. 01). The swelling scale of both groups was not significantly different before operation and in the 28th day after operation(P >0. 05), but the swelling scale in observation group was significantly lower than that in control group in the 3rd, 5th, 7th, 14th and 21th day after operation(P <0. 01). The levels of P I CP and BGP in serum of both groups were not significantly different before operation(P >0. 05), but the levels of P I CP and BGP in serum of observation groups were significantly higher than that in control group one and two months after operation (P <0. 01). Hospitalization and fracture healing time in observation group was significantly shortened compared with control group (P <0. 05). The effective ratio in observation group was 79. 63%, significantly higher than that

  3. Fluorescence enhancement and strong-coupling in faceted plasmonic nanocavities

    NASA Astrophysics Data System (ADS)

    Kongsuwan, Nuttawut; Demetriadou, Angela; Chikkaraddy, Rohit; Baumberg, Jeremy J.; Hess, Ortwin

    2018-06-01

    Emission properties of a quantum emitter can be significantly modified inside nanometre-sized gaps between two plasmonic nanostructures. This forms a nanoscopic optical cavity which allows single-molecule detection and single-molecule strong-coupling at room temperature. However, plasmonic resonances of a plasmonic nanocavity are highly sensitive to the exact gap morphology. In this article, we shed light on the effect of gap morphology on the plasmonic resonances of a faceted nanoparticle-on-mirror (NPoM) nanocavity and their interaction with quantum emitters. We find that with increasing facet width the NPoM nanocavity provides weaker field enhancement and thus less coupling strength to a single quantum emitter since the effective mode volume increases with the facet width. However, if multiple emitters are present, a faceted NPoM nanocavity is capable of accommodating a larger number of emitters, and hence the overall coupling strength is larger due to the collective and coherent energy exchange from all the emitters. Our findings pave the way to more efficient designs of nanocavities for room-temperature light-matter strong-coupling, thus providing a big step forward to a non-cryogenic platform for quantum technologies.

  4. Spectral measurements of asymmetrically irradiated capsule backlighters

    DOE PAGES

    Keiter, P. A.; Drake, R. P.

    2016-09-09

    Capsule backlighters provide a quasi-continuum x-ray spectrum over a wide range of photon energies. Ideally one irradiates the capsule backlighter symmetrically, however, in complex experimental geometries, this is not always possible. In recent experiments we irradiated capsule backlighters asymmetrically and measured the x-ray spectrum from multiple directions. We will present time-integrated spectra over the photon energy range of ~2-13 keV and time-resolved spectra over the photon energy range of ~2-3 keV. Lastly, we will compare the spectra from different lines of sight to determine if the laser asymmetry results in an angular dependence in the x-ray emission.

  5. Distinct water activation on polar/non-polar facets of ZnO nanoparticles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, He; Sun, Junming; Liu, Changjun

    2015-11-01

    ZnO nanoparticles with differing dominant facets were prepared and characterized by a complimentary of techniques such as X-ray diffraction, electron microscopy, temperature programmed desorption of H2O, and Fourier transform infrared spectroscopy analysis of adsorbed D2O. For the first time, water interaction/activation is compared on ZnO polar and non-polar facets. We report that non-polar facets exhibit high activity in water activation, which favors reactions such as ketonization and steam reforming in which dissociated water is involved. The distinct water dissociation on ZnO non-polar facets could be related to its facile formation of oxygen vacancies under realistic reaction conditions.

  6. State diagram for adhesion dynamics of deformable capsules under shear flow.

    PubMed

    Luo, Zheng Yuan; Bai, Bo Feng

    2016-08-17

    Due to the significance of understanding the underlying mechanisms of cell adhesion in biological processes and cell capture in biomedical applications, we numerically investigate the adhesion dynamics of deformable capsules under shear flow by using a three-dimensional computational fluid dynamic model. This model is based on the coupling of the front tracking-finite element method for elastic mechanics of the capsule membrane and the adhesion kinetics simulation for adhesive interactions between capsules and functionalized surfaces. Using this model, three distinct adhesion dynamic states are predicted, such as detachment, rolling and firm-adhesion. Specifically, the effects of capsule deformability quantified by the capillary number on the transitions of these three dynamic states are investigated by developing an adhesion dynamic state diagram for the first time. At low capillary numbers (e.g. Ca < 0.0075), whole-capsule deformation confers the capsule a flattened bottom in contact with the functionalized surface, which hence promotes the rolling-to-firm-adhesion transition. It is consistent with the observations from previous studies that cell deformation promotes the adhesion of cells lying in the rolling regime. However, it is surprising to find that, at relatively high capillary numbers (e.g. 0.0075 < Ca < 0.0175), the effect of capsule deformability on its adhesion dynamics is far more complex than just promoting adhesion. High deformability of capsules makes their bottom take a concave shape with no adhesion bond formation in the middle. The appearance of this specific capsule shape inhibits the transitions of both rolling-to-firm-adhesion and detachment-to-rolling, and it means that capsule deformation no longer promotes the capsule adhesion. Besides, it is interesting to note that, when the capillary number exceeds a critical value (e.g. Ca = 0.0175), the rolling state no longer appears, since capsules exhibit large deviation from the spherical shape.

  7. Magnetized HDC ignition capsules for yield enhancement and implosion magnetohydrodynamics

    NASA Astrophysics Data System (ADS)

    Zimmerman, G.; Ho, D.; Perkins, J.; Logan, G.; Hawkins, S.; Rhodes, M.

    2014-10-01

    Imposing a magnetic field on capsules can turn capsules that fail, because of low 1-D margin, into igniting capsules that give yield in the MegaJoule range. The imposed magnetic field can be amplified by up to O(103) as it is being compressed by the imploding shell, e.g. if the initial field is 50 T, then the field in the hot spot of the assembled configuration can reach >104 T. (We are currently designing hardware that can provide a field in the 50 T range inside NIF hohlraums.) With this highly compressed field strength, the gyro radius of alpha particles becomes smaller than the hot spot size. Consequently, the heating of the hot spot becomes more efficient. The imposed field can also prevent hot electrons in the holhraum from reaching the capsule. We choose capsules with high-density carbon (HDC) ablators for this study. HDC capsules have good 1-D performance and also have short pulses (10 ns or less), allowing the use of low gas-filled or near-vacuum hohlraums which provide high coupling efficiency. We describe a 2-D simulation of a 3-shock HDC capsule. We will show detailed magnetohydrodynamic evolution of the implosion. HDC capsules with 2-shock pulses have low margin because of their high adiabat, and it is difficult to achieve ignition in realistic 2-D simulations. The improvement in performance for 2-shock magnetized capsules will be presented. This work was supported by LLNL Laboratory Directed Research and Development LDRD 14-ER-028 under Contract DE-AC52-07NA27344.

  8. Genome wide gene expression analysis of the posterior capsule in patients with osteoarthritis and knee flexion contracture.

    PubMed

    Campbell, Thomas Mark; Trudel, Guy; Wong, Kayleigh Kristin; Laneuville, Odette

    2014-11-01

    Knee flexion contractures (KFC) are limitations in the ability to fully extend the knee joint. In people with knee osteoarthritis (OA), KFC are common, impair function, and worsen outcomes after arthroplasty. In KFC, the posterior knee capsule is believed to play a key role, but the pathophysiology remains poorly understood. We sought to identify gene expression differences in the posterior knee capsule of patients with OA with and without KFC. Capsule tissue was obtained from the knees of 12 subjects diagnosed with advanced-stage OA at the time of knee arthroplasty surgery. The presence or absence of KFC allocated patients into 2 groups using a case-control design. Genomewide capsular gene expression was compared between the 2 patient groups. Confirmation of differential expression of the corresponding proteins was performed by immunohistochemistry on tissue sections. There were no significant demographic differences between the patients with OA with KFC and without KFC save for reduced extension in their surgical knee (p<0.01). KFC patients showed a 6.4-fold decrease in CSN1S1 (p=0.017) gene expression and a 3.7-, 2.0-, and 2.6-fold increase in CHAD, Sox9, and Cyr61 gene expression, respectively (p=0.001, 0.004, 0.001, respectively). There were corresponding increases in protein levels for chondroadherin, sex determining region Y-box 9, and casein alphaS1 (all p<0.05). Functional analysis of the differentially expressed genes indicated a strong association with pathways related to the extracellular matrix and to tissue fibrosis. Posterior capsules in endstage OA knees with KFC exhibited differential expression of 4 genes all previously documented to be associated with tissue fibrosis.

  9. Local facet approximation for image stitching

    NASA Astrophysics Data System (ADS)

    Li, Jing; Lai, Shiming; Liu, Yu; Wang, Zhengming; Zhang, Maojun

    2018-01-01

    Image stitching aims at eliminating multiview parallax and generating a seamless panorama given a set of input images. This paper proposes a local adaptive stitching method, which could achieve both accurate and robust image alignments across the whole panorama. A transformation estimation model is introduced by approximating the scene as a combination of neighboring facets. Then, the local adaptive stitching field is constructed using a series of linear systems of the facet parameters, which enables the parallax handling in three-dimensional space. We also provide a concise but effective global projectivity preserving technique that smoothly varies the transformations from local adaptive to global planar. The proposed model is capable of stitching both normal images and fisheye images. The efficiency of our method is quantitatively demonstrated in the comparative experiments on several challenging cases.

  10. Identification of the duodenal papilla by colon capsule endoscope.

    PubMed

    Karagiannis, S; Dücker, C; Dautel, P; Strubenhoff, J; Faiss, S

    2010-07-01

    The sensitivity of small-bowel capsule endoscopy in visualizing a single finding present in everyone, the duodenal papilla, is limited. In this retrospective case series study we evaluated whether the duodenal papilla can be better visualized by a capsule endoscope equipped with cameras on both ends. The recordings of 45 colonic capsule endoscopies (PillCam Colon) performed in a single tertiary center were re-evaluated seeking for the duodenal papilla. The two-hour sleeping period of the colon capsule endoscopy system led to the imaging of duodenum in 10 / 45 patients. The duodenal papilla was identified in 6 / 10 (60 %) patients while the number of frames where the papilla was clearly visualized ranged from 2 - 9. Consequently, a small-bowel capsule endoscope containing two cameras could better identify the duodenal papilla and theoretically other obscure areas of the small bowel, expanding its diagnostic accuracy.

  11. Smooth and vertical facet formation for AlGaN-based deep-UV laser diodes.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bogart, Katherine Huderle Andersen; Shul, Randy John; Stevens, Jeffrey

    2008-10-01

    Using a two-step method of plasma and wet chemical etching, we demonstrate smooth, vertical facets for use in Al{sub x} Ga{sub 1-x} N-based deep-ultraviolet laser-diode heterostructures where x = 0 to 0.5. Optimization of plasma-etching conditions included increasing both temperature and radiofrequency (RF) power to achieve a facet angle of 5 deg from vertical. Subsequent etching in AZ400K developer was investigated to reduce the facet surface roughness and improve facet verticality. The resulting combined processes produced improved facet sidewalls with an average angle of 0.7 deg from vertical and less than 2-nm root-mean-square (RMS) roughness, yielding an estimated reflectivity greatermore » than 95% of that of a perfectly smooth and vertical facet.« less

  12. Laundry detergent capsules and pediatric poisoning.

    PubMed

    Bonney, Asha G; Mazor, Suzan; Goldman, Ran D

    2013-12-01

    A 4-year-old girl was brought into the emergency department vomiting after having had ingested a laundry detergent capsule (LDC) from under the sink at her house. What is the risk of LDC poisoning? What can be done to treat these children? Laundry detergent capsules are relatively new to supermarket shelves in North America, and there has been an emergence of case reports in the literature describing LDC poisoning, which is worse than poisoning from other laundry detergents. Very little is known about the mechanisms causing these severe reactions, which include airway compromise and esophageal perforation, but the attractive appearance of these capsules and easy access at home has governments and health officials concerned about an increase in poisoning. No residual problems have been associated with these cases to date; however, further research is needed to assess long-term effects.

  13. Lens capsule structure assessed with atomic force microscopy

    PubMed Central

    Sueiras, Vivian M.; Moy, Vincent T.

    2015-01-01

    Purpose To image the ultrastructure of the anterior lens capsule at the nanoscale level using atomic force microscopy (AFM). Methods Experiments were performed on anterior lens capsules maintained in their in situ location surrounding the lens from six human cadavers (donor age range: 44–88 years), four cynomolgus monkeys (Macaca fascicularis age range: 4.83–8.92 years), and seven pigs (<6 months). Hydration of all samples was maintained using Dulbecco’s Modified Eagle Medium (DMEM). Whole lenses were removed from the eye and placed anterior side up in agarose gel before gel hardening where only the posterior half of the lens was contained within the gel. After the gel hardened, the Petri dish was filled with DMEM until the point where the intact lens was fully submerged. AFM was used to image the anterior lens surface in contact mode. An integrated analysis program was used to calculate the interfibrillar spacing, fiber diameter, and surface roughness of the samples. Results The AFM images depict a highly ordered fibrous structure at the surface of the lens capsule in all three species. The interfibrillar spacing for the porcine, cynomolgus monkey, and human lens capsules was 0.68±0.25, 1.80±0.39, and 1.08±0.25 μm, respectively. In the primate, interfibrillar spacing significantly decreased linearly as a function of age. The fiber diameters ranged from 50 to 950 nm. Comparison of the root mean square (RMS) and average deviation demonstrate that the surface of the porcine lens capsule is the smoothest, and that the human and cynomolgus monkey capsules are significantly rougher. Conclusions AFM was successful in providing high-resolution images of the nanostructure of the lens capsule samples. Species-dependent differences were observed in the overall structure and surface roughness. PMID:25814829

  14. Capsule endoscopy in the diagnosis of Crohn's disease.

    PubMed

    Niv, Yaron

    2013-01-01

    Crohn's disease is a chronic inflammatory disorder affecting any part of the gastrointestinal tract, but frequently involves the small and large bowel. Typical presenting symptoms include abdominal pain and diarrhea. Patients with this disorder may also have extraintestinal manifestations, including arthritis, uveitis, and skin lesions. The PillCam™SB capsule is an ingestible disposable video camera that transmits high quality images of the small intestinal mucosa. This enables the small intestine to be readily accessible to physicians investigating for the presence of small bowel disorders, such as Crohn's disease. Four meta-analyses have demonstrated that capsule endoscopy identifies Crohn's disease when other methods are not helpful. It should be noted that it is the best noninvasive procedure for assessing mucosal status, but is not superior to ileocolonoscopy, which remains the gold standard for assessment of ileocolonic disease. Mucosal healing along the small bowel can only be demonstrated by an endoscopic procedure such as capsule endoscopy. Achievement of long-term mucosal healing has been associated with a trend towards a decreased need for hospitalization and a decreased requirement for corticosteroid treatment in patients with Crohn's disease. Recently, we have developed and validated the Capsule Endoscopy Crohn's Disease Activity Index (also known as the Niv score) for Crohn's disease of the small bowel. The next step is to expand our score to the colon, and to determine the role and benefit of a capsule endoscopy activity score in patients suffering from Crohn's ileocolitis and/or colitis. This scoring system will also serve to improve our understanding of the impact of capsule endoscopy, and therefore treatment, on the immediate outcome of this disorder. As the best procedure available for assessing mucosal status, capsule endoscopy will provide important information about the course and outcome of Crohn's disease.

  15. Role of capsule endoscopy in inflammatory bowel disease.

    PubMed

    Kopylov, Uri; Seidman, Ernest G

    2014-02-07

    Videocapsule endoscopy (VCE) has revolutionized our ability to visualize the small bowel mucosa. This modality is a valuable tool for the diagnosis of obscure small bowel Crohn's disease (CD), and can also be used for monitoring of disease activity in patients with established small-bowel CD, detection of complications such as obscure bleeding and neoplasms, evaluation of response to anti-inflammatory treatment and postoperative recurrence following small bowel resection. VCE could also be an important tool in the management of patients with unclassified inflammatory bowel disease, potentially resulting in reclassification of these patients as having CD. Reports on postoperative monitoring and evaluation of patients with ileal pouch-anal anastomosis who have developed pouchitis have recenty been published. Monitoring of colonic inflammatory activity in patients with ulcerative colitis using the recently developed colonic capsule has also been reported. Capsule endoscopy is associated with an excellent safety profile. Although retention risk is increased in patients with small bowel CD, this risk can be significanty decreased by a routine utilization of a dissolvable patency capsule preceding the ingestion of the diagnostic capsule. This paper contains an overview of the current and future clinical applications of capsule endoscopy in inflammatory bowel disease.

  16. Ultrasound capsule endoscopy: sounding out the future

    PubMed Central

    Stewart, Fraser; Lay, Holly; Cummins, Gerard; Newton, Ian P.; Desmulliez, Marc P. Y.; Steele, Robert J. C.; Näthke, Inke; Cochran, Sandy

    2017-01-01

    Video capsule endoscopy (VCE) has been of immense benefit in the diagnosis and management of gastrointestinal (GI) disorders since its introduction in 2001. However, it suffers from a number of well recognized deficiencies. Amongst these is the limited capability of white light imaging, which is restricted to analysis of the mucosal surface. Current capsule endoscopes are dependent on visual manifestation of disease and limited in regards to transmural imaging and detection of deeper pathology. Ultrasound capsule endoscopy (USCE) has the potential to overcome surface only imaging and provide transmural scans of the GI tract. The integration of high frequency microultrasound (µUS) into capsule endoscopy would allow high resolution transmural images and provide a means of both qualitative and quantitative assessment of the bowel wall. Quantitative ultrasound (QUS) can provide data in an objective and measurable manner, potentially reducing lengthy interpretation times by incorporation into an automated diagnostic process. The research described here is focused on the development of USCE and other complementary diagnostic and therapeutic modalities. Presently investigations have entered a preclinical phase with laboratory investigations running concurrently. PMID:28567381

  17. Unsteady Pressures on a Generic Capsule Shape

    NASA Technical Reports Server (NTRS)

    Burnside, Nathan; Ross, James C.

    2015-01-01

    While developing the aerodynamic database for the Orion spacecraft, the low-speed flight regime (transonic and below) proved to be the most difficult to predict and measure accurately. The flow over the capsule heat shield in descent flight was particularly troublesome for both computational and experimental efforts due to its unsteady nature and uncertainty about the boundary layer state. The data described here were acquired as part of a study to improve the understanding of the overall flow around a generic capsule. The unsteady pressure measurements acquired on a generic capsule shape are presented along with a discussion about the effects of various flight conditions and heat-shield surface roughness on the resulting pressure fluctuations.

  18. A locomotion mechanism with external magnetic guidance for active capsule endoscope.

    PubMed

    Wang, Xiaona; Meng, Max Q H; Chen, Xijun

    2010-01-01

    Gastrointestinal (GI) disorder is one of the most common diseases in human body. The swallowable wireless capsule endoscopy has been proved to be a convenient, painless and effective way to examine the whole GI tract. However, lack of motion control makes the movement of the capsule substantially random, resulting in missing diagnosis. In this paper, a locomotion mechanism is developed for the next-generation active capsule endoscope. An internal actuator integrated on-board the capsule is designed to provide driving force and improve the dexterity. A small permanent magnet enclosed inside the capsule interacts with an external magnetic field to control the capsule's orientation and offer extra driving force. This mechanism avoids sophisticated and bulky control system and reduces power consumption inside the capsule. Ex-vivo experimental results showed that it can make a controllable movement inside the porcine large intestine. The mechanism also has the potential to be a platform for further development, such as devices of operations, spraying medicine, biopsy etc.

