Sample records for facial electromyography emg

  1. Using State-Space Model with Regime Switching to Represent the Dynamics of Facial Electromyography (EMG) Data

    ERIC Educational Resources Information Center

    Yang, Manshu; Chow, Sy-Miin

    2010-01-01

    Facial electromyography (EMG) is a useful physiological measure for detecting subtle affective changes in real time. A time series of EMG data contains bursts of electrical activity that increase in magnitude when the pertinent facial muscles are activated. Whereas previous methods for detecting EMG activation are often based on deterministic or…

  2. Investigating Facial Electromyography as an Indicator of Cognitive Workload

    DTIC Science & Technology

    2017-02-22

    Investigating Facial Electromyography as an Indicator of Cognitive Workload 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d...Symposium on Aviation Psychology (ISAP) 9 – 11 May 2017 14. ABSTRACT Facial electromyography (fEMG) is an electromyographic measurement technique... cognitive workload. In the current study, two task-irrelevant facial muscles, corrugator supercilli and lateral frontalis, were monitored in real- time to

  3. Usefulness of BFB/EMG in facial palsy rehabilitation.

    PubMed

    Dalla Toffola, Elena; Bossi, Daniela; Buonocore, Michelangelo; Montomoli, Cristina; Petrucci, Lucia; Alfonsi, Enrico

    2005-07-22

    To analyze and to compare the recovery and the development of synkinesis in patients with idiopathic facial palsy (Bell's palsy) following treatment with two methods of rehabilitation, kinesitherapy (KT) and biofeedback/EMG (BFB/EMG). Retrospective cases--series review. Seventy-four patients with Bell' palsy were clinically evaluated within 1 month from onset of palsy and at 12 months after palsy (House scale and synkinesis evaluation). Electromyography (EMG) and Electroneurography (ENG) were performed about 4 weeks after palsy to better evaluate functional abnormalities due to facial nerve lesion. The patients followed two different protocols for rehabilitation: the first 32 patients were treated with therapeutic exercises performed by therapists (KT group), the latter 42 patients were treated using BFB/EMG methods (BFB group) with inhibition of synkinetic movement as the primary goal. KT and BFB patients were evaluated for clinical and neurophysiological characteristics before rehabilitative treatment. BFB patients showed better clinical recovery and minor synkinesis than KT patients. BFB/EMG seems to be more useful than KT in Bell's palsy treatment. This could be due to the fact that BFB/EMG gives more accurate information than KT on muscle activation with better modulation in voluntary recruitment of motor unit.

  4. Quantitative facial electromyography monitoring after hypoglossal‐facial jump nerve suture

    PubMed Central

    Flasar, Jan; Volk, Gerd Fabian; Granitzka, Thordis; Geißler, Katharina; Irintchev, Andrey; Lehmann, Thomas

    2017-01-01

    Objectives/Hypothesis The time course of the reinnervation of the paralyzed face after hypoglossal‐facial jump nerve suture using electromyography (EMG) was assessed. The relation to the clinical outcome was analyzed. Study Design Retrospective single‐center cohort study Methods Reestablishment of motor units was studied by quantitative EMG and motor unit potential (MUP) analysis in 11 patients after hypoglossal‐facial jump nerve suture. Functional recovery was evaluated using the Stennert index (0 = normal; 10 = maximal palsy). Results Clinically, first movements were seen between 6 and >10 months after surgery in individual patients. Maximal improvement was achieved at 18 months. The Stennert index decreased from 7.9 ± 2.0 preoperatively to a final postoperative score of 5.8 ± 2.4. EMG monitoring performed for 2.8 to 60 months after surgery revealed that pathological spontaneous activity disappeared within 2 weeks. MUPs were first recorded after the 2nd month and present in all 11 patients 8–10 months post‐surgery. Polyphasic regeneration potentials first appeared at 4–10 months post‐surgery. The MUP amplitudes increased between the 3rd and 15th months after surgery to values of control muscles. The MUP duration was significantly increased above normal values between the 3rd and 24th months after surgery. Conclusion Reinnervation can be detected at least 2 months earlier by EMG than by clinical evaluation. Changes should be followed for at least 18 months to assess outcome. EMG changes reflected the remodeling of motor units due to axonal regeneration and collateral sprouting by hypoglossal nerve fibers into the reinnervated facial muscle fibers. Level of Evidence 3b. PMID:29094077

  5. Undifferentiated Facial Electromyography Responses to Dynamic, Audio-Visual Emotion Displays in Individuals with Autism Spectrum Disorders

    ERIC Educational Resources Information Center

    Rozga, Agata; King, Tricia Z.; Vuduc, Richard W.; Robins, Diana L.

    2013-01-01

    We examined facial electromyography (fEMG) activity to dynamic, audio-visual emotional displays in individuals with autism spectrum disorders (ASD) and typically developing (TD) individuals. Participants viewed clips of happy, angry, and fearful displays that contained both facial expression and affective prosody while surface electrodes measured…

  6. Knowledge of electromyography (EMG) in patients undergoing EMG examinations

    PubMed Central

    Mondelli, Mauro; Aretini, Alessandro; Greco, Giuseppe

    2014-01-01

    Summary The aim of this study was to evaluate knowledge of electromyography (EMG) in patients undergoing the procedure. In one year, 1,586 consecutive patients (mean age 56 years; 58.8% women) were admitted to two EMG labs to undergo EMG for the first time. The patients found to be “informed” about the how an EMG examination is performed and about the purpose of EMG numbered 448 (28.2%), while those found to be “informed” only about the manner of its execution or only about its purpose numbered 161 (10.2%) and 151 (9.5%), respectively. The remaining 826 (52.1%) patients had either no information, or the information they had was very poor or incorrect (this was particularly true if they had been consulting websites). Being “informed” was associated with level of education (high), type of referring physician (specialist) and with an appropriate referral diagnosis specified in the EMG request. The quality of patient information on EMG was found to be very poor and could be improved. Physicians referring patients for EMG examinations, especially general practitioners, should assume primary responsibility for patient education and counseling in this field. PMID:25473740

  7. Coherence explored between emotion components: evidence from event-related potentials and facial electromyography.

    PubMed

    Gentsch, Kornelia; Grandjean, Didier; Scherer, Klaus R

    2014-04-01

    Componential theories assume that emotion episodes consist of emergent and dynamic response changes to relevant events in different components, such as appraisal, physiology, motivation, expression, and subjective feeling. In particular, Scherer's Component Process Model hypothesizes that subjective feeling emerges when the synchronization (or coherence) of appraisal-driven changes between emotion components has reached a critical threshold. We examined the prerequisite of this synchronization hypothesis for appraisal-driven response changes in facial expression. The appraisal process was manipulated by using feedback stimuli, presented in a gambling task. Participants' responses to the feedback were investigated in concurrently recorded brain activity related to appraisal (event-related potentials, ERP) and facial muscle activity (electromyography, EMG). Using principal component analysis, the prediction of appraisal-driven response changes in facial EMG was examined. Results support this prediction: early cognitive processes (related to the feedback-related negativity) seem to primarily affect the upper face, whereas processes that modulate P300 amplitudes tend to predominantly drive cheek region responses. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. Acoustic (loudspeaker) facial EMG monitoring: II. Use of evoked EMG activity during acoustic neuroma resection.

    PubMed

    Prass, R L; Kinney, S E; Hardy, R W; Hahn, J F; Lüders, H

    1987-12-01

    Facial electromyographic (EMG) activity was continuously monitored via loudspeaker during eleven translabyrinthine and nine suboccipital consecutive unselected acoustic neuroma resections. Ipsilateral facial EMG activity was synchronously recorded on the audio channels of operative videotapes, which were retrospectively reviewed in order to allow detailed evaluation of the potential benefit of various acoustic EMG patterns in the performance of specific aspects of acoustic neuroma resection. The use of evoked facial EMG activity was classified and described. Direct local mechanical (surgical) stimulation and direct electrical stimulation were of benefit in the localization and/or delineation of the facial nerve contour. Burst and train acoustic patterns of EMG activity appeared to indicate surgical trauma to the facial nerve that would not have been appreciated otherwise. Early results of postoperative facial function of monitored patients are presented, and the possible value of burst and train acoustic EMG activity patterns in the intraoperative assessment of facial nerve function is discussed. Acoustic facial EMG monitoring appears to provide a potentially powerful surgical tool for delineation of the facial nerve contour, the ongoing use of which may lead to continued improvement in facial nerve function preservation through modification of dissection strategy.

  9. Discrete vs. Continuous Mapping of Facial Electromyography for Human-Machine-Interface Control: Performance and Training Effects

    PubMed Central

    Cler, Meredith J.; Stepp, Cara E.

    2015-01-01

    Individuals with high spinal cord injuries are unable to operate a keyboard and mouse with their hands. In this experiment, we compared two systems using surface electromyography (sEMG) recorded from facial muscles to control an onscreen keyboard to type five-letter words. Both systems used five sEMG sensors to capture muscle activity during five distinct facial gestures that were mapped to five cursor commands: move left, move right, move up, move down, and “click”. One system used a discrete movement and feedback algorithm in which the user produced one quick facial gesture, causing a corresponding discrete movement to an adjacent letter. The other system was continuously updated and allowed the user to control the cursor’s velocity by relative activation between different sEMG channels. Participants were trained on one system for four sessions on consecutive days, followed by one crossover session on the untrained system. Information transfer rates (ITRs) were high for both systems compared to other potential input modalities, both initially and with training (Session 1: 62.1 bits/min, Session 4: 105.1 bits/min). Users of the continuous system showed significantly higher ITRs than the discrete users. Future development will focus on improvements to both systems, which may offer differential advantages for users with various motor impairments. PMID:25616053

  10. Intraoperative identification of the facial nerve by needle electromyography stimulation with a burr

    PubMed Central

    KHAMGUSHKEEVA, N.N.; ANIKIN, I.A.; KORNEYENKOV, A.A.

    2016-01-01

    The purpose of this research is to improve the safety of surgery for patients with a pathology of the middle and inner ear by preventing damage to the facial nerve by conducting intraoperative monitoring of the facial nerve by needle electromyography with continuous stimulation with a burr. Patients and Methods The clinical part of the prospective study was carried out on 48 patients that were diagnosed with suppurative otitis media. After the surgery with intraoperative monitoring, the facial nerve with an intact bone wall was stimulated electrically in the potentially dangerous places of damage. Minimum (threshold) stimulation (mA) of the facial nerve with a threshold event of 100 μV was used to register EMG events. The anatomical part of the study was carried out on 30 unformalinized cadaver temporal bones from adult bodies. The statistical analysis of obtained data was carried out with parametric methods (Student’s t-test), non-parametric correlation (Spearman’s method) and regression analysis. Results It was found that 1 mA of threshold amperage corresponded to 0.8 mm thickness of the bone wall of the facial canal. Values of transosseous threshold stimulation in potentially dangerous sections of the injury to the facial nerve were obtained. Conclusion These data lower the risk of paresis (paralysis) of the facial muscles during otologic surgery. PMID:27142821

  11. Rapid Facial Reactions to Emotional Facial Expressions in Typically Developing Children and Children with Autism Spectrum Disorder

    ERIC Educational Resources Information Center

    Beall, Paula M.; Moody, Eric J.; McIntosh, Daniel N.; Hepburn, Susan L.; Reed, Catherine L.

    2008-01-01

    Typical adults mimic facial expressions within 1000ms, but adults with autism spectrum disorder (ASD) do not. These rapid facial reactions (RFRs) are associated with the development of social-emotional abilities. Such interpersonal matching may be caused by motor mirroring or emotional responses. Using facial electromyography (EMG), this study…

  12. Human joint motion estimation for electromyography (EMG)-based dynamic motion control.

    PubMed

    Zhang, Qin; Hosoda, Ryo; Venture, Gentiane

    2013-01-01

    This study aims to investigate a joint motion estimation method from Electromyography (EMG) signals during dynamic movement. In most EMG-based humanoid or prosthetics control systems, EMG features were directly or indirectly used to trigger intended motions. However, both physiological and nonphysiological factors can influence EMG characteristics during dynamic movements, resulting in subject-specific, non-stationary and crosstalk problems. Particularly, when motion velocity and/or joint torque are not constrained, joint motion estimation from EMG signals are more challenging. In this paper, we propose a joint motion estimation method based on muscle activation recorded from a pair of agonist and antagonist muscles of the joint. A linear state-space model with multi input single output is proposed to map the muscle activity to joint motion. An adaptive estimation method is proposed to train the model. The estimation performance is evaluated in performing a single elbow flexion-extension movement in two subjects. All the results in two subjects at two load levels indicate the feasibility and suitability of the proposed method in joint motion estimation. The estimation root-mean-square error is within 8.3% ∼ 10.6%, which is lower than that being reported in several previous studies. Moreover, this method is able to overcome subject-specific problem and compensate non-stationary EMG properties.

  13. Wireless electronic-tattoo for long-term high fidelity facial muscle recordings

    NASA Astrophysics Data System (ADS)

    Inzelberg, Lilah; David Pur, Moshe; Steinberg, Stanislav; Rand, David; Farah, Maroun; Hanein, Yael

    2017-05-01

    Facial surface electromyography (sEMG) is a powerful tool for objective evaluation of human facial expressions and was accordingly suggested in recent years for a wide range of psychological and neurological assessment applications. Owing to technical challenges, in particular the cumbersome gelled electrodes, the use of facial sEMG was so far limited. Using innovative facial temporary tattoos optimized specifically for facial applications, we demonstrate the use of sEMG as a platform for robust identification of facial muscle activation. In particular, differentiation between diverse facial muscles is demonstrated. We also demonstrate a wireless version of the system. The potential use of the presented technology for user-experience monitoring and objective psychological and neurological evaluations is discussed.

  14. Using facial electromyography to detect preserved emotional processing in disorders of consciousness: A proof-of-principle study.

    PubMed

    Fiacconi, Chris M; Owen, Adrian M

    2016-09-01

    To examine whether emotional functioning can be observed in patients who are behaviourally non-responsive using peripheral markers of emotional functioning. We tested two patients, both diagnosed as being in a vegetative state (VS) following hypoxia secondary to cardiac arrest. Thirty-seven healthy participants with no history of neurological illness served as a control group. The activity of two facial muscles (zygomaticus major, corrugator supercilii) was measured using facial electromyography (EMG) to probe for patterned responses that differentiate between auditorily presented joke and non-joke stimuli in VS patients. One of the two VS patients we tested demonstrated greater zygomatic and reduced corrugator activity in response to jokes compared with non-jokes. Critically, these responses followed the pattern and temporal profile of muscle activity observed in our healthy control sample. Despite their behaviorally non-responsive profile, some patients diagnosed as VS appear to retain some aspects of emotional experience. Our findings represent, to our knowledge, the first demonstration that a patient diagnosed as VS can exhibit intact emotional responses to humor as assessed by facial EMG. Therefore, our approach may constitute a feasible bedside tool capable of providing novel insight into the mental and emotional lives of patients who are behaviourally non-responsive. Copyright © 2016 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  15. The role of emotion in learning trustworthiness from eye-gaze: Evidence from facial electromyography

    PubMed Central

    Manssuer, Luis R.; Pawling, Ralph; Hayes, Amy E.; Tipper, Steven P.

    2016-01-01

    Gaze direction can be used to rapidly and reflexively lead or mislead others’ attention as to the location of important stimuli. When perception of gaze direction is congruent with the location of a target, responses are faster compared to when incongruent. Faces that consistently gaze congruently are also judged more trustworthy than faces that consistently gaze incongruently. However, it’s unclear how gaze-cues elicit changes in trust. We measured facial electromyography (EMG) during an identity-contingent gaze-cueing task to examine whether embodied emotional reactions to gaze-cues mediate trust learning. Gaze-cueing effects were found to be equivalent regardless of whether participants showed learning of trust in the expected direction or did not. In contrast, we found distinctly different patterns of EMG activity in these two populations. In a further experiment we showed the learning effects were specific to viewing faces, as no changes in liking were detected when viewing arrows that evoked similar attentional orienting responses. These findings implicate embodied emotion in learning trust from identity-contingent gaze-cueing, possibly due to the social value of shared attention or deception rather than domain-general attentional orienting. PMID:27153239

  16. Emotional facial expressions evoke faster orienting responses, but weaker emotional responses at neural and behavioural levels compared to scenes: A simultaneous EEG and facial EMG study.

    PubMed

    Mavratzakis, Aimee; Herbert, Cornelia; Walla, Peter

    2016-01-01

    In the current study, electroencephalography (EEG) was recorded simultaneously with facial electromyography (fEMG) to determine whether emotional faces and emotional scenes are processed differently at the neural level. In addition, it was investigated whether these differences can be observed at the behavioural level via spontaneous facial muscle activity. Emotional content of the stimuli did not affect early P1 activity. Emotional faces elicited enhanced amplitudes of the face-sensitive N170 component, while its counterpart, the scene-related N100, was not sensitive to emotional content of scenes. At 220-280ms, the early posterior negativity (EPN) was enhanced only slightly for fearful as compared to neutral or happy faces. However, its amplitudes were significantly enhanced during processing of scenes with positive content, particularly over the right hemisphere. Scenes of positive content also elicited enhanced spontaneous zygomatic activity from 500-750ms onwards, while happy faces elicited no such changes. Contrastingly, both fearful faces and negative scenes elicited enhanced spontaneous corrugator activity at 500-750ms after stimulus onset. However, relative to baseline EMG changes occurred earlier for faces (250ms) than for scenes (500ms) whereas for scenes activity changes were more pronounced over the whole viewing period. Taking into account all effects, the data suggests that emotional facial expressions evoke faster attentional orienting, but weaker affective neural activity and emotional behavioural responses compared to emotional scenes. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  17. Neural Correlates of Facial Mimicry: Simultaneous Measurements of EMG and BOLD Responses during Perception of Dynamic Compared to Static Facial Expressions

    PubMed Central

    Rymarczyk, Krystyna; Żurawski, Łukasz; Jankowiak-Siuda, Kamila; Szatkowska, Iwona

    2018-01-01

    Facial mimicry (FM) is an automatic response to imitate the facial expressions of others. However, neural correlates of the phenomenon are as yet not well established. We investigated this issue using simultaneously recorded EMG and BOLD signals during perception of dynamic and static emotional facial expressions of happiness and anger. During display presentations, BOLD signals and zygomaticus major (ZM), corrugator supercilii (CS) and orbicularis oculi (OO) EMG responses were recorded simultaneously from 46 healthy individuals. Subjects reacted spontaneously to happy facial expressions with increased EMG activity in ZM and OO muscles and decreased CS activity, which was interpreted as FM. Facial muscle responses correlated with BOLD activity in regions associated with motor simulation of facial expressions [i.e., inferior frontal gyrus, a classical Mirror Neuron System (MNS)]. Further, we also found correlations for regions associated with emotional processing (i.e., insula, part of the extended MNS). It is concluded that FM involves both motor and emotional brain structures, especially during perception of natural emotional expressions. PMID:29467691

  18. Congenital multiple cranial neuropathies: Relevance of orofacial electromyography in infants.

    PubMed

    Renault, Francis; Flores-Guevara, Roberto; Baudon, Jean-Jacques; Vazquez, Marie-Paule

    2015-11-01

    The aim of this study was to assess diagnoses and outcomes of infants with 2 or more cranial neuropathies identified using orofacial electromyography (EMG). This retrospective study involved 90 patients. Diagnoses took into account clinical, radiological, and genetic data. EMG examined the orbicularis oculi, genioglossus, and levator veli palatini muscles, and blink responses. To evaluate outcome, neurological disability, respiratory complications, and feeding difficulties were recorded. The patients had malformation syndromes (59), encephalopathies (29), or no underlying disorders (2). Neurogenic EMG signs were detected in a mean of 4 muscles, reflecting a mean of 3 affected nerves. EMG identified a higher number of neuropathies than clinical examination alone (82 vs. 31, facial; 56 vs. 2, pharyngeal; 25 vs. 3, hypoglossal). Poor outcome and death were more frequent when EMG identified ≥4 affected nerves (P = 0.02). EMG highlights multiple cranial neuropathies that can be clinically silent in infants with malformation syndromes or encephalopathies. © 2015 Wiley Periodicals, Inc.

  19. Evidence of emotion-antecedent appraisal checks in electroencephalography and facial electromyography

    PubMed Central

    Scherer, Klaus R.; Schuller, Björn W.

    2018-01-01

    In the present study, we applied Machine Learning (ML) methods to identify psychobiological markers of cognitive processes involved in the process of emotion elicitation as postulated by the Component Process Model (CPM). In particular, we focused on the automatic detection of five appraisal checks—novelty, intrinsic pleasantness, goal conduciveness, control, and power—in electroencephalography (EEG) and facial electromyography (EMG) signals. We also evaluated the effects on classification accuracy of averaging the raw physiological signals over different numbers of trials, and whether the use of minimal sets of EEG channels localized over specific scalp regions of interest are sufficient to discriminate between appraisal checks. We demonstrated the effectiveness of our approach on two data sets obtained from previous studies. Our results show that novelty and power appraisal checks can be consistently detected in EEG signals above chance level (binary tasks). For novelty, the best classification performance in terms of accuracy was achieved using features extracted from the whole scalp, and by averaging across 20 individual trials in the same experimental condition (UAR = 83.5 ± 4.2; N = 25). For power, the best performance was obtained by using the signals from four pre-selected EEG channels averaged across all trials available for each participant (UAR = 70.6 ± 5.3; N = 24). Together, our results indicate that accurate classification can be achieved with a relatively small number of trials and channels, but that averaging across a larger number of individual trials is beneficial for the classification for both appraisal checks. We were not able to detect any evidence of the appraisal checks under study in the EMG data. The proposed methodology is a promising tool for the study of the psychophysiological mechanisms underlying emotional episodes, and their application to the development of computerized tools (e.g., Brain-Computer Interface) for the study of

  20. Evidence of emotion-antecedent appraisal checks in electroencephalography and facial electromyography.

    PubMed

    Coutinho, Eduardo; Gentsch, Kornelia; van Peer, Jacobien; Scherer, Klaus R; Schuller, Björn W

    2018-01-01

    In the present study, we applied Machine Learning (ML) methods to identify psychobiological markers of cognitive processes involved in the process of emotion elicitation as postulated by the Component Process Model (CPM). In particular, we focused on the automatic detection of five appraisal checks-novelty, intrinsic pleasantness, goal conduciveness, control, and power-in electroencephalography (EEG) and facial electromyography (EMG) signals. We also evaluated the effects on classification accuracy of averaging the raw physiological signals over different numbers of trials, and whether the use of minimal sets of EEG channels localized over specific scalp regions of interest are sufficient to discriminate between appraisal checks. We demonstrated the effectiveness of our approach on two data sets obtained from previous studies. Our results show that novelty and power appraisal checks can be consistently detected in EEG signals above chance level (binary tasks). For novelty, the best classification performance in terms of accuracy was achieved using features extracted from the whole scalp, and by averaging across 20 individual trials in the same experimental condition (UAR = 83.5 ± 4.2; N = 25). For power, the best performance was obtained by using the signals from four pre-selected EEG channels averaged across all trials available for each participant (UAR = 70.6 ± 5.3; N = 24). Together, our results indicate that accurate classification can be achieved with a relatively small number of trials and channels, but that averaging across a larger number of individual trials is beneficial for the classification for both appraisal checks. We were not able to detect any evidence of the appraisal checks under study in the EMG data. The proposed methodology is a promising tool for the study of the psychophysiological mechanisms underlying emotional episodes, and their application to the development of computerized tools (e.g., Brain-Computer Interface) for the study of

  1. Repetitive nerve stimulation and single-fiber electromyography in the evaluation of patients with suspected myasthenia gravis or Lambert-Eaton myasthenic syndrome: Review of recent literature.

    PubMed

    Chiou-Tan, Faye Y; Gilchrist, James M

    2015-09-01

    Our aim in this study was to provide an updated literature review of electrodiagnostic testing in myasthenia gravis and Lambert-Eaton myasthenic syndrome. A systematic review of the recent literature was performed using the following key words: myasthenia gravis (MG); Lambert-Eaton myasthenic syndrome (LEMS); electromyography (EMG); repetitive nerve stimulation (RNS); single-fiber electromyography (SFEMG); nerve conduction study; and normative values. Several articles supported testing of facial, bulbar, and respiratory muscles in the diagnosis of neuromuscular junction (NMJ) disorders, including muscle-specific kinase antibody (MuSK)-seropositive MG. Several articles supported use of concentric needle EMG as an alternative to SFEMG jitter in disorders of neuromuscular transmission. A limited number of articles addressed measurement of area (vs. amplitude) decrement in RNS and decreasing the threshold of post-exercise facilitation. Electrodiagnostic testing continues to be useful for diagnosis of MG and LEMS, although the quality of the evidence is not great. This literature review summarizes RNS and jitter measurement of facial and respiratory muscles and use of concentric needle EMG for SFEMG. © 2015 American Association of Neuromuscular and Electrodiagnostic Medicine.

  2. Suboptimal Exposure to Facial Expressions When Viewing Video Messages From a Small Screen: Effects on Emotion, Attention, and Memory

    ERIC Educational Resources Information Center

    Ravaja, Niklas; Kallinen, Kari; Saari, Timo; Keltikangas-Jarvinen, Liisa

    2004-01-01

    The authors examined the effects of suboptimally presented facial expressions on emotional and attentional responses and memory among 39 young adults viewing video (business news) messages from a small screen. Facial electromyography (EMG) and respiratory sinus arrhythmia were used as physiological measures of emotion and attention, respectively.…

  3. Electromyography (EMG) signal recognition using combined discrete wavelet transform based adaptive neuro-fuzzy inference systems (ANFIS)

    NASA Astrophysics Data System (ADS)

    Arozi, Moh; Putri, Farika T.; Ariyanto, Mochammad; Khusnul Ari, M.; Munadi, Setiawan, Joga D.

    2017-01-01

    People with disabilities are increasing from year to year either due to congenital factors, sickness, accident factors and war. One form of disability is the case of interruptions of hand function. The condition requires and encourages the search for solutions in the form of creating an artificial hand with the ability as a human hand. The development of science in the field of neuroscience currently allows the use of electromyography (EMG) to control the motion of artificial prosthetic hand into the necessary use of EMG as an input signal to control artificial prosthetic hand. This study is the beginning of a significant research planned in the development of artificial prosthetic hand with EMG signal input. This initial research focused on the study of EMG signal recognition. Preliminary results show that the EMG signal recognition using combined discrete wavelet transform and Adaptive Neuro-Fuzzy Inference System (ANFIS) produces accuracy 98.3 % for training and 98.51% for testing. Thus the results can be used as an input signal for Simulink block diagram of a prosthetic hand that will be developed on next study. The research will proceed with the construction of artificial prosthetic hand along with Simulink program controlling and integrating everything into one system.

  4. Facial EMG responses to emotional expressions are related to emotion perception ability.

    PubMed

    Künecke, Janina; Hildebrandt, Andrea; Recio, Guillermo; Sommer, Werner; Wilhelm, Oliver

    2014-01-01

    Although most people can identify facial expressions of emotions well, they still differ in this ability. According to embodied simulation theories understanding emotions of others is fostered by involuntarily mimicking the perceived expressions, causing a "reactivation" of the corresponding mental state. Some studies suggest automatic facial mimicry during expression viewing; however, findings on the relationship between mimicry and emotion perception abilities are equivocal. The present study investigated individual differences in emotion perception and its relationship to facial muscle responses - recorded with electromyogram (EMG)--in response to emotional facial expressions. N° = °269 participants completed multiple tasks measuring face and emotion perception. EMG recordings were taken from a subsample (N° = °110) in an independent emotion classification task of short videos displaying six emotions. Confirmatory factor analyses of the m. corrugator supercilii in response to angry, happy, sad, and neutral expressions showed that individual differences in corrugator activity can be separated into a general response to all faces and an emotion-related response. Structural equation modeling revealed a substantial relationship between the emotion-related response and emotion perception ability, providing evidence for the role of facial muscle activation in emotion perception from an individual differences perspective.

  5. Temporal Taylor's scaling of facial electromyography and electrodermal activity in the course of emotional stimulation

    NASA Astrophysics Data System (ADS)

    Chołoniewski, Jan; Chmiel, Anna; Sienkiewicz, Julian; Hołyst, Janusz A.; Küster, Dennis; Kappas, Arvid

    2016-09-01

    High frequency psychophysiological data create a challenge for quantitative modeling based on Big Data tools since they reflect the complexity of processes taking place in human body and its responses to external events. Here we present studies of fluctuations in facial electromyography (fEMG) and electrodermal activity (EDA) massive time series and changes of such signals in the course of emotional stimulation. Zygomaticus major (ZYG, "smiling" muscle) activity, corrugator supercilii (COR, "frowning"bmuscle) activity, and phasic skin conductance (PHSC, sweating) levels of 65 participants were recorded during experiments that involved exposure to emotional stimuli (i.e., IAPS images, reading and writing messages on an artificial online discussion board). Temporal Taylor's fluctuations scaling were found when signals for various participants and during various types of emotional events were compared. Values of scaling exponents were close to 1, suggesting an external origin of system dynamics and/or strong interactions between system's basic elements (e.g., muscle fibres). Our statistical analysis shows that the scaling exponents enable identification of high valence and arousal levels in ZYG and COR signals.

  6. Simultaneous acquisition of corrugator electromyography and functional magnetic resonance imaging: A new method for objectively measuring affect and neural activity concurrently

    PubMed Central

    Heller, Aaron S.; Greischar, Lawrence L; Honor, Ann; Anderle, Michael J; Davidson, Richard J.

    2011-01-01

    The development of functional neuroimaging of emotion holds the promise to enhance our understanding of the biological bases of affect and improve our knowledge of psychiatric diseases. However, up to this point, researchers have been unable to objectively, continuously and unobtrusively measure the intensity and dynamics of affect concurrently with functional magnetic resonance imaging (fMRI). This has hindered the development and generalizability of our field. Facial electromyography (EMG) is an objective, reliable, valid, sensitive, and unobtrusive measure of emotion. Here, we report the successful development of a method for simultaneously acquiring fMRI and facial EMG. The ability to simultaneously acquire brain activity and facial physiology will allow affective neuroscientists to address theoretical, psychiatric, and individual difference questions in a more rigorous and generalizable way. PMID:21742043

  7. Facial EMG Responses to Emotional Expressions Are Related to Emotion Perception Ability

    PubMed Central

    Künecke, Janina; Hildebrandt, Andrea; Recio, Guillermo; Sommer, Werner; Wilhelm, Oliver

    2014-01-01

    Although most people can identify facial expressions of emotions well, they still differ in this ability. According to embodied simulation theories understanding emotions of others is fostered by involuntarily mimicking the perceived expressions, causing a “reactivation” of the corresponding mental state. Some studies suggest automatic facial mimicry during expression viewing; however, findings on the relationship between mimicry and emotion perception abilities are equivocal. The present study investigated individual differences in emotion perception and its relationship to facial muscle responses - recorded with electromyogram (EMG) - in response to emotional facial expressions. N° = °269 participants completed multiple tasks measuring face and emotion perception. EMG recordings were taken from a subsample (N° = °110) in an independent emotion classification task of short videos displaying six emotions. Confirmatory factor analyses of the m. corrugator supercilii in response to angry, happy, sad, and neutral expressions showed that individual differences in corrugator activity can be separated into a general response to all faces and an emotion-related response. Structural equation modeling revealed a substantial relationship between the emotion-related response and emotion perception ability, providing evidence for the role of facial muscle activation in emotion perception from an individual differences perspective. PMID:24489647

  8. When Age Matters: Differences in Facial Mimicry and Autonomic Responses to Peers' Emotions in Teenagers and Adults

    PubMed Central

    Ardizzi, Martina; Sestito, Mariateresa; Martini, Francesca; Umiltà, Maria Alessandra; Ravera, Roberto; Gallese, Vittorio

    2014-01-01

    Age-group membership effects on explicit emotional facial expressions recognition have been widely demonstrated. In this study we investigated whether Age-group membership could also affect implicit physiological responses, as facial mimicry and autonomic regulation, to observation of emotional facial expressions. To this aim, facial Electromyography (EMG) and Respiratory Sinus Arrhythmia (RSA) were recorded from teenager and adult participants during the observation of facial expressions performed by teenager and adult models. Results highlighted that teenagers exhibited greater facial EMG responses to peers' facial expressions, whereas adults showed higher RSA-responses to adult facial expressions. The different physiological modalities through which young and adults respond to peers' emotional expressions are likely to reflect two different ways to engage in social interactions with coetaneous. Findings confirmed that age is an important and powerful social feature that modulates interpersonal interactions by influencing low-level physiological responses. PMID:25337916

  9. Human facial neural activities and gesture recognition for machine-interfacing applications.

    PubMed

    Hamedi, M; Salleh, Sh-Hussain; Tan, T S; Ismail, K; Ali, J; Dee-Uam, C; Pavaganun, C; Yupapin, P P

    2011-01-01

    The authors present a new method of recognizing different human facial gestures through their neural activities and muscle movements, which can be used in machine-interfacing applications. Human-machine interface (HMI) technology utilizes human neural activities as input controllers for the machine. Recently, much work has been done on the specific application of facial electromyography (EMG)-based HMI, which have used limited and fixed numbers of facial gestures. In this work, a multipurpose interface is suggested that can support 2-11 control commands that can be applied to various HMI systems. The significance of this work is finding the most accurate facial gestures for any application with a maximum of eleven control commands. Eleven facial gesture EMGs are recorded from ten volunteers. Detected EMGs are passed through a band-pass filter and root mean square features are extracted. Various combinations of gestures with a different number of gestures in each group are made from the existing facial gestures. Finally, all combinations are trained and classified by a Fuzzy c-means classifier. In conclusion, combinations with the highest recognition accuracy in each group are chosen. An average accuracy >90% of chosen combinations proved their ability to be used as command controllers.

  10. Surface Electromyography Signal Processing and Classification Techniques

    PubMed Central

    Chowdhury, Rubana H.; Reaz, Mamun B. I.; Ali, Mohd Alauddin Bin Mohd; Bakar, Ashrif A. A.; Chellappan, Kalaivani; Chang, Tae. G.

    2013-01-01

    Electromyography (EMG) signals are becoming increasingly important in many applications, including clinical/biomedical, prosthesis or rehabilitation devices, human machine interactions, and more. However, noisy EMG signals are the major hurdles to be overcome in order to achieve improved performance in the above applications. Detection, processing and classification analysis in electromyography (EMG) is very desirable because it allows a more standardized and precise evaluation of the neurophysiological, rehabitational and assistive technological findings. This paper reviews two prominent areas; first: the pre-processing method for eliminating possible artifacts via appropriate preparation at the time of recording EMG signals, and second: a brief explanation of the different methods for processing and classifying EMG signals. This study then compares the numerous methods of analyzing EMG signals, in terms of their performance. The crux of this paper is to review the most recent developments and research studies related to the issues mentioned above. PMID:24048337

  11. Does Facial Amimia Impact the Recognition of Facial Emotions? An EMG Study in Parkinson’s Disease

    PubMed Central

    Argaud, Soizic; Delplanque, Sylvain; Houvenaghel, Jean-François; Auffret, Manon; Duprez, Joan; Vérin, Marc; Grandjean, Didier; Sauleau, Paul

    2016-01-01

    According to embodied simulation theory, understanding other people’s emotions is fostered by facial mimicry. However, studies assessing the effect of facial mimicry on the recognition of emotion are still controversial. In Parkinson’s disease (PD), one of the most distinctive clinical features is facial amimia, a reduction in facial expressiveness, but patients also show emotional disturbances. The present study used the pathological model of PD to examine the role of facial mimicry on emotion recognition by investigating EMG responses in PD patients during a facial emotion recognition task (anger, joy, neutral). Our results evidenced a significant decrease in facial mimicry for joy in PD, essentially linked to the absence of reaction of the zygomaticus major and the orbicularis oculi muscles in response to happy avatars, whereas facial mimicry for expressions of anger was relatively preserved. We also confirmed that PD patients were less accurate in recognizing positive and neutral facial expressions and highlighted a beneficial effect of facial mimicry on the recognition of emotion. We thus provide additional arguments for embodied simulation theory suggesting that facial mimicry is a potential lever for therapeutic actions in PD even if it seems not to be necessarily required in recognizing emotion as such. PMID:27467393

  12. Usefulness of electromyography of the cavernous corpora (CC EMG) in the diagnosis of arterial erectile dysfunction.

    PubMed

    Virseda-Chamorro, M; Lopez-Garcia-Moreno, A M; Salinas-Casado, J; Esteban-Fuertes, M

    2012-01-01

    Electromyography (EMG) of the corpora cavernosa (CC-EMG) is able to record the activity of the erectile tissue during erection, and thus has been used as a diagnostic technique in patients with erectile dysfunction (ED). The present study examines the usefulness of the technique in the diagnosis of arterial ED. A cross-sectional study was made of 35 males with a mean age of 48.5 years (s.d. 11.34), referred to our center with ED for >1 year. The patients were subjected to CC-EMG and a penile Doppler ultrasound study following the injection of 20 μg of prostaglandin E1 (PGE1). The patients were divided into three groups according to their response to the intracavernous injection of PGE1: Group 1 (adequate erection and reduction/suppression of EMG activity); Group 2 (insufficient erection and persistence of EMG activity); and Group 3 (insufficient erection and reduction/suppression of EMG activity). Patient classification according to response to the intracavernous injection of PGE1 was as follows: Group 1: six patients (17%), Group 2: 18 patients (51%), and Group 3: 11 patients (31%). Patients diagnosed with arterial insufficiency according to Doppler ultrasound (systolic arterial peak velocity <30 mm s(-1) in both arteries) were significantly older than those without such damage (54.5 versus 41.8 years, respectively; s.d. 11.12). The patients in Group 3 showed a significantly lower maximum systolic velocity in both arteries than the subjects belonging to Group 2. Likewise, a statistically significant relationship was observed between the diagnosis of arterial insufficiency and patient classification in Group 3. The confirmation of insufficient erection associated with reduction/suppression of EMG activity showed a sensitivity of 66.7% (confidence interval between 50 and 84%) and a specificity of 92.9% (confidence interval between 84 and 100%) in the diagnosis of arterial ED. Owing to the high specificity of CC-EMG response to the injection of PGE1, this test is

  13. Embodied simulation as part of affective evaluation processes: task dependence of valence concordant EMG activity.

    PubMed

    Weinreich, André; Funcke, Jakob Maria

    2014-01-01

    Drawing on recent findings, this study examines whether valence concordant electromyography (EMG) responses can be explained as an unconditional effect of mere stimulus processing or as somatosensory simulation driven by task-dependent processing strategies. While facial EMG over the Corrugator supercilii and the Zygomaticus major was measured, each participant performed two tasks with pictures of album covers. One task was an affective evaluation task and the other was to attribute the album covers to one of five decades. The Embodied Emotion Account predicts that valence concordant EMG is more likely to occur if the task necessitates a somatosensory simulation of the evaluative meaning of stimuli. Results support this prediction with regard to Corrugator supercilii in that valence concordant EMG activity was only present in the affective evaluation task but not in the non-evaluative task. Results for the Zygomaticus major were ambiguous. Our findings are in line with the view that EMG activity is an embodied part of the evaluation process and not a mere physical outcome.

  14. Outcome-dependent coactivation of lip and tongue primary somatosensory representation following hypoglossal-facial transfer after peripheral facial palsy.

    PubMed

    Rottler, Philipp; Schroeder, Henry W S; Lotze, Martin

    2014-02-01

    A hypoglossal-facial transfer is a common surgical strategy for reanimating the face after persistent total hemifacial palsy. We were interested in how motor recovery is associated with cortical reorganization of lip and tongue representation in the primary sensorimotor cortex after the transfer. Therefore, we used functional magnetic resonance imaging (fMRI) in 13 patients who underwent a hypoglossal-facial transfer after unilateral peripheral facial palsy. To identify primary motor and somatosensory tongue and lip representation sites, we measured repetitive tongue and lip movements during fMRI. Electromyography (EMG) of the perioral muscles during tongue and lip movements and standardized evaluation of lip elevation served as outcome parameters. We found an association of cortical representation sites in the pre- and postcentral gyrus (decreased distance of lip and tongue representation) with symmetry of recovered lip movements (lip elevation) and coactivation of the lip during voluntary tongue movements (EMG-activity of the lip during tongue movements). Overall, our study shows that hypoglossal-facial transfer resulted in an outcome-dependent cortical reorganization with activation of the cortical tongue area for restituded movement of the lip. Copyright © 2012 Wiley Periodicals, Inc.

  15. [Integration of the functional signal of intraoperative EMG of the facial nerve in to navigation model for surgery of the petrous bone].

    PubMed

    Strauss, G; Strauss, M; Lüders, C; Stopp, S; Shi, J; Dietz, A; Lüth, T

    2008-10-01

    PROBLEM DEFINITION: The goal of this work is the integration of the information of the intraoperative EMG monitoring of the facial nerve into the radiological data of the petrous bone. The following hypotheses are to be examined: (I) the N. VII can be determined intraoperatively with a high reliability by the stimulation-probe. A computer program is able to discriminate true-positive EMG signals from false-positive artifacts. (II) The course of the facial nerve can be registered in a three-dimensional area by EMG signals at a nerve model in the lab test. The individual items of the nerve can be combined into a route model. The route model can be integrated into the data of digital volume tomography (DVT). (I) Intraoperative EMG signals of the facial nerve were classified at 128 measurements by an automatic software. The results were correlated with the actual intraoperative situation. (II) The nerve phantom was designed and a DVT data set was provided. Phantom was registered with a navigation system (Karl Storz NPU, Tuttlingen, Germany). The stimulation probe of the EMG-system was tracked by the navigation system. The navigation system was extended by a processing unit (MiMed, Technische Universität München, Germany). Thus the classified EMG parameters of the facial route can be received, processed and be generated to a model of the facial nerve route. The operability was examined at 120 (10 x 12) measuring points. The evaluation of the examined algorithm for classification EMG-signals of the facial nerve resulted as correct in all measuring events. In all 10 attempts it succeeded to visualize the nerve route as three-dimensional model. The different sizes of the individual measuring points reflect the appropriate values of Istim and UEMG correctly. This work proves the feasibility of an automatic classification of an intraoperative EMG signal of the facial nerve by a processing unit. Furthermore the work shows the feasibility of tracking of the position of the

  16. Enjoying vs. smiling: Facial muscular activation in response to emotional language.

    PubMed

    Fino, Edita; Menegatti, Michela; Avenanti, Alessio; Rubini, Monica

    2016-07-01

    The present study examined whether emotionally congruent facial muscular activation - a somatic index of emotional language embodiment can be elicited by reading subject-verb sentences composed of action verbs, that refer directly to facial expressions (e.g., Mario smiles), but also by reading more abstract state verbs, which provide more direct access to the emotions felt by the agent (e.g., Mario enjoys). To address this issue, we measured facial electromyography (EMG) while participants evaluated state and action verb sentences. We found emotional sentences including both verb categories to have valence-congruent effects on emotional ratings and corresponding facial muscle activations. As expected, state verb-sentences were judged with higher valence ratings than action verb-sentences. Moreover, despite emotional congruent facial activations were similar for the two linguistic categories, in a late temporal window we found a tendency for greater EMG modulation when reading action relative to state verb sentences. These results support embodied theories of language comprehension and suggest that understanding emotional action and state verb sentences relies on partially dissociable motor and emotional processes. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Entropy of electromyography time series

    NASA Astrophysics Data System (ADS)

    Kaufman, Miron; Zurcher, Ulrich; Sung, Paul S.

    2007-12-01

    A nonlinear analysis based on Renyi entropy is applied to electromyography (EMG) time series from back muscles. The time dependence of the entropy of the EMG signal exhibits a crossover from a subdiffusive regime at short times to a plateau at longer times. We argue that this behavior characterizes complex biological systems. The plateau value of the entropy can be used to differentiate between healthy and low back pain individuals.

  18. Emg Signal Analysis of Healthy and Neuropathic Individuals

    NASA Astrophysics Data System (ADS)

    Gupta, Ashutosh; Sayed, Tabassum; Garg, Ridhi; Shreyam, Richa

    2017-08-01

    Electromyography is a method to evaluate levels of muscle activity. When a muscle contracts, an action potential is generated and this circulates along the muscular fibers. In electromyography, electrodes are connected to the skin and the electrical activity of muscles is measured and graph is plotted. The surface EMG signals picked up during the muscular activity are interfaced with a system. The EMG signals from individual suffering from Neuropathy and healthy individual, so obtained, are processed and analyzed using signal processing techniques. This project includes the investigation and interpretation of EMG signals of healthy and Neuropathic individuals using MATLAB. The prospective use of this study is in developing the prosthetic device for the people with Neuropathic disability.

  19. Simultaneous Scalp Electroencephalography (EEG), Electromyography (EMG), and Whole-body Segmental Inertial Recording for Multi-modal Neural Decoding

    PubMed Central

    Bulea, Thomas C.; Kilicarslan, Atilla; Ozdemir, Recep; Paloski, William H.; Contreras-Vidal, Jose L.

    2013-01-01

    Recent studies support the involvement of supraspinal networks in control of bipedal human walking. Part of this evidence encompasses studies, including our previous work, demonstrating that gait kinematics and limb coordination during treadmill walking can be inferred from the scalp electroencephalogram (EEG) with reasonably high decoding accuracies. These results provide impetus for development of non-invasive brain-machine-interface (BMI) systems for use in restoration and/or augmentation of gait- a primary goal of rehabilitation research. To date, studies examining EEG decoding of activity during gait have been limited to treadmill walking in a controlled environment. However, to be practically viable a BMI system must be applicable for use in everyday locomotor tasks such as over ground walking and turning. Here, we present a novel protocol for non-invasive collection of brain activity (EEG), muscle activity (electromyography (EMG)), and whole-body kinematic data (head, torso, and limb trajectories) during both treadmill and over ground walking tasks. By collecting these data in the uncontrolled environment insight can be gained regarding the feasibility of decoding unconstrained gait and surface EMG from scalp EEG. PMID:23912203

  20. Simultaneous scalp electroencephalography (EEG), electromyography (EMG), and whole-body segmental inertial recording for multi-modal neural decoding.

    PubMed

    Bulea, Thomas C; Kilicarslan, Atilla; Ozdemir, Recep; Paloski, William H; Contreras-Vidal, Jose L

    2013-07-26

    Recent studies support the involvement of supraspinal networks in control of bipedal human walking. Part of this evidence encompasses studies, including our previous work, demonstrating that gait kinematics and limb coordination during treadmill walking can be inferred from the scalp electroencephalogram (EEG) with reasonably high decoding accuracies. These results provide impetus for development of non-invasive brain-machine-interface (BMI) systems for use in restoration and/or augmentation of gait- a primary goal of rehabilitation research. To date, studies examining EEG decoding of activity during gait have been limited to treadmill walking in a controlled environment. However, to be practically viable a BMI system must be applicable for use in everyday locomotor tasks such as over ground walking and turning. Here, we present a novel protocol for non-invasive collection of brain activity (EEG), muscle activity (electromyography (EMG)), and whole-body kinematic data (head, torso, and limb trajectories) during both treadmill and over ground walking tasks. By collecting these data in the uncontrolled environment insight can be gained regarding the feasibility of decoding unconstrained gait and surface EMG from scalp EEG.

  1. Entropic Analysis of Electromyography Time Series

    NASA Astrophysics Data System (ADS)

    Kaufman, Miron; Sung, Paul

    2005-03-01

    We are in the process of assessing the effectiveness of fractal and entropic measures for the diagnostic of low back pain from surface electromyography (EMG) time series. Surface electromyography (EMG) is used to assess patients with low back pain. In a typical EMG measurement, the voltage is measured every millisecond. We observed back muscle fatiguing during one minute, which results in a time series with 60,000 entries. We characterize the complexity of time series by computing the Shannon entropy time dependence. The analysis of the time series from different relevant muscles from healthy and low back pain (LBP) individuals provides evidence that the level of variability of back muscle activities is much larger for healthy individuals than for individuals with LBP. In general the time dependence of the entropy shows a crossover from a diffusive regime to a regime characterized by long time correlations (self organization) at about 0.01s.

  2. The effects of post-stroke upper-limb training with an electromyography (EMG)-driven hand robot.

    PubMed

    Hu, X L; Tong, K Y; Wei, X J; Rong, W; Susanto, E A; Ho, S K

    2013-10-01

    Loss of hand function and finger dexterity are main disabilities in the upper limb after stroke. An electromyography (EMG)-driven hand robot had been developed for post-stroke rehabilitation training. The effectiveness of the hand robot assisted whole upper limb training was investigated on persons with chronic stroke (n=10) in this work. All subjects attended a 20-session training (3-5times/week) by using the hand robot to practice object grasp/release and arm transportation tasks. Significant motor improvements were observed in the Fugl-Meyer hand/wrist and shoulder/elbow scores (p<0.05), and also in the Action Research Arm Test and Wolf Motor Function Test (p<0.05). Significant reduction in spasticity of the fingers as was measured by the Modified Ashworth Score (p<0.05). The training improved the muscle co-ordination between the antagonist muscle pair (flexor digitorum (FD) and extensor digitorum (ED)), associated with a significant reduction in the ED EMG level (p<0.05) and a significant decrease of ED and FD co-contraction during the training (p<0.05); the excessive muscle activities in the biceps brachii were also reduced significantly after the training (p<0.05). Copyright © 2013 Elsevier Ltd. All rights reserved.

  3. Recovery of facial expressions using functional electrical stimulation after full-face transplantation.

    PubMed

    Topçu, Çağdaş; Uysal, Hilmi; Özkan, Ömer; Özkan, Özlenen; Polat, Övünç; Bedeloğlu, Merve; Akgül, Arzu; Döğer, Ela Naz; Sever, Refik; Çolak, Ömer Halil

    2018-03-06

    We assessed the recovery of 2 face transplantation patients with measures of complexity during neuromuscular rehabilitation. Cognitive rehabilitation methods and functional electrical stimulation were used to improve facial emotional expressions of full-face transplantation patients for 5 months. Rehabilitation and analyses were conducted at approximately 3 years after full facial transplantation in the patient group. We report complexity analysis of surface electromyography signals of these two patients in comparison to the results of 10 healthy individuals. Facial surface electromyography data were collected during 6 basic emotional expressions and 4 primary facial movements from 2 full-face transplantation patients and 10 healthy individuals to determine a strategy of functional electrical stimulation and understand the mechanisms of rehabilitation. A new personalized rehabilitation technique was developed using the wavelet packet method. Rehabilitation sessions were applied twice a month for 5 months. Subsequently, motor and functional progress was assessed by comparing the fuzzy entropy of surface electromyography data against the results obtained from patients before rehabilitation and the mean results obtained from 10 healthy subjects. At the end of personalized rehabilitation, the patient group showed improvements in their facial symmetry and their ability to perform basic facial expressions and primary facial movements. Similarity in the pattern of fuzzy entropy for facial expressions between the patient group and healthy individuals increased. Synkinesis was detected during primary facial movements in the patient group, and one patient showed synkinesis during the happiness expression. Synkinesis in the lower face region of one of the patients was eliminated for the lid tightening movement. The recovery of emotional expressions after personalized rehabilitation was satisfactory to the patients. The assessment with complexity analysis of sEMG data can be

  4. Reduced facial reactivity as a contributor to preserved emotion regulation in older adults.

    PubMed

    Pedder, David J; Terrett, Gill; Bailey, Phoebe E; Henry, Julie D; Ruffman, Ted; Rendell, Peter G

    2016-02-01

    This study investigated whether differences in the type of strategy used, or age-related differences in intensity of facial reactivity, might contribute to preserved emotion regulation ability in older adults. Young (n = 35) and older (n = 33) adults were instructed to regulate their emotion to positive and negative pictures under 3 conditions (watch, expressive suppression, cognitive 'detached' reappraisal). Participants were objectively monitored using facial electromyography (EMG) and assessed on memory performance. Both age groups were effectively, and equivalently, able to reduce their facial expressions. In relation to facial reactivity, the percentage increase of older adults' facial muscle EMG activity in the watch condition was significantly reduced relative to young adults. Recall of pictures following regulation was similar to the watch condition, and there was no difference in memory performance between the 2 regulation strategies for both groups. These findings do not support the proposal that the type of strategy used explains preserved emotion regulation ability in older adults. Coupled with the lack of memory costs following regulation, these data instead are more consistent with the suggestion that older adults may retain emotion regulation capacity partly because they exhibit less facial reactivity to begin with. (c) 2016 APA, all rights reserved).

  5. Electromyography (EMG) analysis on impact of classroom chair and table usage among primary school students in Perlis

    NASA Astrophysics Data System (ADS)

    Jing, Ewe Hui; Shan, Lim Shaiu; Effendi, M. S. M.; Rosli, Muhamad Farizuan

    2017-09-01

    The existing design of primary school classroom chair and table had brought low back pain, neck pain and shoulder pain problems respectively among students in primary school. The purpose of this study is to relate the electromyography (EMG) analysis with the most critical area of the body during sitting and writing. Six male and six female primary school students from SK Seri Perlis with no back pain, neck pain and shoulder pain problems involved were invited as respondents in this study. EMG experiment was carried out by first determined the critical point at T9 and L3 from thoracic and lumbar segment respectively for ECG electrode placement and performed with a series of sitting trials for analysis. The sitting trials performed were slouch to lumbopelvic sitting and slouch to thoracic sitting follow by instruction. Next, the electrode placement was identified at C2-C3 on cervical spine for neck and at midpoint between C7 to the lateral edge of acromion spanning for shoulder respectively. These points were identified for a series of writing task performing for the EMG analysis. There were two type of writing task which included writing by looking at the whiteboard and paper placed on the table. The subjects were instructed to rest during the experiment when necessary. During lumbopelvic sitting posture, the average muscle activation on lumbar area was at the highest peak. The peak indicated that there was critical effect from the experimental finding. The performance of writing task from whiteboard gave rise a higher impact on neck muscle while writing task from paper had a greater impact on shoulder muscle. The critical affected muscle on these areas was proven on these written tasks. The EMG experiment showed that the existing design of primary school classroom chair and table had brought impact on lumbar, neck and shoulder towards the students who were using. A future recommendation suggests that to redesign primary school classroom chair and table which

  6. Surface Electromyography for Speech and Swallowing Systems: Measurement, Analysis, and Interpretation

    ERIC Educational Resources Information Center

    Stepp, Cara E.

    2012-01-01

    Purpose: Applying surface electromyography (sEMG) to the study of voice, speech, and swallowing is becoming increasingly popular. An improved understanding of sEMG and building a consensus as to appropriate methodology will improve future research and clinical applications. Method: An updated review of the theory behind recording sEMG for the…

  7. Rapid facial reactions to emotional facial expressions in typically developing children and children with autism spectrum disorder.

    PubMed

    Beall, Paula M; Moody, Eric J; McIntosh, Daniel N; Hepburn, Susan L; Reed, Catherine L

    2008-11-01

    Typical adults mimic facial expressions within 1000 ms, but adults with autism spectrum disorder (ASD) do not. These rapid facial reactions (RFRs) are associated with the development of social-emotional abilities. Such interpersonal matching may be caused by motor mirroring or emotional responses. Using facial electromyography (EMG), this study evaluated mechanisms underlying RFRs during childhood and examined possible impairment in children with ASD. Experiment 1 found RFRs to happy and angry faces (not fear faces) in 15 typically developing children from 7 to 12 years of age. RFRs of fear (not anger) in response to angry faces indicated an emotional mechanism. In 11 children (8-13 years of age) with ASD, Experiment 2 found undifferentiated RFRs to fear expressions and no consistent RFRs to happy or angry faces. However, as children with ASD aged, matching RFRs to happy faces increased significantly, suggesting the development of processes underlying matching RFRs during this period in ASD.

  8. Effects of touch on emotional face processing: A study of event-related potentials, facial EMG and cardiac activity.

    PubMed

    Spapé, M M; Harjunen, Ville; Ravaja, N

    2017-03-01

    Being touched is known to affect emotion, and even a casual touch can elicit positive feelings and affinity. Psychophysiological studies have recently shown that tactile primes affect visual evoked potentials to emotional stimuli, suggesting altered affective stimulus processing. As, however, these studies approached emotion from a purely unidimensional perspective, it remains unclear whether touch biases emotional evaluation or a more general feature such as salience. Here, we investigated how simple tactile primes modulate event related potentials (ERPs), facial EMG and cardiac response to pictures of facial expressions of emotion. All measures replicated known effects of emotional face processing: Disgust and fear modulated early ERPs, anger increased the cardiac orienting response, and expressions elicited emotion-congruent facial EMG activity. Tactile primes also affected these measures, but priming never interacted with the type of emotional expression. Thus, touch may additively affect general stimulus processing, but it does not bias or modulate immediate affective evaluation. Copyright © 2017. Published by Elsevier B.V.

  9. Influence of a scheduled-waiting task on EMG reactivity and oral habits among facial pain patients and no-pain controls.

    PubMed

    Nicholson, R A; Townsend, D R; Gramling, S E

    2000-12-01

    Recent research has strongly implicated the role of psychological stress in the development of temporomandibular disorders (TMD). It is widely reported that oral habits (e.g., teeth grinding) probably provide a behavioral link between stress and the development of TMD symptomatology. Extrapolation of research in the field of adjunctive behavior to the TMD disorders suggests that oral behaviors may develop conjointly with fixed-time (FT) stimulus presentation. The current experiment extended previous research examining this possibility by assessing the influence of experimental stress on masseter EMG and oral habits among persons who met broadband criteria for TMD and no-pain controls. Oral habit activity was assessed via self-report questionnaire whereas masseter muscle activity was measured continuously via electromyography across four phases (Adaptation, Free-Play, Scheduled-Play, Recovery). The Scheduled-Play phase was designed as a stress-reactivity task that included an FT schedule. Results indicated that, consistent with the stress-reactivity model, the Scheduled-Play phase resulted in a significant increase in masseter EMG levels relative to Free-Play and Adaptation, and that this effect was significantly larger for the TMD group relative to controls. The results suggest an adjunctive behavior effect although the effect was not specific to those with facial pain. Oral habit data showed a significant phase effect with oral habits that was significantly higher during the Scheduled-Play phase relative to Adaptation. The findings are the impetus for further study regarding the mechanisms whereby oral habits are developed and maintained despite their painful consequences.

  10. Schedule-induced masseter EMG in facial pain subjects vs. no-pain controls.

    PubMed

    Gramling, S E; Grayson, R L; Sullivan, T N; Schwartz, S

    1997-02-01

    Empirical reports suggest that oral habits (e.g., teeth clenching) may be behavioral mediators linking stress to muscle hyperreactivity and the development of facial pain. Another report suggests that excessive behavioral adjuncts develop in conjunction with fixed-time stimulus presentation. The present study assessed the extent to which the oral habits exhibited by facial pain patients are schedule-induced. Subjects with Temporomandibular Disorder (TMD) symptomatology (n = 15) and pain-free controls (n = 15) participated in a 4-phase experiment (adaptation, baseline, task, recovery) designed to elicit schedule-induced behaviors. Self-report of oral habits and negative affect were recorded after each phase. Objective measures of oral habits were obtained via behavioral observation and masseter EMG recordings. Results revealed that negative arousal significantly increased during the fixed-time (FT) task and was also associated with increased oral habits among the TMD subjects. Moreover, 40% of the TMD subjects and none of the controls exhibited a pattern of EMG elevations in the early part of the inter-stimulus interval that met a strict criteria for scheduled-induced behavior per se. Taken together, these results suggest that the TMD subjects were engaging in schedule-induced oral habits. The adjunctive behavior literature seems to provide a plausible explanation as to how oral habits develop and are maintained in TMD patients, despite their painful consequences.

  11. Electromyographic analysis of the masseter and buccinator muscles with the pro-fono facial exerciser use in bruxers.

    PubMed

    Jardini, Renata S R; Ruiz, Lydia S R; Moysés, Maria A A

    2006-01-01

    The aim of this study was to evaluate the efficiency of the Pró-Fono Facial Exerciser (Pró-Fono Productos Especializados para Fonoaudiologia Ltda., Barueri/SP, Brazil) to decrease bruxism, as well as the correlation between the masseter and the buccinator muscles using electromyography (EMG). In this study, 39 individuals ranging from 23 to 48 years of age were selected from a dental school and then underwent surface EMG at three different periods of time: 0, 10, and 70 days. They were divided into a normal control group, a bruxer control group (without device), and an experimental bruxer group who used the device. The bruxer group showed a greater masseter EMG amplitude when compared to the normal group, while the experimental group had deceased activity with a reduction in symptoms. The buccinator EMG spectral analysis of the experimental bruxist group showed asynchronous contractions of the masseter muscle (during jaw opening) after using the Pró-Fono Facial Exerciser. The normal group also showed asynchronous contractions. Upon correlation of the data between these muscles, the inference is that there is a reduction in bruxism when activating the buccinator muscle.

  12. The risk of iatrogenic pneumothorax after electromyography.

    PubMed

    Kassardjian, Charles D; O'gorman, Cullen M; Sorenson, Eric J

    2016-04-01

    Pneumothorax is a potentially serious complication of electromyography (EMG). Data on the frequency of pneumothorax after EMG are lacking. The purpose of this study was to determine the frequency, timing, and risk factors for iatrogenic pneumothorax after EMG. Cases of pneumothorax after EMG were reviewed for clinical, electrophysiological, and radiological data. Of 64,490 EMG studies, 7 patients had an association between the EMG and pneumothorax. All patients were symptomatic and presented within 24 hours of EMG. Sampling of serratus anterior and diaphragm was causative in 1 patient each. In 5 patients, multiple high-risk muscles were sampled. The highest frequency of pneumothorax was observed with examination of serratus anterior (0.445%) and diaphragm (0.149%). The frequency of symptomatic iatrogenic pneumothorax after EMG appears to be low, and examinations of serratus anterior and diaphragm carry the highest risk. Electromyographers should be aware of the risk of pneumothorax and should counsel patients accordingly. © 2015 Wiley Periodicals, Inc.

  13. Objectifying Facial Expressivity Assessment of Parkinson's Patients: Preliminary Study

    PubMed Central

    Patsis, Georgios; Jiang, Dongmei; Sahli, Hichem; Kerckhofs, Eric; Vandekerckhove, Marie

    2014-01-01

    Patients with Parkinson's disease (PD) can exhibit a reduction of spontaneous facial expression, designated as “facial masking,” a symptom in which facial muscles become rigid. To improve clinical assessment of facial expressivity of PD, this work attempts to quantify the dynamic facial expressivity (facial activity) of PD by automatically recognizing facial action units (AUs) and estimating their intensity. Spontaneous facial expressivity was assessed by comparing 7 PD patients with 8 control participants. To voluntarily produce spontaneous facial expressions that resemble those typically triggered by emotions, six emotions (amusement, sadness, anger, disgust, surprise, and fear) were elicited using movie clips. During the movie clips, physiological signals (facial electromyography (EMG) and electrocardiogram (ECG)) and frontal face video of the participants were recorded. The participants were asked to report on their emotional states throughout the experiment. We first examined the effectiveness of the emotion manipulation by evaluating the participant's self-reports. Disgust-induced emotions were significantly higher than the other emotions. Thus we focused on the analysis of the recorded data during watching disgust movie clips. The proposed facial expressivity assessment approach captured differences in facial expressivity between PD patients and controls. Also differences between PD patients with different progression of Parkinson's disease have been observed. PMID:25478003

  14. Objectifying facial expressivity assessment of Parkinson's patients: preliminary study.

    PubMed

    Wu, Peng; Gonzalez, Isabel; Patsis, Georgios; Jiang, Dongmei; Sahli, Hichem; Kerckhofs, Eric; Vandekerckhove, Marie

    2014-01-01

    Patients with Parkinson's disease (PD) can exhibit a reduction of spontaneous facial expression, designated as "facial masking," a symptom in which facial muscles become rigid. To improve clinical assessment of facial expressivity of PD, this work attempts to quantify the dynamic facial expressivity (facial activity) of PD by automatically recognizing facial action units (AUs) and estimating their intensity. Spontaneous facial expressivity was assessed by comparing 7 PD patients with 8 control participants. To voluntarily produce spontaneous facial expressions that resemble those typically triggered by emotions, six emotions (amusement, sadness, anger, disgust, surprise, and fear) were elicited using movie clips. During the movie clips, physiological signals (facial electromyography (EMG) and electrocardiogram (ECG)) and frontal face video of the participants were recorded. The participants were asked to report on their emotional states throughout the experiment. We first examined the effectiveness of the emotion manipulation by evaluating the participant's self-reports. Disgust-induced emotions were significantly higher than the other emotions. Thus we focused on the analysis of the recorded data during watching disgust movie clips. The proposed facial expressivity assessment approach captured differences in facial expressivity between PD patients and controls. Also differences between PD patients with different progression of Parkinson's disease have been observed.

  15. Evoked electromyography to rocuronium in orbicularis oris and gastrocnemius in facial nerve injury in rabbits.

    PubMed

    Xing, Yian; Chen, Lianhua; Li, Shitong

    2013-11-01

    Muscles innervated by the facial nerve show different sensitivities to muscle relaxants than muscles innervated by somatic nerves, especially in the presence of facial nerve injury. We compared the evoked electromyography (EEMG) response of orbicularis oris and gastrocnemius in with and without a non-depolarizing muscle relaxant in a rabbit model of graded facial nerve injury. Differences in EEMG response and inhibition by rocuronium were measured in the orbicularis oris and gastrocnemius muscles 7 to 42 d after different levels of facial nerve crush injuries in adult rabbits. Baseline EEMG of orbicularis oris was significantly smaller than those of the gastrocnemius. Gastrocnemius was more sensitive to rocuronium than the facial muscles (P < 0.05). Baseline EEMG and EEMG amplitude of orbicularis oris in the presence of rocuronium was negatively correlated with the magnitude of facial nerve injury but the sensitivity to rocuronium was not. No significant difference was found in the onset time and the recovery time of rocuronium among gastrocnemius and normal or damaged facial muscles. Muscles innervated by somatic nerves are more sensitive to rocuronium than those innervated by the facial nerve, but while facial nerve injury reduced EEMG responses, the sensitivity to rocuronium is not altered. Partial neuromuscular blockade may be a suitable technique for conducting anesthesia and surgery safely when EEMG monitoring is needed to preserve and protect the facial nerve. Additional caution should be used if there is a risk of preexisting facial nerve injury. Copyright © 2013 Elsevier Inc. All rights reserved.

  16. Agonist and Antagonist Muscle EMG Activity Pattern Changes with Skill Acquisition.

    ERIC Educational Resources Information Center

    Engelhorn, Richard

    1983-01-01

    Using electromyography (EMG), researchers studied changes in the control of biceps and triceps brachii muscles that occurred as women college students learned two elbow flexion tasks. Data on EMG activity, angular kinematics, training, and angular displacement were analyzed. (Author/PP)

  17. Corticospinal excitability measurements using transcranial magnetic stimulation are valid with intramuscular electromyography

    PubMed Central

    2017-01-01

    Objectives Muscular targets that are deep or inaccessible to surface electromyography (sEMG) require intrinsic recording using fine-wire electromyography (fEMG). It is unknown if fEMG validly record cortically evoked muscle responses compared to sEMG. The purpose of this investigation was to establish the validity and agreement of fEMG compared to sEMG to quantify typical transcranial magnetic stimulation (TMS) measures pre and post repetitive TMS (rTMS). The hypotheses were that fEMG would demonstrate excellent validity and agreement compared with sEMG. Materials and methods In ten healthy volunteers, paired pulse and cortical silent period (CSP) TMS measures were collected before and after 1200 pulses of 1Hz rTMS to the motor cortex. Data were simultaneously recorded with sEMG and fEMG in the first dorsal interosseous. Concurrent validity (r and rho) and agreement (Tukey mean-difference) were calculated. Results fEMG quantified corticospinal excitability with good to excellent validity compared to sEMG data at both pretest (r = 0.77–0.97) and posttest (r = 0.83–0.92). Pairwise comparisons indicated no difference between sEMG and fEMG for all outcomes; however, Tukey mean-difference plots display increased variance and questionable agreement for paired pulse outcomes. CSP displayed the highest estimates of validity and agreement. Paired pulse MEP responses recorded with fEMG displayed reduced validity, agreement and less sensitivity to changes in MEP amplitude compared to sEMG. Change scores following rTMS were not significantly different between sEMG and fEMG. Conclusion fEMG electrodes are a valid means to measure CSP and paired pulse MEP responses. CSP displays the highest validity estimates, while caution is warranted when assessing paired pulse responses with fEMG. Corticospinal excitability and neuromodulatory aftereffects from rTMS may be assessed using fEMG. PMID:28231250

  18. Corticospinal excitability measurements using transcranial magnetic stimulation are valid with intramuscular electromyography.

    PubMed

    Summers, Rebekah L S; Chen, Mo; Kimberley, Teresa J

    2017-01-01

    Muscular targets that are deep or inaccessible to surface electromyography (sEMG) require intrinsic recording using fine-wire electromyography (fEMG). It is unknown if fEMG validly record cortically evoked muscle responses compared to sEMG. The purpose of this investigation was to establish the validity and agreement of fEMG compared to sEMG to quantify typical transcranial magnetic stimulation (TMS) measures pre and post repetitive TMS (rTMS). The hypotheses were that fEMG would demonstrate excellent validity and agreement compared with sEMG. In ten healthy volunteers, paired pulse and cortical silent period (CSP) TMS measures were collected before and after 1200 pulses of 1Hz rTMS to the motor cortex. Data were simultaneously recorded with sEMG and fEMG in the first dorsal interosseous. Concurrent validity (r and rho) and agreement (Tukey mean-difference) were calculated. fEMG quantified corticospinal excitability with good to excellent validity compared to sEMG data at both pretest (r = 0.77-0.97) and posttest (r = 0.83-0.92). Pairwise comparisons indicated no difference between sEMG and fEMG for all outcomes; however, Tukey mean-difference plots display increased variance and questionable agreement for paired pulse outcomes. CSP displayed the highest estimates of validity and agreement. Paired pulse MEP responses recorded with fEMG displayed reduced validity, agreement and less sensitivity to changes in MEP amplitude compared to sEMG. Change scores following rTMS were not significantly different between sEMG and fEMG. fEMG electrodes are a valid means to measure CSP and paired pulse MEP responses. CSP displays the highest validity estimates, while caution is warranted when assessing paired pulse responses with fEMG. Corticospinal excitability and neuromodulatory aftereffects from rTMS may be assessed using fEMG.

  19. Investigation of Physiological Properties of Nerves and Muscles Using Electromyography

    ERIC Educational Resources Information Center

    Roe, Seán M.; Johnson, Christopher D.; Tansey, Etain A.

    2014-01-01

    The measurement and representation of the electrical activity of muscles [electromyography (EMG)] have a long history from the Victorian Era until today. Currently, EMG has uses both as a research tool, in noninvasively recording muscle activation, and clinically in the diagnosis and assessment of nerve and muscle disease and injury as well as in…

  20. Beauty in the eye of the beholder: Using facial electromyography to examine the association between eating disorder symptoms and perceptions of emaciation among undergraduate women.

    PubMed

    Dodd, Dorian R; Velkoff, Elizabeth A; Forrest, Lauren N; Fussner, Lauren M; Smith, April

    2017-06-01

    Thin-ideal internalization, drive for thinness, and over-evaluation of the importance of thinness are associated with eating disorders (EDs). However, little research has examined to what extent perceptions of emaciation are also associated with ED symptoms. In the present study, 80 undergraduate women self-reported on ED symptomatology and perceptions of emaciated, thin, and overweight female bodies. While participants viewed images of these different body types, facial electromyography was used to measure activation of facial muscles associated with disgust reactions. Emaciated and overweight bodies were rated negatively and elicited facial responses consistent with disgust. Further, ED symptomatology was associated with pronounced aversion to overweight bodies (assessed via self-report pleasantness ratings), and attenuated negative affect to emaciated bodies (assessed via facial electromyography). The latter association was significant even when controlling for self-reported perceptions of emaciation, suggesting that psychophysiological methods in ED research may provide valuable information unavailable via self-report. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Incongruence Between Observers’ and Observed Facial Muscle Activation Reduces Recognition of Emotional Facial Expressions From Video Stimuli

    PubMed Central

    Wingenbach, Tanja S. H.; Brosnan, Mark; Pfaltz, Monique C.; Plichta, Michael M.; Ashwin, Chris

    2018-01-01

    According to embodied cognition accounts, viewing others’ facial emotion can elicit the respective emotion representation in observers which entails simulations of sensory, motor, and contextual experiences. In line with that, published research found viewing others’ facial emotion to elicit automatic matched facial muscle activation, which was further found to facilitate emotion recognition. Perhaps making congruent facial muscle activity explicit produces an even greater recognition advantage. If there is conflicting sensory information, i.e., incongruent facial muscle activity, this might impede recognition. The effects of actively manipulating facial muscle activity on facial emotion recognition from videos were investigated across three experimental conditions: (a) explicit imitation of viewed facial emotional expressions (stimulus-congruent condition), (b) pen-holding with the lips (stimulus-incongruent condition), and (c) passive viewing (control condition). It was hypothesised that (1) experimental condition (a) and (b) result in greater facial muscle activity than (c), (2) experimental condition (a) increases emotion recognition accuracy from others’ faces compared to (c), (3) experimental condition (b) lowers recognition accuracy for expressions with a salient facial feature in the lower, but not the upper face area, compared to (c). Participants (42 males, 42 females) underwent a facial emotion recognition experiment (ADFES-BIV) while electromyography (EMG) was recorded from five facial muscle sites. The experimental conditions’ order was counter-balanced. Pen-holding caused stimulus-incongruent facial muscle activity for expressions with facial feature saliency in the lower face region, which reduced recognition of lower face region emotions. Explicit imitation caused stimulus-congruent facial muscle activity without modulating recognition. Methodological implications are discussed. PMID:29928240

  2. Incongruence Between Observers' and Observed Facial Muscle Activation Reduces Recognition of Emotional Facial Expressions From Video Stimuli.

    PubMed

    Wingenbach, Tanja S H; Brosnan, Mark; Pfaltz, Monique C; Plichta, Michael M; Ashwin, Chris

    2018-01-01

    According to embodied cognition accounts, viewing others' facial emotion can elicit the respective emotion representation in observers which entails simulations of sensory, motor, and contextual experiences. In line with that, published research found viewing others' facial emotion to elicit automatic matched facial muscle activation, which was further found to facilitate emotion recognition. Perhaps making congruent facial muscle activity explicit produces an even greater recognition advantage. If there is conflicting sensory information, i.e., incongruent facial muscle activity, this might impede recognition. The effects of actively manipulating facial muscle activity on facial emotion recognition from videos were investigated across three experimental conditions: (a) explicit imitation of viewed facial emotional expressions (stimulus-congruent condition), (b) pen-holding with the lips (stimulus-incongruent condition), and (c) passive viewing (control condition). It was hypothesised that (1) experimental condition (a) and (b) result in greater facial muscle activity than (c), (2) experimental condition (a) increases emotion recognition accuracy from others' faces compared to (c), (3) experimental condition (b) lowers recognition accuracy for expressions with a salient facial feature in the lower, but not the upper face area, compared to (c). Participants (42 males, 42 females) underwent a facial emotion recognition experiment (ADFES-BIV) while electromyography (EMG) was recorded from five facial muscle sites. The experimental conditions' order was counter-balanced. Pen-holding caused stimulus-incongruent facial muscle activity for expressions with facial feature saliency in the lower face region, which reduced recognition of lower face region emotions. Explicit imitation caused stimulus-congruent facial muscle activity without modulating recognition. Methodological implications are discussed.

  3. Guiding intramuscular diaphragm injections using real-time ultrasound and electromyography.

    PubMed

    Sarwal, Aarti; Cartwright, Michael S; Mitchell, Erin; Williams, Koudy; Walker, Francis O; Childers, Martin K

    2015-02-01

    We describe a unique method that combines ultrasound and electromyography to guide intramuscular diaphragm injections in anesthetized large animals. Ultrasound was used to visualize the diaphragm on each side of spontaneously breathing, anesthetized beagle dogs and cynomolgus macaques. An electromyography (EMG) needle was introduced and directed by ultrasound to confirm that the needle entered the muscular portion of the diaphragm, and methylene blue was injected. Injection accuracy was confirmed upon necropsy by tracking the spread of methylene blue. All methylene blue injections were confirmed to have been placed appropriately into the diaphragm. This study demonstrates the feasibility and accuracy of using ultrasound and EMG to guide injections and to reduce complications associated with conventional blind techniques. Ultrasound guidance can be used for clinical EMG of the diaphragm. Future applications may include targeted diaphragm injections with gene replacement therapy in neuromuscular diseases. © 2014 Wiley Periodicals, Inc.

  4. Emotional contagion and trait empathy in prosocial behavior in young people: the contribution of autonomic (facial feedback) and balanced emotional empathy scale (BEES) measures.

    PubMed

    Balconi, Michela; Canavesio, Ylenia

    2013-01-01

    The present research investigated first the facial feedback measured by EMG (electromyography) during decisions to engage in prosocial-helping behaviors and secondly the relation between this psychophysiological correlate and emotional empathy trait in young people. Thirty young subjects were invited to choose to adopt or not a prosocial behavior in response to social interactions. An increased zygomatic and corrugator muscle activity was found in response to prosocial interventions. Moreover, a significant positive correlation was found between empathic profile and the EMG modulation. These results highlight the role of emotions and empathy in prosocial behavior, induced by an "emotional contagion effect."

  5. Spike shape analysis of electromyography for parkinsonian tremor evaluation.

    PubMed

    Marusiak, Jarosław; Andrzejewska, Renata; Świercz, Dominika; Kisiel-Sajewicz, Katarzyna; Jaskólska, Anna; Jaskólski, Artur

    2015-12-01

    Standard electromyography (EMG) parameters have limited utility for evaluation of Parkinson disease (PD) tremor. Spike shape analysis (SSA) EMG parameters are more sensitive than standard EMG parameters for studying motor control mechanisms in healthy subjects. SSA of EMG has not been used to assess parkinsonian tremor. This study assessed the utility of SSA and standard time and frequency analysis for electromyographic evaluation of PD-related resting tremor. We analyzed 1-s periods of EMG recordings to detect nontremor and tremor signals in relaxed biceps brachii muscle of seven mild to moderate PD patients. SSA revealed higher mean spike amplitude, duration, and slope and lower mean spike frequency in tremor signals than in nontremor signals. Standard EMG parameters (root mean square, median, and mean frequency) did not show differences between the tremor and nontremor signals. SSA of EMG data is a sensitive method for parkinsonian tremor evaluation. © 2015 Wiley Periodicals, Inc.

  6. Surface electromyography in animals: A systematic review

    PubMed Central

    Valentin, Stephanie; Zsoldos, Rebeka R.

    2017-01-01

    The study of muscle activity using surface electromyography (sEMG) is commonly used for investigations of the neuromuscular system in man. Although sEMG has faced methodological challenges, considerable technical advances have been made in the last few decades. Similarly, the field of animal biomechanics, including sEMG, has grown despite being confronted with often complex experimental conditions. In human sEMG research, standardised protocols have been developed, however these are lacking in animal sEMG. Before standards can be proposed in this population group, the existing research in animal sEMG should be collated and evaluated. Therefore the aim of this review is to systematically identify and summarise the literature in animal sEMG focussing on (1) species, breeds, activities and muscles investigated, and (2) electrode placement and normalisation methods used. The databases PubMed, Web of Science, Scopus, and Vetmed Resource were searched systematically for sEMG studies in animals and 38 articles were included in the final review. Data on methodological quality was collected and summarised. The findings from this systematic review indicate the divergence in animal sEMG methodology and as a result, future steps required to develop standardisation in animal sEMG are proposed. PMID:26763600

  7. The Perception and Mimicry of Facial Movements Predict Judgments of Smile Authenticity

    PubMed Central

    Korb, Sebastian; With, Stéphane; Niedenthal, Paula; Kaiser, Susanne; Grandjean, Didier

    2014-01-01

    The mechanisms through which people perceive different types of smiles and judge their authenticity remain unclear. Here, 19 different types of smiles were created based on the Facial Action Coding System (FACS), using highly controlled, dynamic avatar faces. Participants observed short videos of smiles while their facial mimicry was measured with electromyography (EMG) over four facial muscles. Smile authenticity was judged after each trial. Avatar attractiveness was judged once in response to each avatar’s neutral face. Results suggest that, in contrast to most earlier work using static pictures as stimuli, participants relied less on the Duchenne marker (the presence of crow’s feet wrinkles around the eyes) in their judgments of authenticity. Furthermore, mimicry of smiles occurred in the Zygomaticus Major, Orbicularis Oculi, and Corrugator muscles. Consistent with theories of embodied cognition, activity in these muscles predicted authenticity judgments, suggesting that facial mimicry influences the perception of smiles. However, no significant mediation effect of facial mimicry was found. Avatar attractiveness did not predict authenticity judgments or mimicry patterns. PMID:24918939

  8. I Can Stomach That! Fearlessness About Death Predicts Attenuated Facial Electromyography Activity in Response to Death-Related Images.

    PubMed

    Velkoff, Elizabeth A; Forrest, Lauren N; Dodd, Dorian R; Smith, April R

    2016-06-01

    Objective measures of suicide risk can convey life-saving information to clinicians, but few such measures exist. This study examined an objective measure of fearlessness about death (FAD), testing whether FAD relates to self-reported and physiological aversion to death. Females (n = 87) reported FAD and disgust sensitivity, and facial electromyography was used to measure physiological facial responses consistent with disgust while viewing death-related images. FAD predicted attenuated expression of physiological death aversion, even when controlling for self-reported death-related disgust sensitivity. Diminished physiological aversion to death-related stimuli holds promise as an objective measure of FAD and suicide risk. © 2015 The American Association of Suicidology.

  9. Capacitively coupled EMG detection via ultra-low-power microcontroller STFT.

    PubMed

    Roland, Theresa; Baumgartner, Werner; Amsuess, Sebastian; Russold, Michael F

    2017-07-01

    As motion artefacts are a major problem with electromyography sensors, a new algorithm is developed to differentiate artefacts to contraction EMG. The performance of myoelectric prosthesis is increased with this algorithm. The implementation is done for an ultra-low-power microcontroller with limited calculation resources and memory. Short Time Fourier Transformation is used to enable real-time application. The sum of the differences (SOD) of the currently measured EMG to a reference contraction EMG is calculated. The SOD is a new parameter introduced for EMG classification. The satisfactory error rates are determined by measurements done with the capacitively coupling EMG prototype, recently developed by the research group.

  10. The risk of hematoma following extensive electromyography of the lumbar paraspinal muscles

    PubMed Central

    London, Zachary; Quint, Douglas J.; Haig, Andrew J.; Yamakawa, Karen S. J.

    2012-01-01

    Introduction The purpose of this study is to provide a controlled trial looking at the risk of paraspinal hematoma formation following extensive paraspinal muscle electromyography. Methods 54 subjects ages 55-80 underwent MRI of the lumbar spine before or shortly after electromyography using the paraspinal mapping technique. A neuroradiologist, blinded to the temporal relationship between the EMG and MRI, reviewed the MRIs to look for hematomas in or around the paraspinal muscles. Results Two MRIs demonstrated definite paraspinal hematomas, while 10 were found to have possible hematomas. All hematomas were < 15 mm, and none were close to any neural structures. There was no relationship between MRI evidence of hematoma and either the timing of the EMG or the use of aspirin or other non-steroidal anti-inflammatory drugs. Discussion Paraspinal electromyography can be considered safe in the general population and those taking non-steroidal anti-inflammatory drugs. PMID:22644875

  11. Embroidered Electromyography: A Systematic Design Guide.

    PubMed

    Shafti, Ali; Ribas Manero, Roger B; Borg, Amanda M; Althoefer, Kaspar; Howard, Matthew J

    2017-09-01

    Muscle activity monitoring or electromyography (EMG) is a useful tool. However, EMG is typically invasive, expensive and difficult to use for untrained users. A possible solution is textile-based surface EMG (sEMG) integrated into clothing as a wearable device. This is, however, challenging due to 1) uncertainties in the electrical properties of conductive threads used for electrodes, 2) imprecise fabrication technologies (e.g., embroidery, sewing), and 3) lack of standardization in design variable selection. This paper, for the first time, provides a design guide for such sensors by performing a thorough examination of the effect of design variables on sEMG signal quality. Results show that imprecisions in digital embroidery lead to a trade-off between low electrode impedance and high manufacturing consistency. An optimum set of variables for this trade-off is identified and tested with sEMG during a variable force isometric grip exercise with n = 12 participants, compared with conventional gel-based electrodes. Results show that thread-based electrodes provide a similar level of sensitivity to force variation as gel-based electrodes with about 90% correlation to expected linear behavior. As proof of concept, jogging leggings with integrated embroidered sEMG are made and successfully tested for detection of muscle fatigue while running on different surfaces.

