Sample records for facility acrf fixed

  1. Atmospheric Radiation Measurement program climate research facility operations quarterly report October 1 - December 31, 2006.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sisterson, D. L.

    2007-03-14

    Individual raw data streams from instrumentation at the Atmospheric Radiation Measurement (ARM) Program Climate Research Facility (ACRF) fixed and mobile sites are collected and sent to the Data Management Facility (DMF) at Pacific Northwest National Laboratory (PNNL) for processing in near real time. Raw and processed data are then sent daily to the ACRF Archive, where they are made available to users. For each instrument, we calculate the ratio of the actual number of data records received daily at the Archive to the expected number of data records. The results are tabulated by (1) individual data stream, site, and monthmore » for the current year and (2) site and fiscal year dating back to 1998. Table 1 shows the accumulated maximum operation time (planned uptime), the actual hours of operation, and the variance (unplanned downtime) for the period October 1 through December 31, 2006, for the fixed and mobile sites. Although the AMF is currently up and running in Niamey, Niger, Africa, the AMF statistics are reported separately and not included in the aggregate average with the fixed sites. The first quarter comprises a total of 2,208 hours. For all fixed sites, the actual data availability (and therefore actual hours of operation) exceeded the individual (and well as aggregate average of the fixed sites) operational goal for the first quarter of fiscal year (FY) 2007. The Site Access Request System is a web-based database used to track visitors to the fixed sites, all of which have facilities that can be visited. The NSA locale has the Barrow and Atqasuk sites. The SGP site has a Central Facility, 23 extended facilities, 4 boundary facilities, and 3 intermediate facilities. The TWP locale has the Manus, Nauru, and Darwin sites. NIM represents the AMF statistics for the current deployment in Niamey, Niger, Africa. PYE represents the AMF statistics for the Point Reyes, California, past deployment in 2005. In addition, users who do not want to wait for data to be provided through the ACRF Archive can request an account on the local site data system. The eight research computers are located at the Barrow and Atqasuk sites; the SGP Central Facility; the TWP Manus, Nauru, and Darwin sites; the DMF at PNNL; and the AMF in Niger. This report provides the cumulative numbers of visitors and user accounts by site for the period January 1, 2006 - December 31, 2006. The U.S. Department of Energy requires national user facilities to report facility use by total visitor days-broken down by institution type, gender, race, citizenship, visitor role, visit purpose, and facility-for actual visitors and for active user research computer accounts. During this reporting period, the ACRF Archive did not collect data on user characteristics in this way. Work is under way to collect and report these data. Table 2 shows the summary of cumulative users for the period January 1, 2006 - December 31, 2006. For the first quarter of FY 2007, the overall number of users is up from the last reporting period. The historical data show that there is an apparent relationship between the total number of users and the 'size' of field campaigns, called Intensive Operation Periods (IOPs): larger IOPs draw more of the site facility resources, which are reflected by the number of site visits and site visit days, research accounts, and device accounts. These types of users typically collect and analyze data in near-real time for a site-specific IOP that is in progress. However, the Archive accounts represent persistent (year-to-year) ACRF data users that often mine from the entire collection of ACRF data, which mostly includes routine data from the fixed and mobile sites, as well as cumulative IOP data sets. Archive data users continue to show a steady growth, which is independent of the size of IOPs. For this quarter, the number of Archive data user accounts was 961, the highest since record-keeping began. For reporting purposes, the three ACRF sites and the AMF operate 24 hours per day, 7 days per week, and 52 weeks per year. Although the AMF is not officially collecting data this quarter, personnel are regularly involved with teardown, packing, hipping, unpacking, setup, and maintenance activities, so they are included in the safety statistics. Time is reported in days instead of hours. If any lost work time is incurred by any employee, it is counted as a workday loss. Table 3 reports the consecutive days since the last recordable or reportable injury or incident causing damage to property, equipment, or vehicle for the period October 1 - December 31, 2006. There were no recordable or lost workdays or incidents for the first quarter of FY 2007.« less

  2. Atmospheric Radiation Measurement program climate research facility operations quarterly report January 1 - March 31, 2008.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sisterson, D. L.

    2008-05-22

    Individual raw data streams from instrumentation at the Atmospheric Radiation Measurement (ARM) Program Climate Research Facility (ACRF) fixed and mobile sites are collected and sent to the Data Management Facility (DMF) at Pacific Northwest National Laboratory (PNNL) for processing in near real time. Raw and processed data are then sent daily to the ACRF Archive, where they are made available to users. For each instrument, we calculate the ratio of the actual number of data records received daily at the Archive to the expected number of data records. The results are tabulated by (1) individual data stream, site, and monthmore » for the current year and (2) site and fiscal year (FY) dating back to 1998. Table 1 shows the accumulated maximum operation time (planned uptime), actual hours of operation, and variance (unplanned downtime) for the period January 1 - March 31, 2008, for the fixed sites. The AMF is being deployed to China and is not in operation this quarter. The second quarter comprises a total of 2,184 hours. The average as well as the individual site values exceeded our goal this quarter. The Site Access Request System is a web-based database used to track visitors to the fixed and mobile sites, all of which have facilities that can be visited. The NSA locale has the Barrow and Atqasuk sites. The SGP site has a central facility, 23 extended facilities, 4 boundary facilities, and 3 intermediate facilities. The TWP locale has the Manus, Nauru, and Darwin sites. FKB represents the AMF statistics for the Haselbach, Germany, past deployment in 2007. NIM represents the AMF statistics for the Niamey, Niger, Africa, past deployment in 2006. PYE represents just the AMF Archive statistics for the Point Reyes, California, past deployment in 2005. In addition, users who do not want to wait for data to be provided through the ACRF Archive can request a research account on the local site data system. The seven computers for the research accounts are located at the Barrow and Atqasuk sites; the SGP central facility; the TWP Manus, Nauru, and Darwin sites; and the DMF at PNNL. In addition, the ACRF serves as a data repository for a long-term Arctic atmospheric observatory in Eureka, Canada (80 degrees 05 minutes N, 86 degrees 43 minutes W) as part of the multiagency Study of Environmental Arctic Change (SEARCH) Program. NOAA began providing instruments for the site in 2005, and currently cloud radar data are available. The intent of the site is to monitor the important components of the Arctic atmosphere, including clouds, aerosols, atmospheric radiation, and local-scale atmospheric dynamics. Because of the similarity of ACRF NSA data streams and the important synergy that can be formed between a network of Arctic atmospheric observations, much of the SEARCH observatory data are archived in the ARM archive. Instruments will be added to the site over time. For more information, please visit http://www.db.arm.gov/data. The designation for the archived Eureka data is YEU and is now included in the ACRF user metrics. This quarterly report provides the cumulative numbers of visitors and user accounts by site for the period April 1, 2007 - March 31, 2008. Table 2 shows the summary of cumulative users for the period April 1, 2007 - March 31, 2007. For the second quarter of FY 2008, the overall number of users was nearly as high as the last reporting period, in which a new record high for number of users was established. This quarter, a new record high was established for the number of user days, particularly due to the large number of field campaign activities in conjunction with the AMF deployment in Germany, as well as major field campaigns at the NSA and SGP sites. This quarter, 37% of the Archive users are ARM science-funded principal investigators and 23% of all other facility users are either ARM science-funded principal investigators or ACRF infrastructure personnel. For reporting purposes, the three ACRF sites and the AMF operate 24 hours per day, 7 days per week, and 52 weeks per year. Time is reported in days instead of hours. If any lost work time is incurred by any employee, it is counted as a workday loss. Table 3 reports the consecutive days since the last recordable or reportable injury or incident causing damage to property, equipment, or vehicle for the period January 1 - March 31, 2008. There were no incidents this reporting period.« less

  3. Atmospheric Radiation Measurement program climate research facility operations quarterly report October 1 - December 31, 2007.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sisterson, D. L.

    2008-01-24

    Individual raw data streams from instrumentation at the Atmospheric Radiation Measurement (ARM) Program Climate Research Facility (ACRF) fixed and mobile sites are collected and sent to the Data Management Facility (DMF) at Pacific Northwest National Laboratory (PNNL) for processing in near real time. Raw and processed data are then sent daily to the ACRF Archive, where they are made available to users. For each instrument, we calculate the ratio of the actual number of data records received daily at the Archive to the expected number of data records. The results are tabulated by (1) individual data stream, site, and monthmore » for the current year and (2) site and fiscal year (FY) dating back to 1998. Table 1 shows the accumulated maximum operation time (planned uptime), actual hours of operation, and variance (unplanned downtime) for the period October 1 - December 31, 2007, for the fixed sites and the mobile site. The AMF has been deployed to Germany and this was the final operational quarter. The first quarter comprises a total of 2,208 hours. Although the average exceeded our goal this quarter, a series of severe weather events (i.e., widespread ice storms) disrupted utility services, which affected the SGP performance measures. Some instruments were covered in ice and power and data communication lines were down for more than 10 days in some areas of Oklahoma and Kansas, which resulted in lost data at the SGP site. The Site Access Request System is a web-based database used to track visitors to the fixed sites, all of which have facilities that can be visited. The NSA locale has the Barrow and Atqasuk sites. The SGP site has a central facility, 23 extended facilities, 4 boundary facilities, and 3 intermediate facilities. The TWP locale has the Manus, Nauru, and Darwin sites. The AMF completed its mission at the end of this quarter in Haselback, Germany (FKB designation). NIM represents the AMF statistics for the Niamey, Niger, Africa, past deployment in 2006. PYE represents just the AMF Archive statistics for the Point Reyes, California, past deployment in 2005. In addition, users who do not want to wait for data to be provided through the ACRF Archive can request an account on the local site data system. The eight research computers are located at the Barrow and Atqasuk sites; the SGP central facility; the TWP Manus, Nauru, and Darwin sites; the DMF at PNNL; and the AMF, currently in Germany. In addition, the ACRF serves as a data repository for a long-term Arctic atmospheric observatory in Eureka, Canada (80 degrees 05 minutes N, 86 degrees 43 minutes W) as part of the multiagency Study of Environmental Arctic Change (SEARCH) Program. NOAA began providing instruments for the site in 2005, and currently cloud radar data are available. The intent of the site is to monitor the important components of the Arctic atmosphere, including clouds, aerosols, atmospheric radiation, and local-scale atmospheric dynamics. Due to the similarity of ACRF NSA data streams, and the important synergy that can be formed between a network of Arctic atmospheric observations, much of the SEARCH observatory data are archived in the ARM archive. Instruments will be added to the site over time. For more information, please visit http://www.db.arm.gov/data. The designation for the archived Eureka data is YEU and is now included in the ACRF user metrics. This quarterly report provides the cumulative numbers of visitors and user accounts by site for the period January 1, 2007 - December 31, 2007. Table 2 shows the summary of cumulative users for the period January 1, 2007 - December 31, 2007. For the first quarter of FY 2008, the overall number of users was up significantly from the last reporting period. For the fourth consecutive reporting period, a record high number of Archive users was recorded. In addition, the number of visitors and visitor days set a new record this reporting period particularly due to the large number of field campaign activities in conjunction with the AMF deployment in Germany. It is interesting to note this quarter that 22% (a slight decrease from last quarter) of the Archive users are ARM Science funded principal investigators and 35% (the same as last quarter) of all other facility users are either ARM Science-funded principal investigators or ACRF infrastructure personnel. For reporting purposes, the three ACRF sites and the AMF operate 24 hours per day, 7 days per week, and 52 weeks per year. Time is reported in days instead of hours. If any lost work time is incurred by any employee, it is counted as a workday loss. Table 3 reports the consecutive days since the last recordable or reportable injury or incident causing damage to property, equipment, or vehicle for the period October 1 - December 31, 2007. There were no incidents this reporting period.« less

  4. Atmospheric Radiation Measurement program climate research facility operations quarterly report July 1 - September 30, 2008.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sisterson, D. L.

    2008-10-08

    Individual raw data streams from instrumentation at the Atmospheric Radiation Measurement (ARM) Program Climate Research Facility (ACRF) fixed and mobile sites are collected and sent to the Data Management Facility (DMF) at Pacific Northwest National Laboratory (PNNL) for processing in near real-time. Raw and processed data are then sent daily to the ACRF Archive, where they are made available to users. For each instrument, we calculate the ratio of the actual number of data records received daily at the Archive to the expected number of data records. The results are tabulated by (1) individual data stream, site, and month formore » the current year and (2) site and fiscal year (FY) dating back to 1998. Table 1 shows the accumulated maximum operation time (planned uptime), actual hours of operation, and variance (unplanned downtime) for the period July 1 - September 30, 2008, for the fixed sites. The AMF has been deployed to China, but the data have not yet been released. The fourth quarter comprises a total of 2,208 hours. The average exceeded our goal this quarter. The Site Access Request System is a web-based database used to track visitors to the fixed and mobile sites, all of which have facilities that can be visited. The NSA locale has the Barrow and Atqasuk sites. The SGP site has a central facility, 23 extended facilities, 4 boundary facilities, and 3 intermediate facilities. The TWP locale has the Manus, Nauru, and Darwin sites. HFE represents the AMF statistics for the Shouxian, China, deployment in 2008. FKB represents the AMF statistics for the Haselbach, Germany, past deployment in 2007. NIM represents the AMF statistics for the Niamey, Niger, Africa, past deployment in 2006. PYE represents just the AMF Archive statistics for the Point Reyes, California, past deployment in 2005. In addition, users who do not want to wait for data to be provided through the ACRF Archive can request a research account on the local site data system. The seven computers for the research accounts are located at the Barrow and Atqasuk sites; the SGP central facility; the TWP Manus, Nauru, and Darwin sites; and the DMF at PNNL. In addition, the ACRF serves as a data repository for a long-term Arctic atmospheric observatory in Eureka, Canada (80 degrees 05 minutes N, 86 degrees 43 minutes W) as part of the multiagency Study of Environmental Arctic Change (SEARCH) Program. NOAA began providing instruments for the site in 2005, and currently cloud radar data are available. The intent of the site is to monitor the important components of the Arctic atmosphere, including clouds, aerosols, atmospheric radiation, and local-scale atmospheric dynamics. Because of the similarity of ACRF NSA data streams and the important synergy that can be formed between a network of Arctic atmospheric observations, much of the SEARCH observatory data are archived in the ARM archive. Instruments will be added to the site over time. For more information, please visit http://www.db.arm.gov/data. The designation for the archived Eureka data is YEU and is now included in the ACRF user metrics. This quarterly report provides the cumulative numbers of visitors and user accounts by site for the period October 1, 2007 - September 30, 2008. Table 2 shows the summary of cumulative users for the period October 1, 2007 - September 30, 2008. For the fourth quarter of FY 2008, the overall number of users is down substantially (about 30%) from last quarter. Most of this decrease resulted from a reduction in the ACRF Infrastructure users (e.g., site visits, research accounts, on-site device accounts, etc.) associated with the AMF China deployment. While users had easy access to the previous AMF deployment in Germany that resulted in all-time high user statistics, physical and remote access to on-site accounts are extremely limited for the AMF deployment in China. Furthermore, AMF data have not yet been released from China to the Data Management Facility for processing, which affects Archive user statistics. However, Archive users are only down about 10% from last quarter. Another reason for the apparent reduction in Archive users is that data from the Indirect and Semi-Direct Aerosol Campaign (ISDAC), a major field campaign conducted on the North Slope of Alaska, are not yet available to users. For reporting purposes, the three ACRF sites and the AMF operate 24 hours per day, 7 days per week, and 52 weeks per year. Time is reported in days instead of hours. If any lost work time is incurred by any employee, it is counted as a workday loss. Table 3 reports the consecutive days since the last recordable or reportable injury or incident causing damage to property, equipment, or vehicle for the period July 1 - September 30, 2008. There were no incidents this reporting period.« less

  5. Atmospheric Radiation Measurement Program Climate Research Facility Operations Quarterly Report. October 1 - December 31, 2009.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    D. L. Sisterson

    2010-01-12

    Individual raw data streams from instrumentation at the Atmospheric Radiation Measurement (ARM) Program Climate Research Facility (ACRF) fixed and mobile sites are collected and sent to the Data Management Facility (DMF) at Pacific Northwest National Laboratory (PNNL) for processing in near real-time. Raw and processed data are then sent approximately daily to the ACRF Archive, where they are made available to users. For each instrument, we calculate the ratio of the actual number of data records received daily at the Archive to the expected number of data records. The results are tabulated by (1) individual data stream, site, and monthmore » for the current year and (2) site and fiscal year (FY) dating back to 1998. The U.S. Department of Energy (DOE) requires national user facilities to report time-based operating data. The requirements concern the actual hours of operation (ACTUAL); the estimated maximum operation or uptime goal (OPSMAX), which accounts for planned downtime; and the VARIANCE [1 - (ACTUAL/OPSMAX)], which accounts for unplanned downtime. The OPSMAX time for the first quarter of FY 2010 for the North Slope Alaska (NSA) locale is 1,987.20 hours (0.90 x 2,208); for the Southern Great Plains (SGP) site is 2,097.60 hours (0.95 x 2,208); and for the Tropical Western Pacific (TWP) locale is 1,876.8 hours (0.85 x 2,208). The ARM Mobile Facility (AMF) deployment in Graciosa Island, the Azores, Portugal, continues; its OPSMAX time this quarter is 2,097.60 hours (0.95 x 2,208). The differences in OPSMAX performance reflect the complexity of local logistics and the frequency of extreme weather events. It is impractical to measure OPSMAX for each instrument or data stream. Data availability reported here refers to the average of the individual, continuous data streams that have been received by the Archive. Data not at the Archive are the result of downtime (scheduled or unplanned) of the individual instruments. Therefore, data availability is directly related to individual instrument uptime. Thus, the average percentage of data in the Archive represents the average percentage of the time (24 hours per day, 92 days for this quarter) the instruments were operating this quarter. The Site Access Request System is a web-based database used to track visitors to the fixed and mobile sites, all of which have facilities that can be visited. The NSA locale has the Barrow and Atqasuk sites. The SGP locale has historically had a central facility, 23 extended facilities, 4 boundary facilities, and 3 intermediate facilities. Beginning this quarter, the SGP began a transition to a smaller footprint (150 km x 150 km) by rearranging the original and new instrumentation made available through the American Recovery and Reinvestment Act (ARRA). The central facility and 4 extended facilities will remain, but there will be up to 16 surface new characterization facilities, 4 radar facilities, and 3 profiler facilities sited in the smaller domain. This new configuration will provide observations at scales more appropriate to current and future climate models. The TWP locale has the Manus, Nauru, and Darwin sites. These sites will also have expanded measurement capabilities with the addition of new instrumentation made available through ARRA funds. It is anticipated that the new instrumentation at all the fixed sites will be in place within the next 12 months. The AMF continues its 20-month deployment in Graciosa Island, Azores, Portugal, that started May 1, 2009. The AMF will also have additional observational capabilities within the next 12 months. Users can participate in field experiments at the sites and mobile facility, or they can participate remotely. Therefore, a variety of mechanisms are provided to users to access site information. Users who have immediate (real-time) needs for data access can request a research account on the local site data systems. This access is particularly useful to users for quick decisions in executing time-dependent activities associated with field campaigns at the fixed sites and mobile facility locations. The eight computers for the research accounts are located at the Barrow and Atqasuk sites; the SGP central facility; the TWP Manus, Nauru, and Darwin sites; the AMF; and the DMF at PNNL. However, users are warned that the data provided at the time of collection have not been fully screened for quality and therefore are not considered to be official ACRF data. Hence, these accounts are considered to be part of the facility activities associated with field campaign activities, and users are tracked. In addition, users who visit sites can connect their computer or instrument to an ACRF site data system network, which requires an on-site device account. Remote (off-site) users can also have remote access to any ACRF instrument or computer system at any ACRF site, which requires an off-site device account. These accounts are also managed and tracked.« less

  6. ARM Climate Research Facility: Outreach Tools and Strategies

    NASA Astrophysics Data System (ADS)

    Roeder, L.; Jundt, R.

    2009-12-01

    Sponsored by the Department of Energy, the ARM Climate Research Facility is a global scientific user facility for the study of climate change. To publicize progress and achievements and to reach new users, the ACRF uses a variety of Web 2.0 tools and strategies that build off of the program’s comprehensive and well established News Center (www.arm.gov/news). These strategies include: an RSS subscription service for specific news categories; an email “newsletter” distribution to the user community that compiles the latest News Center updates into a short summary with links; and a Facebook page that pulls information from the News Center and links to relevant information in other online venues, including those of our collaborators. The ACRF also interacts with users through field campaign blogs, like Discovery Channel’s EarthLive, to share research experiences from the field. Increasingly, field campaign Wikis are established to help ACRF researchers collaborate during the planning and implementation phases of their field studies and include easy to use logs and image libraries to help record the campaigns. This vital reference information is used in developing outreach material that is shared in highlights, news, and Facebook. Other Web 2.0 tools that ACRF uses include Google Maps to help users visualize facility locations and aircraft flight patterns. Easy-to-use comment boxes are also available on many of the data-related web pages on www.arm.gov to encourage feedback. To provide additional opportunities for increased interaction with the public and user community, future Web 2.0 plans under consideration for ACRF include: evaluating field campaigns for Twitter and microblogging opportunities, adding public discussion forums to research highlight web pages, moving existing photos into albums on FlickR or Facebook, and building online video archives through YouTube.

  7. ACRF Ingest Software Status: New, Current, and Future - April 2008

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    AS Koontz; S Choudhury; BD Ermold

    2008-04-01

    The purpose of this report is to provide status of the ingest software used to process instrument data for the Atmospheric Radiation Measurement Program Climate Research Facility (ACRF). The report is divided into 4 sections: (1) for news about ingests currently under development, (2) for current production ingests, (3) for future ingest development plans, and (4) for information on retired ingests. Please note that datastreams beginning in “xxx” indicate cases where ingests run at multiple ACRF sites, which results in a datastream(s) for each location.

  8. ACRF Ingest Software Status: New, Current, and Future (September 2007)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Koontz, AS; Choudhury, S; Ermold, BD

    2007-04-01

    The purpose of this report is to provide status of the ingest software used to process instrument data for the Atmospheric Radiation Measurement Program Climate Research Facility (ACRF). The report is divided into 4 sections: (1) for news about ingests currently under development, (2) for current production ingests, (3) for future ingest development plans, and (4) for information on retired ingests. Please note that datastreams beginning in “xxx” indicate cases where ingests run at multiple ACRF sites, which results in a datastream(s) for each location.

  9. ACRF Ingest Software Status: New, Current, and Future - May 2008

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    AS Koontz; S Choudhury; BD Ermold

    2008-05-01

    The purpose of this report is to provide status of the ingest software used to process instrument data for the Atmospheric Radiation Measurement Program Climate Research Facility (ACRF). The report is divided into 4 sections: (1) for news about ingests currently under development, (2) for current production ingests, (3) for future ingest development plans, and (4) for information on retired ingests. Please note that datastreams beginning in “xxx” indicate cases where ingests run at multiple ACRF sites, which results in a datastream(s) for each location.

  10. ACRF Instrumentation Status: New, Current, and Future - January 2008

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    AS Koontz; S Choudhury; BD Ermold

    2008-01-31

    The purpose of this report is to provide status of the ingest software used to process instrument data for the Atmospheric Radiation Measurement Program Climate Research Facility (ACRF). The report is divided into 4 sections: (1) for news about ingests currently under development, (2) for current production ingests, (3) for future ingest development plans, and (4) for information on retired ingests. Please note that datastreams beginning in “xxx” indicate cases where ingests run at multiple ACRF sites, which results in a datastream(s) for each location.

  11. ACRF Instrumentation Status: New, Current, and Future - October – November 2007

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    JW Voyles

    2007-11-30

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement (ARM) Climate Research Facility (ACRF) instrumentation status. The report is divided into the following four sections: (1) new instrumentation in the process of being acquired and deployed, (2) existing instrumentation and progress on improvements or upgrades, (3) proposed future instrumentation, and (4) SBIR instrument development.

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    AS Koontz; S Choudhury; BD Ermold

    The purpose of this report is to provide status of the ingest software used to process instrument data for the Atmospheric Radiation Measurement (ARM) Climate Research Facility (ACRF). The report is divided into four sections: (1) news about ingests currently under development, (2) current production ingests, (3) future ingest development plans, and (4) information on retired ingests. Please note that datastreams beginning in “xxx” indicate cases where ingests run at multiple ACRF sites, which results in a datastream(s) for each location.

  13. The Status of the ACRF Millimeter Wave Cloud Radars (MMCRs), the Path Forward for Future MMCR Upgrades, the Concept of 3D Volume Imaging Radar and the UAV Radar

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    P Kollias; MA Miller; KB Widener

    2005-12-30

    The United States (U.S.) Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility (ACRF) operates millimeter wavelength cloud radars (MMCRs) in several climatological regimes. The MMCRs, are the primary observing tool for quantifying the properties of nearly all radiatively important clouds over the ACRF sites. The first MMCR was installed at the ACRF Southern Great Plains (SGP) site nine years ago and its original design can be traced to the early 90s. Since then, several MMCRs have been deployed at the ACRF sites, while no significant hardware upgrades have been performed. Recently, a two-stage upgrade (first C-40 Digitalmore » Signal Processors [DSP]-based, and later the PC-Integrated Radar AcQuisition System [PIRAQ-III] digital receiver) of the MMCR signal-processing units was completed. Our future MMCR related goals are: 1) to have a cloud radar system that continues to have high reliability and uptime and 2) to suggest potential improvements that will address increased sensitivity needs, superior sampling and low cost maintenance of the MMCRs. The Traveling Wave Tube (TWT) technology, the frequency (35-GHz), the radio frequency (RF) layout, antenna, the calibration and radar control procedure and the environmental enclosure of the MMCR remain assets for our ability to detect the profile of hydrometeors at all heights in the troposphere at the ACRF sites.« less

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Koontz, AS; Choudhury, S; Ermold, BD: Gaustad, KL

    The purpose of this report is to provide status of the ingest software used to process instrument data for the Atmospheric Radiation Measurement Program Climate Research Facility (ACRF). The report is divided into 4 sections: (1) for news about ingests currently under development, (2) for current production ingests, (3) for future ingest development plans, and (4) for information on retired ingests. Please note that datastreams beginning in “xxx” indicate cases where ingests run at multiple ACRF sites, which results in a datastream(s) for each location.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    AS Koontz; S Choudhury; BD Ermold

    The purpose of this report is to provide status of the ingest software used to process instrument data for the Atmospheric Radiation Measurement (ARM) Program Climate Research Facility (ACRF). The report is divided into 4 sections: (1) for news about ingests currently under development, (2) for current production ingests, (3) for future ingest development plans, and (4) for information on retired ingests. Please note that datastreams beginning in “xxx” indicate cases where ingests run at multiple ACRF sites, which results in a datastream(s) for each location.

  16. The effects of atmospheric cloud radiative forcing on climate

    NASA Technical Reports Server (NTRS)

    Randall, David A.

    1989-01-01

    In order to isolate the effects of atmospheric cloud radiative forcing (ACRF) on climate, the general circulation of an ocean-covered earth called 'Seaworld' was simulated using the Colorado State University GCM. Most current climate models, however, do not include an interactive ocean. The key simplifications in 'Seaworld' are the fixed boundary temperature with no land points, the lack of mountains and the zonal uniformity of the boundary conditions. Two 90-day 'perpetual July' simulations were performed and analyzed the last sixty days of each. The first run included all the model's physical parameterizations, while the second omitted the effects of clouds in both the solar and terrestrial radiation parameterizations. Fixed and identical boundary temperatures were set for the two runs, and resulted in differences revealing the direct and indirect effects of the ACRF on the large-scale circulation and the parameterized hydrologic processes.

  17. Atmospheric Radiation Measurement program climate research facility operations quarterly report.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sisterson, D. L.; Decision and Information Sciences

    2006-09-06

    Individual raw data streams from instrumentation at the Atmospheric Radiation Measurement (ARM) Program Climate Research Facility (ACRF) fixed and mobile sites are collected and sent to the Data Management Facility (DMF) at Pacific Northwest National Laboratory (PNNL) for processing in near real time. Raw and processed data are then sent daily to the ACRF Archive, where they are made available to users. For each instrument, we calculate the ratio of the actual number of data records received daily at the Archive to the expected number of data records. The results are tabulated by (1) individual data stream, site, and monthmore » for the current year and (2) site and fiscal year dating back to 1998. The U.S. Department of Energy requires national user facilities to report time-based operating data. The requirements concern the actual hours of operation (ACTUAL); the estimated maximum operation or uptime goal (OPSMAX), which accounts for planned downtime; and the VARIANCE [1-(ACTUAL/OPSMAX)], which accounts for unplanned downtime. The OPSMAX time for the third quarter for the Southern Great Plains (SGP) site is 2,074.80 hours (0.95 x 2,184 hours this quarter). The OPSMAX for the North Slope Alaska (NSA) locale is 1,965.60 hours (0.90 x 2,184), and that for the Tropical Western Pacific (TWP) locale is 1,856.40 hours (0.85 x 2,184). The OPSMAX time for the ARM Mobile Facility (AMF) is 2,074.80 hours (0.95 x 2,184). The differences in OPSMAX performance reflect the complexity of local logistics and the frequency of extreme weather events. It is impractical to measure OPSMAX for each instrument or data stream. Data availability reported here refers to the average of the individual, continuous data streams that have been received by the Archive. Data not at the Archive are caused by downtime (scheduled or unplanned) of the individual instruments. Therefore, data availability is directly related to individual instrument uptime. Thus, the average percent of data in the Archive represents the average percent of the time (24 hours per day, 91 days for this quarter) the instruments were operating this quarter. Table 1 shows the accumulated maximum operation time (planned uptime), the actual hours of operation, and the variance (unplanned downtime) for the period April 1 through June 30, 2006, for the fixed and mobile sites. Although the AMF is currently up and running in Niamey, Niger, Africa, the AMF statistics are reported separately and not included in the aggregate average with the fixed sites. The third quarter comprises a total of 2,184 hours. For all fixed sites (especially the TWP locale) and the AMF, the actual data availability (and therefore actual hours of operation) exceeded the individual (and well as aggregate average of the fixed sites) operational goal for the third quarter of fiscal year (FY) 2006.« less

  18. Atmospheric Radiation Measurement program climate research facilities quarterly report April 1 - June 30, 2009.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sisterson, D. L.

    2009-07-14

    Individual raw data streams from instrumentation at the Atmospheric Radiation Measurement (ARM) Program Climate Research Facility (ACRF) fixed and mobile sites are collected and sent to the Data Management Facility (DMF) at Pacific Northwest National Laboratory (PNNL) for processing in near-real time. Raw and processed data are then sent approximately daily to the ACRF Archive, where they are made available to users. For each instrument, we calculate the ratio of the actual number of data records received daily at the archive to the expected number of data records. The results are tabulated by (1) individual data stream, site, and monthmore » for the current year and (2) site and fiscal year (FY) dating back to 1998. The U.S. Department of Energy (DOE) requires national user facilities to report time-based operating data. The requirements concern the actual hours of operation (ACTUAL); the estimated maximum operation or uptime goal (OPSMAX), which accounts for planned downtime; and the VARIANCE [1 - (ACTUAL/OPSMAX)], which accounts for unplanned downtime. The OPSMAX time for the third quarter of FY 2009 for the Southern Great Plains (SGP) site is 2,074.80 hours (0.95 x 2,184 hours this quarter); for the North Slope Alaska (NSA) locale it is 1,965.60 hours (0.90 x 2,184); and for the Tropical Western Pacific (TWP) locale it is 1,856.40 hours (0.85 x 2,184). The ARM Mobile Facility (AMF) was officially operational May 1 in Graciosa Island, the Azores, Portugal, so the OPSMAX time this quarter is 1390.80 hours (0.95 x 1464). The differences in OPSMAX performance reflect the complexity of local logistics and the frequency of extreme weather events. It is impractical to measure OPSMAX for each instrument or data stream. Data availability reported here refers to the average of the individual, continuous data streams that have been received by the Archive. Data not at the Archive are caused by downtime (scheduled or unplanned) of the individual instruments. Therefore, data availability is directly related to individual instrument uptime. Thus, the average percentage of data in the Archive represents the average percentage of the time (24 hours per day, 91 days for this quarter) the instruments were operating this quarter. Table 1 shows the accumulated maximum operation time (planned uptime), actual hours of operation, and variance (unplanned downtime) for April 1 - June 30, 2009, for the fixed sites. Because the AMF operates episodically, the AMF statistics are reported separately and are not included in the aggregate average with the fixed sites. The AMF statistics for this reporting period were not available at the time of this report. The third quarter comprises a total of 2,184 hours for the fixed sites. The average well exceeded our goal this quarter.« less

  19. Atmospheric Radiation Measurement program climate research facility operations quarterly report July 1 - Sep. 30, 2009.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sisterson, D. L.

    2009-10-15

    Individual raw data streams from instrumentation at the Atmospheric Radiation Measurement (ARM) Program Climate Research Facility (ACRF) fixed and mobile sites are collected and sent to the Data Management Facility (DMF) at Pacific Northwest National Laboratory (PNNL) for processing in near-real time. Raw and processed data are then sent approximately daily to the ACRF Archive, where they are made available to users. For each instrument, we calculate the ratio of the actual number of data records received daily at the Archive to the expected number of data records. The results are tabulated by (1) individual data stream, site, and monthmore » for the current year and (2) site and fiscal year (FY) dating back to 1998. The U.S. Department of Energy (DOE) requires national user facilities to report time-based operating data. The requirements concern the actual hours of operation (ACTUAL); the estimated maximum operation or uptime goal (OPSMAX), which accounts for planned downtime; and the VARIANCE [1 - (ACTUAL/OPSMAX)], which accounts for unplanned downtime. The OPSMAX time for the fourth quarter of FY 2009 for the Southern Great Plains (SGP) site is 2,097.60 hours (0.95 ? 2,208 hours this quarter). The OPSMAX for the North Slope Alaska (NSA) locale is 1,987.20 hours (0.90 ? 2,208) and for the Tropical Western Pacific (TWP) locale is 1,876.8 hours (0.85 ? 2,208). The ARM Mobile Facility (AMF) was officially operational May 1 in Graciosa Island, the Azores, Portugal, so the OPSMAX time this quarter is 2,097.60 hours (0.95 x 2,208). The differences in OPSMAX performance reflect the complexity of local logistics and the frequency of extreme weather events. It is impractical to measure OPSMAX for each instrument or data stream. Data availability reported here refers to the average of the individual, continuous data streams that have been received by the Archive. Data not at the Archive result from downtime (scheduled or unplanned) of the individual instruments. Therefore, data availability is directly related to individual instrument uptime. Thus, the average percentage of data in the Archive represents the average percentage of the time (24 hours per day, 92 days for this quarter) the instruments were operating this quarter. Table 1 shows the accumulated maximum operation time (planned uptime), actual hours of operation, and variance (unplanned downtime) for the period July 1 - September 30, 2009, for the fixed sites. Because the AMF operates episodically, the AMF statistics are reported separately and not included in the aggregate average with the fixed sites. The fourth quarter comprises a total of 2,208 hours for the fixed and mobile sites. The average of the fixed sites well exceeded our goal this quarter. The AMF data statistic requires explanation. Since the AMF radar data ingest software is being modified, the data are being stored in the DMF for data processing. Hence, the data are not at the Archive; they are anticipated to become available by the next report.« less

  20. Validation of aerosol extinction and water vapor profiles from routine Atmospheric Radiation Measurement Program Climate Research Facility measurements

    NASA Astrophysics Data System (ADS)

    Schmid, Beat; Flynn, Connor J.; Newsom, Rob K.; Turner, David D.; Ferrare, Richard A.; Clayton, Marian F.; Andrews, Elisabeth; Ogren, John A.; Johnson, Roy R.; Russell, Philip B.; Gore, Warren J.; Dominguez, Roseanne

    2009-11-01

    The accuracy with which vertical profiles of aerosol extinction σep(λ) can be measured using routine Atmospheric Radiation Measurement Program (ARM) Climate Research Facility (ACRF) measurements and was assessed using data from two airborne field campaigns, the ARM Aerosol Intensive Operation Period (AIOP, May 2003), and the Aerosol Lidar Validation Experiment (ALIVE, September 2005). This assessment pertains to the aerosol at its ambient concentration and thermodynamic state (i.e., σep(λ) either free of or corrected for sampling artifacts) and includes the following ACRF routine methods: Raman lidar, micropulse lidar (MPL), and in situ aerosol profiles (IAP) with a small aircraft. Profiles of aerosol optical depth τp(λ), from which the profiles of σep(λ) are derived through vertical differentiation, were measured by the NASA Ames Airborne Tracking 14-channel Sun photometer (AATS-14); these data were used as benchmark in this evaluation. The ACRF IAP σep(550 nm) were lower by 11% (during AIOP) and higher by 1% (during ALIVE) when compared to AATS-14. The ACRF MPL σep(523 nm) measurements were higher by 24% (AIOP) and 19-21% (ALIVE) compared to AATS-14, but the correlation improved significantly during ALIVE. In the AIOP, a second MPL operated by NASA showed a smaller positive bias (13%) with respect to AATS-14. The ACRF Raman lidar σep(355 nm) measurements were larger by 54% (AIOP) and by 6% (ALIVE) compared to AATS-14. The large bias in the Raman lidar measurements during AIOP stemmed from a gradual loss of Raman lidar sensitivity starting about the end of 2001 going unnoticed until after AIOP. A major refurbishment and upgrade of the instrument and improvements to a data processing algorithm led to the significant improvement and very small bias in ALIVE. Finally, we find that during ALIVE the Raman lidar water vapor densities ρw are 8% larger when compared to AATS-14, whereas in situ measured ρw aboard two different aircraft are smaller than the AATS-14 values by 0.3-3%.

  1. The effects of cloud radiative forcing on an ocean-covered planet

    NASA Technical Reports Server (NTRS)

    Randall, David A.

    1990-01-01

    Cumulus anvil clouds, whose importance has been emphasized by observationalists in recent years, exert a very powerful influence on deep tropical convection by tending to radiatively destabilize the troposphere. In addition, they radiatively warm the column in which they reside. Their strong influence on the simulated climate argues for a much more refined parameterization in the General Circulation Model (GCM). For Seaworld, the atmospheric cloud radiative forcing (ACRF) has a powerful influence on such basic climate parameters as the strength of the Hadley circulation, the existence of a single narrow InterTropical Convergence Zone (ITCZ), and the precipitable water content of the atmosphere. It seems likely, however, that in the real world the surface CRF feeds back negatively to suppress moist convection and the associated cloudiness, and so tends to counteract the effects of the ACRF. Many current climate models have fixed sea surface temperatures but variable land-surface temperatures. The tropical circulations of such models may experience a position feedback due to ACRF over the oceans, and a negative or weak feedback due to surface CRF over the land. The overall effects of the CRF on the climate system can only be firmly established through much further analysis, which can benefit greatly from the use of a coupled ocean-atmospheric model.

  2. Atmospheric Radiation Measurement program climate research facility operations quarterly report October 1 - December 31, 2008.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sisterson, D. L.

    2009-01-15

    Individual raw data streams from instrumentation at the Atmospheric Radiation Measurement (ARM) Program Climate Research Facility (ACRF) fixed and mobile sites are collected and sent to the Data Management Facility (DMF) at Pacific Northwest National Laboratory (PNNL) for processing in near real-time. Raw and processed data are then sent daily to the ACRF Archive, where they are made available to users. For each instrument, they calculate the ratio of the actual number of data records received daily at the Archive to the expected number of data records. The results are tabulated by (1) individual data stream, site, and month formore » the current year and (2) site and fiscal year (FY) dating back to 1998. The US Department of Energy (DOE) requires national user facilities to report time-based operating data. The requirements concern the actual hours of operation (ACTUAL); the estimated maximum operation or uptime goal (OPSMAX), which accounts for planned downtime; and the VARIANCE [1-(ACTUAL/OPSMAX)], which accounts for unplanned downtime. The OPSMAX time for the first quarter of FY 2009 for the Southern Great Plains (SGP) site is 2,097.60 hours (0.95 x 2,208 hours this quarter). The OPSMAX for the North Slope Alaska (NSA) locale is 1,987.20 hours (0.90 x 2,208), and for the Tropical Western Pacific (TWP) locale is 1,876.80 hours (0.85 x 2,208). The OPSMAX time for the ARM Mobile Facility (AMF) is not reported this quarter because the data have not yet been released from China to the DMF for processing. The differences in OPSMAX performance reflect the complexity of local logistics and the frequency of extreme weather events. It is impractical to measure OPSMAX for each instrument or data stream. Data availability reported here refers to the average of the individual, continuous data streams that have been received by the Archive. Data not at the Archive are caused by downtime (scheduled or unplanned) of the individual instruments. Therefore, data availability is directly related to individual instrument uptime. Thus, the average percentage of data in the Archive represents the average percentage of the time (24 hours per day, 92 days for this quarter) the instruments were operating this quarter. Table 1 shows the accumulated maximum operation time (planned uptime), actual hours of operation, and variance (unplanned downtime) for the period October 1-December 31, 2008, for the fixed sites. The AMF has been deployed to China, but the data have not yet been released. The first quarter comprises a total of 2,208 hours. The average exceeded their goal this quarter.« less

  3. Atmospheric Radiation Measurement program climate research facility operations quarterly report January 1 - March 31, 2009.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sisterson, D. L.

    2009-04-23

    Individual raw data streams from instrumentation at the Atmospheric Radiation Measurement (ARM) Program Climate Research Facility (ACRF) fixed and mobile sites are collected and sent to the Data Management Facility (DMF) at Pacific Northwest National Laboratory (PNNL) for processing in near real-time. Raw and processed data are then sent daily to the ACRF Archive, where they are made available to users. For each instrument, we calculate the ratio of the actual number of data records received daily at the Archive to the expected number of data records. The results are tabulated by (1) individual data stream, site, and month formore » the current year and (2) site and fiscal year (FY) dating back to 1998. The U.S. Department of Energy (DOE) requires national user facilities to report time-based operating data. The requirements concern the actual hours of operation (ACTUAL); the estimated maximum operation or uptime goal (OPSMAX), which accounts for planned downtime; and the VARIANCE [1 - (ACTUAL/OPSMAX)], which accounts for unplanned downtime. The OPSMAX time for the second quarter of FY 2009 for the Southern Great Plains (SGP) site is 2,052.00 hours (0.95 x 2,160 hours this quarter). The OPSMAX for the North Slope Alaska (NSA) locale is 1,944.00 hours (0.90 x 2,160), and for the Tropical Western Pacific (TWP) locale is 1,836.00 hours (0.85 x 2,160). The OPSMAX time for the ARM Mobile Facility (AMF) is not reported this quarter because not all of the metadata have been acquired that are used to generate this metric. The differences in OPSMAX performance reflect the complexity of local logistics and the frequency of extreme weather events. It is impractical to measure OPSMAX for each instrument or data stream. Data availability reported here refers to the average of the individual, continuous data streams that have been received by the Archive. Data not at the Archive are caused by downtime (scheduled or unplanned) of the individual instruments. Therefore, data availability is directly related to individual instrument uptime. Thus, the average percentage of data in the Archive represents the average percentage of the time (24 hours per day, 90 days for this quarter) the instruments were operating this quarter. Summary. Table 1 shows the accumulated maximum operation time (planned uptime), actual hours of operation, and variance (unplanned downtime) for the period January 1 - March 31, 2009, for the fixed sites. The AMF has completed its mission in China but not all of the data can be released to the public at the time of this report. The second quarter comprises a total of 2,160 hours. The average exceeded our goal this quarter.« less

  4. Tools for Teaching Climate Change Studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maestas, A.M.; Jones, L.A.

    2005-03-18

    The Atmospheric Radiation Measurement Climate Research Facility (ACRF) develops public outreach materials and educational resources for schools. Studies prove that science education in rural and indigenous communities improves when educators integrate regional knowledge of climate and environmental issues into school curriculum and public outreach materials. In order to promote understanding of ACRF climate change studies, ACRF Education and Outreach has developed interactive kiosks about climate change for host communities close to the research sites. A kiosk for the North Slope of Alaska (NSA) community was installed at the Iupiat Heritage Center in 2003, and a kiosk for the Tropical Westernmore » Pacific locales will be installed in 2005. The kiosks feature interviews with local community elders, regional agency officials, and Atmospheric Radiation Measurement (ARM) Program scientists, which highlight both research and local observations of some aspects of environmental and climatic change in the Arctic and Pacific. The kiosks offer viewers a unique opportunity to learn about the environmental concerns and knowledge of respected community elders, and to also understand state-of-the-art climate research. An archive of interviews from the communities will also be distributed with supplemental lessons and activities to encourage teachers and students to compare and contrast climate change studies and oral history observations from two distinct locations. The U.S. Department of Energy's ACRF supports education and outreach efforts for communities and schools located near its sites. ACRF Education and Outreach has developed interactive kiosks at the request of the communities to provide an opportunity for the public to learn about climate change from both scientific and indigenous perspectives. Kiosks include interviews with ARM scientists and provide users with basic information about climate change studies as well as interviews with elders and community leaders discussing the impacts of climate change on land, sea, and other aspects of village life.« less

  5. Atmospheric Radiation Measurement Program Climate Research Facility Operations Quarterly Report July 1 – September 30, 2008

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sisterson, DL

    2008-09-30

    Individual raw data streams from instrumentation at the Atmospheric Radiation Measurement (ARM) Program Climate Research Facility (ACRF) fixed and mobile sites are collected and sent to the Data Management Facility (DMF) at Pacific Northwest National Laboratory (PNNL) for processing in near real-time. Raw and processed data are then sent daily to the ACRF Archive, where they are made available to users. For each instrument, we calculate the ratio of the actual number of data records received daily at the Archive to the expected number of data records. The results are tabulated by (1) individual data stream, site, and month formore » the current year and (2) site and fiscal year (FY) dating back to 1998. The U.S. Department of Energy (DOE) requires national user facilities to report time-based operating data. The requirements concern the actual hours of operation (ACTUAL); the estimated maximum operation or uptime goal (OPSMAX), which accounts for planned downtime; and the VARIANCE [1 – (ACTUAL/OPSMAX)], which accounts for unplanned downtime. The OPSMAX time for the fourth quarter of FY 2008 for the Southern Great Plains (SGP) site is 2,097.60 hours (0.95 x 2,208 hours this quarter). The OPSMAX for the North Slope Alaska (NSA) locale is 1,987.20 hours (0.90 x 2,208), and for the Tropical Western Pacific (TWP) locale is 1,876.80 hours (0.85 x 2,208). The OPSMAX time for the ARM Mobile Facility (AMF) is not reported this quarter because the data have not yet been released from China to the DMF for processing. The differences in OPSMAX performance reflect the complexity of local logistics and the frequency of extreme weather events. It is impractical to measure OPSMAX for each instrument or data stream. Data availability reported here refers to the average of the individual, continuous data streams that have been received by the Archive. Data not at the Archive are caused by downtime (scheduled or unplanned) of the individual instruments. Therefore, data availability is directly related to individual instrument uptime. Thus, the average percentage of data in the Archive represents the average percentage of the time (24 hours per day, 92 days for this quarter) the instruments were operating this quarter.« less

  6. Atmospheric Radiation Measurement program climate research facility operations quarterly report April 1 - June 30, 2007.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sisterson, D. L.

    2007-07-26

    Individual raw data streams from instrumentation at the Atmospheric Radiation Measurement (ARM) Program Climate Research Facility (ACRF) fixed and mobile sites are collected and sent to the Data Management Facility (DMF) at Pacific Northwest National Laboratory (PNNL) for processing in near real time. Raw and processed data are then sent daily to the ACRF Archive, where they are made available to users. For each instrument, we calculate the ratio of the actual number of data records received daily at the Archive to the expected number of data records. The results are tabulated by (1) individual data stream, site, and monthmore » for the current year and (2) site and fiscal year (FY) dating back to 1998. The U.S. Department of Energy requires national user facilities to report time-based operating data. The requirements concern the actual hours of operation (ACTUAL); the estimated maximum operation or uptime goal (OPSMAX), which accounts for planned downtime; and the VARIANCE [1 - (ACTUAL/OPSMAX)], which accounts for unplanned downtime. The OPSMAX time for the third quarter of FY 2007 for the Southern Great Plains (SGP) site is 2,074.8 hours (0.95 x 2,184 hours this quarter). The OPSMAX for the North Slope Alaska (NSA) locale is 1,965.6 hours (0.90 x 2,184), and that for the Tropical Western Pacific (TWP) locale is 1,856.4 hours (0.85 x 2,184). The OPSMAX time for the ARM Mobile Facility (AMF) is 2,074.8 hours (0.95 x 2,184). The differences in OPSMAX performance reflect the complexity of local logistics and the frequency of extreme weather events. It is impractical to measure OPSMAX for each instrument or data stream. Data availability reported here refers to the average of the individual, continuous data streams that have been received by the Archive. Data not at the Archive are caused by downtime (scheduled or unplanned) of the individual instruments. Therefore, data availability is directly related to individual instrument uptime. Thus, the average percent of data in the Archive represents the average percent of the time (24 hours per day, 91 days for this quarter) the instruments were operating this quarter. Table 1 shows the accumulated maximum operation time (planned uptime), the actual hours of operation, and the variance (unplanned downtime) for the period April 1 through June 30, 2007, for the fixed sites only. The AMF has been deployed to Germany and is operational this quarter. The third quarter comprises a total of 2,184 hours. Although the average exceeded our goal this quarter, there were cash flow issues resulting from Continuing Resolution early in the period that did not allow for timely instrument repairs that kept our statistics lower than past quarters at all sites. The low NSA numbers resulted from missing MFRSR data this spring that appears to be recoverable but not available at the Archive at the time of this report.« less

  7. Interactions among Radiation, Convection, and Large-Scale Dynamics in a General Circulation Model.

    NASA Astrophysics Data System (ADS)

    Randall, David A.; Harshvardhan; Dazlich, Donald A.; Corsetti, Thomas G.

    1989-07-01

    We have analyzed the effects of radiatively active clouds on the climate simulated by the UCLA/GLA GCM, with particular attention to the effects of the upper tropospheric stratiform clouds associated with deep cumulus convection, and the interactions of these clouds with convection and the large-scale circulation.Several numerical experiments have been performed to investigate the mechanisms through which the clouds influence the large-scale circulation. In the `NODETLQ' experiment, no liquid water or ice was detrained from cumulus clouds into the environment; all of the condensate was rained out. Upper level supersaturation cloudiness was drastically reduced, the atmosphere dried, and tropical outgoing longwave radiation increased. In the `NOANVIL' experiment, the radiative effects of the optically thich upper-level cloud sheets associated with deep cumulus convection were neglected. The land surface received more solar radiation in regions of convection, leading to enhanced surface fluxes and a dramatic increase in precipitation. In the `NOCRF' experiment, the longwave atmospheric cloud radiative forcing (ACRF) was omitted, paralleling the recent experiment of Slingo and Slingo. The results suggest that the ACRF enhances deep penetrative convection and precipitation, while suppressing shallow convection. They also indicate that the ACRF warms and moistens the tropical troposphere. The results of this experiment are somewhat ambiguous, however; for example, the ACRF suppresses precipitation in some parts of the tropics, and enhances it in others.To isolate the effects of the ACRF in a simpler setting, we have analyzed the climate of an ocean-covered Earth, which we call Seaworld. The key simplicities of Seaworld are the fixed boundary temperature with no land points, the lack of mountains, and the zonal uniformity of the boundary conditions. Results are presented from two Seaworld simulations. The first includes a full suite of physical parameterizations, while the second omits all radiative effects of the clouds. The differences between the two runs are, therefore, entirely due to the direct and indirect and indirect effects of the ACRF. Results show that the ACRF in the cloudy run accurately represents the radiative heating perturbation relative to the cloud-free run. The cloudy run is warmer in the middle troposphere, contains much more precipitable water, and has about 15% more globally averaged precipitation. There is a double tropical rain band in the cloud-free run, and a single, more intense tropical rain band in the cloudy run. The cloud-free run produces relatively weak but frequent cumulus convection, while the cloudy run produces relatively intense but infrequent convection. The mean meridional circulation transport nearly twice as much mass in the cloudy run. The increased tropical rising motion in the cloudy run leads to a deeper boundary layer and also to more moisture in the troposphere above the boundary layer. This accounts for the increased precipitable water content of the atmosphere. The clouds lead to an increase in the intensity of the tropical easterlies, and cause the midlatitude westerly jets to shift equatorward.Taken together, our results show that upper tropospheric clouds associated with moist convection, whose importance has recently been emphasized in observational studies, play a very complex and powerful role in determining the model results. This points to a need to develop more realistic parameterizations of these clouds.

  8. High-NaCl diet impairs dynamic renal blood flow autoregulation in rats with adenine-induced chronic renal failure.

    PubMed

    Saeed, Aso; DiBona, Gerald F; Grimberg, Elisabeth; Nguy, Lisa; Mikkelsen, Minne Line Nedergaard; Marcussen, Niels; Guron, Gregor

    2014-03-15

    This study examined the effects of 2 wk of high-NaCl diet on kidney function and dynamic renal blood flow autoregulation (RBFA) in rats with adenine-induced chronic renal failure (ACRF). Male Sprague-Dawley rats received either chow containing adenine or were pair-fed an identical diet without adenine (controls). After 10 wk, rats were randomized to either remain on the same diet (0.6% NaCl) or to be switched to high 4% NaCl chow. Two weeks after randomization, renal clearance experiments were performed under isoflurane anesthesia and dynamic RBFA, baroreflex sensitivity (BRS), systolic arterial pressure variability (SAPV), and heart rate variability were assessed by spectral analytical techniques. Rats with ACRF showed marked reductions in glomerular filtration rate and renal blood flow (RBF), whereas mean arterial pressure and SAPV were significantly elevated. In addition, spontaneous BRS was reduced by ∼50% in ACRF animals. High-NaCl diet significantly increased transfer function fractional gain values between arterial pressure and RBF in the frequency range of the myogenic response (0.06-0.09 Hz) only in ACRF animals (0.3 ± 4.0 vs. -4.4 ± 3.8 dB; P < 0.05). Similarly, a high-NaCl diet significantly increased SAPV in the low-frequency range only in ACRF animals. To conclude, a 2-wk period of a high-NaCl diet in ACRF rats significantly impaired dynamic RBFA in the frequency range of the myogenic response and increased SAPV in the low-frequency range. These abnormalities may increase the susceptibility to hypertensive end-organ injury and progressive renal failure by facilitating pressure transmission to the microvasculature.

  9. Using Radar, Lidar, and Radiometer measurements to Classify Cloud Type and Study Middle-Level Cloud Properties

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Zhien

    2010-06-29

    The project is mainly focused on the characterization of cloud macrophysical and microphysical properties, especially for mixed-phased clouds and middle level ice clouds by combining radar, lidar, and radiometer measurements available from the ACRF sites. First, an advanced mixed-phase cloud retrieval algorithm will be developed to cover all mixed-phase clouds observed at the ACRF NSA site. The algorithm will be applied to the ACRF NSA observations to generate a long-term arctic mixed-phase cloud product for model validations and arctic mixed-phase cloud processes studies. To improve the representation of arctic mixed-phase clouds in GCMs, an advanced understanding of mixed-phase cloud processesmore » is needed. By combining retrieved mixed-phase cloud microphysical properties with in situ data and large-scale meteorological data, the project aim to better understand the generations of ice crystals in supercooled water clouds, the maintenance mechanisms of the arctic mixed-phase clouds, and their connections with large-scale dynamics. The project will try to develop a new retrieval algorithm to study more complex mixed-phase clouds observed at the ACRF SGP site. Compared with optically thin ice clouds, optically thick middle level ice clouds are less studied because of limited available tools. The project will develop a new two wavelength radar technique for optically thick ice cloud study at SGP site by combining the MMCR with the W-band radar measurements. With this new algorithm, the SGP site will have a better capability to study all ice clouds. Another area of the proposal is to generate long-term cloud type classification product for the multiple ACRF sites. The cloud type classification product will not only facilitates the generation of the integrated cloud product by applying different retrieval algorithms to different types of clouds operationally, but will also support other research to better understand cloud properties and to validate model simulations. The ultimate goal is to improve our cloud classification algorithm into a VAP.« less

  10. Contributions of the Atmospheric Radiation Measurement (ARM) Program and the ARM Climate Research Facility to the U.S. Climate Change Science Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    SA Edgerton; LR Roeder

    The Earth’s surface temperature is determined by the balance between incoming solar radiation and thermal (or infrared) radiation emitted by the Earth back to space. Changes in atmospheric composition, including greenhouse gases, clouds, and aerosols can alter this balance and produce significant climate change. Global climate models (GCMs) are the primary tool for quantifying future climate change; however, there remain significant uncertainties in the GCM treatment of clouds, aerosol, and their effects on the Earth’s energy balance. The 2007 assessment (AR4) by the Intergovernmental Panel on Climate Change (IPCC) reports a substantial range among GCMs in climate sensitivity to greenhousemore » gas emissions. The largest contributor to this range lies in how different models handle changes in the way clouds absorb or reflect radiative energy in a changing climate (Solomon et al. 2007). In 1989, the U.S. Department of Energy (DOE) Office of Science created the Atmospheric Radiation Measurement (ARM) Program within the Office of Biological and Environmental Research (BER) to address scientific uncertainties related to global climate change, with a specific focus on the crucial role of clouds and their influence on the transfer of radiation in the atmosphere. To address this problem, BER has adopted a unique two-pronged approach: * The ARM Climate Research Facility (ACRF), a scientific user facility for obtaining long-term measurements of radiative fluxes, cloud and aerosol properties, and related atmospheric characteristics in diverse climate regimes. * The ARM Science Program, focused on the analysis of ACRF data to address climate science issues associated with clouds, aerosols, and radiation, and to improve GCMs. This report describes accomplishments of the BER ARM Program toward addressing the primary uncertainties related to climate change prediction as identified by the IPCC.« less

  11. Anharmonic vibrational analysis of s-trans and s-cis conformers of acryloyl fluoride using numerical-analytic Van Vleck operator perturbation theory

    NASA Astrophysics Data System (ADS)

    Krasnoshchekov, Sergey V.; Craig, Norman C.; Koroleva, Lidiya A.; Stepanov, Nikolay F.

    2018-01-01

    A new gas-phase infrared (IR) spectrum of acryloyl fluoride (ACRF, CH2dbnd CHsbnd CFdbnd O) with a resolution of 0.1 cm- 1 in the range 4000-450 cm- 1 was measured. Theoretical ab initio molecular structures, full quartic potential energy surfaces (PES), and cubic surfaces of dipole moments and polarizability tensor components (electro-optical properties, EOP) of the s-trans and s-cis conformers of the ACRF were calculated by the second-order Møller-Plesset electronic perturbation theory with a correlation consistent Dunning triple-ζ basis set. The numerical-analytic implementation of the second-order operator canonical Van Vleck perturbation theory was employed for predicting anharmonic IR and Raman scattering (RS) spectra of ACRF. To improve the anharmonic predictions, harmonic frequencies were replaced by their counterparts evaluated with the higher-level CCSD(T)/cc-pVTZ model, to form a ;hybrid; PES. The original operator representation of the Hamiltonian is analytically reduced to a quasi-diagonal form, integrated in the harmonic oscillator basis and diagonalized to account for strong resonance couplings. Double canonical transformations of EOP expansions enabled prediction of integral intensities of both fundamental and multi-quanta transitions in IR/RS spectra. Enhanced band shape analysis reinforced the assignments. A thorough interpretation of the new IR experimental spectra and existing matrix-isolation literature data for the mixture of two conformers of ACRF was accomplished, and a number of assignments clarified.

  12. MWRRET Value-Added Product: The Retrieval of Liquid Water Path and Precipitable Water Vapor from Microwave Radiometer (MWR) Datasets May 2009

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gaustad, KL; Turner, DD

    2009-05-30

    This report provides a short description of the Atmospheric Radiation Measurement (ARM) Climate Research Facility (ACRF) microwave radiometer (MWR) RETrievel (MWRRET) value-added product (VAP) algorithm. This algorithm utilizes a complementary physical retrieval method and applies brightness temperature offsets to reduce spurious liquid water path (LWP) bias in clear skies resulting in significantly improved precipitable water vapor (PWV) and LWP retrievals. We present a general overview of the technique, input parameters, output products, and describe data quality checks. A more complete discussion of the theory and results is given in Turner et al. (2007b).

  13. Evaluating cloud retrieval algorithms with the ARM BBHRP framework

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mlawer,E.; Dunn,M.; Mlawer, E.

    2008-03-10

    Climate and weather prediction models require accurate calculations of vertical profiles of radiative heating. Although heating rate calculations cannot be directly validated due to the lack of corresponding observations, surface and top-of-atmosphere measurements can indirectly establish the quality of computed heating rates through validation of the calculated irradiances at the atmospheric boundaries. The ARM Broadband Heating Rate Profile (BBHRP) project, a collaboration of all the working groups in the program, was designed with these heating rate validations as a key objective. Given the large dependence of radiative heating rates on cloud properties, a critical component of BBHRP radiative closure analysesmore » has been the evaluation of cloud microphysical retrieval algorithms. This evaluation is an important step in establishing the necessary confidence in the continuous profiles of computed radiative heating rates produced by BBHRP at the ARM Climate Research Facility (ACRF) sites that are needed for modeling studies. This poster details the continued effort to evaluate cloud property retrieval algorithms within the BBHRP framework, a key focus of the project this year. A requirement for the computation of accurate heating rate profiles is a robust cloud microphysical product that captures the occurrence, height, and phase of clouds above each ACRF site. Various approaches to retrieve the microphysical properties of liquid, ice, and mixed-phase clouds have been processed in BBHRP for the ACRF Southern Great Plains (SGP) and the North Slope of Alaska (NSA) sites. These retrieval methods span a range of assumptions concerning the parameterization of cloud location, particle density, size, shape, and involve different measurement sources. We will present the radiative closure results from several different retrieval approaches for the SGP site, including those from Microbase, the current 'reference' retrieval approach in BBHRP. At the NSA, mixed-phase clouds and cloud with a low optical depth are prevalent; the radiative closure studies using Microbase demonstrated significant residuals. As an alternative to Microbase at NSA, the Shupe-Turner cloud property retrieval algorithm, aimed at improving the partitioning of cloud phase and incorporating more constrained, conditional microphysics retrievals, also has been evaluated using the BBHRP data set.« less

  14. Nauru Island Effect Detection Data Set

    DOE Data Explorer

    Long, Chuck

    2010-07-15

    During Nauru99 it was noted that the island was producing small clouds that advected over the ARM site. The Nauru Island Effect Study was run for 1.5 years and the methodology developed to detect the occurrence. Nauru ACRF downwelling SW, wind direction, and air temperature data are used, along with downwelling SW data from Licor radiometers located on the southern end of the island near the airport landing strip. A statistical analysis and comparison of data from the two locations is used to detect the likely occurrence of an island influence on the Nauru ACRF site data

  15. CRISPR RNA and anti-CRISPR protein binding to the Xanthomonas albilineans Csy1-Csy2 heterodimer in the type I-F CRISPR-Cas system.

