Sample records for facilitating arrhythmia simulation

  1. Facilitating arrhythmia simulation: the method of quantitative cellular automata modeling and parallel running

    PubMed Central

    Zhu, Hao; Sun, Yan; Rajagopal, Gunaretnam; Mondry, Adrian; Dhar, Pawan

    2004-01-01

    Background Many arrhythmias are triggered by abnormal electrical activity at the ionic channel and cell level, and then evolve spatio-temporally within the heart. To understand arrhythmias better and to diagnose them more precisely by their ECG waveforms, a whole-heart model is required to explore the association between the massively parallel activities at the channel/cell level and the integrative electrophysiological phenomena at organ level. Methods We have developed a method to build large-scale electrophysiological models by using extended cellular automata, and to run such models on a cluster of shared memory machines. We describe here the method, including the extension of a language-based cellular automaton to implement quantitative computing, the building of a whole-heart model with Visible Human Project data, the parallelization of the model on a cluster of shared memory computers with OpenMP and MPI hybrid programming, and a simulation algorithm that links cellular activity with the ECG. Results We demonstrate that electrical activities at channel, cell, and organ levels can be traced and captured conveniently in our extended cellular automaton system. Examples of some ECG waveforms simulated with a 2-D slice are given to support the ECG simulation algorithm. A performance evaluation of the 3-D model on a four-node cluster is also given. Conclusions Quantitative multicellular modeling with extended cellular automata is a highly efficient and widely applicable method to weave experimental data at different levels into computational models. This process can be used to investigate complex and collective biological activities that can be described neither by their governing differentiation equations nor by discrete parallel computation. Transparent cluster computing is a convenient and effective method to make time-consuming simulation feasible. Arrhythmias, as a typical case, can be effectively simulated with the methods described. PMID:15339335

  2. Effect of Cardiac Arrhythmia Simulation on Nursing Students' Knowledge Acquisition and Retention.

    PubMed

    Tubaishat, Ahmad; Tawalbeh, Loai I

    2015-09-01

    The realistic and practical environment that simulation provides is an extremely useful part of the teaching process. Simulation is widely used in health and nursing education today. This study aims to evaluate the effect of simulation-based teaching on the acquisition and retention of arrhythmia-related knowledge among nursing students. A randomized controlled design involving a pretest-posttest was used. Nursing students were allocated randomly either to the experimental group (n = 47), who attended simulation scenarios on cardiac arrhythmia, or to the control group (n = 44) who received a traditional lecture on the same topic. A paired t test showed that the mean knowledge score at the posttest was significantly higher than at the pretest for both groups. However, participants in the experimental group demonstrated significantly increased knowledge of cardiac arrhythmia in the first and the second posttest compared with those in the control group. Thus, simulation is superior and significantly improves students' arrhythmia knowledge. © The Author(s) 2014.

  3. Computer-assisted education system for arrhythmia (CAESAR).

    PubMed

    Fukushima, M; Inoue, M; Fukunami, M; Ishikawa, K; Inada, H; Abe, H

    1984-08-01

    A computer-assisted education system for arrhythmia (CAESAR) was developed for students to acquire the ability to logically diagnose complicated arrhythmias. This system has a logical simulator of cardiac rhythm using a mathematical model of the impulse formation and conduction system of the heart. A simulated arrhythmia (ECG pattern) is given on a graphic display unit with simulated series of the action potential of five pacemaker centers and the "ladder diagram" of impulse formation and conduction, which show the mechanism of that arrhythmia. For the purpose of the evaluation of this system, 13 medical students were given two types of tests concerning arrhythmias before and after 2-hr learning with this system. The scores they obtained after learning increased significantly from 73.3 +/- 11.9 to 93.2 +/- 3.0 (P less than 0.001) in one test and from 47.2 +/- 17.9 to 64.9 +/- 19.6 (P less than 0.001) in another one. These results proved that this CAI system is useful and effective for training ECG interpretation of arrhythmias.

  4. Privacy-Preserving Electrocardiogram Monitoring for Intelligent Arrhythmia Detection.

    PubMed

    Son, Junggab; Park, Juyoung; Oh, Heekuck; Bhuiyan, Md Zakirul Alam; Hur, Junbeom; Kang, Kyungtae

    2017-06-12

    Long-term electrocardiogram (ECG) monitoring, as a representative application of cyber-physical systems, facilitates the early detection of arrhythmia. A considerable number of previous studies has explored monitoring techniques and the automated analysis of sensing data. However, ensuring patient privacy or confidentiality has not been a primary concern in ECG monitoring. First, we propose an intelligent heart monitoring system, which involves a patient-worn ECG sensor (e.g., a smartphone) and a remote monitoring station, as well as a decision support server that interconnects these components. The decision support server analyzes the heart activity, using the Pan-Tompkins algorithm to detect heartbeats and a decision tree to classify them. Our system protects sensing data and user privacy, which is an essential attribute of dependability, by adopting signal scrambling and anonymous identity schemes. We also employ a public key cryptosystem to enable secure communication between the entities. Simulations using data from the MIT-BIH arrhythmia database demonstrate that our system achieves a 95.74% success rate in heartbeat detection and almost a 96.63% accuracy in heartbeat classification, while successfully preserving privacy and securing communications among the involved entities.

  5. Privacy-Preserving Electrocardiogram Monitoring for Intelligent Arrhythmia Detection †

    PubMed Central

    Son, Junggab; Park, Juyoung; Oh, Heekuck; Bhuiyan, Md Zakirul Alam; Hur, Junbeom; Kang, Kyungtae

    2017-01-01

    Long-term electrocardiogram (ECG) monitoring, as a representative application of cyber-physical systems, facilitates the early detection of arrhythmia. A considerable number of previous studies has explored monitoring techniques and the automated analysis of sensing data. However, ensuring patient privacy or confidentiality has not been a primary concern in ECG monitoring. First, we propose an intelligent heart monitoring system, which involves a patient-worn ECG sensor (e.g., a smartphone) and a remote monitoring station, as well as a decision support server that interconnects these components. The decision support server analyzes the heart activity, using the Pan–Tompkins algorithm to detect heartbeats and a decision tree to classify them. Our system protects sensing data and user privacy, which is an essential attribute of dependability, by adopting signal scrambling and anonymous identity schemes. We also employ a public key cryptosystem to enable secure communication between the entities. Simulations using data from the MIT-BIH arrhythmia database demonstrate that our system achieves a 95.74% success rate in heartbeat detection and almost a 96.63% accuracy in heartbeat classification, while successfully preserving privacy and securing communications among the involved entities. PMID:28604628

  6. Simulation of Atrial Fibrosis Using Coupled Myocyte-Fibroblast Cellular and Human Atrial Models

    PubMed Central

    Gao, Yuan

    2017-01-01

    Atrial fibrosis is characterized by expansion of extracellular matrix and increase in the number of fibroblasts which has been associated with the development and maintenance of atrial arrhythmias. However, the mechanisms how the fibrosis contributes to atrial arrhythmia remain incompletely understood. In this study, we used a proposed fibroblast model coupled with the human atrial myocyte to investigate the effects of fibrosis on atrial excitability and repolarization at both cellular and macroscopic levels. The 12-lead electrocardiogram (ECG) was also simulated to explore the index of clinical diagnosis for fibrosis. The simulation results showed that the fibrosis can modify action potential morphology of human atrial myocyte, slow down wave propagation, and have rate adaptation, thus causing the atrial electrical heterogeneity. The fibrosis alone was sufficient to cause arrhythmia, induce reentry wave, and result in low amplitude and wide P waves at normal heart rate and significant prolonged and inverse P waves at high heart rate. All these symptoms aggravated when the level of fibrosis increased. Our simulations demonstrated that fibrosis is the substrate of atrial arrhythmia and thereby may be a potential target in the treatment of atrial arrhythmias. PMID:29441121

  7. Intracardiac echo-facilitated 3D electroanatomical mapping of ventricular arrhythmias from the papillary muscles: assessing the 'fourth dimension' during ablation.

    PubMed

    Proietti, Riccardo; Rivera, Santiago; Dussault, Charles; Essebag, Vidal; Bernier, Martin L; Ayala-Paredes, Felix; Badra-Verdu, Mariano; Roux, Jean-François

    2017-01-01

    Ventricular arrhythmias (VA) originating from a papillary muscle (PM) have recently been described as a distinct clinical entity with peculiar features that make its treatment with catheter ablation challenging. Here, we report our experience using an intracardiac echo-facilitated 3D electroanatomical mapping approach in a case series of patients undergoing ablation for PM VA. Sixteen patients who underwent catheter ablation for ventricular tachycardia (VT) or symptomatic premature ventricular contractions originating from left ventricular PMs were included in the study. A total of 24 procedures (mean 1.5 per patient) were performed: 15 using a retrograde aortic approach and 9 using a transseptal approach. Integrated intracardiac ultrasound for 3D electroanatomical mapping was used in 15 of the 24 procedures. The posteromedial PM was the most frequent culprit for the clinical arrhythmia, and the body was the part of the PM most likely to be the successful site for ablation. The site of ablation was identified based on the best pace map matching the clinical arrhythmia and the site of earliest the activation. At a mean follow-up of 10.5 ± 7 months, only two patients had recurrent arrhythmias following a repeat ablation procedure. An echo-facilitated 3D electroanatomical mapping allows for real-time creation of precise geometries of cardiac chambers and endocavitary structures. This is useful during procedures such as catheter ablation of VAs originating from PMs, which require detailed representation of anatomical landmarks. Routine adoption of this technique should be considered to improve outcomes of PM VA ablation. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  8. The effect of Cardiac Arrhythmias Simulation Software on the nurses' learning and professional development.

    PubMed

    Bazrafkan, Leila; Hemmati, Mehdi

    2018-04-01

    One of the important tasks of nurses in intensive care unit is interpretation of ECG. The use of training simulator is a new paradigm in the age of computers. This study was performed to evaluate the impact of cardiac arrhythmias simulator software on nurses' learning in the subspecialty Vali-Asr Hospital in 2016. This study was conducted by quasi-experimental randomized Salomon four group design with the participation of 120 nurses in subspecialty Vali-Asr Hospital in Tehran, Iran in 2016 that were selected purposefully and allocated in 4 groups. By this design other confounding factors such as the prior information, maturation and the role of sex and age were controlled by Solomon 4 design. The valid and reliable multiple choice test tools were used to gather information; the validity of the test was approved by experts and its reliability was obtained by Cronbach's alpha coefficient 0.89. At first, the knowledge and skills of the participants were assessed by a pre-test; following the educational intervention with cardiac arrhythmias simulator software during 14 days in ICUs, the mentioned factors were measured for the two groups again by a post-test in the four groups. Data were analyzed using the two way ANOVA. The significance level was considered as p<0.05. Based on randomized four-group Solomon designs and our test results, using cardiac arrhythmias simulator software as an intervention was effective in the nurses' learning since a significant difference was found between pre-test and post-test in the first group (p<0.05). Also, other comparisons by ANOVA test showed that there was no interaction between pre-test and intervention in all of the three knowledge areas of cardiac arrhythmias, their treatments and their diagnosis (P>0.05). The use of software-based simulator for cardiac arrhythmias was effective in nurses' learning in light of its attractive components and interactive method. This intervention increased the knowledge of the nurses in cognitive domain of cardiac arrhythmias in addition to their diagnosis and treatment. Also, the package can be used for training in other areas such as continuing medical education.

  9. Simulation system of arrhythmia using ActiveX control.

    PubMed

    Takeuchi, Akihiro; Hirose, Minoru; Hamada, Atsushi; Ikeda, Noriaki

    2005-07-01

    A simulation system for arrhythmias has been developed using Windows-based software technology, ActiveX control. The cardiac module consists of six cells, the sinus, atrium, AV node, ventricle, and ectopic foci. The physiological properties of the cells, the automaticity and conduction delay, were modelled, respectively, by the phase response curve and the excitability recovery curve. Cell functions were implemented in the ActiveX control and incorporated into the cardiac module. The system draws the ECG sequence as a ladder diagram in real time. The system interactively shows diverse arrhythmias for various user settings of the cell function and bidirectional conduction between the cells. Users are able to experiment virtually by setting up a so-called electrophysiological stimulation. This system is useful for learning and for teaching the interaction between the cells and arrhythmias.

  10. Perspective: A Dynamics-Based Classification of Ventricular Arrhythmias

    PubMed Central

    Weiss, James N.; Garfinkel, Alan; Karagueuzian, Hrayr S.; Nguyen, Thao P.; Olcese, Riccardo; Chen, Peng-Sheng; Qu, Zhilin

    2015-01-01

    Despite key advances in the clinical management of life-threatening ventricular arrhythmias, culminating with the development of implantable cardioverter-defibrillators and catheter ablation techniques, pharmacologic/biologic therapeutics have lagged behind. The fundamental issue is that biological targets are molecular factors. Diseases, however, represent emergent properties at the scale of the organism that result from dynamic interactions between multiple constantly changing molecular factors. For a pharmacologic/biologic therapy to be effective, it must target the dynamic processes that underlie the disease. Here we propose a classification of ventricular arrhythmias that is based on our current understanding of the dynamics occurring at the subcellular, cellular, tissue and organism scales, which cause arrhythmias by simultaneously generating arrhythmia triggers and exacerbating tissue vulnerability. The goal is to create a framework that systematically links these key dynamic factors together with fixed factors (structural and electrophysiological heterogeneity) synergistically promoting electrical dispersion and increased arrhythmia risk to molecular factors that can serve as biological targets. We classify ventricular arrhythmias into three primary dynamic categories related generally to unstable Ca cycling, reduced repolarization, and excess repolarization, respectively. The clinical syndromes, arrhythmia mechanisms, dynamic factors and what is known about their molecular counterparts are discussed. Based on this framework, we propose a computational-experimental strategy for exploring the links between molecular factors, fixed factors and dynamic factors that underlie life-threatening ventricular arrhythmias. The ultimate objective is to facilitate drug development by creating an in silico platform to evaluate and predict comprehensively how molecular interventions affect not only a single targeted arrhythmia, but all primary arrhythmia dynamics categories as well as normal cardiac excitation-contraction coupling. PMID:25769672

  11. Non-Invasive Assessment of Susceptibility to Ventricular Arrhythmias During Simulated Microgravity

    NASA Technical Reports Server (NTRS)

    Cohen, Richard J.

    1999-01-01

    The Cardiovascular Alterations Team is currently conducting studies to determine what alterations in hemodynamic regulation result from sixteen days of simulated microgravity exposure in normal human subjects. In this project we make additional measurements on these same study subjects in order to determine whether there is an increase in susceptibility to ventricular arrhythmias resulting from simulated microgravity exposure. Numerous anecdotal and documented reports from the past 30 years suggest that the incidence of ventricular arrhythmias among astronauts is increased during space flight. For example, documented runs of ventricular tachycardia have been recorded from crew members of Skylab and Mir, there was much attention given by the lay press to Mir Commander Vasily Tslbliyev's complaints of heart rhythm irregularities in July of 1997, and cardiovascular mechanisms may have been causal in the recent death of an experimental primate shortly after return from space. In 1986, a Mir cosmonaut, Alexander Laveikin, was brought home and replaced with an alternate cosmonaut as a result of cardiac dysrhythmias that began during extravehicular activity. Furthermore, at a joint NASA/NSBRI workshop held in January 1998, cardiac arrhythmias were identified as the highest priority cardiovascular risk to a human Mars mission. Despite the evidence for the risk of a potentially lethal arrhythmia resulting from microgravity exposure, the effects of space flight and the associated physiologic stresses on cardiac conduction processes are not known, and an increase in cardiac susceptibility to arrhythmias has never been quantified. In this project, we are determining whether simulated space flight increases the risk of developing life-threatening heart rhythm disturbances such as sustained ventricular tachycardia (defined as ventricular tachycardia lasting at least 30 seconds or resulting in hemodynamic collapse) and ventricular fibrillation. We are obtaining measures of cardiac susceptibility to ventricular arrhythmias in subjects exposed to simulated space flight in the Human Studies Core protocol being conducted by the Cardiovascular Alterations Team, which involves sixteen days .of bed rest. In particular, we are applying a powerful new non-invasive technology, developed in Professor Cohen's laboratory at MIT for the quantitative assessment of the risk of life-threatening ventricular arrhythmias. This technology involves the measurement of microvolt levels of T wave alternans (TWA) during exercise stress, and was recently granted approval by the Food and Drug Administration to be used for the clinical evaluation of patients suspected to be at risk of ventricular arrhythmias. In addition, we are obtaining 24 hour Holter monitoring (to detect non-sustained ventricular tachycardia and to assess heart rate variability). We are also conducting protocols to obtain these same measures on a monthly basis for up to four months in subjects in the Bone Demineralization/calcium Metaboloism Team's long term bed rest study.

  12. Simulation of Spiral Waves and Point Sources in Atrial Fibrillation with Application to Rotor Localization

    PubMed Central

    Ganesan, Prasanth; Shillieto, Kristina E.; Ghoraani, Behnaz

    2018-01-01

    Cardiac simulations play an important role in studies involving understanding and investigating the mechanisms of cardiac arrhythmias. Today, studies of arrhythmogenesis and maintenance are largely being performed by creating simulations of a particular arrhythmia with high accuracy comparable to the results of clinical experiments. Atrial fibrillation (AF), the most common arrhythmia in the United States and many other parts of the world, is one of the major field where simulation and modeling is largely used. AF simulations not only assist in understanding its mechanisms but also help to develop, evaluate and improve the computer algorithms used in electrophysiology (EP) systems for ablation therapies. In this paper, we begin with a brief overeview of some common techniques used in simulations to simulate two major AF mechanisms – spiral waves (or rotors) and point (or focal) sources. We particularly focus on 2D simulations using Nygren et al.’s mathematical model of human atrial cell. Then, we elucidate an application of the developed AF simulation to an algorithm designed for localizing AF rotors for improving current AF ablation therapies. Our simulation methods and results, along with the other discussions presented in this paper is aimed to provide engineers and professionals with a working-knowledge of application-specific simulations of spirals and foci. PMID:29629398

  13. European Heart Rhythm Association (EHRA) position paper on arrhythmia management and device therapies in endocrine disorders, endorsed by Asia Pacific Heart Rhythm Society (APHRS) and Latin American Heart Rhythm Society (LAHRS).

    PubMed

    Gorenek, Bulent; Boriani, Giuseppe; Dan, Gheorge-Andrei; Fauchier, Laurent; Fenelon, Guilherme; Huang, He; Kudaiberdieva, Gulmira; Lip, Gregory Y H; Mahajan, Rajiv; Potpara, Tatjana; Ramirez, Juan David; Vos, Marc A; Marin, Francisco

    2018-03-16

    Endocrine disorders are associated with various tachyarrhythmias, including atrial fibrillation (AF), ventricular tachycardia (VT), ventricular fibrillation (VF), and bradyarrhythmias. Along with underlying arrhythmia substrate, electrolyte disturbances, glucose, and hormone levels, accompanying endocrine disorders contribute to development of arrhythmia. Arrhythmias may be life-threatening, facilitate cardiogenic shock development and increase mortality. The knowledge on the incidence of tachy- and bradyarrhythmias, clinical and prognostic significance as well as their management is limited; it is represented in observational studies and mostly in case reports on management of challenging cases. It should be also emphasized, that the topic is not covered in detail in current guidelines. Therefore, cardiologists and multidisciplinary teams participating in care of such patients do need the evidence-based, or in case of limited evidence expert-opinion based recommendations, how to treat arrhythmias using contemporary approaches, prevent their complications and recurrence in patients with endocrine disorders. In recognizing this close relationship between endocrine disorders and arrhythmias, the European Heart Rhythm Association (EHRA) convened a Task Force, with representation from Asia-Pacific Heart Rhythm Society (APHRS) and Sociedad Latinoamericana de Estimulación Cardíaca y Electrofisiología (SOLAECE), with the remit of comprehensively reviewing the available evidence and publishing a joint consensus document on endocrine disorders and cardiac arrhythmias, and providing up-to-date consensus recommendations for use in clinical practice.

  14. The association of air temperature with cardiac arrhythmias

    NASA Astrophysics Data System (ADS)

    Čulić, Viktor

    2017-11-01

    The body response to meteorological influences may activate pathophysiological mechanisms facilitating the occurrence of cardiac arrhythmias in susceptible patients. Putative underlying mechanisms include changes in systemic vascular resistance and blood pressure, as well as a network of proinflammatory and procoagulant processes. Such a chain reaction probably occurs within the time window of several hours, so use of daily average values of meteorological elements do not seem appropriate for investigation in this area. In addition, overall synoptic situation, and season-specific combinations of meteorological elements and air pollutant levels probably cause the overall effect rather than a single atmospheric element. Particularly strong interrelations have been described among wind speed, air pressure and temperature, relative air humidity, and suspended particulate matter. This may be the main reason why studies examining the association between temperature and ventricular arrhythmias have found linear positive, negative, J-shaped or no association. Further understanding of the pathophysiological adaptation to atmospheric environment may help in providing recommendations for protective measures during "bad" weather conditions in patients with cardiac arrhythmias.

  15. Integrative computational models of cardiac arrhythmias -- simulating the structurally realistic heart

    PubMed Central

    Trayanova, Natalia A; Tice, Brock M

    2009-01-01

    Simulation of cardiac electrical function, and specifically, simulation aimed at understanding the mechanisms of cardiac rhythm disorders, represents an example of a successful integrative multiscale modeling approach, uncovering emergent behavior at the successive scales in the hierarchy of structural complexity. The goal of this article is to present a review of the integrative multiscale models of realistic ventricular structure used in the quest to understand and treat ventricular arrhythmias. It concludes with the new advances in image-based modeling of the heart and the promise it holds for the development of individualized models of ventricular function in health and disease. PMID:20628585

  16. Alcohol, cardiac arrhythmias and sudden death.

    PubMed

    Kupari, M; Koskinen, P

    1998-01-01

    Studies in experimental animals have shown varying and apparently opposite effects of alcohol on cardiac rhythm and conduction. Given acutely to non-alcoholic animals, ethanol may even have anti-arrhythmic properties whereas chronic administration clearly increases the animals' susceptibility to cardiac arrhythmias. Chronic heavy alcohol use has been incriminated in the genesis of cardiac arrhythmias in humans. The evidence has come from clinical observations, retrospective case-control studies, controlled studies of consecutive admissions for arrhythmias, and prospective epidemiological investigations. Furthermore, electrophysiological studies have shown that acute alcohol administration facilitates the induction of tachyarrhythmias in selected heavy drinkers. The role of alcohol appears particularly conspicuous in idiopathic atrial fibrillation. Occasionally, ventricular tachyarrhythmias have also been provoked by alcohol intake. Several lines of evidence suggest that heavy drinking increases the risk of sudden cardiac death with fatal arrhythmia as the most likely mechanism. According to epidemiological studies this effect appears most prominent in middle-aged men and is only partly explained by confounding traits such as smoking and social class. The basic arrhythmogenic effects of alcohol are still insufficiently delineated. Subclinical heart muscle injury from chronic heavy use may be instrumental in producing patchy delays in conduction. The hyperadrenergic state of drinking and withdrawal may also contribute, as may electrolyte abnormalities, impaired vagal heart rate control, repolarization abnormalities with prolonged QT intervals and worsening of myocardial ischaemia or sleep apnoea. Most of what we know about alcohol and arrhythmias relates to heavy drinking. The effect of social drinking on clinical arrhythmias in non-alcoholic cardiac patients needs to be addressed further.

  17. Use of New Imaging CARTO® Segmentation Module Software to Facilitate Ablation of Ventricular Arrhythmias.

    PubMed

    Tovia-Brodie, Oholi; Belhassen, Bernard; Glick, Aharon; Shmilovich, Haim; Aviram, Galit; Rosso, Raphael; Michowitz, Yoav

    2017-02-01

    A new imaging software (CARTO® Segmentation Module, Biosense Webster) allows preprocedural 3-D reconstruction of all heart chambers based on cardiac CT. We describe our initial experience with the new module during ablation of ventricular arrhythmias. Eighteen consecutive patients with idiopathic ventricular arrhythmias or ischemic ventricular tachycardia (VT) were studied. In the latter group, a combined endocardial and epicardial ablation was performed. Of the 14 patients with idiopathic arrhythmias, 12 were ablated in the outflow tract (OT), 1 in the midseptal left ventricle, and 1 at the left posterior fascicular area; acute successful ablation was achieved in 11 (78.6%) patients. The procedure was discontinued due to close proximity of the arrhythmia origin to the coronary arteries (CA) in 2 patients. Acute successful uncomplicated ablation was achieved in all 4 patients with ischemic VT. During ablation in the coronary cusps commissures, the CARTO® Segmentation Module accurately defined the cusps anatomy. The precise anatomic location provided by the module assisted in successfully ablating when information from activation mapping was not optimal, by ablating at the opposite side of the cusps. In addition, by demonstrating the precise location of the CA, it allowed safe ablation of arrhythmias that originated in close proximity to the CA both in the OT area and the epicardium, eliminating the need for repeat angiography. The CARTO® Segmentation Module is useful for accurate definition of the exact anatomic location of ventricular arrhythmias and for safely ablating them especially in close proximity to the CA. © 2016 Wiley Periodicals, Inc.

  18. Electrical stimulation-based renal nerve mapping exacerbates ventricular arrhythmias during acute myocardial ischaemia.

    PubMed

    Huang, Bing; Zhou, Xiaoya; Wang, Menglong; Li, Xuefei; Zhou, Liping; Meng, Guannan; Wang, Yuhong; Wang, Zhuo; Wang, Songyun; Yu, Lilei; Jiang, Hong

    2018-06-01

    Blood pressure elevation in response to transient renal nerve stimulation (RNS) has been used to determine the ablation target and endpoint of renal denervation. This study aimed to evaluate the safety of transient RNS in canines with normal or ischaemic hearts. In ten normal (Group 1) and six healed myocardial infarction (HMI) (Group 2) canines, a large-tip catheter was inserted into the left or right renal artery to perform transient RNS. The left stellate ganglion neural activity (LSGNA) and ventricular electrophysiological parameters were measured at baseline and during transient RNS. In another 20 acute myocardial infarction (AMI) canines, RNS (Group 3, n = 10) or sham RNS (Group 4, n = 10) was intermittently (1 min ON and 4 min OFF) performed for 1 h following AMI induction. The LSGNA and AMI-induced ventricular arrhythmias were analysed. In normal and HMI canines, although transient RNS significantly increased the LSGNA and facilitated the action potential duration (APD) alternans, it did not induce any ventricular arrhythmias and did not change the ventricular effective refractory period, APD or maximum slope of the APD restitution curve. In AMI canines, transient RNS significantly exacerbated LSG activation and promoted the incidence of ventricular arrhythmias. Transient RNS did not increase the risk of ventricular arrhythmias in normal or HMI hearts, but it significantly promoted the occurrence of ventricular arrhythmias in AMI hearts. Therefore, electrical stimulation-based renal nerve mapping may be unsafe in AMI patients and in patients with a high risk for malignant ventricular arrhythmias.

  19. Simulation of Cardiac Arrhythmias Using a 2D Heterogeneous Whole Heart Model

    PubMed Central

    Balakrishnan, Minimol; Chakravarthy, V. Srinivasa; Guhathakurta, Soma

    2015-01-01

    Simulation studies of cardiac arrhythmias at the whole heart level with electrocardiogram (ECG) gives an understanding of how the underlying cell and tissue level changes manifest as rhythm disturbances in the ECG. We present a 2D whole heart model (WHM2D) which can accommodate variations at the cellular level and can generate the ECG waveform. It is shown that, by varying cellular-level parameters like the gap junction conductance (GJC), excitability, action potential duration (APD) and frequency of oscillations of the auto-rhythmic cell in WHM2D a large variety of cardiac arrhythmias can be generated including sinus tachycardia, sinus bradycardia, sinus arrhythmia, sinus pause, junctional rhythm, Wolf Parkinson White syndrome and all types of AV conduction blocks. WHM2D includes key components of the electrical conduction system of the heart like the SA (Sino atrial) node cells, fast conducting intranodal pathways, slow conducting atriovenctricular (AV) node, bundle of His cells, Purkinje network, atrial, and ventricular myocardial cells. SA nodal cells, AV nodal cells, bundle of His cells, and Purkinje cells are represented by the Fitzhugh-Nagumo (FN) model which is a reduced model of the Hodgkin-Huxley neuron model. The atrial and ventricular myocardial cells are modeled by the Aliev-Panfilov (AP) two-variable model proposed for cardiac excitation. WHM2D can prove to be a valuable clinical tool for understanding cardiac arrhythmias. PMID:26733873

  20. Mathematical Approaches to Understanding and Imaging Atrial Fibrillation: Significance for Mechanisms and Management

    PubMed Central

    Trayanova, Natalia A

    2014-01-01

    Atrial fibrillation (AF) is the most common sustained arrhythmia in humans. The mechanisms that govern AF initiation and persistence are highly complex, of dynamic nature, and involve interactions across multiple temporal and spatial scales in the atria. This articles aims to review the mathematical modeling and computer simulation approaches to understanding AF mechanisms and aiding in its management. Various atrial modeling approaches are presented, with descriptions of the methodological basis and advancements in both lower-dimensional and realistic geometry models. A review of the most significant mechanistic insights made by atrial simulations is provided. The article showcases the contributions that atrial modeling and simulation have made not only to our understanding of the pathophysiology of atrial arrhythmias, but also to the development of AF management approaches. A summary of the future developments envisioned for the field of atrial simulation and modeling is also presented. The review contends that computational models of the atria assembled with data from clinical imaging modalities that incorporate electrophysiological and structural remodeling could become a first line of screening for new AF therapies and approaches, new diagnostic developments, and new methods for arrhythmia prevention. PMID:24763468

  1. Effect of myocyte-fibroblast coupling on the onset of pathological dynamics in a model of ventricular tissue

    NASA Astrophysics Data System (ADS)

    Sridhar, S.; Vandersickel, Nele; Panfilov, Alexander V.

    2017-01-01

    Managing lethal cardiac arrhythmias is one of the biggest challenges in modern cardiology, and hence it is very important to understand the factors underlying such arrhythmias. While early afterdepolarizations (EAD) of cardiac cells is known to be one such arrhythmogenic factor, the mechanisms underlying the emergence of tissue level arrhythmias from cellular level EADs is not fully understood. Another known arrhythmogenic condition is fibrosis of cardiac tissue that occurs both due to aging and in many types of heart diseases. In this paper we describe the results of a systematic in-silico study, using the TNNP model of human cardiac cells and MacCannell model for (myo)fibroblasts, on the possible effects of diffuse fibrosis on arrhythmias occurring via EADs. We find that depending on the resting potential of fibroblasts (VFR), M-F coupling can either increase or decrease the region of parameters showing EADs. Fibrosis increases the probability of occurrence of arrhythmias after a single focal stimulation and this effect increases with the strength of the M-F coupling. While in our simulations, arrhythmias occur due to fibrosis induced ectopic activity, we do not observe any specific fibrotic pattern that promotes the occurrence of these ectopic sources.

  2. Arctigenin, a potential anti-arrhythmic agent, inhibits aconitine-induced arrhythmia by regulating multi-ion channels.

    PubMed

    Zhao, Zhenying; Yin, Yongqiang; Wu, Hong; Jiang, Min; Lou, Jianshi; Bai, Gang; Luo, Guo'an

    2013-01-01

    Arctigenin possesses biological activities, but its underlying mechanisms at the cellular and ion channel levels are not completely understood. Therefore, the present study was designed to identify the anti-arrhythmia effect of arctigenin in vivo, as well as its cellular targets and mechanisms. A rat arrhythmia model was established via continuous aconitine infusion, and the onset times of ventricular premature contraction, ventricular tachycardia and death were recorded. The Action Potential Duration (APD), sodium current (I(Na)), L-type calcium current (I(Ca, L)) and transient outward potassium current (I(to)) were measured and analysed using a patch-clamp recording technique in normal rat cardiomyocytes and myocytes of arrhythmia aconitine-induced by. Arctigenin significantly delayed the arrhythmia onset in the aconitine-induced rat model. The 50% and 90% repolarisations (APD50 and APD90) were shortened by 100 µM arctigenin; the arctigenin dose also inhibited the prolongation of APD50 and APD90 caused by 1 µM aconitine. Arctigenin inhibited I(Na) and I(Ca,L) and attenuated the aconitine-increased I(Na) and I(Ca,L) by accelerating the activation process and delaying the inactivation process. Arctigenin enhanced Ito by facilitating the activation process and delaying the inactivation process, and recoverd the decreased Ito induced by aconitine. Arctigenin has displayed anti-arrhythmia effects, both in vivo and in vitro. In the context of electrophysiology, I(Na), I(Ca, L), and I(to) may be multiple targets of arctigenin, leading to its antiarrhythmic effect. © 2013 S. Karger AG, Basel.

  3. A real time ECG signal processing application for arrhythmia detection on portable devices

    NASA Astrophysics Data System (ADS)

    Georganis, A.; Doulgeraki, N.; Asvestas, P.

    2017-11-01

    Arrhythmia describes the disorders of normal heart rate, which, depending on the case, can even be fatal for a patient with severe history of heart disease. The purpose of this work is to develop an application for heart signal visualization, processing and analysis in Android portable devices e.g. Mobile phones, tablets, etc. The application is able to retrieve the signal initially from a file and at a later stage this signal is processed and analysed within the device so that it can be classified according to the features of the arrhythmia. In the processing and analysing stage, different algorithms are included among them the Moving Average and Pan Tompkins algorithm as well as the use of wavelets, in order to extract features and characteristics. At the final stage, testing is performed by simulating our application in real-time records, using the TCP network protocol for communicating the mobile with a simulated signal source. The classification of ECG beat to be processed is performed by neural networks.

  4. Cardiac arrhythmias during aerobatic flight and its simulation on a centrifuge.

    PubMed

    Zawadzka-Bartczak, Ewelina K; Kopka, Lech H

    2011-06-01

    It is well known that accelerations during centrifuge training and during flight can provoke cardiac arrhythmias. Our study was designed to investigate both the similarities and differences between heart rhythm disturbances during flights and centrifuge tests. There were 40 asymptomatic, healthy pilots who performed two training flights and were also tested in a human centrifuge according to a program of rapid onset rate acceleration (ROR) and of centrifuge simulation of the actual acceleration experienced in flight (Simulation). During the flight and centrifuge tests ECG was monitored with the Holter method. ECG was examined for heart rhythm changes and disturbances. During flights, premature ventricular contractions (PVCs) were found in 25% of the subjects, premature supraventricular contractions (PSVCs) and PVCs with bigeminy in 5%, and pairs of PVCs in 2.5% of subjects. During the centrifuge tests, PVCs were experienced by 45% of the subjects, PSVCs and pairs of PVCs by 7.5%, and PVCs with bigeminy by 2.5%. Sinus bradycardia was observed during flights and centrifuge tests in 7.5% of subjects. Comparative evaluation of electrocardiographic records in military pilots during flights and centrifuge tests demonstrated that: 1) there were no clinically significant arrhythmias recorded; and 2) the frequency and kind of heart rhythm disturbances during aerobatic flight and its simulation on a centrifuge were not identical and did not occur repetitively in the same persons during equal phases of the tests.

  5. Functional and clinical characterization of KCNJ2 mutations associated with LQT7 (Andersen syndrome)

    PubMed Central

    Tristani-Firouzi, Martin; Jensen, Judy L.; Donaldson, Matthew R.; Sansone, Valeria; Meola, Giovanni; Hahn, Angelika; Bendahhou, Said; Kwiecinski, Hubert; Fidzianska, Anna; Plaster, Nikki; Fu, Ying-Hui; Ptacek, Louis J.; Tawil, Rabi

    2002-01-01

    Andersen syndrome (AS) is a rare, inherited disorder characterized by periodic paralysis, long QT (LQT) with ventricular arrhythmias, and skeletal developmental abnormalities. We recently established that AS is caused by mutations in KCNJ2, which encodes the inward rectifier K+ channel Kir2.1. In this report, we characterized the functional consequences of three novel and seven previously described KCNJ2 mutations using a two-microelectrode voltage-clamp technique and correlated the findings with the clinical phenotype. All mutations resulted in loss of function and dominant-negative suppression of Kir2.1 channel function. In mutation carriers, the frequency of periodic paralysis was 64% and dysmorphic features 78%. LQT was the primary cardiac manifestation, present in 71% of KCNJ2 mutation carriers, with ventricular arrhythmias present in 64%. While arrhythmias were common, none of our subjects suffered sudden cardiac death. To gain insight into the mechanism of arrhythmia susceptibility, we simulated the effect of reduced Kir2.1 using a ventricular myocyte model. A reduction in Kir2.1 prolonged the terminal phase of the cardiac action potential, and in the setting of reduced extracellular K+, induced Na+/Ca2+ exchanger–dependent delayed afterdepolarizations and spontaneous arrhythmias. These findings suggest that the substrate for arrhythmia susceptibility in AS is distinct from the other forms of inherited LQT syndrome. PMID:12163457

  6. Smartphone ECG aids real time diagnosis of palpitations in the competitive college athlete.

    PubMed

    Peritz, David C; Howard, Austin; Ciocca, Mario; Chung, Eugene H

    2015-01-01

    Rapidly detecting dangerous arrhythmias in a symptomatic athlete continues to be an elusive goal. The use of handheld smartphone electrocardiogram (ECG) monitors could represent a helpful tool connecting the athletic trainer to the cardiologist. Six college athletes presented to their athletic trainers complaining of palpitations during exercise. A single lead ECG was performed using the AliveCor Heart Monitor and sent wirelessly to the Team Cardiologist who confirmed an absence of dangerous arrhythmia. AliveCor monitoring has the potential to enhance evaluation of symptomatic athletes by allowing trainers and team physicians to make diagnosis in real-time and facilitate faster return to play. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. Early assessment of proarrhythmic risk of drugs using the in vitro data and single-cell-based in silico models: proof of concept.

    PubMed

    Abbasi, Mitra; Small, Ben G; Patel, Nikunjkumar; Jamei, Masoud; Polak, Sebastian

    2017-02-01

    To determine the predictive performance of in silico models using drug-specific preclinical cardiac electrophysiology data to investigate drug-induced arrhythmia risk (e.g. Torsade de pointes (TdP)) in virtual human subjects. To assess drug proarrhythmic risk, we used a set of in vitro electrophysiological measurements describing ion channel inhibition triggered by the investigated drugs. The Cardiac Safety Simulator version 2.0 (CSS; Simcyp, Sheffield, UK) platform was used to simulate human left ventricular cardiac myocyte action potential models. This study shows the impact of drug concentration changes on particular ionic currents by using available experimental data. The simulation results display safety threshold according to drug concentration threshold and log (threshold concentration/ effective therapeutic plasma concentration (ETPC)). We reproduced the underlying biophysical characteristics of cardiac cells resulted in effects of drugs associated with cardiac arrhythmias (action potential duration (APD) and QT prolongation and TdP) which were observed in published 3D simulations, yet with much less computational burden.

  8. Cardiac arrhythmia mechanisms in rats with heart failure induced by pulmonary hypertension

    PubMed Central

    Benoist, David; Stones, Rachel; Drinkhill, Mark J.; Benson, Alan P.; Yang, Zhaokang; Cassan, Cecile; Gilbert, Stephen H.; Saint, David A.; Cazorla, Olivier; Steele, Derek S.; Bernus, Olivier

    2012-01-01

    Pulmonary hypertension provokes right heart failure and arrhythmias. Better understanding of the mechanisms underlying these arrhythmias is needed to facilitate new therapeutic approaches for the hypertensive, failing right ventricle (RV). The aim of our study was to identify the mechanisms generating arrhythmias in a model of RV failure induced by pulmonary hypertension. Rats were injected with monocrotaline to induce either RV hypertrophy or failure or with saline (control). ECGs were measured in conscious, unrestrained animals by telemetry. In isolated hearts, electrical activity was measured by optical mapping and myofiber orientation by diffusion tensor-MRI. Sarcoplasmic reticular Ca2+ handling was studied in single myocytes. Compared with control animals, the T-wave of the ECG was prolonged and in three of seven heart failure animals, prominent T-wave alternans occurred. Discordant action potential (AP) alternans occurred in isolated failing hearts and Ca2+ transient alternans in failing myocytes. In failing hearts, AP duration and dispersion were increased; conduction velocity and AP restitution were steeper. The latter was intrinsic to failing single myocytes. Failing hearts had greater fiber angle disarray; this correlated with AP duration. Failing myocytes had reduced sarco(endo)plasmic reticular Ca2+-ATPase activity, increased sarcoplasmic reticular Ca2+-release fraction, and increased Ca2+ spark leak. In hypertrophied hearts and myocytes, dysfunctional adaptation had begun, but alternans did not develop. We conclude that increased electrical and structural heterogeneity and dysfunctional sarcoplasmic reticular Ca2+ handling increased the probability of alternans, a proarrhythmic predictor of sudden cardiac death. These mechanisms are potential therapeutic targets for the correction of arrhythmias in hypertensive, failing RVs. PMID:22427523

  9. Bile acids induce arrhythmias in human atrial myocardium--implications for altered serum bile acid composition in patients with atrial fibrillation.

    PubMed

    Rainer, Peter P; Primessnig, Uwe; Harenkamp, Sandra; Doleschal, Bernhard; Wallner, Markus; Fauler, Guenter; Stojakovic, Tatjana; Wachter, Rolf; Yates, Ameli; Groschner, Klaus; Trauner, Michael; Pieske, Burkert M; von Lewinski, Dirk

    2013-11-01

    High bile acid serum concentrations have been implicated in cardiac disease, particularly in arrhythmias. Most data originate from in vitro studies and animal models. We tested the hypotheses that (1) high bile acid concentrations are arrhythmogenic in adult human myocardium, (2) serum bile acid concentrations and composition are altered in patients with atrial fibrillation (AF) and (3) the therapeutically used ursodeoxycholic acid has different effects than other potentially toxic bile acids. Multicellular human atrial preparations ('trabeculae') were exposed to primary bile acids and the incidence of arrhythmic events was assessed. Bile acid concentrations were measured in serum samples from 250 patients and their association with AF and ECG parameters analysed. Additionally, we conducted electrophysiological studies in murine myocytes. Taurocholic acid (TCA) concentration-dependently induced arrhythmias in atrial trabeculae (14/28 at 300 µM TCA, p<0.01) while ursodeoxycholic acid did not. Patients with AF had significantly decreased serum levels of ursodeoxycholic acid conjugates and increased levels of non-ursodeoxycholic bile acids. In isolated myocytes, TCA depolarised the resting membrane potential, enhanced Na(+)/Ca(2+) exchanger (NCX) tail current density and induced afterdepolarisations. Inhibition of NCX prevented arrhythmias in atrial trabeculae. High TCA concentrations induce arrhythmias in adult human atria while ursodeoxycholic acid does not. AF is associated with higher serum levels of non-ursodeoxycholic bile acid conjugates and low levels of ursodeoxycholic acid conjugates. These data suggest that higher levels of toxic (arrhythmogenic) and low levels of protective bile acids create a milieu with a decreased arrhythmic threshold and thus may facilitate arrhythmic events.

  10. Current Interventional and Surgical Management of Congenital Heart Disease: Specific Focus on Valvular Disease and Cardiac Arrhythmias.

    PubMed

    Holst, Kimberly A; Said, Sameh M; Nelson, Timothy J; Cannon, Bryan C; Dearani, Joseph A

    2017-03-17

    Successful outcome in the care of patients with congenital heart disease depends on a comprehensive multidisciplinary team. Surgery is offered for almost every heart defect, despite complexity. Early mortality for cardiac surgery in the neonatal period is ≈10% and beyond infancy is <5%, with 90% to 95% of patients surviving with a good quality of life into the adult years. Advances in imaging have facilitated accurate diagnosis and planning of interventions and surgical procedures. Similarly, advances in the perioperative medical management of patients, particularly with intensive care, has also contributed to improving outcomes. Arrhythmias and heart failure are the most common late complications for the majority of defects, and reoperation for valvar problems is common. Lifelong surveillance for monitoring of recurrent or residual structural heart defects, as well as periodic assessment of cardiac function and arrhythmia monitoring, is essential for all patients. The field of congenital heart surgery is poised to incorporate new innovations such as bioengineered cells and scaffolds that will iteratively move toward bioengineered patches, conduits, valves, and even whole organs. © 2017 American Heart Association, Inc.

  11. Differential roles of two delayed rectifier potassium currents in regulation of ventricular action potential duration and arrhythmia susceptibility.

    PubMed

    Devenyi, Ryan A; Ortega, Francis A; Groenendaal, Willemijn; Krogh-Madsen, Trine; Christini, David J; Sobie, Eric A

    2017-04-01

    Arrhythmias result from disruptions to cardiac electrical activity, although the factors that control cellular action potentials are incompletely understood. We combined mathematical modelling with experiments in heart cells from guinea pigs to determine how cellular electrical activity is regulated. A mismatch between modelling predictions and the experimental results allowed us to construct an improved, more predictive mathematical model. The balance between two particular potassium currents dictates how heart cells respond to perturbations and their susceptibility to arrhythmias. Imbalances of ionic currents can destabilize the cardiac action potential and potentially trigger lethal cardiac arrhythmias. In the present study, we combined mathematical modelling with information-rich dynamic clamp experiments to determine the regulation of action potential morphology in guinea pig ventricular myocytes. Parameter sensitivity analysis was used to predict how changes in ionic currents alter action potential duration, and these were tested experimentally using dynamic clamp, a technique that allows for multiple perturbations to be tested in each cell. Surprisingly, we found that a leading mathematical model, developed with traditional approaches, systematically underestimated experimental responses to dynamic clamp perturbations. We then re-parameterized the model using a genetic algorithm, which allowed us to estimate ionic current levels in each of the cells studied. This unbiased model adjustment consistently predicted an increase in the rapid delayed rectifier K + current and a drastic decrease in the slow delayed rectifier K + current, and this prediction was validated experimentally. Subsequent simulations with the adjusted model generated the clinically relevant prediction that the slow delayed rectifier is better able to stabilize the action potential and suppress pro-arrhythmic events than the rapid delayed rectifier. In summary, iterative coupling of simulations and experiments enabled novel insight into how the balance between cardiac K + currents influences ventricular arrhythmia susceptibility. © 2016 The Authors. The Journal of Physiology © 2016 The Physiological Society.

  12. Getting to the heart of hERG K(+) channel gating.

    PubMed

    Perry, Matthew D; Ng, Chai-Ann; Mann, Stefan A; Sadrieh, Arash; Imtiaz, Mohammad; Hill, Adam P; Vandenberg, Jamie I

    2015-06-15

    Potassium ion channels encoded by the human ether-a-go-go related gene (hERG) form the ion-conducting subunit of the rapid delayed rectifier potassium current (IKr ). Although hERG channels exhibit a widespread tissue distribution they play a particularly important role in the heart. There has been considerable interest in hERG K(+) channels for three main reasons. First, they have very unusual gating kinetics, most notably rapid and voltage-dependent inactivation coupled to slow deactivation, which has led to the suggestion that they may play a specific role in the suppression of arrhythmias. Second, mutations in hERG are the cause of 30-40% of cases of congenital long QT syndrome (LQTS), the commonest inherited primary arrhythmia syndrome. Third, hERG is the molecular target for the vast majority of drugs that cause drug-induced LQTS, the commonest cause of drug-induced arrhythmias and cardiac death. Drug-induced LQTS has now been reported for a large range of both cardiac and non-cardiac drugs, in which this side effect is entirely undesired. In recent years there have been comprehensive reviews published on hERG K(+) channels (Vandenberg et al. 2012) and we will not re-cover this ground. Rather, we focus on more recent work on the structural basis and dynamics of hERG gating with an emphasis on how the latest developments may facilitate translational research in the area of stratifying risk of arrhythmias. © 2015 The Authors. The Journal of Physiology © 2015 The Physiological Society.

  13. Getting to the heart of hERG K+ channel gating

    PubMed Central

    Perry, Matthew D; Ng, Chai-Ann; Mann, Stefan A; Sadrieh, Arash; Imtiaz, Mohammad; Hill, Adam P; Vandenberg, Jamie I

    2015-01-01

    Potassium ion channels encoded by the human ether-a-go-go related gene (hERG) form the ion-conducting subunit of the rapid delayed rectifier potassium current (IKr). Although hERG channels exhibit a widespread tissue distribution they play a particularly important role in the heart. There has been considerable interest in hERG K+ channels for three main reasons. First, they have very unusual gating kinetics, most notably rapid and voltage-dependent inactivation coupled to slow deactivation, which has led to the suggestion that they may play a specific role in the suppression of arrhythmias. Second, mutations in hERG are the cause of 30–40% of cases of congenital long QT syndrome (LQTS), the commonest inherited primary arrhythmia syndrome. Third, hERG is the molecular target for the vast majority of drugs that cause drug-induced LQTS, the commonest cause of drug-induced arrhythmias and cardiac death. Drug-induced LQTS has now been reported for a large range of both cardiac and non-cardiac drugs, in which this side effect is entirely undesired. In recent years there have been comprehensive reviews published on hERG K+ channels (Vandenberg et al. 2012) and we will not re-cover this ground. Rather, we focus on more recent work on the structural basis and dynamics of hERG gating with an emphasis on how the latest developments may facilitate translational research in the area of stratifying risk of arrhythmias. PMID:25820318

  14. Nandrolone Plus Moderate Exercise Increases the Susceptibility to Lethal Arrhythmias

    PubMed Central

    Ghorbani Baravati, Hamideh; Joukar, Siyavash; Fathpour, Hossein; Kordestani, Zeinab

    2015-01-01

    Background: Until now, no experimental study has directly assessed the arrhythmogenesis of chronic consumption of anabolic androgenic steroids along with moderate-intensity endurance exercise. Objectives: We evaluated the influence of integration of anabolic androgenic steroids along with moderate-intensity endurance exercise on susceptibility to lethal ventricular arrhythmias in rat. Materials and Methods: The animal groups were as follows: control group (CTL); exercise group (EX) which were under 6 weeks of treadmill exercise; nandrolone group (Nan) which received 5 mg/kg of nandrolone decanoate twice a week; vehicle group (Arach) which received Arachis oil (solvent of nandrolone); trained vehicle group (Arach + Ex); and trained nandrolone group (Nan + Ex). One day after ending of the intervention period, arrhythmia was inducted by intravenous infusion of aconitine and ventricular arrhythmias were recorded. Then malondialdehyde (MDA) and glutathione peroxidase (GPX) of heart tissue were measured. Results: Nandrolone, exercise, and their combination were associated with heart hypertrophy. Exercise could prevent the incremental effect of nandrolone on MDA/GPX ratio. Chronic administration of nandrolone with moderate-intensity endurance exercise had no significant effect on blood pressure, heart rate, and basal electrocardiographic parameters. Combination of nandrolone and exercise significantly increased the incidence of ventricular fibrillation (VF) and reduced the VF latency (P < 0.05). Conclusions: The findings suggest that chronic coadministration of nandrolone with moderate-intensity endurance exercise facilitates the VF occurrence in rat. Complementary studies are needed to elucidate the involved mechanisms of this abnormality. PMID:26396972

  15. Arrhythmic risk biomarkers for the assessment of drug cardiotoxicity: from experiments to computer simulations

    PubMed Central

    Corrias, A.; Jie, X.; Romero, L.; Bishop, M. J.; Bernabeu, M.; Pueyo, E.; Rodriguez, B.

    2010-01-01

    In this paper, we illustrate how advanced computational modelling and simulation can be used to investigate drug-induced effects on cardiac electrophysiology and on specific biomarkers of pro-arrhythmic risk. To do so, we first perform a thorough literature review of proposed arrhythmic risk biomarkers from the ionic to the electrocardiogram levels. The review highlights the variety of proposed biomarkers, the complexity of the mechanisms of drug-induced pro-arrhythmia and the existence of significant animal species differences in drug-induced effects on cardiac electrophysiology. Predicting drug-induced pro-arrhythmic risk solely using experiments is challenging both preclinically and clinically, as attested by the rise in the cost of releasing new compounds to the market. Computational modelling and simulation has significantly contributed to the understanding of cardiac electrophysiology and arrhythmias over the last 40 years. In the second part of this paper, we illustrate how state-of-the-art open source computational modelling and simulation tools can be used to simulate multi-scale effects of drug-induced ion channel block in ventricular electrophysiology at the cellular, tissue and whole ventricular levels for different animal species. We believe that the use of computational modelling and simulation in combination with experimental techniques could be a powerful tool for the assessment of drug safety pharmacology. PMID:20478918

  16. Spatiotemporal Permutation Entropy as a Measure for Complexity of Cardiac Arrhythmia

    NASA Astrophysics Data System (ADS)

    Schlemmer, Alexander; Berg, Sebastian; Lilienkamp, Thomas; Luther, Stefan; Parlitz, Ulrich

    2018-05-01

    Permutation entropy (PE) is a robust quantity for measuring the complexity of time series. In the cardiac community it is predominantly used in the context of electrocardiogram (ECG) signal analysis for diagnoses and predictions with a major application found in heart rate variability parameters. In this article we are combining spatial and temporal PE to form a spatiotemporal PE that captures both, complexity of spatial structures and temporal complexity at the same time. We demonstrate that the spatiotemporal PE (STPE) quantifies complexity using two datasets from simulated cardiac arrhythmia and compare it to phase singularity analysis and spatial PE (SPE). These datasets simulate ventricular fibrillation (VF) on a two-dimensional and a three-dimensional medium using the Fenton-Karma model. We show that SPE and STPE are robust against noise and demonstrate its usefulness for extracting complexity features at different spatial scales.

  17. Complex patterns of abnormal heartbeats

    NASA Technical Reports Server (NTRS)

    Schulte-Frohlinde, Verena; Ashkenazy, Yosef; Goldberger, Ary L.; Ivanov, Plamen Ch; Costa, Madalena; Morley-Davies, Adrian; Stanley, H. Eugene; Glass, Leon

    2002-01-01

    Individuals having frequent abnormal heartbeats interspersed with normal heartbeats may be at an increased risk of sudden cardiac death. However, mechanistic understanding of such cardiac arrhythmias is limited. We present a visual and qualitative method to display statistical properties of abnormal heartbeats. We introduce dynamical "heartprints" which reveal characteristic patterns in long clinical records encompassing approximately 10(5) heartbeats and may provide information about underlying mechanisms. We test if these dynamics can be reproduced by model simulations in which abnormal heartbeats are generated (i) randomly, (ii) at a fixed time interval following a preceding normal heartbeat, or (iii) by an independent oscillator that may or may not interact with the normal heartbeat. We compare the results of these three models and test their limitations to comprehensively simulate the statistical features of selected clinical records. This work introduces methods that can be used to test mathematical models of arrhythmogenesis and to develop a new understanding of underlying electrophysiologic mechanisms of cardiac arrhythmia.

  18. Arrhythmia Mechanism and Scaling Effect on the Spectral Properties of Electroanatomical Maps With Manifold Harmonics.

    PubMed

    Sanroman-Junquera, Margarita; Mora-Jimenez, Inmaculada; Garcia-Alberola, Arcadio; Caamano, Antonio J; Trenor, Beatriz; Rojo-Alvarez, Jose L

    2018-04-01

    Spatial and temporal processing of intracardiac electrograms provides relevant information to support the arrhythmia ablation during electrophysiological studies. Current cardiac navigation systems (CNS) and electrocardiographic imaging (ECGI) build detailed 3-D electroanatomical maps (EAM), which represent the spatial anatomical distribution of bioelectrical features, such as activation time or voltage. We present a principled methodology for spectral analysis of both EAM geometry and bioelectrical feature in CNS or ECGI, including their spectral representation, cutoff frequency, or spatial sampling rate (SSR). Existing manifold harmonic techniques for spectral mesh analysis are adapted to account for a fourth dimension, corresponding to the EAM bioelectrical feature. Appropriate scaling is required to address different magnitudes and units. With our approach, simulated and real EAM showed strong SSR dependence on both the arrhythmia mechanism and the cardiac anatomical shape. For instance, high frequencies increased significantly the SSR because of the "early-meets-late" in flutter EAM, compared with the sinus rhythm. Besides, higher frequency components were obtained for the left atrium (more complex anatomy) than for the right atrium in sinus rhythm. The proposed manifold harmonics methodology opens the field toward new signal processing tools for principled EAM spatiofeature analysis in CNS and ECGI, and to an improved knowledge on arrhythmia mechanisms.

  19. Magnetic navigation in adults with atrial isomerism (heterotaxy syndrome) and supraventricular arrhythmias.

    PubMed

    Suman-Horduna, Irina; Babu-Narayan, Sonya V; Ueda, Akiko; Mantziari, Lilian; Gujic, Marko; Marchese, Procolo; Dimopoulos, Konstantinos; Gatzoulis, Michael A; Rigby, Michael L; Ho, Siew Yen; Ernst, Sabine

    2013-06-01

    We analysed the type and mechanism of supraventricular arrhythmias encountered in a series of symptomatic adults with atrial isomerism undergoing catheter ablation procedures. The study population included consecutive adults with atrial isomerism who had previously undergone surgical repair or palliation of the associated anomalies. Patients underwent electrophysiological study for symptomatic arrhythmia in our institution between 2010 and 2012 using magnetic navigation in conjunction with CARTO RMT and three-dimensional (3D) image integration. Eight patients (five females) with a median age of 33 years [interquartile range (IQR) 24-39] were studied. Access to the cardiac chambers of interest was obtained retrogradely via the aorta using remotely navigated magnetic catheters in six patients. Radiofrequency ablation successfully targeted twin atrioventricular (AV) nodal reentrant tachycardia in two patients, atrial fibrillation (AF) in three, focal atrial tachycardia (AT) mainly originating in the left-sided atrium in four patients, and macro-reentrant AT dependent on a right-sided inferior isthmus in three patients. The median fluoroscopy time was 3.0 min (IQR 2-11). After a median follow-up of 10 months (IQR 6-21), five of the ablated patients are free from arrhythmia; two patients experienced episodes of self-terminated AF and AT, respectively, within one month post-ablation; the remaining patient had only non-sustained AT during the electrophysiological study and was managed medically. Various supraventricular tachycardia mechanisms are possible in adults with heterotaxy syndrome, all potentially amenable to radiofrequency ablation. The use of remote magnetic navigation along with 3D mapping facilitated the procedures and resulted in a short radiation time.

  20. In permanent atrial fibrillation, PDE3 reduces force responses to 5‐HT, but PDE3 and PDE4 do not cause the blunting of atrial arrhythmias

    PubMed Central

    Schwarz, Simon; Ravens, Ursula; Knaut, Michael

    2016-01-01

    Abstract Background and Purpose 5‐HT increases force and L‐type Ca2 + current (ICa,L) and causes arrhythmias through 5‐HT4 receptors in human atrium. In permanent atrial fibrillation (peAF), atrial force responses to 5‐HT are blunted, arrhythmias abolished but ICa,L responses only moderately attenuated. We investigated whether, in peAF, this could be due to an increased function of PDE3 and/or PDE4, using the inhibitors cilostamide (300 nM) and rolipram (1 μM) respectively. Experimental Approach Contractile force, arrhythmic contractions and ICa,L were assessed in right atrial trabeculae and myocytes, obtained from patients with sinus rhythm (SR), paroxysmal atrial fibrillation (pAF) and peAF. Key Results Maximum force responses to 5‐HT were reduced to 15% in peAF, but not in pAF. Cilostamide, but not rolipram, increased both the blunted force responses to 5‐HT in peAF and the inotropic potency of 5‐HT fourfold to sevenfold in trabeculae of patients with SR, pAF and peAF. Lusitropic responses to 5‐HT were not decreased in peAF. Responses of ICa,L to 5‐HT did not differ and were unaffected by cilostamide or rolipram in myocytes from patients with SR or peAF. Concurrent cilostamide and rolipram increased 5‐HT's propensity to elicit arrhythmias in trabeculae from patients with SR, but not with peAF. Conclusions and Implications PDE3, but not PDE4, reduced inotropic responses to 5‐HT in peAF, independently of lusitropy and ICa,L, but PDE3 activity was the same as that in patients with SR and pAF. Atrial remodelling in peAF abolished the facilitation of 5‐HT to induce arrhythmias by inhibition of PDE3 plus PDE4. PMID:27238373

  1. MioLab, a rat cardiac contractile force simulator: Applications to teaching cardiac cell physiology and biophysics.

    PubMed

    da Silva, Robson Rodrigues; Bissaco, Marcia Aparecida Silva; Goroso, Daniel Gustavo

    2015-12-01

    Understanding the basic concepts of physiology and biophysics of cardiac cells can be improved by virtual experiments that illustrate the complex excitation-contraction coupling process in cardiac cells. The aim of this study is to propose a rat cardiac myocyte simulator, with which calcium dynamics in excitation-contraction coupling of an isolated cell can be observed. This model has been used in the course "Mathematical Modeling and Simulation of Biological Systems". In this paper we present the didactic utility of the simulator MioLab(®). The simulator enables virtual experiments that can help studying inhibitors and activators in the sarcoplasmic reticulum sodium-calcium exchanger, thus corroborating a better understanding of the effects of medications, which are used to treat arrhythmias, on these compartments. The graphical interfaces were developed not only to facilitate the use of the simulator, but also to promote a constructive learning on the subject, since there are animations and videos for each stage of the simulation. The effectiveness of the simulator was tested by a group of graduate students. Some examples of simulations were presented in order to describe the overall structure of the simulator. Part of these virtual experiments became an activity for Biomedical Engineering graduate students, who evaluated the simulator based on its didactic quality. As a result, students answered a questionnaire on the usability and functionality of the simulator as a teaching tool. All students performed the proposed activities and classified the simulator as an optimal or good learning tool. In their written questions, students indicated as negative characteristics some problems with visualizing graphs; as positive characteristics, they indicated the simulator's didactic function, especially tutorials and videos on the topic of this study. The results show that the simulator complements the study of the physiology and biophysics of the cardiac cell. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  2. The Effects of Nandrolone Decanoate Along with Prolonged Low-Intensity Exercise on Susceptibility to Ventricular Arrhythmias.

    PubMed

    Binayi, Fateme; Joukar, Siyavash; Najafipour, Hamid; Karimi, Abdolah; Karimi, Ali; Abdollahi, Farzane; Masumi, Yaser

    2016-01-01

    We examined the influence of chronic administration of nandrolone decanoate with low-intensity endurance swimming exercise on susceptibility to lethal ventricular arrhythmias in rat. The animal groups included the control group, exercise group (EX), nandrolone group (Nan), vehicle group (Arach), trained vehicle group (Arach + Ex) and trained nandrolone group (Nan + Ex) that treated for 8 weeks. Then, arrhythmia induction was performed by intravenous infusion of aconitine and electrocardiogram recorded. Then, malondialdehyde (MDA), hydroxyproline (HYP) and glutathione peroxidase of heart tissue were measured. Chronic administration of nandrolone with low-intensity endurance swimming exercise had no significant effect on blood pressure, heart rate and basal ECG parameters except RR interval that showed increase (P < 0.05). Low-intensity exercise could prevent the incremental effect of nandrolone on MDA and HYP significantly. It also increased the heart hypertrophy index (P < 0.05) and reduced the abating effect of nandrolone on animal weighting. Nandrolone along with exercise significantly increased the duration of VF (P < 0.05) and reduced the VF latency (P < 0.05). The findings suggest that chronic co-administration of nandrolone with low-intensity endurance swimming exercise to some extent facilitates the occurrence of ventricular fibrillation in rat. Complementary studies are needed to elucidate the involved mechanisms of this abnormality.

  3. Diesel exhaust worsens cardiac conduction instability in dobutamine-challenged spontaneously hypertensive rats

    EPA Science Inventory

    This study demonstrated that diesel exhaust worsened arrhythmia and cardiac function during dobutamine (simulated exercise) challenge in normotensive and hypertensive rats. The data presented here are a mathematically-derived indicator of cardiac risk, which can be used for risk ...

  4. Spectral analysis of sinus arrhythmia - A measure of mental effort

    NASA Technical Reports Server (NTRS)

    Vicente, Kim J.; Craig Thornton, D.; Moray, Neville

    1987-01-01

    The validity of the spectral analysis of sinus arrhythmia as a measure of mental effort was investigated using a computer simulation of a hovercraft piloted along a river as the experimental task. Strong correlation was observed between the subjective effort-ratings and the heart-rate variability (HRV) power spectrum between 0.06 and 0.14 Hz. Significant correlations were observed not only between subjects but, more importantly, within subjects as well, indicating that the spectral analysis of HRV is an accurate measure of the amount of effort being invested by a subject. Results also indicate that the intensity of effort invested by subjects cannot be inferred from the objective ratings of task difficulty or from performance.

  5. Why Arrhythmia Matters

    MedlinePlus

    ... Disease Venous Thromboembolism Aortic Aneurysm More Why Arrhythmia Matters Updated:Dec 21,2016 When the heart's ability ... September 2016. Arrhythmia • Home • About Arrhythmia • Why Arrhythmia Matters • Understand Your Risk for Arrhythmia • Symptoms, Diagnosis & Monitoring ...

  6. Properties and ionic mechanisms of action potential adaptation, restitution, and accommodation in canine epicardium.

    PubMed

    Decker, Keith F; Heijman, Jordi; Silva, Jonathan R; Hund, Thomas J; Rudy, Yoram

    2009-04-01

    Computational models of cardiac myocytes are important tools for understanding ionic mechanisms of arrhythmia. This work presents a new model of the canine epicardial myocyte that reproduces a wide range of experimentally observed rate-dependent behaviors in cardiac cell and tissue, including action potential (AP) duration (APD) adaptation, restitution, and accommodation. Model behavior depends on updated formulations for the 4-aminopyridine-sensitive transient outward current (I(to1)), the slow component of the delayed rectifier K(+) current (I(Ks)), the L-type Ca(2+) channel current (I(Ca,L)), and the Na(+)-K(+) pump current (I(NaK)) fit to data from canine ventricular myocytes. We found that I(to1) plays a limited role in potentiating peak I(Ca,L) and sarcoplasmic reticulum Ca(2+) release for propagated APs but modulates the time course of APD restitution. I(Ks) plays an important role in APD shortening at short diastolic intervals, despite a limited role in AP repolarization at longer cycle lengths. In addition, we found that I(Ca,L) plays a critical role in APD accommodation and rate dependence of APD restitution. Ca(2+) entry via I(Ca,L) at fast rate drives increased Na(+)-Ca(2+) exchanger Ca(2+) extrusion and Na(+) entry, which in turn increases Na(+) extrusion via outward I(NaK). APD accommodation results from this increased outward I(NaK). Our simulation results provide valuable insight into the mechanistic basis of rate-dependent phenomena important for determining the heart's response to rapid and irregular pacing rates (e.g., arrhythmia). Accurate simulation of rate-dependent phenomena and increased understanding of their mechanistic basis will lead to more realistic multicellular simulations of arrhythmia and identification of molecular therapeutic targets.

  7. Regulation of Ion Gradients across Myocardial Ischemic Border Zones: A Biophysical Modelling Analysis

    PubMed Central

    Niederer, Steven

    2013-01-01

    The myocardial ischemic border zone is associated with the initiation and sustenance of arrhythmias. The profile of ionic concentrations across the border zone play a significant role in determining cellular electrophysiology and conductivity, yet their spatial-temporal evolution and regulation are not well understood. To investigate the changes in ion concentrations that regulate cellular electrophysiology, a mathematical model of ion movement in the intra and extracellular space in the presence of ionic, potential and material property heterogeneities was developed. The model simulates the spatial and temporal evolution of concentrations of potassium, sodium, chloride, calcium, hydrogen and bicarbonate ions and carbon dioxide across an ischemic border zone. Ischemia was simulated by sodium-potassium pump inhibition, potassium channel activation and respiratory and metabolic acidosis. The model predicted significant disparities in the width of the border zone for each ionic species, with intracellular sodium and extracellular potassium having discordant gradients, facilitating multiple gradients in cellular properties across the border zone. Extracellular potassium was found to have the largest border zone and this was attributed to the voltage dependence of the potassium channels. The model also predicted the efflux of from the ischemic region due to electrogenic drift and diffusion within the intra and extracellular space, respectively, which contributed to depletion in the ischemic region. PMID:23577101

  8. A computational framework for testing arrhythmia marker sensitivities to model parameters in functionally calibrated populations of atrial cells

    NASA Astrophysics Data System (ADS)

    Vagos, Márcia R.; Arevalo, Hermenegild; de Oliveira, Bernardo Lino; Sundnes, Joakim; Maleckar, Mary M.

    2017-09-01

    Models of cardiac cell electrophysiology are complex non-linear systems which can be used to gain insight into mechanisms of cardiac dynamics in both healthy and pathological conditions. However, the complexity of cardiac models can make mechanistic insight difficult. Moreover, these are typically fitted to averaged experimental data which do not incorporate the variability in observations. Recently, building populations of models to incorporate inter- and intra-subject variability in simulations has been combined with sensitivity analysis (SA) to uncover novel ionic mechanisms and potentially clarify arrhythmogenic behaviors. We used the Koivumäki human atrial cell model to create two populations, representing normal Sinus Rhythm (nSR) and chronic Atrial Fibrillation (cAF), by varying 22 key model parameters. In each population, 14 biomarkers related to the action potential and dynamic restitution were extracted. Populations were calibrated based on distributions of biomarkers to obtain reasonable physiological behavior, and subjected to SA to quantify correlations between model parameters and pro-arrhythmia markers. The two populations showed distinct behaviors under steady state and dynamic pacing. The nSR population revealed greater variability, and more unstable dynamic restitution, as compared to the cAF population, suggesting that simulated cAF remodeling rendered cells more stable to parameter variation and rate adaptation. SA revealed that the biomarkers depended mainly on five ionic currents, with noted differences in sensitivities to these between nSR and cAF. Also, parameters could be selected to produce a model variant with no alternans and unaltered action potential morphology, highlighting that unstable dynamical behavior may be driven by specific cell parameter settings. These results ultimately suggest that arrhythmia maintenance in cAF may not be due to instability in cell membrane excitability, but rather due to tissue-level effects which promote initiation and maintenance of reentrant arrhythmia.

  9. Human In Silico Drug Trials Demonstrate Higher Accuracy than Animal Models in Predicting Clinical Pro-Arrhythmic Cardiotoxicity.

    PubMed

    Passini, Elisa; Britton, Oliver J; Lu, Hua Rong; Rohrbacher, Jutta; Hermans, An N; Gallacher, David J; Greig, Robert J H; Bueno-Orovio, Alfonso; Rodriguez, Blanca

    2017-01-01

    Early prediction of cardiotoxicity is critical for drug development. Current animal models raise ethical and translational questions, and have limited accuracy in clinical risk prediction. Human-based computer models constitute a fast, cheap and potentially effective alternative to experimental assays, also facilitating translation to human. Key challenges include consideration of inter-cellular variability in drug responses and integration of computational and experimental methods in safety pharmacology. Our aim is to evaluate the ability of in silico drug trials in populations of human action potential (AP) models to predict clinical risk of drug-induced arrhythmias based on ion channel information, and to compare simulation results against experimental assays commonly used for drug testing. A control population of 1,213 human ventricular AP models in agreement with experimental recordings was constructed. In silico drug trials were performed for 62 reference compounds at multiple concentrations, using pore-block drug models (IC 50 /Hill coefficient). Drug-induced changes in AP biomarkers were quantified, together with occurrence of repolarization/depolarization abnormalities. Simulation results were used to predict clinical risk based on reports of Torsade de Pointes arrhythmias, and further evaluated in a subset of compounds through comparison with electrocardiograms from rabbit wedge preparations and Ca 2+ -transient recordings in human induced pluripotent stem cell-derived cardiomyocytes (hiPS-CMs). Drug-induced changes in silico vary in magnitude depending on the specific ionic profile of each model in the population, thus allowing to identify cell sub-populations at higher risk of developing abnormal AP phenotypes. Models with low repolarization reserve (increased Ca 2+ /late Na + currents and Na + /Ca 2+ -exchanger, reduced Na + /K + -pump) are highly vulnerable to drug-induced repolarization abnormalities, while those with reduced inward current density (fast/late Na + and Ca 2+ currents) exhibit high susceptibility to depolarization abnormalities. Repolarization abnormalities in silico predict clinical risk for all compounds with 89% accuracy. Drug-induced changes in biomarkers are in overall agreement across different assays: in silico AP duration changes reflect the ones observed in rabbit QT interval and hiPS-CMs Ca 2+ -transient, and simulated upstroke velocity captures variations in rabbit QRS complex. Our results demonstrate that human in silico drug trials constitute a powerful methodology for prediction of clinical pro-arrhythmic cardiotoxicity, ready for integration in the existing drug safety assessment pipelines.

  10. Microwave Treatment for Cardiac Arrhythmias

    NASA Technical Reports Server (NTRS)

    Arndt, G. Dickey (Inventor); Carl, James R. (Inventor); Raffoul, George W. (Inventor); Pacifico, Antonio (Inventor)

    1999-01-01

    Method and apparatus are provided for propagating microwave energy into heart tissues to produce a desired temperature profile therein at tissue depths sufficient for thermally ablating arrhythmogenic cardiac tissue to treat ventricular tachycardia and other arrhythmias while preventing excessive heating of surrounding tissues, organs, and blood. A wide bandwidth double-disk antenna is effective for this purpose over a bandwidth of about six gigahertz. A computer simulation provides initial screening capabilities for an antenna such as antenna, frequency, power level, and power application duration. The simulation also allows optimization of techniques for specific patients or conditions. In operation, microwave energy between about 1 Gigahertz and 12 Gigahertz is applied to monopole microwave radiator having a surface wave limiter. A test setup provides physical testing of microwave radiators to determine the temperature profile created in actual heart tissue or ersatz heart tissue. Saline solution pumped over the heart tissue with a peristaltic pump simulates blood flow. Optical temperature sensors disposed at various tissue depths within the heart tissue detect the temperature profile without creating any electromagnetic interference. The method may be used to produce a desired temperature profile in other body tissues reachable by catheter such as tumors and the like.

  11. Long-Term Simulated Microgravity Causes Cardiac RyR2 Phosphorylation and Arrhythmias in Mice

    PubMed Central

    Respress, Jonathan L.; Gershovich, Pavel M.; Wang, Tiannan; Reynolds, Julia O.; Skapura, Darlene G.; Sutton, Jeffrey P.; Miyake, Christina Y.; Wehrens, Xander H.T.

    2014-01-01

    Background Long-term exposure to microgravity during space flight may lead to cardiac remodeling and rhythm disturbances. In mice, hindlimb unloading (HU) mimics the effects of microgravity and stimulates physiological adaptations, including cardiovascular deconditioning. Recent studies have demonstrated an important role played by changes in intracellular Ca handling in the pathogenesis of heart failure and arrhythmia. In this study, we tested the hypothesis that cardiac remodeling following HU in mice involves abnormal intracellular Ca regulation through the cardiac ryanodine receptor (RyR2). Methods and Results Mice were subjected to HU by tail suspension for 28 to 56 days in order to induce cardiac remodeling (n=15). Control mice (n=19) were treated equally, with the exception of tail suspension. Echocardiography revealed cardiac enlargement and depressed contractility starting at 28 days post-HU versus control. Moreover, mice were more susceptible to pacing-induced ventricular arrhythmias after HU. Ventricular myocytes isolated from HU mice exhibited an increased frequency of spontaneous sarcoplasmic reticulum (SR) Ca release events and enhanced SR Ca leak via RyR2. Western blotting revealed increased RyR2 phosphorylation at S2814, and increased CaMKII auto-phosphorylation at T287, suggesting that CaMKII activation of RyR2 might underlie enhanced SR Ca release in HU mice. Conclusion These data suggest that abnormal intracellular Ca handling, likely due to increased CaMKII phosphorylation of RyR2, plays a role in cardiac remodeling following simulated microgravity in mice. PMID:25227892

  12. Highly trabeculated structure of the human endocardium underlies asymmetrical response to low-energy monophasic shocks

    NASA Astrophysics Data System (ADS)

    Connolly, Adam; Robson, Matthew D.; Schneider, Jürgen; Burton, Rebecca; Plank, Gernot; Bishop, Martin J.

    2017-09-01

    Novel low-energy defibrillation therapies are thought to be driven by virtual-electrodes (VEs), due to the interaction of applied monophasic electric shocks with fine-scale anatomical structures within the heart. Significant inter-species differences in the cardiac (micro)-anatomy exist, however, particularly with respect to the degree of endocardial trabeculations, which may underlie important differences in response to low-energy defibrillation protocols. Understanding the interaction of monophasic electric fields with the specific human micro-anatomy is therefore imperative in facilitating the translation and optimisation of these promising experimental therapies to the clinic. In this study, we sought to investigate how electric fields from implanted devices interact with the highly trabeculated human endocardial surface to better understand shock success in order to help optimise future clinical protocols. A bi-ventricular human computational model was constructed from high resolution (350 μm) ex-vivo MR data, including anatomically accurate endocardial structures. Monophasic shocks were applied between a basal right ventricular catheter and an exterior ground. Shocks of varying strengths were applied with both anodal [positive right ventricle (RV) electrode] and cathodal (negative RV electrode) polarities at different states of tissue refractoriness and during induced arrhythmias. Anodal shocks induced isolated positive VEs at the distal side of "detached" trabeculations, which rapidly spread into hyperpolarised tissue on the surrounding endocardial surfaces following the shock. Anodal shocks thus depolarised more tissue 10 ms after the shock than cathodal shocks where the propagation of activation from VEs induced on the proximal side of "detached" trabeculations was prevented due to refractory endocardium. Anodal shocks increased arrhythmia complexity more than cathodal shocks during failed anti-arrhythmia shocks. In conclusion, multiple detached trabeculations in the human ventricle interact with anodal stimuli to induce multiple secondary sources from VEs, facilitating more rapid shock-induced ventricular excitation compared to cathodal shocks. Such a mechanism may help explain inter-species differences in response to shocks and help to develop novel defibrillation strategies.

  13. Post-operative atrial fibrillation: a maze of mechanisms

    PubMed Central

    Maesen, Bart; Nijs, Jan; Maessen, Jos; Allessie, Maurits; Schotten, Ulrich

    2012-01-01

    Post-operative atrial fibrillation (POAF) is one of the most frequent complications of cardiac surgery and an important predictor of patient morbidity as well as of prolonged hospitalization. It significantly increases costs for hospitalization. Insights into the pathophysiological factors causing POAF have been provided by both experimental and clinical investigations and show that POAF is ‘multi-factorial’. Facilitating factors in the mechanism of the arrhythmia can be classified as acute factors caused by the surgical intervention and chronic factors related to structural heart disease and ageing of the heart. Furthermore, some proarrhythmic mechanisms specifically occur in the setting of POAF. For example, inflammation and beta-adrenergic activation have been shown to play a prominent role in POAF, while these mechanisms are less important in non-surgical AF. More recently, it has been shown that atrial fibrosis and the presence of an electrophysiological substrate capable of maintaining AF also promote the arrhythmia, indicating that POAF has some proarrhythmic mechanisms in common with other forms of AF. The clinical setting of POAF offers numerous opportunities to study its mechanisms. During cardiac surgery, biopsies can be taken and detailed electrophysiological measurements can be performed. Furthermore, the specific time course of POAF, with the delayed onset and the transient character of the arrhythmia, also provides important insight into its mechanisms. This review discusses the mechanistic interaction between predisposing factors and the electrophysiological mechanisms resulting in POAF and their therapeutic implications. PMID:21821851

  14. Recurrence-plot-based measures of complexity and their application to heart-rate-variability data.

    PubMed

    Marwan, Norbert; Wessel, Niels; Meyerfeldt, Udo; Schirdewan, Alexander; Kurths, Jürgen

    2002-08-01

    The knowledge of transitions between regular, laminar or chaotic behaviors is essential to understand the underlying mechanisms behind complex systems. While several linear approaches are often insufficient to describe such processes, there are several nonlinear methods that, however, require rather long time observations. To overcome these difficulties, we propose measures of complexity based on vertical structures in recurrence plots and apply them to the logistic map as well as to heart-rate-variability data. For the logistic map these measures enable us not only to detect transitions between chaotic and periodic states, but also to identify laminar states, i.e., chaos-chaos transitions. The traditional recurrence quantification analysis fails to detect the latter transitions. Applying our measures to the heart-rate-variability data, we are able to detect and quantify the laminar phases before a life-threatening cardiac arrhythmia occurs thereby facilitating a prediction of such an event. Our findings could be of importance for the therapy of malignant cardiac arrhythmias.

  15. Do technical skills correlate with non-technical skills in crisis resource management: a simulation study.

    PubMed

    Riem, N; Boet, S; Bould, M D; Tavares, W; Naik, V N

    2012-11-01

    Both technical skills (TS) and non-technical skills (NTS) are key to ensuring patient safety in acute care practice and effective crisis management. These skills are often taught and assessed separately. We hypothesized that TS and NTS are not independent of each other, and we aimed to evaluate the relationship between TS and NTS during a simulated intraoperative crisis scenario. This study was a retrospective analysis of performances from a previously published work. After institutional ethics approval, 50 anaesthesiology residents managed a simulated crisis scenario of an intraoperative cardiac arrest secondary to a malignant arrhythmia. We used a modified Delphi approach to design a TS checklist, specific for the management of a malignant arrhythmia requiring defibrillation. All scenarios were recorded. Each performance was analysed by four independent experts. For each performance, two experts independently rated the technical performance using the TS checklist, and two other experts independently rated NTS using the Anaesthetists' Non-Technical Skills score. TS and NTS were significantly correlated to each other (r=0.45, P<0.05). During a simulated 5 min resuscitation requiring crisis resource management, our results indicate that TS and NTS are related to one another. This research provides the basis for future studies evaluating the nature of this relationship, the influence of NTS training on the performance of TS, and to determine whether NTS are generic and transferrable between crises that require different TS.

  16. A time-frequency approach for the analysis of normal and arrhythmia cardiac signals.

    PubMed

    Mahmoud, Seedahmed S; Fang, Qiang; Davidović, Dragomir M; Cosic, Irena

    2006-01-01

    Previously, electrocardiogram (ECG) signals have been analyzed in either a time-indexed or spectral form. The reality, is that the ECG and all other biological signals belong to the family of multicomponent nonstationary signals. Due to this reason, the use of time-frequency analysis can be unavoidable for these signals. The Husimi and Wigner distributions are normally used in quantum mechanics for phase space representations of the wavefunction. In this paper, we introduce the Husimi distribution (HD) to analyze the normal and abnormal ECG signals in time-frequency domain. The abnormal cardiac signal was taken from a patient with supraventricular arrhythmia. Simulation results show that the HD has a good performance in the analysis of the ECG signals comparing with the Wigner-Ville distribution (WVD).

  17. Prevalence of atrial arrhythmias in arrhythmogenic right ventricular dysplasia/cardiomyopathy.

    PubMed

    Camm, Christian F; James, Cynthia A; Tichnell, Crystal; Murray, Brittney; Bhonsale, Aditya; te Riele, Anneline S J M; Judge, Daniel P; Tandri, Harikrishna; Calkins, Hugh

    2013-11-01

    Arrhythmogenic right ventricular dysplasia/cardiomyopathy (ARVD/C) is an inherited cardiomyopathy, characterized by right ventricular dysfunction and ventricular arrhythmias. Limited information is available concerning atrial arrhythmias in ARVD/C. The purpose of this study was to characterize spontaneous atrial arrhythmias in a large registry population of ARVD/C patients. Patients (n = 248) from the Johns Hopkins ARVD/C registry who met the diagnostic criteria and had undertaken genotype analysis were included. Medical records of each were reviewed to ascertain incidence and characteristics of atrial arrhythmia episodes. Detailed demographic, phenotypic, and structural information was obtained from registry data. Thirty-five patients with ARVD/C (14%) experienced one or more types of atrial arrhythmia during median follow-up of 5.78 (interquartile range 8.52) years. Atrial fibrillation was the most common atrial arrhythmia, occurring in 80% of ARVD/C patients with atrial arrhythmias. Patients developed atrial arrhythmias at a mean age of 43.0 ± 14.0 years. Atrial arrhythmia patients obtained a total of 22 inappropriate implantable cardioverter-defibrillator shocks during follow-up. Older age at last follow-up (P <.001) and male gender (P = .044) were associated with atrial arrhythmia development. Patients with atrial arrhythmias had a higher occurrence of death (P = .028), heart failure (P <.001), and left atrial enlargement on echocardiography (P = .004). Atrial arrhythmias are common in ARVD/C and present at a younger age than in the general population. They are associated with male gender, increasing age, and left atrial enlargement. Atrial arrhythmias are clinically important as they are associated with inappropriate implantable cardioverter-defibrillator shocks and increased risk of both death and heart failure. © 2013 Heart Rhythm Society. All rights reserved.

  18. Atrial Fibrillation Medications

    MedlinePlus

    ... for Heart.org Arrhythmia About Arrhythmia Why Arrhythmia Matters Understand Your Risk for Arrhythmia Symptoms, Diagnosis & Monitoring ... How HBP Harms Your Health Make Changes That Matter Find HBP Tools & Resources Stroke Vascular Health Peripheral ...

  19. Patient's Guide to Taking Warfarin

    MedlinePlus

    ... for Heart.org Arrhythmia About Arrhythmia Why Arrhythmia Matters Understand Your Risk for Arrhythmia Symptoms, Diagnosis & Monitoring ... How HBP Harms Your Health Make Changes That Matter Find HBP Tools & Resources Stroke Vascular Health Peripheral ...

  20. Heart Attack Symptoms in Women

    MedlinePlus

    ... for Heart.org Arrhythmia About Arrhythmia Why Arrhythmia Matters Understand Your Risk for Arrhythmia Symptoms, Diagnosis & Monitoring ... How HBP Harms Your Health Make Changes That Matter Find HBP Tools & Resources Stroke Vascular Health Peripheral ...

  1. Understand Your Risk for Heart Failure

    MedlinePlus

    ... Heart.org Arrhythmia About Arrhythmia Why Arrhythmia Matters Understand Your Risk for Arrhythmia Symptoms, Diagnosis & Monitoring of ... Heart Defects The Impact of Congenital Heart Defects Understand Your Risk for Congenital Heart Defects Symptoms & Diagnosis ...

  2. Prevention and Treatment of Arrhythmia

    MedlinePlus

    ... your pulse – especially if you have an artificial pacemaker. Put the second and third fingers of one ... Ablation Devices for Arrhythmia - Implantable Cardioverter Defibrillator (ICD) - Pacemaker Treating Arrhythmias in Children • Arrhythmia Tools & Resources Watch, ...

  3. Single Photon Emission Computed Tomography (SPECT)

    MedlinePlus

    ... for Heart.org Arrhythmia About Arrhythmia Why Arrhythmia Matters Understand Your Risk for Arrhythmia Symptoms, Diagnosis & Monitoring ... How HBP Harms Your Health Make Changes That Matter Find HBP Tools & Resources Stroke Vascular Health Peripheral ...

  4. Angina in Women Can Be Different Than Men

    MedlinePlus

    ... for Heart.org Arrhythmia About Arrhythmia Why Arrhythmia Matters Understand Your Risk for Arrhythmia Symptoms, Diagnosis & Monitoring ... How HBP Harms Your Health Make Changes That Matter Find HBP Tools & Resources Stroke Vascular Health Peripheral ...

  5. Arrhythmias in Adults with Congenital Heart Disease: What Are Risk Factors for Specific Arrhythmias?

    PubMed

    Loomba, Rohit S; Buelow, Matthew W; Aggarwal, Saurabh; Arora, Rohit R; Kovach, Joshua; Ginde, Salil

    2017-04-01

    An increasing number of patients with congenital heart disease are now surviving into adulthood. This has also led to the emergence of complications from the underlying congenital heart disease, related surgical interventions, and associated combordities. While the prevalence of particular arrhythmias with specific congenital heart disease has been previously described, a detailed analysis of all lesions and a large number of comorbidities has not been previously published. Admissions with congenital heart disease were identified in the National Inpatient Sample. Associated comorbidities were also identified for these patients. Univariate analysis was done to compare those risk factors associated with specific arrhythmias in the setting of congenital heart disease. Next, regression analysis was done to identify what patient characteristics and comorbidities were associated with increased risk of specific arrhythmias. A total of 52,725,227 admissions were included in the analysis. Of these, 109,168 (0.21%) had congenital heart disease. Of those with congenital heart disease, 27,088 (25%) had an arrhythmia at some point. The most common arrhythmia in those with congenital heart disease was atrial fibrillation, which was noted in 86% of those with arrhythmia followed by atrial flutter which was noted in 20% of those with congenital heart disease. The largest burden of arrhythmia was found to be in those with tricuspid atresia with a 51% prevalence of arrhythmia in this group followed by Ebstein anomaly which had an arrhythmia prevalence of 39%. Increasing age, male gender, double outlet right ventricle, atrioventricular septal defect, heart failure, obstructive sleep apnea, transposition of the great arteries, congenitally corrected transposition, and tetralogy of Fallot were frequently noted to be independent risk factors of specific arrhythmias. Approximately, 25% of adult admissions with congenital heart disease are associated with arrhythmia. The burden of arrhythmia varies by the specific lesion and other risk factors as well. Understanding of these can help in risk stratification and can help devise strategies to lower this risk. © 2016 Wiley Periodicals, Inc.

