Sample records for facilities land treatment

  1. Aircraft Landing Dynamics Facility - A unique facility with new capabilities

    NASA Technical Reports Server (NTRS)

    Davis, P. A.; Stubbs, S. M.; Tanner, J. A.

    1985-01-01

    The Aircraft Landing Dynamics Facility (ALDF), formerly called the Landing Loads Track, is described. The paper gives a historical overview of the original NASA Langley Research Center Landing Loads Track and discusses the unique features of this national test facility. Comparisons are made between the original track characteristics and the new capabilities of the Aircraft Landing Dynamics Facility following the recently completed facility update. Details of the new propulsion and arresting gear systems are presented along with the novel features of the new high-speed carriage. The data acquisition system is described and the paper concludes with a review of future test programs.

  2. Land cover and topography affect the land transformation caused by wind facilities

    USGS Publications Warehouse

    Diffendorfer, Jay E.; Compton, Roger W.

    2014-01-01

    Land transformation (ha of surface disturbance/MW) associated with wind facilities shows wide variation in its reported values. In addition, no studies have attempted to explain the variation across facilities. We digitized land transformation at 39 wind facilities using high resolution aerial imagery. We then modeled the effects of turbine size, configuration, land cover, and topography on the levels of land transformation at three spatial scales. The scales included strings (turbines with intervening roads only), sites (strings with roads connecting them, buried cables and other infrastructure), and entire facilities (sites and the roads or transmission lines connecting them to existing infrastructure). An information theoretic modeling approach indicated land cover and topography were well-supported variables affecting land transformation, but not turbine size or configuration. Tilled landscapes, despite larger distances between turbines, had lower average land transformation, while facilities in forested landscapes generally had the highest land transformation. At site and string scales, flat topographies had the lowest land transformation, while facilities on mesas had the largest. The results indicate the landscape in which the facilities are placed affects the levels of land transformation associated with wind energy. This creates opportunities for optimizing wind energy production while minimizing land cover change. In addition, the results indicate forecasting the impacts of wind energy on land transformation should include the geographic variables affecting land transformation reported here.

  3. Land Cover and Topography Affect the Land Transformation Caused by Wind Facilities

    PubMed Central

    Diffendorfer, Jay E.; Compton, Roger W.

    2014-01-01

    Land transformation (ha of surface disturbance/MW) associated with wind facilities shows wide variation in its reported values. In addition, no studies have attempted to explain the variation across facilities. We digitized land transformation at 39 wind facilities using high resolution aerial imagery. We then modeled the effects of turbine size, configuration, land cover, and topography on the levels of land transformation at three spatial scales. The scales included strings (turbines with intervening roads only), sites (strings with roads connecting them, buried cables and other infrastructure), and entire facilities (sites and the roads or transmission lines connecting them to existing infrastructure). An information theoretic modeling approach indicated land cover and topography were well-supported variables affecting land transformation, but not turbine size or configuration. Tilled landscapes, despite larger distances between turbines, had lower average land transformation, while facilities in forested landscapes generally had the highest land transformation. At site and string scales, flat topographies had the lowest land transformation, while facilities on mesas had the largest. The results indicate the landscape in which the facilities are placed affects the levels of land transformation associated with wind energy. This creates opportunities for optimizing wind energy production while minimizing land cover change. In addition, the results indicate forecasting the impacts of wind energy on land transformation should include the geographic variables affecting land transformation reported here. PMID:24558449

  4. NASA Langley's Aircraft Landing Dynamics Facility

    NASA Technical Reports Server (NTRS)

    Davis, Pamela A.

    1993-01-01

    The Aircraft Landing Dynamics Facility (ALDF) is a unique facility with the ability to test aircraft landing gear systems on actual runway surfaces at operational ground speeds and loading conditions. A brief historical overview of the original Landing Loads Track (LLT) is given, followed by a detailed description of the new ALDF systems and operational capabilities.

  5. State waste discharge permit application for the 200 Area Effluent Treatment Facility and the State-Approved Land Disposal Site

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1993-08-01

    Application is being made for a permit pursuant to Chapter 173--216 of the Washington Administrative Code (WAC), to discharge treated waste water and cooling tower blowdown from the 200 Area Effluent Treatment Facility (ETF) to land at the State-Approved Land Disposal Site (SALDS). The ETF is located in the 200 East Area and the SALDS is located north of the 200 West Area. The ETF is an industrial waste water treatment plant that will initially receive waste water from the following two sources, both located in the 200 Area on the Hanford Site: (1) the Liquid Effluent Retention Facility (LERF)more » and (2) the 242-A Evaporator. The waste water discharged from these two facilities is process condensate (PC), a by-product of the concentration of waste from DSTs that is performed in the 242-A Evaporator. Because the ETF is designed as a flexible treatment system, other aqueous waste streams generated at the Hanford Site may be considered for treatment at the ETF. The origin of the waste currently contained in the DSTs is explained in Section 2.0. An overview of the concentration of these waste in the 242-A Evaporator is provided in Section 3.0. Section 4.0 describes the LERF, a storage facility for process condensate. Attachment A responds to Section B of the permit application and provides an overview of the processes that generated the wastes, storage of the wastes in double-shell tanks (DST), preliminary treatment in the 242-A Evaporator, and storage at the LERF. Attachment B addresses waste water treatment at the ETF (under construction) and the addition of cooling tower blowdown to the treated waste water prior to disposal at SALDS. Attachment C describes treated waste water disposal at the proposed SALDS.« less

  6. Lunar base launch and landing facilities conceptual design

    NASA Technical Reports Server (NTRS)

    Phillips, Paul G.; Simonds, Charles H.; Stump, William R.

    1992-01-01

    The purpose of this study was to perform a first look at the requirements for launch and landing facilities for early lunar bases and to prepared conceptual designs for some of these facilities. The emphasis of the study is on the facilities needed from the first manned landing until permanent occupancy, the Phase 2 lunar base. Factors including surface characteristics, navigation system, engine blast effects, and expected surface operations are used to develop landing pad designs, and definitions fo various other elements of the launch and landing facilities. Finally, the dependence of the use of these elements and the evolution of the facilities are established.

  7. Operation and Maintenance of Wastewater Treatment Facilities.

    ERIC Educational Resources Information Center

    Drury, Douglas D.

    1978-01-01

    Presents the 1978 literature review of wastewater treatment: (1) operators, training, and certification; (2) solutions to operating problems; (3) collection systems; (4) operations manuals; (5) wastewater treatment facility case histories; (5) land application; and (6) treatment of industrial wastes. A list of 36 references is also presented. (HM)

  8. Langley Aircraft Landing Dynamics Facility

    NASA Technical Reports Server (NTRS)

    Davis, Pamela A.; Stubbs, Sandy M.; Tanner, John A.

    1987-01-01

    The Langley Research Center has recently upgraded the Landing Loads Track (LLT) to improve the capability of low-cost testing of conventional and advanced landing gear systems. The unique feature of the Langley Aircraft Landing Dynamics Facility (ALDF) is the ability to test aircraft landing gear systems on actual runway surfaces at operational ground speeds and loading conditions. A historical overview of the original LLT is given, followed by a detailed description of the new ALDF systems and operational capabilities.

  9. Lunar Landing Research Facility and Model at Night

    NASA Image and Video Library

    1969-06-20

    Lunar Landing Module photographed at night at the Lunar Landing Research Facility. Gantry facility 1297. Upright cockpit design lander over moonscape pavement at LLRF. 69-4872 was published in Winds of Change, 75th Anniversary Publication of NASA, P.88, by James Schultz.

  10. 10 CFR 61.81 - Tests at land disposal facilities.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 2 2011-01-01 2011-01-01 false Tests at land disposal facilities. 61.81 Section 61.81 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) LICENSING REQUIREMENTS FOR LAND DISPOSAL OF RADIOACTIVE WASTE Records, Reports, Tests, and Inspections § 61.81 Tests at land disposal facilities. (a) Each...

  11. 10 CFR 61.81 - Tests at land disposal facilities.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 2 2014-01-01 2014-01-01 false Tests at land disposal facilities. 61.81 Section 61.81 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) LICENSING REQUIREMENTS FOR LAND DISPOSAL OF RADIOACTIVE WASTE Records, Reports, Tests, and Inspections § 61.81 Tests at land disposal facilities. (a) Each...

  12. 10 CFR 61.81 - Tests at land disposal facilities.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 2 2012-01-01 2012-01-01 false Tests at land disposal facilities. 61.81 Section 61.81 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) LICENSING REQUIREMENTS FOR LAND DISPOSAL OF RADIOACTIVE WASTE Records, Reports, Tests, and Inspections § 61.81 Tests at land disposal facilities. (a) Each...

  13. Quality Assurance Project Plan for Closure of the Central Facilities Area Sewage Treatment Plant Lagoon 3 and Land Application Area

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lewis, Michael G.

    This quality assurance project plan describes the technical requirements and quality assurance activities of the environmental data collection/analyses operations to close Central Facilities Area Sewage treatment Plant Lagoon 3 and the land application area. It describes the organization and persons involved, the data quality objectives, the analytical procedures, and the specific quality control measures to be employed. All quality assurance project plan activities are implemented to determine whether the results of the sampling and monitoring performed are of the right type, quantity, and quality to satisfy the requirements for closing Lagoon 3 and the land application area.

  14. Lunar base launch and landing facility conceptual design, 2nd edition

    NASA Technical Reports Server (NTRS)

    1988-01-01

    This report documents the Lunar Base Launch and Landing Facility Conceptual Design study. The purpose of this study was to examine the requirements for launch and landing facilities for early lunar bases and to prepare conceptual designs for some of these facilities. The emphasis of this study is on the facilities needed from the first manned landing until permanent occupancy. Surface characteristics and flight vehicle interactions are described, and various facility operations are related. Specific recommendations for equipment, facilities, and evolutionary planning are made, and effects of different aspects of lunar development scenarios on facilities and operations are detailed. Finally, for a given scenario, a specific conceptual design is developed and presented.

  15. AERIAL OF SHUTTLE LANDING FACILITY [SLF] POURING CONCRETE ON RUNWAY

    NASA Technical Reports Server (NTRS)

    1975-01-01

    AERIAL OF SHUTTLE LANDING FACILITY [SLF] POURING CONCRETE ON RUNWAY KSC-375C-10036.32 108-KSC-375C-10036.32, P-21425, ARCHIVE-04501 Aerial oblique of Shuttle Landing Facility. Pouring concrete on runway. Direction North - Altitude 100'.

  16. AERIAL OF SHUTTLE LANDING FACILITY [SLF] SAFING AND PARKING AREA

    NASA Technical Reports Server (NTRS)

    1975-01-01

    AERIAL OF SHUTTLE LANDING FACILITY [SLF] SAFING AND PARKING AREA KSC-375C-0654.18 108-KSC-375C-654.18, P-18812, ARCHIVE-04493 Aerial oblique - safing and parking area, Shuttle Orbiter Landing Facility. Altitude 800' direction- west.

  17. 43 CFR 429.31 - What uses are prohibited on Reclamation land, facilities, and waterbodies?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... land, facilities, and waterbodies? 429.31 Section 429.31 Public Lands: Interior Regulations Relating to..., FACILITIES, AND WATERBODIES Prohibited and Unauthorized Uses of Reclamation Land, Facilities, and Waterbodies § 429.31 What uses are prohibited on Reclamation land, facilities, and waterbodies? (a) Reclamation...

  18. Land Treatment Digital Library

    USGS Publications Warehouse

    Pilliod, David S.; Welty, Justin L.

    2013-01-01

    The Land Treatment Digital Library (LTDL) was created by the U.S. Geological Survey to catalog legacy land treatment information on Bureau of Land Management lands in the western United States. The LTDL can be used by federal managers and scientists for compiling information for data-calls, producing maps, generating reports, and conducting analyses at varying spatial and temporal scales. The LTDL currently houses thousands of treatments from BLM lands across 10 states. Users can browse a map to find information on individual treatments, perform more complex queries to identify a set of treatments, and view graphs of treatment summary statistics.

  19. Land Treatment Digital Library

    USGS Publications Warehouse

    Pilliod, David S.

    2009-01-01

    Across the country, public land managers make hundreds of decisions each year that influence landscapes and ecosystems within the lands they manage. Many of these decisions involve vegetation manipulations known as land treatments. Land treatments include activities such as removal or alteration of plant biomass, seeding burned areas, and herbicide applications. Data on these land treatments are usually stored at local offices, and gathering information across large spatial areas can be difficult. There is a need to centralize and store treatment data for Federal agencies involved in land treatments because these data are useful to land managers for policy and management and to scientists for developing sampling designs and studies. The Land Treatment Digital Library (LTDL) was created by the U.S. Geological Survey (USGS) to catalog information about land treatments on Federal lands in the western United States for all interested parties. The flexible framework of the library allows for the storage of a wide variety of data in different formats. The LTDL currently stores previously established land treatments or what often are called legacy data. The project was developed and has been refined based on feedback from partner agencies and stakeholders, with opportunity for the library holdings to expand as new information becomes available. The library contains data in text, tabular, spatial, and image formats. Specific examples include project plans and implementation reports, monitoring data, spatial data files from geographic information systems, digitized paper maps, and digital images of land treatments. The data are entered by USGS employees and are accessible through a searchable web site. The LTDL can be used to respond to information requests, conduct analyses and other forms of information syntheses, produce maps, and generate reports for DOI managers and scientists and other authorized users.

  20. AERIAL OF SHUTTLE LANDING FACILITY [SLF] RUNWAY CONSTRUCTION

    NASA Technical Reports Server (NTRS)

    1974-01-01

    AERIAL OF SHUTTLE LANDING FACILITY [SLF] RUNWAY CONSTRUCTION KSC-374C-10236.33 108-KSC-374C-10236.33, P-15911, ARCHIVE-04477 Shuttle runway facility construction progress - oblique vertical, altitude 3,000 ft. time 1030 - direction south - south half from center.

  1. Lunar launch and landing facilities and operations

    NASA Technical Reports Server (NTRS)

    1987-01-01

    The Florida Institute of Technology established an Interdisciplinary Design Team to design a lunar based facility whose primary function involves launch and landing operations for future moon missions. Both manned and unmanned flight operations were considered in the study with particular design emphasis on the utilization (or reutilization) of all materials available on the moon. This resource availability includes man-made materials which might arrive in the form of expendable landing vehicles as well as in situ lunar minerals. From an engineering standpoint, all such materials are considered as to their suitability for constructing new lunar facilities and/or repairing or expanding existing structures. Also considered in this design study was a determination of the feasibility of using naturally occurring lunar materials to provide fuel components to support lunar launch operations. Conventional launch and landing operations similar to those used during the Apollo Program were investigated as well as less conventional techniques such as rail guns and electromagnetic mass drivers. The Advanced Space Design team consisted of students majoring in Physics and Space Science as well as Electrical, Mechanical, Chemical and Ocean Engineering.

  2. 43 CFR 429.33 - What are the consequences for using Reclamation land, facilities, and waterbodies without...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Reclamation land, facilities, and waterbodies without authorization? 429.33 Section 429.33 Public Lands... BUREAU OF RECLAMATION LAND, FACILITIES, AND WATERBODIES Prohibited and Unauthorized Uses of Reclamation Land, Facilities, and Waterbodies § 429.33 What are the consequences for using Reclamation land...

  3. AERIAL OF SHUTTLE LANDING FACILITY [SLF] POURING OF CONCRETE

    NASA Technical Reports Server (NTRS)

    1975-01-01

    AERIAL OF SHUTTLE LANDING FACILITY [SLF] POURING OF CONCRETE KSC-375C-10036.31 108-KSC-375C-10036.31, P-21426, ARCHIVE-04502 Aerial oblique of Shuttle runway facilities. Pouring concrete on runway. Direction north - altitude 100'.

  4. 2012 Annual Wastewater Reuse Report for the Idaho National Laboratory Site's Central facilities Area Sewage Treatment Plant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mike Lewis

    2013-02-01

    This report describes conditions, as required by the state of Idaho Wastewater Reuse Permit (#LA-000141-03), for the wastewater land application site at Idaho National Laboratory Site’s Central Facilities Area Sewage Treatment Plant from November 1, 2011, through October 31, 2012. The report contains the following information: • Site description • Facility and system description • Permit required monitoring data and loading rates • Status of compliance conditions and activities • Discussion of the facility’s environmental impacts. During the 2012 permit year, no wastewater was land-applied to the irrigation area of the Central Facilities Area Sewage Treatment Plant.

  5. 10 CFR 61.82 - Commission inspections of land disposal facilities.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 2 2012-01-01 2012-01-01 false Commission inspections of land disposal facilities. 61.82 Section 61.82 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) LICENSING REQUIREMENTS FOR LAND DISPOSAL OF RADIOACTIVE WASTE Records, Reports, Tests, and Inspections § 61.82 Commission inspections of land disposal...

  6. 10 CFR 61.82 - Commission inspections of land disposal facilities.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 2 2014-01-01 2014-01-01 false Commission inspections of land disposal facilities. 61.82 Section 61.82 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) LICENSING REQUIREMENTS FOR LAND DISPOSAL OF RADIOACTIVE WASTE Records, Reports, Tests, and Inspections § 61.82 Commission inspections of land disposal...

  7. 10 CFR 61.82 - Commission inspections of land disposal facilities.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 2 2011-01-01 2011-01-01 false Commission inspections of land disposal facilities. 61.82 Section 61.82 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) LICENSING REQUIREMENTS FOR LAND DISPOSAL OF RADIOACTIVE WASTE Records, Reports, Tests, and Inspections § 61.82 Commission inspections of land disposal...

  8. STS-112 Atlantis landing at KSC's shuttle landing facility

    NASA Technical Reports Server (NTRS)

    2002-01-01

    KENNEDY SPACE CENTER, FLA. -- Space Shuttle Atlantis approaches the runway at the Shuttle Landing Facility, completing the 4.5-million-mile journey to the International Space Station. Main gear touchdown occurred at 11:43:40 a.m. EDT; nose gear touchdown at 11:43:48 a.m.; and wheel stop at 11:44:35 a.m. Mission elapsed time was 10:19:58:44. Mission STS-112 expanded the size of the Station with the addition of the S1 truss segment. The returning crew of Atlantis are Commander Jeffrey Ashby, Pilot Pamela Melroy, and Mission Specialists David Wolf, Piers Sellers, Sandra Magnus and Fyodor Yurchikhin. This landing is the 60th at KSC in the history of the Shuttle program. .

  9. Lunar landing and launch facilities and operations

    NASA Technical Reports Server (NTRS)

    1988-01-01

    A preliminary design of a lunar landing and launch facility for a Phase 3 lunar base is formulated. A single multipurpose vehicle for the lunar module is assumed. Three traffic levels are envisioned: 6, 12, and 24 landings/launches per year. The facility is broken down into nine major design items. A conceptual description of each of these items is included. Preliminary sizes, capacities, and/or other relevant design data for some of these items are obtained. A quonset hut tent-like structure constructed of aluminum rods and aluminized mylar panels is proposed. This structure is used to provide a constant thermal environment for the lunar modules. A structural design and thermal analysis is presented. Two independent designs for a bridge crane to unload/load heavy cargo from the lunar module are included. Preliminary investigations into cryogenic propellant storage and handling, landing/launch guidance and control, and lunar module maintenance requirements are performed. Also, an initial study into advanced concepts for application to Phase 4 or 5 lunar bases has been completed in a report on capturing, condensing, and recycling the exhaust plume from a lunar launch.

  10. STS-112 Atlantis landing at KSC's shuttle landing facility

    NASA Technical Reports Server (NTRS)

    2002-01-01

    KENNEDY SPACE CENTER, FLA. -- Space Shuttle Atlantis stirs up dust as it touches down on Runway 33 at the Shuttle Landing Facility, completing the 4.5-million-mile journey to the International Space Station. Main gear touchdown occurred at 11:43:40 a.m. EDT; nose gear touchdown at 11:43:48 a.m.; and wheel stop at 11:44:35 a.m. Mission elapsed time was 10:19:58:44. Mission STS-112 expanded the size of the Station with the addition of the S1 truss segment. The returning crew of Atlantis are Commander Jeffrey Ashby, Pilot Pamela Melroy, and Mission Specialists David Wolf, Piers Sellers, Sandra Magnus and Fyodor Yurchikhin. This landing is the 60th at KSC in the history of the Shuttle program. .

  11. STS-112 Atlantis landing at KSC's shuttle landing facility

    NASA Technical Reports Server (NTRS)

    2002-01-01

    KENNEDY SPACE CENTER, FLA. -- Space Shuttle Atlantis casts a needle-shaped shadow as it drops to the runway at the Shuttle Landing Facility, completing the 4.5-million-mile journey to the International Space Station. Main gear touchdown occurred at 11:43:40 a.m. EDT; nose gear touchdown at 11:43:48 a.m.; and wheel stop at 11:44:35 a.m. Mission elapsed time was 10:19:58:44. Mission STS-112 expanded the size of the Station with the addition of the S1 truss segment. The returning crew of Atlantis are Commander Jeffrey Ashby, Pilot Pamela Melroy, and Mission Specialists David Wolf, Piers Sellers, Sandra Magnus and Fyodor Yurchikhin. This landing is the 60th at KSC in the history of the Shuttle program.

  12. Field Sampling Plan for Closure of the Central Facilities Area Sewage Treatment Plant Lagoon 3 and Land Application Area

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lewis, Michael George

    This field sampling plan describes sampling of the soil/liner of Lagoon 3 at the Central Facilities Area Sewage Treatment Plant. The lagoon is to be closed, and samples obtained from the soil/liner will provide information to determine if Lagoon 3 and the land application area can be closed in a manner that renders it safe to human health and the environment. Samples collected under this field sampling plan will be compared to Idaho National Laboratory background soil concentrations. If the concentrations of constituents of concern exceed the background level, they will be compared to Comprehensive Environmental Response, Compensation, and Liabilitymore » Act preliminary remediation goals and Resource Conservation and Recovery Act levels. If the concentrations of constituents of concern are lower than the background levels, Resource Conservation and Recovery Act levels, or the preliminary remediation goals, then Lagoon 3 and the land application area will be closed. If the Resource Conservation and Recovery Act levels and/or the Comprehensive Environmental Response, Compensation, and Liability Act preliminary remediation goals are exceeded, additional sampling and action may be required.« less

  13. 2011 Annual Wastewater Reuse Report for the Idaho National Laboratory Site’s Central Facilities Area Sewage Treatment Plant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Michael G. Lewis

    2012-02-01

    This report describes conditions, as required by the state of Idaho Wastewater Reuse Permit (LA-000141-03), for the wastewater land application site at Idaho National Laboratory Site's Central Facilities Area Sewage Treatment Plant from November 1, 2010, through October 31, 2011. The report contains the following information: (1) Site description; (2) Facility and system description; (3) Permit required monitoring data and loading rates; (4) Status of special compliance conditions and activities; and (5) Discussion of the facility's environmental impacts. During the 2011 permit year, approximately 1.22 million gallons of treated wastewater was land-applied to the irrigation area at Central Facilities Areamore » Sewage Treatment plant.« less

  14. 43 CFR 429.33 - What are the consequences for using Reclamation land, facilities, and waterbodies without...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 43 Public Lands: Interior 1 2010-10-01 2010-10-01 false What are the consequences for using Reclamation land, facilities, and waterbodies without authorization? 429.33 Section 429.33 Public Lands... Land, Facilities, and Waterbodies § 429.33 What are the consequences for using Reclamation land...

  15. AERIAL OF SHUTTLE LANDING FACILITY [SLF] RUNWAY AND PARKING APRON

    NASA Technical Reports Server (NTRS)

    1974-01-01

    AERIAL OF SHUTTLE LANDING FACILITY [SLF] RUNWAY AND PARKING APRON KSC-374C-10236.23 108-KSC-374C-10236.23, P-15909, ARCHIVE-04476 Shuttle runway facility construction progress - oblique vertical, altitude 1,000 ft. Time 1100 - direction E - Shuttle Park area.

  16. STS-69 Main Gear Touch Down at Shuttle Landing Facility

    NASA Technical Reports Server (NTRS)

    1995-01-01

    STS-69 Mission Commander David M. Walker guides the orbiter Endeavour to an end-of-mission landing on Runway 33 of KSC's Shuttle Landing Facility. Main gear touchdown at 7:37:56 a.m. EDT marked the 25th end-of-mission landing at Kennedy. The fifth Space Shuttle flight of 1995 was a multifaceted one. For the first time, two spacecraft -- the Wake Shield Facility-2 and the Spartan-201-3 -- were deployed and later retrieved on the same flight. An extravehicular activity, or spacewalk, was conducted and the crew oversaw a variety of experiments located in both the orbiter payload bay and middeck. Besides Walker, the crew included Pilot Kenneth D. Cockrell; Payload Commander James S. Voss; and Mission Specialists Michael L. Gernhardt and James H. Newman.

  17. 40 CFR 270.20 - Specific part B information requirements for land treatment facilities.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... field test that will be conducted, including: (i) The type of test (e.g., column leaching, degradation...: (1) The wastes to be land treated; (2) Design measures and operating practices necessary to maximize... treatment zone; (c) A description of how the unit is or will be designed, constructed, operated, and...

  18. 40 CFR 270.20 - Specific part B information requirements for land treatment facilities.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... field test that will be conducted, including: (i) The type of test (e.g., column leaching, degradation...: (1) The wastes to be land treated; (2) Design measures and operating practices necessary to maximize... treatment zone; (c) A description of how the unit is or will be designed, constructed, operated, and...

  19. 40 CFR 270.20 - Specific part B information requirements for land treatment facilities.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... field test that will be conducted, including: (i) The type of test (e.g., column leaching, degradation...: (1) The wastes to be land treated; (2) Design measures and operating practices necessary to maximize... treatment zone; (c) A description of how the unit is or will be designed, constructed, operated, and...

  20. 40 CFR 270.20 - Specific part B information requirements for land treatment facilities.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... field test that will be conducted, including: (i) The type of test (e.g., column leaching, degradation...: (1) The wastes to be land treated; (2) Design measures and operating practices necessary to maximize... treatment zone; (c) A description of how the unit is or will be designed, constructed, operated, and...

  1. Impact Landing Dynamics Facility Crash Test

    NASA Image and Video Library

    1975-08-03

    Photographed on: 08/03/75. -- By 1972 the Lunar Landing Research Facility was no longer in use for its original purpose. The 400-foot high structure was swiftly modified to allow engineers to study the dynamics of aircraft crashes. "The Impact Dynamics Research Facility is used to conduct crash testing of full-scale aircraft under controlled conditions. The aircraft are swung by cables from an A-frame structure that is approximately 400 ft. long and 230 foot high. The impact runway can be modified to simulate other grand crash environments, such as packed dirt, to meet a specific test requirement." "In 1972, NASA and the FAA embarked on a cooperative effort to develop technology for improved crashworthiness and passenger survivability in general aviation aircraft with little or no increase in weight and acceptable cost. Since then, NASA has "crashed" dozens of GA aircraft by using the lunar excursion module (LEM) facility originally built for the Apollo program." This photograph shows Crash Test No. 7. Crash Test: Test #7

  2. Neil Armstrong at Lunar Landing Research Facility

    NASA Image and Video Library

    1969-02-12

    Neil Armstrong with the Lunar Excursion Module (LEM). Caption: "Not long after this photo was taken in front of the Lunar Landing Research Facility, astronaut Neil Armstrong became the first human to step upon the surface of the Moon." Photograph published in Winds of Change, 75th Anniversary NASA publication, by James Schultz, page 91. Also published in " A Century at Langley" by Joseph Chambers, pg. 95

  3. Aerial view of the Shuttle Landing Facility

    NASA Technical Reports Server (NTRS)

    1998-01-01

    From the air over KSC can be seen the Shuttle Landing Facility. Orbiter landings at the Kennedy Space Center are made on one of the largest runways in the world. The runway is located 3.2 km (2 miles) northwest of the Vehicle Assembly Building and is 4,572 meters (15,000ft) long and 91.4 meters (300ft) wide -- about as wide as the length of a football field. It has 305 meters (1000ft) of paved overruns at each end and the paving thickness is 40.6cm (15 inches) at the center. At left in the photo is the Aircraft Ground Equipment Shed; in the center is the Landing Aids Control Building (LACB) which supports landing operations and houses operations personnel. Located at the northeast corner of the parking apron is the Mate/Demate device (MDD) used to raise and lower the orbiter from its 747 carrier aircraft during ferry operations. The open-truss steel structure is equipped with hoists, adapters and movable platforms for access to certain orbiter components and equipment. It also is equipped with lightning protection devices. The MDD is 45.7 meters (150ft) long, 28.3 meters (93ft) wide and 32 meters (105ft) high. On the landing area in front of the SLF is a T-38 jet airplane.

  4. Preliminary definition of a lunar landing and launch facility (Complex 39L)

    NASA Technical Reports Server (NTRS)

    Matthews, H. Dennis; Jenson, Eric B.; Linsley, Jerald N.

    1992-01-01

    A preliminary definition of a lunar landing and launch facility has been formulated. A permanently manned lunar base and a baseline lunar module are assumed. The major features of the facility are specified and major design areas are described.

  5. 2013 Annual Wastewater Reuse Report for the Idaho National Laboratory Site’s Central Facilities Area Sewage Treatment Plant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mike Lewis

    2014-02-01

    This report describes conditions, as required by the state of Idaho Wastewater Reuse Permit (#LA-000141-03), for the wastewater land application site at the Idaho National Laboratory Site’s Central Facilities Area Sewage Treatment Plant from November 1, 2012, through October 31, 2013. The report contains, as applicable, the following information: • Site description • Facility and system description • Permit required monitoring data and loading rates • Status of compliance conditions and activities • Discussion of the facility’s environmental impacts. During the 2013 permit year, no wastewater was land-applied to the irrigation area of the Central Facilities Area Sewage Treatment Plantmore » and therefore, no effluent flow volumes or samples were collected from wastewater sampling point WW-014102. However, soil samples were collected in October from soil monitoring unit SU-014101.« less

  6. BIOREMEDIATION USING THE LAND TREATMENT CONCEPT

    EPA Science Inventory

    This document is designed to be used by those who are involved with the use of land treatment technologies for the remediation of contaminated solid phase materials. In addition to a discussion of the basic processes which drive land treatment applications, the parameters involv...

  7. Aerial views of construction on the RLV hangar at the Shuttle Landing Facility

    NASA Technical Reports Server (NTRS)

    1999-01-01

    Looking southwest, this view shows ongoing construction of a multi-purpose hangar, which is part of the $8 million Reusable Launch Vehicle (RLV) Support Complex at Kennedy Space Center. Edging the construction is Sharkey Road, which parallels the landing strip of the Shuttle Landing Facility nearby. The RLV complex will include facilities for related ground support equipment and administrative/ technical support. It will be available to accommodate the Space Shuttle; the X-34 RLV technology demonstrator; the L-1011 carrier aircraft for Pegasus and X-34; and other RLV and X-vehicle programs. The complex is jointly funded by the Spaceport Florida Authority, NASA's Space Shuttle Program and KSC. The facility will be operational in early 2000.

  8. 32 CFR 766.6 - Approving authority for landings at Navy/Marine Corps aviation facilities.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Corps aviation facilities. 766.6 Section 766.6 National Defense Department of Defense (Continued) DEPARTMENT OF THE NAVY MISCELLANEOUS RULES USE OF DEPARTMENT OF THE NAVY AVIATION FACILITIES BY CIVIL AIRCRAFT § 766.6 Approving authority for landings at Navy/Marine Corps aviation facilities. (a) Except as...

  9. 32 CFR 766.6 - Approving authority for landings at Navy/Marine Corps aviation facilities.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Corps aviation facilities. 766.6 Section 766.6 National Defense Department of Defense (Continued) DEPARTMENT OF THE NAVY MISCELLANEOUS RULES USE OF DEPARTMENT OF THE NAVY AVIATION FACILITIES BY CIVIL AIRCRAFT § 766.6 Approving authority for landings at Navy/Marine Corps aviation facilities. (a) Except as...

  10. 32 CFR 766.6 - Approving authority for landings at Navy/Marine Corps aviation facilities.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Corps aviation facilities. 766.6 Section 766.6 National Defense Department of Defense (Continued) DEPARTMENT OF THE NAVY MISCELLANEOUS RULES USE OF DEPARTMENT OF THE NAVY AVIATION FACILITIES BY CIVIL AIRCRAFT § 766.6 Approving authority for landings at Navy/Marine Corps aviation facilities. (a) Except as...

  11. 32 CFR 766.6 - Approving authority for landings at Navy/Marine Corps aviation facilities.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Corps aviation facilities. 766.6 Section 766.6 National Defense Department of Defense (Continued) DEPARTMENT OF THE NAVY MISCELLANEOUS RULES USE OF DEPARTMENT OF THE NAVY AVIATION FACILITIES BY CIVIL AIRCRAFT § 766.6 Approving authority for landings at Navy/Marine Corps aviation facilities. (a) Except as...

  12. 32 CFR 766.6 - Approving authority for landings at Navy/Marine Corps aviation facilities.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Corps aviation facilities. 766.6 Section 766.6 National Defense Department of Defense (Continued) DEPARTMENT OF THE NAVY MISCELLANEOUS RULES USE OF DEPARTMENT OF THE NAVY AVIATION FACILITIES BY CIVIL AIRCRAFT § 766.6 Approving authority for landings at Navy/Marine Corps aviation facilities. (a) Except as...

  13. Construction continues on the RLV complex at the Shuttle Landing Facility

    NASA Technical Reports Server (NTRS)

    1999-01-01

    At the construction site of the Reusable Launch Vehicle (RLV) complex at KSC, a worker takes a measurement. Located near the Shuttle Landing Facility, the complex will include facilities for related ground support equipment and administrative/ technical support. It will be available to accommodate the Space Shuttle; the X-34 RLV technology demonstrator; the L-1011 carrier aircraft for Pegasus and X-34; and other RLV and X-vehicle programs. The complex is jointly funded by the Spaceport Florida Authority, NASA's Space Shuttle Program and KSC. The facility will be operational in early 2000.

  14. Construction continues on the RLV complex at the Shuttle Landing Facility

    NASA Technical Reports Server (NTRS)

    1999-01-01

    Construction is under way for the X-33/X-34 hangar complex near the Shuttle Landing Facility at KSC. The Reusable Launch Vehicle (RLV) complex will include facilities for related ground support equipment and administrative/ technical support. It will be available to accommodate the Space Shuttle; the X-34 RLV technology demonstrator; the L-1011 carrier aircraft for Pegasus and X-34; and other RLV and X-vehicle programs. The complex is jointly funded by the Spaceport Florida Authority, NASA's Space Shuttle Program and KSC. The facility will be operational in early 2000.

  15. Land developer participation in providing for bus transit facilities and operations

    DOT National Transportation Integrated Search

    2002-03-01

    This report provides an overview of the various non-regulatory and regulatory approaches for engaging private sector land developer participation in contributing toward the provision of public bus transit capital facilities and the cost of operations...

  16. Construction continues on the RLV complex at the Shuttle Landing Facility

    NASA Technical Reports Server (NTRS)

    1999-01-01

    At the construction site of the Reusable Launch Vehicle (RLV) complex at KSC, workers take measurements for one of the buildings. Located near the Shuttle Landing Facility, the complex will include facilities for related ground support equipment and administrative/ technical support. It will be available to accommodate the Space Shuttle; the X-34 RLV technology demonstrator; the L-1011 carrier aircraft for Pegasus and X-34; and other RLV and X-vehicle programs. The complex is jointly funded by the Spaceport Florida Authority, NASA's Space Shuttle Program and KSC. The facility will be operational in early 2000.

  17. Flood risk assessment of land pollution hotspots

    NASA Astrophysics Data System (ADS)

    Masi, Matteo; Arrighi, Chiara; Iannelli, Renato

    2017-04-01

    Among the risks caused by extreme events, the potential spread of pollutants stored in land hotspots due to floods is an aspect that has been rarely examined with a risk-based approach. In this contribution, an attempt to estimate pollution risks related to flood events of land pollution hotspots was carried out. Flood risk has been defined as the combination of river flood hazard, hotspots exposure and vulnerability to contamination of the area, i.e. the expected severity of the environmental impacts. The assessment was performed on a geographical basis, using geo-referenced open data, available from databases of land management institutions, authorities and agencies. The list of land pollution hotspots included landfills and other waste handling facilities (e.g., temporary storage, treatment and recycling sites), municipal wastewater treatment plants, liquid waste treatment facilities and contaminated sites. The assessment was carried out by combining geo-referenced data of pollution hotspots with flood hazard maps. We derived maps of land pollution risk based on geographical and geological properties and source characteristics available from environmental authorities. These included information about soil particle size, soil hydraulic conductivity, terrain slope, type of stored pollutants, the type of facility, capacity, size of the area, land use, etc. The analysis was carried out at catchment scale. The case study of the Arno river basin in Tuscany (central Italy) is presented.

  18. Systematic Review of Multidisciplinary Chronic Pain Treatment Facilities

    PubMed Central

    Fashler, Samantha R.; Cooper, Lynn K.; Oosenbrug, Eric D.; Burns, Lindsay C.; Razavi, Shima; Goldberg, Lauren; Katz, Joel

    2016-01-01

    This study reviewed the published literature evaluating multidisciplinary chronic pain treatment facilities to provide an overview of their availability, caseload, wait times, and facility characteristics. A systematic literature review was conducted using PRISMA guidelines following a search of MEDLINE, PsycINFO, and CINAHL databases. Inclusion criteria stipulated that studies be original research, survey more than one pain treatment facility directly, and describe a range of available treatments. Fourteen articles satisfied inclusion criteria. Results showed little consistency in the research design used to describe pain treatment facilities. Availability of pain treatment facilities was scarce and the reported caseloads and wait times were generally high. A wide range of medical, physical, and psychological pain treatments were available. Most studies reported findings on the percentage of practitioners in different health care professions employed. Future studies should consider using more comprehensive search strategies to survey facilities, improving clarity on what is considered to be a pain treatment facility, and reporting on a consistent set of variables to provide a clear summary of the status of pain treatment facilities. This review highlights important information for policymakers on the scope, demand, and accessibility of pain treatment facilities. PMID:27445618

  19. STS-95: Post Landing and Crew Walkaround of the Orbiter at the Shuttle Landing Facility

    NASA Technical Reports Server (NTRS)

    1998-01-01

    After landing, the STS-95 crew (Commander Curtis L. Brown, Pilot Steven W. Lindsey, Mission Specialists Scott E. Parazynski, Stephen K. Robinson, Pedro Duque, Payload Specialists Chiaki Mukai and the legendary John H. Glenn) descend from the Space Shuttle. Commander Brown congratulates the crew and team photos are taken. The crew does a walkaround inspection of the spacecraft, then boards the bus for departure from the facility.

  20. 2015 Annual Wastewater Reuse Report for the Idaho National Laboratory Site’s Central Facilities Area Sewage Treatment Plant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lewis, Michael George

    This report describes conditions, as required by the state of Idaho Wastewater Reuse Permit (#LA-000141-03), for the wastewater land application site at the Idaho National Laboratory Site’s Central Facilities Area Sewage Treatment Plant from November 1, 2014, through October 31, 2015.

  1. Probabilistic Modeling of Settlement Risk at Land Disposal Facilities - 12304

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Foye, Kevin C.; Soong, Te-Yang

    2012-07-01

    The long-term reliability of land disposal facility final cover systems - and therefore the overall waste containment - depends on the distortions imposed on these systems by differential settlement/subsidence. The evaluation of differential settlement is challenging because of the heterogeneity of the waste mass (caused by inconsistent compaction, void space distribution, debris-soil mix ratio, waste material stiffness, time-dependent primary compression of the fine-grained soil matrix, long-term creep settlement of the soil matrix and the debris, etc.) at most land disposal facilities. Deterministic approaches to long-term final cover settlement prediction are not able to capture the spatial variability in the wastemore » mass and sub-grade properties which control differential settlement. An alternative, probabilistic solution is to use random fields to model the waste and sub-grade properties. The modeling effort informs the design, construction, operation, and maintenance of land disposal facilities. A probabilistic method to establish design criteria for waste placement and compaction is introduced using the model. Random fields are ideally suited to problems of differential settlement modeling of highly heterogeneous foundations, such as waste. Random fields model the seemingly random spatial distribution of a design parameter, such as compressibility. When used for design, the use of these models prompts the need for probabilistic design criteria. It also allows for a statistical approach to waste placement acceptance criteria. An example design evaluation was performed, illustrating the use of the probabilistic differential settlement simulation methodology to assemble a design guidance chart. The purpose of this design evaluation is to enable the designer to select optimal initial combinations of design slopes and quality control acceptance criteria that yield an acceptable proportion of post-settlement slopes meeting some design minimum. For this

  2. Atmospheric characterization on the Kennedy Space Center Shuttle Landing Facility

    NASA Astrophysics Data System (ADS)

    Ko, Jonathan; Coffaro, Joseph; Wu, Chensheng; Paulson, Daniel; Davis, Christopher

    2017-08-01

    Large temperature gradients are a known source of strong atmospheric turbulence conditions. Often times these areas of strong turbulence conditions are also accompanied by conditions that make it difficult to conduct long term optical atmospheric tests. The Shuttle Landing Facility (SLF) at the Kennedy Space Center (KSC) provides a prime testing environment that is capable of generating strong atmospheric turbulence yet is also easily accessible for well instrumented testing. The Shuttle Landing Facility features a 5000 m long and 91 m wide concrete runway that provides ample space for measurements of atmospheric turbulence as well as the opportunity for large temperature gradients to form as the sun heats the surface. We present the results of a large aperture LED scintillometer, a triple aperture laser scintillometer, and a thermal probe system that were used to calculate a path averaged and a point calculation of Cn2. In addition, we present the results of the Plenoptic Sensor that was used to calculate a path averaged Cn2 value. These measurements were conducted over a multi-day continuous test with supporting atmospheric and weather data provided by the University of Central Florida.

  3. Texture Modification of the Shuttle Landing Facility Runway at the NASA Kennedy Space Center

    NASA Technical Reports Server (NTRS)

    Daugherty, Robert H.; Yager, Thomas J.

    1996-01-01

    This paper describes the test procedures and the selection criteria used in selecting the best runway surface texture modification at the Kennedy Space Center (KSC) Shuttle Landing Facility (SLF) to reduce Orbiter tire wear. The new runway surface may ultimately result in an increase of allowable crosswinds for launch and landing operations. The modification allows launch and landing operations in 20-kt crosswinds if desired. This 5-kt increase over the previous 15-kt limit drastically increases landing safety and the ability to make on-time launches to support missions where space station rendezvous is planned.

  4. Hanford Facility dangerous waste permit application, liquid effluent retention facility and 200 area effluent treatment facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Coenenberg, J.G.

    1997-08-15

    The Hanford Facility Dangerous Waste Permit Application is considered to 10 be a single application organized into a General Information Portion (document 11 number DOE/RL-91-28) and a Unit-Specific Portion. The scope of the 12 Unit-Specific Portion is limited to Part B permit application documentation 13 submitted for individual, `operating` treatment, storage, and/or disposal 14 units, such as the Liquid Effluent Retention Facility and 200 Area Effluent 15 Treatment Facility (this document, DOE/RL-97-03). 16 17 Both the General Information and Unit-Specific portions of the Hanford 18 Facility Dangerous Waste Permit Application address the content of the Part B 19 permit applicationmore » guidance prepared by the Washington State Department of 20 Ecology (Ecology 1987 and 1996) and the U.S. Environmental Protection Agency 21 (40 Code of Federal Regulations 270), with additional information needs 22 defined by the Hazardous and Solid Waste Amendments and revisions of 23 Washington Administrative Code 173-303. For ease of reference, the Washington 24 State Department of Ecology alpha-numeric section identifiers from the permit 25 application guidance documentation (Ecology 1996) follow, in brackets, the 26 chapter headings and subheadings. A checklist indicating where information is 27 contained in the Liquid Effluent Retention Facility and 200 Area Effluent 28 Treatment Facility permit application documentation, in relation to the 29 Washington State Department of Ecology guidance, is located in the Contents 30 Section. 31 32 Documentation contained in the General Information Portion is broader in 33 nature and could be used by multiple treatment, storage, and/or disposal units 34 (e.g., the glossary provided in the General Information Portion). Wherever 35 appropriate, the Liquid Effluent Retention Facility and 200 Area Effluent 36 Treatment Facility permit application documentation makes cross-reference to 37 the General Information Portion, rather than

  5. Sample Federal Facility Land Use Control ROD Checklist and Suggested Language (LUC Checklist)

    EPA Pesticide Factsheets

    The LUC Checklist provides direction on describing and documenting land use controls (LUCs) in federal facility actrions under CERCLA in Records of Decision (RODs), remedial designs (RDs), and remedial action work plans (RAWPs).

  6. Effects of land use and municipal wastewater treatment changes on stream water quality.

    PubMed

    Ha, S R; Bae, M S

    2001-07-01

    This study was undertaken to analyze the quantitative impact of a municipal wastewater treatment operation on the long-term water quality changes in a tributary of the Han-river, Korea from 1994 to 1999. Changes of land use pattern in the study watershed are quantitatively analyzed on the basis of land use maps that were created by classifying Landsat TM images acquired in April 1994 and March 1999. During this period, the average increase of land use area in terms of residence, cultivation, and barren was 5.89, 0.13, and 0.12%, respectively, and the corresponding decrease in water and forest area was 0.21 and 0.16%. The annual average reductions of BOD, T-N, and T-P by the municipal wastewater treatment operation were about 89, 11 and 27%, respectively. Spatial analysis of the pollution discharge from watershed was undertaken using a geographic information system (GIS) based model. A clear reciprocal relationship was found between the basin-wide self-purification coefficient and the watershed form ratio excepting a catchment area with water drain facilities. Due to land use changes over the five year study period, water quality change in terms of BOD, T-N, and T-P were (+)1.04 mg l(-1) (corresponding to a 13.7% increase of pollution), (+)0.58 mgl(-1) (10.0% increase), and (-)0.01 mg l(-1) (1.6% decrease). On the other hand, the effect of water quality restoration assessed by outward appearance during the same period was about 67.6, 39, and 36.5%, respectively. Consequently, it is understood that total stream water quality recovery in terms of BOD, T-N, and T-P were 81.3, 49.0, and 38.1% respectively, and that this included a negative contribution resulting from increased land use and a positive contribution due to the wastewater treatment operation at Inchon.

  7. Winery wastewater treatment using the land filter technique.

    PubMed

    Christen, E W; Quayle, W C; Marcoux, M A; Arienzo, M; Jayawardane, N S

    2010-08-01

    This study outlines a new approach to the treatment of winery wastewater by application to a land FILTER (Filtration and Irrigated cropping for Land Treatment and Effluent Reuse) system. The land FILTER system was tested at a medium size rural winery crushing approximately 20,000 tonnes of grapes. The approach consisted of a preliminary treatment through a coarse screening and settling in treatment ponds, followed by application to the land FILTER planted to pasture. The land FILTER system efficiently dealt with variable volumes and nutrient loads in the wastewater. It was operated to minimize pollutant loads in the treated water (subsurface drainage) and provide adequate leaching to manage salt in the soil profile. The land FILTER system was effective in neutralizing the pH of the wastewater and removing nutrient pollutants to meet EPA discharge limits. However, suspended solids (SS) and biological oxygen demand (BOD) levels in the subsurface drainage waters slightly exceeded EPA limits for discharge. The high organic content in the wastewater initially caused some soil blockage and impeded drainage in the land FILTER site. This was addressed by reducing the hydraulic loading rate to allow increased soil drying between wastewater irrigations. The analysis of soil characteristics after the application of wastewater found that there was some potassium accumulation in the profile but sodium and nutrients decreased after wastewater application. Thus, the wastewater application and provision of subsurface drainage ensured adequate leaching, and so was adequate to avoid the risk of soil salinisation. Crown Copyright 2010. Published by Elsevier Ltd. All rights reserved.

  8. Climate Adaptation Capacity for Conventional Drinking Water Treatment Facilities

    NASA Astrophysics Data System (ADS)

    Levine, A.; Goodrich, J.; Yang, J.

    2013-12-01

    Water supplies are vulnerable to a host of climate- and weather-related stressors such as droughts, intense storms/flooding, snowpack depletion, sea level changes, and consequences from fires, landslides, and excessive heat or cold. Surface water resources (lakes, reservoirs, rivers, and streams) are especially susceptible to weather-induced changes in water availability and quality. The risks to groundwater systems may also be significant. Typically, water treatment facilities are designed with an underlying assumption that water quality from a given source is relatively predictable based on historical data. However, increasing evidence of the lack of stationarity is raising questions about the validity of traditional design assumptions, particularly since the service life of many facilities can exceed fifty years. Given that there are over 150,000 public water systems in the US that deliver drinking water to over 300 million people every day, it is important to evaluate the capacity for adapting to the impacts of a changing climate. Climate and weather can induce or amplify changes in physical, chemical, and biological water quality, reaction rates, the extent of water-sediment-air interactions, and also impact the performance of treatment technologies. The specific impacts depend on the watershed characteristics and local hydrological and land-use factors. Water quality responses can be transient, such as erosion-induced increases in sediment and runoff. Longer-term impacts include changes in the frequency and intensity of algal blooms, gradual changes in the nature and concentration of dissolved organic matter, dissolved solids, and modulation of the microbiological community structure, sources and survival of pathogens. In addition, waterborne contaminants associated with municipal, industrial, and agricultural activities can also impact water quality. This presentation evaluates relationships between climate and weather induced water quality variability and

  9. 2014 Annual Wastewater Reuse Report for the Idaho National Laboratory Site’s Central Facilities Area Sewage Treatment Plant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lewis, Mike

    This report describes conditions, as required by the state of Idaho Wastewater Reuse Permit (#LA-000141-03), for the wastewater land application site at the Idaho National Laboratory Site’s Central Facilities Area Sewage Treatment Plant from November 1, 2013, through October 31, 2014. The report contains, as applicable, the following information; Site description; Facility and system description; Permit required monitoring data and loading rates; Status of compliance conditions and activities; and Discussion of the facility’s environmental impacts. The current permit expires on March 16, 2015. A permit renewal application was submitted to Idaho Department of Environmental Quality on September 15, 2014. Duringmore » the 2014 permit year, no wastewater was land-applied to the irrigation area of the Central Facilities Area Sewage Treatment Plant and therefore, no effluent flow volumes or samples were collected from wastewater sampling point WW-014102. Seepage testing of the three lagoons was performed between August 26, 2014 and September 22, 2014. Seepage rates from Lagoons 1 and 2 were below the 0.25 inches/day requirement; however, Lagoon 3 was above the 0.25 inches/day. Lagoon 3 has been isolated and is being evaluated for future use or permanent removal from service.« less

  10. Forest land application of municipal sludge.

    Treesearch

    D.G. Brockway

    1988-01-01

    In Michigan, 199 municipal and numerous industrial wastewater treatment facilities annually generate 222,750 dry tons of sludge, most of which is recycled on farmland. Substantial potential exists, however, to increase application on forest land in the northern two-thirds of the state (Brockway and Nguyen 1986). Although sludge application on agricultural land has...