    PubMed

    Hong, Suji; Ka, Donghyun; Yoon, Seo Jeong; Suh, Nayoung; Jeong, Migyeong; Suh, Jeong-Yong; Bae, Euiyoung

    2018-02-23

    Clustered regularly interspaced short palindromic repeats (CRISPRs) and CRISPR-associated (Cas) proteins provide microbial adaptive immunity against bacteriophages. In type I-F CRISPR-Cas systems, multiple Cas proteins (Csy1-4) compose a surveillance complex (Csy complex) with CRISPR RNA (crRNA) for target recognition. Here, we report the biochemical characterization of the Csy1-Csy2 subcomplex from Xanthomonas albilineans , including the analysis of its interaction with crRNA and AcrF2, an anti-CRISPR (Acr) protein from a phage that infects Pseudomonas aeruginosa The X. albilineans Csy1 and Csy2 proteins (XaCsy1 and XaCsy2, respectively) formed a stable heterodimeric complex that specifically bound the 8-nucleotide (nt) 5'-handle of the crRNA. In contrast, the XaCsy1-XaCsy2 heterodimer exhibited reduced affinity for the 28-nt X. albilineans CRISPR repeat RNA containing the 5'-handle sequence. Chromatographic and calorimetric analyses revealed tight binding between the Acr protein from the P. aeruginosa phage and the heterodimeric subunit of the X. albilineans Csy complex, suggesting that AcrF2 recognizes conserved features of Csy1-Csy2 heterodimers. We found that neither XaCsy1 nor XaCsy2 alone forms a stable complex with AcrF2 and the 5'-handle RNA, indicating that XaCsy1-XaCsy2 heterodimerization is required for binding them. We also solved the crystal structure of AcrF2 to a resolution of 1.34 Å, enabling a more detailed structural analysis of the residues involved in the interactions with the Csy1-Csy2 heterodimer. Our results provide information about the order of events during the formation of the multisubunit crRNA-guided surveillance complex and suggest that the Acr protein inactivating type I-F CRISPR-Cas systems has broad specificity. © 2018 by The American Society for Biochemistry and Molecular Biology, Inc.

  16. A Climatology of Fair-Weather Cloud Statistics at the Atmospheric Radiation Measurement Program Southern Great Plains Site: Temporal and Spatial Variability

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Berg, Larry K.; Kassianov, Evgueni I.; Long, Charles N.

    2006-03-30

    In previous work, Berg and Stull (2005) developed a new parameterization for Fair-Weather Cumuli (FWC). Preliminary testing of the new scheme used data collected during a field experiment conducted during the summer of 1996. This campaign included a few research flights conducted over three locations within the Atmospheric Radiation Measurement (ARM) Climate Research Facility (ACRF) Southern Great Plains (SGP) site. A more comprehensive verification of the new scheme requires a detailed climatology of FWC. Several cloud climatologies have been completed for the ACRF SGP, but these efforts have focused on either broad categories of clouds grouped by height and seasonmore » (e.g., Lazarus et al. 1999) or height and time of day (e.g., Dong et al. 2005). In these two examples, the low clouds were not separated by the type of cloud, either stratiform or cumuliform, nor were the horizontal chord length (the length of the cloud slice that passed directly overhead) or cloud aspect ratio (defined as the ratio of the cloud thickness to the cloud chord length) reported. Lane et al. (2002) presented distributions of cloud chord length, but only for one year. The work presented here addresses these shortcomings by looking explicitly at cases with FWC over five summers. Specifically, we will address the following questions: •Does the cloud fraction (CF), cloud-base height (CBH), and cloud-top height (CTH) of FWC change with the time of day or the year? •What is the distribution of FWC chord lengths? •Is there a relationship between the cloud chord length and the cloud thickness?« less

  17. Niamey Aerosol Optical Depths

    DOE Data Explorer

    Flynn, Connor

    2008-10-01

    MFRSR irradiance data collected during the ACRF AMF deployment in Niamey, Niger have been used to derive AOD for five wavelength channels of the MFRSR. These data have been corrected to adjust for filter drift over the course of the campaign and contamination due to forward scattering as a result of large dust particles in the atmosphere around Niamey.

  18. Fine-scale Horizontal Structure of Arctic Mixed-Phase Clouds.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rambukkange,M.; Verlinde, J.; Elorante, E.

    2006-07-10

    Recent in situ observations in stratiform clouds suggest that mixed phase regimes, here defined as limited cloud volumes containing both liquid and solid water, are constrained to narrow layers (order 100 m) separating all-liquid and fully glaciated volumes (Hallett and Viddaurre, 2005). The Department of Energy Atmospheric Radiation Measurement Program's (DOE-ARM, Ackerman and Stokes, 2003) North Slope of Alaska (NSA) ARM Climate Research Facility (ACRF) recently started collecting routine measurement of radar Doppler velocity power spectra from the Millimeter Cloud Radar (MMCR). Shupe et al. (2004) showed that Doppler spectra has potential to separate the contributions to the total reflectivitymore » of the liquid and solid water in the radar volume, and thus to investigate further Hallett and Viddaurre's findings. The Mixed-Phase Arctic Cloud Experiment (MPACE) was conducted along the NSA to investigate the properties of Arctic mixed phase clouds (Verlinde et al., 2006). We present surface based remote sensing data from MPACE to discuss the fine-scale structure of the mixed-phase clouds observed during this experiment.« less

  19. Improved Estimates of Moments and Winds from Radar Wind Profiler

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Helmus, Jonathan; Ghate, Virendra P.

    2017-01-02

    The U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility (ACRF) operates nine radar wind profilers (RWP) across its sites. These RWPs operate at 915 MHz or 1290 MHz frequency and report the first three moments of the Doppler spectrum. The operational settings of the RWP were modified in summer, 2015 to have single pulse length setting for the wind mode and two pulse length settings for the precipitation mode. The moments data collected during the wind mode are used to retrieve horizontal winds. The vendor-reported winds are available at variable time resolution (10 mins, 60 mins,more » etc.) and contain a significant amount of contamination due to noise and clutter. In this data product we have recalculated the moments and the winds from the raw radar Doppler spectrum and have made efforts to mitigate the contamination due to instrument noise in the wind estimates. Additionally, the moments and wind data has been reported in a harmonized layout identical for all locations and sites.« less

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Damao; Wang, Zhien; Heymsfield, Andrew J.

    Measurement of ice number concentration in clouds is important but still challenging. Stratiform mixed-phase clouds (SMCs) provide a simple scenario for retrieving ice number concentration from remote sensing measurements. The simple ice generation and growth pattern in SMCs offers opportunities to use cloud radar reflectivity (Ze) measurements and other cloud properties to infer ice number concentration quantitatively. To understand the strong temperature dependency of ice habit and growth rate quantitatively, we develop a 1-D ice growth model to calculate the ice diffusional growth along its falling trajectory in SMCs. The radar reflectivity and fall velocity profiles of ice crystals calculatedmore » from the 1-D ice growth model are evaluated with the Atmospheric Radiation Measurements (ARM) Climate Research Facility (ACRF) ground-based high vertical resolution radar measurements. Combining Ze measurements and 1-D ice growth model simulations, we develop a method to retrieve the ice number concentrations in SMCs at given cloud top temperature (CTT) and liquid water path (LWP). The retrieved ice concentrations in SMCs are evaluated with in situ measurements and with a three-dimensional cloud-resolving model simulation with a bin microphysical scheme. These comparisons show that the retrieved ice number concentrations are within an uncertainty of a factor of 2, statistically.« less

  1. Risk factors for acute chemical releases with public health consequences: Hazardous Substances Emergency Events Surveillance in the U.S., 1996–2001

    PubMed Central

    Ruckart, Perri Z; Wattigney, Wendy A; Kaye, Wendy E

    2004-01-01

    Background Releases of hazardous materials can cause substantial morbidity and mortality. To reduce and prevent the public health consequences (victims or evacuations) from uncontrolled or illegally released hazardous substances, a more comprehensive analysis is needed to determine risk factors for hazardous materials incidents. Methods Hazardous Substances Emergency Events Surveillance (HSEES) data from 1996 through 2001 were analyzed using bivariate and multiple logistic regression. Fixed-facility and transportation-related events were analyzed separately. Results For fixed-facility events, 2,327 (8%) resulted in at least one victim and 2,844 (10%) involved ordered evacuations. For transportation-related events, 759 (8%) resulted in at least one victim, and 405 (4%) caused evacuation orders. Fire and/or explosion were the strongest risk factors for events involving either victims or evacuations. Stratified analysis of fixed-facility events involving victims showed a strong association for acid releases in the agriculture, forestry, and fisheries industry. Chlorine releases in fixed-facility events resulted in victims and evacuations in more industry categories than any other substance. Conclusions Outreach efforts should focus on preventing and preparing for fires and explosions, acid releases in the agricultural industry, and chlorine releases in fixed facilities. PMID:15496226

  2. Fixed-facility workplace screening mammography.

    PubMed

    Reynolds, H E; Larkin, G N; Jackson, V P; Hawes, D R

    1997-02-01

    Potential barriers to compliance with screening mammography guidelines include the cost and inconvenience involved with undergoing the procedure. Workplace screening with mobile mammography is one possible approach to the convenience barrier. However, fixed-facility workplace screening is a viable alternative for any company with a large workforce in one location. This paper describes our initial experience with one such fixed facility. The facility was a cooperative venture by a large pharmaceutical company and an academic radiology department to provide convenient, no-cost (to the patient) screening mammography to employees, dependents, and retirees more than 40 years old. The pharmaceutical company built the facility within its corporate headquarters and the academic radiology department provided the equipment and personnel. The company was billed a fixed cost per examination. In the first 22 months of operation, 4210 (of 4559 scheduled) screening mammograms were obtained. The mean age of the population was 53 years old. Ninety percent of the screening mammograms were interpreted as negative or benign; 10% required additional workup. Of the screened population, 62 biopsies were recommended and 60 were performed. Of these, 42 were benign and 18 malignant. The cancer detection rate was 4.3 per 1000 (0.43%). At the time of diagnosis, six patients were stage 0, 10 patients were stage I, one patient was stage II, and one patient was stage III. Eleven of the 18 patients had minimal cancers. Of the patients who completed a satisfaction survey, 97% percent expressed a high degree of satisfaction with the screening process and stated they would use the facility in the future. A fixed facility for workplace screening mammography is a viable way to provide nearly barrier-free access to high-quality mammography. Patient acceptance is high.

  3. Physiological effects and optimisation of nasal assist-control ventilation for patients with chronic obstructive pulmonary disease in respiratory failure

    PubMed Central

    Girault, C.; Chevron, V.; Richard, J. C.; Daudenthun, I.; Pasquis, P.; Leroy, J.; Bonmarchand, G.

    1997-01-01

    BACKGROUND: A study was undertaken to investigate the effects of non- invasive assist-control ventilation (ACV) by nasal mask on respiratory physiological parameters and comfort in acute on chronic respiratory failure (ACRF). METHODS: Fifteen patients with chronic obstructive pulmonary disease (COPD) were prospectively and randomly assigned to two non-invasive ventilation (NIV) sequences in spontaneous breathing (SB) and ACV mode. ACV settings were always optimised and therefore subsequently adjusted according to patient's tolerance and air leaks. RESULTS: ACV significantly decreased all the total inspiratory work of breathing (WOBinsp) parameters, pressure time product, and oesophageal pressure variation in comparison with SB mode. The ACV mode also resulted in a significant reduction in surface diaphragmatic electromyographic activity to 36% of the control values and significantly improved the breathing pattern. SB did not change the arterial blood gas tensions from baseline values whereas ACV significantly improved both the PaO2 from a mean (SD) of 8.45 (2.95) kPa to 13.31 (2.15) kPa, PaCO2 from 9.52 (1.61) kPa to 7.39 (1.39) kPa, and the pH from 7.32 (0.03) to 7.40 (0.07). The respiratory comfort was significantly lower with ACV than with SB. CONCLUSIONS: This study shows that the clinical benefit of non-invasive ACV in the management of ACRF in patients with COPD results in a reduced inspiratory muscle activity providing an improvement in breathing pattern and gas exchange. Despite respiratory discomfort, the muscle rest provided appears sufficient when ACV settings are optimised. 


 PMID:9337827

  4. A standard-driven approach for electronic submission to pharmaceutical regulatory authorities.

    PubMed

    Lin, Ching-Heng; Chou, Hsin-I; Yang, Ueng-Cheng

    2018-03-01

    Using standards is not only useful for data interchange during the process of a clinical trial, but also useful for analyzing data in a review process. Any step, which speeds up approval of new drugs, may benefit patients. As a result, adopting standards for regulatory submission becomes mandatory in some countries. However, preparing standard-compliant documents, such as annotated case report form (aCRF), needs a great deal of knowledge and experience. The process is complex and labor-intensive. Therefore, there is a need to use information technology to facilitate this process. Instead of standardizing data after the completion of a clinical trial, this study proposed a standard-driven approach. This approach was achieved by implementing a computer-assisted "standard-driven pipeline (SDP)" in an existing clinical data management system. SDP used CDISC standards to drive all processes of a clinical trial, such as the design, data acquisition, tabulation, etc. RESULTS: A completed phase I/II trial was used to prove the concept and to evaluate the effects of this approach. By using the CDISC-compliant question library, aCRFs were generated automatically when the eCRFs were completed. For comparison purpose, the data collection process was simulated and the collected data was transformed by the SDP. This new approach reduced the missing data fields from sixty-two to eight and the controlled term mismatch field reduced from eight to zero during data tabulation. This standard-driven approach accelerated CRF annotation and assured data tabulation integrity. The benefits of this approach include an improvement in the use of standards during the clinical trial and a reduction in missing and unexpected data during tabulation. The standard-driven approach is an advanced design idea that can be used for future clinical information system development. Copyright © 2018 Elsevier Inc. All rights reserved.

  5. 33 CFR 154.1225 - Specific response plan development and evaluation criteria and other requirements for fixed...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... transport animal fats or vegetable oils. 154.1225 Section 154.1225 Navigation and Navigable Waters COAST... MATERIAL IN BULK Response Plans for Animal Fats and Vegetable Oils Facilities § 154.1225 Specific response..., or transport animal fats or vegetable oils. (a) The owner or operator of a fixed facility that...

  6. 33 CFR 154.1225 - Specific response plan development and evaluation criteria and other requirements for fixed...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... transport animal fats or vegetable oils. 154.1225 Section 154.1225 Navigation and Navigable Waters COAST... MATERIAL IN BULK Response Plans for Animal Fats and Vegetable Oils Facilities § 154.1225 Specific response..., or transport animal fats or vegetable oils. (a) The owner or operator of a fixed facility that...

  7. 48 CFR 970.5215-3 - Conditional payment of fee, profit, and other incentives-facility management contracts

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... period, the DOE Operations/Field Office Manager, or designee, may reduce any otherwise earned fee, fixed... prescribed in 970.1504-5(b)(1), insert the following clause: Conditional Payment of Fee, Profit, and Other Incentives—Facility Management Contracts (AUG 2009) (a) General. (1) The payment of earned fee, fixed fee...

  8. 33 CFR 154.1225 - Specific response plan development and evaluation criteria and other requirements for fixed...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... transport animal fats or vegetable oils. 154.1225 Section 154.1225 Navigation and Navigable Waters COAST... MATERIAL IN BULK Response Plans for Animal Fats and Vegetable Oils Facilities § 154.1225 Specific response..., or transport animal fats or vegetable oils. (a) The owner or operator of a fixed facility that...

  9. 33 CFR 154.1225 - Specific response plan development and evaluation criteria and other requirements for fixed...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... transport animal fats or vegetable oils. 154.1225 Section 154.1225 Navigation and Navigable Waters COAST... MATERIAL IN BULK Response Plans for Animal Fats and Vegetable Oils Facilities § 154.1225 Specific response..., or transport animal fats or vegetable oils. (a) The owner or operator of a fixed facility that...

  10. 33 CFR 154.1225 - Specific response plan development and evaluation criteria and other requirements for fixed...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... transport animal fats or vegetable oils. 154.1225 Section 154.1225 Navigation and Navigable Waters COAST... MATERIAL IN BULK Response Plans for Animal Fats and Vegetable Oils Facilities § 154.1225 Specific response..., or transport animal fats or vegetable oils. (a) The owner or operator of a fixed facility that...

  11. 40 CFR 113.4 - Size classes and associated liability limits for fixed onshore oil storage facilities, 1,000...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 23 2012-07-01 2012-07-01 false Size classes and associated liability limits for fixed onshore oil storage facilities, 1,000 barrels or less capacity. 113.4 Section 113.4 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS LIABILITY LIMITS FOR...

  12. 40 CFR 113.4 - Size classes and associated liability limits for fixed onshore oil storage facilities, 1,000...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 22 2014-07-01 2013-07-01 true Size classes and associated liability limits for fixed onshore oil storage facilities, 1,000 barrels or less capacity. 113.4 Section 113.4 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS LIABILITY LIMITS FOR...

  13. Clinical Nursing Records Study

    DTIC Science & Technology

    1991-08-01

    In-depth assessment of current AMEDD nursing documentation system used in fixed facilities; 2 - 4) development, implementation and assessment of...used in fixed facilities to: a) identify system problems; b) identify potential solutions to problems; c) set priorities fc problem resolution; d...enhance compatibility between any " hard copy" forms the group might develop and automation requirements. Discussions were also held with personnel from

  14. Facility and Laboratory Equipment | Energy Systems Integration Facility |

    Science.gov Websites

    Energy Systems Integration Facility is its infrastructure. In addition to extensive fixed laboratory . Photo of researchers testing building loads and power networks in the Systems Performance Laboratory

  15. 49 CFR 611.105 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... public transportation and other high occupancy vehicles, or uses a fixed catenary system and a right of... rail, commuter rail, automated guideway transit, people movers, ferry boat service, and fixed-guideway facilities for buses (such as bus rapid transit) and other high occupancy vehicles. A new fixed guideway...

  16. 49 CFR 611.105 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... public transportation and other high occupancy vehicles, or uses a fixed catenary system and a right of... rail, commuter rail, automated guideway transit, people movers, ferry boat service, and fixed-guideway facilities for buses (such as bus rapid transit) and other high occupancy vehicles. A new fixed guideway...

  17. Mobile Versus Fixed Facility: Latinas' Attitudes and Preferences for Obtaining a Mammogram.

    PubMed

    Scheel, John R; Tillack, Allison A; Mercer, Lauren; Coronado, Gloria D; Beresford, Shirley A A; Molina, Yamile; Thompson, Beti

    2018-01-01

    Mobile mammographic services have been proposed as a way to reduce Latinas' disproportionate late-stage presentation compared with white women by increasing their access to mammography. The aims of this study were to assess why Latinas may not use mobile mammographic services and to explore their preferences after using these services. Using a mixed-methods approach, a secondary analysis was conducted of baseline survey data (n = 538) from a randomized controlled trial to improve screening mammography rates among Latinas in Washington. Descriptive statistics and bivariate regression were used to characterize mammography location preferences and to test for associations with sociodemographic indices, health care access, and perceived breast cancer risk and beliefs. On the basis of these findings, a qualitative study (n = 18) was used to explore changes in perceptions after using mobile mammographic services. More Latinas preferred obtaining a mammogram at a fixed facility (52.3% [n = 276]) compared with having no preference (46.3% [n = 249]) and preferring mobile mammographic services (1.7% [n = 9]). Concerns about privacy and comfort (15.6% [n = 84]) and about general quality (10.6% [n = 57]) were common reasons for preferring a fixed facility. Those with no history of mammography preferred a fixed facility (P < .05). In the qualitative study, Latinas expressed similar initial concerns but became positive toward the mobile mammographic services after obtaining a mammogram. Although most Latinas preferred obtaining a mammogram at a fixed facility, positive experiences with mobile mammography services changed their attitudes toward them. These findings highlight the need to include community education when using mobile mammographic service to increase screening mammography rates in underserved communities. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  18. The Mixed-Phase Arctic Cloud Experiment (M-PACE)

    NASA Technical Reports Server (NTRS)

    Verlinde, J.; Harrington, J. Y.; McFarquhar, G. M.; Yannuzzi, V. T.; Avramov, A.; Greenberg, S.; Johnson, N.; Zhang, G.; Poellot, M. R.; Mather, J. H.; hide

    2007-01-01

    The Mixed-Phase Arctic Cloud Experiment (M-PACE) was conducted September 27 through October 22, 2004 on the North Slope of Alaska. The primary objective was to collect a data set suitable to study interactions between microphysics, dynamics and radiative transfer in mixed-phase Arctic clouds. Observations taken during the 1997/1998 Surface Heat and Energy Budget of the Arctic (SHEBA) experiment revealed that Arctic clouds frequently consist of one (or more) liquid layers precipitating ice. M-PACE sought to investigate the physical processes of these clouds utilizing two aircraft (an in situ aircraft to characterize the microphysical properties of the clouds and a remote sensing aircraft to constraint the upwelling radiation) over the Department of Energy s Atmospheric Radiation Measurement (ARM) Climate Research Facility (ACRF) on the North Slope of Alaska. The measurements successfully documented the microphysical structure of Arctic mixed-phase clouds, with multiple in situ profiles collected in both single-layer and multi-layer clouds over two ground-based remote sensing sites. Liquid was found in clouds with temperatures down to -30 C, the coldest cloud top temperature below -40 C sampled by the aircraft. Remote sensing instruments suggest that ice was present in low concentrations, mostly concentrated in precipitation shafts, although there are indications of light ice precipitation present below the optically thick single-layer clouds. The prevalence of liquid down to these low temperatures could potentially be explained by the relatively low measured ice nuclei concentrations.

  19. 30 CFR 285.710 - When conducting onsite installation inspections, what must the CVA or project engineer do?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... SERVICE, DEPARTMENT OF THE INTERIOR OFFSHORE RENEWABLE ENERGY ALTERNATE USES OF EXISTING FACILITIES ON THE OUTER CONTINENTAL SHELF Facility Design, Fabrication, and Installation Certified Verification Agent... Facility Design Report and the Fabrication and Installation Report. (b) For a fixed or floating facility...

  20. Establishment of the Co-C Eutectic Fixed-Point Cell for Thermocouple Calibrations at NIMT

    NASA Astrophysics Data System (ADS)

    Ongrai, O.; Elliott, C. J.

    2017-08-01

    In 2015, NIMT first established a Co-C eutectic temperature reference (fixed-point) cell measurement capability for thermocouple calibration to support the requirements of Thailand's heavy industries and secondary laboratories. The Co-C eutectic fixed-point cell is a facility transferred from NPL, where the design was developed through European and UK national measurement system projects. In this paper, we describe the establishment of a Co-C eutectic fixed-point cell for thermocouple calibration at NIMT. This paper demonstrates achievement of the required furnace uniformity, the Co-C plateau realization and the comparison data between NIMT and NPL Co-C cells by using the same standard Pt/Pd thermocouple, demonstrating traceability. The NIMT measurement capability for noble metal type thermocouples at the new Co-C eutectic fixed point (1324.06°C) is estimated to be within ± 0.60 K (k=2). This meets the needs of Thailand's high-temperature thermocouple users—for which previously there has been no traceable calibration facility.

  1. 33 CFR 127.205 - Emergency shutdown.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) WATERFRONT FACILITIES WATERFRONT FACILITIES HANDLING LIQUEFIED NATURAL GAS AND LIQUEFIED HAZARDOUS GAS Waterfront Facilities Handling Liquefied Natural Gas Equipment § 127.205 Emergency shutdown. Each transfer... automatically when the fixed sensors under § 127.201(b) measure LNG concentrations exceeding 40% of the lower...

  2. 33 CFR 127.205 - Emergency shutdown.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) WATERFRONT FACILITIES WATERFRONT FACILITIES HANDLING LIQUEFIED NATURAL GAS AND LIQUEFIED HAZARDOUS GAS Waterfront Facilities Handling Liquefied Natural Gas Equipment § 127.205 Emergency shutdown. Each transfer... automatically when the fixed sensors under § 127.201(b) measure LNG concentrations exceeding 40% of the lower...

  3. Fixed site neutralization model programmer's manual. Volume II

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Engi, D.; Chapman, L.D.; Judnick, W.

    This report relates to protection of nuclear materials at nuclear facilities. This volume presents the source listings for the Fixed Site Neutralization Model and its supporting modules, the Plex Preprocessor and the Data Preprocessor. (DLC)

  4. Unequal-area, fixed-shape facility layout problems using the firefly algorithm

    NASA Astrophysics Data System (ADS)

    Ingole, Supriya; Singh, Dinesh

    2017-07-01

    In manufacturing industries, the facility layout design is a very important task, as it is concerned with the overall manufacturing cost and profit of the industry. The facility layout problem (FLP) is solved by arranging the departments or facilities of known dimensions on the available floor space. The objective of this article is to implement the firefly algorithm (FA) for solving unequal-area, fixed-shape FLPs and optimizing the costs of total material handling and transportation between the facilities. The FA is a nature-inspired algorithm and can be used for combinatorial optimization problems. Benchmark problems from the previous literature are solved using the FA. To check its effectiveness, it is implemented to solve large-sized FLPs. Computational results obtained using the FA show that the algorithm is less time consuming and the total layout costs for FLPs are better than the best results achieved so far.

  5. 33 CFR 127.201 - Sensing and alarm systems.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... vapor or gas may accumulate; and (2) Meet Section 9-4 of NFPA 59A. (c) Fixed sensors that continuously... (CONTINUED) WATERFRONT FACILITIES WATERFRONT FACILITIES HANDLING LIQUEFIED NATURAL GAS AND LIQUEFIED HAZARDOUS GAS Waterfront Facilities Handling Liquefied Natural Gas Equipment § 127.201 Sensing and alarm...

  6. 33 CFR 127.201 - Sensing and alarm systems.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... vapor or gas may accumulate; and (2) Meet Section 9-4 of NFPA 59A. (c) Fixed sensors that continuously... (CONTINUED) WATERFRONT FACILITIES WATERFRONT FACILITIES HANDLING LIQUEFIED NATURAL GAS AND LIQUEFIED HAZARDOUS GAS Waterfront Facilities Handling Liquefied Natural Gas Equipment § 127.201 Sensing and alarm...

  7. 33 CFR 154.1210 - Purpose and applicability.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (CONTINUED) POLLUTION FACILITIES TRANSFERRING OIL OR HAZARDOUS MATERIAL IN BULK Response Plans for Animal Fats and Vegetable Oils Facilities § 154.1210 Purpose and applicability. (a) The requirements of this... fats or vegetable oils including— (1) A fixed MTR facility capable of transferring oil in bulk, to or...

  8. 33 CFR 154.1210 - Purpose and applicability.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) POLLUTION FACILITIES TRANSFERRING OIL OR HAZARDOUS MATERIAL IN BULK Response Plans for Animal Fats and Vegetable Oils Facilities § 154.1210 Purpose and applicability. (a) The requirements of this... fats or vegetable oils including— (1) A fixed MTR facility capable of transferring oil in bulk, to or...

  9. 47 CFR 101.705 - Special showing for renewal of common carrier station facilities using frequency diversity.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Common Carrier Fixed Point-to-Point Microwave Service § 101.705 Special showing for renewal of common carrier station...

  10. 47 CFR 101.705 - Special showing for renewal of common carrier station facilities using frequency diversity.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Common Carrier Fixed Point-to-Point Microwave Service § 101.705 Special showing for renewal of common carrier station...

  11. 47 CFR 101.705 - Special showing for renewal of common carrier station facilities using frequency diversity.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Common Carrier Fixed Point-to-Point Microwave Service § 101.705 Special showing for renewal of common carrier station...

  12. 47 CFR 101.705 - Special showing for renewal of common carrier station facilities using frequency diversity.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Common Carrier Fixed Point-to-Point Microwave Service § 101.705 Special showing for renewal of common carrier station...

  13. Integrated Facilities Management and Fixed Asset Accounting.

    ERIC Educational Resources Information Center

    Golz, W. C., Jr.

    1984-01-01

    A record of a school district's assets--land, buildings, machinery, and equipment--can be a useful management tool that meets accounting requirements and provides appropriate information for budgeting, forecasting, and facilities management. (MLF)

  14. 33 CFR 154.1210 - Purpose and applicability.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Fats and Vegetable Oils Facilities § 154.1210 Purpose and applicability. (a) The requirements of this... fats or vegetable oils including— (1) A fixed MTR facility capable of transferring oil in bulk, to or...

  15. 33 CFR 154.1210 - Purpose and applicability.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Fats and Vegetable Oils Facilities § 154.1210 Purpose and applicability. (a) The requirements of this... fats or vegetable oils including— (1) A fixed MTR facility capable of transferring oil in bulk, to or...

  16. 33 CFR 154.1210 - Purpose and applicability.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Fats and Vegetable Oils Facilities § 154.1210 Purpose and applicability. (a) The requirements of this... fats or vegetable oils including— (1) A fixed MTR facility capable of transferring oil in bulk, to or...

  17. 48 CFR 1845.7101-3 - Unit acquisition cost.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... buildings and other facilities. (7) An appropriate share of the cost of the equipment and facilities used in construction work. (8) Fixed equipment and related installation costs required for activities in a building or... construction work. (10) Legal and recording fees and damage claims. (11) Fair values of facilities and...

  18. 48 CFR 1845.7101-3 - Unit acquisition cost.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... buildings and other facilities. (7) An appropriate share of the cost of the equipment and facilities used in construction work. (8) Fixed equipment and related installation costs required for activities in a building or... construction work. (10) Legal and recording fees and damage claims. (11) Fair values of facilities and...

  19. 48 CFR 1845.7101-3 - Unit acquisition cost.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... buildings and other facilities. (7) An appropriate share of the cost of the equipment and facilities used in construction work. (8) Fixed equipment and related installation costs required for activities in a building or... construction work. (10) Legal and recording fees and damage claims. (11) Fair values of facilities and...

  20. 48 CFR 1845.7101-3 - Unit acquisition cost.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... buildings and other facilities. (7) An appropriate share of the cost of the equipment and facilities used in construction work. (8) Fixed equipment and related installation costs required for activities in a building or... construction work. (10) Legal and recording fees and damage claims. (11) Fair values of facilities and...

  1. 47 CFR 101.135 - Shared use of radio stations and the offering of private carrier service.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Technical Standards § 101... Operational Fixed Point-to-Point Microwave radio stations may share the use of their facilities on a non...

  2. 47 CFR 101.135 - Shared use of radio stations and the offering of private carrier service.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Technical Standards § 101... Operational Fixed Point-to-Point Microwave radio stations may share the use of their facilities on a non...

  3. 47 CFR 101.135 - Shared use of radio stations and the offering of private carrier service.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Technical Standards § 101... Operational Fixed Point-to-Point Microwave radio stations may share the use of their facilities on a non...

  4. 47 CFR 101.135 - Shared use of radio stations and the offering of private carrier service.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Technical Standards § 101... Operational Fixed Point-to-Point Microwave radio stations may share the use of their facilities on a non...

  5. 47 CFR 101.135 - Shared use of radio stations and the offering of private carrier service.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Technical Standards § 101... Operational Fixed Point-to-Point Microwave radio stations may share the use of their facilities on a non...

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Berg, Larry K.; Riihimaki, Laura D.; Qian, Yun

    This study utilizes five commonly used reanalysis products, including the NCEP-DOE Reanalysis 2 (NCEP2), ECMWF Re-Analysis (ERA)-Interim, Japanese 25-year Reanalysis (JRA-25), Modern-Era Retrospective Analysis for Research and Applications (MERRA), and North American Regional Reanalysis (NARR) to evaluate features of the Southern Great Plains Low Level Jet (LLJ) above the Atmospheric Radiation Measurement (ARM) Climate Research Facility (ACRF) Southern Great Plains site. Two sets of radiosonde data are utilized: the six-week Midlatitude Continental Convective Clouds Experiment (MC3E), and a ten-year period spanning 2001-2010. All five reanalysis are compared to MC3E data, while only the NARR and MERRA are compared to themore » ten-year data. Each reanalysis is able to represent most aspects of the composite LLJ profile, although there is a tendency for each reanalysis to overestimate the wind speed between the nose of the LLJ and 700 mb. There are large discrepancies in the number of LLJ observed and derived from the reanalysis, particularly for strong LLJs that leads to an underestimate of the water vapor transport associated with LLJs. When the ten-year period is considered, the NARR overestimates and MERRA underestimates the total moisture transport, but both underestimate the transport associated with strong LLJs by factors of 2.0 and 2.7 for the NARR and MERR, respectively. During MC3E there were differences in the patterns of moisture convergence and divergence, with the MERRA having an area of moisture divergence over Oklahoma, while the NARR has moisture convergence. The patterns of moisture convergence and divergence are more consistent during the ten-year period.« less

  7. 48 CFR 970.5215-3 - Conditional payment of fee, profit, and other incentives-facility management contracts

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... period, the DOE Operations/Field Office Manager, or designee, may reduce any otherwise earned fee, fixed... Operations/Field Office Manager, or designee, may reduce in whole or in part any otherwise earned fee, fixed...

  8. 47 CFR 101.1 - Scope and authority.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE... applications for radio station licenses in the fixed microwave services. (b) The purpose of the rules in this..., microwave operations that require transmitting facilities on land or in specified offshore coastal areas...

  9. 47 CFR 101.1 - Scope and authority.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE... applications for radio station licenses in the fixed microwave services. (b) The purpose of the rules in this..., microwave operations that require transmitting facilities on land or in specified offshore coastal areas...

  10. 47 CFR 101.1 - Scope and authority.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE... applications for radio station licenses in the fixed microwave services. (b) The purpose of the rules in this..., microwave operations that require transmitting facilities on land or in specified offshore coastal areas...

  11. 47 CFR 101.1 - Scope and authority.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE... applications for radio station licenses in the fixed microwave services. (b) The purpose of the rules in this..., microwave operations that require transmitting facilities on land or in specified offshore coastal areas...

  12. 47 CFR 101.1 - Scope and authority.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE... applications for radio station licenses in the fixed microwave services. (b) The purpose of the rules in this..., microwave operations that require transmitting facilities on land or in specified offshore coastal areas...

  13. 30 CFR 285.825 - When must I assess my facilities?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Section 285.825 Mineral Resources BUREAU OF OCEAN ENERGY MANAGEMENT, REGULATION, AND ENFORCEMENT... CONTINENTAL SHELF Environmental and Safety Management, Inspections, and Facility Assessments for Activities... and Constructing Fixed Offshore Platforms—Working Stress Design (incorporated by reference, as...

  14. Development of an Implantable Fish Spawning Sensor Tag

    DTIC Science & Technology

    2013-09-24

    Manatee Hatchery Facility, Port Manatee , Florida) using a Millar Instruments pressure catheter inserted a fixed distance (15cm) into the ovary before and...red drum aquaculture facility in Port Manatee , Florida (or similar aquaculture facility where spawning fishes are kept). This facility maintains a...at the Port Manatee hatchery and phase three tests on goliath grouper in the field. RESULTS *Please refer to other sections for more details and

  15. 30 CFR 285.710 - When conducting onsite installation inspections, what must the CVA or project engineer do?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... ALTERNATE USES OF EXISTING FACILITIES ON THE OUTER CONTINENTAL SHELF Facility Design, Fabrication, and..., survey, or check, the installation items required by this section. (a) The CVA or project engineer must... according to the Facility Design Report and the Fabrication and Installation Report. (b) For a fixed or...

  16. 33 CFR 127.1203 - Gas detection.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... waterfront facility handling LHG that transfers a flammable LHG must have at least two portable gas detectors, or a fixed gas detector, in the marine transfer area for LHG. Each detector must be capable of... detectors, or a fixed gas detector, available in the area. The detectors must be capable of showing whether...

  17. 33 CFR 127.1203 - Gas detection.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... waterfront facility handling LHG that transfers a flammable LHG must have at least two portable gas detectors, or a fixed gas detector, in the marine transfer area for LHG. Each detector must be capable of... detectors, or a fixed gas detector, available in the area. The detectors must be capable of showing whether...

  18. 33 CFR 127.1203 - Gas detection.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... waterfront facility handling LHG that transfers a flammable LHG must have at least two portable gas detectors, or a fixed gas detector, in the marine transfer area for LHG. Each detector must be capable of... detectors, or a fixed gas detector, available in the area. The detectors must be capable of showing whether...

  19. 33 CFR 127.1203 - Gas detection.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... waterfront facility handling LHG that transfers a flammable LHG must have at least two portable gas detectors, or a fixed gas detector, in the marine transfer area for LHG. Each detector must be capable of... detectors, or a fixed gas detector, available in the area. The detectors must be capable of showing whether...

  20. 33 CFR 127.1203 - Gas detection.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... waterfront facility handling LHG that transfers a flammable LHG must have at least two portable gas detectors, or a fixed gas detector, in the marine transfer area for LHG. Each detector must be capable of... detectors, or a fixed gas detector, available in the area. The detectors must be capable of showing whether...

  1. Atmospheric Radiation Measurement Program Climate Research Facility Operation quarterly report July 1 - September 30, 2010.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sisterson, D. L.

    2010-10-26

    Individual raw datastreams from instrumentation at the Atmospheric Radiation Measurement (ARM) Climate Research Facility fixed and mobile sites are collected and sent to the Data Management Facility (DMF) at Pacific Northwest National Laboratory (PNNL) for processing in near real-time. Raw and processed data are then sent approximately daily to the ARM Archive, where they are made available to users. For each instrument, we calculate the ratio of the actual number of data records received daily at the Archive to the expected number of data records. The results are tabulated by (1) individual datastream, site, and month for the current yearmore » and (2) site and fiscal year (FY) dating back to 1998. The U.S. Department of Energy (DOE) requires national user facilities to report time-based operating data. The requirements concern the actual hours of operation (ACTUAL); the estimated maximum operation or uptime goal (OPSMAX), which accounts for planned downtime; and the VARIANCE [1-(ACTUAL/OPSMAX)], which accounts for unplanned downtime. The OPSMAX time for the fourth quarter of FY2010 for the Southern Great Plains (SGP) site is 2097.60 hours (0.95 2208 hours this quarter). The OPSMAX for the North Slope of Alaska (NSA) locale is 1987.20 hours (0.90 2208) and for the Tropical Western Pacific (TWP) locale is 1876.80 hours (0.85 2208). The first ARM Mobile Facility (AMF1) deployment in Graciosa Island, the Azores, Portugal, continues, so the OPSMAX time this quarter is 2097.60 hours (0.95 x 2208). The differences in OPSMAX performance reflect the complexity of local logistics and the frequency of extreme weather events. It is impractical to measure OPSMAX for each instrument or datastream. Data availability reported here refers to the average of the individual, continuous datastreams that have been received by the Archive. Data not at the Archive are caused by downtime (scheduled or unplanned) of the individual instruments. Therefore, data availability is directly related to individual instrument uptime. Thus, the average percentage of data in the Archive represents the average percentage of the time (24 hours per day, 92 days for this quarter) that the instruments were operating this quarter. Table 1 shows the accumulated maximum operation time (planned uptime), actual hours of operation, and variance (unplanned downtime) for the period July 1-September 30, 2010, for the fixed sites. Because the AMF operates episodically, the AMF statistics are reported separately and not included in the aggregate average with the fixed sites. This fourth quarter comprises a total of 2208 possible hours for the fixed and mobile sites. The average of the fixed sites exceeded our goal this quarter. The Site Access Request System is a web-based database used to track visitors to the fixed and mobile sites, all of which have facilities that can be visited. The NSA locale has the Barrow and Atqasuk sites. The SGP site has historically had a Central Facility, 23 extended facilities, 4 boundary facilities, and 3 intermediate facilities. Beginning in the second quarter of FY2010, the SGP began a transition to a smaller footprint (150 km x 150 km) by rearranging the original instrumentation and new instrumentation made available through the American Recovery and Reinvestment Act of 2009 (ARRA). The Central Facility and 4 extended facilities will remain, but there will be up to 12 new surface characterization facilities, 4 radar facilities, and 3 profiler facilities sited in the smaller domain. This new configuration will provide observations at scales more appropriate to current and future climate models. The transition to the smaller footprint is ongoing through this quarter. The TWP locale has the Manus, Nauru, and Darwin sites. These sites will also have expanded measurement capabilities with the addition of new instrumentation made available through ARRA funds. It is anticipated that the new instrumentation at all the fixed sites will be in place by the end of calendar year 2011. AMF1 continues its 20-month deployment in Graciosa Island, the Azores, Portugal, that began on May 1, 2009. The AMF will also have additional observational capabilities by the end of 2011. The second ARM Mobile Facility (AMF2) was deployed this quarter to Steamboat Springs, Colorado, in support of the Storm Peak Lab Cloud Property Validation Experiment (STORMVEX). The first field deployment of the second ARM Mobile Facility will be used to validate ARM-developed algorithms that convert the remote sensing measurements to cloud properties for liquid and mixed phase clouds. Although AMF2 is being set up this quarter, the official start date of the field campaign is not until November 1, 2010. This quarterly report provides the cumulative numbers of scientific user accounts by site for the period October 1, 2009-September 30, 2010.« less

  2. 42 CFR 413.237 - Outliers.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...-only drugs effective January 1, 2014. (2) Adult predicted ESRD outlier services Medicare allowable... furnished to an adult beneficiary by an ESRD facility. (3) Pediatric predicted ESRD outlier services... outlier services furnished to a pediatric beneficiary by an ESRD facility. (4) Adult fixed dollar loss...

  3. Fixed Base Modal Testing Using the NASA GRC Mechanical Vibration Facility

    NASA Technical Reports Server (NTRS)

    Staab, Lucas D.; Winkel, James P.; Suarez, Vicente J.; Jones, Trevor M.; Napolitano, Kevin L.

    2016-01-01

    The Space Power Facility at NASA's Plum Brook Station houses the world's largest and most powerful space environment simulation facilities, including the Mechanical Vibration Facility (MVF), which offers the world's highest-capacity multi-axis spacecraft shaker system. The MVF was designed to perform sine vibration testing of a Crew Exploration Vehicle (CEV)-class spacecraft with a total mass of 75,000 pounds, center of gravity (cg) height above the table of 284 inches, diameter of 18 feet, and capability of 1.25 gravity units peak acceleration in the vertical and 1.0 gravity units peak acceleration in the lateral directions. The MVF is a six-degree-of-freedom, servo-hydraulic, sinusoidal base-shake vibration system that has the advantage of being able to perform single-axis sine vibration testing of large structures in the vertical and two lateral axes without the need to reconfigure the test article for each axis. This paper discusses efforts to extend the MVF's capabilities so that it can also be used to determine fixed base modes of its test article without the need for an expensive test-correlated facility simulation.

  4. Improving Mixed-phase Cloud Parameterization in Climate Model with the ACRF Measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Zhien

    Mixed-phase cloud microphysical and dynamical processes are still poorly understood, and their representation in GCMs is a major source of uncertainties in overall cloud feedback in GCMs. Thus improving mixed-phase cloud parameterizations in climate models is critical to reducing the climate forecast uncertainties. This study aims at providing improved knowledge of mixed-phase cloud properties from the long-term ACRF observations and improving mixed-phase clouds simulations in the NCAR Community Atmosphere Model version 5 (CAM5). The key accomplishments are: 1) An improved retrieval algorithm was developed to provide liquid droplet concentration for drizzling or mixed-phase stratiform clouds. 2) A new ice concentrationmore » retrieval algorithm for stratiform mixed-phase clouds was developed. 3) A strong seasonal aerosol impact on ice generation in Arctic mixed-phase clouds was identified, which is mainly attributed to the high dust occurrence during the spring season. 4) A suite of multi-senor algorithms was applied to long-term ARM observations at the Barrow site to provide a complete dataset (LWC and effective radius profile for liquid phase, and IWC, Dge profiles and ice concentration for ice phase) to characterize Arctic stratiform mixed-phase clouds. This multi-year stratiform mixed-phase cloud dataset provides necessary information to study related processes, evaluate model stratiform mixed-phase cloud simulations, and improve model stratiform mixed-phase cloud parameterization. 5). A new in situ data analysis method was developed to quantify liquid mass partition in convective mixed-phase clouds. For the first time, we reliably compared liquid mass partitions in stratiform and convective mixed-phase clouds. Due to the different dynamics in stratiform and convective mixed-phase clouds, the temperature dependencies of liquid mass partitions are significantly different due to much higher ice concentrations in convective mixed phase clouds. 6) Systematic evaluations of mixed-phase cloud simulations by CAM5 were performed. Measurement results indicate that ice concentrations control stratiform mixed-phase cloud properties. The improvement of ice concentration parameterization in the CAM5 was done in close collaboration with Dr. Xiaohong Liu, PNNL (now at University of Wyoming).« less

  5. Maryland Health and Higher Educational Facilities Authority. 1996 Annual Report.

    ERIC Educational Resources Information Center

    Maryland State Health and Higher Educational Facilities Authority, Baltimore.

    The Maryland Health and Higher Educational Facilities Authority performs various functions including: issuing bonds and bond anticipation notes; fixing rates and collecting user rents and fees; constructing, acquiring, and maintaining institutional projects; contracting for operation and maintenance of projects; establishing rules and regulations…

  6. Design of a Facility to Test the Advanced Stirling Radioisotope Generator Engineering Unit

    NASA Technical Reports Server (NTRS)

    Lewandowski, Edward J.; Schreiber, Jeffrey G.; Oriti, Salvatore M.; Meer, David W.; Brace, Michael H.; Dugala, Gina

    2009-01-01

    The Advanced Stirling Radioisotope Generator (ASRG) is being considered to power deep space missions. An engineering unit, the ASRG-EU, was designed and fabricated by Lockheed Martin under contract to the Department of Energy. This unit is currently on an extended operation test at NASA Glenn Research Center to generate performance data and validate the life and reliability predictions for the generator and the Stirling convertors. A special test facility was designed and built for testing the ASRG-EU. Details of the test facility design are discussed. The facility can operate the convertors under AC bus control or with the ASRG-EU controller. It can regulate input thermal power in either a fixed temperature or fixed power mode. An enclosure circulates cooled air around the ASRG-EU to remove heat rejected from the ASRG-EU by convection. A custom monitoring and data acquisition system supports the test. Various safety features, which allow 2417 unattended operation, are discussed.

  7. 47 CFR 101.705 - Special showing for renewal of common carrier station facilities using frequency diversity.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Special showing for renewal of common carrier... COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Common Carrier Fixed Point-to-Point Microwave Service § 101.705 Special showing for renewal of common carrier station...

  8. An Analysis of Methods for Maximizing the Utilization of Space in USAF Facilities.

    DTIC Science & Technology

    1987-09-01

    vegetable . peeling machines and dish washing machines- i. Fixed barracks equipment including sinks, troughs and washing machines of all types: .4. Fixed...Prentice-Hall, 1977. 52. Spillars, W.R. and S. Al- Banna . "An Interactive Computer Graphics Space Allocation System," DAW Nine. 229-237. Association for

  9. 10 CFR 50.51 - Continuation of license.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... NUCLEAR REGULATORY COMMISSION DOMESTIC LICENSING OF PRODUCTION AND UTILIZATION FACILITIES Issuance... license will be issued for a fixed period of time to be specified in the license but in no case to exceed... expiration date to authorize ownership and possession of the production or utilization facility, until the...

  10. 10 CFR 50.51 - Continuation of license.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... NUCLEAR REGULATORY COMMISSION DOMESTIC LICENSING OF PRODUCTION AND UTILIZATION FACILITIES Issuance... license will be issued for a fixed period of time to be specified in the license but in no case to exceed... expiration date to authorize ownership and possession of the production or utilization facility, until the...

  11. 47 CFR 101.55 - Considerations involving transfer or assignment applications.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    .... (d) If a proposed transfer of radio facilities is incidental to a sale or other facilities or merger... SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Applications and Licenses License Transfers, Modifications, Conditions and Forfeitures § 101.55 Considerations involving transfer or assignment applications. (a) Except...

  12. 47 CFR 101.55 - Considerations involving transfer or assignment applications.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    .... (d) If a proposed transfer of radio facilities is incidental to a sale or other facilities or merger... SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Applications and Licenses License Transfers, Modifications, Conditions and Forfeitures § 101.55 Considerations involving transfer or assignment applications. (a) Except...

  13. 47 CFR 101.55 - Considerations involving transfer or assignment applications.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    .... (d) If a proposed transfer of radio facilities is incidental to a sale or other facilities or merger... SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Applications and Licenses License Transfers, Modifications, Conditions and Forfeitures § 101.55 Considerations involving transfer or assignment applications. (a) Except...

  14. 47 CFR 101.55 - Considerations involving transfer or assignment applications.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    .... (d) If a proposed transfer of radio facilities is incidental to a sale or other facilities or merger... SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Applications and Licenses License Transfers, Modifications, Conditions and Forfeitures § 101.55 Considerations involving transfer or assignment applications. (a) Except...

  15. 47 CFR 101.55 - Considerations involving transfer or assignment applications.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    .... (d) If a proposed transfer of radio facilities is incidental to a sale or other facilities or merger... SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Applications and Licenses License Transfers, Modifications, Conditions and Forfeitures § 101.55 Considerations involving transfer or assignment applications. (a) Except...

  16. 78 FR 57250 - Federal Credit Union Ownership of Fixed Assets

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-18

    ..., branch office, suboffice, service center, parking lot, facility, real estate where an FCU transacts or... waiver request and suggested that the automatic approval provision in the current rule should be... office, suboffice, service center, parking lot, other facility, or real estate where the federal credit...

  17. STS-26 crew on fixed based (FB) shuttle mission simulator (SMS) flight deck

    NASA Technical Reports Server (NTRS)

    1988-01-01

    STS-26 Discovery, Orbiter Vehicle (OV) 103, Commander Frederick H. Hauck (left) and Pilot Richard O. Covey review checklists in their respective stations on the foward flight deck. The STS-26 crew is training in the fixed base (FB) shuttle mission simulator (SMS) located in JSC Mission Simulation and Training Facility Bldg 5.

  18. 7 CFR 4284.924 - Ineligible uses of grant and matching funds.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... or facility (including a processing facility); (d) Purchase, lease purchase, or install fixed equipment, including processing equipment; (e) Purchase or repair vehicles, including boats; (f) Pay for the... processing and marketing of the value-added product; (h) Fund research and development; (i) Fund political or...

  19. 7 CFR 4284.924 - Ineligible uses of grant and matching funds.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... or facility (including a processing facility); (d) Purchase, lease purchase, or install fixed equipment, including processing equipment; (e) Purchase or repair vehicles, including boats; (f) Pay for the... processing and marketing of the value-added product; (h) Fund research and development; (i) Fund political or...

  20. 7 CFR 4284.924 - Ineligible uses of grant and matching funds.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... or facility (including a processing facility); (d) Purchase, lease purchase, or install fixed equipment, including processing equipment; (e) Purchase or repair vehicles, including boats; (f) Pay for the... processing and marketing of the value-added product; (h) Fund research and development; (i) Fund political or...

  1. 40 CFR 125.136 - As an owner or operator of a new offshore oil and gas extraction facility, what must I collect...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... you are a fixed facility and your cooling water intake structure is located in an estuary or tidal... waterbody flow information. If your cooling water intake structure is located in an estuary or tidal river...

  2. 40 CFR 125.136 - As an owner or operator of a new offshore oil and gas extraction facility, what must I collect...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... you are a fixed facility and your cooling water intake structure is located in an estuary or tidal... waterbody flow information. If your cooling water intake structure is located in an estuary or tidal river...

  3. 40 CFR 125.136 - As an owner or operator of a new offshore oil and gas extraction facility, what must I collect...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... you are a fixed facility and your cooling water intake structure is located in an estuary or tidal... waterbody flow information. If your cooling water intake structure is located in an estuary or tidal river...

  4. Gasification Product Improvement Facility (GPIF). Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1995-09-01

    The gasifier selected for development under this contract is an innovative and patented hybrid technology which combines the best features of both fixed-bed and fluidized-bed types. PyGas{trademark}, meaning Pyrolysis Gasification, is well suited for integration into advanced power cycles such as IGCC. It is also well matched to hot gas clean-up technologies currently in development. Unlike other gasification technologies, PyGas can be designed into both large and small scale systems. It is expected that partial repowering with PyGas could be done at a cost of electricity of only 2.78 cents/kWh, more economical than natural gas repowering. It is extremely unfortunatemore » that Government funding for such a noble cause is becoming reduced to the point where current contracts must be canceled. The Gasification Product Improvement Facility (GPIF) project was initiated to provide a test facility to support early commercialization of advanced fixed-bed coal gasification technology at a cost approaching $1,000 per kilowatt for electric power generation applications. The project was to include an innovative, advanced, air-blown, pressurized, fixed-bed, dry-bottom gasifier and a follow-on hot metal oxide gas desulfurization sub-system. To help defray the cost of testing materials, the facility was to be located at a nearby utility coal fired generating site. The patented PyGas{trademark} technology was selected via a competitive bidding process as the candidate which best fit overall DOE objectives. The paper describes the accomplishments to date.« less

  5. STS-26 MS Lounge in fixed based (FB) shuttle mission simulator (SMS)

    NASA Technical Reports Server (NTRS)

    1988-01-01

    STS-26 Discovery, Orbiter Vehicle (OV) 103, Mission Specialist (MS) John M. Lounge, wearing comunications kit assembly headset and crouched on the aft flight deck, performs checklist inspection during training session. The STS-26 crew is training in the fixed base (FB) shuttle mission simulator (SMS) located in JSC Mission Simulation and Training Facility Bldg 5.

  6. STS-26 MS Hilmers on fixed based (FB) shuttle mission simulator (SMS) middeck

    NASA Technical Reports Server (NTRS)

    1988-01-01

    STS-26 Discovery, Orbiter Vehicle (OV) 103, Mission Specialist (MS) David C. Hilmers prepares to ascend a ladder representing the interdeck access hatch from the shuttle middeck to the flight deck. The STS-26 crew is training in the fixed base (FB) shuttle mission simulator (SMS) located in JSC Mission Simulation and Training Facility Bldg 5.

  7. “Lidar Investigations of Aerosol, Cloud, and Boundary Layer Properties Over the ARM ACRF Sites”

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ferrare, Richard; Turner, David

    2015-01-13

    Project goals; Characterize the aerosol and ice vertical distributions over the ARM NSA site, and in particular to discriminate between elevated aerosol layers and ice clouds in optically thin scattering layers; Characterize the water vapor and aerosol vertical distributions over the ARM Darwin site, how these distributions vary seasonally, and quantify the amount of water vapor and aerosol that is above the boundary layer; Use the high temporal resolution Raman lidar data to examine how aerosol properties vary near clouds; Use the high temporal resolution Raman lidar and Atmospheric Emitted Radiance Interferometer (AERI) data to quantify entrainment in optically thinmore » continental cumulus clouds; and Use the high temporal Raman lidar data to continue to characterize the turbulence within the convective boundary layer and how the turbulence statistics (e.g., variance, skewness) is correlated with larger scale variables predicted by models.« less

  8. Terahertz conductivity of twisted bilayer graphene

    NASA Astrophysics Data System (ADS)

    Chia, Elbert E. M.; Zou, Xingquan; Shang, Jingzhi; Leaw, Jianing; Luo, Zhiqiang; Luo, Liyan; Cheong, Siew Ann; Su, Haibin; Zhu, Jian-Xin; Castro Neto, A. H.; Yu, Ting

    2013-03-01

    Using terahertz time-domain spectroscopy, the real part of optical conductivity [σ1 (ω) ] of twisted bilayer graphene was obtained at different temperatures (10 - 300 K) in the frequency range 0.3 - 3 THz. On top of a Drude-like response, we see a strong and narrow peak in σ1 (ω) at ~2.7 THz. We analyze the overall Drude-like response using a disorder-dependent (unitary scattering) model, then attribute the peak at 2.7 THz to an enhanced density of states at that energy, that is caused by the presence of van Hove singularities arising from a commensurate twisting of the two graphene layers. Singapore MOE AcRF Tier 2 (ARC 23/08), NRF-CRP (NRF-CRP4-2008-04), NNSA of the U.S. DOE at LANL (DE-AC52-06NA25396), LANL LDRD Program, NRF-CRP (R-144-000-295-281), DOE DE-FG02-08ER46512, ONR MURI N00014-09-1-1063.

  9. Preliminary technical data summary No. 3 for the Defense Waste Processing Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Landon, L.F.

    1980-05-01

    This document presents an update on the best information presently available for the purpose of establishing the basis for the design of a Defense Waste Processing Facility. Objective of this project is to provide a facility to fix the radionuclides present in Savannah River Plant (SRP) high-level liquid waste in a high-integrity form (glass). Flowsheets and material balances reflect the alternate CAB case including the incorporation of low-level supernate in concrete. (DLC)

  10. Fourth-generation plasma immersion ion implantation and deposition facility for hybrid surface modification layer fabrication.

    PubMed

    Wang, Langping; Huang, Lei; Xie, Zhiwen; Wang, Xiaofeng; Tang, Baoyin

    2008-02-01

    The fourth-generation plasma immersion ion implantation and deposition (PIIID) facility for hybrid and batch treatment was built in our laboratory recently. Comparing with our previous PIIID facilities, several novel designs are utilized. Two multicathode pulsed cathodic arc plasma sources are fixed on the chamber wall symmetrically, which can increase the steady working time from 6 h (the single cathode source in our previous facilities) to about 18 h. Meanwhile, the inner diameter of the pulsed cathodic arc plasma source is increased from the previous 80 to 209 mm, thus, large area metal plasma can be obtained by the source. Instead of the simple sample holder in our previous facility, a complex revolution-rotation sample holder composed of 24 shafts, which can rotate around its axis and adjust its position through revolving around the center axis of the vacuum chamber, is fixed in the center of the vacuum chamber. In addition, one magnetron sputtering source is set on the chamber wall instead of the top cover in the previous facility. Because of the above characteristic, the PIIID hybrid process involving ion implantation, vacuum arc, and magnetron sputtering deposition can be acquired without breaking vacuum. In addition, the PIIID batch treatment of cylinderlike components can be finished by installing these components on the rotating shafts on the sample holder.

  11. Total cost comparison of 2 biopsy methods for nonpalpable breast lesions.

    PubMed

    Bodai, B I; Boyd, B; Brown, L; Wadley, H; Zannis, V J; Holzman, M

    2001-05-01

    To identify, quantify, and compare total facility costs for 2 breast biopsy methods: vacuum-assisted biopsy (VAB) and needle-wire-localized open surgical biopsy (OSB). A time-and-motion study was done to identify unit resources used in both procedures. Costs were imputed from published literature to value resources. A comparison of the total (fixed and variable) costs of the 2 procedures was done. A convenience sample of 2 high-volume breast biopsy (both VAB and OSB) facilities was identified. A third facility (OSB only) and 8 other sites (VAB only) were used to capture variation. Staff interviews, patient medical records, and billing data were used to check observed data. One hundred and sixty-seven uncomplicated procedures (71 OSBs, 96 VABs) were observed. Available demographic and clinical data were analyzed to assess selection bias, and sensitivity analyses were done on the main assumptions. The total facility costs of the VAB procedure were lower than the costs of the OSB procedure. The overall cost advantage for using VAB ranges from $314 to $843 per procedure depending on the facility type. Variable cost comparison indicated little difference between the 2 procedures. The largest fixed cost difference was $763. Facilities must consider the cost of new technology, especially when the new technology is as effective as the present technology. The seemingly high cost of equipment might negatively influence a decision to adopt VAB, but when total facility costs were analyzed, the new technology was less costly.

  12. Oblique view of Facility No. S362 showing the profile of ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Oblique view of Facility No. S362 showing the profile of the ramp. Note the mooring cleat fixed to the top edge of the curb at left - U.S. Naval Base, Pearl Harbor, Seaplane Ramps - World War II Type, Southwest and west shore of Ford Island, near Wasp Boulevard, Pearl City, Honolulu County, HI

  13. Better Contract Oversight Could Have Prevented Deficiencies in the Detention Facility in Parwan, Afghanistan

    DTIC Science & Technology

    2012-05-17

    a visitation center, a water treatment plant, and vocational buildings where detainees can learn carpentry and culinary skills. The facility also...room not connected MHU PPI 69 DCID HVAC unit is inoperable Ml DAB PPI has o rdered p arts and w ill fix w hen it arrives 70 Access broken to VCD

  14. ERLN Activities Details

    EPA Pesticide Factsheets

    Environmental Response Laboratory Network activities include the All Hazard Receipt Facility and Screening Protocol, standardizing chemical methods, Chemical Warfare Agent Fixed Laboratory Pilot Project, microbial efforts, and WLA response plan.

  15. Aerodynamic braking of high speed ground transportation vehicles.

    NASA Technical Reports Server (NTRS)

    Marte, J. E.; Marko, W. J.

    1973-01-01

    The drag effectiveness of aerodynamic brakes arranged in series on a train-like vehicle was investigated. Fixed- and moving-model testing techniques were used in order to determine the importance of proper vehicle-ground interference simulation. Fixed-model tests were carried out on a sting-mounted model: alone; with a fixed ground plane; and in proximity to an image model. Moving-model tests were conducted in a vertical slide-wire facility with and without a ground plane. Results from investigations of one brake configuration are presented which show the effect of the number of brakes in the set and of spacing between brakes.

  16. Gantry for medical particle therapy facility

    DOEpatents

    Trbojevic, Dejan [Wading River, NY

    2012-05-08

    A particle therapy gantry for delivering a particle beam to a patient includes a beam tube having a curvature defining a particle beam path and a plurality of fixed field magnets sequentially arranged along the beam tube for guiding the particle beam along the particle path. In a method for delivering a particle beam to a patient through a gantry, a particle beam is guided by a plurality of fixed field magnets sequentially arranged along a beam tube of the gantry and the beam is alternately focused and defocused with alternately arranged focusing and defocusing fixed field magnets.

  17. Characterizing Organic Aerosol Processes and Climatically Relevant Properties via Advanced and Integrated Analyses of Aerosol Mass Spectrometry Datasets from DOE Campaigns and ACRF Measurements. Final report for DE-SC0007178

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Qi

    Organic aerosols (OA) are an important but poorly characterized component of the earth’s climate system. Enormous complexities commonly associated with OA composition and life cycle processes have significantly complicated the simulation and quantification of aerosol effects. To unravel these complexities and improve understanding of the properties, sources, formation, evolution processes, and radiative properties of atmospheric OA, we propose to perform advanced and integrated analyses of multiple DOE aerosol mass spectrometry datasets, including two high-resolution time-of-flight aerosol mass spectrometer (HR-AMS) datasets from intensive field campaigns on the aerosol life cycle and the Aerosol Chemical Speciation Monitor (ACSM) datasets from long-term routinemore » measurement programs at ACRF sites. In this project, we will focus on 1) characterizing the chemical (i.e., composition, organic elemental ratios), physical (i.e., size distribution and volatility), and radiative (i.e., sub- and super-saturated growth) properties of organic aerosols, 2) examining the correlations of these properties with different source and process regimes (e.g., primary, secondary, urban, biogenic, biomass burning, marine, or mixtures), 3) quantifying the evolutions of these properties as a function of photochemical processing, 4) identifying and characterizing special cases for important processes such as SOA formation and new particle formation and growth, and 5) correlating size-resolved aerosol chemistry with measurements of radiative properties of aerosols to determine the climatically relevant properties of OA and characterize the relationship between these properties and processes of atmospheric aerosol organics. Our primary goal is to improve a process-level understanding of the life cycle of organic aerosols in the Earth’s atmosphere. We will also aim at bridging between observations and models via synthesizing and translating the results and insights generated from this research into data products and formulations that may be directly used to inform, improve, and evaluate regional and global models. In addition, we will continue our current very active collaborations with several modeling groups to enhance the use and interpretation of our data products. Overall, this research will contribute new data to improve quantification of the aerosol’s effects on climate and thus the achievement of ASR’s science goal of – “improving the fidelity and predictive capability of global climate models”.« less

  18. A Game Theoretical Model for Location of Terror Response Facilities under Capacitated Resources

    PubMed Central

    Kang, Qi; Xu, Weisheng; Wu, Qidi

    2013-01-01

    This paper is concerned with the effect of capacity constraints on the locations of terror response facilities. We assume that the state has limited resources, and multiple facilities may be involved in the response until the demand is satisfied consequently. We formulate a leader-follower game model between the state and the terrorist and prove the existence and uniqueness of the Nash equilibrium. An integer linear programming is proposed to obtain the equilibrium results when the facility number is fixed. The problem is demonstrated by a case study of the 19 districts of Shanghai, China. PMID:24459446

  19. Medical Services: Medical, Dental, and Veterinary Care

    DTIC Science & Technology

    2002-01-28

    requirements to fixed military treatment facility laboratories in Europe and Korea. Clarifies Joint Commission on the Accreditation of Healthcare ...which meets the requirements of the licensing and accrediting agencies (for example, FDA, AABB, Joint Commission on the Accreditation of Healthcare ...as officer in charge or equivalent status when no pharmacist is on duty at the facility. (2) Policies are established to ensure— (a) Rational

  20. Military Medical Care: Questions and Answers

    DTIC Science & Technology

    2013-07-24

    services through either Department of Defense (DOD) medical facilities, known as “military treatment facilities” or “MTFs” as space is available, or...Chiefs of Staff, CAE /PEO =Component Acquisition Executive/Program Executive Officer, DHA OGC = Defense Health Agency Office of General Counsel, NCR...funding for all fixed medical treatment facilities/activities, including such costs as real property maintenance, environmental compliance, minor

  1. Accidental hazardous material releases with human impacts in the United States: exploration of geographical distribution and temporal trends.