  12. Noninvasive Uterine Electromyography For Prediction of Preterm Delivery*

    PubMed Central

    UCOVNIK, Miha L; MANER, William L.; CHAMBLISS, Linda R.; BLUMRICK, Richard; BALDUCCI, James; NOVAK-ANTOLIC, Ziva; GARFIELD, Robert E.

    2011-01-01

    Objective Power spectrum (PS) of uterine electromyography (EMG) can identify true labor. EMG propagation velocity (PV) to diagnose labor has not been reported. The objective was to compare uterine EMG against current methods to predict preterm delivery. Study design EMG was recorded in 116 patients (preterm labor, n=20; preterm non-labor, n=68; term labor, n=22; term non-labor, n=6). Student’s t-test was used to compare EMG values for labor vs. non-labor (P<0.05 significant). Predictive values of EMG, Bishop-score, contractions on tocogram, and transvaginal cervical length were calculated using receiver-operator-characteristics analysis. Results PV was higher in preterm and term labor compared with non-labor (P<0.001). Combined PV and PS peak frequency predicted preterm delivery within 7 days with area-under-the-curve (AUC) = 0.96. Bishop score, contractions, and cervical length had AUC of 0.72, 0.67, and 0.54. Conclusions Uterine EMG PV and PS peak frequency more accurately identify true preterm labor than clinical methods. PMID:21145033

  13. Uses of electromyography in dentistry: An overview with meta-analysis.

    PubMed

    Nishi, Shamima Easmin; Basri, Rehana; Alam, Mohammad Khursheed

    2016-01-01

    The purpose of this study was to review the uses of electromyography (EMG) in dentistry in the last few years in related research. EMG is an advanced technique to record and evaluate muscle activity. In the previous days, EMG was only used for medical sciences, but now EMG playing a tremendous role in medical as well as dental sector. Several electronic databases such as Google Scholar, PubMed, Science Direct, and Web of Science were systematically searched for studies published until July 2015. EMG can be used in both diagnosis and treatment purpose to record neuromuscular activity. In dentistry, we can utilize EMG to evaluate muscular activity in function such as chewing and biting or parafunctional activities such as clenching and bruxism. In case of TMJ and myofascial pain disorders, EMG widely is used in the last few years. EMG is one of biometric tests that occur in the modern evidence-based dentistry practice.

  14. Surface electromyography in animal biomechanics: A systematic review.

    PubMed

    Valentin, Stephanie; Zsoldos, Rebeka R

    2016-06-01

    The study of muscle activity using surface electromyography (sEMG) is commonly used for investigations of the neuromuscular system in man. Although sEMG has faced methodological challenges, considerable technical advances have been made in the last few decades. Similarly, the field of animal biomechanics, including sEMG, has grown despite being confronted with often complex experimental conditions. In human sEMG research, standardised protocols have been developed, however these are lacking in animal sEMG. Before standards can be proposed in this population group, the existing research in animal sEMG should be collated and evaluated. Therefore the aim of this review is to systematically identify and summarise the literature in animal sEMG focussing on (1) species, breeds, activities and muscles investigated, and (2) electrode placement and normalisation methods used. The databases PubMed, Web of Science, Scopus, and Vetmed Resource were searched systematically for sEMG studies in animals and 38 articles were included in the final review. Data on methodological quality was collected and summarised. The findings from this systematic review indicate the divergence in animal sEMG methodology and as a result, future steps required to develop standardisation in animal sEMG are proposed. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. More than mere mimicry? The influence of emotion on rapid facial reactions to faces.

    PubMed

    Moody, Eric J; McIntosh, Daniel N; Mann, Laura J; Weisser, Kimberly R

    2007-05-01

    Within a second of seeing an emotional facial expression, people typically match that expression. These rapid facial reactions (RFRs), often termed mimicry, are implicated in emotional contagion, social perception, and embodied affect, yet ambiguity remains regarding the mechanism(s) involved. Two studies evaluated whether RFRs to faces are solely nonaffective motor responses or whether emotional processes are involved. Brow (corrugator, related to anger) and forehead (frontalis, related to fear) activity were recorded using facial electromyography (EMG) while undergraduates in two conditions (fear induction vs. neutral) viewed fear, anger, and neutral facial expressions. As predicted, fear induction increased fear expressions to angry faces within 1000 ms of exposure, demonstrating an emotional component of RFRs. This did not merely reflect increased fear from the induction, because responses to neutral faces were unaffected. Considering RFRs to be merely nonaffective automatic reactions is inaccurate. RFRs are not purely motor mimicry; emotion influences early facial responses to faces. The relevance of these data to emotional contagion, autism, and the mirror system-based perspectives on imitation is discussed.

  16. Requests for electromyography in Rome: a critical evaluation

    PubMed Central

    Di Fabio, Roberto; Castagnoli, Claudio; Madrigale, Andrea; Barrella, Massimo; Serrao, Mariano; Pierelli, Francesco

    2013-01-01

    Summary To date, there exist no data reporting the level of suitability of requests for electromyography examinations (EMGs) in Rome. The records of 1,220 consecutive patients (age: 57.6±15.0 years; 400 M, 820 F) in two neurophysiology laboratories were collected and analyzed. In total, 1,317 EMGs were requested, mainly by general practitioners (GPs) (57%) and orthopedic specialists (18%). The most common diagnoses were L4-L5 radiculopathy (22%) and carpal tunnel syndrome (21%); 332 examinations (25%) were normal. 68% of requests were not accompanied by any specific query. The concordance between initial hypothesis/final post-EMG diagnosis was low (<20%). When a specific query was indicated, the initial suspicion was confirmed by EMG in 54% of GP requests and 64% of requests by specialists (p=0.03). No difference in diagnostic ability was found between specialists (p>0.05). In 17% of cases, the EMG was deemed diagnostically useless by the neurophysiologist, which seems to indicate potentially suboptimal prescription of EMGs. PMID:24598396

  17. Techniques of EMG signal analysis: detection, processing, classification and applications

    PubMed Central

    Hussain, M.S.; Mohd-Yasin, F.

    2006-01-01

    Electromyography (EMG) signals can be used for clinical/biomedical applications, Evolvable Hardware Chip (EHW) development, and modern human computer interaction. EMG signals acquired from muscles require advanced methods for detection, decomposition, processing, and classification. The purpose of this paper is to illustrate the various methodologies and algorithms for EMG signal analysis to provide efficient and effective ways of understanding the signal and its nature. We further point up some of the hardware implementations using EMG focusing on applications related to prosthetic hand control, grasp recognition, and human computer interaction. A comparison study is also given to show performance of various EMG signal analysis methods. This paper provides researchers a good understanding of EMG signal and its analysis procedures. This knowledge will help them develop more powerful, flexible, and efficient applications. PMID:16799694

  18. Facial nerve mapping and monitoring in lymphatic malformation surgery.

    PubMed

    Chiara, Jospeh; Kinney, Greg; Slimp, Jefferson; Lee, Gi Soo; Oliaei, Sepehr; Perkins, Jonathan A

    2009-10-01

    Establish the efficacy of preoperative facial nerve mapping and continuous intraoperative EMG monitoring in protecting the facial nerve during resection of cervicofacial lymphatic malformations. Retrospective study in which patients were clinically followed for at least 6 months postoperatively, and long-term outcome was evaluated. Patient demographics, lesion characteristics (i.e., size, stage, location) were recorded. Operative notes revealed surgical techniques, findings, and complications. Preoperative, short-/long-term postoperative facial nerve function was standardized using the House-Brackmann Classification. Mapping was done prior to incision by percutaneously stimulating the facial nerve and its branches and recording the motor responses. Intraoperative monitoring and mapping were accomplished using a four-channel, free-running EMG. Neurophysiologists continuously monitored EMG responses and blindly analyzed intraoperative findings and final EMG interpretations for abnormalities. Seven patients collectively underwent 8 lymphatic malformation surgeries. Median age was 30 months (2-105 months). Lymphatic malformation diagnosis was recorded in 6/8 surgeries. Facial nerve function was House-Brackmann grade I in 8/8 cases preoperatively. Facial nerve was abnormally elongated in 1/8 cases. EMG monitoring recorded abnormal activity in 4/8 cases--two suggesting facial nerve irritation, and two with possible facial nerve damage. Transient or long-term facial nerve paresis occurred in 1/8 cases (House-Brackmann grade II). Preoperative facial nerve mapping combined with continuous intraoperative EMG and mapping is a successful method of identifying the facial nerve course and protecting it from injury during resection of cervicofacial lymphatic malformations involving the facial nerve.

  19. Masseter and temporalis muscle electromyography findings after lower third molar extraction

    PubMed Central

    Buesa-Bárez, José-María; Martínez-Rodríguez, Natalia; Barona-Dorado, Cristina; Sanz-Alonso, Javier; Cortés-Bretón-Brinkmann, Jorge; Martínez-González, José-María

    2018-01-01

    Background The main clinical application of electromyography is to detect abnormalities in muscle function, to assess muscle activity for purposes of recruitment, and in the biomechanics of movement. Objectives To analyze electromyography (EMG) findings for masticatory muscles during chewing following surgical extraction of lower third molars, and to determine any correlation between pain, inflammation, trismus, and the EMG data registered. Material and Methods This prospective study included 31 patients. Surface EMG was used to study masseter and temporalis muscle function before lower third molar extraction and 72 hours and seven days after surgery. Clinical variables, pain, inflammation, and trismus were registered before and after surgery. Results Studying the area and size of the masticatory muscles, higher values were found for temporalis than masseter muscles, regardless of the surgical side, which points to the greater involvement of the temporalis muscle in mastication. Comparing the side where surgery had been performed with the non-surgical side, a sharp and statistically significant reduction in amplitude and area were noted on the surgical side reflecting major functional affectation. One week after surgery, amplitude and area had almost returned to base-line values, indicating almost complete recovery. While pain decreased progressively after surgery, inflammation peaked at 72 hours, while mouth opening reached a minimum at this time, returning to normality within the week. Conclusions Surgical extraction of lower third molars produces changes to electromyography activity that are more evident during the first hours after surgery and closely related to the intensity of pain suffered and the patient’s inflammatory responses, although they are not related to mouth opening capacity. Key words:Third molar surgery, electromyography, pain, inflammation, trismus, masticatory muscles. PMID:29274163

  20. Electromyography as a recording system for eyeblink conditioning with functional magnetic resonance imaging.

    PubMed

    Knuttinen, M-G; Parrish, T B; Weiss, C; LaBar, K S; Gitelman, D R; Power, J M; Mesulam, M-M; Disterhoft, J F

    2002-10-01

    This study was designed to develop a suitable method of recording eyeblink responses while conducting functional magnetic resonance imaging (fMRI). Given the complexity of this behavioral setup outside of the magnet, this study sought to adapt and further optimize an approach to eyeblink conditioning that would be suitable for conducting event-related fMRI experiments. This method involved the acquisition of electromyographic (EMG) signals from the orbicularis oculi of the right eye, which were subsequently amplified and converted into an optical signal outside of the head coil. This optical signal was converted back into an electrical signal once outside the magnet room. Electromyography (EMG)-detected eyeblinks were used to measure responses in a delay eyeblink conditioning paradigm. Our results indicate that: (1) electromyography is a sensitive method for the detection of eyeblinks during fMRI; (2) minimal interactions or artifacts of the EMG signal were created from the magnetic resonance pulse sequence; and (3) no electromyography-related artifacts were detected in the magnetic resonance images. Furthermore, an analysis of the functional data showed areas of activation that have previously been shown in positron emission tomography studies of human eyeblink conditioning. Our results support the strength of this behavioral setup as a suitable method to be used in association with fMRI.

  1. Further evidence for unconscious learning: preliminary support for the conditioning of facial EMG to subliminal stimuli.

    PubMed

    Bunce, S C; Bernat, E; Wong, P S; Shevrin, H

    1999-01-01

    This study investigated the predictive validity of facial electromyograms (EMGs) in a subliminal conditioning paradigm. Two schematic faces (pleasant; CS- and unpleasant; CS+), were presented to eight right-handed males during supraliminal pre- and postconditioning phases. Subliminal conditioning consisted of 36 energy-masked presentations of each face pairing the CS+ with an aversive shock 800 ms poststimulus. A forced-choice recognition task established that the energy mask effectively precluded conscious recognition of stimuli. For the obicularis oculi and corrugator EMGs, significant face x condition interactions were found at 20-100 ms and 400-792 ms poststimulus. The results demonstrate the existence of an expressive motoric response related to affect operating in response to a learned but unconscious event. Subjects were not aware of a contingency between the CS+ and the US, suggesting emotional contingencies can be unconsciously acquired.

  2. Bell's palsy and partial hypoglossal to facial nerve transfer: Case presentation and literature review

    PubMed Central

    Socolovsky, Mariano; Páez, Miguel Domínguez; Masi, Gilda Di; Molina, Gonzalo; Fernández, Eduardo

    2012-01-01

    Background: Idiopathic facial nerve palsy (Bell's palsy) is a very common condition that affects active population. Despite its generally benign course, a minority of patients can remain with permanent and severe sequelae, including facial palsy or dyskinesia. Hypoglossal to facial nerve anastomosis is rarely used to reinnervate the mimic muscle in these patients. In this paper, we present a case where a direct partial hypoglossal to facial nerve transfer was used to reinnervate the upper and lower face. We also discuss the indications of this procedure. Case Description: A 53-year-old woman presenting a spontaneous complete (House and Brackmann grade 6) facial palsy on her left side showed no improvement after 13 months of conservative treatment. Electromyography (EMG) showed complete denervation of the mimic muscles. A direct partial hypoglossal to facial nerve anastomosis was performed, including dissection of the facial nerve at the fallopian canal. One year after the procedure, the patient showed House and Brackmann grade 3 function in her affected face. Conclusions: Partial hypoglossal–facial anastomosis with intratemporal drilling of the facial nerve is a viable technique in the rare cases in which severe Bell's palsy does not recover spontaneously. Only carefully selected patients can really benefit from this technique. PMID:22574255

  3. The Response of Hyperkinesis to EMG Biofeedback.

    ERIC Educational Resources Information Center

    Haight, Maryellen J.; And Others

    A study was conducted involving eight hyperkinetic males (11-15 years old) to determine if Ss receiving electromyography (EMG) biofeedback training would show a reduction in frontalis muscle tension, hyperactivity, and lability, and increases in self-esteem and visual and auditory attention span. Individual 45- and 30-minute relaxation exercises…

  4. NON-INVASIVE 3D FACIAL ANALYSIS AND SURFACE ELECTROMYOGRAPHY DURING FUNCTIONAL PRE-ORTHODONTIC THERAPY: A PRELIMINARY REPORT

    PubMed Central

    Tartaglia, Gianluca M.; Grandi, Gaia; Mian, Fabrizio; Sforza, Chiarella; Ferrario, Virgilio F.

    2009-01-01

    Objectives: Functional orthodontic devices can modify oral function thus permitting more adequate growth processes. The assessment of their effects should include both facial morphology and muscle function. This preliminary study investigated whether a preformed functional orthodontic device could induce variations in facial morphology and function along with correction of oral dysfunction in a group of orthodontic patients in the mixed and early permanent dentitions. Material and Methods: The three-dimensional coordinates of 50 facial landmarks (forehead, eyes, nose, cheeks, mouth, jaw and ears) were collected in 10 orthodontic male patients aged 8-13 years, and in 89 healthy reference boys of the same age. Soft tissue facial angles, distances, and ratios were computed. Surface electromyography of the masseter and temporalis muscles was performed, and standardized symmetry, muscular torque and activity were calculated. Soft-tissue facial modifications were analyzed non-invasively before and after a 6-month treatment with a functional device. Comparisons were made with z-scores and paired Student's t-tests. Results: The 6-month treatment stimulated mandibular growth in the anterior and inferior directions, with significant variations in three-dimensional facial divergence and facial convexity. The modifications were larger in the patients than in reference children. In several occasions, the discrepancies relative to the norm became not significant after treatment. No significant variations in standardized muscular activity were found. Conclusions: Preliminary results showed that the continuous and correct use of the functional device induced measurable intraoral (dental arches) and extraoral (face) morphological modifications. The device did not modify the functional equilibrium of the masticatory muscles. PMID:19936531

  5. Non-invasive 3D facial analysis and surface electromyography during functional pre-orthodontic therapy: a preliminary report.

    PubMed

    Tartaglia, Gianluca M; Grandi, Gaia; Mian, Fabrizio; Sforza, Chiarella; Ferrario, Virgilio F

    2009-01-01

    Functional orthodontic devices can modify oral function thus permitting more adequate growth processes. The assessment of their effects should include both facial morphology and muscle function. This preliminary study investigated whether a preformed functional orthodontic device could induce variations in facial morphology and function along with correction of oral dysfunction in a group of orthodontic patients in the mixed and early permanent dentitions. The three-dimensional coordinates of 50 facial landmarks (forehead, eyes, nose, cheeks, mouth, jaw and ears) were collected in 10 orthodontic male patients aged 8-13 years, and in 89 healthy reference boys of the same age. Soft tissue facial angles, distances, and ratios were computed. Surface electromyography of the masseter and temporalis muscles was performed, and standardized symmetry, muscular torque and activity were calculated. Soft-tissue facial modifications were analyzed non-invasively before and after a 6-month treatment with a functional device. Comparisons were made with z-scores and paired Student's t-tests. The 6-month treatment stimulated mandibular growth in the anterior and inferior directions, with significant variations in three-dimensional facial divergence and facial convexity. The modifications were larger in the patients than in reference children. In several occasions, the discrepancies relative to the norm became not significant after treatment. No significant variations in standardized muscular activity were found. Preliminary results showed that the continuous and correct use of the functional device induced measurable intraoral (dental arches) and extraoral (face) morphological modifications. The device did not modify the functional equilibrium of the masticatory muscles.

  6. Swallowing in patients with Parkinson's disease: a surface electromyography study.

    PubMed

    Ws Coriolano, Maria das Graças; R Belo, Luciana; Carneiro, Danielle; G Asano, Amdore; Al Oliveira, Paulo José; da Silva, Douglas Monteiro; G Lins, Otávio

    2012-12-01

    Our goal was to study deglutition of Parkinson's disease (PD) patients and normal controls (NC) using surface electromyography (sEMG). The study included 15 patients with idiopathic PD and 15 age-matched normal controls. Surface electromyography was collected over the suprahyoid muscle group. Conditions were the following: swallow at once 10 and 20 ml of water and 5 and 10 ml of yogurt of firm consistency, and freely drink 100 ml of water. During swallowing, durations of sEMG were significantly longer in PD patients than in normal controls but no significant differences of amplitudes were found. Eighty percent of the PD patients and 20 % of the NC needed more than one swallow to consume 20 ml of water, while 70 % of the PD patients and none of the NC needed more than one swallow to consume 5 ml of yogurt. PD patients took significantly more time and needed significantly more swallows to drink 100 ml of water than normal controls. We conclude that sEMG might be a simple and useful tool to study and monitor deglutition in PD patients.

  7. Endomicroscopy and electromyography of neuromuscular junctions in situ

    PubMed Central

    Brown, Rosalind; Dissanayake, Kosala N; Skehel, Paul A; Ribchester, Richard R

    2014-01-01

    Objective Electromyography (EMG) is used routinely to diagnose neuromuscular dysfunction in a wide range of peripheral neuropathies, myopathies, and neuromuscular degenerative diseases including motor neuron diseases such as amyotrophic lateral sclerosis (ALS). Definitive neurological diagnosis may also be indicated by the analysis of pathological neuromuscular innervation in motor-point biopsies. Our objective in this study was to preempt motor-point biopsy by combining live imaging with electrophysiological analysis of slow degeneration of neuromuscular junctions (NMJs) in vivo. Methods We combined conventional needle electromyography with fiber-optic confocal endomicroscopy (CEM), using an integrated hand-held, 1.5-mm-diameter probe. We utilized as a test bed, various axotomized muscles in the hind limbs of anaesthetized, double-homozygous thy1.2YFP16: WldS mice, which coexpress the Wallerian-degeneration Slow (WldS) protein and yellow fluorescent protein (YFP) in motor neurons. We also tested exogenous vital stains, including Alexa488-α-bungarotoxin; the styryl pyridinium dye 4-Di-2-Asp; and a GFP conjugate of botulinum toxin Type A heavy chain (GFP-HcBoNT/A). Results We show that an integrated EMG/CEM probe is effective in longitudinal evaluation of functional and morphological changes that take place over a 7-day period during axotomy-induced, slow neuromuscular synaptic degeneration. EMG amplitude declined in parallel with overt degeneration of motor nerve terminals. EMG/CEM was safe and effective when nerve terminals and motor endplates were selectively stained with vital dyes. Interpretation Our findings constitute proof-of-concept, based on live imaging in an animal model, that combining EMG/CEM may be useful as a minimally invasive precursor or alternative to motor-point biopsy in neurological diagnosis and for monitoring local administration of potential therapeutics. PMID:25540801

  8. siGnum: graphical user interface for EMG signal analysis.

    PubMed

    Kaur, Manvinder; Mathur, Shilpi; Bhatia, Dinesh; Verma, Suresh

    2015-01-01

    Electromyography (EMG) signals that represent the electrical activity of muscles can be used for various clinical and biomedical applications. These are complicated and highly varying signals that are dependent on anatomical location and physiological properties of the muscles. EMG signals acquired from the muscles require advanced methods for detection, decomposition and processing. This paper proposes a novel Graphical User Interface (GUI) siGnum developed in MATLAB that will apply efficient and effective techniques on processing of the raw EMG signals and decompose it in a simpler manner. It could be used independent of MATLAB software by employing a deploy tool. This would enable researcher's to gain good understanding of EMG signal and its analysis procedures that can be utilized for more powerful, flexible and efficient applications in near future.

  9. Electromyography assessment in zygomaticomaxillary complex fractures.

    PubMed

    Waheed El-Anwar, Mohammad; Elsheikh, Ezzeddin; Sweed, Ahmed Hassan; Ezzeldin, Nillie

    2015-12-01

    The aim of this study was to assess the activity of the masseter and temporalis muscles using surface electromyography (EMG) in patients with zygomaticomaxillary complex (ZMC) fractures. This prospective study was carried out on 25 patients who had ZMC fractures. Fifteen patients were managed by open reduction and rigid fixation (ORIF) using titanium miniplates. This study, using surface electromyography, analyzed the activity of the masseter and temporalis muscles of 25 patients with ZMC fractures; 15 of them were surgically treated under general anesthesia (GA). Evaluations were made before surgery and 6 weeks after surgery by recording the mean of muscle contraction of 20 motor unit action potential (MUAP) against resistance, and statistical analyses were performed. A significant EMG difference between the normal and ZMC fracture sides was found (P < 0.0001) for both masseter and temporalis muscles and was significantly improved after ORIF. However, postoperative EMV values of the repaired side was significantly less than measured postoperatively in the normal side (P < 0.0001) for both muscles. ZMC fractures significantly diminish muscular activity of the masseter and temporalis and even though significant recovery of muscle activity was revealed after 6 weeks, it is still less than normal activity, highlighting the importance of postoperative rehabilitation.

  10. Detection of convulsive seizures using surface electromyography.

    PubMed

    Beniczky, Sándor; Conradsen, Isa; Wolf, Peter

    2018-06-01

    Bilateral (generalized) tonic-clonic seizures (TCS) increase the risk of sudden unexpected death in epilepsy (SUDEP), especially when patients are unattended. In sleep, TCS often remain unnoticed, which can result in suboptimal treatment decisions. There is a need for automated detection of these major epileptic seizures, using wearable devices. Quantitative surface electromyography (EMG) changes are specific for TCS and characterized by a dynamic evolution of low- and high-frequency signal components. Algorithms targeting increase in high-frequency EMG signals constitute biomarkers of TCS; they can be used both for seizure detection and for differentiating TCS from convulsive nonepileptic seizures. Two large-scale, blinded, prospective studies demonstrated the accuracy of wearable EMG devices for detecting TCS with high sensitivity (76%-100%). The rate of false alarms (0.7-2.5/24 h) needs further improvement. This article summarizes the pathophysiology of muscle activation during convulsive seizures and reviews the published evidence on the accuracy of EMG-based seizure detection. Wiley Periodicals, Inc. © 2018 International League Against Epilepsy.

  11. Does Heel Height Cause Imbalance during Sit-to-Stand Task: Surface EMG Perspective

    PubMed Central

    Naik, Ganesh R.; Al-Ani, Ahmed; Gobbo, Massimiliano; Nguyen, Hung T.

    2017-01-01

    The purpose of this study was to determine whether electromyography (EMG) muscle activities around the knee differ during sit-to-stand (STS) and returning task for females wearing shoes with different heel heights. Sixteen healthy young women (age = 25.2 ± 3.9 years, body mass index = 20.8 ± 2.7 kg/m2) participated in this study. Electromyography signals were recorded from the two muscles, vastus medialis (VM) and vastus lateralis (VL) that involve in the extension of knee. The participants wore shoes with five different heights, including 4, 6, 8, 10, and 12 cm. Surface electromyography (sEMG) data were acquired during STS and stand-to-sit-returning (STSR) tasks. The data was filtered using a fourth order Butterworth (band pass) filter of 20–450 Hz frequency range. For each heel height, we extracted median frequency (MDF) and root mean square (RMS) features to measure sEMG activities between VM and VL muscles. The experimental results (based on MDF and RMS-values) indicated that there is imbalance between vasti muscles for more elevated heels. The results are also quantified with statistical measures. The study findings suggest that there would be an increased likelihood of knee imbalance and fatigue with regular usage of high heel shoes (HHS) in women. PMID:28894422

  12. Reliability of surface electromyography in the assessment of paraspinal muscle fatigue: an updated systematic review.

    PubMed

    Mohseni Bandpei, Mohammad A; Rahmani, Nahid; Majdoleslam, Basir; Abdollahi, Iraj; Ali, Shabnam Shah; Ahmad, Ashfaq

    2014-09-01

    The purpose of this study was to review the literature to determine whether surface electromyography (EMG) is a reliable tool to assess paraspinal muscle fatigue in healthy subjects and in patients with low back pain (LBP). A literature search for the period of 2000 to 2012 was performed, using PubMed, ProQuest, Science Direct, EMBASE, OVID, CINAHL, and MEDLINE databases. Electromyography, reliability, median frequency, paraspinal muscle, endurance, low back pain, and muscle fatigue were used as keywords. The literature search yielded 178 studies using the above keywords. Twelve articles were selected according to the inclusion criteria of the study. In 7 of the 12 studies, the surface EMG was only applied in healthy subjects, and in 5 studies, the reliability of surface EMG was investigated in patients with LBP or a comparison with a control group. In all of these studies, median frequency was shown to be a reliable EMG parameter to assess paraspinal muscles fatigue. There was a wide variation among studies in terms of methodology, surface EMG parameters, electrode location, procedure, and homogeneity of the study population. The results suggest that there seems to be a convincing body of evidence to support the merit of surface EMG in the assessment of paraspinal muscle fatigue in healthy subject and in patients with LBP. Copyright © 2014 National University of Health Sciences. Published by Elsevier Inc. All rights reserved.

  13. Tibial and fibular nerves evaluation using intraoperative electromyography in rats.

    PubMed

    Nepomuceno, André Coelho; Politani, Elisa Landucci; Silva, Eduardo Guandelini da; Salomone, Raquel; Longo, Marco Vinicius Losso; Salles, Alessandra Grassi; Faria, José Carlos Marques de; Gemperli, Rolf

    2016-08-01

    To evaluate a new model of intraoperative electromyographic (EMG) assessment of the tibial and fibular nerves, and its respectives motor units in rats. Eight Wistar rats underwent intraoperative EMG on both hind limbs at two different moments: week 0 and week 12. Supramaximal electrical stimulation applied on sciatic nerve, and compound muscle action potential recorded on the gastrocnemius muscle (GM) and the extensor digitorum longus muscle (EDLM) through electrodes at specifics points. Motor function assessment was performaced through Walking Track Test. Exposing the muscles and nerves for examination did not alter tibial (p=0.918) or fibular (p=0.877) function between the evaluation moments. Electromyography of the GM, innervated by the tibial nerve, revealed similar amplitude (p=0.069) and latency (p=0.256) at week 0 and at 12 weeks, creating a standard of normality. Meanwhile, electromyography of the EDLM, innervated by the fibular nerve, showed significant differences between the amplitudes (p=0.003) and latencies (p=0.021) at the two different moments of observation. Intraoperative electromyography determined and quantified gastrocnemius muscle motor unit integrity, innervated by tibial nerve. Although this study was not useful to, objectively, assess extensor digitorum longus muscle motor unit, innervated by fibular nerve.

  14. Effect of vibrotactile feedback on an EMG-based proportional cursor control system.

    PubMed

    Li, Shunchong; Chen, Xingyu; Zhang, Dingguo; Sheng, Xinjun; Zhu, Xiangyang

    2013-01-01

    Surface electromyography (sEMG) has been introduced into the bio-mechatronics systems, however, most of them are lack of the sensory feedback. In this paper, the effect of vibrotactile feedback for a myoelectric cursor control system is investigated quantitatively. Simultaneous and proportional control signals are extracted from EMG using a muscle synergy model. Different types of feedback including vibrotactile feedback and visual feedback are added, assessed and compared with each other. The results show that vibrotactile feedback is capable of improving the performance of EMG-based human machine interface.

  15. Surface Facial Electromyography, Skin Conductance, and Self-Reported Emotional Responses to Light- and Season-Relevant Stimuli in Seasonal Affective Disorder

    PubMed Central

    Lindsey, Kathryn Tierney; Rohan, Kelly J.; Roecklein, Kathryn A.; Mahon, Jennifer N.

    2011-01-01

    Background Learned associations between depressive behavior and environmental stimuli signaling low light availability and winter season may play a role in seasonal affective disorder (SAD). The purpose of this study was to determine whether light and season environmental cues elicit emotional responses that are distinct in individuals with SAD. Methods Twenty-four currently depressed SAD participants were compared to 24 demographically-matched controls with no depression history on emotional responses to outdoor scenes captured under two light intensity (i.e., clear, sunny vs. overcast sky) and three season (i.e., summer with green leaves, fall with autumn foliage, and winter with bare trees) conditions. Emotion measures included surface facial electromyography (EMG) activity in the corrugator supercilii and zygomaticus major muscle regions, skin conductance, and self-reported mood state on the Profile of Mood States Depression–Dejection Subscale. Results Light intensity was a more salient cue than season in determining emotional reactions among SAD participants. Relative to controls, SAD participants displayed more corrugator activity, more frequent significant skin conductance responses (SCR), greater SCR magnitude, and more self-reported depressed mood in response to overcast stimuli and less corrugator activity, lower SCR magnitude, and less self-reported depressed mood in response to sunny stimuli. Limitations Study limitations include the single, as opposed to repeated, assessment and the lack of a nonseasonal depression group. Conclusions These findings suggest that extreme emotional reactivity to light-relevant stimuli may be a correlate of winter depression; and future work should examine its potential onset or maintenance significance. PMID:21600661

  16. Emotional facial activation induced by unconsciously perceived dynamic facial expressions.

    PubMed

    Kaiser, Jakob; Davey, Graham C L; Parkhouse, Thomas; Meeres, Jennifer; Scott, Ryan B

    2016-12-01

    Do facial expressions of emotion influence us when not consciously perceived? Methods to investigate this question have typically relied on brief presentation of static images. In contrast, real facial expressions are dynamic and unfold over several seconds. Recent studies demonstrate that gaze contingent crowding (GCC) can block awareness of dynamic expressions while still inducing behavioural priming effects. The current experiment tested for the first time whether dynamic facial expressions presented using this method can induce unconscious facial activation. Videos of dynamic happy and angry expressions were presented outside participants' conscious awareness while EMG measurements captured activation of the zygomaticus major (active when smiling) and the corrugator supercilii (active when frowning). Forced-choice classification of expressions confirmed they were not consciously perceived, while EMG revealed significant differential activation of facial muscles consistent with the expressions presented. This successful demonstration opens new avenues for research examining the unconscious emotional influences of facial expressions. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Multilevel analysis of facial expressions of emotion and script: self-report (arousal and valence) and psychophysiological correlates.

    PubMed

    Balconi, Michela; Vanutelli, Maria Elide; Finocchiaro, Roberta

    2014-09-26

    The paper explored emotion comprehension in children with regard to facial expression of emotion. The effect of valence and arousal evaluation, of context and of psychophysiological measures was monitored. Indeed subjective evaluation of valence (positive vs. negative) and arousal (high vs. low), and contextual (facial expression vs. facial expression and script) variables were supposed to modulate the psychophysiological responses. Self-report measures (in terms of correct recognition, arousal and valence attribution) and psychophysiological correlates (facial electromyography, EMG, skin conductance response, SCR, and heart rate, HR) were observed when children (N = 26; mean age = 8.75 y; range 6-11 y) looked at six facial expressions of emotions (happiness, anger, fear, sadness, surprise, and disgust) and six emotional scripts (contextualized facial expressions). The competencies about the recognition, the evaluation on valence and arousal was tested in concomitance with psychophysiological variations. Specifically, we tested for the congruence of these multiple measures. Log-linear analysis and repeated measure ANOVAs showed different representations across the subjects, as a function of emotion. Specifically, children' recognition and attribution were well developed for some emotions (such as anger, fear, surprise and happiness), whereas some other emotions (mainly disgust and sadness) were less clearly represented. SCR, HR and EMG measures were modulated by the evaluation based on valence and arousal, with increased psychophysiological values mainly in response to anger, fear and happiness. As shown by multiple regression analysis, a significant consonance was found between self-report measures and psychophysiological behavior, mainly for emotions rated as more arousing and negative in valence. The multilevel measures were discussed at light of dimensional attribution model.

  18. Multilevel analysis of facial expressions of emotion and script: self-report (arousal and valence) and psychophysiological correlates

    PubMed Central

    2014-01-01

    Background The paper explored emotion comprehension in children with regard to facial expression of emotion. The effect of valence and arousal evaluation, of context and of psychophysiological measures was monitored. Indeed subjective evaluation of valence (positive vs. negative) and arousal (high vs. low), and contextual (facial expression vs. facial expression and script) variables were supposed to modulate the psychophysiological responses. Methods Self-report measures (in terms of correct recognition, arousal and valence attribution) and psychophysiological correlates (facial electromyography, EMG, skin conductance response, SCR, and heart rate, HR) were observed when children (N = 26; mean age = 8.75 y; range 6-11 y) looked at six facial expressions of emotions (happiness, anger, fear, sadness, surprise, and disgust) and six emotional scripts (contextualized facial expressions). The competencies about the recognition, the evaluation on valence and arousal was tested in concomitance with psychophysiological variations. Specifically, we tested for the congruence of these multiple measures. Results Log-linear analysis and repeated measure ANOVAs showed different representations across the subjects, as a function of emotion. Specifically, children’ recognition and attribution were well developed for some emotions (such as anger, fear, surprise and happiness), whereas some other emotions (mainly disgust and sadness) were less clearly represented. SCR, HR and EMG measures were modulated by the evaluation based on valence and arousal, with increased psychophysiological values mainly in response to anger, fear and happiness. Conclusions As shown by multiple regression analysis, a significant consonance was found between self-report measures and psychophysiological behavior, mainly for emotions rated as more arousing and negative in valence. The multilevel measures were discussed at light of dimensional attribution model. PMID:25261242

  19. Electromyography and the study of sports movements: a review.

    PubMed

    Clarys, J P; Cabri, J

    1993-10-01

    Within electromyography (EMG), a particular specialty has been developed wherein the aim is to use EMG for the study of muscular function and co-ordination. This area of research is usually called kinesiological EMG. The general aims of kinesiological EMG are to analyse the function and co-ordination of muscles in different movements and postures, in healthy subjects as well as in the disabled, in skilled actions as well as during training, in humans as well as in animals, under laboratory conditions as well as during daily or vocational activities. This is often done by a combination of electromyographical and kinesiological or biomechanical measurement techniques. Because there are over 400 skeletal muscles in the human body and both irregular and complex involvement of the muscles may occur in neuromuscular diseases and in voluntary occupational or sports movements, it is impossible to sample all of the muscles of the entire body during the performance of complex motor skills. In addition, the measurement of kinesiological EMG in sport and specific field circumstances, such as the track and/or soccer field, the alpine ski slope, the swimming pool and the ice rink, demands a specific technological and methodological approach, adaptable to both the field and the sport circumstances. Sport movement techniques and skills, training approaches and methods, ergonomic verification of the human-machine interaction have, amongst others, a highly specialized muscular activity in common. The knowledge of such muscular action in all its aspects, its evaluation and its feedback should allow for the optimization of movement, of sports materials, of training possibilities and, in the end, of sports performance. Drawing conclusions from a review of the EMG research of 32 sports, covering over 100 different complex skills, including methodological approaches, is an impossible task. We have attempted to set standards concerning the EMG methodology at the beginning of this review

  20. Gesture recognition by instantaneous surface EMG images

    PubMed Central

    Geng, Weidong; Du, Yu; Jin, Wenguang; Wei, Wentao; Hu, Yu; Li, Jiajun

    2016-01-01

    Gesture recognition in non-intrusive muscle-computer interfaces is usually based on windowed descriptive and discriminatory surface electromyography (sEMG) features because the recorded amplitude of a myoelectric signal may rapidly fluctuate between voltages above and below zero. Here, we present that the patterns inside the instantaneous values of high-density sEMG enables gesture recognition to be performed merely with sEMG signals at a specific instant. We introduce the concept of an sEMG image spatially composed from high-density sEMG and verify our findings from a computational perspective with experiments on gesture recognition based on sEMG images with a classification scheme of a deep convolutional network. Without any windowed features, the resultant recognition accuracy of an 8-gesture within-subject test reached 89.3% on a single frame of sEMG image and reached 99.0% using simple majority voting over 40 frames with a 1,000 Hz sampling rate. Experiments on the recognition of 52 gestures of NinaPro database and 27 gestures of CSL-HDEMG database also validated that our approach outperforms state-of-the-arts methods. Our findings are a starting point for the development of more fluid and natural muscle-computer interfaces with very little observational latency. For example, active prostheses and exoskeletons based on high-density electrodes could be controlled with instantaneous responses. PMID:27845347

  1. Gesture recognition by instantaneous surface EMG images.

    PubMed

    Geng, Weidong; Du, Yu; Jin, Wenguang; Wei, Wentao; Hu, Yu; Li, Jiajun

    2016-11-15

    Gesture recognition in non-intrusive muscle-computer interfaces is usually based on windowed descriptive and discriminatory surface electromyography (sEMG) features because the recorded amplitude of a myoelectric signal may rapidly fluctuate between voltages above and below zero. Here, we present that the patterns inside the instantaneous values of high-density sEMG enables gesture recognition to be performed merely with sEMG signals at a specific instant. We introduce the concept of an sEMG image spatially composed from high-density sEMG and verify our findings from a computational perspective with experiments on gesture recognition based on sEMG images with a classification scheme of a deep convolutional network. Without any windowed features, the resultant recognition accuracy of an 8-gesture within-subject test reached 89.3% on a single frame of sEMG image and reached 99.0% using simple majority voting over 40 frames with a 1,000 Hz sampling rate. Experiments on the recognition of 52 gestures of NinaPro database and 27 gestures of CSL-HDEMG database also validated that our approach outperforms state-of-the-arts methods. Our findings are a starting point for the development of more fluid and natural muscle-computer interfaces with very little observational latency. For example, active prostheses and exoskeletons based on high-density electrodes could be controlled with instantaneous responses.

  2. Analysis of EMG Signals in Aggressive and Normal Activities by Using Higher-Order Spectra

    PubMed Central

    Sezgin, Necmettin

    2012-01-01

    The analysis and classification of electromyography (EMG) signals are very important in order to detect some symptoms of diseases, prosthetic arm/leg control, and so on. In this study, an EMG signal was analyzed using bispectrum, which belongs to a family of higher-order spectra. An EMG signal is the electrical potential difference of muscle cells. The EMG signals used in the present study are aggressive or normal actions. The EMG dataset was obtained from the machine learning repository. First, the aggressive and normal EMG activities were analyzed using bispectrum and the quadratic phase coupling of each EMG episode was determined. Next, the features of the analyzed EMG signals were fed into learning machines to separate the aggressive and normal actions. The best classification result was 99.75%, which is sufficient to significantly classify the aggressive and normal actions. PMID:23193379

  3. Intramuscular pressure and electromyography as indexes of force during isokinetic exercise

    NASA Technical Reports Server (NTRS)

    Aratow, M.; Ballard, R. E.; Grenshaw, A. G.; Styf, J.; Watenpaugh, D. E.; Kahan, N. J.; Hargens, A. R.

    1993-01-01

    A direct method for measuring force production of specific muscles during dynamic exercise is presently unavailable. Previous studies indicate that both intramuscular pressure (IMP) and electromyography (EMG) correlate linearly with muscle contraction force during isometric exercise. The objective of this study was to compare IMP and EMG as linear assessors of muscle contraction force during dynamic exercise. IMP and surface EMG activity were recorded during concentric and eccentric isokinetic plantarflexion and dorsiflexion of the ankle joint from the tibialis anterior (TA) and soleus (SOL) muscles of nine male volunteers. Ankle torque was measured using a dynamometer, and IMP was measured via catheterization. IMP exhibited better linear correlation than EMG with ankle joint torque during concentric contractions of the SOL and the TA, as well as during eccentric contractions. IMP provides a better index of muscle contraction force than EMG during concentric and eccentric exercise through the entire range of torque. IMP reflects intrinsic mechanical properties of individual muscles, such as length-tension relationships, which EMG is unable to assess.

  4. sEMG Signal Acquisition Strategy towards Hand FES Control.

    PubMed

    Toledo-Peral, Cinthya Lourdes; Gutiérrez-Martínez, Josefina; Mercado-Gutiérrez, Jorge Airy; Martín-Vignon-Whaley, Ana Isabel; Vera-Hernández, Arturo; Leija-Salas, Lorenzo

    2018-01-01

    Due to damage of the nervous system, patients experience impediments in their daily life: severe fatigue, tremor or impaired hand dexterity, hemiparesis, or hemiplegia. Surface electromyography (sEMG) signal analysis is used to identify motion; however, standardization of electrode placement and classification of sEMG patterns are major challenges. This paper describes a technique used to acquire sEMG signals for five hand motion patterns from six able-bodied subjects using an array of recording and stimulation electrodes placed on the forearm and its effects over functional electrical stimulation (FES) and volitional sEMG combinations, in order to eventually control a sEMG-driven FES neuroprosthesis for upper limb rehabilitation. A two-part protocol was performed. First, personalized templates to place eight sEMG bipolar channels were designed; with these data, a universal template, called forearm electrode set (FELT), was built. Second, volitional and evoked movements were recorded during FES application. 95% classification accuracy was achieved using two sessions per movement. With the FELT, it was possible to perform FES and sEMG recordings simultaneously. Also, it was possible to extract the volitional and evoked sEMG from the raw signal, which is highly important for closed-loop FES control.

  5. Functional mapping of the pelvic floor and sphincter muscles from high-density surface EMG recordings.

    PubMed

    Peng, Yun; He, Jinbao; Khavari, Rose; Boone, Timothy B; Zhang, Yingchun

    2016-11-01

    Knowledge of the innervation of pelvic floor and sphincter muscles is of great importance to understanding the pathophysiology of female pelvic floor dysfunctions. This report presents our high-density intravaginal and intrarectal electromyography (EMG) probes and a comprehensive innervation zone (IZ) imaging technique based on high-density EMG readings to characterize the IZ distribution. Both intravaginal and intrarectal probes are covered with a high-density surface electromyography electrode grid (8 × 8). Surface EMG signals were acquired in ten healthy women performing maximum voluntary contractions of their pelvic floor. EMG decomposition was performed to separate motor-unit action potentials (MUAPs) and then localize their IZs. High-density surface EMG signals were successfully acquired over the vaginal and rectal surfaces. The propagation patterns of muscle activity were clearly visualized for multiple muscle groups of the pelvic floor and anal sphincter. During each contraction, up to 218 and 456 repetitions of motor units were detected by the vaginal and rectal probes, respectively. MUAPs were separated with their IZs identified at various orientations and depths. The proposed probes are capable of providing a comprehensive mapping of IZs of the pelvic floor and sphincter muscles. They can be employed as diagnostic and preventative tools in clinical practices.

  6. Fractal based modelling and analysis of electromyography (EMG) to identify subtle actions.

    PubMed

    Arjunan, Sridhar P; Kumar, Dinesh K

    2007-01-01

    The paper reports the use of fractal theory and fractal dimension to study the non-linear properties of surface electromyogram (sEMG) and to use these properties to classify subtle hand actions. The paper reports identifying a new feature of the fractal dimension, the bias that has been found to be useful in modelling the muscle activity and of sEMG. Experimental results demonstrate that the feature set consisting of bias values and fractal dimension of the recordings is suitable for classification of sEMG against the different hand gestures. The scatter plots demonstrate the presence of simple relationships of these features against the four hand gestures. The results indicate that there is small inter-experimental variation but large inter-subject variation. This may be due to differences in the size and shape of muscles for different subjects. The possible applications of this research include use in developing prosthetic hands, controlling machines and computers.

  7. Eye contact modulates facial mimicry in 4-month-old infants: An EMG and fNIRS study.

    PubMed

    de Klerk, Carina C J M; Hamilton, Antonia F de C; Southgate, Victoria

    2018-05-16

    Mimicry, the tendency to spontaneously and unconsciously copy others' behaviour, plays an important role in social interactions. It facilitates rapport between strangers, and is flexibly modulated by social signals, such as eye contact. However, little is known about the development of this phenomenon in infancy, and it is unknown whether mimicry is modulated by social signals from early in life. Here we addressed this question by presenting 4-month-old infants with videos of models performing facial actions (e.g., mouth opening, eyebrow raising) and hand actions (e.g., hand opening and closing, finger actions) accompanied by direct or averted gaze, while we measured their facial and hand muscle responses using electromyography to obtain an index of mimicry (Experiment 1). In Experiment 2 the infants observed the same stimuli while we used functional near-infrared spectroscopy to investigate the brain regions involved in modulating mimicry by eye contact. We found that 4-month-olds only showed evidence of mimicry when they observed facial actions accompanied by direct gaze. Experiment 2 suggests that this selective facial mimicry may have been associated with activation over posterior superior temporal sulcus. These findings provide the first demonstration of modulation of mimicry by social signals in young human infants, and suggest that mimicry plays an important role in social interactions from early in life. Copyright © 2018 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  8. Safety of intraoperative electrophysiological monitoring (TES and EMG) for spinal and cranial lesions.

    PubMed

    Gazzeri, Roberto; Faiola, Andrea; Neroni, Massimiliano; Fiore, Claudio; Callovini, Giorgio; Pischedda, Mauro; Galarza, Marcelo

    2013-09-01

    Intraoperative motor evoked potentials (MEP) and electromyography (EMG) monitoring in patients with spinal and cranial lesions is a valuable tool for prevention of postoperative motor deficits. The purpose of this study was to determine whether electrophysiological monitoring during skull base, spinal cord, and spinal surgery might be useful for predicting postoperative motor deterioration. From January 2012 to March 2013, thirty-three consecutive patients were studied using intraoperative monitoring (Nuvasive NV-M5 System) to check the integrity of brainstem, spinal cord, and nerve roots, recording transcranial motor evoked potentials (TcMEPs) and electromyography. Changes in MEPs and EMGs were related to postoperative deficits. Preoperative diagnosis included skull base and brainstem lesions (6 patients), spinal tumors (11 patients), spinal deformity (16 cases). Using TcMEPs and EMG is a practicable and safe method. MEPs are useful in any surgery in which the brainstem and spinal cord are at risk. EMG stimulation helps to identify an optimal trans-psoas entry point for an extreme lateral lumbar interbody fusion (XLIF) approach to protect against potential nerve injury. This neural navigation technique via a surgeon-interpreted interface assists the surgical team in safely removing lesions and accessing the intervertebral disc space for minimally invasive spinal procedures.

  9. Use of uterine electromyography to diagnose term and preterm labor

    PubMed Central

    LUCOVNIK, MIHA; KUON, RUBEN J.; CHAMBLISS, LINDA R.; MANER, WILLIAM L.; SHI, SHAO-QING; SHI, LEILI; BALDUCCI, JAMES; GARFIELD, ROBERT E.

    2011-01-01

    Current methodologies to assess the process of labor, such as tocodynamometry or intrauterine pressure catheters, fetal fibronectin, cervical length measurement and digital cervical examination, have several major drawbacks. They only measure the onset of labor indirectly and do not detect cellular changes characteristic of true labor. Consequently, their predictive values for term or preterm delivery are poor. Uterine contractions are a result of the electrical activity within the myometrium. Measurement of uterine electromyography (EMG) has been shown to detect contractions as accurately as the currently used methods. In addition, changes in cell excitability and coupling required for effective contractions that lead to delivery are reflected in changes of several EMG parameters. Use of uterine EMG can help to identify patients in true labor better than any other method presently employed in the clinic. PMID:21241260

  10. Quality improvement of diagnosis of the electromyography data based on statistical characteristics of the measured signals

    NASA Astrophysics Data System (ADS)

    Selivanova, Karina G.; Avrunin, Oleg G.; Zlepko, Sergii M.; Romanyuk, Sergii O.; Zabolotna, Natalia I.; Kotyra, Andrzej; Komada, Paweł; Smailova, Saule

    2016-09-01

    Research and systematization of motor disorders, taking into account the clinical and neurophysiologic phenomena, are important and actual problem of neurology. The article describes a technique for decomposing surface electromyography (EMG), using Principal Component Analysis. The decomposition is achieved by a set of algorithms that uses a specially developed for analyze EMG. The accuracy was verified by calculation of Mahalanobis distance and Probability error.

  11. Guiding Intramuscular Diaphragm Injections Using Real-time Ultrasound & Electromyography

    PubMed Central

    Sarwal, Aarti; Cartwright, Michael S.; Mitchell, Erin; Williams, Koudy; Walker, Francis O.; Childers, Martin K.

    2014-01-01

    Introduction We describe a unique method that combines ultrasound and electromyography to guide intramuscular diaphragm injections in anesthetized large animals. Methods Ultrasound was used to visualize the diaphragm on each side of spontaneously breathing, anesthetized beagle dogs and cynomolgus macaques. An electromyography needle was introduced and directed by ultrasound to confirm that the needle entered the muscular portion of the diaphragm, and methylene blue was injected. Injection accuracy was confirmed upon necropsy by tracking the spread of methylene blue. Results All methylene blue injections were confirmed to have been placed appropriately into the diaphragm. Conclusions This study demonstrates the feasibility and accuracy of using ultrasound and EMG to guide injections and to reduce complications associated with conventional blind techniques. Ultrasound guidance can be used for clinical electromyography of the diaphragm. Future applications may include targeted diaphragm injections with gene replacement therapy in neuromuscular diseases. PMID:25354257

  12. Biomechanical Correlates of Surface Electromyography Signals Obtained during Swallowing by Healthy Adults

    ERIC Educational Resources Information Center

    Crary, Michael A.; Carnaby (Mann), Giselle D.; Groher, Michael E.

    2006-01-01

    Purpose: The purpose of this study was to describe biomechanical correlates of the surface electromyographic signal obtained during swallowing by healthy adult volunteers. Method: Seventeen healthy adults were evaluated with simultaneous videofluoroscopy and surface electromyography (sEMG) while swallowing 5 mL of liquid barium sulfate. Three…

  13. History dependence of the EMG-torque relationship.

    PubMed

    Paquin, James; Power, Geoffrey A

    2018-05-28

    The influence of active lengthening (residual force enhancement: RFE) and shortening (force depression: FD) on the electromyography (EMG)-torque relationship was investigated by matching torque and activation at 20%, 40%, 60%, 80% and 100% maximal voluntary contraction (MVC). Sixteen males performed lengthening and shortening contractions of the dorsiflexors over 25° into an isometric steady-state. There was 5% greater torque, with no change in agonist EMG during the RFE condition as compared to the isometric condition. Sub-maximally, in the force enhanced state, there was less agonist EMG during the torque clamp at all intensities relative to isometric, and greater torque during the activation clamps relative to isometric was observed across all intensities except 20% MVC. During the FD state compared to isometric, there was less torque produced during MVC (∼15%) with no change in agonist EMG. Sub-maximally, in the FD state, there was greater agonist EMG during the torque clamp and less torque during the activation clamp relative to the isometric condition across all intensities. The EMG-torque relationship was bilinear for all contraction types but was shifted to the left and right for FD and RFE, respectively as compared with isometric, indicating altered neuromuscular activation strategies in the history-dependent states of RFE and FD. Copyright © 2018. Published by Elsevier Ltd.

  14. Automatic analysis and classification of surface electromyography.

    PubMed

    Abou-Chadi, F E; Nashar, A; Saad, M

    2001-01-01

    In this paper, parametric modeling of surface electromyography (EMG) algorithms that facilitates automatic SEMG feature extraction and artificial neural networks (ANN) are combined for providing an integrated system for the automatic analysis and diagnosis of myopathic disorders. Three paradigms of ANN were investigated: the multilayer backpropagation algorithm, the self-organizing feature map algorithm and a probabilistic neural network model. The performance of the three classifiers was compared with that of the old Fisher linear discriminant (FLD) classifiers. The results have shown that the three ANN models give higher performance. The percentage of correct classification reaches 90%. Poorer diagnostic performance was obtained from the FLD classifier. The system presented here indicates that surface EMG, when properly processed, can be used to provide the physician with a diagnostic assist device.

  15. EMG amplifier with wireless data transmission

    NASA Astrophysics Data System (ADS)

    Kowalski, Grzegorz; Wildner, Krzysztof

    2017-08-01

    Wireless medical diagnostics is a trend in modern technology used in medicine. This paper presents a concept of realization, architecture of hardware and software implementation of an elecromyography signal (EMG) amplifier with wireless data transmission. This amplifier consists of three components: analogue processing of bioelectric signal module, micro-controller circuit and an application enabling data acquisition via a personal computer. The analogue bioelectric signal processing circuit receives electromyography signals from the skin surface, followed by initial analogue processing and preparation of the signals for further digital processing. The second module is a micro-controller circuit designed to wirelessly transmit the electromyography signals from the analogue signal converter to a personal computer. Its purpose is to eliminate the need for wired connections between the patient and the data logging device. The third block is a computer application designed to display the transmitted electromyography signals, as well as data capture and analysis. Its purpose is to provide a graphical representation of the collected data. The entire device has been thoroughly tested to ensure proper functioning. In use, the device displayed the captured electromyography signal from the arm of the patient. Amplitude- frequency characteristics were set in order to investigate the bandwidth and the overall gain of the device.

  16. Selectivity of conventional electrodes for recording motor evoked potentials: An investigation with high-density surface electromyography.

    PubMed

    Gallina, Alessio; Peters, Sue; Neva, Jason L; Boyd, Lara A; Garland, S Jayne

    2017-06-01

    The objective of this study was to determine whether motor evoked potentials (MEPs) elicited with transcranial magnetic stimulation and measured with conventional bipolar electromyography (EMG) are influenced by crosstalk from non-target muscles. MEPs were recorded in healthy participants using conventional EMG electrodes placed over the extensor carpi radialis muscle (ECR) and high-density surface EMG (HDsEMG). Fifty MEPs at 120% resting and active motor threshold were recorded. To determine the contribution of ECR to the MEPs, the amplitude distribution across HDsEMG channels was correlated with EMG activity recorded during a wrist extension task. Whereas the conventional EMG identified MEPs from ECR in >90% of the stimulations, HDsEMG revealed that spatial amplitude distribution representative of ECR activation was observed less frequently at rest than while holding a contraction (P < 0.001). MEPs recorded with conventional EMG may contain crosstalk from non-target muscles, especially when the stimulation is applied at rest. Muscle Nerve 55: 828-834, 2017. © 2016 Wiley Periodicals, Inc.

  17. Features extraction of EMG signal using time domain analysis for arm rehabilitation device

    NASA Astrophysics Data System (ADS)

    Jali, Mohd Hafiz; Ibrahim, Iffah Masturah; Sulaima, Mohamad Fani; Bukhari, W. M.; Izzuddin, Tarmizi Ahmad; Nasir, Mohamad Na'im

    2015-05-01

    Rehabilitation device is used as an exoskeleton for people who had failure of their limb. Arm rehabilitation device may help the rehab program whom suffers from arm disability. The device that is used to facilitate the tasks of the program should improve the electrical activity in the motor unit and minimize the mental effort of the user. Electromyography (EMG) is the techniques to analyze the presence of electrical activity in musculoskeletal systems. The electrical activity in muscles of disable person is failed to contract the muscle for movements. In order to prevent the muscles from paralysis becomes spasticity, the force of movements should minimize the mental efforts. Therefore, the rehabilitation device should analyze the surface EMG signal of normal people that can be implemented to the device. The signal is collected according to procedure of surface electromyography for non-invasive assessment of muscles (SENIAM). The EMG signal is implemented to set the movements' pattern of the arm rehabilitation device. The filtered EMG signal was extracted for features of Standard Deviation (STD), Mean Absolute Value (MAV) and Root Mean Square (RMS) in time-domain. The extraction of EMG data is important to have the reduced vector in the signal features with less of error. In order to determine the best features for any movements, several trials of extraction methods are used by determining the features with less of errors. The accurate features can be use for future works of rehabilitation control in real-time.

  18. Surface EMG crosstalk during phasic involuntary muscle activation in the nociceptive withdrawal reflex.

    PubMed

    Frahm, Ken S; Jensen, Michael B; Farina, Dario; Andersen, Ole K

    2012-08-01

    The human nociceptive withdrawal reflex is typically assessed using surface electromyography (sEMG). Based on sEMG, the reflex receptive field (RRF) can be mapped. However, EMG crosstalk can cause erroneous results in the RRF determination. Single differential (SD) vs. double differential (DD) surface EMG were evaluated. Different electrode areas and inter-electrode-distances (IED) were evaluated. The reflexes were elicited by electrical stimulation of the sole of the foot. EMG was obtained from both tibialis anterior (TA) and soleus (SOL) using both surface and intramuscular EMG (iEMG). The amount of crosstalk was significantly higher in SD recordings than in DD recordings (P < 0.05). Crosstalk increased when electrode measuring area increased (P < 0.05) and when IED increased (P < 0.05). Reflex detection sensitivity decreases with increasing measuring area and increasing IED. These results stress that for determination of RRF and similar tasks, DD recordings should be applied. Copyright © 2012 Wiley Periodicals, Inc.

  19. Emg Amplitude Estimators Based on Probability Distribution for Muscle-Computer Interface

    NASA Astrophysics Data System (ADS)

    Phinyomark, Angkoon; Quaine, Franck; Laurillau, Yann; Thongpanja, Sirinee; Limsakul, Chusak; Phukpattaranont, Pornchai

    To develop an advanced muscle-computer interface (MCI) based on surface electromyography (EMG) signal, the amplitude estimations of muscle activities, i.e., root mean square (RMS) and mean absolute value (MAV) are widely used as a convenient and accurate input for a recognition system. Their classification performance is comparable to advanced and high computational time-scale methods, i.e., the wavelet transform. However, the signal-to-noise-ratio (SNR) performance of RMS and MAV depends on a probability density function (PDF) of EMG signals, i.e., Gaussian or Laplacian. The PDF of upper-limb motions associated with EMG signals is still not clear, especially for dynamic muscle contraction. In this paper, the EMG PDF is investigated based on surface EMG recorded during finger, hand, wrist and forearm motions. The results show that on average the experimental EMG PDF is closer to a Laplacian density, particularly for male subject and flexor muscle. For the amplitude estimation, MAV has a higher SNR, defined as the mean feature divided by its fluctuation, than RMS. Due to a same discrimination of RMS and MAV in feature space, MAV is recommended to be used as a suitable EMG amplitude estimator for EMG-based MCIs.

  20. The use of intraoperative triggered electromyography to detect misplaced pedicle screws: a systematic review and meta-analysis.

    PubMed

    Mikula, Anthony L; Williams, Seth K; Anderson, Paul A

    2016-04-01

    Insertion of instruments or implants into the spine carries a risk for injury to neural tissue. Triggered electromyography (tEMG) is an intraoperative neuromonitoring technique that involves electrical stimulation of a tool or screw and subsequent measurement of muscle action potentials from myotomes innervated by nerve roots near the stimulated instrument. The authors of this study sought to determine the ability of tEMG to detect misplaced pedicle screws (PSs). The authors searched the U.S. National Library of Medicine, the Web of Science Core Collection database, and the Cochrane Central Register of Controlled Trials for PS studies. A meta-analysis of these studies was performed on a per-screw basis to determine the ability of tEMG to detect misplaced PSs. Sensitivity, specificity, and receiver operating characteristic (ROC) area under the curve (AUC) were calculated overall and in subgroups. Twenty-six studies were included in the systematic review. The authors analyzed 18 studies in which tEMG was used during PS placement in the meta-analysis, representing data from 2932 patients and 15,065 screws. The overall sensitivity of tEMG for detecting misplaced PSs was 0.78, and the specificity was 0.94. The overall ROC AUC was 0.96. A tEMG current threshold of 10-12 mA (ROC AUC 0.99) and a pulse duration of 300 µsec (ROC AUC 0.97) provided the most accurate testing parameters for detecting misplaced screws. Screws most accurately conducted EMG signals (ROC AUC 0.98). Triggered electromyography has very high specificity but only fair sensitivity for detecting malpositioned PSs.

  1. Magnetic resonance imaging and electromyography as indexes of muscle function

    NASA Technical Reports Server (NTRS)

    Adams, Gregory R.; Duvoisin, Marc R.; Dudley, Gary A.

    1992-01-01

    A hypothesis is tested that exercise-induced magnetic resonance (MR) contrast shifts would relate to electromyography (EMG) amplitude if both measures reflect muscle use during exercise. Both magnetic resonance images (MRI) and EMG data were obtained for separate eccentric (ECC) and cocentric (CON) exercise of increasing intensity for seven subjects 30-32 yr old. CON and ECC actions caused increased integrated EMG (IEMG) and T2 values which were strongly related with relative resistance. The rate of increase and absolute value of both T2 and IEMG were found to be greater for CON than for ECC actions. For both actions IEMG and T2 were correlated. Data obtained suggest that surface IEMG accurately reflects the contractile behavior of muscle and exercise-induced increases in MRI T2 values reflect certain processes that scale with muscle use.

  2. Multi-modal myocontrol: Testing combined force- and electromyography.

    PubMed

    Nowak, Markus; Eiband, Thomas; Castellini, Claudio

    2017-07-01

    Myocontrol, that is control of prostheses using bodily signals, has proved in the decades to be a surprisingly hard problem for the scientific community of assistive and rehabilitation robotics. In particular, traditional surface electromyography (sEMG) seems to be no longer enough to guarantee dexterity (i.e., control over several degrees of freedom) and, most importantly, reliability. Multi-modal myocontrol is concerned with the idea of using novel signal gathering techniques as a replacement of, or alongside, sEMG, to provide high-density and diverse signals to improve dexterity and make the control more reliable. In this paper we present an offline and online assessment of multi-modal sEMG and force myography (FMG) targeted at hand and wrist myocontrol. A total number of twenty sEMG and FMG sensors were used simultaneously, in several combined configurations, to predict opening/closing of the hand and activation of two degrees of freedom of the wrist of ten intact subjects. The analysis was targeted at determining the optimal sensor combination and control parameters; the experimental results indicate that sEMG sensors alone perform worst, yielding a nRMSE of 9.1%, while mixing FMG and sEMG or using FMG only reduces the nRMSE to 5.2-6.6%. To validate these results, we engaged the subject with median performance in an online goal-reaching task. Analysis of this further experiment reveals that the online behaviour is similar to the offline one.

  3. Correlations between the clinical, histological and neurophysiological examinations in patients before and after parotid gland tumor surgery: verification of facial nerve transmission.

    PubMed

    Wiertel-Krawczuk, Agnieszka; Huber, Juliusz; Wojtysiak, Magdalena; Golusiński, Wojciech; Pieńkowski, Piotr; Golusiński, Paweł

    2015-05-01

    Parotid gland tumor surgery sometimes leads to facial nerve paralysis. Malignant more than benign tumors determine nerve function preoperatively, while postoperative observations based on clinical, histological and neurophysiological studies have not been reported in detail. The aims of this pilot study were evaluation and correlations of histological properties of tumor (its size and location) and clinical and neurophysiological assessment of facial nerve function pre- and post-operatively (1 and 6 months). Comparative studies included 17 patients with benign (n = 13) and malignant (n = 4) tumors. Clinical assessment was based on House-Brackmann scale (H-B), neurophysiological diagnostics included facial electroneurography [ENG, compound muscle action potential (CMAP)], mimetic muscle electromyography (EMG) and blink-reflex examinations (BR). Mainly grade I of H-B was recorded both pre- (n = 13) and post-operatively (n = 12) in patients with small (1.5-2.4 cm) benign tumors located in superficial lobes. Patients with medium size (2.5-3.4 cm) malignant tumors in both lobes were scored at grade I (n = 2) and III (n = 2) pre- and mainly VI (n = 4) post-operatively. CMAP amplitudes after stimulation of mandibular marginal branch were reduced at about 25 % in patients with benign tumors after surgery. In the cases of malignant tumors CMAPs were not recorded following stimulation of any branch. A similar trend was found for BR results. H-B and ENG results revealed positive correlations between the type of tumor and surgery with facial nerve function. Neurophysiological studies detected clinically silent facial nerve neuropathy of mandibular marginal branch in postoperative period. Needle EMG, ENG and BR examinations allow for the evaluation of face muscles reinnervation and facial nerve regeneration.

  4. Surface electromyography in orthodontics – a literature review

    PubMed Central

    WoŸniak, Krzysztof; Piątkowska, Dagmara; Lipski, Mariusz; Mehr, Katarzyna

    2013-01-01

    Electromyography is the most objective and reliable technique for evaluating muscle function and efficiency by detecting their electrical potentials. It makes it possible to assess the extent and duration of muscle activity. The main aim of surface electromyography is to detect signals from many muscle fibers in the area of the detecting surface electrodes. These signals consist of a weighted summation of the spatial and temporal activity of many motor units. Hence, the analysis of the recordings is restricted to an assessment of general muscle activity, the cooperation of different muscles, and the variability of their activity over time. This study presents the main assumptions in the assessment of electrical muscle activity through the use of surface electromyography, along with its limitations and possibilities for further use in many areas of orthodontics. The main clinical uses of sEMG include the diagnostics and therapy of temporomandibular joint disorders, an assessment of the extent of stomatognathic system dysfunctions in subjects with malocclusion, and the monitoring of orthodontic therapies. PMID:23722255

  5. Epidermal electronics for electromyography: An application to swallowing therapy.

    PubMed

    Constantinescu, Gabriela; Jeong, Jae-Woong; Li, Xinda; Scott, Dylan K; Jang, Kyung-In; Chung, Hyun-Joong; Rogers, John A; Rieger, Jana

    2016-08-01

    Head and neck cancer treatment alters the anatomy and physiology of patients. Resulting swallowing difficulties can lead to serious health concerns. Surface electromyography (sEMG) is used as an adjuvant to swallowing therapy exercises. sEMG signal collected from the area under the chin provides visual biofeedback from muscle contractions and is used to help patients perform exercises correctly. However, conventional sEMG adhesive pads are relatively thick and difficult to effectively adhere to a patient's altered chin anatomy, potentially leading to poor signal acquisition in this population. Here, the emerging technology of epidermal electronics is introduced, where ultra-thin geometry allows for close contouring of the chin. The two objectives of this study were to (1) assess the potential of epidermal electronics technology for use with swallowing therapy and (2) assess the significance of the reference electrode placement. This study showed comparative signals between the new epidermal sEMG patch and the conventional adhesive patches used by clinicians. Furthermore, an integrated reference yielded optimal signal for clinical use; this configuration was more robust to head movements than when an external reference was used. Improvements for future iterations of epidermal sEMG patches specific to day-to-day clinical use are suggested. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  6. Improving Functional Magnetic Resonance Imaging Motor Studies Through Simultaneous Electromyography Recordings

    PubMed Central

    MacIntosh, Bradley J.; Baker, S. Nicole; Mraz, Richard; Ives, John R.; Martel, Anne L.; McIlroy, William E.; Graham, Simon J.

    2016-01-01

    Specially designed optoelectronic and data postprocessing methods are described that permit electromyography (EMG) of muscle activity simultaneous with functional MRI (fMRI). Hardware characterization and validation included simultaneous EMG and event-related fMRI in 17 healthy participants during either ankle (n = 12), index finger (n = 3), or wrist (n = 2) contractions cued by visual stimuli. Principal component analysis (PCA) and independent component analysis (ICA) were evaluated for their ability to remove residual fMRI gradient-induced signal contamination in EMG data. Contractions of ankle tibialis anterior and index finger abductor were clearly distinguishable, although observing contractions from the wrist flexors proved more challenging. To demonstrate the potential utility of simultaneous EMG and fMRI, data from the ankle experiments were analyzed using two approaches: 1) assuming contractions coincided precisely with visual cues, and 2) using EMG to time the onset and offset of muscle contraction precisely for each participant. Both methods produced complementary activation maps, although the EMG-guided approach recovered more active brain voxels and revealed activity better in the basal ganglia and cerebellum. Furthermore, numerical simulations confirmed that precise knowledge of behavioral responses, such as those provided by EMG, are much more important for event-related experimental designs compared to block designs. This simultaneous EMG and fMRI methodology has important applications where the amplitude or timing of motor output is impaired, such as after stroke. PMID:17133382

  7. The role of cranial and thoracic electromyography within diagnostic criteria for amyotrophic lateral sclerosis.

    PubMed

    Jenkins, Thomas M; Alix, James J P; Kandler, Rosalind H; Shaw, Pamela J; McDermott, Christopher J

    2016-09-01

    The contribution of cranial and thoracic region electromyography (EMG) to diagnostic criteria for amyotrophic lateral sclerosis (ALS) has not been evaluated. Clinical and EMG data from each craniospinal region were retrospectively assessed in 470 patients; 214 had ALS. Changes to diagnostic classification in Awaji-Shima and revised El Escorial criteria after withdrawal of cranial/thoracic EMG data were ascertained. Sensitivity for lower motor neuron involvement in ALS was highest in the cervical/lumbar regions; specificity was highest in cranial/thoracic regions. Cranial EMG contributed to definite/probable Awaji-Shima categorization in 1.4% of patients. Thoracic EMG made no contribution. For revised El Escorial criteria, cranial and thoracic data reclassified 1% and 5% of patients, respectively. Cranial EMG data make small contributions to both criteria, whereas thoracic data contribute only to the revised El Escorial criteria. However, cranial and thoracic region abnormalities are specific in ALS. Consideration should be given to allowing greater diagnostic contribution from thoracic EMG. Muscle Nerve 54: 378-385, 2016. © 2016 Wiley Periodicals, Inc.

  8. The Advantages of Normalizing Electromyography to Ballistic Rather than Isometric or Isokinetic Tasks.

    PubMed

    Suydam, Stephen M; Manal, Kurt; Buchanan, Thomas S

    2017-07-01

    Isometric tasks have been a standard for electromyography (EMG) normalization stemming from anatomic and physiologic stability observed during contraction. Ballistic dynamic tasks have the benefit of eliciting maximum EMG signals for normalization, despite having the potential for greater signal variability. It is the purpose of this study to compare maximum voluntary isometric contraction (MVIC) to nonisometric tasks with increasing degrees of extrinsic variability, ie, joint range of motion, velocity, rate of contraction, etc., to determine if the ballistic tasks, which elicit larger peak EMG signals, are more reliable than the constrained MVIC. Fifteen subjects performed MVIC, isokinetic, maximum countermovement jump, and sprint tasks while EMG was collected from 9 muscles in the quadriceps, hamstrings, and lower leg. The results revealed the unconstrained ballistic tasks were more reliable compared to the constrained MVIC and isokinetic tasks for all triceps surae muscles. The EMG from sprinting was more reliable than the constrained cases for both the hamstrings and vasti. The most reliable EMG signals occurred when the body was permitted its natural, unconstrained motion. These results suggest that EMG is best normalized using ballistic tasks to provide the greatest within-subject reliability, which beneficially yield maximum EMG values.

  9. Interpreting Signal Amplitudes in Surface Electromyography Studies in Sport and Rehabilitation Sciences

    PubMed Central

    Vigotsky, Andrew D.; Halperin, Israel; Lehman, Gregory J.; Trajano, Gabriel S.; Vieira, Taian M.

    2018-01-01

    Surface electromyography (sEMG) is a popular research tool in sport and rehabilitation sciences. Common study designs include the comparison of sEMG amplitudes collected from different muscles as participants perform various exercises and techniques under different loads. Based on such comparisons, researchers attempt to draw conclusions concerning the neuro- and electrophysiological underpinning of force production and hypothesize about possible longitudinal adaptations, such as strength and hypertrophy. However, such conclusions are frequently unsubstantiated and unwarranted. Hence, the goal of this review is to discuss what can and cannot be inferred from comparative research designs as it pertains to both the acute and longitudinal outcomes. General methodological recommendations are made, gaps in the literature are identified, and lines for future research to help improve the applicability of sEMG are suggested. PMID:29354060

  10. EMG normalization to study muscle activation in cycling.

    PubMed

    Rouffet, David M; Hautier, Christophe A

    2008-10-01

    The value of electromyography (EMG) is sensitive to many physiological and non-physiological factors. The purpose of the present study was to determine if the torque-velocity test (T-V) can be used to normalize EMG signals into a framework of biological significance. Peak EMG amplitude of gluteus maximus (GMAX), vastus lateralis (VL), rectus femoris (RF), biceps femoris long head (BF), gastrocnemius medialis (GAS) and soleus (SOL) was calculated for nine subjects during isometric maximal voluntary contractions (IMVC) and torque-velocity bicycling tests (T-V). Then, the reference EMG signals obtained from IMVC and T-V bicycling tests were used to normalize the amplitude of the EMG signals collected for 15 different submaximal pedaling conditions. The results of this study showed that the repeatability of the measurements between IMVC (from 10% to 23%) and T-V (from 8% to 20%) was comparable. The amplitude of the peak EMG of VL was 99+/-43% higher (p<0.001) when measured during T-V. Moreover, the inter-individual variability of the EMG patterns calculated for submaximal cycling exercises differed significantly when using T-V bicycling normalization method (GMAX: 0.33+/-0.16 vs. 1.09+/-0.04, VL: 0.07+/-0.02 vs. 0.64+/-0.14, SOL: 0.07+/-0.03 vs. 1.00+/-0.07, RF: 1.21+/-0.20 vs. 0.92+/-0.13, BF: 1.47+/-0.47 vs. 0.84+/-0.11). It was concluded that T-V bicycling test offers the advantage to be less time and energy-consuming and to be as repeatable as IMVC tests to measure peak EMG amplitude. Furthermore, this normalization method avoids the impact of non-physiological factors on the amplitude of the EMG signals so that it allows quantifying better the activation level of lower limb muscles and the variability of the EMG patterns during submaximal bicycling exercises.

  11. EMG-based speech recognition using hidden markov models with global control variables.

    PubMed

    Lee, Ki-Seung

    2008-03-01

    It is well known that a strong relationship exists between human voices and the movement of articulatory facial muscles. In this paper, we utilize this knowledge to implement an automatic speech recognition scheme which uses solely surface electromyogram (EMG) signals. The sequence of EMG signals for each word is modelled by a hidden Markov model (HMM) framework. The main objective of the work involves building a model for state observation density when multichannel observation sequences are given. The proposed model reflects the dependencies between each of the EMG signals, which are described by introducing a global control variable. We also develop an efficient model training method, based on a maximum likelihood criterion. In a preliminary study, 60 isolated words were used as recognition variables. EMG signals were acquired from three articulatory facial muscles. The findings indicate that such a system may have the capacity to recognize speech signals with an accuracy of up to 87.07%, which is superior to the independent probabilistic model.

  12. [Surface electromyography signal classification using gray system theory].

    PubMed

    Xie, Hongbo; Ma, Congbin; Wang, Zhizhong; Huang, Hai

    2004-12-01

    A new method based on gray correlation was introduced to improve the identification rate in artificial limb. The electromyography (EMG) signal was first transformed into time-frequency domain by wavelet transform. Singular value decomposition (SVD) was then used to extract feature vector from the wavelet coefficient for pattern recognition. The decision was made according to the maximum gray correlation coefficient. Compared with neural network recognition, this robust method has an almost equivalent recognition rate but much lower computation costs and less training samples.

  13. Reliability of quadriceps surface electromyography measurements is improved by two vs. single site recordings.

    PubMed

    Balshaw, T G; Fry, A; Maden-Wilkinson, T M; Kong, P W; Folland, J P

    2017-06-01

    The reliability of surface electromyography (sEMG) is typically modest even with rigorous methods, and therefore further improvements in sEMG reliability are desirable. This study compared the between-session reliability (both within participant absolute reliability and between-participant relative reliability) of sEMG amplitude from single vs. average of two distinct recording sites, for individual muscle (IM) and whole quadriceps (WQ) measures during voluntary and evoked contractions. Healthy males (n = 20) performed unilateral isometric knee extension contractions: voluntary maximum and submaximum (60%), as well as evoked twitch contractions on two separate days. sEMG was recorded from two distinct sites on each superficial quadriceps muscle. Averaging two recording sites vs. using single site measures improved reliability for IM and WQ measurements during voluntary (16-26% reduction in within-participant coefficient of variation, CV W ) and evoked contractions (40-56% reduction in CV W ). For sEMG measurements from large muscles, averaging the recording of two distinct sites is recommended as it improves within-participant reliability. This improved sensitivity has application to clinical and research measurement of sEMG amplitude.

  14. Improving functional magnetic resonance imaging motor studies through simultaneous electromyography recordings.

    PubMed

    MacIntosh, Bradley J; Baker, S Nicole; Mraz, Richard; Ives, John R; Martel, Anne L; McIlroy, William E; Graham, Simon J

    2007-09-01

    Specially designed optoelectronic and data postprocessing methods are described that permit electromyography (EMG) of muscle activity simultaneous with functional MRI (fMRI). Hardware characterization and validation included simultaneous EMG and event-related fMRI in 17 healthy participants during either ankle (n = 12), index finger (n = 3), or wrist (n = 2) contractions cued by visual stimuli. Principal component analysis (PCA) and independent component analysis (ICA) were evaluated for their ability to remove residual fMRI gradient-induced signal contamination in EMG data. Contractions of ankle tibialis anterior and index finger abductor were clearly distinguishable, although observing contractions from the wrist flexors proved more challenging. To demonstrate the potential utility of simultaneous EMG and fMRI, data from the ankle experiments were analyzed using two approaches: 1) assuming contractions coincided precisely with visual cues, and 2) using EMG to time the onset and offset of muscle contraction precisely for each participant. Both methods produced complementary activation maps, although the EMG-guided approach recovered more active brain voxels and revealed activity better in the basal ganglia and cerebellum. Furthermore, numerical simulations confirmed that precise knowledge of behavioral responses, such as those provided by EMG, are much more important for event-related experimental designs compared to block designs. This simultaneous EMG and fMRI methodology has important applications where the amplitude or timing of motor output is impaired, such as after stroke. (c) 2006 Wiley-Liss, Inc.

  15. An EMG-CT method using multiple surface electrodes in the forearm.

    PubMed

    Nakajima, Yasuhiro; Keeratihattayakorn, Saran; Yoshinari, Satoshi; Tadano, Shigeru

    2014-12-01

    Electromyography computed tomography (EMG-CT) method is proposed for visualizing the individual muscle activities in the human forearm. An EMG conduction model was formulated for reverse-estimation of muscle activities using EMG signals obtained with multi surface electrodes. The optimization process was calculated using sequential quadratic programming by comparing the estimated EMG values from the model with the measured values. The individual muscle activities in the deep region were estimated and used to produce an EMG tomographic image. For validation of the method, isometric contractions of finger muscles were examined for three subjects, applying a flexion load (4.9, 7.4 and 9.8 N) to the proximal interphalangeal joint of the middle finger. EMG signals in the forearm were recorded during the tasks using multiple surface electrodes, which were bound around the subject's forearm. The EMG-CT method illustrates the distribution of muscle activities within the forearm. The change in amplitude and area of activated muscles can be observed. The normalized muscle activities of all three subjects appear to increase monotonically with increases in the load. Kinesiologically, this method was able to estimate individual muscle activation values and could provide a novel tool for studying hand function and development of an examination for evaluating rehabilitation. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Three-Way Analysis of Spectrospatial Electromyography Data: Classification and Interpretation

    PubMed Central

    Kauppi, Jukka-Pekka; Hahne, Janne; Müller, Klaus-Robert; Hyvärinen, Aapo

    2015-01-01

    Classifying multivariate electromyography (EMG) data is an important problem in prosthesis control as well as in neurophysiological studies and diagnosis. With modern high-density EMG sensor technology, it is possible to capture the rich spectrospatial structure of the myoelectric activity. We hypothesize that multi-way machine learning methods can efficiently utilize this structure in classification as well as reveal interesting patterns in it. To this end, we investigate the suitability of existing three-way classification methods to EMG-based hand movement classification in spectrospatial domain, as well as extend these methods by sparsification and regularization. We propose to use Fourier-domain independent component analysis as preprocessing to improve classification and interpretability of the results. In high-density EMG experiments on hand movements across 10 subjects, three-way classification yielded higher average performance compared with state-of-the art classification based on temporal features, suggesting that the three-way analysis approach can efficiently utilize detailed spectrospatial information of high-density EMG. Phase and amplitude patterns of features selected by the classifier in finger-movement data were found to be consistent with known physiology. Thus, our approach can accurately resolve hand and finger movements on the basis of detailed spectrospatial information, and at the same time allows for physiological interpretation of the results. PMID:26039100

  17. Effects of Patient-Controlled Epidural Analgesia on Uterine Electromyography During Spontaneous Onset of Labor in Term Nulliparous Women.

    PubMed

    Ye, Yuanjuan; Song, Xingrong; Liu, Lei; Shi, Shao-Qing; Garfield, Robert E; Zhang, Guozheng; Liu, Huishu

    2015-11-01

    To investigate the effect of patient-controlled epidural analgesia (PCEA) on uterine electromyography (EMG) activity in term pregnant women during labor. Nulliparous pregnant women in spontaneous term labor (N = 30) were enrolled (PCEA group, n = 20 and control group, n = 10). Five time periods (30 minutes each) were defined for noninvasive abdominal recordings and analysis of uterine EMG activity, that is, period I: before PCEA treatment with 2-cm cervical dilation; periods II to IV: each period successively at 30, 60, and 120 minutes after PCEA; and period V: second stage of labor with cervix at 10 cm dilation. Control patients without PCEA were monitored during the same times. The number of bursts/30 min, power density spectrum peak frequency, mean amplitude, and duration of uterine EMG bursts were measured to assess uterine EMG activity. Maternal, fetal, and labor characteristics were also recorded. Data were analyzed by analysis of variance followed by other tests. Electromyography parameters are significantly lower (P < .001) after PCEA (periods II to IV) compared to controls but similar between groups by period V (P > .05). Also, patients with PCEA have a slower rate of cervical dilation (P < .003, period IV only) and longer labor in both stage 1 and stage 2 (P < .05). All patients have similar (P > .05) positive labor outcomes. Patient-controlled epidural analgesia initially suppresses uterine EMG and slows cervical dilation thereby prolonging labor. However, the EMG activity recovers with labor progress with no effects on delivery outcomes. © The Author(s) 2015.

  18. Exploration of Force Myography and surface Electromyography in hand gesture classification.

    PubMed

    Jiang, Xianta; Merhi, Lukas-Karim; Xiao, Zhen Gang; Menon, Carlo

    2017-03-01

    Whereas pressure sensors increasingly have received attention as a non-invasive interface for hand gesture recognition, their performance has not been comprehensively evaluated. This work examined the performance of hand gesture classification using Force Myography (FMG) and surface Electromyography (sEMG) technologies by performing 3 sets of 48 hand gestures using a prototyped FMG band and an array of commercial sEMG sensors worn both on the wrist and forearm simultaneously. The results show that the FMG band achieved classification accuracies as good as the high quality, commercially available, sEMG system on both wrist and forearm positions; specifically, by only using 8 Force Sensitive Resisters (FSRs), the FMG band achieved accuracies of 91.2% and 83.5% in classifying the 48 hand gestures in cross-validation and cross-trial evaluations, which were higher than those of sEMG (84.6% and 79.1%). By using all 16 FSRs on the band, our device achieved high accuracies of 96.7% and 89.4% in cross-validation and cross-trial evaluations. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  19. A Rodent Model of Dynamic Facial Reanimation Using Functional Electrical Stimulation

    PubMed Central

    Attiah, Mark A.; de Vries, Julius; Richardson, Andrew G.; Lucas, Timothy H.