  6. Physiological Regulation and Fearfulness as Predictors of Young Children's Empathy-Related Reactions

    ERIC Educational Resources Information Center

    Liew, Jeffrey; Eisenberg, Nancy; Spinrad, Tracy L.; Eggum, Natalie D.; Haugen, R. G.; Kupfer, Anne; Reiser, Mark R.; Smith, Cynthia L.; Lemery-Chalfant, Kathryn; Baham, Melinda E.

    2011-01-01

    Indices of physiological regulation (i.e., resting respiratory sinus arrhythmia [RSA] and RSA suppression) and observed fearfulness were tested as predictors of empathy-related reactions to an unfamiliar person's simulated distress within and across 18 (T1, N = 247) and 30 (T2, N = 216) months of age. Controlling for T1 helping, high RSA…

  7. Management of unstable arrhythmias in cardiogenic shock.

    PubMed

    Saidi, Abdulfattah; Akoum, Nazem; Bader, Feras

    2011-08-01

    Atrial and ventricular arrhythmias commonly arise in the setting of cardiogenic shock and often result in hemodynamic deterioration. Causative factors include myocardial ischemia, volume overload, and metabolic disturbances. Correcting these factors plays an important role in managing arrhythmias in this setting. Ventricular arrhythmias are more ominous compared to atrial arrhythmias but both require prompt intervention with electrical shock and anti-arrhythmic drug suppression. Coronary reperfusion is key to improving survival, including reducing the risk of sudden cardiac arrest, in acute myocardial infarction. Case series have also demonstrated the value of intra-aortic balloon pump counter-pulsation in suppressing ventricular arrhythmias in cardiogenic shock. The mechanism of arrhythmia suppression may be due to improved coronary perfusion and afterload reduction. Percutaneous ventricular assist device placement may be effective in this setting; however, data addressing this specific endpoint are lacking. Anti-arrhythmic drug options for ventricular and atrial arrhythmia suppression, in the setting of cardiogenic shock, are relatively limited. Common class I agents are excluded due to the inherent abnormal cardiac structure and function in the setting of cardiogenic shock. Class III drug options include dofetilide and amiodarone. The other Class III agents, sotalol and dronedarone, are excluded due to associated mortality observed in the SWORD and ANDROMEDA trials, respectively. Dofetilide is renally excreted and causes QT interval prolongation. Care should be taken to avoid excessive drug accumulation due to poor kidney perfusion and function. Dofetilide is approved for use for atrial arrhythmias and has not been studied for ventricular arrhythmia suppression. The DIAMOND-CHF trial established its safety in the setting of heart failure. Amiodarone is very effective in suppressing both atrial and ventricular arrhythmias. It is often the drug of choice in heart failure. Its off-label use for atrial arrhythmias is very common. Care should be taken with intravenous amiodarone to avoid hypotension.

  8. Impact of remote monitoring on the management of arrhythmias in patients with implantable cardioverter-defibrillator.

    PubMed

    Marcantoni, Lina; Toselli, Tiziano; Urso, Giulia; Pratola, Claudio; Ceconi, Claudio; Bertini, Matteo

    2015-11-01

    In the last decade, there has been an exponential increase in cardioverter-defibrillator (ICD) implants. Remote monitoring systems, allow daily follow-ups of patients with ICD. To evaluate the impact of remote monitoring on the management of cardiovascular events associated with supraventricular and ventricular arrhythmias during long-term follow-up. A total of 207 patients undergoing ICD implantation/replacement were enrolled: 79 patients received remote monitoring systems and were followed up every 12 months, and 128 patients were followed up conventionally every 6 months. All patients were followed up and monitored for the occurrence of supraventricular and ventricular arrhythmia-related cardiovascular events (ICD shocks and/or hospitalizations). During a median follow-up of 842 days (interquartile range 476-1288 days), 32 (15.5%) patients experienced supraventricular arrhythmia-related events and 51 (24.6%) patients experienced ventricular arrhythmia-related events. Remote monitoring had a significant role in the reduction of supraventricular arrhythmia-related events, but it had no effect on ventricular arrhythmia-related events. In multivariable analysis, remote monitoring remained as an independent protective factor, reducing the risk of supraventricular arrhythmia-related events of 67% [hazard ratio, 0.33; 95% confidence interval (CI), 0.13-0.82; P = 0.017]. Remote monitoring systems improved outcomes in patients with supraventricular arrhythmias by reducing the risk of cardiovascular events, but no benefits were observed in patients with ventricular arrhythmias.

  9. Bifurcation diagrams of frequency dependence of repolarization during long QT syndrome using the Luo-Rudy model of cardiac repolarization

    NASA Astrophysics Data System (ADS)

    Bondarenko, V. E.; Doedel, E. J.; Rasmusson, R. L.

    2000-02-01

    We applied bifurcation analysis to the Luo-Rudy model of the guinea pig cardiac ventricular cell to investigate the behavior of repolarization in response to a simulated form of inherited arrhythmia, long QT syndrome. In this paper, we simulate pathological changes in cardiac repolarization through reductions in IKr. Decreased expression of this current has been linked to an inherited form of long QT syndrome which results in a high mortality, presumably due to sudden cardiac death from ventricular fibrillation.

  10. Features of Chaotic Transients in Excitable Media Governed by Spiral and Scroll Waves

    NASA Astrophysics Data System (ADS)

    Lilienkamp, Thomas; Christoph, Jan; Parlitz, Ulrich

    2017-08-01

    In excitable media, chaotic dynamics governed by spiral or scroll waves is often not persistent but transient. Using extensive simulations employing different mathematical models we identify a specific type-II supertransient by an exponential increase of transient lifetimes with the system size in 2D and an investigation of the dynamics (number and lifetime of spiral waves, Kaplan-Yorke dimension). In 3D, simulations exhibit an increase of transient lifetimes and filament lengths only above a critical thickness. Finally, potential implications for understanding cardiac arrhythmias are discussed.

  11. Evidence Based Review: Risk of Cardiac Rhythm Problems During Spaceflight

    NASA Technical Reports Server (NTRS)

    Platts, Steven H.; Stenger, Michael B.; Phillips, Tiffany R.; Brown, Angela K.; Arzeno, Natalia M.; Levine, Benjamin; Summers, Richard

    2009-01-01

    Very little research has systematically evaluated the prevalence (or potential risk) of cardiac arrhythmias during space flight. There are several observational reports of non life-threatening but potentially concerning arrhythmias. At least two potential risk factors for arrhythmias have been reported either during or immediately after space flight: cardiac atrophy and a prolonged QTc interval. The potential severity of the mission impact of a serious arrhythmia requires that a systematic evaluation be conducted of the risk of arrhythmia due to space flight.

  12. 21 CFR 870.1025 - Arrhythmia detector and alarm (including ST-segment measurement and alarm).

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Arrhythmia detector and alarm (including ST... Diagnostic Devices § 870.1025 Arrhythmia detector and alarm (including ST-segment measurement and alarm). (a) Identification. The arrhythmia detector and alarm device monitors an electrocardiogram and is designed to produce...

  13. 21 CFR 870.1025 - Arrhythmia detector and alarm (including ST-segment measurement and alarm).

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Arrhythmia detector and alarm (including ST... Diagnostic Devices § 870.1025 Arrhythmia detector and alarm (including ST-segment measurement and alarm). (a) Identification. The arrhythmia detector and alarm device monitors an electrocardiogram and is designed to produce...

  14. 21 CFR 870.1025 - Arrhythmia detector and alarm (including ST-segment measurement and alarm).

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Arrhythmia detector and alarm (including ST... Diagnostic Devices § 870.1025 Arrhythmia detector and alarm (including ST-segment measurement and alarm). (a) Identification. The arrhythmia detector and alarm device monitors an electrocardiogram and is designed to produce...

  15. The Use of Automated External Defibrillators in Infants: A Report From the American Red Cross Scientific Advisory Council.

    PubMed

    Rossano, Joseph W; Jones, Wendell E; Lerakis, Stamatios; Millin, Michael G; Nemeth, Ira; Cassan, Pascal; Shook, Joan; Kennedy, Siobán; Markenson, David; Bradley, Richard N

    2015-07-01

    Automated external defibrillators (AEDs) have been used successfully in many populations to improve survival for out-of-hospital cardiac arrest. While ventricular fibrillation and pulseless ventricular tachycardia are more prevalent in adults, these arrhythmias do occur in infants. The Scientific Advisory Council of the American Red Cross reviewed the literature on the use of AEDs in infants in order to make recommendations on use in the population. The Cochrane library and PubMed were searched for studies that included AEDs in infants, any external defibrillation in infants, and simulation studies of algorithms used by AEDs on pediatric arrhythmias. There were 4 studies on the accuracy of AEDs in recognizing pediatric arrhythmias. Case reports (n = 2) demonstrated successful use of AED in infants, and a retrospective review (n = 1) of pediatric pads for AEDs included infants. Six studies addressed defibrillation dosages used. The algorithms used by AEDs had high sensitivity and specificity for pediatric arrhythmias and very rarely recommended a shock inappropriately. The energy doses delivered by AEDs were high, although in the range that have been used in out-of-hospital arrest. In addition, there are data to suggest that 2 to 4 J/kg may not be effective defibrillation doses for many children. In the absence of prompt defibrillation for ventricular fibrillation or pulseless ventricular tachycardia, survival is unlikely. Automated external defibrillators should be used in infants with suspected cardiac arrest, if a manual defibrillator with a trained rescuer is not immediately available. Automated external defibrillators that attenuate the energy dose (eg, via application of pediatric pads) are recommended for infants. If an AED with pediatric pads is not available, the AED with adult pads should be used.

  16. Nonpharmacologic control of postoperative supraventricular arrhythmias using AV nodal fat pad stimulation in a young animal open heart surgical model.

    PubMed

    Moak, Jeffrey P; Mercader, Marco A; He, Dingchao; Trachiotis, Gregory; Langert, Joshua; Blicharz, Andy; Montaque, Erin; Li, Xiyan; Cheng, Yao I; McCarter, Robert; Bornzin, Gene A; Martin, Gerard R; Jonas, Richard A

    2013-06-01

    Supraventricular arrhythmias (junctional ectopic tachycardia [JET] and atrial tachyarrhythmias) frequently complicate recovery from open heart surgery in children and can be difficult to manage. Medical treatment of JET can result in significant morbidity. Our goal was to develop a nonpharmacological approach using autonomic stimulation of selective fat pad (FP) regions of the heart in a young canine model of open heart surgery to control 2 common postoperative supraventricular arrhythmias. Eight mongrel dogs, varying in age from 5 to 8 months and weighting 22±4 kg, underwent open heart surgery replicating a nontransannular approach to tetralogy of Fallot repair. Neural stimulation of the right inferior FP was used to control the ventricular response to supraventricular arrhythmias. Right inferior FP stimulation decreased baseline AV nodal conduction without altering sinus cycle length. AV node Wenckebach cycle length prolonged from 270±33 to 352±89 ms, P=0.02. Atrial fibrillation occurred in 7 animals, simulating a rapid atrial tachyarrhythmias. FP stimulation slowed the ventricular response rate from 166±58 to 63±29 beats per minute, P<0.001. Postoperative JET occurred in 7 dogs. FP stimulation slowed the ventricular rate during postoperative JET from 148±31 to 106±32 beats per minute, P<0.001, and restored sinus rhythm in 7/7 dogs. Right inferior FP stimulation had a selective effect on the AV node, and slowed the ventricular rate during postoperative JET and atrial tachyarrhythmias in our young canine open heart surgery model. FP stimulation may be a useful new technique for managing children with JET and atrial tachyarrhythmias.

  17. Clinical Profile of Cardiac Arrhythmias in Children Attending the Out Patient Department of a Tertiary Paediatric Care Centre in Chennai

    PubMed Central

    Sundararajan, Premkumar; Sangaralingam, Thangavelu

    2016-01-01

    Introduction The presentation of symptoms of paediatric arrhythmias vary depending on the age and underlying heart disease. Physical examination of children with important arrhythmias may be entirely normal. Aim Aim is to study the characteristics of cardiac arrhythmias in paediatric patients in a tertiary paediatric care centre in Chennai, India. Materials and Methods The participants (n=60) were from birth to 12 years of age. Patients with sinus arrhythmias, sinus tachycardia and sinus bradycardia were excluded. Proportions of various parameters of interest like clinical features, age and sex distribution and underlying heart disease of children presenting with cardiac arrhythmias were arrived. Statistical analysis was performed using SPSS version 16.0. Results Ventricular ectopics were the most common type of arrhythmias observed in the present study followed by Sinus Node Dysfunction (SND). The most common type of SND was sino atrial arrest. Supra ventricular tachycardia was the most frequently sustained tachyarrhythmia in the present study. An increased association of WPW (Wolf Parkinson White Syndrome) with specific congenital cardiac defects was noted. Conclusion Cardiac arrhythmias in children can present at anytime from fetal life to adolescence and their recognition requires high index of suspicion. While majority of children with arrhythmias have structurally normal heart, they are frequently encountered in children with underlying heart disease. Treatment of paediatric arrhythmias should be guided by the severity of the patient, the structure and function of the heart. PMID:28208963

  18. Dynamics of spiral waves rotating around an obstacle and the existence of a minimal obstacle

    NASA Astrophysics Data System (ADS)

    Gao, Xiang; Feng, Xia; Li, Teng-Chao; Qu, Shixian; Wang, Xingang; Zhang, Hong

    2017-05-01

    Pinning of vortices by obstacles plays an important role in various systems. In the heart, anatomical reentry is created when a vortex, also known as the spiral wave, is pinned to an anatomical obstacle, leading to a class of physiologically very important arrhythmias. Previous analyses of its dynamics and instability provide fine estimates in some special circumstances, such as large obstacles or weak excitabilities. Here, to expand theoretical analyses to all circumstances, we propose a general theory whose results quantitatively agree with direct numerical simulations. In particular, when obstacles are small and pinned spiral waves are destabilized, an accurate explanation of the instability in two-dimensional media is provided by the usage of a mapping rule and dimension reduction. The implications of our results are to better understand the mechanism of arrhythmia and thus improve its early prevention.

  19. Quasiperiodicity route to chaos in cardiac conduction model

    NASA Astrophysics Data System (ADS)

    Quiroz-Juárez, M. A.; Vázquez-Medina, R.; Ryzhii, E.; Ryzhii, M.; Aragón, J. L.

    2017-01-01

    It has been suggested that cardiac arrhythmias are instances of chaos. In particular that the ventricular fibrillation is a form of spatio-temporal chaos that arises from normal rhythm through a quasi-periodicity or Ruelle-Takens-Newhouse route to chaos. In this work, we modify the heterogeneous oscillator model of cardiac conduction system proposed in Ref. [Ryzhii E, Ryzhii M. A heterogeneous coupled oscillator model for simulation of ECG signals. Comput Meth Prog Bio 2014;117(1):40-49. doi:10.1016/j.cmpb.2014.04.009.], by including an ectopic pacemaker that stimulates the ventricular muscle to model arrhythmias. With this modification, the transition from normal rhythm to ventricular fibrillation is controlled by a single parameter. We show that this transition follows the so-called torus of quasi-periodic route to chaos, as verified by using numerical tools such as power spectrum and largest Lyapunov exponent.

  20. Importance of the atrial channel for ventricular arrhythmia therapy in the dual chamber implantable cardioverter defibrillator.

    PubMed

    Dijkman, B; Wellens, H J

    2000-12-01

    Performance of dual chamber implantable cardioverter defibrillator (ICD) systems has been judged based on functioning of the ventricular tachycardia:supraventricular tachycardia (VT:SVT) discrimination criteria and DDD pacing. The purpose of this study was to evaluate the use of dual chamber diagnostics to improve the electrical and antiarrhythmic therapy of ventricular arrhythmias. Information about atrial and ventricular rhythm in relation to ventricular arrhythmia occurrence and therapy was evaluated in 724 spontaneous arrhythmia episodes detected and treated by three types of dual chamber ICDs in 41 patients with structural heart disease. Device programming was based on clinically documented and induced ventricular arrhythmias. In ambulatory patients, sinus tachycardia preceded ventricular arrhythmias more often than in the hospital during exercise testing. The incidence of these VTs could be reduced by increasing the dose of a beta-blocking agent in only two patients. In five patients in whom sinus tachycardia developed after onset of hemodynamic stable VT, propranolol was more effective than Class III antiarrhythmics combined with another beta-blocking agent with regard to the incidence of VT and pace termination. In all but three cases, atrial arrhythmias were present for a longer time before the onset of ventricular arrhythmias. During atrial arrhythmias, fast ventricular rates before the onset of ventricular rate were observed more often than RR irregularities and short-long RR sequences. Dual chamber diagnostics allowed proper interpretation of detection and therapy outcome in patients with different types of ventricular arrhythmia. The advantages of the dual chamber ICD system go further than avoiding the shortcomings of the single chamber system. Information from the atrial chamber allows better device programming and individualization of drug therapy for ventricular arrhythmia.

  1. The Association between Nocturnal Cardiac Arrhythmias and Sleep-Disordered Breathing: The DREAM Study.

    PubMed

    Selim, Bernardo J; Koo, Brian B; Qin, Li; Jeon, Sangchoon; Won, Christine; Redeker, Nancy S; Lampert, Rachel J; Concato, John P; Bravata, Dawn M; Ferguson, Jared; Strohl, Kingman; Bennett, Adam; Zinchuk, Andrey; Yaggi, Henry K

    2016-06-15

    To determine whether sleep-disordered breathing (SDB) is associated with cardiac arrhythmia in a clinic-based population with multiple cardiovascular comorbidities and severe SDB. This was a cross-sectional analysis of 697 veterans who underwent polysomnography for suspected SDB. SDB was categorized according to the apnea-hypopnea index (AHI): none (AHI < 5), mild (5 ≥ AHI < 15), and moderate-severe (AHI ≥ 15). Nocturnal cardiac arrhythmias consisted of: (1) complex ventricular ectopy, (CVE: non-sustained ventricular tachycardia, bigeminy, trigeminy, or quadrigeminy), (2) combined supraventricular tachycardia, (CST: atrial fibrillation or supraventricular tachycardia), (3) intraventricular conduction delay (ICD), (4) tachyarrhythmias (ventricular and supraventricular), and (5) any cardiac arrhythmia. Unadjusted, adjusted logistic regression, and Cochran-Armitage testing examined the association between SDB and cardiac arrhythmias. Linear regression models explored the association between hypoxia, arousals, and cardiac arrhythmias. Compared to those without SDB, patients with moderate-severe SDB had almost three-fold unadjusted odds of any cardiac arrhythmia (2.94; CI 95%, 2.01-4.30; p < 0.0001), two-fold odds of tachyarrhythmias (2.16; CI 95%,1.47-3.18; p = 0.0011), two-fold odds of CVE (2.01; 1.36-2.96; p = 0.003), and two-fold odds of ICD (2.50; 1.58-3.95; p = 0.001). A linear trend was identified between SDB severity and all cardiac arrhythmia subtypes (p value linear trend < 0.0001). After adjusting for age, BMI, gender, and cardiovascular diseases, moderate-severe SDB patients had twice the odds of having nocturnal cardiac arrhythmias (2.24; 1.48-3.39; p = 0.004). Frequency of obstructive respiratory events and hypoxia were strong predictors of arrhythmia risk. SDB is independently associated with nocturnal cardiac arrhythmias. Increasing severity of SDB was associated with an increasing risk for any cardiac arrhythmia. © 2016 American Academy of Sleep Medicine.

  2. Increasing Prevalence of Atrial Fibrillation and Permanent Atrial Arrhythmias in Congenital Heart Disease.

    PubMed

    Labombarda, Fabien; Hamilton, Robert; Shohoudi, Azadeh; Aboulhosn, Jamil; Broberg, Craig S; Chaix, Marie A; Cohen, Scott; Cook, Stephen; Dore, Annie; Fernandes, Susan M; Fournier, Anne; Kay, Joseph; Macle, Laurent; Mondésert, Blandine; Mongeon, François-Pierre; Opotowsky, Alexander R; Proietti, Anna; Rivard, Lena; Ting, Jennifer; Thibault, Bernard; Zaidi, Ali; Khairy, Paul

    2017-08-15

    Atrial arrhythmias are the most common complication encountered in the growing and aging population with congenital heart disease. This study sought to assess the types and patterns of atrial arrhythmias, associated factors, and age-related trends. A multicenter cohort study enrolled 482 patients with congenital heart disease and atrial arrhythmias, age 32.0 ± 18.0 years, 45.2% female, from 12 North American centers. Qualifying arrhythmias were classified by a blinded adjudicating committee. The most common presenting arrhythmia was intra-atrial re-entrant tachycardia (IART) (61.6%), followed by atrial fibrillation (28.8%), and focal atrial tachycardia (9.5%). The proportion of arrhythmias due to IART increased with congenital heart disease complexity from 47.2% to 62.1% to 67.0% in patients with simple, moderate, and complex defects, respectively (p = 0.0013). Atrial fibrillation increased with age to surpass IART as the most common arrhythmia in those ≥50 years of age (51.2% vs. 44.2%; p < 0.0001). Older age (odds ratio [OR]: 1.024 per year; 95% confidence interval [CI]: 1.010 to 1.039; p = 0.001) and hypertension (OR: 2.00; 95% CI: 1.08 to 3.71; p = 0.029) were independently associated with atrial fibrillation. During a mean follow-up of 11.3 ± 9.4 years, the predominant arrhythmia pattern was paroxysmal in 62.3%, persistent in 28.2%, and permanent in 9.5%. Permanent atrial arrhythmias increased with age from 3.1% to 22.6% in patients <20 years to ≥50 years, respectively (p < 0.0001). IART is the most common presenting atrial arrhythmia in patients with congenital heart disease, with a predominantly paroxysmal pattern. However, atrial fibrillation increases in prevalence and atrial arrhythmias progressively become permanent as the population ages. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  3. In silico prediction of drug therapy in catecholaminergic polymorphic ventricular tachycardia

    PubMed Central

    Yang, Pei‐Chi; Moreno, Jonathan D.; Miyake, Christina Y.; Vaughn‐Behrens, Steven B.; Jeng, Mao‐Tsuen; Grandi, Eleonora; Wehrens, Xander H. T.; Noskov, Sergei Y.

    2016-01-01

    Key points The mechanism of therapeutic efficacy of flecainide for catecholaminergic polymorphic ventricular tachycardia (CPVT) is unclear.Model predictions suggest that Na+ channel effects are insufficient to explain flecainide efficacy in CPVT.This study represents a first step toward predicting therapeutic mechanisms of drug efficacy in the setting of CPVT and then using these mechanisms to guide modelling and simulation to predict alternative drug therapies. Abstract Catecholaminergic polymorphic ventricular tachycardia (CPVT) is an inherited arrhythmia syndrome characterized by fatal ventricular arrhythmias in structurally normal hearts during β‐adrenergic stimulation. Current treatment strategies include β‐blockade, flecainide and ICD implementation – none of which is fully effective and each comes with associated risk. Recently, flecainide has gained considerable interest in CPVT treatment, but its mechanism of action for therapeutic efficacy is unclear. In this study, we performed in silico mutagenesis to construct a CPVT model and then used a computational modelling and simulation approach to make predictions of drug mechanisms and efficacy in the setting of CPVT. Experiments were carried out to validate model results. Our simulations revealed that Na+ channel effects are insufficient to explain flecainide efficacy in CPVT. The pure Na+ channel blocker lidocaine and the antianginal ranolazine were additionally tested and also found to be ineffective. When we tested lower dose combination therapy with flecainide, β‐blockade and CaMKII inhibition, our model predicted superior therapeutic efficacy than with flecainide monotherapy. Simulations indicate a polytherapeutic approach may mitigate side‐effects and proarrhythmic potential plaguing CPVT pharmacological management today. Importantly, our prediction of a novel polytherapy for CPVT was confirmed experimentally. Our simulations suggest that flecainide therapeutic efficacy in CPVT is unlikely to derive from primary interactions with the Na+ channel, and benefit may be gained from an alternative multi‐drug regimen. PMID:26515697

  4. Catheter ablation for premature ventricular contractions and ventricular tachycardia in patients with heart failure.

    PubMed

    Kumar, Saurabh; Stevenson, William G; John, Roy M

    2014-09-01

    Ventricular arrhythmias (VA) are a significant contributor to morbidity and mortality in patients with heart failure (HF). Implantable cardioverter defibrillators are effective in reducing mortality, but do not prevent arrhythmia recurrence. There is increasing recognition that frequent premature ventricular contractions or repetitive ventricular tachycardia may also lead to new onset ventricular dysfunction or deterioration of ventricular function in patients with pre-existing HF. Suppression of the arrhythmia may lead to recovery of ventricular function. Catheter ablation has emerged as a safe and effective treatment option for reducing arrhythmia recurrence and for suppression of PVCs but its efficacy is governed by the nature of the arrhythmias, the underlying HF substrate and the accessibility of the arrhythmia substrates to ablation.

  5. Slow adaptation of ventricular repolarization as a cause of arrhythmia?

    PubMed

    Bueno-Orovio, A; Hanson, B M; Gill, J S; Taggart, P; Rodriguez, B

    2014-01-01

    This article is part of the Focus Theme of Methods of Information in Medicine on "Biosignal Interpretation: Advanced Methods for Studying Cardiovascular and Respiratory Systems". Adaptation of the QT-interval to changes in heart rate reflects on the body-surface electrocardiogram the adaptation of action potential duration (APD) at the cellular level. The initial fast phase of APD adaptation has been shown to modulate the arrhythmia substrate. Whether the slow phase is potentially proarrhythmic remains unclear. To analyze in-vivo human data and use computer simulations to examine effects of the slow APD adaptation phase on dispersion of repolarization and reentry in the human ventricle. Electrograms were acquired from 10 left and 10 right ventricle (LV/RV) endocardial sites in 15 patients with normal ventricles during RV pacing. Activation-recovery intervals, as a surrogate for APD, were measured during a sustained increase in heart rate. Observed dynamics were studied using computer simulations of human tissue electrophysiology. Spatial heterogeneity of rate adaptation was observed in all patients. Inhomogeneity in slow APD adaptation time constants (Δτ(s)) was greater in LV than RV (Δτ(s)(LV) = 31.8 ± 13.2, Δτ(s)(RV) = 19.0 ± 12.8 s , P< 0.01). Simulations showed that altering local slow time constants of adaptation was sufficient to convert partial wavefront block to block with successful reentry. Using electrophysiological data acquired in-vivo in human and computer simulations, we identify heterogeneity in the slow phase of APD adaptation as an important component of arrhythmogenesis.

  6. Diagnosis and therapy of atrial tachyarrhythmias in the dual chamber implantable cardioverter defibrillator.

    PubMed

    Dijkman, B; Wellens, H J

    2000-11-01

    Devices capable of monitoring and treating atrial tachyarrhythmias provide information about the natural history of the arrhythmias and potentially can influence their natural course by electrical therapy early after onset. Types of atrial arrhythmias and efficacy of device therapies were evaluated in 30 patients implanted with the Medtronic model 7250 Jewel AF implantable cardioverter defibrillator (ICD). All patients had structural heart disease and documented sustained ventricular and atrial arrhythmias (27 with atrial fibrillation [AF]) before implant. Twenty patients were taking amiodarone, and three were taking sotalol. During 20+/-10 months of follow-up, 600 atrial arrhythmia recurrences were documented in 50% of patients. AF was diagnosed in 19%, fast polymorphic atrial tachycardia (AT) in 20%, fast monomorphic AT in 57%, and slow AT in 4% of episodes. The two adaptive pacing therapies, burst and ramp, together with the 50-Hz burst, were successful in 57% of detected atrial arrhythmias. Burst and ramp were responsible for 49% and 50-Hz burst for 51% of successfully treated arrhythmias; 33% of the episodes terminated spontaneously. No ventricular proarrhythmia was observed due to atrial pacing therapies. In 30% of episodes, dual chamber pacing was required due to post termination bradycardia. Atrial arrhythmia recurrences in patients with dilated cardiomyopathy were not amenable to pacing therapies. Several aspects of atrial arrhythmia diagnosis, therapy, and documentation that are specific for functioning of the Jewel AF are discussed. Atrial arrhythmias in ICD patients with diseased hearts who are taking Class III antiarrhythmics frequently had longer cycle lengths than AF. Half of these arrhythmias could be terminated with pacing therapies; one third terminated spontaneously.

  7. Proposition of novel classification approach and features for improved real-time arrhythmia monitoring.

    PubMed

    Kim, Yoon Jae; Heo, Jeong; Park, Kwang Suk; Kim, Sungwan

    2016-08-01

    Arrhythmia refers to a group of conditions in which the heartbeat is irregular, fast, or slow due to abnormal electrical activity in the heart. Some types of arrhythmia such as ventricular fibrillation may result in cardiac arrest or death. Thus, arrhythmia detection becomes an important issue, and various studies have been conducted. Additionally, an arrhythmia detection algorithm for portable devices such as mobile phones has recently been developed because of increasing interest in e-health care. This paper proposes a novel classification approach and features, which are validated for improved real-time arrhythmia monitoring. The classification approach that was employed for arrhythmia detection is based on the concept of ensemble learning and the Taguchi method and has the advantage of being accurate and computationally efficient. The electrocardiography (ECG) data for arrhythmia detection was obtained from the MIT-BIH Arrhythmia Database (n=48). A novel feature, namely the heart rate variability calculated from 5s segments of ECG, which was not considered previously, was used. The novel classification approach and feature demonstrated arrhythmia detection accuracy of 89.13%. When the same data was classified using the conventional support vector machine (SVM), the obtained accuracy was 91.69%, 88.14%, and 88.74% for Gaussian, linear, and polynomial kernels, respectively. In terms of computation time, the proposed classifier was 5821.7 times faster than conventional SVM. In conclusion, the proposed classifier and feature showed performance comparable to those of previous studies, while the computational complexity and update interval were highly reduced. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Ventricular Arrhythmias in the North American Multidisciplinary Study of ARVC

    PubMed Central

    Link, Mark S.; Laidlaw, Douglas; Polonsky, Bronislava; Zareba, Wojciech; McNitt, Scott; Gear, Kathleen; Marcus, Frank; Mark Estes, NA

    2015-01-01

    BACKGROUND Arrhythmogenic right ventricular cardiomyopathy (ARVC) is associated with sudden cardiac death. However, the selection of patients for implanted cardioverter-defibrillators (ICDs), as well as programming of the ICD, is unclear. OBJECTIVES The objective of this study was to identify predictors, characteristics, and treatment of ventricular arrhythmias in patients with ARVC. METHODS The Multidisciplinary Study of Right Ventricular Cardiomyopathy established the North American ARVC Registry and enrolled patients with a diagnosis of ARVC. Patients were followed prospectively. RESULTS Of 137 patients enrolled, 108 received ICDs. Forty-eight patients had 502 sustained episodes of ventricular arrhythmias, including 489 that were monomorphic and 13 that were polymorphic. In the patients with ICDs, independent predictors of ventricular arrhythmias in follow-up included spontaneous sustained ventricular arrhythmias before ICD implantation and T-wave inversions inferiorly. The only independent predictor for life-threatening arrhythmias, defined as sustained ventricular tachycardia (VT) ≥240 beats/min or ventricular fibrillation, was a younger age at enrollment. Anti-tachycardia pacing (ATP), independent of the cycle length of the VT, was successful in terminating 92% of VT episodes. CONCLUSIONS In the North American ARVC Registry, the majority of ventricular arrhythmias in follow-up are monomorphic. Risk factors for ventricular arrhythmias were spontaneous ventricular arrhythmias before enrollment and a younger age at ICD implantation. ATP is highly successful in terminating VT, and all ICDs should be programmed for ATP, even for rapid VT. PMID:25011714

  9. Arrhythmia

    MedlinePlus

    ... cardiologists who specialize in arrhythmias. Medical and Family Histories To diagnose an arrhythmia, your doctor may ask ... your doctor will use a procedure called cardiac catheterization (KATH-e-ter-ih-ZA-shun). A thin, ...

  10. Effects of Heterogeneous Diffuse Fibrosis on Arrhythmia Dynamics and Mechanism

    PubMed Central

    Kazbanov, Ivan V.; ten Tusscher, Kirsten H. W. J.; Panfilov, Alexander V.

    2016-01-01

    Myocardial fibrosis is an important risk factor for cardiac arrhythmias. Previous experimental and numerical studies have shown that the texture and spatial distribution of fibrosis may play an important role in arrhythmia onset. Here, we investigate how spatial heterogeneity of fibrosis affects arrhythmia onset using numerical methods. We generate various tissue textures that differ by the mean amount of fibrosis, the degree of heterogeneity and the characteristic size of heterogeneity. We study the onset of arrhythmias using a burst pacing protocol. We confirm that spatial heterogeneity of fibrosis increases the probability of arrhythmia induction. This effect is more pronounced with the increase of both the spatial size and the degree of heterogeneity. The induced arrhythmias have a regular structure with the period being mostly determined by the maximal local fibrosis level. We perform ablations of the induced fibrillatory patterns to classify their type. We show that in fibrotic tissue fibrillation is usually of the mother rotor type but becomes of the multiple wavelet type with increase in tissue size. Overall, we conclude that the most important factor determining the formation and dynamics of arrhythmia in heterogeneous fibrotic tissue is the value of maximal local fibrosis. PMID:26861111

  11. Iron does not cause arrhythmias in the guinea pig model of transfusional iron overload.

    PubMed

    Kaiser, Lana; Davis, John; Patterson, Jon; Boyd, Ryan F; Olivier, N Bari; Bohart, George; Schwartz, Kenneth A

    2007-08-01

    Cardiac events, including heart failure and arrhythmias, are the leading cause of death in patients with beta thalassemia. Although cardiac arrhythmias in humans are believed to result from iron overload, excluding confounding factors in the human population is difficult. The goal of the current study was to determine whether cardiac arrhythmias occurred in the guinea pig model of secondary iron overload. Electrocardiograms were recorded by using surgically implanted telemetry devices in guinea pigs loaded intraperitoneally with iron dextran (test animals) or dextran alone (controls). Loading occurred over approximately 6 wk. Electrocardiograms were recorded for 1 wk prior to loading, throughout loading, and for approximately 4 wk after loading was complete. Cardiac and liver iron concentrations were significantly increased in the iron-loaded animals compared with controls and were in the range of those reported for humans with thalassemia. Arrhythmias were rare in both iron-loaded and control guinea pigs. No life-threatening arrhythmias were detected in either group. These data suggest that iron alone may be insufficient to cause cardiac arrhythmias in the iron-loaded guinea pig model and that arrhythmias detected in human patients with iron overload may be the result of a complex interplay of factors.

  12. The use of external event monitoring (web-loop) in the elucidation of symptoms associated with arrhythmias in a general population

    PubMed Central

    Epifanio, Hindalis Ballesteros; Katz, Marcelo; Borges, Melania Aparecida; Corrêa, Alessandra da Graça; Cintra, Fátima Dumas; Grinberg, Rodrigo Leandro; Ludovice, Ana Cristina Pinotti Pedro; Valdigem, Bruno Pereira; da Silva, Nilton José Carneiro; Fenelon, Guilherme

    2014-01-01

    Objective To correlate arrhythmic symptoms with the presence of significant arrhythmias through the external event monitoring (web-loop). Methods Between January and December 2011, the web-loop was connected to 112 patients (46% of them were women, mean age 52±21 years old). Specific arrhythmic symptoms were defined as palpitations, pre-syncope and syncope observed during the monitoring. Supraventricular tachycardia, atrial flutter or fibrillation, ventricular tachycardia, pauses greater than 2 seconds or advanced atrioventricular block were classified as significant arrhythmia. The association between symptoms and significant arrhythmias were analyzed. Results The web-loop recorded arrhythmic symptoms in 74 (66%) patients. Of these, in only 14 (19%) patients the association between symptoms and significant cardiac arrhythmia was detected. Moreover, significant arrhythmia was found in 11 (9.8%) asymptomatic patients. There was no association between presence of major symptoms and significant cardiac arrhythmia (OR=0.57, CI95%: 0.21-1.57; p=0.23). Conclusion We found no association between major symptoms and significant cardiac arrhythmia in patients submitted to event recorder monitoring. Event loop recorder was useful to elucidate cases of palpitations and syncope in symptomatic patients. PMID:25295448

  13. Critical phase transitions during ablation of atrial fibrillation

    NASA Astrophysics Data System (ADS)

    Iravanian, Shahriar; Langberg, Jonathan J.

    2017-09-01

    Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia with significant morbidity and mortality. Pharmacological agents are not very effective in the management of AF. Therefore, ablation procedures have become the mainstay of AF management. The irregular and seemingly chaotic atrial activity in AF is caused by one or more meandering spiral waves. Previously, we have shown the presence of sudden rhythm organization during ablation of persistent AF. We hypothesize that the observed transitions from a disorganized to an organized rhythm is a critical phase transition. Here, we explore this hypothesis by simulating ablation in an anatomically-correct 3D AF model. In 722 out of 2160 simulated ablation, at least one sudden transition from AF to an organized rhythm (flutter) was noted (33%). They were marked by a sudden decrease in the cycle length entropy and increase in the mean cycle length. At the same time, the number of reentrant wavelets decreased from 2.99 ± 0.06 in AF to 1.76 ± 0.05 during flutter, and the correlation length scale increased from 13.3 ± 1.0 mm to 196.5 ± 86.6 mm (both P < 0.0001). These findings are consistent with the hypothesis that transitions from AF to an anatomical flutter behave as phase transitions in complex non-equilibrium dynamical systems with flutter acting as an absorbing state. Clinically, the facilitation of phase transition should be considered a novel mechanism of ablation and may help to design effective ablation strategies.

  14. [Analysis of the heart sound with arrhythmia based on nonlinear chaos theory].

    PubMed

    Ding, Xiaorong; Guo, Xingming; Zhong, Lisha; Xiao, Shouzhong

    2012-10-01

    In this paper, a new method based on the nonlinear chaos theory was proposed to study the arrhythmia with the combination of the correlation dimension and largest Lyapunov exponent, through computing and analyzing these two parameters of 30 cases normal heart sound and 30 cases with arrhythmia. The results showed that the two parameters of the heart sounds with arrhythmia were higher than those with the normal, and there was significant difference between these two kinds of heart sounds. That is probably due to the irregularity of the arrhythmia which causes the decrease of predictability, and it's more complex than the normal heart sound. Therefore, the correlation dimension and the largest Lyapunov exponent can be used to analyze the arrhythmia and for its feature extraction.

  15. About Arrhythmia

    MedlinePlus

    ... may shut down or be damaged. View an animation of arrhythmia . Types of Arrhythmias Atrial Fibrillation = upper ... learn about: S tructure of the heart Watch an animation of heart valve anatomy The heart: four chambers, ...

  16. The Effectiveness of Remote Facilitation in Simulation-Based Pediatric Resuscitation Training for Medical Students.

    PubMed

    Ohta, Kunio; Kurosawa, Hiroshi; Shiima, Yuko; Ikeyama, Takanari; Scott, James; Hayes, Scott; Gould, Michael; Buchanan, Newton; Nadkarni, Vinay; Nishisaki, Akira

    2017-08-01

    To assess the effectiveness of pediatric simulation by remote facilitation. We hypothesized that simulation by remote facilitation is more effective compared to simulation by an on-site facilitator. We defined remote facilitation as a facilitator remotely (1) introduces simulation-based learning and simulation environment, (2) runs scenarios, and (3) performs debriefing with an on-site facilitator. A remote simulation program for medical students during pediatric rotation was implemented. Groups were allocated to either remote or on-site facilitation depending on the availability of telemedicine technology. Both groups had identical 1-hour simulation sessions with 2 scenarios and debriefing. Their team performance was assessed with behavioral assessment tool by a trained rater. Perception by students was evaluated with Likert scale (1-7). Fifteen groups with 89 students participated in a simulation by remote facilitation, and 8 groups with 47 students participated in a simulation by on-site facilitation. Participant demographics and previous simulation experience were similar. Both groups improved their performance from first to second scenario: groups by remote simulation (first [8.5 ± 4.2] vs second [13.2 ± 6.2], P = 0.003), and groups by on-site simulation (first [6.9 ± 4.1] vs second [12.4 ± 6.4], P = 0.056). The performance improvement was not significantly different between the 2 groups (P = 0.94). Faculty evaluation by students was equally high in both groups (7 vs 7; P = 0.65). A pediatric acute care simulation by remote facilitation significantly improved students' performance. In this pilot study, remote facilitation seems as effective as a traditional, locally facilitated simulation. The remote simulation can be a strong alternative method, especially where experienced facilitators are limited.

  17. Merits and limitations of the mode switching rate stabilization pacing algorithms in the implantable cardioverter defibrillator.

    PubMed

    Dijkman, B; Wellens, H J

    2001-09-01

    The 7250 Jewel AF Medtronic model of ICD is the first implantable device in which both therapies for atrial arrhythmias and pacing algorithms for atrial arrhythmia prevention are available. Feasibility of that extensive atrial arrhythmia management requires correct and synergic functioning of different algorithms to control arrhythmias. The ability of the new pacing algorithms to stabilize the atrial rate following termination of treated atrial arrhythmias was evaluated in the marker channel registration of 600 spontaneously occurring episodes in 15 patients with the Jewel AF. All patients (55+/-15 years) had structural heart disease and documented atrial and ventricular arrhythmias. Dual chamber rate stabilization pacing was present in 245 (41 %) of episodes following arrhythmia termination and was a part of the mode switching operation during which pacing was provided in the dynamic DDI mode. This algorithm could function as the atrial rate stabilization pacing only when there was a slow spontaneous atrial rhythm or in presence of atrial premature beats conducted to the ventricles with a normal AV time. In case of atrial premature beats with delayed or absent conduction to the ventricles and in case of ventricular premature beats, the algorithm stabilized the ventricular rate. The rate stabilization pacing in DDI mode during sinus rhythm following atrial arrhythmia termination was often extended in time due to the device-based definition of arrhythmia termination. This was also the case in patients, in whom the DDD mode with true atrial rate stabilization algorithm was programmed. The rate stabilization algorithms in the Jewel AF applied after atrial arrhythmia termination provide pacing that is not based on the timing of atrial events. Only under certain circumstances the algorithm can function as atrial rate stabilization pacing. Adjustments in availability and functioning of the rate stabilization algorithms might be of benefit for the clinical performance of pacing as part of device therapy for atrial arrhythmias.

  18. Recommendations regarding dietary intake and caffeine and alcohol consumption in patients with cardiac arrhythmias: what do you tell your patients to do or not to do?

    PubMed

    Glatter, Kathryn A; Myers, Richard; Chiamvimonvat, Nipavan

    2012-10-01

    The etiology of arrhythmias including atrial fibrillation is multifactorial. Most arrhythmias are associated with comorbid illnesses like hypertension, diabetes, thyroid disease, or advanced age. Although it is tempting to blame a stimulant like caffeine as a trigger for arrhythmias, the literature does not support this idea. There is no real benefit to having patients with arrhythmias limit their caffeine intake. Caffeine is a vasoactive substance that also may promote the release of norepinephrine and epinephrine. However, acute ingestion of caffeine (as coffee or tea) does not cause atrial fibrillation. Even patients suffering a myocardial infarction do not have an increased incidence of ventricular or other arrhythmias after ingesting several cups of coffee. Large epidemiologic studies have also failed to find a connection between the amount of coffee/caffeine used and the development of arrhythmias. As such, it does not make sense to suggest that patients with palpitations, paroxysmal atrial fibrillation, or supraventricular tachycardia, abstain from caffeine use. Energy drinks are a new phenomenon on the beverage market, with 30-50 % of young adults and teens using them regularly. Energy drinks are loaded with caffeine, sugar, and other chemicals that can stimulate the cardiac system. There is an increasing body of mainly anecdotal case reports describing arrhythmias or even sudden death triggered by exercise plus using energy drinks. Clearly, there must be more study in this area, but it is wise to either limit or avoid their use in patients with arrhythmias. Moderate to heavy alcohol use seems to be associated with the development of atrial fibrillation. The term "holiday heart" was coined back in 1978, to describe patients who had atrial fibrillation following binge alcohol use. Thus, it is reasonable to recommend to patients with arrhythmias that they limit their alcohol use, although unfortunately this treatment will likely not completely resolve their arrhythmia.

  19. Low frequency of cardniac arrhythmias and lack of structural heart disease in medically-naïve acromegaly patients: a prospective study at baseline and after 1 year of somatostatin analogs treatment.

    PubMed

    Warszawski, Leila; Kasuki, Leandro; Sá, Rodrigo; Dos Santos Silva, Cintia Marques; Volschan, Isabela; Gottlieb, Ilan; Pedrosa, Roberto Coury; Gadelha, Mônica R

    2016-12-01

    The incidence of arrhythmias may be increased in acromegaly, but the pathophysiologic mechanisms involved are still unclear, and it has never been correlated with structural heart changes analyzed by the gold-standard method cardiac magnetic resonance (CMR). Evaluate the frequency of arrhythmias in drug-naïve acromegaly patients at baseline and after 1 year of somatostatin analogs (SA) treatment and to correlate the occurrence of arrhythmias with the presence of structural heart changes. Consecutive drug-naïve acromegaly patients were recruited. The occurrence of arrhythmias and structural heart changes were studied through 24-h Holter and CMR, respectively, at baseline and after 1-year SA treatment. Thirty-six patients were studied at baseline and 28 were re-evaluated after 1 year of SA treatment. There were 13 females and median age was 48 years (20-73 years). Nine patients (32 %) were controlled after treatment. No sustained arrhythmias were reported in the 24-h Holter. No arrhythmia-related symptoms were observed. Only two patients presented left ventricular hypertrophy and three patients presented fibrosis at baseline. There was no correlation of the left ventricular mass with the number of episodes of arrhythmias and they were not more prevalent in the patients presenting cardiac fibrosis. We found no sustained arrhythmias and a lack of arrhythmia-related symptoms at baseline and after 1 year of SA treatment in a contemporary cohort of acromegaly patients that also present a low frequency of structural heart changes, indicating that these patients may have a lower frequency of heart disease than previously reported.

  20. Living on a knife edge-the daily struggle of coping with symptomatic cardiac arrhythmias.

    PubMed

    Withers, Kathleen L; Wood, Kathryn A; Carolan-Rees, Grace; Patrick, Hannah; Lencioni, Mauro; Griffith, Michael

    2015-06-24

    In 2010 a retrospective audit was undertaken to assess the viability of using PROMs in patients with symptomatic cardiac arrhythmias having undergone percutaneous arrhythmia ablation. A response rate of 74 % was achieved, with finding suggesting that arrhythmia patients reported a significant impact on their work, social and family life. To conduct a qualitative cross sectional survey to understand patients' perspectives of how cardiac arrhythmias affect their daily lives, as part of a program to develop a Patient Reported Outcome Measure (PROM). Twenty five patients aged 18 or over, diagnosed with a variety of symptomatic cardiac arrhythmias referred for a cardiac ablation procedure took part in cognitive interviews. These aimed to inform the development of a patient reported outcome measure and to determine factors important to this patient group. Common themes were identified using content analysis. Participants reported that symptoms of their arrhythmia caused them considerable problems and impacted adversely on their quality of life in many ways. This extended through daily routine, work and social activities and also to friends and family, with fear and anxiety being significant factors for most responders. Patients felt their illness was poorly understood, even by health professionals, and often reported that they felt isolated, lacking support and information. Symptomatic cardiac arrhythmias are a source of debilitating and life limiting symptoms, having a negative impact on quality of life. Symptoms and related complications are relevant across different arrhythmia substrates and patient groups. The study is registered on the Clinical Trials website, Identifier NCT01672528.

  1. Arrhythmias Following Comprehensive Stage II Surgical Palliation in Single Ventricle Patients.

    PubMed

    Wilhelm, Carolyn M; Paulus, Diane; Cua, Clifford L; Kertesz, Naomi J; Cheatham, John P; Galantowicz, Mark; Fernandez, Richard P

    2016-03-01

    Post-operative arrhythmias are common in pediatric patients following cardiac surgery. Following hybrid palliation in single ventricle patients, a comprehensive stage II palliation is performed. The incidence of arrhythmias in patients following comprehensive stage II palliation is unknown. The purpose of this study is to determine the incidence of arrhythmias following comprehensive stage II palliation. A single-center retrospective chart review was performed on all single ventricle patients undergoing a comprehensive stage II palliation from January 2010 to May 2014. Pre-operative, operative, and post-operative data were collected. A clinically significant arrhythmia was defined as an arrhythmia which led to cardiopulmonary resuscitation or required treatment with either pacing or antiarrhythmic medication. Statistical analysis was performed with Wilcoxon rank-sum test and Fisher's exact test with p < 0.05 significant. Forty-eight single ventricle patients were reviewed (32 hypoplastic left heart syndrome, 16 other single ventricle variants). Age at surgery was 185 ± 56 days. Cardiopulmonary bypass time was 259 ± 45 min. Average vasoactive-inotropic score was 5.97 ± 7.58. Six patients (12.5 %) had clinically significant arrhythmias: four sinus bradycardia, one 2:1 atrioventricular block, and one slow junctional rhythm. No tachyarrhythmias were documented for this patient population. Presence of arrhythmia was associated with elevated lactate (p = 0.04) and cardiac arrest (p = 0.002). Following comprehensive stage II palliation, single ventricle patients are at low risk for development of tachyarrhythmias. The most frequent arrhythmia seen in these patients was sinus bradycardia associated with respiratory compromise.

  2. Arrhythmias in left ventricular noncompaction.

    PubMed

    Miyake, Christina Y; Kim, Jeffrey J

    2015-06-01

    Left ventricular noncompaction (LVNC) is a newly recognized form of cardiomyopathy that has been associated with heart failure, arrhythmias, thromboembolic events, and sudden death. Both ventricular and supraventricular arrhythmias are now well described as prominent clinical components of LVNC. Throughout the spectrum of age, these arrhythmias have been associated with prognosis and outcome, and their clinical management is therefore an important aspect of patient care. The risk of sudden death seems to be associated with ventricular dilation, systolic dysfunction, and the presence of arrhythmias. Proposed management strategies shown to have efficacy include antiarrhythmic therapy, ablation techniques, and implantable cardioverter-defibrillator implantation. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. [Predictors of cardiac arrhythmias in patients with arterial hypertension during exercise stress testing].

    PubMed

    Kolesnik, M Iu; Sokolova, M V

    2014-02-01

    Arterial hypertension is an important risk factor for atrial and ventricular arrhythmias. 203 male patients were examined in order to identify predictors of cardiac arrhythmias in patients with arterial hypertension during exercise stress testing. All participants were studied by 24-hour ambulatory blood pressure monitoring, transthoracic echocardiography, an ultrasound scan of the carotid arteries and treadmill test. 47,3% of patients presented cardiac arrhythmias during exercise stress testing. The left ventricular mass, diastolic function and carotid intima-media thickness were found to be independent predictors of exercise-induced arrhythmias. The use of the exercise stress testing may be reasonable for additional risk stratification in hypertensive patients.

  4. Sports and arrhythmias: a report of the International Workshop Venice Arrhythmias 2009.

    PubMed

    Giada, Franco; Biffi, Alessandro; Cannom, David S; Cappato, Riccardo; Capucci, Alessandro; Corrado, Domenico; Delise, Pietro; Drezner, Jonathan A; El-Sherif, Nabil; Estes, Mark; Furlanello, Francesco; Heidbuchel, Hein; Inama, Giuseppe; Lindsay, Bruce D; Maron, Barry J; Maron, Martin S; Mont, Luis; Olshansky, Brian; Pelliccia, Antonio; Thiene, Gaetano; Viskin, Sami; Zeppilli, Paolo; Natale, Andrea; Raviele, Antonio

    2010-10-01

    This article is a report of an international symposium, endorsed by the Section on Sports Cardiology of the European Association for Cardiovascular Prevention and Rehabilitation, the Italian Society of Sports Cardiology, and the Italian Federation of Sports Medicine, which was held within the 11th International Workshop on Cardiac Arrhythmias (Venice Arrhythmias 2009, Venice, Italy, October 2009). The following main topics were discussed during the symposium: the role of novel diagnostic examinations to assess the risk of sudden death in athletes, controversies on arrhythmic risk evaluation in athletes, controversies on the relationship between sports and arrhythmias, and controversies on antiarrhythmic treatment in athletes.

  5. Effect of different doses of oxytocin on cardiac electrophysiology and arrhythmias induced by ischemia.

    PubMed

    Houshmand, Fariba; Faghihi, Mahdieh; Imani, Alireza; Kheiri, Soleiman

    2017-01-01

    The onset of acute myocardial ischemia (MI) is accompanied by a rapid increase in electrical instability and often fatal ventricular arrhythmias. This study investigated that whether oxytocin (OT) can modulate ischemia-induced arrhythmias and considered relationships between the severity of arrhythmia and the electrocardiogram parameters during ischemia. OT (0.0001-1 μg) was administrated intraperitoneally 30 min before ischemia. To examine receptor involved, a selective OT-receptor antagonist, atosiban (ATO), was infused 10 min before OT. OT caused a significant and biphasic dose-dependent reduction in ectopic heart activity and arrhythmia score. OT doses that reduced ventricular arrhythmia elicited significant increase in QT interval. OT attenuated the electrophysiological changes associated with MI and there was significant direct relationship between QRS duration and arrhythmia score. ATO treatment reduced beneficial effects of OT on arrhythmogenesis. Nevertheless, ATO failed to alter OT effects on premature ventricular contractions. We assume that the ability of OT to modulate the electrical activity of the heart may play an important role in the antiarrhythmic actions of OT.

  6. Effect of different doses of oxytocin on cardiac electrophysiology and arrhythmias induced by ischemia

    PubMed Central

    Houshmand, Fariba; Faghihi, Mahdieh; Imani, Alireza; Kheiri, Soleiman

    2017-01-01

    The onset of acute myocardial ischemia (MI) is accompanied by a rapid increase in electrical instability and often fatal ventricular arrhythmias. This study investigated that whether oxytocin (OT) can modulate ischemia-induced arrhythmias and considered relationships between the severity of arrhythmia and the electrocardiogram parameters during ischemia. OT (0.0001–1 μg) was administrated intraperitoneally 30 min before ischemia. To examine receptor involved, a selective OT-receptor antagonist, atosiban (ATO), was infused 10 min before OT. OT caused a significant and biphasic dose-dependent reduction in ectopic heart activity and arrhythmia score. OT doses that reduced ventricular arrhythmia elicited significant increase in QT interval. OT attenuated the electrophysiological changes associated with MI and there was significant direct relationship between QRS duration and arrhythmia score. ATO treatment reduced beneficial effects of OT on arrhythmogenesis. Nevertheless, ATO failed to alter OT effects on premature ventricular contractions. We assume that the ability of OT to modulate the electrical activity of the heart may play an important role in the antiarrhythmic actions of OT. PMID:29184844

  7. Phase synchrony reveals organization in human atrial fibrillation

    PubMed Central

    Vidmar, David; Narayan, Sanjiv M.

    2015-01-01

    It remains unclear if human atrial fibrillation (AF) is spatially nonhierarchical or exhibits a hierarchy of organization sustained by sources. We utilize activation times obtained at discrete locations during AF to compute the phase synchrony between tissue regions, to examine underlying spatial dynamics throughout both atria. We construct a binary synchronization network and show that this network can accurately define regions of coherence in coarse-grained in silico data. Specifically, domains controlled by spiral waves exhibit regions of high phase synchrony. We then apply this analysis to clinical data from patients experiencing cardiac arrhythmias using multielectrode catheters to simultaneously record from a majority of both atria. We show that pharmaceutical intervention with ibutilide organizes activation by increasing the size of the synchronized domain in AF and quantify the increase in temporal organization when arrhythmia changes from fibrillation to tachycardia. Finally, in recordings from 24 patients in AF we show that the level of synchrony is spatially broad with some patients showing large spatially contiguous regions of synchronization, while in others synchrony is localized to small pockets. Using computer simulations, we show that this distribution is inconsistent with distributions obtained from simulations that mimic multiwavelet reentry but is consistent with mechanisms in which one or more spatially conserved spiral waves is surrounded by tissue in which activation is disorganized. PMID:26475585

  8. Cardiac Arrhythmia and Injury Induced in Rats by Burst and Pulsed Mode Ultrasound with Gas Body Contrast Agent

    PubMed Central

    Miller, Douglas L.; Dou, Chunyan; Lucchesi, Benedict R.

    2009-01-01

    Objective Premature complexes (PCs) in the electrocardiogram (ECG) signal have been reported for myocardial contrast echocardiography and also for burst mode (physical therapy) ultrasound with gas body contrast agent at lower peak rarefactional pressure amplitudes (PRPAs). For contrast echocardiography, irreversibly injured cardiomyocytes have been associated with the arrhythmia. The objective was to determine if cardiomyocyte injury is associated with the PCs induced by the burst mode at lower PRPAs. Methods Anesthetized rats were exposed to focused 1.5 MHz ultrasound in a water bath. Evans blue dye was injected IP to stain injured cardiomyocytes and Definity ultrasound contrast agent was infused IV. Continuous burst mode simulated physical therapy ultrasound. Intermittent 2 ms bursts, or envelopes of pulses simulating diagnostic ultrasound, were triggered 1:4 at end systole. PCs were observed on ECG recordings and stained cardiomyocytes were counted in frozen sections. Results The continuous burst mode produced variable PCs and stained cells above 0.3 MPa PRPA. The triggered bursts above 0.3 MPa and pulse envelopes above 1.2 MPa produced statistically significant (P<0.01) PCs and stained cardiomyocytes. Conclusion Irreversible cardiomyocyte injury was associated with the development of PCs for burst mode and occurred at substantially lower PRPAs than for pulsed ultrasound. PMID:19854967

  9. Burden of arrhythmia in recreational marijuana users.

    PubMed

    Desai, Rupak; Patel, Upenkumar; Deshmukh, Abhishek; Sachdeva, Rajesh; Kumar, Gautam

    2018-08-01

    Marijuana or Cannabis is extensively used as a recreational substance globally. Case reports have reported cardiac arrhythmias immediately following recreational marijuana use. However, the burden of arrhythmias in hospitalized marijuana users have not been evaluated through prospective or cross-sectional studies. Therefore, we planned to measure temporal trends of the frequency of arrhythmias in hospitalized marijuana users using National Inpatient Sample (NIS) database in the United States. Copyright © 2018 Elsevier B.V. All rights reserved.

  10. A Novel Automatic Detection System for ECG Arrhythmias Using Maximum Margin Clustering with Immune Evolutionary Algorithm

    PubMed Central

    Zhu, Bohui; Ding, Yongsheng; Hao, Kuangrong

    2013-01-01

    This paper presents a novel maximum margin clustering method with immune evolution (IEMMC) for automatic diagnosis of electrocardiogram (ECG) arrhythmias. This diagnostic system consists of signal processing, feature extraction, and the IEMMC algorithm for clustering of ECG arrhythmias. First, raw ECG signal is processed by an adaptive ECG filter based on wavelet transforms, and waveform of the ECG signal is detected; then, features are extracted from ECG signal to cluster different types of arrhythmias by the IEMMC algorithm. Three types of performance evaluation indicators are used to assess the effect of the IEMMC method for ECG arrhythmias, such as sensitivity, specificity, and accuracy. Compared with K-means and iterSVR algorithms, the IEMMC algorithm reflects better performance not only in clustering result but also in terms of global search ability and convergence ability, which proves its effectiveness for the detection of ECG arrhythmias. PMID:23690875

  11. The Renin-Angiotensin-Aldosterone System (RAAS) and Cardiac Arrhythmias

    PubMed Central

    Iravanian, Shahriar; Dudley, Samuel C.

    2008-01-01

    The role of the renin-angiotensin-aldosterone system (RAAS) in many cardiovascular disorders, including hypertension, cardiac hypertrophy, and atherosclerosis is well established, whereas its relationship with cardiac arrhythmias is a new area of investigation. Atrial fibrillation and malignant ventricular tachyarrhythmias, especially in the setting of cardiac hypertrophy or failure, appear to be examples of RAAS-related arrhythmias, since treatment with RAAS modulators, including angiotensin converting enzyme inhibitors, angiotensin receptor blockers and mineralocorticoid receptor blockers, reduces the incidence of these arrhythmias. RAAS has a multitude of electrophysiological effects and can potentially cause arrhythmia through a variety of mechanisms. We review new experimental results that suggest RAAS has pro-arrhythmic effects on membrane and sarcoplasmic reticulum ion channels and that increased oxidative stress is likely contributing to the increased arrhythmic incidence. A summary of ongoing clinical trials that will address the clinical usefulness of RAAS modulators for prevention or treatment of arrhythmias is presented. PMID:18456194

  12. The renin-angiotensin-aldosterone system (RAAS) and cardiac arrhythmias.

    PubMed

    Iravanian, Shahriar; Dudley, Samuel C

    2008-06-01

    The role of the renin-angiotensin-aldosterone system (RAAS) in many cardiovascular disorders, including hypertension, cardiac hypertrophy, and atherosclerosis, is well established, whereas its relationship with cardiac arrhythmias is a new area of investigation. Atrial fibrillation and malignant ventricular tachyarrhythmias, especially in the setting of cardiac hypertrophy or failure, seem to be examples of RAAS-related arrhythmias because treatment with RAAS modulators, including angiotensin-converting enzyme inhibitors, angiotensin receptor blockers, and mineralocorticoid receptor blockers, reduces the incidence of these arrhythmias. RAAS has a multitude of electrophysiological effects and can potentially cause arrhythmia through a variety of mechanisms. We review new experimental results that suggest that RAAS has proarrhythmic effects on membrane and sarcoplasmic reticulum ion channels and that increased oxidative stress is likely contributing to the increased arrhythmic incidence. A summary of ongoing clinical trials that will address the clinical usefulness of RAAS modulators for prevention or treatment of arrhythmias is presented.

  13. Conventional versus 3-D Echocardiography to Predict Arrhythmia Recurrence After Atrial Fibrillation Ablation.

    PubMed

    Bossard, Matthias; Knecht, Sven; Aeschbacher, Stefanie; Buechel, Ronny R; Hochgruber, Thomas; Zimmermann, Andreas J; Kessel-Schaefer, Arnheid; Stephan, Frank-Peter; Völlmin, Gian; Pradella, Maurice; Sticherling, Christian; Osswald, Stefan; Kaufmann, Beat A; Conen, David; Kühne, Michael

    2017-06-01

    Arrhythmia recurrence after atrial fibrillation (AF) ablation remains high and requires repeat interventions in a substantial number of patients. We assessed the value of conventional and 3-D echocardiography to predict AF recurrence. Consecutive patients undergoing AF ablation by means of pulmonary vein isolation were included in a prospective registry. Echocardiograms were obtained prior to the ablation procedure, and analyzed offline in a standardized manner, including 3-D left atrial (LA) volumetry and determination of LA function and sphericity. The primary endpoint, AF recurrence (>30 seconds) between 3 to 12 months after AF ablation, was independently adjudicated. We included 276 patients (73% male, mean age 59.9 ± 9.9 years). Paroxysmal and persistent AF were present in 178 (64%) and 98 (36%) patients, respectively. Mean left ventricular ejection fraction and indexed LA volume in 3-D (LAVI) were 52 ± 12% and 42 ± 13 mL/m 2 , respectively. AF recurrence was observed in 110 (40%) patients after a single procedure. Median (interquartile range) time to AF recurrence was 123 (92; 236) days. In multivariable Cox regression models, the only predictors for AF recurrence were the minimal, maximal, and indexed 3-D LA volumes, P = 0.024, P = 0.016, and P = 0.014, respectively. Quartile specific analysis of 3-D LAVI showed an HR of 1.885 (95%CI 1.066-3.334; P for trend = 0.015) for the highest compared to the lowest quartile. Our results show the important role of LA volume for the long-term freedom from arrhythmia after AF ablation. These data also highlight the potential of 3-D echocardiography in this context and may facilitate patient selection for AF ablation. © 2017 Wiley Periodicals, Inc.

  14. Advanced ECG in 2016: is there more than just a tracing?

    PubMed

    Reichlin, Tobias; Abächerli, Roger; Twerenbold, Raphael; Kühne, Michael; Schaer, Beat; Müller, Christian; Sticherling, Christian; Osswald, Stefan

    2016-01-01

    The 12-lead electrocardiogram (ECG) is the most frequently used technology in clinical cardiology. It is critical for evidence-based management of patients with most cardiovascular conditions, including patients with acute myocardial infarction, suspected chronic cardiac ischaemia, cardiac arrhythmias, heart failure and implantable cardiac devices. In contrast to many other techniques in cardiology, the ECG is simple, small, mobile, universally available and cheap, and therefore particularly attractive. Standard ECG interpretation mainly relies on direct visual assessment. The progress in biomedical computing and signal processing, and the available computational power offer fascinating new options for ECG analysis relevant to all fields of cardiology. Several digital ECG markers and advanced ECG technologies have shown promise in preliminary studies. This article reviews promising novel surface ECG technologies in three different fields. (1) For the detection of myocardial ischaemia and infarction, QRS morphology feature analysis, the analysis of high frequency QRS components (HF-QRS) and methods using vectorcardiography as well as ECG imaging are discussed. (2) For the identification and management of patients with cardiac arrhythmias, methods of advanced P-wave analysis are discussed and the concept of ECG imaging for noninvasive localisation of cardiac arrhythmias is presented. (3) For risk stratification of sudden cardiac death and the selection of patients for medical device therapy, several novel markers including an automated QRS-score for scar quantification, the QRS-T angle or the T-wave peak-to-end-interval are discussed. Despite the existing preliminary data, none of the advanced ECG markers and technologies has yet accomplished the transition into clinical practice. Further refinement of these technologies and broader validation in large unselected patient cohorts are the critical next step needed to facilitate translation of advanced ECG technologies into clinical cardiology.

  15. Effect of magnesium on arrhythmia incidence in patients undergoing coronary artery bypass grafting.

    PubMed

    Mohammadzadeh, Alireza; Towfighi, Farshad; Jafari, Naser

    2018-06-01

    Cardiac arrhythmia after coronary artery bypass grafting (CABG) surgery is a common complication of cardiac surgery. The effect of serum magnesium, hypomagnesaemia treatment and prophylactic administration of magnesium in the development and prevention of arrhythmias is controversial and there are many different ideas. This study evaluates the therapeutic effects of magnesium in cardiac arrhythmia after CABG surgery. The clinical trial enrolled 250 patients who underwent CABG. Based on the initial serum levels of magnesium, patients were divided into two groups: hypomagnesium and normomagnesium. Based on bioethics committee requirements, patients in the hypo-magnesium group received magnesium treatments until they attained normal magnesium blood levels. Both groups underwent CABG with normal blood levels of magnesium. After surgery, each group was randomly divided into two subgroups: one subgroup received a bolus dose of magnesium sulphate (30 mg/kg in 5 min) and the other subgroup received a placebo. Subgroups were under observation in the intensive care unit for 3 days and arrhythmias were recorded. Data from all four subgroups were analysed statistically and interpreted. The results of this study showed that the occurrence of arrhythmia was not significantly different among subgroups (P > 0.05). There was no significant relationship between blood levels of magnesium and arrhythmia during the 3 days post-surgery (P > 0.05). The results of this study showed that magnesium sulphate administration did not significantly improve the incidence of arrhythmias in hypo- and normo-magnesium patients after CABG. There was no significant correlation between post-operative serum levels of magnesium and arrhythmia during 3 days. © 2017 Royal Australasian College of Surgeons.

  16. Inhibition of Angiotensin-II Production Increases Susceptibility to Acute Ischemia/Reperfusion Arrhythmia

    PubMed Central

    Taskin, Eylem; Tuncer, Kadir Ali; Guven, Celal; Kaya, Salih Tunc; Dursun, Nurcan

    2016-01-01

    Background Myocardial ischemia and reperfusion lead to impairment of electrolyte balance and, eventually, lethal arrhythmias. The aim of this study was to investigate the effects of pharmacological inhibition of angiotensin-II (Ang-II) production on heart tissue with ischemia-reperfusion damage, arrhythmia, and oxidative stress. Material/Methods Rats were divided into 4 groups: only ischemia/reperfusion (MI/R), captopril (CAP), aliskiren (AL), and CAP+AL. The drugs were given by gavage 30 min before anesthesia. Blood pressure and electrocardiography (ECG) were recorded during MI/R procedures. The heart tissue and plasma was kept so as to evaluate the total oxidant (TOS), antioxidant status (TAS), and creatine kinase-MB (CK-MB). Results Creatine kinase-MB was not different among the groups. Although TAS was not affected by inhibition of Ang-II production, TOS was significantly lower in the CAP and/or AL groups than in the MI/R group. Furthermore, oxidative stress index was significantly attenuated in the CAP and/or AL groups. Captopril significantly increased the duration of VT during ischemia; however, it did not have any effect on the incidence of arrhythmias. During reperfusion periods, aliskiren and its combinations with captopril significantly reduced the incidence of other types of arrhythmias. Captopril alone had no effect on the incidence of arrhythmias, but significantly increased arrhythmias score and durations of arrhythmias during reperfusion. MAP and heart rate did not show changes in any groups during ischemic and reperfusion periods. Conclusions Angiotensin-II production appears to be associated with elevated levels of reactive oxygen species, but Ang-II inhibitions increases arrhythmia, mainly by initiating ventricular ectopic beats. PMID:27889788

  17. Sudden cardiac death secondary to antidepressant and antipsychotic drugs

    PubMed Central

    Sicouri, Serge; Antzelevitch, Charles

    2008-01-01

    A number of antipsychotic and antidepressant drugs are known to increase the risk of ventricular arrhythmias and sudden cardiac death. Based largely on a concern over QT prolongation and the development of life-threatening arrhythmias, a number of antipsychotic drugs have been temporarily or permanently withdrawn from the market or their use restricted. Some antidepressants and antipsychotics have been linked to QT prolongation and the development of Torsade de pointes arrhythmias, whereas others have been associated with a Brugada syndrome phenotype and the development of polymorphic ventricular arrhythmias. This review examines the mechanisms and predisposing factors underlying the development of cardiac arrhythmias, and sudden cardiac death, associated with antidepressant and antipsychotic drugs in clinical use. PMID:18324881

  18. Exercising arrhythmias and sudden cardiac death in horses: Review of the literature and comparative aspects.

    PubMed

    Navas de Solis, C

    2016-07-01

    Arrhythmias are common in equine athletes during and immediately after exercise. Many of these rhythm variations are not clinically relevant. In horses, a link between different exercising arrhythmias and poor performance or between exercising arrhythmias and sudden cardiac death (SCD) is strongly suspected but not fully understood or proven. SCD during races or competitions is rare, but has catastrophic consequences for the safety of the human partner and public perceptions of welfare during equestrian sports. This review summarises current knowledge of equine exercise arrhythmias and their implications in SCD and compares existing principles and recommendations for equine subjects with those for human athletes. © 2016 EVJ Ltd.

  19. Cardiac arrhythmias from a malpositioned Greenfield filter in a traumatic quadriplegic.

    PubMed

    Bach, J R; Zaneuski, R; Lee, H

    1990-10-01

    A case study is presented of premature Greenfield filter discharge with intracardiac migration and resulting life-threatening arrhythmias. These arrhythmias also interfered with the patient's transition from ventilatory support via orotracheal intubation to noninvasive positive airway pressure ventilatory support methods. The patient's arrhythmias were controlled by a demand cardiac pacemaker and cardiac glycoside therapy. No anticoagulants were used. She had no further filter migration nor significant complications for 16 months after hospital discharge.

  20. Emotional behavior and arrhythmias induced in cats by hypothalamic stimulation.

    PubMed

    Tashiro, N; Tanaka, T; Fukumoto, T; Hirata, K; Nakao, H

    1985-03-18

    As the relationship between emotional behavior and electrocardiographic (ECG) change induced by hypothalamic stimulation is poorly understood, eighty-four points in various areas within the hypothalamus in conscious cats were stimulated electrically through chronically implanted electrodes, the objective being to clarify the behavior accompanying ECG changes, in particular poststimulus arrhythmias. Forty-one of 84 points elicited behavioral patterns such as defense reaction, pseudo-rage and restlessness (classified as group A), and in twenty-one (51%) of these 41 points arrhythmias occurred after cessation of stimulation. Forty-three of 84 points elicited behavioral patterns including predatory, exploratory and other behavioral responses (classified as group B), and in three (7%) of 43 points, poststimulus arrhythmias followed. Under light anesthesia, stimulations of twofold current intensity were applied at these points, and the incidences of the arrhythmias did not change in either group. The arrhythmia-inducing area in the cases of group A was found to lie dorsal and caudal to the optic chiasma and to extend caudally in the fornix. Three points in the cases of group B were located in the outer area of the aforementioned area. These studies showed that arrhythmias and group A behavior were observed mainly from stimulation of the anterior hypothalamus, whereas stimulation of other areas of the hypothalamus, including the lateral and the posterolateral hypothalamus, produced group B behavior and no arrhythmias.

  1. Exercise capacity and muscle strength and risk of vascular disease and arrhythmia in 1.1 million young Swedish men: cohort study.

    PubMed

    Andersen, Kasper; Rasmussen, Finn; Held, Claes; Neovius, Martin; Tynelius, Per; Sundström, Johan

    2015-09-16

    To investigate the associations of exercise capacity and muscle strength in late adolescence with risk of vascular disease and arrhythmia. Cohort study. General population in Sweden. 1.1 million men who participated in mandatory military conscription between 1 August 1972 and 31 December 1995, at a median age of 18.2 years. Participants were followed until 31 December 2010. Associations between exercise capacity and muscle strength with risk of vascular disease and subgroups (ischaemic heart disease, heart failure, stroke, and cardiovascular death) and risk of arrhythmia and subgroups (atrial fibrillation or flutter, bradyarrhythmia, supraventricular tachycardia, and ventricular arrhythmia or sudden cardiac death). Maximum exercise capacity was estimated by the ergometer bicycle test, and muscle strength was measured as handgrip strength by a hand dynamometer. High exercise capacity or muscle strength was deemed as above the median level. During a median follow-up of 26.3 years, 26 088 vascular disease events and 17 312 arrhythmia events were recorded. Exercise capacity was inversely associated with risk of vascular disease and its subgroups. Muscle strength was also inversely associated with vascular disease risk, driven by associations of higher muscle strength with lower risk of heart failure and cardiovascular death. Exercise capacity had a U shaped association with risk of arrhythmia, driven by a direct association with risk of atrial fibrillation and a U shaped association with bradyarrhythmia. Higher muscle strength was associated with lower risk of arrhythmia (specifically, lower risk of bradyarrhythmia and ventricular arrhythmia). The combination of high exercise capacity and high muscle strength was associated with a hazard ratio of 0.67 (95% confidence interval 0.65 to 0.70) for vascular events and 0.92 (0.88 to 0.97) for arrhythmia compared with the combination of low exercise capacity and low muscle strength. Exercise capacity and muscle strength in late adolescence are independently and jointly associated with long term risk of vascular disease and arrhythmia. The health benefit of lower risk of vascular events with higher exercise capacity was not outweighed by higher risk of arrhythmia. © Andersen et al 2015.

  2. Mechanisms involved in cardiac sensitization by volatile anesthetics: general applicability to halogenated hydrocarbons?

    PubMed

    Himmel, Herbert M

    2008-01-01

    An increased sensitivity of the heart to catecholamines or cardiac sensitization is a recognized risk during acute human exposure to halogenated hydrocarbons used as solvents, foam-blowing or fire-extinguishing agents, refrigerants, and aerosol propellants. Although cardiac sensitization to such "industrial" halocarbons can result in serious arrhythmia and death, research into its mechanistic basis has been limited, whereas the literature on volatile anesthetics (e.g., halothane, chloroform) is comparably extensive. A review of the literature on halocarbons and related volatile anesthetics was conducted. The available experimental evidence suggests that volatile anesthetics at physiologically relevant concentrations interact predominantly with the main repolarizing cardiac potassium channels hERG and I(Ks), as well as with calcium and sodium channels at slightly higher concentrations. On the level of the heart, inhibition of these ion channels is prone to alter both action potential shape (triangulation) and electrical impulse conduction, which may facilitate arrhythmogenesis by volatile anesthetics per se and is potentiated by catecholamines. Action potential triangulation by regionally heterogeneous inhibition of calcium and potassium channels will facilitate catecholamine-induced afterdepolarizations, triggered activity, and enhanced automaticity. Inhibition of cardiac sodium channels will reduce conduction velocity and alter refractory period; this is potentiated by catecholamines and promotes reentry arrhythmias. Other cardiac and/or neuronal mechanisms might also contribute to arrhythmogenesis. The few scattered in vitro data available for halocarbons (e.g., FC-12, halon 1301, trichloroethylene) suggest inhibition of cardiac sodium (conduction), calcium and potassium channels (triangulation), extraneuronal catecholamine reuptake, and various neuronal ion channels. Therefore, it is hypothesized that halocarbons promote cardiac sensitization by similar mechanisms as volatile anesthetics. Experimental approaches for further investigation of these sensitization mechanisms by selected halocarbons are suggested.

  3. Atrial Arrhythmia Summit: Post Summit Report

    NASA Technical Reports Server (NTRS)

    Barr, Yael

    2010-01-01

    The Atrial Arrhythmia Summit brought together nationally and internationally recognized experts in cardiology, electrophysiology, exercise physiology, and space medicine in an effort to elucidate the mechanisms, risk factors, and management of atrial arrhythmias in the unique occupational cohort of the U.S. astronaut corps.

  4. NON-PHARMACOLOGICAL MANAGEMENT OF ATRIAL FIBRILLATION: ROLE OF PULMONARY VEINS AND THE POSTERIOR LEFT ATRIUM

    PubMed Central

    Shivkumar, Kalyanam; Buch, Eric; Boyle, Noel G.

    2009-01-01

    Non pharmacological approaches for the management of atrial fibrillation are rapidly emerging as the mainstay for the definitive management of this arrhythmia. Over the past several years, numerous studies have appeared in the literature that have highlighted various aspects of the pathophysiological mechanisms underlying this arrhythmia. The purpose of this brief review is to place the current apporaches being ulitized for arrhythmia management in context of what is known about arrhythmia mechanisms. PMID:19959144

  5. β1-Adrenoceptor blocker aggravated ventricular arrhythmia.

    PubMed

    Wang, Yan; Patel, Dimpi; Wang, Dao Wu; Yan, Jiang Tao; Hsia, Henry H; Liu, Hao; Zhao, Chun Xia; Zuo, Hou Juan; Wang, Dao Wen

    2013-11-01

    To assess the impact of β1 -adrenoceptor blockers (β1 -blocker) and isoprenaline on the incidence of idiopathic repetitive ventricular arrhythmia that apparently decreases with preprocedural anxiety. From January 2010 to July 2012, six patients were identified who had idiopathic ventricular arrhythmias that apparently decreased (by greater than 90%) with preprocedural anxiety. The number of ectopic ventricular beats per hour (VPH) was calculated from Holter or telemetry monitoring to assess the ectopic burden. The mean VPH of 24 hours from Holter before admission (VPH-m) was used as baseline (100%) for normalization. β1 -Blockers, isoprenaline, and/or aminophylline were administrated successively on the ward and catheter lab to evaluate their effects on the ventricular arrhythmias. Among 97 consecutive patients with idiopathic ventricular arrhythmias, six had reduction in normalized VPHs in the hour before the scheduled procedure time from (104.6 ± 4.6%) to (2.8 ± 1.6%) possibly due to preprocedural anxiety (P < 0.05), then increased to (97.9 ± 9.7%) during β1 -blocker administration (P < 0.05), then quickly reduced to (1.6 ± 1.0%) during subsequent isoprenaline infusion. Repeated β1 -blocker quickly counteracted the inhibitory effect of isoprenaline, and VPHs increased to (120.9 ± 2.4%) from (1.6 ± 1.0%; P < 0.05). Isoprenaline and β1 -blocker showed similar effects on the arrhythmias in catheter lab. In some patients with structurally normal heart and ventricular arrhythmias there is a marked reduction of arrhythmias associated with preprocedural anxiety. These patients exhibit a reproducible sequence of β1 -blocker aggravation and catecholamine inhibition of ventricular arrhythmias, including both repetitive ventricular premature beats and monomorphic ventricular tachycardia. ©2013, The Authors. Journal compilation ©2013 Wiley Periodicals, Inc.

  6. Malignant ventricular arrhythmias in alcoholic cardiomyopathy.

    PubMed

    Guzzo-Merello, Gonzalo; Dominguez, Fernando; González-López, Esther; Cobo-Marcos, Marta; Gomez-Bueno, Manuel; Fernandez-Lozano, Ignacio; Millan, Isabel; Segovia, Javier; Alonso-Pulpon, Luis; Garcia-Pavia, Pablo

    2015-11-15

    Excessive alcohol consumption is a well-known aetiology of atrial arrhythmias but there is little information concerning the prevalence or incidence of malignant ventricular arrhythmias in alcoholic cardiomyopathy (ACM). This study sought to investigate incidence and predictive factors of ventricular arrhythmias in ACM. Retrospective observational study of the clinical characteristics and long-term arrhythmic events in 282 consecutive patients with ACM (94 individuals) and idiopathic dilated cardiomyopathy (IDCM) (188 individuals) evaluated between 1993 and 2011. During a median follow-up of 38months (IQR:12-77), 42 patients died and 79 underwent heart transplantation [31 (33%) with ACM vs 90 (48%) with IDCM; p=0.017]. A total of 37 (13%) patients [18 (19%) ACM vs 20 (11%) IDCM; p=0.048] suffered malignant ventricular arrhythmias. On multivariate analysis, left bundle branch block (LBBB) (OR 2.4; CI95%: 1.2-5; p=0.015) and alcoholic aetiology (OR 2.3; CI95%: 1.1-4.5; p=0.026) were the only independent predictors of malignant ventricular arrhythmic events. A total of 18 (19%) ACM patients experienced 20 malignant ventricular arrhythmic events (4 aborted SCD, 8 SCD and 8 appropriate ICD therapies). At baseline evaluation, the only independent predictor of malignant ventricular arrhythmias in ACM patients was LBBB (OR 11.2; CI95%: 2.6-50; p=0.001). No malignant ventricular arrhythmias were recorded during follow-up in ACM patients if left ventricular ejection fraction (LVEF) had increased or remained ≥40%. Malignant ventricular arrhythmias are more frequent in ACM than in IDCM. LBBB identifies ACM patients with increased risk of SCD. No malignant ventricular arrhythmias were found during follow-up in ACM patients when LVEF was ≥40%. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  7. Interactions between pacing and arrhythmia detection algorithms in the dual chamber implantable cardioverter defibrillator.

    PubMed

    Dijkman, B; Wellens, H J

    2001-09-01

    Dual chamber implantable cardioverter defibrillator (ICD) combines the possibility to detect and treat ventricular and atrial arrhythmias with the possibility of modern heart stimulation techniques. Advanced pacing algorithms together with extended arrhythmia detection capabilities can give rise to new types of device-device interactions. Some of the possible interactions are illustrated by four cases documented in four models of dual chamber ICDs. Functioning of new features in dual chamber devices is influenced by the fact that the pacemaker is not a separate device but a part of the ICD system and that both are being used in a patient with arrhythmia. Programming measures are suggested to optimize use of new pacing algorithms while maintaining correct arrhythmia detection.

  8. Antiarrhythmic activity of n-tyrosol during acute myocardial ischemia and reperfusion.

    PubMed

    Chernyshova, G A; Plotnikov, M B; Smol'yakova, V I; Golubeva, I V; Aliev, O I; Tolstikova, T G; Krysin, A P; Sorokina, I V

    2007-06-01

    Antiarrhythmic activity of n-tyrosol was demonstrated on the model of early occlusion and reperfusion arrhythmia. The preparation reduces the incidence of ventricular tachycardia and fibrillation, increases the percent of animals without ventricular arrhythmia, and moderates the severity of developing ventricular arrhythmias.

  9. Cardiorespiratory interactions in patients with atrial flutter.

    PubMed

    Masè, Michela; Disertori, Marcello; Ravelli, Flavia

    2009-01-01

    Respiratory sinus arrhythmia (RSA) is generally known as the autonomically mediated modulation of the sinus node pacemaker frequency in synchrony with respiration. Cardiorespiratory interactions have been largely investigated during sinus rhythm, whereas little is known about interactions during reentrant arrhythmias. In this study, cardiorespiratory interactions at the atrial and ventricular level were investigated during atrial flutter (AFL), a supraventricular arrhythmia based on a reentry, by using cross-spectral analysis and computer modeling. The coherence and phase between respiration and atrial (gamma(AA)(2), phi(AA)) and ventricular (gamma(RR)(2), phi(RR)) interval series were estimated in 20 patients with typical AFL (68.0 +/- 8.8 yr) and some degree of atrioventricular (AV) conduction block. In all patients, atrial intervals displayed oscillations strongly coupled and in phase with respiration (gamma(AA)(2)= 0.97 +/- 0.05, phi(AA) = 0.71 +/- 0.31 rad), corresponding to a paradoxical lengthening of intervals during inspiration. The modulation pattern was frequency independent, with in-phase oscillations and short time delays (0.40 +/- 0.15 s) for respiratory frequencies in the range 0.1-0.4 Hz. Ventricular patterns were affected by AV conduction type. In patients with fixed AV conduction, ventricular intervals displayed oscillations strongly coupled (gamma(RR)(2)= 0.97 +/- 0.03) and in phase with respiration (phi(RR) = 1.08 +/- 0.80 rad). Differently, in patients with variable AV conduction, respiratory oscillations were secondary to Wencheback rhythmicity, resulting in a decreased level of coupling (gamma(RR)(2)= 0.50 +/- 0.21). Simulations with a simplified model of AV conduction showed ventricular patterns to originate from the combination of a respiratory modulated atrial input with the functional properties of the AV node. The paradoxical frequency-independent modulation pattern of atrial interval, the short time delays, and the complexity of ventricular rhythm characterize respiratory arrhythmia during AFL and distinguish it from normal RSA. These peculiar features can be explained by assuming a direct mechanical action of respiration on AFL reentrant circuit.

  10. A Study of Early Afterdepolarizations in a Model for Human Ventricular Tissue

    PubMed Central

    Vandersickel, Nele; Kazbanov, Ivan V.; Nuitermans, Anita; Weise, Louis D.; Pandit, Rahul; Panfilov, Alexander V.

    2014-01-01

    Sudden cardiac death is often caused by cardiac arrhythmias. Recently, special attention has been given to a certain arrhythmogenic condition, the long-QT syndrome, which occurs as a result of genetic mutations or drug toxicity. The underlying mechanisms of arrhythmias, caused by the long-QT syndrome, are not fully understood. However, arrhythmias are often connected to special excitations of cardiac cells, called early afterdepolarizations (EADs), which are depolarizations during the repolarizing phase of the action potential. So far, EADs have been studied mainly in isolated cardiac cells. However, the question on how EADs at the single-cell level can result in fibrillation at the tissue level, especially in human cell models, has not been widely studied yet. In this paper, we study wave patterns that result from single-cell EAD dynamics in a mathematical model for human ventricular cardiac tissue. We induce EADs by modeling experimental conditions which have been shown to evoke EADs at a single-cell level: by an increase of L-type Ca currents and a decrease of the delayed rectifier potassium currents. We show that, at the tissue level and depending on these parameters, three types of abnormal wave patterns emerge. We classify them into two types of spiral fibrillation and one type of oscillatory dynamics. Moreover, we find that the emergent wave patterns can be driven by calcium or sodium currents and we find phase waves in the oscillatory excitation regime. From our simulations we predict that arrhythmias caused by EADs can occur during normal wave propagation and do not require tissue heterogeneities. Experimental verification of our results is possible for experiments at the cell-culture level, where EADs can be induced by an increase of the L-type calcium conductance and by the application of I blockers, and the properties of the emergent patterns can be studied by optical mapping of the voltage and calcium. PMID:24427289

  11. Assessing the Atrial Electromechanical Coupling during Atrial Focal Tachycardia, Flutter, and Fibrillation using Electromechanical Wave Imaging in Humans

    PubMed Central

    Provost, Jean; Costet, Alexandre; Wan, Elaine; Gambhir, Alok; Whang, William; Garan, Hasan; Konofagou, Elisa E.