  11. Potable Water Treatment Facility General Permit (PWTF GP) ...

    EPA Pesticide Factsheets

    2017-08-28

    The Final PWTF GP establishes permit eligibility conditions, Notice of Intent (NOI) requirements, effluent limitations, standards, prohibitions, and best management practices for facilities that discharge to waters in the Commonwealth of Massachusetts (including both Commonwealth and Indian country lands) and the State of New Hampshire.

  12. Shuttle Flight Operations Contract Generator Maintenance Facility Land Use Control Implementation Plan (LUCIP)

    NASA Technical Reports Server (NTRS)

    Applegate, Joseph L.

    2014-01-01

    This Land Use Control Implementation Plan (LUCIP) has been prepared to inform current and potential future users of the Kennedy Space Center (KSC) Shuttle Flight Operations Contract Generator Maintenance Facility (SFOC; SWMU 081; "the Site") of institutional controls that have been implemented at the Site1. Although there are no current unacceptable risks to human health or the environment associated with the SFOC, an institutional land use control (LUC) is necessary to prevent human health exposure to antimony-affected groundwater at the Site. Controls will include periodic inspection, condition certification, and agency notification.

  13. 30 CFR 715.13 - Postmining use of land.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... services. Schools, hospitals, churches, libraries, water-treatment facilities, solid-waste disposal... land area of housing capacity, associated open space, and minor vehicle parking and recreation...

  14. 30 CFR 715.13 - Postmining use of land.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... services. Schools, hospitals, churches, libraries, water-treatment facilities, solid-waste disposal... land area of housing capacity, associated open space, and minor vehicle parking and recreation...

  15. 40 CFR 35.2030 - Facilities planning.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... STATE AND LOCAL ASSISTANCE Grants for Construction of Treatment Works § 35.2030 Facilities planning. (a... ponds, trickling filters, oxidation ditches, or overland-flow land treatment; and for unsewered portions... a schedule the State accepts and such schedule is inserted as a special condition of the grant...

  16. Summary report of trip to European all weather landing facilities October 18-29, 1971.

    DOT National Transportation Integrated Search

    1971-10-18

    This report represents a summary of the information gathered during the joint FAA/MITRE/TSC visit to European Category II and Category III landing facilities over the period 18 October 1971 to 29 October 1971. Part I presents overviews of the attitud...

  17. STS-114: Discovery Crew Arrival for Launch at Shuttle Landing Facility

    NASA Technical Reports Server (NTRS)

    2005-01-01

    Live Footage of Discovery's STS-114 Crew Arriving at the Shuttle Landing Facility at Kennedy Space Center is shown. George Diller is the narrator for this event. Commander, Eileen Collins, is seen introducing the STS-114 crew who consists of: Pilot, James Kelley, Mission Specialist, Charles Camarda, Mission Specialist, Wendy Lawrence, Mission Specialist, Soichi Noguchi, Mission Specialist, Steve Robinson, and Mission Specialist Andy Thomas. Each crewmember addresses the news media about their role on this mission.

  18. Image Analysis for Facility Siting: a Comparison of Lowand High-altitude Image Interpretability for Land Use/land Cover Mapping

    NASA Technical Reports Server (NTRS)

    Borella, H. M.; Estes, J. E.; Ezra, C. E.; Scepan, J.; Tinney, L. R.

    1982-01-01

    For two test sites in Pennsylvania the interpretability of commercially acquired low-altitude and existing high-altitude aerial photography are documented in terms of time, costs, and accuracy for Anderson Level II land use/land cover mapping. Information extracted from the imagery is to be used in the evaluation process for siting energy facilities. Land use/land cover maps were drawn at 1:24,000 scale using commercially flown color infrared photography obtained from the United States Geological Surveys' EROS Data Center. Detailed accuracy assessment of the maps generated by manual image analysis was accomplished employing a stratified unaligned adequate class representation. Both 'area-weighted' and 'by-class' accuracies were documented and field-verified. A discrepancy map was also drawn to illustrate differences in classifications between the two map scales. Results show that the 1:24,000 scale map set was more accurate (99% to 94% area-weighted) than the 1:62,500 scale set, especially when sampled by class (96% to 66%). The 1:24,000 scale maps were also more time-consuming and costly to produce, due mainly to higher image acquisition costs.

  19. Shuttle Discovery Landing at Palmdale, California, Maintenance Facility

    NASA Technical Reports Server (NTRS)

    1995-01-01

    NASA Dryden Flight Research Center pilot Tom McMurtry lands NASA's Shuttle Carrier Aircraft with Space Shuttle Discovery attached at Rockwell Aerospace's Palmdale, California, facility about 1:00 p.m. Pacific Daylight Time (PDT). There for nine months of scheduled maintenance, Discovery and the 747 were completing a two-day flight from Kennedy Space Center, Florida, that began at 7:04 a.m. Eastern Standard Time on 27 September and included an overnight stop at Salt Lake City International Airport, Utah. At the conclusion of this mission, Discovery had flown 21 shuttle missions, totaling more than 142 days in orbit. Space Shuttles are the main element of America's Space Transportation System and are used for space research and other space applications. The shuttles are the first vehicles capable of being launched into space and returning to Earth on a routine basis. Space Shuttles are used as orbiting laboratories in which scientists and mission specialists conduct a wide variety of scientific experiments. Crews aboard shuttles place satellites in orbit, rendezvous with satellites to carry out repair missions and return them to space, and retrieve satellites and return them to Earth for refurbishment and reuse. Space Shuttles are true aerospace vehicles. They leave Earth and its atmosphere under rocket power provided by three liquid-propellant main engines with two solid-propellant boosters attached plus an external liquid-fuel tank. After their orbital missions, they streak back through the atmosphere and land like airplanes. The returning shuttles, however, land like gliders, without power and on runways. Other rockets can place heavy payloads into orbit, but, they can only be used once. Space Shuttles are designed to be continually reused. When Space Shuttles are used to transport complete scientific laboratories into space, the laboratories remain inside the payload bay throughout the mission. They are then removed after the Space Shuttle returns to Earth and

  20. Shuttle landing facility cloud cover study: Climatological analysis and two tenths cloud cover rule evaluation

    NASA Technical Reports Server (NTRS)

    Atchison, Michael K.; Schumann, Robin; Taylor, Greg; Warburton, John; Wheeler, Mark; Yersavich, Ann

    1993-01-01

    The two-tenths cloud cover rule in effect for all End Of Mission (EOM) STS landings at the Kennedy Space Center (KSC) states: 'for scattered cloud layers below 10,000 feet, cloud cover must be observed to be less than or equal to 0.2 at the de-orbit burn go/no-go decision time (approximately 90 minutes before landing time)'. This rule was designed to protect against a ceiling (below 10,000 feet) developing unexpectedly within the next 90 minutes (i.e., after the de-orbit burn decision and before landing). The Applied Meteorological Unit (AMU) developed and analyzed a database of cloud cover amounts and weather conditions at the Shuttle Landing Facility for a five-year (1986-1990) period. The data indicate the best time to land the shuttle at KSC is during the summer while the worst time is during the winter. The analysis also shows the highest frequency of landing opportunities occurs for the 0100-0600 UTC and 1300-1600 UTC time periods. The worst time of the day to land a shuttle is near sunrise and during the afternoon. An evaluation of the two-tenths cloud cover rule for most data categorizations has shown that there is a significant difference in the proportions of weather violations one and two hours subsequent to initial conditions of 0.2 and 0.3 cloud cover. However, for May, Oct., 700 mb northerly wind category, 1500 UTC category, and 1600 UTC category there is some evidence that the 0.2 cloud cover rule may be overly conservative. This possibility requires further investigation. As a result of these analyses, the AMU developed nomograms to help the Spaceflight Meteorological Group (SMG) and the Cape Canaveral Forecast Facility (CCFF) forecast cloud cover for EOM and Return to Launch Site (RTLS) at KSC. Future work will include updating the two tenths database, further analysis of the data for several categorizations, and developing a proof of concept artificial neural network to provide forecast guidance of weather constraint violations for shuttle

  1. Substance Abuse Treatment in Adult and Juvenile Correctional Facilities: Findings from the Uniform Facility Data Set 1997 Survey of Correctional Facilities.

    ERIC Educational Resources Information Center

    Marsden, Mary Ellen, Ed.; Straw, Richard S., Ed.

    This report presents methodology and findings from the Uniform Facility Data Set (UFDS) 1997 Survey of Correctional Facilities, which surveyed about 7,600 adult and juvenile correctional facilities to identify those that provide on-site substance abuse treatment to their inmates or residents. The survey assesses substance abuse treatment provided…

  2. 40 CFR 264.271 - Treatment program.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ....271 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND DISPOSAL FACILITIES Land... land treatment program that is designed to ensure that hazardous constituents placed in or on the...

  3. 40 CFR 264.271 - Treatment program.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ....271 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND DISPOSAL FACILITIES Land... land treatment program that is designed to ensure that hazardous constituents placed in or on the...

  4. 40 CFR 264.271 - Treatment program.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ....271 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND DISPOSAL FACILITIES Land... land treatment program that is designed to ensure that hazardous constituents placed in or on the...

  5. 40 CFR 264.271 - Treatment program.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ....271 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND DISPOSAL FACILITIES Land... land treatment program that is designed to ensure that hazardous constituents placed in or on the...

  6. 40 CFR 264.271 - Treatment program.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ....271 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND DISPOSAL FACILITIES Land... land treatment program that is designed to ensure that hazardous constituents placed in or on the...

  7. Pain treatment facilities: do we need quantity or quality?

    PubMed

    de Meij, Nelleke; Köke, Albère; van der Weijden, Trudy; van Kleef, Maarten; Patijn, Jacob

    2014-10-01

    Chronic pain patients referred to a pain treatment facility have no guarantee that they will receive a proper diagnostic procedure or treatment. To obtain information about organizational aspects of pain treatment facilities and the content of their daily pain practice, we performed a questionnaire survey. The aim of the study was to evaluate the amount of pain treatment facilities, the content of organized specialized pain care and adherence to the criteria of the internationally accepted guidelines for pain treatment services. The University Pain Centre Maastricht in the Department of Anaesthesiology and Pain Management at Maastricht University Medical Centre developed a questionnaire survey based on the Recommendations for Pain Treatment Services of the International Association for the Study of Pain (IASP). The questionnaire was sent to the medical boards of all hospitals in the Netherlands (n=94). The response rate was 86% (n=81). Of all hospitals, 88.9% (n=72) reported the provision of organized specialized pain care, which was provided by a pain management team in 86.1% (n=62) and by an individual specialist in 13.9% (n=10). Insight was obtained from pain treatment facilities in five different domains: the organizational structure of pain management, composition of the pain team, pain team practice, patient characteristics, and research and education facilities. Although 88.9% of all hospitals stated that organized specialized pain care was provided, only a few hospitals could adhere to the criteria for pain treatment services of the IASP. The outcome of the questionnaire survey may help to define quality improvement standards for pain treatment facilities. © 2014 John Wiley & Sons, Ltd.

  8. Nuclear power-related facilities and neighboring land price: a case study on the Mutsu-Ogawara region, Japan.

    PubMed

    Yamane, Fumihiro; Ohgaki, Hideaki; Asano, Kota

    2011-12-01

    From the perspective of risk, nuclear-power-related facilities (NPRFs) are often regarded as locally undesirable land use. However, construction of NPRFs contributes to social infrastructural improvement and job creation in the host communities. This raises a question: How large are these positive and negative effects? To approach this question from an economic viewpoint, we estimated the hedonic land price function for the Mutsu-Ogawara region of Japan from 1976 to 2004 and analyzed year-by-year fluctuations in land prices around the NPRFs located there. Land prices increased gradually in the neighborhood of the nuclear fuel cycle facilities (NFCFs) in Rokkasho Village, except for some falling (i) from 1982 to 1983 (the first official announcement of the project of construction came in 1983), (ii) from 1987 to 1988 (in 1988, the construction began and opposition movements against the project reached their peak), and (iii) from 1998 to 1999 (the pilot carry-in of spent fuels into the reprocessing plant began in 1998). Land prices around the Higashidori Nuclear Power Plant decreased during the period 1981-1982, when the Tohoku Electric Power Corp. and Tokyo Electric Power Corp. announced their joint construction plan. On the other hand, we obtained some results, even though not significant, indicating that land prices around Ohminato and Sekinehama harbors changed with the arrival and departure of the nuclear ship Mutsu, which suffered a radiation leak in 1974. © 2011 Society for Risk Analysis.

  9. Region 9 NPDES Facilities - Waste Water Treatment Plants

    EPA Pesticide Factsheets

    Point geospatial dataset representing locations of NPDES Waste Water Treatment Plant Facilities. NPDES (National Pollution Discharge Elimination System) is an EPA permit program that regulates direct discharges from facilities that discharge treated waste water into waters of the US. Facilities are issued NPDES permits regulating their discharge as required by the Clean Water Act. A facility may have one or more outfalls (dischargers). The location represents the facility or operating plant.

  10. 47 CFR 17.58 - Facilities to be located on land under the jurisdiction of the U.S. Forest Service or the Bureau...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... jurisdiction of the U.S. Forest Service or the Bureau of Land Management. 17.58 Section 17.58 Telecommunication... land under the jurisdiction of the U.S. Forest Service or the Bureau of Land Management. Any... the U.S. Forest Service or the Bureau of Land Management shall include a statement that the facilities...

  11. PROCESS DESIGN MANUAL: LAND TREATMENT OF MUNICIPAL WASTEWATER

    EPA Science Inventory

    The manual presents a rational procedure for the design of land treatment systems. Slow rate, rapid infiltration, and overland flow processes for the treatment of municipal wastewaters are discussed in detail, and the design concepts and criteria are presented. A two-phased plann...

  12. Design considerations for attaining 250-knot test velocities at the aircraft landing dynamics facility

    NASA Technical Reports Server (NTRS)

    Gray, C. E., Jr.; Snyder, R. E.; Taylor, J. T.; Cires, A.; Fitzgerald, A. L.; Armistead, M. F.

    1980-01-01

    Preliminary design studies are presented which consider the important parameters in providing 250 knot test velocities at the Aircraft Landing Dynamics Facility. Four major components of this facility are: the hydraulic jet catapult, the test carriage structure, the reaction turning bucket, and the wheels. Using the hydraulic-jet catapult characteristics, a target design point was selected and a carriage structure was sized to meet the required strength requirements. The preliminary design results indicate that to attain 250 knot test velocities for a given hydraulic jet catapult system, a carriage mass of 25,424 kg (56,000 lbm.) cannot be exceeded.

  13. Risk assessment of CST-7 proposed waste treatment and storage facilities Volume I: Limited-scope probabilistic risk assessment (PRA) of proposed CST-7 waste treatment & storage facilities. Volume II: Preliminary hazards analysis of proposed CST-7 waste storage & treatment facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sasser, K.

    1994-06-01

    In FY 1993, the Los Alamos National Laboratory Waste Management Group [CST-7 (formerly EM-7)] requested the Probabilistic Risk and Hazards Analysis Group [TSA-11 (formerly N-6)] to conduct a study of the hazards associated with several CST-7 facilities. Among these facilities are the Hazardous Waste Treatment Facility (HWTF), the HWTF Drum Storage Building (DSB), and the Mixed Waste Receiving and Storage Facility (MWRSF), which are proposed for construction beginning in 1996. These facilities are needed to upgrade the Laboratory`s storage capability for hazardous and mixed wastes and to provide treatment capabilities for wastes in cases where offsite treatment is not availablemore » or desirable. These facilities will assist Los Alamos in complying with federal and state requlations.« less

  14. 7 CFR 632.15 - Eligible uses and treatment of reclaimed lands.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... are eligible for cost sharing, and (2) Maintain, as applicable, lists of average costs of applying... Qualifications § 632.15 Eligible uses and treatment of reclaimed lands. (a) Reclaimed lands and water may be used... not eligible for cost sharing. (b) Reclaimed land use is determined by the objectives of the land user...

  15. 7 CFR 632.15 - Eligible uses and treatment of reclaimed lands.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... are eligible for cost sharing, and (2) Maintain, as applicable, lists of average costs of applying... Qualifications § 632.15 Eligible uses and treatment of reclaimed lands. (a) Reclaimed lands and water may be used... not eligible for cost sharing. (b) Reclaimed land use is determined by the objectives of the land user...

  16. Data entry module and manuals for the Land Treatment Digital Library

    USGS Publications Warehouse

    Welty, Justin L.; Pilliod, David S.

    2013-01-01

    Across the country, public land managers make decisions each year that influence landscapes and ecosystems within their jurisdictions. Many of these decisions involve vegetation manipulations, which often are referred to as land treatments. These treatments include removal or alteration of plant biomass, seeding of burned areas, application of herbicides, and other activities. Data documenting these land treatments usually are stored at local management offices in various formats. Therefore, anyone interested in the types and effects of land treatments across multiple jurisdictions must first assemble the information, which can be difficult if data discovery and organization involve multiple local offices. A centralized system for storing and accessing the data helps inform land managers when making policy and management considerations and assists scientists in developing sampling designs and studies. The Land Treatment Digital Library (LTDL) was created by the U.S. Geological Survey (USGS) as a comprehensive database incorporating tabular data, documentation, photographs, and spatial data about land treatments in a single system. It was developed over a period of several years and refined based on feedback from partner agencies and stakeholders. Currently, Bureau of Land Management (BLM) land treatment data are being entered by USGS personnel as part of a memorandum of understanding between the USGS and BLM. The LTDL has a website maintained by the USGS Forest and Rangeland Ecosystem Science Center where LTDL data can be viewed http://ltdl.wr.usgs.gov/. The resources and information provided in this data series allow other agencies, organizations, and individuals to download an empty, stand-alone LTDL database to individual or networked computers. Data entered in these databases may be submitted to the USGS for possible inclusion in the online LTDL. Multiple computer programs are used to accomplish the objective of the LTDL. The support of an information

  17. Addressing social aspects associated with wastewater treatment facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Padilla-Rivera, Alejandro; Morgan-Sagastume, Juan Manuel; Noyola, Adalberto

    In wastewater treatment facilities (WWTF), technical and financial aspects have been considered a priority, while other issues, such as social aspects, have not been evaluated seriously and there is not an accepted methodology for assessing it. In this work, a methodology focused on social concerns related to WWTF is presented. The methodology proposes the use of 25 indicators as a framework for measuring social performance to evaluate the progress in moving towards sustainability. The methodology was applied to test its applicability and effectiveness in two WWTF in Mexico (urban and rural). This evaluation helped define the key elements, stakeholders andmore » barriers in the facilities. In this context, the urban facility showed a better overall performance, a result that may be explained mainly by the better socioeconomic context of the urban municipality. Finally, the evaluation of social aspects using the semi-qualitative approach proposed in this work allows for a comparison between different facilities and for the identification of strengths and weakness, and it provides an alternative tool for achieving and improving wastewater management. - Highlights: • The methodology proposes 25 indicators as a framework for measuring social performance in wastewater treatment facilities. • The evaluation helped to define the key elements, stakeholders and barriers in the wastewater treatment facilities. • The evaluation of social aspects allows the identification of strengths and weakness for improving wastewater management. • It provides a social profile of the facility that highlights the best and worst performances.« less

  18. Texture Modification of the Shuttle Landing Facility Runway at Kennedy Space Center

    NASA Technical Reports Server (NTRS)

    Daugherty, Robert H.; Yager, Thomas J.

    1997-01-01

    This paper describes the test procedures and the criteria used in selecting an effective runway-surface-texture modification at the Kennedy Space Center (KSC) Shuttle Landing Facility (SLF) to reduce Orbiter tire wear. The new runway surface may ultimately result in an increase of allowable crosswinds for launch and landing operations. The modification allows launch and landing operations in 20-knot crosswinds, if desired. This 5-knot increase over the previous 15-knot limit drastically increases landing safety and the ability to make on-time launches to support missions in which Space Station rendezvous are planned. The paper presents the results of an initial (1988) texture modification to reduce tire spin-up wear and then describes a series of tests that use an instrumented ground-test vehicle to compare tire friction and wear characteristics, at small scale, of proposed texture modifications placed into the SLF runway surface itself. Based on these tests, three candidate surfaces were chosen to be tested at full-scale by using a highly modified and instrumented transport aircraft capable of duplicating full Orbiter landing profiles. The full-scale Orbiter tire testing revealed that tire wear could be reduced approximately by half with either of two candidates. The texture-modification technique using a Humble Equipment Company Skidabrader(trademark) shotpeening machine proved to be highly effective, and the entire SLF runway surface was modified in September 1994. The extensive testing and evaluation effort that preceded the selection of this particular surface-texture-modification technique is described herein.

  19. Attenuation of municipal landfill leachate through land treatment

    PubMed Central

    2014-01-01

    The treatment of municipal landfill’s leachate is considered as one of the most significant environmental issues. In this study a laboratory experiment was conducted through land treatment, achieving an efficient and economical method by using Vetiver plant. Moreover, the effects of land treatment of leachate of municipal landfills on the natural reduction of organic and inorganic contaminants in the leachate after the pre-treatment in the Aradkouh disposal center are invested. Three pilots including the under-investigation region’s soil planted by Vetiver plant, the region’s intact soil pilot and the artificial composition of the region’s soil including the natural region’s soil, sand, and rock stone are used. The leachate, having passed its initial treatment, passed through the soil and to the pilot. It was collected in the end of the pilots and its organic and inorganic contaminants were measured. However, the land treatment of leachate was conducted in a slow rate at various speeds. According to the results, in order to remove COD, BOD5, TDS, TSS, TOC the best result was obtained in the region’s soil planted with Vetiver plant and at the speed of 0.2 ml per minute which resulted 99.1%, 99.7%, 52.4%, 98.8%, 94.9% removal efficiencies, respectively. It also can be concluded that the higher the organic rate load is, the lower the efficiency of the removal would be. In addition, EC & pH were measured and the best result was obtained in the region’s soil planted with Vetiver plant and at the speed of 0.2 ml/min. PMID:24397862

  20. Final report of the decontamination and decommissioning of the exterior land areas at the Grand Junction Projects Office facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Widdop, M.R.

    1995-09-01

    The US Department of Energy (DOE) Grand Junction Projects Office (GJPO) facility occupies approximately 56.4 acres (22.8 hectares) along the Gunnison River near Grand Junction, Colorado. The site was contaminated with uranium ore and mill tailings during uranium-refining activities conducted by the Manhattan Engineer District and during pilot-milling experiments conducted for the US Atomic Energy Commission`s (AEC`s) domestic uranium procurement program. The GJPO facility was the collection and assay point for AEC uranium and vanadium oxide purchases until the early 1970s. The DOE Decontamination and Decommissioning Program sponsored the Grand Junction Projects Office Remedial Action Project (GJPORAP) to remediate themore » facility lands, site improvements, and the underlying aquifer. The site contractor, Rust Geotech, was the Remedial Action Contractor for GJPORAP. The exterior land areas of the facility assessed as contaminated have been remediated in accordance with identified standards and can be released for unrestricted use. Restoration of the aquifer will be accomplished through the natural flushing action of the aquifer during the next 50 to 80 years. The remediation of the DOE-GJPO facility buildings is ongoing and will be described in a separate report.« less

  1. RETROFITTING CONTROL FACILITIES FOR WET-WEATHER FLOW TREATMENT

    EPA Science Inventory

    Available technologies were evaluated to demonstrate the technical feasibility and cost effectiveness of retrofitting existing facilities to handle wet-weather flow. Cost/benefit relationships were also compared to construction of new conventional control and treatment facilities...

  2. 42 CFR 483.354 - General requirements for psychiatric residential treatment facilities.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... treatment facilities. 483.354 Section 483.354 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES... LONG TERM CARE FACILITIES Condition of Participation for the Use of Restraint or Seclusion in Psychiatric Residential Treatment Facilities Providing Inpatient Psychiatric Services for Individuals Under...

  3. Forecasting land cover change impacts on drinking water treatment costs in Minneapolis, Minnesota

    NASA Astrophysics Data System (ADS)

    Woznicki, S. A.; Wickham, J.

    2017-12-01

    Source protection is a critical aspect of drinking water treatment. The benefits of protecting source water quality in reducing drinking water treatment costs are clear. However, forecasting the impacts of environmental change on source water quality and its potential to influence future treatment processes is lacking. The drinking water treatment plant in Minneapolis, MN has recognized that land cover change threatens water quality in their source watershed, the Upper Mississippi River Basin (UMRB). Over 1,000 km2 of forests, wetlands, and grasslands in the UMRB were lost to agriculture from 2008-2013. This trend, coupled with a projected population increase of one million people in Minnesota by 2030, concerns drinking water treatment plant operators in Minneapolis with respect to meeting future demand for clean water in the UMRB. The objective of this study is to relate land cover change (forest and wetland loss, agricultural expansion, urbanization) to changes in treatment costs for the Minneapolis, MN drinking water utility. To do this, we first developed a framework to determine the relationship between land cover change and water quality in the context of recent historical changes and projected future changes in land cover. Next we coupled a watershed model, the Soil and Water Assessment Tool (SWAT) to projections of land cover change from the FOREcasting SCEnarios of Land-use Change (FORE-SCE) model for the mid-21st century. Using historical Minneapolis drinking water treatment data (chemical usage and costs), source water quality in the UMRB was linked to changes in treatment requirements as a function of projected future land cover change. These analyses will quantify the value of natural landscapes in protecting drinking water quality and future treatment processes requirements. In addition, our study provides the Minneapolis drinking water utility with information critical to their planning and capital improvement process.

  4. Sinking Coastlines: Land Subsidence at Aquaculture Facilities in the Yellow River Delta, China, measured with Differential Synthetic Aperture Radar (D-InSAR)

    NASA Astrophysics Data System (ADS)

    Higgins, S.; Overeem, I.; Tanaka, A.; Syvitski, J. P.

    2013-12-01

    Land subsidence in river deltas is a global problem. It heightens storm surges, salinates groundwater, intensifies river flooding, destabilizes infrastructure and accelerates shoreline retreat. Measurements of delta subsidence typically rely on point measures such as GPS devices, tide gauges or extensometers, but spatial coverage is needed to fully assess risk across river deltas. Differential Interferometric Synthetic Aperture Radar (D-InSAR) is a satellite-based technique that can provide maps of ground deformation with mm to cm-scale vertical resolution. We apply D-InSAR to the coast of the Yellow River Delta in China, which is dominated by aquaculture facilities and has experienced severe coastal erosion in the last twenty years. We extract deformation patterns from dry land adjacent to aquaculture facilities along the coast, allowing the first measurements of subsidence at a non-urban delta shoreline. Results show classic cones-of-depression surrounding aquaculture facilities, likely due to groundwater pumping. Subsidence rates are as high as 250 mm/y at the largest facility on the delta. These rates exceed local and global average sea level rise by nearly two orders of magnitude. If these rates continue, large aquaculture facilities in the area could induce more than a meter of relative sea level rise every five years. Given the global explosion in fish farming in recent years, these results also suggest that similar subsidence and associated relative sea level rise may present a significant hazard for other Asian megadeltas. False-color MODIS image of the Yellow River delta in September 2012. Water appears dark blue, highlighting the abundance of aquaculture facilities along the coast. Green land is primarily agricultural; brown is urban. Red boxes indicate locations of aquaculture facilities examined in this study. Figure from Higgins, S., Overeem, I., Tanaka, A., & Syvitski, J.P.M., (2013), Land Subsidence at Aquaculture Facilities in the Yellow River

  5. Energy Efficiency Strategies for Municipal Wastewater Treatment Facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Daw, J.; Hallett, K.; DeWolfe, J.

    2012-01-01

    Water and wastewater systems are significant energy consumers with an estimated 3%-4% of total U.S. electricity consumption used for the movement and treatment of water and wastewater. Water-energy issues are of growing importance in the context of water shortages, higher energy and material costs, and a changing climate. In this economic environment, it is in the best interest for utilities to find efficiencies, both in water and energy use. Performing energy audits at water and wastewater treatment facilities is one way community energy managers can identify opportunities to save money, energy, and water. In this paper the importance of energymore » use in wastewater facilities is illustrated by a case study of a process energy audit performed for Crested Butte, Colorado's wastewater treatment plant. The energy audit identified opportunities for significant energy savings by looking at power intensive unit processes such as influent pumping, aeration, ultraviolet disinfection, and solids handling. This case study presents best practices that can be readily adopted by facility managers in their pursuit of energy and financial savings in water and wastewater treatment. This paper is intended to improve community energy managers understanding of the role that the water and wastewater sector plays in a community's total energy consumption. The energy efficiency strategies described provide information on energy savings opportunities, which can be used as a basis for discussing energy management goals with water and wastewater treatment facility managers.« less

  6. Region 9 NPDES Facilities 2012- Waste Water Treatment Plants

    EPA Pesticide Factsheets

    Point geospatial dataset representing locations of NPDES Waste Water Treatment Plant Facilities. NPDES (National Pollution Discharge Elimination System) is an EPA permit program that regulates direct discharges from facilities that discharge treated waste water into waters of the US. Facilities are issued NPDES permits regulating their discharge as required by the Clean Water Act. A facility may have one or more outfalls (dischargers). The location represents the facility or operating plant.

  7. 1999 Report on Hanford Site land disposal restriction for mixed waste

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    BLACK, D.G.

    This report was submitted to meet the requirements of Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement) Milestone M-26-011. This milestone requires the preparation of an annual report that covers characterization, treatment, storage, minimization, and other aspects of managing land-disposal-restricted mixed waste at the Hanford Facility.

  8. KENNEDY SPACE CENTER, FLA. - A helicopter approaches an orbiter crew compartment mock-up as part of a “Mode VII” emergency landing simulation at Kennedy Space Center. The purpose is to exercise emergency preparedness personnel, equipment and facilities in rescuing astronauts from a downed orbiter and providing immediate medical attention. This simulation presents an orbiter that has crashed short of the Shuttle Landing Facility in a wooded area 2-1/2 miles south of Runway 33. Emergency crews will respond to the volunteer “astronauts” simulating various injuries. Rescuers must remove the crew, provide triage and transport to hospitals those who need further treatment. Local hospitals are participating in the exercise.

    NASA Image and Video Library

    2004-02-18

    KENNEDY SPACE CENTER, FLA. - A helicopter approaches an orbiter crew compartment mock-up as part of a “Mode VII” emergency landing simulation at Kennedy Space Center. The purpose is to exercise emergency preparedness personnel, equipment and facilities in rescuing astronauts from a downed orbiter and providing immediate medical attention. This simulation presents an orbiter that has crashed short of the Shuttle Landing Facility in a wooded area 2-1/2 miles south of Runway 33. Emergency crews will respond to the volunteer “astronauts” simulating various injuries. Rescuers must remove the crew, provide triage and transport to hospitals those who need further treatment. Local hospitals are participating in the exercise.

  9. LAND TREATMENT OF TWO PLATEAU MATERIALS CONTAMINATED WITH PAHS

    EPA Science Inventory

    This study was designed to evaluate several treatments for their ability to enhance the biological removal of polycyclic aromatic hydrocarbons (PAHs) from contaminated soil and sediment. Previously land-treated material was used to test the treatments in a 13 week bench scale stu...

  10. A Case Study of Land Treatment in a Cold Climate-West Dover, Vermont,

    DTIC Science & Technology

    1982-12-01

    Research & ADA124~i8Engineering Laboratory A case study of land treatment in a cold climate- West Dover, Vermont IT C;0 ~󈨜 03 09 052 CRREL Report 82...44 December 1982 A case study of land treatment in a cold climate- West Dover, Vermont J.R. Bouzoun, D.W. Meals and E.A. Cassell Prepared for OFFICE OF...4. TITLE (end SL : 5. TYPE OF REPORT & PERIOD COVERED A CASE STUDY OF LAND TREATMENT IN A COLD CLIMATE-WEST DOVER, VERMONT 6. PERFORMING ORG. REPORT

  11. STS-26 crew arrives at KSC Shuttle Landing Facility (SLF)

    NASA Technical Reports Server (NTRS)

    1987-01-01

    STS-26 Discovery, Orbiter Vehicle (OV) 103, crew arrives at Kennedy Space Center (KSC) Shuttle Landing Facility (SLF). The recently announced flight crew of the next space shuttle mission STS-26 stands in front of NASA T-38 aircraft. The STS-26 crew is making a motivational visit to KSC in order to talk to and meet the support teams that help launch the shuttle. From left to right are: Mission Specialist (MS) David C. Hilmers who flew on 51J; Pilot Richard O. Covey who flew on 51I; Commander Frederick H. Hauck who flew as commander on 51A and as pilot on STS-7; and MS George D. Nelson who flew on 41C and 61C.

  12. Comparing the Costs of Military Treatment Facilities with Private Sector Care

    DTIC Science & Technology

    2016-02-01

    Log: H 15-000527 Comparing the Costs of Military Treatment Facilities with Private Sector Care Philip M. Lurie INSTITUTE FOR DEFENSE ANALYSES 4850 Mark...other national challenges. Comparing the Costs of Military Treatment Facilities with Private Sector Care Philip M. Lurie I N S T I T U T E F O R D...members. The latter benefit, known as TRICARE, serves 9.5 million beneficiaries worldwide, and consists of care in Military Treatment Facilities (MTFs

  13. Opportunities for Automated Demand Response in California Wastewater Treatment Facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aghajanzadeh, Arian; Wray, Craig; McKane, Aimee

    Previous research over a period of six years has identified wastewater treatment facilities as good candidates for demand response (DR), automated demand response (Auto-­DR), and Energy Efficiency (EE) measures. This report summarizes that work, including the characteristics of wastewater treatment facilities, the nature of the wastewater stream, energy used and demand, as well as details of the wastewater treatment process. It also discusses control systems and automated demand response opportunities. Furthermore, this report summarizes the DR potential of three wastewater treatment facilities. In particular, Lawrence Berkeley National Laboratory (LBNL) has collected data at these facilities from control systems, submetered processmore » equipment, utility electricity demand records, and governmental weather stations. The collected data were then used to generate a summary of wastewater power demand, factors affecting that demand, and demand response capabilities. These case studies show that facilities that have implemented energy efficiency measures and that have centralized control systems are well suited to shed or shift electrical loads in response to financial incentives, utility bill savings, and/or opportunities to enhance reliability of service. In summary, municipal wastewater treatment energy demand in California is large, and energy-­intensive equipment offers significant potential for automated demand response. In particular, large load reductions were achieved by targeting effluent pumps and centrifuges. One of the limiting factors to implementing demand response is the reaction of effluent turbidity to reduced aeration at an earlier stage of the process. Another limiting factor is that cogeneration capabilities of municipal facilities, including existing power purchase agreements and utility receptiveness to purchasing electricity from cogeneration facilities, limit a facility’s potential to participate in other DR activities.« less

  14. Proton facility economics: the importance of "simple" treatments.

    PubMed

    Johnstone, Peter A S; Kerstiens, John; Richard, Helsper

    2012-08-01

    Given the cost and debt incurred to build a modern proton facility, impetus exists to minimize treatment of patients with complex setups because of their slower throughput. The aim of this study was to determine how many "simple" cases are necessary given different patient loads simply to recoup construction costs and debt service, without beginning to cover salaries, utilities, beam costs, and so on. Simple cases are ones that can be performed quickly because of an easy setup for the patient or because the patient is to receive treatment to just one or two fields. A "standard" construction cost and debt for 1, 3, and 4 gantry facilities were calculated from public documents of facilities built in the United States, with 100% of the construction funded through standard 15-year financing at 5% interest. Clinical best case (that each room was completely scheduled with patients over a 14-hour workday) was assumed, and a statistical analysis was modeled with debt, case mix, and payer mix moving independently. Treatment times and reimbursement data from the investigators' facility for varying complexities of patients were extrapolated for varying numbers treated daily. Revenue assumptions of $X per treatment were assumed both for pediatric cases (a mix of Medicaid and private payer) and state Medicare simple case rates. Private payer reimbursement averages $1.75X per treatment. The number of simple patients required daily to cover construction and debt service costs was then derived. A single gantry treating only complex or pediatric patients would need to apply 85% of its treatment slots simply to service debt. However, that same room could cover its debt treating 4 hours of simple patients, thus opening more slots for complex and pediatric patients. A 3-gantry facility treating only complex and pediatric cases would not have enough treatment slots to recoup construction and debt service costs at all. For a 4-gantry center, focusing on complex and pediatric cases alone

  15. NPDES Permit for Riverview Estates Wastewater Treatment Facility in North Dakota

    EPA Pesticide Factsheets

    Under National Pollutant Discharge Elimination System permit number ND-0031143, the Riverview Estates Wastewater Treatment Facility is authorized to discharge from its wastewater treatment facility in designated locations as described in the permit.

  16. First Dutch Consensus of Pain Quality Indicators for Pain Treatment Facilities.

    PubMed

    de Meij, Nelleke; van Grotel, Marloes; Patijn, Jacob; van der Weijden, Trudy; van Kleef, Maarten

    2016-01-01

    There is a general consensus about the need to define and improve the quality of pain treatment facilities. Although guidelines and recommendations to improve the quality of pain practice management have been launched, provision of appropriate pain treatment is inconsistent and the quality of facilities varies widely. The aim of the study was to develop an expert-agreed list of quality indicators applicable to pain treatment facilities. The list was also intended to be used as the basis for a set of criteria for registered status of pain treatment facilities. The University Pain Center Maastricht at the Department of Anesthesiology and Pain Management of the Maastricht University Medical Center conducted a 3-round Delphi study in collaboration with the Board of the Pain Section of the Dutch Society of Anesthesiologists (NVA). Twenty-five quality indicators were selected as relevant to 2 types of pain treatment facilities, pain clinics and pain centers. The final expert-agreed list consisted of 22 quality indicators covering 7 quality domains: supervision, availability of care, staffing level and patient load, quality policy, multidisciplinarity, regionalization, and research and education. This set of quality indicators may facilitate organizational evaluation and improve insight into service quality from the perspectives of patients, pain specialists, and other healthcare professionals. Recommendations for improvements to the current set of quality indicators are made. In 2014 the process of registering pain treatment facilities in the Netherlands started; facilities can register as a pain clinic or pain center. © 2015 World Institute of Pain.

  17. The evaluation of ASOS for the Kennedy Space Center's Shuttle Landing Facility

    NASA Technical Reports Server (NTRS)

    Yersavich, Ann; Wheeler, Mark; Taylor, Gregory; Schumann, Robin; Manobianco, John

    1994-01-01

    This report documents the Applied Meteorology Unit's (AMU) evaluation of the effectiveness and utility of the Automated Surface Observing System (ASOS) in terms of spaceflight operations and user requirements. In particular, the evaluation determines which of the Shuttle Landing Facility (SLF) observation requirements can be satisfied by ASOS. This report also includes a summary of ASOS' background, current configuration and specifications, system performance, and the possible concepts of operations for use of ASOS at the SLF. This evaluation stems from a desire by the Air Force to determine if ASOS units could be used to reduce the cost of SLF meteorological observations.

  18. 77 FR 42621 - Irradiation Treatment; Location of Facilities in the Southern United States

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-20

    .... APHIS-2009-0100] RIN 0579-AD35 Irradiation Treatment; Location of Facilities in the Southern United... amending the phytosanitary treatment regulations to provide generic criteria for new irradiation treatment facilities in the Southern States of the United States. This action will allow irradiation facilities to be...

  19. 33 CFR 143.105 - Personnel landings.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Personnel landings. 143.105...) OUTER CONTINENTAL SHELF ACTIVITIES DESIGN AND EQUIPMENT OCS Facilities § 143.105 Personnel landings. (a) Sufficient personnel landings shall be provided on each manned OCS facility to assure safe access and egress...

  20. 33 CFR 143.105 - Personnel landings.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Personnel landings. 143.105...) OUTER CONTINENTAL SHELF ACTIVITIES DESIGN AND EQUIPMENT OCS Facilities § 143.105 Personnel landings. (a) Sufficient personnel landings shall be provided on each manned OCS facility to assure safe access and egress...

  1. Process Design Manual for Land Treatment of Municipal Wastewater.

    ERIC Educational Resources Information Center

    Crites, R.; And Others

    This manual presents a procedure for the design of land treatment systems. Slow rate, rapid infiltration, and overland flow processes for the treatment of municipal wastewaters are given emphasis. The basic unit operations and unit processes are discussed in detail, and the design concepts and criteria are presented. The manual includes design…

  2. The index of tobacco treatment quality: development of a tool to assess evidence-based treatment in a national sample of drug treatment facilities.

    PubMed

    Cupertino, A Paula; Hunt, Jamie J; Gajewski, Byron J; Jiang, Yu; Marquis, Janet; Friedmann, Peter D; Engelman, Kimberly K; Richter, Kimber P

    2013-03-15

    Quitting smoking improves health and drug use outcomes among people in treatment for substance abuse. The twofold purpose of this study is to describe tobacco treatment provision across a representative sample of U.S. facilities and to use these data to develop the brief Index of Tobacco Treatment Quality (ITTQ). We constructed survey items based on current tobacco treatment guidelines, existing surveys, expert input, and qualitative research. We administered the survey to a stratified sample of 405 facility administrators selected from all 3,800 U.S. adult outpatient facilities listed in the SAMHSA Inventory of Substance Abuse Treatment Services. We constructed the ITTQ with a subset of 7 items that have the strongest clinical evidence for smoking cessation. Most facilities (87.7%) reported that a majority of their clients were asked if they smoke cigarettes. Nearly half of facilities (48.6%) reported that a majority of their smoking clients were advised to quit. Fewer (23.3%) reported that a majority of their smoking clients received tobacco treatment counseling and even fewer facilities (18.3%) reported a majority of their smoking clients were advised to use quit smoking medications. The median facility ITTQ score was 2.57 (on a scale of 1-5) and the ITTQ displayed good internal consistency (Cronbach's alpha = .844). Moreover, the ITTQ had substantial test-retest reliability (.856), and ordinal confirmatory factor analysis found that our one-factor model for ITTQ fit the data very well with a CFI of 0.997 and an RMSEA of 0.042. The ITTQ is a brief and reliable tool for measuring tobacco treatment quality in substance abuse treatment facilities. Given the clear-cut room for improvement in tobacco treatment, the ITTQ could be an important tool for quality improvement by identifying service levels, facilitating goal setting, and measuring change.

  3. The index of tobacco treatment quality: development of a tool to assess evidence-based treatment in a national sample of drug treatment facilities

    PubMed Central

    2013-01-01

    Background Quitting smoking improves health and drug use outcomes among people in treatment for substance abuse. The twofold purpose of this study is to describe tobacco treatment provision across a representative sample of U.S. facilities and to use these data to develop the brief Index of Tobacco Treatment Quality (ITTQ). Methods We constructed survey items based on current tobacco treatment guidelines, existing surveys, expert input, and qualitative research. We administered the survey to a stratified sample of 405 facility administrators selected from all 3,800 U.S. adult outpatient facilities listed in the SAMHSA Inventory of Substance Abuse Treatment Services. We constructed the ITTQ with a subset of 7 items that have the strongest clinical evidence for smoking cessation. Results Most facilities (87.7%) reported that a majority of their clients were asked if they smoke cigarettes. Nearly half of facilities (48.6%) reported that a majority of their smoking clients were advised to quit. Fewer (23.3%) reported that a majority of their smoking clients received tobacco treatment counseling and even fewer facilities (18.3%) reported a majority of their smoking clients were advised to use quit smoking medications. The median facility ITTQ score was 2.57 (on a scale of 1–5) and the ITTQ displayed good internal consistency (Cronbach’s alpha = .844). Moreover, the ITTQ had substantial test-retest reliability (.856), and ordinal confirmatory factor analysis found that our one-factor model for ITTQ fit the data very well with a CFI of 0.997 and an RMSEA of 0.042. Conclusions The ITTQ is a brief and reliable tool for measuring tobacco treatment quality in substance abuse treatment facilities. Given the clear-cut room for improvement in tobacco treatment, the ITTQ could be an important tool for quality improvement by identifying service levels, facilitating goal setting, and measuring change. PMID:23497366

  4. Statistical Short-Range Forecast Guidance for Cloud Ceilings Over the Shuttle Landing Facility

    NASA Technical Reports Server (NTRS)

    Lambert, Winifred C.

    2001-01-01

    This report describes the results of the AMU's Short-Range Statistical Forecasting task. The cloud ceiling forecast over the Shuttle Landing Facility (SLF) is a critical element in determining whether a Shuttle should land. Spaceflight Meteorology Group (SMG) forecasters find that ceilings at the SLF are challenging to forecast. The AMU was tasked to develop ceiling forecast equations to minimize the challenge. Studies in the literature that showed success in improving short-term forecasts of ceiling provided the basis for the AMU task. A 20-year record of cool-season hourly surface observations from stations in east-central Florida was used for the equation development. Two methods were used: an observations-based (OBS) method that incorporated data from all stations, and a persistence climatology (PCL) method used as the benchmark. Equations were developed for 1-, 2-, and 3-hour lead times at each hour of the day. A comparison between the two methods indicated that the OBS equations performed well and produced an improvement over the PCL equations. Therefore, the conclusion of the AMU study is that OBS equations produced more accurate forecasts than the PCL equations, and can be used in operations. They provide another tool with which to make the ceiling forecasts that are critical to safe Shuttle landings at KSC.

  5. 40 CFR 264.272 - Treatment demonstration.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Section 264.272 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND DISPOSAL FACILITIES Land Treatment § 264.272 Treatment demonstration. (a) For each waste that will be applied to the...

  6. 40 CFR 264.272 - Treatment demonstration.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Section 264.272 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND DISPOSAL FACILITIES Land Treatment § 264.272 Treatment demonstration. (a) For each waste that will be applied to the...

  7. 40 CFR 264.272 - Treatment demonstration.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Section 264.272 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND DISPOSAL FACILITIES Land Treatment § 264.272 Treatment demonstration. (a) For each waste that will be applied to the...

  8. 40 CFR 264.272 - Treatment demonstration.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Section 264.272 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND DISPOSAL FACILITIES Land Treatment § 264.272 Treatment demonstration. (a) For each waste that will be applied to the...

  9. 40 CFR 264.272 - Treatment demonstration.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Section 264.272 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND DISPOSAL FACILITIES Land Treatment § 264.272 Treatment demonstration. (a) For each waste that will be applied to the...

  10. Perceptions of Organizational Functioning in Substance Abuse Treatment Facilities in South Africa

    ERIC Educational Resources Information Center

    Bowles, Steven; Louw, Johann; Myers, Bronwyn

    2011-01-01

    Directors' and treatment staff's perceptions of organizational functioning within substance abuse treatment facilities in four provinces in South Africa were examined via the Texas Christian University's Organizational Readiness for Change instrument. Forty-four treatment facilities (out of 89) participated in the study. Results indicated that…

  11. 3718-F Alkali Metal Treatment and Storage Facility Closure Plan. Revision 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    The Hanford Site, located northwest of the city of Richland, Washington, houses reactors, chemical-separation systems, and related facilities used for the production of special nuclear materials, as well as for activities associated with nuclear energy development. The 300 Area of the Hanford Site contains reactor fuel manufacturing facilities and several research and development laboratories. The 3718-F Alkali Metal Treatment and Storage Facility (3718-F Facility), located in the 300 Area, was used to store and treat alkali metal wastes. Therefore, it is subject to the regulatory requirements for the storage and treatment of dangerous wastes. Closure will be conducted pursuant tomore » the requirements of the Washington Administrative Code (WAC) 173-303-610 (Ecology 1989) and 40 CFR 270.1. Closure also will satisfy the thermal treatment facility closure requirements of 40 CFR 265.381. This closure plan presents a description of the 3718-F Facility, the history of wastes managed, and the approach that will be followed to close the facility. Only hazardous constituents derived from 3718-F Facility operations will be addressed.« less

  12. STS-39 crewmembers arrive at KSC's Shuttle Landing Facility (SLF) in T-38As

    NASA Image and Video Library

    1991-05-06

    STS039-S-003 (20 April 1991) --- Astronaut Michael L. Coats (right) addresses the news media after arriving at the Shuttle Landing Facility along with his six fellow crewmembers. From left are astronauts Richard J. Hieb, L. Blaine Hammond, Guion S. Bluford, Charles L. (Lacy) Veach, Gregory J. Harbaugh and Donald R. McMonagle. The Space Shuttle mate/demate stand is seen in the background. Note: The STS-39 launch of Discovery occurred at 7:33:14 a.m. (EDT), April 28, 1991.

  13. Problem Severity Profiles of Substance Abusing Women in Therapeutic Treatment Facilities

    ERIC Educational Resources Information Center

    Isralowitz, Richard; Reznik, Alexander

    2009-01-01

    This article aims to examine specific substance use profiles among former Soviet Union (FSU) immigrant and native-born women in Israeli therapeutic treatment facilities. Individuals were sampled at drug treatment facilities and assessed using the Addiction Severity Index. ASI scores suggest differences between the two groups. Among the findings…

  14. Provision of Mental Health Services in South African Substance Abuse Treatment Facilities

    ERIC Educational Resources Information Center

    Myers, Bronwyn; Fakier, Nuraan

    2009-01-01

    To date, South African research has not examined mental health service provision in substance abuse treatment facilities, even though these services improve client retention and treatment outcomes. To describe the extent to which substance abuse treatment facilities in Gauteng and KwaZulu-Natal provinces provide clients with mental health services…

  15. Waste Management Facilities Cost Information report for Greater-Than-Class C and DOE equivalent special case waste

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Feizollahi, F.; Shropshire, D.

    This Waste Management Facility Cost Information (WMFCI) report for Greater-Than-Class C low-level waste (GTCC LLW) and DOE equivalent special case waste contains preconceptual designs and planning level life-cycle cost (PLCC) estimates for treatment, storage, and disposal facilities needed for management of GTCC LLW and DOE equivalent waste. The report contains information on 16 facilities (referred to as cost modules). These facilities are treatment facility front-end and back-end support functions (administration support, and receiving, preparation, and shipping cost modules); seven treatment concepts (incineration, metal melting, shredding/compaction, solidification, vitrification, metal sizing and decontamination, and wet/air oxidation cost modules); two storage concepts (enclosedmore » vault and silo); disposal facility front-end functions (disposal receiving and inspection cost module); and four disposal concepts (shallow-land, engineered shallow-land, intermediate depth, and deep geological cost modules). Data in this report allow the user to develop PLCC estimates for various waste management options. A procedure to guide the U.S. Department of Energy (DOE) and its contractor personnel in the use of estimating data is also included in this report.« less

  16. RECYCLING OF WATER TREATMENT PLANT SLUDGE VIA LAND APPLICATION: ASSESSMENT OF RISK

    EPA Science Inventory

    Water treatment sludges (WTS) offer potential benefits when applied to soil and recycling of the waste stream via land application has been proposed as a management option. Recycling of WTS to the land helps conserve landfill disposal capacity and natural resources, but potential...