  19. Facet-Controlled Synthetic Strategy of Cu2O-Based Crystals for Catalysis and Sensing.

    PubMed

    Shang, Yang; Guo, Lin

    2015-10-01

    Shape-dependent catalysis and sensing behaviours are primarily focused on nanocrystals enclosed by low-index facets, especially the three basic facets ({100}, {111}, and {110}). Several novel strategies have recently exploded by tailoring the original nanocrystals to greatly improve the catalysis and sensing performances. In this Review, we firstly introduce the synthesis of a variety of Cu 2 O nanocrystals, including the three basic Cu 2 O nanocrystals (cubes, octahedra and rhombic dodecahedra, enclosed by the {100}, {111}, and {110} facets, respectively), and Cu 2 O nanocrystals enclosed by high-index planes. We then discuss in detail the three main facet-controlled synthetic strategies (deposition, etching and templating) to fabricate Cu 2 O-based nanocrystals with heterogeneous, etched, or hollow structures, including a number of important concepts involved in those facet-controlled routes, such as the selective adsorption of capping agents for protecting special facets, and the impacts of surface energy and active sites on reaction activity trends. Finally, we highlight the facet-dependent properties of the Cu 2 O and Cu 2 O-based nanocrystals for applications in photocatalysis, gas catalysis, organocatalysis and sensing, as well as the relationship between their structures and properties. We also summarize and comment upon future facet-related directions.

  20. Capsule-Fixated Intraocular Lens Implantation in Small Pupil Cases.

    PubMed

    Schojai, Merita; Schultz, Tim; Burkhard Dick, H

    2017-08-01

    To describe a new technique for implantation of capsule-fixated intraocular lenses (IOLs) (FEMTIS; Oculentis, Berlin, Germany) in patients with small pupils. In 4 eyes with small pupils, an anterior capsule-fixated IOL was implanted into the capsular bag after femtosecond laser treatment. The two large and two small flaps of the IOL were elevated to the front of the iris and the anterior capsule. Finally, the iris was flipped over the flaps to ensure a fixation of the capsule inside of the capsulotomy. In all cases, the implantation of anterior capsule-fixated IOLs was possible. No complications occurred during surgery or within the first months after surgery. With the described technique, capsulefixated IOLs can be implanted in eyes with small pupil easily and safely. This type of IOL has great potential to improve the refractive outcome by better prediction of the postoperative IOL position and eliminating IOL rotation after cataract surgery. [J Refract Surg. 2017;33(8):568-570.]. Copyright 2017, SLACK Incorporated.

  1. Investigation of albumin-derived perfluorocarbon-based capsules by holographic optical trapping

    PubMed Central

    Köhler, Jannis; Ruschke, Jegor; Ferenz, Katja Bettina; Esen, Cemal; Kirsch, Michael; Ostendorf, Andreas

    2018-01-01

    Albumin-derived perfluorocarbon-based capsules are promising as artificial oxygen carriers with high solubility. However, these capsules have to be studied further to allow initial human clinical tests. The aim of this paper is to provide and characterize a holographic optical tweezer to enable contactless trapping and moving of individual capsules in an environment that mimics physiological (in vivo) conditions most effectively in order to learn more about the artificial oxygen carrier behavior in blood plasma without recourse to animal experiments. Therefore, the motion behavior of capsules in a ring shaped or vortex beam is analyzed and optimized on account of determination of the optical forces in radial and axial direction. In addition, due to the customization and generation of dynamic phase holograms, the optical tweezer is used for first investigations on the aggregation behavior of the capsules and a statistical evaluation of the bonding in dependency of different capsule sizes is performed. The results show that the optical tweezer is sufficient for studying individual perfluorocarbon-based capsules and provide information about the interaction of these capsules for future use as artificial oxygen carriers. PMID:29552409

  2. Optical fiber end-facet polymer suspended-mirror devices

    NASA Astrophysics Data System (ADS)

    Yao, Mian; Wu, Jushuai; Zhang, A. Ping; Tam, Hwa-Yaw; Wai, P. K. A.

    2017-04-01

    This paper presents a novel optical fiber device based on a polymer suspended mirror on the end facet of an optical fiber. With an own-developed optical 3D micro-printing technology, SU-8 suspended-mirror devices (SMDs) were successfully fabricated on the top of a standard single-mode optical fiber. Optical reflection spectra of the fabricated SU- 8 SMDs were measured and compared with theoretical analysis. The proposed technology paves a way towards 3D microengineering of the small end-facet of optical fibers to develop novel fiber-optic sensors.

  3. Nonlinear Wavelength Selection in Surface Faceting under Electromigration

    NASA Astrophysics Data System (ADS)

    Barakat, Fatima; Martens, Kirsten; Pierre-Louis, Olivier

    2012-08-01

    We report on the control of the faceting of crystal surfaces by means of surface electromigration. When electromigration reinforces the faceting instability, we find perpetual coarsening with a wavelength increasing as t1/2. For strongly stabilizing electromigration, the surface is stable. For weakly stabilizing electromigration, a cellular pattern is obtained, with a nonlinearly selected wavelength. The selection mechanism is not caused by an instability of steady states, as suggested by previous works in the literature. Instead, the dynamics is found to exhibit coarsening before reaching a continuous family of stable nonequilibrium steady states.

  4. Buckling behavior of origami unit cell facets under compressive loads

    NASA Astrophysics Data System (ADS)

    Kshad, Mohamed Ali Emhmed; Naguib, Hani E.

    2018-03-01

    Origami structures as cores for sandwich structures are designed to withstand the compressive loads and to dissipate compressive energy. The deformation of the origami panels and the unit cell facets are the primary factors behind the compressive energy dissipation in origami structures. During the loading stage, the origami structures deform through the folding and unfolding process of the unit cell facets, and also through the plastic deformation of the facets. This work presents a numerical study of the buckling behavior of different origami unit cell elements under compressive loading. The studied origami configurations were Miura and Ron-Resch-like origami structures. Finite element package was used to model the origami structures. The study investigated the buckling behavior of the unit cell facets of two types of origami structures Miura origami and Ron-Resch-Like origami structures. The simulation was conducted using ANSYS finite element software, in which the model of the unit cell represented by shell elements, and the eigenvalues buckling solver was used to predict the theoretical buckling of the unit cell elements.

  5. Double-balloon endoscopy as the primary method for small-bowel video capsule endoscope retrieval.

    PubMed

    Van Weyenberg, Stijn J B; Van Turenhout, Sietze T; Bouma, Gerd; Van Waesberghe, Jan Hein T M; Van der Peet, Donald L; Mulder, Chris J J; Jacobs, Maarten A J M

    2010-03-01

    Capsule retention in the small bowel is a known complication of small-bowel video capsule endoscopy. Surgery is the most frequently used method of capsule retrieval. To determine the incidence and causes of capsule retention and to describe double-balloon endoscopy (DBE) as the primary technique used for capsule retrieval. Retrospective analysis of all video capsule studies was performed at our center, and evaluation of the outcome of DBE was the first method used to retrieve entrapped video capsules. Tertiary referral center. A total of 904 patients who underwent small-bowel video capsule endoscopy. Capsule retrieval by DBE. The number of patients in whom capsule retention occurred and the number of patients in whom an entrapped capsule could be retrieved by using DBE. Capsule retention occurred in 8 patients (incidence 0.88%; 95% CI, 0.41%-1.80%) and caused acute small-bowel obstruction in 6 patients. All retained capsules were successfully removed during DBE. Five patients underwent elective surgery to treat the underlying cause of capsule retention. One patient required emergency surgery because of multiple small-bowel perforations. Retrospective design. In our series, the incidence of capsule retention was low. DBE is a reliable method for removing retained capsules and might prevent unnecessary surgery. If surgery is required, preoperative capsule retrieval allows preoperative diagnosis, adequate staging in case of malignancy, and optimal surgical planning. 2010 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  6. Design of illumination system in ring field capsule endoscope

    NASA Astrophysics Data System (ADS)

    Jeng, Wei-De; Mang, Ou-Yang; Chen, Yu-Ta; Wu, Ying-Yi

    2011-03-01

    This paper is researching about the illumination system in ring field capsule endoscope. It is difficult to obtain the uniform illumination on the observed object because the light intensity of LED will be changed along its angular displacement and same as luminous intensity distribution curve. So we use the optical design software which is Advanced Systems Analysis Program (ASAP) to build a photometric model for the optimal design of LED illumination system in ring field capsule endoscope. In this paper, the optimal design of illumination uniformity in the ring field capsule endoscope is from origin 0.128 up to optimum 0.603 and it would advance the image quality of ring field capsule endoscope greatly.

  7. Plasma wakefield acceleration experiments at FACET II

    NASA Astrophysics Data System (ADS)

    Joshi, C.; Adli, E.; An, W.; Clayton, C. E.; Corde, S.; Gessner, S.; Hogan, M. J.; Litos, M.; Lu, W.; Marsh, K. A.; Mori, W. B.; Vafaei-Najafabadi, N.; O'shea, B.; Xu, Xinlu; White, G.; Yakimenko, V.

    2018-03-01

    During the past two decades of research, the ultra-relativistic beam-driven plasma wakefield accelerator (PWFA) concept has achieved many significant milestones. These include the demonstration of ultra-high gradient acceleration of electrons over meter-scale plasma accelerator structures, efficient acceleration of a narrow energy spread electron bunch at high-gradients, positron acceleration using wakes in uniform plasmas and in hollow plasma channels, and demonstrating that highly nonlinear wakes in the ‘blow-out regime’ have the electric field structure necessary for preserving the emittance of the accelerating bunch. A new 10 GeV electron beam facility, Facilities for Accelerator Science and Experimental Test (FACET) II, is currently under construction at SLAC National Accelerator Laboratory for the next generation of PWFA research and development. The FACET II beams will enable the simultaneous demonstration of substantial energy gain of a small emittance electron bunch while demonstrating an efficient transfer of energy from the drive to the trailing bunch. In this paper we first describe the capabilities of the FACET II facility. We then describe a series of PWFA experiments supported by numerical and particle-in-cell simulations designed to demonstrate plasma wake generation where the drive beam is nearly depleted of its energy, high efficiency acceleration of the trailing bunch while doubling its energy and ultimately, quantifying the emittance growth in a single stage of a PWFA that has optimally designed matching sections. We then briefly discuss other FACET II plasma-based experiments including in situ positron generation and acceleration, and several schemes that are promising for generating sub-micron emittance bunches that will ultimately be needed for both an early application of a PWFA and for a plasma-based future linear collider.

  8. Plasma wakefield acceleration experiments at FACET II

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Joshi, C.; Adli, E.; An, W.

    During the past two decades of research, the ultra-relativistic beam-driven plasma wakefield accelerator (PWFA) concept has achieved many significant milestones. These include the demonstration of ultra-high gradient acceleration of electrons over meter-scale plasma accelerator structures, efficient acceleration of a narrow energy spread electron bunch at high-gradients, positron acceleration using wakes in uniform plasmas and in hollow plasma channels, and demonstrating that highly nonlinear wakes in the 'blow-out regime' have the electric field structure necessary for preserving the emittance of the accelerating bunch. A new 10 GeV electron beam facility, Facilities for Accelerator Science and Experimental Test (FACET) II, is currentlymore » under construction at SLAC National Accelerator Laboratory for the next generation of PWFA research and development. The FACET II beams will enable the simultaneous demonstration of substantial energy gain of a small emittance electron bunch while demonstrating an efficient transfer of energy from the drive to the trailing bunch. In this paper we first describe the capabilities of the FACET II facility. We then describe a series of PWFA experiments supported by numerical and particle-in-cell simulations designed to demonstrate plasma wake generation where the drive beam is nearly depleted of its energy, high efficiency acceleration of the trailing bunch while doubling its energy and ultimately, quantifying the emittance growth in a single stage of a PWFA that has optimally designed matching sections. Here, we briefly discuss other FACET II plasma-based experiments including in situ positron generation and acceleration, and several schemes that are promising for generating sub-micron emittance bunches that will ultimately be needed for both an early application of a PWFA and for a plasma-based future linear collider.« less

  9. Plasma wakefield acceleration experiments at FACET II

    DOE PAGES

    Joshi, C.; Adli, E.; An, W.; ...

    2018-01-12

    During the past two decades of research, the ultra-relativistic beam-driven plasma wakefield accelerator (PWFA) concept has achieved many significant milestones. These include the demonstration of ultra-high gradient acceleration of electrons over meter-scale plasma accelerator structures, efficient acceleration of a narrow energy spread electron bunch at high-gradients, positron acceleration using wakes in uniform plasmas and in hollow plasma channels, and demonstrating that highly nonlinear wakes in the 'blow-out regime' have the electric field structure necessary for preserving the emittance of the accelerating bunch. A new 10 GeV electron beam facility, Facilities for Accelerator Science and Experimental Test (FACET) II, is currentlymore » under construction at SLAC National Accelerator Laboratory for the next generation of PWFA research and development. The FACET II beams will enable the simultaneous demonstration of substantial energy gain of a small emittance electron bunch while demonstrating an efficient transfer of energy from the drive to the trailing bunch. In this paper we first describe the capabilities of the FACET II facility. We then describe a series of PWFA experiments supported by numerical and particle-in-cell simulations designed to demonstrate plasma wake generation where the drive beam is nearly depleted of its energy, high efficiency acceleration of the trailing bunch while doubling its energy and ultimately, quantifying the emittance growth in a single stage of a PWFA that has optimally designed matching sections. Here, we briefly discuss other FACET II plasma-based experiments including in situ positron generation and acceleration, and several schemes that are promising for generating sub-micron emittance bunches that will ultimately be needed for both an early application of a PWFA and for a plasma-based future linear collider.« less

  10. Laundry detergent capsules and pediatric poisoning

    PubMed Central

    Bonney, Asha G.; Mazor, Suzan; Goldman, Ran D.

    2013-01-01

    Abstract Question A 4-year-old girl was brought into the emergency department vomiting after having had ingested a laundry detergent capsule (LDC) from under the sink at her house. What is the risk of LDC poisoning? What can be done to treat these children? Answer Laundry detergent capsules are relatively new to supermarket shelves in North America, and there has been an emergence of case reports in the literature describing LDC poisoning, which is worse than poisoning from other laundry detergents. Very little is known about the mechanisms causing these severe reactions, which include airway compromise and esophageal perforation, but the attractive appearance of these capsules and easy access at home has governments and health officials concerned about an increase in poisoning. No residual problems have been associated with these cases to date; however, further research is needed to assess long-term effects. PMID:24336541

  11. Regulating Surface Facets of Metallic Aerogel Electrocatalysts by Size-dependent Localized Ostwald Ripening.

    PubMed

    Wenchao, Duan; Zhang, Peina; Xiahou, Yujiao; Song, Yahui; Bi, Cuixia; Zhan, Jie; Du, Wei; Huang, Lihui; Möhwald, Helmuth; Xia, Haibing

    2018-06-21

    It is well known that the activity and stability of electrocatalysts are largely dependent on their surface facets. In this work, we have successfully regulated surface facets of three-dimensional (3D) metallic Au m-n aerogels by salt-induced assembly of citrate-stabilized gold nanoparticles (Au NPs) of two different sizes and further size-dependent localized Ostwald ripening at controlled particle-number ratios, where m and n represent the size of Au NPs, respectively. In addition, 3D Au m-n @Pd aerogels were further synthesized on the basis of Au m-n aerogels and also bear controlled surface facets due to the formation of ultrathin Pd layers on Au m-n aerogels. Taking the electrooxidation of small organic molecules (such as methanol and ethanol) by the resulting Au m-n and Au m-n @Pd aerogels as examples, it is found that surface facets of metallic aerogels with excellent performance can be regulated to realize preferential surface facets for methanol oxidation and ethanol oxidation, respectively. Moreover, they also indeed simultaneously bear high activity and excellent stability. Furthermore, their activities and stability are also highly dependent on the area ratio of active facets and inactive facets on their surfaces, respectively, and these ratios are varied via the mismatch of sizes of adjacent nanoparticles. Thus, this work not only demonstrates the realization of the regulation of the surface facets of metallic aerogels by size-dependent localized Ostwald ripening, but also will open up a new way to improve electrocatalytic performance of three-dimensional metallic aerogels by surface regulation.

  12. A review of drug delivery systems for capsule endoscopy.

    PubMed

    Munoz, Fredy; Alici, Gursel; Li, Weihua

    2014-05-01

    The development of a highly controllable drug delivery system (DDS) for capsule endoscopy has become an important field of research due to its promising applications in therapeutic treatment of diseases in the gastrointestinal (GI) tract and drug absorption studies. Several factors need to be considered to establish the minimum requirements for a functional DDS. Environmental factors of the GI tract and also pharmaceutical factors can help determine the requirements to be met by a DDS in an endoscopic capsule. In order to minimize the influence of such factors on the performance of an effective DDS, at least two mechanisms should be incorporated into a capsule endoscope: an anchoring mechanism to control the capsule position and a drug release mechanism to control variables such as the drug release rate, number of doses and amount of drug released. The implementation of such remotely actuated mechanisms is challenging due to several constraints, including the limited space available in a swallowable capsule endoscope and the delicate and complex environment within the GI tract. This paper presents a comprehensive overview of existing DDS. A comparison of such DDS for capsule endoscopy based on the minimum DDS requirements is presented and future work is also discussed. Copyright © 2013 Elsevier B.V. All rights reserved.

  13. Magnetically Actuated Soft Capsule With the Multimodal Drug Release Function

    PubMed Central

    Yim, Sehyuk; Goyal, Kartik; Sitti, Metin

    2014-01-01

    In this paper, we present a magnetically actuated multimodal drug release mechanism using a tetherless soft capsule endoscope for the treatment of gastric disease. Because the designed capsule has a drug chamber between both magnetic heads, if it is compressed by the external magnetic field, the capsule could release a drug in a specific position locally. The capsule is designed to release a drug in two modes according to the situation. In the first mode, a small amount of drug is continuously released by a series of pulse type magnetic field (0.01–0.03 T). The experimental results show that the drug release can be controlled by the frequency of the external magnetic pulse. In the second mode, about 800 mm3 of drug is released by the external magnetic field of 0.07 T, which induces a stronger magnetic attraction than the critical force for capsule’s collapsing. As a result, a polymeric coating is formed around the capsule. The coated area is dependent on the drug viscosity. This paper presents simulations and various experiments to evaluate the magnetically actuated multimodal drug release capability. The proposed soft capsules could be used as minimally invasive tetherless medical devices with therapeutic capability for the next generation capsule endoscopy. PMID:25378896

  14. Asymptomatic bronchial aspiration and prolonged retention of a capsule endoscope: a case report.

    PubMed

    Pezzoli, Alessandro; Fusetti, Nadia; Carella, Alessandra; Gullini, Sergio

    2011-08-02

    Capsule endoscopy has, over the last few years, become a first-line test to visualize the mucosa of the small intestine. This technique is generally considered safe and does not cause discomfort for patients. However, although patients may have difficulty in swallowing the capsule, bronchial aspiration of a capsule endoscope is a very rare complication. We report the case of an 82-year-old man who experienced prolonged bronchial aspiration of a capsule endoscope without relevant symptoms, followed by a spontaneous return of the capsule to the gastrointestinal tract. An 82-year-old Caucasian man was referred to our unit from another local hospital to undergo capsule endoscopy. He swallowed the capsule without any apparent difficulties and did not show any overt symptoms. The following day, when we reviewed the capsule endoscopy images, we realized that the capsule was in the bronchial system and remained there for the duration of the study. An urgent X-ray of the chest confirmed the presence of the capsule in the left side of the bronchopulmonary tree. Two days later a repeat chest X-ray showed the capsule in the right bronchus. After two days the capsule was retrieved in the feces. Our patient remained asymptomatic during the entire admission period. Aspiration of a capsule endoscope is a rare complication; to the best of our knowledge this is the first reported case in which a capsule endoscope remained for six days in the bronchial system of a patient without causing airway compromise or pneumonitis and spontaneously returned to the gastrointestinal tract.