    2017-01-01

    Facial paralysis can be a devastating condition, causing disfiguring facial droop, slurred speech, eye dryness, scarring and blindness. This study investigated the utility of closed-loop functional electric stimulation (FES) for reanimating paralyzed facial muscles in a quantitative rodent model. The right buccal and marginal mandibular branches of the rat facial nerve were transected for selective, unilateral paralysis of whisker muscles. Microwire electrodes were implanted bilaterally into the facial musculature for FES and electromyographic (EMG) recording. With the rats awake and head-fixed, whisker trajectories were tracked bilaterally with optical micrometers. First, the relationship between EMG and volitional whisker movement was quantified on the intact side of the face. Second, the effect of FES on whisker trajectories was quantified on the paralyzed side. Third, closed-loop experiments were performed in which the EMG signal on the intact side triggered FES on the paralyzed side to restore symmetric whisking. The results demonstrate a novel in vivo platform for developing control strategies for neuromuscular facial prostheses. PMID:28424583

  20. EMG Processing Based Measures of Fatigue Assessment during Manual Lifting.

    PubMed

    Shair, E F; Ahmad, S A; Marhaban, M H; Mohd Tamrin, S B; Abdullah, A R

    2017-01-01

    Manual lifting is one of the common practices used in the industries to transport or move objects to a desired place. Nowadays, even though mechanized equipment is widely available, manual lifting is still considered as an essential way to perform material handling task. Improper lifting strategies may contribute to musculoskeletal disorders (MSDs), where overexertion contributes as the highest factor. To overcome this problem, electromyography (EMG) signal is used to monitor the workers' muscle condition and to find maximum lifting load, lifting height and number of repetitions that the workers are able to handle before experiencing fatigue to avoid overexertion. Past researchers have introduced several EMG processing techniques and different EMG features that represent fatigue indices in time, frequency, and time-frequency domain. The impact of EMG processing based measures in fatigue assessment during manual lifting are reviewed in this paper. It is believed that this paper will greatly benefit researchers who need a bird's eye view of the biosignal processing which are currently available, thus determining the best possible techniques for lifting applications.

  1. EMG Processing Based Measures of Fatigue Assessment during Manual Lifting

    PubMed Central

    Marhaban, M. H.; Abdullah, A. R.

    2017-01-01

    Manual lifting is one of the common practices used in the industries to transport or move objects to a desired place. Nowadays, even though mechanized equipment is widely available, manual lifting is still considered as an essential way to perform material handling task. Improper lifting strategies may contribute to musculoskeletal disorders (MSDs), where overexertion contributes as the highest factor. To overcome this problem, electromyography (EMG) signal is used to monitor the workers' muscle condition and to find maximum lifting load, lifting height and number of repetitions that the workers are able to handle before experiencing fatigue to avoid overexertion. Past researchers have introduced several EMG processing techniques and different EMG features that represent fatigue indices in time, frequency, and time-frequency domain. The impact of EMG processing based measures in fatigue assessment during manual lifting are reviewed in this paper. It is believed that this paper will greatly benefit researchers who need a bird's eye view of the biosignal processing which are currently available, thus determining the best possible techniques for lifting applications. PMID:28303251

  2. Comparison of electromyography and force as interfaces for prosthetic control.

    PubMed

    Corbett, Elaine A; Perreault, Eric J; Kuiken, Todd A

    2011-01-01

    The ease with which persons with upper-limb amputations can control their powered prostheses is largely determined by the efficacy of the user command interface. One needs to understand the abilities of the human operator regarding the different available options. Electromyography (EMG) is widely used to control powered upper-limb prostheses. It is an indirect estimator of muscle force and may be expected to limit the control capabilities of the prosthesis user. This study compared EMG control with force control, an interface that is used in everyday interactions with the environment. We used both methods to perform a position-tracking task. Direct-position control of the wrist provided an upper bound for human-operator capabilities. The results demonstrated that an EMG control interface is as effective as force control for the position-tracking task. We also examined the effects of gain and tracking frequency on EMG control to explore the limits of this control interface. We found that information transmission rates for myoelectric control were best at higher tracking frequencies than at the frequencies previously reported for position control. The results may be useful for the design of prostheses and prosthetic controllers.

  3. EMG synchrony to assess impaired corticomotor control of locomotion after stroke.

    PubMed

    Lodha, Neha; Chen, Yen-Ting; McGuirk, Theresa E; Fox, Emily J; Kautz, Steven A; Christou, Evangelos A; Clark, David J

    2017-12-01

    Adapting one's gait pattern requires a contribution from cortical motor commands. Evidence suggests that frequency-based analysis of electromyography (EMG) can be used to detect this cortical contribution. Specifically, increased EMG synchrony between synergistic muscles in the Piper frequency band has been linked to heightened corticomotor contribution to EMG. Stroke-related damage to cerebral motor pathways would be expected to diminish EMG Piper synchrony. The objective of this study is therefore to test the hypothesis that EMG Piper synchrony is diminished in the paretic leg relative to nonparetic and control legs, particularly during a long-step task of walking adaptability. Twenty adults with post-stroke hemiparesis and seventeen healthy controls participated in this study. EMG Piper synchrony increased more for the control legs compare to the paretic legs when taking a non-paretic long step (5.02±3.22% versus 0.86±2.62%), p<0.01) and when taking a paretic long step (2.04±1.98% versus 0.70±2.34%, p<0.05). A similar but non-significant trend was evident when comparing non-paretic and paretic legs. No statistically significant differences in EMG Piper synchrony were found between legs for typical walking. EMG Piper synchrony was positively associated with walking speed and step length within the stroke group. These findings support the assertion that EMG Piper synchrony indicates corticomotor contribution to walking. Published by Elsevier Ltd.

  4. Use of Non-invasive Uterine Electromyography in the Diagnosis of Preterm Labour

    PubMed Central

    Lucovnik, M.; Novak-Antolic, Z.; Garfield, R.E.

    2012-01-01

    Predictive values of methods currently used in the clinics to diagnose preterm labour are low. This leads to missed opportunities to improve neonatal outcomes and, on the other hand, to unnecessary hospitalizations and treatments. In addition, research of new and potentially more effective preterm labour treatments is hindered by the inability to include only patients in true preterm labour into studies. Uterine electromyography (EMG) detects changes in cell excitability and coupling required for labour and has higher predictive values for preterm delivery than currently available methods. This methodology could also provide a better means to evaluate various therapeutic interventions for preterm labour. Our manuscript presents a review of uterine EMG studies examining the potential clinical value that this technology possesses over what is available to physicians currently. We also evaluated the impact that uterine EMG could have on investigation of preterm labour treatments by calculating sample sizes for studies using EMG vs. current methods to enrol women. Besides helping clinicians to make safer and more cost-effective decisions when managing patients with preterm contractions, implementation of uterine EMG for diagnosis of preterm labour would also greatly reduce sample sizes required for studies of treatments. PMID:24753891

  5. Expiratory Muscle Strength Training Evaluated With Simultaneous High Resolution Manometry and Electromyography

    PubMed Central

    Hutcheson, Katherine A.; Hammer, Michael J.; Rosen, Sarah P.; Jones, Corinne A.; McCulloch, Timothy M.

    2017-01-01

    Objective To examine feasibility of a simultaneous high-resolution pharyngeal manometry (HRM) and electromyography (EMG) experimental paradigm to detect swallowing-related patterns of palatal, laryngeal, and pharyngeal muscle activity during expiratory training. Study Design Technical report. Methods Simultaneous HRM, surface submental, and intramuscular EMG were acquired in two healthy participants during five tasks: 10-cc water swallow, maximum expiratory pressure (MEP) testing, and expiratory muscle strength training (EMST) at three pressure levels (sham, 50%, and 75% MEP). Results Experimental conditions were feasible. Velopharyngeal closing pressure, palate EMG activity, and pharyngeal EMG activity increased as expiratory load increased. In contrast, thyroarytenoid EMG activity was low during the expiratory task, consistent with glottic opening during exhalation. Submental EMG patterns were more variable during expiratory tasks. Intraluminal air pressures recorded with HRM were correlated with measured expiratory pressures and target valve-opening pressures of the EMST device. Conclusion Results suggest that a simultaneous HRM/EMG/EMST paradigm may be used to detect previously unquantified swallowing-related muscle activity during EMST, particularly in the palate and pharynx. Our approach and initial findings will be helpful to guide future hypothesis-driven studies and may enable investigators to evaluate other muscle groups active during these tasks. Defining mechanisms of action is a critical next step toward refining therapeutic algorithms using EMST and other targeted treatments for populations with dysphagia and airway disorders. PMID:28083946

  6. Electroencephalogram–Electromyography Coupling Analysis in Stroke Based on Symbolic Transfer Entropy

    PubMed Central

    Gao, Yunyuan; Ren, Leilei; Li, Rihui; Zhang, Yingchun

    2018-01-01

    The coupling strength between electroencephalogram (EEG) and electromyography (EMG) signals during motion control reflects the interaction between the cerebral motor cortex and muscles. Therefore, neuromuscular coupling characterization is instructive in assessing motor function. In this study, to overcome the limitation of losing the characteristics of signals in conventional time series symbolization methods, a variable scale symbolic transfer entropy (VS-STE) analysis approach was proposed for corticomuscular coupling evaluation. Post-stroke patients (n = 5) and healthy volunteers (n = 7) were recruited and participated in various tasks (left and right hand gripping, elbow bending). The proposed VS-STE was employed to evaluate the corticomuscular coupling strength between the EEG signal measured from the motor cortex and EMG signal measured from the upper limb in both the time-domain and frequency-domain. Results showed a greater strength of the bi-directional (EEG-to-EMG and EMG-to-EEG) VS-STE in post-stroke patients compared to healthy controls. In addition, the strongest EEG–EMG coupling strength was observed in the beta frequency band (15–35 Hz) during the upper limb movement. The predefined coupling strength of EMG-to-EEG in the affected side of the patient was larger than that of EEG-to-EMG. In conclusion, the results suggested that the corticomuscular coupling is bi-directional, and the proposed VS-STE can be used to quantitatively characterize the non-linear synchronization characteristics and information interaction between the primary motor cortex and muscles. PMID:29354091

  7. Development of new muscle contraction sensor to replace sEMG for using in muscles analysis fields.

    PubMed

    Zhang, D; Matsuoka, Y; Kong, W; Imtiaz, U; Bartolomeo, L; Cosentino, S; Zecca, M; Sessa, S; Ishii, H; Takanishi, A

    2014-01-01

    Nowadays, the technologies for detecting, processing and interpreting bioelectrical signals have improved tremendously. In particular, surface electromyography (sEMG) has gained momentum in a wide range of applications in various fields. However, sEMG sensing has several shortcomings, the most important being: measurements are heavily sensible to individual differences, sensors are difficult to position and very expensive. In this paper, the authors will present an innovative muscle contraction sensing device (MC sensor), aiming to replace sEMG sensing in the field of muscle movement analysis. Compared with sEMG, this sensor is easier to position, setup and use, less dependent from individual differences, and less expensive. Preliminary experiments, described in this paper, confirm that MC sensing is suitable for muscle contraction analysis, and compare the results of sEMG and MC sensor for the measurement of forearm muscle contraction.

  8. Cortical effect and functional recovery by the electromyography-triggered neuromuscular stimulation in chronic stroke patients.

    PubMed

    Shin, Hwa Kyung; Cho, Sang Hyun; Jeon, Hye-seon; Lee, Young-Hee; Song, Jun Chan; Jang, Sung Ho; Lee, Chu-Hee; Kwon, Yong Hyun

    2008-09-19

    We investigated the effect of electromyography (EMG)-triggered neuromuscular electrical stimulation (NMES; EMG-stim) on functional recovery of the hemiparetic hand and the related cortical activation pattern in chronic stroke patients. We enrolled 14 stroke patients, who were randomly assigned to the EMG-stim (n=7) or the control groups (n=7). The EMG-stim was applied to the wrist extensor of the EMG-stim group for two sessions (30 min/session) a day, five times per week for 10 weeks. Four functional tests (box and block, strength, the accuracy index, and the on/offset time of muscle contraction) and functional MRI (fMRI) were performed before and after treatment. fMRI was measured at 1.5 T in parallel with timed finger flexion-extension movements at a fixed rate. Following treatment, the EMG-stim group showed a significant improvement in all functional tests. The main cortical activation change with such functional improvement was shifted from the ipsilateral sensorimotor cortex (SMC) to the contralateral SMC. We demonstrated that 10-week EMG-stim can induce functional recovery and change of cortical activation pattern in the hemiparetic hand of chronic stroke patients.

  9. Motor unit number estimation and quantitative needle electromyography in stroke patients.

    PubMed

    Kouzi, Ioanna; Trachani, Eftichia; Anagnostou, Evangelos; Rapidi, Christina-Anastasia; Ellul, John; Sakellaropoulos, George C; Chroni, Elisabeth

    2014-12-01

    To evaluate the effect of upper motor neuron damage upon motor units' function by means of two separate and supplementary electrophysiological methods. The abductor digiti minimi muscle of the non-paretic and the paretic side was studied in forty-six stroke patients with (a) motor unit number estimation (MUNE) - adapted multiple point stimulation method and (b) computerized quantitative needle electromyography (EMG) assessing the configuration of voluntary recruited motor unit potentials. Main outcome comparisons were focused on differences between non-paretic and paretic side. On the affected hands mean MUNE value was significantly lower and mean area of the surface recorded single motor unit potentials was significantly larger than the corresponding ones on the non-paretic hands. EMG findings did not reveal remarkable differences between the two sides. Neither severity nor chronicity of stroke was related to MUNE or EMG parameters. MUNE results, which suggested reduced motor unit numbers in stroke patients, in conjunction with the normal EMG features in these same muscles has given rise to different interpretations. In a clinical setting, reinnervation type changes in the EMG similar to that occurring in neuronopathies or axonal neuropathies should not be expected in muscles with central neurogenic lesion. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. Effects of inspiratory muscle training on respiratory muscle electromyography and dyspnea during exercise in healthy men.

    PubMed

    Ramsook, Andrew H; Molgat-Seon, Yannick; Schaeffer, Michele R; Wilkie, Sabrina S; Camp, Pat G; Reid, W Darlene; Romer, Lee M; Guenette, Jordan A

    2017-05-01

    Inspiratory muscle training (IMT) has consistently been shown to reduce exertional dyspnea in health and disease; however, the physiological mechanisms remain poorly understood. A growing body of literature suggests that dyspnea intensity can be explained largely by an awareness of increased neural respiratory drive, as measured indirectly using diaphragmatic electromyography (EMGdi). Accordingly, we sought to determine whether improvements in dyspnea following IMT can be explained by decreases in inspiratory muscle electromyography (EMG) activity. Twenty-five young, healthy, recreationally active men completed a detailed familiarization visit followed by two maximal incremental cycle exercise tests separated by 5 wk of randomly assigned pressure threshold IMT or sham control (SC) training. The IMT group ( n = 12) performed 30 inspiratory efforts twice daily against a 30-repetition maximum intensity. The SC group ( n = 13) performed a daily bout of 60 inspiratory efforts against 10% maximal inspiratory pressure (MIP), with no weekly adjustments. Dyspnea intensity was measured throughout exercise using the modified 0-10 Borg scale. Sternocleidomastoid and scalene EMG was measured using surface electrodes, whereas EMGdi was measured using a multipair esophageal electrode catheter. IMT significantly improved MIP (pre: -138 ± 45 vs. post: -160 ± 43 cmH 2 O, P < 0.01), whereas the SC intervention did not. Dyspnea was significantly reduced at the highest equivalent work rate (pre: 7.6 ± 2.5 vs. post: 6.8 ± 2.9 Borg units, P < 0.05), but not in the SC group, with no between-group interaction effects. There were no significant differences in respiratory muscle EMG during exercise in either group. Improvements in dyspnea intensity ratings following IMT in healthy humans cannot be explained by changes in the electrical activity of the inspiratory muscles. NEW & NOTEWORTHY Exertional dyspnea intensity is thought to reflect an increased awareness of neural respiratory

  11. Effects of inspiratory muscle training on respiratory muscle electromyography and dyspnea during exercise in healthy men

    PubMed Central

    Molgat-Seon, Yannick; Schaeffer, Michele R.; Wilkie, Sabrina S.; Camp, Pat G.; Reid, W. Darlene; Romer, Lee M.

    2017-01-01

    Inspiratory muscle training (IMT) has consistently been shown to reduce exertional dyspnea in health and disease; however, the physiological mechanisms remain poorly understood. A growing body of literature suggests that dyspnea intensity can be explained largely by an awareness of increased neural respiratory drive, as measured indirectly using diaphragmatic electromyography (EMGdi). Accordingly, we sought to determine whether improvements in dyspnea following IMT can be explained by decreases in inspiratory muscle electromyography (EMG) activity. Twenty-five young, healthy, recreationally active men completed a detailed familiarization visit followed by two maximal incremental cycle exercise tests separated by 5 wk of randomly assigned pressure threshold IMT or sham control (SC) training. The IMT group (n = 12) performed 30 inspiratory efforts twice daily against a 30-repetition maximum intensity. The SC group (n = 13) performed a daily bout of 60 inspiratory efforts against 10% maximal inspiratory pressure (MIP), with no weekly adjustments. Dyspnea intensity was measured throughout exercise using the modified 0–10 Borg scale. Sternocleidomastoid and scalene EMG was measured using surface electrodes, whereas EMGdi was measured using a multipair esophageal electrode catheter. IMT significantly improved MIP (pre: −138 ± 45 vs. post: −160 ± 43 cmH2O, P < 0.01), whereas the SC intervention did not. Dyspnea was significantly reduced at the highest equivalent work rate (pre: 7.6 ± 2.5 vs. post: 6.8 ± 2.9 Borg units, P < 0.05), but not in the SC group, with no between-group interaction effects. There were no significant differences in respiratory muscle EMG during exercise in either group. Improvements in dyspnea intensity ratings following IMT in healthy humans cannot be explained by changes in the electrical activity of the inspiratory muscles. NEW & NOTEWORTHY Exertional dyspnea intensity is thought to reflect an increased awareness of neural respiratory

  12. Artificial neural network EMG classifier for functional hand grasp movements prediction.

    PubMed

    Gandolla, Marta; Ferrante, Simona; Ferrigno, Giancarlo; Baldassini, Davide; Molteni, Franco; Guanziroli, Eleonora; Cotti Cottini, Michele; Seneci, Carlo; Pedrocchi, Alessandra

    2017-12-01

    Objective To design and implement an electromyography (EMG)-based controller for a hand robotic assistive device, which is able to classify the user's motion intention before the effective kinematic movement execution. Methods Multiple degrees-of-freedom hand grasp movements (i.e. pinching, grasp an object, grasping) were predicted by means of surface EMG signals, recorded from 10 bipolar EMG electrodes arranged in a circular configuration around the forearm 2-3 cm from the elbow. Two cascaded artificial neural networks were then exploited to detect the patient's motion intention from the EMG signal window starting from the electrical activity onset to movement onset (i.e. electromechanical delay). Results The proposed approach was tested on eight healthy control subjects (4 females; age range 25-26 years) and it demonstrated a mean ± SD testing performance of 76% ± 14% for correctly predicting healthy users' motion intention. Two post-stroke patients tested the controller and obtained 79% and 100% of correctly classified movements under testing conditions. Conclusion A task-selection controller was developed to estimate the intended movement from the EMG measured during the electromechanical delay.

  13. Artificial neural network EMG classifier for functional hand grasp movements prediction

    PubMed Central

    Ferrante, Simona; Ferrigno, Giancarlo; Baldassini, Davide; Molteni, Franco; Guanziroli, Eleonora; Cotti Cottini, Michele; Seneci, Carlo; Pedrocchi, Alessandra

    2016-01-01

    Objective To design and implement an electromyography (EMG)-based controller for a hand robotic assistive device, which is able to classify the user's motion intention before the effective kinematic movement execution. Methods Multiple degrees-of-freedom hand grasp movements (i.e. pinching, grasp an object, grasping) were predicted by means of surface EMG signals, recorded from 10 bipolar EMG electrodes arranged in a circular configuration around the forearm 2–3 cm from the elbow. Two cascaded artificial neural networks were then exploited to detect the patient's motion intention from the EMG signal window starting from the electrical activity onset to movement onset (i.e. electromechanical delay). Results The proposed approach was tested on eight healthy control subjects (4 females; age range 25–26 years) and it demonstrated a mean ± SD testing performance of 76% ± 14% for correctly predicting healthy users' motion intention. Two post-stroke patients tested the controller and obtained 79% and 100% of correctly classified movements under testing conditions. Conclusion A task-selection controller was developed to estimate the intended movement from the EMG measured during the electromechanical delay. PMID:27677300

  14. Long-term surface EMG monitoring using K-means clustering and compressive sensing

    NASA Astrophysics Data System (ADS)

    Balouchestani, Mohammadreza; Krishnan, Sridhar

    2015-05-01

    In this work, we present an advanced K-means clustering algorithm based on Compressed Sensing theory (CS) in combination with the K-Singular Value Decomposition (K-SVD) method for Clustering of long-term recording of surface Electromyography (sEMG) signals. The long-term monitoring of sEMG signals aims at recording of the electrical activity produced by muscles which are very useful procedure for treatment and diagnostic purposes as well as for detection of various pathologies. The proposed algorithm is examined for three scenarios of sEMG signals including healthy person (sEMG-Healthy), a patient with myopathy (sEMG-Myopathy), and a patient with neuropathy (sEMG-Neuropathr), respectively. The proposed algorithm can easily scan large sEMG datasets of long-term sEMG recording. We test the proposed algorithm with Principal Component Analysis (PCA) and Linear Correlation Coefficient (LCC) dimensionality reduction methods. Then, the output of the proposed algorithm is fed to K-Nearest Neighbours (K-NN) and Probabilistic Neural Network (PNN) classifiers in order to calclute the clustering performance. The proposed algorithm achieves a classification accuracy of 99.22%. This ability allows reducing 17% of Average Classification Error (ACE), 9% of Training Error (TE), and 18% of Root Mean Square Error (RMSE). The proposed algorithm also reduces 14% clustering energy consumption compared to the existing K-Means clustering algorithm.

  15. Assessment of Dry Epidermal Electrodes for Long-Term Electromyography Measurements

    PubMed Central

    Peters, Keshia M.; Milovanovic, Ivana; Kuang, Irene; Yang, Zeyu; Lu, Nanshu; Steele, Katherine M.

    2018-01-01

    Commercially available electrodes can only provide quality surface electromyography (sEMG) measurements for a limited duration due to user discomfort and signal degradation, but in many applications, collecting sEMG data for a full day or longer is desirable to enhance clinical care. Few studies for long-term sEMG have assessed signal quality of electrodes using clinically relevant tests. The goal of this research was to evaluate flexible, gold-based epidermal sensor system (ESS) electrodes for long-term sEMG recordings. We collected sEMG and impedance data from eight subjects from ESS and standard clinical electrodes on upper extremity muscles during maximum voluntary isometric contraction tests, dynamic range of motion tests, the Jebsen Taylor Hand Function Test, and the Box & Block Test. Four additional subjects were recruited to test the stability of ESS signals over four days. Signals from the ESS and traditional electrodes were strongly correlated across tasks. Measures of signal quality, such as signal-to-noise ratio and signal-to-motion ratio, were also similar for both electrodes. Over the four-day trial, no significant decrease in signal quality was observed in the ESS electrodes, suggesting that thin, flexible electrodes may provide a robust tool that does not inhibit movement or irritate the skin for long-term measurements of muscle activity in rehabilitation and other applications. PMID:29677129

  16. Pathogenesis of cranial neuropathies in Moebius syndrome: Electrodiagnostic orofacial studies.

    PubMed

    Renault, Francis; Flores-Guevara, Roberto; Sergent, Bernard; Baudon, Jean Jacques; Aouizerate, Jessie; Vazquez, Marie-Paule; Gitiaux, Cyril

    2018-02-09

    We designed a retrospective study of 59 patients with congenital sporadic nonprogressive bilateral facial and abducens palsies. Examinations included needle electromyography (EMG) of facial and oral muscles, facial nerve motor latency and conduction velocity (FNCV), and blink responses (BR). Neurogenic EMG changes were found in 1 or more muscles in 55 of 59 patients, with no abnormal spontaneous activity. EMG changes were homogeneously neurogenic in 17 patients, homogeneously myopathic in 1 patient, and heterogeneous in 41 of 59 patients. Motor latency was increased according to recordings from 52 of 137 facial muscles. An increase of motor latency was not associated with neurogenic EMG (Fischer's test: right, P = 1; left, P = 0.76). FNCV was slowed in 19 of 36 patients. BR was absent bilaterally in 35 of 58 patients; when present, R1 and R2 latencies were normal. Our results support the hypothesis of an early developmental defect localized in motor cranial nerves with spared V-VII internuclear pathways. Muscle Nerve, 2018. © 2018 Wiley Periodicals, Inc.

  17. Sound-induced facial synkinesis following facial nerve paralysis.

    PubMed

    Ma, Ming-San; van der Hoeven, Johannes H; Nicolai, Jean-Philippe A; Meek, Marcel F

    2009-08-01

    Facial synkinesis (or synkinesia) (FS) occurs frequently after paresis or paralysis of the facial nerve and is in most cases due to aberrant regeneration of (branches of) the facial nerve. Patients suffer from inappropriate and involuntary synchronous facial muscle contractions. Here we describe two cases of sound-induced facial synkinesis (SFS) after facial nerve injury. As far as we know, this phenomenon has not been described in the English literature before. Patient A presented with right hemifacial palsy after lesion of the facial nerve due to skull base fracture. He reported involuntary muscle activity at the right corner of the mouth, specifically on hearing ringing keys. Patient B suffered from left hemifacial palsy following otitis media and developed involuntary muscle contraction in the facial musculature specifically on hearing clapping hands or a trumpet sound. Both patients were evaluated by means of video, audio and EMG analysis. Possible mechanisms in the pathophysiology of SFS are postulated and therapeutic options are discussed.

  18. Iterative Assessment of Statistically-Oriented and Standard Algorithms for Determining Muscle Onset with Intramuscular Electromyography.

    PubMed

    Tenan, Matthew S; Tweedell, Andrew J; Haynes, Courtney A

    2017-12-01

    The onset of muscle activity, as measured by electromyography (EMG), is a commonly applied metric in biomechanics. Intramuscular EMG is often used to examine deep musculature and there are currently no studies examining the effectiveness of algorithms for intramuscular EMG onset. The present study examines standard surface EMG onset algorithms (linear envelope, Teager-Kaiser Energy Operator, and sample entropy) and novel algorithms (time series mean-variance analysis, sequential/batch processing with parametric and nonparametric methods, and Bayesian changepoint analysis). Thirteen male and 5 female subjects had intramuscular EMG collected during isolated biceps brachii and vastus lateralis contractions, resulting in 103 trials. EMG onset was visually determined twice by 3 blinded reviewers. Since the reliability of visual onset was high (ICC (1,1) : 0.92), the mean of the 6 visual assessments was contrasted with the algorithmic approaches. Poorly performing algorithms were stepwise eliminated via (1) root mean square error analysis, (2) algorithm failure to identify onset/premature onset, (3) linear regression analysis, and (4) Bland-Altman plots. The top performing algorithms were all based on Bayesian changepoint analysis of rectified EMG and were statistically indistinguishable from visual analysis. Bayesian changepoint analysis has the potential to produce more reliable, accurate, and objective intramuscular EMG onset results than standard methodologies.

  19. New method of neck surface electromyography for the evaluation of tongue-lifting activity.

    PubMed

    Manda, Y; Maeda, N; Pan, Q; Sugimoto, K; Hashimoto, Y; Tanaka, Y; Kodama, N; Minagi, S

    2016-06-01

    Elevation of the posterior part of the tongue is important for normal deglutition and speech. The purpose of this study was to develop a new surface electromyography (EMG) method to non-invasively and objectively evaluate activity in the muscles that control lifting movement in the posterior tongue. Neck surface EMG (N-EMG) was recorded using differential surface electrodes placed on the neck, 1 cm posterior to the posterior border of the mylohyoid muscle on a line orthogonal to the lower border of the mandible. Experiment 1: Three healthy volunteers (three men, mean age 37·7 years) participated in an evaluation of detection method of the posterior tongue lifting up movement. EMG recordings from the masseter, temporalis and submental muscles and N-EMG revealed that i) N-EMG was not affected by masseter muscle EMG and ii) N-EMG activity was not observed during simple jaw opening and tongue protrusion, revealing the functional difference between submental surface EMG and N-EMG. Experiment 2: Seven healthy volunteers (six men and one woman, mean age 27·9 years) participated in a quantitative evaluation of muscle activity. Tongue-lifting tasks were perfor-med, exerting a prescribed force of 20, 50, 100 and 150 gf with visual feedback. For all subjects, a significant linear relationship was observed bet-ween the tongue-lifting force and N-EMG activity (P < 0·01). These findings indicate that N-EMG can be used to quantify the force of posterior tongue lifting and could be useful to evaluate the effect of tongue rehabilitation in future studies. © 2016 John Wiley & Sons Ltd.

  20. The Relationship between Submental Surface Electromyography and Hyo-Laryngeal Kinematic Measures of Mendelsohn Maneuver Duration

    ERIC Educational Resources Information Center

    Azola, Alba M.; Greene, Lindsey R.; Taylor-Kamara, Isha; Macrae, Phoebe; Anderson, Cheryl; Humbert, Ianessa A.

    2015-01-01

    Purpose: The Mendelsohn Maneuver (MM) is a commonly prescribed technique that is taught to individuals with dysphagia to improve swallowing ability. Due to cost and safety concerns associated with videofluoroscopy (VFS) use, submental surface electromyography (ssEMG) is commonly used in place of VFS to train the MM in clinical and research…

  1. A method for discrimination of noise and EMG signal regions recorded during rhythmic behaviors.

    PubMed

    Ying, Rex; Wall, Christine E

    2016-12-08

    Analyses of muscular activity during rhythmic behaviors provide critical data for biomechanical studies. Electrical potentials measured from muscles using electromyography (EMG) require discrimination of noise regions as the first step in analysis. An experienced analyst can accurately identify the onset and offset of EMG but this process takes hours to analyze a short (10-15s) record of rhythmic EMG bursts. Existing computational techniques reduce this time but have limitations. These include a universal threshold for delimiting noise regions (i.e., a single signal value for identifying the EMG signal onset and offset), pre-processing using wide time intervals that dampen sensitivity for EMG signal characteristics, poor performance when a low frequency component (e.g., DC offset) is present, and high computational complexity leading to lack of time efficiency. We present a new statistical method and MATLAB script (EMG-Extractor) that includes an adaptive algorithm to discriminate noise regions from EMG that avoids these limitations and allows for multi-channel datasets to be processed. We evaluate the EMG-Extractor with EMG data on mammalian jaw-adductor muscles during mastication, a rhythmic behavior typified by low amplitude onsets/offsets and complex signal pattern. The EMG-Extractor consistently and accurately distinguishes noise from EMG in a manner similar to that of an experienced analyst. It outputs the raw EMG signal region in a form ready for further analysis. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Simulation of facial expressions using person-specific sEMG signals controlling a biomechanical face model.

    PubMed

    Eskes, Merijn; Balm, Alfons J M; van Alphen, Maarten J A; Smeele, Ludi E; Stavness, Ian; van der Heijden, Ferdinand

    2018-01-01

    Functional inoperability in advanced oral cancer is difficult to assess preoperatively. To assess functions of lips and tongue, biomechanical models are required. Apart from adjusting generic models to individual anatomy, muscle activation patterns (MAPs) driving patient-specific functional movements are necessary to predict remaining functional outcome. We aim to evaluate how volunteer-specific MAPs derived from surface electromyographic (sEMG) signals control a biomechanical face model. Muscle activity of seven facial muscles in six volunteers was measured bilaterally with sEMG. A triple camera set-up recorded 3D lip movement. The generic face model in ArtiSynth was adapted to our needs. We controlled the model using the volunteer-specific MAPs. Three activation strategies were tested: activating all muscles [Formula: see text], selecting the three muscles showing highest muscle activity bilaterally [Formula: see text]-this was calculated by taking the mean of left and right muscles and then selecting the three with highest variance-and activating the muscles considered most relevant per instruction [Formula: see text], bilaterally. The model's lip movement was compared to the actual lip movement performed by the volunteers, using 3D correlation coefficients [Formula: see text]. The correlation coefficient between simulations and measurements with [Formula: see text] resulted in a median [Formula: see text] of 0.77. [Formula: see text] had a median [Formula: see text] of 0.78, whereas with [Formula: see text] the median [Formula: see text] decreased to 0.45. We demonstrated that MAPs derived from noninvasive sEMG measurements can control movement of the lips in a generic finite element face model with a median [Formula: see text] of 0.78. Ultimately, this is important to show the patient-specific residual movement using the patient's own MAPs. When the required treatment tools and personalisation techniques for geometry and anatomy become available, this may

  3. Preliminary investigation of an electromyography-controlled video game as a home program for persons in the chronic phase of stroke recovery.

    PubMed

    Donoso Brown, Elena V; McCoy, Sarah Westcott; Fechko, Amber S; Price, Robert; Gilbertson, Torey; Moritz, Chet T

    2014-08-01

    To investigate the preliminary effectiveness of surface electromyography (sEMG) biofeedback delivered via interaction with a commercial computer game to improve motor control in chronic stroke survivors. Single-blinded, 1-group, repeated-measures design: A1, A2, B, A3 (A, assessment; B, intervention). Laboratory and participants' homes. A convenience sample of persons (N=9) between 40 and 75 years of age with moderate to severe upper extremity motor impairment and at least 6 months poststroke completed the study. The electromyography-controlled video game system targeted the wrist muscle activation with the goal of increasing selective muscle activation. Participants received several laboratory training sessions with the system and then were instructed to use the system at home for 45 minutes, 5 times per week for the following 4 weeks. Primary outcome measures included duration of system use, sEMG during home play, and pre/post sEMG measures during active wrist motion. Secondary outcomes included kinematic analysis of movement and functional outcomes, including the Wolf Motor Function Test and the Chedoke Arm and Hand Activity Inventory-9. One third of participants completed or exceeded the recommended amount of system use. Statistically significant changes were observed on both game play and pre/post sEMG outcomes. Limited carryover, however, was observed on kinematic or functional outcomes. This preliminary investigation indicates that use of the electromyography-controlled video game impacts muscle activation. Limited changes in kinematic and activity level outcomes, however, suggest that the intervention may benefit from the inclusion of a functional activity component. Copyright © 2014 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  4. Expiratory muscle strength training evaluated with simultaneous high-resolution manometry and electromyography.

    PubMed

    Hutcheson, Katherine A; Hammer, Michael J; Rosen, Sarah P; Jones, Corinne A; McCulloch, Timothy M

    2017-04-01

    To examine feasibility of a simultaneous high-resolution pharyngeal manometry (HRM) and electromyography (EMG) experimental paradigm to detect swallowing-related patterns of palatal, laryngeal, and pharyngeal muscle activity during expiratory training. Technical report. Simultaneous HRM, surface submental, and intramuscular EMG were acquired in two healthy participants during five tasks: 10-cc water swallow, maximum expiratory pressure (MEP) testing, and expiratory muscle strength training (EMST) at three pressure levels (sham, 50%, and 75% MEP). Experimental conditions were feasible. Velopharyngeal closing pressure, palate EMG activity, and pharyngeal EMG activity increased as expiratory load increased. In contrast, thyroarytenoid EMG activity was low during the expiratory task, consistent with glottic opening during exhalation. Submental EMG patterns were more variable during expiratory tasks. Intraluminal air pressures recorded with HRM were correlated with measured expiratory pressures and target valve-opening pressures of the EMST device. Results suggest that a simultaneous HRM/EMG/EMST paradigm may be used to detect previously unquantified swallowing-related muscle activity during EMST, particularly in the palate and pharynx. Our approach and initial findings will be helpful to guide future hypothesis-driven studies and may enable investigators to evaluate other muscle groups active during these tasks. Defining mechanisms of action is a critical next step toward refining therapeutic algorithms using EMST and other targeted treatments for populations with dysphagia and airway disorders. 4. Laryngoscope, 127:797-804, 2017. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  5. Effect of obesity on preterm delivery prediction by transabdominal recording of uterine electromyography.

    PubMed

    Lucovnik, Miha; Chambliss, Linda R; Blumrick, Richard; Balducci, James; Gersak, Ksenija; Garfield, Robert E

    2016-10-01

    It has been shown that noninvasive uterine electromyography (EMG) can identify true preterm labor more accurately than methods available to clinicians today. The objective of this study was to evaluate the effect of body mass index (BMI) on the accuracy of uterine EMG in predicting preterm delivery. Predictive values of uterine EMG for preterm delivery were compared in obese versus overweight/normal BMI patients. Hanley-McNeil test was used to compare receiver operator characteristics curves in these groups. Previously reported EMG cutoffs were used to determine groups with false positive/false negative and true positive/true negative EMG results. BMI in these groups was compared with Student t test (p < 0.05 significant). A total of 88 patients were included: 20 obese, 64 overweight, and four with normal BMI. EMG predicted preterm delivery within 7 days with area under the curve = 0.95 in the normal/overweight group, and with area under the curve = 1.00 in the obese group (p = 0.08). Six patients in true preterm labor (delivering within 7 days from EMG measurement) had low EMG values (false negative group). There were no false positive results. No significant differences in patient's BMI were noted between false negative group patients and preterm labor patients with high EMG values (true positive group) and nonlabor patients with low EMG values (true negative group; p = 0.32). Accuracy of noninvasive uterine EMG monitoring and its predictive value for preterm delivery are not affected by obesity. Copyright © 2016. Published by Elsevier B.V.

  6. Spatial variability in cortex-muscle coherence investigated with magnetoencephalography and high-density surface electromyography

    PubMed Central

    Botter, Alberto; Bourguignon, Mathieu; Jousmäki, Veikko; Hari, Riitta

    2015-01-01

    Cortex-muscle coherence (CMC) reflects coupling between magnetoencephalography (MEG) and surface electromyography (sEMG), being strongest during isometric contraction but absent, for unknown reasons, in some individuals. We used a novel nonmagnetic high-density sEMG (HD-sEMG) electrode grid (36 mm × 12 mm; 60 electrodes separated by 3 mm) to study effects of sEMG recording site, electrode derivation, and rectification on the strength of CMC. Monopolar sEMG from right thenar and 306-channel whole-scalp MEG were recorded from 14 subjects during 4-min isometric thumb abduction. CMC was computed for 60 monopolar, 55 bipolar, and 32 Laplacian HD-sEMG derivations, and two derivations were computed to mimic “macroscopic” monopolar and bipolar sEMG (electrode diameter 9 mm; interelectrode distance 21 mm). With unrectified sEMG, 12 subjects showed statistically significant CMC in 91–95% of the HD-sEMG channels, with maximum coherence at ∼25 Hz. CMC was about a fifth stronger for monopolar than bipolar and Laplacian derivations. Monopolar derivations resulted in most uniform CMC distributions across the thenar and in tightest cortical source clusters in the left rolandic hand area. CMC was 19–27% stronger for HD-sEMG than for “macroscopic” monopolar or bipolar derivations. EMG rectification reduced the CMC peak by a quarter, resulted in a more uniformly distributed CMC across the thenar, and provided more tightly clustered cortical sources than unrectifed sEMGs. Moreover, it revealed CMC at ∼12 Hz. We conclude that HD-sEMG, especially with monopolar derivation, can facilitate detection of CMC and that individual muscle anatomy cannot explain the high interindividual CMC variability. PMID:26354317

  7. Novel use of combination of electromyography and ultrasound to guide quadratus lumborum block after open appendicectomy.

    PubMed

    Mullins, Cormac F; O'Brien, Conor; O'Connor, Therese C

    2017-05-15

    The quadratus lumborum (QL) block facilitates the administration of anaesthesia to the anterior abdominal wall. The use of ultrasound (US) improves the accuracy of the QL block and reduces the risk of adverse events. Electromyography (EMG) in combination with US for muscle plane blocks has not been described previously. We postulated that the addition of EMG-guided needle positioning might assist the execution of this block. This case report describes the first use of combined needle EMG and US to carry out a QL block performed for postoperative analgesia following an open appendicectomy. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  8. Knee joint angle affects EMG-force relationship in the vastus intermedius muscle.

    PubMed

    Saito, Akira; Akima, Hiroshi

    2013-12-01

    It is not understood how the knee joint angle affects the relationship between electromyography (EMG) and force of four individual quadriceps femoris (QF) muscles. The purpose of this study was to examine the effect of the knee joint angle on the EMG-force relationship of the four individual QF muscles, particularly the vastus intermedius (VI), during isometric knee extensions. Eleven healthy men performed 20-100% of maximal voluntary contraction (MVC) at knee joint angles of 90°, 120° and 150°. Surface EMG of the four QF synergists was recorded and normalized by the root mean square during MVC. The normalized EMG of the four QF synergists at a knee joint angle of 150° was significantly lower than that at 90° and 120° (P < 0.05). Comparing the normalized EMG among the four QF synergists, a significantly lower normalized EMG was observed in the VI at 150° as compared with the other three QF muscles (P < 0.05). These results suggest that the EMG-force relationship of the four QF synergists shifted downward at an extended knee joint angle of 150°. Furthermore, the neuromuscular activation of the VI was the most sensitive to change in muscle length among the four QF synergistic muscles. Copyright © 2013 Elsevier Ltd. All rights reserved.

  9. Associations between apparent diffusion coefficient and electromyography parameters in myositis-A preliminary study.

    PubMed

    Meyer, Hans-Jonas; Emmer, Alexander; Kornhuber, Malte; Surov, Alexey

    2018-05-01

    MRI is widely used in several muscle disorders. Diffusion-weighted imaging (DWI) is an emergent imaging modality sensitive to microstructural alterations in tissue. The apparent diffusion coefficient (ADC) is used to quantify the random motion of water molecules. Electromyography (EMG) is a clinically used diagnostic tool in myositis. The aim of this study was to elucidate possible associations between ADC values and EMG findings in myositis patients. Seven patients (eight investigated muscles) with myositis (mean age 51.43 ± 19 years) were included in this study. The diagnosis was confirmed by histopathology in every case. DWI was obtained with a 1.5-T scanner using two b-values 0 and 1000 s/mm². In all patients, a needle electromyography (EMG) was performed within 3 days to the MRI. The following EMG parameters were studied: motor unit action potential (MUAP) amplitudes and durations, as well as pathological spontaneous activity. Spearman's correlation coefficient was used to analyze associations between investigated parameters. The estimated mean ADC mean value was 1.51 ± 0.29 × 10 -3  mm²/s, mean ADC min was 1.28 ± 0.27 × 10 -3  mm²/s, and mean ADC max was 1.73 ± 0.28 × 10 -3  mm²/s. Correlation analysis identified significant associations between ADC mean and duration of the MUAP (p   = .78 P = .0279) and between ADC min and duration of the MUAP (p = .85, P = .01). There were no significant differences according to pathological spontaneous activity. ADC mean and ADC min showed strong positive correlations with the duration of the MUAP in myositis patients. Both modalities might similarly reflect muscle fiber loss in myositis patients.

  10. Masticatory Muscle Sleep Background EMG Activity is Elevated in Myofascial TMD Patients

    PubMed Central

    Raphael, Karen G.; Janal, Malvin N.; Sirois, David A.; Dubrovsky, Boris; Wigren, Pia E.; Klausner, Jack J.; Krieger, Ana C.; Lavigne, Gilles J.

    2013-01-01

    Despite theoretical speculation and strong clinical belief, recent research using laboratory polysomnographic (PSG) recording has provided new evidence that frequency of sleep bruxism (SB) masseter muscle events, including grinding or clenching of the teeth during sleep, is not increased for women with chronic myofascial temporomandibular disorder (TMD). The current case-control study compares a large sample of women suffering from chronic myofascial TMD (n=124) with a demographically matched control group without TMD (n=46) on sleep background electromyography (EMG) during a laboratory PSG study. Background EMG activity was measured as EMG root mean square (RMS) from the right masseter muscle after lights out. Sleep background EMG activity was defined as EMG RMS remaining after activity attributable to SB, other orofacial activity, other oromotor activity and movement artifacts were removed. Results indicated that median background EMG during these non SB-event periods was significantly higher (p<.01) for women with myofascial TMD (median=3.31 μV and mean=4.98 μV) than for control women (median=2.83 μV and mean=3.88 μV) with median activity in 72% of cases exceeding control activity. Moreover, for TMD cases, background EMG was positively associated and SB event-related EMG was negatively associated with pain intensity ratings (0–10 numerical scale) on post sleep waking. These data provide the foundation for a new focus on small, but persistent, elevations in sleep EMG activity over the course of the night as a mechanism of pain induction or maintenance. PMID:24237356

  11. Implementation of a Surface Electromyography-Based Upper Extremity Exoskeleton Controller Using Learning from Demonstration.

    PubMed

    Siu, Ho Chit; Arenas, Ana M; Sun, Tingxiao; Stirling, Leia A

    2018-02-05

    Upper-extremity exoskeletons have demonstrated potential as augmentative, assistive, and rehabilitative devices. Typical control of upper-extremity exoskeletons have relied on switches, force/torque sensors, and surface electromyography (sEMG), but these systems are usually reactionary, and/or rely on entirely hand-tuned parameters. sEMG-based systems may be able to provide anticipatory control, since they interface directly with muscle signals, but typically require expert placement of sensors on muscle bodies. We present an implementation of an adaptive sEMG-based exoskeleton controller that learns a mapping between muscle activation and the desired system state during interaction with a user, generating a personalized sEMG feature classifier to allow for anticipatory control. This system is robust to novice placement of sEMG sensors, as well as subdermal muscle shifts. We validate this method with 18 subjects using a thumb exoskeleton to complete a book-placement task. This learning-from-demonstration system for exoskeleton control allows for very short training times, as well as the potential for improvement in intent recognition over time, and adaptation to physiological changes in the user, such as those due to fatigue.

  12. Implementation of a Surface Electromyography-Based Upper Extremity Exoskeleton Controller Using Learning from Demonstration

    PubMed Central

    Arenas, Ana M.; Sun, Tingxiao

    2018-01-01

    Upper-extremity exoskeletons have demonstrated potential as augmentative, assistive, and rehabilitative devices. Typical control of upper-extremity exoskeletons have relied on switches, force/torque sensors, and surface electromyography (sEMG), but these systems are usually reactionary, and/or rely on entirely hand-tuned parameters. sEMG-based systems may be able to provide anticipatory control, since they interface directly with muscle signals, but typically require expert placement of sensors on muscle bodies. We present an implementation of an adaptive sEMG-based exoskeleton controller that learns a mapping between muscle activation and the desired system state during interaction with a user, generating a personalized sEMG feature classifier to allow for anticipatory control. This system is robust to novice placement of sEMG sensors, as well as subdermal muscle shifts. We validate this method with 18 subjects using a thumb exoskeleton to complete a book-placement task. This learning-from-demonstration system for exoskeleton control allows for very short training times, as well as the potential for improvement in intent recognition over time, and adaptation to physiological changes in the user, such as those due to fatigue. PMID:29401754

  13. The relationship between RMS electromyography and thickness change in the skeletal muscles.

    PubMed

    Kian-Bostanabad, Sharareh; Azghani, Mahmood-Reza

    2017-05-01

    The knowledge of muscle function may affect prescribing medications and physical treatments. Recently, ultrasound and electromyography (EMG) have been used to assess the skeletal muscles activity. The relationship between these methods has been reported in numerous articles qualitatively. In this paper, the relationship between EMG root-mean-square (RMS) and ultrasound data of muscle thickness has been investigated using Response Surface Methodology in the muscles separately and together and predictive models reported. Results show that to assess the relationship between the changes of thickness and activity (EMG) in muscles, we can use quadratic model for the rectus femoris, tibialis anterior, transverse abdominal, biceps brachii and brachialis muscles (R 2 =0.624-0.891) and linear model for the internal and external oblique abdominal, lumbar multifidus and deep cervical flexor muscles (R 2 =0.348-0.767). Due to the high correlation coefficient for the equations in the bulky muscles, it seems that the correlation between EMG RMS and ultrasound data of muscle thickness on the bulky muscles is higher than the flat muscles. This relationship may depend more on the type of activity than the type of muscle. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  14. The Psychophysiology of Posttraumatic Stress Disorder: A Meta-Analysis

    ERIC Educational Resources Information Center

    Pole, Nnamdi

    2007-01-01

    This meta-analysis of 58 resting baseline studies, 25 startle studies, 17 standardized trauma cue studies, and 22 idiographic trauma cue studies compared adults with and without posttraumatic stress disorder (PTSD) on psychophysiological variables: facial electromyography (EMG), heart rate (HR), skin conductance (SC), and blood pressure.…

  15. Estimation of elbow flexion force during isometric muscle contraction from mechanomyography and electromyography.

    PubMed

    Youn, Wonkeun; Kim, Jung

    2010-11-01

    Mechanomyography (MMG) is the muscle surface oscillations that are generated by the dimensional change of the contracting muscle fibers. Because MMG reflects the number of recruited motor units and their firing rates, just as electromyography (EMG) is influenced by these two factors, it can be used to estimate the force exerted by skeletal muscles. The aim of this study was to demonstrate the feasibility of MMG for estimating the elbow flexion force at the wrist under an isometric contraction by using an artificial neural network in comparison with EMG. We performed experiments with five subjects, and the force at the wrist and the MMG from the contributing muscles were recorded. It was found that MMG could be utilized to accurately estimate the isometric elbow flexion force based on the values of the normalized root mean square error (NRMSE = 0.131 ± 0.018) and the cross-correlation coefficient (CORR = 0.892 ± 0.033). Although MMG can be influenced by the physical milieu/morphology of the muscle and EMG performed better than MMG, these experimental results suggest that MMG has the potential to estimate muscle forces. These experimental results also demonstrated that MMG in combination with EMG resulted in better performance estimation in comparison with EMG or MMG alone, indicating that a combination of MMG and EMG signals could be used to provide complimentary information on muscle contraction.

  16. Use of Chest Wall Electromyography to Detect Respiratory Effort during Polysomnography

    PubMed Central

    Berry, Richard B.; Ryals, Scott; Girdhar, Ankur; Wagner, Mary H.

    2016-01-01

    Study Objectives: To evaluate the ability of chest wall EMG (CW-EMG) using surface electrodes to classify apneas as obstructive, mixed, or central compared to classification using dual channel uncalibrated respiratory inductance plethysmography (RIP). Methods: CW-EMG was recorded from electrodes in the eighth intercostal space at the right mid-axillary line. Consecutive adult clinical sleep studies were retrospectively reviewed, and the first 60 studies with at least 10 obstructive and 10 mixed or central apneas and technically adequate tracings were selected. Four obstructive and six central or mixed apneas (as classified by previous clinical scoring) were randomly selected. A blinded experienced scorer classified the apneas on the basis of tracings showing either RIP channels or the CW-EMG channel. The agreement using the two classification methods was determined by kappa analysis and intraclass correlation. Results: The percentage agreement was 89.5%, the kappa statistic was 0.83 (95% confidence interval 0.79 to 0.87), and the intraclass correlation was 0.83, showing good agreement. Of the 249 apneas classified as central by RIP, 26 were classified as obstructive (10.4%) and 7 as mixed (2.8%) by CW-EMG. Of the 229 events classified as central by CW-EMG, 7 (3.1%) were classified as obstructive and 6 (2.6%) as mixed by RIP. Conclusions: Monitoring CW-EMG may provide a clinically useful method of detection of respiratory effort when used with RIP and can prevent false classification of apneas as central. RIP can rarely detect respiratory effort not easily discernible by CW-EMG and the combination of the two methods is more likely to avoid apnea misclassification. Citation: Berry RB, Ryals S, Girdhar A, Wagner MH. Use of chest wall electromyography to detect respiratory effort during polysomnography. J Clin Sleep Med 2016;12(9):1239–1244. PMID:27306391

  17. Reconstructing for joint angles on the shoulder and elbow from non-invasive electroencephalographic signals through electromyography

    PubMed Central

    Choi, Kyuwan

    2013-01-01

    In this study, first the cortical activities over 2240 vertexes on the brain were estimated from 64 channels electroencephalography (EEG) signals using the Hierarchical Bayesian estimation while 5 subjects did continuous arm reaching movements. From the estimated cortical activities, a sparse linear regression method selected only useful features in reconstructing the electromyography (EMG) signals and estimated the EMG signals of 9 arm muscles. Then, a modular artificial neural network was used to estimate four joint angles from the estimated EMG signals of 9 muscles: one for movement control and the other for posture control. The estimated joint angles using this method have the correlation coefficient (CC) of 0.807 (±0.10) and the normalized root-mean-square error (nRMSE) of 0.176 (±0.29) with the actual joint angles. PMID:24167469

  18. Neck surface electromyography as a measure of vocal hyperfunction before and after injection laryngoplasty

    PubMed Central

    Stepp, Cara E.; Heaton, James T.; Jetté, Marie E.; Burns, James A.; Hillman, Robert E.

    2012-01-01

    Objectives The goal of this preliminary study was to determine if neck surface electromyography (sEMG) is sensitive to possible changes in vocal hyperfunction associated with injection laryngoplasty, particularly with respect to alterations in the degree of vocal hyperfunction. Methods Thirteen individuals undergoing office-based injection laryngoplasty for glottal phonatory insufficiency were prospectively studied using a battery of acoustic, aerodynamic, endoscopic, and anterior neck surface electromyographic (sEMG) assessments before the procedure and approximately one week after. Results Anterior neck sEMG was not significantly reduced (p < 0.05) post-procedure; however, perceptual ratings of strain and false vocal fold (FVF) compression were both significantly reduced, reflecting a decrease in vocal hyperfunction. Conclusions The results do not support the use of anterior neck sEMG measures to assess vocal hyperfunction, and place into question the use of some other measures (estimates of anterior-posterior (AP) supraglottal compression, quantitative measures of AP and FVF supraglottal compression, and acoustic vowel rise times) that have been considered reflective of vocal hyperfunction. PMID:21033026

  19. Effects of 2 ankle destabilization devices on electromyography measures during functional exercises in individuals with chronic ankle instability.

    PubMed

    Donovan, Luke; Hart, Joseph M; Hertel, Jay

    2015-03-01

    Randomized crossover laboratory study. To determine the effects of ankle destabilization devices on surface electromyography (sEMG) measures of selected lower extremity muscles during functional exercises in participants with chronic ankle instability. Ankle destabilization devices are rehabilitation tools that can be worn as a boot or sandal to increase lower extremity muscle activation during walking in healthy individuals. However, they have not been tested in a population with pathology. Fifteen adults with chronic ankle instability participated. Surface electromyography electrodes were located over the anterior tibialis, fibularis longus, lateral gastrocnemius, rectus femoris, biceps femoris, and gluteus medius. The activity level of these muscles was recorded in a single testing session during unipedal stance with eyes closed, the Star Excursion Balance Test, lateral hops, and treadmill walking. Each task was performed under 3 conditions: shod, ankle destabilization boot, and ankle destabilization sandal. Surface electromyography signal amplitudes were measured for each muscle during each exercise for all 3 conditions. Participants demonstrated a significant increase, with moderate to large effect sizes, in sEMG signal amplitude of the fibularis longus in the ankle destabilization boot and ankle destabilization sandal conditions during the unipedal eyes-closed balance test, the Star Excursion Balance Test in the anterior and posteromedial directions, lateral hops, and walking, when compared to the shod condition. Both devices also resulted in an increase in sEMG signal amplitudes, with large effect sizes of the lateral gastrocnemius, rectus femoris, biceps femoris, and gluteus medius during the unipedal-stance-with-eyes-closed test, compared to the shod condition. Wearing ankle destabilization devices caused greater muscle activation during functional exercises in individuals with chronic ankle instability. Based on the magnitude of the effect, there were

  20. Motor unit potentials of the erector spinae muscle by concentric needle electromyography.

    PubMed

    Posa, Andreas; Niśkiewicz, Izabela; Emmer, Alexander; Kluge, Yorck; Kornhuber, Malte E

    2017-03-01

    The needle electromyography (EMG) serves to supply additional information in patients with suspected neuromuscular disorders. We aimed to provide motor unit potential (MUP) data by concentric needle EMG in the erector spinae (ES) in comparison with biceps brachii (BB) and lateral vastus (LV). Electromyography MUP data ( n ) were obtained in ES (517), BB (539), and LV (627) in 32 healthy volunteers (16f). Motor unit potential data: amplitude (μV) 393 ± 174 (ES), 375 ± 162 (BB), and 577 ± 304 (LV); duration (ms) 10.4 ± 2.4 (ES), 10.1 ± 2.1 (BB), and 11.1 ± 2.3 (LV), area (μV × ms) 585 ± 327 (ES), 538 ± 267 (BB), and 881 ± 492 (LV); phase number 3.23 ± 0.94 (ES), 2.98 ± 0.76 (BB), and 3.19 ± 0.81 (LV); size index 0.60 ± 0.56 (ES), 0.51 ± 0.53 (BB), and 0.96 ± 0.55 (LV). LV displayed higher values ( p at least <.001) for MUP amplitude, duration, area, and size index as compared to both, BB and ES. Concentric needle EMG investigations in healthy adult human subjects revealed similar MUP parameters in the ES and BB muscles, while in the LV muscle MUP amplitude, duration, area, and size index were significantly larger. Different neuromuscular disorders display a predominant involvement of proximally located muscles such as truncal muscles. The present results given here may facilitate the diagnosis of neuromuscular disorders.

  1. Applications of ICA and fractal dimension in sEMG signal processing for subtle movement analysis: a review.

    PubMed

    Naik, Ganesh R; Arjunan, Sridhar; Kumar, Dinesh

    2011-06-01

    The surface electromyography (sEMG) signal separation and decphompositions has always been an interesting research topic in the field of rehabilitation and medical research. Subtle myoelectric control is an advanced technique concerned with the detection, processing, classification, and application of myoelectric signals to control human-assisting robots or rehabilitation devices. This paper reviews recent research and development in independent component analysis and Fractal dimensional analysis for sEMG pattern recognition, and presents state-of-the-art achievements in terms of their type, structure, and potential application. Directions for future research are also briefly outlined.

  2. The Relationship Between Submental Surface Electromyography and Hyo-Laryngeal Kinematic Measures of Mendelsohn Maneuver Duration

    PubMed Central

    Azola, Alba M.; Greene, Lindsey R.; Taylor-Kamara, Isha; Macrae, Phoebe; Anderson, Cheryl

    2015-01-01

    Purpose The Mendelsohn Maneuver (MM) is a commonly prescribed technique that is taught to individuals with dysphagia to improve swallowing ability. Due to cost and safety concerns associated with videofluoroscopy (VFS) use, submental surface electromyography (ssEMG) is commonly used in place of VFS to train the MM in clinical and research settings. However, it is unknown whether ssEMG accurately reflects the prolonged hyo-laryngeal movements required for execution of the MM. The primary goal of this study was to examine the relationship among ssEMG duration, duration of laryngeal vestibule closure, and duration of maximum hyoid elevation during MM performance. Method Participants included healthy adults and patients with dysphagia due to stroke. All performed the MM during synchronous ssEMG and VFS recording. Results Significant correlations between ssEMG duration and VFS measures of hyo-laryngeal kinematic durations during MM performance ranged from very weak to moderate. None of the correlations in the group of stroke patients reached statistical significance. Conclusion Clinicians and researchers should consider that the MM involves novel hyo-laryngeal kinematics that may be only moderately represented with ssEMG. Thus, there is a risk that these target therapeutic movements are not consistently being trained. PMID:26426312

  3. The Feasibility of Hypnotic Analgesia in Ameliorating Pain and Anxiety Among Adults Undergoing Needle Electromyography

    PubMed Central

    Slack, David; Nelson, Lonnie; Patterson, David; Burns, Stephen; Hakimi, Kevin; Robinson, Lawrence

    2017-01-01

    Objective Our hypothesis was that hypnotic analgesia reduces pain and anxiety during electromyography [EMG]. Design Prospective randomized controlled clinical trial at outpatient electrodiagnostic clinics in teaching hospitals. Just prior to EMG, 26 subjects were randomized to one of three 20 minute audio programs: (EDU) education about EMG (n=8); (HYP-C) hypnotic induction without analgesic suggestion (n=10) or; (HYP-ANLG) hypnotic induction with analgesic suggestion (n=8). The blinded electromyographer provided a post-hypnotic suggestion at the start of EMG. After EMG, subjects rated worst and average pain, and anxiety using visual analog scales. Results Mean values for the EDU, HYP-C and HYP-ANLG groups were not significantly different (mean ± sd): worst pain 67 ± 25, 42 ± 18, 49 ± 30: average pain 35 ± 26, 27 ± 14, 25 ± 22; anxiety 44 ± 41, 42 ± 23, 22 ± 24. When hypnosis groups were merged [n=18] and compared with the EDU condition [n=8], average and worst pain and anxiety were less for the hypnosis group than EDU, but this was statistically significant only for worst pain [hypnosis - 46 ± 24 vs. EDU - 67 ± 35, p=0.049] with a 31% average reduction. Conclusions A short hypnotic induction appears to reduce worst pain during EMG. PMID:18971768

  4. Pattern learning with deep neural networks in EMG-based speech recognition.

    PubMed

    Wand, Michael; Schultz, Tanja

    2014-01-01

    We report on classification of phones and phonetic features from facial electromyographic (EMG) data, within the context of our EMG-based Silent Speech interface. In this paper we show that a Deep Neural Network can be used to perform this classification task, yielding a significant improvement over conventional Gaussian Mixture models. Our central contribution is the visualization of patterns which are learned by the neural network. With increasing network depth, these patterns represent more and more intricate electromyographic activity.

  5. Electromyography Biofeedback Exergames to Enhance Grip Strength and Motivation.

    PubMed

    Garcia-Hernandez, Nadia; Garza-Martinez, Karen; Parra-Vega, Vicente

    2018-02-01

    Hand strength weakness affects the performance of most activities of daily living. This study aims to design, develop, and test an electromyography (EMG) biofeedback training system based on serious games to promote motivation and synchronization and proper work intensity in grip exercises for improving hand strength. An EMG surface sensor, soft balls with different stiffness and three exergames, conforms the system to drive videogame clues in response to EMG-inferred grip strength, while overseeing motivation. An experiment was designed to study the effect of performing handgrip (HG) exercises with the proposed system versus traditional exercises. Participants, organized into two groups, followed a training program for each hand. One group followed a HG exergame training (ET) with the dominant hand and traditional HG training with the nondominant hand and inverse sequence by the second group. Initial and final grip forces were measured using a digital dynamometer. Questionnaires evaluated motivation and user experience, and exercise performance was evaluated in terms of work and rest time percentage and maximal voluntary contraction percentage over contraction periods. Data were analyzed for statistically significant differences and increase of means. Participants showed significantly better exercise performance and higher grip forces, with sustained intrinsic motivation and user experience, with the ET. Improvement in force level arises evidently from the synchronized work-rest time pattern and appropriated intensity of the muscle activity. This leads to support that EMG biofeedback exergames improve motor neurons firing and resting.

  6. State of the art review: Intravaginal probes for recording electromyography from the pelvic floor muscles.

    PubMed

    Keshwani, Nadia; McLean, Linda

    2015-02-01

    To survey commercially available intravaginal probes designed to record electromyography (EMG) from the pelvic floor muscles (PFMs), and to discuss the strengths and limitations of current technology. The MEDLINE EMBASE, CINAHL, PEDRO, and Cochrane databases were searched for articles in which intravaginal probes were described as having been used to record EMG from the PFMs. The World Wide Web was also searched using the Google search engine to find devices used to record EMG from the PFMs. Finally, a Canadian distributer of intravaginal probes was contacted to identify intravaginal EMG probes not identified through other methods. The specifications of each probe were determined through the manufacturer or their website, and each device was acquired by the investigators to verify the specifications and electrode configuration. The devices were evaluated against international standards for recording EMG data. Sixteen different models of commercially available intravaginal probes were identified: seven from published research papers, seven using the World Wide Web, and two through communication with a distributer. The probes vary in shape, dimensions, electrode positioning, and electrode configuration, with many designs prone to recording motion artifact, crosstalk, and/or inappropriate EMG signals. All commercially available intravaginal probes had deficiencies in their design such as problems with probe geometry, electrode size, location, and/or configuration. Improved intravaginal EMG probes should be developed for use in research and clinical practice. © 2013 Wiley Periodicals, Inc.

  7. The Effect of Varying Biting Position on Relative Jaw Muscle EMG activity

    DTIC Science & Technology

    1988-09-01

    with muscle force is the key to 13 this approach as it allows inference of muscle contraction activity from EMG data. This relationship has been the...5! 15 LITERATURE REVIEW Introduction: The study of the physiology of bite force, muscle contraction force, joint reaction force and the lever system...Currently, the best method of indirectly observing muscle contraction activity is through electromyography. Although there appears to be a time delay

  8. Impact of Functional Appliances on Muscle Activity: A Surface Electromyography Study in Children

    PubMed Central

    Woźniak, Krzysztof; Piątkowska, Dagmara; Szyszka-Sommerfeld, Liliana; Buczkowska-Radlińska, Jadwiga

    2015-01-01

    Background Electromyography (EMG) is the most objective tool for assessing changes in the electrical activity of the masticatory muscles. The purpose of the study was to evaluate the tone of the masseter and anterior temporalis muscles in growing children before and after 6 months of treatment with functional removable orthodontic appliances. Material/Methods The sample conisted of 51 patients with a mean age 10.7 years with Class II malocclusion. EMG recordings were performed by using a DAB-Bluetooth instrument (Zebris Medical GmbH, Germany). Recordings were performed in mandibular rest position, during maximum voluntary contraction (MVC), and during maximum effort. Results The results of the study indicated that the electrical activity of the muscles in each of the clinical situations was the same in the group of girls and boys. The factor that determined the activity of the muscles was their type. In mandibular rest position and in MVC, the activity of the temporalis muscles was significantly higher that that of the masseter muscels. The maximum effort test indicated a higher fatigue in masseter than in temporalis muscles. Conclusions Surface electromyography is a useful tool for monitoring muscle activity. A 6-month period of functional therapy resulted in changes in the activity of the masticatory muscles. PMID:25600247

  9. Comparison of sEMG processing methods during whole-body vibration exercise.

    PubMed

    Lienhard, Karin; Cabasson, Aline; Meste, Olivier; Colson, Serge S

    2015-12-01

    The objective was to investigate the influence of surface electromyography (sEMG) processing methods on the quantification of muscle activity during whole-body vibration (WBV) exercises. sEMG activity was recorded while the participants performed squats on the platform with and without WBV. The spikes observed in the sEMG spectrum at the vibration frequency and its harmonics were deleted using state-of-the-art methods, i.e. (1) a band-stop filter, (2) a band-pass filter, and (3) spectral linear interpolation. The same filtering methods were applied on the sEMG during the no-vibration trial. The linear interpolation method showed the highest intraclass correlation coefficients (no vibration: 0.999, WBV: 0.757-0.979) with the comparison measure (unfiltered sEMG during the no-vibration trial), followed by the band-stop filter (no vibration: 0.929-0.975, WBV: 0.661-0.938). While both methods introduced a systematic bias (P < 0.001), the error increased with increasing mean values to a higher degree for the band-stop filter. After adjusting the sEMG(RMS) during WBV for the bias, the performance of the interpolation method and the band-stop filter was comparable. The band-pass filter was in poor agreement with the other methods (ICC: 0.207-0.697), unless the sEMG(RMS) was corrected for the bias (ICC ⩾ 0.931, %LOA ⩽ 32.3). In conclusion, spectral linear interpolation or a band-stop filter centered at the vibration frequency and its multiple harmonics should be applied to delete the artifacts in the sEMG signals during WBV. With the use of a band-stop filter it is recommended to correct the sEMG(RMS) for the bias as this procedure improved its performance. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Effects of innovative virtual reality game and EMG biofeedback on neuromotor control in cerebral palsy.

    PubMed

    Yoo, Ji Won; Lee, Dong Ryul; Sim, Yon Ju; You, Joshua H; Kim, Cheol J

    2014-01-01

    Sensorimotor control dysfunction or dyskinesia is a hallmark of neuromuscular impairment in children with cerebral palsy (CP), and is often implicated in reaching and grasping deficiencies due to a neuromuscular imbalance between the triceps and biceps. To mitigate such muscle imbalances, an innovative electromyography (EMG)-virtual reality (VR) biofeedback system were designed to provide accurate information about muscle activation and motivation. However, the clinical efficacy of this approach has not yet been determined in children with CP. The purpose of this study was to investigate the effectiveness of a combined EMG biofeedback and VR (EMG-VR biofeedback) intervention system to improve muscle imbalance between triceps and biceps during reaching movements in children with spastic CP. Raw EMG signals were recorded at a sampling rate of 1,000 Hz, band-pass filtered between 20-450 Hz, and notch-filtered at 60 Hz during elbow flexion and extension movements. EMG data were then processed using MyoResearch Master Edition 1.08 XP software. All participants underwent both interventions consisting of the EMG-VR biofeedback combination and EMG biofeedback alone. EMG analysis resulted in improved muscle activation in the underactive triceps while decreasing overactive or hypertonic biceps in the EMG-VR biofeedback compared with EMG biofeedback. The muscle imbalance ratio between the triceps and biceps was consistently improved. The present study is the first clinical trial to provide evidence for the additive benefits of VR intervention for enhancing the upper limb function of children with spastic CP.

  11. A canonical correlation analysis based EMG classification algorithm for eliminating electrode shift effect.

    PubMed

    Zhe Fan; Zhong Wang; Guanglin Li; Ruomei Wang

    2016-08-01

    Motion classification system based on surface Electromyography (sEMG) pattern recognition has achieved good results in experimental condition. But it is still a challenge for clinical implement and practical application. Many factors contribute to the difficulty of clinical use of the EMG based dexterous control. The most obvious and important is the noise in the EMG signal caused by electrode shift, muscle fatigue, motion artifact, inherent instability of signal and biological signals such as Electrocardiogram. In this paper, a novel method based on Canonical Correlation Analysis (CCA) was developed to eliminate the reduction of classification accuracy caused by electrode shift. The average classification accuracy of our method were above 95% for the healthy subjects. In the process, we validated the influence of electrode shift on motion classification accuracy and discovered the strong correlation with correlation coefficient of >0.9 between shift position data and normal position data.

  12. One-Channel Surface Electromyography Decomposition for Muscle Force Estimation.

    PubMed

    Sun, Wentao; Zhu, Jinying; Jiang, Yinlai; Yokoi, Hiroshi; Huang, Qiang

    2018-01-01

    Estimating muscle force by surface electromyography (sEMG) is a non-invasive and flexible way to diagnose biomechanical diseases and control assistive devices such as prosthetic hands. To estimate muscle force using sEMG, a supervised method is commonly adopted. This requires simultaneous recording of sEMG signals and muscle force measured by additional devices to tune the variables involved. However, recording the muscle force of the lost limb of an amputee is challenging, and the supervised method has limitations in this regard. Although the unsupervised method does not require muscle force recording, it suffers from low accuracy due to a lack of reference data. To achieve accurate and easy estimation of muscle force by the unsupervised method, we propose a decomposition of one-channel sEMG signals into constituent motor unit action potentials (MUAPs) in two steps: (1) learning an orthogonal basis of sEMG signals through reconstruction independent component analysis; (2) extracting spike-like MUAPs from the basis vectors. Nine healthy subjects were recruited to evaluate the accuracy of the proposed approach in estimating muscle force of the biceps brachii. The results demonstrated that the proposed approach based on decomposed MUAPs explains more than 80% of the muscle force variability recorded at an arbitrary force level, while the conventional amplitude-based approach explains only 62.3% of this variability. With the proposed approach, we were also able to achieve grip force control of a prosthetic hand, which is one of the most important clinical applications of the unsupervised method. Experiments on two trans-radial amputees indicated that the proposed approach improves the performance of the prosthetic hand in grasping everyday objects.

  13. Detecting Nasal Vowels in Speech Interfaces Based on Surface Electromyography

    PubMed Central

    Freitas, João; Teixeira, António; Silva, Samuel; Oliveira, Catarina; Dias, Miguel Sales

    2015-01-01

    Nasality is a very important characteristic of several languages, European Portuguese being one of them. This paper addresses the challenge of nasality detection in surface electromyography (EMG) based speech interfaces. We explore the existence of useful information about the velum movement and also assess if muscles deeper down in the face and neck region can be measured using surface electrodes, and the best electrode location to do so. The procedure we adopted uses Real-Time Magnetic Resonance Imaging (RT-MRI), collected from a set of speakers, providing a method to interpret EMG data. By ensuring compatible data recording conditions, and proper time alignment between the EMG and the RT-MRI data, we are able to accurately estimate the time when the velum moves and the type of movement when a nasal vowel occurs. The combination of these two sources revealed interesting and distinct characteristics in the EMG signal when a nasal vowel is uttered, which motivated a classification experiment. Overall results of this experiment provide evidence that it is possible to detect velum movement using sensors positioned below the ear, between mastoid process and the mandible, in the upper neck region. In a frame-based classification scenario, error rates as low as 32.5% for all speakers and 23.4% for the best speaker have been achieved, for nasal vowel detection. This outcome stands as an encouraging result, fostering the grounds for deeper exploration of the proposed approach as a promising route to the development of an EMG-based speech interface for languages with strong nasal characteristics. PMID:26069968

  14. An EMG-Controlled Robotic Hand Exoskeleton for Bilateral Rehabilitation.

    PubMed

    Leonardis, Daniele; Barsotti, Michele; Loconsole, Claudio; Solazzi, Massimiliano; Troncossi, Marco; Mazzotti, Claudio; Castelli, Vincenzo Parenti; Procopio, Caterina; Lamola, Giuseppe; Chisari, Carmelo; Bergamasco, Massimo; Frisoli, Antonio

    2015-01-01

    This paper presents a novel electromyography (EMG)-driven hand exoskeleton for bilateral rehabilitation of grasping in stroke. The developed hand exoskeleton was designed with two distinctive features: (a) kinematics with intrinsic adaptability to patient's hand size, and (b) free-palm and free-fingertip design, preserving the residual sensory perceptual capability of touch during assistance in grasping of real objects. In the envisaged bilateral training strategy, the patient's non paretic hand acted as guidance for the paretic hand in grasping tasks. Grasping force exerted by the non paretic hand was estimated in real-time from EMG signals, and then replicated as robotic assistance for the paretic hand by means of the hand-exoskeleton. Estimation of the grasping force through EMG allowed to perform rehabilitation exercises with any, non sensorized, graspable objects. This paper presents the system design, development, and experimental evaluation. Experiments were performed within a group of six healthy subjects and two chronic stroke patients, executing robotic-assisted grasping tasks. Results related to performance in estimation and modulation of the robotic assistance, and to the outcomes of the pilot rehabilitation sessions with stroke patients, positively support validity of the proposed approach for application in stroke rehabilitation.

  15. Surface EMG signals based motion intent recognition using multi-layer ELM

    NASA Astrophysics Data System (ADS)

    Wang, Jianhui; Qi, Lin; Wang, Xiao

    2017-11-01

    The upper-limb rehabilitation robot is regard as a useful tool to help patients with hemiplegic to do repetitive exercise. The surface electromyography (sEMG) contains motion information as the electric signals are generated and related to nerve-muscle motion. These sEMG signals, representing human's intentions of active motions, are introduced into the rehabilitation robot system to recognize upper-limb movements. Traditionally, the feature extraction is an indispensable part of drawing significant information from original signals, which is a tedious task requiring rich and related experience. This paper employs a deep learning scheme to extract the internal features of the sEMG signals using an advanced Extreme Learning Machine based auto-encoder (ELMAE). The mathematical information contained in the multi-layer structure of the ELM-AE is used as the high-level representation of the internal features of the sEMG signals, and thus a simple ELM can post-process the extracted features, formulating the entire multi-layer ELM (ML-ELM) algorithm. The method is employed for the sEMG based neural intentions recognition afterwards. The case studies show the adopted deep learning algorithm (ELM-AE) is capable of yielding higher classification accuracy compared to the Principle Component Analysis (PCA) scheme in 5 different types of upper-limb motions. This indicates the effectiveness and the learning capability of the ML-ELM in such motion intent recognition applications.

  16. Compression of high-density EMG signals for trapezius and gastrocnemius muscles.

    PubMed

    Itiki, Cinthia; Furuie, Sergio S; Merletti, Roberto

    2014-03-10

    New technologies for data transmission and multi-electrode arrays increased the demand for compressing high-density electromyography (HD EMG) signals. This article aims the compression of HD EMG signals recorded by two-dimensional electrode matrices at different muscle-contraction forces. It also shows methodological aspects of compressing HD EMG signals for non-pinnate (upper trapezius) and pinnate (medial gastrocnemius) muscles, using image compression techniques. HD EMG signals were placed in image rows, according to two distinct electrode orders: parallel and perpendicular to the muscle longitudinal axis. For the lossless case, the images obtained from single-differential signals as well as their differences in time were compressed. For the lossy algorithm, the images associated to the recorded monopolar or single-differential signals were compressed for different compression levels. Lossless compression provided up to 59.3% file-size reduction (FSR), with lower contraction forces associated to higher FSR. For lossy compression, a 90.8% reduction on the file size was attained, while keeping the signal-to-noise ratio (SNR) at 21.19 dB. For a similar FSR, higher contraction forces corresponded to higher SNR CONCLUSIONS: The computation of signal differences in time improves the performance of lossless compression while the selection of signals in the transversal order improves the lossy compression of HD EMG, for both pinnate and non-pinnate muscles.

  17. Compression of high-density EMG signals for trapezius and gastrocnemius muscles

    PubMed Central

    2014-01-01

    Background New technologies for data transmission and multi-electrode arrays increased the demand for compressing high-density electromyography (HD EMG) signals. This article aims the compression of HD EMG signals recorded by two-dimensional electrode matrices at different muscle-contraction forces. It also shows methodological aspects of compressing HD EMG signals for non-pinnate (upper trapezius) and pinnate (medial gastrocnemius) muscles, using image compression techniques. Methods HD EMG signals were placed in image rows, according to two distinct electrode orders: parallel and perpendicular to the muscle longitudinal axis. For the lossless case, the images obtained from single-differential signals as well as their differences in time were compressed. For the lossy algorithm, the images associated to the recorded monopolar or single-differential signals were compressed for different compression levels. Results Lossless compression provided up to 59.3% file-size reduction (FSR), with lower contraction forces associated to higher FSR. For lossy compression, a 90.8% reduction on the file size was attained, while keeping the signal-to-noise ratio (SNR) at 21.19 dB. For a similar FSR, higher contraction forces corresponded to higher SNR Conclusions The computation of signal differences in time improves the performance of lossless compression while the selection of signals in the transversal order improves the lossy compression of HD EMG, for both pinnate and non-pinnate muscles. PMID:24612604

  18. An Analysis of EMG Electrode Configuration for Targeted Muscle Reinnervation Based Neural Machine Interface

    PubMed Central

    Huang, He; Zhou, Ping; Li, Guanglin; Kuiken, Todd A.

    2015-01-01

    Targeted muscle reinnervation (TMR) is a novel neural machine interface for improved myoelectric prosthesis control. Previous high-density (HD) surface electromyography (EMG) studies have indicated that tremendous neural control information can be extracted from the reinnervated muscles by EMG pattern recognition (PR). However, using a large number of EMG electrodes hinders clinical application of the TMR technique. This study investigated a reduced number of electrodes and the placement required to extract sufficient neural control information for accurate identification of user movement intents. An electrode selection algorithm was applied to the HD EMG recordings from each of 4 TMR amputee subjects. The results show that when using only 12 selected bipolar electrodes the average accuracy over subjects for classifying 16 movement intents was 93.0(±3.3)%, just 1.2% lower than when using the entire HD electrode complement. The locations of selected electrodes were consistent with the anatomical reinnervation sites. Additionally, a practical protocol for clinical electrode placement was developed, which does not rely on complex HD EMG experiment and analysis while maintaining a classification accuracy of 88.7±4.5%. These outcomes provide important guidelines for practical electrode placement that can promote future clinical application of TMR and EMG PR in the control of multifunctional prostheses. PMID:18303804

  19. Analysis of statistical and standard algorithms for detecting muscle onset with surface electromyography

    PubMed Central

    Tweedell, Andrew J.; Haynes, Courtney A.

    2017-01-01

    The timing of muscle activity is a commonly applied analytic method to understand how the nervous system controls movement. This study systematically evaluates six classes of standard and statistical algorithms to determine muscle onset in both experimental surface electromyography (EMG) and simulated EMG with a known onset time. Eighteen participants had EMG collected from the biceps brachii and vastus lateralis while performing a biceps curl or knee extension, respectively. Three established methods and three statistical methods for EMG onset were evaluated. Linear envelope, Teager-Kaiser energy operator + linear envelope and sample entropy were the established methods evaluated while general time series mean/variance, sequential and batch processing of parametric and nonparametric tools, and Bayesian changepoint analysis were the statistical techniques used. Visual EMG onset (experimental data) and objective EMG onset (simulated data) were compared with algorithmic EMG onset via root mean square error and linear regression models for stepwise elimination of inferior algorithms. The top algorithms for both data types were analyzed for their mean agreement with the gold standard onset and evaluation of 95% confidence intervals. The top algorithms were all Bayesian changepoint analysis iterations where the parameter of the prior (p0) was zero. The best performing Bayesian algorithms were p0 = 0 and a posterior probability for onset determination at 60–90%. While existing algorithms performed reasonably, the Bayesian changepoint analysis methodology provides greater reliability and accuracy when determining the singular onset of EMG activity in a time series. Further research is needed to determine if this class of algorithms perform equally well when the time series has multiple bursts of muscle activity. PMID:28489897

  20. Analysis of statistical and standard algorithms for detecting muscle onset with surface electromyography.

    PubMed

    Tenan, Matthew S; Tweedell, Andrew J; Haynes, Courtney A

    2017-01-01

    The timing of muscle activity is a commonly applied analytic method to understand how the nervous system controls movement. This study systematically evaluates six classes of standard and statistical algorithms to determine muscle onset in both experimental surface electromyography (EMG) and simulated EMG with a known onset time. Eighteen participants had EMG collected from the biceps brachii and vastus lateralis while performing a biceps curl or knee extension, respectively. Three established methods and three statistical methods for EMG onset were evaluated. Linear envelope, Teager-Kaiser energy operator + linear envelope and sample entropy were the established methods evaluated while general time series mean/variance, sequential and batch processing of parametric and nonparametric tools, and Bayesian changepoint analysis were the statistical techniques used. Visual EMG onset (experimental data) and objective EMG onset (simulated data) were compared with algorithmic EMG onset via root mean square error and linear regression models for stepwise elimination of inferior algorithms. The top algorithms for both data types were analyzed for their mean agreement with the gold standard onset and evaluation of 95% confidence intervals. The top algorithms were all Bayesian changepoint analysis iterations where the parameter of the prior (p0) was zero. The best performing Bayesian algorithms were p0 = 0 and a posterior probability for onset determination at 60-90%. While existing algorithms performed reasonably, the Bayesian changepoint analysis methodology provides greater reliability and accuracy when determining the singular onset of EMG activity in a time series. Further research is needed to determine if this class of algorithms perform equally well when the time series has multiple bursts of muscle activity.

  1. Cross-Correlation of Motor Activity Signals from dc-Magnetoencephalography, Near-Infrared Spectroscopy, and Electromyography

    PubMed Central

    Sander, Tilmann H.; Leistner, Stefanie; Wabnitz, Heidrun; Mackert, Bruno-Marcel; Macdonald, Rainer; Trahms, Lutz

    2010-01-01

    Neuronal and vascular responses due to finger movements were synchronously measured using dc-magnetoencephalography (dcMEG) and time-resolved near-infrared spectroscopy (trNIRS). The finger movements were monitored with electromyography (EMG). Cortical responses related to the finger movement sequence were extracted by independent component analysis from both the dcMEG and the trNIRS data. The temporal relations between EMG rate, dcMEG, and trNIRS responses were assessed pairwise using the cross-correlation function (CCF), which does not require epoch averaging. A positive lag on a scale of seconds was found for the maximum of the CCF between dcMEG and trNIRS. A zero lag is observed for the CCF between dcMEG and EMG. Additionally this CCF exhibits oscillations at the frequency of individual finger movements. These findings show that the dcMEG with a bandwidth up to 8 Hz records both slow and faster neuronal responses, whereas the vascular response is confirmed to change on a scale of seconds. PMID:20145717

  2. Cross-correlation of motor activity signals from dc-magnetoencephalography, near-infrared spectroscopy, and electromyography.