  17. KENNEDY SPACE CENTER, FLA. - Emergency crew members transport an “injured” astronaut during a “Mode VII” emergency landing simulation at Kennedy Space Center. The purpose of the Mode VII is to exercise emergency preparedness personnel, equipment and facilities in rescuing astronauts from a downed orbiter and providing immediate medical attention. This simulation presents an orbiter that has crashed short of the Shuttle Landing Facility in a wooded area 2-1/2 miles south of Runway 33. Emergency crews are responding to the volunteer astronauts who are simulating various injuries. Rescuers must remove the crew, provide triage and transport to hospitals those who need further treatment. Local hospitals are participating in the exercise.

    NASA Image and Video Library

    2004-02-18

    KENNEDY SPACE CENTER, FLA. - Emergency crew members transport an “injured” astronaut during a “Mode VII” emergency landing simulation at Kennedy Space Center. The purpose of the Mode VII is to exercise emergency preparedness personnel, equipment and facilities in rescuing astronauts from a downed orbiter and providing immediate medical attention. This simulation presents an orbiter that has crashed short of the Shuttle Landing Facility in a wooded area 2-1/2 miles south of Runway 33. Emergency crews are responding to the volunteer astronauts who are simulating various injuries. Rescuers must remove the crew, provide triage and transport to hospitals those who need further treatment. Local hospitals are participating in the exercise.

  18. PROCESS DESIGN MANUAL FOR LAND TREATMENT OF MUNICIPAL WASTEWATER

    EPA Science Inventory

    The USEPA guidance on land treatment of municipal and industrial wastewater is updated for the first time since 1984. The significant new technilogical changes include phytoremediation, vadose zone monitoring, new design approaches to surface irrigation, center pivot irrigation,...

  19. 76 FR 60390 - Irradiation Treatment; Location of Facilities in the Southern United States

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-29

    ... [Docket No. APHIS-2009-0100] RIN 0579-AD35 Irradiation Treatment; Location of Facilities in the Southern... irradiation treatment facilities in the Southern States of the United States. This action would allow irradiation facilities to be located anywhere in these States, subject to approval, rather than only in the...

  20. Central Facilities Area Sewage Lagoon Evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cole, Mark R.

    2013-12-01

    The Central Facilities Area (CFA), located in Butte County, Idaho, at the Idaho National Laboratory has an existing wastewater system to collect and treat sanitary wastewater and non-contact cooling water from the facility. The existing treatment facility consists of three cells: Cell #1 has a surface area of 1.7 acres, Cell #2 has a surface area of 10.3 acres, and Cell #3 has a surface area of 0.5 acres. If flows exceed the evaporative capacity of the cells, wastewater is discharged to a 73.5-acre land application site that uses a center-pivot irrigation sprinkler system. As flows at CFA have decreasedmore » in recent years, the amount of wastewater discharged to the land application site has decreased from 13.64 million gallons in 2004 to no discharge in 2012 and 2013. In addition to the decreasing need for land application, approximately 7.7 MG of supplemental water was added to the system in 2013 to maintain a water level and prevent the clay soil liners in the cells from drying out and “cracking.” The Idaho National Laboratory is concerned that the sewage lagoons and land application site may be oversized for current and future flows. A further concern is the sustainability of the large volumes of supplemental water that are added to the system according to current operational practices. Therefore, this study was initiated to evaluate the system capacity, operational practices, and potential improvement alternatives, as warranted.« less

  1. Availability of Youth Services in U.S. Mental Health Treatment Facilities

    PubMed Central

    Cummings, Janet R.; Case, Brady G.; Ji, Xu; Marcus, Steven C.

    2015-01-01

    Despite concern about access to mental health (MH) services for youth, little is known about the specialty treatment infrastructure serving this population. We used national data to examine which types of MH treatment facilities (hospital- and community-based) were most likely to offer youth services and which types of communities were most likely to have this infrastructure. Larger (p<0.001) and privately owned (p<0.001) facilities were more likely to offer youth services. Rural counties, counties in which a majority of residents were nonwhite, and/or counties with a higher percentage of uninsured residents were less likely to have a community-based MH treatment facility that served youth (p<0.001). PMID:26467795

  2. Availability of Youth Services in U.S. Mental Health Treatment Facilities.

    PubMed

    Cummings, Janet R; Case, Brady G; Ji, Xu; Marcus, Steven C

    2016-09-01

    Despite concern about access to mental health (MH) services for youth, little is known about the specialty treatment infrastructure serving this population. We used national data to examine which types of MH treatment facilities (hospital- and community-based) were most likely to offer youth services and which types of communities were most likely to have this infrastructure. Larger (p < 0.001) and privately owned (p < 0.001) facilities were more likely to offer youth services. Rural counties, counties in which a majority of residents were nonwhite, and/or counties with a higher percentage of uninsured residents were less likely to have a community-based MH treatment facility that served youth (p < 0.001).

  3. INDEPENDENT CONFIRMATORY SURVEY REPORT FOR THE REACTOR BUILDING, HOT LABORATORY, PRIMARY PUMP HOUSE, AND LAND AREAS AT THE PLUM BROOK REACTOR FACILITY, SANDUSKY, OHIO

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Erika N. Bailey

    2011-10-10

    In 1941, the War Department acquired approximately 9,000 acres of land near Sandusky, Ohio and constructed a munitions plant. The Plum Brook Ordnance Works Plant produced munitions, such as TNT, until the end of World War II. Following the war, the land remained idle until the National Advisory Committee for Aeronautics later called the National Aeronautics and Space Administration (NASA) obtained 500 acres to construct a nuclear research reactor designed to study the effects of radiation on materials used in space flight. The research reactor was put into operation in 1961 and was the first of fifteen test facilities eventuallymore » built by NASA at the Plum Brook Station. By 1963, NASA had acquired the remaining land at Plum Brook for these additional test facilities« less

  4. Long-term trends in restoration and associated land treatments in the southwestern United States

    USGS Publications Warehouse

    Copeland, Stella M.; Munson, Seth M.; Pilliod, David S.; Welty, Justin L.; Bradford, John B.; Butterfield, Bradley J.

    2018-01-01

    Restoration treatments, such as revegetation with seeding or invasive species removal, have been applied on U.S. public lands for decades. Temporal trends in these management actions have not been extensively summarized previously, particularly in the southwestern United States where invasive plant species, drought, and fire have altered dryland ecosystems. We assessed long-term (1940–2010) trends in restoration using approximately 4,000 vegetation treatments conducted on Bureau of Land Management lands across the southwestern United States. We found that since 1940, the proportions of seeding and vegetation/soil manipulation (e.g. vegetation removal or plowing) treatments have declined, while the proportions of prescribed burn and invasive species treatments have increased. Treatments in pinyon-juniper and big sagebrush communities declined in comparison to treatments in desert scrub, creosote bush, and riparian woodland communities. Restoration-focused treatment objectives increased relative to resource extraction objectives. Species richness and proportion of native species used in seeding treatments also increased. Inflation-adjusted costs per area rose 750% for vegetation/soil manipulation, 600% for seeding, and 400% for prescribed burn treatments in the decades from 1981 to 2010. Seeding treatments were implemented in warmer and drier years when compared to the climate conditions of the entire study period and warmer and wetter years relative to several years before and after the treatment. These results suggest that treatments over a 70-year period on public lands in the southwestern United States are shifting toward restoration practices that are increasingly large, expensive, and related to fire and invasive species control.

  5. The NASA landing gear test airplane

    NASA Technical Reports Server (NTRS)

    Carter, John F.; Nagy, Christopher J.

    1995-01-01

    A tire and landing gear test facility has been developed and incorporated into a Convair 990 aircraft. The system can simulate tire vertical load profiles to 250,000 lb, sideslip angles to 15 degrees, and wheel braking on actual runways. Onboard computers control the preprogrammed test profiles through a feedback loop and also record three axis loads, tire slip angle, and tire condition. The aircraft to date has provided tire force and wear data for the Shuttle Orbiter tire on three different runways and at east and west coast landing sites. This report discusses the role of this facility in complementing existing ground tire and landing gear test facilities, and how this facility can simultaneously simulate the vertical load, tire slip, velocity, and surface for an entire aircraft landing. A description is given of the aircraft as well as the test system. An example of a typical test sequence is presented. Data collection and reduction from this facility are discussed, as well as accuracies of calculated parameters. Validation of the facility through ground and flight tests is presented. Tests to date have shown that this facility can operate at remote sites and gather complete data sets of load, slip, and velocity on actual runway surfaces. The ground and flight tests have led to a successful validation of this test facility.

  6. 40 CFR 35.917-1 - Content of facilities plan.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... ASSISTANCE STATE AND LOCAL ASSISTANCE Grants for Construction of Treatment Works-Clean Water Act § 35.917-1... application of BPWTT would not meet water quality standards, the facilities plan shall provide for attaining... employing the reuse of waste water and recycling of pollutants; (iii) Land application techniques; (iv...

  7. 40 CFR 35.917-1 - Content of facilities plan.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... ASSISTANCE STATE AND LOCAL ASSISTANCE Grants for Construction of Treatment Works-Clean Water Act § 35.917-1... application of BPWTT would not meet water quality standards, the facilities plan shall provide for attaining... employing the reuse of waste water and recycling of pollutants; (iii) Land application techniques; (iv...

  8. 76 FR 34200 - Land Disposal Restrictions: Revision of the Treatment Standards for Carbamate Wastes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-13

    ... 2050-AG65 Land Disposal Restrictions: Revision of the Treatment Standards for Carbamate Wastes AGENCY... concentration limits before the wastes can be land disposed. The lack of readily available analytical standards.... List of Subjects 40 CFR Part 268 Environmental protection, Hazardous waste, Land disposal restrictions...

  9. Operational Derivation of Surface Albedo and Down-Welling Short-Wave Radiation in the Satellite Application Facility for Land Surface Analysis

    NASA Astrophysics Data System (ADS)

    Geiger, B.; Carrer, D.; Meurey, C.; Roujean, J.-L.

    2006-08-01

    The Satellite Application Facility for Land Surface Anal- ysis hosted by the Portuguese Meteorological Institute in Lisbon generates and distributes value added satellite products for numerical weather prediction and environ- mental applications in near-real time. Within the project consortium M´et´eo-France is responsible for the land sur- face albedo and down-welling short-wave radiation flux products. Since the beginning of the year 2005 Meteosat Second Generation data are routinely processed by the Land-SAF operational system. In general the validation studies carried out so far show a good consistency with in-situ observations or equivalent products derived from other satellites. After one year of operations a summary of the product characteristics and performances is given. Key words: Surface Albedo; Down-welling Radiation; Land-SAF.

  10. PERFORMANCE EVALUATION AT A LONG-TERM FOOD PROCESSING LAND TREATMENT SITE

    EPA Science Inventory

    The objective of this project was to determine the performance of a full scale, operating overland flow land (GEL) treatment system treating nonhazardous waste. Performance was evaluated in terms of treatment of the applied waste and the environmental impact of the system, partic...

  11. Financial Assurance Requirements for Hazardous Waste Treatment, Storage and Disposal Facilities

    EPA Pesticide Factsheets

    The Resource Conservation and Recovery Act (RCRA) requires all treatment, storage and disposal facilities (TSDFs) to demonstrate that they will have the financial resources to properly close the facility

  12. 76 FR 57642 - TRICARE: Unfortunate Sequelae From Noncovered Services in a Military Treatment Facility

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-16

    ... TRICARE: Unfortunate Sequelae From Noncovered Services in a Military Treatment Facility AGENCY: Office of... treatment of complications (unfortunate sequelae) resulting from a noncovered incident of treatment provided in a Military Treatment Facility (MTF), when the initial noncovered service has been authorized by...

  13. 40 CFR 403.19 - Provisions of specific applicability to the Owatonna Waste Water Treatment Facility.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... the Owatonna Waste Water Treatment Facility. 403.19 Section 403.19 Protection of Environment... Owatonna Waste Water Treatment Facility. (a) For the purposes of this section, the term “Participating... Industrial User discharging to the Owatonna Waste Water Treatment Facility in Owatonna, Minnesota, when a...

  14. Westinghouse Cementation Facility of Solid Waste Treatment System - 13503

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jacobs, Torsten; Aign, Joerg

    2013-07-01

    During NPP operation, several waste streams are generated, caused by different technical and physical processes. Besides others, liquid waste represents one of the major types of waste. Depending on national regulation for storage and disposal of radioactive waste, solidification can be one specific requirement. To accommodate the global request for waste treatment systems Westinghouse developed several specific treatment processes for the different types of waste. In the period of 2006 to 2008 Westinghouse awarded several contracts for the design and delivery of waste treatment systems related to the latest CPR-1000 nuclear power plants. One of these contracts contains the deliverymore » of four Cementation Facilities for waste treatment, s.c. 'Follow on Cementations' dedicated to three locations, HongYanHe, NingDe and YangJiang, of new CPR-1000 nuclear power stations in the People's Republic of China. Previously, Westinghouse delivered a similar cementation facility to the CPR-1000 plant LingAo II, in Daya Bay, PR China. This plant already passed the hot functioning tests successfully in June 2012 and is now ready and released for regular operation. The 'Follow on plants' are designed to package three 'typical' kind of radioactive waste: evaporator concentrates, spent resins and filter cartridges. The purpose of this paper is to provide an overview on the Westinghouse experience to design and execution of cementation facilities. (authors)« less

  15. RETROFITTING CONTROL FACILITIES FOR WET WEATHER FLOW TREATMENT

    EPA Science Inventory

    Available technologies were evaluated to demonstrate the technical feasibility and cost-effectiveness of retrofitting existing facilities to handle wet-weather flow. Cost/benefit relationships were also compared to construction of new conventional control and treatment facilitie...

  16. Operational Concept for the Smart Landing Facility (SLF)

    NASA Technical Reports Server (NTRS)

    Thompson, S. D.; Bussolari, S. R.

    2001-01-01

    The purpose of this document is to describe an operational concept for the Smart Landing Facility (SLF). The SLF is proposed as a component of the Small Aircraft Transportation System (SATS) and is envisioned to utilize Communication, Navigation, Surveillance and Air Traffic Management (CNS/ATM) technologies to support higher-volume air traffic operations in a wider variety of weather conditions than are currently possible at airports without an Air Traffic Control Tower (ATCT) or Terminal Radar Approach Control (TRACON). In order to accomplish this, the SLF will provide aircraft sequencing and separation within its terminal airspace (the SLF traffic area) and on the airport surface. The approach taken in this report is to first define and describe the SLF environment and the type of operations and aircraft that must be supported. Services currently provided by an ATCT and TRACON are reviewed and assembled into a set of high-level operational functions. A description of the applicable CNS/ATM technologies that have been deployed in the NAS (National Airspace System) or have been demonstrated to be operationally feasible is presented. A candidate SLF system concept that employs the CNS/ATM technologies is described. This is followed by SLF operational scenarios for minimally-equipped aircraft and for aircraft fully-equipped to make full use of SLF services. An assessment is made of the SLF technology and key research issues are identified.

  17. 77 FR 69769 - Solid Waste Rail Transfer Facilities

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-21

    .... SUMMARY: These final rules govern land-use-exemption permits for solid waste rail transfer facilities. The... ``land-use-exemption permits'' in certain circumstances. Under the CRA, a solid waste rail transfer... grants a land-use-exemption permit for a solid waste rail transfer facility, such permit would only...

  18. Process Control Manual for Aerobic Biological Wastewater Treatment Facilities.

    ERIC Educational Resources Information Center

    Environmental Protection Agency, Washington, DC. Office of Water Programs.

    This Environmental Protection Agency (EPA) publication is an operations manual for activated sludge and trickling filter wastewater treatment facilities. The stated purpose of the manual is to provide an on-the-job reference for operators of these two types of treatment plants. The overall objective of the manual is to aid the operator in…

  19. The land-use of Bandung, its density, overcrowded area and public facility toward a compact city

    NASA Astrophysics Data System (ADS)

    Paramita, B.

    2016-04-01

    The concept of a compact city has been introduced since 1973. It is a utopian vision largely driven by a desire to see more efficient uses of resources. In 1980s, the reconfiguration of the physical urban form of metropolitan areas was increasingly debated by both theorists and practitioners. Recently, the concept of a compact city has been more focused on developed countries in which the population tends to decrease. However, in Asia, except Japan which contains many dense cities, it has become a concept which promotes relatively high residential density with mixed land uses, though rather only in population and density. This paper addresses the land-use of Bandung that having the density over 14,000 people/km2, which has been so much potential toward a compact city. Somehow, unprepared ness of urban planning and regulation, the city seemed overwrought to serve its inhabitants. This condition is shown from the demographic condition, especially population density in Bandung based on its sub areas of the city (SWK). The stack of public facilities in a certain district has led the concentration of density and activity, which finally raising the slum and overcrowded settlement. Finally, this paper explores the implications of land use management and describes challenges faced and possible approaches, especially in land-use management strategies to be implemented in Bandung.

  20. 24 CFR 960.205 - Drug use by applicants: Obtaining information from drug treatment facility.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    .... This section addresses a PHA's authority to request and obtain information from drug abuse treatment... household member. (2) Drug abuse treatment facility. An entity: (i) That holds itself out as providing, and... consent forms signed by such household member that: (i) Requests any drug abuse treatment facility to...

  1. 24 CFR 960.205 - Drug use by applicants: Obtaining information from drug treatment facility.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    .... This section addresses a PHA's authority to request and obtain information from drug abuse treatment... household member. (2) Drug abuse treatment facility. An entity: (i) That holds itself out as providing, and... consent forms signed by such household member that: (i) Requests any drug abuse treatment facility to...

  2. 24 CFR 960.205 - Drug use by applicants: Obtaining information from drug treatment facility.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    .... This section addresses a PHA's authority to request and obtain information from drug abuse treatment... household member. (2) Drug abuse treatment facility. An entity: (i) That holds itself out as providing, and... consent forms signed by such household member that: (i) Requests any drug abuse treatment facility to...

  3. 24 CFR 960.205 - Drug use by applicants: Obtaining information from drug treatment facility.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    .... This section addresses a PHA's authority to request and obtain information from drug abuse treatment... household member. (2) Drug abuse treatment facility. An entity: (i) That holds itself out as providing, and... consent forms signed by such household member that: (i) Requests any drug abuse treatment facility to...

  4. 24 CFR 960.205 - Drug use by applicants: Obtaining information from drug treatment facility.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    .... This section addresses a PHA's authority to request and obtain information from drug abuse treatment... household member. (2) Drug abuse treatment facility. An entity: (i) That holds itself out as providing, and... consent forms signed by such household member that: (i) Requests any drug abuse treatment facility to...

  5. Crash Test of Three Cessna 172 Aircraft at NASA Langley Research Center's Landing and Impact Research Facility

    NASA Technical Reports Server (NTRS)

    Littell, Justin D.

    2015-01-01

    During the summer of 2015, three Cessna 172 aircraft were crash tested at the Landing and Impact Research Facility (LandIR) at NASA Langley Research Center (LaRC). The three tests simulated three different crash scenarios. The first simulated a flare-to-stall emergency or hard landing onto a rigid surface such as a road or runway, the second simulated a controlled flight into terrain with a nose down pitch on the aircraft, and the third simulated a controlled flight into terrain with an attempt to unsuccessfully recover the aircraft immediately prior to impact, resulting in a tail strike condition. An on-board data acquisition system captured 64 channels of airframe acceleration, along with acceleration and load in two onboard Hybrid II 50th percentile Anthropomorphic Test Devices, representing the pilot and co-pilot. Each test contained different airframe loading conditions and results show large differences in airframe performance. This paper presents test methods used to conduct the crash tests and will summarize the airframe results from the test series.

  6. KENNEDY SPACE CENTER, FLA. - Emergency crew members assess medical needs on “injured” astronauts removed from the orbiter crew compartment mock-up during a “Mode VII” emergency landing simulation at Kennedy Space Center. The purpose of the Mode VII is to exercise emergency preparedness personnel, equipment and facilities in rescuing astronauts from a downed orbiter and providing immediate medical attention. This simulation presents an orbiter that has crashed short of the Shuttle Landing Facility in a wooded area 2-1/2 miles south of Runway 33. Emergency crews are responding to the volunteer astronauts who are simulating various injuries. Rescuers must remove the crew, provide triage and transport to hospitals those who need further treatment. Local hospitals are participating in the exercise.

    NASA Image and Video Library

    2004-02-18

    KENNEDY SPACE CENTER, FLA. - Emergency crew members assess medical needs on “injured” astronauts removed from the orbiter crew compartment mock-up during a “Mode VII” emergency landing simulation at Kennedy Space Center. The purpose of the Mode VII is to exercise emergency preparedness personnel, equipment and facilities in rescuing astronauts from a downed orbiter and providing immediate medical attention. This simulation presents an orbiter that has crashed short of the Shuttle Landing Facility in a wooded area 2-1/2 miles south of Runway 33. Emergency crews are responding to the volunteer astronauts who are simulating various injuries. Rescuers must remove the crew, provide triage and transport to hospitals those who need further treatment. Local hospitals are participating in the exercise.

  7. NPDES Permit: Shiprock Wastewater Treatment Facility, Shiprock, New Mexico

    EPA Pesticide Factsheets

    NPDES Permit, Fact Sheet, and Response to Comments explaining EPA's issue of NPDES Permit No. NN0020621 to the Navajo Tribal Utility Authority Shiprock Wastewater Treatment Facility, Shiprock, San Juan County, New Mexico.

  8. Very high-vacuum heat treatment facility

    NASA Technical Reports Server (NTRS)

    Folkner, W. M.; Moody, M. V.; Richard, J.-P.

    1987-01-01

    A vacuum heat treatment facility, with hot zone dimensions of 12 x 19 x 19 cm, has been designed and constructed at a cost substantially below that of a commercial unit. The design incorporates efficient water cooling and a resistive heating element. A vacuum pressure of 1.5 x 10 to the -8th torr at room temperature has been obtained after baking. The temperature limit is approximately 1900 C. This limit results from the choice of niobium as the hot zone material.

  9. Occurrence of antibiotics in wastewater treatment facilities in Wisconsin, USA.

    PubMed

    Karthikeyan, K G; Meyer, Michael T

    2006-05-15

    Samples from several wastewater treatment facilities in Wisconsin were screened for the presence of 21 antibiotic compounds. These facilities spanned a range of community size served (average daily flow from 0.0212 to 23.6 million gallons/day), secondary treatment processes, geographic locations across the state, and they discharged the treated effluents to both surface and ground waters (for ground water after a soil passage). A total of six antibiotic compounds were detected (1-5 compounds per site), including two sulfonamides (sulfamethazine, sulfamethoxazole), one tetracycline (tetracycline), fluoroquinolone (ciprofloxacin), macrolide (erythromycin-H(2)O) and trimethoprim. The frequency of detection of antibiotics was in the following order: tetracycline and trimethoprim (80%)>sulfamethoxazole (70%)>erythromycin-H(2)O (45%)>ciprofloxacin (40%)>sulfamethazine (10%). However, the soluble concentrations were in the parts-per-billion (ppb) range (treatment facility. The concentrations detected were within an order of magnitude of those reported for similar systems in Europe and Canada: they were within a factor of two in comparison to those reported for Canada but generally lower relative to those measured in wastewater systems in Europe. Only sulfamethoxazole and tetracycline were detected in groundwater monitoring wells adjacent to the treatment systems. Future intensive wastewater monitoring programs in Wisconsin may be limited to the six antibiotic compounds detected in this study.

  10. NPDES Permit for Charlo Wastewater Treatment Facility in Montana

    EPA Pesticide Factsheets

    Under NPDES permit MT-0022551, the Consolidated Charlo-Lake County Water & Sewer District is authorized to discharge from its wastewater treatment facility located in Lake County, Montana to an unnamed swale that runs to Dublin Gulch.

  11. LAND TREATMENT AND THE TOXICITY RESPONSE OF SOIL CONTAMINATED WITH WOOD PRESERVING WASTE

    EPA Science Inventory

    Soils contaminated with wood preserving wastes, including pentachlo-rophenol (PCP) and creosote, are treated at field-scale in an engineered prepared-bed system consisting of two one-acre land treatment units (LTUs). The concentration of selected indicator compounds of treatment ...

  12. Association Between Treatment at High-Volume Facilities and Improved Overall Survival in Soft Tissue Sarcomas.

    PubMed

    Venigalla, Sriram; Nead, Kevin T; Sebro, Ronnie; Guttmann, David M; Sharma, Sonam; Simone, Charles B; Levin, William P; Wilson, Robert J; Weber, Kristy L; Shabason, Jacob E

    2018-03-15

    Soft tissue sarcomas (STS) are rare malignancies that require complex multidisciplinary management. Therefore, facilities with high sarcoma case volume may demonstrate superior outcomes. We hypothesized that STS treatment at high-volume (HV) facilities would be associated with improved overall survival (OS). Patients aged ≥18 years with nonmetastatic STS treated with surgery and radiation therapy at a single facility from 2004 through 2013 were identified from the National Cancer Database. Facilities were dichotomized into HV and low-volume (LV) cohorts based on total case volume over the study period. OS was assessed using multivariable Cox regression with propensity score-matching. Patterns of care were assessed using multivariable logistic regression analysis. Of 9025 total patients, 1578 (17%) and 7447 (83%) were treated at HV and LV facilities, respectively. On multivariable analysis, high educational attainment, larger tumor size, higher grade, and negative surgical margins were statistically significantly associated with treatment at HV facilities; conversely, black race and non-metropolitan residence were negative predictors of treatment at HV facilities. On propensity score-matched multivariable analysis, treatment at HV facilities versus LV facilities was associated with improved OS (hazard ratio, 0.87, 95% confidence interval, 0.80-0.95; P = .001). Older age, lack of insurance, greater comorbidity, larger tumor size, higher tumor grade, and positive surgical margins were associated with statistically significantly worse OS. In this observational cohort study using the National Cancer Database, receipt of surgery and radiation therapy at HV facilities was associated with improved OS in patients with STS. Potential sociodemographic disparities limit access to care at HV facilities for certain populations. Our findings highlight the importance of receipt of care at HV facilities for patients with STS and warrant further study into improving access to

  13. 43 CFR 13.3 - Cooperation in selection of facilities.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 43 Public Lands: Interior 1 2011-10-01 2011-10-01 false Cooperation in selection of facilities. 13.3 Section 13.3 Public Lands: Interior Office of the Secretary of the Interior VENDING FACILITIES OPERATED BY BLIND PERSONS § 13.3 Cooperation in selection of facilities. Upon request from a State...

  14. A Movable Combined Water Treatment Facility for Rainwater Harvesting

    NASA Astrophysics Data System (ADS)

    Zhang, L.; Liao, L.

    2003-12-01

    Alarming water shortage and increased water scarcity world wide has led to increased interests in alternative water sources. Rainwater harvesting is one of them which is getting more and more attention. There is a huge potential for generalization and extension of rainwater harvesting system as an alternative water supply. This is especially important for arid and semi-arid regions where the water shortage blocks further social, economical development. Earlier laboratory experiments and field study showed that harvested rainwater requires treatments of different degrees in order to meet the WHO drinking water standards. The main focus of this study is to ascertain the quality of stored rainwater for drinking purposes with emphasis on water disinfection and pollutants removal. A movable, low-cost, fully functional small scale treatment facility is proposed and tested under simulated field condition. A number of actual and potential hazardous pollutants were identified in the collected water samples together with laboratory test. The corresponding water purification procedure and fresh-keeping methods are discussed. The final proposal of this movable facility needs to be further examined to achieve optimal combined treatment efficiency.

  15. Land Treatment Research and Development Program, Synthesis of Research Results,

    DTIC Science & Technology

    1983-08-01

    at Pack Forest, Washington .......... 22 8. Infiltration test and the relationship between cumulative water uptake and tim e...the chemistry of phos- phorus in land treatment ..................................... 37 18. Schematic diagram of the compartmental water flow model...39 19. Comparison between predicted and measured water content in slow rate soils .................................................. 39 20

  16. Rates of trauma-informed counseling at substance abuse treatment facilities: reports from over 10,000 programs.

    PubMed

    Capezza, Nicole M; Najavits, Lisa M

    2012-04-01

    Trauma-informed treatment increasingly is recognized as an important component of service delivery. This study examined differences in treatment-related characteristics of facilities that offer moderate or high levels of trauma-informed counseling versus those that offer no or low levels of such counseling. Responses from 13,223 substance abuse treatment facilities surveyed in 2009 by the National Survey of Substance Abuse Treatment Services (NSSATS) were used. A majority (66.6%) of facilities reported using trauma counseling sometimes or always or often. Facilities that provided moderate or high levels of trauma counseling were more likely to provide additional treatment services, such as disease testing and specialized group therapy, as well as child care, employment counseling, and other ancillary services. A majority of facilities reported provision of trauma counseling. Additional training and resources may be needed for programs that reported low rates of trauma counseling.

  17. Residential Behavioral Treatment Facilities. 1996 Minnesota Student Survey.

    ERIC Educational Resources Information Center

    Fulkerson, Jayne A.; Harrison, Patricia A.; Beebe, Timothy J.

    This report uses text, graphs, and tables to present findings of a 1996 survey of 575 adolescents voluntarily participating in residential behavioral treatment facilities in Minnesota. Compared with public school students, these adolescents were: 62 percent male, more likely to be of color, especially American Indian, and twice as likely as other…

  18. Electroconvulsive treatment--more than electricity?: An Odyssey of facilities.

    PubMed

    Berg, John E

    2009-12-01

    To investigate whether the practice of electroconvulsive treatment (ECT) today is done in a comparable way in different hospitals on several continents. During visits to the ECT facilities of 14 hospitals on 3 continents, comparisons were made, and responsible health professionals were interviewed using a semistructured guide. It is emphasized that the present article is not the result of a well-structured research, but of reflections after observing a lack of homogeneity among facilities. A total of more than 18,000 modified ECT sessions were given per year in the 14 hospitals. The opinion of the public and regulatory bodies on ECT strongly influences the possibility of giving ECT to patients. Indications for ECT are wider than the cases of depression in most facilities visited. A psychiatrist gives ECT in all but 1 facility. Anesthesia is given by an anesthesiologist in all but 1 facility. A mouthpiece was not used in 2 (or 3) facilities, although the rationale was the same as in facilities using mouthpieces. No facility gave unmodified ECT. Holding on to the patient during seizures was judged unnecessary in 12 of 14 facilities. In severe mental illness, the practice of using ECT seems to have its merit also in cases with debilitating illnesses other than unipolar and bipolar depression. Giving ECT may be done by qualified or specially certified nurses, but the giving of anesthesia should be the realm of the anesthesiologist. Mouthpieces are judged by some facilities to be a superfluous device. The holding of patients during seizure can be omitted. Some of the facilities visited give ECT to a huge number of patients each year. They differ in the practice of ECT and could be the focus of comparative research. Despite the differences observed, and procedures that could be altered, giving ECT in a modified way effectively relieves suffering in the patients.

  19. Algal bioremediation of waste waters from land-based aquaculture using ulva: selecting target species and strains.

    PubMed

    Lawton, Rebecca J; Mata, Leonardo; de Nys, Rocky; Paul, Nicholas A

    2013-01-01

    The optimised reduction of dissolved nutrient loads in aquaculture effluents through bioremediation requires selection of appropriate algal species and strains. The objective of the current study was to identify target species and strains from the macroalgal genus Ulva for bioremediation of land-based aquaculture facilities in Eastern Australia. We surveyed land-based aquaculture facilities and natural coastal environments across three geographic locations in Eastern Australia to determine which species of Ulva occur naturally in this region and conducted growth trials at three temperature treatments on a subset of samples from each location to determine whether local strains had superior performance under local environmental conditions. DNA barcoding using the markers ITS and tufA identified six species of Ulva, with U. ohnoi being the most common blade species and U. sp. 3 the most common filamentous species. Both species occurred at multiple land-based aquaculture facilities in Townsville and Brisbane and multiple strains of each species grew well in culture. Specific growth rates of U. ohnoi and U. sp. 3 were high (over 9% and 15% day(-1) respectively) across temperature treatments. Within species, strains of U. ohnoi had higher growth in temperatures corresponding to local conditions, suggesting that strains may be locally adapted. However, across all temperature treatments Townsville strains had the highest growth rates (11.2-20.4% day(-1)) and Sydney strains had the lowest growth rates (2.5-8.3% day(-1)). We also found significant differences in growth between strains of U. ohnoi collected from the same geographic location, highlighting the potential to isolate and cultivate fast growing strains. In contrast, there was no clearly identifiable competitive strain of filamentous Ulva, with multiple species and strains having variable performance. The fast growth rates and broad geographical distribution of U. ohnoi make this an ideal species to target for

  20. Occurrence of antibiotics in wastewater treatment facilities in Wisconsin, USA

    USGS Publications Warehouse

    Karthikeyan, K.G.; Meyer, M.T.

    2006-01-01

    Samples from several wastewater treatment facilities in Wisconsin were screened for the presence of 21 antibiotic compounds. These facilities spanned a range of community size served (average daily flow from 0.0212 to 23.6 million gallons/day), secondary treatment processes, geographic locations across the state, and they discharged the treated effluents to both surface and ground waters (for ground water after a soil passage). A total of six antibiotic compounds were detected (1-5 compounds per site), including two sulfonamides (sulfamethazine, sulfamethoxazole), one tetracycline (tetracycline), fluoroquinolone (ciprofloxacin), macrolide (erythromycin-H2O) and trimethoprim. The frequency of detection of antibiotics was in the following order: tetracycline and trimethoprim (80%) > sulfamethoxazole (70%) > erythromycin-H2O (45%) > ciprofloxacin (40%) > sulfamethazine (10%). However, the soluble concentrations were in the parts-per-billion (ppb) range (??? 1.3 ??g/L), and importantly were unaffected by the size of the wastewater treatment facility. The concentrations detected were within an order of magnitude of those reported for similar systems in Europe and Canada: they were within a factor of two in comparison to those reported for Canada but generally lower relative to those measured in wastewater systems in Europe. Only sulfamethoxazole and tetracycline were detected in groundwater monitoring wells adjacent to the treatment systems. Future intensive wastewater monitoring programs in Wisconsin may be limited to the six antibiotic compounds detected in this study. ?? 2005 Elsevier B.V. All rights reserved.

  1. Central Facilities Area Sewage Lagoon Evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Giesbrecht, Alan

    2015-03-01

    The Central Facilities Area (CFA) located in Butte County, Idaho at Idaho National Laboratory (INL) has an existing wastewater system to collect and treat sanitary wastewater and non contact cooling water from the facility. The existing treatment facility consists of three cells: Cell 1 has a surface area of 1.7 acres, Cell 2 has a surface area of 10.3 acres, and Cell 3 has a surface area of 0.5 acres. If flows exceed the evaporative capacity of the cells, wastewater is discharged to a 73.5 acre land application site that utilizes a center pivot irrigation sprinkler system. The purpose ofmore » this current study is to update the analysis and conclusions of the December 2013 study. In this current study, the new seepage rate and influent flow rate data have been used to update the calculations, model, and analysis.« less

  2. Bilogical Treatment for Ammonia Oxidation in Drinking Water Facilities

    EPA Science Inventory

    Ammonia is an unregulated compound, but is naturally occurring in many drinking water sources. It is also used by some treatment facilities to produce chloramines for disinfection purposes. Because ammonia is non-toxic, its presence in drinking water is often disregarded. Thro...

  3. Differences between U.S. substance abuse treatment facilities that do and do not offer domestic violence services.

    PubMed

    Cohn, Amy; Najavits, Lisa M

    2014-04-01

    Victimization by and perpetration of domestic violence are associated with co-occurring mental and substance use disorders. This study used data from the National Survey of Substance Abuse Treatment Services to examine differences in organizational factors, treatment approaches offered, and client-level factors among 13,342 substance abuse treatment facilities by whether or not they offered domestic violence services. Only 36% of the facilities offered domestic violence services. Those that offered such services were more likely than those that did not to treat clients with co-occurring disorders. Principal-components analysis reduced eight treatment approaches to two factors: psychosocial services and traditional substance abuse services. Regression models indicated that the frequency with which psychosocial services were offered depended on the percentage of clients with co-occurring disorders who were being treated in the facility and whether or not that facility offered domestic violence services. Specifically, facilities that did not offer domestic violence services and that had a high percentage of clients with co-occurring disorders were more likely to offer psychosocial services than facilities that offered domestic violence services. A larger proportion of facilities offering domestic violence services offered traditional substance abuse treatment services, compared with facilities not offering domestic violence services, but this relationship was not contingent on the percentage of clients with co-occurring disorders at each facility. Improved efforts should be made to tailor treatments to accommodate the links between domestic violence, mental disorders, and substance abuse.

  4. 32 CFR 766.12 - Unauthorized landings.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 32 National Defense 5 2010-07-01 2010-07-01 false Unauthorized landings. 766.12 Section 766.12... DEPARTMENT OF THE NAVY AVIATION FACILITIES BY CIVIL AIRCRAFT § 766.12 Unauthorized landings. An aircraft that... authority, except in a bona fide emergency, is in violation of this part. Civil aircraft landing in...

  5. Radioactive Liquid Waste Treatment Facility: Environmental Information Document

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Haagenstad, H.T.; Gonzales, G.; Suazo, I.L.

    1993-11-01

    At Los Alamos National Laboratory (LANL), the treatment of radioactive liquid waste is an integral function of the LANL mission: to assure U.S. military deterrence capability through nuclear weapons technology. As part of this mission, LANL conducts nuclear materials research and development (R&D) activities. These activities generate radioactive liquid waste that must be handled in a manner to ensure protection of workers, the public, and the environment. Radioactive liquid waste currently generated at LANL is treated at the Radioactive Liquid Waste Treatment Facility (RLWTF), located at Technical Area (TA)-50. The RLWTF is 30 years old and nearing the end ofmore » its useful design life. The facility was designed at a time when environmental requirements, as well as more effective treatment technologies, were not inherent in engineering design criteria. The evolution of engineering design criteria has resulted in the older technology becoming less effective in treating radioactive liquid wastestreams in accordance with current National Pollutant Discharge Elimination System (NPDES) and Department of Energy (DOE) regulatory requirements. Therefore, to support ongoing R&D programs pertinent to its mission, LANL is in need of capabilities to efficiently treat radioactive liquid waste onsite or to transport the waste off site for treatment and/or disposal. The purpose of the EID is to provide the technical baseline information for subsequent preparation of an Environmental Impact Statement (EIS) for the RLWTF. This EID addresses the proposed action and alternatives for meeting the purpose and need for agency action.« less

  6. 78 FR 3913 - Public Land Order No. 7807: Withdrawal of Public Lands for the Camp Michael Monsoor Mountain...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-17

    ..., location, and entry under the general land laws, including the United States mining laws, for a period of... Training Facility. This withdrawal also transfers administrative jurisdiction of the lands to the... entry under the general land laws, including the United States mining laws, but not from leasing under...

  7. Opportunities for Open Automated Demand Response in Wastewater Treatment Facilities in California - Phase II Report. San Luis Rey Wastewater Treatment Plant Case Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thompson, Lisa; Lekov, Alex; McKane, Aimee

    2010-08-20

    This case study enhances the understanding of open automated demand response opportunities in municipal wastewater treatment facilities. The report summarizes the findings of a 100 day submetering project at the San Luis Rey Wastewater Treatment Plant, a municipal wastewater treatment facility in Oceanside, California. The report reveals that key energy-intensive equipment such as pumps and centrifuges can be targeted for large load reductions. Demand response tests on the effluent pumps resulted a 300 kW load reduction and tests on centrifuges resulted in a 40 kW load reduction. Although tests on the facility?s blowers resulted in peak period load reductions ofmore » 78 kW sharp, short-lived increases in the turbidity of the wastewater effluent were experienced within 24 hours of the test. The results of these tests, which were conducted on blowers without variable speed drive capability, would not be acceptable and warrant further study. This study finds that wastewater treatment facilities have significant open automated demand response potential. However, limiting factors to implementing demand response are the reaction of effluent turbidity to reduced aeration load, along with the cogeneration capabilities of municipal facilities, including existing power purchase agreements and utility receptiveness to purchasing electricity from cogeneration facilities.« less

  8. 26 CFR 1.274-7 - Treatment of certain expenditures with respect to entertainment-type facilities.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 26 Internal Revenue 3 2010-04-01 2010-04-01 false Treatment of certain expenditures with respect to entertainment-type facilities. 1.274-7 Section 1.274-7 Internal Revenue INTERNAL REVENUE SERVICE... Treatment of certain expenditures with respect to entertainment-type facilities. If deductions are...

  9. 9 CFR 166.5 - Licensed garbage-treatment facility standards.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 9 Animals and Animal Products 1 2011-01-01 2011-01-01 false Licensed garbage-treatment facility standards. 166.5 Section 166.5 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE... where insects and rodents may breed is prohibited. (b) Equipment used for handling untreated garbage...

  10. Siting industrial waste land disposal facilities in Thailand: A risk based approach

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fingleton, D.J.; Habegger, L.; Peters, R.

    The Thailand Industrial Works Department (IWD) has established a toxic industrial waste Central Treatment and Stabilization Center (CTSC) for textile dyeing and electroplating industries located in the Thonburi region of the Bangkok metropolitan area. Industrial waste is treated, stabilized, and stored at the CTSC. Although the IWD plans to ship the stabilized sludge to the Ratchaburi Province in western Thailand for burial, the location for the land disposal site has not been selected. Assessing the relative health risks from exposure to toxic chemicals released from an industrial waste land disposal site is a complicated, data-intensive process that requires a multidisciplinarymore » approach. This process is further complicated by the unique physical and cultural characteristics exhibited by the rapidly industrializing Thai economy. The purpose of this paper is to describe the research approach taken and to detail the constraints to health risk assessments in Thailand. issues discussed include data availability and quality, effectiveness of control or mitigation methods, cultural differences, and the basic assumptions inherent in many of the risk assessment components.« less

  11. Effect of average flow and capacity utilization on effluent water quality from US municipal wastewater treatment facilities.

    PubMed

    Weirich, Scott R; Silverstein, Joann; Rajagopalan, Balaji

    2011-08-01

    There is increasing interest in decentralization of wastewater collection and treatment systems. However, there have been no systematic studies of the performance of small treatment facilities compared with larger plants. A statistical analysis of 4 years of discharge monthly report (DMR) data from 210 operating wastewater treatment facilities was conducted to determine the effect of average flow rate and capacity utilization on effluent biochemical oxygen demand (BOD), total suspended solids (TSS), ammonia, and fecal coliforms relative to permitted values. Relationships were quantified using generalized linear models (GLMs). Small facilities (40 m³/d) had violation rates greater than 10 times that of the largest facilities (400,000 m³/d) for BOD, TSS, and ammonia. For facilities with average flows less than 40,000 m³/d, increasing capacity utilization was correlated with increased effluent levels of BOD and TSS. Larger facilities tended to operate at flows closer to their design capacity while maintaining treatment suggesting greater efficiency. Copyright © 2011 Elsevier Ltd. All rights reserved.

  12. KENNEDY SPACE CENTER, FLA. - An “injured” rescue worker is lifted into an M-113 armored personnel carrier provided for transportation during a “Mode VII” emergency landing simulation at Kennedy Space Center. The purpose of the Mode VII is to exercise emergency preparedness personnel, equipment and facilities in rescuing astronauts from a downed orbiter and providing immediate medical attention. This simulation presents an orbiter that has crashed short of the Shuttle Landing Facility in a wooded area 2-1/2 miles south of Runway 33. Emergency crews are responding to the volunteer astronauts who are simulating various injuries inside the crew compartment mock-up. Rescuers must remove the crew, provide triage and transport to hospitals those who need further treatment. Local hospitals are participating in the exercise.

    NASA Image and Video Library

    2004-02-18

    KENNEDY SPACE CENTER, FLA. - An “injured” rescue worker is lifted into an M-113 armored personnel carrier provided for transportation during a “Mode VII” emergency landing simulation at Kennedy Space Center. The purpose of the Mode VII is to exercise emergency preparedness personnel, equipment and facilities in rescuing astronauts from a downed orbiter and providing immediate medical attention. This simulation presents an orbiter that has crashed short of the Shuttle Landing Facility in a wooded area 2-1/2 miles south of Runway 33. Emergency crews are responding to the volunteer astronauts who are simulating various injuries inside the crew compartment mock-up. Rescuers must remove the crew, provide triage and transport to hospitals those who need further treatment. Local hospitals are participating in the exercise.

  13. KENNEDY SPACE CENTER, FLA. - Emergency crew members on the ground take hold of a volunteer “astronaut” lowered from the top of the orbiter crew compartment mock-up that is the scene of a “Mode VII” emergency landing simulation at Kennedy Space Center. The purpose of the Mode VII is to exercise emergency preparedness personnel, equipment and facilities in rescuing astronauts from a downed orbiter and providing immediate medical attention. This simulation presents an orbiter that has crashed short of the Shuttle Landing Facility in a wooded area 2-1/2 miles south of Runway 33. Emergency crews are responding to the volunteer astronauts who are simulating various injuries. Rescuers must remove the crew, provide triage and transport to hospitals those who need further treatment. Local hospitals are participating in the exercise.

    NASA Image and Video Library

    2004-02-18

    KENNEDY SPACE CENTER, FLA. - Emergency crew members on the ground take hold of a volunteer “astronaut” lowered from the top of the orbiter crew compartment mock-up that is the scene of a “Mode VII” emergency landing simulation at Kennedy Space Center. The purpose of the Mode VII is to exercise emergency preparedness personnel, equipment and facilities in rescuing astronauts from a downed orbiter and providing immediate medical attention. This simulation presents an orbiter that has crashed short of the Shuttle Landing Facility in a wooded area 2-1/2 miles south of Runway 33. Emergency crews are responding to the volunteer astronauts who are simulating various injuries. Rescuers must remove the crew, provide triage and transport to hospitals those who need further treatment. Local hospitals are participating in the exercise.

  14. KENNEDY SPACE CENTER, FLA. - Emergency crew members help a volunteer “astronaut” onto the ground after being lowered from the top of the orbiter crew compartment mock-up that is the scene of a “Mode VII” emergency landing simulation at Kennedy Space Center. The purpose of the Mode VII is to exercise emergency preparedness personnel, equipment and facilities in rescuing astronauts from a downed orbiter and providing immediate medical attention. This simulation presents an orbiter that has crashed short of the Shuttle Landing Facility in a wooded area 2-1/2 miles south of Runway 33. Emergency crews are responding to the volunteer astronauts who are simulating various injuries. Rescuers must remove the crew, provide triage and transport to hospitals those who need further treatment. Local hospitals are participating in the exercise.

    NASA Image and Video Library

    2004-02-18

    KENNEDY SPACE CENTER, FLA. - Emergency crew members help a volunteer “astronaut” onto the ground after being lowered from the top of the orbiter crew compartment mock-up that is the scene of a “Mode VII” emergency landing simulation at Kennedy Space Center. The purpose of the Mode VII is to exercise emergency preparedness personnel, equipment and facilities in rescuing astronauts from a downed orbiter and providing immediate medical attention. This simulation presents an orbiter that has crashed short of the Shuttle Landing Facility in a wooded area 2-1/2 miles south of Runway 33. Emergency crews are responding to the volunteer astronauts who are simulating various injuries. Rescuers must remove the crew, provide triage and transport to hospitals those who need further treatment. Local hospitals are participating in the exercise.

  15. KENNEDY SPACE CENTER, FLA. - Emergency crew members lower a volunteer “astronaut” from the top of the orbiter crew compartment mock-up that is the scene of a “Mode VII” emergency landing simulation at Kennedy Space Center. The purpose of the Mode VII is to exercise emergency preparedness personnel, equipment and facilities in rescuing astronauts from a downed orbiter and providing immediate medical attention. This simulation presents an orbiter that has crashed short of the Shuttle Landing Facility in a wooded area 2-1/2 miles south of Runway 33. Emergency crews are responding to the volunteer “astronauts” who are simulating various injuries. Rescuers must remove the crew, provide triage and transport to hospitals those who need further treatment. Local hospitals are participating in the exercise.

    NASA Image and Video Library

    2004-02-18

    KENNEDY SPACE CENTER, FLA. - Emergency crew members lower a volunteer “astronaut” from the top of the orbiter crew compartment mock-up that is the scene of a “Mode VII” emergency landing simulation at Kennedy Space Center. The purpose of the Mode VII is to exercise emergency preparedness personnel, equipment and facilities in rescuing astronauts from a downed orbiter and providing immediate medical attention. This simulation presents an orbiter that has crashed short of the Shuttle Landing Facility in a wooded area 2-1/2 miles south of Runway 33. Emergency crews are responding to the volunteer “astronauts” who are simulating various injuries. Rescuers must remove the crew, provide triage and transport to hospitals those who need further treatment. Local hospitals are participating in the exercise.

  16. An Effective Web Presence for Substance Abuse Treatment Facilities.

    PubMed

    Link, Thomas W; Hefner, Jennifer L; Ford, Eric W; Huerta, Timothy R

    2016-01-01

    Website development for health care has only been prevalent in the last two and a half decades. The first websites were electronic versions of brochures providing hardly any interaction with the consumer or potential consumer. The percentage of consumers that use the internet during the decision-making process for health care providers continues to rise. As a result, the websites of health care providers are becoming more of a representation of the facility and creating an organizational image rather than a brochure-like informational page. The purpose of this study was to analyze substance abuse treatment center's websites in the State of California with the goal of informing the management of substance abuse centers regarding an effective and inexpensive means to closing the marketing gaps in the industry. This brief research report presents the results of employing an automated web-crawler to assess website quality along five dimensions: accessibility, content, marketing, technology, and usability score. The sample mean scores for all dimensions were between 4 and 6 on a 10-point scale. On average larger facilities had higher quality websites. The low mean scores on these dimensions indicate that that substance abuse centers have significant room for improvement of their website's. Efficiently spending marketing funds to increase the effectiveness of a treatment center's website can be a low cost way for even small facilities to increase market competitiveness.

  17. 43 CFR 3140.6 - Use of additional lands.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 43 Public Lands: Interior 2 2013-10-01 2013-10-01 false Use of additional lands. 3140.6 Section... additional lands. (a) The authorized officer may noncompetitively lease additional lands for ancillary facilities in a Special Tar Sand Area that are needed to support any operations necessary for the recovery of...

  18. 43 CFR 3140.6 - Use of additional lands.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 43 Public Lands: Interior 2 2012-10-01 2012-10-01 false Use of additional lands. 3140.6 Section... additional lands. (a) The authorized officer may noncompetitively lease additional lands for ancillary facilities in a Special Tar Sand Area that are needed to support any operations necessary for the recovery of...