  15. Description and Nomenclature of Neisseria meningitidis Capsule Locus

    PubMed Central

    Claus, Heike; Jiang, Ying; Bennett, Julia S.; Bratcher, Holly B.; Jolley, Keith A.; Corton, Craig; Care, Rory; Poolman, Jan T.; Zollinger, Wendell D.; Frasch, Carl E.; Stephens, David S.; Feavers, Ian; Frosch, Matthias; Parkhill, Julian; Vogel, Ulrich; Quail, Michael A.; Bentley, Stephen D.; Maiden, Martin C.J.

    2013-01-01

    Pathogenic Neisseria meningitidis isolates contain a polysaccharide capsule that is the main virulence determinant for this bacterium. Thirteen capsular polysaccharides have been described, and nuclear magnetic resonance spectroscopy has enabled determination of the structure of capsular polysaccharides responsible for serogroup specificity. Molecular mechanisms involved in N. meningitidis capsule biosynthesis have also been identified, and genes involved in this process and in cell surface translocation are clustered at a single chromosomal locus termed cps. The use of multiple names for some of the genes involved in capsule synthesis, combined with the need for rapid diagnosis of serogroups commonly associated with invasive meningococcal disease, prompted a requirement for a consistent approach to the nomenclature of capsule genes. In this report, a comprehensive description of all N. meningitidis serogroups is provided, along with a proposed nomenclature, which was presented at the 2012 XVIIIth International Pathogenic Neisseria Conference. PMID:23628376

  16. Facet-Dependent Property of Sequentially Deposited Perovskite Thin Films: Chemical Origin and Self-Annihilation.

    PubMed

    Zhang, Tiankai; Long, Mingzhu; Yan, Keyou; Zeng, Xiaoliang; Zhou, Fengrui; Chen, Zefeng; Wan, Xi; Chen, Kun; Liu, Pengyi; Li, Faming; Yu, Tao; Xie, Weiguang; Xu, Jianbin

    2016-11-30

    Quantification of intergrain length scale properties of CH 3 NH 3 PbI 3 (MAPbI 3 ) can provide further understanding of material physics, leading to improved device performance. In this work, we noticed that two typical types of facets appear in sequential deposited perovskite (SDP) films: smooth and steplike morphologies. By mapping the surface potential as well as the photoluminescence (PL) peak position, we revealed the heterogeneity of SDP thin films that smooth facets are almost intrinsic with a PL peak at 775 nm, while the steplike facets are p-type-doped with 5-nm blue-shifted PL peak. Considering the reaction process, we propose that the smooth facets have well-defined crystal lattices that resulted from the interfacial reaction between MAI and PbI 2 domains containing low trap states density. The steplike facets are MAI-rich originated from the grain boundaries of PbI 2 film and own more trap states. Conversion of steplike facets to smooth facets can be controlled by increasing the reaction time through Ostwald ripening. The improved stability, photoresponsivity up to 0.3 A/W, on/off ratio up to 3900, and decreased photo response time to ∼160 μs show that the trap states can be annihilated effectively to improve the photoelectrical conversion with prolonged reaction time and elimination of steplike facets. Our findings demonstrate the relationship between the facet heterogeneity of SDP films and crystal growth process for the first time, and imply that the systematic control of crystal grain modification will enable amelioration of crystallinity for more-efficient perovskite photoelectrical applications.

  17. Fiber facet gratings for high power fiber lasers

    NASA Astrophysics Data System (ADS)

    Vanek, Martin; Vanis, Jan; Baravets, Yauhen; Todorov, Filip; Ctyroky, Jiri; Honzatko, Pavel

    2017-12-01

    We numerically investigated the properties of diffraction gratings designated for fabrication on the facet of an optical fiber. The gratings are intended to be used in high-power fiber lasers as mirrors either with a low or high reflectivity. The modal reflectance of low reflectivity polarizing grating has a value close to 3% for TE mode while it is significantly suppressed for TM mode. Such a grating can be fabricated on laser output fiber facet. The polarizing grating with high modal reflectance is designed as a leaky-mode resonant diffraction grating. The grating can be etched in a thin layer of high index dielectric which is sputtered on fiber facet. We used refractive index of Ta2O5 for such a layer. We found that modal reflectance can be close to 0.95 for TE polarization and polarization extinction ratio achieves 18 dB. Rigorous coupled wave analysis was used for fast optimization of grating parameters while aperiodic rigorous coupled wave analysis, Fourier modal method and finite difference time domain method were compared and used to compute modal reflectance of designed gratings.

  18. The Effects of Knee Joint Effusion on Quadriceps Electromyography During Jogging

    PubMed Central

    Torry, Michael R.; Decker, Michael J.; Millett, Peter J.; Steadman, J. Richard; Sterett, William I.

    2005-01-01

    To investigate and describe the influence of intra-articular effusion on knee joint kinematics and electromyographic (EMG) profiles during jogging. Thirteen individuals underwent a 20 cc 0.9% saline insufflation of the knee joint capsule and completed 8 jogging trials. Stance phase, sagittal plane knee joint kinematics and thigh muscular EMG profiles were compared pre- and post-insufflation utilizing a paired t-test ( = 0.05). Mild knee effusion caused a reduction in vastus medialis (p = 0.005) and lateralis (p = 0.006) EMG activity. The rectus femoris, biceps femoris and medial hamstring muscles did not exhibit changes due to this protocol. There were no changes in the sagittal plane knee joint kinematic pattern. Twenty cc effusion can cause quadriceps inhibition in the vastus medialis and the vastus lateralis in otherwise healthy individuals during jogging. This study provides baseline data for the effects of mild knee joint effusion on thigh musculature during jogging. Key Points 20 cc of knee effusion can cause vastus medialis and lateralis inhibition as noted by decreases in EMG amplitude. This effusion does not appear to alter sagittal plane knee joint kinematics during jogging. This finding if different from previous work investigating knee joint kinematic changes during a less dynamic activity (gait) with 20 cc of effusion. PMID:24431955

  19. Residual mercury content and leaching of mercury and silver from used amalgam capsules.

    PubMed

    Stone, M E; Pederson, E D; Cohen, M E; Ragain, J C; Karaway, R S; Auxer, R A; Saluta, A R

    2002-06-01

    The objective of this investigation was to carry out residual mercury (Hg) determinations and toxicity characteristic leaching procedure (TCLP) analysis of used amalgam capsules. For residual Hg analysis, 25 capsules (20 capsules for one brand) from each of 10 different brands of amalgam were analyzed. Total residual Hg levels per capsule were determined using United States Environmental Protection Agency (USEPA) Method 7471. For TCLP analysis, 25 amalgam capsules for each of 10 brands were extracted using a modification of USEPA Method 1311. Hg analysis of the TCLP extracts was done with USEPA Method 7470A. Analysis of silver (Ag) concentrations in the TCLP extract was done with USEPA Method 6010B. Analysis of the residual Hg data resulted in the segregation of brands into three groups: Dispersalloy capsules, Group A, retained the most Hg (1.225 mg/capsule). These capsules were the only ones to include a pestle. Group B capsules, Valliant PhD, Optaloy II, Megalloy and Valliant Snap Set, retained the next highest amount of Hg (0.534-0.770 mg/capsule), and were characterized by a groove in the inside of the capsule. Group C, Tytin regular set double-spill, Tytin FC, Contour, Sybraloy regular set, and Tytin regular set single-spill retained the least amount of Hg (0.125-0.266 mg/capsule). TCLP analysis of the triturated capsules showed Sybraloy and Contour leached Hg at greater than the 0.2 mg/l Resource Conservation and Recovery Act (RCRA) limit. This study demonstrated that residual mercury may be related to capsule design features and that TCLP extracts from these capsules could, in some brands, exceed RCRA Hg limits, making their disposal problematic. At current RCRA limits, the leaching of Ag is not a problem.

  20. A comparative study on liquid core formulation on the diameter on the alginate capsules

    NASA Astrophysics Data System (ADS)

    Ong, Hui-Yen; Lee, Boon-Beng; Radzi, AkmalHadi Ma'; Zakaria, Zarina; Chan, Eng-Seng

    2015-08-01

    Liquid core capsule has vast application in biotechnology related industries such as pharmaceutical, medical, agriculture and food. Formulation of different types of capsule was important to determine the performance of the capsule. Generally, the liquid core capsule with different formulations generated different size of capsule.Therefore, the aim of this project is to investigate the effect of different liquid core solution formulations on the diameter of capsule. The capsule produced by extruding liquid core solutions into sodium alginate solution. Three types of liquid core solutions (chitosan, xanthan gum, polyethylene glycol (PEG)) were investigated. The results showed that there is significant change in capsule diameter despite in different types of liquid core solution were used and a series of capsule range in diameter of 3.1 mm to 4.5 mm were produced. Alginate capsule with chitosan formulation appeared to be the largest capsule among all.

  1. [Exploring the clinical characters of Shugan Jieyu capsule through text mining].

    PubMed

    Pu, Zheng-Ping; Xia, Jiang-Ming; Xie, Wei; He, Jin-Cai

    2017-09-01

    The study was main to explore the clinical characters of Shugan Jieyu capsule through text mining. The data sets of Shugan Jieyu capsule were downloaded from CMCC database by the method of literature retrieved from May 2009 to Jan 2016. Rules of Chinese medical patterns, diseases, symptoms and combination treatment were mined out by data slicing algorithm, and they were demonstrated in frequency tables and two dimension based network. Then totally 190 literature were recruited. The outcomess suggested that SC was most frequently correlated with liver Qi stagnation. Primary depression, depression due to brain disease, concomitant depression followed by physical diseases, concomitant depression followed by schizophrenia and functional dyspepsia were main diseases treated by Shugan Jieyu capsule. Symptoms like low mood, psychic anxiety, somatic anxiety and dysfunction of automatic nerve were mainy relieved bv Shugan Jieyu capsule.For combination treatment. Shugan Jieyu capsule was most commonly used with paroxetine, sertraline and fluoxetine. The research suggested that syndrome types and mining results of Shugan Jieyu capsule were almost the same as its instructions. Syndrome of malnutrition of heart spirit was the potential Chinese medical pattern of Shugan Jieyu capsule. Primary comorbid anxiety and depression, concomitant comorbid anxiety and depression followed by physical diseases, and postpartum depression were potential diseases treated by Shugan Jieyu capsule.For combination treatment, Shugan Jieyu capsule was most commonly used with paroxetine, sertraline and fluoxetine. Copyright© by the Chinese Pharmaceutical Association.

  2. Surface Area of Patellar Facets: Inferential Statistics in the Iraqi Population

    PubMed Central

    Al-Zamili, Zaid; Omar, Rawan

    2017-01-01

    Background. The patella is the largest sesamoid bone in the body; its three-dimensional complexity necessitates biomechanical perfection. Numerous pathologies occur at the patellofemoral unit which may end in degenerative changes. This study aims to test the presence of statistical correlation between the surface areas of patellar facets and other patellar morphometric parameters. Materials and Methods. Forty dry human patellae were studied. The morphometry of each patella was measured using a digital Vernier Caliper, electronic balance, and image analyses software known as ImageJ. The patellar facetal surface area was correlated with patellar weight, height, width, and thickness. Results. Inferential statistics proved the existence of linear correlation of total facetal surface area and patellar weight, height, width, and thickness. The correlation was strongest for surface area versus patellar weight. The lateral facetal area was found persistently larger than the medial facetal area, the p value was found to be <0.001 (one-tailed t-test) for right patellae, and another significant p value of < 0.001 (one-tailed t-test) was found for left patellae. Conclusion. These data are vital for the restoration of the normal biomechanics of the patellofemoral unit; these are to be consulted during knee surgeries and implant designs and can be of an indispensable anthropometric, interethnic, and biometric value. PMID:28348891

  3. The double capsules in macro-textured breast implants.

    PubMed

    Giot, Jean-Philippe; Paek, Laurence S; Nizard, Nathanael; El-Diwany, Mostafa; Gaboury, Louis A; Nelea, Monica; Bou-Merhi, Joseph S; Harris, Patrick G; Danino, Michel A

    2015-10-01

    Breast implants are amongst the most widely used types of permanent implants in modern medicine and have both aesthetic and reconstructive applications with excellent biocompatibility. The double capsule is a complication associated with textured prostheses that leads to implant displacement; however, its etiology has yet to be elucidated. In this study, 10 double capsules were sampled from breast expander implants for in-depth analysis; histologically, the inner capsular layer demonstrated highly organized collagen in sheets with delamination of fibers. At the prosthesis interface (PI) where the implant shell contacts the inner capsular layer, scanning electron microscopy (SEM) revealed a thin layer which mirrored the three-dimensional characteristics of the implant texture; the external surface of the inner capsular layer facing the intercapsular space (ICS) was flat. SEM examination of the inner capsule layer revealed both a large bacterial presence as well as biofilm deposition at the PI; a significantly lower quantity of bacteria and biofilm were found at the ICS interface. These findings suggest that the double capsule phenomenon's etiopathogenesis is of mechanical origin. Delamination of the periprosthetic capsule leads to the creation of the ICS; the maintained separation of the 2 layers subsequently alters the biostability of the macro-textured breast implant. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Versatile Loading of Diverse Cargo into Functional Polymer Capsules.

    PubMed

    Richardson, Joseph J; Maina, James W; Ejima, Hirotaka; Hu, Ming; Guo, Junling; Choy, Mei Y; Gunawan, Sylvia T; Lybaert, Lien; Hagemeyer, Christoph E; De Geest, Bruno G; Caruso, Frank

    2015-02-01

    Polymer microcapsules are of particular interest for applications including self-healing coatings, catalysis, bioreactions, sensing, and drug delivery. The primary way that polymer capsules can exhibit functionality relevant to these diverse fields is through the incorporation of functional cargo in the capsule cavity or wall. Diverse functional and therapeutic cargo can be loaded into polymer capsules with ease using polymer-stabilized calcium carbonate (CaCO 3 ) particles. A variety of examples are demonstrated, including 15 types of cargo, yielding a toolbox with effectively 500+ variations. This process uses no harsh reagents and can take less than 30 min to prepare, load, coat, and form the hollow capsules. For these reasons, it is expected that the technique will play a crucial role across scientific studies in numerous fields.

  5. Deformation of an elastic capsule in a uniform electric field

    NASA Astrophysics Data System (ADS)

    Karyappa, Rahul B.; Deshmukh, Shivraj. D.; Thaokar, Rochish. M.

    2014-12-01

    The deformation of a thin elastic capsule subjected to a uniform electric field is investigated in the Stokes flow regime. The electrohydrodynamic flow is analyzed using a perfect conductor and a perfect dielectric model for the capsule and the fluid phase, respectively. A theoretical analysis is carried out using an asymptotic expansion in the electric capillary number (Ca) (a ratio of the electric stress to the elastic tension) in the small deformation limit using the finite deformation Hooke's law. The analysis is used to determine the elasticity of polysiloxane capsules suspended in oil, the deformation of which is obtained using videography. The boundary element method is implemented to seek numerical solutions to the hydrodynamic, elastic, and electrostatics equations. The finite deformation Hooke's law, the Mooney-Rivlin, and Skalak's model for elasticity are employed. The effect of electric capillary number, unstressed geometry, and the type of membrane material on the deformation of a capsule is presented in the high Ca number limit using numerical simulation. Capsules synthesized with higher monomer concentration displayed electric stress induced wrinkling process at high electric field strengths. Burst of a capsule is characterized by poration of the polymer membrane, which could be symmetric or asymmetric at the two poles, depending upon the value of the capillary number. The results should be useful in understanding the response of elastic capsules such as red blood cells and polymerized membranes, to an electric field, in applications such as electrodeformation and electroporation. It also provides a theoretical framework for a possible way of determining the elastic parameters of a capsule.

  6. Glenohumeral corticosteroid injections in adhesive capsulitis: a systematic search and review

    PubMed Central

    Song, Amos; Higgins, Laurence D.; Newman, Joel; Jain, Nitin B.

    2014-01-01

    OBJECTIVES To assess the literature on outcomes of corticosteroid injections for adhesive capsulitis, and in particular, image-guided corticosteroid injections. TYPE Systematic search and review LITERATURE SURVEY The databases used were PubMed (1966-present), Embase (1947-present), Web of Science (1900–present), and the Cochrane Central Register of Controlled Trials. Upon reviewing full text articles of these studies, a total of 25 studies were identified for inclusion. The final yield included 7 prospective studies, 16 randomized trials, and 2 retrospective studies. METHODOLOGY This systematic review was formatted using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Study criteria were limited to clinical trials, prospective studies, and retrospective studies that specifically evaluated intra-articular corticosteroid injections, both alone and in combination with other treatment modalities, for shoulder adhesive capsulitis. We included studies that were not randomized control trials because our review was not a meta-analysis. Data items extracted from each study included: study design, study population, mean patient age, duration of study, duration of symptoms, intervention, single or multiple injections, location of injections, control population, follow up duration, and outcome measurements. A percent change in outcome measures was calculated when corresponding data was available. Risk of bias in individual studies was assessed when appropriate. SYNTHESIS All studies involved at least one corticosteroid injection intended for placement in the glenohumeral joint but only eight studies used image-guidance for all injections. Seven of these studies reported statistically significant improvements in ROM at 12 weeks of follow-up or earlier. Ninety-two percent of all studies documented a greater improvement in either visual analog pain scores or range of motion after corticosteroid injections in the first 1–6 weeks as

  7. The morphological characteristics of the antebrachiocarpal joint of the cheetah (Acinonyx jubatus).

    PubMed

    Ohale, L O C; Groenewald, H B

    2003-03-01

    A morphological study of the structures of the antebrachiocarpal (AC) joint of the cheetah was carded out by dissection of eight forelimbs obtained from four adult cheetahs culled from the Kruger National Park, Republic of South Africa. The aim was to evaluate the deviations of this joint from the normal feline pattern and to consider their possible relationship to the cheetah's adaptation to speed. Although published data on the AC joint of the other felids show general resemblance to that of the cheetah, there are nevertheless slight, but significant variations and modifications which tend to suggest adaptation to speed. The shafts of the radius and ulna of the cheetah are relatively straight and slender, with poorly developed distal ends. The ulnar notch is reduced to a very shallow concavity while the corresponding ulnar facet is a barely noticeable convexity, separated from the distal ulnar articular facet by an ill-defined groove. The movement of the distal radio-ulnar joint is highly restricted by the presence of a fibro-cartilaginous structure and a strong interrosseous membrane, limiting pronation and supination normally achieved by the rotation of the radius around the ulna. The extensor grooves at the distal extremity of the radius are deep and narrow and are guarded by prominent ridges. A thick extensor retinaculum anchors the strong extensor tendons in these grooves. The distal articular surface of the radius is concave in all directions except at the point where it moves into its stylold process. At this point it is convex in the dorsopalmar direction, with a surface that is rather deep and narrow. The proximal row of carpal bones presents a strongly convex surface, which is more pronounced in the dorsopalmar direction with the greatest convexity on the lateral aspect. Medially, there is a ridge-like concavity across the base of the tubercle, which rocks on the flexor surface of the radius, limiting excessive flexion as well as restricting lateral

  8. Tailoring molecular specificity toward a crystal facet: a lesson from biorecognition toward Pt{111}.

    PubMed

    Ruan, Lingyan; Ramezani-Dakhel, Hadi; Chiu, Chin-Yi; Zhu, Enbo; Li, Yujing; Heinz, Hendrik; Huang, Yu

    2013-02-13

    Surfactants with preferential adsorption to certain crystal facets have been widely employed to manipulate morphologies of colloidal nanocrystals, while mechanisms regarding the origin of facet selectivity remain an enigma. Similar questions exist in biomimetic syntheses concerning biomolecular recognition to materials and crystal surfaces. Here we present mechanistic studies on the molecular origin of the recognition toward platinum {111} facet. By manipulating the conformations and chemical compositions of a platinum {111} facet specific peptide, phenylalanine is identified as the dominant motif to differentiate {111} from other facets. The discovered recognition motif is extended to convert nonspecific peptides into {111} specific peptides. Further extension of this mechanism allows the rational design of small organic molecules that demonstrate preferential adsorption to the {111} facets of both platinum and rhodium nanocrystals. This work represents an advance in understanding the organic-inorganic interfacial interactions in colloidal systems and paves the way to rational and predictable nanostructure modulations for many applications.