    2015-01-01

    Minimally-invasive treatments of cardiac arrhythmias such as radio-frequency ablation are gradually gaining in importance in clinical practice but still lack a noninvasive imaging modality which provides insight into the source or focus of an arrhythmia. Cardiac deformations imaged at high temporal and spatial resolution can be used to elucidate the electrical activation sequence in normal and paced human subjects non-invasively and could potentially aid to better plan and monitor ablation-based arrhythmia treatments. In this study, a novel ultrasound-based method is presented that can be used to quantitatively characterize focal and reentrant arrhythmias. Spatio-temporal maps of the full-view of the atrial and ventricular mechanics were obtained in a single heartbeat, revealing with otherwise unobtainable detail the electromechanical patterns of atrial flutter, fibrillation, and tachycardia in humans. During focal arrhythmias such as premature ventricular complex and focal atrial tachycardia, the previously developed electromechanical wave imaging methodology is hereby shown capable of identifying the location of the focal zone and the subsequent propagation of cardiac activation. During reentrant arrhythmias such as atrial flutter and fibrillation, Fourier analysis of the strains revealed highly correlated mechanical and electrical cycle lengths and propagation patterns. High frame rate ultrasound imaging of the heart can be used non-invasively and in real time, to characterize the lesser-known mechanical aspects of atrial and ventricular arrhythmias, also potentially assisting treatment planning for intraoperative and longitudinal monitoring of arrhythmias. PMID:26361338

  12. Management of supraventricular arrhythmias in adults with congenital heart disease.

    PubMed

    Wasmer, Kristina; Eckardt, Lars

    2016-10-15

    Supraventricular arrhythmias are a frequent complication in adults with congenital heart disease (ACHD). The prevalence increases with time since surgery, complexity of the underlying defect, type of repair and older age at surgery. Arrhythmias are the most frequent reason for hospital admission and along with heart failure the leading cause of death. The arrhythmia-associated increase in morbidity and mortality makes their management a key task in patients with ACHD. Intra-atrial re-entry is the most frequent arrhythmia mechanism. Less common arrhythmia mechanisms are supraventricular tachycardias in the presence of an accessory pathway, atrioventricular nodal re-entrant tachycardia or focal tachycardias. Patient management includes stroke prevention, acute termination and prevention of arrhythmia recurrence. Acute treatment depends on patients' symptoms. In cases of haemodynamic instability, immediate cardioversion is warranted. For stable patients, acute treatment includes rate control and termination by antiarrhythmic drugs or electrical cardioversion. Following a symptomatic arrhythmia, catheter ablation or treatment with antiarrhythmic drugs is recommended to prevent recurrences. Advances in mapping and ablation technology are now associated with high success rates of catheter ablation. In patients with a complex substrate recurrence rates of 50% remain high. However, in the presence of side effects and complications associated with long-term antiarrhythmic drug therapy, redo procedures are encouraged by current guidelines. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  13. [Idiopathic ventricular arrhythmia in children. Apropos of 24 cases].

    PubMed

    Coeurderoy, A; Almange, C; Laurent, M; Biron, Y; Leborgne, P

    1985-12-01

    The severity and prognosis of idiopathic ventricular arrhythmias in childhood were studied in 24 patients (12 boys, 12 girls) with an average age of 8 years at the time of diagnosis of the arrhythmia. Investigations included clinical assessment and analysis of basal ECG (morphology of the arrhythmias) and dynamic recordings (Holter and exercise stress testing). The clinical course was followed for an average of 3.8 years. The patients were classified in two groups: monomorphic arrhythmias (Group I) and polymorphic arrhythmias (Group II). Group I was divided into 4 subgroups: isolated ventricular extrasystoles (IA), 11 patients; ventricular extrasystoles with bursts of ventricular tachycardia (IB), 6 patients; sustained ventricular tachycardia without intercritical extrasystoles (IC), 1 patient; accelerated idioventricular rhythm (ID), 2 patients. Subgroups IA, IB and ID were characterised by the absence of symptoms, the disappearance of the arrhythmia on exercise, the decreased efficacy of antiarrhythmic drugs and an excellent prognosis. Therapeutic abstention was the rule in these patients. Patients in Group IC were characterised by the variability of their symptoms, the absence of exercise induced arrhythmias, the need for treatment in most cases and a good long-term prognosis. Group II was divided into 2 subgroups: adrenergic polymorphic ventricular tachycardia (IIA), 2 patients, and non-adrenergic polymorphic ventricular tachycardia (IIB), 2 patients. Patients in Subgroup IIA were characterised by syncope on exercise or emotion, the need for betablocker therapy which considerably improved the patients symptoms but which did not usually prevent sudden death.(ABSTRACT TRUNCATED AT 250 WORDS)

  14. Obstructive sleep apnoea-hypopnoea and arrhythmias: new updates.

    PubMed

    Vizzardi, Enrico; Sciatti, Edoardo; Bonadei, Ivano; D'Aloia, Antonio; Curnis, Antonio; Metra, Marco

    2017-07-01

    Obstructive sleep apnoea-hypopnoea (OSAH) is a prevalent condition characterized by repetitive pharyngeal collapse during sleep, leading to hypoxemia, hypercapnia, and persistent inspiratory efforts against an occluded airway until arousal. Several studies demonstrated that OSAH exerts acute and chronic effects on the cardiovascular system. Thus, although being a respiratory problem, the most important consequences of OSAH are cardiovascular, among which there are arrhythmias. The purpose of this review is to systematically analyse what has been recently published about the relationship between OSAH and every cardiac arrhythmia separately. We searched Pubmed, Scopus, Web of Science and Cochrane Collaboration databases for 'OSAHS arrhythmias', 'OSAH arrhythmias' and 'OSA arrhythmias'. We analyse 1298 articles and meta-analyses, excluding already edited reviews. Arrhythmias, especially of ventricular origin, are frequent in OSAH. Ventricular premature beats, couplets and ventricular tachycardia runs are even more frequent in patients suffering from heart failure. They may be due to left heart remodelling, overwork and ischaemia and can explain at least some sudden deaths occurring between midnight and 6 a.m. Sinus pauses and atrioventricular blocks are increased according to the severity of the disturbance and may be reduced by continuous positive airway pressure therapy, preventing pace-maker implantation. Finally, atrial fibrillation, resistance against antiarrhythmic drugs and recurrences after surgical procedures are strongly related to OSAH. Arrhythmias are frequent in OSAH. Treatment of OSAH may reduce some of them. An implantable cardioverter-defibrillator and continuous positive airway pressure should be considered in some patients.

  15. Aconitine "challenge" test reveals a single whole-body exposure to diesel exhaust increases cardiac arrhythmia risk in hypertensive rats

    EPA Science Inventory

    Epidemiological studies demonstrate a significant association between cardiac electrical dysfunction, arrhythmias and air pollution exposure. Sensitivity to aconitine-induced arrhythmia has been used repeatedly to examine the factors that increase the risk of such cardiac electri...

  16. Association between activities of SOD, MDA and Na+-K+-ATPase in peripheral blood of patients with acute myocardial infarction and the complication of varying degrees of arrhythmia.

    PubMed

    Yin, Yu; Han, Wei; Cao, Ying

    2018-04-24

    To investigate the changes of ambulatory electrocardiography and peripheral blood SOD, MDA and Na+-K+-ATP enzymes in patients of acute myocardial infarction (AMI) complicated with arrhythmia. From January 2012 to March 2015, 135 cases AMI complicated with arrhythmia in our hospital were divided into 2 groups: 70 cases in the AMI uncomplicated with arrhythmia and 65 cases in the AMI complicated with arrhythmia. 62 cases volunteers accepted physical examination in our hospital in the same period were collected as the control group. 24 hour-electrocardiogram detected by ambulatory electrocardiogram (AECG), SOD and MDA in peripheral blood detected by diagnostic reagent kit and Na+-K+-ATP enzymes in peripheral blood detected by malachite green Kit Method phosphate determination method were collected. ROC curve was used to evaluate the prognostic value of SOD, MDA and Na+-K+-ATP enzymes in AMI patients. Compared with the control group, the patients had unusual ambulatory electrocardiography had increased (P <0.05), peripheral blood SOD and Na+-K+-ATP enzymes had decreased, peripheral blood MDA had increased in 2 AMI groups (P <0.05). Compared with AMI uncomplicated with arrhythmia group, the patients had unusual ambulatory electrocardiography had increased (P <0.05), peripheral blood SOD and Na+-K+-ATP enzymes had decreased, peripheral blood MDA had increased in AMI complicated with arrhythmia group (P <0.05). Among 135 cases AMI patients, 120 (88.9%) survived and 15 (11.1%) died, of whom 11 cases were AMI complicated with arrhythmia group, 4 cases were AMI uncomplicated with arrhythmia group. Compared with the AMI uncomplicated with arrhythmia group, the dead patients were more in the AMI complicated with arrhythmia group (c2 = 4.287, P = 0.038). Compared with the survival group, the SOD and Na+-K+-ATP enzymes were significantly lower (P <0.05) and MDA significantly higher (P <0.05) in the death group. The area under the ROC curve of SOD, MDA and Na+-K+-ATP enzymes were 0.958, 0.954 and 0.993 respectively, and the cut-off values were 30.66 ng/ml, 576.70 nmol/ml and 57.42 nmol/mgh, respectively. Ambulatory electrocardiography has a close relationship with the peripheral blood SOD, MDA and Na+-K+-ATP enzymes in AMI patients complicated with arrhythmia, which might predict AMI condition. Copyright © 2018 Hellenic Society of Cardiology. Published by Elsevier B.V. All rights reserved.

  17. Disease management: atrial fibrillation and home monitoring.

    PubMed

    Ricci, Renato Pietro

    2013-06-01

    Device-detected atrial fibrillation (AF) episodes predict poor clinical outcome regardless of symptoms. Potential benefits of remote monitoring are early arrhythmia detection and patient continuous monitoring. Several studies of device remote monitoring consistently demonstrated that AF represents the most common clinical alert and that detailed information on arrhythmia onset, duration, and burden as well as on the ventricular rate may be early available for clinical evaluation. Reaction time to AF alerts was very short in all series involving either pacemakers or defibrillators and action ability of AF alerts was very high. In the Home Guide Registry, in which 1650 patients were enrolled, AF was detected in 16.3% of patients and represented 36% of all cardiovascular events during the follow-up. Timely anticoagulation introduction in asymptomatic patients may impact on the stroke rate. According to the results of repeated Monte Carlo simulations based on a real population of 166 patients, daily monitoring may reduce the 2-year stroke risk by 9-18% with an absolute reduction of 0.2-0.6%, compared with conventional inter-visit intervals of 6-12 months. In the COMPAS trial, the incidence of hospitalizations for atrial arrhythmias and related stroke was significantly higher in the control group than in the remote monitoring group. Major questions will be addressed by the ongoing IMPACT trial in which a remote monitoring guided anticoagulation strategy based on AF detection will be compared with a physician-directed standard strategy. In patients with heart failure, AF early detection combined with other indexes may help prevent hospitalizations.

  18. Structural contributions to fibrillatory rotors in a patient-derived computational model of the atria

    PubMed Central

    Gonzales, Matthew J.; Vincent, Kevin P.; Rappel, Wouter-Jan; Narayan, Sanjiv M.; McCulloch, Andrew D.

    2014-01-01

    Aims The aim of this study was to investigate structural contributions to the maintenance of rotors in human atrial fibrillation (AF) and possible mechanisms of termination. Methods and results A three-dimensional human biatrial finite element model based on patient-derived computed tomography and arrhythmia observed at electrophysiology study was used to study AF. With normal physiological electrical conductivity and effective refractory periods (ERPs), wave break failed to sustain reentrant activity or electrical rotors. With depressed excitability, decreased conduction anisotropy, and shorter ERP characteristic of AF, reentrant rotors were readily maintained. Rotors were transiently or permanently trapped by fibre discontinuities on the lateral wall of the right atrium near the tricuspid valve orifice and adjacent to the crista terminalis, both known sites of right atrial arrhythmias. Modelling inexcitable regions near the rotor tip to simulate fibrosis anchored the rotors, converting the arrhythmia to macro-reentry. Accordingly, increasing the spatial core of inexcitable tissue decreased the frequency of rotation, widened the excitable gap, and enabled an external wave to impinge on the rotor core and displace the source. Conclusion These model findings highlight the importance of structural features in rotor dynamics and suggest that regions of fibrosis may anchor fibrillatory rotors. Increasing extent of fibrosis and scar may eventually convert fibrillation to excitable gap reentry. Such macro-reentry can then be eliminated by extending the obstacle or by external stimuli that penetrate the excitable gap. PMID:25362167

  19. Aconitine Challenge Test Reveals a Single Exposure to Air Pollution Causes Increased Cardiac Arrhythmia Risk in Hypertensive Rats - Abstract

    EPA Science Inventory

    Epidemiological studies demonstrate a significant association between arrhythmias and air pollution exposure. Sensitivity to aconitine-induced arrhythmia has been used repeatedly to examine the factors that increase the risk of such cardiac electrical dysfunction. In this study, ...

  20. Three-dimensional mapping in the electrophysiological laboratory.

    PubMed

    Maury, Philippe; Monteil, Benjamin; Marty, Lilian; Duparc, Alexandre; Mondoly, Pierre; Rollin, Anne

    2018-06-07

    Investigation and catheter ablation of cardiac arrhythmias are currently still based on optimal knowledge of arrhythmia mechanisms in relation to the cardiac anatomy involved, in order to target their crucial components. Currently, most complex arrhythmias are investigated using three-dimensional electroanatomical navigation systems, because these are felt to optimally integrate both the anatomical and electrophysiological features of a given arrhythmia in a given patient. In this article, we review the technical background of available three-dimensional electroanatomical navigation systems, and their potential use in complex ablations. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  1. Predictive use of routine 24-hour electrocardiography in suspected Adams-Stokes syndrome. Comparison with cardiac rhythm during symptoms.

    PubMed Central

    Abdon, N J; Johansson, B W; Lessem, J

    1982-01-01

    Using strictly defined criteria of significant arrhythmias, long term electrocardiographic recording has been evaluated for confirmation of arrhythmias as the cause of cerebral symptoms in 81 patients with suspected Adams-Stokes syndrome. Extension of long term electrocardiographic recording for more than 24 hours gives marginal additional information at a high cost. Among 43 patients monitored until symptoms appeared, non cardiogenic causes were confirmed in 20 of 22 patients because the recording showed normal rhythm during symptoms. Fifteen of 21 patients with a significant arrhythmia during an asymptomatic 24 hour recording later had the same arrhythmia during symptoms. Of 38 patients who failed to develop symptoms, 21 had a significant arrhythmia detectable within 24 hours and 23 when 48 hours of recording were analysed. PMID:7082502

  2. Islands of spatially discordant APD alternans underlie arrhythmogenesis by promoting electrotonic dyssynchrony in models of fibrotic rat ventricular myocardium

    NASA Astrophysics Data System (ADS)

    Majumder, Rupamanjari; Engels, Marc C.; de Vries, Antoine A. F.; Panfilov, Alexander V.; Pijnappels, Daniël A.

    2016-04-01

    Fibrosis and altered gap junctional coupling are key features of ventricular remodelling and are associated with abnormal electrical impulse generation and propagation. Such abnormalities predispose to reentrant electrical activity in the heart. In the absence of tissue heterogeneity, high-frequency impulse generation can also induce dynamic electrical instabilities leading to reentrant arrhythmias. However, because of the complexity and stochastic nature of such arrhythmias, the combined effects of tissue heterogeneity and dynamical instabilities in these arrhythmias have not been explored in detail. Here, arrhythmogenesis was studied using in vitro and in silico monolayer models of neonatal rat ventricular tissue with 30% randomly distributed cardiac myofibroblasts and systematically lowered intercellular coupling achieved in vitro through graded knockdown of connexin43 expression. Arrhythmia incidence and complexity increased with decreasing intercellular coupling efficiency. This coincided with the onset of a specialized type of spatially discordant action potential duration alternans characterized by island-like areas of opposite alternans phase, which positively correlated with the degree of connexinx43 knockdown and arrhythmia complexity. At higher myofibroblast densities, more of these islands were formed and reentrant arrhythmias were more easily induced. This is the first study exploring the combinatorial effects of myocardial fibrosis and dynamic electrical instabilities on reentrant arrhythmia initiation and complexity.

  3. Sympathetic restraint of respiratory sinus arrhythmia: implications for vagal-cardiac tone assessment in humans

    NASA Technical Reports Server (NTRS)

    Taylor, J. A.; Myers, C. W.; Halliwill, J. R.; Seidel, H.; Eckberg, D. L.

    2001-01-01

    Clinicians and experimentalists routinely estimate vagal-cardiac nerve traffic from respiratory sinus arrhythmia. However, evidence suggests that sympathetic mechanisms may also modulate respiratory sinus arrhythmia. Our study examined modulation of respiratory sinus arrhythmia by sympathetic outflow. We measured R-R interval spectral power in 10 volunteers that breathed sequentially at 13 frequencies, from 15 to 3 breaths/min, before and after beta-adrenergic blockade. We fitted changes of respiratory frequency R-R interval spectral power with a damped oscillator model: frequency-dependent oscillations with a resonant frequency, generated by driving forces and modified by damping influences. beta-Adrenergic blockade enhanced respiratory sinus arrhythmia at all frequencies (at some, fourfold). The damped oscillator model fit experimental data well (39 of 40 ramps; r = 0.86 +/- 0.02). beta-Adrenergic blockade increased respiratory sinus arrhythmia by amplifying respiration-related driving forces (P < 0.05), without altering resonant frequency or damping influences. Both spectral power data and the damped oscillator model indicate that cardiac sympathetic outflow markedly reduces heart period oscillations at all frequencies. This challenges the notion that respiratory sinus arrhythmia is mediated simply by vagal-cardiac nerve activity. These results have important implications for clinical and experimental estimation of human vagal cardiac tone.

  4. A New Algorithm to Diagnose Atrial Ectopic Origin from Multi Lead ECG Systems - Insights from 3D Virtual Human Atria and Torso

    PubMed Central

    Alday, Erick A. Perez; Colman, Michael A.; Langley, Philip; Butters, Timothy D.; Higham, Jonathan; Workman, Antony J.; Hancox, Jules C.; Zhang, Henggui

    2015-01-01

    Rapid atrial arrhythmias such as atrial fibrillation (AF) predispose to ventricular arrhythmias, sudden cardiac death and stroke. Identifying the origin of atrial ectopic activity from the electrocardiogram (ECG) can help to diagnose the early onset of AF in a cost-effective manner. The complex and rapid atrial electrical activity during AF makes it difficult to obtain detailed information on atrial activation using the standard 12-lead ECG alone. Compared to conventional 12-lead ECG, more detailed ECG lead configurations may provide further information about spatio-temporal dynamics of the body surface potential (BSP) during atrial excitation. We apply a recently developed 3D human atrial model to simulate electrical activity during normal sinus rhythm and ectopic pacing. The atrial model is placed into a newly developed torso model which considers the presence of the lungs, liver and spinal cord. A boundary element method is used to compute the BSP resulting from atrial excitation. Elements of the torso mesh corresponding to the locations of the placement of the electrodes in the standard 12-lead and a more detailed 64-lead ECG configuration were selected. The ectopic focal activity was simulated at various origins across all the different regions of the atria. Simulated BSP maps during normal atrial excitation (i.e. sinoatrial node excitation) were compared to those observed experimentally (obtained from the 64-lead ECG system), showing a strong agreement between the evolution in time of the simulated and experimental data in the P-wave morphology of the ECG and dipole evolution. An algorithm to obtain the location of the stimulus from a 64-lead ECG system was developed. The algorithm presented had a success rate of 93%, meaning that it correctly identified the origin of atrial focus in 75/80 simulations, and involved a general approach relevant to any multi-lead ECG system. This represents a significant improvement over previously developed algorithms. PMID:25611350

  5. [The telemedical service centre as an essential element of the conceptual approach for telemonitoring of cardiac patients : Requirements on the service, quality, and technical realization of telemonitoring].

    PubMed

    Helms, T M; Müller, A; Perings, C; Köhler, F; Leonhardt, V; Rybak, K; Sack, S; Stockburger, M

    2017-09-01

    Telemonitoring as part of a treatment strategy supports and facilitates the monitoring, disease management and education of patients with heart failure and cardiac arrhythmias. Therefore, telemonitoring affects quality and success of the therapy. Thus, meeting the needs of the patients and of the involved health care professionals is important for the success of the telemonitoring service. Moreover, a high quality of the service has to be ensured. The following article describes several configuration options for telemonitoring services considering technical as well as quality- and service-related aspects.

  6. Twenty-four-hour ambulatory electrocardiography characterization of heart rhythm in Vipera berus-envenomed dogs.

    PubMed

    Vestberg, Anna Rave; Tidholm, Anna; Ljungvall, Ingrid

    2017-05-03

    Vipera berus has a worldwide distribution and causes high morbidity in dogs annually. A complication to envenomation may be cardiac arrhythmias. The purpose of this study was to investigate the prevalence, types, and timing of arrhythmias, using 24-h ambulatory electrocardiography (24-AECG), in dogs bitten by V. berus in the first 24-32 h after envenomation. In addition, this study aimed to investigate if there were differences in selected clinical and hematological- and biochemical variables (including cardiac troponin I) at admission between V. berus-envenomed dogs with and without detected pathologic arrhythmias. Seventeen prospectively recruited client-owned dogs acutely envenomed by V. berus, were therefore examined clinically and echocardiographically, sampled for blood, hospitalized, and monitored by 24-AECG. Clinically significant pathologic arrhythmias in this study were of ventricular origin, such as frequent single ventricular premature contractions (VPCs) and couplets of VPCs, episodes of ventricular tachycardia and idioventricular rhythm, and "R-on-T phenomenon". Variations of these arrhythmias were detected by 24-AECG in eight (47%) of included dogs. No arrhythmias were detected by cardiac auscultation. Twenty-four hours following envenomation, four out of eight dogs experienced decreases (all P < 0.039), and three out of eight dogs experienced increases (all P < 0.034), in arrhythmic episodes. All four dogs bitten on a limb developed pathologic arrhythmias. Otherwise, no significant differences in clinical, hematological or biochemical variables were seen between dogs with pathologic arrhythmias and those without. Forty-seven percent of dogs bitten by V. berus included in this study experienced pathologic arrhythmias of abnormal ventricular depolarization. During the first 24-32 h from the snakebite, some dogs experienced a decrease in arrhythmic episodes and others an increase in arrhythmic episodes. These findings indicate a potential value of repeated or prolonged electrocardiography monitoring of envenomed dogs for identification of which dogs that might benefit the most from prolonged hospitalization for optimal monitoring and treatment of cardiac abnormalities. In the present study, dogs that developed arrhythmias could not be differentiated from dogs that did not based on clinical findings or hematological or biochemical variables obtained at admission.

  7. Asymptomatic Intradialytic Supraventricular Arrhythmias and Adverse Outcomes in Patients on Hemodialysis

    PubMed Central

    Pérez de Prado, Armando; López-Gómez, Juan M.; Quiroga, Borja; Goicoechea, Marian; García-Prieto, Ana; Torres, Esther; Reque, Javier; Luño, José

    2016-01-01

    Background and objectives Supraventricular arrhythmias are associated with high morbidity and mortality. Nevertheless, this condition has received little attention in patients on hemodialysis. The objective of this study was to analyze the incidence of intradialysis supraventricular arrhythmia and its long–term prognostic value. Design, setting, participants, & measurements We designed an observational and prospective study in a cohort of patients on hemodialysis with a 10-year follow-up period. All patients were recruited for study participation and were not recruited for clinical indications. The study population comprised 77 patients (42 men and 35 women; mean age =58±15 years old) with sinus rhythm monitored using a Holter electrocardiogram over six consecutive hemodialysis sessions at recruitment. Results Hypertension was present in 68.8% of patients, and diabetes was present in 29.9% of patients. Supraventricular arrhythmias were recorded in 38 patients (49.3%); all of these were short, asymptomatic, and self-limiting. Age (hazard ratio, 1.04 per year; 95% confidence interval, 1.00 to 1.08) and right atrial enlargement (hazard ratio, 4.29; 95% confidence interval, 1.30 to 14.09) were associated with supraventricular arrhythmia in the multivariate analysis. During a median follow-up of 40 months, 57 patients died, and cardiovascular disease was the main cause of death (52.6%). The variables associated with all-cause mortality in the Cox model were age (hazard ratio, 1.04 per year; 95% confidence interval, 1.00 to 1.08), C-reactive protein (hazard ratio, 1.04 per 1 mg/L; 95% confidence interval, 1.00 to 1.08), and supraventricular arrhythmia (hazard ratio, 3.21; 95% confidence interval, 1.29 to 7.96). Patients with supraventricular arrhythmia also had a higher risk of nonfatal cardiovascular events (hazard ratio, 4.32; 95% confidence interval, 2.11 to 8.83) and symptomatic atrial fibrillation during follow-up (hazard ratio, 17.19; 95% confidence interval, 2.03 to 145.15). Conclusions The incidence of intradialysis supraventricular arrhythmia was high in our hemodialysis study population. Supraventricular arrhythmias were short, asymptomatic, and self-limiting, and although silent, these arrhythmias were independently associated with mortality and cardiovascular events. PMID:27697781

  8. Asymptomatic Intradialytic Supraventricular Arrhythmias and Adverse Outcomes in Patients on Hemodialysis.

    PubMed

    Verde, Eduardo; Pérez de Prado, Armando; López-Gómez, Juan M; Quiroga, Borja; Goicoechea, Marian; García-Prieto, Ana; Torres, Esther; Reque, Javier; Luño, José

    2016-12-07

    Supraventricular arrhythmias are associated with high morbidity and mortality. Nevertheless, this condition has received little attention in patients on hemodialysis. The objective of this study was to analyze the incidence of intradialysis supraventricular arrhythmia and its long-term prognostic value. We designed an observational and prospective study in a cohort of patients on hemodialysis with a 10-year follow-up period. All patients were recruited for study participation and were not recruited for clinical indications. The study population comprised 77 patients (42 men and 35 women; mean age =58±15 years old) with sinus rhythm monitored using a Holter electrocardiogram over six consecutive hemodialysis sessions at recruitment. Hypertension was present in 68.8% of patients, and diabetes was present in 29.9% of patients. Supraventricular arrhythmias were recorded in 38 patients (49.3%); all of these were short, asymptomatic, and self-limiting. Age (hazard ratio, 1.04 per year; 95% confidence interval, 1.00 to 1.08) and right atrial enlargement (hazard ratio, 4.29; 95% confidence interval, 1.30 to 14.09) were associated with supraventricular arrhythmia in the multivariate analysis. During a median follow-up of 40 months, 57 patients died, and cardiovascular disease was the main cause of death (52.6%). The variables associated with all-cause mortality in the Cox model were age (hazard ratio, 1.04 per year; 95% confidence interval, 1.00 to 1.08), C-reactive protein (hazard ratio, 1.04 per 1 mg/L; 95% confidence interval, 1.00 to 1.08), and supraventricular arrhythmia (hazard ratio, 3.21; 95% confidence interval, 1.29 to 7.96). Patients with supraventricular arrhythmia also had a higher risk of nonfatal cardiovascular events (hazard ratio, 4.32; 95% confidence interval, 2.11 to 8.83) and symptomatic atrial fibrillation during follow-up (hazard ratio, 17.19; 95% confidence interval, 2.03 to 145.15). The incidence of intradialysis supraventricular arrhythmia was high in our hemodialysis study population. Supraventricular arrhythmias were short, asymptomatic, and self-limiting, and although silent, these arrhythmias were independently associated with mortality and cardiovascular events. Copyright © 2016 by the American Society of Nephrology.

  9. Cardiac Arrhythmias in Experimental Syncope

    DTIC Science & Technology

    1958-11-01

    cardiac toward respiratory alkalosis . Regardless of arriythmias by stress procedures. It follows these two extremes in the assumed change in that previous...frequently induced by respiratory maneuvers without syncope. Intravenous aidministration of atropine appatently prevented recurrence of cardiac...arrhythmia induced by respiratory maneuvers. Significant cardiac arrhythmia was also noted in simple orthostatic syncope. Loss of consciousness presents a

  10. Atrial Arrhythmias in Astronauts. Summary of a NASA Summit

    NASA Technical Reports Server (NTRS)

    Barr, Yael; Watkins, Sharmila; Polk, J. D.

    2011-01-01

    This slide presentation reviews the findings of a panel of heart experts brought together to study if atrial arrhythmias more prevalent in astronauts, and potential risk factors that may predispose astronauts to atrial arrhythmias. The objective of the panel was to solicit expert opinion on screening, diagnosis, and treatment options, identify gaps in knowledge, and propose relevant research initiatives. While Atrial Arrhythmias occur in approximately the same percents in astronauts as in the general population, they seem to occur at younger ages in astronauts. Several reasons for this predisposition were given: gender, hypertension, endurance training, and triggering events. Potential Space Flight-Related Risk factors that may play a role in precipitating lone atrial fibrillation were reviewed. There appears to be no evidence that any variable of the space flight environment increases the likelihood of developing atrial arrhythmias during space flight.

  11. Controversies in Cardiovascular Research: Induced pluripotent stem cell-derived cardiomyocytes – boutique science or valuable arrhythmia model?

    PubMed Central

    Knollmann, Björn C

    2013-01-01

    As part of the series on Controversies in Cardiovascular Research, the article reviews the strengths and limitations of induced pluripotent stem cell-derived cardiomyocytes (iPSC-CM) as models of cardiac arrhythmias. Specifically, the article attempts to answer the following questions: Which clinical arrhythmias can be modeled by iPSC-CM? How well can iPSC-CM model adult ventricular myocytes? What are the strengths and limitations of published iPSC-CM arrhythmia models? What new mechanistic insight has been gained? What is the evidence that would support using iPSC-CM to personalize anti-arrhythmic drug therapy? The review also discusses the pros and cons of using the iPSC-CM technology for modeling specific genetic arrhythmia disorders such as long QT syndrome, Brugada Syndrome or Catecholaminergic Polymorphic Ventricular Tachycardia. PMID:23569106

  12. Riluzole reduces arrhythmias and myocardial damage induced by coronary occlusion in anaesthetized pigs.

    PubMed

    Weiss, Steven M; Dahlstrom, Jane E; Saint, David A

    2013-12-01

    The cardiac persistent sodium current (IN aP ) presents a novel target for cardiac ischaemic protection. Herein we investigated the effects of the IN aP blocker riluzole in a pig model of regional myocardial ischaemia. Landrace or Large White pigs were subjected to 3 h ligation of the left anterior descending coronary artery (LAD). Pigs received either saline (500 mL/h, i.v.) throughout the experiment (control; n = 7) or riluzole (2 mg/kg in 2 mL propylene glycol in 100 mL saline, i.v.; RIL; n = 7) between 15 and 5 min prior to ligation. The arrhythmia score was calculated in 5 min epochs. Myocardial damage was assessed using epicardial image analysis and histological sectioning. In the control group, all seven pigs developed premature ventricular contractions (PVC), seven developed non-sustained arrhythmias and six of seven developed sustained arrhythmias. Of the sustained arrhythmias, 23 of 28 instances were initiated by R-on-T extrasytoles (extrasystoles within the vulnerable period that can trigger re-entrant arrhythmias). In the RIL group, all seven pigs developed PVC, six of seven developed non-sustained arrhythmias and only three developed sustained arrhythmias, of which two of five instances were R-on-T initiated. The riluzole-treated pigs exhibited less myocardial damage than pigs in the control group (65% smaller surface area (P = 0.008) on gross epicardial inspection, 51% less oedema (P = 0.01), 53% less fibre waviness (P = 0.029) assessed by haematoxylin and eosin staining and 79% fewer fragmented nuclei (P = 0.009) assessed by terminal deoxyribonucleotidyl transferase-mediated dUTP-digoxigenin nick end-labelling). In conclusion, riluzole significantly reduced Phase 2 (the period associated with irreversible damage) ischaemic R-on-T triggered and non-R-on-T arrhythmias and myocardial damage occurring during the 3 h period of regional ischaemia. © 2013 Wiley Publishing Asia Pty Ltd.

  13. [A research on real-time ventricular QRS classification methods for single-chip-microcomputers].

    PubMed

    Peng, L; Yang, Z; Li, L; Chen, H; Chen, E; Lin, J

    1997-05-01

    Ventricular QRS classification is key technique of ventricular arrhythmias detection in single-chip-microcomputer based dynamic electrocardiogram real-time analyser. This paper adopts morphological feature vector including QRS amplitude, interval information to reveal QRS morphology. After studying the distribution of QRS morphology feature vector of MIT/BIH DB ventricular arrhythmia files, we use morphological feature vector cluster to classify multi-morphology QRS. Based on the method, morphological feature parameters changing method which is suitable to catch occasional ventricular arrhythmias is presented. Clinical experiments verify missed ventricular arrhythmia is less than 1% by this method.

  14. Extrasystoles: side effect of kangaroo care?

    PubMed

    Kluthe, Christof; Wauer, Roland R; Rüdiger, Mario

    2004-09-01

    To present an unpublished reason for an arrhythmic electrocardiogram (ECG) recording during kangaroo care in a preterm infant. Case report. Preterm infant. A preterm infant exhibited cardiac arrhythmia on the ECG monitor during kangaroo care, leading to interruption of kangarooing. Arrhythmia disappeared after placing the baby back into the incubator. The most likely reasons for arrhythmia were excluded. However, arrhythmia reappeared upon continuation of kangaroo care. ECG monitoring revealed the reason for the monitoring error. ECG monitoring during kangaroo care should cause error because of superimposed electric activity from the parent. Oxygen saturation represents a more reliable method of monitoring during kangaroo care.

  15. Automated Detection of Atrial Fibrillation Based on Time-Frequency Analysis of Seismocardiograms.

    PubMed

    Hurnanen, Tero; Lehtonen, Eero; Tadi, Mojtaba Jafari; Kuusela, Tom; Kiviniemi, Tuomas; Saraste, Antti; Vasankari, Tuija; Airaksinen, Juhani; Koivisto, Tero; Pankaala, Mikko

    2017-09-01

    In this paper, a novel method to detect atrial fibrillation (AFib) from a seismocardiogram (SCG) is presented. The proposed method is based on linear classification of the spectral entropy and a heart rate variability index computed from the SCG. The performance of the developed algorithm is demonstrated on data gathered from 13 patients in clinical setting. After motion artifact removal, in total 119 min of AFib data and 126 min of sinus rhythm data were considered for automated AFib detection. No other arrhythmias were considered in this study. The proposed algorithm requires no direct heartbeat peak detection from the SCG data, which makes it tolerant against interpersonal variations in the SCG morphology, and noise. Furthermore, the proposed method relies solely on the SCG and needs no complementary electrocardiography to be functional. For the considered data, the detection method performs well even on relatively low quality SCG signals. Using a majority voting scheme that takes five randomly selected segments from a signal and classifies these segments using the proposed algorithm, we obtained an average true positive rate of [Formula: see text] and an average true negative rate of [Formula: see text] for detecting AFib in leave-one-out cross-validation. This paper facilitates adoption of microelectromechanical sensor based heart monitoring devices for arrhythmia detection.

  16. Cardiac arrhythmias during or after epileptic seizures

    PubMed Central

    van der Lende, Marije; Surges, Rainer; Sander, Josemir W; Thijs, Roland D

    2016-01-01

    Seizure-related cardiac arrhythmias are frequently reported and have been implicated as potential pathomechanisms of Sudden Unexpected Death in Epilepsy (SUDEP). We attempted to identify clinical profiles associated with various (post)ictal cardiac arrhythmias. We conducted a systematic search from the first date available to July 2013 on the combination of two terms: ‘cardiac arrhythmias’ and ‘epilepsy’. The databases searched were PubMed, Embase (OVID version), Web of Science and COCHRANE Library. We attempted to identify all case reports and case series. We identified seven distinct patterns of (post)ictal cardiac arrhythmias: ictal asystole (103 cases), postictal asystole (13 cases), ictal bradycardia (25 cases), ictal atrioventricular (AV)-conduction block (11 cases), postictal AV-conduction block (2 cases), (post)ictal atrial flutter/atrial fibrillation (14 cases) and postictal ventricular fibrillation (3 cases). Ictal asystole had a mean prevalence of 0.318% (95% CI 0.316% to 0.320%) in people with refractory epilepsy who underwent video-EEG monitoring. Ictal asystole, bradycardia and AV-conduction block were self-limiting in all but one of the cases and seen during focal dyscognitive seizures. Seizure onset was mostly temporal (91%) without consistent lateralisation. Postictal arrhythmias were mostly found following convulsive seizures and often associated with (near) SUDEP. The contrasting clinical profiles of ictal and postictal arrhythmias suggest different pathomechanisms. Postictal rather than ictal arrhythmias seem of greater importance to the pathophysiology of SUDEP. PMID:26038597

  17. Risk of malignant arrhythmias in initially symptomatic patients with Wolff-Parkinson-White syndrome: results of a prospective long-term electrophysiological follow-up study.

    PubMed

    Pappone, Carlo; Vicedomini, Gabriele; Manguso, Francesco; Baldi, Mario; Pappone, Alessia; Petretta, Andrea; Vitale, Raffaele; Saviano, Massimo; Ciaccio, Cristiano; Giannelli, Luigi; Calovic, Zarko; Tavazzi, Luigi; Santinelli, Vincenzo

    2012-02-07

    The available amount of detailed long-term data in patients with Wolff-Parkinson-White syndrome is limited, and no prospective electrophysiological studies looking at predictors of malignant arrhythmia are available. Among 8575 symptomatic Wolff-Parkinson-White patients with atrioventricular reentrant tachycardia referred for electrophysiological test, 369 (mean age, 23±12.5 years) declined catheter ablation and were followed up. The primary end point of the study was to evaluate over a 5-year follow-up the predictors and characteristics of patients who develop malignant arrhythmias. After a mean follow-up of 42.1±10 months, malignant arrhythmias developed in 29 patients (mean age, 13.9±5.6 years; 26 male), resulting in presyncope/syncope (25 patients), hemodynamic collapse (3 patients), or cardiac arrest caused by ventricular fibrillation (1 patient). Of the remaining 340 patients, 168 (mean age, 34.2±9.0 years) remained asymptomatic up to 5 years, and 172 (mean age, 13.6±5.1 years) had benign recurrence, including sustained atrioventricular reentrant tachycardia (132 patients) or atrial fibrillation (40 patients). Compared with the group with no malignant arrhythmias, the group with malignant arrhythmias showed shorter accessory-pathway effective refractory period (P<0.001) and more often exhibited multiple accessory pathways (P<0.001), and atrioventricular reentrant tachycardia triggering sustained pre-excited atrial fibrillation was more frequently inducible (P<0.001). Multivariable analysis demonstrated that short accessory-pathway effective refractory period (P<0.001) and atrioventricular reentrant tachycardia triggering sustained pre-excited atrial fibrillation (P<0.001) were independent predictors of malignant arrhythmias. Symptomatic patients with Wolff-Parkinson-White syndrome generally have a good outcome, and predictors of malignant arrhythmias are similar to those reported for asymptomatic patients with ventricular pre-excitation.

  18. The Application of a Massively Parallel Computer to the Simulation of Electrical Wave Propagation Phenomena in the Heart Muscle Using Simplified Models

    NASA Technical Reports Server (NTRS)

    Karpoukhin, Mikhii G.; Kogan, Boris Y.; Karplus, Walter J.

    1995-01-01

    The simulation of heart arrhythmia and fibrillation are very important and challenging tasks. The solution of these problems using sophisticated mathematical models is beyond the capabilities of modern super computers. To overcome these difficulties it is proposed to break the whole simulation problem into two tightly coupled stages: generation of the action potential using sophisticated models. and propagation of the action potential using simplified models. The well known simplified models are compared and modified to bring the rate of depolarization and action potential duration restitution closer to reality. The modified method of lines is used to parallelize the computational process. The conditions for the appearance of 2D spiral waves after the application of a premature beat and the subsequent traveling of the spiral wave inside the simulated tissue are studied.

  19. Atrial Arrhythmias and Their Implications for Space Flight - Introduction

    NASA Technical Reports Server (NTRS)

    Polk, J. D.; Barr, Y. R.; Bauer, P.; Hamilton, D. R.; Kerstman, E.; Tarver, B.

    2010-01-01

    This panel will discuss the implications of atrial arrhythmias in astronauts from a variety of perspectives; including historical data, current practices, and future challenges for exploration class missions. The panelists will present case histories, outline the evolution of current NASA medical standards for atrial arrhythmias, discuss the use of predictive tools, and consider potential challenges for current and future missions.

  20. Research and development of the device for diagnostics of arrhythmia

    NASA Astrophysics Data System (ADS)

    Lezhnina, I. A.; Boyakhchyan, A. A.; Overchuk, K. V.; Uvarov, A. A.

    2017-08-01

    The article describes the results of the research for sensors optimal arrangement during one limb ECG detection. The found placement provides the registration of the enough quality signal sufficient for the diagnosis of arrhythmia, the QRS complex is clearly recognized. Authors also show the test results of the device developed for the diagnosis of arrhythmia and sudden cardiac death.

  1. Statins as anti-arrhythmics: a systematic review part II: effects on risk of ventricular arrhythmias.

    PubMed

    Abuissa, Hussam; O'Keefe, James H; Bybee, Kevin A

    2009-10-01

    Recent studies have demonstrated that statins may possess anti-arrhythmic properties in addition to their lipid-lowering effects. Studies which reported the association of statins with the incidence of ventricular arrhythmias were identified through a systematic review of the published literature. Statins have been associated with a significant reductions in ventricular arrhythmia in cardiomyopathy patients with an implantable cardioverter defibrillator, although randomized trials have not been completed. Published data suggests that statins may possess anti-arrhythmic properties that reduce the propensity for ventricular arrhythmias. Most of this data is observational; more randomized, placebo-controlled trials are needed.

  2. Cardiac arrhythmias during exercise testing in healthy men.

    NASA Technical Reports Server (NTRS)

    Beard, E. F.; Owen, C. A.

    1973-01-01

    Clinically healthy male executives who participate in a long-term physical conditioning program have demonstrated cardiac arrhythmia during and after periodic ergometric testing at submaximal and maximal levels. In 1,385 tests on 248 subjects, it was found that 34% of subjects demonstrated an arrhythmia at some time and 13% of subjects developed arrhythmia on more than one test. Premature systoles of ventricular origin were most common, but premature systoles of atrial origin, premature systoles of junctional origin, paroxysmal atrial tachycardia, atrioventricular block, wandering pacemaker, and pre-excitation were also seen. Careful post-test monitoring and pulse rate regulated training sessions are suggested for such programs.

  3. A troubled beginning: evolving concepts of an old arrhythmia.

    PubMed

    Hanon, Sam; Shapiro, Michael; Schweitzer, Paul

    2005-07-01

    The development of the sphygmograph in the nineteenth century marked the beginning of graphic registration of the arterial and venous pulse. Mackenzie, among other investigators, used this technique to study cardiac rhythm. In the early 20th century, Einthoven developed the electrocardiogram, which replaced the less sophisticated arterial and venous registrations of cardiac events and allowed for more detailed arrhythmia analysis. Interestingly, the early study of cardiac arrhythmias was obscured by misinterpretation. Specifically, atrial fibrillation stands out as a rhythm that was extensively studied though misconstrued in its early history. What follows is an in-depth consideration of the original investigations and evolving theories of this important arrhythmia.

  4. [Catheter ablation in patients with refractory cardiac arrhythmias with radiofrequency techniques].

    PubMed

    de Paola, A A; Balbão, C E; Silva Netto, O; Mendonça, A; Villacorta, H; Vattimo, A C; Souza, I A; Guiguer Júnior, N; Portugal, O P; Martinez Filho, E E

    1993-02-01

    evaluate the efficacy of radiofrequency catheter ablation in patients with refractory cardiac arrhythmias. twenty patients with refractory cardiac arrhythmias were undertaken to electrophysiologic studies for diagnosis and radiofrequency catheter ablation of their reentrant arrhythmias. Ten patients were men and 10 women with ages varying from 13 to 76 years (mean = 42.4 years). Nineteen patients had supraventricular tachyarrhythmias: One patient had atrial tachycardia and 1 atrial fibrillation with rapid ventricular rate, 5 patients had reentrant nodal tachycardia, 12 patients had reentrant atrioventricular tachycardia and 1 patient had right ventricular outflow tract tachycardia. the mean time of the procedure was 4.1 hours. The radiofrequency current energy applied was 40-50 V for 30-40 seconds. Ablation was successful in 18/20 (90%) patients; in 15/18 (83%) of successfully treated patients the same study was done for diagnosis and radiofrequency ablation. One patient had femoral arterial occlusion and was treated with no significant sequelae. During a mean follow-up of 4 months no preexcitation or reentrant tachycardia occurred. the results of our experience with radiofrequency catheter ablation of cardiac arrhythmias suggest that this technique can benefit an important number of patients with cardiac arrhythmias.

  5. The association between domperidone and ventricular arrhythmia in the postpartum period.

    PubMed

    Smolina, Kate; Mintzes, Barbara; Hanley, Gillian E; Oberlander, Tim F; Morgan, Steven G

    2016-10-01

    The aim of this study is to examine the relationship between domperidone (commonly used off-label for lactation stimulation), ventricular arrhythmia and all-cause mortality during the postpartum period. This is a retrospective, population-based cohort study of all women with a live birth between 1 January 2002 and 31 December 2011 in British Columbia, Canada. Cox proportional hazards models, yielding hazard ratios (HRs), were used to estimate the risk of hospitalization for ventricular arrhythmia associated with domperidone exposure within six months postpartum. The study population consisted of 225 532 women with 320 351 live births. There was only one death during the six-month postpartum period among the study population, and thus we did not perform any analyses of all-cause mortality. We identified 21 hospitalizations for ventricular arrhythmia. Adjusting for age, smoking and prior history of ventricular arrhythmia and cardiovascular disease, the risk of ventricular arrhythmia hospitalization was approximately double among those exposed to domperidone, but the results were not statistically significant (HR = 2.25, 95%CI 0.84-6.01). Adjustment for body mass index in the 74% of women for whom it was known further reduced the association (HR = 1.69, 95%CI 0.48-5.96). We found a possible association between exposure to domperidone and hospitalization for ventricular arrhythmia among a cohort of women who have recently given birth. Future studies are needed to confirm this association. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  6. ECG during helicopter underwater escape training.

    PubMed

    Tipton, Michael J; Gibbs, Peter; Brooks, Chris; Roiz de Sa, Dan; Reilly, Tara J

    2010-04-01

    Coincidental stimulation of the sympathetic and parasympathetic nervous system can cause "autonomic conflict" and consequent cardiac arrhythmias. The present study tested the hypotheses that: 1) cardiac arrhythmias would be seen in those undertaking helicopter underwater escape training (HUET); 2) the occurrence of arrhythmias in individuals could be predicted; and 3) the heart rate response to HUET would habituate with repeated runs. There were 26 male volunteers who each undertook 5 HUET submersions into water at 29.5 degrees C, with each run separated by 10 min. Each submersion included a 3-min, 40-s pre-submersion period, a 10-s submersion, and 40-s post-submersion period. Participants wore a three-lead telemetric ECG system beneath an immersion suit and underclothing. Skin temperature was measured in one participant. Each participant undertook tests to establish their autonomic function, including heart rate variability, face immersion, cold pressor test, and aerobic capacity assessment. The heart rate response to HUET was reduced by the fourth run when compared to the first run. Across all runs, 32 cardiac arrhythmias were identified (25%) in 22 different participants; all but 6 of the arrhythmias occurred just after submersion. Only aerobic fitness appeared inversely associated with the occurrence of arrhythmias. The heart rate response to HUET habituates. HUET produces cardiac arrhythmias; these are asymptomatic and probably of little clinical significance in young, fit individuals. It remains to be seen if this is the case with either an older, less fit cohort of people or in those undertaking longer breath holds in colder water.

  7. Ambient Air Pollution and Daily Outpatient Visits for Cardiac Arrhythmia in Shanghai, China

    PubMed Central

    Zhao, Ang; Chen, Renjie; Kuang, Xingya; Kan, Haidong

    2014-01-01

    Background Cardiac arrhythmias are cardiac rhythm disorders that comprise an important public health problem. Few prior studies have examined the association between ambient air pollution and arrhythmias in general populations in mainland China. Methods We performed a time-series analysis to investigate the short-term association between air pollution (particulate matter with an aerodynamic diameter less than 10 µm [PM10], sulfur dioxide [SO2], and nitrogen dioxide [NO2]) and outpatient visits for arrhythmia in Shanghai, China. We applied the over-dispersed Poisson generalized additive model to analyze the associations after control for seasonality, day of the week, and weather conditions. We then stratified the analyses by age, gender, and season. Results We identified a total of 56 940 outpatient visits for cardiac arrhythmia. A 10-µg/m3 increase in the present-day concentrations of PM10, SO2, and NO2 corresponded to increases of 0.56% (95% CI 0.42%, 0.70%), 2.07% (95% CI 1.49%, 2.64%), and 2.90% (95% CI 2.53%, 3.27%), respectively, in outpatient arrhythmia visits. The associations were stronger in older people (aged ≥65 years) and in females. This study provides the first evidence that ambient air pollution is significantly associated with increased risk of cardiac arrhythmia in mainland China. Conclusions Our analyses provide evidence that the current air pollution levels have an adverse effect on cardiovascular health and strengthened the rationale for further limiting air pollution levels in the city. PMID:24835409

  8. Structural contributions to fibrillatory rotors in a patient-derived computational model of the atria.

    PubMed

    Gonzales, Matthew J; Vincent, Kevin P; Rappel, Wouter-Jan; Narayan, Sanjiv M; McCulloch, Andrew D

    2014-11-01

    The aim of this study was to investigate structural contributions to the maintenance of rotors in human atrial fibrillation (AF) and possible mechanisms of termination. A three-dimensional human biatrial finite element model based on patient-derived computed tomography and arrhythmia observed at electrophysiology study was used to study AF. With normal physiological electrical conductivity and effective refractory periods (ERPs), wave break failed to sustain reentrant activity or electrical rotors. With depressed excitability, decreased conduction anisotropy, and shorter ERP characteristic of AF, reentrant rotors were readily maintained. Rotors were transiently or permanently trapped by fibre discontinuities on the lateral wall of the right atrium near the tricuspid valve orifice and adjacent to the crista terminalis, both known sites of right atrial arrhythmias. Modelling inexcitable regions near the rotor tip to simulate fibrosis anchored the rotors, converting the arrhythmia to macro-reentry. Accordingly, increasing the spatial core of inexcitable tissue decreased the frequency of rotation, widened the excitable gap, and enabled an external wave to impinge on the rotor core and displace the source. These model findings highlight the importance of structural features in rotor dynamics and suggest that regions of fibrosis may anchor fibrillatory rotors. Increasing extent of fibrosis and scar may eventually convert fibrillation to excitable gap reentry. Such macro-reentry can then be eliminated by extending the obstacle or by external stimuli that penetrate the excitable gap. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.

  9. ECG-based 4D-dose reconstruction of cardiac arrhythmia ablation with carbon ion beams: application in a porcine model

    NASA Astrophysics Data System (ADS)

    Richter, Daniel; Immo Lehmann, H.; Eichhorn, Anna; Constantinescu, Anna M.; Kaderka, Robert; Prall, Matthias; Lugenbiel, Patrick; Takami, Mitsuru; Thomas, Dierk; Bert, Christoph; Durante, Marco; Packer, Douglas L.; Graeff, Christian

    2017-09-01

    Noninvasive ablation of cardiac arrhythmia by scanned particle radiotherapy is highly promising, but especially challenging due to cardiac and respiratory motion. Irradiations for catheter-free ablation in intact pigs were carried out at the GSI Helmholtz Center in Darmstadt using scanned carbon ions. Here, we present real-time electrocardiogram (ECG) data to estimate time-resolved (4D) delivered dose. For 11 animals, surface ECGs and temporal structure of beam delivery were acquired during irradiation. R waves were automatically detected from surface ECGs. Pre-treatment ECG-triggered 4D-CT phases were synchronized to the R-R interval. 4D-dose calculation was performed using GSI’s in-house 4D treatment planning system. Resulting dose distributions were assessed with respect to coverage (D95 and V95), heterogeneity (HI  =  D5-D95) and normal tissue exposure. Final results shown here were performed offline, but first calculations were started shortly after irradiation The D95 for TV and PTV was above 95% for 10 and 8 out of 11 animals, respectively. HI was reduced for PTV versus TV volumes, especially for some of the animals targeted at the atrioventricular junction, indicating residual interplay effects due to cardiac motion. Risk structure exposure was comparable to static and 4D treatment planning simulations. ECG-based 4D-dose reconstruction is technically feasible in a patient treatment-like setting. Further development of the presented approach, such as real-time dose calculation, may contribute to safe, successful treatments using scanned ion beams for cardiac arrhythmia ablation.

  10. From mitochondrial ion channels to arrhythmias in the heart: computational techniques to bridge the spatio-temporal scales

    PubMed Central

    Plank, Gernot; Zhou, Lufang; Greenstein, Joseph L; Cortassa, Sonia; Winslow, Raimond L; O'Rourke, Brian; Trayanova, Natalia A

    2008-01-01

    Computer simulations of electrical behaviour in the whole ventricles have become commonplace during the last few years. The goals of this article are (i) to review the techniques that are currently employed to model cardiac electrical activity in the heart, discussing the strengths and weaknesses of the various approaches, and (ii) to implement a novel modelling approach, based on physiological reasoning, that lifts some of the restrictions imposed by current state-of-the-art ionic models. To illustrate the latter approach, the present study uses a recently developed ionic model of the ventricular myocyte that incorporates an excitation–contraction coupling and mitochondrial energetics model. A paradigm to bridge the vastly disparate spatial and temporal scales, from subcellular processes to the entire organ, and from sub-microseconds to minutes, is presented. Achieving sufficient computational efficiency is the key to success in the quest to develop multiscale realistic models that are expected to lead to better understanding of the mechanisms of arrhythmia induction following failure at the organelle level, and ultimately to the development of novel therapeutic applications. PMID:18603526

  11. Nonlinear physics of electrical wave propagation in the heart: a review

    NASA Astrophysics Data System (ADS)

    Alonso, Sergio; Bär, Markus; Echebarria, Blas

    2016-09-01

    The beating of the heart is a synchronized contraction of muscle cells (myocytes) that is triggered by a periodic sequence of electrical waves (action potentials) originating in the sino-atrial node and propagating over the atria and the ventricles. Cardiac arrhythmias like atrial and ventricular fibrillation (AF,VF) or ventricular tachycardia (VT) are caused by disruptions and instabilities of these electrical excitations, that lead to the emergence of rotating waves (VT) and turbulent wave patterns (AF,VF). Numerous simulation and experimental studies during the last 20 years have addressed these topics. In this review we focus on the nonlinear dynamics of wave propagation in the heart with an emphasis on the theory of pulses, spirals and scroll waves and their instabilities in excitable media with applications to cardiac modeling. After an introduction into electrophysiological models for action potential propagation, the modeling and analysis of spatiotemporal alternans, spiral and scroll meandering, spiral breakup and scroll wave instabilities like negative line tension and sproing are reviewed in depth and discussed with emphasis on their impact for cardiac arrhythmias.

  12. Bench study of the accuracy of a commercial AED arrhythmia analysis algorithm in the presence of electromagnetic interferences.

    PubMed

    Jekova, Irena; Krasteva, Vessela; Ménétré, Sarah; Stoyanov, Todor; Christov, Ivaylo; Fleischhackl, Roman; Schmid, Johann-Jakob; Didon, Jean-Philippe

    2009-07-01

    This paper presents a bench study on a commercial automated external defibrillator (AED). The objective was to evaluate the performance of the defibrillation advisory system and its robustness against electromagnetic interferences (EMI) with central frequencies of 16.7, 50 and 60 Hz. The shock advisory system uses two 50 and 60 Hz band-pass filters, an adaptive filter to identify and suppress 16.7 Hz interference, and a software technique for arrhythmia analysis based on morphology and frequency ECG parameters. The testing process includes noise-free ECG strips from the internationally recognized MIT-VFDB ECG database that were superimposed with simulated EMI artifacts and supplied to the shock advisory system embedded in a real AED. Measurements under special consideration of the allowed variation of EMI frequency (15.7-17.4, 47-52, 58-62 Hz) and amplitude (1 and 8 mV) were performed to optimize external validity. The accuracy was reported using the American Heart Association (AHA) recommendations for arrhythmia analysis performance. In the case of artifact-free signals, the AHA performance goals were exceeded for both sensitivity and specificity: 99% for ventricular fibrillation (VF), 98% for rapid ventricular tachycardia (VT), 90% for slow VT, 100% for normal sinus rhythm, 100% for asystole and 99% for other non-shockable rhythms. In the presence of EMI, the specificity for some non-shockable rhythms (NSR, N) may be affected in some specific cases of a low signal-to-noise ratio and extreme frequencies, leading to a drop in the specificity with no more than 7% point. The specificity for asystole and the sensitivity for VF and rapid VT in the presence of any kind of 16.7, 50 or 60 Hz EMI simulated artifact were shown to reach the equivalence of sensitivity required for non-noisy signals. In conclusion, we proved that the shock advisory system working in a real AED operates accurately according to the AHA recommendations without artifacts and in the presence of EMI. The results may be affected for specificity in the case of a low signal-to-noise ratio or in some extreme frequency setting.

  13. A second-generation computational modeling of cardiac electrophysiology: response of action potential to ionic concentration changes and metabolic inhibition.

    PubMed

    Alaa, Nour Eddine; Lefraich, Hamid; El Malki, Imane

    2014-10-21

    Cardiac arrhythmias are becoming one of the major health care problem in the world, causing numerous serious disease conditions including stroke and sudden cardiac death. Furthermore, cardiac arrhythmias are intimately related to the signaling ability of cardiac cells, and are caused by signaling defects. Consequently, modeling the electrical activity of the heart, and the complex signaling models that subtend dangerous arrhythmias such as tachycardia and fibrillation, necessitates a quantitative model of action potential (AP) propagation. Yet, many electrophysiological models, which accurately reproduce dynamical characteristic of the action potential in cells, have been introduced. However, these models are very complex and are very time consuming computationally. Consequently, a large amount of research is consecrated to design models with less computational complexity. This paper is presenting a new model for analyzing the propagation of ionic concentrations and electrical potential in space and time. In this model, the transport of ions is governed by Nernst-Planck flux equation (NP), and the electrical interaction of the species is described by a new cable equation. These set of equations form a system of coupled partial nonlinear differential equations that is solved numerically. In the first we describe the mathematical model. To realize the numerical simulation of our model, we proceed by a finite element discretization and then we choose an appropriate resolution algorithm. We give numerical simulations obtained for different input scenarios in the case of suicide substrate reaction which were compared to those obtained in literature. These input scenarios have been chosen so as to provide an intuitive understanding of dynamics of the model. By accessing time and space domains, it is shown that interpreting the electrical potential of cell membrane at steady state is incorrect. This model is general and applies to ions of any charge in space and time domains. The results obtained show a complete agreement with literature findings and also with the physical interpretation of the phenomenon. Furthermore, various numerical experiments are presented to confirm the accuracy, efficiency and stability of the proposed method. In particular, we show that the scheme is second-order accurate in space.

  14. The effect of inhibitors of endogenous opioid degradation, bacitracin, bestatin, captopril, and D-phenylalanine, on digoxin-induced arrhythmias in guinea pigs.

    PubMed

    Rabkin, S W; Redston, M

    1989-08-01

    The purpose of this study was to investigate the effect of inhibition of endogenous opioid degradation on digitalis-induced arrhythmias, utilizing the inhibitors bacitracin, bestatin, captopril, and D-phenylalanine. Guinea pigs, anesthetized with pentobarbital, 50 mg/kg i.p., and breathing spontaneously received intracerebroventricular (i.c.v.) injection of bacitracin (6.8 mg/kg), bestatin (1 mg/kg), captopril (2 mg/kg), D-phenylalanine (1.2 mg/kg) or the diluent, saline. Digitalis arrhythmias were induced by a 50 micrograms/kg i.v. bolus of digoxin followed by 500 micrograms.kg-1.h-1 i.v. Bacitracin and bestatin, but not captopril or D-phenylalanine, significantly (p less than 0.05) altered the relationship between the digoxin dose and the first occurrence of arrhythmias, i.e., digoxin-induced ventricular arrhythmias became manifest at lower digoxin doses. The mean digoxin dose and ED50s, at which arrhythmias first occurred, were significantly (p less than 0.05) reduced by bacitracin and bestatin. The findings were similar for fatal arrhythmias, although D-phenylalanine appeared to decrease the digoxin dose at the development of fatal arrhythmias. The opioid antagonist naloxone, in a 50 micrograms/kg bolus and 50 micrograms.kg-1.h-1 i.c.v., completely prevented these effects of bacitracin and reduced the effect of bestatin. The relationship to arrhythmias could not be ascribed to an effect on blood pressure, as the blood pressure response to digoxin was the same in bestatin, D-phenylalanine, and control groups. To examine whether systemic administration of an inhibitor of opioid degradation had similar effects, a second protocol was selected with systemic administration of bacitracin because it altered the dose effect relationship after i.c.v. administration and systemic concentrations could be readily attained. Bacitracin, in a 13.5 mg/kg i.v. bolus and 135 mg.kg-1.h-1 i.v., was followed by 100 micrograms/kg digoxin i.v. every 15 min.(ABSTRACT TRUNCATED AT 250 WORDS)

  15. An umbilical venous catheter complication presented as acute abdomen: case report.

    PubMed

    Oztan, Mustafa O; Ilhan, Ozkan; Abay, Elif; Koyluoglu, Gokhan

    2016-12-01

    Umbilical venous catheterization has become a widely accepted intravenous route for premature babies. These catheters allow administration of parenteral nutrition and medication and facilitate blood sampling. Besides these benefits, they also have significant potential complications like portal vein thrombosis, infection, vascular or hepatic injury, arrhythmia and sepsis. One of the rare but important complication is extravasation of the fluids due to misplacement of the catheter. The typical symptoms of this condition are sudden deterioration, hepatic enlargement, hematocrit drop, hypotension and abdominal distension. We herein present a premature newborn with unusual acute abdomen findings suggesting a surgical pathology after the extravasation of total parenteral nutrition into the abdomen. Sociedad Argentina de Pediatría.

  16. [Lead compound optimization strategy(5) – reducing the hERG cardiac toxicity in drug development].

    PubMed

    Zhou, Sheng-bin; Wang, Jiang; Liu, Hong

    2016-10-01

    The potassium channel encoded by the human ether-a-go-go related gene(hERG) plays a very important role in the physiological and pathological processes in human. hERG potassium channel determines the outward currents which facilitate the repolarization of the myocardial cells. Some drugs were withdrawn from the market for the serious side effect of long QT interval and arrhythmia due to blockade of hERG channel. The strategies for lead compound optimization are to reduce inhibitory activity of hERG potassium channel and decrease cardiac toxicity. These methods include reduction of lipophilicity and basicity of amines, introduction of hydroxyl and acidic groups, and restricting conformation.

  17. Prevention of thiopental and thiopental/halothane cardiac sensitization to epinephrine in the sheep.

    PubMed Central

    Rezakhani, A; Edjtehadi, M; Szabuniewicz, M

    1977-01-01

    The effects of epinephrine (5 microgram/kg of body weight) on ten unanesthetized sheep were experimentally tested: all sheep displayed serious arrhythmias. Sheep anesthetized with thiopental and thiopental/halothane combination displayed cardiac arrhythmias of the order of 10% and 20% respectively. Challenge injections of epinephrine (5 microgram/kg of body weight) to ten sheep anesthetized with thiopental, and to the same number of animals after 45 minutes of anesthesia with thiopental/halothane, produced serious arrhythmias. However, following preanesthetic treatment with acepromazine maleate (0.5 mg/kg) to 15 sheep, serious arrhythmias were prevented in all of them when they were given arrhythmic doses of epinephrine. Images Fig. 2. PMID:922556

  18. [Observation of antiarrhythmic effects of Cinnamomum migao H. W. Li on experimental arrhythmia].

    PubMed

    Sui, Y; Qiu, D; Xie, C; Chen, K

    1998-08-01

    To investigate the effects of Cinnamomum migao on experimental arrhythmia. Arrhythmic models of mice, rabbits, guinea pigs and rats were built using chloroform(Chl), adrenalin(Adr), strophanthin-K (Spt-K) and barium chloride (BaCl2). The affected animals were divided randomly into three groups: control group, Cinnamomum migao (CV-3) group and mexiletine (MXL) group, so as to observe and compare the antiarrhythmic effects. CV-3 could reduce the incidence of ventricular fibrillation caused by ch1 in mice and the ventricular tachycardia induced by Adr in rabbits, delay the onset time of this arrhythmia, increase the arrhythmic doses of Spt-K in guinea pigs, reduce the incidence of some arrhythmia caused by BaCl2 in rats and slow down their heart rate. CV-3 has obvious antiarrhythmic effects on experimental arrhythmia. The mechanism of these effects is probably related to the arrest of the intraflow of Na+, Ca2+ in the cardiac cells and the depression of their cardiac autoarrhythmicity and conductivity.

  19. Evidence of reversible bradycardia and arrhythmias caused by immunogenic proteins secreted by T. cruzi in isolated rat hearts.

    PubMed

    Rodríguez-Angulo, Héctor O; Toro-Mendoza, Jhoan; Marques, Juan A; Concepción, Juan L; Bonfante-Cabarcas, Rafael; Higuerey, Yoliver; Thomas, Luz E; Balzano-Nogueira, Leandro; López, José R; Mijares, Alfredo

    2015-02-01

    Chagas cardiomyopathy, caused by the protozoan Trypanosoma cruzi, is characterized by alterations in intracellular ion, heart failure and arrhythmias. Arrhythmias have been related to sudden death, even in asymptomatic patients, and their molecular mechanisms have not been fully elucidated. The aim of this study is to demonstrate the effect of proteins secreted by T. cruzi on healthy, isolated beating rat heart model under a non-damage-inducing protocol. We established a non-damage-inducing recirculation-reoxygenation model where ultrafiltrate fractions of conditioned medium control or conditioned infected medium were perfused at a standard flow rate and under partial oxygenation. Western blotting with chagasic patient serum was performed to determine the antigenicity of the conditioned infected medium fractions. We observed bradycardia, ventricular fibrillation and complete atrioventricular block in hearts during perfusion with >50 kDa conditioned infected culture medium. The preincubation of conditioned infected medium with chagasic serum abolished the bradycardia and arrhythmias. The proteins present in the conditioned infected culture medium of >50 kDa fractions were recognized by the chagasic patient sera associated with arrhythmias. These results suggest that proteins secreted by T. cruzi are involved in Chagas disease arrhythmias and may be a potential biomarker in chagasic patients.

  20. Quantitative Assessment of Arrhythmia Using Non-linear Approach: A Non-invasive Prognostic Tool

    NASA Astrophysics Data System (ADS)

    Chakraborty, Monisha; Ghosh, Dipak

    2017-12-01

    Accurate prognostic tool to identify severity of Arrhythmia is yet to be investigated, owing to the complexity of the ECG signal. In this paper, we have shown that quantitative assessment of Arrhythmia is possible using non-linear technique based on "Hurst Rescaled Range Analysis". Although the concept of applying "non-linearity" for studying various cardiac dysfunctions is not entirely new, the novel objective of this paper is to identify the severity of the disease, monitoring of different medicine and their dose, and also to assess the efficiency of different medicine. The approach presented in this work is simple which in turn will help doctors in efficient disease management. In this work, Arrhythmia ECG time series are collected from MIT-BIH database. Normal ECG time series are acquired using POLYPARA system. Both time series are analyzed in thelight of non-linear approach following the method "Rescaled Range Analysis". The quantitative parameter, "Fractal Dimension" (D) is obtained from both types of time series. The major finding is that Arrhythmia ECG poses lower values of D as compared to normal. Further, this information can be used to access the severity of Arrhythmia quantitatively, which is a new direction of prognosis as well as adequate software may be developed for the use of medical practice.

  1. Quantitative Assessment of Arrhythmia Using Non-linear Approach: A Non-invasive Prognostic Tool

    NASA Astrophysics Data System (ADS)

    Chakraborty, Monisha; Ghosh, Dipak

    2018-04-01

    Accurate prognostic tool to identify severity of Arrhythmia is yet to be investigated, owing to the complexity of the ECG signal. In this paper, we have shown that quantitative assessment of Arrhythmia is possible using non-linear technique based on "Hurst Rescaled Range Analysis". Although the concept of applying "non-linearity" for studying various cardiac dysfunctions is not entirely new, the novel objective of this paper is to identify the severity of the disease, monitoring of different medicine and their dose, and also to assess the efficiency of different medicine. The approach presented in this work is simple which in turn will help doctors in efficient disease management. In this work, Arrhythmia ECG time series are collected from MIT-BIH database. Normal ECG time series are acquired using POLYPARA system. Both time series are analyzed in thelight of non-linear approach following the method "Rescaled Range Analysis". The quantitative parameter, "Fractal Dimension" (D) is obtained from both types of time series. The major finding is that Arrhythmia ECG poses lower values of D as compared to normal. Further, this information can be used to access the severity of Arrhythmia quantitatively, which is a new direction of prognosis as well as adequate software may be developed for the use of medical practice.

  2. Evidence of Reversible Bradycardia and Arrhythmias Caused by Immunogenic Proteins Secreted by T. cruzi in Isolated Rat Hearts

    PubMed Central

    Rodríguez-Angulo, Héctor O.; Toro-Mendoza, Jhoan; Marques, Juan A.; Concepción, Juan L.; Bonfante-Cabarcas, Rafael; Higuerey, Yoliver; Thomas, Luz E.; Balzano-Nogueira, Leandro; López, José R.; Mijares, Alfredo

    2015-01-01

    Rationale Chagas cardiomyopathy, caused by the protozoan Trypanosoma cruzi, is characterized by alterations in intracellular ion, heart failure and arrhythmias. Arrhythmias have been related to sudden death, even in asymptomatic patients, and their molecular mechanisms have not been fully elucidated. Objective The aim of this study is to demonstrate the effect of proteins secreted by T. cruzi on healthy, isolated beating rat heart model under a non-damage-inducing protocol. Methods and Results We established a non-damage-inducing recirculation-reoxygenation model where ultrafiltrate fractions of conditioned medium control or conditioned infected medium were perfused at a standard flow rate and under partial oxygenation. Western blotting with chagasic patient serum was performed to determine the antigenicity of the conditioned infected medium fractions. We observed bradycardia, ventricular fibrillation and complete atrioventricular block in hearts during perfusion with >50 kDa conditioned infected culture medium. The preincubation of conditioned infected medium with chagasic serum abolished the bradycardia and arrhythmias. The proteins present in the conditioned infected culture medium of >50 kDa fractions were recognized by the chagasic patient sera associated with arrhythmias. Conclusions These results suggest that proteins secreted by T. cruzi are involved in Chagas disease arrhythmias and may be a potential biomarker in chagasic patients. PMID:25647069

  3. Possible influence of the polarity reversal of the solar magnetic field on the various types of arrhythmias

    NASA Astrophysics Data System (ADS)

    Giannaropoulou, E.; Papailiou, M.; Mavromichalaki, H.; Gigolashvili, M.; Tvildiani, L.; Janashia, K.; Preka-Papadema, P.; Papadima, Th

    2013-02-01

    Over the last few years various researches have reached the conclusion that cosmic ray variations and geomagnetic disturbances are related to the condition of the human physiological state. In this study medical data concerning the number of incidents of different types of cardiac arrhythmias for the time period 1983 - 1992 which refer to 1902 patients in Tbilisi, Georgia were used. The smoothing method and the Pearson r-coefficients were used to examine the possible effect of different solar and geomagnetic activity parameters and cosmic ray intensity variations on the different types of arrhythmias. The time interval under examination was separated into two different time periods which coincided with the polarity reversal of the solar magnetic field that occurred in the years 1989-1990 and as a result a different behavior of all the above mentioned parameters as well as of the different types of arrhythmias was noticed during the two time intervals. In addition, changing of polarity sign of the solar magnetic field was found to affect the sign of correlation between the incidence of arrhythmias and the aforementioned parameters. The primary and secondary maxima observed in the solar parameters during the solar cycle 22, also appeared in several types of arrhythmias with a time lag of about five months.

  4. Severe Hypoglycemia–Induced Lethal Cardiac Arrhythmias Are Mediated by Sympathoadrenal Activation

    PubMed Central

    Reno, Candace M.; Daphna-Iken, Dorit; Chen, Y. Stefanie; VanderWeele, Jennifer; Jethi, Krishan; Fisher, Simon J.

    2013-01-01

    For people with insulin-treated diabetes, severe hypoglycemia can be lethal, though potential mechanisms involved are poorly understood. To investigate how severe hypoglycemia can be fatal, hyperinsulinemic, severe hypoglycemic (10–15 mg/dL) clamps were performed in Sprague-Dawley rats with simultaneous electrocardiogram monitoring. With goals of reducing hypoglycemia-induced mortality, the hypotheses tested were that: 1) antecedent glycemic control impacts mortality associated with severe hypoglycemia; 2) with limitation of hypokalemia, potassium supplementation could limit hypoglycemia-associated deaths; 3) with prevention of central neuroglycopenia, brain glucose infusion could prevent hypoglycemia-associated arrhythmias and deaths; and 4) with limitation of sympathoadrenal activation, adrenergic blockers could prevent hypoglycemia-induced arrhythmic deaths. Severe hypoglycemia–induced mortality was noted to be worsened by diabetes, but recurrent antecedent hypoglycemia markedly improved the ability to survive an episode of severe hypoglycemia. Potassium supplementation tended to reduce mortality. Severe hypoglycemia caused numerous cardiac arrhythmias including premature ventricular contractions, tachycardia, and high-degree heart block. Intracerebroventricular glucose infusion reduced severe hypoglycemia–induced arrhythmias and overall mortality. β-Adrenergic blockade markedly reduced cardiac arrhythmias and completely abrogated deaths due to severe hypoglycemia. Under conditions studied, sudden deaths caused by insulin-induced severe hypoglycemia were mediated by lethal cardiac arrhythmias triggered by brain neuroglycopenia and the marked sympathoadrenal response. PMID:23835337

  5. Use of bipolar radiofrequency catheter ablation in treatment of cardiac arrhythmias.

    PubMed

    Soucek, Filip; Starek, Zdenek

    2018-05-23

    Background Arrhythmia management is a complex process involving both pharmacological and non-pharmacological approaches. Radiofrequency ablation is the pillar of non-pharmacological arrhythmia treatment. Unipolar ablation is considered to be the gold standard in the treatment of the majority of arrhythmias; however, its efficacy is limited to specific cases. In particular, the creation of deep or transmural lesions to eliminate intramurally originating arrhythmias remains inadequate. Bipolar ablation is proposed as an alternative to overcome unipolar ablation boundaries. Results Despite promising results gained from in vitro and animal studies showing that bipolar ablation is superior in creating transmural lesions, the use of bipolar ablation in daily clinical practice is limited. Several studies have been published showing that bipolar ablation is effective in the treatment of clinical arrhythmias after failed unipolar ablation, however there is inconsistency regarding safety of bipolar ablation within the available research papers. According to research evidence the most common indications for bipolar ablation use are ventricular originating rhythmic disorders in patients with structural heart disease resistant to standard radiofrequency ablation. Conclusions To allow wider clinical application the efficiency and safety of bipolar ablation need to be verified in future studies. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  6. Protective effects of isorhynchophylline on cardiac arrhythmias in rats and guinea pigs.

    PubMed

    Gan, Runtao; Dong, Guo; Yu, Jiangbo; Wang, Xu; Fu, Songbin; Yang, Shusen

    2011-09-01

    As one important constituent extracted from a traditional Chinese medicine, Uncaria Rhynchophylla Miq Jacks, isorhynchophylline has been used to treat hypertension, epilepsy, headache, and other illnesses. Whether isorhynchophylline protects hearts against cardiac arrhythmias is still incompletely investigated. This study was therefore aimed to examine the preventive effects of isorhynchophylline on heart arrhythmias in guinea pigs and rats and then explore their electrophysiological mechanisms. In vivo, ouabain and calcium chloride were used to establish experimental arrhythmic models in guinea pigs and rats. In vitro, the whole-cell patch-lamp technique was used to study the effect of isorhynchophylline on action potential duration and calcium channels in acutely isolated guinea pig and rat cardiomyocytes. The dose of ouabain required to induce cardiac arrhythmias was much larger in guinea pigs administered with isorhynchophylline. Additionally, the onset time of cardiac arrhythmias induced by calcium chloride was prolonged, and the duration was shortened in rats pretreated with isorhynchophylline. The further study showed that isorhynchophylline could significantly decrease action potential duration and inhibit calcium currents in isolated guinea pig and rat cardiomyocytes in a dose-dependent manner. In summary, isorhynchophylline played a remarkably preventive role in cardiac arrhythmias through the inhibition of calcium currents in rats and guinea pigs. © Georg Thieme Verlag KG Stuttgart · New York.

  7. Sensitivity of reentrant driver localization to electrophysiological parameter variability in image-based computational models of persistent atrial fibrillation sustained by a fibrotic substrate

    NASA Astrophysics Data System (ADS)

    Deng, Dongdong; Murphy, Michael J.; Hakim, Joe B.; Franceschi, William H.; Zahid, Sohail; Pashakhanloo, Farhad; Trayanova, Natalia A.; Boyle, Patrick M.

    2017-09-01

    Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia, causing morbidity and mortality in millions worldwide. The atria of patients with persistent AF (PsAF) are characterized by the presence of extensive and distributed atrial fibrosis, which facilitates the formation of persistent reentrant drivers (RDs, i.e., spiral waves), which promote fibrillatory activity. Targeted catheter ablation of RD-harboring tissues has shown promise as a clinical treatment for PsAF, but the outcomes remain sub-par. Personalized computational modeling has been proposed as a means of non-invasively predicting optimal ablation targets in individual PsAF patients, but it remains unclear how RD localization dynamics are influenced by inter-patient variability in the spatial distribution of atrial fibrosis, action potential duration (APD), and conduction velocity (CV). Here, we conduct simulations in computational models of fibrotic atria derived from the clinical imaging of PsAF patients to characterize the sensitivity of RD locations to these three factors. We show that RDs consistently anchor to boundaries between fibrotic and non-fibrotic tissues, as delineated by late gadolinium-enhanced magnetic resonance imaging, but those changes in APD/CV can enhance or attenuate the likelihood that an RD will anchor to a specific site. These findings show that the level of uncertainty present in patient-specific atrial models reconstructed without any invasive measurements (i.e., incorporating each individual's unique distribution of fibrotic tissue from medical imaging alongside an average representation of AF-remodeled electrophysiology) is sufficiently high that a personalized ablation strategy based on targeting simulation-predicted RD trajectories alone may not produce the desired result.

  8. Optimizing catecholaminergic polymorphic ventricular tachycardia therapy in calsequestrin-mutant mice

    PubMed Central

    Katz, Guy; Khoury, Assad; Kurtzwald, Efrat; Hochhauser, Edith; Porat, Eyal; Shainberg, Asher; Seidman, Jonathan G.; Seidman, Christine E.; Lorber, Abraham; Eldar, Michael; Arad, Michael

    2014-01-01

    BACKGROUND Catecholaminergic polymorphic ventricular tachycardia (CPVT) is a lethal arrhythmia provoked by physical or emotional stress and mediated by spontaneous Ca2+ release and delayed after-depolarizations. Beta-adrenergic blockers are the therapy of choice but fail to control arrhythmia in up to 50% of patients. OBJECTIVE To optimize antiarrhythmic therapy in recessively inherited CPVT caused by calsequestrin (CASQ2) mutations. METHODS Murine heart rhythm telemetry was obtained at rest, during treadmill exercise, and after injection of epinephrine. The protocol was repeated after injection of different antiarrhythmic drugs. Results were then validated in human patients. RESULTS Adult CASQ2 mutant mice had complex ventricular arrhythmia at rest and developed bidirectional and polymorphic ventricular tachycardia on exertion. Class I antiarrhythmic agents (procainamide, lidocaine, flecainide) were ineffective in controlling arrhythmia. Propranolol and sotalol attenuated arrhythmia at rest but failed to prevent VT during sympathetic stimulation. The calcium channel blocker verapamil showed a dose-dependent protection against CPVT. Verapamil was more effective than the dihydropyridine L-type Ca2+ channel blocker nifedipine, and its activity was markedly enhanced when combined with propranolol. Human patients homozygous for CASQ2D307H mutation, remaining symptomatic despite chronic β-blocker therapy, underwent exercise testing according to the Bruce protocol with continuous electrocardiogram recording. Verapamil was combined with propranolol at maximum tolerated doses. Adding verapamil attenuated ventricular arrhythmia and prolonged exercise duration in five of 11 patients. CONCLUSION Verapamil is highly effective against catecholamine-induced arrhythmia in mice with CASQ2 mutations and may potentiate the antiarrhythmic activity of β-blockers in humans with CPVT2. PMID:20620233

  9. Carbon monoxide induces cardiac arrhythmia via induction of the late Na+ current.

    PubMed

    Dallas, Mark L; Yang, Zhaokang; Boyle, John P; Boycott, Hannah E; Scragg, Jason L; Milligan, Carol J; Elies, Jacobo; Duke, Adrian; Thireau, Jérôme; Reboul, Cyril; Richard, Sylvain; Bernus, Olivier; Steele, Derek S; Peers, Chris

    2012-10-01

    Clinical reports describe life-threatening cardiac arrhythmias after environmental exposure to carbon monoxide (CO) or accidental CO poisoning. Numerous case studies describe disruption of repolarization and prolongation of the QT interval, yet the mechanisms underlying CO-induced arrhythmias are unknown. To understand the cellular basis of CO-induced arrhythmias and to identify an effective therapeutic approach. Patch-clamp electrophysiology and confocal Ca(2+) and nitric oxide (NO) imaging in isolated ventricular myocytes was performed together with protein S-nitrosylation to investigate the effects of CO at the cellular and molecular levels, whereas telemetry was used to investigate effects of CO on electrocardiogram recordings in vivo. CO increased the sustained (late) component of the inward Na(+) current, resulting in prolongation of the action potential and the associated intracellular Ca(2+) transient. In more than 50% of myocytes these changes progressed to early after-depolarization-like arrhythmias. CO elevated NO levels in myocytes and caused S-nitrosylation of the Na(+) channel, Na(v)1.5. All proarrhythmic effects of CO were abolished by the NO synthase inhibitor l-NAME, and reversed by ranolazine, an inhibitor of the late Na(+) current. Ranolazine also corrected QT variability and arrhythmias induced by CO in vivo, as monitored by telemetry. Our data indicate that the proarrhythmic effects of CO arise from activation of NO synthase, leading to NO-mediated nitrosylation of Na(V)1.5 and to induction of the late Na(+) current. We also show that the antianginal drug ranolazine can abolish CO-induced early after-depolarizations, highlighting a novel approach to the treatment of CO-induced arrhythmias.

  10. Circadian and seasonal variation of malignant arrhythmias in a pediatric and congenital heart disease population.

    PubMed

    Stephenson, Elizabeth A; Collins, Kathryn K; Dubin, Anne M; Epstein, Michael R; Hamilton, Robert M; Kertesz, Naomi J; Alexander, Mark E; Cecchin, Frank; Triedman, John K; Walsh, Edward P; Berul, Charles I

    2002-10-01

    Recent studies in adult populations have revealed seasonal variation in the frequency of acute cardiovascular events, including life-threatening arrhythmias, demonstrating increased events during winter and early spring. Trends in the time of day that arrhythmias occur also were noted. We sought to establish whether pediatric and young adult congenital heart disease implantable cardioverter defibrillator (ICD) recipients have circadian or seasonal variability in shock frequency, similar to adult populations. Data from ICD patients at six pediatric centers in North America were analyzed to assess the timing of life-threatening arrhythmias. The populations consisted of children and adults with congenital heart disease and ICDs placed for malignant arrhythmias. Data were considered in 46 patients who received appropriate therapy (total 139 episodes) for ventricular tachycardia or ventricular fibrillation. Multiple variables were analyzed, including time of day, day of week, and month of year. In contrast to previously studied adult patients, fewer events occurred in the early morning (7.5%), with the most therapies occurring between 6 P.M. and midnight (35%). An increased frequency of therapies was observed in the fall and winter (September-January), representing 60% of all appropriate shocks. Unlike adult populations, Mondays did not have an increased frequency of malignant arrhythmias. Pediatric and adult congenital heart disease populations have moderate seasonal and 24-hour variation in ICD event rate, with some distinctly different peaks than those seen in typical adult ICD populations. These findings suggest circadian variation in arrhythmia vulnerability that may differ from conventional occupational, physical, or emotional stressors. (J Cardiovasc Electrophysiol, Vol. 13, pp.

  11. Idiopathic accelerated idioventricular rhythm or ventricular tachycardia originating from the right bundle branch: unusual type of ventricular arrhythmia.

    PubMed

    Chen, Minglong; Gu, Kai; Yang, Bing; Chen, Hongwu; Ju, Weizhu; Zhang, Fengxiang; Yang, Gang; Li, Mingfang; Lu, Xinzheng; Cao, Kejiang; Ouyang, Feifan

    2014-12-01

    Accelerated idioventricular rhythm (AIVR) or ventricular tachycardia (VT) originating from the right bundle branch (RBB) is rare and published clinical data on such arrhythmia are scarce. In this study, we will describe the clinical manifestations, diagnosis, and management of a cohort of patients with this novel arrhythmia. Eight patients (5 men; median age, 25 years) with RBB-AIVR/VT were consecutively enrolled in the study. Pharmacological testing, exercise treadmill testing, electrophysiological study, and catheter ablation were performed in the study patients, and ECG features were characterized. All RBB-AIVR/VTs were of typical left bundle-branch block morphology with atrioventricular dissociation. The arrhythmias, which demonstrated chronotropic variability, were often isorhythmic with sinus rhythm and were accelerated by physical exercise, stress, and intravenous isoprenaline infusion. The rate of RBB-AIVR/VT varied from 45 to 200 beats per minute. Two patients experienced syncope, and 3 had impaired left ventricular function. Metoprolol was proven to be the most effective drug to decelerate the arrhythmia rate and relieve symptoms. Electrophysiology study was performed in 5 patients and the earliest activation with a sharp RBB potential was localized in the mid or distal RBB area. Catheter ablation terminated the arrhythmia with subsequent RBB block morphology during sinus rhythm. During follow-up, patients' symptoms were controlled with normalization of left ventricular function either on metoprolol or by catheter ablation. RBB-AIVR/VT is an unusual type of ventricular arrhythmia. It can result in significant symptoms and depressed ventricular function and can be successfully treated with catheter ablation. © 2014 American Heart Association, Inc.