    PubMed

    Sander, Tilmann H; Leistner, Stefanie; Wabnitz, Heidrun; Mackert, Bruno-Marcel; Macdonald, Rainer; Trahms, Lutz

    2010-01-01

    Neuronal and vascular responses due to finger movements were synchronously measured using dc-magnetoencephalography (dcMEG) and time-resolved near-infrared spectroscopy (trNIRS). The finger movements were monitored with electromyography (EMG). Cortical responses related to the finger movement sequence were extracted by independent component analysis from both the dcMEG and the trNIRS data. The temporal relations between EMG rate, dcMEG, and trNIRS responses were assessed pairwise using the cross-correlation function (CCF), which does not require epoch averaging. A positive lag on a scale of seconds was found for the maximum of the CCF between dcMEG and trNIRS. A zero lag is observed for the CCF between dcMEG and EMG. Additionally this CCF exhibits oscillations at the frequency of individual finger movements. These findings show that the dcMEG with a bandwidth up to 8 Hz records both slow and faster neuronal responses, whereas the vascular response is confirmed to change on a scale of seconds.

  3. Electromyography findings of the cricopharyngeus in association with ipsilateral pharyngeal and laryngeal muscles.

    PubMed

    Halum, Stacey L; Shemirani, Nima L; Merati, Albert L; Jaradeh, Safwan; Toohill, Robert J

    2006-04-01

    We reviewed a large series of cricopharyngeal (CP) muscle electromyography (EMG) results and compared them with the EMG results from the inferior constrictor (IC), thyroarytenoid, (TA), cricothyroid (CT), and posterior cricoarytenoid (PCA) muscles. We performed a retrospective review of all CP muscle EMG reports from studies performed between January 1996 and June 2003. All of the tested elements from the CP muscle EMG reports were recorded. The EMG results were recorded for the ipsilateral IC, TA, CT, and PCA muscles if they were simultaneously tested. Each muscle result was classified as normal, neurogenic inactive axonal injury (IAI), or neurogenic active axonal injury (AAI), and the muscle findings were compared. A patient chart review was performed to determine a clinical correlation. Fifty-nine patients underwent CP muscle EMG. Eighteen patients had bilateral EMG studies, making a total of 77 CP muscle studies. Nineteen sets of CP muscle results were normal, 43 demonstrated neurogenic IAI, and 15 demonstrated neurogenic AAI. The ipsilateral IC and CP muscles had the same innervation status in 27 of 28 studies (p < .0001). When the ipsilateral TA muscle was studied simultaneously with the CP muscle, 31 of 50 studies had the same innervation status (p = .005). The ipsilateral CT and CP muscles demonstrated the same innervation status in 40 of 50 studies (p < .0001). The correlations between the CP and IC muscle findings and between the CP and CT muscle findings were both stronger than the correlation between the CP and TA muscle findings (p < .0001 and p = .024, respectively). The chart review demonstrated the clinical findings to be consistent with the EMG results. The EMG studies demonstrated that CP muscle findings have the strongest correlation with IC muscle findings, followed by the CT and TA muscles. This outcome does not support theories indicating that the recurrent laryngeal nerve innervates the CP muscle in all cases.

  4. Effectiveness of the Wavelet Transform on the Surface EMG to Understand the Muscle Fatigue During Walk

    NASA Astrophysics Data System (ADS)

    Hussain, M. S.; Mamun, Md.

    2012-01-01

    Muscle fatigue is the decline in ability of a muscle to create force. Electromyography (EMG) is a medical technique for measuring muscle response to nervous stimulation. During a sustained muscle contraction, the power spectrum of the EMG shifts towards lower frequencies. These effects are due to muscle fatigue. Muscle fatigue is often a result of unhealthy work practice. In this research, the effectiveness of the wavelet transform applied to the surface EMG (SEMG) signal as a means of understanding muscle fatigue during walk is presented. Power spectrum and bispectrum analysis on the EMG signal getting from right rectus femoris muscle is executed utilizing various wavelet functions (WFs). It is possible to recognize muscle fatigue appreciably with the proper choice of the WF. The outcome proves that the most momentous changes in the EMG power spectrum are symbolized by WF Daubechies45. Moreover, this research has compared bispectrum properties to the other WFs. To determine muscle fatigue during gait, Daubechies45 is used in this research to analyze the SEMG signal.

  5. Multi-step EMG Classification Algorithm for Human-Computer Interaction

    NASA Astrophysics Data System (ADS)

    Ren, Peng; Barreto, Armando; Adjouadi, Malek

    A three-electrode human-computer interaction system, based on digital processing of the Electromyogram (EMG) signal, is presented. This system can effectively help disabled individuals paralyzed from the neck down to interact with computers or communicate with people through computers using point-and-click graphic interfaces. The three electrodes are placed on the right frontalis, the left temporalis and the right temporalis muscles in the head, respectively. The signal processing algorithm used translates the EMG signals during five kinds of facial movements (left jaw clenching, right jaw clenching, eyebrows up, eyebrows down, simultaneous left & right jaw clenching) into five corresponding types of cursor movements (left, right, up, down and left-click), to provide basic mouse control. The classification strategy is based on three principles: the EMG energy of one channel is typically larger than the others during one specific muscle contraction; the spectral characteristics of the EMG signals produced by the frontalis and temporalis muscles during different movements are different; the EMG signals from adjacent channels typically have correlated energy profiles. The algorithm is evaluated on 20 pre-recorded EMG signal sets, using Matlab simulations. The results show that this method provides improvements and is more robust than other previous approaches.

  6. A Novel Unsupervised Adaptive Learning Method for Long-Term Electromyography (EMG) Pattern Recognition.

    PubMed

    Huang, Qi; Yang, Dapeng; Jiang, Li; Zhang, Huajie; Liu, Hong; Kotani, Kiyoshi

    2017-06-13

    Performance degradation will be caused by a variety of interfering factors for pattern recognition-based myoelectric control methods in the long term. This paper proposes an adaptive learning method with low computational cost to mitigate the effect in unsupervised adaptive learning scenarios. We presents a particle adaptive classifier (PAC), by constructing a particle adaptive learning strategy and universal incremental least square support vector classifier (LS-SVC). We compared PAC performance with incremental support vector classifier (ISVC) and non-adapting SVC (NSVC) in a long-term pattern recognition task in both unsupervised and supervised adaptive learning scenarios. Retraining time cost and recognition accuracy were compared by validating the classification performance on both simulated and realistic long-term EMG data. The classification results of realistic long-term EMG data showed that the PAC significantly decreased the performance degradation in unsupervised adaptive learning scenarios compared with NSVC (9.03% ± 2.23%, p < 0.05) and ISVC (13.38% ± 2.62%, p = 0.001), and reduced the retraining time cost compared with ISVC (2 ms per updating cycle vs. 50 ms per updating cycle).

  7. Wrist torque estimation during simultaneous and continuously changing movements: surface vs. untargeted intramuscular EMG.

    PubMed

    Kamavuako, Ernest N; Scheme, Erik J; Englehart, Kevin B

    2013-06-01

    In this paper, the predictive capability of surface and untargeted intramuscular electromyography (EMG) was compared with respect to wrist-joint torque to quantify which type of measurement better represents joint torque during multiple degrees-of-freedom (DoF) movements for possible application in prosthetic control. Ten able-bodied subjects participated in the study. Surface and intramuscular EMG was recorded concurrently from the right forearm. The subjects were instructed to track continuous contraction profiles using single and combined DoF in two trials. The association between torque and EMG was assessed using an artificial neural network. Results showed a significant difference between the two types of EMG (P < 0.007) for all performance metrics: coefficient of determination (R(2)), Pearson correlation coefficient (PCC), and root mean square error (RMSE). The performance of surface EMG (R(2) = 0.93 ± 0.03; PCC = 0.98 ± 0.01; RMSE = 8.7 ± 2.1%) was found to be superior compared with intramuscular EMG (R(2) = 0.80 ± 0.07; PCC = 0.93 ± 0.03; RMSE = 14.5 ± 2.9%). The higher values of PCC compared with R(2) indicate that both methods are able to track the torque profile well but have some trouble (particularly intramuscular EMG) in estimating the exact amplitude. The possible cause for the difference, thus the low performance of intramuscular EMG, may be attributed to the very high selectivity of the recordings used in this study.

  8. Can surface electromyography improve surgery planning? Electromyographic assessment and intraoperative verification of the nerve bundle entry point location of the gracilis muscle.

    PubMed

    Romaniszyn, Michal; Walega, Piotr; Nowakowski, Michal; Nowak, Wojciech

    2016-06-01

    To verify the precision of surface electromyography (sEMG) in locating the innervation zone of the gracilis muscle, by comparing the location of the IZ estimated by means of sEMG with in vivo location of the nerve bundle entry point in patients before graciloplasty procedure due to fecal incontinence. Nine patients who qualified for the graciloplasty procedure underwent sEMG on both gracilis muscle before their operations. During surgery the nerve bundle was identified by means of electrical stimulation. The distance between the proximal attachment and the nerve entry point into the muscle's body was measured. Both measurements (sEMG and in vivo identification) were compared for each subject. On average, the IZ was located 65.5mm from the proximal attachment. The mean difference in location of the innervation zones in each individual was 10±9.7mm, maximal - 30mm, the difference being statistically significant (p=0.017). It was intraoperatively confirmed, that the nerve entered the muscle an average of 62mm from the proximal attachment. The largest difference between the EMG IZ estimation and nerve bundle entry point was 5mm (mean difference 2.8mm, p=0.767). Preoperative surface electromyography of both gracilis muscles is a safe, precise and reliable method of assessing the location of the innervation zones of the gracilis muscles. The asymmetry of the IZ location in left and right muscles may be important in context of technical aspects of the graciloplasty procedure. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Robust Features Of Surface Electromyography Signal

    NASA Astrophysics Data System (ADS)

    Sabri, M. I.; Miskon, M. F.; Yaacob, M. R.

    2013-12-01

    Nowadays, application of robotics in human life has been explored widely. Robotics exoskeleton system are one of drastically areas in recent robotic research that shows mimic impact in human life. These system have been developed significantly to be used for human power augmentation, robotics rehabilitation, human power assist, and haptic interaction in virtual reality. This paper focus on solving challenges in problem using neural signals and extracting human intent. Commonly, surface electromyography signal (sEMG) are used in order to control human intent for application exoskeleton robot. But the problem lies on difficulty of pattern recognition of the sEMG features due to high noises which are electrode and cable motion artifact, electrode noise, dermic noise, alternating current power line interface, and other noise came from electronic instrument. The main objective in this paper is to study the best features of electromyography in term of time domain (statistical analysis) and frequency domain (Fast Fourier Transform).The secondary objectives is to map the relationship between torque and best features of muscle unit activation potential (MaxPS and RMS) of biceps brachii. This project scope use primary data of 2 male sample subject which using same dominant hand (right handed), age between 20-27 years old, muscle diameter 32cm to 35cm and using single channel muscle (biceps brachii muscle). The experiment conduct 2 times repeated task of contraction and relaxation of biceps brachii when lifting different load from no load to 3kg with ascending 1kg The result shows that Fast Fourier Transform maximum power spectrum (MaxPS) has less error than mean value of reading compare to root mean square (RMS) value. Thus, Fast Fourier Transform maximum power spectrum (MaxPS) show the linear relationship against torque experience by elbow joint to lift different load. As the conclusion, the best features is MaxPS because it has the lowest error than other features and show

  10. Experiences in the creation of an electromyography database to help hand amputated persons.

    PubMed

    Atzori, Manfredo; Gijsberts, Arjan; Heynen, Simone; Hager, Anne-Gabrielle Mittaz; Castellimi, Claudio; Caputo, Barbara; Müller, Henning

    2012-01-01

    Currently, trans-radial amputees can only perform a few simple movements with prosthetic hands. This is mainly due to low control capabilities and the long training time that is required to learn controlling them with surface electromyography (sEMG). This is in contrast with recent advances in mechatronics, thanks to which mechanical hands have multiple degrees of freedom and in some cases force control. To help improve the situation, we are building the NinaPro (Non-Invasive Adaptive Prosthetics) database, a database of about 50 hand and wrist movements recorded from several healthy and currently very few amputated persons that will help the community to test and improve sEMG-based natural control systems for prosthetic hands. In this paper we describe the experimental experiences and practical aspects related to the data acquisition.

  11. Augmented effects of EMG biofeedback interfaced with virtual reality on neuromuscular control and movement coordination during reaching in children with cerebral palsy.

    PubMed

    Yoo, Ji Won; Lee, Dong Ryul; Cha, Young Joo; You, Sung Hyun

    2017-01-01

    The purpose of the present study was to compare therapeutic effects of an electromyography (EMG) biofeedback augmented by virtual reality (VR) and EMG biofeedback alone on the triceps and biceps (T:B) muscle activity imbalance and elbow joint movement coordination during a reaching motor taskOBJECTIVE: To compare therapeutic effects of an electromyography (EMG) biofeedback augmented by virtual reality (VR) and EMG biofeedback alone on the triceps and biceps muscle activity imbalance and elbow joint movement coordination during a reaching motor task in normal children and children with spastic cerebral palsy (CP). 18 children with spastic CP (2 females; mean±standard deviation = 9.5 ± 1.96 years) and 8 normal children (3 females; mean ± standard deviation = 9.75 ± 2.55 years) were recruited from a local community center. All children with CP first underwent one intensive session of EMG feedback (30 minutes), followed by one session of the EMG-VR feedback (30 minutes) after a 1-week washout period. Clinical tests included elbow extension range of motion (ROM), biceps muscle strength, and box and block test. EMG triceps and biceps (T:B) muscle activity imbalance and reaching movement acceleration coordination were concurrently determined by EMG and 3-axis accelerometer measurements respectively. Independent t-test and one-way repeated analysis of variance (ANOVA) were performed at p < 0.05. The one-way repeated ANOVA was revealed to be significantly effective in elbow extension ROM (p = 0.01), biceps muscle strength (p = 0.01), and box and block test (p = 0.03). The one-way repeated ANOVA also revealed to be significantly effective in the peak triceps muscle activity (p = 0.01). However, one-way repeated ANOVA produced no statistical significance in the composite 3-dimensional movement acceleration coordination data (p = 0.12). The present study is a first clinical trial that demonstrated the superior benefits of the EMG biofeedback

  12. A Novel Unsupervised Adaptive Learning Method for Long-Term Electromyography (EMG) Pattern Recognition

    PubMed Central

    Huang, Qi; Yang, Dapeng; Jiang, Li; Zhang, Huajie; Liu, Hong; Kotani, Kiyoshi

    2017-01-01

    Performance degradation will be caused by a variety of interfering factors for pattern recognition-based myoelectric control methods in the long term. This paper proposes an adaptive learning method with low computational cost to mitigate the effect in unsupervised adaptive learning scenarios. We presents a particle adaptive classifier (PAC), by constructing a particle adaptive learning strategy and universal incremental least square support vector classifier (LS-SVC). We compared PAC performance with incremental support vector classifier (ISVC) and non-adapting SVC (NSVC) in a long-term pattern recognition task in both unsupervised and supervised adaptive learning scenarios. Retraining time cost and recognition accuracy were compared by validating the classification performance on both simulated and realistic long-term EMG data. The classification results of realistic long-term EMG data showed that the PAC significantly decreased the performance degradation in unsupervised adaptive learning scenarios compared with NSVC (9.03% ± 2.23%, p < 0.05) and ISVC (13.38% ± 2.62%, p = 0.001), and reduced the retraining time cost compared with ISVC (2 ms per updating cycle vs. 50 ms per updating cycle). PMID:28608824

  13. INCREASED VOLUNTARY DRIVE IS ASSOCIATED WITH CHANGES IN COMMON OSCILLATIONS FROM 13 TO 60 HZ OF INTERFERENCE BUT NOT RECTIFIED ELECTROMYOGRAPHY

    PubMed Central

    NETO, OSMAR P.; BAWEJA, HARSIMRAN S.; CHRISTOU, EVANGELOS A.

    2013-01-01

    The purpose of this study was to compare the capability of interference and rectified electromyography (EMG) to detect changes in the beta (13–30-HZ) and Piper (30–60-HZ) bands when voluntary force is increased. Twenty adults exerted a constant force abduction of the index finger at 15% and 50% of maximum. The common oscillations at various frequency bands (0–500 HZ) were estimated from the first dorsal interosseous muscle using cross wavelets of interference and rectified EMG. For the interference EMG signals, normalized power significantly (P < 0.01) increased with force in the beta (9.0 ± 0.9 vs. 15.5 ± 2.1%) and Piper (13.6 ± 0.9 vs. 21 ± 1.7%) bands. For rectified EMG signals, however, the beta and Piper bands remained unchanged (P > 0.4). Although rectified EMG is used in many clinical studies to identify changes in the oscillatory drive to the muscle, our findings suggest that only interference EMG can accurately capture the increase in oscillatory drive from 13 to 60 HZ with voluntary force. PMID:20589885

  14. Treatment efficacy of electromyography versus fiberscopy-guided botulinum toxin injection in adductor spasmodic dysphonia patients: a prospective comparative study.

    PubMed

    Kim, Jae Wook; Park, Jae Hong; Park, Ki Nam; Lee, Seung Won

    2014-01-01

    This study prospectively evaluates and compares the treatment efficacy of botulinum toxin injection under electromyography guidance (EMG group) and percutaneous botulinum toxin injection under flexible fiberscopic guidance (fiberscopy group). Thirty patients with adductor spasmodic dysphonia (ADSD), who had never received treatment, were randomly allocated into EMG- or fiberscopy-guided botulinum toxin injections between March 2008 and February 2010. We assessed acoustic and aerodynamic voice parameters, and the voice handicap index (VHI) before injection and at 1, 3, and 6 months after injection. The mean total dosage of botulinum toxin was similar for both groups: 1.7 ± 0.5 U for the EMG group and 1.8 ± 0.4 U for the fiberscopy group (P > 0.05). There were no significant differences in outcomes between the two groups in either the duration of effectiveness or complications such as breathy voice and aspiration. Botulinum toxin injection under fiberscopic guidance is a viable alternative to EMG-guided botulinum toxin injection for the treatment of adductor spasmodic dysphonia when EMG equipment is unavailable.

  15. Treatment Efficacy of Electromyography versus Fiberscopy-Guided Botulinum Toxin Injection in Adductor Spasmodic Dysphonia Patients: A Prospective Comparative Study

    PubMed Central

    Kim, Jae Wook; Park, Jae Hong; Park, Ki Nam; Lee, Seung Won

    2014-01-01

    Introduction. This study prospectively evaluates and compares the treatment efficacy of botulinum toxin injection under electromyography guidance (EMG group) and percutaneous botulinum toxin injection under flexible fiberscopic guidance (fiberscopy group). Methods. Thirty patients with adductor spasmodic dysphonia (ADSD), who had never received treatment, were randomly allocated into EMG- or fiberscopy-guided botulinum toxin injections between March 2008 and February 2010. We assessed acoustic and aerodynamic voice parameters, and the voice handicap index (VHI) before injection and at 1, 3, and 6 months after injection. Results. The mean total dosage of botulinum toxin was similar for both groups: 1.7 ± 0.5 U for the EMG group and 1.8 ± 0.4 U for the fiberscopy group (P > 0.05). There were no significant differences in outcomes between the two groups in either the duration of effectiveness or complications such as breathy voice and aspiration. Conclusion. Botulinum toxin injection under fiberscopic guidance is a viable alternative to EMG-guided botulinum toxin injection for the treatment of adductor spasmodic dysphonia when EMG equipment is unavailable. PMID:25383369

  16. Bilinear modeling of EMG signals to extract user-independent features for multiuser myoelectric interface.

    PubMed

    Matsubara, Takamitsu; Morimoto, Jun

    2013-08-01

    In this study, we propose a multiuser myoelectric interface that can easily adapt to novel users. When a user performs different motions (e.g., grasping and pinching), different electromyography (EMG) signals are measured. When different users perform the same motion (e.g., grasping), different EMG signals are also measured. Therefore, designing a myoelectric interface that can be used by multiple users to perform multiple motions is difficult. To cope with this problem, we propose for EMG signals a bilinear model that is composed of two linear factors: 1) user dependent and 2) motion dependent. By decomposing the EMG signals into these two factors, the extracted motion-dependent factors can be used as user-independent features. We can construct a motion classifier on the extracted feature space to develop the multiuser interface. For novel users, the proposed adaptation method estimates the user-dependent factor through only a few interactions. The bilinear EMG model with the estimated user-dependent factor can extract the user-independent features from the novel user data. We applied our proposed method to a recognition task of five hand gestures for robotic hand control using four-channel EMG signals measured from subject forearms. Our method resulted in 73% accuracy, which was statistically significantly different from the accuracy of standard nonmultiuser interfaces, as the result of a two-sample t -test at a significance level of 1%.

  17. The Stroop matching task presents conflict at both the response and nonresponse levels: an event-related potential and electromyography study.

    PubMed

    Caldas, A L; Machado-Pinheiro, W; Souza, L B; Motta-Ribeiro, G C; David, I A

    2012-09-01

    In the Stroop matching task, a Stroop word is compared to a colored bar. The origin of the conflict presented by this task is a topic of current debate. In an effort to disentangle nonresponse and response conflicts, we recorded electromyography (EMG) and event-related potentials (ERPs) while participants performed the task. The N450 component was sensitive to the relationship of color surfaces, regardless of the response, suggesting the participation of nonresponse conflict. Incompatible arrays (e.g., incongruent Stroop stimuli during "same" responses) presented a substantial amount of double EMG activation and slower EMG latencies, suggesting the participation of response conflict. We propose that both response and nonresponse conflicts are sources of these effects. The combined use of the EMG and ERP techniques played an important role in elucidating the conflicts immersed in the Stroop matching task. Copyright © 2012 Society for Psychophysiological Research.

  18. Estimation of distal arm joint angles from EMG and shoulder orientation for transhumeral prostheses.

    PubMed

    Akhtar, Aadeel; Aghasadeghi, Navid; Hargrove, Levi; Bretl, Timothy

    2017-08-01

    In this paper, we quantify the extent to which shoulder orientation, upper-arm electromyography (EMG), and forearm EMG are predictors of distal arm joint angles during reaching in eight subjects without disability as well as three subjects with a unilateral transhumeral amputation and targeted reinnervation. Prior studies have shown that shoulder orientation and upper-arm EMG, taken separately, are predictors of both elbow flexion/extension and forearm pronation/supination. We show that, for eight subjects without disability, shoulder orientation and upper-arm EMG together are a significantly better predictor of both elbow flexion/extension during unilateral (R 2 =0.72) and mirrored bilateral (R 2 =0.72) reaches and of forearm pronation/supination during unilateral (R 2 =0.77) and mirrored bilateral (R 2 =0.70) reaches. We also show that adding forearm EMG further improves the prediction of forearm pronation/supination during unilateral (R 2 =0.82) and mirrored bilateral (R 2 =0.75) reaches. In principle, these results provide the basis for choosing inputs for control of transhumeral prostheses, both by subjects with targeted motor reinnervation (when forearm EMG is available) and by subjects without target motor reinnervation (when forearm EMG is not available). In particular, we confirm that shoulder orientation and upper-arm EMG together best predict elbow flexion/extension (R 2 =0.72) for three subjects with unilateral transhumeral amputations and targeted motor reinnervation. However, shoulder orientation alone best predicts forearm pronation/supination (R 2 =0.88) for these subjects, a contradictory result that merits further study. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Electromyography-based analysis of human upper limbs during 45-day head-down bed-rest

    NASA Astrophysics Data System (ADS)

    Fu, Anshuang; Wang, Chunhui; Qi, Hongzhi; Li, Fan; Wang, Zheng; He, Feng; Zhou, Peng; Chen, Shanguang; Ming, Dong

    2016-03-01

    Muscle deconditioning occurs in response to simulated or actual microgravity. In spaceflight, astronauts become monkey-like for mainly using their upper limbs to control the operating system and to complete corresponding tasks. The changes of upper limbs' athletic ability will directly affect astronauts' working performance. This study investigated the variation trend of surface electromyography (sEMG) during prolonged simulated microgravity. Eight healthy males participating in this study performed strict 45-day head-down bed-rest (HDBR). On the 5th day of pre-HDBR, and the 15th, the 30th and the 45th days of HDBR, the subjects performed maximum pushing task and maximum pulling task, and sEMG was collected from upper limbs synchronously. Each subject's maximum volunteer contractions of both the tasks during these days were compared, showing no significant change. However, changes were detected by sEMG-based analysis. It was found that integrated EMG, root mean square, mean frequency, fuzzy entropy of deltoid, and fuzzy entropy of triceps brachii changed significantly when comparing pre-HDBR with HDBR. The variation trend showed a recovery tendency after significant decline, which is inconsistent with the monotonic variation of lower limbs that was proved by previous research. These findings suggest that EMG changes in upper limbs during prolonged simulated microgravity, but has different variation trend from lower limbs.

  20. An Analysis of Intrinsic and Extrinsic Hand Muscle EMG for Improved Pattern Recognition Control.

    PubMed

    Adewuyi, Adenike A; Hargrove, Levi J; Kuiken, Todd A

    2016-04-01

    Pattern recognition control combined with surface electromyography (EMG) from the extrinsic hand muscles has shown great promise for control of multiple prosthetic functions for transradial amputees. There is, however, a need to adapt this control method when implemented for partial-hand amputees, who possess both a functional wrist and information-rich residual intrinsic hand muscles. We demonstrate that combining EMG data from both intrinsic and extrinsic hand muscles to classify hand grasps and finger motions allows up to 19 classes of hand grasps and individual finger motions to be decoded, with an accuracy of 96% for non-amputees and 85% for partial-hand amputees. We evaluated real-time pattern recognition control of three hand motions in seven different wrist positions. We found that a system trained with both intrinsic and extrinsic muscle EMG data, collected while statically and dynamically varying wrist position increased completion rates from 73% to 96% for partial-hand amputees and from 88% to 100% for non-amputees when compared to a system trained with only extrinsic muscle EMG data collected in a neutral wrist position. Our study shows that incorporating intrinsic muscle EMG data and wrist motion can significantly improve the robustness of pattern recognition control for application to partial-hand prosthetic control.

  1. An Analysis of Intrinsic and Extrinsic Hand Muscle EMG for Improved Pattern Recognition Control

    PubMed Central

    Adewuyi, Adenike A.; Hargrove, Levi J.; Kuiken, Todd A.

    2015-01-01

    Pattern recognition control combined with surface electromyography (EMG) from the extrinsic hand muscles has shown great promise for control of multiple prosthetic functions for transradial amputees. There is, however, a need to adapt this control method when implemented for partial-hand amputees, who possess both a functional wrist and information-rich residual intrinsic hand muscles. We demonstrate that combining EMG data from both intrinsic and extrinsic hand muscles to classify hand grasps and finger motions allows up to 19 classes of hand grasps and individual finger motions to be decoded, with an accuracy of 96% for non-amputees and 85% for partial-hand amputees. We evaluated real-time pattern recognition control of three hand motions in seven different wrist positions. We found that a system trained with both intrinsic and extrinsic muscle EMG data, collected while statically and dynamically varying wrist position increased completion rates from 73% to 96% for partial-hand amputees and from 88% to 100% for non-amputees when compared to a system trained with only extrinsic muscle EMG data collected in a neutral wrist position. Our study shows that incorporating intrinsic muscle EMG data and wrist motion can significantly improve the robustness of pattern recognition control for partial-hand applications. PMID:25955989

  2. The effects of whole body vibration on EMG activity of the upper extremity muscles in static modified push up position.

    PubMed

    Ashnagar, Zinat; Shadmehr, Azadeh; Hadian, Mohammadreza; Talebian, Saeed; Jalaei, Shohreh

    2016-08-10

    Whole Body Vibration (WBV) has been reported to change neuromuscular activity which indirectly assessed by electromyography (EMG). Although researches regarding the influence of WBV on EMG activity of the upper extremity muscles are in their infancy, contradictory findings have been reported as a result of dissimilar protocols. The purpose of this study was to investigate the effects of WBV on electromyography (EMG) activity of upper extremity muscles in static modified push up position. Forty recreationally active females were randomly assigned in WBV and control groups. Participants in WBV group received 5 sets of 30 seconds vibration at 5 mm (peak to peak) and 30 Hz by using vibratory platform. No vibration stimulus was used in the control group. Surface EMG was recorded from Upper Trapezius (UT), Serratus Anterior (SA), Biceps Brachii (BB) and Triceps Brachii (TB) muscles before, during and after the vibration protocol while the subjects maintained the static modified push up position. EMG signals were expressed as root mean square (EMGrms) and normalized by maximum voluntary exertion (MVE). EMGrms activity of the studied muscles increased significantly during the vibration protocol in the WBV group comparing to the control group (P ≤ 0.05). The results indicated that vibration stimulus transmitting via hands increased muscle activity of UT, SA, BB and TB muscles by an average of 206%, 60%, 106% and 120%, respectively, comparing to pre vibration values. These findings suggest that short exposure to the WBV could increase the EMGrms activity of the upper extremity muscles in the static modified push-up position. However, more sessions of WBV application require for a proper judgment.

  3. Blink Prosthesis For Facial Paralysis Patients

    DTIC Science & Technology

    2016-10-01

    predisposes patients to corneal exposure and dry eye complications that are difficult to effectively treat. The proposed innovation will provide a...aesthetic and functional use of the paralyzed eyelid by preventing painful dry eye complications and profound facial disfiguration. The goal of this program... eye blink in patients with unilateral facial nerve paralysis. The system will electrically stimulate the paretic eyelid when EMG electrodes detect

  4. Characteristics and significance of doublets on needle EMG.

    PubMed

    Lamb, Christopher J; Rubin, Devon I

    2017-04-01

    Voluntary doublets are electrophysiological phenomena thought to be associated with metabolic derangements or neuromuscular conditions. We prospectively studied 232 consecutive patients examined by a single examiner during routine electromyography (EMG) to determine the frequency of doublets in individual patients, specific muscles, neuromuscular conditions, electrolyte levels, and doublet characteristics. Of 232 patients, 25 (10.7%) exhibited doublets. The mean age was 59 (52% men). Only 32 of 1,303 (2.5%) muscles exhibited doublets. Lower extremity and paraspinal groups represented 91% of muscles with doublets. Doublet frequency grouped by EMG diagnoses was: ALS (3 of 11; 27.1%), myopathy (3 of 10; 30.0%), axonal polyneuropathy (7 of 29; 24.1%), and no disease (7 of 109; 6.4%). There were no differences in serum electrolytes between doublet and matched subjects. Doublets occur in approximately 10% of patients, more commonly in lower extremity and paraspinal muscles, and are not correlated with a specific metabolic abnormality or neuromuscular condition. Muscle Nerve 55: 598-600, 2017. © 2016 Wiley Periodicals, Inc.

  5. Selective stimulation of facial muscles with a penetrating electrode array in the feline model

    PubMed Central

    Sahyouni, Ronald; Bhatt, Jay; Djalilian, Hamid R.; Tang, William C.; Middlebrooks, John C.; Lin, Harrison W.

    2017-01-01

    Objective Permanent facial nerve injury is a difficult challenge for both patients and physicians given its potential for debilitating functional, cosmetic, and psychological sequelae. Although current surgical interventions have provided considerable advancements in facial nerve rehabilitation, they often fail to fully address all impairments. We aim to introduce an alternative approach to facial nerve rehabilitation. Study design Acute experiments in animals with normal facial function. Methods The study included three anesthetized cats. Four facial muscles (levator auris longus, orbicularis oculi, nasalis, and orbicularis oris) were monitored with a standard electromyographic (EMG) facial nerve monitoring system with needle electrodes. The main trunk of the facial nerve was exposed and a 16-channel penetrating electrode array was placed into the nerve. Electrical current pulses were delivered to each stimulating electrode individually. Elicited EMG voltage outputs were recorded for each muscle. Results Stimulation through individual channels selectively activated restricted nerve populations, resulting in selective contraction of individual muscles. Increasing stimulation current levels resulted in increasing EMG voltage responses. Typically, selective activation of two or more distinct muscles was successfully achieved via a single placement of the multi-channel electrode array by selection of appropriate stimulation channels. Conclusion We have established in the animal model the ability of a penetrating electrode array to selectively stimulate restricted fiber populations within the facial nerve and to selectively elicit contractions in specific muscles and regions of the face. These results show promise for the development of a facial nerve implant system. PMID:27312936

  6. Organization of the central control of muscles of facial expression in man

    PubMed Central

    Root, A A; Stephens, J A

    2003-01-01

    Surface EMGs were recorded simultaneously from ipsilateral pairs of facial muscles while subjects made three different common facial expressions: the smile, a sad expression and an expression of horror, and three contrived facial expressions. Central peaks were found in the cross-correlograms of EMG activity recorded from the orbicularis oculi and zygomaticus major during smiling, the corrugator and depressor anguli oris during the sad look and the frontalis and mentalis during the horror look. The size of the central peak was significantly greater between the orbicularis oculi and zygomaticus major during smiling. It is concluded that co-contraction of facial muscles during some facial expressions are accompanied by the presence of common synaptic drive to the motoneurones supplying the muscles involved. Central peaks were found in the cross-correlograms of EMG activity recorded from the frontalis and depressor anguli oris during a contrived expression. However, no central peaks were found in the cross-correlograms of EMG activity recorded from the frontalis and orbicularis oculi or from the frontalis and zygomaticus major during the other two contrived expressions. It is concluded that a common synaptic drive is not present between all possible facial muscle pairs and suggests a functional role for the synergy. The origin of the common drive is discussed. It is concluded that activity in branches of common stem last-order presynaptic input fibres to motoneurones innervating the different facial muscles and presynaptic synchronization of input activity to the different motoneurone pools is involved. The former probably contributes more to the drive to the orbicularis oculi and zygomaticus major during smiling, while the latter is probably more prevalent in the corrugator and depressor anguli oris during the sad look, the frontalis and mentalis during the horror look and the frontalis and depressor anguli oris during one of the contrived expressions. The strength

  7. Measurement of EMG activity with textile electrodes embedded into clothing.

    PubMed

    Finni, T; Hu, M; Kettunen, P; Vilavuo, T; Cheng, S

    2007-11-01

    Novel textile electrodes that can be embedded into sports clothing to measure averaged rectified electromyography (EMG) have been developed for easy use in field tests and in clinical settings. The purpose of this study was to evaluate the validity, reliability and feasibility of this new product to measure averaged rectified EMG. The validity was tested by comparing the signals from bipolar textile electrodes (42 cm(2)) and traditional bipolar surface electrodes (1.32 cm(2)) during bilateral isometric knee extension exercise with two electrode locations (A: both electrodes located in the same place, B: traditional electrodes placed on the individual muscles according to SENIAM, n=10 persons for each). Within-session repeatability (the coefficient of variation CV%, n=10) was calculated from five repetitions of 60% maximum voluntary contraction (MVC). The day-to-day repeatability (n=8) was assessed by measuring three different isometric force levels on five consecutive days. The feasibility of the textile electrodes in field conditions was assessed during a maximal treadmill test (n=28). Bland-Altman plots showed a good agreement within 2SD between the textile and traditional electrodes, demonstrating that the textile electrodes provide similar information on the EMG signal amplitude to the traditional electrodes. The within-session CV ranged from 13% to 21% in both the textile and traditional electrodes. The day-to-day CV was smaller, ranging from 4% to 11% for the textile electrodes. A similar relationship (r(2)=0.5) was found between muscle strength and the EMG of traditional and textile electrodes. The feasibility study showed that the textile electrode technique can potentially make EMG measurements very easy in field conditions. This study indicates that textile electrodes embedded into shorts is a valid and feasible method for assessing the average rectified value of EMG.

  8. Quantifying Forearm Muscle Activity during Wrist and Finger Movements by Means of Multi-Channel Electromyography

    PubMed Central

    Gazzoni, Marco; Celadon, Nicolò; Mastrapasqua, Davide; Paleari, Marco; Margaria, Valentina; Ariano, Paolo

    2014-01-01

    The study of hand and finger movement is an important topic with applications in prosthetics, rehabilitation, and ergonomics. Surface electromyography (sEMG) is the gold standard for the analysis of muscle activation. Previous studies investigated the optimal electrode number and positioning on the forearm to obtain information representative of muscle activation and robust to movements. However, the sEMG spatial distribution on the forearm during hand and finger movements and its changes due to different hand positions has never been quantified. The aim of this work is to quantify 1) the spatial localization of surface EMG activity of distinct forearm muscles during dynamic free movements of wrist and single fingers and 2) the effect of hand position on sEMG activity distribution. The subjects performed cyclic dynamic tasks involving the wrist and the fingers. The wrist tasks and the hand opening/closing task were performed with the hand in prone and neutral positions. A sensorized glove was used for kinematics recording. sEMG signals were acquired from the forearm muscles using a grid of 112 electrodes integrated into a stretchable textile sleeve. The areas of sEMG activity have been identified by a segmentation technique after a data dimensionality reduction step based on Non Negative Matrix Factorization applied to the EMG envelopes. The results show that 1) it is possible to identify distinct areas of sEMG activity on the forearm for different fingers; 2) hand position influences sEMG activity level and spatial distribution. This work gives new quantitative information about sEMG activity distribution on the forearm in healthy subjects and provides a basis for future works on the identification of optimal electrode configuration for sEMG based control of prostheses, exoskeletons, or orthoses. An example of use of this information for the optimization of the detection system for the estimation of joint kinematics from sEMG is reported. PMID:25289669

  9. Quantitative Evaluation of Electrodes for External Urethral Sphincter Electromyography during Bladder-to-Urethral Guarding Reflex

    PubMed Central

    Steward, James E.; Clemons, Jessica D.; Zaszczurynski, Paul J.; Butler, Robert S.; Damaser, Margot S.; Jiang, Hai-Hong

    2009-01-01

    Purpose Accuracy in the recording of external urethral sphincter (EUS) electromyography (EMG) is an important goal in the quantitative evaluation of urethral function. This study aim was to quantitatively compare electrode recordings taken during tonic activity and leak point pressure (LPP) testing. Methods Several electrodes, including the surface electrode (SE), concentric electrode (CE), and wire electrode (WE), were placed on the EUS singly and simultaneously in six female Sprague-Dawley rats under urethane anesthesia. The bladder was filled via a retropubic catheter while LPP testing and EUS EMG recording were done. Quantitative baseline correction of the EUS EMG signal was performed to reduce baseline variation. Amplitude and frequency of one-second samples of the EUS EMG signal were measured before LPP (tonic activity) and during peak LPP activity. Results The SE, CE, and WE signals demonstrated tonic activity before LPP and an increase in activity during LPP, suggesting that the electrodes accurately recorded EUS activity during tonic activity and during the bladder-to-EUS guarding reflex, regardless of the size or location of detection areas. SE recordings required significantly less baseline correction than both CE and WE recordings. The activity in CE-recorded EMG was significantly higher than that of the SE and WE both in single and simultaneous recordings. Conclusions These electrodes may be suitable for testing EUS EMG activity. The SE signal had significantly less baseline variation and the CE detected local activity more sensitively than the other electrodes, which may provide insight into choosing an appropriate electrode for EUS EMG recording. PMID:19680661

  10. Comparison of six electromyography acquisition setups on hand movement classification tasks.

    PubMed

    Pizzolato, Stefano; Tagliapietra, Luca; Cognolato, Matteo; Reggiani, Monica; Müller, Henning; Atzori, Manfredo

    2017-01-01

    Hand prostheses controlled by surface electromyography are promising due to the non-invasive approach and the control capabilities offered by machine learning. Nevertheless, dexterous prostheses are still scarcely spread due to control difficulties, low robustness and often prohibitive costs. Several sEMG acquisition setups are now available, ranging in terms of costs between a few hundred and several thousand dollars. The objective of this paper is the relative comparison of six acquisition setups on an identical hand movement classification task, in order to help the researchers to choose the proper acquisition setup for their requirements. The acquisition setups are based on four different sEMG electrodes (including Otto Bock, Delsys Trigno, Cometa Wave + Dormo ECG and two Thalmic Myo armbands) and they were used to record more than 50 hand movements from intact subjects with a standardized acquisition protocol. The relative performance of the six sEMG acquisition setups is compared on 41 identical hand movements with a standardized feature extraction and data analysis pipeline aimed at performing hand movement classification. Comparable classification results are obtained with three acquisition setups including the Delsys Trigno, the Cometa Wave and the affordable setup composed of two Myo armbands. The results suggest that practical sEMG tests can be performed even when costs are relevant (e.g. in small laboratories, developing countries or use by children). All the presented datasets can be used for offline tests and their quality can easily be compared as the data sets are publicly available.

  11. Social hierarchies and emotions: cortical prefrontal activity, facial feedback (EMG), and cognitive performance in a dynamic interaction.

    PubMed

    Balconi, Michela; Pagani, Silvia

    2015-04-01

    In the present research, we manipulated the perceived superior/inferior status during a competitive cognitive task. In two experiments, we created an explicit and strongly reinforced social hierarchy based on incidental rating on an attentional task. Based on our hypotheses, social rank may influence nonverbal cues (such as facial mimic related to emotional response), cortical lateralized activity in frontal areas (brain oscillations), and cognitive outcomes in response to rank modulation. Thus, the facial mimic (corrugators vs. zygomatic muscle activity), frequency bands (delta, theta, alpha, beta), and real cognitive performance [(error rate (ER); response times (RTs)] were considered. Specifically, a peer-group comparison was enrolled and an improved (experiment 1, N = 29) or decreased (experiment 2, N = 31) performance was artificially manipulated by the experimenter. Results showed a significant improved cognitive performance (decreased ER and RTs), an increased zygomatic activity (positive emotions), and a more prefrontal left-lateralized cortical response in the case of a perceived increased social ranking. On the contrary, a significant decreased cognitive performance (increased ER and RTs), an increased corrugators activity (negative emotions), and a less left-lateralized cortical response were observed as a consequence of a perceived decreased social ranking. Moreover, the correlational values revealed a consistent trend between behavioral (RTs) and EMG and EEG measures for both experiments. The present results suggest that social status not only guides social behavior, but it also influences cognitive processes and subjects' performance.

  12. Surface electromyography as a screening method for evaluation of dysphagia and odynophagia

    PubMed Central

    Vaiman, Michael; Eviatar, Ephraim

    2009-01-01

    Objective Patients suspected of having swallowing disorders, could highly benefit from simple diagnostic screening before being referred to specialist evaluations. The article analyzes various instrumental methods of dysphagia assessment, introduces surface electromyography (sEMG) to carry out rapid assessment of such patients, and debates proposed suggestions for sEMG screening protocol in order to identify abnormal deglutition. Data sources Subject related books and articles from 1813 to 2007 were obtained through library search, MEDLINE (1949–2007) and EMBASE (1975–2007). Methods Specifics steps for establishing the protocol for applying the technique for screening purposes (e.g., evaluation of specific muscles), the requirements for diagnostic sEMG equipment, the sEMG technique itself, and defining the tests suitable for assessing deglutition (e.g., saliva, normal, and excessive swallows and uninterrupted drinking of water) are presented in detail. SEMG is compared with other techniques in terms of cost, timing, involvement of radiation, etc. Results According to the published data, SEMG of swallowing is a simple and reliable method for screening and preliminary differentiation among dysphagia and odynophagia of various origins. This noninvasive radiation-free examination has a low level of discomfort, and is simple, time-saving and inexpensive to perform. The major weakness of the method seems to be inability for precise diagnostic of neurologically induced dysphagia. Conclusion With standardization of the technique and an established normative database, sEMG might serve as a reliable screening method for optimal patient management but cannot serve for proper investigation of neurogenic dysphagia. PMID:19232090

  13. The Efficacy of Two Treatment Techniques for Children with Spastic Cerebral Palsy as Measured by Electromyography and Thermal Information. [Final Report.

    ERIC Educational Resources Information Center

    Finn, David Michael

    Two techniques to normalize muscle tone were evaluated with nine infants and young children with cerebral palsy who were enrolled in the Rural Infant Stimulation Environment (RISE) Program, near Tuscaloosa, Alabama. Electromyography (EMG) and skin temperature data were used to assess the effects of trunk rotation and slow rolling on a ball. EMG…

  14. Comparison of kinemyography and electromyography during spontaneous recovery from non-depolarising neuromuscular blockade.

    PubMed

    Khandkar, C; Liang, S; Phillips, S; Lee, C Y; Stewart, P A

    2016-11-01

    This study compared two commercially available quantitative neuromuscular function monitoring techniques, kinemyography (KMG) and electromyography (EMG), to assess whether KMG could be used interchangeably with EMG to exclude residual neuromuscular blockade (RNMB). Train-of-four (TOF) ratios were recorded every 20 seconds using KMG at the adductor pollicis and EMG at the first dorsal interosseous of the same hand during spontaneous recovery from shallow neuromuscular blockade. TOF ratios were compared using Bland-Altman analysis for repeated measurements. The precision of each device was assessed by the repeatability coefficient. Agreement between devices was assessed by the bias and limits of agreement. Clinically acceptable agreement was defined as a bias <0.025 within limits of agreement ±0.05. We recorded 629 sets of TOF ratios from 23 patients. The repeatability coefficient for KMG was 0.05 (95% confidence interval [CI] 0.05 to 0.06) and for EMG 0.10 (95% CI 0.10 to 0.11). Overall, the bias of KMG TOF ratios against EMG TOF ratios was 0.11 (95% CI 0.10 to 0.12), with limits of agreement -0.11 to 0.32. In the 0.80 to 0.99 TOF range, the bias was 0.08 (95% CI 0.06 to 0.09) and the limits of agreement were -0.12 to 0.27. Overall, TOF ratios measured by KMG were on average 0.11 higher than EMG. In the 0.80 to 0.99 TOF range, KMG TOF ratios were 0.08 higher. EMG and KMG are not interchangeable because the bias is large and the limits of agreement are wide. Thus a maximum TOF ratio of 1.0 on KMG may not exclude RNMB.

  15. [Orofacial alterations and surface electromyography in neurodevelopmental disorders].

    PubMed

    Rosell-Clari, V

    2017-02-24

    Surface electromyography has become a widely used technique for measuring the activity of different muscle groups. Although the reliability and validity of the technique are discussed, there is an important body of scientific literature that defends the use of this technique. To present through a case study, the two basic uses of surface electromyography: the measurement of orofacial muscular activity and use it as biofeedback modulator of the muscular activity itself. A 10 years-old girl with a dolichocephalic and prognosis facial profile, anterior open bite and bilateral cross bite, bilateral Angle class II occlusion and atypical swallowing with lingual interposition. The MioTool Face by Miotec Suite 1.0, it could use until 8-channel bipolar surface electromyography. Surface electrodes were placed in the orofacial musculature and the results obtained were measured and visualized through the software Miograph and Biotrainer. The results confirm those obtained through the clinical exploration of the patient and support the use of these measurements for the estimation and validation of mechanical models of the masticatory and swallowing system. Electromyographic biofeedback is shown as an effective technique to self-control the force performed in key muscle groups by performing primary activities such as chewing and swallowing.

  16. [Application of surface electromyography in the treatment of adolescent idiopathic scoliosis with traditional spinal balanced therapy].

    PubMed

    Du, Hong-Gen; Ye, Shu-Liang; Xu, Jin-Yuan; Jiang, Zhong; Song, Hong-Quan; Yu, Ji-Wei

    2013-11-01

    To evaluate the values of surface electromyography (sEMG) in the treatment of adolescent idiophathic scoliosis (AIS) with non-surgical therapy. From October 2011 to May 2012, the data of 33 patients with AIS underwent traditional spinal balanced therapy were analyzed. There were 14 males and 19 females with an average age of (15.40 +/- 3.01) years,ranging in Cobb angle from 13 degrees to 40 degrees, course of disease more than 3 months. X-rays showed 21 cases were type C and 9 cases were type S. Preoperative and postoperative 6 months, Cobb angle, the ratio of averaged electromyography paramete (AEMG), security of treatment were observed. Thirty cases (90.9%) accomplished the treatment and detection. No harmful effects to vital sign was found and no fracture, dislocation, apopsychia, infection of pin hole was found. There was positive correlation between the ratio of AEMG and Cobb angle (P = 0.003). The ratio of AEMG decreased after treatment,and indicated the improvement of myosthenic otherness. sEMG can be used as a objective examination in evaluating difference of muscle electricity activity on both concaved and convex sides for patients of AIS, so it is a qualified objective examination for effectiveness evaluation and assessment aggravation risk, and has great value in clinic.

  17. Influence of post-stroke spasticity on EMG-force coupling and force steadiness in biceps brachii.

    PubMed

    Carlyle, Jennilee K; Mochizuki, George

    2018-02-01

    Individuals with spasticity after stroke experience a decrease in force steadiness which can impact function. Alterations in the strength of EMG-force coupling may contribute to the reduction in force steadiness observed in spasticity. The aim was to determine the extent to which force steadiness and EMG-force coupling is affected by post-stroke spasticity. This cross-sectional study involved individuals with upper limb spasticity after stroke. Participants were required to generate and maintain isometric contractions of the elbow flexors at varying force levels. Coefficient of variation of force, absolute force, EMG-force cross-correlation function peak and peak latency was measured from both limbs with surface electromyography and isometric dynamometry. Statistically significant differences were observed between the affected and less affected limbs for all outcome measures. Significant main effects of force level were also observed. Force steadiness was not statistically significantly correlated with EMG-force coupling; however, both force steadiness and absolute force were associated with the level of impairment as measured by the Chedoke McMaster Stroke Assessment Scale. Spasticity after stroke uncouples the relationship between EMG and force and is associated with reduced force steadiness during isometric contractions; however, these features of control are not associated in individuals with spasticity. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Multichannel noninvasive human-machine interface via stretchable µm thick sEMG patches for robot manipulation

    NASA Astrophysics Data System (ADS)

    Zhou, Ying; Wang, Youhua; Liu, Runfeng; Xiao, Lin; Zhang, Qin; Huang, YongAn

    2018-01-01

    Epidermal electronics (e-skin) emerging in recent years offer the opportunity to noninvasively and wearably extract biosignals from human bodies. The conventional processes of e-skin based on standard microelectronic fabrication processes and a variety of transfer printing methods, nevertheless, unquestionably constrains the size of the devices, posing a serious challenge to collecting signals via skin, the largest organ in the human body. Herein we propose a multichannel noninvasive human-machine interface (HMI) using stretchable surface electromyography (sEMG) patches to realize a robot hand mimicking human gestures. Time-efficient processes are first developed to manufacture µm thick large-scale stretchable devices. With micron thickness, the stretchable µm thick sEMG patches show excellent conformability with human skin and consequently comparable electrical performance with conventional gel electrodes. Combined with the large-scale size, the multichannel noninvasive HMI via stretchable µm thick sEMG patches successfully manipulates the robot hand with eight different gestures, whose precision is as high as conventional gel electrodes array.

  19. Uterine electromyography during active phase compared with latent phase of labor at term.

    PubMed

    Trojner Bregar, Andreja; Lucovnik, Miha; Verdenik, Ivan; Jager, Franc; Gersak, Ksenija; Garfield, Robert E

    2016-02-01

    In a prospective study in a tertiary university hospital we wanted to determine whether uterine electromyography (EMG) can differentiate between the active and latent phase of labor. Thirty women presenting at ≥37(0/7) weeks of gestation with regular uterine contractions, intact membranes, and a Bishop score <6. EMG was recorded from the abdominal surface for 30 min. Latent phase was defined as no cervical change within at least 4 h. Student's t-test was used for statistical analysis (p ≤ 0.05 significant). Diagnostic accuracy of EMG was determined by receiver operator characteristics (ROC) analysis. The integral of the amplitudes of the power density spectrum (PDS) corresponding to the PDS energy within the "bursts" of uterine EMG activity was compared between the active and latent labor groups. Seventeen (57%) women were found to be in the active phase of labor and 13 (43%) were in the latent phase. The EMG PDS integral was significantly higher (p = 0.02) in the active (mean 3.40 ± 0.82 μV) compared with the latent (mean 1.17 ± 0.33 μV) phase of labor. The PDS integral had an area under the ROC curve (AUC) of 0.80 to distinguish between active and latent phases of labor, compared with number of contractions on tocodynamometry (AUC = 0.79), and Bishop score (AUC = 0.78). The combination (sum) of PDS integral, tocodynamometry, and Bishop score predicted active phase of labor with an AUC of 0.90. Adding uterine EMG measurements to the methods currently used in the clinics could improve the accuracy of diagnosing active labor. © 2015 Nordic Federation of Societies of Obstetrics and Gynecology.

  20. Hand Motion Classification Using a Multi-Channel Surface Electromyography Sensor

    PubMed Central

    Tang, Xueyan; Liu, Yunhui; Lv, Congyi; Sun, Dong

    2012-01-01

    The human hand has multiple degrees of freedom (DOF) for achieving high-dexterity motions. Identifying and replicating human hand motions are necessary to perform precise and delicate operations in many applications, such as haptic applications. Surface electromyography (sEMG) sensors are a low-cost method for identifying hand motions, in addition to the conventional methods that use data gloves and vision detection. The identification of multiple hand motions is challenging because the error rate typically increases significantly with the addition of more hand motions. Thus, the current study proposes two new methods for feature extraction to solve the problem above. The first method is the extraction of the energy ratio features in the time-domain, which are robust and invariant to motion forces and speeds for the same gesture. The second method is the extraction of the concordance correlation features that describe the relationship between every two channels of the multi-channel sEMG sensor system. The concordance correlation features of a multi-channel sEMG sensor system were shown to provide a vast amount of useful information for identification. Furthermore, a new cascaded-structure classifier is also proposed, in which 11 types of hand gestures can be identified accurately using the newly defined features. Experimental results show that the success rate for the identification of the 11 gestures is significantly high. PMID:22438703

  1. Hand motion classification using a multi-channel surface electromyography sensor.

    PubMed

    Tang, Xueyan; Liu, Yunhui; Lv, Congyi; Sun, Dong

    2012-01-01

    The human hand has multiple degrees of freedom (DOF) for achieving high-dexterity motions. Identifying and replicating human hand motions are necessary to perform precise and delicate operations in many applications, such as haptic applications. Surface electromyography (sEMG) sensors are a low-cost method for identifying hand motions, in addition to the conventional methods that use data gloves and vision detection. The identification of multiple hand motions is challenging because the error rate typically increases significantly with the addition of more hand motions. Thus, the current study proposes two new methods for feature extraction to solve the problem above. The first method is the extraction of the energy ratio features in the time-domain, which are robust and invariant to motion forces and speeds for the same gesture. The second method is the extraction of the concordance correlation features that describe the relationship between every two channels of the multi-channel sEMG sensor system. The concordance correlation features of a multi-channel sEMG sensor system were shown to provide a vast amount of useful information for identification. Furthermore, a new cascaded-structure classifier is also proposed, in which 11 types of hand gestures can be identified accurately using the newly defined features. Experimental results show that the success rate for the identification of the 11 gestures is significantly high.

  2. A Review of Classification Techniques of EMG Signals during Isotonic and Isometric Contractions

    PubMed Central

    Nazmi, Nurhazimah; Abdul Rahman, Mohd Azizi; Yamamoto, Shin-Ichiroh; Ahmad, Siti Anom; Zamzuri, Hairi; Mazlan, Saiful Amri

    2016-01-01

    In recent years, there has been major interest in the exposure to physical therapy during rehabilitation. Several publications have demonstrated its usefulness in clinical/medical and human machine interface (HMI) applications. An automated system will guide the user to perform the training during rehabilitation independently. Advances in engineering have extended electromyography (EMG) beyond the traditional diagnostic applications to also include applications in diverse areas such as movement analysis. This paper gives an overview of the numerous methods available to recognize motion patterns of EMG signals for both isotonic and isometric contractions. Various signal analysis methods are compared by illustrating their applicability in real-time settings. This paper will be of interest to researchers who would like to select the most appropriate methodology in classifying motion patterns, especially during different types of contractions. For feature extraction, the probability density function (PDF) of EMG signals will be the main interest of this study. Following that, a brief explanation of the different methods for pre-processing, feature extraction and classifying EMG signals will be compared in terms of their performance. The crux of this paper is to review the most recent developments and research studies related to the issues mentioned above. PMID:27548165

  3. Detection of compensatory balance responses using wearable electromyography sensors for fall-risk assessment.

    PubMed

    Nouredanesh, Mina; Kukreja, Sunil L; Tung, James

    2016-08-01

    Loss of balance is prevalent in older adults and populations with gait and balance impairments. The present paper aims to develop a method to automatically distinguish compensatory balance responses (CBRs) from normal gait, based on activity patterns of muscles involved in maintaining balance. In this study, subjects were perturbed by lateral pushes while walking and surface electromyography (sEMG) signals were recorded from four muscles in their right leg. To extract sEMG time domain features, several filtering characteristics and segmentation approaches are examined. The performance of three classification methods, i.e., k-nearest neighbor, support vector machines, and random forests, were investigated for accurate detection of CBRs. Our results show that features extracted in the 50-200Hz band, segmented using peak sEMG amplitudes, and a random forest classifier detected CBRs with an accuracy of 92.35%. Moreover, our results support the important role of biceps femoris and rectus femoris muscles in stabilization and consequently discerning CBRs. This study contributes towards the development of wearable sensor systems to accurately and reliably monitor gait and balance control behavior in at-home settings (unsupervised conditions), over long periods of time, towards personalized fall risk assessment tools.

  4. Accuracy of the surface electromyography RMS processing for the diagnosis of myogenous temporomandibular disorder.

    PubMed

    Berni, Kelly Cristina dos Santos; Dibai-Filho, Almir Vieira; Pires, Paulo Fernandes; Rodrigues-Bigaton, Delaine

    2015-08-01

    Due to the multifactor etiology of temporomandibular disorder (TMD), the precise diagnosis remains a matter of debate and validated diagnostic tools are needed. The aim was to determine the accuracy of surface electromyography (sEMG) activity, assessed in the amplitude domain by the root mean square (RMS), in the diagnosis of TMD. One hundred twenty-three volunteers were evaluated using the Research Diagnostic Criteria for Temporomandibular Disorders and distributed into two groups: women with myogenous TMD (n=80) and women without TMD (n=43). The volunteers were then submitted to sEMG evaluation of the anterior temporalis, masseter and suprahyoid muscles at rest and during maximum voluntary teeth clenching (MVC) on parafilm. The accuracy, sensitivity and specificity of the muscle activity were analyzed. Differences between groups were found in all muscles analyzed at rest as well as in the masseter and suprahyoid muscles during MVC on parafilm. Moderate accuracy (AUC: 0.74-0.84) of the RMS sEMG was found in all muscles regarding the diagnosis of TMD at rest and in the suprahyoid muscles during MVC on parafilm. Moreover, sensitivity ranging from 71.3% to 80% and specificity from 60.5% to 76.6%. In contrast, RMS sEMG did not exhibit acceptable degrees of accuracy in the other masticatory muscles during MVC on parafilm. It was concluded that the RMS sEMG is a complementary tool for clinical diagnosis of the myogenous TMD. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Utility of multi-channel surface electromyography in assessment of focal hand dystonia.

    PubMed

    Sivadasan, Ajith; Sanjay, M; Alexander, Mathew; Devasahayam, Suresh R; Srinivasa, Babu K

    2013-09-01

    Surface electromyography (SEMG) allows objective assessment and guides selection of appropriate treatment in focal hand dystonia (FHD). Sixteen-channel SEMG obtained during different phases of a writing task was used to study timing, activation patterns, and spread of muscle contractions in FHD compared with normal controls. Customized software was developed to acquire and analyze EMG signals. SEMG of FHD subjects (20) showed "early onset" during motor imagery, rapid proximal muscle recruitment, agonist-antagonist co-contraction involving proximal muscle groups, "delayed offset" after stopping writing, higher rectified mean amplitudes, and mirror activity in contralateral limb compared with controls (16). Muscle activation latencies were heterogenous in FHD. Anticipation, delayed relaxation, and mirror EMG activation were noted in FHD. A clear pattern of muscle activation cannot be ascertained. Multi-channel SEMG can aid in objective assessment of temporal-spatial distribution of activity and can refine targeted therapies like chemodenervation and biofeedback. Copyright © 2013 Wiley Periodicals, Inc.

  6. Effect of window length on performance of the elbow-joint angle prediction based on electromyography

    NASA Astrophysics Data System (ADS)

    Triwiyanto; Wahyunggoro, Oyas; Adi Nugroho, Hanung; Herianto

    2017-05-01

    The high performance of the elbow joint angle prediction is essential on the development of the devices based on electromyography (EMG) control. The performance of the prediction depends on the feature of extraction parameters such as window length. In this paper, we evaluated the effect of the window length on the performance of the elbow-joint angle prediction. The prediction algorithm consists of zero-crossing feature extraction and second order of Butterworth low pass filter. The feature was used to extract the EMG signal by varying window length. The EMG signal was collected from the biceps muscle while the elbow was moved in the flexion and extension motion. The subject performed the elbow motion by holding a 1-kg load and moved the elbow in different periods (12 seconds, 8 seconds and 6 seconds). The results indicated that the window length affected the performance of the prediction. The 250 window lengths yielded the best performance of the prediction algorithm of (mean±SD) root mean square error = 5.68%±1.53% and Person’s correlation = 0.99±0.0059.

  7. Facial reactions to violent and comedy films: Association with callous-unemotional traits and impulsive aggression.

    PubMed

    Fanti, Kostas A; Kyranides, Melina Nicole; Panayiotou, Georgia

    2017-02-01

    The current study adds to prior research by investigating specific (happiness, sadness, surprise, disgust, anger and fear) and general (corrugator and zygomatic muscle activity) facial reactions to violent and comedy films among individuals with varying levels of callous-unemotional (CU) traits and impulsive aggression (IA). Participants at differential risk of CU traits and IA were selected from a sample of 1225 young adults. In Experiment 1, participants (N = 82) facial expressions were recorded while they watched violent and comedy films. Video footage of participants' facial expressions was analysed using FaceReader, a facial coding software that classifies facial reactions. Findings suggested that individuals with elevated CU traits showed reduced facial reactions of sadness and disgust to violent films, indicating low empathic concern in response to victims' distress. In contrast, impulsive aggressors produced specifically more angry facial expressions when viewing violent and comedy films. In Experiment 2 (N = 86), facial reactions were measured by monitoring facial electromyography activity. FaceReader findings were verified by the reduced facial electromyography at the corrugator, but not the zygomatic, muscle in response to violent films shown by individuals high in CU traits. Additional analysis suggested that sympathy to victims explained the association between CU traits and reduced facial reactions to violent films.

  8. Non-invasive transabdominal uterine electromyography correlates with the strength of intrauterine pressure and is predictive of labor and delivery.

    PubMed

    Maul, H; Maner, W L; Olson, G; Saade, G R; Garfield, R E

    2004-05-01

    The study was conducted to investigate whether the strength of uterine contractions monitored invasively by intrauterine pressure catheter could be determined from transabdominal electromyography (EMG) and to estimate whether EMG is a better predictor of true labor compared to tocodynamometry (TOCO). Uterine EMG was recorded from the abdominal surface in laboring patients simultaneously monitored with an intrauterine pressure catheter (n = 13) or TOCO (n = 24). Three to five contractions per patient and corresponding electrical bursts were randomly selected and analyzed (integral of intrauterine pressure; integral, frequency, amplitude of contraction curve on TOCO; burst energy for EMG). The Mann-Whitney test, Spearman correlation and receiver operator characteristics (ROC) analysis were used as appropriate (significance was assumed at a value of p < 0.05). EMG correlated strongly with intrauterine pressure (r = 0.764; p = 0.002). EMG burst energy levels were significantly higher in patients who delivered within 48 h compared to those who delivered later (median [25%/75%]: 96,640 [26,520-322,240] vs. 2960 [1560-10,240]; p < 0.001), whereas none of the TOCO parameters were different. In addition, burst energy levels were highly predictive of delivery within 48 h (AUC = 0.9531; p < 0.0001). EMG measurements correlated strongly with the strength of contractions and therefore may be a valuable alternative to invasive measurement of intrauterine pressure. Unlike TOCO, transabdominal uterine EMG can be used reliably to predict labor and delivery.

  9. Surface EMG signals in very late-stage of Duchenne muscular dystrophy: a case study.

    PubMed

    Lobo-Prat, Joan; Janssen, Mariska M H P; Koopman, Bart F J M; Stienen, Arno H A; de Groot, Imelda J M

    2017-08-29

    Robotic arm supports aim at improving the quality of life for adults with Duchenne muscular dystrophy (DMD) by augmenting their residual functional abilities. A critical component of robotic arm supports is the control interface, as is it responsible for the human-machine interaction. Our previous studies showed the feasibility of using surface electromyography (sEMG) as a control interface to operate robotic arm supports in adults with DMD (22-24 years-old). However, in the biomedical engineering community there is an often raised skepticism on whether adults with DMD at the last stage of their disease have sEMG signals that can be measured and used for control. In this study sEMG signals from Biceps and Triceps Brachii muscles were measured for the first time in a 37 year-old man with DMD (Brooke 6) that lost his arm function 15 years ago. The sEMG signals were measured during maximal and sub-maximal voluntary isometric contractions and evaluated in terms of signal-to-noise ratio and co-activation ratio. Beyond the profound deterioration of the muscles, we found that sEMG signals from both Biceps and Triceps muscles were measurable in this individual, although with a maximum signal amplitude 100 times lower compared to sEMG from healthy subjects. The participant was able to voluntarily modulate the required level of muscle activation during the sub-maximal voluntary isometric contractions. Despite the low sEMG amplitude and a considerable level of muscle co-activation, simulations of an elbow orthosis using the measured sEMG as driving signal indicated that the sEMG signals of the participant had the potential to provide control of elbow movements. To the best of our knowledge this is the first time that sEMG signals from a man with DMD at the last-stage of the disease were measured, analyzed and reported. These findings offer promising perspectives to the use of sEMG as an intuitive and natural control interface for robotic arm supports in adults with DMD until

  10. Breath detection by transcutaneous electromyography of the diaphragm and the Graseby capsule in preterm infants.

    PubMed

    de Waal, Cornelia G; Kraaijenga, Juliette V; Hutten, Gerard J; de Jongh, Frans H; van Kaam, Anton H

    2017-12-01

    To compare triggering, breath detection and delay time of the Graseby capsule (GC) and transcutaneous electromyography of the diaphragm (dEMG) in spontaneous breathing preterm infants. In this observational study, a 30 minutes respiration measurement was conducted by respiratory inductance plethysmography (RIP), the GC, and dEMG in stable preterm infants. Triggering was investigated with an in vitro set-up using the Infant Flow ® SiPAP TM system. The possibility to optimize breath detection was tested by developing new algorithms with the abdominal RIP band (RIP AB ) as gold standard. In a subset of breaths, the delay time was calculated between the inspiratory onset in the RIP AB signal and in the GC and dEMG signal. Fifteen preterm infants with a mean gestational age of 28 ± 2 weeks and a mean birth weight of 1086 ± 317 g were included. In total, 14 773 breaths were analyzed. Based on the GC and dEMG signal, the Infant Flow ® SiPAP™ system, respectively, triggered 67.8% and 62.6% of the breaths. Breath detection was improved to 99.9% for the GC and 113.4% for dEMG in new algorithms. In 1492 stable breaths, the median delay time of inspiratory onset detection was +154 ms (IQR +118 to +164) in the GC and -50 ms (IQR -90 to -22) in the dEMG signal. Breath detection using the GC can be improved by optimizing the algorithm. Transcutaneous dEMG provides similar breath detection but with the advantage of detecting the onset of inspiration earlier than the GC. © 2017 Wiley Periodicals, Inc.

  11. Model for nerve visualization in preoperative image data based on intraoperatively gained EMG signals.

    PubMed

    Strauss, Mario; Lueders, Christian; Strauss, Gero; Stopp, Sebastian; Shi, Jiaxi; Lueth, Tim C

    2008-01-01

    While removing bone tissue of the mastoid, the facial nerve is at risk of being injured. In this contribution a model for nerve visualization in preoperative image data based on intraoperatively gained EMG signals is proposed. A neuro monitor can assist the surgeon locating and preserving the nerve. With the proposed model gained EMG signals can be spatially related to the patient resp. the image data. During navigation the detected nerve course will be visualized and hence permanently available for assessing the situs.

  12. Design, development and testing of a low-cost sEMG system and its use in recording muscle activity in human gait.

    PubMed

    Supuk, Tamara Grujic; Skelin, Ana Kuzmanic; Cic, Maja

    2014-05-07

    Surface electromyography (sEMG) is an important measurement technique used in biomechanical, rehabilitation and sport environments. In this article the design, development and testing of a low-cost wearable sEMG system are described. The hardware architecture consists of a two-cascade small-sized bioamplifier with a total gain of 2,000 and band-pass of 3 to 500 Hz. The sampling frequency of the system is 1,000 Hz. Since real measured EMG signals are usually corrupted by various types of noises (motion artifacts, white noise and electromagnetic noise present at 50 Hz and higher harmonics), we have tested several denoising techniques, both on artificial and measured EMG signals. Results showed that a wavelet-based technique implementing Daubechies5 wavelet and soft sqtwolog thresholding is the most appropriate for EMG signals denoising. To test the system performance, EMG activities of six dominant muscles of ten healthy subjects during gait were measured (gluteus maximus, biceps femoris, sartorius, rectus femoris, tibialis anterior and medial gastrocnemius). The obtained EMG envelopes presented against the duration of gait cycle were compared favourably with the EMG data available in the literature, suggesting that the proposed system is suitable for a wide range of applications in biomechanics.

  13. Design, Development and Testing of a Low-Cost sEMG System and Its Use in Recording Muscle Activity in Human Gait

    PubMed Central

    Supuk, Tamara Grujic; Skelin, Ana Kuzmanic; Cic, Maja

    2014-01-01

    Surface electromyography (sEMG) is an important measurement technique used in biomechanical, rehabilitation and sport environments. In this article the design, development and testing of a low-cost wearable sEMG system are described. The hardware architecture consists of a two-cascade small-sized bioamplifier with a total gain of 2,000 and band-pass of 3 to 500 Hz. The sampling frequency of the system is 1,000 Hz. Since real measured EMG signals are usually corrupted by various types of noises (motion artifacts, white noise and electromagnetic noise present at 50 Hz and higher harmonics), we have tested several denoising techniques, both on artificial and measured EMG signals. Results showed that a wavelet—based technique implementing Daubechies5 wavelet and soft sqtwolog thresholding is the most appropriate for EMG signals denoising. To test the system performance, EMG activities of six dominant muscles of ten healthy subjects during gait were measured (gluteus maximus, biceps femoris, sartorius, rectus femoris, tibialis anterior and medial gastrocnemius). The obtained EMG envelopes presented against the duration of gait cycle were compared favourably with the EMG data available in the literature, suggesting that the proposed system is suitable for a wide range of applications in biomechanics. PMID:24811078

  14. Onset in abdominal muscles recorded simultaneously by ultrasound imaging and intramuscular electromyography.

    PubMed

    Vasseljen, Ottar; Fladmark, Anne M; Westad, Christian; Torp, Hans G

    2009-04-01

    Delayed onset of muscle activity in abdominal muscles has been related to low back pain. To investigate this in larger clinical trials it would be beneficial if non-invasive and less cumbersome alternatives to intramuscular electromyography (EMG) were available. This study was designed to compare onset of muscle activity recorded by intramuscular EMG to onset of muscle deformations by ultrasound imaging. Muscle deformations were recorded by two ultrasound imaging modes at high time resolution (m-mode and tissue velocity) in separate sessions and compared to simultaneously recorded intramuscular EMG in three abdominal muscles. Tissue velocity imaging was converted to strain rate which measures deformation velocity gradients within small regions, giving information about the rate of local tissue shortening or lengthening along the beam axis. Onsets in transversus abdominis (TrA), obliquus internus abdominis (OI) and obliquus externus abdominis (OE) were recorded during rapid arm flexions in ten healthy subjects. During ultrasound m-mode recordings, the results showed that mean onsets by EMG were detected 7 ms (95% CI of mean difference; +/-4 ms) and 2 ms (95% CI of mean difference; +/-6 ms) before concurrent ultrasound m-mode detected onsets in TrA and OI, respectively. In contrast, OE onset was recorded 54 ms (95% CI of bias; +/-16 ms) later by EMG compared to ultrasound m-mode. The discrepancy of ultrasound m-mode to accurately record onset in OE was practically corrected in the ultrasound-based strain rate recordings. However, this could only be applied on half of the subjects due to the angle dependency between the ultrasound beam and the direction of the contraction in strain rate recordings. The angle dependency needs to be further explored.

  15. Comparison of six electromyography acquisition setups on hand movement classification tasks

    PubMed Central

    Pizzolato, Stefano; Tagliapietra, Luca; Cognolato, Matteo; Reggiani, Monica; Müller, Henning

    2017-01-01

    Hand prostheses controlled by surface electromyography are promising due to the non-invasive approach and the control capabilities offered by machine learning. Nevertheless, dexterous prostheses are still scarcely spread due to control difficulties, low robustness and often prohibitive costs. Several sEMG acquisition setups are now available, ranging in terms of costs between a few hundred and several thousand dollars. The objective of this paper is the relative comparison of six acquisition setups on an identical hand movement classification task, in order to help the researchers to choose the proper acquisition setup for their requirements. The acquisition setups are based on four different sEMG electrodes (including Otto Bock, Delsys Trigno, Cometa Wave + Dormo ECG and two Thalmic Myo armbands) and they were used to record more than 50 hand movements from intact subjects with a standardized acquisition protocol. The relative performance of the six sEMG acquisition setups is compared on 41 identical hand movements with a standardized feature extraction and data analysis pipeline aimed at performing hand movement classification. Comparable classification results are obtained with three acquisition setups including the Delsys Trigno, the Cometa Wave and the affordable setup composed of two Myo armbands. The results suggest that practical sEMG tests can be performed even when costs are relevant (e.g. in small laboratories, developing countries or use by children). All the presented datasets can be used for offline tests and their quality can easily be compared as the data sets are publicly available. PMID:29023548

  16. Classification of Anticipatory Signals for Grasp and Release from Surface Electromyography.

    PubMed

    Siu, Ho Chit; Shah, Julie A; Stirling, Leia A

    2016-10-25

    Surface electromyography (sEMG) is a technique for recording natural muscle activation signals, which can serve as control inputs for exoskeletons and prosthetic devices. Previous experiments have incorporated these signals using both classical and pattern-recognition control methods in order to actuate such devices. We used the results of an experiment incorporating grasp and release actions with object contact to develop an intent-recognition system based on Gaussian mixture models (GMM) and continuous-emission hidden Markov models (HMM) of sEMG data. We tested this system with data collected from 16 individuals using a forearm band with distributed sEMG sensors. The data contain trials with shifted band alignments to assess robustness to sensor placement. This study evaluated and found that pattern-recognition-based methods could classify transient anticipatory sEMG signals in the presence of shifted sensor placement and object contact. With the best-performing classifier, the effect of label lengths in the training data was also examined. A mean classification accuracy of 75.96% was achieved through a unigram HMM method with five mixture components. Classification accuracy on different sub-movements was found to be limited by the length of the shortest sub-movement, which means that shorter sub-movements within dynamic sequences require larger training sets to be classified correctly. This classification of user intent is a potential control mechanism for a dynamic grasping task involving user contact with external objects and noise. Further work is required to test its performance as part of an exoskeleton controller, which involves contact with actuated external surfaces.

  17. Classification of Anticipatory Signals for Grasp and Release from Surface Electromyography

    PubMed Central

    Siu, Ho Chit; Shah, Julie A.; Stirling, Leia A.

    2016-01-01

    Surface electromyography (sEMG) is a technique for recording natural muscle activation signals, which can serve as control inputs for exoskeletons and prosthetic devices. Previous experiments have incorporated these signals using both classical and pattern-recognition control methods in order to actuate such devices. We used the results of an experiment incorporating grasp and release actions with object contact to develop an intent-recognition system based on Gaussian mixture models (GMM) and continuous-emission hidden Markov models (HMM) of sEMG data. We tested this system with data collected from 16 individuals using a forearm band with distributed sEMG sensors. The data contain trials with shifted band alignments to assess robustness to sensor placement. This study evaluated and found that pattern-recognition-based methods could classify transient anticipatory sEMG signals in the presence of shifted sensor placement and object contact. With the best-performing classifier, the effect of label lengths in the training data was also examined. A mean classification accuracy of 75.96% was achieved through a unigram HMM method with five mixture components. Classification accuracy on different sub-movements was found to be limited by the length of the shortest sub-movement, which means that shorter sub-movements within dynamic sequences require larger training sets to be classified correctly. This classification of user intent is a potential control mechanism for a dynamic grasping task involving user contact with external objects and noise. Further work is required to test its performance as part of an exoskeleton controller, which involves contact with actuated external surfaces. PMID:27792155

  18. The face of pain--a pilot study to validate the measurement of facial pain expression with an improved electromyogram method.

    PubMed

    Wolf, Karsten; Raedler, Thomas; Henke, Kai; Kiefer, Falk; Mass, Reinhard; Quante, Markus; Wiedemann, Klaus

    2005-01-01

    The purpose of this pilot study was to establish the validity of an improved facial electromyogram (EMG) method for the measurement of facial pain expression. Darwin defined pain in connection with fear as a simultaneous occurrence of eye staring, brow contraction and teeth chattering. Prkachin was the first to use the video-based Facial Action Coding System to measure facial expressions while using four different types of pain triggers, identifying a group of facial muscles around the eyes. The activity of nine facial muscles in 10 healthy male subjects was analyzed. Pain was induced through a laser system with a randomized sequence of different intensities. Muscle activity was measured with a new, highly sensitive and selective facial EMG. The results indicate two groups of muscles as key for pain expression. These results are in concordance with Darwin's definition. As in Prkachin's findings, one muscle group is assembled around the orbicularis oculi muscle, initiating eye staring. The second group consists of the mentalis and depressor anguli oris muscles, which trigger mouth movements. The results demonstrate the validity of the facial EMG method for measuring facial pain expression. Further studies with psychometric measurements, a larger sample size and a female test group should be conducted.

  19. Electromyography of wrist and finger flexor muscles in olive baboons (Papio anubis).

    PubMed

    Patel, Biren A; Larson, Susan G; Stern, Jack T

    2012-01-01

    Some non-human primates use digitigrade hand postures when walking slowly on the ground. As a component of an extended limb, a digitigrade posture can help minimize wrist joint moments thereby requiring little force production directly from wrist flexors (and/or from the assistance of finger flexors) to maintain limb posture. As a consequence, less active muscle volume would be required from these anti-gravity muscles and overall metabolic costs associated with locomotion could be reduced. To investigate whether the use of digitigrade hand postures during walking in primates entails minimal use of anti-gravity muscles, this study examined electromyography (EMG) patterns in both the wrist and finger flexor muscles in facultatively digitigrade olive baboons (Papio anubis) across a range of speeds. The results demonstrate that baboons can adopt a digitigrade hand posture when standing and moving at slow speeds without requiring substantial EMG activity from distal anti-gravity muscles. Higher speed locomotion, however, entails increasing EMG activity and is accompanied by a dynamic shift to a more palmigrade-like limb posture. Thus, the ability to adopt a digitigrade hand posture by monkeys is an adaptation for ground living, but it was never co-opted for fast locomotion. Rather, digitigrady in primates appears to be related to energetic efficiency for walking long distances.

  20. A novel fuzzy approach for automatic Brunnstrom stage classification using surface electromyography.

    PubMed

    Liparulo, Luca; Zhang, Zhe; Panella, Massimo; Gu, Xudong; Fang, Qiang

    2017-08-01

    Clinical assessment plays a major role in post-stroke rehabilitation programs for evaluating impairment level and tracking recovery progress. Conventionally, this process is manually performed by clinicians using chart-based ordinal scales which can be both subjective and inefficient. In this paper, a novel approach based on fuzzy logic is proposed which automatically evaluates stroke patients' impairment level using single-channel surface electromyography (sEMG) signals and generates objective classification results based on the widely used Brunnstrom stages of recovery. The correlation between stroke-induced motor impairment and sEMG features on both time and frequency domain is investigated, and a specifically designed fuzzy kernel classifier based on geometrically unconstrained membership function is introduced in the study to tackle the challenges in discriminating data classes with complex separating surfaces. Experiments using sEMG data collected from stroke patients have been carried out to examine the validity and feasibility of the proposed method. In order to ensure the generalization capability of the classifier, a cross-validation test has been performed. The results, verified using the evaluation decisions provided by an expert panel, have reached a rate of success of the 92.47%. The proposed fuzzy classifier is also compared with other pattern recognition techniques to demonstrate its superior performance in this application.

  1. An inverse dynamics approach to face animation.

    PubMed

    Pitermann, M; Munhall, K G

    2001-09-01

    Muscle-based models of the human face produce high quality animation but rely on recorded muscle activity signals or synthetic muscle signals that are often derived by trial and error. This paper presents a dynamic inversion of a muscle-based model (Lucero and Munhall, 1999) that permits the animation to be created from kinematic recordings of facial movements. Using a nonlinear optimizer (Powell's algorithm), the inversion produces a muscle activity set for seven muscles in the lower face that minimize the root mean square error between kinematic data recorded with OPTOTRAK and the corresponding nodes of the modeled facial mesh. This inverted muscle activity is then used to animate the facial model. In three tests of the inversion, strong correlations were observed for kinematics produced from synthetic muscle activity, for OPTOTRAK kinematics recorded from a talker for whom the facial model is morphologically adapted and finally for another talker with the model morphology adapted to a different individual. The correspondence between the animation kinematics and the three-dimensional OPTOTRAK data are very good and the animation is of high quality. Because the kinematic to electromyography (EMG) inversion is ill posed, there is no relation between the actual EMG and the inverted EMG. The overall redundancy of the motor system means that many different EMG patterns can produce the same kinematic output.

  2. EMG-force relationship during static contraction: effects on sensor placement locations on biceps brachii muscle.

    PubMed

    Ahamed, Nizam Uddin; Sundaraj, Kenneth; Alqahtani, Mahdi; Altwijri, Omar; Ali, Md Asraf; Islam, Md Anamul

    2014-01-01

    The relationship between surface electromyography (EMG) and force have been the subject of ongoing investigations and remain a subject of controversy. Even under static conditions, the relationships at different sensor placement locations in the biceps brachii (BB) muscle are complex. The aim of this study was to compare the activity and relationship between surface EMG and static force from the BB muscle in terms of three sensor placement locations. Twenty-one right hand dominant male subjects (age 25.3±1.2 years) participated in the study. Surface EMG signals were detected from the subject's right BB muscle. The muscle activation during force was determined as the root mean square (RMS) electromyographic signal normalized to the peak RMS EMG signal of isometric contraction for 10 s. The statistical analysis included linear regression to examine the relationship between EMG amplitude and force of contraction [40-100% of maximal voluntary contraction (MVC)], repeated measures ANOVA to assess differences among the sensor placement locations, and coefficient of variation (CoV) for muscle activity variation. The results demonstrated that when the sensor was placed on the muscle belly, the linear slope coefficient was significantly greater for EMG versus force testing (r2=0.62, P<0.05) than when placed on the lower part (r2=0.31, P>0.05) and upper part of the muscle belly (r2=0.29, P<0.05). In addition, the EMG signal activity on the muscle belly had less variability than the upper and lower parts (8.55% vs. 15.12% and 12.86%, respectively). These findings indicate the importance of applying the surface EMG sensor at the appropriate locations that follow muscle fiber orientation of the BB muscle during static contraction. As a result, EMG signals of three different placements may help to understand the difference in the amplitude of the signals due to placement.

  3. Muscle fatigue evaluation of astronaut upper limb based on sEMG and subjective assessment

    NASA Astrophysics Data System (ADS)

    Zu, Xiaoqi; Zhou, Qianxiang; Li, Yun

    2012-07-01

    All movements are driven by muscle contraction, and it is easy to cause muscle fatigue. Evaluation of muscle fatigue is a hot topic in the area of astronaut life support training and rehabilitation. If muscle gets into fatigue condition, it may reduce work efficiency and has an impact on psychological performance. Therefore it is necessary to develop an accurate and usable method on muscle fatigue evaluation of astronaut upper limb. In this study, we developed a method based on surface electromyography (sEMG) and subjective assessment (Borg scale) to evaluate local muscle fatigue. Fifteen healthy young male subjects participated in the experiment. They performed isometric muscle contractions of the upper limb. sEMG of the biceps brachii were recorded during the entire process of isotonic muscle contraction and Borg scales of muscle fatigue were collected in certain times. sEMG were divided into several parts, and then mean energy of each parts were calculated by the one-twelfth band octave method. Equations were derived based on the relationship between the mean energy of sEMG and Borg scale. The results showed that cubic curve could describe the degree of local muscle fatigue, and could be used to evaluate and monitor local muscle fatigue during the entire process.