    PubMed

    Sengul, Hatice; Santella, Nicholas; Steinberg, Laura J; Chermak, Christina

    2010-09-01

    To investigate the circumstances and geographic and temporal distributions of hazardous material releases and resulting human impacts in the United States. Releases with fatalities, injuries, and evacuations were identified from reports to the National Response Center between 1990 and 2008, correcting for data quality issues identified in previous studies. From more than 550,000 reports, 861 deaths, 16,348 injuries and 741,427 evacuations were identified. Injuries from releases of chemicals at fixed facilities and natural gas from pipelines have decreased whereas evacuations from petroleum releases at fixed facilities have increased. Results confirm recent advances in chemical and pipeline safety and suggest directions for further improvement including targeted training and inspections and adoption of inherently safer design principles.

  2. Fixed Base Modal Survey of the MPCV Orion European Service Module Structural Test Article

    NASA Technical Reports Server (NTRS)

    Winkel, James P.; Akers, J. C.; Suarez, Vicente J.; Staab, Lucas D.; Napolitano, Kevin L.

    2017-01-01

    Recently, the MPCV Orion European Service Module Structural Test Article (E-STA) underwent sine vibration testing using the multi-axis shaker system at NASA GRC Plum Brook Station Mechanical Vibration Facility (MVF). An innovative approach using measured constraint shapes at the interface of E-STA to the MVF allowed high-quality fixed base modal parameters of the E-STA to be extracted, which have been used to update the E-STA finite element model (FEM), without the need for a traditional fixed base modal survey. This innovative approach provided considerable program cost and test schedule savings. This paper documents this modal survey, which includes the modal pretest analysis sensor selection, the fixed base methodology using measured constraint shapes as virtual references and measured frequency response functions, and post-survey comparison between measured and analysis fixed base modal parameters.

  3. Terminal hospitalizations of nursing home residents: does facility increasing the rate of do not resuscitate orders reduce them?

    PubMed

    Teno, Joan M; Gozalo, Pedro; Mitchell, Susan L; Bynum, Julie P W; Dosa, David; Mor, Vincent

    2011-06-01

    Terminal hospitalizations are costly and often avoidable with appropriate advance care planning. This study examined the association between advance care planning, as measured by facility rate of do not resuscitate (DNR) orders in U.S. nursing homes (NHs) and changes in terminal hospitalization rates. Retrospective cohort study of the changing prevalence of DNR orders in U.S. NHs. Using a fixed effect multivariate model, we examined whether increasing facility rate of DNR orders correlates with reductions in terminal hospitalizations in the last week of life, controlling for changes in facility characteristics (staffing, use of NP/PA, case mix of nursing residents, admission volume, racial composition, payer mix). The average facility rate of terminal hospitalizations was 15.5%, fluctuating between 1999 (15.0%) and 2007 (14.8%). NHs starting with low rates of DNR orders that increased their rates had fewer terminal hospital admissions in 2007 (11.2%) than facilities with continuously low DNR usage. Even after applying a multivariate fixed effect model, the effect of changes in facility DNR order rate on terminal hospitalization was -0.056 (95% confidence interval: -0.061, -0.050), indicating that for every 10% increase in DNR orders there was 0.56% decrease in terminal hospitalizations. This rate can be compared with the increase of 0.70% in the terminal hospitalization rate when an NH became disproportionately dependent on Medicaid funding or the 0.40% decrease in terminal hospitalization rate associated with adding a nurse practitioner to the clinical staff complement. NHs that changed their culture of decision making by increasing their facility rate of DNR orders decreased their rate of terminal hospitalizations. Copyright © 2011 U.S. Cancer Pain Relief Committee. Published by Elsevier Inc. All rights reserved.

  4. STS-26 crew trains in JSC fixed-based (FB) shuttle mission simulator (SMS)

    NASA Technical Reports Server (NTRS)

    1987-01-01

    STS-26 Discovery, Orbiter Vehicle (OV) 103, crewmembers (left to right) Commander Frederick H. Hauck, Pilot Richard O. Covey, Mission Specialist (MS) George D. Nelson, MS David C. Hilmers, and MS John M. Lounge pose on the middeck in fixed-based (FB) shuttle mission simulator (SMS) located in JSC Mission Simulation and Training Facility Bldg 5. A simulation for their anticipated June 1988 flight began 10-20-87.

  5. STS-29 Commander Coats in JSC fixed base (FB) shuttle mission simulator (SMS)

    NASA Technical Reports Server (NTRS)

    1986-01-01

    STS-29 Discovery, Orbiter Vehicle (OV) 103, Commander Michael L. Coats sits at commanders station forward flight deck controls in JSC fixed base (FB) shuttle mission simulator (SMS). Coats, wearing communications kit assembly headset and flight coveralls, looks away from forward control panels to aft flight deck. Pilots station seat back appears in foreground. FB-SMS is located in JSC Mission Simulation and Training Facility Bldg 5.

  6. STS-26 Commander Hauck in fixed based (FB) shuttle mission simulator (SMS)

    NASA Technical Reports Server (NTRS)

    1988-01-01

    STS-26 Discovery, Orbiter Vehicle (OV) 103, Commander Frederick H. Hauck, wearing comunications kit assembly headset and seated in the commanders seat on forward flight deck, looks over his shoulder toward the aft flight deck. A flight data file (FDF) notebook rests on his lap. The STS-26 crew is training in the fixed base (FB) shuttle mission simulator (SMS) located in JSC Mission Simulation and Training Facility Bldg 5.

  7. Asset Management: Roof Maintenance and Facility Energy Retrofits

    DTIC Science & Technology

    2012-03-01

    vapor low emission coatings. Floor finishes completed in ceramic stone tile were the most efficient floor coverings. Fixed insulated fiberglass window...been coined Asset Management which utilizes organizational levels of service, business case analysis, and risk analysis to address urgent...Force have left a number of facility systems such as roofs at risk to disrepair due to a lack of maintenance. Under the principles of asset

  8. 36 CFR 327.3 - Vessels.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., community or corporate docks, or at any fixed or permanent mooring point, may only be used for overnight... floating or stationary mooring facilities on, adjacent to, or interfering with a buoy, channel marker or...

  9. Validation of RNA-based molecular clonotype analysis for virus-specific CD8+ T-cells in formaldehyde-fixed specimens isolated from peripheral blood

    PubMed Central

    van Bockel, David; Price, David A.; Asher, Tedi E.; Venturi, Vanessa; Suzuki, Kazuo; Warton, Kristina; Davenport, Miles P.; Cooper, David A.; Douek, Daniel C.; Kelleher, Anthony D.

    2007-01-01

    Recent advances in the field of molecular clonotype analysis have enabled detailed repertoire characterization of viably isolated antigen-specific T cell populations directly ex vivo. However, in the absence of a biologically contained FACS facility, peripheral blood mononuclear cell (PBMC) preparations derived from patients infected with agents such as HIV must be formaldehyde fixed to inactivate the pathogen; this procedure adversely affects nucleic acid template quality. Here, we developed and validated a method to amplify and sequence mRNA species derived from formaldehyde fixed PBMC specimens. Antigen-specific CD8+ cytotoxic T-lymphocyte populations were identified with standard fluorochrome-conjugated peptide-major histocompatibility complex class I tetramers refolded around synthetic peptides representing immunodominant epitopes from HIV p24 Gag (KRWII[M/L]GLNK/HLA B*2705) and CMV pp65 (NLVPMVATV/HLA A*0201 and TPRVTGGGAM/HLA B*0702), and acquired in separate laboratories with or without fixation. In the presence of proteinase K pre-treatment, the observed antigen-specific CD8+ T-cell repertoire determined by molecular clonotype analysis was statistically no different whether derived from fixed or unfixed PBMC. However, oligo-dT recovery methods were not suitable for use with fixed tissue as significant skewing of clonotypic representation was observed. Thus, we have developed a reliable RNA-based method for molecular clonotype analysis that is compatible with formaldehyde fixation and therefore suitable for use with primary human samples isolated by FACS outside the context of a biological safety level 3 containment facility. PMID:17716684

  10. STS-26 crew trains in JSC fixed-based (FB) shuttle mission simulator (SMS)

    NASA Technical Reports Server (NTRS)

    1987-01-01

    STS-26 Discovery, Orbiter Vehicle (OV) 103, mission specialists pose on aft flight deck in fixed-based (FB) shuttle mission simulator (SMS) located in JSC Mission Simulation and Training Facility Bldg 5. Left to right, Mission Specialist (MS) John M. Lounge, MS George D. Nelson, and MS David C. Hilmers await start of FB-SMS simulation. The long simulation, part of the training for their anticipated June 1988 flight, began 10-20-87.

  11. STS-26 crew trains in JSC fixed-based (FB) shuttle mission simulator (SMS)

    NASA Technical Reports Server (NTRS)

    1987-01-01

    STS-26 Discovery, Orbiter Vehicle (OV) 103, Commander Frederick H. Hauck (left) and Pilot Richard O. Covey train in JSC fixed-based (FB) shuttle mission simulator (SMS) located in the Mission Simulation and Training Facility Bldg 5. On FB-SMS flight deck, Hauck and Covey man their respective stations. Mission Specialist (MS) David C. Hilmers is partially visible in the foreground. A simulation for their anticipated June 1988 flight began 10-20-87.

  12. STS-26 Commander Hauck in fixed based (FB) shuttle mission simulator (SMS)

    NASA Technical Reports Server (NTRS)

    1988-01-01

    STS-26 Discovery, Orbiter Vehicle (OV) 103, Commander Frederick H. Hauck, wearing comunications kit assembly headset, checks control panel data while seated in the commanders seat on forward flight deck. A flight data file (FDF) notebook rests on his lap. A portable computer (laptop) is positioned on the center console. The STS-26 crew is training in the fixed base (FB) shuttle mission simulator (SMS) located in JSC Mission Simulation and Training Facility Bldg 5.

  13. Development of a Knowledge-Based System Approach for Decision Making in Construction Projects

    DTIC Science & Technology

    1992-05-01

    a generic model for an administrative facility and medical facility with predefined fixed building systems based on Air Force criteria and past...MAINTENANCE HANGAR (MEDIUM BAY) CORROSION CONTROL HANGAR (HIGH BAY) FUEL SYSTEM MAINTENANCE HANGAR (MEDIUM BAY) MEDICAL MODEL 82 Table 5-1--continued...BUILDING SUPPORT MEDICAL LOGISTICS MEDICAL TOTAL 85 Table 5-2--continued MISSILE ASSEMBLY AND MAINTENANCE BUILDING TOTAL MISSILE LOADING AND UNLOADING

  14. DSN Array Simulator

    NASA Technical Reports Server (NTRS)

    Tikidjian, Raffi; Mackey, Ryan

    2008-01-01

    The DSN Array Simulator (wherein 'DSN' signifies NASA's Deep Space Network) is an updated version of software previously denoted the DSN Receive Array Technology Assessment Simulation. This software (see figure) is used for computational modeling of a proposed DSN facility comprising user-defined arrays of antennas and transmitting and receiving equipment for microwave communication with spacecraft on interplanetary missions. The simulation includes variations in spacecraft tracked and communication demand changes for up to several decades of future operation. Such modeling is performed to estimate facility performance, evaluate requirements that govern facility design, and evaluate proposed improvements in hardware and/or software. The updated version of this software affords enhanced capability for characterizing facility performance against user-defined mission sets. The software includes a Monte Carlo simulation component that enables rapid generation of key mission-set metrics (e.g., numbers of links, data rates, and date volumes), and statistical distributions thereof as functions of time. The updated version also offers expanded capability for mixed-asset network modeling--for example, for running scenarios that involve user-definable mixtures of antennas having different diameters (in contradistinction to a fixed number of antennas having the same fixed diameter). The improved version also affords greater simulation fidelity, sufficient for validation by comparison with actual DSN operations and analytically predictable performance metrics.

  15. Alternative Fuels Research Laboratory

    NASA Technical Reports Server (NTRS)

    Surgenor, Angela D.; Klettlinger, Jennifer L.; Nakley, Leah M.; Yen, Chia H.

    2012-01-01

    NASA Glenn has invested over $1.5 million in engineering, and infrastructure upgrades to renovate an existing test facility at the NASA Glenn Research Center (GRC), which is now being used as an Alternative Fuels Laboratory. Facility systems have demonstrated reliability and consistency for continuous and safe operations in Fischer-Tropsch (F-T) synthesis and thermal stability testing. This effort is supported by the NASA Fundamental Aeronautics Subsonic Fixed Wing project. The purpose of this test facility is to conduct bench scale F-T catalyst screening experiments. These experiments require the use of a synthesis gas feedstock, which will enable the investigation of F-T reaction kinetics, product yields and hydrocarbon distributions. Currently the facility has the capability of performing three simultaneous reactor screening tests, along with a fourth fixed-bed reactor for catalyst activation studies. Product gas composition and performance data can be continuously obtained with an automated gas sampling system, which directly connects the reactors to a micro-gas chromatograph (micro GC). Liquid and molten product samples are collected intermittently and are analyzed by injecting as a diluted sample into designated gas chromatograph units. The test facility also has the capability of performing thermal stability experiments of alternative aviation fuels with the use of a Hot Liquid Process Simulator (HLPS) (Ref. 1) in accordance to ASTM D 3241 "Thermal Oxidation Stability of Aviation Fuels" (JFTOT method) (Ref. 2). An Ellipsometer will be used to study fuel fouling thicknesses on heated tubes from the HLPS experiments. A detailed overview of the test facility systems and capabilities are described in this paper.

  16. A review of the Fermilab fixed-target program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rameika, R.

    1994-12-01

    All eyes are now on the Fermilab collider program as the intense search for the top quark continues. Nevertheless, Fermilab`s long tradition of operating a strong, diverse physics program depends not only on collider physics but also on effective use of the facilities the Laboratory was founded on, the fixed-target beamlines. In this talk the author presents highlights of the Fermilab fixed-target program from its (not too distant) past, (soon to be) present, and (hopefully, not too distant) future program. The author concentrates on those experiments which are unique to the fixed-target program, in particular hadron structure measurements which usemore » the varied beams and targets available in this mode and the physics results from kaon, hyperon and high statistics charm experiments which are not easily accessible in high p{sub T} hadron collider detectors.« less

  17. 33 CFR 140.103 - Annual inspection of fixed OCS facilities.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...), inspections by Coast Guard marine inspectors and Bureau of Ocean Energy Management, Regulation, and... Officer in Charge, Marine Inspection. A copy of the completed form must be kept for 2 years after the...

  18. 33 CFR 140.103 - Annual inspection of fixed OCS facilities.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...), inspections by Coast Guard marine inspectors and Bureau of Ocean Energy Management, Regulation and Enforcement..., Marine Inspection. A copy of the completed form must be kept for 2 years after the inspection under...

  19. 33 CFR 140.103 - Annual inspection of fixed OCS facilities.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...), inspections by Coast Guard marine inspectors and Bureau of Ocean Energy Management, Regulation and Enforcement..., Marine Inspection. A copy of the completed form must be kept for 2 years after the inspection under...

  20. STS-46 crewmembers participate in Fixed Base (FB) SMS training at JSC

    NASA Technical Reports Server (NTRS)

    1992-01-01

    STS-46 Atlantis, Orbiter Vehicle (OV) 104, Pilot Andrew M. Allen hands Mission Specialist (MS) and Payload Commander (PLC) Jeffrey A. Hoffman checklists from middeck locker MF43E during training session in JSC's fixed base (FB) shuttle mission simulator (SMS) located in Mission Simulation and Training Facility Bldg 5. European Space Agency (ESA) MS Claude Nicollier outfitted with communications kit assembly headset (HDST) and equipment looks beyond Hoffman to the opposite side of the middeck.

  1. STS-46 crewmembers participate in Fixed Base (FB) SMS training at JSC

    NASA Technical Reports Server (NTRS)

    1992-01-01

    STS-46 Atlantis, Orbiter Vehicle (OV) 104, Mission Specialist (MS) and Payload Commander (PLC) Jeffrey A. Hoffman, standing at the interdeck access ladder, explains procedures to backup Italian Payload Specialist Umberto Guidoni (center) and Italian Payload Specialist Franco Malerba (right) on the middeck of JSC's fixed base (FB) shuttle mission simulator (SMS). Behind them, MS Marsha S. Ivins reviews a cheklist. Participants are wearing communications kit assembly lightweight headsets (HDSTs). FB-SMS is located in JSC's Mission Simulation and Training Facility Bldg 5.

  2. Accessibility to health care facilities in Montreal Island: an application of relative accessibility indicators from the perspective of senior and non-senior residents.

    PubMed

    Paez, Antonio; Mercado, Ruben G; Farber, Steven; Morency, Catherine; Roorda, Matthew

    2010-10-25

    Geographical access to health care facilities is known to influence health services usage. As societies age, accessibility to health care becomes an increasingly acute public health concern. It is known that seniors tend to have lower mobility levels, and it is possible that this may negatively affect their ability to reach facilities and services. Therefore, it becomes important to examine the mobility situation of seniors vis-a-vis the spatial distribution of health care facilities, to identify areas where accessibility is low and interventions may be required. Accessibility is implemented using a cumulative opportunities measure. Instead of assuming a fixed bandwidth (i.e. a distance threshold) for measuring accessibility, in this paper the bandwidth is defined using model-based estimates of average trip length. Average trip length is an all-purpose indicator of individual mobility and geographical reach. Adoption of a spatial modelling approach allows us to tailor these estimates of travel behaviour to specific locations and person profiles. Replacing a fixed bandwidth with these estimates permits us to calculate customized location- and person-based accessibility measures that allow inter-personal as well as geographical comparisons. The case study is Montreal Island. Geo-coded travel behaviour data, specifically average trip length, and relevant traveller's attributes are obtained from the Montreal Household Travel Survey. These data are complemented with information from the Census. Health care facilities, also geo-coded, are extracted from a comprehensive business point database. Health care facilities are selected based on Standard Industrial Classification codes 8011-21 (Medical Doctors and Dentists). Model-based estimates of average trip length show that travel behaviour varies widely across space. With the exception of seniors in the downtown area, older residents of Montreal Island tend to be significantly less mobile than people of other age cohorts. The combination of average trip length estimates with the spatial distribution of health care facilities indicates that despite being more mobile, suburban residents tend to have lower levels of accessibility compared to central city residents. The effect is more marked for seniors. Furthermore, the results indicate that accessibility calculated using a fixed bandwidth would produce patterns of exposure to health care facilities that would be difficult to achieve for suburban seniors given actual mobility patterns. The analysis shows large disparities in accessibility between seniors and non-seniors, between urban and suburban seniors, and between vehicle owning and non-owning seniors. This research was concerned with potential accessibility levels. Follow up research could consider the results reported here to select case studies of actual access and usage of health care facilities, and related health outcomes.

  3. 78 FR 11257 - Self-Regulatory Organizations; The NASDAQ Stock Market LLC; Notice of Filing and Immediate...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-15

    ... facility for executing and routing standardized equity and index options. The Exchange also proposes a... using the Financial Information Exchange (``FIX'') protocol. The Exchange also proposes to define the...

  4. Broadband wireless, integrated services, and their application to intelligent transportation systems

    DOT National Transportation Integrated Search

    2000-06-01

    This paper introduces some of the newer broadband wireless communications alternatives and describes how they could be used to provide high-speed connections between fixed, transportable, and mobile facilities. We also describe the new integrated ser...

  5. CFOs are passing too many bucks.

    PubMed

    Pallarito, K

    1995-06-19

    Although finance executives at not-for-profit hospitals and healthcare systems don't have a great record when it comes to fixed-asset returns, more CFOs are getting creative in pursuit of new methods to make their facilities' assets work harder.

  6. Handicapped and Elderly Vertical Movement Assessment Study

    DOT National Transportation Integrated Search

    1976-02-01

    The report discusses the selection and assessment of seven (7) types of vertical movement devices for potential use in older types of fixed rail urban mass transit facilities. The potential utilization of these devices is directed towards an increase...

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yokosawa, A.

    We summarize activities concerning the Fermilab polarized beams. They include a description of the polarized-beam facility, measurements of beam polarization by polarimeters, asymmetry measurements in the production at large x, and experiments with polarized beams during the next fixed-target period. 8 refs., 9 figs.

  8. Military Personnel: Enhanced Collaboration and Process Improvements Needed for Determining Military Treatment Facility Medical Personnel Requirements

    DTIC Science & Technology

    2010-07-01

    Department of Defense (DOD) are in great demand due to projected nationwide medical personnel shortages over the next decade and are essential to...for the first year, in order to assist the services in addressing near- term personnel shortages . It also provides a consistent staffing standard...dentists, medical service corps, and veterinarians , to name a few, at the work center level across Army fixed military treatment facilities. The model uses

  9. Development and validation of the crew-station system-integration research facility

    NASA Technical Reports Server (NTRS)

    Nedell, B.; Hardy, G.; Lichtenstein, T.; Leong, G.; Thompson, D.

    1986-01-01

    The various issues associated with the use of integrated flight management systems in aircraft were discussed. To address these issues a fixed base integrated flight research (IFR) simulation of a helicopter was developed to support experiments that contribute to the understanding of design criteria for rotorcraft cockpits incorporating advanced integrated flight management systems. A validation experiment was conducted that demonstrates the main features of the facility and the capability to conduct crew/system integration research.

  10. Demonstration and Validation of a Waste-to-Energy Conversion System for Fixed DoD Installations

    DTIC Science & Technology

    2013-09-01

    hydrocarbon HVAC heating, ventilation , and air conditioning HX heat exchanger I/O input/output ISO International Organization for Standardization...DEMONSTRATION In 2011, renewable energy accounted for just 9% of total energy consumption in the United States, and just 5% (or 0.45% overall) of that (477...operations and facilities.3 Facility energy costs accounted for ~21% ($4.1 billion). DoD has made great progress in reducing its energy consumption for

  11. Implementing a comprehensive cost information system in rural health facilities: the case of Nouna health district, Burkina Faso.

    PubMed

    Flessa, Steffen; Kouyaté, Bocar

    2006-09-01

    To present first findings of a cost-of-illness (COI) information system implemented in Nouna health district, Burkina Faso. The entire project will include household and provider tangible COI, whereas this article concentrates on the development of a provider cost information system in rural first-line health facilities. Special forms and reports are prepared to routinely collect capital and recurrent costs of first-line facilities. Inventory lists are designed, and buildings and equipment are assessed by engineers. Total, fixed, variable and average costs are calculated for 15 rural health centres with five cost centres: general outpatient consultation, ambulatory nursing care, deliveries, immunization and other services (neonatal consultation, child care and family planning). In 2003, the average costs per service unit were 1.34 US$ for a general consultation, 0.51 US$ for ambulatory nursing care, 6.73 US$ per delivery, 3.64 US$ per vaccination and 1.11 US$ per service unit of other care. On average, a health centre consumes 29,900 US$ per year for a catchment population of 10,000 inhabitants. The major share of costs is fixed and does not depend on the workload of the health centre. Consequently, the costs of first-line facilities will hardly increase if the demand for health services rises. These findings can be used to improve the health financing in Nouna health district, Burkina Faso.

  12. An evaluation of proposed acoustic treatments for the NASA LaRC 4 x 7 meter wind tunnel

    NASA Technical Reports Server (NTRS)

    Abrahamson, A. L.

    1985-01-01

    The NASA LaRC 4 x 7 Meter Wind Tunnel is an existing facility specially designed for powered low speed (V/STOL) testing of large scale fixed wing and rotorcraft models. The enhancement of the facility for scale model acoustic testing is examined. The results are critically reviewed and comparisons are drawn with a similar wind tunnel (the DNW Facility in the Netherlands). Discrepancies observed in the comparison stimulated a theoretical investigation using the acoustic finite element ADAM System, of the ways in which noise propagating around the tunnel circuit radiates into the open test section. The reasons for the discrepancies noted above are clarified and assists in the selection of acoustic treatment options for the facility.

  13. An airborne intensive care facility (fixed wing).

    PubMed

    Gilligan, J E; Goon, P; Maughan, G; Griggs, W; Haslam, R; Scholten, A

    1996-04-01

    A fixed-wing aircraft (Beechcraft KingAir B200 C) fitted as an airborne intensive care facility is described. It completed 2000 missions from 1987-1992 for distances up to 1300 km. Features include: 1. Space for carriage of two stretchers, medical cabin crew of up to five persons and equipment and two-pilot operation if necessary. A third stretcher may be carried in emergencies. 2. Two CARDIOCAP (TM) fixed monitors for ECG, invasive and noninvasive pressures pulse oximetry and end-tidal C02 plus SIEMENS 630(TM)/PROPAQ(TM) compact monitors for the ground transport phase of missions, or the total duration. 3. A medical oxygen reservoir of 4650 litres sufficient for two patients on IPPV with FiO2 = 1.0 for a four-hour trip. The medical suction system is powered from the engine or a vacuum pump. 4. Other medical equipment and drugs in portable packs, for ground transport and resuscitation needs and for replenishment by nursing staff at the parent hospitals. 5. Stretchers compatible with helicopter and road ambulance vehicles used. 6. A stretcher loading device energized from the aircraft, operating through a wide (cargo) door. 7. Provision of 24Ov AC (alternating current) and 28v DC (direct current) electrical energy. 8. Pressurization and climate control. 9. Satisfactory aviation performance for conditions encountered, with single-pilot operation.

  14. 33 CFR 101.120 - Alternatives.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Alternatives. 101.120 Section 101... MARITIME SECURITY: GENERAL General § 101.120 Alternatives. (a) Alternative Security Agreements. (1) The U.S... Alternative Security Arrangements covering short international voyages on fixed routes between facilities...

  15. Optical laboratory facilities at the Finnish Meteorological Institute - Arctic Research Centre

    NASA Astrophysics Data System (ADS)

    Lakkala, Kaisa; Suokanerva, Hanne; Matti Karhu, Juha; Aarva, Antti; Poikonen, Antti; Karppinen, Tomi; Ahponen, Markku; Hannula, Henna-Reetta; Kontu, Anna; Kyrö, Esko

    2016-07-01

    This paper describes the laboratory facilities at the Finnish Meteorological Institute - Arctic Research Centre (FMI-ARC, http://fmiarc.fmi.fi). They comprise an optical laboratory, a facility for biological studies, and an office. A dark room has been built, in which an optical table and a fixed lamp test system are set up, and the electronics allow high-precision adjustment of the current. The Brewer spectroradiometer, NILU-UV multifilter radiometer, and Analytical Spectral Devices (ASD) spectroradiometer of the FMI-ARC are regularly calibrated or checked for stability in the laboratory. The facilities are ideal for responding to the needs of international multidisciplinary research, giving the possibility to calibrate and characterize the research instruments as well as handle and store samples.

  16. A simulated lightning effects test facility for testing live and inert missiles and components

    NASA Technical Reports Server (NTRS)

    Craven, Jeffery D.; Knaur, James A.; Moore, Truman W., Jr.; Shumpert, Thomas H.

    1991-01-01

    Details of a simulated lightning effects test facility for testing live and inert missiles, motors, and explosive components are described. The test facility is designed to simulate the high current, continuing current, and high rate-of-rise current components of an idealized direct strike lightning waveform. The Lightning Test Facility was in operation since May, 1988, and consists of: 3 separate capacitor banks used to produce the lightning test components; a permanently fixed large steel safety cage for retaining the item under test (should it be ignited during testing); an earth covered bunker housing the control/equipment room; a charge/discharge building containing the charging/discharging switching; a remotely located blockhouse from which the test personnel control hazardous testing; and interconnecting cables.

  17. STS-26 simulation activities in JSC Mission Control Center (MCC)

    NASA Technical Reports Server (NTRS)

    1987-01-01

    Overall view of JSC Mission Control Center (MCC) Bldg 30 Flight Control Room (FCR) during Flight Day 1 of STS-26 integrated simulations in progress between MCC and JSC Mission Simulation and Training Facility Bldg 5 fixed-base (FB) shuttle mission simulator (SMS).

  18. 42 CFR 485.51 - Definition.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...” means a nonresidential facility that— (a) Is established and operated exclusively for the purpose of..., disabled, or sick persons, at a single fixed location, by or under the supervision of a physician except as.... May provide influenza, pneumococcal and Hepatitis B vaccines provided the applicable conditions of...

  19. Fixing Maintenance Productivity.

    ERIC Educational Resources Information Center

    Fickes, Michael

    2003-01-01

    Describes how one university's facility managers use Nextel communications technology in conjunction with a Famis Software maintenance management system to improve the productivity of its maintenance technicians. The system uses a wireless Internet connection to automate the flow of work order information to and from technicians. The key to these…

  20. Seismic analysis of the Mirror Fusion Test Facility: soil structure interaction analyses of the Axicell vacuum vessel. Revision 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maslenikov, O.R.; Mraz, M.J.; Johnson, J.J.

    1986-03-01

    This report documents the seismic analyses performed by SMA for the MFTF-B Axicell vacuum vessel. In the course of this study we performed response spectrum analyses, CLASSI fixed-base analyses, and SSI analyses that included interaction effects between the vessel and vault. The response spectrum analysis served to benchmark certain modeling differences between the LLNL and SMA versions of the vessel model. The fixed-base analysis benchmarked the differences between analysis techniques. The SSI analyses provided our best estimate of vessel response to the postulated seismic excitation for the MFTF-B facility, and included consideration of uncertainties in soil properties by calculating responsemore » for a range of soil shear moduli. Our results are presented in this report as tables of comparisons of specific member forces from our analyses and the analyses performed by LLNL. Also presented are tables of maximum accelerations and relative displacements and plots of response spectra at various selected locations.« less

  1. Study of the damping characteristics of general aviation aircraft panels and development of computer programs to calculate the effectiveness of interior noise control treatment, part 1

    NASA Technical Reports Server (NTRS)

    Navaneethan, R.; Hunt, J.; Quayle, B.

    1982-01-01

    Tests were carried out on 20 inch x 20 inch panels at different test conditions using free-free panels, clamped panels, and panels as installed in the KU-FRL acoustic test facility. Tests with free-free panels verified the basic equipment set-up and test procedure. They also provided a basis for comparison. The results indicate that the effect of installed panels is to increase the damping ratio at the same frequency. However, a direct comparison is not possible, as the fundamental frequency of a free-free panel differs from the resonance frequency of the panel when installed. The damping values of panels installed in the test facility are closer to the damping values obtained with fixed-fixed panels. Effects of damping tape, stiffeners, and bonded and riveted edged conditions were also investigated. Progress in the development of a simple interior noise level control program is reported.

  2. Coast Guard Aircraft: Transfer of Fixed-Wing C-27J Aircraft Is Complex and Further Fleet Purchases Should Coincide with Study Results

    DTIC Science & Technology

    2015-03-01

    C-27J to the Coast Guard. This report assesses (1) the status of the transfer and risks the Coast Guard faces in fielding the transferred aircraft...had transferred 2 of the 14 C-27J aircraft it is receiving from the Air Force to its aircraft maintenance facility, with plans to field 14 fully...Coast Guard continues to receive these aircraft in the near term, the capability and cost of the Coast Guard’s fixed-wing fleet runs the risk of being

  3. Nursing home prices and market structure: the effect of assisted living industry expansion.

    PubMed

    Bowblis, John R

    2014-01-01

    Since the 1990s, there has been substantial expansion of facility-based alternatives to nursing home care, such as assisted living facilities. This paper analyzes the relationship between expansion of the assisted living industry, nursing home market structure and nursing home private pay prices using a two-year panel of nursing homes in the State of Ohio. Fixed effect regressions suggest that the expansion of assisted living facilities are associated with increased nursing home concentration, but find no effect on private pay nursing home prices. This would be consistent with assisted livings reducing demand for nursing homes by delaying entry into a nursing home, though assisted livings are not direct competitors of nursing homes.

  4. The NASA Altitude Wind Tunnel (AWT): Its role in advanced icing research and development

    NASA Technical Reports Server (NTRS)

    Blaha, B. J.; Shaw, R. J.

    1985-01-01

    Currently experimental aircraft icing research is severely hampered by limitations of ground icing simulation facilities. Existing icing facilities do not have the size, speed, altitude, and icing environment simulation capabilities to allow accurate studies to be made of icing problems occurring for high speed fixed wing aircraft and rotorcraft. Use of the currently dormant NASA Lewis Altitude Wind Tunnel (AWT), as a proposed high speed propulsion and adverse weather facility, would allow many such problems to be studied. The characteristics of the AWT related to adverse weather simulation and in particular to icing simulation are discussed, and potential icing research programs using the AWT are also included.

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Voyles, Jimmy

    Individual datastreams from instrumentation at the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility fixed and mobile research observatories (sites) are collected and routed to the ARM Data Center (ADC). The Data Management Facility (DMF), a component of the ADC, executes datastream processing in near-real time. Processed data are then delivered approximately daily to the ARM Data Archive, also a component of the ADC, where they are made freely available to the research community. For each instrument, ARM calculates the ratio of the actual number of processed data records received daily at the ARM Data Archivemore » to the expected number of data records. DOE requires national user facilities to report time-based operating data.« less

  6. Application of the API/NPRA SVA methodology to transportation security issues.

    PubMed

    Moore, David A

    2006-03-17

    Security vulnerability analysis (SVA) is becoming more prevalent as the issue of chemical process security is of greater concern. The American Petroleum Institute (API) and the National Petrochemical and Refiner's Association (NPRA) have developed a guideline for conducting SVAs of petroleum and petrochemical facilities in May 2003. In 2004, the same organizations enhanced the guidelines by adding the ability to evaluate transportation security risks (pipeline, truck, and rail). The importance of including transportation and value chain security in addition to fixed facility security in a SVA is that these issues may be critically important to understanding the total risk of the operation. Most of the SVAs done using the API/NPRA SVA and other SVA methods were centered on the fixed facility and the operations within the plant fence. Transportation interfaces alone are normally studied as a part of the facility SVA, and the entire transportation route impacts and value chain disruption are not commonly considered. Particularly from a national, regional, or local infrastructure analysis standpoint, understanding the interdependencies is critical to the risk assessment. Transportation risks may include weaponization of the asset by direct attack en route, sabotage, or a Trojan Horse style attack into a facility. The risks differ in the level of access control and the degree of public exposures, as well as the dynamic nature of the assets. The public exposures along the transportation route need to be carefully considered. Risks may be mitigated by one of many strategies including internment, staging, prioritization, conscription, or prohibition, as well as by administrative security measures and technology for monitoring and isolating the assets. This paper illustrates how these risks can be analyzed by the API/NPRA SVA methodology. Examples are given of a pipeline operation, and other examples are found in the guidelines.

  7. Development of feedback-speed-control system of fixed-abrasive tool for mat-surface fabrication

    NASA Astrophysics Data System (ADS)

    Yanagihara, K.; Kita, R.

    2018-01-01

    This study deals with the new method to fabricate a mat-surface by using fixed-abrasive tool. Mat-surface is a surface with microscopic irregularities whose dimensions are close to the wavelengths of visible light (400-700 nanometers). In order to develop the new method to fabricate mat-surface without pre-masking and large scale back up facility, utilization of fixed-abrasive tool is discussed. The discussion clarifies that abrasives in shot blasting are given kinetic energy along to only plunge-direction while excluding traverse-direction. If the relative motion between tool and work in fixed-abrasive process can be realized as that in blasting, mat-surface will be accomplished with fixed-abrasive process. To realize the proposed idea, new surface-fabrication system to which is adopted feedback-speed-control of abrasive wheel has been designed. The system consists of micro-computer unit (MPU), work-speed sensor, fixed-abrasive wheel, and wheel driving unit. The system can control relative speed between work and wheel in optimum range to produce mat-surface. Finally experiment to verify the developed system is carried out. The results of experiments show that the developed system is effective and it can produce the surface from grinding to mat-surface seamlessly.

  8. 49 CFR 268.1 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... environmental impact statement which is required pursuant to §§ 268.3. Eligible project costs means the costs of preconstruction planning activities and the capital cost of the fixed guideway infrastructure of a Maglev project... storage, repair, and maintenance facilities, but eligible project costs do not include the cost of...

  9. 76 FR 28121 - Notice of Passenger Facility Charge (PFC) Approvals and Disapprovals

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-13

    .... Security cameras. Snow removal equipment. Update airport master plan study phases I and II. Obstruction... general aviation area. Preconditioned air and fixed ground power. Airfield environmental assessment... Withdrawal: April 19, 2011. Decision Date: April 25, 2011. FOR FURTHER INFORMATION CONTACT: Anna Guss...

  10. Forecasting Water Use on Fixed Army Installations within the Contiguous United States.

    DTIC Science & Technology

    1984-06-22

    Laundromats Car wash L Cafeterias/restaurants Main clubs and annexes Industrial Public/Institutional Vehicle and aircraft wash facilities Offices and...residents, who may prefer to use laundromats located elsewhere. Training Classrooms and other special buildings in which instruction is given make up this

  11. 47 CFR 1.7001 - Scope and content of filed reports.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... facilities that it obtained the right to use from other entities as dark fiber or satellite transponder... from other entities as dark fiber or satellite transponder capacity. (b) All commercial and government....C. 153 (1)), cable television companies, fixed wireless providers, terrestrial and satellite mobile...

  12. Voluntary medical male circumcision scale-up in Nyanza, Kenya: evaluating technical efficiency and productivity of service delivery.

    PubMed

    Omondi Aduda, Dickens S; Ouma, Collins; Onyango, Rosebella; Onyango, Mathews; Bertrand, Jane

    2015-01-01

    Voluntary medical male circumcision (VMMC) service delivery is complex and resource-intensive. In Kenya's context there is still paucity of information on resource use vis-à-vis outputs as programs scale up. Knowledge of technical efficiency, productivity and potential sources of constraints is desirable to improve decision-making. To evaluate technical efficiency and productivity of VMMC service delivery in Nyanza in 2011/2012 using data envelopment analysis. Comparative process evaluation of facilities providing VMMC in Nyanza in 2011/2012 using output orientated data envelopment analysis. Twenty one facilities were evaluated. Only 1 of 7 variables considered (total elapsed operation time) significantly improved from 32.8 minutes (SD 8.8) in 2011 to 30 minutes (SD 6.6) in 2012 (95%CI = 0.0350-5.2488; p = 0.047). Mean scale technical efficiency significantly improved from 91% (SD 19.8) in 2011 to 99% (SD 4.0) in 2012 particularly among outreach compared to fixed service delivery facilities (CI -31.47959-4.698508; p = 0.005). Increase in mean VRS technical efficiency from 84% (SD 25.3) in 2011 and 89% (SD 25.1) in 2012 was not statistically significant. Benchmark facilities were #119 and #125 in 2011 and #103 in 2012. Malmquist Productivity Index (MPI) at fixed facilities declined by 2.5% but gained by 4.9% at outreach ones by 2012. Total factor productivity improved by 83% (p = 0.032) in 2012, largely due to progress in technological efficiency by 79% (p = 0.008). Significant improvement in scale technical efficiency among outreach facilities in 2012 was attributable to accelerated activities. However, ongoing pure technical inefficiency requires concerted attention. Technological progress was the key driver of service productivity growth in Nyanza. Incorporating service-quality dimensions and using stepwise-multiple criteria in performance evaluation enhances comprehensiveness and validity. These findings highlight site-level resource use and sources of variations in VMMC service productivity, which are important for program planning.

  13. Assessing community exposure to hazardous air pollutants by combining optical remote sensing and "low-cost" sensor technologies

    NASA Astrophysics Data System (ADS)

    Pikelnaya, O.; Polidori, A.; Wimmer, R.; Mellqvist, J.; Samuelsson, J.; Marianne, E.; Andersson, P.; Brohede, S.; Izos, O.

    2017-12-01

    Industrial facilities such as refineries and oil processing facilities can be sources of chemicals adversely affecting human health, for example aromatic hydrocarbons and formaldehyde. In an urban setting, such as the South Coast Air Basin (SCAB), exposure to harmful air pollutants (HAP's) for residents of communities neighboring such facilities is of serious concern. Traditionally, exposure assessments are performed by modeling a community exposure using emission inventories and data collected at fixed air monitoring sites. However, recent field measurements found that emission inventories may underestimate HAP emissions from refineries; and HAP measurements data from fixed sites is lacking spatial resolution; as a result, the impact of HAP emissions on communities is highly uncertain. The next generation air monitoring technologies can help address these challenges. For example, dense "low-cost" sensors allow continuous monitoring of concentrations of pollutants within communities with high temporal- and spatial- resolution, and optical remote sensing (ORS) technologies offer measurements of emission fluxes and real-time ground-concentration mapping of HAPs. South Coast Air Quality Management District (SCAQMD) is currently conducting a multi-year study using ORS methods and "low-cost" Volatile Organic Compounds (VOCs) sensors to monitor HAP emissions from selected industrial facilities in the SCAB and their ambient concentrations in neighboring communities. For this purpose, quarterly mobile ORS surveys are conducted to quantify facility-wide emissions for VOCs, aromatic hydrocarbons and HCHO, and to collect ground-concentration profiles of these pollutants inside neighboring communities. Additionally, "low-cost" sensor nodes for deployment in neighborhood(s) downwind of the facilities have been developed in order to obtain long-term, granular data on neighborhood VOC concentrations, During this presentation we will discuss initial results of quarterly ORS surveys and pilot "low-cost" sensor deployments. We will also outline benefits of using a combination of mobile ORS surveys and "low-cost" sensor networks for community exposure monitoring.

  14. Co-C and Pd-C Fixed Points for the Evaluation of Facilities and Scales Realization at INRIM and NMC

    NASA Astrophysics Data System (ADS)

    Battuello, M.; Wang, L.; Girard, F.; Ang, S. H.

    2014-04-01

    Two hybrid cells for realizing the Co-C and Pd-C fixed points and constructed at Istituto Nazionale di Ricerca Metrologica (INRIM) were used for an evaluation of facilities and procedures adopted by INRIM and National Metrology Institute of Singapore (NMC) for the realization of the solid-liquid phase transitions of high-temperature fixed points and for determining their transition temperatures. Four different furnaces were used for the investigations, i.e., two single-zone furnaces, one of them of the direct-heating type, and two identical three-zone furnaces. The transition temperatures were measured at both institutes by adopting different procedures for realizing the radiation scales, i.e., at INRIM a scheme based on the extrapolation of fixed-point interpolated scales and an International Temperature Scale of 1990 (ITS-90) approach at NMC. The point of inflection (POI) of the melting curves was determined and assumed as a practical representation of the melting temperature. Different methods for deriving the POI were used, and differences as large as some hundredths of a kelvin were found with the different approaches. The POIs of the different melting curves were analyzed with respect to the different possible operative conditions with the aim of deriving reproducibility figures to improve the estimated uncertainty. As regard to the institutes inter-comparison, differences of 0.13 K and 0.29 K were found between INRIM and NMC determinations at the Co-C and Pd-C points, respectively. Such differences are compatible with the combined standard uncertainties of the comparison, which are estimated to be 0.33 K and 0.36 K at the Co-C and Pd-C points, respectively.

  15. JSC Shuttle Mission Simulator (SMS) visual system payload bay video image

    NASA Technical Reports Server (NTRS)

    1981-01-01

    This space shuttle orbiter payload bay (PLB) video image is used in JSC's Fixed Based (FB) Shuttle Mission Simulator (SMS). The image is projected inside the FB-SMS crew compartment during mission simulation training. The FB-SMS is located in the Mission Simulation and Training Facility Bldg 5.

  16. TECHNOLOGY EVALUATION REPORT: BIOLOGICAL TREATMENT OF WOOD PRESERVING SITE GROUNDWATER BY BIOTROL, INC.

    EPA Science Inventory

    This report provides the in-depth data analysis from the SITE Program's six-week demonstration of BioTrol's Aqueous Treatment System (BATS) at the MacGillis and Gibbs Company wood treatment facility in New Brighton, Minnesota. he pilot scale (5gpm), fixed-film biological system u...

  17. School Construction: Fixing Facilities

    ERIC Educational Resources Information Center

    Kennedy, Mike

    2012-01-01

    About two decades ago, a consensus began to take root among educators and policymakers that school systems in the United States could no longer afford to ignore the inadequate building conditions that made teaching and learning difficult in many classrooms. Since then, billions of dollars have been spent, and thousands of modern classrooms have…

  18. 77 FR 4989 - Turning Point Solar LLC: Notice of Availability of an Environmental Assessment

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-01

    ... constructing a 49.9 megawatt (MW) ground- mounted solar photovoltaic generating facility in Noble County, Ohio... monocrystalline photovoltaic panels mounted on fixed solar racking equipment and the construction of access roads... DEPARTMENT OF AGRICULTURE Rural Utilities Service Turning Point Solar LLC: Notice of Availability...

  19. 77 FR 31981 - Eligible Obligations, Charitable Contributions, Nonmember Deposits, Fixed Assets, Investments...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-31

    ... remove the automatic exemption from the nonmember deposits limit that had been granted to RegFlex FCUs... created a ``well capitalized standard'' based on the automatic designation criteria used in RegFlex. An... premises. ``Premises'' means any office, branch office, suboffice, service center, parking lot, facility...

  20. Not ''just'' pump and treat

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Angleberger, K; Bainer, R W

    2000-12-12

    The Lawrence Livermore National Laboratory (LLNL) has been consistently improving the site cleanup methods by adopting new philosophies, strategies and technologies to address constrained or declining budgets, lack of useable space due to a highly industrialized site, and significant technical challenges. As identified in the ROD, the preferred remedy at the LLNL Livermore Site is pump and treat, although LLNL has improved this strategy to bring the remediation of the ground water to closure as soon as possible. LLNL took the logical progression from a pump and treat system to the philosophy of ''Smart Pump and Treat'' coupled with themore » concepts of ''Hydrostratigraphic Unit Analysis,'' ''Engineered Plume Collapse,'' and ''Phased Source Remediation,'' which led to the development of new, more cost-effective technologies which have accelerated the attainment of cleanup goals significantly. Modeling is also incorporated to constantly develop new, cost-effective methodologies to accelerate cleanup and communicate the progress of cleanup to stakeholders. In addition, LLNL improved on the efficiency and flexibility of ground water treatment facilities. Ground water cleanup has traditionally relied on costly and obtrusive fixed treatment facilities. LLNL has designed and implemented various portable ground water treatment units to replace the fixed facilities; the application of each type of facility is determined by the amount of ground water flow and contaminant concentrations. These treatment units have allowed for aggressive ground water cleanup, increased cleanup flexibility, and reduced capital and electrical costs. After a treatment unit has completed ground water cleanup at one location, it can easily be moved to another location for additional ground water cleanup.« less

  1. A State-of-the-Art Contamination Effects Research and Test Facility

    NASA Technical Reports Server (NTRS)

    Olson, Keith R.; Folgner, Kelsey A.; Barrie, James D.; Villahermosa, Randy M.

    2008-01-01

    In the ongoing effort to better understand various spacecraft contamination phenomena, a new state of the art contamination effects research and test facility was designed, and recently brought on-line at The Aerospace Corporation s Space Materials Laboratory. This high vacuum test chamber employs multiple in-situ analytical techniques, making it possible to study both the qualitative and quantitative aspects of contaminant film formation in the presence or absence of VUV radiation. Adsorption and desorption kinetics, "photo-fixing efficiency", transmission loss of uniform contaminant films, light scatter from non-uniform films, and film morphology have been studied in this facility. This paper describes this new capability in detail and presents data collected from several of the analytical instruments.

  2. Atmospheric Radiation Measurement Program Climate Research Facility Operations Quarterly Report. October 1 - December 31, 2010.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sisterson, D. L.

    2011-02-01

    Individual raw datastreams from instrumentation at the Atmospheric Radiation Measurement (ARM) Climate Research Facility fixed and mobile sites are collected and sent to the Data Management Facility (DMF) at Pacific Northwest National Laboratory (PNNL) for processing in near-real time. Raw and processed data are then sent approximately daily to the ARM Archive, where they are made available to users. For each instrument, we calculate the ratio of the actual number of processed data records received daily at the Archive to the expected number of data records. The results are tabulated by (1) individual datastream, site, and month for the currentmore » year and (2) site and fiscal year (FY) dating back to 1998. The U.S. Department of Energy (DOE) requires national user facilities to report time-based operating data. The requirements concern the actual hours of operation (ACTUAL); the estimated maximum operation or uptime goal (OPSMAX), which accounts for planned downtime; and the VARIANCE [1 - (ACTUAL/OPSMAX)], which accounts for unplanned downtime. The OPSMAX time for the first quarter of FY2010 for the Southern Great Plains (SGP) site is 2097.60 hours (0.95 x 2208 hours this quarter). The OPSMAX for the North Slope Alaska (NSA) locale is 1987.20 hours (0.90 x 2208) and for the Tropical Western Pacific (TWP) locale is 1876.80 hours (0.85 x 2208). The first ARM Mobile Facility (AMF1) deployment in Graciosa Island, the Azores, Portugal, continued through this quarter, so the OPSMAX time this quarter is 2097.60 hours (0.95 x 2208). The second ARM Mobile Facility (AMF2) began deployment this quarter to Steamboat Springs, Colorado. The experiment officially began November 15, but most of the instruments were up and running by November 1. Therefore, the OPSMAX time for the AMF2 was 1390.80 hours (.95 x 1464 hours) for November and December (61 days). The differences in OPSMAX performance reflect the complexity of local logistics and the frequency of extreme weather events. It is impractical to measure OPSMAX for each instrument or datastream. Data availability reported here refers to the average of the individual, continuous datastreams that have been received by the Archive. Data not at the Archive are caused by downtime (scheduled or unplanned) of the individual instruments. Therefore, data availability is directly related to individual instrument uptime. Thus, the average percentage of data in the Archive represents the average percentage of the time (24 hours per day, 92 days for this quarter) the instruments were operating this quarter. Summary. Table 1 shows the accumulated maximum operation time (planned uptime), actual hours of operation, and variance (unplanned downtime) for the period October 1-December 31, 2010, for the fixed sites. Because the AMFs operate episodically, the AMF statistics are reported separately and not included in the aggregate average with the fixed sites. This first quarter comprises a total of 2,208 possible hours for the fixed sites and the AMF1 and 1,464 possible hours for the AMF2. The average of the fixed sites exceeded our goal this quarter. The AMF1 has essentially completed its mission and is shutting down to pack up for its next deployment to India. Although all the raw data from the operational instruments are in the Archive for the AMF2, only the processed data are tabulated. Approximately half of the AMF2 instruments have data that was fully processed, resulting in the 46% of all possible data made available to users through the Archive for this first quarter. Typically, raw data is not made available to users unless specifically requested.« less

  3. The colorimetric analysis of anti-tuberculosis fixed-dose combination tablets and capsules.

    PubMed

    Ellard, G A

    1999-11-01

    The perceived need to demonstrate whether or not the actual amounts of rifampicin, isoniazid and pyrazinamide in fixed-dose combination tablets or capsules correspond to their stated drug contents. To adapt specific, robust and simple colorimetric methods that have been previously applied to measuring plasma and urinary rifampicin, isoniazid, pyrazinamide and ethambutol concentrations to estimate tablet and capsule drug contents. The methods were applied to the analysis of 14 commercially manufactured fixed-dose combinations: two capsule and three tablet formulations containing rifampicin and isoniazid; seven tablet formulations containing rifampicin, isoniazid and pyrazinamide; and two tablet formulations containing rifampicin, isoniazid, pyrazinamide and ethambutol. All the combined formulations contained near to their stated drug contents. Replicate analyses confirmed the excellent precision of the drug analyses. Such methods are not only rapid to perform but should be practical in many Third World situations with relatively modest laboratory facilities.

  4. The Refurbishment and Upgrade of the Atmospheric Radiation Measurement Raman Lidar

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Turner, D.D.; Goldsmith, J.E.M.

    The Atmospheric Radiation Measurement Program (ARM) Climate Research Facility (ACRF) Raman lidar (CARL) is an autonomous, turn-key system that profiles water vapor, aerosols, and clouds throughout the diurnal cycle for days without attention (Goldsmith et al. 1998). CARL was first deployed to the Southern Great Plains CRF during the summer of 1996 and participated in the 1996 and 1997 water vapor intensive operational periods (IOPs). Since February 1998, the system has collected over 38,000 hrs of data (equivalent of almost 4.4 years), with an average monthly uptime of 62% during this time period. This unprecedented performance by CARL makes itmore » the premier operational Raman lidar in the world. Unfortunately, CARL began degrading in early 2002. This loss of sensitivity, which affected all observed variables, was very gradual and thus was not identified until the autumn of 2003. Analysis of the data suggested the problem was not associated with the laser or transmit portion of the system, but rather in the detection subsystem, as both the background values and the peak signals showed a marked decreases over this time period. The loss of sensitivity of a factor of 2-4, depending on the channel, resulted in higher random error in the retrieved products, such as the aerosol backscatter coefficient and water vapor mixing ratio. Figure 1 shows the random error at 2 km for aerosol backscatter coefficient (top) and water vapor mixing ratio (middle), in terms of percent of the signal for both average daytime (red) and nighttime (blue) data from 1998 to 2005. The seasonal variation of water vapor is easily seen in the random error in the water vapor mixing ratio data. The loss of sensitivity also affected the maximum range of the usable data, as illustrated by the dramatic decrease in the maximum height seen in the water vapor mixing ratio data (bottom). This degradation, which results in much larger random errors, greatly hinders the analysis of data sets such as the Aerosol IOP (March 2003) and the AIRS Water Vapor Experiment (December 2003). The degradation and its impact on the Aerosol IOP analysis are reported in Ferrare et al. 2005.« less

  5. KSC-2011-1449

    NASA Image and Video Library

    2011-02-15

    CAPE CANAVERAL, Fla. -- At NASA's Kennedy Space Center in Florida, workers receive training atop a mast climber that is attached to launch simulation towers outside the Launch Equipment Test Facility. The training includes attaching carrier plates, water and air systems, and electricity to the climber to simulate working in Kennedy's Vehicle Assembly Building (VAB). Mast climbers can be substituted for fixed service structures currently inside the VAB to provide access to any type of launch vehicle. Since 1977, the facility has supported NASA’s Launch Services, shuttle, International Space Station, and Constellation programs, as well as commercial providers. Last year, the facility underwent a major upgrade to support even more programs, projects and customers. It houses a 6,000-square-foot high bay, cable fabrication and molding shop, pneumatics shop, machine and weld shop and full-scale control room. Outside, the facility features a water flow test loop, vehicle motion simulator and a cryogenic system. Photo credit: NASA/Jim Grossmann

  6. KSC-2011-1446

    NASA Image and Video Library

    2011-02-15

    CAPE CANAVERAL, Fla. -- At NASA's Kennedy Space Center in Florida, workers receive training atop a mast climber that is attached to launch simulation towers outside the Launch Equipment Test Facility. The training includes attaching carrier plates, water and air systems, and electricity to the climber to simulate working in Kennedy's Vehicle Assembly Building (VAB). Mast climbers can be substituted for fixed service structures currently inside the VAB to provide access to any type of launch vehicle. Since 1977, the facility has supported NASA’s Launch Services, shuttle, International Space Station, and Constellation programs, as well as commercial providers. Last year, the facility underwent a major upgrade to support even more programs, projects and customers. It houses a 6,000-square-foot high bay, cable fabrication and molding shop, pneumatics shop, machine and weld shop and full-scale control room. Outside, the facility features a water flow test loop, vehicle motion simulator and a cryogenic system. Photo credit: NASA/Jim Grossmann

  7. KSC-2011-1450

    NASA Image and Video Library

    2011-02-15

    CAPE CANAVERAL, Fla. -- At NASA's Kennedy Space Center in Florida, training takes place atop a mast climber that is attached to launch simulation towers outside the Launch Equipment Test Facility. The training includes attaching carrier plates, water and air systems, and electricity to the climber to simulate working in Kennedy's Vehicle Assembly Building (VAB). Mast climbers can be substituted for fixed service structures currently inside the VAB to provide access to any type of launch vehicle. Since 1977, the facility has supported NASA’s Launch Services, shuttle, International Space Station, and Constellation programs, as well as commercial providers. Last year, the facility underwent a major upgrade to support even more programs, projects and customers. It houses a 6,000-square-foot high bay, cable fabrication and molding shop, pneumatics shop, machine and weld shop and full-scale control room. Outside, the facility features a water flow test loop, vehicle motion simulator and a cryogenic system. Photo credit: NASA/Jim Grossmann

  8. KSC-2011-1448

    NASA Image and Video Library

    2011-02-15

    CAPE CANAVERAL, Fla. -- At NASA's Kennedy Space Center in Florida, workers receive training atop a mast climber that is attached to launch simulation towers outside the Launch Equipment Test Facility. The training includes attaching carrier plates, water and air systems, and electricity to the climber to simulate working in Kennedy's Vehicle Assembly Building (VAB). Mast climbers can be substituted for fixed service structures currently inside the VAB to provide access to any type of launch vehicle. Since 1977, the facility has supported NASA’s Launch Services, shuttle, International Space Station, and Constellation programs, as well as commercial providers. Last year, the facility underwent a major upgrade to support even more programs, projects and customers. It houses a 6,000-square-foot high bay, cable fabrication and molding shop, pneumatics shop, machine and weld shop and full-scale control room. Outside, the facility features a water flow test loop, vehicle motion simulator and a cryogenic system. Photo credit: NASA/Jim Grossmann

  9. KSC-2011-1447

    NASA Image and Video Library

    2011-02-15

    CAPE CANAVERAL, Fla. -- At NASA's Kennedy Space Center in Florida, workers receive training on a mast climber that is attached to launch simulation towers outside the Launch Equipment Test Facility. The training includes attaching carrier plates, water and air systems, and electricity to the climber to simulate working in Kennedy's Vehicle Assembly Building (VAB). Mast climbers can be substituted for fixed service structures currently inside the VAB to provide access to any type of launch vehicle. Since 1977, the facility has supported NASA’s Launch Services, shuttle, International Space Station, and Constellation programs, as well as commercial providers. Last year, the facility underwent a major upgrade to support even more programs, projects and customers. It houses a 6,000-square-foot high bay, cable fabrication and molding shop, pneumatics shop, machine and weld shop and full-scale control room. Outside, the facility features a water flow test loop, vehicle motion simulator and a cryogenic system. Photo credit: NASA/Jim Grossmann

  10. Designing better methane mitigation policies: the challenge of distributed small sources in the natural gas sector

    NASA Astrophysics Data System (ADS)

    Ravikumar, Arvind P.; Brandt, Adam R.

    2017-04-01

    Methane—a short-lived and potent greenhouse gas—presents a unique challenge: it is emitted from a large number of highly distributed and diffuse sources. In this regard, the United States’ Environmental Protection Agency (EPA) has recommended periodic leak detection and repair surveys at oil and gas facilities using optical gas imaging technology. This regulation requires an operator to fix all detected leaks within a set time period. Whether such ‘find-all-fix-all’ policies are effective depends on significant uncertainties in the character of emissions. In this work, we systematically analyze the effect of facility-related and mitigation-related uncertainties on regulation effectiveness. Drawing from multiple publicly-available datasets, we find that: (1) highly-skewed leak-size distributions strongly influence emissions reduction potential; (2) variations in emissions estimates across facilities leads to large variability in mitigation effectiveness; (3) emissions reductions from optical gas imaging-based leak detection programs can range from 15% to over 70%; and (4) while implementation costs are uniformly lower than EPA estimates, benefits from saved gas are highly variable. Combining empirical evidence with model results, we propose four policy options for effective methane mitigation: performance-oriented targets for accelerated emission reductions, flexible policy mechanisms to account for regional variation, technology-agnostic regulations to encourage adoption of the most cost-effective measures, and coordination with other greenhouse gas mitigation policies to reduce unintended spillover effects.

  11. Ownership, competition, and the adoption of new technologies and cost-saving practices in a fixed-price environment.

    PubMed

    Hirth, R A; Chernew, M E; Orzol, S M

    2000-01-01

    Advances in medical technology have been implicated as the primary cause of rising health care expenditures. It is not yet known whether the increasing prevalence of managed care mechanisms, particularly capitation, will change substantially incentives for acquiring and using cost-increasing innovations. We examined the decisions of dialysis units (a set of providers that has faced capitation and real decreases in payment for several decades) with respect to use of cost-increasing technologies that enhance quality of care, cost-cutting practices that reduce quality of care, and amenities desired by patients that are unrelated to quality of care. We found that the dialysis payment system does not appear to have blocked access to a number of new, quality-enhancing technologies that were developed in the 1980s. However, facilities made adjustments along other valuable margins to facilitate adoption of these technologies; use of new technologies varied with numerous facility, regulatory, and case-mix characteristics including ownership, chain membership, size, market competition, and certificate of need programs. Interestingly, the trade-offs made by for-profit and nonprofit facilities when faced with fixed prices appeared quite different. For-profits tended to deliver lower technical quality of care but more amenities, while nonprofits favored technical quality of care over amenities. Our findings may have implications for the response of other types of health care providers to capitation and increasing economic constraints.

  12. STS-37 Mission Specialist (MS) Godwin during simulation in JSC's FB-SMS

    NASA Technical Reports Server (NTRS)

    1991-01-01

    STS-37 Mission Specialist (MS) Linda M. Godwin rehearses some phases of her scheduled duties on the middeck of the fixed-based (FB) shuttle mission simulator (SMS) located in JSC's Mission Simulation and Training Facility Bldg 5. Godwin is inspecting supplies stowed in the middeck lockers during this unsuited simulation.

  13. Lasting Impression

    ERIC Educational Resources Information Center

    Kennedy, Mike

    2006-01-01

    Many schools and universities thought they were getting a good deal when they were building education facilities in the 1950s and 1960s. However, the K-12 and higher-education spaces constructed to accommodate the millions of baby-boomer students no longer look like the quick-fix bargain they did years ago. Low-quality materials and construction,…

  14. Course Scheduling to Find the Minimum Cost Set of Facilities Required.

    ERIC Educational Resources Information Center

    Seccatore, Luis A.

    The problem of determining the quantity of classroom, laboratories and instructors to train sections of students attending numerous distinct courses in a school such as the Fleet Ballistic Missile School is considered. A procedure is developed for determining feasible schedules in order to graduate a fixed number of trainees over time while…

  15. 76 FR 37313 - Turning Point Solar LLC; Notice of Intent To Hold a Public Scoping Meeting and Prepare an...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-27

    ... (MW) ground-mounted solar photovoltaic generating facility in Noble County, Ohio. Turning Point Solar... installation of high- efficiency monocrystalline photovoltaic panels mounted on fixed solar racking equipment... DEPARTMENT OF AGRICULTURE Rural Utilities Service Turning Point Solar LLC; Notice of Intent To...

  16. 30 CFR 250.114 - How must I install and operate electrical equipment?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... structures, and their facilities. (a) You must classify all areas according to API RP 500, Recommended... Class I, Division 1 and Division 2, or API RP 505, Recommended Practice for Classification of Locations... according to API RP 14F, Recommended Practice for Design and Installation of Electrical Systems for Fixed...

  17. 40 CFR 113.4 - Size classes and associated liability limits for fixed onshore oil storage facilities, 1,000...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 21 2010-07-01 2010-07-01 false Size classes and associated liability... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS LIABILITY LIMITS FOR... privity and knowledge of the owner or operator, the following limits of liability are established for...

  18. 47 CFR 74.601 - Classes of TV broadcast auxiliary stations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... or other purposes as authorized in § 74.631. (d) TV translator relay station. A fixed station used... translator, and to other communications facilities that the Commission may authorize or for other purposes as..., TV STL, TV relay, or TV translator relay station and retransmits them on the same frequency. [65 FR...