  12. Patient characteristics associated with false arrhythmia alarms in intensive care.

    PubMed

    Harris, Patricia R; Zègre-Hemsey, Jessica K; Schindler, Daniel; Bai, Yong; Pelter, Michele M; Hu, Xiao

    2017-01-01

    A high rate of false arrhythmia alarms in the intensive care unit (ICU) leads to alarm fatigue, the condition of desensitization and potentially inappropriate silencing of alarms due to frequent invalid and nonactionable alarms, often referred to as false alarms. The aim of this study was to identify patient characteristics, such as gender, age, body mass index, and diagnosis associated with frequent false arrhythmia alarms in the ICU. This descriptive, observational study prospectively enrolled patients who were consecutively admitted to one of five adult ICUs (77 beds) at an urban medical center over a period of 31 days in 2013. All monitor alarms and continuous waveforms were stored on a secure server. Nurse scientists with expertise in cardiac monitoring used a standardized protocol to annotate six clinically important types of arrhythmia alarms (asystole, pause, ventricular fibrillation, ventricular tachycardia, accelerated ventricular rhythm, and ventricular bradycardia) as true or false. Total monitoring time for each patient was measured, and the number of false alarms per hour was calculated for these six alarm types. Medical records were examined to acquire data on patient characteristics. A total of 461 unique patients (mean age =60±17 years) were enrolled, generating a total of 2,558,760 alarms, including all levels of arrhythmia, parameter, and technical alarms. There were 48,404 hours of patient monitoring time, and an average overall alarm rate of 52 alarms/hour. Investigators annotated 12,671 arrhythmia alarms; 11,345 (89.5%) were determined to be false. Two hundred and fifty patients (54%) generated at least one of the six annotated alarm types. Two patients generated 6,940 arrhythmia alarms (55%). The number of false alarms per monitored hour for patients' annotated arrhythmia alarms ranged from 0.0 to 7.7, and the duration of these false alarms per hour ranged from 0.0 to 158.8 seconds. Patient characteristics were compared in relation to 1) the number and 2) the duration of false arrhythmia alarms per 24-hour period, using nonparametric statistics to minimize the influence of outliers. Among the significant associations were the following: age ≥60 years ( P =0.013; P =0.034), confused mental status ( P <0.001 for both comparisons), cardiovascular diagnoses ( P <0.001 for both comparisons), electrocardiographic (ECG) features, such as wide ECG waveforms that correspond to ventricular depolarization known as QRS complex due to bundle branch block (BBB) ( P =0.003; P =0.004) or ventricular paced rhythm ( P =0.002 for both comparisons), respiratory diagnoses ( P =0.004 for both comparisons), and support with mechanical ventilation, including those with primary diagnoses other than respiratory ones ( P <0.001 for both comparisons). Patients likely to trigger a higher number of false arrhythmia alarms may be those with older age, confusion, cardiovascular diagnoses, and ECG features that indicate BBB or ventricular pacing, respiratory diagnoses, and mechanical ventilatory support. Algorithm improvements could focus on better noise reduction (eg, motion artifact with confused state) and distinguishing BBB and paced rhythms from ventricular arrhythmias. Increasing awareness of patient conditions that apparently trigger a higher rate of false arrhythmia alarms may be useful for reducing unnecessary noise and improving alarm management.

  13. Arrhythmias

    MedlinePlus

    ... sign of other heart problems, or an immediate danger to your health. ... patient with suspected arrhythmia. In: Goldman L, Schafer AI, eds. Goldman’s Cecil Medicine . 25th ed. Philadelphia, PA: ...

  14. Double hazards of ischemia and reperfusion arrhythmias in a patient with variant angina pectoris.

    PubMed

    Xu, Mingzhu; Yang, Xiangjun

    2015-01-01

    Variant angina pectoris, also called Prinzmetal's angina, is a syndrome caused by vasospasms of the coronary arteries. It can lead to myocardial infarction, ventricular arrhythmias, atrioventricular block and even sudden cardiac death. We report the case of a 53 year-old male patient with recurrent episodes of chest pain and arrhythmias in the course of related variant angina pectoris. It is likely that the reperfusion following myocardial ischemia was responsible for the ventricular fibrillation while the ST-segment returned to the baseline. This case showed that potential lethal arrhythmias could arise due to variant angina pectoris. It also indicated that ventricular fibrillation could be self-terminated. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. Evaluation of a New Shirt-Based Electrocardiogram Device for Cardiac Screening in Soccer Players: Comparative Study With Treadmill Ergospirometry.

    PubMed

    Fabregat-Andres, Oscar; Munoz-Macho, Adolfo; Adell-Beltran, Guillermo; Ibanez-Catala, Xavier; Macia, Agustin; Facila, Lorenzo

    2014-08-01

    Prevention of cardiac events during competitive sports is fundamental. New technologies with remote monitoring systems integrated into clothing could facilitate the screening of heart disease. Our aim was to evaluate the feasibility of Nuubo system during a field stress test performed by soccer players, comparing results with treadmill ergospirometry as test reference. Nineteen male professional soccer players (19.2 ± 1.6 years) were studied. Wireless electrocardiographic monitoring during a Yo-Yo intermittent recovery test level 1 in soccer field and subsequent analysis of arrhythmias were firstly performed. Subsequently, in a period no longer than 4 weeks, each player underwent cardiopulmonary exercise testing in hospital. During Yo-Yo test, electrocardiogram (ECG) signal was interpretable in 16 players (84.2%). In the other three players, ECG artifacts did not allow a proper analysis. Estimation of maximum oxygen consumption was comparable between two exercise tests (VO 2 max 53.3 ± 2.4 vs. 53.7 ± 3.0 mL/kg/min for Yo-Yo test and ergometry respectively; intra-class correlation coefficient 0.84 (0.63 - 0.93), P < 0.001). No arrhythmias were detected in any player during both tests. The use of Nuubo's technology allows an accurate single-lead electrocardiographic recording and estimation of reliable performance variables during exercise testing in field, and provides a new perspective to cardiac remote monitoring in collective sports.

  16. Semiautomatic segmentation of the heart from CT images based on intensity and morphological features

    NASA Astrophysics Data System (ADS)

    Redwood, Abena B.; Camp, Jon J.; Robb, Richard A.

    2005-04-01

    The incidence of certain types of cardiac arrhythmias is increasing. Effective, minimally invasive treatment has remained elusive. Pharmacologic treatment has been limited by drug intolerance and recurrence of disease. Catheter based ablation has been moderately successful in treating certain types of cardiac arrhythmias, including typical atrial flutter and fibrillation, but there remains a relatively high rate of recurrence. Additional side effects associated with cardiac ablation procedures include stroke, perivascular lung damage, and skin burns caused by x-ray fluoroscopy. Access to patient specific 3-D cardiac images has potential to significantly improve the process of cardiac ablation by providing the physician with a volume visualization of the heart. This would facilitate more effective guidance of the catheter, increase the accuracy of the ablative process, and eliminate or minimize the damage to surrounding tissue. In this study, a semiautomatic method for faithful cardiac segmentation was investigated using Analyze - a comprehensive processing software package developed at the Biomedical Imaging Resource, Mayo Clinic. This method included use of interactive segmentation based on math morphology and separation of the chambers based on morphological connections. The external surfaces of the hearts were readily segmented, while accurate separation of individual chambers was a challenge. Nonetheless, a skilled operator could manage the task in a few minutes. Useful improvements suggested in this paper would give this method a promising future.

  17. Nadolol decreases the incidence and severity of ventricular arrhythmias during exercise stress testing compared with β1-selective β-blockers in patients with catecholaminergic polymorphic ventricular tachycardia.

    PubMed

    Leren, Ida S; Saberniak, Jørg; Majid, Eman; Haland, Trine F; Edvardsen, Thor; Haugaa, Kristina H

    2016-02-01

    Catecholaminergic polymorphic ventricular tachycardia (CPVT) is an inheritable cardiac disease predisposing to malignant ventricular arrhythmias. We aimed to explore the incidence and severity of ventricular arrhythmias in patients with CPVT before the initiation of β-blocker treatment, when treated with β1-selective β-blockers, and when treated with nadolol. In this study, 34 patients with CPVT were included (mean age 34 ± 19 years; 15 (44%) women; 30 (88%) ryanodine receptor 2 variant positive). We performed 3 bicycle exercise stress tests in each patient: (1) before the initiation of β-blocker treatment, (2) after >6 weeks of treatment with β1-selective β-blockers and (3) after >6 weeks of treatment with nadolol. We recorded resting and maximum heart rates and the most severe ventricular arrhythmia occurring. Severity of arrhythmias was scored as 1 point for no arrhythmias or only single ventricular extrasystoles, 2 points for >10 ventricular extrasystoles per minute or bigeminy, 3 points for couplets, and 4 points for nonsustained ventricular tachycardia or sustained ventricular tachycardia. Resting heart rate was similar during treatment with nadolol and β1-selective β-blockers (54 ± 10 beats/min vs 56 ± 14 beats/min; P = .50), while maximum heart rate was lower during treatment with nadolol compared with β1-selective β-blockers (122 ± 21 beats/min vs 139 ± 24 beats/min; P = .001). Arrhythmias during exercise stress testing were less severe during treatment with nadolol compared with during treatment with β1-selective β-blockers (arrhythmic score 1.6 ± 0.9 vs 2.5 ± 0.8; P < .001) and before the initiation of β-blocker treatment (arrhythmic score 1.6 ± 0.9 vs 2.7 ± 0.9; P = .001); however, no differences were observed during treatment with β1-selective β-blockers compared with before the initiation of β-blocker treatment (arrhythmic score 2.5 ± 0.8 vs 2.7 ± 0.9; P = .46). The incidence and severity of ventricular arrhythmias decreased during treatment with nadolol compared with during treatment with β1-selective β-blockers. β1-Selective β-blockers did not change the occurrence or severity of arrhythmias compared with no medication. Copyright © 2016 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  18. Hypertension and cardiac arrhythmias: executive summary of a consensus document from the European Heart Rhythm Association (EHRA) and ESC Council on Hypertension, endorsed by the Heart Rhythm Society (HRS), Asia-Pacific Heart Rhythm Society (APHRS), and Sociedad Latinoamericana de Estimulación Cardíaca y Electrofisiología (SOLEACE).

    PubMed

    Lip, Gregory Y H; Coca, Antonio; Kahan, Thomas; Boriani, Giuseppe; Manolis, Antonis S; Olsen, Michael Hecht; Oto, Ali; Potpara, Tatjana S; Steffel, Jan; Marín, Francisco; de Oliveira Figueiredo, Márcio Jansen; de Simone, Giovanni; Tzou, Wendy S; En Chiang, Chern; Williams, Bryan

    2017-10-01

    Hypertension (HTN) is a common cardiovascular risk factor leading to heart failure (HF), coronary artery disease (CAD), stroke, peripheral artery disease and chronic renal failure. Hypertensive heart disease can manifest as many types of cardiac arrhythmias, most commonly being atrial fibrillation (AF). Both supraventricular and ventricular arrhythmias may occur in HTN patients, especially in those with left ventricular hypertrophy (LVH), CAD, or HF. In addition, high doses of thiazide diuretics commonly used to treat HTN, may result in electrolyte abnormalities (e.g. hypokalaemia, hypomagnesaemia), contributing further to arrhythmias, while effective blood pressure control may prevent the development of the arrhythmias such as AF. In recognizing this close relationship between HTN and arrhythmias, the European Heart Rhythm Association (EHRA) and the European Society of Cardiology (ESC) Council on Hypertension convened a Task Force, with representation from the Heart Rhythm Society (HRS), Asia-Pacific Heart Rhythm Society (APHRS), and Sociedad Latinoamericana de Estimulación Cardíaca y Electrofisiología (SOLEACE), with the remit of comprehensively reviewing the available evidence and publishing a joint consensus document on HTN and cardiac arrhythmias, and providing up-to-date consensus recommendations for use in clinical practice. The ultimate judgment on the care of a specific patient must be made by the healthcare provider and the patient in light of all individual factors presented. This is an executive summary of the full document co-published by EHRA in EP-Europace. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For Permissions, please email: journals.permissions@oup.com.

  19. Hypertension and cardiac arrhythmias: a consensus document from the European Heart Rhythm Association (EHRA) and ESC Council on Hypertension, endorsed by the Heart Rhythm Society (HRS), Asia-Pacific Heart Rhythm Society (APHRS) and Sociedad Latinoamericana de Estimulación Cardíaca y Electrofisiología (SOLEACE).

    PubMed

    Lip, Gregory Y H; Coca, Antonio; Kahan, Thomas; Boriani, Giuseppe; Manolis, Antonis S; Olsen, Michael Hecht; Oto, Ali; Potpara, Tatjana S; Steffel, Jan; Marín, Francisco; de Oliveira Figueiredo, Márcio Jansen; de Simone, Giovanni; Tzou, Wendy S; Chiang, Chern-En; Williams, Bryan; Dan, Gheorghe-Andrei; Gorenek, Bulent; Fauchier, Laurent; Savelieva, Irina; Hatala, Robert; van Gelder, Isabelle; Brguljan-Hitij, Jana; Erdine, Serap; Lovic, Dragan; Kim, Young-Hoon; Salinas-Arce, Jorge; Field, Michael

    2017-06-01

    Hypertension is a common cardiovascular risk factor leading to heart failure (HF), coronary artery disease, stroke, peripheral artery disease and chronic renal insufficiency. Hypertensive heart disease can manifest as many cardiac arrhythmias, most commonly being atrial fibrillation (AF). Both supraventricular and ventricular arrhythmias may occur in hypertensive patients, especially in those with left ventricular hypertrophy (LVH) or HF. Also, some of the antihypertensive drugs commonly used to reduce blood pressure, such as thiazide diuretics, may result in electrolyte abnormalities (e.g. hypokalaemia, hypomagnesemia), further contributing to arrhythmias, whereas effective control of blood pressure may prevent the development of the arrhythmias such as AF. In recognizing this close relationship between hypertension and arrhythmias, the European Heart Rhythm Association (EHRA) and the European Society of Cardiology (ESC) Council on Hypertension convened a Task Force, with representation from the Heart Rhythm Society (HRS), Asia-Pacific Heart Rhythm Society (APHRS), and Sociedad Latinoamericana de Estimulación Cardíaca y Electrofisiología (SOLEACE), with the remit to comprehensively review the available evidence to publish a joint consensus document on hypertension and cardiac arrhythmias, and to provide up-to-date consensus recommendations for use in clinical practice. The ultimate judgment regarding care of a particular patient must be made by the healthcare provider and the patient in light of all of the circumstances presented by that patient. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.

  20. Dual chamber arrhythmia detection in the implantable cardioverter defibrillator.

    PubMed

    Dijkman, B; Wellens, H J

    2000-10-01

    Dual chamber implantable cardioverter defibrillator (ICD) technology extended ICD therapy to more than termination of hemodynamically unstable ventricular tachyarrhythmias. It created the basis for dual chamber arrhythmia management in which dependable detection is important for treatment and prevention of both ventricular and atrial arrhythmias. Dual chamber detection algorithms were investigated in two Medtronic dual chamber ICDs: the 7250 Jewel AF (33 patients) and the 7271 Gem DR (31 patients). Both ICDs use the same PR Logic algorithm to interpret tachycardia as ventricular tachycardia (VT), supraventricular tachycardia (SVT), or dual (VT+ SVT). The accuracy of dual chamber detection was studied in 310 of 1,367 spontaneously occurring tachycardias in which rate criterion only was not sufficient for arrhythmia diagnosis. In 78 episodes there was a double tachycardia, in 223 episodes SVT was detected in the VT or ventricular fibrillation zone, and in 9 episodes arrhythmia was detected outside the boundaries of the PR Logic functioning. In 100% of double tachycardias the VT was correctly diagnosed and received priority treatment. SVT was seen in 59 (19%) episodes diagnosed as VT. The causes of inappropriate detection were (1) algorithm failure (inability to fulfill the PR

  1. Risk of Ventricular Arrhythmia with Citalopram and Escitalopram: A Population-Based Study.

    PubMed

    Qirjazi, Elena; McArthur, Eric; Nash, Danielle M; Dixon, Stephanie N; Weir, Matthew A; Vasudev, Akshya; Jandoc, Racquel; Gula, Lorne J; Oliver, Matthew J; Wald, Ron; Garg, Amit X

    2016-01-01

    The risk of ventricular arrhythmia with citalopram and escitalopram is controversial. In this study we investigated the association between these two drugs and the risk of ventricular arrhythmia. We conducted a population-based retrospective cohort study of older adults (mean age 76 years) from 2002 to 2012 in Ontario, Canada, newly prescribed citalopram (n = 137 701) or escitalopram (n = 38 436), compared to those prescribed referent antidepressants sertraline or paroxetine (n = 96 620). After inverse probability of treatment weighting using a propensity score, the baseline characteristics of the comparison groups were similar. The primary outcome was a hospital encounter with ventricular arrhythmia within 90 days of a new prescription, assessed using hospital diagnostic codes. The secondary outcome was all-cause mortality within 90 days. Citalopram was associated with a higher risk of a hospital encounter with ventricular arrhythmia compared with referent antidepressants (0.06% vs. 0.04%, relative risk [RR] 1.53, 95% confidence intervals [CI]1.03 to 2.29), and a higher risk of mortality (3.49% vs. 3.12%, RR 1.12, 95% CI 1.06 to 1.18). Escitalopram was not associated with a higher risk of ventricular arrhythmia compared with the referent antidepressants (0.03% vs. 0.04%, RR 0.84, 95% CI 0.42 to 1.68), but was associated with a higher risk of mortality (2.86% vs. 2.63%, RR 1.09, 95% CI 1.01 to 1.18). Among older adults, initiation of citalopram compared to two referent antidepressants was associated with a small but statistically significant increase in the 90-day risk of a hospital encounter for ventricular arrhythmia.

  2. Risk of Ventricular Arrhythmia with Citalopram and Escitalopram: A Population-Based Study

    PubMed Central

    Qirjazi, Elena; McArthur, Eric; Nash, Danielle M.; Dixon, Stephanie N.; Weir, Matthew A.; Vasudev, Akshya; Jandoc, Racquel; Gula, Lorne J.; Oliver, Matthew J.; Wald, Ron; Garg, Amit X.

    2016-01-01

    Background The risk of ventricular arrhythmia with citalopram and escitalopram is controversial. In this study we investigated the association between these two drugs and the risk of ventricular arrhythmia. Methods We conducted a population-based retrospective cohort study of older adults (mean age 76 years) from 2002 to 2012 in Ontario, Canada, newly prescribed citalopram (n = 137 701) or escitalopram (n = 38 436), compared to those prescribed referent antidepressants sertraline or paroxetine (n = 96 620). After inverse probability of treatment weighting using a propensity score, the baseline characteristics of the comparison groups were similar. The primary outcome was a hospital encounter with ventricular arrhythmia within 90 days of a new prescription, assessed using hospital diagnostic codes. The secondary outcome was all-cause mortality within 90 days. Results Citalopram was associated with a higher risk of a hospital encounter with ventricular arrhythmia compared with referent antidepressants (0.06% vs. 0.04%, relative risk [RR] 1.53, 95% confidence intervals [CI]1.03 to 2.29), and a higher risk of mortality (3.49% vs. 3.12%, RR 1.12, 95% CI 1.06 to 1.18). Escitalopram was not associated with a higher risk of ventricular arrhythmia compared with the referent antidepressants (0.03% vs. 0.04%, RR 0.84, 95% CI 0.42 to 1.68), but was associated with a higher risk of mortality (2.86% vs. 2.63%, RR 1.09, 95% CI 1.01 to 1.18). Conclusion Among older adults, initiation of citalopram compared to two referent antidepressants was associated with a small but statistically significant increase in the 90-day risk of a hospital encounter for ventricular arrhythmia. PMID:27513855

  3. Remodeling of atrial ATP-sensitive K+ channels in a model of salt-induced elevated blood pressure

    PubMed Central

    Lader, Joshua M.; Vasquez, Carolina; Bao, Li; Maass, Karen; Qu, Jiaxiang; Kefalogianni, Eirini; Fishman, Glenn I.; Coetzee, William A.

    2011-01-01

    Hypertension is associated with the development of atrial fibrillation; however, the electrophysiological consequences of this condition remain poorly understood. ATP-sensitive K+ (KATP) channels, which contribute to ventricular arrhythmias, are also expressed in the atria. We hypothesized that salt-induced elevated blood pressure (BP) leads to atrial KATP channel activation and increased arrhythmia inducibility. Elevated BP was induced in mice with a high-salt diet (HS) for 4 wk. High-resolution optical mapping was used to measure atrial arrhythmia inducibility, effective refractory period (ERP), and action potential duration at 90% repolarization (APD90). Excised patch clamping was performed to quantify KATP channel properties and density. KATP channel protein expression was also evaluated. Atrial arrhythmia inducibility was 22% higher in HS hearts compared with control hearts. ERP and APD90 were significantly shorter in the right atrial appendage and left atrial appendage of HS hearts compared with control hearts. Perfusion with 1 μM glibenclamide or 300 μM tolbutamide significantly decreased arrhythmia inducibility and prolonged APD90 in HS hearts compared with untreated HS hearts. KATP channel density was 156% higher in myocytes isolated from HS animals compared with control animals. Sulfonylurea receptor 1 protein expression was increased in the left atrial appendage and right atrial appendage of HS animals (415% and 372% of NS animals, respectively). In conclusion, KATP channel activation provides a mechanistic link between salt-induced elevated BP and increased atrial arrhythmia inducibility. The findings of this study have important implications for the treatment and prevention of atrial arrhythmias in the setting of hypertensive heart disease and may lead to new therapeutic approaches. PMID:21724863

  4. Respiratory sinus arrhythmia is a limited measure of cardiac parasympathetic control in man.

    PubMed Central

    Kollai, M; Mizsei, G

    1990-01-01

    1. Respiratory modulation of cardiac parasympathetic activity and the relationship between respiratory sinus arrhythmia and parasympathetic control has been studied in twenty-nine conscious, healthy young adult subjects. 2. Changes in heart period in propranolol-treated subjects were taken as the measure of changes in cardiac parasympathetic activity; respiratory sinus arrhythmia was quantified as the difference between maximum and minimum heart periods in a given respiratory cycle; cardiac parasympathetic control was defined as the change in heart period after administration of a full dose of atropine. 3. During normal quiet breathing the inspiratory level of cardiac parasympathetic activity was not reduced to zero. The expiratory level was influenced by excitatory inputs whose activation was related to respiratory cycle length. 4. Slow breathing was associated with augmented sinus arrhythmia, but in different individuals the influence on minimum and maximum heart periods varied so that mean heart period was increased in some subjects but decreased in others. This occurred both in control conditions and after administration of a full dose of propranolol. 5. During normal breathing the correlation across subjects between respiratory sinus arrhythmia and parasympathetic control, although significant, was not close (r = 0.61). The relationship was not affected by beta-adrenergic blockade (r = 0.63). The strength of the correlation improved when multiple regression of respiratory sinus arrhythmia was performed on three variables: parasympathetic control, respiratory cycle length and tidal volume (R = 0.93). 6. It is concluded that in conscious human subjects the respiratory modulation of cardiac parasympathetic activity is different from that observed in the anaesthetized dog, and that variations in the amplitude of respiratory sinus arrhythmia do not necessarily reflect proportional changes in cardiac parasympathetic control. PMID:2391653

  5. [Intravenous nitroglycerin infusion suppresses exercise-induced arrhythmia in patients with ischemic cardiopathy: indications for chronic treatment ].

    PubMed

    Bonetti, F; Margonato, A; Mailhac, A; Vicedomini, G; Cianflone, D; Scarpazza, P; Chierchia, S L

    1990-05-01

    In patients with ischemic heart disease and arrhythmias, selection of antiarrhythmic treatment is often difficult as it is hard to separate "primary" from ischemic arrhythmias. We studied 20 patients with ischemic heart disease, who developed ventricular arrhythmias consistently during exercise test. Exercise test was performed twice during infusion of placebo and then during intravenous administration of nitroglycerin, titrated to reduce systolic blood pressure by 10 mmHg. Exercise duration was 7.8 +/- 1.7 and 7.9 +/- 1.5 min, in the 2 placebo tests (NS). Angina developed in 5 patients and ischemic ST changes in 10. With nitroglycerin exercise duration increased to 8.4 +/- 20 min (p less than 0.05), diagnostic ST segment depression was observed in 2 patients and only 1 had angina. In all 20 patients, ventricular arrhythmias were consistently present during both tests on placebo, that were markedly reduced by nitroglycerin. In fact, ventricular ectopic beats were 455 (mean 35.8 +/- 16.8) and 418 (mean 34.4 +/- 11.1) in the 2 exercise tests with placebo, and 11 during nitroglycerin infusion (mean 0.6 +/- 0.1; p less than 0.001). Couplets were 28 and 29 during placebo (NS) and 0 during nitroglycerin (p less than 0.001). Ventricular tachycardia was present in 6 and 8 patients during placebo but in none during nitroglycerin (p less than 0.001). Reduction of exercise-induced arrhythmias was maintained during chronic treatment with oral vasodilators. Prevention of exercise-related arrhythmias by nitroglycerin infusion appears a good indicator of their ischemic origin and may provide valuable information for long-term profilaxis with oral vasodilators, then avoiding the use of antiarrhythmic agents and their potential side effects.

  6. Catheter radiofrequency ablation for arrhythmias under the guidance of the Carto 3 three-dimensional mapping system in an operating room without digital subtraction angiography.

    PubMed

    Huang, Xingfu; Chen, Yanjia; Huang, Zheng; He, Liwei; Liu, Shenrong; Deng, Xiaojiang; Wang, Yongsheng; Li, Rucheng; Xu, Dingli; Peng, Jian

    2018-06-01

    Several studies have reported the efficacy of a zero-fluoroscopy approach for catheter radiofrequency ablation of arrhythmias in a digital subtraction angiography (DSA) room. However, no reports are available on the ablation of arrhythmias in the absence of DSA in the operating room. To investigate the efficacy and safety of catheter radiofrequency ablation for arrhythmias under the guidance of a Carto 3 three-dimensional (3D) mapping system in an operating room without DSA. Patients were enrolled according to the type of arrhythmia. The Carto 3 mapping system was used to reconstruct heart models and guide the electrophysiologic examination, mapping, and ablation. The total procedure, reconstruction, electrophysiologic examination, and mapping times were recorded. Furthermore, immediate success rates and complications were also recorded. A total of 20 patients were enrolled, including 12 males. The average age was 51.3 ± 17.2 (19-76) years. Nine cases of atrioventricular nodal re-entrant tachycardia, 7 cases of frequent ventricular premature contractions, 3 cases of Wolff-Parkinson-White syndrome, and 1 case of typical atrial flutter were included. All arrhythmias were successfully ablated. The procedure time was 127.0 ± 21.0 (99-177) minutes, the reconstruction time was 6.5 ± 2.9 (3-14) minutes, the electrophysiologic study time was 10.4 ± 3.4 (6-20) minutes, and the mapping time was 11.7 ± 8.3 (3-36) minutes. No complications occurred. Radiofrequency ablation of arrhythmias without DSA is effective and feasible under the guidance of the Carto 3 mapping system. However, the electrophysiology physician must have sufficient experience, and related emergency measures must be present to ensure safety.

  7. [Kurschmann-Steinert myotonic dystrophia and Adams-Stoke attacks. Successful treatment of arrhythmia by means of pacemaker implantation].

    PubMed

    Bieler, M; Sefidpar, M; Engel, U R; Reutter, F W

    1976-11-20

    The case is reported of a 39-year-old male with Steinert's dystrophia myotonica complicated by cardiac arrhythmias manifested by high-degree a-v block with Stokes-Adams attacks. Implantation of a demand-type cardiac pacemaker brought prompt relief from cardiac symptoms and the patient was able to resume work. The pathologico-anatomical findings in dystrophia myotonica are discussed, together with their possible connection with the type of arrhythmias described.

  8. Electrical alternans during rest and exercise as predictors of vulnerability to ventricular arrhythmias

    NASA Technical Reports Server (NTRS)

    Estes, N. A. 3rd; Michaud, G.; Zipes, D. P.; El-Sherif, N.; Venditti, F. J.; Rosenbaum, D. S.; Albrecht, P.; Wang, P. J.; Cohen, R. J.

    1997-01-01

    This investigation was performed to evaluate the feasibility of detecting repolarization alternans with the heart rate elevated with a bicycle exercise protocol. Sensitive spectral signal-processing techniques are able to detect beat-to-beat alternation of the amplitude of the T wave, which is not visible on standard electrocardiogram. Previous animal and human investigations using atrial or ventricular pacing have demonstrated that T-wave alternans is a marker of vulnerability to ventricular arrhythmias. Using a spectral analysis technique incorporating noise reduction signal-processing software, we evaluated electrical alternans at rest and with the heart rate elevated during a bicycle exercise protocol. In this study we defined optimal criteria for electrical alternans to separate patients from those without inducible arrhythmias. Alternans and signal-averaged electrocardiographic results were compared with the results of vulnerability to ventricular arrhythmias as defined by induction of sustained ventricular tachycardia or fibrillation at electrophysiologic evaluation. In 27 patients alternans recorded at rest and with exercise had a sensitivity of 89%, specificity of 75%, and overall clinical accuracy of 80% (p <0.003). In this patient population the signal-averaged electrocardiogram was not a significant predictor of arrhythmia vulnerability. This is the first study to report that repolarization alternans can be detected with heart rate elevated with a bicycle exercise protocol. Alternans measured using this technique is an accurate predictor of arrhythmia inducibility.

  9. Cardiac conduction disturbance after loperamide abuse.

    PubMed

    Marraffa, J M; Holland, M G; Sullivan, R W; Morgan, B W; Oakes, J A; Wiegand, T J; Hodgman, M J

    2014-11-01

    Prescription opioid abuse is a major public health concern and an ongoing epidemic in the United States. Loperamide is a widely available and inexpensive over-the-counter antidiarrheal with peripheral mu-opioid receptor activity. Online resources discuss the use of loperamide for the amelioration of withdrawal symptoms or recreational abuse. We describe the clinical course of 5 patients abusing loperamide, 3 of whom had life-threatening cardiac arrhythmias. In this observational case series, patients with cardiac arrhythmias or history of loperamide abuse with cardiac arrhythmias were identified; 5 patients were identified and 4 of the 5 patients were seen directly at the bedside. Clinical profile and outcome of patients is reported. We report 5 patients with history of loperamide abuse; 3 of the 5 patients had life-threatening cardiac arrhythmias. One of the patients experienced a second life-threatening arrhythmia after he resumed loperamide abuse. Loperamide levels were obtained in 4 of the 5 patients and were at least one order of magnitude greater than therapeutic concentrations. Discontinuation of loperamide resulted in complete resolution of cardiac conduction disturbances. This case series describes several patients with cardiac conduction abnormalities and life-threatening ventricular arrhythmias temporally related to loperamide abuse. With the recent efforts to restrict the diversion of prescription opioids, increasing abuse of loperamide as an opioid substitute may be seen. Toxicologists should be aware of these risks and we urge all clinicians to report such cases to FDA Medwatch(®).

  10. Management of Arrhythmias in Heart Failure

    PubMed Central

    Masarone, Daniele; Limongelli, Giuseppe; Rubino, Marta; Valente, Fabio; Vastarella, Rossella; Ammendola, Ernesto; Gravino, Rita; Verrengia, Marina; Salerno, Gemma; Pacileo, Giuseppe

    2017-01-01

    Heart failure patients are predisposed to develop arrhythmias. Supraventricular arrhythmias can exacerbate the heart failure symptoms by decreasing the effective cardiac output and their control require pharmacological, electrical, or catheter-based intervention. In the setting of atrial flutter or atrial fibrillation, anticoagulation becomes paramount to prevent systemic or cerebral embolism. Patients with heart failure are also prone to develop ventricular arrhythmias that can present a challenge to the managing clinician. The management strategy depends on the type of arrhythmia, the underlying structural heart disease, the severity of heart failure, and the range from optimization of heart failure therapy to catheter ablation. Patients with heart failure, irrespective of ejection fraction are at high risk for developing sudden cardiac death, however risk stratification is a clinical challenge and requires a multiparametric evaluation for identification of patients who should undergo implantation of a cardioverter defibrillator. Finally, patients with heart failure can also develop symptomatic bradycardia, caused by sinus node dysfunction or atrio-ventricular block. The treatment of bradycardia in these patients with pacing is usually straightforward but needs some specific issue. PMID:29367535

  11. Cardiac Arrhythmia Classification by Multi-Layer Perceptron and Convolution Neural Networks.

    PubMed

    Savalia, Shalin; Emamian, Vahid

    2018-05-04

    The electrocardiogram (ECG) plays an imperative role in the medical field, as it records heart signal over time and is used to discover numerous cardiovascular diseases. If a documented ECG signal has a certain irregularity in its predefined features, this is called arrhythmia, the types of which include tachycardia, bradycardia, supraventricular arrhythmias, and ventricular, etc. This has encouraged us to do research that consists of distinguishing between several arrhythmias by using deep neural network algorithms such as multi-layer perceptron (MLP) and convolution neural network (CNN). The TensorFlow library that was established by Google for deep learning and machine learning is used in python to acquire the algorithms proposed here. The ECG databases accessible at PhysioBank.com and kaggle.com were used for training, testing, and validation of the MLP and CNN algorithms. The proposed algorithm consists of four hidden layers with weights, biases in MLP, and four-layer convolution neural networks which map ECG samples to the different classes of arrhythmia. The accuracy of the algorithm surpasses the performance of the current algorithms that have been developed by other cardiologists in both sensitivity and precision.

  12. Emerging molecular therapies targeting myocardial infarction-related arrhythmias.

    PubMed

    Driessen, Helen E; van Veen, Toon A B; Boink, Gerard J J

    2017-04-01

    Cardiac disease is the leading cause of death in the developed world. Ventricular arrhythmias associated with myocardial ischaemia and/or infarction are a major contributor to cardiovascular mortality, and require improved prevention and treatment. Drugs, devices, and radiofrequency catheter ablation have made important inroads, but have significant limitations ranging from incomplete success to undesired toxicities and major side effects. These limitations derive from the nature of the intervention. Drugs are frequently ineffective, target the entire heart, and often do not deal with the specific arrhythmia trigger or substrate. Devices can terminate rapid rhythms but at best indirectly affect the underlying disease, while ablation, even when appropriately targeted, induces additional tissue damage. In contrast, exploration of gene and cell therapies are expected to provide a targeted, non-destructive, and potentially regenerative approach to ischaemia- and infarction-related arrhythmias. Although these approaches are in the early stages of development, they carry substantial potential to advance arrhythmia prevention and treatment. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  13. Mechanisms of arrhythmogenesis related to calcium-driven alternans in a model of human atrial fibrillation

    NASA Astrophysics Data System (ADS)

    Chang, Kelly C.; Trayanova, Natalia A.

    2016-11-01

    The occurrence of atrial fibrillation (AF) is associated with progressive changes in the calcium handling system of atrial myocytes. Calcium cycling instability has been implicated as an underlying mechanism of electrical alternans observed in patients who experience AF. However, the extent to which calcium-induced alternation of electrical activity in the atria contributes to arrhythmogenesis is unknown. In this study, we investigated the effects of calcium-driven alternans (CDA) on arrhythmia susceptibility in a biophysically detailed, 3D computer model of the human atria representing electrical and structural remodeling secondary to chronic AF. We found that elevated propensity to CDA rendered the atria vulnerable to ectopy-induced arrhythmia. It also increased the complexity and persistence of arrhythmias induced by fast pacing, with unstable scroll waves meandering and frequently breaking up to produce multiple wavelets. Our results suggest that calcium-induced electrical instability may increase arrhythmia vulnerability and promote increasing disorganization of arrhythmias in the chronic AF-remodeled atria, thus playing an important role in the progression of the disease.

  14. Arrhythmia discrimination by physician and defibrillator: importance of atrial channel.

    PubMed

    Diemberger, Igor; Martignani, Cristian; Biffi, Mauro; Frabetti, Lorenzo; Valzania, Cinzia; Cooke, Robin M T; Rapezzi, Claudio; Branzi, Angelo; Boriani, Giuseppe

    2012-01-26

    Many ICD carriers experience inappropriate shocks, but the relative merits of dual- /single-chamber devices for arrhythmia discrimination still remain unclear. We explored possible advantages of the atrial data provided by dual-chamber implantable defibrillators (ICD) for discrimination of real-life supraventricular/ventricular tachyarrhythmias (SVT/VT). 100 dual-chamber traces from 24 ICD were blindly reviewed in dual-chamber and simulated single-chamber (with/without discriminator data) reading modes by five electrophysiologists who determined chamber of origin and provided Likert-scale "confidence" ratings. We assessed 1) intra/interobserver concordance; 2) diagnostic accuracy, using expert diagnoses as a reference standard; 3) ROC curves of sensitivity/specificity of "likelihood perception" scores, generated by combining chamber-of-origin diagnostic judgments with Likert-scale "confidence" ratings. We also assessed diagnostic accuracy of automated discrimination by all possible dual-/single-chamber algorithm configurations. Interobserver concordance was "substantial" (modified Cohen kappa-test values for dual-/single-chamber, 0.79/0.68); intraobserver concordance "almost complete" (kappa ≥ 0.89). Dual-chamber mode provided best diagnostic sensitivity/specificity (99%/92%) and highest reader confidence (p<0.001). Area under ROC curves of sensitivity/specificity values for the "likelihood perception" score (representing electrophysiologists' perceptions of the likelihood that an episode was of ventricular origin) was highest in dual-chamber mode (0.98 vs. 0.93 for both single-chamber modes; p<0.001). Regarding automated discrimination, all four dual-chamber configurations conferred 100% sensitivity (specificity values ranged 39%-88%), whereas single-chamber configurations appeared inferior (best sensitivity/specificity combination, 89%/64%). Availability of the atrial channel helps in reducing inappropriate ICD therapies by providing relevant advantages in terms of both appropriate cardiologist's post-hoc discrimination of SVT/VT (improving program tailoring) and automated arrhythmia discrimination. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  15. A benefit-risk assessment of class III antiarrhythmic agents.

    PubMed

    Brendorp, Bente; Pedersen, Oledyg; Torp-Pedersen, Christian; Sahebzadah, Naji; Køber, Lars

    2002-01-01

    With beta-blockers as the exception, increasing doubt is emerging on the value of antiarrhythmic drug therapy following a series of trials that have either shown no mortality benefit or even an excess mortality. Vaughan Williams class I drugs are generally avoided in patients with structural heart disease, and class IV drugs are avoided in heart failure. Unfortunately, arrhythmias are a growing problem due to an increase in the incidence of atrial fibrillation and sudden death. The population is becoming older and more patients survive for a longer time period with congestive heart failure, which again increases the frequency of both supraventricular as well as ventricular arrhythmias. Class III antiarrhythmic drugs act by blocking repolarising currents and thereby prolong the effective refractory period of the myocardium. This is believed to facilitate termination of re-entry tachyarrhythmias. This class of drugs is developed for treatment of both supraventricular and ventricular arrhythmias. Amiodarone, sotalol, dofetilide, and ibutilide are examples of class III drugs that are currently available. Amiodarone and sotalol have other antiarrhythmic properties in addition to pure class III action, which differentiates them from the others. However, all have potential serious adverse events. Proarrhythmia, especially torsade de pointes, is a common problem making the benefit-risk ratio of these drugs a key question. Class III drugs have been evaluated in different settings: primary and secondary prevention of ventricular arrhythmias and in treatment of atrial fibrillation or flutter. Based on existing evidence there is no routine indication for antiarrhythmic drug therapy other than beta-blockers in patients at high risk of sudden death. Subgroup analyses of trials with amiodarone and dofetilide suggest that patients with atrial fibrillation may have a mortality reduction with these drugs. However, this needs to be tested in a prospective trial. Similarly, subgroups that will benefit from prophylactic treatment with class III antiarrhythmic drugs may be found based on QT-intervals or - in the future - from genetic testing. Class III drugs are effective in converting atrial fibrillation to sinus rhythm and for the maintenance of sinus rhythm after conversion. This is currently by far the most important indication for this class of drugs. As defined by recent guidelines, amiodarone and dofetilide have their place as second-line therapy except for patients with heart failure where they are first line therapy being the only drugs where the safety has been documented for this group of high risk patients.

  16. Method and apparatus for the guided ablative therapy of fast ventricular arrhythmia

    NASA Technical Reports Server (NTRS)

    Cohen, Richard J. (Inventor); Barley, Maya (Inventor)

    2010-01-01

    Method and apparatus for guiding ablative therapy of abnormal biological electrical excitation. The excitation from the previous excitatory wave is significant at the beginning of the next excitation. In particular, it is designed for treatment of fast cardiac arrhythmias. Electrical signals are acquired from recording electrodes, and an inverse dipole method is used to identify the site of origin of an arrhythmia. The location of the tip of an ablation catheter is similarly localized from signals acquired from the recording electrodes while electrical pacing energy is delivered to the tip of the catheter close to or in contact with the cardiac tissue. The catheter tip is then guided to the site of origin of the arrhythmia, and ablative radio frequency energy is delivered to its tip to ablate the site.

  17. Real-time ECG monitoring and arrhythmia detection using Android-based mobile devices.

    PubMed

    Gradl, Stefan; Kugler, Patrick; Lohmuller, Clemens; Eskofier, Bjoern

    2012-01-01

    We developed an application for Android™-based mobile devices that allows real-time electrocardiogram (ECG) monitoring and automated arrhythmia detection by analyzing ECG parameters. ECG data provided by pre-recorded files or acquired live by accessing a Shimmer™ sensor node via Bluetooth™ can be processed and evaluated. The application is based on the Pan-Tompkins algorithm for QRS-detection and contains further algorithm blocks to detect abnormal heartbeats. The algorithm was validated using the MIT-BIH Arrhythmia and MIT-BIH Supraventricular Arrhythmia databases. More than 99% of all QRS complexes were detected correctly by the algorithm. Overall sensitivity for abnormal beat detection was 89.5% with a specificity of 80.6%. The application is available for download and may be used for real-time ECG-monitoring on mobile devices.

  18. Patient characteristics associated with false arrhythmia alarms in intensive care

    PubMed Central

    Harris, Patricia R; Zègre-Hemsey, Jessica K; Schindler, Daniel; Bai, Yong; Pelter, Michele M; Hu, Xiao

    2017-01-01

    Introduction A high rate of false arrhythmia alarms in the intensive care unit (ICU) leads to alarm fatigue, the condition of desensitization and potentially inappropriate silencing of alarms due to frequent invalid and nonactionable alarms, often referred to as false alarms. Objective The aim of this study was to identify patient characteristics, such as gender, age, body mass index, and diagnosis associated with frequent false arrhythmia alarms in the ICU. Methods This descriptive, observational study prospectively enrolled patients who were consecutively admitted to one of five adult ICUs (77 beds) at an urban medical center over a period of 31 days in 2013. All monitor alarms and continuous waveforms were stored on a secure server. Nurse scientists with expertise in cardiac monitoring used a standardized protocol to annotate six clinically important types of arrhythmia alarms (asystole, pause, ventricular fibrillation, ventricular tachycardia, accelerated ventricular rhythm, and ventricular bradycardia) as true or false. Total monitoring time for each patient was measured, and the number of false alarms per hour was calculated for these six alarm types. Medical records were examined to acquire data on patient characteristics. Results A total of 461 unique patients (mean age =60±17 years) were enrolled, generating a total of 2,558,760 alarms, including all levels of arrhythmia, parameter, and technical alarms. There were 48,404 hours of patient monitoring time, and an average overall alarm rate of 52 alarms/hour. Investigators annotated 12,671 arrhythmia alarms; 11,345 (89.5%) were determined to be false. Two hundred and fifty patients (54%) generated at least one of the six annotated alarm types. Two patients generated 6,940 arrhythmia alarms (55%). The number of false alarms per monitored hour for patients’ annotated arrhythmia alarms ranged from 0.0 to 7.7, and the duration of these false alarms per hour ranged from 0.0 to 158.8 seconds. Patient characteristics were compared in relation to 1) the number and 2) the duration of false arrhythmia alarms per 24-hour period, using nonparametric statistics to minimize the influence of outliers. Among the significant associations were the following: age ≥60 years (P=0.013; P=0.034), confused mental status (P<0.001 for both comparisons), cardiovascular diagnoses (P<0.001 for both comparisons), electrocardiographic (ECG) features, such as wide ECG waveforms that correspond to ventricular depolarization known as QRS complex due to bundle branch block (BBB) (P=0.003; P=0.004) or ventricular paced rhythm (P=0.002 for both comparisons), respiratory diagnoses (P=0.004 for both comparisons), and support with mechanical ventilation, including those with primary diagnoses other than respiratory ones (P<0.001 for both comparisons). Conclusion Patients likely to trigger a higher number of false arrhythmia alarms may be those with older age, confusion, cardiovascular diagnoses, and ECG features that indicate BBB or ventricular pacing, respiratory diagnoses, and mechanical ventilatory support. Algorithm improvements could focus on better noise reduction (eg, motion artifact with confused state) and distinguishing BBB and paced rhythms from ventricular arrhythmias. Increasing awareness of patient conditions that apparently trigger a higher rate of false arrhythmia alarms may be useful for reducing unnecessary noise and improving alarm management. PMID:28458554

  19. Devices for Arrhythmia

    MedlinePlus

    ... with recurrent arrhythmias, medical devices such as a pacemaker and implantable cardioverter defibrillator (ICD) can help by ... with an ICD Questions to ask your doctor Pacemakers Learn what an artificial pacemaker is, how it ...

  20. The effect of acetyl strophanthidin on the hearts of normal dogs.

    PubMed

    Hayes, A H; McShane, W P; Sidell, F R

    1970-05-01

    1. The ED50 of acetyl strophanthidin for producing ventricular arrhythmias in normal dogs was 54.5 mug/kg intravenously.2. Doses up to and including those which caused ventricular tachycardia did not produce either atrial arrhythmias or significant aberration of A-V conduction.3. Although the classic digitalis-induced rate and e.c.g. waveform changes may appear after administration of acetyl strophanthidin, their presence or absence have no value in predicting the subsequent development of ventricular arrhythmias.

  1. Arrhythmias in Patients with Atrial Defects.

    PubMed

    Contractor, Tahmeed; Mandapati, Ravi

    2017-06-01

    Atrial arrhythmias are common in patients with atrial septal defects. A myriad of factors are responsible for these that include remodeling related to the defect and scar created by the repair or closure. An understanding of potential arrhythmias, along with entrainment and high-density activation mapping can result in accurate diagnosis and successful ablation. Atrial fibrillation is being seen increasingly after patent foramen ovale closure and may be the primary etiology of recurrent stroke in these patients. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Tpeak - Tend and Tpeak - Tend /QT ratio as markers of ventricular arrhythmia risk in cardiac resynchronization therapy patients.

    PubMed

    Barbhaiya, Chirag; Po, Jose Ricardo F; Hanon, Sam; Schweitzer, Paul

    2013-01-01

    Cardiac resynchronization therapy (CRT) increases transmural dispersion of repolarization (TDR) and can be pro-arrhythmic. However, overall arrhythmia risk was not increased in large-scale CRT clinical trials. Increased TDR as measured by T(peak ) -T(end) (TpTe) was associated with arrhythmia risk in CRT in a single-center study. This study investigates whether QT interval, TpTe, and TpTe/QT ratio are associated with ventricular arrhythmias in patients with CRT-defibrillator (CRT-D). Post-CRT-D implant electrocardiograms of 128 patients (age 71.3 years ± 10.3) with at least 2 months of follow-up at our institution's device clinic (mean follow-up of 28.5 months ± 17) were analyzed for QT interval, TpTe, and TpTe/QT ratio. Incidence of ventricular arrhythmias was determined based on routine and directed device interrogations. Appropriate implantable cardioverter-defibrillator therapy for sustained ventricular tachycardia or ventricular fibrillation was delivered in 18 patients (14%), and nonsustained ventricular tachycardia (NSVT) was detected but did not require therapy in 58 patients (45%). Patients who received appropriate defibrillator therapy had increased TpTe/QT ratio (0.24 ± 0.03 ms vs 0.20 ± 0.04, P = 0.0002) and increased TpTe (105.56 ± 20.36 vs 87.82 ± 22.32 ms, P = 0.002), and patients with NSVT had increased TpTe/QT ratio (0.22 ± 0.04 vs 0.20 ± 0.04, P = 0.016). Increased QT interval was not associated with risk of ventricular arrhythmia. The relative risk for appropriate defibrillator therapy of T(p) T(e) /QT ratio ≥ 0.25 was 3.24 (P = 0.016). Increased TpTe and increased TpTe/QT ratio are associated with increased incidence of ventricular arrhythmias in CRT-D. The utility of TpTe interval and TpTe/QT ratio as potentially modifiable risk factors for ventricular arrhythmias in CRT requires further study. ©2012, The Authors. Journal compilation ©2012 Wiley Periodicals, Inc.

  3. Arrhythmogenic KCNE gene variants: current knowledge and future challenges

    PubMed Central

    Crump, Shawn M.; Abbott, Geoffrey W.

    2014-01-01

    There are twenty-five known inherited cardiac arrhythmia susceptibility genes, all of which encode either ion channel pore-forming subunits or proteins that regulate aspects of ion channel biology such as function, trafficking, and localization. The human KCNE gene family comprises five potassium channel regulatory subunits, sequence variants in each of which are associated with cardiac arrhythmias. KCNE gene products exhibit promiscuous partnering and in some cases ubiquitous expression, hampering efforts to unequivocally correlate each gene to specific native potassium currents. Likewise, deducing the molecular etiology of cardiac arrhythmias in individuals harboring rare KCNE gene variants, or more common KCNE polymorphisms, can be challenging. In this review we provide an update on putative arrhythmia-causing KCNE gene variants, and discuss current thinking and future challenges in the study of molecular mechanisms of KCNE-associated cardiac rhythm disturbances. PMID:24478792

  4. Use of sodium bicarbonate to treat tricyclic antidepressant-induced arrhythmias in a patient with alkalosis.

    PubMed Central

    Molloy, D W; Penner, S B; Rabson, J; Hall, K W

    1984-01-01

    Sodium bicarbonate has been recommended for the treatment of arrhythmias induced by tricyclic antidepressants. It is unclear, however, whether this therapy is effective only in the presence of acidosis. A case is presented in which there was an immediate response to sodium bicarbonate in three episodes of ventricular tachycardia despite the presence of alkalosis on two of the three occasions. Given the poor response to conventional therapy of arrhythmias induced by tricyclic antidepressants the use of sodium bicarbonate may be reasonable even in the presence of alkalosis. However, in the presence of pre-existing respiratory or metabolic alkalosis, such therapy is not without risk, and it is suggested that it be reserved for life-threatening situations when the arrhythmia has failed to respond to hyperventilation or antiarrhythmics or both. PMID:6329501

  5. Should an implanted defibrillator be considered in patients with vasospastic angina?

    PubMed

    Eschalier, Romain; Souteyrand, Géraud; Jean, Frédéric; Roux, Antoine; Combaret, Nicolas; Saludas, Yannick; Clerfond, Guillaume; Barber-Chamoux, Nicolas; Citron, Bernard; Lusson, Jean-René; Brugada, Pedro; Motreff, Pascal

    2014-01-01

    Vasospastic angina is a frequent and well-recognized pathology with a high risk of life-threatening ventricular arrhythmias and sudden cardiac death. The diagnosis of vasospastic angina requires the combination of clinical and electrocardiographic variables and the results of provocation tests, such as ergonovine administration. Smoking cessation is the first step in the management of vasospastic angina. Optimal medical treatment using calcium-channel blockers and/or nitrate derivatives can provide protection, but life-threatening ventricular arrhythmias may occur despite optimal medical treatment and several years after the start of treatment. In this review, we evaluate the role of implantable defibrillators as a complement to optimal medical management in patients with life-threatening ventricular arrhythmias due to vasospastic angina; this role is not well characterized in the literature or guidelines. We discuss the role of implantable defibrillators in secondary prevention in light of three recent cases managed in our departments and a review of the literature. An implantable defibrillator was implanted in two of the three cases of vasospastic angina with ventricular arrhythmias that we managed. We considered secondary prevention by implantable defibrillator to be justified even in the absence of any obvious risk factor. Ventricular arrhythmias recurred during implantable defibrillator follow-up in the two patients implanted. In patients with life-threatening ventricular arrhythmias due to vasospastic angina, an implantable defibrillator should be considered because of the risk of recurrence despite optimal medical management. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  6. Metabolic Syndrome Remodels Electrical Activity of the Sinoatrial Node and Produces Arrhythmias in Rats

    PubMed Central

    Albarado-Ibañez, Alondra; Avelino-Cruz, José Everardo; Velasco, Myrian; Torres-Jácome, Julián; Hiriart, Marcia

    2013-01-01

    In the last ten years, the incidences of metabolic syndrome and supraventricular arrhythmias have greatly increased. The metabolic syndrome is a cluster of alterations, which include obesity, hypertension, hypertriglyceridemia, glucose intolerance and insulin resistance, that increase the risk of developing, among others, atrial and nodal arrhythmias. The aim of this study is to demonstrate that metabolic syndrome induces electrical remodeling of the sinus node and produces arrhythmias. We induced metabolic syndrome in 2-month-old male Wistar rats by administering 20% sucrose in the drinking water. Eight weeks later, the rats were anesthetized and the electrocardiogram was recorded, revealing the presence of arrhythmias only in treated rats. Using conventional microelectrode and voltage clamp techniques, we analyzed the electrical activity of the sinoatrial node. We observed that in the sinoatrial node of “metabolic syndrome rats”, compared to controls, the spontaneous firing of all cells decreased, while the slope of the diastolic depolarization increased only in latent pacemaker cells. Accordingly, the pacemaker currents If and Ist increased. Furthermore, histological analysis showed a large amount of fat surrounding nodal cardiomyocytes and a rise in the sympathetic innervation. Finally, Poincaré plot denoted irregularity in the R-R and P-P ECG intervals, in agreement with the variability of nodal firing potential recorded in metabolic syndrome rats. We conclude that metabolic syndrome produces a dysfunction SA node by disrupting normal architecture and the electrical activity, which could explain the onset of arrhythmias in rats. PMID:24250786

  7. Association of Air Pollution with Increased Incidence of Ventricular Tachyarrhythmias Recorded by Implanted Cardioverter Defibrillators

    PubMed Central

    Dockery, Douglas W.; Luttmann-Gibson, Heike; Rich, David Q.; Link, Mark S.; Mittleman, Murray A.; Gold, Diane R.; Koutrakis, Petros; Schwartz, Joel D.; Verrier, Richard L.

    2005-01-01

    Epidemiologic studies have demonstrated a consistent link between sudden cardiac deaths and particulate air pollution. We used implanted cardioverter defibrillator (ICD) records of ventricular tachyarrhythmias to assess the role of air pollution as a trigger of these potentially life-threatening events. The study cohort consisted of 203 cardiac patients with ICD devices in the Boston metropolitan area who were followed for an average of 3.1 years between 1995 and 2002. Fine particle mass and gaseous air pollution plus temperature and relative humidity were measured on almost all days, and black carbon, sulfate, and particle number on a subset of days. Date, time, and intracardiac electrograms of ICD-detected arrhythmias were downloaded at the patients’ regular follow-up visits (about every 3 months). Ventricular tachyarrhythmias were identified by electrophysiologist review. Risk of ventricular arrhythmias associated with air pollution was estimated with logistic regression, adjusting for season, temperature, relative humidity, day of the week, patient, and a recent prior arrhythmia. We found increased risks of ventricular arrhythmias associated with 2-day mean exposure for all air pollutants considered, although these associations were not statistically significant. We found statistically significant associations between air pollution and ventricular arrhythmias for episodes within 3 days of a previous arrhythmia. The associations of ventricular tachyarrhythmias with fine particle mass, carbon monoxide, nitrogen dioxide, and black carbon suggest a link with motor vehicle pollutants. The associations with sulfate suggest a link with stationary fossil fuel combustion sources. PMID:15929887

  8. Capture of activation during ventricular arrhythmia using distributed stimulation.

    PubMed

    Meunier, Jason M; Ramalingam, Sanjiv; Lin, Shien-Fong; Patwardhan, Abhijit R

    2007-04-01

    Results of previous studies suggest that pacing strength stimuli can capture activation during ventricular arrhythmia locally near pacing sites. The existence of spatio-temporal distribution of excitable gap during arrhythmia suggests that multiple and timed stimuli delivered over a region may permit capture over larger areas. Our objective in this study was to evaluate the efficacy of using spatially distributed pacing (DP) to capture activation during ventricular arrhythmia. Data were obtained from rabbit hearts which were placed against a lattice of parallel wires through which biphasic pacing stimuli were delivered. Electrical activity was recorded optically. Pacing stimuli were delivered in sequence through the parallel wires starting with the wire closest to the apex and ending with one closest to the base. Inter-stimulus delay was based on conduction velocity. Time-frequency analysis of optical signals was used to determine variability in activation. A decrease in standard deviation of dominant frequencies of activation from a grid of locations that spanned the captured area and a concurrence with paced frequency were used as an index of capture. Results from five animals showed that the average standard deviation decreased from 0.81 Hz during arrhythmia to 0.66 Hz during DP at pacing cycle length of 125 ms (p = 0.03) reflecting decreased spatio-temporal variability in activation during DP. Results of time-frequency analysis during these pacing trials showed agreement between activation and paced frequencies. These results show that spatially distributed and timed stimulation can be used to modify and capture activation during ventricular arrhythmia.

  9. Metabolic syndrome remodels electrical activity of the sinoatrial node and produces arrhythmias in rats.

    PubMed

    Albarado-Ibañez, Alondra; Avelino-Cruz, José Everardo; Velasco, Myrian; Torres-Jácome, Julián; Hiriart, Marcia

    2013-01-01

    In the last ten years, the incidences of metabolic syndrome and supraventricular arrhythmias have greatly increased. The metabolic syndrome is a cluster of alterations, which include obesity, hypertension, hypertriglyceridemia, glucose intolerance and insulin resistance, that increase the risk of developing, among others, atrial and nodal arrhythmias. The aim of this study is to demonstrate that metabolic syndrome induces electrical remodeling of the sinus node and produces arrhythmias. We induced metabolic syndrome in 2-month-old male Wistar rats by administering 20% sucrose in the drinking water. Eight weeks later, the rats were anesthetized and the electrocardiogram was recorded, revealing the presence of arrhythmias only in treated rats. Using conventional microelectrode and voltage clamp techniques, we analyzed the electrical activity of the sinoatrial node. We observed that in the sinoatrial node of "metabolic syndrome rats", compared to controls, the spontaneous firing of all cells decreased, while the slope of the diastolic depolarization increased only in latent pacemaker cells. Accordingly, the pacemaker currents If and Ist increased. Furthermore, histological analysis showed a large amount of fat surrounding nodal cardiomyocytes and a rise in the sympathetic innervation. Finally, Poincaré plot denoted irregularity in the R-R and P-P ECG intervals, in agreement with the variability of nodal firing potential recorded in metabolic syndrome rats. We conclude that metabolic syndrome produces a dysfunction SA node by disrupting normal architecture and the electrical activity, which could explain the onset of arrhythmias in rats.

  10. In Vitro and In Silico Risk Assessment in Acquired Long QT Syndrome: The Devil Is in the Details.

    PubMed

    Lee, William; Windley, Monique J; Vandenberg, Jamie I; Hill, Adam P

    2017-01-01

    Acquired long QT syndrome, mostly as a result of drug block of the Kv11. 1 potassium channel in the heart, is characterized by delayed cardiac myocyte repolarization, prolongation of the T interval on the ECG, syncope and sudden cardiac death due to the polymorphic ventricular arrhythmia Torsade de Pointes (TdP). In recent years, efforts are underway through the Comprehensive in vitro proarrhythmic assay (CiPA) initiative, to develop better tests for this drug induced arrhythmia based in part on in silico simulations of pharmacological disruption of repolarization. However, drug binding to Kv11.1 is more complex than a simple binary molecular reaction, meaning simple steady state measures of potency are poor surrogates for risk. As a result, there is a plethora of mechanistic detail describing the drug/Kv11.1 interaction-such as drug binding kinetics, state preference, temperature dependence and trapping-that needs to be considered when developing in silico models for risk prediction. In addition to this, other factors, such as multichannel pharmacological profile and the nature of the ventricular cell models used in simulations also need to be considered in the search for the optimum in silico approach. Here we consider how much of mechanistic detail needs to be included for in silico models to accurately predict risk and further, how much of this detail can be retrieved from protocols that are practical to implement in high throughout screens as part of next generation of preclinical in silico drug screening approaches?

  11. Reduction in dynamin-2 is implicated in ischaemic cardiac arrhythmias

    PubMed Central

    Shi, Dan; Xie, Duanyang; Zhang, Hong; Zhao, Hong; Huang, Jian; Li, Changming; Liu, Yi; Lv, Fei; The, Erlinda; Liu, Yuan; Yuan, Tianyou; Wang, Shiyi; Chen, Jinjin; Pan, Lei; Yu, Zuoren; Liang, Dandan; Zhu, Weidong; Zhang, Yuzhen; Li, Li; Peng, Luying; Li, Jun; Chen, Yi-Han

    2014-01-01

    Ischaemic cardiac arrhythmias cause a large proportion of sudden cardiac deaths worldwide. The ischaemic arrhythmogenesis is primarily because of the dysfunction and adverse remodelling of sarcolemma ion channels. However, the potential regulators of sarcolemma ion channel turnover and function in ischaemic cardiac arrhythmias remains unknown. Our previous studies indicate that dynamin-2 (DNM2), a cardiac membrane-remodelling GTPase, modulates ion channels membrane trafficking in the cardiomyocytes. Here, we have found that DNM2 plays an important role in acute ischaemic arrhythmias. In rat ventricular tissues and primary cardiomyocytes subjected to acute ischaemic stress, the DNM2 protein and transcription levels were markedly down-regulated. This DNM2 reduction was coupled with severe ventricular arrhythmias. Moreover, we identified that the down-regulation of DNM2 within cardiomyocytes increases the action potential amplitude and prolongs the re-polarization duration by depressing the retrograde trafficking of Nav1.5 and Kir2.1 channels. These effects are likely to account for the DNM2 defect-induced arrhythmogenic potentials. These results suggest that DNM2, with its multi-ion channel targeting properties, could be a promising target for novel antiarrhythmic therapies. PMID:25092467

  12. Arrhythmia during extracorporeal shock wave lithotripsy.

    PubMed

    Zeng, Z R; Lindstedt, E; Roijer, A; Olsson, S B

    1993-01-01

    A prospective study of arrhythmia during extracorporeal shock wave lithotripsy (ESWL) was performed in 50 patients, using an EDAP LT01 piezoelectric lithotriptor. The 12-lead standard ECG was recorded continuously for 10 min before and during treatment. One or more atrial and/or ventricular ectopic beats occurred during ESWL in 15 cases (30%). The occurrence of arrhythmia was similar during right-sided and left-sided treatment. One patient developed multifocal ventricular premature beats and ventricular bigeminy; another had cardiac arrest for 13.5 s. It was found that various irregularities of the heart rhythm can be caused even by treatment with a lithotriptor using piezoelectric energy to create the shock wave. No evidence was found, however, that the shock wave itself rather than vagal activation and the action of sedo-analgesia was the cause of the arrhythmia. For patients with severe underlying heart disease and a history of complex arrhythmia, we suggest that the ECG be monitored during treatment. In other cases, we have found continuous monitoring of oxygen saturation and pulse rate with a pulse oximeter to be perfectly reliable for raising the alarm when depression of respiration and vaso-vagal reactions occur.

  13. Correlation-based pattern recognition for implantable defibrillators.

    PubMed Central

    Wilkins, J.

    1996-01-01

    An estimated 300,000 Americans die each year from cardiac arrhythmias. Historically, drug therapy or surgery were the only treatment options available for patients suffering from arrhythmias. Recently, implantable arrhythmia management devices have been developed. These devices allow abnormal cardiac rhythms to be sensed and corrected in vivo. Proper arrhythmia classification is critical to selecting the appropriate therapeutic intervention. The classification problem is made more challenging by the power/computation constraints imposed by the short battery life of implantable devices. Current devices utilize heart rate-based classification algorithms. Although easy to implement, rate-based approaches have unacceptably high error rates in distinguishing supraventricular tachycardia (SVT) from ventricular tachycardia (VT). Conventional morphology assessment techniques used in ECG analysis often require too much computation to be practical for implantable devices. In this paper, a computationally-efficient, arrhythmia classification architecture using correlation-based morphology assessment is presented. The architecture classifies individuals heart beats by assessing similarity between an incoming cardiac signal vector and a series of prestored class templates. A series of these beat classifications are used to make an overall rhythm assessment. The system makes use of several new results in the field of pattern recognition. The resulting system achieved excellent accuracy in discriminating SVT and VT. PMID:8947674

  14. Autonomic reactivity during viewing of an unpleasant film.

    PubMed

    Baldaro, B; Mazzetti, M; Codispoti, M; Tuozzi, G; Bolzani, R; Trombini, G

    2001-12-01

    The effect of an aversive, high-arousing film on heart rate, respiratory sinus arrhythmia, and electrogastrographic activity (EGG) was investigated. Previous studies have indicated a larger heart-rate deceleration for visual stimuli depicting surgery or blood compared to neutral content, and this phenomenon is similar to the bradycardia observed in animals in response to fear. The heart-rate deceleration is clearly parasympathetically driven, and it is considered a general index of attention. An accurate index of cardiac vagal tone can be obtained by means of quantification of the amplitude of respiratory sinus arrhythmia. The relationship between cardiac vagal tone and EGG is complex, but animal research has shown that suppressing vagal activity dampens gastric motility. We have investigated whether a movie depicting surgery is associated with greater heart-rate deceleration, larger increase in respiratory sinus arrhythmia, and greater increase in EGG activity compared to a neutral movie. In addition, if both respiratory sinus arrhythmia and EGG are indices of vagal tone, a positive correlation between these physiological responses was expected. Analysis indicated an effect of the surgery movie on heart rate and respiratory sinus arrhythmia, but not on EGG activity. Moreover, the expected correlation was not found. Implications for future studies are discussed.

  15. Multiclass Classification of Cardiac Arrhythmia Using Improved Feature Selection and SVM Invariants.

    PubMed

    Mustaqeem, Anam; Anwar, Syed Muhammad; Majid, Muahammad

    2018-01-01

    Arrhythmia is considered a life-threatening disease causing serious health issues in patients, when left untreated. An early diagnosis of arrhythmias would be helpful in saving lives. This study is conducted to classify patients into one of the sixteen subclasses, among which one class represents absence of disease and the other fifteen classes represent electrocardiogram records of various subtypes of arrhythmias. The research is carried out on the dataset taken from the University of California at Irvine Machine Learning Data Repository. The dataset contains a large volume of feature dimensions which are reduced using wrapper based feature selection technique. For multiclass classification, support vector machine (SVM) based approaches including one-against-one (OAO), one-against-all (OAA), and error-correction code (ECC) are employed to detect the presence and absence of arrhythmias. The SVM method results are compared with other standard machine learning classifiers using varying parameters and the performance of the classifiers is evaluated using accuracy, kappa statistics, and root mean square error. The results show that OAO method of SVM outperforms all other classifiers by achieving an accuracy rate of 81.11% when used with 80/20 data split and 92.07% using 90/10 data split option.

  16. Evaluation of heart rhythm variability and arrhythmia in children with systemic and localized scleroderma.

    PubMed

    Wozniak, Jacek; Dabrowski, Rafal; Luczak, Dariusz; Kwiatkowska, Malgorzata; Musiej-Nowakowska, Elzbieta; Kowalik, Ilona; Szwed, Hanna

    2009-01-01

    To evaluate possible disturbances in autonomic regulation and cardiac arrhythmias in children with localized and systemic scleroderma. There were 40 children included in the study: 20 with systemic and 20 with localized scleroderma. The control group comprised 20 healthy children. In 24-hour Holter recording, the average rate of sinus rhythm was significantly higher in the groups with systemic and localized scleroderma than in the control group, but there was no significant difference between them. The variability of heart rhythm in both groups was significantly decreased. In the group with systemic scleroderma, single supraventricular ectopic beats were observed in 20% and runs were seen in 40% of patients. In the group with localized scleroderma, supraventricular single ectopic beats occurred in 35% of patients and runs in 45% of those studied. Ventricular arrhythmia occurred in 2 children with systemic scleroderma, but in 1 child, it was complex. The most frequent cardiac arrhythmias in both types of scleroderma in children were of supraventricular origin, whereas ventricular arrhythmias did not occur very often. There were no significant differences in autonomic disturbances manifesting as a higher heart rate and decreased heart rate variability between localized and systemic scleroderma.

  17. Ventricular arrhythmias and changes in heart rate preceding ventricular tachycardia in patients with an implantable cardioverter defibrillator.

    PubMed

    Lerma, Claudia; Wessel, Niels; Schirdewan, Alexander; Kurths, Jürgen; Glass, Leon

    2008-07-01

    The objective was to determine the characteristics of heart rate variability and ventricular arrhythmias prior to the onset of ventricular tachycardia (VT) in patients with an implantable cardioverter defibrillator (ICD). Sixty-eight beat-to-beat time series from 13 patients with an ICD were analyzed to quantify heart rate variability and ventricular arrhythmias. The episodes of VT were classified in one of two groups depending on whether the sinus rate in the 1 min preceding the VT was greater or less than 90 beats per minute. In a subset of patients, increased heart rate and reduced heart rate variability was often observed up to 20 min prior to the VT. There was a non-significant trend to higher incidence of premature ventricular complexes (PVCs) before VT compared to control recordings. The patterns of the ventricular arrhythmias were highly heterogeneous among different patients and even within the same patient. Analysis of the changes of heart rate and heart rate variability may have predictive value about the onset of VT in selected patients. The patterns of ventricular arrhythmia could not be used to predict onset of VT in this group of patients.

  18. Students' Perception of Peer and Faculty Debriefing Facilitators Following Simulation- Based Education.

    PubMed

    Doherty-Restrepo, Jennifer; Odai, Michelle; Harris, Meisha; Yam, Tiffany; Potteiger, Kelly; Montalvo, Alicia

    2018-01-01

    Debriefing (discussion led by a facilitator) in simulation-based education enhances dual learning for facilitators and students. Debriefing guides students to critically reflect on their performance in a simulation setting, thus allowing improvement in cognitive and clinical skills. Research has examined the effectiveness of simulation-based education on knowledge, skills, and confidence; however, less research has examined students' perception of debriefing. To compare peer- and faculty-facilitated debriefing on students' confidence and perceptions of simulation effectiveness. Pretest-posttest design, evaluating 23 first-year athletic training students in a CAATE-accredited professional master's program. Participants responded to a series of questions at pre- and posttest using the Debriefing Assessment for Simulation in Healthcare (DASH) to evaluate participant self-confidence of select clinical skills and perceived effectiveness of debriefing. Participants reported a significant increase from pretest to posttest in their confidence in making a differential diagnosis (F=4.26, p=0.03) and ability to share thoughts and emotions without fear of being shamed or humiliated (F=2.08, p=0.05). Students perceived peer- and faculty-facilitated debriefing as equally effective. Peers may assume a facilitator role and provide an effective debriefing session following simulation.

  19. Pacemakers and Implantable Defibrillators: MedlinePlus Health Topic

    MedlinePlus

    ... pattern. Most arrhythmias result from problems in the electrical system of the heart. If your arrhythmia is ... pacemaker helps control abnormal heart rhythms. It uses electrical pulses to prompt the heart to beat at ...

  20. 21 CFR 870.1025 - Arrhythmia detector and alarm (including ST-segment measurement and alarm).

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... a visible or audible signal or alarm when atrial or ventricular arrhythmia, such as premature contraction or ventricular fibrillation, occurs. (b) Classification. Class II (special controls). The guidance...

  1. 21 CFR 870.1025 - Arrhythmia detector and alarm (including ST-segment measurement and alarm).

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... a visible or audible signal or alarm when atrial or ventricular arrhythmia, such as premature contraction or ventricular fibrillation, occurs. (b) Classification. Class II (special controls). The guidance...

  2. Types of Arrhythmia in Children

    MedlinePlus

    ... even though they may need to keep taking medicine. Your child will probably need periodic check-ups but will ... minute. Understand and manage medications Parents of a child taking medicine for an arrhythmia should give the medicine at ...

  3. Doxorubicin-induced second degree and complete atrioventricular block.

    PubMed

    Kilickap, Saadettin; Akgul, Ebru; Aksoy, Sercan; Aytemir, Kudret; Barista, Ibrahim

    2005-05-01

    Doxorubicin is one of the most effective chemotherapeutic agents used in the treatment of malignancies. Cardiotoxicity is the most important dose-limiting toxicity of doxorubicin. Although cardiomyopathy is the most well known side effect of doxorubicin, it usually occurs many years after the treatment and relates to cumulative doxorubicin dosage. Another form of doxorubicin cardiotoxicity is arrhythmia which may occur at any time and after any dosage. However, doxorubicin-induced arrhythmia is rarely a life-threatening side effect. In this report, we present a case in which there were doxorubicin-induced life-threatening arrhythmias.

  4. Disproportionality analysis of buprenorphine transdermal system and cardiac arrhythmia using FDA and WHO postmarketing reporting system data.

    PubMed

    Sessler, Nelson E; Walker, Ekaterina; Chickballapur, Harsha; Kacholakalayil, James; Coplan, Paul M

    2017-01-01

    Positive-controlled clinical studies have shown a dose dependent effect of buprenorphine transdermal system on QTc interval prolongation. This study provides assessment of the buprenorphine transdermal system and cardiac arrhythmia using US FDA and WHO postmarketing reporting databases. Disproportionality analysis of spontaneously reported adverse events to assess whether the reporting rate of cardiac arrhythmia events was disproportionately elevated relative to expected rates of reporting in both FDA and WHO databases. Cardiac arrhythmia events were identified using the standardized Medical Dictionary for Regulatory Activities query for torsade de pointes and/or QT prolongation (TdP/QTP). The threshold for a signal of disproportionate adverse event reporting was defined as the lower 90% confidence limit ≥ 2 of the Empiric Bayes geometric mean in FDA database and as the lower 95% confidence limit of the Informational Component >0 in WHO database. There were 124 (<1%) and 77 (2%) cardiac arrhythmia event cases associated with buprenorphine transdermal as compared to 3206 (12%) and 2913 (14%) involving methadone in the FDA and WHO databases, respectively. In the FDA database methadone was associated with a signal of disproportionate reporting for TdP/QTP (EB05 3.26); however, buprenorphine transdermal was not (EB05 0.33). In the WHO database methadone was associated with a signal of disproportionate reporting for TdP/QTP (IC025 2.66); however, buprenorphine transdermal was not (IC025 -0.88). Similar trends were observed in sensitivity analyses by age, gender, and specific terms related to ventricular arrhythmia. The signal identified in the transdermal buprenorphine thorough QTc study, which led to a dose limitation in its US label, does not translate into a signal of increased risk for cardiac arrhythmia in real world use, as assessed by this method of analyzing post-market surveillance data.

  5. Computers and clinical arrhythmias.

    PubMed

    Knoebel, S B; Lovelace, D E

    1983-02-01

    Cardiac arrhythmias are ubiquitous in normal and abnormal hearts. These disorders may be life-threatening or benign, symptomatic or unrecognized. Arrhythmias may be the precursor of sudden death, a cause or effect of cardiac failure, a clinical reflection of acute or chronic disorders, or a manifestation of extracardiac conditions. Progress is being made toward unraveling the diagnostic and therapeutic problems involved in arrhythmogenesis. Many of the advances would not be possible, however, without the availability of computer technology. To preserve the proper balance and purposeful progression of computer usage, engineers and physicians have been exhorted not to work independently in this field. Both should learn some of the other's trade. The two disciplines need to come together to solve important problems with computers in cardiology. The intent of this article was to acquaint the practicing cardiologist with some of the extant and envisioned computer applications and some of the problems with both. We conclude that computer-based database management systems are necessary for sorting out the clinical factors of relevance for arrhythmogenesis, but computer database management systems are beset with problems that will require sophisticated solutions. The technology for detecting arrhythmias on routine electrocardiograms is quite good but human over-reading is still required, and the rationale for computer application in this setting is questionable. Systems for qualitative, continuous monitoring and review of extended time ECG recordings are adequate with proper noise rejection algorithms and editing capabilities. The systems are limited presently for clinical application to the recognition of ectopic rhythms and significant pauses. Attention should now be turned to the clinical goals for detection and quantification of arrhythmias. We should be asking the following questions: How quantitative do systems need to be? Are computers required for the detection of all arrhythmias? In all settings? Should we be focusing alternatively on those arrhythmias that are frequent and with clinical significance? The ultimate test of any technology is, after all, its use in advancing knowledge and patient care.

  6. Periodic Limb Movements during Sleep and Cardiac Arrhythmia in Older Men (MrOS Sleep)

    PubMed Central

    Koo, Brian B.; Mehra, Reena; Blackwell, Terri; Ancoli-Israel, Sonia; Stone, Katie L.; Redline, Susan

    2014-01-01

    Study Objectives: To determine if periodic limb movements during sleep (PLMS) are associated with nocturnal cardiac arrhythmia. Methods: 2,793 community-dwelling older men underwent polysomnography with measurement of limb movements and EKG. Logistic regression assessed association of periodic limb movement index and periodic limb movement arousal index with arrhythmia including atrial fibrillation and non-sustained ventricular tachycardia detected by polysomnography. Models were adjusted for age, race, cardiovascular risk factors, and clinic site. Secondary analyses were subset to men without calcium channel/β-adrenergic medication usage, and stratified by congestive heart failure or myocardial infarction history. Results: In the overall cohort, periodic limb movement index, and periodic limb movement arousal index were not associated with ventricular or atrial arrhythmia after considering potential confounders. In men not taking calcium channel/β-blocking medication, increased adjusted odds of non-sustained ventricular tachycardia were observed for periodic limb movement index (OR = 1.30 per SD increase; 95% CI 1.00, 1.68) and periodic limb movement arousal index (OR = 1.29 per SD increase; 95% CI 1.03, 1.62). In men with CHF or MI, there was a suggested association of atrial fibrillation with periodic limb movement index (OR = 1.29, 95% CI 0.96, 1.73 per SD increase; p = 0.09) or periodic limb movement arousal index (OR = 1.21, 95% CI 0.94, 1.57 per SD increase; p = 0.14), although results were not statistically significant. Conclusions: There is not an association between PLMS and cardiac arrhythmia in all older men but in subsets of men, particularly those with structural heart disease and not on calcium channel or β-adrenergic medication, cardiac arrhythmia does associate with PLMS. Citation: Koo BB; Mehra R; Blackwell T; Ancoli-Israel S; Stone KL; Redline S; for the Osteoporotic Fractures in Men (MrOS) Study Group. Periodic limb movements during sleep and cardiac arrhythmia in older men (MrOS sleep). J Clin Sleep Med 2014;10(1):7-11. PMID:24426814

  7. Arrhythmia Associated with Buprenorphine and Methadone Reported to the Food and Drug Administration

    PubMed Central

    Kao, David P; Haigney, Mark CP; Mehler, Philip S; Krantz, Mori J

    2015-01-01

    Aim To assess the relative frequency of reporting of adverse events involving ventricular arrhythmia, cardiac arrest, QTc prolongation, or torsade de pointes to the US Food and Drug Administration (FDA) between buprenorphine and methadone. Design Retrospective pharmacoepidemiologic study Setting Adverse drug events spontaneously reported to the FDA between 1969-June 2011 originating in 196 countries (71% events from the US). Cases Adverse event cases mentioning methadone (n=14,915) or buprenorphine (n=7,283) were evaluated against all other adverse event cases (n= 4,796,141). Measurements The primary outcome was the composite of ventricular arrhythmia or cardiac arrest. The secondary outcome was the composite of QTc prolongation or torsade de pointes. The proportional reporting ratio (PRR) was used to identify disproportionate reporting defined as a PRR>2, χ2 error>4, with ≥3 cases. Findings There were 132 (1.8%) ventricular arrhythmia/cardiac arrest and 19 (0.3%) QTc prolongation/torsade de pointes cases associated with buprenorphine compared with 1729 (11.6%) ventricular arrhythmia/cardiac arrest and 390 (2.6%) QTc prolongation/torsade de pointes cases involving methadone. PRRs associated with buprenorphine were not significant for ventricular arrhythmia/cardiac arrest (1.1 95% confidence interval (CI) 0.9–1.3, χ2=1.2) or QTc prolongation/torsade de pointes (1.0 95% CI 0.7–1.9, χ2=0.0006), but were for methadone (7.2 95% CI 6.9–7.5, χ2=9160; 10.6 95% CI 9.7–11.8, χ2=3305, respectively). Conclusion In spontaneously reported adverse events, methadone is associated with disproportionate reporting of cardiac arrhythmias, whereas buprenorphine is not. Although these findings probably reflect clinically relevant differences, a causal connection cannot be presumed and disproportionality analysis cannot quantify absolute risk per treatment episode. Population-based studies to definitively quantify differential incidence rates are warranted. PMID:26075588

  8. Testing the burden of rare variation in arrhythmia-susceptibility genes provides new insights into molecular diagnosis for Brugada syndrome.

    PubMed

    Le Scouarnec, Solena; Karakachoff, Matilde; Gourraud, Jean-Baptiste; Lindenbaum, Pierre; Bonnaud, Stéphanie; Portero, Vincent; Duboscq-Bidot, Laëtitia; Daumy, Xavier; Simonet, Floriane; Teusan, Raluca; Baron, Estelle; Violleau, Jade; Persyn, Elodie; Bellanger, Lise; Barc, Julien; Chatel, Stéphanie; Martins, Raphaël; Mabo, Philippe; Sacher, Frédéric; Haïssaguerre, Michel; Kyndt, Florence; Schmitt, Sébastien; Bézieau, Stéphane; Le Marec, Hervé; Dina, Christian; Schott, Jean-Jacques; Probst, Vincent; Redon, Richard

    2015-05-15

    The Brugada syndrome (BrS) is a rare heritable cardiac arrhythmia disorder associated with ventricular fibrillation and sudden cardiac death. Mutations in the SCN5A gene have been causally related to BrS in 20-30% of cases. Twenty other genes have been described as involved in BrS, but their overall contribution to disease prevalence is still unclear. This study aims to estimate the burden of rare coding variation in arrhythmia-susceptibility genes among a large group of patients with BrS. We have developed a custom kit to capture and sequence the coding regions of 45 previously reported arrhythmia-susceptibility genes and applied this kit to 167 index cases presenting with a Brugada pattern on the electrocardiogram as well as 167 individuals aged over 65-year old and showing no history of cardiac arrhythmia. By applying burden tests, a significant enrichment in rare coding variation (with a minor allele frequency below 0.1%) was observed only for SCN5A, with rare coding variants carried by 20.4% of cases with BrS versus 2.4% of control individuals (P = 1.4 × 10(-7)). No significant enrichment was observed for any other arrhythmia-susceptibility gene, including SCN10A and CACNA1C. These results indicate that, except for SCN5A, rare coding variation in previously reported arrhythmia-susceptibility genes do not contribute significantly to the occurrence of BrS in a population with European ancestry. Extreme caution should thus be taken when interpreting genetic variation in molecular diagnostic setting, since rare coding variants were observed in a similar extent among cases versus controls, for most previously reported BrS-susceptibility genes. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  9. Atrial SERCA2a Overexpression Has No Affect on Cardiac Alternans but Promotes Arrhythmogenic SR Ca2+ Triggers

    PubMed Central

    Nassal, Michelle M. J.; Wan, Xiaoping; Laurita, Kenneth R.; Cutler, Michael J.

    2015-01-01

    Background Atrial fibrillation (AF) is the most common arrhythmia in humans, yet; treatment has remained sub-optimal due to poor understanding of the underlying mechanisms. Cardiac alternans precede AF episodes, suggesting an important arrhythmia substrate. Recently, we demonstrated ventricular SERCA2a overexpression suppresses cardiac alternans and arrhythmias. Therefore, we hypothesized that atrial SERCA2a overexpression will decrease cardiac alternans and arrhythmias. Methods Adult rat isolated atrial myocytes where divided into three treatment groups 1) Control, 2) SERCA2a overexpression (Ad.SERCA2a) and 3) SERCA2a inhibition (Thapsigargin, 1μm). Intracellular Ca2+ was measured using Indo-1AM and Ca2+ alternans (Ca-ALT) was induced with a standard ramp pacing protocol. Results As predicted, SR Ca2+ reuptake was enhanced with SERCA2a overexpression (p< 0.05) and reduced with SERCA2a inhibition (p<0.05). Surprisingly, there was no difference in susceptibility to Ca-ALT with either SERCA2a overexpression or inhibition when compared to controls (p = 0.73). In contrast, SERCA2a overexpression resulted in increased premature SR Ca2+ (SCR) release compared to control myocytes (28% and 0%, p < 0.05) and concomitant increase in SR Ca2+ load (p<0.05). Based on these observations we tested in-vivo atrial arrhythmia inducibility in control and Ad.SERCA2a animals using an esophageal atrial burst pacing protocol. There were no inducible atrial arrhythmias in Ad.GFP (n = 4) animals though 20% of Ad.SERCA2a (n = 5) animals had inducible atrial arrhythmias (p = 0.20). Conclusions Our findings suggest that unlike the ventricle, SERCA2a is not a key regulator of cardiac alternans in the atrium. Importantly, SERCA2a overexpression in atrial myocytes can increase SCR, which may be arrhythmogenic. PMID:26352986

  10. Prognostic significance of electrical alternans versus signal averaged electrocardiography in predicting the outcome of electrophysiological testing and arrhythmia-free survival

    NASA Technical Reports Server (NTRS)

    Armoundas, A. A.; Rosenbaum, D. S.; Ruskin, J. N.; Garan, H.; Cohen, R. J.

    1998-01-01

    OBJECTIVE: To investigate the accuracy of signal averaged electrocardiography (SAECG) and measurement of microvolt level T wave alternans as predictors of susceptibility to ventricular arrhythmias. DESIGN: Analysis of new data from a previously published prospective investigation. SETTING: Electrophysiology laboratory of a major referral hospital. PATIENTS AND INTERVENTIONS: 43 patients, not on class I or class III antiarrhythmic drug treatment, undergoing invasive electrophysiological testing had SAECG and T wave alternans measurements. The SAECG was considered positive in the presence of one (SAECG-I) or two (SAECG-II) of three standard criteria. T wave alternans was considered positive if the alternans ratio exceeded 3.0. MAIN OUTCOME MEASURES: Inducibility of sustained ventricular tachycardia or fibrillation during electrophysiological testing, and 20 month arrhythmia-free survival. RESULTS: The accuracy of T wave alternans in predicting the outcome of electrophysiological testing was 84% (p < 0.0001). Neither SAECG-I (accuracy 60%; p < 0.29) nor SAECG-II (accuracy 71%; p < 0.10) was a statistically significant predictor of electrophysiological testing. SAECG, T wave alternans, electrophysiological testing, and follow up data were available in 36 patients while not on class I or III antiarrhythmic agents. The accuracy of T wave alternans in predicting the outcome of arrhythmia-free survival was 86% (p < 0.030). Neither SAECG-I (accuracy 65%; p < 0.21) nor SAECG-II (accuracy 71%; p < 0.48) was a statistically significant predictor of arrhythmia-free survival. CONCLUSIONS: T wave alternans was a highly significant predictor of the outcome of electrophysiological testing and arrhythmia-free survival, while SAECG was not a statistically significant predictor. Although these results need to be confirmed in prospective clinical studies, they suggest that T wave alternans may serve as a non-invasive probe for screening high risk populations for malignant ventricular arrhythmias.

  11. Reasons for failed ablation for idiopathic right ventricular outflow tract-like ventricular arrhythmias.

    PubMed

    Yokokawa, Miki; Good, Eric; Crawford, Thomas; Chugh, Aman; Pelosi, Frank; Latchamsetty, Rakesh; Jongnarangsin, Krit; Ghanbari, Hamid; Oral, Hakan; Morady, Fred; Bogun, Frank

    2013-08-01

    The right ventricular outflow tract (RVOT) is the most common site of origin of ventricular arrhythmias (VAs) in patients with idiopathic VAs. A left bundle branch block, inferior axis morphology arrhythmia is the hallmark of RVOT arrhythmias. VAs from other sites of origin can mimic RVOT VAs, and ablation in the RVOT typically fails for these VAs. To analyze reasons for failed ablations of RVOT-like VAs. Among a consecutive series of 197 patients with an RVOT-like electrocardiographic (ECG) morphology who were referred for ablation, 38 patients (13 men; age 46 ± 14 years; left ventricular ejection fraction 47% ± 14%) in whom a prior procedure failed within the RVOT underwent a second ablation procedure. ECG characteristics of the VA were compared to a consecutive series of 50 patients with RVOT VAs. The origin of the VA was identified in 95% of the patients. In 28 of 38 (74%) patients, the arrhythmia origin was not in the RVOT. The VA originated from intramural sites (n = 8, 21%), the pulmonary arteries (n = 7, 18%), the aortic cusps (n = 6, 16%), and the epicardium (n = 5, 13%). The origin was within the RVOT in 10 (26%) patients. In 2 (5%) patients, the origin could not be identified despite biventricular, aortic, and epicardial mapping. The VA was eliminated in 34 of 38 (89%) patients with repeat procedures. The ECG features of patients with failed RVOT-like arrhythmias were different from the characteristics of RVOT arrhythmias. In patients in whom ablation of a VA with an RVOT-like appearance fails, mapping of the pulmonary artery, the aortic cusps, the epicardium, the left ventricular outflow tract, and the aortic cusps will help identify the correct site of origin. The 12-lead ECG is helpful in differentiating these VAs from RVOT VAs. Copyright © 2013 Heart Rhythm Society. All rights reserved.