  19. 43 CFR 3140.6 - Use of additional lands.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 43 Public Lands: Interior 2 2014-10-01 2014-10-01 false Use of additional lands. 3140.6 Section... additional lands. (a) The authorized officer may noncompetitively lease additional lands for ancillary facilities in a Special Tar Sand Area that are needed to support any operations necessary for the recovery of...

  20. Variance Assistance Document: Land Disposal Restrictions Treatability Variances and Determinations of Equivalent Treatment

    EPA Pesticide Factsheets

    This document provides assistance to those seeking to submit a variance request for LDR treatability variances and determinations of equivalent treatment regarding the hazardous waste land disposal restrictions program.

  1. 26 CFR 1.274-7 - Treatment of certain expenditures with respect to entertainment-type facilities.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 26 Internal Revenue 3 2014-04-01 2014-04-01 false Treatment of certain expenditures with respect to entertainment-type facilities. 1.274-7 Section 1.274-7 Internal Revenue INTERNAL REVENUE SERVICE... § 1.274-7 Treatment of certain expenditures with respect to entertainment-type facilities. If...

  2. 26 CFR 1.274-7 - Treatment of certain expenditures with respect to entertainment-type facilities.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 26 Internal Revenue 3 2012-04-01 2012-04-01 false Treatment of certain expenditures with respect to entertainment-type facilities. 1.274-7 Section 1.274-7 Internal Revenue INTERNAL REVENUE SERVICE... § 1.274-7 Treatment of certain expenditures with respect to entertainment-type facilities. If...

  3. 26 CFR 1.274-7 - Treatment of certain expenditures with respect to entertainment-type facilities.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 26 Internal Revenue 3 2013-04-01 2013-04-01 false Treatment of certain expenditures with respect to entertainment-type facilities. 1.274-7 Section 1.274-7 Internal Revenue INTERNAL REVENUE SERVICE... § 1.274-7 Treatment of certain expenditures with respect to entertainment-type facilities. If...

  4. 26 CFR 1.274-7 - Treatment of certain expenditures with respect to entertainment-type facilities.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 26 Internal Revenue 3 2011-04-01 2011-04-01 false Treatment of certain expenditures with respect to entertainment-type facilities. 1.274-7 Section 1.274-7 Internal Revenue INTERNAL REVENUE SERVICE... § 1.274-7 Treatment of certain expenditures with respect to entertainment-type facilities. If...

  5. 43 CFR 17.217 - Existing facilities.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 43 Public Lands: Interior 1 2011-10-01 2011-10-01 false Existing facilities. 17.217 Section 17.217... facilities. (a) Accessibility. A recipient shall operate each program or activity so that when each part is... not require a recipient to make each of its existing facilities or every part of a facility accessible...

  6. 25 CFR 502.23 - Facility license.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 25 Indians 2 2010-04-01 2010-04-01 false Facility license. 502.23 Section 502.23 Indians NATIONAL....23 Facility license. Facility license means a separate license issued by a tribe to each place, facility, or location on Indian lands where the tribe elects to allow class II or III gaming. [73 FR 6029...

  7. RCRA, superfund and EPCRA hotline training module. Introduction to: Land disposal restrictions (40 cfr parts 268) updated July 1996

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1996-07-01

    The module presents an overview of the land disposal restrictions (LDR) program. It defines the basic terms and describes the structure of the LDR regulations. It identifies the statutory basis for LDR and describes the applicability of LDR. It explains how EPA sets treatment standards and identifies treatment standards for wastes subject to land disposal restrictions and cites the CFR section. It describes and identifies how exemptions and variances from treatment requirements are obtained, including federal register citations. It defines generator and Treatment, Storage, and Disposal Facility (TSDF) requirements under the LDR program. It summarizes the schedule of existing restrictionsmore » and the plan for restricting newly identified wastes.« less

  8. NPDES Permit for Fort Carson Wastewater Treatment Facility in Colorado

    EPA Pesticide Factsheets

    Under NPDES permit no. CO-0021181 the United States Department of the Army, Fort Carson, in authorized to discharge from its sanitary wastewater treatment facility in El Paso County, Colorado, to Clover Ditch, a tributary of Fountain Creek.

  9. Lunar Landing Testing at NASA Langley

    NASA Image and Video Library

    1965-06-18

    Lunar Landing Testing at NASA Langley. Lunar Landing Testing at NASA Langley. A simulated environment that contributed in a significant way to the success of Apollo project was the Lunar Landing Research Facility, an imposing 250 foot high, 400 foot long gantry structure that became operational in 1965. Published in the book "Space Flight Revolution" NASA SP-4308 pg. 376

  10. 14 CFR 1204.1403 - Available airport facilities.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... AUTHORITY AND POLICY Use of NASA Airfield Facilities by Aircraft Not Operated for the Benefit of the Federal Government § 1204.1403 Available airport facilities. The facilities available vary at each NASA Installation having an airfield. The airport facilities available are: (a) Shuttle Landing Facility—(1) Runways...

  11. 14 CFR 1204.1403 - Available airport facilities.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... AUTHORITY AND POLICY Use of NASA Airfield Facilities by Aircraft Not Operated for the Benefit of the Federal Government § 1204.1403 Available airport facilities. The facilities available vary at each NASA Installation having an airfield. The airport facilities available are: (a) Shuttle Landing Facility—(1) Runways...

  12. NPDES Permit for Yellowtail Dam Wastewater Treatment Facility in Montana

    EPA Pesticide Factsheets

    Under NPDES permit MT-0022993, the U.S. Bureau of Reclamation is authorized to discharge from its wastewater treatment facility located at the Yellowtail Dam Field Office in Big Horn County, Montana, to the Yellowtail Afterbay Reservoir/Bighorn River.

  13. 76 FR 18244 - Public Land Order No. 7760; Extension of Public Land Order No. 6839; Alaska

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-01

    ... Barrow Magnetic Observatory (formerly known as the Barrow Geomagnetic Observatory). This order also... Barrow Base Line Observatory and the Barrow Magnetic Observatory, respectively. The land continues to be... facility encumbers 45 acres for the Barrow Magnetic Observatory. The withdrawal for both facilities is...

  14. Malaria prevalence and treatment of febrile patients at health facilities and medicine retailers in Cameroon.

    PubMed

    Mangham, Lindsay J; Cundill, Bonnie; Achonduh, Olivia A; Ambebila, Joel N; Lele, Albertine K; Metoh, Theresia N; Ndive, Sarah N; Ndong, Ignatius C; Nguela, Rachel L; Nji, Akindeh M; Orang-Ojong, Barnabas; Wiseman, Virginia; Pamen-Ngako, Joelle; Mbacham, Wilfred F

    2012-03-01

    To investigate the quality of malaria case management in Cameroon 5 years after the adoption of artemisinin-based combination therapy (ACT). Treatment patterns were examined in different types of facility, and the factors associated with being prescribed or receiving an ACT were investigated. A cross-sectional cluster survey was conducted among individuals of all ages who left public and private health facilities and medicine retailers in Cameroon and who reported seeking treatment for a fever. Prevalence of malaria was determined by rapid diagnostic tests (RDTs) in consenting patients attending the facilities and medicine retailers. Among the patients, 73% were prescribed or received an antimalarial, and 51% were prescribed or received an ACT. Treatment provided to patients significantly differed by type of facility: 65% of patients at public facilities, 55% of patients at private facilities and 45% of patients at medicine retailers were prescribed or received an ACT (P = 0.023). The odds of a febrile patient being prescribed or receiving an ACT were significantly higher for patients who asked for an ACT (OR = 24.1, P < 0.001), were examined by the health worker (OR = 1.88, P = 0.021), had not previously sought an antimalarial for the illness (OR = 2.29, P = 0.001) and sought treatment at a public (OR = 3.55) or private facility (OR = 1.99, P = 0.003). Malaria was confirmed in 29% of patients and 70% of patients with a negative result were prescribed or received an antimalarial. Malaria case management could be improved. Symptomatic diagnosis is inefficient because two-thirds of febrile patients do not have malaria. Government plans to extend malaria testing should promote rational use of ACT; though, the introduction of rapid diagnostic testing needs to be accompanied by updated clinical guidelines that provide clear guidance for the treatment of patients with negative test results. © 2011 Blackwell Publishing Ltd.

  15. Operation, Maintenance and Management of Wastewater Treatment Facilities: A Bibliography of Technical Documents.

    ERIC Educational Resources Information Center

    Himes, Dottie

    This is an annotated bibliography of wastewater treatment manuals. Fourteen manuals are abstracted including: (1) A Planned Maintenance Management System for Municipal Wastewater Treatment Plants; (2) Anaerobic Sludge Digestion, Operations Manual; (3) Emergency Planning for Municipal Wastewater Treatment Facilities; (4) Estimating Laboratory Needs…

  16. 43 CFR 2651.6 - Airport and air navigation facilities.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 43 Public Lands: Interior 2 2014-10-01 2014-10-01 false Airport and air navigation facilities... Village Selections § 2651.6 Airport and air navigation facilities. (a) Every airport and air navigation.... (b) The surface of all other lands of existing airport sites, airway beacons, or other navigation...

  17. 43 CFR 2651.6 - Airport and air navigation facilities.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 43 Public Lands: Interior 2 2012-10-01 2012-10-01 false Airport and air navigation facilities... Village Selections § 2651.6 Airport and air navigation facilities. (a) Every airport and air navigation.... (b) The surface of all other lands of existing airport sites, airway beacons, or other navigation...

  18. 43 CFR 2651.6 - Airport and air navigation facilities.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 43 Public Lands: Interior 2 2013-10-01 2013-10-01 false Airport and air navigation facilities... Village Selections § 2651.6 Airport and air navigation facilities. (a) Every airport and air navigation.... (b) The surface of all other lands of existing airport sites, airway beacons, or other navigation...

  19. Evolution of area access safety training required for gaining access to Space Shuttle launch and landing facilities

    NASA Technical Reports Server (NTRS)

    Willams, M. C.

    1985-01-01

    Assuring personnel and equipment are fully protected during the Space Shuttle launch and landing operations has been a primary concern of NASA and its associated contractors since the inception of the program. A key factor in support of this policy has been the area access safety training requirements for badging of employees assigned to work on Space Shuttle Launch and Facilities. This requirement was targeted for possible cost savings and the transition of physical on-site walkdowns to the use of television tapes has realized program cost savings while continuing to fully satisfy the area access safety training requirements.

  20. NPDES Permit for Yellowtail Visitor Center Wastewater Treatment Facility in Montana

    EPA Pesticide Factsheets

    NPDES permit MT-0029106 for United States Bureau of Reclamation discharge from its Yellowtail Visitor Center wastewater treatment facility into the Bighorn Lake/Bighorn River in Big Horn County, Montana.

  1. Columbia (STS-50) Landing

    NASA Technical Reports Server (NTRS)

    1992-01-01

    As the orbiter Columbia (STS-50) rolled down Runway 33 of Kennedy Space Center's (KSC) Shuttle Landing Facility, its distinctively colored drag chute deployed to slow down the spaceship. This landing marked OV-102's first end-of-mission landing at KSC and the tenth in the program, and the second shuttle landing with the drag chute. Edwards Air Force Base, CA, was the designated prime for the landing of Mission STS-50, but poor weather necessitated the switch to KSC after a one-day extension of the historic flight. STS-50 was the longest in Shuttle program historyo date, lasting 13 days, 19 hours, 30 minutes and 4 seconds. A crew of seven and the USML-1 were aboard.

  2. Construction bidding cost of KSC's space shuttle facilities

    NASA Technical Reports Server (NTRS)

    Brown, Joseph Andrew

    1977-01-01

    The bidding cost of the major Space Transportation System facilities constructed under the responsibility of the John F. Kennedy Space Center (KSC) is described and listed. These facilities and Ground Support Equipment (GSE) are necessary for the receiving, assembly, testing, and checkout of the Space Shuttle for launch and landing missions at KSC. The Shuttle launch configuration consists of the Orbiter, the External Tank, and the Solid Rocket Boosters (SRB). The reusable Orbiter and SRB's is the major factor in the program that will result in lowering space travel costs. The new facilities are the Landing Facility; Orbiter Processing Facility; Orbiter Approach and Landing Test Facility (Dryden Test Center, California); Orbiter Mating Devices; Sound Suppression Water System; and Emergency Power System for LC-39. Also, a major factor was to use as much Apollo facilities and hardware as possible to reduce the facilities cost. The alterations to existing Apollo facilities are the VAB modifications; Mobile Launcher Platforms; Launch Complex 39 Pads A and B (which includes a new concept - the Rotary Service Structure), which was featured in ENR, 3 Feb. 1977, 'Hinged Space Truss will Support Shuttle Cargo Room'; Launch Control Center mods; External Tank and SRB Processing and Storage; Fluid Test Complex mods; O&C Spacelab mods; Shuttle mods for Parachute Facility; SRB Recovery and Disassembly Facility at Hangar 'AF'; and an interesting GSE item - the SRB Dewatering Nozzle Plug Sets (Remote Controlled Submarine System) used to inspect and acquire for reuse of SRB's.

  3. Analysis of factors of treatment completion in dots health facilities in metro Manila, Philippines: a case-control study.

    PubMed

    Lagrada, Leizel P; Uehara, Naruo; Kawahara, Kazuo

    2008-12-01

    STUDY BACKGROUND AND OBJECTIVES: The Philippines is one of the 22 countries with high TB burden. DOTS was adopted not only by purely public providers (PP) but also by public-private mix (PPM) facilities. This study aims to identify the patient and facility factors that promote completion of TB treatment in DOTS facilities in an urban setting. The study also explores the difference between the PP and PPM DOTS facilities in terms of case management and treatment outcomes. [Methods] A case control study was done by interviewing 394 patients sampled from TB cohort report between 2003 and 2005 of 14 DOTS facilities in Metro Manila. Statistical analyses used include chi-square test and logistic regression analysis. Being female and aged 30-44 (OR = 7.04; 95% CI 1.12-44.35), unemployed (OR = 2.73; 95% CI 1.18-6.33), being above per capita poverty threshold (OR = 2.03; 95% CI 1.03-3.99), having experienced at least one of the signs and symptoms of TB (OR = 4.64; 95% CI 1.29-16.67), taking the medication at health facility (OR = 3.87; 95% CI 1.48-10.16) and patient's understanding of DOT (OR = 2.67; 95% CI 1.37-5.23) predict TB treatment completion. Public-private mix type of DOTS facility was also significantly associated with completing treatment (chi 2 (1) = 54.76, p = 0.000). Patient factors like middle-aged female compared to female aged more than 60, being above per capita poverty threshold, unemployment and having experienced at least one signs and symptoms of TB and facility factors like providing treatment at the facility and explaining the DOT to patient increase the likelihood of completing treatment. Thus, encouraging patients to take their medication at the facility and helping the patients understand the importance of DOT can increase TB treatment completion. The seemingly better DOTS implementation and treatment outcomes by the PPM must be evaluated further through cost effectiveness and efficiency studies.

  4. Hazardous air pollutant (HAP) emission characterization of sewage treatment facilities in Korea.

    PubMed

    Kang, Kyoung-Hee; Dong, Jong-In

    2010-04-01

    Until recently, nearly all sewage treatment-related regulations and researches have focused on the removal of the conventional and toxic pollutants from liquid effluents. The discharge of toxic compounds to the atmosphere has been implicitly regarded as a way of removal or destruction. During sewage treatment, the fate mechanism of volatilization/stripping, sorption and biotransformation primarily determines the fate of volatile HAPs. The objectives of this study are to investigate the emission characteristics of HAPs, which are generated from the liquid surface of sewage treatment facilities, by using an emission isolation flux chamber. HAP emissions increased at the inlet of the aerobic chamber during summer due to the relatively high atmospheric temperature. The percent ratio of flux for toluene reached its peak in winter, accounting for 33.6-34.2% of the total, but decreased to 25.1-28.6% in summer. In autumn, trichloroethene (TCE) was the highest, recording 17.6-18.1%, with chloroform and toluene showing similar levels. It seems that the ratio of chlorinated hydrocarbons increases in both summer and autumn because the chamber temperature during that time is higher than winter. This study is the initial study to investigate the emission characteristics of volatile HAPs emitted from domestic sewage treatment facilities to the air in Korea. Therefore, the isolation flux chamber will be used as an emission estimations tool to measure HAPs from sewage treatment facilities and may be applied to develop the emission factor and national source inventory of HAPs.

  5. Guidance: Demonstrating Compliance with the Land Disposal Restrictions (LDR) Alternative Soil Treatment Standards

    EPA Pesticide Factsheets

    This guidance provides suggestions and perspectives on how members of the regulated community, states, and the public can demonstrate compliance with the alternative treatment standards for certain contaminated soils that will be land disposed.

  6. NPDES Permit for Soap Creek Associates Wastewater Treatment Facility in Montana

    EPA Pesticide Factsheets

    Under National Pollutant Discharge Elimination System permit number MT-0023183, Soap Creek Associates, Inc. is authorized to discharge from its wastewater treatment facility located in West, Bighorn County, Montana, to Soap Creek.

  7. NPDES Permit for Lame Deer Lagoon Wastewater Treatment Facility in Montana

    EPA Pesticide Factsheets

    Final permit authorizes the Northern Cheyenne Utilities Commission to discharge from its Lame Deer Lagoon wastewater treatment facility located in Rosebud County, Montana to Lame Deer Creek, a tributary to Rosebud Creek.

  8. NPDES Permit for City of Polson Wastewater Treatment Facility in Montana

    EPA Pesticide Factsheets

    Under National Pollutant Discharge Elimination System permit number MT-0020559, the City of Polson is authorized to discharge from its wastewater treatment facility located in Lake County, Montana to the Flathead River.

  9. 43 CFR 41.410 - Comparable facilities.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 43 Public Lands: Interior 1 2011-10-01 2011-10-01 false Comparable facilities. 41.410 Section 41... Basis of Sex in Education Programs or Activities Prohibited § 41.410 Comparable facilities. A recipient may provide separate toilet, locker room, and shower facilities on the basis of sex, but such...

  10. Characteristics of U.S. Substance Abuse Treatment Facilities Offering HIV Services: Results From a National Survey.

    PubMed

    Cohn, Amy; Stanton, Cassandra; Elmasry, Hoda; Ehlke, Sarah; Niaura, Ray

    2016-06-01

    Substance use disorders are common among persons with HIV/AIDS. This study examined the prevalence and correlates of the provision of four HIV services in a national sample of substance abuse treatment facilities. Data were from the 2011 National Survey of Substance Abuse Treatment Services. Prevalence estimates indicated that 28% of facilities offered HIV testing, 26% early intervention, 58% HIV/AIDS education, and 8% special programs for HIV/AIDS. Facilities offering inpatient substance abuse care were more than six times as likely to offer HIV testing but not more likely to offer any other type of HIV service. Facilities offering methadone treatment were 2.5 times more likely to offer HIV services. Given the high rates of substance use among persons with HIV, the prevalence of facilities offering HIV services was low in most domains, with different barriers identified in multivariable models. Integrating comprehensive HIV prevention, testing, and support services into programs that address substance abuse is needed.

  11. Cross-Training Laboratory Animal Care Personnel in Physically Separate Animal Facilities at a Land-Grant Institution.

    PubMed

    Henze, Tonja M; Allison, Sarah O; Criley, Jennifer M; Myers, Sara J; Goodly, Lyndon J

    2016-01-01

    The University of Illinois at Urbana-Champaign maintains physically separated animal care facilities under centralized management by the Division of Animal Resources. As part of a land-grant institution, the animal care and use program operates several animal units in key locations for specific disciplines within the campus, all of which have the core mission to teach, conduct research, and engage in public service. Populations of research animals vary with the levels of research funding, the number of research investigators on staff, research direction, and animal availability. Accordingly, the requirement for animal care staffing in each unit may vary widely also. To best use the existing animal care staff and remain fiscally responsible, cross-training of staff was implemented to allow staff to travel from units with small animal populations to units with larger populations or short-term staffing shortages. Here we detail and describe the system we used to assess the needs for cross-training, identify the staff to train, and implement the training plan. We believe this information will assist other programs, particularly those with large or complex organization (for example, land-grant institutions) that experience similar fluctuations in animal use.

  12. Maintenance of Airport Visual Aid Facilities

    DOT National Transportation Integrated Search

    1982-08-26

    This advisory circular provides recommended guidelines for maintenance of : airport visual aid facilities. Since the function of such facilities is to : assist in the safe and efficient movement of aircraft during landing, takeoff, : and taxiing mane...

  13. 32 CFR 766.12 - Unauthorized landings.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 32 National Defense 5 2011-07-01 2011-07-01 false Unauthorized landings. 766.12 Section 766.12 National Defense Department of Defense (Continued) DEPARTMENT OF THE NAVY MISCELLANEOUS RULES USE OF DEPARTMENT OF THE NAVY AVIATION FACILITIES BY CIVIL AIRCRAFT § 766.12 Unauthorized landings. An aircraft that...

  14. The Michoud Assembly Facility (MAF)

    NASA Technical Reports Server (NTRS)

    2000-01-01

    NASA's Michoud Assembly Facility, located in eastern New Orleans, Louisiana, is an 832 acre site that is a government-owned, contractor-operated component of the George C. Marshall Space Flight Center (MSFC). The facility was acquired by NASA in 1961 at the recommendation of Dr. Wernher von Braun and his rocket team in Huntsville Alabama. The cavernous plant served as the assembly facility for the Saturn launch vehicles and most recently the external tank (ET) used for the Space Shuttle Program. The facility features one of the world's biggest manufacturing plants with 43 acres under one roof and a port with deep-water access for the transportation of large space structures. When completed, space hardware is towed on a barge across the Gulf of Mexico, around Florida and up to Kennedy Space Center. The original tract of land was part of a 34,500 acre French Royal land grant to local merchant, Gilbert Antoine de St. Maxent in 1763. Later, the land was acquired by French transplant Antoine Michoud, the son of Napoleon's Administrator of Domains, who moved to the city in 1827. Michoud operated a sugar cane plantation and refinery on the site until his death in 1863. His heirs continued operating the refinery and kept the original St. Maxent estate intact into the 20th century. Visible on the right, is one of two brick smokestacks from the original refinery that still stand before the Michoud facility today.

  15. The Michoud Assembly Facility (MAF)

    NASA Technical Reports Server (NTRS)

    2000-01-01

    NASA's Michoud Assembly Facility, located in eastern New Orleans, Louisiana, is an 832 acre site that is a government-owned, contractor-operated component of the George C. Marshall Space Flight Center (MSFC). The facility was acquired by NASA in 1961 at the recommendation of Dr. Wernher von Braun and his rocket team in Huntsville Alabama. The cavernous plant served as the assembly facility for the Saturn launch vehicles and most recently the external tank (ET) used for the Space Shuttle Program. The facility features one of the world's biggest manufacturing plants with 43 acres under one roof and a port with deep-water access for the transportation of large space structures. When completed, space hardware is towed on a barge across the Gulf of Mexico, around Florida and up to Kennedy Space Center. The original tract of land was part of a 34,500 acre French Royal land grant to local merchant, Gilbert Antoine de St. Maxent in 1763. Later, the land was acquired by French transplant Antoine Michoud, the son of Napoleon's Administrator of Domains, who moved to the city in 1827. Michoud operated a sugar cane plantation and refinery on the site until his death in 1863. His heirs continued operating the refinery and kept the original St. Maxent estate intact into the 20th century. Two brick smokestacks from the original refinery still stand before the Michoud facility today.

  16. Land Plus Aquatic Therapy Versus Land-Based Rehabilitation Alone for the Treatment of Balance Dysfunction in Parkinson Disease: A Randomized Controlled Study With 6-Month Follow-Up.

    PubMed

    Palamara, Grazia; Gotti, Francesco; Maestri, Roberto; Bera, Rossana; Gargantini, Roberto; Bossio, Fabiola; Zivi, Ilaria; Volpe, Daniele; Ferrazzoli, Davide; Frazzitta, Giuseppe

    2017-06-01

    To assess whether a specific land-based physical intervention with the inclusion of aquatic therapy is more effective than land-based rehabilitation alone for the treatment of balance dysfunction in patients with Parkinson disease (PD), immediately after therapy and at 6 months' follow-up. Randomized controlled study with 6-month follow-up. A PD and brain injury rehabilitation department in a general hospital. Patients (N=34) with moderate-stage PD. Seventeen patients underwent a land-based rehabilitation protocol called multidisciplinary intensive rehabilitation treatment (MIRT), and 17 underwent MIRT plus aquatic therapy (MIRT-AT). The primary outcome measure was the Berg Balance Scale (BBS); secondary outcome measures were the Unified Parkinson Disease Rating Scale parts II and III (UPDRS II/III) and the Timed Up and Go (TUG) test. These measures were assessed in both groups at admission, at discharge, and after 6 months. BBS improved after treatment in both groups. Even though no statistically significant difference between groups was observed at each observation time, BBS scores at follow-up were significantly higher than at baseline in MIRT-AT patients. Both groups also showed an improvement in UPDRS II/III and TUG at the end of treatment compared with baseline, but these findings were lost at the 6-month follow-up. Aquatic therapy added to land-based rehabilitation could provide a contribution to the treatment of balance dysfunction in patients with moderate-stage PD. Copyright © 2017 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  17. NPDES Permit for Woodcock Home Addition Wastewater Treatment Facility in Montana

    EPA Pesticide Factsheets

    Under NPDES permit MT-0030554, the Salish and Kootenai Housing Authority is authorized to discharge from its Woodcock Home Addition Wastewater Treatment Facility in Lake County, Montana, to a swale draining to Middle Crow Creek.

  18. The consistency between treatments provided to nursing facility residents and orders on the physician orders for life-sustaining treatment form.

    PubMed

    Hickman, Susan E; Nelson, Christine A; Moss, Alvin H; Tolle, Susan W; Perrin, Nancy A; Hammes, Bernard J

    2011-11-01

    To evaluate the consistency between treatments provided and Physician Orders for Life-Sustaining Treatment (POLST) orders. Retrospective chart abstraction. Stratified, random sample of 90 nursing facilities in Oregon, Wisconsin, and West Virginia. Eight hundred seventy living and deceased nursing facility residents aged 65 and older with a minimum 60-day stay. Chart data about POLST form orders and related treatments over a 60-day period were abstracted. Decision rules were created to determine whether the rationale for each treatment was consistent with POLST orders. Most residents (85.2%) had the same POLST form in place during the review period. A majority of treatments provided to residents with orders for comfort measures only (74.3%) and limited antibiotics (83.3%) were consistent with POLST orders because they were primarily comfort focused rather than life-prolonging, but antibiotics were provided to 32.1% of residents with orders for no antibiotics. Overall consistency rates between treatments and POLST orders were high for resuscitation (98%), medical interventions (91.1%), and antibiotics (92.9%) and modest for feeding tubes (63.6%). In all, POLST orders were consistent with treatments provided 94.0% of the time. With the exception of feeding tubes and antibiotic use in residents with orders for no antibiotics, the use of medical treatments was nearly always consistent with POLST orders to provide or withhold life-sustaining interventions. The POLST program is a useful tool for ensuring that the treatment preferences of nursing facility residents are honored. © 2011, Copyright the Authors Journal compilation © 2011, The American Geriatrics Society.

  19. 43 CFR 17.550 - Program accessibility: Existing facilities.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 43 Public Lands: Interior 1 2011-10-01 2011-10-01 false Program accessibility: Existing facilities....550 Program accessibility: Existing facilities. (a) General. The agency shall operate each program or... its existing facilities or every part of a facility accessible to and usable by handicapped persons...

  20. Do drug treatment facilities increase clients' exposure to potential neighborhood-level triggers for relapse? A small-area assessment of a large, public treatment system.

    PubMed

    Jacobson, Jerry O

    2006-03-01

    Research on drug treatment facility locations has focused narrowly on the issue of geographic proximity to clients. We argue that neighborhood conditions should also enter into the facility location decision and illustrate a formal assessment of neighborhood conditions at facilities in a large, metropolitan area, taking into account conditions clients already face at home. We discuss choice and construction of small-area measures relevant to the drug treatment context, including drug activity, disadvantage, and violence as well as statistical comparisons of clients' home and treatment locations with respect to these measures. Analysis of 22,707 clients discharged from 494 community-based outpatient and residential treatment facilities that received public funds during 1998-2000 in Los Angeles County revealed no significant mean differences between home and treatment neighborhoods. However, up to 20% of clients are exposed to markedly higher levels of disadvantage, violence, or drug activity where they attend treatment than where they live, suggesting that it is not uncommon for treatment locations to increase clients' exposure to potential environmental triggers for relapse. Whereas on average both home and treatment locations exhibit higher levels of these measures than the household locations of the general population, substantial variability in public treatment clients' home neighborhoods calls into question the notion that they hail exclusively from poor, high drug activity areas. Shortcomings of measures available for neighborhood assessment of treatment locations and implications of the findings for other areas of treatment research are also discussed.

  1. Characterization of the Shuttle Landing Facility as a laser range for testing and evaluation of EO systems

    NASA Astrophysics Data System (ADS)

    Stromqvist Vetelino, Frida; Borbath, Michael R.; Andrews, Larry C.; Phillips, Ronald L.; Burdge, Geoffrey L.; Chin, Peter G.; Galus, Darren J.; Wayne, David; Pescatore, Robert; Cowan, Doris; Thomas, Frederick

    2005-08-01

    The Shuttle Landing Facility runway at the Kennedy Space Center in Cape Canaveral, Florida is almost 5 km long and 100 m wide. Its homogeneous environment makes it a unique and ideal place for testing and evaluating EO systems. An experiment, with the goal of characterizing atmospheric parameters on the runway, was conducted in June 2005. Weather data was collected and the refractive index structure parameter was measured with a commercial scintillometer. The inner scale of turbulence was inferred from wind speed measurements and surface roughness. Values of the crosswind speed obtained from the scintillometer were compared with wind measurements taken by a weather station.

  2. Navajo Tribal Utility Authority Shiprock Wastewater Treatment Facility; Draft NPDES Permit

    EPA Pesticide Factsheets

    EPA is proposing to issue a NPDES permit (No. NN0020621) to Navajo Tribal Utility Authority (NTUA) for the Shiprock wastewater treatment facility in San Juan County, New Mexico, within the northeastern portion of the Navajo Nation.

  3. Assessment of Physical, Chemical, and Hydrologic Factors Affecting the Infiltration of Treated Wastewater in theNew Jersey Coastal Plain, with Emphasis on theHammonton Land Application Facility

    USGS Publications Warehouse

    Reilly, Timothy J.; Romanok, Kristin M.; Tessler, Steven; Fischer, Jeffrey M.

    2010-01-01

    A hydrogeologic and water-quality investigation of the Hammonton Land Application Facility (Hammonton LAF) in Hammonton, New Jersey, was conducted to determine the factors that impede the infiltration of treated wastewater and to assess the potential for similar conditions to exist elsewhere in the Coastal Plain of New Jersey (particularly within the Pinelands National Reserve). Gamma logs, sediment cores, and hydraulic-profile testing indicate that extensive fine-grained strata and iron-cemented sands underlying the Hammonton LAF may impede infiltration and lead to the perching of diluted treated wastewater. Perched water was observed in augured holes adjacent to infiltration trenches, and analysis of wastewater loading and infiltration data indicates that infiltration trenches may receive lateral flow from multiple perched-water sources. Analysis of water-quality properties characteristic of treated wastewater show that although infiltrated wastewater is reaching the underlying aquifer, lengthy holding times and a long recharge pathway greatly reduce the concentrations of nitrate, boron, and many organic compounds typical of wastewater. Conditions at two currently operating facilities and one potential future facility in the New Jersey Coastal Plain were compared to those at the Hammonton Land Application Facility (LAF). Facilities operating as designed are not underlain by the restrictive strata that exist at the Hammonton LAF. Careful characterization of the geology and hydrology of the unsaturated zone underlying infiltration structures of future facilities in the New Jersey Coastal Plain and similar hydrogeologic settings will help to avoid constructing infiltration structures over or within low-hydraulic-conductivity strata that will decrease infiltration rates.

  4. Estimation of marginal costs at existing waste treatment facilities.

    PubMed

    Martinez-Sanchez, Veronica; Hulgaard, Tore; Hindsgaul, Claus; Riber, Christian; Kamuk, Bettina; Astrup, Thomas F

    2016-04-01

    address and include costs in existing waste facilities in decision-making may unintendedly lead to higher overall costs at societal level. To avoid misleading conclusions, economic assessment of alternative SWM solutions should not only consider potential costs associated with alternative treatment but also include marginal costs associated with existing facilities. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. 46 CFR 108.237 - Fuel storage facilities.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... AND EQUIPMENT Construction and Arrangement Helicopter Facilities § 108.237 Fuel storage facilities. (a) Helicopter fuel storage tanks must be installed as far as practicable from— (1) The landing area; and (2...

  6. 14 CFR § 1204.1403 - Available airport facilities.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... AUTHORITY AND POLICY Use of NASA Airfield Facilities by Aircraft Not Operated for the Benefit of the Federal Government § 1204.1403 Available airport facilities. The facilities available vary at each NASA Installation having an airfield. The airport facilities available are: (a) Shuttle Landing Facility—(1) Runways...

  7. 2000 JOURNAL ARTICLES FROM LRPCD (TREATMENT AND DESTRUCTION BRANCH, LAND REMEDIATION AND POLLUTION CONTROL DIVISION, NRMRL)

    EPA Science Inventory

    The Treatment and Destruction Branch (TDB) of NRMRL's Land Remediation and Pollution Control Division (LRPCD)produces and publishes highly specialized technical and scientific documents relating to TDB's research. TDB conducts bioremediation and physical/chemical treatment resear...

  8. Radar multipath study for rain-on-radome experiments at the Aircraft Landing Dynamics Facility

    NASA Technical Reports Server (NTRS)

    Mackenzie, Anne I.; Staton, Leo D.

    1990-01-01

    An analytical study to determine the feasibility of a rain-on-radome experiment at the Aircraft Landing Dynamics Facility (ALDF) at the Langley Research Center is described. The experiment would measure the effects of heavy rain on the transmission of X-band weather radar signals, looking in particular for sources of anomalous attenuation. Feasibility is determined with regard to multipath signals arising from the major structural components of the ALDF. A computer program simulates the transmit and receive antennas, direct-path and multipath signals, and expected attenuation by rain. In the simulation, antenna height, signal polarization, and rainfall rate are variable parameters. The study shows that the rain-on-radome experiment is feasible with regard to multipath signals. The total received signal, taking into account multipath effects, could be measured by commercially available equipment. The study also shows that horizontally polarized signals would produce better experimental results than vertically polarized signals.

  9. Design and Shielding of Radiotherapy Treatment Facilities; IPEM Report 75, 2nd Edition

    NASA Astrophysics Data System (ADS)

    Horton, Patrick; Eaton, David

    2017-07-01

    Design and Shielding of Radiotherapy Treatment Facilities provides readers with a single point of reference for protection advice to the construction and modification of radiotherapy facilities. The book assembles a faculty of national and international experts on all modalities including megavoltage and kilovoltage photons, brachytherapy and high-energy particles, and on conventional and Monte Carlo shielding calculations. This book is a comprehensive reference for qualified experts and radiation-shielding designers in radiation physics and also useful to anyone involved in the design of radiotherapy facilities.

  10. Social work services in Army medical treatment facilities: are they reorganizing?

    PubMed

    Hamlin, E R; Pehrson, K L; Gemmill, R

    1996-01-01

    The end of the Cold War and the fall of Communism in Europe resulted in profound changes in U.S. defense policy. Those changes led to dramatic reductions in personnel and programs within the Army. The Army Medical Department (AMEDD) is also being reduced in size and reorganized. At the same time, the AMEDD is facing escalating health care costs associated with demand and access to medical care. Social work services in Army medical treatment facilities are being directly affected by these system changes. Therefore, the question is raised whether changes in the organization and delivery of social work services are being initiated or anticipated. To what extent are social work chiefs of service involved in these decisions at the medical treatment facility level, and what are the positive and negative effects of reorganization on social work staff and the clients they serve?

  11. 10 CFR 61.51 - Disposal site design for land disposal.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 2 2011-01-01 2011-01-01 false Disposal site design for land disposal. 61.51 Section 61.51 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) LICENSING REQUIREMENTS FOR LAND DISPOSAL OF RADIOACTIVE WASTE Technical Requirements for Land Disposal Facilities § 61.51 Disposal site design for land...

  12. 10 CFR 61.51 - Disposal site design for land disposal.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 2 2014-01-01 2014-01-01 false Disposal site design for land disposal. 61.51 Section 61.51 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) LICENSING REQUIREMENTS FOR LAND DISPOSAL OF RADIOACTIVE WASTE Technical Requirements for Land Disposal Facilities § 61.51 Disposal site design for land...

  13. 10 CFR 61.51 - Disposal site design for land disposal.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 2 2013-01-01 2013-01-01 false Disposal site design for land disposal. 61.51 Section 61.51 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) LICENSING REQUIREMENTS FOR LAND DISPOSAL OF RADIOACTIVE WASTE Technical Requirements for Land Disposal Facilities § 61.51 Disposal site design for land...

  14. 10 CFR 61.51 - Disposal site design for land disposal.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 2 2012-01-01 2012-01-01 false Disposal site design for land disposal. 61.51 Section 61.51 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) LICENSING REQUIREMENTS FOR LAND DISPOSAL OF RADIOACTIVE WASTE Technical Requirements for Land Disposal Facilities § 61.51 Disposal site design for land...

  15. 10 CFR 61.51 - Disposal site design for land disposal.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 2 2010-01-01 2010-01-01 false Disposal site design for land disposal. 61.51 Section 61.51 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) LICENSING REQUIREMENTS FOR LAND DISPOSAL OF RADIOACTIVE WASTE Technical Requirements for Land Disposal Facilities § 61.51 Disposal site design for land...

  16. 1997 JOURNAL ARTICLES FROM LRPCD (TREATMENT AND DESTRUCTION BRANCH, LAND REMEDIATION AND POLLUTION CONTROL DIVISION, NRMRL)

    EPA Science Inventory

    The Treatment and Destruction Branch (TDB) of NRMRL's Land Remediation and Pollution Control Division (LRPCD) produces and publishes highly technical and scientific documents relating to TDB's research. TDB conducts bioremediation and physical/chemical treatment research. The res...

  17. 1996 JOURNAL ARTICLES FROM LRPCD (TREATMENT AND DESTRUCTION BRANCH, LAND REMEDIATION AND POLLUTION CONTROL DIVISION, NRMRL)

    EPA Science Inventory

    The Treatment and Destruction Branch (TDB) of NRMRL's Land Remediation and Pollution Control Division (LRPCD) produces and publishes highly technical and scientific articles relating to TDB's research. TDB conducts bioremediation and physical/chemical treatment research. The rese...

  18. 1998 JOURNAL ARTICLES FROM LRPCD (TREATMENT AND DESTRUCTION BRANCH, LAND REMEDIATION AND POLLUTION CONTROL DIVISION, NRMRL)

    EPA Science Inventory

    The Treatment and Destruction Branch (TDB) of NRMRL's Land Remediation and Pollution Control Division (LRPCD) produces and publishes highly technical and scientific documents relating to TDB's research. TDB conducts bioremediation and physical/chemical treatment research. The res...

  19. 1999 JOURNAL ARTICLES FROM LRPCD (TREATMENT AND DESTRUCTION BRANCH, LAND REMEDIATION AND POLLUTION CONTROL DIVISION, NRMRL)

    EPA Science Inventory

    The Treatment and Destruction Branch (TDB) of NRMRL's Land Remediation and Pollution Control Division (LRPCD) produces and publishes highly technical and scientific documents relating to TDB's research. TDB conducts bioremediation and physical/chemical treatment research. The res...

  20. Development of an Integrated Leachate Treatment Solution for the Port Granby Waste Management Facility - 12429

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Conroy, Kevin W.; Vandergaast, Gerald

    2012-07-01

    The Port Granby Project (the Project) is located near the north shore of Lake Ontario in the Municipality of Clarington, Ontario, Canada. The Project consists of relocating approximately 450,000 m{sup 3} of historic Low-Level Radioactive Waste (LLRW) and contaminated soil from the existing Port Granby Waste Management Facility (WMF) to a proposed Long-Term Waste Management Facility (LTWMF) located adjacent to the WMF. The LTWMF will include an engineered waste containment facility, a Wastewater Treatment Plant (WTP), and other ancillary facilities. A series of bench- and pilot-scale test programs have been conducted to identify preferred treatment processes to be incorporated intomore » the WTP to treat wastewater generated during the construction, closure and post-closure periods at the WMF/LTWMF. (authors)« less

  1. Infection control challenges in deployed US military treatment facilities.

    PubMed

    Hospenthal, Duane R; Crouch, Helen K

    2009-04-01

    Personnel sustaining combat-related injuries in current overseas conflicts continue to have their care complicated by infections caused by multidrug-resistant organisms, including Acinetobacter, Klebsiella, and Pseudomonas. Although presumed to be due to multiple factors both within and outside of the combat theater, concern has been raised about the difficulties in establishing and maintaining standard infection control (IC) practices in deployed medical treatment facilities and in the evacuation of the injured back to the United States. Level III facilities (hospitals capable of holding patients >72 hours) in Iraq and Afghanistan and the evacuation system from Iraq to the continental US were reviewed by an expert IC-infectious disease team. All reviewed facilities had established IC programs, but these were staffed by personnel with limited IC experience, often without perceived adequate time dedicated to perform their duties, and without uniform levels of command emphasis or support. Proper hand hygiene between patients was not always ideal. Isolation and cohorting of patients to decrease multidrug-resistant organism colonization and infection varied among facilities. Review of standard operating procedures found variability among institutions and in quality of these documents. Application of US national and theater-specific guidelines and of antimicrobial control measures also varied among facilities. Effective IC practices are often difficult to maintain in modern US hospitals. In the deployed setting, with ever-changing personnel in a less than optimal practice environment, IC is even more challenging. Standardization of practice with emphasis on the basics of IC practice (e.g., hand hygiene and isolation procedures) needs to be emplaced and maintained in the deployed setting.

  2. Utilization Management in Department of Defense Military Treatment Facilities

    DTIC Science & Technology

    1992-07-01

    Health Affairs) Mendez (1992) clearly states that his plan is for the military health services system’s quality assessment and criteria to become more...also worthy of note that second surgical opinions are not part of Assistant Secretary of Defense (Health Affairs) Mendez ’ (1992) memonrandur on...Affairs) Mendez ’ (1992) quality management policy already states that military medical treatment facilities will begin to implement utilization

  3. Opportunities for Energy Efficiency and Open Automated Demand Response in Wastewater Treatment Facilities in California -- Phase I Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lekov, Alex; Thompson, Lisa; McKane, Aimee

    This report summarizes the Lawrence Berkeley National Laboratory?s research to date in characterizing energy efficiency and automated demand response opportunities for wastewater treatment facilities in California. The report describes the characteristics of wastewater treatment facilities, the nature of the wastewater stream, energy use and demand, as well as details of the wastewater treatment process. It also discusses control systems and energy efficiency and automated demand response opportunities. In addition, several energy efficiency and load management case studies are provided for wastewater treatment facilities.This study shows that wastewater treatment facilities can be excellent candidates for open automated demand response and thatmore » facilities which have implemented energy efficiency measures and have centralized control systems are well-suited to shift or shed electrical loads in response to financial incentives, utility bill savings, and/or opportunities to enhance reliability of service. Control technologies installed for energy efficiency and load management purposes can often be adapted for automated demand response at little additional cost. These improved controls may prepare facilities to be more receptive to open automated demand response due to both increased confidence in the opportunities for controlling energy cost/use and access to the real-time data.« less

  4. EFFECT OF LAND TREATMENT ON THE MUTAGENICITY OF MILWAUKEE HARBOR SEDIMENT [POSTER PRESENTATION

    EPA Science Inventory

    Sediment from the Milwaukee harbor is known to be contaminated with PAHs and PCBs. A pilot-scale study was conducted to evaluate the potential of land treatment to detoxify these contaminants, as determined by several chemical and biological endpoints, including mutagenicity. T...

  5. Bilateral waste-water land-treatment research by China and the US EPA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leach, L.E.; Duan, Z.B.; Wang, S.T.

    1991-01-01

    The study was conducted to evaluate the rapid infiltration (R.I.) method of land treatment as a partial solution to wastewater treatment and reuse for the 0.45 billion cu m/yr (15.75 billion cu ft/yr) of safe irrigation water needed by the year 2000. Chinese environmental scientists and water supply managers are considering the use of the technology for diluting high concentrations of nitrate in the ground water while simultaneously recharging severely overdrafted aquifers. The wastewater used in the study contained synthetic organic compounds found on EPA's list of priority pollutants. During the development of EPA's Land Treatment Design Manuals, research wasmore » terminated before a thorough evaluation of the treatability of these compounds could be completed. Therefore, during the study, an evaluation of R.I. systems ability to treat selected priority pollutants as well as fecal coliform bacteria was carried out in the interest of RSKERL's research objectives. Even though the research was focused on operations to optimize the removal of various nitrogen species from primary effluent, the normal wastewater parameters of BOD, COD, SS, Total - P, and TOC were also studied. The volatile organic compounds most prominent in the wastewater, dichloroethene, dichloroethane, chloroform and carbon tetrachloride were also evaluated for treatability in the cooperative study.« less

  6. Multidisciplinary pain facility treatment outcome for pain-associated fatigue.

    PubMed

    Fishbain, David A; Lewis, John; Cole, Brandly; Cutler, Brian; Smets, Eve; Rosomoff, Hubert; Rosomoff, Rennee Steele

    2005-01-01

    Fatigue is frequently found in chronic pain patients (CPPs) and may be etiologically related to the presence of pain. Fishbain et al. have recently demonstrated that chronic low back pain (LBP) and chronic neck pain patients are more fatigued than controls. The purpose of this study was to determine whether chronic LBP- and chronic neck pain-associated fatigue responded to multidisciplinary multimodal treatment not specifically targeted to the treatment of fatigue. A total of 85 chronic LBP and 33 chronic neck pain patients completed the Multidimensional Fatigue Inventory (MFI), Neuropathic Pain Scale (NPS), and Beck Depression Inventory on admission. In addition, an information tool was completed on each CPP by the senior author. This tool listed demographic information, primary and secondary pain diagnoses, Diagnostic and Statistical Manual of Mental Disorders, 4th Edition (DSM-IV) psychiatric diagnoses assigned, pain location, pain precipitating event, type of injury, years in pain, number of surgeries, type of surgery, type of pain pattern, opioids consumed per day in morphine equivalents, worker compensation status, and whether, according to the clinical examination, the CPP had a neuropathic pain component. At completion of the multidisciplinary multimodal treatment, each CPP again completed the MFI. Student's t-test was utilized to test for statistical changes on the MFI five scales from pre- to post-treatment. Pearson and point-biserial correlations were utilized to determine which variables significantly correlated with MFI change scores. Variables found significant at less than or equal to 0.01 were utilized in a stepwise aggression analysis to find variables predictive of change in MFI scores. Multidisciplinary pain facility. Chronic LBP and chronic neck pain patients. Multidisciplinary multimodal treatment significantly improved CPP fatigue as measured by the MFI. The available variables utilized to predict fatigue best explained only a small percentage

  7. Gaps in the implementation of antenatal syphilis detection and treatment in health facilities across sub-Saharan Africa.

    PubMed

    Kanyangarara, Mufaro; Walker, Neff; Boerma, Ties

    2018-01-01

    Syphilis in pregnancy is an under-recognized public health problem, especially in sub-Saharan Africa which accounts for over 60% of the global burden of syphilis. If left untreated, more than half of maternal syphilis cases will result in adverse pregnancy outcomes including stillbirth and fetal loss, neonatal death, prematurity or low birth weight, and neonatal infections. Achieving universal coverage of antenatal syphilis screening and treatment has been the focus of the global campaign for the elimination of mother-to-child transmission of syphilis. However, little is known about the availability of antenatal syphilis screening and treatment across sub-Saharan Africa. The objective of this study was to estimate the 'likelihood of appropriate care' for antenatal syphilis screening and treatment by analyzing health facility surveys and household surveys conducted from 2010 to 2015 in 12 sub-Saharan African countries. In this secondary data analysis, we linked indicators of health facility readiness to provide antenatal syphilis detection and treatment from Service Provision Assessments (SPAs) and Service Availability and Readiness Assessments (SARAs) to indicators of ANC use from the Demographic and Health Surveys (DHS) to compute estimates of the 'likelihood of appropriate care'. Based on data from 5,593 health facilities that reported offering antenatal care (ANC) services, the availability of syphilis detection and treatment in ANC facilities ranged from 2% to 83%. The availability of syphilis detection and treatment was substantially lower in ANC facilities in West Africa compared to the other sub-regions. Levels of ANC attendance were high (median 94.9%), but only 27% of ANC attendees initiated care at less than 4 months gestation. We estimated that about one in twelve pregnant women received ANC early (<4 months) at a facility ready to provide syphilis detection and treatment (median 8%, range 7-32%). The largest implementation bottleneck identified was low

  8. Facility-level, state, and financial factors associated with changes in the provision of smoking cessation services in US substance abuse treatment facilities: Results from the National Survey of Substance Abuse Treatment Services 2006 to 2012.

    PubMed

    Cohn, Amy; Elmasry, Hoda; Niaura, Ray

    2017-06-01

    Cigarette smoking is common among patients in substance abuse treatment. Tobacco control programs have advocated for integrated tobacco dependence treatment into behavioral healthcare, including within substance abuse treatment facilities (SATFs) to reduce the public health burden of tobacco use. This study used data from seven waves (2006 to 2012) of the National Survey of Substance Abuse Treatment Services (n=94,145) to examine state and annual changes in the provision of smoking cessation services within US SATFs and whether changes over time could be explained by facility-level (private vs public ownership, receipt of earmarks, facility admissions, acceptance of government insurance) and state-level factors (cigarette tax per pack, smoke free policies, and percent of CDC recommended tobacco prevention spending). Results showed that the prevalence of SATFs offering smoking cessation services increased over time, from 13% to 65%. The amount of tax per cigarette pack, accepting government insurance, government (vs private) ownership, facility admissions, and CDC recommended tobacco prevention spending (per state) were the strongest correlates of the provision of smoking cessation programs in SATFs. Facilities that received earmarks were less likely to provide cessation services. Adult smoking prevalence and state-level smoke free policies were not significant correlates of the provision of smoking cessation services over time. Policies aimed at increasing the distribution of tax revenues to cessation services in SATFs may offset tobacco-related burden among those with substance abuse problems. Copyright © 2017. Published by Elsevier Inc.