  19. Cost and logistics for implementing the American College of Surgeons objective structured clinical examination.

    PubMed

    Sudan, Ranjan; Clark, Philip; Henry, Brandon

    2015-01-01

    The American College of Surgeons has developed a reliable and valid OSCE (objective structured clinical examination) to assess the clinical skills of incoming postgraduate year 1 surgery residents, but the cost and logistics of implementation have not been described. Fixed costs included staff time, medical supplies, facility fee, standardized patient (SP) training time, and one OSCE session. Variable costs were incurred for additional OSCE sessions. Costs per resident were calculated and modeled for increasing the number of test takers. American College of Surgeons OSCE materials and examination facilities were free. Fixed costs included training 11 SPs for 4 hours ($1,540), moulage and simulation material ($469), and administrative effort for 44 hours ($2,200). Variable cost for each session was $1,540 (SP time). Total cost for the first session was $6,649 ($664/resident), decreased to $324/resident for 3 sessions, and projected to further decline to $239/resident for 6 sessions. The cost decreased as the number of residents tested increased. To manage costs, testing more trainees by regional collaboration is recommended. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. Effects of State Minimum Staffing Standards on Nursing Home Staffing and Quality of Care

    PubMed Central

    Park, Jeongyoung; Stearns, Sally C

    2009-01-01

    Objective To investigate the impact of state minimum staffing standards on the level of staffing and quality of nursing home care. Data Sources Online Survey and Certification Reporting System (OSCAR) merged with the Area Resource File from 1998 through 2001. Study Design Between 1998 and 2001, 16 states implemented or expanded staffing standards in excess of federal requirements, creating a natural experiment in comparison with facilities in states without new standards. Difference-in-differences models using facility fixed effects were estimated to determine the effect of state standards. Data Collection/Extraction Methods OSCAR data were linked to the data on market conditions and state policies. A total of 55,248 facility-year observations from 15,217 freestanding facilities were analyzed. Principal Findings Increased standards resulted in small staffing increases for facilities with staffing initially below or close to new standards. Yet the standards were associated with reductions in restraint use and the number of total deficiencies at all types of facilities. Conclusions Mandated staffing standards affect only low-staff facilities facing potential for penalties, and effects are small. Selected facility-level outcomes may show improvement at all facilities due to a general response to increased standards or to other quality initiatives implemented at the same time as staffing standards. PMID:18823448

  1. ARM Mentor Selection Process

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sisterson, D. L.

    2015-10-01

    The Atmospheric Radiation Measurement (ARM) Program was created in 1989 with funding from the U.S. Department of Energy (DOE) to develop several highly instrumented ground stations to study cloud formation processes and their influence on radiative transfer. In 2003, the ARM Program became a national scientific user facility, known as the ARM Climate Research Facility. This scientific infrastructure provides for fixed sites, mobile facilities, an aerial facility, and a data archive available for use by scientists worldwide through the ARM Climate Research Facility—a scientific user facility. The ARM Climate Research Facility currently operates more than 300 instrument systems that providemore » ground-based observations of the atmospheric column. To keep ARM at the forefront of climate observations, the ARM infrastructure depends heavily on instrument scientists and engineers, also known as lead mentors. Lead mentors must have an excellent understanding of in situ and remote-sensing instrumentation theory and operation and have comprehensive knowledge of critical scale-dependent atmospheric processes. They must also possess the technical and analytical skills to develop new data retrievals that provide innovative approaches for creating research-quality data sets. The ARM Climate Research Facility is seeking the best overall qualified candidate who can fulfill lead mentor requirements in a timely manner.« less

  2. Scaling laws between population and facility densities.

    PubMed

    Um, Jaegon; Son, Seung-Woo; Lee, Sung-Ik; Jeong, Hawoong; Kim, Beom Jun

    2009-08-25

    When a new facility like a grocery store, a school, or a fire station is planned, its location should ideally be determined by the necessities of people who live nearby. Empirically, it has been found that there exists a positive correlation between facility and population densities. In the present work, we investigate the ideal relation between the population and the facility densities within the framework of an economic mechanism governing microdynamics. In previous studies based on the global optimization of facility positions in minimizing the overall travel distance between people and facilities, it was shown that the density of facility D and that of population rho should follow a simple power law D approximately rho(2/3). In our empirical analysis, on the other hand, the power-law exponent alpha in D approximately rho(alpha) is not a fixed value but spreads in a broad range depending on facility types. To explain this discrepancy in alpha, we propose a model based on economic mechanisms that mimic the competitive balance between the profit of the facilities and the social opportunity cost for populations. Through our simple, microscopically driven model, we show that commercial facilities driven by the profit of the facilities have alpha = 1, whereas public facilities driven by the social opportunity cost have alpha = 2/3. We simulate this model to find the optimal positions of facilities on a real U.S. map and show that the results are consistent with the empirical data.

  3. KSC-2009-6449

    NASA Image and Video Library

    2009-11-19

    CAPE CANAVERAL, Fla. – NASA's first large-scale solar power generation facility is unveiled at NASA's Kennedy Space Center in Florida. Representatives from NASA, Florida Power & Light Company, or FPL, and SunPower Corporation formally commissioned the one-megawatt facility and announced plans to pursue a new research, development and demonstration project at Kennedy to advance America's use of renewable energy. The facility is the first element of a major renewable energy project currently under construction at Kennedy. The completed system features a fixed-tilt, ground-mounted solar power system designed and built by SunPower, along with SunPower solar panels. A 10-megawatt solar farm, which SunPower is building on nearby Kennedy property, will supply power to FPL's customers when it is completed in April 2010. Photo credit: NASA/Jim Grossmann

  4. KSC-2009-6457

    NASA Image and Video Library

    2009-11-19

    CAPE CANAVERAL, Fla. – NASA's first large-scale solar power generation facility is ready for operation at NASA's Kennedy Space Center in Florida. Representatives from NASA, Florida Power & Light Company, or FPL, and SunPower Corporation formally commissioned the one-megawatt facility and announced plans to pursue a new research, development and demonstration project at Kennedy to advance America's use of renewable energy. The facility is the first element of a major renewable energy project currently under construction at Kennedy. The completed system features a fixed-tilt, ground-mounted solar power system designed and built by SunPower, along with SunPower solar panels. A 10-megawatt solar farm, which SunPower is building on nearby Kennedy property, will supply power to FPL's customers when it is completed in April 2010. Photo credit: NASA/Jim Grossmann

  5. KSC-2009-6450

    NASA Image and Video Library

    2009-11-19

    CAPE CANAVERAL, Fla. – NASA's first large-scale solar power generation facility opens at NASA's Kennedy Space Center in Florida. Representatives from NASA, Florida Power & Light Company, or FPL, and SunPower Corporation formally commissioned the one-megawatt facility and announced plans to pursue a new research, development and demonstration project at Kennedy to advance America's use of renewable energy. The facility is the first element of a major renewable energy project currently under construction at Kennedy. The completed system features a fixed-tilt, ground-mounted solar power system designed and built by SunPower, along with SunPower solar panels. A 10-megawatt solar farm, which SunPower is building on nearby Kennedy property, will supply power to FPL's customers when it is completed in April 2010. Photo credit: NASA/Jim Grossmann

  6. Nursing home performance under case-mix reimbursement: responding to heavy-care incentives and market changes.

    PubMed Central

    Davis, M A; Freeman, J W; Kirby, E C

    1998-01-01

    OBJECTIVE: To examine the effect of case mix-adjusted reimbursement policy and market factors on nursing home performance. DATA SOURCES AND STUDY SETTING: Data from Medicaid certification inspection surveys, Medicaid cost reports, and the Kentucky State Center for Health Statistics for the years 1989 and 1991, to examine changes in nursing home performance stemming from the adoption of case mix-adjusted reimbursement in 1990. STUDY DESIGN: In addition to cross-sectional regressions, a first-difference approach to fixed-effects regression analyses was employed to control for facility differences that were essentially fixed during the survey years and to estimate the effects of time-varying predictors on changes in facility expenditures, efficiency, and profitability. PRINCIPAL FINDINGS: Facilities that increased the proportion of Medicaid residents and eliminated excess capacity experienced higher profitability gains during the beginning phase of case-mix reimbursement. Having a heavy-care resident population was positively related to expenditures prior to reimbursement reform, and it was negatively related to expenditures after the case-mix reimbursement policy was introduced. While facility-level changes in case mix had no reliable influence on costs or profits, nursing homes showing an increased prevalence of poor-quality nursing practices exhibited increases in efficiency and profitability. At the market level, reductions in excess or empty nursing home beds were accompanied by a significant growth in home health services. Moreover, nursing homes located in markets with expanding home health services exhibited higher increases in costs per case-mix unit. CONCLUSIONS: Characteristics of the reimbursement system appear to reward a cost minimization orientation with potentially detrimental effects on quality of care. These effects, exacerbated by a supply-constrained market, may be mitigated by policies that encourage the expansion of home health service availability. PMID:9776938

  7. Nursing home performance under case-mix reimbursement: responding to heavy-care incentives and market changes.

    PubMed

    Davis, M A; Freeman, J W; Kirby, E C

    1998-10-01

    To examine the effect of case mix-adjusted reimbursement policy and market factors on nursing home performance. Data from Medicaid certification inspection surveys, Medicaid cost reports, and the Kentucky State Center for Health Statistics for the years 1989 and 1991, to examine changes in nursing home performance stemming from the adoption of case mix-adjusted reimbursement in 1990. In addition to cross-sectional regressions, a first-difference approach to fixed-effects regression analyses was employed to control for facility differences that were essentially fixed during the survey years and to estimate the effects of time-varying predictors on changes in facility expenditures, efficiency, and profitability. Facilities that increased the proportion of Medicaid residents and eliminated excess capacity experienced higher profitability gains during the beginning phase of case-mix reimbursement. Having a heavy-care resident population was positively related to expenditures prior to reimbursement reform, and it was negatively related to expenditures after the case-mix reimbursement policy was introduced. While facility-level changes in case mix had no reliable influence on costs or profits, nursing homes showing an increased prevalence of poor-quality nursing practices exhibited increases in efficiency and profitability. At the market level, reductions in excess or empty nursing home beds were accompanied by a significant growth in home health services. Moreover, nursing homes located in markets with expanding home health services exhibited higher increases in costs per case-mix unit. Characteristics of the reimbursement system appear to reward a cost minimization orientation with potentially detrimental effects on quality of care. These effects, exacerbated by a supply-constrained market, may be mitigated by policies that encourage the expansion of home health service availability.

  8. [Development of fixed-base full task space flight training simulator].

    PubMed

    Xue, Liang; Chen, Shan-quang; Chang, Tian-chun; Yang, Hong; Chao, Jian-gang; Li, Zhi-peng

    2003-01-01

    Fixed-base full task flight training simulator is a very critical and important integrated training facility. It is mostly used in training of integrated skills and tasks, such as running the flight program of manned space flight, dealing with faults, operating and controlling spacecraft flight, communicating information between spacecraft and ground. This simulator was made up of several subentries including spacecraft simulation, simulating cabin, sight image, acoustics, main controlling computer, instructor and assistant support. It has implemented many simulation functions, such as spacecraft environment, spacecraft movement, communicating information between spacecraft and ground, typical faults, manual control and operating training, training control, training monitor, training database management, training data recording, system detecting and so on.

  9. Cryogenic Fluid Film Bearing Tester Development Study

    NASA Technical Reports Server (NTRS)

    Scharrer, Joseph K. (Editor); Murphy, Brian T.; Hawkins, Lawrence A.

    1993-01-01

    Conceptual designs were developed for the determination of rotordynamic coefficients of cryogenic fluid film bearings. The designs encompassed the use of magnetic and conventional excitation sources as well as the use of magnetic bearings as support bearings. Test article configurations reviewed included overhung, floating housing, and fixed housing. Uncertainty and forced response analyses were performed to assess quality of data and suitability of each for testing a variety of fluid film bearing designs. Development cost and schedule estimates were developed for each design. Facility requirements were reviewed and compared with existing MSFC capability. The recommended configuration consisted of a fixed test article housing centrally located between two magnetic bearings. The magnetic bearings would also serve as the excitation source.

  10. STS-37 Mission Specialist (MS) Ross during simulation in JSC's FB-SMS

    NASA Technical Reports Server (NTRS)

    1991-01-01

    STS-37 Mission Specialist (MS) Jerry L. Ross 'borrows' the pilots station to rehearse some of his scheduled duties for his upcoming mission. He is on the flight deck of the fixed-based (FB) shuttle mission simulator (SMS) during this unsuited simulation. The SMS is part of JSC's Mission Simulation and Training Facility Bldg 5.

  11. STS-26 simulation activities in JSC Mission Control Center (MCC)

    NASA Technical Reports Server (NTRS)

    1987-01-01

    In JSC Mission Control Center (MCC) Bldg 30 Flight Control Room (FCR), astronauts John O. Creighton (right) and L. Blaine Hammond review their notes while serving as spacecraft communicators (CAPCOMs) for STS-26 simulations in progress between MCC and JSC Mission Simulation and Training Facility Bldg 5 fixed-base (FB) shuttle mission simulator (SMS).

  12. STS-26 simulation activities in JSC Mission Control Center (MCC)

    NASA Technical Reports Server (NTRS)

    1987-01-01

    In JSC Mission Control Center (MCC) Bldg 30 Flight Control Room (FCR), flight directors (FDs) Lee Briscoe (left) and Charles W. Shaw, seated at FD console, view front visual display monitors during STS-26 simulations in progress between MCC and JSC Mission Simulation and Training Facility Bldg 5 fixed-base (FB) shuttle mission simulator (SMS).

  13. Fixed Equipment in the Energy Systems Integration Facility | Energy Systems

    Science.gov Websites

    dynamic simulation of future energy systems. Photo of a robot used to test hydrogen coupling hardware. At test chambers (rated up to 60°C) for testing HVAC systems under simulated loading conditions Two bench performance Test stand for measuring performance of receiver tubes for concentrating solar power applications

  14. 10 CFR 73.46 - Fixed site physical protection systems, subsystems, components, and procedures.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... barrier in the event of its penetration. If parking facilities are provided for employees or visitors... bullet resisting walls, doors, ceiling, floor, and windows. (ii) When the licensee has cause to suspect..., and name of the individual to be visited in a log. The licensee shall retain each log as a record for...

  15. 10 CFR 73.46 - Fixed site physical protection systems, subsystems, components, and procedures.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... barrier in the event of its penetration. If parking facilities are provided for employees or visitors... bullet resisting walls, doors, ceiling, floor, and windows. (ii) When the licensee has cause to suspect..., and name of the individual to be visited in a log. The licensee shall retain each log as a record for...

  16. 30 CFR 203.76 - When might MMS withdraw or reduce the approved size of my relief?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... your post-production development report (§ 203.70). Development costs are those expenditures defined in... application (e.g., change from a fixed platform to floating production system, or from an independent development and production system to one with subsea wells tied back to a host production facility, etc.). (b...

  17. Voluntary Medical Male Circumcision Scale-Up in Nyanza, Kenya: Evaluating Technical Efficiency and Productivity of Service Delivery

    PubMed Central

    Omondi Aduda, Dickens S.; Ouma, Collins; Onyango, Rosebella; Onyango, Mathews; Bertrand, Jane

    2015-01-01

    Background Voluntary medical male circumcision (VMMC) service delivery is complex and resource-intensive. In Kenya’s context there is still paucity of information on resource use vis-à-vis outputs as programs scale up. Knowledge of technical efficiency, productivity and potential sources of constraints is desirable to improve decision-making. Objective To evaluate technical efficiency and productivity of VMMC service delivery in Nyanza in 2011/2012 using data envelopment analysis. Design Comparative process evaluation of facilities providing VMMC in Nyanza in 2011/2012 using output orientated data envelopment analysis. Results Twenty one facilities were evaluated. Only 1 of 7 variables considered (total elapsed operation time) significantly improved from 32.8 minutes (SD 8.8) in 2011 to 30 minutes (SD 6.6) in 2012 (95%CI = 0.0350–5.2488; p = 0.047). Mean scale technical efficiency significantly improved from 91% (SD 19.8) in 2011 to 99% (SD 4.0) in 2012 particularly among outreach compared to fixed service delivery facilities (CI -31.47959–4.698508; p = 0.005). Increase in mean VRS technical efficiency from 84% (SD 25.3) in 2011 and 89% (SD 25.1) in 2012 was not statistically significant. Benchmark facilities were #119 and #125 in 2011 and #103 in 2012. Malmquist Productivity Index (MPI) at fixed facilities declined by 2.5% but gained by 4.9% at outreach ones by 2012. Total factor productivity improved by 83% (p = 0.032) in 2012, largely due to progress in technological efficiency by 79% (p = 0.008). Conclusions Significant improvement in scale technical efficiency among outreach facilities in 2012 was attributable to accelerated activities. However, ongoing pure technical inefficiency requires concerted attention. Technological progress was the key driver of service productivity growth in Nyanza. Incorporating service-quality dimensions and using stepwise-multiple criteria in performance evaluation enhances comprehensiveness and validity. These findings highlight site-level resource use and sources of variations in VMMC service productivity, which are important for program planning. PMID:25706119

  18. Managing Waste Inventory and License Limits at the Perma-Fix Northwest Facility to Meet CH2M Hill Plateau Remediation Company (CHPRC) American Recovery and Reinvestment Act (ARRA) Deliverables - 12335

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moak, Don J.; Grondin, Richard L.; Triner, Glen C.

    CH2M Hill Plateau Remediation Company (CHRPC) is a prime contractor to the U.S. Department of Energy (DOE) focused on the largest ongoing environmental remediation project in the world at the DOE Hanford Site Central Plateau, i.e. the DOE Hanford Plateau Remediation Contract. The East Tennessee Materials and Energy Corporation (M and EC); a wholly owned subsidiary of Perma-Fix Environmental Services, Inc. (PESI), is a small business team member to CHPRC. Our scope includes project management; operation and maintenance of on-site storage, repackaging, treatment, and disposal facilities; and on-site waste management including waste receipt from generators and delivery to on-site andmore » off-site treatment, storage, and disposal facilities. As part of this scope, M and EC staffs the centralized Waste Support Services organization responsible for all waste characterization and acceptance required to support CHPRC and waste generators across the Hanford Site. At the time of the CHPRC contract award (August 2008) slightly more than 9,000 cubic meters (m{sup 3}) of legacy waste was defined as 'no-path-forward waste'. A significant portion of this waste (7,650 m{sup 3}) comprised wastes with up to 50 grams of special nuclear materials (SNM) in oversized packages recovered during retrieval operations and large glove boxes removed from the Plutonium Finishing Plant (PFP). Through a collaborative effort between the DOE, CHPRC, and Perma-Fix Environmental Services, Inc. (PESI), pathways for these problematic wastes were developed that took advantage of commercial treatment capabilities at a nearby vendor facility, Perma-Fix Northwest (PFNW). In the spring of 2009, CHPRC initiated a pilot program under which they began shipping large package, low gram suspect TRU (<15 g SNM per container), and large package contact and remote handled MLLW to the off-site PFNW facility for treatment. PFNW is restricted by the SNM limits set for the total quantity of SNM allowed at the facility in accordance with the facility's radioactive materials license(s) (RML). While both CHPRC and PFNW maintain waste databases to track all waste movements, it became evident early in the process that a tool was needed that married the two systems to better track SNM inventories and sequence waste from the point of generation, through the PFNW facility, and back to the Hanford site for final disposition. This tool, known as the Treatment Integration and Planning Tool (TIPT), has become a robust planning tool that provides real-time data to support compliant and efficient waste generation, transportation, treatment, and disposition. TIPT is developing into the next generation tool that will change the way in which legacy wastes, retrieval wastes and decontamination and decommissioning operations are conducted on the Plateau Remediation Contract (PRC). The real value of the TIPT is its predictive capability. It allows the W and FMP to map out optimal windows for processing waste through the PFNW facility, or through any process that is in some way resource limited. It allows project managers to identify and focus on problem areas before shipments are affected. It has been modified for use in broader applications to predict turnaround times and identify windows of opportunity for processing higher gram wastes through PFNW and to allow waste generators, site-wide, to accurately predict scope, cost, and schedule for waste generation to optimize processing and eliminate storage, double handling, and related costs and unnecessary safety risks. The TIPT addresses the years old problem of how to effectively predict not only what needs to be done, but when. 'When' is the key planning parameter that has been ignored by the generator and processor for many years, but has proven to be the most important parameter for both parties. While further refinement is a natural part of any development process, the current improvements on the TIPT have shown that prediction is a powerful consideration. Even in lean times expected for the foreseeable future, the improved TIPT continues to play a central role in managing our way through those times to assure facilities remain viable and available. It is recommended that other major remediation projects and waste processing facilities incorporate a tool such as TIPT to improve customer-commercial supplier communications and better optimization of resources. (authors)« less

  19. Operational Experience of an Open-Access, Subscription-Based Mass Spectrometry and Proteomics Facility.

    PubMed

    Williamson, Nicholas A

    2018-03-01

    This paper discusses the successful adoption of a subscription-based, open-access model of service delivery for a mass spectrometry and proteomics facility. In 2009, the Mass Spectrometry and Proteomics Facility at the University of Melbourne (Australia) moved away from the standard fee for service model of service provision. Instead, the facility adopted a subscription- or membership-based, open-access model of service delivery. For a low fixed yearly cost, users could directly operate the instrumentation but, more importantly, there were no limits on usage other than the necessity to share available instrument time with all other users. All necessary training from platform staff and many of the base reagents were also provided as part of the membership cost. These changes proved to be very successful in terms of financial outcomes for the facility, instrument access and usage, and overall research output. This article describes the systems put in place as well as the overall successes and challenges associated with the operation of a mass spectrometry/proteomics core in this manner. Graphical abstract ᅟ.

  20. Operational Experience of an Open-Access, Subscription-Based Mass Spectrometry and Proteomics Facility

    NASA Astrophysics Data System (ADS)

    Williamson, Nicholas A.

    2018-03-01

    This paper discusses the successful adoption of a subscription-based, open-access model of service delivery for a mass spectrometry and proteomics facility. In 2009, the Mass Spectrometry and Proteomics Facility at the University of Melbourne (Australia) moved away from the standard fee for service model of service provision. Instead, the facility adopted a subscription- or membership-based, open-access model of service delivery. For a low fixed yearly cost, users could directly operate the instrumentation but, more importantly, there were no limits on usage other than the necessity to share available instrument time with all other users. All necessary training from platform staff and many of the base reagents were also provided as part of the membership cost. These changes proved to be very successful in terms of financial outcomes for the facility, instrument access and usage, and overall research output. This article describes the systems put in place as well as the overall successes and challenges associated with the operation of a mass spectrometry/proteomics core in this manner. [Figure not available: see fulltext.

  1. The NASA Lewis integrated propulsion and flight control simulator

    NASA Technical Reports Server (NTRS)

    Bright, Michelle M.; Simon, Donald L.

    1991-01-01

    A new flight simulation facility has been developed at NASA Lewis to allow integrated propulsion-control and flight-control algorithm development and evaluation in real time. As a preliminary check of the simulator facility and the correct integration of its components, the control design and physics models for an STOVL fighter aircraft model have been demonstrated, with their associated system integration and architecture, pilot vehicle interfaces, and display symbology. The results show that this fixed-based flight simulator can provide real-time feedback and display of both airframe and propulsion variables for validation of integrated systems and testing of control design methodologies and cockpit mechanizations.

  2. Fundamentals of SCADA and automated meter reading

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kwok, A.

    1992-02-01

    This paper discusses SCADA systems allow users to control and acquire data from remote facilities such as compressors, pressure-regulating stations, control valves and measurement stations. In general, a SCADA system performs functions in sequential control, continuous control, supervisory setpoint control and data acquisitions. AMR systems allow users to obtain up-to-date information on their gas demand. When AMR was in its infancy, equipment was designed only to read and record gas consumption values. The basic function of an early AMR system was to read gas volume at a fixed interval and record the data in its memory until it communicated withmore » a central receiving facility.« less

  3. Engineering Support of Microgravity Life Science Research: Development of an Avian Development Facility

    NASA Technical Reports Server (NTRS)

    Vellinger, J.; Deuser, M.; Hullinger, R.

    1995-01-01

    The Avian Development Facility (ADF) is designed to provide a 'window' for the study of embryogenesis in space. It allows researchers to determine and then to mitigate or nullify the forces of altered gravity upon embryos when leaving and re-entering the Earth's gravity. The ADF design will allow investigations to begin their incubation after their experiments have achieved orbit, and shut down the experiment and fix specimens before leaving orbit. In effect, the ADF makes every attempt to minimize launch and re-entry effects in order to isolate and preserve the effects of the experimental variable(s) of the space environment.

  4. Wing Twist Measurements at the National Transonic Facility

    NASA Technical Reports Server (NTRS)

    Burner, Alpheus W.; Wahls, Richard A.; Goad, William K.

    1996-01-01

    A technique for measuring wing twist currently in use at the National Transonic Facility is described. The technique is based upon a single camera photogrammetric determination of two dimensional coordinates with a fixed (and known) third dimensional coordinate. The wing twist is found from a conformal transformation between wind-on and wind-off 2-D coordinates in the plane of rotation. The advantages and limitations of the technique as well as the rationale for selection of this particular technique are discussed. Examples are presented to illustrate run-to-run and test-to-test repeatability of the technique in air mode. Examples of wing twist in cryogenic nitrogen mode are also presented.

  5. KSC-2009-6452

    NASA Image and Video Library

    2009-11-19

    CAPE CANAVERAL, Fla. – NASA Kennedy Space Center Director Bob Cabana addresses the audience on hand for the unveiling of NASA's first large-scale solar power generation facility at Kennedy in Florida. Representatives from NASA, Florida Power & Light Company, or FPL, and SunPower Corporation formally commissioned the one-megawatt facility and announced plans to pursue a new research, development and demonstration project at Kennedy to advance America's use of renewable energy. The facility is the first element of a major renewable energy project currently under construction at Kennedy. The completed system features a fixed-tilt, ground-mounted solar power system designed and built by SunPower, along with SunPower solar panels. A 10-megawatt solar farm, which SunPower is building on nearby Kennedy property, will supply power to FPL's customers when it is completed in April 2010. Photo credit: NASA/Jim Grossmann

  6. Reliability of High-Temperature Fixed-Point Installations over 8 Years

    NASA Astrophysics Data System (ADS)

    Elliott, C. J.; Ford, T.; Ongrai, O.; Pearce, J. V.

    2017-12-01

    At NPL, high-temperature metal-carbon eutectic fixed points have been set up for thermocouple calibration purposes since 2006, for realising reference temperatures above the highest point specified in the International Temperature Scale of 1990 for contact thermometer calibrations. Additionally, cells of the same design have been provided by NPL to other national measurement institutes (NMIs) and calibration laboratories over this period, creating traceable and ISO 17025 accredited facilities around the world for calibrating noble metal thermocouples at 1324 {°}C (Co-C) and 1492 {°}C (Pd-C). This paper shows collections of thermocouple calibration results obtained during use of the high-temperature fixed-point cells at NPL and, as further examples, the use of cells installed at CCPI Europe (UK) and NIMT (Thailand). The lifetime of the cells can now be shown to be in excess of 7 years, whether used on a weekly or monthly basis, and whether used in an NMI or industrial calibration laboratory.

  7. Mechanisms of and facility types involved in hazardous materials incidents.

    PubMed Central

    Kales, S N; Polyhronopoulos, G N; Castro, M J; Goldman, R H; Christiani, D C

    1997-01-01

    The purpose of this study was to systematically investigate hazardous materials (hazmat) releases and determine the mechanisms of these accidents, and the industries/activities and chemicals involved. We analyzed responses by Massachusetts' six district hazmat teams from their inception through May 1996. Information from incident reports was extracted onto standard coding sheets. The majority of hazardous materials incidents were caused by spills, leaks, or escapes of hazardous materials (76%) and occurred at fixed facilities (80%). Transportation-related accidents accounted for 20% of incidents. Eleven percent of hazardous materials incidents were at schools or health care facilities. Petroleum-derived fuels were involved in over half of transportation-related accidents, and these accounted for the majority of petroleum fuel releases. Chlorine derivatives were involved in 18% of all accidents and were associated with a wide variety of facility types and activities. In conclusion, systematic study of hazardous materials incidents allows the identification of preventable causes of these incidents. PMID:9300926

  8. Classification of Reactor Facility Operational State Using SPRT Methods with Radiation Sensor Networks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ramirez Aviles, Camila A.; Rao, Nageswara S.

    We consider the problem of inferring the operational state of a reactor facility by using measurements from a radiation sensor network, which is deployed around the facility’s ventilation stack. The radiation emissions from the stack decay with distance, and the corresponding measurements are inherently random with parameters determined by radiation intensity levels at the sensor locations. We fuse measurements from network sensors to estimate the intensity at the stack, and use this estimate in a one-sided Sequential Probability Ratio Test (SPRT) to infer the on/off state of the reactor facility. We demonstrate the superior performance of this method over conventionalmore » majority vote fusers and individual sensors using (i) test measurements from a network of NaI sensors, and (ii) emulated measurements using radioactive effluents collected at a reactor facility stack. We analytically quantify the performance improvements of individual sensors and their networks with adaptive thresholds over those with fixed ones, by using the packing number of the radiation intensity space.« less

  9. Fix It and They Might Stay: School Facility Quality and Teacher Retention in Washington, D.C.

    ERIC Educational Resources Information Center

    Buckley, Jack; Schneider, Mark; Shang, Yi

    2005-01-01

    The attrition of both new and experienced teachers is a challenge for schools and school administrators throughout the United States, particularly in large urban districts. Because of the importance of this issue, there is a large empirical literature that investigates why teachers quit and how they might be induced to stay. Here we build upon…

  10. STS-31 crewmembers review checklist with instructor on JSC's FB-SMS middeck

    NASA Technical Reports Server (NTRS)

    1988-01-01

    STS-31 Discovery, Orbiter Vehicle (OV) 103, Mission Specialist (MS) Bruce McCandless II (left) and Pilot Charles F. Bolden (right) discuss procedures with a training instructor on the middeck of JSC's fixed-based (FB) Shuttle Mission Simulator (SMS). The three are pointing to a checklist during this training simulation in the Mission Simulation and Training Facility Bldg 5.

  11. Proceedings of the 1982 DPF summer study on elementary particle physics and future facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Donaldson, R.; Gustafson, R.; Paige, F.

    1982-01-01

    This book presents the papers given at a conference on high energy physics. Topics considered at the conference included synchrotron radiation, testing the standard model, beyond the standard model, exploring the limits of accelerator technology, novel detector ideas, lepton-lepton colliders, lepton-hadron colliders, hadron-hadron colliders, fixed-target accelerators, non-accelerator physics, and sociology.

  12. Reducing the period of data collection for intake and gain to improve response to selection for feed efficiency in beef cattle

    USDA-ARS?s Scientific Manuscript database

    Shortening the period of recording individual feed intake may improve selection response for feed efficiency by increasing the number of cattle that can be recorded given facilities of fixed capacity. Individual DMI and ADG records of 3,462 steers and 2,869 heifers over the entire intake recording p...

  13. SRF test facility for the superconducting LINAC ``RAON'' — RRR property and e-beam welding

    NASA Astrophysics Data System (ADS)

    Jung, Yoochul; Hyun, Myungook; Joo, Jongdae; Joung, Mijoung

    2015-02-01

    Equipment, such as a vacuum furnace, high pressure rinse (HPR), eddy current test (ECT) and buffered chemical polishing (BCP), are installed in the superconducting radio frequency (SRF) test facility. Three different sizes of cryostats (diameters of 600 mm for a quarter wave resonator (QWR), 900 mm for a half wave resonator (HWR), and 1200 mm for single spoke resonator 1&2 (SSR 1&2)) for vertical RF tests are installed for testing cavities. We confirmed that as-received niobium sheets (ASTM B393, RRR300) good electrical properties because they showed average residual resistance ratio (RRR) values higher than 300. However, serious RRR degradation occurred after joining two pieces of Nb by e-beam welding because the average RRR values of the samples were ˜179, which was only ˜60% of as-received RRR value. From various e-beam welding experiments in which the welding current and a speed at a fixed welding voltage were changed, we confirmed that good welding results were obtained at a 53 mA welding current and a 20-mm/s welding speed at a fixed welding voltage of 150 kV.

  14. Rational's experience using Ada for very large systems

    NASA Technical Reports Server (NTRS)

    Archer, James E., Jr.; Devlin, Michael T.

    1986-01-01

    The experience using the Rational Environment has confirmed the advantages forseen when the project was started. Interactive syntatic and semantic information makes a tremendous difference in the ease of constructing programs and making changes to them. The ability to follow semantic references makes it easier to understand exisiting programs and the impact of changes. The integrated debugger makes it much easier to find bugs and test fixes quickly. Taken together, these facilites have helped greatly in reducing the impact of ongoing maintenance of the ability to produce a new code. Similar improvements are anticipated as the same level of integration and interactivity are achieved for configuration management and version control. The environment has also proven useful in introducing personnel to the project and existing personnel to new parts of the system. Personnel benefit from the assistance with syntax and semantics; everyone benefits from the ability to traverse and understand the structure of unfamiliar software. It is often possible for someone completely unfamiliar with a body of code to use these facilities, to understand it well enough to successfully with a body of code to use these facilities to understand it well enough to successfully diagnose and fix bugs in a matter of minutes.

  15. Test results and description of a 1-kW free-piston Stirling engine with a dashpot load

    NASA Technical Reports Server (NTRS)

    Schreiber, J.

    1983-01-01

    A 1 kW (1.33 hp) single cylinder free piston Stirling engine was installed in the test facilities at the Lewis laboratory. The engine was designed specifically for research of the dynamics of its operation. A more complete description of the engine and its instrumentation is provided in a prior NASA paper TM-82999 by J. G. Schreiber. Initial tests at Lewis showed the power level and efficiency of the engine to be below design level. Tests were performed to help determine the specific problems in the engine causing the below design level performance. Modifications to engine hardware and to the facility where performed in an effort to bring the power output and efficiency to their design values. As finally configured the engine generated more than 1250 watts of output power at an engine efficiency greater than 32 percent. This report presents the tests performed to help determine the specific problems, the results if the problem was eliminated, the fix performed to the hardware, and the test results after the engine was tested. In cases where the fix did not cause the anticipated effects, a possible explanation is given.

  16. Channel simulation to facilitate mobile-satellite communications research

    NASA Technical Reports Server (NTRS)

    Davarian, Faramaz

    1987-01-01

    The mobile-satellite-service channel simulator, which is a facility for an end-to-end hardware simulation of mobile satellite communications links is discussed. Propagation effects, Doppler, interference, band limiting, satellite nonlinearity, and thermal noise have been incorporated into the simulator. The propagation environment in which the simulator needs to operate and the architecture of the simulator are described. The simulator is composed of: a mobile/fixed transmitter, interference transmitters, a propagation path simulator, a spacecraft, and a fixed/mobile receiver. Data from application experiments conducted with the channel simulator are presented; the noise converison technique to evaluate interference effects, the error floor phenomenon of digital multipath fading links, and the fade margin associated with a noncoherent receiver are examined. Diagrams of the simulator are provided.

  17. Walkthrough screening evaluation field guide. Natural phenomena hazards at Department of Energy facilities: Revision 2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eder, S.J.; Eli, M.W.; Salmon, M.W.

    1993-11-01

    The US Department of Energy (DOE) has a large inventory of existing facilities. Many of these facilities were not designed and constructed to current natural phenomena hazard (NPH) criteria. The NPH events include earthquakes, extreme winds and tornadoes, and floods. DOE Order 5480.28 establishes policy and requirements for NPH mitigation for DOE facilities. DOE is conducting a multiyear project to develop evaluation guidelines for assessing the condition and determining the need for upgrades at DOE facilities. One element of the NPH evaluation guidelines` development involves the existing systems and components at DOE facilities. This effort is described in detail inmore » a cited reference. In the interim period prior to availability of the final guidelines, DOE facilities are encouraged to implement an NPH walk through screening evaluation process by which systems and components that need attention can be rapidly identified. Guidelines for conducting the walk through screening evaluations are contained herein. The result of the NPH walk through screening evaluation should be a prioritized list of systems and components that need further action. Simple and inexpensive fixes for items identified in the walk through as marginal or inadequate should be implemented without further study. By implementing an NPH walk through screening evaluation, DOE facilities may realize significant reduction in risk from NPH in the short term.« less

  18. STS-37 crewmembers train in JSC's FB shuttle mission simulator (SMS)

    NASA Technical Reports Server (NTRS)

    1991-01-01

    STS-37 Commander Steven R. Nagel (left) and Mission Specialist (MS) Jerry L. Ross rehearse some of their scheduled duties on the flight deck of JSC's fixed-based (FB) shuttle mission simulator (SMS) located in the Mission Simulation and Training Facility Bldg 5. During the unsuited simulation, Nagel reviews checklist while seated at the commanders station as Ross looks on from the pilots station.

  19. STS-44 Atlantis, OV-104, Pilot Henricks in FB-SMS training at JSC

    NASA Technical Reports Server (NTRS)

    1991-01-01

    STS-44 Atlantis, Orbiter Vehicle (OV) 104, Pilot Terence T. Henricks, seated at the pilots station on the forward flight deck, reviews checklists before a flight simulation in the Fixed Base (FB) Shuttle Mission Simulator (SMS) located in JSC's Mission Simulation and Training Facility Bldg 5. Surrounding Henricks are the seat back, the overhead panels, forward panels, and forward windows.

  20. STS-31 Pilot Bolden with beverages on the FB-SMS middeck during JSC training

    NASA Technical Reports Server (NTRS)

    1988-01-01

    STS-31 Pilot Charles F. Bolden holds three beverage containers while in front of the galley on the middeck of the fixed based (FB) shuttle mission simulator (SMS) during a training simulation at JSC's Mission Simulation and Training Facility Bldg 5. From the middeck, Bolden, wearing lightweight headset, simulates a communications link with ground controllers and fellow crewmembers.

  1. Control of free-flying space robot manipulator systems

    NASA Technical Reports Server (NTRS)

    Cannon, Robert H., Jr.

    1977-01-01

    To accelerate the development of multi-armed, free-flying satellite manipulators, a fixed-base cooperative manipulation facility is being developed. The work performed on multiple arm cooperation on a free-flying robot is summarized. Research is also summarized on global navigation and control of free-flying space robots. The Locomotion Enhancement via Arm Pushoff (LEAP) approach is described and progress to date is presented.

  2. In situ fluorescence activation of DNA-silver nanoclusters as a label-free and general strategy for cell nucleus imaging.

    PubMed

    Li, Duo; Qiao, Zhenzhen; Yu, Yanru; Tang, Jinlu; He, Xiaoxiao; Shi, Hui; Ye, Xiaosheng; Lei, Yanli; Wang, Kemin

    2018-01-25

    A facile, general and turn-on nucleus imaging strategy was first developed based on in situ fluorescence activation of C-rich dark silver nanoclusters by G-rich telomeres. After a simple incubation without washing, nanoclusters could selectively stain the nucleus with intense red luminescence, which was confirmed using fixed/living cells and several cell lines.

  3. Advanced development of immobilized enzyme reactors

    NASA Technical Reports Server (NTRS)

    Jolly, Clifford D.; Schussel, Leonard J.; Carter, Layne

    1991-01-01

    Fixed-bed reactors have been used at NASA-Marshall to purify wastewater generated by an end-use equipment facility, on the basis of a combination of multifiltration unibeds and enzyme unibeds. The enzyme beds were found to effectively remove such targeted organics as urea, alcohols, and aldehydes, down to levels lying below detection limits. The enzyme beds were also found to remove organic contaminants not specifically targeted.

  4. Terminal configured vehicle program: Test facilities guide

    NASA Technical Reports Server (NTRS)

    1980-01-01

    The terminal configured vehicle (TCV) program was established to conduct research and to develop and evaluate aircraft and flight management system technology concepts that will benefit conventional take off and landing operations in the terminal area. Emphasis is placed on the development of operating methods for the highly automated environment anticipated in the future. The program involves analyses, simulation, and flight experiments. Flight experiments are conducted using a modified Boeing 737 airplane equipped with highly flexible display and control equipment and an aft flight deck for research purposes. The experimental systems of the Boeing 737 are described including the flight control computer systems, the navigation/guidance system, the control and command panel, and the electronic display system. The ground based facilities used in the program are described including the visual motion simulator, the fixed base simulator, the verification and validation laboratory, and the radio frequency anechoic facility.

  5. KSC-2009-6454

    NASA Image and Video Library

    2009-11-19

    CAPE CANAVERAL, Fla. – At NASA's Kennedy Space Center in Florida, recipients of a NASA Team Award for their parts in the successful construction of NASA's first large-scale solar power generation facility pose for a group portrait. Representatives from NASA, Florida Power & Light Company, or FPL, and SunPower Corporation formally commissioned the one-megawatt facility and announced plans to pursue a new research, development and demonstration project at Kennedy to advance America's use of renewable energy. The facility is the first element of a major renewable energy project currently under construction at Kennedy. The completed system features a fixed-tilt, ground-mounted solar power system designed and built by SunPower, along with SunPower solar panels. A 10-megawatt solar farm, which SunPower is building on nearby Kennedy property, will supply power to FPL's customers when it is completed in April 2010. Photo credit: NASA/Jim Grossmann

  6. KSC-2009-6451

    NASA Image and Video Library

    2009-11-19

    CAPE CANAVERAL, Fla. – Florida Power & Light Company Vice President and Chief Development Officer Eric Silagy, left, and NASA Kennedy Space Center Director Bob Cabana, center, examine one of the solar panels at the unveiling of NASA's first large-scale solar power generation facility at Kennedy in Florida. Representatives from NASA, Florida Power & Light Company, or FPL, and SunPower Corporation formally commissioned the one-megawatt facility and announced plans to pursue a new research, development and demonstration project at Kennedy to advance America's use of renewable energy. The facility is the first element of a major renewable energy project currently under construction at Kennedy. The completed system features a fixed-tilt, ground-mounted solar power system designed and built by SunPower, along with SunPower solar panels. A 10-megawatt solar farm, which SunPower is building on nearby Kennedy property, will supply power to FPL's customers when it is completed in April 2010. Photo credit: NASA/Jim Grossmann

  7. Development and application of a Controlled Release Facility (CRF) to validate flux quantifying methodologies.

    NASA Astrophysics Data System (ADS)

    Helmore, Jonathan

    2017-04-01

    The National Physical Laboratory, the UK's National Measurement Institute, has developed a novel facility capable of replicating the gaseous emission flux characteristics of a variety of real-word scenarios as may be found in small to medium scale industry and agriculture. The Controlled Release Facility (CRF) can be used to challenge conventional remote sensing techniques, as well as validate new Unmanned Aerial Vehicle (UAV) and distributed sensor network based methods, for source identification and flux calculation. The CRF method will be described and the results from three case studies will be discussed: The replication of an operational on-shore shale gas well using emissions of natural gas to atmosphere and measurements using Differential Absorption LIDAR (DIAL); the replication of fugitive volatile organic compounds emissions from a petrochemical unit and measurements using DIAL; and the replication of methane and carbon dioxide emissions from landfill and measurements using both fixed wing and multi-rotor UAVs.

  8. Ownership conversions and nursing home performance.

    PubMed

    Grabowski, David C; Stevenson, David G

    2008-08-01

    To examine the effects of ownership conversions on nursing home performance. Online Survey, Certification, and Reporting system data from 1993 to 2004, and the Minimum Data Set (MDS) facility reports from 1998 to 2004. Regression specification incorporating facility fixed effects, with terms to identify trends in the pre- and postconversion periods. The annual rate of nursing home conversions almost tripled between 1994 and 2004. Our regression results indicate converting facilities are generally different throughout the pre/postconversion years, suggesting little causal effect of ownership conversions on nursing home performance. Before and after conversion, nursing homes converting from nonprofit to for-profit status generally exhibit deterioration in their performance, while nursing homes converting from for-profit to nonprofit status generally exhibit improvement. Policy makers have expressed concern regarding the implications of ownership conversions for nursing home performance. Our results imply that regulators and policy makers should not only monitor the outcomes of nursing home conversions, but also the targets of these conversions.

  9. Methodological approach towards the definition of new storage conditions for inert wastes.

    PubMed

    Perrodin, Y; Méhu, J; Grelier-Volatier, L; Charbonnierb, P; Baranger, P; Thoraval, L

    2002-01-01

    In 1997, the French Ministry of Environment launched studies aiming to define a specific regulation concerning inert waste disposal in order to limit potential impact of such facilities on the environment by fixing minimum requirements. A model (chemical model/hydrodynamic model) was developed to determine dumping conditions. This model was then applied on two defined scenarios (landfill surface, effective rainfalls...) in order to study the sulphate concentrations in aquifer system immediately downstream from the storage facility. Results allow us to determine in which conditions the sulphates concentrations are compatibles with the potentially drinkable character of the groundwater. They more specifically concern the nature of the waste disposed of, the efficient rainfalls and the landfill area.

  10. Facilities maintenance handbook

    NASA Technical Reports Server (NTRS)

    1991-01-01

    This handbook is a guide for facilities maintenance managers. Its objective is to set minimum facilities maintenance standards. It also provides recommendations on how to meet the standards to ensure that NASA maintains its facilities in a manner that protects and preserves its investment in the facilities in a cost-effective manner while safely and efficiently performing its mission. This handbook implements NMI 8831.1, which states NASA facilities maintenance policy and assigns organizational responsibilities for the management of facilities maintenance activities on all properties under NASA jurisdiction. It is a reference for facilities maintenance managers, not a step-by-step procedural manual. Because of the differences in NASA Field Installation organizations, this handbook does not assume or recommend a typical facilities maintenance organization. Instead, it uses a systems approach to describe the functions that should be included in any facilities maintenance management system, regardless of its organizational structure. For documents referenced in the handbook, the most recent version of the documents is applicable. This handbook is divided into three parts: Part 1 specifies common definitions and facilities maintenance requirements and amplifies the policy requirements contained in NMI 8831. 1; Part 2 provides guidance on how to meet the requirements of Part 1, containing recommendations only; Part 3 contains general facilities maintenance information. One objective of this handbook is to fix commonality of facilities maintenance definitions among the Centers. This will permit the application of uniform measures of facilities conditions, of the relationship between current replacement value and maintenance resources required, and of the backlog of deferred facilities maintenance. The utilization of facilities maintenance system functions will allow the Centers to quantitatively define maintenance objectives in common terms, prepare work plans, and develop management information in order to statistically identify and analyze variances from those plans. It will also add credibility to the NASA facilities maintenance budgeting process. The key to a successful maintenance program is the understanding and support of the senior Center managers.

  11. Nurse staffing and deficiencies in the largest for-profit nursing home chains and chains owned by private equity companies.

    PubMed

    Harrington, Charlene; Olney, Brian; Carrillo, Helen; Kang, Taewoon

    2012-02-01

    To compare staffing levels and deficiencies of the 10 largest U.S. for-profit nursing home chains with five other ownership groups and chain staffing and deficiencies before and after purchase by four private equity (PE) companies. Facilities for the largest for-profit chains were identified through Internet searches and company reports and matched with federal secondary data for 2003-2008 for each ownership group. Descriptive statistics and generalized estimation equation panel regression models examined staffing and deficiencies by ownership groups in the 2003-2008 period, controlling for facility characteristics, resident acuity, and market factors with state fixed effects. The top 10 for-profit chains had lower registered nurse and total nurse staffing hours than government facilities, controlling for other factors. The top 10 chains received 36 percent higher deficiencies and 41 percent higher serious deficiencies than government facilities. Other for-profit facilities also had lower staffing and higher deficiencies than government facilities. The chains purchased by PE companies showed little change in staffing levels, but the number of deficiencies and serious deficiencies increased in some postpurchase years compared with the prepurchase period. There is a need for greater study of large for-profit chains as well as those chains purchased by PE companies. © Health Research and Educational Trust.

  12. Observing a light dark matter beam with neutrino experiments

    NASA Astrophysics Data System (ADS)

    Deniverville, Patrick; Pospelov, Maxim; Ritz, Adam

    2011-10-01

    We consider the sensitivity of fixed-target neutrino experiments at the luminosity frontier to light stable states, such as those present in models of MeV-scale dark matter. To ensure the correct thermal relic abundance, such states must annihilate via light mediators, which in turn provide an access portal for direct production in colliders or fixed targets. Indeed, this framework endows the neutrino beams produced at fixed-target facilities with a companion “dark matter beam,” which may be detected via an excess of elastic scattering events off electrons or nuclei in the (near-)detector. We study the high-luminosity proton fixed-target experiments at LSND and MiniBooNE, and determine that the ensuing sensitivity to light dark matter generally surpasses that of other direct probes. For scenarios with a kinetically-mixed U(1)' vector mediator of mass mV, we find that a large volume of parameter space is excluded for mDM˜1-5MeV, covering vector masses 2mDM≲mV≲mη and a range of kinetic mixing parameters reaching as low as κ˜10-5. The corresponding MeV-scale dark matter scenarios motivated by an explanation of the galactic 511 keV line are thus strongly constrained.

  13. A comparison of absolute calibrations of a radiation thermometer based on a monochromator and a tunable source

    NASA Astrophysics Data System (ADS)

    Keawprasert, T.; Anhalt, K.; Taubert, D. R.; Sperling, A.; Schuster, M.; Nevas, S.

    2013-09-01

    An LP3 radiation thermometer was absolutely calibrated at a newly developed monochromator-based set-up and the TUneable Lasers in Photometry (TULIP) facility of PTB in the wavelength range from 400 nm to 1100 nm. At both facilities, the spectral radiation of the respective sources irradiates an integrating sphere, thus generating uniform radiance across its precision aperture. The spectral irradiance of the integrating sphere is determined via an effective area of a precision aperture and a Si trap detector, traceable to the primary cryogenic radiometer of PTB. Due to the limited output power from the monochromator, the absolute calibration was performed with the measurement uncertainty of 0.17 % (k = 1), while the respective uncertainty at the TULIP facility is 0.14 %. Calibration results obtained by the two facilities were compared in terms of spectral radiance responsivity, effective wavelength and integral responsivity. It was found that the measurement results in integral responsivity at the both facilities are in agreement within the expanded uncertainty (k = 2). To verify the calibration accuracy, the absolutely calibrated radiation thermometer was used to measure the thermodynamic freezing temperatures of the PTB gold fixed-point blackbody.

  14. Maternal and perinatal mortality by place of delivery in sub-Saharan Africa: a meta-analysis of population-based cohort studies.

    PubMed

    Chinkhumba, Jobiba; De Allegri, Manuela; Muula, Adamson S; Robberstad, Bjarne

    2014-09-28

    Facility-based delivery has gained traction as a key strategy for reducing maternal and perinatal mortality in developing countries. However, robust evidence of impact of place of delivery on maternal and perinatal mortality is lacking. We aimed to estimate the risk of maternal and perinatal mortality by place of delivery in sub-Saharan Africa. We conducted a systematic review of population-based cohort studies reporting on risk of maternal or perinatal mortality at the individual level by place of delivery in sub-Saharan Africa. Newcastle-Ottawa Scale was used to assess study quality. Outcomes were summarized in pooled analyses using fixed and random effects models. We calculated attributable risk percentage reduction in mortality to estimate exposure effect. We report mortality ratios, crude odds ratios and associated 95% confidence intervals. We found 9 population-based cohort studies: 6 reporting on perinatal and 3 on maternal mortality. The mean study quality score was 10 out of 15 points. Control for confounders varied between the studies. A total of 36,772 pregnancy episodes were included in the analyses. Overall, perinatal mortality is 21% higher for home compared to facility-based deliveries, but the difference is only significant when produced with a fixed effects model (OR 1.21, 95% CI: 1.02-1.46) and not when produced by a random effects model (OR 1.21, 95% CI: 0.79-1.84). Under best settings, up to 14 perinatal deaths might be averted per 1000 births if the women delivered at facilities instead of homes. We found significantly increased risk of maternal mortality for facility-based compared to home deliveries (OR 2.29, 95% CI: 1.58-3.31), precluding estimates of attributable risk fraction. Evaluating the impact of facility-based delivery strategy on maternal and perinatal mortality using population-based studies is complicated by selection bias and poor control of confounders. Studies that pool data at an individual level may overcome some of these problems and provide better estimates of relative effectiveness of place of delivery in the region.

  15. [Business administration of PET facilities: a cost analysis of three facilities utilizing delivery FDG].

    PubMed

    Mitsutake, Naohiro; Oku, Shinya; Fujii, Ryo; Furui, Yuji; Yasunaga, Hideo

    2008-05-01

    PET (positron emission tomography) has been proved to be a powerful imaging tool in clinical oncology. The number of PET facilities in Japan has remarkably increased over the last decade. Furthermore, the approval of delivery FDG in 2005 resulted in a tremendous expansion of the PET institutions without a cyclotron facility. The aim of this study was to conduct a cost analysis of PET institutions that utilized delivery FDG. Three PET facilities using delivery FDG were investigated about the costs for PET service. Fixed costs included depreciation costs for construction and medical equipments such as positron camera. Variable costs consisted of costs for medical materials including delivery FDG. The break-even point was analyzed in each of three institutions. In the three hospitals (A, B and C), the annual number of PET scan was 1,591, 1,637 and 914, while cost per scan was accounted as yen 110,262, yen 111,091, and yen 134,192, respectively. The break-even point was calculated to be 2,583, 2,679 and 2,081, respectively. PET facilities utilizing delivery FDG seemed to have difficulty in business administration. Such a situation suggests the possibility that the current supply of PET facilities might exceed actual demand for the service. The efficiency of resource allocation should be taken into consideration in the future health service researches on PET.

  16. The unified database for the fixed target experiment BM@N

    NASA Astrophysics Data System (ADS)

    Gertsenberger, K. V.

    2016-09-01

    The article describes the developed database designed as comprehensive data storage of the fixed target experiment BM@N [1] at Joint Institute for Nuclear Research (JINR) in Dubna. The structure and purposes of the BM@N facility will be briefly presented. The scheme of the unified database and its parameters will be described in detail. The use of the BM@N database implemented on the PostgreSQL database management system (DBMS) allows one to provide user access to the actual information of the experiment. Also the interfaces developed for the access to the database will be presented. One was implemented as the set of C++ classes to access the data without SQL statements, the other-Web-interface being available on the Web page of the BM@N experiment.

  17. STS-30 crewmembers pose for informal portrait on JSC FB-SMS middeck

    NASA Image and Video Library

    1988-11-15

    S88-52187 (22 Nov 1988) --- Five astronauts pause from their training schedule to pose for a photograph. Pictured, left to right, are astronauts David M. Walker, mission commander; Mark C. Lee, Mary L. Cleave, Ronald J. Grabe and Norman E. Thagard. They are on the middeck section of the Shuttle mission simulator (fixed base) in the Johnson Space Center's mission simulation and training facility.

  18. STS-44 Atlantis, OV-104, MS Musgrave on FB-SMS middeck during JSC training

    NASA Technical Reports Server (NTRS)

    1991-01-01

    STS-44 Atlantis, Orbiter Vehicle (OV) 104, Mission Specialist (MS) F. Story Musgrave, wearing lightweight headset (HDST), adjusts controls on communications module mounted on a middeck overhead panel. Musgrave is on the middeck of the Fixed Base (FB) Shuttle Mission Simulator (SMS) located in JSC's Mission Simulation and Training Facility Bldg 5. The STS-44 crewmembers are participating in a flight simulation.

  19. Y2K: the moment of truth.

    PubMed

    Chepesiuk, R

    1999-05-01

    It remains to be seen whether the world will move in time to fix the Y2K bug, or whether computers around the world will shut down when the clock strikes midnight on 31 December 1999. Y2K could have a serious impact on environmental facilities, particularly given the extent to which computer software and microchips are now involved in pollution control and environmental monitoring and protection systems.

  20. Y2K: the moment of truth.

    PubMed Central

    Chepesiuk, R

    1999-01-01

    It remains to be seen whether the world will move in time to fix the Y2K bug, or whether computers around the world will shut down when the clock strikes midnight on 31 December 1999. Y2K could have a serious impact on environmental facilities, particularly given the extent to which computer software and microchips are now involved in pollution control and environmental monitoring and protection systems. PMID:10210702

  1. Report on the FY 1986 Activities of the Defense Science Study Group. Volume 1.

    DTIC Science & Technology

    1987-05-01

    Reactors Improved Techniques for Wavefront Sensing and Correction in Adaptive Optics Hypervelocity Launchers Underground Facilities 0 Automated...oceanography and sound propagation in partially coherent media such as the turbulent ocean. There are large fixed arrays such as the Sound Surveillance System...Aircraft Continuous Patrol Aircraft Miscellaneous Studies Review of the Plutonium Special Isotope Separation Program of the DOE 4r Fusion Fission Hybrid

  2. Rubbertown NGEM Demonstration Project Planning meetings ...

    EPA Pesticide Factsheets

    From the shared perspective of industrial facilities, workers, regulators, and communities, cost-effective detection and assessment of significant onset fugitive leaks or process issues, is a mutually beneficial concept. If emissions that require mitigation can be detected and fixed quickly, benefits such as safer working environments, cost saving through reduced product loss, lower air shed pollutant impacts, and improved transparency and community relations can be realized. Under its next generation emission measurement program (NGEM), EPA’s Office of Research and Development (ORD), National Risk Management Research Laboratory (NRMRL) is working collaboratively with industry, instrument /information companies, state and local agencies, communities, and academic groups to explore new technical approaches for non-point source detection and migration. Techniques such as mobile and fixed point sensors and passive samplers employed on various spatial scales are being explored. With collaboration of the project team including EPA R4, the Louisville Metro Air Pollution Control District (LMAPCD), industrial facilities, and contractors to the EPA, a select subset of these NGEM approaches will be demonstrated in this project as per the quality assurance project plan. From April 17-20, 2017, E. Thoma will travel to Louisville KY to work with the Louisville Metro Air Pollution Control District (LMAPCD) and other parties for planning activities related to the

  3. Fixed point Open Ocean Observatory network (FixO3): Multidisciplinary observations from the air-sea interface to the deep seafloor

    NASA Astrophysics Data System (ADS)

    Lampitt, Richard; Cristini, Luisa

    2014-05-01

    The Fixed point Open Ocean Observatory network (FixO3) seeks to integrate the 23 European open ocean fixed point observatories and to improve access to these key installations for the broader community. These will provide multidisciplinary observations in all parts of the oceans from the air-sea interface to the deep seafloor. Coordinated by the National Oceanography Centre, UK, FixO3 builds on the significant advances achieved through the previous Europe-funded FP7 programmes EuroSITES, ESONET and CARBOOCEAN. Started in September 2013 with a budget of 7 Million Euros over 4 years the project has 29 partners drawn from academia, research institutions and SME's. In addition 12 international experts from a wide range of disciplines comprise an Advisory Board. On behalf of the FixO3 Consortium, we present the programme that will be achieved through the activities of 12 Work Packages: 1. Coordination activities to integrate and harmonise the current procedures and processes. Strong links will be fostered with the wider community across academia, industry, policy and the general public through outreach, knowledge exchange and training. 2. Support actions to offer a) free access to observatory infrastructures to those who do not have such access, and b) free and open data services and products. 3. Joint research activities to innovate and enhance the current capability for multidisciplinary in situ ocean observation. Support actions include Transnational Access (TNA) to FixO3 infrastructure, meaning that European organizations can apply to free-of-charge access to the observatories for research and testing in two international calls during the project lifetime. The first call for TNA opens in summer 2014. More information can be found on FixO3 website (www.fixo3.eu/). Open ocean observation is currently a high priority for European marine and maritime activities. FixO3 will provide important data on environmental products and services to address the Marine Strategy Framework Directive and in support of the European Integrated Maritime Policy. The FixO3 network will provide free and open access to in situ fixed point data of the highest quality. It will provide a strong integrated framework of open ocean facilities in the Atlantic from the Arctic to the Antarctic and throughout the Mediterranean, enabling an integrated, regional and multidisciplinary approach to understand natural and anthropogenic change in the ocean.

  4. Nuclear Rocket Facility Decommissioning Project: Controlled Explosive Demolition of Neutron-Activated Shield Wall

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Michael R. Kruzic

    2008-06-01

    Located in Area 25 of the Nevada Test Site (NTS), the Test Cell A (TCA) Facility (Figure 1) was used in the early to mid-1960s for testing of nuclear rocket engines, as part of the Nuclear Rocket Development Program, to further space travel. Nuclear rocket testing resulted in the activation of materials around the reactors and the release of fission products and fuel particles. The TCA facility, known as Corrective Action Unit 115, was decontaminated and decommissioned (D&D) from December 2004 to July 2005 using the Streamlined Approach for Environmental Restoration (SAFER) process, under the Federal Facility Agreement and Consentmore » Order. The SAFER process allows environmental remediation and facility closure activities (i.e., decommissioning) to occur simultaneously, provided technical decisions are made by an experienced decision maker within the site conceptual site model. Facility closure involved a seven-step decommissioning strategy. First, preliminary investigation activities were performed, including review of process knowledge documentation, targeted facility radiological and hazardous material surveys, concrete core drilling and analysis, shield wall radiological characterization, and discrete sampling, which proved to be very useful and cost-effective in subsequent decommissioning planning and execution and worker safety. Second, site setup and mobilization of equipment and personnel were completed. Third, early removal of hazardous materials, including asbestos, lead, cadmium, and oil, was performed ensuring worker safety during more invasive demolition activities. Process piping was to be verified void of contents. Electrical systems were de-energized and other systems were rendered free of residual energy. Fourth, areas of high radiological contamination were decontaminated using multiple methods. Contamination levels varied across the facility. Fixed beta/gamma contamination levels ranged up to 2 million disintegrations per minute (dpm)/100 centimeters squared (cm2) beta/gamma. Removable beta/gamma contamination levels seldom exceeded 1,000 dpm/100 cm2, but, in railroad trenches on the reactor pad containing soil on the concrete pad in front of the shield wall, the beta dose rates ranged up to 120 milli-roentgens per hour from radioactivity entrained in the soil. General area dose rates were less than 100 micro-roentgens per hour. Prior to demolition of the reactor shield wall, removable and fixed contaminated surfaces were decontaminated to the best extent possible, using traditional decontamination methods. Fifth, large sections of the remaining structures were demolished by mechanical and open-air controlled explosive demolition (CED). Mechanical demolition methods included the use of conventional demolition equipment for removal of three main buildings, an exhaust stack, and a mobile shed. The 5-foot (ft), 5-inch (in.) thick, neutron-activated reinforced concrete shield was demolished by CED, which had never been performed at the NTS.« less

  5. Several twilight bolides over Kiev in 2013-2015 - fragments of comets nuclei

    NASA Astrophysics Data System (ADS)

    Churyumov, K. I.; Steklov, A. F.; Vidmachenko, A. P.; Dashkiev, G. N.

    2016-06-01

    During the short period of our observations (from March 2013 to 2015), was fixed falling at least a dozen fragments of cometary nuclei, at least five of sufficiently large and dozens of smaller fragments of meteoroids. The results of our observations also showed that during the morning and evening twilight over Kiev clearly visible the plume of aerosols of technical nature from the plants, factories and other production facilities.

  6. STS-49 crew in JSC's FB Shuttle Mission Simulator (SMS) during simulation

    NASA Technical Reports Server (NTRS)

    1992-01-01

    STS-49 Endeavour, Orbiter Vehicle (OV) 105, crewmembers participate in a simulation in JSC's Fixed Base (FB) Shuttle Mission Simulator (SMS) located in the Mission Simulation and Training Facility Bldg 5. Wearing launch and entry suits (LESs) and launch and entry helmets (LEH) and seated on the FB-SMS middeck are (left to right) Mission Specialist (MS) Thomas D. Akers, MS Kathryn C. Thornton, and MS Pierre J. Thuot.