  12. Arrhythmia recognition and classification using combined linear and nonlinear features of ECG signals.

    PubMed

    Elhaj, Fatin A; Salim, Naomie; Harris, Arief R; Swee, Tan Tian; Ahmed, Taqwa

    2016-04-01

    Arrhythmia is a cardiac condition caused by abnormal electrical activity of the heart, and an electrocardiogram (ECG) is the non-invasive method used to detect arrhythmias or heart abnormalities. Due to the presence of noise, the non-stationary nature of the ECG signal (i.e. the changing morphology of the ECG signal with respect to time) and the irregularity of the heartbeat, physicians face difficulties in the diagnosis of arrhythmias. The computer-aided analysis of ECG results assists physicians to detect cardiovascular diseases. The development of many existing arrhythmia systems has depended on the findings from linear experiments on ECG data which achieve high performance on noise-free data. However, nonlinear experiments characterize the ECG signal more effectively sense, extract hidden information in the ECG signal, and achieve good performance under noisy conditions. This paper investigates the representation ability of linear and nonlinear features and proposes a combination of such features in order to improve the classification of ECG data. In this study, five types of beat classes of arrhythmia as recommended by the Association for Advancement of Medical Instrumentation are analyzed: non-ectopic beats (N), supra-ventricular ectopic beats (S), ventricular ectopic beats (V), fusion beats (F) and unclassifiable and paced beats (U). The characterization ability of nonlinear features such as high order statistics and cumulants and nonlinear feature reduction methods such as independent component analysis are combined with linear features, namely, the principal component analysis of discrete wavelet transform coefficients. The features are tested for their ability to differentiate different classes of data using different classifiers, namely, the support vector machine and neural network methods with tenfold cross-validation. Our proposed method is able to classify the N, S, V, F and U arrhythmia classes with high accuracy (98.91%) using a combined support vector machine and radial basis function method. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  13. Arrhythmogenic Right Ventricular Dysplasia

    MedlinePlus

    ... The heart has 4 sections called chambers. The right ventricle is one of the lower chambers. If you have ARVC, ... Kids and Teens, Men, WomenTags: arrhythmia, Arrhythmias, Arrhythmogenic Right ... April 1, 2006 Copyright © American Academy of Family Physicians This ...

  14. Ubiquitous health monitoring and real-time cardiac arrhythmias detection: a case study.

    PubMed

    Li, Jian; Zhou, Haiying; Zuo, Decheng; Hou, Kun-Mean; De Vaulx, Christophe

    2014-01-01

    As the symptoms and signs of heart diseases that cause sudden cardiac death, cardiac arrhythmia has attracted great attention. Due to limitations in time and space, traditional approaches to cardiac arrhythmias detection fail to provide a real-time continuous monitoring and testing service applicable in different environmental conditions. Integrated with the latest technologies in ECG (electrocardiograph) analysis and medical care, the pervasive computing technology makes possible the ubiquitous cardiac care services, and thus brings about new technical challenges, especially in the formation of cardiac care architecture and realization of the real-time automatic ECG detection algorithm dedicated to care devices. In this paper, a ubiquitous cardiac care prototype system is presented with its architecture framework well elaborated. This prototype system has been tested and evaluated in all the clinical-/home-/outdoor-care modes with a satisfactory performance in providing real-time continuous cardiac arrhythmias monitoring service unlimitedly adaptable in time and space.

  15. Atrial Arrhythmias in Astronauts - Summary of a NASA Summit

    NASA Technical Reports Server (NTRS)

    Barr, Yael R.; Watkins, Sharmila D.; Polk, J. D.

    2010-01-01

    Background and Problem Definition: To evaluate NASA s current standards and practices related to atrial arrhythmias in astronauts, Space Medicine s Advanced Projects Section at the Johnson Space Center was tasked with organizing a summit to discuss the approach to atrial arrhythmias in the astronaut cohort. Since 1959, 11 cases of atrial fibrillation, atrial flutter, or supraventricular tachycardia have been recorded among active corps crewmembers. Most of the cases were paroxysmal, although a few were sustained. While most of the affected crewmembers were asymptomatic, those slated for long-duration space flight underwent radiofrequency ablation treatment to prevent further episodes of the arrhythmia. The summit was convened to solicit expert opinion on screening, diagnosis, and treatment options, to identify gaps in knowledge, and to propose relevant research initiatives. Summit Meeting Objectives: The Atrial Arrhythmia Summit brought together a panel of six cardiologists, including nationally and internationally renowned leaders in cardiac electrophysiology, exercise physiology, and space flight cardiovascular physiology. The primary objectives of the summit discussions were to evaluate cases of atrial arrhythmia in the astronaut population, to understand the factors that may predispose an individual to this condition, to understand NASA s current capabilities for screening, diagnosis, and treatment, to discuss the risks associated with treatment of crewmembers assigned to long-duration missions or extravehicular activities, and to discuss recommendations for prevention or management of future cases. Summary of Recommendations: The summit panel s recommendations were grouped into seven categories: Epidemiology, Screening, Standards and Selection, Treatment of Atrial Fibrillation Manifesting Preflight, Atrial Fibrillation during Flight, Prevention of Atrial Fibrillation, and Future Research

  16. AV-block and conduction slowing prevail over TdP arrhythmias in the methoxamine-sensitized pro-arrhythmic rabbit model.

    PubMed

    Varkevisser, Rosanne; Vos, Marc A; Beekman, Jet D; Tieland, Ralph G; Van Der Heyden, Marcel A

    2015-01-01

    The methoxamine-sensitized rabbit model is widely used to screen drugs for proarrhythmic properties, especially repolarization-dependent TdP arrhythmias. With the change of anesthesia and/or sensitizing agent, conduction disturbances have been reported as well. Therefore, we compared currently available in-house anesthetics in order to preserve arrhythmia sensitivity and preclude conduction disturbances. Rabbits were randomly assigned to 3 groups: (1) 35 mg/kg ketamine + 5 mg/kg xylazine; (2) 0.5 mL/kg hypnorm + 3 mg/kg midazolam; (3) 35 mg/kg ketamine + 20 mg/kg propofol. Anesthesia was maintained by 1.5% isoflurane. Concomitant infusion of methoxamine (17 μg/kg/min for 40 minutes) and dofetilide (10 μg/kg/min for 30 minutes) was used to induce arrhythmias. Sole methoxamine infusion exclusively decreased HR in groups 1 and 3. Dofetilide lengthened repolarization, followed in time by PQ/QRS prolongation, second-degree AV block, and subsequently TdP arrhythmias. TdP was seen in 80%, 0%, and 33% of the rabbits in groups 1, 2, and 3, respectively. Decreasing the dose of dofetilide to 5 μg/kg/min in ketamine/xylazine anesthetized rabbits resulted in a drop in TdP incidence (25%) while conduction disturbances persisted. Flunarizine (n = 6) suppressed all TdP arrhythmias while conduction disturbances remained present. TdP incidence in the methoxamine-sensitized rabbit could be dramatically influenced by anesthesia, drug dose, and flunarizine, while conduction slowing remained present. Thus, conduction slowing seems to be the integral outcome in this model. © 2014 Wiley Periodicals, Inc.

  17. Pharmacy Students’ Performance and Perceptions in a Flipped Teaching Pilot on Cardiac Arrhythmias

    PubMed Central

    Ip, Eric J.; Lopes, Ingrid; Rajagopalan, Vanishree

    2014-01-01

    Objective. To implement the flipped teaching method in a 3-class pilot on cardiac arrhythmias and to assess the impact of the intervention on academic performance and student perceptions. Design. An intervention group of 101 first-year pharmacy students, who took the class with the flipped teaching method, were supplied with prerecorded lectures prior to their 3 classes (1 class in each of the following subjects: basic sciences, pharmacology, and therapeutics) on cardiac arrhythmias. Class time was focused on active-learning and case-based exercises. Students then took a final examination that included questions on cardiac arrhythmias. The examination scores of the intervention group were compared to scores of the Spring 2011 control group of 105 first-year students who took the class with traditional teaching methods. An online survey was conducted to assess student feedback from the intervention group. Assessment. The mean examination scores of the intervention group were significantly higher than the mean examination scores of the control group for the cardiac arrhythmia classes in pharmacology (with 89.6 ± 2.0% vs 56.8 ± 2.2%, respectively) and therapeutics (89.2 ± 1.4% vs 73.7 ± 2.1%, respectively). The survey indicated higher student satisfaction for flipped classes with highly rated learning objectives, recordings, and in-class activities. Conclusion. Use of the flipped teaching method in a 3-class pilot on cardiac arrhythmias improved examination scores for 2 of the 3 classes (pharmacology and therapeutics). Student satisfaction was influenced by the quality of the learning objectives, prerecorded lectures, and inclass active-learning activities. PMID:25657372

  18. Effect of long-term application of Crataegus oxyacantha on ischemia and reperfusion induced arrhythmias in rats.

    PubMed

    Rothfuss, M A; Pascht, U; Kissling, G

    2001-01-01

    The effect of long-term application of Crataegus oxyacantha on ischemia and reperfusion induced arrhythmias was investigated in Wistar rats on the heart in situ and on Langendorff preparations. Seventeen rats were fed for 8 weeks with 0.5 g/kg b.w. Crataegus extract per day, standardised to 2.2% flavonoids. Twenty age-matched untreated rats served as controls. In the hearts in situ as well as in the Langendorff preparations the left anterior descending coronary artery (LAD) was ligated for 20 min and subsequently reperfused for 30 min. ECG was continuously recorded and the time spent between start of ischemia and onset of arrhythmias was measured. In addition, during ischemia and reperfusion the number of ventricular premature beats and bigemini and the duration of salvos and ventricular flutter and fibrillation were determined. The ischemic area was evaluated in all experiments and coronary flow was measured in Langendorff preparations. In the present experiments, no cardioprotective effects of Crataegus oxyacantha could be detected, neither in the heart in situ nor in the Langendorff preparations. Although the ischemic areas were identical, arrhythmias occurred even earlier in the Crataegus collectives than in the controls. Also the number and duration of ischemia and reperfusion induced arrhythmias tended to occur longer and more frequently in the Crataegus collectives, whilst coronary flow remained unchanged. The phenomenon that Crataegus rather aggravates than prevents arrhythmias may be reduced to a Crataegus induced increase in intracellular Ca(2+)-concentration proven true for the positive inotropic effects of Crataegus.

  19. The Relative Influences of Phosphometabolites and pH on Action Potential Morphology during Myocardial Reperfusion: A Simulation Study

    PubMed Central

    Roberts, Byron N.; Christini, David J.

    2012-01-01

    Myocardial ischemia-reperfusion (IR) injury represents a constellation of pathological processes that occur when ischemic myocardium experiences a restoration of perfusion. Reentrant arrhythmias, which represent a particularly lethal manifestation of IR injury, can result when ischemic tissue exhibits decreased excitability and/or changes of action potential duration (APD), conditions that precipitate unidirectional conduction block. Many of the cellular components that are involved with IR injury are modulated by pH and/or phosphometabolites such as ATP and phosphocreatine (PCr), all of which can be manipulated in vivo and potentially in the clinical setting. Using a mathematical model of the cardiomyocyte that we previously developed to study ischemia and reperfusion, we performed a series of simulations with the aim of determining whether pH- or phosphometabolite-related processes play a more significant role in generating changes in excitability and action potential morphology that are associated with the development of reentry. In our simulations, persistent shortening of APD, action potential amplitude (APA), and depolarization of the resting membrane potential were more severe when ATP and PCr availability were suppressed during reperfusion than when extracellular pH recovery was inhibited. Reduced phosphometabolite availability and pH recovery affected multiple ion channels and exchangers. Some of these effects were the result of direct modulation by phosphometabolites and/or acidosis, while others resulted from elevated sodium and calcium loads during reperfusion. In addition, increasing ATP and PCr availability during reperfusion was more beneficial in terms of increasing APD and APA than was increasing the amount of pH recovery. Together, these results suggest that therapies directed at increasing ATP and/or PCr availability during reperfusion may be more beneficial than perturbing pH recovery with regard to mitigating action potential changes that increase the likelihood of reentrant arrhythmias. PMID:23144801

  20. Leadership Development Through Peer-Facilitated Simulation in Nursing Education.

    PubMed

    Brown, Karen M; Rode, Jennifer L

    2018-01-01

    Baccalaureate nursing graduates must possess leadership skills, yet few opportunities exist to cultivate leadership abilities in a clinical environment. Peer-facilitated learning may increase the leadership skills of competence, self-confidence, self-reflection, and role modeling. Facilitating human patient simulation provides opportunities to develop leadership skills. With faculty supervision, senior baccalaureate students led small-group simulation experiences with sophomore and junior peers and then conducted subsequent debriefings. Quantitative and qualitative descriptive data allowed evaluation of students' satisfaction with this teaching innovation and whether the experience affected students' desire to take on leadership roles. Students expressed satisfaction with the peer-facilitated simulation experience and confidence in mastering the content while developing necessary skills for practice. Peer-facilitated simulation provides an opportunity for leadership development and learning. Study results can inform the development of nursing curricula to best develop the leadership skills of nursing students. [J Nurs Educ. 2018;57(1):53-57.]. Copyright 2018, SLACK Incorporated.

  1. Classification and Reporting of Potentially Proarrhythmic Common Genetic Variation in Long QT Syndrome Genetic Testing.

    PubMed

    Giudicessi, John R; Roden, Dan M; Wilde, Arthur A M; Ackerman, Michael J

    2018-02-06

    The acquired and congenital forms of long QT syndrome represent 2 distinct but clinically and genetically intertwined disorders of cardiac repolarization characterized by the shared final common pathway of QT interval prolongation and risk of potentially life-threatening arrhythmias. Over the past 2 decades, our understanding of the spectrum of genetic variation that (1) perturbs the function of cardiac ion channel macromolecular complexes and intracellular calcium-handling proteins, (2) underlies acquired/congenital long QT syndrome susceptibility, and (3) serves as a determinant of QT interval duration in the general population has grown exponentially. In turn, these molecular insights led to the development and increased utilization of clinically impactful genetic testing for congenital long QT syndrome. However, the widespread adoption and potential misinterpretation of the 2015 American College of Medical Genetics and Genomics variant classification and reporting guidelines may have contributed unintentionally to the reduced reporting of common genetic variants, with compelling epidemiological and functional evidence to support a potentially proarrhythmic role in patients with congenital and acquired long QT syndrome. As a result, some genetic testing reports may fail to convey the full extent of a patient's genetic susceptibility for a potentially life-threatening arrhythmia to the ordering healthcare professional. In this white paper, we examine the current classification and reporting (or lack thereof) of potentially proarrhythmic common genetic variants and investigate potential mechanisms to facilitate the reporting of these genetic variants without increasing the risk of diagnostic miscues. © 2018 American Heart Association, Inc.

  2. Evaluation of a New Shirt-Based Electrocardiogram Device for Cardiac Screening in Soccer Players: Comparative Study With Treadmill Ergospirometry

    PubMed Central

    Fabregat-Andres, Oscar; Munoz-Macho, Adolfo; Adell-Beltran, Guillermo; Ibanez-Catala, Xavier; Macia, Agustin; Facila, Lorenzo

    2014-01-01

    Background Prevention of cardiac events during competitive sports is fundamental. New technologies with remote monitoring systems integrated into clothing could facilitate the screening of heart disease. Our aim was to evaluate the feasibility of Nuubo system during a field stress test performed by soccer players, comparing results with treadmill ergospirometry as test reference. Methods Nineteen male professional soccer players (19.2 ± 1.6 years) were studied. Wireless electrocardiographic monitoring during a Yo-Yo intermittent recovery test level 1 in soccer field and subsequent analysis of arrhythmias were firstly performed. Subsequently, in a period no longer than 4 weeks, each player underwent cardiopulmonary exercise testing in hospital. Results During Yo-Yo test, electrocardiogram (ECG) signal was interpretable in 16 players (84.2%). In the other three players, ECG artifacts did not allow a proper analysis. Estimation of maximum oxygen consumption was comparable between two exercise tests (VO2 max 53.3 ± 2.4 vs. 53.7 ± 3.0 mL/kg/min for Yo-Yo test and ergometry respectively; intra-class correlation coefficient 0.84 (0.63 - 0.93), P < 0.001). No arrhythmias were detected in any player during both tests. Conclusions The use of Nuubo’s technology allows an accurate single-lead electrocardiographic recording and estimation of reliable performance variables during exercise testing in field, and provides a new perspective to cardiac remote monitoring in collective sports. PMID:28348705

  3. Electrophysiological Analysis of human Pluripotent Stem Cell-derived Cardiomyocytes (hPSC-CMs) Using Multi-electrode Arrays (MEAs).

    PubMed

    Sala, Luca; Ward-van Oostwaard, Dorien; Tertoolen, Leon G J; Mummery, Christine L; Bellin, Milena

    2017-05-12

    Cardiomyocytes can now be derived with high efficiency from both human embryonic and human induced-Pluripotent Stem Cells (hPSC). hPSC-derived cardiomyocytes (hPSC-CMs) are increasingly recognized as having great value for modeling cardiovascular diseases in humans, especially arrhythmia syndromes. They have also demonstrated relevance as in vitro systems for predicting drug responses, which makes them potentially useful for drug-screening and discovery, safety pharmacology and perhaps eventually for personalized medicine. This would be facilitated by deriving hPSC-CMs from patients or susceptible individuals as hiPSCs. For all applications, however, precise measurement and analysis of hPSC-CM electrical properties are essential for identifying changes due to cardiac ion channel mutations and/or drugs that target ion channels and can cause sudden cardiac death. Compared with manual patch-clamp, multi-electrode array (MEA) devices offer the advantage of allowing medium- to high-throughput recordings. This protocol describes how to dissociate 2D cell cultures of hPSC-CMs to small aggregates and single cells and plate them on MEAs to record their spontaneous electrical activity as field potential. Methods for analyzing the recorded data to extract specific parameters, such as the QT and the RR intervals, are also described here. Changes in these parameters would be expected in hPSC-CMs carrying mutations responsible for cardiac arrhythmias and following addition of specific drugs, allowing detection of those that carry a cardiotoxic risk.

  4. Feasibility, Process, and Outcomes of Cardiovascular Clinical Trial Data Sharing: A Reproduction Analysis of the SMART-AF Trial.

    PubMed

    Gay, Hawkins C; Baldridge, Abigail S; Huffman, Mark D

    2017-12-01

    Data sharing is as an expanding initiative for enhancing trust in the clinical research enterprise. To evaluate the feasibility, process, and outcomes of a reproduction analysis of the THERMOCOOL SMARTTOUCH Catheter for the Treatment of Symptomatic Paroxysmal Atrial Fibrillation (SMART-AF) trial using shared clinical trial data. A reproduction analysis of the SMART-AF trial was performed using the data sets, data dictionary, case report file, and statistical analysis plan from the original trial accessed through the Yale Open Data Access Project using the SAS Clinical Trials Data Transparency platform. SMART-AF was a multicenter, single-arm trial evaluating the effectiveness and safety of an irrigated, contact force-sensing catheter for ablation of drug refractory, symptomatic paroxysmal atrial fibrillation in 172 participants recruited from 21 sites between June 2011 and December 2011. Analysis of the data was conducted between December 2016 and April 2017. Effectiveness outcomes included freedom from atrial arrhythmias after ablation and proportion of participants without any arrhythmia recurrence over the 12 months of follow-up after a 3-month blanking period. Safety outcomes included major adverse device- or procedure-related events. The SMART AF trial participants' mean age was 58.7 (10.8) years, and 72% were men. The time from initial proposal submission to final analysis was 11 months. Freedom from atrial arrhythmias at 12 months postprocedure was similar compared with the primary study report (74.0%; 95% CI, 66.0-82.0 vs 76.4%; 95% CI, 68.7-84.1). The reproduction analysis success rate was higher than the primary study report (65.8%; 95% CI 56.5-74.2 vs 75.6%; 95% CI, 67.2-82.5). Adverse events were minimal and similar between the 2 analyses, but contact force range or regression models could not be reproduced. The feasibility of a reproduction analysis of the SMART-AF trial was demonstrated through an academic data-sharing platform. Data sharing can be facilitated through incentivizing collaboration, sharing statistical code, and creating more decentralized data sharing platforms with fewer restrictions to data access.

  5. Image integration into 3-dimensional-electro-anatomical mapping system facilitates safe ablation of ventricular arrhythmias originating from the aortic root and its vicinity.

    PubMed

    Jularic, Mario; Akbulak, Ruken Özge; Schäffer, Benjamin; Moser, Julia; Nuehrich, Jana; Meyer, Christian; Eickholt, Christian; Willems, Stephan; Hoffmann, Boris A

    2018-03-01

    During ablation in the vicinity of the coronary arteries establishing a safe distance from the catheter tip to the relevant vessels is mandatory and usually assessed by fluoroscopy alone. The aim of the study was to investigate the feasibility of an image integration module (IIM) for continuous monitoring of the distance of the ablation catheter tip to the main coronary arteries during ablation of ventricular arrhythmias (VA) originating in the sinus of valsalva (SOV) and the left ventricular summit part of which can be reached via the great cardiac vein (GCV). Of 129 patients undergoing mapping for outflow tract arrhythmias from June 2014 till October 2015, a total of 39 patients (52.4 ± 18.1 years, 17 female) had a source of origin in the SOV or the left ventricular summit. Radiofrequency (RF) ablation was performed when a distance of at least 5 mm could be demonstrated with IIM. A safe distance in at least one angiographic plane could be demonstrated in all patients with a source of origin in the SOV, whereas this was not possible in 50% of patients with earliest activation in the summit area. However, using the IIM a safe position at an adjacent site within the GCV could be obtained in three of these cases and successful RF ablation performed safely without any complications. Ablation was successful in 100% of patients with an origin in the SOV, whereas VAs originating from the left ventricular summit could be abolished completely in only 60% of cases. Image integration combining electroanatomical mapping and fluoroscopy allows assessment of the safety of a potential ablation site by continuous real-time monitoring of the spatial relations of the catheter tip to the coronary vessels prior to RF application. It aids ablation in anatomically complex regions like the SOV or the ventricular summit providing biplane angiograms merged into the three-dimensional electroanatomical map. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.

  6. Recurrent ventricular arrhythmias complicating myocardial infarction in the presence of phaeochromocytoma.

    PubMed Central

    McNeill, A J; Adgey, A A; Wilson, C

    1992-01-01

    After an acute myocardial infarction a 49 year old man developed late recurrent severe ventricular arrhythmias coincident with transient hypertensive episodes. A phaeochromocytoma was diagnosed on the basis of the urinary concentration of catecholamines and computerised tomography of the adrenal glands. After stabilisation of his cardiac rhythm and blood pressure with alpha and beta adrenergic blockade and anti-arrhythmic treatment the right adrenal gland, which contained the tumour, was successfully resected. The diagnosis of a phaeochromocytoma should be considered when recurrent ventricular arrhythmias are associated with intermittent hypertension after myocardial infarction. PMID:1739535

  7. Cascade Classification with Adaptive Feature Extraction for Arrhythmia Detection.

    PubMed

    Park, Juyoung; Kang, Mingon; Gao, Jean; Kim, Younghoon; Kang, Kyungtae

    2017-01-01

    Detecting arrhythmia from ECG data is now feasible on mobile devices, but in this environment it is necessary to trade computational efficiency against accuracy. We propose an adaptive strategy for feature extraction that only considers normalized beat morphology features when running in a resource-constrained environment; but in a high-performance environment it takes account of a wider range of ECG features. This process is augmented by a cascaded random forest classifier. Experiments on data from the MIT-BIH Arrhythmia Database showed classification accuracies from 96.59% to 98.51%, which are comparable to state-of-the art methods.

  8. Ventricular fibrillation development following atrial fibrillation after the ingestion of sildenaphil in a patient with Wolff-Parkinson-White syndrome

    PubMed Central

    Inci, Sinan; Izgu, Ibrahim; Aktas, Halil; Dogan, Pinar; Dogan, Ali

    2015-01-01

    Summary Complications in the accessory pathway in Wolff-Parkinson-White (WPW) syndrome could cause different clinical conditions by inducing different arrhythmias. Atrial fibrillation (AF) is one of these arrhythmias and is important as it causes life-threatening arrhythmias. It is known that some drugs, underlying cardiac diseases, and the number of accessory pathways, cause a predisposition to this condition. In the current report, we presented a patient with WPW who was admitted to the emergency department with AF, wide QRS and a rapid ventricular response that progressed to ventricular fibrillation. PMID:26361569

  9. Ventricular fibrillation development following atrial fibrillation after the ingestion of sildenaphil in a patient with Wolff-Parkinson-White syndrome.

    PubMed

    Inci, Sinan; Izgu, Ibrahim; Aktas, Halil; Dogan, Pinar; Dogan, Ali

    2015-08-01

    Complications in the accessory pathway in Wolff-Parkinson-White (WPW) syndrome could cause different clinical conditions by inducing different arrhythmias. Atrial fibrillation (AF) is one of these arrhythmias and is important as it causes life-threatening arrhythmias. It is known that some drugs, underlying cardiac diseases, and the number of accessory pathways, cause a predisposition to this condition. In the current report, we presented a patient with WPW who was admitted to the emergency department with AF, wide QRS and a rapid ventricular response that progressed to ventricular fibrillation.

  10. Treatment of cardiac arrhythmias in a mouse model of Rett syndrome with Na+-channel-blocking antiepileptic drugs

    PubMed Central

    Herrera, José A.; Ward, Christopher S.; Pitcher, Meagan R.; Percy, Alan K.; Skinner, Steven; Kaufmann, Walter E.; Glaze, Daniel G.; Wehrens, Xander H. T.; Neul, Jeffrey L.

    2015-01-01

    One quarter of deaths associated with Rett syndrome (RTT), an X-linked neurodevelopmental disorder, are sudden and unexpected. RTT is associated with prolonged QTc interval (LQT), and LQT-associated cardiac arrhythmias are a potential cause of unexpected death. The standard of care for LQT in RTT is treatment with β-adrenergic antagonists; however, recent work indicates that acute treatment of mice with RTT with a β-antagonist, propranolol, does not prevent lethal arrhythmias. In contrast, acute treatment with the Na+ channel blocker phenytoin prevented arrhythmias. Chronic dosing of propranolol may be required for efficacy; therefore, we tested the efficacy of chronic treatment with either propranolol or phenytoin on RTT mice. Phenytoin completely abolished arrhythmias, whereas propranolol showed no benefit. Surprisingly, phenytoin also normalized weight and activity, but worsened breathing patterns. To explore the role of Na+ channel blockers on QT in people with RTT, we performed a retrospective analysis of QT status before and after Na+ channel blocker antiepileptic therapies. Individuals with RTT and LQT significantly improved their QT interval status after being started on Na+ channel blocker antiepileptic therapies. Thus, Na+ channel blockers should be considered for the clinical management of LQT in individuals with RTT. PMID:25713300

  11. Cholinesterase inhibition reduces arrhythmias in asymptomatic Chagas disease.

    PubMed

    Castro, Renata R T; Porphirio, Graciema; Xavier, Sergio S; Moraes, Ruy S; Ferlin, Elton L; Ribeiro, Jorge P; da Nóbrega, Antonio C L

    2017-10-01

    Parasympathetic dysfunction may play a role in the genesis of arrhythmias in Chagas disease. This study evaluates the acute effects of pyridostigmine (PYR), a reversible cholinesterase inhibitor, on the occurrence of arrhythmias in patients with Chagas cardiac disease. Following a double-blind, randomized, placebo-controlled, cross-over protocol, 17 patients (age 50±2 years) with Chagas cardiac disease type B underwent 24-hour Holter recordings after oral administration of either pyridostigmine bromide (45 mg, 3 times/day) or placebo (PLA). Pyridostigmine reduced the 24-hours incidence (median [25%-75%]) of premature ventricular beats-PLA: 2998 (1920-4870), PYR: 2359 (940-3253), P=.044; ventricular couplets-PLA: 84 (15-159), PYR: 33 (6-94), P=.046. Although the total number of nonsustained ventricular tachycardia in the entire group was not different (P=.19) between PLA (1 [0-8]) and PYR (0 [0-4]), there were fewer episodes under PYR in 72% of the patients presenting this type of arrhythmia (P=.033). Acute administration of pyridostigmine reduced the incidence of nonsustained ventricular arrhythmias in patients with Chagas cardiac disease. Further studies that address the use of pyridostigmine by patients with Chagas cardiac disease under a more prolonged follow-up are warranted. © 2017 John Wiley & Sons Ltd.

  12. Link between Hypoglycemia and Cardiac Arrhythmias: An Answer to Why Tight Glycemic Control May Increase Mortality in ...

    MedlinePlus

    ... Cardiac Arrhythmias: An Answer to Why Tight Glycemic Control May Increase Mortality in People with Diabetes and ... funded clinical trial that examined whether tight glycemic control could reduce cardiovascular events in people with type ...

  13. User-initialized active contour segmentation and golden-angle real-time cardiovascular magnetic resonance enable accurate assessment of LV function in patients with sinus rhythm and arrhythmias.

    PubMed

    Contijoch, Francisco; Witschey, Walter R T; Rogers, Kelly; Rears, Hannah; Hansen, Michael; Yushkevich, Paul; Gorman, Joseph; Gorman, Robert C; Han, Yuchi

    2015-05-21

    Data obtained during arrhythmia is retained in real-time cardiovascular magnetic resonance (rt-CMR), but there is limited and inconsistent evidence to show that rt-CMR can accurately assess beat-to-beat variation in left ventricular (LV) function or during an arrhythmia. Multi-slice, short axis cine and real-time golden-angle radial CMR data was collected in 22 clinical patients (18 in sinus rhythm and 4 patients with arrhythmia). A user-initialized active contour segmentation (ACS) software was validated via comparison to manual segmentation on clinically accepted software. For each image in the 2D acquisitions, slice volume was calculated and global LV volumes were estimated via summation across the LV using multiple slices. Real-time imaging data was reconstructed using different image exposure times and frame rates to evaluate the effect of temporal resolution on measured function in each slice via ACS. Finally, global volumetric function of ectopic and non-ectopic beats was measured using ACS in patients with arrhythmias. ACS provides global LV volume measurements that are not significantly different from manual quantification of retrospectively gated cine images in sinus rhythm patients. With an exposure time of 95.2 ms and a frame rate of > 89 frames per second, golden-angle real-time imaging accurately captures hemodynamic function over a range of patient heart rates. In four patients with frequent ectopic contractions, initial quantification of the impact of ectopic beats on hemodynamic function was demonstrated. User-initialized active contours and golden-angle real-time radial CMR can be used to determine time-varying LV function in patients. These methods will be very useful for the assessment of LV function in patients with frequent arrhythmias.

  14. Influence of ambient temperature and diurnal temperature range on incidence of cardiac arrhythmias

    NASA Astrophysics Data System (ADS)

    Kim, Jayeun; Kim, Ho

    2017-03-01

    We investigated the association between ambient temperature and diurnal temperature range (DTR) and the exacerbation of arrhythmia symptoms, using data from 31,629 arrhythmia-related emergency department (ED) visits in Seoul, Korea. Linear regression analyses with allowances for over-dispersion were applied to temperature variables and ED visits, adjusted for various environmental factors. The effects were expressed as percentage changes in the risk of arrhythmia-related ED visits up to 5 days later, with 95 % confidence intervals (CI), per 1 °C increase in DTR and 1 °C decrease in mean temperature. The overall risk of ED visits increased by 1.06 % (95 % CI 0.39 %, 1.73 %) for temperature and by 1.84 % (0.34, 3.37 %) for DTR. A season-specific effect was detected for temperature during both fall (1.18 % [0.01, 2.37 %]) and winter (0.87 % [0.07, 1.67 %]), and for DTR during spring (3.76 % [0.34, 7.29 %]). Females were more vulnerable, with 1.57 % [0.56, 2.59 %] and 3.84 % [1.53, 6.20 %] for the changes in temperature and DTR, respectively. An age-specific effect was detected for DTR, with 3.13 % [0.95, 5.36 %] for age ≥ 65 years, while a greater increased risk with temperature decrease was observed among those aged <65 (1.08 % [0.17, 2.00 %]) than among those aged ≥65 (1.02 % [0.06, 1.99 %]). Cardiac arrest was inversely related with temperature (1.61 % [0.46, 2.79 %]), while other cardiac arrhythmias depended more on the change in DTR (4.72 % [0.37, 9.26 %]). These findings provide evidence that low-temperature and elevated DTR influence the occurrence of arrhythmia exacerbations or symptoms, suggesting a possible strategy for reducing risk by encouraging vulnerable populations to minimize exposure.

  15. α-Adrenoceptor blockade modifies neurally induced atrial arrhythmias

    PubMed Central

    Richer, Louis-Philippe; Vinet, Alain; Kus, Teresa; Cardinal, René; Ardell, Jeffrey L.; Armour, John Andrew

    2008-01-01

    Our objective was to determine whether neuronally induced atrial arrhythmias can be modified by α-adrenergic receptor blockade. In 30 anesthetized dogs, trains of five electrical stimuli (1 mA; 1 ms) were delivered immediately after the P wave of the ECG to mediastinal nerves associated with the superior vena cava. Regional atrial electrical events were monitored with 191 atrial unipolar electrodes. Mediastinal nerve sites were identified that reproducibly initiated atrial arrhythmias. These sites were then restimulated following 1 h (time control, n = 6), or the intravenous administration of naftopidil (α1-adrenergic blocker: 0.2 mg/kg, n = 6), yohimbine (α2-adrenergic blocker: 1 mg/kg, n = 6) or both (n = 8). A ganglionic blocker (hexamethonium: 1 mg/kg) was tested in four dogs. Stimulation of mediastinal nerves sites consistently elicited atrial tachyarrhythmias. Repeat stimulation after 1 h in the time-control group exerted a 19% decrease of the sites still able to induce atrial tachyarrhythmias. Hexamethonium inactivated 78% of the previously active sites. Combined α-adrenoceptor blockade inactivated 72% of the previously active sites. Bradycardia responses induced by mediastinal nerve stimulation were blunted by hexamethonium, but not by α1,2-adrenergic blockade. Naftopidil or yohimbine alone eliminated atrial arrhythmia induction from 31% and 34% of the sites (similar to time control). We conclude that heterogeneous activation of the intrinsic cardiac nervous system results in atrial arrhythmias that involve intrinsic cardiac neuronal α-adrenoceptors. In contrast to the global suppression exerted by hexamethonium, we conclude that α-adrenoceptor blockade targets intrinsic cardiac local circuit neurons involved in arrhythmia formation and not the flow-through efferent projections of the cardiac nervous system. PMID:18716036

  16. Alpha-adrenoceptor blockade modifies neurally induced atrial arrhythmias.

    PubMed

    Richer, Louis-Philippe; Vinet, Alain; Kus, Teresa; Cardinal, René; Ardell, Jeffrey L; Armour, John Andrew

    2008-10-01

    Our objective was to determine whether neuronally induced atrial arrhythmias can be modified by alpha-adrenergic receptor blockade. In 30 anesthetized dogs, trains of five electrical stimuli (1 mA; 1 ms) were delivered immediately after the P wave of the ECG to mediastinal nerves associated with the superior vena cava. Regional atrial electrical events were monitored with 191 atrial unipolar electrodes. Mediastinal nerve sites were identified that reproducibly initiated atrial arrhythmias. These sites were then restimulated following 1 h (time control, n = 6), or the intravenous administration of naftopidil (alpha(1)-adrenergic blocker: 0.2 mg/kg, n = 6), yohimbine (alpha(2)-adrenergic blocker: 1 mg/kg, n = 6) or both (n = 8). A ganglionic blocker (hexamethonium: 1 mg/kg) was tested in four dogs. Stimulation of mediastinal nerves sites consistently elicited atrial tachyarrhythmias. Repeat stimulation after 1 h in the time-control group exerted a 19% decrease of the sites still able to induce atrial tachyarrhythmias. Hexamethonium inactivated 78% of the previously active sites. Combined alpha-adrenoceptor blockade inactivated 72% of the previously active sites. Bradycardia responses induced by mediastinal nerve stimulation were blunted by hexamethonium, but not by alpha(1,2)-adrenergic blockade. Naftopidil or yohimbine alone eliminated atrial arrhythmia induction from 31% and 34% of the sites (similar to time control). We conclude that heterogeneous activation of the intrinsic cardiac nervous system results in atrial arrhythmias that involve intrinsic cardiac neuronal alpha-adrenoceptors. In contrast to the global suppression exerted by hexamethonium, we conclude that alpha-adrenoceptor blockade targets intrinsic cardiac local circuit neurons involved in arrhythmia formation and not the flow-through efferent projections of the cardiac nervous system.

  17. Added value of cardiac magnetic resonance in etiological diagnosis of ventricular arrhythmias.

    PubMed

    Cabanelas, Nuno; Vidigal Ferreira, Maria João; Donato, Paulo; Gaspar, António; Pinto, Joana; Caseiro-Alves, Filipe; Providência, Luís Augusto

    2013-10-01

    Cardiac magnetic resonance (CMR) imaging is increasingly important in the diagnostic work-up of a wide range of heart diseases, including those with arrhythmogenic potential. To assess the added value of CMR in etiological diagnosis of ventricular arrhythmias after an inconclusive conventional investigation. Patients undergoing CMR between 2005 and 2011 for investigation of ventricular arrhythmias were included (n=113). All had documented arrhythmias. Those with a definite diagnosis from a previous investigation and those with evidence of coronary artery disease (acute coronary syndrome, typical angina symptoms, increase in biomarkers or positive stress test) were excluded. CMR results were considered relevant when they fulfilled diagnostic criteria. Of the 113 patients, 57.5% were male and mean age was 41.7 ± 16.2 years. Regarding the initial arrhythmia, 38.1% had ventricular fibrillation/sustained ventricular tachycardia (VF/VT) and 61.9% had less complex ventricular ectopy. CMR imaging showed criteria of a specific diagnosis in 42.5% of patients, was totally normal in 36.3%, and showed non-specific alterations in the remainder. In VF/VT patients, specific criteria were found in 60.4%, and in 31.4% of those with less complex ectopy. The most frequent diagnoses were arrhythmogenic right ventricular dysplasia, ventricular non-compaction and myopericarditis. It is worth noting that, although there was no evidence of previous coronary artery disease, 6.2% of patients had a late gadolinium enhancement distribution pattern compatible with myocardial infarction. CMR gives additional and important information in the diagnostic work-up of ventricular arrhythmias after an inconclusive initial investigation. The proportion of patients with diagnostic criteria was 42.5% (60.0% in those with VF/VT), and CMR was completely normal in 36.6%. Copyright © 2012 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.

  18. Implantable Defibrillators for Secondary Prevention of Sudden Cardiac Death in Cardiac Surgery Patients With Perioperative Ventricular Arrhythmias

    PubMed Central

    Nageh, Maged F.; Kim, John J.; Chen, Lie‐Hong; Yao, Janis F.

    2014-01-01

    Background Randomized studies of implantable cardioverter defibrillators (ICD) have excluded sudden cardiac death survivors who had revascularization before or after an arrhythmic event. To evaluate the role of ICD and the effects of clinical variables including degree of revascularization, we studied cardiac surgery patients who had an ICD implanted for sustained perioperative ventricular arrhythmias. Methods and Results The electronic database for Southern California Kaiser Foundation hospitals was searched for patients who had cardiac surgery between 1999 and 2005 and an ICD implanted within 3 months of surgery. One hundred sixty‐four patients were identified; 93/164 had an ICD for sustained pre‐ or postoperative ventricular tachycardia or fibrillation requiring resuscitation. Records were reviewed for the following: presenting arrhythmia, ejection fraction, and degree of revascularization. The primary end point was total mortality (TM) and/or appropriate ICD therapy (ICD‐T), and secondary end points are TM and ICD‐T. During the mean follow up of 49 months, the primary endpoint of TM+ICD‐T and individual end points of TM and ICD‐T were observed in 52 (56%), 35 (38%), and 28 (30%) patients, respectively, with 55% of TM, and 23% of ICD‐T occurring within 2 years of implant. In multivariate risk analysis, none of the following was associated with any of the end points: incomplete revascularization, presenting ventricular arrhythmia, and timing of arrhythmias. Conclusion Our data supports the recent guidelines for ICD in this cohort of patients, as the presence of irreversible substrate and triggers of ventricular arrhythmias, cannot be reliably excluded even with complete revascularization. Further studies are needed to understand this complex group of patients. PMID:25146702

  19. Amiodarone in the treatment of refractory supraventricular and ventricular arrhythmias

    PubMed Central

    Wheeler, P. J.; Ingram, D. V.; Puritz, R.; Chamberlain, D. A.

    1979-01-01

    Amiodarone is an antiarrhythmic agent unrelated to other drugs in current use. It has been little used in Britain, and no formal clinical trials have been possible because the drug has not been licensed by the Committee on Safety of Medicines. Nevertheless it has unique properties which can be valuable in the treatment of a wide spectrum of arrhythmias, particularly supraventricular tachycardias. Amiodarone has a slow onset of action and is cumulative. A sustained action is therefore achieved without the need for frequent maintenance dosage. Fifty patients have been treated with amiodarone in maintenance doses ranging from 200 mg on alternate days to 200 mg twice daily either alone, or in combination with conventional therapy. All were resistant to conventional therapy alone or could not be treated with usual agents because of unwanted drug effects. Of 27 patients with supraventricular arrhythmias, 18 were completely controlled and the other 9 were markedly improved. Six of 8 patients with recurrent life-threatening ventricular arrhythmias were well controlled symptomatically. Results were predictably less satisfactory in 15 high risk post-infarction patients with malignant arrhythmias and severe myocardial damage, but 6 were probably improved as a result of amiodarone. All patients on maintenance therapy for 3 months or more developed corneal microdeposits. None has any visual symptoms or other ocular defect, and treatment has not been curtailed as a result of this well recognized effect which is believed to be reversible and benign. Amiodarone can control patients with otherwise refractory arrhythmias including some which are life-threatening. Formal clinical trials are needed to define accurately its future role in the prevention and treatment of serious rhythm disorders of the heart. PMID:432163

  20. Electrocardiogram changes and atrial arrhythmias in individuals carrying sodium channel SCN5A D1275N mutation.

    PubMed

    Vanninen, Sari U M; Nikus, Kjell; Aalto-Setälä, Katriina

    2017-09-01

    The cardiac sodium channel SCN5A regulates atrioventricular and ventricular depolarization as well as cardiac conduction. Patients with cardiac electrical abnormalities have an increased risk of sudden cardiac death (SCD) and cardio-embolic stroke. Optimal management of cardiac disease includes the understanding of association between the causative mutations and the clinical phenotype. A 12-lead electrocardiogram (ECG) is an easy and inexpensive tool for finding risk patients. A blood sample for DNA extraction was obtained in a Finnish family with 43 members; systematic 12-lead ECG analysis was performed in 13 of the family members carrying an SCN5A D1275N mutation. Conduction defects and supraventricular arrhythmias, including atrial fibrillation/flutter, atrioventricular nodal re-entry tachycardia (AVNRT) and junctional rhythm were searched for. Five (38%) mutation carriers had fascicular or bundle branch block, 10 had atrial arrhythmias; no ventricular arrhythmias were found. Notching of the R- and S waves - including initial QRS fragmentation - and prolonged S-wave upstroke were present in all the affected family members. Notably, four (31%) affected family members had a stroke before the age of 31 and two experienced premature death. A 12-lead ECG can be used to predict arrhythmias in SCN5A D1275N mutation carriers. Key messages The 12-lead ECG may reveal cardiac abnormalities even before clinical symptoms occur. Specific ECG findings - initial QRS fragmentation, prolonged S-wave upstroke as well as supraventricular arrhythmias - were frequently encountered in all SCN5A D1257N mutation carriers. ECG follow-up is recommended for all SCN5A D1275N mutation carriers.

  1. Epac2-Rap1 Signaling Regulates Reactive Oxygen Species Production and Susceptibility to Cardiac Arrhythmias

    PubMed Central

    Yang, Zhaokang; Kirton, Hannah M.; Al-Owais, Moza; Thireau, Jérôme; Richard, Sylvain; Peers, Chris

    2017-01-01

    Abstract Aims: In the heart, β1-adrenergic signaling involves cyclic adenosine monophosphate (cAMP) acting via both protein kinase-A (PKA) and exchange protein directly activated by cAMP (Epac): a guanine nucleotide exchange factor for the small GTPase Rap1. Inhibition of Epac-Rap1 signaling has been proposed as a therapeutic strategy for both cancer and cardiovascular disease. However, previous work suggests that impaired Rap1 signaling may have detrimental effects on cardiac function. The aim of the present study was to investigate the influence of Epac2-Rap1 signaling on the heart using both in vivo and in vitro approaches. Results: Inhibition of Epac2 signaling induced early afterdepolarization arrhythmias in ventricular myocytes. The underlying mechanism involved an increase in mitochondrial reactive oxygen species (ROS) and activation of the late sodium current (INalate). Arrhythmias were blocked by inhibition of INalate or the mitochondria-targeted antioxidant, mitoTEMPO. In vivo, inhibition of Epac2 caused ventricular tachycardia, torsades de pointes, and sudden death. The in vitro and in vivo effects of Epac2 inhibition were mimicked by inhibition of geranylgeranyltransferase-1, which blocks interaction of Rap1 with downstream targets. Innovation: Our findings show for the first time that Rap1 acts as a negative regulator of mitochondrial ROS production in the heart and that impaired Epac2-Rap1 signaling causes arrhythmias due to ROS-dependent activation of INalate. This has implications for the use of chemotherapeutics that target Epac2-Rap1 signaling. However, selective inhibition of INalate provides a promising strategy to prevent arrhythmias caused by impaired Epac2-Rap1 signaling. Conclusion: Epac2-Rap1 signaling attenuates mitochondrial ROS production and reduces myocardial arrhythmia susceptibility. Antioxid. Redox Signal. 27, 117–132. PMID:27649969

  2. Incidence of cardiac arrhythmias in asymptomatic hereditary hemochromatosis subjects with C282Y homozygosity.

    PubMed

    Shizukuda, Yukitaka; Tripodi, Dorothy J; Zalos, Gloria; Bolan, Charles D; Yau, Yu-Ying; Leitman, Susan F; Waclawiw, Myron A; Rosing, Douglas R

    2012-03-15

    It is not well known whether systemic iron overload per se in hereditary hemochromatosis (HH) is associated with cardiac arrhythmias before other signs and symptoms of cardiovascular disease occur. In the present study, we examined the incidence of cardiac arrhythmia in cardiac asymptomatic subjects with HH (New York Heart Association functional class I) and compared it to that in age- and gender-matched normal volunteers. The 42 subjects with HH and the 19 normal control subjects were recruited through the National Heart, Lung, and Blood Institute-sponsored "Heart Study of Hemochromatosis." They completed 48-hour Holter electrocardiography ambulatory monitoring at the baseline evaluation. The subjects with HH were classified as newly diagnosed (group A) and chronically treated (group B) subjects. All subjects with HH had C282Y homozygosity, and the normal volunteers lacked any HFE gene mutations known to cause HH. Although statistically insignificant, the incidence of ventricular and supraventricular ectopy tended to be greater in the combined HH groups than in the controls. Supraventricular ectopy was more frequently noted in group B compared to in the controls (ectopy rate per hour 11.1 ± 29.9 vs 1.5 ± 3.5, p < 0.05, using the Kruskal-Wallis test). No examples of heart block, other than first-degree atrioventricular node block, were seen in any of the subjects. The incidence of cardiac arrhythmias was not significantly reduced after 6 months of intensive iron removal therapy in the group A subjects. No life-threatening arrhythmias were observed in our subjects with HH. In conclusion, our data suggest that the incidence of cardiac arrhythmias is, at most, marginally increased in asymptomatic subjects with HH. A larger clinical study is warranted to further clarify our observation. Published by Elsevier Inc.

  3. Random forests ensemble classifier trained with data resampling strategy to improve cardiac arrhythmia diagnosis.

    PubMed

    Ozçift, Akin

    2011-05-01

    Supervised classification algorithms are commonly used in the designing of computer-aided diagnosis systems. In this study, we present a resampling strategy based Random Forests (RF) ensemble classifier to improve diagnosis of cardiac arrhythmia. Random forests is an ensemble classifier that consists of many decision trees and outputs the class that is the mode of the class's output by individual trees. In this way, an RF ensemble classifier performs better than a single tree from classification performance point of view. In general, multiclass datasets having unbalanced distribution of sample sizes are difficult to analyze in terms of class discrimination. Cardiac arrhythmia is such a dataset that has multiple classes with small sample sizes and it is therefore adequate to test our resampling based training strategy. The dataset contains 452 samples in fourteen types of arrhythmias and eleven of these classes have sample sizes less than 15. Our diagnosis strategy consists of two parts: (i) a correlation based feature selection algorithm is used to select relevant features from cardiac arrhythmia dataset. (ii) RF machine learning algorithm is used to evaluate the performance of selected features with and without simple random sampling to evaluate the efficiency of proposed training strategy. The resultant accuracy of the classifier is found to be 90.0% and this is a quite high diagnosis performance for cardiac arrhythmia. Furthermore, three case studies, i.e., thyroid, cardiotocography and audiology, are used to benchmark the effectiveness of the proposed method. The results of experiments demonstrated the efficiency of random sampling strategy in training RF ensemble classification algorithm. Copyright © 2011 Elsevier Ltd. All rights reserved.

  4. Divergent effects of adrenaline in human induced pluripotent stem cell-derived cardiomyocytes obtained from hypertrophic cardiomyopathy

    PubMed Central

    Prajapati, Chandra

    2018-01-01

    ABSTRACT Hypertrophic cardiomyopathy (HCM) is a common inherited cardiac disease that affects the heart muscle with diverse clinical outcomes. HCM can cause sudden cardiac death (SCD) during or immediately after mild to rigorous physical activity in young patients. However, the mechanism causing SCD as a result of exercise remains unknown, but exercise-induced ventricular arrhythmias are thought to be responsible for this fatal consequence. To understand the disease mechanism behind HCM in a better way, we generated patient-specific induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs) from HCM patients carrying either the MYBPC3-Gln1061X or TPM1-Asp175Asn mutation. We extensively investigated the effects of low to high concentrations of adrenaline on action potential characteristics, and the occurrence of arrhythmias in the presence of various concentrations of adrenaline and in wash-out condition. We classified and quantified different types of arrhythmias observed in hiPSC-CMs, and found that the occurrence of arrhythmias was dependent on concentrations of adrenaline and positions of mutations in genes causing HCM. In addition, we observed ventricular tachycardia types of arrhythmias in hiPSC-CMs carrying the TPM1-Asp175Asn mutation. We additionally examined the antiarrhythmic potency of bisoprolol in HCM-specific hiPSC-CMs. However, bisoprolol could not reduce the occurrence of arrhythmias during administration or during the wash-out condition of adrenaline in HCM-specific hiPSC-CMs. Our study demonstrates hiPSC-CMs as a promising tool for studying HCM. The experimental design used in this study could be suitable and beneficial for studying other components and drugs related to cardiac disease in general. PMID:29361520

  5. Applications of the Petri net to simulate, test, and validate the performance and safety of complex, heterogeneous, multi-modality patient monitoring alarm systems.

    PubMed

    Sloane, E B; Gelhot, V

    2004-01-01

    This research is motivated by the rapid pace of medical device and information system integration. Although the ability to interconnect many medical devices and information systems may help improve patient care, there is no way to detect if incompatibilities between one or more devices might cause critical events such as patient alarms to go unnoticed or cause one or more of the devices to become stuck in a disabled state. Petri net tools allow automated testing of all possible states and transitions between devices and/or systems to detect potential failure modes in advance. This paper describes an early research project to use Petri nets to simulate and validate a multi-modality central patient monitoring system. A free Petri net tool, HPSim, is used to simulate two wireless patient monitoring networks: one with 44 heart monitors and a central monitoring system and a second version that includes an additional 44 wireless pulse oximeters. In the latter Petri net simulation, a potentially dangerous heart arrhythmia and pulse oximetry alarms were detected.

  6. Behavioral and Cardiovascular Responses to Frustration During Simulated Driving Tasks in Young Adults With and Without Attention Disorder Symptoms

    PubMed Central

    Oliver, Michele L.; Nigg, Joel T.; Cassavaugh, Nicholas D.; Backs, Richard W.

    2015-01-01

    Objective The present study examined the role of negative emotions on driving performance in relation to ADHD, by comparing young adults scoring high on measures of ADHD (n = 20) with a control group (n = 22). Method The authors used cardiorespiratory physiological measures, simulated driving behavior, and self-report to examine how participants with high and low ADHD symptoms responded to frustration and to determine how frustration affected simulated driving performance. Results Groups did not differ in operational driving skills, but participants with high ADHD symptoms reported more frustration and exhibited more impairment at the tactical level of driving performance than the controls. There was significant suppression of respiratory sinus arrhythmia from resting baseline during tasks, but it did not differ between groups during driving. Conclusion This article proposes that remedial driver training for ADHD populations should focus more on the control of negative emotions rather than on attention or fundamental driving skills. PMID:21490175

  7. Classification of arrhythmia using hybrid networks.

    PubMed

    Haseena, Hassan H; Joseph, Paul K; Mathew, Abraham T

    2011-12-01

    Reliable detection of arrhythmias based on digital processing of Electrocardiogram (ECG) signals is vital in providing suitable and timely treatment to a cardiac patient. Due to corruption of ECG signals with multiple frequency noise and presence of multiple arrhythmic events in a cardiac rhythm, computerized interpretation of abnormal ECG rhythms is a challenging task. This paper focuses a Fuzzy C- Mean (FCM) clustered Probabilistic Neural Network (PNN) and Multi Layered Feed Forward Network (MLFFN) for the discrimination of eight types of ECG beats. Parameters such as fourth order Auto Regressive (AR) coefficients along with Spectral Entropy (SE) are extracted from each ECG beat and feature reduction has been carried out using FCM clustering. The cluster centers form the input of neural network classifiers. The extensive analysis of Massachusetts Institute of Technology- Beth Israel Hospital (MIT-BIH) arrhythmia database shows that FCM clustered PNNs is superior in cardiac arrhythmia classification than FCM clustered MLFFN with an overall accuracy of 99.05%, 97.14%, respectively.

  8. A Real-Time Cardiac Arrhythmia Classification System with Wearable Sensor Networks

    PubMed Central

    Hu, Sheng; Wei, Hongxing; Chen, Youdong; Tan, Jindong

    2012-01-01

    Long term continuous monitoring of electrocardiogram (ECG) in a free living environment provides valuable information for prevention on the heart attack and other high risk diseases. This paper presents the design of a real-time wearable ECG monitoring system with associated cardiac arrhythmia classification algorithms. One of the striking advantages is that ECG analog front-end and on-node digital processing are designed to remove most of the noise and bias. In addition, the wearable sensor node is able to monitor the patient's ECG and motion signal in an unobstructive way. To realize the real-time medical analysis, the ECG is digitalized and transmitted to a smart phone via Bluetooth. On the smart phone, the ECG waveform is visualized and a novel layered hidden Markov model is seamlessly integrated to classify multiple cardiac arrhythmias in real time. Experimental results demonstrate that the clean and reliable ECG waveform can be captured in multiple stressed conditions and the real-time classification on cardiac arrhythmia is competent to other workbenches. PMID:23112746

  9. Detection of Life Threatening Ventricular Arrhythmia Using Digital Taylor Fourier Transform.

    PubMed

    Tripathy, Rajesh K; Zamora-Mendez, Alejandro; de la O Serna, José A; Paternina, Mario R Arrieta; Arrieta, Juan G; Naik, Ganesh R

    2018-01-01

    Accurate detection and classification of life-threatening ventricular arrhythmia episodes such as ventricular fibrillation (VF) and rapid ventricular tachycardia (VT) from electrocardiogram (ECG) is a challenging problem for patient monitoring and defibrillation therapy. This paper introduces a novel method for detection and classification of life-threatening ventricular arrhythmia episodes. The ECG signal is decomposed into various oscillatory modes using digital Taylor-Fourier transform (DTFT). The magnitude feature and a novel phase feature namely the phase difference (PD) are evaluated from the mode Taylor-Fourier coefficients of ECG signal. The least square support vector machine (LS-SVM) classifier with linear and radial basis function (RBF) kernels is employed for detection and classification of VT vs. VF, non-shock vs. shock and VF vs. non-VF arrhythmia episodes. The accuracy, sensitivity, and specificity values obtained using the proposed method are 89.81, 86.38, and 93.97%, respectively for the classification of Non-VF and VF episodes. Comparison with the performance of the state-of-the-art features demonstrate the advantages of the proposition.

  10. Detection of Life Threatening Ventricular Arrhythmia Using Digital Taylor Fourier Transform

    PubMed Central

    Tripathy, Rajesh K.; Zamora-Mendez, Alejandro; de la O Serna, José A.; Paternina, Mario R. Arrieta; Arrieta, Juan G.; Naik, Ganesh R.

    2018-01-01

    Accurate detection and classification of life-threatening ventricular arrhythmia episodes such as ventricular fibrillation (VF) and rapid ventricular tachycardia (VT) from electrocardiogram (ECG) is a challenging problem for patient monitoring and defibrillation therapy. This paper introduces a novel method for detection and classification of life-threatening ventricular arrhythmia episodes. The ECG signal is decomposed into various oscillatory modes using digital Taylor-Fourier transform (DTFT). The magnitude feature and a novel phase feature namely the phase difference (PD) are evaluated from the mode Taylor-Fourier coefficients of ECG signal. The least square support vector machine (LS-SVM) classifier with linear and radial basis function (RBF) kernels is employed for detection and classification of VT vs. VF, non-shock vs. shock and VF vs. non-VF arrhythmia episodes. The accuracy, sensitivity, and specificity values obtained using the proposed method are 89.81, 86.38, and 93.97%, respectively for the classification of Non-VF and VF episodes. Comparison with the performance of the state-of-the-art features demonstrate the advantages of the proposition.

  11. Nerve conduction studies are safe in patients with central venous catheters.

    PubMed

    London, Zachary N; Mundwiler, Andrew; Oral, Hakan; Gallagher, Gary W

    2017-08-01

    It is unknown if central venous catheters bypass the skin's electrical resistance and engender a risk of nerve conduction study-induced cardiac arrhythmia. The objective of this study is to determine if nerve conduction studies affect cardiac conduction and rhythm in patients with central venous catheters. Under continuous 12-lead electrocardiogram monitoring, subjects with and without central venous catheters underwent a series of upper extremity nerve conduction studies. A cardiologist reviewed the electrocardiogram tracings for evidence of cardiac conduction abnormality or arrhythmia. Ten control subjects and 10 subjects with central venous catheters underwent the nerve conduction study protocol. No malignant arrhythmias or conduction abnormalities were noted in either group. Nerve conduction studies of the upper extremities, including both proximal stimulation and repetitive stimulation, do not appear to confer increased risk of cardiac conduction abnormality in those patients with central venous catheters who are not critically ill or have a prior history of arrhythmia. Muscle Nerve 56: 321-323, 2017. © 2016 Wiley Periodicals, Inc.

  12. [Clinical aspects of reperfusion arrhythmia following intravenous thrombolysis in acute myocardial infarct].

    PubMed

    Kettner, W; Klein, E; Schulz, W; Götze, C

    1987-05-15

    In accordance with the majority of the reports in the literature reperfusion arrhythmias were observed in more than 30% of the patients with acute myocardial infarction (n = 25) under or immediately after a highly dosed short-term infusion with streptokinase. With reference to indirect signs the recanalisation rate was assumed with 75%. Only one third of the reperfusion arrhythmias had haemodynamically significant characteristics and required an influence. Though in literature from animal experimental findings directive conclusions for the therapy are to be derived, the procedure in practice is still vastly empirical. In the ventricular tachycardia lidocaine, procainamide and ajmalin may be recommended. In ineffectiveness or particularly threatening situations the electrotherapy (cardioversion, DC-shock) is to be preferred. The concept inaugurated by Corr and Witkowski apply alpha-adrenoreceptor blockers has not yet entered the clinical practice. Possible problems in the treatment of reperfusion arrhythmias in the prehospital phase should at present still be a reason not to antedate the thrombolytic therapy into this phase.

  13. Right Ventricular Myocardial Ischemia with Arrhythmia in an Asphyxiated Newborn

    PubMed Central

    Solevåg, Anne Lee; Schmölzer, Georg M.; Cheung, Po-Yin

    2016-01-01

    Background Infant and neonatal myocardial infarction (MI) has been described in association with congenital heart disease, coronary artery abnormalities, myocarditis, and tumors. MI in the perinatal period in a structurally normal heart and with ventricular arrhythmia as a presenting feature has not been thoroughly described. Published case reports describe treatment methods extrapolated from adult MI. However, due to the rare occurrence, the most appropriate acute treatment for both MI and ventricular arrhythmia in newborn infants remains unknown. Case A male term infant with perinatal asphyxia and need for extensive cardiopulmonary resuscitation at birth had ventricular tachyarrhythmia and ST-elevations on electrocardiogram. Four hours after birth, he died from cardiogenic failure. A thrombus at the right coronary artery was found on autopsy. Conclusion MI in the perinatal period in a structurally normal heart is very rare and mortality is high. Although acute treatments extrapolated from adult MI has been described to result in favorable outcomes in newborn infants, guidelines are lacking on how to manage acute MI and associated ventricular arrhythmia. PMID:27280062

  14. Systems approach to the study of stretch and arrhythmias in right ventricular failure induced in rats by monocrotaline

    PubMed Central

    Benoist, David; Stones, Rachel; Benson, Alan P.; Fowler, Ewan D.; Drinkhill, Mark J.; Hardy, Matthew E.L.; Saint, David A.; Cazorla, Olivier; Bernus, Olivier; White, Ed

    2014-01-01

    We demonstrate the synergistic benefits of using multiple technologies to investigate complex multi-scale biological responses. The combination of reductionist and integrative methodologies can reveal novel insights into mechanisms of action by tracking changes of in vivo phenomena to alterations in protein activity (or vice versa). We have applied this approach to electrical and mechanical remodelling in right ventricular failure caused by monocrotaline-induced pulmonary artery hypertension in rats. We show arrhythmogenic T-wave alternans in the ECG of conscious heart failure animals. Optical mapping of isolated hearts revealed discordant action potential duration (APD) alternans. Potential causes of the arrhythmic substrate; structural remodelling and/or steep APD restitution and dispersion were observed, with specific remodelling of the Right Ventricular Outflow Tract. At the myocyte level, [Ca2+]i transient alternans were observed together with decreased activity, gene and protein expression of the sarcoplasmic reticulum Ca2+-ATPase (SERCA). Computer simulations of the electrical and structural remodelling suggest both contribute to a less stable substrate. Echocardiography was used to estimate increased wall stress in failure, in vivo. Stretch of intact and skinned single myocytes revealed no effect on the Frank-Starling mechanism in failing myocytes. In isolated hearts acute stretch-induced arrhythmias occurred in all preparations. Significant shortening of the early APD was seen in control but not failing hearts. These observations may be linked to changes in the gene expression of candidate mechanosensitive ion channels (MSCs) TREK-1 and TRPC1/6. Computer simulations incorporating MSCs and changes in ion channels with failure, based on altered gene expression, largely reproduced experimental observations. PMID:25016242

  15. Identification of cardiac rhythm features by mathematical analysis of vector fields.

    PubMed

    Fitzgerald, Tamara N; Brooks, Dana H; Triedman, John K

    2005-01-01

    Automated techniques for locating cardiac arrhythmia features are limited, and cardiologists generally rely on isochronal maps to infer patterns in the cardiac activation sequence during an ablation procedure. Velocity vector mapping has been proposed as an alternative method to study cardiac activation in both clinical and research environments. In addition to the visual cues that vector maps can provide, vector fields can be analyzed using mathematical operators such as the divergence and curl. In the current study, conduction features were extracted from velocity vector fields computed from cardiac mapping data. The divergence was used to locate ectopic foci and wavefront collisions, and the curl to identify central obstacles in reentrant circuits. Both operators were applied to simulated rhythms created from a two-dimensional cellular automaton model, to measured data from an in situ experimental canine model, and to complex three-dimensional human cardiac mapping data sets. Analysis of simulated vector fields indicated that the divergence is useful in identifying ectopic foci, with a relatively small number of vectors and with errors of up to 30 degrees in the angle measurements. The curl was useful for identifying central obstacles in reentrant circuits, and the number of velocity vectors needed increased as the rhythm became more complex. The divergence was able to accurately identify canine in situ pacing sites, areas of breakthrough activation, and wavefront collisions. In data from human arrhythmias, the divergence reliably estimated origins of electrical activity and wavefront collisions, but the curl was less reliable at locating central obstacles in reentrant circuits, possibly due to the retrospective nature of data collection. The results indicate that the curl and divergence operators applied to velocity vector maps have the potential to add valuable information in cardiac mapping and can be used to supplement human pattern recognition.

  16. Exploiting periodicity to extract the atrial activity in atrial arrhythmias

    NASA Astrophysics Data System (ADS)

    Llinares, Raul; Igual, Jorge

    2011-12-01

    Atrial fibrillation disorders are one of the main arrhythmias of the elderly. The atrial and ventricular activities are decoupled during an atrial fibrillation episode, and very rapid and irregular waves replace the usual atrial P-wave in a normal sinus rhythm electrocardiogram (ECG). The estimation of these wavelets is a must for clinical analysis. We propose a new approach to this problem focused on the quasiperiodicity of these wavelets. Atrial activity is characterized by a main atrial rhythm in the interval 3-12 Hz. It enables us to establish the problem as the separation of the original sources from the instantaneous linear combination of them recorded in the ECG or the extraction of only the atrial component exploiting the quasiperiodic feature of the atrial signal. This methodology implies the previous estimation of such main atrial period. We present two algorithms that separate and extract the atrial rhythm starting from a prior estimation of the main atrial frequency. The first one is an algebraic method based on the maximization of a cost function that measures the periodicity. The other one is an adaptive algorithm that exploits the decorrelation of the atrial and other signals diagonalizing the correlation matrices at multiple lags of the period of atrial activity. The algorithms are applied successfully to synthetic and real data. In simulated ECGs, the average correlation index obtained was 0.811 and 0.847, respectively. In real ECGs, the accuracy of the results was validated using spectral and temporal parameters. The average peak frequency and spectral concentration obtained were 5.550 and 5.554 Hz and 56.3 and 54.4%, respectively, and the kurtosis was 0.266 and 0.695. For validation purposes, we compared the proposed algorithms with established methods, obtaining better results for simulated and real registers.

  17. Quantifying the effect of complications on patient flow, costs and surgical throughputs.

    PubMed

    Almashrafi, Ahmed; Vanderbloemen, Laura

    2016-10-21

    Postoperative adverse events are known to increase length of stay and cost. However, research on how adverse events affect patient flow and operational performance has been relatively limited to date. Moreover, there is paucity of studies on the use of simulation in understanding the effect of complications on care processes and resources. In hospitals with scarcity of resources, postoperative complications can exert a substantial influence on hospital throughputs. This paper describes an evaluation method for assessing the effect of complications on patient flow within a cardiac surgical department. The method is illustrated by a case study where actual patient-level data are incorporated into a discrete event simulation (DES) model. The DES model uses patient data obtained from a large hospital in Oman to quantify the effect of complications on patient flow, costs and surgical throughputs. We evaluated the incremental increase in resources due to treatment of complications using Poisson regression. Several types of complications were examined such as cardiac complications, pulmonary complications, infection complications and neurological complications. 48 % of the patients in our dataset experienced one or more complications. The most common types of complications were ventricular arrhythmia (16 %) followed by new atrial arrhythmia (15.5 %) and prolonged ventilation longer than 24 h (12.5 %). The total number of additional days associated with infections was the highest, while cardiac complications have resulted in the lowest number of incremental days of hospital stay. Complications had a significant effect on perioperative operational performance such as surgery cancellations and waiting time. The effect was profound when complications occurred in the Cardiac Intensive Care (CICU) where a limited capacity was observed. The study provides evidence supporting the need to incorporate adverse events data in resource planning to improve hospital performance.

  18. Is exposure to ionising radiation associated with childhood cardiac arrhythmia in the Russian territories contaminated by the Chernobyl fallout? A cross-sectional population-based study

    PubMed Central

    Clero, Enora; Doroshchenko, Vladimir; Silenok, Aleksandr; Kurnosova, Irina; Butsenin, Andrei; Denjoy, Isabelle; Franck, Didier; Heuze, Jean-Pierre; Gourmelon, Patrick

    2018-01-01

    Objective To investigate childhood cardiac arrhythmia and chronic exposure to caesium-137 (137Cs) resulting from the Chernobyl accident. Design Prospective cross-sectional study using exposed/unexposed design conducted in the Bryansk region from May 2009 to May 2013 on children selected on the basis of 137Cs soil deposition: control territories ([137Cs]<37 kBq per square metre, where children were considered as unexposed) and contaminated territories ([137Cs]>555 kBq per square metre, where children were considered as exposed). Setting Russian territories affected by the Chernobyl fallout (Bryansk region). Participants This cross-sectional study included 18 152 children aged 2–18 years and living in the Bryansk region (Russia). Main outcome measures All children received three medical examinations (ECG, echocardiography and 137Cs whole-body activity measurement) and some of them were given with a 24-hour Holter monitoring and blood tests. Results Cardiac arrhythmia was diagnosed in 1172 children living in contaminated territories and 1354 children living in control territories. The crude prevalence estimated to 13.3% in contaminated territories was significantly lower than in control territories with 15.2% over the period 2009–2013 (P<0.001). Considering 137Cs whole-body burden as exposure, cardiac arrhythmia was found in 449 contaminated children and 2077 uncontaminated children, corresponding to an estimated crude prevalence of 14.5% and 14.2%, respectively, which does not differ significantly (P=0.74). Also, we investigated the association between territory, exposure to 137Cs and cardiac arrhythmia: the adjusted OR was not significant (0.90 with 95% CI 0.81 to 1.00; P=0.06) for the territory. For 137Cs whole-body burden, the ORs close to 1 did not reach statistical significance (P for trend=0.97). Conclusion This study does not observe an association between cardiac arrhythmia and 137Cs deposition levels in the Bryansk region exposed to Chernobyl fallout. The suspected increase of cardiac arrhythmia in children exposed to Chernobyl fallout is not confirmed. PMID:29581199

  19. Emerging therapeutic targets in the short QT syndrome.

    PubMed

    Hancox, Jules C; Whittaker, Dominic G; Du, Chunyun; Stuart, A Graham; Zhang, Henggui

    2018-05-01

    Short QT Syndrome (SQTS) is a rare but dangerous condition characterised by abbreviated repolarisation, atrial and ventricular arrhythmias and risk of sudden death. Implantable cardioverter defibrillators (ICDs) are a first line protection against sudden death, but adjunct pharmacology is beneficial and desirable. Areas covered: The genetic basis for genotyped SQTS variants (SQT1-SQT8) and evidence for arrhythmia substrates from experimental and simulation studies are discussed. The main ion channel/transporter targets for antiarrhythmic pharmacology are considered in respect of potential genotype-specific and non-specific treatments for the syndrome. Expert opinion: Potassium channel blockade is valuable for restoring repolarisation and QT interval, though genotype-specific limitations exist in the use of some K + channel inhibitors. A combination of K + current inhibition during the action potential plateau, with sodium channel inhibition that collectively result in delaying repolarisation and post-repolarisation refractoriness is likely to be valuable in prolonging effective refractory period and wavelength for re-entry. Genotype-specific K + channel inhibition is limited by a lack of targeted inhibitors in clinical use, though experimentally available selective inhibitors now exist. The relatively low proportion of successfully genotyped cases justifies an exome or genome sequencing approach, to reveal new mediators and targets, as demonstrated recently for SLC4A3 in SQT8.

  20. Upregulation of adenosine A1 receptors facilitates sinoatrial node dysfunction in chronic canine heart failure by exacerbating nodal conduction abnormalities revealed by novel dual-sided intramural optical mapping.

    PubMed

    Lou, Qing; Hansen, Brian J; Fedorenko, Olga; Csepe, Thomas A; Kalyanasundaram, Anuradha; Li, Ning; Hage, Lori T; Glukhov, Alexey V; Billman, George E; Weiss, Raul; Mohler, Peter J; Györke, Sándor; Biesiadecki, Brandon J; Carnes, Cynthia A; Fedorov, Vadim V

    2014-07-22

    Although sinoatrial node (SAN) dysfunction is a hallmark of human heart failure (HF), the underlying mechanisms remain poorly understood. We aimed to examine the role of adenosine in SAN dysfunction and tachy-brady arrhythmias in chronic HF. We applied multiple approaches to characterize SAN structure, SAN function, and adenosine A1 receptor expression in control (n=17) and 4-month tachypacing-induced chronic HF (n=18) dogs. Novel intramural optical mapping of coronary-perfused right atrial preparations revealed that adenosine (10 μmol/L) markedly prolonged postpacing SAN conduction time in HF by 206 ± 99 milliseconds (versus 66 ± 21 milliseconds in controls; P=0.02). Adenosine induced SAN intranodal conduction block or microreentry in 6 of 8 dogs with HF versus 0 of 7 controls (P=0.007). Adenosine-induced SAN conduction abnormalities and automaticity depression caused postpacing atrial pauses in HF versus control dogs (17.1 ± 28.9 versus 1.5 ± 1.3 seconds; P<0.001). Furthermore, 10 μmol/L adenosine shortened atrial repolarization and led to pacing-induced atrial fibrillation in 6 of 7 HF versus 0 of 7 control dogs (P=0.002). Adenosine-induced SAN dysfunction and atrial fibrillation were abolished or prevented by adenosine A1 receptor antagonists (50 μmol/L theophylline/1 μmol/L 8-cyclopentyl-1,3-dipropylxanthine). Adenosine A1 receptor protein expression was significantly upregulated during HF in the SAN (by 47 ± 19%) and surrounding atrial myocardium (by 90 ± 40%). Interstitial fibrosis was significantly increased within the SAN in HF versus control dogs (38 ± 4% versus 23 ± 4%; P<0.001). In chronic HF, adenosine A1 receptor upregulation in SAN pacemaker and atrial cardiomyocytes may increase cardiac sensitivity to adenosine. This effect may exacerbate conduction abnormalities in the structurally impaired SAN, leading to SAN dysfunction, and potentiate atrial repolarization shortening, thereby facilitating atrial fibrillation. Atrial fibrillation may further depress SAN function and lead to tachy-brady arrhythmias in HF. © 2014 American Heart Association, Inc.

  1. GPU based cloud system for high-performance arrhythmia detection with parallel k-NN algorithm.

    PubMed

    Tae Joon Jun; Hyun Ji Park; Hyuk Yoo; Young-Hak Kim; Daeyoung Kim

    2016-08-01

    In this paper, we propose an GPU based Cloud system for high-performance arrhythmia detection. Pan-Tompkins algorithm is used for QRS detection and we optimized beat classification algorithm with K-Nearest Neighbor (K-NN). To support high performance beat classification on the system, we parallelized beat classification algorithm with CUDA to execute the algorithm on virtualized GPU devices on the Cloud system. MIT-BIH Arrhythmia database is used for validation of the algorithm. The system achieved about 93.5% of detection rate which is comparable to previous researches while our algorithm shows 2.5 times faster execution time compared to CPU only detection algorithm.

  2. Sleep-Disordered Breathing and Arrhythmia in Heart Failure Patients.

    PubMed

    Fox, Henrik; Bitter, Thomas; Horstkotte, Dieter; Oldenburg, Olaf

    2017-06-01

    Heart failure (HF) treatment remains complex and challenging, with current recommendations aiming at consideration and treatment of comorbidities in patients with HF. Sleep-disordered breathing (SDB) and arrhythmia come into play, as both are associated with quality of life deterioration, and morbidity and mortality increase in patients with HF. Interactions of these diseases are versatile and may appear intransparent in daily practice. Nevertheless, because of their importance for patients' condition and prognosis, SDB and arrhythmia individually, but also through interaction on one another, necessitate attention, following the fact that treatment is requested and desired considering latest research findings and outcomes. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Analysis of electrolyte abnormalities and the mechanisms leading to arrhythmias in heart failure. A literature review.

    PubMed

    Urso, C; Canino, B; Brucculeri, S; Firenze, A; Caimi, G

    2016-01-01

    About 50% of deaths from heart failure (HF) are sudden, presumably referable to arrhythmias. Electrolyte and acid-base abnormalities are a frequent and potentially dangerous complication in HF patients. Their incidence is almost always correlated with the severity of cardiac dysfunction; furthermore leading to arrhythmias, these imbalances are associated with a poor prognosis. The frequency of ventricular ectopic beats and sudden cardiac death correlate with both plasma and whole body levels of potassium, especially in alkalemia. The early recognition of these alterations and the knowledge of the pathophysiological mechanisms are useful for the management of these HF patients.

  4. Do defects in ion channel glycosylation set the stage for lethal cardiac arrhythmias?

    PubMed

    Fozzard, Harry A; Kyle, John W

    2002-04-30

    Many ion channels are modified by the addition of carbohydrate residues. Fozzard and Kyle discuss evidence that sialic acid residues on glycosylated cardiac sodium and potassium channels may be important for preventing early after-depolarizations that can result in cardiac arrhythmias.

  5. Particles Alter Diesel Exhaust Gases-Induced Hypotension, Cardiac Arrhythmia,Conduction Disturbance, and Autonomic Imbalance in Heart Failure-Prone Rats

    EPA Science Inventory

    Epidemiologic studies indicate that acute exposures to vehicular traffic and particulate matter (PM) air pollution are key causes of fatal cardiac arrhythmia, especially in those with preexisting cardiovascular disease. Researchers point to electrophysiologic dysfunction and auto...

  6. A single exposure to acrolein causes arrhythmogenesis, cardiac electrical dysfunction and decreased heart rate variability in hypertensive rats

    EPA Science Inventory

    Epidemiological studies demonstrate an association between cardiovascular morbidity, arrhythmias, and exposure to air toxicants such as acrolein. We hypothesized that a single exposure to acrolein would increase arrhythmias and cause changes in the electrocardiogram (ECG) of hype...

  7. A simulation of T-wave alternans vectocardiographic representation performed by changing the ventricular heart cells action potential duration.

    PubMed

    Janusek, D; Kania, M; Zaczek, R; Zavala-Fernandez, H; Maniewski, R

    2014-04-01

    The presence of T wave alternans (TWA) in the surface ECG signals has been recognized as a marker of electrical instability, and is hypothesized to be related to patients at increased risk for ventricular arrhythmias. In this paper we present a TWA simulation study. The TWA phenomenon was simulated by changing the duration of the ventricular heart cells action potential. The magnitude was calculated in the surface ECG with the use of the time domain method. The spatially concordant TWA, where during one heart beat all ventricular cells display a short-duration action potential and during the next beat they exhibit a long-duration action potential, as well as the discordant TWA, where at least one region is out of phase, was simulated. The vectocardiographic representation was employed. The obtained results showed a high level of T-loop pattern and location disturbances connected to the discordant TWA simulation in contrast to the concordant one. This result may be explained by the spatial heterogeneity of the ventricular repolarization process, which could be higher for the discordant TWA than for the concordant TWA. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  8. Accelerating sino-atrium computer simulations with graphic processing units.

    PubMed

    Zhang, Hong; Xiao, Zheng; Lin, Shien-fong

    2015-01-01

    Sino-atrial node cells (SANCs) play a significant role in rhythmic firing. To investigate their role in arrhythmia and interactions with the atrium, computer simulations based on cellular dynamic mathematical models are generally used. However, the large-scale computation usually makes research difficult, given the limited computational power of Central Processing Units (CPUs). In this paper, an accelerating approach with Graphic Processing Units (GPUs) is proposed in a simulation consisting of the SAN tissue and the adjoining atrium. By using the operator splitting method, the computational task was made parallel. Three parallelization strategies were then put forward. The strategy with the shortest running time was further optimized by considering block size, data transfer and partition. The results showed that for a simulation with 500 SANCs and 30 atrial cells, the execution time taken by the non-optimized program decreased 62% with respect to a serial program running on CPU. The execution time decreased by 80% after the program was optimized. The larger the tissue was, the more significant the acceleration became. The results demonstrated the effectiveness of the proposed GPU-accelerating methods and their promising applications in more complicated biological simulations.

  9. [Risk of arrhythmia and domestic low-voltage electrical injury].

    PubMed

    Claudet, I; Maréchal, C; Debuisson, C; Salanne, S

    2010-04-01

    Analysis of domestic low-voltage (220-240 V) electrical injury in children admitted to a pediatric emergency department to illustrate the low risk of initial or delayed risk of arrhythmia. Retrospective study between 2001 and 2008 analyzing all children aged less than 15 years admitted for a low-voltage electrical injury. The data collected were age, sex, time and circumstances of the accident, time and day of admission, transport modalities, presence of risk factors for arrhythmia (transthoracic current, wet skin, tetany, loss of consciousness or neurological symptoms, and initial EKG abnormalities), injuries, EKG, muscular and/or cardiac enzyme values, progression and complications. For statistical analysis, data were entered in Microsoft Excel tables. Analysis was done with StatView5.1 (SAS Institute) and Epi Info 6.04fr (VF, ENSP epiconcept). In the descriptive analysis, the data are presented as mean values with SD, median and range. Forty-eight children were included. The mean annual number of admissions was equal to 6 (range, 3-12). The mean age was 6.2 + or - 4.3 years (median, 4.6 years). There was a male predominance: the overall sex ratio was 1.5, i.e., 3 before the age of 2 and 2.6 before the age of 10. The electrical injury occurred after contact with a wire or a connected cord or after the introduction of a metallic object in a wall socket. Ten children had risk factors of arrhythmia (mainly wet skin or thoracic pain). Twenty-nine children suffered from burns to the extremities (digits and hands, 70 %). At admission, 45 children had an EKG performed. The initial EKG was considered abnormal in 8 cases showing: sinusal tachycardia (n=4), incomplete right bundle branch block (n=4), and V(1) negative T waves (n=1). The EKG normalized within the first 12h. Hospitalization for cardiac monitoring was required for 18 children. No delayed arrhythmia occurred. In a mean time of 3.5h after the accident, a troponin dosage was given to 15 children and was normal in all cases. One child developed rhabdomyolysis and evolved without needing dialysis. After a low-voltage electrical injury, initial arrhythmia is not frequent, with often a nonspecific and transitory EKG expression; delayed arrhythmia is very rare. Children presenting to the emergency department after such an electrical accident, who are asymptomatic, without any risk factors for arrhythmia (wet skin, tetany, vertical pathway of the current, preexistent cardiological conditions, loss of consciousness) and with a normal initial EKG do not require cardiac monitoring. Copyright 2010 Elsevier Masson SAS. All rights reserved.

  10. Method matters: impact of in-scenario instruction on simulation-based teamwork training.

    PubMed

    Escher, Cecilia; Rystedt, Hans; Creutzfeldt, Johan; Meurling, Lisbet; Nyström, Sofia; Dahlberg, Johanna; Edelbring, Samuel; Nordahl Amorøe, Torben; Hult, Håkan; Felländer-Tsai, Li; Abrandt-Dahlgren, Madeleine

    2017-01-01

    The rationale for introducing full-scale patient simulators in training to improve patient safety is to recreate clinical situations in a realistic setting. Although high-fidelity simulators mimic a wide range of human features, simulators differ from the body of a sick patient. The gap between the simulator and the human body implies a need for facilitators to provide information to help participants understand scenarios. The authors aimed at describing different methods that facilitators in our dataset used to provide such extra scenario information and how the different methods to convey information affected how scenarios played out. A descriptive qualitative study was conducted to examine the variation of methods to deliver extra scenario information to participants. A multistage approach was employed. The authors selected film clips from a shared database of 31 scenarios from three participating simulation centers. A multidisciplinary research team performed a collaborative analysis of representative film clips focusing on the interplay between participants, facilitators, and the physical environment. After that, the entire material was revisited to further examine and elaborate the initial findings. The material displayed four distinct methods for facilitators to convey information to participants in simulation-based teamwork training. The choice of method had impact on the participating teams regarding flow of work, pace, and team communication. Facilitators' close access to the teams' activities when present in the simulation suite, either embodied or disembodied in the simulation, facilitated the timing for providing information, which was critical for maintaining the flow of activities in the scenario. The mediation of information by a loudspeaker or an earpiece from the adjacent operator room could be disturbing for team communication. In-scenario instruction is an essential component of simulation-based teamwork training that has been largely overlooked in previous research. The ways in which facilitators convey information about the simulated patient have the potential to shape the simulation activities and thereby serve different learning goals. Although immediate timing to maintain an adequate pace is necessary for professionals to engage in training of medical emergencies, novices may gain from a slower tempo to train complex clinical team tasks systematically.

  11. Use of whole exome sequencing for the identification of Ito-based arrhythmia mechanism and therapy.

    PubMed

    Sturm, Amy C; Kline, Crystal F; Glynn, Patric; Johnson, Benjamin L; Curran, Jerry; Kilic, Ahmet; Higgins, Robert S D; Binkley, Philip F; Janssen, Paul M L; Weiss, Raul; Raman, Subha V; Fowler, Steven J; Priori, Silvia G; Hund, Thomas J; Carnes, Cynthia A; Mohler, Peter J

    2015-05-26

    Identified genetic variants are insufficient to explain all cases of inherited arrhythmia. We tested whether the integration of whole exome sequencing with well-established clinical, translational, and basic science platforms could provide rapid and novel insight into human arrhythmia pathophysiology and disease treatment. We report a proband with recurrent ventricular fibrillation, resistant to standard therapeutic interventions. Using whole-exome sequencing, we identified a variant in a previously unidentified exon of the dipeptidyl aminopeptidase-like protein-6 (DPP6) gene. This variant is the first identified coding mutation in DPP6 and augments cardiac repolarizing current (Ito) causing pathological changes in Ito and action potential morphology. We designed a therapeutic regimen incorporating dalfampridine to target Ito. Dalfampridine, approved for multiple sclerosis, normalized the ECG and reduced arrhythmia burden in the proband by >90-fold. This was combined with cilostazol to accelerate the heart rate to minimize the reverse-rate dependence of augmented Ito. We describe a novel arrhythmia mechanism and therapeutic approach to ameliorate the disease. Specifically, we identify the first coding variant of DPP6 in human ventricular fibrillation. These findings illustrate the power of genetic approaches for the elucidation and treatment of disease when carefully integrated with clinical and basic/translational research teams. © 2015 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  12. Surgical outcome of Fontan conversion and arrhythmia surgery: Need a pacemaker?

    PubMed

    Terada, Takafumi; Sakurai, Hajime; Nonaka, Toshimichi; Sakurai, Takahisa; Sugiura, Junya; Taneichi, Tetsuyoshi; Ohtsuka, Ryohei

    2014-07-01

    Atrial tachyarrhythmias are frequent complications in the late period after the Fontan procedure, and important risk factors for a poor prognosis. The impact of Fontan conversion and arrhythmia surgery in failed Fontan patients has been described in many reports. We evaluated our experience with Fontan conversion procedures, concomitant arrhythmia surgery, and pacemaker implantation. We reviewed the hospital records of 25 consecutive patients who underwent a Fontan conversion procedure from January 2004 to March 2012. Twenty-four patients had arrhythmia surgery using cryoablation and radiofrequency ablation at the time of conversion. A bilateral atrial maze procedure was performed in 6 patients, right-side maze in 15, and isthmus block in 3. Three patients with a diagnosis of corrected transposition of the great arteries underwent simultaneous pacemaker implantation electively. There was no early death and one late death during a mean follow-up period of 21.2 months. Three tachyarrhythmia recurrences developed, and there were 4 occurrences of sinus bradycardia. Five of these patients required postoperative pacemaker implantation. The mid-term results of Fontan conversion and arrhythmia surgery in our institute were satisfactory. The occurrence of unexpected postoperative pacemaker requirement was high in the patients who underwent a right atrial or bilateral atrial maze procedure. Pacemaker or lead implantation is recommended for patients planned to undergo a right-side or full maze procedure. © The Author(s) 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  13. Design of a hybrid model for cardiac arrhythmia classification based on Daubechies wavelet transform.

