Sample records for facility backup central

  1. Onsite and Electric Backup Capabilities at Critical Infrastructure Facilities in the United States

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Phillips, Julia A.; Wallace, Kelly E.; Kudo, Terence Y.

    2016-04-01

    The following analysis, conducted by Argonne National Laboratory’s (Argonne’s) Risk and Infrastructure Science Center (RISC), details an analysis of electric power backup of national critical infrastructure as captured through the Department of Homeland Security’s (DHS’s) Enhanced Critical Infrastructure Program (ECIP) Initiative. Between January 1, 2011, and September 2014, 3,174 ECIP facility surveys have been conducted. This study focused first on backup capabilities by infrastructure type and then expanded to infrastructure type by census region.

  2. Emergency and backup power supplies at Department of Energy facilities: Augmented Evaluation Team -- Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    This report documents the results of the Defense Programs (DP) Augmented Evaluation Team (AET) review of emergency and backup power supplies (i.e., generator, uninterruptible power supply, and battery systems) at DP facilities. The review was conducted in response to concerns expressed by former Secretary of Energy James D. Watkins over the number of incidents where backup power sources failed to provide electrical power during tests or actual demands. The AET conducted a series of on-site reviews for the purpose of understanding the design, operation, maintenance, and safety significance of emergency and backup power (E&BP) supplies. The AET found that themore » quality of programs related to maintenance of backup power systems varies greatly among the sites visited, and often among facilities at the same site. No major safety issues were identified. However, there are areas where the AET believes the reliability of emergency and backup power systems can and should be improved. Recommendations for improving the performance of E&BP systems are provided in this report. The report also discusses progress made by Management and Operating (M&O) contractors to improve the reliability of backup sources used in safety significant applications. One area that requires further attention is the analysis and understanding of the safety implications of backup power equipment. This understanding is needed for proper graded-approach implementation of Department of Energy (DOE) Orders, and to help ensure that equipment important to the safety of DOE workers, the public, and the environment is identified, classified, recognized, and treated as such by designers, users, and maintainers. Another area considered important for improving E&BP system performance is the assignment of overall ownership responsibility and authority for ensuring that E&BP equipment performs adequately and that reliability and availability are maintained at acceptable levels.« less

  3. The amino acid's backup bone - storage solutions for proteomics facilities.

    PubMed

    Meckel, Hagen; Stephan, Christian; Bunse, Christian; Krafzik, Michael; Reher, Christopher; Kohl, Michael; Meyer, Helmut Erich; Eisenacher, Martin

    2014-01-01

    Proteomics methods, especially high-throughput mass spectrometry analysis have been continually developed and improved over the years. The analysis of complex biological samples produces large volumes of raw data. Data storage and recovery management pose substantial challenges to biomedical or proteomic facilities regarding backup and archiving concepts as well as hardware requirements. In this article we describe differences between the terms backup and archive with regard to manual and automatic approaches. We also introduce different storage concepts and technologies from transportable media to professional solutions such as redundant array of independent disks (RAID) systems, network attached storages (NAS) and storage area network (SAN). Moreover, we present a software solution, which we developed for the purpose of long-term preservation of large mass spectrometry raw data files on an object storage device (OSD) archiving system. Finally, advantages, disadvantages, and experiences from routine operations of the presented concepts and technologies are evaluated and discussed. This article is part of a Special Issue entitled: Computational Proteomics in the Post-Identification Era. Guest Editors: Martin Eisenacher and Christian Stephan. Copyright © 2013. Published by Elsevier B.V.

  4. Fuel Cells for Backup Power in Telecommunications Facilities (Fact Sheet)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    2009-04-01

    Telecommunications providers rely on backup power to maintain a constant power supply, to prevent power outages, and to ensure the operability of cell towers, equipment, and networks. The backup power supply that best meets these objectives is fuel cell technology.

  5. A SWOT Analysis of the Various Backup Scenarios Used in Electronic Medical Record Systems.

    PubMed

    Seo, Hwa Jeong; Kim, Hye Hyeon; Kim, Ju Han

    2011-09-01

    Electronic medical records (EMRs) are increasingly being used by health care services. Currently, if an EMR shutdown occurs, even for a moment, patient safety and care can be seriously impacted. Our goal was to determine the methodology needed to develop an effective and reliable EMR backup system. Our "independent backup system by medical organizations" paradigm implies that individual medical organizations develop their own EMR backup systems within their organizations. A "personal independent backup system" is defined as an individual privately managing his/her own medical records, whereas in a "central backup system by the government" the government controls all the data. A "central backup system by private enterprises" implies that individual companies retain control over their own data. A "cooperative backup system among medical organizations" refers to a networked system established through mutual agreement. The "backup system based on mutual trust between an individual and an organization" means that the medical information backup system at the organizational level is established through mutual trust. Through the use of SWOT analysis it can be shown that cooperative backup among medical organizations is possible to be established through a network composed of various medical agencies and that it can be managed systematically. An owner of medical information only grants data access to the specific person who gave the authorization for backup based on the mutual trust between an individual and an organization. By employing SWOT analysis, we concluded that a linkage among medical organizations or between an individual and an organization can provide an efficient backup system.

  6. A SWOT Analysis of the Various Backup Scenarios Used in Electronic Medical Record Systems

    PubMed Central

    Seo, Hwa Jeong; Kim, Hye Hyeon

    2011-01-01

    Objectives Electronic medical records (EMRs) are increasingly being used by health care services. Currently, if an EMR shutdown occurs, even for a moment, patient safety and care can be seriously impacted. Our goal was to determine the methodology needed to develop an effective and reliable EMR backup system. Methods Our "independent backup system by medical organizations" paradigm implies that individual medical organizations develop their own EMR backup systems within their organizations. A "personal independent backup system" is defined as an individual privately managing his/her own medical records, whereas in a "central backup system by the government" the government controls all the data. A "central backup system by private enterprises" implies that individual companies retain control over their own data. A "cooperative backup system among medical organizations" refers to a networked system established through mutual agreement. The "backup system based on mutual trust between an individual and an organization" means that the medical information backup system at the organizational level is established through mutual trust. Results Through the use of SWOT analysis it can be shown that cooperative backup among medical organizations is possible to be established through a network composed of various medical agencies and that it can be managed systematically. An owner of medical information only grants data access to the specific person who gave the authorization for backup based on the mutual trust between an individual and an organization. Conclusions By employing SWOT analysis, we concluded that a linkage among medical organizations or between an individual and an organization can provide an efficient backup system. PMID:22084811

  7. Expedition 14 Crew and Backup Crew Training

    NASA Image and Video Library

    2006-05-24

    JSC2006-E-20053 (24 May 2006) --- Astronaut Clayton C. Anderson, Expedition 14 backup flight engineer, participates in Journals experiment overview training in the Flight Operations Facility at Johnson Space Center. This type of training is a presentation format regarding the experiment objectives and tools. Training instructor Lindsay Kirschner assisted Anderson.

  8. Reducing Backups by Utilizing DMF

    NASA Technical Reports Server (NTRS)

    Cardo, Nicholas P.; Woodrow, Thomas (Technical Monitor)

    1994-01-01

    Although a filesystem may be migratable, for a period of time the data blocks are on disk only. When performing system dumps, these data blocks are backed up to tape. If the data blocks are offline or dual resident, then only the inode is backed up. If all online files are made dual resident prior to performing system dumps, the dump time and the amount of resources required can be significantly reduced. The High Speed Processors group at the Numerical Aerodynamics Simulation (NAS) Facility at NASA Ames Research Center developed a tool to make all online files dual resident. The result is that a file whose data blocks are on DMF tape and still assigned to the original inode. Our 150GB filesystem used to take 8 to 12 hours to backup and used 50 to 60 tapes. Now the backup is typically under 10 tapes and completes in under 2 hours. This paper discusses this new tool and advantages gained by using it.

  9. Close up of backup exciter showing induction motor at left ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Close up of backup exciter showing induction motor at left and direct current generator at right. View to west - Mystic Lake Hydroelectric Facility, Powerhouse, Along West Rosebud Creek, 1 3/4 miles northeast of Mystic Lake Dam, Fishtail, Stillwater County, MT

  10. Implementation of an ASP model offsite backup archive for clinical images utilizing Internet 2

    NASA Astrophysics Data System (ADS)

    Liu, Brent J.; Chao, Sander S.; Documet, Jorge; Lee, Jasper; Lee, Michael; Topic, Ian; Williams, Lanita

    2005-04-01

    With the development of PACS technology and an increasing demand by medical facilities to become filmless, there is a need for a fast and efficient method of providing data backup for disaster recovery and downtime scenarios. At the Image Processing Informatics Lab (IPI), an ASP Backup Archive was developed using a fault-tolerant server with a T1 connection to serve the PACS at the St. John's Health Center (SJHC) Santa Monica, California. The ASP archive server has been in clinical operation for more than 18 months, and its performance was presented at this SPIE Conference last year. This paper extends the ASP Backup Archive to serve the PACS at the USC Healthcare Consultation Center II (HCC2) utilizing an Internet2 connection. HCC2 is a new outpatient facility that recently opened in April 2004. The Internet2 connectivity between USC's HCC2 and IPI has been established for over one year. There are two novelties of the current ASP model: 1) Use of Internet2 for daily clinical operation, and 2) Modifying the existing backup archive to handle two sites in the ASP model. This paper presents the evaluation of the ASP Backup Archive based on the following two criteria: 1) Reliability and performance of the Internet2 connection between HCC2 and IPI using DICOM image transfer in a clinical environment, and 2) Ability of the ASP Fault-Tolerant backup archive to support two separate clinical PACS sites simultaneously. The performances of using T1 and Internet2 at the two different sites are also compared.

  11. Hydrogen Fuel Cell Performance as Telecommunications Backup Power in the United States

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kurtz, Jennifer; Saur, Genevieve; Sprik, Sam

    2015-03-01

    Working in collaboration with the U.S. Department of Energy (DOE) and industry project partners, the National Renewable Energy Laboratory (NREL) acts as the central data repository for the data collected from real-world operation of fuel cell backup power systems. With American Recovery and Reinvestment Act of 2009 (ARRA) co-funding awarded through DOE's Fuel Cell Technologies Office, more than 1,300 fuel cell units were deployed over a three-plus-year period in stationary, material handling equipment, auxiliary power, and backup power applications. This surpassed a Fuel Cell Technologies Office ARRA objective to spur commercialization of an early market technology by installing 1,000 fuelmore » cell units across several different applications, including backup power. By December 2013, 852 backup power units out of 1,330 fuel cell units deployed were providing backup service, mainly for telecommunications towers. For 136 of the fuel cell backup units, project participants provided detailed operational data to the National Fuel Cell Technology Evaluation Center for analysis by NREL's technology validation team. NREL analyzed operational data collected from these government co-funded demonstration projects to characterize key fuel cell backup power performance metrics, including reliability and operation trends, and to highlight the business case for using fuel cells in these early market applications. NREL's analyses include these critical metrics, along with deployment, U.S. grid outage statistics, and infrastructure operation.« less

  12. Rates for backup service under PURPA when the supplying utility has excess generating capacity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    Under PURPA, cogenerators are entitled to receive backup service. It is often said that tariffs for backup service should reflect the low probability that an unscheduled outage will occur during system peak. This memorandum concludes that probabilistic analysis of contribution to coincident peak demand is not relevant under PURPA during periods in which a utility system is experiencing generating capacity surpluses, and that in such situations, backup rates should be designed so that should the customer insist on installing a cogeneration system, that the customer's contribution to fixed costs remains constant. The reason for this is to assure that prospectivemore » cogenerators receive appropriate pricing signals in their assessment of proposed cogeneration projects, and should they decide to install cogeneration facilities requiring backup service, to hold the remaining customers on the system harmless.« less

  13. STS-47 crew & backups pose for portrait in SLJ module at KSC during training

    NASA Image and Video Library

    1992-07-25

    S92-44303 --- STS-47 Endeavour, Orbiter Vehicle (OV) 105, crew members and back-up payload specialists, wearing clean suits, pose for a group portrait in the Spacelab Japan (SLJ) module. The team is at the Kennedy Space Center's (KSC's) Orbiter Processing Facility (OPF) to inspect SLJ configuration and OV-105 preparations. Kneeling, from left, are back-up Payload Specialist Chiaki Naito-Mukai; Mission Specialist N. Jan Davis; and backup Payload Specialist Takao Doi. Standing, from the left, are Pilot Curtis L. Brown,Jr; Payload Commander Mark C. Lee; Jerome Apt; Payload Specialist Mamoru Mohri; Commander Robert L. Gibson; Mae C. Jemison; and back-up Payload Specialist Stanely L. Koszelak. Mohri, Mukai, and Doi represent the National Space Development Agency of Japan (NASDA). View provided by KSC with alternate KSC number KSC-92PC-1647. Photo credit: NASA

  14. Operating and Managing a Backup Control Center

    NASA Technical Reports Server (NTRS)

    Marsh, Angela L.; Pirani, Joseph L.; Bornas, Nicholas

    2010-01-01

    Due to the criticality of continuous mission operations, some control centers must plan for alternate locations in the event an emergency shuts down the primary control center. Johnson Space Center (JSC) in Houston, Texas is the Mission Control Center (MCC) for the International Space Station (ISS). Due to Houston s proximity to the Gulf of Mexico, JSC is prone to threats from hurricanes which could cause flooding, wind damage, and electrical outages to the buildings supporting the MCC. Marshall Space Flight Center (MSFC) has the capability to be the Backup Control Center for the ISS if the situation is needed. While the MSFC Huntsville Operations Support Center (HOSC) does house the BCC, the prime customer and operator of the ISS is still the JSC flight operations team. To satisfy the customer and maintain continuous mission operations, the BCC has critical infrastructure that hosts ISS ground systems and flight operations equipment that mirrors the prime mission control facility. However, a complete duplicate of Mission Control Center in another remote location is very expensive to recreate. The HOSC has infrastructure and services that MCC utilized for its backup control center to reduce the costs of a somewhat redundant service. While labor talents are equivalent, experiences are not. Certain operations are maintained in a redundant mode, while others are simply maintained as single string with adequate sparing levels of equipment. Personnel at the BCC facility must be trained and certified to an adequate level on primary MCC systems. Negotiations with the customer were done to match requirements with existing capabilities, and to prioritize resources for appropriate level of service. Because some of these systems are shared, an activation of the backup control center will cause a suspension of scheduled HOSC activities that may share resources needed by the BCC. For example, the MCC is monitoring a hurricane in the Gulf of Mexico. As the threat to MCC

  15. Fault-tolerant back-up archive using an ASP model for disaster recovery

    NASA Astrophysics Data System (ADS)

    Liu, Brent J.; Huang, H. K.; Cao, Fei; Documet, Luis; Sarti, Dennis A.

    2002-05-01

    A single point of failure in PACS during a disaster scenario is the main archive storage and server. When a major disaster occurs, it is possible to lose an entire hospital's PACS data. Few current PACS archives feature disaster recovery, but the design is limited at best. These drawbacks include the frequency with which the back-up is physically removed to an offsite facility, the operational costs associated to maintain the back-up, the ease-of-use to perform the backup consistently and efficiently, and the ease-of-use to perform the PACS image data recovery. This paper describes a novel approach towards a fault-tolerant solution for disaster recovery of short-term PACS image data using an Application Service Provider model for service. The ASP back-up archive provides instantaneous, automatic backup of acquired PACS image data and instantaneous recovery of stored PACS image data all at a low operational cost. A back-up archive server and RAID storage device is implemented offsite from the main PACS archive location. In the example of this particular hospital, it was determined that at least 2 months worth of PACS image exams were needed for back-up. Clinical data from a hospital PACS is sent to this ASP storage server in parallel to the exams being archived in the main server. A disaster scenario was simulated and the PACS exams were sent from the offsite ASP storage server back to the hospital PACS. Initially, connectivity between the main archive and the ASP storage server is established via a T-1 connection. In the future, other more cost-effective means of connectivity will be researched such as the Internet 2. A disaster scenario was initiated and the disaster recovery process using the ASP back-up archive server was success in repopulating the clinical PACS within a short period of time. The ASP back-up archive was able to recover two months of PACS image data for comparison studies with no complex operational procedures. Furthermore, no image data loss

  16. 47 CFR 12.2 - Backup power.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Backup power. 12.2 Section 12.2 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL REDUNDANCY OF COMMUNICATIONS SYSTEMS § 12.2 Backup power..., must have an emergency backup power source (e.g., batteries, generators, fuel cells) for all assets...

  17. First evidence for "The backup plan paradox".

    PubMed

    Napolitano, Christopher M; Freund, Alexandra M

    2017-08-01

    This research is a first test of the backup plan paradox. We hypothesized that investing in a backup plan may facilitate the conditions that it was developed to address: Plan A's insufficiency. Five studies provide initial, primarily correlative support for the undermining effect of investing in a backup plan. Study 1 (n= 160) demonstrated that the more participants perceived they had invested in developing a backup plan (preparing a "crib sheet"), the more likely they were to use it, although greater investments were unrelated to backup plan utility. Studies 2-4 used a simulated negotiation task. Study 2 (n = 247) demonstrated that when goal-relevant resources are limited, investing in developing backup plans and perceiving them as highly instrumental can decrease goal performance through the indirect effect of increased means replacing. Study 3 (n = 248) replicated this effect when goal-relevant resources were plentiful. Study 4 (n = 204) used an experimental variant of the simulated negotiation task and demonstrated that simply having a backup plan is not detrimental, but perceiving backup plans to be highly instrumental decreased goal performance, again through the indirect effect of increased means replacing. Study 5 (n = 160) replicated findings from Studies 1-4 using a lab-based motor task (throwing a ball). Together, these results provide first evidence that backup plans can introduce costs that may jeopardize goal performance. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  18. STS-47 Payload Specialist Mohri and Japanese backups pose in SLJ module at KSC

    NASA Technical Reports Server (NTRS)

    1992-01-01

    STS-47 payload specialists representing Japan's National Space Development Agency (NASDA) examine the interior of the Spacelab Japan (SLJ) laboratory module recently installed in Endeavour's, Orbiter Vehicle (OV) 105's, payload bay (PLB). Left to right are Payload Specialist Mamoru Mohri, backup Payload Specialist Chiaki Naito-Mukai, and backup Payload Specialist Takao Doi. The crewmembers visited OV-105, currently undergoing preflight processing in a high bay area of Kennedy Space Center's (KSC's) Orbiter Processing Facility (OPF). View provided by KSC with alternate KSC number KSC-92PC-1649.

  19. STS-55 backup Payload Specialist Thiele with technician in JSC's WETF

    NASA Technical Reports Server (NTRS)

    1992-01-01

    STS-55 Columbia, Orbiter Vehicle (OV) 102, backup German Payload Specialist Dr. P. Gerhard Thiele, wearing launch and entry suit (LES), launch and entry helmet (LEH), and parachute, seated on the poolside waits his turn to participate in launch emergency egress (bailout) exercises. The session, held in JSC's Weightless Environment Training Facility (WETF) Bldg 29, used the facility's 25-foot deep pool to simulate the ocean as Thiele and other crewmembers practiced water bailout procedures. Thiele represents the DLR for the upcoming Spacelab Deutsche 2 (SL-D2) mission.

  20. STS-47 backup payload specialists participate in JSC WETF bailout exercise

    NASA Technical Reports Server (NTRS)

    1992-01-01

    STS-47 Endeavour, Orbiter Vehicle (OV) 105, backup payload specialists (left to right) Chiaki Naito-Mukai, Takao Doi, and Stan Koszelak, wearing launch and entry suits, sit on the poolside in JSC's Weightless Environment Training Facility (WETF) Bldg 29. These alternates are waiting to participate launch emergency egress (bailout) exercises. The training is conducted in the WETF pool to simulate a water landing.

  1. STS-52 backup Payload Specialist Tryggvason during JSC bailout exercises

    NASA Technical Reports Server (NTRS)

    1992-01-01

    STS-52 Columbia, Orbiter Vehicle (OV) 102, backup Payload Specialist Bjarni V. Tryggvason, wearing launch and entry suit (LES), checks his launch and entry helmet (LEH) fitting prior to participating in emergency egress (bailout) training exercises in JSC's Weightless Environment Training Facility (WETF) Bldg 29. The WETF's 25-ft deep pool will serve as the ocean during this water landing simulation. Tryggvason represents the Canadian Space Agency (CSA).

  2. STS-55 German payload specialists and backups pose in front of SL-D2 at KSC

    NASA Technical Reports Server (NTRS)

    1992-01-01

    STS-55 Columbia, Orbiter Vehicle (OV) 102, German payload specialists and backup (alternate) payload specialists pose in front of the Spacelab Deutsche 2 (SL-D2) science module at a Kennedy Space Center (KSC) processing facility. These four Germans have been assigned to support the STS-55/SL-D2 mission. Left to right are Payload Specialist 2 Hans Schlegel, backup Payload Specialist Dr. P. Gerhard Thiele (kneeling), Payload Specialist 1 Ulrich Walter, and backup Payload Specialist Renate Brummer. Walter and Schlegel are scheduled to fly aboard OV-102 for the mission while Brummer and Thiele will serve as alternates and fill supportive roles on the ground. Clearly visible on the SL-D2 module are the European Space Agency (ESA) insignia, the feedthrough plate, and the D2 insignia.

  3. 12 CFR 741.210 - Central liquidity facility.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 12 Banks and Banking 6 2010-01-01 2010-01-01 false Central liquidity facility. 741.210 Section 741... Unions That Also Apply to Federally Insured State-Chartered Credit Unions § 741.210 Central liquidity... Liquidity Facility, shall adhere to the requirements stated in part 725 of this chapter. ...

  4. Operational summary of an electric propulsion long term test facility

    NASA Technical Reports Server (NTRS)

    Trump, G. E.; James, E. L.; Bechtel, R. T.

    1982-01-01

    An automated test facility capable of simultaneously operating three 2.5 kW, 30-cm mercury ion thrusters and their power processors is described, along with a test program conducted for the documentation of thruster characteristics as a function of time. Facility controls are analog, with full redundancy, so that in the event of malfunction the facility automaticcally activates a backup mode and notifies an operator. Test data are recorded by a central data collection system and processed as daily averages. The facility has operated continuously for a period of 37 months, over which nine mercury ion thrusters and four power processor units accumulated a total of over 14,500 hours of thruster operating time.

  5. STS-45 backup Payload Specialist Chappell during water egress training at JSC

    NASA Technical Reports Server (NTRS)

    1991-01-01

    STS-45 Atlantis, Orbiter Vehicle (OV) 104, backup Payload Specialist Charles R. Chappell, wearing launch and entry suit (LES), is suspended via his parachute harness above JSC's Weightless Environment Training Facility (WETF) Bldg 29 pool. Chappell will be dropped into the pool during the exercise which simulates a parachute landing into a body of water. SCUBA-equipped divers swimming in the pool will assist during the training.

  6. Backup agreements with penalty scheme under supply disruptions

    NASA Astrophysics Data System (ADS)

    Hou, Jing; Zhao, Lindu

    2012-05-01

    This article considers a supply chain for a single product involving one retailer and two independent suppliers, when the main supplier might fail to supply the products, the backup supplier can always supply the products at a higher price. The retailer could use the backup supplier as a regular provider or a stand-by source by reserving some products at the supplier. A backup agreement with penalty scheme is constructed between the retailer and the backup supplier to mitigate the supply disruptions and the demand uncertainty. The expected profit functions and the optimal decisions of the two players are derived through a sequential optimisation process. Then, the sensitivity of two players' expected profits to various input factors is examined through numerical examples. The impacts of the disruption probability and the demand uncertainty on the backup agreement are also investigated, which could provide guideline for how to use each sourcing method.

  7. Applying secret sharing for HIS backup exchange.

    PubMed

    Kuroda, Tomohiro; Kimura, Eizen; Matsumura, Yasushi; Yamashita, Yoshinori; Hiramatsu, Haruhiko; Kume, Naoto; Sato, Atsushi

    2013-01-01

    To secure business continuity is indispensable for hospitals to fulfill its social responsibility under disasters. Although to back up the data of the hospital information system (HIS) at multiple remote sites is a key strategy of business continuity plan (BCP), the requirements to treat privacy sensitive data jack up the cost for the backup. The secret sharing is a method to split an original secret message up so that each individual piece is meaningless, but putting sufficient number of pieces together to reveal the original message. The secret sharing method eases us to exchange HIS backups between multiple hospitals. This paper evaluated the feasibility of the commercial secret sharing solution for HIS backup through several simulations. The result shows that the commercial solution is feasible to realize reasonable HIS backup exchange platform when template of contract between participating hospitals is ready.

  8. Gemini 8 prime and backup crews during press conference

    NASA Image and Video Library

    1966-02-26

    S66-24380 (26 Feb. 1966) --- Gemini-8 prime and backup crews during press conference. Left to right are astronauts David R. Scott, prime crew pilot; Neil A. Armstrong, prime crew command pilot; Charles Conrad Jr., backup crew command pilot; and Richard F. Gordon Jr., backup crew pilot. Photo credit: NASA

  9. Outcomes of nonemergent percutaneous coronary intervention with and without on-site surgical backup: a meta-analysis.

    PubMed

    Singh, Param Puneet; Singh, Mukesh; Bedi, Updesh Singh; Adigopula, Sasikanth; Singh, Sarabjeet; Kodumuri, Vamsi; Molnar, Janos; Ahmed, Aziz; Arora, Rohit; Khosla, Sandeep

    2011-01-01

    Despite major advances in percutaneous coronary intervention (PCI) techniques, the current guidelines recommend against elective PCI at hospitals without on-site cardiac surgery backup. Nonetheless, an increasing number of hospitals without on-site cardiac surgery in the United States have developed programs for elective PCI. Studies evaluating outcome in this setting have yielded mixed results, leaving the question unanswered. Hence, a meta-analysis comparing outcomes of nonemergent PCI in hospitals with and without on-site surgical backup was performed. A systematic review of literature identified four studies involving 6817 patients. Three clinical end points were extracted from each study and included in-hospital death, myocardial infarction, and the need for emergency coronary artery bypass grafting. The studies were homogenous for each outcome studied. Therefore, the combined relative risks (RRs) across all the studies and the 95% confidence intervals (CIs) were computed using the Mantel-Haenszel fixed-effect model. A two-sided alpha error less than 0.05 was considered to be statistically significant. Compared with facilities with on-site surgical backup, the risk of in-hospital death (RR, 2.7; CI, 0.6-12.9; P = 0.18), nonfatal myocardial infarction (RR, 1.3; CI, 0.7- 2.2; P = 0.29), and need of emergent coronary artery bypass grafting (RR, 0.46; CI, 0.06- 3.1; P = 0.43) was similar in those lacking on-site surgical backup. The present meta-analysis suggests that there is no difference in the outcome with regard to risk of nonfatal myocardial infarction, need for emergency coronary artery bypass grafting, and the risk of death in patients undergoing elective PCI in hospitals with and without on-site cardiac surgery backup.

  10. Central Computational Facility CCF communications subsystem options

    NASA Technical Reports Server (NTRS)

    Hennigan, K. B.

    1979-01-01

    A MITRE study which investigated the communication options available to support both the remaining Central Computational Facility (CCF) computer systems and the proposed U1108 replacements is presented. The facilities utilized to link the remote user terminals with the CCF were analyzed and guidelines to provide more efficient communications were established.

  11. Accelerating Acceptance of Fuel Cell Backup Power Systems - Final Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Petrecky, James; Ashley, Christopher

    2014-07-21

    Since 2001, Plug Power has installed more than 800 stationary fuel cell systems worldwide. Plug Power’s prime power systems have produced approximately 6.5 million kilowatt hours of electricity and have accumulated more than 2.5 million operating hours. Intermittent, or backup, power products have been deployed with telecommunications carriers and government and utility customers in North and South America, Europe, the United Kingdom, Japan and South Africa. Some of the largest material handling operations in North America are currently using the company’s motive power units in fuel cell-powered forklifts for their warehouses, distribution centers and manufacturing facilities. The low-temperature GenSys fuelmore » cell system provides remote, off-grid and primary power where grid power is unreliable or nonexistent. Built reliable and designed rugged, low- temperature GenSys delivers continuous or backup power through even the most extreme conditions. Coupled with high-efficiency ratings, low-temperature GenSys reduces operating costs making it an economical solution for prime power requirements. Currently, field trials at telecommunication and industrial sites across the globe are proving the advantages of fuel cells—lower maintenance, fuel costs and emissions, as well as longer life—compared with traditional internal combustion engines.« less

  12. Central-Approach Surgical Repair of Coarctation of the Aorta with a Back-up Left Ventricular Assist Device for an Infant Presenting with Severe Left Ventricular Dysfunction.

    PubMed

    Kim, Tae Hoon; Shin, Yu Rim; Kim, Young Sam; Kim, Do Jung; Kim, Hyohyun; Shin, Hong Ju; Htut, Aung Thein; Park, Han Ki

    2015-12-01

    A two-month-old infant presented with coarctation of the aorta, severe left ventricular dysfunction, and moderate to severe mitral regurgitation. Through median sternotomy, the aortic arch was repaired under cardiopulmonary bypass and regional cerebral perfusion. The patient was postoperatively supported with a left ventricular assist device for five days. Left ventricular function gradually improved, eventually recovering with the concomitant regression of mitral regurgitation. Prompt surgical repair of coarctation of the aorta is indicated for patients with severe left ventricular dysfunction. A central approach for surgical repair with a back-up left ventricular assist device is a safe and effective treatment strategy for these patients.

  13. 30 CFR 75.1101-9 - Back-up water system.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Back-up water system. 75.1101-9 Section 75.1101-9 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1101-9 Back-up water system...

  14. 30 CFR 75.1101-9 - Back-up water system.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Back-up water system. 75.1101-9 Section 75.1101-9 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1101-9 Back-up water system...

  15. 30 CFR 75.1101-9 - Back-up water system.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Back-up water system. 75.1101-9 Section 75.1101-9 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1101-9 Back-up water system...

  16. 30 CFR 75.1101-9 - Back-up water system.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Back-up water system. 75.1101-9 Section 75.1101-9 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1101-9 Back-up water system...

  17. 30 CFR 75.1101-9 - Back-up water system.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Back-up water system. 75.1101-9 Section 75.1101-9 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1101-9 Back-up water system...

  18. STS-47 crew and backups at MSFC's Payload Crew Training Complex

    NASA Technical Reports Server (NTRS)

    1992-01-01

    STS-47 Endeavour, Orbiter Vehicle (OV) 105, Spacelab Japan (SLJ) crewmembers and backup payload specialists stand outside SLJ module mockup at the Payload Crew Training Complex at Marshall SpaceFlight Center (MSFC) in Huntsville, Alabama. From left to right are Payload Specialist Mamoru Mohri, backup Payload Specialist Takao Doi, backup Payload Specialist Chiaki Naito-Mukai, Mission Specialist (MS) Mae C. Jemison, MS N. Jan Davis, backup Payload Specialist Stan Koszelak, and MS and Payload Commander (PLC) Mark C. Lee. The MSFC-managed mission is a joint venture in space-based research between the United States and Japan. Mohri, Doi, and Mukai represent Japan's National Space Development Agency (NASDA). View provided with alternate number 92P-142.

  19. Enhanced networked server management with random remote backups

    NASA Astrophysics Data System (ADS)

    Kim, Song-Kyoo

    2003-08-01

    In this paper, the model is focused on available server management in network environments. The (remote) backup servers are hooked up by VPN (Virtual Private Network) and replace broken main severs immediately. A virtual private network (VPN) is a way to use a public network infrastructure and hooks up long-distance servers within a single network infrastructure. The servers can be represent as "machines" and then the system deals with main unreliable and random auxiliary spare (remote backup) machines. When the system performs a mandatory routine maintenance, auxiliary machines are being used for backups during idle periods. Unlike other existing models, the availability of auxiliary machines is changed for each activation in this enhanced model. Analytically tractable results are obtained by using several mathematical techniques and the results are demonstrated in the framework of optimized networked server allocation problems.

  20. Reliable Facility Location Problem with Facility Protection

    PubMed Central

    Tang, Luohao; Zhu, Cheng; Lin, Zaili; Shi, Jianmai; Zhang, Weiming

    2016-01-01

    This paper studies a reliable facility location problem with facility protection that aims to hedge against random facility disruptions by both strategically protecting some facilities and using backup facilities for the demands. An Integer Programming model is proposed for this problem, in which the failure probabilities of facilities are site-specific. A solution approach combining Lagrangian Relaxation and local search is proposed and is demonstrated to be both effective and efficient based on computational experiments on random numerical examples with 49, 88, 150 and 263 nodes in the network. A real case study for a 100-city network in Hunan province, China, is presented, based on which the properties of the model are discussed and some managerial insights are analyzed. PMID:27583542

  1. STS-9 payload specialists and backup in training session

    NASA Technical Reports Server (NTRS)

    1983-01-01

    Two Spacelab 1 payload specialists and a backup for that flight prepare for a training session in the JSC mockup and integration laboratory. Fully decked out in the Shuttle constant wear garments (foreground) are Ulf Merbold, left, and Byron K. Licktenberg, prime crewmembers on the STS-9 team. In civilian clothes is payload specialist backup Michael L. Lampton.

  2. Clinical experiences with an ASP model backup archive for PACS images

    NASA Astrophysics Data System (ADS)

    Liu, Brent J.; Cao, Fei; Documet, Luis; Huang, H. K.; Muldoon, Jean

    2003-05-01

    Last year we presented a Fault-Tolerant Backup Archive using an Application Service Provider (ASP) model for disaster recovery. The purpose of this paper is to update and provide clinical experiences related towards implementing the ASP model archive solution for short-term backup of clinical PACS image data as well as possible applications other than disaster recovery. The ASP backup archive provides instantaneous, automatic backup of acquired PACS image data and instantaneous recovery of stored PACS image data all at a low operational cost and with little human intervention. This solution can be used for a variety of scheduled and unscheduled downtimes that occur on the main PACS archive. A backup archive server with hierarchical storage was implemented offsite from the main PACS archive location. Clinical data from a hospital PACS is sent to this ASP storage server in parallel to the exams being archived in the main server. Initially, connectivity between the main archive and the ASP storage server is established via a T-1 connection. In the future, other more cost-effective means of connectivity will be researched such as the Internet 2. We have integrated the ASP model backup archive with a clinical PACS at Saint John's Health Center and has been operational for over 6 months. Pitfalls encountered during integration with a live clinical PACS and the impact to clinical workflow will be discussed. In addition, estimations of the cost of establishing such a solution as well as the cost charged to the users will be included. Clinical downtime scenarios, such as a scheduled mandatory downtime and an unscheduled downtime due to a disaster event to the main archive, were simulated and the PACS exams were sent successfully from the offsite ASP storage server back to the hospital PACS in less than 1 day. The ASP backup archive was able to recover PACS image data for comparison studies with no complex operational procedures. Furthermore, no image data loss was

  3. Researching, Evaluating, and Choosing a Backup Service in the Cloud

    ERIC Educational Resources Information Center

    Hastings, Robin

    2012-01-01

    Backups are a modern fact of life. Every organization that has any kind of computing technology (and that is all of them these days) needs to back up its data in case of technological or user errors. Traditionally, large-scale backups have been done via an internal or external tape drive that takes magnetic tapes (minicassettes, essentially) and…

  4. Gemini 7 backup crew seen in white room during Gemini 7 simulation activity

    NASA Image and Video Library

    1965-11-27

    S65-61837 (27 Nov. 1965) --- The Gemini-7 backup crew seen in the White Room atop Pad 19 during Gemini-7 simulation flight activity. McDonnell Aircraft Corporation technicians assist in the exercise. Astronaut Edward H. White II (in foreground) is the Gemini-7 backup crew command pilot; and astronaut Michael Collins (right background) is the backup crew pilot. Photo credit: NASA

  5. Central Facilities Area Sewage Lagoon Evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Giesbrecht, Alan

    2015-03-01

    The Central Facilities Area (CFA) located in Butte County, Idaho at Idaho National Laboratory (INL) has an existing wastewater system to collect and treat sanitary wastewater and non contact cooling water from the facility. The existing treatment facility consists of three cells: Cell 1 has a surface area of 1.7 acres, Cell 2 has a surface area of 10.3 acres, and Cell 3 has a surface area of 0.5 acres. If flows exceed the evaporative capacity of the cells, wastewater is discharged to a 73.5 acre land application site that utilizes a center pivot irrigation sprinkler system. The purpose ofmore » this current study is to update the analysis and conclusions of the December 2013 study. In this current study, the new seepage rate and influent flow rate data have been used to update the calculations, model, and analysis.« less

  6. Apollo 16 prime and backup crewmen during geological field trip in New Mexico

    NASA Image and Video Library

    1971-09-09

    Dr. Lee Silver (pointing foregroung), California Institute of Technology, calls a geological feature near Taos, New Mexico, to the attention of Apollo 16 prime and backup crewmen during a geological field trip. The crewmen, from left to right, are Astronauts Charles M. Duke Jr., lunar module pilot; Fred W. Haise Jr., backup commander; Edgar D. Mitchell, backup Lunar Module pilot; and John W. Young, commander.

  7. Apollo 11 - Prime and Backup Crews - Geology Training - TX

    NASA Image and Video Library

    1969-03-03

    S69-25199 (25 Feb. 1969) --- Two Apollo 11 astronauts study a rock specimen during a geological field trip to the Quitman Mountains area near the Fort Quitman ruins in far west Texas. On the left is James A. Lovell Jr., Apollo 11 backup crew commander; and on the right is Fred W. Haise Jr., backup crew lunar module pilot. Lovell holds a camera which was used in simulating taking pictures of actual lunar samples on the surface of the Moon.

  8. Independent backup mode transfer and mechanism for digital control computers

    NASA Technical Reports Server (NTRS)

    Tulpule, Bhalchandra R. (Inventor); Oscarson, Edward M. (Inventor)

    1992-01-01

    An interrupt is provided to a signal processor having a non-maskable interrupt input, in response to the detection of a request for transfer to backup software. The signal processor provides a transfer signal to a transfer mechanism only after completion of the present machine cycle. Transfer to the backup software is initiated by the transfer mechanism only upon reception of the transfer signal.

  9. 47 CFR 12.2 - Backup power.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... exchange carriers, including incumbent local exchange carriers and competitive local exchange carriers..., must have an emergency backup power source (e.g., batteries, generators, fuel cells) for all assets... or local law; (2) Risk to safety of life or health; or (3) Private legal obligation or agreement. (c...

  10. The depth of the honeybee's backup sun-compass systems.

    PubMed

    Dovey, Katelyn M; Kemfort, Jordan R; Towne, William F

    2013-06-01

    Honeybees have at least three compass mechanisms: a magnetic compass; a celestial or sun compass, based on the daily rotation of the sun and sun-linked skylight patterns; and a backup celestial compass based on a memory of the sun's movements over time in relation to the landscape. The interactions of these compass systems have yet to be fully elucidated, but the celestial compass is primary in most contexts, the magnetic compass is a backup in certain contexts, and the bees' memory of the sun's course in relation to the landscape is a backup system for cloudy days. Here we ask whether bees have any further compass systems, for example a memory of the sun's movements over time in relation to the magnetic field. To test this, we challenged bees to locate the sun when their known celestial compass systems were unavailable, that is, under overcast skies in unfamiliar landscapes. We measured the bees' knowledge of the sun's location by observing their waggle dances, by which foragers indicate the directions toward food sources in relation to the sun's compass bearing. We found that bees have no celestial compass systems beyond those already known: under overcast skies in unfamiliar landscapes, bees attempt to use their landscape-based backup system to locate the sun, matching the landscapes or skylines at the test sites with those at their natal sites as best they can, even if the matches are poor and yield weak or inconsistent orientation.

  11. Improving the Quality of Backup Process for Publishing Houses and Printing Houses

    NASA Astrophysics Data System (ADS)

    Proskuriakov, N. E.; Yakovlev, B. S.; Pries, V. V.

    2018-04-01

    The analysis of main types for data threats, used by print media, and their influence on the vitality and security of information is made. The influence of the programs settings for preparing archive files, the types of file managers on the backup process is analysed. We proposed a simple and economical version of the practical implementation of the backup process consisting of 4 components: the command line interpreter, the 7z archiver, the Robocopy utility, and network storage. We recommend that the best option would be to create backup copies, consisting of three local copies of data and two network copies.

  12. [Positional accuracy and quality assurance of Backup JAWs required for volumetric modulated arc therapy].

    PubMed

    Tatsumi, Daisaku; Nakada, Ryosei; Ienaga, Akinori; Yomoda, Akane; Inoue, Makoto; Ichida, Takao; Hosono, Masako

    2012-01-01

    The tolerance of the Backup diaphragm (Backup JAW) setting in Elekta linac was specified as 2 mm according to the AAPM TG-142 report. However, the tolerance and the quality assurance procedure for volumetric modulated arc therapy (VMAT) was not provided. This paper describes positional accuracy and quality assurance procedure of the Backup JAWs required for VMAT. It was found that a gap-width error of the Backup JAW by a sliding window test needed to be less than 1.5 mm for prostate VMAT delivery. It was also confirmed that the gap-widths had been maintained with an error of 0.2 mm during the past one year.

  13. A hybrid data compression approach for online backup service

    NASA Astrophysics Data System (ADS)

    Wang, Hua; Zhou, Ke; Qin, MingKang

    2009-08-01

    With the popularity of Saas (Software as a service), backup service has becoming a hot topic of storage application. Due to the numerous backup users, how to reduce the massive data load is a key problem for system designer. Data compression provides a good solution. Traditional data compression application used to adopt a single method, which has limitations in some respects. For example data stream compression can only realize intra-file compression, de-duplication is used to eliminate inter-file redundant data, compression efficiency cannot meet the need of backup service software. This paper proposes a novel hybrid compression approach, which includes two levels: global compression and block compression. The former can eliminate redundant inter-file copies across different users, the latter adopts data stream compression technology to realize intra-file de-duplication. Several compressing algorithms were adopted to measure the compression ratio and CPU time. Adaptability using different algorithm in certain situation is also analyzed. The performance analysis shows that great improvement is made through the hybrid compression policy.

  14. Backup Warning Signals: Driver Perception and Response

    DOT National Transportation Integrated Search

    1996-08-01

    This report describes the findings of three experiments that concern driver reaction to acoustic signals that might be used for backup warning devices. Intelligent warning devices are under development that will use vehicle-based sensors to warn back...

  15. Sprawling nursery unveils propane backup for natural gas boilers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1991-02-01

    First, take the most authoritative policy- making body in the pervasive problem area of Southern California air pollution (South Coast Air Quality Management District - SCAQMD). Then apply that organization's recently- enacted regulation prohibiting the use of diesel fuel in boilers to a well-known commercial establishment. The result is an alternative fuel story, that's too engaging to overlook. Monrovia Nursery, a 65-year-old, 500-acre wholesale growing facility in Azusa, Calif., has installed two 200-hp Dixon boilers, a 14 MMBtuh Sam Dick Industries vaporizer, and six 1150-gal. tanks on the property for the use of propane as a backup fuel. While themore » nursery ordinarily uses natural gas for water heating, there are times during the winter when the supply may be curtailed or interrupted. It is then that propane would be used to heat water to keep more than 1200 varieties of plants growing as they should.« less

  16. Mechanization of and experience with a triplex fly-by-wire backup control system

    NASA Technical Reports Server (NTRS)

    Lock, W. P.; Petersen, W. R.; Whitman, G. B.

    1976-01-01

    A redundant three axis analog control system was designed and developed to back up a digital fly by wire control system for an F-8C airplane. The mechanization and operational experience with the backup control system, the problems involved in synchronizing it with the primary system, and the reliability of the system are discussed. The backup control system was dissimilar to the primary system, and it provided satisfactory handling through the flight envelope evaluated. Limited flight tests of a variety of control tasks showed that control was also satisfactory when the backup control system was controlled by a minimum displacement (force) side stick. The operational reliability of the F-8 digital fly by wire control system was satisfactory, with no unintentional downmodes to the backup control system in flight. The ground and flight reliability of the system's components is discussed.

  17. CENTRAL FOOD STORE FACILITIES FOR COLLEGES AND UNIVERSITIES.

    ERIC Educational Resources Information Center

    BLOOMFIELD, BYRON C.

    INSPECTION OF A NUMBER OF INSTALLATIONS WAS ORIENTED TOWARD ARCHITECTURAL AND PLANNING QUESTIONS INVOLVING ECONOMICS AND SERVICES OF CENTRAL FOOD STORE FACILITIES. COMMENCING WITH THE PURCHASING PHILOSOPHY WHICH OVERVIEWS THE ORGANIZATION OF FOODS PURCHASING, SELECTION OF PERSONNEL, SPECIFICATIONS FOR PURCHASING, TECHNIQUES FOR PURCHASING, AND…

  18. 26 CFR 48.4082-4 - Diesel fuel and kerosene; back-up tax.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 26 Internal Revenue 16 2011-04-01 2011-04-01 false Diesel fuel and kerosene; back-up tax. 48.4082..., and Taxable Fuel Taxable Fuel § 48.4082-4 Diesel fuel and kerosene; back-up tax. (a) Imposition of tax... fuel or kerosene on which tax has not been imposed by section 4081; (ii) Any diesel fuel or kerosene...

  19. 26 CFR 48.4082-4 - Diesel fuel and kerosene; back-up tax.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 26 Internal Revenue 16 2012-04-01 2012-04-01 false Diesel fuel and kerosene; back-up tax. 48.4082..., and Taxable Fuel Taxable Fuel § 48.4082-4 Diesel fuel and kerosene; back-up tax. (a) Imposition of tax... fuel or kerosene on which tax has not been imposed by section 4081; (ii) Any diesel fuel or kerosene...

  20. 26 CFR 48.4082-4 - Diesel fuel and kerosene; back-up tax.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 26 Internal Revenue 16 2013-04-01 2013-04-01 false Diesel fuel and kerosene; back-up tax. 48.4082..., and Taxable Fuel Taxable Fuel § 48.4082-4 Diesel fuel and kerosene; back-up tax. (a) Imposition of tax... fuel or kerosene on which tax has not been imposed by section 4081; (ii) Any diesel fuel or kerosene...

  1. PLANNING THE OUTDOOR PHYSICAL EDUCATION FACILITIES FOR CENTRAL SCHOOLS. PLANNING THE OUTDOOR PHYSICAL EDUCATION FACILITIES, NO. 10.

    ERIC Educational Resources Information Center

    New York State Education Dept., Albany.

    PLANNING OUTDOOR PHYSICAL EDUCATION FACILITIES FOR THE CENTRAL SCHOOL SERVING PUPILS FROM KINDERGARTEN THROUGH HIGH SCHOOL SHOULD TAKE INTO ACCOUNT THE NEEDS AND INTERESTS OF ALL PUPILS DURING THE SCHOOL YEAR AND SHOULD PROVIDE FOR RECREATION NEEDS DURING VACATION PERIODS. PROVISION FOR RECREATIONAL FACILITIES FOR ADULTS SHOULD ALSO BE MADE. THE…

  2. Mechanization of and experience with a triplex fly-by-wire backup control system

    NASA Technical Reports Server (NTRS)

    Lock, W. P.; Petersen, W. R.; Whitman, G. B.

    1975-01-01

    A redundant three-axis analog control system was designed and developed to back up a digital fly-by-wire control system for an F-8C airplane. Forty-two flights, involving 58 hours of flight time, were flown by six pilots. The mechanization and operational experience with the backup control system, the problems involved in synchronizing it with the primary system, and the reliability of the system are discussed. The backup control system was dissimilar to the primary system, and it provided satisfactory handling through the flight envelope evaluated. Limited flight tests of a variety of control tasks showed that control was also satisfactory when the backup control system was controlled by a minimum-displacement (force) side stick. The operational reliability of the F-8 digital fly-by-wire control system was satisfactory, with no unintentional downmodes to the backup control system in flight. The ground and flight reliability of the system's components is discussed.

  3. Fuel Cell Backup Power System for Grid Service and Micro-Grid in Telecommunication Applications: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ma, Zhiwen; Eichman, Joshua D; Kurtz, Jennifer M

    This paper presents the feasibility and economics of using fuel cell backup power systems in telecommunication cell towers to provide grid services (e.g., ancillary services, demand response). The fuel cells are able to provide power for the cell tower during emergency conditions. This study evaluates the strategic integration of clean, efficient, and reliable fuel cell systems with the grid for improved economic benefits. The backup systems have potential as enhanced capability through information exchanges with the power grid to add value as grid services that depend on location and time. The economic analysis has been focused on the potential revenuemore » for distributed telecommunications fuel cell backup units to provide value-added power supply. This paper shows case studies on current fuel cell backup power locations and regional grid service programs. The grid service benefits and system configurations for different operation modes provide opportunities for expanding backup fuel cell applications responsive to grid needs.« less

  4. Backup Attitude Control Algorithms for the MAP Spacecraft

    NASA Technical Reports Server (NTRS)

    ODonnell, James R., Jr.; Andrews, Stephen F.; Ericsson-Jackson, Aprille J.; Flatley, Thomas W.; Ward, David K.; Bay, P. Michael

    1999-01-01

    The Microwave Anisotropy Probe (MAP) is a follow-on to the Differential Microwave Radiometer (DMR) instrument on the Cosmic Background Explorer (COBE) spacecraft. The MAP spacecraft will perform its mission, studying the early origins of the universe, in a Lissajous orbit around the Earth-Sun L(sub 2) Lagrange point. Due to limited mass, power, and financial resources, a traditional reliability concept involving fully redundant components was not feasible. This paper will discuss the redundancy philosophy used on MAP, describe the hardware redundancy selected (and why), and present backup modes and algorithms that were designed in lieu of additional attitude control hardware redundancy to improve the odds of mission success. Three of these modes have been implemented in the spacecraft flight software. The first onboard mode allows the MAP Kalman filter to be used with digital sun sensor (DSS) derived rates, in case of the failure of one of MAP's two two-axis inertial reference units. Similarly, the second onboard mode allows a star tracker only mode, using attitude and derived rate from one or both of MAP's star trackers for onboard attitude determination and control. The last backup mode onboard allows a sun-line angle offset to be commanded that will allow solar radiation pressure to be used for momentum management and orbit stationkeeping. In addition to the backup modes implemented on the spacecraft, two backup algorithms have been developed in the event of less likely contingencies. One of these is an algorithm for implementing an alternative scan pattern to MAP's nominal dual-spin science mode using only one or two reaction wheels and thrusters. Finally, an algorithm has been developed that uses thruster one shots while in science mode for momentum management. This algorithm has been developed in case system momentum builds up faster than anticipated, to allow adequate momentum management while minimizing interruptions to science. In this paper, each mode and

  5. 26 CFR 48.4082-4 - Diesel fuel and kerosene; back-up tax.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 26 Internal Revenue 16 2010-04-01 2010-04-01 true Diesel fuel and kerosene; back-up tax. 48.4082-4..., and Taxable Fuel Taxable Fuel § 48.4082-4 Diesel fuel and kerosene; back-up tax. (a) Imposition of tax... fuel or kerosene on which tax has not been imposed by section 4081; (ii) Any diesel fuel or kerosene...

  6. How to maintain blood supply during computer network breakdown: a manual backup system.

    PubMed

    Zeiler, T; Slonka, J; Bürgi, H R; Kretschmer, V

    2000-12-01

    Electronic data management systems using computer network systems and client/server architecture are increasingly used in laboratories and transfusion services. Severe problems arise if there is no network access to the database server and critical functions are not available. We describe a manual backup system (MBS) developed to maintain the delivery of blood products to patients in a hospital transfusion service in case of a computer network breakdown. All data are kept on a central SQL database connected to peripheral workstations in a local area network (LAN). Request entry from wards is performed via machine-readable request forms containing self-adhesive specimen labels with barcodes for test tubes. Data entry occurs on-line by bidirectional automated systems or off-line manually. One of the workstations in the laboratory contains a second SQL database which is frequently and incrementally updated. This workstation is run as a stand-alone, read-only database if the central SQL database is not available. In case of a network breakdown, the time-graded MBS is launched. Patient data, requesting ward and ordered tests/requests, are photocopied through a template from the request forms on special MBS worksheets serving as laboratory journal for manual processing and result report (a copy is left in the laboratory). As soon as the network is running again the data from the off-line period are entered into the primary SQL server. The MBS was successfully used at several occasions. The documentation of a 90-min breakdown period is presented in detail. Additional work resulted from the copy work and the belated manual data entry after restoration of the system. There was no delay in issue of blood products or result reporting. The backup system described has been proven to be simple, quick and safe to maintain urgent blood supply and distribution of laboratory results in case of unexpected network breakdown.

  7. Reliability considerations of a fuel cell backup power system for telecom applications

    NASA Astrophysics Data System (ADS)

    Serincan, Mustafa Fazil

    2016-03-01

    A commercial fuel cell backup power unit is tested in real life operating conditions at a base station of a Turkish telecom operator. The fuel cell system responds to 256 of 260 electric power outages successfully, providing the required power to the base station. Reliability of the fuel cell backup power unit is found to be 98.5% at the system level. On the other hand, a qualitative reliability analysis at the component level is carried out. Implications of the power management algorithm on reliability is discussed. Moreover, integration of the backup power unit to the base station ecosystem is reviewed in the context of reliability. Impact of inverter design on the stability of the output power is outlined. Significant current harmonics are encountered when a generic inverter is used. However, ripples are attenuated significantly when a custom design inverter is used. Further, fault conditions are considered for real world case studies such as running out of hydrogen, a malfunction in the system, or an unprecedented operating scheme. Some design guidelines are suggested for hybridization of the backup power unit for an uninterrupted operation.

  8. The near-source impacts of diesel backup generators in urban environments

    NASA Astrophysics Data System (ADS)

    Tong, Zheming; Zhang, K. Max

    2015-05-01

    Distributed power generation, located close to consumers, plays an important role in the current and future power systems. However, its near-source impacts in complex urban environments are not well understood. In this paper, we focused on diesel backup generators that participate in demand response (DR) programs. We first improved the micro-environmental air quality simulations by employing a meteorology processor, AERMET, to generate site-specific boundary layer parameters for the Large Eddy Simulation (LES) modeling. The modeling structure was then incorporated into the CTAG model to evaluate the environmental impacts of diesel backup generators in near-source microenvironments. We found that the presence of either tall upwind or downwind building can deteriorate the air quality in the near-stack street canyons, largely due to the recirculation zones generated by the tall buildings, reducing the near-stack dispersion. Decreasing exhaust momentum ratio (stack exit velocity/ambient wind velocity) draws more exhaust into the recirculation zone, and reduces the effective stack height, which results in elevated near-ground concentrations inside downwind street canyons. The near-ground PM2.5 concentration for the worst scenarios could well exceed 100 μg m-3, posing potential health risk to people living and working nearby. In general, older diesel backup generators (i.e., Tier 1, 2 or older) without the up-to-date emission control may significantly increase the pollutant concentration in the near-source street canyons if participating in DR programs. Even generators that comply with Tier-4 standards could lead to PM hotspots if their stacks are next to tall buildings. Our study implies that the siting of diesel backup generators stacks should consider not only the interactions of fresh air intake and exhaust outlet for the building housing the backup generators, but also the dispersion of exhaust plumes in the surrounding environment.

  9. Quasi Path Restoration: A post-failure recovery scheme over pre-allocated backup resource for elastic optical networks

    NASA Astrophysics Data System (ADS)

    Yadav, Dharmendra Singh; Babu, Sarath; Manoj, B. S.

    2018-03-01

    Spectrum conflict during primary and backup routes assignment in elastic optical networks results in increased resource consumption as well as high Bandwidth Blocking Probability. In order to avoid such conflicts, we propose a new scheme, Quasi Path Restoration (QPR), where we divide the available spectrum into two: (1) primary spectrum (for primary routes allocation) and (2) backup spectrum (for rerouting the data on link failures). QPR exhibits three advantages over existing survivable strategies such as Shared Path Protection (SPP), Primary First Fit Backup Last Fit (PFFBLF), Jointly Releasing and re-establishment Defragmentation SPP (JRDSSPP), and Path Restoration (PR): (1) the conflict between primary and backup spectrum during route assignment is completely eliminated, (2) upon a link failure, connection recovery requires less backup resources compared to SPP, PFFBLF, and PR, and (3) availability of the same backup spectrum on each link improves the recovery guarantee. The performance of our scheme is analyzed with different primary backup spectrum partitions on varying connection-request demands and number of frequency slots. Our results show that QPR provides better connection recovery guarantee and Backup Resources Utilization (BRU) compared to bandwidth recovery of PR strategy. In addition, we compare QPR with Shared Path Protection and Primary First-Fit Backup Last Fit strategies in terms of Bandwidth Blocking Probability (BBP) and average frequency slots per connection request. Simulation results show that BBP of SPP, PFFBLF, and JRDSPP varies between 18.59% and 14.42%, while in QPR, BBP ranges from 2.55% to 17.76% for Cost239, NSFNET, and ARPANET topologies. Also, QPR provides bandwidth recovery between 93.61% and 100%, while in PR, the recovery ranges from 86.81% to 98.99%. It is evident from our analysis that QPR provides a reasonable trade-off between bandwidth blocking probability and connection recoverability.

  10. 78 FR 73144 - Acceleration of Broadband Deployment by Improving Wireless Facilities Siting Policies

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-05

    ..., ground-based enclosures, battery back-up power systems, grounding equipment, power transfer switch, and... No. 11-59; FCC 13-122] Acceleration of Broadband Deployment by Improving Wireless Facilities Siting... of new wireless facilities and on rules to implement statutory provisions governing State and local...

  11. View of backup payload specialist Robert Thirsk during Zero-G training

    NASA Image and Video Library

    1984-07-16

    S84-37532 (18 July 1984) --? Robert B. Thirsk, backup payload specialist for 41-G appears to be shaking hands with an unoccupied extravehicular mobility unit (EMU) during a familiarization flight aboard NASA?s KC-135 aircraft. Thirsk, representing Canada?s National Research Council (NRC), serves as backup to Marc Garneau on the seven-member crew for Challenger?s October 1984 flight. This aircraft is used extensively for training and exposing Shuttle crewmembers to weightlessness as well as for evaluation of equipment and experiments scheduled for future flights.

  12. FACILITY 847, DETAIL OF A CENTRAL STAIRWAY FROM COURTYARD, QUADRANGLE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    FACILITY 847, DETAIL OF A CENTRAL STAIRWAY FROM COURTYARD, QUADRANGLE J, VIEW FACING NORTHEAST. - Schofield Barracks Military Reservation, Quadrangles I & J Barracks Type, Between Wright-Smith & Capron Avenues near Williston Avenue, Wahiawa, Honolulu County, HI

  13. 30 CFR 56.14132 - Horns and backup alarms.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ....14132 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Machinery and Equipment Safety Devices and Maintenance Requirements § 56.14132 Horns and backup alarms. (a) Manually...

  14. 30 CFR 56.14132 - Horns and backup alarms.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ....14132 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Machinery and Equipment Safety Devices and Maintenance Requirements § 56.14132 Horns and backup alarms. (a) Manually...

  15. Mineral facilities of Northern and Central Eurasia

    USGS Publications Warehouse

    Baker, Michael S.; Elias, Nurudeen; Guzman, Eric; Soto-Viruet, Yadira

    2010-01-01

    This map displays almost 900 records of mineral facilities within the countries that formerly constituted the Union of Soviet Socialist Republics (USSR). Each record represents one commodity and one facility type at a single geographic location. Facility types include mines, oil and gas fields, and plants, such as refineries, smelters, and mills. Common commodities of interest include aluminum, cement, coal, copper, gold, iron and steel, lead, nickel, petroleum, salt, silver, and zinc. Records include attributes, such as commodity, country, location, company name, facility type and capacity (if applicable), and latitude and longitude geographical coordinates (in both degrees-minutes-seconds and decimal degrees). The data shown on this map and in table 1 were compiled from multiple sources, including (1) the most recently available data from the U.S. Geological Survey (USGS) Minerals Yearbook (Europe and Central Eurasia volume), (2) mineral statistics and information from the USGS Minerals Information Web site (http://minerals.usgs.gov/minerals/pubs/country/europe.html), and (3) data collected by the USGS minerals information country specialists from sources, such as statistical publications of individual countries, annual reports and press releases of operating companies, and trade journals. Data reflect the most recent published table of industry structure for each country at the time of this publication. Additional information is available from the country specialists listed in table 2

  16. FACILITY 847, DETAIL OF A CENTRAL STAIRWELL BETWEEN SECOND AND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    FACILITY 847, DETAIL OF A CENTRAL STAIRWELL BETWEEN SECOND AND THIRD FLOORS, QUADRANGLE J, VIEW FACING SOUTHEAST. - Schofield Barracks Military Reservation, Quadrangles I & J Barracks Type, Between Wright-Smith & Capron Avenues near Williston Avenue, Wahiawa, Honolulu County, HI

  17. Ceramic backup ring prevents undesirable weld-metal buildup

    NASA Technical Reports Server (NTRS)

    Leonard, G. E.