  7. KSC-06pd0734

    NASA Image and Video Library

    2006-04-25

    KENNEDY SPACE CENTER, FLA. - While STS-121 Mission Specialist Michael Fossum (center) fixes his glove, Commander Steven Lindsey (left) and Mission Specialist Piers Sellers (right) talk about their next step in the Crew Equipment Interface Test at the SPACEHAB facility in Cape Canaveral. This test allows the astronauts to become familiar with equipment they will be using on their upcoming mission. STS-121 is scheduled to launch in July aboard Space Shuttle Discovery. Photo credit: NASA/Kim Shiflett

  8. Research Needs to Reduce Maritime Collisions, Rammings, and Groundings.

    DTIC Science & Technology

    1981-05-01

    increasingly important as sources of oil and minerals. Thus, the maritime industry must now accommodate unfamiliar fixed and mobile facilities, different...vulnerable to the influence of the press. The news media’s ability to mobilize public opinion for or against any industry, including the maritime industry...allocation for maritime and aeronautical mobile radio service) RTCM Supplement to paper 37-77/SC-69-70, Special Committee 60 Report on Marine Radio

  9. BPMs with Precise Alignment for TTF2

    NASA Astrophysics Data System (ADS)

    Noelle, D.; Priebe, G.; Wendt, M.; Werner, M.

    2004-11-01

    Design and technology of the new, standardized BPM-system for the warm sections of the TESLA Test Facility phase II (TTF2) are presented. Stripline- and button-BPM pickups are read-out with an upgraded version of the AM/PM BPM-electronics of TTF1. The Stripline-BPMs are fixed inside the quadrupole magnets. A stretched wire measurement was used to calibrate the electrical axis of the BPM wrt. to the magnetic axis of the quadrupole.

  10. KSC-04pd1401

    NASA Image and Video Library

    2004-07-02

    KENNEDY SPACE CENTER, FLA. - NASCAR Busch Series race driver Tim Fedewa completes his tour of KSC with a view from an upper level of the Fixed Service Structure on Launch Pad 39A. The Vehicle Assembly Building is in the background. Fedewa is touring KSC for the Speed Channel TV show “NBS 24/7,” which is devoted to NASCAR. Other sites on his tour are the Launch Control Center, Vehicle Assembly Building and the Orbiter Processing Facility.

  11. Nurse Staffing and Deficiencies in the Largest For-Profit Nursing Home Chains and Chains Owned by Private Equity Companies

    PubMed Central

    Harrington, Charlene; Olney, Brian; Carrillo, Helen; Kang, Taewoon

    2012-01-01

    Objective To compare staffing levels and deficiencies of the 10 largest U.S. for-profit nursing home chains with five other ownership groups and chain staffing and deficiencies before and after purchase by four private equity (PE) companies. Data Sources Facilities for the largest for-profit chains were identified through Internet searches and company reports and matched with federal secondary data for 2003–2008 for each ownership group. Study Design Descriptive statistics and generalized estimation equation panel regression models examined staffing and deficiencies by ownership groups in the 2003–2008 period, controlling for facility characteristics, resident acuity, and market factors with state fixed effects. Principal Findings The top 10 for-profit chains had lower registered nurse and total nurse staffing hours than government facilities, controlling for other factors. The top 10 chains received 36 percent higher deficiencies and 41 percent higher serious deficiencies than government facilities. Other for-profit facilities also had lower staffing and higher deficiencies than government facilities. The chains purchased by PE companies showed little change in staffing levels, but the number of deficiencies and serious deficiencies increased in some postpurchase years compared with the prepurchase period. Conclusions There is a need for greater study of large for-profit chains as well as those chains purchased by PE companies. PMID:22091627

  12. The ARM Climate Research Facility - New Capabilities and the Expected Impacts on Climate Science and Modeling

    NASA Astrophysics Data System (ADS)

    Voyles, J.; Mather, J. H.

    2010-12-01

    The ARM Climate Research Facility is a Department of Energy national scientific user facility. Research sites include fixed and mobile facilities, which collect research quality data for climate research. Through the American Recovery and Reinvestment Act of 2009, the U.S. Department of Energy’s Office of Science allocated $60 million to the ARM Climate Research Facility for the purchase of instruments and improvement of research sites. With these funds, ARM is in the process of deploying a broad variety of new instruments that will greatly enhance the measurement capabilities of the facility. New instruments being purchased include dual-frequency scanning cloud radars, scanning precipitation radars, Doppler lidars, a mobile Aerosol Observing System and many others. A list of instruments being purchased is available at http://www.arm.gov/about/recovery-act. Orders for all instruments have now been placed and activities are underway to integrate these new systems with our research sites. The overarching goal is to provide instantaneous and statistical measurements of the climate that can be used to advance the physical understanding and predictive performance of climate models. The Recovery Act investments enable the ARM Climate Research Facility to enhance existing and add new measurements, which enable a more complete understanding of the 3-dimensional evolution of cloud processes and related atmospheric properties. Understanding cloud processes are important globally, to reduce climate-modeling uncertainties and help improve our nation’s ability to manage climate impacts. Domer Plot of W-Band Reflectivity

  13. The next $120,000: a case study to illustrate analysis of alternative farm investments in fixed assets.

    PubMed

    St-Pierre, N R; Shoemaker, D; Jones, L R

    2000-05-01

    Dairy scientists specializing in the area of farm management are increasingly involved in analysis of farm investments in fixed assets. There have been instances where the wrong procedures were used to assess investments in fixed assets, leading to erroneous and possibly disastrous conclusions. A detailed case study of a dairy farm facing the decision of where best to invest an unexpected $120,000 windfall is used to illustrate the various facets of financial analysis. Indicators of profitability, liquidity, solvency, repayment capacity, and financial efficiency are explained and applied to the farm case to produce a detailed analysis of the current financial position of the firm. Long-range budgets of four alternate investment options and their impact on all financial indicators are presented. The four options are: 1) to pay down debt, 2) to purchase an additional 100 cows, 3) to install automatic milk yield recording in the parlor, and 4) to build new heifer facilities. All four investments are profitable. Therefore, an analysis limited to profitability indicators would conclude that any of the four options is a good investment. However, liquidity and financial efficiency issues showed that the option of purchasing 100 cows is far superior to the three others. We conclude that a complete and thorough financial analysis is required to evaluate the impact of long-run investments in fixed assets.

  14. New fixed-point mini-cell to investigate thermocouple drift in a high-temperature environment under neutron irradiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Laurie, M.; Vlahovic, L.; Rondinella, V.V.

    Temperature measurements in the nuclear field require a high degree of reliability and accuracy. Despite their sheathed form, thermocouples subjected to nuclear radiations undergo changes due to radiation damage and transmutation that lead to significant EMF drift during long-term fuel irradiation experiment. For the purpose of a High Temperature Reactor fuel irradiation to take place in the High Flux Reactor Petten, a dedicated fixed-point cell was jointly developed by LNE-Cnam and JRC-IET. The developed cell to be housed in the irradiation rig was tailor made to quantify the thermocouple drift during the irradiation (about two year duration) and withstand highmore » temperature (in the range 950 deg. C - 1100 deg. C) in the presence of contaminated helium in a graphite environment. Considering the different levels of temperature achieved in the irradiation facility and the large palette of thermocouple types aimed at surveying the HTR fuel pebble during the qualification test both copper (1084.62 deg. C) and gold (1064.18 deg. C) fixed-point materials were considered. The aim of this paper is to first describe the fixed-point mini-cell designed to be embedded in the reactor rig and to discuss the preliminary results achieved during some out of pile tests as much as some robustness tests representative of the reactor scram scenarios. (authors)« less

  15. The problem of bias when nursing facility staff administer customer satisfaction surveys.

    PubMed

    Hodlewsky, R Tamara; Decker, Frederic H

    2002-10-01

    Customer satisfaction instruments are being used with increasing frequency to assess and monitor residents' assessments of quality of care in nursing facilities. There is no standard protocol, however, for how or by whom the instruments should be administered when anonymous, written responses are not feasible. Researchers often use outside interviewers to assess satisfaction, but cost considerations may limit the extent to which facilities are able to hire outside interviewers on a regular basis. This study was designed to investigate the existence and extent of any bias caused by staff administering customer satisfaction surveys. Customer satisfaction data were collected in 1998 from 265 residents in 21 nursing facilities in North Dakota. Half the residents in each facility were interviewed by staff members and the other half by outside consultants; scores were compared by interviewer type. In addition to a tabulation of raw scores, ordinary least-squares analysis with facility fixed effects was used to control for resident characteristics and unmeasured facility-level factors that could influence scores. Significant positive bias was found when staff members interviewed residents. The bias was not limited to questions directly affecting staff responsibilities but applied across all types of issues. The bias was robust under varying constructions of satisfaction and dissatisfaction. A uniform method of survey administration appears to be important if satisfaction data are to be used to compare facilities. Bias is an important factor that should be considered and weighed against the costs of obtaining outside interviewers when assessing customer satisfaction among long term care residents.

  16. KSC-2009-6456

    NASA Image and Video Library

    2009-11-19

    CAPE CANAVERAL, Fla. – At NASA's Kennedy Space Center in Florida, Kennedy Director Bob Cabana, left, congratulates, Eric Silagy, Florida Power & Light Company vice president and chief development officer, for his part in the construction of NASA's first large-scale solar power generation facility as Roderick Roche, senior manager, Project Management Office of North America, SunPower Corporation, looks on. Representatives from NASA, Florida Power & Light Company, or FPL, and SunPower Corporation formally commissioned the one-megawatt facility and announced plans to pursue a new research, development and demonstration project at Kennedy to advance America's use of renewable energy. The facility is the first element of a major renewable energy project currently under construction at Kennedy. The completed system features a fixed-tilt, ground-mounted solar power system designed and built by SunPower, along with SunPower solar panels. A 10-megawatt solar farm, which SunPower is building on nearby Kennedy property, will supply power to FPL's customers when it is completed in April 2010. Photo credit: NASA/Jim Grossmann

  17. KSC-2009-6455

    NASA Image and Video Library

    2009-11-19

    CAPE CANAVERAL, Fla. – At NASA's Kennedy Space Center in Florida, Kennedy Director Bob Cabana, left, congratulates Roderick Roche, senior manager, Project Management Office of North America, SunPower Corporation, for his part in the construction of NASA's first large-scale solar power generation facility as Eric Silagy, Florida Power & Light Company vice president and chief development officer, looks on. Representatives from NASA, Florida Power & Light Company, or FPL, and SunPower Corporation formally commissioned the one-megawatt facility and announced plans to pursue a new research, development and demonstration project at Kennedy to advance America's use of renewable energy. The facility is the first element of a major renewable energy project currently under construction at Kennedy. The completed system features a fixed-tilt, ground-mounted solar power system designed and built by SunPower, along with SunPower solar panels. A 10-megawatt solar farm, which SunPower is building on nearby Kennedy property, will supply power to FPL's customers when it is completed in April 2010. Photo credit: NASA/Jim Grossmann

  18. Nursing Home Levels of Care: Reimbursement of Resident Specific Costs

    PubMed Central

    Willemain, Thomas R.

    1980-01-01

    The companion paper on nursing home levels of care (Bishop, Plough and Willemain, 1980) recommended a “split-rate” approach to nursing home reimbursement that would distinguish between fixed and variable costs. This paper examines three alternative treatments of the variable cost component of the rate: a two-level system similar to the distinction between skilled and intermediate care facilities, an individualized (“patient-centered”) system, and a system that assigns a single facility-specific rate that depends on the facility's case-mix (“case-mix reimbursement”). The aim is to better understand the theoretical strengths and weaknesses of these three approaches. The comparison of reimbursement alternatives is framed in terms of minimizing reimbursement error, meaning overpayment and underpayment. We develop a conceptual model of reimbursement error that stresses that the features of the reimbursement scheme are only some of the factors contributing to over- and underpayment. The conceptual model is translated into a computer program for quantitative comparison of the alternatives. PMID:10309330

  19. Nursing home levels of care: reimbursement of resident specific costs.

    PubMed

    Willemain, T R

    1980-01-01

    The companion paper on nursing home levels of care (Bishop, Plough and Willemain, 1980) recommended a "split-rate" approach to nursing home reimbursement that would distinguish between fixed and variable costs. This paper examines three alternative treatments of the variable cost component of the rate: a two-level system similar to the distinction between skilled and intermediate care facilities, an individualized ("patient-centered") system, and a system that assigns a single facility-specific rate that depends on the facility's case-mix ("case-mix reimbursement"). The aim is to better understand the theoretical strengths and weaknesses of these three approaches. The comparison of reimbursement alternatives is framed in terms of minimizing reimbursement error, meaning overpayment and underpayment. We develop a conceptual model of reimbursement error that stresses that the features of the reimbursement scheme are only some of the factors contributing to over- and underpayment. The conceptual model is translated into a computer program for quantitative comparison of the alternatives.

  20. Payment methods for outpatient care facilities

    PubMed Central

    Yuan, Beibei; He, Li; Meng, Qingyue; Jia, Liying

    2017-01-01

    Background Outpatient care facilities provide a variety of basic healthcare services to individuals who do not require hospitalisation or institutionalisation, and are usually the patient's first contact. The provision of outpatient care contributes to immediate and large gains in health status, and a large portion of total health expenditure goes to outpatient healthcare services. Payment method is one of the most important incentive methods applied by purchasers to guide the performance of outpatient care providers. Objectives To assess the impact of different payment methods on the performance of outpatient care facilities and to analyse the differences in impact of payment methods in different settings. Search methods We searched the Cochrane Central Register of Controlled Trials (CENTRAL), 2016, Issue 3, part of the Cochrane Library (searched 8 March 2016); MEDLINE, OvidSP (searched 8 March 2016); Embase, OvidSP (searched 24 April 2014); PubMed (NCBI) (searched 8 March 2016); Dissertations and Theses Database, ProQuest (searched 8 March 2016); Conference Proceedings Citation Index (ISI Web of Science) (searched 8 March 2016); IDEAS (searched 8 March 2016); EconLit, ProQuest (searched 8 March 2016); POPLINE, K4Health (searched 8 March 2016); China National Knowledge Infrastructure (searched 8 March 2016); Chinese Medicine Premier (searched 8 March 2016); OpenGrey (searched 8 March 2016); ClinicalTrials.gov, US National Institutes of Health (NIH) (searched 8 March 2016); World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) (searched 8 March 2016); and the website of the World Bank (searched 8 March 2016). In addition, we searched the reference lists of included studies and carried out a citation search for the included studies via ISI Web of Science to find other potentially relevant studies. We also contacted authors of the main included studies regarding any further published or unpublished work. Selection criteria Randomised trials, non-randomised trials, controlled before-after studies, interrupted time series, and repeated measures studies that compared different payment methods for outpatient health facilities. We defined outpatient care facilities in this review as facilities that provide health services to individuals who do not require hospitalisation or institutionalisation. We only included methods used to transfer funds from the purchaser of healthcare services to health facilities (including groups of individual professionals). These include global budgets, line-item budgets, capitation, fee-for-service (fixed and unconstrained), pay for performance, and mixed payment. The primary outcomes were service provision outcomes, patient outcomes, healthcare provider outcomes, costs for providers, and any adverse effects. Data collection and analysis At least two review authors independently extracted data and assessed the risk of bias. We conducted a structured synthesis. We first categorised the comparisons and outcomes and then described the effects of different types of payment methods on different categories of outcomes. We used a fixed-effect model for meta-analysis within a study if a study included more than one indicator in the same category of outcomes. We used a random-effects model for meta-analysis across studies. If the data for meta-analysis were not available in some studies, we calculated the median and interquartile range. We reported the risk ratio (RR) for dichotomous outcomes and the relative change for continuous outcomes. Main results We included 21 studies from Afghanistan, Burundi, China, Democratic Republic of Congo, Rwanda, Tanzania, the United Kingdom, and the United States of health facilities providing primary health care and mental health care. There were three kinds of payment comparisons. 1) Pay for performance (P4P) combined with some existing payment method (capitation or different kinds of input-based payment) compared to the existing payment method We included 18 studies in this comparison, however we did not include five studies in the effects analysis due to high risk of bias. From the 13 studies, we found that the extra P4P incentives probably slightly improved the health professionals' use of some tests and treatments (adjusted RR median = 1.095, range 1.01 to 1.17; moderate-certainty evidence), and probably led to little or no difference in adherence to quality assurance criteria (adjusted percentage change median = -1.345%, range -8.49% to 5.8%; moderate-certainty evidence). We also found that P4P incentives may have led to little or no difference in patients' utilisation of health services (adjusted RR median = 1.01, range 0.96 to 1.15; low-certainty evidence) and may have led to little or no difference in the control of blood pressure or cholesterol (adjusted RR = 1.01, range 0.98 to 1.04; low-certainty evidence). 2) Capitation combined with P4P compared to fee-for-service (FFS) One study found that compared with FFS, a capitated budget combined with payment based on providers' performance on antibiotic prescriptions and patient satisfaction probably slightly reduced antibiotic prescriptions in primary health facilities (adjusted RR 0.84, 95% confidence interval 0.74 to 0.96; moderate-certainty evidence). 3) Capitation compared to FFS Two studies compared capitation to FFS in mental health centres in the United States. Based on these studies, the effects of capitation compared to FFS on the utilisation and costs of services were uncertain (very low-certainty evidence). Authors' conclusions Our review found that if policymakers intend to apply P4P incentives to pay health facilities providing outpatient services, this intervention will probably lead to a slight improvement in health professionals' use of tests or treatments, particularly for chronic diseases. However, it may lead to little or no improvement in patients' utilisation of health services or health outcomes. When considering using P4P to improve the performance of health facilities, policymakers should carefully consider each component of their P4P design, including the choice of performance measures, the performance target, payment frequency, if there will be additional funding, whether the payment level is sufficient to change the behaviours of health providers, and whether the payment to facilities will be allocated to individual professionals. Unfortunately, the studies included in this review did not help to inform those considerations. Well-designed comparisons of different payment methods for outpatient health facilities in low- and middle-income countries and studies directly comparing different designs (e.g. different payment levels) of the same payment method (e.g. P4P or FFS) are needed. Payment methods for outpatient care facilities Review aim The aim of this Cochrane review was to assess the effect of different payment systems for outpatient care facilities. We collected and analysed all relevant studies to answer this question and included 21 studies. Key messages Pay-for-performance systems probably have only small benefits or make little or no difference to healthcare provider behaviour or patients' use of healthcare services. We are uncertain whether they cause harm. We are uncertain about the benefits and harms of other payments systems because the research is lacking or of very low certainty. What was studied in the review? Many healthcare services are offered to patients through outpatient facilities rather than to inpatients in hospitals. Outpatient facilities are also known as ambulatory care facilities, and include primary healthcare centres, outpatient clinics, urgent care centres, family planning centres, mental health centres, and dental clinics. Different systems to reimburse outpatient (ambulatory) care facilities for their services are available to governments and health insurers. These systems include: • budget systems, where the facility is given a fixed amount of money in advance to cover expenses for a fixed period; • capitation payment systems, where the facility is paid a fixed amount of money in advance to provide specific services to each enrolled patient for a fixed period; • fee-for-service systems, where payment is based on the specific services that the healthcare facility provides; • pay-for-performance systems, where payment is partly based on the performance of the facility's healthcare providers. Different payment systems can have different effects on how healthcare facilities deliver care. These changes can be intentional or unintentional and can lead to both benefits and harms. At best, a payment system can encourage healthcare providers to offer the right healthcare services to the right patients in the best and most cost-efficient way. However, payment systems can also lead providers to offer poor-quality, expensive, and unnecessary care, which can ultimately have a negative impact on patients' health. This Cochrane review assessed the effect of different payment systems for outpatient care facilities. Other Cochrane reviews have assessed the effect of different payment systems for individual healthcare professionals and for inpatient facilities. Main results We found 21 relevant studies from the United Kingdom, the United States, Rwanda, Burundi, Tanzania, Afghanistan, China, and Democratic Republic of Congo. Most of the studies were from primary healthcare facilities. The studies assessed capitation systems, fee-for-service systems, and different types of pay-for-performance systems. Pay-for-performance systems: • probably slightly improve providers' use of some tests and treatments; • probably lead to little or no difference in providers' compliance with quality assurance criteria; • may lead to little or no difference in patients' use of health services; • may lead to little or no difference in patients' health status. Capitation combined with a pay-for-performance system targeted at reducing antibiotic use probably slightly reduces antibiotic prescriptions when compared to a fee-for-service system. Two studies compared capitation with fee-for-service systems, however, we assessed the certainty of the evidence as very low. We did not find any relevant studies that assessed budget systems. How up-to-date is this review? We searched for studies that had been published up to March 2016. PMID:28253540

  1. Lower cost offshore field development utilizing autonomous vehicles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Frisbie, F.R.; Vie, K.J.; Welch, D.W.

    1996-12-31

    The offshore oil and gas industry has the requirement to inspect offshore oil and gas pipelines for scour, corrosion and damage as well as inspect and intervene on satellite production facilities. This task is currently performed with Remotely Operated Vehicles (ROV) operated from dynamically positioned (DP) offshore supply or diving support boats. Currently, these tasks are expensive due to the high day rates for DP ships and the slow, umbilical impeded, 1 knot inspection rates of the tethered ROVs, Emerging Autonomous Undersea Vehicle (AUV) technologies offer opportunities to perform these same inspection tasks for 50--75% lower cost, with comparable ormore » improved quality. The new generation LAPV (Linked Autonomous Power Vehicles) will operate from fixed facilities such as TLPs or FPFs and cover an operating field 10 kms in diameter.« less

  2. Vacuum Processing Technique for Development of Primary Standard Blackbodies

    PubMed Central

    Navarro, M.; Bruce, S. S.; Johnson, B. Carol; Murthy, A. V.; Saunders, R. D.

    1999-01-01

    Blackbody sources with nearly unity emittance that are in equilibrium with a pure freezing metal such as gold, silver, or copper are used as primary standard sources in the International Temperature Scale of 1990 (ITS-90). Recently, a facility using radio-frequency induction heating for melting and filling the blackbody crucible with the freeze metal under vacuum conditions was developed at the National Institute of Standards and Technology (NIST). The blackbody development under a vacuum environment eliminated the possibility of contamination of the freeze metal during the process. The induction heating, compared to a resistively heated convection oven, provided faster heating of crucible and resulted in shorter turn-around time of about 7 h to manufacture a blackbody. This paper describes the new facility and its application to the development of fixed-point blackbodies.

  3. Routine delivery of artemisinin-based combination treatment at fixed health facilities reduces malaria prevalence in Tanzania: an observational study

    PubMed Central

    2012-01-01

    Background Artemisinin-based combination therapy (ACT) has been promoted as a means to reduce malaria transmission due to their ability to kill both asexual blood stages of malaria parasites, which sustain infections over long periods and the immature derived sexual stages responsible for infecting mosquitoes and onward transmission. Early studies reported a temporal association between ACT introduction and reduced malaria transmission in a number of ecological settings. However, these reports have come from areas with low to moderate malaria transmission, been confounded by the presence of other interventions or environmental changes that may have reduced malaria transmission, and have not included a comparison group without ACT. This report presents results from the first large-scale observational study to assess the impact of case management with ACT on population-level measures of malaria endemicity in an area with intense transmission where the benefits of effective infection clearance might be compromised by frequent and repeated re-infection. Methods A pre-post observational study with a non-randomized comparison group was conducted at two sites in Tanzania. Both sites used sulphadoxine-pyrimethamine (SP) monotherapy as a first-line anti-malarial from mid-2001 through 2002. In 2003, the ACT, artesunate (AS) co-administered with SP (AS + SP), was introduced in all fixed health facilities in the intervention site, including both public and registered non-governmental facilities. Population-level prevalence of Plasmodium falciparum asexual parasitaemia and gametocytaemia were assessed using light microscopy from samples collected during representative household surveys in 2001, 2002, 2004, 2005 and 2006. Findings Among 37,309 observations included in the analysis, annual asexual parasitaemia prevalence in persons of all ages ranged from 11% to 28% and gametocytaemia prevalence ranged from <1% to 2% between the two sites and across the five survey years. A multivariable logistic regression model was fitted to adjust for age, socioeconomic status, bed net use and rainfall. In the presence of consistently high coverage and efficacy of SP monotherapy and AS + SP in the comparison and intervention areas, the introduction of ACT in the intervention site was associated with a modest reduction in the adjusted asexual parasitaemia prevalence of 5 percentage-points or 23% (p < 0.0001) relative to the comparison site. Gametocytaemia prevalence did not differ significantly (p = 0.30). Interpretation The introduction of ACT at fixed health facilities only modestly reduced asexual parasitaemia prevalence. ACT is effective for treatment of uncomplicated malaria and should have substantial public health impact on morbidity and mortality, but is unlikely to reduce malaria transmission substantially in much of sub-Saharan Africa where individuals are rapidly re-infected. PMID:22545573

  4. STS-30 crewmembers pose for informal portrait on JSC FB-SMS middeck

    NASA Technical Reports Server (NTRS)

    1988-01-01

    STS-30 Atlantis, Orbiter Vehicle (OV) 104, crewmembers pause briefly from their training schedule to pose for informal portrait in JSC fixed base (FB) shuttle mission simulator (SMS). On FB-SMS middeck are (left to right) Commander David M. Walker, Mission Specialist (MS) Mark C. Lee, MS Mary L. Cleave, Pilot Ronald J. Grabe, and MS Norman E. Thagard. FB-SMS is located in JSC's Mission Simulation and Training Facility Bldg 5.

  5. Feasibility study of heavy-ion collision physics at NICA JINR

    NASA Astrophysics Data System (ADS)

    Kekelidze, V.; Kovalenko, A.; Lednicky, R.; Matveev, V.; Meshkov, I.; Sorin, A.; Trubnikov, G.

    2017-11-01

    The project NICA (Nuclotron-based Ion Collider fAcility) is aimed to study hot and baryon rich QCD matter in heavy ion collisions in the energy range up to √{sNN} = 11GeV. The heavy ion program includes a study of collective phenomena, dilepton, hyperon and hypernuclei production under extreme conditions of highest baryonic density. This program will be performed at a fixed target experiment BM@N and with MPD detector at the NICA collider.

  6. A Procedure for Evaluating Subpotable Water Reuse Potential at Army Fixed Facilities.

    DTIC Science & Technology

    1981-11-01

    characteristic of phosphate waste waters from fume scrubbers. + Flue gas desulfurization sludge liquors. 75 Table B5 Base Housing Water Supply Quality (Also...ENGINEERING RESEARCH LABORATORY 4A762720A896-B-008 P.O. Box 4005, Champaign, IL 61820 1I. CONTROLLING OFFICE NAME AND ADDRESS 12. REPORT DATE November 1981 13...NUMBER OF PAGES 102 4. MONITORING AGENCY NAME & ADDRESS(If different from Controlling Office) IS. SECURITY CLASS. (of til, report) UNCLASSIFIED 15

  7. Analysis of Low Bidding and Change Order Rates for Navy Facilities Construction Contracts.

    DTIC Science & Technology

    1984-06-01

    examine his motives and strategies prior to bidding. Several measures of " level cf competitiveness" are introduced from bidding theory literature that...bidders of fixed-price Government construction contracts have on contract prices when the level FORM, 1473 EDITION OF INOV 6 o IS OBSOLETE S N 0 102...conventional measures of the . level of competition intensity are applied in regression and variance analyses. en, z e ., . , 144 , UNCLASSIFIED 2 SgCURITlY

  8. Cloud computing can simplify HIT infrastructure management.

    PubMed

    Glaser, John

    2011-08-01

    Software as a Service (SaaS), built on cloud computing technology, is emerging as the forerunner in IT infrastructure because it helps healthcare providers reduce capital investments. Cloud computing leads to predictable, monthly, fixed operating expenses for hospital IT staff. Outsourced cloud computing facilities are state-of-the-art data centers boasting some of the most sophisticated networking equipment on the market. The SaaS model helps hospitals safeguard against technology obsolescence, minimizes maintenance requirements, and simplifies management.

  9. The personal costs and convenience of screening mammography.

    PubMed

    Suter, Lisa Gale; Nakano, Connie Y; Elmore, Joann G

    2002-09-01

    Few studies have examined the impact of women's personal costs on obtaining a screening mammogram in the United States. All women obtaining screening mammograms at nine Connecticut mammography facilities during a 2-week study period were asked to complete a questionnaire. Facilities included urban and rural fixed sites and mobile sites. The survey included questions about insurance coverage, mammogram payment, and personal costs in terms of transportation, family care, parking, and lost work time from the women's perspective. The response rate was 62% (731 of 1189). Thirty-two percent of respondents incurred some type of personal cost, including lost work time, family care, and parking. Women incurring personal costs were more likely than those without personal costs to attend an urban facility (46% vs. 23%, p < 0.01) and be under the age of 50 (40% vs. 26%, p < 0.01). Overall, 61% of women listed convenience and 17% listed cost as a reason for choosing a mammography facility; 23% reported that cost might prevent them from obtaining a future mammogram. One third of women obtaining mammograms may be incurring personal costs. These personal costs should be considered in future cost-effectiveness analyses.

  10. Project Nuclotron-based Ion Collider fAcility at JINR

    NASA Astrophysics Data System (ADS)

    Kekelidze, V. D.; Matveev, V. A.; Meshkov, I. N.; Sorin, A. S.; Trubnikov, G. V.

    2017-09-01

    The project of Nuclotron-based Ion Collider fAcility (NICA) that is under development at JINR (Dubna) is presented. The general goals of the project are experimental studies of both hot and dense baryonic matter and spin physics (in collisions of polarized protons and deuterons). The first program requires providing of heavy ion collisions in the energy range of √ {{s_{NN}}} = 4-11 Gev at average luminosity of L = 1 × 1027 cm-2 s-1 for 197Au79+ nuclei. The polarized beams mode is proposed to be used in energy range of √ {{s_{NN}}} = 12-27 Gev (protons at luminosity of L ≥ 1 × 1030 cm-2 s-1. The report contains description of the facility scheme and its characteristics in heavy ion operation mode. The Collider will be equipped with two detectors—MultiPurpose Detector (MPD), which is in an active stage of construction, and Spin Physics Detector (SPD) that is in the stage of conceptual design. Fixed target experiment "Baryonic matter at Nuclotron" (BM@N) will be performed in very beginning of the project. The wide program of applied researches at NICA facility is being developed as well.

  11. Malpractice litigation and nursing home quality of care.

    PubMed

    Konetzka, R Tamara; Park, Jeongyoung; Ellis, Robert; Abbo, Elmer

    2013-12-01

    To assess the potential deterrent effect of nursing home litigation threat on nursing home quality. We use a panel dataset of litigation claims and Nursing Home Online Survey Certification and Reporting (OSCAR) data from 1995 to 2005 in six states: Florida, Illinois, Wisconsin, New Jersey, Missouri, and Delaware, for a total of 2,245 facilities. Claims data are from Westlaw's Adverse Filings database, a proprietary legal database, on all malpractice, negligence, and personal injury/wrongful death claims filed against nursing facilities. A lagged 2-year moving average of the county-level number of malpractice claims is used to represent the threat of litigation. We use facility fixed-effects models to examine the relationship between the threat of litigation and nursing home quality. We find significant increases in registered nurse-to-total staffing ratios in response to rising malpractice threat, and a reduction in pressure sores among highly staffed facilities. However, the magnitude of the deterrence effect is small. Deterrence in response to the threat of malpractice litigation is unlikely to lead to widespread improvements in nursing home quality. This should be weighed against other benefits and costs of litigation to assess the net benefit of tort reform. © Health Research and Educational Trust.

  12. Navy Safety Center data on the effects of fire protection systems on electrical equipment

    NASA Astrophysics Data System (ADS)

    Levine, Robert S.

    1991-04-01

    Records of the Navy Safety Center, Norfolk, VA were reviewed to find data relevant to inadvertant operation of installed fire extinguishing systems in civilian nuclear power plants. Navy data show the incidence of collateral fire or other damage by fresh water on operating electrical equipment in submarines and in shore facilities is about the same as the civilian experience, about 30 percent. Aboard surface ships, however, the collateral damage incidence in much lower, about 15 percent. With sea water, the collateral damage incidence is at least 75 percent. It is concluded that the fire extinguisher water has to be contaminated, as by rust in sprinkler systems or deposited salt spray, for most collateral damage to occur. Reasons for inadvertant operation (or advertant operation) of firex systems at shore facilities, submarines, and surface ships resemble those for nuclear power plants. Mechanical or electrical failures lead the list, followed by mishaps during maintenance. Detector and alarm system failures are significant problems at Navy shore facilities, and significant at nuclear power plants. Fixed halon and CO2 systems in shore facilities cause no collateral damage. Lists of individual Navy incidents with water and with halon and carbon dioxide are included as appendices.

  13. Beam efflux measurements

    NASA Technical Reports Server (NTRS)

    Komatsu, G. K.; Stellen, J. M., Jr.

    1976-01-01

    Measurements have been made of the high energy thrust ions, (Group I), high angle/high energy ions (Group II), and high angle/low energy ions (Group IV) of a mercury electron bombardment thruster in the angular divergence range from 0 deg to greater than 90 deg. The measurements have been made as a function of thrust ion current, propellant utilization efficiency, bombardment discharge voltage, screen and accelerator grid potential (accel-decel ratio) and neutralizer keeper potential. The shape of the Group IV (charge exchange) ion plume has remained essentially fixed within the range of variation of the engine operation parameters. The magnitude of the charge exchange ion flux scales with thrust ion current, for good propellant utilization conditions. For fixed thrust ion current, charge exchange ion flux increases for diminishing propellant utilization efficiency. Facility effects influence experimental accuracies within the range of propellant utilization efficiency used in the experiments. The flux of high angle/high energy Group II ions is significantly diminished by the use of minimum decel voltages on the accelerator grid. A computer model of charge exchange ion production and motion has been developed. The program allows computation of charge exchange ion volume production rate, total production rate, and charge exchange ion trajectories for "genuine" and "facilities effects" particles. In the computed flux deposition patterns, the Group I and Group IV ion plumes exhibit a counter motion.

  14. Identification of possible sources of particulate matter in the personal cloud using SEM/EDX

    NASA Astrophysics Data System (ADS)

    Conner, Teri L.; Williams, Ronald W.

    2004-10-01

    The United States Environmental Protection Agency (US EPA) conducted the Baltimore Particulate Matter (PM) Epidemiology-Exposure Study of the Elderly during the summer of 1998. The study design included PM2.5 samples obtained from elderly (65+ years of age) retirement facility residents using personal exposure sampling devices. These sampling devices were also used to obtain PM2.5 samples at fixed locations within the personal monitoring subjects' apartments. Selected personal and apartment samples were examined using scanning electron microscopy with individual-particle X-ray analysis (SEM/EDX), providing a qualitative assessment of the chemical and physical characteristics of geological and trace element particles collected within these micro-environments at the retirement facility. This information was used to identify possible indoor source particles. The manual surveys of the personal samples revealed that some particles larger than 2.5 μm reached the filter surface. Using SEM/EDX, several particle types with possible indoor origins were identified. The Al-Zr-Cl particle is likely to have originated from a personal antiperspirant product. Particles with a talc or alumino-silicate composition point to cosmetics as a possible source. Large cadmium-containing particles were also found, which may indicate the use of art pigments or ceramic glazes, or emissions from television screen phosphors. A greater variety of particles was observed in a personal sample compared with its corresponding fixed-location apartment sample.

  15. Scanning Cloud Radar Observations at the ARM sites

    NASA Astrophysics Data System (ADS)

    Kollias, P.; Clothiaux, E. E.; Shupe, M.; Widener, K.; Bharadwaj, N.; Miller, M. A.; Verlinde, H.; Luke, E. P.; Johnson, K. L.; Jo, I.; Tatarevic, A.; Lamer, K.

    2012-12-01

    Recently, the DOE Atmospheric Radiation Measurement (ARM) program upgraded its fixed and mobile facilities with the acquisition of state-of-the-art scanning, dual-wavelength, polarimetric, Doppler cloud radars. The scanning ARM cloud radars (SACR's) are the most expensive and significant radar systems at all ARM sites and eight SACR systems will be operational at ARM sites by the end of 2013. The SACR's are the primary instruments for the detection of 3D cloud properties (boundaries, volume cloud fractional coverage, liquid water content, dynamics, etc.) beyond the soda-straw (profiling) limited view. Having scanning capabilities with two frequencies and polarization allows more accurate probing of a variety of cloud systems (e.g., drizzle and shallow, warm rain), better correction for attenuation, use of attenuation for liquid water content retrievals, and polarimetric and dual-wavelength ratio characterization of non-spherical particles for improved ice crystal habit identification. Examples of SACR observations from four ARM sites are presented here: the fixed sites at Southern Great Plains (SGP) and North Slope of Alaska (NSA), and the mobile facility deployments at Graciosa Island, Azores and Cape Cod, Massachusetts. The 3D cloud structure is investigated both at the macro-scale (20-50 km) and cloud-scale (100-500 m). Doppler velocity measurements are corrected for velocity folding and are used either to describe the in-cloud horizontal wind profile or the 3D vertical air motions.

  16. Making the transition to workload-based staffing: using the Workload Indicators of Staffing Need method in Uganda.

    PubMed

    Namaganda, Grace; Oketcho, Vincent; Maniple, Everd; Viadro, Claire

    2015-08-31

    Uganda's health workforce is characterized by shortages and inequitable distribution of qualified health workers. To ascertain staffing levels, Uganda uses fixed government-approved norms determined by facility type. This approach cannot distinguish between facilities of the same type that have different staffing needs. The Workload Indicators of Staffing Need (WISN) method uses workload to determine number and type of staff required in a given facility. The national WISN assessment sought to demonstrate the limitations of the existing norms and generate evidence to influence health unit staffing and staff deployment for efficient utilization of available scarce human resources. A national WISN assessment (September 2012) used purposive sampling to select 136 public health facilities in 33/112 districts. The study examined staffing requirements for five cadres (nursing assistants, nurses, midwives, clinical officers, doctors) at health centres II (n = 59), III (n = 53) and IV (n = 13) and hospitals (n = 11). Using health management information system workload data (1 July 2010-30 June 2011), the study compared current and required staff, assessed workload pressure and evaluated the adequacy of the existing staffing norms. By the WISN method, all three types of health centres had fewer nurses (42-70%) and midwives (53-67%) than required and consequently exhibited high workload pressure (30-58%) for those cadres. Health centres IV and hospitals lacked doctors (39-42%) but were adequately staffed with clinical officers. All facilities displayed overstaffing of nursing assistants. For all cadres at health centres III and IV other than nursing assistants, the fixed norms or existing staffing or both fell short of the WISN staffing requirements, with, for example, only half as many nurses and midwives as required. The WISN results demonstrate the inadequacies of existing staffing norms, particularly for health centres III and IV. The results provide an evidence base to reshape policy, adopt workload-based norms, review scopes of practice and target human resource investments. In the near term, the government could redistribute existing health workers to improve staffing equity in line with the WISN results. Longer term revision of staffing norms and investments to effectively reflect actual workloads and ensure provision of quality services at all levels is needed.

  17. Potential cost-effectiveness of supervised injection facilities in Toronto and Ottawa, Canada.

    PubMed

    Enns, Eva A; Zaric, Gregory S; Strike, Carol J; Jairam, Jennifer A; Kolla, Gillian; Bayoumi, Ahmed M

    2016-03-01

    Supervised injection facilities (legally sanctioned spaces for supervised consumption of illicitly obtained drugs) are controversial public health interventions. We determined the optimal number of facilities in two Canadian cities using health economic methods. Dynamic compartmental model of HIV and hepatitis C transmission through sexual contact and sharing of drug use equipment. Toronto and Ottawa, Canada. Simulated population of each city. Zero to five supervised injection facilities. Direct health-care costs and quality-adjusted life-years (QALYs) over 20 years, discounted at 5% per year; incremental cost-effectiveness ratios. In Toronto, one facility cost $4.1 million and resulted in a gain of 385 QALYs over 20 years, for an incremental cost-effectiveness ratio (ICER) of $10,763 per QALY [95% credible interval (95CrI): cost-saving to $278,311]. Establishing one facility in Ottawa had an ICER of $6127 per QALY (95CrI: cost-saving to $179,272). At a $50,000 per QALY threshold, three facilities would be cost-effective in Toronto and two in Ottawa. The probability that establishing three, four, or five facilities in Toronto was cost-effective was 17, 21, and 41%, respectively. Establishing one, two, or three facilities in Ottawa was cost-effective with 13, 35, and 41% probability, respectively. Establishing no facility was unlikely to be the most cost-effective option (14% in Toronto and 10% in Ottawa). In both cities, results were robust if the reduction in needle-sharing among clients of the facilities was at least 50% and fixed operating costs were less than $2.0 million. Using a $50,000 per quality-adjusted life-years threshold for cost-effectiveness, it is likely to be cost-effective to establish at least three legally sanctioned spaces for supervised injection of illicitly obtained drugs in Toronto, Canada and two in Ottawa, Canada. © 2015 Society for the Study of Addiction.

  18. Hospitalizations Among Nursing Home Residents in the Last Year of Life: Nursing Home Characteristics and Variation in Potentially Avoidable Hospitalizations

    PubMed Central

    Xing, Jingping; Mukamel, Dana B.; Temkin-Greener, Helena

    2013-01-01

    Objectives 1) To examine the incidence, variations, and costs in potentially avoidable hospitalizations (PAHs) among nursing home (NH) residents at the end-of-life. 2) To identify the association between NH characteristics and a facility-level quality measure (QM) for PAH. Design Retrospective study. Setting Hospitalizations originating from NHs. Participants Long-term care NH residents who died in 2007. Measurements We constructed a risk-adjusted QM for PAH. Poisson regression model was used to predict the count of PAH given residents’ risk factors. For each facility, the QM was defined as the difference between the observed facility-specific rate (per 1,000 person-years) of PAH (O) and the expected risk-adjusted rate (E). We then fit a logistic regression model with state fixed-effects to examine the association between facility characteristics and the likelihood of having higher than expected rates of PAH (O-E>0). QM values higher than 0 indicate worse than average quality. Results Almost 50% of hospital admissions for NH residents in their last year of life were for potentially avoidable diagnoses, costing Medicare $1billion. Five conditions were responsible for over 80% of PAHs. PAH QM across facilities showed significant variation (mean=11.96; std dev=142.26; range: −399.48-398.09). Chain and hospital-based facilities were more likely to exhibit better performance (O-E<0). Facilities with higher nursing staffing were more likely to have better performance, as did facilities with higher skilled staff ratio, facilities with nurse practitioners/physician assistants, and those with on-site x-ray services. Conclusion Variations in facility-level PAHs suggest that a potential for reducing hospital admissions for these conditions may exist. Presence of modifiable facility characteristics associated with PAH performance provides insights into possible interventions for reducing PAHs at the end-of-life. PMID:24219191

  19. Piloted evaluation of an integrated propulsion and flight control simulator

    NASA Technical Reports Server (NTRS)

    Bright, Michelle M.; Simon, Donald L.

    1992-01-01

    This paper describes a piloted evaluation of the integrated flight and propulsion control simulator at NASA Lewis Research Center. The purpose of this evaluation is to demonstrate the suitability and effectiveness of this fixed based simulator for advanced integrated propulsion and airframe control design. The evaluation will cover control effector gains and deadbands, control effectiveness and control authority, and heads up display functionality. For this evaluation the flight simulator is configured for transition flight using an advanced Short Take-Off and vertical Landing fighter aircraft model, a simplified high-bypass turbofan engine model, fighter cockpit, displays, and pilot effectors. The paper describes the piloted tasks used for rating displays and control effector gains. Pilot comments and simulation results confirm that the display symbology and control gains are very adequate for the transition flight task. Additionally, it is demonstrated that this small-scale, fixed base flight simulator facility can adequately perform a real time, piloted control evaluation.

  20. State deregulation and Medicare costs for acute cardiac care.

    PubMed

    Ho, Vivian; Ku-Goto, Meei-Hsiang

    2013-04-01

    Past literature suggests that Certificate of Need (CON) regulations for cardiac care were ineffective in improving quality, but less is known about the effect of CON on patient costs. We analyzed Medicare data for 1991-2002 to test whether states that dropped CON experienced changes in costs or reimbursements for coronary artery bypass graft (CABG) surgery or percutaneous coronary interventions. We found that states that dropped CON experienced lower costs per patient for CABG but not for percutaneous coronary intervention. Average Medicare reimbursement was lower for both procedures in states that dropped CON. The cost savings from removing CON regulations slightly exceed the total fixed costs of new CABG facilities that entered after deregulation. Assuming continued cost savings past 2002, the savings from deregulating CABG surgery outweigh the fixed costs of new entry. Thus, CON regulations for CABG may not be justified in terms of either improving quality or controlling cost growth.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sun, Cheng-Jun, E-mail: cjsun@aps.anl.gov; Brewe, Dale L.; Heald, Steve M.

    X-ray diffraction (XRD) and X-ray absorption spectroscopy (XAS) are two main x-ray techniques in synchrotron radiation facilities. In this Note, we present an experimental setup capable of performing simultaneous XRD and XAS measurements by the application of a pixel-array area detector. For XRD, the momentum transfer in specular diffraction was measured by scanning the X-ray energy with fixed incoming and outgoing x-ray angles. By selecting a small fixed region of the detector to collect the XRD signal, the rest of the area was available for collecting the x-ray fluorescence for XAS measurements. The simultaneous measurement of XRD and X-ray absorptionmore » near edge structure for Pr{sub 0.67}Sr{sub 0.33}MnO{sub 3} film was demonstrated as a proof of principle for future time-resolved pump-probe measurements. A static sample makes it easy to maintain an accurate overlap of the X-ray spot and laser pump beam.« less

  2. The Shuttle Mission Simulator computer generated imagery

    NASA Technical Reports Server (NTRS)

    Henderson, T. H.

    1984-01-01

    Equipment available in the primary training facility for the Space Transportation System (STS) flight crews includes the Fixed Base Simulator, the Motion Base Simulator, the Spacelab Simulator, and the Guidance and Navigation Simulator. The Shuttle Mission Simulator (SMS) consists of the Fixed Base Simulator and the Motion Base Simulator. The SMS utilizes four visual Computer Generated Image (CGI) systems. The Motion Base Simulator has a forward crew station with six-degrees of freedom motion simulation. Operation of the Spacelab Simulator is planned for the spring of 1983. The Guidance and Navigation Simulator went into operation in 1982. Aspects of orbital visual simulation are discussed, taking into account the earth scene, payload simulation, the generation and display of 1079 stars, the simulation of sun glare, and Reaction Control System jet firing plumes. Attention is also given to landing site visual simulation, and night launch and landing simulation.

  3. Do resource utilization and clinical measures still vary across dialysis chains after controlling for the local practices of facilities and physicians?

    PubMed

    Hirth, Richard A; Turenne, Marc N; Wheeler, John R C; Ma, Yu; Messana, Joseph M

    2010-08-01

    Because of adverse survival effects, anemia management and financial incentives to increase doses of erythropoiesis-stimulating agents (ESAs) have been controversial. Prior studies showed more aggressive anemia management in dialysis facilities owned by for-profit chains, but have been criticized for not accounting for practices of individual physicians and facilities. To improve understanding of how dialysis practices and resource utilization are influenced by physicians, facilities, and chains. Mixed models with chain fixed effects and facility and physician random effects. Medicare hemodialysis patients in 2004. A total of 234,158 patients, 3995 facilities, 4838 physicians, and 7 chain classifications were included. Spending per session for dialysis-related services billed separately from the dialysis treatment and for ESAs. Achievement of hematocrit (HCT) and urea reduction ratio (URR) targets. Of the 4 largest for-profit chains, 3 had higher resource use than independents, with differences up to $17.92 higher ESA/session. Utilization was positively associated with achieving target HCT. Despite incurring lower costs, patients treated by a large nonprofit chain were as likely as patients of independents to achieve the HCT target. The largest chains were more likely than independents to achieve the URR target. Substantial variation occurred across physicians and facilities, and adjustment for chain only modestly decreased this variation. Chains' methods of influencing practices were not directly observed. Chains appear to have the ability to implement protocols that shift practices, but not the ability to substantially reduce local variation. Assertions that chain effects found by earlier studies were spurious are not supported.

  4. Scheduling and Delivering Aircraft to Departure Fixes in the NY Metroplex with Controller-Managed Spacing Tools

    NASA Technical Reports Server (NTRS)

    Chevalley, Eric; Parke, Bonny; Kraut, Josh M.; Bienert, Nancy; Omar, Faisal; Palmer, Everett A.

    2015-01-01

    In this paper, successful Time-Based Flow Management (TBFM) scheduling systems for arrivals are considered and adapted to apply to departures. We present a concept of operations that integrates Controller-Managed Spacing tools for departures (CMS-D) with existing tactical departure scheduling tools to coordinate demand at departure fixes in a metroplex environment. We tested our concept in a Human-in-the-Loop simulation and compared the effect of two scheduling conditions: 1) "Departure Scheduling" consisting of an emulation of the Integrated Departure and Arrival Capability (IDAC) where Towers and a Planner (Traffic Management Coordinator at the appropriate facility) coordinate aircraft scheduled takeoff times to departure fixes; and 2) "Arrival Sensitive Departure Scheduling" where, in addition, the Tower and Planner also consider arrival Scheduled Time of Arrivals (STAs) at the airport's dependent runway. Results indicate little difference between the two scheduling conditions, but a large difference between the No Tools and the two scheduling conditions with CMS-D tools. The scheduling/CMS-D tools conditions markedly reduced heading, speed clearances, and workload for controllers who were merging flows at the departure fixes. In the tool conditions, departure controllers conditioned departures earlier rather than later when aircraft were tied near the departure fixes. In the scheduling/CMS-D tools conditions, departures crossed the departure fixes 50 seconds earlier and with an 8% error rate (consisting of time ahead or behind desired time of arrival) compared to a 19% error rate in the No Tool condition. Two exploratory runs showed that similar beneficial effects can be obtained only with the CMS-D tools without scheduling takeoff times, but at the cost of a somewhat higher workload for controllers, indicating the benefits of pre-departure scheduling of aircraft with minimal delays. Hence, we found that CMS-D tools were very beneficial in the metroplex environment we tested but that further research is needed to clarify the benefits of the various scheduling approaches.

  5. Replacing natural wetlands with stormwater management facilities: Biophysical and perceived social values.

    PubMed

    Rooney, R C; Foote, L; Krogman, N; Pattison, J K; Wilson, M J; Bayley, S E

    2015-04-15

    Urban expansion replaces wetlands of natural origin with artificial stormwater management facilities. The literature suggests that efforts to mimic natural wetlands in the design of stormwater facilities can expand the provision of ecosystem services. Policy developments seek to capitalize on these improvements, encouraging developers to build stormwater wetlands in place of stormwater ponds; however, few have compared the biophysical values and social perceptions of these created wetlands to those of the natural wetlands they are replacing. We compared four types of wetlands: natural references sites, natural wetlands impacted by agriculture, created stormwater wetlands, and created stormwater ponds. We anticipated that they would exhibit a gradient in biodiversity, ecological integrity, chemical and hydrologic stress. We further anticipated that perceived values would mirror measured biophysical values. We found higher biophysical values associated with wetlands of natural origin (both reference and agriculturally impacted). The biophysical values of stormwater wetlands and stormwater ponds were lower and indistinguishable from one another. The perceived wetland values assessed by the public differed from the observed biophysical values. This has important policy implications, as the public are not likely to perceive the loss of values associated with the replacement of natural wetlands with created stormwater management facilities. We conclude that 1) agriculturally impacted wetlands provide biophysical values equivalent to those of natural wetlands, meaning that land use alone is not a great predictor of wetland value; 2) stormwater wetlands are not a substantive improvement over stormwater ponds, relative to wetlands of natural origin; 3) stormwater wetlands are poor mimics of natural wetlands, likely due to fundamental distinctions in terms of basin morphology, temporal variation in hydrology, ground water connectivity, and landscape position; 4) these drivers are relatively fixed, thus, once constructed, it may not be possible to modify them to improve provision of biophysical values; 5) these fixed drivers are not well perceived by the public and thus public perception may not capture the true value of natural wetlands, including those impacted by agriculture. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Packaging, Transportation and Recycling of NPP Condenser Modules - 12262

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Polley, G.M.

    2012-07-01

    Perma-Fix was awarded contract from Energy Northwest for the packaging, transportation and disposition of the condenser modules, water boxes and miscellaneous metal, combustibles and water generated during the 2011 condenser replacement outage at the Columbia Generating Station. The work scope was to package the water boxes and condenser modules as they were removed from the facility and transfer them to the Perma-Fix Northwest facility for processing, recycle of metals and disposition. The condenser components were oversized and overweight (the condenser modules weighed ∼102,058 kg [225,000 lb]) which required special equipment for loading and transport. Additional debris waste was packaged inmore » inter-modals and IP-1 boxes for transport. A waste management plan was developed to minimize the generation of virtually any waste requiring landfill disposal. The Perma-Fix Northwest facility was modified to accommodate the ∼15 m [50-ft] long condenser modules and equipment was designed and manufactured to complete the disassembly, decontamination and release survey. The condenser modules are currently undergoing processing for free release to a local metal recycler. Over three millions pounds of metal will be recycled and over 95% of the waste generated during this outage will not require land disposal. There were several elements of this project that needed to be addressed during the preparation for this outage and the subsequent packaging, transportation and processing. - Staffing the project to support 24/7 generation of large components and other wastes. - The design and manufacture of the soft-sided shipping containers for the condenser modules that measured ∼15 m X 4 m X 3 m [50 ft X 13 ft X 10 ft] and weighed ∼102,058 kg [225,000 lbs] - Developing a methodology for loading the modules into the shipping containers. - Obtaining a transport vehicle for the modules. - Designing and modifying the processing facility. - Movement of the modules at the processing facility. If any of these issues were not adequately resolved prior to the start of the outage, costly delays would result and the re-start of the power plant could be impacted. The main focus of this project was to find successful methods for keeping this material out of the landfills and preserving the natural resources. In addition, this operation provided a significant cost savings to the public utility by minimizing landfill disposal. The onsite portion of the project has been completed without impact to the overall outage schedule. By the date of presentation, the majority of the waste from the condenser replacement project will have been processed and recycled. The goals for this project included helping Energy Northwest maintain the outage schedule, package and characterize waste compliantly, perform transportation activities in compliance with 49CFR (Ref-1), and minimize the waste disposal volume. During this condenser replacement project, over three millions pounds of waste was generated, packaged, characterized and transported without injury or incident. It is anticipated that 95% of the waste generated during this project will not require landfill disposal. All of the waste is scheduled to be processed, decontaminated and recycled by June of 2012. (authors)« less

  7. Indicators of hearing protection use: self-report and researcher observation.

    PubMed

    Griffin, Stephanie C; Neitzel, Richard; Daniell, William E; Seixas, Noah S

    2009-10-01

    Hearing protection devices (HPD) are commonly used to prevent occupational noise-induced hearing loss. There is a large body of research on hearing protection use in industry, and much of it relies on workers' self-reported use of hearing protection. Based on previous studies in fixed industry, worker self-report has been accepted as an adequate and reliable tool to measure this behavior among workers in many industrial sectors. However, recent research indicates self-reported hearing protection use may not accurately reflect subject behavior in industries with variable noise exposure. This study compares workers' self-reported use of hearing protection with their observed use in three workplaces with two types of noise environments: one construction site and one fixed industry facility with a variable noise environment, and one fixed industry facility with a steady noise environment. Subjects reported their use of hearing protection on self-administered surveys and activity cards, which were validated using researcher observations. The primary outcome of interest in the study was the difference between the self-reported use of hearing protection in high noise on the activity card and survey: (1) over one workday, and (2) over a 2-week period. The primary hypotheses for the study were that subjects in workplaces with variable noise environments would report their use of HPDs less accurately than subjects in the stable noise environment, and that reporting would be less accurate over 2 weeks than over 1 day. In addition to noise variability, other personal and workplace factors thought to affect the accuracy of self-reported hearing protection use were also analyzed. This study found good agreement between subjects' self-reported HPD use and researcher observations. Workers in the steady noise environment self-reported hearing protection use more accurately on the surveys than workers in variable noise environments. The findings demonstrate the potential importance of noise exposure variability as a factor influencing reporting accuracy.

  8. Proceedings of the ERDC-CERL Net Zero Energy (NZE) Installation and Deployed Bases Workshop Held in Colorado Springs, CO. on 3-4 Feb 2009

    DTIC Science & Technology

    2009-06-01

    energy demand is projected to outgrow afford- able supplies even after accounting for the impact of anticipated energy efficiency and management ... management . The purpose of that change would be to facilitate development of a suite of ultra-low- energy solutions that would approach NZE usage by...enabling real-time op- timization of power supply, demand, and storage management for Army facilities, emplacements, or fixed installations of any

  9. KSC-2009-4762

    NASA Image and Video Library

    2009-08-17

    VANDENBERG AIR FORCE BASE, Calif. -- At Vandenberg Air Force Base's Astrotech processing facility in California, NASA's Wide-field Infrared Survey Explorer, or WISE, spacecraft is situated on a work stand. At right is the fixed panel solar array. The satellite will survey the entire sky at infrared wavelengths, creating a cosmic clearinghouse of hundreds of millions of objects, which will be catalogued, providing a vast storehouse of knowledge about the solar system, the Milky Way, and the universe. Launch is scheduled no earlier than Dec. 10. Photo credit: NASA/Moore, VAFB

  10. KSC-2009-4759

    NASA Image and Video Library

    2009-08-17

    VANDENBERG AIR FORCE BASE, Calif. -- At Vandenberg Air Force Base's Astrotech processing facility in California, workers secure NASA's Wide-field Infrared Survey Explorer, or WISE, spacecraft onto a work stand. At right is seen the fixed panel solar array. The satellite will survey the entire sky at infrared wavelengths, creating a cosmic clearinghouse of hundreds of millions of objects, which will be catalogued, providing a vast storehouse of knowledge about the solar system, the Milky Way, and the universe. Launch is scheduled no earlier than Dec. 10. Photo credit: NASA/Moore, VAFB

  11. KSC-2009-4761

    NASA Image and Video Library

    2009-08-17

    VANDENBERG AIR FORCE BASE, Calif. -- At Vandenberg Air Force Base's Astrotech processing facility in California, NASA's Wide-field Infrared Survey Explorer, or WISE, spacecraft is situated on a work stand. In front is the fixed panel solar array. The satellite will survey the entire sky at infrared wavelengths, creating a cosmic clearinghouse of hundreds of millions of objects, which will be catalogued, providing a vast storehouse of knowledge about the solar system, the Milky Way, and the universe. Launch is scheduled no earlier than Dec. 10. Photo credit: NASA/Moore, VAFB

  12. Systems Analysis Directorate Activities Summary, May 1976

    DTIC Science & Technology

    1976-06-01

    approach is to assume an attack by force is made on a fixed facility with the intent to remove certain materials or perform sabotage of some portion of...IBPS/»-«/, and DATA ACTL/*--/ in main program at statement numbers TAT00500-550, and move them into a BLOCK DATA subroutine as shown below: 0001...NPQ-••). The variables JJ and IIA are common variables and should not be transferred in a subroutine call statement. (7) Statement numbers 0N2211

  13. STS-44 Atlantis, OV-104, crewmembers participate in FB-SMS training at JSC

    NASA Technical Reports Server (NTRS)

    1991-01-01

    STS-44 Atlantis, Orbiter Vehicle (OV) 104, Commander Frederick D. Gregory (left) and Pilot Terence T. Henricks, positioned at their appointed stations on the forward flight deck, are joined by Mission Specialist (MS) F. Story Musgrave (center) and MS James S. Voss (standing). The crewmembers are participating in a flight simulation in the Fixed Base (FB) Shuttle Mission Simulator (SMS) located in JSC's Mission Simulation and Training Facility Bldg 5. A maze of panel switches appear overhead and in the background.

  14. STS-44 Atlantis, OV-104, crewmembers participate in JSC FB-SMS training

    NASA Technical Reports Server (NTRS)

    1991-01-01

    STS-44 Atlantis, Orbiter Vehicle (OV) 104, Commander Frederick D. Gregory and Pilot Terence T. Henricks are stationed at their appointed positions on the forward flight deck of the Fixed Base (FB) Shuttle Mission Simulator (SMS) in JSC's Mission Simulation and Training Facility Bldg 5. Gregory (left) in the commanders seat and Henricks (right) in the pilots seat look back toward aft flight deck and the photographer. Seat backs appear in the foreground and forward flight deck control panels in the background.

  15. STS-26 simulation activities in JSC Mission Control Center (MCC)

    NASA Technical Reports Server (NTRS)

    1987-01-01

    In JSC Mission Control Center (MCC) Bldg 30 Flight Control Room (FCR), flight controller Granvil A. Pennington, leaning on console, listens to communications during the STS-26 integrated simulations in progress between MCC and JSC Mission Simulation and Training Facility Bldg 5 fixed-base (FB) shuttle mission simulator (SMS). MCC FCR visual displays are seen in background. Five veteran astronauts were in the FB-SMS rehearsing their roles for the scheduled June 1988 flight aboard Discovery, Orbiter Vehicle (OV) 103.

  16. Compliance with Electrical and Fire Protection Standards of U.S. Controlled and Occupied Facilities in Afghanistan

    DTIC Science & Technology

    2013-07-18

    are subject to damage and abrasion (figure 5). The use of an extension cord instead of fixed wiring creates the possibility of fire , electrical shock...Medical Clinic has an adjacent warehouse that is of a higher hazard and is not separated by 1-hour fire resistance rated construction. KMC 17-May...higher hazard and is not separated by 1-hour fire resistance rated construction. DynCorp NO Awaiting USG Decision DI has not received governmental

  17. Managerial accounting applications in radiology.

    PubMed

    Lexa, Frank James; Mehta, Tushar; Seidmann, Abraham

    2005-03-01

    We review the core issues in managerial accounting for radiologists. We introduce the topic and then explore its application to diagnostic imaging. We define key terms such as fixed cost, variable cost, marginal cost, and marginal revenue and discuss their role in understanding the operational and financial implications for a radiology facility by using a cost-volume-profit model. Our work places particular emphasis on the role of managerial accounting in understanding service costs, as well as how it assists executive decision making.

  18. KSC-03pd1137

    NASA Image and Video Library

    2003-04-15

    KENNEDY SPACE CENTER, FLA. -- In the Payload Hazardous Servicing Facility, the lander petals of the Mars Exploration Rover 2 (MER-2) have been reopened to allow technicians access to one of the spacecraft's circuit boards. A concern arose during prelaunch testing regarding how the spacecraft interprets signals sent from its main computer to peripherals in the cruise stage, lander and small deep space transponder. The MER Mission consists of two identical rovers set to launch in June 2003. The problem will be fixed on both rovers.

  19. KSC-03pd1135

    NASA Image and Video Library

    2003-04-15

    KENNEDY SPACE CENTER, FLA. -- In the Payload Hazardous Servicing Facility, technicians reopen the lander petals of the Mars Exploration Rover 2 (MER-2) to allow access to one of the spacecraft's circuit boards. A concern arose during prelaunch testing regarding how the spacecraft interprets signals sent from its main computer to peripherals in the cruise stage, lander and small deep space transponder. The MER Mission consists of two identical rovers set to launch in June 2003. The problem will be fixed on both rovers.

  20. KSC-03pd1136

    NASA Image and Video Library

    2003-04-15

    KENNEDY SPACE CENTER, FLA. -- In the Payload Hazardous Servicing Facility, technicians reopen the lander petals of the Mars Exploration Rover 2 (MER-2) to allow access to one of the spacecraft's circuit boards. A concern arose during prelaunch testing regarding how the spacecraft interprets signals sent from its main computer to peripherals in the cruise stage, lander and small deep space transponder. The MER Mission consists of two identical rovers set to launch in June 2003. The problem will be fixed on both rovers.