    PubMed

    Rajagopal, Rekha; Ranganathan, Vidhyapriya

    2018-06-05

    Automation in cardiac arrhythmia classification helps medical professionals make accurate decisions about the patient's health. The aim of this work was to design a hybrid classification model to classify cardiac arrhythmias. The design phase of the classification model comprises the following stages: preprocessing of the cardiac signal by eliminating detail coefficients that contain noise, feature extraction through Daubechies wavelet transform, and arrhythmia classification using a collaborative decision from the K nearest neighbor classifier (KNN) and a support vector machine (SVM). The proposed model is able to classify 5 arrhythmia classes as per the ANSI/AAMI EC57: 1998 classification standard. Level 1 of the proposed model involves classification using the KNN and the classifier is trained with examples from all classes. Level 2 involves classification using an SVM and is trained specifically to classify overlapped classes. The final classification of a test heartbeat pertaining to a particular class is done using the proposed KNN/SVM hybrid model. The experimental results demonstrated that the average sensitivity of the proposed model was 92.56%, the average specificity 99.35%, the average positive predictive value 98.13%, the average F-score 94.5%, and the average accuracy 99.78%. The results obtained using the proposed model were compared with the results of discriminant, tree, and KNN classifiers. The proposed model is able to achieve a high classification accuracy.

  14. Real time reconstruction of quasiperiodic multi parameter physiological signals

    NASA Astrophysics Data System (ADS)

    Ganeshapillai, Gartheeban; Guttag, John

    2012-12-01

    A modern intensive care unit (ICU) has automated analysis systems that depend on continuous uninterrupted real time monitoring of physiological signals such as electrocardiogram (ECG), arterial blood pressure (ABP), and photo-plethysmogram (PPG). These signals are often corrupted by noise, artifacts, and missing data. We present an automated learning framework for real time reconstruction of corrupted multi-parameter nonstationary quasiperiodic physiological signals. The key idea is to learn a patient-specific model of the relationships between signals, and then reconstruct corrupted segments using the information available in correlated signals. We evaluated our method on MIT-BIH arrhythmia data, a two-channel ECG dataset with many clinically significant arrhythmias, and on the CinC challenge 2010 data, a multi-parameter dataset containing ECG, ABP, and PPG. For each, we evaluated both the residual distance between the original signals and the reconstructed signals, and the performance of a heartbeat classifier on a reconstructed ECG signal. At an SNR of 0 dB, the average residual distance on the CinC data was roughly 3% of the energy in the signal, and on the arrhythmia database it was roughly 16%. The difference is attributable to the large amount of diversity in the arrhythmia database. Remarkably, despite the relatively high residual difference, the classification accuracy on the arrhythmia database was still 98%, indicating that our method restored the physiologically important aspects of the signal.

  15. ECG signal quality during arrhythmia and its application to false alarm reduction.

    PubMed

    Behar, Joachim; Oster, Julien; Li, Qiao; Clifford, Gari D

    2013-06-01

    An automated algorithm to assess electrocardiogram (ECG) quality for both normal and abnormal rhythms is presented for false arrhythmia alarm suppression of intensive care unit (ICU) monitors. A particular focus is given to the quality assessment of a wide variety of arrhythmias. Data from three databases were used: the Physionet Challenge 2011 dataset, the MIT-BIH arrhythmia database, and the MIMIC II database. The quality of more than 33 000 single-lead 10 s ECG segments were manually assessed and another 12 000 bad-quality single-lead ECG segments were generated using the Physionet noise stress test database. Signal quality indices (SQIs) were derived from the ECGs segments and used as the inputs to a support vector machine classifier with a Gaussian kernel. This classifier was trained to estimate the quality of an ECG segment. Classification accuracies of up to 99% on the training and test set were obtained for normal sinus rhythm and up to 95% for arrhythmias, although performance varied greatly depending on the type of rhythm. Additionally, the association between 4050 ICU alarms from the MIMIC II database and the signal quality, as evaluated by the classifier, was studied. Results suggest that the SQIs should be rhythm specific and that the classifier should be trained for each rhythm call independently. This would require a substantially increased set of labeled data in order to train an accurate algorithm.

  16. More Than One Way to Debrief: A Critical Review of Healthcare Simulation Debriefing Methods.

    PubMed

    Sawyer, Taylor; Eppich, Walter; Brett-Fleegler, Marisa; Grant, Vincent; Cheng, Adam

    2016-06-01

    Debriefing is a critical component in the process of learning through healthcare simulation. This critical review examines the timing, facilitation, conversational structures, and process elements used in healthcare simulation debriefing. Debriefing occurs either after (postevent) or during (within-event) the simulation. The debriefing conversation can be guided by either a facilitator (facilitator-guided) or the simulation participants themselves (self-guided). Postevent facilitator-guided debriefing may incorporate several conversational structures. These conversational structures break the debriefing discussion into a series of 3 or more phases to help organize the debriefing and ensure the conversation proceeds in an orderly manner. Debriefing process elements are an array of techniques to optimize reflective experience and maximize the impact of debriefing. These are divided here into the following 3 categories: essential elements, conversational techniques/educational strategies, and debriefing adjuncts. This review provides both novice and advanced simulation educators with an overview of various methods of conducting healthcare simulation debriefing. Future research will investigate which debriefing methods are best for which contexts and for whom, and also explore how lessons from simulation debriefing translate to debriefing in clinical practice.

  17. Congenital Deafness with Cardiac Arrhythmias: The Jervell and Lange-Nielsen Syndrome.

    ERIC Educational Resources Information Center

    Wahl, Richard A.; Macdonald, Dick, II

    1980-01-01

    The Jervell and Lange-Nielsen syndrome, affecting 0.3 percent of congenitally deaf persons, consists of severe cardiac arrhythmias and sensorineural hearing loss. The authors recommend that every congenitally deaf child with suspicious symptoms receive an electrocardiogram and that professionals who work with deaf children not only inform…

  18. A single exposure to particulate or gaseous air pollution increases the risk of aconitine-induced cardiac arrythmia in hypertensive rats

    EPA Science Inventory

    Epidemiological studies demonstrate a significant association between arrhythmias and air pollution exposure. Sensitivity to aconitine-induced arrhythmia has been used repeatedly to examine the factors that increase the risk of such cardiac electrical dysfunction. In this study, ...

  19. Brief Report: Social Skills, Internalizing and Externalizing Symptoms, and Respiratory Sinus Arrhythmia in Autism

    ERIC Educational Resources Information Center

    Neuhaus, Emily; Bernier, Raphael; Beauchaine, Theodore P.

    2014-01-01

    Theoretical and empirical models describe respiratory sinus arrhythmia (RSA) as a peripheral biomarker of emotion regulation and social competence. Recent findings also link RSA to individual differences in social functioning within autism spectrum disorder (ASD). However, associations between RSA and symptoms of internalizing/externalizing…

  20. High-intensity, occupation-specific training in a series of firefighters during phase II cardiac rehabilitation.

    PubMed

    Adams, Jenny; Cheng, Dunlei; Berbarie, Rafic F

    2013-04-01

    Six male firefighters who were referred to phase II cardiac rehabilitation after coronary revascularization participated in a specialized regimen of high-intensity, occupation-specific training (HIOST) that simulated firefighting tasks. During each session, the electrocardiogram, heart rate, and blood pressure were monitored, and the patients were observed for adverse symptoms. No patient had to discontinue HIOST because of adverse arrhythmias or symptoms. For physicians who must make decisions about return to work, the information collected over multiple HIOST sessions might be more thorough and conclusive than the information gained during a single treadmill exercise stress test (the recommended evaluation method).

  1. Vectorcardiographic changes during extended space flight (M093): Observations at rest and during exercise

    NASA Technical Reports Server (NTRS)

    Smith, R. F.; Stanton, K.; Stoop, D.; Brown, D.; Janusz, W.; King, P.

    1977-01-01

    The objectives of Skylab Experiment M093 were to measure electrocardiographic signals during space flight, to elucidate the electrophysiological basis for the changes observed, and to assess the effect of the change on the human cardiovascular system. Vectorcardiographic methods were used to quantitate changes, standardize data collection, and to facilitate reduction and statistical analysis of data. Since the Skylab missions provided a unique opportunity to study the effects of prolonged weightlessness on human subjects, an effort was made to construct a data base that contained measurements taken with precision and in adequate number to enable conclusions to be made with a high degree of confidence. Standardized exercise loads were incorporated into the experiment protocol to increase the sensitivity of the electrocardiogram for effects of deconditioning and to detect susceptability for arrhythmias.

  2. Biomarkers in electrophysiology: role in arrhythmias and resynchronization therapy

    PubMed Central

    Bose, Abhishek; Truong, Quynh A.

    2015-01-01

    Circulating biomarkers related to inflammation, neurohormones, myocardial stress, and necrosis have been associated with commonly encountered arrhythmic disorders such as atrial fibrillation (AF) and more malignant processes including ventricular arrhythmias (VA) and sudden cardiac death (SCD). Both direct and indirect biomarkers implicated in the heart failure cascade have potential prognostic value in patients undergoing cardiac resynchronization therapy (CRT). This review will focus on the role of biomarkers in AF, history of SCD, and CRT with an emphasis to improve clinical risk assessment for arrhythmias and patient selection for device therapy. Notably, information obtained from biomarkers may supplement traditional diagnostic and imaging techniques, thus providing an additional benefit in the management of patients. PMID:25715916

  3. Unique Association of Rare Cardiovascular Disease in an Athlete With Ventricular Arrhythmias.

    PubMed

    Santomauro, V; Contursi, M; Dellegrottaglie, S; Borsellino, G

    2015-01-01

    Ventricular arrhythmias are a leading cause of non-elegibility to competitive sport. The failure to detect a significant organic substrate in the initial stage of screening does not preclude the identification of structural pathologies in the follow-up by using advanced imaging techniques. Here we report the case of a senior athlete judged not elegible because an arrhythmia with the morphology consistent with the origin of the left ventricle, in which subsequent execution of a cardiac MR and a thoracic CT scan has allowed the identification of an unique association between an area of myocardial damage, probable site of origine of the arrhythma, and a rare aortic malformation.

  4. Routine clinical heart examinations using SQUID magnetocardiography at University of Tsukuba Hospital

    NASA Astrophysics Data System (ADS)

    Inaba, T.; Nakazawa, Y.; Yoshida, K.; Kato, Y.; Hattori, A.; Kimura, T.; Hoshi, T.; Ishizu, T.; Seo, Y.; Sato, A.; Sekiguchi, Y.; Nogami, A.; Watanabe, S.; Horigome, H.; Kawakami, Y.; Aonuma, K.

    2017-11-01

    A 64-channel Nb-based DC-SQUID magnetocardiography (MCG) system was installed at the University of Tsukuba Hospital (UTH) in March 2007 after obtaining Japanese pharmaceutical approval and insurance reimbursement approval. In the period between 2008 and 2016, the total number of patients was 10 085. The heart diseases diagnosed in fetuses as well as adults are mainly atrial arrhythmia, abnormal repolarization, ventricular arrhythmia, and fetal arrhythmia. In most cases of insufficient diagnostic accuracy with electrocardiography, SQUID MCG precisely revealed these heart diseases as an abnormal electrical current distribution. Based on success in routine examinations, SQUID MCG is now an indispensable clinical instrument with diagnostic software tuned up during routine use at UTH.

  5. [Observations and significance of extrasystole in very young athletes].

    PubMed

    Rossini, G; Mazzoli, M; Dalmastri, G; Crescimbeni, L; Berti, P; Arata, G; Losi, G; Martines, G

    1982-01-01

    80 very young football players (from 8 to 12) have been examined for three months by some clinical and instrumental cardiologic tests (starting E.C.G. and after graduated stresses on a football court). The starting E.C.G. showed variable extresystolic arrhythmias in 8 subjects, without any sure signs of a cardiopathy, to point out by deeper tests (such as polygraphic, echocardiographic test and rx heart teleradiography). The above-mentioned arrhythmias felt the effects of training variably, since they regressed in 6 cases, however two subjects needed a pharmacological intervention. They are still talking over the meaning to give to extrasystolic arrhythmias in very young people in evaluation of attitude to agonism and in programming training.

  6. Sleep-related changes in cardiovascular autonomic regulation in left coronary artery ligation rats: Neural mechanism facilitating arrhythmia after myocardial infarction.

    PubMed

    Lin, Wei-Lun; Lo, Li-Wei; Chen, Hau-Ruey; Lai, Chun-Ting; Yamada, Shinya; Liu, Shin-Huei; Chou, Yu-Hui; Chen, Shih-Ann; Fu, Yun-Ching; Kuo, Terry B J

    2016-12-15

    Autonomic imbalance with increased sympathetic and decreased parasympathetic activities is observed in patients after myocardial infarction (MI). We aimed to investigate sleep-related changed in autonomic regulation in left coronary artery (LCA) ligation rats. Wireless transmission of polysomnographic recording was performed in sham and LCA ligation male rats during normal daytime sleep with and without atenolol treatment. Spectral analyses of the electroencephalogram (EEG) and electromyogram (EMG) were evaluated to define active waking (AW), quiet and paradoxical sleeps (QS, PS). Cardiac autonomic activities were measured by analyzing the power spectrum of heart rate variability (HRV). EEG, EMG and HRV were recorded over 6h for consecutive 3days in all groups. In LCA ligation group, there were higher LF and LF/HF ratio on QS phase, but not AW and PS phases, compared to atenolol treated sham and LCA ligation groups, respectively. The HF component was not significantly changed on all groups in both sleep and awake phases. Sleep interruption was more frequent in LCA ligation rats compared to sham, and it was not found in LCA ligation with atenolol treatment group. Increased AW, PS and decreased QS time were noted in LCA ligation group, compared to sham and it was restored to baseline in LCA ligation with atenolol treatment group. Our results demonstrate significant sleep fragmentations with sympathetic hyperactivity during QS stages after MI, and atenolol could restore the autonomic dysfunction and sleep disturbance. The finding explains the cause of sleep-related fetal arrhythmia and sudden cardiac death after MI. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  7. Sodium channels in the Cx43 gap junction perinexus may constitute a cardiac ephapse: an experimental and modeling study.

    PubMed

    Veeraraghavan, Rengasayee; Lin, Joyce; Hoeker, Gregory S; Keener, James P; Gourdie, Robert G; Poelzing, Steven

    2015-10-01

    It has long been held that electrical excitation spreads from cell-to-cell in the heart via low resistance gap junctions (GJ). However, it has also been proposed that myocytes could interact by non-GJ-mediated "ephaptic" mechanisms, facilitating propagation of action potentials in tandem with direct GJ-mediated coupling. We sought evidence that such mechanisms contribute to cardiac conduction. Using super-resolution microscopy, we demonstrate that Nav1.5 is localized within 200 nm of the GJ plaque (a region termed the perinexus). Electron microscopy revealed close apposition of adjacent cell membranes within perinexi suggesting that perinexal sodium channels could function as an ephapse, enabling ephaptic cell-to-cell transfer of electrical excitation. Acute interstitial edema (AIE) increased intermembrane distance at the perinexus and was associated with preferential transverse conduction slowing and increased spontaneous arrhythmia incidence. Inhibiting sodium channels with 0.5 μM flecainide uniformly slowed conduction, but sodium channel inhibition during AIE slowed conduction anisotropically and increased arrhythmia incidence more than AIE alone. Sodium channel inhibition during GJ uncoupling with 25 μM carbenoxolone slowed conduction anisotropically and was also highly proarrhythmic. A computational model of discretized extracellular microdomains (including ephaptic coupling) revealed that conduction trends associated with altered perinexal width, sodium channel conductance, and GJ coupling can be predicted when sodium channel density in the intercalated disk is relatively high. We provide evidence that cardiac conduction depends on a mathematically predicted ephaptic mode of coupling as well as GJ coupling. These data suggest opportunities for novel anti-arrhythmic therapies targeting noncanonical conduction pathways in the heart.

  8. Computationally efficient method for localizing the spiral rotor source using synthetic intracardiac electrograms during atrial fibrillation.

    PubMed

    Shariat, M H; Gazor, S; Redfearn, D

    2015-08-01

    Atrial fibrillation (AF), the most common sustained cardiac arrhythmia, is an extremely costly public health problem. Catheter-based ablation is a common minimally invasive procedure to treat AF. Contemporary mapping methods are highly dependent on the accuracy of anatomic localization of rotor sources within the atria. In this paper, using simulated atrial intracardiac electrograms (IEGMs) during AF, we propose a computationally efficient method for localizing the tip of the electrical rotor with an Archimedean/arithmetic spiral wavefront. The proposed method deploys the locations of electrodes of a catheter and their IEGMs activation times to estimate the unknown parameters of the spiral wavefront including its tip location. The proposed method is able to localize the spiral as soon as the wave hits three electrodes of the catheter. Our simulation results show that the method can efficiently localize the spiral wavefront that rotates either clockwise or counterclockwise.

  9. Discrete event simulation model of sudden cardiac death predicts high impact of preventive interventions.

    PubMed

    Andreev, Victor P; Head, Trajen; Johnson, Neil; Deo, Sapna K; Daunert, Sylvia; Goldschmidt-Clermont, Pascal J

    2013-01-01

    Sudden Cardiac Death (SCD) is responsible for at least 180,000 deaths a year and incurs an average cost of $286 billion annually in the United States alone. Herein, we present a novel discrete event simulation model of SCD, which quantifies the chains of events associated with the formation, growth, and rupture of atheroma plaques, and the subsequent formation of clots, thrombosis and on-set of arrhythmias within a population. The predictions generated by the model are in good agreement both with results obtained from pathological examinations on the frequencies of three major types of atheroma, and with epidemiological data on the prevalence and risk of SCD. These model predictions allow for identification of interventions and importantly for the optimal time of intervention leading to high potential impact on SCD risk reduction (up to 8-fold reduction in the number of SCDs in the population) as well as the increase in life expectancy.

  10. Brief Report: Emotion Regulation and Respiratory Sinus Arrhythmia in Autism Spectrum Disorder

    ERIC Educational Resources Information Center

    Guy, Lisa; Souders, Margaret; Bradstreet, Lauren; DeLussey, Christine; Herrington, John D.

    2014-01-01

    Emotion regulation (ER) may be an important transdiagnostic factor for understanding mental and behavioral health given its association with several psychiatric disorders, including autism spectrum disorder (ASD). However, there is limited research on ER in ASD, particularly using biomarkers such as respiratory sinus arrhythmia (RSA). The aim of…

  11. Trajectories of Children's Internalizing Symptoms: The Role of Maternal Internalizing Symptoms, Respiratory Sinus Arrhythmia and Child Sex

    ERIC Educational Resources Information Center

    Wetter, Emily K.; El-Sheikh, Mona

    2012-01-01

    Background: We assessed trajectories of children's internalizing symptoms as predicted by interactions among maternal internalizing symptoms, respiratory sinus arrhythmia (RSA) and child sex. Method: An ethnically and socioeconomically diverse sample of children (n = 251) participated during three study waves. Children's mean ages were 8.23 years…

  12. T-wave alternans and dispersion of the QT interval as risk stratification markers in patients susceptible to sustained ventricular arrhythmias

    NASA Technical Reports Server (NTRS)

    Armoundas, A. A.; Osaka, M.; Mela, T.; Rosenbaum, D. S.; Ruskin, J. N.; Garan, H.; Cohen, R. J.

    1998-01-01

    T-wave alternans and QT dispersion were compared as predictors of the outcome of electrophysiologic study and arrhythmia-free survival in patients undergoing electrophysiologic evaluation. T-wave alternans was a highly significant predictor of these 2 outcome variables, whereas QT dispersion was not.

  13. TRPA1 and Sympathetic Activation contribute to increased risk of triggered cardiac arrhythmias in hypertensive rats exposed to diesel exhaust

    EPA Science Inventory

    Background -Diesel exhaust (DE), which is emitted from on-and off-road sources, is a complex mixture of toxic gaseous and particulate components that results in adverse cardiovascular effects. Arrhythmias, which are often triggered in the hours and days following exposure, are on...

  14. Effect of low oral doses of disopyramide and amiodarone on ventricular and atrial arrhythmias of chagasic patients with advanced myocardial damage.

    PubMed

    Carrasco, H A; Vicuña, A V; Molina, C; Landaeta, A; Reynosa, J; Vicuña, N; Fuenmayor, A; López, F

    1985-12-01

    Low-dose (7 mg/kg per day) disopyramide administration to arrhythmic chagasic patients decreased the frequency of ventricular extrasystoles in 4 of 17 patients (24%) and suppressed most complex ventricular arrhythmias in 12 of 15 patients (80%). This assessment was made from 72-h continuous Holter monitoring recorded during the course of this double blind, placebo-controlled randomized crossover study. Seven patients (41%) complained of anticholinergic side effects, but no contractile or conduction system depression was seen. Amiodarone (200 mg) given on a single blind, placebo-controlled basis to 9 of these patients reduced the frequency of ventricular extrasystoles in 6 of 9 patients (67%) and suppressed complex ventricular ectopy in 6 of 7 patients (85%). One patient was unable to tolerate this drug (11%). Both drugs seemed less effective in controlling supraventricular arrhythmias, although disopyramide eliminated paroxysms of supraventricular tachycardia in 9 of 13 (69%) and amiodarone in all 6 patients with this arrhythmia. Amiodarone appears to be a better antiarrhythmic drug for chagasic patients, due to its greater effectiveness and lower incidence of side effects.

  15. Recurrent syncope attributed to left main coronary artery severe stenosis.

    PubMed

    Li, Min; Zheng, Xinyi; Liu, Hua; Liu, Yujie

    2015-01-01

    Patients with acute coronary syndrome (ACS) rarely manifest as recurrent syncope due to malignant ventricular arrhythmia. We report a case of a 56-year-old Chinese male with complaints of paroxysmal chest burning sensation and distress for 2 weeks as well as loss of consciousness for 3 days. The electrocardiogram (ECG) revealed paroxysmal multimorphologic ventricular tachycardia during attack and normal heart rhythm during intervals. Coronary angiograph showed 90% stenosis in left main coronary artery and 80% stenosis in anterior descending artery. Two stents sized 4.0∗18 mm and 2.75∗18 mm were placed at left main coronary artery and anterior descending artery, respectively, during percutaneous coronary intervention (PCI). The patient was discharged and never had ventricular arrhythmia again during a 3-month follow-up since the PCI. This indicated that ventricular tachycardia was correlated with persistent severe myocardial ischemia. Coronary vasospasm was highly suspected to be the reason of the sudden attack and acute exacerbation. PCI is recommended in patients with both severe coronary artery stenosis and ventricular arrhythmia. Removing myocardial ischemia may stop or relieve ventricular arrhythmia and prevent cardiac arrest.

  16. Genetic testing and genetic counseling in patients with sudden death risk due to heritable arrhythmias.

    PubMed

    Spoonamore, Katherine G; Ware, Stephanie M

    2016-03-01

    Sudden cardiac death due to heritable ventricular arrhythmias is an important cause of mortality, especially in young healthy individuals. The identification of the genetic basis of Mendelian diseases associated with arrhythmia has allowed the integration of this information into the diagnosis and clinical management of patients and at-risk family members. The rapid expansion of genetic testing options and the increasing complexity involved in the interpretation of results creates unique opportunities and challenges. There is a need for competency to incorporate genetics into clinical management and to provide appropriate family-based risk assessment and information. In addition, disease-specific genetic knowledge is required to order and correctly interpret and apply genetic testing results. Importantly, genetic diagnosis has a critical role in the risk stratification and clinical management of family members. This review summarizes the approach to genetic counseling and genetic testing for inherited arrhythmias and highlights specific genetic principles that apply to long QT syndrome, short QT syndrome, Brugada syndrome, and catecholaminergic polymorphic ventricular tachycardia. Copyright © 2016 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  17. Intermittent bradyarrhythmia in a Hispaniolan Amazon parrot (Amazona ventralis).

    PubMed

    Rembert, Melanie S; Smith, Julie A; Strickland, Keith N; Tully, Thomas N

    2008-03-01

    A clinically normal 2-year-old Hispaniolan Amazon parrot (Amazona ventralis) was found to have periodic second-degree atrioventricular (AV) block with variable nodal conductions while anesthetized with isoflurane during a thermal-support research project. Arrhythmias were observed on 5 successive weekly electrocardiograms. A complete cardiac evaluation, including a diagnostic electrocardiogram, revealed intermittent bradyarrhythmias ranging from a 2:1 to a 7:1 second-degree AV block, with concurrent hypotensive episodes during the nodal blocks. Results of a complete blood cell count, plasma biochemical profile, blood gas analysis, and atropine-response test, as well as radiography and auscultation, revealed no obvious cause for the arrhythmias. Echocardiography demonstrated cardiac wall thickness, chamber size, and systolic function similar to other psittacine birds. On return to the colony, the parrot continued to be outwardly asymptomatic despite the dramatic conduction disturbances. Although cardiac arrhythmias, including second-degree AV block, have been widely reported in birds, the wide variation of nodal conductions, the intermittent nature, and an arrhythmia with a 7:1 second-degree AV block that spontaneously reverts to normal as seen in this case have not been well documented in parrots.

  18. Symmetrical compression distance for arrhythmia discrimination in cloud-based big-data services.

    PubMed

    Lillo-Castellano, J M; Mora-Jiménez, I; Santiago-Mozos, R; Chavarría-Asso, F; Cano-González, A; García-Alberola, A; Rojo-Álvarez, J L

    2015-07-01

    The current development of cloud computing is completely changing the paradigm of data knowledge extraction in huge databases. An example of this technology in the cardiac arrhythmia field is the SCOOP platform, a national-level scientific cloud-based big data service for implantable cardioverter defibrillators. In this scenario, we here propose a new methodology for automatic classification of intracardiac electrograms (EGMs) in a cloud computing system, designed for minimal signal preprocessing. A new compression-based similarity measure (CSM) is created for low computational burden, so-called weighted fast compression distance, which provides better performance when compared with other CSMs in the literature. Using simple machine learning techniques, a set of 6848 EGMs extracted from SCOOP platform were classified into seven cardiac arrhythmia classes and one noise class, reaching near to 90% accuracy when previous patient arrhythmia information was available and 63% otherwise, hence overcoming in all cases the classification provided by the majority class. Results show that this methodology can be used as a high-quality service of cloud computing, providing support to physicians for improving the knowledge on patient diagnosis.

  19. [The contribution of inflammatory process in pathogenesis and natural history of atrial fibrillation].

    PubMed

    Zyśko, Dorota; Gajek, Jacek; Mazurek, Walentyna

    2005-02-01

    The inflammatory process plays important role in pathogenesis of some cardiovascular diseases. Atrial fibrillation is atrial arrhythmia with rapid, asynchronous activation of atrial myocytes. The inflammatory process can be responsible for atrial electrical and anatomical remodeling and therefore shifts towards arrhythmia persistence. The presence of systemic inflammation may be assessed by means of C-reactive protein (CRP) measurement. Maximal concentration of CRP coincidences with the peak of paroxysmal atrial fibrillation occurrence in patients after cardiac surgery. In patients with sinus rhythm the concentration of CRP is a risk factor for this arrhythmia in long-term follow-up. In patients with atrial fibrillation mean CRP concentration is 2-fold higher comparing to control group. CRP concentration is higher in patients with chronic than paroxysmal form of this arrhythmia. High CRP level predicts worse results of direct current cardioversion and more frequent paroxysms of atrial fibrillation during follow-up. Besides of, the patients with echocardiographic signs of thromboembolic risk have higher CRP levels than control subjects. There is no data about the influence of anti-inflammatory therapy on atrial fibrillation or its recurrences.

  20. Arrhythmia Classification Based on Multi-Domain Feature Extraction for an ECG Recognition System.

    PubMed

    Li, Hongqiang; Yuan, Danyang; Wang, Youxi; Cui, Dianyin; Cao, Lu

    2016-10-20

    Automatic recognition of arrhythmias is particularly important in the diagnosis of heart diseases. This study presents an electrocardiogram (ECG) recognition system based on multi-domain feature extraction to classify ECG beats. An improved wavelet threshold method for ECG signal pre-processing is applied to remove noise interference. A novel multi-domain feature extraction method is proposed; this method employs kernel-independent component analysis in nonlinear feature extraction and uses discrete wavelet transform to extract frequency domain features. The proposed system utilises a support vector machine classifier optimized with a genetic algorithm to recognize different types of heartbeats. An ECG acquisition experimental platform, in which ECG beats are collected as ECG data for classification, is constructed to demonstrate the effectiveness of the system in ECG beat classification. The presented system, when applied to the MIT-BIH arrhythmia database, achieves a high classification accuracy of 98.8%. Experimental results based on the ECG acquisition experimental platform show that the system obtains a satisfactory classification accuracy of 97.3% and is able to classify ECG beats efficiently for the automatic identification of cardiac arrhythmias.

  1. Assessing ECG signal quality indices to discriminate ECGs with artefacts from pathologically different arrhythmic ECGs.

    PubMed

    Daluwatte, C; Johannesen, L; Galeotti, L; Vicente, J; Strauss, D G; Scully, C G

    2016-08-01

    False and non-actionable alarms in critical care can be reduced by developing algorithms which assess the trueness of an arrhythmia alarm from a bedside monitor. Computational approaches that automatically identify artefacts in ECG signals are an important branch of physiological signal processing which tries to address this issue. Signal quality indices (SQIs) derived considering differences between artefacts which occur in ECG signals and normal QRS morphology have the potential to discriminate pathologically different arrhythmic ECG segments as artefacts. Using ECG signals from the PhysioNet/Computing in Cardiology Challenge 2015 training set, we studied previously reported ECG SQIs in the scientific literature to differentiate ECG segments with artefacts from arrhythmic ECG segments. We found that the ability of SQIs to discriminate between ECG artefacts and arrhythmic ECG varies based on arrhythmia type since the pathology of each arrhythmic ECG waveform is different. Therefore, to reduce the risk of SQIs classifying arrhythmic events as noise it is important to validate and test SQIs with databases that include arrhythmias. Arrhythmia specific SQIs may also minimize the risk of misclassifying arrhythmic events as noise.

  2. Arrhythmia Classification Based on Multi-Domain Feature Extraction for an ECG Recognition System

    PubMed Central

    Li, Hongqiang; Yuan, Danyang; Wang, Youxi; Cui, Dianyin; Cao, Lu

    2016-01-01

    Automatic recognition of arrhythmias is particularly important in the diagnosis of heart diseases. This study presents an electrocardiogram (ECG) recognition system based on multi-domain feature extraction to classify ECG beats. An improved wavelet threshold method for ECG signal pre-processing is applied to remove noise interference. A novel multi-domain feature extraction method is proposed; this method employs kernel-independent component analysis in nonlinear feature extraction and uses discrete wavelet transform to extract frequency domain features. The proposed system utilises a support vector machine classifier optimized with a genetic algorithm to recognize different types of heartbeats. An ECG acquisition experimental platform, in which ECG beats are collected as ECG data for classification, is constructed to demonstrate the effectiveness of the system in ECG beat classification. The presented system, when applied to the MIT-BIH arrhythmia database, achieves a high classification accuracy of 98.8%. Experimental results based on the ECG acquisition experimental platform show that the system obtains a satisfactory classification accuracy of 97.3% and is able to classify ECG beats efficiently for the automatic identification of cardiac arrhythmias. PMID:27775596

  3. Intracellular magnesium concentrations in dogs with gastric dilatation-volvulus.

    PubMed

    Bebchuk, T N; Hauptman, J G; Braselton, W E; Walshaw, R

    2000-11-01

    To quantify and compare intracellular magnesium concentrations (Mgi) in clinically normal dogs (control dogs) and dogs that have gastric dilatation-volvulus (GDV dogs) and to determine whether there is a difference in Mgi and serum magnesium concentrations (Mgs) between GDV dogs with and without cardiac arrhythmias. 41 control dogs and 21 GDV dogs. Rectus abdominis muscle specimens were obtained from control and GDV dogs for determination of Mgi. Blood samples were obtained from GDV dogs for determination of Mgs, and dogs were monitored for 48 hours for cardiac arrhythmias. Muscle specimens were frozen at -40 C, oven dried at 95 C, and digested with concentrated nitric acid. Multielemental analyses were performed by simultaneous/sequential inductively coupled plasma-atomic emission spectroscopy with fixed-cross flow nebulization. The Mg, was standardized to sulfur content to correct for the amount of fat and fascia in the muscle specimen. Mean (+/- SEM) values were recorded in parts per million (ppm). Results-There were no significant differences in Mgi between control (627 +/- 11.1 ppm) and GDV (597 +/- 20.5 ppm) dogs, in Mgi between GDV dogs with (590 +/- 34 ppm) and without (584 +/- 29 ppm) cardiac arrhythmias, and in Mgs between GDV dogs with (1.77 +/- 0.26 ppm) and without (1.51 +/- 0.09 ppm) cardiac arrhythmias. There was no correlation between Mgs and Mgi (R2 = 0.0001). Results indicate that Mg depletion is not pathophysiologically important in dogs with GDV and does not play a role in the cardiac arrhythmias detected in these patients.

  4. Dynamic Changes of QRS Morphology of Premature Ventricular Contractions During Ablation in the Right Ventricular Outflow Tract: A Case Report.

    PubMed

    Yue-Chun, Li; Jia-Feng, Lin; Jia-Xuan, Lin

    2015-10-01

    Electrocardiographic characteristics can be useful in differentiating between right ventricular outflow tract (RVOT) and aortic sinus cusp (ASC) ventricular arrhythmias. Ventricular arrhythmias originating from ASC, however, show preferential conduction to RVOT that may render the algorithms of electrocardiographic characteristics less reliable. Even though there are few reports describing ventricular arrhythmias with ASC origins and endocardial breakout sites of RVOT, progressive dynamic changes in QRS morphology of the ventricular arrhythmias during ablation obtained were rare.This case report describes a patient with symptomatic premature ventricular contractions of left ASC origin presenting an electrocardiogram (ECG) characteristic of right ventricular outflow tract before ablation. Pacing at right ventricular outflow tract reproduced an excellent pace map. When radiofrequency catheter ablation was applied to the right ventricular outflow tract, the QRS morphology of premature ventricular contractions progressively changed from ECG characteristics of right ventricular outflow tract origin to ECG characteristics of left ASC origin.Successful radiofrequency catheter ablation was achieved at the site of the earliest ventricular activation in the left ASC. The distance between the successful ablation site of the left ASC and the site with an excellent pace map of the RVOT was 20 mm.The ndings could be strong evidence for a preferential conduction via the myocardial bers from the ASC origin to the breakout site in the right ventricular outflow tract. This case demonstrates that ventricular arrhythmias with a single origin and exit shift may exhibit QRS morphology changes.

  5. The association of ambient temperature with incidence of cardiac arrhythmias in a short timescale

    NASA Astrophysics Data System (ADS)

    Kim, Jayeun; Kim, Ho

    2017-11-01

    The body response time and an association between the exposure to outdoor temperature and cardiac arrhythmia were not fully understood. Hence, we further investigated the association between ambient temperature and the exacerbations of arrhythmia symptoms on a short timescale using the emergency department (ED) visit data. We used a total of 17,088 arrhythmia-related ED visits in Seoul, from 2008 to 2011 and fitted the model adjusting for other meteorological variables and air pollutants under the case-crossover analysis with the same year-month time stratification. The association was presented as an odds ratio (OR) with a 95% confidence interval (CI) by a 5 °C decrease in the ambient temperature. The delay time (h) between exposure and the onset of arrhythmia exacerbation was considered with time blocks for every 3 h as 1-3 h, up to 118-120 h; and daily lags (1 day), from 25-48 h to 97-120 h, as a multi-time average of exposures. The overall association was increased at lag 4-6 h and the increased association was statistically significant at lag 40-42 h (OR 1.027, 95% CI 1.003-1.051) and the adverse association continued at 97-120 h (OR 1.053, 95% CI 1.027-1.080). However, the delay of several days between ambient temperature and body response should be further investigated considering the modification according to varied demographic characteristics or different environmental circumstances.

  6. Reversible atrial fibrillation following Crotalinae envenomation.

    PubMed

    Quan, Dan; Zurcher, Kenneth

    2017-01-01

    Cardiotoxicity is a documented complication of Crotalinae envenomation. Reported cardiac complications following snake envenomation have included acute myocardial infarction, electrocardiogram abnormalities and arrhythmias. Few reports exist describing arrhythmia induced by viper envenomation and to our knowledge none describe arrhythmia induced by Crotalinae envenomation. This report concerns the first known case of atrial fibrillation precipitated by rattlesnake bite. A 73-year-old Caucasian man with a past medical history of hypertension, hyperlipidemia, type 1 diabetes mellitus, and a baseline first-degree atrioventricular block presented to the emergency department following a rattlesnake bite to his left lower leg. He developed pain and swelling in his left leg two-hour post-envenomation and subsequently received four vials of Crotalidae polyvalent immune fab (ovine). At three-hour post-envenomation following transfer to the intensive care unit, an electrocardiogram revealed new-onset atrial fibrillation. An amiodarone drip was started and the patient successfully converted to normal sinus rhythm approximately six hours after he was found to be in atrial fibrillation. A transthoracic echocardiogram revealed mild concentric left ventricular hypertrophy and an ejection fraction of 72%. He was discharged the following day with no hematological abnormalities and a baseline first-degree atrioventricular block. This is the first documented case of reversible atrial fibrillation precipitated by Crotalinae envenomation. In patients with pertinent risk factors for developing atrial fibrillation, physicians should be aware of the potential for this arrhythmia. Direct toxic effects of venom or structural and electrophysiological cardiovascular abnormalities may predispose snakebite patients to arrhythmia, warranting extended and attentive cardiac monitoring.

  7. Arrhythmia-induced cardiomyopathies: the riddle of the chicken and the egg still unanswered?

    PubMed

    Simantirakis, Emmanuel N; Koutalas, Emmanuel P; Vardas, Panos E

    2012-04-01

    The hypothesis testing of inappropriate fast, irregular, or asynchronous myocardial contraction provoking cardiomyopathy has been the primary focus of numerous research efforts, especially during the last few decades. Rapid ventricular rates resulting from supraventricular arrhythmias and atrial fibrillation (AF), irregularity of heart rhythm-basic element of AF-and asynchrony, as a consequence of right ventricular pacing, bundle branch block, or frequent premature ventricular complexes, have been established as primary causes of arrhythmia-induced cardiomyopathy. The main pathophysiological pathways involved have been clarified, including neurohumoral activation, energy stores depletion, and abnormalities in stress and strain. Unfortunately, from a clinical point of view, patients usually seek medical advice only when symptoms develop, while the causative arrhythmia may be present for months or years, resulting in myocardial remodelling, diastolic, and systolic dysfunction. In some cases, making a definite diagnosis may become a strenuous exercise for the treating physician, as the arrhythmia may not be present and, additionally, therapy must be applied for the diagnosis to be confirmed retrospectively. The diagnostic process is also hardened due to the fact that strict diagnosing criteria are still a matter of discrepancy. Therapy options include pharmaceutical agents trials, catheter-based therapies and, in the context of chronic ventricular pacing, resynchronization. For the majority of patients, partial or complete recovery is expected, although they have to be followed up thoroughly due to the risk of recurrence. Large, randomized controlled trials are more than necessary to optimize patients' stratification and therapeutic strategy choices.

  8. Anesthetic implications of primary cardiac tumors in infants and children.

    PubMed

    Kussman, Barry D; Devavaram, Prabhakar; Hansen, Dolly D; Dinardo, James A; Forbess, Joseph M; Mehrota, Ramji; McGowan, Francis X

    2002-10-01

    To determine the degree of hemodynamic and airway compromise in infants and children undergoing anesthesia for primary cardiac tumors. Retrospective study. Tertiary-care, academic children's hospital. Patients <18 years old who had undergone anesthesia and surgery for resection or biopsy of a primary cardiac tumor (n = 25). None. Charts were reviewed for intraoperative complications, defined as (1) hypotension (20% decrease from baseline) during or after induction; (2) failure to gain airway control by insertion of an airway or endotracheal intubation, inability to ventilate after administration of a muscle relaxant, need for change in patient position, rigid bronchoscopy, or cardiopulmonary bypass for adequate oxygenation; and (3) new arrhythmias. Hypotension during induction occurred in 4 patients (16%), 3 of whom were hemodynamically unstable preoperatively. Hypotension after induction was found in 2 (8%) patients. Hypotension occurred more frequently in patients with obstruction to blood flow and arrhythmia (n = 3), obstruction to blood flow only (n = 1), and arrhythmia only (n = 1). No patient had airway difficulty related to the tumor, although one intrapericardial tumor mimicked an anterior mediastinal mass. New arrhythmias occurred in 3 (12%) patients. The subgroup of patients at greatest risk are patients with a combination of obstruction to blood flow and arrhythmias. Despite the alarming diagnosis, the intraoperative course tends to be fairly stable in most cases. Extensive pericardial tumors may produce the same airway concerns as anterior mediastinal masses, but airway complications do not seem to be a problem with intrachamber tumors. Copyright 2002, Elsevier Science (USA). All rights reserved.

  9. Ablation of post-surgical intra-atrial reentrant tachycardia. Predilection target sites and mapping approach.

    PubMed

    Anné, W; van Rensburg, H; Adams, J; Ector, H; Van de Werf, F; Heidbüchel, H

    2002-10-01

    Atrial arrhythmias are a frequent complication of atrial surgery. The location of these tachycardias is very diverse due to the individual difference in the original anatomy, surgical corrections, and effects of atrial fibrosis. Nevertheless some recurrent patterns are emerging. Forty-five patients underwent 51 ablation procedures between September 1995 and March 2001 using conventional mapping and temperature-controlled ablation. A duadecapolar catheter was swept from anterior to posterior in the right (and/or left) atrium, allowing for rapid mapping followed by entrainment confirmation. Twenty-eight patients had corrected congenital heart disease, 17 surgery for acquired heart disease. One hundred and sixteen arrhythmias were found, 86 circuits were targeted, 81 with success (94%). Despite the heterogeneous anatomy, the same targets were often encountered: the posterior isthmus between the inferior vena cava and the tricuspid ring (62%), the gap between the inferior vena cava and the atriotomy scar (49%), and the region around the atriopulmonary connection in Fontans (two out of four patients). After a mean follow-up of 24 months, 13 patients had a recurrent arrhythmia (29%) after their last procedure. There was a significant association between the number of circuits found during the initial procedure and the likelihood of recurrent arrhythmias. Knowledge of anatomical predilection sites and mapping the right (and/or left) atrium with a 'sweeping Halo technique' allow for effective ablation of most post-surgical atrial tachycardias. Severely damaged atria with multiple arrhythmias may require 'preventive' ablation of all recognizable channels.

  10. Comparison of two teaching methods for cardiac arrhythmia interpretation among nursing students.

    PubMed

    Varvaroussis, Dimitrios P; Kalafati, Maria; Pliatsika, Paraskevi; Castrén, Maaret; Lott, Carsten; Xanthos, Theodoros

    2014-02-01

    The aim of this study was to compare the six-stage method (SSM) for instructing primary cardiac arrhythmias interpretation to students without basic electrocardiogram (ECG) knowledge with a descriptive teaching method in a single educational intervention. This is a randomized trial. Following a brief instructional session, undergraduate nursing students, assigned to group A (SSM) and group B (descriptive teaching method), undertook a written test in cardiac rhythm recognition, immediately after the educational intervention (initial exam). Participants were also examined with an unannounced retention test (final exam), one month after instruction. Altogether 134 students completed the study. Interpretation accuracy for each cardiac arrhythmia was assessed. Mean score at the initial exam was 8.71±1.285 for group A and 8.74±1.303 for group B. Mean score at the final exam was 8.25±1.46 for group A vs 7.84±1.44 for group B. Overall results showed that the SSM was equally effective with the descriptive teaching method. The study showed that in each group bradyarrhythmias were identified correctly by more students than tachyarrhythmias. No significant difference between the two teaching methods was seen for any specific cardiac arrhythmia. The SSM effectively develops staff competency for interpreting common cardiac arrhythmias in students without ECG knowledge. More research is needed to support this conclusion and the method's effectiveness must be evaluated if being implemented to trainee groups with preexisting basic ECG interpretation knowledge. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  11. Ventricular arrhythmias in the absence of structural heart disease.

    PubMed

    Prystowsky, Eric N; Padanilam, Benzy J; Joshi, Sandeep; Fogel, Richard I

    2012-05-15

    Ventricular arrhythmia (VA) in structurally normal hearts can be broadly considered under non-life-threatening monomorphic and life-threatening polymorphic rhythms. Monomorphic VA is classified on the basis of site of origin in the heart, and the most common areas are the ventricular outflow tracts and left ventricular fascicles. The morphology of the QRS complexes on electrocardiogram is an excellent tool to identify the site of origin of the rhythm. Although these arrhythmias are common and generally carry an excellent prognosis, rare sudden death events have been reported. Very frequent ventricular ectopy may also result in a cardiomyopathy in a minority of patients. Suppression of VA may be achieved using calcium-channel blockers, beta-adrenergic blockers, and class I or III antiarrhythmic drugs. Radiofrequency ablation has emerged as an excellent option to eliminate these arrhythmias, although certain foci including aortic cusps and epicardium may be technically challenging. Polymorphic ventricular tachycardia (VT) is rare and generally occurs in patients with genetic ion channel disorders including long QT syndrome, Brugada syndrome, catecholaminergic polymorphic VT, and short QT syndrome. Unlike monomorphic VT, these arrhythmic syndromes are associated with sudden death. While the cardiac gross morphology is normal, suggesting a structurally normal heart, abnormalities exist at the molecular level and predispose them to arrhythmias. Another fascinating area, idiopathic ventricular fibrillation and early repolarization syndrome, are undergoing research for a genetic basis. Copyright © 2012 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  12. Prevention of ventricular arrhythmia and calcium dysregulation in a catecholaminergic polymorphic ventricular tachycardia mouse model carrying calsequestrin-2 mutation.

    PubMed

    Alcalai, Ronny; Wakimoto, Hiroko; Arad, Michael; Planer, David; Konno, Tetsuo; Wang, Libin; Seidman, Jon G; Seidman, Christine E; Berul, Charles I

    2011-03-01

    Catecholaminergic polymorphic ventricular tachycardia (CPVT) is a familial arrhythmic syndrome caused by mutations in genes encoding the calcium-regulation proteins cardiac ryanodine receptor (RyR2) or calsequestrin-2 (CASQ2). Mechanistic studies indicate that CPVT is mediated by diastolic Ca(2+) overload and increased Ca(2+) leak through the RyR2 channel, implying that treatment targeting these defects might be efficacious in CPVT. CPVT mouse models that lack CASQ2 were treated with Ca(2+) -channel inhibitors, β-adrenergic inhibitors, or Mg(2+) . Treatment effects on ventricular arrhythmia, sarcoplasmic reticulum (SR) protein expression and Ca(2+) transients of isolated myocytes were assessed. Each study agent reduced the frequency of stress-induced ventricular arrhythmia in mutant mice. The Ca(2+) channel blocker verapamil was most efficacious and completely prevented arrhythmia in 85% of mice. Verapamil significantly increased the SR Ca(2+) content in mutant myocytes, diminished diastolic Ca(2+) overload, increased systolic Ca(2+) amplitude, and prevented Ca(2+) oscillations in stressed mutant myocytes. Ca(2+) channel inhibition by verapamil rectified abnormal calcium handling in CPVT myocytes and prevented ventricular arrhythmias. Verapamil-induced partial normalization of SR Ca(2+) content in mutant myocytes implicates CASQ2 as modulator of RyR2 activity, rather than or in addition to, Ca(2+) buffer protein. Agents such as verapamil that attenuate cardiomyocyte calcium overload are appropriate for assessing clinical efficacy in human CPVT. © 2010 Wiley Periodicals, Inc.

  13. Prevention of Ventricular Arrhythmia and Calcium Dysregulation in a Catecholaminergic Polymorphic Ventricular Tachycardia Mouse Model Carrying Calsequestrin-2 Mutation

    PubMed Central

    Alcalai, Ronny; Wakimoto, Hiroko; Arad, Michael; Planer, David; Konno, Tetsuo; Wang, Libin; Seidman, Jon G.; Seidman, Christine E.; Berul, Charles I

    2010-01-01

    Background Catecholaminergic polymorphic ventricular tachycardia (CPVT) is a familial arrhythmic syndrome caused by mutations in genes encoding the calcium-regulation proteins cardiac ryanodine receptor (RyR2) or calsequestrin-2 (CASQ2). Mechanistic studies indicate that CPVT is mediated by diastolic Ca2+ overload and increased Ca2+ leak through the RyR2 channel, implying that treatment targeting these defects might be efficacious in CPVT. Method and results CPVT mouse models that lack CASQ2 were treated with Ca2+-channel inhibitors, β-adrenergic inhibitors, or Mg2+. Treatment effects on ventricular arrhythmia, sarcoplasmic reticulum (SR) protein expression and Ca2+ transients of isolated myocytes were assessed. Each study agent reduced the frequency of stress-induced ventricular arrhythmia in mutant mice. The Ca2+ channel blocker verapamil was most efficacious and completely prevented arrhythmia in 85% of mice. Verapamil significantly increased the SR Ca2+ content in mutant myocytes, diminished diastolic Ca2+ overload, increased systolic Ca2+ amplitude, and prevented Ca2+ oscillations in stressed mutant myocytes. Conclusions Ca2+ channel inhibition by verapamil rectified abnormal calcium handling in CPVT myocytes and prevented ventricular arrhythmias. Verapamil-induced partial normalization of SR Ca2+ content in mutant myocytes implicates CASQ2 as modulator of RyR2 activity, rather than or in addition to, Ca2+ buffer protein. Agents such as verapamil that attenuate cardiomyocyte calcium overload are appropriate for assessing clinical efficacy in human CPVT. PMID:20807279

  14. Thromboprophylaxis for atrial arrhythmias in congenital heart disease: A multicenter study.

    PubMed

    Khairy, Paul; Aboulhosn, Jamil; Broberg, Craig S; Cohen, Scott; Cook, Stephen; Dore, Annie; Fernandes, Susan M; Fournier, Anne; Kay, Joseph; Levesque, Sylvie; Macle, Laurent; Marcotte, François; Mondésert, Blandine; Mongeon, François-Pierre; Opotowsky, Alexander R; Proietti, Anna; Rivard, Lena; Ting, Jennifer; Thibault, Bernard; Zaidi, Ali; Hamilton, Robert

    2016-11-15

    There is a paucity of data to guide decisions regarding thromboprophylaxis for atrial arrhythmias in congenital heart disease. A retrospective multicenter cohort study enrolled patients with documented sustained atrial arrhythmias and congenital heart disease from 12 North American centers to quantify thromboembolic and bleeding rates associated with antiplatelet and anticoagulation therapy, and explore associated factors. A blinded committee adjudicated all qualifying arrhythmias and outcomes. A total of 482 patients, 45.2% female, age 32.0±18.0years, were followed for 11.3±9.4years since the qualifying arrhythmia. Antiplatelet therapy was administered to 37.8%, anticoagulation to 54.4%, and neither to 7.9%. Congenital heart disease complexity was simple, moderate, and severe in 18.5%, 34.4%, and 47.1%, respectively. Freedom from thromboembolic events was 84.7±2.7% at 15years, with no difference between anticoagulation versus antiplatelet therapy (P=0.97). Congenital heart disease complexity was independently associated with thromboembolic events, with rates of 0.00%, 0.93%, and 1.95%/year in those with simple, moderate, and severe forms (P<0.001). CHADS 2 and CHA 2 DS 2 -VASc scores were not predictive of thromboembolic risk. Annualized bleeding rates with antiplatelet and anticoagulation therapy were 0.66% and 1.82% (P=0.039). In multivariable analyses, anticoagulation [hazard ratio (HR) 4.76, 95% CI (1.05-21.58), P=0.043] and HAS-BLED score [HR 3.15, 95% CI (1.02, 9.78), P=0.047] were independently associated with major bleeds. Current management of atrial arrhythmias in congenital heart disease is associated with a modest rate of thromboembolic events, which is predicted by disease complexity but not CHADS 2 /CHA 2 DS 2 -VASc scores. HAS-BLED score is applicable to the congenital population in predicting major bleeds. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  15. Inhibition of N-type Ca2+ channels ameliorates an imbalance in cardiac autonomic nerve activity and prevents lethal arrhythmias in mice with heart failure.

    PubMed

    Yamada, Yuko; Kinoshita, Hideyuki; Kuwahara, Koichiro; Nakagawa, Yasuaki; Kuwabara, Yoshihiro; Minami, Takeya; Yamada, Chinatsu; Shibata, Junko; Nakao, Kazuhiro; Cho, Kosai; Arai, Yuji; Yasuno, Shinji; Nishikimi, Toshio; Ueshima, Kenji; Kamakura, Shiro; Nishida, Motohiro; Kiyonaka, Shigeki; Mori, Yasuo; Kimura, Takeshi; Kangawa, Kenji; Nakao, Kazuwa

    2014-10-01

    Dysregulation of autonomic nervous system activity can trigger ventricular arrhythmias and sudden death in patients with heart failure. N-type Ca(2+) channels (NCCs) play an important role in sympathetic nervous system activation by regulating the calcium entry that triggers release of neurotransmitters from peripheral sympathetic nerve terminals. We have investigated the ability of NCC blockade to prevent lethal arrhythmias associated with heart failure. We compared the effects of cilnidipine, a dual N- and L-type Ca(2+) channel blocker, with those of nitrendipine, a selective L-type Ca(2+) channel blocker, in transgenic mice expressing a cardiac-specific, dominant-negative form of neuron-restrictive silencer factor (dnNRSF-Tg). In this mouse model of dilated cardiomyopathy leading to sudden arrhythmic death, cardiac structure and function did not significantly differ among the control, cilnidipine, and nitrendipine groups. However, cilnidipine dramatically reduced arrhythmias in dnNRSF-Tg mice, significantly improving their survival rate and correcting the imbalance between cardiac sympathetic and parasympathetic nervous system activity. A β-blocker, bisoprolol, showed similar effects in these mice. Genetic titration of NCCs, achieved by crossing dnNRSF-Tg mice with mice lacking CACNA1B, which encodes the α1 subunit of NCCs, improved the survival rate. With restoration of cardiac autonomic balance, dnNRSF-Tg;CACNA1B(+/-) mice showed fewer malignant arrhythmias than dnNRSF-Tg;CACNA1B(+/+) mice. Both pharmacological blockade of NCCs and their genetic titration improved cardiac autonomic balance and prevented lethal arrhythmias in a mouse model of dilated cardiomyopathy and sudden arrhythmic death. Our findings suggest that NCC blockade is a potentially useful approach to preventing sudden death in patients with heart failure. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.

  16. Trends in Reporting Methadone-Associated Cardiac Arrhythmia, 1997–2011

    PubMed Central

    Kao, David; Bartelson, Becki Bucher; Khatri, Vaishali; Dart, Richard; Mehler, Philip S.; Katz, David; Krantz, Mori J.

    2013-01-01

    Background: Long-acting opioids are a leading cause of accidental death in the United States, and methadone is associated with greater mortality rates. Whether this increase is related to the proarrhythmic properties of methadone is unclear. Objective: To describe methadone-associated arrhythmia events reported in the U.S. Food and Drug Administration Adverse Event Reporting System (FAERS). Design: Description of national adverse event registry data before and after publication of a 2002 report describing an association between methadone and arrhythmia. Setting: FAERS, November 1997 and June 2011. Patients: Adults with QTc prolongation or torsade de pointes and ventricular arrhythmia or cardiac arrest. Measurements: FAERS reports before and after the 2002 report. Results: 1646 cases of ventricular arrhythmia or cardiac arrest and 379 cases of QTc prolongation or torsade de pointes were associated with methadone. Monthly reports of QTc prolongation or torsade de pointes increased from a mean of 0.3 (95% CI, 0.1 to 0.5) before the 2002 publication to a mean of 3.5 (CI, 2.5 to 4.8) after it. After 2000, methadone was the second-most common primary suspect in cases of QTc prolongation or torsade de pointes after dofetilide (a known proarrhythmic drug) and was associated with disproportionate reporting similar to that of antiarrhythmic agents known to promote torsade de pointes. Antiretroviral drugs for HIV were the most common coadministered drugs. Limitation: Reports to FAERs are voluntary and selective, and incidence rates cannot be determined from spontaneously reported data. Conclusion: Since 2002, reports to FAERS of methadone-associated arrhythmia have increased substantially and are disproportionately represented relative to other events with the drug. Coadministration of methadone with antiretrovirals in patients with HIV may pose particular risk. Primary Funding Source: Colorado Clinical and Translational Sciences Institute, National Institutes of Health, and Agency for Healthcare Research and Quality. PMID:23689766

  17. Protective effects of Hawthorn (Crataegus oxyacantha) extract against digoxin-induced arrhythmias in rats.

    PubMed

    Alp, Hayrullah; Soner, Burak Cem; Baysal, Tamer; Şahin, Ayşe Saide

    2015-01-01

    Digitalis preparations are commonly used by children and adults with heart diseases worldwide, although excessive doses may cause cardiac effects. The aim of the study is to evaluate the antiarrhythmic effect of Crataegus oxyacantha extract on digoxin-induced arrhythmias in anesthetized Wistar rats. Control and experimental groups were evaluated for arrhythmias induced by digoxin. Fifteen rats (7 as controls and 8 as the experimental group) were included in the study. The dry fruits of 100 mg Crataegus oxyacantha were extracted by percolation method. Digoxin, at a dose of 40 µg/kg/min, was infused to form the arrhythmias in all rats. Simultaneously, the extract was infused into the experimental group, while 0.9% NaCl was infused into control group. Electrocardiographic QRS prolongation and arterial blood pressure changes were analyzed. The experimental group lived longer (62.13±2.20 min) than the controls (p=0.002). On the other hand, the time to beginning of QRS prolongation did not differ between the two groups (p=0.812). Bradycardia was significant in the control group (288.01±10.54 beat/min and p=0.01). The maximum QRS duration was observed in the control group during the digoxin and 0.9% NaCl infusion period (53.29±3.99 ms and p=0.001). Also, the durations of atrial and ventricular arrhythmias were shorter in the experimental group. However, arterial blood pressure dipping was significant in the experimental group (23.67±10.89 mm Hg and p<0.001). Crataegus oxyacantha alcoholic extract produced an antiarrhythmic effect that was induced by digoxin in Wistar rats. However, in the clinical use of this extract, the hypotensive effect should be considered. Also, the alcoholic extract of Crataegus oxyacantha may be an alternative treatment medication for arrhythmias induced by digoxin toxicity in humans.

  18. Protective effects of Hawthorn (Crataegus oxyacantha) extract against digoxin-induced arrhythmias in rats

    PubMed Central

    Alp, Hayrullah; Soner, Burak Cem; Baysal, Tamer; Şahin, Ayşe Saide

    2016-01-01

    Objective: Digitalis preparations are commonly used by children and adults with heart diseases worldwide, although excessive doses may cause cardiac effects. The aim of the study is to evaluate the antiarrhythmic effect of Crataegus oxyacantha extract on digoxin-induced arrhythmias in anesthetized Wistar rats. Methods: Control and experimental groups were evaluated for arrhythmias induced by digoxin. Fifteen rats (7 as controls and 8 as the experimental group) were included in the study. The dry fruits of 100 mg Crataegus oxyacantha were extracted by percolation method. Digoxin, at a dose of 40 μg/kg/min, was infused to form the arrhythmias in all rats. Simultaneously, the extract was infused into the experimental group, while 0.9% NaCl was infused into control group. Electrocardiographic QRS prolongation and arterial blood pressure changes were analyzed. Results: The experimental group lived longer (62.13±2.20 min) than the controls (p=0.002). On the other hand, the time to beginning of QRS prolongation did not differ between the two groups (p=0.812). Bradycardia was significant in the control group (288.01±10.54 beat/min and p=0.01). The maximum QRS duration was observed in the control group during the digoxin and 0.9% NaCl infusion period (53.29±3.99 ms and p=0.001). Also, the durations of atrial and ventricular arrhythmias were shorter in the experimental group. However, arterial blood pressure dipping was significant in the experimental group (23.67±10.89 mm Hg and p<0.001). Conclusion: Crataegus oxyacantha alcoholic extract produced an antiarrhythmic effect that was induced by digoxin in Wistar rats. However, in the clinical use of this extract, the hypotensive effect should be considered. Also, the alcoholic extract of Crataegus oxyacantha may be an alternative treatment medication for arrhythmias induced by digoxin toxicity in humans. PMID:25880053

  19. [Silent myocardial ischemia and exercise-induced arrhythmia detected by the exercise test in the total health promotion plan (THP)].

    PubMed

    Iwane, M; Shibe, Y; Itoh, K; Kinoshita, F; Kanagawa, Y; Kobayashi, M; Mugitani, K; Ohta, M; Ohata, H; Yoshikawa, A; Ikuta, Z; Nakamura, Y; Mohara, O

    2001-03-01

    We investigated the prevalence and characteristics of ischemic heart disease especially silent myocardial ischemia (SMI) and arrhythmia in need of careful observation in the exercise stress tests in the Total Health Promotion Plan (THP), which was conducted between 1994-96 for the purpose of measuring cardiopulmonary function. All workers (n = 4,918, 4,426 males) aged 18-60 yr old in an occupational field were studied. Exercise tests with an ergometer were performed by the LOPS protocol, in which the maximal workload was set up as a presumed 70-80% maximal oxygen intake, or STEP (original multistage protocol). ECG changes were evaluated with a CC5 lead. Two hundred and fifteen people refused the study because of a common cold, lumbago and so on. Of 4,703 subjects, 17 with abnormal rest ECG and 19 with probable anginal pain were excluded from the exercise tests. Of 4,667 who underwent the exercise test, 37 (0.79%) had ischemic ECG change, and 155 (3.32%) had striking arrhythmia. These 228 subjects then did a treadmill exercise test with Bruce protocol. Twenty-two (0.47% of 4,703) showed positive ECG change, 9 (0.19%) of 22 had abnormal findings on a 201Tl scan. 8 (0.17%) were diagnosed as SMI (Cohn I), in which the prevalence of hypertension, hyperlipidemia, diabetes mellitus, smoker and positive familial history of ischemic heart disease was greater than that of all subjects. In a 15-30 month follow up, none has developed cardiac accidents. Exercise-induced arrhythmia was detected in 11 (0.23%) subjects. Four were non-sustained ventricular tachycardia without any organic disease, 4 were ventricular arrhythmia based on cardiomyopathy detected by echocardiography, 2 were atrial fibrillation and another was WPW syndrome. It is therefore likely that the ergometer exercise test in THP was effective in preventing sudden death caused by ischemic heart disease or striking arrhythmia.

  20. δ-Opioid receptor (DOR) signaling and reactive oxygen species (ROS) mediate intermittent hypoxia induced protection of canine myocardium.

    PubMed

    Estrada, Juan A; Williams, Arthur G; Sun, Jie; Gonzalez, Leticia; Downey, H Fred; Caffrey, James L; Mallet, Robert T

    2016-03-01

    Intermittent, normobaric hypoxia confers robust cardioprotection against ischemia-induced myocardial infarction and lethal ventricular arrhythmias. δ-Opioid receptor (DOR) signaling and reactive oxygen species (ROS) have been implicated in cardioprotective phenomena, but their roles in intermittent hypoxia are unknown. This study examined the contributions of DOR and ROS in mediating intermittent hypoxia-induced cardioprotection. Mongrel dogs completed a 20 day program consisting of 5-8 daily, 5-10 min cycles of moderate, normobaric hypoxia (FIO2 0.095-0.10), with intervening 4 min room air exposures. Subsets of dogs received the DOR antagonist naltrindole (200 μg/kg, sc) or antioxidant N-acetylcysteine (250 mg/kg, po) before each hypoxia session. Twenty-four hours after the last session, the left anterior descending coronary artery was occluded for 60 min and then reperfused for 5 h. Arrhythmias detected by electrocardiography were scored according to the Lambeth II conventions. Left ventricles were sectioned and stained with 2,3,5-triphenyl-tetrazolium-chloride, and infarct sizes were expressed as percentages of the area at risk (IS/AAR). Intermittent hypoxia sharply decreased IS/AAR from 41 ± 5 % (n = 12) to 1.8 ± 0.9 % (n = 9; P < 0.001) and arrhythmia score from 4.1 ± 0.3 to 0.7 ± 0.2 (P < 0.001) vs. non-hypoxic controls. Naltrindole (n = 6) abrogated the cardioprotection with IS/AAR 35 ± 5 % and arrhythmia score 3.7 ± 0.7 (P < 0.001 vs. untreated intermittent hypoxia). N-acetylcysteine (n = 6) interfered to a similar degree, with IS/AAR 42 ± 3 % and arrhythmia score 4.7 ± 0.3 (P < 0.001 vs. untreated intermittent hypoxia). Without the intervening reoxygenations, hypoxia (n = 4) was not cardioprotective (IS/AAR 50 ± 8 %; arrhythmia score 4.5 ± 0.5; P < 0.001 vs. intermittent hypoxia). Thus DOR, ROS and cyclic reoxygenation were obligatory participants in the gradually evolving cardioprotection produced by intermittent hypoxia.

  1. Is exposure to ionising radiation associated with childhood cardiac arrhythmia in the Russian territories contaminated by the Chernobyl fallout? A cross-sectional population-based study.

    PubMed

    Jourdain, Jean-Rene; Landon, Geraldine; Clero, Enora; Doroshchenko, Vladimir; Silenok, Aleksandr; Kurnosova, Irina; Butsenin, Andrei; Denjoy, Isabelle; Franck, Didier; Heuze, Jean-Pierre; Gourmelon, Patrick

    2018-03-25

    To investigate childhood cardiac arrhythmia and chronic exposure to caesium-137 ( 137 Cs) resulting from the Chernobyl accident. Prospective cross-sectional study using exposed/unexposed design conducted in the Bryansk region from May 2009 to May 2013 on children selected on the basis of 137 Cs soil deposition: control territories ([ 137 Cs]<37 kBq per square metre, where children were considered as unexposed) and contaminated territories ([ 137 Cs]>555 kBq per square metre, where children were considered as exposed). Russian territories affected by the Chernobyl fallout (Bryansk region). This cross-sectional study included 18 152 children aged 2-18 years and living in the Bryansk region (Russia). All children received three medical examinations (ECG, echocardiography and 137 Cs whole-body activity measurement) and some of them were given with a 24-hour Holter monitoring and blood tests. Cardiac arrhythmia was diagnosed in 1172 children living in contaminated territories and 1354 children living in control territories. The crude prevalence estimated to 13.3% in contaminated territories was significantly lower than in control territories with 15.2% over the period 2009-2013 (P<0.001). Considering 137 Cs whole-body burden as exposure, cardiac arrhythmia was found in 449 contaminated children and 2077 uncontaminated children, corresponding to an estimated crude prevalence of 14.5% and 14.2%, respectively, which does not differ significantly (P=0.74). Also, we investigated the association between territory, exposure to 137 Cs and cardiac arrhythmia: the adjusted OR was not significant (0.90 with 95% CI 0.81 to 1.00; P=0.06) for the territory. For 137 Cs whole-body burden, the ORs close to 1 did not reach statistical significance (P for trend=0.97). This study does not observe an association between cardiac arrhythmia and 137 Cs deposition levels in the Bryansk region exposed to Chernobyl fallout. The suspected increase of cardiac arrhythmia in children exposed to Chernobyl fallout is not confirmed. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  2. Risk of ventricular arrhythmias associated with nonsedating antihistamine drugs

    PubMed Central

    José de Abajo, Francisco; Rodríguez, Luis Alberto García

    1999-01-01

    Aims To quantify and compare the incidence of ventricular arrhythmias associated with the use of five nonsedating antihistamines: acrivastine, astemizole, cetirizine, loratadine and terfenadine. The effects of age, sex, dose, duration of treatment, and the interaction with P450 inhibitor drugs were also examined. Methods We carried out a cohort study with a nested case-control analysis using the UK-based General Practice Research Database (GPRD). The study cohort included persons aged less than 80 years old who received their first prescription for any of the five study drugs between January 1, 1992 and September 30, 1996. We estimated relative risks and 95% confidence intervals of idiopathic ventricular arrhythmias with current use of antihistamines as compared with non use. Results The study cohort included 197 425 persons who received 513 012 prescriptions. Over the study period 18 valid cases of idiopathic ventricular arrhythmias were detected. Nine occurred during the current use of any antihistamine, resulting in a crude incidence of 1.9 per 10 000 person-years (95%CI: 1.0–3.6) and a relative risk of 4.2 (95%CI: 1.5–11.8) as compared with non use. Astemizole presented the highest relative risk (RR = 19.0; 95%CI: 4.8–76.0) of all study drugs, while terfenadine (RR = 2.1; 95%CI:0.5–8.5) was in the range of other nonsedating antihistamines. Older age was associated with a greater risk of ventricular arrhythmias (RR = 7.4; 95%CI: 2.6–21.4) and seemed to increase the effect of antihistamines (RR = 6.4; 95%CI: 1.7–24.8). The proportions of high dose terfenadine and the concomitant use with P450 inhibitors among current users of terfenadine were 2.7% and 3.4%, respectively over the study period with no single case of ventricular arrhythmias occurring in the presence of these two risk factors. Conclusions The use of nonsedating antihistamines increases the risk of ventricular arrhythmias by a factor of four in the general population. Yet, the absolute effect is quite low requiring 57 000 prescriptions, or 5300 person-years of use for one case to occur. The risk associated with terfenadine was no different from that with other nonsedating antihistamines. PMID:10215756

  3. D-Sotalol: death by the SWORD or deserving of further consideration for clinical use?

    PubMed

    Doggrell, S A; Brown, L

    2000-07-01

    D-Sotalol is the dextro-rotatory isomer of sotalol and a class III anti-arrhythmic. D-Sotalol prolongs cardiac repolarisation by inhibiting the fast component of the delayed outward rectifying potassium channel. In animal studies, D-sotalol has been shown to be more effective in prolonging atrial, rather than ventricular, action potentials, suggesting that D-sotalol may be more effective against supra-ventricular than ventricular arrhythmias. Furthermore, in animal studies, D-sotalol induces after-depolarisations, which are predictors of pro-arrhythmic activity. D-Sotalol shows little or no reverse use dependence in animal and humans and has slow offset kinetics. This suggests that, in addition to being a preventative treatment for arrhythmias, D-sotalol may be effective at the start or during arrhythmia. As D-sotalol does not block the slow component of the delayed outward rectifying potassium channel, which is activated by the sympathetic nervous system, D-sotalol will not protect against sympathetic hyperactivity. D-Sotalol also has no effect on the K(ATP) channel, which is activated in ischaemia to shorten the action potential. Thus D-sotalol is less effective in ischaemia. Anti-arrhythmic activity with D-sotalol has been demonstrated in dog models of ventricular tachycardia and sudden death. Arrhythmias with D-sotalol have been demonstrated in an ischaemic guinea-pig ventricle model in the absence of action potentials. D-Sotalol is a weak beta-adrenoceptor antagonist and may also be a positive inotrope. In humans, D-sotalol has 100% systemic oral bioavailability, a terminal half-life of 7.2 h and is mainly excreted unchanged in the urine. Preliminary, mainly hospital-based, clinical trials showed that D-sotalol was effective in a variety of supraventricular and ventricular arrhythmias. However, a large clinical trial of D-sotalol as a preventative treatment for arrhythmias and sudden death after myocardial infarction, the SWORD trial, was terminated early because of increased mortality with D-sotalol. The group at greatest risk was those with a remote myocardial infarction and relatively good left ventricular function, the group that showed the lowest mortality when untreated. It is assumed that excessive prolongation of the action potential leading to pro-arrhythmia with D-sotalol, underlies the increased risk of death. However, there is little objective evidence in the SWORD trial to support this. Obviously D-sotalol should not be used in humans with a remote myocardial infarction and relatively good left ventricular function. D-Sotalol could still be considered for short-term hospital use in resistant arrhythmias and for longer-term use to prevent atrial fibrillation in those with remote myocardial infarction and poor left ventricular function.

  4. Writing Technical Reports for Simulation in Education for Health Professionals: Suggested Guidelines.

    PubMed

    Dubrowski, Adam; Alani, Sabrina; Bankovic, Tina; Crowe, Andrea; Pollard, Megan

    2015-11-02

    Simulation is an important training tool used in a variety of influential fields. However, development of simulation scenarios - the key component of simulation - occurs in isolation; sharing of scenarios is almost non-existent. This can make simulation use a costly task in terms of the resources and time and the possible redundancy of efforts. To alleviate these issues, the goal is to strive for an open communication of practice (CoP) surrounding simulation. To facilitate this goal, this report describes a set of guidelines for writing technical reports about simulation use for educating health professionals. Using an accepted set of guidelines will allow for homogeneity when building simulation scenarios and facilitate open sharing among simulation users. In addition to optimizing simulation efforts in institutions that are currently using simulation as an educational tool, the development of such a repository may have direct implications on developing countries, where simulation is only starting to be used systematically. Our project facilitates equivalent and global access to information, knowledge, and highest-caliber education - in this context, simulation - collectively, the building blocks of optimal healthcare.

  5. Writing Technical Reports for Simulation in Education for Health Professionals: Suggested Guidelines

    PubMed Central

    Alani, Sabrina; Bankovic, Tina; Crowe, Andrea; Pollard, Megan

    2015-01-01

    Simulation is an important training tool used in a variety of influential fields. However, development of simulation scenarios - the key component of simulation – occurs in isolation; sharing of scenarios is almost non-existent. This can make simulation use a costly task in terms of the resources and time and the possible redundancy of efforts. To alleviate these issues, the goal is to strive for an open communication of practice (CoP) surrounding simulation. To facilitate this goal, this report describes a set of guidelines for writing technical reports about simulation use for educating health professionals. Using an accepted set of guidelines will allow for homogeneity when building simulation scenarios and facilitate open sharing among simulation users. In addition to optimizing simulation efforts in institutions that are currently using simulation as an educational tool, the development of such a repository may have direct implications on developing countries, where simulation is only starting to be used systematically. Our project facilitates equivalent and global access to information, knowledge, and highest-caliber education - in this context, simulation – collectively, the building blocks of optimal healthcare.  PMID:26677421

  6. Feline arrhythmias: an update.

    PubMed

    Côté, Etienne

    2010-07-01

    In the cat, electrocardiography is indicated for assessing the rhythm of the heartbeat and identifying and monitoring the effect of certain systemic disorders on the heart. Basic information regarding feline electrocardiography is contained in several textbooks, and the reader is referred to these sources for background reading. This article describes selected clinical advances in feline cardiac arrhythmias and electrocardiography from the past decade.

  7. Cardiac Atrophy and Diastolic Dysfunction During and After Long Duration Spaceflight: Functional Consequences for Orthostatic Intolerance, Exercise Capability and Risk for Cardiac Arrhythmias

    NASA Technical Reports Server (NTRS)

    Levine, Benjamin D.; Bungo, Michael W.; Platts, Steven H.; Hamilton, Douglas R.; Johnston, Smith L.

    2009-01-01

    Cardiac Atrophy and Diastolic Dysfunction During and After Long Duration Spaceflight: Functional Consequences for Orthostatic Intolerance, Exercise Capability and Risk for Cardiac Arrhythmias (Integrated Cardiovascular) will quantify the extent of long-duration space flightassociated cardiac atrophy (deterioration) on the International Space Station crewmembers.

  8. The effects of B0, B20 and B100 soy biodiesel exhaust on aconitine-induced cardiac arrhythmia in spontaneously hypertensive rats

    EPA Science Inventory

    CONTEXT: Diesel exhaust (DE) has been shown to increase the risk of cardiac arrhythmias. Although biodiesel has been proposed as a "safer" alternative to diesel, it is still uncertain whether it actually poses less threat.OBJECTIVE: We hypothesized that exposure to pure or 20% so...

  9. Ventricular fibrillation in an ambulatory patient supported by a left ventricular assist device: highlighting the ICD controversy.

    PubMed

    Boilson, Barry A; Durham, Lucian A; Park, Soon J

    2012-01-01

    Left ventricular assist devices (LVADs) provide an effective means of managing advanced pump failure as a means of bridging to cardiac transplantation or as permanent therapy. Although ventricular arrhythmias remain common post-LVAD implantation, such therapy may allow malignant arrhythmias to be tolerated hemodynamically. This report describes the clinical findings in a patient who had likely been in a ventricular tachyarrhythmia for several days and presented in ventricular fibrillation, ambulatory, and mentating normally. This report, with previous similar reports, is additive to the body of evidence that LVADs alter the physiologic impact of ventricular arrhythmias in advanced heart failure and highlights the need for thoughtful programming of implantable cardioverter defibrillator therapies in these patients.

  10. ECG Signal Analysis and Arrhythmia Detection using Wavelet Transform

    NASA Astrophysics Data System (ADS)

    Kaur, Inderbir; Rajni, Rajni; Marwaha, Anupma

    2016-12-01

    Electrocardiogram (ECG) is used to record the electrical activity of the heart. The ECG signal being non-stationary in nature, makes the analysis and interpretation of the signal very difficult. Hence accurate analysis of ECG signal with a powerful tool like discrete wavelet transform (DWT) becomes imperative. In this paper, ECG signal is denoised to remove the artifacts and analyzed using Wavelet Transform to detect the QRS complex and arrhythmia. This work is implemented in MATLAB software for MIT/BIH Arrhythmia database and yields the sensitivity of 99.85 %, positive predictivity of 99.92 % and detection error rate of 0.221 % with wavelet transform. It is also inferred that DWT outperforms principle component analysis technique in detection of ECG signal.

  11. Cardiac Arrhythmias in Adults With Congenital Heart Disease: Scope, Specific Problems, and Management.

    PubMed

    Lindsay, Ian; Moore, Jeremy P

    2015-12-01

    Progressive advances in the field of congenital heart disease (CHD) have led to a dramatic rise in the number of affected patients surviving well into adulthood. Groundbreaking and innovative achievements in the medical, surgical, and interventional management of these patients have allowed them to lead full adult lives that have included raising families, completing degrees in higher education, and maintaining successful careers. As patients are living longer, arrhythmias have emerged as one of the most significant factors affecting their morbidity, mortality, and quality of life. This article aims to review the current understanding of arrhythmia within the adult congenital heart disease (ACHD) population, emphasizing recent advances and providing recommendations pertaining to the management of these patients.

  12. In Vivo Simulator for Microwave Treatment

    NASA Technical Reports Server (NTRS)

    Arndt, G. Dickey (Inventor); Carl, James R. (Inventor); Raffoul, George W. (Inventor); Karasack, Vincent G. (Inventor); Pacifico, Antonio (Inventor); Pieper, Carl F. (Inventor)

    2001-01-01

    Method and apparatus are provided for propagating microwave energy into heart tissues to produce a desired temperature profile therein at tissue depths sufficient for thermally ablating arrhythmogenic cardiac tissue to treat ventricular tachycardia and other arrhythmias while preventing excessive heating of surrounding tissues, organs, and blood. A wide bandwidth double-disk antenna is effective for this purpose over a bandwidth of about 6 GHz. A computer simulation provides initial screening capabilities for an antenna such as antenna. frequency, power level, and power application duration. The simulation also allows optimization of techniques for specific patients or conditions. In operation, microwave energy between about 1 GHz and 12 GHz is applied to monopole microwave radiator having a surface wave limiter. A test setup provides physical testing of microwave radiators to determine the temperature profile created in actual heart tissue or ersatz heart tissue. Saline solution pumped over the heart tissue with a peristaltic pump simulates blood flow. Optical temperature sensors disposed at various tissue depths within the heart tissue detect the temperature profile without creating any electromagnetic interference. The method may be used to produce a desired temperature profile in other body tissues reachable by catheter such as tumors and the like.

  13. A Systemic-Constructivist Approach to the Facilitation and Debriefing of Simulations and Games

    ERIC Educational Resources Information Center

    Kriz, Willy Christian

    2010-01-01

    This article introduces some basic concepts of a systemic-constructivist perspective. These show that gaming simulation corresponds closely to a systemic-constructivist approach to learning and instruction. Some quality aspects of facilitating and debriefing simulation games are described from a systemic-constructivist point of view. Finally, a…

  14. Challenging traditional activity limits after coronary artery bypass graft surgery: a simulated lawn-mowing activity.

    PubMed

    Adams, Jenny; Pullum, Gwen; Stafford, Pamala; Hanners, Nava; Hartman, Julie; Strauss, Danielle; Hubbard, Matt; Lawrence, Anne; Anderson, Valerie; McCullough, Tiffany

    2008-01-01

    Physician advice and restrictions to patients following a cardiac event can, in some instances, lead patients to be fearful regarding their activities even to the point of inactivity. The purpose of this study was to test whether lawn mowing, one of the activities most strongly discouraged after coronary artery bypass surgery, could be safely performed in a supervised setting. Subjects participated in a 6-session simulated lawn-mowing protocol, calibrated to match the push and pull forces of using an outdoor nonpropelled lawn mower. Plain chest radiographs were taken before and after the protocol period. During each session, subjects' sternums were carefully palpated and electrocardiograms, heart rates, and blood pressures were monitored. None of the 13 subjects experienced adverse arrhythmia events or detrimental heart rate, blood pressure, or sternal palpation findings that led to study discontinuation. The radiographs taken after protocol completion showed stable sternal wires with no evidence of sternal dehiscence. Simulated lawn mowing did not negatively affect the sternal incision, electrocardiogram findings, blood pressure, or heart rate in this small sample.

  15. In silico Analysis of Conformational Changes Induced by Mutation of Aromatic Binding Residues: Consequences for Drug Binding in the hERG K+ Channel

    PubMed Central

    Knape, Kirsten; Linder, Tobias; Wolschann, Peter; Beyer, Anton; Stary-Weinzinger, Anna

    2011-01-01

    Pharmacological inhibition of cardiac hERG K+ channels is associated with increased risk of lethal arrhythmias. Many drugs reduce hERG current by directly binding to the channel, thereby blocking ion conduction. Mutation of two aromatic residues (F656 and Y652) substantially decreases the potency of numerous structurally diverse compounds. Nevertheless, some drugs are only weakly affected by mutation Y652A. In this study we utilize molecular dynamics simulations and docking studies to analyze the different effects of mutation Y652A on a selected number of hERG blockers. MD simulations reveal conformational changes in the binding site induced by mutation Y652A. Loss of π-π-stacking between the two aromatic residues induces a conformational change of the F656 side chain from a cavity facing to cavity lining orientation. Docking studies and MD simulations qualitatively reproduce the diverse experimentally observed modulatory effects of mutation Y652A and provide a new structural interpretation for the sensitivity differences. PMID:22194911

  16. Electrophysiologic Study

    PubMed Central

    Gold, Daniel R.; Catanzaro, John N.; Makaryus, John N.; Waldman, Cory; Sauer, William H.; Sison, Cristina; Makaryus, Amgad N.; Altman, Erik; Jadonath, Ram; Beldner, Stuart

    2010-01-01

    Studies have shown the predictive value of inducible ventricular tachycardia and clinical arrhythmia in patients who have structural heart disease. We examined the possible predictive value of electrophysiologic study before the placement of an implantable cardioverter-defibrillator. Our retrospective study group comprised 315 patients who had ventricular tachycardia that was inducible during electrophysiologic study and who had undergone at least 1 month of follow-up (247 men; mean age, 66.9 ± 13.5 yr; mean follow-up, 24.9 ± 14.8 mo). Recorded characteristics included induced ventricular tachycardia cycle length, atrio-His and His-ventricular electrograms, PR and QT intervals, QRS duration, and drug therapy. Of the 315 patients, 97 experienced ventricular arrhythmia during the follow-up period, as registered by 184 of more than 400 interrogations. There were 187 episodes of ventricular arrhythmia (tachycardia, 178; fibrillation, 9) during 652.5 person-years of follow-up. Subjects with a cycle length ≥240 msec were more likely to have an earlier 1st arrhythmia than those with a cycle length <240 msec (P=0.032). A quarter of the subjects with a cycle length ≥240 msec had their 1st arrhythmia by 19.14 months, compared with 23.8 months for a quarter of the subjects with a cycle length <240 msec (P <0.032). Among the electrophysiologic characteristics examined, inducible ventricular tachycardia with a cycle length ≥240 msec is predictive of appropriate implantable cardioverter-defibrillator therapy at an earlier time. This may have prognostic implications that warrant implantable cardioverter-defibrillator programming to enable appropriate antitachycardia pacing in this group of patients. PMID:20548804

  17. Epicardial phrenic nerve displacement during catheter ablation of atrial and ventricular arrhythmias: procedural experience and outcomes.

    PubMed

    Kumar, Saurabh; Barbhaiya, Chirag R; Baldinger, Samuel H; Koplan, Bruce A; Maytin, Melanie; Epstein, Laurence M; John, Roy M; Michaud, Gregory F; Tedrow, Usha B; Stevenson, William G

    2015-08-01

    Arrhythmia origin in close proximity to the phrenic nerve (PN) can hinder successful catheter ablation. We describe our approach with epicardial PN displacement in such instances. PN displacement via percutaneous pericardial access was attempted in 13 patients (age 49±16 years, 9 females) with either atrial tachycardia (6 patients) or atrial fibrillation triggered from a superior vena cava focus (1 patient) adjacent to the right PN or epicardial ventricular tachycardia origin adjacent to the left PN (6 patients). An epicardially placed steerable sheath/4 mm-catheter combination (5 patients) or a vascular or an esophageal balloon (8 patients) was ultimately successful. Balloon placement was often difficult requiring manipulation via a steerable sheath. In 2 ventricular tachycardia cases, absence of PN capture was achieved only once the balloon was directly over the ablation catheter. In 3 atrial tachycardia patients, PN displacement was not possible with a balloon; however, a steerable sheath/catheter combination was ultimately successful. PN displacement allowed acute abolishment of all targeted arrhythmias. No PN injury occurred acutely or in follow up. Two patients developed acute complications (pleuro-pericardial fistula 1 and pericardial bleeding 1). Survival free of target arrhythmia was achieved in all atrial tachycardia patients; however, a nontargeted ventricular tachycardia recurred in 1 patient at a median of 13 months' follow up. Arrhythmias originating in close proximity to the PN can be targeted successfully with PN displacement with an epicardially placed steerable sheath/catheter combination, or balloon, but this strategy can be difficult to implement. Better tools for phrenic nerve protection are desirable. © 2015 American Heart Association, Inc.

  18. Abolition of reperfusion-induced arrhythmias in hearts from thiamine-deficient rats.

    PubMed

    Oliveira, Fernando A; Guatimosim, Silvia; Castro, Carlos H; Galan, Diogo T; Lauton-Santos, Sandra; Ribeiro, Angela M; Almeida, Alvair P; Cruz, Jader S

    2007-07-01

    Extensive work has been done regarding the impact of thiamine deprivation on the nervous system. In cardiac tissue, chronic thiamine deficiency is described to cause changes in the myocardium that can be associated with arrhythmias. However, compared with the brain, very little is known about the effects of thiamine deficiency on the heart. Thus this study was undertaken to explore whether thiamine deprivation has a role in cardiac arrhythmogenesis. We examined hearts isolated from thiamine-deprived and control rats. We measured heart rate, diastolic and systolic tension, and contraction and relaxation rates. Whole cell voltage clamp was performed in rat isolated cardiac myocytes to measure L-type Ca(2+) current. In addition, we investigated the global intracellular calcium transients by using confocal microscopy in the line-scan mode. The hearts from thiamine-deficient rats did not degenerate into ventricular fibrillation during 30 min of reperfusion after 15 min of coronary occlusion. The antiarrhythmogenic effects were characterized by the arrhythmia severity index. Our results suggest that hearts from thiamine-deficient rats did not experience irreversible arrhythmias. There was no change in L-type Ca(2+) current density. Inactivation kinetics of this current in Ca(2+)-buffered cells was retarded in thiamine-deficient cardiac myocytes. The global Ca(2+) release was significantly reduced in thiamine-deficient cardiac myocytes. The amplitude of caffeine-releasable Ca(2+) was lower in thiamine-deficient myocytes. In summary, we have found that thiamine deprivation attenuates the incidence and severity of postischemic arrhythmias, possibly through a mechanism involving a decrease in global Ca(2+) release.