  9. Wireless capsule endoscopy: perspectives beyond gastrointestinal bleeding.

    PubMed

    Redondo-Cerezo, Eduardo; Sánchez-Capilla, Antonio Damián; De La Torre-Rubio, Paloma; De Teresa, Javier

    2014-11-14

    Wireless capsule endoscopy (CE) is a technology developed for the endoscopic exploration of the small bowel. The first capsule model was approved by the Food and Drug Administration in 2001, and its first and essential indication was occult gastrointestinal (GI) bleeding. Over subsequent years, this technology has been refined to provide superior resolution, increased battery life, and capabilities to view different parts of the GI tract. Indeed, cases for which CE proved useful have increased significantly over the last few years, with new indications for the small bowel and technical improvements that have expanded its use to other parts of the GI tract, including the esophagus and colon. The main challenges in the development of CE are new devices with the ability to provide therapy, air inflation for a better vision of the small bowel, biopsy sampling systems attached to the capsule and the possibility to guide and move the capsule with an external motion control. In this article we review the current and new indications of CE, and the evolving technological changes shaping this technology, which has a promising potential in the coming future of gastroenterology.

  10. Method of forming capsules containing a precise amount of material

    DOEpatents

    Grossman, Mark W.; George, William A.; Maya, Jakob

    1986-01-01

    A method of forming a sealed capsule containing a submilligram quantity of mercury or the like, the capsule being constructed from a hollow glass tube, by placing a globule or droplet of the mercury in the tube. The tube is then evacuated and sealed and is subsequently heated so as to vaporize the mercury and fill the tube therewith. The tube is then separated into separate sealed capsules by heating spaced locations along the tube with a coiled heating wire means to cause collapse spaced locations therealong and thus enable separation of the tube into said capsules.

  11. Method of forming capsules containing a precise amount of material

    DOEpatents

    Grossman, M.W.; George, W.A.; Maya, J.

    1986-06-24

    A method of forming a sealed capsule containing a submilligram quantity of mercury or the like, the capsule being constructed from a hollow glass tube, by placing a globule or droplet of the mercury in the tube. The tube is then evacuated and sealed and is subsequently heated so as to vaporize the mercury and fill the tube therewith. The tube is then separated into separate sealed capsules by heating spaced locations along the tube with a coiled heating wire means to cause collapse spaced locations there along and thus enable separation of the tube into said capsules. 7 figs.

  12. Supercooling Water in Cylindrical Capsules

    NASA Astrophysics Data System (ADS)

    Guzman, J. J. Milón; Braga, S. L.

    2005-11-01

    An experimental apparatus was developed to investigate the supercooling phenomenon of water inside cylindrical capsules used for a cold storage process. The coolant is a water-alcohol mixture controlled by a constant temperature bath (CTB). Temperatures varying with time are measured inside and outside the capsule. Cylinders with an internal diameter and thickness of 45 and 1.5 mm, respectively, were made from four different materials: acrylic, PVC, brass, and aluminum. The supercooling period of the water and the nucleation temperature were investigated for different coolant temperatures. The supercooling and nucleation probabilities are shown as a function of the coolant temperature for the four different materials.

  13. A Systems Biology Approach to Synovial Joint Lubrication in Health, Injury, and Disease

    PubMed Central

    Hui, Alexander Y.; McCarty, William J.; Masuda, Koichi; Firestein, Gary S.; Sah, Robert L.

    2013-01-01

    The synovial joint contains synovial fluid (SF) within a cavity bounded by articular cartilage and synovium. SF is a viscous fluid that has lubrication, metabolic, and regulatory functions within synovial joints. SF contains lubricant molecules, including proteoglycan-4 and hyaluronan. SF is an ultrafiltrate of plasma with secreted contributions from cell populations lining and within the synovial joint space, including chondrocytes and synoviocytes. Maintenance of normal SF lubricant composition and function are important for joint homeostasis. In osteoarthritis, rheumatoid arthritis, and joint injury, changes in lubricant composition and function accompany alterations in the cytokine and growth factor environment and increased fluid and molecular transport through joint tissues. Thus, understanding the synovial joint lubrication system requires a multi-faceted study of the various parts of the synovial joint and their interactions. Systems biology approaches at multiple scales are being used to describe the molecular, cellular, and tissue components and their interactions that comprise the functioning synovial joint. Analyses of the transcriptome and proteome of SF, cartilage, and synovium suggest that particular molecules and pathways play important roles in joint homeostasis and disease. Such information may be integrated with physicochemical tissue descriptions to construct integrative models of the synovial joint that ultimately may explain maintenance of health, recovery from injury, or development and progression of arthritis. PMID:21826801

  14. Psychopathy, attention, and oddball target detection: New insights from PCL-R facet scores.

    PubMed

    Anderson, Nathaniel E; Steele, Vaughn R; Maurer, J Michael; Bernat, Edward M; Kiehl, Kent A

    2015-09-01

    Psychopathy is a disorder accompanied by cognitive deficits including abnormalities in attention. Prior studies examining cognitive features of psychopaths using ERPs have produced some inconsistent results. We examined psychopathy-related differences in ERPs during an auditory oddball task in a sample of incarcerated adult males. We extend previous work by deriving ERPs with principal component analysis (PCA) and relate these to the four facets of Hare's Psychopathy Checklist Revised (PCL-R). Features of psychopathy were associated with increased target N1 amplitude (facets 1, 4), decreased target P3 amplitude (facet 1), and reduced slow wave amplitude for frequent standard stimuli (facets 1, 3, 4). We conclude that employing PCA and examining PCL-R facets improve sensitivity and help clarify previously reported associations. Furthermore, attenuated slow wave during standards may be a novel marker for psychopaths' abnormalities in attention. © 2015 Society for Psychophysiological Research.

  15. Facets of emotional awareness and associations with emotion regulation and depression.

    PubMed

    Boden, Matthew Tyler; Thompson, Renee J

    2015-06-01

    Emotion theories posit that effective emotion regulation depends upon the nuanced information provided by emotional awareness; attending to and understanding one's own emotions. Additionally, the strong associations between facets of emotional awareness and various forms of psychopathology may be partially attributable to associations with emotion regulation. These logically compelling hypotheses are largely uninvestigated, including which facets compose emotional awareness and how they relate to emotion regulation strategies and psychopathology. We used exploratory structural equation modeling of individual difference measures among a large adult sample (n = 919) recruited online. Results distinguished 4 facets of emotional awareness (type clarity, source clarity, involuntary attention to emotion, and voluntary attention to emotion) that were differentially associated with expressive suppression, acceptance of emotions, and cognitive reappraisal. Facets were associated with depression both directly and indirectly via associations with emotion regulation strategies. We discuss implications for theory and research on emotional awareness, emotion regulation, and psychopathology. (c) 2015 APA, all rights reserved).

  16. FACETS: using open data to measure community social determinants of health.

    PubMed

    Cantor, Michael N; Chandras, Rajan; Pulgarin, Claudia

    2018-04-01

    To develop a dataset based on open data sources reflective of community-level social determinants of health (SDH). We created FACETS (Factors Affecting Communities and Enabling Targeted Services), an architecture that incorporates open data related to SDH into a single dataset mapped at the census-tract level for New York City. FACETS (https://github.com/mcantor2/FACETS) can be easily used to map individual addresses to their census-tract-level SDH. This dataset facilitates analysis across different determinants that are often not easily accessible. Wider access to open data from government agencies at the local, state, and national level would facilitate the aggregation and analysis of community-level determinants. Timeliness of updates to federal non-census data sources may limit their usefulness. FACETS is an important first step in standardizing and compiling SDH-related data in an open architecture that can give context to a patient's condition and enable better decision-making when developing a plan of care.

  17. Video-based measurements for wireless capsule endoscope tracking

    NASA Astrophysics Data System (ADS)

    Spyrou, Evaggelos; Iakovidis, Dimitris K.

    2014-01-01

    The wireless capsule endoscope is a swallowable medical device equipped with a miniature camera enabling the visual examination of the gastrointestinal (GI) tract. It wirelessly transmits thousands of images to an external video recording system, while its location and orientation are being tracked approximately by external sensor arrays. In this paper we investigate a video-based approach to tracking the capsule endoscope without requiring any external equipment. The proposed method involves extraction of speeded up robust features from video frames, registration of consecutive frames based on the random sample consensus algorithm, and estimation of the displacement and rotation of interest points within these frames. The results obtained by the application of this method on wireless capsule endoscopy videos indicate its effectiveness and improved performance over the state of the art. The findings of this research pave the way for a cost-effective localization and travel distance measurement of capsule endoscopes in the GI tract, which could contribute in the planning of more accurate surgical interventions.

  18. Cervical facet arthropathy and occipital neuralgia: headache culprits.

    PubMed

    Hoppenfeld, J D

    2010-12-01

    Cervicogenic headache (CH) is pain referred from the neck. Two common causes are cervical facet arthropathy and occipital neuralgia. Clinical diagnosis is difficult because of the overlying features between primary headaches such as migraine, tension-type headache, and CH. Interventional pain physicians have focused on supporting the clinical diagnosis of CH with confirmatory blocks. The treatment of cervical facet arthropathy as the source of CH is best approached with a multidimensional plan focusing on physical therapy and/or manual therapy. The effective management of occipital neuralgia remains challenging, but both injections and neuromodulation are promising options.

  19. Medical capsule robots: A renaissance for diagnostics, drug delivery and surgical treatment.

    PubMed

    Mapara, Sanyat S; Patravale, Vandana B

    2017-09-10

    The advancements in electronics and the progress in nanotechnology have resulted in path breaking development that will transform the way diagnosis and treatment are carried out currently. This development is Medical Capsule Robots, which has emerged from the science fiction idea of robots travelling inside the body to diagnose and cure disorders. The first marketed capsule robot was a capsule endoscope developed to capture images of the gastrointestinal tract. Today, varieties of capsule endoscopes are available in the market. They are slightly larger than regular oral capsules, made up of a biocompatible case and have electronic circuitry and mechanisms to capture and transmit images. In addition, robots with diagnostic features such as in vivo body temperature detection and pH monitoring have also been launched in the market. However, a multi-functional unit that will diagnose and cure diseases inside the body has not yet been realized. A remote controlled capsule that will undertake drug delivery and surgical treatment has not been successfully launched in the market. High cost, inadequate power supply, lack of control over drug release, limited space for drug storage on the capsule, inadequate safety and no mechanisms for active locomotion and anchoring have prevented their entry in the market. The capsule robots can revolutionize the current way of diagnosis and treatment. This paper discusses in detail the applications of medical capsule robots in diagnostics, drug delivery and surgical treatment. In diagnostics, detailed analysis has been presented on wireless capsule endoscopes, issues associated with the marketed versions and their corresponding solutions in literature. Moreover, an assessment has been made of the existing state of remote controlled capsules for targeted drug delivery and surgical treatment and their future impact is predicted. Besides the need for multi-functional capsule robots and the areas for further research have also been

  20. Job Stress, Employee Health, and Organizational Effectiveness: A Facet Analysis, Model, and Literature Review.

    ERIC Educational Resources Information Center

    Beehr, Terry A.; Newman, John E.

    1978-01-01

    The empirical research on job stress and employee health is reviewed within the context of six facets (environmental, personal, process, human consequences, organizational consequences, and time) of a seven facet conceptualization of the job stress-employee health research domain. Models are proposed for tying the facets together. (Author/SJL)

  1. Phenotypic Heterogeneity in Expression of the K1 Polysaccharide Capsule of Uropathogenic Escherichia coli and Downregulation of the Capsule Genes during Growth in Urine.

    PubMed

    King, Jane E; Aal Owaif, Hasan A; Jia, Jia; Roberts, Ian S

    2015-07-01

    Uropathogenic Escherichia coli (UPEC) is the major causative agent of uncomplicated urinary tract infections (UTI). The K1 capsule on the surface of UPEC strains is a key virulence factor, and its expression may be important in the onset and progression of UTI. In order to understand capsule expression in more detail, we analyzed its expression in the UPEC strain UTI89 during growth in rich medium (LB medium) and urine and during infection of a bladder epithelial cell line. Comparison of capsule gene transcription using a chromosomal gfp reporter fusion showed a significant reduction in transcription during growth in urine compared to that during growth in LB medium. When examined at the single-cell level, following growth in both media, capsule gene expression appears to be heterogeneous, with two distinct green fluorescent protein (GFP)-expressing populations. Using anti-K1 antibody, we showed that this heterogeneity in gene expression results in two populations of encapsulated and unencapsulated cells. We demonstrated that the capsule hinders attachment to and invasion of epithelial cells and that the unencapsulated cells within the population preferentially adhere to and invade bladder epithelial cells. We found that once internalized, UTI89 starts to produce capsule to aid in its intracellular survival and spread. We propose that this observed phenotypic diversity in capsule expression is a fitness strategy used by the bacterium to deal with the constantly changing environment of the urinary tract. Copyright © 2015 King et al.

  2. Antiobesity effects of Undaria lipid capsules prepared with scallop phospholipids.

    PubMed

    Okada, Tomoko; Mizuno, Yasuyuki; Sibayama, Shinichi; Hosokawa, Masashi; Miyashita, Kazuo

    2011-01-01

    Based on previous research findings, a capsule was developed containing n-3 polyunsaturated fatty acid rich scallop phospholipids (PLs) with an incorporation of brown seaweed (Undaria pinnatifida) lipids (ULs) containing fucoxanthin. The antiobesity effects of the capsules were evaluated with an animal model using 3-wk-old male KK-A(y) mice. Each group received different combinations of lipid (UL, PL, UL + PL, or UL + PL capsule) either incorporated into the diet or into drinking water. Animals were sacrificed after a 4-wk experimental feeding period, and adipose tissues and organs were dissected and weighed. Blood samples were obtained to determine plasma lipid profiles. Uncoupling protein 1 (UCP1) mRNA expression levels were determined by real-time polymerase chain reaction analysis, and UCP1 expression was determined by western blotting analysis. Treatment with either UL alone or UL + PL (capsule) through drinking water resulted in a significant reduction in body weight, compared to the control group. The total white adipose tissue weight of mice fed the UL + PL capsule in drinking water was significantly reduced. Both UCP1 and UCP1 mRNA expression in epididymal fat from mice fed the capsule were significantly higher than in the control group. These results suggest that incorporation of UL into scallop-derived PL by means of capsulation may lead to an additive increase in the antiobesity properties of these bioactive lipids.

  3. Water Landing Characteristics of a Reentry Capsule

    NASA Technical Reports Server (NTRS)

    1958-01-01

    Experimental and theoretical investigations have been made to determine the water-landing characteristics of a conical-shaped reentry capsule having a segment of a sphere as the bottom. For the experimental portion of the investigation, a 1/12-scale model capsule and a full-scale capsule were tested for nominal flight paths of 65 deg and 90 deg (vertical), a range of contact attitudes from -30 deg to 30 deg, and a full-scale vertical velocity of 30 feet per second at contact. Accelerations were measured by accelerometers installed at the centers of gravity of the model and full-scale capsules. For the model test the accelerations were measured along the X-axis (roll) and Z-axis (yaw) and for the full-scale test they were measured along the X-axis (roll), Y-axis (pitch), and Z-axis (yaw). Motions and displacements of the capsules that occurred after contact were determined from high-speed motion pictures. The theoretical investigation was conducted to determine the accelerations that might occur along the X-axis when the capsule contacted the water from a 90 deg flight path at a 0 deg attitude. Assuming a rigid body, computations were made from equations obtained by utilizing the principle of the conservation of momentum. The agreement among data obtained from the model test, the full-scale test, and the theory was very good. The accelerations along the X-axis, for a vertical flight path and 0 deg attitude, were in the order of 40g. For a 65 deg flight path and 0 deg attitude, the accelerations along the X-axis were in the order of 50g. Changes in contact attitude, in either the positive or negative direction from 0 deg attitude, considerably reduced the magnitude of the accelerations measured along the X-axis. Accelerations measured along the Y- and Z-axes were relatively small at all test conditions.

  4. Water-Landing Characteristics of a Reentry Capsule

    NASA Technical Reports Server (NTRS)

    McGehee, John R.; Hathaway, Melvin E.; Vaughan, Victor L., Jr.

    1959-01-01

    Experimental and theoretical investigations have been made to determine the water-landing characteristics of a conical-shaped reentry capsule having a segment of a sphere as the bottom. For the experimental portion of the investigation, a 1/12-scale model capsule and a full-scale capsule were tested for nominal flight paths of 65 deg and 90 deg (vertical), a range of contact attitudes from -30 deg to 30 deg, and a full-scale vertical velocity of 30 feet per second at contact. Accelerations were measured by accelerometers installed at the centers of gravity of the model and full-scale capsules. For the model test the accelerations were measured along the X-axis (roll) and Z-axis (yaw) and for the full-scale test they were measured along the X-axis (roll), Y-axis (pitch), and Z-axis (yaw). Motions and displacements of the capsules that occurred after contact were determined from high-speed motion pictures. The theoretical investigation was conducted to determine the accelerations that might occur along the X-axis when the capsule contacted the water from a 90 deg flight path at a 0 deg attitude. Assuming a rigid body, computations were made from equations obtained by utilizing the principle of the conservation of momentum. The agreement among data obtained from the model test, the full-scale test, and the theory was very good. The accelerations along the X-axis, for a vertical flight path and 0 deg attitude, were in the order of 40g. For a 65 deg flight path and 0 deg attitude, the accelerations along the X-axis were in the order of 50g. Changes in contact attitude, in either the positive or negative direction from 0 deg attitude, considerably reduced the magnitude of the accelerations measured along the X-axis. Accelerations measured along the Y- and Z-axes were relatively small at all test conditions.