  1. A Study of Emergency Room Health CAre Providers and the Fixed Facility Physical Capabilities to Manage the Presenting Radiologically Injured Patient

    DTIC Science & Technology

    1984-08-01

    large areas 6. Contaminated hair 35 a. Shampoo with mild soap for three minutes and rinse b. Monitor and repeat step a as needed c. If contamination...M counters are generally used for surveying low-level radiation and are calibrated either in counts per minute (CPM) or milloroentgens per hours (mR... surveyed for contamination? Decontaminated D. Nature of accident: Type radiation source Other Details: E. Person in charge of radiation evaluation: F

  2. Sociospatial distribution of access to facilities for moderate and vigorous intensity physical activity in Scotland by different modes of transport

    PubMed Central

    2012-01-01

    Background People living in neighbourhoods of lower socioeconomic status have been shown to have higher rates of obesity and a lower likelihood of meeting physical activity recommendations than their more affluent counterparts. This study examines the sociospatial distribution of access to facilities for moderate or vigorous intensity physical activity in Scotland and whether such access differs by the mode of transport available and by Urban Rural Classification. Methods A database of all fixed physical activity facilities was obtained from the national agency for sport in Scotland. Facilities were categorised into light, moderate and vigorous intensity activity groupings before being mapped. Transport networks were created to assess the number of each type of facility accessible from the population weighted centroid of each small area in Scotland on foot, by bicycle, by car and by bus. Multilevel modelling was used to investigate the distribution of the number of accessible facilities by small area deprivation within urban, small town and rural areas separately, adjusting for population size and local authority. Results Prior to adjustment for Urban Rural Classification and local authority, the median number of accessible facilities for moderate or vigorous intensity activity increased with increasing deprivation from the most affluent or second most affluent quintile to the most deprived for all modes of transport. However, after adjustment, the modelling results suggest that those in more affluent areas have significantly higher access to moderate and vigorous intensity facilities by car than those living in more deprived areas. Conclusions The sociospatial distributions of access to facilities for both moderate intensity and vigorous intensity physical activity were similar. However, the results suggest that those living in the most affluent neighbourhoods have poorer access to facilities of either type that can be reached on foot, by bicycle or by bus than those living in less affluent areas. This poorer access from the most affluent areas appears to be reversed for those with access to a car. PMID:22568969

  3. KSC-2013-3236

    NASA Image and Video Library

    2013-08-09

    CAPE CANAVERAL, Fla. – As seen on Google Maps, the Rotating Service Structure at Launch Complex 39A at NASA's Kennedy Space Center housed space shuttle payloads temporarily so they could be loaded inside the 60-foot-long cargo bay of a shuttle before launch. The RSS, as the structure was known, was hinged to the Fixed Service Structure on one side and rolled on a rail on the other. As its name suggests, the enclosed facility would rotate into place around the shuttle as it stood at the launch pad. Once in place, the RSS protected the shuttle and its cargo. Google precisely mapped the space center and some of its historical facilities for the company's map page. The work allows Internet users to see inside buildings at Kennedy as they were used during the space shuttle era. Photo credit: Google/Wendy Wang

  4. The NASA Lewis integrated propulsion and flight control simulator

    NASA Technical Reports Server (NTRS)

    Bright, Michelle M.; Simon, Donald L.

    1991-01-01

    A new flight simulation facility was developed at NASA-Lewis. The purpose of this flight simulator is to allow integrated propulsion control and flight control algorithm development and evaluation in real time. As a preliminary check of the simulator facility capabilities and correct integration of its components, the control design and physics models for a short take-off and vertical landing fighter aircraft model were shown, with their associated system integration and architecture, pilot vehicle interfaces, and display symbology. The initial testing and evaluation results show that this fixed based flight simulator can provide real time feedback and display of both airframe and propulsion variables for validation of integrated flight and propulsion control systems. Additionally, through the use of this flight simulator, various control design methodologies and cockpit mechanizations can be tested and evaluated in a real time environment.

  5. Private investment purchase and nursing home financial health.

    PubMed

    Orfaly Cadigan, Rebecca; Stevenson, David G; Caudry, Daryl J; Grabowski, David C

    2015-02-01

    To explore the impact of nursing home acquisition by private investment firms on nursing home costs, revenue, and overall financial health. Merged data from the Medicare Cost Reports and the Online Survey, Certification, and Reporting system for the period 1998-2010. Regression specification incorporating facility and time fixed effects. We found little impact on the financial health of nursing homes following purchase by private investment companies. However, our findings did suggest that private investment firms acquired nursing home chains in good financial health, possibly to derive profit from the company's real estate holdings. Private investment acquired facilities are an important feature of today's nursing home sector. Although we did not observe a negative impact on the financial health of nursing homes, this development raises important issues about ownership oversight and transparency for the entire nursing home sector. © Health Research and Educational Trust.

  6. Characterisation of the epithermal neutron irradiation facility at the Portuguese research reactor using MCNP.

    PubMed

    Beasley, D G; Fernandes, A C; Santos, J P; Ramos, A R; Marques, J G; King, A

    2015-05-01

    The radiation field at the epithermal beamline and irradiation chamber installed at the Portuguese Research Reactor (RPI) at the Campus Tecnológico e Nuclear of Instituto Superior Técnico was characterised in the context of Prompt Gamma Neutron Activation Analysis (PGNAA) applications. Radiographic films, activation foils and thermoluminescence dosimeters were used to measure the neutron fluence and photon dose rates in the irradiation chamber. A fixed-source MCNPX model of the beamline and chamber was developed and compared to measurements in the first step towards planning a new irradiation chamber. The high photon background from the reactor results in the saturation of the detector and the current facility configuration yields an intrinsic insensitivity to various elements of interest for PGNAA. These will be addressed in future developments. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. The use of commercial off-the-shelf equipment and its impact on C3 (Command, Control and Communications EMP (electromagnetic pulse) survivability

    NASA Astrophysics Data System (ADS)

    Hoke, Melvin D., Jr.

    1988-04-01

    The President's Blue Ribbon Commission on Defense Management has recommended that the military should make greater use of off-the-shelf components, systems, and services (also know as Non-Developmental Items or NDI). This recommendation, if blindly implemented, could have an adverse impact on the survivability of critical command, control, and communications assets. The study evaluates how the electromagnetic pulse (EMP) survivability of a strategic, time-urgent, fixed, ground-based, Command, Control, and Communications (C3) facility would be impacted by the use of off-the-shelf C3 equipments. The study concludes that to have a quantifiable measure of confidence in the facility's EMP survivability, the piece of off-the-shelf equipment under consideration will first have to be subjected to some degree of EMP testing.

  8. Performing Well on Nursing Home Report Cards: Does It Pay Off?

    PubMed Central

    Park, Jeongyoung; Konetzka, R Tamara; Werner, Rachel M

    2011-01-01

    Objective To examine whether high performance or improvement on quality measures leads to economic rewards for nursing homes in the presence of public reporting. Data Sources Data from 6,286 freestanding Medicare-certified nursing homes between 1999 and 2005 were identified in Medicare Cost Reports, Minimum Data Set, and Online Survey and Certification Reporting System. Study Design Using a facility-level fixed-effects model, the effect of public reporting on financial performance was measured by comparing each of four financial outcomes (revenues, expenses, operating, and total profit margins) before (1999–2002) to after (2003–2005) public reporting was initiated. The effects were estimated separately by level of performance and improvement over time. Principal Findings Facilities that improved on publicly reported performance had increased revenues and higher profit margins after public reporting, mainly through increased Medicare admissions. High-scoring facilities showed similar patterns, though differences were not statistically significant. Conclusions Providers that improve their performance under public reporting may receive a return on their investment in quality improvement. This supports the business case for public reporting. PMID:21029093

  9. KSC-2009-6453

    NASA Image and Video Library

    2009-11-19

    CAPE CANAVERAL, Fla. – A ceremonial "flipping of the switch" officially begins operation of NASA's first large-scale solar power generation facility at NASA's Kennedy Space Center in Florida. Flipping the four-foot-tall light switch in unison are, from left, Bob Cabana, Kennedy center director; Roderick Roche, senior manager, Project Management Office of North America, SunPower Corporation; and Eric Silagy, Florida Power & Light Company vice president and chief development officer. Representatives from NASA, Florida Power & Light Company, or FPL, and SunPower Corporation formally commissioned the one-megawatt facility and announced plans to pursue a new research, development and demonstration project at Kennedy to advance America's use of renewable energy. The facility is the first element of a major renewable energy project currently under construction at Kennedy. The completed system features a fixed-tilt, ground-mounted solar power system designed and built by SunPower, along with SunPower solar panels. A 10-megawatt solar farm, which SunPower is building on nearby Kennedy property, will supply power to FPL's customers when it is completed in April 2010. Photo credit: NASA/Jim Grossmann

  10. SHiP: a new facility with a dedicated detector for studying tau neutrino properties

    NASA Astrophysics Data System (ADS)

    Komatsu, M.; SHiP Collaboration

    2017-06-01

    SHiP (Search for Hidden Particles) is a new general purpose fixed target facility at the CERN SPS accelerator, with the aim of search for New Physics which has small coupling with standard particles by searching for long lived beyond standard model particles with masses below a few GeV/c2. The SHiP facility is a high intensity beam bump, the 400GeV proton beam extracted from the SPS will be dumped on a heavy target with the aim of integrating 2 ×1020 pot in 5 years. A dedicated detector, based on the OPERA-like ECC (Emulsion Cloud Chamber), will provide tau and anti-tau neutrino detection capability to study ντ and ν‾τ cross-sections with a statistics a few 100 times larger than the DONUT experiment. Moreover, the structure functions F4 and F5 which is only accessible by tau neutrino interactions can be measured first time. SHiP is the unique chance to study tau and anti tau neutrino properties.

  11. Simulating Extraterrestrial Ices in the Laboratory

    NASA Astrophysics Data System (ADS)

    Berisford, D. F.; Carey, E. M.; Hand, K. P.; Choukroun, M.

    2017-12-01

    Several ongoing experiments at JPL attempt to simulate the ice environment for various regimes associated with icy moons. The Europa Penitent Ice Experiment (EPIX) simulates the surface environment of an icy moon, to investigate the physics of ice surface morphology growth. This experiment features half-meter-scale cryogenic ice samples, cryogenic radiative sink environment, vacuum conditions, and diurnal cycling solar simulation. The experiment also includes several smaller fixed-geometry vacuum chambers for ice simulation at Earth-like and intermediate temperature and vacuum conditions for development of surface morphology growth scaling relations. Additionally, an ice cutting facility built on a similar platform provides qualitative data on the mechanical behavior of cryogenic ice with impurities under vacuum, and allows testing of ice cutting/sampling tools relevant for landing spacecraft. A larger cutting facility is under construction at JPL, which will provide more quantitative data and allow full-scale sampling tool tests. Another facility, the JPL Ice Physics Laboratory, features icy analog simulant preparation abilities that range icy solar system objects such as Mars, Ceres and the icy satellites of Saturn and Jupiter. In addition, the Ice Physics Lab has unique facilities for Icy Analog Tidal Simulation and Rheological Studies of Cryogenic Icy Slurries, as well as equipment to perform thermal and mechanical properties testing on icy analog materials and their response to sinusoidal tidal stresses.

  12. Malpractice Litigation and Nursing Home Quality of Care

    PubMed Central

    Konetzka, R Tamara; Park, Jeongyoung; Ellis, Robert; Abbo, Elmer

    2013-01-01

    Objective. To assess the potential deterrent effect of nursing home litigation threat on nursing home quality. Data Sources/Study Setting. We use a panel dataset of litigation claims and Nursing Home Online Survey Certification and Reporting (OSCAR) data from 1995 to 2005 in six states: Florida, Illinois, Wisconsin, New Jersey, Missouri, and Delaware, for a total of 2,245 facilities. Claims data are from Westlaw's Adverse Filings database, a proprietary legal database, on all malpractice, negligence, and personal injury/wrongful death claims filed against nursing facilities. Study Design. A lagged 2-year moving average of the county-level number of malpractice claims is used to represent the threat of litigation. We use facility fixed-effects models to examine the relationship between the threat of litigation and nursing home quality. Principal Findings. We find significant increases in registered nurse-to-total staffing ratios in response to rising malpractice threat, and a reduction in pressure sores among highly staffed facilities. However, the magnitude of the deterrence effect is small. Conclusions. Deterrence in response to the threat of malpractice litigation is unlikely to lead to widespread improvements in nursing home quality. This should be weighed against other benefits and costs of litigation to assess the net benefit of tort reform. PMID:23741985

  13. Medicaid Bed-Hold Policy and Medicare Skilled Nursing Facility Rehospitalizations

    PubMed Central

    Grabowski, David C; Feng, Zhanlian; Intrator, Orna; Mor, Vincent

    2010-01-01

    Objective To analyze the effect of states' Medicaid bed-hold policies on the 30-day rehospitalization of Medicare postacute skilled nursing facility (SNF) residents. Data Sources Minimum data set assessments were merged with Medicare claims and eligibility files for all first-time SNF admissions (N = 3,322,088) over the period 2000 through 2005; states' Medicaid bed-hold policies were obtained via survey. Study Design Regression specification incorporating facility fixed effects to examine changes in Medicaid bed-hold policies on the likelihood of a 30-day SNF rehospitalization. Principal Findings Using a continuous measure of bed-hold generosity, state Medicaid bed-hold was positively related to Medicare SNF rehospitalization. Specifically, the introduction of a bed-hold policy with average generosity increases Medicare rehospitalizations by 1.8 percent, representing roughly 12,000 SNF rehospitalizations at a cost to Medicare of approximately U.S.$100 million over our study period. Conclusions Although facilities do not receive a Medicaid bed-hold payment for Medicare SNF stays, we found that the adoption of more generous policies led to greater SNF rehospitalizations. This type of spillover is largely ignored in current discussions of Medicare payment reforms such as bundled payment. Neither Medicare nor Medicaid has an incentive to internalize the risks and benefits of its actions as they affect the other. PMID:20403059

  14. The Relationship between Costs and Quality in Veterans Health Administration Community Living Centers: An Analysis Using Longitudinal Data.

    PubMed

    Burgess, James F; Shwartz, Michael; Stolzmann, Kelly; Sullivan, Jennifer L

    2018-05-18

    To examine the relationship between cost and quality in Veterans Health Administration (VA) nursing homes (called Community Living Centers, CLCs) using longitudinal data. One hundred and thirty CLCs over 13 quarters (from FY2009 to FY2012) were studied. Costs, resident days, and resident severity (RUGs score) were obtained from the VA Managerial Cost Accounting System. Clinical quality measures were obtained from the Minimum Data Set, and resident-centered care (RCC) was measured using the Artifacts of Culture Change Tool. We used a generalized estimating equation model with facilities included as fixed effects to examine the relationship between total cost and quality after controlling for resident days and severity. The model included linear and squared terms for all independent variables and interactions with resident days. With the exception of RCC, all other variables had a statistically significant relationship with total costs. For most poorer performing smaller facilities (lower size quartile), improvements in quality were associated with higher costs. For most larger facilities, improvements in quality were associated with lower costs. The relationship between cost and quality depends on facility size and current level of performance. © Published 2018. This article is a U.S. Government work and is in the public domain in the USA.

  15. Evaluating the impact of the Baby-Friendly Hospital Initiative on breast-feeding rates: a multi-state analysis

    PubMed Central

    Hawkins, Summer Sherburne; Stern, Ariel Dora; Baum, Christopher F; Gillman, Matthew W

    2014-01-01

    Objective To evaluate the impact of the Baby-Friendly Hospital Initiative (BFHI) on breast-feeding initiation and duration overall and according to maternal education. Design Quasi-experimental study using data from five states (Alaska, Maine, Nebraska, Ohio, Washington) that participated in the Pregnancy Risk Assessment Monitoring System from 1999 to 2009. Using differences-in-differences models that included year and hospital fixed effects, we compared rates of breast-feeding initiation and duration (any and exclusive breast-feeding for ≥4 weeks) before and after BFHI accreditation between mothers who gave birth in hospitals that were accredited or became accredited and mothers from matched non-BFHI facilities. We stratified analyses into lower and higher education groups. Setting Thirteen BFHI hospitals and nineteen matched non-BFHI facilities across five states in the USA. Subjects Mothers (n 11723) who gave birth in BFHI hospitals and mothers (n 13604) from nineteen matched non-BFHI facilities. Results Although we did not find overall differences in breast-feeding initiation between birth facilities that received BFHI accreditation compared with non-Baby-Friendly facilities (adjusted coefficient = 0.024; 95 % CI −0.00, 0.51), breast-feeding initiation increased by 3.8 percentage points among mothers with lower education who delivered in Baby-Friendly facilities (P = 0.05), but not among mothers with higher education (adjusted coefficient = 0.002; 95 % CI −0.04, 0.05). BFHI accreditation also increased exclusive breast-feeding for ≥4 weeks by 4.5 percentage points (P=0.02) among mothers with lower education who delivered in BFHI facilities. Conclusions By increasing breast-feeding initiation and duration among mothers with lower education, the BFHI may reduce socio-economic disparities in breast-feeding. PMID:24625787

  16. Evaluating the impact of the Baby-Friendly Hospital Initiative on breast-feeding rates: a multi-state analysis.

    PubMed

    Hawkins, Summer Sherburne; Stern, Ariel Dora; Baum, Christopher F; Gillman, Matthew W

    2015-02-01

    To evaluate the impact of the Baby-Friendly Hospital Initiative (BFHI) on breast-feeding initiation and duration overall and according to maternal education. Quasi-experimental study using data from five states (Alaska, Maine, Nebraska, Ohio, Washington) that participated in the Pregnancy Risk Assessment Monitoring System from 1999 to 2009. Using differences-in-differences models that included year and hospital fixed effects, we compared rates of breast-feeding initiation and duration (any and exclusive breast-feeding for ≥4 weeks) before and after BFHI accreditation between mothers who gave birth in hospitals that were accredited or became accredited and mothers from matched non-BFHI facilities. We stratified analyses into lower and higher education groups. Thirteen BFHI hospitals and nineteen matched non-BFHI facilities across five states in the USA. Mothers (n 11 723) who gave birth in BFHI hospitals and mothers (n 13 604) from nineteen matched non-BFHI facilities. Although we did not find overall differences in breast-feeding initiation between birth facilities that received BFHI accreditation compared with non-Baby-Friendly facilities (adjusted coefficient = 0·024; 95 % CI -0·00, 0·51), breast-feeding initiation increased by 3·8 percentage points among mothers with lower education who delivered in Baby-Friendly facilities (P = 0·05), but not among mothers with higher education (adjusted coefficient = 0·002; 95 % CI -0·04, 0·05). BFHI accreditation also increased exclusive breast-feeding for ≥4 weeks by 4·5 percentage points (P = 0·02) among mothers with lower education who delivered in BFHI facilities. By increasing breast-feeding initiation and duration among mothers with lower education, the BFHI may reduce socio-economic disparities in breast-feeding.

  17. Use of rice-based oral rehydration solution in a large diarrhoea treatment centre in Bangladesh: in-house production, use and relative cost.

    PubMed

    Islam, M A; Mahalanabis, D; Majid, N

    1994-12-01

    Glucose-based oral rehydration salt (ORS) is an appropriate and cost-effective tool to treat diarrhoeal dehydration. In patients with a high purging rate, particularly due to cholera, rice-based ORS has been shown to substantially reduce stool output compared to glucose ORS. However, it is not used in the hospitals or diarrhoea treatment centres largely because of the non-availability of a ready-to-use inexpensive packaged product and because of the problem of cooking. In a large diarrhoea treatment centre in Bangladesh (with an annual ORS consumption of approximately 140,000 litres), we have maintained in-house production of rice ORS and used it routinely for more than 600,000 patients over the last nine years. Semi-literate health workers cook rice ORS and supervise mothers in its use. Rice ORS is less costly (US $0.15 per patient treated compared with US $0.37 for glucose ORS) and is well accepted. It is an attractive alternative to glucose ORS in many fixed facility treatment centres in countries where rice is a staple and cholera is endemic. The process of its in-house preparation and use is described in this report which may assist hospitals wishing to use rice ORS in treating diarrhoea patients. Availability of a low cost ready-to-use rice ORS packet (which needs no cooking) with adequate shelf-life will increase its use at fixed facilities.

  18. Amidine-Functionalized Poly(2-vinyl-4,4-dimethylazlactone) for Selective and Efficient CO 2 Fixing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barkakaty, Balaka; Browning, Katie L.; Sumpter, Bobby

    Development of novel polymeric materials capable of efficient CO 2 capture and separation under ambient conditions is crucial for cost-effective and practical industrial applications. Here we report the facile synthesis of a new CO 2-responsive polymer through post-polymerization modification of poly(2 vinyl-4,4-dimethylazlactone) (PVDMA). The reactive pendant azlactone groups of PVDMA are easily modified with 4-(N-methyltetrahydropyrimidine) benzyl alcohol (PBA) without any by-product formation. FTIR and TGA experiments show the new PBA functionalized polymer powder can reversibly capture CO 2 at room temperature and under atmospheric pressure. CO2 capture was selective, showing a high fixing efficiency even with a mixed gas systemmore » (20% CO 2, 80% N 2) similar to flue gas. CO 2 release occurred at room temperature and release profiles were investigated as a function of temperature. Density Functional Theory (DFT) calculations coupled with modeling and simulation reveal the presence of two CO 2 binding sites in the PBA functionalized polymer resulting in a two-step CO 2 release at room temperature. Finally, we find that the ease of material preparation, high fixing efficiency, and robust release characteristics suggest that post-polymerization modification may be a useful route to designing new materials for CO 2 capture.« less

  19. Amidine-Functionalized Poly(2-vinyl-4,4-dimethylazlactone) for Selective and Efficient CO 2 Fixing

    DOE PAGES

    Barkakaty, Balaka; Browning, Katie L.; Sumpter, Bobby; ...

    2016-02-12

    Development of novel polymeric materials capable of efficient CO 2 capture and separation under ambient conditions is crucial for cost-effective and practical industrial applications. Here we report the facile synthesis of a new CO 2-responsive polymer through post-polymerization modification of poly(2 vinyl-4,4-dimethylazlactone) (PVDMA). The reactive pendant azlactone groups of PVDMA are easily modified with 4-(N-methyltetrahydropyrimidine) benzyl alcohol (PBA) without any by-product formation. FTIR and TGA experiments show the new PBA functionalized polymer powder can reversibly capture CO 2 at room temperature and under atmospheric pressure. CO2 capture was selective, showing a high fixing efficiency even with a mixed gas systemmore » (20% CO 2, 80% N 2) similar to flue gas. CO 2 release occurred at room temperature and release profiles were investigated as a function of temperature. Density Functional Theory (DFT) calculations coupled with modeling and simulation reveal the presence of two CO 2 binding sites in the PBA functionalized polymer resulting in a two-step CO 2 release at room temperature. Finally, we find that the ease of material preparation, high fixing efficiency, and robust release characteristics suggest that post-polymerization modification may be a useful route to designing new materials for CO 2 capture.« less

  20. Cotton fiber quality characterization with light scattering and fourier transform infrared techniques.

    PubMed

    Thomasson, J A; Manickavasagam, S; Mengüç, M P

    2009-03-01

    Fiber quality measurement is critical to assessing the value of a bale of cotton for various textile purposes. An instrument that could measure numerous cotton quality properties by optical means could be made simpler and faster than current fiber quality measurement instruments, and it might be more amenable to on-line measurement at processing facilities. To that end, a laser system was used to investigate cotton fiber samples with respect to electromagnetic scattering at various wavelengths, polarization angles, and scattering angles. A Fourier transform infrared (FT-IR) instrument was also used to investigate the transmission of electromagnetic energy at various mid-infrared wavelengths. Cotton samples were selected to represent a wide range of micronaire values. Varying the wavelength of the laser at a fixed polarization resulted in little variation in scattered light among the cotton samples. However, varying the polarization at a fixed wavelength produced notable variation, indicating that polarization might be used to differentiate among cotton samples with respect to certain fiber properties. The FT-IR data in the 12 to 22 microm range produced relatively large differences in the amount of scattered light among all samples, and FT-IR data at certain combinations of fixed wavelengths were highly linearly related to certain measures of cotton quality including micronaire.

  1. Influence of temperament score and handling facility on stress, reproductive hormone concentrations, and fixed time AI pregnancy rates in beef heifers.

    PubMed

    Kasimanickam, R; Schroeder, S; Assay, M; Kasimanickam, V; Moore, D A; Gay, J M; Whittier, W D

    2014-10-01

    The objectives were (i) to evaluate the effect of temperament, determined by modified 2-point chute exit and gait score, on artificial insemination (AI) pregnancy rates in beef heifers following fixed time AI and (ii) to determine the effect of temperament on cortisol, substance-P, prolactin and progesterone at initiation of synchronization and at the time of AI. Angus beef heifers (n = 967) at eight locations were included in this study. At the initiation of synchronization (Day 0 = initiation of synchronization), all heifers received a body condition score (BCS), and temperament score (0 = calm; slow exit and walk or 1 = excitable; fast exit or jump or trot or run). Blood samples were collected from a sub-population of heifers (n = 86) at both synchronization initiation and the time of AI to determine the differences in serum progesterone, cortisol, prolactin and substance-P concentrations between temperament groups. Heifers were synchronized with 5-day CO-Synch+ controlled internal drug release (CIDR) protocol and were inseminated at 56 h after CIDR removal. Heifers were examined for pregnancy by ultrasound 70 days after AI to determine AI pregnancy. Controlling for synchronization treatment (p = 0.03), facility design (p = 0.05), and cattle handling facility design by temperament score interaction (p = 0.02), the AI pregnancy differed between heifers with excitable and calm temperament (51.9% vs 60.3%; p = 0.01). The alley-way with acute bends and turns, and long straight alley-way had lower AI pregnancy rate than did the semicircular alley-way (53.5%, 56.3% and 67.0% respectively; p = 0.05). The serum hormone concentrations differed significantly between different types of cattle handling facility (p < 0.05). The cattle handling facility design by temperament group interactions significantly influenced progesterone (p = 0.01), cortisol (p = 0.01), prolactin (p = 0.02) and substance-P (p = 0.04) both at the initiation of synchronization and at the time of AI. Inter- and intra-rater agreement for temperament scoring were moderate and good (Kappa = 0.596 ± 0.07 and 0.797 ± 0.11) respectively. The predictive value for calm and pregnant to AI was 0.87, and excited and non-pregnant to AI was 0.76. In conclusion, the modified 2-point temperament scoring method can be used to identify heifers with excitable temperament. Heifers with excitable temperament had lower AI pregnancy. Further, cattle handling facility design influenced the temperament and AI pregnancy. © 2014 Blackwell Verlag GmbH.

  2. Investigations on Two Co-C Fixed-Point Cells Prepared at INRIM and LNE-Cnam

    NASA Astrophysics Data System (ADS)

    Battuello, M.; Florio, M.; Sadli, M.; Bourson, F.

    2011-08-01

    INRIM and LNE-Cnam agreed to undertake a collaboration aimed to verify, through the use of metal-carbon eutectic fixed-point cells, methods and facilities used for defining the transition temperature of eutectic fixed points and manufacturing procedures of cells. To this purpose and as a first step of the cooperation, a Co-C cell manufactured at LNE-Cnam was measured at INRIM and compared with a local cell. The two cells were of different designs: the INRIM cell of 10 cm3 inner volume and the LNE-Cnam one of 3.9 cm3. The external dimensions of the two cells were noticeably different, namely, 40 mm in length and 24 mm in diameter for the LNE-Cnam cell 3Co4 and 110 mm in length and 42 mm in diameter for the INRIM cell. Consequently, the investigation of the effect of temperature distributions in the heating furnace was undertaken by implementing the cells inside single-zone and three-zone furnaces. The transition temperature of the cell was determined at the two institutes making use of different techniques: at INRIM radiation scales at 900 nm, 950 nm, and 1.6 μm were realized from In to Cu and then used to define T 90(Co-C) by extrapolation. At LNE-Cnam, a radiance comparator based on a grating monochromator was used for the extrapolation from the Cu fixed point. This paper presents a comparative description of the cells and the manufacturing methods and the results in terms of equivalence between the two cells and melting temperatures determined at INRIM and LNE-Cnam.

  3. Evaluating the underlying factors behind variable rate debt.

    PubMed

    McCue, Michael J; Kim, Tae Hyun Tanny

    2007-01-01

    Recent trends show a greater usage of variable rate debt among health care bond issues. In 2004, 63.4% of the total health care bonds issued were variable rate compared with 30.6% in 1995 (Fitch Ratings, 2005). The purpose of this study is to gain a better understanding of the underlying factors, credit spread, issue characteristics, and issuer factors behind why hospitals and health system borrowers select variable rate debt compared with fixed rate debt. From 2000 to 2004, this study sampled 230 newly issued tax-exempt bonds issued by acute care hospitals and health care systems that included both variable and fixed rate debt issues. Using a logistic regression model, hospitals with variable rate debt issues were assigned a value of 1, whereas hospitals with fixed rate debt issues were assigned a value of 0. This study found a positive association between bond insurance and variable rate debt and a negative association between callable feature and variable rate debt. Facilities located in certificate-of-need states that possessed higher case mix acuity, earned higher profit margins, generated higher debt service coverage, and held less debt were more likely to issue variable rate debt. Overall, hospital managers and board members of hospitals possessing a strong financial performance have an interest in utilizing variable rate debt to lower their cost of capital. In addition, this outcome may also reflect that investment bankers are doing a better job in educating senior hospital management about the interest rate savings benefit of variable rate compared with fixed rate debt.

  4. Rural-urban differences in end-of-life nursing home care: facility and environmental factors.

    PubMed

    Temkin-Greener, Helena; Zheng, Nan Tracy; Mukamel, Dana B

    2012-06-01

    This study examines urban-rural differences in end-of-life (EOL) quality of care provided to nursing home (NH) residents. We constructed 3 risk-adjusted EOL quality measures (QMs) for long-term decedent residents: in-hospital death, hospice referral before death, and presence of severe pain. We used CY2005-2007 100% Minimum Data Set, Medicare beneficiary file, and inpatient and hospice claims. Logistic regression models were estimated to predict the probability of each outcome conditional on decedents' risk factors. For each facility, QMs were calculated as the difference between the actual and the expected risk-adjusted outcome rates. We fit multivariate linear regression models, with fixed state effects, for each QM to assess the association with urban-rural location. We found urban-rural differences for in-hospital death and hospice QMs, but not for pain. Compared with NHs located in urban areas, facilities in smaller towns and in isolated rural areas have significantly (p < .001) worse EOL quality for in-hospital death and hospice use. Whereas the differences in these QMs are statistically significant between facilities located in large versus small towns, they are not statistically significant between facilities located in small towns and isolated rural areas. This study provides empirical evidence for urban-rural differences in EOL quality of care using a national sample of NHs. Identifying differences is a necessary first step toward improving care for dying NH residents and for bridging the urban-rural gap.

  5. Measuring Work Environment and Performance in Nursing Homes

    PubMed Central

    Temkin-Greener, Helena; Zheng, Nan (Tracy); Katz, Paul; Zhao, Hongwei; Mukamel, Dana B.

    2008-01-01

    Background Qualitative studies of the nursing home work environment have long suggested that such attributes as leadership and communication may be related to nursing home performance, including residents' outcomes. However, empirical studies examining these relationships have been scant. Objectives This study is designed to: develop an instrument for measuring nursing home work environment and perceived work effectiveness; test the reliability and validity of the instrument; and identify individual and facility-level factors associated with better facility performance. Research Design and Methods The analysis was based on survey responses provided by managers (N=308) and direct care workers (N=7,418) employed in 162 facilities throughout New York State. Exploratory factor analysis, Chronbach's alphas, analysis of variance, and regression models were used to assess instrument reliability and validity. Multivariate regression models, with fixed facility effects, were used to examine factors associated with work effectiveness. Results The reliability and the validity of the survey instrument for measuring work environment and perceived work effectiveness has been demonstrated. Several individual (e.g. occupation, race) and facility characteristics (e.g. management style, workplace conditions, staffing) that are significant predictors of perceived work effectiveness were identified. Conclusions The organizational performance model used in this study recognizes the multidimensionality of the work environment in nursing homes. Our findings suggest that efforts at improving work effectiveness must also be multifaceted. Empirical findings from such a line of research may provide insights for improving the quality of the work environment and ultimately the quality of residents' care. PMID:19330892

  6. Cold-welding test environment

    NASA Technical Reports Server (NTRS)

    Wang, J. T.

    1972-01-01

    A flight test was conducted and compared with ground test data. Sixteen typical spacecraft material couples were mounted on an experimental research satellite in which a motor intermittently drove the spherical moving specimens across the faces of the fixed flat specimens in an oscillating motion. Friction coefficients were measured over a period of 14-month orbital time. Surface-to-surface sliding was found to be the controlling factor of generating friction in a vacuum environment. Friction appears to be independent of passive vacuum exposure time. Prelaunch and postlaunch tests identical to the flight test were performed in an oil-diffusion-pumped ultrahigh vacuum chamber. Only 50% of the resultant data agreed with the flight data owing to pump oil contamination. Identical ground tests were run in an ultrahigh vacuum facility and a ion-pumped vacuum chamber. The agreement (90%) between data from these tests and flight data established the adequacy of these test environments and facilities.

  7. Private Investment Purchase and Nursing Home Financial Health

    PubMed Central

    Cadigan, Rebecca Orfaly; Stevenson, David G; Caudry, Daryl J; Grabowski, David C

    2015-01-01

    Objective To explore the impact of nursing home acquisition by private investment firms on nursing home costs, revenue, and overall financial health. Data Sources Merged data from the Medicare Cost Reports and the Online Survey, Certification, and Reporting system for the period 1998–2010. Study Design Regression specification incorporating facility and time fixed effects. Principal Findings We found little impact on the financial health of nursing homes following purchase by private investment companies. However, our findings did suggest that private investment firms acquired nursing home chains in good financial health, possibly to derive profit from the company’s real estate holdings. Conclusions Private investment acquired facilities are an important feature of today’s nursing home sector. Although we did not observe a negative impact on the financial health of nursing homes, this development raises important issues about ownership oversight and transparency for the entire nursing home sector. PMID:25104476

  8. Detailed results of ASTP experiment MA-011. [biological processing facility in space

    NASA Technical Reports Server (NTRS)

    Seaman, G. V. F.; Allen, R. E.; Barlow, G. H.; Bier, M.

    1976-01-01

    This experiment was developed in order to conduct engineering and operational tests of electrokinetic equipment in a micro-gravity environment. The experimental hardware in general functioned as planned and electrophoretic separations were obtained in space. The results indicated the development of satisfactory sample collection, return, and preservation techniques. The application of a near-zero zeta potential interior wall coating to the experimental columns, confirmation of biocompatibility of all appropriate hardware components, and use of a sterile operating environment provided a significant step forward in the development of a biological processing facility in space. A separation of a test of aldehyde-fixed rabbit, human, and horse red blood cells was obtained. Human kidney cells were separated into several components and viable cells returned to earth. The isotachophoretic separation of red cells was also demonstrated. Problems associated with the hardware led to a lack of success in the attempt to separate subpopulations of human lymphocytes.

  9. A concept for transition mapping on a 10 deg-cone in the National Transonic Facility using flow-pressure variation

    NASA Technical Reports Server (NTRS)

    Gartenberg, Ehud

    1995-01-01

    A conceptual study was performed to define a technique for mapping the boundary-layer transition on a 10 deg-Cone in the National Transonic Facility (NTF) as a means of determining this cryogenic-tunnel suitability for laminar flow testing. A major challenge was to devise a test matrix using a fixed surface pitot probe, varying the flow pressure to pr oduce the actual Reynolds numbers for boundary-layer transition. This constraint resulted from a lack of a suitable and reliable electrical motor to drive the probe along the cone's surface under cryogenic flow conditions. The initial phase of this research was performed by the author in collaboration with the late Dr. William B. Igoe from the Aerodynamics Division at NASA Langley Research Center. His comments made during the drafting of this document were invaluable and a source of inspiration.

  10. SHiP: a new facility to search for heavy neutrinos and study ντ properties

    NASA Astrophysics Data System (ADS)

    De Serio, M.; SHiP Collaboration

    2016-05-01

    SHiP (Search for Hidden Particles) is a newly designed fixed target facility, proposed at the CERN SPS accelerator, with the aim of complementing searches for New Physics at LHC by searching for light long-lived exotic particles with masses below a few GeV/c2. The sensitivity to Heavy Neutrinos will allow for the first time probing a region of the parameter space where Baryogenesis and active neutrino masses and oscillation could also be explained. A dedicated detector, based on OPERA-like bricks, will provide the first observation of the tau anti-neutrino. Moreover, ντ and ν¯τ cross-sections will be measured with a statistics 1000 times larger than currently available data and will allow extracting the F4 and F5 structure functions, never measured so far. Charm physics studies will be performed with significantly improved accuracy with respect to past experiments.

  11. Structural systems for deep sea terminals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rashid, A.

    1995-10-01

    This paper describes the various structural systems that can be used for loading and unloading crude oil and other by-products by small and large tankers using fixed berths. The overall facility generally consists of a long trestle supporting piping and roadway, loading and unloading platforms supporting loadings arms, metering skid, antenna towers, gangways, surge tanks, etc., breasting dolphins to absorb ships impact, mooring dolphins, and walkways. The paper examines each unit of the facility with the various structural systems applicable with their relative merits and demerits. Some of the structural systems examined are as follows: Use of multiple steel modulesmore » supported by free standing piles versus steel jackets/mini-jackets for loading platforms; Use of concrete platforms; Use of prestress concrete sections versus steel plate girders or steel trusses for trestles; Use of rubblemound causeway in lieu of a trestle in shallow waters; Use of large spare monopile dolphins versus multi-pile steel dolphins.« less

  12. Wake profile measurements of fixed and oscillating flaps

    NASA Technical Reports Server (NTRS)

    Owen, F. K.

    1984-01-01

    Although the potential of laser velocimetry for the non-intrusive measurement of complex shear flows has long been recognized, there have been few applications in other small, closely controlled laboratory situations. Measurements in large scale, high speed wind tunnels are still a complex task. To support a study of periodic flows produced by an oscillating edge flap in the Ames eleven foot wind tunnel, this study was done. The potential for laser velocimeter measurements in large scale production facilities are evaluated. The results with hot wire flow field measurements are compared.

  13. KSC-2009-4750

    NASA Image and Video Library

    2009-08-17

    VANDENBERG AIR FORCE BASE, Calif. --At Vandenberg Air Force Base's Astrotech processing facility in California, the fixed panel solar panel is seen on NASA's Wide-field Infrared Survey Explorer, or WISE, spacecraft. WISE will be moved from the travel dolly it's on to a work stand. The satellite will survey the entire sky at infrared wavelengths, creating a cosmic clearinghouse of hundreds of millions of objects, which will be catalogued, providing a vast storehouse of knowledge about the solar system, the Milky Way, and the universe. Launch is scheduled no earlier than Dec. 10. Photo credit: NASA/Moore, VAFB

  14. STS-26 long duration simulation in JSC Mission Control Center (MCC) Bldg 30

    NASA Technical Reports Server (NTRS)

    1988-01-01

    STS-26 long duration simulation is conducted in JSC Mission Control Center (MCC) Bldg 30 Flight Control Room (FCR). Front row of consoles with Propulsion Engineer (PROP) and Guidance, Navigation, and Control Systems Engineer (GNC) are visible in the foreground. CBS television camera personnel record front visual displays (orbital chart and data) for '48 Hours' program to be broadcast at a later date. The integrated simulation involved communicating with crewmembers stationed in the fixed based (FB) shuttle mission simulator (SMS) located in JSC Mission Simulation and Training Facility Bldg 5.

  15. STS-30 crewmembers train on JSC shuttle mission simulator (SMS) flight deck

    NASA Technical Reports Server (NTRS)

    1988-01-01

    Wearing headsets, Mission Specialist (MS) Mark C. Lee (left), MS Mary L. Cleave (center), and MS Norman E. Thagard pose on aft flight deck in JSC's fixed base (FB) shuttle mission simulator (SMS). In background, Commander David M. Walker and Pilot Ronald J. Grabe check data on forward flight deck CRT monitors. FB-SMS is located in JSC's Mission Simulation and Training Facility Bldg 5. Crewmembers are scheduled to fly aboard Atlantis, Orbiter Vehicle (OV) 104, in April 1989 for NASA mission STS-30.

  16. STS-26 long duration simulation in JSC Mission Control Center (MCC) Bldg 30

    NASA Technical Reports Server (NTRS)

    1988-01-01

    STS-26 long duration simulation is conducted in JSC Mission Control Center (MCC) Bldg 30 Flight Control Room (FCR). Director of Mission Operations Directorate (MOD) Eugene F. Kranz (left) and Chief of the Flight Directors Office Tommy W. Holloway monitor activity during the simulation. The two are at their normal stations on the rear row of consoles. The integrated simulation involves MCC flight controllers communicating with crewmembers stationed in the fixed based (FB) shuttle mission simulator (SMS) located in JSC Mission Simulation and Training Facility Bldg 5.

  17. STS-26 long duration simulation in JSC Mission Control Center (MCC) Bldg 30

    NASA Technical Reports Server (NTRS)

    1988-01-01

    STS-26 long duration simulation is conducted in JSC Mission Control Center (MCC) Bldg 30 Flight Control Room (FCR). CBS television camera personnel record MCC activities at Spacecraft Communicator (CAPCOM) and Flight Activities Officer (FAO) (foreground) consoles for '48 Hours' program to be broadcast at a later date. The integrated simulation involved communicating with crewmembers stationed in the fixed based (FB) shuttle mission simulator (SMS) located in JSC Mission Simulation and Training Facility Bldg 5. MCC FCR visual displays are seen in front of the rows of consoles.

  18. High throughput chemical munitions treatment system

    DOEpatents

    Haroldsen, Brent L [Manteca, CA; Stofleth, Jerome H [Albuquerque, NM; Didlake, Jr., John E.; Wu, Benjamin C-P [San Ramon, CA

    2011-11-01

    A new High-Throughput Explosive Destruction System is disclosed. The new system is comprised of two side-by-side detonation containment vessels each comprising first and second halves that feed into a single agent treatment vessel. Both detonation containment vessels further comprise a surrounding ventilation facility. Moreover, the detonation containment vessels are designed to separate into two half-shells, wherein one shell can be moved axially away from the fixed, second half for ease of access and loading. The vessels are closed by means of a surrounding, clam-shell type locking seal mechanisms.

  19. F-8C adaptive control law refinement and software development

    NASA Technical Reports Server (NTRS)

    Hartmann, G. L.; Stein, G.

    1981-01-01

    An explicit adaptive control algorithm based on maximum likelihood estimation of parameters was designed. To avoid iterative calculations, the algorithm uses parallel channels of Kalman filters operating at fixed locations in parameter space. This algorithm was implemented in NASA/DFRC's Remotely Augmented Vehicle (RAV) facility. Real-time sensor outputs (rate gyro, accelerometer, surface position) are telemetered to a ground computer which sends new gain values to an on-board system. Ground test data and flight records were used to establish design values of noise statistics and to verify the ground-based adaptive software.

  20. Methods for developing jam-resistant security communications networks at fixed-site facilities

    NASA Astrophysics Data System (ADS)

    Gangel, D. J.; Heustess, J. E.; Snell, M. K.

    Considerable work has been done identifying and developing equipment and procedures that can be used to improve the survivability of a security communications network during a jamming assault. Insight is given into alternate communications methods that can be used to develop resistance to jamming by supplementing existing radio communications. The spatial properties of jamming are then discussed and examples of how these properties can be explocited are examined. Also discussed are spread-spectrum radios that are highly resistant to jamming and the importance of jamming exercises.

  1. Recent Goddard Space Flight Center (GSFC) experience with on-orbit calibration of attitude sensors

    NASA Technical Reports Server (NTRS)

    Davis, W.; Hashmall, J.; Harman, R.

    1992-01-01

    The results of on-orbit calibration for several satellites by the flight Dynamics Facility (FDF) at GSFC are reviewed. The examples discussed include attitude calibrations for sensors, including fixed-head star trackers, fine sun sensors, three-axis magnetometers, and inertial reference units taken from recent experience with the Compton Gamma Ray observatory, the Upper Atmosphere Research Satellite, and the Extreme Ultraviolet Explorer calibration. The methods used and the results of calibration are discussed, as are the improvements attained from in-flight calibration.

  2. Note: application of a pixel-array area detector to simultaneous single crystal X-ray diffraction and X-ray absorption spectroscopy measurements.

    PubMed

    Sun, Cheng-Jun; Zhang, Bangmin; Brewe, Dale L; Chen, Jing-Sheng; Chow, G M; Venkatesan, T; Heald, Steve M

    2014-04-01

    X-ray diffraction (XRD) and X-ray absorption spectroscopy (XAS) are two main x-ray techniques in synchrotron radiation facilities. In this Note, we present an experimental setup capable of performing simultaneous XRD and XAS measurements by the application of a pixel-array area detector. For XRD, the momentum transfer in specular diffraction was measured by scanning the X-ray energy with fixed incoming and outgoing x-ray angles. By selecting a small fixed region of the detector to collect the XRD signal, the rest of the area was available for collecting the x-ray fluorescence for XAS measurements. The simultaneous measurement of XRD and X-ray absorption near edge structure for Pr0.67Sr0.33MnO3 film was demonstrated as a proof of principle for future time-resolved pump-probe measurements. A static sample makes it easy to maintain an accurate overlap of the X-ray spot and laser pump beam.

  3. Investigation of the misfueling of reciprocating piston aircraft engines

    NASA Technical Reports Server (NTRS)

    Scott, J. Holland, Jr.

    1988-01-01

    The Aircraft Misfueling Detection Project was developed by the Goddard Space Flight Center/Wallops Flight Facility at Wallops Island, Virginia. Its purpose was to investigate the misfueling of reciprocating piston aircraft engines by the inadvertent introduction of jet fuel in lieu of or as a contaminant of aviation gasoline. The final objective was the development of a device(s) that will satisfactorily detect misfueling and provide pilots with sufficient warning to avoid injury, fatality, or equipment damage. Two devices have been developed and successfully tested: one, a small contamination detection kit, for use by the pilot, and a second, more sensitive, modified gas chromatograph for use by the fixed-base operator. The gas chromatograph, in addition to providing excellent quality control of the fixed-base operator's fuel handling, is a very good backup for the detection kit in the event it produces negative results. Design parameters were developed to the extent that they may be applied easily to commercial production by the aircraft industry.

  4. Delayed unlatching mechanism

    DOEpatents

    Bzorgi, Fariborz M.

    2015-05-19

    In various embodiments an apparatus is presented for securing a structure such as a door, window, hatch, or gate that moves between an open and a closed position relative to a fixed structure to provide or deny access to a compartment, a room, an outdoor area, or a facility. Various embodiments provide a delay in opening the closure of sufficient duration to frustrate a rapid activation that might be desired by a person who is attempting to pass through the closure for some illicit purpose. Typically, hydraulics are used to activate the apparatus and no electrical energy or electronic signals are employed. In one embodiment, a plurality of actuations of a hand lever operates a hydraulic pump that moves a locking bolt from a first position in which a locking bolt is engaged with a recess in the fixed structure (preventing opening of a gate) to a second position in which the locking bolt is disengaged from the recess to permit opening of the gate.

  5. State parity laws and access to treatment for substance use disorder in the United States: implications for federal parity legislation.

    PubMed

    Wen, Hefei; Cummings, Janet R; Hockenberry, Jason M; Gaydos, Laura M; Druss, Benjamin G

    2013-12-01

    The passage of the 2008 Mental Health Parity and Addiction Equity Act and the 2010 Affordable Care Act incorporated parity for substance use disorder (SUD) treatment into federal legislation. However, prior research provides us with scant evidence as to whether federal parity legislation will hold the potential for improving access to SUD treatment. To examine the effect of state-level SUD parity laws on state-aggregate SUD treatment rates and to shed light on the impact of the recent federal SUD parity legislation. We conducted a quasi-experimental study using a 2-way (state and year) fixed-effect method. We included all known specialty SUD treatment facilities in the United States and examined treatment rates from October 1, 2000, through March 31, 2008. Our main source of data was the National Survey of Substance Abuse Treatment Services, which provides facility-level information on specialty SUD treatment. State-level SUD parity laws during the study period. State-aggregate SUD treatment rates in (1) all specialty SUD treatment facilities and (2) specialty SUD treatment facilities accepting private insurance. The implementation of any SUD parity law increased the treatment rate by 9% (P < .001) in all specialty SUD treatment facilities and by 15% (P = .02) in facilities accepting private insurance. Full parity and parity only if SUD coverage is offered increased the SUD treatment rate by 13% (P = .02) and 8% (P = .04), respectively, in all facilities and by 21% (P = .03) and 10% (P = .04), respectively, in facilities accepting private insurance. We found a positive effect of the implementation of state SUD parity legislation on access to specialty SUD treatment. Furthermore, the positive association is more pronounced in states with more comprehensive parity laws. Our findings suggest that federal parity legislation holds the potential to improve access to SUD treatment.

  6. Costs of HIV/AIDS outpatient services delivered through Zambian public health facilities.

    PubMed

    Bratt, John H; Torpey, Kwasi; Kabaso, Mushota; Gondwe, Yebo

    2011-01-01

    To present evidence on unit and total costs of outpatient HIV/AIDS services in ZPCT-supported facilities in Zambia; specifically, to measure unit costs of selected outpatient HIV/AIDS services, and to estimate total annual costs of antiretroviral therapy (ART) and prevention of mother-to-child transmission (PMTCT) in Zambia. Cost data from 2008 were collected in 12 ZPCT-supported facilities (hospitals and health centres) in four provinces. Costs of all resources used to produce ART, PMTCT and CT visits were included, using the perspective of the provider. All shared costs were distributed to clinic visits using appropriate allocation variables. Estimates of annual costs of HIV/AIDS services were made using ZPCT and Ministry of Health data on numbers of persons receiving services in 2009. Unit costs of visits were driven by costs of drugs, laboratory tests and clinical labour, while variability in visit costs across facilities was explained mainly by differences in utilization. First-year costs of ART per client ranged from US$278 to US$523 depending on drug regimen and facility type; costs of a complete course of antenatal care (ANC) including PMTCT were approximately US$114. Annual costs of ART provided in ZPCT-supported facilities were estimated at US$14.7-$40.1 million depending on regimen, and annual costs of antenatal care including PMTCT were estimated at US$16 million. In Zambia as a whole, the respective estimates were US$41.0-114.2 million for ART and US$57.7 million for ANC including PMTCT. Consistent with the literature, total costs of services were dominated by drugs, laboratory tests and clinical labour. For each visit type, variability across facilities in total costs and cost components suggests that some potential exists to reduce costs through greater harmonization of care protocols and more intensive use of fixed resources. Improving facility-level information on the costs of resources used to produce services should be emphasized as an element of health systems strengthening. © 2010 Blackwell Publishing Ltd.

  7. Analysis of resistance genes of clinical Pannonibacter phragmitetus strain 31801 by complete genome sequencing.

    PubMed

    Ming, De-Song; Chen, Qing-Qing; Chen, Xiao-Tin

    2018-05-14

    To clarify the resistance mechanisms of Pannonibacter phragmitetus 31801, isolated from the blood of a liver abscess patient, at the genomic level, we performed whole genomic sequencing using a PacBio RS II single-molecule real-time long-read sequencer. Bioinformatic analysis of the resulting sequence was then carried out to identify any possible resistance genes. Analyses included Basic Local Alignment Search Tool searches against the Antibiotic Resistance Genes Database, ResFinder analysis of the genome sequence, and Resistance Gene Identifier analysis within the Comprehensive Antibiotic Resistance Database. Prophages, clustered regularly interspaced short palindromic repeats (CRISPR), and other putative virulence factors were also identified using PHAST, CRISPRfinder, and the Virulence Factors Database, respectively. The circular chromosome and single plasmid of P. phragmitetus 31801 contained multiple antibiotic resistance genes, including those coding for three different types of β-lactamase [NPS β-lactamase (EC 3.5.2.6), β-lactamase class C, and a metal-dependent hydrolase of β-lactamase superfamily I]. In addition, genes coding for subunits of several multidrug-resistance efflux pumps were identified, including those targeting macrolides (adeJ, cmeB), tetracycline (acrB, adeAB), fluoroquinolones (acrF, ceoB), and aminoglycosides (acrD, amrB, ceoB, mexY, smeB). However, apart from the tripartite macrolide efflux pump macAB-tolC, the genome did not appear to contain the complete complement of subunit genes required for production of most of the major multidrug-resistance efflux pumps.

  8. Exploring the potential impact of an expanded genetic code on protein function

    DOE PAGES

    Xiao, Han; Nasertorabi, Fariborz; Choi, Sei -hyun; ...

    2015-05-18

    With few exceptions, all living organisms encode the same 20 canonical amino acids; however, it remains an open question whether organisms with additional amino acids beyond the common 20 might have an evolutionary advantage. In this paper, we begin to test that notion by making a large library of mutant enzymes in which 10 structurally distinct noncanonical amino acids were substituted at single sites randomly throughout TEM-1 β-lactamase. A screen for growth on the β-lactam antibiotic cephalexin afforded a unique p-acrylamido-phenylalanine (AcrF) mutation at Val-216 that leads to an increase in catalytic efficiency by increasing k cat, but not significantlymore » affecting K M. To understand the structural basis for this enhanced activity, we solved the X-ray crystal structures of the ligand-free mutant enzyme and of the deacylation-defective wild-type and mutant cephalexin acyl-enzyme intermediates. These structures show that the Val-216–AcrF mutation leads to conformational changes in key active site residues—both in the free enzyme and upon formation of the acyl-enzyme intermediate—that lower the free energy of activation of the substrate transacylation reaction. Finally, the functional changes induced by this mutation could not be reproduced by substitution of any of the 20 canonical amino acids for Val-216, indicating that an expanded genetic code may offer novel solutions to proteins as they evolve new activities.« less

  9. Secondary multidrug efflux pump mutants alter Escherichia coli biofilm growth in the presence of cationic antimicrobial compounds.

    PubMed

    Bay, Denice C; Stremick, Carol A; Slipski, Carmine J; Turner, Raymond J

    2017-04-01

    Escherichia coli possesses many secondary active multidrug resistance transporters (MDTs) that confer overlapping substrate resistance to a broad range of antimicrobials via proton and/or sodium motive force. It is uncertain whether redundant MDTs uniquely alter cell survival when cultures grow planktonically or as biofilms. In this study, the planktonic and biofilm growth and antimicrobial resistance of 13 E. coli K-12 single MDT gene deletion strains in minimal and rich media were determined. Antimicrobial tolerance to tetracycline, tobramycin and benzalkonium were also compared for each ΔMDT strain. Four E. coli MDT families were represented in this study: resistance nodulation and cell division members acrA, acrB, acrD, acrE, acrF and tolC; multidrug and toxin extruder mdtK; major facilitator superfamily emrA and emrB; and small multidrug resistance members emrE, sugE, mdtI and mdtJ. Deletions of multipartite efflux system genes acrB, acrE and tolC resulted in significant reductions in both planktonic and biofilm growth phenotypes and enhanced antimicrobial susceptibilities. The loss of remaining MDT genes produced similar or enhanced (acrD, acrE, emrA, emrB, mdtK, emrE and mdtJ) biofilm growth and antimicrobial resistance. ΔMDT strains with enhanced antimicrobial tolerance also enhanced biofilm biomass. These findings suggest that many redundant MDTs regulate biofilm formation and drug tolerance. Copyright © 2016 Institut Pasteur. Published by Elsevier Masson SAS. All rights reserved.

  10. Development of an experimental variable temperature set-up for a temperature range from 2.2 K to 325 K for cost-effective temperature sensor calibration

    NASA Astrophysics Data System (ADS)

    Pal, Sandip; Kar, Ranjan; Mandal, Anupam; Das, Ananda; Saha, Subrata

    2017-05-01

    A prototype of a variable temperature insert has been developed in-house as a cryogenic thermometer calibration facility. It was commissioned in fulfilment of the very stringent requirements of the temperature control of the cryogenic system. The calibration facility is designed for calibrating industrial cryogenic thermometers that include a temperature sensor and the wires heat-intercept in the 2.2 K-325 K temperature range. The isothermal section of the calibration block onto which the thermometers are mounted is weakly linked with the temperature control zone mounted with cooling capillary coil and cryogenic heater. The connecting wires of the thermometer are thermally anchored with the support of the temperature insert. The calibration procedure begins once the temperature of the support is stabilized. Homogeneity of the calibration block’s temperature is established both by simulation and by cross-comparison of two calibrated sensors. The absolute uncertainty present in temperature measurement is calculated and found comparable with the measured uncertainty at different temperature points. Measured data is presented in comparison to the standard thermometers at fixed points and it is possible to infer that the absolute accuracy achieved is better than  ±0.5% of the reading in comparison to the fixed point temperature. The design and development of simpler, low cost equipment, and approach to analysis of the calibration results are discussed further in this paper, so that it can be easily devised by other researchers.

  11. Design and installation of a multimode microscopy system

    NASA Astrophysics Data System (ADS)

    Helm, Johannes P.; Haug, Finn-Mogens S.; Storm, Johan F.; Ottersen, Ole-Petter

    2001-04-01

    We describe design and installation of a multi-mode microscopy core facility in an environment of varied research activity in life-sciences. The experimentators can select any combination of a) microscopes (upright, upright fixed-stage, inverted), b) microscopy modes (widefield, DIC, IRDIC, widefield epifluorescence, transmission LSM, reflection and fluorescence CLSM, MPLSM), c) imaging techniques (direct observation, video observation, photography, quantitative camera-recording, flying spot scanning), d) auxiliary systems (equipment for live specimen imaging, electrophysiology, time-coordinated laser-scanning and electrophysiology, patch-clamp). The equipment is installed on one large vibration-isolating optical table (3m X 1.5m X 0.3m). Electronics, auxiliary equipment, and a fiber-coupled, remotely controlled Ar+-Kr+ laser are mounted in a rack system fixed to the ceiling. The design of the shelves allows the head of the CSLM to be moved to any of the microscopes without increasing critical cable lengths. At the same time easy access to all the units is preserved. The beam of a Titanium-Sapphire laser, controlled by means of an EOM and a prism GVD, is coupled directly to the microscopes. Three mirrors mounted on a single precision translation table are integrated into the beam steering system so that the beam can easily be redirected to any of the microscopes. All the available instruments can be operated by the educated and trained user. The system is popular among researchers in neuroanatomy, embryology, cell biology, molecular biology - including the study of protein interactions, e.g. by means of FRET, and electrophysiology. Its colocalization with an EM facility promises to provide considerable synergy effects.

  12. Race/Ethnic Disparities in the Utilization of Treatment for Drug Dependent Inmates in U.S. State Correctional Facilities

    PubMed Central

    Nowotny, Kathryn M.

    2014-01-01

    This study examines race/ethnic disparities in treatment for drug dependent inmates in state correctional facilities. The data come from the 2004 Survey of Inmates in State Correctional Facilities. Fixed effects logistic regression is used to analyze treatment outcomes for 5,180 inmates housed within 286 prisons. The analysis accounts for differences in background characteristics (i.e., age, gender, marital status, foreign born status, veteran status), socioeconomic characteristics (i.e., education, employment prior to incarceration), mental health (i.e., diagnosis with a serious mental illness), and incarceration experiences (i.e., current conviction, previous incarceration episodes, time served, additional sentencing requirements, external social support, disciplinary violations). The findings identify a remarkable unmet need among drug dependent inmates in that less than one-half of drug dependent inmates had received any type of treatment in prison at the time of the interview with the most common treatment type being self-help groups. Compared to whites, drug dependent Latino inmates have significantly lower odds of utilizing treatment, yet there are no significant black-white disparities found. Implications for drug treatment within prisons are discussed. PMID:25270722

  13. Joint Optimization of Distribution Network Design and Two-Echelon Inventory Control with Stochastic Demand and CO2 Emission Tax Charges.

    PubMed

    Li, Shuangyan; Li, Xialian; Zhang, Dezhi; Zhou, Lingyun

    2017-01-01

    This study develops an optimization model to integrate facility location and inventory control for a three-level distribution network consisting of a supplier, multiple distribution centers (DCs), and multiple retailers. The integrated model addressed in this study simultaneously determines three types of decisions: (1) facility location (optimal number, location, and size of DCs); (2) allocation (assignment of suppliers to located DCs and retailers to located DCs, and corresponding optimal transport mode choices); and (3) inventory control decisions on order quantities, reorder points, and amount of safety stock at each retailer and opened DC. A mixed-integer programming model is presented, which considers the carbon emission taxes, multiple transport modes, stochastic demand, and replenishment lead time. The goal is to minimize the total cost, which covers the fixed costs of logistics facilities, inventory, transportation, and CO2 emission tax charges. The aforementioned optimal model was solved using commercial software LINGO 11. A numerical example is provided to illustrate the applications of the proposed model. The findings show that carbon emission taxes can significantly affect the supply chain structure, inventory level, and carbon emission reduction levels. The delay rate directly affects the replenishment decision of a retailer.

  14. Alternative Fuel Research in Fischer-Tropsch Synthesis

    NASA Technical Reports Server (NTRS)

    Surgenor, Angela D.; Klettlinger, Jennifer L.; Yen, Chia H.; Nakley, Leah M.

    2011-01-01

    NASA Glenn Research Center has recently constructed an Alternative Fuels Laboratory which is solely being used to perform Fischer-Tropsch (F-T) reactor studies, novel catalyst development and thermal stability experiments. Facility systems have demonstrated reliability and consistency for continuous and safe operations in Fischer-Tropsch synthesis. The purpose of this test facility is to conduct bench scale Fischer-Tropsch (F-T) catalyst screening experiments while focusing on reducing energy inputs, reducing CO2 emissions and increasing product yields within the F-T process. Fischer-Tropsch synthesis is considered a gas to liquid process which reacts syn-gas (a gaseous mixture of hydrogen and carbon monoxide), over the surface of a catalyst material which is then converted into liquids of various hydrocarbon chain length and product distributions1. These hydrocarbons can then be further processed into higher quality liquid fuels such as gasoline and diesel. The experiments performed in this laboratory will enable the investigation of F-T reaction kinetics to focus on newly formulated catalysts, improved process conditions and enhanced catalyst activation methods. Currently the facility has the capability of performing three simultaneous reactor screening tests, along with a fourth fixed-bed reactor used solely for cobalt catalyst activation.

  15. Energetics of muscle contraction: the whole is less than the sum of its parts

    NASA Technical Reports Server (NTRS)

    Kushmerick, M. J.; Conley, K. E.

    2002-01-01

    Understanding muscle energetics is a problem in optimizing supply of ATP to the demands of ATPases. The complexity of reactions and their fluxes to achieve this balance is greatly reduced by recognizing constraints imposed by the integration of common metabolites at fixed stoichiometry among modular units. ATPase is driven externally. Oxidative phosphorylation and glycogenolysis are the suppliers. We focus on their regulation which involves different controls, but reduces to two principles that enable facile experimental analysis of the supply and demand fluxes. The ratio of concentration of phosphocreatine (PCr) to ATP, not their individual values, sets the range of achievable concentrations of ADP in resting and active muscle (at fixed pH) in different cell types. This principle defines the fraction of available flux of oxidative phosphorylation utilized (at fixed enzyme activities). Then the kinetics of PCr recovery defines the kinetics of oxygen supply and substrate utilization. The second principle is the constancy of PCr and H(+) (lactate) production by glycogenolysis due to the coupling of ATPase and glycolysis. This principle enables glycogenolytic flux to be measured from intracellular proton loads. Further simplification occurs because the magnitude of the interacting fluxes and metabolite concentrations are specified within narrow limits when both the resting and active fluxes are quantified. Thus there is a small set of rules for assessing and understanding the thermodynamics and kinetics of muscle energetics.

  16. Hybrid Residual Flexibility/Mass-Additive Method for Structural Dynamic Testing

    NASA Technical Reports Server (NTRS)

    Tinker, M. L.