    1971-01-01

    Removable ceramic backup material butted against weld zone back prevents weld metal buildup at that site. Method is successful with manual tungsten-inert gas /TIG/ welding of 316 corrosion resistant steel /CRES/ pieces with 0.76 cm throat diameter and 1.57 cm pipe internal diameter.

  18. Mathematical defense method of networked servers with controlled remote backups

    NASA Astrophysics Data System (ADS)

    Kim, Song-Kyoo

    2006-05-01

    The networked server defense model is focused on reliability and availability in security respects. The (remote) backup servers are hooked up by VPN (Virtual Private Network) with high-speed optical network and replace broken main severs immediately. The networked server can be represent as "machines" and then the system deals with main unreliable, spare, and auxiliary spare machine. During vacation periods, when the system performs a mandatory routine maintenance, auxiliary machines are being used for back-ups; the information on the system is naturally delayed. Analog of the N-policy to restrict the usage of auxiliary machines to some reasonable quantity. The results are demonstrated in the network architecture by using the stochastic optimization techniques.

  19. STS-47 Japanese Payload Specialist Mohri and backups during Homestead training

    NASA Technical Reports Server (NTRS)

    1990-01-01

    STS-47 Endeavour, Orbiter Vehicle (OV) 105, Japanese Payload Specialist Mamoru Mohri (far left), backup Payload Specialist Takao Doi (center), and backup Payload Specialist Chiaki Mukai (right) participate in water survival training at Homestead Air Force Base, Florida. Dockside, Mohri and Mukai wash the salt water from their personalized helmets after a water exercise. The three-day course was attended by the STS-47 prime and alternate payload specialists shortly after they were announced for the scheduled summer of 1992 Spacelab Japan (SLJ) mission. Mohri, Doi, and Mukai all represent the National Space Development Agency of Japan (NASDA).

  20. STS-55 German payload specialists (and backups) in LESs during JSC training

    NASA Technical Reports Server (NTRS)

    1992-01-01

    STS-55 Columbia, Orbiter Vehicle (OV) 102, German payload specialists and backup (alternate) payload specialists, wearing launch and entry suits (LESs), pose for group portrait outside mockup side hatch in JSC's Mockup and Integration Laboratory (MAIL) Bldg 9NE. These payload specialists will support the STS-55 Spacelab Deutsche 2 (SL-D2) mission. It is the second dedicated German (Deutsche) Spacelab flight. Left to right are backup Payload Specialists Renate Brummer and Dr. P. Gerhard Thiele, Payload Specialist 1 Ulrich Walter, and Payload Specialist 2 Hans Schlegel.

  1. Centralization and Decentralization of Schools' Physical Facilities Management in Nigeria

    ERIC Educational Resources Information Center

    Ikoya, Peter O.

    2008-01-01

    Purpose: This research aims to examine the difference in the availability, adequacy and functionality of physical facilities in centralized and decentralized schools districts, with a view to making appropriate recommendations to stakeholders on the reform programmes in the Nigerian education sector. Design/methodology/approach: Principals,…

  2. CAD/CAM transtibial prosthetic sockets from central fabrication facilities: How accurate are they?

    PubMed Central

    Sanders, Joan E.; Rogers, Ellen L.; Sorenson, Elizabeth A.; Lee, Gregory S.; Abrahamson, Daniel C.

    2014-01-01

    This research compares transtibial prosthetic sockets made by central fabrication facilities with their corresponding American Academy of Orthotists and Prosthetists (AAOP) electronic shape files and assesses the central fabrication process. We ordered three different socket shapes from each of 10 manufacturers. Then we digitized the sockets using a very accurate custom mechanical digitizer. Results showed that quality varied considerably among the different manufacturers. Four of the companies consistently made sockets within +/−1.1% volume (approximately 1 sock ply) of the AAOP electronic shape file, while six other companies did not. Six of the companies showed consistent undersizing or oversizing in their sockets, which suggests a consistent calibration or manufacturing error. Other companies showed inconsistent sizing or shape distortion, a difficult problem that represents a most challenging limitation for central fabrication facilities. PMID:18247236

  3. Central Facilities Area Sewage Lagoon Evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cole, Mark R.

    2013-12-01

    The Central Facilities Area (CFA), located in Butte County, Idaho, at the Idaho National Laboratory has an existing wastewater system to collect and treat sanitary wastewater and non-contact cooling water from the facility. The existing treatment facility consists of three cells: Cell #1 has a surface area of 1.7 acres, Cell #2 has a surface area of 10.3 acres, and Cell #3 has a surface area of 0.5 acres. If flows exceed the evaporative capacity of the cells, wastewater is discharged to a 73.5-acre land application site that uses a center-pivot irrigation sprinkler system. As flows at CFA have decreasedmore » in recent years, the amount of wastewater discharged to the land application site has decreased from 13.64 million gallons in 2004 to no discharge in 2012 and 2013. In addition to the decreasing need for land application, approximately 7.7 MG of supplemental water was added to the system in 2013 to maintain a water level and prevent the clay soil liners in the cells from drying out and “cracking.” The Idaho National Laboratory is concerned that the sewage lagoons and land application site may be oversized for current and future flows. A further concern is the sustainability of the large volumes of supplemental water that are added to the system according to current operational practices. Therefore, this study was initiated to evaluate the system capacity, operational practices, and potential improvement alternatives, as warranted.« less

  4. DOMe: A deduplication optimization method for the NewSQL database backups

    PubMed Central

    Wang, Longxiang; Zhu, Zhengdong; Zhang, Xingjun; Wang, Yinfeng

    2017-01-01

    Reducing duplicated data of database backups is an important application scenario for data deduplication technology. NewSQL is an emerging database system and is now being used more and more widely. NewSQL systems need to improve data reliability by periodically backing up in-memory data, resulting in a lot of duplicated data. The traditional deduplication method is not optimized for the NewSQL server system and cannot take full advantage of hardware resources to optimize deduplication performance. A recent research pointed out that the future NewSQL server will have thousands of CPU cores, large DRAM and huge NVRAM. Therefore, how to utilize these hardware resources to optimize the performance of data deduplication is an important issue. To solve this problem, we propose a deduplication optimization method (DOMe) for NewSQL system backup. To take advantage of the large number of CPU cores in the NewSQL server to optimize deduplication performance, DOMe parallelizes the deduplication method based on the fork-join framework. The fingerprint index, which is the key data structure in the deduplication process, is implemented as pure in-memory hash table, which makes full use of the large DRAM in NewSQL system, eliminating the performance bottleneck problem of fingerprint index existing in traditional deduplication method. The H-store is used as a typical NewSQL database system to implement DOMe method. DOMe is experimentally analyzed by two representative backup data. The experimental results show that: 1) DOMe can reduce the duplicated NewSQL backup data. 2) DOMe significantly improves deduplication performance by parallelizing CDC algorithms. In the case of the theoretical speedup ratio of the server is 20.8, the speedup ratio of DOMe can achieve up to 18; 3) DOMe improved the deduplication throughput by 1.5 times through the pure in-memory index optimization method. PMID:29049307

  5. 78 FR 77171 - Proposed Disposal of George H.W. Bush and Clinton Administration Electronic Backup Tapes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-20

    ... NATIONAL ARCHIVES AND RECORDS ADMINISTRATION [NARA-2014-011] Proposed Disposal of George H.W. Bush... George H.W. Bush and Clinton Administration Disaster Recovery Backup Tapes; final agency action. SUMMARY... collection of disaster recovery backup tapes from the George H.W. Bush and Clinton administrations under the...

  6. [Russian treadmill BD-1 as a backup of the NASA TVIS].

    PubMed

    Iarmanova, E N; Kozlovskaia, I B; Bogomolov, V V; Rumiantseva, O N; Sukhachev, V I; Mel'nik, K A

    2006-01-01

    Already during the early ISS increments malfunctioning of NASA TVIS (treadmill with vibration isolation system) posed major problems for regular crew training and particularly scamper, one of the key exercises on the Russian physical training program. During ISS increment-3, TVIS unscheduled repairs took virtually all the training time. In search for TVIS backup, Russian and NASA engineers considered jointly Russian treadmill BD-1, originally designed for Russian "shuttle" Buran and accepted it as a suitable backup in case of complete TVIS failure. To enter into the "dialogue" with BD-1, i.e., to record and downlink training data, the treadmill speed indicator, a part of the treadmill stand, was replaced by PC.

  7. Production planning and backup sourcing strategy of a buyer-dominant supply chain with random yield and demand

    NASA Astrophysics Data System (ADS)

    Chen, Kebing; Xiao, Tiaojun

    2015-11-01

    This paper studies the backup sourcing strategy of the buyer and the production planning of the supplier in presence of both random yield and random demand. Since the production is susceptible to the randomness of yield beyond the control of the supplier, the buyer may access to a backup sourcing option for the finished items. We analyse the value of backup sourcing for both the decentralised and centralised channels. Backup sourcing strategy of the buyer may lower the supply chain's performance. We show that the order quantity of the buyer does not change the stocking factor of the supplier's input. Meanwhile, compared with the centralised operation, the decentralised operation is more dependent on the backup sourcing to reduce supply shortage of the contracting supplier. From the channel's perspective, an incentive scheme is developed to facilitate the coordination of both the buyer and the contracting supplier, we show that the proposed option contract can allow the supply chain members to share the respective risks involved in the production and selling processes. Finally, we also provide qualitative insights based on numerical examples of the centralised and decentralised solutions.

  8. Do familiar teammates request and accept more backup? Transactive memory in air traffic control.

    PubMed

    Smith-Jentsch, Kimberly A; Kraiger, Kurt; Cannon-Bowers, Janis A; Salas, Eduardo

    2009-04-01

    The present study investigated factors that explain when and why different groups of teammates are more likely to request and accept backup from one another when needed in an environment characterized by extreme time pressure and severe consequences of error: commercial air traffic control (ATC). Transactive memory theory states that teammates develop consensus regarding the distribution of their relative expertise as well as confidence in that expertise over time and that this facilitates coordination processes. The present study investigated whether this theory could help to explain between-team differences in requesting and accepting backup when needed. The present study used cross-sectional data collected from 51 commercial ATC teams. Hypotheses were tested using multiple regression analysis. Teammates with greater experience working together requested and accepted backup from one another more than those with lesser experience working together. Teammate knowledge consensus and perceived team efficacy appear to have mediated this relationship. Transactive memory theory extends to high-stress environments in which members' expertise is highly overlapping. Teammates' shared mental models about one another increase the likelihood that they will request and accept backup. Teammate familiarity should be considered when choosing among potential replacement team members. Training strategies that accelerate the development of teammate knowledge consensus and team efficacy are warranted.

  9. Auditory backup alarms: distance-at-first-detection via in-situ experimentation on alarm design and hearing protection effects.

    PubMed

    Alali, Khaled; Casali, John G

    2012-01-01

    The purpose of this study was to assess normal hearing listeners' performance in detecting a stationary backup alarm signal and to quantify the linear distance at detection point. Detection distances for 12 participants with normal hearing were measured while they were fitted with 7 hearing protectors and while they were unoccluded (open ear). A standard (narrowband) backup alarm signal and a broadband (pulsed white noise) backup alarm signal from Brigade[1] were used. The method of limits, with distance as the physical measurement variable and threshold detection as the task, was employed to find at which distance the participant could first detect the backup alarms. A within-subject Analysis of Variance (ANOVA) revealed a significant main effect of the listening conditions on the detection distance in feet. Post hoc analyses indicated that the Bilsom L3HV conventional passive earmuff (at 1132.2 ft detection distance) was significantly poorer compared to all other HPDs and the open ear in detection distance achieved, and that there were no statistically-significant differences between the unoccluded ear (1652.3 ft), EB-15-Lo BlastPLGTM (1546.2 ft), EB-15-Hi BlastPLGTM (1543.4 ft), E-A-R/3M Combat ArmsTM earplug-nonlinear, level-dependent state (1507.8 ft), E-A-R/3M HiFiTM earplug (1497.7 ft), and Bilsom ImpactTM dichotic electronic earmuff (1567.2 ft). In addition, the E-A-R/3M Combat ArmsTM earplug-passive steady state resulted in significantly longer detection distances than only the open ear condition, at 1474.1 ft versus 1652.3 ft for the open ear. ANOVA also revealed a significant main effect of the backup alarm type on detection distance. The means were 1600.9 ft for the standard (narrowband) backup alarm signal, and a significantly closer 1379.4 ft was required for the Brigade broadband backup alarm signal. For on-ground workers, it is crucial to detect backup alarm signals as far away as possible rather than at close distances since this will provide them

  10. BackUp: Development and evaluation of a smart-phone application for coping with suicidal crises

    PubMed Central

    Aerts, Saskia; Muijzers, Ekke; De Jaegere, Eva; van Heeringen, Kees; Portzky, Gwendolyn

    2017-01-01

    Background Suicide is a major public health issue and has large impact on the lives of many people. Innovative technologies such as smartphones could create new possibilities for suicide prevention, such as helping to overcome the barriers and stigma on help seeking in case of suicidal ideation. Due to their omnipresence, smartphone apps can offer suicide prevention tools very fast, they are easily-accessible, low-threshold and can help overcome some of the help-seeking barriers suicidal people experience. This article describes the development, testing and implementation of a mobile application for coping with suicidal crisis: BackUp. Methods Based on the analysis of literature and existing suicide prevention apps several tools were identified as relevant to include in a suicide prevention app. The selected tools (a safety planning tool, a hope box, a coping cards module, and a module to reach out) are evidence based in a face to face context, and could be easily transferred into a mobile app. The testing of existing apps and the literature also revealed important guidelines for the technical development of the application. Results BackUp was developed and tested by an expert panel (n = 9) and a panel of end users (n = 21). Both groups rated BackUp as valuable for suicide prevention. Suicidal ideation of the end user group was measured using the Beck Scale for Suicidal Ideation before and after testing BackUp, and showed a small but non-significant decrease. The majority of the testers used BackUp several times. All tools were evaluated as rather or very useable in times of suicidal crisis. Conclusion BackUp was positively evaluated and indicates that self-help tools can have a positive impact on suicidal ideation. Apps in particular create opportunities in approaching people that are not reached by traditional interventions; on the other hand they can contribute to suicide prevention in addition to regular care. However, more research is needed on the impact and

  11. ELECTRICAL LINES ARRIVE FROM CENTRAL FACILITIES AREA, SOUTH OF MTR. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    ELECTRICAL LINES ARRIVE FROM CENTRAL FACILITIES AREA, SOUTH OF MTR. EXCAVATION RUBBLE IN FOREGROUND. CONTRACTOR CRAFT SHOPS, CRANES, AND OTHER MATERIALS ON SITE. CAMERA FACES EAST, WITH LITTLE BUTTE AND MIDDLE BUTTE IN DISTANCE. INL NEGATIVE NO. 335. Unknown Photographer, 7/1/1950 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID

  12. Back-Up Childcare: A Quality Alternative to Regular Care Which Fosters Resilience in Infants and Toddlers.

    ERIC Educational Resources Information Center

    La Bar, Nicole J.

    To many in the field of early care and education, back-up child care may be viewed as a stressful disruption that could interfere with attachment and be detrimental to continuity of care. This paper attempts to prove that high-quality back-up child care offered by employers actually fosters the development of resiliency in young children by…

  13. Official portrait of STS-65 backup Payload Specialist Jean-Jacques Favier

    NASA Image and Video Library

    1993-09-30

    Official portrait of STS-65 International Microgravity Laboratory 2 (IML-2) backup Payload Specialist Jean-Jacques Favier. Favier is a member of the Centre National D'Etudes Spatiales (CNES), the French space agency.

  14. 30 CFR 75.1101-21 - Back-up water system.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Back-up water system. 75.1101-21 Section 75.1101-21 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY... water system. One fire hose outlet together with a length of hose capable of extending to the belt drive...

  15. 30 CFR 75.1101-21 - Back-up water system.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Back-up water system. 75.1101-21 Section 75.1101-21 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY... water system. One fire hose outlet together with a length of hose capable of extending to the belt drive...

  16. 30 CFR 75.1101-21 - Back-up water system.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Back-up water system. 75.1101-21 Section 75.1101-21 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY... water system. One fire hose outlet together with a length of hose capable of extending to the belt drive...

  17. 30 CFR 75.1101-21 - Back-up water system.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Back-up water system. 75.1101-21 Section 75.1101-21 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY... water system. One fire hose outlet together with a length of hose capable of extending to the belt drive...

  18. 30 CFR 75.1101-21 - Back-up water system.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Back-up water system. 75.1101-21 Section 75.1101-21 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY... water system. One fire hose outlet together with a length of hose capable of extending to the belt drive...

  19. Simulating cloud environment for HIS backup using secret sharing.

    PubMed

    Kuroda, Tomohiro; Kimura, Eizen; Matsumura, Yasushi; Yamashita, Yoshinori; Hiramatsu, Haruhiko; Kume, Naoto

    2013-01-01

    In the face of a disaster hospitals are expected to be able to continue providing efficient and high-quality care to patients. It is therefore crucial for hospitals to develop business continuity plans (BCPs) that identify their vulnerabilities, and prepare procedures to overcome them. A key aspect of most hospitals' BCPs is creating the backup of the hospital information system (HIS) data at multiple remote sites. However, the need to keep the data confidential dramatically increases the costs of making such backups. Secret sharing is a method to split an original secret message so that individual pieces are meaningless, but putting sufficient number of pieces together reveals the original message. It allows creation of pseudo-redundant arrays of independent disks for privacy-sensitive data over the Internet. We developed a secret sharing environment for StarBED, a large-scale network experiment environment, and evaluated its potential and performance during disaster recovery. Simulation results showed that the entire main HIS database of Kyoto University Hospital could be retrieved within three days even if one of the distributed storage systems crashed during a disaster.

  20. Fuel Cell Backup Power Geographical Visualization Map (Fact Sheet)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    2012-12-01

    This NREL Hydrogen and Fuel Cell Technical Highlight describes a time-lapse geographical visualization map of early market use of fuel cells for telecommunications backup power. The map synthesizes data being analyzed by NREL's Technology Validation team for the U.S. Department of Energy (DOE) Fuel Cell Technologies Program with DOE's publicly available annual summaries of electric disturbance events.

  1. Mechanical Backup For Fly-By-Wire Control System

    NASA Technical Reports Server (NTRS)

    Stewart, Eric C.

    1992-01-01

    Mechanical device eliminates need for redundant fly-by-wire subsystems. Main components are two linkages. One connected to control column in conventional, reversible control system. Other slides inside first linkage and connected to pilot's control wheel. In addition to aircraft applications, design used in control systems in which computer control desirable but safety backup systems required; for example, in boat rudders, engine controls in boats and automobiles, and controls in construction equipment.

  2. Visibility of children behind 2010-2013 model year passenger vehicles using glances, mirrors, and backup cameras and parking sensors.

    PubMed

    Kidd, David G; Brethwaite, Andrew

    2014-05-01

    This study identified the areas behind vehicles where younger and older children are not visible and measured the extent to which vehicle technologies improve visibility. Rear visibility of targets simulating the heights of a 12-15-month-old, a 30-36-month-old, and a 60-72-month-old child was assessed in 21 2010-2013 model year passenger vehicles with a backup camera or a backup camera plus parking sensor system. The average blind zone for a 12-15-month-old was twice as large as it was for a 60-72-month-old. Large SUVs had the worst rear visibility and small cars had the best. Increases in rear visibility provided by backup cameras were larger than the non-visible areas detected by parking sensors, but parking sensors detected objects in areas near the rear of the vehicle that were not visible in the camera or other fields of view. Overall, backup cameras and backup cameras plus parking sensors reduced the blind zone by around 90 percent on average and have the potential to prevent backover crashes if drivers use the technology appropriately. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. An audible automobile back-up pedestrian warning device--development and evaluation

    DOT National Transportation Integrated Search

    1976-11-01

    The purpose of the study was to develop and field-test an audible back-up warning device for use on automobiles. Detailed criteria of pedestrian age and hearing ability combined with noise characteristics of typical accident sites provide the basis f...

  4. Distributed intrusion monitoring system with fiber link backup and on-line fault diagnosis functions

    NASA Astrophysics Data System (ADS)

    Xu, Jiwei; Wu, Huijuan; Xiao, Shunkun

    2014-12-01

    A novel multi-channel distributed optical fiber intrusion monitoring system with smart fiber link backup and on-line fault diagnosis functions was proposed. A 1× N optical switch was intelligently controlled by a peripheral interface controller (PIC) to expand the fiber link from one channel to several ones to lower the cost of the long or ultra-long distance intrusion monitoring system and also to strengthen the intelligent monitoring link backup function. At the same time, a sliding window auto-correlation method was presented to identify and locate the broken or fault point of the cable. The experimental results showed that the proposed multi-channel system performed well especially whenever any a broken cable was detected. It could locate the broken or fault point by itself accurately and switch to its backup sensing link immediately to ensure the security system to operate stably without a minute idling. And it was successfully applied in a field test for security monitoring of the 220-km-length national borderline in China.

  5. 2012 Annual Wastewater Reuse Report for the Idaho National Laboratory Site's Central facilities Area Sewage Treatment Plant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mike Lewis

    2013-02-01

    This report describes conditions, as required by the state of Idaho Wastewater Reuse Permit (#LA-000141-03), for the wastewater land application site at Idaho National Laboratory Site’s Central Facilities Area Sewage Treatment Plant from November 1, 2011, through October 31, 2012. The report contains the following information: • Site description • Facility and system description • Permit required monitoring data and loading rates • Status of compliance conditions and activities • Discussion of the facility’s environmental impacts. During the 2012 permit year, no wastewater was land-applied to the irrigation area of the Central Facilities Area Sewage Treatment Plant.

  6. ITER Central Solenoid Module Fabrication

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, John

    The fabrication of the modules for the ITER Central Solenoid (CS) has started in a dedicated production facility located in Poway, California, USA. The necessary tools have been designed, built, installed, and tested in the facility to enable the start of production. The current schedule has first module fabrication completed in 2017, followed by testing and subsequent shipment to ITER. The Central Solenoid is a key component of the ITER tokamak providing the inductive voltage to initiate and sustain the plasma current and to position and shape the plasma. The design of the CS has been a collaborative effort betweenmore » the US ITER Project Office (US ITER), the international ITER Organization (IO) and General Atomics (GA). GA’s responsibility includes: completing the fabrication design, developing and qualifying the fabrication processes and tools, and then completing the fabrication of the seven 110 tonne CS modules. The modules will be shipped separately to the ITER site, and then stacked and aligned in the Assembly Hall prior to insertion in the core of the ITER tokamak. A dedicated facility in Poway, California, USA has been established by GA to complete the fabrication of the seven modules. Infrastructure improvements included thick reinforced concrete floors, a diesel generator for backup power, along with, cranes for moving the tooling within the facility. The fabrication process for a single module requires approximately 22 months followed by five months of testing, which includes preliminary electrical testing followed by high current (48.5 kA) tests at 4.7K. The production of the seven modules is completed in a parallel fashion through ten process stations. The process stations have been designed and built with most stations having completed testing and qualification for carrying out the required fabrication processes. The final qualification step for each process station is achieved by the successful production of a prototype coil. Fabrication of

  7. A central storage facility to reduce pesticide suicides--a feasibility study from India.

    PubMed

    Vijayakumar, Lakshmi; Jeyaseelan, Lakshmanan; Kumar, Shuba; Mohanraj, Rani; Devika, Shanmugasundaram; Manikandan, Sarojini

    2013-09-16

    Pesticide suicides are considered the single most important means of suicide worldwide. Centralized pesticide storage facilities have the possible advantage of delaying access to pesticides thereby reducing suicides. We undertook this study to examine the feasibility and acceptability of a centralized pesticide storage facility as a preventive intervention strategy in reducing pesticide suicides. A community randomized controlled feasibility study using a mixed methods approach involving a household survey; focus group discussions (FGDs) and surveillance were undertaken. The study was carried out in a district in southern India. Eight villages that engaged in floriculture were identified. Using the lottery method two were randomized to be the intervention sites and two villages constituted the control site. Two centralized storage facilities were constructed with local involvement and lockable storage boxes were constructed. The household survey conducted at baseline and one and a half years later documented information on sociodemographic data, pesticide usage, storage and suicides. At baseline 4446 individuals (1097 households) in the intervention and 3307 individuals (782 households) in the control sites were recruited while at follow up there were 4308 individuals (1063 households) in the intervention and 2673 individuals (632 households) in the control sites. There were differences in baseline characteristics and imbalances in the prevalence of suicides between intervention and control sites as this was a small feasibility study.The results from the FGDs revealed that most participants found the storage facility to be both useful and acceptable. In addition to protecting against wastage, they felt that it had also helped prevent pesticide suicides as the pesticides stored here were not as easily and readily accessible. The primary analyses were done on an Intention to Treat basis. Following the intervention, the differences between sites in changes in combined

  8. STS-9 payload specialist Merbold and backup Ockels in training session

    NASA Technical Reports Server (NTRS)

    1983-01-01

    STS-9 payload specialist Ulf Merbold, right, a West German physicist and backup Wubbo Ockels, a Dutch scientist, are pictured in a training session in JSC's Shuttle mockup and integration laboratory. In this view Ockels appears to be showing Merbold how to operate a camera.

  9. 30 CFR 57.14132 - Horns and backup alarms for surface equipment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... NONMETAL MINES Machinery and Equipment Safety Devices and Maintenance Requirements § 57.14132 Horns and backup alarms for surface equipment. (a) Manually-operated horns or other audible warning devices provided on self-propelled mobile equipment as a safety device shall be maintained in a functional...

  10. Apollo 9 backup crew on "Retriever"-Ships

    NASA Image and Video Library

    1968-12-06

    S68-51700 (November 1968) --- The backup crew of the Apollo 9 (Spacecraft 104/ Lunar Module 3/ Saturn 504) space mission stands on the deck of the NASA Motor Vessel Retriever (MVR) prior to participating in water egress training in the Gulf of Mexico. Left to right, are astronauts Charles Conrad Jr. (holding hatch), Richard F. Gordon Jr., and Alan L. Bean. They are standing by the Apollo command module trainer which was used in the exercise. Since this photograph was made, these three astronauts have been named as the prime crew of the Apollo 12 lunar landing mission.

  11. 2011 Annual Wastewater Reuse Report for the Idaho National Laboratory Site’s Central Facilities Area Sewage Treatment Plant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Michael G. Lewis

    2012-02-01

    This report describes conditions, as required by the state of Idaho Wastewater Reuse Permit (LA-000141-03), for the wastewater land application site at Idaho National Laboratory Site's Central Facilities Area Sewage Treatment Plant from November 1, 2010, through October 31, 2011. The report contains the following information: (1) Site description; (2) Facility and system description; (3) Permit required monitoring data and loading rates; (4) Status of special compliance conditions and activities; and (5) Discussion of the facility's environmental impacts. During the 2011 permit year, approximately 1.22 million gallons of treated wastewater was land-applied to the irrigation area at Central Facilities Areamore » Sewage Treatment plant.« less

  12. 26 CFR 31.3406-0 - Outline of the backup withholding regulations.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... incorrect name/TIN combination. (2) Definition of account. (3) Definition of business day. (4) Certain exceptions. (c) Notice regarding an incorrect name/TIN combination. (1) In general. (2) Additional... of receipt. (d) Notice from payors of backup withholding due to an incorrect name/TIN combination. (1...

  13. Multicast backup reprovisioning problem for Hamiltonian cycle-based protection on WDM networks

    NASA Astrophysics Data System (ADS)

    Din, Der-Rong; Huang, Jen-Shen

    2014-03-01

    As networks grow in size and complexity, the chance and the impact of failures increase dramatically. The pre-allocated backup resources cannot provide 100% protection guarantee when continuous failures occur in a network. In this paper, the multicast backup re-provisioning problem (MBRP) for Hamiltonian cycle (HC)-based protection on WDM networks for the link-failure case is studied. We focus on how to recover the protecting capabilities of Hamiltonian cycle against the subsequent link-failures on WDM networks for multicast transmissions, after recovering the multicast trees affected by the previous link-failure. Since this problem is a hard problem, an algorithm, which consists of several heuristics and a genetic algorithm (GA), is proposed to solve it. The simulation results of the proposed method are also given. Experimental results indicate that the proposed algorithm can solve this problem efficiently.

  14. STS-90 M.S. Williams and back-up P.S. Mukai, participate in CEIT

    NASA Technical Reports Server (NTRS)

    1998-01-01

    STS-90 Mission Specialist Dafydd 'Dave' Rhys Williams, M.D., with the Canadian Space Agency, and back-up Payload Specialist Chiaki Mukai, M.D., Ph.D., with the National Space Development Agency of Japan, examine items to be used during the Crew Equipment Interface Test (CEIT) in Kennedy Space Center's (KSC's) Operations and Checkout Building, where the Neurolab payload is undergoing processing. The CEIT gives astronauts an opportunity to get a hands-on look at the payloads with which they will be working on-orbit. STS-90 is scheduled to launch aboard the Shuttle Columbia from KSC on April 2. Investigations during the Neurolab mission will focus on the effects of microgravity on the nervous system. Specifically, experiments will study the adaptation of the vestibular system, the central nervous system, and the pathways that control the ability to sense location in the absence of gravity, as well as the effect of microgravity on a developing nervous system.

  15. Influence of backup bearings and support structure dynamics on the behavior of rotors with active supports

    NASA Technical Reports Server (NTRS)

    Flowers, George T.

    1994-01-01

    Progress over the past year includes the following: A simplified rotor model with a flexible shaft and backup bearings has been developed. A simple rotor model which includes a flexible disk and bearings with clearance has been developed and the dynamics of the model investigated. A rotor model based upon the T-501 engine has been developed which includes backup bearing effects. Parallel simulation runs are being conducted using an ANSYS based finite element model of the T-501. The magnetic bearing test rig is currently floating and dynamics/control tests are being conducted. A paper has been written that documents the work using the T-501 engine model. Work has continued with the simplified model. The finite element model is currently being modified to include the effects of foundation dynamics. A literature search for material on foil bearings has been conducted. A finite element model is being developed for a magnetic bearing in series with a foil backup bearing.

  16. 12. Detail of clutch and backup gasoline engine for powering ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    12. Detail of clutch and backup gasoline engine for powering Stoney gates. Clutch mechanism manufactured by Baldridge Machine Company, Detroit, Michigan, ca. 1910. Instrument to the left records volume of flow through headworks. View looking south towards Stoney gates. Photo by Jet Lowe, HAER, 1989. - Puget Sound Power & Light Company, White River Hydroelectric Project, 600 North River Avenue, Dieringer, Pierce County, WA

  17. 38 CFR 17.230 - Contingency backup to the Department of Defense.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 1 2010-07-01 2010-07-01 false Contingency backup to the Department of Defense. 17.230 Section 17.230 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS... the Department of Defense. (a) Priority care to active duty personnel. The Secretary, during and/or...

  18. 38 CFR 17.230 - Contingency backup to the Department of Defense.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 1 2011-07-01 2011-07-01 false Contingency backup to the Department of Defense. 17.230 Section 17.230 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS... the Department of Defense. (a) Priority care to active duty personnel. The Secretary, during and/or...

  19. 38 CFR 17.230 - Contingency backup to the Department of Defense.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 1 2012-07-01 2012-07-01 false Contingency backup to the Department of Defense. 17.230 Section 17.230 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS... the Department of Defense. (a) Priority care to active duty personnel. The Secretary, during and/or...

  20. 38 CFR 17.230 - Contingency backup to the Department of Defense.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 1 2014-07-01 2014-07-01 false Contingency backup to the Department of Defense. 17.230 Section 17.230 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS... the Department of Defense. (a) Priority care to active duty personnel. The Secretary, during and/or...

  1. 38 CFR 17.230 - Contingency backup to the Department of Defense.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 1 2013-07-01 2013-07-01 false Contingency backup to the Department of Defense. 17.230 Section 17.230 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS... the Department of Defense. (a) Priority care to active duty personnel. The Secretary, during and/or...

  2. Clinical experiences utilizing wireless remote control and an ASP model backup archive for a disaster recovery event

    NASA Astrophysics Data System (ADS)

    Liu, Brent J.; Documet, Luis; Documet, Jorge; Huang, H. K.; Muldoon, Jean

    2004-04-01

    An Application Service Provider (ASP) archive model for disaster recovery for Saint John"s Health Center (SJHC) clinical PACS data has been implemented using a Fault-Tolerant Archive Server at the Image Processing and Informatics Laboratory, Marina del Rey, CA (IPIL) since mid-2002. The purpose of this paper is to provide clinical experiences with the implementation of an ASP model backup archive in conjunction with handheld wireless technologies for a particular disaster recovery scenario, an earthquake, in which the local PACS archive and the hospital are destroyed and the patients are moved from one hospital to another. The three sites involved are: (1) SJHC, the simulated disaster site; (2) IPIL, the ASP backup archive site; and (3) University of California, Los Angeles Medical Center (UCLA), the relocated patient site. An ASP backup archive has been established at IPIL to receive clinical PACS images daily using a T1 line from SJHC for backup and disaster recovery storage. Procedures were established to test the network connectivity and data integrity on a regular basis. In a given disaster scenario where the local PACS archive has been destroyed and the patients need to be moved to a second hospital, a wireless handheld device such as a Personal Digital Assistant (PDA) can be utilized to route images to the second hospital site with a PACS and reviewed by radiologists. To simulate this disaster scenario, a wireless network was implemented within the clinical environment in all three sites: SJHC, IPIL, and UCLA. Upon executing the disaster scenario, the SJHC PACS archive server simulates a downtime disaster event. Using the PDA, the radiologist at UCLA can query the ASP backup archive server at IPIL for PACS images and route them directly to UCLA. Implementation experiences integrating this solution within the three clinical environments as well as the wireless performance are discussed. A clinical downtime disaster scenario was implemented and successfully

  3. OCE NEMP PROGRAM DEVELOPMENT OF CRITERIA FOR PROTECTION OF NIKE-X POWER PLANT AND FACILITIES ELECTRICAL SYSTEMS AGAINST NUCLEAR ELECTROMAGNETIC PULSE EFFECTS.

    DTIC Science & Technology

    technical backup material for the OCE NEMP PROGRAM, Development of Criteria for Protection of NIKE-X Power Plant and Facilities Electrical Systems Against Nuclear Electromagnetic Pulse Effects, Protective MEASURES. (Author)

  4. Recycled Water Reuse Permit Renewal Application for the Central Facilities Area Sewage Treatment Plant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lewis, Mike

    This renewal application for a Recycled Water Reuse Permit is being submitted in accordance with the Idaho Administrative Procedures Act 58.01.17 “Recycled Water Rules” and the Municipal Wastewater Reuse Permit LA-000141-03 for continuing the operation of the Central Facilities Area Sewage Treatment Plant located at the Idaho National Laboratory. The permit expires March 16, 2015. The permit requires a renewal application to be submitted six months prior to the expiration date of the existing permit. For the Central Facilities Area Sewage Treatment Plant, the renewal application must be submitted by September 16, 2014. The information in this application is consistentmore » with the Idaho Department of Environmental Quality’s Guidance for Reclamation and Reuse of Municipal and Industrial Wastewater and discussions with Idaho Department of Environmental Quality personnel.« less

  5. jsc2017e136055 - On a snowy night at Red Square in Moscow, Expedition 54-55 backup crewmember Jeanette Epps of NASA lays flowers at the Kremlin Wall where Russian space icons are interred in traditional pre-launch ceremonies Nov. 30. Looking on are backup

    NASA Image and Video Library

    2017-11-30

    jsc2017e136055 - On a snowy night at Red Square in Moscow, Expedition 54-55 backup crewmember Jeanette Epps of NASA lays flowers at the Kremlin Wall where Russian space icons are interred in traditional pre-launch ceremonies Nov. 30. Looking on are backup crewmembers Sergey Prokopyev of the Russian Federal Space Agency (Roscosmos, left) and Alexander Gerst of the European Space Agency. They are backups to Anton Shkaplerov of Roscosmos, Scott Tingle of NASA and Norishige Kanai of the Japan Aerospace Exploration Agency (JAXA), who will launch from the Baikonur Cosmodrome in Kazakhstan on the Soyuz MS-07 spacecraft Dec. 17 for a five-month mission on the International Space Station...Andrey Shelepin/Gagarin Cosmonaut Training Center.

  6. Feasibility analysis of a hydrogen backup power system for Russian telecom market

    NASA Astrophysics Data System (ADS)

    Borzenko, V. I.; Dunikov, D. O.

    2017-11-01

    We performed feasibility analysis of 10 kW hydrogen backup power system (H2BS) consisting of a water electrolyzer, a metal hydride hydrogen storage and a fuel cell. Capital investments in H2BS are mostly determined by the costs of the PEM electrolyzer, the fuel cell and solid state hydrogen storage materials, for single unit or small series manufacture the cost of AB5-type intermetallic compound can reach 50% of total system cost. Today the capital investments in H2BS are 3 times higher than in conventional lead-acid system of the same capacity. Wide distribution of fuel cell hydrogen vehicles, development of hydrogen infrastructure, and mass production of hydrogen power systems will for sure lower capital investments in fuel cell backup power. Operational expenditures for H2BS is only 15% from the expenditures for lead acid systems, and after 4-5 years of exploitation the total cost of ownership will become lower than for batteries.

  7. Data management integration for biomedical core facilities

    NASA Astrophysics Data System (ADS)

    Zhang, Guo-Qiang; Szymanski, Jacek; Wilson, David

    2007-03-01

    We present the design, development, and pilot-deployment experiences of MIMI, a web-based, Multi-modality Multi-Resource Information Integration environment for biomedical core facilities. This is an easily customizable, web-based software tool that integrates scientific and administrative support for a biomedical core facility involving a common set of entities: researchers; projects; equipments and devices; support staff; services; samples and materials; experimental workflow; large and complex data. With this software, one can: register users; manage projects; schedule resources; bill services; perform site-wide search; archive, back-up, and share data. With its customizable, expandable, and scalable characteristics, MIMI not only provides a cost-effective solution to the overarching data management problem of biomedical core facilities unavailable in the market place, but also lays a foundation for data federation to facilitate and support discovery-driven research.

  8. Apollo 1 Prime and Backup Crews

    NASA Image and Video Library

    1966-04-01

    S66-30238 (1 April 1966) --- The National Aeronautics and Space Administration (NASA) has named these astronauts as the prime crew of the first manned Apollo Space Flight. Left to right, are Edward H. White II, command module pilot; Virgil I. Grissom, mission commander; and Roger B. Chaffee, lunar module pilot. On the second row are the Apollo 1 backup crew members, astronauts David R. Scott, James A. McDivitt and Russell L. Schweickart. EDITOR'S NOTE: Astronauts Grissom, White and Chaffee lost their lives in a Jan. 27, 1967 fire in the Apollo CM during testing at Cape Canaveral. McDivitt, Scott and Schweickart later served as crewmembers for the Apollo 9 Earth-orbital mission, which was one of the important stair-step missions leading up to the Apollo 11 manned lunar landing mission of July 1969.

  9. Utilizing data grid architecture for the backup and recovery of clinical image data.

    PubMed

    Liu, Brent J; Zhou, M Z; Documet, J

    2005-01-01

    Grid Computing represents the latest and most exciting technology to evolve from the familiar realm of parallel, peer-to-peer and client-server models. However, there has been limited investigation into the impact of this emerging technology in medical imaging and informatics. In particular, PACS technology, an established clinical image repository system, while having matured significantly during the past ten years, still remains weak in the area of clinical image data backup. Current solutions are expensive or time consuming and the technology is far from foolproof. Many large-scale PACS archive systems still encounter downtime for hours or days, which has the critical effect of crippling daily clinical operations. In this paper, a review of current backup solutions will be presented along with a brief introduction to grid technology. Finally, research and development utilizing the grid architecture for the recovery of clinical image data, in particular, PACS image data, will be presented. The focus of this paper is centered on applying a grid computing architecture to a DICOM environment since DICOM has become the standard for clinical image data and PACS utilizes this standard. A federation of PACS can be created allowing a failed PACS archive to recover its image data from others in the federation in a seamless fashion. The design reflects the five-layer architecture of grid computing: Fabric, Resource, Connectivity, Collective, and Application Layers. The testbed Data Grid is composed of one research laboratory and two clinical sites. The Globus 3.0 Toolkit (Co-developed by the Argonne National Laboratory and Information Sciences Institute, USC) for developing the core and user level middleware is utilized to achieve grid connectivity. The successful implementation and evaluation of utilizing data grid architecture for clinical PACS data backup and recovery will provide an understanding of the methodology for using Data Grid in clinical image data backup for

  10. Improvement on Main/backup Controller Switching Device of the Nozzle Throat Area Control System for a Turbofan Aero Engine

    NASA Astrophysics Data System (ADS)

    Li, Jie; Duan, Minghu; Yan, Maode; Li, Gang; Li, Xiaohui

    2014-06-01

    A full authority digital electronic controller (FADEC) equipped with a full authority hydro-mechanical backup controller (FAHMBC) is adopted as the nozzle throat area control system (NTACS) of a turbofan aero engine. In order to ensure the switching reliability of the main/backup controller, the nozzle throat area control switching valve was improved from three-way convex desktop slide valve to six-way convex desktop slide valve. Simulation results show that, if malfunctions of FAEDC occur and abnormal signals are outputted from FADEC, NTACS will be seriously influenced by the main/backup controller switching in several working states, while NTACS will not be influenced by using the improved nozzle throat area control switching valve, thus the controller switching process will become safer and smoother and the working reliability of this turbofan aero engine is improved by the controller switching device improvement.

  11. Mapping the Characteristics of Critical Care Facilities: Assessment, Distribution, and Level of Critical Care Facilities from Central India.

    PubMed

    Saigal, Saurabh; Sharma, Jai Prakash; Pakhare, Abhijit; Bhaskar, Santosh; Dhanuka, Sanjay; Kumar, Sanjay; Sabde, Yogesh; Bhattacharya, Pradip; Joshi, Rajnish

    2017-10-01

    In low- and middle-income countries such as India, where health systems are weak, the number of available Critical Care Unit (Intensive Care Unit [ICU]) beds is expected to be low. There is no study from the Indian subcontinent that has reported the characteristics and distribution of existing ICUs. We performed this study to understand the characteristics and distribution of ICUs in Madhya Pradesh (MP) state of Central India. We also aimed to develop a consensus scoring system and internally validate it to define levels of care and to improve health system planning and to strengthen referral networks in the state. We obtained a list of potential ICU facilities from various sources and then performed a cross-sectional survey by visiting each facility and determining characteristics for each facility. We collected variables with respect to infrastructure, human resources, equipment, support services, procedures performed, training courses conducted, and in-place policies or standard operating procedure documents. We identified a total of 123 ICUs in MP. Of 123 ICUs, 35 were level 1 facilities, 74 were level 2 facilities, and only 14 were level 3 facilities. Overall, there were 0.17 facilities per 100,000 population (95* confidence interval [CI] 0.14-0.20 per 100,000 populations). There were a total of 1816 ICU beds in the state, with an average of 2.5 beds per 100,000 population (95* CI 2.4-2.6 per 100,000 population). Of the total number of ICU beds, 250 are in level 1, 1141 are in level 2, and 425 are in level 3 facilities. This amounts to 0.34, 1.57, and 0.59 ICU beds per 100,000 population for levels 1, 2, and 3, respectively. This study could just be an eye opener for our healthcare authorities at both state and national levels to estimate the proportion of ICU beds per lac population. Similar mapping of intensive care services from other States will generate national data that is hitherto unknown.

  12. [For the history of creation of central anatomicopathological facility of the Ministry of Defence].

    PubMed

    Chirskiĭ, V S; Sibirev, S A; Bushurov, S E

    2012-12-01

    The system of anatomicopathological facilities was created in 30s of XX century and first years of the Great Patriotic War. The goal of this system was to increase the effectiveness of Sanitary Corps of the Red Army. These anatomicopathological facilities analyzed causes of death of injured soldiers during all stages of the system of treatment-evacuative support of troops and mistakes made by medical specialists during first aid treatment. Organisational forms of anatomicopathological activity were changed and developed according to acquired battle experience. The main stage of formation of anatomicopathological service of the Red Army, and in fact the finished period in organisational formation of anatomicopathological service, was establishment of Central anatomicopathological facility - main methodological, organisational, coordinating and monioring center of anatomicopathological activity of the Armed Forces of the Russian Federation.

  13. 2013 Annual Wastewater Reuse Report for the Idaho National Laboratory Site’s Central Facilities Area Sewage Treatment Plant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mike Lewis

    2014-02-01

    This report describes conditions, as required by the state of Idaho Wastewater Reuse Permit (#LA-000141-03), for the wastewater land application site at the Idaho National Laboratory Site’s Central Facilities Area Sewage Treatment Plant from November 1, 2012, through October 31, 2013. The report contains, as applicable, the following information: • Site description • Facility and system description • Permit required monitoring data and loading rates • Status of compliance conditions and activities • Discussion of the facility’s environmental impacts. During the 2013 permit year, no wastewater was land-applied to the irrigation area of the Central Facilities Area Sewage Treatment Plantmore » and therefore, no effluent flow volumes or samples were collected from wastewater sampling point WW-014102. However, soil samples were collected in October from soil monitoring unit SU-014101.« less

  14. Comparison of circular orbit and Fourier power series ephemeris representations for backup use by the upper atmosphere research satellite onboard computer

    NASA Technical Reports Server (NTRS)

    Kast, J. R.

    1988-01-01

    The Upper Atmosphere Research Satellite (UARS) is a three-axis stabilized Earth-pointing spacecraft in a low-Earth orbit. The UARS onboard computer (OBC) uses a Fourier Power Series (FPS) ephemeris representation that includes 42 position and 42 velocity coefficients per axis, with position residuals at 10-minute intervals. New coefficients and 32 hours of residuals are uploaded daily. This study evaluated two backup methods that permit the OBC to compute an approximate spacecraft ephemeris in the event that new ephemeris data cannot be uplinked for several days: (1) extending the use of the FPS coefficients previously uplinked, and (2) switching to a simple circular orbit approximation designed and tested (but not implemented) for LANDSAT-D. The FPS method provides greater accuracy during the backup period and does not require additional ground operational procedures for generating and uplinking an additional ephemeris table. The tradeoff is that the high accuracy of the FPS will be degraded slightly by adopting the longer fit period necessary to obtain backup accuracy for an extended period of time. The results for UARS show that extended use of the FPS is superior to the circular orbit approximation for short-term ephemeris backup.

  15. Recommended high-tank temperatures for maintenance of high-tank backup support, Revision 3

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Greager, O.H.

    1964-05-20

    Purpose of this note is to recommend revised curves for the high-tank temperature required to maintain adequate high-tank backup support at the six small reactors. Compliance with the conditions shown on these curves will ensure adequate high-tank flow rates following the simultaneous loss of electric and steam power.

  16. Low Velocity Airdrop Tests of an X-38 Backup Parachute Design

    NASA Technical Reports Server (NTRS)

    Stein, Jenny M.; Machin, Ricardo A.; Wolf, Dean F.; Hillebrandt, F. David

    2007-01-01

    The NASA Johnson Space Center's X-38 program designed a new backup parachute system to recover the 25,000 lb X-38 prototype for the Crew Return Vehicle spacecraft. Due to weight and cost constraints, the main backup parachute design incorporated rapid and low cost fabrication techniques using off-the-shelf materials. Near the vent, the canopy was constructed of continuous ribbons, to provide more damage tolerance. The remainder of the canopy was a constructed with a continuous ringslot design. After cancellation of the X-38 program, the parachute design was resized, built, and drop tested for Natick Soldiers Center's Low Velocity Air Drop (LVAD) program to deliver cargo loads up to 22,000 lbs from altitudes as low as 500 feet above the ground. Drop tests results showed that the 500-foot LVAD parachute deployment conditions cause severe skirt inversion and inflation problems for large parachutes. The bag strip occurred at a high angle of attack, causing skirt inversion before the parachute could inflate. The addition of a short reefing line prevented the skirt inversion. Using a lower porosity in the vent area, than is normally used in large parachutes, improved inflation. The drop testing demonstrated that the parachute design could be refined to meet the requirements for the 500-foot LVAD mission.

  17. Analog neural network control method proposed for use in a backup satellite control mode

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Frigo, J.R.; Tilden, M.W.

    1998-03-01

    The authors propose to use an analog neural network controller implemented in hardware, independent of the active control system, for use in a satellite backup control mode. The controller uses coarse sun sensor inputs. The field of view of the sensors activate the neural controller, creating an analog dead band with respect to the direction of the sun on each axis. This network controls the orientation of the vehicle toward the sunlight to ensure adequate power for the system. The attitude of the spacecraft is stabilized with respect to the ambient magnetic field on orbit. This paper develops a modelmore » of the controller using real-time coarse sun sensor data and a dynamic model of a prototype system based on a satellite system. The simulation results and the feasibility of this control method for use in a satellite backup control mode are discussed.« less

  18. Influence of unbalance levels on nonlinear dynamics of a rotor-backup rolling bearing system

    NASA Astrophysics Data System (ADS)

    Fonseca, Cesar A.; Santos, Ilmar F.; Weber, Hans I.

    2017-04-01

    Rotor drops in magnetic bearing and unbalance in rotors have been objective of study for many years. The combination of these two well-known phenomena led to an interesting chaotic response, when the rotor touches the inner race of the back-up bearing. The present work explores the nonlinear rotor backup bearing dynamics both theoretically and experimentally using a fully instrumented test rig, where the position of shaft, its angular velocity and the contact forces between the shaft and the backup bearing are sampled at 25 kHz. The test rig is built by a removable passive magnetic bearing, which allows for simulation of magnetic bearing failure (loss of carrying capacity and rotor fall). The rotor is studied numerically as well as experimentally. A theoretical approach is given beforehand and supplies the basis of the study. Finally the presented results are commented on the point of view of nonlinear dynamics applied to the practical use. The theoretical and numerical analyses are shown through orbit plots, phase plans, Poincaré maps, force response in time and double sided spectrum. The latter is important to characterize the condition at different levels of unbalance between forward and backward whirl. Our preliminary results indicate that for smaller amount of unbalance the rotor swings at the bottom of the bearing, the more the unbalance increases, other dynamical behavior occur and some can be extremely harmful, since the rotor can be lifted from the contact state and return, starting to impact innumerable times without reaching a steady state.

  19. The Amuesha People of Central Peru: Their Struggle to Survive. IWGIA Document No. 16.

    ERIC Educational Resources Information Center

    Smith, Richard Chase

    In 1742, the national liberation movement led by Juan Santos Atahualpa forced the Franciscan missionaries, their military back-up, and the Spanish colonists they brought, out of central Peru and allowed the Amuesha and Campa peoples of the area to continue determining their own destinies independent of the Spanish and later Peruvian occupational…

  20. Corrosion Control of Central Vehicle Wash Facility Pump Components Using Alternative Alloy Coatings

    DTIC Science & Technology

    2016-07-01

    military installations are es- sential for supporting the readiness of tactical vehicles. Steel wash-rack pumps are vulnerable to accelerated...Management Command (IMCOM). The technical monitors were Daniel J. Dunmire (OUSD(AT&L)), Bernie Rodriguez (IMPW-FM), and Valerie D. Hines (DAIM-ODF...statement Large steel water pumps are used to pump water into the Central Vehicle Wash Facility (CVWF) for vehicle washing at Fort Polk, LA. The interior

  1. The Unparalleled Systems Engineering of MSL's Backup Entry, Descent, and Landing System: Second Chance

    NASA Technical Reports Server (NTRS)

    Roumeliotis, Chris; Grinblat, Jonathan; Reeves, Glenn

    2013-01-01

    Second Chance (SECC) was a bare bones version of Mars Science Laboratory's (MSL) Entry Descent & Landing (EDL) flight software that ran on Curiosity's backup computer, which could have taken over swiftly in the event of a reset of Curiosity's prime computer, in order to land her safely on Mars. Without SECC, a reset of Curiosity's prime computer would have lead to catastrophic mission failure. Even though a reset of the prime computer never occurred, SECC had the important responsibility as EDL's guardian angel, and this responsibility would not have seen such success without unparalleled systems engineering. This paper will focus on the systems engineering behind SECC: Covering a brief overview of SECC's design, the intense schedule to use SECC as a backup system, the verification and validation of the system's "Do No Harm" mandate, the system's overall functional performance, and finally, its use on the fateful day of August 5th, 2012.

  2. Tracer techniques for urine volume determination and urine collection and sampling back-up system

    NASA Technical Reports Server (NTRS)

    Ramirez, R. V.

    1971-01-01

    The feasibility, functionality, and overall accuracy of the use of lithium were investigated as a chemical tracer in urine for providing a means of indirect determination of total urine volume by the atomic absorption spectrophotometry method. Experiments were conducted to investigate the parameters of instrumentation, tracer concentration, mixing times, and methods for incorporating the tracer material in the urine collection bag, and to refine and optimize the urine tracer technique to comply with the Skylab scheme and operational parameters of + or - 2% of volume error and + or - 1% accuracy of amount of tracer added to each container. In addition, a back-up method for urine collection and sampling system was developed and evaluated. This back-up method incorporates the tracer technique for volume determination in event of failure of the primary urine collection and preservation system. One chemical preservative was selected and evaluated as a contingency chemical preservative for the storage of urine in event of failure of the urine cooling system.

  3. System Control Facilities: Head-Ends and Central Processors. A Survey of Technical Requirements for Broadband Cable Teleservices; Volume Four.

    ERIC Educational Resources Information Center

    Smith, Ernest K.; And Others

    The system control facilities in broadband communication systems are discussed in this report. These facilities consist of head-ends and central processors. The first section summarizes technical problems and needs, and the second offers a cursory overview of systems, along with an incidental mention of processors. Section 3 looks at the question…

  4. Elective percutaneous coronary intervention without on-site surgical backup: a community hospital experience.

    PubMed

    Djelmami-Hani, M; Mouanoutoua, Mouatou; Hashim, Abdelazim; Solis, Joaquin; Bergen, Lawrence; Oldridge, Neil; Egbujiobi, Leo C; Allaqaband, Suhail; Akhtar, Masood; Bajwa, Tanvir

    2007-12-01

    The American College of Cardiology guidelines consider elective percutaneous coronary intervention (PCI) without on-site surgical backup (OSB) a Class-III indication. Our objective was to determine the safety of elective PCI without OSB. The study is a prospective analysis of a cohort of patients who underwent elective PCI without OSB at our institution. All patients were at our community satellite institution in Beloit, Wis. Three hundred twenty-one elective interventions were performed (mean age 64 +/-12, 68% male). The prevalence of diabetes and hypertension was 28% and 82.5% respectively. A predefined protocol was designed to transfer patients to a cardiac surgical facility if necessary. An experienced interventional cardiologist reviewed the diagnostic angiograms. Patients with complex lesions were excluded from the study. Any procedure-related death or emergency coronary artery bypass graft surgery. Three hundred eighty-two vessels were stented. Multi-vessel intervention was performed in 61 patients (19%). Only 5% of lesions were type C. Four hundred thirty-seven stents were deployed. IIb-IIIa inhibitors were used in 77 (24%) cases. Procedural success was 99.7%. There were no deaths, myocardial infarctions nor need for urgent target vessel revascularization at 6 months. With careful patient/lesion selection, an experienced interventional cardiologist and a predefined transfer protocol, elective PCI without OSB can be performed safely.

  5. Backup key generation model for one-time password security protocol

    NASA Astrophysics Data System (ADS)

    Jeyanthi, N.; Kundu, Sourav

    2017-11-01

    The use of one-time password (OTP) has ushered new life into the existing authentication protocols used by the software industry. It introduced a second layer of security to the traditional username-password authentication, thus coining the term, two-factor authentication. One of the drawbacks of this protocol is the unreliability of the hardware token at the time of authentication. This paper proposes a simple backup key model that can be associated with the real world applications’user database, which would allow a user to circumvent the second authentication stage, in the event of unavailability of the hardware token.

  6. STS-108 backup crew member Robinson in an M-113

    NASA Technical Reports Server (NTRS)

    2001-01-01

    KENNEDY SPACE CENTER, Fla. -- Astronaut Stephen K. Robinson takes his turn at driving an M-113 armored personnel carrier. Robinson is a backup crew member for the International Space Station Expedition 4 crew, who are flying on Space Shuttle Endeavour as part of mission STS-108. Both the mission crew and Expedition 4 crews are at KSC for Terminal Countdown Demonstration Test activities. The TCDT includes emergency exit from the launch pad and a simulated launch countdown. The 11-day mission will also carry the Multi-Purpose Logistics Module Raffaello, filled with supplies and equipment. STS-108 is scheduled to launch Nov. 29.

  7. Backup of renewable energy for an electrical island: case study of Israeli electricity system--current status.

    PubMed

    Fakhouri, A; Kuperman, A

    2014-01-01

    The paper focuses on the quantitative analysis of Israeli Government's targets of 10% renewable energy penetration by 2020 and determining the desired methodology (models) for assessing the effects on the electricity market, addressing the fact that Israel is an electricity island. The main objective is to determine the influence of achieving the Government's goals for renewable energy penetration on the need for backup in the Israeli electricity system. This work presents the current situation of the Israeli electricity market and the study to be taken in order to assess the undesirable effects resulting from the intermittency of electricity generated by wind and solar power stations as well as presents some solutions to mitigating these phenomena. Future work will focus on a quantitative analysis of model runs and determine the amounts of backup required relative to the amount of installed capacity from renewable resources.

  8. 77 FR 28797 - Redundancy of Communications Systems: Backup Power Private Land Mobile Radio Services: Selection...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-16

    ... Systems: Backup Power Private Land Mobile Radio Services: Selection and Assignment of Frequencies, and... certain rule provisions that are without current legal effect and obsolete. These nonsubstantive revisions... current legal effect and is deleted as obsolete. 2. This Order also deletes a rule providing that UHF...

  9. Backup of Renewable Energy for an Electrical Island: Case Study of Israeli Electricity System—Current Status

    PubMed Central

    Fakhouri, A.; Kuperman, A.

    2014-01-01

    The paper focuses on the quantitative analysis of Israeli Government's targets of 10% renewable energy penetration by 2020 and determining the desired methodology (models) for assessing the effects on the electricity market, addressing the fact that Israel is an electricity island. The main objective is to determine the influence of achieving the Government's goals for renewable energy penetration on the need for backup in the Israeli electricity system. This work presents the current situation of the Israeli electricity market and the study to be taken in order to assess the undesirable effects resulting from the intermittency of electricity generated by wind and solar power stations as well as presents some solutions to mitigating these phenomena. Future work will focus on a quantitative analysis of model runs and determine the amounts of backup required relative to the amount of installed capacity from renewable resources. PMID:24624044

  10. Influence of backup bearings and support structure dynamics on the behavior of rotors with active supports

    NASA Technical Reports Server (NTRS)

    Flowers, George T.

    1994-01-01

    Substantial progress has been made toward the goals of this research effort in the past six months. A simplified rotor model with a flexible shaft and backup bearings has been developed. The model is based upon the work of Ishii and Kirk. Parameter studies of the behavior of this model are currently being conducted. A simple rotor model which includes a flexible disk and bearings with clearance has been developed and the dynamics of the model investigated. The study consists of simulation work coupled with experimental verification. The work is documented in the attached paper. A rotor model based upon the T-501 engine has been developed which includes backup bearing effects. The dynamics of this model are currently being studied with the objective of verifying the conclusions obtained from the simpler models. Parallel simulation runs are being conducted using an ANSYS based finite element model of the T-501.