  9. 46 CFR 108.237 - Fuel storage facilities.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Fuel storage facilities. 108.237 Section 108.237... AND EQUIPMENT Construction and Arrangement Helicopter Facilities § 108.237 Fuel storage facilities. (a) Helicopter fuel storage tanks must be installed as far as practicable from— (1) The landing area; and (2...

  10. 46 CFR 108.237 - Fuel storage facilities.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Fuel storage facilities. 108.237 Section 108.237... AND EQUIPMENT Construction and Arrangement Helicopter Facilities § 108.237 Fuel storage facilities. (a) Helicopter fuel storage tanks must be installed as far as practicable from— (1) The landing area; and (2...

  11. 46 CFR 108.237 - Fuel storage facilities.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Fuel storage facilities. 108.237 Section 108.237... AND EQUIPMENT Construction and Arrangement Helicopter Facilities § 108.237 Fuel storage facilities. (a) Helicopter fuel storage tanks must be installed as far as practicable from— (1) The landing area; and (2...

  12. 46 CFR 108.237 - Fuel storage facilities.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Fuel storage facilities. 108.237 Section 108.237... AND EQUIPMENT Construction and Arrangement Helicopter Facilities § 108.237 Fuel storage facilities. (a) Helicopter fuel storage tanks must be installed as far as practicable from— (1) The landing area; and (2...

  13. NPDES Permit for Keller Transport, Inc. Groundwater Remediation Treatment Facility in Montana

    EPA Pesticide Factsheets

    Under National Pollutant Discharge Elimination System permit number MT0030805, Keller Transport, Inc. is authorized to discharge from its groundwater remediation treatment facility in Lake County, Montana, to Flathead Lake.

  14. Potable Water Treatment Facility General Permit (PWTF GP) for Massachusetts & New Hampshire

    EPA Pesticide Factsheets

    Documents, links & contacts for the Notice of Availability of the draft NPDES General Permit for Discharges from Potable Water Treatment Facilities in Massachusetts (MAG640000) and New Hampshire (NHG640000).

  15. ORION Project-(SPLASH) Structural Passive Landing Attenuation fo

    NASA Image and Video Library

    2011-07-12

    ORION Project-(SPLASH) Structural Passive Landing Attenuation for Survivability of Human Crew (BTA) Boiler Plate Test Article Water Impact Test-Pot Phase"0" Test Tested at the Hydro Impact Basin at the Landing and Impact Research Facility (Gantry)

  16. Travel Distance to Cancer Treatment Facilities in the Deep South.

    PubMed

    Wills, Mary J; Whitman, Marilyn V; English, Thomas M

    Despite ongoing efforts to improve rural healthcare, the health problems facing rural communities persist. The lack of healthcare providers and infrastructure in rural areas has been linked to a number of negative consequences. Among the elderly rural population, the lack of proximal access presents greater barriers because many elderly people are further limited in their ability to travel and pay for services. In the Deep South specifically, rural residents experience limited access to care and overall poor health outcomes. With cancer in particular, the Deep South has been dubbed the "cancer belt," faring far worse in prevalence and mortality rates than other areas of the country. The present study examines the average travel distance for rural elderly patients residing in the Deep South who are receiving treatment for prostate, breast, or colorectal cancer. We analyzed Medicare claims data of beneficiaries residing in the five Deep South states who had received a primary diagnosis of prostate, breast, or colorectal cancer, with a service date ranging from January 1, 2011, through December 31, 2014. The findings reveal that rural Medicare beneficiaries in the Deep South travel significantly greater distances than do their urban counterparts. In addition, travel distances to prostate cancer treatment facilities are significantly greater than those to breast or colorectal cancer treatment facilities. With cancer incidence predicted to increase, the need to reduce travel distances to treatment is vital in efforts to curb the mortality rate in the Deep South.

  17. STS-83 landing views

    NASA Image and Video Library

    2016-08-16

    STS083-S-010 (8 April 1997) --- The main landing gear of the Space Shuttle Columbia touches down on the Shuttle Landing Facility (SLF) runway at the Kennedy Space Center (KSC), after completing almost four days of a scheduled 16-day mission in Earth-orbit. A problem with one of three fuel cells led to an early landing for the seven-member Microgravity Science Laboratory 1 (MSL-1) crew. Touchdown occurred at 1:33:11 p.m. (EDT), April 8, 1997. Onboard Columbia were James D. Halsell, Jr., Susan L. Still, Janice E. Voss, Donald A. Thomas, Michael L. Gernhardt, Roger K. Crouch and Gregory T. Linteris.

  18. Continuous quality improvement in substance abuse treatment facilities: How much does it cost?

    PubMed

    Hunt, Priscillia; Hunter, Sarah B; Levan, Deborah

    2017-06-01

    Continuous quality improvement (CQI) has grown in the U.S. since the 1970s, yet little is known about the costs to implement CQI in substance abuse treatment facilities. This paper is part of a larger group randomized control trial in a large urban county evaluating the impact of Plan-Study-Do-Act (PDSA)-CQI designed for community service organizations (Hunter, Ober, Paddock, Hunt, & Levan, 2014). Operated by one umbrella organization, each of the eight facilities of the study, four residential and four outpatient substance abuse treatment facilities, selected their own CQI Actions, including administrative- and clinical care-related Actions. Using an activity-based costing approach, we collected labor and supplies and equipment costs directly attributable to CQI Actions over a 12-month trial period. Our study finds implementation of CQI and meeting costs of this trial per facility were approximately $2000 to $10,500 per year ($4500 on average), or $10 to $60 per admitted client. We provide a description of the sources of variation in these costs, including differing intensity of the CQI Actions selected, which should help decision makers plan use of PDSA-CQI. Copyright © 2017. Published by Elsevier Inc.

  19. Treatment compliance and challenges among tuberculosis patients across selected health facilities in Osun State Nigeria.

    PubMed

    Ajao, K O; Ogundun, O A; Afolabi, O T; Ojo, T O; Atiba, B P; Oguntunase, D O

    2014-12-01

    Tuberculosis (TB) is a major public health problem in the world and Africa has approximately one quarter of the world's cases. One of the greatest challenges facing most TB programmes is the non-compliance to TB treatment among TB patients. This study aimed at determining the challenges of management of tuberculosis (TB) across selected Osun State health facilities. The study employed a descriptive cross-sectional design. A semi-structured questionnaire was used to collect data from 102 TB patients in the health facilities. The instrument measured socio-demographic variables, patient related factors, socio-economic variables, health care system related factors to TB disease and treatment. Data were analysed and summarized using descriptive and inferential statistics. Statistical significance was placed at p < 0.05. TB patients who had no formal education (χ2 = 12.941, p < 0.05), who were smoking during treatment (χ2 = 13.194, p < 0.001), who consumed alcohol during TB treatment (χ2 = 6.371, p < 0.05) and those who were HIV positive (χ2 = 23.039, p < 0.001) significantly failed to comply with TB treatment. TB patients who waited for one hour or more at heath facilities (χ2 = 21.761, p < 0.001), who reported that TB treatment should be stopped before six month (χ2 = 9.804, p < 0.05) or when patient felt better (χ2 = 35.185, p < 0.001) and travelled for 10 km or more (χ2 = 13.610, p < 0.001) significantly failed to comply with TB treatment. This study concluded that non-compliance rate to tuberculosis treatment among TB patients in this study is high. Both health facility and patient-related factors were largely responsible.

  20. Treatment of systematic errors in land data assimilation systems

    NASA Astrophysics Data System (ADS)

    Crow, W. T.; Yilmaz, M.

    2012-12-01

    Data assimilation systems are generally designed to minimize the influence of random error on the estimation of system states. Yet, experience with land data assimilation systems has also revealed the presence of large systematic differences between model-derived and remotely-sensed estimates of land surface states. Such differences are commonly resolved prior to data assimilation through implementation of a pre-processing rescaling step whereby observations are scaled (or non-linearly transformed) to somehow "match" comparable predictions made by an assimilation model. While the rationale for removing systematic differences in means (i.e., bias) between models and observations is well-established, relatively little theoretical guidance is currently available to determine the appropriate treatment of higher-order moments during rescaling. This talk presents a simple analytical argument to define an optimal linear-rescaling strategy for observations prior to their assimilation into a land surface model. While a technique based on triple collocation theory is shown to replicate this optimal strategy, commonly-applied rescaling techniques (e.g., so called "least-squares regression" and "variance matching" approaches) are shown to represent only sub-optimal approximations to it. Since the triple collocation approach is likely infeasible in many real-world circumstances, general advice for deciding between various feasible (yet sub-optimal) rescaling approaches will be presented with an emphasis of the implications of this work for the case of directly assimilating satellite radiances. While the bulk of the analysis will deal with linear rescaling techniques, its extension to nonlinear cases will also be discussed.

  1. An Experimental Investigation of Damaged Arresting Gear Tapes for the Langley Aircraft Landing Dynamics Facility

    NASA Technical Reports Server (NTRS)

    Mason, Angela J.

    1999-01-01

    An experimental investigation was performed on damaged arresting gear tapes at the Langley Aircraft Landing Dynamics Facility. The arrestment system uses five pairs of tapes to bring the test carriage to a halt. The procedure used to determine when to replace the tapes consists of a close evaluation of each of the 10 tapes after each run. During this evaluation, each tape is examined thoroughly and any damage observed on the tape is recorded. If the damaged tape does not pass the inspection, the tape is replaced with a new one. For the past 13 years, the most commonly seen damage types are edge fray damage and transverse damage. Tests were conducted to determine the maximum tensile strength of a damaged arresting gear tape specimen. The data indicate that tapes exhibiting transverse damage can withstand higher loads than tapes with edge fray damage.

  2. ORION Project-(SPLASH) Structural Passive Landing Attenuation fo

    NASA Image and Video Library

    2011-07-21

    ORION Project-(SPLASH) Structural Passive Landing Attenuation for Survivability of Human Crew (BTA) Boiler Plate Test Article Water Impact Test-Pot Phase"0" Test POT#2 Tested at the Hydro Impact Basin at the Landing and Impact Research Facility (Gantry)

  3. ORION Project-(SPLASH) Structural Passive Landing Attenuation fo

    NASA Image and Video Library

    2011-12-13

    ORION Project-(SPLASH) Structural Passive Landing Attenuation for Survivability of Human Crew (BTA) Boiler Plate Test Article Water Impact Test-Pit Phase 4 Test or Pit 4 Tested at the Hydro Impact Basin at the Landing and Impact Research Facility (Gantry)

  4. Association Between Facility-Level Utilization of Non-pharmacologic Chronic Pain Treatment and Subsequent Initiation of Long-Term Opioid Therapy.

    PubMed

    Carey, Evan P; Nolan, Charlotte; Kerns, Robert D; Ho, P Michael; Frank, Joseph W

    2018-05-01

    Expert guidelines recommend non-pharmacologic treatments and non-opioid medications for chronic pain and recommend against initiating long-term opioid therapy (LTOT). We examined whether veterans with incident chronic pain receiving care at facilities with greater utilization of non-pharmacologic treatments and non-opioid medications are less likely to initiate LTOT. Retrospective cohort study PARTICIPANTS: Veterans receiving primary care from a Veterans Health Administration facility with incident chronic pain between 1/1/2010 and 12/31/2015 based on either of 2 criteria: (1) persistent moderate-to-severe patient-reported pain and (2) diagnoses "likely to represent" chronic pain. The independent variable was facility-level utilization of pain-related treatment modalities (non-pharmacologic, non-opioid medications, LTOT) in the prior calendar year. The dependent variable was patient-level initiation of LTOT (≥ 90 days within 365 days) in the subsequent year, adjusting for patient characteristics. Among 1,094,569 veterans with incident chronic pain from 2010 to 2015, there was wide facility-level variation in utilization of 10 pain-related treatment modalities, including initiation of LTOT (median, 16%; range, 5-32%). Veterans receiving care at facilities with greater utilization of non-pharmacologic treatments were less likely to initiate LTOT in the year following incident chronic pain. Conversely, veterans receiving care at facilities with greater non-opioid and opioid medication utilization were more likely to initiate LTOT; this association was strongest for past year facility-level LTOT initiation (adjusted rate ratio, 2.10; 95% confidence interval, 2.06-2.15, top vs. bottom quartile of facility-level LTOT initiation in prior calendar year). Facility-level utilization patterns of non-pharmacologic, non-opioid, and opioid treatments for chronic pain are associated with subsequent patient-level initiation of LTOT among veterans with incident chronic pain

  5. NPDES Permit for City of Wagner Wastewater Treatment Facility in South Dakota

    EPA Pesticide Factsheets

    Under NPDES permit SD-0020184, the City of Wagner, South Dakota is authorized to discharge from its wastewater treatment facility in Charles Mix County, South Dakota, to an unnamed tributary of Choteau Creek.

  6. NPDES Permit for Town of Hot Springs Wastewater Treatment Facility in Montana

    EPA Pesticide Factsheets

    Under NPDES permit MT0020591, the Town of Hot Springs, Montana, is authorized to discharge from its wastewater treatment facility located in Sanders County, Montana, to a ditch discharging to Hot Springs Creek.

  7. STS-77 crew examine tires after landing

    NASA Technical Reports Server (NTRS)

    1996-01-01

    KENNEDY SPACE CENTER, FLA. -- STS-77 Mission Specialists Daniel W. Bursch, Andrew S. W. Thomas and Marc Garneau (who represents the Canadian Space Agency) examine the orbiter Endeavour's tires after an end-of-mission landing at 7:09:18 a.m. EDT, May 29, on Runway 33 of KSC's Shuttle Landing Facility. Assisting them at left is Lockheed Martin Space Operations mechanical technician Mark Seawright, who as a member of the Orbiter Recovery Convoy team is involved with post-landing safety assessments and landing gear checkout.

  8. KENNEDY SPACE CENTER, FLA. - A rescue team carries an “injured” astronaut toward the helicopter for transportation to a local hospital. They are all taking part in a “Mode VII” emergency landing simulation at Kennedy Space Center. The purpose of the Mode VII is to exercise emergency preparedness personnel, equipment and facilities in rescuing astronauts from a downed orbiter and providing immediate medical attention. This simulation presents an orbiter that has crashed short of the Shuttle Landing Facility in a wooded area 2-1/2 miles south of Runway 33. Emergency crews are responding to the volunteer astronauts who are simulating various injuries inside the crew compartment mock-up. Rescuers must remove the crew, provide triage and transport to hospitals those who need further treatment. Local hospitals are participating in the exercise. Emergency crews are responding to the volunteer astronauts who are simulating various injuries inside the crew compartment mock-up. Rescuers must remove the crew, provide triage and transport to hospitals those who need further treatment. Local hospitals are participating in the exercise.

    NASA Image and Video Library

    2004-02-18

    KENNEDY SPACE CENTER, FLA. - A rescue team carries an “injured” astronaut toward the helicopter for transportation to a local hospital. They are all taking part in a “Mode VII” emergency landing simulation at Kennedy Space Center. The purpose of the Mode VII is to exercise emergency preparedness personnel, equipment and facilities in rescuing astronauts from a downed orbiter and providing immediate medical attention. This simulation presents an orbiter that has crashed short of the Shuttle Landing Facility in a wooded area 2-1/2 miles south of Runway 33. Emergency crews are responding to the volunteer astronauts who are simulating various injuries inside the crew compartment mock-up. Rescuers must remove the crew, provide triage and transport to hospitals those who need further treatment. Local hospitals are participating in the exercise. Emergency crews are responding to the volunteer astronauts who are simulating various injuries inside the crew compartment mock-up. Rescuers must remove the crew, provide triage and transport to hospitals those who need further treatment. Local hospitals are participating in the exercise.

  9. Integrated, long term, sustainable, cost effective biosolids management at a large Canadian wastewater treatment facility.

    PubMed

    Leblanc, R J; Allain, C J; Laughton, P J; Henry, J G

    2004-01-01

    The Greater Moncton Sewerage Commission's 115,000 m3/d advanced, chemically assisted primary wastewater treatment facility located in New Brunswick, Canada, has developed an integrated, long term, sustainable, cost effective programme for the management and beneficial utilization of biosolids from lime stabilized raw sludge. The paper overviews biosolids production, lime stabilization, conveyance, and odour control followed by an indepth discussion of the wastewater sludge as a resource programme, namely: composting, mine site reclamation, landfill cover, land application for agricultural use, tree farming, sod farm base as a soil enrichment, topsoil manufacturing. The paper also addresses the issues of metals, pathogens, organic compounds, the quality control program along with the regulatory requirements. Biosolids capital and operating costs are presented. Research results on removal of metals from primary sludge using a unique biological process known as BIOSOL as developed by the University of Toronto, Canada to remove metals and destroy pathogens are presented. The paper also discusses an ongoing cooperative research project with the Université de Moncton where various mixtures of plant biosolids are composted with low quality soil. Integration, approach to sustainability and "cumulative effects" as part of the overall biosolids management strategy are also discussed.

  10. 9 CFR 590.548 - Drying, blending, packaging, and heat treatment rooms and facilities.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 9 Animals and Animal Products 2 2011-01-01 2011-01-01 false Drying, blending, packaging, and heat..., blending, packaging, and heat treatment rooms and facilities. (a) General. Processing rooms shall be... vacuum cleaned daily. (c) The heat treatment room shall be of an approved construction and be maintained...

  11. 9 CFR 590.548 - Drying, blending, packaging, and heat treatment rooms and facilities.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 9 Animals and Animal Products 2 2013-01-01 2013-01-01 false Drying, blending, packaging, and heat..., blending, packaging, and heat treatment rooms and facilities. (a) General. Processing rooms shall be... vacuum cleaned daily. (c) The heat treatment room shall be of an approved construction and be maintained...

  12. 9 CFR 590.548 - Drying, blending, packaging, and heat treatment rooms and facilities.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 9 Animals and Animal Products 2 2012-01-01 2012-01-01 false Drying, blending, packaging, and heat..., blending, packaging, and heat treatment rooms and facilities. (a) General. Processing rooms shall be... vacuum cleaned daily. (c) The heat treatment room shall be of an approved construction and be maintained...

  13. 9 CFR 590.548 - Drying, blending, packaging, and heat treatment rooms and facilities.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 9 Animals and Animal Products 2 2014-01-01 2014-01-01 false Drying, blending, packaging, and heat..., blending, packaging, and heat treatment rooms and facilities. (a) General. Processing rooms shall be... vacuum cleaned daily. (c) The heat treatment room shall be of an approved construction and be maintained...

  14. Financing CHP Projects at Wastewater Treatment Facilities with Clean Water State Revolving Funds

    EPA Pesticide Factsheets

    This factsheet provides information about CHP at wastewater treatment facilities, including applications, financial challenges, and financial opportunities, such as the Clean Water State Revolving Fund.

  15. Health Facility Cost of Buruli Ulcer Wound Treatment in Ghana: A Case Study.

    PubMed

    Asare, Kofi Hene; Aikins, Moses

    2014-09-01

    To estimate the wound treatment cost borne by the Buruli Ulcer Treatment Centre of the Amasaman Government Hospital, Ghana. Three different types of data collection approaches were used, namely, 1) observation checklist, 2) in-depth interviews, and 3) expenditure data review. Wound dressing processes were observed. Retrospective health facility cost data of Buruli ulcer (BU) wound treatment for the year 2011 were used. Cost data gathered covered medical and nonmedical items. Cost analyses were carried out to determine the health facility's financial and economic costs. The total annual financial cost was US $121,189.16, of which 99% was recurrent cost. This constitutes about 13% of the expenditure by the Amasaman Government Hospital for the year 2011. The total annual economic cost was US $143,609.22, of which 93% was recurrent cost. The main cost driver for both financial and economic costs was personnel. The annual BU wound treatment costs per capita were US $1615.86 for financial cost and US $1914.79 for economic cost, respectively. The study did not cover household patient costs. The cost of BU wound treatment takes a considerable amount of the hospital's expenditure. This shows the importance of health facility cost as one of the decision-making tools for both resource allocation and mobilization. Hospital management must therefore constantly examine its staffing norms and the associated cost to improve the hospital's resource allocation. Copyright © 2014 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  16. Ground Water Monitoring Requirements for Hazardous Waste Treatment, Storage and Disposal Facilities

    EPA Pesticide Factsheets

    The groundwater monitoring requirements for hazardous waste treatment, storage and disposal facilities (TSDFs) are just one aspect of the Resource Conservation and Recovery Act (RCRA) hazardous waste management strategy for protecting human health and the

  17. Race/ethnicity and geographic access to Medicaid substance use disorder treatment facilities in the United States.

    PubMed

    Cummings, Janet R; Wen, Hefei; Ko, Michelle; Druss, Benjamin G

    2014-02-01

    Although substance use disorders (SUDs) are prevalent and associated with adverse consequences, treatment rates remain low. Unlike physical and mental health problems, treatment for SUDs is predominantly provided in a separate specialty sector and more heavily financed by public sources. Medicaid expansion under the Patient Protection and Affordable Care Act has the potential to increase access to treatment for SUDs but only if an infrastructure exists to serve new enrollees. To examine the availability of outpatient SUD treatment facilities that accept Medicaid across US counties and whether counties with a higher percentage of racial/ethnic minorities are more likely to have gaps in this infrastructure. We used data from the 2009 National Survey of Substance Abuse Treatment Services public use file and the 2011-2012 Area Resource file to examine sociodemographic factors associated with county-level access to SUD treatment facilities that serve Medicaid enrollees. Counties in all 50 states were included. We estimated a probit model with state indicators to adjust for state-level heterogeneity in demographics, politics, and policies. Independent variables assessed county racial/ethnic composition (ie, percentage black and percentage Hispanic), percentage living in poverty, percentage living in a rural area, percentage insured with Medicaid, percentage uninsured, and total population. Dichotomous indicator for counties with at least 1 outpatient SUD treatment facility that accepts Medicaid. Approximately 60% of US counties have at least 1 outpatient SUD facility that accepts Medicaid, although this rate is lower in many Southern and Midwestern states than in other areas of the country. Counties with a higher percentage of black (marginal effect [ME],  -3.1; 95% CI,  -5.2% to -0.9%), rural (-9.2%; -11.1% to -7.4%), and/or uninsured (-9.5%; -13.0% to -5.9%) residents are less likely to have one of these facilities. The potential for increasing access to SUD

  18. Efficiency of U.S. Dialysis Centers: An Updated Examination of Facility Characteristics That Influence Production of Dialysis Treatments

    PubMed Central

    Shreay, Sanatan; Ma, Martin; McCluskey, Jill; Mittelhammer, Ron C; Gitlin, Matthew; Stephens, J Mark

    2014-01-01

    Objective To explore the relative efficiency of dialysis facilities in the United States and identify factors that are associated with efficiency in the production of dialysis treatments. Data Sources/Study Setting Medicare cost report data from 4,343 free-standing dialysis facilities in the United States that offered in-center hemodialysis in 2010. Study Design A cross-sectional, facility-level retrospective database analysis, utilizing data envelopment analysis (DEA) to estimate facility efficiency. Data Collection/Extraction Methods Treatment data and cost and labor inputs of dialysis treatments were obtained from 2010 Medicare Renal Cost Reports. Demographic data were obtained from the 2010 U.S. Census. Principal Findings Only 26.6 percent of facilities were technically efficient. Neither the intensity of market competition nor the profit status of the facility had a significant effect on efficiency. Facilities that were members of large chains were less likely to be efficient. Cost and labor savings due to changes in drug protocols had little effect on overall dialysis center efficiency. Conclusions The majority of free-standing dialysis facilities in the United States were functioning in a technically inefficient manner. As payment systems increasingly employ capitation and bundling provisions, these institutions will need to evaluate their efficiency to remain competitive. PMID:24237043

  19. Actively Controlled Landing Gear for Aircraft Vibration Reduction

    NASA Technical Reports Server (NTRS)

    Horta, Lucas G.; Daugherty, Robert H.; Martinson, Veloria J.

    1999-01-01

    Concepts for long-range air travel are characterized by airframe designs with long, slender, relatively flexible fuselages. One aspect often overlooked is ground induced vibration of these aircraft. This paper presents an analytical and experimental study of reducing ground-induced aircraft vibration loads using actively controlled landing gears. A facility has been developed to test various active landing gear control concepts and their performance. The facility uses a NAVY A6-intruder landing gear fitted with an auxiliary hydraulic supply electronically controlled by servo valves. An analytical model of the gear is presented including modifications to actuate the gear externally and test data is used to validate the model. The control design is described and closed-loop test and analysis comparisons are presented.

  20. Reducing the price of treatment for multidrug-resistant tuberculosis through the Global Drug Facility.

    PubMed

    Lunte, Kaspars; Cordier-Lassalle, Thierry; Keravec, Joel

    2015-04-01

    Many countries have limited experience of securing the best prices for drugs and have little negotiating power. This is particularly true for the complex, lengthy and expensive regimens used to treat multidrug-resistant tuberculosis. The Stop TB Partnership's Global Drug Facility is dedicated to improving worldwide access to antituberculosis medicines and diagnostic techniques that meet international quality standards. The Global Drug Facility is able to secure price reductions through competitive tendering among prequalified drug manufacturers and by consolidating orders to achieve large purchase volumes. Consolidating the market in this way increases the incentives for suppliers of quality-assured medicines. In 2013 the Global Drug Facility reduced the price of the second-line drugs it supplies for multidrug-resistant tuberculosis: the overall cost of the longest and most expensive treatment regimen for a patient decreased by 26% - from 7890 United States dollars (US$) in 2011 to US$ 5822 in 2013. The price of treatment for multidrug-resistant tuberculosis supplied by the Global Drug Facility was reduced by consolidating orders to achieve large purchase volumes, by international, competitive bidding and by the existence of donor-funded medicine stockpiles. The rise in the number of suppliers of internationally quality-assured drugs was also important. The savings achieved from lower drug costs could be used to increase the number of patients on high-quality treatment.

  1. Project C-018H, 242-A Evaporator/PUREX Plant Process Condensate Treatment Facility, functional design criteria. Revision 3

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sullivan, N.

    1995-05-02

    This document provides the Functional Design Criteria (FDC) for Project C-018H, the 242-A Evaporator and Plutonium-Uranium Extraction (PUREX) Plant Condensate Treatment Facility (Also referred to as the 200 Area Effluent Treatment Facility [ETF]). The project will provide the facilities to treat and dispose of the 242-A Evaporator process condensate (PC), the Plutonium-Uranium Extraction (PUREX) Plant process condensate (PDD), and the PUREX Plant ammonia scrubber distillate (ASD).

  2. Verified Centers, Nonverified Centers or Other Facilities: A National Analysis of Burn Patient Treatment Location

    PubMed Central

    Zonies, David; Mack, Christopher; Kramer, Bradley; Rivara, Frederick; Klein, Matthew

    2009-01-01

    Background Although comprehensive burn care requires significant resources, patients may be treated at verified burn centers, non-verified burn centers, or other facilities due to a variety of factors. The purpose of this study was to evaluate the association between patient and injury characteristics and treatment location using a national database. Study Design We performed an analysis of all burn patients admitted to United States hospitals participating in the Healthcare Cost and Utilization Project over 2 years. Univariate and multivariate analyses were performed to identify patient and injury factors associated with the likelihood of treatment at designated burn care facilities. Definitve care facilities were categorized as American Burn Association verified centers, non-verified burn centers, or other facilities. Results Over the two years, 29,971 burn patients were treated in 1,376 hospitals located in 19 participating states. A total of 6,712 (22%) patients were treated at verified centers, with 26% and 52% treated at non-verified or other facilities, respectively. Patients treated at verified centers were younger than those at non-verified or other facilities (33.1 years vs. 33.7 years vs. 41.9 years, p<0.001) and had a higher rate of inhalation injury (3.4% vs. 3.2% vs. 2.2%, p<0.001). Independent factors associated with treatment at verified centers include burns to the head/neck (RR 2.4, CI 2.1-2.7), hand (RR 1.8, CI 1.6-1.9), electrical injury (RR 1.4, CI 1.4, CI 1.2-1.7), and fewer co-morbidities (RR 0.55, CI 0.5-0.6). Conclusions More than two-thirds of significantly burned patients are treated at non-verified burn centers in the U.S. Many patients meeting ABA criteria for transfer to a burn center are being treated at non-burn center facilities. PMID:20193892

  3. 3718-F Alkali Metal Treatment and Storage Facility Closure Plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    Since 1987, Westinghouse Hanford Company has been a major contractor to the U.S. Department of Energy-Richland Operations Office and has served as co-operator of the 3718-F Alkali Metal Treatment and Storage Facility, the waste management unit addressed in this closure plan. The closure plan consists of a Part A Dangerous waste Permit Application and a RCRA Closure Plan. An explanation of the Part A Revision (Revision 1) submitted with this document is provided at the beginning of the Part A section. The closure plan consists of 9 chapters and 5 appendices. The chapters cover: introduction; facility description; process information; wastemore » characteristics; groundwater; closure strategy and performance standards; closure activities; postclosure; and references.« less

  4. Sample Transport for a European Sample Curation Facility

    NASA Astrophysics Data System (ADS)

    Berthoud, L.; Vrublevskis, J. B.; Bennett, A.; Pottage, T.; Bridges, J. C.; Holt, J. M. C.; Dirri, F.; Longobardo, A.; Palomba, E.; Russell, S.; Smith, C.

    2018-04-01

    This work has looked at the recovery of Mars Sample Return capsule once it arrives on Earth. It covers possible landing sites, planetary protection requirements, and transportation from the landing site to a European Sample Curation Facility.

  5. STS-79 landing views

    NASA Image and Video Library

    1996-09-26

    STS079-S-022 (26 Sept. 1996) --- The main landing gear of the space shuttle Atlantis touches down on Runway 15 at the Shuttle Landing Facility (SLF) at the Kennedy Space Center (KSC), bringing an end to the successful ten-day mission. Landing occurred at 8:13:15 a.m. (EDT), Sept. 26, 1996. The touchdown marked the end of 188 days in space for astronaut Shannon W. Lucid, following her in-space exchange with astronaut John E. Blaha, who is now aboard Russia's Mir Space Station. Returning along with Lucid were her STS-79 crew mates - astronauts William F. Readdy, commander; Terrence W. Wilcutt, pilot; and Thomas D. Akers, Jerome (Jay) Apt and Carl E. Walz, mission specialists.

  6. Discovery STS-133 Mission Landing

    NASA Image and Video Library

    2011-03-09

    The runway of the Shuttle Landing Facility (SLF) is marked to show where the wheels stopped for the space shuttle Discovery (STS-133) shortly after it landed, Wednesday, March 9, 2011, at Kennedy Space Center in Cape Canaveral, Fla., completing its 39th and final flight. Since 1984, Discovery flew 39 missions, spent 365 days in space, orbited Earth 5,830 times and traveled 148,221,675 miles. Photo credit: (NASA/Bill Ingalls)

  7. NPDES Permit for Dakota Magic Casino Wastewater Treatment Facility in North Dakota

    EPA Pesticide Factsheets

    Under NPDES permit ND-0030813, the Dakota Nation Gaming Enterprise is authorized to discharge from the wastewater treatment facility in Richland County, North Dakota, to a roadside ditch flowing to an unnamed tributary to the Bois de Sioux.

  8. NPDES Permit for Town of Lodge Grass Wastewater Treatment Facility in Montana

    EPA Pesticide Factsheets

    Under National Pollutant Discharge Elimination System permit number MT0021890, the Town of Lodge Grass is authorized to discharge from from its wastewater treatment facility in Big Horn County to an unnamed slough to the Little Bighorn River.

  9. NPDES Permit for the St. Ignatius-Southside Wastewater Treatment Facility in Montana

    EPA Pesticide Factsheets

    Under NPDES permit MT-0029017, the Salish and Kootenai Housing Authority of the Confederated Salish and Kootenai Tribes is authorized to discharge from its wastewater treatment facility in Lake County, Montana to an unnamed tributary of Sabine Creek.

  10. Land Use Patterns and Fecal Contamination of Coastal Waters in Western Puerto Rico

    NASA Technical Reports Server (NTRS)

    Norat, Jose

    1994-01-01

    The Department of Environmental Health of the Graduate School of Public Health of the Medical Sciences Campus, University of Puerto Rico (UPR-RCM) conducted this research project on how different patterns of land use affect the microbiological quality of rivers flowing into Mayaguez Bay in Western Puerto Rico. Coastal shellfish growing areas, stream and ocean bathing beaches, and pristine marine sites in the Bay are affected by the discharge of the three study rivers. Satellite imagery was used to study watershed land uses which serve as point and nonpoint sources of pathogens affecting stream and coastal water users. The study rivers drain watersheds of different size and type of human activity (including different human waste treatment and disposal facilities). Land use and land cover in the study watersheds were interpreted, classified and mapped using remotely sensed images from NASA's Landsat Thematic Mapper (TM). This study found there is a significant relationship between watershed land cover and microbiological water quality of rivers flowing into Mayaguez Bay in Western Puerto Rico. Land covers in the Guanajibo, Anasco, and Yaguez watersheds were classified into forested areas, pastures, agricultural zones and urban areas so as to determine relative contributions to fecal water contamination. The land cover classification was made processing TM images with IDRISI and ERDAS software.

  11. Implementing Trauma-Informed Treatment for Youth in a Residential Facility: First-Year Outcomes

    ERIC Educational Resources Information Center

    Greenwald, Ricky; Siradas, Lynn; Schmitt, Thomas A.; Reslan, Summar; Fierle, Julia; Sande, Brad

    2012-01-01

    Training in the Fairy Tale model of trauma-informed treatment was provided to clinical and direct care staff working with 53 youth in a residential treatment facility. Compared to the year prior to training, in the year of the training the average improvement in presenting problems was increased by 34%, time to discharge was reduced by 39%, and…

  12. 76 FR 52346 - Public Land Order No. 7760; Extension of Public Land Order No. 6839; Alaska; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-22

    ... Survey facility encumbers 45 acres for the Barrow Magnetic Observatory.'' is hereby corrected to read... Magnetic Observatory.'' Robert L. Lloyd, Supervisor, Lands, Realty and Title Transfer Program, Division of...

  13. Aquatic Plants and Wastewater Treatment (an Overview)

    NASA Technical Reports Server (NTRS)

    Wolverton, B. C.

    1986-01-01

    The technology for using water hyacinth to upgrade domestic sewage effluent from lagoons and other wastewater treatment facilities to secondary and advanced secondary standards has been sufficiently developed to be used where the climate is warm year round. The technology of using emergent plants such as bulrush combined with duckweed is also sufficiently developed to make this a viable wastewater treatment alternative. This system is suited for both temperate and semi-tropical areas found throughout most of the U.S. The newest technology in artificial marsh wastewater treatment involves the use of emergent plant roots in conjunction with high surface area rock filters. Smaller land areas are required for these systems because of the increased concentration of microorganisms associated with the rock and plant root surfaces. Approximately 75 percent less land area is required for the plant-rock system than is required for a strict artificial wetland to achieve the same level of treatment.

  14. EPA Facility Registry Service (FRS): Facility Interests Dataset Download

    EPA Pesticide Factsheets

    This downloadable data package consists of location and facility identification information from EPA's Facility Registry Service (FRS) for all sites that are available in the FRS individual feature layers. The layers comprise the FRS major program databases, including:Assessment Cleanup and Redevelopment Exchange System (ACRES) : brownfields sites ; Air Facility System (AFS) : stationary sources of air pollution ; Air Quality System (AQS) : ambient air pollution data from monitoring stations; Bureau of Indian Affairs (BIA) : schools data on Indian land; Base Realignment and Closure (BRAC) facilities; Clean Air Markets Division Business System (CAMDBS) : market-based air pollution control programs; Comprehensive Environmental Response, Compensation, and Liability Information System (CERCLIS) : hazardous waste sites; Integrated Compliance Information System (ICIS) : integrated enforcement and compliance information; National Compliance Database (NCDB) : Federal Insecticide, Fungicide, and Rodenticide Act (FIFRA) and the Toxic Substances Control Act (TSCA); National Pollutant Discharge Elimination System (NPDES) module of ICIS : NPDES surface water permits; Radiation Information Database (RADINFO) : radiation and radioactivity facilities; RACT/BACT/LAER Clearinghouse (RBLC) : best available air pollution technology requirements; Resource Conservation and Recovery Act Information System (RCRAInfo) : tracks generators, transporters, treaters, storers, and disposers

  15. Outdoors America: recreational opportunities on public lands

    USGS Publications Warehouse

    ,

    1998-01-01

    This Federal Recreation Lands map is a consolidated guide to public lands offering outdoor recreation opportunities. Some areas have more recreation potential than others, and types of recreation available may vary from place to place. Many areas include private land not open to the public. Care should be taken to respect the rights of private property owners. For information regarding specific activities, services, facilities, hours and seasons of operation, entrance and other user fees, and accessibility, contact the appropriate agency office.

  16. 43 CFR 3271.13 - How do I obtain approval to build pipelines and facilities connecting the well field to...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 43 Public Lands: Interior 2 2011-10-01 2011-10-01 false How do I obtain approval to build pipelines and facilities connecting the well field to utilization facilities not located on Federal lands leased for geothermal resources? 3271.13 Section 3271.13 Public Lands: Interior Regulations Relating to Public Lands (Continued) BUREAU OF LAND...

  17. 43 CFR 3271.13 - How do I obtain approval to build pipelines and facilities connecting the well field to...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 43 Public Lands: Interior 2 2013-10-01 2013-10-01 false How do I obtain approval to build pipelines and facilities connecting the well field to utilization facilities not located on Federal lands leased for geothermal resources? 3271.13 Section 3271.13 Public Lands: Interior Regulations Relating to Public Lands (Continued) BUREAU OF LAND...

  18. 43 CFR 3271.13 - How do I obtain approval to build pipelines and facilities connecting the well field to...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 43 Public Lands: Interior 2 2014-10-01 2014-10-01 false How do I obtain approval to build pipelines and facilities connecting the well field to utilization facilities not located on Federal lands leased for geothermal resources? 3271.13 Section 3271.13 Public Lands: Interior Regulations Relating to Public Lands (Continued) BUREAU OF LAND...

  19. 43 CFR 3271.13 - How do I obtain approval to build pipelines and facilities connecting the well field to...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 43 Public Lands: Interior 2 2012-10-01 2012-10-01 false How do I obtain approval to build pipelines and facilities connecting the well field to utilization facilities not located on Federal lands leased for geothermal resources? 3271.13 Section 3271.13 Public Lands: Interior Regulations Relating to Public Lands (Continued) BUREAU OF LAND...

  20. 10 CFR 61.50 - Disposal site suitability requirements for land disposal.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 2 2013-01-01 2013-01-01 false Disposal site suitability requirements for land disposal. 61.50 Section 61.50 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) LICENSING REQUIREMENTS FOR LAND DISPOSAL OF RADIOACTIVE WASTE Technical Requirements for Land Disposal Facilities § 61.50 Disposal site...

  1. 10 CFR 61.50 - Disposal site suitability requirements for land disposal.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 2 2012-01-01 2012-01-01 false Disposal site suitability requirements for land disposal. 61.50 Section 61.50 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) LICENSING REQUIREMENTS FOR LAND DISPOSAL OF RADIOACTIVE WASTE Technical Requirements for Land Disposal Facilities § 61.50 Disposal site...

  2. 10 CFR 61.50 - Disposal site suitability requirements for land disposal.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 2 2014-01-01 2014-01-01 false Disposal site suitability requirements for land disposal. 61.50 Section 61.50 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) LICENSING REQUIREMENTS FOR LAND DISPOSAL OF RADIOACTIVE WASTE Technical Requirements for Land Disposal Facilities § 61.50 Disposal site...

  3. 10 CFR 61.50 - Disposal site suitability requirements for land disposal.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 2 2011-01-01 2011-01-01 false Disposal site suitability requirements for land disposal. 61.50 Section 61.50 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) LICENSING REQUIREMENTS FOR LAND DISPOSAL OF RADIOACTIVE WASTE Technical Requirements for Land Disposal Facilities § 61.50 Disposal site...

  4. 10 CFR 61.50 - Disposal site suitability requirements for land disposal.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 2 2010-01-01 2010-01-01 false Disposal site suitability requirements for land disposal. 61.50 Section 61.50 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) LICENSING REQUIREMENTS FOR LAND DISPOSAL OF RADIOACTIVE WASTE Technical Requirements for Land Disposal Facilities § 61.50 Disposal site...

  5. Modeling fuel treatment costs on Forest Service Lands in the Western United States

    Treesearch

    David Calkin; Krista Gebert

    2006-01-01

    Years of successful fire suppression have led to high fuel loads on the nation's forests, and steps are being taken by the nation's land management agencies to reduce these fuel loads. However, to achieve desired outcomes in a fiscally responsible manner, the cost and effectiveness in reducing losses due to wildland fire of different fuel treatments in...

  6. 77 FR 58470 - Irradiation Treatment; Location of Facilities in the Southern United States; Technical Amendment

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-21

    .... APHIS-2009-0100] RIN 0579-AD35 Irradiation Treatment; Location of Facilities in the Southern United... things, allow for irradiation treatment of mangoes from India upon arrival in the mainland United States... 20, 2012, we amended the regulations in Sec. 319.56-46 to allow for irradiation treatment of mangoes...

  7. EPA Facility Registry Service (FRS): Facility Interests Dataset

    EPA Pesticide Factsheets

    This web feature service consists of location and facility identification information from EPA's Facility Registry Service (FRS) for all sites that are available in the FRS individual feature layers. The layers comprise the FRS major program databases, including:Assessment Cleanup and Redevelopment Exchange System (ACRES) : brownfields sites ; Air Facility System (AFS) : stationary sources of air pollution ; Air Quality System (AQS) : ambient air pollution data from monitoring stations; Bureau of Indian Affairs (BIA) : schools data on Indian land; Base Realignment and Closure (BRAC) facilities; Clean Air Markets Division Business System (CAMDBS) : market-based air pollution control programs; Comprehensive Environmental Response, Compensation, and Liability Information System (CERCLIS) : hazardous waste sites; Integrated Compliance Information System (ICIS) : integrated enforcement and compliance information; National Compliance Database (NCDB) : Federal Insecticide, Fungicide, and Rodenticide Act (FIFRA) and the Toxic Substances Control Act (TSCA); National Pollutant Discharge Elimination System (NPDES) module of ICIS : NPDES surface water permits; Radiation Information Database (RADINFO) : radiation and radioactivity facilities; RACT/BACT/LAER Clearinghouse (RBLC) : best available air pollution technology requirements; Resource Conservation and Recovery Act Information System (RCRAInfo) : tracks generators, transporters, treaters, storers, and disposers of haz

  8. Health worker perspectives on the possible use of intramuscular artesunate for the treatment of severe malaria at lower-level health facilities in settings with poor access to referral facilities in Nigeria: a qualitative study.

    PubMed

    Adesoro, Olatunde; Shumba, Constance; Kpamor, John; Achan, Jane; Kivumbi, Harriet; Dada, John; Maxwell, Kolawole; Tibenderana, James; Marasciulo, Madeline; Hamade, Prudence; Oresanya, Olusola; Nankabirwa, Joanita; Baba, Ebenezer

    2016-10-12

    Innovative strategies are needed to reduce malaria mortality in high burden countries like Nigeria. Given that one of the important reasons for this high malaria mortality is delay in receiving effective treatment, improved access to such treatment is critical. Intramuscular artesunate could be used at lower-level facilities given its proven efficacy, ease of use and excellent safety profile. The objective of this study was therefore to explore health workers' perspectives on the possible use of intramuscular artesunate as definitive treatment for severe malaria at lower-level facilities, especially when access to referral facilities is challenging. The study was to provide insight as a formative step into the conduct of future experimental studies to ascertain the feasibility of the use of intramuscular artesunate for definitive treatment of severe malaria in lower level facilities where access to referral care is limited. This qualitative study was done across three southern States in Nigeria (Oyo, Cross River and Enugu). Key informant interviews were conducted over a period of three months between October and December 2014 among 90 purposively selected health workers with different roles in malaria case management from primary care to policy level. A thematic content analysis was used to analyse data. Overall, most of health workers and other key informant groups thought that the use of intramuscular artesunate for definitive treatment of severe malaria at lower-level facilities was possible. They however reported human resource and infrastructure constraints as factors affecting the feasibility of intramuscular artesunate use as definitive treatment for severe malaria in lower-level facilities.. Specifically identified barriers included limited numbers of skilled health workers available to manage potential complications of severe malaria and poorly equipped facilities for supportive treatment. Intramuscular artesunate was considered easy to administer and the

  9. Effectiveness of aquatic versus land physiotherapy in the treatment of peripheral neuropathies: a randomized controlled trial.

    PubMed

    Zivi, Ilaria; Maffia, Sara; Ferrari, Vanessa; Zarucchi, Alessio; Molatore, Katia; Maestri, Roberto; Frazzitta, Giuseppe

    2018-05-01

    To compare the effects on gait and balance of aquatic physiotherapy versus on-land training, in the context of an inpatient rehabilitation treatment tailored for peripheral neuropathies. Parallel-group, single-center, single-blind randomized controlled trial. Consecutive patients affected by peripheral neuropathy admitted in our Neuro-Rehabilitation Unit. Patients received a four-week rehabilitation program composed by daily sessions of conventional physiotherapy and three sessions/week of specific treatment (aquatic vs. on-land). Primary outcome measures were Berg Balance Scale and Dynamic Gait Index. Secondary outcome measures were Neuropathic Pain Scale, Overall Neuropathy Limitations Scale, Functional Independence Measure, Functional Ambulation Classification, Conley Scale and Medical Research Council Scale score for the strength of hip and ankle flexor and extensor muscles. For each scale, we calculated the difference between the scores at discharge and admission and compared it between the two groups. Forty patients were enrolled: 21 in the water-based rehabilitation group and 19 in the land-based one. Patients were similar between groups. When comparing the groups, we found that "in-water" patients had a significant better improvement in the Dynamic Gait Index score (6.00 (4.00, 7.25) vs. 4.00 (1.25, 6.00), P = 0.0433). On the opposite, the "on-land" group showed a better improvement of the Functional Ambulation Classification score (1.0 (0.75, 1.0) vs. 1.0 (1.0, 2.0), P = 0.0386). Aquatic physiotherapy showed an effect comparable to the land-based rehabilitation on gait and balance dysfunctions of neuropathic patients.

  10. NPDES Permit for Rosebud Casino and Hotel Wastewater Treatment Facility in South Dakota

    EPA Pesticide Factsheets

    Under NPDES permit SD-0034584, Rosebud Casino and Hotel, South Dakota, is authorized to discharge from its wastewater treatment facility in Todd County, South Dakota to an unnamed drainageway(s) tributary to Rock Creek.

  11. Topics in landing gear dynamics research at NASA Langley

    NASA Technical Reports Server (NTRS)

    Mccomb, H. G., Jr.; Tanner, J. A.

    1986-01-01

    Four topics in landing gear dynamics are discussed. Three of these topics are subjects of recent research: tilt steering phenomenon, water spray ingestion on flooded runways, and actively controlled landing gear. The fourth topic is a description of a major facility recently enhanced in capability.

  12. Treatment of depression in low-level residential care facilities for the elderly.

    PubMed

    George, Kuruvilla; Davison, Tanya E; McCabe, Marita; Mellor, David; Moore, Kathleen

    2007-12-01

    The rate of recognition and treatment of depressed older people in nursing homes is low. Data from the low-level residential care population have not been reported. This study aimed to collect information about the treatment of depression among older persons living in low-level residential care (hostels). The participants comprised 300 elderly residents from ten low-level residential care facilities from various suburbs in metropolitan Melbourne. The participants were interviewed by a trained clinical psychologist to determine the presence or absence of major or minor depressive disorder using the Structured Clinical Interview for DSM-IV Axis I Disorder (SCID-I). Each participant was also administered the Standardized Mini-mental State Examination (SMMSE) to determine level of cognitive function. The clinical psychologist then reviewed all cases in consultation with a geropsychiatrist experienced in the diagnosis of depression among older people, prior to assigning a diagnosis of depression. An important finding in this study was the low treatment for currently depressed residents, with less than half of those in the sample who were depressed receiving treatment. However, 61 of the 96 residents out of the sample of 300 who were on antidepressants were not currently depressed. There is an under recognition and under treatment of currently depressed older people in low-level residential care facilities (hostels) just as has been reported in studies in nursing homes. However, there are high numbers receiving antidepressants who are not currently depressed.

  13. NPDES Draft Permit for MHA Interpretive Center Wastewater Treatment Facility in North Dakota

    EPA Pesticide Factsheets

    Under draft NPDES permit ND0031160, the Mandan, Hidatsa, and Arikara (MHA) Nation Public Works is authorized to discharge from its MHA Interpretive Center wastewater treatment facility to Missouri River as set forth in the permit.

  14. NPDES Draft Permit for Southern Ute Indian Tribe Wastewater Treatment Facility in Colorado

    EPA Pesticide Factsheets

    Under NPDES draft permit number CO-0022853, the Southern Ute Indian Tribe is authorized to discharge from its wastewater treatment facility in La Plata County, Colorado,to Rock Creek, a tributary of the Los Pinos River.

  15. NPDES Permit for City of Eagle Butte Wastewater Treatment Facility in South Dakota

    EPA Pesticide Factsheets

    Under NPDES permit SD-0020192, the City of Eagle Butte, South Dakota, is authorized to discharge from its wastewater treatment facility within the Cheyenne River Sioux Reservation in Dewey County, South Dakota, to Green Grass Creek.

  16. Land Treatment. Instructor Guide. Working for Clean Water: An Information Program for Advisory Committees

    ERIC Educational Resources Information Center

    Pennsylvania State Univ., Middletown. Inst. of State and Regional Affairs.

    Presented is an instructor's manual for a learning session centered on the methodology and feasibility of land treatment of municipal wastewater. A supplementary slide-tape program is available. These materials are components of the Working for Clean Water Project, which is intended to educate advisory groups who are interested in improving…

  17. STS-83 landing views

    NASA Image and Video Library

    2016-08-16

    STS083-S-009 (8 April 1997) --- The Space Shuttle Columbia nears touchdown on the Shuttle Landing Facility (SLF) runway at the Kennedy Space Center (KSC), after completing almost four days of a scheduled 16-day mission in Earth-orbit. A problem with one of three fuel cells led to an early landing for the seven-member Microgravity Science Laboratory 1 (MSL-1) crew. Touchdown occurred at 1:33:11 p.m. (EDT), April 8, 1997. Onboard Columbia were James D. Halsell, Jr., Susan L. Still, Janice E. Voss, Donald A. Thomas, Michael L. Gernhardt, Roger K. Crouch and Gregory T. Linteris.