  19. Remote Arrhythmia Monitoring System Developed

    NASA Technical Reports Server (NTRS)

    York, David W.; Mackin, Michael A.; Liszka, Kathy J.; Lichter, Michael J.

    2004-01-01

    Telemedicine is taking a step forward with the efforts of team members from the NASA Glenn Research Center, the MetroHealth campus of Case Western University, and the University of Akron. The Arrhythmia Monitoring System is a completed, working test bed developed at Glenn that collects real-time electrocardiogram (ECG) signals from a mobile or homebound patient, combines these signals with global positioning system (GPS) location data, and transmits them to a remote station for display and monitoring. Approximately 300,000 Americans die every year from sudden heart attacks, which are arrhythmia cases. However, not all patients identified at risk for arrhythmias can be monitored continuously because of technological and economical limitations. Such patients, who are at moderate risk of arrhythmias, would benefit from technology that would permit long-term continuous monitoring of electrical cardiac rhythms outside the hospital environment. Embedded Web Technology developed at Glenn to remotely command and collect data from embedded systems using Web technology is the catalyst for this new telemetry system (ref. 1). In the end-to-end system architecture, ECG signals are collected from a patient using an event recorder and are transmitted to a handheld personal digital assistant (PDA) using Bluetooth, a short-range wireless technology. The PDA concurrently tracks the patient's location via a connection to a GPS receiver. A long distance link is established via a standard Internet connection over a 2.5-generation Global System for Mobile Communications/General Packet Radio Service (GSM/GPRS)1 cellular, wireless infrastructure. Then, the digital signal is transmitted to a call center for monitoring by medical professionals.

  20. Connexin43 Gene Transfer Reduces Ventricular Tachycardia Susceptibility After Myocardial Infarction

    PubMed Central

    Greener, Ian D.; Sasano, Tetsuo; Wan, Xiaoping; Igarashi, Tomonori; Strom, Maria; Rosenbaum, David S.; Donahue, J. Kevin

    2012-01-01

    Objectives The aim of this study was to evaluate the links between connexin43 (Cx43) expression, myocardial conduction velocity, and ventricular tachycardia in a model of healed myocardial infarction. Background Post-infarction ventricular arrhythmias frequently cause sudden death. Impaired myocardial conduction has previously been linked to ventricular arrhythmias. Altered connexin expression is a potential source of conduction slowing identified in healed scar border tissues. The functional effect of increasing border-zone Cx43 has not been previously evaluated. Methods Twenty-five Yorkshire pigs underwent anterior infarction by transient left anterior descending coronary artery occlusion, followed by weekly testing for arrhythmia inducibility. Twenty animals with reproducibly inducible sustained monomorphic ventricular tachycardia were randomized 2:1:1 to receive AdCx43, Adβgal, or no gene transfer. One week later, animals underwent follow-up electrophysiologic study and tissue assessment for several functional and molecular measures. Results Animals receiving AdCx43 had less electrogram fractionation and faster conduction velocity in the anterior-septal border zone. Only 40% of AdCx43 animals remained inducible for ventricular tachycardia, while 100% of controls were inducible after gene transfer. AdCx43 animals had 2-fold higher Cx43 protein levels in the anterior-septal infarct border, with similar percents of phosphorylated and intercalated disk-localized Cx43 compared with controls. Conclusions These data mechanistically link Cx43 expression to slow conduction and arrhythmia susceptibility in the healed scar border zone. Targeted manipulation of Cx43 levels improved conduction velocity and reduced ventricular tachycardia susceptibility. Cx43 gene transfer represents a novel treatment strategy for post-infarction arrhythmias. PMID:22883636

  1. Carotid Body Ablation Abrogates Hypertension and Autonomic Alterations Induced by Intermittent Hypoxia in Rats.

    PubMed

    Del Rio, Rodrigo; Andrade, David C; Lucero, Claudia; Arias, Paulina; Iturriaga, Rodrigo

    2016-08-01

    Chronic intermittent hypoxia (CIH), the main feature of obstructive sleep apnea, enhances carotid body (CB) chemosensory responses to hypoxia and produces autonomic dysfunction, cardiac arrhythmias, and hypertension. We tested whether autonomic alterations, arrhythmogenesis, and the progression of hypertension induced by CIH depend on the enhanced CB chemosensory drive, by ablation of the CB chemoreceptors. Male Sprague-Dawley rats were exposed to control (Sham) conditions for 7 days and then to CIH (5% O2, 12/h 8 h/d) for a total of 28 days. At 21 days of CIH exposure, rats underwent bilateral CB ablation and then exposed to CIH for 7 additional days. Arterial blood pressure and ventilatory chemoreflex response to hypoxia were measured in conscious rats. In addition, cardiac autonomic imbalance, cardiac baroreflex gain, and arrhythmia score were assessed during the length of the experiments. In separate experimental series, we measured extracellular matrix remodeling content in cardiac atrial tissue and systemic oxidative stress. CIH induced hypertension, enhanced ventilatory response to hypoxia, induced autonomic imbalance toward sympathetic preponderance, reduced baroreflex gain, and increased arrhythmias and atrial fibrosis. CB ablation normalized blood pressure, reduced ventilatory response to hypoxia, and restored cardiac autonomic and baroreflex function. In addition, CB ablation reduced the number of arrhythmias, but not extracellular matrix remodeling or systemic oxidative stress, suggesting that reductions in arrhythmia incidence during CIH were related to normalization of cardiac autonomic balance. Present results show that autonomic alterations induced by CIH are critically dependent on the CB and support a main role for the CB in the CIH-induced hypertension. © 2016 American Heart Association, Inc.

  2. Risk of and risk factors for hypoglycemia and associated arrhythmias in patients with type 2 diabetes and cardiovascular disease: a cohort study under real-world conditions.

    PubMed

    Pistrosch, Frank; Ganz, Xenia; Bornstein, Stefan R; Birkenfeld, Andreas L; Henkel, Elena; Hanefeld, Markolf

    2015-10-01

    Severe hypoglycemia is one of the strongest predictors of adverse clinical outcomes in patients with type 2 diabetes. Our study addressed the question whether there is a relationship between hypoglycemic events (HE) and severe cardiac arrhythmias in type 2 diabetic patients with established clinical risk factors under real-world conditions. We included 94 patients with type 2 diabetes and documented cardiovascular disease, in which interstitial glucose values and Holter ECG were recorded for 5 days in parallel. Patients received a stable treatment with insulin and/or sulfonylurea and were instructed to record symptoms of hypoglycemia or arrhythmias. Continuous glucose monitoring revealed 54 HE (interstitial glucose <3.1 mmol/l) in a total of 26 patients. Patients perceived only 39 % of HE during the day and 11 % of HE during the night. Patients with HE had a significantly higher number of severe ventricular arrhythmias [ventricular tachycardia (VT) 32.8 ± 60 vs. 0.9 ± 4.2, p = 0.019], and multivariate regression analysis revealed the duration of severe HE and TSH level as independent predictors of the occurrence of a VT. In conclusion, our study suggests that hypoglycemia might be able to trigger at least under certain circumstances, such as low TSH, ventricular arrhythmias under real-world conditions. The large number of unrecognized HE and VT in vulnerable patients treated with insulin or sulfonylurea should encourage the practitioner to focus on stable glucose control and to search for silent HE.

  3. Partial IK1 blockade destabilizes spiral wave rotation center without inducing wave breakup and facilitates termination of reentrant arrhythmias in ventricles.

    PubMed

    Kushiyama, Yasunori; Honjo, Haruo; Niwa, Ryoko; Takanari, Hiroki; Yamazaki, Masatoshi; Takemoto, Yoshio; Sakuma, Ichiro; Kodama, Itsuo; Kamiya, Kaichiro

    2016-09-01

    It has been reported that blockade of the inward rectifier K(+) current (IK1) facilitates termination of ventricular fibrillation. We hypothesized that partial IK1 blockade destabilizes spiral wave (SW) re-entry, leading to its termination. Optical action potential (AP) signals were recorded from left ventricles of Langendorff-perfused rabbit hearts with endocardial cryoablation. The dynamics of SW re-entry were analyzed during ventricular tachycardia (VT), induced by cross-field stimulation. Intercellular electrical coupling in the myocardial tissue was evaluated by the space constant. In separate experiments, AP recordings were made using the microelectrode technique from right ventricular papillary muscles of rabbit hearts. Ba(2+) (10-50 μM) caused a dose-dependent prolongation of VT cycle length and facilitated termination of VT in perfused hearts. Baseline VT was maintained by a stable rotor, where an SW rotated around an I-shaped functional block line (FBL). Ba(2+) at 10 μM prolonged I-shaped FBL and phase-singularity trajectory, whereas Ba(2+) at 50 μM transformed the SW rotation dynamics from a stable linear pattern to unstable circular/cycloidal meandering. The SW destabilization was not accompanied by SW breakup. Under constant pacing, Ba(2+) caused a dose-dependent prolongation of APs, and Ba(2+) at 50 μM decreased conduction velocity. In papillary muscles, Ba(2+) at 50 μM depolarized the resting membrane potential. The space constant was increased by 50 μM Ba(2+) Partial IK1 blockade destabilizes SW rotation dynamics through a combination of prolongation of the wave length, reduction of excitability, and enhancement of electrotonic interactions, which facilitates termination of ventricular tachyarrhythmias. Copyright © 2016 the American Physiological Society.

  4. Atrial fibrillation and sudden cardiac death: catheter-based sensor and mapping system of the heart

    NASA Astrophysics Data System (ADS)

    Ramasamy, Mouli; Kumar, Prashanth S.; Varadan, Vijay K.

    2017-04-01

    Ventricular arrhythmias in the heart and the rapid heartbeat of ventricular tachycardia can lead to sudden cardiac death. This is a major health issue worldwide. What is needed is to develop a catheter based sensor and mapping approach which will provide the mechanisms of ventricular arrhythmia, and effectively prevent and treat the same, potentially save life.

  5. Differential Susceptibility and the Early Development of Aggression: Interactive Effects of Respiratory Sinus Arrhythmia and Environmental Quality

    ERIC Educational Resources Information Center

    Eisenberg, Nancy; Sulik, Michael J.; Spinrad, Tracy L.; Edwards, Alison; Eggum, Natalie D.; Liew, Jeffrey; Sallquist, Julie; Popp, Tierney K.; Smith, Cynthia L.; Hart, Daniel

    2012-01-01

    The purpose of the current study was to predict the development of aggressive behavior from young children's respiratory sinus arrhythmia (RSA) and environmental quality. In a longitudinal sample of 213 children, baseline RSA, RSA suppression in response to a film of crying babies, and a composite measure of environmental quality (incorporating…

  6. Postmortem ICD interrogation in mode of death classification.

    PubMed

    Nikolaidou, Theodora; Johnson, Miriam J; Ghosh, Justin M; Marincowitz, Carl; Shah, Saumil; Lammiman, Michael J; Schilling, Richard J; Clark, Andrew L

    2018-04-01

    The definition of sudden death due to arrhythmia relies on the time interval between onset of symptoms and death. However, not all sudden deaths are due to arrhythmia. In patients with an implantable cardioverter defibrillator (ICD), postmortem device interrogation may help better distinguish the mode of death compared to a time-based definition alone. This study aims to assess the proportion of "sudden" cardiac deaths in patients with an ICD that have confirmed arrhythmia. We conducted a literature search for studies using postmortem ICD interrogation and a time-based classification of the mode of death. A modified QUADAS-2 checklist was used to assess risk of bias in individual studies. Outcome data were pooled where sufficient data were available. Our search identified 22 studies undertaken between 1982 and 2015 with 23,600 participants. The pooled results (excluding studies with high risk of bias) suggest that ventricular arrhythmias are present at the time of death in 76% of "sudden" deaths (95% confidence interval [CI] 67-85; range 42-88). Postmortem ICD interrogation identifies 24% of "sudden" deaths to be nonarrhythmic. Postmortem device interrogation should be considered in all cases of unexplained sudden cardiac death. © 2018 Wiley Periodicals, Inc.

  7. Genetic testing in heritable cardiac arrhythmia syndromes: differentiating pathogenic mutations from background genetic noise.

    PubMed

    Giudicessi, John R; Ackerman, Michael J

    2013-01-01

    In this review, we summarize the basic principles governing rare variant interpretation in the heritable cardiac arrhythmia syndromes, focusing on recent advances that have led to disease-specific approaches to the interpretation of positive genetic testing results. Elucidation of the genetic substrates underlying heritable cardiac arrhythmia syndromes has unearthed new arrhythmogenic mechanisms and given rise to a number of clinically meaningful genotype-phenotype correlations. As such, genetic testing for these disorders now carries important diagnostic, prognostic, and therapeutic implications. Recent large-scale systematic studies designed to explore the background genetic 'noise' rate associated with these genetic tests have provided important insights and enhanced how positive genetic testing results are interpreted for these potentially lethal, yet highly treatable, cardiovascular disorders. Clinically available genetic tests for heritable cardiac arrhythmia syndromes allow the identification of potentially at-risk family members and contribute to the risk-stratification and selection of therapeutic interventions in affected individuals. The systematic evaluation of the 'signal-to-noise' ratio associated with these genetic tests has proven critical and essential to assessing the probability that a given variant represents a rare pathogenic mutation or an equally rare, yet innocuous, genetic bystander.

  8. Temporal abstraction and inductive logic programming for arrhythmia recognition from electrocardiograms.

    PubMed

    Carrault, G; Cordier, M-O; Quiniou, R; Wang, F

    2003-07-01

    This paper proposes a novel approach to cardiac arrhythmia recognition from electrocardiograms (ECGs). ECGs record the electrical activity of the heart and are used to diagnose many heart disorders. The numerical ECG is first temporally abstracted into series of time-stamped events. Temporal abstraction makes use of artificial neural networks to extract interesting waves and their features from the input signals. A temporal reasoner called a chronicle recogniser processes such series in order to discover temporal patterns called chronicles which can be related to cardiac arrhythmias. Generally, it is difficult to elicit an accurate set of chronicles from a doctor. Thus, we propose to learn automatically from symbolic ECG examples the chronicles discriminating the arrhythmias belonging to some specific subset. Since temporal relationships are of major importance, inductive logic programming (ILP) is the tool of choice as it enables first-order relational learning. The approach has been evaluated on real ECGs taken from the MIT-BIH database. The performance of the different modules as well as the efficiency of the whole system is presented. The results are rather good and demonstrate that integrating numerical techniques for low level perception and symbolic techniques for high level classification is very valuable.

  9. Keeping a Beat on the Heart

    NASA Technical Reports Server (NTRS)

    Liszka, Kathy J.; Mackin, Michael A.; Liehter, Michael J.; York, David W.; Pillai, Dilip; Rosenbaum, David S.

    2005-01-01

    Feel the relief of a patient suffering from heart arrhythmia, who is able to return home while having her heart monitored by health professionals 24 hours a day, without the fear that she will miss an important indicator and suffer a fatal heart attack - using technology originally developed to conduct experiments on the Space Shuttle. Approximately 400,000 Americans die every year from sudden heart attacks . Medical research revealed that patterns of electrical activity in the heart can act as predictors of these lethal cardiac events known as arrhythmias. Fortunately, certain arrhythmias such as ventricular fibrillation (loss of regular heartbeat and subsequent loss of function) and ventricular tachycardia (rapid heartbeats), can be detected and appropriately treated. Today, patients at moderate risk of arrhythmias can benefit from technology that would permit long- term continuous monitoring of electrical cardiac rhythms outside the hospital environment in the comfort of their own homes. Medical telemetry systems, also known as telemedicine, are evolving rapidly as wireless communication technology advances, evidenced by the commercial products and research prototypes for remote health monitoring that have appeared in recent years. Wireless systems allow patients to move freely in their home and work environment while being monitored remotely by health care professionals.

  10. [Heart disease in sports horses: Current recommendations of the 2014 ACVIM / ECEIM consensus statement].

    PubMed

    Schwarzwald, C

    2016-10-01

    Heart murmurs and arrhythmias are common in horses. Assessment of their clinical relevance concerning health, performance, safety and longevity of sports horses is of highest importance. A comprehensive cardiovascular examination is crucial for diagnosis and assessment of the severity of disease. Recently, an expert panel of the American College of Veterinary Internal Medicine (ACVIM) and the European College of Equine Internal Medicine (ECEIM) developed a consensus statement containing recommendations for sports horses with heart disease. This article summarizes the most relevant recommendations for practitioners, considering the most common and most important cardiac disorders in adult sports horses. These include mitral, aortic and tricuspid insufficiency, ventricular septal defects, atrial fibrillation as well as supraventricular and ventricular arrhythmias. Despite the fact that most horses with cardiovascular disease maintain a sufficient performance capacity, regular evaluations are indicated in horses with clinically relevant disorders. Under certain circumstances, horses with moderate to severe structural disease, with persistent untreated atrial fibrillation and with certain ventricular arrhythmias might still be used by informed adult riders. Horses with complex ventricular arrhythmias, pulmonary hypertension or congestive heart failure must not be ridden or driven and should be retired.

  11. Influence of energy drinks and alcohol on post-exercise heart rate recovery and heart rate variability.

    PubMed

    Wiklund, Urban; Karlsson, Marcus; Oström, Mats; Messner, Torbjörn

    2009-01-01

    Media have anecdotally reported that drinking energy drinks in combination with alcohol and exercise could cause sudden cardiac death. This study investigated changes in the electrocardiogram (ECG) and heart rate variability after intake of an energy drink, taken in combination with alcohol and exercise. Ten healthy volunteers (five men and five women aged 19-30) performed maximal bicycle ergometer exercise for 30 min after: (i) intake of 0.75 l of an energy drink mixed with alcohol; (ii) intake of energy drink; and, (iii) no intake of any drink. ECG was continuously recorded for analysis of heart rate variability and heart rate recovery. No subject developed any clinically significant arrhythmias. Post-exercise recovery in heart rate and heart rate variability was slower after the subjects consumed energy drink and alcohol before exercise, than after exercise alone. The healthy subjects developed blunted cardiac autonomic modulation after exercising when they had consumed energy drinks mixed with alcohol. Although they did not develop any significant arrhythmia, individuals predisposed to arrhythmia by congenital or other rhythm disorders could have an increased risk for malignant cardiac arrhythmia in similar situations.

  12. Nonlinear and Stochastic Dynamics in the Heart

    PubMed Central

    Qu, Zhilin; Hu, Gang; Garfinkel, Alan; Weiss, James N.

    2014-01-01

    In a normal human life span, the heart beats about 2 to 3 billion times. Under diseased conditions, a heart may lose its normal rhythm and degenerate suddenly into much faster and irregular rhythms, called arrhythmias, which may lead to sudden death. The transition from a normal rhythm to an arrhythmia is a transition from regular electrical wave conduction to irregular or turbulent wave conduction in the heart, and thus this medical problem is also a problem of physics and mathematics. In the last century, clinical, experimental, and theoretical studies have shown that dynamical theories play fundamental roles in understanding the mechanisms of the genesis of the normal heart rhythm as well as lethal arrhythmias. In this article, we summarize in detail the nonlinear and stochastic dynamics occurring in the heart and their links to normal cardiac functions and arrhythmias, providing a holistic view through integrating dynamics from the molecular (microscopic) scale, to the organelle (mesoscopic) scale, to the cellular, tissue, and organ (macroscopic) scales. We discuss what existing problems and challenges are waiting to be solved and how multi-scale mathematical modeling and nonlinear dynamics may be helpful for solving these problems. PMID:25267872

  13. Computational approaches to understand cardiac electrophysiology and arrhythmias

    PubMed Central

    Roberts, Byron N.; Yang, Pei-Chi; Behrens, Steven B.; Moreno, Jonathan D.

    2012-01-01

    Cardiac rhythms arise from electrical activity generated by precisely timed opening and closing of ion channels in individual cardiac myocytes. These impulses spread throughout the cardiac muscle to manifest as electrical waves in the whole heart. Regularity of electrical waves is critically important since they signal the heart muscle to contract, driving the primary function of the heart to act as a pump and deliver blood to the brain and vital organs. When electrical activity goes awry during a cardiac arrhythmia, the pump does not function, the brain does not receive oxygenated blood, and death ensues. For more than 50 years, mathematically based models of cardiac electrical activity have been used to improve understanding of basic mechanisms of normal and abnormal cardiac electrical function. Computer-based modeling approaches to understand cardiac activity are uniquely helpful because they allow for distillation of complex emergent behaviors into the key contributing components underlying them. Here we review the latest advances and novel concepts in the field as they relate to understanding the complex interplay between electrical, mechanical, structural, and genetic mechanisms during arrhythmia development at the level of ion channels, cells, and tissues. We also discuss the latest computational approaches to guiding arrhythmia therapy. PMID:22886409

  14. Heart Rate Variability Moderates the Association Between Separation-Related Psychological Distress and Blood Pressure Reactivity Over Time.

    PubMed

    Bourassa, Kyle J; Hasselmo, Karen; Sbarra, David A

    2016-08-01

    Divorce is a stressor associated with long-term health risk, though the mechanisms of this effect are poorly understood. Cardiovascular reactivity is one biological pathway implicated as a predictor of poor long-term health after divorce. A sample of recently separated and divorced adults (N = 138) was assessed over an average of 7.5 months to explore whether individual differences in heart rate variability-assessed by respiratory sinus arrhythmia-operate in combination with subjective reports of separation-related distress to predict prospective changes in cardiovascular reactivity, as indexed by blood pressure reactivity. Participants with low resting respiratory sinus arrhythmia at baseline showed no association between divorce-related distress and later blood pressure reactivity, whereas participants with high respiratory sinus arrhythmia showed a positive association. In addition, within-person variation in respiratory sinus arrhythmia and between-persons variation in separation-related distress interacted to predict blood pressure reactivity at each laboratory visit. Individual differences in heart rate variability and subjective distress operate together to predict cardiovascular reactivity and may explain some of the long-term health risk associated with divorce. © The Author(s) 2016.

  15. Postoperative administration of landiolol hydrochloride for patients with supraventricular arrhythmia: the efficacy of sustained intravenous infusion at a low dose.

    PubMed

    Wariishi, Seiichiro; Yamashita, Koichi; Nishimori, Hideaki; Fukutomi, Takashi; Yamamoto, Masaki; Radhakrishnan, Geethalakshmi; Sasaguri, Shiro

    2009-11-01

    The purpose of this study was to investigate the efficacy of landiolol hydrochloride, a short-acting beta(1) blocker, by initiating its administration at a low dose (5 microg kg(-1) min(-1)) in patients with postoperative supraventricular arrhythmia. The efficacy of landiolol was evaluated in 38 patients who, after developing postoperative atrial flutter or fibrillation, with sinus tachycardia and two patients who had a history of paroxysmal atrial fibrillation with frequent atrial extrasystole. The heart rate and blood pressure before and 2 h after the administration of landiolol were compared. A return to the sinus rhythm from supraventricular arrhythmia was noted in 89%. The heart rate was reduced from 137+/-26 bpm (before landiolol administration) to 93+/-18 bpm (2 h after the start of the medication, P<0.01). As an agent to correct an arrhythmic condition, landiolol successfully raised the systolic blood pressure from 108+/-24 mmHg (before medication) to 120+/-19 mmHg (2 h after the medication was started, P<0.05). Continuous intravenous infusion of landiolol at a low dose was found to be effective for postoperative supraventricular arrhythmia.

  16. Ablation of atrial fibrillation with concomitant cardiac surgery.

    PubMed

    Gillinov, A Marc; Saltman, Adam E

    2007-01-01

    Atrial fibrillation is present in approximately 35% of patients presenting for mitral valve surgery and in 1 to 6% of adult patients undergoing other forms of cardiac surgery. If left untreated, atrial fibrillation is associated with increased morbidity, and, in some subgroups, increased mortality. Therefore, concomitant management of the arrhythmia is indicated in most cardiac surgery patients with preexisting atrial fibrillation. Although the cut-and-sew Cox-maze III procedure is extremely effective, it has been supplanted by newer operations that rely on alternate energy sources to create lines of conduction block. Early and mid-term results are good with a variety of technologies. Choice of lesion set remains a matter of debate, but results of ablation appear to be enhanced by a biatrial lesion set. Targeted areas for improvement in concomitant ablation include acceptance of uniform standards for reporting results, development of improved technology for ablation and intraoperative assessment, and creation of instrumentation that facilitates minimally invasive approaches.

  17. An interdisciplinary approach to personalized medicine: case studies from a cardiogenetics clinic.

    PubMed

    Erskine, Kathleen E; Griffith, Eleanor; Degroat, Nicole; Stolerman, Marina; Silverstein, Louise B; Hidayatallah, Nadia; Wasserman, David; Paljevic, Esma; Cohen, Lilian; Walsh, Christine A; McDonald, Thomas; Marion, Robert W; Dolan, Siobhan M

    2013-01-01

    In the genomic age, the challenges presented by various inherited conditions present a compelling argument for an interdisciplinary model of care. Cardiac arrhythmias with a genetic basis, such as long QT syndrome, require clinicians with expertise in many specialties to address the complex genetic, psychological, ethical and medical issues involved in treatment. The Montefiore-Einstein Center for CardioGenetics has been established to provide personalized, interdisciplinary care for families with a history of sudden cardiac death or an acute cardiac event. Four vignettes of patient care are presented to illustrate the unique capacity of an interdisciplinary model to address genetic, psychological, ethical and medical issues. Because interdisciplinary clinics facilitate collaboration among multiple specialties, they allow for individualized, comprehensive care to be delivered to families who experience complex inherited medical conditions. As the genetic basis of many complex conditions is discovered, the advantages of an interdisciplinary approach for delivering personalized medicine will become more evident.

  18. Early detection of myocardial infarction following blunt chest trauma by computed tomography: a case report.

    PubMed

    Lee, Thung-Lip; Hsuan, Chin-Feng; Shih, Chen-Hsiang; Liang, Huai-Wen; Tsai, Hsing-Shan; Tseng, Wei-Kung; Hsu, Kwan-Lih

    2017-02-10

    Blunt cardiac trauma encompasses a wide range of clinical entities, including myocardial contusion, cardiac rupture, valve avulsion, pericardial injuries, arrhythmia, and even myocardial infarction. Acute myocardial infarction due to coronary artery dissection after blunt chest trauma is rare and may be life threatening. Differential diagnosis of acute myocardial infarction from cardiac contusion at this setting is not easy. Here we demonstrated a case of blunt chest trauma, with computed tomography detected myocardium enhancement defect early at emergency department. Under the impression of acute myocardial infarction, emergent coronary angiography revealed left anterior descending artery occlusion. Revascularization was performed and coronary artery dissection was found after thrombus aspiration. Finally, the patient survived after coronary stenting. Perfusion defects of myocardium enhancement on CT after blunt chest trauma can be very helpful to suggest myocardial infarction and facilitate the decision making of emergent procedure. This valuable sign should not be missed during the initial interpretation.

  19. Subclinical hyperthyroidism: current concepts and scintigraphic imaging.

    PubMed

    Intenzo, Charles; Jabbour, Serge; Miller, Jeffrey L; Ahmed, Intekhab; Furlong, Kevin; Kushen, Medina; Kim, Sung M; Capuzzi, David M

    2011-09-01

    Subclinical hyperthyroidism is defined as normal serum free thyroxine and a free triiodothyronine level, with a thyroid-stimulating hormone level suppressed below the normal range and is usually undetectable. Although patients with this diagnosis have no or few signs and symptoms of overt thyrotoxicosis, there is sufficient evidence that it is associated with a relatively higher risk of supraventricular arrhythmias as well as the acceleration or the development of osteoporosis. Consequently, the approach to the patient with subclinical hyperthyroidism is controversial, that is, therapeutic intervention versus watchful waiting. Regardless, it is imperative for the referring physician to identify the causative thyroid disorder. This is optimally accomplished by a functional study, namely scintigraphy. Recognition of the scan findings of the various causes of subclinical hyperthyroidism enables the imaging specialist to help in diagnosing the underlying condition causing thyroid-stimulating hormone suppression thereby facilitating the workup and management of this thyroid disorder.

  20. [Clinical aspects and prognostic factors of icterohemorrhagic leptospirosis in adults. Apropos of 249 cases in La Reunion].

    PubMed

    Pertuiset, E; Fen Chong, M; Duval, G; Génin, R

    1988-01-01

    Human leptospirosis of the classical and severe icterohemorrhagic type, usually due to the L. icterohaemorrhagiae serogroup, is frequent in La Réunion. In a retrospective study conducted between 1980 and 1984 in 249 adult patients, the mortality rate was 13 p. 100. Our data and those found in the literature indicate that the main cause of death is pneumopathy, followed by profuse haemorrhages, arrhythmias and cardiovascular collapse. Acute renal failure is common and often severe; it facilitates gastrointestinal bleeding and is of poor prognosis, particularly in patients with prolonged anuria, a possible cause of lethal hyperkalaemia. Other factors of unfavourable outcome have been demonstrated statistically; they include disturbances of consciousness, hypoprothrombinaemia, epigastric muscle rigidity, hyperleukocytosis, thrombocytopenia, high aspartate aminotransferase levels and chronic alcoholism. At the moment, pulmonary, cardiac and haemorrhagic complications concur with renal failure to darken the prognosis of these severe forms of leptospirosis.

  1. A Tutorial on RxODE: Simulating Differential Equation Pharmacometric Models in R.

    PubMed

    Wang, W; Hallow, K M; James, D A

    2016-01-01

    This tutorial presents the application of an R package, RxODE, that facilitates quick, efficient simulations of ordinary differential equation models completely within R. Its application is illustrated through simulation of design decision effects on an adaptive dosing regimen. The package provides an efficient, versatile way to specify dosing scenarios and to perform simulation with variability with minimal custom coding. Models can be directly translated to Rshiny applications to facilitate interactive, real-time evaluation/iteration on simulation scenarios.

  2. Initiation of rotors by fast propagation regions in excitable media: A theoretical study

    NASA Astrophysics Data System (ADS)

    Gao, Xiang; Krekhov, Alexei; Zykov, Vladimir; Bodenschatz, Eberhard

    2018-02-01

    We study the effect of geometry of a fast propagation region (FPR) in an excitable medium on the rotor initiation using a generic two-dimensional reaction-diffusion model. We find that, while the flat boundary of a rectangularly shaped FPR may block the propagation of the excitation wave, a large local curvature at the rounded corners of the FPR would prevent the blockage and thus initiate a rotor. Our simulations demonstrate that the prerequisites for the rotor initiation are the degree of the heterogeneity, its shape and size. These results may explain the incidence of arrhythmias by local heterogeneities induced, for example, by a cardiac tissue remodeling.

  3. Controlling three-dimensional vortices using multiple and moving external fields

    NASA Astrophysics Data System (ADS)

    Das, Nirmali Prabha; Dutta, Sumana

    2017-08-01

    Spirals or scroll wave activities in cardiac tissues are the cause of lethal arrhythmias. The external control of these waves is thus of prime interest to scientists and physicians. In this article, we demonstrate the spatial control of scroll waves by using external electric fields and thermal gradients in experiments with the Belousov-Zhabotinsky reaction. We show that a scroll ring can be made to trace cyclic trajectories under a rotating electric field. Application of a thermal gradient in addition to the electric field deflects the motion and changes the nature of the trajectory. Our experimental results are analyzed and corroborated by numerical simulations based on an excitable reaction diffusion model.

  4. Mitral valve prolapse and electrolyte abnormality: a dangerous combination for ventricular arrhythmias

    PubMed Central

    Rajani, Ali Raza; Murugesan, Vagishwari; Baslaib, Fahad Omar; Rafiq, Muhammad Anwer

    2014-01-01

    A 27-year-old woman with a history of bileaflet mitral valve prolapse and moderate mitral regurgitation presented to our emergency with untractable polymorphic wide complex tachycardia and unstable haemodynamics. After cardiopulmonary resuscitation, return of spontaneous circulation was achieved 30 min later. Her post-resuscitation ECG showed a prolonged QT interval which progressively normalised over the same day. Her laboratory investigations revealed hypocalcaemia while other electrolytes were within normal limits. A diagnosis of ventricular arrhythmia secondary to structural heart disease further precipitated by hypocalcaemia was made. Further hospital stay did not reveal a recurrence of prolonged QT interval or other arrhythmias except for an episode of non-sustained ventricular tachycardia. However, the patient suffered diffuse hypoxic brain encephalopathy secondary to prolonged cardiopulmonary resuscitation. PMID:24827670

  5. [Development of a portable ambulatory ECG monitor based on embedded microprocessor unit].

    PubMed

    Wang, Da-xiong; Wang, Guo-jun

    2005-06-01

    To develop a new kind of portable ambulatory ECG monitor. The hardware and software were designed based on RCA-CDP1802. New methods of ECG data compression and feature extraction of QRS complexes were applied to software design. A model for automatic arrhythmia analysis was established for real-time ambulatory ECG Data analysis. Compact, low power consumption and low cost were emphasized in the hardware design. This compact and light-weight monitor with low power consumption and high intelligence was capable of real-time monitoring arrhythmia for more than 48 h. More than ten types of arrhythmia could be detected, only the compressed abnormal ECG data was recorded and could be transmitted to the host if required. The monitor meets the design requirements and can be used for ambulatory ECG monitoring.

  6. [Arrhythmias and heart blocks in flying personnel with mitral valve prolapses].

    PubMed

    Zakharov, V P; Karlov, V N; Bondareva, S V; Vlasov, V D

    1999-01-01

    Investigated were 76 pilots with ECG-verified mitral valve prolapses (MVP) of the 1st and 2nd degree (w/o profound regurgitation). There were various heart blocks and ECG repolarization changes in 35 cases. Comparison of results of the cardiovascular functional investigations of flyers with MVP displayed non-specific cardiac rhythm and conductance disturbances that were registered more often during ECG-monitoring or test loading. According to the data of this study, bicycle and treadmill ergometry revealed "pseudoischemic" shifts in ECG. Literary indications of a significant loss in human endurance of physical loads due to MVP combined with the strain-induced arrhythmia received the experimental confirmation. Probably, arrhythmias in flyers with diagnosed MVP are predominantly associated with electric instability of the myocardium against the autonomous dysfunction with prevailing adrenergic effects.

  7. Methods for Computationally Efficient Structured CFD Simulations of Complex Turbomachinery Flows

    NASA Technical Reports Server (NTRS)

    Herrick, Gregory P.; Chen, Jen-Ping

    2012-01-01

    This research presents more efficient computational methods by which to perform multi-block structured Computational Fluid Dynamics (CFD) simulations of turbomachinery, thus facilitating higher-fidelity solutions of complicated geometries and their associated flows. This computational framework offers flexibility in allocating resources to balance process count and wall-clock computation time, while facilitating research interests of simulating axial compressor stall inception with more complete gridding of the flow passages and rotor tip clearance regions than is typically practiced with structured codes. The paradigm presented herein facilitates CFD simulation of previously impractical geometries and flows. These methods are validated and demonstrate improved computational efficiency when applied to complicated geometries and flows.

  8. Association of Arrhythmia-Related Genetic Variants With Phenotypes Documented in Electronic Medical Records.

    PubMed

    Van Driest, Sara L; Wells, Quinn S; Stallings, Sarah; Bush, William S; Gordon, Adam; Nickerson, Deborah A; Kim, Jerry H; Crosslin, David R; Jarvik, Gail P; Carrell, David S; Ralston, James D; Larson, Eric B; Bielinski, Suzette J; Olson, Janet E; Ye, Zi; Kullo, Iftikhar J; Abul-Husn, Noura S; Scott, Stuart A; Bottinger, Erwin; Almoguera, Berta; Connolly, John; Chiavacci, Rosetta; Hakonarson, Hakon; Rasmussen-Torvik, Laura J; Pan, Vivian; Persell, Stephen D; Smith, Maureen; Chisholm, Rex L; Kitchner, Terrie E; He, Max M; Brilliant, Murray H; Wallace, John R; Doheny, Kimberly F; Shoemaker, M Benjamin; Li, Rongling; Manolio, Teri A; Callis, Thomas E; Macaya, Daniela; Williams, Marc S; Carey, David; Kapplinger, Jamie D; Ackerman, Michael J; Ritchie, Marylyn D; Denny, Joshua C; Roden, Dan M

    2016-01-05

    Large-scale DNA sequencing identifies incidental rare variants in established Mendelian disease genes, but the frequency of related clinical phenotypes in unselected patient populations is not well established. Phenotype data from electronic medical records (EMRs) may provide a resource to assess the clinical relevance of rare variants. To determine the clinical phenotypes from EMRs for individuals with variants designated as pathogenic by expert review in arrhythmia susceptibility genes. This prospective cohort study included 2022 individuals recruited for nonantiarrhythmic drug exposure phenotypes from October 5, 2012, to September 30, 2013, for the Electronic Medical Records and Genomics Network Pharmacogenomics project from 7 US academic medical centers. Variants in SCN5A and KCNH2, disease genes for long QT and Brugada syndromes, were assessed for potential pathogenicity by 3 laboratories with ion channel expertise and by comparison with the ClinVar database. Relevant phenotypes were determined from EMRs, with data available from 2002 (or earlier for some sites) through September 10, 2014. One or more variants designated as pathogenic in SCN5A or KCNH2. Arrhythmia or electrocardiographic (ECG) phenotypes defined by International Classification of Diseases, Ninth Revision (ICD-9) codes, ECG data, and manual EMR review. Among 2022 study participants (median age, 61 years [interquartile range, 56-65 years]; 1118 [55%] female; 1491 [74%] white), a total of 122 rare (minor allele frequency <0.5%) nonsynonymous and splice-site variants in 2 arrhythmia susceptibility genes were identified in 223 individuals (11% of the study cohort). Forty-two variants in 63 participants were designated potentially pathogenic by at least 1 laboratory or ClinVar, with low concordance across laboratories (Cohen κ = 0.26). An ICD-9 code for arrhythmia was found in 11 of 63 (17%) variant carriers vs 264 of 1959 (13%) of those without variants (difference, +4%; 95% CI, -5% to +13%; P = .35). In the 1270 (63%) with ECGs, corrected QT intervals were not different in variant carriers vs those without (median, 429 vs 439 milliseconds; difference, -10 milliseconds; 95% CI, -16 to +3 milliseconds; P = .17). After manual review, 22 of 63 participants (35%) with designated variants had any ECG or arrhythmia phenotype, and only 2 had corrected QT interval longer than 500 milliseconds. Among laboratories experienced in genetic testing for cardiac arrhythmia disorders, there was low concordance in designating SCN5A and KCNH2 variants as pathogenic. In an unselected population, the putatively pathogenic genetic variants were not associated with an abnormal phenotype. These findings raise questions about the implications of notifying patients of incidental genetic findings.

  9. Pregnancy in women with hypertrophic cardiomyopathy: data from the European Society of Cardiology initiated Registry of Pregnancy and Cardiac disease (ROPAC).

    PubMed

    Goland, S; van Hagen, I M; Elbaz-Greener, G; Elkayam, U; Shotan, A; Merz, W M; Enar, S C; Gaisin, I R; Pieper, P G; Johnson, M R; Hall, R; Blatt, A; Roos-Hesselink, J W

    2017-09-14

    We report the maternal and foetal outcomes at birth and after 6 months in a cohort of pregnant women with hypertrophic cardiomyopathy (HCM). Although most women with HCM tolerate pregnancy well, there is an increased risk of obstetric and cardiovascular complications. All pregnant women with HCM entered into the prospective worldwide Registry of Pregnancy and Cardiac disease (ROPAC) were included in this analysis. The primary endpoint was a major adverse cardiovascular event (MACE), which included death, heart failure (HF), thrombo-embolic event, and arrhythmia. Baseline and outcome data were analysed and compared for patients with MACE vs. without MACE and for patients with obstructive HCM vs. non-obstructive HCM. Sixty pregnant women (mean age 30.4 ± 6.0 years) with HCM (41.7% obstructive) were included. No maternal mortality occurred in this cohort. In 14 (23%) patients at least one MACE occurred: 9 (15.0%) HF and 7 (12%) an arrhythmia (6 ventricular and 1 atrial fibrillation). MACE occurred most commonly during the 3rd trimester and postpartum period. In total, 3 (5.0%) women experienced foetal loss. Women with MACE had a higher rate of emergency Caesarean delivery for cardiac reasons (21.4% vs. 0%, P = 0.01). No significant differences in pregnancy outcome were found between women with obstructive and non-obstructive HCM. NYHA functional class of ≥II and signs of HF before pregnancy, were associated with MACE. Although most women with HCM tolerated pregnancy well, cardiovascular complications were not uncommon and predicted by pre-pregnancy status facilitating pre-pregnancy counselling and targeted antenatal care. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.

  10. Electrotonic remodeling following myocardial infarction in dogs susceptible and resistant to sudden cardiac death.

    PubMed

    Del Rio, Carlos L; McConnell, Patrick I; Kukielka, Monica; Dzwonczyk, Roger; Clymer, Bradley D; Howie, Michael B; Billman, George E

    2008-02-01

    Passive electrical remodeling following myocardial infarction (MI) is well established. These changes can alter electrotonic loading and trigger the remodeling of repolarization currents, a potential mechanism for ventricular fibrillation (VF). However, little is known about the role of passive electrical markers as tools to identify VF susceptibility post-MI. This study investigated electrotonic remodeling in the post-MI ventricle, as measured by myocardial electrical impedance (MEI), in animals prone to and resistant to VF. MI was induced in dogs by a two-stage left anterior descending (LAD) coronary artery ligation. Before infarction, MEI electrodes were placed in remote (left circumflex, LCX) and infarcted (LAD) myocardium. MEI was measured in awake animals 1, 2, 7, and 21 days post-MI. Subsequently, VF susceptibility was tested by a 2-min LCX occlusion during exercise; 12 animals developed VF (susceptible, S) and 12 did not (resistant, R). The healing infarct had lower MEI than the normal myocardium. This difference was stable by day 2 post-MI (287 +/- 32 Omega vs. 425 +/- 62 Omega, P < 0.05). Significant differences were observed between resistant and susceptible animals 7 days post-MI; susceptible dogs had a wider electrotonic gradient between remote and infarcted myocardium (R: 89 +/- 60 Omega vs. S: 180 +/- 37 Omega). This difference increased over time in susceptible animals (252 +/- 53 Omega at 21 days) due to post-MI impedance changes on the remote myocardium. These data suggest that early electrotonic changes post-MI could be used to assess later arrhythmia susceptibility. In addition, passive-electrical changes could be a mechanism driving active-electrical remodeling post-MI, thereby facilitating the induction of arrhythmias.

  11. The role of spatial organization of Ca2+ release sites in the generation of arrhythmogenic diastolic Ca2+ release in myocytes from failing hearts

    PubMed Central

    Ho, Hsiang-Ting; Bonilla, Ingrid M.; Terentyeva, Radmila; Schober, Karsten E.; Terentyev, Dmitry; Carnes, Cynthia A.

    2018-01-01

    In heart failure (HF), dysregulated cardiac ryanodine receptors (RyR2) contribute to the generation of diastolic Ca2+ waves (DCWs), thereby predisposing adrenergically stressed failing hearts to life-threatening arrhythmias. However, the specific cellular, subcellular, and molecular defects that account for cardiac arrhythmia in HF remain to be elucidated. Patch-clamp techniques and confocal Ca2+ imaging were applied to study spatially defined Ca2+ handling in ventricular myocytes isolated from normal (control) and failing canine hearts. Based on their activation time upon electrical stimulation, Ca2+ release sites were categorized as coupled, located in close proximity to the sarcolemmal Ca2+ channels, and uncoupled, the Ca2+ channel-free non-junctional Ca2+ release units. In control myocytes, stimulation of β-adrenergic receptors with isoproterenol (Iso) resulted in a preferential increase in Ca2+ spark rate at uncoupled sites. This site-specific effect of Iso was eliminated by the phosphatase inhibitor okadaic acid, which caused similar facilitation of Ca2+ sparks at coupled and uncoupled sites. Iso-challenged HF myocytes exhibited increased predisposition to DCWs compared to control myocytes. In addition, the overall frequency of Ca2+ sparks was increased in HF cells due to preferential stimulation of coupled sites. Furthermore, coupled sites exhibited accelerated recovery from functional refractoriness in HF myocytes compared to control myocytes. Spatially resolved subcellular Ca2+ mapping revealed that DCWs predominantly originated from coupled sites. Inhibition of CaMK∏ suppressed DCWs and prevented preferential stimulation of coupled sites in Iso-challenged HF myocytes. These results suggest that CaMK∏-(and phosphatase)-dependent dysregulation of junctional Ca2+ release sites contributes to Ca2+-dependent arrhythmogenesis in HF. PMID:28612155

  12. Executive Functions Impact the Relation between Respiratory Sinus Arrhythmia and Frequency of Stuttering in Young Children Who Do and Do Not Stutter

    ERIC Educational Resources Information Center

    Jones, Robin M.; Walden, Tedra A.; Conture, Edward G.; Erdemir, Aysu; Lambert, Warren E.; Porges, Stephen W.

    2017-01-01

    Purpose: This study sought to determine whether respiratory sinus arrhythmia (RSA) and executive functions are associated with stuttered speech disfluencies of young children who do (CWS) and do not stutter (CWNS). Method: Thirty-six young CWS and 36 CWNS were exposed to neutral, negative, and positive emotion-inducing video clips, followed by…

  13. Impact of arrhythmia on diagnostic performance of adenosine stress CMR in patients with suspected or known coronary artery disease.

    PubMed

    Greulich, Simon; Steubing, Hannah; Birkmeier, Stefan; Grün, Stefan; Bentz, Kerstin; Sechtem, Udo; Mahrholdt, Heiko

    2015-11-05

    The diagnostic performance of adenosine stress cardiovascular magnetic resonance (CMR) in patients with arrhythmias presenting for work-up of suspected or known CAD is largely unknown, since most CMR studies currently available exclude arrhythmic patients from analysis fearing gating problems, or other artifacts will impair image quality. The primary aim of our study was to evaluate the diagnostic performance of adenosine stress CMR for detection of significant coronary stenosis in patients with arrhythmia presenting for 1) work-up of suspected coronary artery disease (CAD), or 2) work-up of ischemia in known CAD. Patients with arrhythmia referred for work-up of suspected CAD or work-up of ischemia in known CAD undergoing adenosine stress CMR were included if they had coronary angiography within four weeks of CMR. One hundred fifty-nine patients were included (n = 64 atrial fibrillation, n = 87 frequent ventricular extrasystoles, n = 8 frequent supraventricular extrasystoles). Of these, n = 72 had suspected CAD, and n = 87 had known CAD. Diagnostic accuracy of the adenosine stress CMR for detection of significant CAD was 73 % for the entire population (sensitivity 72 %, specificity 76 %). Diagnostic accuracy was 75 % (sensitivity 80 %, specificity 74 %) in patients with suspected CAD, and 74 % (sensitivity 71 %, specificity 79 %) in the group with known CAD. For different types of arrhythmia, diagnostic accuracy of CMR was 70 % in the atrial fibrillation group, and 79 % in patients with ventricular extrasystoles. On a per coronary territory analysis, diagnostic accuracy of CMR was 77 % for stenosis of the left and 82 % for stenosis of the right coronary artery. The present data demonstrates good diagnostic performance of adenosine stress CMR for detection of significant coronary stenosis in patients with arrhythmia presenting for work-up of suspected CAD, or work-up of ischemia in known CAD. This holds true for a per patient, as well as for a per coronary territory analysis.

  14. Frailty syndrome: an emerging clinical problem in the everyday management of clinical arrhythmias. The results of the European Heart Rhythm Association survey.

    PubMed

    Fumagalli, Stefano; Potpara, Tatjana S; Bjerregaard Larsen, Torben; Haugaa, Kristina H; Dobreanu, Dan; Proclemer, Alessandro; Dagres, Nikolaos

    2017-11-01

    The age of patients presenting with complex arrhythmias is increasing. Frailty is a multifaceted syndrome characterized by an increased vulnerability to stressors and a decreased ability to maintain homeostasis. The prevalence of frailty is associated with age. The aims of this European Heart Rhythm Association (EHRA) EP Wire survey were to evaluate the proportion of patients with frailty and its influence on the clinical management of arrhythmias. A total of 41 centres-members of the EHRA Electrophysiology Research Network-in 14 European countries completed the web-based questionnaire in June 2017. Patients over 70 years represented 53% of the total treated population, with the proportion of frail elderly individuals reaching approximately 10%; 91.7% of the responding centres reported treating frail subjects in the previous year. The respondents usually recognized frailty based on the presence of problems of mobility, nutrition, and cognition and inappropriate loss of body weight and muscle mass. Renal failure, dementia, disability, atrial fibrillation, heart failure, falls, and cancer were reported to characterize the elderly frail individuals. Atrial fibrillation was considered the prevalent arrhythmia associated with frailty by 72% of the responding centres, and for stroke prevention, non-vitamin K antagonist oral anticoagulants were preferred. None of the respondents considered withholding the prevention of thrombo-embolic events in subjects with a history of falls. All participants have agreed that cardiac resynchronization therapy exerts positive effects including improvement in cardiac, physical, and cognitive performance and quality of life. The majority of respondents preferred an Arrhythmia Team to manage this special population of elderly patients, and many would like having a simple tool to quickly assess the presence of frailty to guide their decisions, particularly on the use of complex cardiac implantable electrical devices (CIEDs). In conclusion, the complex clinical condition in frail patients presenting with arrhythmias warrants an integrated multidisciplinary approach both for the management of rhythm disturbances and for the decision on using CIEDs. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.

  15. Electrical Integration of Human Embryonic Stem Cell-Derived Cardiomyocytes in a Guinea Pig Chronic Infarct Model

    PubMed Central

    Shiba, Yuji; Filice, Dominic; Fernandes, Sarah; Minami, Elina; Dupras, Sarah K.; Van Biber, Benjamin; Trinh, Peter; Hirota, Yusuke; Gold, Joseph D.; Viswanathan, Mohan; Laflamme, Michael A.

    2014-01-01

    Background Human embryonic stem cell-derived cardiomyocytes (hESC-CMs) were recently shown to be capable of electromechanical integration following their direct injection into intact or recently injured guinea pig hearts, and hESC-CM transplantation in recently injured hearts correlated with improvements in contractile function and a reduction in the incidence of arrhythmias. The present study was aimed at determining the ability of hESC-CMs to integrate and modulate electrical stability following transplantation in a chronic model of cardiac injury. Methods & Results At 28 days following cardiac cryoinjury, guinea pigs underwent intra-cardiac injection of hESC-CMs, non-cardiac hESC-derivatives (non-CMs) or vehicle. Histology confirmed partial remuscularization of the infarct zone in hESC-CM recipients, while non-CM recipients showed heterogeneous xenografts. The three experimental groups showed no significant difference in the left ventricular dimensions or fractional shortening by echocardiography or in the incidence of spontaneous arrhythmias by telemetric monitoring. While recipients of hESC-CMs and vehicle showed a similar incidence of arrhythmias induced by programmed electrical stimulation at 4-weeks post-transplantation, non-CM recipients proved to be highly inducible, with a ~3-fold greater incidence of induced arrhythmias. In parallel studies, we investigated the ability of hESC-CMs to couple with host myocardium in chronically injured hearts by the intravital imaging of hESC-CM grafts that stably expressed a fluorescent reporter of graft activation, the genetically-encoded calcium sensor GCaMP3. In this work, we found that only ~38% (5 of 13) of recipients of GCaMP3+ hESC-CMs showed fluorescent transients that were coupled to the host electrocardiogram. Conclusions hESC-CMs engraft in chronically injured hearts without increasing the incidence of arrhythmias, but their electromechanical integration is more limited than was previously reported following their transplantation in a subacute injury model. Moreover, non-CM grafts may promote arrhythmias under certain conditions, a finding that underscores the need for input preparations of high cardiac purity. PMID:24516260

  16. Family history of atrial fibrillation as a predictor of atrial substrate and arrhythmia recurrence in patients undergoing atrial fibrillation catheter ablation.

    PubMed

    Kapur, Sunil; Kumar, Saurabh; John, Roy M; Stevenson, William G; Tedrow, Usha B; Koplan, Bruce A; Epstein, Laurence M; MacRae, Calum A; Michaud, Gregory F

    2018-06-01

    A commonly held notion is that patients with a family history of atrial fibrillation (AF) have worse atrial substrate and higher rates of arrhythmia recurrence following ablation. We sought to examine differences in atrial substrate and catheter ablation outcomes in patients with a 1st degree family member with paroxysmal or persistent AF (PeAF) compared to those without. A total of 256 consecutive patients undergoing their 1st ablation for AF (123 paroxysmal, 133 persistent) with >1 year follow up were included. The presence of one 1st-degree family relative was defined as a 'positive family history'. Clinical characteristics, electroanatomic map findings, ablation characteristics and outcomes were compared in patients with and without a positive family history of AF. Patients with paroxysmal fibrillation with a positive family history (n = 57; 46%) had similar clinical characteristics and arrhythmia recurrence after catheter ablation as those without. Of those that recurred, patients with a positive family history were more likely to have progressed to PeAF (P = 0.05). Patients with PeAF with a positive family history (n = 75; 56%) had similar clinical characteristics, electroanatomic mapping findings and ablation characteristics, but worse long term arrhythmia free survival (P = 0.04). The presence of a 1st-degree family member with AF does not impact the clinical outcomes of catheter ablation for paroxysmal AF. However, a positive family history is associated with worse arrhythmia free survival in patients with PeAF. This finding is not explained by differences in clinical characteristics, atrial substrate assessed by voltage maps or ablation characteristics.

  17. An electrocardiographic scoring system for distinguishing right ventricular outflow tract arrhythmias in patients with arrhythmogenic right ventricular cardiomyopathy from idiopathic ventricular tachycardia.

    PubMed

    Hoffmayer, Kurt S; Bhave, Prashant D; Marcus, Gregory M; James, Cynthia A; Tichnell, Crystal; Chopra, Nagesh; Moxey, Laura; Krahn, Andrew D; Dixit, Sanjay; Stevenson, William; Calkins, Hugh; Badhwar, Nitish; Gerstenfeld, Edward P; Scheinman, Melvin M

    2013-04-01

    Ventricular arrhythmias in patients with arrhythmogenic right ventricular dysplasia/cardiomyopathy (ARVD/C) and idiopathic ventricular tachycardia (VT) can share a left bundle branch block/inferior axis morphology. We previously reported electrocardiogram characteristics during outflow tract ventricular arrhythmias that helped distinguish VT related to ARVD/C from idiopathic VT. To prospectively validate these criteria. We created a risk score by using a derivation cohort. Two experienced electrophysiologists blinded to the diagnosis prospectively scored patients with VT/premature ventricular contractions (PVCs) with left bundle branch block/inferior axis pattern in a validation cohort of 37 ARVD/C tracings and 49 idiopathic VT tracings. All patients with ARVD/C had their diagnosis confirmed based on the revised task force criteria. Patients with idiopathic VT were selected based on structurally normal hearts with documented right ventricular outflow tract VT successfully treated with ablation. The scoring system provides 3 points for sinus rhythm anterior T-wave inversions in leads V1-V3 and during ventricular arrhythmia: 2 points for QRS duration in lead I≥120 ms, 2 points for QRS notching, and 1 point for precordial transition at lead V5 or later. A score of 5 or greater was able to correctly distinguish ARVD/C from idiopathic VT 93% of the time, with a sensitivity of 84%, specificity of 100%, positive predictive value of 100%, and negative predictive value of 91%. We describe a simple scoring algorithm that uses 12-lead electrocardiogram characteristics to effectively distinguish right ventricular outflow tract arrhythmias originating from patients with ARVD/C versus patients with idiopathic VT. Copyright © 2013 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  18. Screening drug-induced arrhythmia [corrected] using human induced pluripotent stem cell-derived cardiomyocytes and low-impedance microelectrode arrays.

    PubMed

    Navarrete, Enrique G; Liang, Ping; Lan, Feng; Sanchez-Freire, Verónica; Simmons, Chelsey; Gong, Tingyu; Sharma, Arun; Burridge, Paul W; Patlolla, Bhagat; Lee, Andrew S; Wu, Haodi; Beygui, Ramin E; Wu, Sean M; Robbins, Robert C; Bers, Donald M; Wu, Joseph C

    2013-09-10

    Drug-induced arrhythmia is one of the most common causes of drug development failure and withdrawal from market. This study tested whether human induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs) combined with a low-impedance microelectrode array (MEA) system could improve on industry-standard preclinical cardiotoxicity screening methods, identify the effects of well-characterized drugs, and elucidate underlying risk factors for drug-induced arrhythmia. hiPSC-CMs may be advantageous over immortalized cell lines because they possess similar functional characteristics as primary human cardiomyocytes and can be generated in unlimited quantities. Pharmacological responses of beating embryoid bodies exposed to a comprehensive panel of drugs at 65 to 95 days postinduction were determined. Responses of hiPSC-CMs to drugs were qualitatively and quantitatively consistent with the reported drug effects in literature. Torsadogenic hERG blockers, such as sotalol and quinidine, produced statistically and physiologically significant effects, consistent with patch-clamp studies, on human embryonic stem cell-derived cardiomyocytes hESC-CMs. False-negative and false-positive hERG blockers were identified accurately. Consistent with published studies using animal models, early afterdepolarizations and ectopic beats were observed in 33% and 40% of embryoid bodies treated with sotalol and quinidine, respectively, compared with negligible early afterdepolarizations and ectopic beats in untreated controls. We found that drug-induced arrhythmias can be recapitulated in hiPSC-CMs and documented with low impedance MEA. Our data indicate that the MEA/hiPSC-CM assay is a sensitive, robust, and efficient platform for testing drug effectiveness and for arrhythmia screening. This system may hold great potential for reducing drug development costs and may provide significant advantages over current industry standard assays that use immortalized cell lines or animal models.

  19. Associations between arrhythmia episodes and temporally and spatially resolved black carbon and particulate matter in elderly patients

    PubMed Central

    Zanobetti, Antonella; Coull, Brent A.; Gryparis, Alexandros; Kloog, Itai; Sparrow, David; Vokonas, Pantel S; Wright, Robert O.; Gold, Diane R; Schwartz, Joel

    2015-01-01

    Objectives Ambient air pollution has been associated with sudden deaths, some of which are likely due to ventricular arrhythmias. Defibrillator discharge studies have examined the association of air pollution with arrhythmias in sensitive populations. No studies have assessed this association using residence-specific estimates of air pollution exposure. Methods In the Normative Aging Study, we investigated the association between temporally-and spatially-resolved black carbon (BC) and PM2.5 and arrhythmia episodes (bigeminy, trigeminy or couplets episodes) measured as ventricular ectopy (VE) by 4-min electrocardiogram (ECG) monitoring in repeated measures of 701 subjects, during the years 2000 to 2010. We used a binomial distribution (having or not a VE episode) in a mixed effect model with a random intercept for subject, controlling for seasonality, temperature, day of the week, medication use, smoking, having diabetes, BMI and age. We also examined whether these associations were modified by genotype or phenotype. Results We found significant increases in VE with both pollutants and lags; for the estimated concentration averaged over the three days prior to the health assessment we found increases in the odds of having VE with an OR of 1.52 (95% CI: 1.19–1.94) for an IQR (0.30 μg/m3) increase in BC and an OR of 1.39 (95% CI: 1.12–1.71) for an IQR (5.63 μg/m3) increase in PM2.5. We also found higher effects in subjects with the GSTT1 and GSTM1 variants and in obese (P-values<0.05). Conclusion Increased levels of short-term traffic related pollutants may increase the risk of ventricular arrhythmia in elderly subjects. PMID:24142987

  20. The cardiomyocyte molecular clock, regulation of Scn5a, and arrhythmia susceptibility

    PubMed Central

    Lefta, Mellani; Zhang, Xiping; Bartos, Daniel; Feng, Han-Zhong; Zhao, Yihua; Patwardhan, Abhijit; Jin, Jian-Ping; Esser, Karyn A.; Delisle, Brian P.

    2013-01-01

    The molecular clock mechanism underlies circadian rhythms and is defined by a transcription-translation feedback loop. Bmal1 encodes a core molecular clock transcription factor. Germline Bmal1 knockout mice show a loss of circadian variation in heart rate and blood pressure, and they develop dilated cardiomyopathy. We tested the role of the molecular clock in adult cardiomyocytes by generating mice that allow for the inducible cardiomyocyte-specific deletion of Bmal1 (iCSΔBmal1). ECG telemetry showed that cardiomyocyte-specific deletion of Bmal1 (iCSΔBmal1−/−) in adult mice slowed heart rate, prolonged RR and QRS intervals, and increased episodes of arrhythmia. Moreover, isolated iCSΔBmal1−/− hearts were more susceptible to arrhythmia during electromechanical stimulation. Examination of candidate cardiac ion channel genes showed that Scn5a, which encodes the principle cardiac voltage-gated Na+ channel (NaV1.5), was circadianly expressed in control mouse and rat hearts but not in iCSΔBmal1−/− hearts. In vitro studies confirmed circadian expression of a human Scn5a promoter-luciferase reporter construct and determined that overexpression of clock factors transactivated the Scn5a promoter. Loss of Scn5a circadian expression in iCSΔBmal1−/− hearts was associated with decreased levels of NaV1.5 and Na+ current in ventricular myocytes. We conclude that disruption of the molecular clock in the adult heart slows heart rate, increases arrhythmias, and decreases the functional expression of Scn5a. These findings suggest a potential link between environmental factors that alter the cardiomyocyte molecular clock and factors that influence arrhythmia susceptibility in humans. PMID:23364267

  1. Complications of intra-cardial placement of silastic central venous catheter in pediatric patients.

    PubMed

    Soong, W J; Jeng, M J; Hwang, B

    1996-01-01

    A three-year prospective study was undertaken to determine the incidence and early complications from intra-cardiac placement of percutaneous central venous catheter (CVC). CVC was inserted by using "Catheter-through-needle" technique, and the insertion length was measured by body surface landmark. CVC course and tip location were routinely checked by roentgenography. Echocardiography was performed in case of arrhythmia. After analysis of 784 CVCs, 104 (13.3%) were proved to be intra-cardial, as located by either roentgenography or echocardiography. However, catheters passed via the upper trunk (14.5%) were significantly (p < 0.05) more intra-cardially located than those via the lower trunk (4.8%). Catheters which passed via the right upper trunk veins (basilic, cephalic, or external jugular veins) were also more intra-cardially located than those via their left veins counterparts, but the finding was not statistically significant (p > 0.05). The mean body weight (3.1 +/- 2.4 kg) in the intra-cardial placement group was significantly (p < 0.05) less than that in the non-intracardial placement group (7.9 +/- 4.5 kg). In intra-cardial placement patients, 32 cases (30.8%) had episode(s) of cardiac arrhythmia including 31 premature ventricular depolarization and 1 supra-ventricular tachycardia. All cases showed the presence of intra-ventricular catheter. All arrhythmias ceased abruptly after the catheters were pulled from the hearts. No other early complications were observed. the incidence of the intracardiac placement of CVC is high, especially in small infants or when the insertion via the upper trunk. Short term intra-cardiac catheter placement has a benign clinical course except that the intraventricular catheter may cause arrhythmia. However, this kind of arrhythmia can be resolved spontaneously by withdrawing the catheter.

  2. Sex- and gender-specific research priorities for the emergency management of heart failure and acute arrhythmia: proceedings from the 2014 Academic Emergency Medicine Consensus Conference Cardiovascular Research Workgroup.

    PubMed

    McGregor, Alyson J; Frank Peacock, W; Marie Chang, Anna; Safdar, Basmah; Diercks, Deborah

    2014-12-01

    The emergency department (ED) is the point of first contact for patients with acute heart failure and arrhythmias, with 1 million annual ED visits in the United States. Although the total numbers of men and women living with heart failure are similar, female patients are underrepresented in clinical studies, with current knowledge predominantly based on data from male patients. This has led to an underappreciation of the sex-specific differences in clinical characteristics and pathophysiology-based management of heart failure. Similar disparities have been found in management of acute arrhythmias, especially atrial arrhythmias that lead to an increased risk of stroke in women. Additionally, peripartum and postpartum cardiomyopathy represent a diagnostic and treatment dilemma. This article is the result of a breakout session in the cardiovascular and resuscitation work group of the 2014 Academic Emergency Medicine consensus conference "Gender-Specific Research in Emergency Medicine: Investigate, Understand, and Translate How Gender Affects Patient Outcomes." A nominal group technique was used to identify and prioritize themes and research questions using electronic mail, monthly conference calls, in-person meetings, and Web-based surveys between June 2013 and May 2014. Consensus was achieved through three rounds of nomination followed by the meeting on May 13, 2014, and resulted in seven priority themes that are essential to the common complex clinical syndrome of heart failure for both men and women and include the areas of pathophysiology; presentation and symptomatology; and diagnostic strategies using biomarkers, treatment, and mortality, with special consideration to arrhythmia management and pregnancy. © 2014 by the Society for Academic Emergency Medicine.

  3. Ryanodine receptor phosphorylation by calcium/calmodulin-dependent protein kinase II promotes life-threatening ventricular arrhythmias in mice with heart failure.

    PubMed

    van Oort, Ralph J; McCauley, Mark D; Dixit, Sayali S; Pereira, Laetitia; Yang, Yi; Respress, Jonathan L; Wang, Qiongling; De Almeida, Angela C; Skapura, Darlene G; Anderson, Mark E; Bers, Donald M; Wehrens, Xander H T

    2010-12-21

    approximately half of patients with heart failure die suddenly as a result of ventricular arrhythmias. Although abnormal Ca(2+) release from the sarcoplasmic reticulum through ryanodine receptors (RyR2) has been linked to arrhythmogenesis, the molecular mechanisms triggering release of arrhythmogenic Ca(2+) remain unknown. We tested the hypothesis that increased RyR2 phosphorylation by Ca(2+)/calmodulin-dependent protein kinase II is both necessary and sufficient to promote lethal ventricular arrhythmias. mice in which the S2814 Ca(2+)/calmodulin-dependent protein kinase II site on RyR2 is constitutively activated (S2814D) develop pathological sarcoplasmic reticulum Ca(2+) release events, resulting in reduced sarcoplasmic reticulum Ca(2+) load on confocal microscopy. These Ca(2+) release events are associated with increased RyR2 open probability in lipid bilayer preparations. At baseline, young S2814D mice have structurally and functionally normal hearts without arrhythmias; however, they develop sustained ventricular tachycardia and sudden cardiac death on catecholaminergic provocation by caffeine/epinephrine or programmed electric stimulation. Young S2814D mice have a significant predisposition to sudden arrhythmogenic death after transverse aortic constriction surgery. Finally, genetic ablation of the Ca(2+)/calmodulin-dependent protein kinase II site on RyR2 (S2814A) protects mutant mice from pacing-induced arrhythmias versus wild-type mice after transverse aortic constriction surgery. our results suggest that Ca(2+)/calmodulin-dependent protein kinase II phosphorylation of RyR2 Ca(2+) release channels at S2814 plays an important role in arrhythmogenesis and sudden cardiac death in mice with heart failure.

  4. Noninvasive imaging of three-dimensional cardiac activation sequence during pacing and ventricular tachycardia.

    PubMed

    Han, Chengzong; Pogwizd, Steven M; Killingsworth, Cheryl R; He, Bin

    2011-08-01

    Imaging cardiac excitation within ventricular myocardium is important in the treatment of cardiac arrhythmias and might help improve our understanding of arrhythmia mechanisms. This study sought to rigorously assess the imaging performance of a 3-dimensional (3D) cardiac electrical imaging (3DCEI) technique with the aid of 3D intracardiac mapping from up to 216 intramural sites during paced rhythm and norepinephrine (NE)-induced ventricular tachycardia (VT) in the rabbit heart. Body surface potentials and intramural bipolar electrical recordings were simultaneously measured in a closed-chest condition in 13 healthy rabbits. Single-site pacing and dual-site pacing were performed from ventricular walls and septum. VTs and premature ventricular complexes (PVCs) were induced by intravenous NE. Computed tomography images were obtained to construct geometry models. The noninvasively imaged activation sequence correlated well with invasively measured counterpart, with a correlation coefficient of 0.72 ± 0.04, and a relative error of 0.30 ± 0.02 averaged over 520 paced beats as well as 73 NE-induced PVCs and VT beats. All PVCs and VT beats initiated in the subendocardium by a nonreentrant mechanism. The averaged distance from the imaged site of initial activation to the pacing site or site of arrhythmias determined from intracardiac mapping was ∼5 mm. For dual-site pacing, the double origins were identified when they were located at contralateral sides of ventricles or at the lateral wall and the apex. 3DCEI can noninvasively delineate important features of focal or multifocal ventricular excitation. It offers the potential to aid in localizing the origins and imaging activation sequences of ventricular arrhythmias, and to provide noninvasive assessment of the underlying arrhythmia mechanisms. Copyright © 2011 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  5. Noninvasive Imaging of Three-dimensional Cardiac Activation Sequence during Pacing and Ventricular Tachycardia

    PubMed Central

    Han, Chengzong; Pogwizd, Steven M.; Killingsworth, Cheryl R.; He, Bin

    2011-01-01

    Background Imaging cardiac excitation within ventricular myocardium is important in the treatment of cardiac arrhythmias and might help improve our understanding of arrhythmia mechanisms. Objective This study aims to rigorously assess the imaging performance of a three-dimensional (3-D) cardiac electrical imaging (3-DCEI) technique with the aid of 3-D intra-cardiac mapping from up to 216 intramural sites during paced rhythm and norepinephrine (NE) induced ventricular tachycardia (VT) in the rabbit heart. Methods Body surface potentials and intramural bipolar electrical recordings were simultaneously measured in a closed-chest condition in thirteen healthy rabbits. Single-site pacing and dual-site pacing were performed from ventricular walls and septum. VTs and premature ventricular complexes (PVCs) were induced by intravenous NE. Computer tomography images were obtained to construct geometry model. Results The non-invasively imaged activation sequence correlated well with invasively measured counterparts, with a correlation coefficient of 0.72±0.04, and a relative error of 0.30±0.02 averaged over 520 paced beats as well as 73 NE-induced PVCs and VT beats. All PVCs and VT beats initiated in the subendocardium by a nonreentrant mechanism. The averaged distance from imaged site of initial activation to pacing site or site of arrhythmias determined from intra-cardiac mapping was ~5mm. For dual-site pacing, the double origins were identified when they were located at contralateral sides of ventricles or at the lateral wall and the apex. Conclusion 3-DCEI can non-invasively delineate important features of focal or multi-focal ventricular excitation. It offers the potential to aid in localizing the origins and imaging activation sequence of ventricular arrhythmias, and to provide noninvasive assessment of the underlying arrhythmia mechanisms. PMID:21397046

  6. Exome-based analysis of cardiac arrhythmia, respiratory control, and epilepsy genes in sudden unexpected death in epilepsy.

    PubMed

    Bagnall, Richard D; Crompton, Douglas E; Petrovski, Slavé; Lam, Lien; Cutmore, Carina; Garry, Sarah I; Sadleir, Lynette G; Dibbens, Leanne M; Cairns, Anita; Kivity, Sara; Afawi, Zaid; Regan, Brigid M; Duflou, Johan; Berkovic, Samuel F; Scheffer, Ingrid E; Semsarian, Christopher

    2016-04-01

    The leading cause of epilepsy-related premature mortality is sudden unexpected death in epilepsy (SUDEP). The cause of SUDEP remains unknown. To search for genetic risk factors in SUDEP cases, we performed an exome-based analysis of rare variants. Demographic and clinical information of 61 SUDEP cases were collected. Exome sequencing and rare variant collapsing analysis with 2,936 control exomes were performed to test for genes enriched with damaging variants. Additionally, cardiac arrhythmia, respiratory control, and epilepsy genes were screened for variants with frequency of <0.1% and predicted to be pathogenic with multiple in silico tools. The 61 SUDEP cases were categorized as definite SUDEP (n = 54), probable SUDEP (n = 5), and definite SUDEP plus (n = 2). We identified de novo mutations, previously reported pathogenic mutations, or candidate pathogenic variants in 28 of 61 (46%) cases. Four SUDEP cases (7%) had mutations in common genes responsible for the cardiac arrhythmia disease, long QT syndrome (LQTS). Nine cases (15%) had candidate pathogenic variants in dominant cardiac arrhythmia genes. Fifteen cases (25%) had mutations or candidate pathogenic variants in dominant epilepsy genes. No gene reached genome-wide significance with rare variant collapsing analysis; however, DEPDC5 (p = 0.00015) and KCNH2 (p = 0.0037) were among the top 30 genes, genome-wide. A sizeable proportion of SUDEP cases have clinically relevant mutations in cardiac arrhythmia and epilepsy genes. In cases with an LQTS gene mutation, SUDEP may occur as a result of a predictable and preventable cause. Understanding the genetic basis of SUDEP may inform cascade testing of at-risk family members. © 2016 American Neurological Association.

  7. Protective effect of Crataegus oxyacantha against reperfusion arrhythmias after global no-flow ischemia in the rat heart.

    PubMed

    al Makdessi, S; Sweidan, H; Dietz, K; Jacob, R

    1999-04-01

    The protective effect against reperfusion arrhythmias of a 3-month oral pretreatment with a dried extract of Crataegus oxyacantha (LI 132)(standardized to 2.2% flavonoids) was studied with the Langendorff heart of the rat after global no-flow ischemia. The heart was perfused with a modified Krebs-Henseleit solution in which the K+ content was reduced to 3.4 mmol/l in order to lower the fibrillation threshold. According to pilot experiments which considered various durations of global no-flow ischemia ranging from 10 to 20 minutes, two durations were chosen for the present study: 20 minutes (group 20) in which ventricular fibrillation (VF) was the predominant form of arrhythmias, and 18 minutes (group 18) in which the prevalence of VF was markedly lower despite the small difference in the duration of ischemia. Crataegus pretreatment significantly (p = 0.02) reduced the average prevalence of malignant arrhythmias (VF + Flutter) as observed during the 20-min-period of reperfusion as follows: group 20: from 89% (control, n = 9) to 51% (LI 132, n = 7), group 18: from 48% (control, n = 8) to 8% (LI 132, n = 8). In group 20, ventricular tachycardia (VT) could be observed only in the treated group, because of the predominance of VF in the control group. LI 132 pretreatment reduced the average prevalence of VT in group 18 in spite of the identical percentage of occurrence (6 out of 8 rats, with and without treatment) due to a shorter duration of the VT episodes. Thus, under the conditions of our experiments, effective prevention against reperfusion arrhythmias by Crataegus pretreatment was evident.

  8. Obesity and exercise-induced ectopic ventricular arrhythmias in apparently healthy middle aged adults.

    PubMed

    Sabbag, Avi; Sidi, Yechezkel; Kivity, Shaye; Beinart, Roy; Glikson, Michael; Segev, Shlomo; Goldenberg, Ilan; Maor, Elad

    2016-03-01

    Obesity and overweight are strongly associated with cardiovascular morbidity and mortality. However, there are limited data on the association between excess weight and the risk of ectopic ventricular activity. We investigated the association between body mass index (BMI) and the risk for ectopic ventricular activity (defined as multiple ventricular premature beats (≥3), ventricular bigeminy, nonsustained ventricular tachycardia or sustained ventricular tachycardia) during exercise stress testing among 22,516 apparently healthy men and women who attended periodic health screening examinations between the years 2000 and 2014. All subjects had completed maximal exercise stress testing annually according to the Bruce protocol. Subjects were divided at baseline into three groups: normal weight (BMI ≥ 18.5 kg/m(2) and<25; N = 9,994), overweight (BMI ≥ 25 and < 30; N = 9,613) and obese (BMI ≥ 30; N = 2,906). The mean age of study subjects was 47 ± 10 years and 72% were men. Kaplan-Meier survival analysis showed that the cumulative probability for the development of exercise-induced ectopic ventricular activity arrhythmias was highest among obese subjects, intermediate among overweight subjects and lowest among subjects with normal weight (3.4%, 2.7% and 2.2% respectively; p < 0.001). Multivariate binary logistic regression with repeated measures of 92,619 ESTs, showed that obese subjects were 33% more likely to have ectopic ventricular arrhythmias during exercise compared with subjects with normal weight (p = 0.005), and that each 1 kg/m(2) increase in BMI was associated with a significant 4% (p = 0.002) increased adjusted risk for exercise-induced ventricular arrhythmias. Obesity is independently associated with increased likelihood of ectopic ventricular arrhythmia during exercise. © The European Society of Cardiology 2015.

  9. Beneficial effects of l-leucine and l-valine on arrhythmias, hemodynamics and myocardial morphology in rats.

    PubMed

    Mitręga, Katarzyna; Zorniak, Michał; Varghese, Benoy; Lange, Dariusz; Nożynski, Jerzy; Porc, Maurycy; Białka, Szymon; Krzemiński, Tadeusz F

    2011-09-01

    Branched chain amino acids (BCAA) have been shown to have a general protective effect on the heart in different animal models as well as in humans. However, so far no attempt has been made to specifically elucidate their influence on arrhythmias. Our study was performed to evaluate whether an infusion of either l-leucine or l-valine in a dose of 1mgkg(-1)h(-1) 10min before a 7-min period of left anterior descending artery occlusion followed by 15min of reperfusion, had an effect on arrhythmias measured during the reperfusion phase in the ischemia- and reperfusion-induced arrhythmias model in rats in vivo. The effect of the infusion of these substances on mean arterial blood pressure was monitored throughout the experiment. Both of the tested amino acids exhibited significant antiarrhythmic properties. l-Leucine reduced the duration of ventricular fibrillation (P<0.05) and l-valine decreased the duration of ventricular fibrillation (P<0.001) and ventricular tachycardia (P<0.05). The two amino acids were generally hypotensive. l-Valine lowered blood pressure in all phases of the experiment (P<0.05) while l-leucine lowered this parameter mainly towards the end of occlusion and reperfusion (P<0.05). In addition, 30min infusion of the amino acids in the used dose did not produce any apparent adverse histological changes that were remarkably different from control. In summary, the results of our study suggest that l-leucine and l-valine in the dose that was used attenuates arrhythmias and are hypotensive in their influence. Our findings lend support to the many ongoing investigations into the benefit of the application of l-leucine and l-valine in cardiology like their addition to cardioplegic solutions. 2011 Elsevier Ltd. All rights reserved.

  10. Bidirectional Cardio-Respiratory Interactions in Heart Failure.

    PubMed

    Radovanović, Nikola N; Pavlović, Siniša U; Milašinović, Goran; Kirćanski, Bratislav; Platiša, Mirjana M

    2018-01-01

    We investigated cardio-respiratory coupling in patients with heart failure by quantification of bidirectional interactions between cardiac (RR intervals) and respiratory signals with complementary measures of time series analysis. Heart failure patients were divided into three groups of twenty, age and gender matched, subjects: with sinus rhythm (HF-Sin), with sinus rhythm and ventricular extrasystoles (HF-VES), and with permanent atrial fibrillation (HF-AF). We included patients with indication for implantation of implantable cardioverter defibrillator or cardiac resynchronization therapy device. ECG and respiratory signals were simultaneously acquired during 20 min in supine position at spontaneous breathing frequency in 20 healthy control subjects and in patients before device implantation. We used coherence, Granger causality and cross-sample entropy analysis as complementary measures of bidirectional interactions between RR intervals and respiratory rhythm. In heart failure patients with arrhythmias (HF-VES and HF-AF) there is no coherence between signals ( p < 0.01), while in HF-Sin it is reduced ( p < 0.05), compared with control subjects. In all heart failure groups causality between signals is diminished, but with significantly stronger causality of RR signal in respiratory signal in HF-VES. Cross-sample entropy analysis revealed the strongest synchrony between respiratory and RR signal in HF-VES group. Beside respiratory sinus arrhythmia there is another type of cardio-respiratory interaction based on the synchrony between cardiac and respiratory rhythm. Both of them are altered in heart failure patients. Respiratory sinus arrhythmia is reduced in HF-Sin patients and vanished in heart failure patients with arrhythmias. Contrary, in HF-Sin and HF-VES groups, synchrony increased, probably as consequence of some dominant neural compensatory mechanisms. The coupling of cardiac and respiratory rhythm in heart failure patients varies depending on the presence of atrial/ventricular arrhythmias and it could be revealed by complementary methods of time series analysis.

  11. In vivo and in vitro antiarrhythmic effects of SSR149744C in animal models of atrial fibrillation and ventricular arrhythmias.

    PubMed

    Gautier, Patrick; Serre, Martine; Cosnier-Pucheu, Sylvie; Djandjighian, Laurent; Roccon, Alain; Herbert, Jean-Marc; Nisato, Dino

    2005-02-01

    SSR149744C (2-butyl-3-{4-[3-(dibutylamino)propyl]benzoyl}-1-benzofuran-5-carboxylate isopropyl fumarate) is a new noniodinated benzofuran derivative structurally related to amiodarone and dronedarone that is currently undergoing clinical trials as an antiarrhythmic agent. As SSR149744C exhibits electrophysiological and hemodynamic properties of class I, II, III, and IV antiarrhythmic agents, the aim of this study was to evaluate its acute intravenous (IV) or oral (PO) antiarrhythmic activities in in vitro and in vivo animal models of atrial and ventricular arrhythmias. In vagally induced atrial fibrillation (AF) in anesthetized dogs, SSR149744C (3 and 10 mg/kg IV) terminated AF in all 7 dogs and prevented reinduction in 4 out of 7 dogs; effective refractory periods of right atrium were dose-dependently and frequency-independently lengthened. In low-K+ medium-induced AF models, SSR149744C (0.1 to 1 microM) prevented AF in isolated guinea pig hearts in a concentration-dependent manner. At the ventricular level, SSR149744C (0.1 to 10 mg/kg IV and 3 to 90 mg/kg PO) prevented reperfusion-induced arrhythmias in anesthetized rats with a dose-effect relationship, and, at doses of 30 to 90 mg/kg PO, it reduced early (0-24 hours) mortality following permanent left coronary artery ligature in conscious rats. The present results show that SSR149744C is an effective antiarrhythmic agent in atrial fibrillation and in ventricular arrhythmias. Like amiodarone and dronedarone, its efficiency in these animal models of arrhythmias is likely be related to its multifactorial mechanism of action.

  12. The Role of NT-proBNP in the Diagnosis of Ventricular Arrhythmias in Patients with Systemic Sclerosis

    PubMed Central

    MURESAN, Lucian; PETCU, Ana; MURESAN, Crina; RINZIS, Mirela; GUSETU, Gabriel; POP, Dana; ZDRENGHEA, Dumitru; REDNIC, Simona

    2017-01-01

    Background: In patients with systemic sclerosis, NT-proBNP is a useful diagnostic marker for pulmonary hypertension and ventricular dysfunction, with important prognostic significance. The aim of this study was to assess the relationship between the NT-proBNP levels and the presence and severity of ventricular arrhythmias in patients with scleroderma. Methods: Forty consecutive patients with a diagnostic of systemic sclerosis according to the EULAR criteria admitted at the Rheumatology Clinic of Cluj-Napoca, Romania, from Jan 2014 to Apr 2014 were enrolled. Patients underwent a 12-lead ECG and a 24-hour Holter ECG monitoring for ventricular arrhythmias evaluation. Blood sample testing (including NT-proBNP level measurements), echocardiography, spirometry, chest X-ray and, when considered appropriate, high-resolution chest CT were performed. Results: Sixty percent of patients (n=24) had abnormal NT-proBNP serum levels (>125 pg/ml) and 10 patients had >100 PVC/24 h. There was a statistically significant correlation between the NT-proBNP levels and the total number of premature ventricular contractions (PVC) (r=0.445, P=0.006), total number of isolated PVC (r=0,493, P=0.002), total number of ventricular couplets (r=0.379, P=0.021) and the number of PVC morphologies (r=0.501, P=0.002). The presence of an NT-proBNP serum level >287 pg/ml had a sensitivity of 55% and a specificity of 93% in predicting the presence of complex ventricular arrhythmias on 24-hour Holter ECG monitoring. Conclusion: NT-proBNP levels could become a useful ventricular arrhythmia marker for assessing the arrhythmic risk in patients with systemic sclerosis. PMID:28845401

  13. Diagnosis and Treatment of Fetal Arrhythmia

    PubMed Central

    Wacker-Gussmann, Annette; Strasburger, Janette F.; Cuneo, Bettina F.; Wakai, Ronald T.

    2014-01-01

    Detection and careful stratification of fetal heart rate (FHR) is extremely important in all pregnancies. The most lethal cardiac rhythm disturbances occur during apparently normal pregnancies where FHR and rhythmare regular and within normal or low-normal ranges. These hidden depolarization and repolarization abnormalities, associated with genetic ion channelopathies cannot be detected by echocardiography, and may be responsible for up to 10% of unexplained fetal demise, prompting a need for newer and better fetal diagnostic techniques. Other manifest fetal arrhythmias such as premature beats, tachycardia, and bradycardia are commonly recognized. Heart rhythm diagnosis in obstetrical practice is usually made by M-mode and pulsed Doppler fetal echocardiography, but not all fetal cardiac time intervals are captured by echocardiographic methods. This article reviews different types of fetal arrhythmias, their presentation and treatment strategies, and gives an overview of the present and future diagnostic techniques. PMID:24858320

  14. Classification of ECG signal with Support Vector Machine Method for Arrhythmia Detection

    NASA Astrophysics Data System (ADS)

    Turnip, Arjon; Ilham Rizqywan, M.; Kusumandari, Dwi E.; Turnip, Mardi; Sihombing, Poltak

    2018-03-01

    An electrocardiogram is a potential bioelectric record that occurs as a result of cardiac activity. QRS Detection with zero crossing calculation is one method that can precisely determine peak R of QRS wave as part of arrhythmia detection. In this paper, two experimental scheme (2 minutes duration with different activities: relaxed and, typing) were conducted. From the two experiments it were obtained: accuracy, sensitivity, and positive predictivity about 100% each for the first experiment and about 79%, 93%, 83% for the second experiment, respectively. Furthermore, the feature set of MIT-BIH arrhythmia using the support vector machine (SVM) method on the WEKA software is evaluated. By combining the available attributes on the WEKA algorithm, the result is constant since all classes of SVM goes to the normal class with average 88.49% accuracy.

  15. Phenol intoxication in a child.

    PubMed

    Unlü, R Erkin; Alagöz, M Sahin; Uysal, A Caĝri; Orbay, Hakan; Kilinç, Hidir; Tekin, Fatih; Sensöz, Omer; Erk, Gülcan

    2004-11-01

    Phenol preparations are used in dermatology and plastic surgery for the treatment of acne and during chemical face peeling. At this institution, phenol peeling is used in addition to mechanical dermabrasion for the elimination of subclinical premalignant lesions of patients having xeroderma pigmentosum. As the phenol peel is performed, most surgeons concentrate on skin results, ignoring systemic complications. Local histological changes and systemic toxicity have been seen during applications. Cardiac arrhythmias and even sudden death have been reported. The high incidence of cardiac arrhythmias after topical application of phenol preparations is demonstrated. The case of an 11-year-old boy with a diagnosis of xeroderma pigmentosum who underwent mechanical dermabrasion and chemical peeling with phenol and then developed severe cardiac arrhythmias is reported. A serious systemic toxic effect on cardiac rhythm from cutaneously applied phenol occurred in this case.

  16. Early and late arrhythmogenic effects of doxorubicin.

    PubMed

    Kilickap, Saadettin; Barista, Ibrahim; Akgul, Ebru; Aytemir, Kudret; Aksoy, Sercan; Tekuzman, Gulten

    2007-03-01

    To determine the incidence of early and late arrhythmogenic effects of doxorubicin-containing chemotherapy regimens. A prospective study including 29 patients who were treated with doxorubicin-containing regimens. Cardiac evaluation was based on 24-hour electrocardiographic monitorization (Holter), which was performed during the first cycle of doxorubicin-containing regimens, as well as after the last cycle of chemotherapy. The mean age of the patients was 45.8 +/- 15.1 (range 18-69). Holter records obtained during the first cycle of treatment revealed varying arrhythmias in 19 patients (65.5%) and in 18 (62.1%) patients after completion of therapy. One patient presented with syncope and both Mobitz Type 2 atrioventricular block and complete atrioventricular block were demonstrated. The patient subsequently underwent permanent pacemaker implantation. Doxorubicin may result in arrhythmias both in early and late periods of treatment. These arrhythmias are rarely life threatening.

