ERIC Educational Resources Information Center
Anderson, Calvin E.
Presented are materials prepared for the inservice education of school maintenance personnel on the subject of energy conservation in school facilities operations. The course is designed to help maintenance staff understand their schools' energy usage and formulate plans to control that usage. Among the topics covered are building inventory,…
High-Performance Computing Data Center Power Usage Effectiveness |
Power Usage Effectiveness When the Energy Systems Integration Facility (ESIF) was conceived, NREL set an , ventilation, and air conditioning (HVAC), which captures fan walls, fan coils that support the data center
Energy Efficiency Through Lighting Upgrades
DOE Office of Scientific and Technical Information (OSTI.GOV)
Berst, Kara; Howeth, Maria
2013-02-26
Lighting upgrades including neon to LED, incandescent to CFL's and T-12 to T-8 and T-5's were completed through this grant. A total of 16 Chickasaw nation facilities decreased their carbon footprint because of these grant funds. Calculations used were based on comparing the energy usage from the previous year's average and the current energy usage. For facilities without a full year's set of energy bills, the month after installation was compared to the same month from the previous year. Overall, the effect the lighting change-outs had for the gaming centers and casinos far exceeded expectations. For the Madill Gaming Center;more » both an interior and exterior upgrade was performed which resulted in a 31% decrease in energy consumption. This same reduction was seen in every facility that participated in the grant. Just by simply changing out light bulbs to newer energy efficient equivalents, a decrease in energy usage can be achieved and this was validated by the return on investment seen at Chickasaw Nation facilities. Along with the technical project tasks were awareness sessions presented at Chickasaw Head Starts. The positive message of environmental stewardship was passed down to head start students and passed along to Chickasaw employees. Excitement was created in those that learned what they could do to help reduce their energy bills and many followed through and took the idea home. For a fairy low cost, the general public can also use this technique to lower their energy consumption both at home and at work. Although the idea behind the project was somewhat simple, true benefits have been gained through environmental awareness and reductions of energy costs.« less
Saving Energy. Managing School Facilities, Guide 3.
ERIC Educational Resources Information Center
Department for Education and Employment, London (England). Architects and Building Branch.
This guide offers information on how schools can implement an energy saving action plan to reduce their energy costs. Various low-cost energy-saving measures are recommended covering heating levels and heating systems, electricity demand reduction and lighting, ventilation, hot water usage, and swimming pool energy management. Additional…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kora, Angela R.; Brown, Daryl R.; Dixon, Douglas R.
2010-03-09
This report documents an assessment was performed by a team of engineers from Pacific Northwest National Laboratory (PNNL) under contract to the Installation Management Command (IMCOM) Pacific Region Office (PARO). The effort used the Facility Energy Decision System (FEDS) model to determine how energy is consumed at five U.S. Army Garrison-Japan (USAG-J) installations in the Honshu area, identify the most cost-effective energy retrofit measures, and calculate the potential energy and cost savings.
Design and operation considerations for attic inlets
USDA-ARS?s Scientific Manuscript database
Improving energy efficiency and environmental control in poultry facilities is essential for profitability. Increases in energy costs have prompted evaluation of solar energy systems and passive solar systems such as attic inlets have been adopted as a means to reduce fuel usage. Successful implem...
A Study of Airbase Facility/Utility Energy R and D Requirements
1992-04-01
facility/utility energy requirements for system implementations, modifications, or deletions were collected, entered into the database, and compared with...BASE_________ ENERGY LOS1 %) 200 MBtu TOTAL COSTS 100 Motu ELECTRIC 100 Motu THERMAL337 Motu ,, OF1FUEL 100 MBtu OF(10 11 PURCHASED S 1800.00 ELECTRIC...this page. Usage Data = *.BTU I. Correct spelling of Base name and Command 2. Macro does the following: Inserts or deletes columns or rows so that D4
Prediction and characterization of application power use in a high-performance computing environment
Bugbee, Bruce; Phillips, Caleb; Egan, Hilary; ...
2017-02-27
Power use in data centers and high-performance computing (HPC) facilities has grown in tandem with increases in the size and number of these facilities. Substantial innovation is needed to enable meaningful reduction in energy footprints in leadership-class HPC systems. In this paper, we focus on characterizing and investigating application-level power usage. We demonstrate potential methods for predicting power usage based on a priori and in situ characteristics. Lastly, we highlight a potential use case of this method through a simulated power-aware scheduler using historical jobs from a real scientific HPC system.
One of the major contributions of Greenhouse Gas (GHG) emissions from water resource recovery facilities results from the energy used by the pumping regime of the lift stations. This project demonstrated an energy-efficient control method of lift station system operation that uti...