  11. Recovery from unusual attitudes: HUD vs. back-up display in a static F/A-18 simulator.

    PubMed

    Huber, Samuel W

    2006-04-01

    Spatial disorientation (SD) remains one of the most important causes of fatal fighter aircraft accidents. The aim of this study was to give a recommendation for the use of the head-up display (HUD) or back-up attitude directional indicator (ADI) in a state of spatial disorientation based on the respective performance in an unusual attitude recovery task. Seven fighter pilots joining a conversion course to the F/A-18 participated in this study. Flight time will be presented as range (and mean in parentheses). Total military flight experience of the subjects was 835-1759 h (1412 h). Flight time on the F/A-18 was 41-123 h (70 h). The study was performed in a fixed base F/A-18D Weapons Tactics Trainer. We tested the recovery from 11 unusual attitudes and analyzed decision time (DT), total recovery time (TRT), and error rates for the HUD or the back-up ADI. We found no differences regarding either reaction times or error rates. For the HUD we found a DT (mean +/- SD) of 1.3 +/- 0.4 s, a TRT of 9.1 +/- 4.1 s, and an error rate of 29%. For the ADI the respective values were a DT of 1.4 +/- 0.4 s, a TRT of 8.3 +/- 3.8 s, and an error rate of 27%. Unusual attitude recoveries are performed equally well using the HUD or the back-up ADI. Switching from one instrument to the other during recovery should be avoided since it would probably result in a loss of time without benefit.

  12. Central implementation strategies outperform local ones in improving HIV testing in Veterans Healthcare Administration facilities.

    PubMed

    Goetz, Matthew Bidwell; Hoang, Tuyen; Knapp, Herschel; Burgess, Jane; Fletcher, Michael D; Gifford, Allen L; Asch, Steven M

    2013-10-01

    Pilot data suggest that a multifaceted approach may increase HIV testing rates, but the scalability of this approach and the level of support needed for successful implementation remain unknown. To evaluate the effectiveness of a scaled-up multi-component intervention in increasing the rate of risk-based and routine HIV diagnostic testing in primary care clinics and the impact of differing levels of program support. Three arm, quasi-experimental implementation research study. Veterans Health Administration (VHA) facilities. Persons receiving primary care between June 2009 and September 2011 INTERVENTION: A multimodal program, including a real-time electronic clinical reminder to facilitate HIV testing, provider feedback reports and provider education, was implemented in Central and Local Arm Sites; sites in the Central Arm also received ongoing programmatic support. Control Arm sites had no intervention Frequency of performing HIV testing during the 6 months before and after implementation of a risk-based clinical reminder (phase I) or routine clinical reminder (phase II). The adjusted rate of risk-based testing increased by 0.4 %, 5.6 % and 10.1 % in the Control, Local and Central Arms, respectively (all comparisons, p < 0.01). During phase II, the adjusted rate of routine testing increased by 1.1 %, 6.3 % and 9.2 % in the Control, Local and Central Arms, respectively (all comparisons, p < 0.01). At study end, 70-80 % of patients had been offered an HIV test. Use of clinical reminders, provider feedback, education and social marketing significantly increased the frequency at which HIV testing is offered and performed in VHA facilities. These findings support a multimodal approach toward achieving the goal of having every American know their HIV status as a matter of routine clinical practice.

  13. Experiment Needs and Facilities Study Appendix A Transient Reactor Test Facility (TREAT) Upgrade

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    The TREAT Upgrade effort is designed to provide significant new capabilities to satisfy experiment requirements associated with key LMFBR Safety Issues. The upgrade consists of reactor-core modifications to supply the physics performance needed for the new experiments, an Advanced TREAT loop with size and thermal-hydraulics capabilities needed for the experiments, associated interface equipment for loop operations and handling, and facility modifications necessary to accommodate operations with the Loop. The costs and schedules of the tasks to be accomplished under the TREAT Upgrade project are summarized. Cost, including contingency, is about 10 million dollars (1976 dollars). A schedule for execution ofmore » 36 months has been established to provide the new capabilities in order to provide timely support of the LMFBR national effort. A key requirement for the facility modifications is that the reactor availability will not be interrupted for more than 12 weeks during the upgrade. The Advanced TREAT loop is the prototype for the STF small-bundle package loop. Modified TREAT fuel elements contain segments of graphite-matrix fuel with graded uranium loadings similar to those of STF. In addition, the TREAT upgrade provides for use of STF-like stainless steel-UO{sub 2} TREAT fuel for tests of fully enriched fuel bundles. This report will introduce the Upgrade study by presenting a brief description of the scope, performance capability, safety considerations, cost schedule, and development requirements. This work is followed by a "Design Description". Because greatly upgraded loop performance is central to the upgrade, a description is given of Advanced TREAT loop requirements prior to description of the loop concept. Performance requirements of the upgraded reactor system are given. An extensive discussion of the reactor physics calculations performed for the Upgrade concept study is provided. Adequate physics performance is essential for performance of experiments

  14. A reliable facility location design model with site-dependent disruption in the imperfect information context

    PubMed Central

    Yun, Lifen; Wang, Xifu; Fan, Hongqiang; Li, Xiaopeng

    2017-01-01

    This paper proposes a reliable facility location design model under imperfect information with site-dependent disruptions; i.e., each facility is subject to a unique disruption probability that varies across the space. In the imperfect information contexts, customers adopt a realistic “trial-and-error” strategy to visit facilities; i.e., they visit a number of pre-assigned facilities sequentially until they arrive at the first operational facility or give up looking for the service. This proposed model aims to balance initial facility investment and expected long-term operational cost by finding the optimal facility locations. A nonlinear integer programming model is proposed to describe this problem. We apply a linearization technique to reduce the difficulty of solving the proposed model. A number of problem instances are studied to illustrate the performance of the proposed model. The results indicate that our proposed model can reveal a number of interesting insights into the facility location design with site-dependent disruptions, including the benefit of backup facilities and system robustness against variation of the loss-of-service penalty. PMID:28486564

  15. Facilities and support systems for a 90-day test of a regenerative life support system

    NASA Technical Reports Server (NTRS)

    Malin, R. L.

    1972-01-01

    A 90-day test is reported of a regenerative life support system which was completed in a space station simulator. The long duration of the test and the fact that it was manned, imposed rigid reliability and safety requirements on the facility. Where adequate reliability could not be built into essential facility systems, either backup systems or components were provided. Awareness was intensified by: (1) placing signs on every piece of equipment that could affect the test, (2) painting switches on all breaker panels a bright contrasting color, (3) restricting access to the test control area, and (4) informing personnel in the facility (other than test personnel) of test activities. It is concluded that the basic facility is satisfactory for conducting long-duration manned tests, and it is recommended that all monitor and alarm functions be integrated into a single operation.

  16. Alkali Metal Backup Cooling for Stirling Systems - Experimental Results

    NASA Technical Reports Server (NTRS)

    Schwendeman, Carl; Tarau, Calin; Anderson, William G.; Cornell, Peggy A.

    2013-01-01

    In a Stirling Radioisotope Power System (RPS), heat must be continuously removed from the General Purpose Heat Source (GPHS) modules to maintain the modules and surrounding insulation at acceptable temperatures. The Stirling convertor normally provides this cooling. If the Stirling convertor stops in the current system, the insulation is designed to spoil, preventing damage to the GPHS at the cost of an early termination of the mission. An alkali-metal Variable Conductance Heat Pipe (VCHP) can be used to passively allow multiple stops and restarts of the Stirling convertor. In a previous NASA SBIR Program, Advanced Cooling Technologies, Inc. (ACT) developed a series of sodium VCHPs as backup cooling systems for Stirling RPS. The operation of these VCHPs was demonstrated using Stirling heater head simulators and GPHS simulators. In the most recent effort, a sodium VCHP with a stainless steel envelope was designed, fabricated and tested at NASA Glenn Research Center (GRC) with a Stirling convertor for two concepts; one for the Advanced Stirling Radioisotope Generator (ASRG) back up cooling system and one for the Long-lived Venus Lander thermal management system. The VCHP is designed to activate and remove heat from the stopped convertor at a 19 C temperature increase from the nominal vapor temperature. The 19 C temperature increase from nominal is low enough to avoid risking standard ASRG operation and spoiling of the Multi-Layer Insulation (MLI). In addition, the same backup cooling system can be applied to the Stirling convertor used for the refrigeration system of the Long-lived Venus Lander. The VCHP will allow the refrigeration system to: 1) rest during transit at a lower temperature than nominal; 2) pre-cool the modules to an even lower temperature before the entry in Venus atmosphere; 3) work at nominal temperature on Venus surface; 4) briefly stop multiple times on the Venus surface to allow scientific measurements. This paper presents the experimental

  17. Alkali Metal Backup Cooling for Stirling Systems - Experimental Results

    NASA Technical Reports Server (NTRS)

    Schwendeman, Carl; Tarau, Calin; Anderson, William G.; Cornell, Peggy A.

    2013-01-01

    In a Stirling Radioisotope Power System (RPS), heat must be continuously removed from the General Purpose Heat Source (GPHS) modules to maintain the modules and surrounding insulation at acceptable temperatures. The Stirling convertor normally provides this cooling. If the Stirling convertor stops in the current system, the insulation is designed to spoil, preventing damage to the GPHS at the cost of an early termination of the mission. An alkali-metal Variable Conductance Heat Pipe (VCHP) can be used to passively allow multiple stops and restarts of the Stirling convertor. In a previous NASA SBIR Program, Advanced Cooling Technologies, Inc. (ACT) developed a series of sodium VCHPs as backup cooling systems for Stirling RPS. The operation of these VCHPs was demonstrated using Stirling heater head simulators and GPHS simulators. In the most recent effort, a sodium VCHP with a stainless steel envelope was designed, fabricated and tested at NASA Glenn Research Center (GRC) with a Stirling convertor for two concepts; one for the Advanced Stirling Radioisotope Generator (ASRG) back up cooling system and one for the Long-lived Venus Lander thermal management system. The VCHP is designed to activate and remove heat from the stopped convertor at a 19 degC temperature increase from the nominal vapor temperature. The 19 degC temperature increase from nominal is low enough to avoid risking standard ASRG operation and spoiling of the Multi-Layer Insulation (MLI). In addition, the same backup cooling system can be applied to the Stirling convertor used for the refrigeration system of the Long-lived Venus Lander. The VCHP will allow the refrigeration system to: 1) rest during transit at a lower temperature than nominal; 2) pre-cool the modules to an even lower temperature before the entry in Venus atmosphere; 3) work at nominal temperature on Venus surface; 4) briefly stop multiple times on the Venus surface to allow scientific measurements. This paper presents the experimental

  18. RELAP5-3D Resolution of Known Restart/Backup Issues

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mesina, George L.; Anderson, Nolan A.

    2014-12-01

    The state-of-the-art nuclear reactor system safety analysis computer program developed at the Idaho National Laboratory (INL), RELAP5-3D, continues to adapt to changes in computer hardware and software and to develop to meet the ever-expanding needs of the nuclear industry. To continue at the forefront, code testing must evolve with both code and industry developments, and it must work correctly. To best ensure this, the processes of Software Verification and Validation (V&V) are applied. Verification compares coding against its documented algorithms and equations and compares its calculations against analytical solutions and the method of manufactured solutions. A form of this, sequentialmore » verification, checks code specifications against coding only when originally written then applies regression testing which compares code calculations between consecutive updates or versions on a set of test cases to check that the performance does not change. A sequential verification testing system was specially constructed for RELAP5-3D to both detect errors with extreme accuracy and cover all nuclear-plant-relevant code features. Detection is provided through a “verification file” that records double precision sums of key variables. Coverage is provided by a test suite of input decks that exercise code features and capabilities necessary to model a nuclear power plant. A matrix of test features and short-running cases that exercise them is presented. This testing system is used to test base cases (called null testing) as well as restart and backup cases. It can test RELAP5-3D performance in both standalone and coupled (through PVM to other codes) runs. Application of verification testing revealed numerous restart and backup issues in both standalone and couple modes. This document reports the resolution of these issues.« less

  19. Passive cooling system for liquid metal cooled nuclear reactors with backup coolant flow path

    DOEpatents

    Hunsbedt, Anstein; Boardman, Charles E.

    1993-01-01

    A liquid metal cooled nuclear fission reactor plant having a passive auxiliary safety cooling system for removing residual heat resulting from fuel decay during reactor shutdown, or heat produced during a mishap. This reactor plant is enhanced by a backup or secondary passive safety cooling system which augments the primary passive auxiliary cooling system when in operation, and replaces the primary system when rendered inoperable.

  20. 2015 Annual Wastewater Reuse Report for the Idaho National Laboratory Site’s Central Facilities Area Sewage Treatment Plant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lewis, Michael George

    This report describes conditions, as required by the state of Idaho Wastewater Reuse Permit (#LA-000141-03), for the wastewater land application site at the Idaho National Laboratory Site’s Central Facilities Area Sewage Treatment Plant from November 1, 2014, through October 31, 2015.

  1. 2014 Annual Wastewater Reuse Report for the Idaho National Laboratory Site’s Central Facilities Area Sewage Treatment Plant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lewis, Mike

    This report describes conditions, as required by the state of Idaho Wastewater Reuse Permit (#LA-000141-03), for the wastewater land application site at the Idaho National Laboratory Site’s Central Facilities Area Sewage Treatment Plant from November 1, 2013, through October 31, 2014. The report contains, as applicable, the following information; Site description; Facility and system description; Permit required monitoring data and loading rates; Status of compliance conditions and activities; and Discussion of the facility’s environmental impacts. The current permit expires on March 16, 2015. A permit renewal application was submitted to Idaho Department of Environmental Quality on September 15, 2014. Duringmore » the 2014 permit year, no wastewater was land-applied to the irrigation area of the Central Facilities Area Sewage Treatment Plant and therefore, no effluent flow volumes or samples were collected from wastewater sampling point WW-014102. Seepage testing of the three lagoons was performed between August 26, 2014 and September 22, 2014. Seepage rates from Lagoons 1 and 2 were below the 0.25 inches/day requirement; however, Lagoon 3 was above the 0.25 inches/day. Lagoon 3 has been isolated and is being evaluated for future use or permanent removal from service.« less

  2. Feasibility of a medium-size central cogenerated energy facility, energy management memorandum

    NASA Astrophysics Data System (ADS)

    Porter, R. W.

    1982-09-01

    The thermal-economic feasibility was studied of a medium-size central cogenerated energy facility designed to serve five varied industries. Generation options included one dual-fuel diesel and one gas turbine, both with waste heat boilers, and five fired boilers. Fuels included natural gas, and for the fired-boiler cases, also low-sulphur coal and municipal refuse. The fired-boiler cogeneration systems employed back-pressure steam turbines. For coal and refuse, the option of steam only without cogeneration was also assessed. The refuse-fired cases utilized modular incinerators. The options provided for a wide range of steam and electrical capacities. Deficient steam was assumed generated independently in existing equipment. Excess electrical power over that which could be displaced was assumed sold to Commonwealth Edison Company under PURPA (Public Utility Regulator Policies Act). The facility was assumed operated by a mutually owned corporation formed by the cogenerated power users. The economic analysis was predicted on currently applicable energy-investment tax credits and accelerated depreciation for a January 1985 startup date. Based on 100% equity financing, the results indicated that the best alternative was the modular-incinerator cogeneration system.

  3. High-Temperature Polymer Composites Tested for Hypersonic Rocket Combustor Backup Structure

    NASA Technical Reports Server (NTRS)

    Sutter, James K.; Shin, E. Eugene; Thesken, John C.; Fink, Jeffrey E.

    2005-01-01

    Significant component weight reductions are required to achieve the aggressive thrust-toweight goals for the Rocket Based Combined Cycle (RBCC) third-generation, reusable liquid propellant rocket engine, which is one possible engine for a future single-stage-toorbit vehicle. A collaboration between the NASA Glenn Research Center and Boeing Rocketdyne was formed under the Higher Operating Temperature Propulsion Components (HOTPC) program and, currently, the Ultra-Efficient Engine Technology (UEET) Project to develop carbon-fiber-reinforced high-temperature polymer matrix composites (HTPMCs). This program focused primarily on the combustor backup structure to replace all metallic support components with a much lighter polymer-matrixcomposite- (PMC-) titanium honeycomb sandwich structure.

  4. A Study of the Feasibility of a Centralized Instructional Television Production Facility for Higher Education Institutions in Utah.

    ERIC Educational Resources Information Center

    Toyn, Thomas David

    The author sought to evaluate the feasibility of developing a centralized instructional television (ITV) production facility for institutions of higher learning in the state of Utah. He considered economic factors, availability of qualified personnel, space and physical plant, potential to provide the required service, and the degree of acceptance…

  5. Modification of the Epworth Sleepiness Scale in Central China.

    PubMed

    Zhang, Jin Nong; Peng, Bo; Zhao, Ting Ting; Xiang, Min; Fu, Wei; Peng, Yi

    2011-12-01

    The well-known excessive daytime sleepiness (EDS) assessment, Epworth Sleepiness Scale (ESS), is not consistently qualified for patients with diverse living habits. This study is aimed to build a modified ESS (mESS) and then to verify its feasibility in the assessment of EDS for patients with suspected sleep-disordered breathing (SDB) in central China. A Ten-item Sleepiness Questionnaire (10-ISQ) was built by adding two backup items to the original ESS. Then the 10-ISQ was administered to 122 patients in central China with suspected SDB [among them, 119 cases met the minimal diagnostic criteria for obstructive sleep apnea by sleep study, e.g., apnea and hypopnea index (AHI) ≥ 5 h(-1)] and 117 healthy central Chinese volunteers without SDB. Multivariate exploratory techniques were used for item validation. The unreliable item in the original ESS was replaced by the eligible backup item, thus a modified ESS (mESS) was built, and then verified. Item 8 proved to be the only unreliable item in central Chinese patients, with the least factor loading on the main factor and the lowest item-total correlation both in the 10-ISQ and in the original ESS, deletion of it would increase the Cronbach's alpha (from 0.86 to 0.87 in the 10-ISQ; from 0.83 to 0.85 in the original ESS). The mESS was subsequently built by replacing item 8 in the original ESS with item 10 in the 10-ISQ. Verification with patients' responses revealed that the mESS was a single-factor questionnaire with good internal consistency (Cronbach's alpha = 0.86). The sum score of the mESS not only correlated with AHI (P < 0.01) but was also able to discriminate the severity of obstructive apnea (P < 0.01). Nasal CPAP treatment for severe OSA reduced the score significantly (P < 0.001). The performance of the mESS was poor in evaluating normal subjects. The mESS improves the validity of ESS for our patients. Therefore, it is justified to use it instead of the original one in assessment of EDS for patients with SDB

  6. R2 REGULATED FACILITIES

    EPA Science Inventory

    The Facility Registry System (FRS) is a centrally managed database that identifies facilities, sites or places subject to environmental regulations or of environmental interest. FRS creates high-quality, accurate, and authoritative facility identification records through rigorous...

  7. The MSG Central Facility - A Mission Control System for Windows NT

    NASA Astrophysics Data System (ADS)

    Thompson, R.

    The MSG Central Facility, being developed by Science Systems for EUMETSAT1, represents the first of a new generation of satellite mission control systems, based on the Windows NT operating system. The system makes use of a range of new technologies to provide an integrated environment for the planning, scheduling, control and monitoring of the entire Meteosat Second Generation mission. It supports packetised TM/TC and uses Science System's Space UNiT product to provide automated operations support at both Schedule (Timeline) and Procedure levels. Flexible access to historical data is provided through an operations archive based on ORACLE Enterprise Server, hosted on a large RAID array and off-line tape jukebox. Event driven real-time data distribution is based on the CORBA standard. Operations preparation and configuration control tools form a fully integrated element of the system.

  8. Estimating earthquake-induced failure probability and downtime of critical facilities.

    PubMed

    Porter, Keith; Ramer, Kyle

    2012-01-01

    Fault trees have long been used to estimate failure risk in earthquakes, especially for nuclear power plants (NPPs). One interesting application is that one can assess and manage the probability that two facilities - a primary and backup - would be simultaneously rendered inoperative in a single earthquake. Another is that one can calculate the probabilistic time required to restore a facility to functionality, and the probability that, during any given planning period, the facility would be rendered inoperative for any specified duration. A large new peer-reviewed library of component damageability and repair-time data for the first time enables fault trees to be used to calculate the seismic risk of operational failure and downtime for a wide variety of buildings other than NPPs. With the new library, seismic risk of both the failure probability and probabilistic downtime can be assessed and managed, considering the facility's unique combination of structural and non-structural components, their seismic installation conditions, and the other systems on which the facility relies. An example is offered of real computer data centres operated by a California utility. The fault trees were created and tested in collaboration with utility operators, and the failure probability and downtime results validated in several ways.

  9. Cassini Spacecraft In-Flight Swap to Backup Attitude Control Thrusters

    NASA Technical Reports Server (NTRS)

    Bates, David M.

    2010-01-01

    NASA's Cassini Spacecraft, launched on October 15th, 1997 and arrived at Saturn on June 30th, 2004, is the largest and most ambitious interplanetary spacecraft in history. In order to meet the challenging attitude control and navigation requirements of the orbit profile at Saturn, Cassini is equipped with a monopropellant thruster based Reaction Control System (RCS), a bipropellant Main Engine Assembly (MEA) and a Reaction Wheel Assembly (RWA). In 2008, after 11 years of reliable service, several RCS thrusters began to show signs of end of life degradation, which led the operations team to successfully perform the swap to the backup RCS system, the details and challenges of which are described in this paper. With some modifications, it is hoped that similar techniques and design strategies could be used to benefit other spacecraft.

  10. Brief Survey of TSC Computing Facilities

    DOT National Transportation Integrated Search

    1972-05-01

    The Transportation Systems Center (TSC) has four, essentially separate, in-house computing facilities. We shall call them Honeywell Facility, the Hybrid Facility, the Multimode Simulation Facility, and the Central Facility. In addition to these four,...

  11. The INFN-CNAF Tier-1 GEMSS Mass Storage System and database facility activity

    NASA Astrophysics Data System (ADS)

    Ricci, Pier Paolo; Cavalli, Alessandro; Dell'Agnello, Luca; Favaro, Matteo; Gregori, Daniele; Prosperini, Andrea; Pezzi, Michele; Sapunenko, Vladimir; Zizzi, Giovanni; Vagnoni, Vincenzo

    2015-05-01

    The consolidation of Mass Storage services at the INFN-CNAF Tier1 Storage department that has occurred during the last 5 years, resulted in a reliable, high performance and moderately easy-to-manage facility that provides data access, archive, backup and database services to several different use cases. At present, the GEMSS Mass Storage System, developed and installed at CNAF and based upon an integration between the IBM GPFS parallel filesystem and the Tivoli Storage Manager (TSM) tape management software, is one of the largest hierarchical storage sites in Europe. It provides storage resources for about 12% of LHC data, as well as for data of other non-LHC experiments. Files are accessed using standard SRM Grid services provided by the Storage Resource Manager (StoRM), also developed at CNAF. Data access is also provided by XRootD and HTTP/WebDaV endpoints. Besides these services, an Oracle database facility is in production characterized by an effective level of parallelism, redundancy and availability. This facility is running databases for storing and accessing relational data objects and for providing database services to the currently active use cases. It takes advantage of several Oracle technologies, like Real Application Cluster (RAC), Automatic Storage Manager (ASM) and Enterprise Manager centralized management tools, together with other technologies for performance optimization, ease of management and downtime reduction. The aim of the present paper is to illustrate the state-of-the-art of the INFN-CNAF Tier1 Storage department infrastructures and software services, and to give a brief outlook to forthcoming projects. A description of the administrative, monitoring and problem-tracking tools that play a primary role in managing the whole storage framework is also given.

  12. Characterization and reclamation assessment for the Central Shops Diesel Storage Facility, Savannah River Site, Aiken, South Carolina

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fliermans, C.B.; Hazen, T.C.; Bledsoe, H.

    1993-10-01

    The contamination of subsurface terrestrial environments by organic contaminants is a global phenomenon. The remediation of such environments requires innovative assessment techniques and strategies for successful clean-ups. Central Shops Diesel Storage Facility at Savannah River Site was characterized to determine the extent of subsurface diesel fuel contamination using innovative approaches and effective bioremediation techniques for clean-up of the contaminant plume have been established.

  13. Centralization of dairy farming facilities for improved economics and environmental quality.

    PubMed

    Inaba, Rokuta; Furuichi, Tohru; Komatsu, Toshihiro; Tanikawa, Noboru; Ishii, Kazuei

    2009-01-01

    In Japan, most farm animal excreta has been stored directly on farmland. Runoff from this storage has often caused water pollution. Biogasification is anticipated as an important technology to manage excreta properly, but complex problems hinder its introduction. Economic aspects of management have been especially difficult for dairy farmers. For this study, structural problems regarding introduction of biogasification into dairy farming were identified. Subsequently, a desirable system of dairy farming including biogasification was suggested, and an evaluation model of the financial balance was constructed. A case study using current financial balances of several systems of dairy farming was evaluated using the constructed model and actual data. The systems were based on several policy alternatives including the suggested system mentioned above. Results show that a farmer can obtain sufficient income from a system featuring centralization of dairy housing and biogasification facilities and coordinated management by over six farmers.

  14. Children's response to a commercial back-up warning device.

    PubMed

    Sapien, R E; Widman Roux, J; Fullerton-Gleason, L

    2003-03-01

    To determine preschool children's response to a commercial back-up warning alarm in a mock setting of an automobile backing up. Preschool parking lot in Albuquerque, New Mexico, USA. With subjects acting as their own controls, 33 preschoolers were asked to walk behind a stationary vehicle twice. The first time, the control, no warning sound was emitted from the vehicle. The second time, the vehicle was placed in reverse gear triggering an alarm. Children's responses were recorded by a hidden video camera. Avoidance behavior by the child was considered a positive response. Location and distance to where the response occurred was measured. Thirty three children, 38-61 months, were studied. None responded to the alarm with avoidance behavior but 18 looked toward the vehicle or hesitated in their gait. Although over half of the children acknowledged the warning alarm, the device did not elicit avoidance behavior. Mere acknowledgment of the warning device would not prevent injury.

  15. Emergence of a World Class Atmospheric Science Facility in the Central Himalayan Regions of India

    NASA Astrophysics Data System (ADS)

    Taori, A.; Sunilkumar, S. V.; Pant, P.; Sagar, R.

    A new institute Aryabhatta Research Institute of Observation Sciences ARIES has re-borne in year 2004 when the Department of Science and Technology Govt of India took over the 50 year old State Observatory Nainital situated at 2km above the mean sea level in the Shivalik range of central Himalayas Understanding the importance of Nainital 29 4 N 79 5 E it was decided that prime focus should be to set up a world-class research facility for atmospheric sciences apart from the existing astronomy and astrophysics Reason for the above being the strategic location of Nainital to study the free tropospheric aerosols stratosphere-troposphere exchange monsoon dynamics and atmospheric waves These waves can be seeded by the Himalayan topography and may propagate up to the mesosphere-lower thermosphere altitudes and manifest themselves as an important coupling agent between lower middle and upper atmosphere Advance facilities to study the middle atmospheric dynamics are getting established For this an 84-cm Rayleigh lidar is under development to study the thermal structure of the middle atmosphere which will be commissioned by year 2009 A new project has already been approved to set up a stratosphere-troposphere ST radar facility which will further help understanding the thermal structure and wind field measurements in troposphere-stratosphere altitudes To supplement these several airglow experiments will also be stationed for simultaneous measurements Such facilities are of great importance for coordination with the space borne measurements After

  16. Yeast mitochondrial glutathione is an essential antioxidant with mitochondrial thioredoxin providing a back-up system

    PubMed Central

    Gostimskaya, Irina; Grant, Chris M.

    2016-01-01

    Glutathione is an abundant, low-molecular-weight tripeptide whose biological importance is dependent upon its redox-active free sulphydryl moiety. Its role as the main determinant of thiol-redox control has been challenged such that it has been proposed to play a crucial role in iron–sulphur clusters maturation, and only a minor role in thiol redox regulation, predominantly as a back-up system for the cytoplasmic thioredoxin system. Here, we have tested the importance of mitochondrial glutathione in thiol-redox regulation. Glutathione reductase (Glr1) is an oxidoreductase which converts oxidized glutathione to its reduced form. Yeast Glr1 localizes to both the cytosol and mitochondria and we have used a Glr1M1L mutant that is constitutively localized to the cytosol to test the requirement for mitochondrial Glr1. We show that the loss of mitochondrial Glr1 specifically accounts for oxidant sensitivity of a glr1 mutant. Loss of mitochondrial Glr1 does not influence iron–sulphur cluster maturation and we have used targeted roGFP2 fluorescent probes to show that oxidant sensitivity is linked to an altered redox environment. Our data indicate mitochondrial glutathione is crucial for mitochondrial thiol-redox regulation, and the mitochondrial thioredoxin system provides a back-up system, but cannot bear the redox load of the mitochondria on its own. PMID:26898146

  17. Human-Rated Space Vehicle Backup Flight Systems

    NASA Technical Reports Server (NTRS)

    Davis, Jeffrey A.; Busa, Joseph L.

    2004-01-01

    Human rated space vehicles have historically employed a Backup Flight System (BFS) for the main purpose of mitigating the loss of the primary avionics control system. Throughout these projects, however, the underlying philosophy and technical implementation vary greatly. This paper attempts to coalesce each of the past space vehicle program's BFS design and implementation methodologies with the accompanying underlining philosophical arguments that drove each program to such decisions. The focus will be aimed at Mercury, Gemini, Apollo, and Space Shuttle However, the ideologies and implementation of several commercial and military aircraft are incorporated as well to complete the full breadth view of BFS development across the varying industries. In particular to the non-space based vehicles is the notion of deciding not to utilize a BFS. A diverse analysis of BFS to primary system benefits in terms of reliability against all aspects of project development are reviewed and traded. The risk of engaging the BFS during critical stages of flight (e.g. ascent and entry), the level of capability of the BFS (subset capability of main system vs. equivalent system), and the notion of dissimilar hardware and software design are all discussed. Finally, considerations for employing a BFS on future human-rated space missions are reviewed in light of modern avionics architectures and mission scenarios implicit in exploration beyond low Earth orbit.

  18. A right hemisphere safety backup at work: hypotheses for deep hypnosis, post-traumatic stress disorder, and dissociation identity disorder.

    PubMed

    Burnand, Gordon

    2013-09-01

    Problem theory points to an a priori relation between six key problems of living, to which people have adapted through evolution. Children are guided through the problems one by one, learning to switch between them automatically and unawares. The first problem of raising hope of certainty (about the environment), is dealt with in the right hemisphere (RH). The second of raising hope of freedom (or power to control), is dealt with in the left hemisphere (LH). Here adventurousness and ignoring the goodness of outcomes potentially create recklessness. When uncertainty rises the RH activates a backup with an override that substitutes immobility, takes over sensory inputs, but allows obedience to parental commands, and a cut-out that stops new work on the freedom problem. Support for the use of the backup by infants is found in the immobility that precedes the crying in strange conditions, and in childhood EEGs. The hypothesis that the backup is active in deep hypnosis imposes accord on findings that appear contradictory. For example it accounts for why observations during deep hypnosis emphasize the activity of the RH, but observations of responsive people not under hypnosis emphasize the activity of the LH. The hypothesis that the backup is active in post-traumatic stress disorder (PTSD) is supported by (a) fMRI observations that could reflect the cut-out, in that part of the precuneus has low metabolism, (b) the recall of motionlessness at the time of the trauma, (c) an argument that playing dead as a defence against predators is illogical, (d) the ease of hypnosis. With dissociative identity disorder (DID), the theory is consistent with up to six alters that have executive control and one trauma identity state where childhood traumas are re-experienced. Support for the cut-out affecting the trauma identity state comes from suppression of part of the precuneus and other parts of the parietal lobe when the trauma identity state is salient and a general script about a

  19. Management of adults with acute streptococcal pharyngitis: minimal value for backup strep testing and overuse of antibiotics.

    PubMed

    Nakhoul, Georges N; Hickner, John

    2013-06-01

    Rapid antigen detection tests (RADT) are commonly used to guide appropriate antibiotic treatment of group A beta-hemolytic streptococcal (GABHS) pharyngitis. In adults, there is controversy about the need for routine backup testing of negative RADT. Estimate the costs and benefits in adults of routine backup testing by DNA Gen-probe of negative RADT (Acceava). Observational follow-up study. All patients aged 18 years and older visiting a Cleveland Clinic generalist physician in 2009 and 2010 with a visit diagnosis of acute pharyngitis (ICD codes 462, 034.0). The patients were identified using the Cleveland Clinic Epic Clarity database. We determined the proportion of false negative RADT, antibiotic prescription patterns and rate of serious suppurative complications within 30 days of the office visit. Of 25,130 patients with acute pharyngitis, 19% had no testing and 81% were tested. Of the 15,555 patients that had a negative RADT and follow-up DNA probe, 6% had a positive DNA probe. Of the 953 patients who had a negative RADT and a positive DNA strep probe, 48% received an antibiotic prescription at the time of the visit and 51% received an antibiotic prescription after an average of 2.3 days. Only one patient with a negative RADT and no follow-up DNA probe developed a peritonsillar abscess. Overall, of the 15,555 DNA probes performed, management was altered in only 3% of the patients at a total cost of $1,757,715. Fifty-six percent received an antibiotic while only 19.5% had a confirmed strep throat diagnosis. The false negative rate of Acceava RADT for the diagnosis of GABHS pharyngitis was 6%. We question the benefit of routine DNA probe backup testing in adults because of its substantial cost, an average delay in antibiotic prescribing of over 2 days, and because suppurative complications are very uncommon. We found a high rate of inappropriate antibiotic prescribing.

  20. Thermal control evaluation of a Shuttle Orbiter solar observatory using Skylab ATM backup hardware

    NASA Technical Reports Server (NTRS)

    Class, C. R.; Presta, G.; Trucks, H.

    1975-01-01

    A study under the sponsorship of Marshall Space Flight Center (MSFC) established the feasibility to utilize the Skylab Apollo Telescope Mount (ATM) backup hardware for early low cost Shuttle Orbiter solar observation missions. A solar inertial attitude and a seven-day, full sun exposure were baselined. As a portion of the study, a series of thermal control evaluations were performed to resolve the problems caused by the relocation of the ATM to the Shuttle Orbiter bay and resulting configuration changes. Thermal control requirements, problems, the use of solar shields, Spacelab supplied fluid cooling and component placement are discussed.

  1. Characteristics of a lithium-thionyl chloride battery as a memory back-up power source

    NASA Astrophysics Data System (ADS)

    Iwamaru, T.; Uetani, Y.

    An Li/SOCl 2 battery of R6 size (ER6C) has been evaluated as a memory back-up power source for CMOS RAM. The working voltage is 3.6 V and the discharge capacity is 1900 mA h on a 1OK-ohm load. The cell exhibits satisfactory working voltage and discharge capacity over the temperature range -40 °C to 85 °C. The discharge reaction mechanism has been elucidated. Cumulative self discharge during 10 years discharge at 20 μA is estimated to be 3.5%. No serious problems have been observed during abuse tests.

  2. Referenced-site environmental document for a Monitored Retrievable Storage facility: backup waste management option for handling 1800 MTU per year

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Silviera, D.J.; Aaberg, R.L.; Cushing, C.E.

    This environmental document includes a discussion of the purpose of a monitored retrievable storage facility, a description of two facility design concepts (sealed storage cask and field drywell), a description of three reference sites (arid, warm-wet, and cold-wet), and a discussion and comparison of the impacts associated with each of the six site/concept combinations. This analysis is based on a 15,000-MTU storage capacity and a throughput rate of up to 1800 MTU per year.

  3. Peripherally Inserted Central Catheter Use in Skilled Nursing Facilities: A Pilot Study.

    PubMed

    Chopra, Vineet; Montoya, Ana; Joshi, Darius; Becker, Carol; Brant, Amy; McGuirk, Helen; Clark, Jordyn; Harrod, Molly; Kuhn, Latoya; Mody, Lona

    2015-09-01

    To describe patterns of use, care practices, and outcomes related to peripherally inserted central catheter (PICC) use in skilled nursing facilities (SNFs). Prospective cohort study. Two community SNFs. Adult SNF residents with PICCs (N = 56). Information on indication for PICC use, device characteristics (e.g., lumens, gauge), and participant data (comorbidities, medications) were obtained from medical records. Care practices (e.g., frequency of flushing, dressing care) and problems related to PICCs were recorded. Major (central line-associated bloodstream infection, venous thromboembolism, catheter dislodgement) and minor (migration, dressing disruption, lumen occlusion, exit site infection) complications and process measures (flushing of PICC, assessment of necessity) were recorded. Bivariate analyses with t-tests, chi-square tests, or Fischer exact tests were used for continuous and categorical data. Participants were enrolled from two SNFs. The most common indication for PICC use was intravenous antibiotic delivery. The average PICC dwell time was 43 days, and most devices were single-lumen PICCs. Major and minor complications were common and occurred in 11 (20%) and 18 (32%) participants, respectively. Occlusion (23%, n = 13), accidental dislodgement (12%, n = 7), and dressing disruption (11%, n = 6) were the commonest complications observed. Documentation regarding catheter care practices occurred in 41% of cases. Quality improvement efforts that seek to benchmark practice, identify gaps, and institute efforts to improve PICC care and practice in SNFs appear necessary. © 2015, Copyright the Authors Journal compilation © 2015, The American Geriatrics Society.

  4. Survey of solar thermal test facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Masterson, K.

    The facilities that are presently available for testing solar thermal energy collection and conversion systems are briefly described. Facilities that are known to meet ASHRAE standard 93-77 for testing flat-plate collectors are listed. The DOE programs and test needs for distributed concentrating collectors are identified. Existing and planned facilities that meet these needs are described and continued support for most of them is recommended. The needs and facilities that are suitable for testing components of central receiver systems, several of which are located overseas, are identified. The central contact point for obtaining additional details and test procedures for these facilitiesmore » is the Solar Thermal Test Facilities Users' Association in Albuquerque, N.M. The appendices contain data sheets and tables which give additional details on the technical capabilities of each facility. Also included is the 1975 Aerospace Corporation report on test facilities that is frequently referenced in the present work.« less

  5. Using backup generators for meeting peak electricity demand: a sensitivity analysis on emission controls, location, and health endpoints.

    PubMed

    Gilmore, Elisabeth A; Adams, Peter J; Lave, Lester B

    2010-05-01

    Generators installed for backup power during blackouts could help satisfy peak electricity demand; however, many are diesel generators with nonnegligible air emissions that may damage air quality and human health. The full (private and social) cost of using diesel generators with and without emission control retrofits for fine particulate matter (PM2.5) and nitrogen oxides (NOx) were compared with a new natural gas turbine peaking plant. Lower private costs were found for the backup generators because the capital costs are mostly ascribed to reliability. To estimate the social costs from air quality, the changes in ambient concentrations of ozone (O3) and PM2.5 were modeled using the Particulate Matter Comprehensive Air Quality Model with extensions (PMCAMx) chemical transport model. These air quality changes were translated to their equivalent human health effects using concentration-response functions and then into dollars using estimates of "willingness-to-pay" to avoid ill health. As a case study, 1000 MW of backup generation operating for 12 hr/day for 6 days in each of four eastern U.S. cities (Atlanta, Chicago, Dallas, and New York) was modeled. In all cities, modeled PM2.5 concentrations increased (up to 5 microg/m3) due mainly to primary emissions. Smaller increases and decreases were observed for secondary PM2.5 with more variation between cities. Increases in NOx, emissions resulted in significant nitrate formation (up to 1 microg/m3) in Atlanta and Chicago. The NOx emissions also caused O3 decreases in the urban centers and increases in the surrounding areas. For PM2.5, a social cost of approximately $2/kWh was calculated for uncontrolled diesel generators in highly populated cities but was under 10 cent/kWh with PM2.5 and NOx controls. On a full cost basis, it was found that properly controlled diesel generators are cost-effective for meeting peak electricity demand. The authors recommend NOx and PM2.5 controls.

  6. Optimized Heat Pipe Backup Cooling System Tested with a Stirling Convertor

    NASA Technical Reports Server (NTRS)

    Schwendeman, Carl L.; Tarau, Calin; Schifer, Nicholas A.; Anderson, William G.; Garner, Scott

    2016-01-01

    In a Stirling Radioisotope Power System (RPS), heat must be continuously removed from the General Purpose Heat Source (GPHS) modules to maintain the modules and surrounding insulation at acceptable temperatures. The Stirling convertor normally provides this cooling. If the Stirling convertor stops in the current system, the insulation is designed to spoil, preventing damage to the GPHS at the cost of an early termination of the mission. An alkali-metal variable conductance heat pipe (VCHP) can be used to passively allow multiple stops and restarts of the Stirling convertor by bypassing the heat during stops. In a previous NASA Small Business Innovation Research (SBIR) Program, Advanced Cooling Technologies, Inc. (ACT) developed a series of sodium VCHPs as backup cooling systems for the Stirling RPS. In 2012, one of these VCHPs was successfully tested at NASA Glenn Research Center with a Stirling convertor as an Advanced Stirling Radioisotope Generator (ASRG) backup cooling system. The prototype; however, was not optimized and did not reflect the final heat rejection path. ACT through further funding has developed a semioptimized prototype with the finalized heat path for testing at Glenn with a Stirling convertor. The semioptimized system features a two-phase radiator and is significantly smaller and lighter than the prior prototype to reflect a higher level of flight readiness. The VCHP is designed to activate and remove heat from the GPHS during stoppage with a small temperature increase from the nominal vapor temperature. This small temperature increase from nominal is low enough to avoid risking standard ASRG operation and spoiling of the multilayer insulation (MLI). The VCHP passively allows the Stirling convertor to be turned off multiple times during a mission with potentially unlimited off durations. Having the ability to turn the Stirling off allows for the Stirling to be reset and reduces vibrations on the platform during sensitive measurements or

  7. Expedition 44 backup crew ESA (European Space Agency) astronaut Timothy Peake (left), Russian cosmonaut Yuri Malenchenko (ROSCOSMOS) (center), and NASA astronaut Timothy L. Kopra

    NASA Image and Video Library

    2015-02-19

    JSC2015E053686 (04/30/2015) --- Expedition 44 backup crew ESA (European Space Agency) astronaut Timothy Peake (left), Russian cosmonaut Yuri Malenchenko (ROSCOSMOS) (center), and NASA astronaut Timothy L. Kopra .

  8. Shuttle avionics software development trials: Tribulations and successes, the backup flight system

    NASA Technical Reports Server (NTRS)

    Chevers, E. S.

    1985-01-01

    The development and verification of the Backup Flight System software (BFS) is discussed. The approach taken for the BFS was to develop a very simple and straightforward software program and then test it in every conceivable manner. The result was a program that contained approximately 12,000 full words including ground checkout and the built in test program for the computer. To perform verification, a series of tests was defined using the actual flight type hardware and simulated flight conditions. Then simulated flights were flown and detailed performance analysis was conducted. The intent of most BFS tests was to demonstrate that a stable flightpath could be obtained after engagement from an anomalous initial condition. The extention of the BFS to meet the requirements of the orbital flight test phase is also described.

  9. Optimized Heat Pipe Backup Cooling System Tested with a Stirling Convertor

    NASA Technical Reports Server (NTRS)

    Tarau, Calin; Schwendeman, Carl L.; Schifer, Nicholas A.; Anderson, William G.

    2016-01-01

    Advanced Stirling Radioisotope Generator (ASRG) is an attractive energy system for select space missions, and with the addition of a VCHP, it becomes even more versatile. The ASRG is powered through thermal energy from decaying radioisotopes acting as General Purpose Heat Sources (GPHS). A Stirling engine converts the thermal energy to electrical energy and cools the GPHS [2]. The Stirling convertor must operate continuously to maintain acceptable temperatures of the GPHS and protect their cladding. The addition of alkali metal VCHP allows the Stirling to cycle on and off during a mission and can be used as a backup cooling system. The benefits of being able to turn the Stirling off are: allowing for a restart of the Stirling and reducing vibrations for sensitive measurements. The VCHP addition should also increase the efficiency of the Stirling by providing a uniform temperature distribution at the heat transfer interface into the heater head.

  10. Atmospheric Radiation Measurement Program facilities newsletter, July 2000.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sisterson, D. L.; Holdridge, D. J., ed.

    2000-08-03

    For improved safety in and around the ARM SGP CART site, the ARM Program recently purchased and installed an aircraft detection radar system at the central facility near Lamont, Oklahoma. The new system will enhance safety measures already in place at the central facility. The SGP CART site, especially the central facility, houses several instruments employing laser technology. These instruments are designed to be eye-safe and are not a hazard to personnel at the site or pilots of low-flying aircraft over the site. However, some of the specialized equipment brought to the central facility by visiting scientists during scheduled intensivemore » observation periods (IOPs) might use higher-power laser beams that point skyward to make measurements of clouds or aerosols in the atmosphere. If these beams were to strike the eye of a person in an aircraft flying above the instrument, damage to the person's eyesight could result. During IOPs, CART site personnel have obtained Federal Aviation Administration (FAA) approval to temporarily close the airspace directly over the central facility and keep aircraft from flying into the path of the instrument's laser beam. Information about the blocked airspace is easily transmitted to commercial aircraft, but that does not guarantee that the airspace remains completely plane-free. For this reason, during IOPs in which non-eye-safe lasers were in use in the past, ARM technicians watched for low-flying aircraft in and around the airspace over the central facility. If the technicians spotted such an aircraft, they would manually trigger a safety shutter to block the laser beam's path skyward until the plane had cleared the area.« less

  11. Impact of Distributed Energy Resources on the Reliability of Critical Telecommunications Facilities: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robinson, D. G.; Arent, D. J.; Johnson, L.

    2006-06-01

    This paper documents a probabilistic risk assessment of existing and alternative power supply systems at a large telecommunications office. The analysis characterizes the increase in the reliability of power supply through the use of two alternative power configurations. Failures in the power systems supporting major telecommunications service nodes are a main contributor to significant telecommunications outages. A logical approach to improving the robustness of telecommunication facilities is to increase the depth and breadth of technologies available to restore power during power outages. Distributed energy resources such as fuel cells and gas turbines could provide additional on-site electric power sources tomore » provide backup power, if batteries and diesel generators fail. The analysis is based on a hierarchical Bayesian approach and focuses on the failure probability associated with each of three possible facility configurations, along with assessment of the uncertainty or confidence level in the probability of failure. A risk-based characterization of final best configuration is presented.« less

  12. Benefit of adaptive FEC in shared backup path protected elastic optical network.

    PubMed

    Guo, Hong; Dai, Hua; Wang, Chao; Li, Yongcheng; Bose, Sanjay K; Shen, Gangxiang

    2015-07-27

    We apply an adaptive forward error correction (FEC) allocation strategy to an Elastic Optical Network (EON) operated with shared backup path protection (SBPP). To maximize the protected network capacity that can be carried, an Integer Linear Programing (ILP) model and a spectrum window plane (SWP)-based heuristic algorithm are developed. Simulation results show that the FEC coding overhead required by the adaptive FEC scheme is significantly lower than that needed by a fixed FEC allocation strategy resulting in higher network capacity for the adaptive strategy. The adaptive FEC allocation strategy can also significantly outperform the fixed FEC allocation strategy both in terms of the spare capacity redundancy and the average FEC coding overhead needed per optical channel. The proposed heuristic algorithm is efficient and not only performs closer to the ILP model but also does much better than the shortest-path algorithm.

  13. EPA Facility Registry System (FRS): NEPT

    EPA Pesticide Factsheets

    This web feature service contains location and facility identification information from EPA's Facility Registry System (FRS) for the subset of facilities that link to the National Environmental Performance Track (NEPT) Program dataset. FRS identifies and geospatially locates facilities, sites or places subject to environmental regulations or of environmental interest. Using vigorous verification and data management procedures, FRS integrates facility data from EPA's national program systems, other federal agencies, and State and tribal master facility records and provides EPA with a centrally managed, single source of comprehensive and authoritative information on facilities. Additional information on FRS is available at the EPA website https://www.epa.gov/enviro/facility-registry-service-frs

  14. EPA Facility Registry Service (FRS): NEI

    EPA Pesticide Factsheets

    This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link to the National Emissions Inventory (NEI) Program dataset. FRS identifies and geospatially locates facilities, sites or places subject to environmental regulations or of environmental interest. Using vigorous verification and data management procedures, FRS integrates facility data from EPA's national program systems, other federal agencies, and State and tribal master facility records and provides EPA with a centrally managed, single source of comprehensive and authoritative information on facilities. Additional information on FRS is available at the EPA website https://www.epa.gov/enviro/facility-registry-service-frs

  15. Facility Registry Service (FRS)

    EPA Pesticide Factsheets

    This is a centrally managed database that identifies facilities either subject to environmental regulations or of environmental interest, providing an integrated source of air, water, and waste environmental data.

  16. Coronary revascularization in Japan. Part 2: comparison of facilities between 1997 and 1999.

    PubMed

    Tsuchihashi, M; Tsutsui, H; Shihara, M; Shigematsu, H; Yamamoto, S; Koike, G; Kono, S; Takeshita, A

    2001-12-01

    A nation-wide survey on the procedures and facilities of coronary revascularization, percutaneous coronary intervention (PCI) and coronary artery bypass grafting (CABG) conducted by the Japanese Coronary Intervention Study (JCIS) group during 1997 revealed that PCI is more often used than CABG and is mainly carried out in low-volume facilities without surgical backup. The present study aimed to investigate the temporal changes in the usage of revascularization therapies and facilities from 1997 to 1999. A questionnaire was mailed in 1998 to the delegates of 1,086 PCI and 582 CABG facilities identified by the previous survey, and 89% of PCIs surveyed and 94% of CABGs surveyed reported back. The number of PCI procedures had increased by 19% from 97,831 to 116,479 and that of CABG procedures also increased by 21% from 16,374 to 19,846. The ratio of PCI to CABG was 5.9 in 1999, showing no significant change from 6.0 in 1997. In parallel, the number of PCI and CABG facilities increased from 888 to 941 and from 442 to 453, respectively. The use of coronary stents and other interventional devices increased during these 2 years. Coronary stents were used regardless of the annual procedural volume of the facilities, whereas other interventional devices, directional and rotational coronary atherectomy, were used mainly in the high-volume laboratories (p<0.01). Beating-heart, off-pump CABG had increased from 2% to 11% of total cases. Continued monitoring of trends in PCI and CABG facilities and procedures will be needed for nation-wide assessment of the use of new technology.

  17. High energy diode-pumped solid-state laser development at the Central Laser Facility

    NASA Astrophysics Data System (ADS)

    Mason, Paul D.; Banerjee, Saumyabrata; Ertel, Klaus; Phillips, P. Jonathan; Butcher, Thomas; Smith, Jodie; De Vido, Mariastefania; Chekhlov, Oleg; Hernandez-Gomez, Cristina; Edwards, Chris; Collier, John

    2016-04-01

    In this paper we review the development of high energy, nanosecond pulsed diode-pumped solid state lasers within the Central Laser Facility (CLF) based on cryogenic gas cooled multi-slab ceramic Yb:YAG amplifier technology. To date two 10J-scale systems, the DiPOLE prototype amplifier and an improved DIPOLE10 system, have been developed, and most recently a larger scale system, DiPOLE100, designed to produce 100 J pulses at up to 10 Hz. These systems have demonstrated amplification of 10 ns duration pulses at 1030 nm to energies in excess of 10 J at 10 Hz pulse repetition rate, and over 100 J at 1 Hz, with optical-to-optical conversion efficiencies of up to 27%. We present an overview of the cryo-amplifier concept and compare the design features of these three systems, including details of the amplifier designs, gain media, diode pump lasers and the cryogenic gas cooling systems. The most recent performance results from the three systems are presented along with future plans for high energy DPSSL development within the CLF.

  18. Influence of backup bearings and support structure dynamics on the behavior of rotors with active supports

    NASA Technical Reports Server (NTRS)

    Flowers, George T.

    1995-01-01

    This semiannual status report lists specific accomplishments made on the research of the influence of backup bearings and support structure dynamics on the behavior of rotors with active supports. Papers have been presented representing work done on the T-501 engine model; an experimental/simulation study of auxiliary bearing rotordynamics; and a description of a rotordynamical model for a magnetic bearing supported rotor system, including auxiliary bearing effects. A finite element model for a foil bearing has been developed. Additional studies of rotor/bearing/housing dynamics are currently being performed as are studies of the effects of sideloading on auxiliary bearing rotordynamics using the magnetic bearing supported rotor model.

  19. STS-52 PS MacLean, backup PS Tryggvason, and PI pose on JSC's CCT flight deck

    NASA Technical Reports Server (NTRS)

    1992-01-01

    STS-52 Columbia, Orbiter Vehicle (OV) 102, Canadian Payload Specialist (PS) Steven G. MacLean (left) and backup Payload Specialist Bjarni V. Tryggvason (right) take a break from a camera training session in JSC's Crew Compartment Trainer (CCT). The two Canadian Space Agency (CSA) representatives pose on the CCT's aft flight deck with Canadian scientist David Zimick, the principal investigator (PI) for the materials experiment in low earth orbit (MELEO). MELEO is a component of the CANEX-2 experiment package, manifest to fly on the scheduled October 1992 STS-52 mission. The CCT is part of the shuttle Mockup and Integration Laboratory (MAIL) Bldg 9NE.

  20. Wireless remote monitoring of critical facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tsai, Hanchung; Anderson, John T.; Liu, Yung Y.

    A method, apparatus, and system are provided for monitoring environment parameters of critical facilities. A Remote Area Modular Monitoring (RAMM) apparatus is provided for monitoring environment parameters of critical facilities. The RAMM apparatus includes a battery power supply and a central processor. The RAMM apparatus includes a plurality of sensors monitoring the associated environment parameters and at least one communication module for transmitting one or more monitored environment parameters. The RAMM apparatus is powered by the battery power supply, controlled by the central processor operating a wireless sensor network (WSN) platform when the facility condition is disrupted. The RAMM apparatusmore » includes a housing prepositioned at a strategic location, for example, where a dangerous build-up of contamination and radiation may preclude subsequent manned entrance and surveillance.« less

  1. Impact of Distributed Energy Resources on the Reliability of a Critical Telecommunications Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robinson, D.; Atcitty, C.; Zuffranieri, J.

    2006-03-01

    Telecommunications has been identified by the Department of Homeland Security as a critical infrastructure to the United States. Failures in the power systems supporting major telecommunications service nodes are a main contributor to major telecommunications outages, as documented by analyses of Federal Communications Commission (FCC) outage reports by the National Reliability Steering Committee (under auspices of the Alliance for Telecommunications Industry Solutions). There are two major issues that are having increasing impact on the sensitivity of the power distribution to telecommunication facilities: deregulation of the power industry, and changing weather patterns. A logical approach to improve the robustness of telecommunicationmore » facilities would be to increase the depth and breadth of technologies available to restore power in the face of power outages. Distributed energy resources such as fuel cells and gas turbines could provide one more onsite electric power source to provide backup power, if batteries and diesel generators fail. But does the diversity in power sources actually increase the reliability of offered power to the office equipment, or does the complexity of installing and managing the extended power system induce more potential faults and higher failure rates? This report analyzes a system involving a telecommunications facility consisting of two switch-bays and a satellite reception system.« less

  2. The data storage grid: the next generation of fault-tolerant storage for backup and disaster recovery of clinical images

    NASA Astrophysics Data System (ADS)

    King, Nelson E.; Liu, Brent; Zhou, Zheng; Documet, Jorge; Huang, H. K.

    2005-04-01

    Grid Computing represents the latest and most exciting technology to evolve from the familiar realm of parallel, peer-to-peer and client-server models that can address the problem of fault-tolerant storage for backup and recovery of clinical images. We have researched and developed a novel Data Grid testbed involving several federated PAC systems based on grid architecture. By integrating a grid computing architecture to the DICOM environment, a failed PACS archive can recover its image data from others in the federation in a timely and seamless fashion. The design reflects the five-layer architecture of grid computing: Fabric, Resource, Connectivity, Collective, and Application Layers. The testbed Data Grid architecture representing three federated PAC systems, the Fault-Tolerant PACS archive server at the Image Processing and Informatics Laboratory, Marina del Rey, the clinical PACS at Saint John's Health Center, Santa Monica, and the clinical PACS at the Healthcare Consultation Center II, USC Health Science Campus, will be presented. The successful demonstration of the Data Grid in the testbed will provide an understanding of the Data Grid concept in clinical image data backup as well as establishment of benchmarks for performance from future grid technology improvements and serve as a road map for expanded research into large enterprise and federation level data grids to guarantee 99.999 % up time.

  3. Evaluation of a hybrid paper-electronic medication management system at a residential aged care facility.

    PubMed

    Elliott, Rohan A; Lee, Cik Yin; Hussainy, Safeera Y

    2016-06-01

    Objectives The aims of the study were to investigate discrepancies between general practitioners' paper medication orders and pharmacy-prepared electronic medication administration charts, back-up paper charts and dose-administration aids, as well as delays between prescribing, charting and administration, at a 90-bed residential aged care facility that used a hybrid paper-electronic medication management system. Methods A cross-sectional audit of medication orders, medication charts and dose-administration aids was performed to identify discrepancies. In addition, a retrospective audit was performed of delays between prescribing and availability of an updated electronic medication administration chart. Medication administration records were reviewed retrospectively to determine whether discrepancies and delays led to medication administration errors. Results Medication records for 88 residents (mean age 86 years) were audited. Residents were prescribed a median of eight regular medicines (interquartile range 5-12). One hundred and twenty-five discrepancies were identified. Forty-seven discrepancies, affecting 21 (24%) residents, led to a medication administration error. The most common discrepancies were medicine omission (44.0%) and extra medicine (19.2%). Delays from when medicines were prescribed to when they appeared on the electronic medication administration chart ranged from 18min to 98h. On nine occasions (for 10% of residents) the delay contributed to missed doses, usually antibiotics. Conclusion Medication discrepancies and delays were common. Improved systems for managing medication orders and charts are needed. What is known about the topic? Hybrid paper-electronic medication management systems, in which prescribers' orders are transcribed into an electronic system by pharmacy technicians and pharmacists to create medication administration charts, are increasingly replacing paper-based medication management systems in Australian residential aged care

  4. Decentralized School vs. Centralized School. Investigation No. 3.

    ERIC Educational Resources Information Center

    Paseur, C. Herbert

    A report is presented of a comparative investigation of a decentralized and a centralized school facility. Comparative data are provided regarding costs of the facilities, amount of educational area provided by the facilities, and types of educational areas provided. Evaluative comments are included regarding cost savings versus educational…

  5. Back-Up/ Peak Shaving Fuel Cell System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Staudt, Rhonda L.

    2008-05-28

    This Final Report covers the work executed by Plug Power from 8/11/03 – 10/31/07 statement of work for Topic 2: advancing the state of the art of fuel cell technology with the development of a new generation of commercially viable, stationary, Back-up/Peak-Shaving fuel cell systems, the GenCore II. The Program cost was $7.2 M with the Department of Energy share being $3.6M and Plug Power’s share being $3.6 M. The Program started in August of 2003 and was scheduled to end in January of 2006. The actual program end date was October of 2007. A no cost extension was grated.more » The Department of Energy barriers addressed as part of this program are: Technical Barriers for Distributed Generation Systems: o Durability o Power Electronics o Start up time Technical Barriers for Fuel Cell Components: o Stack Material and Manufacturing Cost o Durability o Thermal and water management Background The next generation GenCore backup fuel cell system to be designed, developed and tested by Plug Power under the program is the first, mass-manufacturable design implementation of Plug Power’s GenCore architected platform targeted for battery and small generator replacement applications in the telecommunications, broadband and UPS markets. The next generation GenCore will be a standalone, H2 in-DC-out system. In designing the next generation GenCore specifically for the telecommunications market, Plug Power is teaming with BellSouth Telecommunications, Inc., a leading industry end user. The final next generation GenCore system is expected to represent a market-entry, mass-manufacturable and economically viable design. The technology will incorporate: • A cost-reduced, polymer electrolyte membrane (PEM) fuel cell stack tailored to hydrogen fuel use • An advanced electrical energy storage system • A modular, scalable power conditioning system tailored to market requirements • A scaled-down, cost-reduced balance of plant (BOP) • Network Equipment Building Standards

  6. EPA Facility Registry Service (FRS): OIL

    EPA Pesticide Factsheets

    This dataset contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link to the Oil database. The Oil database contains information on Spill Prevention, Control, and Countermeasure (SPCC) and Facility Response Plan (FRP) subject facilities to prevent and respond to oil spills. FRP facilities are referred to as substantial harm facilities due to the quantities of oil stored and facility characteristics. FRS identifies and geospatially locates facilities, sites or places subject to environmental regulations or of environmental interest. Using vigorous verification and data management procedures, FRS integrates facility data from EPA's national program systems, other federal agencies, and State and tribal master facility records and provides EPA with a centrally managed, single source of comprehensive and authoritative information on facilities. This data set contains the subset of FRS integrated facilities that link to Oil facilities once the Oil data has been integrated into the FRS database. Additional information on FRS is available at the EPA website https://www.epa.gov/enviro/facility-registry-service-frs.