  18. Facility S 372, replacement dolphins and ramp from upper deck ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Facility S 372, replacement dolphins and ramp from upper deck of ferry boat (YFB 87). - U.S. Naval Base, Pearl Harbor, Ferry Landing Type, Halawa Landing on Ford Island, Pearl City, Honolulu County, HI

  19. EPA Facility Registry Service (FRS): Facility Interests Dataset - Intranet Download

    EPA Pesticide Factsheets

    This downloadable data package consists of location and facility identification information from EPA's Facility Registry Service (FRS) for all sites that are available in the FRS individual feature layers. The layers comprise the FRS major program databases, including:Assessment Cleanup and Redevelopment Exchange System (ACRES) : brownfields sites ; Air Facility System (AFS) : stationary sources of air pollution ; Air Quality System (AQS) : ambient air pollution data from monitoring stations; Bureau of Indian Affairs (BIA) : schools data on Indian land; Base Realignment and Closure (BRAC) facilities; Clean Air Markets Division Business System (CAMDBS) : market-based air pollution control programs; Comprehensive Environmental Response, Compensation, and Liability Information System (CERCLIS) : hazardous waste sites; Integrated Compliance Information System (ICIS) : integrated enforcement and compliance information; National Compliance Database (NCDB) : Federal Insecticide, Fungicide, and Rodenticide Act (FIFRA) and the Toxic Substances Control Act (TSCA); National Pollutant Discharge Elimination System (NPDES) module of ICIS : NPDES surface water permits; Radiation Information Database (RADINFO) : radiation and radioactivity facilities; RACT/BACT/LAER Clearinghouse (RBLC) : best available air pollution technology requirements; Resource Conservation and Recovery Act Information System (RCRAInfo) : tracks generators, transporters, treaters, storers, and disposers

  20. Land Use and the Legislatures: The Politics of State Innovation. Land Use Series.

    ERIC Educational Resources Information Center

    Rosenbaum, Nelson

    This study analyzes and predicts the spread of three different types of land use legislation: mandatory local growth management, major facility siting, and critical areas protection. Chapter 2 focuses on innovative statutes that provide a new or expanded role for state agencies in supervising local control of development. The three statutes…

  1. Remedy Selection and Land Use at Federal Facilities

    EPA Pesticide Factsheets

    Analysis of approximately 98 percent of the interim and final source control Records of Decision signed at Federal Facilities on the NPL from the beginning of Superfund through August 1995. PB96-963309. EPA/540/R-96/020. August 1996

  2. LPT. Shield test facility (TAN646). Floor plan for water treatment ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    LPT. Shield test facility (TAN-646). Floor plan for water treatment room on west facade, tank and filter locations in basement along service tunnel and in coupling station. Ralph M. Parsons 1229-17 ANP/GE-6-646-P-2. April 1957. INEEL Index code no. 037-0645/0646-51-693-107387 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  3. NPDES Permit for U.S. Air Force Academy Wastewater Treatment Facility in Colorado

    EPA Pesticide Factsheets

    Under NPDES permit CO-0020974, the U.S. Air Force Academy is authorized to discharge from its wastewater treatment facility in El Paso County, Colorado, to Non-Potable Reservoir No. 1 on Lehman Run and to Monument Creek.

  4. Lessons Learned from the 200 West Pump and Treatment Facility Construction Project at the US DOE Hanford Site - A Leadership for Energy and Environmental Design (LEED) Gold-Certified Facility - 13113

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dorr, Kent A.; Freeman-Pollard, Jhivaun R.; Ostrom, Michael J.

    CH2M Hill Plateau Remediation Company (CHPRC) designed, constructed, commissioned, and began operation of the largest groundwater pump and treatment facility in the U.S. Department of Energy's (DOE) nationwide complex. This one-of-a-kind groundwater pump and treatment facility, located at the Hanford Nuclear Reservation Site (Hanford Site) in Washington State, was built to an accelerated schedule with American Recovery and Reinvestment Act (ARRA) funds. There were many contractual, technical, configuration management, quality, safety, and Leadership in Energy and Environmental Design (LEED) challenges associated with the design, procurement, construction, and commissioning of this $95 million, 52,000 ft groundwater pump and treatment facility tomore » meet DOE's mission objective of treating contaminated groundwater at the Hanford Site with a new facility by June 28, 2012. The project team's successful integration of the project's core values and green energy technology throughout design, procurement, construction, and start-up of this complex, first-of-its-kind Bio Process facility resulted in successful achievement of DOE's mission objective, as well as attainment of LEED GOLD certification (Figure 1), which makes this Bio Process facility the first non-administrative building in the DOE Office of Environmental Management complex to earn such an award. (authors)« less

  5. Evaluating the Treatment Costs for Uncomplicated Malaria at a Public Healthcare Facility in Nigeria and the Implications.

    PubMed

    Ezenduka, Charles C; Falleiros, Daniel Resende; Godman, Brian B

    2017-09-01

    Accurate information on the facility costs of treatment is essential to enhance decision making and funding for malaria control. The objective of this study was to estimate the costs of providing treatment for uncomplicated malaria through a public health facility in Nigeria. Hospital costs were estimated from a provider perspective, applying a standard costing procedure. Capital and recurrent expenditures were estimated using an ingredient approach combined with step-down methodology. Costs attributable to malaria treatment were calculated based on the proportion of malaria cases to total outpatient visits. The costs were calculated in local currency [Naira (N)] and converted to US dollars at the 2013 exchange rate. Total annual costs of N28.723 million (US$182,953.65) were spent by the facility on the treatment of uncomplicated malaria, at a rate of US$31.49 per case, representing approximately 25% of the hospital's total expenditure in the study year. Personnel accounted for over 82.5% of total expenditure, followed by antimalarial medicines at 6.6%. More than 45% of outpatients visits were for uncomplicated malaria. Changes in personnel costs, drug prices and malaria prevalence significantly impacted on the study results, indicating the need for improved efficiency in the use of hospital resources. Malaria treatment currently consumes a considerable amount of resources in the facility, driven mainly by personnel cost and a high proportion of malaria cases. There is scope for enhanced efficiency to prevent waste and reduce costs to the provider and ultimately the consumer.

  6. Lunar Landing Walking Simulator

    NASA Image and Video Library

    1965-09-03

    Lunar Landing Walking Simulator: Researchers at Langley study the ability of astronauts to walk, run and perform other tasks required during lunar exploration. The Reduced Gravity Simulator gave researchers the opportunity to look at the effects of one-sixth normal gravity on self-locomotion. Several Apollo astronauts practiced lunar waling at the facility.

  7. Beyond land application: Emerging technologies for the treatment and reuse of anaerobically digested agricultural and food waste.

    PubMed

    Sheets, Johnathon P; Yang, Liangcheng; Ge, Xumeng; Wang, Zhiwu; Li, Yebo

    2015-10-01

    Effective treatment and reuse of the massive quantities of agricultural and food wastes generated daily has the potential to improve the sustainability of food production systems. Anaerobic digestion (AD) is used throughout the world as a waste treatment process to convert organic waste into two main products: biogas and nutrient-rich digestate, called AD effluent. Biogas can be used as a source of renewable energy or transportation fuels, while AD effluent is traditionally applied to land as a soil amendment. However, there are economic and environmental concerns that limit widespread land application, which may lead to underutilization of AD for the treatment of agricultural and food wastes. To combat these constraints, existing and novel methods have emerged to treat or reuse AD effluent. The objective of this review is to analyze several emerging methods used for efficient treatment and reuse of AD effluent. Overall, the application of emerging technologies is limited by AD effluent composition, especially the total solid content. Some technologies, such as composting, use the solid fraction of AD effluent, while most other technologies, such as algae culture and struvite crystallization, use the liquid fraction. Therefore, dewatering of AD effluent, reuse of the liquid and solid fractions, and land application could all be combined to sustainably manage the large quantities of AD effluent produced. Issues such as pathogen regrowth and prevalence of emerging organic micro-pollutants are also discussed. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Landing impact studies of a 0.3-scale model air cushion landing system for a Navy fighter airplane

    NASA Technical Reports Server (NTRS)

    Leland, T. J. W.; Thompson, W. C.

    1975-01-01

    An experimental study was conducted in order to determine the landing-impact behavior of a 0.3-scale, dynamically (but not physically) similar model of a high-density Navy fighter equipped with an air cushion landing system. The model was tested over a range of landing contact attitudes at high forward speeds and sink rates on a specialized test fixture at the Langley aircraft landing loads and traction facility. The investigation indicated that vertical acceleration at landing impact was highly dependent on the pitch angle at ground contact, the higher acceleration of approximately 5g occurring near zero body-pitch attitude. A limited number of low-speed taxi tests were made in order to determine model stability characteristics. The model was found to have good pitch-damping characteristics but stability in roll was marginal.

  9. EPA Facility Registry Service (FRS): Facility Interests Dataset - Intranet

    EPA Pesticide Factsheets

    This web feature service consists of location and facility identification information from EPA's Facility Registry Service (FRS) for all sites that are available in the FRS individual feature layers. The layers comprise the FRS major program databases, including:Assessment Cleanup and Redevelopment Exchange System (ACRES) : brownfields sites ; Air Facility System (AFS) : stationary sources of air pollution ; Air Quality System (AQS) : ambient air pollution data from monitoring stations; Bureau of Indian Affairs (BIA) : schools data on Indian land; Base Realignment and Closure (BRAC) facilities; Clean Air Markets Division Business System (CAMDBS) : market-based air pollution control programs; Comprehensive Environmental Response, Compensation, and Liability Information System (CERCLIS) : hazardous waste sites; Integrated Compliance Information System (ICIS) : integrated enforcement and compliance information; National Compliance Database (NCDB) : Federal Insecticide, Fungicide, and Rodenticide Act (FIFRA) and the Toxic Substances Control Act (TSCA); National Pollutant Discharge Elimination System (NPDES) module of ICIS : NPDES surface water permits; Radiation Information Database (RADINFO) : radiation and radioactivity facilities; RACT/BACT/LAER Clearinghouse (RBLC) : best available air pollution technology requirements; Resource Conservation and Recovery Act Information System (RCRAInfo) : tracks generators, transporters, treaters, storers, and disposers of haz

  10. 10 CFR 61.32 - Facility information and verification.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 2 2012-01-01 2012-01-01 false Facility information and verification. 61.32 Section 61.32 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) LICENSING REQUIREMENTS FOR LAND DISPOSAL OF RADIOACTIVE WASTE Licenses Us/iaea Safeguards Agreement § 61.32 Facility information and verification. (a) In...

  11. 10 CFR 61.32 - Facility information and verification.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 2 2014-01-01 2014-01-01 false Facility information and verification. 61.32 Section 61.32 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) LICENSING REQUIREMENTS FOR LAND DISPOSAL OF RADIOACTIVE WASTE Licenses Us/iaea Safeguards Agreement § 61.32 Facility information and verification. (a) In...

  12. 10 CFR 61.32 - Facility information and verification.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 2 2011-01-01 2011-01-01 false Facility information and verification. 61.32 Section 61.32 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) LICENSING REQUIREMENTS FOR LAND DISPOSAL OF RADIOACTIVE WASTE Licenses Us/iaea Safeguards Agreement § 61.32 Facility information and verification. (a) In...

  13. NPDES Draft Permit for Dakota Magic Casino Wastewater Treatment Facility in North Dakota

    EPA Pesticide Factsheets

    Under NPDES draft permit ND0030813, the Dakota Magic Hotel and Casino WWTF is authorized to discharge, in accordance with the requirements as contained in the provisions of this Permit, from its wastewater treatment facility to the Bois de Sioux.

  14. The effect of sensor spacing on wind measurements at the Shuttle Landing Facility

    NASA Technical Reports Server (NTRS)

    Merceret, Francis J.

    1995-01-01

    This document presents results of a field study of the effect of sensor spacing on the validity of wind measurements at the Space Shuttle landing Facility (SLF). Standard measurements are made at one second intervals from 30 foot (9.1m) towers located 500 feet (152m) from the SLF centerline. The centerline winds are not exactly the same as those measured by the towers. This study quantifies the differences as a function of statistics of the observed winds and distance between the measurements and points of interest. The field program used logarithmically spaced portable wind towers to measure wind speed and direction over a range of conditions. Correlations, spectra, moments, and structure functions were computed. A universal normalization for structure functions was devised. The normalized structure functions increase as the 2/3 power of separation distance until an asymptotic value is approached. This occurs at spacings of several hundred feet (about 100m). At larger spacings, the structure functions are bounded by the asymptote. This enables quantitative estimates of the expected differences between the winds at the measurement point and the points of interest to be made from the measured wind statistics. A procedure is provided for making these estimates.

  15. 47 CFR 87.307 - Cooperative use of facilities.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... SERVICES AVIATION SERVICES Flight Test Stations § 87.307 Cooperative use of facilities. (a) The Commission will license only one flight test land station per airport, except as provided in paragraph (d) of this section. (b) Flight test land stations located at an airport are required to provide service without...

  16. US Environmental rotection Agency's strategy for ground-water-quality monitoring at hazardous-waste land-disposal facilities located in karst terranes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Field, M.S.

    1988-11-01

    Ground-water monitoring of hazardous-waste land-disposal units by a network of wells is ineffective when located in karstic terranes. The U.S. Environmental Protection Agency (EPA) is currently proposing to modify its current ground-water-quality monitoring requirement of one upgradient well and three downgradient wells for disposal units located in karstic terranes. The convergent nature of subsurface flow to cave streams in karstic terranes requires that effective monitoring wells intercept the cave streams. Wells located around a hazardous-waste disposal unit, but not in the specific cave stream draining the site, are only providing irrelevant data and a false sense of security because themore » water samples from such wells are not necessarily from the hazardous-waste disposal unit. A case study is provided in this paper. EPA is drafting a guidance document that will allow monitoring by wells, only if the up- and down-gradient wells can be demonstrated to be hydraulically connected by means of dye-trace studies. If not, then the monitoring of springs shown to be hydraulically connected to the facility by dye-tracing studies would be required. Monitoring for sinkhole development will also be required to provide advance warning of sinkhole collapse. The investigation and determination of the probability of sinkhole collapse is given special treatment.« less

  17. Optimal capacity design of LID facility for conserving natural water cycle and its sensitivity analysis

    NASA Astrophysics Data System (ADS)

    Lee, O.; Choi, J.; Lee, J.; Kim, S.

    2017-12-01

    Since the 20th century, urbanization has resulted in increased impermeable land surface and reduced infiltration capacity in catchment scale. Especially, when agriculture area or forest area would be developed into urban area, it can cause more runoff in the same climate condition. Such urbanization causes problems such as changes in hydrological cycle and ecosystem disturbance. Various methods have been proposed worldwide to reduce the impact of such urbanization. Among the various strategies, the low-impact development is a development strategy that aims to return to pre-development state by minimizing the change of the hydrological cycle due to urbanization. In this strategy, the infiltration and/or surface storage of stormwater runoff can be increased through the installation of various facilities. In this study, a facility capacity design strategy is proposed to return into the natural water cycle through the installation of various LID facilities. This is accomplished by determining the optimal LID facility design capacity through which flow duration curves remain the same before and after urban development. For this purpose, EPA-SWMM is constructed with a part of Busan Metropolitan City Noksan Industrial Complex as a virtual processing area. Under the various land-use scenarios, the optimum design capacity of various LID facilities capable of retaining the flow duration curve before and after development is determined. In addition, the sensitivity of the optimal design capacity of LID facilities is analyzed according to the design specifications of various LID facilities, the local rainfall characteristics, and the size of the treatment area. Acknowledgement This research was supported by a grant (2016000200002) from Public Welfare Technology Development Program funded by Ministry of Environment of Korean government.

  18. STS-70 Crew in front of Discovery post landing

    NASA Technical Reports Server (NTRS)

    1995-01-01

    STS-70 crew members give a 'thumbs up' to press representatives and others waiting to greet them on Runway 33 of KSC's Shuttle Landing Facility after the conclusion of their successful flight on the Space Shuttle Discovery. From left, are Commander Terence 'Tom' Henricks, Mission Specialists Mary Ellen Weber, Nancy Jane Currie and Donald A. Thomas, and Pilot Kevin R. Kregel. Discovery landed on orbit 143. Main gear touchdown was unofficially listed at 8:02 a.m. EDT on July 22, 1995. Both opportunities for a KSC touchdown on the scheduled landing date, July 21, were waived off because of fog and low visibility conditions at the Shuttle Landing Facility. The first opportunity on July 22 at KSC also was waived off. STS-70 was the 24th landing at KSC and the 70th Space Shuttle mission. During the eight-day, 22-hour flight, the crew deployed a Tracking and Data Relay Satellite-G (TDRS-G) and performed many experiments. STS-70 also was the maiden flight of the new Block I orbiter main engine, which flew in the number one position. The other two engines were of the existing Phase II design.

  19. 78 FR 53184 - Land Release for Penn Yan Airport

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-28

    ... easement of 0.069 +/-acres for ingress/egress to a boat storage and maintenance facility to be constructed.../egress to the Land and Sea Properties boat storage and maintenance facility from the Penn Yan Airport access road. Documents reflecting the Sponsor's request are available, by appointment only, for...

  20. Improving the Quality of Services in Residential Treatment Facilities: A Strength-Based Consultative Review Process

    ERIC Educational Resources Information Center

    Pavkov, Thomas W.; Lourie, Ira S.; Hug, Richard W.; Negash, Sesen

    2010-01-01

    This descriptive case study reports on the positive impact of a consultative review methodology used to conduct quality assurance reviews as part of the Residential Treatment Center Evaluation Project. The study details improvement in the quality of services provided to youth in unmonitored residential treatment facilities. Improvements were…

  1. Comprehensive facilities plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1997-09-01

    The Ernest Orlando Lawrence Berkeley National Laboratory`s Comprehensive Facilities Plan (CFP) document provides analysis and policy guidance for the effective use and orderly future development of land and capital assets at the Berkeley Lab site. The CFP directly supports Berkeley Lab`s role as a multiprogram national laboratory operated by the University of California (UC) for the Department of Energy (DOE). The CFP is revised annually on Berkeley Lab`s Facilities Planning Website. Major revisions are consistent with DOE policy and review guidance. Facilities planing is motivated by the need to develop facilities for DOE programmatic needs; to maintain, replace and rehabilitatemore » existing obsolete facilities; to identify sites for anticipated programmatic growth; and to establish a planning framework in recognition of site amenities and the surrounding community. The CFP presents a concise expression of the policy for the future physical development of the Laboratory, based upon anticipated operational needs of research programs and the environmental setting. It is a product of the ongoing planning processes and is a dynamic information source.« less

  2. Facility 596, detail of ramp from below, with replacement sheetpile ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Facility 596, detail of ramp from below, with replacement sheet-pile dolphin on right and southernmost dolphins in background. - U.S. Naval Base, Pearl Harbor, Ferry Landing Type, Halawa Landing on Ford Island, Pearl City, Honolulu County, HI

  3. PILOT LAND TREATMENT OF PAH-CONTAMINATED SEDIMENTS

    EPA Science Inventory

    Hazardous dredged sediments are typically placed in confined disposal facilities (CDFs) which are designed to dewater and contain but not treat sediments. Since navigational dredging in the U.S. is quickly filling many CDFs, these facilities have little available capacity for ne...

  4. Challenges in implementing uncomplicated malaria treatment in children: a health facility survey in rural Malawi.

    PubMed

    Kabaghe, Alinune N; Phiri, Mphatso D; Phiri, Kamija S; van Vugt, Michèle

    2017-10-18

    Prompt and effective malaria treatment are key in reducing transmission, disease severity and mortality. With the current scale-up of artemisinin-based combination therapy (ACT) coverage, there is need to focus on challenges affecting implementation of the intervention. Routine indicators focus on utilization and coverage, neglecting implementation quality. A health system in rural Malawi was assessed for uncomplicated malaria treatment implementation in children. A cross-sectional health facility survey was conducted in six health centres around the Majete Wildlife Reserve in Chikwawa district using a health system effectiveness approach to assess uncomplicated malaria treatment implementation. Interviews with health facility personnel and exit interviews with guardians of 120 children under 5 years were conducted. Health workers appropriately prescribed an ACT and did not prescribe an ACT to 73% (95% CI 63-84%) of malaria rapid diagnostic test (RDT) positive and 98% (95% CI 96-100%) RDT negative children, respectively. However, 24% (95% CI 13-37%) of children receiving artemisinin-lumefantrine had an inappropriate dose by weight. Health facility findings included inadequate number of personnel (average: 2.1 health workers per 10,000 population), anti-malarial drug stock-outs or not supplied, and inconsistent health information records. Guardians of 59% (95% CI 51-69%) of children presented within 24 h of onset of child's symptoms. The survey presents an approach for assessing treatment effectiveness, highlighting bottlenecks which coverage indicators are incapable of detecting, and which may reduce quality and effectiveness of malaria treatment. Health service provider practices in prescribing and dosing anti-malarial drugs, due to drug stock-outs or high patient load, risk development of drug resistance, treatment failure and exposure to adverse effects.

  5. Land Disposal Restrictions for Hazardous Waste

    EPA Pesticide Factsheets

    The land disposal restrictions prohibits the land disposal of untreated hazardous wastes. EPA has specified either concentration levels or methods of treatment for hazardous constituents to meet before land disposal.

  6. Aeroacoustic Simulation of a Nose Landing Gear in an Open Jet Facility Using FUN3D

    NASA Technical Reports Server (NTRS)

    Vatsa, Veer N.; Lockard, David P.; Khorrami, Mehdi R.; Carlson, Jan-Renee

    2012-01-01

    Numerical simulations have been performed for a partially-dressed, cavity-closed nose landing gear configuration that was tested in NASA Langley s closed-wall Basic Aerodynamic Research Tunnel (BART) and in the University of Florida s open-jet acoustic facility known as UFAFF. The unstructured-grid flow solver, FUN3D, developed at NASA Langley Research center is used to compute the unsteady flow field for this configuration. A hybrid Reynolds-averaged Navier-Stokes/large eddy simulation (RANS/LES) turbulence model is used for these computations. Time-averaged and instantaneous solutions compare favorably with the measured data. Unsteady flowfield data obtained from the FUN3D code are used as input to a Ffowcs Williams-Hawkings noise propagation code to compute the sound pressure levels at microphones placed in the farfield. Significant improvement in predicted noise levels is obtained when the flowfield data from the open jet UFAFF simulations is used as compared to the case using flowfield data from the closed-wall BART configuration.

  7. A Policy Analysis: Military Medical Treatment Facility Contingency Inpatient Expansion

    DTIC Science & Technology

    2005-06-06

    Immunology 3 71B Biochemistry 2 Nurse Corps 66H Medical Surgical Nurse 688 66E Operating Room Nurse 72 66C Psychiatry 30 66N Nurse Administration 18...To) 06-06-2005 Final Report I July 2005 to July 2005 4. TITLE AND SUBTITLE 5a. CONTRACT NUMBER A Policy Analysis: Military Medical Treatment Facility...Contingency Inpatient Expansion 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT NUMBER Kalamaras, Peter Jr., Major, Medical

  8. Political economy of decentralising HIV and AIDS treatment services to primary healthcare facilities in three Nigerian states.

    PubMed

    Mbachu, Chinyere; Onwujekwe, Obinna; Ezumah, Nkoli; Ajayi, Olayinka; Sanwo, Olusola; Uzochukwu, Benjamin

    2016-09-01

    Decentralisation is defined as the dispersion, distribution or transfer of resources, functions and decision-making power from a central authority to regional and local authorities. It is usually accompanied by assignment of accountability and responsibility for results. Fundamental to understanding decentralisation is learning what motivates central governments to give up power and resources to local governments, and the practical significance of this on their positions regarding decentralisation. This study examined key political and institutional influences on role-players' capacity to support decentralisation of HIV and AIDS treatment services to primary healthcare facilities, and implications for sustainability. In-depth interviews were conducted with 55 purposively selected key informants, drawn from three Nigerian states that were at different stages of decentralising HIV and AIDS treatment services to primary care facilities. Key informants represented different categories of role-players involved in HIV and AIDS control programmes. Thematic framework analysis of data was done. Support for decentralisation of HIV and AIDS treatment services to primary healthcare facilities was substantial among different categories of actors. Political factors such as the local and global agenda for health, political tenure and party affiliations, and institutional factors such as consolidation of decision-making power and improvements in career trajectories, influenced role-players support for decentralisation of HIV and AIDS treatment services. It is feasible and acceptable to decentralise HIV and AIDS treatment services to primary healthcare facilities, to help improve coverage. However, role-players' support largely depends on how well the reform aligns with political structures and current institutional practices.

  9. 43 CFR 3162.6 - Well and facility identification.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 43 Public Lands: Interior 2 2014-10-01 2014-10-01 false Well and facility identification. 3162.6... for Operating Rights Owners and Operators § 3162.6 Well and facility identification. (a) Every well within a Federal or Indian lease or supervised agreement shall have a well indentification sign. All...

  10. 43 CFR 3162.6 - Well and facility identification.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 43 Public Lands: Interior 2 2012-10-01 2012-10-01 false Well and facility identification. 3162.6... for Operating Rights Owners and Operators § 3162.6 Well and facility identification. (a) Every well within a Federal or Indian lease or supervised agreement shall have a well indentification sign. All...

  11. 43 CFR 3162.6 - Well and facility identification.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 43 Public Lands: Interior 2 2013-10-01 2013-10-01 false Well and facility identification. 3162.6... for Operating Rights Owners and Operators § 3162.6 Well and facility identification. (a) Every well within a Federal or Indian lease or supervised agreement shall have a well indentification sign. All...

  12. Evaluation of outcomes of tuberculosis management in private for profit and private-not-for profit directly observed treatment short course facilities in Lagos State, Nigeria.

    PubMed

    Adejumo, Olusola Adedeji; Daniel, Olusoji James; Otesanya, Andrew Folarin; Salisu-Olatunj, Shukrat Olajumoke; Abdur-Razzaq, Husseine A

    2017-01-01

    The engagement of private practitioners in the public-private mix of tuberculosis (TB) management started in 2007 in Lagos State Nigeria. This study compared the treatment outcomes of patients managed at private for profit (PFP) and private not for profit (PNFP) directly observed treatment short course (DOTS) facilities. A retrospective review of treatment cards of TB patients managed between January 1, 2012, and June 30, 2012, in seven PFP and four PNFP DOTS facilities that served as treatment and microscopy center under the Lagos State TB and Leprosy Control Programme (LSTBLCP) at least 2 years before data collection was conducted. A total of 372 treatment cards of TB patients were reviewed, of which 132 (35.5%) and 240 (64.5%) were from PFP and PNFP DOTS facilities, respectively. Treatment success rate was higher among patients managed at PFP (89.4%) DOTS facilities than PNFP (81.3%) DOTS facilities ( P = 0.04). The proportion of patients lost to follow-up (12.5% vs. 8.3%), dead (3.3% vs. 1.5%) and treatment failure (2.5% vs. 0.8%) was higher among patients managed at PNFP DOTS facilities ( P > 0.05). The odds that patients treated at PFP DOTS facilities had treatment success were about four times higher than PNFP DOTS facilities when other variables have been controlled for ( P < 0.05). There is need by the LSTBLCP to engage more private practitioners to increase case detection and improve treatment outcomes of TB patients.

  13. Land Acquisition Practices of the Miami-Dade County School District. Special Review.

    ERIC Educational Resources Information Center

    Florida State Legislature, Tallahassee. Office of Program Policy Analysis and Government Accountability.

    This review, requested by the Florida Legislature, answers six questions about Miami-Dade County School District's land acquisition practices. The six questions are: (1) Does the district effectively identify its facility needs and plan for those needs? (2) Does the district acquire the land it needs? (3) Has the district adopted land acquisition…

  14. Village of Pender, Nebraska Wastewater Treatment Facility, Pender, Nebraska - Clean Water Act Public Notice

    EPA Pesticide Factsheets

    The EPA is providing notice of proposed Administrative Penalty Assessment against the Village of Pender, Nebraska Wastewater Treatment Facility (“Respondent”) for alleged violations of Sections 301 and/or 404 of the Clean Water Act

  15. Validating Innovative Renewable Energy Technologies: ESTCP Demonstrations at Two DoD Facilities

    DTIC Science & Technology

    2011-11-01

    4. TITLE AND SUBTITLE Validating Innovative Renewable Energy Technologies: ESTCP Demonstrations at Two DoD Facilities 5a. CONTRACT NUMBER 5b...goals of 25% of energy consumed required to be from renewable energy by 2025, the DoD has set aggressive, yet achievable targets. With its array of land...holdings facilities, and environments, the potential for renewable energy generation on DoD lands is great. Reaching these goals will require

  16. 43 CFR 3275.13 - How must the facility operator measure the geothermal resources?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 43 Public Lands: Interior 2 2012-10-01 2012-10-01 false How must the facility operator measure the geothermal resources? 3275.13 Section 3275.13 Public Lands: Interior Regulations Relating to Public Lands (Continued) BUREAU OF LAND MANAGEMENT, DEPARTMENT OF THE INTERIOR MINERALS MANAGEMENT (3000) GEOTHERMAL RESOURCE LEASING Conducting Utilizatio...

  17. 43 CFR 3275.13 - How must the facility operator measure the geothermal resources?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 43 Public Lands: Interior 2 2014-10-01 2014-10-01 false How must the facility operator measure the geothermal resources? 3275.13 Section 3275.13 Public Lands: Interior Regulations Relating to Public Lands (Continued) BUREAU OF LAND MANAGEMENT, DEPARTMENT OF THE INTERIOR MINERALS MANAGEMENT (3000) GEOTHERMAL RESOURCE LEASING Conducting Utilizatio...

  18. 43 CFR 3275.13 - How must the facility operator measure the geothermal resources?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 43 Public Lands: Interior 2 2011-10-01 2011-10-01 false How must the facility operator measure the geothermal resources? 3275.13 Section 3275.13 Public Lands: Interior Regulations Relating to Public Lands (Continued) BUREAU OF LAND MANAGEMENT, DEPARTMENT OF THE INTERIOR MINERALS MANAGEMENT (3000) GEOTHERMAL RESOURCE LEASING Conducting Utilizatio...

  19. 43 CFR 3275.13 - How must the facility operator measure the geothermal resources?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 43 Public Lands: Interior 2 2013-10-01 2013-10-01 false How must the facility operator measure the geothermal resources? 3275.13 Section 3275.13 Public Lands: Interior Regulations Relating to Public Lands (Continued) BUREAU OF LAND MANAGEMENT, DEPARTMENT OF THE INTERIOR MINERALS MANAGEMENT (3000) GEOTHERMAL RESOURCE LEASING Conducting Utilizatio...

  20. Historical Photograph of the Michoud Assembly Facility (MAF)

    NASA Technical Reports Server (NTRS)

    1963-01-01

    NASA's Michoud Assembly Facility, located in eastern New Orleans, Louisiana, is an 832 acre site that is a government-owned, contractor-operated component of the George C. Marshall Space Flight Center (MSFC). The facility was acquired by NASA in 1961 at the recommendation of Dr. Wernher von Braun and his rocket team in Huntsville Alabama. The cavernous plant served as the assembly facility for the Saturn launch vehicles and most recently the external tank (ET) used for the Space Shuttle Program. The facility features one of the world's biggest manufacturing plants with 43 acres under one roof and a port with deep-water access for the transportation of large space structures. When completed, space hardware is towed on a barge across the Gulf of Mexico, around Florida and up to Kennedy Space Center. The original tract of land was part of a 34,500 acre French Royal land grant to local merchant, Gilbert Antoine de St. Maxent in 1763. Later, the land was acquired by French transplant Antoine Michoud, the son of Napoleon's Administrator of Domains, who moved to the city in 1827. Michoud operated a sugar cane plantation and refinery on the site until his death in 1863. His heirs continued operating the refinery and kept the original St. Maxent estate intact into the 20th century. Two brick smokestacks from the original refinery still stand before the Michoud facility today as seen in the lower half of this photograph taken in the 1960's, while the upper half reflects the area during the time of the sugar cane plantation workers.

  1. Tobacco Cessation Interventions and Smoke-Free Policies in Mental Health and Substance Abuse Treatment Facilities - United States, 2016.

    PubMed

    Marynak, Kristy; VanFrank, Brenna; Tetlow, Sonia; Mahoney, Margaret; Phillips, Elyse; Jamal Mbbs, Ahmed; Schecter, Anna; Tipperman, Doug; Babb, Stephen

    2018-05-11

    Persons with mental or substance use disorders or both are more than twice as likely to smoke cigarettes as persons without such disorders and are more likely to die from smoking-related illness than from their behavioral health conditions (1,2). However, many persons with behavioral health conditions want to and are able to quit smoking, although they might require more intensive treatment (2,3). Smoking cessation reduces smoking-related disease risk and could improve mental health and drug and alcohol recovery outcomes (1,3,4). To assess tobacco-related policies and practices in mental health and substance abuse treatment facilities (i.e., behavioral health treatment facilities) in the United States (including Puerto Rico), CDC and the Substance Abuse and Mental Health Services Administration (SAMHSA) analyzed data from the 2016 National Mental Health Services Survey (N-MHSS) and the 2016 National Survey of Substance Abuse Treatment Services (N-SSATS). In 2016, among mental health treatment facilities, 48.9% reported screening patients for tobacco use, 37.6% offered tobacco cessation counseling, 25.2% offered nicotine replacement therapy (NRT), 21.5% offered non-nicotine tobacco cessation medications, and 48.6% prohibited smoking in all indoor and outdoor locations (i.e., smoke-free campus). In 2016, among substance abuse treatment facilities, 64.0% reported screening patients for tobacco use, 47.4% offered tobacco cessation counseling, 26.2% offered NRT, 20.3% offered non-nicotine tobacco cessation medications, and 34.5% had smoke-free campuses. Full integration of tobacco cessation interventions into behavioral health treatment, coupled with implementation of tobacco-free campus policies in behavioral health treatment settings, could decrease tobacco use and tobacco-related disease and could improve behavioral health outcomes among persons with mental and substance use disorders (1-4).

  2. Opportunities for Combined Heat and Power at Wastewater Treatment Facilities: Market Analysis and Lessons from the Field

    EPA Pesticide Factsheets

    This report presents the opportunities for combined heat and power (CHP) applications in the municipal wastewater treatment sector, and it documents the experiences of the wastewater treatment facility (WWTF) operators who have employed CHP.

  3. Patients' costs and cost-effectiveness of tuberculosis treatment in DOTS and non-DOTS facilities in Rio de Janeiro, Brazil.

    PubMed

    Steffen, Ricardo; Menzies, Dick; Oxlade, Olivia; Pinto, Marcia; de Castro, Analia Zuleika; Monteiro, Paula; Trajman, Anete

    2010-11-17

    Costs of tuberculosis diagnosis and treatment may represent a significant burden for the poor and for the health system in resource-poor countries. The aim of this study was to analyze patients' costs of tuberculosis care and to estimate the incremental cost-effectiveness ratio (ICER) of the directly observed treatment (DOT) strategy per completed treatment in Rio de Janeiro, Brazil. We interviewed 218 adult patients with bacteriologically confirmed pulmonary tuberculosis. Information on direct (out-of-pocket expenses) and indirect (hours lost) costs, loss in income and costs with extra help were gathered through a questionnaire. Healthcare system additional costs due to supervision of pill-intake were calculated considering staff salaries. Effectiveness was measured by treatment completion rate. The ICER of DOT compared to self-administered therapy (SAT) was calculated. DOT increased costs during the treatment phase, while SAT increased costs in the pre-diagnostic phase, for both the patient and the health system. Treatment completion rates were 71% in SAT facilities and 79% in DOT facilities. Costs per completed treatment were US$ 194 for patients and U$ 189 for the health system in SAT facilities, compared to US$ 336 and US$ 726 in DOT facilities. The ICER was US$ 6,616 per completed DOT treatment compared to SAT. Costs incurred by TB patients are high in Rio de Janeiro, especially for those under DOT. The DOT strategy doubles patients' costs and increases by fourfold the health system costs per completed treatment. The additional costs for DOT may be one of the contributing factors to the completion rates below the targeted 85% recommended by WHO.

  4. Soil stabilization mat for lunar launch/landing site

    NASA Technical Reports Server (NTRS)

    Acord, Amy L.; Cohenour, Mark W.; Ephraim, Daniel; Gochoel, Dennis; Roberts, Jefferson G.

    1990-01-01

    Facilities which are capable of handling frequent arrivals and departures of spaceships between Earth and a lunar colony are necessary. The facility must be able to provide these services with minimal interruption of operational activity within the colony. The major concerns associated with the space traffic are the dust and rock particles that will be kicked up by the rocket exhaust. As a result of the reduced gravitation of the Moon, these particles scatter over large horizontal distances. This flying debris will not only seriously interrupt the routine operations of the colony, but could cause damage to the equipment and facilities surrounding the launch site. An approach to overcome this problem is presented. A proposed design for a lunar take-off/landing mat is presented. This proposal goes beyond dealing with the usual problems of heat and load resistances associated with take-off and landing, by solving the problem of soil stabilization at the site. Through adequate stabilization, the problem of flying debris is eliminated.

  5. Selecting reasonable future land use scenarios

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Allred, W.E.; Smith, R.W.

    1995-12-31

    This paper examines a process to help select the most reasonable future land use scenarios for hazardous waste and/or low-level radioactive waste disposal sites. The process involves evaluating future land use scenarios by applying selected criteria currently used by commercial mortgage companies to determine the feasibility of obtaining a loan for purchasing such land. The basis for the process is that only land use activities for which a loan can be obtained will be considered. To examine the process, a low-level radioactive waste site, the Radioactive Waste Management Complex at the Idaho National Engineering Laboratory, is used as an example.more » The authors suggest that the process is a very precise, comprehensive, and systematic (common sense) approach for determining reasonable future use of land. Implementing such a process will help enhance the planning, decisionmaking, safe management, and cleanup of present and future disposal facilities.« less

  6. Facile Dry Surface Cleaning of Graphene by UV Treatment

    NASA Astrophysics Data System (ADS)

    Kim, Jin Hong; Haidari, Mohd Musaib; Choi, Jin Sik; Kim, Hakseong; Yu, Young-Jun; Park, Jonghyurk

    2018-05-01

    Graphene has been considered an ideal material for application in transparent lightweight wearable electronics due to its extraordinary mechanical, optical, and electrical properties originating from its ordered hexagonal carbon atomic lattice in a layer. Precise surface control is critical in maximizing its performance in electronic applications. Graphene grown by chemical vapor deposition is widely used but it produces polymeric residue following wet/chemical transfer process, which strongly affects its intrinsic electrical properties and limits the doping efficiency by adsorption. Here, we introduce a facile dry-cleaning method based on UV irradiation to eliminate the organic residues even after device fabrication. Through surface topography, Raman analysis, and electrical transport measurement characteristics, we confirm that the optimized UV treatment can recover the clean graphene surface and improve graphene-FET performance more effectively than thermal treatment. We propose our UV irradiation method as a systematically controllable and damage-free post process for application in large-area devices.

  7. 32 CFR 766.11 - Fees for landing, parking and storage.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 32 National Defense 5 2011-07-01 2011-07-01 false Fees for landing, parking and storage. 766.11 Section 766.11 National Defense Department of Defense (Continued) DEPARTMENT OF THE NAVY MISCELLANEOUS RULES USE OF DEPARTMENT OF THE NAVY AVIATION FACILITIES BY CIVIL AIRCRAFT § 766.11 Fees for landing...

  8. Recycled Water Reuse Permit Renewal Application for the Central Facilities Area Sewage Treatment Plant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lewis, Mike

    This renewal application for a Recycled Water Reuse Permit is being submitted in accordance with the Idaho Administrative Procedures Act 58.01.17 “Recycled Water Rules” and the Municipal Wastewater Reuse Permit LA-000141-03 for continuing the operation of the Central Facilities Area Sewage Treatment Plant located at the Idaho National Laboratory. The permit expires March 16, 2015. The permit requires a renewal application to be submitted six months prior to the expiration date of the existing permit. For the Central Facilities Area Sewage Treatment Plant, the renewal application must be submitted by September 16, 2014. The information in this application is consistentmore » with the Idaho Department of Environmental Quality’s Guidance for Reclamation and Reuse of Municipal and Industrial Wastewater and discussions with Idaho Department of Environmental Quality personnel.« less

  9. Research and test facilities

    NASA Technical Reports Server (NTRS)

    1993-01-01

    A description is given of each of the following Langley research and test facilities: 0.3-Meter Transonic Cryogenic Tunnel, 7-by 10-Foot High Speed Tunnel, 8-Foot Transonic Pressure Tunnel, 13-Inch Magnetic Suspension & Balance System, 14-by 22-Foot Subsonic Tunnel, 16-Foot Transonic Tunnel, 16-by 24-Inch Water Tunnel, 20-Foot Vertical Spin Tunnel, 30-by 60-Foot Wind Tunnel, Advanced Civil Transport Simulator (ACTS), Advanced Technology Research Laboratory, Aerospace Controls Research Laboratory (ACRL), Aerothermal Loads Complex, Aircraft Landing Dynamics Facility (ALDF), Avionics Integration Research Laboratory, Basic Aerodynamics Research Tunnel (BART), Compact Range Test Facility, Differential Maneuvering Simulator (DMS), Enhanced/Synthetic Vision & Spatial Displays Laboratory, Experimental Test Range (ETR) Flight Research Facility, General Aviation Simulator (GAS), High Intensity Radiated Fields Facility, Human Engineering Methods Laboratory, Hypersonic Facilities Complex, Impact Dynamics Research Facility, Jet Noise Laboratory & Anechoic Jet Facility, Light Alloy Laboratory, Low Frequency Antenna Test Facility, Low Turbulence Pressure Tunnel, Mechanics of Metals Laboratory, National Transonic Facility (NTF), NDE Research Laboratory, Polymers & Composites Laboratory, Pyrotechnic Test Facility, Quiet Flow Facility, Robotics Facilities, Scientific Visualization System, Scramjet Test Complex, Space Materials Research Laboratory, Space Simulation & Environmental Test Complex, Structural Dynamics Research Laboratory, Structural Dynamics Test Beds, Structures & Materials Research Laboratory, Supersonic Low Disturbance Pilot Tunnel, Thermal Acoustic Fatigue Apparatus (TAFA), Transonic Dynamics Tunnel (TDT), Transport Systems Research Vehicle, Unitary Plan Wind Tunnel, and the Visual Motion Simulator (VMS).

  10. Neutron medical treatment of tumours — a survey of facilities

    NASA Astrophysics Data System (ADS)

    Wagner, F. M.; Loeper-Kabasakal, B.; Breitkreutz, H.

    2012-03-01

    Neutron therapy has two branches: Fast Neutron Therapy (FNT) and Boron Neutron Capture Therapy (BNCT). The mean neutron energies used for FNT range from 2 MeV to 25 MeV whereas the maximum energy for BNCT is about 10 keV. Neutron generators for FNT have been cyclotrons, accelerators and reactors, whereas BNCT is so far bound to reactors. Both therapies use the effects of high-LET radiation (secondary recoil protons and alpha particles, respectively) and can attack otherwise radioresistant tumours, however, with the hazard of adverse effects for irradiated healthy tissue. FNT has been administered to about 30,000 patients world-wide. From formerly 40 facilities, only eight are operational or stand-by today. The reasons for this development have been, on the one hand, related to technical and economical conditions; on the other hand, strong side effects and insufficient proof of clinical results in the early years as well as increasing competition with new clinical methods have reduced patient numbers. In fact, strict observations of indications, appropriate therapy-planning including low-LET radiation, and consequent treatment of side effects have lead to remarkable results in the meantime. BNCT initially was developed for the treatment of extremely aggressive forms of brain tumour, taking advantage of the action of the blood-brain-barrier which allows for a boronated compound to be selectively enriched in tumour cells. Meanwhile, also malignant melanoma (MM) and Head-and-Neck (H&T) tumours are treated because of their relative radioresistance. At present, epithermal beams with sufficient flux are available only at two facilities. Existing research reactors were indispensable in the development of BNCT, but are to be replaced by hospital-based epithermal neutron sources. Clinical results indicate significantly increased survival times, but the number of patients ever treated is still below 1,000. 3D-dose calculation systems have been developed at several facilities

  11. Factsheets - Division of Mining, Land, and Water

    Science.gov Websites

    Recreational Mining Area PDF Commercial Recreation Day Use Registration PDF Commercial Recreation Facility Programs PDF Off-Road Travel On The North Slope On State Land PDF Permits for Commercial Recreation

  12. Nasreya: a treatment and disposal facility for industrial hazardous waste in Alexandria, Egypt: phase I.

    PubMed

    Ramadan, Adham R; Kock, Per; Nadim, Amani

    2005-04-01

    A facility for the treatment and disposal of industrial hazardous waste has been established in Alexandria, Egypt. Phase I of the facility encompassing a secure landfill and solar evaporation ponds is ready to receive waste, and Phase II encompassing physico-chemical treatment, solidification, and interim storage is underway. The facility, the Nasreya Centre, is the first of its kind in Egypt, and represents the nucleus for the integration, improvement and further expansion of different hazardous waste management practices and services in Alexandria. It has been developed within the overall legal framework of the Egyptian Law for the Environment, and is expected to improve prospects for enforcement of the regulatory requirements specified in this law. It has been developed with the overall aim of promoting the establishment of an integrated industrial hazardous waste management system in Alexandria, serving as a demonstration to be replicated elsewhere in Egypt. For Phase I, the Centre only accepts inorganic industrial wastes. In this respect, a waste acceptance policy has been developed, which is expected to be reviewed during Phase II, with an expansion of the waste types accepted.

  13. EFFLUENT TREATMENT FACILITY PEROXIDE DESTRUCTION CATALYST TESTING

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    HALGREN DL

    2008-07-30

    The 200 Area Effluent Treatment Facility (ETF) main treatment train includes the peroxide destruction module (PDM) where the hydrogen peroxide residual from the upstream ultraviolet light/hydrogen peroxide oxidation unit is destroyed. Removal of the residual peroxide is necessary to protect downstream membranes from the strong oxidizer. The main component of the PDM is two reaction vessels utilizing granular activated carbon (GAC) as the reaction media. The PDM experienced a number of operability problems, including frequent plugging, and has not been utilized since the ETF changed to groundwater as the predominant feed. The unit seemed to be underperforming in regards tomore » peroxide removal during the early periods of operation as well. It is anticipated that a functional PDM will be required for wastewater from the vitrification plant and other future streams. An alternate media or methodology needs to be identified to replace the GAC in the PDMs. This series of bench scale tests is to develop information to support an engineering study on the options for replacement of the existing GAC method for peroxide destruction at the ETF. A number of different catalysts will be compared as well as other potential methods such as strong reducing agents. The testing should lead to general conclusions on the viability of different catalysts and identify candidates for further study and evaluation.« less

  14. KENNEDY SPACE CENTER, FLA. - In the Launch Control Center, officials monitor the “Mode VII” emergency landing simulation being conducted at Kennedy Space Center and managed and directed from the LCC. From left are Dr. Luis Moreno and Dr. David Reed, with Bionetics Life Sciences, and Dr. Philip Scarpa, with the KSC Safety, Occupational Health and Environment Division. The purpose of the Mode VII is to exercise emergency preparedness personnel, equipment and facilities in rescuing astronauts from a downed orbiter and providing immediate medical attention. This simulation presents an orbiter that has crashed short of the Shuttle Landing Facility in a wooded area 2-1/2 miles south of Runway 33. Emergency crews are responding to the volunteer “astronauts” who are simulating various injuries inside the crew compartment mock-up. Rescuers must remove the crew, provide triage and transport to hospitals those who need further treatment. Local hospitals are participating in the exercise.

    NASA Image and Video Library

    2004-02-18

    KENNEDY SPACE CENTER, FLA. - In the Launch Control Center, officials monitor the “Mode VII” emergency landing simulation being conducted at Kennedy Space Center and managed and directed from the LCC. From left are Dr. Luis Moreno and Dr. David Reed, with Bionetics Life Sciences, and Dr. Philip Scarpa, with the KSC Safety, Occupational Health and Environment Division. The purpose of the Mode VII is to exercise emergency preparedness personnel, equipment and facilities in rescuing astronauts from a downed orbiter and providing immediate medical attention. This simulation presents an orbiter that has crashed short of the Shuttle Landing Facility in a wooded area 2-1/2 miles south of Runway 33. Emergency crews are responding to the volunteer “astronauts” who are simulating various injuries inside the crew compartment mock-up. Rescuers must remove the crew, provide triage and transport to hospitals those who need further treatment. Local hospitals are participating in the exercise.

  15. KENNEDY SPACE CENTER, FLA. - Volunteers from the KSC Fire-Rescue team dressed in launch and entry suits settle into seats in an orbiter crew compartment mock-up under the guidance of George Brittingham, USA suit technician on the Closeout Crew. Brittingham is helping Catherine Di Biase, a nurse with Bionetics Life Sciences. They are all taking part in a “Mode VII” emergency landing simulation at Kennedy Space Center. The purpose is to exercise emergency preparedness personnel, equipment and facilities in rescuing astronauts from a downed orbiter and providing immediate medical attention. This simulation presents an orbiter that has crashed short of the Shuttle Landing Facility in a wooded area 2-1/2 miles south of Runway 33. Emergency crews will respond to the volunteer “astronauts” simulating various injuries. Rescuers must remove the crew, provide triage and transport to hospitals those who need further treatment. Local hospitals are participating in the exercise.

    NASA Image and Video Library

    2004-02-18

    KENNEDY SPACE CENTER, FLA. - Volunteers from the KSC Fire-Rescue team dressed in launch and entry suits settle into seats in an orbiter crew compartment mock-up under the guidance of George Brittingham, USA suit technician on the Closeout Crew. Brittingham is helping Catherine Di Biase, a nurse with Bionetics Life Sciences. They are all taking part in a “Mode VII” emergency landing simulation at Kennedy Space Center. The purpose is to exercise emergency preparedness personnel, equipment and facilities in rescuing astronauts from a downed orbiter and providing immediate medical attention. This simulation presents an orbiter that has crashed short of the Shuttle Landing Facility in a wooded area 2-1/2 miles south of Runway 33. Emergency crews will respond to the volunteer “astronauts” simulating various injuries. Rescuers must remove the crew, provide triage and transport to hospitals those who need further treatment. Local hospitals are participating in the exercise.

  16. 25 CFR 170.800 - Who owns IRR transportation facilities?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false Who owns IRR transportation facilities? 170.800 Section 170.800 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR LAND AND WATER INDIAN RESERVATION ROADS PROGRAM BIA Road Maintenance § 170.800 Who owns IRR transportation facilities? Public authorities...

  17. Land Application of Wastes: An Educational Program. Treatment Systems, Effluent Qualities, and Costs - Module 4, Objectives, Script, and Booklet.

    ERIC Educational Resources Information Center

    Clarkson, W. W.; And Others

    This module describes the following conventional treatment systems and evaluates their use as pretreatment steps for land application: preliminary, primary, secondary, disinfection, and advanced waste treatment. Effluent qualities are summarized, a brief discussion of application systems is given, and cost comparisons are discussed in some detail.…

  18. 1998 report on Hanford Site land disposal restrictions for mixed waste

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Black, D.G.