  17. Hyperkalaemia, cardiac arrhythmias, and cerebral lesions in high risk neonates.

    PubMed Central

    Shortland, D; Trounce, J Q; Levene, M I

    1987-01-01

    The case notes of 20 infants with hyperkalaemia (defined as two successive serum potassium measurements of greater than 7.5 mmol/l) were reviewed. The incidence of hyperkalaemia was also looked at in an unselected population of 200 low birthweight infants. The mean gestational age of the 20 affected infants was 29 weeks and the mean birth weight 1235 g. The incidence of hyperkalemia in the cohort of 200 infants weighing less than 1500 g at birth was 3.5%. Hyperkalaemia was associated with a high incidence of cardiac arrhythmia (60%), impaired renal function (50%), and changes on cerebral ultrasonography (88%). Hyperkalaemia responds slowly to conventional treatment with dextrose, insulin, and exchange resins. There is a close temporal relation in some infants between hyperkalaemia and cardiac arrhythmias and periventricular leukomalacia, suggesting a causal association. PMID:3688918

  18. Cardiovascular manifestations of substance abuse: part 2: alcohol, amphetamines, heroin, cannabis, and caffeine.

    PubMed

    Frishman, William H; Del Vecchio, Alexander; Sanal, Shirin; Ismail, Anjum

    2003-01-01

    The abuse of alcohol is associated with chronic cardiomyopathy, hypertension, and arrhythmia. Abstinence or using alcohol in moderation can reverse these cardiovascular problems. Alcohol is also distinguished among the substances of abuse by having possible protective effects against coronary artery disease and stroke when used in moderate amounts. Amphetamines (eg, speed, ice, ecstasy) have many of the cardiovascular toxicities seen with cocaine, including acute and chronic cardiovascular diseases. Heroin and other opiates can cause arrhythmias and noncardiac pulmonary edema, and may reduce cardiac output. Cardiovascular problems are less common with cannabis (marijuana) than with opiates, but major cognitive disorders may be seen with its chronic use. It is still controversial whether caffeine can cause hypertension and coronary artery disease, and questions have been raised about its safety in patients with heart failure and arrhythmia.

  19. Spatial nonuniformity of excitation-contraction coupling causes arrhythmogenic Ca2+ waves in rat cardiac muscle.

    PubMed

    Wakayama, Yuji; Miura, Masahito; Stuyvers, Bruno D; Boyden, Penelope A; ter Keurs, Henk E D J

    2005-06-24

    Ca2+ waves underlying triggered propagated contractions (TPCs) are initiated in damaged regions in cardiac muscle and cause arrhythmias. We studied Ca2+ waves underlying TPCs in rat cardiac trabeculae under experimental conditions that simulate the functional nonuniformity caused by local mechanical or ischemic local damage of myocardium. A mechanical discontinuity along the trabeculae was created by exposing the preparation to a small jet of solution with a composition that reduces excitation-contraction coupling (ECC) in myocytes within that segment. The jet solution contained either caffeine (5 mmol/L), 2,3-butanedione monoxime (BDM; 20 mmol/L), or low Ca2+ concentration ([Ca2+]; 0.2 mmol/L). Force was measured with a silicon strain gauge and sarcomere length with laser diffraction techniques in 15 trabeculae. Simultaneously, [Ca2+]i was measured locally using epifluorescence of Fura-2. The jet of solution was applied perpendicularly to a small muscle region (200 to 300 microm) at constant flow. When the jet contained caffeine, BDM, or low [Ca2+], during the stimulated twitch, muscle-twitch force decreased and the sarcomeres in the exposed segment were stretched by shortening normal regions outside the jet. Typical protocols for TPC induction (7.5 s-2.5 Hz stimulus trains at 23 degrees C; [Ca2+]o=2.0 mmol/L) reproducibly generated Ca2+ waves that arose from the border between shortening and stretched regions. Such Ca2+ waves started during force-relaxation of the last stimulated twitch of the train and propagated (0.2 to 2.8 mm/sec) into segments both inside and outside of the jet. Arrhythmias, in the form of nondriven rhythmic activity, were induced when the amplitude of the Ca2+-wave was increased by raising [Ca2+]o. Arrhythmias disappeared rapidly when uniformity of ECC throughout the muscle was restored by turning the jet off. These results show, for the first time, that nonuniform ECC can cause Ca2+ waves underlying TPCs and suggest that Ca2+ dissociated from myofilaments plays an important role in the initiation of Ca2+ waves.

  20. Wholly Patient-tailored Ablation of Atrial Fibrillation Guided by Spatio-Temporal Dispersion of Electrograms in the Absence of Pulmonary Veins Isolation

    PubMed Central

    Seitz, Julien; Bars, Clément; Théodore, Guillaume; Beurtheret, Sylvain; Lellouche, Nicolas; Bremondy, Michel; Ferracci, Ange; Faure, Jacques; Penaranda, Guillaume; Yamazaki, Masatoshi; Avula, Uma Mahesh R.; Curel, Laurence; Siame, Sabrina; Berenfeld, Omer; Pisapia, André; Kalifa, Jérôme

    2017-01-01

    Background The use of intra-cardiac electrograms to guide atrial fibrillation (AF) ablation has yielded conflicting results. We evaluated an electrogram marker of AF drivers: the clustering of electrograms exhibiting spatio-temporal dispersion — regardless of whether such electrograms were fractionated or not. Objective To evaluate the usefulness of spatio-temporal dispersion, a visually recognizable electric footprint of AF drivers, for the ablation of all forms of AF. Methods We prospectively enrolled 105 patients admitted for AF ablation. AF was sequentially mapped in both atria with a 20-pole PentaRay catheter. We tagged and ablated only regions displaying electrogram dispersion during AF. Results were compared to a validation set in which a conventional ablation approach was used (pulmonary vein isolation/stepwise approach). To establish the mechanism underlying spatio-temporal dispersion of AF electrograms, we conducted realistic numerical simulations of AF drivers in a 2-dimensional model and optical mapping of ovine atrial scar-related AF. Results Ablation at dispersion areas terminated AF in 95%. After ablation of 17±10% of the left atrial surface and 18 months of follow-up, the atrial arrhythmia recurrence rate was 15% after 1.4±0.5 procedure/patient vs 41% in the validation set after 1.5±0.5 procedure/patient (arrhythmia free-survival rates: 85% vs 59%, log rank P<0.001). In comparison with the validation set, radiofrequency times (49 ± 21 minutes vs 85 ± 34.5 minutes, p=0.001) and procedure times (168 ± 42 minutes vs. 230 ± 67 minutes, p<.0001) were shorter. In simulations and optical mapping experiments, virtual PentaRay recordings demonstrated that electrogram dispersion is mostly recorded in the vicinity of a driver. Conclusions The clustering of intra-cardiac electrograms exhibiting spatio-temporal dispersion is indicative of AF drivers. Their ablation allows for a non-extensive and patient-tailored approach to AF ablation. Clinical trial.gov number: NCT02093949 PMID:28104073

  1. [Antifibrillatory activity of anti-arrhythmia agents in maximally high ligation of the coronary artery and its reperfusion in cats].

    PubMed

    Storozhuk, B G

    1985-01-01

    Experiments on anesthesized cats were performed to study antifibrillatory action of the basic antiarrhythmic remedies and a new Soviet drug, phenicaberan. It was established that phenicaberan and lidocaine compare very favourably with other drugs under study as regards the antifibrillatory effect. For that reason these drugs can be recommended for use in the prophylaxis of fatal arrhythmias.

  2. The influence of motor activity on the development of cardiac arrhythmias during experimental emotional stress

    NASA Technical Reports Server (NTRS)

    Ulyaninskiy, L. S.; Urmancheyeva, T. G.; Stepanyan, Y. P.; Fufacheva, A. A.; Gritsak, A. V.; Kuznetsova, B. A.; Kvitka, A. A.

    1982-01-01

    Experimental emotional stress which can produce various disorders of cardiac rhythm: sinus tachycardia, atrial fibrillation, ventricular, extrasystoles and paroxysmal ventricular tachysystoles was studied. In these conditions the adrenalin content in the blood and myocardium is increased 3 to 4 times. It is found that moderate motor activity leads to a relative decrease of adrenalin in the myocardium and arrest of cardiac arrhythmias.

  3. LiteNet: Lightweight Neural Network for Detecting Arrhythmias at Resource-Constrained Mobile Devices.

    PubMed

    He, Ziyang; Zhang, Xiaoqing; Cao, Yangjie; Liu, Zhi; Zhang, Bo; Wang, Xiaoyan

    2018-04-17

    By running applications and services closer to the user, edge processing provides many advantages, such as short response time and reduced network traffic. Deep-learning based algorithms provide significantly better performances than traditional algorithms in many fields but demand more resources, such as higher computational power and more memory. Hence, designing deep learning algorithms that are more suitable for resource-constrained mobile devices is vital. In this paper, we build a lightweight neural network, termed LiteNet which uses a deep learning algorithm design to diagnose arrhythmias, as an example to show how we design deep learning schemes for resource-constrained mobile devices. Compare to other deep learning models with an equivalent accuracy, LiteNet has several advantages. It requires less memory, incurs lower computational cost, and is more feasible for deployment on resource-constrained mobile devices. It can be trained faster than other neural network algorithms and requires less communication across different processing units during distributed training. It uses filters of heterogeneous size in a convolutional layer, which contributes to the generation of various feature maps. The algorithm was tested using the MIT-BIH electrocardiogram (ECG) arrhythmia database; the results showed that LiteNet outperforms comparable schemes in diagnosing arrhythmias, and in its feasibility for use at the mobile devices.

  4. Modelling the heart as a communication system.

    PubMed

    Ashikaga, Hiroshi; Aguilar-Rodríguez, José; Gorsky, Shai; Lusczek, Elizabeth; Marquitti, Flávia Maria Darcie; Thompson, Brian; Wu, Degang; Garland, Joshua

    2015-04-06

    Electrical communication between cardiomyocytes can be perturbed during arrhythmia, but these perturbations are not captured by conventional electrocardiographic metrics. We developed a theoretical framework to quantify electrical communication using information theory metrics in two-dimensional cell lattice models of cardiac excitation propagation. The time series generated by each cell was coarse-grained to 1 when excited or 0 when resting. The Shannon entropy for each cell was calculated from the time series during four clinically important heart rhythms: normal heartbeat, anatomical reentry, spiral reentry and multiple reentry. We also used mutual information to perform spatial profiling of communication during these cardiac arrhythmias. We found that information sharing between cells was spatially heterogeneous. In addition, cardiac arrhythmia significantly impacted information sharing within the heart. Entropy localized the path of the drifting core of spiral reentry, which could be an optimal target of therapeutic ablation. We conclude that information theory metrics can quantitatively assess electrical communication among cardiomyocytes. The traditional concept of the heart as a functional syncytium sharing electrical information cannot predict altered entropy and information sharing during complex arrhythmia. Information theory metrics may find clinical application in the identification of rhythm-specific treatments which are currently unmet by traditional electrocardiographic techniques. © 2015 The Author(s) Published by the Royal Society. All rights reserved.

  5. An arrhythmia classification algorithm using a dedicated wavelet adapted to different subjects.

    PubMed

    Kim, Jinkwon; Min, Se Dong; Lee, Myoungho

    2011-06-27

    Numerous studies have been conducted regarding a heartbeat classification algorithm over the past several decades. However, many algorithms have also been studied to acquire robust performance, as biosignals have a large amount of variation among individuals. Various methods have been proposed to reduce the differences coming from personal characteristics, but these expand the differences caused by arrhythmia. In this paper, an arrhythmia classification algorithm using a dedicated wavelet adapted to individual subjects is proposed. We reduced the performance variation using dedicated wavelets, as in the ECG morphologies of the subjects. The proposed algorithm utilizes morphological filtering and a continuous wavelet transform with a dedicated wavelet. A principal component analysis and linear discriminant analysis were utilized to compress the morphological data transformed by the dedicated wavelets. An extreme learning machine was used as a classifier in the proposed algorithm. A performance evaluation was conducted with the MIT-BIH arrhythmia database. The results showed a high sensitivity of 97.51%, specificity of 85.07%, accuracy of 97.94%, and a positive predictive value of 97.26%. The proposed algorithm achieves better accuracy than other state-of-the-art algorithms with no intrasubject between the training and evaluation datasets. And it significantly reduces the amount of intervention needed by physicians.

  6. An arrhythmia classification algorithm using a dedicated wavelet adapted to different subjects

    PubMed Central

    2011-01-01

    Background Numerous studies have been conducted regarding a heartbeat classification algorithm over the past several decades. However, many algorithms have also been studied to acquire robust performance, as biosignals have a large amount of variation among individuals. Various methods have been proposed to reduce the differences coming from personal characteristics, but these expand the differences caused by arrhythmia. Methods In this paper, an arrhythmia classification algorithm using a dedicated wavelet adapted to individual subjects is proposed. We reduced the performance variation using dedicated wavelets, as in the ECG morphologies of the subjects. The proposed algorithm utilizes morphological filtering and a continuous wavelet transform with a dedicated wavelet. A principal component analysis and linear discriminant analysis were utilized to compress the morphological data transformed by the dedicated wavelets. An extreme learning machine was used as a classifier in the proposed algorithm. Results A performance evaluation was conducted with the MIT-BIH arrhythmia database. The results showed a high sensitivity of 97.51%, specificity of 85.07%, accuracy of 97.94%, and a positive predictive value of 97.26%. Conclusions The proposed algorithm achieves better accuracy than other state-of-the-art algorithms with no intrasubject between the training and evaluation datasets. And it significantly reduces the amount of intervention needed by physicians. PMID:21707989

  7. Non-contact arrhythmia assessment in natural settings: a step toward preventive cardiac care

    NASA Astrophysics Data System (ADS)

    Amelard, Robert; Hughson, Richard L.; Clausi, David A.; Wong, Alexander

    2017-02-01

    Cardiovascular disease is a major contributor to US morbidity. Taking preventive action can greatly reduce or eliminate the impact on quality of life. However, many issues often go undetected until the patient presents a physical symptom. Non-intrusive continuous cardiovascular monitoring systems may make detecting and monitoring abnormalities earlier feasible. One candidate system is photoplethysmographic imaging (PPGI), which is able to assess arterial blood pulse characteristics in one or multiple individuals remotely from a distance. In this case study, we showed that PPGI can be used to detect cardiac arrhythmia that would otherwise require contact-based monitoring techniques. Using a novel system, coded hemodynamic imaging (CHI), strong temporal blood pulse waveform signals were extracted at a distance of 1.5 m from the participant using 850-1000 nm diffuse illumination for deep tissue penetration. Data were recorded at a sampling rate of 60 Hz, providing a temporal resolution of 17 ms. The strong fidelity of the signal allowed for both temporal and spectral assessment of abnormal blood pulse waveforms, ultimately to detect the onset of abnormal cardiac events. Data from a participant with arrhythmia was analyzed and compared against normal blood pulse waveform data to validate CHI's ability to assess cardiac arrhythmia. Results indicate that CHI can be used as a non-intrusive continuous cardiac monitoring system.

  8. Gout and arrhythmias: In search for causation beyond association.

    PubMed

    Giannopoulos, Georgios; Angelidis, Christos; Deftereos, Spyridon

    2018-06-13

    Gout is a systemic disease, characterized by the formation and deposition of crystals in tissues (mainly in and around the joints) of individuals with elevated serum uric acid levels. Lately, a considerable number of reports relating elevated uric acid and/or gout with rhythm disorders, such as atrial fibrillation, have been published. This review summarizes evidence linking common arrhythmias and hyperuricemia/gout and discusses questions or controversies that surround it. Overall, existing evidence may not be overwhelming, but strongly suggests a positive correlation between uric acid levels and common rhythm disorders. Needless to say that such a link - as a univariate association between the two - is to be expected, given the extensive overlap of risk factors and comorbidities of hyperuricemia/gout and arrhythmias. However, the observed associations seem to persist - in most studies - after extensive adjustment for potential confounders. Still, multivariable analyses of epidemiologically collected data cannot substitute for proof coming from basic and clinical studies. There is obviously a need for further basic research to establish a causal relationship between uric acid effects and arrhythmias, as well as translational studies and clinical trials to investigate the therapeutic implications of such a relationship. Simply put, we are fairly certain that there is association, but proof of causation is what we are still in want of. Copyright © 2018. Published by Elsevier Inc.

  9. Hydroxyl radicals' production and ECG parameters during ischemia and reperfusion in rat, guinea pig and rabbit isolated heart.

    PubMed

    Paulova, Hana; Stracina, Tibor; Jarkovsky, Jiri; Novakova, Marie; Taborska, Eva

    2013-06-01

    Ischemic and reperfusion injury is a serious condition related to numerous biochemical and electrical abnormalities of the myocardium. It has been repeatedly studied in various animal models. In this study, the production of hydroxyl radicals and electrophysiological parameters were compared in three species. Rat, guinea pig and rabbit isolated hearts were perfused according to Langendorff under strictly identical conditions. The heart rate and arrhythmia were monitored during ischemia and reperfusion periods at defined time intervals; the production of hydroxyl radical was determined by HPLC as 2.5-dihydroxybenzoic acid (2.5-DHBA) formed by salicylic acid hydroxylation. Relationship between arrhythmias and production of 2.5-DHBA was studied. The inter-species differences were observed in timing of arrhythmias onset and their severity, and in the production of 2.5-DHBA in both ischemia and reperfusion. The most considerable changes were observed in rats, where arrhythmias appeared early and with highest severity during ischemia on one side and the regular rhythm was restored early and completely during reperfusion. The corresponding changes in the production of 2.5-DHBA were observed. It can be concluded that rat isolated heart is the most suitable model for evaluation of ischemia/reperfusion injury under given experimental conditions.

  10. LiteNet: Lightweight Neural Network for Detecting Arrhythmias at Resource-Constrained Mobile Devices

    PubMed Central

    Zhang, Xiaoqing; Cao, Yangjie; Liu, Zhi; Zhang, Bo; Wang, Xiaoyan

    2018-01-01

    By running applications and services closer to the user, edge processing provides many advantages, such as short response time and reduced network traffic. Deep-learning based algorithms provide significantly better performances than traditional algorithms in many fields but demand more resources, such as higher computational power and more memory. Hence, designing deep learning algorithms that are more suitable for resource-constrained mobile devices is vital. In this paper, we build a lightweight neural network, termed LiteNet which uses a deep learning algorithm design to diagnose arrhythmias, as an example to show how we design deep learning schemes for resource-constrained mobile devices. Compare to other deep learning models with an equivalent accuracy, LiteNet has several advantages. It requires less memory, incurs lower computational cost, and is more feasible for deployment on resource-constrained mobile devices. It can be trained faster than other neural network algorithms and requires less communication across different processing units during distributed training. It uses filters of heterogeneous size in a convolutional layer, which contributes to the generation of various feature maps. The algorithm was tested using the MIT-BIH electrocardiogram (ECG) arrhythmia database; the results showed that LiteNet outperforms comparable schemes in diagnosing arrhythmias, and in its feasibility for use at the mobile devices. PMID:29673171

  11. Recurrent Ventricular Tachycardia in Medium-Chain Acyl-Coenzyme A Dehydrogenase Deficiency.

    PubMed

    Bala, P; Ferdinandusse, S; Olpin, S E; Chetcuti, P; Morris, A A M

    2016-01-01

    We report a baby with medium-chain acyl-coenzyme A dehydrogenase (MCAD) deficiency who presented on day 2 with poor feeding and lethargy. She was floppy with hypoglycaemia (1.8 mmol/l) and hyperammonaemia (182 μmol/l). Despite correction of these and a continuous intravenous infusion of glucose at 4.5-6.2 mg/kg/min, she developed generalised tonic clonic seizures on day 3. She also suffered two episodes of pulseless ventricular tachycardia, from which she was resuscitated successfully. Unfortunately, she died on day 5, following a third episode of pulseless ventricular tachycardia. Arrhythmias are generally thought to be rarer in MCAD deficiency than in disorders of long-chain fatty acid oxidation. This is, however, the sixth report of ventricular tachyarrhythmias in MCAD deficiency. Five of these involved neonates and it may be that patients with MCAD deficiency are particularly prone to ventricular arrhythmias in the newborn period. Three of the patients (including ours) had normal blood glucose concentrations at the time of the arrhythmias and had been receiving intravenous glucose for many hours. These cases suggest that arrhythmias can be induced by medium-chain acylcarnitines or other metabolites accumulating in MCAD deficiency. Ventricular tachyarrhythmias can occur in MCAD deficiency, especially in neonates.

  12. [Galectin-3 in Patients With Paroxysmal and Persistent Atrial Fibrillation and Metabolic Syndrome].

    PubMed

    A, V A; Zaslavskaya, E L; Soboleva, A V; Baranova, E I; Listopad, O V; Nifontov, S E; Nrady, A O; Shlyakhto, E V

    2016-06-01

    To evaluate serum galectin 3 and to determine the potential clinical value of this parameter in patients with atrial fibrillation - AF (paroxysmal and persistent) and metabolic syndrome (MS). We examined 100 patients with MS (50 with paroxysmal or persistent AF and 50 without arrhythmia) and 50 healthy persons. Serum galectin 3 measured by ELISA method, ECHO cardiography was performed to all examined persons. Galectin 3 in patients with MS and AF was higher, than in patients with MS without arrhythmia and much more higher than galectin 3 in healthy persons 0,72 (0,44;1,36), 0,44 (0,42;1,22) and 0,32 (0,28;0,42) ng/ml (<0,01). In patients with persistent AF levels of galectin 3 is higher than in patients with paroxysmal AF. Positive correlation between the levels of galectin 3 and duration arrhythmia was revealed (r=0,301; p<0,01). Higher level of galectin 3 was revealed in patients with frequent paroxysms of AF and ineffective antiarrhythmic therapy. Marker of myocardial fibrosis serum galectin 3 in patients with atrial fibrillation and metabolic syndrome is higher than in patients with the metabolic syndrome, without this arrhythmia and higher than in healthy controls. In patients with persistent AF level of galectin 3 was higher than in patients with paroxysmal AF.

  13. Simulations and Games as Chaordic Learning Contexts

    ERIC Educational Resources Information Center

    Leigh, Elyssebeth; Spindler, Laraine

    2004-01-01

    Effective facilitation of experiential learning involves an array of knowledge and skills. Educators who facilitate open simulations--one form of experiential learning--benefit from having relevant theoretical frameworks to sustain an appropriate balance between being directive and supportive of their participants' freedom to learn. This ongoing…

  14. Benchmarking electrophysiological models of human atrial myocytes

    PubMed Central

    Wilhelms, Mathias; Hettmann, Hanne; Maleckar, Mary M.; Koivumäki, Jussi T.; Dössel, Olaf; Seemann, Gunnar

    2013-01-01

    Mathematical modeling of cardiac electrophysiology is an insightful method to investigate the underlying mechanisms responsible for arrhythmias such as atrial fibrillation (AF). In past years, five models of human atrial electrophysiology with different formulations of ionic currents, and consequently diverging properties, have been published. The aim of this work is to give an overview of strengths and weaknesses of these models depending on the purpose and the general requirements of simulations. Therefore, these models were systematically benchmarked with respect to general mathematical properties and their ability to reproduce certain electrophysiological phenomena, such as action potential (AP) alternans. To assess the models' ability to replicate modified properties of human myocytes and tissue in cardiac disease, electrical remodeling in chronic atrial fibrillation (cAF) was chosen as test case. The healthy and remodeled model variants were compared with experimental results in single-cell, 1D and 2D tissue simulations to investigate AP and restitution properties, as well as the initiation of reentrant circuits. PMID:23316167

  15. Theoretical foundations of learning through simulation.

    PubMed

    Zigmont, Jason J; Kappus, Liana J; Sudikoff, Stephanie N

    2011-04-01

    Health care simulation is a powerful educational tool to help facilitate learning for clinicians and change their practice to improve patient outcomes and safety. To promote effective life-long learning through simulation, the educator needs to consider individuals, their experiences, and their environments. Effective education of adults through simulation requires a sound understanding of both adult learning theory and experiential learning. This review article provides a framework for developing and facilitating simulation courses, founded upon empiric and theoretic research in adult and experiential learning. Specifically, this article provides a theoretic foundation for using simulation to change practice to improve patient outcomes and safety. Copyright © 2011 Elsevier Inc. All rights reserved.

  16. Qualitative evaluation of a standardized patient clinical simulation for nurse practitioner and pharmacy students.

    PubMed

    Koo, Laura; Layson-Wolf, Cherokee; Brandt, Nicole; Hammersla, Margaret; Idzik, Shannon; Rocafort, P Tim; Tran, Deanna; Wilkerson, R Gentry; Windemuth, Brenda

    2014-11-01

    This article describes a qualitative evaluation of an interprofessional educational experience for nurse practitioner and pharmacy students using standardized patients and physicians role-playing physicians in clinical scenarios. This experience included the development of two clinical scenarios; training of standardized patients, providers, and faculty facilitators; pre-briefing preparation; partial facilitator prompting simulations; and facilitated debriefings. Forty-six students participated in the formative simulation. Small groups of students and faculty facilitators worked through two clinical scenarios that were based on the expected emergence of the patient-centered medical homes. The scenarios incorporated different interprofessional communication modes, including in-person, telephonic, and video-conferencing. Time-in/time-out debriefings were incorporated to provide guidance to students about how to engage in interprofessional collaboration. After completion of the scenarios, facilitated group debriefings allowed for reflection on communication strategies and roles. Immediately following the learning activity, 30 volunteer focus group participants provided comments anonymously in a semi-structured format. Conventional content analysis was used to identify overarching themes. Participants expressed improved understanding of individual roles, increased confidence, and a better sense of interprofessional support. The educational experience themes included the benefits of a realistic nature of the simulation and the need for improved student orientation to roles and expectations prior to the clinical simulations. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. ECG Holter monitor with alert system and mobile application

    NASA Astrophysics Data System (ADS)

    Teron, Abigail C.; Rivera, Pedro A.; Goenaga, Miguel A.

    2016-05-01

    This paper proposes a new approach on the Holter monitor by creating a portable Electrocardiogram (ECG) Holter monitor that will alert the user by detecting abnormal heart beats using a digital signal processing software. The alarm will be triggered when the patient experiences arrhythmias such as bradycardia and tachycardia. The equipment is simple, comfortable and small in size that fit in the hand. It can be used at any time and any moment by placing three leads to the person's chest which is connected to an electronic circuit. The ECG data will be transmitted via Bluetooth to the memory of a selected mobile phone using an application that will store the collected data for up to 24 hrs. The arrhythmia is identified by comparing the reference signals with the user's signal. The diagnostic results demonstrate that the ECG Holter monitor alerts the user when an arrhythmia is detected thru the Holter monitor and mobile application.

  18. Anti-arrhythmic activities of opioid agonists and antagonists and their stereoisomers.

    PubMed Central

    Sarne, Y.; Flitstein, A.; Oppenheimer, E.

    1991-01-01

    1. A series of opioid agonists, antagonists and their (+)-stereoisomers were tested for antiarrhythmic activity in the rat coronary artery occlusion model. 2. Naloxone (0.01-2 mg kg-1) significantly reduced the incidence and severity of cardiac arrhythmias, in accordance with previous published studies. 3. The non-opioid stereoisomer, (+)-naloxone, was equipotent with naloxone against occlusion-induced arrhythmia. 4. Similar non-stereospecific antiarrhythmic effects were induced by another opioid antagonist, Win 44,441-3 and its stereoisomer Win 44,441-2. 5. The opioid agonists, morphine and levorphanol, protected against occlusion-induced arrhythmia as did the opioid antagonists, and the (+)-stereoisomer, dextrorphan, was equipotent to levorphanol. 6. It is concluded that the antiarrhythmic effects of opioid drugs are not mediated by opioid receptors. A direct effect on ionic currents in cardiac muscle is suggested as the mechanism of opioid antiarrhythmic activity. PMID:1364840

  19. Electrocardiographic Presentation, Cardiac Arrhythmias, and Their Management in β-Thalassemia Major Patients.

    PubMed

    Russo, Vincenzo; Rago, Anna; Papa, Andrea Antonio; Nigro, Gerardo

    2016-07-01

    Beta-thalassemia major (β-TM) is a genetic hemoglobin disorder characterized by an absent synthesis of globin chains that are essential for hemoglobin formation, causing chronic hemolytic anemia. Clinical management of thalassemia major consists in regular long-life red blood cell transfusions and iron chelation therapy to remove iron introduced in excess with transfusions. Iron deposition in combination with inflammatory and immunogenic factors is involved in the pathophysiology of cardiac dysfunction in these patients. Heart failure and arrhythmias, caused by myocardial siderosis, are the most important life-limiting complications of iron overload in beta-thalassemia patients. Cardiac complications are responsible for 71% of global death in the beta-thalassemia major patients. The aim of this review was to describe the most frequent electrocardiographic abnormalities and arrhythmias observed in β-TM patients, analyzing their prognostic impact and current treatment strategies. © 2016 Wiley Periodicals, Inc.

  20. Determining conduction patterns on a sparse electrode grid: Implications for the analysis of clinical arrhythmias

    NASA Astrophysics Data System (ADS)

    Vidmar, David; Narayan, Sanjiv M.; Krummen, David E.; Rappel, Wouter-Jan

    2016-11-01

    We present a general method of utilizing bioelectric recordings from a spatially sparse electrode grid to compute a dynamic vector field describing the underlying propagation of electrical activity. This vector field, termed the wave-front flow field, permits quantitative analysis of the magnitude of rotational activity (vorticity) and focal activity (divergence) at each spatial point. We apply this method to signals recorded during arrhythmias in human atria and ventricles using a multipolar contact catheter and show that the flow fields correlate with corresponding activation maps. Further, regions of elevated vorticity and divergence correspond to sites identified as clinically significant rotors and focal sources where therapeutic intervention can be effective. These flow fields can provide quantitative insights into the dynamics of normal and abnormal conduction in humans and could potentially be used to enhance therapies for cardiac arrhythmias.

  1. Atrial flutter after surgical maze: incidence, diagnosis, and management.

    PubMed

    Dresen, William; Mason, Pamela K

    2016-01-01

    The prevalence of atrial fibrillation is increasing and surgical ablation is becoming more common, both as a stand-alone procedure and when performed concomitantly with other cardiac surgery. Although surgical ablation is effective, with it unique challenges arise, including iatrogenic macroreentrant tachycardias that are often highly symptomatic and difficult to manage conservatively. Postsurgical ablation, localization of the arrhythmic circuit is difficult to determine using surface ECG alone because of alterations in the atrial myocardium, and multiple different pathways are often present. Most, however, localize to the left atrium, and percutaneous catheter ablation is emerging as an effective treatment modality. Patients with complex postoperative arrhythmias should be referred to a dedicated atrial fibrillation center when possible and symptomatic arrhythmias mapped and ablated. Knowledge of the previously performed surgical lesion set is of vital importance in understanding the mechanism of the arrhythmia and increasing procedural success rates. http://links.lww.com/HCO/A31.

  2. Surgical treatment for ectopic atrial tachycardia.

    PubMed

    Graffigna, A; Vigano, M; Pagani, F; Salerno, G

    1992-08-01

    Atrial tachycardia is an infrequent but potentially dangerous arrhythmia which often determines cardiac enlargement. Surgical ablation of the arrhythmia is effective and safe, provided a careful atrial mapping is performed and the surgical technique is tailored to the individual focus location. Eight patients underwent surgical ablation of ectopic atrial tachycardia between 1977 and 1990. Different techniques were adopted for each patient according to the anatomical location of the focus and possibly associated arrhythmias. Whenever possible, a closed heart procedure was chosen. In 1 patient a double focal origin was found and treated by separate procedures. In 1 patient with ostium secundum atrial septal defect and atrial flutter, surgical isolation of the right appendage and the ectopic focus was performed. In all patients ectopic atrial tachycardia was ablated with maintenance of the sinoatrial and atrioventricular nodal function as well as internodal conduction. In follow-up up to December 1991, no recurrency was recorded.

  3. Patient-centred care of patients with ventricular arrhythmias and risk of sudden cardiac death: What do the 2015 European Society of Cardiology guidelines add?

    PubMed

    Norekvål, Tone M; Kirchhof, Paulus; Fitzsimons, Donna

    2017-10-01

    Nurses and allied professionals are at the forefront of care delivery in patients with arrythmogenic risk and have a responsibility to deliver care that is focused on their individual needs. The 2015 European Society of Cardiology guideline on prevention of ventricular arrhythmia and sudden cardiac death heralds a step-change in patient and family focus and interdisciplinary involvement. This development reflects a recognition within the European Society of Cardiology that chronic care of patients with cardiovascular conditions can be improved by involving all stakeholders, making use of multidisciplinary interventions, and placing the patient at the centre of the care process. In this article, taskforce contributors discuss the latest evidence and highlight some of the most pertinent issues for nurses involved in patient-centred care of patients and families with ventricular arrhythmias and/or risk of sudden death.

  4. Coi-wiz: An interactive computer wizard for analyzing cardiac optical signals.

    PubMed

    Yuan, Xiaojing; Uyanik, Ilyas; Situ, Ning; Xi, Yutao; Cheng, Jie

    2009-01-01

    A number of revolutionary techniques have been developed for cardiac electrophysiology research to better study the various arrhythmia mechanisms that can enhance ablating strategies for cardiac arrhythmias. Once the three-dimensional high resolution cardiac optical imaging data is acquired, it is time consuming to manually go through them and try to identify the patterns associated with various arrhythmia symptoms. In this paper, we present an interactive computer wizard that helps cardiac electrophysiology researchers to visualize and analyze the high resolution cardiac optical imaging data. The wizard provides a file interface that accommodates different file formats. A series of analysis algorithms output waveforms, activation and action potential maps after spatial and temporal filtering, velocity field and heterogeneity measure. The interactive GUI allows the researcher to identify the region of interest in both the spatial and temporal domain, thus enabling them to study different heart chamber at their choice.

  5. A complete heart block in a young male: a case report and review of literature of cardiac sarcoidosis.

    PubMed

    Patel, Brijesh; Shah, Mahek; Gelaye, Alehegn; Dusaj, Raman

    2017-01-01

    Cardiac sarcoidosis is one of the uncommon causes of heart failure. Generally, it presents in the form of varying clinical manifestations ranging from asymptomatic to fatal arrhythmias such as ventricular tachycardia and complete heart block. It is difficult to make a diagnosis strictly based on clinical grounds. However, in the setting of extracardiac sarcoidosis and patients presenting with advanced heart block or ventricular arrhythmia, direct cardiac involvement should be suspected. The definitive diagnosis of cardiac sarcoidosis can be made from endomyocardial biopsy, but it is falling out of favor due to patchy myocardial involvement, considerable procedure-related risks, and advancement in additional imaging modalities. Once cardiac sarcoidosis has been diagnosed, management of the disease remains challenging. Steroids are considered the mainstay of therapy, and implantable cardioverter defibrillator therapy can be considered in a selected group of patients at greater risk for malignant ventricular arrhythmias.

  6. AANA Journal Course: update for nurse anesthetists. Arrhythmia management devices and electromagnetic interference.

    PubMed

    Mattingly, Emily

    2005-04-01

    The technological complexity of implantable arrhythmia management devices, specifically pacemakers and defibrillators, has increased dramatically since their introduction only a few decades ago. Patients with such devices are encountered much more frequently in hospitals and surgery centers, yet anesthesia provider knowledge of safe and proper management is often incomplete. Anesthesia textbooks and references may provide only short paragraphs on arrhythmia management devices that do not address important perioperative management strategies for this ever-growing patient population. It is no longer satisfactory to simply place a magnet over an implanted device during surgery and assume that this action protects the patient from harm due to electromagnetic interference from inappropriate device function. This AANA Journal course serves as a concise review of basic device function, the sources and effects of electromagnetic interference in the operative setting, and patient management recommendations from current literature.

  7. [Prevention of ventricular fibrillation with the aid of protopine in animal experiments].

    PubMed

    Burtsev, V N; Dormidontov, E N; Saliaev, V N

    1978-04-01

    The anti-arrhythmic activity of protopin, quinidine and novocainamide infused intravenously as a preventive and relieving measure was studied in acute experiments on rats with calcium chloride and aconitic arrhythmia. In myocardial fibrillation induced by calcium chloride the contents in the rat heart of adrenalin, noradrenaline, dopa and dopamine were studied by spectrofluorimetry before and after the use of protopin. It was established that in the size of its minimum effective doses which arrest or prevent calcium chloride and aconitic arrhythmias in rats protopin is two to three times more potent than quinidine and novocainamide. The mechanism of the anti-arrhythmic effect of protopin in calcium chloride and aconitic arrhythmias is complex and is due to the suppression of the foci of heterotopic stimulation, decrease in excitability of the myocardial cells and normalization of the catecholamine content in the myocardium.

  8. Benchmarking heart rate variability toolboxes.

    PubMed

    Vest, Adriana N; Li, Qiao; Liu, Chengyu; Nemati, Shamim; Shah, Amit; Clifford, Gari D

    Heart rate variability (HRV) metrics hold promise as potential indicators for autonomic function, prediction of adverse cardiovascular outcomes, psychophysiological status, and general wellness. Although the investigation of HRV has been prevalent for several decades, the methods used for preprocessing, windowing, and choosing appropriate parameters lack consensus among academic and clinical investigators. A comprehensive and open-source modular program is presented for calculating HRV implemented in Matlab with evidence-based algorithms and output formats. We compare our software with another widely used HRV toolbox written in C and available through PhysioNet.org. Our findings show substantially similar results when using high quality electrocardiograms (ECG) free from arrhythmias. Our software shows equivalent performance alongside an established predecessor and includes validated tools for performing preprocessing, signal quality, and arrhythmia detection to help provide standardization and repeatability in the field, leading to fewer errors in the presence of noise or arrhythmias. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. New Methods for the Analysis of Heartbeat Behavior in Risk Stratification

    PubMed Central

    Glass, Leon; Lerma, Claudia; Shrier, Alvin

    2011-01-01

    Developing better methods for risk stratification for tachyarrhythmic sudden cardiac remains a major challenge for physicians and scientists. Since the transition from sinus rhythm to ventricular tachycardia/fibrillation happens by different mechanisms in different people, it is unrealistic to think that a single measure will be adequate to provide a good index for risk stratification. We analyze the dynamical properties of ventricular premature complexes over 24 h in an effort to understand the underlying mechanisms of ventricular arrhythmias and to better understand the arrhythmias that occur in individual patients. Two dimensional density plots, called heartprints, correlate characteristic features of the dynamics of premature ventricular complexes and the sinus rate. Heartprints show distinctive characteristics in individual patients. Based on a better understanding of the natures of transitions from sinus rhythm to sudden cardiac and the mechanisms of arrhythmia prior to cardiac arrest, it should be possible to develop better methods for risk stratification. PMID:22144963

  10. 3D optical digitation applied to orthodontics: analysis of unilateral cleft lip and palate in newborn infants

    NASA Astrophysics Data System (ADS)

    Canal, Fernando; Garcia-Mateos, Jorge; Rodriguez-Larena, Jorge; Rivera, Alejandro; Aparicio, E.

    2000-12-01

    Medical therapeutic applications using lasers involves understanding the light tissue interaction, in particular the rate ofphotochemical and thermal reactions. Tissue is composed ofa mix ofturbid media. Light propagation in turbid media can be described by the so-called Equation of Radiative Transfer, an integro-differential equation where scattering, absorption and internal reflection are significant factors in determining the light distribution in tissue. The Equation of Radiative Transfer however can not commonly be solved analytically.' In order to visualize and simulate the effects of laser light on heart tissues (myocardium) in relation to the treatment of irregular heart rates or so called arrhythmias, a fast interactive computer program has been developed in Java.

  11. Simulated interprofessional education: an analysis of teaching and learning processes.

    PubMed

    van Soeren, Mary; Devlin-Cop, Sandra; Macmillan, Kathleen; Baker, Lindsay; Egan-Lee, Eileen; Reeves, Scott

    2011-11-01

    Simulated learning activities are increasingly being used in health professions and interprofessional education (IPE). Specifically, IPE programs are frequently adopting role-play simulations as a key learning approach. Despite this widespread adoption, there is little empirical evidence exploring the teaching and learning processes embedded within this type of simulation. This exploratory study provides insight into the nature of these processes through the use of qualitative methods. A total of 152 clinicians, 101 students and 9 facilitators representing a range of health professions, participated in video-recorded role-plays and debrief sessions. Videotapes were analyzed to explore emerging issues and themes related to teaching and learning processes related to this type of interprofessional simulated learning experience. In addition, three focus groups were conducted with a subset of participants to explore perceptions of their educational experiences. Five key themes emerged from the data analysis: enthusiasm and motivation, professional role assignment, scenario realism, facilitator style and background and team facilitation. Our findings suggest that program developers need to be mindful of these five themes when using role-plays in an interprofessional context and point to the importance of deliberate and skilled facilitation in meeting desired learning outcomes.

  12. Efficacy of Flecainide in the Treatment of Catecholaminergic Polymorphic Ventricular Tachycardia: A Randomized Clinical Trial.

    PubMed

    Kannankeril, Prince J; Moore, Jeremy P; Cerrone, Marina; Priori, Silvia G; Kertesz, Naomi J; Ro, Pamela S; Batra, Anjan S; Kaufman, Elizabeth S; Fairbrother, David L; Saarel, Elizabeth V; Etheridge, Susan P; Kanter, Ronald J; Carboni, Michael P; Dzurik, Matthew V; Fountain, Darlene; Chen, Heidi; Ely, E Wesley; Roden, Dan M; Knollmann, Bjorn C

    2017-07-01

    Catecholaminergic polymorphic ventricular tachycardia (CPVT) is a potentially lethal genetic arrhythmia syndrome characterized by polymorphic ventricular tachycardia with physical or emotional stress, for which current therapy with β-blockers is incompletely effective. Flecainide acetate directly suppresses sarcoplasmic reticulum calcium release-the cellular mechanism responsible for triggering ventricular arrhythmias in CPVT-but has never been assessed prospectively. To determine whether flecainide dosed to therapeutic levels and added to β-blocker therapy is superior to β-blocker therapy alone for the prevention of exercise-induced arrhythmias in CPVT. This investigator-initiated, multicenter, single-blind, placebo-controlled crossover clinical trial was conducted from December 19, 2011, through December 29, 2015, with a midtrial protocol change at 10 US sites. Patients with a clinical diagnosis of CPVT and an implantable cardioverter-defibrillator underwent a baseline exercise test while receiving maximally tolerated β-blocker therapy that was continued throughout the trial. Patients were then randomized to treatment A (flecainide or placebo) for 3 months, followed by exercise testing. After a 1-week washout period, patients crossed over to treatment B (placebo or flecainide) for 3 months, followed by exercise testing. Patients received oral flecainide or placebo twice daily, with the dosage guided by trough serum levels. The primary end point of ventricular arrhythmias during exercise was compared between the flecainide and placebo arms. Exercise tests were scored on an ordinal scale of worst ventricular arrhythmia observed (0 indicates no ectopy; 1, isolated premature ventricular beats; 2, bigeminy; 3, couplets; and 4, nonsustained ventricular tachycardia). Of 14 patients (7 males and 7 females; median age, 16 years [interquartile range, 15.0-22.5 years]) randomized, 13 completed the study. The median baseline exercise test score was 3.0 (range, 0-4), with no difference noted between the baseline and placebo (median, 2.5; range, 0-4) exercise scores. The median ventricular arrhythmia score during exercise was significantly reduced by flecainide (0 [range, 0-2] vs 2.5 [range, 0-4] for placebo; P < .01), with complete suppression observed in 11 of 13 patients (85%). Overall and serious adverse events did not differ between the flecainide and placebo arms. In this randomized clinical trial of patients with CPVT, flecainide plus β-blocker significantly reduced ventricular ectopy during exercise compared with placebo plus β-blocker and β-blocker alone. clinicaltrials.gov Identifier: NCT01117454.

  13. Effects of dexmedetomidine on heart arrhythmia prevention in off-pump coronary artery bypass surgery: A randomized clinical trial.

    PubMed

    Soltani, Ghasem; Jahanbakhsh, Saeed; Tashnizi, Mohammad Abbasi; Fathi, Mehdi; Amini, Shahram; Zirak, Nahid; Sheybani, Shima

    2017-10-01

    Arrhythmia occurring during and after surgery is one of the major complications in open-heart surgery. Dexmedetomidine is an intravenous alpha-2 agonist and very specific short-acting drug to protect the various organs against ischemic injuries and blood reflow. However, the effect of dexmedetomidine for preventing intraoperative heart arrhythmias has not been recognized. This study aimed to determine the effect of dexmedetomidine on the incidence rate of heart arrhythmias and anesthetic required in off-pump coronary artery bypass surgery. This randomized clinical trial was conducted on patients who were candidates for off-pump coronary artery bypass referring to Imam Reza Hospital of Mashhad, Iran, from July 2016 through January 2017. The patients were randomly assigned to two groups of intervention (infusion of 0.5 mcg/kg/h dexmedetomidine together with induction followed by infusion of 0.5 mcg/kg/h by the end of the surgery) or control (saline infusion). Mean arterial pressure (MAP) and heart rate (HR) were measured before induction, during surgery operation and ICU admission. Data were analyzed by SPSS version 18 using Chi Square and independent-samples t-test. A total of 76 patients with a mean age of 59.8 ± 8.2 years (in two groups of 38) were studied. The two groups had no statistically significant difference in terms of background variables. The MAP and HR values before induction, during surgery and ICU admission were significantly higher in the control group than in the intervention group (p=0.001). Out of the studied arrhythmias, the values of PAC (55.2% vs. 15.7%), PVC (81.5% vs. 21.0%), AF (26.3% vs. 7.8%), VTAC (21.0% vs. 2.6%) were significantly lower in dexmedetomidine group (p=0.001). It seems that dexmedetomidine administration during induction and surgery can cause significant reduction in most of the common arrhythmias in off-pump coronary bypass surgery. The use of dexmedetomidine maintains MAP and HR at significantly lower values, and changes compared to the control group as well as reduces the need for anesthetic compounds. The present study has been registered at the Iranian Registry of Clinical Trials (www.IRCT.IR) with a code of IRCT2016072413159N9 before starting the study. This study was fully sponsored by the Research Deputy at Mashhad University of Medical Sciences, Iran (grant number 941413).

  14. A modeling and simulation approach to characterize methadone QT prolongation using pooled data from five clinical trials in MMT patients.

    PubMed

    Florian, J; Garnett, C E; Nallani, S C; Rappaport, B A; Throckmorton, D C

    2012-04-01

    Pharmacokinetic (PK)-pharmacodynamic modeling and simulation were used to establish a link between methadone dose, concentrations, and Fridericia rate-corrected QT (QTcF) interval prolongation, and to identify a dose that was associated with increased risk of developing torsade de pointes. A linear relationship between concentration and QTcF described the data from five clinical trials in patients on methadone maintenance treatment (MMT). A previously published population PK model adequately described the concentration-time data, and this model was used for simulation. QTcF was increased by a mean (90% confidence interval (CI)) of 17 (12, 22) ms per 1,000 ng/ml of methadone. Based on this model, doses >120 mg/day would increase the QTcF interval by >20 ms. The model predicts that 1-3% of patients would have ΔQTcF >60 ms, and 0.3-2.0% of patients would have QTcF >500 ms at doses of 160-200 mg/day. Our predictions are consistent with available observational data and support the need for electrocardiogram (ECG) monitoring and arrhythmia risk factor assessment in patients receiving methadone doses >120 mg/day.

  15. Transcatheter Antenna For Microwave Treatment

    NASA Technical Reports Server (NTRS)

    Arndt, G. Dickey (Inventor); Carl, James R. (Inventor); Raffoul, George W. (Inventor); Karasack, Vincent G. (Inventor); Pacifico, Antonio (Inventor); Pieper, Carl F. (Inventor)

    2000-01-01

    Method and apparatus are provided for propagating microwave energy into heart tissues to produce a desired temperature profile therein at tissue depths sufficient for thermally ablating arrhythmogenic cardiac tissue to treat ventricular tachycardia and other arrhythmias while preventing excessive heating of surrounding tissues, organs, and blood. A wide bandwidth double-disk antenna is effective for this purpose over a bandwidth of about six gigahertz. A computer simulation provides initial screening capabilities for an antenna such as antenna, frequency, power level, and power application duration. The simulation also allows optimization of techniques for specific patients or conditions. In operation, microwave energy between about 1 Gigahertz and 12 Gigahertz is applied to monopole microwave radiation having a surface wave limiter. A test setup provides physical testing of microwave radiators to determine the temperature profile created in actual heart tissue or ersatz heart tissue. Saline solution pumped over the heart tissue with a peristaltic pump simulates blood flow. Optical temperature sensors disposed at various tissue depths within the heart tissue detect the temperature profile without creating any electromagnetic interference. The method may he used to produce a desired temperature profile in other body tissues reachable by catheter such as tumors and the like.

  16. The Barriers and Facilitators to Transfer of Ultrasound-Guided Central Venous Line Skills From Simulation to Practice: Exploring Perceptions of Learners and Supervisors.

    PubMed

    Mema, Briseida; Harris, Ilene

    2016-01-01

    PHENOMENON: Ultrasound-guided central venous line insertion is currently the standard of care. Randomized controlled trials and systematic reviews show that simulation is superior to apprenticeship training. The purpose of this study is to explore, from the perspectives of participants in a simulation-training program, the factors that help or hinder the transfer of skills from simulation to practice. Purposeful sampling was used to select and study the experience and perspective of novice fellows after they had completed simulation training and then performed ultrasound-guided central venous line in practice. Seven novice pediatric intensive care unit fellows and six supervising faculty in a university-affiliated academic center in a large urban city were recruited between September 2012 and January 2013. We conducted a qualitative study using semistructured interviews as our data source, employing a constructivist, grounded theory methodology. Both curricular and real-life factors influence the transfer of skills from simulation to practice and the overall performance of trainees. Clear instructions, the opportunity to practice to mastery, one-on-one observation with feedback, supervision, and further real-life experiences were perceived as factors that facilitated the transfer of skills. Concern for patient welfare, live trouble shooting, complexity of the intensive care unit environment, and the procedure itself were perceived as real-life factors that hindered the transfer of skills. Insights: As more studies confirm the superiority of simulation training versus apprenticeship training for initial student learning, the faculty should gain insight into factors that facilitate and hinder the transfer of skills from simulation to bedside settings and impact learners' performances. As simulation further augments clinical learning, efforts should be made to modify the curricular and bedside factors that facilitate transfer of skills from simulation to practice settings.

  17. Accelerating cardiac bidomain simulations using graphics processing units.

    PubMed

    Neic, A; Liebmann, M; Hoetzl, E; Mitchell, L; Vigmond, E J; Haase, G; Plank, G

    2012-08-01

    Anatomically realistic and biophysically detailed multiscale computer models of the heart are playing an increasingly important role in advancing our understanding of integrated cardiac function in health and disease. Such detailed simulations, however, are computationally vastly demanding, which is a limiting factor for a wider adoption of in-silico modeling. While current trends in high-performance computing (HPC) hardware promise to alleviate this problem, exploiting the potential of such architectures remains challenging since strongly scalable algorithms are necessitated to reduce execution times. Alternatively, acceleration technologies such as graphics processing units (GPUs) are being considered. While the potential of GPUs has been demonstrated in various applications, benefits in the context of bidomain simulations where large sparse linear systems have to be solved in parallel with advanced numerical techniques are less clear. In this study, the feasibility of multi-GPU bidomain simulations is demonstrated by running strong scalability benchmarks using a state-of-the-art model of rabbit ventricles. The model is spatially discretized using the finite element methods (FEM) on fully unstructured grids. The GPU code is directly derived from a large pre-existing code, the Cardiac Arrhythmia Research Package (CARP), with very minor perturbation of the code base. Overall, bidomain simulations were sped up by a factor of 11.8 to 16.3 in benchmarks running on 6-20 GPUs compared to the same number of CPU cores. To match the fastest GPU simulation which engaged 20 GPUs, 476 CPU cores were required on a national supercomputing facility.

  18. Accelerating Cardiac Bidomain Simulations Using Graphics Processing Units

    PubMed Central

    Neic, Aurel; Liebmann, Manfred; Hoetzl, Elena; Mitchell, Lawrence; Vigmond, Edward J.; Haase, Gundolf

    2013-01-01

    Anatomically realistic and biophysically detailed multiscale computer models of the heart are playing an increasingly important role in advancing our understanding of integrated cardiac function in health and disease. Such detailed simulations, however, are computationally vastly demanding, which is a limiting factor for a wider adoption of in-silico modeling. While current trends in high-performance computing (HPC) hardware promise to alleviate this problem, exploiting the potential of such architectures remains challenging since strongly scalable algorithms are necessitated to reduce execution times. Alternatively, acceleration technologies such as graphics processing units (GPUs) are being considered. While the potential of GPUs has been demonstrated in various applications, benefits in the context of bidomain simulations where large sparse linear systems have to be solved in parallel with advanced numerical techniques are less clear. In this study, the feasibility of multi-GPU bidomain simulations is demonstrated by running strong scalability benchmarks using a state-of-the-art model of rabbit ventricles. The model is spatially discretized using the finite element methods (FEM) on fully unstructured grids. The GPU code is directly derived from a large pre-existing code, the Cardiac Arrhythmia Research Package (CARP), with very minor perturbation of the code base. Overall, bidomain simulations were sped up by a factor of 11.8 to 16.3 in benchmarks running on 6–20 GPUs compared to the same number of CPU cores. To match the fastest GPU simulation which engaged 20GPUs, 476 CPU cores were required on a national supercomputing facility. PMID:22692867

  19. Arrhythmia as a cardiac manifestation in MELAS syndrome.

    PubMed

    Thomas, Tamara; Craigen, William J; Moore, Ryan; Czosek, Richard; Jefferies, John L

    2015-09-01

    A 44-year-old female with a diagnosis of mitochondrial myopathy, encephalopathy and stroke-like episodes (MELAS) syndrome had progressive left ventricular hypertrophy (LVH) on echocardiogram. A Holter monitor demonstrated episodes of non-sustained atrial tachycardia, a finding not been previously described in this population. This unique case of MELAS syndrome demonstrates the known associated cardiac manifestation of LVH and the new finding of atrial tachycardia which may represent the potential for subclinical arrhythmia in this population.

  20. Development of the cardiac pacemaker

    PubMed Central

    Liang, Xingqun; Evans, Sylvia M.

    2017-01-01

    The sinoatrial node (SAN) is the dominant pacemaker of the heart. Abnormalities in SAN formation and function can cause sinus arrhythmia, including sick sinus syndrome and sudden death. A better understanding of genes and signaling pathways that regulate SAN development and function is essential to develop more effective treatment to sinus arrhythmia, including biological pacemakers. In this review, we briefly summarize the key processes of SAN morphogenesis during development, and focus on the transcriptional network that drives SAN development. PMID:27770149

  1. Diagnostic accuracy of a smartphone electrocardiograph in dogs: Comparison with standard 6-lead electrocardiography.

    PubMed

    Vezzosi, T; Buralli, C; Marchesotti, F; Porporato, F; Tognetti, R; Zini, E; Domenech, O

    2016-10-01

    The diagnostic accuracy of a smartphone electrocardiograph (ECG) in evaluating heart rhythm and ECG measurements was evaluated in 166 dogs. A standard 6-lead ECG was acquired for 1 min in each dog. A smartphone ECG tracing was simultaneously recorded using a single-lead bipolar ECG recorder. All ECGs were reviewed by one blinded operator, who judged if tracings were acceptable for interpretation and assigned an electrocardiographic diagnosis. Agreement between smartphone and standard ECG in the interpretation of tracings was evaluated. Sensitivity and specificity for the detection of arrhythmia were calculated for the smartphone ECG. Smartphone ECG tracings were interpretable in 162/166 (97.6%) tracings. A perfect agreement between the smartphone and standard ECG was found in detecting bradycardia, tachycardia, ectopic beats and atrioventricular blocks. A very good agreement was found in detecting sinus rhythm versus non-sinus rhythm (100% sensitivity and 97.9% specificity). The smartphone ECG provided tracings that were adequate for analysis in most dogs, with an accurate assessment of heart rate, rhythm and common arrhythmias. The smartphone ECG represents an additional tool in the diagnosis of arrhythmias in dogs, but is not a substitute for a 6-lead ECG. Arrhythmias identified by the smartphone ECG should be followed up with a standard ECG before making clinical decisions. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Ambient temperature and activation of implantable cardioverter defibrillators

    NASA Astrophysics Data System (ADS)

    McGuinn, L.; Hajat, S.; Wilkinson, P.; Armstrong, B.; Anderson, H. R.; Monk, V.; Harrison, R.

    2013-09-01

    The degree to which weather influences the occurrence of serious cardiac arrhythmias is not fully understood. To investigate, we studied the timing of activation of implanted cardiac defibrillators (ICDs) in relation to daily outdoor temperatures using a fixed stratum case-crossover approach. All patients attending ICD clinics in London between 1995 and 2003 were recruited onto the study. Temperature exposure for each ICD patient was determined by linking each patient's postcode of residence to their nearest temperature monitoring station in London and the South of England. There were 5,038 activations during the study period. Graphical inspection of ICD activation against temperature suggested increased risk at lower but not higher temperatures. For every 1 °C decrease in ambient temperature, risk of ventricular arrhythmias up to 7 days later increased by 1.2 % (95 % CI -0.6 %, 2.9 %). In threshold models, risk of ventricular arrhythmias increased by 11.2 % (0.5 %, 23.1 %) for every 1° decrease in temperature below 2 °C. Patients over the age of 65 exhibited the highest risk. This large study suggests an inverse relationship between ambient outdoor temperature and risk of ventricular arrhythmias. The highest risk was found for patients over the age of 65. This provides evidence about a mechanism for some cases of low-temperature cardiac death, and suggests a possible strategy for reducing risk among selected cardiac patients by encouraging behaviour modification to minimise cold exposure.

  3. Bayesian Classification Models for Premature Ventricular Contraction Detection on ECG Traces.

    PubMed

    Casas, Manuel M; Avitia, Roberto L; Gonzalez-Navarro, Felix F; Cardenas-Haro, Jose A; Reyna, Marco A

    2018-01-01

    According to the American Heart Association, in its latest commission about Ventricular Arrhythmias and Sudden Death 2006, the epidemiology of the ventricular arrhythmias ranges from a series of risk descriptors and clinical markers that go from ventricular premature complexes and nonsustained ventricular tachycardia to sudden cardiac death due to ventricular tachycardia in patients with or without clinical history. The premature ventricular complexes (PVCs) are known to be associated with malignant ventricular arrhythmias and sudden cardiac death (SCD) cases. Detecting this kind of arrhythmia has been crucial in clinical applications. The electrocardiogram (ECG) is a clinical test used to measure the heart electrical activity for inferences and diagnosis. Analyzing large ECG traces from several thousands of beats has brought the necessity to develop mathematical models that can automatically make assumptions about the heart condition. In this work, 80 different features from 108,653 ECG classified beats of the gold-standard MIT-BIH database were extracted in order to classify the Normal, PVC, and other kind of ECG beats. Three well-known Bayesian classification algorithms were trained and tested using these extracted features. Experimental results show that the F1 scores for each class were above 0.95, giving almost the perfect value for the PVC class. This gave us a promising path in the development of automated mechanisms for the detection of PVC complexes.

  4. Cardiac mast cell-derived renin promotes local angiotensin formation, norepinephrine release, and arrhythmias in ischemia/reperfusion.

    PubMed

    Mackins, Christina J; Kano, Seiichiro; Seyedi, Nahid; Schäfer, Ulrich; Reid, Alicia C; Machida, Takuji; Silver, Randi B; Levi, Roberto

    2006-04-01

    Having identified renin in cardiac mast cells, we assessed whether its release leads to cardiac dysfunction. In Langendorff-perfused guinea pig hearts, mast cell degranulation with compound 48/80 released Ang I-forming activity. This activity was blocked by the selective renin inhibitor BILA2157, indicating that renin was responsible for Ang I formation. Local generation of cardiac Ang II from mast cell-derived renin also elicited norepinephrine release from isolated sympathetic nerve terminals. This action was mediated by Ang II-type 1 (AT1) receptors. In 2 models of ischemia/reperfusion using Langendorff-perfused guinea pig and mouse hearts, a significant coronary spillover of renin and norepinephrine was observed. In both models, this was accompanied by ventricular fibrillation. Mast cell stabilization with cromolyn or lodoxamide markedly reduced active renin overflow and attenuated both norepinephrine release and arrhythmias. Similar cardioprotection was observed in guinea pig hearts treated with BILA2157 or the AT1 receptor antagonist EXP3174. Renin overflow and arrhythmias in ischemia/reperfusion were much less prominent in hearts of mast cell-deficient mice than in control hearts. Thus, mast cell-derived renin is pivotal for activating a cardiac renin-angiotensin system leading to excessive norepinephrine release in ischemia/reperfusion. Mast cell-derived renin may be a useful therapeutic target for hyperadrenergic dysfunctions, such as arrhythmias, sudden cardiac death, myocardial ischemia, and congestive heart failure.

  5. Determination of myocardium to plasma concentration ratios of five antipsychotic drugs: comparison with their ability to induce arrhythmia and sudden death in clinical practice.

    PubMed

    Titier, Karine; Canal, Mireille; Déridet, Evelyne; Abouelfath, Abdelilah; Gromb, Sophie; Molimard, Mathieu; Moore, Nicholas

    2004-08-15

    Reviewing available data shows that most of antipsychotic drugs are associated with arrhythmia and sudden death. Experimental studies have shown a HERG channel blockade, a dose-dependent increase in duration of action potential or of QT interval, with various degrees of indicators of serious arrhythmogenicity. However, it seems difficult to relate these in vitro and in vivo preclinical models to clinical findings, in part, because the relationship between concentrations used and in vivo tissue concentrations during treatment in man is not known. Consequently, we established the myocardium to plasma concentration ratios for a series of antipsychotic drugs by intraperitoneal administration of different level doses to the guinea pig. Then, we compared these values to their ability to induce arrhythmia or torsade de pointes in clinical practice. The myocardium to plasma concentration ratios were 2.2 for clozapine, 2.7 for olanzapine, 3.1 for sertindole, 4.5 for risperidone, and 6.4 for haloperidol. These data suggest that when the ratio is higher than 4, arrhythmia and sudden death may be expected. On the contrary, when the ratio is less than 3, little effect may be predicted. These results underscore the importance of interpreting HERG channel data and electrophysiological data in the context of other pharmacokinetic parameters such as myocardium to plasma distribution.

  6. Exploring the Lived Experiences of Participants in Simulation-Based Learning Activities

    ERIC Educational Resources Information Center

    Beard, Rachael

    2013-01-01

    There is currently a small body of research on the experiences of participants, both facilitators and learners, during simulated mock codes (cardiac arrest) in the healthcare setting. This study was based on a practitioner's concerns that mock codes are facilitated differently among educators, mock codes are not aligned with andragogy theory of…

  7. The relationship between facilitators' questions and the level of reflection in postsimulation debriefing.

    PubMed

    Husebø, Sissel Eikeland; Dieckmann, Peter; Rystedt, Hans; Søreide, Eldar; Friberg, Febe

    2013-06-01

    Simulation-based education is a learner-active method that may enhance teamwork skills such as leadership and communication. The importance of postsimulation debriefing to promote reflection is well accepted, but many questions concerning whether and how faculty promote reflection remain largely unanswered in the research literature. The aim of this study was therefore to explore the depth of reflection expressed in questions by facilitators and responses from nursing students during postsimulation debriefings. Eighty-one nursing students and 4 facilitators participated. The data were collected in February and March 2008, the analysis being conducted on 24 video-recorded debriefings from simulated resuscitation teamwork involving nursing students only. Using Gibbs' reflective cycle, we graded the facilitators' questions and nursing students' responses into stages of reflection and then correlated these. Facilitators asked most evaluative and fewest emotional questions, whereas nursing students answered most evaluative and analytic responses and fewest emotional responses. The greatest difference between facilitators and nursing students was in the analytic stage. Only 23 (20%) of 117 questions asked by the facilitators were analytic, whereas 45 (35%) of 130 students' responses were rated as analytic. Nevertheless, the facilitators' descriptive questions also elicited student responses in other stages such as evaluative and analytic responses. We found that postsimulation debriefings provide students with the opportunity to reflect on their simulation experience. Still, if the debriefing is going to pave the way for student reflection, it is necessary to work further on structuring the debriefing to facilitate deeper reflection. Furthermore, it is important that facilitators consider what kind of questions they ask to promote reflection. We think future research on debriefing should focus on developing an analytical framework for grading reflective questions. Such research will inform and support facilitators in devising strategies for the promotion of learning through reflection in postsimulation debriefings.

  8. Myocardial deletion of transcription factor CHF1/Hey2 results in altered myocyte action potential and mild conduction system expansion but does not alter conduction system function or promote spontaneous arrhythmias.

    PubMed

    Hartman, Matthew E; Liu, Yonggang; Zhu, Wei-Zhong; Chien, Wei-Ming; Weldy, Chad S; Fishman, Glenn I; Laflamme, Michael A; Chin, Michael T

    2014-07-01

    CHF1/Hey2 is a Notch-responsive basic helix-loop-helix transcription factor involved in cardiac development. Common variants in Hey2 are associated with Brugada syndrome. We hypothesized that absence of CHF1/Hey2 would result in abnormal cellular electrical activity, altered cardiac conduction system (CCS) development, and increased arrhythmogenesis. We isolated neonatal CHF/Hey2-knockout (KO) cardiac myocytes and measured action potentials and ion channel subunit gene expression. We also crossed myocardial-specific CHF1/Hey2-KO mice with cardiac conduction system LacZ reporter mice and stained for conduction system tissue. We also performed ambulatory ECG monitoring for arrhythmias and heart rate variability. Neonatal cardiomyocytes from CHF1/Hey2-KO mice demonstrate a 50% reduction in action potential dV/dT, a 50-75% reduction in SCN5A, KCNJ2, and CACNA1C ion channel subunit gene expression, and an increase in delayed afterdepolarizations from 0/min to 12/min. CHF1/Hey2 cKO CCS-lacZ mice have a ∼3-fold increase in amount of CCS tissue. Ambulatory ECG monitoring showed no difference in cardiac conduction, arrhythmias, or heart rate variability. Wild-type cells or animals were used in all experiments. CHF1/Hey2 may contribute to Brugada syndrome by influencing the expression of SCN5A and formation of the cardiac conduction system, but its absence does not cause baseline conduction defects or arrhythmias in the adult mouse.-Hartman, M. E., Liu, Y., Zhu, W.-Z., Chien, W.-M., Weldy, C. S., Fishman, G. I., Laflamme, M. A., Chin, M. T. Myocardial deletion of transcription factor CHF1/Hey2 results in altered myocyte action potential and mild conduction system expansion but does not alter conduction system function or promote spontaneous arrhythmias. © FASEB.

  9. Evaluation of echocardiography and cardiac biomarker concentrations in dogs with gastric dilatation volvulus.

    PubMed

    Aona, Brent D; Rush, John E; Rozanski, Elizabeth A; Cunningham, Suzanne M; Sharp, Claire R; Freeman, Lisa M

    2017-11-01

    To assess abnormalities in concentrations of cardiac troponin I (cTnI), lactate, and N-terminal pro-B-type natriuretic peptide (NT-proBNP) in relation to arrhythmias, echocardiographic measurements, and survival in dogs with gastric dilatation volvulus (GDV). Prospective observational study. University hospital. Twenty-two dogs with naturally occurring GDV. Concentrations of cTnI, plasma lactate, and NT-proBNP were recorded at presentation to the emergency room, the time closest to echocardiography, and the highest recorded concentrations during hospitalization. None. Cardiac rhythms were categorized on a 0-4 scale (0 = no ventricular premature complexes [VPCs], 1 = single VPCs, 2 = bigeminy or trigeminy, 3 = couplets or triplets, and 4 = R-on-T phenomenon or ventricular tachycardia). Echocardiography was performed 6-18 hours postoperatively. Fifteen dogs had ventricular arrhythmias during hospitalization (Grade 1 [n = 9], Grade 4 [n = 6]). The highest recorded cTnI concentration was significantly higher in the dogs with Grade 4 (P = 0.002) or Grade 1 (P = 0.001) arrhythmias compared to dogs without arrhythmias. Plasma lactate was significantly correlated with left ventricular internal diameter in diastole (r = -0.52, P = 0.01) and systole (r = -0.57, P = 0.006), left ventricular free wall in diastole (LWDd, r = 0.59, P = 0.004), and interventricular septal thickness in diastole (IVDs, r = 0.65, P = 0.001). Dogs that did not survive to 1 week postdischarge (3/22) had a significantly thicker LVWd (P = 0.04) and IVSd (P = 0.05), and received significantly less fluids in the first 24 (P = 0.02) and 48 hours (P = 0.03) of hospitalization. Concentrations of cTnI and NT-proBNP increased during hospitalization, but only cTnI concentrations were significantly higher in dogs with a higher arrhythmia grade. Additional research on the potential role of serial measurement of biomarkers in dogs with GDV is warranted. © Veterinary Emergency and Critical Care Society 2017.

  10. Cardiac Arrhythmia: In vivo screening in the zebrafish to overcome complexity in drug discovery.

    PubMed

    Macrae, Calum A

    2010-07-01

    IMPORTANCE OF THE FIELD: Cardiac arrhythmias remain a major challenge for modern drug discovery. Clinical events are paroxysmal, often rare and may be asymptomatic until a highly morbid complication. Target selection is often based on limited information and though highly specific agents are identified in screening, the final efficacy is often compromised by unanticipated systemic responses, a narrow therapeutic index and substantial toxicities. AREAS COVERED IN THIS REVIEW: Our understanding of complexity of arrhythmogenesis has grown dramatically over the last two decades, and the range of potential disease mechanisms now includes pathways previously thought only tangentially involved in arrhythmia. This review surveys the literature on arrhythmia mechanisms from 1965 to the present day, outlines the complex biology underlying potentially each and every rhythm disturbance, and highlights the problems for rational target identification. The rationale for in vivo screening is described and the utility of the zebrafish for this approach and for complementary work in functional genomics is discussed. Current limitations of the model in this setting and the need for careful validation in new disease areas are also described. WHAT THE READER WILL GAIN: An overview of the complex mechanisms underlying most clinical arrhythmias, and insight into the limits of ion channel conductances as drug targets. An introduction to the zebrafish as a model organism, in particular for cardiovascular biology. Potential approaches to overcoming the hurdles to drug discovery in the face of complex biology including in vivo screening of zebrafish genetic disease models. TAKE HOME MESSAGE: In vivo screening in faithful disease models allows the effects of drugs on integrative physiology and disease biology to be captured during the screening process, in a manner agnostic to potential drug target or targets. This systematic strategy bypasses current gaps in our understanding of disease biology, but emphasizes the importance of the rigor of the disease model.

  11. Venturing into ventricular arrhythmia storm: a systematic review and meta-analysis.

    PubMed

    Nayyar, Sachin; Ganesan, Anand N; Brooks, Anthony G; Sullivan, Thomas; Roberts-Thomson, Kurt C; Sanders, Prashanthan

    2013-02-01

    Ablation has substantial evidence base in the management of ventricular arrhythmia (VA). It can be a 'lifesaving' procedure in the acute setting of VA storm. Current reports on ablation in VA storm are in the form of small series and have relative small representation in a large observational series. The purpose of this study was to systematically synthesize the available literature to appreciate the efficacy and safety of ablation in the setting of VA storm. The medical electronic databases through 31 January 2012 were searched. Ventricular arrhythmia storm was defined as recurrent (≥ 3 episodes or defibrillator therapies in 24 h) or incessant (continuous >12 h) VA. Studies reporting data on VA storm patients at the individual or study level were included. A total of 471 VA storm patients from 39 publications were collated for the analysis. All VAs were successfully ablated in 72% [95% confidence interval (CI) 71-89%] and 9% (95% CI: 3-10%) had a failed procedure. Procedure-related mortality occurred in three patients (0.6%). Only 6% patients had a recurrence of VA storm. The recurrence of VA was significantly higher after ablation for arrhythmic storm of monomorphic ventricular tachycardia (VT) relative to ventricular fibrillation or polymorphic VT with underlying cardiomyopathy (odds ratio 3.76; 95% CI: 1.65-8.57; P = 0.002). During the follow-up (61 ± 37 weeks), 17% of patients died (heart failure 62%, arrhythmias 23%, and non-cardiac 15%) with 55% deaths occurring within 12 weeks of intervention. The odds of death were four times higher after a failed procedure compared with those with a successful procedure (95% CI: 2.04-8.01, P < 0.001). Ventricular arrhythmia storm ablation has high-acute success rates, with a low rate of recurrent storms. Heart failure is the dominant cause of death in the long term. Failure of the acute procedure carries a high mortality.

  12. Interleukin 1 alpha-induced expression of manganous superoxide dismutase reduces myocardial reperfusion injury in the rat.

    PubMed

    Nogae, C; Makino, N; Hata, T; Nogae, I; Takahashi, S; Suzuki, K; Taniguchi, N; Yanaga, T

    1995-10-01

    We investigated the effects of pretreatment with interleukin (IL)-1 alpha on the expression of manganous (Mn) superoxide dismutase (SOD) mRNA and reperfusion-induced arrhythmias and the size of myocardial infarct in rats. Male Wistar rats received 10 mg intraperitoneal injections of human recombinant IL-1 alpha. Their hearts were thereafter isolated at 6, 12, 24, 36 h. A Northern analysis showed that Mn-SOD mRNA was mainly expressed in the heart and slightly in kidney, but not in any other organs. The expression of Mn-SOD mRNA peaked at 6 h after the injection of IL-1 alpha. The Mn-SOD protein content was most increased 12 h after injection. In the isolated heart model, the rats were pretreated with IL-1 alpha 24 h earlier and their hearts were perfused by the Langendorff method. After 20 min of ischemia which was induced by a ligation of a coronary artery, reperfusion-induced arrhythmias were observed. There were no significant differences in the incidence of ventricular arrhythmias between the IL-1 alpha pretreated and the untreated hearts. IL-1 alpha pretreatment significantly reduced the mean duration of the ventricular arrhythmias and also delayed the onset of arrhythmias. The effect of IL-1 alpha pretreatment was also investigated in a 30-min model of ischemia followed by a 3-min reperfusion in anesthetized rats. The infarct size expressed as a percentage of the area at risk was significantly reduced in the IL-1 alpha pretreated hearts compared with the untreated hearts. The left ventricular systolic pressure increased significantly in rat hearts pretreated with IL-1 alpha. Our results therefore showed that the pretreatment with IL-1 alpha induced the overexpression of Mn-SOD mRNA in the rat hearts and also suggested that pretreatment with IL-1 alpha 24 h before ischemia reduced the risk of ischemia-reperfusion injury.

  13. Discrete potentials guided radiofrequency ablation for idiopathic outflow tract ventricular arrhythmias.

    PubMed

    Liu, Enzhao; Xu, Gang; Liu, Tong; Ye, Lan; Zhang, Qitong; Zhao, Yanshu; Li, Guangping

    2015-03-01

    Discrete potentials (DPs) have been recorded and targeted as the site of ablation of the outflow tract arrhythmias. The aim of the present study was to investigate the significance of DPs with respect to mapping and ablation for idiopathic outflow tract premature ventricular contractions (PVCs) or ventricular tachycardias (VTs). Seventeen consecutive patients with idiopathic right or left ventricular outflow tract PVCs/VTs who underwent radiofrequency catheter ablation were included. Intracardiac electrograms during the mapping and ablation were analysed. During sinus rhythm, sharp high-frequency DPs that displayed double or multiple components were recorded following or buried in the local ventricular electrograms in all of the 17 patients, peak amplitude 0.51 ± 0.21 mV. The same potential was recorded prior to the local ventricular potential of the PVCs/VTs. Spontaneous reversal of the relationship of the DPs to the local ventricular electrogram during the arrhythmias was noted. The DPs were related to a region of low voltage showed by intracardiac high-density contact mapping. At the sites with DPs, lower unipolar and bipolar ventricular voltage of sinus beats were noted compared with the adjacent regions without DPs (unipolar: 6.1 ± 1.8 vs. 8.3 ± 2.3 mV, P < 0.05; bipolar: 0.62 ± 0.45 vs. 1.03 ± 0.60 mV, P < 0.05). The targeted DPs were still present in 12 patients after successful elimination of the ectopies. Discrete potentials were not present in seven controls. Discrete potentials and related low-voltage regions were common in idiopathic outflow tract ventricular arrhythmias. Discrete potential- and substrate-guided ablation strategy will help to reduce the recurrence of idiopathic outflow tract arrhythmias. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.

  14. Prevention of fatal arrhythmias in high-risk subjects by fish oil n-3 fatty acid intake.

    PubMed

    Leaf, Alexander; Albert, Christine M; Josephson, Mark; Steinhaus, David; Kluger, Jeffrey; Kang, Jing X; Cox, Benjamin; Zhang, Hui; Schoenfeld, David

    2005-11-01

    The long-chain n-3 fatty acids in fish have been demonstrated to have antiarrhythmic properties in experimental models and to prevent sudden cardiac death in a randomized trial of post-myocardial infarction patients. Therefore, we hypothesized that these n-3 fatty acids might prevent potentially fatal ventricular arrhythmias in high-risk patients. Four hundred two patients with implanted cardioverter/defibrillators (ICDs) were randomly assigned to double-blind treatment with either a fish oil or an olive oil daily supplement for 12 months. The primary end point, time to first ICD event for ventricular tachycardia or fibrillation (VT or VF) confirmed by stored electrograms or death from any cause, was analyzed by intention to treat. Secondary analyses were performed for "probable" ventricular arrhythmias, "on-treatment" analyses for all subjects who had taken any of their oil supplements, and "on-treatment" analyses only of those subjects who were on treatment for at least 11 months. Compliance with double-blind treatment was similar in the 2 groups; however, the noncompliance rate was high (35% of all enrollees). In the primary analysis, assignment to treatment with the fish oil supplement showed a trend toward a prolonged time to the first ICD event (VT or VF) or of death from any cause (risk reduction of 28%; P=0.057). When therapies for probable episodes of VT or VF were included, the risk reduction became significant at 31%; P=0.033. For those who stayed on protocol for at least 11 months, the antiarrhythmic benefit of fish oil was improved for those with confirmed events (risk reduction of 38%; P=0.034). Although significance was not achieved for the primary end point, this study provides evidence that for individuals at high risk of fatal ventricular arrhythmias, regular daily ingestion of fish oil fatty acids may significantly reduce potentially fatal ventricular arrhythmias.

  15. Inhibitions of late INa and CaMKII act synergistically to prevent ATX-II-induced atrial fibrillation in isolated rat right atria.

    PubMed

    Liang, Faquan; Fan, Peidong; Jia, Jessie; Yang, Suya; Jiang, Zhan; Karpinski, Serge; Kornyeyev, Dmytro; Pagratis, Nikos; Belardinelli, Luiz; Yao, Lina

    2016-05-01

    Increases in late Na(+) current (late INa) and activation of Ca(2+)/calmodulin-dependent protein kinase (CaMKII) are associated with atrial arrhythmias. CaMKII also phosphorylates Nav1.5, further increasing late INa. The combination of a CaMKII inhibitor with a late INa inhibitor may be superior to each compound alone to suppress atrial arrhythmias. Therefore, we investigated the effect of a CaMKII inhibitor in combination with a late INa inhibitor on anemone toxin II (ATX-II, a late INa enhancer)-induced atrial arrhythmias. Rat right atrial tissue was isolated and preincubated with either the CaMKII inhibitor autocamtide-2-related inhibitory peptide (AIP), the late INa inhibitor GS458967, or both, and then exposed to ATX-II. ATX-II increased diastolic tension and caused fibrillation of isolated right atrial tissue. AIP (0.3μmol/L) and 0.1μmol/L GS458967 alone inhibited ATX-II-induced arrhythmias by 20±3% (mean±SEM, n=14) and 34±5% (n=13), respectively, whereas the two compounds in combination inhibited arrhythmias by 81±4% (n=10, p<0.05, vs either AIP or GS458967 alone or the calculated sum of individual effects of both compounds). AIP and GS458967 also attenuated the ATX-induced increase of diastolic tension. Consistent with the mechanical and electrical data, 0.3μmol/L AIP and 0.1μmol/L GS458967 each inhibited ATX-II-induced CaMKII phosphorylation by 23±3% and 32±4%, whereas the combination of both compounds inhibited CaMKII phosphorylation completely. The effects of an enhanced late INa to induce arrhythmic activity and activation of CaMKII in atria are attenuated synergistically by inhibitors of late INa and CaMKII. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Particulate Air Pollution, Ambulatory Heart Rate Variability, and Cardiac Arrhythmia in Retirement Community Residents with Coronary Artery Disease

    PubMed Central

    Longhurst, John; Tjoa, Thomas; Sioutas, Constantinos; Delfino, Ralph J.

    2013-01-01

    Background: Decreased heart rate variability (HRV) has been associated with future cardiac morbidity and mortality and is often used as a marker of altered cardiac autonomic balance in studies of health effects of airborne particulate matter. Fewer studies have evaluated associations between air pollutants and cardiac arrhythmia. Objectives: We examined relationships between cardiac arrhythmias, HRV, and exposures to airborne particulate matter. Methods: We measured HRV and arrhythmia with ambulatory electrocardiograms in a cohort panel study for up to 235 hr per participant among 50 nonsmokers with coronary artery disease who were ≥ 71 years of age and living in four retirement communities in the Los Angeles, California, Air Basin. Exposures included hourly outdoor gases, hourly traffic-related and secondary organic aerosol markers, and daily size-fractionated particle mass. We used repeated measures analyses, adjusting for actigraph-derived physical activity and heart rate, temperature, day of week, season, and community location. Results: Ventricular tachycardia was significantly increased in association with increases in markers of traffic-related particles, secondary organic carbon, and ozone. Few consistent associations were observed for supraventricular tachycardia. Particulates were significantly associated with decreased ambulatory HRV only in the 20 participants using ACE (angiotensin I–converting enzyme) inhibitors. Conclusions: Although these data support the hypothesis that particulate exposures may increase the risk of ventricular tachycardia for elderly people with coronary artery disease, HRV was not associated with exposure in most of our participants. These results are consistent with previous findings in this cohort for systemic inflammation, blood pressure, and ST segment depression. Citation: Bartell SM, Longhurst J, Tjoa T, Sioutas C, Delfino RJ. 2013. Particulate air pollution, ambulatory heart rate variability, and cardiac arrhythmia in retirement community residents with coronary artery disease. Environ Health Perspect 121:1135–1141; http://dx.doi.org/10.1289/ehp.1205914 PMID:23838152

  17. Hyperventilation assists proarrhythmia development during delayed repolarization in clofilium-treated, anaesthetized, mechanically ventilated rabbits.

    PubMed

    Papp, H; Sarusi, A; Farkas, A S; Takacs, H; Kui, P; Vincze, D; Ivany, E; Varro, A; Papp, J G; Forster, T; Farkas, A

    2016-10-01

    Hyperventilation reduces partial pressure of CO 2 (PCO 2 ) in the blood, which results in hypokalaemia. Hypokalaemia helps the development of the life-threatening torsades de pointes type ventricular arrhythmia (TdP) evoked by repolarization delaying drugs. This implies that hyperventilation may assist the development of proarrhythmic events. Therefore, this study experimentally investigated the effect of hyperventilation on proarrhythmia development during delayed repolarization. Phenylephrine (an α 1 -adrenoceptor agonist) and clofilium (as a representative repolarization delaying agent inhibiting the rapid component of the delayed rectifier potassium current, I Kr ) were administered intravenously to pentobarbital-anaesthetized, mechanically ventilated, open chest rabbits. ECG was recorded, and the onset times and incidences of the arrhythmias were determined. Serum K + , pH and PCO 2 were measured in arterial blood samples. Clofilium prolonged the rate corrected QT interval. TdP occurred in 15 animals (TdP+ group), and did not occur in 14 animals (TdP- group). We found a strong, positive, linear correlation between serum K + and PCO 2 . There was no relationship between the occurrence of TdP and the baseline K + and PCO 2 values. However, a positive, linear correlation was found between the onset time of the first arrhythmias and the K + and PCO 2 values. The regression lines describing the relationship between PCO 2 and onset time of first arrhythmias were parallel in the TdP+ and TdP- groups, but the same PCO 2 resulted in earlier arrhythmia onset in the TdP+ group than in the TdP- group. We conclude that hyperventilation and hypocapnia with the resultant hypokalaemia assist the multifactorial process of proarrhythmia development during delayed repolarization. This implies that PCO 2 and serum K + should be controlled tightly during mechanical ventilation in experimental investigations and clinical settings when repolarization-delaying drugs are applied.

  18. Atrial arrhythmias after lung transplant: underlying mechanisms, risk factors, and prognosis.

    PubMed

    Orrego, Carlos M; Cordero-Reyes, Andrea M; Estep, Jerry D; Seethamraju, Harish; Scheinin, Scott; Loebe, Matthias; Torre-Amione, Guillermo

    2014-07-01

    Atrial arrhythmias (AAs) early after lung transplant are frequent and have a significant impact on morbidity and mortality. However, the pathogenesis of AAs after lung transplant remains incompletely understood. In this study we aimed to determine the prevalence of atrial fibrillation (AF) and other AAs, as well as risk factors, clinical outcomes and possible underlying mechanisms associated with AAs after lung transplant. A retrospective analysis was performed on 382 patients who underwent lung transplantation from 2000 to 2010. A 12-lead electrocardiogram (ECG) was obtained and AAs classified as AF and other AAs (atrial flutter [AFL] and supraventricular tachycardia [SVT]). Multivariate logistic regression analysis was performed to determine predictors, and Kaplan-Meier survival curves were constructed. The incidence of AAs was 25%; 17.8% developed AF and 7.6% other AAs (AFL/SVT). The major indication for transplant was idiopathic pulmonary fibrosis (IPF, 35%). Significant predictors of AF were as follows: age; IPF; left atrial enlargement; diastolic dysfunction; and history of coronary artery disease (CAD). Risk factors for other AAs (AFL/SVT) were: age; right ventricle dysfunction; right ventricular enlargement; and elevated right atrial pressure (RAP). One-year mortality was higher in the arrhythmia group (21.5% arrhythmia vs 15.7% no-arrhythmia group; p < 0.05). In addition, patients treated with anti-arrhythmic medications had higher mortality (p < 0.05). AAs are common after lung transplantation. Risk factors for developing either AF or other AAs (AFL/SVT) are different. The development of early AAs post-transplant is associated with prolonged post-operative stay and increased mortality. A rate-control strategy should be used as first-line therapy and anti-arrhythmic agents reserved for those patients who do not respond to the initial treatment. Copyright © 2014 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  19. [Clinical evaluation of the anti-arrhythmic properties and cardiohemodynamic effects of the basic anti-arrhythmia agents].

    PubMed

    Stoliarchuk, A A; Storozhuk, B G; Briskin, V R

    1985-01-01

    The authors studied the antiarrhythmic and antifibrillatory effects of the known antiarrhythmic agents and the new Soviet coronaroactive drug phenicaberan exhibiting an antiarrhythmic action. All the drugs were examined for side effects and the action on the central and intracardiac hemodynamics in patients with acute myocardial infarction. Recommendations have been given as to the choice of effective drugs for the prophylaxis of arrhythmias depending on the pattern of heart rhythm abnormality and the hemodynamics.

  20. [Ventricular tachycardia in a patient with rate-responsive cardiac pacemaker].

    PubMed

    Himbert, C; Lascault, G; Tonet, J; Coutte, R; Busquet, P; Frank, R; Grosgogeat, Y

    1992-11-01

    The authors report a case of syncopal ventricular tachycardia in a patient with a respiratory-dependent rate responsive pacemaker, followed-up for valvular heart disease with severe left ventricular dysfunction and sustained atrial and ventricular arrhythmias. The introduction of low dose betablocker therapy with reinforcement of the treatment of cardiac failure controlled the ventricular arrhythmia, after suppression of the data responsive function had been shown to be ineffective. The authors discuss the role of the rate responsive function in the triggering of the ventricular tachycardias.

Top