  7. Backup control airstart performance on a digital electronic engine control-equipped F100-engine

    NASA Technical Reports Server (NTRS)

    Johnson, J. B.

    1984-01-01

    The air start capability of a backup control (BUC) was tested for a digital electronic engine control (DEEC) equipped F100 engine, which was installed in an F-15 aircraft. Two air start schedules were tested. Using the group 1 start schedule, based on a 40 sec timer, an air speed of 300 knots was required to ensure successful 40 and 25% BUC mode spooldown airstarts. If core rotor speed (N2) was less than 40% a stall would occur when the start bleed closed, 40 sec after initiation of the air start. All jet fuel starter (JFS) assisted air starts were successful with the group 1 start schedule. For the group 2 schedule, the time between pressurization and start bleed closure ranged between 50 sec and 72 sec. Idle rps was lower than the desired 65% for air starts at higher altitudes and lower air speeds.

  8. Impact of distributed energy resources on the reliability of a critical telecommunications facility.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robinson, David; Zuffranieri, Jason V.; Atcitty, Christopher B.

    2006-03-01

    This report documents a probabilistic risk assessment of an existing power supply system at a large telecommunications office. The focus is on characterizing the increase in the reliability of power supply through the use of two alternative power configurations. Telecommunications has been identified by the Department of Homeland Security as a critical infrastructure to the United States. Failures in the power systems supporting major telecommunications service nodes are a main contributor to major telecommunications outages. A logical approach to improve the robustness of telecommunication facilities would be to increase the depth and breadth of technologies available to restore power inmore » the face of power outages. Distributed energy resources such as fuel cells and gas turbines could provide one more onsite electric power source to provide backup power, if batteries and diesel generators fail. The analysis is based on a hierarchical Bayesian approach and focuses on the failure probability associated with each of three possible facility configurations, along with assessment of the uncertainty or confidence level in the probability of failure. A risk-based characterization of final best configuration is presented.« less

  9. Impact of strong climate change on balancing and storage needs in a fully renewable energy system

    NASA Astrophysics Data System (ADS)

    Weber, Juliane; Wohland, Jan; Witthaut, Dirk

    2017-04-01

    We investigate the impact of strong climate change on a European energy system dominated by wind power. No robust trend can be observed regarding the change of the wind power yield for most countries in Europe. However, intra-annual variabilities in wind power generation robustly increase in most of Central and Western Europe and decrease in Spain, Portugal and Greece by the end of this century. Thus, the generation of wind power tends to increase (decrease) in the winter months compared to the summer months. Due to higher (lower) intra-annual variations, the probability for extreme events with long periods of low power production increases (decreases) in summer. This implies that more (less) energy has to be provided by backup power plants. Our simulations are based on the results of five different Global Climate Models (GCMs) using the Representative Concentration Pathway scenario 8.5 (RCP8.5). These results are dynamically downscaled with the regional atmospheric model RCA4 by the EURO-CORDEX initiative (Coordinated Downscaling Experiment - European Domain). A comparison was made between historical data (1970-2000) and mid-century (2030-2060) and end-of-century (2070-2100) data, respectively. For all timeframes we made the assumption that a certain amount of energy is provided by wind power plants. This implies that changes in wind power potentials are neglected and only temporal effects are considered. Wind speed time series are converted to power generation time series using an extrapolation to hub height and a standardized power curve. Assuming a scenario for the future distribution of wind turbines, we obtain a wind power generation time series aggregated on a national level. The operation of backup power plants and storage facilities is simulated on coarse scales assuming an optimal storage strategy. Backup is required whenever the storage facilities are empty. The amount of change of the backup energy depends on the storage capacity - the higher the

  10. The development and operation of the international solar-terrestrial physics central data handling facility

    NASA Technical Reports Server (NTRS)

    Lehtonen, Kenneth

    1994-01-01

    The National Aeronautics and Space Administration (NASA) Goddard Space Flight Center (GSFC) International Solar-Terrestrial Physics (ISTP) Program is committed to the development of a comprehensive, multi-mission ground data system which will support a variety of national and international scientific missions in an effort to study the flow of energy from the sun through the Earth-space environment, known as the geospace. A major component of the ISTP ground data system is an ISTP-dedicated Central Data Handling Facility (CDHF). Acquisition, development, and operation of the ISTP CDHF were delegated by the ISTP Project Office within the Flight Projects Directorate to the Information Processing Division (IPD) within the Mission Operations and Data Systems Directorate (MO&DSD). The ISTP CDHF supports the receipt, storage, and electronic access of the full complement of ISTP Level-zero science data; serves as the linchpin for the centralized processing and long-term storage of all key parameters generated either by the ISTP CDHF itself or received from external, ISTP Program approved sources; and provides the required networking and 'science-friendly' interfaces for the ISTP investigators. Once connected to the ISTP CDHF, the online catalog of key parameters can be browsed from their remote processing facilities for the immediate electronic receipt of selected key parameters using the NASA Science Internet (NSI), managed by NASA's Ames Research Center. The purpose of this paper is twofold: (1) to describe how the ISTP CDHF was successfully implemented and operated to support initially the Japanese Geomagnetic Tail (GEOTAIL) mission and correlative science investigations, and (2) to describe how the ISTP CDHF has been enhanced to support ongoing as well as future ISTP missions. Emphasis will be placed on how various project management approaches were undertaken that proved to be highly effective in delivering an operational ISTP CDHF to the Project on schedule and

  11. Quality Assurance Project Plan for Closure of the Central Facilities Area Sewage Treatment Plant Lagoon 3 and Land Application Area

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lewis, Michael G.

    This quality assurance project plan describes the technical requirements and quality assurance activities of the environmental data collection/analyses operations to close Central Facilities Area Sewage treatment Plant Lagoon 3 and the land application area. It describes the organization and persons involved, the data quality objectives, the analytical procedures, and the specific quality control measures to be employed. All quality assurance project plan activities are implemented to determine whether the results of the sampling and monitoring performed are of the right type, quantity, and quality to satisfy the requirements for closing Lagoon 3 and the land application area.

  12. EPA Facility Registry Service (FRS): CERCLIS

    EPA Pesticide Factsheets

    This data provides location and attribute information on Facilities regulated under the Comprehensive Environmental Responsibility Compensation and Liability Information System (CERCLIS) for a intranet web feature service . The data provided in this service are obtained from EPA's Facility Registry Service (FRS). The FRS is an integrated source of comprehensive (air, water, and waste) environmental information about facilities, sites or places. This service connects directly to the FRS database to provide this data as a feature service. FRS creates high-quality, accurate, and authoritative facility identification records through rigorous verification and management procedures that incorporate information from program national systems, state master facility records, data collected from EPA's Central Data Exchange registrations and data management personnel. Additional Information on FRS is available at the EPA website https://www.epa.gov/enviro/facility-registry-service-frs.

  13. Challenges for proteomics core facilities.

    PubMed

    Lilley, Kathryn S; Deery, Michael J; Gatto, Laurent

    2011-03-01

    Many analytical techniques have been executed by core facilities established within academic, pharmaceutical and other industrial institutions. The centralization of such facilities ensures a level of expertise and hardware which often cannot be supported by individual laboratories. The establishment of a core facility thus makes the technology available for multiple researchers in the same institution. Often, the services within the core facility are also opened out to researchers from other institutions, frequently with a fee being levied for the service provided. In the 1990s, with the onset of the age of genomics, there was an abundance of DNA analysis facilities, many of which have since disappeared from institutions and are now available through commercial sources. Ten years on, as proteomics was beginning to be utilized by many researchers, this technology found itself an ideal candidate for being placed within a core facility. We discuss what in our view are the daily challenges of proteomics core facilities. We also examine the potential unmet needs of the proteomics core facility that may also be applicable to proteomics laboratories which do not function as core facilities. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. VIEW OF BUILDING 122 EXAMINATION FACILITIES THAT SUPPORT ROUTINE EMPLOYEE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    VIEW OF BUILDING 122 EXAMINATION FACILITIES THAT SUPPORT ROUTINE EMPLOYEE AND SUBCONTRACTOR PHYSICAL EXAMINATIONS. (10/85) - Rocky Flats Plant, Emergency Medical Services Facility, Southwest corner of Central & Third Avenues, Golden, Jefferson County, CO

  15. EPA Facility Registry Service (FRS): CAMDBS

    EPA Pesticide Factsheets

    This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link to the Clean Air Markets Division Business System (CAMDBS). Administered by the EPA Clean Air Markets Division, within the Office of Air and Radiation, CAMDBS supports the implementation of market-based air pollution control programs, including the Acid Rain Program and regional programs designed to reduce the transport of ozone. FRS identifies and geospatially locates facilities, sites or places subject to environmental regulations or of environmental interest. Using vigorous verification and data management procedures, FRS integrates facility data from EPA's national program systems, other federal agencies, and State and tribal master facility records and provides EPA with a centrally managed, single source of comprehensive and authoritative information on facilities. This data set contains the subset of FRS integrated facilities that link to CAMDBS facilities once the CAMDBS data has been integrated into the FRS database. Additional information on FRS is available at the EPA website https://www.epa.gov/enviro/facility-registry-service-frs.

  16. EPA Facility Registry Service (FRS): RCRA

    EPA Pesticide Factsheets

    This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of hazardous waste facilities that link to the Resource Conservation and Recovery Act Information System (RCRAInfo). EPA's comprehensive information system in support of the Resource Conservation and Recovery Act (RCRA) of 1976 and the Hazardous and Solid Waste Amendments (HSWA) of 1984, RCRAInfo tracks many types of information about generators, transporters, treaters, storers, and disposers of hazardous waste. FRS identifies and geospatially locates facilities, sites or places subject to environmental regulations or of environmental interest. Using vigorous verification and data management procedures, FRS integrates facility data from EPA's national program systems, other federal agencies, and State and tribal master facility records and provides EPA with a centrally managed, single source of comprehensive and authoritative information on facilities. This data set contains the subset of FRS integrated facilities that link to RCRAInfo hazardous waste facilities once the RCRAInfo data has been integrated into the FRS database. Additional information on FRS is available at the EPA website https://www.epa.gov/enviro/facility-registry-service-frs

  17. EPA FRS Facilities Combined File CSV Download for the Marshall Islands

    EPA Pesticide Factsheets

    The Facility Registry System (FRS) identifies facilities, sites, or places subject to environmental regulation or of environmental interest to EPA programs or delegated states. Using vigorous verification and data management procedures, FRS integrates facility data from program national systems, state master facility records, tribal partners, and other federal agencies and provides the Agency with a centrally managed, single source of comprehensive and authoritative information on facilities.

  18. EPA FRS Facilities Single File CSV Download for the Marshall Islands

    EPA Pesticide Factsheets

    The Facility Registry System (FRS) identifies facilities, sites, or places subject to environmental regulation or of environmental interest to EPA programs or delegated states. Using vigorous verification and data management procedures, FRS integrates facility data from program national systems, state master facility records, tribal partners, and other federal agencies and provides the Agency with a centrally managed, single source of comprehensive and authoritative information on facilities.

  19. EPA Facility Registry System (FRS): NCES

    EPA Pesticide Factsheets

    This web feature service contains location and facility identification information from EPA's Facility Registry System (FRS) for the subset of facilities that link to the National Center for Education Statistics (NCES). The primary federal database for collecting and analyzing data related to education in the United States and other Nations, NCES is located in the U.S. Department of Education, within the Institute of Education Sciences. FRS identifies and geospatially locates facilities, sites or places subject to environmental regulations or of environmental interest. Using vigorous verification and data management procedures, FRS integrates facility data from EPA00e2??s national program systems, other federal agencies, and State and tribal master facility records and provides EPA with a centrally managed, single source of comprehensive and authoritative information on facilities. This data set contains the subset of FRS integrated facilities that link to NCES school facilities once the NCES data has been integrated into the FRS database. Additional information on FRS is available at the EPA website http://www.epa.gov/enviro/html/fii/index.html.

  20. Conceptualization and design of a variable-gravity research facility

    NASA Technical Reports Server (NTRS)

    1987-01-01

    The goal is to provide facilities for the study of the effects of variable-gravity levels in reducing the physiological stresses upon the humans of long-term stay time in zero-g. The designs studied include: twin-tethered two module system with a central despun module with docking port and winch gear; and rigid arm tube facility using shuttle external tanks. Topics examined included: despun central capsule configuration, docking clearances, EVA requirements, crew selection, crew scheduling, food supply and preparation, waste handling, leisure use, biomedical issues, and psycho-social issues.

  1. At the Cosmonaut Hotel in Baikonur, Kazakhstan, Expedition 48-49 backup crewmember Peggy Whitson of NASA waters a tree in her name first planted in 2007 during traditional pre-launch activities June 30. Whitson is one of three backups to the prime crewmembers, Kate Rubins of NASA, Anatoly Ivanishin of Roscosmos and Takuya Onishi of the Japan Aerospace Exploration Agency, who will launch July 7, Baikonur time, on the Soyuz MS-01 spacecraft for a planned four-month mission on the International Space Station...NASA/Alexander Vysotsky.

    NASA Image and Video Library

    2016-06-30

    At the Cosmonaut Hotel in Baikonur, Kazakhstan, Expedition 48-49 backup crewmember Peggy Whitson of NASA waters a tree in her name first planted in 2007 during traditional pre-launch activities June 30. Whitson is one of three backups to the prime crewmembers, Kate Rubins of NASA, Anatoly Ivanishin of Roscosmos and Takuya Onishi of the Japan Aerospace Exploration Agency, who will launch July 7, Baikonur time, on the Soyuz MS-01 spacecraft for a planned four-month mission on the International Space Station. NASA/Alexander Vysotsky

  2. EPA Facility Registry Service (FRS): TRI

    EPA Pesticide Factsheets

    This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link to the Toxic Release Inventory (TRI) System. TRI is a publicly available EPA database reported annually by certain covered industry groups, as well as federal facilities. It contains information about more than 650 toxic chemicals that are being used, manufactured, treated, transported, or released into the environment, and includes information about waste management and pollution prevention activities. FRS identifies and geospatially locates facilities, sites or places subject to environmental regulations or of environmental interest. Using vigorous verification and data management procedures, FRS integrates facility data from EPA's national program systems, other federal agencies, and State and tribal master facility records and provides EPA with a centrally managed, single source of comprehensive and authoritative information on facilities. This data set contains the subset of FRS integrated facilities that link to TRI facilities once the TRI data has been integrated into the FRS database. Additional information on FRS is available at the EPA website https://www.epa.gov/enviro/facility-registry-service-frs.

  3. 75 FR 30421 - Central Utah Project Completion Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-01

    ... facilities of the Wasatch County Water Efficiency Project (WCWEP), Bonneville Unit, Central Utah Project (CUP... conservation and wise use of water, all of which are objectives of the CUP Completion Act. The proposed action would allow recycled water to be conveyed and used in WCWEP facilities and through exchange become CUP...

  4. Centralization vs. Decentralization: A Location Analysis Approach for Librarians

    ERIC Educational Resources Information Center

    Raffel, Jeffrey; Shishko, Robert

    1972-01-01

    An application of location theory to the question of centralized versus decentralized library facilities for a university, with relevance for special libraries is presented. The analysis provides models for a single library, for two or more libraries, or for decentralized facilities. (6 references) (Author/NH)

  5. Alternative end-joining repair pathways are the ultimate backup for abrogated classical non-homologous end-joining and homologous recombination repair: Implications for the formation of chromosome translocations.

    PubMed

    Iliakis, George; Murmann, Tamara; Soni, Aashish

    2015-11-01

    DNA double strand breaks (DSB) are the most deleterious lesions for the integrity of the genome, as their misrepair can lead to the formation of chromosome translocations. Cells have evolved two main repair pathways to suppress the formation of these genotoxic lesions: homology-dependent, error-free homologous recombination repair (HRR), and potentially error-prone, classical, DNA-PK-dependent non-homologous end-joining (c-NHEJ). The most salient feature of c-NHEJ, speed, will largely suppress chromosome translocation formation, while sequence alterations at the junction remain possible. It is now widely accepted that when c-NHEJ is inactivated, globally or locally, an alternative form of end-joining (alt-EJ) removes DSBs. Alt-EJ operates with speed and fidelity markedly lower than c-NHEJ, causing thus with higher probability chromosome translocations, and generating more extensive sequence alterations at the junction. Our working hypothesis is that alt-EJ operates as a backup to c-NHEJ. Recent results show that alt-EJ can also backup abrogated HRR in G2 phase cells, again at the cost of elevated formation of chromosome translocations. These observations raise alt-EJ to a global rescuing mechanism operating on ends that have lost their chromatin context in ways that compromise processing by HRR or c-NHEJ. While responsible for eliminating from the genome highly cytotoxic DNA ends, alt-EJ provides this function at the price of increased translocation formation. Here, we analyze recent literature on the mechanisms of chromosome translocation formation and propose a functional hierarchy among DSB processing pathways that makes alt-EJ the global backup pathway. We discuss possible ramifications of this model in cellular DSB management and pathway choice, and analyze its implications in radiation carcinogenesis and the design of novel therapeutic approaches. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Coordination and establishment of centralized facilities and services of the University of Alaska ERTS survey of the Alaskan environment

    NASA Technical Reports Server (NTRS)

    Belon, A. E. (Principal Investigator); Miller, J. M.

    1973-01-01

    The author has identified the following significant results. The objective of this project is to provide a focus for the entire University of Alaska ERTS-1 effort (12 projects covering 10 disciplines and involving 8 research institutes and science departments). Activities have been concentrated on the implementation of the project's three primary functions: (1) coordination and management of the U of A ERTS-1 program, including management of the flow of data and data products; (2) acquisition, installation, test, operation, and maintanence of centralized facilities for processing ERTS-1, aircraft, and ground truth data; and (3) development of photographic and digital techniques for processing and interpreting ERTS-1 and aircraft data. With minor exceptions these three functions are now well-established and working smoothly.

  7. Disaster recovery plan for HANDI 2000 business management system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Adams, D.E.

    The BMS production implementation will be complete by October 1, 1998 and the server environment will be comprised of two types of platforms. The PassPort Supply and the PeopleSoft Financials will reside on LNIX servers and the PeopleSoft Human Resources and Payroll will reside on Microsoft NT servers. Because of the wide scope and the requirements of the COTS products to run in various environments backup and recovery responsibilities are divided between two groups in Technical Operations. The Central Computer Systems Management group provides support for the LTNIX/NT Backup Data Center, and the Network Infrastructure Systems group provides support formore » the NT Application Server Backup outside the Data Center. The disaster recovery process is dependent on a good backup and recovery process. Information and integrated system data for determining the disaster recovery process is identified from the Fluor Daniel Hanford (FDH) Risk Assessment Plan, Contingency Plan, and Backup and Recovery Plan, and Backup Form for HANDI 2000 BMS.« less

  8. Central Plateau Cleanup at DOE's Hanford Site - 12504

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dowell, Jonathan

    The discussion of Hanford's Central Plateau includes significant work in and around the center of the Hanford Site - located about 7 miles from the Columbia River. The Central Plateau is the area to which operations will be shrunk in 2015 when River Corridor cleanup is complete. This work includes retrieval and disposal of buried waste from miles of trenches; the cleanup and closure of massive processing canyons; the clean-out and demolition to 'slab on grade' of the high-hazard Plutonium Finishing Plant; installation of key groundwater treatment facilities to contain and shrink plumes of contaminated groundwater; demolition of all othermore » unneeded facilities; and the completion of decisions about remaining Central Plateau waste sites. A stated goal of EM has been to shrink the footprint of active cleanup to less than 10 square miles by 2020. By the end of FY2011, Hanford will have reduced the active footprint of cleanup by 64 percent exceeding the goal of 49 percent. By 2015, Hanford will reduce the active footprint of cleanup by more than 90 percent. The remaining footprint reduction will occur between 2015 and 2020. The Central Plateau is a 75-square-mile region near the center of the Hanford Site including the area designated in the Hanford Comprehensive Land Use Plan Environmental Impact Statement (DOE 1999) and Record of Decision (64 FR 61615) as the Industrial-Exclusive Area, a rectangular area of about 20 square miles in the center of the Central Plateau. The Industrial-Exclusive Area contains the 200 East and 200 West Areas that have been used primarily for Hanford's nuclear fuel processing and waste management and disposal activities. The Central Plateau also encompasses the 200 Area CERCLA National Priorities List site. The Central Plateau has a large physical inventory of chemical processing and support facilities, tank systems, liquid and solid waste disposal and storage facilities, utility systems, administrative facilities, and groundwater

  9. The emergence of care facilities in Thailand for older German-speaking people: structural backgrounds and facility operators as transnational actors.

    PubMed

    Bender, Désirée; Hollstein, Tina; Schweppe, Cornelia

    2017-12-01

    This paper presents findings from an ethnographic study of old age care facilities for German-speaking people in Thailand. It analyses the conditions and processes behind the development and specific designs of such facilities. It first looks at the intertwinement, at the socio-structural level, of different transborder developments in which the facilities' emergence is embedded. Second, it analyses the processes that accompany the emergence, development and organisation of these facilities at the local level. In this regard, it points out the central role of the facility operators as transnational actors who mediate between different frames of reference and groups of actors involved in these facilities. It concludes that the processes of mediation and intertwining are an important and distinctive feature of the emergence of these facilities, necessitated by the fact that, although the facilities are located in Thailand, their 'markets' are in the German-speaking countries of their target groups.

  10. Earth Observatory Satellite system definition study. Report 5: System design and specifications. Volume 6: Specification for EOS Central Data Processing Facility (CDPF)

    NASA Technical Reports Server (NTRS)

    1974-01-01

    The specifications and functions of the Central Data Processing (CDPF) Facility which supports the Earth Observatory Satellite (EOS) are discussed. The CDPF will receive the EOS sensor data and spacecraft data through the Spaceflight Tracking and Data Network (STDN) and the Operations Control Center (OCC). The CDPF will process the data and produce high density digital tapes, computer compatible tapes, film and paper print images, and other data products. The specific aspects of data inputs and data processing are identified. A block diagram of the CDPF to show the data flow and interfaces of the subsystems is provided.

  11. Glutathione and Glutaredoxin Act as a Backup of Human Thioredoxin Reductase 1 to Reduce Thioredoxin 1 Preventing Cell Death by Aurothioglucose*

    PubMed Central

    Du, Yatao; Zhang, Huihui; Lu, Jun; Holmgren, Arne

    2012-01-01

    Thioredoxin reductase 1 (TrxR1) in cytosol is the only known reductant of oxidized thioredoxin 1 (Trx1) in vivo so far. We and others found that aurothioglucose (ATG), a well known active-site inhibitor of TrxR1, inhibited TrxR1 activity in HeLa cell cytosol but had no effect on the viability of the cells. Using a redox Western blot analysis, no change was observed in redox state of Trx1, which was mainly fully reduced with five sulfhydryl groups. In contrast, auranofin killed cells and oxidized Trx1, also targeting mitochondrial TrxR2 and Trx2. Combining ATG with ebselen gave a strong synergistic effect, leading to Trx1 oxidation, reactive oxygen species accumulation, and cell death. We hypothesized that there should exist a backup system to reduce Trx1 when only TrxR1 activity was lost. Our results showed that physiological concentrations of glutathione, NADPH, and glutathione reductase reduced Trx1 in vitro and that the reaction was strongly stimulated by glutaredoxin1. Simultaneous depletion of TrxR activity by ATG and glutathione by buthionine sulfoximine led to overoxidation of Trx1 and loss of HeLa cell viability. In conclusion, the glutaredoxin system and glutathione have a backup role to keep Trx1 reduced in cells with loss of TrxR1 activity. Monitoring the redox state of Trx1 shows that cell death occurs when Trx1 is oxidized, followed by general protein oxidation catalyzed by the disulfide form of thioredoxin. PMID:22977247

  12. Centralization Versus Decentralization: A Location Analysis Approach for Librarians.

    ERIC Educational Resources Information Center

    Shishko, Robert; Raffel, Jeffrey

    One of the questions that seems to perplex many university and special librarians is whether to move in the direction of centralizing or decentralizing the library's collections and facilities. Presented is a theoretical approach, employing location theory, to the library centralization-decentralization question. Location theory allows the analyst…

  13. Flight evaluation of a hydromechanical backup control for the digital electronic engine control system in an F100 engine

    NASA Technical Reports Server (NTRS)

    Walsh, K. R.; Burcham, F. W.

    1984-01-01

    The backup control (BUC) features, the operation of the BUC system, the BUC control logic, and the BUC flight test results are described. The flight test results include: (1) transfers to the BUC at military and maximum power settings; (2) a military power acceleration showing comparisons bvetween flight and simulation for BUC and primary modes; (3) steady-state idle power showing idle compressor speeds at different flight conditions; and (4) idle-to-military power BUC transients showing where cpmpressor stalls occurred for different ramp rates and idle speeds. All the BUC transfers which occur during the DEEC flight program are initiated by the pilot. Automatic transfers to the BUC do not occur.

  14. 32 CFR 1906.150 - Program accessibility: Existing facilities.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... INTELLIGENCE AGENCY ENFORCEMENT OF NONDISCRIMINATION ON THE BASIS OF HANDICAP IN PROGRAMS OR ACTIVITIES CONDUCTED BY THE CENTRAL INTELLIGENCE AGENCY § 1906.150 Program accessibility: Existing facilities. (a...

  15. 32 CFR 1906.150 - Program accessibility: Existing facilities.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... INTELLIGENCE AGENCY ENFORCEMENT OF NONDISCRIMINATION ON THE BASIS OF HANDICAP IN PROGRAMS OR ACTIVITIES CONDUCTED BY THE CENTRAL INTELLIGENCE AGENCY § 1906.150 Program accessibility: Existing facilities. (a...

  16. 32 CFR 1906.150 - Program accessibility: Existing facilities.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... INTELLIGENCE AGENCY ENFORCEMENT OF NONDISCRIMINATION ON THE BASIS OF HANDICAP IN PROGRAMS OR ACTIVITIES CONDUCTED BY THE CENTRAL INTELLIGENCE AGENCY § 1906.150 Program accessibility: Existing facilities. (a...

  17. 32 CFR 1906.150 - Program accessibility: Existing facilities.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... INTELLIGENCE AGENCY ENFORCEMENT OF NONDISCRIMINATION ON THE BASIS OF HANDICAP IN PROGRAMS OR ACTIVITIES CONDUCTED BY THE CENTRAL INTELLIGENCE AGENCY § 1906.150 Program accessibility: Existing facilities. (a...

  18. 32 CFR 1906.150 - Program accessibility: Existing facilities.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... INTELLIGENCE AGENCY ENFORCEMENT OF NONDISCRIMINATION ON THE BASIS OF HANDICAP IN PROGRAMS OR ACTIVITIES CONDUCTED BY THE CENTRAL INTELLIGENCE AGENCY § 1906.150 Program accessibility: Existing facilities. (a...

  19. Benzene contamination at a metal plating facility

    NASA Astrophysics Data System (ADS)

    Memon, B. A.; Burston, M. R.

    2005-08-01

    A metal plating facility in central Kentucky was required to complete a RCRA Facility Investigation to address a number of Solid Waste Management Units at the site. Twenty monitoring wells were installed at the facility. Ground water from the wells was sampled for total and dissolved metals, polychlorinated biphenyls, acid extractable compounds, base neutral compounds, and volatile organic compounds. Unexpectedly, relatively large concentrations of benzene, up to 120 μg/l, were detected in samples from some of the wells, including wells that should have been hydraulically upgradient from the facility. As a result of the detection of benzene, the facility completed an investigation to identify the source. A nearby facility had completed a gasoline underground storage tank (UST) closure at about the time of the installation of the 20 wells. Reportedly the UST had small holes when removed. Three potential pathways of migration (a ditch, sanitary sewer, and a sink hole) from the nearby facility to the metal-plating facility and residual soils with very large concentrations of benzene, toluene, ethylbenzene, and xylenes have been identified.

  20. Public acceptance for centralized storage and repositories of low-level waste session (Panel)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lutz, H.R.

    1995-12-31

    Participants from various parts of the world will provide a summary of their particular country`s approach to low-level waste management and the cost of public acceptance for low-level waste management facilities. Participants will discuss the number, geographic location, and type of low-level waste repositories and centralized storage facilities located in their countries. Each will discuss the amount, distribution, and duration of funds to gain public acceptance of these facilities. Participants will provide an estimated $/meter for centralized storage facilities and repositories. The panel will include a brief discussion about the ethical aspects of public acceptance costs, approaches for negotiating acceptance,more » and lessons learned in each country. The audience is invited to participate in the discussion.« less

  1. Space transportation node - The Atrium Facility

    NASA Technical Reports Server (NTRS)

    Kennedy, Kriss J.

    1990-01-01

    A conceptual design for a space transportation node is presented with a view to the fulfilment of assembly platform support requirements associated with a lunar transportation system. This 'Atrium Facility', which will support lunar base activities before, during, and after the lunar base buildup phase, encompasses a central assembly area surrounded by hangars and workstation platforms; six permanent crewmembers will be supported, as well as four to six transient lunar and Space Shuttle crewmembers. The Atrium Facility dry mass of nearly 320,000 kg excludes cryogenic propellant stowage and the traslunar vehicle envisioned for transportation.

  2. EPA Facility Registry Service (FRS): ICIS

    EPA Pesticide Factsheets

    This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link to the Integrated Compliance Information System (ICIS). When complete, ICIS will provide a database that will contain integrated enforcement and compliance information across most of EPA's programs. The vision for ICIS is to replace EPA's independent databases that contain enforcement data with a single repository for that information. Currently, ICIS contains all Federal Administrative and Judicial enforcement actions and a subset of the Permit Compliance System (PCS), which supports the National Pollutant Discharge Elimination System (NPDES). ICIS exchanges non-sensitive enforcement/compliance activities, non-sensitive formal enforcement actions and NPDES information with FRS. This web feature service contains the enforcement/compliance activities and formal enforcement action related facilities; the NPDES facilities are contained in the PCS_NPDES web feature service. FRS identifies and geospatially locates facilities, sites or places subject to environmental regulations or of environmental interest. Using vigorous verification and data management procedures, FRS integrates facility data from EPA's national program systems, other federal agencies, and State and tribal master facility records and provides EPA with a centrally managed, single source of comprehensive and authoritative information on f

  3. A Novel Wide-Area Backup Protection Based on Fault Component Current Distribution and Improved Evidence Theory

    PubMed Central

    Zhang, Zhe; Kong, Xiangping; Yin, Xianggen; Yang, Zengli; Wang, Lijun

    2014-01-01

    In order to solve the problems of the existing wide-area backup protection (WABP) algorithms, the paper proposes a novel WABP algorithm based on the distribution characteristics of fault component current and improved Dempster/Shafer (D-S) evidence theory. When a fault occurs, slave substations transmit to master station the amplitudes of fault component currents of transmission lines which are the closest to fault element. Then master substation identifies suspicious faulty lines according to the distribution characteristics of fault component current. After that, the master substation will identify the actual faulty line with improved D-S evidence theory based on the action states of traditional protections and direction components of these suspicious faulty lines. The simulation examples based on IEEE 10-generator-39-bus system show that the proposed WABP algorithm has an excellent performance. The algorithm has low requirement of sampling synchronization, small wide-area communication flow, and high fault tolerance. PMID:25050399

  4. Central Libraries in Uncertain Times.

    ERIC Educational Resources Information Center

    Kenney, Brian J.

    2001-01-01

    Discusses security and safety issues for public libraries, especially high-profile central facilities, in light of the September 11 terrorist attacks. Highlights include inspecting bags as patrons enter as well as exit; the need for security guidelines for any type of disaster or emergency; building design; and the importance of communication.…

  5. Feasibility of a small central cogenerated energy facility: Energy management memorandum

    NASA Astrophysics Data System (ADS)

    Porter, R. N.

    1982-10-01

    The thermal economic feasibility of a small cogenerated energy facility designed to serve several industries in the Stockyards area was investigated. Cogeneration options included two dual fuel diesels and two gas turbines, all with waste heat boilers, and five fired boilers. Fuels included natural gas, and for the fired boiler cases, also low sulphur coal and municipal refuse. For coal and refuse, the option of steam only without cogeneration was also assessed. The fired boiler cogeneration systems employed back pressure steam turbines. The refuse fired cases utilized electrical capacities, 8500 to 52,400 lbm/hr and 0 to 9.9 MW (e), respectively. Deficient steam was assumed generated independently in existing equipment. Excess electrical power over that which was displaced was sold to Commonwealth Edison Company under PURPA (Public Utility Regulatory Policies Act). The facility was operated by a mutually owned corporation formed by the cogenerated power users.

  6. Fuel Storage Tanks at FAA Facilities: Order 1050.15A

    DOT National Transportation Integrated Search

    1997-04-30

    The Federal Aviation Administration (FAA) has over 4,000 fuel storage tanks (FST) in its : inventory. Most of these FSTs are underground storage tanks (UST) that contain fuel for : emergency backup generators providing secondary power to air navigati...

  7. Microscale air quality impacts of distributed power generation facilities.

    PubMed

    Olaguer, Eduardo P; Knipping, Eladio; Shaw, Stephanie; Ravindran, Satish

    2016-08-01

    The electric system is experiencing rapid growth in the adoption of a mix of distributed renewable and fossil fuel sources, along with increasing amounts of off-grid generation. New operational regimes may have unforeseen consequences for air quality. A three-dimensional microscale chemical transport model (CTM) driven by an urban wind model was used to assess gaseous air pollutant and particulate matter (PM) impacts within ~10 km of fossil-fueled distributed power generation (DG) facilities during the early afternoon of a typical summer day in Houston, TX. Three types of DG scenarios were considered in the presence of motor vehicle emissions and a realistic urban canopy: (1) a 25-MW natural gas turbine operating at steady state in either simple cycle or combined heating and power (CHP) mode; (2) a 25-MW simple cycle gas turbine undergoing a cold startup with either moderate or enhanced formaldehyde emissions; and (3) a data center generating 10 MW of emergency power with either diesel or natural gas-fired backup generators (BUGs) without pollution controls. Simulations of criteria pollutants (NO2, CO, O3, PM) and the toxic pollutant, formaldehyde (HCHO), were conducted assuming a 2-hr operational time period. In all cases, NOx titration dominated ozone production near the source. The turbine scenarios did not result in ambient concentration enhancements significantly exceeding 1 ppbv for gaseous pollutants or over 1 µg/m(3) for PM after 2 hr of emission, assuming realistic plume rise. In the case of the datacenter with diesel BUGs, ambient NO2 concentrations were enhanced by 10-50 ppbv within 2 km downwind of the source, while maximum PM impacts in the immediate vicinity of the datacenter were less than 5 µg/m(3). Plausible scenarios of distributed fossil generation consistent with the electricity grid's transformation to a more flexible and modernized system suggest that a substantial amount of deployment would be required to significantly affect air quality on

  8. Composite analysis E-area vaults and saltstone disposal facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cook, J.R.

    1997-09-01

    This report documents the Composite Analysis (CA) performed on the two active Savannah River Site (SRS) low-level radioactive waste (LLW) disposal facilities. The facilities are the Z-Area Saltstone Disposal Facility and the E-Area Vaults (EAV) Disposal Facility. The analysis calculated potential releases to the environment from all sources of residual radioactive material expected to remain in the General Separations Area (GSA). The GSA is the central part of SRS and contains all of the waste disposal facilities, chemical separations facilities and associated high-level waste storage facilities as well as numerous other sources of radioactive material. The analysis considered 114 potentialmore » sources of radioactive material containing 115 radionuclides. The results of the CA clearly indicate that continued disposal of low-level waste in the saltstone and EAV facilities, consistent with their respective radiological performance assessments, will have no adverse impact on future members of the public.« less

  9. Independent Orbiter Assessment (IOA): Assessment of the backup flight system FMEA/CIL

    NASA Technical Reports Server (NTRS)

    Prust, E. E.; Ewell, J. J., Jr.; Hinsdale, L. W.

    1988-01-01

    The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA effort first completed an analysis of the Backup Flight System (BFS) hardware, generating draft failure modes and Potential Critical Items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The IOA results were then compared to the proposed NASA Post 51-L FMEA/CIL baseline. A resolution of each discrepancy from the comparison is provided through additional analysis as required. This report documents the results of that comparison for the Orbiter BFS hardware. The IOA product for the BFS analysis consisted of 29 failure mode worksheets that resulted in 21 Potential Critical Items (PCI) being identified. This product was originally compared with the proposed NASA BFS baseline and subsequently compared with the applicable Data Processing System (DPS), Electrical Power Distribution and Control (EPD and C), and Displays and Controls NASA CIL items. The comparisons determined if there were any results which had been found by the IOA but were not in the NASA baseline. The original assessment determined there were numerous failure modes and potential critical items in the IOA analysis that were not contained in the NASA BFS baseline. Conversely, the NASA baseline contained three FMEAs (IMU, ADTA, and Air Data Probe) for CIL items that were not identified in the IOA product.

  10. Public water supplies in central and north-central Texas

    USGS Publications Warehouse

    Sundstrom, Raymond W.; Broadhurst, W.L.; Dwyer, B.C.

    1949-01-01

    This report gives a summarized description of the public water supplies in 35 counties of central and north-central Texas, extending from the southern boundaries of Travis, Blanco, Gillespie, and Kerr Counties northward to the TexasOklahoma State line. It gives the available data as follows for each of the 145 communities: Population of the community; name of the official from whom the information was obtained; ownership of water works, whether private or municipal source of supply, whether ground water or surface water; the amount of water consumed; the facilities for storage; the number of customers served; the character of the chemical and sanitary treatment, if any; and chemical analyses of the water. Where ground water is used, the following is also given: Records of wells, including drillers' logs; character of the pumping equipment; yields of the wells, and records of water levels, if available.

  11. Trauma facilities in Denmark - a nationwide cross-sectional benchmark study of facilities and trauma care organisation.

    PubMed

    Weile, Jesper; Nielsen, Klaus; Primdahl, Stine C; Frederiksen, Christian A; Laursen, Christian B; Sloth, Erik; Mølgaard, Ole; Knudsen, Lars; Kirkegaard, Hans

    2018-03-27

    Trauma is a leading cause of death among adults aged < 44 years, and optimal care is a challenge. Evidence supports the centralization of trauma facilities and the use multidisciplinary trauma teams. Because knowledge is sparse on the existing distribution of trauma facilities and the organisation of trauma care in Denmark, the aim of this study was to identify all Danish facilities that care for traumatized patients and to investigate the diversity in organization of trauma management. We conducted a systematic observational cross-sectional study. First, all hospitals in Denmark were identified via online services and clarifying phone calls to each facility. Second, all trauma care manuals on all facilities that receive traumatized patients were gathered. Third, anesthesiologists and orthopedic surgeons on call at all trauma facilities were contacted via telephone for structured interviews. A total of 22 facilities in Denmark were found to receive traumatized patients. All facilities used a trauma care manual and all had a multidisciplinary trauma team. The study found three different trauma team activation criteria and nine different compositions of teams who participate in trauma care. Training was heterogeneous and, beyond the major trauma centers, databases were only maintained in a few facilities. The study established an inventory of the existing Danish facilities that receive traumatized patients. The trauma team activation criteria and the trauma teams were heterogeneous in both size and composition. A national database for traumatized patients, research on nationwide trauma team activation criteria, and team composition guidelines are all called for.

  12. Telemedicine in general neurology: use of audiovisual consultation for on call back-up service in an acute care hospital.

    PubMed

    Janssen, Frank; Awadallah, Mohammed; Alhalabi, Awed; Körber, Barbara; Lang, Reinhard; Scibor, Mateusz; Handschu, René

    2018-04-01

    While telemedicine is in expanding use in acute stroke care, little is known about its use in general neurology, especially in acute care. We sought to investigate the feasibility and possible effects of a telemedicine device within the neurological back-up service of an acute care hospital. In a 450 bed academic teaching hospital an experienced neurologist (EN) is on call to support the junior doctor at the hospital. Support was possible whether by standard telephone advice (TA) or by audiovisual consultations (AVC). In AVC the expert used a mobile telemedicine device and so he could establish audiovisual contact from his home to the emergency room and examine newly admitted patients. Technical and patient details including timing and diagnosis were recorded. Video and audio quality as well as impact of AVC on diagnosis was rated by the EN. Out of about 1200 cases in off peak times, during the study period, 164 AVC including remote video examination were done (13.6%). Also 48 cases were documented by pure TA. Video quality was rated to a medium of 1.7, audio quality to 2.1. In 36 cases the audiovisual consultation was influenced by technical issues leading to cessation of AVC in 8 cases. Duration of teleconsultation was 17.3 min in AVC compared to 8.7 min for TA. The consultation diagnosis in AVC was confirmed in 74.4% of all cases compared to 57.7% in TA. AVC was rated as a valuable contribution to the diagnostic workup in 74.3% of all cases seen. In about 40% of all cases AVC was not possible due to technical or organizational reasons. Audiovisual consultation seems to be a feasible and useful support in routine neurology back-up service of an acute care hospital. Better mobility of devices and flexibility of service is needed to improve availability and quality of this valuable tool.

  13. Measuring School Facility Conditions: An Illustration of the Importance of Purpose

    ERIC Educational Resources Information Center

    Roberts, Lance W.

    2009-01-01

    Purpose: The purpose of this paper is to argue that taking the educational purposes of schools into account is central to understanding the place and importance of facilities to learning outcomes. The paper begins by observing that the research literature connecting facility conditions to student outcomes is mixed. A closer examination of this…

  14. EPA Facility Registry Service (FRS): PCS_NPDES

    EPA Pesticide Factsheets

    This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link to the Permit Compliance System (PCS) or the National Pollutant Discharge Elimination System (NPDES) module of the Integrated Compliance Information System (ICIS). PCS tracks NPDES surface water permits issued under the Clean Water Act. This system is being incrementally replaced by the NPDES module of ICIS. Under NPDES, all facilities that discharge pollutants from any point source into waters of the United States are required to obtain a permit. The permit will likely contain limits on what can be discharged, impose monitoring and reporting requirements, and include other provisions to ensure that the discharge does not adversely affect water quality. FRS identifies and geospatially locates facilities, sites or places subject to environmental regulations or of environmental interest. Using vigorous verification and data management procedures, FRS integrates facility data from EPA's national program systems, other federal agencies, and State and tribal master facility records and provides EPA with a centrally managed, single source of comprehensive and authoritative information on facilities. This data set contains the subset of FRS integrated facilities that link to NPDES facilities once the PCS or ICIS-NPDES data has been integrated into the FRS database. Additional information on FRS is available

  15. View looking SE inside Electrical Shop Central of Georgia ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    View looking SE inside Electrical Shop - Central of Georgia Railway, Savannah Repair Shops & Terminal Facilities, Electrical Shop, Bounded by West Broad, Jones, West Boundary & Hull Streets, Savannah, Chatham County, GA

  16. 9. Smoke flue coming through Roundhouse roof. Central of ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    9. Smoke flue coming through Roundhouse roof. - Central of Georgia Railway, Savannah Repair Shops & Terminal Facilities, Roundhouse, Site Bounded by West Broad, Jones, West Boundary & Hull, Savannah, Chatham County, GA

  17. The utilization of intravenous therapy programs in community long-term care nursing facilities.

    PubMed

    Weinberg, A D; Pals, J K; Wei, J Y

    1997-01-01

    To determine if non-federal Boston-area long-term care nursing facilities are actively using intravenous (IV) therapy as a form of treatment, the specific design of such programs and to assess the availability of central line IVs, percutaneous endoscopic gastrostomy (PEG) tubes and hypodermoclysis for hydration in this setting. DESIGN/SETTINGS: A prospective telephone survey of 100 Boston-area skilled nursing facilities, each with a minimum of 50 beds and representing a total of 12,763 beds, certified to provide both Medicaid (Title-19) and Medicare services, to ascertain their ability to provide IV and other modes of hydration for their residents. A series of questions were asked of a member of the staff knowledgeable in the operations of the nursing facility. Questions included whether an IV program was in existence, duration of the program, provider of IV training for nurses, presence of a subacute unit, whether IVs were administered in non-subacute areas, frequency of IV usage, the ability to manage central lines and the use of PEG tubes or hypodermoclysis for hydration. A total of 100 nursing facilities were surveyed between September and October of 1996. A total of 79 nursing facilities had active IV programs (79%) and 54 of those (68%) also managed central lines. However, in those facilities with active IV programs, 73% (N = 58) reported administering a total of less than five IVs per month. Training for 82% of the nursing facilities (N = 65) was by an outside vendor pharmacy and initial training ranged from one to three days in duration. Of the 19 nursing facilities with IV programs available only in subacute or equivalent units, only 26% (N = 5) did not allow direct transfer of residents from other wards into these units. Of the 79 nursing facilities having IV capability, a total of 91% (N = 72) have also used PEG tubes for hydration and nutritional needs although only 6% (N = 5) have ever used hypodermoclysis for hydration. The majority of nursing

  18. National Biomedical Tracer Facility. Project definition study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schafer, R.

    We request a $25 million government-guaranteed, interest-free loan to be repaid over a 30-year period for construction and initial operations of a cyclotron-based National Biomedical Tracer Facility (NBTF) in North Central Texas. The NBTF will be co-located with a linear accelerator-based commercial radioisotope production facility, funded by the private sector at approximately $28 million. In addition, research radioisotope production by the NBTF will be coordinated through an association with an existing U.S. nuclear reactor center that will produce research and commercial radioisotopes through neutron reactions. The combined facilities will provide the full range of technology for radioisotope production and research:more » fast neutrons, thermal neutrons, and particle beams (H{sup -}, H{sup +}, and D{sup +}). The proposed NBTF facility includes an 80 MeV, 1 mA H{sup -} cyclotron that will produce proton-induced (neutron deficient) research isotopes.« less

  19. VIEW OF BUILDING 122 WHICH HOUSES THE ONSITE MEDICAL FACILITIES ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    VIEW OF BUILDING 122 WHICH HOUSES THE ON-SITE MEDICAL FACILITIES OF THE ROCKY FLATS PLANT AND THE OCCUPATIONAL HEALTH AND INTERNAL DOSIMETRY ORGANIZATIONS. EMERGENCY MEDICAL SERVICES, DIAGNOSIS, DECONTAMINATION, FIRST AID, X-RAY, MINOR SURGICAL TREATMENT, AND AMBULATORY ACTIVITIES ARE CARRIED OUT IN THIS BUILDING. (1/98) - Rocky Flats Plant, Emergency Medical Services Facility, Southwest corner of Central & Third Avenues, Golden, Jefferson County, CO

  20. The Hydrologic Instrumentation Facility of the U.S. Geological Survey

    USGS Publications Warehouse

    Wagner, C.R.; Jeffers, Sharon

    1984-01-01

    The U.S. Geological Survey Water Resources Division has improved support to the agencies field offices by the consolidation of all instrumentation support services in a single facility. This facility known as the Hydrologic Instrumentation Facility (HIF) is located at the National Space Technology Laboratory, Mississippi, about 50 miles east of New Orleans, Louisiana. The HIF is responsible for design and development, testing, evaluation, procurement, warehousing, distribution and repair of a variety of specialized hydrologic instrumentation. The centralization has resulted in more efficient and effective support of the Survey 's hydrologic programs. (USGS)

  1. Central Dental Evacuation Systems.

    DTIC Science & Technology

    1982-05-01

    handpiece . Inlets to this system are required throughout the dental facility for all disciplines of patient treatment where coolant and irrigation liquids...speed air turbine dental handpiece is used and for practically all other procedures in the practice of modern dentistry. Performance and reliability...AD-AI16 653 SCHOOL OF AEROSPACE MEDICINE BROOKS AFR TX F/G 6/5 CENTRAL DENTAL EVACUATION SYSTEMS.(U) MAY 52 J M POWELL, J M YOUNG UNCLASSIFIED SAM-TR

  2. The Cost-Optimal Distribution of Wind and Solar Generation Facilities in a Simplified Highly Renewable European Power System

    NASA Astrophysics Data System (ADS)

    Kies, Alexander; von Bremen, Lüder; Schyska, Bruno; Chattopadhyay, Kabitri; Lorenz, Elke; Heinemann, Detlev

    2016-04-01

    The transition of the European power system from fossil generation towards renewable sources is driven by different reasons like decarbonisation and sustainability. Renewable power sources like wind and solar have, due to their weather dependency, fluctuating feed-in profiles, which make their system integration a difficult task. To overcome this issue, several solutions have been investigated in the past like the optimal mix of wind and PV [1], the extension of the transmission grid or storages [2]. In this work, the optimal distribution of wind turbines and solar modules in Europe is investigated. For this purpose, feed-in data with an hourly temporal resolution and a spatial resolution of 7 km covering Europe for the renewable sources wind, photovoltaics and hydro was used. Together with historical load data and a transmission model , a simplified pan-European power power system was simulated. Under cost assumptions of [3] the levelized cost of electricity (LCOE) for this simplified system consisting of generation, consumption, transmission and backup units is calculated. With respect to the LCOE, the optimal distribution of generation facilities in Europe is derived. It is shown, that by optimal placement of renewable generation facilities the LCOE can be reduced by more than 10% compared to a meta study scenario [4] and a self-sufficient scenario (every country produces on average as much from renewable sources as it consumes). This is mainly caused by a shift of generation facilities towards highly suitable locations, reduced backup and increased transmission need. The results of the optimization will be shown and implications for the extension of renewable shares in the European power mix will be discussed. The work is part of the RESTORE 2050 project (Wuppertal Institute, Next Energy, University of Oldenburg), that is financed by the Federal Ministry of Education and Research (BMBF, Fkz. 03SFF0439A). [1] Kies, A. et al.: Kies, Alexander, et al

  3. jsc2017e136057 - On a snowy night at Red Square Moscow, Expedition 54-55 backup crewmembers Sergey Prokopyev of the Russian Federal Space Agency (Roscosmos, left), Jeanette Epps of NASA (center) and Alexander Gerst of the European Space Agency (right) pay

    NASA Image and Video Library

    2017-11-30

    jsc2017e136057 - On a snowy night at Red Square Moscow, Expedition 54-55 backup crewmembers Sergey Prokopyev of the Russian Federal Space Agency (Roscosmos, left), Jeanette Epps of NASA (center) and Alexander Gerst of the European Space Agency (right) pay homage at the Kremlin Wall where Russian space icons are interred in traditional pre-launch ceremonies Nov. 30. They are backups to Anton Shkaplerov of Roscosmos, Scott Tingle of NASA and Norishige Kanai of the Japan Aerospace Exploration Agency (JAXA), who will launch from the Baikonur Cosmodrome in Kazakhstan on the Soyuz MS-07 spacecraft Dec. 17 for a five-month mission on the International Space Station...Andrey Shelepin/Gagarin Cosmonaut Training Center.

  4. The backup is active in Alzheimer's disease: a hypothesis from problem theory.

    PubMed

    Burnand, Gordon

    2015-03-01

    Problem theory distinguishes between six general problems of everyday life, which people work through in turn during childhood, learning to switch between them. One of them requires the protection of a cut-out and an override. People who develop Alzheimer's disease (AD), and apolipoprotein allele epsilon 4 carriers, are preoccupied with this problem, or readily switch back to it. It is the freedom problem, of raising hope or confidence of freedom or power to control. Here people try to raise hope of success with any task on which attention happens to rest. This indiscriminateness means that there is no basis for giving up on a task, or for avoiding dangerous environments. Thus the cut-out is needed when someone becomes stuck on a mental task and the override is needed so as to help in avoiding danger. Activity relevant to the freedom problem is confined to the left hemisphere and the right hemisphere operates the cut-out and override. In providing these two forms of protection the right hemisphere can be said to act as a backup. Accordingly EEG, metabolism, and atrophy findings indicate that both cut-out and override are active in mild clinical impairment, especially among patients who later develop AD. The pattern of atrophy of AD matches what would be expected from disuse caused by an overactive cut-out followed by an overactive override. A parallel loss of testosterone might contribute to the weakening of resistance to infections leading to autoimmune effects. Copyright © 2015 The Author. Published by Elsevier Ltd.. All rights reserved.

  5. KENNEDY SPACE CENTER, FLA. - NASA Administrator Sean O’Keefe (center) is welcomed to the Central Florida Research Park, near Orlando. Central Florida leaders are proposing the research park as the site for the new NASA Shared Services Center. The center would centralize NASA’s payroll, accounting, human resources, facilities and procurement offices that are now handled at each field center. The consolidation is part of the One NASA focus. Six sites around the U.S. are under consideration by NASA.

    NASA Image and Video Library

    2004-02-19

    KENNEDY SPACE CENTER, FLA. - NASA Administrator Sean O’Keefe (center) is welcomed to the Central Florida Research Park, near Orlando. Central Florida leaders are proposing the research park as the site for the new NASA Shared Services Center. The center would centralize NASA’s payroll, accounting, human resources, facilities and procurement offices that are now handled at each field center. The consolidation is part of the One NASA focus. Six sites around the U.S. are under consideration by NASA.

  6. Helping small babies survive: an evaluation of facility-based Kangaroo Mother Care implementation progress in Uganda

    PubMed Central

    Aliganyira, Patrick; Kerber, Kate; Davy, Karen; Gamache, Nathalie; Sengendo, Namaala Hanifah; Bergh, Anne-Marie

    2014-01-01

    Introduction Prematurity is the leading cause of newborn death in Uganda, accounting for 38% of the nation's 39,000 annual newborn deaths. Kangaroo mother care is a high-impact; cost-effective intervention that has been prioritized in policy in Uganda but implementation has been limited. Methods A standardised, cross-sectional, mixed-method evaluation design was used, employing semi-structured key-informant interviews and observations in 11 health care facilities implementing kangaroo mother care in Uganda. Results The facilities visited scored between 8.28 and 21.72 out of the possible 30 points with a median score of 14.71. Two of the 3 highest scoring hospitals were private, not-for-profit hospitals whereas the second highest scoring hospital was a central teaching hospital. Facilities with KMC services are not equally distributed throughout the country. Only 4 regions (Central 1, Central 2, East-Central and Southwest) plus the City of Kampala were identified as having facilities providing KMC services. Conclusion KMC services are not instituted with consistent levels of quality and are often dependent on private partner support. With increasing attention globally and in country, Uganda is in a unique position to accelerate access to and quality of health services for small babies across the country. PMID:25667699

  7. Helping small babies survive: an evaluation of facility-based Kangaroo Mother Care implementation progress in Uganda.

    PubMed

    Aliganyira, Patrick; Kerber, Kate; Davy, Karen; Gamache, Nathalie; Sengendo, Namaala Hanifah; Bergh, Anne-Marie

    2014-01-01

    Prematurity is the leading cause of newborn death in Uganda, accounting for 38% of the nation's 39,000 annual newborn deaths. Kangaroo mother care is a high-impact; cost-effective intervention that has been prioritized in policy in Uganda but implementation has been limited. A standardised, cross-sectional, mixed-method evaluation design was used, employing semi-structured key-informant interviews and observations in 11 health care facilities implementing kangaroo mother care in Uganda. The facilities visited scored between 8.28 and 21.72 out of the possible 30 points with a median score of 14.71. Two of the 3 highest scoring hospitals were private, not-for-profit hospitals whereas the second highest scoring hospital was a central teaching hospital. Facilities with KMC services are not equally distributed throughout the country. Only 4 regions (Central 1, Central 2, East-Central and Southwest) plus the City of Kampala were identified as having facilities providing KMC services. KMC services are not instituted with consistent levels of quality and are often dependent on private partner support. With increasing attention globally and in country, Uganda is in a unique position to accelerate access to and quality of health services for small babies across the country.

  8. Centralized vs. Decentralized Child Mental Health Services

    PubMed Central

    Adams, Milton S.

    1977-01-01

    One of the basic tenets of the Community Mental Health Center movement is that services should be provided in the consumers' community. Various centers across the country have attempted to do this in either a centralized or decentralized fashion. Historically, most health services have been provided centrally, a good example being the traditional general hospital with its centralized medical services. Over the years, some of these services have become decentralized to take the form of local health centers, health maintenance organizations, community clinics, etc, and now various large mental health centers are also being broken down into smaller community units. An example of each type of mental health facility is delineated here. PMID:904014

  9. Centralized vs. decentralized child mental health services.

    PubMed

    Adams, M S

    1977-09-01

    One of the basic tenets of the Community Mental Health Center movement is that services should be provided in the consumers' community. Various centers across the country have attempted to do this in either a centralized or decentralized fashion. Historically, most health services have been provided centrally, a good example being the traditional general hospital with its centralized medical services. Over the years, some of these services have become decentralized to take the form of local health centers, health maintenance organizations, community clinics, etc, and now various large mental health centers are also being broken down into smaller community units. An example of each type of mental health facility is delineated here.

  10. Requirement for Parp-1 and DNA ligases 1 or 3 but not of Xrcc1 in chromosomal translocation formation by backup end joining

    PubMed Central

    Soni, Aashish; Siemann, Maria; Grabos, Martha; Murmann, Tamara; Pantelias, Gabriel E.; Iliakis, George

    2014-01-01

    In mammalian cells, ionizing radiation (IR)-induced DNA double-strand breaks (DSBs) are repaired in all phases of the cell cycle predominantly by classical, DNA-PK-dependent nonhomologous end joining (D-NHEJ). Homologous recombination repair (HRR) is functional during the S- and G2-phases, when a sister chromatid becomes available. An error-prone, alternative form of end joining, operating as backup (B-NHEJ) functions robustly throughout the cell cycle and particularly in the G2-phase and is thought to backup predominantly D-NHEJ. Parp-1, DNA-ligases 1 (Lig1) and 3 (Lig3), and Xrcc1 are implicated in B-NHEJ. Chromosome and chromatid translocations are manifestations of erroneous DSB repair and are crucial culprits in malignant transformation and IR-induced cell lethality. We analyzed shifts in translocation formation deriving from defects in D-NHEJ or HRR in cells irradiated in the G2-phase and identify B-NHEJ as the main DSB repair pathway backing up both of these defects at the cost of a large increase in translocation formation. Our results identify Parp-1 and Lig1 and 3 as factors involved in translocation formation and show that Xrcc1 reinforces the function of Lig3 in the process without being required for it. Finally, we demonstrate intriguing connections between B-NHEJ and DNA end resection in translocation formation and show that, as for D-NHEJ and HRR, the function of B-NHEJ facilitates the recovery from the G2-checkpoint. These observations advance our understanding of chromosome aberration formation and have implications for the mechanism of action of Parp inhibitors. PMID:24748665

  11. Percutaneous coronary intervention with off-site cardiac surgery backup for acute myocardial infarction as a strategy to reduce door-to-balloon time.

    PubMed

    Peels, Hans O; de Swart, Hans; Ploeg, Tjeerd V D; Hautvast, Raymond W; Cornel, Jan H; Arnold, Alf E; Wharton, Thomas P; Umans, Victor A

    2007-11-01

    We investigated whether primary percutaneous coronary intervention (PCI) for patients admitted with an acute ST-segment elevation myocardial infarction could be performed more rapidly and with comparable outcomes in a community hospital versus a tertiary center with cardiac surgery. We started the first PCI with an off-site surgery program in The Netherlands in 2002 and report the results of 439 consecutive patients. In the safety phase, 199 patients presenting with ST-segment elevation myocardial infarction were randomly assigned to treatment at our off-site center versus a more distant cardiac surgery center. In the confirmation phase, 240 consecutive patients were treated in the off-site hospital. Safety and efficacy end points were the rate of an angiographically successful PCI procedure (diameter stenosis <50% and Thrombolysis In Myocardial Infarction grade 3 flow) in the absence of major adverse cardiac and cerebrovascular events at 30 days. The randomization phase showed a 37-minute decrease in door-to-balloon time (p <0.001) with comparable procedural and clinical successes (91% Thrombolysis In Myocardial Infarction grade 3 flow in the 2 groups). In the confirmation phase, the 30-day rate without major adverse cardiac and cerebrovascular events was 95%. None of the 439 patients in the study required emergency surgery for failed primary PCI. In conclusion, time to treatment with primary PCI can be significantly shortened when treating patients in a community hospital setting with off-site cardiac surgery backup compared with transport for PCI to a referral center with on-site surgery. PCI at hospitals with off-site cardiac surgery backup can be considered a needed strategy to improve access to primary PCI for a larger segment of the population and can be delivered with a very favorable safety profile.