ERIC Educational Resources Information Center
Gutmanis, Ivars; And Others
The report presents the methodology used by the National Planning Association (NPA), under contract to the Federal Energy Administration (FEA), to estimate direct labor usage coefficients in some sixty different occupational categories involved in construction, operation, and maintenance of energy facilities. Volume 1 presents direct labor usage…
DOT National Transportation Integrated Search
2014-01-01
Reducing the environmental impact of facilities and operations has become an important function for many organizations. In many : cases, such as utility and fuel use, reducing these impacts can also be coupled to financial savings. The Kansas Departm...
Energy and environmental evaluation of combined cooling heating and power system
NASA Astrophysics Data System (ADS)
Bugaj, Andrzej
2017-11-01
The paper addresses issues involving problems of implementing combined cooling, heating and power (CCHP) system to industrial facility with well-defined demand profiles of cooling, heating and electricity. The application of CCHP system in this particular industrial facility is being evaluated by comparison with the reference system that consists of three conventional methods of energy supply: (a) electricity from external grid, (b) heat from gas-fired boilers and (c) cooling from vapour compression chillers run by electricity from the grid. The CCHP system scenario is based on the combined heat and power (CHP) plant with gas turbine-compressor arrangement and water/lithium bromide absorption chiller of a single-effect type. Those two scenarios are analysed in terms of annual primary energy usage as well as emissions of CO2. The results of the analysis show an extent of primary energy savings of the CCHP system in comparison with the reference system. Furthermore, the environmental impact of the CCHP usage, in the form of greenhouse gases emission reductions, compares quite favourably with the reference conventional option.
Improved Planning and Programming for Energy Efficient New Army Facilities
1988-10-01
setpoints to occupant comfort must be considered carefully. Cutting off the HVAC system to the bedrooms during the day produced only small savings...functions of a building and minimizing the energy usage through optimization . It includes thermostats, time switches, programmable con- trollers...microprocessor systems, computers, and sensing devices that are linked with control and power components to manage energy use. This system optimizes load
ERIC Educational Resources Information Center
Davenport, Mona Yvette
2010-01-01
This study tested the perceptions of involvement components (Non-Academic Facility Usage, Intra-Racial Relations, Campus and Charleston Involvement, Faculty Interaction, Academic Facility Usage, Inter-Racial Relations, Cultural Center Usage, and Athletic Facilities Usage) for first generation and non-first generation African American and Hispanic…
DOT National Transportation Integrated Search
2014-01-01
Reducing the environmental impact of facilities and operations has become an important function for many organizations. In many cases, such as utility and fuel use, reducing these impacts can also be coupled to financial savings. The Kansas Departmen...
Today's Leaders for a Sustainable Tomorrow
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wood, Bryan
2013-02-27
Today's Leaders for a Sustainable Tomorrow is a collaboration of five residential environmental learning centers (Audubon Center of the North Woods, Deep Portage Learning Center, Laurentian Environmental Center, Long Lake Conservation Center and Wolf Ridge Environmental Learning Center) that together increased energy efficiency, energy conservation and renewable energy technologies through a number of different means appropriate for each unique center. For energy efficiency upgrades the centers installed envelope improvements to seal air barriers through better insulation in walls, ceilings, windows, doors as well as the installation of more energy efficient windows, doors, lighting and air ventilation systems. Through energy sub-metermore » monitoring the centers are able to accurately chart the usage of energy at each of their campuses and eliminate unnecessary energy usage. Facilities reduced their dependence on fossil fuel energy sources through the installation of renewable energy technologies including wood gasification, solar domestic hot water, solar photovoltaic, solar air heat, geothermal heating and wind power. Centers also installed energy education displays on the specific renewable energy technologies used at the center.« less
A comparative study of fluorescent and LED lighting in industrial facilities
NASA Astrophysics Data System (ADS)
Perdahci PhD, C.; Akin BSc, H. C.; Cekic Msc, O.
2018-05-01
Industrial facilities have always been in search for reducing outgoings and minimizing energy consumption. Rapid developments in lighting technology require more energy efficient solutions not only for industries but also for many sectors and for households. Addition of solid-state technology has brought LED lamps into play and with LED lamp usage, efficacy level has reached its current values. Lighting systems which uses fluorescent and LED lamps have become the prior choice for many industrial facilities. This paper presents a comparative study about fluorescent and LED based indoor lighting systems for a warehouse building in an industrial facility in terms of lighting distribution values, colour rendering, power consumption, energy efficiency and visual comfort. Both scenarios have been modelled and simulated by using Relux and photometric data for the luminaires have been gathered by conducting tests and measurements in an accredited laboratory.