  4. Altered EMG patterns in diabetic neuropathic and not neuropathic patients during step ascending and descending.

    PubMed

    Spolaor, Fabiola; Sawacha, Zimi; Guarneri, Gabriella; Del Din, Silvia; Avogaro, Angelo; Cobelli, Claudio

    2016-12-01

    Diabetic peripheral neuropathy (DPN) causes motor control alterations during daily life activities. Tripping during walking or stair climbing is the predominant cause of falls in the elderly subjects with DPN and without (NoDPN). Surface Electromyography (sEMG) has been shown to be a valid tool for detecting alterations of motor functions in subjects with DPN. This study aims at investigating the presence of functional alterations in diabetic subjects during stair climbing and at exploring the relationship between altered muscle activation and temporal parameter. Lower limb muscle activities, temporal parameters and speed were evaluated in 50 subjects (10 controls, 20 with DPN, 20 without DPN), while climbing up and down a stair, using sEMG, three-dimentional motion capture and force plates. Magnitude and timing of sEMG linear envelopes peaks were extracted. Level walking was used as reference condition for the comparison with step negotiation. sEMG, speed and temporal parameters revealed significant differences among all groups of patients. Results showed an association between earlier activation of lower limb muscles and reduced speed in subjects with DPN. Speed and temporal parameters significantly correlated with sEMG (p<0.05). The findings of this study are encouraging and could be used to improve rehabilitation programs aiming at reducing falls risk in diabetic subjects. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Preliminary Study on Continuous Recognition of Elbow Flexion/Extension Using sEMG Signals for Bilateral Rehabilitation

    PubMed Central

    Song, Zhibin; Zhang, Songyuan

    2016-01-01

    Surface electromyography (sEMG) signals are closely related to the activation of human muscles and the motion of the human body, which can be used to estimate the dynamics of human limbs in the rehabilitation field. They also have the potential to be used in the application of bilateral rehabilitation, where hemiplegic patients can train their affected limbs following the motion of unaffected limbs via some rehabilitation devices. Traditional methods to process the sEMG focused on motion pattern recognition, namely, discrete patterns, which are not satisfactory for use in bilateral rehabilitation. In order to overcome this problem, in this paper, we built a relationship between sEMG signals and human motion in elbow flexion and extension on the sagittal plane. During the conducted experiments, four participants were required to perform elbow flexion and extension on the sagittal plane smoothly with only an inertia sensor in their hands, where forearm dynamics were not considered. In these circumstances, sEMG signals were weak compared to those with heavy loads or high acceleration. The contrastive experimental results show that continuous motion can also be obtained within an acceptable precision range. PMID:27775573

  6. Preliminary Study on Continuous Recognition of Elbow Flexion/Extension Using sEMG Signals for Bilateral Rehabilitation.

    PubMed

    Song, Zhibin; Zhang, Songyuan

    2016-10-19

    Surface electromyography (sEMG) signals are closely related to the activation of human muscles and the motion of the human body, which can be used to estimate the dynamics of human limbs in the rehabilitation field. They also have the potential to be used in the application of bilateral rehabilitation, where hemiplegic patients can train their affected limbs following the motion of unaffected limbs via some rehabilitation devices. Traditional methods to process the sEMG focused on motion pattern recognition, namely, discrete patterns, which are not satisfactory for use in bilateral rehabilitation. In order to overcome this problem, in this paper, we built a relationship between sEMG signals and human motion in elbow flexion and extension on the sagittal plane. During the conducted experiments, four participants were required to perform elbow flexion and extension on the sagittal plane smoothly with only an inertia sensor in their hands, where forearm dynamics were not considered. In these circumstances, sEMG signals were weak compared to those with heavy loads or high acceleration. The contrastive experimental results show that continuous motion can also be obtained within an acceptable precision range.

  7. When Early Experiences Build a Wall to Others’ Emotions: An Electrophysiological and Autonomic Study

    PubMed Central

    Ardizzi, Martina; Martini, Francesca; Umiltà, Maria Alessandra; Sestito, Mariateresa; Ravera, Roberto; Gallese, Vittorio

    2013-01-01

    Facial expression of emotions is a powerful vehicle for communicating information about others’ emotional states and it normally induces facial mimicry in the observers. The aim of this study was to investigate if early aversive experiences could interfere with emotion recognition, facial mimicry, and with the autonomic regulation of social behaviors. We conducted a facial emotion recognition task in a group of “street-boys” and in an age-matched control group. We recorded facial electromyography (EMG), a marker of facial mimicry, and respiratory sinus arrhythmia (RSA), an index of the recruitment of autonomic system promoting social behaviors and predisposition, in response to the observation of facial expressions of emotions. Results showed an over-attribution of anger, and reduced EMG responses during the observation of both positive and negative expressions only among street-boys. Street-boys also showed lower RSA after observation of facial expressions and ineffective RSA suppression during presentation of non-threatening expressions. Our findings suggest that early aversive experiences alter not only emotion recognition but also facial mimicry of emotions. These deficits affect the autonomic regulation of social behaviors inducing lower social predisposition after the visualization of facial expressions and an ineffective recruitment of defensive behavior in response to non-threatening expressions. PMID:23593374

  8. [Data collection of signals in the multi-channel sEMG system of masticatory muscles and development and preliminary clinical application of an analytic system].

    PubMed

    Du, Hongliang; Li, Xin; Li, Shan; Zhang, Rui; Song, Rong; Li, Lan; Wang, Wei; Kang, Hong

    2014-02-01

    The aim of this study was to design a simple, economic, with high Common Mode Rejection Ratio (CMRR), preamplifier and multi-channel masticatory muscle surface electromyography (sEMG) signal acquisition system assisting to diagnose temporomandibular disorders (TMD). We used the USB interface technology in the EMG data with the aid of the windows to operate system and graphical interface. Eight patients with TMD and eight controls were analyzed separately using this system. In this system, we analyzed sEMG by an optional combination of time domain, frequency domain, time-frequency, several spectral analysis, wavelets and other special algorithms under multi-parameter. Multi-channel sEMG System of Masticatory Muscles is a simple, economic system. It has high sensitivity and specificity. The sEMG signals were changed in patients with TMD. The system would pave the way for diagnosis TMD and help us to assess the treatment effect. A novel and objective method is provided for diagnosis and treatment of oral-maxillofacial disease and functional reconstruction.

  9. Dental Implants – Perceiving Patients’ Satisfaction in Relation to Clinical and Electromyography Study on Implant Patients

    PubMed Central

    Saha, Soumendra

    2015-01-01

    The aim of this study is to evaluate the satisfaction of patients with posterior implants in relation to the clinical success criteria and surface electromyography (sEMG) findings of the masseter and temporalis muscles. Total 42 subjects were investigated. Twenty one subjects with posterior dental implants were interviewed using a questionnaire and the clinical success criteria were determined based on The International Congress of Oral Implantologists. The myofunction of the masticatory muscles were assessed using sEMG (21 subjects) and compared to the control group of subjects without implants (21 subjects). Out of 21 subjects, all were satisfied with the aesthetics of their implant. Twenty of them (95.2%) were satisfied with its function and stability. As for clinical criteria, 100% (50) of the implants were successful with no pain, mobility or exudates. sEMG findings showed that patients have significantly lower (p<0.01) basal or resting median power frequency but with muscle burst. During chewing, control subjects showed faster chewing action. There was no difference in reaction and recovery time of clenching for both groups. In conclusion, the satisfaction of implant patients was high, and which was in relation to the successful clinical success criteria and sEMG findings. PMID:26465146

  10. Empathy, Einfühlung, and aesthetic experience: the effect of emotion contagion on appreciation of representational and abstract art using fEMG and SCR.

    PubMed

    Gernot, Gerger; Pelowski, Matthew; Leder, Helmut

    2017-03-17

    Since the advent of the concept of empathy in the scientific literature, it has been hypothesized, although not necessarily empirically verified, that empathic processes are essential to aesthetic experiences of visual art. We tested how the ability to "feel into" ("Einfühlung") emotional content-a central aspect of art empathy theories-affects the bodily responses to and the subjective judgments of representational and abstract paintings. The ability to feel into was measured by a standardized pre-survey on "emotional contagion"-the ability to pick up and mirror, or in short to "feel into", emotions, which often overlaps with higher general or interpersonal empathetic abilities. Participants evaluated the artworks on several aesthetic dimensions (liking, valence, moving, and interest), while their bodily reactions indicative of empathetic engagement (facial electromyography-EMG, and skin conductance responses-SCR) were recorded. High compared to low emotion contagion participants showed both more congruent and more intense bodily reactions (EMG and SCR) and aesthetic evaluations (higher being moved, valence, and interest) and also liked the art more. This was largely the case for both representational and abstract art, although stronger with the representational category. Our findings provide tentative evidence for recent arguments by art theorists for a close "empathic" mirroring of emotional content. We discuss this interpretation, as well as a potential tie between emotion contagion and a general increase in emotion intensity, both of which may impact, in tandem, the experience and evaluation of art.

  11. Electromyography and Mechanomyography Signals During Swallowing in Healthy Adults and Head and Neck Cancer Survivors.

    PubMed

    Constantinescu, Gabriela; Hodgetts, William; Scott, Dylan; Kuffel, Kristina; King, Ben; Brodt, Chris; Rieger, Jana

    2017-02-01

    Surface electromyography (sEMG) is used as an adjuvant to dysphagia therapy to demonstrate the activity of submental muscles during swallowing exercises. Mechanomyography (MMG) has been suggested as a potential superior alternative to sEMG; however, this advantage is not confirmed for signal acquired from submental muscles. This study compared the signal-to-noise ratio (SNR) obtained from sEMG and MMG sensors during swallowing tasks, in healthy participants and those with a history of head and neck cancer (HNC), a population with altered anatomy and a high incidence of dysphagia. Twenty-two healthy adults and 10 adults with a history of HNC participated in this study. sEMG and MMG signals were acquired during dry, thin liquid, effortful, and Mendelsohn maneuver swallows. SNR was compared between the two sensors using repeated measures ANOVAs and subsequent planned pairwise comparisons. Test-retest measures were collected on 20 % of participants. In healthy participants, MMG SNR was higher than that of sEMG for dry [t(21) = -3.02, p = 0.007] and thin liquid swallows [t(21) = -4.24, p < 0.001]. Although a significant difference for sensor was found in HNC participants F(1,9) = 5.54, p = 0.043, planned pairwise comparisons by task revealed no statistically significant difference between the two sensors. sEMG also showed much better test-retest reliability than MMG. Biofeedback provided as an adjuvant to dysphagia therapy in patients with HNC should employ sEMG technology, as this sensor type yielded better SNR and overall test-retest reliability. Poor MMG test-retest reliability was noted in both healthy and HNC participants and may have been related to differences in sensor application.

  12. An Embedded, Eight Channel, Noise Canceling, Wireless, Wearable sEMG Data Acquisition System With Adaptive Muscle Contraction Detection.

    PubMed

    Ergeneci, Mert; Gokcesu, Kaan; Ertan, Erhan; Kosmas, Panagiotis

    2018-02-01

    Wearable technology has gained increasing popularity in the applications of healthcare, sports science, and biomedical engineering in recent years. Because of its convenient nature, the wearable technology is particularly useful in the acquisition of the physiological signals. Specifically, the (surface electromyography) sEMG systems, which measure the muscle activation potentials, greatly benefit from this technology in both clinical and industrial applications. However, the current wearable sEMG systems have several drawbacks including inefficient noise cancellation, insufficient measurement quality, and difficult integration to customized applications. Additionally, none of these sEMG data acquisition systems can detect sEMG signals (i.e., contractions), which provides a valuable environment for further studies such as human machine interaction, gesture recognition, and fatigue tracking. To this end, we introduce an embedded, eight channel, noise canceling, wireless, wearable sEMG data acquisition system with adaptive muscle contraction detection. Our design consists of two stages, which are the sEMG sensors and the multichannel data acquisition unit. For the first stage, we propose a low cost, dry, and active sEMG sensor that captures the muscle activation potentials, a data acquisition unit that evaluates these captured multichannel sEMG signals and transmits them to a user interface. In the data acquisition unit, the sEMG signals are processed through embedded, adaptive methods in order to reject the power line noise and detect the muscle contractions. Through extensive experiments, we demonstrate that our sEMG sensor outperforms a widely used commercially available product and our data acquisition system achieves 4.583 dB SNR gain with accuracy in the detection of the contractions.

  13. Measuring facial expression of emotion.

    PubMed

    Wolf, Karsten

    2015-12-01

    Research into emotions has increased in recent decades, especially on the subject of recognition of emotions. However, studies of the facial expressions of emotion were compromised by technical problems with visible video analysis and electromyography in experimental settings. These have only recently been overcome. There have been new developments in the field of automated computerized facial recognition; allowing real-time identification of facial expression in social environments. This review addresses three approaches to measuring facial expression of emotion and describes their specific contributions to understanding emotion in the healthy population and in persons with mental illness. Despite recent progress, studies on human emotions have been hindered by the lack of consensus on an emotion theory suited to examining the dynamic aspects of emotion and its expression. Studying expression of emotion in patients with mental health conditions for diagnostic and therapeutic purposes will profit from theoretical and methodological progress.

  14. Electromyography in the four competitive swimming strokes: a systematic review.

    PubMed

    Martens, Jonas; Figueiredo, Pedro; Daly, Daniel

    2015-04-01

    The aim of this paper is to give an overview on 50 years of research in electromyography in the four competitive swimming strokes (crawl, breaststroke, butterfly, and backstroke). A systematic search of the existing literature was conducted using the combined keywords "swimming" and "EMG" on studies published before August 2013, in the electronic databases PubMed, ISI Web of Knowledge, SPORT discus, Academic Search Elite, Embase, CINAHL and Cochrane Library. The quality of each publication was assessed by two independent reviewers using a custom made checklist. Frequency of topics, muscles studied, swimming activities, populations, types of equipment and data treatment were determined from all selected papers and, when possible, results were compared and contrasted. In the first 20 years of EMG studies in swimming, most papers were published as congress proceedings. The methodological quality was low. Crawl stroke was most often studied. There was no standardized manner of defining swimming phases, normalizing the data or of presenting the results. Furthermore, the variability around the mean muscle activation patterns is large which makes it difficult to define a single pattern applicable to all swimmers in any activity examined. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Vitamin D, surface electromyography and physical function in uraemic patients.

    PubMed

    Heaf, J G; Molsted, S; Harrison, A P; Eiken, P; Prescott, L; Eidemak, I

    2010-01-01

    Muscle function is impaired in uraemic patients and several causes have been proposed. Deficiency of 25-hydroxyvitamin D (25-OHD), which affects muscle function in non-uraemic patients, may very well also be associated with the myopathy found in these patients. The aim of this study was to investigate the association between 25-OHD and muscle function as well as physical function in chronic kidney disease (CKD) and peritoneal dialysis (PD) patients. In this cross-sectional study, 21 adult patients with CKD stage 3-5 and 21 patients treated with PD were included. Standard biochemistry parameters were measured including 25-OHD, 1,25-dihydroxycholecalciferol (1,25-OHD) and parathyroid hormone analysis. Muscle function was determined by 30-second surface electromyography (sEMG) recordings of a right thigh muscle (vastus lateralis) and a second left finger muscle (second dorsal interosseous) under voluntary contractions. Physical function was determined using a 30-second Chair Stand Test and the Short Form 36 quality of life questionnaire. Clinical characteristics were collected from the patient records. Moderate vitamin 25-OHD deficiency (<40 nmol/l) was measured in 52% of patients with CKD and in 71% of the patients on PD. Severe deficiency (<15 nmol/l) was measured in 14% of patients on PD. There were no significant differences between the CKD and PD patients in terms of sEMG results. 25-OHD was not correlated to any results from the tests of sEMG or physical function. However, a higher sEMG frequency and signal root mean square (RMS) were positively associated with a higher Chair Stand Test score. Time to maximum sEMG frequency was negatively correlated to the Chair Stand Test score (p < 0.05), and positively correlated to the level of comorbidity (p < 0.05). sEMG signal peak-peak amplitude, frequency and RMS were positively correlated to the quality of life scales Physical Function, Role Physical, General Health, Vitality, Social Function, Mental Health, and

  16. EMGD-FE: an open source graphical user interface for estimating isometric muscle forces in the lower limb using an EMG-driven model.

    PubMed

    Menegaldo, Luciano Luporini; de Oliveira, Liliam Fernandes; Minato, Kin K

    2014-04-04

    This paper describes the "EMG Driven Force Estimator (EMGD-FE)", a Matlab® graphical user interface (GUI) application that estimates skeletal muscle forces from electromyography (EMG) signals. Muscle forces are obtained by numerically integrating a system of ordinary differential equations (ODEs) that simulates Hill-type muscle dynamics and that utilises EMG signals as input. In the current version, the GUI can estimate the forces of lower limb muscles executing isometric contractions. Muscles from other parts of the body can be tested as well, although no default values for model parameters are provided. To achieve accurate evaluations, EMG collection is performed simultaneously with torque measurement from a dynamometer. The computer application guides the user, step-by-step, to pre-process the raw EMG signals, create inputs for the muscle model, numerically integrate the ODEs and analyse the results. An example of the application's functions is presented using the quadriceps femoris muscle. Individual muscle force estimations for the four components as well the knee isometric torque are shown. The proposed GUI can estimate individual muscle forces from EMG signals of skeletal muscles. The estimation accuracy depends on several factors, including signal collection and modelling hypothesis issues.

  17. An internet-based wearable watch-over system for elderly and disabled utilizing EMG and accelerometer.

    PubMed

    Kishimoto, M; Yoshida, T; Hayasaka, T; Mori, D; Imai, Y; Matsuki, N; Ishikawa, T; Yamaguchi, T

    2009-01-01

    An effective way for preventing injuries and diseases among the elderly is to monitor their daily lives. In this regard, we propose the use of a "Hyper Hospital Network", which is an information support system for elderly people and patients. In the current study, we developed a wearable system for monitoring electromyography (EMG) and acceleration using the Hyper Hospital Network plan. The current system is an upgraded version of our previous system for gait analysis (Yoshida et al. [13], Telemedicine and e-Health 13 703-714), and lets us monitor decreases in exercise and the presence of a hemiplegic gait more accurately. To clarify the capabilities and reliability of the system, we performed three experimental evaluations: one to verify the performance of the wearable system, a second to detect a hemiplegic gait, and a third to monitor EMG and accelerations simultaneously. Our system successfully detected a lack of exercise by monitoring the iEMG in healthy volunteers. Moreover, by using EMG and acceleration signals simultaneously, the reliability of the Hampering Index (HI) for detecting hemiplegia walking was improved significantly. The present study provides useful knowledge for the development of a wearable computer designed to monitor the physical conditions of older persons and patients.

  18. Fasciculations in nerve and muscle disorders - A prospective study of muscle ultrasound compared to electromyography.

    PubMed

    Johansson, M T; Ellegaard, H R; Tankisi, H; Fuglsang-Frederiksen, A; Qerama, E

    2017-11-01

    We examined the clinical utility of muscle ultrasound (MUS) in detecting fasciculations in patients with nerve and muscle disorders (NMD) and investigated the impact on diagnostic sensitivity when combining electromyography (EMG) and MUS. We included 58 consecutive patients suspected to have NMD and 38 healthy subjects (HS). Patients and HS underwent MUS in 14 skeletal and two bulbar muscles and the video recordings of the MUS were anonymised. Only patients underwent EMG. The follow-up diagnoses were: 15 Amyotrophic lateral sclerosis (ALS), 15 polyneuropathy, 14 patients had other diagnoses (disease-control group) and 14 patients had no pathological findings. MUS detected more muscles with fasciculations among ALS patients compared to all other groups. In ALS patients, the dominating pattern of fasciculations was continuous (45%). More proximal muscles showed fasciculations among ALS patients compared to all other patient groups. MUS was more sensitive than EMG in detecting fasciculations (58% vs. 48%). When combining the two methods, the sensitivity in detecting fasciculations increased to 65%. Fasciculations in nine muscles could predict the ALS diagnosis with high sensitivity and specificity. MUS is a sensitive tool in detecting fasciculations in patients with NMD and performs well compared to EMG in diagnosing ALS. MUS may add valuable information in the clinic, especially in diagnosing ALS. Copyright © 2017 International Federation of Clinical Neurophysiology. Published by Elsevier B.V. All rights reserved.

  19. Safety of needle electromyography of the diaphragm: Anterior lung margins in quietly breathing healthy subjects.

    PubMed

    Podnar, Simon; Doorduin, Jonne

    2016-06-01

    Controversy persists as to whether the lung interposes on the needle electrode insertion path during diaphragm electromyography (EMG). Using high-resolution ultrasonography, we measured the distances between the medial recess of the intercostal spaces (ICSs) around the mid-clavicular line (MCL) and the lung margin. We performed measurements bilaterally during quiet breathing in the seated and supine positions. We studied 10 young healthy men and found that, in the first ICS with the medial recess clearly (i.e., several cm) lateral to MCL (usually the eighth ICS), the distance between the recommended insertion site and the lung margin varied from 7.5 to 17 cm. The distance was slightly larger on the right side and in the supine position. This study confirms that properly conducted "trans-intercostal" needle EMG of the diaphragm is generally safe in healthy subjects. Muscle Nerve 54: 54-57, 2016. © 2015 Wiley Periodicals, Inc.

  20. Inter-individual variability in the patterns of responses for electromyography and mechanomyography during cycle ergometry using an RPE-clamp model.

    PubMed

    Cochrane-Snyman, Kristen C; Housh, Terry J; Smith, Cory M; Hill, Ethan C; Jenkins, Nathaniel D M; Schmidt, Richard J; Johnson, Glen O

    2016-09-01

    To examine inter-individual variability versus composite models for the patterns of responses for electromyography (EMG) and mechanomyography (MMG) versus time relationships during moderate and heavy cycle ergometry using a rating of perceived exertion (RPE) clamp model. EMG amplitude (amplitude root-mean-square, RMS), EMG mean power frequency (MPF), MMG-RMS, and MMG-MPF were collected during two, 60-min rides at a moderate (RPE at the gas exchange threshold; RPEGET) and heavy (RPE at 15 % above the GET; RPEGET+15 %) intensity when RPE was held constant (clamped). Composite (mean) and individual responses for EMG and MMG parameters were compared during each 60-min ride. There was great inter-individual variability for each EMG and MMG parameters at RPEGET and RPEGET+15 %. Composite models showed decreases in EMG-RMS (r (2) = -0.92 and R (2) = 0.96), increases in EMG-MPF (R (2) = 0.90), increases in MMG-RMS (r (2) = 0.81 and 0.55), and either no change or a decrease (r (2) = 0.34) in MMG-MPF at RPEGET and RPEGET+15 %, respectively. The results of the present study indicated that there were differences between composite and individual patterns of responses for EMG and MMG parameters during moderate and heavy cycle ergometry at a constant RPE. Thus, composite models did not represent the unique muscle activation strategies exhibited by individual responses when cycling in the moderate and heavy intensity domains when using an RPE-clamp model.

  1. Electromyography and vaginal pressure of the pelvic floor muscles in women with recurrent vulvovaginal candidiasis and vulvodynia.

    PubMed

    Polpeta, Nádia Cristina; Giraldo, Paulo César; Juliato, Cássia Raquel Teatin; Yoshida, Laura Pagotto; do Amaral, Rose Luce Gomes; Eleutério, José

    2012-01-01

    To evaluate the electrical potentials and pressure exerted by the pelvic floor muscles in women with recurrent vulvovaginal candidiasis (RVVC) or vulvodynia as compared to control women. A cross-sectional study performed in the Female Outpatient Clinic of Genital Infections in the Department of Obstetrics and Gynecology of the Universidade Estadual de Campinas analyzed and compared electromyography (EMG) and vaginal pressure of the pelvic floor muscles in 61 women. Of these 61 women, 19 had vulvodynia, 12 had RVVC and 30 women had no disorder (control group). For data collection, the instrument used was the Miotool Uro device and its software Biotrainer (Miotec Ltd., Porto Alegre, Rio Grande do Sul, Brazil). The EMG evaluation of the pelvic floor muscles showed significantly lower values in the vulvodynia group (tonic contractions) and RVVC group (phasic and tonic contractions) when compared to the control group. No significant differences in basal tone EMG and vaginal pressure values at rest or during pelvic floor muscle contractions were found among groups. The maximum time of sustained contraction in patients with RVVC or vulvodynia was significantly lower (p < 0.0001) than in controls. Women with vulvodynia and RVVC have more frequent pelvic floor muscle dysfunction than controls when observed by EMG evaluation.

  2. Vastus lateralis surface and single motor unit EMG following submaximal shortening and lengthening contractions.

    PubMed

    Altenburg, Teatske M; de Ruiter, Cornelis J; Verdijk, Peter W L; van Mechelen, Willem; de Haan, Arnold

    2008-12-01

    A single shortening contraction reduces the force capacity of muscle fibers, whereas force capacity is enhanced following lengthening. However, how motor unit recruitment and discharge rate (muscle activation) are adapted to such changes in force capacity during submaximal contractions remains unknown. Additionally, there is limited evidence for force enhancement in larger muscles. We therefore investigated lengthening- and shortening-induced changes in activation of the knee extensors. We hypothesized that when the same submaximal torque had to be generated following shortening, muscle activation had to be increased, whereas a lower activation would suffice to produce the same torque following lengthening. Muscle activation following shortening and lengthening (20 degrees at 10 degrees /s) was determined using rectified surface electromyography (rsEMG) in a 1st session (at 10% and 50% maximal voluntary contraction (MVC)) and additionally with EMG of 42 vastus lateralis motor units recorded in a 2nd session (at 4%-47%MVC). rsEMG and motor unit discharge rates following shortening and lengthening were normalized to isometric reference contractions. As expected, normalized rsEMG (1.15 +/- 0.19) and discharge rate (1.11 +/- 0.09) were higher following shortening (p < 0.05). Following lengthening, normalized rsEMG (0.91 +/- 0.10) was, as expected, lower than 1.0 (p < 0.05), but normalized discharge rate (0.99 +/- 0.08) was not (p > 0.05). Thus, muscle activation was increased to compensate for a reduced force capacity following shortening by increasing the discharge rate of the active motor units (rate coding). In contrast, following lengthening, rsEMG decreased while the discharge rates of active motor units remained similar, suggesting that derecruitment of units might have occurred.

  3. Monitoring of recurrent and superior laryngeal nerve function using an Airwayscope™ during thyroid surgery.

    PubMed

    Ijichi, Kei; Sasano, Hiroshi; Harima, Megumi; Murakami, Shingo

    2017-10-01

    In thyroid surgery, intraoperative identification and preservation of the recurrent laryngeal nerve (RLN) and superior laryngeal nerve external branch (SLNEB) are crucial. Several reports have proposed that electromyography (EMG) monitoring is an acceptable adjunct for identification and preservation of the RLN. However, a limited number of hospitals have access to an EMG monitoring system. Therefore, the development of another viable monitoring method is required. The aim of the present study was to design a new RLN and SLNEB monitoring method combining an Airwayscope™ (AWS) and a facial nerve stimulator. The facial nerve-stimulating electrode stimulates the RLN or SLNEB, so that the movement of the vocal cord may be observed with an AWS. This monitoring method was performed on 10 patients with a thyroid tumor. In all the cases, RLN and SLNEB were identified and vocal cord function was preserved. All the patients exhibited normal vocal cord function following surgery. Thus, the new RLN and SLNEB monitoring method using an AWS and a facial nerve stimulator is useful in thyroid surgery, and this method may be used as a reliable and available alternative to EMG monitoring to ensure the normal function of the vocal cord.

  4. Entropy measures of back muscles EMG for subjects with and without pain

    NASA Astrophysics Data System (ADS)

    Zurcher, Ulrich; Kaufman, Miron; Vyhnalek, Bryan; Sung, Paul

    2007-10-01

    We have previously reported that the time-dependent entropy S(t) calculated from electromyography time series of low back muscles exhibit plateau-like behavior for intermediate times [50 ,ms < t < 0.5 ,s]. We proposed that the plateau value can be used to characterize the sEMG signal of subjects with low back pain [J. Rehab. Res. Dev. 44, 599 (2007)]. We report results of a larger study, and compare the entropies for the left -and right thoracic and left- and right lumbar muscles. We also compare entropies from muscles before and after physical therapy intervention.

  5. Supplementing biomechanical modeling with EMG analysis

    NASA Technical Reports Server (NTRS)

    Lewandowski, Beth; Jagodnik, Kathleen; Crentsil, Lawton; Humphreys, Bradley; Funk, Justin; Gallo, Christopher; Thompson, William; DeWitt, John; Perusek, Gail

    2016-01-01

    It is well established that astronauts experience musculoskeletal deconditioning when exposed to microgravity environments for long periods of time. Spaceflight exercise is used to counteract these effects, and the Advanced Resistive Exercise Device (ARED) on the International Space Station (ISS) has been effective in minimizing musculoskeletal losses. However, the exercise devices of the new exploration vehicles will have requirements of limited mass, power and volume. Because of these limitations, there is a concern that the exercise devices will not be as effective as ARED in maintaining astronaut performance. Therefore, biomechanical modeling is being performed to provide insight on whether the small Multi-Purpose Crew Vehicle (MPCV) device, which utilizes a single-strap design, will provide sufficient physiological loading to maintain musculoskeletal performance. Electromyography (EMG) data are used to supplement the biomechanical model results and to explore differences in muscle activation patterns during exercises using different loading configurations.

  6. Evaluation of jaw and neck muscle activities while chewing using EMG-EMG transfer function and EMG-EMG coherence function analyses in healthy subjects.

    PubMed

    Ishii, Tomohiro; Narita, Noriyuki; Endo, Hiroshi

    2016-06-01

    This study aims to quantitatively clarify the physiological features in rhythmically coordinated jaw and neck muscle EMG activities while chewing gum using EMG-EMG transfer function and EMG-EMG coherence function analyses in 20 healthy subjects. The chewing side masseter muscle EMG signal was used as the reference signal, while the other jaw (non-chewing side masseter muscle, bilateral anterior temporal muscles, and bilateral anterior digastric muscles) and neck muscle (bilateral sternocleidomastoid muscles) EMG signals were used as the examined signals in EMG-EMG transfer function and EMG-EMG coherence function analyses. Chewing-related jaw and neck muscle activities were aggregated in the first peak of the power spectrum in rhythmic chewing. The gain in the peak frequency represented the power relationships between jaw and neck muscle activities during rhythmic chewing. The phase in the peak frequency represented the temporal relationships between the jaw and neck muscle activities, while the non-chewing side neck muscle presented a broad range of distributions across jaw closing and opening phases. Coherence in the peak frequency represented the synergistic features in bilateral jaw closing muscles and chewing side neck muscle activities. The coherence and phase in non-chewing side neck muscle activities exhibited a significant negative correlation. From above, the bilateral coordination between the jaw and neck muscle activities is estimated while chewing when the non-chewing side neck muscle is synchronously activated with the jaw closing muscles, while the unilateral coordination is estimated when the non-chewing side neck muscle is irregularly activated in the jaw opening phase. Thus, the occurrence of bilateral or unilateral coordinated features in the jaw and neck muscle activities may correspond to the phase characteristics in the non-chewing side neck muscle activities during rhythmical chewing. Considering these novel findings in healthy subjects, EMG-EMG

  7. Analysis of using EMG and mechanical sensors to enhance intent recognition in powered lower limb prostheses

    NASA Astrophysics Data System (ADS)

    Young, A. J.; Kuiken, T. A.; Hargrove, L. J.

    2014-10-01

    Objective. The purpose of this study was to determine the contribution of electromyography (EMG) data, in combination with a diverse array of mechanical sensors, to locomotion mode intent recognition in transfemoral amputees using powered prostheses. Additionally, we determined the effect of adding time history information using a dynamic Bayesian network (DBN) for both the mechanical and EMG sensors. Approach. EMG signals from the residual limbs of amputees have been proposed to enhance pattern recognition-based intent recognition systems for powered lower limb prostheses, but mechanical sensors on the prosthesis—such as inertial measurement units, position and velocity sensors, and load cells—may be just as useful. EMG and mechanical sensor data were collected from 8 transfemoral amputees using a powered knee/ankle prosthesis over basic locomotion modes such as walking, slopes and stairs. An offline study was conducted to determine the benefit of different sensor sets for predicting intent. Main results. EMG information was not as accurate alone as mechanical sensor information (p < 0.05) for any classification strategy. However, EMG in combination with the mechanical sensor data did significantly reduce intent recognition errors (p < 0.05) both for transitions between locomotion modes and steady-state locomotion. The sensor time history (DBN) classifier significantly reduced error rates compared to a linear discriminant classifier for steady-state steps, without increasing the transitional error, for both EMG and mechanical sensors. Combining EMG and mechanical sensor data with sensor time history reduced the average transitional error from 18.4% to 12.2% and the average steady-state error from 3.8% to 1.0% when classifying level-ground walking, ramps, and stairs in eight transfemoral amputee subjects. Significance. These results suggest that a neural interface in combination with time history methods for locomotion mode classification can enhance intent

  8. Use of electromyography for the diagnosis of equine hyperkalemic periodic paresis.

    PubMed Central

    Robinson, J A; Naylor, J M; Crichlow, E C

    1990-01-01

    The use of electromyography (EMG) as a diagnostic aid for equine hyperkalemic periodic paresis (EHPP) was investigated in seven affected and seven control horses. Affected horses were confirmed positive for EHPP either by elevated serum potassium concentration with clinical signs of myotonia, or by inducing hyperkalemia and clinical signs using oral potassium chloride challenge. All horses were asymptomatic at the time EMG was performed, using bipolar fine wire needle electrodes. The myopotentials were recorded on magnetic tape and displayed on paper charts for analysis. Insertional and resting activity were recorded from the right supraspinatus, triceps, extensor carpi radialis and gluteal muscles in standing horses. Myotonic discharges were seen in six of seven affected horses but not in any of the controls. All seven affected horses and two control horses had prolonged insertional activity. Five out of seven affected horses and one control horse displayed spontaneous motor unit discharges unrelated to recording electrode movement. Myoelectrical potentials containing closely timed muscle potentials, i.e. doublets, were found in all affected horses, with four of seven affected horses also showing triplets. These potentials were not observed in any of the controls. No obvious difference in activity was observed among the four muscle sites tested. It is concluded that EMG is a safe and useful tool for diagnosing EHPP in horses not currently displaying clinical signs. Myotonic discharges and doublets appear to be the most diagnostically significant electromyographic abnormalities in EHPP affected horses. PMID:2249182

  9. High efficiency and simple technique for controlling mechanisms by EMG signals

    NASA Astrophysics Data System (ADS)

    Dugarte, N.; Álvarez, A.; Balacco, J.; Mercado, G.; Gonzalez, A.; Dugarte, E.; Javier, F.; Ceballos, G.; Olivares, A.

    2016-04-01

    This article reports the development of a simple and efficient system that allows control of mechanisms through electromyography (EMG) signals. The novelty about this instrument is focused on individual control of each motion vector mechanism through independent electronic circuits. Each of electronic circuit does positions a motor according to intensity of EMG signal captured. This action defines movement in one mechanical axis considered from an initial point, based on increased muscle tension. The final displacement of mechanism depends on individual’s ability to handle the levels of muscle tension at different body parts. This is the design of a robotic arm where each degree of freedom is handled with a specific microcontroller that responds to signals taken from a defined muscle. The biophysical interaction between the person and the final positioning of the robotic arm is used as feedback. Preliminary tests showed that the control operates with minimal positioning error margins. The constant use of system with the same operator showed that the person adapts and progressively improves at control technique.

  10. EMG-force relationship during static contraction: Effects on sensor placement locations on biceps brachii muscle.

    PubMed

    Ahamed, Nizam Uddin; Sundaraj, Kenneth; Alqahtani, Mahdi; Altwijri, Omar; Ali, Md Asraf; Islam, Md Anamul

    2014-10-15

    The relationship between surface electromyography (EMG) and force have been the subject of ongoing investigations and remain a subject of controversy. Even under static conditions, the relationships at different sensor placement locations in the biceps brachii (BB) muscle are complex. The aim of this study was to compare the activity and relationship between surface EMG and static force from the BB muscle in terms of three sensor placement locations. Twenty-one right hand dominant male subjects (age 25.3 ± 1.2 years) participated in the study. Surface EMG signals were detected from the subject's right BB muscle. The muscle activation during force was determined as the root mean square (RMS) electromyographic signal normalized to the peak RMS EMG signal of isometric contraction for 10 s. The statistical analysis included linear regression to examine the relationship between EMG amplitude and force of contraction [40-100% of maximal voluntary contraction (MVC)], repeated measures ANOVA to assess differences among the sensor placement locations, and coefficient of variation (CoV) for muscle activity variation. The results demonstrated that when the sensor was placed on the muscle belly, the linear slope coefficient was significantly greater for EMG versus force testing (r^{2} = 0.61, P > 0.05) than when placed on the lower part (r^{2}=0.31, P< 0.05) and upper part of the muscle belly (r^{2}=0.29, P > 0.05). In addition, the EMG signal activity on the muscle belly had less variability than the upper and lower parts (8.55% vs. 15.12% and 12.86%, respectively). These findings indicate the importance of applying the surface EMG sensor at the appropriate locations that follow muscle fiber orientation of the BB muscle during static contraction. As a result, EMG signals of three different placements may help to understand the difference in the amplitude of the signals due to placement.

  11. Spontaneous Facial Mimicry is Modulated by Joint Attention and Autistic Traits.

    PubMed

    Neufeld, Janina; Ioannou, Christina; Korb, Sebastian; Schilbach, Leonhard; Chakrabarti, Bhismadev

    2016-07-01

    Joint attention (JA) and spontaneous facial mimicry (SFM) are fundamental processes in social interactions, and they are closely related to empathic abilities. When tested independently, both of these processes have been usually observed to be atypical in individuals with autism spectrum conditions (ASC). However, it is not known how these processes interact with each other in relation to autistic traits. This study addresses this question by testing the impact of JA on SFM of happy faces using a truly interactive paradigm. Sixty-two neurotypical participants engaged in gaze-based social interaction with an anthropomorphic, gaze-contingent virtual agent. The agent either established JA by initiating eye contact or looked away, before looking at an object and expressing happiness or disgust. Eye tracking was used to make the agent's gaze behavior and facial actions contingent to the participants' gaze. SFM of happy expressions was measured by Electromyography (EMG) recording over the Zygomaticus Major muscle. Results showed that JA augments SFM in individuals with low compared with high autistic traits. These findings are in line with reports of reduced impact of JA on action imitation in individuals with ASC. Moreover, they suggest that investigating atypical interactions between empathic processes, instead of testing these processes individually, might be crucial to understanding the nature of social deficits in autism. Autism Res 2016, 9: 781-789. © 2015 The Authors Autism Research published by Wiley Periodicals, Inc. on behalf of International Society for Autism Research. © 2015 The Authors Autism Research published by Wiley Periodicals, Inc. on behalf of International Society for Autism Research.

  12. Evaluation of normal swallowing functions by using dynamic high-density surface electromyography maps.

    PubMed

    Zhu, Mingxing; Yu, Bin; Yang, Wanzhang; Jiang, Yanbing; Lu, Lin; Huang, Zhen; Chen, Shixiong; Li, Guanglin

    2017-11-21

    Swallowing is a continuous process with substantive interdependencies among different muscles, and it plays a significant role in our daily life. The aim of this study was to propose a novel technique based on high-density surface electromyography (HD sEMG) for the evaluation of normal swallowing functions. A total of 96 electrodes were placed on the front neck to acquire myoelectric signals from 12 healthy subjects while they were performing different swallowing tasks. HD sEMG energy maps were constructed based on the root mean square values to visualize muscular activities during swallowing. The effects of different volumes, viscosities, and head postures on the normal swallowing process were systemically investigated by using the energy maps. The results showed that the HD sEMG energy maps could provide detailed spatial and temporal properties of the muscle electrical activity, and visualize the muscle contractions that closely related to the swallowing function. The energy maps also showed that the swallowing time and effort was also explicitly affected by the volume and viscosity of the bolus. The concentration of the muscular activities shifted to the opposite side when the subjects turned their head to either side. The proposed method could provide an alternative method to physiologically evaluate the dynamic characteristics of normal swallowing and had the advantage of providing a full picture of how different muscle activities cooperate in time and location. The findings from this study suggested that the HD sEMG technique might be a useful tool for fast screening and objective assessment of swallowing disorders or dysphagia.

  13. A systematic review of surface electromyography analyses of the bench press movement task

    PubMed Central

    Gołaś, Artur; Blazek, Dusan; Maszczyk, Adam; Wilk, Michał; Pietraszewski, Przemysław; Petr, Miroslav; Uhlir, Petr; Zając, Adam

    2017-01-01

    Background The bench press exercise (BP) plays an important role in recreational and professional training, in which muscle activity is an important multifactorial phenomenon. The objective of this paper is to systematically review electromyography (EMG) studies performed on the barbell BP exercise to answer the following research questions: Which muscles show the greatest activity during the flat BP? Which changes in muscle activity are related to specific conditions under which the BP movement is performed? Strategy PubMed, Scopus, Web of Science and Cochrane Central Register of Controlled Trials (CENTRAL) in the Cochrane Library were searched through June 10, 2016. A combination of the following search terms was used: bench press, chest press, board press, test, measure, assessment, dynamometer, kinematics and biomechanics. Only original, full-text articles were considered. Results The search process resulted in 14 relevant studies that were included in the discussion. The triceps brachii (TB) and pectoralis major (PM) muscles were found to have similar activity during the BP, which was significantly higher than the activity of the anterior deltoid. During the BP movement, muscle activity changes with exercise intensity, velocity of movement, fatigue, mental focus, movement phase and stability conditions, such as bar vibration or unstable surfaces. Under these circumstances, TB is the most common object of activity change. Conclusions PM and TB EMG activity is more dominant and shows greater EMG amplitude than anterior deltoid during the BP. There are six factors that can influence muscle activity during the BP; however, the most important factor is exercise intensity, which interacts with all other factors. The research on muscle activity in the BP has several unresolved areas, such as clearly and strongly defined guidelines to perform EMG measurements (e.g., how to elaborate with surface EMG limits) or guidelines for the use of exact muscle models. PMID

  14. A systematic review of surface electromyography analyses of the bench press movement task.

    PubMed

    Stastny, Petr; Gołaś, Artur; Blazek, Dusan; Maszczyk, Adam; Wilk, Michał; Pietraszewski, Przemysław; Petr, Miroslav; Uhlir, Petr; Zając, Adam

    2017-01-01

    The bench press exercise (BP) plays an important role in recreational and professional training, in which muscle activity is an important multifactorial phenomenon. The objective of this paper is to systematically review electromyography (EMG) studies performed on the barbell BP exercise to answer the following research questions: Which muscles show the greatest activity during the flat BP? Which changes in muscle activity are related to specific conditions under which the BP movement is performed? PubMed, Scopus, Web of Science and Cochrane Central Register of Controlled Trials (CENTRAL) in the Cochrane Library were searched through June 10, 2016. A combination of the following search terms was used: bench press, chest press, board press, test, measure, assessment, dynamometer, kinematics and biomechanics. Only original, full-text articles were considered. The search process resulted in 14 relevant studies that were included in the discussion. The triceps brachii (TB) and pectoralis major (PM) muscles were found to have similar activity during the BP, which was significantly higher than the activity of the anterior deltoid. During the BP movement, muscle activity changes with exercise intensity, velocity of movement, fatigue, mental focus, movement phase and stability conditions, such as bar vibration or unstable surfaces. Under these circumstances, TB is the most common object of activity change. PM and TB EMG activity is more dominant and shows greater EMG amplitude than anterior deltoid during the BP. There are six factors that can influence muscle activity during the BP; however, the most important factor is exercise intensity, which interacts with all other factors. The research on muscle activity in the BP has several unresolved areas, such as clearly and strongly defined guidelines to perform EMG measurements (e.g., how to elaborate with surface EMG limits) or guidelines for the use of exact muscle models.

  15. Quantitative analysis of surface electromyography during epileptic and nonepileptic convulsive seizures.

    PubMed

    Beniczky, Sándor; Conradsen, Isa; Moldovan, Mihai; Jennum, Poul; Fabricius, Martin; Benedek, Krisztina; Andersen, Noémi; Hjalgrim, Helle; Wolf, Peter

    2014-07-01

    To investigate the characteristics of sustained muscle activation during convulsive epileptic and psychogenic nonepileptic seizures (PNES), as compared to voluntary muscle activation. The main goal was to find surface electromyography (EMG) features that can distinguish between convulsive epileptic seizures and convulsive PNES. In this case-control study, surface EMG was recorded from the deltoid muscles during long-term video-electroencephalography (EEG) monitoring in 25 patients and in 21 healthy controls. A total of 46 clinical episodes were recorded: 28 generalized tonic-clonic seizures (GTCS) from 14 patients with epilepsy, and 18 convulsive PNES from 12 patients (one patient had both GTCS and PNES). The healthy controls were simulating GTCS. To quantitatively characterize the signals we calculated the following parameters: root mean square (RMS) of the amplitude, median frequency (MF), coherence, and duration of the seizures, of the clonic EMG discharges, and of the silent periods between the cloni. Based on wavelet analysis, we distinguished between a low-frequency component (LF 2-8 Hz) and a high-frequency component (HF 64-256 Hz). Duration of the seizure, and separation between the tonic and the clonic phases distinguished at group-level but not at individual level between convulsive PNES and GTCS. RMS, temporal dynamics of the HF/LF ratio, and the evolution of the silent periods differentiated between epileptic and nonepileptic convulsive seizures at the individual level. A combination between HF/LF ratio and RMS separated all PNES from the GTCS. A blinded review of the EMG features distinguished correctly between GTCS and convulsive PNES in all cases. The HF/LF ratio and the RMS of the PNES were smaller compared to the simulated seizures. In addition to providing insight into the mechanism of muscle activation during convulsive PNES, these results have diagnostic significance, at the individual level. Surface EMG features can accurately distinguish

  16. Imaging seizure activity: a combined EEG/EMG-fMRI study in reading epilepsy.

    PubMed

    Salek-Haddadi, Afraim; Mayer, Thomas; Hamandi, Khalid; Symms, Mark; Josephs, Oliver; Fluegel, Dominique; Woermann, Friedrich; Richardson, Mark P; Noppeney, Uta; Wolf, Peter; Koepp, Matthias J

    2009-02-01

    To characterize the spatial relationship between activations related to language-induced seizure activity, language processing, and motor control in patients with reading epilepsy. We recorded and simultaneously monitored several physiological parameters [voice-recording, electromyography (EMG), electrocardiography (ECG), electroencephalography (EEG)] during blood oxygen level-dependent (BOLD) functional magnetic resonance imaging (fMRI) in nine patients with reading epilepsy. Individually tailored language paradigms were used to induce and record habitual seizures inside the MRI scanner. Voxel-based morphometry (VBM) was used for structural brain analysis. Reading-induced seizures occurred in six out of nine patients. One patient experienced abundant orofacial reflex myocloni during silent reading in association with bilateral frontal or generalized epileptiform discharges. In a further five patients, symptoms were only elicited while reading aloud with self-indicated events. Consistent activation patterns in response to reading-induced myoclonic seizures were observed within left motor and premotor areas in five of these six patients, in the left striatum (n = 4), in mesiotemporal/limbic areas (n = 4), in Brodmann area 47 (n = 3), and thalamus (n = 2). These BOLD activations were overlapping or adjacent to areas physiologically activated during language and facial motor tasks. No subtle structural abnormalities common to all patients were identified using VBM, but one patient had a left temporal ischemic lesion. Based on the findings, we hypothesize that reflex seizures occur in reading epilepsy when a critical mass of neurons are activated through a provoking stimulus within corticoreticular and corticocortical circuitry subserving normal functions.

  17. A cross-sectional electromyography assessment in linear scleroderma patients

    PubMed Central

    2014-01-01

    Background Muscle atrophy and asymmetric extremity growth is a common feature of linear scleroderma (LS). Extra-cutaneous features are also common and primary neurologic involvement, with sympathetic dysfunction, may have a pathogenic role in subcutaneous and muscle atrophy. The aim was investigate nerve conduction and muscle involvement by electromyography in pediatric patients with LS. Methods We conducted a retrospective review of LS pediatric patients who had regular follow up at a single pediatric center from 1997–2013. We selected participants if they had consistently good follow up and enrolled consecutive patients in the study. We examined LS photos as well as clinical, serological and imaging findings. Electromyograms (EMG) were performed with bilateral symmetric technique, using surface and needle electrodes, comparing the affected side with the contralateral side. Abnormal muscle activity was categorized as a myopathic or neurogenic pattern. Results Nine LS subjects were selected for EMG, 2 with Parry-Romberg/Hemifacial Atrophy Syndrome, 7 linear scleroderma of an extremity and 2 with mixed forms (linear and morphea). Electromyogram analysis indicated that all but one had asymmetric myopathic pattern in muscles underlying the linear streaks. Motor and sensory nerve conduction was also evaluated in upper and lower limbs and one presented a neurogenic pattern. Masticatory muscle testing showed a myopathic pattern in the atrophic face of 2 cases with head and face involvement. Conclusion In our small series of LS patients, we found a surprising amount of muscle dysfunction by EMG. The muscle involvement may be possibly related to a secondary peripheral nerve involvement due to LS inflammation and fibrosis. Further collaborative studies to confirm these findings are needed. PMID:25053924

  18. Assessment of Parturition with Cervical Light-Induced Fluorescence and Uterine Electromyography

    PubMed Central

    Lucovnik, Miha; Kuon, Ruben J.; Garfield, Robert E.

    2013-01-01

    Parturition involves increasing compliance (ripening) of the uterine cervix and activation of the myometrium. These processes take place in a different time frame. Softening and shortening of the cervix starts in midpregnancy, while myometrial activation occurs relatively close to delivery. Methods currently available to clinicians to assess cervical and myometrial changes are subjective and inaccurate, which often causes misjudgments with potentially adverse consequences. The inability to reliably diagnose true preterm labor leads to unnecessary treatments, missed opportunities to improve neonatal outcome, and inherently biased research of treatments. At term, the likelihood of cesarean delivery depends on labor management, which in turn depends on accurate assessments of cervical change and myometrial contractility. Studies from our group and others show that noninvasive measurements of light-induced fluorescence (LIF) of cervical collagen and uterine electromyography (EMG) objectively detect changes in the composition of the cervix and myometrial preparedness to labor and are more reliable than clinical observations alone. We present a conceptual model of parturition constructed on cervical LIF and uterine EMG studies. We also explore how these methodologies could be helpful with managing patients experiencing preterm contractions and with optimizing labor management protocols aimed to reduce cesarean section. PMID:24187578

  19. Reproducibility of 3D kinematics and surface electromyography measurements of mastication.

    PubMed

    Remijn, Lianne; Groen, Brenda E; Speyer, Renée; van Limbeek, Jacques; Nijhuis-van der Sanden, Maria W G

    2016-03-01

    The aim of this study was to determine the measurement reproducibility for a procedure evaluating the mastication process and to estimate the smallest detectable differences of 3D kinematic and surface electromyography (sEMG) variables. Kinematics of mandible movements and sEMG activity of the masticatory muscles were obtained over two sessions with four conditions: two food textures (biscuit and bread) of two sizes (small and large). Twelve healthy adults (mean age 29.1 years) completed the study. The second to the fifth chewing cycle of 5 bites were used for analyses. The reproducibility per outcome variable was calculated with an intraclass correlation coefficient (ICC) and a Bland-Altman analysis was applied to determine the standard error of measurement relative error of measurement and smallest detectable differences of all variables. ICCs ranged from 0.71 to 0.98 for all outcome variables. The outcome variables consisted of four bite and fourteen chewing cycle variables. The relative standard error of measurement of the bite variables was up to 17.3% for 'time-to-swallow', 'time-to-transport' and 'number of chewing cycles', but ranged from 31.5% to 57.0% for 'change of chewing side'. The relative standard error of measurement ranged from 4.1% to 24.7% for chewing cycle variables and was smaller for kinematic variables than sEMG variables. In general, measurements obtained with 3D kinematics and sEMG are reproducible techniques to assess the mastication process. The duration of the chewing cycle and frequency of chewing were the best reproducible measurements. Change of chewing side could not be reproduced. The published measurement error and smallest detectable differences will aid the interpretation of the results of future clinical studies using the same study variables. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. Intramuscular pressure: A better tool than EMG to optimize exercise for long-duration space flight

    NASA Technical Reports Server (NTRS)

    Hargens, A. R.; Ballard, R. E.; Aratow, M.; Crenshaw, A.; Styf, J.; Kahan, N.; Watenpaugh, D. E.

    1992-01-01

    A serious problem experienced by astronauts during long-duration space flight is muscle atrophy. In order to develop countermeasures for this problem, a simple method for monitoring in vivo function of specific muscles is needed. Previous studies document that both intramuscular pressure (IMP) and electromyography (EMG) provide quantitative indices of muscle contraction force during isometric exercise. However, at present there are no data available concerning the usefulness of IMP versus EMG during dynamic exercise. Methods: IMP (Myopress catheter) and surface EMG activity were measured continuously and simultaneously in the tibalis anterior (TA) and soleus (SOL) muscles of 9 normal male volunteers (28-54 years). These parameters were recorded during both concentric and eccentric exercises which consisted of plantarflexon and dorsiflexon of the ankle joint. A Lido Active Isokinetic Dynamometer concurrently recorded ankle joint torque and position. Results: Intramuscular pressure correlated linearly with contraction force for both SOL (r exp 2 = 0.037) and TA (R exp 2 = 0.716 and r exp 2 = 0.802, respectively). During eccentric exercises, SOL and TA IMP also correlated linearly with contraction force (r(exp 2) = 0.883 and r(exp 2) = 0.904 respectively), but SOL and TA EMG correlated poorly with force (r(exp 2) = 0.489 and r(exp 2) = 0.702 respectively). Conclusion: IMP measurement provides a better index of muscle contraction force than EMG during concentric and eccentric exercise. IMP reflects intrinsic mechanical properties of individual muscles, such as length tension relationships. Although invasive, IMP provides a more powerful tool and EMG for developing exercise hardware and protocols for astronauts exposed to long-duration space flight.

  1. Validity and Reliability of Surface Electromyography Measurements from a Wearable Athlete Performance System

    PubMed Central

    Lynn, Scott K.; Watkins, Casey M.; Wong, Megan A.; Balfany, Katherine; Feeney, Daniel F.

    2018-01-01

    The Athos ® wearable system integrates surface electromyography (sEMG ) electrodes into the construction of compression athletic apparel. The Athos system reduces the complexity and increases the portability of collecting EMG data and provides processed data to the end user. The objective of the study was to determine the reliability and validity of Athos as compared with a research grade sEMG system. Twelve healthy subjects performed 7 trials on separate days (1 baseline trial and 6 repeated trials). In each trial subjects wore the wearable sEMG system and had a research grade sEMG system’s electrodes placed just distal on the same muscle, as close as possible to the wearable system’s electrodes. The muscles tested were the vastus lateralis (VL), vastus medialis (VM), and biceps femoris (BF). All testing was done on an isokinetic dynamometer. Baseline testing involved performing isometric 1 repetition maximum tests for the knee extensors and flexors and three repetitions of concentric-concentric knee flexion and extension at MVC for each testing speed: 60, 180, and 300 deg/sec. Repeated trials 2-7 each comprised 9 sets where each set included three repetitions of concentric-concentric knee flexion-extension. Each repeated trial (2-7) comprised one set at each speed and percent MVC (50%, 75%, 100%) combination. The wearable system and research grade sEMG data were processed using the same methods and aligned in time. The amplitude metrics calculated from the sEMG for each repetition were the peak amplitude, sum of the linear envelope, and 95th percentile. Validity results comprise two main findings. First, there is not a significant effect of system (Athos or research grade system) on the repetition amplitude metrics (95%, peak, or sum). Second, the relationship between torque and sEMG is not significantly different between Athos and the research grade system. For reliability testing, the variation across trials and averaged across speeds was 0.8%, 7.3%, and 0

  2. EMGD-FE: an open source graphical user interface for estimating isometric muscle forces in the lower limb using an EMG-driven model

    PubMed Central

    2014-01-01

    Background This paper describes the “EMG Driven Force Estimator (EMGD-FE)”, a Matlab® graphical user interface (GUI) application that estimates skeletal muscle forces from electromyography (EMG) signals. Muscle forces are obtained by numerically integrating a system of ordinary differential equations (ODEs) that simulates Hill-type muscle dynamics and that utilises EMG signals as input. In the current version, the GUI can estimate the forces of lower limb muscles executing isometric contractions. Muscles from other parts of the body can be tested as well, although no default values for model parameters are provided. To achieve accurate evaluations, EMG collection is performed simultaneously with torque measurement from a dynamometer. The computer application guides the user, step-by-step, to pre-process the raw EMG signals, create inputs for the muscle model, numerically integrate the ODEs and analyse the results. Results An example of the application’s functions is presented using the quadriceps femoris muscle. Individual muscle force estimations for the four components as well the knee isometric torque are shown. Conclusions The proposed GUI can estimate individual muscle forces from EMG signals of skeletal muscles. The estimation accuracy depends on several factors, including signal collection and modelling hypothesis issues. PMID:24708668

  3. Simultaneous and Continuous Estimation of Shoulder and Elbow Kinematics from Surface EMG Signals

    PubMed Central

    Zhang, Qin; Liu, Runfeng; Chen, Wenbin; Xiong, Caihua

    2017-01-01

    In this paper, we present a simultaneous and continuous kinematics estimation method for multiple DoFs across shoulder and elbow joint. Although simultaneous and continuous kinematics estimation from surface electromyography (EMG) is a feasible way to achieve natural and intuitive human-machine interaction, few works investigated multi-DoF estimation across the significant joints of upper limb, shoulder and elbow joints. This paper evaluates the feasibility to estimate 4-DoF kinematics at shoulder and elbow during coordinated arm movements. Considering the potential applications of this method in exoskeleton, prosthetics and other arm rehabilitation techniques, the estimation performance is presented with different muscle activity decomposition and learning strategies. Principle component analysis (PCA) and independent component analysis (ICA) are respectively employed for EMG mode decomposition with artificial neural network (ANN) for learning the electromechanical association. Four joint angles across shoulder and elbow are simultaneously and continuously estimated from EMG in four coordinated arm movements. By using ICA (PCA) and single ANN, the average estimation accuracy 91.12% (90.23%) is obtained in 70-s intra-cross validation and 87.00% (86.30%) is obtained in 2-min inter-cross validation. This result suggests it is feasible and effective to use ICA (PCA) with single ANN for multi-joint kinematics estimation in variant application conditions. PMID:28611573

  4. A comparison of electromyography and stroke kinematics during ergometer and on-water rowing.

    PubMed

    Fleming, Neil; Donne, Bernard; Mahony, Nicholas

    2014-01-01

    This study assessed muscle recruitment patterns and stroke kinematics during ergometer and on-water rowing to validate the accuracy of rowing ergometry. Male rowers (n = 10; age 21 ± 2 years, height 1.90 ± 0.05 m and body mass 83.3 ± 4.8 kg) performed 3 × 3 min exercise bouts, at heart and stroke rates equivalent to 75, 85 and 95% VO2peak, on both dynamic and stationary rowing ergometers, and on water. During exercise, synchronised data for surface electromyography (EMG) and 2D kinematics were recorded. Overall muscle activity was quantified by the integration of rmsEMG and averaged for each 10% interval of the stroke cycle. Muscle activity significantly increased in rectus femoris (RF) and vastus medialis (VM) (P <0.01), as exercise intensity increased. Comparing EMG data across conditions revealed significantly (P <0.05) greater RF and VM activity during on-water rowing at discrete 10% intervals of stroke cycle. In addition, the drive/recovery ratio was significantly lower during dynamic ergometry compared to on-water (40 ± 1 vs. 44 ± 1% at 95%, P <0.01). Results suggest that significant differences exist while comparing recruitment and kinematic patterns between on-water and ergometer rowing. These differences may be due to altered acceleration and deceleration of moving masses on-ergometer not perfectly simulating the on-water scenario.

  5. Effect of spatial filtering on crosstalk reduction in surface EMG recordings.

    PubMed

    Mesin, Luca; Smith, Stuart; Hugo, Suzanne; Viljoen, Suretha; Hanekom, Tania

    2009-04-01

    Increasing the selectivity of the detection system in surface electromyography (EMG) is beneficial in the collection of information of a specific portion of the investigated muscle and to reduce the contribution of undesired components, such as non-propagating components (due to generation or end-of-fibre effects) or crosstalk from nearby muscles. A comparison of the ability of different spatial filters to reduce the amount of crosstalk in surface EMG measurements was conducted in this paper using simulated signals. It focused on the influence of different properties of the muscle anatomy (changing subcutaneous layer thickness, skin conductivity, fibre length) and detection system (single, double and normal double differential, with two inter-electrode distances - IED) on the amount of crosstalk present in the measurements. A cylindrical multilayer (skin, subcutaneous tissue, muscle, bone) analytical model was used to simulate single fibre action potentials (SFAPs). Fibres were grouped together in motor units (MUs) and motor unit action potentials (MUAPs) were obtained by adding the SFAPs of the corresponding fibres. Interference surface EMG signals were obtained, modelling the recruitment of MUs and rate coding. The average rectified value (ARV) and mean frequency (MNF) content of the EMG signals were studied and used as a basis for determining the selectivity of each spatial filter. From these results it was found that the selectivity of each spatial filter varies depending on the transversal location of the measurement electrodes and on the anatomy. An increase in skin conductivity favourably affects the selectivity of normal double differential filters as does an increase in subcutaneous layer thickness. An increase in IED decreases the selectivity of all the analysed filters.

  6. Analysis of prosody in finger braille using electromyography.

    PubMed

    Miyagi, Manabi; Nishida, Masafumi; Horiuchi, Yasuo; Ichikawa, Akira

    2006-01-01

    Finger braille is one of the communication methods for the deaf blind. The interpreter types braille codes on the fingers of deaf blind. Finger braille seems to be the most suitable medium for real-time communication by its speed and accuracy of transmitting characters. We hypothesize that the prosody information exists in the time structure and strength of finger braille typing. Prosody is the paralinguistic information that has functions to transmit the sentence structure, prominence, emotions and other form of information in real time communication. In this study, we measured the surface electromyography (sEMG) of finger movement to analyze the typing strength of finger braille. We found that the typing strength increases at the beginning of a phrase and a prominent phrase. The result shows the possibility that the prosody in the typing strength of finger braille can be applied to create an interpreter system for the deafblind.

  7. A patient-specific EMG-driven neuromuscular model for the potential use of human-inspired gait rehabilitation robots.

    PubMed

    Ma, Ye; Xie, Shengquan; Zhang, Yanxin

    2016-03-01

    A patient-specific electromyography (EMG)-driven neuromuscular model (PENm) is developed for the potential use of human-inspired gait rehabilitation robots. The PENm is modified based on the current EMG-driven models by decreasing the calculation time and ensuring good prediction accuracy. To ensure the calculation efficiency, the PENm is simplified into two EMG channels around one joint with minimal physiological parameters. In addition, a dynamic computation model is developed to achieve real-time calculation. To ensure the calculation accuracy, patient-specific muscle kinematics information, such as the musculotendon lengths and the muscle moment arms during the entire gait cycle, are employed based on the patient-specific musculoskeletal model. Moreover, an improved force-length-velocity relationship is implemented to generate accurate muscle forces. Gait analysis data including kinematics, ground reaction forces, and raw EMG signals from six adolescents at three different speeds were used to evaluate the PENm. The simulation results show that the PENm has the potential to predict accurate joint moment in real-time. The design of advanced human-robot interaction control strategies and human-inspired gait rehabilitation robots can benefit from the application of the human internal state provided by the PENm. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Effects of electrocardiography contamination and comparison of ECG removal methods on upper trapezius electromyography recordings.

    PubMed

    Marker, Ryan J; Maluf, Katrina S

    2014-12-01

    Electromyography (EMG) recordings from the trapezius are often contaminated by the electrocardiography (ECG) signal, making it difficult to distinguish low-level muscle activity from muscular rest. This study investigates the influence of ECG contamination on EMG amplitude and frequency estimations in the upper trapezius during muscular rest and low-level contractions. A new method of ECG contamination removal, filtered template subtraction (FTS), is described and compared to 30 Hz high-pass filter (HPF) and averaged template subtraction (ATS) methods. FTS creates a unique template of each ECG artifact using a low-pass filtered copy of the contaminated signal, which is subtracted from contaminated periods in the original signal. ECG contamination results in an over-estimation of EMG amplitude during rest in the upper trapezius, with negligible effects on amplitude and frequency estimations during low-intensity isometric contractions. FTS and HPF successfully removed ECG contamination from periods of muscular rest, yet introduced errors during muscle contraction. Conversely, ATS failed to fully remove ECG contamination during muscular rest, yet did not introduce errors during muscle contraction. The relative advantages and disadvantages of different ECG contamination removal methods should be considered in the context of the specific motor tasks that require analysis. Copyright © 2014 Elsevier Ltd. All rights reserved.

  9. Perception of face and body expressions using electromyography, pupillometry and gaze measures.

    PubMed

    Kret, Mariska E; Stekelenburg, Jeroen J; Roelofs, Karin; de Gelder, Beatrice

    2013-01-01

    Traditional emotion theories stress the importance of the face in the expression of emotions but bodily expressions are becoming increasingly important as well. In these experiments we tested the hypothesis that similar physiological responses can be evoked by observing emotional face and body signals and that the reaction to angry signals is amplified in anxious individuals. We designed three experiments in which participants categorized emotional expressions from isolated facial and bodily expressions and emotionally congruent and incongruent face-body compounds. Participants' fixations were measured and their pupil size recorded with eye-tracking equipment and their facial reactions measured with electromyography. The results support our prediction that the recognition of a facial expression is improved in the context of a matching posture and importantly, vice versa as well. From their facial expressions, it appeared that observers acted with signs of negative emotionality (increased corrugator activity) to angry and fearful facial expressions and with positive emotionality (increased zygomaticus) to happy facial expressions. What we predicted and found, was that angry and fearful cues from the face or the body, attracted more attention than happy cues. We further observed that responses evoked by angry cues were amplified in individuals with high anxiety scores. In sum, we show that people process bodily expressions of emotion in a similar fashion as facial expressions and that the congruency between the emotional signals from the face and body facilitates the recognition of the emotion.

  10. Perception of Face and Body Expressions Using Electromyography, Pupillometry and Gaze Measures

    PubMed Central

    Kret, Mariska E.; Stekelenburg, Jeroen J.; Roelofs, Karin; de Gelder, Beatrice

    2013-01-01

    Traditional emotion theories stress the importance of the face in the expression of emotions but bodily expressions are becoming increasingly important as well. In these experiments we tested the hypothesis that similar physiological responses can be evoked by observing emotional face and body signals and that the reaction to angry signals is amplified in anxious individuals. We designed three experiments in which participants categorized emotional expressions from isolated facial and bodily expressions and emotionally congruent and incongruent face-body compounds. Participants’ fixations were measured and their pupil size recorded with eye-tracking equipment and their facial reactions measured with electromyography. The results support our prediction that the recognition of a facial expression is improved in the context of a matching posture and importantly, vice versa as well. From their facial expressions, it appeared that observers acted with signs of negative emotionality (increased corrugator activity) to angry and fearful facial expressions and with positive emotionality (increased zygomaticus) to happy facial expressions. What we predicted and found, was that angry and fearful cues from the face or the body, attracted more attention than happy cues. We further observed that responses evoked by angry cues were amplified in individuals with high anxiety scores. In sum, we show that people process bodily expressions of emotion in a similar fashion as facial expressions and that the congruency between the emotional signals from the face and body facilitates the recognition of the emotion. PMID:23403886

  11. Validity and Reliability of Surface Electromyography in the Assessment of Primary Muscle Tension Dysphonia.

    PubMed

    Khoddami, Seyyedeh Maryam; Talebian, Saeed; Izadi, Farzad; Ansari, Noureddin Nakhostin

    2017-05-01

    The study aims to evaluate the reliability and the discriminative validity of surface electromyography (sEMG) in the assessment of patients with primary muscle tension dysphonia (MTD). The study design is cross-sectional. Fifteen patients with primary MTD (mean age: 34.07 ± 10.99 years) and 15 healthy volunteers (mean age: 34.53 ± 10.63 years) were included. All participants underwent evaluation of sEMG to record the electrical activity of the thyrohyoid and cricothyroid muscles. The outcome measures were the root mean square (RMS), activity peak, duration, and time to the peak activity, which were obtained during /a/ and /i/ prolongation for test-retest reliability. The test-retest reliability was good to excellent for the RMS and peak activity measures (intraclass correlation coefficient [agreement] [ICC agreement ] = 0.49-0.98). The reliability for the activity duration was poor to excellent (ICC agreement  = 0.19-0.9). Poor test-retest reliability was found for the time to peak measure (ICC agreement  = 0.15-0.37). The standard error of measurement for all sEMG measures was between 0.41 and 2.05. The smallest detectable change (SDC) was calculated between 1.13 and 5.66. The highest SDC values were obtained for the peak and the lowest SDCs were documented for the duration (5.66 and 1.13, respectively). All sEMG measures were not able to discriminate between the MTD patients and healthy subjects (P > 0.05). The sEMG is a reliable tool to measure the RMS, the peak activity, and the activity duration in primary MTD. However, it is not able to discriminate the patients with primary MTD from healthy subjects. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  12. The influence of digital filter type, amplitude normalisation method, and co-contraction algorithm on clinically relevant surface electromyography data during clinical movement assessments.

    PubMed

    Devaprakash, Daniel; Weir, Gillian J; Dunne, James J; Alderson, Jacqueline A; Donnelly, Cyril J

    2016-12-01

    There is a large and growing body of surface electromyography (sEMG) research using laboratory-specific signal processing procedures (i.e., digital filter type and amplitude normalisation protocols) and data analyses methods (i.e., co-contraction algorithms) to acquire practically meaningful information from these data. As a result, the ability to compare sEMG results between studies is, and continues to be challenging. The aim of this study was to determine if digital filter type, amplitude normalisation method, and co-contraction algorithm could influence the practical or clinical interpretation of processed sEMG data. Sixteen elite female athletes were recruited. During data collection, sEMG data was recorded from nine lower limb muscles while completing a series of calibration and clinical movement assessment trials (running and sidestepping). Three analyses were conducted: (1) signal processing with two different digital filter types (Butterworth or critically damped), (2) three amplitude normalisation methods, and (3) three co-contraction ratio algorithms. Results showed the choice of digital filter did not influence the clinical interpretation of sEMG; however, choice of amplitude normalisation method and co-contraction algorithm did influence the clinical interpretation of the running and sidestepping task. Care is recommended when choosing amplitude normalisation method and co-contraction algorithms if researchers/clinicians are interested in comparing sEMG data between studies. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. A neurophysiological study of facial numbness in multiple sclerosis: Integration with clinical data and imaging findings.

    PubMed

    Koutsis, Georgios; Kokotis, Panagiotis; Papagianni, Aikaterini E; Evangelopoulos, Maria-Eleftheria; Kilidireas, Constantinos; Karandreas, Nikolaos

    2016-09-01

    To integrate neurophysiological findings with clinical and imaging data in a consecutive series of multiple sclerosis (MS) patients developing facial numbness during the course of an MS attack. Nine consecutive patients with MS and recent-onset facial numbness were studied clinically, imaged with routine MRI, and assessed neurophysiologically with trigeminal somatosensory evoked potential (TSEP), blink reflex (BR), masseter reflex (MR), facial nerve conduction, facial muscle and masseter EMG studies. All patients had unilateral facial hypoesthesia on examination and lesions in the ipsilateral pontine tegmentum on MRI. All patients had abnormal TSEPs upon stimulation of the affected side, excepting one that was tested following remission of numbness. BR was the second most sensitive neurophysiological method with 6/9 examinations exhibiting an abnormal R1 component. The MR was abnormal in 3/6 patients, always on the affected side. Facial conduction and EMG studies were normal in all patients but one. Facial numbness was always related to abnormal TSEPs. A concomitant R1 abnormality on BR allowed localization of the responsible pontine lesion, which closely corresponded with MRI findings. We conclude that neurophysiological assessment of MS patients with facial numbness is a sensitive tool, which complements MRI, and can improve lesion localization. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Self-Recalibrating Surface EMG Pattern Recognition for Neuroprosthesis Control Based on Convolutional Neural Network

    PubMed Central

    Zhai, Xiaolong; Jelfs, Beth; Chan, Rosa H. M.; Tin, Chung

    2017-01-01

    Hand movement classification based on surface electromyography (sEMG) pattern recognition is a promising approach for upper limb neuroprosthetic control. However, maintaining day-to-day performance is challenged by the non-stationary nature of sEMG in real-life operation. In this study, we propose a self-recalibrating classifier that can be automatically updated to maintain a stable performance over time without the need for user retraining. Our classifier is based on convolutional neural network (CNN) using short latency dimension-reduced sEMG spectrograms as inputs. The pretrained classifier is recalibrated routinely using a corrected version of the prediction results from recent testing sessions. Our proposed system was evaluated with the NinaPro database comprising of hand movement data of 40 intact and 11 amputee subjects. Our system was able to achieve ~10.18% (intact, 50 movement types) and ~2.99% (amputee, 10 movement types) increase in classification accuracy averaged over five testing sessions with respect to the unrecalibrated classifier. When compared with a support vector machine (SVM) classifier, our CNN-based system consistently showed higher absolute performance and larger improvement as well as more efficient training. These results suggest that the proposed system can be a useful tool to facilitate long-term adoption of prosthetics for amputees in real-life applications. PMID:28744189

  15. Self-Recalibrating Surface EMG Pattern Recognition for Neuroprosthesis Control Based on Convolutional Neural Network.

    PubMed

    Zhai, Xiaolong; Jelfs, Beth; Chan, Rosa H M; Tin, Chung

    2017-01-01

    Hand movement classification based on surface electromyography (sEMG) pattern recognition is a promising approach for upper limb neuroprosthetic control. However, maintaining day-to-day performance is challenged by the non-stationary nature of sEMG in real-life operation. In this study, we propose a self-recalibrating classifier that can be automatically updated to maintain a stable performance over time without the need for user retraining. Our classifier is based on convolutional neural network (CNN) using short latency dimension-reduced sEMG spectrograms as inputs. The pretrained classifier is recalibrated routinely using a corrected version of the prediction results from recent testing sessions. Our proposed system was evaluated with the NinaPro database comprising of hand movement data of 40 intact and 11 amputee subjects. Our system was able to achieve ~10.18% (intact, 50 movement types) and ~2.99% (amputee, 10 movement types) increase in classification accuracy averaged over five testing sessions with respect to the unrecalibrated classifier. When compared with a support vector machine (SVM) classifier, our CNN-based system consistently showed higher absolute performance and larger improvement as well as more efficient training. These results suggest that the proposed system can be a useful tool to facilitate long-term adoption of prosthetics for amputees in real-life applications.

  16. Development of a 3D workspace shoulder assessment tool incorporating electromyography and an inertial measurement unit-a preliminary study.

    PubMed

    Aslani, Navid; Noroozi, Siamak; Davenport, Philip; Hartley, Richard; Dupac, Mihai; Sewell, Philip

    2018-06-01

    Traditional shoulder range of movement (ROM) measurement tools suffer from inaccuracy or from long experimental setup times. Recently, it has been demonstrated that relatively low-cost wearable inertial measurement unit (IMU) sensors can overcome many of the limitations of traditional motion tracking systems. The aim of this study is to develop and evaluate a single IMU combined with an electromyography (EMG) sensor to monitor the 3D reachable workspace with simultaneous measurement of deltoid muscle activity across the shoulder ROM. Six volunteer subjects with healthy shoulders and one participant with a 'frozen' shoulder were recruited to the study. Arm movement in 3D space was plotted in spherical coordinates while the relative EMG intensity of any arm position is presented graphically. The results showed that there was an average ROM surface area of 27291 ± 538 deg 2 among all six healthy individuals and a ROM surface area of 13571 ± 308 deg 2 for the subject with frozen shoulder. All three sections of the deltoid show greater EMG activity at higher elevation angles. Using such tools enables individuals, surgeons and physiotherapists to measure the maximum envelope of motion in conjunction with muscle activity in order to provide an objective assessment of shoulder performance in the voluntary 3D workspace. Graphical abstract The aim of this study is to develop and evaluate a single IMU combined with an electromyography (EMG) sensor to monitor the 3D reachable workspace with simultaneous measurement of deltoid muscle activity across the shoulder ROM. The assessment tool consists of an IMU sensor, an EMG sensor, a microcontroller and a Bluetooth module. The assessment tool was attached to subjects arm. Individuals were instructed to move their arms with the elbow fully extended. They were then asked to provide the maximal voluntary elevation envelope of the arm in 3D space in multiple attempts starting from a small movement envelope going to the biggest

  17. Recognition of hand movements in a trans-radial amputated subject by sEMG.

    PubMed

    Atzori, Manfredo; Muller, Henning; Baechler, Micheal

    2013-06-01

    Trans-radially amputated persons who own a myoelectric prosthesis have currently some control via surface electromyography (sEMG). However, the control systems are still limited (as they include very few movements) and not always natural (as the subject has to learn to associate movements of the muscles with the movements of the prosthesis). The Ninapro project tries helping the scientific community to overcome these limits through the creation of electromyography data sources to test machine learning algorithms. In this paper the results gained from first tests made on an amputated subject with the Ninapro acquisition protocol are detailed. In agreement with neurological studies on cortical plasticity and on the anatomy of the forearm, the amputee produced stable signals for each movement in the test. Using a k-NN classification algorithm, we obtain an average classification rate of 61.5% on all 53 movements. Successively, we simplify the task reducing the number of movements to 13, resulting in no misclassified movements. This shows that for fewer movements a very high classification accuracy is possible without the subject having to learn the movements specifically.

  18. Design of sEMG assembly to detect external anal sphincter activity: a proof of concept.

    PubMed

    Shiraz, Arsam; Leaker, Brian; Mosse, Charles Alexander; Solomon, Eskinder; Craggs, Michael; Demosthenous, Andreas

    2017-10-31

    Conditional trans-rectal stimulation of the pudendal nerve could provide a viable solution to treat hyperreflexive bladder in spinal cord injury. A set threshold of the amplitude estimate of the external anal sphincter surface electromyography (sEMG) may be used as the trigger signal. The efficacy of such a device should be tested in a large scale clinical trial. As such, a probe should remain in situ for several hours while patients attend to their daily routine; the recording electrodes should be designed to be large enough to maintain good contact while observing design constraints. The objective of this study was to arrive at a design for intra-anal sEMG recording electrodes for the subsequent clinical trials while deriving the possible recording and processing parameters. Having in mind existing solutions and based on theoretical and anatomical considerations, a set of four multi-electrode probes were designed and developed. These were tested in a healthy subject and the measured sEMG traces were recorded and appropriately processed. It was shown that while comparatively large electrodes record sEMG traces that are not sufficiently correlated with the external anal sphincter contractions, smaller electrodes may not maintain a stable electrode tissue contact. It was shown that 3 mm wide and 1 cm long electrodes with 5 mm inter-electrode spacing, in agreement with Nyquist sampling, placed 1 cm from the orifice may intra-anally record a sEMG trace sufficiently correlated with external anal sphincter activity. The outcome of this study can be used in any biofeedback, treatment or diagnostic application where the activity of the external anal sphincter sEMG should be detected for an extended period of time.

  19. Eversion Strength and Surface Electromyography Measures With and Without Chronic Ankle Instability Measured in 2 Positions.

    PubMed

    Donnelly, Lindsy; Donovan, Luke; Hart, Joseph M; Hertel, Jay

    2017-07-01

    Individuals with chronic ankle instability (CAI) have demonstrated strength deficits compared to healthy controls; however, the influence of ankle position on force measures and surface electromyography (sEMG) activation of the peroneus longus and brevis has not been investigated. The purpose of this study was to compare sEMG amplitudes of the peroneus longus and brevis and eversion force measures in 2 testing positions, neutral and plantarflexion, in groups with and without CAI. Twenty-eight adults (19 females, 9 males) with CAI and 28 healthy controls (19 females, 9 males) participated. Hand-held dynamometer force measures were assessed during isometric eversion contractions in 2 testing positions (neutral, plantarflexion) while surface sEMG amplitudes of the peroneal muscles were recorded. Force measures were normalized to body mass, and sEMG amplitudes were normalized to a resting period. The group with CAI demonstrated less force when compared to the control group ( P < .001) in both the neutral and plantarflexion positions: neutral position, CAI: 1.64 Nm/kg and control: 2.10 Nm/kg) and plantarflexion position, CAI: 1.40 Nm/kg and control: 1.73 Nm/kg). There were no differences in sEMG amplitudes between the groups or muscles ( P > .05). Force measures correlated with both muscles' sEMG amplitudes in the healthy group (neutral peroneus longus: r = 0.42, P = .03; plantarflexion peroneus longus: r = 0.56, P = .002; neutral peroneus brevis: r = 0.38, P = .05; plantarflexion peroneus longus: r = 0.40, P = .04), but not in the group with CAI ( P > .05). The group with CAI generated less force when compared to the control group during both testing positions. There was no selective activation of the peroneal muscles with testing in both positions, and force output and sEMG activity was only related in the healthy group. Clinicians should assess eversion strength and implement strength training exercises in different sagittal plane positions and evaluate for other

  20. Effect of whole-body vibration on lower-limb EMG activity in subjects with and without spinal cord injury

    PubMed Central

    Alizadeh-Meghrazi, Milad; Masani, Kei; Zariffa, José; Sayenko, Dimitry G.; Popovic, Milos R.; Craven, B. Catharine

    2014-01-01

    Objective Traumatic spinal cord injury (SCI) results in substantial reductions in lower extremity muscle mass and bone mineral density below the level of the lesion. Whole-body vibration (WBV) has been proposed as a means of counteracting or treating musculoskeletal degradation after chronic motor complete SCI. To ascertain how WBV might be used to augment muscle and bone mass, we investigated whether WBV could evoke lower extremity electromyography (EMG) activity in able-bodied individuals and individuals with SCI, and which vibration parameters produced the largest magnitude of effect. Methods Ten male subjects participated in the study, six able-bodied and four with chronic SCI. Two different manufacturers' vibration platforms (WAVE® and Juvent™) were evaluated. The effects of vibration amplitude (0.2, 0.6 or 1.2 mm), vibration frequency (25, 35, or 45 Hz), and subject posture (knee angle of 140°, 160°, or 180°) on lower extremity EMG activation were determined (not all combinations of parameters were possible on both platforms). A novel signal processing technique was proposed to estimate the power of the EMG waveform while minimizing interference and artifacts from the plate vibration. Results WBV can elicit EMG activity among subjects with chronic SCI, if appropriate vibration parameters are employed. The amplitude of vibration had the greatest influence on EMG activation, while the frequency of vibration had lesser but statistically significant impact on the measured lower extremity EMG activity. Conclusion These findings suggest that WBV with appropriate parameters may constitute a promising intervention to treat musculoskeletal degradation after chronic SCI. PMID:24986541

  1. The impact of shoulder abduction loading on EMG-based intention detection of hand opening and closing after stroke.

    PubMed

    Lan, Yiyun; Yao, Jun; Dewald, Julius P A

    2011-01-01

    Many stroke patients are subject to limited hand functions in the paretic arm due to a significant loss of Corticospinal Tract (CST) fibers. A possible solution for this problem is to classify surface Electromyography (EMG) signals generated by hand movements and uses that to implement Functional Electrical Stimulation (FES). However, EMG usually presents an abnormal muscle coactivation pattern shown as increased coupling between muscles within and/or across joints after stroke. The resulting Abnormal Muscle Synergies (AMS) could make the classification more difficult in individuals with stroke, especially when attempting to use the hand together with other joints in the paretic arm. Therefore, this study is aimed at identifying the impact of AMS following stroke on EMG pattern recognition between two hand movements. In an effort to achieve this goal, 7 chronic hemiparetic chronic stroke subjects were recruited and asked to perform hand opening and closing movements at their paretic arm while being either fully supported by a virtual table or loaded with 25% of subject's maximum shoulder abduction force. During the execution of motor tasks EMG signals from the wrist flexors and extensors were simultaneously acquired. Our results showed that increased synergy-induced activity at elbow flexors, induced by increasing shoulder abduction loading, deteriorated the performance of EMG pattern recognition for hand opening for those with a weak grasp strength and EMG activity. However, no such impact on hand closing has yet been observed possibly because finger/wrist flexion is facilitated by the shoulder abduction-induced flexion synergy.