    1998-04-10

    This report was submitted to meet the requirements of Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement) Milestone M-26-01H. This milestone requires the preparation of an annual report that covers characterization, treatment, storage, minimization, and other aspects of managing land-disposal-restricted mixed waste at the Hanford Facility. The US Department of Energy, its predecessors, and contractors on the Hanford Facility were involved in the production and purification of nuclear defense materials from the early 1940s to the late 1980s. These production activities have generated large quantities of liquid and solid mixed waste. This waste is regulated under authority of bothmore » the Resource Conservation and Recovery Act of l976 and the Atomic Energy Act of 1954. This report covers only mixed waste. The Washington State Department of Ecology, US Environmental Protection Agency, and US Department of Energy have entered into the Tri-Party Agreement to bring the Hanford Facility operations into compliance with dangerous waste regulations. The Tri-Party Agreement required development of the original land disposal restrictions (LDR) plan and its annual updates to comply with LDR requirements for mixed waste. This report is the eighth update of the plan first issued in 1990. The Tri-Party Agreement requires and the baseline plan and annual update reports provide the following information: (1) Waste Characterization Information -- Provides information about characterizing each LDR mixed waste stream. The sampling and analysis methods and protocols, past characterization results, and, where available, a schedule for providing the characterization information are discussed. (2) Storage Data -- Identifies and describes the mixed waste on the Hanford Facility. Storage data include the Resource Conservation and Recovery Act of 1976 dangerous waste codes, generator process knowledge needed to identify the waste and to make LDR determinations

  19. Cost-effectiveness of the treatment of uncomplicated severe acute malnutrition by community health workers compared to treatment provided at an outpatient facility in rural Mali.

    PubMed

    Rogers, Eleanor; Martínez, Karen; Morán, Jose Luis Alvarez; Alé, Franck G B; Charle, Pilar; Guerrero, Saul; Puett, Chloe

    2018-02-20

    The Malian Nutrition Division of the Ministry of Health and Action Against Hunger tested the feasibility of integrating treatment of severe acute malnutrition (SAM) into the existing Integrated Community Case Management package delivered by community health workers (CHWs). This study assessed costs and cost-effectiveness of CHW-delivered care compared to outpatient facility-based care. Activity-based costing methods were used, and a societal perspective employed to include all relevant costs incurred by institutions, beneficiaries and communities. The intervention and control arm enrolled different numbers of children so a modelled scenario sensitivity analysis was conducted to assess the cost-effectiveness of the two arms, assuming equal numbers of children enrolled. In the base case, with unequal numbers of children in each arm, for CHW-delivered care, the cost per child treated was 244 USD and cost per child recovered was 259 USD. Outpatient facility-based care was less cost-effective at 442 USD per child and 501 USD per child recovered. The conclusions of the analysis changed in the modelled scenario sensitivity analysis, with outpatient facility-based care being marginally more cost-effective (cost per child treated is 188 USD, cost per child recovered is 214 USD), compared to CHW-delivered care. This suggests that achieving good coverage is a key factor influencing cost-effectiveness of CHWs delivering treatment for SAM in this setting. Per week of treatment, households receiving CHW-delivered care spent half of the time receiving treatment and three times less money compared with those receiving treatment from the outpatient facility. This study supports existing evidence that the delivery of treatment by CHWs is a cost-effective intervention, provided that good coverage is achieved. A major benefit of this strategy was the lower cost incurred by the beneficiary household when treatment is available in the community. Further research is needed on the

  20. Strengthening Critical Infrastructure: Combined Heat and Power at Wastewater Treatment Facilities (Webinar) – November 15, 2011

    EPA Pesticide Factsheets

    This webinar provides information about CHP at wastewater treatment facilities (WWTFs), including advantages and challenges, financial incentives and funding programs, and technical and economic potential.

  1. Effectiveness of aquatic versus land physiotherapy in the treatment of peripheral neuropathies: a randomized controlled trial

    PubMed Central

    Zivi, Ilaria; Maffia, Sara; Ferrari, Vanessa; Zarucchi, Alessio; Molatore, Katia; Maestri, Roberto; Frazzitta, Giuseppe

    2017-01-01

    Objective: To compare the effects on gait and balance of aquatic physiotherapy versus on-land training, in the context of an inpatient rehabilitation treatment tailored for peripheral neuropathies. Design: Parallel-group, single-center, single-blind randomized controlled trial. Subjects and setting: Consecutive patients affected by peripheral neuropathy admitted in our Neuro-Rehabilitation Unit. Interventions: Patients received a four-week rehabilitation program composed by daily sessions of conventional physiotherapy and three sessions/week of specific treatment (aquatic vs. on-land). Main measures: Primary outcome measures were Berg Balance Scale and Dynamic Gait Index. Secondary outcome measures were Neuropathic Pain Scale, Overall Neuropathy Limitations Scale, Functional Independence Measure, Functional Ambulation Classification, Conley Scale and Medical Research Council Scale score for the strength of hip and ankle flexor and extensor muscles. For each scale, we calculated the difference between the scores at discharge and admission and compared it between the two groups. Results: Forty patients were enrolled: 21 in the water-based rehabilitation group and 19 in the land-based one. Patients were similar between groups. When comparing the groups, we found that “in-water” patients had a significant better improvement in the Dynamic Gait Index score (6.00 (4.00, 7.25) vs. 4.00 (1.25, 6.00), P = 0.0433). On the opposite, the “on-land” group showed a better improvement of the Functional Ambulation Classification score (1.0 (0.75, 1.0) vs. 1.0 (1.0, 2.0), P = 0.0386). Conclusion: Aquatic physiotherapy showed an effect comparable to the land-based rehabilitation on gait and balance dysfunctions of neuropathic patients. PMID:29232980

  2. NPDES Permit for Dakota Magic Casino and Hotel Wastewater Treatment Facility in North Dakota

    EPA Pesticide Factsheets

    Under NPDES permit ND0030813, the the Dakota Magic Casino and Hotel is authorized is authorized to discharge from its wastewater treatment facility in Richland County, North Dakota, to a roadside ditch flowing to an unnamed tributary to the Bois de Sioux.

  3. Sampling. Operational Control Tests for Wastewater Treatment Facilities. Instructor's Manual [and] Student Workbook.

    ERIC Educational Resources Information Center

    Carnegie, John W.

    A brief overview of the basic concepts and philosophies for sampling water and waste water systems is presented in this module. The module is not intended to specify sampling procedures, frequencies, or locations for specific treatment facilities but rather to outline those general procedures which should be followed when sampling under most…

  4. Landing of STS-63 Discovery at KSC

    NASA Technical Reports Server (NTRS)

    1995-01-01

    The Space Shuttle Discovery deploys its drag chute on Runway 15 at the Kennedy Space Center's (KSC) Shuttle Landing Facility as it completes an eight day mission. Touchdown occurred at 6:50:19 a.m. (EST), February 11, 1995.

  5. Landing of STS-63 Discovery at KSC

    NASA Technical Reports Server (NTRS)

    1995-01-01

    The Space Shuttle Discovery is about to touch down on Runway 15 at the Kennedy Space Center's (KSC) Shuttle Landing Facility to complete an eight day mission. Touchdown occurred at 6:50:19 a.m. (EST), February 11, 1995.

  6. 77 FR 19683 - Proposed Information Collection; Land-Based Wind Energy Guidelines

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-02

    ...-FF09F20000] Proposed Information Collection; Land-Based Wind Energy Guidelines AGENCY: Fish and Wildlife..., on an emergency basis, our request to collect information associated with the Land- Based Wind Energy... proposed wind energy facilities may have on wildlife and their habitat. OMB approved our request and...

  7. Land mobile radio system phase II deployment report

    DOT National Transportation Integrated Search

    2007-12-28

    In July 2004, the Alaska Department of Transportation and Public Facilities developed an integration methodology for Land Mobile Radio into the Departments Statewide Intelligent Transportation Systems Deployment Plan and the State Information Tech...

  8. Integrated Facilities Management and Fixed Asset Accounting.

    ERIC Educational Resources Information Center

    Golz, W. C., Jr.

    1984-01-01

    A record of a school district's assets--land, buildings, machinery, and equipment--can be a useful management tool that meets accounting requirements and provides appropriate information for budgeting, forecasting, and facilities management. (MLF)

  9. Relationships between ambient geochemistry, watershed land-use and trace metal concentrations in aquatic invertebrates living in stormwater treatment ponds

    USGS Publications Warehouse

    Karouna-Renier, N.K.; Sparling, D.W.

    2001-01-01

    Stormwater treatment ponds receive elevated levels of metals from urban runoff, but the effects of these pollutants on organisms residing in the ponds are unknown. We investigated the accumulation of Cu, Zn, and Pb by macroinvertebrates collected from stormwater treatment ponds in Maryland serving commercial, highway, residential and open-space watersheds, and determined whether watershed land-use classification influences metal concentrations in macroinvertebrates, sediments, and water. Three types of invertebrate samples were analyzed for molluscs, odonates, and composite. Zn concentrations in odonates from ponds draining watersheds with commercial development (mean=113.82 ug/g) were significantly higher than concentrations in the other land-use categories. Similarly, Cu levels in odonates from commercial ponds (mean=27.12 ug/g) were significantly higher than from highway (mean=20.23 ug/g) and open space (mean=17.79 ug/g) ponds. However, metal concentrations in sediments and water did not differ significantly among land-uses. The results suggest that despite the high variation in ambient metal concentrations within each land-use category, macroinvertebrates in ponds serving commercial watersheds accumulate higher levels of Cu and Zn. The levels of Cu, Zn, and Pb in invertebrates from all ponds were less than dietary concentrations considered toxic to fish.

  10. Detailed costing document for the centralized waste treatment industry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1998-12-01

    In this document, EPA presents the costs estimated for compliance with the proposed CWT effluent limitations guidelines and standards. Section 1 provides a general description of how the individual treatment technology and regulatory option costs were developed. In Sections 2 through 4, EPA describes the development of costs for each of the wastewater and sludge treatment technologies. In Section 5, EPA presents additional compliance costs to be incurred by facilities, which are not technology specific. These additional items are retrofit costs, monitoring costs, RCRA permit modification costs, and land costs.

  11. Numerical simulation of the actuation system for the ALDF's propulsion control valve. [Aircraft Landing Dynamics Facility

    NASA Technical Reports Server (NTRS)

    Korte, John J.

    1990-01-01

    A numerical simulation of the actuation system for the propulsion control valve (PCV) of the NASA Langley Aircraft Landing Dynamics Facility was developed during the preliminary design of the PCV and used throughout the entire project. The simulation is based on a predictive model of the PCV which is used to evaluate and design the actuation system. The PCV controls a 1.7 million-pound thrust water jet used in propelling a 108,000-pound test carriage. The PCV can open and close in 0.300 second and deliver over 9,000 gallons of water per sec at pressures up to 3150 psi. The numerical simulation results are used to predict transient performance and valve opening characteristics, specify the hydraulic control system, define transient loadings on components, and evaluate failure modes. The mathematical model used for numerically simulating the mechanical fluid power system is described, and numerical results are demonstrated for a typical opening and closing cycle of the PCV. A summary is then given on how the model is used in the design process.

  12. Landing of STS-63 Discovery at KSC

    NASA Technical Reports Server (NTRS)

    1995-01-01

    The main gear of the Space Shuttle Discovery touches down on Runway 15 at the Kennedy Space Center's (KSC) Shuttle Landing Facility to complete an eight day mission. Touchdown occurred at 6:50:19 a.m. (EST), February 11, 1995.

  13. Parameter Calculation Technique for the Waste Treatment Facilities Using Naturally-Aerated Blocks in the Bog Ecosystems

    NASA Astrophysics Data System (ADS)

    Akhmed-Ogly, K. V.; Savichev, O. G.; Tokarenko, O. G.; Pasechnik, E. Yu; Reshetko, M. V.; Nalivajko, N. G.; Vlasova, M. V.

    2014-08-01

    Technique for the domestic wastewater treatment in the small residential areas and oil and gas facilities of the natural and man-made systems including a settling tank for mechanical treatment and a biological pond with peat substrate and bog vegetation for biological treatment has been substantiated. Technique for parameters calculation of the similar natural and man-made systems has been developed. It was proven that effective treatment of wastewater can be performed in Siberia all year round.

  14. The Mars Science Laboratory Touchdown Test Facility

    NASA Technical Reports Server (NTRS)

    White, Christopher; Frankovich, John; Yates, Phillip; Wells Jr, George H.; Losey, Robert

    2009-01-01

    In the Touchdown Test Program for the Mars Science Laboratory (MSL) mission, a facility was developed to use a full-scale rover vehicle and an overhead winch system to replicate the Skycrane landing event.

  15. Study on patient-induced radioactivity during proton treatment in hengjian proton medical facility.

    PubMed

    Wu, Qingbiao; Wang, Qingbin; Liang, Tianjiao; Zhang, Gang; Ma, Yinglin; Chen, Yu; Ye, Rong; Liu, Qiongyao; Wang, Yufei; Wang, Huaibao

    2016-09-01

    At present, increasingly more proton medical facilities have been established globally for better curative effect and less side effect in tumor treatment. Compared with electron and photon, proton delivers more energy and dose at its end of range (Bragg peak), and has less lateral scattering for its much larger mass. However, proton is much easier to produce neutron and induced radioactivity, which makes radiation protection for proton accelerators more difficult than for electron accelerators. This study focuses on the problem of patient-induced radioactivity during proton treatment, which has been ignored for years. However, we confirmed it is a vital factor for radiation protection to both patient escort and positioning technician, by FLUKA's simulation and activation formula calculation of Hengjian Proton Medical Facility (HJPMF), whose energy ranges from 130 to 230MeV. Furthermore, new formulas for calculating the activity buildup process of periodic irradiation were derived and used to study the relationship between saturation degree and half-life of nuclides. Finally, suggestions are put forward to lessen the radiation hazard from patient-induced radioactivity. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Infection prevention and control in deployed military medical treatment facilities.

    PubMed

    Hospenthal, Duane R; Green, Andrew D; Crouch, Helen K; English, Judith F; Pool, Jane; Yun, Heather C; Murray, Clinton K

    2011-08-01

    Infections have complicated the care of combat casualties throughout history and were at one time considered part of the natural history of combat trauma. Personnel who survived to reach medical care were expected to develop and possibly succumb to infections during their care in military hospitals. Initial care of war wounds continues to focus on rapid surgical care with debridement and irrigation, aimed at preventing local infection and sepsis with bacteria from the environment (e.g., clostridial gangrene) or the casualty's own flora. Over the past 150 years, with the revelation that pathogens can be spread from patient to patient and from healthcare providers to patients (including via unwashed hands of healthcare workers, the hospital environment and fomites), a focus on infection prevention and control aimed at decreasing transmission of pathogens and prevention of these infections has developed. Infections associated with combat-related injuries in the recent operations in Iraq and Afghanistan have predominantly been secondary to multidrug-resistant pathogens, likely acquired within the military healthcare system. These healthcare-associated infections seem to originate throughout the system, from deployed medical treatment facilities through the chain of care outside of the combat zone. Emphasis on infection prevention and control, including hand hygiene, isolation, cohorting, and antibiotic control measures, in deployed medical treatment facilities is essential to reducing these healthcare-associated infections. This review was produced to support the Guidelines for the Prevention of Infections Associated With Combat-Related Injuries: 2011 Update contained in this supplement of Journal of Trauma.

  17. Satisfaction with general practitioner treatment of depression among residents of aged care facilities.

    PubMed

    Mellor, David; Davison, Tanya; McCabe, Marita; Kuruvilla, George; Moore, Kathleen; Ski, Chantal

    2006-06-01

    This article investigates consumer perspectives on the treatment for depression among older people in residential facilities. Aged care residents who were aware of being treated for depression in the past 6 months (24 women and 7 men, mean age = 83 years) participated in an interview that assessed their perspective on treatments. Although more than half of the participants in the sample reported overall satisfaction with the medical treatments received for depression, qualitative data provided indications of unsatisfactory service delivery, including perceptions of low treatment efficacy, short consultation times, the failure to assess affective symptomatology, and negative responses to residents' disclosure of symptoms. The findings are discussed in relation to previous research on consumer satisfaction with health services and issues that may be pertinent to the elderly depressed. Training for general practitioners providing treatment in aged care is indicated.

  18. Multi-country analysis of treatment costs for HIV/AIDS (MATCH): facility-level ART unit cost analysis in Ethiopia, Malawi, Rwanda, South Africa and Zambia.

    PubMed

    Tagar, Elya; Sundaram, Maaya; Condliffe, Kate; Matatiyo, Blackson; Chimbwandira, Frank; Chilima, Ben; Mwanamanga, Robert; Moyo, Crispin; Chitah, Bona Mukosha; Nyemazi, Jean Pierre; Assefa, Yibeltal; Pillay, Yogan; Mayer, Sam; Shear, Lauren; Dain, Mary; Hurley, Raphael; Kumar, Ritu; McCarthy, Thomas; Batra, Parul; Gwinnell, Dan; Diamond, Samantha; Over, Mead

    2014-01-01

    Today's uncertain HIV funding landscape threatens to slow progress towards treatment goals. Understanding the costs of antiretroviral therapy (ART) will be essential for governments to make informed policy decisions about the pace of scale-up under the 2013 WHO HIV Treatment Guidelines, which increase the number of people eligible for treatment from 17.6 million to 28.6 million. The study presented here is one of the largest of its kind and the first to describe the facility-level cost of ART in a random sample of facilities in Ethiopia, Malawi, Rwanda, South Africa and Zambia. In 2010-2011, comprehensive data on one year of facility-level ART costs and patient outcomes were collected from 161 facilities, selected using stratified random sampling. Overall, facility-level ART costs were significantly lower than expected in four of the five countries, with a simple average of $208 per patient-year (ppy) across Ethiopia, Malawi, Rwanda and Zambia. Costs were higher in South Africa, at $682 ppy. This included medications, laboratory services, direct and indirect personnel, patient support, equipment and administrative services. Facilities demonstrated the ability to retain patients alive and on treatment at these costs, although outcomes for established patients (2-8% annual loss to follow-up or death) were better than outcomes for new patients in their first year of ART (77-95% alive and on treatment). This study illustrated that the facility-level costs of ART are lower than previously understood in these five countries. While limitations must be considered, and costs will vary across countries, this suggests that expanded treatment coverage may be affordable. Further research is needed to understand investment costs of treatment scale-up, non-facility costs and opportunities for more efficient resource allocation.

  19. Multi-Country Analysis of Treatment Costs for HIV/AIDS (MATCH): Facility-Level ART Unit Cost Analysis in Ethiopia, Malawi, Rwanda, South Africa and Zambia

    PubMed Central

    Tagar, Elya; Sundaram, Maaya; Condliffe, Kate; Matatiyo, Blackson; Chimbwandira, Frank; Chilima, Ben; Mwanamanga, Robert; Moyo, Crispin; Chitah, Bona Mukosha; Nyemazi, Jean Pierre; Assefa, Yibeltal; Pillay, Yogan; Mayer, Sam; Shear, Lauren; Dain, Mary; Hurley, Raphael; Kumar, Ritu; McCarthy, Thomas; Batra, Parul; Gwinnell, Dan; Diamond, Samantha; Over, Mead

    2014-01-01

    Background Today's uncertain HIV funding landscape threatens to slow progress towards treatment goals. Understanding the costs of antiretroviral therapy (ART) will be essential for governments to make informed policy decisions about the pace of scale-up under the 2013 WHO HIV Treatment Guidelines, which increase the number of people eligible for treatment from 17.6 million to 28.6 million. The study presented here is one of the largest of its kind and the first to describe the facility-level cost of ART in a random sample of facilities in Ethiopia, Malawi, Rwanda, South Africa and Zambia. Methods & Findings In 2010–2011, comprehensive data on one year of facility-level ART costs and patient outcomes were collected from 161 facilities, selected using stratified random sampling. Overall, facility-level ART costs were significantly lower than expected in four of the five countries, with a simple average of $208 per patient-year (ppy) across Ethiopia, Malawi, Rwanda and Zambia. Costs were higher in South Africa, at $682 ppy. This included medications, laboratory services, direct and indirect personnel, patient support, equipment and administrative services. Facilities demonstrated the ability to retain patients alive and on treatment at these costs, although outcomes for established patients (2–8% annual loss to follow-up or death) were better than outcomes for new patients in their first year of ART (77–95% alive and on treatment). Conclusions This study illustrated that the facility-level costs of ART are lower than previously understood in these five countries. While limitations must be considered, and costs will vary across countries, this suggests that expanded treatment coverage may be affordable. Further research is needed to understand investment costs of treatment scale-up, non-facility costs and opportunities for more efficient resource allocation. PMID:25389777

  20. Dental Treatment in a State-Funded Primary Dental Care Facility: Contextual and Individual Predictors of Treatment Need?

    PubMed

    Wanyonyi, Kristina L; Radford, David R; Gallagher, Jennifer E

    2017-01-01

    This study examined individual and contextual factors which predict the dental care received by patients in a state-funded primary dental care training facility in England. Routine clinical and demographic data were extracted from a live dental patient management system in a state-funded facility using novel methods. The data, spanning a four-year period [2008-2012] were cleaned, validated, linked by means of postcode to deprivation status, and analysed to identify factors which predict dental treatment need. The predictive relationship between patients' individual characteristics (demography, smoking, payment status) and contextual experience (deprivation based on area of residence), with common dental treatments received was examined using unadjusted analysis and adjusted logistic regression. Additionally, multilevel modelling was used to establish the isolated influence of area of residence on treatments. Data on 6,351 dental patients extracted comprised of 147,417 treatment procedures delivered across 10,371 courses of care. Individual level factors associated with the treatments were age, sex, payment exemption and smoking status and deprivation associated with area of residence was a contextual predictor of treatment. More than 50% of children (<18 years) and older adults (≥65 years) received preventive care in the form of 'instruction and advice', compared with 46% of working age adults (18-64 years); p = 0.001. The odds of receiving treatment increased with each increasing year of age amongst adults (p = 0.001): 'partial dentures' (7%); 'scale and polish' (3.7%); 'tooth extraction' (3%; p = 0.001), and 'instruction and advice' (3%; p = 0.001). Smokers had a higher likelihood of receiving all treatments; and were notably over four times more likely to receive 'instruction and advice' than non-smokers (OR 4.124; 95% CI: 3.088-5.508; p = 0.01). A further new finding from the multilevel models was a significant difference in treatment related to area of

  1. Dental Treatment in a State-Funded Primary Dental Care Facility: Contextual and Individual Predictors of Treatment Need?

    PubMed Central

    Radford, David R.; Gallagher, Jennifer E.

    2017-01-01

    Objective This study examined individual and contextual factors which predict the dental care received by patients in a state-funded primary dental care training facility in England. Methods Routine clinical and demographic data were extracted from a live dental patient management system in a state-funded facility using novel methods. The data, spanning a four-year period [2008–2012] were cleaned, validated, linked by means of postcode to deprivation status, and analysed to identify factors which predict dental treatment need. The predictive relationship between patients’ individual characteristics (demography, smoking, payment status) and contextual experience (deprivation based on area of residence), with common dental treatments received was examined using unadjusted analysis and adjusted logistic regression. Additionally, multilevel modelling was used to establish the isolated influence of area of residence on treatments. Results Data on 6,351 dental patients extracted comprised of 147,417 treatment procedures delivered across 10,371 courses of care. Individual level factors associated with the treatments were age, sex, payment exemption and smoking status and deprivation associated with area of residence was a contextual predictor of treatment. More than 50% of children (<18 years) and older adults (≥65 years) received preventive care in the form of ‘instruction and advice’, compared with 46% of working age adults (18–64 years); p = 0.001. The odds of receiving treatment increased with each increasing year of age amongst adults (p = 0.001): ‘partial dentures’ (7%); ‘scale and polish’ (3.7%); ‘tooth extraction’ (3%; p = 0.001), and ‘instruction and advice’ (3%; p = 0.001). Smokers had a higher likelihood of receiving all treatments; and were notably over four times more likely to receive ‘instruction and advice’ than non-smokers (OR 4.124; 95% CI: 3.088–5.508; p = 0.01). A further new finding from the multilevel models was a

  2. Application of a Bimetallic Treatment System (BTS) for PCB Removal from Older Structures on DoD Facilities. Cost and Performance Report

    DTIC Science & Technology

    2011-11-01

    Bimetallic Treatment System (BTS) for PCB Removal from Older Structures on DoD Facilities By Thomas Krug and Suzanne O’Hara, Geosyntec...COST AND PERFORMANCE REPORT FOR: Application of a Bimetallic Treatment System (BTS) for PCB Removal from Older Structures on DOD Facilities...11 3.4 Reduction in PCB concentrations in treated paint to less

  3. Influences on the start, selection and duration of treatment with antibiotics in long-term care facilities

    PubMed Central

    Daneman, Nick; Campitelli, Michael A.; Giannakeas, Vasily; Morris, Andrew M.; Bell, Chaim M.; Maxwell, Colleen J.; Jeffs, Lianne; Austin, Peter C.; Bronskill, Susan E.

    2017-01-01

    BACKGROUND: Understanding the extent to which current antibiotic prescribing behaviour is influenced by clinicians’ historical patterns of practice will help target interventions to optimize antibiotic use in long-term care. Our objective was to evaluate whether clinicians’ historical prescribing behaviours influence the start, prolongation and class selection for treatment with antibiotics in residents of long-term care facilities. METHODS: We conducted a retrospective cohort study of all physicians who prescribed to residents in long-term care facilities in Ontario between Jan. 1 and Dec. 31, 2014. We examined variability in antibiotic prescribing among physicians for 3 measures: start of treatment with antibiotics, use of prolonged durations exceeding 7 days and selection of fluoroquinolones. Funnel plots with control limits were used to determine the extent of variation and characterize physicians as extreme low, low, average, high and extreme high prescribers for each tendency. Multivariable logistic regression was used to assess whether a clinician’s prescribing tendency in the previous year predicted current prescribing patterns, after accounting for residents’ demographics, comorbidity, functional status and indwelling devices. RESULTS: Among 1695 long-term care physicians, who prescribed for 93 132 residents, there was wide variability in the start of antibiotic treatment (median 45% of patients, interquartile range [IQR] 32%–55%), use of prolonged treatment durations (median 30% of antibiotic prescriptions, IQR 19%–46%) and selection of fluoroquinolones (median 27% of antibiotic prescriptions, IQR 18%–37%). Prescribing tendencies for antibiotics by physicians in 2014 correlated strongly with tendencies in the previous year. After controlling for individual resident characteristics, prior prescribing tendency was a significant predictor of current practice. INTERPRETATION: Physicians prescribing antibiotics exhibited individual, measurable

  4. Influences on the start, selection and duration of treatment with antibiotics in long-term care facilities.

    PubMed

    Daneman, Nick; Campitelli, Michael A; Giannakeas, Vasily; Morris, Andrew M; Bell, Chaim M; Maxwell, Colleen J; Jeffs, Lianne; Austin, Peter C; Bronskill, Susan E

    2017-06-26

    Understanding the extent to which current antibiotic prescribing behaviour is influenced by clinicians' historical patterns of practice will help target interventions to optimize antibiotic use in long-term care. Our objective was to evaluate whether clinicians' historical prescribing behaviours influence the start, prolongation and class selection for treatment with antibiotics in residents of long-term care facilities. We conducted a retrospective cohort study of all physicians who prescribed to residents in long-term care facilities in Ontario between Jan. 1 and Dec. 31, 2014. We examined variability in antibiotic prescribing among physicians for 3 measures: start of treatment with antibiotics, use of prolonged durations exceeding 7 days and selection of fluoroquinolones. Funnel plots with control limits were used to determine the extent of variation and characterize physicians as extreme low, low, average, high and extreme high prescribers for each tendency. Multivariable logistic regression was used to assess whether a clinician's prescribing tendency in the previous year predicted current prescribing patterns, after accounting for residents' demographics, comorbidity, functional status and indwelling devices. Among 1695 long-term care physicians, who prescribed for 93 132 residents, there was wide variability in the start of antibiotic treatment (median 45% of patients, interquartile range [IQR] 32%-55%), use of prolonged treatment durations (median 30% of antibiotic prescriptions, IQR 19%-46%) and selection of fluoroquinolones (median 27% of antibiotic prescriptions, IQR 18%-37%). Prescribing tendencies for antibiotics by physicians in 2014 correlated strongly with tendencies in the previous year. After controlling for individual resident characteristics, prior prescribing tendency was a significant predictor of current practice. Physicians prescribing antibiotics exhibited individual, measurable and historical tendencies toward start of antibiotic treatment

  5. Measuring the Efficient Utilization of Medical Personnel at Navy Military Treatment Facilities

    DTIC Science & Technology

    1990-06-01

    measures of effectiveness (MOE) for utilizing manpower at a medical treatment facility by analyzing data from Navy hospitals. The MOE will be able to...at Navy facili- ties will be used to compare alternative MOEs., The data resources are categorized into expenditures, Naval health-care statistics ...of years., At the Office of the Chief of Naval Operations, OP-801 maintains financial data of medical budgets, 2. NAVAL HEALTH-CARE STATISTICS The

  6. Cost and cost-effectiveness of community based and health facility based directly observed treatment of tuberculosis in Dar es Salaam, Tanzania

    PubMed Central

    Wandwalo, Eliud; Robberstad, Bjarne; Morkve, Odd

    2005-01-01

    Background Identifying new approaches to tuberculosis treatment that are effective and put less demand to meagre health resources is important. One such approach is community based direct observed treatment (DOT). The purpose of the study was to determine the cost and cost effectiveness of health facility and community based directly observed treatment of tuberculosis in an urban setting in Tanzania. Methods Two alternative strategies were compared: health facility based directly observed treatment by health personnel and community based directly observed treatment by treatment supervisors. Costs were analysed from the perspective of health services, patients and community in the year 2002 in US $ using standard methods. Treatment outcomes were obtained from a randomised-controlled trial which was conducted alongside the cost study. Smear positive, smear negative and extra-pulmonary TB patients were included. Cost-effectiveness was calculated as the cost per patient successfully treated. Results The total cost of treating a patient with conventional health facility based DOT and community based DOT were $ 145 and $ 94 respectively. Community based DOT reduced cost by 35%. Cost fell by 27% for health services and 72% for patients. When smear positive and smear negative patients were considered separately, community DOT was associated with 45% and 19% reduction of the costs respectively. Patients used about $ 43 to follow their medication to health facility which is equivalent to their monthly income. Indirect costs were as important as direct costs, contributing to about 49% of the total patient's cost. The main reason for reduced cost was fewer number of visits to the TB clinic. Community based DOT was more cost-effective at $ 128 per patient successfully treated compared to $ 203 for a patient successfully treated with health facility based DOT. Conclusion Community based DOT presents an economically attractive option to complement health facility based DOT. This

  7. STS-79 landing views

    NASA Image and Video Library

    1996-09-26

    STS079-S-021 (26 Sept. 1996) --- The drag chute on the space shuttle Atlantis is fully deployed as the orbiter rolls down Runway 15 at the Shuttle Landing Facility (SLF) at the Kennedy Space Center (KSC), bringing an end to the successful ten-day mission. Landing occurred at 8:13:15 a.m. (EDT), Sept. 26, 1996. The touchdown marked the end of 188 days in space for astronaut Shannon W. Lucid, following her in-space exchange with astronaut John E. Blaha, who is now aboard Russia's Mir Space Station. Returning along with Lucid were her STS-79 crew mates - astronauts William F. Readdy, commander; Terrence W. Wilcutt, pilot; and Thomas D. Akers, Jerome (Jay) Apt and Carl E. Walz, mission specialists.

  8. Uncertainties of stormwater characteristics and removal rates of stormwater treatment facilities: implications for stormwater handling.

    PubMed

    Langeveld, J G; Liefting, H J; Boogaard, F C

    2012-12-15

    Stormwater runoff is a major contributor to the pollution of receiving waters. This study focuses at characterising stormwater in order to be able to determine the impact of stormwater on receiving waters and to be able to select the most appropriate stormwater handling strategy. The stormwater characterisation is based on determining site mean concentrations (SMCs) and their uncertainties as well as the treatability of stormwater by monitoring specific pollutants concentration levels (TSS, COD, BOD, TKN, TP, Pb, Cu, Zn, E.coli) at three full scale stormwater treatment facilities in Arnhem, the Netherlands. This has resulted in 106 storm events being monitored at the lamella settler, 59 at the high rate sand filter and 132 at the soil filter during the 2 year monitoring period. The stormwater characteristics in Arnhem in terms of SMCs for main pollutants TSS and COD and settling velocities differ from international data. This implies that decisions for stormwater handling made on international literature data will very likely be wrong due to assuming too high concentrations of pollutants and misjudgement of the treatability of stormwater. The removal rates monitored at the full scale treatment facilities are within the expected range, with the soil filter and the sand filter having higher removal rates than the lamella settler. The full scale pilots revealed the importance of incorporating gross solids removal in the design of stormwater treatment facilities, as the gross solids determine operation and maintenance requirements. Copyright © 2012 Elsevier Ltd. All rights reserved.

  9. Estimation and comparision of curve numbers based on dynamic land use land cover change, observed rainfall-runoff data and land slope

    NASA Astrophysics Data System (ADS)

    Deshmukh, Dhananjay Suresh; Chaube, Umesh Chandra; Ekube Hailu, Ambaye; Aberra Gudeta, Dida; Tegene Kassa, Melaku

    2013-06-01

    The CN represents runoff potential is estimated using three different methods for three watersheds namely Barureva, Sher and Umar watershed located in Narmada basin. Among three watersheds, Sher watershed has gauging site for the runoff measurements. The CN computed from the observed rainfall-runoff events is termed as CN(PQ), land use and land cover (LULC) is termed as CN(LU) and the CN based on land slope is termed as SACN2. The estimated annual CN(PQ) varies from 69 to 87 over the 26 years data period with median 74 and average 75. The range of CN(PQ) from 70 to 79 are most significant values and these truly represent the AMC II condition for the Sher watershed. The annual CN(LU) was computed for all three watersheds using GIS and the years are 1973, 1989 and 2000. Satellite imagery of MSS, TM and ETM+ sensors are available for these years and obtained from the Global Land Cover Facility Data Center of Maryland University USA. The computed CN(LU) values show rising trend with the time and this trend is attributed to expansion of agriculture area in all watersheds. The predicted values of CN(LU) with time (year) can be used to predict runoff potential under the effect of change in LULC. Comparison of CN(LU) and CN(PQ) values shows close agreement and it also validates the classification of LULC. The estimation of slope adjusted SA-CN2 shows the significant difference over conventional CN for the hilly forest lands. For the micro watershed planning, SCS-CN method should be modified to incorporate the effect of change in land use and land cover along with effect of land slope.

  10. PROCESS DESIGN MANUAL: LAND APPLICATION OF ...

    EPA Pesticide Factsheets

    Land application of sewage sludge generated by domestic sewage treatment is performed in an environmentally safe and cost–effective manner in many communities. Land application involves taking advantage of the fertilizing and soil conditioning properties of sewage sludge by spreading the sewage sludge on the soil surface, incorporating or injecting the sewage sludge into soil, or spraying the sewage sludge. Because sewage sludge disposal practices (e.g., landfilling) are becoming less available and more costly, and because of the increasing desire to beneficially reuse waste residuals whenever possible, land application is increasingly chosen as a sewage sludge use or disposal practice. Approximately 33 percent of the 5.4 million dry metric tons of sewage sludge generated annually in the United States at publicly owned treatment works (POTWs) is land applied. Of the sewage sludge that is land applied, approximately 67% is land applied on agricultural lands, 3% on forest lands, approximately 9% on reclamation sites, and 9% on public contact sites; 12% is sold or given away in a bag or other container for application to the land (Federal Register, Vol. 58, No. 32, February 19, 1993). In addition, approximately 8.6 billion gallons of domestic septage is generated annually. Land application of sewage sludge has been practiced in many countries for centuries so that the nutrients (e.g., nitrogen, phosphorus) and organic matter in sewage sludge can be beneficia

  11. Implications of changing national policies on land use in the Chittagong Hill Tracts of Bangladesh.

    PubMed

    Thapa, Gopal B; Rasul, Golam

    2006-12-01

    Land use in the Chittagong Hill Tracts (CHT) of Bangladesh had undergone changes over the past several centuries. The landscape, which was mostly covered with forest with interspersed shifting cultivation plots until the beginning of the colonial period, has gradually changed into a landscape with a blend of land uses. Overall, the forest area has gradually declined, while the area under shifting cultivation and sedentary agriculture has expanded. The process of the change was multi-directional. National forestry, land use, land taxation, population migration policies, and development activities, such as construction of a hydroelectric dam and roads, played an important role in this process. Shifting cultivation had inflicted little damage on the forest until the beginning of the colonial period. The pace of deforestation accelerated with the nationalization of forests which abolished tribal people's customary use and management rights to the forest, and allowed large-scale commercial logging both legally and illegally. The pace was further intensified by the policy encouraging population migration to CHT and construction of a reservoir on the Karnafuli River. Efforts were made to replace shifting cultivation with more productive types of sedentary agriculture. However, much change could not take place in the absence of secure land rights, supportive trade policies, and the required support services and facilities, including infrastructure. Locationally suitable land use evolved in areas where transportation facilities were available and farmers were granted land title with the necessary extension services and credit facilities. These findings have important policy implications for the promotion of environmentally and economically sound land use in CHT.

  12. Influence of thermal hydrolysis-anaerobic digestion treatment of wastewater solids on concentrations of Triclosan, Triclocarban, and their transformation products in biosolids

    USDA-ARS?s Scientific Manuscript database

    The growing concern worldwide regarding the presence of emerging contaminants in biosolids calls for a better understanding of how different treatment technologies at water resource recovery facilities (WRRFs) can influence concentrations prior to biosolids land application. This study focuses on t...

  13. Hydroelectric Generating Facilities General Permit ...

    EPA Pesticide Factsheets

    2017-08-28

    The Notice of Availability of the Final NPDES General Permits (HYDROGP) for Discharges at Hydroelectric Generating Facilities in Massachusetts (MAG360000) and New Hampshire (NHG360000) and Tribal Lands in the State of Massachusetts was published in the Federal Register on December 7, 2009 (see 74 Fed. Reg. No. 233, pages 64074 - 64075).

  14. Land management policy and program trends

    Treesearch

    Darrell E. Lewis

    1980-01-01

    There has been a shift in federal land management agencies toward less facility-oriented recreational activities. This shift is described by executive messages and legislation. Other indicators of the shift are President Carter's environmental message of 1979, establishment of additional National Recreation Trails, and a combined report to the President by the...

  15. Patient Scenarios Illustrating Benefits of Automation in DoD Medical Treatment Facilities.

    DTIC Science & Technology

    1981-10-23

    d-ntif by block nmber) This report outlines the difference that automation may make in patient encounters within the military health care system. Two...automation may make in patient encounters with the military health care system, as part of a task to characterize the benefit set of automation in...FI-RI4 323 PATIENT SCENARIOS ILLUSTRATING BENEFITS OF AUTOM ATION 1/1 IDOD MEDICAL TREATMENT FACILITIES(U) LITTLE (ARTHUR D) INC CAMBRIDGE MR

  16. Report: transboundary hazardous waste management. part II: performance auditing of treatment facilities in importing countries.

    PubMed

    Chang, Tien-Chin; Ni, Shih-Piao; Fan, Kuo-Shuh; Lee, Ching-Hwa

    2006-06-01

    Before implementing the self-monitoring model programme of the Basel Convention in the Asia, Taiwan has conducted a comprehensive 4-year follow-up project to visit the governmental authorities and waste-disposal facilities in the countries that import waste from Taiwan. A total of nine treatment facilities, six of which are reported in this paper, and the five countries where the plants are located were visited in 2001-2002. France, Belgium and Finland primarily handled polychlorinated biphenyl capacitors, steel mill dust and metal waste. The United States accepted metal sludge, mainly electroplating sludge, from Taiwan. Waste printed circuit boards, waste wires and cables, and a mixture of waste metals and electronics were the major items exported to China. Relatively speaking, most treatment plants for hazardous waste paid close attention to environmental management, such as pollution control and monitoring, site zoning, system management regarding occupational safety and hygiene, data management, permits application, and image promotion. Under the tight restrictions formulated by the central environment agency, waste treatment plants in China managed the environmental issues seriously. For example, one of the treatment plants had ISO 14001 certification. It is believed that with continuous implementation of regulations, more improvement is foreseeable. Meanwhile, Taiwan and China should also continuously enhance their collaboration regarding the transboundary management of hazardous waste.

  17. ENGINEERING STUDY FOR THE 200 AREA EFFLUENT TREATMENT FACILITY (ETF) SECONDARY WASTE TREATMENT OF PROJECTED FUTURE WASTE FEEDS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    LUECK, K.J.

    2004-10-18

    This report documents an engineering study conducted to evaluate alternatives for treating secondary waste in the secondary treatment train (STT) of the Hanford Site 200 Area Effluent Treatment Facility (ETF). The study evaluates ETF STT treatment alternatives and recommends preferred alternatives for meeting the projected future missions of the ETF. The preferred alternative(s) will process projected future ETF influents to produce a solid waste acceptable for final disposal on the Hanford Site. The main text of this report summarizes the ETF past and projected operations, lists the assumptions about projected operations that provide the basis for the engineering evaluation, andmore » summarizes the evaluation process. The evaluation process includes identification of available modifications to the current ETF process, screens those modifications for technical viability, evaluates the technically viable alternatives, and provides conclusions and recommendations based on that evaluation.« less

  18. Women's Land Tenure Security and Household Human Capital: Evidence from Ethiopia's Land Certification.

    PubMed

    Muchomba, Felix M

    2017-10-01

    This paper examines the impact of Ethiopia's gendered land certification programs on household consumption of healthcare, food, education, and clothing. Ethiopia embarked on a land tenure reform program in 1998, after years of communism during which all land was nationalized. The reform began in Tigray region where land certificates were issued to household heads, who were primarily male. In a second phase carried out in 2003-2005, three other regions issued land certificates jointly to household heads and spouses, presenting variation in land tenure security by gender. Results using household panel data show that joint land certification to spouses was accompanied by increased household consumption of healthcare and homegrown food and decreased education expenditure, compared to household-head land certification. Joint land certification was also accompanied by increased consumption of women's and girls' clothing, and decreased men's clothing expenditures indicating results may be explained by a shift in the gender balance of power within households. Analysis on the incidence and duration of illness indicates that increased healthcare expenditures after joint land certification may be due to joint certification households seeking more effective treatment than head-only certification households for household members who fell ill or suffered injuries.

  19. Instrumental Landing Using Audio Indication

    NASA Astrophysics Data System (ADS)

    Burlak, E. A.; Nabatchikov, A. M.; Korsun, O. N.

    2018-02-01

    The paper proposes an audio indication method for presenting to a pilot the information regarding the relative positions of an aircraft in the tasks of precision piloting. The implementation of the method is presented, the use of such parameters of audio signal as loudness, frequency and modulation are discussed. To confirm the operability of the audio indication channel the experiments using modern aircraft simulation facility were carried out. The simulated performed the instrument landing using the proposed audio method to indicate the aircraft deviations in relation to the slide path. The results proved compatible with the simulated instrumental landings using the traditional glidescope pointers. It inspires to develop the method in order to solve other precision piloting tasks.

  20. Race/Ethnic Disparities in the Utilization of Treatment for Drug Dependent Inmates in U.S. State Correctional Facilities

    PubMed Central

    Nowotny, Kathryn M.

    2014-01-01

    This study examines race/ethnic disparities in treatment for drug dependent inmates in state correctional facilities. The data come from the 2004 Survey of Inmates in State Correctional Facilities. Fixed effects logistic regression is used to analyze treatment outcomes for 5,180 inmates housed within 286 prisons. The analysis accounts for differences in background characteristics (i.e., age, gender, marital status, foreign born status, veteran status), socioeconomic characteristics (i.e., education, employment prior to incarceration), mental health (i.e., diagnosis with a serious mental illness), and incarceration experiences (i.e., current conviction, previous incarceration episodes, time served, additional sentencing requirements, external social support, disciplinary violations). The findings identify a remarkable unmet need among drug dependent inmates in that less than one-half of drug dependent inmates had received any type of treatment in prison at the time of the interview with the most common treatment type being self-help groups. Compared to whites, drug dependent Latino inmates have significantly lower odds of utilizing treatment, yet there are no significant black-white disparities found. Implications for drug treatment within prisons are discussed. PMID:25270722

  1. Antimicrobial Resistance Determinants in Acinetobacter baumannii Isolates Taken from Military Treatment Facilities

    PubMed Central

    Leski, Tomasz A.; Stockelman, Michael G.; Craft, David W.; Zurawski, Daniel V.; Kirkup, Benjamin C.; Vora, Gary J.

    2014-01-01

    Multidrug-resistant (MDR) Acinetobacter baumannii infections are of particular concern within medical treatment facilities, yet the gene assemblages that give rise to this phenotype remain poorly characterized. In this study, we tested 97 clinical A. baumannii isolates collected from military treatment facilities (MTFs) from 2003 to 2009 by using a molecular epidemiological approach that enabled for the simultaneous screening of 236 antimicrobial resistance genes. Overall, 80% of the isolates were found to be MDR, each strain harbored between one and 17 resistant determinants, and a total of 52 unique resistance determinants or gene families were detected which are known to confer resistance to β-lactam (e.g., blaGES-11, blaTEM, blaOXA-58), aminoglycoside (e.g., aphA1, aacC1, armA), macrolide (msrA, msrB), tetracycline [e.g., tet(A), tet(B), tet(39)], phenicol (e.g., cmlA4, catA1, cat4), quaternary amine (qacE, qacEΔ1), streptothricin (sat2), sulfonamide (sul1, sul2), and diaminopyrimidine (dfrA1, dfrA7, dfrA19) antimicrobial compounds. Importantly, 91% of the isolates harbored blaOXA-51-like carbapenemase genes (including six new variants), 40% harbored the blaOXA-23 carbapenemase gene, and 89% contained a variety of aminoglycoside resistance determinants with up to six unique determinants identified per strain. Many of the resistance determinants were found in potentially mobile gene cassettes; 45% and 7% of the isolates contained class 1 and class 2 integrons, respectively. Combined, the results demonstrate a facile approach that supports a more complete understanding of the genetic underpinnings of antimicrobial resistance to better assess the load, transmission, and evolution of MDR in MTF-associated A. baumannii. PMID:24247131

  2. 43 CFR 3276.10 - What are the reporting requirements for facility and lease operations involving Federal...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 43 Public Lands: Interior 2 2012-10-01 2012-10-01 false What are the reporting requirements for facility and lease operations involving Federal geothermal resources? 3276.10 Section 3276.10 Public Lands: Interior Regulations Relating to Public Lands (Continued) BUREAU OF LAND MANAGEMENT, DEPARTMENT OF THE INTERIOR MINERALS MANAGEMENT (3000)...

  3. 43 CFR 3276.10 - What are the reporting requirements for facility and lease operations involving Federal...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 43 Public Lands: Interior 2 2011-10-01 2011-10-01 false What are the reporting requirements for facility and lease operations involving Federal geothermal resources? 3276.10 Section 3276.10 Public Lands: Interior Regulations Relating to Public Lands (Continued) BUREAU OF LAND MANAGEMENT, DEPARTMENT OF THE INTERIOR MINERALS MANAGEMENT (3000)...

  4. 43 CFR 3276.10 - What are the reporting requirements for facility and lease operations involving Federal...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 43 Public Lands: Interior 2 2014-10-01 2014-10-01 false What are the reporting requirements for facility and lease operations involving Federal geothermal resources? 3276.10 Section 3276.10 Public Lands: Interior Regulations Relating to Public Lands (Continued) BUREAU OF LAND MANAGEMENT, DEPARTMENT OF THE INTERIOR MINERALS MANAGEMENT (3000)...

  5. 43 CFR 3276.10 - What are the reporting requirements for facility and lease operations involving Federal...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 43 Public Lands: Interior 2 2013-10-01 2013-10-01 false What are the reporting requirements for facility and lease operations involving Federal geothermal resources? 3276.10 Section 3276.10 Public Lands: Interior Regulations Relating to Public Lands (Continued) BUREAU OF LAND MANAGEMENT, DEPARTMENT OF THE INTERIOR MINERALS MANAGEMENT (3000)...

  6. STS-94 Columbia Landing at KSC (drag chute deploy)

    NASA Technical Reports Server (NTRS)

    1997-01-01

    The Space Shuttle orbiter Columbia touches down on Runway 33 at KSCs Shuttle Landing Facility at 6:46:34 a.m. EDT with Mission Commander James D. Halsell Jr. and Pilot Susan L. Still at the controls to complete the STS-94 mission. Also on board are Mission Specialist Donald A. Thomas, Mission Specialist Michael L. Gernhardt, Payload Commander Janice Voss, and Payload Specialists Roger K. Crouch and Gregory T. Linteris. During the Microgravity Science Laboratory-1 (MSL-1) mission, the Spacelab module was used to test some of the hardware, facilities and procedures that are planned for use on the International Space Station while the flight crew conducted combustion, protein crystal growth and materials processing experiments. This mission was a reflight of the STS-83 mission that lifted off from KSC in April of this year. That space flight was cut short due to indications of a faulty fuel cell. This was Columbias 11th landing at KSC and the 38th landing at the space center in the history of the Shuttle program.

  7. Landing of STS-63 Discovery at KSC

    NASA Technical Reports Server (NTRS)

    1995-01-01

    Contrails stream from the port side wing of the Space Shuttle Discovery as it touches down on Runway 15 at the Kennedy Space Center's (KSC) Shuttle Landing Facility to complete an eight day mission. Touchdown occurred at 6:50:19 a.m. (EST), February 11, 1995.

  8. 32 CFR 644.424 - Development of public port or industrial facilities.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... industrial facilities upon the available land shall file a written application with the District Engineer... development of public port or industrial facilities, the District Engineer shall give notice of such... 32 National Defense 4 2011-07-01 2011-07-01 false Development of public port or industrial...

  9. 32 CFR 644.424 - Development of public port or industrial facilities.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... industrial facilities upon the available land shall file a written application with the District Engineer... development of public port or industrial facilities, the District Engineer shall give notice of such... 32 National Defense 4 2010-07-01 2010-07-01 true Development of public port or industrial...