  5. A practical scale for Multi-Faceted Organizational Health Climate Assessment.

    PubMed

    Zweber, Zandra M; Henning, Robert A; Magley, Vicki J

    2016-04-01

    The current study sought to develop a practical scale to measure 3 facets of workplace health climate from the employee perspective as an important component of a healthy organization. The goal was to create a short, usable yet comprehensive scale that organizations and occupational health professionals could use to determine if workplace health interventions were needed. The proposed Multi-faceted Organizational Health Climate Assessment (MOHCA) scale assesses facets that correspond to 3 organizational levels: (a) workgroup, (b) supervisor, and (c) organization. Ten items were developed and tested on 2 distinct samples, 1 cross-organization and 1 within-organization. Exploratory and confirmatory factor analyses yielded a 9-item, hierarchical 3-factor structure. Tests confirmed MOHCA has convergent validity with related constructs, such as perceived organizational support and supervisor support, as well as discriminant validity with safety climate. Lastly, criterion-related validity was found between MOHCA and health-related outcomes. The multi-faceted nature of MOHCA provides a scale that has face validity and can be easily translated into practice, offering a means for diagnosing the shortcomings of an organization or workgroup's health climate to better plan health and well-being interventions. (c) 2016 APA, all rights reserved).

  6. The effect of glicerol and sorbitol plasticizers toward disintegration time of phyto-capsules

    NASA Astrophysics Data System (ADS)

    Pudjiastuti, Pratiwi; Hendradi, Esti; Wafiroh, Siti; Harsini, Muji; Darmokoesoemo, Handoko

    2016-03-01

    The aim of research is determining the effect of glycerol and sorbitol toward the disintegration time of phyto-capsules, originated capsules from plant polysaccharides. Phyto-capsules were made from polysaccharides and 0.5% (v/v) of glycerol and sorbitol of each. The seven capsules of each were determined the disintegration time using Erweka disintegrator. The mean of disintegration time of phyto-capsules without plasticizers, with glycerol and sorbitol were 25'30"; 45'15" and 35'30" respectively. The color and colorless gelatin capsules showed the mean of disintegration time 7'30" and 2'35" respectively.

  7. On the convergence between PSY-5 domains and PID-5 domains and facets: implications for assessment of DSM-5 personality traits.

    PubMed

    Anderson, Jaime L; Sellbom, Martin; Bagby, R Michael; Quilty, Lena C; Veltri, Carlo O C; Markon, Kristian E; Krueger, Robert F

    2013-06-01

    The DSM-5 Personality and Personality Disorders workgroup and their consultants have developed the 220-item, self-report Personality Inventory for the DSM-5 (PID-5) for direct assessment of the proposed personality trait system for DSM-5; however, most practicing clinical psychologists will likely continue to rely on separate omnibus measures to index symptoms and traits associated with psychopathology. The Minnesota Multiphasic Personality Inventory-2 Restructured Form (MMPI-2-RF) is one such measure and assesses the Personality Psychopathology Five (PSY-5) domains, which are conceptual cognates of the DSM-5 trait domains. The current study examined the associations between the MMPI-2-RF PSY-5 scales and the DSM-5 trait domains and facets indexed by the PID-5. A clear pattern of convergence was found indicating that each of the PSY-5 scales was most highly correlated with its conceptually expected PID-5 counterpart (rs = .44-.67; Mdn r = .53) and facet correlations generally showed the same pattern. Similarly, when each of the PSY-5 scales was regressed onto the PID-5 domains, the conceptually expected pattern of associations emerged even more clearly. Finally, a joint exploratory factor analysis with the PSY-5 and PID-5 trait facet scales indicated a five-factor solution that clearly resembled both of the PSY-5/DSM-5 trait domains. These results show clear evidence that the MMPI-2-RF has utility in the assessment of dimensional personality traits proposed for the upcoming DSM-5.

  8. Capsule Endoscopy in the Assessment of Obscure Gastrointestinal Bleeding: An Economic Analysis

    PubMed Central

    Palimaka, S; Blackhouse, Gord; Goeree, Ron

    2015-01-01

    Background Small-bowel capsule endoscopy is a tool used to visualize the small bowel to identify the location of bleeds in obscure gastrointestinal bleeding (OGIB). Capsule endoscopy is currently funded in Ontario in cases where there has been a failure to identify a source of bleeding via conventional diagnostic procedures. In Ontario, capsule endoscopy is a diagnostic option for patients whose findings on esophagogastroduodenoscopy, colonoscopy, and push enteroscopy have been negative (i.e., the source of bleeding was not found). Objectives This economic analysis aims to estimate the budget impact of different rates of capsule endoscopy use as a complement to push enteroscopy procedures in patients aged 18 years and older. Data Sources Population-based administrative databases for Ontario were used to identify patients receiving push enteroscopy and small-bowel capsule endoscopy in the fiscal years 2008 to 2012. Review Methods A systematic literature search was performed to identify economic evaluations of capsule endoscopy for the investigation of OGIB. Studies were assessed for their methodological quality and their applicability to the Ontarian setting. An original budget impact analysis was performed using data from Ontarian administrative sources and published literature. The budget impact was estimated for different levels of use of capsule endoscopy as a complement to push enteroscopy due to the uncertain clinical utility of the capsule based on current clinical evidence. The analysis was conducted from the provincial public payer perspective. Results With varying rates of capsule endoscopy use, the budgetary impact spans from savings of $510,000,1 when no (0%) push enteroscopy procedures are complemented with capsule endoscopy, to $2,036,000, when all (100%) push enteroscopy procedures are complemented with capsule endoscopy. A scenario where 50% of push enteroscopy procedures are complemented with capsule endoscopy (expected use based on expert opinion

  9. Alginate/sodium caseinate aqueous-core capsules: a pH-responsive matrix.

    PubMed

    Ben Messaoud, Ghazi; Sánchez-González, Laura; Jacquot, Adrien; Probst, Laurent; Desobry, Stéphane

    2015-02-15

    Alginate capsules have several applications. Their functionality depends considerably on their permeability, chemical and mechanical stability. Consequently, the creation of composite system by addition of further components is expected to control mechanical and release properties of alginate capsules. Alginate and alginate-sodium caseinate composite liquid-core capsules were prepared by a simple extrusion. The influence of the preparation pH and sodium caseinate concentration on capsules physico-chemical properties was investigated. Results showed that sodium caseinate influenced significantly capsules properties. As regards to the membrane mechanical stability, composite capsules prepared at pH below the isoelectric point of sodium caseinate exhibited the highest surface Young's modulus, increasing with protein content, explained by potential electrostatic interactions between sodium caseinate amino-groups and alginate carboxylic group. The kinetic of cochineal red A release changed significantly for composite capsules and showed a pH-responsive release. Sodium caseinate-dye mixture studied by absorbance and fluorescence spectroscopy confirmed complex formation at pH 2 by electrostatic interactions between sodium caseinate tryptophan residues and cochineal red sulfonate-groups. Consequently, the release mechanism was explained by membrane adsorption process. This global approach is useful to control release mechanism from macro and micro-capsules by incorporating guest molecules which can interact with the entrapped molecule under specific conditions. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. Magnesium Ion Acts as a Signal for Capsule Induction in Cryptococcus neoformans.

    PubMed

    Rathore, Sudarshan S; Raman, Thiagarajan; Ramakrishnan, Jayapradha

    2016-01-01

    Cryptococcal meningitis caused by Cryptococcus neoformans, is a common opportunistic neural infection in immunocompromised individuals. Cryptococcus meningitis is associated with fungal burden with larger capsule size in cerebrospinal fluid (CSF). To understand the role of CSF constituents in capsule enlargement, we have evaluated the effect of artificial CSF on capsule induction in comparison with various other capsule inducing media. Two different strains of C. neoformans, an environmental and a clinical isolates were used in the present study. While comparing the various capsule inducing media for the two different strains of C. neoformans, it was observed that the capsule growth was significantly increased when grown in artificial CSF at pH 5.5, temperature 34°C for ATCC C. neoformans and 37°C for Clinical C. neoformans and with an incubation period of 72 h. In addition, artificial CSF supports biofilm formation in C. neoformans. While investigating the individual components of artificial CSF, we found that Mg(2+) ions influence the capsule growth in both environmental and clinical strains of C. neoformans. To confirm our results we studied the expression of four major CAP genes namely, CAP10, CAP59, CAP60, and CAP64 in various capsule inducing media and in different concentrations of Mg(2+) and Ca(2+). Our results on gene expression suggest that, Mg(2+) does have an effect on CAP gene expression, which are important for capsule biosynthesis and virulence. Our findings on the role of Mg(2+) ion as a signal for capsule induction will promote a way to elucidate the control mechanisms for capsule biosynthesis in C. neoformans.

  11. Magnesium Ion Acts as a Signal for Capsule Induction in Cryptococcus neoformans

    PubMed Central

    Rathore, Sudarshan S.; Raman, Thiagarajan; Ramakrishnan, Jayapradha

    2016-01-01

    Cryptococcal meningitis caused by Cryptococcus neoformans, is a common opportunistic neural infection in immunocompromised individuals. Cryptococcus meningitis is associated with fungal burden with larger capsule size in cerebrospinal fluid (CSF). To understand the role of CSF constituents in capsule enlargement, we have evaluated the effect of artificial CSF on capsule induction in comparison with various other capsule inducing media. Two different strains of C. neoformans, an environmental and a clinical isolates were used in the present study. While comparing the various capsule inducing media for the two different strains of C. neoformans, it was observed that the capsule growth was significantly increased when grown in artificial CSF at pH 5.5, temperature 34°C for ATCC C. neoformans and 37°C for Clinical C. neoformans and with an incubation period of 72 h. In addition, artificial CSF supports biofilm formation in C. neoformans. While investigating the individual components of artificial CSF, we found that Mg2+ ions influence the capsule growth in both environmental and clinical strains of C. neoformans. To confirm our results we studied the expression of four major CAP genes namely, CAP10, CAP59, CAP60, and CAP64 in various capsule inducing media and in different concentrations of Mg2+ and Ca2+. Our results on gene expression suggest that, Mg2+ does have an effect on CAP gene expression, which are important for capsule biosynthesis and virulence. Our findings on the role of Mg2+ ion as a signal for capsule induction will promote a way to elucidate the control mechanisms for capsule biosynthesis in C. neoformans. PMID:27014245

  12. Analysis of lomustine drug content in FDA-approved and compounded lomustine capsules.

    PubMed

    KuKanich, Butch; Warner, Matt; Hahn, Kevin

    2017-02-01

    OBJECTIVE To determine the lomustine content (potency) in compounded and FDA-approved lomustine capsules. DESIGN Evaluation study. SAMPLE 2 formulations of lomustine capsules (low dose [7 to 11 mg] and high dose [40 to 48 mg]; 5 capsules/dose/source) from 3 compounders and from 1 manufacturer of FDA-approved capsules. PROCEDURES Lomustine content was measured by use of a validated high-pressure liquid chromatography method. An a priori acceptable range of 90% to 110% of the stated lomustine content was selected on the basis of US Pharmacopeia guidelines. RESULTS The measured amount of lomustine in all compounded capsules was less than the stated content (range, 59% to 95%) and was frequently outside the acceptable range (failure rate, 2/5 to 5/5). Coefficients of variation for lomustine content ranged from 4.1% to 16.7% for compounded low-dose capsules and from 1.1% to 10.8% for compounded high-dose capsules. The measured amount of lomustine in all FDA-approved capsules was slightly above the stated content (range, 104% to 110%) and consistently within the acceptable range. Coefficients of variation for lomustine content were 0.5% for low-dose and 2.3% for high-dose FDA-approved capsules. CONCLUSIONS AND CLINICAL RELEVANCE Compounded lomustine frequently did not contain the stated content of active drug and had a wider range of lomustine content variability than did the FDA-approved product. The sample size was small, and larger studies are needed to confirm these findings; however, we recommend that compounded veterinary formulations of lomustine not be used when appropriate doses can be achieved with FDA-approved capsules or combinations of FDA-approved capsules.

  13. Capsule endoscopy: in search of the ideal image.

    PubMed

    Enns, Robert

    2008-01-01

    Capsule studies can be reviewed by varying rates and speeds; however, the presence of significant debris is frustrating to the reviewer much like the excessive stool that tends to hinder the progress of a colonoscopist. Numerous studies have been published in regards to the advantages of an ideal preparation in the setting of capsule endoscopy. This most recent study by Wei et al. is another study that has demonstrated that a colonic preparation, in this situation, combined with simethicone given just prior to the capsule study results in improved visibility of the mucosa. In theory, this will lead to an improved diagnostic ability to limit excessive reading duration.

  14. Multilayered sandwich-like architecture containing large-scale faceted Al–Cu–Fe quasicrystal grains

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wei, Dongxia; He, Zhanbing, E-mail: hezhanbing@ustb.edu.cn

    Faceted quasicrystals are structurally special compared with traditional crystals. Although the application of faceted quasicrystals has been expected, wide-scale application has not occurred owing to the limited exposure of the facets. Using a facile method of heat treatment, we synthesize a multilayered sandwich-like structure with each layer composed of large-scale pentagonal-dodecahedra of Al–Cu–Fe quasicrystals. Moreover, there are channels between the adjacent Al–Cu–Fe layers that serve to increase the exposure of the facets of quasicrystals. Scanning electron microscopy, transmission electron microscopy, and X-ray diffraction are used to characterize the multilayered architecture, and the generation mechanisms of this special structure are alsomore » discussed. - Highlights: • A multilayered sandwich-like structure is produced by a facile method. • Each layer is covered by large-scale faceted Al–Cu–Fe quasicrystals. • There are channels between the adjacent Al–Cu–Fe layers.« less

  15. Limited distal clavicle excision of acromioclavicular joint osteoarthritis.

    PubMed

    Gokkus, K; Saylik, M; Atmaca, H; Sagtas, E; Aydin, A T

    2016-05-01

    Resection of the distal aspect of clavicle has a well-documented treatment modality in case of acromioclavicular joint osteoarthritis resistant to conservative treatment. Limited (mean ∼0.5cm distal end of clavicle resection) distal clavicle excision of A-C joint arthritis in cases resistant to conservative treatment may reduce the pain and improve the shoulder function. In this study, we retrospectively evaluated the results of limited distal clavicle excision of acromioclavicular joint osteoarthritis resistant to conservative treatment. All patients were evaluated by using the Visual Analogue Scale (VAS) and UCLA shoulder rating scale (University of California Los Angeles), either before surgery or final follow-up period for pain and functional results, respectively. A total of 110 patients (48 male, 62 female) with AC joint arthritis, treated between the years of 2008-2012, were retrospectively analyzed. A total of 30 patients (12 male, 18 female) who failed to show improvement with conservative treatment underwent limited surgical open excision of distal clavicle. The mean age of the study population was 52.5±1.2 years. The mean follow-up period was 27±1.3 months. The mean preoperative VAS score was 83.6±5.58 (range, 70-90) while mean VAS was 26.6±9.3 (range, 10-50) at the final follow-up. There was a statistically significant difference between pre- and postoperative VAS scores in patients who had treated by surgical approach (P<0.001). The mean UCLA score of the patients increased postoperatively from 11.5 (range, 9-14) to 29.2 (range, 27-32) at the final follow-up. There was a statistically significant difference between the two time periods with respect to UCLA scores (P<0.001). In patients with AC osteoarthritis resistant to conservative therapy, the hypothesized limited clavicle excision (mean ∼0.5cm distal end of clavicle resection with preserving coracoclavicular ligaments and inferior capsule) reduced the pain and improved the shoulder function

  16. The Antiphagocytic Activity of SeM of Streptococcus equi Requires Capsule.

    PubMed

    Timoney, John F; Suther, Pranav; Velineni, Sridhar; Artiushin, Sergey C

    2014-01-01

    Resistance to phagocytosis is a crucial virulence property of Streptococcus equi (Streptococcus equi subsp. equi; Se), the cause of equine strangles. The contribution and interdependence of capsule and SeM to killing in equine blood and neutrophils were investigated in naturally occurring strains of Se. Strains CF32, SF463 were capsule and SeM positive, strains Lex90, Lex93 were capsule negative and SeM positive and strains Se19, Se1-8 were capsule positive and SeM deficient. Phagocytosis and killing of Se19, Se1-8, Lex90 and Lex93 in equine blood and by neutrophils suspended in serum were significantly (P ≤ 0.02) greater compared to CF32 and SF463. The results indicate capsule and SeM are both required for resistance to phagocytosis and killing and that the anti-phagocytic property of SeM is greatly reduced in the absence of capsule.

  17. Ultrasonic technique for inspection of GPHS capsule girth weld integrity

    NASA Astrophysics Data System (ADS)

    Placr, Arnost

    1993-05-01

    An innovative nondestructive examination (NDE) technique for the inspection of integrity of General Purpose Heat Source (GPHS) capsule girth welds was developed employing a Lamb wave as the mode of the sound propagation. Reliability of the Lamb wave technique was tested on GPHS capsules using plutonium pallet simulators. All ten capsules, which were previously rejected, passed ultrasonic (UT) inspection using the Lamb wave technique.

  18. Cross-cultural evidence for the two-facet structure of pride.

    PubMed

    Shi, Yan; Chung, Joanne M; Cheng, Joey T; Tracy, Jessica L; Robins, Richard W; Chen, Xiao; Zheng, Yong

    2015-04-01

    Across six studies conducted in Mainland China and South Korea, the present research extended prior findings showing that pride is comprised of two distinct conceptual and experiential facets in the U.S.: a pro-social, achievement-oriented "authentic pride", and an arrogant, self-aggrandizing "hubristic pride". This same two-facet structure emerged in Chinese participants' semantic conceptualizations of pride (Study 1), Chinese and Koreans' dispositional tendencies to experience pride (Studies 2, 3a, and 3b), Chinese and Koreans' momentary pride experiences (Studies 3a, 3b, and 5), and Americans' pride experiences using descriptors derived indigenously in Korea (Study 4). Together, these studies provide the first evidence that the two-facet structure of pride generalizes to cultures with highly divergent views of pride and self-enhancement processes from North America.

  19. Cross-cultural evidence for the two-facet structure of pride

    PubMed Central

    Shi, Yan; Chung, Joanne M.; Cheng, Joey T.; Tracy, Jessica L.; Robins, Richard W.; Chen, Xiao; Zheng, Yong

    2016-01-01

    Across six studies conducted in Mainland China and South Korea, the present research extended prior findings showing that pride is comprised of two distinct conceptual and experiential facets in the U.S.: a pro-social, achievement-oriented “authentic pride”, and an arrogant, self-aggrandizing “hubristic pride”. This same two-facet structure emerged in Chinese participants’ semantic conceptualizations of pride (Study 1), Chinese and Koreans’ dispositional tendencies to experience pride (Studies 2, 3a, and 3b), Chinese and Koreans’ momentary pride experiences (Studies 3a, 3b, and 5), and Americans’ pride experiences using descriptors derived indigenously in Korea (Study 4). Together, these studies provide the first evidence that the two-facet structure of pride generalizes to cultures with highly divergent views of pride and self-enhancement processes from North America. PMID:27158171

  20. The history of time for capsule endoscopy.

    PubMed

    Adler, Samuel N

    2017-05-01

    Capsule endoscopy was conceived by inventive minds of good people. In the beginning there was a will to do something for medicine. The idea fomented after a discourse between the talented engineer with his physician friend. It took years to develop the concept. Then excellent engineers created de novo the necessary components to turn the capsule into a viable reality. The story is a tribute to human ingenuity.