    2003-01-01

    A large fixture was designed and constructed for modal vibration testing of International Space Station elements. This fixed-base test fixture, which weighs thousands of pounds and is anchored to a massive concrete floor, initially utilized spherical bearings and pendulum mechanisms to simulate Shuttle orbiter boundary constraints for launch of the hardware. Many difficulties were encountered during a checkout test of the common module prototype structure, mainly due to undesirable friction and excessive clearances in the test-article-to-fixture interface bearings. Measured mode shapes and frequencies were not representative of orbiter-constrained modes due to the friction and clearance effects in the bearings. As a result, a major redesign effort for the interface mechanisms was undertaken. The total cost of the fixture design, construction and checkout, and redesign was over $2 million. Because of the problems experienced with fixed-base testing, alternative free-suspension methods were studied, including the residual flexibility and mass-additive approaches. Free-suspension structural dynamics test methods utilize soft elastic bungee cords and overhead frame suspension systems that are less complex and much less expensive than fixed-base systems. The cost of free-suspension fixturing is on the order of tens of thousands of dollars as opposed to millions, for large fixed-base fixturing. In addition, free-suspension test configurations are portable, allowing modal tests to be done at sites without modal test facilities. For example, a mass-additive modal test of the ASTRO-1 Shuttle payload was done at the Kennedy Space Center launch site. In this Technical Memorandum, the mass-additive and residual flexibility test methods are described in detail. A discussion of a hybrid approach that combines the best characteristics of each method follows and is the focus of the study.

  17. Constrained fixed-fulcrum reverse shoulder arthroplasty improves functional outcome in epileptic patients with recurrent shoulder instability

    PubMed Central

    Thangarajah, Tanujan; Higgs, Deborah; Bayley, J I L; Lambert, Simon M

    2016-01-01

    AIM: To report the results of fixed-fulcrum fully constrained reverse shoulder arthroplasty for the treatment of recurrent shoulder instability in patients with epilepsy. METHODS: A retrospective review was conducted at a single facility. Cases were identified using a computerized database and all clinic notes and operative reports were reviewed. All patients with epilepsy and recurrent shoulder instability were included for study. Between July 2003 and August 2011 five shoulders in five consecutive patients with epilepsy underwent fixed-fulcrum fully constrained reverse shoulder arthroplasty for recurrent anterior shoulder instability. The mean duration of epilepsy in the cohort was 21 years (range, 5-51) and all patients suffered from grand mal seizures. RESULTS: Mean age at the time of surgery was 47 years (range, 32-64). The cohort consisted of four males and one female. Mean follow-up was 4.7 years (range, 4.3-5 years). There were no further episodes of instability, and no further stabilisation or revision procedures were performed. The mean Oxford shoulder instability score improved from 8 preoperatively (range, 5-15) to 30 postoperatively (range, 16-37) (P = 0.015) and the mean subjective shoulder value improved from 20 (range, 0-50) preoperatively to 60 (range, 50-70) postoperatively (P = 0.016). Mean active forward elevation improved from 71° preoperatively (range, 45°-130°) to 100° postoperatively (range, 80°-90°) and mean active external rotation improved from 15° preoperatively (range, 0°-30°) to 40° (20°-70°) postoperatively. No cases of scapular notching or loosening were noted. CONCLUSION: Fixed-fulcrum fully constrained reverse shoulder arthroplasty should be considered for the treatment of recurrent shoulder instability in patients with epilepsy. PMID:27458554

  18. Time Series Analysis for Forecasting Hospital Census: Application to the Neonatal Intensive Care Unit

    PubMed Central

    Hoover, Stephen; Jackson, Eric V.; Paul, David; Locke, Robert

    2016-01-01

    Summary Background Accurate prediction of future patient census in hospital units is essential for patient safety, health outcomes, and resource planning. Forecasting census in the Neonatal Intensive Care Unit (NICU) is particularly challenging due to limited ability to control the census and clinical trajectories. The fixed average census approach, using average census from previous year, is a forecasting alternative used in clinical practice, but has limitations due to census variations. Objective Our objectives are to: (i) analyze the daily NICU census at a single health care facility and develop census forecasting models, (ii) explore models with and without patient data characteristics obtained at the time of admission, and (iii) evaluate accuracy of the models compared with the fixed average census approach. Methods We used five years of retrospective daily NICU census data for model development (January 2008 – December 2012, N=1827 observations) and one year of data for validation (January – December 2013, N=365 observations). Best-fitting models of ARIMA and linear regression were applied to various 7-day prediction periods and compared using error statistics. Results The census showed a slightly increasing linear trend. Best fitting models included a non-seasonal model, ARIMA(1,0,0), seasonal ARIMA models, ARIMA(1,0,0)x(1,1,2)7 and ARIMA(2,1,4)x(1,1,2)14, as well as a seasonal linear regression model. Proposed forecasting models resulted on average in 36.49% improvement in forecasting accuracy compared with the fixed average census approach. Conclusions Time series models provide higher prediction accuracy under different census conditions compared with the fixed average census approach. Presented methodology is easily applicable in clinical practice, can be generalized to other care settings, support short- and long-term census forecasting, and inform staff resource planning. PMID:27437040

  19. Time Series Analysis for Forecasting Hospital Census: Application to the Neonatal Intensive Care Unit.

    PubMed

    Capan, Muge; Hoover, Stephen; Jackson, Eric V; Paul, David; Locke, Robert

    2016-01-01

    Accurate prediction of future patient census in hospital units is essential for patient safety, health outcomes, and resource planning. Forecasting census in the Neonatal Intensive Care Unit (NICU) is particularly challenging due to limited ability to control the census and clinical trajectories. The fixed average census approach, using average census from previous year, is a forecasting alternative used in clinical practice, but has limitations due to census variations. Our objectives are to: (i) analyze the daily NICU census at a single health care facility and develop census forecasting models, (ii) explore models with and without patient data characteristics obtained at the time of admission, and (iii) evaluate accuracy of the models compared with the fixed average census approach. We used five years of retrospective daily NICU census data for model development (January 2008 - December 2012, N=1827 observations) and one year of data for validation (January - December 2013, N=365 observations). Best-fitting models of ARIMA and linear regression were applied to various 7-day prediction periods and compared using error statistics. The census showed a slightly increasing linear trend. Best fitting models included a non-seasonal model, ARIMA(1,0,0), seasonal ARIMA models, ARIMA(1,0,0)x(1,1,2)7 and ARIMA(2,1,4)x(1,1,2)14, as well as a seasonal linear regression model. Proposed forecasting models resulted on average in 36.49% improvement in forecasting accuracy compared with the fixed average census approach. Time series models provide higher prediction accuracy under different census conditions compared with the fixed average census approach. Presented methodology is easily applicable in clinical practice, can be generalized to other care settings, support short- and long-term census forecasting, and inform staff resource planning.

  20. Arcjet Flow Properties Determined from Laser-Induced Fluorescence of Atomic Species

    NASA Technical Reports Server (NTRS)

    Fletcher, Douglas G.

    1997-01-01

    Flow property measurements that were recently acquired in the Ames Research Center Aerodynamic Heating Facility (AHF) arc jet using two-photon Laser-Induced Fluorescence (LIF) of atomic nitrogen and oxygen are reported. The measured properties, which include velocity, translational temperature, and species concentration, cover a wide range of facility operation for the 30 cm nozzle. During the tests, the arc jet pressure and input stream composition were maintained at fixed values and the arc current was varied to vary the flow enthalpy. As part of this ongoing effort, a measurement of the two-photon absorption coefficient for the 3p4D<-2p4S transition of atomic nitrogen was performed, and the measured value is used to convert the relative concentration measurements to absolute values. A flow reactor is used to provide a known temperature line shape profile to deconvolve the laser line width contribution to the translational temperature measurements. Results from the current experiments are compared with previous results obtained using NO-Beta line profiles at room temperature and the problem of multimode laser oscillation and its impact on the two-photon excitation line shape are discussed. One figure is attached, and this figure shows relative N atom concentration measurements as a function of the arc power. Other measurements have already been acquired and analyzed. This poster represents an application of laser-spectroscopic measurements in an important test facility. The arc jet flow facilities are heavily used in thermal protection material development and evaluation. All hypersonic flight and planetary atmospheric entry vehicles will use materials tested in these arc jet facilities.

  1. The impact of Medicaid payer status on hospitalizations in nursing homes

    PubMed Central

    Cai, Shubing; Miller, Susan C.; Nelson, Dallas L.; Mukamel, Dana B.

    2015-01-01

    Objectives To examine the association between payer status (Medicaid versus private-pay) and the risk of hospitalizations among long-term stay nursing home (NH) residents who reside in the same facility. Data and study population The 2007–2010 national Medicare Claims and the Minimum Data Set were linked. We identified newly admitted NH residents who became long-stayers and then followed them for 180 days. Analyses Three dichotomous outcomes – all-cause, discretionary and nondiscretionary hospitalizations during the follow-up period – were defined. Linear probability model with facility fixed-effects and robust standard errors were used to examine the within-facility difference in hospitalizations between Medicaid and private-pay residents. A set of sensitivity analyses were performed to examine the robustness of the findings. Results The prevalence of all-cause hospitalization during a 180-day follow-up period was 23.3% among Medicaid residents compared to 21.6% among private-pay residents. After accounting for individual characteristics and facility effects, the probability of any all-cause hospitalization was 1.8 percentage point (P<0.01) higher for Medicaid residents than for private-pay residents within the same facility. We also found Medicaid residents were more likely to be hospitalized for discretionary conditions (5% increase in the likelihood of discretionary hospitalizations), but not for non-discretionary conditions. The findings from the sensitivity analyses were consistent with the main analyses. Conclusion Observed higher hospitalization rates for Medicaid NH residents are at least in part driven by the financial incentive NHs have to hospitalize Medicaid residents. PMID:26067881

  2. Associations between access to recreational physical activity facilities and body mass index in Scottish adults.

    PubMed

    Ellaway, Anne; Lamb, Karen E; Ferguson, Neil S; Ogilvie, David

    2016-08-09

    The aim of this country-wide study was to link individual health and behavioural data with area-level spatial data to examine whether the body mass index (BMI) of adults was associated with access to recreational physical activity (PA) facilities by different modes of transport (bus, car, walking, cycling) and the extent to which any associations were mediated by PA participation. Data on individual objectively-measured BMI, PA (number of days of (a) ≥20 min of moderate-to-vigorous PA, and (b) ≥15 min of sport or exercise, in previous 4 weeks), and socio-demographic characteristics were obtained from a nationally representative sample of 6365 adults. The number of accessible PA facilities per 1,000 individuals in each small area (data zones) was obtained by mapping a representative list of all fixed PA facilities throughout mainland Scotland. A novel transport network was developed for the whole country, and routes on foot, by bike, by car and by bus from the weighted population centroid of each data zone to each facility were calculated. Separate multilevel models were fitted to examine associations between BMI and each of the 24 measures of accessibility of PA facilities and BMI, adjusting for age, gender, longstanding illness, car availability, social class, dietary quality and urban/rural classification. We found associations (p < 0.05) between BMI and 7 of the 24 accessibility measures, with mean BMI decreasing with increasing accessibility of facilities-for example, an estimated decrease of 0.015 BMI units per additional facility within a 20-min walk (p = 0.02). None of these accessibility measures were found to be associated with PA participation. Our national study has shown that some measures of the accessibility of PA facilities by different modes of transport (particularly by walking and cycling) were associated with BMI; but PA participation, as measured here, did not appear to play a part in this relationship. Understanding the multi-factorial environmental influences upon obesity is key to developing effective interventions to reduce it.

  3. Addendum to Sampling and Analysis Plan (SAP) for Assessment of LANL-Derived Residual Radionuclides in Soils within Tract A-16-d for Land Conveyance and Transfer for Sewage Treatment Facility Area

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Whicker, Jeffrey Jay; Gillis, Jessica Mcdonnel; Ruedig, Elizabeth

    This report summarizes the sampling design used, associated statistical assumptions, as well as general guidelines for conducting post-sampling data analysis. Sampling plan components presented here include how many sampling locations to choose and where within the sampling area to collect those samples. The type of medium to sample (i.e., soil, groundwater, etc.) and how to analyze the samples (in-situ, fixed laboratory, etc.) are addressed in other sections of the sampling plan.

  4. The informatics of health care reform.

    PubMed Central

    Masys, D R

    1996-01-01

    Health care in the United States has entered a period of economic upheaval. Episodic, fee-for-service care financed by indemnity insurance is being replaced by managed care financed by fixed-price, capitated health plans. The resulting focus on reducing costs, especially in areas where there is competition fueled by oversupply of health services providers and facilities, poses new threats to the livelihood of medical libraries and medical librarians but also offers new opportunities. Internet services, consumer health education, and health services research will grow in importance, and organizational mergers will provide librarians with opportunities to assume new roles within their organizations. PMID:8938325

  5. STS-57 crewmembers train in JSC's FB Shuttle Mission Simulator (SMS)

    NASA Technical Reports Server (NTRS)

    1993-01-01

    STS-57 Endeavour, Orbiter Vehicle (OV) 105, Mission Specialist 2 (MS2) Nancy J. Sherlock, holding computer diskettes and procedural checklist, discusses equipment operation with Commander Ronald J. Grabe on the middeck of JSC's fixed based (FB) shuttle mission simulator (SMS). Payload Commander (PLC) G. David Low points to a forward locker location as MS3 Peter J.K. Wisoff switches controls on overhead panels MO42F and MO58F, and MS4 Janice E. Voss looks on. The FB-SMS is located in the Mission Simulation and Training Facility Bldg 5.

  6. KSC-2009-4760

    NASA Image and Video Library

    2009-08-17

    VANDENBERG AIR FORCE BASE, Calif. -- At Vandenberg Air Force Base's Astrotech processing facility in California, NASA's Wide-field Infrared Survey Explorer, or WISE, spacecraft is situated on a work stand. At left on the spacecraft is the fixed panel solar array. In front, the square is the HGA Slotted Array (Ku-Band). The satellite will survey the entire sky at infrared wavelengths, creating a cosmic clearinghouse of hundreds of millions of objects, which will be catalogued, providing a vast storehouse of knowledge about the solar system, the Milky Way, and the universe. Launch is scheduled no earlier than Dec. 10. Photo credit: NASA/Moore, VAFB

  7. STS-31 crewmembers during simulation on the flight deck of JSC's FB-SMS

    NASA Technical Reports Server (NTRS)

    1988-01-01

    On the flight deck of JSC's fixed based (FB) shuttle mission simulator (SMS), Mission Specialist (MS) Steven A. Hawley (left), on aft flight deck, looks over the shoulders of Commander Loren J. Shriver, seated at the commanders station (left) and Pilot Charles F. Bolden, seated at the pilots station and partially blocked by the seat's headrest (right). The three astronauts recently named to the STS-31 mission aboard Discovery, Orbiter Vehicle (OV) 103, go through a procedures checkout in the FB-SMS. The training simulation took place in JSC's Mission Simulation and Training Facility Bldg 5.

  8. STS-44 Atlantis, OV-104, crewmembers participate in FB-SMS training at JSC

    NASA Image and Video Library

    1991-04-22

    S91-35303 (22 April 1991) --- Astronauts Frederick D. Gregory (left) and Terrence T. Henricks (right), STS-44 commander and pilot, respectively, are joined near their launch and entry stations by F. Story Musgrave, mission specialist. The three pause while rehearsing some of the activities that will be performed during the scheduled ten-day November flight. Musgrave will be in a rear cabin station during launch and entry phases of the flight deck of the fixed-base Shuttle Mission Simulator (SMS) in the Johnson Space Center's mission simulation and training facility.

  9. STS-36 Commander Creighton and Pilot Casper on flight deck during JSC training

    NASA Technical Reports Server (NTRS)

    1989-01-01

    In their forward flight deck stations, STS-36 Commander John O. Creighton and Pilot John H. Casper discuss procedures prior to participating in JSC Fixed Based (FB) Shuttle Mission Simulator (SMS) exercises in the Shuttle Simulation and Training Facility Bldg 5. Creighton (left) sits in front of the commanders station controls and Casper (right) in front of the pilots station controls. Checklists are posted in various positions on the forward control panels as the crewmembers prepare for the FB-SMS simulation and their Department of Defense (DOD) flight aboard Atlantis, Orbiter Vehicle (OV) 104.

  10. JSC Shuttle Mission Simulator (SMS) visual system payload bay video image

    NASA Technical Reports Server (NTRS)

    1981-01-01

    This video image is of the STS-2 Columbia, Orbiter Vehicle (OV) 102, payload bay (PLB) showing the Office of Space Terrestrial Applications 1 (OSTA-1) pallet (Shuttle Imaging Radar A (SIR-A) antenna (left) and SIR-A recorder, Shuttle Multispectral Infrared Radiometer (SMIRR), Feature Identification Location Experiment (FILE), Measurement of Air Pollution for Satellites (MAPS) (right)). The image is used in JSC's Fixed Based (FB) Shuttle Mission Simulator (SMS). It is projected inside the FB-SMS crew compartment during mission simulation training. The FB-SMS is located in the Mission Simulation and Training Facility Bldg 5.

  11. An energy- and resource-saving technology for utilizing the sludge from thermal power station water treatment facilities

    NASA Astrophysics Data System (ADS)

    Nikolaeva, L. A.; Khusaenova, A. Z.

    2014-05-01

    A method for utilizing production wastes is considered, and a process circuit arrangement is proposed for utilizing a mixture of activated silt and sludge from chemical water treatment by incinerating it with possible heat recovery. The sorption capacity of the products from combusting a mixture of activated silt and sludge with respect to gaseous emissions is experimentally determined. A periodic-duty adsorber charged with a fixed bed of sludge is calculated, and the heat-recovery boiler efficiency is estimated together with the technical-economic indicators of the proposed utilization process circuit arrangement.

  12. Facile fabrication of luminescent organic dots by thermolysis of citric acid in urea melt, and their use for cell staining and polyelectrolyte microcapsule labelling.

    PubMed

    Zholobak, Nadezhda M; Popov, Anton L; Shcherbakov, Alexander B; Popova, Nelly R; Guzyk, Mykhailo M; Antonovich, Valeriy P; Yegorova, Alla V; Scrypynets, Yuliya V; Leonenko, Inna I; Baranchikov, Alexander Ye; Ivanov, Vladimir K

    2016-01-01

    Luminescent organic dots (O-dots) were synthesized via a one-pot, solvent-free thermolysis of citric acid in urea melt. The influence of the ratio of the precursors and the duration of the process on the properties of the O-dots was established and a mechanism of their formation was hypothesized. The multicolour luminescence tunability and toxicity of synthesized O-dots were extensively studied. The possible applications of O-dots for alive/fixed cell staining and labelling of layer-by-layer polyelectrolyte microcapsules were evaluated.

  13. Local Medicaid Home- and Community-Based Services Spending and Nursing Home Admissions of Younger Adults

    PubMed Central

    Keohane, Laura; Mor, Vincent

    2014-01-01

    We used fixed-effect models to examine the relationship between local spending on home- and community-based services (HCBSs) for cash-assisted Medicaid-only disabled (CAMOD) adults and younger adult admissions to nursing homes in the United States during 2001 through 2008, with control for facility and market characteristics and secular trends. We found that increased CAMOD Medicaid HCBS spending at the local level is associated with decreased admissions of younger adults to nursing homes. Our findings suggest that states’ efforts to expand HCBS for this population should continue. PMID:25211711

  14. Local Medicaid home- and community-based services spending and nursing home admissions of younger adults.

    PubMed

    Thomas, Kali S; Keohane, Laura; Mor, Vincent

    2014-11-01

    We used fixed-effect models to examine the relationship between local spending on home- and community-based services (HCBSs) for cash-assisted Medicaid-only disabled (CAMOD) adults and younger adult admissions to nursing homes in the United States during 2001 through 2008, with control for facility and market characteristics and secular trends. We found that increased CAMOD Medicaid HCBS spending at the local level is associated with decreased admissions of younger adults to nursing homes. Our findings suggest that states' efforts to expand HCBS for this population should continue.

  15. CHILD CARE AVAILABILITY AND FIRST-BIRTH TIMING IN NORWAY*

    PubMed Central

    Rindfuss, Ronald R.; Guilkey, David; Morgan, S. Philip; Kravdal, Øystein; Guzzo, Karen Benjamin

    2010-01-01

    Both sociological and economic theories posit that widely available, high-quality, and affordable child care should have pronatalist effects. Yet to date, the empirical evidence has not consistently supported this hypothesis. We argue that this previous empirical work has been plagued by the inability to control for endogenous placement of day care centers and the possibility that people migrate to take advantage of the availability of child care facilities. Using Norwegian register data and a statistically defensible fixed-effects model, we find strong positive effects of day care availability on the transition to motherhood. PMID:17583309

  16. Live Imaging of Shoot Meristems on an Inverted Confocal Microscope Using an Objective Lens Inverter Attachment

    PubMed Central

    Nimchuk, Zachary L.; Perdue, Tony D.

    2017-01-01

    Live imaging of above ground meristems can lead to new insights in plant development not possible from static imaging of fixed tissue. The use of an upright confocal microscope offers several technical and biological advantages for live imaging floral or shoot meristems. However, many departments and core facilities possess only inverted confocal microscopes and lack the funding for an additional upright confocal microscope. Here we show that imaging of living apical meristems can be performed on existing inverted confocal microscopes with the use of an affordable and detachable InverterScope accessory. PMID:28579995

  17. STS-104 Crew Training Clips

    NASA Technical Reports Server (NTRS)

    2001-01-01

    The crewmembers of STS-104, Commander Steven Lindsey, Pilot Charles Hobaugh, and Mission Specialists Michael Gernhardt, James Reilly, and Janet Kavandi, are seen during various stages of their training. Footage shows the following: (1) Water Survival Training at the Neutral Buoyancy Laboratory (NBL); (2) Rendezvous and Docking Training in the Shuttle Mission Simulator; (3) Training in the Space Station Airlock; (4) Training in the Virtual Reality Lab; (5) Post-insertion Operations in the Fixed Base Simulator; (6) Extravehicular Activity Training at the NBL; (7) Crew Stowage Training in the Space Station Mock-up Training Facility; and (8) Water Transfer Training in the Crew Compartment Trainer.

  18. Facile fabrication of luminescent organic dots by thermolysis of citric acid in urea melt, and their use for cell staining and polyelectrolyte microcapsule labelling

    PubMed Central

    Zholobak, Nadezhda M; Popov, Anton L; Shcherbakov, Alexander B; Popova, Nelly R; Guzyk, Mykhailo M; Antonovich, Valeriy P; Yegorova, Alla V; Scrypynets, Yuliya V; Leonenko, Inna I; Baranchikov, Alexander Ye

    2016-01-01

    Luminescent organic dots (O-dots) were synthesized via a one-pot, solvent-free thermolysis of citric acid in urea melt. The influence of the ratio of the precursors and the duration of the process on the properties of the O-dots was established and a mechanism of their formation was hypothesized. The multicolour luminescence tunability and toxicity of synthesized O-dots were extensively studied. The possible applications of O-dots for alive/fixed cell staining and labelling of layer-by-layer polyelectrolyte microcapsules were evaluated. PMID:28144539

  19. Live Imaging of Shoot Meristems on an Inverted Confocal Microscope Using an Objective Lens Inverter Attachment.

    PubMed

    Nimchuk, Zachary L; Perdue, Tony D

    2017-01-01

    Live imaging of above ground meristems can lead to new insights in plant development not possible from static imaging of fixed tissue. The use of an upright confocal microscope offers several technical and biological advantages for live imaging floral or shoot meristems. However, many departments and core facilities possess only inverted confocal microscopes and lack the funding for an additional upright confocal microscope. Here we show that imaging of living apical meristems can be performed on existing inverted confocal microscopes with the use of an affordable and detachable InverterScope accessory.

  20. A Method for Efficient Searching at Online Shopping

    NASA Astrophysics Data System (ADS)

    Sanjo, Tomomi; Nagata, Moiro

    In recent years, online shopping has been popularized. However, the users can not find efficiently their items at on-line markets. This paper proposes an engine to find items easily at the online market. This engine has the following facilities. First, it presents information in a fixed format. Second, the user can find items by selected keywords. Third, it presents only necessary information by using his/her history. Finally, it has a customize function for each user. Moreover, the system asks the users to down load a page of recommended items. We show the effectives of our proposal with some experiments.

  1. Assessment of personal airborne exposures and surface contamination from x-ray vaporization of beryllium targets at the National Ignition Facility.

    PubMed

    Paik, Samuel Y; Epperson, Patrick M; Kasper, Kenneth M

    2017-06-01

    This article presents air and surface sampling data collected over the first two years since beryllium was introduced as a target material at the National Ignition Facility. Over this time, 101 experiments with beryllium-containing targets were executed. The data provides an assessment of current conditions in the facility and a baseline for future impacts as new, reduced regulatory limits for beryllium are being proposed by both the Occupational Safety and Health Administration and Department of Energy. This study also investigates how beryllium deposits onto exposed surfaces as a result of x-ray vaporization and the effectiveness of simple decontamination measures in reducing the amount of removable beryllium from a surface. Based on 1,961 surface wipe samples collected from entrant components (equipment directly exposed to target debris) and their surrounding work areas during routine reconfiguration activities, only one result was above the beryllium release limit of 0.2 µg/100 cm 2 and 27 results were above the analytical reporting limit of 0.01 µg/100 cm 2 , for a beryllium detection rate of 1.4%. Surface wipe samples collected from the internal walls of the NIF target chamber, however, showed higher levels of beryllium, with beryllium detected on 73% and 87% of the samples during the first and second target chamber entries (performed annually), respectively, with 23% of the samples above the beryllium release limit during the second target chamber entry. The analysis of a target chamber wall panel exposed during the first 30 beryllium-containing experiments (cumulatively) indicated that 87% of the beryllium contamination remains fixed onto the surface after wet wiping the surface and 92% of the non-fixed contamination was removed by decontaminating the surface using a dry wipe followed by a wet wipe. Personal airborne exposures assessed during access to entrant components and during target chamber entry indicated that airborne beryllium was not present in workers' breathing zones. All the data thus far have shown that beryllium has been effectively managed to prevent exposures to workers during routine and non-routine work.

  2. Assessment of personal airborne exposures and surface contamination from x-ray vaporization of beryllium targets at the National Ignition Facility

    DOE PAGES

    Paik, Samuel Y.; Epperson, Patrick M.; Kasper, Kenneth M.

    2017-02-28

    Here, this article presents air and surface sampling data collected over the first two years since beryllium was introduced as a target material at the National Ignition Facility. Over this time, 101 experiments with beryllium-containing targets were executed. The data provides an assessment of current conditions in the facility and a baseline for future impacts as new, reduced regulatory limits for beryllium are being proposed by both the Occupational Safety and Health Administration and Department of Energy. This study also investigates how beryllium deposits onto exposed surfaces as a result of x-ray vaporization and the effectiveness of simple decontamination measuresmore » in reducing the amount of removable beryllium from a surface. Based on 1,961 surface wipe samples collected from entrant components (equipment directly exposed to target debris) and their surrounding work areas during routine reconfiguration activities, only one result was above the beryllium release limit of 0.2 µg/100 cm 2 and 27 results were above the analytical reporting limit of 0.01 µg/100 cm 2, for a beryllium detection rate of 1.4%. Surface wipe samples collected from the internal walls of the NIF target chamber, however, showed higher levels of beryllium, with beryllium detected on 73% and 87% of the samples during the first and second target chamber entries (performed annually), respectively, with 23% of the samples above the beryllium release limit during the second target chamber entry. The analysis of a target chamber wall panel exposed during the first 30 beryllium-containing experiments (cumulatively) indicated that 87% of the beryllium contamination remains fixed onto the surface after wet wiping the surface and 92% of the non-fixed contamination was removed by decontaminating the surface using a dry wipe followed by a wet wipe. Personal airborne exposures assessed during access to entrant components and during target chamber entry indicated that airborne beryllium was not present in workers' breathing zones. Finally, all the data thus far have shown that beryllium has been effectively managed to prevent exposures to workers during routine and non-routine work.« less

  3. An International Intercomparison of Argon Triple Point Calibration Facilities, Accommodating Long-stem Thermometers

    NASA Astrophysics Data System (ADS)

    Bloembergen, P.; Bonnier, G.; Ronsin, H.

    1990-01-01

    Argon triple point calibration facilities have been compared among eight laboratories with one transfer system, employing local long-stem standard platinum resistance thermometers. The apparatus intercompared, included a sealed cell and its associated cryostat. As is evidenced by the results of long-term investigations, previously performed at the INM, cells of the type employed may show a triple-point temperature, which is stable within the reproducibility of the measurements (simeq0,1 mK) over a period of about 10 years. At each laboratory the mean difference between the Argon triple-point temperature of the transfer cell (t) and the local cell (i) has been determined, using a standard resistance thermometer previously calibrated at the fixed points, according to the IPTS-68; associated repeatabilities are typically of the order of 0,1 mK. The reproducibility attained by measuring the mean difference in different laboratories, using cells of the same type and origin (INM), amounts to 0,4 mK.

  4. Updates on HRF Payloads Operations in Columbus ATCS

    NASA Technical Reports Server (NTRS)

    DePalo, Savino; Wright, Bruce D.; La,e Robert E.; Challis, Simon; Davenport, Robert; Pietrafesa, Donata

    2011-01-01

    The NASA developed Human Research Facility 1 (HRF1) and Human Research Facility (HRF2) experiment racks have been operating in the European Space Agency (ESA) Columbus module of the International Space Station (ISS) since Summer 2008. The two racks are of the same design. Since the start of operations, unexpected pressure spikes were observed in the Columbus module's thermal-hydraulic system during the racks activation sequence. The root cause of these spikes was identified in the activation command sequence in the Rack Interface Controller (RIC), which controls the flow of thermal-hydraulic system fluid through the rack. A new Common RIC Software (CRS) release fixed the bug and was uploaded on both racks in late 2009. This paper gives a short introduction to the topic, describes the Columbus module countermeasures to mitigate the spikes, describes the ground validation test of the new software, and describes the flight checks performed before and after the final upload. Finally, the new on-orbit test designed to further simplify the racks hydraulic management is presented.

  5. Investigation of Aerodynamics Scale Effects for a Generic Fighter Configuration in the National Transonic Facility (Invited)

    NASA Technical Reports Server (NTRS)

    Tomek, W. G.; Wahls, R. A.; Owens, L. R.; Burner, A. B.; Graves, S. S.; Luckring, J. M.

    2003-01-01

    Two wind tunnel tests of a generic fighter configuration have been completed in the National Transonic Facility. The primary purpose of the tests was to assess Reynolds number scale effects on a thin-wing, fighter-type configuration up to full-scale flight conditions (that is, Reynolds numbers of the order of 60 million). The tests included longitudinal and lateral/directional studies at subsonic and transonic conditions across a range of Reynolds numbers from that available in conventional wind tunnels to flight conditions. Results are presented for three Mach numbers (0.6, 0.8, and 0.9) and three configurations: 1) Fuselage / Wing, 2) Fuselage / Wing / Centerline Vertical Tail / Horizontal Tail, and 3) Fuselage / Wing / Trailing-Edge Extension / Twin Vertical Tails. Reynolds number effects on the lateral-directional aerodynamic characteristics are presented herein, along with longitudinal data demonstrating the effects of fixing the boundary layer transition location for low Reynolds number conditions. In addition, an improved model videogrammetry system and results are discussed.

  6. Shock tunnel studies of scramjet phenomena 1994

    NASA Technical Reports Server (NTRS)

    1995-01-01

    A new expansion tube facility has been built, and is in the process of being commissioned. It has a bore of 90 mm, and has been designed for peak rupture pressures of 100 Mpa. It is configured with multiple sections and diaphragm location stations to give optimized performance over a range of sub and superorbital conditions. It has a compound piston arrangement for a two stage compression, designed to maximize the length of shock expansion tube which can be driven within a fixed total facility length. Experiments have been successfully performed with a dummy first stage piston, and a rubber energy absorbing brake. The results agree well with a one-dimensional stress wave model of the piston impacting on the rubber, and codes for piston motion. Strain of the rubber is restricted to approximately 20 percent at which level no damage is to be expected in the buffer material, and none has been observed, indicating that the mechanism will be fully reuseable.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rao, Nageswara S.; Ramirez Aviles, Camila A.

    We consider the problem of inferring the operational status of a reactor facility using measurements from a radiation sensor network deployed around the facility’s ventilation off-gas stack. The intensity of stack emissions decays with distance, and the sensor counts or measurements are inherently random with parameters determined by the intensity at the sensor’s location. We utilize the measurements to estimate the intensity at the stack, and use it in a one-sided Sequential Probability Ratio Test (SPRT) to infer on/off status of the reactor. We demonstrate the superior performance of this method over conventional majority fusers and individual sensors using (i)more » test measurements from a network of 21 NaI detectors, and (ii) effluence measurements collected at the stack of a reactor facility. We also analytically establish the superior detection performance of the network over individual sensors with fixed and adaptive thresholds by utilizing the Poisson distribution of the counts. We quantify the performance improvements of the network detection over individual sensors using the packing number of the intensity space.« less

  8. Bayesian analysis of energy and count rate data for detection of low count rate radioactive sources.

    PubMed

    Klumpp, John; Brandl, Alexander

    2015-03-01

    A particle counting and detection system is proposed that searches for elevated count rates in multiple energy regions simultaneously. The system analyzes time-interval data (e.g., time between counts), as this was shown to be a more sensitive technique for detecting low count rate sources compared to analyzing counts per unit interval (Luo et al. 2013). Two distinct versions of the detection system are developed. The first is intended for situations in which the sample is fixed and can be measured for an unlimited amount of time. The second version is intended to detect sources that are physically moving relative to the detector, such as a truck moving past a fixed roadside detector or a waste storage facility under an airplane. In both cases, the detection system is expected to be active indefinitely; i.e., it is an online detection system. Both versions of the multi-energy detection systems are compared to their respective gross count rate detection systems in terms of Type I and Type II error rates and sensitivity.

  9. Automated Design of Noise-Minimal, Safe Rotorcraft Trajectories

    NASA Technical Reports Server (NTRS)

    Morris, Robert A.; Venable, K. Brent; Lindsay, James

    2012-01-01

    NASA and the international community are investing in the development of a commercial transportation infrastructure that includes the increased use of rotorcraft, specifically helicopters and aircraft such as a 40-passenger civil tilt rotors. Rotorcraft have a number of advantages over fixed wing aircraft, primarily in not requiring direct access to the primary fixed wing runways. As such they can operate at an airport without directly interfering with major air carrier and commuter aircraft operations. However, there is significant concern over the impact of noise on the communities surrounding the transportation facilities. In this paper we propose to address the rotorcraft noise problem by exploiting powerful search techniques coming from artificial intelligence, coupled with simulation and field tests, to design trajectories that are expected to improve on the amount of ground noise generated. This paper investigates the use of simulation based on predictive physical models to facilitate the search for low-noise trajectories using a class of automated search algorithms called local search. A novel feature of this approach is the ability to incorporate constraints into the problem formulation that addresses passenger safety and comfort.

  10. VHF Ranging and Position Fixing Experiment Using ATS Satellites: Final Report on Phases 1 and 2, 25 November 1968 - 1 May 1971

    NASA Technical Reports Server (NTRS)

    1971-01-01

    The testing program with the ATS-1 and ATS-3 spacecraft showed that geostationary satellites can provide superior communications and position surveillance for mobile craft. Inexpensive modifications to conventional mobile communications equipment aboard the craft can provide reliable, high quality voice and digital communications with distant ground stations and other vehicles, and automatic surveillance of the positions of all the craft by a ground facility. The tests also demonstrated the location and automatic readout of remote data collection platforms. Frequency modulation signals with the narrow audio and radio frequency bandwidths of terrestrial mobile radio communications were relayed through the VHF transponders of the geostationary satellites. The voice and digital communications were far superior in reliability and quality to long-distance mobile communications by other means. It was shown that one satellite can provide nearly uniform high quality performance over approximately one-third of the earth's surface. Position fixes by range measurement from the two satellites were accurate to approximately one nautical mile, except near the equator and the poles.

  11. X-Ray Testing Constellation-X Optics at MSFC's 100-m Facility

    NASA Technical Reports Server (NTRS)

    O'Dell, Stephen; Baker, Markus; Content, David; Freeman, Mark; Glenn, Paul; Gubarev, Mikhail; Hair, Jason; Jones, William; Joy, Marshall

    2003-01-01

    In addition to the 530-m-long X-Ray Calibration Facility (XRCF), NASA's Marshall Space Flight Center (MSFC) operates a 104-m-long (source-to-detector) X-ray-test facility. Originally developed and still occasionally used for stray-light testing of visible-fight optical systems, the so-called "Stray-Light Facility" now serves primarily as a convenient and inexpensive facility for performance evaluation and calibration of X-ray optics and detectors. The facility can accommodate X-ray optics up to about 1-m diameter and 12-m focal length. Currently available electron-impact sources at the facility span the approximate energy range 0.2 to 100 keV, thus supporting testing of soft- and hard-X-ray optics and detectors. Available MSFC detectors are a front-illuminated CCD (charge-coupled device) and a scanning CZT (cadmium--zinc--telluride) detector, with low-energy cut-offs of about 0.8 and 3 keV, respectively. In order to test developmental optics for the Constellation-X Project, led by NASA's Goddard Space Flight Center (GSFC), MSFC undertook several enhancements to the facility. Foremost among these was development and fabrication of a five-degree-of-freedom (5-DoF) optics mount and control system, which translates and tilts the user-provided mirror assembly suspended from its interface plate. Initial Constellation-X tests characterize the performance of the Optical Alignment Pathfinder Two (OAP2) for the large Spectroscopy X-ray Telescope (SXT) and of demonstration mirror assemblies for the Hard X-ray Telescope (HXT). With the Centroid Detector Assembly (CDA), used for precision alignment of the Chandra (nee AXAF) mirrors, the Constellation-X SXT Team optically aligned the individual mirrors of the OAPZ at GSFC. The team then developed set-up and alignment procedures, including transfer of the alignment from the optical alignment facility at GSFC to the X-ray test facility at MSFC, using a reference flat and fiducials. The OAPZ incorporates additional ancillary features --- fixed aperture mask and movable sub-aperture mask --- to facilitate X-ray characterization of the optics. Although the OAPZ was designed to- have low sensitivity to temperature offsets and gradients, analyses showed the necessity of active temperature control for the X-ray performance testing. Thus, the Smithsonian Astrophysical Observatory (SAO) implemented a thermal control and monitoring system, designed to hold the OAP2 close to its assembly.

  12. Why are hospital-based nursing homes so costly? Relative importance of acuity and treatment setting.

    PubMed

    Pizer, Steven D; White, Alan J; White, Chapin

    2002-05-01

    To determine the extent to which higher costs in hospital-based skilled nursing facilities (HBSNF) can be explained by observable resident characteristics and unobservable selection effects, implying a design shortcoming of the skilled nursing facility prospective payment system (SNF PPS) implemented for Medicare-covered stays by the Balanced Budget Act of 1997 (BBA 1997). Data on resident characteristics from the Minimum Data Set (MDS) are combined with staff time costs from the Centers for Medicare and Medicaid Services' (CMS, formerly HCFA) 1995 and 1997 SNF Staff Time Measurement (STM) studies and nontherapy ancillary claim costs extracted from CMS SNF claim records. An endogenous switching model was estimated to measure the effect on costs of the relatively high acuity of HBSNF residents, net of differences purely attributable to the treatment setting. It was found that virtually the entire HBSNF differential is attributable to setting effects with resident characteristics and selection effects playing a negligible role. In addition, it was found that marginal costs associated with particular services and conditions are often lower in hospital-based than in freestanding facilities. HBSNFs incur high costs regardless of the characteristics of their residents. Their high fixed costs accompany relatively low marginal costs associated with admitting high-acuity residents. Consequently, a PPS casemix system that depends on resident characteristics and excludes consideration of facility characteristics (as mandated by BBA 1997) need not unfairly penalize HBSNFs, provided a powerful casemix system is used and HBSNFs specialize in the care of high-acuity residents.

  13. The effect of state medicaid case-mix payment on nursing home resident acuity.

    PubMed

    Feng, Zhanlian; Grabowski, David C; Intrator, Orna; Mor, Vincent

    2006-08-01

    To examine the relationship between Medicaid case-mix payment and nursing home resident acuity. Longitudinal Minimum Data Set (MDS) resident assessments from 1999 to 2002 and Online Survey Certification and Reporting (OSCAR) data from 1996 to 2002, for all freestanding nursing homes in the 48 contiguous U.S. states. We used a facility fixed-effects model to examine the effect of introducing state case-mix payment on changes in nursing home case-mix acuity. Facility acuity was measured by aggregating the nursing case-mix index (NCMI) from the MDS using the Resource Utilization Group (Version III) resident classification system, separately for new admits and long-stay residents, and by an OSCAR-derived index combining a range of activity of daily living dependencies and special treatment measures. We followed facilities over the study period to create a longitudinal data file based on the MDS and OSCAR, respectively, and linked facilities with longitudinal data on state case-mix payment policies for the same period. Across three acuity measures and two data sources, we found that states shifting to case-mix payment increased nursing home acuity levels over the study period. Specifically, we observed a 2.5 percent increase in the average acuity of new admits and a 1.3 to 1.4 percent increase in the acuity of long-stay residents, following the introduction of case-mix payment. The adoption of case-mix payment increased access to care for higher acuity Medicaid residents.

  14. The effect of state policies on nursing home resident outcomes.

    PubMed

    Mor, Vincent; Gruneir, Andrea; Feng, Zhanlian; Grabowski, David C; Intrator, Orna; Zinn, Jacqueline

    2011-01-01

    To test the effect of changes in Medicaid reimbursement on clinical outcomes of long-stay nursing home (NH) residents. Longitudinal, retrospective study of NHs, merging aggregated resident-level quality measures with facility characteristics and state policy survey data. All free-standing NHs in urban counties with at least 20 long-stay residents per quarter (length of stay > 90 days) in the continental United States between 1999 and 2005. Long-stay NH residents Annual state Medicaid average per diem reimbursement and the presence of case-mix reimbursement in each year. Quarterly facility-aggregated, risk-adjusted quality-of-care measures surpassing a threshold for functional (activity of daily living) decline, physical restraint use, pressure ulcer incidence or worsening, and persistent pain. All outcomes showed an improvement trend over the study period, particularly physical restraint use. Facility fixed-effect regressions revealed that a $10 increase in Medicaid payment increased the likelihood of a NH meeting quality thresholds by 9% for functional decline, 5% for pain control, and 2% for pressure ulcers but not reduced use of physical restraints. Facilities in states that increased Medicaid payment most showed the greatest improvement in outcomes. The introduction of case-mix reimbursement was unrelated to quality improvement. Improvements in the clinical quality of NH care have been achieved, particularly where Medicaid payment has increased, generally from a lower baseline. Although this is a positive finding, challenges to implementing efficient reimbursement policies remain. © 2010, Copyright the Authors. Journal compilation © 2010, The American Geriatrics Society.

  15. Application of microwave radiometry to improving climate data records.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liljegren, J. C.; Cadeddu, M. P.; Decision and Information Sciences

    2007-01-01

    Microwave radiometers deployed by the U. S. Department of Energy's Atmospheric Radiation Measurement (ARM) Program provide crucial data for a wide range of research applications. The accuracy and stability of these instruments also makes them ideal for improving climate data records: to detect and correct discontinuities in the long-term climate records, to validate and calibrate the climate data, to characterize errors in the climate records, and to plan for the future Global Climate Observing System (GCOS) Reference Upper-Air network. This paper presents an overview of these capabilities with examples from ARM data. Two-channel microwave radiometers (MWR) operating at 23.8 andmore » 31.4 GHz are deployed at each of eleven ARM Climate Research Facility (ACRF) field sites in the U.S. Southern Great Plains (SGP), Tropical Western Pacific (TWP), North Slope of Alaska (NSA), and with the ARM Mobile Facility in Niamey, Niger for the purpose of retrieving precipitable water vapor (PWV) and liquid water path (LWP). At these locations PWV ranges from as low as 1 mm (1 kg/m{sup 2}) at the NSA to 70 mm or more in the TWP; LWP can exceed 2 mm at many sites. The MWR accommodates this wide dynamic range for all non-precipitating conditions with a root-mean-square error of about 0.4 mm for PWV and 0.02 mm (20 g/m{sup 2}) for LWP. The calibration of the MWR is continuously and autonomously monitored and updated to maintain accuracy. Comparisons of collocated MWRs will be presented. Site-specific linear statistical retrievals are used operationally; more sophisticated retrievals are applied in post-processing the data. Because PWV is an integral measure, derived from both the relative humidity and temperature profiles of the radiosonde, it is a particularly useful reference quantity. Comparison of PWV measured by the MWR with PWV from radiosondes reveals dry biases and diurnal trends as well as general calibration variability in the radiosondes. To correct the bias and reduce the variability ARM scales the relative humidity measurements from the radiosondes to produce agreement with the PWV measured by the MWR. Comparisons of infrared spectral radiances calculated using these scaled radiosondes with high spectral resolution measurements exhibit dramatically reduced bias and variability. This ability to detect and correct errors in the radiosondes measurements will be critical for detecting climate change. The MWR has also been used for a variety of ground- and satellite-based remote sensor retrieval development and validation studies, including precipitable water vapor and slant water vapor retrievals using the Global Positioning System (GPS). The MWR can provide a valuable comparison for GPS-derived zenith wet delay and PWV values, e.g., for evaluating improved mapping functions and detecting errors due, for example, to multi-path contributions. For precipitable water vapor amounts less than 4 mm, which commonly occur in cold, dry Arctic conditions, the 0.4 mm root-mean-square error of the MWR precipitable water vapor measurement is problematic. To obtain increased sensitivity under these conditions, a new G-band water vapor radiometer (GVR) operating at 183.31 {+-} 1, {+-}3, {+-}7, and {+-}14 GHz is deployed at the NSA Barrow site. The GVR offers a valuable reference for radiosonde and GPS water vapor measurements at Arctic locations that are expected to be particularly sensitive to climate change.« less

  16. Three methods to monitor utilization of healthcare services by the poor

    PubMed Central

    Bhuiya, Abbas; Hanifi, SMA; Urni, Farhana; Mahmood, Shehrin Shaila

    2009-01-01

    Background Achieving equity by way of improving the condition of the economically poor or otherwise disadvantaged is among the core goals of contemporary development paradigm. This places importance on monitoring outcome indicators among the poor. National surveys allow disaggregation of outcomes by socioeconomic status at national level and do not have statistical adequacy to provide estimates for lower level administrative units. This limits the utility of these data for programme managers to know how well particular services are reaching the poor at the lowest level. Managers are thus left without a tool for monitoring results for the poor at lower levels. This paper demonstrates that with some extra efforts community and facility based data at the lower level can be used to monitor utilization of healthcare services by the poor. Methods Data used in this paper came from two sources- Chakaria Health and Demographic Surveillance System (HDSS) of ICDDR,B and from a special study conducted during 2006 among patients attending the public and private health facilities in Chakaria, Bangladesh. The outcome variables included use of skilled attendants for delivery and use of facilities. Rate-ratio, rate-difference, concentration index, benefit incidence ratio, sequential sampling, and Lot Quality Assurance Sampling were used to assess how pro-poor is the use of skilled attendants for delivery and healthcare facilities. Findings Poor are using skilled attendants for delivery far less than the better offs. Government health service facilities are used more than the private facilities by the poor. Benefit incidence analysis and sequential sampling techniques could assess the situation realistically which can be used for monitoring utilization of services by poor. The visual display of the findings makes both these methods attractive. LQAS, on the other hand, requires small fixed sample and always enables decision making. Conclusion With some extra efforts monitoring of the utilization of healthcare services by the poor at the facilities can be done reliably. If monitored, the findings can guide the programme and facility managers to act in a timely fashion to improve the effectiveness of the programme in reaching the poor. PMID:19650938

  17. Managerial Ownership in Nursing Homes: Staffing, Quality, and Financial Performance.

    PubMed

    Huang, Sean Shenghsiu; Bowblis, John R

    2017-06-20

    Ownership of nursing homes (NHs) has primarily focused broadly on differences between for-profit (FP), nonprofit (NFP), and government-operated facilities. Yet, among FPs, the understanding of detailed ownership structures at individual NHs is rather limited. Particularly, NH administrators may hold significant equity interests in their facilities, leading to heterogeneous financial incentives and NH outcomes. Through the principal-agent theory, this article studies how managerial ownership of individual facilities affects NH outcomes. We use a unique panel dataset of Ohio NHs (2005-2010) to empirically examine the relationship between managerial equity ownership and NH staffing, quality, and financial performance. We identify facility administrators as owner-managers if they have more than 5% of the equity stakes or are relatives of the owners. The statistical analysis is based on the pooled ordinary least squares and NH-fixed effect models. We find that owner-managed NHs are associated with higher nursing staff levels compared to other FP NHs. Surprisingly, despite higher staffing levels, owner-managed NHs are not associated with better quality and we find no statistically significant difference in financial performance between owner-managed and nonowner-managed FP NHs. Our results do not support the principal-agent model and we offer alternative explanations for future research. Our findings provide empirical evidence that NH ownership structures are more nuanced than simply broadly categorizing facilities as FP or NFP, and our results do not fully align with the standard principal-agent model. The role of managerial ownership should be considered in future NH research and policy discussions. © The Author 2017. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  18. Medicaid provisions and the US mental health industry composition.

    PubMed

    Pellegrini, Lawrence C; Rodriguez-Monguio, Rosa

    2014-12-01

    Medicaid is the largest payer for mental health (MH) services. This study examines associations between Medicaid provisions and the MH industry composition. Medicaid data derived from the Centers for Medicare and Medicaid Services. MH facility gross payroll and occupational employment data derived from the Bureau of Labor Statistics. State fixed-effects regression models are performed to examine associations. In the 1999-2009 period, per-capita gross payroll gains are largest for residential MH and substance abuse (SA) facilities and MH practitioner offices, followed by MH clinics and physician offices. Likewise, occupational employment gains per 100 000 people are largest for MH and SA social workers and MH counselors, followed by psychiatrists and psychologists. The Medicaid beneficiary rate is related with gross payroll gains at residential MH and SA facilities (p < 0.001) and MH clinics (p < 0.001), and with employment gains for MH and SA social workers (p < 0.001) and MH counselors (p < 0.001). Smaller effect sizes exist with MH physician offices (p < 0.05) and psychiatric hospitals' (p < 0.01) gross payroll. No statistically significant relationship exists between the Medicaid beneficiary rate and psychiatrist and psychologist employment. Medicaid provisions are related with the MH industry composition. An imbalanced MH industry may lead to inadequate management of MH disorders.

  19. Joint Optimization of Distribution Network Design and Two-Echelon Inventory Control with Stochastic Demand and CO2 Emission Tax Charges

    PubMed Central

    Li, Shuangyan; Li, Xialian; Zhang, Dezhi; Zhou, Lingyun

    2017-01-01

    This study develops an optimization model to integrate facility location and inventory control for a three-level distribution network consisting of a supplier, multiple distribution centers (DCs), and multiple retailers. The integrated model addressed in this study simultaneously determines three types of decisions: (1) facility location (optimal number, location, and size of DCs); (2) allocation (assignment of suppliers to located DCs and retailers to located DCs, and corresponding optimal transport mode choices); and (3) inventory control decisions on order quantities, reorder points, and amount of safety stock at each retailer and opened DC. A mixed-integer programming model is presented, which considers the carbon emission taxes, multiple transport modes, stochastic demand, and replenishment lead time. The goal is to minimize the total cost, which covers the fixed costs of logistics facilities, inventory, transportation, and CO2 emission tax charges. The aforementioned optimal model was solved using commercial software LINGO 11. A numerical example is provided to illustrate the applications of the proposed model. The findings show that carbon emission taxes can significantly affect the supply chain structure, inventory level, and carbon emission reduction levels. The delay rate directly affects the replenishment decision of a retailer. PMID:28103246

  20. Evaluation of Electric Power Procurement Strategies by Stochastic Dynamic Programming

    NASA Astrophysics Data System (ADS)

    Saisho, Yuichi; Hayashi, Taketo; Fujii, Yasumasa; Yamaji, Kenji

    In deregulated electricity markets, the role of a distribution company is to purchase electricity from the wholesale electricity market at randomly fluctuating prices and to provide it to its customers at a given fixed price. Therefore the company has to take risk stemming from the uncertainties of electricity prices and/or demand fluctuation instead of the customers. The way to avoid the risk is to make a bilateral contact with generating companies or install its own power generation facility. This entails the necessity to develop a certain method to make an optimal strategy for electric power procurement. In such a circumstance, this research has the purpose for proposing a mathematical method based on stochastic dynamic programming and additionally considering the characteristics of the start-up cost of electric power generation facility to evaluate strategies of combination of the bilateral contract and power auto-generation with its own facility for procuring electric power in deregulated electricity market. In the beginning we proposed two approaches to solve the stochastic dynamic programming, and they are a Monte Carlo simulation method and a finite difference method to derive the solution of a partial differential equation of the total procurement cost of electric power. Finally we discussed the influences of the price uncertainty on optimal strategies of power procurement.

  1. Model Deformation Measurements at NASA Langley Research Center

    NASA Technical Reports Server (NTRS)

    Burner, A. W.

    1998-01-01

    Only recently have large amounts of model deformation data been acquired in NASA wind tunnels. This acquisition of model deformation data was made possible by the development of an automated video photogrammetric system to measure the changes in wing twist and bending under aerodynamic load. The measurement technique is based upon a single view photogrammetric determination of two dimensional coordinates of wing targets with a fixed third dimensional coordinate, namely the spanwise location. A major consideration in the development of the measurement system was that use of the technique must not appreciably reduce wind tunnel productivity. The measurement technique has been used successfully for a number of tests at four large production wind tunnels at NASA and a dedicated system is nearing completion for a fifth facility. These facilities are the National Transonic Facility, the Transonic Dynamics Tunnel, and the Unitary Plan Wind Tunnel at NASA Langley, and the 12-FT Pressure Tunnel at NASA Ames. A dedicated system for the Langley 16-Foot Transonic Tunnel is scheduled to be used for the first time for a test in September. The advantages, limitations, and strategy of the technique as currently used in NASA wind tunnels are presented. Model deformation data are presented which illustrate the value of these measurements. Plans for further enhancements to the technique are presented.

  2. Radiation predictions and shielding calculations for RITS-6

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maenchen, John Eric; O'Malley, John; Kensek, Ronald Patrick

    2005-06-01

    The mission of Radiographic Integrated Test Stand-6 (RITS-6) facility is to provide the underlying science and technology for pulsed-power-driven flash radiographic X-ray sources for the National Nuclear Security Administration (NNSA). Flash X-ray radiography is a penetrating diagnostic to discern the internal structure in dynamic experiments. Short (~50 nanosecond (ns) duration) bursts of very high intensity Xrays from mm-scale source sizes are required at a variety of voltages to address this mission. RITS-6 was designed and is used to both develop the accelerator technology needed for these experiments and serves as the principal test stand to develop the high intensity electronmore » beam diodes that generate the required X-ray sources. RITS is currently in operation with three induction cavities (RITS-3) with a maximum voltage output of 5.5 MV and is classified as a low hazard non-nuclear facility in accordance with CPR 400.1.1, Chapter 13, Hazards Identification/Analysis and Risk Management. The facility will be expanded from three to six cavities (RITS-6) effectively doubling the operating voltage. The increase in the operating voltage to above 10 MV has resulted in RITS-6 being classified as an accelerator facility. RITS-6 will come under DOE Order 420.2B, Safety of Accelerator Facilities. The hazards of RITS are detailed in the "Safety Assessment Document for the Radiographic Integrated Test Stand Facility." The principal non-industrial hazard is prompt x-ray radiation. As the operating voltage is increased, both the penetration power and the total amount (dose) of x-rays are increased, thereby increasing the risk to local personnel. Fixed site shielding (predominantly concrete walls and a steel/lead skyshine shield) is used to attenuate these x-rays and mitigate this risk. This SAND Report details the anticipated x-ray doses, the shielding design, and the anticipated x-ray doses external to this shielding structure both in areas where administrative access control restricts occupation and in adjacent uncontrolled areas.« less

  3. Jeopardizing quality at the frontline of healthcare: prevalence and risk factors for disrespect and abuse during facility-based childbirth in Ethiopia

    PubMed Central

    Karim, Ali M; Ratcliffe, Hannah L; Betemariam, Wuleta; Langer, Ana

    2018-01-01

    Abstract Disrespect and abuse (D&A) experienced by women during facility-based childbirth has gained global recognition as a threat to eliminating preventable maternal mortality and morbidity. This study explored the frequency and associated factors of D&A in four rural health centres in Ethiopia. Experiences of women who delivered in these facilities were captured by direct observation of client-provider interaction (N = 193) and exit interview at time of discharge (N = 204). Incidence of D&A was observed in each facility, with failure to ask woman for preferred birth position most commonly observed [n = 162, 83.9%, 95% confidence interval (95% CI) 78.0–88.5%]. During exit interviews, 21.1% (n = 43, 95% CI 15.4–26.7%) of respondents reported at least one occurrence of D&A. Bivariate models using client characteristics and index birth experience showed that women’s reporting of D&A was significantly associated with childbirth complications [odds ratio (OR) = 7.98, 95% CI 3.70, 17.22], weekend delivery (OR = 0.17, 95% CI 0.05, 0.63) and no previous delivery at the facility (OR = 3.20, 95% CI 1.27, 8.05). Facility-level fixed-effect models found that experience of complications (OR = 15.51, 95% CI 4.38, 54.94) and weekend delivery (OR = 0.05, 95% CI 0.01–0.32) remained significantly and most strongly associated with self-reported D&A. These data suggest that addressing D&A in health centres in Ethiopia will require a sustained effort to improve infrastructure, support the health workforce in rural settings, enforce professional standards and target interventions to improve women’s experiences as part of quality of care initiatives. PMID:29309598

  4. State Parity Laws and Access to Treatment for Substance Use Disorder in the United States: Implications for Federal Parity Legislation

    PubMed Central

    Wen, Hefei; Cummings, Janet R.; Hockenberry, Jason M.; Gaydos, Laura M.; Druss, Benjamin G.

    2014-01-01

    Context The passage of the 2008 Mental Health Parity and Addiction Equity Act (MHPAEA) and the 2010 Affordable Care Act (ACA) incorporated parity for substance use disorder (SUD) into federal legislation. Yet prior research provides us with scant evidence as to whether federal parity legislation will hold the potential for improving access to SUD treatment. Objective This study examined the effect of state-level SUD parity laws on state-aggregate SUD treatment rates from 2000 to 2008, to shed light on the impact of the recent federal-level SUD parity legislation. Design A quasi-experimental study design using a two-way (state and year) fixed-effect method Setting and Participants All known specialty SUD treatment facilities in the United States Interventions State-level SUD parity laws between 2000 and 2008 Main Outcome Measures State-aggregate SUD treatment rates in: (1) all specialty SUD treatment facilities, and (2) specialty SUD treatment facilities accepting private insurance Results The implementation of any SUD parity law increased the treatment rate by 9 percent (p<0.01) in all specialty SUD treatment facilities and by 15 percent (p<0.05) in facilities accepting private insurance. Full parity and parity-if-offered (i.e., parity only if SUD coverage is offered) increased SUD treatment rate by 13 percent (p<0.05) and 8 percent (p<0.05) in all facilities, and by 21 percent (p<0.05) and 10 percent (p<0.05) in those accepting private insurance. Conclusions We found a positive effect of the implementation of state SUD parity legislation on access to specialty SUD treatment. Furthermore, the positive association was more pronounced in states with more comprehensive parity laws. Our findings suggest that federal parity legislation holds the potential to improve access to SUD treatment. PMID:24154931

  5. Restructuring in response to case mix reimbursement in nursing homes: A contingency approach

    PubMed Central

    Zinn, Jacqueline; Feng, Zhanlian; Mor, Vincent; Intrator, Orna; Grabowski, David

    2013-01-01

    Background Resident-based case mix reimbursement has become the dominant mechanism for publicly funded nursing home care. In 1998 skilled nursing facility reimbursement changed from cost-based to case mix adjusted payments under the Medicare Prospective Payment System for the costs of all skilled nursing facility care provided to Medicare recipients. In addition, as of 2004, 35 state Medicaid programs had implemented some form of case mix reimbursement. Purpose The purpose of the study is to determine if the implementation of Medicare and Medicaid case mix reimbursement increased the administrative burden on nursing homes, as evidenced by increased levels of nurses in administrative functions. Methodology/Approach The primary data for this study come from the Centers for Medicare and Medicaid Services Online Survey Certification and Reporting database from 1997 through 2004, a national nursing home database containing aggregated facility-level information, including staffing, organizational characteristics and resident conditions, on all Medicare/Medicaid certified nursing facilities in the country. We conducted multivariate regression analyses using a facility fixed-effects model to examine the effects of the implementation of Medicaid case mix reimbursement and Medicare Prospective Payment System on changes in the level of total administrative nurse staffing in nursing homes. Findings Both Medicaid case mix reimbursement and Medicare Prospective Payment System increased the level of administrative nurse staffing, on average by 5.5% and 4.0% respectively. However, lack of evidence for a substitution effect suggests that any decline in direct care staffing after the introduction of case mix reimbursement is not attributable to a shift from clinical nursing resources to administrative functions. Practice Implications Our findings indicate that the administrative burden posed by case mix reimbursement has resource implications for all freestanding facilities. At the margin, the increased administrative burden imposed by case mix may become a factor influencing a range of decisions, including resident admission and staff hiring. PMID:18360162

  6. Restructuring in response to case mix reimbursement in nursing homes: a contingency approach.

    PubMed

    Zinn, Jacqueline; Feng, Zhanlian; Mor, Vincent; Intrator, Orna; Grabowski, David

    2008-01-01

    Resident-based case mix reimbursement has become the dominant mechanism for publicly funded nursing home care. In 1998 skilled nursing facility reimbursement changed from cost-based to case mix adjusted payments under the Medicare Prospective Payment System for the costs of all skilled nursing facility care provided to Medicare recipients. In addition, as of 2004, 35 state Medicaid programs had implemented some form of case mix reimbursement. The purpose of the study is to determine if the implementation of Medicare and Medicaid case mix reimbursement increased the administrative burden on nursing homes, as evidenced by increased levels of nurses in administrative functions. The primary data for this study come from the Centers for Medicare and Medicaid Services Online Survey Certification and Reporting database from 1997 through 2004, a national nursing home database containing aggregated facility-level information, including staffing, organizational characteristics and resident conditions, on all Medicare/Medicaid certified nursing facilities in the country. We conducted multivariate regression analyses using a facility fixed-effects model to examine the effects of the implementation of Medicaid case mix reimbursement and Medicare Prospective Payment System on changes in the level of total administrative nurse staffing in nursing homes. Both Medicaid case mix reimbursement and Medicare Prospective Payment System increased the level of administrative nurse staffing, on average by 5.5% and 4.0% respectively. However, lack of evidence for a substitution effect suggests that any decline in direct care staffing after the introduction of case mix reimbursement is not attributable to a shift from clinical nursing resources to administrative functions. Our findings indicate that the administrative burden posed by case mix reimbursement has resource implications for all freestanding facilities. At the margin, the increased administrative burden imposed by case mix may become a factor influencing a range of decisions, including resident admission and staff hiring.

  7. Aquifer disposal of carbon dioxide for greenhouse effect mitigation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gupta, N.; Naymik, T.G.; Bergman, P.