Patterns and determinants of communal latrine usage in urban poverty pockets in Bhopal, India.
Biran, A; Jenkins, M W; Dabrase, P; Bhagwat, I
2011-07-01
To explore and explain patterns of use of communal latrine facilities in urban poverty pockets. Six poverty pockets with communal latrine facilities representing two management models (Sulabh and municipal) were selected. Sampling was random and stratified by poverty pocket population size. A seventh, community-managed facility was also included. Data were collected by exit interviews with facility users and by interviews with residents from a randomly selected representative sample of poverty pocket households, on social, economic and demographic characteristics of households, latrine ownership, defecation practices, costs of using the facility and distance from the house to the facility. A tally of facility users was kept for 1 day at each facility. Data were analysed using logistic regression modelling to identify determinants of communal latrine usage. Communal latrines differed in their facilities, conditions, management and operating characteristics, and rates of usage. Reported usage rates among non-latrine-owning households ranged from 15% to 100%. There was significant variation in wealth, occupation and household structure across the poverty pockets as well as in household latrine ownership. Households in pockets with municipal communal latrine facilities appeared poorer. Households in pockets with Sulabh-managed communal facilities were significantly more likely to own a household latrine. Determinants of communal facility usage among households without a latrine were access and convenience (distance and opening hours), facility age, cleanliness/upkeep and cost. The ratio of male to female users was 2:1 across all facilities for both adults and children. Provision of communal facilities reduces but does not end the problem of open defecation in poverty pockets. Women appear to be relatively poorly served by communal facilities and, cost is a barrier to use by poorer households. Results suggest improving facility convenience and access and modifying fee structures could lead to increased rates of usage. Attention to possible barriers to usage at household level associated particularly with having school-age children and with pre-school childcare needs may also be warranted. © 2011 Blackwell Publishing Ltd.
2009-06-01
energy demand is projected to outgrow afford- able supplies even after accounting for the impact of anticipated energy efficiency and management ... management . The purpose of that change would be to facilitate development of a suite of ultra-low- energy solutions that would approach NZE usage by...enabling real-time op- timization of power supply, demand, and storage management for Army facilities, emplacements, or fixed installations of any
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1988-08-01
This study is part of a three-phased demonstration program to reduce energy consumption in hospitals through practical life-cycle/cost-effective modifications and alterations. Funds for the demonstration program are being provided by the American Hospital Association (AHA), the Department of Energy (DOE), and the Department of Health and Human Services (DHHS). A thorough study and evaluation of all building systems is made to identify the most cost effective approaches to energy conservation. The primary objective of the study is to investigate and analyze energy usage of the facility and to identify all life cycle, cost-effective changes required to effect a reduction inmore » energy consumption. On November 2, 1987, Consulting Consortium, Inc., was instructed to proceed with this analysis. Initial meetings were arranged with the hospital administrators to convey the purpose of the study and to request utility billing data, small scale floor plans of the facility, and to arrange for engineering walk-through surveys. The survey at St. Anthony was initiated on December 8, 1987. This report summarizes the findings together with data and information gathered during the course of that visit and other subsequent visits. This report describes the architectural, mechanical and electrical systems of the Saint Anthony Hospital. In addition, an analysis of the base year energy usage as derived from utility bills and statement of the current energy consumption trends for the hospital, and a list of recommendations for reducing energy consumption is included.« less
Evaluation of Miscellaneous and Electronic Device Energy Use in Hospitals
DOE Office of Scientific and Technical Information (OSTI.GOV)
Black, Douglas R.; Lanzisera, Steven M.; Lai, Judy
2012-09-01
Miscellaneous and electronic loads (MELs) consume about one-thirdof the primary energy used in US buildings, and their energy use is increasing faster than other end-uses. In healthcare facilities, 30percent of the annual electricity was used by MELs in 2008. This paper presents methods and challenges for estimating medical MELs energy consumption along with estimates of energy use in a hospital by combining device-level metered data with inventories and usage information. An important finding is that common, small devices consume large amounts of energy in aggregate and should not be ignored when trying to address hospital energy use.