  2. A motion-classification strategy based on sEMG-EEG signal combination for upper-limb amputees.

    PubMed

    Li, Xiangxin; Samuel, Oluwarotimi Williams; Zhang, Xu; Wang, Hui; Fang, Peng; Li, Guanglin

    2017-01-07

    Most of the modern motorized prostheses are controlled with the surface electromyography (sEMG) recorded on the residual muscles of amputated limbs. However, the residual muscles are usually limited, especially after above-elbow amputations, which would not provide enough sEMG for the control of prostheses with multiple degrees of freedom. Signal fusion is a possible approach to solve the problem of insufficient control commands, where some non-EMG signals are combined with sEMG signals to provide sufficient information for motion intension decoding. In this study, a motion-classification method that combines sEMG and electroencephalography (EEG) signals were proposed and investigated, in order to improve the control performance of upper-limb prostheses. Four transhumeral amputees without any form of neurological disease were recruited in the experiments. Five motion classes including hand-open, hand-close, wrist-pronation, wrist-supination, and no-movement were specified. During the motion performances, sEMG and EEG signals were simultaneously acquired from the skin surface and scalp of the amputees, respectively. The two types of signals were independently preprocessed and then combined as a parallel control input. Four time-domain features were extracted and fed into a classifier trained by the Linear Discriminant Analysis (LDA) algorithm for motion recognition. In addition, channel selections were performed by using the Sequential Forward Selection (SFS) algorithm to optimize the performance of the proposed method. The classification performance achieved by the fusion of sEMG and EEG signals was significantly better than that obtained by single signal source of either sEMG or EEG. An increment of more than 14% in classification accuracy was achieved when using a combination of 32-channel sEMG and 64-channel EEG. Furthermore, based on the SFS algorithm, two optimized electrode arrangements (10-channel sEMG + 10-channel EEG, 10-channel sEMG + 20-channel

  3. Lower extremity EMG-driven modeling of walking with automated adjustment of musculoskeletal geometry

    PubMed Central

    Meyer, Andrew J.; Patten, Carolynn

    2017-01-01

    Neuromusculoskeletal disorders affecting walking ability are often difficult to manage, in part due to limited understanding of how a patient’s lower extremity muscle excitations contribute to the patient’s lower extremity joint moments. To assist in the study of these disorders, researchers have developed electromyography (EMG) driven neuromusculoskeletal models utilizing scaled generic musculoskeletal geometry. While these models can predict individual muscle contributions to lower extremity joint moments during walking, the accuracy of the predictions can be hindered by errors in the scaled geometry. This study presents a novel EMG-driven modeling method that automatically adjusts surrogate representations of the patient’s musculoskeletal geometry to improve prediction of lower extremity joint moments during walking. In addition to commonly adjusted neuromusculoskeletal model parameters, the proposed method adjusts model parameters defining muscle-tendon lengths, velocities, and moment arms. We evaluated our EMG-driven modeling method using data collected from a high-functioning hemiparetic subject walking on an instrumented treadmill at speeds ranging from 0.4 to 0.8 m/s. EMG-driven model parameter values were calibrated to match inverse dynamic moments for five degrees of freedom in each leg while keeping musculoskeletal geometry close to that of an initial scaled musculoskeletal model. We found that our EMG-driven modeling method incorporating automated adjustment of musculoskeletal geometry predicted net joint moments during walking more accurately than did the same method without geometric adjustments. Geometric adjustments improved moment prediction errors by 25% on average and up to 52%, with the largest improvements occurring at the hip. Predicted adjustments to musculoskeletal geometry were comparable to errors reported in the literature between scaled generic geometric models and measurements made from imaging data. Our results demonstrate that

  4. Bayesian aggregation versus majority vote in the characterization of non-specific arm pain based on quantitative needle electromyography

    PubMed Central

    2010-01-01

    Background Methods for the calculation and application of quantitative electromyographic (EMG) statistics for the characterization of EMG data detected from forearm muscles of individuals with and without pain associated with repetitive strain injury are presented. Methods A classification procedure using a multi-stage application of Bayesian inference is presented that characterizes a set of motor unit potentials acquired using needle electromyography. The utility of this technique in characterizing EMG data obtained from both normal individuals and those presenting with symptoms of "non-specific arm pain" is explored and validated. The efficacy of the Bayesian technique is compared with simple voting methods. Results The aggregate Bayesian classifier presented is found to perform with accuracy equivalent to that of majority voting on the test data, with an overall accuracy greater than 0.85. Theoretical foundations of the technique are discussed, and are related to the observations found. Conclusions Aggregation of motor unit potential conditional probability distributions estimated using quantitative electromyographic analysis, may be successfully used to perform electrodiagnostic characterization of "non-specific arm pain." It is expected that these techniques will also be able to be applied to other types of electrodiagnostic data. PMID:20156353

  5. sEMG Sensor Using Polypyrrole-Coated Nonwoven Fabric Sheet for Practical Control of Prosthetic Hand

    PubMed Central

    Jiang, Yinlai; Togane, Masami; Lu, Baoliang; Yokoi, Hiroshi

    2017-01-01

    One of the greatest challenges of using a myoelectric prosthetic hand in daily life is to conveniently measure stable myoelectric signals. This study proposes a novel surface electromyography (sEMG) sensor using polypyrrole-coated nonwoven fabric sheet as electrodes (PPy electrodes) to allow people with disabilities to control prosthetic limbs. The PPy electrodes are sewn on an elastic band to guarantee close contact with the skin and thus reduce the contact electrical impedance between the electrodes and the skin. The sensor is highly customizable to fit the size and the shape of the stump so that people with disabilities can attach the sensor by themselves. The performance of the proposed sensor was investigated experimentally by comparing measurements of Ag/AgCl electrodes with electrolytic gel and the sEMG from the same muscle fibers. The high correlation coefficient (0.87) between the two types of sensors suggests the effectiveness of the proposed sensor. Another experiment of sEMG pattern recognition to control myoelectric prosthetic hands showed that the PPy electrodes are as effective as Ag/AgCl electrodes for measuring sEMG signals for practical myoelectric control. We also investigated the relation between the myoelectric signals' signal-to-noise ratio and the source impedances by simultaneously measuring the source impedances and the myoelectric signals with a switching circuit. The results showed that differences in both the norm and the phase of the source impedance greatly affect the common mode noise in the signal. PMID:28220058

  6. Real-time estimation of FES-induced joint torque with evoked EMG : Application to spinal cord injured patients.

    PubMed

    Li, Zhan; Guiraud, David; Andreu, David; Benoussaad, Mourad; Fattal, Charles; Hayashibe, Mitsuhiro

    2016-06-22

    Functional electrical stimulation (FES) is a neuroprosthetic technique for restoring lost motor function of spinal cord injured (SCI) patients and motor-impaired subjects by delivering short electrical pulses to their paralyzed muscles or motor nerves. FES induces action potentials respectively on muscles or nerves so that muscle activity can be characterized by the synchronous recruitment of motor units with its compound electromyography (EMG) signal is called M-wave. The recorded evoked EMG (eEMG) can be employed to predict the resultant joint torque, and modeling of FES-induced joint torque based on eEMG is an essential step to provide necessary prediction of the expected muscle response before achieving accurate joint torque control by FES. Previous works on FES-induced torque tracking issues were mainly based on offline analysis. However, toward personalized clinical rehabilitation applications, real-time FES systems are essentially required considering the subject-specific muscle responses against electrical stimulation. This paper proposes a wireless portable stimulator used for estimating/predicting joint torque based on real time processing of eEMG. Kalman filter and recurrent neural network (RNN) are embedded into the real-time FES system for identification and estimation. Prediction results on 3 able-bodied subjects and 3 SCI patients demonstrate promising performances. As estimators, both Kalman filter and RNN approaches show clinically feasible results on estimation/prediction of joint torque with eEMG signals only, moreover RNN requires less computational requirement. The proposed real-time FES system establishes a platform for estimating and assessing the mechanical output, the electromyographic recordings and associated models. It will contribute to open a new modality for personalized portable neuroprosthetic control toward consolidated personal healthcare for motor-impaired patients.

  7. Stretchable human-machine interface based on skin-conformal sEMG electrodes with self-similar geometry

    NASA Astrophysics Data System (ADS)

    Dong, Wentao; Zhu, Chen; Hu, Wei; Xiao, Lin; Huang, Yong'an

    2018-01-01

    Current stretchable surface electrodes have attracted increasing attention owing to their potential applications in biological signal monitoring, wearable human-machine interfaces (HMIs) and the Internet of Things. The paper proposed a stretchable HMI based on a surface electromyography (sEMG) electrode with a self-similar serpentine configuration. The sEMG electrode was transfer-printed onto the skin surface conformally to monitor biological signals, followed by signal classification and controlling of a mobile robot. Such electrodes can bear rather large deformation (such as >30%) under an appropriate areal coverage. The sEMG electrodes have been used to record electrophysiological signals from different parts of the body with sharp curvature, such as the index finger, back of the neck and face, and they exhibit great potential for HMI in the fields of robotics and healthcare. The electrodes placed onto the two wrists would generate two different signals with the fist clenched and loosened. It is classified to four kinds of signals with a combination of the gestures from the two wrists, that is, four control modes. Experiments demonstrated that the electrodes were successfully used as an HMI to control the motion of a mobile robot remotely. Project supported by the National Natural Science Foundation of China (Nos. 51635007, 91323303).

  8. Assessing the validity of surface electromyography for recording muscle activation patterns from serratus anterior.

    PubMed

    Hackett, Lucien; Reed, Darren; Halaki, Mark; Ginn, Karen A

    2014-04-01

    No direct evidence exists to support the validity of using surface electrodes to record muscle activity from serratus anterior, an important and commonly investigated shoulder muscle. The aims of this study were to determine the validity of examining muscle activation patterns in serratus anterior using surface electromyography and to determine whether intramuscular electromyography is representative of serratus anterior muscle activity. Seven asymptomatic subjects performed dynamic and isometric shoulder flexion, extension, abduction, adduction and dynamic bench press plus tests. Surface electrodes were placed over serratus anterior and around intramuscular electrodes in serratus anterior. Load was ramped during isometric tests from 0% to 100% maximum load and dynamic tests were performed at 70% maximum load. EMG signals were normalised using five standard maximum voluntary contraction tests. Surface electrodes significantly underestimated serratus anterior muscle activity compared with the intramuscular electrodes during dynamic flexion, dynamic abduction, isometric flexion, isometric abduction and bench press plus tests. All other test conditions showed no significant differences including the flexion normalisation test where maximum activation was recorded from both electrode types. Low correlation between signals was recorded using surface and intramuscular electrodes during concentric phases of dynamic abduction and flexion. It is not valid to use surface electromyography to assess muscle activation levels in serratus anterior during isometric exercises where the electrodes are not placed at the angle of testing and dynamic exercises. Intramuscular electrodes are as representative of the serratus anterior muscle activity as surface electrodes. Copyright © 2014 Elsevier Ltd. All rights reserved.

  9. Surface electromyography and ultrasound evaluation of pelvic floor muscles in hyperandrogenic women.

    PubMed

    Vassimon, Flávia Ignácio Antonio; Ferreira, Cristine Homsi Jorge; Martins, Wellington Paula; Ferriani, Rui Alberto; Batista, Roberta Leopoldino de Andrade; Bo, Kari

    2016-04-01

    High levels of androgens increase muscle mass. Due to the characteristics of hyperandrogenism in polycystic ovary syndrome (PCOS), it is plausible that women with PCOS may have increased pelvic floor muscle (PFM) thickness and neuromuscular activity levels compared with controls. The aim of this study was to assess PFM thickness and neuromuscular activity among hyperandrogenic women with PCOS and controls. This was an observational, cross-sectional, case-control study evaluating PFM by ultrasound (US) and surface electromyography (sEMG) in nonobese women with and without PCOS. Seventy-two women were divided into two groups: PCOS (n = 33) and controls (n = 39). PFM thickness during contraction was assessed by US (Vingmed CFM 800). Pelvic floor muscle activity was assessed by sEMG (MyoTrac Infinit) during contractions at different time lengths: quick, and 8 and 60 s. Descriptive analysis, analysis of variance (ANOVA), and Student's t test were used for statistical analyses. There were no significant differences in PFM sEMG activity between PCOS and controls in any of the contractions: quick contraction (73.23 mV/ 71.56 mV; p = 0.62), 8 s (55.77 mV/ 54.17 mV; p = 0.74), and 60 s (49.26 mV/ 47.32 mV; p = 0.68), respectively. There was no difference in PFM thickness during contractions evaluated by US between PCOS and controls (12.78 mm/ 13.43 mm; p =  .48). This study did not find statistically significant differences in pelvic floor muscle thickness or in muscle activity between PCOS women and controls.

  10. Emotional facial expressions during REM sleep dreams.

    PubMed

    Rivera-García, Ana P; López Ruiz, Irma E; Ramírez-Salado, Ignacio; González-Olvera, Jorge J; Ayala-Guerrero, Fructuoso; Jiménez-Anguiano, Anabel

    2018-06-04

    Although motor activity is actively inhibited during rapid eye movement (REM) sleep, specific activations of the facial mimetic musculature have been observed during this stage, which may be associated with greater emotional dream mentation. Nevertheless, no specific biomarker of emotional valence or arousal related to dream content has been identified to date. In order to explore the electromyographic (EMG) activity (voltage, number, density and duration) of the corrugator and zygomaticus major muscles during REM sleep and its association with emotional dream mentation, this study performed a series of experimental awakenings after observing EMG facial activations during REM sleep. The study was performed with 12 healthy female participants using an 8-hr nighttime sleep recording. Emotional tone was evaluated by five blinded judges and final valence and intensity scores were obtained. Emotions were mentioned in 80.4% of dream reports. The voltage, number, density and duration of facial muscle contractions were greater for the corrugator muscle than for the zygomaticus muscle, whereas high positive emotions predicted the number (R 2 0.601, p = 0.0001) and voltage (R 2 0.332, p = 0.005) of the zygomaticus. Our findings suggest that zygomaticus events were predictive of the experience of positive affect during REM sleep in healthy women. © 2018 European Sleep Research Society.

  11. [Evaluation of the electromyography activity of pelvic floor muscle during postural exercises using the Wii Fit Plus©. Analysis and perspectives in rehabilitation].

    PubMed

    Steenstrup, B; Giralte, F; Bakker, E; Grise, P

    2014-12-01

    The aim of this work was to evaluate the effect of postural awareness by using the Wii Fit Plus© on the quality of the baseline (automatic) activity of the pelvic floor muscles (PFM) measured by intravaginal surface electromyography (sEMG). Four healthy continent female subjects, all able to perform a voluntary contraction, undertook 2 sets of 3 various exercises offered by the software Wii Fit Plus© using the Wii balance board© (WBB): one set without any visual control and the second set with postural control and sEMG visual feedback. Simultaneously, we recorded the sEMG activity of the PFM. Mean baseline activity of PFM in standing position at start was 2.87 mV, at submaximal voluntary contraction the sEMG activity raised at a mean of 14.43 mV (7.87-21.89). In the first set of exercises on the WBB without any visual feedback, the automatic activity of the PFM increased from 2.87 mV to 8.75 mV (7.96-9.59). In the second set, with visual postural and sEMG control, mean baseline sEMG activity even raised at 11.39 mV (10.17-11.58). Among women able of a voluntary contraction of PFM, visualisation of posture with the help of the WBB and of sEMG activity of the PFM during static and dynamic Wii Fit Plus© activities, may improve the automatic activation of the PFMs. 4. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  12. Delayed facial nerve decompression for Bell's palsy.

    PubMed

    Kim, Sang Hoon; Jung, Junyang; Lee, Jong Ha; Byun, Jae Yong; Park, Moon Suh; Yeo, Seung Geun

    2016-07-01

    Incomplete recovery of facial motor function continues to be long-term sequelae in some patients with Bell's palsy. The purpose of this study was to investigate the efficacy of transmastoid facial nerve decompression after steroid and antiviral treatment in patients with late stage Bell's palsy. Twelve patients underwent surgical decompression for Bell's palsy 21-70 days after onset, whereas 22 patients were followed up after steroid and antiviral therapy without decompression. Surgical criteria included greater than 90 % degeneration on electroneuronography and no voluntary electromyography potentials. This study was a retrospective study of electrodiagnostic data and medical chart review between 2006 and 2013. Recovery from facial palsy was assessed using the House-Brackmann grading system. Final recovery rate did not differ significantly in the two groups; however, all patients in the decompression group recovered to at least House-Brackmann grade III at final follow-up. Although postoperative hearing threshold was increased in both groups, there was no significant between group difference in hearing threshold. Transmastoid decompression of the facial nerve in patients with severe late stage Bell's palsy at risk for a poor facial nerve outcome reduced severe complications of facial palsy with minimal morbidity.

  13. Circumferential urinary sphincter surface electromyography: A novel diagnostic method for intrinsic sphincter deficiency.

    PubMed

    Heesakkers, John; Gerretsen, Reza; Izeta, Ander; Sievert, Karl-Dietrich; Farag, Fawzy

    2016-02-01

    The diagnosis of intrinsic sphincter deficiency (ISD) in patients with stress urinary incontinence (SUI) is not well established. We explored the possibility of applying a new tool: minimally invasive circumferential sphincter surface electromyography (CSS-EMG) to assess the muscular integrity of the urethral sphincter in patients with SUI/ISD. CSS-EMG of the urethral sphincter and urodynamic studies were performed in 44 women with SUI. A urethral pressure profile (UPP) was measured in four directions. Maximal urethral closure pressure (MUCP) <40 cm/H2 O or the presence of SUI without urethral hypermobility was used to define ISD. Twenty-one patients had urodynamic SUI, 23 had no SUI and 12 patients had ISD. The mean average rectified value (ARV) of the motor unit action potential (MUAP), an indicator of the strength of urethral rhabdosphincter, was estimated. ARV measured in the 12 o'clock quadrant during maximal contraction was the only CSS-EMG parameter that had significant predictive value for ISD. With an increase in the 12 o'clock ARV value, the likelihood of ISD decreases (Odds Ratio 0.36 95% confidence interval 0.67-0.92). In the ROC curve with ARV measured in the 12 o'clock quadrant during maximal contraction, the explained area was 0.794 (P = 0.02); implying that ARV measured at the 12 o'clock quadrant during maximal contraction was able to predict ISD significantly. Myogenic changes of the urethral sphincter that contribute to ISD can be assessed with CSS-EMG. This new concept for assessing the functionality of the female urethral sphincter may assist with better understanding of the pathophysiology, the diagnosis and the treatment of SUI. © 2014 Wiley Periodicals, Inc.

  14. Comparison of Antagonist Muscle Activity During Walking Between Total Knee Replacement and Control Subjects Using Unnormalized Electromyography.

    PubMed

    Lundberg, Hannah J; Rojas, Idubijes L; Foucher, Kharma C; Wimmer, Markus A

    2016-06-01

    Although satisfactory outcomes have been reported after total knee replacement (TKR), full recovery of muscle strength and physical function is rare. We developed a relative activation index (RAI) to compare leg muscle activity from unnormalized surface electromyography (sEMG) between TKR and control subjects. Nineteen TKR and 19 control subjects underwent gait analysis and sEMG. RAIs were calculated by dividing the average sEMG for 2 consecutive subphases of stance defined by the direction of the external sagittal plane moment (flexion or extension). RAIs and external moments indicate TKR subjects have less initial stance antagonist rectus femoris activity (P = .004), greater middle stance antagonist biceps femoris activity (P < .001), and less late stance agonist biceps femoris activity (P < .001) than control subjects. Individuals with TKR demonstrate increased flexor muscle activation during weight bearing, potentially contributing to altered gait patterns found during the stance phase of gait. The RAI helps detail whether decreased external moments correspond to less agonist or more antagonist muscle activity to determine true muscle activity differences between subject groups. Identifying the mechanisms underlying altered muscle function both before and after TKR is critical for developing rehabilitation strategies to address functional deficits and disability found in this patient population. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. Do Dynamic Compared to Static Facial Expressions of Happiness and Anger Reveal Enhanced Facial Mimicry?

    PubMed Central

    Rymarczyk, Krystyna; Żurawski, Łukasz; Jankowiak-Siuda, Kamila; Szatkowska, Iwona

    2016-01-01

    Facial mimicry is the spontaneous response to others’ facial expressions by mirroring or matching the interaction partner. Recent evidence suggested that mimicry may not be only an automatic reaction but could be dependent on many factors, including social context, type of task in which the participant is engaged, or stimulus properties (dynamic vs static presentation). In the present study, we investigated the impact of dynamic facial expression and sex differences on facial mimicry and judgment of emotional intensity. Electromyography recordings were recorded from the corrugator supercilii, zygomaticus major, and orbicularis oculi muscles during passive observation of static and dynamic images of happiness and anger. The ratings of the emotional intensity of facial expressions were also analysed. As predicted, dynamic expressions were rated as more intense than static ones. Compared to static images, dynamic displays of happiness also evoked stronger activity in the zygomaticus major and orbicularis oculi, suggesting that subjects experienced positive emotion. No muscles showed mimicry activity in response to angry faces. Moreover, we found that women exhibited greater zygomaticus major muscle activity in response to dynamic happiness stimuli than static stimuli. Our data support the hypothesis that people mimic positive emotions and confirm the importance of dynamic stimuli in some emotional processing. PMID:27390867

  16. Evaluating the Training Effects of Two Swallowing Rehabilitation Therapies Using Surface Electromyography--Chin Tuck Against Resistance (CTAR) Exercise and the Shaker Exercise.

    PubMed

    Sze, Wei Ping; Yoon, Wai Lam; Escoffier, Nicolas; Rickard Liow, Susan J

    2016-04-01

    In this study, the efficacy of two dysphagia interventions, the Chin Tuck against Resistance (CTAR) and Shaker exercises, were evaluated based on two principles in exercise science-muscle-specificity and training intensity. Both exercises were developed to strengthen the suprahyoid muscles, whose contractions facilitate the opening of the upper esophageal sphincter, thereby improving bolus transfer. Thirty-nine healthy adults performed two trials of both exercises in counter-balanced order. Surface electromyography (sEMG) recordings were simultaneously collected from suprahyoid muscle group and sternocleidomastoid muscle during the exercises. Converging results using sEMG amplitude analyses suggested that the CTAR was more specific in targeting the suprahyoid muscles than the Shaker exercise. Fatigue analyses on sEMG signals further indicated that the suprahyoid muscle group were equally or significantly fatigued (depending on metric), when participants carried out CTAR compared to the Shaker exercise. Importantly, unlike during Shaker exercise, the sternocleidomastoid muscles were significantly less activated and fatigued during CTAR. Lowering the chin against resistance is therefore sufficiently specific and intense to fatigue the suprahyoid muscles.

  17. Management of synkinesis and asymmetry in facial nerve palsy: a review article.

    PubMed

    Pourmomeny, Abbas Ali; Asadi, Sahar

    2014-10-01

    The important sequelae of facial nerve palsy are synkinesis, asymmetry, hypertension and contracture; all of which have psychosocial effects on patients. Synkinesis due to mal regeneration causes involuntary movements during a voluntary movement. Previous studies have advocated treatment using physiotherapy modalities alone or with exercise therapy, but no consensus exists on the optimal approach. Thus, this review summarizes clinical controlled studies in the management of synkinesis and asymmetry in facial nerve palsy. Case-controlled clinical studies of patients at the acute stage of injury were selected for this review article. Data were obtained from English-language databases from 1980 until mid-2013. Among 124 articles initially captured, six randomized controlled trials involving 269 patients were identified with appropriate inclusion criteria. The results of all these studies emphasized the benefit of exercise therapy. Four studies considered electromyogram (EMG) biofeedback to be effective through neuromuscular re-education. Synkinesis and inconsistency of facial muscles could be treated with educational exercise therapy. EMG biofeedback is a suitable tool for this exercise therapy.

  18. Continuous and simultaneous estimation of finger kinematics using inputs from an EMG-to-muscle activation model.

    PubMed

    Ngeo, Jimson G; Tamei, Tomoya; Shibata, Tomohiro

    2014-08-14

    Surface electromyography (EMG) signals are often used in many robot and rehabilitation applications because these reflect motor intentions of users very well. However, very few studies have focused on the accurate and proportional control of the human hand using EMG signals. Many have focused on discrete gesture classification and some have encountered inherent problems such as electro-mechanical delays (EMD). Here, we present a new method for estimating simultaneous and multiple finger kinematics from multi-channel surface EMG signals. In this study, surface EMG signals from the forearm and finger kinematic data were extracted from ten able-bodied subjects while they were tasked to do individual and simultaneous multiple finger flexion and extension movements in free space. Instead of using traditional time-domain features of EMG, an EMG-to-Muscle Activation model that parameterizes EMD was used and shown to give better estimation performance. A fast feed forward artificial neural network (ANN) and a nonparametric Gaussian Process (GP) regressor were both used and evaluated to estimate complex finger kinematics, with the latter rarely used in the other related literature. The estimation accuracies, in terms of mean correlation coefficient, were 0.85 ± 0.07, 0.78 ± 0.06 and 0.73 ± 0.04 for the metacarpophalangeal (MCP), proximal interphalangeal (PIP) and the distal interphalangeal (DIP) finger joint DOFs, respectively. The mean root-mean-square error in each individual DOF ranged from 5 to 15%. We show that estimation improved using the proposed muscle activation inputs compared to other features, and that using GP regression gave better estimation results when using fewer training samples. The proposed method provides a viable means of capturing the general trend of finger movements and shows a good way of estimating finger joint kinematics using a muscle activation model that parameterizes EMD. The results from this study demonstrates a potential control

  19. Humeral external rotation handling by using the Bobath concept approach affects trunk extensor muscles electromyography in children with cerebral palsy.

    PubMed

    Grazziotin Dos Santos, C; Pagnussat, Aline S; Simon, A S; Py, Rodrigo; Pinho, Alexandre Severo do; Wagner, Mário B

    2014-10-20

    This study aimed to investigate the electromyographic activity of cervical and trunk extensors muscles in children with cerebral palsy during two handlings according to the Bobath concept. A crossover trial involving 40 spastic diplegic children was conducted. Electromyography (EMG) was used to measure muscular activity at sitting position (SP), during shoulder internal rotation (IR) and shoulder external rotation (ER) handlings, which were performed using the elbow joint as key point of control. Muscle recordings were performed at the fourth cervical (C4) and at the tenth thoracic (T10) vertebral levels. The Gross Motor Function Classification System (GMFCS) was used to assess whether muscle activity would vary according to different levels of severity. Humeral ER handling induced an increase on EMG signal of trunk extensor muscles at the C4 (P=0.007) and T10 (P<0.001) vertebral levels. No significant effects were observed between SP and humeral IR handling at C4 level; However at T10 region, humeral IR handling induced an increase of EMG signal (P=0.019). Humeral ER resulted in an increase of EMG signal at both levels, suggesting increase of extensor muscle activation. Furthermore, the humeral ER handling caused different responses on EMG signal at T10 vertebra level, according to the GMFCS classification (P=0.017). In summary, an increase of EMG signal was observed during ER handling in both evaluated levels, suggesting an increase of muscle activation. These results indicate that humeral ER handling can be used for diplegic CP children rehabilitation to facilitate cervical and trunk extensor muscles activity in a GMFCS level-dependent manner. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Analysis of Muscle Contraction on Pottery Manufacturing Process Using Electromyography (EMG)

    NASA Astrophysics Data System (ADS)

    Soewardi, Hartomo; Azka Rahmayani, Amalia

    2016-01-01

    One of the most common problems in pottery manufacturing process is musculoskeletal disorders on workers. This disorder was caused by uncomfortable posture where the workers sit on the floor with one leg was folded and another was twisted for long duration. Back, waist, buttock, and right knee frequently experience the disorders. The objective of this research is to investigate the muscle contraction at such body part of workers in manufacturing process of pottery. Electromyography is used to investigate the muscle contraction based on the median frequency signal. Focus measurements is conducted on four muscles types. They are lower interscapular muscle on the right and left side, dorsal lumbar muscle, and lateral hamstring muscle. Statistical analysis is conducted to test differences of muscle contraction between female and male. The result of this research showed that the muscle which reached the highest contraction is dorsal lumbar muscle with the average of median frequency is 51,84 Hz. Then followed by lower interscapular muscle on the left side with the average of median frequency is 31,30 hz, lower interscapular muscle on the right side average of median frequency is 31,24 Hz, and lateral hamstring muscle average of median frequency is 21,77 Hz. Based on the statistic analysis result, there were no differences between male and female on left and right lower interscapular muscle and dorsal lumbar muscle but there were differences on lateral hamstring muscle with the significance level is 5%. Besides that, there were differences for all combination muscle types with the level of significance is 5%.

  1. Social consequences of subclinical negative symptoms: An EMG study of facial expressions within a social interaction.

    PubMed

    Riehle, Marcel; Lincoln, Tania M

    2017-06-01

    The negative symptoms of schizophrenia are related to lower social functioning even in non-clinical samples, but little is known about the distinct social consequences of motivational and expressive negative symptoms. In this study we focused on expressive negative symptoms and examined how these symptoms and varying degrees of pro-social facial expressiveness (smiling and mimicry of smiling) relate to the social evaluations by face-to-face interaction partners and to social support. We examined 30 dyadic interactions within a sample of non-clinical participants (N = 60) who were rated on motivational and expressive negative symptoms with the Clinical Assessment Interview for Negative Symptoms (CAINS). We collected data on both interaction partners' smiling-muscle (zygomaticus major) activation simultaneously with electromyography and assessed the general amount of smiling and the synchrony of smiling muscle activations between interaction partners (mimicry of smiling). Interaction partners rated their willingness for future interactions with each other after the interactions. Interaction partners of participants scoring higher on expressive negative symptoms expressed less willingness for future interactions with these participants (r = -0.37; p = 0.01). Smiling behavior was negatively related to expressive negative symptoms but also explained by motivational negative symptoms. Mimicry of smiling and both negative symptom domains were also associated with participants' satisfaction with their social support network. Non-clinical sample with (relatively) low levels of symptoms. Expressive negative symptoms have tangible negative interpersonal consequences and directly relate to diminished pro-social behavior and social support, even in non-clinical samples. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Quantitative electromyography in ambulatory boys with Duchenne muscular dystrophy.

    PubMed

    Verma, Sumit; Lin, Jenny; Travers, Curtis; McCracken, Courtney; Shah, Durga

    2017-12-01

    This study's objective was to evaluate quantitative electromyography (QEMG) using multiple-motor-unit (multi-MUP) analysis in Duchenne muscular dystrophy (DMD). Ambulatory DMD boys, aged 5-15 years, were evaluated with QEMG at 6-month intervals over 14 months. EMG was performed in the right biceps brachii (BB) and tibialis anterior (TA) muscles. Normative QEMG data were obtained from age-matched healthy boys. Wilcoxon signed-rank tests were performed. Eighteen DMD subjects were enrolled, with a median age of 7 (interquartile range 7-10) years. Six-month evaluations were performed on 14 subjects. QEMG showed significantly abnormal mean MUP duration in BB and TA muscles, with no significant change over 6 months. QEMG is a sensitive electrophysiological marker of myopathy in DMD. Preliminary data do not reflect a significant change in MUP parameters over a 6-month interval; long-term follow-up QEMG studies are needed to understand its role as a biomarker for disease progression. Muscle Nerve 56: 1361-1364, 2017. © 2017 Wiley Periodicals, Inc.

  3. Wrist Rehabilitation Assisted by an Electromyography-Driven Neuromuscular Electrical Stimulation Robot After Stroke.

    PubMed

    Hu, Xiao-Ling; Tong, Raymond Kai-yu; Ho, Newmen S K; Xue, Jing-jing; Rong, Wei; Li, Leonard S W

    2015-09-01

    Augmented physical training with assistance from robot and neuromuscular electrical stimulation (NMES) may introduce intensive motor improvement in chronic stroke. To compare the rehabilitation effectiveness achieved by NMES robot-assisted wrist training and that by robot-assisted training. This study was a single-blinded randomized controlled trial with a 3-month follow-up. Twenty-six hemiplegic subjects with chronic stroke were randomly assigned to receive 20-session wrist training with an electromyography (EMG)-driven NMES robot (NMES robot group, n = 11) and with an EMG-driven robot (robot group, n = 15), completed within 7 consecutive weeks. Clinical scores, Fugl-Meyer Assessment (FMA), Modified Ashworth Score (MAS), and Action Research Arm Test (ARAT) were used to evaluate the training effects before and after the training, as well as 3 months later. An EMG parameter, muscle co-contraction index, was also applied to investigate the session-by-session variation in muscular coordination patterns during the training. The improvement in FMA (shoulder/elbow, wrist/hand) obtained in the NMES robot group was more significant than the robot group (P < .05). Significant improvement in ARAT was achieved in the NMES robot group (P < .05) but absent in the robot group. NMES robot-assisted training showed better performance in releasing muscle co-contraction than the robot-assisted across the training sessions (P < .05). The NMES robot-assisted wrist training was more effective than the pure robot. The additional NMES application in the treatment could bring more improvements in the distal motor functions and faster rehabilitation progress. © The Author(s) 2014.

  4. Detection of driving fatigue by using noncontact EMG and ECG signals measurement system.

    PubMed

    Fu, Rongrong; Wang, Hong

    2014-05-01

    Driver fatigue can be detected by constructing a discriminant mode using some features obtained from physiological signals. There exist two major challenges of this kind of methods. One is how to collect physiological signals from subjects while they are driving without any interruption. The other is to find features of physiological signals that are of corresponding change with the loss of attention caused by driver fatigue. Driving fatigue is detected based on the study of surface electromyography (EMG) and electrocardiograph (ECG) during the driving period. The noncontact data acquisition system was used to collect physiological signals from the biceps femoris of each subject to tackle the first challenge. Fast independent component analysis (FastICA) and digital filter were utilized to process the original signals. Based on the statistical analysis results given by Kolmogorov-Smirnov Z test, the peak factor of EMG (p < 0.001) and the maximum of the cross-relation curve of EMG and ECG (p < 0.001) were selected as the combined characteristic to detect fatigue of drivers. The discriminant criterion of fatigue was obtained from the training samples by using Mahalanobis distance, and then the average classification accuracy was given by 10-fold cross-validation. The results showed that the method proposed in this paper can give well performance in distinguishing the normal state and fatigue state. The noncontact, onboard vehicle drivers' fatigue detection system was developed to reduce fatigue-related risks.

  5. Motor unit number estimation based on high-density surface electromyography decomposition.

    PubMed

    Peng, Yun; He, Jinbao; Yao, Bo; Li, Sheng; Zhou, Ping; Zhang, Yingchun

    2016-09-01

    To advance the motor unit number estimation (MUNE) technique using high density surface electromyography (EMG) decomposition. The K-means clustering convolution kernel compensation algorithm was employed to detect the single motor unit potentials (SMUPs) from high-density surface EMG recordings of the biceps brachii muscles in eight healthy subjects. Contraction forces were controlled at 10%, 20% and 30% of the maximal voluntary contraction (MVC). Achieved MUNE results and the representativeness of the SMUP pools were evaluated using a high-density weighted-average method. Mean numbers of motor units were estimated as 288±132, 155±87, 107±99 and 132±61 by using the developed new MUNE at 10%, 20%, 30% and 10-30% MVCs, respectively. Over 20 SMUPs were obtained at each contraction level, and the mean residual variances were lower than 10%. The new MUNE method allows a convenient and non-invasive collection of a large size of SMUP pool with great representativeness. It provides a useful tool for estimating the motor unit number of proximal muscles. The present new MUNE method successfully avoids the use of intramuscular electrodes or multiple electrical stimuli which is required in currently available MUNE techniques; as such the new MUNE method can minimize patient discomfort for MUNE tests. Copyright © 2016 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  6. Effects of the antigravitary modification of the myotension of asset (MAGMA) therapy on myogenic cranio-cervical-mandibular dysfunction: a longitudinal surface electromyography analysis.

    PubMed

    D'Attilio, Michele; Di Meo, Silvio; Perinetti, Giuseppe; Filippi, Maria Rita; Tecco, Simona; D'Alconzo, Francesco; Festa, Felice

    2003-01-01

    This study was aimed at evaluating the effects of a novel physiotherapy machine called MAGMA (AntiGravitary Modification of the Myotensions of Asset) on postural and masticatory muscles of subjects with myogenic cranio-cervical-mandibular dysfunction (CMD), by using surface electromyography (sEMG). Fifteen subjects, nine males and six females (mean age 27.6 years), with CMD were included in the study. The bilaterally monitored muscles were: masseter, anterior and posterior temporalis, digastric, posterior cervical, sternocleidomastoid, and upper and lower trapezius. All muscles were monitored at rest, with a second record of maximal voluntary clenching (MVC) for both the masseter and anterior temporalis. Patients were subjected to MAGMA therapy for one session/week of 30 min over ten weeks. The surface EMG activity was recorded twice, at the baseline and at the end of the therapy. After MAGMA therapy, the sEMG activity at rest of the monitored muscles was significantly better when compared to the baseline; the only exception was the anterior and posterior temporalis muscles which did not improve. On the contrary, with the MVC, all the monitored muscles (masseter and anterior temporalis) significantly improved their sEMG activity. Although more investigations are needed, these results indicate that the use of such antigravitary therapy can provide a tool for resolving myogenic CMD.

  7. An ICA-EBM-Based sEMG Classifier for Recognizing Lower Limb Movements in Individuals With and Without Knee Pathology.

    PubMed

    Naik, Ganesh R; Selvan, S Easter; Arjunan, Sridhar P; Acharyya, Amit; Kumar, Dinesh K; Ramanujam, Arvind; Nguyen, Hung T

    2018-03-01

    Surface electromyography (sEMG) data acquired during lower limb movements has the potential for investigating knee pathology. Nevertheless, a major challenge encountered with sEMG signals generated by lower limb movements is the intersubject variability, because the signals recorded from the leg or thigh muscles are contingent on the characteristics of a subject such as gait activity and muscle structure. In order to cope with this difficulty, we have designed a three-step classification scheme. First, the multichannel sEMG is decomposed into activities of the underlying sources by means of independent component analysis via entropy bound minimization. Next, a set of time-domain features, which would best discriminate various movements, are extracted from the source estimates. Finally, the feature selection is performed with the help of the Fisher score and a scree-plot-based statistical technique, prior to feeding the dimension-reduced features to the linear discriminant analysis. The investigation involves 11 healthy subjects and 11 individuals with knee pathology performing three different lower limb movements, namely, walking, sitting, and standing, which yielded an average classification accuracy of 96.1% and 86.2%, respectively. While the outcome of this study per se is very encouraging, with suitable improvement, the clinical application of such an sEMG-based pattern recognition system that distinguishes healthy and knee pathological subjects would be an attractive consequence.

  8. Asymmetry in stimulus and response conflict processing across the adult lifespan: ERP and EMG evidence☆

    PubMed Central

    Killikelly, Clare; Szűcs, Dénes

    2013-01-01

    Several studies have shown that conflict processing improves from childhood to adulthood and declines from adulthood to old age. However the neural mechanisms underlying this lifespan asymmetry were previously unexplored. We combined event-related potentials (ERPs) and electromyography (EMG) to examine lifespan changes in stimulus and response conflict processing using a modified Stroop task. We used a Stroop task that a priori dissociated stimulus and response conflict. Delayed P3b latency and increased amplitude revealed that middle age adults have a deficit in stimulus processing. Additionally a sustained P3a across frontal and central electrodes occurred only in middle age adults indicating the recruitment of frontal activity. Conversely, decreased lateralized readiness potential (LRP) amplitude and increased EMG activity in the incorrect hand in adolescents reveal protracted development of response processing into late adolescence. The N450, a measure of conflict processing, was found to be sensitive to both stimulus and response conflict. Altogether these results provide evidence for asymmetrical differences in stimulus and response conflict processing across adolescence, young adulthood and middle age. PMID:24134924

  9. Can triggered electromyography monitoring throughout retraction predict postoperative symptomatic neuropraxia after XLIF? Results from a prospective multicenter trial.

    PubMed

    Uribe, Juan S; Isaacs, Robert E; Youssef, Jim A; Khajavi, Kaveh; Balzer, Jeffrey R; Kanter, Adam S; Küelling, Fabrice A; Peterson, Mark D

    2015-04-01

    This multicenter study aims to evaluate the utility of triggered electromyography (t-EMG) recorded throughout psoas retraction during lateral transpsoas interbody fusion to predict postoperative changes in motor function. Three hundred and twenty-three patients undergoing L4-5 minimally invasive lateral interbody fusion from 21 sites were enrolled. Intraoperative data collection included initial t-EMG thresholds in response to posterior retractor blade stimulation and subsequent t-EMG threshold values collected every 5 min throughout retraction. Additional data collection included dimensions/duration of retraction as well as pre-and postoperative lower extremity neurologic exams. Prior to expanding the retractor, the lowestt-EMG threshold was identified posterior to the retractor in 94 % of cases. Postoperatively, 13 (4.5 %) patients had a new motor weakness that was consistent with symptomatic neuropraxia (SN) of lumbar plexus nerves on the approach side. There were no significant differences between patients with or without a corresponding postoperative SN with respect to initial posterior blade reading (p = 0.600), or retraction dimensions (p > 0.05). Retraction time was significantly longer in those patients with SN vs. those without (p = 0.031). Stepwise logistic regression showed a significant positive relationship between the presence of new postoperative SN and total retraction time (p < 0.001), as well as change in t-EMG thresholds over time (p < 0.001), although false positive rates (increased threshold in patients with no new SN) remained high regardless of the absolute increase in threshold used to define an alarm criteria. Prolonged retraction time and coincident increases in t-EMG thresholds are predictors of declining nerve integrity. Increasing t-EMG thresholds, while predictive of injury, were also observed in a large number of patients without iatrogenic injury, with a greater predictive value in cases with extended duration. In addition to a

  10. A frequency and pulse-width co-modulation strategy for transcutaneous neuromuscular electrical stimulation based on sEMG time-domain features

    NASA Astrophysics Data System (ADS)

    Zhou, Yu-Xuan; Wang, Hai-Peng; Bao, Xue-Liang; Lü, Xiao-Ying; Wang, Zhi-Gong

    2016-02-01

    Objective. Surface electromyography (sEMG) is often used as a control signal in neuromuscular electrical stimulation (NMES) systems to enhance the voluntary control and proprioceptive sensory feedback of paralyzed patients. Most sEMG-controlled NMES systems use the envelope of the sEMG signal to modulate the stimulation intensity (current amplitude or pulse width) with a constant frequency. The aims of this study were to develop a strategy that co-modulates frequency and pulse width based on features of the sEMG signal and to investigate the torque-reproduction performance and the level of fatigue resistance achieved with our strategy. Approach. We examined the relationships between wrist torque and two stimulation parameters (frequency and pulse width) and between wrist torque and two sEMG time-domain features (mean absolute value (MAV) and number of slope sign changes (NSS)) in eight healthy volunteers. By using wrist torque as an intermediate variable, customized and generalized transfer functions were constructed to convert the two features of the sEMG signal into the two stimulation parameters, thereby establishing a MAV/NSS dual-coding (MNDC) algorithm. Wrist torque reproduction performance was assessed by comparing the torque generated by the algorithms with that originally recorded during voluntary contractions. Muscle fatigue was assessed by measuring the decline percentage of the peak torque and by comparing the torque time integral of the response to test stimulation trains before and after fatigue sessions. Main Results. The MNDC approach could produce a wrist torque that closely matched the voluntary wrist torque. In addition, a smaller decay in the wrist torque was observed after the MNDC-coded fatigue stimulation was applied than after stimulation using pulse-width modulation alone. Significance. Compared with pulse-width modulation stimulation strategies that are based on sEMG detection, the MNDC strategy is more effective for both voluntary muscle

  11. Surface EMG and intra-socket force measurement to control a prosthetic device

    NASA Astrophysics Data System (ADS)

    Sanford, Joe; Patterson, Rita; Popa, Dan

    2015-06-01

    Surface electromyography (SEMG) has been shown to be a robust and reliable interaction method allowing for basic control of powered prosthetic devices. Research has shown a marked decrease in EMG-classification efficiency throughout activities of daily life due to socket shift and movement and fatigue as well as changes in degree of fit of the socket throughout the subject's lifetime. Users with the most severe levels of amputation require the most complex devices with the greatest number of degrees of freedom. Controlling complex dexterous devices with limited available inputs requires the addition of sensing and interaction modalities. However, the larger the amputation severity, the fewer viable SEMG sites are available as control inputs. Previous work reported the use of intra-socket pressure, as measured during wrist flexion and extension, and has shown that it is possible to control a powered prosthetic device with pressure sensors. In this paper, we present data correlations of SEMG data with intra-socket pressure data. Surface EMG sensors and force sensors were housed within a simulated prosthetic cuff fit to a healthy-limbed subject. EMG and intra-socket force data was collected from inside the cuff as a subject performed pre-defined grip motions with their dominant hand. Data fusion algorithms were explored and allowed a subject to use both intra-socket pressure and SEMG data as control inputs for a powered prosthetic device. This additional input modality allows for an improvement in input classification as well as information regarding socket fit through out activities of daily life.

  12. Two cases of childhood narcolepsy mimicking epileptic seizures in video-EEG/EMG.

    PubMed

    Yanagishita, Tomoe; Ito, Susumu; Ohtani, Yui; Eto, Kaoru; Kanbayashi, Takashi; Oguni, Hirokazu; Nagata, Satoru

    2018-06-06

    Narcolepsy is characterized by excessive sleepiness, hypnagogic hallucinations, and sleep paralysis, and can occur with or without cataplexy. Here, we report two children with narcolepsy presenting with cataplexy mimicking epileptic seizures as determined by long-term video-electroencephalography (EEG) and electromyography (EMG) monitoring. Case 1 was a 15-year-old girl presenting with recurrent episodes of "convulsions" and loss of consciousness, who was referred to our hospital with a diagnosis of epilepsy showing "convulsions" and "complex partial seizures". The long-term video-polygraph showed a clonic attack lasting for 15 s, which corresponded to 1-2 Hz with interruption of mentalis EMG discharges lasting for 70-300 ms without any EEG changes. Narcolepsy was suspected due to the attack induced by hearty laughs and the presence of sleep attacks, and confirmed by low orexin levels in cerebrospinal fluid (CSF). Case 2 was an 11-year-old girl presenting with recurrent episodes of myoclonic attacks simultaneously with dropping objects immediately after hearty laughs, in addition to sleep attacks, hypnagogic hallucinations, and sleep paralysis. The long-term video-polygraph showed a subtle attack, characterized by dropping chopsticks from her hand, which corresponded to an interruption of ongoing deltoid EMG discharges lasting 140 ms without any EEG changes. A diagnosis of narcolepsy was confirmed by the low orexin levels in CSF. These cases demonstrate that children with narcolepsy may have attacks of cataplexy that resemble clonic or myoclonic seizures. Copyright © 2018 The Japanese Society of Child Neurology. Published by Elsevier B.V. All rights reserved.

  13. Validity and feasibility of the EMG direct observation tool (EMG-DOT).

    PubMed

    Leep Hunderfund, Andrea N; Rubin, Devon I; Laughlin, Ruple S; Sorenson, Eric J; Watson, James C; Jones, Lyell K; Juul, Dorthea; Park, Yoon Soo

    2016-04-26

    To develop a new workplace-based EMG direct observation tool (EMG-DOT) and gather validity evidence supporting its use for assessing electrodiagnostic skills among postgraduate medical trainees. The EMG-DOT was developed by experts using an iterative process. Validity evidence from content, response process, internal structure, relations to other variables, and consequences of testing was collected during the 2013-2014 academic year. Of 3,412 studies performed by trainees during the study period, 299 (9%) were assessed using the EMG-DOT. Of these, 203 (68%) involved a physician rater and 96 (32%) involved a technician rater. The 14-item EMG-DOT had excellent internal-consistency reliability (Cronbach α 0.94). Correlations between individual items and criterion-referenced global ratings of performance ranged from 0.36 to 0.72 (all p < 0.001). Mean total scores increased from 70% to 80% over 4 months of the EMG rotation (p < 0.001) despite a corresponding significant increase in case complexity (0.21-0.74 on a 3-point rating scale; p < 0.001). Trainees reported that the observational assessment exercise improved their knowledge or skills in 82% of encounters (188/230) and that feedback generated by the EMG-DOT improved the quality of care provided to patients in 58% (133/230). Trainees were "satisfied" or "very satisfied" with the observational assessment exercise in 96% of encounters (234/243). This study provides validity evidence supporting the use of EMG-DOT scores to assess electrodiagnostic skills of residents and fellows. The EMG-DOT can be used to inform milestone-based assessments of trainee performance in neurology, child neurology, physical medicine and rehabilitation, neuromuscular, and clinical neurophysiology training programs. © 2016 American Academy of Neurology.

  14. Wireless sEMG-Based Body-Machine Interface for Assistive Technology Devices.

    PubMed

    Fall, Cheikh Latyr; Gagnon-Turcotte, Gabriel; Dube, Jean-Francois; Gagne, Jean Simon; Delisle, Yanick; Campeau-Lecours, Alexandre; Gosselin, Clement; Gosselin, Benoit

    2017-07-01

    Assistive technology (AT) tools and appliances are being more and more widely used and developed worldwide to improve the autonomy of people living with disabilities and ease the interaction with their environment. This paper describes an intuitive and wireless surface electromyography (sEMG) based body-machine interface for AT tools. Spinal cord injuries at C5-C8 levels affect patients' arms, forearms, hands, and fingers control. Thus, using classical AT control interfaces (keypads, joysticks, etc.) is often difficult or impossible. The proposed system reads the AT users' residual functional capacities through their sEMG activity, and converts them into appropriate commands using a threshold-based control algorithm. It has proven to be suitable as a control alternative for assistive devices and has been tested with the JACO arm, an articulated assistive device of which the vocation is to help people living with upper-body disabilities in their daily life activities. The wireless prototype, the architecture of which is based on a 3-channel sEMG measurement system and a 915-MHz wireless transceiver built around a low-power microcontroller, uses low-cost off-the-shelf commercial components. The embedded controller is compared with JACO's regular joystick-based interface, using combinations of forearm, pectoral, masseter, and trapeze muscles. The measured index of performance values is 0.88, 0.51, and 0.41 bits/s, respectively, for correlation coefficients with the Fitt's model of 0.75, 0.85, and 0.67. These results demonstrate that the proposed controller offers an attractive alternative to conventional interfaces, such as joystick devices, for upper-body disabled people using ATs such as JACO.

  15. A Subthreshold Digital Library Using a Dynamic-Threshold Metal-Oxide Semiconductor (DTMOS) and Transmission Gate Logic

    DTIC Science & Technology

    2014-09-01

    electrocardiography (ECG), electromyography (EMG), and electroencephalography (EEG) applications that operate using thermoelectrically generated energy...semiconductor ECG electrocardiography EEG electroencephalography EMG electromyography FY15 fiscal year 2015 IC integrated circuit MOSFETs

  16. Face to face: blocking facial mimicry can selectively impair recognition of emotional expressions.

    PubMed

    Oberman, Lindsay M; Winkielman, Piotr; Ramachandran, Vilayanur S

    2007-01-01

    People spontaneously mimic a variety of behaviors, including emotional facial expressions. Embodied cognition theories suggest that mimicry reflects internal simulation of perceived emotion in order to facilitate its understanding. If so, blocking facial mimicry should impair recognition of expressions, especially of emotions that are simulated using facial musculature. The current research tested this hypothesis using four expressions (happy, disgust, fear, and sad) and two mimicry-interfering manipulations (1) biting on a pen and (2) chewing gum, as well as two control conditions. Experiment 1 used electromyography over cheek, mouth, and nose regions. The bite manipulation consistently activated assessed muscles, whereas the chew manipulation activated muscles only intermittently. Further, expressing happiness generated most facial action. Experiment 2 found that the bite manipulation interfered most with recognition of happiness. These findings suggest that facial mimicry differentially contributes to recognition of specific facial expressions, thus allowing for more refined predictions from embodied cognition theories.

  17. Locomotor adaptation to a soleus EMG-controlled antagonistic exoskeleton.

    PubMed

    Gordon, Keith E; Kinnaird, Catherine R; Ferris, Daniel P

    2013-04-01

    Locomotor adaptation in humans is not well understood. To provide insight into the neural reorganization that occurs following a significant disruption to one's learned neuromuscular map relating a given motor command to its resulting muscular action, we tied the mechanical action of a robotic exoskeleton to the electromyography (EMG) profile of the soleus muscle during walking. The powered exoskeleton produced an ankle dorsiflexion torque proportional to soleus muscle recruitment thus limiting the soleus' plantar flexion torque capability. We hypothesized that neurologically intact subjects would alter muscle activation patterns in response to the antagonistic exoskeleton by decreasing soleus recruitment. Subjects practiced walking with the exoskeleton for two 30-min sessions. The initial response to the perturbation was to "fight" the resistive exoskeleton by increasing soleus activation. By the end of training, subjects had significantly reduced soleus recruitment resulting in a gait pattern with almost no ankle push-off. In addition, there was a trend for subjects to reduce gastrocnemius recruitment in proportion to the soleus even though only the soleus EMG was used to control the exoskeleton. The results from this study demonstrate the ability of the nervous system to recalibrate locomotor output in response to substantial changes in the mechanical output of the soleus muscle and associated sensory feedback. This study provides further evidence that the human locomotor system of intact individuals is highly flexible and able to adapt to achieve effective locomotion in response to a broad range of neuromuscular perturbations.

  18. Locomotor adaptation to a soleus EMG-controlled antagonistic exoskeleton

    PubMed Central

    Kinnaird, Catherine R.; Ferris, Daniel P.

    2013-01-01

    Locomotor adaptation in humans is not well understood. To provide insight into the neural reorganization that occurs following a significant disruption to one's learned neuromuscular map relating a given motor command to its resulting muscular action, we tied the mechanical action of a robotic exoskeleton to the electromyography (EMG) profile of the soleus muscle during walking. The powered exoskeleton produced an ankle dorsiflexion torque proportional to soleus muscle recruitment thus limiting the soleus' plantar flexion torque capability. We hypothesized that neurologically intact subjects would alter muscle activation patterns in response to the antagonistic exoskeleton by decreasing soleus recruitment. Subjects practiced walking with the exoskeleton for two 30-min sessions. The initial response to the perturbation was to “fight” the resistive exoskeleton by increasing soleus activation. By the end of training, subjects had significantly reduced soleus recruitment resulting in a gait pattern with almost no ankle push-off. In addition, there was a trend for subjects to reduce gastrocnemius recruitment in proportion to the soleus even though only the soleus EMG was used to control the exoskeleton. The results from this study demonstrate the ability of the nervous system to recalibrate locomotor output in response to substantial changes in the mechanical output of the soleus muscle and associated sensory feedback. This study provides further evidence that the human locomotor system of intact individuals is highly flexible and able to adapt to achieve effective locomotion in response to a broad range of neuromuscular perturbations. PMID:23307949

  19. Ultrasonography for the diagnosis of tendinitis and electromyography for the diagnosis of peripheral neuropathy and upper limb radiculopathy: rheumatologists' perspectives.

    PubMed

    Helfenstein, Milton; Ferreira, Mario Soares; Maia, Anna Beatriz Assad; Siena, César Augusto Fávaro; Techy, Antonio

    2013-01-01

    To ascertain the value ascribed by Brazilian rheumatologists to ultrasonography (US) for diagnosing tendinitis and to electromyography (EMG) for diagnosing peripheral neuropathy and upper limb radiculopathy. In total, 165 rheumatologists answered an anonymous survey (sent via the internet) concerning the two exams, with respect to the following characteristics: reliability, diagnostic accuracy, the importance and necessity of these tests for diagnostic The study revealed that most of the rheumatologists recognised that these exams are operator-dependent, that clinicians do not rely entirely on the results, that these exams are not mandatory for the diagnoses listed, and that professionals who perform these exams should be better trained to provide reliable results. The Brazilian rheumatologists believe the following: the results of these exams should be interpreted with caution and are not definitive for diagnosis; musculoskeletal US and EMG should be performed by trained professionals; and there must be better preparation of the professionals who perform these exams.

  20. Surface EMG characteristics of people with multiple sclerosis during static contractions of the knee extensors.

    PubMed

    Scott, Sasha M; Hughes, Adrienne R; Galloway, Stuart D R; Hunter, Angus M

    2011-01-01

    This study was designed to determine whether any alterations existed in surface electromyography (sEMG) in people with multiple sclerosis (MS) during isometric contractions of the knee extensors. Fifteen people with MS and 14 matched controls (mean ± SD age and body mass index 53·7 ± 10·5 versus 54·6 ± 9·6 years and 27·7 ± 6·1 versus 26·5 ± 4, respectively) completed 20%, 40%, 60% and 80% of their maximal voluntary contraction (MVC) of the knee extensors. sEMG was recorded from the vastus lateralis where muscle fibre conduction velocity (MFCV) and sEMG amplitude (RMS) were assessed. Body composition was determined using dual-energy X-ray absorptiometry and physical activity with the use of accelerometry. People with MS showed significantly (P<0·05) faster MFCV during MVC (6·6 ± 2·7 versus 4·7 ± 1·4 m s(-1) ) and all submaximal contractions, while RMS was significantly (P<0·05) less (0·11 ± 0·03 versus 0·24 ± 0·06 mV) in comparison with the controls. MVC along with specific thigh lean mass to torque, rate of force development and mean physical activity were significantly (P<0·01) less in PwMS. People with MS have elevated MFCV alongside reduced RMS during isometric contraction. This elevation in MFCV should be accounted for when interpreting sEMG from people with MS. © 2010 University of Stirling. Clinical physiology and Functional Imaging © 2010 Scandinavian Society of Clinical Physiology and Nuclear Medicine.

  1. Comparison of sEMG-Based Feature Extraction and Motion Classification Methods for Upper-Limb Movement

    PubMed Central

    Guo, Shuxiang; Pang, Muye; Gao, Baofeng; Hirata, Hideyuki; Ishihara, Hidenori

    2015-01-01

    The surface electromyography (sEMG) technique is proposed for muscle activation detection and intuitive control of prostheses or robot arms. Motion recognition is widely used to map sEMG signals to the target motions. One of the main factors preventing the implementation of this kind of method for real-time applications is the unsatisfactory motion recognition rate and time consumption. The purpose of this paper is to compare eight combinations of four feature extraction methods (Root Mean Square (RMS), Detrended Fluctuation Analysis (DFA), Weight Peaks (WP), and Muscular Model (MM)) and two classifiers (Neural Networks (NN) and Support Vector Machine (SVM)), for the task of mapping sEMG signals to eight upper-limb motions, to find out the relation between these methods and propose a proper combination to solve this issue. Seven subjects participated in the experiment and six muscles of the upper-limb were selected to record sEMG signals. The experimental results showed that NN classifier obtained the highest recognition accuracy rate (88.7%) during the training process while SVM performed better in real-time experiments (85.9%). For time consumption, SVM took less time than NN during the training process but needed more time for real-time computation. Among the four feature extraction methods, WP had the highest recognition rate for the training process (97.7%) while MM performed the best during real-time tests (94.3%). The combination of MM and NN is recommended for strict real-time applications while a combination of MM and SVM will be more suitable when time consumption is not a key requirement. PMID:25894941

  2. Muscle Performance Investigated With a Novel Smart Compression Garment Based on Pressure Sensor Force Myography and Its Validation Against EMG

    PubMed Central

    Belbasis, Aaron; Fuss, Franz Konstantin

    2018-01-01

    Muscle activity and fatigue performance parameters were obtained and compared between both a smart compression garment and the gold-standard, a surface electromyography (EMG) system during high-speed cycling in seven participants. The smart compression garment, based on force myography (FMG), comprised of integrated pressure sensors that were sandwiched between skin and garment, located on five thigh muscles. The muscle activity was assessed by means of crank cycle diagrams (polar plots) that displayed the muscle activity relative to the crank cycle. The fatigue was assessed by means of the median frequency of the power spectrum of the EMG signal; the fractal dimension (FD) of the EMG signal; and the FD of the pressure signal. The smart compression garment returned performance parameters (muscle activity and fatigue) comparable to the surface EMG. The major differences were that the EMG measured the electrical activity, whereas the pressure sensor measured the mechanical activity. As such, there was a phase shift between electrical and mechanical signals, with the electrical signals preceding the mechanical counterparts in most cases. This is specifically pronounced in high-speed cycling. The fatigue trend over the duration of the cycling exercise was clearly reflected in the fatigue parameters (FDs and median frequency) obtained from pressure and EMG signals. The fatigue parameter of the pressure signal (FD) showed a higher time dependency (R2 = 0.84) compared to the EMG signal. This reflects that the pressure signal puts more emphasis on the fatigue as a function of time rather than on the origin of fatigue (e.g., peripheral or central fatigue). In light of the high-speed activity results, caution should be exerted when using data obtained from EMG for biomechanical models. In contrast to EMG data, activity data obtained from FMG are considered more appropriate and accurate as an input for biomechanical modeling as they truly reflect the mechanical muscle

  3. Muscle Performance Investigated With a Novel Smart Compression Garment Based on Pressure Sensor Force Myography and Its Validation Against EMG.

    PubMed

    Belbasis, Aaron; Fuss, Franz Konstantin

    2018-01-01

    Muscle activity and fatigue performance parameters were obtained and compared between both a smart compression garment and the gold-standard, a surface electromyography (EMG) system during high-speed cycling in seven participants. The smart compression garment, based on force myography (FMG), comprised of integrated pressure sensors that were sandwiched between skin and garment, located on five thigh muscles. The muscle activity was assessed by means of crank cycle diagrams (polar plots) that displayed the muscle activity relative to the crank cycle. The fatigue was assessed by means of the median frequency of the power spectrum of the EMG signal; the fractal dimension (FD) of the EMG signal; and the FD of the pressure signal. The smart compression garment returned performance parameters (muscle activity and fatigue) comparable to the surface EMG. The major differences were that the EMG measured the electrical activity, whereas the pressure sensor measured the mechanical activity. As such, there was a phase shift between electrical and mechanical signals, with the electrical signals preceding the mechanical counterparts in most cases. This is specifically pronounced in high-speed cycling. The fatigue trend over the duration of the cycling exercise was clearly reflected in the fatigue parameters (FDs and median frequency) obtained from pressure and EMG signals. The fatigue parameter of the pressure signal (FD) showed a higher time dependency ( R 2 = 0.84) compared to the EMG signal. This reflects that the pressure signal puts more emphasis on the fatigue as a function of time rather than on the origin of fatigue (e.g., peripheral or central fatigue). In light of the high-speed activity results, caution should be exerted when using data obtained from EMG for biomechanical models. In contrast to EMG data, activity data obtained from FMG are considered more appropriate and accurate as an input for biomechanical modeling as they truly reflect the mechanical muscle

  4. Choosing the best rehabilitation treatment for Bell's palsy.

    PubMed

    Dalla Toffola, E; Tinelli, C; Lozza, A; Bejor, M; Pavese, C; Degli Agosti, I; Petrucci, L

    2012-12-01

    It is useful to perform neurophysiologic electromyography and electroneurography (EMG/ENG) on patients with peripheral facial palsy during the acute phase of paralysis in order to assess the severity of their nerve lesion and thus plan rehabilitation treatment and evaluate its results. To evaluate the motor recovery of patients with Bell's palsy with respect to the severity of their neurological lesion and to compare the results of two different rehabilitation treatments, with electromyographic biofeedback (EMG-BFB) and mirror visual biofeedback (mirror-BFB), in patients with Bell's palsy and neurophysiologic pattern of axonotmesis. Cohort study on retrospective clinical records. 102 patients with Bell's facial palsy were clinically assessed according to the House scale both during the acute phase of paralysis and 12 months after onset. All patients underwent EMG/ENG examination 3-4 weeks after the onset of paralysis; 29 patients had an EMG pattern of neurapraxia and were not given rehabilitation treatment; 73 patients who presented with signs of denervation had an EMG pattern of axonotmesis. The group, which was homogenous in terms of lesion severity, was divided into two parts: 38 patients were treated with electromyographic biofeedback (EMG-BFB) and 35 were treated with mirror visual feedback (mirror-BFB). All 29 patients with neurapraxia made a full spontaneous recovery; Although the 73 patients with axonotmesis received different types of rehabilitation treatment, they obtained similar results regarding quality of recovery, development of synkinesis, rehabilitation timing and resources used. Rehabilitation treatment is not necessary for patients with neurapraxia. The two biofeedback methods used to treat patients with axonotmesis resulted in similar rehabilitation outcomes.

  5. Hypoglossal-facial-jump-anastomosis without an interposition nerve graft.

    PubMed

    Beutner, Dirk; Luers, Jan C; Grosheva, Maria

    2013-10-01

    The hypoglossal-facial-anastomosis is the most often applied procedure for the reanimation of a long lasting peripheral facial nerve paralysis. The use of an interposition graft and its end-to-side anastomosis to the hypoglossal nerve allows the preservation of the tongue function and also requires two anastomosis sites and a free second donor nerve. We describe the modified technique of the hypoglossal-facial-jump-anastomosis without an interposition and present the first results. Retrospective case study. We performed the facial nerve reconstruction in five patients. The indication for the surgery was a long-standing facial paralysis with preserved portion distal to geniculate ganglion, absent voluntary activity in the needle facial electromyography, and an intact bilateral hypoglossal nerve. Following mastoidectomy, the facial nerve was mobilized in the fallopian canal down to its bifurcation in the parotid gland and cut in its tympanic portion distal to the lesion. Then, a tensionless end-to-side suture to the hypoglossal nerve was performed. The facial function was monitored up to 16 months postoperatively. The reconstruction technique succeeded in all patients: The facial function improved within the average time period of 10 months to the House-Brackmann score 3. This modified technique of the hypoglossal-facial reanimation is a valid method with good clinical results, especially in cases of a preserved intramastoidal facial nerve. Level 4. Copyright © 2013 The American Laryngological, Rhinological and Otological Society, Inc.

  6. A novel estimating method for steering efficiency of the driver with electromyography signals

    NASA Astrophysics Data System (ADS)

    Liu, Yahui; Ji, Xuewu; Hayama, Ryouhei; Mizuno, Takahiro

    2014-05-01

    The existing research of steering efficiency mainly focuses on the mechanism efficiency of steering system, aiming at designing and optimizing the mechanism of steering system. In the development of assist steering system especially the evaluation of its comfort, the steering efficiency of driver physiological output usually are not considered, because this physiological output is difficult to measure or to estimate, and the objective evaluation of steering comfort therefore cannot be conducted with movement efficiency perspective. In order to take a further step to the objective evaluation of steering comfort, an estimating method for the steering efficiency of the driver was developed based on the research of the relationship between the steering force and muscle activity. First, the steering forces in the steering wheel plane and the electromyography (EMG) signals of the primary muscles were measured. These primary muscles are the muscles in shoulder and upper arm which mainly produced the steering torque, and their functions in steering maneuver were identified previously. Next, based on the multiple regressions of the steering force and EMG signals, both the effective steering force and the total force capacity of driver in steering maneuver were calculated. Finally, the steering efficiency of driver was estimated by means of the estimated effective force and the total force capacity, which represented the information of driver physiological output of the primary muscles. This research develops a novel estimating method for driver steering efficiency of driver physiological output, including the estimation of both steering force and the force capacity of primary muscles with EMG signals, and will benefit to evaluate the steering comfort with an objective perspective.

  7. Quality-of-Life Outcomes Following Surface Electromyography Biofeedback as an Adjunct to Pelvic Floor Muscle Training for Urinary Incontinence: A Case Report

    PubMed Central

    Hill, Alexandra; Alappattu, Meryl

    2018-01-01

    Background A non-invasive treatment for urinary incontinence (UI) is surface electromyography (sEMG) biofeedback with pelvic floor muscle (PFM) training. A lack of consensus and evidence exists on the Quality of Life (QoL) outcomes following sEMG biofeedback using surface electrodes at the perineum compared to the more invasive intravaginal probe. This case report examines QoL using sEMG biofeedback at the perineum with PFM training for UI. Study Design Single subject case report Case Description The patient was a 61-year-old woman diagnosed with UI. Her chief complaints were nocturia, urine leakage with urgency, and urine leakage with sneezing and coughing. Physical therapy (PT) treatment focused on behavioral modification, PFM strengthening with and without sEMG biofeedback, and therapeutic exercises with PFM contractions. Outcomes At four weeks from baseline, the patient’s PFM strength increased from 2/5 to 4/5 based on the Modified Laycock Scale. Her PFM endurance contraction improved from two seconds to ten seconds. The International Continence Impact Questionnaire – Urinary Incontinence Short Form (ICIQ-UI SF) score decreased from 6 to 0, the Incontinence Impact Questionnaire – Short Form (IIQ-7) score decreased from 14.3 to 0, and the 3 Incontinence Questions (3IQ) responses did not change. Discussion The outcomes from this case report demonstrate a brief course of PT treatment consisting of perineal sEMG biofeedback in conjunction with PFM training demonstrated clinically meaningful improvements in incontinence-related QoL, in addition to improvements in motor function in a woman with mixed UI and nocturia. PMID:29375282

  8. Quality-of-Life Outcomes Following Surface Electromyography Biofeedback as an Adjunct to Pelvic Floor Muscle Training for Urinary Incontinence: A Case Report.

    PubMed

    Hill, Alexandra; Alappattu, Meryl

    2017-05-01

    A non-invasive treatment for urinary incontinence (UI) is surface electromyography (sEMG) biofeedback with pelvic floor muscle (PFM) training. A lack of consensus and evidence exists on the Quality of Life (QoL) outcomes following sEMG biofeedback using surface electrodes at the perineum compared to the more invasive intravaginal probe. This case report examines QoL using sEMG biofeedback at the perineum with PFM training for UI. Single subject case report. The patient was a 61-year-old woman diagnosed with UI. Her chief complaints were nocturia, urine leakage with urgency, and urine leakage with sneezing and coughing. Physical therapy (PT) treatment focused on behavioral modification, PFM strengthening with and without sEMG biofeedback, and therapeutic exercises with PFM contractions. At four weeks from baseline, the patient's PFM strength increased from 2/5 to 4/5 based on the Modified Laycock Scale. Her PFM endurance contraction improved from two seconds to ten seconds. The International Continence Impact Questionnaire - Urinary Incontinence Short Form (ICIQ-UI SF) score decreased from 6 to 0, the Incontinence Impact Questionnaire - Short Form (IIQ-7) score decreased from 14.3 to 0, and the 3 Incontinence Questions (3IQ) responses did not change. The outcomes from this case report demonstrate a brief course of PT treatment consisting of perineal sEMG biofeedback in conjunction with PFM training demonstrated clinically meaningful improvements in incontinence-related QoL, in addition to improvements in motor function in a woman with mixed UI and nocturia.

  9. Electromyography-controlled exoskeletal upper-limb-powered orthosis for exercise training after stroke.

    PubMed

    Stein, Joel; Narendran, Kailas; McBean, John; Krebs, Kathryn; Hughes, Richard

    2007-04-01

    Robot-assisted exercise shows promise as a means of providing exercise therapy for weakness that results from stroke or other neurological conditions. Exoskeletal or "wearable" robots can, in principle, provide therapeutic exercise and/or function as powered orthoses to help compensate for chronic weakness. We describe a novel electromyography (EMG)-controlled exoskeletal robotic brace for the elbow (the active joint brace) and the results of a pilot study conducted using this brace for exercise training in individuals with chronic hemiparesis after stroke. Eight stroke survivors with severe chronic hemiparesis were enrolled in this pilot study. One subject withdrew from the study because of scheduling conflicts. A second subject was unable to participate in the training protocol because of insufficient surface EMG activity to control the active joint brace. The six remaining subjects each underwent 18 hrs of exercise training using the device for a period of 6 wks. Outcome measures included the upper-extremity component of the Fugl-Meyer scale and the modified Ashworth scale of muscle hypertonicity. Analysis revealed that the mean upper-extremity component of the Fugl-Meyer scale increased from 15.5 (SD 3.88) to 19 (SD 3.95) (P = 0.04) at the conclusion of training for the six subjects who completed training. Combined (summated) modified Ashworth scale for the elbow flexors and extensors improved from 4.67 (+/-1.2 SD) to 2.33 (+/-0.653 SD) (P = 0.009) and improved for the entire upper limb as well. All subjects tolerated the device, and no complications occurred. EMG-controlled powered elbow orthoses can be successfully controlled by severely impaired hemiparetic stroke survivors. This technique shows promise as a new modality for assisted exercise training after stroke.

  10. Diaphragm Muscle Surface Electromyography in Patients Submitted to Liver Transplant and Eligible for Extubation.

    PubMed

    Duarte, R P; Sentanin, A C; da Silva, A M O; Tonella, R M; Duarte, G L; Ratti, L S R; Boin, I F S F

    2017-05-01

    Liver disease induces many organic and metabolic changes, leading to malnutrition and weight and muscular function loss. Surface electromyography is an easily applicable, noninvasive study, through which the magnitudes of the peaks on the charts depict voluntary muscle activity. To evaluate the diaphragmatic surface electromyography of postoperative liver transplantation subjects. Subjects were patients who underwent liver transplantation and extubation in the Clinical Hospital of State University of Campinas. Electromyography data were collected with support pressure of ≤10 cm H 2 O, Glasgow Coma Scale = 11, and minimum dosages of vasoactive drugs, and data were collected again 30 minutes after extubation. Signal collection was performed with sEMG System Brazil SAS1000V3 electromyograph and electrode stickers. Statistical analysis was performed using R software. The average time of surgery was 345.36 ± 125.62 minutes. Time from spontaneous mode until extubation was 417.14 ± 362.97 minutes. The RMS (root mean square) values of the right and left domes in spontaneous mode with minimal ventilation parameters were 26.68 ± 10.92 and 26.55 ± 10.53, respectively, and the RMS values after extubation were 31.93 ± 18.69 to 34.62 ± 13.55, for right and left domes. The last calculated pretransplant Model for End-stage Liver Disease score averaged 19.64 ± 8.41. There were significant differences between the RMS of the diaphragm domes under mechanical ventilation and after extubation, showing lower effectiveness of the diaphragm muscle against resistance, without the aid of positive pressure and the existing overload of the left dome. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. EMG normalization method based on grade 3 of manual muscle testing: Within- and between-day reliability of normalization tasks and application to gait analysis.

    PubMed

    Tabard-Fougère, Anne; Rose-Dulcina, Kevin; Pittet, Vincent; Dayer, Romain; Vuillerme, Nicolas; Armand, Stéphane

    2018-02-01

    Electromyography (EMG) is an important parameter in Clinical Gait Analysis (CGA), and is generally interpreted with timing of activation. EMG amplitude comparisons between individuals, muscles or days need normalization. There is no consensus on existing methods. The gold standard, maximum voluntary isometric contraction (MVIC), is not adapted to pathological populations because patients are often unable to perform an MVIC. The normalization method inspired by the isometric grade 3 of manual muscle testing (isoMMT3), which is the ability of a muscle to maintain a position against gravity, could be an interesting alternative. The aim of this study was to evaluate the within- and between-day reliability of the isoMMT3 EMG normalizing method during gait compared with the conventional MVIC method. Lower limb muscles EMG (gluteus medius, rectus femoris, tibialis anterior, semitendinosus) were recorded bilaterally in nine healthy participants (five males, aged 29.7±6.2years, BMI 22.7±3.3kgm -2 ) giving a total of 18 independent legs. Three repeated measurements of the isoMMT3 and MVIC exercises were performed with an EMG recording. EMG amplitude of the muscles during gait was normalized by these two methods. This protocol was repeated one week later. Within- and between-day reliability of normalization tasks were similar for isoMMT3 and MVIC methods. Within- and between-day reliability of gait EMG normalized by isoMMT3 was higher than with MVIC normalization. These results indicate that EMG normalization using isoMMT3 is a reliable method with no special equipment needed and will support CGA interpretation. The next step will be to evaluate this method in pathological populations. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Surface electromyography based muscle fatigue detection using high-resolution time-frequency methods and machine learning algorithms.

    PubMed

    Karthick, P A; Ghosh, Diptasree Maitra; Ramakrishnan, S

    2018-02-01

    Surface electromyography (sEMG) based muscle fatigue research is widely preferred in sports science and occupational/rehabilitation studies due to its noninvasiveness. However, these signals are complex, multicomponent and highly nonstationary with large inter-subject variations, particularly during dynamic contractions. Hence, time-frequency based machine learning methodologies can improve the design of automated system for these signals. In this work, the analysis based on high-resolution time-frequency methods, namely, Stockwell transform (S-transform), B-distribution (BD) and extended modified B-distribution (EMBD) are proposed to differentiate the dynamic muscle nonfatigue and fatigue conditions. The nonfatigue and fatigue segments of sEMG signals recorded from the biceps brachii of 52 healthy volunteers are preprocessed and subjected to S-transform, BD and EMBD. Twelve features are extracted from each method and prominent features are selected using genetic algorithm (GA) and binary particle swarm optimization (BPSO). Five machine learning algorithms, namely, naïve Bayes, support vector machine (SVM) of polynomial and radial basis kernel, random forest and rotation forests are used for the classification. The results show that all the proposed time-frequency distributions (TFDs) are able to show the nonstationary variations of sEMG signals. Most of the features exhibit statistically significant difference in the muscle fatigue and nonfatigue conditions. The maximum number of features (66%) is reduced by GA and BPSO for EMBD and BD-TFD respectively. The combination of EMBD- polynomial kernel based SVM is found to be most accurate (91% accuracy) in classifying the conditions with the features selected using GA. The proposed methods are found to be capable of handling the nonstationary and multicomponent variations of sEMG signals recorded in dynamic fatiguing contractions. Particularly, the combination of EMBD- polynomial kernel based SVM could be used to

  13. 3D-Ultrasonography for evaluation of facial muscles in patients with chronic facial palsy or defective healing: a pilot study.

    PubMed

    Volk, Gerd Fabian; Pohlmann, Martin; Finkensieper, Mira; Chalmers, Heather J; Guntinas-Lichius, Orlando

    2014-01-01

    While standardized methods are established to examine the pathway from motorcortex to the peripheral nerve in patients with facial palsy, a reliable method to evaluate the facial muscles in patients with long-term palsy for therapy planning is lacking. A 3D ultrasonographic (US) acquisition system driven by a motorized linear mover combined with conventional US probe was used to acquire 3D data sets of several facial muscles on both sides of the face in a healthy subject and seven patients with different types of unilateral degenerative facial nerve lesions. The US results were correlated to the duration of palsy and the electromyography results. Consistent 3D US based volumetry through bilateral comparison was feasible for parts of the frontalis muscle, orbicularis oculi muscle, depressor anguli oris muscle, depressor labii inferioris muscle, and mentalis muscle. With the exception of the frontal muscle, the facial muscles volumes were much smaller on the palsy side (minimum: 3% for the depressor labii inferior muscle) than on the healthy side in patients with severe facial nerve lesion. In contrast, the frontal muscles did not show a side difference. In the two patients with defective healing after spontaneous regeneration a decrease in muscle volume was not seen. Synkinesis and hyperkinesis was even more correlated to muscle hypertrophy on the palsy compared with the healthy side. 3D ultrasonography seems to be a promising tool for regional and quantitative evaluation of facial muscles in patients with facial palsy receiving a facial reconstructive surgery or conservative treatment.

  14. 3D-Ultrasonography for evaluation of facial muscles in patients with chronic facial palsy or defective healing: a pilot study

    PubMed Central

    2014-01-01

    Background While standardized methods are established to examine the pathway from motorcortex to the peripheral nerve in patients with facial palsy, a reliable method to evaluate the facial muscles in patients with long-term palsy for therapy planning is lacking. Methods A 3D ultrasonographic (US) acquisition system driven by a motorized linear mover combined with conventional US probe was used to acquire 3D data sets of several facial muscles on both sides of the face in a healthy subject and seven patients with different types of unilateral degenerative facial nerve lesions. Results The US results were correlated to the duration of palsy and the electromyography results. Consistent 3D US based volumetry through bilateral comparison was feasible for parts of the frontalis muscle, orbicularis oculi muscle, depressor anguli oris muscle, depressor labii inferioris muscle, and mentalis muscle. With the exception of the frontal muscle, the facial muscles volumes were much smaller on the palsy side (minimum: 3% for the depressor labii inferior muscle) than on the healthy side in patients with severe facial nerve lesion. In contrast, the frontal muscles did not show a side difference. In the two patients with defective healing after spontaneous regeneration a decrease in muscle volume was not seen. Synkinesis and hyperkinesis was even more correlated to muscle hypertrophy on the palsy compared with the healthy side. Conclusion 3D ultrasonography seems to be a promising tool for regional and quantitative evaluation of facial muscles in patients with facial palsy receiving a facial reconstructive surgery or conservative treatment. PMID:24782657

  15. EMG (Electromyography) (For Parents)

    MedlinePlus

    ... topic for: Parents Kids Teens ECG (Electrocardiogram) Muscular Dystrophy Bones, Muscles, and Joints EEG (Electroencephalogram) Getting an EKG (Video) Medical Tests and Procedures (Video Landing Page) EKG (Video) Medical Tests: What to Expect ... About Us Contact Us Partners Editorial ...

  16. Wanting and liking in dysphoria: Cardiovascular and facial EMG responses during incentive processing.

    PubMed

    Franzen, Jessica; Brinkmann, Kerstin

    2016-12-01

    Theories and research on depression point to reduced responsiveness during reward anticipation and in part also during punishment anticipation. They also suggest weaker affective responses to reward consumption and unchanged affective responses to punishment consumption. However, studies investigating incentive anticipation using effort mobilization and incentive consumption using facial expressions are scarce. The present studies tested reward and punishment responsiveness in a subclinically depressed sample, manipulating a monetary reward (Study 1) and a monetary punishment (Study 2). Effort mobilization was operationalized as cardiovascular reactivity, while facial expressions were measured by facial electromyographic reactivity. Compared to nondysphorics, dysphorics showed reduced pre-ejection period (PEP) reactivity and blunted self-reported wanting during reward anticipation but reduced PEP reactivity and normal self-reported wanting during punishment anticipation. Compared to nondysphorics, dysphorics showed reduced zygomaticus major muscle reactivity and blunted self-reported liking during reward consumption but normal corrugator supercilii muscle reactivity and normal self-reported disliking during punishment consumption. Copyright © 2016. Published by Elsevier B.V.

  17. A Hybrid FPGA-Based System for EEG- and EMG-Based Online Movement Prediction

    PubMed Central

    Wöhrle, Hendrik; Tabie, Marc; Kim, Su Kyoung; Kirchner, Frank; Kirchner, Elsa Andrea

    2017-01-01

    A current trend in the development of assistive devices for rehabilitation, for example exoskeletons or active orthoses, is to utilize physiological data to enhance their functionality and usability, for example by predicting the patient’s upcoming movements using electroencephalography (EEG) or electromyography (EMG). However, these modalities have different temporal properties and classification accuracies, which results in specific advantages and disadvantages. To use physiological data analysis in rehabilitation devices, the processing should be performed in real-time, guarantee close to natural movement onset support, provide high mobility, and should be performed by miniaturized systems that can be embedded into the rehabilitation device. We present a novel Field Programmable Gate Array (FPGA) -based system for real-time movement prediction using physiological data. Its parallel processing capabilities allows the combination of movement predictions based on EEG and EMG and additionally a P300 detection, which is likely evoked by instructions of the therapist. The system is evaluated in an offline and an online study with twelve healthy subjects in total. We show that it provides a high computational performance and significantly lower power consumption in comparison to a standard PC. Furthermore, despite the usage of fixed-point computations, the proposed system achieves a classification accuracy similar to systems with double precision floating-point precision. PMID:28671632

  18. A Hybrid FPGA-Based System for EEG- and EMG-Based Online Movement Prediction.

    PubMed

    Wöhrle, Hendrik; Tabie, Marc; Kim, Su Kyoung; Kirchner, Frank; Kirchner, Elsa Andrea

    2017-07-03

    A current trend in the development of assistive devices for rehabilitation, for example exoskeletons or active orthoses, is to utilize physiological data to enhance their functionality and usability, for example by predicting the patient's upcoming movements using electroencephalography (EEG) or electromyography (EMG). However, these modalities have different temporal properties and classification accuracies, which results in specific advantages and disadvantages. To use physiological data analysis in rehabilitation devices, the processing should be performed in real-time, guarantee close to natural movement onset support, provide high mobility, and should be performed by miniaturized systems that can be embedded into the rehabilitation device. We present a novel Field Programmable Gate Array (FPGA) -based system for real-time movement prediction using physiological data. Its parallel processing capabilities allows the combination of movement predictions based on EEG and EMG and additionally a P300 detection, which is likely evoked by instructions of the therapist. The system is evaluated in an offline and an online study with twelve healthy subjects in total. We show that it provides a high computational performance and significantly lower power consumption in comparison to a standard PC. Furthermore, despite the usage of fixed-point computations, the proposed system achieves a classification accuracy similar to systems with double precision floating-point precision.

  19. Paralyzed subject controls telepresence mobile robot using novel sEMG brain-computer interface: case study.

    PubMed

    Lyons, Kenneth R; Joshi, Sanjay S

    2013-06-01

    Here we demonstrate the use of a new singlesignal surface electromyography (sEMG) brain-computer interface (BCI) to control a mobile robot in a remote location. Previous work on this BCI has shown that users are able to perform cursor-to-target tasks in two-dimensional space using only a single sEMG signal by continuously modulating the signal power in two frequency bands. Using the cursor-to-target paradigm, targets are shown on the screen of a tablet computer so that the user can select them, commanding the robot to move in different directions for a fixed distance/angle. A Wifi-enabled camera transmits video from the robot's perspective, giving the user feedback about robot motion. Current results show a case study with a C3-C4 spinal cord injury (SCI) subject using a single auricularis posterior muscle site to navigate a simple obstacle course. Performance metrics for operation of the BCI as well as completion of the telerobotic command task are developed. It is anticipated that this noninvasive and mobile system will open communication opportunities for the severely paralyzed, possibly using only a single sensor.