  12. State University of New York. Central Administration Costs. Report 92-S-104.

    ERIC Educational Resources Information Center

    New York State Office of the Comptroller, Albany. Div. of Management Audit.

    An evaluation was done of State University of New York (SUNY) Central Administration costs by comparing them to peer systems and by evaluating how economically its duties were carried out. Central Administration provides oversight and executive leadership to the system and manages budgeting, accounting, capital facilities, student affairs and…

  13. Peripherally inserted central catheters. Guidewire versus nonguidewire use: a comparative study.

    PubMed

    Loughran, S C; Edwards, S; McClure, S

    1992-01-01

    To date, no research articles have been published that explore the practice of using guidewires for placement of peripherally inserted central catheters. The literature contains speculations regarding the pros and cons of guidewire use. However, no studies to date have compared patient outcomes when peripherally inserted central catheter lines are inserted with and without guidewires. To examine the use of guidewires for peripherally inserted central lines, a comparative study was conducted at two acute care facilities, one using guidewires for insertion and one inserting peripherally inserted central catheter lines without guidewires. 109 catheters were studied between January 1, 1990 and January 1, 1991. The primary focus of this study was to examine whether guidewire use places patients at higher risk for catheter-related complications, particularly phlebitis. No significant differences in phlebitis rates between the two study sites were found. Other catheter-related and noncatheter-related complications were similar between the two facilities. The results of this study do not support the belief that guidewire use increases complication rates.

  14. Detail of bricked up storage vault opening Central of ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Detail of bricked up storage vault opening - Central of Georgia Railway, Savannah Repair Shops & Terminal Facilities, Brick Storage Vaults under Jones Street, Bounded by West Broad, Jones, West Boundary & Hull Streets, Savannah, Chatham County, GA

  15. FACILITY 713, HALLWAY LOOKING TOWARDS MASTER BEDROOM END, VIEW FACING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    FACILITY 713, HALLWAY LOOKING TOWARDS MASTER BEDROOM END, VIEW FACING NORTH. - Schofield Barracks Military Reservation, Central-Entry Single-Family Housing Type, Between Bragg & Grime Streets near Ayres Avenue, Wahiawa, Honolulu County, HI

  16. Development of a Medical Cyclotron Production Facility

    NASA Astrophysics Data System (ADS)

    Allen, Danny R.

    2003-08-01

    Development of a Cyclotron manufacturing facility begins with a business plan. Geographics, the size and activity of the medical community, the growth potential of the modality being served, and other business connections are all considered. This business used the customer base established by NuTech, Inc., an independent centralized nuclear pharmacy founded by Danny Allen. With two pharmacies in operation in Tyler and College Station and a customer base of 47 hospitals and clinics the existing delivery system and pharmacist staff is used for the cyclotron facility. We then added cyclotron products to contracts with these customers to guarantee a supply. We partnered with a company in the process of developing PET imaging centers. We then built an independent imaging center attached to the cyclotron facility to allow for the use of short-lived isotopes.

  17. Human resources for refraction services in Central Nepal.

    PubMed

    Kandel, Himal; Murthy, G V S; Bascaran, Covadonga

    2015-07-01

    Uncorrected refractive error is a public health problem globally and in Nepal. Planning of refraction services is hampered by a paucity of data. This study was conducted to determine availability and distribution of human resources for refraction, their efficiency, the type and extent of their training; the current service provision of refraction services and the unmet need in human resources for refraction in Central Nepal. This was a descriptive cross-sectional study. All refraction facilities in the Central Region were identified through an Internet search and interviews of key informants from the professional bodies and parent organisations of primary eye centres. A stratified simple random sampling technique was used to select 50 per cent of refraction facilities. The selected facilities were visited for primary data collection. Face-to-face interviews were conducted with the managers and the refractionists available in the facilities using a semi-structured questionnaire. Data was collected in 29 centres. All the managers (n=29; response rate 100 per cent) and 50 refractionists (Response rate 65.8 per cent) were interviewed. Optometrists and ophthalmic assistants were the main providers of refraction services (n=70, 92.11 per cent). They were unevenly distributed across the region, highly concentrated around urban areas. The median number of refractions per refractionist per year was 3,600 (IQR: 2,400 - 6,000). Interviewed refractionists stated that clients' knowledge, attitude and practice related factors such as lack of awareness of the need for refraction services and/or availability of existing services were the major barriers to the output of refraction services. The total number of refractions carried out in the Central Region per year was 653,176. An additional 170 refractionists would be needed to meet the unmet need of 1,323,234 refractions. The study findings demand a major effort to develop appropriately trained personnel when planning

  18. A Brief Study of Cafeteria Facilities and Operations, with Recommendations for Implementation.

    ERIC Educational Resources Information Center

    Okamura, James T.

    The facilities and operations of the school lunch program in the public schools of Hawaii are reviewed. Several types of school lunch programs are described including--(1) traditional school lunch programs, (2) kitchen and classroom dining, (3) central and decentralized dining, (4) home school-feeder school system, (5) central kitchen, and (6) the…

  19. Evaluation of selected elastomer O-ring pump seals for service at the Wilsonville, Alabama, Advanced Coal Liquefaction Research and Development Facility. [Ethylenepropylenediene monomer compounds

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Skena, C.C.; Keiser, J.R.

    1986-08-01

    Previous laboratory tests of elastomer O-rings in coal liquefaction solvents conducted at L'Garde, Inc., indicated that certain ethylenepropylenediene monomer (EPDM) compounds provided the best performance when a backup ring was used to limit swelling. Before service testing in a pump at the Wilsonville, Alabama, Advanced Coal Liquefaction Research and Development Facility, tests of six selected elastomers in the appropriate Wilsonville-produced solvent were conducted at Oak Ridge National Laboratory (ORNL). The ORNL tests measured the elastomers' changes in cross section, weight, density, and relative flexibility. Although two perfluoroelastomers showed less degradation of most properties during these tests, it was decided tomore » proceed with service testing of two EPDM elastomers because of their much lower cost. 5 refs., 14 figs., 7 tabs.« less

  20. Dual-Spool Turbine Facility Design Overview

    NASA Technical Reports Server (NTRS)

    Giel, Paul; Pachlhofer, Pete

    2003-01-01

    The next generation of aircraft engines, both commercial and military, will attempt to capitalize on the benefits of close-coupled, vaneless, counter-rotating turbine systems. Experience has shown that significant risks and challenges are present with close-coupled systems in terms of efficiency and durability. The UEET program needs to demonstrate aerodynamic loading and efficiency goals for close-coupled, reduced-stage HP/LP turbine systems as a Level 1 Milestone for FY05. No research facility exists in the U.S. to provide risk reduction for successful development of close-coupled, high and low pressure turbine systems for the next generations of engines. To meet these objectives, the design, construction, and integrated systems testing of a Dual-Spool Turbine Facility (DSTF) facility has been initiated at the NASA Glenn Research Center. The facility will be a warm (-IOOO'F), continuous flow facility for overall aerodynamic performance and detailed flow field measurement acquisition. The facility will have state-of-the-art instrumentation to capture flow physics details. Accurate and reliable speed control will be achieved by utilizing the existing Variable Frequency Drive System. Utilization of this and other existing GRC centralized utilities will reduce the overall construction costs. The design allows for future installation of a turbine inlet combustor profile simulator. This presentation details the objectives of the facility and the concepts used in specifying its capabilities. Some preliminary design results will be presented along with a discussion of plans and schedules.

  1. Mineral facilities of Europe

    USGS Publications Warehouse

    Almanzar, Francisco; Baker, Michael S.; Elias, Nurudeen; Guzman, Eric

    2010-01-01

    This map displays over 1,700 records of mineral facilities within the countries of Europe and western Eurasia. Each record represents one commodity and one facility type at a single geographic location. Facility types include mines, oil and gas fields, and plants, such as refineries, smelters, and mills. Common commodities of interest include aluminum, cement, coal, copper, gold, iron and steel, lead, nickel, petroleum, salt, silver, and zinc. Records include attributes, such as commodity, country, location, company name, facility type and capacity (if applicable), and latitude and longitude geographical coordinates (in both degrees-minutes-seconds and decimal degrees). The data shown on this map and in table 1 were compiled from multiple sources, including (1) the most recently available data from the U.S. Geological Survey (USGS) Minerals Yearbook (Europe and Central Eurasia volume), (2) mineral statistics and information from the USGS Minerals Information Web site (http://minerals.usgs.gov/minerals/pubs/country/europe.html), and (3) data collected by the USGS minerals information country specialists from sources, such as statistical publications of individual countries, annual reports and press releases of operating companies, and trade journals. Data reflect the most recently published table of industry structure for each country at the time of this publication. Additional information is available from the country specialists listed in table 2.

  2. 24. INTERIOR OF CENTRAL ROOM. BASE POWER PANEL VISIBLE ON ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    24. INTERIOR OF CENTRAL ROOM. BASE POWER PANEL VISIBLE ON RIGHT WALL OF HALLWAY. - Chollas Heights Naval Radio Transmitting Facility, Transmitter Building, 6410 Zero Road, San Diego, San Diego County, CA

  3. Fuel storage tanks at FAA facilities : Order 1050.15A : executive summary.

    DOT National Transportation Integrated Search

    1997-04-30

    The Federal Aviation Administration (FAA) has over 4,000 fuel storage tanks (FST) in its inventory. Most of these FSTs are underground storage tanks (UST) that contain fuel for emergency backup generators providing secondary power to air navigational...

  4. FACILITY 712, EXTERIOR DETAIL OF FIREPLACE AND LEADEDGLASS WINDOWS, VIEW ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    FACILITY 712, EXTERIOR DETAIL OF FIREPLACE AND LEADED-GLASS WINDOWS, VIEW FACING WEST. - Schofield Barracks Military Reservation, Central-Entry Single-Family Housing Type, Between Bragg & Grime Streets near Ayres Avenue, Wahiawa, Honolulu County, HI

  5. Grande Ronde Endemic Spring Chinook Salmon Supplementation Program: Facility Operations and Maintenance, 2002 Annual Report.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McLean, Michael L.; Seeger, Ryan; Hewitt, Laurie

    2003-03-01

    The Catherine Creek Acclimation Facility (CCAF) received 180,912 smolts from LFH. The size of the fish at delivery was 18.4 fish/lb. Volitional releases started 1 April 2002 with a total of 7,998 PIT-tagged fish (68,948 estimated total fish) migrating from the raceways during the volitional release period. Hourly detections of PIT-tagged fish showed that most of the fish left between 1400 and 2200 hours. The size of the fish remaining just before the forced release was 16.4 fish/lb. The total mortality for the acclimation period was 569 (0.3 %). No significant mortality related to disease was observed. The fish weremore » fed a total of 1,968 lbs of food for the acclimation period. The total number of fish released from the acclimation facility in 2002 was 180,343. The Upper Grande Ronde Acclimation Facility (UGRAF) received 201,958 smolts from LFH. The size of the fish at delivery was 17.4 fish/lb. On 3 March 2002 the water inflow to raceway 4 froze in the early morning hours and the entire raceway was lost. Volitional releases started 1 April 2002 with a total of 682 PIT-tagged fish (68,200 estimated total fish) migrating from the raceways during the volitional release period. Hourly detections of PIT-tagged fish showed that most of the fish left between 1500 and 2200 hours. The size of the fish left in the raceways just before the forced release was 18.3 fish/lb. The total mortality for the acclimation period not including raceway 4 was 402 (0.3 %). No significant mortality related to disease was observed. The fish were fed a total of 568 lbs of food for the acclimation period. The total number of fish released from the acclimation facility in 2002 was 151,444. Maintenance and repair activities were conducted at the acclimation facilities in 2002. Facility maintenance work consisted of snow removal, painting of building, installation of backup water supply system, construction of steps to intake area, improvements to raceway standpipes, removal of gravel from

  6. Key ecological challenges for closed systems facilities

    NASA Astrophysics Data System (ADS)

    Nelson, Mark; Dempster, William F.; Allen, John P.

    2013-07-01

    Closed ecological systems are desirable for a number of purposes. In space life support systems, material closure allows precious life-supporting resources to be kept inside and recycled. Closure in small biospheric systems facilitates detailed measurement of global ecological processes and biogeochemical cycles. Closed testbeds facilitate research topics which require isolation from the outside (e.g. genetically modified organisms; radioisotopes) so their ecological interactions and fluxes can be studied separate from interactions with the outside environment. But to achieve and maintain closure entails solving complex ecological challenges. These challenges include being able to handle faster cycling rates and accentuated daily and seasonal fluxes of critical life elements such as carbon dioxide, oxygen, water, macro- and mico-nutrients. The problems of achieving sustainability in closed systems for life support include how to handle atmospheric dynamics including trace gases, producing a complete human diet, recycling nutrients and maintaining soil fertility, the maintenance of healthy air and water and preventing the loss of critical elements from active circulation. In biospheric facilities, the challenge is also to produce analogues to natural biomes and ecosystems, studying processes of self-organization and adaptation in systems that allow specification or determination of state variables and cycles which may be followed through all interactions from atmosphere to soils. Other challenges include the dynamics and genetics of small populations, the psychological challenges for small isolated human groups and backup technologies and strategic options which may be necessary to ensure long-term operation of closed ecological systems.

  7. Future Facility: FAIR at GSI

    NASA Astrophysics Data System (ADS)

    Rosner, Guenther

    2007-05-01

    The Facility for Antiproton and Ion Research, FAIR, is a new particle accelerator facility to be built at the GSI site in Germany. The research at FAIR will cover a wide range of topics in nuclear and hadron physics, high density plasma and atomic physics, and applications in condensed matter physics and biology. A 1.1 km circumference double ring of rapidly cycling 100 and 300 Tm synchrotrons, will be FAIR's central accelerator system. It will be used to produce, inter alia, high intensity secondary beams of antiprotons and short-lived radioactive nuclei. A subsequent suite of cooler and storage rings will deliver heavy ion and antiproton beams of unprecedented quality. Large experiments are presently being designed by the NUSTAR, PANDA, PAX, CBM, SPARC, FLAIR, HEDgeHOB and BIOMAT collaborations.

  8. 18 CFR 367.1850 - Account 185, Temporary facilities.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Account 185, Temporary facilities. 367.1850 Section 367.1850 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY... POWER ACT AND NATURAL GAS ACT UNIFORM SYSTEM OF ACCOUNTS FOR CENTRALIZED SERVICE COMPANIES SUBJECT TO...

  9. Field Sampling Plan for Closure of the Central Facilities Area Sewage Treatment Plant Lagoon 3 and Land Application Area

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lewis, Michael George

    This field sampling plan describes sampling of the soil/liner of Lagoon 3 at the Central Facilities Area Sewage Treatment Plant. The lagoon is to be closed, and samples obtained from the soil/liner will provide information to determine if Lagoon 3 and the land application area can be closed in a manner that renders it safe to human health and the environment. Samples collected under this field sampling plan will be compared to Idaho National Laboratory background soil concentrations. If the concentrations of constituents of concern exceed the background level, they will be compared to Comprehensive Environmental Response, Compensation, and Liabilitymore » Act preliminary remediation goals and Resource Conservation and Recovery Act levels. If the concentrations of constituents of concern are lower than the background levels, Resource Conservation and Recovery Act levels, or the preliminary remediation goals, then Lagoon 3 and the land application area will be closed. If the Resource Conservation and Recovery Act levels and/or the Comprehensive Environmental Response, Compensation, and Liability Act preliminary remediation goals are exceeded, additional sampling and action may be required.« less

  10. Development of a Medical Cyclotron Production Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Allen, Danny R.

    Development of a Cyclotron manufacturing facility begins with a business plan. Geographics, the size and activity of the medical community, the growth potential of the modality being served, and other business connections are all considered. This business used the customer base established by NuTech, Inc., an independent centralized nuclear pharmacy founded by Danny Allen. With two pharmacies in operation in Tyler and College Station and a customer base of 47 hospitals and clinics the existing delivery system and pharmacist staff is used for the cyclotron facility. We then added cyclotron products to contracts with these customers to guarantee a supply.more » We partnered with a company in the process of developing PET imaging centers. We then built an independent imaging center attached to the cyclotron facility to allow for the use of short-lived isotopes.« less

  11. Infarct size in primary angioplasty without on-site cardiac surgical backup versus transferal to a tertiary center: a single photon emission computed tomography study.

    PubMed

    Knaapen, Paul; de Mulder, Maarten; van der Zant, Friso M; Peels, Hans O; Twisk, Jos W R; van Rossum, Albert C; Cornel, Jan H; Umans, Victor A W M

    2009-02-01

    Primary percutaneous coronary intervention (PCI) performed in large community hospitals without cardiac surgery back-up facilities (off-site) reduces door-to-balloon time compared with emergency transferal to tertiary interventional centers (on-site). The present study was performed to explore whether off-site PCI for acute myocardial infarction results in reduced infarct size. One hundred twenty-eight patients with acute ST-segment elevation myocardial infarction were randomly assigned to undergo primary PCI at the off-site center (n = 68) or to transferal to an on-site center (n = 60). Three days after PCI, (99m)Tc-sestamibi SPECT was performed to estimate infarct size. Off-site PCI significantly reduced door-to-balloon time compared with on-site PCI (94 +/- 54 versus 125 +/- 59 min, respectively, p < 0.01), although symptoms-to-treatment time was only insignificantly reduced (257 +/- 211 versus 286 +/- 146 min, respectively, p = 0.39). Infarct size was comparable between treatment centers (16 +/- 15 versus 14 +/- 12%, respectively p = 0.35). Multivariate analysis revealed that TIMI 0/1 flow grade at initial coronary angiography (OR 3.125, 95% CI 1.17-8.33, p = 0.023), anterior wall localization of the myocardial infarction (OR 3.44, 95% CI 1.38-8.55, p < 0.01), and development of pathological Q-waves (OR 5.07, 95% CI 2.10-12.25, p < 0.01) were independent predictors of an infarct size > 12%. Off-site PCI reduces door-to-balloon time compared with transferal to a remote on-site interventional center but does not reduce infarct size. Instead, pre-PCI TIMI 0/1 flow, anterior wall infarct localization, and development of Q-waves are more important predictors of infarct size.

  12. Biochemical evidence for Ku-independent backup pathways of NHEJ.

    PubMed

    Wang, Huichen; Perrault, Ange Ronel; Takeda, Yoshihiko; Qin, Wei; Wang, Hongyan; Iliakis, George

    2003-09-15

    Cells of higher eukaryotes process within minutes double strand breaks (DSBs) in their genome using a non-homologous end joining (NHEJ) apparatus that engages DNA-PKcs, Ku, DNA ligase IV, XRCC4 and other as of yet unidentified factors. Although chemical inhibition, or mutation, in any of these factors delays processing, cells ultimately remove the majority of DNA DSBs using an alternative pathway operating with an order of magnitude slower kinetics. This alternative pathway is active in mutants deficient in genes of the RAD52 epistasis group and frequently joins incorrect ends. We proposed, therefore, that it reflects an alternative form of NHEJ that operates as a backup (B-NHEJ) to the DNA-PK-dependent (D-NHEJ) pathway, rather than homology directed repair of DSBs. The present study investigates the role of Ku in the coordination of these pathways using as a model end joining of restriction endonuclease linearized plasmid DNA in whole cell extracts. Efficient, error-free, end joining observed in such in vitro reactions is strongly inhibited by anti-Ku antibodies. The inhibition requires DNA-PKcs, despite the fact that Ku efficiently binds DNA ends in the presence of antibodies, or in the absence of DNA-PKcs. Strong inhibition of DNA end joining is also mediated by wortmannin, an inhibitor of DNA-PKcs, in the presence but not in the absence of Ku, and this inhibition can be rescued by pre-incubating the reaction with double stranded oligonucleotides. The results are compatible with a role of Ku in directing end joining to a DNA-PK dependent pathway, mediated by efficient end binding and productive interactions with DNA-PKcs. On the other hand, efficient end joining is observed in extracts of cells lacking DNA-PKcs, as well as in Ku-depleted extracts in line with the operation of alternative pathways. Extracts depleted of Ku and DNA-PKcs rejoin blunt ends, as well as homologous ends with 3' or 5' protruding single strands with similar efficiency, but addition of Ku

  13. Biochemical evidence for Ku-independent backup pathways of NHEJ

    PubMed Central

    Wang, Huichen; Perrault, Ange Ronel; Takeda, Yoshihiko; Qin, Wei; Wang, Hongyan; Iliakis, George

    2003-01-01

    Cells of higher eukaryotes process within minutes double strand breaks (DSBs) in their genome using a non-homologous end joining (NHEJ) apparatus that engages DNA-PKcs, Ku, DNA ligase IV, XRCC4 and other as of yet unidentified factors. Although chemical inhibition, or mutation, in any of these factors delays processing, cells ultimately remove the majority of DNA DSBs using an alternative pathway operating with an order of magnitude slower kinetics. This alternative pathway is active in mutants deficient in genes of the RAD52 epistasis group and frequently joins incorrect ends. We proposed, therefore, that it reflects an alternative form of NHEJ that operates as a backup (B-NHEJ) to the DNA-PK-dependent (D-NHEJ) pathway, rather than homology directed repair of DSBs. The present study investigates the role of Ku in the coordination of these pathways using as a model end joining of restriction endonuclease linearized plasmid DNA in whole cell extracts. Efficient, error-free, end joining observed in such in vitro reactions is strongly inhibited by anti-Ku antibodies. The inhibition requires DNA-PKcs, despite the fact that Ku efficiently binds DNA ends in the presence of antibodies, or in the absence of DNA-PKcs. Strong inhibition of DNA end joining is also mediated by wortmannin, an inhibitor of DNA-PKcs, in the presence but not in the absence of Ku, and this inhibition can be rescued by pre-incubating the reaction with double stranded oligonucleotides. The results are compatible with a role of Ku in directing end joining to a DNA-PK dependent pathway, mediated by efficient end binding and productive interactions with DNA-PKcs. On the other hand, efficient end joining is observed in extracts of cells lacking DNA-PKcs, as well as in Ku-depleted extracts in line with the operation of alternative pathways. Extracts depleted of Ku and DNA-PKcs rejoin blunt ends, as well as homologous ends with 3′ or 5′ protruding single strands with similar efficiency, but addition of

  14. Requirement for Parp-1 and DNA ligases 1 or 3 but not of Xrcc1 in chromosomal translocation formation by backup end joining.

    PubMed

    Soni, Aashish; Siemann, Maria; Grabos, Martha; Murmann, Tamara; Pantelias, Gabriel E; Iliakis, George

    2014-06-01

    In mammalian cells, ionizing radiation (IR)-induced DNA double-strand breaks (DSBs) are repaired in all phases of the cell cycle predominantly by classical, DNA-PK-dependent nonhomologous end joining (D-NHEJ). Homologous recombination repair (HRR) is functional during the S- and G2-phases, when a sister chromatid becomes available. An error-prone, alternative form of end joining, operating as backup (B-NHEJ) functions robustly throughout the cell cycle and particularly in the G2-phase and is thought to backup predominantly D-NHEJ. Parp-1, DNA-ligases 1 (Lig1) and 3 (Lig3), and Xrcc1 are implicated in B-NHEJ. Chromosome and chromatid translocations are manifestations of erroneous DSB repair and are crucial culprits in malignant transformation and IR-induced cell lethality. We analyzed shifts in translocation formation deriving from defects in D-NHEJ or HRR in cells irradiated in the G2-phase and identify B-NHEJ as the main DSB repair pathway backing up both of these defects at the cost of a large increase in translocation formation. Our results identify Parp-1 and Lig1 and 3 as factors involved in translocation formation and show that Xrcc1 reinforces the function of Lig3 in the process without being required for it. Finally, we demonstrate intriguing connections between B-NHEJ and DNA end resection in translocation formation and show that, as for D-NHEJ and HRR, the function of B-NHEJ facilitates the recovery from the G2-checkpoint. These observations advance our understanding of chromosome aberration formation and have implications for the mechanism of action of Parp inhibitors. © The Author(s) 2014. Published by Oxford University Press on behalf of Nucleic Acids Research.

  15. An overview of current activities at the National Solar Thermal Test Facility

    NASA Astrophysics Data System (ADS)

    Cameron, C. P.; Klimas, P. C.

    This paper is a description of the United States Department of Energy's National Solar Thermal Test Facility, highlighting current test programs. In the central receiver area, research underway supports commercialization of molten nitrate salt technology, including receivers, thermal energy transport, and corrosion experiments. Concentrator research includes large-area, glass-metal heliostats and stretched-membrane heliostats and dishes. Test activities in support of dish-Stirling systems with reflux receivers are described. Research on parabolic troughs includes characterization of several receiver configurations. Other test facility activities include solar detoxification experiments, design assistance testing of commercially-available solar hardware, and non-DOE-funded work, including thermal exposure tests and testing of volumetric and PV central receiver concepts.

  16. Achieving and documenting closure in plant growth facilities

    NASA Technical Reports Server (NTRS)

    Knott, W. M.; Sager, John C.; Wheeler, Ray

    1992-01-01

    As NASA proceeds with its effort to develop a Controlled Ecological Life Support System (CELSS) that will provide life support to crews during long duration space missions, it must address the question of facility and system closure. The concept of closure as it pertains to CELSS and engineering specifications, construction problems and monitoring procedures used in the development and operation of a closed plant growth facility for the CELSS program are described. A plant growth facility is one of several modules required for a CELSS. A prototype of this module at Kennedy Space Center is the large (7m tall x 3.5m diameter) Biomass Production Chamber (BPC), the central facility of the CELSS Breadboard Project. The BPC is atmospherically sealed to a leak rate of approximately 5 percent of its total volume per 24 hours. This paper will discuss the requirements for atmospheric closure in the facility, present CO2 and trace gas data from initial tests of the BPC with and without plants, and describe how the chamber was sealed atmospherically. Implications that research conducted in this type of facility will have for the CELSS program are discussed.

  17. A Sketch of the Taiwan Zebrafish Core Facility.

    PubMed

    You, May-Su; Jiang, Yun-Jin; Yuh, Chiou-Hwa; Wang, Chien-Ming; Tang, Chih-Hao; Chuang, Yung-Jen; Lin, Bo-Hung; Wu, Jen-Leih; Hwang, Sheng-Ping L

    2016-07-01

    In the past three decades, the number of zebrafish laboratories has significantly increased in Taiwan. The Taiwan Zebrafish Core Facility (TZCF), a government-funded core facility, was launched to serve this growing community. The Core Facility was built on two sites, one located at the National Health Research Institutes (NHRI, called Taiwan Zebrafish Core Facility at NHRI or TZeNH) and the other is located at the Academia Sinica (Taiwan Zebrafish Core Facility at AS a.k.a. TZCAS). The total surface area of the TZCF is about 180 m(2) encompassing 2880 fish tanks. Each site has a separate quarantine room and centralized water recirculating systems, monitoring key water parameters. To prevent diseases, three main strategies have been implemented: (1) imported fish must be quarantined; (2) only bleached embryos are introduced into the main facilities; and (3) working practices were implemented to minimize pathogen transfer between stocks and facilities. Currently, there is no health program in place; however, a fourth measure for the health program, specific regular pathogen tests, is being planned. In March 2015, the TZCF at NHRI has been AAALAC accredited. It is our goal to ensure that we provide "disease-free" fish and embryos to the Taiwanese research community.

  18. KENNEDY SPACE CENTER, FLA. - NASA Administrator Sean O’Keefe (left) greets U.S. Representative Ric Keller during a tour of the Central Florida Research Park, near Orlando. Central Florida leaders are proposing the research park as the site for the new NASA Shared Services Center. The center would centralize NASA’s payroll, accounting, human resources, facilities and procurement offices that are now handled at each field center. The consolidation is part of the One NASA focus. Six sites around the U.S. are under consideration by NASA.

    NASA Image and Video Library

    2004-02-19

    KENNEDY SPACE CENTER, FLA. - NASA Administrator Sean O’Keefe (left) greets U.S. Representative Ric Keller during a tour of the Central Florida Research Park, near Orlando. Central Florida leaders are proposing the research park as the site for the new NASA Shared Services Center. The center would centralize NASA’s payroll, accounting, human resources, facilities and procurement offices that are now handled at each field center. The consolidation is part of the One NASA focus. Six sites around the U.S. are under consideration by NASA.

  19. KENNEDY SPACE CENTER, FLA. - NASA Administrator Sean O’Keefe (right) greets Florida Congressman Tom Feeney during a tour of the Central Florida Research Park, near Orlando. Central Florida leaders are proposing the research park as the site for the new NASA Shared Services Center. The center would centralize NASA’s payroll, accounting, human resources, facilities and procurement offices that are now handled at each field center. The consolidation is part of the One NASA focus. Six sites around the U.S. are under consideration by NASA.

    NASA Image and Video Library

    2004-02-19

    KENNEDY SPACE CENTER, FLA. - NASA Administrator Sean O’Keefe (right) greets Florida Congressman Tom Feeney during a tour of the Central Florida Research Park, near Orlando. Central Florida leaders are proposing the research park as the site for the new NASA Shared Services Center. The center would centralize NASA’s payroll, accounting, human resources, facilities and procurement offices that are now handled at each field center. The consolidation is part of the One NASA focus. Six sites around the U.S. are under consideration by NASA.

  20. Space Station Furnace Facility. Experiment/Facility Requirements Document (E/FRD), volume 2, appendix 5

    NASA Technical Reports Server (NTRS)

    Kephart, Nancy

    1992-01-01

    The function of the Space Station Furnace Facility (SSFF) is to support materials research into the crystal growth and solidification processes of electronic and photonic materials, metals and alloys, and glasses and ceramics. To support this broad base of research requirements, the SSFF will employ a variety of furnace modules operated, regulated, and supported by a core of common subsystems. Furnace modules may be reconfigured or specifically developed to provide unique solidifcation conditions for each set of experiments. The SSFF modular approach permits the addition of new or scaled-up furnace modules to support the evolution of the facility as new science requirements are identified. The SSFF Core is of modular design to permit augmentation for enhanced capabilities. The fully integrated configuration of the SSFF will consist of three racks with the capability of supporting up to two furnace modules per rack. The initial configuration of the SSFF will consist of two of the three racks and one furnace module. This Experiment/Facility Requirements Document (E/FRD) describes the integrated facility requirements for the Space Station Freedom (SSF) Integrated Configuration-1 (IC1) mission. The IC1 SSFF will consist of two racks: the Core Rack, with the centralized subsystem equipment, and the Experiment Rack-1, with Furnace Module-1 and the distributed subsystem equipment to support the furnace.

  1. Central Campus Construction Progress

    NASA Image and Video Library

    2016-10-18

    The new headquarters building’s seven floors are clearly visible as construction continues in the industrial area at NASA’s Kennedy Space Center in Florida. The 200,000-square-foot facility will anchor the spaceport’s Central Campus and house about 500 NASA civil service and contractor employees. The building will be more energy efficient than the current Headquarters building and will feature the latest in office and administrative building technology to fulfill Kennedy's role as the premiere multi-user spaceport for NASA and, increasingly, commercial entities.

  2. Refurbishment and Automation of Thermal Vacuum Facilities at NASA/GSFC

    NASA Technical Reports Server (NTRS)

    Dunn, Jamie; Gomez, Carlos; Donohue, John; Johnson, Chris; Palmer, John; Sushon, Janet

    1999-01-01

    The thermal vacuum facilities located at the Goddard Space Flight Center (GSFC) have supported both manned and unmanned space flight since the 1960s. Of the eleven facilities, currently ten of the systems are scheduled for refurbishment or replacement as part of a five-year implementation. Expected return on investment includes the reduction in test schedules, improvements in safety of facility operations, and reduction in the personnel support required for a test. Additionally, GSFC will become a global resource renowned for expertise in thermal engineering, mechanical engineering, and for the automation of thermal vacuum facilities and tests. Automation of the thermal vacuum facilities includes the utilization of Programmable Logic Controllers (PLCs), the use of Supervisory Control and Data Acquisition (SCADA) systems, and the development of a centralized Test Data Management System. These components allow the computer control and automation of mechanical components such as valves and pumps. The project of refurbishment and automation began in 1996 and has resulted in complete computer control of one facility (Facility 281), and the integration of electronically controlled devices and PLCs in multiple others.

  3. Refurbishment and Automation of Thermal Vacuum Facilities at NASA/GSFC

    NASA Technical Reports Server (NTRS)

    Dunn, Jamie; Gomez, Carlos; Donohue, John; Johnson, Chris; Palmer, John; Sushon, Janet

    1998-01-01

    The thermal vacuum facilities located at the Goddard Space Flight Center (GSFC) have supported both manned and unmanned space flight since the 1960s. Of the eleven facilities, currently ten of the systems are scheduled for refurbishment or replacement as part of a five-year implementation. Expected return on investment includes the reduction in test schedules, improvements in safety of facility operations, and reduction in the personnel support required for a test. Additionally, GSFC will become a global resource renowned for expertise in thermal engineering, mechanical engineering, and for the automation of thermal vacuum facilities and tests. Automation of the thermal vacuum facilities includes the utilization of Programmable Logic Controllers (PLCs), the use of Supervisory Control and Data Acquisition (SCADA) systems, and the development of a centralized Test Data Management System. These components allow the computer control and automation of mechanical components such as valves and pumps. The project of refurbishment and automation began in 1996 and has resulted in complete computer control of one facility (Facility 281), and the integration of electronically controlled devices and PLCs in multiple others.

  4. Central Radar System, Over-the-Horizon Backscatter

    DTIC Science & Technology

    1990-03-09

    1,2-Dibromo-3- chloropropane (DBCP) 0.3 TABLE 41-6 (Continued). MINNESOTA RECOMMENDED ALLOWABLE LIMITS (RAL) FOR DRINKING WATER WELLS Compound RAL (ug/ 1 ...TABLE OF CONTENTS ENVIRONMENTAL IMPACT ANALYSIS PROCESS OVERVIEW ............ TECHNICAL STUDY 1 FACILITIES...TECHNICAL STUDY 10 0 TECHNICAL STUDY 1 CENTRAL RADAR SYSTEM OVER-THE-HORIZON BACKSCATTER RADAR PROGRAM 0 ENVIRONMENTAL IMPACT

  5. Spatial Distribution Characteristics of Healthcare Facilities in Nanjing: Network Point Pattern Analysis and Correlation Analysis.

    PubMed

    Ni, Jianhua; Qian, Tianlu; Xi, Changbai; Rui, Yikang; Wang, Jiechen

    2016-08-18

    The spatial distribution of urban service facilities is largely constrained by the road network. In this study, network point pattern analysis and correlation analysis were used to analyze the relationship between road network and healthcare facility distribution. The weighted network kernel density estimation method proposed in this study identifies significant differences between the outside and inside areas of the Ming city wall. The results of network K-function analysis show that private hospitals are more evenly distributed than public hospitals, and pharmacy stores tend to cluster around hospitals along the road network. After computing the correlation analysis between different categorized hospitals and street centrality, we find that the distribution of these hospitals correlates highly with the street centralities, and that the correlations are higher with private and small hospitals than with public and large hospitals. The comprehensive analysis results could help examine the reasonability of existing urban healthcare facility distribution and optimize the location of new healthcare facilities.

  6. Room To Grow? Facilities Programming for Colleges and Universities.

    ERIC Educational Resources Information Center

    Thompson, Roger; Adams, Tom

    2001-01-01

    Asserts that campus space needs could be remedied by moving centrally located service delivery organizations, such as fleet vehicle maintenance facilities. Describes the process of operational and space needs assessment; this process provides information that enables architects to plan for appropriate adjacencies, correct space allocation, and…

  7. FACILITY 713, DINING ROOM CABINET DOORS AND DOORS FROM LIVING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    FACILITY 713, DINING ROOM CABINET DOORS AND DOORS FROM LIVING ROOM TO ENTRY PORCH IN RIGHT BACKGROUND, VIEW FACING NORTHWEST. - Schofield Barracks Military Reservation, Central-Entry Single-Family Housing Type, Between Bragg & Grime Streets near Ayres Avenue, Wahiawa, Honolulu County, HI

  8. The performance of two automatic servo-ventilation devices in the treatment of central sleep apnea.

    PubMed

    Javaheri, Shahrokh; Goetting, Mark G; Khayat, Rami; Wylie, Paul E; Goodwin, James L; Parthasarathy, Sairam

    2011-12-01

    This study was conducted to evaluate the therapeutic performance of a new auto Servo Ventilation device (Philips Respironics autoSV Advanced) for the treatment of complex central sleep apnea (CompSA). The features of autoSV Advanced include an automatic expiratory pressure (EPAP) adjustment, an advanced algorithm for distinguishing open versus obstructed airway apnea, a modified auto backup rate which is proportional to subject's baseline breathing rate, and a variable inspiratory support. Our primary aim was to compare the performance of the advanced servo-ventilator (BiPAP autoSV Advanced) with conventional servo-ventilator (BiPAP autoSV) in treating central sleep apnea (CSA). A prospective, multicenter, randomized, controlled trial. Five sleep laboratories in the United States. Thirty-seven participants were included. All subjects had full night polysomnography (PSG) followed by a second night continuous positive airway pressure (CPAP) titration. All had a central apnea index ≥ 5 per hour of sleep on CPAP. Subjects were randomly assigned to 2 full-night PSGs while treated with either the previously marketed autoSV, or the new autoSV Advanced device. The 2 randomized sleep studies were blindly scored centrally. Across the 4 nights (PSG, CPAP, autoSV, and autoSV Advanced), the mean ± 1 SD apnea hypopnea indices were 53 ± 23, 35 ± 20, 10 ± 10, and 6 ± 6, respectively; indices for CSA were 16 ± 19, 19 ± 18, 3 ± 4, and 0.6 ± 1. AutoSV Advanced was more effective than other modes in correcting sleep related breathing disorders. BiPAP autoSV Advanced was more effective than conventional BiPAP autoSV in the treatment of sleep disordered breathing in patients with CSA.

  9. Central Campus Construction Progress

    NASA Image and Video Library

    2016-10-18

    A large crane towers overhead as the new, seven-story headquarters building takes shape in the industrial area at NASA’s Kennedy Space Center in Florida. The 200,000-square-foot facility will anchor the spaceport’s Central Campus and house about 500 NASA civil service and contractor employees. The building will be more energy efficient than the current Headquarters building and will feature the latest in office and administrative building technology to fulfill Kennedy's role as the premiere multi-user spaceport for NASA and, increasingly, commercial entities.

  10. 76 FR 72993 - Options Price Reporting Authority; Notice of Filing and Immediate Effectiveness of Proposed...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-28

    ... that act as ``hot'' back-up sites for each other, OPRA will consider the sites not to be DR facilities...-2011-05 on the subject line. Paper Comments Send paper comments in triplicate to Elizabeth M. Murphy...

  11. Effect of electronic ANR and conventional hearing protectors on vehicle backup alarm detection in noise.

    PubMed

    Casali, John G; Robinson, Gary S; Dabney, Erika Christian; Gauger, Dan

    2004-01-01

    An experiment was conducted wherein masked thresholds (using ascending method of limits) for a backup alarm were obtained in pink and red noise at 85 and 100 dBA for 12 participants immersed in a probability monitoring task and wearing a conventional passive hearing protection device (HPD, an earmuff or a foam earplug), an active noise reduction (ANR) headset, or no HPD at all (only in 85 dBA noise). Results revealed statistically significant between-HPD differences in red noise (from 2.3 to 3.1 dB) and in the 100-dBA noise level (from 2.6 to 4.3 dB). An additional finding, which corroborates other studies using different protocols, was that masked thresholds in 85-dBA noise were significantly lower (from 3.2 to 4.4 dB) for the occluded conditions (wearing an HPD) than for the open-ear (unoccluded) condition. This result refutes the belief among many normal-hearing workers that the use of HPDs in relatively low levels of noise compromises their ability to hear necessary workplace sounds. Actual or potential applications of this research include (a) the selection of appropriate HPDs for low-frequency-biased noise exposures wherein signal detection is important and (b) gaining insight into the appropriateness of ANR-based HPDs for certain industrial noise environments.

  12. The Central Laser Facility at the Pierre Auger Observatory: Studies of the Atmospheric Vertical Aerosol Optical Depth and other Applications to Cosmic Ray Measurements

    NASA Astrophysics Data System (ADS)

    Medina Hernandez, Carlos Francisco

    The two largest observatories in the world dedicated to the study of Ultra High Energy Cosmic Rays (UHECR) are the Pierre Auger Observatory (Auger) in Mendoza, Argentina and the Telescope Array (TA) in Utah, USA. The measurements of the cosmic ray flux by Auger and TA present a discrepancy at the highest part of the energy spectrum. In this thesis, I study if this discrepancy can be attributed to instrumental effects related to the measurements of the atmospheric aerosol contents in Auger. The Auger Fluorescence Detector (FD) measures the scattered light from laser tracks generated by the Central Laser Facility (CLF) and the eXtreme Laser Facility (XLF) located near the center of Auger, to estimate the vertical aerosol optical depth (tau (z,t)). A good knowledge of tau (z,t) is needed to obtain unbiased and reliable FD measurements of the energy of the UHECR primary particle. The CLF was upgraded substantially in 2013 to improve laser reliability. A substantial part of my Ph.D work is dedicated to building, maintaining and analyzing data from this upgraded facility. The upgraded CLF includes a backscatter Raman LIDAR which independently measures tau (z,t). For the first time in a cosmic ray experiment, two years of measurements of tau (z,t) obtained with the Raman LIDAR are compared with the measurements obtained with the FD. Based on these comparisons, an alternative atmospheric database was created to study its effects on the measurements of the flux as a function of energy. The resulting energy spectrum plot is found to be more compatible with the energy spectrum plot released by TA.

  13. Lower initial central venous pressure in septic patients from long-term care facilities than in those from the community.

    PubMed

    Lin, Chun-Yu; Chen, Tun-Chieh; Lu, Po-Liang; Chen, Hui-Juan; Bojang, Kebba S; Chen, Yen-Hsu

    2014-10-01

    The cornerstone of emergency management of severe sepsis and septic shock is early (within 6 hours) goal-directed therapy, including maintenance of central venous pressure (CVP) at 8-12 mmHg. It is unclear whether there is a difference in initial (baseline) CVP between septic patients who are referred from the community and those who come from long-term care facilities (LTCFs) in Taiwan. We designed this study to investigate the difference in hemodynamic parameters between these two groups. Every patient with severe sepsis or septic shock who had a central venous catheter inserted via the internal jugular or subclavian vein at Kaohsiung Medical University Hospital between April 2007 and October 2007 was enrolled. CVP was measured immediately at the emergency department. Patient demographics, including residence, were retrospectively recorded and analyzed. There were 166 evaluable patients; 125 (75.3%) came from the community and 41 (24.7%) from LTCFs. There were no significant differences in age, sex, initial body temperature, heart rate, blood pressure, or leukocyte count between the two groups. However, patients who were referred from LTCFs had a significantly lower initial CVP than those from the community (5.0 ± 4.5 mmHg vs. 7.0 ± 4.8 mmHg, p = 0.023). The difference was more significant between mechanically ventilated patients from LTCFs and those from the community (5.0 ± 3.0 mmHg vs. 8.1 ± 5.6 mmHg, p = 0.006). Severely septic patients referred from LTCFs may require more aggressive fluid resuscitation within the first 6 hours of the diagnostic criteria met at the emergency department to achieve the CVP target of early goal-directed therapy. Copyright © 2013. Published by Elsevier B.V.

  14. Improved earthquake monitoring in the central and eastern United States in support of seismic assessments for critical facilities

    USGS Publications Warehouse

    Leith, William S.; Benz, Harley M.; Herrmann, Robert B.

    2011-01-01

    Evaluation of seismic monitoring capabilities in the central and eastern United States for critical facilities - including nuclear powerplants - focused on specific improvements to understand better the seismic hazards in the region. The report is not an assessment of seismic safety at nuclear plants. To accomplish the evaluation and to provide suggestions for improvements using funding from the American Recovery and Reinvestment Act of 2009, the U.S. Geological Survey examined addition of new strong-motion seismic stations in areas of seismic activity and addition of new seismic stations near nuclear power-plant locations, along with integration of data from the Transportable Array of some 400 mobile seismic stations. Some 38 and 68 stations, respectively, were suggested for addition in active seismic zones and near-power-plant locations. Expansion of databases for strong-motion and other earthquake source-characterization data also was evaluated. Recognizing pragmatic limitations of station deployment, augmentation of existing deployments provides improvements in source characterization by quantification of near-source attenuation in regions where larger earthquakes are expected. That augmentation also supports systematic data collection from existing networks. The report further utilizes the application of modeling procedures and processing algorithms, with the additional stations and the improved seismic databases, to leverage the capabilities of existing and expanded seismic arrays.

  15. Challenges for Nurses Caring for Patients With Peripherally Inserted Central Catheters in Skilled Nursing Facilities

    PubMed Central

    Harrod, Molly; Montoya, Ana; Mody, Lona; McGuirk, Helen; Winter, Suzanne; Chopra, Vineet

    2016-01-01

    Objectives To understand frontline nurses’ (registered nurses and licensed practical nurses), unit nurse managers’ and skilled nursing facility (SNF) administrators’ perceived preparedness in providing care for patients with peripherally inserted central catheters (PICCs) in SNFs. Design An exploratory, qualitative pilot study. Setting Two community based SNFs. Participants Patients, frontline nurses (registered nurses and licensed practical nurses), unit nurse managers and SNF administrators. Methods Over 36-weeks, we observed and conducted informal interviews with 56 patients with PICCs and their nurses focusing on PICC care practices and documentation. In addition, we collected baseline PICC data including placement indication (e.g., antimicrobial administration), placement setting (hospital vs. SNF), and dwell time. We then conducted focus groups with frontline nurses and unit nurse managers and semi-structured interviews with SNF administrators to evaluate perceived preparedness for PICC care. Data were analyzed using a descriptive analysis approach. Results During weekly informal interviews and observations variations in documentation were observed. Differences between patient-reported PICC concerns (quality-of-life) and those described by frontline nurses were noted. Deficiencies in communication between hospitals and SNFs with respect to device care, date of last dressing change and PICC removal time were also noted. During focus group sessions, perceived inadequacy of information at the time of care transitions, limited availability of resources to care for PICCs and gaps in training and education were highlighted as barriers in improving practice and safety. Conclusion Our study suggests that practices for PICC care in SNFs can be improved. Multimodal strategies that enhance staff education, improve information exchange during care transitions and increase resource availability in SNFs appear necessary to enhance PICC care and patient safety. PMID

  16. Challenges for Nurses Caring for Individuals with Peripherally Inserted Central Catheters in Skilled Nursing Facilities.

    PubMed

    Harrod, Molly; Montoya, Ana; Mody, Lona; McGuirk, Helen; Winter, Suzanne; Chopra, Vineet

    2016-10-01

    To understand the perceived preparedness of frontline nurses (registered nurses (RNs), licensed practical nurses (LPNs)), unit nurse managers, and skilled nursing facility (SNF) administrators in providing care for residents with peripherally inserted central catheters (PICCs) in SNFs. Exploratory, qualitative pilot study. Two community based SNFs. Residents with PICCs, frontline nurses (RNs, LPNs), unit nurse managers, and SNF administrators. Over 36 weeks, 56 residents with PICCs and their nurses were observed and informally interviewed, focusing on PICC care practices and documentation. In addition, baseline PICC data were collected on placement indication (e.g., antimicrobial administration), placement setting (hospital vs SNF), and dwell time. Focus groups were then conducted with frontline nurses and unit nurse managers, and semistructured interviews were conducted with SNF administrators to evaluate perceived preparedness for PICC care. Data were analyzed using a descriptive analysis approach. Variations in documentation were observed during weekly informal interviews and observations. Differences were noted between resident self-reported PICC concerns (quality of life) and those described by frontline nurses. Deficiencies in communication between hospitals and SNFs with respect to device care, date of last dressing change, and PICC removal time were also noted. During focus group sessions, perceived inadequacy of information at the time of care transitions, limited availability of resources to care for PICCs, and gaps in training and education were highlighted as barriers to improving practice and safety. Practices for PICC care in SNFs can be improved. Multimodal strategies that enhance staff education, improve information exchange during care transitions, and increase resource availability in SNFs appear necessary to enhance PICC care and safety. © 2016, Copyright the Authors Journal compilation © 2016, The American Geriatrics Society.

  17. FACILITY 713, LIVING ROOM SHOWING DIAMONDPANED WINDOWS FLANKING THE FIREPLACE, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    FACILITY 713, LIVING ROOM SHOWING DIAMOND-PANED WINDOWS FLANKING THE FIREPLACE, AND LEADED-GLASS WINDOWS IN DINING ROOM IN RIGHT BACKGROUND, VIEW FACING SOUTHEAST. - Schofield Barracks Military Reservation, Central-Entry Single-Family Housing Type, Between Bragg & Grime Streets near Ayres Avenue, Wahiawa, Honolulu County, HI

  18. Energy efficiency in California laboratory-type facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mills, E.; Bell, G.; Sartor, D.

    The central aim of this project is to provide knowledge and tools for increasing the energy efficiency and performance of new and existing laboratory-type facilities in California. We approach the task along three avenues: (1) identification of current energy use and savings potential, (2) development of a {ital Design guide for energy- Efficient Research Laboratories}, and (3) development of a research agenda for focused technology development and improving out understanding of the market. Laboratory-type facilities use a considerable amount of energy resources. They are also important to the local and state economy, and energy costs are a factor in themore » overall competitiveness of industries utilizing laboratory-type facilities. Although the potential for energy savings is considerable, improving energy efficiency in laboratory-type facilities is no easy task, and there are many formidable barriers to improving energy efficiency in these specialized facilities. Insufficient motivation for individual stake holders to invest in improving energy efficiency using existing technologies as well as conducting related R&D is indicative of the ``public goods`` nature of the opportunity to achieve energy savings in this sector. Due to demanding environmental control requirements and specialized processes, laboratory-type facilities epitomize the important intersection between energy demands in the buildings sector and the industrial sector. Moreover, given the high importance and value of the activities conducted in laboratory-type facilities, they represent one of the most powerful contexts in which energy efficiency improvements stand to yield abundant non-energy benefits if properly applied.« less

  19. An electric propulsion long term test facility

    NASA Technical Reports Server (NTRS)

    Trump, G.; James, E.; Vetrone, R.; Bechtel, R.

    1979-01-01

    An existing test facility was modified to provide for extended testing of multiple electric propulsion thruster subsystems. A program to document thruster subsystem characteristics as a function of time is currently in progress. The facility is capable of simultaneously operating three 2.7-kW, 30-cm mercury ion thrusters and their power processing units. Each thruster is installed via a separate air lock so that it can be extended into the 7m x 10m main chamber without violating vacuum integrity. The thrusters exhaust into a 3m x 5m frozen mercury target. An array of cryopanels collect sputtered target material. Power processor units are tested in an adjacent 1.5m x 2m vacuum chamber or accompanying forced convection enclosure. The thruster subsystems and the test facility are designed for automatic unattended operation with thruster operation computer controlled. Test data are recorded by a central data collection system scanning 200 channels of data a second every two minutes. Results of the Systems Demonstration Test, a short shakedown test of 500 hours, and facility performance during the first year of testing are presented.

  20. KENNEDY SPACE CENTER, FLA. - KSC Director Jim Kennedy (center) makes a presentation to NASA and other officials about the benefits of locating NASA’s new Shared Services Center in the Central Florida Research Park, near Orlando. Central Florida leaders are proposing the research park as the site for the NASA Shared Services Center. The center would centralize NASA’s payroll, accounting, human resources, facilities and procurement offices that are now handled at each field center. The consolidation is part of the One NASA focus. Six sites around the U.S. are under consideration by NASA.

    NASA Image and Video Library

    2004-02-19

    KENNEDY SPACE CENTER, FLA. - KSC Director Jim Kennedy (center) makes a presentation to NASA and other officials about the benefits of locating NASA’s new Shared Services Center in the Central Florida Research Park, near Orlando. Central Florida leaders are proposing the research park as the site for the NASA Shared Services Center. The center would centralize NASA’s payroll, accounting, human resources, facilities and procurement offices that are now handled at each field center. The consolidation is part of the One NASA focus. Six sites around the U.S. are under consideration by NASA.

  1. Contamination of the cold water distribution system of health care facilities by Legionella pneumophila: do we know the true dimension?

    PubMed

    Arvand, M; Jungkind, K; Hack, A

    2011-04-21

    German water guidelines do not recommend routine assessment of cold water for Legionella in healthcare facilities, except if the water temperature at distal sites exceeds 25°C. This study evaluates Legionella contamination in cold and warm water supplies of healthcare facilities in Hesse, Germany, and analyses the relationship between cold water temperature and Legionella contamination. Samples were collected from four facilities, with cases of healthcare-associated Legionnaires' disease or notable contamination of their water supply. Fifty-nine samples were from central lines and 625 from distal sites, comprising 316 cold and 309 warm water samples. Legionella was isolated from central lines in two facilities and from distal sites in four facilities. 17% of all central and 32% of all distal samples were contaminated. At distal sites, cold water samples were more frequently contaminated with Legionella (40% vs 23%, p <0.001) and with higher concentrations of Legionella (≥1,000 colony-forming unit/100 ml) (16% vs 6%, p<0.001) than warm water samples. There was no clear correlation between the cold water temperature at sampling time and the contamination rate. 35% of cold water samples under 20 °C at collection were contaminated. Our data highlight the importance of assessing the cold water supply of healthcare facilities for Legionella in the context of an intensified analysis.

  2. Nike Facility Diagnostics and Data Acquisition System

    NASA Astrophysics Data System (ADS)

    Chan, Yung; Aglitskiy, Yefim; Karasik, Max; Kehne, David; Obenschain, Steve; Oh, Jaechul; Serlin, Victor; Weaver, Jim

    2013-10-01

    The Nike laser-target facility is a 56-beam krypton fluoride system that can deliver 2 to 3 kJ of laser energy at 248 nm onto targets inside a two meter diameter vacuum chamber. Nike is used to study physics and technology issues related to laser direct-drive ICF fusion, including hydrodynamic and laser-plasma instabilities, material behavior at extreme pressures, and optical and x-ray diagnostics for laser-heated targets. A suite of laser and target diagnostics are fielded on the Nike facility, including high-speed, high-resolution x-ray and visible imaging cameras, spectrometers and photo-detectors. A centrally-controlled, distributed computerized data acquisition system provides robust data management and near real-time analysis feedback capability during target shots. Work supported by DOE/NNSA.

  3. View of first level from east looking at the central ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    View of first level from east looking at the central bay. Interstitial structure is in the foreground center, main structure is in background left and right of view. - Marshall Space Flight Center, Saturn V Dynamic Test Facility, East Test Area, Huntsville, Madison County, AL

  4. jsc2017e136942 - In the town of Baikonur, Kazakhstan, Expedition 54-55 backup crewmembers Jeanette Epps of NASA, Sergey Prokopyev of the Russian Federal Space Agency (Roscosmos) and Alexander Gerst of the European Space Agency lay flowers Dec. 6 at the sta

    NASA Image and Video Library

    2017-12-06

    jsc2017e136942 - In the town of Baikonur, Kazakhstan, Expedition 54-55 backup crewmembers Jeanette Epps of NASA, Sergey Prokopyev of the Russian Federal Space Agency (Roscosmos) and Alexander Gerst of the European Space Agency lay flowers Dec. 6 at the sta

  5. jsc2017e136944 - In the town of Baikonur, Kazakhstan, Expedition 54-55 backup crewmembers Jeanette Epps of NASA, Sergey Prokopyev of the Russian Federal Space Agency (Roscosmos) and Alexander Gerst of the European Space Agency lay flowers Dec. 6 at the sta

    NASA Image and Video Library

    2017-12-06

    jsc2017e136944 - In the town of Baikonur, Kazakhstan, Expedition 54-55 backup crewmembers Jeanette Epps of NASA, Sergey Prokopyev of the Russian Federal Space Agency (Roscosmos) and Alexander Gerst of the European Space Agency lay flowers Dec. 6 at the sta

  6. Application analysis of solar total energy systems to the residential sector. Volume III, conceptual design. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1979-07-01

    The objective of the work described in this volume was to conceptualize suitable designs for solar total energy systems for the following residential market segments: single-family detached homes, single-family attached units (townhouses), low-rise apartments, and high-rise apartments. Conceptual designs for the total energy systems are based on parabolic trough collectors in conjunction with a 100 kWe organic Rankine cycle heat engine or a flat-plate, water-cooled photovoltaic array. The ORC-based systems are designed to operate as either independent (stand alone) systems that burn fossil fuel for backup electricity or as systems that purchase electricity from a utility grid for electrical backup.more » The ORC designs are classified as (1) a high temperature system designed to operate at 600/sup 0/F and (2) a low temperature system designed to operate at 300/sup 0/F. The 600/sup 0/F ORC system that purchases grid electricity as backup utilizes the thermal tracking principle and the 300/sup 0/F ORC system tracks the combined thermal and electrical loads. Reject heat from the condenser supplies thermal energy for heating and cooling. All of the ORC systems utilize fossil fuel boilers to supply backup thermal energy to both the primary (electrical generating) cycle and the secondary (thermal) cycle. Space heating is supplied by a central hot water (hydronic) system and a central absorption chiller supplies the space cooling loads. A central hot water system supplies domestic hot water. The photovoltaic system uses a central electrical vapor compression air conditioning system for space cooling, with space heating and domestic hot water provided by reject heat from the water-cooled array. All of the systems incorporate low temperature thermal storage (based on water as the storage medium) and lead--acid battery storage for electricity; in addition, the 600/sup 0/F ORC system uses a therminol-rock high temperature storage for the primary cycle. (WHK)« less

  7. Introduction to the LaRC central scientific computing complex

    NASA Technical Reports Server (NTRS)

    Shoosmith, John N.

    1993-01-01

    The computers and associated equipment that make up the Central Scientific Computing Complex of the Langley Research Center are briefly described. The electronic networks that provide access to the various components of the complex and a number of areas that can be used by Langley and contractors staff for special applications (scientific visualization, image processing, software engineering, and grid generation) are also described. Flight simulation facilities that use the central computers are described. Management of the complex, procedures for its use, and available services and resources are discussed. This document is intended for new users of the complex, for current users who wish to keep appraised of changes, and for visitors who need to understand the role of central scientific computers at Langley.

  8. Drug-nutrient interactions in three long-term-care facilities.

    PubMed

    Lewis, C W; Frongillo, E A; Roe, D A

    1995-03-01

    To assess the risk of drug-nutrient interactions (DNIs) in three long-term-care facilities. Retrospective audit of charts. Three long-term-care facilities in central New York State. Fifty-three patients selected randomly from each facility. Data were collected from the medical record of each patient for a period of 6 months. A computerized algorithm was used to assess the risk for DNIs. Mean drug use, most frequently consumed drugs, incidence of potential DNIs, and the most commonly observed potential DNIs are reported. In facilities A, B, and C, respectively, patients consumed a mean of 4.86, 4.04, and 5.27 drugs per patient per month and were at risk for a mean of 1.43, 2.69, and 1.43 potential DNIs per patient per month. The most commonly observed potential DNIs were gastrointestinal interactions affecting drug bioavailability and interactions affecting electrolyte status. Patients in long-term-care facilities, who are primarily elderly and chronically ill and who consume multiple medications, are at notable risk for certain DNIs. Efforts need to be made to ensure appropriate pharmacologic and nutrition therapies as well as adequate and timely monitoring of patients in these facilities. Dietitians can play an important role in training other health professionals and in designing policies to prevent DNIs.