Evaluation and Selection of Renewable Energy Technologies for Highway Maintenance Facilities
NASA Astrophysics Data System (ADS)
Andrews, Taylor
The interest in renewable energy has been increasing in recent years as attempts to reduce energy costs as well the consumption of fossil fuels are becoming more common. Companies and organizations are recognizing the increasing reliance on limited fossil fuels' resources, and as competition and costs for these resources grow, alternative solutions are becoming more appealing. Many federally run buildings and associations also have the added pressure of meeting the mandates of federal energy policies that dictate specific savings or reductions. Federal highway maintenance facilities run by the Department of Transportation fall into this category. To help meet energy saving goals, an investigation into potential renewable energy technologies was completed for the Ohio Department of Transportation. This research examined several types of renewable energy technologies and the major factors that affect their performance and evaluated their potential for implementation at highway maintenance facilities. Facilities energy usage data were provided, and a facility survey and site visits were completed to enhance the evaluation of technologies and the suitability for specific projects. Findings and technology recommendations were presented in the form of selection matrices, which were designed to help make selections in future projects. The benefits of utilization of other tools such as analysis software and life cycle assessments were also highlighted. These selection tools were designed to be helpful guides when beginning the pursuit of a renewable energy technology for highway maintenance facilities, and can be applied to other similar building types and projects. This document further discusses the research strategies and findings as well as the recommendations that were made to the personnel overseeing Ohio's highway maintenance facilities.
Accelerator Facilities for Radiation Research
NASA Technical Reports Server (NTRS)
Cucinotta, Francis A.
1999-01-01
HSRP Goals in Accelerator Use and Development are: 1.Need for ground-based heavy ion and proton facility to understand space radiation effects discussed most recently by NAS/NRC Report (1996). 2. Strategic Program Goals in facility usage and development: -(1) operation of AGS for approximately 600 beam hours/year; (2) operation of Loma Linda University (LLU) proton facility for approximately 400 beam hours/year; (3) construction of BAF facility; and (4) collaborative research at HIMAC in Japan and with other existing or potential international facilities. 3. MOA with LLU has been established to provide proton beams with energies of 40-250 important for trapped protons and solar proton events. 4. Limited number of beam hours available at Brookhaven National Laboratory's (BNL) Alternating Gradient Synchrotron (AGS).
USDA-ARS?s Scientific Manuscript database
Light-emitting diode (LED) lighting is being used in the poultry industry to reduce energy usage in broiler production facilities. However, limited data are available comparing efficacy of different spectral distribution of LED bulbs on blood physiological variables of broilers grown to heavy weight...
Energy consumption and load profiling at major airports. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kennedy, J.
1998-12-01
This report describes the results of energy audits at three major US airports. These studies developed load profiles and quantified energy usage at these airports while identifying procedures and electrotechnologies that could reduce their power consumption. The major power consumers at the airports studied included central plants, runway and taxiway lighting, fuel farms, terminals, people mover systems, and hangar facilities. Several major findings emerged during the study. The amount of energy efficient equipment installed at an airport is directly related to the age of the facility. Newer facilities had more energy efficient equipment while older facilities had much of themore » original electric and natural gas equipment still in operation. As redesign, remodeling, and/or replacement projects proceed, responsible design engineers are selecting more energy efficient equipment to replace original devices. The use of computer-controlled energy management systems varies. At airports, the primary purpose of these systems is to monitor and control the lighting and environmental air conditioning and heating of the facility. Of the facilities studied, one used computer management extensively, one used it only marginally, and one had no computer controlled management devices. At all of the facilities studied, natural gas is used to provide heat and hot water. Natural gas consumption is at its highest in the months of November, December, January, and February. The Central Plant contains most of the inductive load at an airport and is also a major contributor to power consumption inefficiency. Power factor correction equipment was used at one facility but was not installed at the other two facilities due to high power factor and/or lack of need.« less
2015-05-30
provides a smnmaty of results from the site visits and discusses areas of potential future research. 1S. SUBJECT TERMS Aircraft Paint Hangar...Airlift Wing ACCPFF ACGIH Aircraft Corrosion Control and Paint Finishing Facility American Conference of Governmental Industrial Hygienists ACS Cross...velocity did not increase exposure resulted in an interest in expanding the project to encompass more sites around the U.S. with support from the
City of Raleigh, Wilders Grove Service Center, Solid Waste Services Facility. Final Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Robert Cox; Bill Black; Battle, Fred
Final Report for DOE Grant EE0002808. Grant award was for technology demonstration of geothermal energy systems. One of the major objectives identified for the demonstration portion of the grant was to prove the viability of Ground Source Heat Pump (GSHP) systems in significantly reducing energy usage of HVAC and domestic water heating systems compared to traditional systems. Data were monitored and conclusions drawn, including estimating payback timeframes and documenting lessons learned.