  20. Simplifying the diagnosis of 4 common voiding conditions using uroflow/electromyography, electromyography lag time and voiding history.

    PubMed

    Van Batavia, Jason P; Combs, Andrew J; Hyun, Grace; Bayer, Agnes; Medina-Kreppein, Daisy; Schlussel, Richard N; Glassberg, Kenneth I

    2011-10-01

    Noninvasive uroflowmetry with simultaneous electromyography is useful to triage cases of lower urinary tract symptoms into 4 urodynamically defined conditions, especially when incorporating short and long electromyography lag times in the analysis. We determined the prevalence of these 4 conditions at a single referral institution and the usefulness of uroflowmetry with simultaneous electromyography and electromyography lag time to confirm the diagnosis, guide treatment and monitor response. We retrospectively reviewed the records of 100 consecutive normal children who presented with persistent lower urinary tract symptoms, underwent uroflowmetry with electromyography as part of the initial evaluation and were diagnosed with 1 of 4 conditions based on certain uroflowmetry/electromyography features. The conditions included 1) dysfunctional voiding--active pelvic floor electromyography during voiding with or without staccato flow, 2a) idiopathic detrusor overactivity disorder-A--a quiet pelvic floor during voiding and shortened lag time (less than 2 seconds), 2b) idiopathic detrusor overactivity disorder-B--a quiet pelvic floor with a normal lag time, 3) detrusor underutilization disorder--volitionally deferred voiding with expanded bladder capacity but a quiet pelvic floor, and 4) primary bladder neck dysfunction--prolonged lag time (greater than 6 seconds) and a depressed, right shifted uroflowmetry curve with a quiet pelvic floor during voiding. Treatment was tailored to the underlying condition in each patient. The group consisted of 50 males and 50 females with a mean age of 8 years (range 3 to 18). Dysfunctional voiding was more common in females (p <0.05) while idiopathic detrusor overactivity disorder-B and primary bladder neck dysfunction were more common in males (p <0.01). With treatment uroflowmetry parameters normalized for all types. Electromyography lag time increased in idiopathic detrusor overactivity disorder-A cases and decreased in primary bladder

  1. Time-varying surface electromyography topography as a prognostic tool for chronic low back pain rehabilitation.

    PubMed

    Hu, Yong; Kwok, Jerry Weilun; Tse, Jessica Yuk-Hang; Luk, Keith Dip-Kei

    2014-06-01

    Nonsurgical rehabilitation therapy is a commonly used strategy to treat chronic low back pain (LBP). The selection of the most appropriate therapeutic options is still a big challenge in clinical practices. Surface electromyography (sEMG) topography has been proposed to be an objective assessment of LBP rehabilitation. The quantitative analysis of dynamic sEMG would provide an objective tool of prognosis for LBP rehabilitation. To evaluate the prognostic value of quantitative sEMG topographic analysis and to verify the accuracy of the performance of proposed time-varying topographic parameters for identifying the patients who have better response toward the rehabilitation program. A retrospective study of consecutive patients. Thirty-eight patients with chronic nonspecific LBP and 43 healthy subjects. The accuracy of the time-varying quantitative sEMG topographic analysis for monitoring LBP rehabilitation progress was determined by calculating the corresponding receiver-operating characteristic (ROC) curves. Physiologic measure was the sEMG during lumbar flexion and extension. Patients who suffered from chronic nonspecific LBP without the history of back surgery and any medical conditions causing acute exacerbation of LBP during the clinical test were enlisted to perform the clinical test during the 12-week physiotherapy (PT) treatment. Low back pain patients were classified into two groups: "responding" and "nonresponding" based on the clinical assessment. The responding group referred to the LBP patients who began to recover after the PT treatment, whereas the nonresponding group referred to some LBP patients who did not recover or got worse after the treatment. The results of the time-varying analysis in the responding group were compared with those in the nonresponding group. In addition, the accuracy of the analysis was analyzed through ROC curves. The time-varying analysis showed discrepancies in the root-mean-square difference (RMSD) parameters between the

  2. The feasibility of sugammadex for general anesthesia and facial nerve monitoring in patients undergoing parotid surgery.

    PubMed

    Lu, I-Cheng; Chang, Pi-Ying; Su, Miao-Pei; Chen, Po-Nien; Chen, Hsiu-Ya; Chiang, Feng-Yu; Wu, Che-Wei

    2017-08-01

    The use of neuromuscular blocking agent (NMBA) during anesthesia may interfere with facial nerve monitoring (FNM) during parotid surgery. Sugammadex has been reported to be an effective and safe reversal of rocuronium-induced neuromuscular block (NMB) during surgery. This study investigated the feasibility and clinical effectiveness of sugammadex for NMB reversal during FNM in Parotid surgery. Fifty patients undergoing parotid surgery were randomized allocated into conventional anesthesia group (Group C, n = 25) and sugammadex group (Group S, n = 25). Group C did not receive any NMBA. Group S received rocuronium 0.6 mg/kg at anesthesia induction and sugammadex 2 mg/kg at skin incision. The intubating condition and influence on FNM evoked EMG results were compared between groups. The intubation condition showed significantly better in group S patients than C group patients (excellent in 96% v.s. 24%). In group S, rapid reverse of NMB was found and the twitch (%) recovered from 0 to >90% within 10 min. Positive and high EMG signals were obtained in all patients at the time point of initial facial nerve stimulation in both groups. There was no significant difference as comparing the EMG amplitudes detected at the time point of initial and final facial nerve stimulation in both groups. Implementation of sugammadex in anesthesia protocol is feasible and reliable for successful FNM during parotid surgery. Copyright © 2017. Published by Elsevier Taiwan.

  3. EMG-Torque Relation in Chronic Stroke: A Novel EMG Complexity Representation With a Linear Electrode Array.

    PubMed

    Zhang, Xu; Wang, Dongqing; Yu, Zaiyang; Chen, Xiang; Li, Sheng; Zhou, Ping

    2017-11-01

    This study examines the electromyogram (EMG)-torque relation for chronic stroke survivors using a novel EMG complexity representation. Ten stroke subjects performed a series of submaximal isometric elbow flexion tasks using their affected and contralateral arms, respectively, while a 20-channel linear electrode array was used to record surface EMG from the biceps brachii muscles. The sample entropy (SampEn) of surface EMG signals was calculated with both global and local tolerance schemes. A regression analysis was performed between SampEn of each channel's surface EMG and elbow flexion torque. It was found that a linear regression can be used to well describe the relation between surface EMG SampEn and the torque. Each channel's root mean square (RMS) amplitude of surface EMG signal in the different torque level was computed to determine the channel with the highest EMG amplitude. The slope of the regression (observed from the channel with the highest EMG amplitude) was smaller on the impaired side than on the nonimpaired side in 8 of the 10 subjects, regardless of the tolerance scheme (global or local) and the range of torques (full or matched range) used for comparison. The surface EMG signals from the channels above the estimated muscle innervation zones demonstrated significantly lower levels of complexity compared with other channels between innervation zones and muscle tendons. The study provides a novel point of view of the EMG-torque relation in the complexity domain, and reveals its alterations post stroke, which are associated with complex neural and muscular changes post stroke. The slope difference between channels with regard to innervation zones also confirms the relevance of electrode position in surface EMG analysis.

  4. Kinematic, kinetic and EMG analysis of four front crawl flip turn techniques.

    PubMed

    Pereira, Suzana Matheus; Ruschel, Caroline; Hubert, Marcel; Machado, Leandro; Roesler, Helio; Fernandes, Ricardo Jorge; Vilas-Boas, João Paulo

    2015-01-01

    This study aimed to analyse the kinematic, kinetic and electromyographic characteristics of four front crawl flip turn technique variants. The variants distinguished from each other by differences in body position (i.e., dorsal, lateral, ventral) during rolling, wall support, pushing and gliding phases. Seventeen highly trained swimmers (17.9 ± 3.2 years old) participated in interventional sessions and performed three trials of each variant, being monitored with a 3-D video system, a force platform and an electromyography (EMG) system. Studied variables: rolling time and distance, wall support time, push-off time, peak force and horizontal impulse at wall support and push-off, centre of mass horizontal velocity at the end of the push-off, gliding time, centre of mass depth, distance, average and final velocity during gliding, total turn time and electrical activity of Gastrocnemius Medialis, Tibialis Anterior, Biceps Femoris and Vastus Lateralis muscles. Depending on the variant, total turn time ranged from 2.37 ± 0.32 to 2.43 ± 0.33 s, push-off force from 1.86 ± 0.33 to 1.92 ± 0.26 BW and centre of mass velocity during gliding from 1.78 ± 0.21 to 1.94 ± 0.22 m · s(-1). The variants were not distinguishable in terms of kinematical, kinetic and EMG parameters during the rolling, wall support, pushing and gliding phases.

  5. EMG circuit design and AR analysis of EMG signs.

    PubMed

    Hardalaç, Firat; Canal, Rahmi

    2004-12-01

    In this study, electromyogram (EMG) circuit was designed and tested on 27 people. Autoregressive (AR) analysis of EMG signals recorded on the ulnar nerve region of the right hand in resting position was performed. AR method, especially in the calculation of the spectrums of stable signs, is used for frequency analysis of signs, which give frequency response as sharp peaks and valleys. In this study, as the result of AR method analysis of EMG signals frequency-time domain, frequency spectrum curves (histogram curves) were obtained. As the images belonging to these histograms were evaluated, fibrillation potential widths of the muscle fibers of the ulnar nerve region of the people (material of the study) were examined. According to the degeneration degrees of the motor nerves, nine people had myopathy, nine had neuropathy, and nine were normal.

  6. Improving robustness against electrode shift of high density EMG for myoelectric control through common spatial patterns.

    PubMed

    Pan, Lizhi; Zhang, Dingguo; Jiang, Ning; Sheng, Xinjun; Zhu, Xiangyang

    2015-12-02

    Most prosthetic myoelectric control studies have concentrated on low density (less than 16 electrodes, LD) electromyography (EMG) signals, due to its better clinical applicability and low computation complexity compared with high density (more than 16 electrodes, HD) EMG signals. Since HD EMG electrodes have been developed more conveniently to wear with respect to the previous versions recently, HD EMG signals become an alternative for myoelectric prostheses. The electrode shift, which may occur during repositioning or donning/doffing of the prosthetic socket, is one of the main reasons for degradation in classification accuracy (CA). HD EMG signals acquired from the forearm of the subjects were used for pattern recognition-based myoelectric control in this study. Multiclass common spatial patterns (CSP) with two types of schemes, namely one versus one (CSP-OvO) and one versus rest (CSP-OvR), were used for feature extraction to improve the robustness against electrode shift for myoelectric control. Shift transversal (ST1 and ST2) and longitudinal (SL1 and SL2) to the direction of the muscle fibers were taken into consideration. We tested nine intact-limb subjects for eleven hand and wrist motions. The CSP features (CSP-OvO and CSP-OvR) were compared with three commonly used features, namely time-domain (TD) features, time-domain autoregressive (TDAR) features and variogram (Variog) features. Compared with the TD features, the CSP features significantly improved the CA over 10 % in all shift configurations (ST1, ST2, SL1 and SL2). Compared with the TDAR features, a. the CSP-OvO feature significantly improved the average CA over 5 % in all shift configurations; b. the CSP-OvR feature significantly improved the average CA in shift configurations ST1, SL1 and SL2. Compared with the Variog features, the CSP features significantly improved the average CA in longitudinal shift configurations (SL1 and SL2). The results demonstrated that the CSP features significantly

  7. Hybrid fusion of linear, non-linear and spectral models for the dynamic modeling of sEMG and skeletal muscle force: an application to upper extremity amputation.

    PubMed

    Potluri, Chandrasekhar; Anugolu, Madhavi; Schoen, Marco P; Subbaram Naidu, D; Urfer, Alex; Chiu, Steve

    2013-11-01

    Estimating skeletal muscle (finger) forces using surface Electromyography (sEMG) signals poses many challenges. In general, the sEMG measurements are based on single sensor data. In this paper, two novel hybrid fusion techniques for estimating the skeletal muscle force from the sEMG array sensors are proposed. The sEMG signals are pre-processed using five different filters: Butterworth, Chebychev Type II, Exponential, Half-Gaussian and Wavelet transforms. Dynamic models are extracted from the acquired data using Nonlinear Wiener Hammerstein (NLWH) models and Spectral Analysis Frequency Dependent Resolution (SPAFDR) models based system identification techniques. A detailed comparison is provided for the proposed filters and models using 18 healthy subjects. Wavelet transforms give higher mean correlation of 72.6 ± 1.7 (mean ± SD) and 70.4 ± 1.5 (mean ± SD) for NLWH and SPAFDR models, respectively, when compared to the other filters used in this work. Experimental verification of the fusion based hybrid models with wavelet transform shows a 96% mean correlation and 3.9% mean relative error with a standard deviation of ± 1.3 and ± 0.9 respectively between the overall hybrid fusion algorithm estimated and the actual force for 18 test subjects' k-fold cross validation data. © 2013 Elsevier Ltd. All rights reserved.

  8. Identification and agreement of first turn point by mathematical analysis applied to heart rate, carbon dioxide output and electromyography.

    PubMed

    Zamunér, Antonio R; Catai, Aparecida M; Martins, Luiz E B; Sakabe, Daniel I; Da Silva, Ester

    2013-01-01

    The second heart rate (HR) turn point has been extensively studied, however there are few studies determining the first HR turn point. Also, the use of mathematical and statistical models for determining changes in dynamic characteristics of physiological variables during an incremental cardiopulmonary test has been suggested. To determine the first turn point by analysis of HR, surface electromyography (sEMG), and carbon dioxide output (VCO2) using two mathematical models and to compare the results to those of the visual method. Ten sedentary middle-aged men (53.9 ± 3.2 years old) were submitted to cardiopulmonary exercise testing on an electromagnetic cycle ergometer until exhaustion. Ventilatory variables, HR, and sEMG of the vastus lateralis were obtained in real time. Three methods were used to determine the first turn point: 1) visual analysis based on loss of parallelism between VCO2 and oxygen uptake (VO2); 2) the linear-linear model, based on fitting the curves to the set of VCO2 data (Lin-LinVCO2); 3) a bi-segmental linear regression of Hinkley's algorithm applied to HR (HMM-HR), VCO2 (HMM-VCO2), and sEMG data (HMM-RMS). There were no differences between workload, HR, and ventilatory variable values at the first ventilatory turn point as determined by the five studied parameters (p>0.05). The Bland-Altman plot showed an even distribution of the visual analysis method with Lin-LinVCO2, HMM-HR, HMM-VCO2, and HMM-RMS. The proposed mathematical models were effective in determining the first turn point since they detected the linear pattern change and the deflection point of VCO2, HR responses, and sEMG.

  9. Identification and agreement of first turn point by mathematical analysis applied to heart rate, carbon dioxide output and electromyography

    PubMed Central

    Zamunér, Antonio R.; Catai, Aparecida M.; Martins, Luiz E. B.; Sakabe, Daniel I.; Silva, Ester Da

    2013-01-01

    Background The second heart rate (HR) turn point has been extensively studied, however there are few studies determining the first HR turn point. Also, the use of mathematical and statistical models for determining changes in dynamic characteristics of physiological variables during an incremental cardiopulmonary test has been suggested. Objectives To determine the first turn point by analysis of HR, surface electromyography (sEMG), and carbon dioxide output () using two mathematical models and to compare the results to those of the visual method. Method Ten sedentary middle-aged men (53.9±3.2 years old) were submitted to cardiopulmonary exercise testing on an electromagnetic cycle ergometer until exhaustion. Ventilatory variables, HR, and sEMG of the vastus lateralis were obtained in real time. Three methods were used to determine the first turn point: 1) visual analysis based on loss of parallelism between and oxygen uptake (); 2) the linear-linear model, based on fitting the curves to the set of data (Lin-Lin ); 3) a bi-segmental linear regression of Hinkley' s algorithm applied to HR (HMM-HR), (HMM- ), and sEMG data (HMM-RMS). Results There were no differences between workload, HR, and ventilatory variable values at the first ventilatory turn point as determined by the five studied parameters (p>0.05). The Bland-Altman plot showed an even distribution of the visual analysis method with Lin-Lin , HMM-HR, HMM-CO2, and HMM-RMS. Conclusion The proposed mathematical models were effective in determining the first turn point since they detected the linear pattern change and the deflection point of , HR responses, and sEMG. PMID:24346296

  10. Curved Microneedle Array-Based sEMG Electrode for Robust Long-Term Measurements and High Selectivity

    PubMed Central

    Kim, Minjae; Kim, Taewan; Kim, Dong Sung; Chung, Wan Kyun

    2015-01-01

    Surface electromyography is widely used in many fields to infer human intention. However, conventional electrodes are not appropriate for long-term measurements and are easily influenced by the environment, so the range of applications of sEMG is limited. In this paper, we propose a flexible band-integrated, curved microneedle array electrode for robust long-term measurements, high selectivity, and easy applicability. Signal quality, in terms of long-term usability and sensitivity to perspiration, was investigated. Its motion-discriminating performance was also evaluated. The results show that the proposed electrode is robust to perspiration and can maintain a high-quality measuring ability for over 8 h. The proposed electrode also has high selectivity for motion compared with a commercial wet electrode and dry electrode. PMID:26153773

  11. Toward attenuating the impact of arm positions on electromyography pattern-recognition based motion classification in transradial amputees

    PubMed Central

    2012-01-01

    Background Electromyography (EMG) pattern-recognition based control strategies for multifunctional myoelectric prosthesis systems have been studied commonly in a controlled laboratory setting. Before these myoelectric prosthesis systems are clinically viable, it will be necessary to assess the effect of some disparities between the ideal laboratory setting and practical use on the control performance. One important obstacle is the impact of arm position variation that causes the changes of EMG pattern when performing identical motions in different arm positions. This study aimed to investigate the impacts of arm position variation on EMG pattern-recognition based motion classification in upper-limb amputees and the solutions for reducing these impacts. Methods With five unilateral transradial (TR) amputees, the EMG signals and tri-axial accelerometer mechanomyography (ACC-MMG) signals were simultaneously collected from both amputated and intact arms when performing six classes of arm and hand movements in each of five arm positions that were considered in the study. The effect of the arm position changes was estimated in terms of motion classification error and compared between amputated and intact arms. Then the performance of three proposed methods in attenuating the impact of arm positions was evaluated. Results With EMG signals, the average intra-position and inter-position classification errors across all five arm positions and five subjects were around 7.3% and 29.9% from amputated arms, respectively, about 1.0% and 10% low in comparison with those from intact arms. While ACC-MMG signals could yield a similar intra-position classification error (9.9%) as EMG, they had much higher inter-position classification error with an average value of 81.1% over the arm positions and the subjects. When the EMG data from all five arm positions were involved in the training set, the average classification error reached a value of around 10.8% for amputated arms. Using a

  12. Mapping of spatial and temporal heterogeneity of plantar flexor muscle activity during isometric contraction: correlation of velocity-encoded MRI with EMG

    PubMed Central

    Csapo, Robert; Malis, Vadim; Sinha, Usha

    2015-01-01

    The aim of this study was to assess the correlation between contraction-associated muscle kinematics as measured by velocity-encoded phase-contrast (VE-PC) magnetic resonance imaging (MRI) and activity recorded via electromyography (EMG), and to construct a detailed three-dimensional (3-D) map of the contractile behavior of the triceps surae complex from the MRI data. Ten axial-plane VE-PC MRI slices of the triceps surae and EMG data were acquired during submaximal isometric contractions in 10 subjects. MRI images were analyzed to yield the degree of contraction-associated muscle displacement on a voxel-by-voxel basis and determine the heterogeneity of muscle movement within and between slices. Correlational analyses were performed to determine the agreement between EMG data and displacements. Pearson's coefficients demonstrated good agreement (0.84 < r < 0.88) between EMG data and displacements. Comparison between different slices in the gastrocnemius muscle revealed significant heterogeneity in displacement values both in-plane and along the cranio-caudal axis, with highest values in the mid-muscle regions. By contrast, no significant differences between muscle regions were found in the soleus muscle. Substantial differences among displacements were also observed within slices, with those in static areas being only 17–39% (maximum) of those in the most mobile muscle regions. The good agreement between EMG data and displacements suggests that VE-PC MRI may be used as a noninvasive, high-resolution technique for quantifying and modeling muscle activity over the entire 3-D volume of muscle groups. Application to the triceps surae complex revealed substantial heterogeneity of contraction-associated muscle motion both within slices and between different cranio-caudal positions. PMID:26112239

  13. Electromyography analysis of natural mastication behavior using varying mouthful quantities of two types of gels.

    PubMed

    Kohyama, Kaoru; Gao, Zhihong; Ishihara, Sayaka; Funami, Takahiro; Nishinari, Katsuyoshi

    2016-07-01

    The objectives of this study were to examine the effects of mouthful quantities and mechanical properties of gels on natural mastication behaviors using electromyography (EMG). Two types of hydrocolloid gels (A and K) with similar fracture loads but different moduli and fracture strains were served to eleven normal women in 3-, 6-, 12-, and 24-g masses in a randomized order. EMG activities from both masseter muscles were recorded during natural mastication. Because of the similar fracture loads, the numbers of chews, total muscle activities, and entire oral processing times were similar for similar masses of both gel types. Prior to the first swallow, the more elastic K gel with a higher fracture strain required higher muscle activities than the brittle A gel, which had higher modulus. Majority of subjects had preferred sides of chewing, but all subjects with or without preferred sides used both masseters during the consumption of gels. Similar effects of masses and types of gels were observed in EMG activities of both sides of masseters. Contributions of the dominant side of chewing were diminished with increasing masses of gels, and the mass dependency on ratio of the dominant side was more pronounced with K gel. More repetitions of smaller masses required greater muscle activities and longer periods for the consumption of 24-g gel portions. Reduction in the masses with an increased number of repetitions necessitated slower eating and more mastication to consume the gel portions. These observations suggest that chewing using both sides is more effective and unconsciously reduces mastication times during the consumption of gels. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. The localization of facial motor impairment in sporadic Möbius syndrome.

    PubMed

    Cattaneo, L; Chierici, E; Bianchi, B; Sesenna, E; Pavesi, G

    2006-06-27

    To investigate the neurophysiologic aspects of facial motor control in patients with sporadic Möbius syndrome defined as nonprogressive congenital facial and abducens palsy. The authors assessed 24 patients with sporadic Möbius syndrome by performing a complete clinical examination and neurophysiologic tests including facial nerve conduction studies, needle electromyography examination of facial muscles, and recording of the blink reflex and of the trigeminofacial inhibitory reflex. Two distinct groups of patients were identified according to neurophysiologic testing. The first group was characterized by increased facial distal motor latencies (DMLs) and poor recruitment of small and polyphasic motor unit action potentials (MUAPs). The second group was characterized by normal facial DMLs and neuropathic MUAPs. It is hypothesized that in the first group, the disorder is due to a rhombencephalic maldevelopment with selective sparing of small-size MUs, and in the second group, the disorder is related to an acquired nervous injury during intrauterine life, with subsequent neurogenic remodeling of MUs. The trigeminofacial reflexes showed that in most subjects of both groups, the functional impairment of facial movements was caused by a nuclear or peripheral site of lesion, with little evidence of brainstem interneuronal involvement. Two different neurophysiologically defined phenotypes can be distinguished in sporadic Möbius syndrome, with different pathogenetic implications.

  15. Facial responsiveness of psychopaths to the emotional expressions of others

    PubMed Central

    Mokros, Andreas; Olderbak, Sally; Wilhelm, Oliver

    2018-01-01

    Psychopathic individuals show selfish, manipulative, and antisocial behavior in addition to emotional detachment and reduced empathy. Their empathic deficits are thought to be associated with a reduced responsiveness to emotional stimuli. Immediate facial muscle responses to the emotional expressions of others reflect the expressive part of emotional responsiveness and are positively related to trait empathy. Empirical evidence for reduced facial muscle responses in adult psychopathic individuals to the emotional expressions of others is rare. In the present study, 261 male criminal offenders and non-offenders categorized dynamically presented facial emotion expressions (angry, happy, sad, and neutral) during facial electromyography recording of their corrugator muscle activity. We replicated a measurement model of facial muscle activity, which controls for general facial responsiveness to face stimuli, and modeled three correlated emotion-specific factors (i.e., anger, happiness, and sadness) representing emotion specific activity. In a multi-group confirmatory factor analysis, we compared the means of the anger, happiness, and sadness latent factors between three groups: 1) non-offenders, 2) low, and 3) high psychopathic offenders. There were no significant mean differences between groups. Our results challenge current theories that focus on deficits in emotional responsiveness as leading to the development of psychopathy and encourage further theoretical development on deviant emotional processes in psychopathic individuals. PMID:29324826

  16. Positive fEMG Patterns with Ambiguity in Paintings.

    PubMed

    Jakesch, Martina; Goller, Juergen; Leder, Helmut

    2017-01-01

    Whereas ambiguity in everyday life is often negatively evaluated, it is considered key in art appreciation. In a facial EMG study, we tested whether the positive role of visual ambiguity in paintings is reflected in a continuous affective evaluation on a subtle level. We presented ambiguous (disfluent) and non-ambiguous (fluent) versions of Magritte paintings and found that M. Zygomaticus major activation was higher and M. corrugator supercilii activation was lower for ambiguous than for non-ambiguous versions. Our findings reflect a positive continuous affective evaluation to visual ambiguity in paintings over the 5 s presentation time. We claim that this finding is indirect evidence for the hypothesis that visual stimuli classified as art, evoke a safe state for indulging into experiencing ambiguity, challenging the notion that processing fluency is generally related to positive affect.

  17. Detection of Periodic Leg Movements by Machine Learning Methods Using Polysomnographic Parameters Other Than Leg Electromyography

    PubMed Central

    Umut, İlhan; Çentik, Güven

    2016-01-01

    The number of channels used for polysomnographic recording frequently causes difficulties for patients because of the many cables connected. Also, it increases the risk of having troubles during recording process and increases the storage volume. In this study, it is intended to detect periodic leg movement (PLM) in sleep with the use of the channels except leg electromyography (EMG) by analysing polysomnography (PSG) data with digital signal processing (DSP) and machine learning methods. PSG records of 153 patients of different ages and genders with PLM disorder diagnosis were examined retrospectively. A novel software was developed for the analysis of PSG records. The software utilizes the machine learning algorithms, statistical methods, and DSP methods. In order to classify PLM, popular machine learning methods (multilayer perceptron, K-nearest neighbour, and random forests) and logistic regression were used. Comparison of classified results showed that while K-nearest neighbour classification algorithm had higher average classification rate (91.87%) and lower average classification error value (RMSE = 0.2850), multilayer perceptron algorithm had the lowest average classification rate (83.29%) and the highest average classification error value (RMSE = 0.3705). Results showed that PLM can be classified with high accuracy (91.87%) without leg EMG record being present. PMID:27213008

  18. Detection of Periodic Leg Movements by Machine Learning Methods Using Polysomnographic Parameters Other Than Leg Electromyography.

    PubMed

    Umut, İlhan; Çentik, Güven

    2016-01-01

    The number of channels used for polysomnographic recording frequently causes difficulties for patients because of the many cables connected. Also, it increases the risk of having troubles during recording process and increases the storage volume. In this study, it is intended to detect periodic leg movement (PLM) in sleep with the use of the channels except leg electromyography (EMG) by analysing polysomnography (PSG) data with digital signal processing (DSP) and machine learning methods. PSG records of 153 patients of different ages and genders with PLM disorder diagnosis were examined retrospectively. A novel software was developed for the analysis of PSG records. The software utilizes the machine learning algorithms, statistical methods, and DSP methods. In order to classify PLM, popular machine learning methods (multilayer perceptron, K-nearest neighbour, and random forests) and logistic regression were used. Comparison of classified results showed that while K-nearest neighbour classification algorithm had higher average classification rate (91.87%) and lower average classification error value (RMSE = 0.2850), multilayer perceptron algorithm had the lowest average classification rate (83.29%) and the highest average classification error value (RMSE = 0.3705). Results showed that PLM can be classified with high accuracy (91.87%) without leg EMG record being present.

  19. A quantitative approach to measure women's sexual function using electromyography: a preliminary study of the Kegel exercise.

    PubMed

    Mohktar, Mas Sahidayana; Ibrahim, Fatimah; Mohd Rozi, Nur Farahana; Mohd Yusof, Juhaida; Ahmad, Siti Anom; Su Yen, Khong; Omar, Siti Zawiah

    2013-12-13

    Currently, the reference standard used to clinically assess sexual function among women is a qualitative questionnaire. Hence, a generalised and quantitative measurement tool needs to be available as an alternative. This study investigated whether an electromyography (EMG) measurement technique could be used to help quantify women's sexual function. A preliminary intervention study was conducted on 12 female subjects, who were randomised into a control (n=6) and an intervention (n=6) group. Intervention involved a set regimen of pelvic floor muscle exercises (Kegel) and the control group did not have any treatment. All subjects were asked to answer a validated, self-rated Pelvic Organ Prolapse/Urinary Incontinence Sexual Function Questionnaire (PISQ). EMG measurements of the pelvic floor muscles (PFM) and the abdominal muscles were taken from all women at recruitment and 8 weeks after study commencement. After 8 weeks, most of the subjects in the control group did not display any noted positive difference in either PISQ score (4/6) or in their muscle strength (4/6). However, a noted progressive difference were observed in subjects who were placed in the Kegel group; PISQ score (5/6) and muscles strength (4/6). The noted difference in the Kegel group subjects was that if progress is observed in the sexual function, improvement is also observed in the strength of at least 2 types of muscles (either abdominal or PFM muscles). Thus, EMG measurement is a potential technique to quantify the changes in female sexual function. Further work will be conducted to validate this assumption.

  20. Continuous monitoring of sonomyography, electromyography and torque generated by normal upper arm muscles during isometric contraction: sonomyography assessment for arm muscles.

    PubMed

    Shi, Jun; Zheng, Yong-Ping; Huang, Qing-Hua; Chen, Xin

    2008-03-01

    The aim of this study is to demonstrate the feasibility of using the continuous signals about the thickness and pennation angle changes of muscles detected in real-time from ultrasound images, named as sonomyography (SMG), to characterize muscles under isometric contraction, along with synchronized surface electromyography (EMG) and generated torque signals. The right biceps brachii muscles of seven normal young adult subjects were tested. We observed that exponential functions could well represent the relationships between the normalized EMG root-mean-square (RMS) and the torque, the RMS and the muscle deformation SMG, and the RMS and the pennation angle SMG for the data of the contraction phase, with exponent coefficients of 0.0341 +/- 0.0148 (Mean SD), 0.0619 +/- 0.0273, and 0.0266 +/- 0.0076, respectively. In addition, the preliminary results also demonstrated linear relationships between the normalized torque and the muscle deformation as well as the pennation angle with the ratios of 9 .79 +/- 3.01 and 2.02 +/- 0.53, respectively. The overall mean R2 for the regressions was approximately 0.9 and the overall mean relative root mean square error (RRMSE) smaller than 15%. The potential values of SMG together with EMG to provide a more comprehensive assessment for the muscle functions should be further investigated with more subjects and more muscle groups.

  1. Laryngeal Electromyography Techniques and Clinical Use.

    PubMed

    Kimaid, Paulo Andre Teixeira; Crespo, Agrício Nubiato; Moreira, Ana Lucila; Wolf, Aline Epiphanio; França, Marcondes Cavalcante

    2015-08-01

    Laryngeal electromyography is considered a valuable diagnostic tool for voice disorders. The technique, described almost 70 years ago, evolved 3 decades later, mainly because of the growing interest of laryngologists and speech pathologists. In the authors' opinion, the reduced number of neurophysiologists involved in laryngeal electromyography groups is, at some instance, related to the difficulty to start the learning process and the multidisciplinary approach the field requires. This review highlights the anatomy and physiology needed to perform laryngeal electromyography and its clinical usefulness in the new field known as neurolaryngology.

  2. Comparison between sEMG and force as control interfaces to support planar arm movements in adults with Duchenne: a feasibility study.

    PubMed

    Lobo-Prat, Joan; Nizamis, Kostas; Janssen, Mariska M H P; Keemink, Arvid Q L; Veltink, Peter H; Koopman, Bart F J M; Stienen, Arno H A

    2017-07-12

    Adults with Duchenne muscular dystrophy (DMD) can benefit from devices that actively support their arm function. A critical component of such devices is the control interface as it is responsible for the human-machine interaction. Our previous work indicated that surface electromyography (sEMG) and force-based control with active gravity and joint-stiffness compensation were feasible solutions for the support of elbow movements (one degree of freedom). In this paper, we extend the evaluation of sEMG- and force-based control interfaces to simultaneous and proportional control of planar arm movements (two degrees of freedom). Three men with DMD (18-23 years-old) with different levels of arm function (i.e. Brooke scores of 4, 5 and 6) performed a series of line-tracing tasks over a tabletop surface using an experimental active arm support. The arm movements were controlled using three control methods: sEMG-based control, force-based control with stiffness compensation (FSC), and force-based control with no compensation (FNC). The movement performance was evaluated in terms of percentage of task completion, tracing error, smoothness and speed. For subject S1 (Brooke 4) FNC was the preferred method and performed better than FSC and sEMG. FNC was not usable for subject S2 (Brooke 5) and S3 (Brooke 6). Subject S2 presented significantly lower movement speed with sEMG than with FSC, yet he preferred sEMG since FSC was perceived to be too fatiguing. Subject S3 could not successfully use neither of the two force-based control methods, while with sEMG he could reach almost his entire workspace. Movement performance and subjective preference of the three control methods differed with the level of arm function of the participants. Our results indicate that all three control methods have to be considered in real applications, as they present complementary advantages and disadvantages. The fact that the two weaker subjects (S2 and S3) experienced the force-based control

  3. Deep Learning with Convolutional Neural Networks Applied to Electromyography Data: A Resource for the Classification of Movements for Prosthetic Hands.

    PubMed

    Atzori, Manfredo; Cognolato, Matteo; Müller, Henning

    2016-01-01

    Natural control methods based on surface electromyography (sEMG) and pattern recognition are promising for hand prosthetics. However, the control robustness offered by scientific research is still not sufficient for many real life applications, and commercial prostheses are capable of offering natural control for only a few movements. In recent years deep learning revolutionized several fields of machine learning, including computer vision and speech recognition. Our objective is to test its methods for natural control of robotic hands via sEMG using a large number of intact subjects and amputees. We tested convolutional networks for the classification of an average of 50 hand movements in 67 intact subjects and 11 transradial amputees. The simple architecture of the neural network allowed to make several tests in order to evaluate the effect of pre-processing, layer architecture, data augmentation and optimization. The classification results are compared with a set of classical classification methods applied on the same datasets. The classification accuracy obtained with convolutional neural networks using the proposed architecture is higher than the average results obtained with the classical classification methods, but lower than the results obtained with the best reference methods in our tests. The results show that convolutional neural networks with a very simple architecture can produce accurate results comparable to the average classical classification methods. They show that several factors (including pre-processing, the architecture of the net and the optimization parameters) can be fundamental for the analysis of sEMG data. Larger networks can achieve higher accuracy on computer vision and object recognition tasks. This fact suggests that it may be interesting to evaluate if larger networks can increase sEMG classification accuracy too.

  4. Deep Learning with Convolutional Neural Networks Applied to Electromyography Data: A Resource for the Classification of Movements for Prosthetic Hands

    PubMed Central

    Atzori, Manfredo; Cognolato, Matteo; Müller, Henning

    2016-01-01

    Natural control methods based on surface electromyography (sEMG) and pattern recognition are promising for hand prosthetics. However, the control robustness offered by scientific research is still not sufficient for many real life applications, and commercial prostheses are capable of offering natural control for only a few movements. In recent years deep learning revolutionized several fields of machine learning, including computer vision and speech recognition. Our objective is to test its methods for natural control of robotic hands via sEMG using a large number of intact subjects and amputees. We tested convolutional networks for the classification of an average of 50 hand movements in 67 intact subjects and 11 transradial amputees. The simple architecture of the neural network allowed to make several tests in order to evaluate the effect of pre-processing, layer architecture, data augmentation and optimization. The classification results are compared with a set of classical classification methods applied on the same datasets. The classification accuracy obtained with convolutional neural networks using the proposed architecture is higher than the average results obtained with the classical classification methods, but lower than the results obtained with the best reference methods in our tests. The results show that convolutional neural networks with a very simple architecture can produce accurate results comparable to the average classical classification methods. They show that several factors (including pre-processing, the architecture of the net and the optimization parameters) can be fundamental for the analysis of sEMG data. Larger networks can achieve higher accuracy on computer vision and object recognition tasks. This fact suggests that it may be interesting to evaluate if larger networks can increase sEMG classification accuracy too. PMID:27656140

  5. When should video and EMG be added to urodynamics in children with lower urinary tract dysfunction and is this justified by the evidence? ICI-RS 2014.

    PubMed

    Anding, Ralf; Smith, Phillip; de Jong, Tom; Constantinou, Christos; Cardozo, Linda; Rosier, Peter

    2016-02-01

    An ICI-RS Think Tank in 2014 discussed and evaluated the evidence for adding video and EMG to urodynamics (UDS) in children and also highlighted evidence gaps, with the aim of recommending further clinical and research protocols. A systematic analysis of the relevant literature for both X-ray (video) studies and electromyography, in combination with UDS in children with lower urinary tract dysfunction (LUTD), is summarized in this manuscript. The technical aspects are also critically reviewed. The body of evidence for the addition of X-ray (video) to filling and voiding cystometry and the evidence for the addition of pelvic muscle surface electromyography to urodynamics is scanty and insufficient. Standards are poor and variable so uncontrolled expert opinion dominates practice. The Think Tank has recommended that standardized ALARA ("As Low As Reasonably Achievable") principles should be adopted for video-urodynamics in children. The risk-benefit balance of X-ray exposure needs to be better evaluated and defined. Evaluation of images should be standardized and the association with pressure changes better analyzed and reported. Children's pelvic muscle surface electromyography technique should be standardized, technically improved, and its diagnostic relevance should be better evaluated. © 2016 Wiley Periodicals, Inc.

  6. Olfactory ensheathing glia transplantation combined with LASERPONCTURE in human spinal cord injury: Results measured by electromyography monitoring.

    PubMed

    Bohbot, Albert

    2010-01-01

    Preliminary results were measured by electromyography monitoring (electromyoscan) on three subjects suffering from spinal cord injury and who underwent a double therapy. The aim of this study was to evaluate regained voluntary activity below the injury in subjects who received a double therapy: 1) an olfactory ensheathing glia (OEG) transplantation using procedures developed by Dr. Hongyun Huang at the Xishan Hospital and Rehabilitation Centre, Beijing, China, and 2) LASERPONCTURE developed by Albert Bohbot, Laboratoire de Recherches sur le LASERPONCTURE, La Chapelle Montlinard, France. Materials uses were the LASERPONCTURE device developed by Albert Bohbot; the PROCOMP5 equipment with softwares BIOGRAPH INFINITI 5 and REHAB SUITE; the sensors MYOSCAN-PRO EMG (SA9401M-50) to record muscle activity, and FLEX/PRO-SA9309M to record skin conductance were fixed on the skin. An infrared laser, whose frequencies and power settings cannot be disclosed due to its proprietary nature, was applied after an OEG injection performed according to Dr. Hongyun Huang's procedures. Three cases, two males and one female, were selected for this study. Presentation and comments of the graphs recordings of voluntary muscle activity below the injury are provided. This preliminary study suggests that the double therapy restores some voluntary muscle activity as measured by electromyography monitoring.

  7. Diagnostic yield of electromyography in children with myopathic disorders.

    PubMed

    Ghosh, Partha S; Sorenson, Eric J

    2014-08-01

    Interpretation of pediatric electromyography interpretation in myopathic disorders is technically challenging. We assessed our electromyographic experience with respect to sensitivity and specificity in pediatric myopathy. We did a retrospective chart review of patients ≤18 years between 2009 and 2013. Two hundred twenty-four electromyographic studies were reviewed with the following referral diagnoses: myopathy, muscle weakness, neuromuscular disorders, myositis, myalgia, myoglobinuria, myasthenia, myotonia, cramps, periodic paralysis, hypotonia, and developmental delay. Only children who had an electromyography and muscle biopsy were included for analysis. Patients with neurogenic electromyography and neuromuscular junction disorders were excluded. Myopathic electromyography was defined as short duration, low amplitude, polyphasic motor unit potentials with rapid recruitment. Seventy-two patients were included (age range, 6 months-18 years). The following observations were made: group A: myopathic electromyography or pathognomonic of muscle disease and biopsy or genetically confirmed myopathy (32 cases); group B: myopathic electromyography but biopsy normal or nondiagnostic (12 cases); group C: normal electromyography but biopsy or genetically confirmed myopathy (three cases, all with metabolic myopathy); and group D: electromyography normal and biopsy normal or nondiagnostic (25 cases). The most common diagnoses were congenital myopathy (seven cases), metabolic myopathy (six cases), muscular dystrophy (six cases), genetically confirmed myopathy (five cases), myopathy, undefined (five cases), and inflammatory myopathy (four cases). Pediatric electromyography was 91% sensitive and 67% specific in myopathic disorders. The metabolic myopathies were commonly missed by electromyography. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. Reflex-mediated dynamic neuromuscular stabilization in stroke patients: EMG processing and ultrasound imaging.

    PubMed

    Yoon, Hyun S; You, Joshua Sung H

    2017-07-20

    Postural core instability is associated with poor dynamic balance and a high risk of serious falls. Both neurodevelopmental treatment (NDT) and dynamic neuromuscular stabilization (DNS) core stabilization exercises have been used to improve core stability, but the outcomes of these treatments remain unclear. This study was undertaken to examine the therapeutic effects of NDT and DNS core stabilization exercises on muscular activity, core stability, and core muscle thickness. Ten participants (5 healthy adults; 5 hemiparetic stroke patients) were recruited. Surface electromyography (EMG) was used to determine core muscle activity of the transversus abdominis/internal oblique (TrA/IO), external oblique (EO), and rectus abdominis (RA) muscles. Ultrasound imaging was used to measure transversus abdominals/internal oblique (TrA/IO) thickness, and a pressure biofeedback unit (PBU) was used to measure core stability during the DNS and NDT core exercise conditions. Data are reported as median and range and were compared using nonparametric Mann - Whitney U test and Wilcoxon signed rank test at p< 0.05. Both healthy and hemiparetic stroke groups showed greater median EMG amplitude in the TrA/IO muscles, core stability, and muscle thickness values during the DNS exercise condition than during the NDT core exercise condition, respectively (p< 0.05). However, the relative changes in the EMG amplitude, core stability, and muscle thickness values were greater during the DNS exercise condition than during the NDT core exercise condition in the hemiparetic stroke patient group (p< 0.05). Our novel results provide the first clinical evidence that DNS is more effective than NDT in both healthy and hemiparetic stroke subjects to provide superior deep core muscle activation, core stabilization, and muscle thickness. Moreover, such advantageous therapeutic benefits of the DNS core stabilization exercise over the NDT exercise were more apparent in the hemiparetis stroke patients than

  9. [The effect of EMG level by EMG biofeedback with progressive muscle relaxation training on tension headache].

    PubMed

    Ro, U J; Kim, N C; Kim, H S

    1990-08-01

    The purpose of this study is to assess if EMG biofeedback training with progressive muscle relaxation training is effective in reducing the EMG level in patients with tension headaches. This study which lasted from 23 October to 30 December 1989, was conducted on 10 females who were diagnosed as patients with tension headaches and selected from among volunteers at C. University in Seoul. The process of the study was as follows: First, before the treatment, the baseline was measured for two weeks and the level of EMG was measured five times in five minutes. And then EMG biofeedback training was used for six weeks, 12 sessions in all, and progressive muscle relaxation was done at home by audio tape over eight weeks. Each session was composed of a 5-minute baseline, two 5-minute EMG biofeedback training periods and a 5-minute self-control stage. Each stage was followed by a five minute rest period. So each session took a total of 40 minutes. The EMG level was measured by EMG biofeedback (Autogenic-Cyborg: M 130 EMG module). The results were as follows: 1. The average age of the subjects was 44.1 years and the average history of headache was 10.6 years (range: 6 months-20 years). 2. The level of EMG was lowest between the third and the fourth week of the training except in Cases I and IV. 3. The patients began to show a nonconciliatory attitude at the first session of the fifth week of the training.

  10. Is there any change in pelvic floor electromyography during the first 6 months after radical retropubic prostatectomy?

    PubMed

    Hacad, Claudia R; Glazer, Howard I; Zambon, João Paulo C; Burti, Juliana S; Almeida, Fernando G

    2015-03-01

    The aim of this study is to determine electromyographic pelvic floor muscles activity during the first 6 months post RRP and its relationship to urinary continence. Thirty-eight men (mean age of 63.1 ± 5.7 year) with prostate cancer scheduled for open radical retropubic prostatectomy were evaluated. pelvic radiotherapy, systemic or neurologic diseases, pre-operative International Prostate Symptoms Score (IPSS) >7 and OABq ≥8. Surface electromyography (sEMG) evaluation, IPSS, Urinary Distress Inventory, Incontinence Impact Questionnaire, and Overactive Bladder Questionnaire-short form were applied before and at 1, 3, and 6 months after RRP. Six months after surgery, 18 men (47.4 %) presented urinary leakage. The sEMG evaluations within the first 6 months presented changes in fast contraction amplitude (p = 0.006), rest amplitude after fast contraction (p = 0.04), 10 s sustained contraction mean amplitude (p = 0.024) and final rest amplitude (p = 0.011). We observed that continent and incontinent patients as a group presented electromyographic changes during the first 6 months after radical prostatectomy that could be justified by the denervation/reinnervation of the external urethral sphincter. This finding is consistent with the adaptation of the pelvic floor musculature to the new urethral sphincter condition following surgery.

  11. An EMG-based robot control scheme robust to time-varying EMG signal features.

    PubMed

    Artemiadis, Panagiotis K; Kyriakopoulos, Kostas J

    2010-05-01

    Human-robot control interfaces have received increased attention during the past decades. With the introduction of robots in everyday life, especially in providing services to people with special needs (i.e., elderly, people with impairments, or people with disabilities), there is a strong necessity for simple and natural control interfaces. In this paper, electromyographic (EMG) signals from muscles of the human upper limb are used as the control interface between the user and a robot arm. EMG signals are recorded using surface EMG electrodes placed on the user's skin, making the user's upper limb free of bulky interface sensors or machinery usually found in conventional human-controlled systems. The proposed interface allows the user to control in real time an anthropomorphic robot arm in 3-D space, using upper limb motion estimates based only on EMG recordings. Moreover, the proposed interface is robust to EMG changes with respect to time, mainly caused by muscle fatigue or adjustments of contraction level. The efficiency of the method is assessed through real-time experiments, including random arm motions in the 3-D space with variable hand speed profiles.

  12. Effect of rocuronium on the level and mode of pre-synaptic acetylcholine release by facial and somatic nerves, and changes following facial nerve injury in rabbits.

    PubMed

    Tan, Jinghua; Xu, Jing; Xing, Yian; Chen, Lianhua; Li, Shitong

    2015-01-01

    Muscles innervated by the facial nerve show differential sensitivities to muscle relaxants than muscles innervated by somatic nerves. The evoked electromyography (EEMG) response is also proportionally reduced after facial nerve injury. This forms the theoretical basis for proper utilization of muscle relaxants to balance EEMG monitoring and immobility under general anesthesia. (1) To observe the relationships between the level and mode of acetylcholine (ACh) release and the duration of facial nerve injury, and the influence of rocuronium in an in vitro rabbit model. (2) To explore the pre-synaptic mechanisms of discrepant responses to a muscle relaxant. Quantal and non-quantal ACh release were measured by using intracellular microelectrode recording in the orbicularis oris 1 to 42 days after graded facial nerve injury and in the gastrocnemius with/without rocuronium. Quantal ACh release was significantly decreased by rocuronium in the orbicularis oris and gastrocnemius, but significantly more so in gastrocnemius. Quantal release was reduced after facial nerve injury, which was significantly correlated with the severity of nerve injury in the absence but not in the presence of rocuronium. Non-quantal ACh release was reduced after facial nerve injury, with many relationships observed depending on the extent of the injury. The extent of inhibition of non-quantal release by rocuronium correlated with the grade of facial nerve injury. These findings may explain why EEMG amplitude might be diminished after acute facial nerve injury but relatively preserved after chronic injury and differential responses in sensitivity to rocuronium.

  13. Effect of rocuronium on the level and mode of pre-synaptic acetylcholine release by facial and somatic nerves, and changes following facial nerve injury in rabbits

    PubMed Central

    Tan, Jinghua; Xu, Jing; Xing, Yian; Chen, Lianhua; Li, Shitong

    2015-01-01

    Muscles innervated by the facial nerve show differential sensitivities to muscle relaxants than muscles innervated by somatic nerves. The evoked electromyography (EEMG) response is also proportionally reduced after facial nerve injury. This forms the theoretical basis for proper utilization of muscle relaxants to balance EEMG monitoring and immobility under general anesthesia. (1) To observe the relationships between the level and mode of acetylcholine (ACh) release and the duration of facial nerve injury, and the influence of rocuronium in an in vitro rabbit model. (2) To explore the pre-synaptic mechanisms of discrepant responses to a muscle relaxant. Quantal and non-quantal ACh release were measured by using intracellular microelectrode recording in the orbicularis oris 1 to 42 days after graded facial nerve injury and in the gastrocnemius with/without rocuronium. Quantal ACh release was significantly decreased by rocuronium in the orbicularis oris and gastrocnemius, but significantly more so in gastrocnemius. Quantal release was reduced after facial nerve injury, which was significantly correlated with the severity of nerve injury in the absence but not in the presence of rocuronium. Non-quantal ACh release was reduced after facial nerve injury, with many relationships observed depending on the extent of the injury. The extent of inhibition of non-quantal release by rocuronium correlated with the grade of facial nerve injury. These findings may explain why EEMG amplitude might be diminished after acute facial nerve injury but relatively preserved after chronic injury and differential responses in sensitivity to rocuronium. PMID:25973033

  14. Occlusal splint versus modified nociceptive trigeminal inhibition splint in bruxism therapy: a randomized, controlled trial using surface electromyography.

    PubMed

    Dalewski, B; Chruściel-Nogalska, M; Frączak, B

    2015-12-01

    An occlusal splint and a modified nociceptive trigeminal inhibition splint (AMPS, anterior deprogrammer, Kois deprogrammer, Lucia jig, etc.) are commonly and quite frequently used in the treatment of masticatory muscle disorders, although their sustainable and long-lasting effect on these muscles' function is still not very well known. Results of scant surface electromyography studies in patients with temporomandibular disorders have been contradictory. The aim of this study was to evaluate both devices in bruxism therapy; EMG activity levels during postural activity and maximum voluntary contraction of the superficial temporal and masseter muscles were compared before and after 30 days of treatment. Surface electromyography of the examined muscles was performed in two groups of bruxers (15 patients each). Patients in the first group used occlusal splints, while those in the second used modified nociceptive trigeminal inhibition splints. The trial was randomized, controlled and semi-blind. Neither device affected the asymmetry index or postural activity/maximum voluntary contraction ratio after 1 month of treatment. Neither the occlusal nor the nociceptive trigeminal inhibition splint showed any significant influence on the examined muscles. Different scientific methods should be considered in clinical applications that require either direct influence on the muscles' bioelectrical activity or a quantitative measurement of the treatment quality. © 2015 Australian Dental Association.

  15. Motor unit size estimation: confrontation of surface EMG with macro EMG.

    PubMed

    Roeleveld, K; Stegeman, D F; Falck, B; Stålberg, E V

    1997-06-01

    Surface EMG (SEMG) is little used for diagnostic purposes in clinical neurophysiology, mainly because it provides little direct information on individual motor units (MUs). One of the techniques to estimate the MU size is intra-muscular Macro EMG. The present study compares SEMG with Macro EMG. Fifty-eight channel SEMG was recorded simultaneously with Macro EMG. Individual MUPs were obtained by single fiber triggered averaging. All recordings were made from the biceps brachii of healthy subjects during voluntary contraction at low force. High positive correlations were found between all Macro and Surface motor unit potential (MUP) parameters: area, peak-to-peak amplitude, negative peak amplitude and positive peak amplitude. The MUPs recorded with SEMG were dependent on the distance between the MU and the skin surface. Normalizing the SEMG parameters for MU location did not improve the correlation coefficient between the parameters of both techniques. The two measurement techniques had almost the same relative range in MUP parameters in any individual subject compared to the others, especially after normalizing the surface MUP parameters for MU location. MUPs recorded with this type of SEMG provide useful information about the MU size.

  16. Laryngeal electromyography as a diagnostic tool for Parkinson's disease.

    PubMed

    Zarzur, Ana P; Duprat, André de Campos; Cataldo, Berenice O; Ciampi, Daniel; Fonoff, Erich

    2014-03-01

    To study the laryngeal electromyography pattern in patients with Parkinson's disease (PD) and vocal complaints at different stages of the disease. Cross-sectional cohort study. Ninety-four adults with PD and vocal complaints at different stages of the disease (according to the Hoehn and Yahr scale) underwent laryngeal electromyography. Tremors were not detected on laryngeal electromyography of the cricothyroid and thyroarytenoid muscles even in patients with clinical tremor. Laryngeal electromyography hypercontractility during voice rest was the typical result observed in 91.5% of patients regardless of disease severity. Gender and age of subjects did not correlate with laryngeal electromyography results. Patients with PD presented spontaneous intrinsic laryngeal muscle activity during voice rest, regardless of disease severity. This study was significant because it reported on the use of laryngeal electromyography in a large number of patients with PD and vocal complaints grouped according to PD severity. The patterns observed suggest that laryngeal electromyography is a valuable diagnostic tool for PD even at early phases of the disease. © 2013 The American Laryngological, Rhinological and Otological Society, Inc.

  17. [Laryngeal electromyography in diagnosis and treatment of voice disorders].

    PubMed

    García-López, Isabel; Santiago-Pérez, Susana; Peñarrocha-Teres, Julio; del Palacio, Antonio J; Gavilan, Javier

    2012-01-01

    Laryngeal electromyography, together with clinical evaluation, is a valuable tool in voice disorder management. It assesses the integrity of laryngeal nerves and muscles, contributing to the diagnosis of many diseases, especially laryngeal movement disorders. Our purpose was to describe the experience of the first Spanish series with laryngeal electromyography in evaluating voice disorders. A prospective study was designed to evaluate laryngeal movement disorders with laryngeal electromyography. Both the cricothyroid and thyroarytenoid muscles were tested routinely and, in some cases, the posterior cricoarytenoid muscle. The laryngeal electromyography technique and result interpretation were performed by a laryngologist and a neurophysiologist. We included 110 patients, with the most common symptom being dysphonia. Laryngeal electromyography was performed in 85% of cases. Primary diagnosis before electromyography was laryngeal immobility. Positive predictive value for diagnosis in cases of paralysis was 88%. Laryngeal electromyography is a useful adjunct, together with clinical evaluation, for diagnosis and management of motion abnormalities in the larynx in patients who present with dysphonia. Copyright © 2012 Elsevier España, S.L. All rights reserved.

  18. Wideband EMG telemetry system

    NASA Technical Reports Server (NTRS)

    Rosatino, S. A.; Westbrook, R. M.

    1979-01-01

    Miniature, individual crystal-controlled RF transmitters located in EMG pressure sensors simplifies multichannel EMG telemetry for electronic gait monitoring. Transmitters which are assigned operating frequencies within 174 - 216 MHz band have linear frequency response from 20 - 2000 Hz and operate over range of 15 m.

  19. Processing emotions: Effects of menstrual cycle phase and premenstrual symptoms on the startle reflex, facial EMG and heart rate.

    PubMed

    Armbruster, Diana; Grage, Tobias; Kirschbaum, Clemens; Strobel, Alexander

    2018-10-01

    Emotional reactivity varies across the menstrual cycle although physiological findings are not entirely consistent. We assessed facial EMG and heart rate (HR) changes in healthy free cycling women (N = 45) with an emotional startle paradigm both during the early follicular and the late luteal phase, verified by repeated salivary 17β-estradiol, progesterone and testosterone assessments. Cycle phase impacted startle responses with larger magnitudes during the luteal phase. Notably, this effect was only present when premenstrual symptoms and sequence of lab sessions were included as co-variates. At rest, participants showed a tendency towards higher HR and reduced high frequency (HF) power during the luteal phase indicating reduced parasympathetic tone. HF power was also negatively associated with startle magnitudes. HR changes in response to emotional images differed between the two cycle phases. Initial HR deceleration was more marked during the follicular phase particularly when viewing negative pictures. However, cycle phase did not significantly impact corrugator and zygomaticus activity in response to emotional pictures. Among the three gonadal steroids, correlation patterns were most consistent for testosterone. During the follicular phase, testosterone was associated with zygomaticus activity while viewing neutral or positive pictures and with less pronounced HR deceleration in response to negative images. During the luteal phase, testosterone was negatively associated with fear potentiated startle. The findings underscore the importance of considering menstrual cycle phase when investigating physiological indicators of emotion. However, the modulating effect of premenstrual symptoms also emphasizes potential inter-individual differences. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. Fatigue effects upon sticking region and electromyography in a six-repetition maximum bench press.

    PubMed

    van den Tillaar, Roland; Saeterbakken, Atle Hole

    2013-01-01

    The aim of the study was to examine the sticking region and concomitant neuromuscular activation of the prime movers during six-repetition maximum (RM) bench pressing. We hypothesised that both peak velocities would decrease and that the electromyography (EMG) of the prime movers (deltoid, major pectoralis and triceps) would increase during the pre-sticking and sticking region during the six repetitions due to fatigue. Thirteen resistance-trained males (age 22.8 ± 2.2 years, stature 1.82 ± 0.06 m, body mass 83.4 ± 7.6 kg) performed 6-RM bench presses. Barbell kinematics and EMG activity of pectoralis major, deltoid anterior, and triceps brachii during the pre-, sticking and post-sticking region of each repetition in a 6-RM bench press were analysed. For both the sticking as the post-sticking region, the time increased significantly from the first to the sixth repetition. Vertical barbell height at the start of sticking region was lower, while the height at the end of the sticking region and post-sticking region did not change during the six repetitions. It was concluded that in 6-RM bench pressing performance, the sticking region is a poor mechanical force region due to the unchanged barbell height at the end of the sticking region. Furthermore, when fatigue occurs, the pectoralis and the deltoid muscles are responsible for surpassing the sticking region as indicated by their increased activity during the pre- and sticking region during the six-repetitions bench press.

  1. A Novel Feature Optimization for Wearable Human-Computer Interfaces Using Surface Electromyography Sensors

    PubMed Central

    Zhang, Xiong; Zhao, Yacong; Zhang, Yu; Zhong, Xuefei; Fan, Zhaowen

    2018-01-01

    The novel human-computer interface (HCI) using bioelectrical signals as input is a valuable tool to improve the lives of people with disabilities. In this paper, surface electromyography (sEMG) signals induced by four classes of wrist movements were acquired from four sites on the lower arm with our designed system. Forty-two features were extracted from the time, frequency and time-frequency domains. Optimal channels were determined from single-channel classification performance rank. The optimal-feature selection was according to a modified entropy criteria (EC) and Fisher discrimination (FD) criteria. The feature selection results were evaluated by four different classifiers, and compared with other conventional feature subsets. In online tests, the wearable system acquired real-time sEMG signals. The selected features and trained classifier model were used to control a telecar through four different paradigms in a designed environment with simple obstacles. Performance was evaluated based on travel time (TT) and recognition rate (RR). The results of hardware evaluation verified the feasibility of our acquisition systems, and ensured signal quality. Single-channel analysis results indicated that the channel located on the extensor carpi ulnaris (ECU) performed best with mean classification accuracy of 97.45% for all movement’s pairs. Channels placed on ECU and the extensor carpi radialis (ECR) were selected according to the accuracy rank. Experimental results showed that the proposed FD method was better than other feature selection methods and single-type features. The combination of FD and random forest (RF) performed best in offline analysis, with 96.77% multi-class RR. Online results illustrated that the state-machine paradigm with a 125 ms window had the highest maneuverability and was closest to real-life control. Subjects could accomplish online sessions by three sEMG-based paradigms, with average times of 46.02, 49.06 and 48.08 s, respectively. These

  2. A Novel Phonology- and Radical-Coded Chinese Sign Language Recognition Framework Using Accelerometer and Surface Electromyography Sensors

    PubMed Central

    Cheng, Juan; Chen, Xun; Liu, Aiping; Peng, Hu

    2015-01-01

    Sign language recognition (SLR) is an important communication tool between the deaf and the external world. It is highly necessary to develop a worldwide continuous and large-vocabulary-scale SLR system for practical usage. In this paper, we propose a novel phonology- and radical-coded Chinese SLR framework to demonstrate the feasibility of continuous SLR using accelerometer (ACC) and surface electromyography (sEMG) sensors. The continuous Chinese characters, consisting of coded sign gestures, are first segmented into active segments using EMG signals by means of moving average algorithm. Then, features of each component are extracted from both ACC and sEMG signals of active segments (i.e., palm orientation represented by the mean and variance of ACC signals, hand movement represented by the fixed-point ACC sequence, and hand shape represented by both the mean absolute value (MAV) and autoregressive model coefficients (ARs)). Afterwards, palm orientation is first classified, distinguishing “Palm Downward” sign gestures from “Palm Inward” ones. Only the “Palm Inward” gestures are sent for further hand movement and hand shape recognition by dynamic time warping (DTW) algorithm and hidden Markov models (HMM) respectively. Finally, component recognition results are integrated to identify one certain coded gesture. Experimental results demonstrate that the proposed SLR framework with a vocabulary scale of 223 characters can achieve an averaged recognition accuracy of 96.01% ± 0.83% for coded gesture recognition tasks and 92.73% ± 1.47% for character recognition tasks. Besides, it demonstrats that sEMG signals are rather consistent for a given hand shape independent of hand movements. Hence, the number of training samples will not be significantly increased when the vocabulary scale increases, since not only the number of the completely new proposed coded gestures is constant and limited, but also the transition movement which connects successive signs

  3. A Novel Phonology- and Radical-Coded Chinese Sign Language Recognition Framework Using Accelerometer and Surface Electromyography Sensors.

    PubMed

    Cheng, Juan; Chen, Xun; Liu, Aiping; Peng, Hu

    2015-09-15

    Sign language recognition (SLR) is an important communication tool between the deaf and the external world. It is highly necessary to develop a worldwide continuous and large-vocabulary-scale SLR system for practical usage. In this paper, we propose a novel phonology- and radical-coded Chinese SLR framework to demonstrate the feasibility of continuous SLR using accelerometer (ACC) and surface electromyography (sEMG) sensors. The continuous Chinese characters, consisting of coded sign gestures, are first segmented into active segments using EMG signals by means of moving average algorithm. Then, features of each component are extracted from both ACC and sEMG signals of active segments (i.e., palm orientation represented by the mean and variance of ACC signals, hand movement represented by the fixed-point ACC sequence, and hand shape represented by both the mean absolute value (MAV) and autoregressive model coefficients (ARs)). Afterwards, palm orientation is first classified, distinguishing "Palm Downward" sign gestures from "Palm Inward" ones. Only the "Palm Inward" gestures are sent for further hand movement and hand shape recognition by dynamic time warping (DTW) algorithm and hidden Markov models (HMM) respectively. Finally, component recognition results are integrated to identify one certain coded gesture. Experimental results demonstrate that the proposed SLR framework with a vocabulary scale of 223 characters can achieve an averaged recognition accuracy of 96.01% ± 0.83% for coded gesture recognition tasks and 92.73% ± 1.47% for character recognition tasks. Besides, it demonstrats that sEMG signals are rather consistent for a given hand shape independent of hand movements. Hence, the number of training samples will not be significantly increased when the vocabulary scale increases, since not only the number of the completely new proposed coded gestures is constant and limited, but also the transition movement which connects successive signs needs no

  4. Behind the Robot’s Smiles and Frowns: In Social Context, People Do Not Mirror Android’s Expressions But React to Their Informational Value

    PubMed Central

    Hofree, Galit; Ruvolo, Paul; Reinert, Audrey; Bartlett, Marian S.; Winkielman, Piotr

    2018-01-01

    Facial actions are key elements of non-verbal behavior. Perceivers’ reactions to others’ facial expressions often represent a match or mirroring (e.g., they smile to a smile). However, the information conveyed by an expression depends on context. Thus, when shown by an opponent, a smile conveys bad news and evokes frowning. The availability of anthropomorphic agents capable of facial actions raises the question of how people respond to such agents in social context. We explored this issue in a study where participants played a strategic game with or against a facially expressive android. Electromyography (EMG) recorded participants’ reactions over zygomaticus muscle (smiling) and corrugator muscle (frowning). We found that participants’ facial responses to android’s expressions reflect their informational value, rather than a direct match. Overall, participants smiled more, and frowned less, when winning than losing. Critically, participants’ responses to the game outcome were similar regardless of whether it was conveyed via the android’s smile or frown. Furthermore, the outcome had greater impact on people’s facial reactions when it was conveyed through android’s face than a computer screen. These findings demonstrate that facial actions of artificial agents impact human facial responding. They also suggest a sophistication in human-robot communication that highlights the signaling value of facial expressions. PMID:29740307

  5. Behind the Robot's Smiles and Frowns: In Social Context, People Do Not Mirror Android's Expressions But React to Their Informational Value.

    PubMed

    Hofree, Galit; Ruvolo, Paul; Reinert, Audrey; Bartlett, Marian S; Winkielman, Piotr

    2018-01-01

    Facial actions are key elements of non-verbal behavior. Perceivers' reactions to others' facial expressions often represent a match or mirroring (e.g., they smile to a smile). However, the information conveyed by an expression depends on context. Thus, when shown by an opponent, a smile conveys bad news and evokes frowning. The availability of anthropomorphic agents capable of facial actions raises the question of how people respond to such agents in social context. We explored this issue in a study where participants played a strategic game with or against a facially expressive android. Electromyography (EMG) recorded participants' reactions over zygomaticus muscle (smiling) and corrugator muscle (frowning). We found that participants' facial responses to android's expressions reflect their informational value, rather than a direct match. Overall, participants smiled more, and frowned less, when winning than losing. Critically, participants' responses to the game outcome were similar regardless of whether it was conveyed via the android's smile or frown. Furthermore, the outcome had greater impact on people's facial reactions when it was conveyed through android's face than a computer screen. These findings demonstrate that facial actions of artificial agents impact human facial responding. They also suggest a sophistication in human-robot communication that highlights the signaling value of facial expressions.

  6. Simultaneous Recording and Analysis of Uterine and Abdominal Muscle Electromyographic Activity in Nulliparous Women During Labor.

    PubMed

    Qian, Xueya; Li, Pin; Shi, Shao-Qing; Garfield, Robert E; Liu, Huishu

    2017-03-01

    To record and characterize electromyography (EMG) from the uterus and abdominal muscles during the nonlabor to first and second stages of labor and to define relationships to contractions. Nulliparous patients without any treatments were used (n = 12 nonlabor stage, 48 during first stage and 33 during second stage). Electromyography of both uterine and abdominal muscles was simultaneously recorded from electrodes placed on patients' abdominal surface using filters to separate uterine and abdominal EMG. Contractions of muscles were also recorded using tocodynamometry. Electromyography was characterized by analysis of various parameters. During the first stage of labor, when abdominal EMG is absent, uterine EMG bursts temporally correspond to contractions. In the second stage, uterine EMG bursts usually occur at same frequency as groups of abdominal bursts and precede abdominal bursts, whereas abdominal EMG bursts correspond to contractions and are accompanied by feelings of "urge to push." Uterine EMG increases progressively from nonlabor to second stage of labor. (1) Uterine EMG activity can be separated from abdominal EMG events by filtering. (2) Uterine EMG gradually evolves from the antepartum stage to the first and second stages of labor. (3) Uterine and abdominal EMG reflect electrical activity of the muscles during labor and are valuable to assess uterine and abdominal muscle events that control labor. (4) During the first stage of labor uterine, EMG is responsible for contractions, and during the second stage, both uterine and abdominal muscle participate in labor.

  7. An Overview of Laryngeal Muscle Single Fiber Electromyography.

    PubMed

    Bertorini, Tulio E; Sharaf, Aboubakar G

    2015-08-01

    Needle electromyography is an important tool in the diagnosis of neuromuscular diseases and has also been applied successfully in the evaluation of the vocal cord paralysis. Laryngeal electromyography, initially described by Weddell, is used to determine the cause of vocal cord paralysis and to differentiate organic from nonorganic causes of speech disorders. This test allows the diagnosis of lower motor neuron and nerve paralysis as well as myopathies. Laryngeal electromyography also helps to determine the prognosis of paralysis caused by traumatic injury of the laryngeal nerves and is used for guidance during botulinum toxin injection in spasmodic dysphonias. Single fiber electromyography is used to diagnose abnormalities of neuromuscular transmission and is applied in the study the architecture of the motor unit in muscles. This article reviews the techniques of laryngeal muscles single fiber electromyography, provides limited informative data, and discusses its potential value in the evaluation of patients with dysphonia.

  8. Leg surface electromyography patterns in children with neuro-orthopedic disorders walking on a treadmill unassisted and assisted by a robot with and without encouragement

    PubMed Central

    2013-01-01

    Background Robot-assisted gait training and treadmill training can complement conventional physical therapy in children with neuro-orthopedic movement disorders. The aim of this study was to investigate surface electromyography (sEMG) activity patterns during robot-assisted gait training (with and without motivating instructions from a therapist) and unassisted treadmill walking and to compare these with physiological sEMG patterns. Methods Nine children with motor impairments and eight healthy children walked in various conditions: (a) on a treadmill in the driven gait orthosis Lokomat®, (b) same condition, with additional motivational instructions from a therapist, and (c) on the treadmill without assistance. sEMG recordings were made of the tibialis anterior, gastrocnemius lateralis, vastus medialis, and biceps femoris muscles. Differences in sEMG amplitudes between the three conditions were analyzed for the duration of stance and swing phase (for each group and muscle separately) using non-parametric tests. Spearman’s correlation coefficients illustrated similarity of muscle activation patterns between conditions, between groups, and with published reference trajectories. Results The relative duration of stance and swing phase differed between patients and controls, and between driven gait orthosis conditions and treadmill walking. While sEMG amplitudes were higher when being encouraged by a therapist compared to robot-assisted gait training without instructions (0.008 ≤ p-value ≤ 0.015), muscle activation patterns were highly comparable (0.648 ≤ Spearman correlation coefficients ≤ 0.969). In general, comparisons of the sEMG patterns with published reference data of over-ground walking revealed that walking in the driven gait orthosis could induce more physiological muscle activation patterns compared to unsupported treadmill walking. Conclusions Our results suggest that robotic-assisted gait training with therapeutic encouragement

  9. History of electromyography and nerve conduction studies: A tribute to the founding fathers.

    PubMed

    Kazamel, Mohamed; Warren, Paula Province

    2017-09-01

    The early development of nerve conduction studies (NCS) and electromyography (EMG) was linked to the discovery of electricity. This relationship had been concluded by observing the effect of applying electricity to the body of an animal and discovering that nerves and muscles themselves could produce electricity. We attempt to review the historical evolution of NCS and EMG over the last three centuries by reviewing the landmark publications of Galvani, Adrian, Denny-Brown, Larrabee, and Lambert. In 1771, Galvani showed that electrical stimulation of animal muscle tissue produced contraction and, thereby, the concept of animal electricity was born. In 1929, Adrian devised a method to record a single motor unit potential by connecting concentric needle electrodes to an amplifier and a loud speaker. In 1938, Denny-Brown described the fasciculation potentials and separated them from fibrillations. Toward the end of World War II, Larrabee began measuring the compound muscle action potential in healthy and injured nerves of war victims. In 1957, Lambert and Eaton described the electrophysiologic features of a new myasthenic syndrome associated with lung carcinoma. Overall, research on this topic was previously undertaken by neurophysiologists and then later by neurologists, with Adrian most likely being the first neurologist to be involved. The field greatly benefited from the invention of equipment that was capable of amplifying small bioelectrical currents by the beginning of the 20th century. Significant scientific and technical advances were later made during and after World War II which provided a large patient population with nerve injuries to study. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. A stretchable electrode array for non-invasive, skin-mounted measurement of electrocardiography (ECG), electromyography (EMG) and electroencephalography (EEG).

    PubMed

    Ma, Rui; Kim, Dae-Hyeong; McCormick, Martin; Coleman, Todd; Rogers, John

    2010-01-01

    This paper reports a class of stretchable electrode array capable of intimate, conformal integration onto the curvilinear surfaces of skin on the human body. The designs employ conventional metallic conductors but in optimized mechanical layouts, on soft, thin elastomeric substrates. These devices exhibit an ability to record spontaneous EEG activity even without conductive electrolyte gels, with recorded alpha rhythm responses that are 40% stronger than those collected using conventional tin electrodes and gels under otherwise similar conditions. The same type of device can also measure high quality ECG and EMG signals. The results suggest broad utility for skin-mounted measurements of electrical activity in the body, with advantages in signal levels, wearability and modes of integration compared to alternatives.

  11. Surface electromyographic mapping of the orbicularis oculi muscle for real-time blink detection.

    PubMed

    Frigerio, Alice; Cavallari, Paolo; Frigeni, Marta; Pedrocchi, Alessandra; Sarasola, Andrea; Ferrante, Simona

    2014-01-01

    Facial paralysis is a life-altering condition that significantly impairs function, appearance, and communication. Facial rehabilitation via closed-loop pacing represents a potential but as yet theoretical approach to reanimation. A first critical step toward closed-loop facial pacing in cases of unilateral paralysis is the detection of healthy movements to use as a trigger to prosthetically elicit automatic artificial movements on the contralateral side of the face. To test and to maximize the performance of an electromyography (EMG)-based blink detection system for applications in closed-loop facial pacing. Blinking was detected across the periocular region by means of multichannel surface EMG at an academic neuroengineering and medical robotics laboratory among 15 healthy volunteers. Real-time blink detection was accomplished by mapping the surface of the orbicularis oculi muscle on one side of the face with a multichannel surface EMG. The biosignal from each channel was independently processed; custom software registered a blink when an amplitude-based or slope-based suprathreshold activity was detected. The experiments were performed when participants were relaxed and during the production of particular orofacial movements. An F1 score metric was used to analyze software performance in detecting blinks. The maximal software performance was achieved when a blink was recorded from the superomedial orbit quadrant. At this recording location, the median F1 scores were 0.89 during spontaneous blinking, 0.82 when chewing gum, 0.80 when raising the eyebrows, and 0.70 when smiling. The overall performance of blink detection was significantly better at the superomedial quadrant (F1 score, 0.75) than at the traditionally used inferolateral quadrant (F1 score, 0.40) (P < .05). Electromyographic recording represents an accurate tool to detect spontaneous blinks as part of closed-loop facial pacing systems. The early detection of blink activity may allow real

  12. Reliability of surface electromyography activity of gluteal and hamstring muscles during sub-maximal and maximal voluntary isometric contractions.

    PubMed

    Bussey, Melanie D; Aldabe, Daniela; Adhia, Divya; Mani, Ramakrishnan

    2018-04-01

    Normalizing to a reference signal is essential when analysing and comparing electromyography signals across or within individuals. However, studies have shown that MVC testing may not be as reliable in persons with acute and chronic pain. The purpose of this study was to compare the test-retest reliability of the muscle activity in the biceps femoris and gluteus maximus between a novel sub-MVC and standard MVC protocols. This study utilized a single individual repeated measures design with 12 participants performing multiple trials of both the sub-MVC and MVC tasks on two separate days. The participant position in the prone leg raise task was standardised with an ultrasonic sensor to improve task precession between trials/days. Day-to-day and trial-to-trial reliability of the maximal muscle activity was examined using ICC and SEM. Day-to-day and trial-to-trial reliability of the EMG activity in the BF and GM were high (0.70-0.89) to very high (≥0.90) for both test procedures. %SEM was <5-10% for both tests on a given day but higher in the day-to-day comparisons. The lower amplitude of the sub-MVC is a likely contributor to increased %SEM (8-13%) in the day-to-day comparison. The findings show that the sub-MVC modified prone double leg raise results in GM and BF EMG measures similar in reliability and precision to the standard MVC tasks. Therefore, the modified prone double leg raise may be a useful substitute for traditional MVC testing for normalizing EMG signals of the BF and GM. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Effects of electromyography-driven robot-aided hand training with neuromuscular electrical stimulation on hand control performance after chronic stroke.

    PubMed

    Rong, Wei; Tong, Kai Yu; Hu, Xiao Ling; Ho, Sze Kit

    2015-03-01

    An electromyography-driven robot system integrated with neuromuscular electrical stimulation (NMES) was developed to investigate its effectiveness on post-stroke rehabilitation. The performance of this system in assisting finger flexion/extension with different assistance combinations was evaluated in five stroke subjects. Then, a pilot study with 20-sessions training was conducted to evaluate the training's effectiveness. The results showed that combined assistance from the NMES-robot could improve finger movement accuracy, encourage muscle activation of the finger muscles and suppress excessive muscular activities in the elbow joint. When assistances from both NMES and the robot were 50% of their maximum assistances, finger-tracking performance had the best results, with the lowest root mean square error, greater range of motion, higher voluntary muscle activations of the finger joints and lower muscle co-contraction in the finger and elbow joints. Upper limb function improved after the 20-session training, indicated by the increased clinical scores of Fugl-Meyer Assessment, Action Research Arm Test and Wolf Motor Function Test. Muscle co-contraction was reduced in the finger and elbow joints reflected by the Modified Ashworth Scale. The findings demonstrated that an electromyography-driven NMES-robot used for chronic stroke improved hand function and tracking performance. Further research is warranted to validate the method on a larger scale. Implications for Rehabilitation The hand robotics and neuromuscular electrical stimulation (NMES) techniques are still separate systems in current post-stroke hand rehabilitation. This is the first study to investigate the combined effects of the NMES and robot on hand rehabilitation. The finger tracking performance was improved with the combined assistance from the EMG-driven NMES-robot hand system. The assistance from the robot could improve the finger movement accuracy and the assistance from the NMES could reduce the

  14. Gesture Based Control and EMG Decomposition

    NASA Technical Reports Server (NTRS)

    Wheeler, Kevin R.; Chang, Mindy H.; Knuth, Kevin H.

    2005-01-01

    This paper presents two probabilistic developments for use with Electromyograms (EMG). First described is a new-electric interface for virtual device control based on gesture recognition. The second development is a Bayesian method for decomposing EMG into individual motor unit action potentials. This more complex technique will then allow for higher resolution in separating muscle groups for gesture recognition. All examples presented rely upon sampling EMG data from a subject's forearm. The gesture based recognition uses pattern recognition software that has been trained to identify gestures from among a given set of gestures. The pattern recognition software consists of hidden Markov models which are used to recognize the gestures as they are being performed in real-time from moving averages of EMG. Two experiments were conducted to examine the feasibility of this interface technology. The first replicated a virtual joystick interface, and the second replicated a keyboard. Moving averages of EMG do not provide easy distinction between fine muscle groups. To better distinguish between different fine motor skill muscle groups we present a Bayesian algorithm to separate surface EMG into representative motor unit action potentials. The algorithm is based upon differential Variable Component Analysis (dVCA) [l], [2] which was originally developed for Electroencephalograms. The algorithm uses a simple forward model representing a mixture of motor unit action potentials as seen across multiple channels. The parameters of this model are iteratively optimized for each component. Results are presented on both synthetic and experimental EMG data. The synthetic case has additive white noise and is compared with known components. The experimental EMG data was obtained using a custom linear electrode array designed for this study.

  15. Perceptual integration of kinematic components in the recognition of emotional facial expressions.

    PubMed

    Chiovetto, Enrico; Curio, Cristóbal; Endres, Dominik; Giese, Martin

    2018-04-01

    According to a long-standing hypothesis in motor control, complex body motion is organized in terms of movement primitives, reducing massively the dimensionality of the underlying control problems. For body movements, this low-dimensional organization has been convincingly demonstrated by the learning of low-dimensional representations from kinematic and EMG data. In contrast, the effective dimensionality of dynamic facial expressions is unknown, and dominant analysis approaches have been based on heuristically defined facial "action units," which reflect contributions of individual face muscles. We determined the effective dimensionality of dynamic facial expressions by learning of a low-dimensional model from 11 facial expressions. We found an amazingly low dimensionality with only two movement primitives being sufficient to simulate these dynamic expressions with high accuracy. This low dimensionality is confirmed statistically, by Bayesian model comparison of models with different numbers of primitives, and by a psychophysical experiment that demonstrates that expressions, simulated with only two primitives, are indistinguishable from natural ones. In addition, we find statistically optimal integration of the emotion information specified by these primitives in visual perception. Taken together, our results indicate that facial expressions might be controlled by a very small number of independent control units, permitting very low-dimensional parametrization of the associated facial expression.

  16. Region-dependent hamstrings activity in Nordic hamstring exercise and stiff-leg deadlift defined with high-density electromyography.

    PubMed

    Hegyi, A; Péter, A; Finni, T; Cronin, N J

    2018-03-01

    Recent studies suggest region-specific metabolic activity in hamstring muscles during injury prevention exercises, but the neural representation of this phenomenon is unknown. The aim of this study was to examine whether regional differences are evident in the activity of biceps femoris long head (BFlh) and semitendinosus (ST) muscles during two common injury prevention exercises. Twelve male participants without a history of hamstring injury performed the Nordic hamstring exercise (NHE) and stiff-leg deadlift (SDL) while BFlh and ST activities were recorded with high-density electromyography (HD-EMG). Normalized activity was calculated from the distal, middle, and proximal regions in the eccentric phase of each exercise. In NHE, ST overall activity was substantially higher than in BFlh (d = 1.06 ± 0.45), compared to trivial differences between muscles in SDL (d = 0.19 ± 0.34). Regional differences were found in NHE for both muscles, with different proximal-distal patterns: The distal region showed the lowest activity level in ST (regional differences, d range = 0.55-1.41) but the highest activity level in BFlh (regional differences, d range = 0.38-1.25). In SDL, regional differences were smaller in both muscles (d range = 0.29-0.67 and 0.16-0.63 in ST and BFlh, respectively) than in NHE. The use of HD-EMG in hamstrings revealed heterogeneous hamstrings activity during typical injury prevention exercises. High-density EMG might be useful in future studies to provide a comprehensive overview of hamstring muscle activity in other exercises and high-injury risk tasks. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. Elbow joint angle and elbow movement velocity estimation using NARX-multiple layer perceptron neural network model with surface EMG time domain parameters.

    PubMed

    Raj, Retheep; Sivanandan, K S

    2017-01-01

    Estimation of elbow dynamics has been the object of numerous investigations. In this work a solution is proposed for estimating elbow movement velocity and elbow joint angle from Surface Electromyography (SEMG) signals. Here the Surface Electromyography signals are acquired from the biceps brachii muscle of human hand. Two time-domain parameters, Integrated EMG (IEMG) and Zero Crossing (ZC), are extracted from the Surface Electromyography signal. The relationship between the time domain parameters, IEMG and ZC with elbow angular displacement and elbow angular velocity during extension and flexion of the elbow are studied. A multiple input-multiple output model is derived for identifying the kinematics of elbow. A Nonlinear Auto Regressive with eXogenous inputs (NARX) structure based multiple layer perceptron neural network (MLPNN) model is proposed for the estimation of elbow joint angle and elbow angular velocity. The proposed NARX MLPNN model is trained using Levenberg-marquardt based algorithm. The proposed model is estimating the elbow joint angle and elbow movement angular velocity with appreciable accuracy. The model is validated using regression coefficient value (R). The average regression coefficient value (R) obtained for elbow angular displacement prediction is 0.9641 and for the elbow anglular velocity prediction is 0.9347. The Nonlinear Auto Regressive with eXogenous inputs (NARX) structure based multiple layer perceptron neural networks (MLPNN) model can be used for the estimation of angular displacement and movement angular velocity of the elbow with good accuracy.

  18. Specific muscle EMG biofeedback for hand dystonia.

    PubMed

    Deepak, K K; Behari, M

    1999-12-01

    Currently available therapies have only limited success in patients having hand dystonia (writer's cramp). We employed specific muscle EMG biofeedback (audio feedback of the EMG from proximal large muscles of the limb that show abnormally high activity during writing) in 10 of 13 consecutive patients (age, 19-62 years; all males) with a duration of illness from 6 months to 8 years. In three patients, biofeedback was not applicable due to lack of abnormal EMG values. Nine patients showed dystonic posture during writing and had hypertrophy of one or more large muscles of the dominant hand. The remaining four patients showed either involvement of small muscles or muscle wasting. Ten patients were given four or more sessions of EMG audio biofeedback from the proximal large limb muscles, which showed maximum EMG activity. They also practiced writing daily with the relaxed limb for 5 to 10 min. Nine patients showed improvement from 37 to 93% in handwriting, alleviation of discomfort, and pain (assessed on a visual analogue scale). One patient did not show any improvement. Thus EMG biofeedback improved the clinical and electromyographic picture in those patients with hand dystonia who showed EMG overactivity of proximal limb muscles during writing. This specific type of EMG biofeedback appears to be a promising tool for hand dystonia and might also be applied to other types of dystonias.