  9. Human RECQL5: guarding the crossroads of DNA replication and transcription and providing backup capability.

    PubMed

    Popuri, Venkateswarlu; Tadokoro, Takashi; Croteau, Deborah L; Bohr, Vilhelm A

    2013-01-01

    DNA helicases are ubiquitous enzymes that catalyze unwinding of duplex DNA and function in all metabolic processes in which access to single-stranded DNA is required, including DNA replication, repair, recombination and RNA transcription. RecQ helicases are a conserved family of DNA helicases that display highly specialized and vital roles in the maintenance of genome stability. Mutations in three of the five human RecQ helicases, BLM, WRN and RECQL4 are associated with the genetic disorders Bloom syndrome, Werner syndrome and Rothmund-Thomson syndrome that are characterized by chromosomal instability, premature aging and predisposition to cancer. The biological role of human RECQL5 is only partially understood and RECQL5 has not yet been associated with any human disease. Illegitimate recombination and replication stress are hallmarks of human cancers and common instigators for genomic instability and cell death. Recql5 knockout mice are cancer prone and show increased chromosomal instability. Recql5-deficient mouse embryonic fibroblasts are sensitive to camptothecin and display elevated levels of sister chromatid exchanges. Unlike other human RecQ helicases, RECQL5 is recruited to single-stranded DNA breaks and is also proposed to play an essential role in RNA transcription. Here, we review the established roles of RECQL5 at the cross roads of DNA replication, recombination and transcription, and propose that human RECQL5 provides important backup functions in the absence of other DNA helicases.

  10. Family planning utilization and factors associated among women receiving abortion services in health facilities of central zone towns of Tigray, Northern Ethiopia: a cross sectional Study.

    PubMed

    Hagos, Goshu; Tura, Gurmesa; Kahsay, Gizienesh; Haile, Kebede; Grum, Teklit; Araya, Tsige

    2018-06-05

    Abortion remains among the leading causes of maternal death worldwide. Post-abortion contraception is significantly effective in preventing unintended pregnancy and abortion if provided before women leave the health facilty. However, the status of post-abortion family planning (PAFP) utilization and the contributing factors are not well studied in Tigray region. So, we conduct study aimed on family planning utilization and factors associated with it among women receiving abortion services. A facility based cross-sectional study design was conducted among women receiving abortion services in central zone of Tigray from December 2015to February 2016 using a total of 416 sample size. Women who came for abortion services were selected using systematic random sampling technique.. The data were collected using a pre-tested interviewer administered questionnair. Data were coded and entered in to Epi info 7 and then exported to SPSS for analysis. Descriptive statisticslike frequencies and mean were computed to display the results. Both Bivariable and multivariable logistic regression was used in the analysis. Variables statistically significant at p < 0.05 in the bivariable analysis were checked in multivariable logistic regration to identify independently associated factors. Then variables which were significantly associated with post abortion family planning utilization at p-value < 0.05 in the multivariable analysis were declared as significantly associated factors. A total of 409 abortion clients were interviewed in this study with 98.3% of response rate. Majority 290 (70.9%) of study participants utilized contracepives after abortion. Type of health facility, the decision maker on timing of having child, knowledge that pregnancy can happen soon after abortion and husband's opposition towards contraceptives were significantly associated with Post-abortion family planning ustilization. About one-third of abortion women failed to receive contraceptive before

  11. Experiment/facility requirements document for the Space Station Furnace Facility. Section 1: Integrated configuration

    NASA Astrophysics Data System (ADS)

    1992-05-01

    The function of the Space Station Furnace Facility (SSFF) is to support materials research into the crystal growth and solidification processes of electronic and photonic materials, metals and alloys, and glasses and ceramics. To support this broad base of research requirements, the SSFF will employ a variety of furnace modules which will be operated, regulated, and supported by a core of common subsystems. Furnace modules may be reconfigured or specifically developed to provide unique solidification conditions for each set of experiments. The SSFF modular approach permits the addition of new or scaled-up furnace modules to support the evolution of the facility as new science requirements are identified. The SSFF Core is of modular design to permit augmentation for enhanced capabilities. The fully integrated configuration of the SSFF will consist of three racks with the capability of supporting up to two furnace modules per rack. The initial configuration of the SSFF will consist of two of the three racks and one furnace module. This Experiment/Facility Requirements Document (E/FRD) describes the integrated facility requirements for the Space Station Freedom (SSF) Integrated Configuration-1 (IC1) mission. The IC1 SSFF will consist of two racks: the Core Rack, with the centralized subsystem equipment; and the Experiment Rack-1, with Furnace Module-1 and the distributed subsystem equipment to support the furnace. The SSFF support functions are provided by the following Core subsystems: power conditioning and distribution subsystem (SSFF PCDS); data management subsystem (SSFF DMS); thermal control Subsystem (SSFF TCS); gas distribution subsystem (SSFF GDS); and mechanical structures subsystem (SSFF MSS).

  12. Experiment/facility requirements document for the Space Station Furnace Facility. Section 1: Integrated configuration

    NASA Technical Reports Server (NTRS)

    1992-01-01

    The function of the Space Station Furnace Facility (SSFF) is to support materials research into the crystal growth and solidification processes of electronic and photonic materials, metals and alloys, and glasses and ceramics. To support this broad base of research requirements, the SSFF will employ a variety of furnace modules which will be operated, regulated, and supported by a core of common subsystems. Furnace modules may be reconfigured or specifically developed to provide unique solidification conditions for each set of experiments. The SSFF modular approach permits the addition of new or scaled-up furnace modules to support the evolution of the facility as new science requirements are identified. The SSFF Core is of modular design to permit augmentation for enhanced capabilities. The fully integrated configuration of the SSFF will consist of three racks with the capability of supporting up to two furnace modules per rack. The initial configuration of the SSFF will consist of two of the three racks and one furnace module. This Experiment/Facility Requirements Document (E/FRD) describes the integrated facility requirements for the Space Station Freedom (SSF) Integrated Configuration-1 (IC1) mission. The IC1 SSFF will consist of two racks: the Core Rack, with the centralized subsystem equipment; and the Experiment Rack-1, with Furnace Module-1 and the distributed subsystem equipment to support the furnace. The SSFF support functions are provided by the following Core subsystems: power conditioning and distribution subsystem (SSFF PCDS); data management subsystem (SSFF DMS); thermal control Subsystem (SSFF TCS); gas distribution subsystem (SSFF GDS); and mechanical structures subsystem (SSFF MSS).

  13. Conceptual design report: Nuclear materials storage facility renovation. Part 6, Alternatives study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1995-07-14

    The Nuclear Materials Storage Facility (NMSF) at the Los Alamos National Laboratory (LANL) was a Fiscal Year (FY) 1984 line-item project completed in 1987 that has never been operated because of major design and construction deficiencies. This renovation project, which will correct those deficiencies and allow operation of the facility, is proposed as an FY 97 line item. The mission of the project is to provide centralized intermediate and long-term storage of special nuclear materials (SNM) associated with defined LANL programmatic missions and to establish a centralized SNM shipping and receiving location for Technical Area (TA)-55 at LANL. Based onmore » current projections, existing storage space for SNM at other locations at LANL will be loaded to capacity by approximately 2002. This will adversely affect LANUs ability to meet its mission requirements in the future. The affected missions include LANL`s weapons research, development, and testing (WRD&T) program; special materials recovery; stockpile survelliance/evaluation; advanced fuels and heat sources development and production; and safe, secure storage of existing nuclear materials inventories. The problem is further exacerbated by LANL`s inability to ship any materials offsite because of the lack of receiver sites for material and regulatory issues. Correction of the current deficiencies and enhancement of the facility will provide centralized storage close to a nuclear materials processing facility. The project will enable long-term, cost-effective storage in a secure environment with reduced radiation exposure to workers, and eliminate potential exposures to the public. This report is organized according to the sections and subsections outlined by Attachment 111-2 of DOE Document AL 4700.1, Project Management System. It is organized into seven parts. This document, Part VI - Alternatives Study, presents a study of the different storage/containment options considered for NMSF.« less

  14. Oil Pharmacy at the Thermal Protection System Facility

    NASA Image and Video Library

    2017-08-08

    An overall view of the Oil Pharmacy operated under the Test and Operations Support Contract, or TOSC. The facility consolidated storage and distribution of petroleum products used in equipment maintained under the contract. This included standardized naming, testing processes and provided a central location for distribution of oils used in everything from simple machinery to the crawler-transporter and cranes in the Vehicle Assembly Building.

  15. Indoor Lighting Facilities

    NASA Astrophysics Data System (ADS)

    Matsushima, Koji; Saito, Yoshinori; Ichikawa, Shigenori; Kawauchi, Takao; Tanaka, Tsuneo; Hirano, Rika; Tazuke, Fuyuki

    According to the statistics by the Ministry of Land, Infrastructure and Transport, the total floor space of all building construction started was 188.87 million m2 (1.5% increase y/y), marking the fourth straight year of increase. Many large-scale buildings under construction in central Tokyo become fully occupied by tenants before completion. As for office buildings, it is required to develop comfortable and functional office spaces as working styles are becoming more and more diversified, and lighting is also an element of such functionalities. The total floor space of construction started for exhibition pavilions, multipurpose halls, conference halls and religious architectures decreased 11.1% against the previous year. This marked a decline for 10 consecutive years and the downward trend continues. In exhibition pavilions, the light radiation is measured and adjusted throughout the year so as not to damage the artworks by lighting. Hospitals, while providing higher quality medical services and enhancing the dwelling environment of patients, are expected to meet various restrictions and requirements, including the respect for privacy. Meanwhile, lighting designs for school classrooms tend to be homogeneous, yet new ideas are being promoted to strike a balance between the economical and functional aspects. The severe economic environment continues to be hampering the growth of theaters and halls in both the private and public sectors. Contrary to the downsizing trend of such facilities, additional installations of lighting equipment were conspicuous, and the adoption of high efficacy lighting appliances and intelligent function control circuits are becoming popular. In the category of stores/commercial facilities, the construction of complex facilities is a continuing trend. Indirect lighting, high luminance discharge lamps with excellent color rendition and LEDs are being effectively used in these facilities, together with the introduction of lighting designs

  16. jsc2017e138127 - At the Baikonur Cosmodrome in Kazakhstan, the Expedition 54-55 prime and backup crewmembers pose for pictures Dec. 13 in front of the cottage where the iconic Russian space designer Sergey Korolev slept on the night before Yuri Gagarin la

    NASA Image and Video Library

    2017-12-13

    jsc2017e138127 - At the Baikonur Cosmodrome in Kazakhstan, the Expedition 54-55 prime and backup crewmembers pose for pictures Dec. 13 in front of the cottage where the iconic Russian space designer Sergey Korolev slept on the night before Yuri Gagarin launched April 12, 1961 to become the first human to fly in space. Korolev’s cottage is next to the cottage where Gagarin slept on the eve of his launch. From left to right are backup crewmembers Alexander Gerst of the European Space Agency, Sergey Prokopyev of the Russian Federal Space Agency (Roscosmos) and Jeanette Epps of NASA, and prime crewmembers Scott Tingle of NASA, Anton Shkaplerov of Roscosmos and Norishige Kanai of the Japan Aerospace Exploration Agency. Tingle, Kanai and Shkaplerov will launch Dec. 17 on the Soyuz MS-07 spacecraft for a five month mission on the International Space Station...Andrey Shelepin/Gagarin Cosmonaut Training Center.

  17. Clarke Central High School: One Student at a Time

    ERIC Educational Resources Information Center

    Principal Leadership, 2013

    2013-01-01

    There is excitement in the air at Clarke Central High School in anticipation of a $28 million renovation planned on its 27-acre, urban campus located just minutes from the University of Georgia in Athens. This extensive construction aims to fulfill a board of education mandate to provide equity among the Clarke County school facilities and will…

  18. This image, looking due south shows the central part of ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    This image, looking due south shows the central part of the north wing of the building, a 2 story facade. In the foreground are several utility chases which span this elevation of the building - Department of Energy, Mound Facility, Electronics Laboratory Building (E Building), One Mound Road, Miamisburg, Montgomery County, OH

  19. Preparedness of elderly long-term care facilities in HSE East for influenza outbreaks.

    PubMed

    O'Connor, L; Boland, M; Murphy, H

    2015-01-01

    Abstract We assessed preparedness of HSE East elderly long-term care facilities for an influenza outbreak, and identified Public Health Department support needs. We surveyed 166 facilities based on the HSE checklist document for influenza outbreaks, with 58% response rate. Client flu vaccination rates were > 75%; leading barriers were client anxiety and consent issues. Target flu vaccine uptake of 40% in staff occurred in 43% of facilities and was associated with staff vaccine administration by afacility-attached GP (p = 0.035), having a facility outbreak plan (p = 0.013) and being anon-HSE run facility (p = 0.013). Leading barriers were staff personal anxiety (94%) and lack of awareness of the protective effect on clients (21%). Eighty-nine percent found Public Health helpful, and requested further educational support and advocacy. Staff vaccine uptake focus, organisational leadership, optimal vaccine provision models, outbreak plans and Public Health support are central to the influenza campaign in elderly long-term care facilities.

  20. jsc2017e136939 - At the Cosmonaut Hotel crew quarters in Baikonur, Kazakhstan, the Expedition 54-55 backup crewmembers take a stroll down the Walk of Cosmonauts Dec. 6 to lay flowers in traditional pre-launch ceremonies. From left to right are Jeanette Epp

    NASA Image and Video Library

    2017-12-06

    jsc2017e136939 - At the Cosmonaut Hotel crew quarters in Baikonur, Kazakhstan, the Expedition 54-55 backup crewmembers take a stroll down the Walk of Cosmonauts Dec. 6 to lay flowers in traditional pre-launch ceremonies. From left to right are Jeanette Epp

  1. 23. BUILDING NO. 452, ORDNANCE FACILITY (BAG CHARGE FILLING PLANT), ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    23. BUILDING NO. 452, ORDNANCE FACILITY (BAG CHARGE FILLING PLANT), INTERIOR, LOOKING SOUTH DOWN CENTRAL CORRIDOR. NOTE BINS IN WALLS ON EITHER SIDE OF CORRIDOR, USED FOR PASSING EXPLOSIVES AND LOADED ITEMS TO SIEVING ROOMS BEYOND WALLS. - Picatinny Arsenal, 400 Area, Gun Bag Loading District, State Route 15 near I-80, Dover, Morris County, NJ

  2. Facility Planning for 21st Century. Technology, Industry, and Education.

    ERIC Educational Resources Information Center

    Hill, Franklin

    When the Orange County School Board (Orlando, Florida) decided to build a new high school, they recognized Central Florida's high technology emphasis as a special challenge. The new facility needed to meet present instructional demands while being flexible enough to incorporate 21st century technologies. The final result is a new $30 million high…

  3. Credit PSR. This view shows southeast and southwest facades as ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Credit PSR. This view shows southeast and southwest facades as seen when looking east northeast (70°). This steel frame building is clad in "Transite" board (fire- resistant, pressed asbestos composition board). This structure was built as a back-up to Building 4237/E-38, but no equipment was ever installed. It was equipped instead to conduct tensile tests on propellant samples. In 1984, it was converted into a back-up structure supporting Building 4283/E-84, Propellant Processing Building. Small amounts of HMX propellants were processed and dried here - Jet Propulsion Laboratory Edwards Facility, Oxidizer Dryer Blender Building, Edwards Air Force Base, Boron, Kern County, CA

  4. BRUCELLOSIS IN TEREKEKA COUNTY, CENTRAL EQUATORIA STATE, SOUTHERN SUDAN.

    PubMed

    Lado, D; Maina, N; Lado, M; Abade, A; Amwayi, S; Omolo, J; Oundo, J

    2012-01-01

    To identify factors associated with Brucellosis in patients attending Terekeka Health Facility, Terekeka County, Central Equatoria State, Southern Sudan and to evaluate the utility of the rapid test kit Euracil®. A facility based case-control study. Terekeka Health Facility, Terekeka County, Central Equatoria State, Southern Sudan. Cases were patients presenting at the Terekeka Health Facility with clinical symptoms suggestive of Brucellosis and tested positive for Brucellosis by rapid antigen test while controls were selected from individuals attending Terekeka Health facility with health problems unrelated to brucellosis or febrile illness. A total of fifty eight cases with clinical symptoms suggestive of and tested positive for Brucellosis by rapid antigen test presented. A total of 116 consented controls were recruited into the study. Males accounted for 52% of the cases and 53% of the controls. The mean age was 31 years for both groups. Cases without formal education were 84% while 40% had no source of income, 20% of the cases and 14% of the controls were cattle keepers while 5% of the cases and 13% of the controls were students. In multivariate analysis there were many factors associated with Brucellosis like consumption of raw meat, living with animals at the same place, raising of goats, farm cleaning contact, eating of aborted and wild animals. Logistic regression revealed two factors associated with the disease; consumption of raw milk (OR=3.9, P-value 0.001, 95% CI 1.6666-9.0700) was a risk factor while drinking boiled milk was protective (OR = 0.09, p-value 0.000, 95% CI, 0.1-0.2). The main age-groups affected were 20-30 years with males being affected more than females. Drinking of raw milk was significantly associated with Brucellosis while drinking boiled milk was protective. There should be active public health education on the benefits of boiling milk before consumption. Further studies to elucidate the extent and epidemiology of brucellosis in

  5. Reasons for Discontinuing Hashish Use in a Group of Central European Athletes.

    ERIC Educational Resources Information Center

    Duncan, David F.

    1988-01-01

    Examined self-reported reasons for discontinuing marijuana use among 61 former marijuana using students at central European sports training facility. Most common reasons given for discontinuing marijuana use were dislike of effects, athletic training regimen, health reasons, and mental/emotional problems. (Author/NB)

  6. Jonathan W. Amy and the Amy Facility for Instrumentation Development.

    PubMed

    Cooks, R Graham

    2017-05-16

    This Perspective describes the unique Jonathan Amy Facility for Chemical Instrumentation in the Department of Chemistry at Purdue University, tracing its history and mode of operation. It also describes aspects of the career of its namesake and some of his insights which have been central to analytical instrumentation development, improvement, and utilization, both at Purdue and nationally.

  7. PORTRAIT - PRIME AND BACKUP CREWS - ASTRONAUT EDWARD H. WHITE II

    NASA Image and Video Library

    1966-04-01

    S66-30236 (1 April 1966) --- The National Aeronautics and Space Administration (NASA) has named these astronauts as the prime crew of the first manned Apollo Space Flight. Left to right, are Edward H. White II, command module pilot; Virgil I. Grissom, mission commander; and Roger B. Chaffee, lunar module pilot. Editor's Note: Astronauts Grissom, White and Chaffee lost their lives in a Jan. 27, 1967 fire in the Apollo Command Module (CM) during testing at the launch facility.

  8. Oil Pharmacy at the Thermal Protection System Facility

    NASA Image and Video Library

    2017-08-08

    Tim King of Jacobs at NASA's Kennedy Space Center in Florida, explains operations in the Oil Pharmacy operated under the Test and Operations Support Contract, or TOSC. The facility consolidated storage and distribution of petroleum products used in equipment maintained under the contract. This included standardized naming, testing processes and provided a central location for distribution of oils used in everything from simple machinery to the crawler-transporter and cranes in the Vehicle Assembly Building.

  9. Centralized Fabric Management Using Puppet, Git, and GLPI

    NASA Astrophysics Data System (ADS)

    Smith, Jason A.; De Stefano, John S., Jr.; Fetzko, John; Hollowell, Christopher; Ito, Hironori; Karasawa, Mizuki; Pryor, James; Rao, Tejas; Strecker-Kellogg, William

    2012-12-01

    Managing the infrastructure of a large and complex data center can be extremely difficult without taking advantage of recent technological advances in administrative automation. Puppet is a seasoned open-source tool that is designed for enterprise class centralized configuration management. At the RHIC and ATLAS Computing Facility (RACF) at Brookhaven National Laboratory, we use Puppet along with Git, GLPI, and some custom scripts as part of our centralized configuration management system. In this paper, we discuss how we use these tools for centralized configuration management of our servers and services, change management requiring authorized approval of production changes, a complete version controlled history of all changes made, separation of production, testing and development systems using puppet environments, semi-automated server inventory using GLPI, and configuration change monitoring and reporting using the Puppet dashboard. We will also discuss scalability and performance results from using these tools on a 2,000+ node cluster and 400+ infrastructure servers with an administrative staff of approximately 25 full-time employees (FTEs).

  10. Analysis of Disaster Preparedness Planning Measures in DoD Computer Facilities

    DTIC Science & Technology

    1993-09-01

    city, stae, aod ZP code) 10 Source of Funding Numbers SProgram Element No lProject No ITask No lWork Unit Accesion I 11 Title include security...Computer Disaster Recovery .... 13 a. PC and LAN Lessons Learned . . ..... 13 2. Distributed Architectures . . . .. . 14 3. Backups...amount of expense, but no client problems." (Leeke, 1993, p. 8) 2. Distributed Architectures The majority of operations that were disrupted by the

  11. Evolution in a centralized transfusion service.

    PubMed

    AuBuchon, James P; Linauts, Sandra; Vaughan, Mimi; Wagner, Jeffrey; Delaney, Meghan; Nester, Theresa

    2011-12-01

    The metropolitan Seattle area has utilized a centralized transfusion service model throughout the modern era of blood banking. This approach has used four laboratories to serve over 20 hospitals and clinics, providing greater capabilities for all at a lower consumption of resources than if each depended on its own laboratory and staff for these functions. In addition, this centralized model has facilitated wider use of the medical capabilities of the blood center's physicians, and a county-wide network of transfusion safety officers is now being developed to increase the impact of the blood center's transfusion expertise at the patient's bedside. Medical expectations and traffic have led the blood center to evolve the centralized model to include on-site laboratories at facilities with complex transfusion requirements (e.g., a children's hospital) and to implement in all the others a system of remote allocation. This new capability places a refrigerator stocked with uncrossmatched units in the hospital but retains control over the dispensing of these through the blood center's computer system; the correct unit can be electronically cross-matched and released on demand, obviating the need for transportation to the hospital and thus speeding transfusion. This centralized transfusion model has withstood the test of time and continues to evolve to meet new situations and ensure optimal patient care. © 2011 American Association of Blood Banks.

  12. Downgrading Nuclear Facilities to Radiological Facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jarry, Jeffrey F.; Farr, Jesse Oscar; Duran, Leroy

    2015-08-01

    Based on inventory reductions and the use of alternate storage facilities, the Sandia National Laboratories (SNL) downgraded 4 SNL Hazard Category 3 (HC-3) nuclear facilities to less-than-HC-3 radiological facilities. SNL’s Waste Management and Pollution Prevention Department (WMPPD) managed the HC-3 nuclear facilities and implemented the downgrade. This paper will examine the downgrade process,

  13. Central Campus Construction Progress

    NASA Image and Video Library

    2017-03-17

    NASA's Kennedy Space Center in Florida is a premier, multi-user spaceport with ongoing construction adding new, ultra-modern facilities. A key element of the Central Campus makeover is a new, seven-story, 200,000-square-foot headquarters building that has taken shape in the heart of the spaceport. The headquarters building's glass facade, as seen from NASA Causeway, is complete. The exterior skin of the building also is nearly finished. The remainder of the glass components are being installed on each floor. Construction of interior walls and utilities on most floors is well underway. Construction of the headquarters building is targeted for completion in November 2017 and employees are expected to be able to move in soon after.

  14. An Analysis of Medical Imaging Costs in Military Treatment Facilities

    DTIC Science & Technology

    2014-09-01

    authority to completely control the medical systems of each service, the DHA 7 was given management responsibility for specific shared services , functions...efficient health operations through enhanced enterprise-wide shared services . • Deliver more comprehensive primary care and integrated health...of shared services that will fall under central control: • facility planning • medical logistics • health information technology • Tricare health

  15. Glycogen function in adult central and peripheral nerves.

    PubMed

    Evans, Richard D; Brown, Angus M; Ransom, Bruce R

    2013-08-01

    We studied the roles of glycogen in axonal pathways of the central nervous system (CNS) and peripheral nervous system (PNS). By using electrophysiological recordings, in combination with biochemical glycogen assay, it was possible to determine whether glycogen was crucial to axon function under different conditions. Glycogen was present both in mouse optic nerve (MON) and in mouse sciatic nerve (MSN). Aglycemia caused loss of the compound action potential (CAP) in both pathways after a latency of 15 min (MON) and 120 min for myelinated axons (A fibers) in the MSN. With the exception of unmyelinated axons (C fibers) in the MSN, CAP decline began when usable glycogen was exhausted. Glycogen was located in astrocytes in the MON and in myelinating Schwann cells in the MSN; it was absent from the Schwann cells surrounding unmyelinated C fibers. In MON, astrocytic glycogen is metabolized to lactate and "shuttled" to axons to support metabolism. The ability of lactate to support A fiber conduction in the absence of glucose suggests a common pathway in both the CNS and the PNS. Lactate is released from MON and MSN in substantial quantities. That lactate levels fall in MSN in the presence of diaminobenzidine, which inhibits glycogen phosphorylase, strongly suggests that glycogen metabolism contributes to lactate release under resting conditions. Glycogen is a "backup" energy substrate in both the CNS and the PNS and, beyond sustaining excitability during glucose deprivation, has the capacity to subsidize the axonal energy demands during times of intense activity in the presence of glucose. Copyright © 2013 Wiley Periodicals, Inc.

  16. KENNEDY SPACE CENTER, FLA. - NASA Administrator Sean O’Keefe (center) listens to Congressman Tom Feeney (second from left) during a tour of the Central Florida Research Park, near Orlando. At right is U.S. Congressman Dave Weldon. Central Florida leaders are proposing the research park as the site for the new NASA Shared Services Center. The center would centralize NASA’s payroll, accounting, human resources, facilities and procurement offices that are now handled at each field center. The consolidation is part of the One NASA focus. Six sites around the U.S. are under consideration by NASA.

    NASA Image and Video Library

    2004-02-19

    KENNEDY SPACE CENTER, FLA. - NASA Administrator Sean O’Keefe (center) listens to Congressman Tom Feeney (second from left) during a tour of the Central Florida Research Park, near Orlando. At right is U.S. Congressman Dave Weldon. Central Florida leaders are proposing the research park as the site for the new NASA Shared Services Center. The center would centralize NASA’s payroll, accounting, human resources, facilities and procurement offices that are now handled at each field center. The consolidation is part of the One NASA focus. Six sites around the U.S. are under consideration by NASA.

  17. KENNEDY SPACE CENTER, FLA. - - U.S. Representative Ric Keller (left) listens intently to a presentation proposing the use of the Central Florida Research Park, near Orlando, as the site of NASA’s new Shared Services Center. NASA and Florida officials toured the research park as well. Central Florida leaders are proposing the research park as the site for the center, which would centralize NASA’s payroll, accounting, human resources, facilities and procurement offices that are now handled at each field center. The consolidation is part of the One NASA focus. Six sites around the U.S. are under consideration by NASA.

    NASA Image and Video Library

    2004-02-19

    KENNEDY SPACE CENTER, FLA. - - U.S. Representative Ric Keller (left) listens intently to a presentation proposing the use of the Central Florida Research Park, near Orlando, as the site of NASA’s new Shared Services Center. NASA and Florida officials toured the research park as well. Central Florida leaders are proposing the research park as the site for the center, which would centralize NASA’s payroll, accounting, human resources, facilities and procurement offices that are now handled at each field center. The consolidation is part of the One NASA focus. Six sites around the U.S. are under consideration by NASA.

  18. [The challenges of sustainable development in healthcare facilities].

    PubMed

    Mourgues, François; Muret, Jane; Pauchard, Jean-Claude

    2018-03-01

    Healthcare and medical-social facilities have a major responsibility within society, that of the quality of care, but also that of developing a system of sustainable and socially-responsible health. This system must meet the three pillars which constitute such an approach: economic, social and environmental sustainability. Innovation remains central to the sustainable evolution of practices and the first results are now visible. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  19. MicroPPT-Based Secondary/Backup ACS for a 160-m, 450-kg Solar Sail Spacecraft

    NASA Technical Reports Server (NTRS)

    Wie, Bong; Murphy, David

    2005-01-01

    Solar sail tip-mounted, lightweight pulsed plasma thrusters (PPTs) are proposed for a secondary (or backup) attitude control system (ACS) of a 160-m, 450-kg solar sail spacecraft of the Solar Polar Imager (SPI) mission. A propellantless primary ACS of the SPI sailcraft employs trim control masses running along mast lanyards for pitch/yaw control together with roll stabilizer bars at the mast tips for quadrant tilt (roll) control. The robustness of such a propellantless primary ACS would be further enhanced by a secondary ACS utilizing tip-mounted, lightweight PPTs. The microPPT-based ACS is intended mainly for attitude recovery maneuvers from various off-nominal conditions that cannot be reliably handled by the propellantless primary ACS. However, it can also be employed for: i) the checkout or standby mode prior to and during sail deployment, ii) the post-deployment transition mode (prior to the propellantless primary ACS mode operation), iii) the solar sailing cruise mode of a trimmed sailcraft, and iv) the spin-stabilized, sun-pointing, safe mode. Although a conventional bus ACS is required for the SPI mission as the sail is jettisoned at the start of its science mission phase, the microPPT-based ACS option promises greater redundancy and robustness for the SPI mission. For other sailing missions, where the sail is never jettisoned, this secondary ACS provides a lower-cost, lower-mass propulsion for deployment control and greater redundancy than any traditional reaction-jet control system. This paper presents an overview nf the state--of-the--art microPPT technology, the design requirements of microPPTs for solar sail attitude control, and the preliminary ACS design and simulation results.

  20. Operation and maintenance of the Sol-Dance Building solar system. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gaultney, J.R.

    1980-07-29

    A 16,400 square foot general office facility has its primary heating provided by a flat plate solar system using hydronic storage and water-to-air transfer coils for distribution. Backup heat is provided by 10 individually controlled air source heat pumps ranging from 3 tons to 5 tons in capacity. These heat pumps also contain electric resistive elements for use during extremely low ambient temperatures. Cooling is also provided by the heat pumps. Each of the two buildings contains a separate domestic hot water system. Primary heat is provided by a closed loop solar unit with electric elements providing backup heat. Amore » 10,000 gallon black steel water tank provides heat storage.« less

  1. The Challenge of Caring for Mildly Ill Children: A Canadian National Childcare Study

    ERIC Educational Resources Information Center

    Polyzoi, E.; Babb, J.C.

    2004-01-01

    This Canadian study of the care of mildly ill children in licensed childcare facilities compares director and parent preferences for eight models of care, exclusionary practices for ill children by directors, and preferred backup care options of parents. It also investigates anticipated usage and willingness of parents to pay for emergency…

  2. Economic analysis of effluent limitation guidelines and standards for the centralized waste treatment industry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wheeler, W.

    1998-12-01

    This report estimates the economic and financial effects and the benefits of compliance with the proposed effluent limitations guidelines and standards for the Centralized Waste Treatment (CWT) industry. The Environmental Protection Agency (EPA) has measured these impacts in terms of changes in the profitability of waste treatment operations at CWT facilities, changes in market prices to CWT services, and changes in the quantities of waste management at CWT facilities in six geographic regions. EPA has also examined the impacts on companies owning CWT facilities (including impacts on small entities), on communities in which CWT facilities are located, and on environmentalmore » justice. EPA examined the benefits to society of the CWT effluent limitations guidelines and standards by examining cancer and non-cancer health effects of the regulation, recreational benefits, and cost savings to publicly owned treatment works (POTWs) to which indirect-discharging CWT facilities send their wastewater.« less

  3. Initial utilization of the CVIRB video production facility

    NASA Technical Reports Server (NTRS)

    Parrish, Russell V.; Busquets, Anthony M.; Hogge, Thomas W.

    1987-01-01

    Video disk technology is one of the central themes of a technology demonstrator workstation being assembled as a man/machine interface for the Space Station Data Management Test Bed at Johnson Space Center. Langley Research Center personnel involved in the conception and implementation of this workstation have assembled a video production facility to allow production of video disk material for this propose. This paper documents the initial familiarization efforts in the field of video production for those personnel and that facility. Although the entire video disk production cycle was not operational for this initial effort, the production of a simulated disk on video tape did acquaint the personnel with the processes involved and with the operation of the hardware. Invaluable experience in storyboarding, script writing, audio and video recording, and audio and video editing was gained in the production process.

  4. 24. BUILDING NO. 452, ORDNANCE FACILITY (BAG CHARGE FILLING PLANT), ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    24. BUILDING NO. 452, ORDNANCE FACILITY (BAG CHARGE FILLING PLANT), INTERIOR VIEW LOOKING WEST AT NORTH END OF CENTRAL CORRIDOR (ROOM 3). STAIRWAY WORKBENCH WITH COMPRESSED-AIR POWERED CARTRIDGE LOADER. ARMORED PASS-THROUGH OF TRANSFER BOX FOR PASSING EXPLOSIVES MATERIALS THROUGH TO NEXT ROOM TO THE NORTH. - Picatinny Arsenal, 400 Area, Gun Bag Loading District, State Route 15 near I-80, Dover, Morris County, NJ

  5. Determinants of anemia among pregnant mothers attending antenatal care in Dessie town health facilities, northern central Ethiopia, unmatched case -control study.

    PubMed

    Tadesse, Sisay Eshete; Seid, Omer; G/Mariam, Yemane; Fekadu, Abel; Wasihun, Yitbarek; Endris, Kedir; Bitew, Abebayehu

    2017-01-01

    Anemia affects around 38.2% and 22% of pregnant women at a global and national level respectively. In developing countries, women start pregnancy with already depleted body stores of iron and other vitamins with significant variation of anemia within and between regions. To identify the determinants of anemia among pregnant mothers attending antenatal care in Dessie town health facilities, northern central Ethiopia. A health facility based unmatched case control study was conducted among 112 cases and 336 controls from January to March 2016 G.C. The sample size was determined by using Epi Info version 7.1.5.2. Study subjects were selected using consecutive sampling technique. Data were collected using a structured questionnaire, entered using Epi Data version 3.1 and analyzed using SPSS version 20. Bivariable and multivariable logistic regression model was used to see the determinants of anemia. Adjusted odds ratio (AOR) with 95% confidence interval (CI) and p-value<0.05 were used to see the significant association. Failure to take dark green leafy vegetables per two weeks (AOR = 5.02, 95% CI: 2.16, 11.71), didn't take chicken per two weeks (AOR = 2.68, 95% CI: 1.22, 5.86), 1st trimester (AOR = 2.07, 95% CI: 1.12, 3.84), 3rd trimester (AOR = 2.96, 95% CI: 1.53, 5.72), HIV infection (AOR = 6.78, 95% CI: 2.28, 20.18) and medication (AOR = 3.57 95% CI: 1.60, 7.98) were positively associated with anemia. Inadequate intake of dark green leafy vegetables, inadequate consumption of chicken, trimester of the current pregnancy, HIV infection and medication were the determinants of anemia among pregnant women. Therefore, anemia prevention strategy should include promotion of adequate intake of dark green leafy vegetables and chicken, increase meal pattern during the entire pregnancy and strengthen the prevention of mother to child HIV transmission/antenatal care programs.

  6. Determinants of anemia among pregnant mothers attending antenatal care in Dessie town health facilities, northern central Ethiopia, unmatched case -control study

    PubMed Central

    Seid, Omer; G/Mariam, Yemane; Fekadu, Abel; Wasihun, Yitbarek; Endris, Kedir; Bitew, Abebayehu

    2017-01-01

    Introduction Anemia affects around 38.2% and 22% of pregnant women at a global and national level respectively. In developing countries, women start pregnancy with already depleted body stores of iron and other vitamins with significant variation of anemia within and between regions. Objective To identify the determinants of anemia among pregnant mothers attending antenatal care in Dessie town health facilities, northern central Ethiopia. Methods A health facility based unmatched case control study was conducted among 112 cases and 336 controls from January to March 2016 G.C. The sample size was determined by using Epi Info version 7.1.5.2. Study subjects were selected using consecutive sampling technique. Data were collected using a structured questionnaire, entered using Epi Data version 3.1 and analyzed using SPSS version 20. Bivariable and multivariable logistic regression model was used to see the determinants of anemia. Adjusted odds ratio (AOR) with 95% confidence interval (CI) and p-value<0.05 were used to see the significant association. Results Failure to take dark green leafy vegetables per two weeks (AOR = 5.02, 95% CI: 2.16, 11.71), didn’t take chicken per two weeks (AOR = 2.68, 95% CI: 1.22, 5.86), 1st trimester (AOR = 2.07, 95% CI: 1.12, 3.84), 3rd trimester (AOR = 2.96, 95% CI: 1.53, 5.72), HIV infection (AOR = 6.78, 95% CI: 2.28, 20.18) and medication (AOR = 3.57 95% CI: 1.60, 7.98) were positively associated with anemia. Conclusions Inadequate intake of dark green leafy vegetables, inadequate consumption of chicken, trimester of the current pregnancy, HIV infection and medication were the determinants of anemia among pregnant women. Therefore, anemia prevention strategy should include promotion of adequate intake of dark green leafy vegetables and chicken, increase meal pattern during the entire pregnancy and strengthen the prevention of mother to child HIV transmission/antenatal care programs. PMID:28288159

  7. The global, centralized approach of the GAIN Premix Facility has made oil fortification in Indonesia more affordable.

    PubMed

    Jallier, Vincent; Guyondet, Christophe; Provent, Adeline; Laillou, Arnaud; Soekirman; Moench-Pfanner, Regina

    2013-06-01

    Access to high-grade micronutrients is a recurring challenge that often threatens the long-term sustainability of food fortification programs. To assess the efficiency of the Global Alliance for Improved Nutrition (GAIN) Premix Facility in procuring quality, affordable vitamin A for fortification of edible oil in Indonesia. A global approach to procurement of standard items was used by combining volumes across various demand streams in order to reduce the total cost of acquisition through economies of scale. The GAIN Premix Facility undertook a detailed analysis of vitamin A requirements across its existing customer base, which served as a basis for developing a reliable demand forecast. A consolidated, competitive tender was launched that resulted in the setting up of a long-term commercial agreement with the selected supplier to lock in the most competitive price for a given period of time. The direct benefit to oil manufacturers of fortifying with vitamin A is that the cost of fortification went down significantly compared with prices they would have been offered had they ordered vitamin A individually. In Indonesia, this consolidated procurement approach has allowed a 14.5% decrease in the unit price of vitamin A. The GAIN Premix Facility demonstrated its effectiveness in acting as a global procurement platform by aggregating demand across different customers and leveraging improved prices through increased volumes. Building on the success of this effort, the GAIN Premix Facility is replicating this global approach for procurement of other standard items being procured across fortification programs worldwide.

  8. Gunion - Nevada`s most innovative geothermal food dehydration facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Trexler, D.T.; Taylan, G.; Stewart, M.B.

    1995-12-31

    The Gunion (garlic and onion) dehydration plant, owned and operated by Integrated Ingredients, a Division of Burns Philp Food, Incorporated, uses geothermal fluids at a temperature of 306{degrees}F to dehydrate 50 to 70-thousand pounds per day of garlic and onions. The geothermal fluids are provided by Empire Farms, who has the rights for development of the resource and is the lease holder of fee land known as the Kosmos Lease. The San Emidio KGRA is located in northern Washoe County, 90 miles north-northeast of Reno, Nevada and 20 miles south of Gerlach, Nevada. Geothermal fluids exit the plant at 242{degrees}Fmore » and are piped to an injection well located 3,000 feet south-southwest of the plant. The plant location was selected not only for the geothermal resource, but also for the area`s low relative humidity. Currently, 1100-1200 gpm of geothermal fluids, at an inlet temperature of 302{degrees}F, are sufficient to provide the dryer line with ample BTU`s. Three geothermal wells drilled to depths ranging from 493 to 1817 feet produce fluids ranging in temperature from 266 to 306{degrees}F. One well can easily provide the heat required by the dryer line and will be capable of providing heat for a planned three-fold expansion of the facility. The remaining two wells are used as backup, or may be used for other applications such as soil sterilization. The fluid exiting the plant at 242{degrees}F may be cascaded and used for greenhouses and soil warming in the future. Geothermal heat is also used to dehumidify onions placed in the cold storage facility. The dehydration process takes 5-6 hours to dry the product to a 4.5% moisture content. The dried product is then milled to various sizes from powder to granules. The dehydration plant operates 24 hours/day 7 days a week. Currently 80 people are employed full-time at the plant. The dehydrated onion and garlic are used in condiments, soups, sauces and salad dressing.« less

  9. X-wing fly-by-wire vehicle management system

    NASA Technical Reports Server (NTRS)

    Fischer, Jr., William C. (Inventor)

    1990-01-01

    A complete, computer based, vehicle management system (VMS) for X-Wing aircraft using digital fly-by-wire technology controlling many subsystems and providing functions beyond the classical aircraft flight control system. The vehicle management system receives input signals from a multiplicity of sensors and provides commands to a large number of actuators controlling many subsystems. The VMS includes--segregating flight critical and mission critical factors and providing a greater level of back-up or redundancy for the former; centralizing the computation of functions utilized by several subsystems (e.g. air data, rotor speed, etc.); integrating the control of the flight control functions, the compressor control, the rotor conversion control, vibration alleviation by higher harmonic control, engine power anticipation and self-test, all in the same flight control computer (FCC) hardware units. The VMS uses equivalent redundancy techniques to attain quadruple equivalency levels; includes alternate modes of operation and recovery means to back-up any functions which fail; and uses back-up control software for software redundancy.

  10. Expedition 10 Preflight

    NASA Image and Video Library

    2004-10-08

    From left to right, Russian Space Forces cosmonaut Yuri Shargin, Expedition 10 Commander and NASA Science Officer Leroy Chiao, Flight Engineer and Soyuz Commander Salizhan Sharipov, Expedition 10 backup Soyuz Commander Valery Tokarev and backup Expedition Commander Bill McArthur speak with officials from behind glass after having conducted a final inspection of their Soyuz TMA-5 spacecraft on Saturday, October 9, 2004, at the Baikonur Cosmodrome in Kazakhstan in preparation for their launch October 14 to the International Space Station. The Soyuz vehicle will be mated to its booster rocket October 11 in preparation for its rollout to the Central Asian launch pad October 12. Photo Credit: (NASA/Bill Ingalls)

  11. Data processing for water monitoring system

    NASA Technical Reports Server (NTRS)

    Monford, L.; Linton, A. T.

    1978-01-01

    Water monitoring data acquisition system is structured about central computer that controls sampling and sensor operation, and analyzes and displays data in real time. Unit is essentially separated into two systems: computer system, and hard wire backup system which may function separately or with computer.

  12. BCR/ABL downregulates DNA-PK(CS)-dependent and upregulates backup non-homologous end joining in leukemic cells.

    PubMed

    Poplawski, Tomasz; Blasiak, Janusz

    2010-06-01

    Non-homologous end joining (NHEJ) and homologous recombination repair (HRR) are the main mechanisms involved in the processing of DNA double strand breaks (DSBs) in humans. We showed previously that the oncogenic tyrosine kinase BCR/ABL stimulated DSBs repair by HRR. To evaluate the role of BCR/ABL in DSBs repair by NHEJ we examined the ability of leukemic BCR/ABL-expressing cell line BV173 to repair DNA damage induced by two DNA topoisomerase II inhibitors: etoposide and sobuzoxane. DNA lesions induced by sobuzoxane are repaired by a NHEJ pathway which is dependent on the catalytic subunit of protein kinase dependent on DNA (DNA-PK(CS); D-NHEJ), whereas damage evoked by etoposide are repaired by two distinct NHEJ pathways, dependent on or independent of DNA-PK(CS) (backup NHEJ, B-NHEJ). Cells incubated with STI571, a highly specific inhibitor of BCR/ABL, displayed resistance to these agents associated with an accelerated kinetics of DSBs repair, as measured by the neutral comet assay and pulsed field gel electrophoresis. However, in a functional NHEJ assay, cells preincubated with STI571 repaired DSBs induced by a restriction enzyme with a lower efficacy than without the preincubation and addition of wortmannin, a specific inhibitor of DNA-PK(CS), did not change efficacy of the NHEJ reaction. We suggest that BCR/ABL switch on B-NHEJ which is more error-prone then D-NHEJ and in such manner contribute to the increase of the genomic instability of leukemic cells.

  13. The Size and Scope of Collegiate Athletic Training Facilities and Staffing.

    PubMed

    Gallucci, Andrew R; Petersen, Jeffrey C

    2017-08-01

      Athletic training facilities have been described in terms of general design concepts and from operational perspectives. However, the size and scope of athletic training facilities, along with staffing at different levels of intercollegiate competition, have not been quantified.   To define the size and scope of athletic training facilities and staffing levels at various levels of intercollegiate competition. To determine if differences existed in facilities (eg, number of facilities, size of facilities) and staffing (eg, full time, part time) based on the level of intercollegiate competition.   Cross-sectional study.   Web-based survey.   Athletic trainers (ATs) who were knowledgeable about the size and scope of athletic training programs.   Athletic training facility size in square footage; the AT's overall facility satisfaction; athletic training facility component spaces, including satellite facilities, game-day facilities, offices, and storage areas; and staffing levels, including full-time ATs, part-time ATs, and undergraduate students.   The survey was completed by 478 ATs (response rate = 38.7%) from all levels of competition. Sample means for facilities were 3124.7 ± 4425 ft 2 (290.3 ± 411 m 2 ) for the central athletic training facility, 1013 ± 1521 ft 2 (94 ± 141 m 2 ) for satellite athletic training facilities, 1272 ± 1334 ft 2 (118 ± 124 m 2 ) for game-day athletic training facilities, 388 ± 575 ft 2 (36 ± 53 m 2 ) for athletic training offices, and 424 ± 884 ft 2 (39 ± 82 m 2 ) for storage space. Sample staffing means were 3.8 ± 2.5 full-time ATs, 1.6 ± 2.5 part-time ATs, 25 ± 17.6 athletic training students, and 6.8 ± 7.2 work-study students. Division I schools had greater resources in multiple categories (P < .001). Differences among other levels of competition were not as well defined. Expansion or renovation of facilities in recent years was common, and almost half of ATs reported that upgrades have been approved for

  14. Central Control Room in the Engine Research Building

    NASA Image and Video Library

    1968-11-21

    Operators in the Engine Research Building’s Central Control Room at the National Aeronautics and Space Administration (NASA) Lewis Research Center. The massive 4.25-acre Engine Research Building contains dozens of test cells, test stands, and altitude chambers. A powerful a collection of compressors and exhausters located in the central portion of the basement provides process air and exhaust for these test areas. This system is connected to similar process air systems in the laboratory’s other large test facilities. The Central Control Room coordinates this activity and communicates with the local utilities. The panels on the wall contain schematics with indicator lights and instrumentation for the atmospheric exhaust, altitude exhaust, refrigerated air, and process air systems. The process air equipment included twelve exhausters, four compressors, refrigeration system, cooling water, and an exhaust system. The operators in the control room kept in contact with engineers running the process air system and those conducting the tests in the test cells. The operators also coordinated with the local power companies to make sure enough electricity was available to operate the powerful compressors and exhausters.

  15. Improving water, sanitation and hygiene in health-care facilities, Liberia.

    PubMed

    Abrampah, Nana Mensah; Montgomery, Maggie; Baller, April; Ndivo, Francis; Gasasira, Alex; Cooper, Catherine; Frescas, Ruben; Gordon, Bruce; Syed, Shamsuzzoha Babar

    2017-07-01

    The lack of proper water and sanitation infrastructures and poor hygiene practices in health-care facilities reduces facilities' preparedness and response to disease outbreaks and decreases the communities' trust in the health services provided. To improve water and sanitation infrastructures and hygiene practices, the Liberian health ministry held multistakeholder meetings to develop a national water, sanitation and hygiene and environmental health package. A national train-the-trainer course was held for county environmental health technicians, which included infection prevention and control focal persons; the focal persons acted as change agents. In Liberia, only 45% of 701 surveyed health-care facilities had an improved water source in 2015, and only 27% of these health-care facilities had proper disposal for infectious waste. Local ownership, through engagement of local health workers, was introduced to ensure development and refinement of the package. In-county collaborations between health-care facilities, along with multisectoral collaboration, informed national level direction, which led to increased focus on water and sanitation infrastructures and uptake of hygiene practices to improve the overall quality of service delivery. National level leadership was important to identify a vision and create an enabling environment for changing the perception of water, sanitation and hygiene in health-care provision. The involvement of health workers was central to address basic infrastructure and hygiene practices in health-care facilities and they also worked as stimulators for sustainable change. Further, developing a long-term implementation plan for national level initiatives is important to ensure sustainability.

  16. How Do I Start a Property Records System?

    ERIC Educational Resources Information Center

    Whyman, Wynne

    2003-01-01

    A property records system organizes data to be utilized by a camp's facilities department and integrated into other areas. Start by deciding what records to keep and allotting the time. Then develop consistent procedures, including organizing data, creating a catalog, making back-up copies, and integrating procedures. Use software tools. A good…

  17. 77 FR 56914 - Privacy Act of 1974

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-14

    ... components in legal proceedings before a court or adjudicative body, provided that, in each case, the agency... care facility where the child care program is in place (in most cases, backup information is stored at... components in legal proceedings before a court or adjudicative body, provided that, in each case, the agency...

  18. Control of an H1N1 outbreak in a correctional facility in central Taiwan.

    PubMed

    Chao, Wen-Cheng; Liu, Po-Yu; Wu, Chieh-Liang

    2017-04-01

    Controlling the outbreak of H1N1 in correctional facilities is difficult due to the inevitable close and prolonged contact between inmates. The current study reports an H1N1 outbreak in a correction facility and investigates the effectiveness of oseltamivir to control the spread of H1N1. All 2690 inmates at the prison received medical service from a single hospital. A list of patients with a diagnosis of influenza was compiled based on medical diagnoses with respiratory symptoms during the outbreak period. The outbreak was then investigated using both chart review and questionnaires. In the 4-week outbreak period, 24.6% (663/2690) of inmates experienced influenza-associated symptoms, 50.5% (335/663) fulfilled the criteria for influenza-like illness (ILI) with fever, and the overall attack rate of ILI was 12.8%. Twelve inmates were admitted for complicated influenza, and three of them experienced respiratory failure. Oseltamivir was provided at the end of the 2nd week, and the effectiveness of oseltamivir in the 1004 inmates from seven major sections in the prison was analyzed. The ILI incidence rate reduced from 12.6 ± 4.1% between the 1st and 2nd weeks to 4.8 ± 2.4% between the 3rd and 4th weeks (p = 0.018) after the oseltamivir intervention. In the 878 uninfected inmates 47.0% (413/878) of inmates received prophylactic oseltamivir at the end of the 2nd week, the incidence of ILI was lower than those without prophylaxis (6.2% versus 2.4%; p = 0.013). H1N1 influenza spread rapidly in the correctional facility. The use of oseltamivir may be a practical intervention to control an H1N1 outbreak an enclosed environment such as this. Copyright © 2015. Published by Elsevier B.V.

  19. [Centralization in obstetrics: pros and cons].

    PubMed

    Roemer, V M; Ramb, S

    1996-01-01

    Possible advantages and disadvantages of a general centralization of German obstetric facilities are analysed in the study. The need for centralization of risk cases, especially premature births (regionalization) is pointed out. Centralization appears appropriate, since every fifth maternity unit in Germany (19.78%) has 300 or fewer deliveries per year. This one fifth of perinatal clinics accounts for 6.3% of all deliveries (N = 49450). There are appreciable differences between the old and new federal states (Bundesländer): in the recently acceded federal states, 48.7% of all perinatal clinics have deliveries of 300 and less per year. This group of perinatal clinics accounts for 29% of all deliveries in the new federal states. We have carried out a survey of the mother's attitude to centralization: out of 416 patients in the Detmold women's hospital whose mean age was 29.0 +/- 4.2 years, 90.4% were not in favor of general centralization of obstetrics. 43% were also against a centralization of risk cases (regionalization). 75% of the women surveyed objected to centralized obstetrics because of the 'possible absence of the family', the 'possible absence of students and trainees' (44.9%), the 'unfamiliarity with staff and premises' (41.8%) and 'fear of anonymity' (44.5%). The majority of all women (84.1%) did not want to have a drive more than 20 km to an obstetrics center. Fear of 'delivery in a taxi'(78.6%), the 'fear that the husband will come too late to the delivery' (65.4%) and that the 'overall course of the delivery might not be adequate for reasons of time'. The presence of a pediatrics department in conjunction with the perinatal clinic was rated very positively (93%). It is concluded from the data and further juridical considerations that centralization of risk cases (regionalization) is indispensable in the near future and that somewhat more further into the future decentralization should be carried out by closing obstetrics departments with substantially

  20. Unique life sciences research facilities at NASA Ames Research Center

    NASA Technical Reports Server (NTRS)

    Mulenburg, G. M.; Vasques, M.; Caldwell, W. F.; Tucker, J.

    1994-01-01

    The Life Science Division at NASA's Ames Research Center has a suite of specialized facilities that enable scientists to study the effects of gravity on living systems. This paper describes some of these facilities and their use in research. Seven centrifuges, each with its own unique abilities, allow testing of a variety of parameters on test subjects ranging from single cells through hardware to humans. The Vestibular Research Facility allows the study of both centrifugation and linear acceleration on animals and humans. The Biocomputation Center uses computers for 3D reconstruction of physiological systems, and interactive research tools for virtual reality modeling. Psycophysiological, cardiovascular, exercise physiology, and biomechanical studies are conducted in the 12 bed Human Research Facility and samples are analyzed in the certified Central Clinical Laboratory and other laboratories at Ames. Human bedrest, water immersion and lower body negative pressure equipment are also available to study physiological changes associated with weightlessness. These and other weightlessness models are used in specialized laboratories for the study of basic physiological mechanisms, metabolism and cell biology. Visual-motor performance, perception, and adaptation are studied using ground-based models as well as short term weightlessness experiments (parabolic flights). The unique combination of Life Science research facilities, laboratories, and equipment at Ames Research Center are described in detail in relation to their research contributions.

  1. Tracking implementation and (un)intended consequences: a process evaluation of an innovative peripheral health facility financing mechanism in Kenya

    PubMed Central

    Waweru, Evelyn; Goodman, Catherine; Kedenge, Sarah; Tsofa, Benjamin; Molyneux, Sassy

    2016-01-01

    In many African countries, user fees have failed to achieve intended access and quality of care improvements. Subsequent user fee reduction or elimination policies have often been poorly planned, without alternative sources of income for facilities. We describe early implementation of an innovative national health financing intervention in Kenya; the health sector services fund (HSSF). In HSSF, central funds are credited directly into a facility’s bank account quarterly, and facility funds are managed by health facility management committees (HFMCs) including community representatives. HSSF is therefore a finance mechanism with potential to increase access to funds for peripheral facilities, support user fee reduction and improve equity in access. We conducted a process evaluation of HSSF implementation based on a theory of change underpinning the intervention. Methods included interviews at national, district and facility levels, facility record reviews, a structured exit survey and a document review. We found impressive achievements: HSSF funds were reaching facilities; funds were being overseen and used in a way that strengthened transparency and community involvement; and health workers’ motivation and patient satisfaction improved. Challenges or unintended outcomes included: complex and centralized accounting requirements undermining efficiency; interactions between HSSF and user fees leading to difficulties in accessing crucial user fee funds; and some relationship problems between key players. Although user fees charged had not increased, national reduction policies were still not being adhered to. Finance mechanisms can have a strong positive impact on peripheral facilities, and HFMCs can play a valuable role in managing facilities. Although fiduciary oversight is essential, mechanisms should allow for local decision-making and ensure that unmanageable paperwork is avoided. There are also limits to what can be achieved with relatively small funds in

  2. CENTRALIZED TREATMENT OF METAL FINISHING WASTES AT A CLEVELAND RESOURCE RECOVERY PARK: PART 1. DESIGN AND COSTS. PART 2. FINANCING. PART 3. SITE INVESTIGATION

    EPA Science Inventory

    The report, in three parts, describes the characteristics of the Cleveland (OH) area electroplating industry and an approach and design for a centralized facility to treat cyanide and heavy metal wastes generated by this industry. The facility is termed the Resource Recovery Park...

  3. Opportunities for Automated Demand Response in California Wastewater Treatment Facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aghajanzadeh, Arian; Wray, Craig; McKane, Aimee

    Previous research over a period of six years has identified wastewater treatment facilities as good candidates for demand response (DR), automated demand response (Auto-­DR), and Energy Efficiency (EE) measures. This report summarizes that work, including the characteristics of wastewater treatment facilities, the nature of the wastewater stream, energy used and demand, as well as details of the wastewater treatment process. It also discusses control systems and automated demand response opportunities. Furthermore, this report summarizes the DR potential of three wastewater treatment facilities. In particular, Lawrence Berkeley National Laboratory (LBNL) has collected data at these facilities from control systems, submetered processmore » equipment, utility electricity demand records, and governmental weather stations. The collected data were then used to generate a summary of wastewater power demand, factors affecting that demand, and demand response capabilities. These case studies show that facilities that have implemented energy efficiency measures and that have centralized control systems are well suited to shed or shift electrical loads in response to financial incentives, utility bill savings, and/or opportunities to enhance reliability of service. In summary, municipal wastewater treatment energy demand in California is large, and energy-­intensive equipment offers significant potential for automated demand response. In particular, large load reductions were achieved by targeting effluent pumps and centrifuges. One of the limiting factors to implementing demand response is the reaction of effluent turbidity to reduced aeration at an earlier stage of the process. Another limiting factor is that cogeneration capabilities of municipal facilities, including existing power purchase agreements and utility receptiveness to purchasing electricity from cogeneration facilities, limit a facility’s potential to participate in other DR activities.« less

  4. Interactive dependency curves for resilience management.

    PubMed

    Petit, Frédéric; Wallace, Kelly; Phillip, Julia

    Physical dependencies are a fundamental consideration when assessing the resilience of an organisation and, ultimately, the resilience of a region. Every organisation needs specific resources for supporting its operations. A disruption in the supply of these resources can severely impact business continuity. It is important to characterise dependencies thoroughly when seeking to reduce the extent an organisation is directly affected by the missions, functions and operations of other organisations. The general protocol when addressing each critical resource is to determine the use for the resource, whether there are redundant services providing the resource, and what protections, backup equipment and arrangements are in place to maintain service. Finally, the criticality of the resource is determined by estimating the time it will take for the facility to experience a severe impact once primary service is lost and what percentage of facility operations can be maintained without backup service in place, as well as identifying whether any external regulations/policies are in place that require shutdown of the facility because of service disruption owing to lack of a critical resource. All of this information can be presented in the form of interactive dependency curves that help anticipate and manage the effect(s) of a disruption on critical resources supply.

  5. Thermal-hydraulic analysis of the coil test facility for CFETR.

    PubMed

    Ren, Yong; Liu, Xiaogang; Li, Junjun; Wang, Zhaoliang; Qiu, Lilong; Du, Shijun; Li, Guoqiang; Gao, Xiang

    2016-01-01

    Performance test of the China Fusion Engineering Test Reactor (CFETR) central solenoid (CS) and toroidal field (TF) insert coils is of great importance to evaluate the CFETR magnet performance in relevant operation conditions. The superconducting magnet of the coil test facility for CFETR is being designed with the aim of providing a background magnetic field to test the CFETR CS insert and TF insert coils. The superconducting magnet consists of the inner module with Nb 3 Sn coil and the outer module with NbTi coil. The superconducting magnet is designed to have a maximum magnetic field of 12.59 T and a stored energy of 436.6 MJ. An active quench protection circuit and the positive temperature coefficient dump resistor were adopted to transfer the stored magnetic energy. The temperature margin behavior of the test facility for CFETR satisfies the design criteria. The quench analysis of the test facility shows that the cable temperature and the helium pressure inside the jacket are within the design criteria.

  6. LAFD: TA-55 RLUOB/CUB Facility Familiarization Tour, OJT #55265

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rutherford, Victor Stephen

    2017-09-14

    Los Alamos National Laboratory (LANL) conducts familiarization tours for personnel of the Los Alamos County Fire Department (LAFD) at the RLUOB/CUB, technical area (TA)-55, 400/440, facility, Radiological Laboratory Utility Office Building (RLUOB)/Central Utility Building (CUB). These familiarization tours are official LANL business; the purpose of these tours is to orient LAFD firefighters to the facility so that they can respond efficiently and quickly to a variety of emergency situations. This orientation includes, among other topics, the ingress and egress of the area and buildings, layout and organization of the facility, evacuation procedures and assembly points, and areas of concern withinmore » the various buildings at the facility. LAFD firefighters have the skills and abilities to perform firefighting operations and other emergency response tasks that cannot be provided by other LANL personnel who have the required clearance level. This handout provides details of the information, along with maps and diagrams, to be presented during the familiarization tours. The handout is distributed to the trainees at the time of the tour; a corresponding checklist is also used as guidance during the familiarization tours to ensure that all required information is presented to LAFD personnel.« less

  7. Poly(ADP-ribose)polymerases are involved in microhomology mediated back-up non-homologous end joining in Arabidopsis thaliana.