2013-02-01
offutt.af.mil Designation: Final Environmental Assessment (EA) with attached Finding of No Significant Impact (FONSI) Abstract: OPPD needs a new...Evaluation 6 2.5 Summary of Potential Impacts 7 3.0 AFFECTED ENVIRONMENT 8 3.1 Location 8 3.2 History and Current Mission of Installation 8...4.2.10 Energy Usage and Alternative Energy Sources 19 4.1.11 Cultural Resources 19 4.3 Cumulative Impacts 19 5.0
USDA-ARS?s Scientific Manuscript database
A plant trial was conducted at a 54 MGPY dry grind fuel ethanol facility to evaluate the use of enhanced water removal from whole stillage by enzyme addition during fermentation. Laboratory data had previously shown significant improvements in water removal that could potentially result in significa...
Variation in fistula use across dialysis facilities: is it explained by case-mix?
Tangri, Navdeep; Moorthi, Ranjani; Tighiouhart, Hocine; Meyer, Klemens B; Miskulin, Dana C
2010-02-01
Arteriovenous fistulas (AVFs) remain the preferred vascular access for hemodialysis patients. Dialysis facilities that fail to meet Centers for Medicare & Medicaid Services goals cite patient case-mix as a reason for low AVF prevalence. This study aimed to determine the magnitude of the variability in AVF usage across dialysis facilities and the extent to which patient case-mix explains it. The vascular access used in 10,112 patients dialyzed at 173 Dialysis Clinic Inc. facilities from October 1 to December 31, 2004, was evaluated. The access in use was considered to be an AVF if it was used for >70% of hemodialysis treatments. Mixed-effects models with a random intercept for dialysis facilities evaluated the effect of facilities on AVF usage. Sequentially adjusted multivariate models measured the extent to which patient factors (case-mix) explain variation across facilities in AVF rates. 3787 patients (38%) were dialyzed using AVFs. There was a significant facility effect: 7.6% of variation in AVF use was attributable to facility. This was reduced to 7.1% after case-mix adjustment. There were no identified specific facility-level factors that explained the interfacility variation. AVF usage varies across dialysis facilities, and patient case-mix did not reduce this variation. In this study, 92% of the total variation in AVF usage was due to patient factors, but most were not measurable. A combination of patient factors and process indicators should be considered in adjudicating facility performance for this quality indicator.
Ubiquitous Green Computing Techniques for High Demand Applications in Smart Environments
Zapater, Marina; Sanchez, Cesar; Ayala, Jose L.; Moya, Jose M.; Risco-Martín, José L.
2012-01-01
Ubiquitous sensor network deployments, such as the ones found in Smart cities and Ambient intelligence applications, require constantly increasing high computational demands in order to process data and offer services to users. The nature of these applications imply the usage of data centers. Research has paid much attention to the energy consumption of the sensor nodes in WSNs infrastructures. However, supercomputing facilities are the ones presenting a higher economic and environmental impact due to their very high power consumption. The latter problem, however, has been disregarded in the field of smart environment services. This paper proposes an energy-minimization workload assignment technique, based on heterogeneity and application-awareness, that redistributes low-demand computational tasks from high-performance facilities to idle nodes with low and medium resources in the WSN infrastructure. These non-optimal allocation policies reduce the energy consumed by the whole infrastructure and the total execution time. PMID:23112621
Facile synthesis of nanostructured transition metal oxides as electrodes for Li-ion batteries
NASA Astrophysics Data System (ADS)
Opra, Denis P.; Gnedenkov, Sergey V.; Sokolov, Alexander A.; Minaev, Alexander N.; Kuryavyi, Valery G.; Sinebryukhov, Sergey L.
2017-09-01
At all times, energy storage is one of the greatest scientific challenge. Recently, Li-ion batteries are under special attention due to high working voltage, long cycle life, low self-discharge, reliability, no-memory effect. However, commercial LIBs usage in medium- and large-scale energy storage are limited by the capacity of lithiated metal oxide cathode and unsafety of graphite anode at high-rate charge. In this way, new electrode materials with higher electrochemical performance should be designed to satisfy a requirement in both energy and power. As it known, nanostructured transition metal oxides are promising electrode materials because of their elevated specific capacity and high potential vs. Li/Li+. In this work, the perspective of an original facile technique of pulsed high-voltage plasma discharge in synthesis of nanostructured transition metal oxides as electrodes for lithium-ion batteries has been demonstrated.
Ubiquitous green computing techniques for high demand applications in Smart environments.