    1998-07-01

    Deep aquifer sequestration of carbon dioxide (CO{sup 2}), generated from power plant and other industrial emissions, is being evaluated as one of the potential options for the reduction of atmospheric greenhouse gas emissions. The major advantages of using deep aquifers are that the disposal facilities may be located close to the sources, thus reducing the CO{sub 2} transport costs. The potential capacity is much larger than the projected CO{sub 2} emissions over the next century, and it is a long-term/permanent sequestration option, because a large portion of the injected CO{sub 2} may be fixed into the aquifer by dissolution ormore » mineralization. The major limitations include the potentially high cost, the risk of upward migration, and the public perception of risk. Most of the cost is due to the need to separate CO{sub 2} from other flue gases, rather than the actual cost of disposal. Hazardous liquid waste and acid gas disposal in deep sedimentary formations is a well-established practice. There are also numerous facilities for storage of natural gases in depleted oil and gas reservoirs. The only current facility for aquifer disposal of CO{sub 2} is the offshore injection well at Sleipner Vest in the North Sea in Norway operated by Statoil. Exxon and Pertamina are planning an offshore aquifer disposal facility at Natuna gas field in Indonesia. A major evaluation of the feasibility of CO{sub 2} disposal in the European Union and Norway has been conducted under project Joule II. The data and experience obtained from the existing deep-waste disposal facilities and from the Sleipner Vest site form a strong foundation for further research and development on CO{sub 2} sequestration. Federal Energy Technology Center (FETC) is currently leading a project that uses data from an existing hazardous waste disposal facility injecting in the Mt. Simon Sandstone aquifer in Ohio to evaluate hydrogeologic, geochemical, and social issues related to CO{sub 2} disposal.« less

  8. Aquifer disposal of carbon dioxide for greenhouse effect mitigation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gupta, N.; Naymik, T.G.; Bergman, P.

    1998-04-01

    Deep aquifer sequestration of carbon dioxide (CO{sub 2}) generated from power plant and other industrial emissions, is being evaluated as one of the potential options for the reduction of atmospheric greenhouse gas emissions. The major advantages of using deep aquifers are that the disposal facilities may be located close to the sources, thus reducing the CO{sub 2} transport costs. The potential capacity is much larger than the projected CO{sub 2} emissions over the next century, and it is a long-term/permanent sequestration option, because a large portion of the injected CO{sub 2} may be fixed into the aquifer by dissolution ormore » mineralization. The major limitations include the potentially high cost, the risk of upward migration, and the public perception of risk. Most of the cost is due to the need to separate CO{sub 2} from other flue gases, rather than the actual cost of disposal. Hazardous liquid waste and acid gas disposal in deep sedimentary formations is a well-established practice. There are also numerous facilities for storage of natural gases in depleted oil and gas reservoirs. The only current facility for aquifer disposal of CO{sub 2} is the offshore injection well at Sleipner Vest in the North Sea in Norway operated by Statoil. Exxon and Pertamina are planning an offshore aquifer disposal facility at Natuna gas field in Indonesia. A major evaluation of the feasibility of CO{sub 2} disposal in the European Union and Norway has been conducted under project Joule II. The data and experience obtained from the existing deep-waste disposal facilities and from the Sleipner Vest site form a strong foundation for further research and development on CO{sub 2} sequestration. Federal Energy Technology Center (FETC) is currently leading a project that uses data from an existing hazardous waste disposal facility injecting in the Mt. Simon Sandstone aquifer in Ohio to evaluate hydrogeologic, geochemical, and social issues related to CO{sub 2} disposal.« less

  9. Learning from Demonstration: Generalization via Task Segmentation

    NASA Astrophysics Data System (ADS)

    Ettehadi, N.; Manaffam, S.; Behal, A.

    2017-10-01

    In this paper, a motion segmentation algorithm design is presented with the goal of segmenting a learned trajectory from demonstration such that each segment is locally maximally different from its neighbors. This segmentation is then exploited to appropriately scale (dilate/squeeze and/or rotate) a nominal trajectory learned from a few demonstrations on a fixed experimental setup such that it is applicable to different experimental settings without expanding the dataset and/or retraining the robot. The algorithm is computationally efficient in the sense that it allows facile transition between different environments. Experimental results using the Baxter robotic platform showcase the ability of the algorithm to accurately transfer a feeding task.

  10. STS-44 Atlantis, OV-104, crewmembers participate in FB-SMS training at JSC

    NASA Technical Reports Server (NTRS)

    1991-01-01

    STS-44 Atlantis, Orbiter Vehicle (OV) 104, Commander Frederick D. Gregory (left) and Pilot Terence T. Henricks (right), positioned at their appointed stations on the forward flight deck, are joined by Mission Specialist (MS) F. Story Musgrave (center). The crewmembers are participating in a flight simulation in the Fixed Base (FB) Shuttle Mission Simulator (SMS) located in JSC's Mission Simulation and Training Facility Bldg 5. Gregory in the commanders seat, Musgrave sitting on center console, and Henricks in the pilots seat look back toward the aft flight deck and the photographer. Seat backs appear in the foreground and forward control panels in the background.

  11. Electrical Arc Ignition Testing for Constellation Program

    NASA Technical Reports Server (NTRS)

    Sparks, Kyle; Gallus, Timothy; Smith, Sarah

    2009-01-01

    NASA Johnson Space Center (JSC) Materials and Processes Branch requested that NASA JSC White Sands Test Facility (WSTF) perform testing for the Constellation Program to evaluate the hazard of electrical arc ignition of materials that could be in close proximity to batteries. Specifically, WSTF was requested to perform wire-break electrical arc tests to determine the current threshold for ignition of generic cotton woven fabric samples with a fixed voltage of 3.7 V, a common voltage for hand-held electrical devices. The wire-break test was developed during a previous test program to evaluate the hazard of electrical arc ignition inside the Extravehicular Mobility Unit [1].

  12. Prospects for the study of the properties of dense nuclear matter at the NICA heavy-ion complex at JINR (Dubna)

    NASA Astrophysics Data System (ADS)

    Kolesnikov, V. I.

    2017-06-01

    The NICA (Nuclotron-based Ion Collider fAcility) project is aimed in the construction at JINR (Dubna) a modern accelerator complex equipped with three detectors: the MultiPurpose Detector (MPD) and the Spin Physics Detector (SPD) at the NICA collider, as well as a fixed target experiment BM&N which will be use extracted beams from the Nuclotron accelerator. In this report, an overview of the main physics objectives of the NICA heavy-ion program will be given and the recent progress in the NICA construction (both accelerator complex and detectors) will be described.

  13. Experimental aeroelasticity history, status and future in brief

    NASA Technical Reports Server (NTRS)

    Ricketts, Rodney H.

    1990-01-01

    NASA conducts wind tunnel experiments to determine and understand the aeroelastic characteristics of new and advanced flight vehicles, including fixed-wing, rotary-wing and space-launch configurations. Review and assessments are made of the state-of-the-art in experimental aeroelasticity regarding available facilities, measurement techniques, and other means and devices useful in testing. In addition, some past experimental programs are described which assisted in the development of new technology, validated new analysis codes, or provided needed information for clearing flight envelopes of unwanted aeroelastic response. Finally, needs and requirements for advances and improvements in testing capabilities for future experimental research and development programs are described.

  14. Experimental Investigation of Diffuser Pressure-ratio Control with Shock-positioning Limit on 28-inch Ram-jet Engine

    NASA Technical Reports Server (NTRS)

    Dunbar, William R; Wentworth, Carl B; Crowl, Robert J

    1957-01-01

    The performance of a control system designed for variable thrust applications was determined in an altitude free-jet facility at various Mach numbers, altitudes and angles of attack for a wide range of engine operation. The results are presented as transient response characteristics for step disturbances in fuel flow and stability characteristics as a function of control constants and engine operating conditions. The results indicate that the control is capable of successful operation over the range of conditions tested, although variations in engine gains preclude optimum response characteristics at all conditions with fixed control constants.

  15. Biosphere 2 test module experimentation program

    NASA Technical Reports Server (NTRS)

    Alling, Abigail; Leigh, Linda S.; Maccallum, Taber; Alvarez-Romo, Norberto

    1990-01-01

    The Biosphere 2 Test Module is a facility which has the capability to do either short or long term closures: five month closures with plants were conducted. Also conducted were investigations of specific problems, such as trace gas purification by bioregenerative systems by in-putting a fixed concentration of a gas and observing its uptake over time. In other Test Module experiments, the concentration of one gas was changed to observe what effects this has on other gases present or on the system. The science of biospherics which encompasses the study of closed biological systems provides an opening into the future in space as well as in the Earth's biosphere.

  16. Assessing the pro-poor effect of different contracting schemes for health services on health facilities in rural Afghanistan.

    PubMed

    Alonge, Olakunle; Gupta, Shivam; Engineer, Cyrus; Salehi, Ahmad Shah; Peters, David H

    2015-12-01

    Despite progress in improving health outcomes in Afghanistan by contracting public health services through non-governmental organizations (NGOs), inequity in access persists between the poor and non-poor. This study examined the distributive effect of different contracting types on primary health services provision between the poor and non-poor in rural Afghanistan. Contracts to NGOs were made to deliver a common set of primary care services in each province, with the funding agencies determining contract terms. The contracting approaches could be classified into three contracting out types (CO-1, CO-2 and CO-3) and a contracting-in (CI) approach based on the contract terms, design and implementation. Exit interviews of patients attending randomly sampled primary health facilities were collected through systematic sampling across 28 provinces at two time points. The outcome, the odds that a client attending a health facility is poor, was modelled using logistic regression with a robust variance estimator, and the effect of contracting was estimated using the difference-in-difference approach combined with stratified analyses. The sample covered 5960 interviews from 306 health facilities in 2005 and 2008. The adjusted odds of a poor client attending a health facility over time increased significantly for facilities under CO-1 and CO-2, with odds ratio of 2.82 (1.49, 5.36) P-value 0.001 and 2.00 (1.33, 3.02) P-value 0.001, respectively. The odds ratios for those under CO-3 and CI were not statistically significantly different over time. When compared with the non-contracting facilities, the adjusted ratio of odds ratios of poor status among clients was significantly higher for only those under CO-1, ratio of 2.50 (1.32, 4.74) P-value 0.005. CO-1 arrangement which allows contractors to decide on how funds are allocated within a fixed lump sum with non-negotiable deliverables, and actively managed through an independent government agency, is effective in improving equity of health services provision. Published by Oxford University Press in association with The London School of Hygiene and Tropical Medicine © The Author 2014; all rights reserved.

  17. The Effect of State Medicaid Case-Mix Payment on Nursing Home Resident Acuity

    PubMed Central

    Feng, Zhanlian; Grabowski, David C; Intrator, Orna; Mor, Vincent

    2006-01-01

    Objective To examine the relationship between Medicaid case-mix payment and nursing home resident acuity. Data Sources Longitudinal Minimum Data Set (MDS) resident assessments from 1999 to 2002 and Online Survey Certification and Reporting (OSCAR) data from 1996 to 2002, for all freestanding nursing homes in the 48 contiguous U.S. states. Study Design We used a facility fixed-effects model to examine the effect of introducing state case-mix payment on changes in nursing home case-mix acuity. Facility acuity was measured by aggregating the nursing case-mix index (NCMI) from the MDS using the Resource Utilization Group (Version III) resident classification system, separately for new admits and long-stay residents, and by an OSCAR-derived index combining a range of activity of daily living dependencies and special treatment measures. Data Collection/Extraction Methods We followed facilities over the study period to create a longitudinal data file based on the MDS and OSCAR, respectively, and linked facilities with longitudinal data on state case-mix payment policies for the same period. Principal Findings Across three acuity measures and two data sources, we found that states shifting to case-mix payment increased nursing home acuity levels over the study period. Specifically, we observed a 2.5 percent increase in the average acuity of new admits and a 1.3 to 1.4 percent increase in the acuity of long-stay residents, following the introduction of case-mix payment. Conclusions The adoption of case-mix payment increased access to care for higher acuity Medicaid residents. PMID:16899009

  18. Micro-focused Small Angle Neutron Scattering and Imaging for Science and Engineering Using RTP--A Preliminary Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mohamed, Abdul Aziz; Al Rashid Megat Ahmad, Megat Harun; Md Idris, Faridah

    2010-01-05

    Malaysian Nuclear Agency's (Nuclear Malaysia) Small Angle Neutron Scattering (SANS) facility--(MYSANS)--is utilizing low flux of thermal neutron at the agency's 1 MW TRIGA reactor. As the design nature of the 8 m SANS facility can allow object resolution in the range between 5 and 80 nm to be obtained. It can be used to study alloys, ceramics and polymers in certain area of problems that relate to samples containing strong scatterers or contrast. The current SANS system at Malaysian Nuclear Agency is only capable to measure Q in limited range with a PSD (128x128) fixed at 4 m from themore » sample. The existing reactor hall that incorporate this MYSANS facility has a layout that prohibits the rebuilding of MYSANS therefore the position between the wavelength selector (HOPG) and sample and the PSD cannot be increased for wider Q range. The flux of the neutron at current sample holder is very low which around 10{sup 3} n/cm{sup 2}/sec. Thus it is important to rebuild the MYSANS to maximize the utilization of neutron. Over the years, the facility has undergone maintenance and some changes have been made. Modification on secondary shutter and control has been carried out to improve the safety level of the instrument. A compact micro-focus SANS method can suit this objective together with an improve cryostat system. This paper will explain some design concept and approaches in achieving higher flux and the modification needs to establish the micro-focused SANS.« less

  19. Incident Involving 30-Ah Li-ion Cell at NASA Glenn Research Center

    NASA Technical Reports Server (NTRS)

    Bennett, William

    2006-01-01

    The key lesson learned from the February 17, 2006 cell explosion incident is that PC-based test-systems, even those having built-in watchdog monitors, can lose control and malfunction. In the case of lithiumion cell/battery testing, the stored energy can be released explosively causing considerable injury and damage to facilities. The investigation showed that although the Arbin system has a built-in watchdog monitor, the circumstances of the incident defeated the action of the watchdog and allowed the cycler to continue operation without control. An upgrade to the most recent version of Arbin software (version 4) was provided as a fix to the presumed control problem. This upgrade included newer EPROM s for the cycler microprocessor. Investigation revealed that similar incidents have occurred at other NASA centers with a variety of PC-based test instruments. JPL suffered an incident with Maccor testers and the GRC fuel cell group observed similar problems with LabView software. This is not exclusively an Arbin problem, but an issue with all PC-based systems. In this incident, it was fortunate that the event occurred after-hours with no-one in the room. The facility arrangement placed control consoles adjacent to the test chamber doors. Had someone been in the room during the event, they would have been exposed to hot debris and toxic combustion products. It was also fortunate that the exploded cell stayed inside the chamber after the door was forced open. If the cell had been ejected into the room it could have caused serious facility damage by impact and possibly caused a fire in the facility.

  20. Primakoff Prize Talk: The Search for Dark Sectors

    NASA Astrophysics Data System (ADS)

    Essig, Rouven

    2015-04-01

    Dark sectors, consisting of new, light, weakly-coupled particles that do not interact with the known strong, weak, or electromagnetic forces, are a particularly interesting possibility for new physics. Nature may contain numerous dark sectors, each with their own beautiful structure, distinct particles, and forces. Examples of dark sector particles include dark photons, axions, axion-like particles, and dark matter. In many cases, the exploration of dark sectors can proceed with existing facilities and comparatively modest experiments. This talk summarizes the physics motivation for dark sectors and the exciting opportunities for experimental exploration. Particular emphasis will be given to the search for dark photons, the mediators of a broken dark U(1) gauge theory that kinetically mixes with the Standard Model hypercharge, with masses in the MeV-to-GeV range. Experimental searches include low-energy e+e- colliders, new and old high-intensity fixed-target experiments, and high-energy colliders. The talk will highlight the APEX and HPS experiments at Jefferson Lab, which are pioneering, low-cost experiments to search for dark photons in fixed target electroproduction. Over the next few years, they have the potential for a transformative discovery.

  1. Transonic high Reynolds number stability and control characteristics of a 0.015-scale remotely controlled elevon model (44-0) of the space shuttle orbiter tested in calspan 8-foot TWT (LA70)

    NASA Technical Reports Server (NTRS)

    Parrell, H.; Gamble, J. D.

    1977-01-01

    Transonic Wind Tunnel tests were run on a .015 scale model of the space shuttle orbiter vehicle in the 8-foot transonic wind tunnel. Purpose of the test program was to obtain basic shuttle aerodynamic data through a full range of elevon and aileron deflections, verification of data obtained at other facilities, and effects of Reynolds number. Tests were performed at Mach numbers from .35 to 1.20 and Reynolds numbers from 3,500,000 to 8,200,000 per foot. The high Reynolds number conditions (nominal 8,000,000/foot) were obtained using the ejector augmentation system. Angle of attack was varied from -2 to +20 degrees at sideslip angles of -2, 0, and +2 degrees. Sideslip was varied from -6 to +8 degrees at constant angles of attack from 0 to +20 degrees. Aileron settings were varied from -5 to +10 degrees at elevon deflections of -10, 0, and +10 degrees. Fixed aileron settings of 0 and 2 degrees in combination with various fixed elevon settings between -20 and +5 degrees were also run at varying angles of attack.

  2. Dynamic simulation solves process control problem in Oman

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1998-11-16

    A dynamic simulation study solved the process control problems for a Saih Rawl, Oman, gas compressor station operated by Petroleum Development of Oman (PDO). PDO encountered persistent compressor failure that caused frequent facility shutdowns, oil production deferment, and gas flaring. It commissioned MSE (Consultants) Ltd., U.K., to find a solution for the problem. Saih Rawl, about 40 km from Qarn Alam, produces oil and associated gas from a large number of low and high-pressure wells. Oil and gas are separated in three separators. The oil is pumped to Qarn Alam for treatment and export. Associated gas is compressed in twomore » parallel trains. Train K-1115 is a 350,000 standard cu m/day, four-stage reciprocating compressor driven by a fixed-speed electric motor. Train K-1120 is a 1 million standard cu m/day, four-stage reciprocating compressor driven by a fixed-speed electric motor. Train K-1120 is a 1 million standard cu m/day, four-stage centrifugal compressor driven by a variable-speed motor. The paper describes tripping and surging problems with the gas compressor and the control simplifications that solved the problem.« less

  3. Nursing Home Price and Quality Responses to Publicly Reported Quality Information

    PubMed Central

    Clement, Jan P; Bazzoli, Gloria J; Zhao, Mei

    2012-01-01

    Objective To assess whether the release of Nursing Home Compare (NHC) data affected self-pay per diem prices and quality of care. Data Sources Primary data sources are the Annual Survey of Wisconsin Nursing Homes for 2001–2003, Online Survey and Certification Reporting System, NHC, and Area Resource File. Study Design We estimated fixed effects models with robust standard errors of per diem self-pay charge and quality before and after NHC. Principal Findings After NHC, low-quality nursing homes raised their prices by a small but significant amount and decreased their use of restraints but did not reduce pressure sores. Mid-level and high-quality nursing homes did not significantly increase self-pay prices after NHC nor consistently change quality. Conclusions Our findings suggest that the release of quality information affected nursing home behavior, especially pricing and quality decisions among low-quality facilities. Policy makers should continue to monitor quality and prices for self-pay residents and scrutinize low-quality homes over time to see whether they are on a pathway to improve quality. In addition, policy makers should not expect public reporting to result in quick fixes to nursing home quality problems. PMID:22092366

  4. Production cost analysis of Euphorbia lathyris. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mendel, D.A.; Schooley, F.A.; Dickenson, R.L.

    1979-08-01

    The purpose of SRI's study was to estimate the costs of producing Euphorbia in commercial quantities in five regions of the United States, which include both irrigated and nonirrigated areas. The study assumed that a uniform crop yield could be achieved in the five regions by varying the quantities of production inputs. Therefore, the production costs estimates, which are based on fourth quarter 1978 dollars, include both fixed and variable costs for each region. Doane's Machinery Custom Rates for 1978 were used to estimate all variable costs except materials, which were estimated separately. Custom rates are determined by members ofmore » the Doane Countywide Farm Panel, a group of farmers specifically selected to represent the various sizes and types of commercial farms found throughout the country. The rates reported are the most recent rates the panel members had either paid, charged, or known for certain a second party had paid or charged. Custom rates for any particular operation include equipment operating costs (fuel, lubrication, and repairs), equipment ownership costs (depreciation, taxes, interest), as well as a labor charge for the operator. Custom rates are regionally specific and thereby assist the accuracy of this analysis. Fixed costs include land, management, and transportation of the plant material to a conversion facility. When appropriate, fixed costs were regionally specific. Changes in total production costs over future time periods were not addressed. The total estimated production costs of Euphorbia in each region were compared with production costs for corn and alfalfa in the same regions. Finally, the effects on yield and costs of changes in the production inputs were estimated.« less

  5. Clinical treatment outcomes of tuberculosis treated with the basic regimen recommended by the Brazilian National Ministry of Health using fixed-dose combination tablets in the greater metropolitan area of Goiânia, Brazil *

    PubMed Central

    Ferreira, Anna Carolina Galvão; da Silva, José Laerte Rodrigues; Conde, Marcus Barreto; Rabahi, Marcelo Fouad

    2013-01-01

    OBJECTIVE: To describe the rates of cure, treatment failure, and treatment abandonment obtained with the basic regimen recommended by the Brazilian National Ministry of Health-rifampin, isoniazid, pyrazinamide, and ethambutol for two months, followed by isoniazid and rifampin for four months-involving the use of fixed-dose combination tablets (self-administered treatment), as well as to describe adverse events and their potential impact on treatment outcomes. METHODS: This was a descriptive study based on prospective data obtained from the medical records of tuberculosis patients (≥ 18 years of age) treated with the basic regimen at either of two primary health care facilities in the greater metropolitan area of Goiânia, Brazil. RESULTS: The study sample comprised 40 tuberculosis patients. The rate of cure was 67.5%, the rate of treatment abandonment was 17.5%, and there were no cases of treatment failure. Of the 40 patients in the sample, 19 (47%) reported adverse reactions, which were mild and moderate, respectively, in 87% and 13% of the cases. It was not necessary to alter the regimen or discontinue the treatment in any of the cases evaluated. CONCLUSIONS: The rate of cure obtained with the self-administered, fixed-dose combination tablet form of the new basic regimen was similar to the historical rates of cure obtained with the previous basic regimen. The rate of treatment abandonment in our sample was much higher than that considered appropriate (up to 5%). PMID:23503489

  6. Clinical treatment outcomes of tuberculosis treated with the basic regimen recommended by the Brazilian National Ministry of Health using fixed-dose combination tablets in the greater metropolitan area of Goiânia, Brazil.

    PubMed

    Ferreira, Anna Carolina Galvão; Silva Júnior, José Laerte Rodrigues da; Conde, Marcus Barreto; Rabahi, Marcelo Fouad

    2013-01-01

    To describe the rates of cure, treatment failure, and treatment abandonment obtained with the basic regimen recommended by the Brazilian National Ministry of Health (rifampin, isoniazid, pyrazinamide, and ethambutol for two months, followed by isoniazid and rifampin for four months) involving the use of fixed-dose combination tablets (self-administered treatment), as well as to describe adverse events and their potential impact on treatment outcomes. This was a descriptive study based on prospective data obtained from the medical records of tuberculosis patients (> 18 years of age) treated with the basic regimen at either of two primary health care facilities in the greater metropolitan area of Goiânia, Brazil. The study sample comprised 40 tuberculosis patients. The rate of cure was 67.5%, the rate of treatment abandonment was 17.5%, and there were no cases of treatment failure. Of the 40 patients in the sample, 19 (47%) reported adverse reactions, which were mild and moderate, respectively, in 87% and 13% of the cases. It was not necessary to alter the regimen or discontinue the treatment in any of the cases evaluated. The rate of cure obtained with the self-administered, fixed-dose combination tablet form of the new basic regimen was similar to the historical rates of cure obtained with the previous regimen. The rate of treatment abandonment in our sample was much higher than that considered appropriate (up to 5%).

  7. Material flows of mobile phones and accessories in Nigeria: Environmental implications and sound end-of-life management options

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Osibanjo, Oladele; Nnorom, Innocent Chidi

    Presently, Nigeria is one of the fastest growing Telecom markets in the world. The country's teledensity increased from a mere 0.4 in 1999 to 10 in 2005 following the liberalization of the Telecom sector in 2001. More than 25 million new digital mobile lines have been connected by June 2006. Large quantities of mobile phones and accessories including secondhand and remanufactured products are being imported to meet the pent-up demand. This improvement in mobile telecom services resulted in the preference of mobile telecom services to fixed lines. Consequently, the contribution of fixed lines decreased from about 95% in year 2000more » to less than 10% in March 2005. This phenomenal progress in information technology has resulted in the generation of large quantities of electronic waste (e-waste) in the country. Abandoned fixed line telephone sets estimated at 120,000 units are either disposed or stockpiled. Increasing quantities of waste mobile phones estimated at 8 million units by 2007, and accessories will be generated. With no material recovery facility for e-waste and/or appropriate solid waste management infrastructure in place, these waste materials end up in open dumps and unlined landfills. These practices create the potential for the release of toxic metals and halocarbons from batteries, printed wiring boards, liquid crystal display and plastic housing units. This paper presents an overview of the developments in the Nigerian Telecom sector, the material in-flow of mobile phones, and the implications of the management practices for wastes from the Telecom sector in the country.« less

  8. Principles for timing at spallation neutron sources based on developments at LANSCE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nelson, R. O.; Merl, R. B.; Rose, C. R.

    2001-01-01

    Due to AC-power-grid frequency fluctuations, the designers for accelerator-based spallation-neutron facilities have worked to optimize the conflicting demands of accelerator and neutron chopper performance. For the first time, we are able to quantitatively access the tradeoffs between these two constraints and design or upgrade a facility to optimize total system performance using powerful new simulation techniques. We have modeled timing systems that integrate chopper controllers and chopper hardware and built new systems. Thus, at LANSCE, we now operate multiple chopper systems and the accelerator as simple slaves to a single master-timing-reference generator. Based on this experience we recommend that spallationmore » neutron sources adhere to three principles. First, timing for pulsed sources should be planned starting with extraction at a fixed phase and working backwards toward the leading edge of the beam pulse. Second, accelerator triggers and storage ring extraction commands from neutron choppers offer only marginal benefits to accelerator-based spallation sources. Third, the storage-ring RF should be phase synchronized with neutron choppers to provide extraction without the one orbit timing uncertainty.« less

  9. Development of NIRS pencil beam scanning system for carbon ion radiotherapy

    NASA Astrophysics Data System (ADS)

    Furukawa, T.; Hara, Y.; Mizushima, K.; Saotome, N.; Tansho, R.; Saraya, Y.; Inaniwa, T.; Mori, S.; Iwata, Y.; Shirai, T.; Noda, K.

    2017-09-01

    At Heavy Ion Medical Accelerator in Chiba (HIMAC) in National Institute of Radiological Sciences (NIRS), more than 9000 patients have been successfully treated by carbon ion beams since 1994. The successful results of treatments have led us to construct a new treatment facility equipped with a three-dimensional pencil beam scanning irradiation system, which is one of sophisticated techniques for cancer therapy with high energetic ion beam. This new facility comprises two treatment rooms having fixed beam lines and one treatment room having rotating gantry line. The challenge of this project is to realize treatment of a moving target by scanning irradiation. Thus, to realize this, the development of the fast scanning system is one of the most important issues in this project. After intense commissioning and quality assurance tests, the treatment with scanned ion beam was started in May 2011. After treatment of static target starts, we have developed related technologies. As a result, we can start treatment of moving target and treatment without range shifter plates since 2015. In this paper, the developments of the scanning irradiation system are described.

  10. An evaluation of concrete recycling and reuse practices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nakhjiri, K.S.; MacKinney, J.

    1997-02-01

    Nuclear facilities operated by the Department of Energy (DOE), Department of Defense (DOD), and NRC licensees contain many concrete structures that are contaminated with radioactivity. Dismantling these structures will result in significant quantities of waste materials, both contaminated and uncontaminated. Bartlett estimates the total volume of waste from demolition of concrete structures to be on the order of 4 million cubic meters, but that only 20,000 cubic meters would be contaminated with radioactivity. Other studies suggest that as much as 5% of the concrete in these facilities would be contaminated with radioactivity. While the actual quantity of contaminated material shouldmore » be fixed with greater precision, the fact that so much uncontaminated concrete exists (over 95% of the total 4 million cubic meters) suggests that a program that recycles concrete could produce substantial savings for both government agencies (DOE, DOD) and private companies (NRC licensees). This paper presents a fundamental discussion of (1) various methods of processing concrete, (2) demolition methods, especially those compatible with recycling efforts, and (3) state-of-the-art concrete dismantlement techniques.« less

  11. Experimental and computational data from a small rocket exhaust diffuser

    NASA Astrophysics Data System (ADS)

    Stephens, Samuel E.

    1993-06-01

    The Diagnostics Testbed Facility (DTF) at the NASA Stennis Space Center in Mississippi is a versatile facility that is used primarily to aid in the development of nonintrusive diagnostics for liquid rocket engine testing. The DTF consists of a fixed, 1200 lbf thrust, pressure fed, liquid oxygen/gaseous hydrogen rocket engine, and associated support systems. An exhaust diffuser has been fabricated and installed to provide subatmospheric pressures at the exit of the engine. The diffuser aerodynamic design was calculated prior to fabrication using the PARC Navier-Stokes computational fluid dynamics code. The diffuser was then fabricated and tested at the DTF. Experimental data from these tests were acquired to determine the operational characteristics of the system and to correlate the actual and predicted flow fields. The results show that a good engineering approximation of overall diffuser performance can be made using the PARC Navier-Stokes code and a simplified geometry. Correlations between actual and predicted cell pressure and initial plume expansion in the diffuser are good; however, the wall pressure profiles do not correlate as well with the experimental data.

  12. The impact of health information technology adoption by outpatient facilities on pregnancy outcomes.

    PubMed

    Deily, Mary E; Hu, Tianyan; Terrizzi, Sabrina; Chou, Shin-Yi; Meyerhoefer, Chad D

    2013-02-01

    Examine whether health information technology (HIT) at nonhospital facilities (NHFs) improves health outcomes and decreases resource use at hospitals within the same heath care network, and whether the impact of HIT varies as providers gain experience using the technologies. Administrative claims data on 491,832 births in Pennsylvania during 1998-2004 from the Pennsylvania Health Care Cost Containment Council and HIT applications data from the Dorenfest Institute. Fixed-effects regression analysis of the impact of HIT at NHFs on adverse birth outcomes and resource use. Greater use of clinical HIT applications by NHFs is associated with reduced incidence of obstetric trauma and preventable complications, as well as longer lengths of stay. In addition, the beneficial effects of HIT increase the longer that technologies have been in use. However, we find no consistent evidence on whether or how nonclinical HIT in NHFs affects either resource use or health outcomes. Clinical HIT applications at NHFs may reduce the likelihood of adverse birth outcomes, particularly after physicians and staff gain experience using the technologies. © Health Research and Educational Trust.

  13. Hydro-scaling of DT implosions on the National Ignition Facility

    NASA Astrophysics Data System (ADS)

    Patel, Pravesh; Spears, Brian; Clark, Dan

    2017-10-01

    Recent implosion experiments on the National Ignition Facility (NIF) exceed 50 kJ in fusion yield and exhibit yield amplifications of >2.5-3x due to alpha-particle self-heating of the hot-spot. Two methods to increase the yield are (i) to improve the implosion quality, or stagnation pressure, at fixed target scale (by increasing implosion velocity, reducing 3D effects, etc.), and (ii) to hydrodynamically scale the capsule and absorbed energy. In the latter case the stagnation pressure remains constant, but the yield-in the absence of alpha-heating-increases as Y S 4 . 5 , where the capsule radius is increased by S, and the absorbed energy by S3 . With alpha-heating the increase with scale is considerably stronger. We present projections in the performance of current DT experiments, and the extrapolations to ignition, based on applying hydro-scaling theory and accounting for the effect of alpha-heating. This work was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344.

  14. Supply chain network design problem for a new market opportunity in an agile manufacturing system

    NASA Astrophysics Data System (ADS)

    Babazadeh, Reza; Razmi, Jafar; Ghodsi, Reza

    2012-08-01

    The characteristics of today's competitive environment, such as the speed with which products are designed, manufactured, and distributed, and the need for higher responsiveness and lower operational cost, are forcing companies to search for innovative ways to do business. The concept of agile manufacturing has been proposed in response to these challenges for companies. This paper copes with the strategic and tactical level decisions in agile supply chain network design. An efficient mixed-integer linear programming model that is able to consider the key characteristics of agile supply chain such as direct shipments, outsourcing, different transportation modes, discount, alliance (process and information integration) between opened facilities, and maximum waiting time of customers for deliveries is developed. In addition, in the proposed model, the capacity of facilities is determined as decision variables, which are often assumed to be fixed. Computational results illustrate that the proposed model can be applied as a power tool in agile supply chain network design as well as in the integration of strategic decisions with tactical decisions.

  15. The Impact of Health Information Technology Adoption by Outpatient Facilities on Pregnancy Outcomes

    PubMed Central

    Deily, Mary E; Hu, Tianyan; Terrizzi, Sabrina; Chou, Shin-Yi; Meyerhoefer, Chad D

    2013-01-01

    Objective Examine whether health information technology (HIT) at nonhospital facilities (NHFs) improves health outcomes and decreases resource use at hospitals within the same heath care network, and whether the impact of HIT varies as providers gain experience using the technologies. Data Sources Administrative claims data on 491,832 births in Pennsylvania during 1998–2004 from the Pennsylvania Health Care Cost Containment Council and HIT applications data from the Dorenfest Institute. Study Design Fixed-effects regression analysis of the impact of HIT at NHFs on adverse birth outcomes and resource use. Principal Findings Greater use of clinical HIT applications by NHFs is associated with reduced incidence of obstetric trauma and preventable complications, as well as longer lengths of stay. In addition, the beneficial effects of HIT increase the longer that technologies have been in use. However, we find no consistent evidence on whether or how nonclinical HIT in NHFs affects either resource use or health outcomes. Conclusions Clinical HIT applications at NHFs may reduce the likelihood of adverse birth outcomes, particularly after physicians and staff gain experience using the technologies. PMID:22742682

  16. Goddard Space Flight Center (GSFC) Flight Dynamics Facility (FDF) calibration of the Upper Atmosphere Research Satellite (UARS) sensors

    NASA Technical Reports Server (NTRS)

    Hashmall, J.; Garrick, J.

    1993-01-01

    Flight Dynamics Facility (FDF) responsibilities for calibration of Upper Atmosphere Research Satellite (UARS) sensors included alignment calibration of the fixed-head star trackers (FHST's) and the fine Sun sensor (FSS), determination of misalignments and scale factors for the inertial reference units (IRU's), determination of biases for the three-axis magnetometers (TAM's) and Earth sensor assemblies (ESA's), determination of gimbal misalignments of the Solar/Stellar Pointing Platform (SSPP), and field-of-view calibration for the FSS's mounted both on the Modular Attitude Control System (MACS) and on the SSPP. The calibrations, which used a combination of new and established algorithms, gave excellent results. Alignment calibration results markedly improved the accuracy of both ground and onboard Computer (OBC) attitude determination. SSPP calibration results allowed UARS to identify stars in the period immediately after yaw maneuvers, removing the delay required for the OBC to reacquire its fine pointing attitude mode. SSPP calibration considerably improved the pointing accuracy of the attached science instrument package. This paper presents a summary of the methods used and the results of all FDF UARS sensor calibration.

  17. The Nuclotron-based Ion Collider Facility Project. The Physics Programme for the Multi-Purpose Detector

    NASA Astrophysics Data System (ADS)

    Geraksiev, N. S.; MPD Collaboration

    2018-05-01

    The Nuclotron-based Ion Collider fAcility (NICA) is a new accelerator complex being constructed at the Joint Institute for Nuclear Research (JINR). The general objective of the project is to provide beams for the experimental study of hot and dense strongly interacting QCD matter. The heavy ion programme includes two planned detectors: BM@N (Baryonic Matter at Nuclotron) a fixed target experiment with extracted Nuclotron beams; and MPD (MultiPurpose Detector) a collider mode experiment at NICA. The accelerated particles can range from protons and light nuclei to gold ions. Beam energies will span\\sqrt{s}=12-27 GeV with luminosity L ≥ 1 × 1030 cm‑2s‑1 and \\sqrt{{s}NN}=4-11 GeV and average luminosity L = 1 × 1027cm‑2 s ‑1(for 197Au79+), respectively. A third experiment for spin physics is planned with the SPD (Spin Physics Detector) at the NICA collider in polarized beams mode. A brief overview of the MPD is presented along with several observables in the MPD physics programme.

  18. Do financial incentives of introducing case mix reimbursement increase feeding tube use in nursing home residents?

    PubMed

    Teno, Joan M; Feng, Zhanlian; Mitchell, Susan L; Kuo, Sylvia; Intrator, Orna; Mor, Vincent

    2008-05-01

    To determine whether adoption of Medicaid case mix reimbursement is associated with greater prevalence of feeding tube use in nursing home (NH) residents. Secondary analysis of longitudinal administrative data about the prevalence of feeding tube insertion and surveys of states' adoption of case mix reimbursement. NHs in the United States. NH residents at the time of NH inspection between 1993 and 2004. Facility prevalence of feeding tubes reported at the state inspection of NHs reported in the Online Survey, Certification and Reporting database and interviews with state policy makers regarding the adoption of case mix reimbursement. Between 1993 and 2004, 16 states adopted Resource Utilization Group case mix reimbursement. States varied in the prevalence of feeding tubes in their NHs. Although the use of feeding tube increased substantially over the years of the study, once temporal trends and facility fixed effects were accounted for, case mix reimbursement was not associated with greater prevalence of feeding tube use. The adoption of Medicaid case mix reimbursement was not associated with an increase in the prevalence of feeding tube use.

  19. Asymmetrically cut crystal pair as x-ray magnifier for imaging at high intensity laser facilitiesa)

    NASA Astrophysics Data System (ADS)

    Szabo, C. I.; Feldman, U.; Seely, J. F.; Curry, J. J.; Hudson, L. T.; Henins, A.

    2010-10-01

    The potential of an x-ray magnifier prepared from a pair of asymmetrically cut crystals is studied to explore high energy x-ray imaging capabilities at high intensity laser facilities. OMEGA-EP and NIF when irradiating mid and high Z targets can be a source of high-energy x-rays whose production mechanisms and use as backlighters are a subject of active research. This paper studies the properties and potential of existing asymmetric cut crystal pairs from the National Institute of Standards and Technology (NIST) built in a new enclosure for imaging x-ray sources. The technique of the x-ray magnifier has been described previously. This new approach is aimed to find a design that could be used at laser facilities by magnifying the x-ray source into a screen far away from the target chamber center, with fixed magnification defined by the crystals' lattice spacing and the asymmetry angles. The magnified image is monochromatic and the imaging wavelength is set by crystal asymmetry and incidence angles. First laboratory results are presented and discussed.

  20. Operation of large RF sources for H-: Lessons learned at ELISE

    NASA Astrophysics Data System (ADS)

    Fantz, U.; Wünderlich, D.; Heinemann, B.; Kraus, W.; Riedl, R.

    2017-08-01

    The goal of the ELISE test facility is to demonstrate that large RF-driven negative ion sources (1 × 1 m2 source area with 360 kW installed RF power) can achieve the parameters required for the ITER beam sources in terms of current densities and beam homogeneity at a filling pressure of 0.3 Pa for pulse lengths of up to one hour. With the experience in operation of the test facility, the beam source inspection and maintenance as well as with the results of the achieved source performance so far, conclusions are drawn for commissioning and operation of the ITER beam sources. Addressed are critical technical RF issues, extrapolations to the required RF power, Cs consumption and Cs ovens, the need of adjusting the magnetic filter field strength as well as the temporal dynamic and spatial asymmetry of the co-extracted electron current. It is proposed to relax the low pressure limit to 0.4 Pa and to replace the fixed electron-to-ion ratio by a power density limit for the extraction grid. This would be highly beneficial for controlling the co-extracted electrons.

  1. KSC-07pd1206

    NASA Image and Video Library

    2007-05-15

    KENNEDY SPACE CENTER, FLA. -- The locomotive and rail cars carrying solid rocket booster motor segments and two aft exit cone segments roll to the Rotation, Processing and Surge Facility in Kennedy Space Center's Launch Complex 39 Area. The main facility is used for solid rocket motor receiving, rotation and inspection, and supports aft booster buildup. When live solid rocket motor segments arrive at the processing facility, they are positioned under one of the cranes. Handling slings are then attached to and remove the railcar cover. The segment is inspected while it remains horizontal. The two overhead cranes hoist the segment, rotate it to a vertical position and place it on a fixed stand. The aft handling ring is then removed. The segment is hoisted again and lowered onto a transportation and storage pallet, and the forward handling ring is removed to allow inspections. It is then transported to one of the surge buildings and temporarily stored until it is needed for booster stacking in the VAB. While enroute, solid rocket motor segments were involved in a derailment in Alabama. The rail cars carrying these segments remained upright and were undamaged. An inspection determined these segment cars could continue on to Florida. The segments themselves will undergo further evaluation at Kennedy before they are cleared for flight. Other segments involved in the derailment will be returned to a plant in Utah for further evaluation. Photo credit: NASA/George Shelton

  2. Ecological Realism of US EPA Experimental Stream Facility ...

    EPA Pesticide Factsheets

    The USEPA’s Experimental Stream Facility (ESF) conducts meso-scale ecotoxicology studies that account for both structural and functional responses of whole stream communities to contaminants or other stressors. The 16 mesocosms of ESF are indoors and consist of a tiled run section (0.152 m W x 4.268 m L x 0.105 m D) that widens to a gravel riffle section (0.305 m W x 4.268 m L x 0.19 m D). They are intermediate size among studies reporting stream mesocosm results. Their set-up is unique for their size, with a high degree of engineering controls for continuous flow-through dose-response designs, yet fixed, chronic exposures to contaminants under conditions that quantifiably mimic real stream riffle/run habitat with consistent upstream renewal. With fifty standard operating procedures serving ESF studies, the background and boundary condition information is collected to determine the realism critical to the field relevance of the results. Parallel ex situ and in situ single species exposure formats including fish survival and fecundity metrics are also included. With this framework studies at ESF provide scientifically defensible evaluation of proposed aquatic life criteria. This presentation discusses the relevance and realism of USEPA's mesocosms studies conducted using the Experimental Stream Facility in Milford, OH within the context of understanding the role meso-scale results can play in validating aquatic life criteria for streams and, more generally, man

  3. Multi-keV X-ray area source intensity at SGII laser facility

    NASA Astrophysics Data System (ADS)

    Wang, Rui-rong; An, Hong-hai; Xie, Zhi-yong; Wang, Wei

    2018-05-01

    Experiments for investigating the feasibility of multi-keV backlighters for several different metallic foil targets were performed at the Shenguang II (SGII) laser facility in China. Emission spectra in the energy range of 1.65-7.0 keV were measured with an elliptically bent crystal spectrometer, and the X-ray source size was measured with a pinhole camera. The X-ray intensity near 4.75 keV and the X-ray source size for titanium targets at different laser intensity irradiances were studied. By adjusting the total laser energy at a fixed focal spot size, laser intensity in the range of 1.5-5.0 × 1015 W/cm2, was achieved. The results show that the line emission intensity near 4.75 keV and the X-ray source size are dependent on the laser intensity and increase as the laser intensity increases. However, an observed "peak" in the X-ray intensity near 4.75 keV occurs at an irradiance of 4.0 × 1015 W/cm2. For the employed experimental conditions, it was confirmed that the laser intensity could play a significant role in the development of an efficient multi-keV X-ray source. The experimental results for titanium indicate that the production of a large (˜350 μm in diameter) intense backlighter source of multi-keV X-rays is feasible at the SGII facility.

  4. Progress in Decommissioning the Humboldt Bay Power Plant - 13604

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rod, Kerry; Shelanskey, Steven K.; Kristofzski, John

    Decommissioning of the Pacific Gas and Electric (PG and E) Company Humboldt Bay Power Plant (HBPP) Unit 3 nuclear facility has now, after more than three decades of SAFSTOR and initial decommissioning work, transitioned to full-scale decommissioning. Decommissioning activities to date have been well orchestrated and executed in spite of an extremely small work site with space constricted even more by other concurrent on-site major construction projects including the demolition of four fossil units, construction of a new generating station and 60 KV switchyard upgrade. Full-scale decommissioning activities - now transitioning from Plant Systems Removal (PG and E self-perform) tomore » Civil Works Projects (contractor performed) - are proceeding in a safe, timely, and cost effective manner. As a result of the successful decommissioning work to date (approximately fifty percent completed) and the intense planning and preparations for the remaining work, there is a high level of confidence for completion of all HBPP Unit 3 decommissions activities in 2018. Strategic planning and preparations to transition into full-scale decommissioning was carried out in 2008 by a small, highly focused project team. This planning was conducted concurrent with other critical planning requirements such as the loading of spent nuclear fuel into dry storage at the Independent Spent Fuel Storage Installation (ISFSI) finishing December 2008. Over the past four years, 2009 through 2012, the majority of decommissioning work has been installation of site infrastructure and removal of systems and components, known as the Plant System Removal Phase, where work scope was dynamic with significant uncertainty, and it was self-performed by PG and E. As HBPP Decommissioning transitions from the Plant System Removal Phase to the Civil Works Projects Phase, where work scope is well defined, a contracting plan similar to that used for Fossil Decommissioning will be implemented. Award of five major work scopes in various stages of development are planned as they include: Turbine Building Demolition, Nuclear Facilities Demolition and Excavation, Intake and Discharge Canal Remediation, Office Facility Demobilization, and Final Site Restoration. Benefits realized by transitioning to the Civil Works Projects Phase with predominant firm fixed-price/fixed unit price contracting include single civil works contractor who can coordinate concrete shaving, liner removal, structural removal, and other demolition activities; streamline financial control; reduce PG and E overhead staffing; and provide a specialized Bidder Team with experience from other similar projects. (authors)« less

  5. Combustion

    NASA Technical Reports Server (NTRS)

    Bulzan, Dan

    2007-01-01

    An overview of the emissions related research being conducted as part of the Fundamental Aeronautics Subsonics Fixed Wing Project is presented. The overview includes project metrics, milestones, and descriptions of major research areas. The overview also includes information on some of the emissions research being conducted under NASA Research Announcements. Objective: Development of comprehensive detailed and reduced kinetic mechanisms of jet fuels for chemically-reacting flow modeling. Scientific Challenges: 1) Developing experimental facilities capable of handling higher hydrocarbons and providing benchmark combustion data. 2) Determining and understanding ignition and combustion characteristics, such as laminar flame speeds, extinction stretch rates, and autoignition delays, of jet fuels and hydrocarbons relevant to jet surrogates. 3) Developing comprehensive kinetic models for jet fuels.

  6. Development of economical improved thick film solar cell contact

    NASA Technical Reports Server (NTRS)

    Ross, B.

    1979-01-01

    Metal screened electrodes were investigated with base metal pastes and silver systems being focused upon. Contact resistance measurements were refined. A facility allowing fixing in hydrogen and other atmospheres was acquired. Several experiments were made applying screenable pastes to solar cells. Doping investigations emphasized eutectic alloys reduced to powders. Metal systems were reviewed and base metal experiments were done with nickel and copper using lead and tin as the frit metals. Severe adhesion problems were experienced with hydrogen atmospheres in all metal systems. A two step firing schedule was devised. Aluminum-silicon and aluminum-germanium eutectic doping additions to copper pastes were tried on 2 1/4 in diameter solar cell back contacts, both with good results.

  7. Micropore Geometry Manipulation by Macroscopic Deformation Based on Shape Memory Effect in Porous PLLA Membrane and its Enhanced Separation Performance.

    PubMed

    Zhao, Jingxin; Yang, Qiucheng; Wang, Tao; Wang, Lian; You, Jichun; Li, Yongjin

    2017-12-20

    An effective strategy to tailor the microporous structures has been developed based on the shape memory effect in porous poly(l-lactic acid) membranes in which tiny crystals and amorphous matrix play the roles of shape-fixed phase and reversible-phase, respectively. Our results indicate that not only PLLA membranes but micropores exhibit shape memory properties. The proportional deformations on two scales have been achieved by uniaxial or biaxial tension, providing a facile way to manipulate continuously the size and the orientation degree of pores on microscale. The enhanced separation performance has been validated by taking polystyrene colloids with varying diameters as an example.

  8. Validation of Infrared Azimuthal Model as Applied to GOES Data Over the ARM SGP

    NASA Technical Reports Server (NTRS)

    Gambheer, Arvind V.; Doelling, David R.; Spangenberg, Douglas A.; Minnis, Patrick

    2004-01-01

    The goal of this research is to identify and reduce the GOES-8 IR temperature biases, induced by a fixed geostationary position, during the course of a day. In this study, the same CERES LW window channel model is applied to GOES-8 IR temperatures during clear days over the Atmospheric Radiation Measurement-Southern Great Plains Central Facility (SCF). The model-adjusted and observed IR temperatures are compared with topof- the-atmosphere (TOA) estimated temperatures derived from a radiative transfer algorithm based on the atmospheric profile and surface radiometer measurements. This algorithm can then be incorporated to derive more accurate Ts from real-time satellite operational products.

  9. Rapid identification of Prototheca species by the API 20C system.

    PubMed Central

    Padhye, A A; Baker, J G; D'Amato, R F

    1979-01-01

    The conventional auxanographic method of testing for the assimilation of carbohydrates and alcohols by the various species of Prototheca requires at least 2 weeks of incubation at 25 to 30 degrees C before definitive results are obtained. Even though Prototheca spp., in culture as well as in fixed tissues, can be identified more rapidly by fluorescent-antibody techniques in which species-specific reagents are used, such diagnostic facilities and reagents are not available in most diagnostic laboratories. The API 20C clinical yeast identification system, a commercially available ready-to-use micromethod, was found to permit the definitive identification of P. stagnora, P. wickerhamii, and P. zopfii within 4 days. Images PMID:393722

  10. Effects of independent variation of Mach and Reynolds numbers on the low-speed aerodynamic characteristics of the NACA 0012 airfoil section

    NASA Technical Reports Server (NTRS)

    Ladson, Charles L.

    1988-01-01

    A comprehensive data base is given for the low speed aerodynamic characteristics of the NACA 0012 airfoil section. The Langley low-turbulence pressure tunnel is the facility used to obtain the data. Included in the report are the effects of Mach number and Reynolds number and transition fixing on the aerodynamic characteristics. Presented are also comparisons of some of the results with previously published data and with theoretical estimates. The Mach number varied from 0.05 to 0.36. The Reynolds number, based on model chord, varied from 3 x 10 to the 6th to 12 x 10 to the 6th power.

  11. Modeling of information flows in natural gas storage facility

    NASA Astrophysics Data System (ADS)

    Ranjbari, Leyla; Bahar, Arifah; Aziz, Zainal Abdul

    2013-09-01

    The paper considers the natural-gas storage valuation based on the information-based pricing framework of Brody-Hughston-Macrina (BHM). As opposed to many studies which the associated filtration is considered pre-specified, this work tries to construct the filtration in terms of the information provided to the market. The value of the storage is given by the sum of the discounted expectations of the cash flows under risk-neutral measure, conditional to the constructed filtration with the Brownian bridge noise term. In order to model the flow of information about the cash flows, we assume the existence of a fixed pricing kernel with liquid, homogenous and incomplete market without arbitrage.

  12. Flight data processing with the F-8 adaptive algorithm

    NASA Technical Reports Server (NTRS)

    Hartmann, G.; Stein, G.; Petersen, K.

    1977-01-01

    An explicit adaptive control algorithm based on maximum likelihood estimation of parameters has been designed for NASA's DFBW F-8 aircraft. To avoid iterative calculations, the algorithm uses parallel channels of Kalman filters operating at fixed locations in parameter space. This algorithm has been implemented in NASA/DFRC's Remotely Augmented Vehicle (RAV) facility. Real-time sensor outputs (rate gyro, accelerometer and surface position) are telemetered to a ground computer which sends new gain values to an on-board system. Ground test data and flight records were used to establish design values of noise statistics and to verify the ground-based adaptive software. The software and its performance evaluation based on flight data are described

  13. Study on the bearing capacity of embedded chute on shield tunnel segment

    NASA Astrophysics Data System (ADS)

    Fanzhen, Zhang; Jie, Bu; Zhibo, Su; Qigao, Hu

    2018-05-01

    The method of perforation and steel implantation is often used to fix and install pipeline, cables and other facilities in the shield tunnel, which would inevitably do damage to the precast segments. In order to reduce the damage and the resulting safety and durability problems, embedded chute was set at the equipment installation in one shield tunnel. Finite element models of segment concrete and steel are established in this paper. When water-soil pressure calculated separately and calculated together, the mechanical property of segment is studied. The bearing capacity and deformation of segment are analysed before and after embedding the chute. Research results provide a reference for similar shield tunnel segment engineering.

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carlsbad Field Office

    The Performance Demonstration Program (PDP) for headspace gases distributes blind audit samples in a gas matrix for analysis of volatile organic compounds (VOCs). Participating measurement facilities (i.e., fixed laboratories, mobile analysis systems, and on-line analytical systems) are located across the United States. Each sample distribution is termed a PDP cycle. These evaluation cycles provide an objective measure of the reliability of measurements performed for transuranic (TRU) waste characterization. The primary documents governing the conduct of the PDP are the Quality Assurance Program Document (QAPD) (DOE/CBFO-94-1012) and the Waste Isolation Pilot Plant (WIPP) Waste Analysis Plan (WAP) contained in the Hazardousmore » Waste Facility Permit (NM4890139088-TSDF) issued by the New Mexico Environment Department (NMED). The WAP requires participation in the PDP; the PDP must comply with the QAPD and the WAP. This plan implements the general requirements of the QAPD and the applicable requirements of the WAP for the Headspace Gas (HSG) PDP. Participating measurement facilities analyze blind audit samples of simulated TRU waste package headspace gases according to the criteria set by this PDP Plan. Blind audit samples (hereafter referred to as PDP samples) are used as an independent means to assess each measurement facility’s compliance with the WAP quality assurance objectives (QAOs). To the extent possible, the concentrations of VOC analytes in the PDP samples encompass the range of concentrations anticipated in actual TRU waste package headspace gas samples. Analyses of headspace gases are required by the WIPP to demonstrate compliance with regulatory requirements. These analyses must be performed by measurement facilities that have demonstrated acceptable performance in this PDP. These analyses are referred to as WIPP analyses and the TRU waste package headspace gas samples on which they are performed are referred to as WIPP samples in this document. Participating measurement facilities must analyze PDP samples using the same procedures used for routine waste characterization analyses of WIPP samples.« less

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carlsbad Field Office

    The Performance Demonstration Program (PDP) for headspace gases distributes sample gases of volatile organic compounds (VOCs) for analysis. Participating measurement facilities (i.e., fixed laboratories, mobile analysis systems, and on-line analytical systems) are located across the United States. Each sample distribution is termed a PDP cycle. These evaluation cycles provide an objective measure of the reliability of measurements performed for transuranic (TRU) waste characterization. The primary documents governing the conduct of the PDP are the Quality Assurance Program Document (QAPD) (DOE/CBFO-94-1012) and the Waste Isolation Pilot Plant (WIPP) Waste Analysis Plan (WAP) contained in the Hazardous Waste Facility Permit (NM4890139088-TSDF) issuedmore » by the New Mexico Environment Department (NMED). The WAP requires participation in the PDP; the PDP must comply with the QAPD and the WAP. This plan implements the general requirements of the QAPD and the applicable requirements of the WAP for the Headspace Gas (HSG) PDP. Participating measurement facilities analyze blind audit samples of simulated TRU waste package headspace gases according to the criteria set by this PDP Plan. Blind audit samples (hereafter referred to as PDP samples) are used as an independent means to assess each measurement facility’s compliance with the WAP quality assurance objectives (QAOs). To the extent possible, the concentrations of VOC analytes in the PDP samples encompass the range of concentrations anticipated in actual TRU waste package headspace gas samples. Analyses of headspace gases are required by the WIPP to demonstrate compliance with regulatory requirements. These analyses must be performed by measurement facilities that have demonstrated acceptable performance in this PDP. These analyses are referred to as WIPP analyses and the TRU waste package headspace gas samples on which they are performed are referred to as WIPP samples in this document. Participating measurement facilities must analyze PDP samples using the same procedures used for routine waste characterization analyses of WIPP samples.« less

  16. OPEN AIR DEMOLITION OF FACILITIES HIGHLY CONTAMINATED WITH PLUTONIUM

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    LLOYD, E.R.

    2007-05-31

    The demolition of highly contaminated plutonium buildings usually is a long and expensive process that involves decontaminating the building to near free- release standards and then using conventional methods to remove the structure. It doesn't, however, have to be that way. Fluor has torn down buildings highly contaminated with plutonium without excessive decontamination. By removing the select source term and fixing the remaining contamination on the walls, ceilings, floors, and equipment surfaces; open-air demolition is not only feasible, but it can be done cheaper, better (safer), and faster. Open-air demolition techniques were used to demolish two highly contaminated buildings tomore » slab-on-grade. These facilities on the Department of Energy's Hanford Site were located in, or very near, compounds of operating nuclear facilities that housed hundreds of people working on a daily basis. To keep the facilities operating and the personnel safe, the projects had to be creative in demolishing the structures. Several key techniques were used to control contamination and keep it within the confines of the demolition area: spraying fixatives before demolition; applying fixative and misting with a fine spray of water as the buildings were being taken down; and demolishing the buildings in a controlled and methodical manner. In addition, detailed air-dispersion modeling was done to establish necessary building and meteorological conditions and to confirm the adequacy of the proposed methods. Both demolition projects were accomplished without any spread of contamination outside the modest buffer areas established for contamination control. Furthermore, personnel exposure to radiological and physical hazards was significantly reduced by using heavy equipment rather than ''hands on'' techniques.« less

  17. Proton Therapy Facility Planning From a Clinical and Operational Model.

    PubMed

    Das, Indra J; Moskvin, Vadim P; Zhao, Qingya; Cheng, Chee-Wai; Johnstone, Peter A

    2015-10-01

    This paper provides a model for planning a new proton therapy center based on clinical data, referral pattern, beam utilization and technical considerations. The patient-specific data for the depth of targets from skin in each beam angle were reviewed at our center providing megavoltage photon external beam and proton beam therapy respectively. Further, data on insurance providers, disease sites, treatment depths, snout size and the beam angle utilization from the patients treated at our proton facility were collected and analyzed for their utilization and their impact on the facility cost. The most common disease sites treated at our center are head and neck, brain, sarcoma and pediatric malignancies. From this analysis, it is shown that the tumor depth from skin surface has a bimodal distribution (peak at 12 and 26 cm) that has significant impact on the maximum proton energy, requiring the energy in the range of 130-230 MeV. The choice of beam angles also showed a distinct pattern: mainly at 90° and 270°; this indicates that the number of gantries may be minimized. Snout usage data showed that 70% of the patients are treated with 10 cm snouts. The cost of proton beam therapy depends largely on the type of machine, maximum beam energy and the choice of gantry versus fixed beam line. Our study indicates that for a 4-room center, only two gantry rooms could be needed at the present pattern of the patient cohorts, thus significantly reducing the initial capital cost. In the USA, 95% and 100% of patients can be treated with 200 and 230 MeV proton beam respectively. Use of multi-leaf collimators and pencil beam scanning may further reduce the operational cost of the facility. © The Author(s) 2014.

  18. Good Manufacturing Practices (GMP) manufacturing of advanced therapy medicinal products: a novel tailored model for optimizing performance and estimating costs.

    PubMed

    Abou-El-Enein, Mohamed; Römhild, Andy; Kaiser, Daniel; Beier, Carola; Bauer, Gerhard; Volk, Hans-Dieter; Reinke, Petra

    2013-03-01

    Advanced therapy medicinal products (ATMP) have gained considerable attention in academia due to their therapeutic potential. Good Manufacturing Practice (GMP) principles ensure the quality and sterility of manufacturing these products. We developed a model for estimating the manufacturing costs of cell therapy products and optimizing the performance of academic GMP-facilities. The "Clean-Room Technology Assessment Technique" (CTAT) was tested prospectively in the GMP facility of BCRT, Berlin, Germany, then retrospectively in the GMP facility of the University of California-Davis, California, USA. CTAT is a two-level model: level one identifies operational (core) processes and measures their fixed costs; level two identifies production (supporting) processes and measures their variable costs. The model comprises several tools to measure and optimize performance of these processes. Manufacturing costs were itemized using adjusted micro-costing system. CTAT identified GMP activities with strong correlation to the manufacturing process of cell-based products. Building best practice standards allowed for performance improvement and elimination of human errors. The model also demonstrated the unidirectional dependencies that may exist among the core GMP activities. When compared to traditional business models, the CTAT assessment resulted in a more accurate allocation of annual expenses. The estimated expenses were used to set a fee structure for both GMP facilities. A mathematical equation was also developed to provide the final product cost. CTAT can be a useful tool in estimating accurate costs for the ATMPs manufactured in an optimized GMP process. These estimates are useful when analyzing the cost-effectiveness of these novel interventions. Copyright © 2013 International Society for Cellular Therapy. Published by Elsevier Inc. All rights reserved.

  19. Commercial low-Btu coal-gasification plant. Feasibility study: General Refractories Company, Florence, Kentucky. Volume I. Project summary. [Wellman-Galusha

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    1981-11-01

    In response to a 1980 Department of Energy solicitation, the General Refractories Company submitted a Proposal for a feasibility study of a low Btu gasification facility for its Florence, KY plant. The proposed facility would substitute low Btu gas from a fixed bed gasifier for natural gas now used in the manufacture of insulation board. The Proposal from General Refractories was prompted by a concern over the rising costs of natural gas, and the anticipation of a severe increase in fuel costs resulting from deregulation. The proposed feasibility study is defined. The intent is to provide General Refractories with themore » basis upon which to determine the feasibility of incorporating such a facility in Florence. To perform the work, a Grant for which was awarded by the DOE, General Refractories selected Dravo Engineers and Contractors based upon their qualifications in the field of coal conversion, and the fact that Dravo has acquired the rights to the Wellman-Galusha technology. The LBG prices for the five-gasifier case are encouraging. Given the various natural gas forecasts available, there seems to be a reasonable possibility that the five-gasifier LBG prices will break even with natural gas prices somewhere between 1984 and 1989. General Refractories recognizes that there are many uncertainties in developing these natural gas forecasts, and if the present natural gas decontrol plan is not fully implemented some financial risks occur in undertaking the proposed gasification facility. Because of this, General Refractories has decided to wait for more substantiating evidence that natural gas prices will rise as is now being predicted.« less

  20. Measuring movement towards improved emergency obstetric care in rural Kenya with implementation of the PRONTO simulation and team training program.

    PubMed

    Dettinger, Julia C; Kamau, Stephen; Calkins, Kimberly; Cohen, Susanna R; Cranmer, John; Kibore, Minnie; Gachuno, Onesmus; Walker, Dilys

    2018-02-01

    As the proportion of facility-based births increases, so does the need to ensure that mothers and their newborns receive quality care. Developing facility-oriented obstetric and neonatal training programs grounded in principles of teamwork utilizing simulation-based training for emergency response is an important strategy for improving the quality care. This study uses 3 dimensions of the Kirkpatrick Model to measure the impact of PRONTO International (PRONTO) simulation-based training as part of the Linda Afya ya Mama na Mtoto (LAMMP, Protect the Health of mother and child) in Kenya. Changes in knowledge of obstetric and neonatal emergency response, self-efficacy, and teamwork were analyzed using longitudinal, fixed-effects, linear regression models. Participants from 26 facilities participated in the training between 2013 and 2014. The results demonstrate improvements in knowledge, self-efficacy, and teamwork self-assessment. When comparing pre-Module I scores with post-training scores, improvements range from 9 to 24 percentage points (p values < .0001 to .026). Compared to baseline, post-Module I and post-Module II (3 months later) scores in these domains were similar. The intervention not only improved participant teamwork skills, obstetric and neonatal knowledge, and self-efficacy but also fostered sustained changes at 3 months. The proportion of facilities achieving self-defined strategic goals was high: 95.8% of the 192 strategic goals. Participants rated the PRONTO intervention as extremely useful, with an overall score of 1.4 out of 5 (1, extremely useful; 5, not at all useful). Evaluation of how these improvements affect maternal and perinatal clinical outcomes is forthcoming. © 2018 John Wiley & Sons Ltd.

Top