    PubMed

    Jia, Qi; den Dulk-Ras, Amke; Shen, Hexi; Hooykaas, Paul J J; de Pater, Sylvia

    2013-07-01

    Besides the KU-dependent classical non-homologous end-joining (C-NHEJ) pathway, an alternative NHEJ pathway first identified in mammalian systems, which is often called the back-up NHEJ (B-NHEJ) pathway, was also found in plants. In mammalian systems PARP was found to be one of the essential components in B-NHEJ. Here we investigated whether PARP1 and PARP2 were also involved in B-NHEJ in Arabidopsis. To this end Arabidopsis parp1, parp2 and parp1parp2 (p1p2) mutants were isolated and functionally characterized. The p1p2 double mutant was crossed with the C-NHEJ ku80 mutant resulting in the parp1parp2ku80 (p1p2k80) triple mutant. As expected, because of their role in single strand break repair (SSBR) and base excision repair (BER), the p1p2 and p1p2k80 mutants were shown to be sensitive to treatment with the DNA damaging agent MMS. End-joining assays in cell-free leaf protein extracts of the different mutants using linear DNA substrates with different ends reflecting a variety of double strand breaks were performed. The results showed that compatible 5'-overhangs were accurately joined in all mutants, that KU80 protected the ends preventing the formation of large deletions and that PARP proteins were involved in microhomology mediated end joining (MMEJ), one of the characteristics of B-NHEJ.

  8. Assessing the potential of rural and urban private facilities in implementing child health interventions in Mukono district, central Uganda-a cross sectional study.

    PubMed

    Rutebemberwa, Elizeus; Buregyeya, Esther; Lal, Sham; Clarke, Sîan E; Hansen, Kristian S; Magnussen, Pascal; LaRussa, Philip; Mbonye, Anthony K

    2016-07-15

    Private facilities are the first place of care seeking for many sick children. Involving these facilities in child health interventions may provide opportunities to improve child welfare. The objective of this study was to assess the potential of rural and urban private facilities in diagnostic capabilities, operations and human resource in the management of malaria, pneumonia and diarrhoea. A survey was conducted in pharmacies, private clinics and drug shops in Mukono district in October 2014. An assessment was done on availability of diagnostic equipment for malaria, record keeping, essential drugs for the treatment of malaria, pneumonia and diarrhoea; the sex, level of education, professional and in-service training of the persons found attending to patients in these facilities. A comparison was made between urban and rural facilities. Univariate and bivariate analysis was done. A total of 241 private facilities were assessed with only 47 (19.5 %) being in rural areas. Compared to urban areas, rural private facilities were more likely to be drug shops (OR 2.80; 95 % CI 1.23-7.11), less likely to be registered (OR 0.31; 95 % CI 0.16-0.60), not have trained clinicians, less likely to have people with tertiary education (OR 0.34; 95 % CI 0.17-0.66) and less likely to have zinc tablets (OR 0.38; 95 % CI 0.19-0.78). In both urban and rural areas, there was low usage of stock cards and patient registers. About half of the facilities in both rural and urban areas attended to at least one sick child in the week prior to the interview. There were big gaps between rural and urban private facilities with rural ones having less trained personnel and less zinc tablets' availability. In both rural and urban areas, record keeping was low. Child health interventions need to build capacity of private facilities with special focus on rural areas where child mortality is higher and capacity of facilities lower.

  9. The Nova Upgrade Facility for ICF ignition and gain

    NASA Astrophysics Data System (ADS)

    Lowdermilk, W. H.; Campbell, E. M.; Hunt, J. T.; Murray, J. R.; Storm, E.; Tobin, M. T.; Trenholme, J. B.

    1992-01-01

    Research on Inertial Confinement Fusion (ICF) is motivated by its potential defense and civilian applications, including ultimately the generation of electric power. The U.S. ICF Program was reviewed recently by the National Academy of Science (NAS) and the Fusion Policy Advisory Committee (FPAC). Both committees issued final reports in 1991 which recommended that first priority in the ICF program be placed on demonstrating fusion ignition and modest gain (G less than 10). The U.S. Department of Energy and Lawrence Livermore National Laboratory (LLNL) have proposed an upgrade of the existing Nova Laser Facility at LLNL to accomplish these goals. Both the NAS and FPAC have endorsed the upgrade of Nova as the optimal path to achieving ignition and gain. Results from Nova Upgrade Experiments will be used to define requirements for driver and target technology both for future high-yield military applications, such as the Laboratory Microfusion Facility (LMF) proposed by the Department of Energy, and for high-gain energy applications leading to an ICF engineering test facility. The central role and modifications which Nova Upgrade would play in the national ICF strategy are described.

  10. National facilities study. Volume 4: Space operations facilities task group

    NASA Technical Reports Server (NTRS)

    1994-01-01

    The principal objectives of the National Facilities Study (NFS) were to: (1) determine where U.S. facilities do not meet national aerospace needs; (2) define new facilities required to make U.S. capabilities 'world class' where such improvements are in the national interest; (3) define where consolidation and phase-out of existing facilities is appropriate; and (4) develop a long-term national plan for world-class facility acquisition and shared usage. The Space Operations Facilities Task Group defined discrete tasks to accomplish the above objectives within the scope of the study. An assessment of national space operations facilities was conducted to determine the nation's capability to meet the requirements of space operations during the next 30 years. The mission model used in the study to define facility requirements is described in Volume 3. Based on this model, the major focus of the Task Group was to identify any substantive overlap or underutilization of space operations facilities and to identify any facility shortfalls that would necessitate facility upgrades or new facilities. The focus of this initial study was directed toward facility recommendations related to consolidations, closures, enhancements, and upgrades considered necessary to efficiently and effectively support the baseline requirements model. Activities related to identifying facility needs or recommendations for enhancing U.S. international competitiveness and achieving world-class capability, where appropriate, were deferred to a subsequent study phase.

  11. Plans for an ERL Test Facility at CERN

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jensen, Erik; Bruning, O S; Calaga, Buchi Rama Rao

    2014-12-01

    The baseline electron accelerator for LHeC and one option for FCC-he is an Energy Recovery Linac. To prepare and study the necessary key technologies, CERNhas started – in collaboration with JLAB and Mainz University – the conceptual design of an ERL Test Facility (ERL-TF). Staged construction will allow the study under different conditions with up to 3 passes, beam energies of up to about 1 GeV and currents of up to 50 mA. The design and development of superconducting cavity modules, including coupler and HOM damper designs, are also of central importance for other existing and future accelerators and theirmore » tests are at the heart of the current ERL-TF goals. However, the ERL-TF could also provide a unique infrastructure for several applications that go beyond developing and testing the ERL technology at CERN. In addition to experimental studies of beam dynamics, operational and reliability issues in an ERL, it could equally serve for quench tests of superconducting magnets, as physics experimental facility on its own right or as test stand for detector developments. This contribution will describe the goals and the concept of the facility and the status of the R&D.« less

  12. Bird Mortality in Oil Field Wastewater Disposal Facilities

    NASA Astrophysics Data System (ADS)

    Ramirez, Pedro

    2010-11-01

    Commercial and centralized oilfield wastewater disposal facilities (COWDFs) are used in the Western United States for the disposal of formation water produced from oil and natural gas wells. In Colorado, New Mexico, Utah, and Wyoming, COWDFs use large evaporation ponds to dispose of the wastewater. Birds are attracted to these large evaporation ponds which, if not managed properly, can cause wildlife mortality. The U.S. Fish and Wildlife Service (USFWS) and the U.S. Environmental Protection Agency (EPA) conducted 154 field inspections of 28 COWDFs in Wyoming from March 1998 through September 2008 and documented mortality of birds and other wildlife in 9 COWDFs. Of 269 bird carcasses recovered from COWDFs, grebes (Family Podicipedidae) and waterfowl (Anatidae) were the most frequent casualties. Most mortalities were attributed to oil on evaporation ponds, but sodium toxicity and surfactants were the suspected causes of mortality at three COWDFs. Although the oil industry and state and federal regulators have made much progress in reducing bird mortality in oil and gas production facilities, significant mortality incidents continue in COWDFs, particularly older facilities permitted in the early 1980’s. Inadequate operation and management of these COWDFs generally results in the discharge of oil into the large evaporation ponds which poses a risk for birds and other wildlife.

  13. Bird mortality in oil field wastewater disposal facilities.

    PubMed

    Ramirez, Pedro

    2010-11-01

    Commercial and centralized oilfield wastewater disposal facilities (COWDFs) are used in the Western United States for the disposal of formation water produced from oil and natural gas wells. In Colorado, New Mexico, Utah, and Wyoming, COWDFs use large evaporation ponds to dispose of the wastewater. Birds are attracted to these large evaporation ponds which, if not managed properly, can cause wildlife mortality. The U.S. Fish and Wildlife Service (USFWS) and the U.S. Environmental Protection Agency (EPA) conducted 154 field inspections of 28 COWDFs in Wyoming from March 1998 through September 2008 and documented mortality of birds and other wildlife in 9 COWDFs. Of 269 bird carcasses recovered from COWDFs, grebes (Family Podicipedidae) and waterfowl (Anatidae) were the most frequent casualties. Most mortalities were attributed to oil on evaporation ponds, but sodium toxicity and surfactants were the suspected causes of mortality at three COWDFs. Although the oil industry and state and federal regulators have made much progress in reducing bird mortality in oil and gas production facilities, significant mortality incidents continue in COWDFs, particularly older facilities permitted in the early 1980's. Inadequate operation and management of these COWDFs generally results in the discharge of oil into the large evaporation ponds which poses a risk for birds and other wildlife.

  14. Engine Research Building’s Central Control Room

    NASA Image and Video Library

    1948-07-21

    Operators in the Engine Research Building’s Central Control Room at the National Advisory Committee for Aeronautics (NACA) Lewis Flight Propulsion Laboratory. The massive 4.25-acre Engine Research Building contains dozens of test cells, test stands, and altitude chambers. A powerful collection of compressors and exhausters located in the central portion of the basement provided process air and exhaust for these test areas. This system is connected to similar process air systems in the laboratory’s other large test facilities. The Central Control Room coordinates this activity and communicates with the local utilities. This photograph was taken just after a major upgrade to the control room in 1948. The panels on the wall contain rudimentary floor plans of the different Engine Research Building sections with indicator lights and instrumentation for each test cell. The process air equipment included 12 exhausters, four compressors, a refrigeration system, cooling water, and an exhaust system. The operators in the control room kept in contact with engineers running the process air system and those conducting the tests in the test cells. The operators also coordinated with the local power companies to make sure enough electricity was available to operate the powerful compressors and exhausters.

  15. Dance Facilities.

    ERIC Educational Resources Information Center

    Ashton, Dudley, Ed.; Irey, Charlotte, Ed.

    This booklet represents an effort to assist teachers and administrators in the professional planning of dance facilities and equipment. Three chapters present the history of dance facilities, provide recommended dance facilities and equipment, and offer some adaptations of dance facilities and equipment, for elementary, secondary and college level…

  16. Together but apart: Caring for a spouse with dementia resident in a care facility.

    PubMed

    Hemingway, Dawn; MacCourt, Penny; Pierce, Joanna; Strudsholm, Tina

    2016-07-01

    This longitudinal, exploratory study was designed to better understand the lived experience of spousal caregivers age 60 and older providing care to partners with Alzheimer's disease and related dementias resident in a care facility. Twenty eight spousal caregivers were interviewed up to three times over a period of 2 years, and long-term care facility staff from four locations across British Columbia (BC), Canada participated in four focus groups. Thematic analysis of interview and focus group transcripts revealed a central, unifying theme 'together but apart'. The results identify key targets for policy makers and service providers to support positive health and well-being outcomes for spousal caregivers providing care to their partners diagnosed with Alzheimer's disease and related dementia and living in care facilities. © The Author(s) 2014.

  17. Central Asia: Regional Developments and Implications for U.S. Interests

    DTIC Science & Technology

    2009-11-20

    Central Asia. Other officials have stated that a large - scale influx has not yet occurred. Actions of the IMU and IJU in Germany and Elsewhere Officials...Independence: Regional Tensions and Conflicts”) that stated that “as large - scale military operations against terrorism have come to an end in... breeder reactor at Aktau that was the world’s only nuclear desalinization facility. In 1997 and 1999, U.S.-Kazakh accords were signed on

  18. Tracking implementation and (un)intended consequences: a process evaluation of an innovative peripheral health facility financing mechanism in Kenya.

    PubMed

    Waweru, Evelyn; Goodman, Catherine; Kedenge, Sarah; Tsofa, Benjamin; Molyneux, Sassy

    2016-03-01

    In many African countries, user fees have failed to achieve intended access and quality of care improvements. Subsequent user fee reduction or elimination policies have often been poorly planned, without alternative sources of income for facilities. We describe early implementation of an innovative national health financing intervention in Kenya; the health sector services fund (HSSF). In HSSF, central funds are credited directly into a facility's bank account quarterly, and facility funds are managed by health facility management committees (HFMCs) including community representatives. HSSF is therefore a finance mechanism with potential to increase access to funds for peripheral facilities, support user fee reduction and improve equity in access. We conducted a process evaluation of HSSF implementation based on a theory of change underpinning the intervention. Methods included interviews at national, district and facility levels, facility record reviews, a structured exit survey and a document review. We found impressive achievements: HSSF funds were reaching facilities; funds were being overseen and used in a way that strengthened transparency and community involvement; and health workers' motivation and patient satisfaction improved. Challenges or unintended outcomes included: complex and centralized accounting requirements undermining efficiency; interactions between HSSF and user fees leading to difficulties in accessing crucial user fee funds; and some relationship problems between key players. Although user fees charged had not increased, national reduction policies were still not being adhered to. Finance mechanisms can have a strong positive impact on peripheral facilities, and HFMCs can play a valuable role in managing facilities. Although fiduciary oversight is essential, mechanisms should allow for local decision-making and ensure that unmanageable paperwork is avoided. There are also limits to what can be achieved with relatively small funds in

  19. Calculated organ doses for Mayak production association central hall using ICRP and MCNP.

    PubMed

    Choe, Dong-Ok; Shelkey, Brenda N; Wilde, Justin L; Walk, Heidi A; Slaughter, David M

    2003-03-01

    As part of an ongoing dose reconstruction project, equivalent organ dose rates from photons and neutrons were estimated using the energy spectra measured in the central hall above the graphite reactor core located in the Russian Mayak Production Association facility. Reconstruction of the work environment was necessary due to the lack of personal dosimeter data for neutrons in the time period prior to 1987. A typical worker scenario for the central hall was developed for the Monte Carlo Neutron Photon-4B (MCNP) code. The resultant equivalent dose rates for neutrons and photons were compared with the equivalent dose rates derived from calculations using the conversion coefficients in the International Commission on Radiological Protection Publications 51 and 74 in order to validate the model scenario for this Russian facility. The MCNP results were in good agreement with the results of the ICRP publications indicating the modeling scenario was consistent with actual work conditions given the spectra provided. The MCNP code will allow for additional orientations to accurately reflect source locations.

  20. Widespread Dependence of Backup NHEJ on Growth State: Ramifications for the Use of DNA-PK Inhibitors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Singh, Satyendra K.; Wu Wenqi; Zhang Lihua

    2011-02-01

    Purpose: The backup pathway of nonhomologous end joining (B-NHEJ) enables cells to process DNA double-strand breaks (DSBs) when the DNA-PK-dependent pathway of NHEJ (D-NHEJ) is compromised. Our previous results show marked reduction in the activity of B-NHEJ when LIG4{sup -/-} mouse embryo fibroblasts (MEFs) cease to grow and enter a plateau phase. The dependence of B-NHEJ on growth state is substantially stronger than that of D-NHEJ and points to regulatory mechanisms or processing determinants that require elucidation. Because the different D-NHEJ mutants show phenotypes distinct in their details, it is necessary to characterize the dependence of their DSB repair capacitymore » on growth state and to explore species-specific responses. Methods and Materials: DSB repair was measured in cells of different genetic background from various species using pulsed-field gel electrophoresis, or the formation of {gamma}-H2AX foci, at different stages of growth. Results: Using pulsed-field gel electrophoresis, we report a marked reduction of B-NHEJ during the plateau phase of growth in KU and XRCC4, mouse or Chinese hamster, mutants. Notably, this reduction is only marginal in DNA-PKcs-deficient cells. However, reduced B-NHEJ is also observed in repair proficient, plateau-phase cells after treatment with DNA-PK inhibitors. The reduction of B-NHEJ activity in the plateau phase of growth does not derive from the reduced expression of participating proteins, is detectable by {gamma}-H2AX foci analysis, and leads to enhanced cell killing. Conclusions: These results further document the marked dependence on growth state of an essential DSB repair pathway and show the general nature of the effect. Molecular characterization of the mechanism underlying this response will help to optimize the administration of DNA repair inhibitors as adjuvants in radiation therapy.« less

  1. Repositioning the Facilities in Technical College Workshops for Efficiency: A Case Study of North Central Nigeria

    ERIC Educational Resources Information Center

    Umar, Ibrahim Y.; Ma'aji, Abdullahi S.

    2010-01-01

    This article focuses on assessing the facilities in Government Technical College workshops in the context of a developing country. A descriptive survey design was adopted. Two research questions and a hypothesis were formulated to guide the study. A 35-item questionnaire was developed based on the National Board for Technical Education (NBTE)…

  2. Gulf Coast Deep Water Port Facilities study. Appendix B. North Central Gulf Hydrobiological Zones.

    DTIC Science & Technology

    1973-04-01

    bottom and surface salinities , but their effect is more noticeable at the surface. Because of variation in these factors along the Gulf Coast... effects of discharge on salinity have been considered above. Numerous streams empty into the Gulf of Mexico along its north central portion but the...1967) investigated various aspects of osmoregulation in blue crabs in Mississippi Sound and adjacent waters and observed that salinity and temperature

  3. CSP cogeneration of electricity and desalinated water at the Pentakomo field facility

    NASA Astrophysics Data System (ADS)

    Papanicolas, C. N.; Bonanos, A. M.; Georgiou, M. C.; Guillen, E.; Jarraud, N.; Marakkos, C.; Montenon, A.; Stiliaris, E.; Tsioli, E.; Tzamtzis, G.; Votyakov, E. V.

    2016-05-01

    The Cyprus Institute's Pentakomo Field Facility (PFF) is a major infrastructure for research, development and testing of technologies relating to concentrated solar power (CSP) and solar seawater desalination. It is located at the south coast of Cyprus near the sea and its environmental conditions are fully monitored. It provides a test facility specializing in the development of CSP systems suitable for island and coastal environments with particular emphasis on small units (<25 MWth) endowed with substantial storage, suitable for use in isolation or distributed in small power grids. The first major experiment to take place at the PFF concerns the development of a pilot/experimental facility for the co-generation of electricity and desalinated seawater from CSP. Specifically, the experimental plant consists of a heliostat-central receiver system for solar harvesting, thermal energy storage in molten salts followed by a Rankine cycle for electricity production and a multiple-effect distillation (MED) unit for desalination.

  4. A guideline for interpersonal capabilities enhancement to support sustainable facility management practice

    NASA Astrophysics Data System (ADS)

    Sarpin, Norliana; Kasim, Narimah; Zainal, Rozlin; Noh, Hamidun Mohd

    2018-04-01

    Facility management is the key phase in the development cycle of an assets and spans over a considerable length of time. Therefore, facility managers are in a commanding position to maximise the potential of sustainability through the development phases from construction, operation, maintenance and upgrade leading to decommission and deconstruction. Sustainability endeavours in facility management practices will contribute to reducing energy consumption, waste and running costs. Furthermore, it can also help in improving organisational productivity, financial return and community standing of the organisation. Facility manager should be empowered with the necessary knowledge and capabilities at the forefront facing sustainability challenge. However, literature studies show a gap between the level of awareness, specific knowledge and the necessary skills required to pursue sustainability in the facility management professional. People capability is considered as the key enabler in managing the sustainability agenda as well as being central to the improvement of competency and innovation in an organisation. This paper aims to develop a guidelines for interpersonal capabilities to support sustainability in facility management practice. Starting with a total of 7 critical interpersonal capabilities factors identified from previous questionnaire survey, the authors conducted an interview with 3 experts in facility management to assess the perceived importance of these factors. The findings reveal a set of guidelines for the enhancement of interpersonal capabilities among facility managers by providing what can be done to acquire these factors and how it can support the application of sustainability in their practice. The findings of this paper are expected to form the basis of a mechanism framework developed to equip facility managers with the right knowledge, to continue education and training and to develop new mind-sets to enhance the implementation of sustainability

  5. Filmless PACS in a multiple facility environment

    NASA Astrophysics Data System (ADS)

    Wilson, Dennis L.; Glicksman, Robert A.; Prior, Fred W.; Siu, Kai-Yeung; Goldburgh, Mitchell M.

    1996-05-01

    A Picture Archiving and Communication System centered on a shared image file server can support a filmless hospital. Systems based on this architecture have proven themselves in over four years of clinical operation. Changes in healthcare delivery are causing radiology groups to support multiple facilities for remote clinic support and consolidation of services. There will be a corresponding need for communicating over a standardized wide area network (WAN). Interactive workflow, a natural extension to the single facility case, requires a means to work effectively and seamlessly across moderate to low speed communication networks. Several schemes for supporting a consortium of medical treatment facilities over a WAN are explored. Both centralized and distributed database approaches are evaluated against several WAN scenarios. Likewise, several architectures for distributing image file servers or buffers over a WAN are explored, along with the caching and distribution strategies that support them. An open system implementation is critical to the success of a wide area system. The role of the Digital Imaging and Communications in Medicine (DICOM) standard in supporting multi- facility and multi-vendor open systems is also addressed. An open system can be achieved by using a DICOM server to provide a view of the system-wide distributed database. The DICOM server interface to a local version of the global database lets a local workstation treat the multiple, distributed data servers as though they were one local server for purposes of examination queries. The query will recover information about the examination that will permit retrieval over the network from the server on which the examination resides. For efficiency reasons, the ability to build cross-facility radiologist worklists and clinician-oriented patient folders is essential. The technologies of the World-Wide-Web can be used to generate worklists and patient folders across facilities. A reliable broadcast

  6. The LBM program at the EPFL/LOTUS Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    File, J.; Jassby, D.L.; Tsang, F.Y.

    1986-11-01

    An experimental program of neutron transport studies of the Lithium Blanket Module (LBM) is being carried out with the LOTUS point-neutron source facility at Ecole Polytechnique Federale de Lausanne (EPFL), Switzerland. Preliminary experiments use passive neutron dosimetry within the fuel rods in the LBM central zone, as well as, both thermal extraction and dissolution methods to assay tritium bred in Li/sub 2/O diagnostic wafers and LBM pellets. These measurements are being compared and reconciled with each other and with the predictions of two-dimensional discrete-ordinates and continuous-energy Monte-Carlo analyses of the Lotus/LBM system.

  7. Referral of children seeking care at private health facilities in Uganda.

    PubMed

    Mbonye, Anthony K; Buregyeya, Esther; Rutebemberwa, Elizeus; Clarke, Siân E; Lal, Sham; Hansen, Kristian S; Magnussen, Pascal; LaRussa, Philip

    2017-02-14

    In Uganda, referral of sick children seeking care at public health facilities is poor and widely reported. However, studies focusing on the private health sector are scanty. The main objective of this study was to assess referral practices for sick children seeking care at private health facilities in order to explore ways of improving treatment and referral of sick children in this sector. A survey was conducted from August to October 2014 in Mukono district, central Uganda. Data was collected using a structured questionnaire supplemented by Focus Group Discussions and Key Informant interviews with private providers and community members. A total of 241 private health facilities were surveyed; 170 (70.5%) were registered drug shops, 59 (24.5%) private clinics and 12 (5.0%) pharmacies. Overall, 104/241 (43.2%) of the private health facilities reported that they had referred sick children to higher levels of care in the two weeks prior to the survey. The main constraints to follow referral advice as perceived by caretakers were: not appreciating the importance of referral, gender-related decision-making and negotiations at household level, poor quality of care at referral facilities, inadequate finances at household level; while the perception that referral leads to loss of prestige and profit was a major constraint to private providers. In conclusion, the results show that referral of sick children at private health facilities faces many challenges at provider, caretaker, household and community levels. Thus, interventions to address constraints to referral of sick children are urgently needed.

  8. Back-Up Generator Facility and Associated Project Environmental Assessment Dyess Air Force Base, Texas

    DTIC Science & Technology

    2007-07-01

    waste, or solid waste management would be expected with implementation of the no-action alternative. Soils and Water. Impacts to soils and water...resources would be negligible. Construction would disturb about 2.5 acres, but best management practices such as silt fencing and soil surface watering...Intergovernmental Coordination for Environmental Planning tpy U.S. tons per year United States IWMP Integrated Waste Management Plan USACE United States

  9. Volatilization of PM2.5 Inorganic Ions in a Filter Pack System with Backup Filter and Denuders

    NASA Astrophysics Data System (ADS)

    Kim, C.; Choi, Y.; Ghim, Y.

    2012-12-01

    Concentrations of PM2.5 inorganic ions were measured at the rooftop of the 5-story building on the hill (37.02oN, 127.16oE, 167 m above sea level) in the Global Campus of Hankuk University of Foreign Studies, about 35 km southeast of downtown Seoul, Korea. The measurements were made four times during one-year span between 2011 and 2012 by considering the climate of Korea with distinct seasonal variations: July 29 to August 26 (summer); September 14 to October 13 (fall); November 28 to January 4 (winter); February 14 to May 31 (spring). A filter pack system was composed of PM2.5 cyclone, two annular denuders, Teflon filter, nylon filter, and an annular denuder, in series. Two annular denuders were to remove acidic and basic gases prior to collecting particles on the Teflon filter. Nylon filter and an annular denuder were to back up the Teflon filter by absorbing acidic and basic gases, respectively, which were volatilized from collected particles on the Teflon filter. Samplings were made for 24 hours every day. Extracts from filters and denuders were analyzed by ion chromatography to measure concentrations of anions (SO42-, NO3-, Cl-) and cations (Ca2+, Mg2+, NH4+, Na+, K+). The amounts of ionic species absorbed at the backup nylon filter and denuder were examined in terms of meteorological parameters, the amounts of gases removed in front of the Teflon filter, and the amounts of particulate ions collected on the Teflon filter. Major factors to affect the volatilization from particles collected on the Teflon filter were discussed.

  10. Comprehensive Software Simulation on Ground Power Supply for Launch Pads and Processing Facilities at NASA Kennedy Space Center

    NASA Technical Reports Server (NTRS)

    Dominguez, Jesus A.; Victor, Elias; Vasquez, Angel L.; Urbina, Alfredo R.

    2017-01-01

    A multi-threaded software application has been developed in-house by the Ground Special Power (GSP) team at NASA Kennedy Space Center (KSC) to separately simulate and fully emulate all units that supply VDC power and battery-based power backup to multiple KSC launch ground support systems for NASA Space Launch Systems (SLS) rocket.

  11. A Worldwide Web-portal for Aquatic Mesocosm Facilities: WWW.MESOCOSM.EU

    NASA Astrophysics Data System (ADS)

    Berger, S. A.; Nejstgaard, J. C.

    2016-02-01

    Experimental mesocosms are valuable tools to fill the gap between highly controlled/replicated lab experiments and uncontrolled/non-replicated natural environments such as rivers, lakes and oceans. WWW.MESOCOSM.EU is an open web-portal for leading aquatic mesocosm facilities around the world. It was created within the FP7 EU-project MESOAQUA (A network of leading MESOcosm facilities to advance the studies of future AQUAtic ecosystems from the Arctic to the Mediterranean). The goal of the portal is to increase international knowledge about existing mesocosm facilities, including information on locations, environment, equipment, contacts, research opportunities and mesocosm-based publications. MESOCOSM.EU specifically aims to be a tool to enhance the quality of research by facilitating international cooperative network building, announcement of new research initiatives, transfer of best practice, and dissemination of knowledge, public information and press releases. As an open platform for all aquatic ecosystem scale science (marine and freshwater), MESOCOSM.EU aims to fill the lack of a centralized, coordinating virtual infrastructure for international aquatic mesocosm research, from the mountains to the ocean and from polar to tropical regions.

  12. STS-46 crewmembers during water egress training in JSC's WETF Bldg 29

    NASA Technical Reports Server (NTRS)

    1992-01-01

    STS-46 Atlantis, Orbiter Vehicle (OV) 104, European Space Agency (ESA) Mission Specialist (MS) Claude Nicollier (left) and backup Italian Payload Specialist Umberto Guidoni, seated at the pool's side, relax before participating in a launch emergency egress (bailout) simulation in JSC's Weightless Environment Training Facility (WETF) Bldg 29. The two participants are wearing launch and entry suits (LESs) during the pretest briefing.

  13. Facilities Performance Indicators Report 2013-14: Tracking Your Facilities Vital Signs

    ERIC Educational Resources Information Center

    APPA: Association of Higher Education Facilities Officers, 2015

    2015-01-01

    This paper features an expanded Web-based "Facilities Performance Indicators (FPI) Report." The purpose of APPA: Association of Higher Education Facilities Officers (APPA's) Facilities Performance Indicators is to provide a representative set of statistics about facilities in educational institutions. "The Facilities Performance…

  14. HANFORD SITE CENTRAL PLATEAU CLEANUP COMPLETION STRATEGY

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    BERGMAN TB

    2011-01-14

    Cleanup of the Hanford Site is a complex and challenging undertaking. The U.S. Department of Energy (DOE) has developed a comprehensive vision for completing Hanford's cleanup mission including transition to post-cleanup activities. This vision includes 3 principle components of cleanup: the {approx}200 square miles ofland adjacent to the Columbia River, known as the River Corridor; the 75 square miles of land in the center of the Hanford Site, where the majority of the reprocessing and waste management activities have occurred, known as the Central Plateau; and the stored reprocessing wastes in the Central Plateau, the Tank Wastes. Cleanup of themore » River Corridor is well underway and is progressing towards completion of most cleanup actions by 2015. Tank waste cleanup is progressing on a longer schedule due to the complexity of the mission, with construction of the largest nuclear construction project in the United States, the Waste Treatment Plant, over 50% complete. With the progress on the River Corridor and Tank Waste, it is time to place increased emphasis on moving forward with cleanup of the Central Plateau. Cleanup of the Hanford Site has been proceeding under a framework defmed in the Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement). In early 2009, the DOE, the State of Washington Department of Ecology, and the U.S. Environmental Protection Agency signed an Agreement in Principle in which the parties recognized the need to develop a more comprehensive strategy for cleanup of the Central Plateau. DOE agreed to develop a Central Plateau Cleanup Completion Strategy as a starting point for discussions. This DOE Strategy was the basis for negotiations between the Parties, discussions with the State of Oregon, the Hanford Advisory Board, and other Stakeholder groups (including open public meetings), and consultation with the Tribal Nations. The change packages to incorporate the Central Plateau Cleanup Completion Strategy were

  15. Improving water, sanitation and hygiene in health-care facilities, Liberia

    PubMed Central

    Montgomery, Maggie; Baller, April; Ndivo, Francis; Gasasira, Alex; Cooper, Catherine; Frescas, Ruben; Gordon, Bruce; Syed, Shamsuzzoha Babar

    2017-01-01

    Abstract Problem The lack of proper water and sanitation infrastructures and poor hygiene practices in health-care facilities reduces facilities’ preparedness and response to disease outbreaks and decreases the communities’ trust in the health services provided. Approach To improve water and sanitation infrastructures and hygiene practices, the Liberian health ministry held multistakeholder meetings to develop a national water, sanitation and hygiene and environmental health package. A national train-the-trainer course was held for county environmental health technicians, which included infection prevention and control focal persons; the focal persons acted as change agents. Local setting In Liberia, only 45% of 701 surveyed health-care facilities had an improved water source in 2015, and only 27% of these health-care facilities had proper disposal for infectious waste. Relevant changes Local ownership, through engagement of local health workers, was introduced to ensure development and refinement of the package. In-county collaborations between health-care facilities, along with multisectoral collaboration, informed national level direction, which led to increased focus on water and sanitation infrastructures and uptake of hygiene practices to improve the overall quality of service delivery. Lessons learnt National level leadership was important to identify a vision and create an enabling environment for changing the perception of water, sanitation and hygiene in health-care provision. The involvement of health workers was central to address basic infrastructure and hygiene practices in health-care facilities and they also worked as stimulators for sustainable change. Further, developing a long-term implementation plan for national level initiatives is important to ensure sustainability. PMID:28670017

  16. Defining skilled nursing facility residents' dining style preferences.

    PubMed

    Adams, Katy; Anderson, Janet B; Archuleta, Martha; Smith Kudin, Janette

    2013-01-01

    The desire of skilled nursing facilities to increase quality of service to meet changes in residents' expectations, improve marketability, and adhere to regulations warrant a new look at culture change and homelike dining as defined by residents in skilled nursing facilities (SNF). The objectives of this study were to determine residents' home dining practices, to define residents' desired dining style practices in the SNF, and to determine the relationship between home dining practices and dining preferences in SNF. One hundred and four residents in three SNF in the central Texas area who met the cognition criteria and consumed facility-provided food were engaged in a standardized interview using the Resident Dining Style Preferences Survey. Data were analyzed to determine the degree to which home practices determine SNF dining preferences. Our findings showed that the majority of the participants want hot, home cooked meals served in the dining room. They want to be seated at the table with friends and neighbors and served on every day plates in a quiet atmosphere, with food served restaurant or table service style. Length of stay and generational group were not significant predictors of dining style preferences. Study limitations included small sample size and lack of ethnic diversity. Our study results show that removing dining time restrictions may be the most valuable adaptation for a SNF looking to initiate culture change.

  17. Feasibility study of the solar scientific instruments for Spacelab/Orbiter

    NASA Technical Reports Server (NTRS)

    Leritz, J.; Rasser, T.; Stone, E.; Lockhart, B.; Nobles, W.; Parham, J.; Eimers, D.; Peterson, D.; Barnhart, W.; Schrock, S.

    1981-01-01

    The feasibility and economics of mounting and operating a set of solar scientific instruments in the backup Skylab Apollo Telescope Mount (ATM) hardware was evaluated. The instruments used as the study test payload and integrated into the ATM were: the Solar EUV Telescope/Spectrometer; the Solar Active Region Observing Telescope; and the Lyman Alpha White Light Coronagraph. The backup ATM hardware consists of a central cruciform structure, called the "SPAR', a "Sun End Canister' and a "Multiple Docking Adapter End Canister'. Basically, the ATM hardware and software provides a structural interface for the instruments; a closely controlled thermal environment; and a very accurate attitude and pointing control capability. The hardware is an identical set to the hardware that flow on Skylab.

  18. STS-45 backup Payload Specialist Chappell during water egress training at JSC

    NASA Image and Video Library

    1991-11-26

    S91-52074 (26 Nov 1991) --- Charles R. (Rick) Chappell, alternate payload specialist, equipped with simulated parachute gear, descends into the water during bail-out training exercises in the Johnson Space Center's weightless environment training facility (WET-F). In this phase of the training program, Shuttle crewmembers learn the proper measures to take in the event of ejection and subsequent parachute landing into a body of water. A number of SCUBA-equipped swimmers who assisted in the training are pictured.

  19. Facilities maintenance handbook

    NASA Technical Reports Server (NTRS)

    1991-01-01

    This handbook is a guide for facilities maintenance managers. Its objective is to set minimum facilities maintenance standards. It also provides recommendations on how to meet the standards to ensure that NASA maintains its facilities in a manner that protects and preserves its investment in the facilities in a cost-effective manner while safely and efficiently performing its mission. This handbook implements NMI 8831.1, which states NASA facilities maintenance policy and assigns organizational responsibilities for the management of facilities maintenance activities on all properties under NASA jurisdiction. It is a reference for facilities maintenance managers, not a step-by-step procedural manual. Because of the differences in NASA Field Installation organizations, this handbook does not assume or recommend a typical facilities maintenance organization. Instead, it uses a systems approach to describe the functions that should be included in any facilities maintenance management system, regardless of its organizational structure. For documents referenced in the handbook, the most recent version of the documents is applicable. This handbook is divided into three parts: Part 1 specifies common definitions and facilities maintenance requirements and amplifies the policy requirements contained in NMI 8831. 1; Part 2 provides guidance on how to meet the requirements of Part 1, containing recommendations only; Part 3 contains general facilities maintenance information. One objective of this handbook is to fix commonality of facilities maintenance definitions among the Centers. This will permit the application of uniform measures of facilities conditions, of the relationship between current replacement value and maintenance resources required, and of the backlog of deferred facilities maintenance. The utilization of facilities maintenance system functions will allow the Centers to quantitatively define maintenance objectives in common terms, prepare work plans, and

  20. Development of the Plant Growth Facility for Use in the Shuttle Middeck and Test Units for Ground-Based Experiments

    NASA Technical Reports Server (NTRS)

    Chapman, David K.; Wells, H. William

    1996-01-01

    The plant growth facility (PGF), currently under development as a Space Shuttle middeck facility for the support of research on higher plants in microgravity, is presented. The PGF provides controlled fluorescent lighting and the active control of temperature, relative humidity and CO2 concentration. These parameters are designed to be centrally controlled by a dedicated microprocessor. The status of the experiment can be displayed for onboard analysis, and will be automatically archived for post-flight analysis. The facility is designed to operate for 15 days and will provide air filtration to remove ethylene and trace organics with replaceable potassium permanganate filters. Similar ground units will be available for pre-flight experimentation.

  1. TACS Central Control Facility.

    DTIC Science & Technology

    1981-02-12

    PULSE RTC REAL TIME CLOCK -{> I . SIGNAL INVERSION UASC UNIVERSAL ASYNCHRONOUS SERIAL - ---- 4w SPECIAL INTERFACE CONTROLLER Fiq. 2-1. MAC hardware...34 Universal Asynchronous Serial Controller" (UASC) cards. The cards implement an RS-232 standard interface. All controllers are set to operate at a data...Bridwell and I. Richer, "A Preliminary Design of a TDMA System for FLEETSAT," Technical Note 1975-5, Lincoln Laboratory, M.I.T. (12 March 1975), DDC

  2. Facilities Performance Indicators Report, 2004-05. Facilities Core Data Survey

    ERIC Educational Resources Information Center

    Glazner, Steve, Ed.

    2006-01-01

    The purpose of "Facilities Performance Indicators" is to provide a representative set of statistics about facilities in educational institutions. The second iteration of the web-based Facilities Core Data Survey was posted and available to facilities professionals at more than 3,000 institutions in the Fall of 2005. The website offered a printed…

  3. Central and Eastern United States (CEUS) Seismic Source Characterization (SSC) for Nuclear Facilities Project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kevin J. Coppersmith; Lawrence A. Salomone; Chris W. Fuller

    2012-01-31

    This report describes a new seismic source characterization (SSC) model for the Central and Eastern United States (CEUS). It will replace the Seismic Hazard Methodology for the Central and Eastern United States, EPRI Report NP-4726 (July 1986) and the Seismic Hazard Characterization of 69 Nuclear Plant Sites East of the Rocky Mountains, Lawrence Livermore National Laboratory Model, (Bernreuter et al., 1989). The objective of the CEUS SSC Project is to develop a new seismic source model for the CEUS using a Senior Seismic Hazard Analysis Committee (SSHAC) Level 3 assessment process. The goal of the SSHAC process is to representmore » the center, body, and range of technically defensible interpretations of the available data, models, and methods. Input to a probabilistic seismic hazard analysis (PSHA) consists of both seismic source characterization and ground motion characterization. These two components are used to calculate probabilistic hazard results (or seismic hazard curves) at a particular site. This report provides a new seismic source model. Results and Findings The product of this report is a regional CEUS SSC model. This model includes consideration of an updated database, full assessment and incorporation of uncertainties, and the range of diverse technical interpretations from the larger technical community. The SSC model will be widely applicable to the entire CEUS, so this project uses a ground motion model that includes generic variations to allow for a range of representative site conditions (deep soil, shallow soil, hard rock). Hazard and sensitivity calculations were conducted at seven test sites representative of different CEUS hazard environments. Challenges and Objectives The regional CEUS SSC model will be of value to readers who are involved in PSHA work, and who wish to use an updated SSC model. This model is based on a comprehensive and traceable process, in accordance with SSHAC guidelines in NUREG/CR-6372, Recommendations for

  4. MyOcean Central Information System - Achievements and Perspectives

    NASA Astrophysics Data System (ADS)

    Claverie, Vincent; Loubrieu, Thomas; Jolibois, Tony; de Dianous, Rémi; Blower, Jon; Romero, Laia; Griffiths, Guy

    2013-04-01

    Since 2009, MyOcean (http://www.myocean.eu) is providing an operational service, for forecasts, analysis and expertise on ocean currents, temperature, salinity, sea level, primary ecosystems and ice coverage. The production of observation and forecasting data is done by 42 Production Units (PU). Product download and visualisation are hosted by 25 Dissemination Units (DU). All these products and associated services are gathered in a single catalogue hiding the intricate distributed organization of PUs and DUs. Besides applying INSPIRE directive and OGC recommendations, MyOcean overcomes technical choices and challenges. This presentation focuses on 3 specific issues met by MyOcean and relevant for many Spatial Data Infrastructures: user's transaction accounting, large volume download and stream line the catalogue maintenance. Transaction Accounting: Set up powerful means to get detailed knowledge of system usage in order to subsequently improve the products (ocean observations, analysis and forecast dataset) and services (view, download) offer. This subject drives the following ones: Central authentication management for the distributed web services implementations: add-on to THREDDS Data Server for WMS and NETCDF sub-setting service, specific FTP. Share user management with co-funding projects. In addition to MyOcean, alternate projects also need consolidated information about the use of the cofunded products. Provide a central facility for the user management. This central facility provides users' rights to geographically distributed services and gathers transaction accounting history from these distributed services. Propose a user-friendly web interface to download large volume of data (several GigaBytes) as robust as basic FTP but intuitive and file/directory independent. This should rely on a web service drafting the INSPIRE to-be specification and OGC recommendations for download taking into account that FTP server is not enough friendly (need to know

  5. The 10 MWe solar thermal central receiver pilot plant solar facilities design integration, RADL item 1-10

    NASA Astrophysics Data System (ADS)

    1980-07-01

    Accomplishments are reported in the areas of: program management, system integration, the beam characterization system, receiver unit, thermal storage subsystems, master control system, plant support subsystem and engineering services. A solar facilities design integration program action items update is included. Work plan changes and cost underruns are discussed briefly. (LEW)

  6. Pinon-juniper management research at Corona Range and Livestock Research Center in Central New Mexico

    Treesearch

    Andres Cibils; Mark Petersen; Shad Cox; Michael Rubio

    2008-01-01

    Description: New Mexico State University's Corona Range and Livestock Research Center (CRLRC) is located in a pinon-juniper (PJ)/grassland ecotone in the southern Basin and Range Province in south central New Mexico. A number of research projects conducted at this facility revolve around soil, plant, livestock, and wildlife responses to PJ woodland management. The...

  7. NASA Wallops Flight Facility Air-Sea Interaction Research Facility

    NASA Technical Reports Server (NTRS)

    Long, Steven R.

    1992-01-01

    This publication serves as an introduction to the Air-Sea Interaction Research Facility at NASA/GSFC/Wallops Flight Facility. The purpose of this publication is to provide background information on the research facility itself, including capabilities, available instrumentation, the types of experiments already done, ongoing experiments, and future plans.

  8. Implementation of tuberculosis infection prevention and control in Mozambican health care facilities.

    PubMed

    Brouwer, M; Coelho, E; das Dores Mosse, C; van Leth, F

    2015-01-01

    District and urban health care facilities in three provinces (Manica, Sofala, Tete) in central Mozambique. To assess the level of implementation of selected tuberculosis infection prevention and control (TB-IPC) measures. In a cross-sectional study of TB-IPC implementation in 29 health care facilities, we assessed TB clinics, laboratories, out-patient departments and medical and TB wards. Assessment included selected managerial, administrative and environmental measures and the availability and use of respiratory protective equipment (N95 respirators). Guidelines for diagnosis and treatment of (presumptive) TB patients were not present in all facilities. Staff instructed patients on sputum collection in 91%, but only 4% observed it. Using a pragmatic '20% rule', 52% of the rooms assessed had adequate ventilation. Potentially, this could be increased to 76%. Three quarters of the health care workers had N95 respirators. Only 36% knew how to use it correctly. Implementation of TB-IPC measures showed wide variations within health care facilities. Relatively simple measures to improve TB-IPC include the availability of guidelines, opening doors and windows to improve ventilation, and training and support on correct N95 respirator use. However, even relatively simple measures are challenging to implement, and require careful attention in and evaluation of the implementation process.

  9. Facilities Performance Indicators Report 2012-13: Tracking Your Facilities Vital Signs

    ERIC Educational Resources Information Center

    APPA: Association of Higher Education Facilities Officers, 2014

    2014-01-01

    This paper features an expanded Web-based "Facilities Performance Indicators (FPI) Report." The purpose of APPA's Facilities Performance Indicators is to provide a representative set of statistics about facilities in educational institutions. "The Facilities Performance Indicators Report" is designed for survey…

  10. Planning and Designing Facilities. Facility Design and Development--Part 1

    ERIC Educational Resources Information Center

    Hypes, Michael G.

    2006-01-01

    Before one begins the planning process for a new facility, it is important to determine if there is a need for a new facility. The demand for a new facility can be drawn from increases in the number of users, the type of users, and the type of events to be conducted in the facility. A feasibility study should be conducted to analyze the legal…

  11. Earth and water resources and hazards in Central America

    USGS Publications Warehouse

    Cunningham, Charles G.; Fary, R.W.; Guffanti, Marianne; Laura, Della; Lee, M.P.; Masters, C.D.; Miller, R.L.; Quinones-Marques, Ferdinand; Peebles, R.W.; Reinemund, J.A.; Russ, D.P.

    1984-01-01

    Long-range economic development in Central America will depend in large part on production of indigenous mineral, energy, and water resources and on mitigation of the disastrous effects of geologic and hydrologic hazards such as landslides, earthquakes, volcanic eruptions, and floods. The region has six world-class metal mines at present as well as additional evidence of widespread mineralization. Systematic investigations using modern mineral exploration techniques should reveal more mineral deposits suitable for development. Widespread evidence of lignite and geothermal resources suggests that intensive studies could identify producible energy sources in most Central American countries. Water supply and water quality vary greatly from country to country. Local problems of ground- and surface-water availability and of contamination create a need for systematic programs to provide better hydrologic data, capital improvements, and management. Disastrous earthquakes have destroyed or severely damaged many cities in Central America. Volcanic eruptions, landslides, mudflows, and floods have devastated most of the Pacific side of Central America at one time or another. A regional approach to earthquake, volcano, and flood-risk analysis and monitoring, using modern technology and concepts, would provide the facilities and means for acquiring knowledge necessary to reduce future losses. All Central American countries need to strengthen institutions and programs dealing with earth and water resources and natural hazards. Some of these needs may be satisfied through existing or pending projects and technical and economic assistance from U.S. or other sources. The need for a comprehensive study of the natural resources of Central America and the requirements for their development is evident. The U.S. Caribbean Basin Initiative offers both an excellent opportunity for a regional approach to these pervasive problems and an opportunity for international cooperation.

  12. 18. Topside facility, interior of facility manager's room, view towards ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    18. Topside facility, interior of facility manager's room, view towards west. Lyon - Whiteman Air Force Base, Oscar O-1 Minuteman Missile Alert Facility, Southeast corner of Twelfth & Vendenberg Avenues, Knob Noster, Johnson County, MO

  13. Experimental Fuels Facility Re-categorization Based on Facility Segmentation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reiss, Troy P.; Andrus, Jason

    The Experimental Fuels Facility (EFF) (MFC-794) at the Materials and Fuels Complex (MFC) located on the Idaho National Laboratory (INL) Site was originally constructed to provide controlled-access, indoor storage for radiological contaminated equipment. Use of the facility was expanded to provide a controlled environment for repairing contaminated equipment and characterizing, repackaging, and treating waste. The EFF facility is also used for research and development services, including fuel fabrication. EFF was originally categorized as a LTHC-3 radiological facility based on facility operations and facility radiological inventories. Newly planned program activities identified the need to receive quantities of fissionable materials in excessmore » of the single parameter subcritical limit in ANSI/ANS-8.1, “Nuclear Criticality Safety in Operations with Fissionable Materials Outside Reactors” (identified as “criticality list” quantities in DOE-STD-1027-92, “Hazard Categorization and Accident Analysis Techniques for Compliance with DOE Order 5480.23, Nuclear Safety Analysis Reports,” Attachment 1, Table A.1). Since the proposed inventory of fissionable materials inside EFF may be greater than the single parameter sub-critical limit of 700 g of U-235 equivalent, the initial re-categorization is Hazard Category (HC) 2 based upon a potential criticality hazard. This paper details the facility hazard categorization performed for the EFF. The categorization was necessary to determine (a) the need for further safety analysis in accordance with LWP-10802, “INL Facility Categorization,” and (b) compliance with 10 Code of Federal Regulations (CFR) 830, Subpart B, “Safety Basis Requirements.” Based on the segmentation argument presented in this paper, the final hazard categorization for the facility is LTHC-3. Department of Energy Idaho (DOE-ID) approval of the final hazard categorization determined by this hazard assessment document (HAD) was required

  14. Midcourse Space Experiment (MSX)

    DTIC Science & Technology

    1992-08-01

    Facility (PCF), on South Base. The PPF houses the MSX spacecraft for the prelaunch operations (installation of payload fairing, battery charging , etc...include: unpacking the spacecraft from its shipping container; charging the onboard nickel-hydrogen batteries ; filling the cryostat with solid...activities, and will remain in orbit for several hundred years. The MSX spacecraft is solar powered with a battery backup. The battery is capable of

  15. Piloted Simulation Tests of Propulsion Control as Backup to Loss of Primary Flight Controls for a B747-400 Jet Transport

    NASA Technical Reports Server (NTRS)

    Bull, John; Mah, Robert; Hardy, Gordon; Sullivan, Barry; Jones, Jerry; Williams, Diane; Soukup, Paul; Winters, Jose

    1997-01-01

    Partial failures of aircraft primary flight control systems and structural damages to aircraft during flight have led to catastrophic accidents with subsequent loss of lives (e.g. DC-10, B-747, C-5, B-52, and others). Following the DC-10 accident at Sioux City, Iowa in 1989, the National Transportation Safety Board recommended 'Encourage research and development of backup flight control systems for newly certified wide-body airplanes that utilize an alternate source of motive power separate from that source used for the conventional control system.' This report describes the concept of a propulsion controlled aircraft (PCA), discusses pilot controls, displays, and procedures; and presents the results of a PCA piloted simulation test and evaluation of the B747-400 airplane conducted at NASA Ames Research Center in December, 1996. The purpose of the test was to develop and evaluate propulsion control throughout the full flight envelope of the B747-400 including worst case scenarios of engine failures and out of trim moments. Pilot ratings of PCA performance ranged from adequate to satisfactory. PCA performed well in unusual attitude recoveries at 35,000 ft altitude, performed well in fully coupled ILS approaches, performed well in single engine failures, and performed well at aft cg. PCA performance was primarily limited by out-of-trim moments.

  16. Hanford Facility dangerous waste permit application, liquid effluent retention facility and 200 area effluent treatment facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Coenenberg, J.G.

    1997-08-15

    The Hanford Facility Dangerous Waste Permit Application is considered to 10 be a single application organized into a General Information Portion (document 11 number DOE/RL-91-28) and a Unit-Specific Portion. The scope of the 12 Unit-Specific Portion is limited to Part B permit application documentation 13 submitted for individual, `operating` treatment, storage, and/or disposal 14 units, such as the Liquid Effluent Retention Facility and 200 Area Effluent 15 Treatment Facility (this document, DOE/RL-97-03). 16 17 Both the General Information and Unit-Specific portions of the Hanford 18 Facility Dangerous Waste Permit Application address the content of the Part B 19 permit applicationmore » guidance prepared by the Washington State Department of 20 Ecology (Ecology 1987 and 1996) and the U.S. Environmental Protection Agency 21 (40 Code of Federal Regulations 270), with additional information needs 22 defined by the Hazardous and Solid Waste Amendments and revisions of 23 Washington Administrative Code 173-303. For ease of reference, the Washington 24 State Department of Ecology alpha-numeric section identifiers from the permit 25 application guidance documentation (Ecology 1996) follow, in brackets, the 26 chapter headings and subheadings. A checklist indicating where information is 27 contained in the Liquid Effluent Retention Facility and 200 Area Effluent 28 Treatment Facility permit application documentation, in relation to the 29 Washington State Department of Ecology guidance, is located in the Contents 30 Section. 31 32 Documentation contained in the General Information Portion is broader in 33 nature and could be used by multiple treatment, storage, and/or disposal units 34 (e.g., the glossary provided in the General Information Portion). Wherever 35 appropriate, the Liquid Effluent Retention Facility and 200 Area Effluent 36 Treatment Facility permit application documentation makes cross-reference to 37 the General Information Portion, rather than

  17. Political economy of decentralising HIV and AIDS treatment services to primary healthcare facilities in three Nigerian states.

    PubMed

    Mbachu, Chinyere; Onwujekwe, Obinna; Ezumah, Nkoli; Ajayi, Olayinka; Sanwo, Olusola; Uzochukwu, Benjamin

    2016-09-01

    Decentralisation is defined as the dispersion, distribution or transfer of resources, functions and decision-making power from a central authority to regional and local authorities. It is usually accompanied by assignment of accountability and responsibility for results. Fundamental to understanding decentralisation is learning what motivates central governments to give up power and resources to local governments, and the practical significance of this on their positions regarding decentralisation. This study examined key political and institutional influences on role-players' capacity to support decentralisation of HIV and AIDS treatment services to primary healthcare facilities, and implications for sustainability. In-depth interviews were conducted with 55 purposively selected key informants, drawn from three Nigerian states that were at different stages of decentralising HIV and AIDS treatment services to primary care facilities. Key informants represented different categories of role-players involved in HIV and AIDS control programmes. Thematic framework analysis of data was done. Support for decentralisation of HIV and AIDS treatment services to primary healthcare facilities was substantial among different categories of actors. Political factors such as the local and global agenda for health, political tenure and party affiliations, and institutional factors such as consolidation of decision-making power and improvements in career trajectories, influenced role-players support for decentralisation of HIV and AIDS treatment services. It is feasible and acceptable to decentralise HIV and AIDS treatment services to primary healthcare facilities, to help improve coverage. However, role-players' support largely depends on how well the reform aligns with political structures and current institutional practices.

  18. Enhancing Military-Civilian Medical Synergies: The Role of Army Medical Practice in Civilian Facilities

    DTIC Science & Technology

    2016-01-01

    medical service (such as obstetric delivery), or a specific technology (such as robotic surgery apparatus), is not available at the MTF. All 13...operating theaters and lack of robotic surgery capabilities at WBAMC. We found three relevant agreements in the MEDCOM central repository...civilian facilities offer was superior to what was available (and justifiable) at the MTF—notably, robotic surgery capa- bility. Not only do these

  19. Virtual Planning at Work: A Tour of NASA Future Flight Central

    NASA Technical Reports Server (NTRS)

    McClenahen, Jim; Dorighi, Nancy S. (Technical Monitor)

    2000-01-01

    FutureFlight Central will permit integration of tomorrow's technologies in a risk-free simulation of any airport, airfield, and tower cab environment. The facility provides an opportunity for airlines to mitigate passenger delays by fine tuning airport hub operations, gate management and ramp movement procedures. It also allows airport managers an opportunity to study effects of various improvements at their airports. Finally, it enables air traffic controllers to provide feedback and to become familiar with new airport operations and technologies before final installation.

  20. Lead in drinking water: sampling in primary schools and preschools in south central Kansas.

    PubMed

    Massey, Anne R; Steele, Janet E

    2012-03-01

    Studies in Philadelphia, New York City, Houston, Washington, DC, and Greenville, North Carolina, have revealed high lead levels in drinking water. Unlike urban areas, lead levels in drinking water in suburban and rural areas have not been adequately studied. In the study described in this article, drinking water in primary schools and preschools in five suburban and rural south central Kansas towns was sampled to determine if any exceeded the U.S. Environmental Protection Agency (U.S. EPA) guidance level for schools and child care facilities of 20 parts per billion (ppb). The results showed a total of 32.1% of the samples had detectable lead levels and 3.6% exceeded the U.S. EPA guidance level for schools and child care providers of 20 ppb. These results indicate that about one-third of the drinking water consumed by children age six and under in the five suburban and rural south central Kansas towns studied has some lead contamination, exposing these children to both short-term and long-term health risks. The authors suggest a need for increased surveillance of children's drinking water in these facilities.

  1. FACILITY 846, SOUTHEAST END ON LEFT, WITH FACILITY 845 ON ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    FACILITY 846, SOUTHEAST END ON LEFT, WITH FACILITY 845 ON RIGHT AND FACILITY 847 IN CENTER BACKGROUND, QUADRANGLE J, VIEW FACING NORTH. - Schofield Barracks Military Reservation, Quadrangles I & J Barracks Type, Between Wright-Smith & Capron Avenues near Williston Avenue, Wahiawa, Honolulu County, HI

  2. Facilities | Bioenergy | NREL

    Science.gov Websites

    Facilities Facilities At NREL's state-of-the-art bioenergy research facilities, researchers design options. Photo of interior of industrial, two-story building with high-bay, piping, and large processing

  3. KENNEDY SPACE CENTER, FLA. - KSC Director Jim Kennedy makes a presentation to NASA and other officials about the benefits of locating NASA’s new Shared Services Center in the Central Florida Research Park, near Orlando. At the far left is Pamella J. Dana, Ph.D., director, Office of Tourism, Trade, and Economic Development in Florida. Central Florida leaders are proposing the research park as the site for the NASA Shared Services Center. The center would centralize NASA’s payroll, accounting, human resources, facilities and procurement offices that are now handled at each field center. The consolidation is part of the One NASA focus. Six sites around the U.S. are under consideration by NASA.

    NASA Image and Video Library

    2004-02-19

    KENNEDY SPACE CENTER, FLA. - KSC Director Jim Kennedy makes a presentation to NASA and other officials about the benefits of locating NASA’s new Shared Services Center in the Central Florida Research Park, near Orlando. At the far left is Pamella J. Dana, Ph.D., director, Office of Tourism, Trade, and Economic Development in Florida. Central Florida leaders are proposing the research park as the site for the NASA Shared Services Center. The center would centralize NASA’s payroll, accounting, human resources, facilities and procurement offices that are now handled at each field center. The consolidation is part of the One NASA focus. Six sites around the U.S. are under consideration by NASA.

  4. A skyshine study for a low-level radwaste storage facility for state compacts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shoemaker, D.C.; Hopkins, W.C.; Jha, S.

    1989-11-01

    The Central Interstate Compact Facility, to be located in Nebraska, is designed to utilize above-grade concrete vaults for disposal of all classes of waste. Such a low-level radwaste facility (LLRWF) must meet many, and at times competing, design conditions. One of the more rigorous design conditions is to limit the yearly effluent dose and direct radiation dose to the closest resident to the facility to < 0.25 mSv (25 mrem). Thus, a shield designer must assure that the proposed design will not only be cost-effective and provide for the conventional maintenance and operations of the facility, but will also meetmore » the performance criteria. During the operational phase of the facility, the dominant dose quickly becomes the air-scattered dose (skyshine) from the photons emerging from the roofs and walls of the facility. To investigate the sensitivity to skyshine of a preliminary design for an LLRWF, a study was undertaken using a version of the MORSE Monte Carlo program that runs on a PC/386. The effects of source energy were also examined by modeling two difference sources--{sup 60}Co and {sup 137}Cs. It was felt that these two isotopes are representative of the predominant high-energy gamma emitters for the projected waste inventory in the LLRWF. At the end of the design life of the LLRWF (i.e., full capacity at 30 yr), it was found that the difference in the yearly dose between assuring all {sup 60}Co and all {sup 137}Cs was a factor of < 2.« less

  5. EPA Facility Registry Service (FRS): Facility Interests Dataset

    EPA Pesticide Factsheets

    This web feature service consists of location and facility identification information from EPA's Facility Registry Service (FRS) for all sites that are available in the FRS individual feature layers. The layers comprise the FRS major program databases, including:Assessment Cleanup and Redevelopment Exchange System (ACRES) : brownfields sites ; Air Facility System (AFS) : stationary sources of air pollution ; Air Quality System (AQS) : ambient air pollution data from monitoring stations; Bureau of Indian Affairs (BIA) : schools data on Indian land; Base Realignment and Closure (BRAC) facilities; Clean Air Markets Division Business System (CAMDBS) : market-based air pollution control programs; Comprehensive Environmental Response, Compensation, and Liability Information System (CERCLIS) : hazardous waste sites; Integrated Compliance Information System (ICIS) : integrated enforcement and compliance information; National Compliance Database (NCDB) : Federal Insecticide, Fungicide, and Rodenticide Act (FIFRA) and the Toxic Substances Control Act (TSCA); National Pollutant Discharge Elimination System (NPDES) module of ICIS : NPDES surface water permits; Radiation Information Database (RADINFO) : radiation and radioactivity facilities; RACT/BACT/LAER Clearinghouse (RBLC) : best available air pollution technology requirements; Resource Conservation and Recovery Act Information System (RCRAInfo) : tracks generators, transporters, treaters, storers, and disposers of haz

  6. Intake-to-delivered-energy ratios for central station and distributed electricity generation in California

    NASA Astrophysics Data System (ADS)

    Heath, Garvin A.; Nazaroff, William W.