Zapater, Marina; Sanchez, Cesar; Ayala, Jose L; Moya, Jose M; Risco-Martín, José L
2012-01-01
Ubiquitous sensor network deployments, such as the ones found in Smart cities and Ambient intelligence applications, require constantly increasing high computational demands in order to process data and offer services to users. The nature of these applications imply the usage of data centers. Research has paid much attention to the energy consumption of the sensor nodes in WSNs infrastructures. However, supercomputing facilities are the ones presenting a higher economic and environmental impact due to their very high power consumption. The latter problem, however, has been disregarded in the field of smart environment services. This paper proposes an energy-minimization workload assignment technique, based on heterogeneity and application-awareness, that redistributes low-demand computational tasks from high-performance facilities to idle nodes with low and medium resources in the WSN infrastructure. These non-optimal allocation policies reduce the energy consumed by the whole infrastructure and the total execution time.
Psychotropic Drug Patterns in a Large ICF/MR Facility: A Ten-Year Experience.
ERIC Educational Resources Information Center
Poindexter, Ann R.
1989-01-01
Psychotropic drug-prescribing patterns for 474 adults with mental retardation residing at an intermediate-care facility were examined for a 10-year period. Results indicated a progressive, marked decrease in total psychotropic drug usage and changes in the type of drugs prescribed with overall decline in drug usage. (Author/DB)
Electricity end use demand study for Egypt
DOE Office of Scientific and Technical Information (OSTI.GOV)
Turiel, I.; Lebot, B.; Nadel, S.
1990-12-01
This report describes the results of a study undertaken by Lawrence Berkeley Laboratory (LBL) to develop an approach for reducing electricity demand in the residential sector in Egypt. A team with expertise in appliance energy usage, appliance manufacturing, appliance testing, and energy analysis was assembled to work on this project. The team visited Egypt during the month of March 1990. They met with the Egyptian Organization for Energy Planning (OEP) and with many other parties. They also visited eleven appliance manufacturing facilities. The project tasks are: data gathering and analysis; assessment of appliance manufacturing plants; demonstration of microcomputer programs; gatheringmore » of data on appliance standards and test procedures; and impact of programs to foster energy efficiency of electricity use.« less
Reducing power usage on demand
NASA Astrophysics Data System (ADS)
Corbett, G.; Dewhurst, A.
2016-10-01
The Science and Technology Facilities Council (STFC) datacentre provides large- scale High Performance Computing facilities for the scientific community. It currently consumes approximately 1.5MW and this has risen by 25% in the past two years. STFC has been investigating leveraging preemption in the Tier 1 batch farm to save power. HEP experiments are increasing using jobs that can be killed to take advantage of opportunistic CPU resources or novel cost models such as Amazon's spot pricing. Additionally, schemes from energy providers are available that offer financial incentives to reduce power consumption at peak times. Under normal operating conditions, 3% of the batch farm capacity is wasted due to draining machines. By using preempt-able jobs, nodes can be rapidly made available to run multicore jobs without this wasted resource. The use of preempt-able jobs has been extended so that at peak times machines can be hibernated quickly to save energy. This paper describes the implementation of the above and demonstrates that STFC could in future take advantage of such energy saving schemes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1988-08-01
This study is part of a three-phased demonstration project to reduce energy consumption in hospitals through practical life-cycle, cost-effective modifications and alterations. Funds for the demonstration project are provided by the American Hospital Association (AHA), the Department of Energy (DOE), and the Department of Health and Human Services (DHHS). Two hospitals in Michigan were selected for the project, Bay Medical Center in Bay City and St. Mary's Hospital in Grand Rapids. The objectives of this study, which is funded by HHS, are to investigate and analyze energy usage of the facilities and to identify all life-cycle, cost-effective changes required tomore » effect a reduction in energy consumption.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1988-08-01
This study is part of a three-phased demonstration project to reduce energy consumption in hospitals through practical life-cycle, cost-effective modifications and alterations. Funds for the demonstration project are provided by the American Hospital Association (AHA), the Department of Energy (DOE), and the Department of Health and Human Services (DHHS). Two hospitals in Michigan were selected for the project, Bay Medical Center in Bay City and St. Mary's Hospital in Ground Rapids. The objectives of this study, which is funded by HHS, are to investigate and analyze energy usage of the facilities and to identify all life-cycle, cost-effective changes required tomore » effect a reduction in energy consumption.« less
Brioschi, A; Capolongo, S; Buffoli, M
2010-01-01
The research moves from the current global and local context and from shared development strategies. From the observation and the analysis of contemporary environmental and energy issues and redefined directions of growth of human activity, it is addressing the question of environmental sustainability and energy conservation of building hospital systems. The work has developed a field survey relating the specific topic of energy saving and efficiency of the Park Hospital in the Italian Lombardy Region. This has been articulated in a diagnosis of technology and efficiency of regional hospitals, implemented through a census, and in a subsequent identification of interventional cases, in order to show its economic, environmental and health performance of the energy efficiency consumption and the environmentally sound.