  1. Solid State Stability of Extemporaneously Prepared Levothyroxine Aliquots and Capsules.

    PubMed

    Fortner, Jeff; Salton, Jason; Carlson, Christie; Wheeler, Rich; Cote, Brianna; Rao, Deepa

    2015-01-01

    The purpose of this research was to collect, analyze, and compare stability data for levothyroxine (T4) powder in the anhydrous and pentahydrate form when prepared as an aliquot and in capsules. Two different compounding pharmacies, Central Iowa Compounding and Gateway Medical Pharmacy, used different forms of T4 and aliquot formulations, which were studied to determine the beyond-use date at ±5% or ±10% of labeled strength. T4 was extracted from aliquot and capsule formulations and assessed using reverse-phase high- performance liquid chromatography validated to differentiate between the degraded and original forms of T4. The results indicate that T4 1:100 aliquot formulation prepared with silica gel or Avicel as filler are stable for 120 days at ±10% labeled potency, but at ±5% labeled potency, the silica gel and Avicel aliquot formulations are stable for 45 and 30 days, respectively. The silica gel capsules prepared from fresh aliquot were stable for 120 days at ±10% labeled potency and 90 days at ±5% labeled potency, while the Avicel capsules prepared from fresh aliquot were stable for 180 days at both ±10% and ±5% labeled potency. Avicel capsules prepared from old aliquot (120 days) and fresh aliquot (1 day) were also compared for stability. The old aliquot Avicel capsules were stable for 14 days at ±5% labeled potency and 150 days at ±10% labeled potency, while new aliquot Avicel capsules were stable for 180 days at both ±10% and ±5% labeled potency. Based on our data, there can be significant variation in the beyond-use dates assigned to T4 capsules based on the diluents used for aliquots, the final capsule formulations, and the potency standards applied. These results also indicate that pharmacists must exercise caution when using older aliquots and may have to assign shorter beyond-use dates.

  2. Safety of capsule endoscopy using human body communication in patients with cardiac devices.

    PubMed

    Chung, Joo Won; Hwang, Hye Jin; Chung, Moon Jae; Park, Jeong Youp; Pak, Hui-Nam; Song, Si Young

    2012-06-01

    The MiroCam (IntroMedic, Ltd., Seoul, Korea) is a small-bowel capsule endoscope that uses human body communication to transmit data. The potential interactions between cardiac devices and the capsule endoscope are causes for concern, but no data are available for this matter. This clinical study was designed to evaluate the potential influence of the MiroCam capsules on cardiac devices. Patients with cardiac pacemakers or implantable cardiac defibrillators referred for evaluation of small bowel disease were prospectively enrolled in this study. Before capsule endoscopy, a cardiologist checked baseline electrocardiograms and functions of the cardiac devices. Cardiac rhythms were continuously monitored by 24-h telemetry during capsule endoscopy in the hospital. After completion of procedures, functions of the cardiac devices were checked again for interference. Images from the capsule endoscopy were reviewed and analyzed for technical problems. Six patients, three with pacemakers and three with implantable cardiac defibrillators, were included in the study. We identified no disturbances in the cardiac devices and no arrhythmias detected on telemetry monitoring during capsule endoscopy. No significant changes in the programmed parameters of the cardiac devices were noted after capsule endoscopy. There were no imaging disturbances from the cardiac devices on capsule endoscopy. Capsule endoscopy using human body communication to transmit data was safely performed in patients with cardiac pacemakers or implantable cardiac defibrillators. Images from the capsule endoscopy were not affected by cardiac devices. A further large-scale study is required to confirm the safety of capsule endoscopy with various types of cardiac devices.

  3. Rotational injury of cervical facets: CT analysis of fracture patterns with implications for management and neurologic outcome.

    PubMed

    Shanmuganathan, K; Mirvis, S E; Levine, A M

    1994-11-01

    Imaging studies of patients with rotational facet injuries of the cervical spine were retrospectively reviewed to determine the prevalence and pattern of associated fractures, to correlate injury pattern with recommended surgical stabilization, and to assess neurologic outcome. Radiographs and CT scans obtained for 40 consecutive patients with rotational facet injuries of the cervical spine during a 70-month period were retrospectively reviewed to determine injury level, presence, and orientation of facet fractures, and concurrent nonfacet injuries. Imaging findings were reviewed to assess the likelihood of instability and to determine the most appropriate stabilization requirement. Medical records were reviewed to ascertain mechanism of injury, initial neurologic deficit, and surgical findings. Among the 40 patients with cervical rotational facet injuries, 11 (27%) had pure unilateral facet dislocation or subluxation without associated fractures, and 29 (73%) had concurrent facet fractures involving the inferior facet of the rotated vertebra (n = 13), the superior facet of the subjacent vertebra (n = 9), or both (n = 7). Injury of the rotated vertebra was unilateral in 22 patients but bilateral in 18 patients. Facet fractures frequently extended into the ipsilateral lamina or articular pillar or both. An avulsion fracture from the posteroinferior aspect of the rotated vertebral body, indicating disk disruption, occurred in 10 patients (25%), and seven patients (17%) had complete isolation of an articular pillar. Facet fractures were confirmed for 27 patients who underwent surgical stabilization. Neurologic deficits developed in 29 (73%) of the 40 patients and included radiculopathy in 11 patients and cord syndromes in 18 patients. Pure dislocation without a facet fracture was more likely to lead to a cord syndrome (p = .006). Cervical rotational facet injuries are often accompanied by facet fractures and bilateral damage of the rotated vertebra. These injuries

  4. Nitrogen Source-Dependent Capsule Induction in Human-Pathogenic Cryptococcus Species

    PubMed Central

    Frazzitta, Aubrey E.; Vora, Haily; Price, Michael S.; Tenor, Jennifer L.; Betancourt-Quiroz, Marisol; Toffaletti, Dena L.; Cheng, Nan

    2013-01-01

    Cryptococcus neoformans and C. gattii cause meningoencephalitis and are an increasing human health threat. These pathogenic Cryptococcus species are neurotropic and persist in the cerebrospinal fluid (CSF) of the mammalian host during infection. In order to survive in the host, pathogenic fungi must procure nutrients, such as carbon and nitrogen, from the CSF. To enhance our understanding of nutrient acquisition during central nervous system infection by Cryptococcus species, we examined the utilization of nitrogen sources available in CSF. We screened for the growth and capsule production of 817 global environmental and clinical isolates on various sources of nitrogen. Both environmental and clinical strains grew robustly on uric acid, Casamino Acids, creatinine, and asparagine as sole nitrogen sources. Urea induced the greatest magnitude of capsule induction. This induction was greater in Cryptococcus gattii than in C. neoformans. We confirmed the ability of nonpreferred nitrogen sources to increase capsule production in pathogenic species of Cryptococcus. Since urea is metabolized to ammonia and CO2 (a known signal for capsule induction), we examined urea metabolism mutants for their transcriptional response to urea regarding capsule production. The transcriptional profile of C. neoformans under urea-supplemented conditions revealed both similar and unique responses to other capsule-inducing conditions, including both intra- and extracellular urea utilization. As one of the most abundant nitrogen sources in the CSF, the ability of Cryptococcus to import urea and induce capsule production may substantially aid this yeast's survival and propagation in the host. PMID:23975889

  5. Nitrogen source-dependent capsule induction in human-pathogenic cryptococcus species.

    PubMed

    Frazzitta, Aubrey E; Vora, Haily; Price, Michael S; Tenor, Jennifer L; Betancourt-Quiroz, Marisol; Toffaletti, Dena L; Cheng, Nan; Perfect, John R

    2013-11-01

    Cryptococcus neoformans and C. gattii cause meningoencephalitis and are an increasing human health threat. These pathogenic Cryptococcus species are neurotropic and persist in the cerebrospinal fluid (CSF) of the mammalian host during infection. In order to survive in the host, pathogenic fungi must procure nutrients, such as carbon and nitrogen, from the CSF. To enhance our understanding of nutrient acquisition during central nervous system infection by Cryptococcus species, we examined the utilization of nitrogen sources available in CSF. We screened for the growth and capsule production of 817 global environmental and clinical isolates on various sources of nitrogen. Both environmental and clinical strains grew robustly on uric acid, Casamino Acids, creatinine, and asparagine as sole nitrogen sources. Urea induced the greatest magnitude of capsule induction. This induction was greater in Cryptococcus gattii than in C. neoformans. We confirmed the ability of nonpreferred nitrogen sources to increase capsule production in pathogenic species of Cryptococcus. Since urea is metabolized to ammonia and CO(2) (a known signal for capsule induction), we examined urea metabolism mutants for their transcriptional response to urea regarding capsule production. The transcriptional profile of C. neoformans under urea-supplemented conditions revealed both similar and unique responses to other capsule-inducing conditions, including both intra- and extracellular urea utilization. As one of the most abundant nitrogen sources in the CSF, the ability of Cryptococcus to import urea and induce capsule production may substantially aid this yeast's survival and propagation in the host.

  6. A biodegradable, immunoprotective, dual nanoporous capsule for cell-based therapies.

    PubMed

    Zhang, Xulang; He, Hongyan; Yen, Chi; Ho, Wiston; Lee, L James

    2008-11-01

    To demonstrate the transplantation of drug-secreting cells with immunoprotection, a biodegradable delivery device combining two nanoporous capsules is developed using secretory alkaline phosphatase gene (SEAP) transfected mouse embryonic stem (mES) cells as a model system. The outer capsule is a poly (ethylene glycol) (PEG)-coated poly (epsilon-caprolactone) (PCL) chamber covered with a PEG grafted PCL nanoporous membrane made by phase inversion technique. SEAP gene transfected mES cells encapsulated in alginate-poly-L-lysine (AP) microcapsules are placed in the PCL capsule. Both nanoporous capsules showed good immunoprotection in the IgG solution. In microcapsules, mES cells could form a spheroid embryonic body (EB) and grow close to the microcapsule size. The secreted SEAP from encapsulated mES cells increased gradually to a maximum value before reaching a steady level, following the cell growth pattern in the microcapsule. Without microcapsules, mES cells only formed a monolayer in the large PCL capsule. The secreted SEAP release was very low. The integrated device showed a similar cell growth pattern to that in microcapsules alone, while the SEAP release rate could be regulated by the pore size of the large capsule. This integrated device can achieve multi-functionalities for cell-based therapy, i.e. a 3-D microenvironment provided by microcapsules for cell growth, superior immunoprotection and controllable release performance provided by the two nanoporous membranes, and good fibrosis prevention by PEG surface modification of the large capsule.

  7. Capsule- and disk-filter procedure

    USGS Publications Warehouse

    Skrobialowski, Stanley C.

    2016-01-01

    Capsule and disk filters are disposable, self-contained units composed of a pleated or woven filter medium encased in a polypropylene or other plastic housing that can be connected inline to a sample-delivery system (such as a submersible or peristaltic pump) that generates sufficient pressure (positive or negative) to force water through the filter. Filter media are available in several pore sizes, but 0.45 µm is the pore size used routinely for most studies at this time. Capsule or disk filters (table 5.2.1.A.1) are required routinely for most studies when filtering samples for trace-element analyses and are recommended when filtering samples for major-ion or other inorganic-constituent analyses.

  8. Capsule endoscopy in the diagnosis of Crohn’s disease

    PubMed Central

    Niv, Yaron

    2013-01-01

    Crohn’s disease is a chronic inflammatory disorder affecting any part of the gastrointestinal tract, but frequently involves the small and large bowel. Typical presenting symptoms include abdominal pain and diarrhea. Patients with this disorder may also have extraintestinal manifestations, including arthritis, uveitis, and skin lesions. The PillCam™SB capsule is an ingestible disposable video camera that transmits high quality images of the small intestinal mucosa. This enables the small intestine to be readily accessible to physicians investigating for the presence of small bowel disorders, such as Crohn’s disease. Four meta-analyses have demonstrated that capsule endoscopy identifies Crohn’s disease when other methods are not helpful. It should be noted that it is the best noninvasive procedure for assessing mucosal status, but is not superior to ileocolonoscopy, which remains the gold standard for assessment of ileocolonic disease. Mucosal healing along the small bowel can only be demonstrated by an endoscopic procedure such as capsule endoscopy. Achievement of long-term mucosal healing has been associated with a trend towards a decreased need for hospitalization and a decreased requirement for corticosteroid treatment in patients with Crohn’s disease. Recently, we have developed and validated the Capsule Endoscopy Crohn’s Disease Activity Index (also known as the Niv score) for Crohn’s disease of the small bowel. The next step is to expand our score to the colon, and to determine the role and benefit of a capsule endoscopy activity score in patients suffering from Crohn’s ileocolitis and/or colitis. This scoring system will also serve to improve our understanding of the impact of capsule endoscopy, and therefore treatment, on the immediate outcome of this disorder. As the best procedure available for assessing mucosal status, capsule endoscopy will provide important information about the course and outcome of Crohn’s disease. PMID:23818810

  9. Mercury Capsule Retrorocket Test in the Altitude Wind Tunnel

    NASA Image and Video Library

    1960-09-21

    A mechanic at the National Aeronautics and Space Administration (NASA) Lewis Research Center prepares the inverted base of a Mercury capsule for a test of its posigrade retrorockets inside the Altitude Wind Tunnel. In October 1959 NASA’s Space Task Group allocated several Project Mercury assignments to Lewis. The Altitude Wind Tunnel was modified to test the Atlas separation system, study the escape tower rocket plume, train astronauts to bring a spinning capsule under control, and calibrate the capsule’s retrorockets. The turning vanes, makeup air pipes, and cooling coils were removed from the wide western end of the tunnel to create a 51-foot diameter test chamber. The Mercury capsule had a six-rocket retro-package affixed to the bottom of the capsule. Three of these were posigrade rockets used to separate the capsule from the booster and three were retrograde rockets used to slow the capsule for reentry into the earth’s atmosphere. Performance of the retrorockets was vital since there was no backup system. Qualification tests of the retrorockets began in April 1960 on a retrograde thrust stand inside the southwest corner of the Altitude Wind Tunnel. These studies showed that a previous issue concerning the delayed ignition of the propellant had been resolved. Follow-up test runs verified reliability of the igniter’s attachment to the propellant. In addition, the capsule’s retrorockets were calibrated so they would not alter the capsule’s attitude when fired.

  10. Mercury Capsule Construction at the NASA Lewis Research Center

    NASA Image and Video Library

    1959-08-21

    A NASA mechanic secures the afterbody to a Mercury capsule in the hangar at the Lewis Research Center. The capsule was one of two built at Lewis for the “Big Joe” launches scheduled for September 1959. The initial phase of Project Mercury consisted of a series of unmanned launches using the Air Force’s Redstone and Atlas boosters and the Langley-designed Little Joe boosters. The first Atlas launch, referred to as “Big Joe”, was a single attempt early in Project Mercury to use a full-scale Atlas booster to simulate the reentry of a mock-up Mercury capsule without actually placing it in orbit. The overall design of Big Joe had been completed by December 1958, and soon thereafter project manager Aleck Bond assigned NASA Lewis the task of designing the electronic instrumentation and automatic stabilization system. Lewis also constructed the capsule’s lower section, which contained a pressurized area with the electronics and two nitrogen tanks for the retrorockets. Lewis technicians were responsible for assembling the entire capsule: the General Electric heatshield, NASA Langley afterbody and recovery canister, and Lewis electronics and control systems. On June 9, 1959, the capsule was loaded on an air force transport aircraft and flown to Cape Canaveral. A team of 45 test operations personnel from Lewis followed the capsule to Florida and spent the ensuing months preparing it for launch. The launch took place in the early morning hours of September 9, 1959.

  11. Nifedipine capsules may provide a viable alternative to oral powders for paediatric patients.

    PubMed

    Helin-Tanninen, M; Naaranlahti, T; Kontra, K; Savolainen, K

    2007-02-01

    To compare content uniformities between different sizes of extemporaneously compounded nifedipine oral powders and capsules, in order to find out if capsules could be used instead of oral powders as paediatric medications. Actual content and content uniformity of extemporaneously compounded 1-mg nifedipine oral powders and capsules were evaluated by a high performance liquid chromatographic assay. Capsules and powders were prepared by triturating 10-mg nifedipine tablets with different amounts of lactose or microcrystalline cellulose with a mortar and pestle using a standard geometric dilution technique. Oral powders were weighed individually and capsules were filled by a hand-operated capsule-filling machine. Four different sizes of powders (500, 300, 100 and 50 mg) and three different sizes of capsules (numbers 1, 3 and 4) were prepared. Ten oral powders and 10 capsules from each batch were randomly selected and individually assayed for nifedipine amount. The extemporaneously prepared nifedipine oral powders and capsules were within acceptable limits for content uniformity, as defined by the European Pharmacopoeia, but the results indicate that the loss of nifedipine during the preparation process may be considerable for both preparations. The concentration on nifedipine decreased while the total mass of the oral powder decreased. These results demonstrate that nifedipine oral powders can be replaced by capsules, whose contents are emptied for use, in paediatric medications. Compounding small capsules, such as size number 3 or 4, is acceptable when considering the average drug content. The total weight of the oral powder should be at least 300 mg. The preparation of nifedipine in all studied capsule sizes was safe with either lactose monohydrate or microcrystalline cellulose as excipients. Thus, emptied capsules seem to be a good choice for delivering a paediatric medication. The loss of nifedipine was considerable in oral powders with low total weight.

  12. Kinetic simulation of hydrodynamic equivalent capsule implosions

    NASA Astrophysics Data System (ADS)

    Kwan, Thomas; Le, Ari; Schmitt, Mark; Herrmann, Hans

    2016-10-01

    We have carried out simulations of direct-drive hydrodynamic equivalent capsule implosion experiments conducted on Omega laser facility at the Laboratory of Laser Energetics of the University of Rochester. The capsules had a glass shell (SiO2) 4.87 μm with an inner diameter of 1086 μm. One was filled with deuterium (D) and tritium (T) at 6.635 and 2.475 atmospheric pressure respectively. The other capsule with D, T, and He-3 at 2.475, 2.475, and 5.55 atmospheric pressure respectively. The capsules were imploded with 60 laser beams with a square pulse length of 0.6ns of total energy of 15.6 kJ. One-dimensional radiation hydrodynamic calculations with HYDRA and kinetic particle/hybrid simulations with LSP are carried out for the post-shot analysis. HYDRA outputs at 0.6ns are linked to LSP, in which the electrons are treated as a fluid while all the ion dynamics is simulated by the standard particle-in-cell technique. Additionally, simulations with the new photon package in LSP are initiated at the beginning of the implosion to include the implosion phase of the capsule. The simulation results of density, temperature, and velocity profiles of the electrons, D, T, He-3, and SiO2species are compared with HYDRA. Detail comparisons among the kinetic simulations, rad-hydro simulations, and experimental results of neutron yield, yield ratio, fusion burn histories, and shell convergence will be presented to assess plasma kinetic effects. Work performed under the auspices of the US DOE by the Los Alamos National Laboratory under Contract No. W7405-ENG-36.

  13. Protective Role of the Capsule and Impact of Serotype 4 Switching on Streptococcus mitis

    PubMed Central

    Rukke, Håkon V.; Kalluru, Raja Sab; Repnik, Urska; Gerlini, Alice; José, Ricardo J.; Periselneris, Jimstan; Marshall, Helina; Griffiths, Gareth; Oggioni, Marco Rinaldo; Brown, Jeremy S.