    In previous work, we showed that the intake fraction (iF) for nonreactive primary air pollutants was 20 times higher in central tendency for small-scale, urban-sited distributed electricity generation (DG) sources than for large-scale, central station (CS) power plants in California [Heath, G.A., Granvold, P.W., Hoats, A.S., Nazaroff, W.W., 2006. Intake fraction assessment of the air pollutant exposure implications of a shift toward distributed electricity generation. Atmospheric Environment 40, 7164-7177]. The present paper builds on that study, exploring pollutant- and technology-specific aspects of population inhalation exposure from electricity generation. We compare California's existing CS-based system to one that is more reliant on DG units sited in urban areas. We use Gaussian plume modeling and a GIS-based exposure analysis to assess 25 existing CSs and 11 DG sources hypothetically located in the downtowns of California's most populous cities. We consider population intake of three pollutants—PM 2.5, NO x and formaldehyde—directly emitted by five DG technologies—natural gas (NG)-fired turbines, NG internal combustion engines (ICE), NG microturbines, diesel ICEs, and fuel cells with on-site NG reformers. We also consider intake of these pollutants from existing CS facilities, most of which use large NG turbines, as well as from hypothetical facilities located at these same sites but meeting California's best-available control technology standards. After systematically exploring the sensitivity of iF to pollutant decay rate, the iFs for each of the three pollutants for all DG and CS cases are estimated. To efficiently compare the pollutant- and technology-specific exposure potential on an appropriate common basis, a new metric is introduced and evaluated: the intake-to-delivered-energy ratio (IDER). The IDER expresses the mass of pollutant inhaled by an exposed population owing to emissions from an electricity generation unit per quantity of electric

  7. System design package for the solar heating and cooling central data processing system

    NASA Technical Reports Server (NTRS)

    1978-01-01

    The central data processing system provides the resources required to assess the performance of solar heating and cooling systems installed at remote sites. These sites consist of residential, commercial, government, and educational types of buildings, and the solar heating and cooling systems can be hot-water, space heating, cooling, and combinations of these. The instrumentation data associated with these systems will vary according to the application and must be collected, processed, and presented in a form which supports continuity of performance evaluation across all applications. Overall software system requirements were established for use in the central integration facility which transforms raw data collected at remote sites into performance evaluation information for assessing the performance of solar heating and cooling systems.

  8. Designing a Virtual Research Facility to motivate Professional-Citizen Collaboration

    NASA Astrophysics Data System (ADS)

    Gay, Pamela

    In order to handle the onslaught of data spilling from telescopes on the Earth and on orbit, CosmoQuest has created a virtual research facility that allows the public to collaborate with science teams on projects that would otherwise lack the necessary human resources. This second-generation citizen science site goes beyond asking people to click on images to also engaging them in taking classes, attending virtual seminars, and participating in virtual star parties. These features were introduced to try and expand the diversity of motivations that bring people to the project and to keep them engaged overtime - just as a research center seeks to bring a diversity of people together to work and learn over time. In creating the CosmoQuest Virtual Research Facility, we sought to answer the question, “What would happen if we provided the public with the same kinds of facilities scientists have, and invite them to be our collaborators?” It had already been observed that the public readily attends public science lectures, open houses at science facilities, and education programs such as star parties. It was hoped that by creating a central facility, we could build a community of people learning and doing science in a productive manner. In order to be successful, we needed to first create the facility, then test if people were coming both to learn and to do science, and finally to verify that people were doing legitimate science. During the past 18 months of operations, we have continued to work through each of these stages, as discussed talk. At this early date, progress is on-going, and much research remains to be done, but all indications show that we are on our way to building a community of people learning and doing science. During 2013-2014, a series of studies looked at the motivations of CosmoQuest users, as well as their forms of site interactions. During this talk, we will review these results, as well as the demographics of our user population.

  9. How work context affects operating room processes: using data mining and computer simulation to analyze facility and process design.

    PubMed

    Baumgart, André; Denz, Christof; Bender, Hans-Joachim; Schleppers, Alexander

    2009-01-01

    The complexity of the operating room (OR) requires that both structural (eg, department layout) and behavioral (eg, staff interactions) patterns of work be considered when developing quality improvement strategies. In our study, we investigated how these contextual factors influence outpatient OR processes and the quality of care delivered. The study setting was a German university-affiliated hospital performing approximately 6000 outpatient surgeries annually. During the 3-year-study period, the hospital significantly changed its outpatient OR facility layout from a decentralized (ie, ORs in adjacent areas of the building) to a centralized (ie, ORs in immediate vicinity of each other) design. To study the impact of the facility change on OR processes, we used a mixed methods approach, including process analysis, process modeling, and social network analysis of staff interactions. The change in facility layout was seen to influence OR processes in ways that could substantially affect patient outcomes. For example, we found a potential for more errors during handovers in the new centralized design due to greater interdependency between tasks and staff. Utilization of the mixed methods approach in our analysis, as compared with that of a single assessment method, enabled a deeper understanding of the OR work context and its influence on outpatient OR processes.

  10. Research and test facilities

    NASA Technical Reports Server (NTRS)

    1993-01-01

    A description is given of each of the following Langley research and test facilities: 0.3-Meter Transonic Cryogenic Tunnel, 7-by 10-Foot High Speed Tunnel, 8-Foot Transonic Pressure Tunnel, 13-Inch Magnetic Suspension & Balance System, 14-by 22-Foot Subsonic Tunnel, 16-Foot Transonic Tunnel, 16-by 24-Inch Water Tunnel, 20-Foot Vertical Spin Tunnel, 30-by 60-Foot Wind Tunnel, Advanced Civil Transport Simulator (ACTS), Advanced Technology Research Laboratory, Aerospace Controls Research Laboratory (ACRL), Aerothermal Loads Complex, Aircraft Landing Dynamics Facility (ALDF), Avionics Integration Research Laboratory, Basic Aerodynamics Research Tunnel (BART), Compact Range Test Facility, Differential Maneuvering Simulator (DMS), Enhanced/Synthetic Vision & Spatial Displays Laboratory, Experimental Test Range (ETR) Flight Research Facility, General Aviation Simulator (GAS), High Intensity Radiated Fields Facility, Human Engineering Methods Laboratory, Hypersonic Facilities Complex, Impact Dynamics Research Facility, Jet Noise Laboratory & Anechoic Jet Facility, Light Alloy Laboratory, Low Frequency Antenna Test Facility, Low Turbulence Pressure Tunnel, Mechanics of Metals Laboratory, National Transonic Facility (NTF), NDE Research Laboratory, Polymers & Composites Laboratory, Pyrotechnic Test Facility, Quiet Flow Facility, Robotics Facilities, Scientific Visualization System, Scramjet Test Complex, Space Materials Research Laboratory, Space Simulation & Environmental Test Complex, Structural Dynamics Research Laboratory, Structural Dynamics Test Beds, Structures & Materials Research Laboratory, Supersonic Low Disturbance Pilot Tunnel, Thermal Acoustic Fatigue Apparatus (TAFA), Transonic Dynamics Tunnel (TDT), Transport Systems Research Vehicle, Unitary Plan Wind Tunnel, and the Visual Motion Simulator (VMS).

  11. Control Room at the NACA’s Rocket Engine Test Facility

    NASA Image and Video Library

    1957-05-21

    Test engineers monitor an engine firing from the control room of the Rocket Engine Test Facility at the National Advisory Committee for Aeronautics (NACA) Lewis Flight Propulsion Laboratory. The Rocket Engine Test Facility, built in the early 1950s, had a rocket stand designed to evaluate high-energy propellants and rocket engine designs. The facility was used to study numerous different types of rocket engines including the Pratt and Whitney RL-10 engine for the Centaur rocket and Rocketdyne’s F-1 and J-2 engines for the Saturn rockets. The Rocket Engine Test Facility was built in a ravine at the far end of the laboratory because of its use of the dangerous propellants such as liquid hydrogen and liquid fluorine. The control room was located in a building 1,600 feet north of the test stand to protect the engineers running the tests. The main control and instrument consoles were centrally located in the control room and surrounded by boards controlling and monitoring the major valves, pumps, motors, and actuators. A camera system at the test stand allowed the operators to view the tests, but the researchers were reliant on data recording equipment, sensors, and other devices to provide test data. The facility’s control room was upgraded several times over the years. Programmable logic controllers replaced the electro-mechanical control devices. The new controllers were programed to operate the valves and actuators controlling the fuel, oxidant, and ignition sequence according to a predetermined time schedule.

  12. A novel sequential vegetable production facility for life support system in space

    NASA Astrophysics Data System (ADS)

    Liu, Hui; Berkovich, Yuliy A.; Liu, Hong; Fu, Yuming; Shao, Lingzhi; Erokhin, A. N.; Wang, Minjuan

    2012-07-01

    Vegetable cultivation plays a crucial role for dietary supplements and psychosocial benefits of the crew during manned space flight. The idea of onboard vegetables cultivation was generally proposed as the first step of food regeneration in life support system of space. Here a novel sequential vegetable production facility was developed, which was able to simulate microgravity conditions and carry out modularized-cultivation of leaf-vegetables. Its growth chamber (GC) had conic form and volume of 0.12 m ^{3}. Its planting surface of 0.154 m ^{2} was comprised of six ring-shaped root modules with a fibrous ion-exchange resin substrate. Root modules were fastened to a central porous tube supplying water, and moved on along with plant growth. The total illuminated crop area of 0.567 m ^{2} was provided by a combination of both red and white light emitting diodes distributed on the GC cone internal surface. In tests with a 24-hr photoperiod, the productivity of the facility at 0.3 kW for lettuce achieved 254.3 g eatable biomass per week. Compared to lettuce from market, the quality of lettuce of the facility did not change significantly during long-term cultivation. Our results demonstrate that the facility is high efficiency in vegetable production, and basically meets the application requirements of space microgravity environment. Keywords:, vegetable; modularized-cultivation; sequential production; life support system

  13. Toward eliminating blindness due to uncorrected refractive errors: assessment of refractive services in the northern and central regions of Ghana.

    PubMed

    Ntodie, Michael; Danquah, Lisa; Kandel, Himal; Abokyi, Samuel

    2014-11-01

    This study sought to document current refractive services in the northern and central regions of Ghana as a first step toward evidence-based planning of refractive services. A descriptive cross-sectional survey was carried out in health facilities in the northern and central regions of Ghana, which provided eye-care services. A semi-structured questionnaire was administered to gather information on each facility type, human resources providing refractive services, assessment of refraction and spectacle dispensing output and provider barriers to the services. Current outputs of refraction in the northern and central regions were 0.5 and 1.2 per cent of the estimated refractive needs, respectively. Spectacle dispensing services were below the outputs of refraction. Lack of equipment (36.8 per cent) and cost of providing spectacles frames (31.6 per cent), were identified as the main barriers to providing refractive services. The provision of refractive services in the study regions was inadequate. Lack of infrastructure and inadequate human resource were the major reasons for the limited service provision. This should be considered for planning refractive services in the study regions and Ghana as a whole. © 2014 The Authors. Clinical and Experimental Optometry © 2014 Optometrists Association Australia.

  14. 30 CFR 71.400 - Bathing facilities; change rooms; sanitary flush toilet facilities.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... WORK AREAS OF UNDERGROUND COAL MINES Surface Bathing Facilities, Change Rooms, and Sanitary Flush Toilet Facilities at Surface Coal Mines § 71.400 Bathing facilities; change rooms; sanitary flush toilet... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Bathing facilities; change rooms; sanitary...

  15. 30 CFR 71.400 - Bathing facilities; change rooms; sanitary flush toilet facilities.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... WORK AREAS OF UNDERGROUND COAL MINES Surface Bathing Facilities, Change Rooms, and Sanitary Flush Toilet Facilities at Surface Coal Mines § 71.400 Bathing facilities; change rooms; sanitary flush toilet... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Bathing facilities; change rooms; sanitary...

  16. 30 CFR 71.400 - Bathing facilities; change rooms; sanitary flush toilet facilities.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... WORK AREAS OF UNDERGROUND COAL MINES Surface Bathing Facilities, Change Rooms, and Sanitary Flush Toilet Facilities at Surface Coal Mines § 71.400 Bathing facilities; change rooms; sanitary flush toilet... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Bathing facilities; change rooms; sanitary...

  17. 30 CFR 71.400 - Bathing facilities; change rooms; sanitary flush toilet facilities.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... WORK AREAS OF UNDERGROUND COAL MINES Surface Bathing Facilities, Change Rooms, and Sanitary Flush Toilet Facilities at Surface Coal Mines § 71.400 Bathing facilities; change rooms; sanitary flush toilet... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Bathing facilities; change rooms; sanitary...

  18. Moderator Demonstration Facility Design and Optimization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McClanahan, Tucker C.; Gallmeier, Franz X.; Iverson, Erik B.

    2017-02-01

    The Spallation Neutron Source (SNS) facility at Oak Ridge National Laboratory (ORNL) is implementing a Moderator Demonstration Facility (MDF) to demonstrate the performance characteristics of advanced moderators central to the Second Target Station (STS) for SNS. The MDF will use the "spare" front-end installation within the SNS accelerator support complex – an ion source, radio-frequency quadrupole (RFQ) accelerator, and medium-energy beam transport (MEBT) chopper - to provide a 2.5 MeV proton beam of peak current 50 mA and maximum pulse length of less than 10 s at a repetition rate of no more than 60 Hz to a suitable neutron-producingmore » target to demonstrate those aspects of moderator performance necessary to meet the goals of the STS design e ort. The accelerator beam parameters are not open to variation beyond that described above - they are fixed by the nature of the spare front-end installation (the Integrated Test Stand Facility; ITSF). Accordingly, there are some neutronic challenges in developing prototypic moderator illumination from a very non-prototypic primary neutron source; the spallation source we are attempting to mimic has an extended neutron source volume approximately 40 cm long (in the direction of the proton beam), approximately 10 cm wide (horizontally transverse to the proton beam) and approximately 5 cm high (vertically transverse to the proton beam), and an isotropic evaporation energy spectrum with mean energy above 1 MeV. In contrast, the primary neutron source available from the 7Li(p,n) reaction (the most prolific at 2.5 MeV proton energy by more than an order of magnitude) is strongly anisotropic, with an energy spectrum that is both strongly dependent on emission angle and kinematically limited to less than 700 keV, and the interaction zone between the incident protons and any target material (neutron-producing or not) is intrinsically limited to a few tens of microns. The MDF will be unique and innovative amongst the world

  19. Atmospheric Radiation Measurement Program Climate Research Facility Operations Quarterly Report. October 1 - December 31, 2009.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    D. L. Sisterson

    2010-01-12

    related to individual instrument uptime. Thus, the average percentage of data in the Archive represents the average percentage of the time (24 hours per day, 92 days for this quarter) the instruments were operating this quarter. The Site Access Request System is a web-based database used to track visitors to the fixed and mobile sites, all of which have facilities that can be visited. The NSA locale has the Barrow and Atqasuk sites. The SGP locale has historically had a central facility, 23 extended facilities, 4 boundary facilities, and 3 intermediate facilities. Beginning this quarter, the SGP began a transition to a smaller footprint (150 km x 150 km) by rearranging the original and new instrumentation made available through the American Recovery and Reinvestment Act (ARRA). The central facility and 4 extended facilities will remain, but there will be up to 16 surface new characterization facilities, 4 radar facilities, and 3 profiler facilities sited in the smaller domain. This new configuration will provide observations at scales more appropriate to current and future climate models. The TWP locale has the Manus, Nauru, and Darwin sites. These sites will also have expanded measurement capabilities with the addition of new instrumentation made available through ARRA funds. It is anticipated that the new instrumentation at all the fixed sites will be in place within the next 12 months. The AMF continues its 20-month deployment in Graciosa Island, Azores, Portugal, that started May 1, 2009. The AMF will also have additional observational capabilities within the next 12 months. Users can participate in field experiments at the sites and mobile facility, or they can participate remotely. Therefore, a variety of mechanisms are provided to users to access site information. Users who have immediate (real-time) needs for data access can request a research account on the local site data systems. This access is particularly useful to users for quick decisions in executing time

  20. Segmental Versican Expression in the Trabecular Meshwork and Involvement in Outflow Facility

    PubMed Central

    Keller, Kate E.; Bradley, John M.; Vranka, Janice A.

    2011-01-01

    Purpose. Versican is a large proteoglycan with numerous chondroitin sulfate (CS) glycosaminoglycan (GAG) side chains attached. To assess versican's potential contributions to aqueous humor outflow resistance, its segmental distribution in the trabecular meshwork (TM) and the effect on outflow facility of silencing the versican gene were evaluated. Methods. Fluorescent quantum dots (Qdots) were perfused to label outflow pathways of anterior segments. Immunofluorescence with confocal microscopy and quantitative RT-PCR were used to determine versican protein and mRNA distribution relative to Qdot-labeled regions. Lentiviral delivery of shRNA-silencing cassettes to TM cells in perfused anterior segment cultures was used to evaluate the involvement of versican and CS GAG chains in outflow facility. Results. Qdot uptake by TM cells showed considerable segmental variability in both human and porcine outflow pathways. Regional levels of Qdot labeling were inversely related to versican protein and mRNA levels; versican levels were relatively high in sparsely Qdot-labeled regions and low in densely labeled regions. Versican silencing decreased outflow facility in human and increased facility in porcine anterior segments. However, RNAi silencing of ChGn, an enzyme unique to CS GAG biosynthesis, increased outflow facility in both species. The fibrillar pattern of versican immunostaining in the TM juxtacanalicular region was disrupted after versican silencing in perfusion culture. Conclusions. Versican appears to be a central component of the outflow resistance, where it may organize GAGs and other ECM components to facilitate and control open flow channels in the TM. However, the exact molecular organization of this resistance appears to differ between human and porcine eyes. PMID:21596823

  1. Monitored retrievable storage submission to Congress: Volume 2, Environmental assessment for a monitored retrievable storage facility. [Contains glossary

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    1986-02-01

    This Environmental Assessment (EA) supports the DOE proposal to Congress to construct and operate a facility for monitored retrievable storage (MRS) of spent fuel at a site on the Clinch River in the Roane County portion of Oak Ridge, Tennessee. The first part of this document is an assessment of the value of, need for, and feasibility of an MRS facility as an integral component of the waste management system. The second part is an assessment and comparison of the potential environmental impacts projected for each of six site-design combinations. The MRS facility would be centrally located with respect tomore » existing reactors, and would receive and canister spent fuel in preparation for shipment to and disposal in a geologic repository. 207 refs., 57 figs., 132 tabs.« less

  2. Indoor Athletic Facilities.

    ERIC Educational Resources Information Center

    Fleming, E. Scott

    2000-01-01

    Examines the concept of shared-use facilities to help financially support and meet the demand for athletic facilities. Shared-use considerations are explored including cost sharing of ongoing operations, aesthetics, locker rooms, support facilities, parking and site access, and building access and security. (GR)

  3. Aircraft Landing Dynamics Facility - A unique facility with new capabilities

    NASA Technical Reports Server (NTRS)

    Davis, P. A.; Stubbs, S. M.; Tanner, J. A.

    1985-01-01

    The Aircraft Landing Dynamics Facility (ALDF), formerly called the Landing Loads Track, is described. The paper gives a historical overview of the original NASA Langley Research Center Landing Loads Track and discusses the unique features of this national test facility. Comparisons are made between the original track characteristics and the new capabilities of the Aircraft Landing Dynamics Facility following the recently completed facility update. Details of the new propulsion and arresting gear systems are presented along with the novel features of the new high-speed carriage. The data acquisition system is described and the paper concludes with a review of future test programs.

  4. EPA Facility Registry Service (FRS): Facility Interests Dataset Download

    EPA Pesticide Factsheets

    This downloadable data package consists of location and facility identification information from EPA's Facility Registry Service (FRS) for all sites that are available in the FRS individual feature layers. The layers comprise the FRS major program databases, including:Assessment Cleanup and Redevelopment Exchange System (ACRES) : brownfields sites ; Air Facility System (AFS) : stationary sources of air pollution ; Air Quality System (AQS) : ambient air pollution data from monitoring stations; Bureau of Indian Affairs (BIA) : schools data on Indian land; Base Realignment and Closure (BRAC) facilities; Clean Air Markets Division Business System (CAMDBS) : market-based air pollution control programs; Comprehensive Environmental Response, Compensation, and Liability Information System (CERCLIS) : hazardous waste sites; Integrated Compliance Information System (ICIS) : integrated enforcement and compliance information; National Compliance Database (NCDB) : Federal Insecticide, Fungicide, and Rodenticide Act (FIFRA) and the Toxic Substances Control Act (TSCA); National Pollutant Discharge Elimination System (NPDES) module of ICIS : NPDES surface water permits; Radiation Information Database (RADINFO) : radiation and radioactivity facilities; RACT/BACT/LAER Clearinghouse (RBLC) : best available air pollution technology requirements; Resource Conservation and Recovery Act Information System (RCRAInfo) : tracks generators, transporters, treaters, storers, and disposers

  5. Design, analysis, and control of a large transport aircraft utilizing selective engine thrust as a backup system for the primary flight control. Ph.D. Thesis

    NASA Technical Reports Server (NTRS)

    Gerren, Donna S.

    1995-01-01

    A study has been conducted to determine the capability to control a very large transport airplane with engine thrust. This study consisted of the design of an 800-passenger airplane with a range of 5000 nautical miles design and evaluation of a flight control system, and design and piloted simulation evaluation of a thrust-only backup flight control system. Location of the four wing-mounted engines was varied to optimize the propulsive control capability, and the time constant of the engine response was studied. The goal was to provide level 1 flying qualities. The engine location and engine time constant did not have a large effect on the control capability. The airplane design did meet level 1 flying qualities based on frequencies, damping ratios, and time constants in the longitudinal and lateral-directional modes. Project pilots consistently rated the flying qualities as either level 1 or level 2 based on Cooper-Harper ratings. However, because of the limited control forces and moments, the airplane design fell short of meeting the time required to achieve a 30 deg bank and the time required to respond a control input.

  6. Health Facilities

    MedlinePlus

    Health facilities are places that provide health care. They include hospitals, clinics, outpatient care centers, and specialized care centers, ... psychiatric care centers. When you choose a health facility, you might want to consider How close it ...

  7. Aeronautical facilities assessment

    NASA Technical Reports Server (NTRS)

    Penaranda, F. E. (Compiler)

    1985-01-01

    A survey of the free world's aeronautical facilities was undertaken and an evaluation made on where the relative strengths and weaknesses exist. Special emphasis is given to NASA's own capabilities and needs. The types of facilities surveyed are: Wind Tunnels; Airbreathing Propulsion Facilities; and Flight Simulators

  8. Nurse-led HIV services and quality of care at health facilities in Kenya, 2014-2016.

    PubMed

    Rabkin, Miriam; Lamb, Matthew; Osakwe, Zainab T; Mwangi, Peter R; El-Sadr, Wafaa M; Michaels-Strasser, Susan

    2017-05-01

    To develop a novel measure to characterize human immunodeficiency virus (HIV) programme quality at health facilities in Kenya and explore its associations with patient- and facility-level characteristics. We developed a composite indicator to measure quality of HIV care, comprising: assessment of eligibility for antiretroviral therapy (ART); initiation of ART; and retention on ART or in care, if ineligible for ART, for 12 months. We applied the comprehensive retention indicator to routinely collected clinical data from 13 331 patients enrolled in HIV care and treatment at 63 health facilities in the Eastern and Nyanza regions of Kenya from 1 January 2014 to 31 March 2016. We explored the association between facility- and patient-level characteristics and the primary outcome: appropriate staging and management of HIV, and retention in care over 12 months. Of the enrolled patients, 8404 (63%) achieved comprehensive retention 12 months after enrolment in care. In univariate analyses, patients at facilities where nurses delivered HIV treatment services (including eligibility assessment, initiation and follow up of ART) had significantly higher comprehensive retention rates at 12 months. In multivariate analyses, after adjusting for both facility- and patient-level characteristics, patients at facilities where nurses initiated ART had significantly higher comprehensive retention in care at 12 months (relative risk, RR: 1.22; 95% confidence interval, CI: 1.00-1.48). Nurse-led HIV services were significantly associated with quality of care, confirming the central role of nurses in the achievement of global health goals, and the need for further investment in nursing education, training and mentoring.

  9. Administrators' perspectives on end-of-life care for cancer patients in Japanese long-term care facilities.

    PubMed

    Fukahori, Hiroki; Miyashita, Mitsunori; Morita, Tatsuya; Ichikawa, Takayuki; Akizuki, Nobuya; Akiyama, Miki; Shirahige, Yutaka; Eguchi, Kenji

    2009-10-01

    The purpose of this study was to clarify administrators' perspectives on availability of recommended strategies for end-of-life (EOL) care for cancer patients at long-term care (LTC) facilities in Japan. A cross-sectional survey was conducted with administrators at Japanese LTC facilities. Participants were surveyed about their facilities, reasons for hospitalization of cancer patients, and their perspectives on availability of and strategies for EOL care. The 97 responses were divided into medical facility (n = 24) and non-medical facility (n = 73) groups according to physician availability. The most frequent reasons for hospitalization were a sudden change in patient's condition (49.4%), lack of around-the-clock care (43.0%), and inability to palliate symptoms (41.0%). About 50% of administrators believed their facilities could provide EOL care if supported by palliative care experts. There was no significant difference between facility types (P = 0.635). Most administrators (81.2%) regarded unstable cancer patients as difficult to care for. However, many (68.4%) regarded opioids given orally as easy to administer, but regarded continuous subcutaneous infusion/central venous nutrition as difficult. Almost all administrators believed the most useful strategy was transferring patients to hospitals at the request of patients or family members (96.9%), followed by consultation with palliative care experts (88.5%). Although LTC facilities in Japan currently do not provide adequate EOL care for cancer patients, improvement might be possible with support by palliative care teams. Appropriate models are necessary for achieving a good death for cancer patients. Interventions based on these models are necessary for EOL care for cancer patients in LTC facilities.

  10. Patient Care Staffing Levels and Facility Characteristics in U.S. Hemodialysis Facilities

    PubMed Central

    Yoder, Laura A. G.; Xin, Wenjun; Norris, Keith C.; Yan, Guofen

    2013-01-01

    Background Higher numbers of registered nurses per patient have been associated with improved patient outcomes in acute care facilities. Variation and associations of patient-care staffing levels and hemodialysis facility characteristics have not been previously examined. Study Design Cross-sectional study using Poisson regression to examine associations betwee patient-care staffing levels and hemodialysis facility characteristics. Setting & Participants 4,800 U.S. hemodialysis facilities in the 2009 CMS ESRD Annual Facility Survey (CMS-2744), USRDS. Predictors Facility characteristics, including profit status, freestanding status, chain affiliatio and geographic region, adjusted for facility size, capacity, functional type, and urbanicity. Outcomes Patient care staffing levels, including ratios of Registered Nurses (RN), Licensed Practical Nurses (LPN), Patient Care Technicians (PCT), composite staff (RN+LPN+PCT), Social Workers, and Dietitians to in-center hemodialysis patients. Results After adjusting for background facility characteristics, the ratios of RNs and LPNs to patients were 35% (p<0.001) and 42% (p<0.001) lower, but the PCT-to-patient ratio was 16% (p<0.001) higher in for-profit facilities than those in nonprofit facilities (Rate ratio, 0.65, 95%CI, 0.63–0.68; 0.58, 0.51–0.65; 1.16, 1.12–1.19; respectively). Regionally, compared to the Northeast, the adjusted RN-to-patient ratio was 14% (p< 0.001) lower in the Midwest, 25% (p< 0.001) lower in the South, and 18% (p< 0.001) lower in the West. Even after additional adjustments, the large for-profit chains had significantly lower RN and LPN ratios than the largest nonprofit chain, but a significantly higher PCT-to-patient ratio. The overall composite staffing levels were also lower in for-profit and chain-affiliated facilities. The patterns hold when the hospital-based units were excluded. Limitations Nursing hours were not available. Conclusions The significant variation in patient-care staffing

  11. jsc2018e051938

    NASA Image and Video Library

    2018-05-31

    jsc2018e051938 - In the Integration Facility at the Baikonur Cosmodrome in Kazakhstan, the Expedition 56 prime and backup crewmembers pose for pictures May 31 with a soccer ball in front of the Soyuz booster rocket three of them will ride into space on June 6. The soccer ball and the booster bear the insignia of the FIFA World Cup soccer matches that will begin in mid-June throughout Russia. From left to right are the backup crewmembers, Anne McClain of NASA, Oleg Kononenko of Roscosmos and David Saint-Jacques of the Canadian Space Agency, and the prime crew, Serena Aunon-Chancellor of NASA, Sergey Prokopyev of Roscosmos and Alexander Gerst of the European Space Agency, who will launch June 6 in the Soyuz MS-09 spacecraft for a six-month mission on the International Space Station. ..Andrey Shelepin/Gagarin Cosmonaut Training Center.

  12. HIV treatment and care services for adolescents: a situational analysis of 218 facilities in 23 sub-Saharan African countries.

    PubMed

    Mark, Daniella; Armstrong, Alice; Andrade, Catarina; Penazzato, Martina; Hatane, Luann; Taing, Lina; Runciman, Toby; Ferguson, Jane

    2017-05-16

    In 2013, an estimated 2.1 million adolescents (age 10-19 years) were living with HIV globally. The extent to which health facilities provide appropriate treatment and care was unknown. To support understanding of service availability in 2014, Paediatric-Adolescent Treatment Africa (PATA), a non-governmental organisation (NGO) supporting a network of health facilities across sub-Saharan Africa, undertook a facility-level situational analysis of adolescent HIV treatment and care services in 23 countries. Two hundred and eighteen facilities, responsible for an estimated 80,072 HIV-infected adolescents in care, were surveyed. Sixty per cent of the sample were from PATA's network, with the remaining gathered via local NGO partners and snowball sampling. Data were analysed using descriptive statistics and coding to describe central tendencies and identify themes. Respondents represented three subregions: West and Central Africa ( n  = 59; 27%), East Africa ( n  = 77, 35%) and southern Africa ( n  = 82, 38%). Half (50%) of the facilities were in urban areas, 17% peri-urban and 33% rural settings. Insufficient data disaggregation and outcomes monitoring were critical issues. A quarter of facilities did not have a working definition of adolescence. Facilities reported non-adherence as their key challenge in adolescent service provision, but had insufficient protocols for determining and managing poor adherence and loss to follow-up. Adherence counselling focused on implications of non-adherence rather than its drivers. Facilities recommended peer support as an effective adherence and retention intervention, yet not all offered these services. Almost two-thirds reported attending to adolescents with adults and/or children, and half had no transitioning protocols. Of those with transitioning protocols, 21% moved pregnant adolescents into adult services earlier than their peers. There was limited sexual and reproductive health integration, with 63% of facilities

  13. KENNEDY SPACE CENTER, FLA. - Pamella J. Dana, Ph.D., director, Office of Tourism, Trade, and Economic Development in Florida, takes part in the proposal for locating NASA’s new Shared Services Center in the Central Florida Research Park, near Orlando. The presentation was given to NASA Administrator Sean O’Keefe and other officials. The center would centralize NASA’s payroll, accounting, human resources, facilities and procurement offices that are now handled at each field center. The consolidation is part of the One NASA focus. Six sites around the U.S. are under consideration by NASA.

    NASA Image and Video Library

    2004-02-19

    KENNEDY SPACE CENTER, FLA. - Pamella J. Dana, Ph.D., director, Office of Tourism, Trade, and Economic Development in Florida, takes part in the proposal for locating NASA’s new Shared Services Center in the Central Florida Research Park, near Orlando. The presentation was given to NASA Administrator Sean O’Keefe and other officials. The center would centralize NASA’s payroll, accounting, human resources, facilities and procurement offices that are now handled at each field center. The consolidation is part of the One NASA focus. Six sites around the U.S. are under consideration by NASA.

  14. Take a Tour of Our Facility | Energy Systems Integration Facility | NREL

    Science.gov Websites

    Take a Tour of Our Facility Take a Tour of Our Facility The Energy Systems Integration Facility Optical Characterization Laboratory System Performance Laboratory Power Systems Integration Laboratory Control Room Energy Storage Laboratory Outdoor Testing Areas Outdoor Testing Areas Energy Systems

  15. Use of personal digital assistants for data collection in a multi-site AIDS stigma study in rural south Nyanza, Kenya.

    PubMed

    Onono, M A; Carraher, N; Cohen, R C; Bukusi, E A; Turan, J M

    2011-09-01

    To describe the development, cost effectiveness and implementation of a PDA based electronic system to collect, verify and manage data from a multi-site study on HIV/AIDS stigma and pregnancy in a rural, resource-poor area. We worked within a large prevention of mother-to-child-transmission (PMTCT) program in nine rural health facilities to implement a PDA-based data collection system and to study the feasibility of its use in a multisite HIV research study in rural Kenya. The PDAs were programmed for collecting screening and eligibility data, and responses to structured interviews on HIV/AIDS stigma and violence in three local languages. Between November 2007 and December 2008, nine PDAs were used by Clinic and Community Health Assistants to enrol 1,270 participants on to the PMTCT program. Successes included: capacity-building of interviewers, low cost of implementation, quick turnaround time of data entry with good data quality, and convenience. Our study demonstrated the feasibility of utilizing PDAs for data collection in a multi-site observational study on HIV/AIDS stigma conducted in remote rural health facilities in Kenya. However, appropriate and frequent data backup protocols need to be established and paper forms are still needed as backup tools in resource-poor settings.

  16. Facilities | Argonne National Laboratory

    Science.gov Websites

    Skip to main content Argonne National Laboratory Toggle Navigation Toggle Search Research Facilities Advanced Powertrain Research Facility Center for Transportation Research Distributed Energy Research Center Engine Research Facility Heat Transfer Laboratory Materials Engineering Research Facility

  17. The cost of power outages in the business and public sectors in Israel: Revealed preference vs. subjective evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Beenstock, M.; Goldin, E.; Haitovsky, Y.

    1997-05-01

    The economic cost of power outages is a central parameter in the cost-benefit analysis of electric power reliability and the design of electric power systems. The authors present a new methodology for estimating the cost of power outages in the business and public sections and illustrate with data for Israel. The methodology is based on the principle of revealed preference, the cost of an outage may be inferred from the actions taken by consumers to mitigate losses induced by unsupplied electricity. If outages impose costs on businesses, managers are likely to invest in back-up power to mitigate the losses thatmore » are incurred when electricity is not supplied. Investment in back-up generators may then be used to impute the mitigated and unmitigated damage from outages. 12 refs., 3 figs., 7 tabs.« less

  18. U.S. Army Central and U.S. Army Contracting Command-Rock Island Need to Improve Facility Maintenance at King Abdullah II Special Operations Training Center

    DTIC Science & Technology

    2016-03-23

    cleaned so that they are free of dust, dirt, lint and human waste, and trash.” However, the contract did not explicitly state that the facilities...be free of mold/mildew. ACC–RI and ARCENT should review and modify the basic life support services contract, as necessary, to include measures...Responsibility, “The Sand Book,” July 18, 2014. 16 Unified Facility Criteria 1-202-01, “Host Nation Facilities in Support of Military Operations,” September 1

  19. EPA Facility Registry Service (FRS): Facility Interests Dataset - Intranet

    EPA Pesticide Factsheets

    This web feature service consists of location and facility identification information from EPA's Facility Registry Service (FRS) for all sites that are available in the FRS individual feature layers. The layers comprise the FRS major program databases, including:Assessment Cleanup and Redevelopment Exchange System (ACRES) : brownfields sites ; Air Facility System (AFS) : stationary sources of air pollution ; Air Quality System (AQS) : ambient air pollution data from monitoring stations; Bureau of Indian Affairs (BIA) : schools data on Indian land; Base Realignment and Closure (BRAC) facilities; Clean Air Markets Division Business System (CAMDBS) : market-based air pollution control programs; Comprehensive Environmental Response, Compensation, and Liability Information System (CERCLIS) : hazardous waste sites; Integrated Compliance Information System (ICIS) : integrated enforcement and compliance information; National Compliance Database (NCDB) : Federal Insecticide, Fungicide, and Rodenticide Act (FIFRA) and the Toxic Substances Control Act (TSCA); National Pollutant Discharge Elimination System (NPDES) module of ICIS : NPDES surface water permits; Radiation Information Database (RADINFO) : radiation and radioactivity facilities; RACT/BACT/LAER Clearinghouse (RBLC) : best available air pollution technology requirements; Resource Conservation and Recovery Act Information System (RCRAInfo) : tracks generators, transporters, treaters, storers, and disposers of haz

  20. Association of U.S. Dialysis Facility Neighborhood Characteristics with Facility-Level Kidney Transplantation

    PubMed Central

    Plantinga, Laura; Pastan, Stephen; Kramer, Michael; McClellan, Ann; Krisher, Jenna; Patzer, Rachel E.

    2014-01-01

    Background Improving access to optimal healthcare may depend on attributes of neighborhoods where patients receive healthcare services. We investigated whether characteristics of dialysis facility neighborhoods—where most patients with end-stage renal disease are treated—were associated with facility-level kidney transplantation. Methods We examined the association between census tract (neighborhood)-level sociodemographic factors and facility-level kidney transplantation rate in 3,983 U.S. dialysis facilities with reported kidney transplantation rates. Number of kidney transplants and total person-years contributed at the facility level in 2007-2010 were obtained from the Dialysis Facility Report and linked to census tract data on sociodemographic characteristics from the American Community Survey 2006-2010 by dialysis facility location. We used multivariable Poisson models with generalized estimating equations to estimate associations between neighborhood characteristics and transplant incidence. Results U.S. dialysis facilities were located in neighborhoods with substantially greater proportions of black and poor residents, relative to the national average. Most facility neighborhood characteristics were associated with transplant, with incidence rate ratios (95% CI) for standardized increments (in percentage) of neighborhood exposures of: living in poverty, 0.88 (0.84-0.92), black race, 0.83 (0.78-0.89); high school graduates, 1.22 (1.17-1.26); and unemployed, 0.90 (0.85-0.95). Conclusion Dialysis facility neighborhood characteristics may be modestly associated with facility rates of kidney transplantation. The success of dialysis facility interventions to improve access to kidney transplantation may partially depend on reducing neighborhood-level barriers. PMID:25196018

  1. Three-axis electron-beam test facility

    NASA Technical Reports Server (NTRS)

    Dayton, J. A., Jr.; Ebihara, B. T.

    1981-01-01

    An electron beam test facility, which consists of a precision multidimensional manipulator built into an ultra-high-vacuum bell jar, was designed, fabricated, and operated at Lewis Research Center. The position within the bell jar of a Faraday cup which samples current in the electron beam under test, is controlled by the manipulator. Three orthogonal axes of motion are controlled by stepping motors driven by digital indexers, and the positions are displayed on electronic totalizers. In the transverse directions, the limits of travel are approximately + or - 2.5 cm from the center with a precision of 2.54 micron (0.0001 in.); in the axial direction, approximately 15.0 cm of travel are permitted with an accuracy of 12.7 micron (0.0005 in.). In addition, two manually operated motions are provided, the pitch and yaw of the Faraday cup with respect to the electron beam can be adjusted to within a few degrees. The current is sensed by pulse transformers and the data are processed by a dual channel box car averager with a digital output. The beam tester can be operated manually or it can be programmed for automated operation. In the automated mode, the beam tester is controlled by a microcomputer (installed at the test site) which communicates with a minicomputer at the central computing facility. The data are recorded and later processed by computer to obtain the desired graphical presentations.

  2. NOx emissions from a Central California dairy

    NASA Astrophysics Data System (ADS)

    Hasson, Alam S.; Ogunjemiyo, Segun O.; Trabue, Steven; Ashkan, Shawn; Scoggin, Kenwood; Steele, Julie; Olea, Catalina; Middala, Srikar; Vu, Kennedy; Scruggs, Austen; Addala, Laxmi R.; Nana, Lucien

    2013-05-01

    Concentrations of NOx (NO + NO2) were monitored downwind from a Central California dairy facility during 2011 and 2012. NOx concentrations at the dairy were significantly higher than the background levels during August 2011 primarily due to the presence of elevated NO, but were indistinguishable from background concentrations during January and April 2012. A Gaussian plume model (AERMOD) and a Lagrangian back trajectory model (Wind Trax) were used to estimate the flux of NO from the dairy during August 2011 with the assumption that emissions were primarily from animal feed. NO emissions from silage were also directly measured from feed to provide additional insight into the sources. Isolation flux chamber measurements imply an NO flux from the feed of about 1.3 × 10-3 g m-2 h-1, but these relatively low fluxes are inconsistent with the elevated NO concentrations observed during August 2011. This implies that either the flux chamber method grossly underestimates the true NO emissions from feed, or that most of the ambient NO measured at the dairy is from other sources. Emissions from farm machinery may account for the NO concentrations observed. Animal feed thus appears to be a small contributor to NOx emissions within Central California.

  3. Facilities Performance Indicators Report 2011-12: Tracking Your Facilities Vital Signs

    ERIC Educational Resources Information Center

    APPA: Association of Higher Education Facilities Officers, 2013

    2013-01-01

    This paper provides an expanded Web-based "Facilities Performance Indicators (FPI) Report." The purpose of APPA's Facilities Performance Indicators is to provide a representative set of statistics about facilities in educational institutions. APPA's Information and Research Committee's goal for this year was to enhance the…

  4. Opportunities for Energy Efficiency and Open Automated Demand Response in Wastewater Treatment Facilities in California -- Phase I Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lekov, Alex; Thompson, Lisa; McKane, Aimee

    This report summarizes the Lawrence Berkeley National Laboratory?s research to date in characterizing energy efficiency and automated demand response opportunities for wastewater treatment facilities in California. The report describes the characteristics of wastewater treatment facilities, the nature of the wastewater stream, energy use and demand, as well as details of the wastewater treatment process. It also discusses control systems and energy efficiency and automated demand response opportunities. In addition, several energy efficiency and load management case studies are provided for wastewater treatment facilities.This study shows that wastewater treatment facilities can be excellent candidates for open automated demand response and thatmore » facilities which have implemented energy efficiency measures and have centralized control systems are well-suited to shift or shed electrical loads in response to financial incentives, utility bill savings, and/or opportunities to enhance reliability of service. Control technologies installed for energy efficiency and load management purposes can often be adapted for automated demand response at little additional cost. These improved controls may prepare facilities to be more receptive to open automated demand response due to both increased confidence in the opportunities for controlling energy cost/use and access to the real-time data.« less

  5. Payment methods for outpatient care facilities.

    PubMed

    Yuan, Beibei; He, Li; Meng, Qingyue; Jia, Liying

    2017-03-03

    Outpatient care facilities provide a variety of basic healthcare services to individuals who do not require hospitalisation or institutionalisation, and are usually the patient's first contact. The provision of outpatient care contributes to immediate and large gains in health status, and a large portion of total health expenditure goes to outpatient healthcare services. Payment method is one of the most important incentive methods applied by purchasers to guide the performance of outpatient care providers. To assess the impact of different payment methods on the performance of outpatient care facilities and to analyse the differences in impact of payment methods in different settings. We searched the Cochrane Central Register of Controlled Trials (CENTRAL), 2016, Issue 3, part of the Cochrane Library (searched 8 March 2016); MEDLINE, OvidSP (searched 8 March 2016); Embase, OvidSP (searched 24 April 2014); PubMed (NCBI) (searched 8 March 2016); Dissertations and Theses Database, ProQuest (searched 8 March 2016); Conference Proceedings Citation Index (ISI Web of Science) (searched 8 March 2016); IDEAS (searched 8 March 2016); EconLit, ProQuest (searched 8 March 2016); POPLINE, K4Health (searched 8 March 2016); China National Knowledge Infrastructure (searched 8 March 2016); Chinese Medicine Premier (searched 8 March 2016); OpenGrey (searched 8 March 2016); ClinicalTrials.gov, US National Institutes of Health (NIH) (searched 8 March 2016); World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) (searched 8 March 2016); and the website of the World Bank (searched 8 March 2016).In addition, we searched the reference lists of included studies and carried out a citation search for the included studies via ISI Web of Science to find other potentially relevant studies. We also contacted authors of the main included studies regarding any further published or unpublished work. Randomised trials, non-randomised trials, controlled before

  6. Promoting hand hygiene and prudent use of antimicrobials in long-term care facilities.

    PubMed

    Rummukainen, Maija; Jakobsson, Aino; Karppi, Pertti; Kautiainen, Hannu; Lyytikäinen, Outi

    2009-03-01

    A multidisciplinary team visited all long-term care facilities (n = 123) for elderly persons in the Central Finland health care district (population, 265,000) during 2004-2005. Use of alcohol-based hand rubs and ongoing systematic antimicrobials were assessed. Thereafter, regional guidelines for prudent use of antimicrobials were published. One year after the visits, a significant increase in the mean amount of alcohol-based hand rubs used was detected while usage of antimicrobials for the prevention of urinary tract reinfections had decreased.

  7. Centrifuge Facility Conceptual System Study. Volume 1: Facility overview and habitats

    NASA Technical Reports Server (NTRS)

    Synnestvedt, Robert (Editor)

    1990-01-01

    The results are presented for a NASA Phase 1 study conducted from mid 1987 through mid 1989 at Ames Research Center. The Centrifuge Facility is the major element of the biological research facility for the implementation of NASA's Life Science Research Program on Space Station Freedom using non-human specimens (such as small primates, rodents, plants, insects, cell tissues). Five systems are described which comprise the Facility: habitats, holding units, centrifuge, glovebox, and service unit. Volume 1 presents a facility overview and describes the habitats - modular units which house living specimens.

  8. 47 CFR 4.5 - Definitions of outage, special offices and facilities, and 911 special facilities.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... facilities, and 911 special facilities. 4.5 Section 4.5 Telecommunication FEDERAL COMMUNICATIONS COMMISSION... Definitions of outage, special offices and facilities, and 911 special facilities. (a) Outage is defined as a... government facilities.” 911 special facilities are addressed separately in paragraph (e) of this section. (c...

  9. Environmental Assessment for Central Campus Complex John F. Kennedy Space Center, Florida

    NASA Technical Reports Server (NTRS)

    Dankert, Donald

    2013-01-01

    This Environmental Assessment addresses the Proposed Action to consolidate multiple facilities in the Kennedy Space Center (KSC) Industrial Area by constructing two new buildings in the existing headquarters area between NASA Parkway, 3rd Street, C Avenue, and D Avenue. Under the Proposed Action, the historic Headquarters Building will be demolished and a new building will be constructed closer to the Operations and Checkout Building by centering it on D A venue (Hunton Brady Architects, P A and Jones Edmunds and Associates, Inc. 2011). This option was selected from a group of 15 initial sketches as the most viable option during a Central Campus Complex Siting Study completed in February 2011. A No-Action Alternative is also presented in which no demolition or construction of new facilities would occur. Implementing the Proposed Action will have major impacts to cultural resources, while the remaining environmental impacts will be minor.

  10. Additional spectra of asteroid 1996 FG3, backup target of the ESA MarcoPolo-R mission

    NASA Astrophysics Data System (ADS)

    de León, J.; Lorenzi, V.; Alí-Lagoa, V.; Licandro, J.; Pinilla-Alonso, N.; Campins, H.

    2013-08-01

    Context. Near-Earth binary asteroid (175706) 1996 FG3 is the current backup target of the ESA MarcoPolo-R mission, selected for the study phase of ESA M3 missions. It is a primitive (C-type) asteroid that shows significant variation in its visible and near-infrared spectra. Aims: Here we present new visible and near-infrared spectra of 1996 FG3. We compare our new data with other published spectra, analysing the variation in the spectral slope. The asteroid will not be observable again over the next three years at least. Methods: We obtained visible and near-infrared spectra using DOLORES and NICS instruments, respectively, at the Telescopio Nazionale Galileo (TNG), a 3.6 m telescope located at El Roque de los Muchachos Observatory in La Palma, Spain. To compare with other published spectra of the asteroid, we computed the spectral slope S', and studied any plausible correlation of this quantity with the phase angle (α). Results: In the case of visible spectra, we find a variation in spectral slope of ΔS' = 0.15 ± 0.10%/103 Å/° for 3°<α< 18°, which is in good agreement with the values found in the literature for the phase reddening effect. In the case of the near-infrared, there seems to be a trend between the reddening of the spectra and the phase angle, excluding one point. We find a variation in the slope of ΔS' = 0.04 ± 0.08%/103 Å/° for 6° < α < 51°. Our computed variation in S' is in good agreement with the only two values found in the literature for the phase reddening in the near-infrared. Conclusions: The variation in the spectral slope of asteroid 1996 FG3 shows a trend with the phase angle at the time of the observations, both in the visible and the near-infrared. It is worth noting that, to fully explain this spectral variability we should take into account other factors, like the position of the secondary component of the binary asteroid 1999 FG3 with respect to the primary, or the spin axis orientation at the time of the observations

  11. Energy Systems Integration Facility (ESIF) Facility Stewardship Plan: Revision 2.1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Torres, Juan; Anderson, Art

    The U.S. Department of Energy (DOE), Office of Energy Efficiency and Renewable Energy (EERE), has established the Energy Systems Integration Facility (ESIF) on the campus of the National Renewable Energy Laboratory (NREL) and has designated it as a DOE user facility. This 182,500-ft2 research facility provides state-of-the-art laboratory and support infrastructure to optimize the design and performance of electrical, thermal, fuel, and information technologies and systems at scale. This Facility Stewardship Plan provides DOE and other decision makers with information about the existing and expected capabilities of the ESIF and the expected performance metrics to be applied to ESIF operations.more » This plan is a living document that will be updated and refined throughout the lifetime of the facility.« less

  12. Hazardous Materials Verification and Limited Characterization Report on Sodium and Caustic Residuals in Materials and Fuel Complex Facilities MFC-799/799A

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gary Mecham

    2010-08-01

    This report is a companion to the Facilities Condition and Hazard Assessment for Materials and Fuel Complex Sodium Processing Facilities MFC-799/799A and Nuclear Calibration Laboratory MFC-770C (referred to as the Facilities Condition and Hazards Assessment). This report specifically responds to the requirement of Section 9.2, Item 6, of the Facilities Condition and Hazards Assessment to provide an updated assessment and verification of the residual hazardous materials remaining in the Sodium Processing Facilities processing system. The hazardous materials of concern are sodium and sodium hydroxide (caustic). The information supplied in this report supports the end-point objectives identified in the Transition Planmore » for Multiple Facilities at the Materials and Fuels Complex, Advanced Test Reactor, Central Facilities Area, and Power Burst Facility, as well as the deactivation and decommissioning critical decision milestone 1, as specified in U.S. Department of Energy Guide 413.3-8, “Environmental Management Cleanup Projects.” Using a tailored approach and based on information obtained through a combination of process knowledge, emergency management hazardous assessment documentation, and visual inspection, this report provides sufficient detail regarding the quantity of hazardous materials for the purposes of facility transfer; it also provides that further characterization/verification of these materials is unnecessary.« less

  13. Dust exposure in workers from grain storage facilities in Costa Rica.

    PubMed

    Rodríguez-Zamora, María G; Medina-Escobar, Lourdes; Mora, Glend; Zock, Jan-Paul; van Wendel de Joode, Berna; Mora, Ana M

    2017-08-01

    About 12 million workers are involved in the production of basic grains in Central America. However, few studies in the region have examined the occupational factors associated with inhalable dust exposure. (i) To assess the exposure to inhalable dust in workers from rice, maize, and wheat storage facilities in Costa Rica; (ii) to examine the occupational factors associated with this exposure; and (iii) to measure concentrations of respirable and thoracic particles in different areas of the storage facilities. We measured inhalable (<100μm) dust concentrations in 176 personal samples collected from 136 workers of eight grain storage facilities in Costa Rica. We also measured respirable (<4μm) and thoracic (<10μm) dust particles in several areas of the storage facilities. Geometric mean (GM) and geometric standard deviation (GSD) inhalable dust concentrations were 2.0mg/m 3 and 7.8 (range=<0.2-275.4mg/m 3 ). Personal inhalable dust concentrations were associated with job category [GM for category/GM for administrative staff and other workers (95% CI)=4.4 (2.6, 7.2) for packing; 20.4 (12.3, 34.7) for dehulling; 109.6 (50.1, 234.4) for unloading in flat bed sheds; 24.0 (14.5, 39.8) for unloading in pits; and 31.6 (18.6, 52.5) for drying], and cleaning task [15.8 (95% CI: 10.0, 26.3) in workers who cleaned in addition to their regular tasks]. Higher area concentrations of thoracic dust particles were found in wheat (GM and GSD=4.3mg/m 3 and 4.5) and maize (3.0mg/m 3 and 3.9) storage facilities, and in grain drying (2.3mg/m 3 and 3.1) and unloading (1.5mg/m 3 and 4.8) areas. Operators of grain storage facilities showed elevated inhalable dust concentrations, mostly above international exposure limits. Better engineering and administrative controls are needed. Copyright © 2017 Elsevier GmbH. All rights reserved.

  14. Feasibility study: Liquid hydrogen plant, 30 tons per day

    NASA Technical Reports Server (NTRS)

    1975-01-01

    The design considerations of the plant are discussed in detail along with management planning, objective schedules, and cost estimates. The processing scheme is aimed at ultimate use of coal as the basic raw material. For back-up, and to provide assurance of a dependable and steady supply of hydrogen, a parallel and redundant facility for gasifying heavy residual oil will be installed. Both the coal and residual oil gasifiers will use the partial oxidation process.

  15. STS-71 astronauts training in Russia

    NASA Image and Video Library

    1994-09-20

    Astronaut Norman E. Thagard in a cosmonaut space suit in the Training Simulator Facility at the Gagarin Cosmonaut Training Center (Star City), near Moscow, Russia. In March 1995, astronaut Thagard is scheduled to be launched in a Russian Soyuz spacecraft with two cosmonauts to begin a three-month tour of duty on the Russian Mir Space Station. Thagard, along with his back-up, astronaut Bonnie J. Dunbar, has been training in Russian since February 1994.

  16. Environmental Assessment of Installation Development at McGuire Air Force Base, New Jersey

    DTIC Science & Technology

    2008-02-01

    months. The primary fuel used by the boilers is natural gas , but they are also capable of using oil as a backup. Excess heating is capacity available... oil ft 2 square feet FUB Facilities Utilization Board FY fiscal year GIS Geographical Information System GOV government-owned vehicle GRDC...under the command and control of AMC, approximately 18 miles southeast of downtown Trenton, New Jersey. It is bounded by the U.S. Army’s Fort Dix

  17. Payment methods for outpatient care facilities

    PubMed Central

    Yuan, Beibei; He, Li; Meng, Qingyue; Jia, Liying

    2017-01-01

    Background Outpatient care facilities provide a variety of basic healthcare services to individuals who do not require hospitalisation or institutionalisation, and are usually the patient's first contact. The provision of outpatient care contributes to immediate and large gains in health status, and a large portion of total health expenditure goes to outpatient healthcare services. Payment method is one of the most important incentive methods applied by purchasers to guide the performance of outpatient care providers. Objectives To assess the impact of different payment methods on the performance of outpatient care facilities and to analyse the differences in impact of payment methods in different settings. Search methods We searched the Cochrane Central Register of Controlled Trials (CENTRAL), 2016, Issue 3, part of the Cochrane Library (searched 8 March 2016); MEDLINE, OvidSP (searched 8 March 2016); Embase, OvidSP (searched 24 April 2014); PubMed (NCBI) (searched 8 March 2016); Dissertations and Theses Database, ProQuest (searched 8 March 2016); Conference Proceedings Citation Index (ISI Web of Science) (searched 8 March 2016); IDEAS (searched 8 March 2016); EconLit, ProQuest (searched 8 March 2016); POPLINE, K4Health (searched 8 March 2016); China National Knowledge Infrastructure (searched 8 March 2016); Chinese Medicine Premier (searched 8 March 2016); OpenGrey (searched 8 March 2016); ClinicalTrials.gov, US National Institutes of Health (NIH) (searched 8 March 2016); World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) (searched 8 March 2016); and the website of the World Bank (searched 8 March 2016). In addition, we searched the reference lists of included studies and carried out a citation search for the included studies via ISI Web of Science to find other potentially relevant studies. We also contacted authors of the main included studies regarding any further published or unpublished work. Selection criteria Randomised

  18. EPA Facility Registry Service (FRS): Facility Interests Dataset - Intranet Download

    EPA Pesticide Factsheets

    This downloadable data package consists of location and facility identification information from EPA's Facility Registry Service (FRS) for all sites that are available in the FRS individual feature layers. The layers comprise the FRS major program databases, including:Assessment Cleanup and Redevelopment Exchange System (ACRES) : brownfields sites ; Air Facility System (AFS) : stationary sources of air pollution ; Air Quality System (AQS) : ambient air pollution data from monitoring stations; Bureau of Indian Affairs (BIA) : schools data on Indian land; Base Realignment and Closure (BRAC) facilities; Clean Air Markets Division Business System (CAMDBS) : market-based air pollution control programs; Comprehensive Environmental Response, Compensation, and Liability Information System (CERCLIS) : hazardous waste sites; Integrated Compliance Information System (ICIS) : integrated enforcement and compliance information; National Compliance Database (NCDB) : Federal Insecticide, Fungicide, and Rodenticide Act (FIFRA) and the Toxic Substances Control Act (TSCA); National Pollutant Discharge Elimination System (NPDES) module of ICIS : NPDES surface water permits; Radiation Information Database (RADINFO) : radiation and radioactivity facilities; RACT/BACT/LAER Clearinghouse (RBLC) : best available air pollution technology requirements; Resource Conservation and Recovery Act Information System (RCRAInfo) : tracks generators, transporters, treaters, storers, and disposers

  19. The Automation of the Transonic Experimental Facility (TEF) and the Aerodynamic Experimental Facility (AEF)

    DTIC Science & Technology

    2015-10-01

    ARL-TR-7506 ● OCT 2015 US Army Research Laboratory The Automation of the Transonic Experimental Facility (TEF) and the...Laboratory The Automation of the Transonic Experimental Facility (TEF) and the Aerodynamic Experimental Facility (AEF) by Charith R Ranawake Weapons...To) 05/2015–08/2015 4. TITLE AND SUBTITLE The Automation of the Transonic Experimental Facility (TEF) and the Aerodynamic Experimental Facility

  20. Automatic Estimation of the Radiological Inventory for the Dismantling of Nuclear Facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Garcia-Bermejo, R.; Felipe, A.; Gutierrez, S.

    The estimation of the radiological inventory of Nuclear Facilities to be dismantled is a process that included information related with the physical inventory of all the plant and radiological survey. Estimation of the radiological inventory for all the components and civil structure of the plant could be obtained with mathematical models with statistical approach. A computer application has been developed in order to obtain the radiological inventory in an automatic way. Results: A computer application that is able to estimate the radiological inventory from the radiological measurements or the characterization program has been developed. In this computer applications has beenmore » included the statistical functions needed for the estimation of the central tendency and variability, e.g. mean, median, variance, confidence intervals, variance coefficients, etc. This computer application is a necessary tool in order to be able to estimate the radiological inventory of a nuclear facility and it is a powerful tool for decision taken in future sampling surveys.« less