  10. Solid-phase microextraction of organophosphate pesticides in source waters for drinking water treatment facilities.

    PubMed

    Flynt, Elizabeth; Dupuy, Aubry; Kennedy, Charles; Bennett, Shanda

    2006-09-01

    The rapid detection of contaminants in our nation's drinking water has become a top homeland security priority in this time of increased national vigilance. Real-time monitoring of drinking water for deliberate or accidental contamination is key to national security. One method that can be employed for the rapid screening of pollutants in water is solid-phase microextraction (SPME). SPME is a rapid, sensitive, solvent-free system that can be used to screen for contaminants that have been accidentally or intentionally introduced into a water system. A method using SPME has been developed and optimized for the detection of seven organophosphate pesticides in drinking water treatment facility source waters. The method is tested in source waters for drinking water treatment facilities in Mississippi and Alabama. Water is collected from a deepwater well at Stennis Space Center (SSC), MS, the drinking water source for SSC, and from the Converse Reservoir, the main drinking water supply for Mobile, AL. Also tested are samples of water collected from the Mobile Alabama Water and Sewer System drinking water treatment plant prior to chlorination. The method limits of detection for the seven organophosphates were comparable to those described in several Environmental Protection Agency standard methods. They range from 0.25 to 0.94 microg/L.

  11. Satellite land use acquisition and applications to hydrologic planning models

    NASA Technical Reports Server (NTRS)

    Algazi, V. R.; Suk, M.

    1977-01-01

    A developing operational procedure for use by the Corps of Engineers in the acquisition of land use information for hydrologic planning purposes was described. The operational conditions preclude the use of dedicated, interactive image processing facilities. Given the constraints, an approach to land use classification based on clustering seems promising and was explored in detail. The procedure is outlined and examples of application to two watersheds given.

  12. STS-38 Atlantis, Orbiter Vehicle (OV) 104, lands on runway 33 at KSC SLF

    NASA Image and Video Library

    1990-11-20

    STS038-S-041 (20 Nov 1990) --- STS-38 Atlantis, Orbiter Vehicle (OV) 104, lands on runway 33 at Kennedy Space Center (KSC) Shuttle Landing Facility (SLF). The main landing gear (MLG) has just touched down on the runway surface as the nose landing gear (NLG) glides above it. The Department of Defense (DOD)-devoted mission came to an end (with complete wheel stop) at 4:43:37 pm (Eastern Standard Time (EST)).

  13. The Addiction Treatment Unit: a dual diagnosis program at the California Medical Facility--a descriptive report.

    PubMed

    Katz, R I

    1999-01-01

    The Addiction Treatment Unit is a dual diagnosis program which exists in the California Department of Corrections. It is housed in the California Medical Facility in Vacaville, California. Program residents must meet the diagnostic criteria of having a major mental disorder substantiated by a DSM-IV Axis I diagnosis and also meet the criteria for a substance abuse/dependence disorder. All patients are housed in one wing of the facility, which is based on the format of a modified therapeutic community and focuses on the concept of recovery. A multidisciplinary treatment team comprised of a psychiatrist, a psychologist, a social worker and a psychiatric technician delivers clinical interventions, including individual and group therapy as well as medication management. The focus of the drug treatment aspect is an Alcoholics Anonymous/Narcotics Anonymous approach based on 12-Step philosophy. Research involving other therapeutic communities running in prisons is discussed as is the aspect of dual diagnosis programs. Logistical and environmental constraints which pose challenges to running the Addiction Treatment Unit are considered. A summary section reflects on aspects which have been successful, what has not worked or has been changed and upcoming program revisions.

  14. Exposure to airborne fungi during sorting of recyclable plastics in waste treatment facilities.

    PubMed

    Černá, Kristýna; Wittlingerová, Zdeňka; Zimová, Magdaléna; Janovský, Zdeněk

    2017-02-28

    In working environment of waste treatment facilities, employees are exposed to high concentrations of airborne microorganisms. Fungi constitute an essential part of them. This study aims at evaluating the diurnal variation in concentrations and species composition of the fungal contamination in 2 plastic waste sorting facilities in different seasons. Air samples from the 2 sorting facilities were collected through the membrane filters method on 4 different types of cultivation media. Isolated fungi were classified to genera or species by using a light microscopy. Overall, the highest concentrations of airborne fungi were recorded in summer (9.1×103-9.0×105 colony-forming units (CFU)/m3), while the lowest ones in winter (2.7×103-2.9×105 CFU/m3). The concentration increased from the beginning of the work shift and reached a plateau after 6-7 h of the sorting. The most frequently isolated airborne fungi were those of the genera Penicillium and Aspergillus. The turnover of fungal species between seasons was relatively high as well as changes in the number of detected species, but potentially toxigenic and allergenic fungi were detected in both facilities during all seasons. Generally, high concentrations of airborne fungi were detected in the working environment of plastic waste sorting facilities, which raises the question of health risk taken by the employees. Based on our results, the use of protective equipment by employees is recommended and preventive measures should be introduced into the working environment of waste sorting facilities to reduce health risk for employees. Med Pr 2017;68(1):1-9. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  15. 49 CFR 1155.26 - Transfer and termination of a land-use-exemption permit.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 8 2010-10-01 2010-10-01 false Transfer and termination of a land-use-exemption permit. 1155.26 Section 1155.26 Transportation Other Regulations Relating to Transportation (Continued... FACILITIES Procedures Governing Applications for a Land-Use-Exemption Permit § 1155.26 Transfer and...

  16. Modeling Soil Moisture in Support of the Revegetation of Military Lands in Arid Regions.

    NASA Astrophysics Data System (ADS)

    Caldwell, T. G.; McDonald, E. V.; Young, M. H.

    2003-12-01

    The National Training Center (NTC), the Army's primary mechanized maneuver training facility, covers approximately 2600 km2 within the Mojave Desert in southern California, and is the subject of ongoing studies to support the sustainability of military lands in desert environments. Revegetation of these lands by the Integrated Training Areas Management (ITAM) Program requires the identification of optimum growing conditions to reestablish desert vegetation from seed and seedling, especially with regard to the timing and abundance of plant-available water. Water content, soil water potential, and soil temperature were continuously monitored and used to calibrate the Simultaneous Heat And Water (SHAW) model at 3 re-seeded sites. Modeled irrigation scenarios were used to further evaluate the most effective volume, frequency, and timing of irrigation required to maximize revegetation success and minimize water use. Surface treatments including straw mulch, gravel mulch, soil tackifier and plastic sheet

  17. 43 CFR 3272.11 - How do I describe the proposed utilization facility?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...) BUREAU OF LAND MANAGEMENT, DEPARTMENT OF THE INTERIOR MINERALS MANAGEMENT (3000) GEOTHERMAL RESOURCE... proposed facility operations, including estimated total production and injection rates; estimated well flow... site(s); (e) The source, quality, and proposed consumption rate of water to be used during facility...

  18. Patient satisfaction on tuberculosis treatment service and adherence to treatment in public health facilities of Sidama zone, South Ethiopia.

    PubMed

    Nezenega, Zekariyas Sahile; Gacho, Yohannes H Michael; Tafere, Tadese Ejigu

    2013-03-22

    Patient compliance is a key factor in treatment success. Satisfied patients are more likely to utilize health services, comply with medical treatment, and continue with the health care providers. Yet, the national tuberculosis control program failed to address some of these aspects in order to achieve the national targets. Hence, this study attempted to investigate patient satisfaction and adherence to tuberculosis treatment in Sidama zone of south Ethiopia. A facility based cross sectional study was conducted using quantitative method of data collection from March to April 2011. A sample of 531 respondents on anti TB treatment from 11 health centers and 1 hospital were included in the study. The sample size to each facility was allocated using probability proportional to size allocation, and study participants for the interview were selected by systematic random sampling. A Pre tested, interviewer administered questionnaire was used to collect the data. Collected data was edited, coded and entered to Epi data version 3.1 and exported to SPSS version 16. Confirmatory factor analysis was done to identify factors that explain most of the variance observed in most of the manifested variables. Bivariate and Multivariate analysis were computed to analyze the data. The study revealed 90% of the study participants were satisfied with TB treatment service. However, 26% of respondents had poor adherence to their TB treatment. Patient perceived on professional care, time spent with health care provider, accessibility, technical competency, convenience (cleanliness) and consultation and relational empathy were independent predictors of overall patient satisfaction (P < 0.05). In addition to this, perceived waiting time was significantly associated with patient satisfaction (Beta = 0.262). In multivariate analysis occupational status, area of residence, perceived time spent with health care provider, perceived accessibility, perceived waiting time, perceived professional care

  19. 75 FR 77954 - Transfer of Federally Assisted Facility

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-14

    ... of Charlottesville (City) intends to transfer a facility and land located at 315 4th Street, NW... parcel, and is located at 315 4th Street, NW., in Charlottesville, Virginia. The building is within an...

  20. Recreation users fees on federal lands: a test of structural change between 1995 and 2003

    Treesearch

    J.M. Bowker; Gary Green; Dan MuCullom; Ken Cordell

    2008-01-01

    Federal lands provide many recreation facilities and services. On some of these lands, fees have been and are currently being charged for certain recreational services. This study examined the attitudes of users, between 1995 and 2003, towards recreation user fees on public lands. Data from the National Survey on Recreation and the Environment on recreational...

  1. Advances in land modeling of KIAPS based on the Noah Land Surface Model

    NASA Astrophysics Data System (ADS)

    Koo, Myung-Seo; Baek, Sunghye; Seol, Kyung-Hee; Cho, Kyoungmi

    2017-08-01

    As of 2013, the Noah Land Surface Model (LSM) version 2.7.1 was implemented in a new global model being developed at the Korea Institute of Atmospheric Prediction Systems (KIAPS). This land surface scheme is further refined in two aspects, by adding new physical processes and by updating surface input parameters. Thus, the treatment of glacier land, sea ice, and snow cover are addressed more realistically. Inconsistencies in the amount of absorbed solar flux at ground level by the land surface and radiative processes are rectified. In addition, new parameters are available by using 1-km land cover data, which had usually not been possible at a global scale. Land surface albedo/emissivity climatology is newly created using Moderate-Resolution Imaging Spectroradiometer (MODIS) satellitebased data and adjusted parameterization. These updates have been applied to the KIAPS-developed model and generally provide a positive impact on near-surface weather forecasting.

  2. Appraisal of ground-water quality near wastewater-treatment facilities, Glacier National Park, Montana

    USGS Publications Warehouse

    Moreland, Joe A.; Wood, Wayne A.

    1982-01-01

    Water-level and water-quality data were collected from monitoring wells at wastewater-treatment facilities in Glacier National Park. Five additional shallow observation wells were installed at the Glacier Park Headquarters facility to monitor water quality in the shallow ground-water system.Water-level, water-quality, and geologic information indicate that some of the initial monitoring wells are not ideally located to sample ground water most likely to be affected by waste disposal at the sites. Small differences in chemical characteristics between samples from monitor wells indicate that effluent may be affecting ground-water quality but that impacts are not significant.Future monitoring of ground-water quality could be limited to selected wells most likely to be impacted by percolating effluent. Laboratory analyses for common ions could detect future impacts.

  3. STS-96 Discovery night landing side view

    NASA Technical Reports Server (NTRS)

    1999-01-01

    Beneath a bright moon, the landing of Space Shuttle Discovery at KSC's Shuttle Landing Facility runway 15 is reflected in the nearby canal. This 47th Shuttle landing at KSC completes the 9- day, 19-hour, 13-minute and 1-second long STS-96 mission. It is the 94th flight in the Space Shuttle program, the 26th for Discovery, the 11th night landing, and the 18th consecutive landing in Florida. Main gear touchdown was at 2:02:43 EDT June 6 , landing on orbit 154 of the mission. Nose gear touchdown was at 2:02:59 a.m. EDT, and the wheels stopped at 2:03:39 a.m. EDT. At the controls were Commander Kent V. Rominger and Pilot Rick D. Husband. Also onboard the orbiter were Mission Specialists Ellen Ochoa (Ph.D.), Tamara E. Jernigan (Ph.D.), Daniel S. Barry (M.D., Ph.D.), Julie Payette and Valery Ivanovich Tokarev. Payette represents the Canadian Space Agency and Tokarev the Russian Space Agency. The crew returned from the second flight to the International Space Station on a logistics and resupply mission.

  4. STS-124 Space Shuttle Discovery Landing

    NASA Image and Video Library

    2008-06-14

    The aft end of the space shuttle Discovery is seen shortly after landing on runway 15 of the NASA Kennedy Space Center Shuttle Landing Facility at 11:15 a.m., Saturday, June 14, 2008 in Cape Canaveral, Florida. Onboard Discovery were NASA astronauts Mark Kelly, commander; Ken Ham, pilot; Mike Fossum, Ron Garan, Karen Nyberg, Garrett Reisman and Japan Aerospace Exploration Agency astronaut Akihiko Hoshide, all mission specialists. During the STS-124 mission, Discovery's crew installed the Japan Aerospace Exploration Agency's large Kibo laboratory and its remote manipulator system leaving a larger space station and one with increased science capabilities. Photo Credit: (NASA/Bill Ingalls)

  5. Impacts of historic and projected land-cover, land-use, and land-management change on carbon and water fluxes: The Land Use Model Intercomparison Project (LUMIP)

    NASA Astrophysics Data System (ADS)

    Lawrence, D. M.; Lombardozzi, D. L.; Lawrence, P.; Hurtt, G. C.

    2017-12-01

    Human land-use activities have resulted in large changes to the Earth surface, with resulting implications for climate. In the future, land-use activities are likely to intensify to meet growing demands for food, fiber, and energy. The Land Use Model Intercomparison Project (LUMIP) aims to further advance understanding of the broad question of impacts of land-use and land-cover change (LULCC) as well as more detailed science questions to get at process-level attribution, uncertainty, and data requirements in more depth and sophistication than possible in a multi-model context to date. LUMIP is multi-faceted and aims to advance our understanding of land-use change from several perspectives. In particular, LUMIP includes a factorial set of land-only simulations that differ from each other with respect to the specific treatment of land use or land management (e.g., irrigation active or not, crop fertilization active or not, wood harvest on or not), or in terms of prescribed climate. This factorial series of experiments serves several purposes and is designed to provide a detailed assessment of how the specification of land-cover change and land management affects the carbon, water, and energy cycle response to land-use change. The potential analyses that are possible through this set of experiments are vast. For example, comparing a control experiment with all land management active to an experiment with no irrigation allows a multi-model assessment of whether or not the increasing use of irrigation during the 20th century is likely to have significantly altered trends of regional water and energy fluxes (and therefore climate) and/or crop yield and carbon fluxes in agricultural regions. Here, we will present preliminary results from the factorial set of experiments utilizing the Community Land Model (CLM5). The analyses presented here will help guide multi-model analyses once the full set of LUMIP simulations are available.

  6. Apollo experience report: Real-time auxiliary computing facility development

    NASA Technical Reports Server (NTRS)

    Allday, C. E.

    1972-01-01

    The Apollo real time auxiliary computing function and facility were an extension of the facility used during the Gemini Program. The facility was expanded to include support of all areas of flight control, and computer programs were developed for mission and mission-simulation support. The scope of the function was expanded to include prime mission support functions in addition to engineering evaluations, and the facility became a mandatory mission support facility. The facility functioned as a full scale mission support activity until after the first manned lunar landing mission. After the Apollo 11 mission, the function and facility gradually reverted to a nonmandatory, offline, on-call operation because the real time program flexibility was increased and verified sufficiently to eliminate the need for redundant computations. The evaluation of the facility and function and recommendations for future programs are discussed in this report.

  7. An integrated prediction and optimization model of biogas production system at a wastewater treatment facility.

    PubMed

    Akbaş, Halil; Bilgen, Bilge; Turhan, Aykut Melih

    2015-11-01

    This study proposes an integrated prediction and optimization model by using multi-layer perceptron neural network and particle swarm optimization techniques. Three different objective functions are formulated. The first one is the maximization of methane percentage with single output. The second one is the maximization of biogas production with single output. The last one is the maximization of biogas quality and biogas production with two outputs. Methane percentage, carbon dioxide percentage, and other contents' percentage are used as the biogas quality criteria. Based on the formulated models and data from a wastewater treatment facility, optimal values of input variables and their corresponding maximum output values are found out for each model. It is expected that the application of the integrated prediction and optimization models increases the biogas production and biogas quality, and contributes to the quantity of electricity production at the wastewater treatment facility. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Modeling and Validation of a Navy A6-Intruder Actively Controlled Landing Gear System

    NASA Technical Reports Server (NTRS)

    Horta, Lucas G.; Daugherty, Robert H.; Martinson, Veloria J.

    1999-01-01

    Concepts for long-range air travel are characterized by airframe designs with long, slender, relatively flexible fuselages. One aspect often overlooked is ground-induced vibration of these aircraft. This paper presents an analytical and experimental study of reducing ground-induced aircraft vibration loads by using actively controlled landing gear. A facility has been developed to test various active landing gear control concepts and their performance, The facility uses a Navy A6 Intruder landing gear fitted with an auxiliary hydraulic supply electronically controlled by servo valves. An analytical model of the gear is presented, including modifications to actuate the gear externally, and test data are used to validate the model. The control design is described and closed-loop test and analysis comparisons are presented.

  9. Viirs Land Science Investigator-Led Processing System

    NASA Astrophysics Data System (ADS)

    Devadiga, S.; Mauoka, E.; Roman, M. O.; Wolfe, R. E.; Kalb, V.; Davidson, C. C.; Ye, G.

    2015-12-01

    The objective of the NASA's Suomi National Polar Orbiting Partnership (S-NPP) Land Science Investigator-led Processing System (Land SIPS), housed at the NASA Goddard Space Flight Center (GSFC), is to produce high quality land products from the Visible Infrared Imaging Radiometer Suite (VIIRS) to extend the Earth System Data Records (ESDRs) developed from NASA's heritage Earth Observing System (EOS) Moderate Resolution Imaging Spectroradiometer (MODIS) onboard the EOS Terra and Aqua satellites. In this paper we will present the functional description and capabilities of the S-NPP Land SIPS, including system development phases and production schedules, timeline for processing, and delivery of land science products based on coordination with the S-NPP Land science team members. The Land SIPS processing stream is expected to be operational by December 2016, generating land products either using the NASA science team delivered algorithms, or the "best-of" science algorithms currently in operation at NASA's Land Product Evaluation and Algorithm Testing Element (PEATE). In addition to generating the standard land science products through processing of the NASA's VIIRS Level 0 data record, the Land SIPS processing system is also used to produce a suite of near-real time products for NASA's application community. Land SIPS will also deliver the standard products, ancillary data sets, software and supporting documentation (ATBDs) to the assigned Distributed Active Archive Centers (DAACs) for archival and distribution. Quality assessment and validation will be an integral part of the Land SIPS processing system; the former being performed at Land Data Operational Product Evaluation (LDOPE) facility, while the latter under the auspices of the CEOS Working Group on Calibration & Validation (WGCV) Land Product Validation (LPV) Subgroup; adopting the best-practices and tools used to assess the quality of heritage EOS-MODIS products generated at the MODIS Adaptive Processing

  10. Reducing adolescent clients' anger in a residential substance abuse treatment facility.

    PubMed

    Adelman, Robert; McGee, Patricia; Power, Robert; Hanson, Cathy

    2005-06-01

    Sundown Ranch, a residential behavioral health care treatment facility for adolescents, tracked the progress and results of treatment by selecting performance measures from a psychosocial screening inventory. The temper scale was one of the two highest scales at admission and the highest scale at discharge. A clinical performance improvement (PI) project was conducted to assess improvements in clients' ability to manage anger after the incorporation of Rational Emotive Behavior Therapy (REBT) into treatment. Eighteen months of baseline data (July 1, 1999 - February 1, 2001) were collected, and 20 months of data (May 1, 2001 - December 31, 2002) were collected after the introduction of the PI activity. In all, data were collected for 541 consecutive admissions. A comparison of five successive quarterly reviews indicated average scores of 1.4 standard deviations (SDs) above the mean on the temper scale before the PI activity and .45 SD above the mean after. The performance threshold of reduction of the average temper scale score to < or =1 SD was met for 17 of 20 months. The fact that the PI activity reduced the temper scale elevations by almost one full SD is highly suggestive of the efficacy of REBT with the treatment population. After the project was completed, REBT was promoted as an additional therapeutic modality within the treatment program.

  11. What is The Role of Land Value in The Urban Corridor?

    NASA Astrophysics Data System (ADS)

    Rakhmatulloh, A. R.; Buchori, I.; Pradoto, W.; Riyanto, B.; Winarendri, J.

    2018-02-01

    The high movement causes traffic congestion and indicates high movement intensity along the corridor. The higher attraction of the land use will encourage the higher attraction of movement and economic values in the location. This attraction is also affected by the high mobility in the corridor supported by available transport infrastructure. Thus this causes land values become increase significantly. Land use along the corridor can be seen as commercial function because this activity is able to survive in the premium location. The purpose of this research is to identify the effect of land use change toward land values in the commercial corridor. This research used positivistic method with descriptive analysis. The result shows that the land values change in commercial use in the corridor has different pattern of land use change pattern according to physical condition and land use which causes highly economic attraction. The new commercial land is influenced by the distance to city centre or CBD (Central Business District). Land use and public facilities that have local and city scope services do not give the significant impact to land values change.

  12. Suicidal behaviours in male and female users of illicit drugs recruited in drug treatment facilities.

    PubMed

    Arribas-Ibar, Elisabet; Suelves, Josep Maria; Sanchez-Niubò, Albert; Domingo-Salvany, Antònia; T Brugal, M

    We assessed prevalence of suicidal ideation and plans among illicit drug users and their association with contextual factors, by gender. Cross-sectional study. In a sample of 511 illicit drug users recruited during spring 2012 in drug treatment and prevention facilities in Catalonia (Spain), the prevalence of suicidal ideation/plans in the last 12 months was assessed. Poisson regression was used to examine associations between suicidal ideation/plans and various factors (socio-demographic, psychological, illegal drug market activities and marginal income generation activities, which included any reported sex work, stealing, peddling, begging or borrowing on credit from a dealer). The average age was 37.9 years (standard deviation: 8.62); 76.3% were men. Suicidal ideation/plans were reported by 30.8% of men and 38.8% of women, with no significant differences by age or gender. Recent aggression (male prevalence ratio [PR]=2.2; female PR=1.4), psychological treatment (male PR=1.2; female PR=1.3) and illegal/marginal income generation activities (male PR=1.5; female PR=1.1) were associated with suicidal ideation/plans. Men who trafficked were more likely to have suicidal ideation/plans (PR=1.3), while prison history was positive for women (PR=1.8) and negative for men (PR=0.7). Prevalence of suicidal ideation/plans was high among illicit drug users recruited from healthcare facilities. Besides psychological variables, participation in illegal market activities and crime ought to be considered in drug users' suicidal prevention. Suicide risk needs to be evaluated in drug treatment facilities and psychological status and context contemplated. Copyright © 2017 SESPAS. Publicado por Elsevier España, S.L.U. All rights reserved.

  13. Land use changes and its driving forces in hilly ecological restoration area based on gis and rs of northern china

    PubMed Central

    Gao, Peng; Niu, Xiang; Wang, Bing; Zheng, Yunlong

    2015-01-01

    Land use change is one of the important aspects of the regional ecological restoration research. With remote sensing (RS) image in 2003, 2007 and 2012, using geographic information system (GIS) technologies, the land use pattern changes in Yimeng Mountain ecological restoration area in China and its driving force factors were studied. Results showed that: (1) Cultivated land constituted the largest area during 10 years, and followed by forest land and grass land; cultivated land and unused land were reduced by 28.43% and 44.32%, whereas forest land, water area and land for water facilities and others were increased. (2) During 2003–2007, forest land change showed the largest, followed by unused land and grass land; however, during 2008–2012, water area and land for water facilities change showed the largest, followed by grass land and unused land. (3) Land use degree was above the average level, it was in the developing period during 2003–2007 and in the degenerating period during 2008–2012. (4) Ecological Restoration Projects can greatly change the micro topography, increase vegetation coverage, and then induce significant changes in the land use distribution, which were the main driving force factors of the land use pattern change in the ecological restoration area. PMID:26047160

  14. STS-87 Columbia Landing at KSC

    NASA Technical Reports Server (NTRS)

    1997-01-01

    With Commander Kevin Kregel and Pilot Steven Lindsey at the controls, the orbiter Columbia touches its main gear down on Runway 33 at KSCs Shuttle Landing Facility at 7:20:04 a.m. EST Dec. 5 to complete the 15-day, 16-hour and 34-minute-long STS-87 mission of 6.5 million miles. Also onboard the orbiter are Mission Specialists Winston Scott; Kalpana Chawla, Ph.D.; and Takao Doi, Ph.D., of the National Space Development Agency of Japan; along with Payload Specialist Leonid Kadenyuk of the National Space Agency of Ukraine. During the 88th Space Shuttle mission, the crew performed experiments on the United States Microgravity Payload-4 and pollinated plants as part of the Collaborative Ukrainian Experiment. This was the 12th landing for Columbia at KSC and the 41st KSC landing in the history of the Space Shuttle program.

  15. STS-87 Columbia landing at KSC

    NASA Technical Reports Server (NTRS)

    1997-01-01

    With Commander Kevin Kregel and Pilot Steven Lindsey at the controls, the orbiter Columbia makes a smooth touchdown on Runway 33 at KSCs Shuttle Landing Facility at 7:20:04 a.m. EST Dec. 5, completing the 15-day, 16-hour and 34-minute-long STS-87 mission of 6.5 million miles. Also onboard the orbiter are Mission Specialists Winston Scott; Kalpana Chawla, Ph.D.; and Takao Doi, Ph.D., of the National Space Development Agency of Japan; along with Payload Specialist Leonid Kadenyuk of the National Space Agency of Ukraine. During the 88th Space Shuttle mission, the crew performed experiments on the United States Microgravity Payload-4 and pollinated plants as part of the Collaborative Ukrainian Experiment. This was the 12th landing for Columbia at KSC and the 41st KSC landing in the history of the Space Shuttle program.

  16. Land Application of Wastes: An Educational Program. Soil as a Treatment Medium - Module 3, Objectives, Script and Booklet.

    ERIC Educational Resources Information Center

    Clarkson, W. W.; And Others

    This module examines the basic properties of soil which have an influence on the success of land treatment of wastes. These relevant properties include soil texture, soil structure, permeability, infiltration, available water capacity, and cation exchange capacity. Biological, chemical and physical mechanisms work to remove and renovate wastes…

  17. HIV treatment and care services for adolescents: a situational analysis of 218 facilities in 23 sub-Saharan African countries.

    PubMed

    Mark, Daniella; Armstrong, Alice; Andrade, Catarina; Penazzato, Martina; Hatane, Luann; Taing, Lina; Runciman, Toby; Ferguson, Jane

    2017-05-16

    In 2013, an estimated 2.1 million adolescents (age 10-19 years) were living with HIV globally. The extent to which health facilities provide appropriate treatment and care was unknown. To support understanding of service availability in 2014, Paediatric-Adolescent Treatment Africa (PATA), a non-governmental organisation (NGO) supporting a network of health facilities across sub-Saharan Africa, undertook a facility-level situational analysis of adolescent HIV treatment and care services in 23 countries. Two hundred and eighteen facilities, responsible for an estimated 80,072 HIV-infected adolescents in care, were surveyed. Sixty per cent of the sample were from PATA's network, with the remaining gathered via local NGO partners and snowball sampling. Data were analysed using descriptive statistics and coding to describe central tendencies and identify themes. Respondents represented three subregions: West and Central Africa ( n  = 59; 27%), East Africa ( n  = 77, 35%) and southern Africa ( n  = 82, 38%). Half (50%) of the facilities were in urban areas, 17% peri-urban and 33% rural settings. Insufficient data disaggregation and outcomes monitoring were critical issues. A quarter of facilities did not have a working definition of adolescence. Facilities reported non-adherence as their key challenge in adolescent service provision, but had insufficient protocols for determining and managing poor adherence and loss to follow-up. Adherence counselling focused on implications of non-adherence rather than its drivers. Facilities recommended peer support as an effective adherence and retention intervention, yet not all offered these services. Almost two-thirds reported attending to adolescents with adults and/or children, and half had no transitioning protocols. Of those with transitioning protocols, 21% moved pregnant adolescents into adult services earlier than their peers. There was limited sexual and reproductive health integration, with 63% of facilities

  18. Huntington's Disease Outpatient Clinic for Functional Diagnosis and Treatment: Coming to Consensus: How Long Term Care Facility Procedures Complement Specialist Diagnosis and Treatment.

    PubMed

    Veenhuizen, Ruth; Nijsten, Hanneke; van Roosmalen, Paul; Lammertsen, Karen; Stor, Tom; de Jager, Lia; de Man, Jesseke; van der Doelen, Rina; Landa, Karin; Grond, Vera; Heffels, Joyce; Groenewoud, Rinske; Rovers, Luce; Bakker, Christian; Leiwakabessy, Saskia; van der Wedden, Dirk; van Blitterswijk, Jacqueline; van den Bosch, Dieuwke

    2018-01-01

    Huntington's disease (HD) patients and families deserve expert treatment and care throughout their lives, but uniformity in functional diagnosis and treatment was lacking. In the aim of reaching this uniformity on day-to-day treatment and care offered by multidisciplinary outreach teams from Dutch long term care facilities for ambulatory HD patients, a consensus trajectory was started to harmonise our care programme with international standards and within the country. The consensus statements, given as supplementary material, should lead to expert treatment and care for HD families throughout the Netherlands and this manuscript should contribute and revitalise a global discussion on standards of treatment and care.

  19. GIS analysis of the siting criteria for the Mixed and Low-Level Waste Treatment Facility and the Idaho Waste Processing Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoskinson, R.L.

    1994-01-01

    This report summarizes a study conducted using the Arc/Info{reg_sign} geographic information system (GIS) to analyze the criteria used for site selection for the Mixed and Low-Level Waste Treatment Facility (MLLWTF) and the Idaho Waste Processing Facility (IWPF). The purpose of the analyses was to determine, based on predefined criteria, the areas on the INEL that best satisfied the criteria. The coverages used in this study were produced by importing the AutoCAD files that produced the maps for a pre site selection draft report into the GIS. The files were then converted to Arc/Info{reg_sign} GIS format. The initial analysis was mademore » by considering all of the criteria as having equal importance in determining the areas of the INEL that would best satisfy the requirements. Another analysis emphasized four of the criteria as ``must`` criteria which had to be satisfied. Additional analyses considered other criteria that were considered for, but not included in the predefined criteria. This GIS analysis of the siting criteria for the IWPF and MLLWTF provides a logical, repeatable, and defensible approach to the determination of candidate locations for the facilities. The results of the analyses support the location of the Candidate Locations.« less

  20. STS-94 Columbia Landing at KSC (main gear touchdown)

    NASA Technical Reports Server (NTRS)

    1997-01-01

    With its drag chute deployed, the Space Shuttle Orbiter Columbia touches down on Runway 33 at KSCs Shuttle Landing Facility at 6:46:34 a.m. EDT with Mission Commander James D. Halsell Jr. and Pilot Susan L. Still at the controls to complete the STS-94 mission. Also on board are Mission Specialist Donald A. Thomas, Mission Specialist Michael L. Gernhardt , Payload Commander Janice Voss, and Payload Specialists Roger K. Crouch and Gregory T. Linteris. Mission elapsed time for STS-94 was 15 days,16 hours, 44 seconds. During the Microgravity Science Laboratory-1 (MSL-1) mission, the Spacelab module was used to test some of the hardware, facilities and procedures that are planned for use on the International Space Station while the flight crew conducted combustion, protein crystal growth and materials processing experiments. This mission was a reflight of the STS-83 mission that lifted off from KSC in April of this year. That space flight was cut short due to indications of a faulty fuel cell. This was Columbias 11th landing at KSC and the 38th landing at the space center in the history of the Shuttle program.

  1. Biological Information Document, Radioactive Liquid Waste Treatment Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Biggs, J.

    1995-12-31

    This document is intended to act as a baseline source material for risk assessments which can be used in Environmental Assessments and Environmental Impact Statements. The current Radioactive Liquid Waste Treatment Facility (RLWTF) does not meet current General Design Criteria for Non-reactor Nuclear Facilities and could be shut down affecting several DOE programs. This Biological Information Document summarizes various biological studies that have been conducted in the vicinity of new Proposed RLWTF site and an Alternative site. The Proposed site is located on Mesita del Buey, a mess top, and the Alternative site is located in Mortandad Canyon. The Proposedmore » Site is devoid of overstory species due to previous disturbance and is dominated by a mixture of grasses, forbs, and scattered low-growing shrubs. Vegetation immediately adjacent to the site is a pinyon-juniper woodland. The Mortandad canyon bottom overstory is dominated by ponderosa pine, willow, and rush. The south-facing slope was dominated by ponderosa pine, mountain mahogany, oak, and muhly. The north-facing slope is dominated by Douglas fir, ponderosa pine, and oak. Studies on wildlife species are limited in the vicinity of the proposed project and further studies will be necessary to accurately identify wildlife populations and to what extent they utilize the project area. Some information is provided on invertebrates, amphibians and reptiles, and small mammals. Additional species information from other nearby locations is discussed in detail. Habitat requirements exist in the project area for one federally threatened wildlife species, the peregrine falcon, and one federal candidate species, the spotted bat. However, based on surveys outside of the project area but in similar habitats, these species are not expected to occur in either the Proposed or Alternative RLWTF sites. Habitat Evaluation Procedures were used to evaluate ecological functioning in the project area.« less

  2. [Cancer treatment situation in Japan with regard to the type of medical facility using medical claim data of Health Insurance Societies].

    PubMed

    Tanaka, Hirokazu; Nakamura, Fumiaki; Higashi, Takahiro; Kobayashi, Yasuki

    2015-01-01

    Analyzing the cancer treatment situation in Japan is an important public health issue, especially because of increasing crude cancer morbidity in a rapidly aging society. This study aimed to examine where cancer patients received treatment, with special attention to designated regional cancer hospitals, and the treatment modality they received. Using health insurance claim data (1,064,875 subjects on December 2011) managed by the Japan Medical Data Center, we included patients that received treatments for stomach, colon, liver, lung, or breast cancer, the most common cancers in Japan, between 2005 and 2011. We divided the medical facilities where they were treated into five groups: prefectural designated regional cancer hospitals, local designated regional cancer hospitals, large/medium hospitals (≥100 beds), small hospitals (20-99 beds), and clinics (0-19 beds). We calculated the percentage of patients treated at each type of medical facility with different treatment modalities. The study included 2,901 patients. In total, 43.9% patients were treated at designated regional cancer hospitals (prefectural or local). This percentage was the highest for lung cancer (60.0%) and the lowest for colon cancer (31.3%). Surgeries for liver cancer (67.6%) and lung cancer (61.9%) were performed more at designated regional cancer hospitals (prefectural or local) than surgeries for stomach cancer (45.5%), colon cancer (40.1%), and breast cancer (49.8%). Some procedures were performed at small hospitals or clinics (surgery for stomach cancer [9.4%], surgery for breast cancer [9.3%], endoscopic procedures for stomach cancer [14.1%] and colon cancer [40.6%], and chemotherapy for breast cancer [11.4%]). Colon and breast cancer patients treated at prefectural designated regional cancer hospitals or clinics were younger than those treated at other types of facilities. The distribution of facilities at which cancer patients received treatment differed significantly according to cancer

  3. STS-65 Columbia, OV-102, with drag chute deployed lands at KSC SLF

    NASA Technical Reports Server (NTRS)

    1994-01-01

    The Space Shuttle Columbia, Orbiter Vehicle (OV) 102, its drag chute fully deployed, completes a record duration mission as it lands on Runway 33 at the Kennedy Space Center (KSC) Shuttle Landing Facility (SLF). A helicopter flying overhead observes as OV-102's nose landing gear (NLG) and main landing gear (MLG) roll along the runway. Landing occurred at 6:38 am (Eastern Daylight Time (EDT)). STS-65 mission duration was 14 days 17 hours and 56 minutes. Onboard were six NASA astronauts and a Japanese payload specialist who conducted experiments in support of the International Microgravity Laboratory 2 (IML-2) during the mission.

  4. High-Resolution Mesoscale Simulations of the 6-7 May 2000 Missouri Flash Flood: Impact of Model Initialization and Land Surface Treatment

    NASA Technical Reports Server (NTRS)

    Baker, R. David; Wang, Yansen; Tao, Wei-Kuo; Wetzel, Peter; Belcher, Larry R.

    2004-01-01

    High-resolution mesoscale model simulations of the 6-7 May 2000 Missouri flash flood event were performed to test the impact of model initialization and land surface treatment on timing, intensity, and location of extreme precipitation. In this flash flood event, a mesoscale convective system (MCS) produced over 340 mm of rain in roughly 9 hours in some locations. Two different types of model initialization were employed: 1) NCEP global reanalysis with 2.5-degree grid spacing and 12-hour temporal resolution, and 2) Eta reanalysis with 40- km grid spacing and $hour temporal resolution. In addition, two different land surface treatments were considered. A simple land scheme. (SLAB) keeps soil moisture fixed at initial values throughout the simulation, while a more sophisticated land model (PLACE) allows for r interactive feedback. Simulations with high-resolution Eta model initialization show considerable improvement in the intensity of precipitation due to the presence in the initialization of a residual mesoscale convective vortex (hlCV) from a previous MCS. Simulations with the PLACE land model show improved location of heavy precipitation. Since soil moisture can vary over time in the PLACE model, surface energy fluxes exhibit strong spatial gradients. These surface energy flux gradients help produce a strong low-level jet (LLJ) in the correct location. The LLJ then interacts with the cold outflow boundary of the MCS to produce new convective cells. The simulation with both high-resolution model initialization and time-varying soil moisture test reproduces the intensity and location of observed rainfall.

  5. A needs analysis method for land-use planning of illegal dumping sites: a case study in Aomori-Iwate, Japan.

    PubMed

    Ishii, Kazuei; Furuichi, Toru; Nagao, Yukari

    2013-02-01

    Land use at contaminated sites, following remediation, is often needed for regional redevelopment. However, there exist few methods of developing economically and socially feasible land-use plans based on regional needs because of the wide variety of land-use requirements. This study proposes a new needs analysis method for the conceptual land-use planning of contaminated sites and illustrates this method with a case study of an illegal dumping site for hazardous waste. In this method, planning factors consisting of the land-use attributes and related facilities are extracted from the potential needs of the residents through a preliminary questionnaire. Using the extracted attributes of land use and the related facilities, land-use cases are designed for selection-based conjoint analysis. A second questionnaire for respondents to the first one who indicated an interest in participating in the second questionnaire is conducted for the conjoint analysis to determine the utility function and marginal cost of each attribute in order to prioritize the planning factors to develop a quantitative and economically and socially feasible land-use plan. Based on the results, site-specific land-use alternatives are developed and evaluated by the utility function obtained from the conjoint analysis. In this case study of an illegal dumping site for hazardous waste, the uses preferred as part of a conceptual land-use plan following remediation of the site were (1) agricultural land and a biogas plant designed to recover energy from biomass or (2) a park with a welfare facility and an athletic field. Our needs analysis method with conjoint analysis is applicable to the development of conceptual land-use planning for similar sites following remediation, particularly when added value is considered. Copyright © 2012 Elsevier Ltd. All rights reserved.

  6. Extended Statistical Short-Range Guidance for Peak Wind Speed Analyses at the Shuttle Landing Facility: Phase II Results

    NASA Technical Reports Server (NTRS)

    Lambert, Winifred C.

    2003-01-01

    This report describes the results from Phase II of the AMU's Short-Range Statistical Forecasting task for peak winds at the Shuttle Landing Facility (SLF). The peak wind speeds are an important forecast element for the Space Shuttle and Expendable Launch Vehicle programs. The 45th Weather Squadron and the Spaceflight Meteorology Group indicate that peak winds are challenging to forecast. The Applied Meteorology Unit was tasked to develop tools that aid in short-range forecasts of peak winds at tower sites of operational interest. A seven year record of wind tower data was used in the analysis. Hourly and directional climatologies by tower and month were developed to determine the seasonal behavior of the average and peak winds. Probability density functions (PDF) of peak wind speed were calculated to determine the distribution of peak speed with average speed. These provide forecasters with a means of determining the probability of meeting or exceeding a certain peak wind given an observed or forecast average speed. A PC-based Graphical User Interface (GUI) tool was created to display the data quickly.

  7. Final closure plan for the high-explosives open burn treatment facility at Lawrence Livermore National Laboratory Experimental Test Site 300

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mathews, S.

    This document addresses the interim status closure of the HE Open Bum Treatment Facility, as detailed by Title 22, Division 4.5, Chapter 15, Article 7 of the Califonia Code of Regulations (CCR) and by Title 40, Code of Federal Regulations (CFR) Part 265, Subpart G, ``Closure and Post Closure.`` The Closure Plan (Chapter 1) and the Post- Closure Plan (Chapter 2) address the concept of long-term hazard elimination. The Closure Plan provides for capping and grading the HE Open Bum Treatment Facility and revegetating the immediate area in accordance with applicable requirements. The Closure Plan also reflects careful consideration ofmore » site location and topography, geologic and hydrologic factors, climate, cover characteristics, type and amount of wastes, and the potential for contaminant migration. The Post-Closure Plan is designed to allow LLNL to monitor the movement, if any, of pollutants from the treatment area. In addition, quarterly inspections will ensure that all surfaces of the closed facility, including the cover and diversion ditches, remain in good repair, thus precluding the potential for contaminant migration.« less

  8. Industrial hygiene report, preliminary survey of wood preservative treatment facility at Koppers Company, Inc. , Forest Products Group, Florence, South Carolina

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Todd, A.S.; Timbie, C.Y.

    1979-11-16

    A walk through survey was conducted at Koppers Company, Incorporated, Florence, South Carolina in July, 1984. The facility treated poles, posts, and railroad ties with creosote, pentachlorophenol, or chromated copper arsenate. Pentachlorophenol monitoring was performed and showed pentachlorophenol exposures of 0.04 to 0.12 mg/cm/sup 3/. Sampling was attempted for creosote, but the data were invalid due to faulty analytical techniques. The facility employed 141 people, of whom 125 were production workers and 16 were administrative staff. All employees were required to wear hard hats and safety shoes. Treatment operators and helpers were supplied with eye protection, gloves, boots, disposable coveralls,more » and slickers when needed. Respirators were provided when entering treatment cylinders. Preemployment medical examinations were conducted on all new employees. Periodical physicals were not offered. No physician or licensed nurse was located on site. Two employees trained in first aid were responsible for providing emergency treatment. About half of the employees used work uniforms while the remainder brought work clothing from home. Showers and change room facilities were provided.« less

  9. Final Environmental Assessment: For Okaloosa County Wastewater Treatment Facility Eglin Air Force Base, Florida

    DTIC Science & Technology

    2004-04-01

    growth , area development, and additional wastewater from Okaloosa Island that is being pumped to the wastewater treatment facility, it is approaching its...a wavelength of 254 nanometers (nm) kill viruses, bacteria , and protozoan, including Giardia and Cryptosporidium. Currently, the vast majority of...from the Proposed Action. Given the highly disturbed condition of the site and surrounding area, expansion at this site would not adversely

  10. Landing of STS-60 Space Shuttle Discovery at Kennedy Space Center

    NASA Image and Video Library

    1994-02-11

    STS060-S-035 (11 Feb 1994) --- The drag chute for Space Shuttle Discovery is deployed on the Shuttle Landing Facility, marking an end to the eight-day STS-60 mission. Landing occurred at 2:19:22 p.m. (EST). Onboard were astronauts Charles F. Bolden Jr., Kenneth S. Reightler Jr., Franklin R. Chang-Diaz, N. Jan Davis and Ronald M. Sega along with Russian cosmonaut Sergei K. Krikalev.

  11. Report: American Recovery and Reinvestment Act Site Visit of the Wastewater Treatment Facility Improvements Project, Perkins, Oklahoma

    EPA Pesticide Factsheets

    Report #11-R-0214, May 2, 2011. We conducted an unannounced visit of the construction site of the Perkins Public Works Authority’s wastewater treatment facility improvements project in Perkins, Oklahoma, on April 19–22, 2010.

  12. 1995 Report on Hanford site land disposal restrictions for mixed waste

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Black, D.G.

    This report was submitted to meet the requirements of Hanford Federal Facility Agreement and Consent Order Milestone M-26-01E. This milestone requires the preparation of an annual report that covers characterization, treatment, storage, minimization, and other aspects of land disposal restricted mixed waste at the Hanford Site. The U.S. Department of Energy, its predecessors, and contractors at the Hanford Site were involved in the production and purification of nuclear defense materials from the early 1940s to the late 1980s. These production activities have generated large quantities of liquid and solid radioactive mixed waste. This waste is subject to regulation under authoritymore » of both the Resource Conservation and Recovery Act of 1976 and Atomic Energy Act of 1954. This report covers mixed waste only. The Washington State Department of Ecology, U.S. Environmental Protection Agency, and U.S. Department of Energy have entered into an agreement, the Hanford Federal Facility Agreement and Consent Order (commonly referred to as the Tri-Party Agreement) to bring the Hanford Site operations into compliance with dangerous waste regulations. The Tri-Party Agreement required development of the original land disposal restrictions (LDRs) plan and its annual updates to comply with LDR requirements for radioactive mixed waste. This report is the fifth update of the plan first issued in 1990. Tri-Party Agreement negotiations completed in 1993 and approved in January 1994 changed and added many new milestones. Most of the changes were related to the Tank Waste Remediation System and these changes are incorporated into this report.« less

  13. 18 CFR 2.60 - Facilities and activities during an emergency-accounting treatment of defense-related expenditures.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 18 Conservation of Power and Water Resources 1 2012-04-01 2012-04-01 false Facilities and activities during an emergency-accounting treatment of defense-related expenditures. 2.60 Section 2.60 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY GENERAL...

  14. 18 CFR 2.60 - Facilities and activities during an emergency-accounting treatment of defense-related expenditures.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Facilities and activities during an emergency-accounting treatment of defense-related expenditures. 2.60 Section 2.60 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY GENERAL...

  15. 18 CFR 2.60 - Facilities and activities during an emergency-accounting treatment of defense-related expenditures.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 18 Conservation of Power and Water Resources 1 2014-04-01 2014-04-01 false Facilities and activities during an emergency-accounting treatment of defense-related expenditures. 2.60 Section 2.60 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY GENERAL...

  16. 18 CFR 2.60 - Facilities and activities during an emergency-accounting treatment of defense-related expenditures.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 18 Conservation of Power and Water Resources 1 2013-04-01 2013-04-01 false Facilities and activities during an emergency-accounting treatment of defense-related expenditures. 2.60 Section 2.60 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY GENERAL...

  17. The experience of relocation for specialist treatment for Indigenous women diagnosed with vulvar cancer in East Arnhem Land.

    PubMed

    McGrath, Pam; Rawson, Nicole

    2013-01-01

    Vulvar cancer is a serious condition that requires a range of specialist treatments including surgery, chemotherapy, and radiation. In Australia, such treatments are only available in major metropolitan hospitals. Thus, women diagnosed with this condition in rural and remote areas must relocate to the metropolitan specialist centers for treatment. The focus of this article is on the experience of relocation for specialist care for Indigenous women diagnosed with vulvar cancer from East Arnhem Land, Northern Territory, Australia. The findings presented in this article explore a range of issues that affect the experience of relocation such as community concerns, cultural distress, loneliness, fear, worry, and physical concerns associated with the condition.

  18. STS-106 crew poses for photos after landing

    NASA Technical Reports Server (NTRS)

    2000-01-01

    Standing in front of the orbiter Atlantis after a successful landing at the Shuttle Landing Facility, the STS-106 crew greets the media and onlookers. Standing, left to right, are Mission Specialists Yuri I. Malenchenko, Boris V. Morukov, Daniel C. Burbank and Richard A. Mastracchio; Pilot Scott D. Altman; Mission Specialist Edward T. Lu; and Commander Terrence W. Wilcutt at the microphone. Main gear touchdown occurred on-time at 3:56:48 a.m. EDT. Atlantis and crew traveled 4.9 million miles on the 11-day, 19-hour, 11-minute STS-106 mission. During the mission to the International Space Station, the crew transferred nearly 5,000 pounds of equipment and supplies for use by the first resident crew expected to arrive in November. STs-106 was the 99th flight in the Shuttle program and the 22nd for Atlantis. STS-106 also marked the 15th nighttime landing in Shuttle history and the 23rd consecutive landing at KSC.

  19. STS-90 Columbia landing at KSC's runway 33

    NASA Technical Reports Server (NTRS)

    1998-01-01

    The orbiter Columbia touches down on Runway 33 of KSC's Shuttle Landing Facility to complete the nearly 16-day STS-90 mission. Main gear touchdown was at 12:08:59 p.m. EDT on May 3, 1998, landing on orbit 256 of the mission. The wheels stopped at 12:09:58 EDT, completing a total mission time of 15 days, 21 hours, 50 minutes and 58 seconds. The 90th Shuttle mission was Columbia's 13th landing at the space center and the 43rd KSC landing in the history of the Space Shuttle program. During the mission, the crew conducted research to contribute to a better understanding of the human nervous system. The crew of the STS-90 Neurolab mission include Commander Richard Searfoss; Pilot Scott Altman; Mission Specialists Richard Linnehan, D.V.M., Dafydd (Dave) Williams, M.D., with the Canadian Space Agency, and Kathryn (Kay) Hire; and Payload Specialists Jay Buckey, M.D., and James Pawelczyk, Ph.D.

  20. Methane correction factors for estimating emissions from aerobic wastewater treatment facilities based on field data in Mexico and on literature review.

    PubMed

    Noyola, A; Paredes, M G; Güereca, L P; Molina, L T; Zavala, M

    2018-10-15

    Wastewater treatment (WWT) may be an important source of methane (CH 4 ), a greenhouse gas with significant global warming potential. Sources of CH 4 emissions from WWT facilities can be found in the water and in the sludge process lines. Among the methodologies for estimating CH 4 emissions inventories from WWT, the more adopted are the guidelines of the Intergovernmental Panel on Climate Change (IPCC), which recommends default emission factors (Tier 1) depending on WWT systems. Recent published results show that well managed treatment facilities may emit CH 4 , due to dissolved CH 4 in the influent wastewater; in addition, biological nutrient removal also will produce this gas in the anaerobic (or anoxic) steps. However, none of these elements is considered in the current IPCC guidelines. The aim of this work is to propose modified (and new) methane correction factors (MCF) regarding the current Tier 1 IPCC guidelines for CH 4 emissions from aerobic treatment systems, with and without anaerobic sludge digesters, focusing on intertropical countries. The modifications are supported on in situ assessment of fugitive CH 4 emissions in two facilities in Mexico and on relevant literature data. In the case of well-managed centralized aerobic treatment plant, a MCF of 0.06 (instead of the current 0.0) is proposed, considering that the assumption of a CH 4 -neutral treatment facility, as established in the IPCC methodology, is not supported. Similarly, a MCF of 0.08 is proposed for biological nutrient removal processes, being a new entry in the guidelines. Finally, a one-step straightforward calculation is proposed for centralized aerobic treatment plants with anaerobic digesters that avoids confusion when selecting the appropriate default MCF based on the Tier 1 IPCC guidelines. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.