    2014-01-01

    The polysaccharide capsule surrounding Streptococcus pneumoniae is essential for virulence. Recently, Streptococcus mitis, a human commensal and a close relative of S. pneumoniae, was also shown to have a capsule. In this study, the S. mitis type strain switched capsule by acquisition of the serotype 4 capsule locus of S. pneumoniae TIGR4, following induction of competence for natural transformation. Comparison of the wild type with the capsule-switching mutant and with a capsule deletion mutant showed that the capsule protected S. mitis against phagocytosis by RAW 264.7 macrophages. This effect was enhanced in the S. mitis strain expressing the S. pneumoniae capsule, which showed, in addition, increased resistance against early clearance in a mouse model of lung infection. Expression of both capsules also favored survival in human blood, and the effect was again more pronounced for the capsule-switching mutant. S. mitis survival in horse blood or in a mouse model of bacteremia was not significantly different between the wild type and the mutant strains. In all models, S. pneumoniae TIGR4 showed higher rates of survival than the S. mitis type strain or the capsule-switching mutant, except in the lung model, in which significant differences between S. pneumoniae TIGR4 and the capsule-switching mutant were not observed. Thus, we identified conditions that showed a protective function for the capsule in S. mitis. Under such conditions, S. mitis resistance to clearance could be enhanced by capsule switching to serotype 4, but it was enhanced to levels lower than those for the virulent strain S. pneumoniae TIGR4. PMID:24958712

  14. Experimental investigation of a bioartificial capsule flowing in a narrow tube

    NASA Astrophysics Data System (ADS)

    Risso, Frédéric; Collé-Paillot, Fabienne; Zagzoule, Mokhtar

    This work is an experimental study of the motion and deformation of a bioartificial capsule flowing in a tube of 4 mm diameter. The capsules, initially designed for medical applications, are droplets of salt water surrounded by a thin polymeric membrane. They are immersed in a very viscous Newtonian silicone oil that flows through a tube in the Stokes regime. The properties of the capsules were carefully determined. Two previous experimental papers were devoted to their characterization by osmotic swelling and compression between two plates. The present work also provides a series of tests that allows an accurate definition of the experimental model under investigation. The capsules are buoyant and initially quasi-spherical. Nevertheless, buoyancy and small departures from sphericity are shown to have no significant effects, provided the flowing velocity is large enough for the viscous stress to become predominant. The capsules are also initially slightly over-inflated, but there is no mass transfer through the membrane during the present experiments. Their volume therefore remains constant. The membrane can be described as an elastic two-dimensional material, the elastic moduli of which are independent of the deformation. Far from the tube ends, the capsule reaches a steady state that depends on two parameters: the capillary number, Ca; and the ratio of the radius of the capsule to that of the tube, a/R. The capillary number, which compares the hydrodynamic stresses to the elastic tensions in the membrane, was varied between 0 and 0.125. The radius ratio, which measures the magnitude of the confinement, was varied from 0.75 to 0.95. In the range investigated, the membrane material always remains in the elastic domain. At fixed a/R, the capsule is stretched in the axial direction when Ca is increased. The process of deformation involves two main stages. At small to moderate Ca, the lateral dimension of the capsule decreases whereas its axial length increases. The

  15. Capsule Performance Optimization for the National Ignition Facility

    NASA Astrophysics Data System (ADS)

    Landen, Otto

    2009-11-01

    The overall goal of the capsule performance optimization campaign is to maximize the probability of ignition by experimentally correcting for likely residual uncertainties in the implosion and hohlraum physics used in our radiation-hydrodynamic computational models before proceeding to cryogenic-layered implosions and ignition attempts. This will be accomplished using a variety of targets that will set key laser, hohlraum and capsule parameters to maximize ignition capsule implosion velocity, while minimizing fuel adiabat, core shape asymmetry and ablator-fuel mix. The targets include high Z re-emission spheres setting foot symmetry through foot cone power balance [1], liquid Deuterium-filled ``keyhole'' targets setting shock speed and timing through the laser power profile [2], symmetry capsules setting peak cone power balance and hohlraum length [3], and streaked x-ray backlit imploding capsules setting ablator thickness [4]. We will show how results from successful tuning technique demonstration shots performed at the Omega facility under scaled hohlraum and capsule conditions relevant to the ignition design meet the required sensitivity and accuracy. We will also present estimates of all expected random and systematic uncertainties in setting the key ignition laser and target parameters due to residual measurement, calibration, cross-coupling, surrogacy, and scale-up errors, and show that these get reduced after a number of shots and iterations to meet an acceptable level of residual uncertainty. Finally, we will present results from upcoming tuning technique validation shots performed at NIF at near full-scale. Prepared by LLNL under Contract DE-AC52-07NA27344. [4pt] [1] E. Dewald, et. al. Rev. Sci. Instrum. 79 (2008) 10E903. [0pt] [2] T.R. Boehly, et. al., Phys. Plasmas 16 (2009) 056302. [0pt] [3] G. Kyrala, et. al., BAPS 53 (2008) 247. [0pt] [4] D. Hicks, et. al., BAPS 53 (2008) 2.

  16. 21 CFR 520.260 - n-Butyl chloride capsules.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 6 2011-04-01 2011-04-01 false n-Butyl chloride capsules. 520.260 Section 520.260 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS ORAL DOSAGE FORM NEW ANIMAL DRUGS § 520.260 n-Butyl chloride capsules...

  17. Controlled synthesis and facets-dependent photocatalysis of TiO2 nanocrystals

    NASA Astrophysics Data System (ADS)

    Roy, Nitish; Park, Yohan; Sohn, Youngku; Pradhan, Debabrata

    2015-04-01

    Titanium dioxide (TiO2) is a wide band gap semiconductor that has been extensively used in several environmental applications including degradation of organic hazardous chemicals, water splitting to generate hydrogen, dye sensitized solar cells, self cleaning agents, and pigments. Herein we demonstrate the synthesis of TiO2 nanocrystals (NCs) with the shapes of ellipsoids, rods, cuboids, and sheets with different exposed facets using a noncorrosive and nontoxic chemical (i.e. diethanolamine) as the shape controlling agent, unlike hydrofluoric acid commonly used. The TiO2 NCs of diverse shapes with different exposed facets were tested for photocatalytic hydroxyl radical (OH•) formation, which determines their photocatalytic behavior and the results were compared with the standard P-25 Degussa. The formation rate of OH• per specific surface area was found to be >6 fold higher for rod-shaped TiO2 NCs than that of commercial Degussa P25 catalyst. The highest photocatalytic activity of rod-shaped TiO2 NCs is ascribed to the unique chemical environment of {010} exposed facets which facilitates the electron/hole separation in presence of {101} facets.

  18. Rough surface scattering based on facet model

    NASA Technical Reports Server (NTRS)

    Khamsi, H. R.; Fung, A. K.; Ulaby, F. T.

    1974-01-01

    A model for the radar return from bare ground was developed to calculate the radar cross section of bare ground and the effect of the frequency averaging on the reduction of the variance of the return. It is shown that, by assuming that the distribution of the slope to be Gaussian and that the distribution of the length of the facet to be in the form of the positive side of a Gaussian distribution, the results are in good agreement with experimental data collected by an 8- to 18-GHz radar spectrometer system. It is also shown that information on the exact correlation length of the small structure on the ground is not necessary; an effective correlation length may be calculated based on the facet model and the wavelength of the incident wave.

  19. On the anatomy of the temporomandibular joint and the muscles that act upon it: observations on the gray whale, Eschrichtius robustus.

    PubMed

    El Adli, Joseph J; Deméré, Thomas A

    2015-04-01

    The temporomandibular joint and its associated musculature are described in a neonate gray whale (Eschrichtius robustus) and serve as the basis for direct anatomical comparisons with the temporomandibular region in other clades of baleen whales (Mysticeti). Members of the right whale/bowhead whale clade (Balaenidae) are known to possess a synovial lower jaw joint, while members of the rorqual clade (Balaenopteridae) have a nonsynovial temporomandibular joint characterized by a highly flexible fibrocartilaginous pad and no joint capsule. In contrast, the gray whale possesses a modified temporomandibular joint (intermediate condition), with a vestigial joint cavity lacking a fibrous capsule, synovial membrane, and articular disk. In addition, the presence of a rudimentary fibrocartilaginous pad appears to be homologous to that seen in balaenopterid mysticetes. The intrinsic temporomandibular musculature in the gray whale was found to include a multibellied superficial masseter and a single-bellied deep masseter. The digastric and internal pterygoid muscles in E. robustus are enlarged relative to the condition documented in species of Balaenoptera. A relatively complex insertion of the temporalis muscle on the dentary is documented in the gray whale and the low, knob-like process on the gray whale dentary is determined to be homologous with the prominent coronoid process of rorquals. Comparison with the anatomy of the temporomandibular musculature in rorquals reveals an increased importance of alpha rotation of the dentary in the gray whale. This difference in muscular morphology and lines of muscle action is interpreted as representing adaptations for suction feeding. © 2015 Wiley Periodicals, Inc.

  20. Sensory innervation of the temporomandibular joint in the mouse.

    PubMed

    Dreessen, D; Halata, Z; Strasmann, T

    1990-01-01

    The sensory innervation of the temporomandibular joints (TMJs) of 8 STR/IN mice was investigated by means of light and electron microscopy. Through the cutting of complete semithin sections in series it was possible to investigate the joints thoroughly. Additionally, one joint with its nerve supply was reconstructed three-dimensionally with a computerized three-dimensional programme. The reconstruction was based on one complete semithin section series. The joint's nerve supply originates from the nervus auriculotemporalis and additionally from motor branches of the n. mandibularis: n. massetericus, n. pterygoideus lateralis and the nn. temporales posteriores. The greatest number of nerve fibres and endings is located in the dorsolateral part of the joint capsule. They lie only in the stratum fibrosum and subsynovially. Neither the stratum synoviale nor the discus articularis contain any nerve fibres or endings, whereas the peri-articular loose connective tissue is richly innervated. The only type of nerve ending observed within the joint was the free nerve ending, which is assumed to serve not only as a nociceptor but also as a polymodal mechanoreceptor. Merely within the insertion of the musculus pterygoideus lateralis at the collum mandibulae single stretch receptors of the Ruffini type were observed. Ultrastructurally, they correspond to those described in the cat's knee joint. Neither lamellated nor nerve endings of the Golgi or Pacini type were observed in the joint or in the peri-articular connective tissue. The unexpected paucity of nerve fibres and endings in the TMJ itself of the mouse suggests that the afferent information from the joint is less important for position sense and movement than the afferent information from muscles, tendons and periodontal ligaments.

  1. A Model of Job Facet Satisfaction.

    ERIC Educational Resources Information Center

    Conway, Patricia G.; And Others

    1987-01-01

    Elements of the job that lead to overall job satisfaction were surveyed among public employees. The 17-facet model included promotion, training, supervisor, upper management, organization of work tasks, work stress, work challenge and autonomy, physical work space and equipment, work group, organizational structure, pay, etc. (Author/MH)

  2. Photometric model of diffuse surfaces described as a distribution of interfaced Lambertian facets.

    PubMed

    Simonot, Lionel

    2009-10-20

    The Lambertian model for diffuse reflection is widely used for the sake of its simplicity. Nevertheless, this model is known to be inaccurate in describing a lot of real-world objects, including those that present a matte surface. To overcome this difficulty, we propose a photometric model where the surfaces are described as a distribution of facets where each facet consists of a flat interface on a Lambertian background. Compared to the Lambertian model, it includes two additional physical parameters: an interface roughness parameter and the ratio between the refractive indices of the background binder and of the upper medium. The Torrance-Sparrow model--distribution of strictly specular facets--and the Oren-Nayar model--distribution of strictly Lambertian facets--appear as special cases.

  3. Stability of dronabinol capsules when stored frozen, refrigerated, or at room temperature.

    PubMed

    Wempe, Michael F; Oldland, Alan; Stolpman, Nancy; Kiser, Tyree H

    2016-07-15

    Results of a study to determine the 90-day stability of dronabinol capsules stored under various temperature conditions are reported. High-performance liquid chromatography (HPLC) with ultraviolet (UV) detection was used to assess the stability of dronabinol capsules (synthetic delta-9-tetrahydrocannabinol [Δ9-THC] mixed with high-grade sesame oil and other inactive ingredients and encapsulated as soft gelatin capsules) that were frozen, refrigerated, or kept at room temperature for three months. The dronabinol capsules remained in the original foil-sealed blister packs until preparation for HPLC-UV assessment. The primary endpoint was the percentage of the initial Δ9-THC concentration remaining at multiple designated time points. The secondary aim was to perform forced-degradation studies under acidic conditions to demonstrate that the HPLC-UV method used was stability indicating. The appearance of the dronabinol capsules remained unaltered during frozen, cold, or room-temperature storage. Regardless of storage condition, the percentage of the initial Δ9-THC content remaining was greater than 97% for all evaluated samples at all time points over the three-month study. These experimental data indicate that the product packaging and the sesame oil used to formulate dronabinol capsules efficiently protect Δ9-THC from oxidative degradation to cannabinol; this suggests that pharmacies can store dronabinol capsules in nonrefrigerated automated dispensing systems, with a capsule expiration date of 90 days after removal from the refrigerator. Dronabinol capsules may be stored at room temperature in their original packaging for up to three months without compromising capsule appearance and with minimal reduction in Δ9-THC concentration. Copyright © 2016 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  4. Therapeutic applications of radioactive (131)iodine: Procedures and incidents with capsules.

    PubMed

    Al Aamri, Marwa; Ravichandran, Ramamoorthy; Binukumar, John Pichy; Al Balushi, Naima

    2016-01-01

    Treatments for thyrotoxicosis and carcinoma thyroid are carried out by oral administration of radioactive iodine ((131)I) in the form of liquid or capsules. The liquid form of (131)I has higher risk factors such as vapourization, spillage and need for management of higher activity wastes. Use of (131)I in capsule form simplify procedures of handling compared to liquid form of (131)I. The guidelines of safe handling and quality assurance aspects for therapeutic use (131)I are well outlined by International Atomic Energy Agency (IAEA) reports. A few unusual incidents with I-131 capsules encountered in the past need to be highlighted from health physics point of view. In Royal Hospital, Oman, I-131 is imported in capsules, and the total activity handled/year steadily increased over 10 years. Discrete activities range from 185 MBq (5 mCi) up to 7.4 GBq (200 mCi). In four incidents deviations in standard operational procedures were recorded. Nature of incidents is described as follows: (1) After assay of activity, the capsule was directly put in the lead container with missing of inner cap. (2) Patient poured water in the Perspex tube, when the capsule was handed over to her, making an emergency situation. (3) In 3 high activity capsules (2 nos 2.96 GBq, 1 no. 4.26 GBq), observed sticky behavior in capsule holder on the 2(nd) day post receipt, which were in order on the 1(st) day. (4) A capsule could not be swallowed by a patient, which was taken back from the mouth. Monitoring of patient later did not show residual ingested activity. The report documents some of the unusual incidents for information to other centers engaged in such radioactive administrations.

  5. Capsule Endoscopy in Patients with Implantable Electromedical Devices is Safe

    PubMed Central

    Harris, Lucinda A.; Hansel, Stephanie L.; Rajan, Elizabeth; Srivathsan, Komandoor; Rea, Robert; Crowell, Michael D.; Fleischer, David E.; Pasha, Shabana F.; Gurudu, Suryakanth R.; Heigh, Russell I.; Shiff, Arthur D.; Post, Janice K.; Leighton, Jonathan A.

    2013-01-01

    Background and Study Aims. The presence of an implantable electromechanical cardiac device (IED) has long been considered a relative contraindication to the performance of video capsule endoscopy (CE). The primary aim of this study was to evaluate the safety of CE in patients with IEDs. A secondary purpose was to determine whether IEDs have any impact on images captured by CE. Patients and Methods. A retrospective chart review of all patients who had a capsule endoscopy at Mayo Clinic in Scottsdale, AZ, USA, or Rochester, MN, USA, (January 2002 to June 2010) was performed to identify CE studies done on patients with IEDs. One hundred and eighteen capsule studies performed in 108 patients with IEDs were identified and reviewed for demographic data, method of preparation, and study data. Results. The most common indications for CE were obscure gastrointestinal bleeding (77%), anemia (14%), abdominal pain (5%), celiac disease (2%), diarrhea (1%), and Crohn's disease (1%). Postprocedure assessments did not reveal any detectable alteration on the function of the IED. One patient with an ICD had a 25-minute loss of capsule imaging due to recorder defect. Two patients with LVADs had interference with capsule image acquisition. Conclusions. CE did not interfere with IED function, including PM, ICD, and/or LVAD and thus appears safe. Additionally, PM and ICD do not appear to interfere with image acquisition but LVAD may interfere with capsule images and require that capsule leads be positioned as far away as possible from the IED to assure reliable image acquisition. PMID:23710168

  6. Lordosis manoeuvre in the diagnosis of lumbar facet syndrome.

    PubMed

    Díez-Ulloa, M A; Almira Suárez, E L; Otero Fernández, M; Leborans Eiras, S; Collado Arce, G

    2016-01-01

    In lumbar pain patients an aetiopathogenic diagnosis leads to a better management. When there are alarm signs, they should be classified on an anatomical basis through anamnesis and physical examination. A significant group is of facet origin (lumbar facet syndrome [LFS]), but the precise clinical diagnosis remains cumbersome and time-consuming. In clinical practice it is observed that patients with an advanced degenerative disease do not perform extension or rotation of their lumbar spine when prompted to extend it, but rather knee flexion, making the manoeuvre meaningless. For this reason, a new simple and quick clinical test was developed for the diagnosis of lumbar facet syndrome, with a facet block-test as a confirmation. The new test is better than a classic one in the diagnosis of facet syndrome, and probably even better than imaging studies A prospective study was conducted on a series of 68 patients (01/01/2012-30/06/2013). A comparison in between: classic manoeuvre (CM), imaging diagnostics (ID), and the new lordosis manoeuvre (LM) test. Examination and block test by one author, and evaluation of results by another one. Deformity and instability. using a physical. To determine the effectiveness of a new clinical test (LM) for the diagnosis of LFS (as confirmed by a positive block-test of medial branch of dorsal ramus of the lumbar root, RMRDRL). R package software. The LM was most effective (p<.0001; Kappa 0.524, p<.001). There was no correlation between either the CM or ID and the block-test results (Kappa, CM: 0.078; p=.487, and ID: 0.195; p=.105). There was a correlation between ID (CAT/MR) and LM (p=.024; Kappa 0.289 p=.014), although not with CM. There was no correlation between ID (plain X-rays) and CM or LM. A new test for diagnosis of LFS is presented that is reliable, quick, and simple. Clinical examination is more reliable than imaging test for the diagnosis of LFS. Copyright © 2016 SECOT. Published by Elsevier Espana. All rights reserved.

  7. Clinical usefulness of novel tag-less Agile patency capsule prior to capsule endoscopy for patients with suspected small bowel stenosis.