Aymerich, I; Rieger, L; Sobhani, R; Rosso, D; Corominas, Ll
2015-09-15
The objective of this paper is to demonstrate the importance of incorporating more realistic energy cost models (based on current energy tariff structures) into existing water resource recovery facilities (WRRFs) process models when evaluating technologies and cost-saving control strategies. In this paper, we first introduce a systematic framework to model energy usage at WRRFs and a generalized structure to describe energy tariffs including the most common billing terms. Secondly, this paper introduces a detailed energy cost model based on a Spanish energy tariff structure coupled with a WRRF process model to evaluate several control strategies and provide insights into the selection of the contracted power structure. The results for a 1-year evaluation on a 115,000 population-equivalent WRRF showed monthly cost differences ranging from 7 to 30% when comparing the detailed energy cost model to an average energy price. The evaluation of different aeration control strategies also showed that using average energy prices and neglecting energy tariff structures may lead to biased conclusions when selecting operating strategies or comparing technologies or equipment. The proposed framework demonstrated that for cost minimization, control strategies should be paired with a specific optimal contracted power. Hence, the design of operational and control strategies must take into account the local energy tariff. Copyright © 2015 Elsevier Ltd. All rights reserved.
Renewable energy sources in Bulgaria: Current state and trends
NASA Astrophysics Data System (ADS)
Kolev, K.
The over-dependency of Bulgaria on imported fuel stressed the importance of developing a new energy strategy based on energy saving which includes also using renewable energy sources (RES). The target is the substitution of at least 2 percent of the real primary energy consumption with RES by 2010. The author gives a generalized analysis of the available RES in Bulgaria -solar, wind, geothermal, biomass and mini-hydraulic. The potentialities of each source for its usage as a suitable energy supply are pointed out, as well as the current status of research and implementation work, problems connected with legislation, financing and production of particular facilities. The governmental policy concerning RES is considered briefly. A description is given to the project 'Technical and Economical Assessment of Possibilities for Expansion of the RES-part in the Energy Balance of the Country' developed and started in 1994 in the framework of the PHARE program.
Measuring clinical outcomes of animal-assisted therapy: impact on resident medication usage.
Lust, Elaine; Ryan-Haddad, Ann; Coover, Kelli; Snell, Jeff
2007-07-01
To measure changes in medication usage of as-needed, psychoactive medications and other select as-needed medication usage as a result of a therapy dog residing in the rehabilitation facility. Additional measures are participants' thoughts and feelings on quality-of-life factors. One group, pretest, post-test. Residential rehabilitation facility. Convenience sample, N = 58 residents living at the facility. A certified, trained therapy dog. Changes in as-needed medication usage for the following categories: analgesics, psychoactive medications, and laxatives, as well as changes in vital sign measurements of blood pressure, pulse, respiration rate, and body weight. Additionally, changes in the residents' perception of quality-of-life factors. One of the three monitored drug classes, analgesia, revealed a decrease in medication usage (mean = 2.6, standard deviation [SD] +/- 6.90, P = 0.017), and one of four monitored vital signs, pulse, showed a decrease (mean = 5.8, SD +/-7.39, P = 0.000) in study participants exposed to the therapy dog. Positive changes were reported in study participants' quality of life. The benefits to human welfare as a result of the presence of a therapy dog have the potential to decrease medication usage for certain conditions in long-term care patients as well as decrease costs. Pharmacist involvement in animal-assisted therapy has the potential to make unique and measurable improvements to best patient care.
(Updated) Fort Detrick Gate Hours Change Effective April 10 | Poster
The Fort Detrick gate hours will change beginning Friday, April 10. The new hours were recently provided by the U.S. Army Garrison (USAG), Fort Detrick. NCI will continue to work with the USAG to address questions that may arise. Note that no changes have been made for facilities outside of the Fort Detrick campus (e.g., the Advanced Technology Research Facility).
Specification of Energy Assessment Methodologies to Satisfy ISO 50001 Energy Management Standard
NASA Astrophysics Data System (ADS)
Kanneganti, Harish
Energy management has become more crucial for industrial sector as a way to lower their cost of production and in reducing their carbon footprint. Environmental regulations also force the industrial sector to increase the efficiency of their energy usage. Hence industrial sector started relying on energy management consultancies for improvements in energy efficiency. With the development of ISO 50001 standard, the entire energy management took a new dimension involving top level management and getting their commitment on energy efficiency. One of the key requirements of ISO 50001 is to demonstrate continual improvement in their (industry) energy efficiency. The major aim of this work is to develop an energy assessment methodology and reporting format to tailor the needs of ISO 50001. The developed methodology integrates the energy reduction aspect of an energy assessment with the requirements of sections 4.4.3 (Energy Review) to 4.4.6 (Objectives, Targets and Action Plans) in ISO 50001 and thus helping the facilities in easy implementation of ISO 50001.