  19. A Practical Strategy for sEMG-Based Knee Joint Moment Estimation During Gait and Its Validation in Individuals With Cerebral Palsy

    PubMed Central

    Kwon, Suncheol; Stanley, Christopher J.; Kim, Jung; Kim, Jonghyun; Damiano, Diane L.

    2013-01-01

    Individuals with cerebral palsy have neurological deficits that may interfere with motor function and lead to abnormal walking patterns. It is important to know the joint moment generated by the patient’s muscles during walking in order to assist the suboptimal gait patterns. In this paper, we describe a practical strategy for estimating the internal moment of a knee joint from surface electromyography (sEMG) and knee joint angle measurements. This strategy requires only isokinetic knee flexion and extension tests to obtain a relationship between the sEMG and the knee internal moment, and it does not necessitate comprehensive laboratory calibration, which typically requires a 3-D motion capture system and ground reaction force plates. Four estimation models were considered based on different assumptions about the functions of the relevant muscles during the isokinetic tests and the stance phase of walking. The performance of the four models was evaluated by comparing the estimated moments with the gold standard internal moment calculated from inverse dynamics. The results indicate that an optimal estimation model can be chosen based on the degree of cocontraction. The estimation error of the chosen model is acceptable (normalized root-mean-squared error: 0.15–0.29, R: 0.71–0.93) compared to previous studies (Doorenbosch and Harlaar, 2003; Doorenbosch and Harlaar, 2004; Doorenbosch, Joosten, and Harlaar, 2005), and this strategy provides a simple and effective solution for estimating knee joint moment from sEMG. PMID:22410952

  20. Evaluation of Feature Extraction and Recognition for Activity Monitoring and Fall Detection Based on Wearable sEMG Sensors.

    PubMed

    Xi, Xugang; Tang, Minyan; Miran, Seyed M; Luo, Zhizeng

    2017-05-27

    As an essential subfield of context awareness, activity awareness, especially daily activity monitoring and fall detection, plays a significant role for elderly or frail people who need assistance in their daily activities. This study investigates the feature extraction and pattern recognition of surface electromyography (sEMG), with the purpose of determining the best features and classifiers of sEMG for daily living activities monitoring and fall detection. This is done by a serial of experiments. In the experiments, four channels of sEMG signal from wireless, wearable sensors located on lower limbs are recorded from three subjects while they perform seven activities of daily living (ADL). A simulated trip fall scenario is also considered with a custom-made device attached to the ankle. With this experimental setting, 15 feature extraction methods of sEMG, including time, frequency, time/frequency domain and entropy, are analyzed based on class separability and calculation complexity, and five classification methods, each with 15 features, are estimated with respect to the accuracy rate of recognition and calculation complexity for activity monitoring and fall detection. It is shown that a high accuracy rate of recognition and a minimal calculation time for daily activity monitoring and fall detection can be achieved in the current experimental setting. Specifically, the Wilson Amplitude (WAMP) feature performs the best, and the classifier Gaussian Kernel Support Vector Machine (GK-SVM) with Permutation Entropy (PE) or WAMP results in the highest accuracy for activity monitoring with recognition rates of 97.35% and 96.43%. For fall detection, the classifier Fuzzy Min-Max Neural Network (FMMNN) has the best sensitivity and specificity at the cost of the longest calculation time, while the classifier Gaussian Kernel Fisher Linear Discriminant Analysis (GK-FDA) with the feature WAMP guarantees a high sensitivity (98.70%) and specificity (98.59%) with a short

  1. Evaluation of Feature Extraction and Recognition for Activity Monitoring and Fall Detection Based on Wearable sEMG Sensors

    PubMed Central

    Xi, Xugang; Tang, Minyan; Miran, Seyed M.; Luo, Zhizeng

    2017-01-01

    As an essential subfield of context awareness, activity awareness, especially daily activity monitoring and fall detection, plays a significant role for elderly or frail people who need assistance in their daily activities. This study investigates the feature extraction and pattern recognition of surface electromyography (sEMG), with the purpose of determining the best features and classifiers of sEMG for daily living activities monitoring and fall detection. This is done by a serial of experiments. In the experiments, four channels of sEMG signal from wireless, wearable sensors located on lower limbs are recorded from three subjects while they perform seven activities of daily living (ADL). A simulated trip fall scenario is also considered with a custom-made device attached to the ankle. With this experimental setting, 15 feature extraction methods of sEMG, including time, frequency, time/frequency domain and entropy, are analyzed based on class separability and calculation complexity, and five classification methods, each with 15 features, are estimated with respect to the accuracy rate of recognition and calculation complexity for activity monitoring and fall detection. It is shown that a high accuracy rate of recognition and a minimal calculation time for daily activity monitoring and fall detection can be achieved in the current experimental setting. Specifically, the Wilson Amplitude (WAMP) feature performs the best, and the classifier Gaussian Kernel Support Vector Machine (GK-SVM) with Permutation Entropy (PE) or WAMP results in the highest accuracy for activity monitoring with recognition rates of 97.35% and 96.43%. For fall detection, the classifier Fuzzy Min-Max Neural Network (FMMNN) has the best sensitivity and specificity at the cost of the longest calculation time, while the classifier Gaussian Kernel Fisher Linear Discriminant Analysis (GK-FDA) with the feature WAMP guarantees a high sensitivity (98.70%) and specificity (98.59%) with a short

  2. Design of microcontroller-based EMG and the analysis of EMG signals.

    PubMed

    Güler, Nihal Fatma; Hardalaç, Firat

    2002-04-01

    In this work, a microcontroller-based EMG designed and tested on 40 patients. When the patients are in rest, the fast Fourier transform (FFT) analysis was applied to EMG signals recorded from right leg peroneal region. The histograms are constructed from the results of the FFT analysis. The analysis results shows that the amplitude of fibrillation potential of the muscle fiber of 30 patients measured from peroneal region is low and the duration is short. This is the reason why the motor nerves degenerated and 10 patients were found to be healthy.

  3. EMG analysis of peroneal and tibialis anterior muscle activity prior to foot contact during functional activities.

    PubMed

    McLoda, T A; Hansen, A J; Birrer, D A

    2004-06-01

    The purpose of this investigation was to determine the pre-activity of the tibialis anterior (TA), peroneus longus (PL), and peroneus brevis (PB) prior to foot contact during three conditions. Twenty-six subjects (age 22 +/- 2 yrs; 15 male, 11 female) with no lower extremity injuries reported for data collection. Data were collected from each subject's dominant leg using surface electromyography (EMG). EMG electrodes were applied over the test muscles using a standard protocol. A heel-toe strike transducer was affixed to the bottom of the subject's shoe. The subject completed two randomized trials of walking on a treadmill (5.6 kph), jogging on a treadmill (9.3 kph) and drop landing from a 38 cm box. Isometric reference positions (IRPs) were recorded for the TA, PL, and PB. Muscle data were normalized to IRPs and the average processed EMG for the 200 ms prior to heel strike during walking and jogging and prior to toe strike when dropping from the box was used for analysis. A one-way repeated measures MANOVA was used to detect differences in pre-activity of the muscles between the three conditions. Univariate tests were used to determine differences for each muscle and Tukey's was applied post hoc to determine individual effect differences. The MANOVA revealed significant differences among the three conditions (F2.50 = 10.770; P < .0005). Average TA activity was significantly higher during jogging (Tukey's; P < .0005). Significant differences existed between each condition for the TA. Average PL and PB activity was significantly higher when drop landing (Tukey's; P < .0005). There was no significant difference between walking and jogging for the PL and PB. The amount of muscle pre-activity occurring before heel or toe strike provides useful information for the examination of reaction times to unexpected inversion during dynamic activities.

  4. Can the calf-raise senior test predict functional fitness in elderly people? A validation study using electromyography, kinematics and strength tests.

    PubMed

    André, Helô-Isa; Carnide, Filomena; Moço, Andreia; Valamatos, Maria-João; Ramalho, Fátima; Santos-Rocha, Rita; Veloso, António

    2018-06-05

    The assessment of the plantar-flexors muscle strength in older adults (OA) is of the utmost importance since they are strongly associated with the performance of fundamental tasks of daily life. The objective was to strengthen the validity of the Calf-Raise-Senior (CRS) test by assessing the biomechanical movement pattern of calf muscles in OA with different levels of functional fitness (FF) and physical activity (PA). Twenty-six OA were assessed with CRS, a FF battery, accelerometry, strength tests, kinematics and electromyography (EMG). OA with the best and worst CRS scores were compared. The association between the scores and EMG pattern of ankle muscles was determined. OA with the best CRS scores presented higher levels of FF, PA, strength, power, speed and range of movement, and a more efficient movement pattern during the test. Subjects who scored more at the CRS test demonstrated the possibility to use a stretch-shortening cycle type of action in the PF muscles to increase power during the movements. OA with different levels of FF can be stratified by the muscular activation pattern of the calf muscles and the scores in CRS test. This study reinforced the validity of CRS for evaluating ankle strength and power in OA. Copyright © 2018 Elsevier Ltd. All rights reserved.

  5. Recognition of Handwriting from Electromyography

    PubMed Central

    Linderman, Michael; Lebedev, Mikhail A.; Erlichman, Joseph S.

    2009-01-01

    Handwriting – one of the most important developments in human culture – is also a methodological tool in several scientific disciplines, most importantly handwriting recognition methods, graphology and medical diagnostics. Previous studies have relied largely on the analyses of handwritten traces or kinematic analysis of handwriting; whereas electromyographic (EMG) signals associated with handwriting have received little attention. Here we show for the first time, a method in which EMG signals generated by hand and forearm muscles during handwriting activity are reliably translated into both algorithm-generated handwriting traces and font characters using decoding algorithms. Our results demonstrate the feasibility of recreating handwriting solely from EMG signals – the finding that can be utilized in computer peripherals and myoelectric prosthetic devices. Moreover, this approach may provide a rapid and sensitive method for diagnosing a variety of neurogenerative diseases before other symptoms become clear. PMID:19707562

  6. Comparison of the effects of mirror therapy and electromyography-triggered neuromuscular stimulation on hand functions in stroke patients: a pilot study.

    PubMed

    Amasyali, Saliha Y; Yaliman, Ayşe

    2016-12-01

    To determine the effectiveness of mirror therapy and electromyography (EMG)-triggered neuromuscular stimulation on improvement of functions of the upper extremity in patients with subacute stroke in comparison with conventional therapy as well as to evaluate the advantage of each treatment over another, we conducted a prospective, randomized, and controlled trial involving 24 patients with ischemic stroke. The mean age and mean time since stroke of the patients were 58.79±11.49 years and 5.25±2.25 months. Patients were assigned randomly to a mirror therapy group (MT group, n=9), which consisted of therapy with a mirror box 5 days/week, 30 min/day, for 3 weeks, an electrostimulation group (ES group, n=7), which consisted of therapy with EMG-triggered stimulation (EMG-stim) of similar duration and frequency of treatment as the MT group, and a control group (n=8). All the groups received conventional physiotherapy for the same period as the MT group. Patients in the MT group practiced their therapy at home after supervised sessions. The Fugl-Meyer scores of the upper extremity, grip force, wrist extension, and Box and Block Test were evaluated at baseline, after treatment, and at 3 months after the treatment. All of these measures were evaluated by a blinded researcher. We found that there was no significant improvement in wrist extension range and grip force in control group. The MT and EMG-stim were effective in increasing the Fugl-Meyer motor scale for upper extremity (MT group: P<0.01), increasing wrist extension range, grip force, and hand dexterity determined by the Box and Block Test (MT group and ES group P<0.05). Furthermore, hand skills were increased significantly in the MT group compared with the ES group at the follow-up assessment (P<0.05). This pilot study suggested that MT was more efficient in improving motor performance than physiotherapy alone. Also, MT may be more useful in improving the hand skills compared with EMG-stim. We assume that this

  7. The Location of Peak Upper Trapezius Muscle Activity During Submaximal Contractions is not Associated With the Location of Myofascial Trigger Points: New Insights Revealed by High-density Surface EMG.

    PubMed

    Barbero, Marco; Falla, Deborah; Mafodda, Luca; Cescon, Corrado; Gatti, Roberto

    2016-12-01

    To apply topographical mapping of the electromyography (EMG) amplitude recorded from the upper trapezius muscle to evaluate the distribution of activity and the location of peak activity during a shoulder elevation task in participants with and without myofascial pain and myofascial trigger points (MTrP) and compare this location with the site of the MTrP. Thirteen participants with myofascial pain and MTrP in the upper trapezius muscle and 12 asymptomatic individuals participated. High-density surface EMG was recorded from the upper trapezius muscle using a matrix of 64 surface electrodes aligned with an anatomic landmark system (ALS). Each participant performed a shoulder elevation task consisting of a series of 30 s ramped contractions to 15% or 60% of their maximal voluntary contraction (MVC) force. Topographical maps of the EMG average rectified value were computed and the peak EMG amplitude during the ramped contractions was identified and its location determined with respect to the ALS. The location of the MTrP was also determined relative to the ALS and Spearman correlation coefficients were used to examine the relationship between MTrP and peak EMG amplitude location. The location of the peak EMG amplitude was significantly (P<0.05) different between groups (participants with pain/MTrP: -0.32±1.2 cm at 15% MVC and -0.35±0.9 cm at 60% MVC relative to the ALS; asymptomatic participants: 1.0±1.3 cm at 15% MVC and 1.3±1.1 cm relative to the ALS). However, no correlation was observed between the position of the MTrP and peak EMG amplitude during the ramped contractions at either force level (15%: rs=0.039, P=0.9; 60%: rs=-0.087, P=0.778). People with myofascial pain and MTrP displayed a caudal shift of the distribution of upper trapezius muscle activity compared with asymptomatic individuals during a submaximal shoulder elevation task. For the first time, we show that the location of peak muscle activity is not associated with the location of the MTrP.

  8. The Assessment of Muscular Effort, Fatigue, and Physiological Adaptation Using EMG and Wavelet Analysis.

    PubMed

    Graham, Ryan B; Wachowiak, Mark P; Gurd, Brendon J

    2015-01-01

    Peroxisome proliferator-activated receptor gamma coactivator 1 alpha (PGC-1α) is a transcription factor co-activator that helps coordinate mitochondrial biogenesis within skeletal muscle following exercise. While evidence gleaned from submaximal exercise suggests that intracellular pathways associated with the activation of PGC-1α, as well as the expression of PGC-1α itself are activated to a greater extent following higher intensities of exercise, we have recently shown that this effect does not extend to supramaximal exercise, despite corresponding increases in muscle activation amplitude measured with electromyography (EMG). Spectral analyses of EMG data may provide a more in-depth assessment of changes in muscle electrophysiology occurring across different exercise intensities, and therefore the goal of the present study was to apply continuous wavelet transforms (CWTs) to our previous data to comprehensively evaluate: 1) differences in muscle electrophysiological properties at different exercise intensities (i.e. 73%, 100%, and 133% of peak aerobic power), and 2) muscular effort and fatigue across a single interval of exercise at each intensity, in an attempt to shed mechanistic insight into our previous observations that the increase in PGC-1α is dissociated from exercise intensity following supramaximal exercise. In general, the CWTs revealed that localized muscle fatigue was only greater than the 73% condition in the 133% exercise intensity condition, which directly matched the work rate results. Specifically, there were greater drop-offs in frequency, larger changes in burst power, as well as greater changes in burst area under this intensity, which were already observable during the first interval. As a whole, the results from the present study suggest that supramaximal exercise causes extreme localized muscular fatigue, and it is possible that the blunted PGC-1α effects observed in our previous study are the result of fatigue-associated increases in

  9. Effect of instructions on EMG during the bench press in trained and untrained males.

    PubMed

    Daniels, Rebecca J; Cook, Summer B

    2017-10-01

    Strength and rehabilitation professionals strive to emphasize certain muscles used during an exercise and it may be possible to alter muscle recruitment strategies with varying instructions. This study aimed to determine whether resistance trained and untrained males could selectively activate the pectoralis major or triceps brachii during the bench press according to various instructions. This study included 13 trained males (21.5±2.9years old, 178.7±7.0cm, 85.7±10.7kg) and 12 untrained males (20.3±1.6years old, 178.8±9.4cm, 74.6±17.3kg). Participants performed a bench press one-repetition maximum (1-RM) test, 3 uninstructed repetitions at 80% 1-RM and two more sets of three repetitions with instructions to isolate the chest or arm muscles. Electromyography (EMG) was obtained from the pectoralis major, anterior deltoid, and the long head and short head of the triceps brachii. Maximum EMG activity normalized to 1-RM for each muscle was averaged over the three repetitions for each set and compared between the uninstructed, chest-instructed and arm-instructed conditions among the groups. The trained participants had a greater 1-RM (126.2±30.6kg) than the untrained participants (61.6±14.8kg) (P<0.01). EMG activity was not different between the groups for any of the instructions (P>0.05). When the group data was combined, short head of the triceps activity was significantly lower in the chest instruction (80.1±19.3%) when compared to the uninstructed (85.6±23.3%; P=0.01) and arm-instructed (86.0±23.2; P=0.01) conditions. It can be concluded that instructions can affect muscle activation during the bench press, and this is not dependent on training status. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Psychophysiological assessment of emotional processing in patients with borderline personality disorder with and without comorbid substance use.

    PubMed

    Baschnagel, Joseph S; Coffey, Scott F; Hawk, Larry W; Schumacher, Julie A; Holloman, Garland

    2013-07-01

    This study assessed physiological measures for the study of emotional dysregulation associated with borderline personality disorder (BPD). Two patient groups, the first comprised of individuals with BPD only (n = 16) and the second, individuals with BPD and co-occurring substance-use disorder (SUD; n = 35), and a group of healthy controls (n = 45) were shown standardized pictures of varying valance and arousal levels. Affective modification of startle eye-blink responses, heart rate, facial electromyography (EMG, including corrugator and zygomatic activity), and skin-conductance responses were collected during picture presentation and during a brief recovery period. Startle data during picture presentation indicated a trend toward the expected increase in startle response magnitude to negative stimuli, to be moderated by group status, with patients with BPD-SUD showing a lack of affective modification and the BPD-only group showing similar affective modification to that of controls. Heart-rate data suggested lower reactivity to negative pictures for both patient groups. Differences in facial EMG responses did not provide a clear pattern, and skin-conductance responses were not significantly different between groups. The data did not suggest differences between groups in recovery from exposure to the emotional stimuli. The startle and heart-rate data suggest a possible hyporeactivity to emotional stimuli in BPD.

  11. Surface electromyography and plantar pressure during walking in young adults with chronic ankle instability.

    PubMed

    Koldenhoven, Rachel M; Feger, Mark A; Fraser, John J; Saliba, Susan; Hertel, Jay

    2016-04-01

    Lateral ankle sprains are common and can manifest into chronic ankle instability (CAI) resulting in altered gait mechanics that may lead to subsequent ankle sprains. Our purpose was to simultaneously analyse muscle activation patterns and plantar pressure distribution during walking in young adults with and without CAI. Seventeen CAI and 17 healthy subjects walked on a treadmill at 4.8 km/h. Plantar pressure measures (pressure-time integral, peak pressure, time to peak pressure, contact area, contact time) of the entire foot and nine specific foot regions and medial-lateral location of centre of pressure (COP) were measured. Surface electromyography (EMG) root mean square (RMS) amplitudes throughout the entire stride cycle and area under RMS curve for 100 ms pre-initial contact (IC) and 200 ms post-IC for anterior tibialis, peroneus longus, medial gastrocnemius, and gluteus medius were collected. The CAI group demonstrated a more lateral COP throughout the stance phase (P < 0.001 and Cohen's d > 0.9 for all 10 comparisons) and significantly increased peak pressure (P = 0.025) and pressure-time integral (P = 0.049) under the lateral forefoot. The CAI group had lower anterior tibialis RMS areas (P < 0.001) and significantly higher peroneus longus, medial gastrocnemius, and gluteus medius RMS areas during 100 ms pre-IC (P < 0.003). The CAI group had higher gluteus medius sEMG amplitudes during the final 50 % of stance and first 25% of swing (P < 0.05). The CAI group had large lateral deviations of their COP location throughout the entire stance phase and increased gluteus medius muscle activation amplitude during late stance through early swing phase. III.

  12. Verbal, Facial and Autonomic Responses to Empathy-Eliciting Film Clips by Disruptive Male Adolescents with High versus Low Callous-Unemotional Traits

    ERIC Educational Resources Information Center

    de Wied, Minet; van Boxtel, Anton; Matthys, Walter; Meeus, Wim

    2012-01-01

    This study examined empathy-related responding in male adolescents with disruptive behavior disorder (DBD), high or low on callous-unemotional (CU) traits. Facial electromyographic (EMG) and heart rate (HR) responses were monitored during exposure to empathy-inducing film clips portraying sadness, anger or happiness. Self-reports were assessed…

  13. Correlation of final evoked potential amplitudes on intraoperative electromyography of the recurrent laryngeal nerve with immediate postoperative vocal fold function after thyroid and parathyroid surgery.

    PubMed

    Genther, Dane J; Kandil, Emad H; Noureldine, Salem I; Tufano, Ralph P

    2014-02-01

    Thyroid and parathyroid surgery are among the most common operations in the United States. Recurrent laryngeal nerve (RLN) injury is an infrequent but potentially detrimental complication. To correlate the final evoked potential amplitudes on intraoperative electromyography (EMG) after stimulation of the RLN with immediate postoperative vocal fold function after thyroid and parathyroid surgery. Retrospective observational study at a tertiary academic medical center. We included 674 patients (with 1000 nerves at risk) undergoing thyroid or parathyroid surgery from July 1, 2008, through June 30, 2012. Thyroid and parathyroid surgery. The association of final evoked potential amplitudes on EMG after thyroid and parathyroid surgery with vocal fold function as determined by postoperative fiberoptic laryngoscopy. Three patients experienced permanent vocal fold paresis (VFP) secondary to intraoperative RLN transection. Of the remaining 997 RLNs at risk, 22 (2.2%) in 20 patients exhibited temporary VFP on fiberoptic laryngoscopy after extubation. Eighteen patients experienced unilateral temporary VFP, and 2 experienced bilateral VFP without the need for tracheostomy or reintubation. Of the 22 RLNs, postdissection EMG amplitudes were less than 200 µV (true-positive findings) in 21 and at least 200 µV (false-negative finding) in 1. Of the 975 RLNs (97.5%) with normal function, postdissection EMG amplitudes were at least 200 µV (true-negative findings) in 967 and less than 200 µV (false-positive findings) in 8. In regard to immediate postoperative VFP, sensitivity, specificity, positive and negative predictive values, and accuracy of postdissection EMG amplitudes of less than 200 µV were 95.5%, 99.2%, 72.4%, 99.9%, and 99.1%, respectively. Intraoperative nerve monitoring of the RLN with EMG provides real-time information regarding neurophysiologic function of the RLN and can predict immediate postoperative VFP reliably when a cutoff of 200 µV is used. The high negative

  14. The effect of isolating the paretic limb on weight-bearing distribution and EMG activity during squats in hemiplegic and healthy individuals.

    PubMed

    Lee, Dong-Kyu; An, Duk-Hyun; Yoo, Won-Gyu; Hwang, Byong-Yong; Kim, Tae-Ho; Oh, Jae-Seop

    2017-05-01

    Neural reorganization for movement therapy after a stroke is thought to be an important mechanism that facilitates motor recovery. However, there is a lack of evidence for the effectiveness of exercise programs in improving the lower limbs. We investigated the immediate effect of isolating the paretic limb using different foot positions ((i) foot parallel; both feet parallel, (ii) foot asymmetry; paretic foot backward by 10 cm, and (iii) foot lifting; nonparetic foot lifting by normalization to 25% of knee height) on weight-bearing distribution and electromyography (EMG) of the thigh muscle during squats. In total, 20 patients with hemiplegia and 16 healthy subjects randomly performed three squat conditions in which the knee joint was flexed to 30°. Weight distribution was measured using the BioRescue system. Muscle activity was measured using a surface EMG system. Patients with hemiplegia exhibited significantly decreased weight bearing on the paretic foot at 0° and 30° knee flexion compared with the nondominant foot of a healthy subject. The muscle activity of the quadriceps was significantly lower in patients with hemiplegia compared to healthy subjects. Weight bearing and EMG activity of the quadriceps femoris on the paretic or nondominant side significantly increased during a knee flexion of 30° with under the foot asymmetry and foot lifting positions compared with the parallel foot position. Isolating the paretic limb using the asymmetric foot positions and lifting of the foot during squats might help patients with hemiplegia to improve weight-bearing and achieve greater activation of the quadriceps muscle in the paretic limb.

  15. Recurrence quantification analysis and support vector machines for golf handicap and low back pain EMG classification.

    PubMed

    Silva, Luís; Vaz, João Rocha; Castro, Maria António; Serranho, Pedro; Cabri, Jan; Pezarat-Correia, Pedro

    2015-08-01

    The quantification of non-linear characteristics of electromyography (EMG) must contain information allowing to discriminate neuromuscular strategies during dynamic skills. There are a lack of studies about muscle coordination under motor constrains during dynamic contractions. In golf, both handicap (Hc) and low back pain (LBP) are the main factors associated with the occurrence of injuries. The aim of this study was to analyze the accuracy of support vector machines SVM on EMG-based classification to discriminate Hc (low and high handicap) and LBP (with and without LPB) in the main phases of golf swing. For this purpose recurrence quantification analysis (RQA) features of the trunk and the lower limb muscles were used to feed a SVM classifier. Recurrence rate (RR) and the ratio between determinism (DET) and RR showed a high discriminant power. The Hc accuracy for the swing, backswing, and downswing were 94.4±2.7%, 97.1±2.3%, and 95.3±2.6%, respectively. For LBP, the accuracy was 96.9±3.8% for the swing, and 99.7±0.4% in the backswing. External oblique (EO), biceps femoris (BF), semitendinosus (ST) and rectus femoris (RF) showed high accuracy depending on the laterality within the phase. RQA features and SVM showed a high muscle discriminant capacity within swing phases by Hc and by LBP. Low back pain golfers showed different neuromuscular coordination strategies when compared with asymptomatic. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. Movement Performance of Human-Robot Cooperation Control Based on EMG-Driven Hill-Type and Proportional Models for an Ankle Power-Assist Exoskeleton Robot.

    PubMed

    Ao, Di; Song, Rong; Gao, JinWu

    2017-08-01

    Although the merits of electromyography (EMG)-based control of powered assistive systems have been certified, the factors that affect the performance of EMG-based human-robot cooperation, which are very important, have received little attention. This study investigates whether a more physiologically appropriate model could improve the performance of human-robot cooperation control for an ankle power-assist exoskeleton robot. To achieve the goal, an EMG-driven Hill-type neuromusculoskeletal model (HNM) and a linear proportional model (LPM) were developed and calibrated through maximum isometric voluntary dorsiflexion (MIVD). The two control models could estimate the real-time ankle joint torque, and HNM is more accurate and can account for the change of the joint angle and muscle dynamics. Then, eight healthy volunteers were recruited to wear the ankle exoskeleton robot and complete a series of sinusoidal tracking tasks in the vertical plane. With the various levels of assist based on the two calibrated models, the subjects were instructed to track the target displayed on the screen as accurately as possible by performing ankle dorsiflexion and plantarflexion. Two measurements, the root mean square error (RMSE) and root mean square jerk (RMSJ), were derived from the assistant torque and kinematic signals to characterize the movement performances, whereas the amplitudes of the recorded EMG signals from the tibialis anterior (TA) and the gastrocnemius (GAS) were obtained to reflect the muscular efforts. The results demonstrated that the muscular effort and smoothness of tracking movements decreased with an increase in the assistant ratio. Compared with LPM, subjects made lower physical efforts and generated smoother movements when using HNM, which implied that a more physiologically appropriate model could enable more natural and human-like human-robot cooperation and has potential value for improvement of human-exoskeleton interaction in future applications.

  17. [Study of ocular surface electromyography signal analysis].

    PubMed

    Zhu, Bei; Qi, Li-Ping

    2009-11-01

    Test ocular surface electromyography signal waves and characteristic parameters to provide effective data for the diagnosis and treatment of ocular myopathy. Surface electromyography signals tests were performed in 140 normal volunteers and 30 patients with ophthalmoplegia. Surface electrodes were attached to medial canthi, lateral canthi and the middle of frontal bone. Then some alternate flashing red lamps were installed on perimeter to reduce the movement of eyeball. The computer hardware, software, and A/D adapter (12 Bit) were used. Sampling frequency could be selected within 40 kHz, frequency of amplifier was 2 kHz, and input short circuit noise was less than 3 microV. For normal volunteers, the ocular surface electromyography signals were regular, and the electric waves were similar between different sex groups and age groups. While for patients with ophthalmoplegia, the wave amplitude of ocular surface electromyography signals were declined or disappeared in the dyskinesia direction. The wave amplitude was related with the degree of pathological process. The characteristic parameters of patients with ophthalmoplegia were higher than normal volunteers. The figures of ocular surface electromyogram obtained from normal volunteers were obviously different with that from patients with ophthalmoplegia. This test can provide reliable quantized data for the diagnosis and treatment of ocular myopathy.

  18. EMG1 is essential for mouse pre-implantation embryo development.

    PubMed

    Wu, Xiaoli; Sandhu, Sumit; Patel, Nehal; Triggs-Raine, Barbara; Ding, Hao

    2010-09-21

    Essential for mitotic growth 1 (EMG1) is a highly conserved nucleolar protein identified in yeast to have a critical function in ribosome biogenesis. A mutation in the human EMG1 homolog causes Bowen-Conradi syndrome (BCS), a developmental disorder characterized by severe growth failure and psychomotor retardation leading to death in early childhood. To begin to understand the role of EMG1 in mammalian development, and how its deficiency could lead to Bowen-Conradi syndrome, we have used mouse as a model. The expression of Emg1 during mouse development was examined and mice carrying a null mutation for Emg1 were generated and characterized. Our studies indicated that Emg1 is broadly expressed during early mouse embryonic development. However, in late embryonic stages and during postnatal development, Emg1 exhibited specific expression patterns. To assess a developmental role for EMG1 in vivo, we exploited a mouse gene-targeting approach. Loss of EMG1 function in mice arrested embryonic development prior to the blastocyst stage. The arrested Emg1-/- embryos exhibited defects in early cell lineage-specification as well as in nucleologenesis. Further, loss of p53, which has been shown to rescue some phenotypes resulting from defects in ribosome biogenesis, failed to rescue the Emg1-/- pre-implantation lethality. Our data demonstrate that Emg1 is highly expressed during mouse embryonic development, and essential for mouse pre-implantation development. The absolute requirement for EMG1 in early embryonic development is consistent with its essential role in yeast. Further, our findings also lend support to the previous study that showed Bowen-Conradi syndrome results from a partial EMG1 deficiency. A complete deficiency would not be expected to be compatible with a live birth.

  19. EMG-Torque Dynamics Change With Contraction Bandwidth.

    PubMed

    Golkar, Mahsa A; Jalaleddini, Kian; Kearney, Robert E

    2018-04-01

    An accurate model for ElectroMyoGram (EMG)-torque dynamics has many uses. One of its applications which has gained high attention among researchers is its use, in estimating the muscle contraction level for the efficient control of prosthesis. In this paper, the dynamic relationship between the surface EMG and torque during isometric contractions at the human ankle was studied using system identification techniques. Subjects voluntarily modulated their ankle torque in dorsiflexion direction, by activating their tibialis anterior muscle, while tracking a pseudo-random binary sequence in a torque matching task. The effects of contraction bandwidth, described by torque spectrum, on EMG-torque dynamics were evaluated by varying the visual command switching time. Nonparametric impulse response functions (IRF) were estimated between the processed surface EMG and torque. It was demonstrated that: 1) at low contraction bandwidths, the identified IRFs had unphysiological anticipatory (i.e., non-causal) components, whose amplitude decreased as the contraction bandwidth increased. We hypothesized that this non-causal behavior arose, because the EMG input contained a component due to feedback from the output torque, i.e., it was recorded from within a closed-loop. Vision was not the feedback source since the non-causal behavior persisted when visual feedback was removed. Repeating the identification using a nonparametric closed-loop identification algorithm yielded causal IRFs at all bandwidths, supporting this hypothesis. 2) EMG-torque dynamics became faster and the bandwidth of system increased as contraction modulation rate increased. Thus, accurate prediction of torque from EMG signals must take into account the contraction bandwidth sensitivity of this system.

  20. Use of surface electromyography in phonation studies: an integrative review

    PubMed Central

    Balata, Patricia Maria Mendes; Silva, Hilton Justino da; Moraes, Kyvia Juliana Rocha de; Pernambuco, Leandro de Araújo; Moraes, Sílvia Regina Arruda de

    2013-01-01

    Summary Introduction: Surface electromyography has been used to assess the extrinsic laryngeal muscles during chewing and swallowing, but there have been few studies assessing these muscles during phonation. Objective: To investigate the current state of knowledge regarding the use of surface electromyography for evaluation of the electrical activity of the extrinsic muscles of the larynx during phonation by means of an integrative review. Method: We searched for articles and other papers in the PubMed, Medline/Bireme, and Scielo databases that were published between 1980 and 2012, by using the following descriptors: surface electromyography and voice, surface electromyography and phonation, and surface electromyography and dysphonia. The articles were selectedon the basis ofinclusion and exclusion criteria. Data Synthesis: This was carried out with a cross critical matrix. We selected 27 papers,i.e., 24 articles and 3 theses. The studies differed methodologically with regards to sample size and investigation techniques, making it difficult to compare them, but showed differences in electrical activity between the studied groups (dysphonicsubjects, non-dysphonicsubjects, singers, and others). Conclusion: Electromyography has clinical applicability when technical precautions with respect to application and analysis are obeyed. However, it is necessary to adopt a universal system of assessment tasks and related measurement techniques to allow comparisons between studies. PMID:25992030

  1. Adaptive neuron-to-EMG decoder training for FES neuroprostheses

    NASA Astrophysics Data System (ADS)

    Ethier, Christian; Acuna, Daniel; Solla, Sara A.; Miller, Lee E.

    2016-08-01

    Objective. We have previously demonstrated a brain-machine interface neuroprosthetic system that provided continuous control of functional electrical stimulation (FES) and restoration of grasp in a primate model of spinal cord injury (SCI). Predicting intended EMG directly from cortical recordings provides a flexible high-dimensional control signal for FES. However, no peripheral signal such as force or EMG is available for training EMG decoders in paralyzed individuals. Approach. Here we present a method for training an EMG decoder in the absence of muscle activity recordings; the decoder relies on mapping behaviorally relevant cortical activity to the inferred EMG activity underlying an intended action. Monkeys were trained at a 2D isometric wrist force task to control a computer cursor by applying force in the flexion, extension, ulnar, and radial directions and execute a center-out task. We used a generic muscle force-to-endpoint force model based on muscle pulling directions to relate each target force to an optimal EMG pattern that attained the target force while minimizing overall muscle activity. We trained EMG decoders during the target hold periods using a gradient descent algorithm that compared EMG predictions to optimal EMG patterns. Main results. We tested this method both offline and online. We quantified both the accuracy of offline force predictions and the ability of a monkey to use these real-time force predictions for closed-loop cursor control. We compared both offline and online results to those obtained with several other direct force decoders, including an optimal decoder computed from concurrently measured neural and force signals. Significance. This novel approach to training an adaptive EMG decoder could make a brain-control FES neuroprosthesis an effective tool to restore the hand function of paralyzed individuals. Clinical implementation would make use of individualized EMG-to-force models. Broad generalization could be achieved by

  2. EMG finger movement classification based on ANFIS

    NASA Astrophysics Data System (ADS)

    Caesarendra, W.; Tjahjowidodo, T.; Nico, Y.; Wahyudati, S.; Nurhasanah, L.

    2018-04-01

    An increase number of people suffering from stroke has impact to the rapid development of finger hand exoskeleton to enable an automatic physical therapy. Prior to the development of finger exoskeleton, a research topic yet important i.e. machine learning of finger gestures classification is conducted. This paper presents a study on EMG signal classification of 5 finger gestures as a preliminary study toward the finger exoskeleton design and development in Indonesia. The EMG signals of 5 finger gestures were acquired using Myo EMG sensor. The EMG signal features were extracted and reduced using PCA. The ANFIS based learning is used to classify reduced features of 5 finger gestures. The result shows that the classification of finger gestures is less than the classification of 7 hand gestures.

  3. Facial expressions and the evolution of the speech rhythm.

    PubMed

    Ghazanfar, Asif A; Takahashi, Daniel Y

    2014-06-01

    In primates, different vocalizations are produced, at least in part, by making different facial expressions. Not surprisingly, humans, apes, and monkeys all recognize the correspondence between vocalizations and the facial postures associated with them. However, one major dissimilarity between monkey vocalizations and human speech is that, in the latter, the acoustic output and associated movements of the mouth are both rhythmic (in the 3- to 8-Hz range) and tightly correlated, whereas monkey vocalizations have a similar acoustic rhythmicity but lack the concommitant rhythmic facial motion. This raises the question of how we evolved from a presumptive ancestral acoustic-only vocal rhythm to the one that is audiovisual with improved perceptual sensitivity. According to one hypothesis, this bisensory speech rhythm evolved through the rhythmic facial expressions of ancestral primates. If this hypothesis has any validity, we expect that the extant nonhuman primates produce at least some facial expressions with a speech-like rhythm in the 3- to 8-Hz frequency range. Lip smacking, an affiliative signal observed in many genera of primates, satisfies this criterion. We review a series of studies using developmental, x-ray cineradiographic, EMG, and perceptual approaches with macaque monkeys producing lip smacks to further investigate this hypothesis. We then explore its putative neural basis and remark on important differences between lip smacking and speech production. Overall, the data support the hypothesis that lip smacking may have been an ancestral expression that was linked to vocal output to produce the original rhythmic audiovisual speech-like utterances in the human lineage.

  4. Inferring Muscle-Tendon Unit Power from Ankle Joint Power during the Push-Off Phase of Human Walking: Insights from a Multiarticular EMG-Driven Model.

    PubMed

    Honert, Eric C; Zelik, Karl E

    2016-01-01

    Inverse dynamics joint kinetics are often used to infer contributions from underlying groups of muscle-tendon units (MTUs). However, such interpretations are confounded by multiarticular (multi-joint) musculature, which can cause inverse dynamics to over- or under-estimate net MTU power. Misestimation of MTU power could lead to incorrect scientific conclusions, or to empirical estimates that misguide musculoskeletal simulations, assistive device designs, or clinical interventions. The objective of this study was to investigate the degree to which ankle joint power overestimates net plantarflexor MTU power during the Push-off phase of walking, due to the behavior of the flexor digitorum and hallucis longus (FDHL)-multiarticular MTUs crossing the ankle and metatarsophalangeal (toe) joints. We performed a gait analysis study on six healthy participants, recording ground reaction forces, kinematics, and electromyography (EMG). Empirical data were input into an EMG-driven musculoskeletal model to estimate ankle power. This model enabled us to parse contributions from mono- and multi-articular MTUs, and required only one scaling and one time delay factor for each subject and speed, which were solved for based on empirical data. Net plantarflexing MTU power was computed by the model and quantitatively compared to inverse dynamics ankle power. The EMG-driven model was able to reproduce inverse dynamics ankle power across a range of gait speeds (R2 ≥ 0.97), while also providing MTU-specific power estimates. We found that FDHL dynamics caused ankle power to slightly overestimate net plantarflexor MTU power, but only by ~2-7%. During Push-off, FDHL MTU dynamics do not substantially confound the inference of net plantarflexor MTU power from inverse dynamics ankle power. However, other methodological limitations may cause inverse dynamics to overestimate net MTU power; for instance, due to rigid-body foot assumptions. Moving forward, the EMG-driven modeling approach presented

  5. Hemifacial Spasm and Neurovascular Compression

    PubMed Central

    Lu, Alex Y.; Yeung, Jacky T.; Gerrard, Jason L.; Michaelides, Elias M.; Sekula, Raymond F.; Bulsara, Ketan R.

    2014-01-01

    Hemifacial spasm (HFS) is characterized by involuntary unilateral contractions of the muscles innervated by the ipsilateral facial nerve, usually starting around the eyes before progressing inferiorly to the cheek, mouth, and neck. Its prevalence is 9.8 per 100,000 persons with an average age of onset of 44 years. The accepted pathophysiology of HFS suggests that it is a disease process of the nerve root entry zone of the facial nerve. HFS can be divided into two types: primary and secondary. Primary HFS is triggered by vascular compression whereas secondary HFS comprises all other causes of facial nerve damage. Clinical examination and imaging modalities such as electromyography (EMG) and magnetic resonance imaging (MRI) are useful to differentiate HFS from other facial movement disorders and for intraoperative planning. The standard medical management for HFS is botulinum neurotoxin (BoNT) injections, which provides low-risk but limited symptomatic relief. The only curative treatment for HFS is microvascular decompression (MVD), a surgical intervention that provides lasting symptomatic relief by reducing compression of the facial nerve root. With a low rate of complications such as hearing loss, MVD remains the treatment of choice for HFS patients as intraoperative technique and monitoring continue to improve. PMID:25405219

  6. Facial Mimicry and Emotion Consistency: Influences of Memory and Context.

    PubMed

    Kirkham, Alexander J; Hayes, Amy E; Pawling, Ralph; Tipper, Steven P

    2015-01-01

    This study investigates whether mimicry of facial emotions is a stable response or can instead be modulated and influenced by memory of the context in which the emotion was initially observed, and therefore the meaning of the expression. The study manipulated emotion consistency implicitly, where a face expressing smiles or frowns was irrelevant and to be ignored while participants categorised target scenes. Some face identities always expressed emotions consistent with the scene (e.g., smiling with a positive scene), whilst others were always inconsistent (e.g., frowning with a positive scene). During this implicit learning of face identity and emotion consistency there was evidence for encoding of face-scene emotion consistency, with slower RTs, a reduction in trust, and inhibited facial EMG for faces expressing incompatible emotions. However, in a later task where the faces were subsequently viewed expressing emotions with no additional context, there was no evidence for retrieval of prior emotion consistency, as mimicry of emotion was similar for consistent and inconsistent individuals. We conclude that facial mimicry can be influenced by current emotion context, but there is little evidence of learning, as subsequent mimicry of emotionally consistent and inconsistent faces is similar.

  7. Analog Front-Ends comparison in the way of a portable, low-power and low-cost EMG controller based on pattern recognition EMBC 2015.

    PubMed

    Mastinu, Enzo; Ortiz-Catalan, Max; Hakansson, Bo

    2015-01-01

    Compact and low-noise Analog Front-Ends (AFEs) are becoming increasingly important for the acquisition of bioelectric signals in portable system. In this work, we compare two popular AFEs available on the market, namely the ADS1299 (Texas Instruments) and the RHA2216 (Intan Technologies). This work develops towards the identification of suitable acquisition modules to design an affordable, reliable and portable device for electromyography (EMG) acquisition and prosthetic control. Device features such as Common Mode Rejection (CMR), Input Referred Noise (IRN) and Signal to Noise Ratio (SNR) were evaluated, as well as the resulting accuracy in myoelectric pattern recognition (MPR) for the decoding of motion intention. Results reported better noise performances and higher MPR accuracy for the ADS1299 and similar SNR values for both devices.

  8. Suppression of stimulus artifact contaminating electrically evoked electromyography.

    PubMed

    Liu, Jie; Li, Sheng; Li, Xiaoyan; Klein, Cliff; Rymer, William Z; Zhou, Ping

    2014-01-01

    Electrical stimulation of muscle or nerve is a very useful technique for understanding of muscle activity and its pathological changes for both diagnostic and therapeutic purposes. During electrical stimulation of a muscle, the recorded M wave is often contaminated by a stimulus artifact. The stimulus artifact must be removed for appropriate analysis and interpretation of M waves. The objective of this study was to develop a novel software based method to remove stimulus artifacts contaminating or superimposing with electrically evoked surface electromyography (EMG) or M wave signals. The multiple stage method uses a series of signal processing techniques, including highlighting and detection of stimulus artifacts using Savitzky-Golay filtering, estimation of the artifact contaminated region with Otsu thresholding, and reconstruction of such region using signal interpolation and smoothing. The developed method was tested using M wave signals recorded from biceps brachii muscles by a linear surface electrode array. To evaluate the performance, a series of semi-synthetic signals were constructed from clean M wave and stimulus artifact recordings with different degrees of overlap between them. The effectiveness of the developed method was quantified by a significant increase in correlation coefficient and a significant decrease in root mean square error between the clean M wave and the reconstructed M wave, compared with those between the clean M wave and the originally contaminated signal. The validity of the developed method was also demonstrated when tested on each channel's M wave recording using a linear electrode array. The developed method can suppress stimulus artifacts contaminating M wave recordings.

  9. Spontaneous Facial Mimicry Is Enhanced by the Goal of Inferring Emotional States: Evidence for Moderation of "Automatic" Mimicry by Higher Cognitive Processes.

    PubMed

    Murata, Aiko; Saito, Hisamichi; Schug, Joanna; Ogawa, Kenji; Kameda, Tatsuya

    2016-01-01

    A number of studies have shown that individuals often spontaneously mimic the facial expressions of others, a tendency known as facial mimicry. This tendency has generally been considered a reflex-like "automatic" response, but several recent studies have shown that the degree of mimicry may be moderated by contextual information. However, the cognitive and motivational factors underlying the contextual moderation of facial mimicry require further empirical investigation. In this study, we present evidence that the degree to which participants spontaneously mimic a target's facial expressions depends on whether participants are motivated to infer the target's emotional state. In the first study we show that facial mimicry, assessed by facial electromyography, occurs more frequently when participants are specifically instructed to infer a target's emotional state than when given no instruction. In the second study, we replicate this effect using the Facial Action Coding System to show that participants are more likely to mimic facial expressions of emotion when they are asked to infer the target's emotional state, rather than make inferences about a physical trait unrelated to emotion. These results provide convergent evidence that the explicit goal of understanding a target's emotional state affects the degree of facial mimicry shown by the perceiver, suggesting moderation of reflex-like motor activities by higher cognitive processes.

  10. Intact mirror mechanisms for automatic facial emotions in children and adolescents with autism spectrum disorder.

    PubMed

    Schulte-Rüther, Martin; Otte, Ellen; Adigüzel, Kübra; Firk, Christine; Herpertz-Dahlmann, Beate; Koch, Iring; Konrad, Kerstin

    2017-02-01

    It has been suggested that an early deficit in the human mirror neuron system (MNS) is an important feature of autism. Recent findings related to simple hand and finger movements do not support a general dysfunction of the MNS in autism. Studies investigating facial actions (e.g., emotional expressions) have been more consistent, however, mostly relied on passive observation tasks. We used a new variant of a compatibility task for the assessment of automatic facial mimicry responses that allowed for simultaneous control of attention to facial stimuli. We used facial electromyography in 18 children and adolescents with Autism spectrum disorder (ASD) and 18 typically developing controls (TDCs). We observed a robust compatibility effect in ASD, that is, the execution of a facial expression was facilitated if a congruent facial expression was observed. Time course analysis of RT distributions and comparison to a classic compatibility task (symbolic Simon task) revealed that the facial compatibility effect appeared early and increased with time, suggesting fast and sustained activation of motor codes during observation of facial expressions. We observed a negative correlation of the compatibility effect with age across participants and in ASD, and a positive correlation between self-rated empathy and congruency for smiling faces in TDC but not in ASD. This pattern of results suggests that basic motor mimicry is intact in ASD, but is not associated with complex social cognitive abilities such as emotion understanding and empathy. Autism Res 2017, 10: 298-310. © 2016 International Society for Autism Research, Wiley Periodicals, Inc. © 2016 International Society for Autism Research, Wiley Periodicals, Inc.

  11. Relationship between grasping force and features of single-channel intramuscular EMG signals.

    PubMed

    Kamavuako, Ernest Nlandu; Farina, Dario; Yoshida, Ken; Jensen, Winnie

    2009-12-15

    The surface electromyographic (sEMG) signal can be used for force prediction and control in prosthetic devices. Because of technological advances on implantable sensors, the use of intramuscular EMG (iEMG) is becoming a potential alternative to sEMG for the control of multiple degrees-of-freedom (DOF). An invasive system is not affected by crosstalk, typical of sEMG, and provides more stable and independent control sites. However, intramuscular recordings provide more local information because of their high selectivity, and may thus be less representative of the global muscle activity with respect to sEMG. This study investigates the capacity of selective single-channel iEMG recordings to represent the grasping force with respect to the use of sEMG with the aim of assessing if iEMG can be an effective method for proportional myoelectric control. sEMG and iEMG were recorded concurrently from 10 subjects who exerted six grasping force profiles from 0 to 25/50N. The linear correlation coefficient between features extracted from iEMG and force was approximately 0.9 and was not significantly different from the degree of correlation between sEMG and force. This result indicates that a selective iEMG recording is representative of the applied grasping force and can be used for proportional control.

  12. An Investigative Redesign of the ECG and EMG Signal Conditioning Circuits for Two-fault Tolerance and Circuit Improvement

    NASA Technical Reports Server (NTRS)

    Obrien, Edward M.

    1991-01-01

    An investigation was undertaken to make the elctrocardiography (ECG) and the electromyography (EMG) signal conditioning circuits two-fault tolerant and to update the circuitry. The present signal conditioning circuits provide at least one level of subject protection against electrical shock hazard but at a level of 100 micro-A (for voltages of up to 200 V). However, it is necessary to provide catastrophic fault tolerance protection for the astronauts and to provide protection at a current level of less that 100 micro-A. For this study, protection at the 10 micro-A level was sought. This is the generally accepted value below which no possibility of microshock exists. Only the possibility of macroshock exists in the case of the signal conditioners. However, this extra amount of protection is desirable. The initial part deals with current limiter circuits followed by an investigation into the signal conditioner specifications and circuit design.

  13. Effects of 8-week sensory electrical stimulation combined with motor training on EEG-EMG coherence and motor function in individuals with stroke.

    PubMed

    Pan, Li-Ling Hope; Yang, Wen-Wen; Kao, Chung-Lan; Tsai, Mei-Wun; Wei, Shun-Hwa; Fregni, Felipe; Chen, Vincent Chiun-Fan; Chou, Li-Wei

    2018-06-15

    The peripheral sensory system is critical to regulating motor plasticity and motor recovery. Peripheral electrical stimulation (ES) can generate constant and adequate sensory input to influence the excitability of the motor cortex. The aim of this proof of concept study was to assess whether ES prior to each hand function training session for eight weeks can better improve neuromuscular control and hand function in chronic stroke individuals and change electroencephalography-electromyography (EEG-EMG) coherence, as compared to the control (sham ES). We recruited twelve subjects and randomly assigned them into ES and control groups. Both groups received 20-minute hand function training twice a week, and the ES group received 40-minute ES on the median nerve of the affected side before each training session. The control group received sham ES. EEG, EMG and Fugl-Meyer Assessment (FMA) were collected at four different time points. The corticomuscular coherence (CMC) in the ES group at fourth weeks was significantly higher (p = 0.004) as compared to the control group. The notable increment of FMA at eight weeks and follow-up was found only in the ES group. The eight-week rehabilitation program that implemented peripheral ES sessions prior to function training has a potential to improve neuromuscular control and hand function in chronic stroke individuals.

  14. Real-time controller for foot-drop correction by using surface electromyography sensor.

    PubMed

    Al Mashhadany, Yousif I; Abd Rahim, Nasrudin

    2013-04-01

    Foot drop is a disease caused mainly by muscle paralysis, which incapacitates the nerves generating the impulses that control feet in a heel strike. The incapacity may stem from lesions that affect the brain, the spinal cord, or peripheral nerves. The foot becomes dorsiflexed, affecting normal walking. A design and analysis of a controller for such legs is the subject of this article. Surface electromyography electrodes are connected to the skin surface of the human muscle and work on the mechanics of human muscle contraction. The design uses real surface electromyography signals for estimation of the joint angles. Various-speed flexions and extensions of the leg were analyzed. The two phases of the design began with surface electromyography of real human leg electromyography signal, which was subsequently filtered, amplified, and normalized to the maximum amplitude. Parameters extracted from the surface electromyography signal were then used to train an artificial neural network for prediction of the joint angle. The artificial neural network design included various-speed identification of the electromyography signal and estimation of the angles of the knee and ankle joints by a recognition process that depended on the parameters of the real surface electromyography signal measured through real movements. The second phase used artificial neural network estimation of the control signal, for calculation of the electromyography signal to be stimulated for the leg muscle to move the ankle joint. Satisfactory simulation (MATLAB/Simulink version 2012a) and implementation results verified the design feasibility.

  15. Paracetamol 325 mg/tramadol 37.5 mg effect on pain during needle electromyography: a double-blind crossover clinical trial.

    PubMed

    Kalantar, Seyed Sadeq; Abbasi, Mehrshad; Faghihi-Kashani, Sara; Majedi, Hossein; Ahmadi, Mona; Agah, Elmira; Tafakhori, Abbas

    2016-12-01

    Needle insertion during electromyography (EMG) may cause varying levels of pain that could lead to inaccurate assessment and premature termination of the procedure. The aim of this study is to compare paracetamol 325 mg/tramadol 37.5 mg with placebo in relieving pain before EMG. This is a randomized, crossover, placebo-controlled, double-blind clinical trial; forty-four healthy individuals, including 27 males with a mean age of 35.3 years (range 18-59 years), entered this study. The needles were inserted unilaterally 2 h after administration of two analgesic tablets of paracetamol 325 mg/tramadol 37.5 mg or two placebo tablets. The pain was scored through a 100-mm visual analog scale (VAS) immediately and 2 h after the procedure. The side effects were also recorded. Within a week, the procedure was repeated on the other upper limb, changing the treatment and placebo. The immediate and 2-h VAS scores were notably lower after administration of treatment compared to placebo (immediate pain: 17.5 ± 12.8 vs. 32.1 ± 16.0, P < 0.001; and 2-h pain: 1.6 ± 5.6 vs. 5.8 ± 7.9, P = 0. 002). There was a higher prevalence of side effects when treatment was used (48 vs. 9 %, P < 0.001). Although most symptoms were mild, transient and resolved without medical interventions, on one occasion a volunteer experienced brief loss of consciousness and one subject had severe vertigo that required hospitalization and fluid therapy. Paracetamol 325 mg/tramadol 37.5 mg administration prior to EMG could effectively alleviate pain. Further application of this medication in patients with neuromuscular disorders would warrant additional clinical trials, particularly considering the adverse events.

  16. A MATLAB-based graphical user interface for the identification of muscular activations from surface electromyography signals.

    PubMed

    Mengarelli, Alessandro; Cardarelli, Stefano; Verdini, Federica; Burattini, Laura; Fioretti, Sandro; Di Nardo, Francesco

    2016-08-01

    In this paper a graphical user interface (GUI) built in MATLAB® environment is presented. This interactive tool has been developed for the analysis of superficial electromyography (sEMG) signals and in particular for the assessment of the muscle activation time intervals. After the signal import, the tool performs a first analysis in a totally user independent way, providing a reliable computation of the muscular activation sequences. Furthermore, the user has the opportunity to modify each parameter of the on/off identification algorithm implemented in the presented tool. The presence of an user-friendly GUI allows the immediate evaluation of the effects that the modification of every single parameter has on the activation intervals recognition, through the real-time updating and visualization of the muscular activation/deactivation sequences. The possibility to accept the initial signal analysis or to modify the on/off identification with respect to each considered signal, with a real-time visual feedback, makes this GUI-based tool a valuable instrument in clinical, research applications and also in an educational perspective.

  17. Effects of Shoulder Flexion Loaded by an Elastic Tubing Band on EMG Activity of the Gluteal Muscles during Squat Exercises

    PubMed Central

    Kang, Min-Hyeok; Jang, Jun-Hyeok; Kim, Tae-Hoon; Oh, Jae-Seop

    2014-01-01

    [Purpose] We investigated the effects of shoulder flexion loaded by an elastic tubing band during squat exercises, by assessing electromyographic activities of the gluteus maximus and gluteus medius. [Subjects] In total, 17 healthy males were recruited. [Methods] Participants performed squat exercises with and without shoulder flexion loaded by a tubing band. Gluteal muscle activities during the downward and upward phases of the squat exercises were recorded using a surface electromyography (EMG) system. The mean electromyographic activities of the gluteal muscles during squat exercises with and without loaded shoulder flexion were compared using the paired t-test. [Results] Electromyographic activities of the gluteus maximus and gluteus medius were greater in both the upward and downward phases of the squat with loaded shoulder flexion. [Conclusions] The combination of squat and loaded shoulder flexion can be an effective exercise for increasing gluteal muscle activity. PMID:25435701

  18. Motion tracking and electromyography-assisted identification of mirror hand contributions to functional near-infrared spectroscopy images acquired during a finger-tapping task performed by children with cerebral palsy.

    PubMed

    Hervey, Nathan; Khan, Bilal; Shagman, Laura; Tian, Fenghua; Delgado, Mauricio R; Tulchin-Francis, Kirsten; Shierk, Angela; Roberts, Heather; Smith, Linsley; Reid, Dahlia; Clegg, Nancy J; Liu, Hanli; MacFarlane, Duncan; Alexandrakis, George

    2014-10-01

    Recent studies have demonstrated functional near-infrared spectroscopy (fNIRS) to be a viable and sensitive method for imaging sensorimotor cortex activity in children with cerebral palsy (CP). However, during unilateral finger tapping, children with CP often exhibit unintended motions in the nontapping hand, known as mirror motions, which confuse the interpretation of resulting fNIRS images. This work presents a method for separating some of the mirror motion contributions to fNIRS images and demonstrates its application to fNIRS data from four children with CP performing a finger-tapping task with mirror motions. Finger motion and arm muscle activity were measured simultaneously with fNIRS signals using motion tracking and electromyography (EMG), respectively. Subsequently, subject-specific regressors were created from the motion capture or EMG data and independent component analysis was combined with a general linear model to create an fNIRS image representing activation due to the tapping hand and one image representing activation due to the mirror hand. The proposed method can provide information on how mirror motions contribute to fNIRS images, and in some cases, it helps remove mirror motion contamination from the tapping hand activation images.

  19. Motion tracking and electromyography-assisted identification of mirror hand contributions to functional near-infrared spectroscopy images acquired during a finger-tapping task performed by children with cerebral palsy

    PubMed Central

    Hervey, Nathan; Khan, Bilal; Shagman, Laura; Tian, Fenghua; Delgado, Mauricio R.; Tulchin-Francis, Kirsten; Shierk, Angela; Roberts, Heather; Smith, Linsley; Reid, Dahlia; Clegg, Nancy J.; Liu, Hanli; MacFarlane, Duncan; Alexandrakis, George

    2014-01-01

    Abstract. Recent studies have demonstrated functional near-infrared spectroscopy (fNIRS) to be a viable and sensitive method for imaging sensorimotor cortex activity in children with cerebral palsy (CP). However, during unilateral finger tapping, children with CP often exhibit unintended motions in the nontapping hand, known as mirror motions, which confuse the interpretation of resulting fNIRS images. This work presents a method for separating some of the mirror motion contributions to fNIRS images and demonstrates its application to fNIRS data from four children with CP performing a finger-tapping task with mirror motions. Finger motion and arm muscle activity were measured simultaneously with fNIRS signals using motion tracking and electromyography (EMG), respectively. Subsequently, subject-specific regressors were created from the motion capture or EMG data and independent component analysis was combined with a general linear model to create an fNIRS image representing activation due to the tapping hand and one image representing activation due to the mirror hand. The proposed method can provide information on how mirror motions contribute to fNIRS images, and in some cases, it helps remove mirror motion contamination from the tapping hand activation images. PMID:26157980

  20. Long-term effect of prednisolone on functional blink recovery after transient peripheral facial motor paralysis.

    PubMed

    VanderWerf, Frans; Reits, Dik; Metselaar, Mick; De Zeeuw, Chris I

    2012-03-01

    To determine the functional recovery in patients with severe transient peripheral facial motor paralysis (Bell palsy). Prospective controlled trial. Academic medical center. Blink recovery was studied in 2 groups of severely affected Bell palsy patients during a follow-up period of 84 weeks. The patients in one group received prednisolone within the first week after the onset of symptoms. No medication was given to the other group. A control group of healthy subjects was also included. Simultaneous orbicularis oculi muscle activity and eyelid kinematics were recorded by surface electromyographic (EMG) recording and eyelid search coils, respectively. At the beginning of the paralysis, very little integrated orbicularis oculi muscle activity and eyelid movement was measured at the palsied side of the face. Thirteen weeks later, the integrated orbicularis oculi EMG and functional blink recovery gradually improved until 39 weeks. Beyond, only the integrated orbicularis oculi EMG slightly increased. At 84 weeks, the integrated orbicularis oculi EMG was significantly larger in the prednisolone group compared with the control group. The integrated EMG of the nonmedicated group recovered to normal values. Curiously enough, the functional blink recovery at the palsied side remained reduced to 64% compared with the healthy controls in the prednisolone-treated group and to 36% in the nonmedicated group. The authors demonstrate that prednisolone significantly increased the orbicularis oculi muscle activity and significantly improved functional blink recovery in severely affected Bell palsy patients. However, the increase of muscle activity was insufficient to restore functional blinking to normal values.

  1. Laryngeal Electromyography for Prognosis of Vocal Fold Paralysis.

    PubMed

    Pardo-Maza, Adriana; García-Lopez, Isabel; Santiago-Pérez, Susana; Gavilán, Javier

    2017-01-01

    This study aimed to determine the value of laryngeal electromyography in the prognosis of vocal fold paralysis. This is a retrospective descriptive study. This study included 80 patients diagnosed with unilateral or bilateral vocal fold paralysis on flexible laryngoscopy between 2002 and 2014 in a tertiary medical center. Laryngeal electromyography using a standardized protocol was performed; the outcome measures were classified and analyzed into two groups according to the degree of injury. Group 1 included patients with mild to moderate injury, and group 2 included patients with severe to complete injury. Prognosis was correlated with vocal fold motion recovery status with a minimum of 6 months of follow-up since the symptoms onset using positive and negative predictive values. Sixty patients showed acute or chronic recurrent laryngeal neuropathy in laryngeal electromyography. Twelve of 41 patients included in group 1 recovered motion, and 30 of 35 patients included in group 2 did not recover, resulting in 88.2% of positive predictive value and 35.7% of negative predictive value. Our data confirm that laryngeal electromyography is a useful clinical tool in predicting poor recovery in patients with vocal fold paralysis. It allows identification of candidates for early intervention. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  2. Electromyographic Control of a Hands-Free Electrolarynx Using Neck Strap Muscles

    ERIC Educational Resources Information Center

    Kubert, Heather L.; Stepp, Cara E.; Zeitels, Steven M.; Gooey, John E.; Walsh, Michael J.; Prakash, S. R.; Hillman, Robert E.; Heaton, James T.

    2009-01-01

    Three individuals with total laryngectomy were studied for their ability to control a hands-free electrolarynx (EL) using neck surface electromyography (EMG) for on/off and pitch modulation. The laryngectomy surgery of participants was modified to preserve neck strap musculature for EMG-based EL control (EMG-EL), with muscles on one side…

  3. Development of an EMG-ACC-Based Upper Limb Rehabilitation Training System.

    PubMed

    Ling Liu; Xiang Chen; Zhiyuan Lu; Shuai Cao; De Wu; Xu Zhang

    2017-03-01

    This paper focuses on the development of an upper limb rehabilitation training system designed for use by children with cerebral palsy (CP). It attempts to meet the requirements of in-home training by taking advantage of the combination of portable accelerometers (ACC) and surface electromyography (SEMG) sensors worn on the upper limb to capture functional movements. In the proposed system, the EMG-ACC acquisition device works essentially as wireless game controller, and three rehabilitation games were designed for improving upper limb motor function under a clinician's guidance. The games were developed on the Android platform based on a physical engine called Box2D. The results of a system performance test demonstrated that the developed games can respond to the upper limb actions within 210 ms. Positive questionnaire feedbacks from twenty CP subjects who participated in the game test verified both the feasibility and usability of the system. Results of a long-term game training conducted with three CP subjects demonstrated that CP patients could improve in their game performance through repetitive training, and persistent training was needed to improve and enhance the rehabilitation effect. According to our experimental results, the novel multi-feedback SEMG-ACC-based user interface improved the users' initiative and performance in rehabilitation training.

  4. Modeling Nonlinear Errors in Surface Electromyography Due To Baseline Noise: A New Methodology

    PubMed Central

    Law, Laura Frey; Krishnan, Chandramouli; Avin, Keith

    2010-01-01

    The surface electromyographic (EMG) signal is often contaminated by some degree of baseline noise. It is customary for scientists to subtract baseline noise from the measured EMG signal prior to further analyses based on the assumption that baseline noise adds linearly to the observed EMG signal. The stochastic nature of both the baseline and EMG signal, however, may invalidate this assumption. Alternately, “true” EMG signals may be either minimally or nonlinearly affected by baseline noise. This information is particularly relevant at low contraction intensities when signal-to-noise ratios (SNR) may be lowest. Thus, the purpose of this simulation study was to investigate the influence of varying levels of baseline noise (approximately 2 – 40 % maximum EMG amplitude) on mean EMG burst amplitude and to assess the best means to account for signal noise. The simulations indicated baseline noise had minimal effects on mean EMG activity for maximum contractions, but increased nonlinearly with increasing noise levels and decreasing signal amplitudes. Thus, the simple baseline noise subtraction resulted in substantial error when estimating mean activity during low intensity EMG bursts. Conversely, correcting EMG signal as a nonlinear function of both baseline and measured signal amplitude provided highly accurate estimates of EMG amplitude. This novel nonlinear error modeling approach has potential implications for EMG signal processing, particularly when assessing co-activation of antagonist muscles or small amplitude contractions where the SNR can be low. PMID:20869716

  5. Customized Interactive Robotic Treatment for Stroke: EMG-Triggered Therapy

    PubMed Central

    Dipietro, Laura; Ferraro, Mark; Palazzolo, Jerome Joseph; Krebs, Hermano Igo; Volpe, Bruce T.; Hogan, Neville

    2009-01-01

    A system for electromyographic (EMG) triggering of robot-assisted therapy (dubbed the EMG game) for stroke patients is presented. The onset of a patient’s attempt to move is detected by monitoring EMG in selected muscles, whereupon the robot assists her or him to perform point-to-point movements in a horizontal plane. Besides delivering customized robot-assisted therapy, the system can record signals that may be useful to better understand the process of recovery from stroke. Preliminary experiments aimed at testing the proposed system and gaining insight into the potential of EMG-triggered, robot-assisted therapy are reported. PMID:16200756

  6. Analysis of the sEMG/force relationship using HD-sEMG technique and data fusion: A simulation study.

    PubMed

    Al Harrach, Mariam; Carriou, Vincent; Boudaoud, Sofiane; Laforet, Jeremy; Marin, Frederic

    2017-04-01

    The relationship between the surface Electromyogram (sEMG) signal and the force of an individual muscle is still ambiguous due to the complexity of experimental evaluation. However, understanding this relationship should be useful for the assessment of neuromuscular system in healthy and pathological contexts. In this study, we present a global investigation of the factors governing the shape of this relationship. Accordingly, we conducted a focused sensitivity analysis of the sEMG/force relationship form with respect to neural, functional and physiological parameters variation. For this purpose, we used a fast generation cylindrical model for the simulation of an 8×8 High Density-sEMG (HD-sEMG) grid and a twitch based force model for the muscle force generation. The HD-sEMG signals as well as the corresponding force signals were simulated in isometric non-fatiguing conditions and were based on the Biceps Brachii (BB) muscle properties. A total of 10 isometric constant contractions of 5s were simulated for each configuration of parameters. The Root Mean Squared (RMS) value was computed in order to quantify the sEMG amplitude. Then, an image segmentation method was used for data fusion of the 8×8 RMS maps. In addition, a comparative study between recent modeling propositions and the model proposed in this study is presented. The evaluation was made by computing the Normalized Root Mean Squared Error (NRMSE) of their fitting to the simulated relationship functions. Our results indicated that the relationship between the RMS (mV) and muscle force (N) can be modeled using a 3rd degree polynomial equation. Moreover, it appears that the obtained coefficients are patient-specific and dependent on physiological, anatomical and neural parameters. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Evaluation of neuromuscular activity in patients with obstructive sleep apnea using chin surface electromyography of polysomnography.

    PubMed

    Yin, Guo-ping; Ye, Jing-ying; Han, De-min; Wang, Xiao-yi; Zhang, Yu-huan; Li, Yan-ru

    2013-01-01

    It is believed that defects in upper airway neuromuscular control play a role in sleep apnea pathogenesis. Currently, there is no simple and non-invasive method for evaluating neuromuscular activity for the purpose of screening in patients with obstructive sleep apnea. This study was designed to assess the validity of chin surface electromyography of routine polysomnography in evaluating the neuromuscular activity of obstructive sleep apnea subjects and probe the neuromuscular contribution in the pathogenesis of the condition. The chin surface electromyography of routine polysomnography during normal breathing and obstructive apnea were quantified in 36 male patients with obstructive sleep apnea. The change of chin surface electromyography from normal breathing to obstructive apnea was expressed as the percent compensated electromyography value, where the percent compensated electromyography value = (normal breath surface electromyography - apnea surface electromyography)/normal breath surface electromyography, and the percent compensated electromyography values among subjects were compared. The relationship between sleep apnea related parameters and the percent compensated electromyography value was examined. The percent compensated electromyography value of the subjects varied from 1% to 90% and had a significant positive correlation with apnea hypopnea index (R(2) = 0.382, P < 0.001). Recording and analyzing chin surface electromyography by routine polysomnography is a valid way of screening the neuromuscular activity in patients with obstructive sleep apnea. The neuromuscular contribution is different among subjects with obstructive sleep apnea.

  8. Laryngeal Electromyography is Helpful for Cardiovocal Syndrome.

    PubMed

    Akbulut, Sevtap; Inan, Rahsan; Demir, Mehmet Gökhan; Cakan, Dogan

    2016-01-01

    Laryngeal electromyography is used in the evaluation of vocal cord paralysis to confirm the diagnosis, to guide the diagnostic work-up for etiology, to provide prognostic information and to help choose the correct treatment for the patient. Cardiovocal syndrome is characterised by vocal cord paralysis due to a cardiovascular disease. A wide spectrum of conditions can result in this syndrome. Here we present a case of cardiovocal syndrome in association with primary pulmonary hypertension. Laryngeal electromyography was used to guide the work-up of differential diagnosis and also for further intervention with respect to vocal cord paralysis in this patient.

  9. [Electromyography of the perineum. Demonstration of the method].

    PubMed

    Plotti, G; Palla, G P; Romanini, C; Piscicelli, U; Bompiani, A

    1981-05-12

    The Authors, by means of surface E.M.G. have investigated the perineal potentials. The choice of surface E.M.G. is due to the good acceptance of the method by the patients, as it does not interfere with muscular activity and mental concentration, which are fundamental for a good application of R.A.T.

  10. The effect of movement and load on the dynamic coupling of abdominal electromyography.

    PubMed

    King, Adam C

    2018-05-14

    This study investigated the degree of neural coupling in abdominal muscle activity and whether the task constraints of movement and load altered the coupling within three muscle pairings. Nineteen young, physically-active individuals performed sit-up and reverse crunch movements in bodyweight (BW) and loaded (+4.54 kg) conditions. Surface electromyography (sEMG) was recorded from the rectus abdominus (RA), external oblique (EO), and transverse abdominus (TA) muscles. Linear (correlation coefficient) and non-linear (Cross-Approximate Entropy) measurements evaluated the degree of couplings across three muscle pairings. Compared to a resting coupling state, most conditions showed evidence of coupling. The linear coupling showed greater coupling compared to the resting state. Dynamic coupling showed lower degrees of coupling for the RA-EO and RA-TA pairings but stronger coupling for the EO-TA pairing with the sit-up movement exhibiting lower Cross-ApEn (higher dynamic coupling) than the reverse crunch. The results provide preliminary evidence of coupling in abdominal muscle activity that was influenced by movement, but not load. The functional roles of the RA (prime mover), EO and TA (stabilizers) muscles may have influenced the degree of coupling and future investigations are needed to better understand the coupling of abdominal muscle activity. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Suppression of Stimulus Artifact Contaminating Electrically Evoked Electromyography

    PubMed Central

    Liu, Jie; Li, Sheng; Li, Xiaoyan; Klein, Cliff; Rymer, William Z.; Zhou, Ping

    2013-01-01

    Background Electrical stimulation of muscle or nerve is a very useful technique for understanding of muscle activity and its pathological changes for both diagnostic and therapeutic purposes. During electrical stimulation of a muscle, the recorded M wave is often contaminated by a stimulus artifact. The stimulus artifact must be removed for appropriate analysis and interpretation of M waves. Objectives The objective of this study was to develop a novel software based method to remove stimulus artifacts contaminating or superimposing with electrically evoked surface electromyography (EMG) or M wave signals. Methods The multiple stage method uses a series of signal processing techniques, including highlighting and detection of stimulus artifacts using the Savitzky-Golay filtering, estimation of the artifact contaminated region with the Otsu thresholding, and reconstruction of such region using signal interpolation and smoothing. The developed method was tested using M wave signals recorded from biceps brachii muscles by a linear surface electrode array. To evaluate the performance, a series of semi-synthetic signals were constructed from clean M wave and stimulus artifact recordings with different degrees of overlap between them. Results The effectiveness of the developed method was quantified by a significant increase in correlation coefficient and a significant decrease in root mean square error between the clean M wave and the reconstructed M wave, compared with those between the clean M wave and the originally contaminated signal. The validity of the developed method was also demonstrated when tested on each channel’s M wave recording using the linear electrode array. Conclusions The developed method can suppress stimulus artifacts contaminating M wave recordings. PMID:24419021

  12. Emotional effects of startling background music during reading news reports: The moderating influence of dispositional BIS and BAS sensitivities.

    PubMed

    Ravaja, Niklas; Kallinen, Kari

    2004-07-01

    We examined the moderating influence of dispositional behavioral inhibition system (BIS) and behavioral activation system (BAS) sensitivities on the relationship of startling background music with emotion-related subjective and physiological responses elicited during reading news reports, and with memory performance among 26 adult men and women. Physiological parameters measured were respiratory sinus arrhythmia (RSA), electrodermal activity (EDA), and facial electromyography (EMG). The results showed that, among high BAS individuals, news stories with startling background music were rated as more interesting and elicited higher zygomatic EMG activity and RSA than news stories with non-startling music. Among low BAS individuals, news stories with startling background music were rated as less pleasant and more arousing and prompted higher EDA. No BIS-related effects or effects on memory were found. Startling background music may have adverse (e.g., negative arousal) or beneficial effects (e.g., a positive emotional state and stronger positive engagement) depending on dispositional BAS sensitivity of an individual. Actual or potential applications of this research include the personalization of media presentations when using modern media and communications technologies.

  13. The extraction of neural strategies from the surface EMG: an update

    PubMed Central

    Merletti, Roberto; Enoka, Roger M.

    2014-01-01

    A surface EMG signal represents the linear transformation of motor neuron discharge times by the compound action potentials of the innervated muscle fibers and is often used as a source of information about neural activation of muscle. However, retrieving the embedded neural code from a surface EMG signal is extremely challenging. Most studies use indirect approaches in which selected features of the signal are interpreted as indicating certain characteristics of the neural code. These indirect associations are constrained by limitations that have been detailed previously (Farina D, Merletti R, Enoka RM. J Appl Physiol 96: 1486–1495, 2004) and are generally difficult to overcome. In an update on these issues, the current review extends the discussion to EMG-based coherence methods for assessing neural connectivity. We focus first on EMG amplitude cancellation, which intrinsically limits the association between EMG amplitude and the intensity of the neural activation and then discuss the limitations of coherence methods (EEG-EMG, EMG-EMG) as a way to assess the strength of the transmission of synaptic inputs into trains of motor unit action potentials. The debated influence of rectification on EMG spectral analysis and coherence measures is also discussed. Alternatively, there have been a number of attempts to identify the neural information directly by decomposing surface EMG signals into the discharge times of motor unit action potentials. The application of this approach is extremely powerful, but validation remains a central issue. PMID:25277737

  14. A Systematic Review of Electromyography Studies in Normal Shoulders to Inform Postoperative Rehabilitation Following Rotator Cuff Repair.

    PubMed

    Edwards, Peter K; Ebert, Jay R; Littlewood, Chris; Ackland, Tim; Wang, Allan

    2017-12-01

    Study Design Systematic review. Background Electromyography (EMG) has previously been used to guide postoperative rehabilitation progression following rotator cuff repair to prevent deleterious loading of early surgical repair. Objective To review the current literature investigating EMG during rehabilitation exercises in normal shoulders, and to identify exercises that meet a cut point of 15% maximal voluntary isometric contraction (MVIC) or less and are unlikely to result in excessive loading in the early postoperative stages. Methods An electronic search of MEDLINE via Ovid, Embase, CINAHL, SPORTDiscus, PubMed, and the Cochrane Library for all years up to June 2016 was performed. Studies were selected in relation to predefined selection criteria. Pooled mean MVICs were reported and classified as low (0%-15% MVIC), low to moderate (16%-20% MVIC), moderate (21%-40% MVIC), high (41%-60% MVIC), and very high (greater than 60% MVIC). Results A search identified 2159 studies. After applying the selection criteria, 20 studies were included for quality assessment, data extraction, and data synthesis. In total, 43 exercises spanning passive range of motion, active-assisted range of motion, and strengthening exercises were evaluated. Out of 13 active-assisted exercises, 9 were identified as suitable (15% MVIC or less) to load the supraspinatus and 10 as suitable to load the infraspinatus early after surgery. All exercises were placed in a theoretical-continuum model, by which general recommendations could be made for prescription in patients post rotator cuff repair. Conclusion This review identified passive and active-assisted exercises that may be appropriate in the early stages after rotator cuff repair. J Orthop Sports Phys Ther 2017;47(12):931-944. Epub 13 Jul 2017. doi:10.2519/jospt.2017.7271.

  15. Observation and imitation of actions performed by humans, androids, and robots: an EMG study

    PubMed Central

    Hofree, Galit; Urgen, Burcu A.; Winkielman, Piotr; Saygin, Ayse P.

    2015-01-01

    Understanding others’ actions is essential for functioning in the physical and social world. In the past two decades research has shown that action perception involves the motor system, supporting theories that we understand others’ behavior via embodied motor simulation. Recently, empirical approach to action perception has been facilitated by using well-controlled artificial stimuli, such as robots. One broad question this approach can address is what aspects of similarity between the observer and the observed agent facilitate motor simulation. Since humans have evolved among other humans and animals, using artificial stimuli such as robots allows us to probe whether our social perceptual systems are specifically tuned to process other biological entities. In this study, we used humanoid robots with different degrees of human-likeness in appearance and motion along with electromyography (EMG) to measure muscle activity in participants’ arms while they either observed or imitated videos of three agents produce actions with their right arm. The agents were a Human (biological appearance and motion), a Robot (mechanical appearance and motion), and an Android (biological appearance and mechanical motion). Right arm muscle activity increased when participants imitated all agents. Increased muscle activation was found also in the stationary arm both during imitation and observation. Furthermore, muscle activity was sensitive to motion dynamics: activity was significantly stronger for imitation of the human than both mechanical agents. There was also a relationship between the dynamics of the muscle activity and motion dynamics in stimuli. Overall our data indicate that motor simulation is not limited to observation and imitation of agents with a biological appearance, but is also found for robots. However we also found sensitivity to human motion in the EMG responses. Combining data from multiple methods allows us to obtain a more complete picture of action

  16. Use of GDNF-Releasing Nanofiber Nerve Guide Conduits for the Repair of Conus Medullaris/Cauda Equina Injury in the Nonhuman Primate

    DTIC Science & Technology

    2013-10-01

    Electromyography (EMG) recordings of the external anal sphincter were obtained pre- operatively as baseline records. The external anal sphincter muscle was chosen...Lee U, Chang HH, Christe KL, Havton LA. Evoked voiding contractions and corresponding urethral sphincter electromyography in non-human primates differ

  17. EOG-sEMG Human Interface for Communication

    PubMed Central

    Tamura, Hiroki; Yan, Mingmin; Sakurai, Keiko; Tanno, Koichi

    2016-01-01

    The aim of this study is to present electrooculogram (EOG) and surface electromyogram (sEMG) signals that can be used as a human-computer interface. Establishing an efficient alternative channel for communication without overt speech and hand movements is important for increasing the quality of life for patients suffering from amyotrophic lateral sclerosis, muscular dystrophy, or other illnesses. In this paper, we propose an EOG-sEMG human-computer interface system for communication using both cross-channels and parallel lines channels on the face with the same electrodes. This system could record EOG and sEMG signals as “dual-modality” for pattern recognition simultaneously. Although as much as 4 patterns could be recognized, dealing with the state of the patients, we only choose two classes (left and right motion) of EOG and two classes (left blink and right blink) of sEMG which are easily to be realized for simulation and monitoring task. From the simulation results, our system achieved four-pattern classification with an accuracy of 95.1%. PMID:27418924

  18. EOG-sEMG Human Interface for Communication.

    PubMed

    Tamura, Hiroki; Yan, Mingmin; Sakurai, Keiko; Tanno, Koichi

    2016-01-01

    The aim of this study is to present electrooculogram (EOG) and surface electromyogram (sEMG) signals that can be used as a human-computer interface. Establishing an efficient alternative channel for communication without overt speech and hand movements is important for increasing the quality of life for patients suffering from amyotrophic lateral sclerosis, muscular dystrophy, or other illnesses. In this paper, we propose an EOG-sEMG human-computer interface system for communication using both cross-channels and parallel lines channels on the face with the same electrodes. This system could record EOG and sEMG signals as "dual-modality" for pattern recognition simultaneously. Although as much as 4 patterns could be recognized, dealing with the state of the patients, we only choose two classes (left and right motion) of EOG and two classes (left blink and right blink) of sEMG which are easily to be realized for simulation and monitoring task. From the simulation results, our system achieved four-pattern classification with an accuracy of 95.1%.

  19. Spontaneous Facial Mimicry Is Enhanced by the Goal of Inferring Emotional States: Evidence for Moderation of “Automatic” Mimicry by Higher Cognitive Processes

    PubMed Central

    Murata, Aiko; Saito, Hisamichi; Schug, Joanna; Ogawa, Kenji; Kameda, Tatsuya

    2016-01-01

    A number of studies have shown that individuals often spontaneously mimic the facial expressions of others, a tendency known as facial mimicry. This tendency has generally been considered a reflex-like “automatic” response, but several recent studies have shown that the degree of mimicry may be moderated by contextual information. However, the cognitive and motivational factors underlying the contextual moderation of facial mimicry require further empirical investigation. In this study, we present evidence that the degree to which participants spontaneously mimic a target’s facial expressions depends on whether participants are motivated to infer the target’s emotional state. In the first study we show that facial mimicry, assessed by facial electromyography, occurs more frequently when participants are specifically instructed to infer a target’s emotional state than when given no instruction. In the second study, we replicate this effect using the Facial Action Coding System to show that participants are more likely to mimic facial expressions of emotion when they are asked to infer the target’s emotional state, rather than make inferences about a physical trait unrelated to emotion. These results provide convergent evidence that the explicit goal of understanding a target’s emotional state affects the degree of facial mimicry shown by the perceiver, suggesting moderation of reflex-like motor activities by higher cognitive processes. PMID:27055206

  20. Comparison of algorithms to quantify muscle fatigue in upper limb muscles based on sEMG signals.

    PubMed

    Kahl, Lorenz; Hofmann, Ulrich G

    2016-11-01

    This work compared the performance of six different fatigue detection algorithms quantifying muscle fatigue based on electromyographic signals. Surface electromyography (sEMG) was obtained by an experiment from upper arm contractions at three different load levels from twelve volunteers. Fatigue detection algorithms mean frequency (MNF), spectral moments ratio (SMR), the wavelet method WIRM1551, sample entropy (SampEn), fuzzy approximate entropy (fApEn) and recurrence quantification analysis (RQA%DET) were calculated. The resulting fatigue signals were compared considering the disturbances incorporated in fatiguing situations as well as according to the possibility to differentiate the load levels based on the fatigue signals. Furthermore we investigated the influence of the electrode locations on the fatigue detection quality and whether an optimized channel set is reasonable. The results of the MNF, SMR, WIRM1551 and fApEn algorithms fell close together. Due to the small amount of subjects in this study significant differences could not be found. In terms of disturbances the SMR algorithm showed a slight tendency to out-perform the others. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.