    PubMed

    Nakamura, Masanao; Hirooka, Yoshiki; Yamamura, Takeshi; Miyahara, Ryoji; Watanabe, Osamu; Ando, Takafumi; Ohmiya, Naoki; Goto, Hidemi

    2015-01-01

    The Agile patency capsule (PC; Given Imaging Ltd, Yoqneam, Israel) is used as a dummy prior to capsule endoscopy (CE) to avoid retention of the CE capsule. However, impaction of the PC's inner radio frequency identification (RFID) tag in a stricture could cause small-bowel ileus. Recently, the RFID tag-less PC was introduced into clinical practice. Herein, we aimed to retrospectively evaluate the usefulness of the tag-less PC. Of 154 patients who were scheduled to undergo CE, 100 consecutive patients (65%) who underwent PC evaluation were enrolled in the present study. Primary study end point was the retention rate of the CE capsule after successful passage of the PC. Secondary end point was analysis of the significant factors affecting the passage of the PC. In total, 87 patients (87%) had bowel patency confirmed by PC evaluation. There was no capsule retention in any of these 87 patients during CE. Abnormal findings were obtained from 60 CE, and 41 patients received new or modified treatment. Multivariate analysis of factors related to the confirmation of patency demonstrated that stenosis on imaging was the most influential factor (P = 0.002, odds ratio 16.387). The results confirmed that passage of the PC depends on stenosis on imaging. Use of the tag-less PC confirmed gastrointestinal tract patency for most of the patients who did not have stenosis on imaging and allowed estimation of the patency for patients who did have stenosis on imaging. © 2014 The Authors. Digestive Endoscopy © 2014 Japan Gastroenterological Endoscopy Society.

  8. Intradiscal and intra-articular facet infiltrations with plasma rich in growth factors reduce pain in patients with chronic low back pain

    PubMed Central

    Kirchner, Fernando; Anitua, Eduardo

    2016-01-01

    Context: Low back pain (LBP) is a complex and disabling condition, and its treatment becomes a challenge. Aims: The aim of our study was to assess the clinical outcome of plasma rich in growth factors (PRGF-Endoret) infiltrations (one intradiscal, one intra-articular facet, and one transforaminal epidural injection) under fluoroscopic guidance-control in patients with chronic LBP. PRGF-Endoret which has been shown to be an efficient treatment to reduce joint pain. Settings and Design: The study was designed as an observational retrospective pilot study. Eighty-six patients with a history of chronic LBP and degenerative disease of the lumbar spine who met inclusion and exclusion criteria were recruited between December 2010 and January 2012. Subjects and Methods: One intradiscal, one intra-articular facet, and one transforaminal epidural injection of PRGF-Endoret under fluoroscopic guidance-control were carried out in 86 patients with chronic LBP in the operating theater setting. Statistical Analysis Used: Descriptive statistics were performed using absolute and relative frequency distributions for qualitative variables and mean values and standard deviations for quantitative variables. The nonparametric Friedman statistical test was used to determine the possible differences between baseline and different follow-up time points on pain reduction after treatment. Results: Pain assessment was determined using a visual analog scale (VAS) at the first visit before (baseline) and after the procedure at 1, 3, and 6 months. The pain reduction after the PRGF-Endoret injections showed a statistically significant drop from 8.4 ± 1.1 before the treatment to 4 ± 2.6, 1.7 ± 2.3, and 0.8 ± 1.7 at 1, 3, and 6 months after the treatment, respectively, with respect to all the time evaluations (P < 0.0001) except for the pain reduction between the 3rd and 6th month whose signification was lower (P < 0.05). The analysis of the VAS over time showed that at the end point of the

  9. Intradiscal and intra-articular facet infiltrations with plasma rich in growth factors reduce pain in patients with chronic low back pain.

    PubMed

    Kirchner, Fernando; Anitua, Eduardo

    2016-01-01

    Low back pain (LBP) is a complex and disabling condition, and its treatment becomes a challenge. The aim of our study was to assess the clinical outcome of plasma rich in growth factors (PRGF-Endoret) infiltrations (one intradiscal, one intra-articular facet, and one transforaminal epidural injection) under fluoroscopic guidance-control in patients with chronic LBP. PRGF-Endoret which has been shown to be an efficient treatment to reduce joint pain. The study was designed as an observational retrospective pilot study. Eighty-six patients with a history of chronic LBP and degenerative disease of the lumbar spine who met inclusion and exclusion criteria were recruited between December 2010 and January 2012. One intradiscal, one intra-articular facet, and one transforaminal epidural injection of PRGF-Endoret under fluoroscopic guidance-control were carried out in 86 patients with chronic LBP in the operating theater setting. Descriptive statistics were performed using absolute and relative frequency distributions for qualitative variables and mean values and standard deviations for quantitative variables. The nonparametric Friedman statistical test was used to determine the possible differences between baseline and different follow-up time points on pain reduction after treatment. Pain assessment was determined using a visual analog scale (VAS) at the first visit before (baseline) and after the procedure at 1, 3, and 6 months. The pain reduction after the PRGF-Endoret injections showed a statistically significant drop from 8.4 ± 1.1 before the treatment to 4 ± 2.6, 1.7 ± 2.3, and 0.8 ± 1.7 at 1, 3, and 6 months after the treatment, respectively, with respect to all the time evaluations ( P < 0.0001) except for the pain reduction between the 3 rd and 6 th month whose signification was lower ( P < 0.05). The analysis of the VAS over time showed that at the end point of the study (6 months), 91% of patients showed an excellent score, 8.1% showed a moderate

  10. Short article: Aspiration of capsule endoscopes: a comprehensive review of the existing literature.

    PubMed

    Yung, Diana E; Plevris, John N; Koulaouzidis, Anastasios

    2017-04-01

    Capsule endoscopy (CE) has an excellent safety profile. Although retention is the most cited complication, capsule aspiration is less frequent and is often reported only as isolated cases. This study represents a systematic effort to compile and scrutinize the available data on capsule aspiration to provide comprehensive and conclusive information on this CE complication. A systematic literature search was performed in PubMed, Embase and Chinese National Knowledge Infrastructure. The search terms used were 'capsule endoscopy' AND 'aspiration' (both terms searched as keyword and MeSH). We included case reports and/or series on capsule aspiration, as well as observational cohort studies that reported capsule aspiration among their complications/outcomes. Thirty-four case reports with 37 cases of capsule aspiration were identified. A further four observational studies reported aspiration as part of a cohort of patients undergoing CE. 94.6% of aspirations occurred in elderly men. 87.1% had significant comorbidities. 59.5% had symptoms on aspiration, with cough reported most frequently. The most common location of aspiration was the right main bronchus. Half of the patients required intervention for capsule retrieval; bronchoscopy was the most common management, with good effect. There was a single fatality following capsule aspiration, not directly related to the procedure, and one case of aspiration pneumonia. Outcomes were good for all other patients. The estimated overall aspiration rate is 0.1%. Although very rare and generally safely managed, capsule aspiration should be anticipated in certain patient groups and capsule administration should be approached with necessary precautions.

  11. Associations Between Egg Capsule Morphology and Predation Among Populations of the Marine Gastropod, Nucella emarginata.

    PubMed

    Rawlings, T A

    1990-12-01

    Intraspecific variation in the morphology of egg capsules is ideal for assessing the costs and benefits of encapsulation, yet little is known about the extent of such variation among populations of a single species. In the present study, I compared capsule morphology among three populations of the intertidal gastropod, Nucella emarginata. Significant differences were found both in capsule wall thickness and capsule strength. Mean capsule wall thickness varied as much as 25% among populations, with the dry weight of capsular cases differing accordingly. Capsule strength, measured as resistance to puncturing and squeezing forces, also varied among populations, but did not directly reflect differences in capsule wall thickness. Despite extensive variation in capsule morphology within this species, the number and size of eggs contained within capsules of equal volume did not differ significantly among populations. I also compared the type of capsule-eating predators that were present at each site. Shore crabs, Hemigrapsus spp., were abundant at all three sites; however, the predatory isopods Idotea wosnesenskii were only present at sites containing relatively thick-walled capsules. Although Hemigrapsus and Idotea were able to chew through both thick- and thin-walled capsules, laboratory experiments revealed that Idotea preferentially opened thin-walled capsules. These results suggest that variation in capsule morphology among populations of N. emarginata may, at least in part, reflect selection for the protection of embryos against predation.

  12. Radiation hydrodynamic effects in two beryllium plates with an idealized aluminum joint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Belkov, S.A.; Mkhitarian, L.S.; Vinokurov, O.A.

    A beryllium capsule formed from two hemispherical shells with a thin bond is one possible ignition target for the National Ignition Facility [J. A. Paisner {ital et al.}, Laser Focus World {bold 30}, 75 (1994)] Nonuniformities in density, opacity, and interface position at the joint between these hemishells will initiate two-dimensional (2-D) perturbations of the shock wave and material behind the shock as the shock passes through the shell perpendicular to the joint width. Rarefaction of material flow behind the shock front can cause the interface between the shell and joint material to oscillate in position. The amplitude of thesemore » oscillations may be comparable to the joint width. The evolution of these perturbations is studied by numerically simulating shock passage through flat beryllium plates containing aluminum joints. Using the MIMOSA-ND code [D. Sofronov {ital et al.}, Vopr. At. Nauki Tekh., Ser: Mat. modelirovanie fizicheskih processov {bold 2}, 3 (1990)] two different cases are calculated{emdash}a wide (10 {mu}m) and a narrow (1 {mu}m) joint of aluminum between two 150 {mu}m long semiinfinite beryllium plates. Both cases showed good agreement with an analytic representation of the oscillation behavior. For the narrow joint, a special technique allows the calculation of mixing between the joint and surrounding material caused by the Kelvin{endash}Helmholtz instability. {copyright} {ital 1999 American Institute of Physics.}« less

  13. First beryllium capsule implosions on the National Ignition Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kline, J. L.; Yi, S. A.; Simakov, A. N.

    2016-05-15

    The first indirect drive implosion experiments using Beryllium (Be) capsules at the National Ignition Facility confirm the superior ablation properties and elucidate possible Be-ablator issues such as hohlraum filling by ablator material. Since the 1990s, Be has been the preferred Inertial Confinement Fusion (ICF) ablator because of its higher mass ablation rate compared to that of carbon-based ablators. This enables ICF target designs with higher implosion velocities at lower radiation temperatures and improved hydrodynamic stability through greater ablative stabilization. Recent experiments to demonstrate the viability of Be ablator target designs measured the backscattered laser energy, capsule implosion velocity, core implosionmore » shape from self-emission, and in-flight capsule shape from backlit imaging. The laser backscatter is similar to that from comparable plastic (CH) targets under the same hohlraum conditions. Implosion velocity measurements from backlit streaked radiography show that laser energy coupling to the hohlraum wall is comparable to plastic ablators. The measured implosion shape indicates no significant reduction of laser energy from the inner laser cone beams reaching the hohlraum wall as compared with plastic and high-density carbon ablators. These results indicate that the high mass ablation rate for beryllium capsules does not significantly alter hohlraum energetics. In addition, these data, together with data for low fill-density hohlraum performance, indicate that laser power multipliers, required to reconcile simulations with experimental observations, are likely due to our limited understanding of the hohlraum rather than the capsule physics since similar multipliers are needed for both Be and CH capsules as seen in experiments.« less

  14. First beryllium capsule implosions on the National Ignition Facility

    DOE PAGES

    Kline, J. L.; Yi, S. A.; Simakov, A. N.; ...

    2016-05-01

    The first indirect drive implosion experiments using Beryllium (Be) capsules at the National Ignition Facility confirm the superior ablation properties and elucidate possible Be-ablator issues such as hohlraum filling by ablator material. Since the 1990s, Be has been the preferred Inertial Confinement Fusion (ICF) ablator because of its higher mass ablation rate compared to that of carbon-based ablators. This enables ICF target designs with higher implosion velocities at lower radiation temperatures and improved hydrodynamic stability through greater ablative stabilization. Recent experiments to demonstrate the viability of Be ablator target designs measured the backscattered laser energy, capsule implosion velocity, core implosionmore » shape from self-emission, and in-flight capsule shape from backlit imaging. The laser backscatter is similar to that from comparable plastic (CH) targets under the same hohlraum conditions. Implosion velocity measurements from backlit streaked radiography show that laser energy coupling to the hohlraum wall is comparable to plastic ablators. The measured implosion shape indicates no significant reduction of laser energy from the inner laser cone beams reaching the hohlraum wall as compared with plastic and high-density carbon ablators. These results indicate that the high mass ablation rate for beryllium capsules does not significantly alter hohlraum energetics. In addition, these data, together with data for low fill-density hohlraum performance, indicate that laser power multipliers, required to reconcile simulations with experimental observations, are likely due to our limited understanding of the hohlraum rather than the capsule physics since similar multipliers are needed for both Be and CH capsules as seen in experiments.« less

  15. Patterns of astragalar fibular facet orientation in extant and fossil primates and their evolutionary implications.

    PubMed

    Boyer, Doug M; Seiffert, Erik R

    2013-07-01

    A laterally sloping fibular facet of the astragalus (=talus) has been proposed as one of few osteological synapomorphies of strepsirrhine primates, but the feature has never been comprehensively quantified. We describe a method for calculating fibular facet orientation on digital models of astragali as the angle between the planes of the fibular facet and the lateral tibial facet. We calculated this value in a sample that includes all major extant primate clades, a diversity of Paleogene primates, and nonprimate euarchontans (n = 304). Results show that previous characterization of a divide between extant haplorhines and strepsirrhines is accurate, with little overlap even when individual data points are considered. Fibular facet orientation is conserved in extant strepsirrhines despite major differences in locomotion and body size, while extant anthropoids are more variable (e.g., low values for catarrhines relative to non-callitrichine platyrrhines). Euprimate outgroups exhibit a mosaic of character states with Cynocephalus having a more obtuse strepsirrhine-like facet and sampled treeshrews and plesiadapiforms having more acute haplorhine-like facets. Surprisingly, the earliest species of the adapiform Cantius have steep haplorhine-like facets as well. We used a Bayesian approach to reconstruct the evolution of fibular facet orientation as a continuous character across a supertree of living and extinct primates. Mean estimates for crown Primatomorpha (97.9°), Primates (99.5°), Haplorhini (98.7°), and Strepsirrhini (108.2°) support the hypothesis that the strepsirrhine condition is derived, while lower values for crown Anthropoidea (92.8°) and Catarrhini (88.9°) are derived in the opposite direction. Copyright © 2013 Wiley Periodicals, Inc.

  16. Capsule endoscopy of the future: What’s on the horizon?

    PubMed Central

    Slawinski, Piotr R; Obstein, Keith L; Valdastri, Pietro

    2015-01-01

    Capsule endoscopes have evolved from passively moving diagnostic devices to actively moving systems with potential therapeutic capability. In this review, we will discuss the state of the art, define the current shortcomings of capsule endoscopy, and address research areas that aim to overcome said shortcomings. Developments in capsule mobility schemes are emphasized in this text, with magnetic actuation being the most promising endeavor. Research groups are working to integrate sensor data and fuse it with robotic control to outperform today’s standard invasive procedures, but in a less intrusive manner. With recent advances in areas such as mobility, drug delivery, and therapeutics, we foresee a translation of interventional capsule technology from the bench-top to the clinical setting within the next 10 years. PMID:26457013

  17. The proposal of the locomotive system for capsule endoscopes.

    PubMed

    Watada, Masaya; Ozawa, Ken-ichi

    2008-01-01

    The capsule endoscope authorized in some countries in late years has the advantage of preparing the observation in difficult small intestines in a past endoscope. However, because the promotion mechanism of a capsule endoscope depends only on the peristaltic motion of a digestive organ, the oversight of change to a morbid state is feared. Authors aim at the achievement of a free movement and remote diagnoses in small intestines, and are developing a locomotive system for capsule endoscopes. This paper describes the proposal of the locomotive system with an electromagnetic actuator, and examination of a simulation model for this locomotive system.

  18. Biocatalytic response of multi-layer assembled collagen/hyaluronic acid nanoengineered capsules.

    PubMed

    Sousa, Fernanda; Kreft, Oliver; Sukhorukov, Gleb B; Möhwald, Helmuth; Kokol, Vanja

    2014-01-01

    Biodegradable hollow capsules filled with fluorescently labelled bovine serum albumin (BSA) as a model drug were prepared via layer-by-layer (LbL) self-assembly of type-I collagen (COL) and hyaluronic acid (HA) using calcium carbonate micro-particles and co-precipitation method. Capsules loaded with fluorescein isothiocyanate (FITC)-BSA, tetramethylrhodamin isothiocyanate (TRITC)-BSA or Alex-Fluor-488-BSA, respectively, were characterised before and after core removal using Confocal Laser Scanning Microscopy (CLSM), whilst the morphologies of individual hollow capsules were assessed using Atomic Force Microscopy (AFM). The sustained release of the encapsulated FITC-BSA protein was attained using enzymatic degradation of the capsule shells by collagenase. The released profile of the fluorescently-labelled BSA indicated that it could be successfully controlled by modulating the number of layers and/or by collagen crosslinking either before or after the capsule's assembly.

  19. Comparative study of antibiotic-containing polymethylmetacrylate capsules and beads.

    PubMed

    Borzsei, László; Mintál, Tibor; Horváth, Aranka; Koós, Zoltán; Kocsis, Béla; Nyárády, József

    2006-01-01

    This study aimed at making local antibiotic therapy wider in cases of chronic suppurations by administering antibiotics which previously could not be given in this way through the conventional polymethylmetacrylate (PMMA) carrier techniques. Capsules from this material were produced with a pressing machine designed and laid out by us. The characteristics of antibiotic penetration from this novel carrier were compared to those of PMMA beads. The time-dependent outflow of amikacin, clindamycin, pefloxacin, piperacillin + tazobactam, amoxicillin + clavulanic acid and cefotaxime was examined from the capsules and the beads with standard microbiological techniques using the Micrococcus luteus ATCC9341 test strain. The diameter of the inhibitory zones was measured after 24 h incubation at 37 degrees C and converted to mug/ml antibiotic concentrations. Our results revealed that all antibiotics showed longer-lasting and higher concentration outflow from the PMMA capsules than from the beads. Therefore, these capsules can provide a more promising new opportunity for specific local antimicrobial treatment in cases of chronic suppurative bone and soft tissue injuries. In these cases the polymerization has already been completed and the heat does not influence the structure of the antibiotics; therefore, it can be inserted into the capsules in powder or solution form. Copyright 2006 S. Karger AG, Basel.

  20. Effect of Counterflow Jet on a Supersonic Reentry Capsule

    NASA Technical Reports Server (NTRS)

    Chang, Chau-Lyan; Venkatachari, Balaji Shankar; Cheng, Gary C.

    2006-01-01

    Recent NASA initiatives for space exploration have reinvigorated research on Apollo-like capsule vehicles. Aerothermodynamic characteristics of these capsule configurations during reentry play a crucial role in the performance and safety of the planetary entry probes and the crew exploration vehicles. At issue are the forebody thermal shield protection and afterbody aeroheating predictions. Due to the lack of flight or wind tunnel measurements at hypersonic speed, design decisions on such vehicles would rely heavily on computational results. Validation of current computational tools against experimental measurement thus becomes one of the most important tasks for general hypersonic research. This paper is focused on time-accurate numerical computations of hypersonic flows over a set of capsule configurations, which employ a counterflow jet to offset the detached bow shock. The accompanying increased shock stand-off distance and modified heat transfer characteristics associated with the counterflow jet may provide guidance for future design of hypersonic reentry capsules. The newly emerged space-time conservation element solution element (CESE) method is used to perform time-accurate, unstructured mesh Navier-Stokes computations for all cases investigated. The results show good agreement between experimental and numerical Schlieren pictures. Surface heat flux and aerodynamic force predictions of the capsule configurations are discussed in detail.