Multi-national findings on radiation protection of children.
Rehani, Madan M
2014-10-01
This article reviews issues of radiation protection in children in 52 low-resource countries. Extensive information was obtained through a survey by the International Atomic Energy Agency (IAEA); wide-ranging information was available from 40 countries and data from the other countries pertained to frequency of pediatric CT examinations. Of note is that multi-detector CT (MDCT) was available in 77% of responses to the survey, typically nodal centers in these countries. Nearly 75% of these scanners were reported to have dose displays. The pediatric CT usage was lower in European facilities as compared to Asian and African facilities, where usage was twice as high. The most frequently scanned body part was the head. Frequent use of 120 kVp was reported in children. The ratio of maximum to minimum CT dose index volume (CTDIvol) values varied between 15 for abdomen CT in the age group 5-10 years and 100 for chest CT in the age group <1 year. In 8% of the CT systems, CTDI values for pediatric patients were higher than those for adults in at least one age group and for one type of examination. Use of adult protocols for children was associated with CTDIw or CTDIvol values in children that were double those of adults for head and chest examination and 50% higher for abdomen examination. Patient dose records were kept in nearly half of the facilities, with the highest frequency in Europe (55% of participating facilities), and in 49% of Asian, 36% of Latin American and 14% of African facilities. The analysis of the first-choice examinations in seven clinical conditions showed that practice was in accordance with guidelines for only three of seven specified clinical conditions.
ACMV Energy Analysis for Academic Building: A Case Study
NASA Astrophysics Data System (ADS)
Hywel, R.; Tee, B. T.; Arifin, M. Y.; Tan, C. F.; Gan, C. K.; Chong, CT
2015-09-01
Building energy audit examines the ways actual energy consumption is currently used in the facility, in the case of a completed and occupied building and identifies some alternatives to reduce current energy usage. Implementation of energy audit are practically used to analyze energy consumption pattern, monitoring on how the energy used varies with time in the building, how the system element interrelate, and study the effect of external environment towards building. In this case study, a preliminary energy audit is focusing on Air-Conditioning & Mechanical Ventilation (ACMV) system which reportedly consumed 40% of the total energy consumption in typical building. It is also the main system that provides comfortable and healthy environment for the occupants. The main purpose of this study is to evaluate the current ACMV system performance, energy optimization and identifying the energy waste on UTeM's academic building. To attain this, the preliminary data is collected and then analyzed. Based on the data, economic analysis will be determined before cost-saving methods are being proposed.
Asah, Flora
2013-04-01
This study discusses factors inhibiting computer usage for work-related tasks among computer-literate professional nurses within rural healthcare facilities in South Africa. In the past two decades computer literacy courses have not been part of the nursing curricula. Computer courses are offered by the State Information Technology Agency. Despite this, there seems to be limited use of computers by professional nurses in the rural context. Focus group interviews held with 40 professional nurses from three government hospitals in northern KwaZulu-Natal. Contributing factors were found to be lack of information technology infrastructure, restricted access to computers and deficits in regard to the technical and nursing management support. The physical location of computers within the health-care facilities and lack of relevant software emerged as specific obstacles to usage. Provision of continuous and active support from nursing management could positively influence computer usage among professional nurses. A closer integration of information technology and computer literacy skills into existing nursing curricula would foster a positive attitude towards computer usage through early exposure. Responses indicated that change of mindset may be needed on the part of nursing management so that they begin to actively promote ready access to computers as a means of creating greater professionalism and collegiality. © 2011 Blackwell Publishing Ltd.
Energy survey study and report of hospitals in Chicago: South Suburban Hospital: Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1988-08-01
This study is part of a three-phased demonstration project to reduce energy consumption in hospitals through practical life-cycle/cost-effective modifications and alteration. Funds for the demonstration project are provided by the American Hospital Association (AHA), the Department of Energy (DOE), and the Department of Health and Human Services (DHHS). A thorough study and evaluation of all building systems is made to identify opportunities for reduction in energy consumption and to determine the most cost effective approaches to energy conservation. The primary objective of the study is to investigate and analyze energy usage of the facility and to identify all life cycle,more » cost-effective changes required to effect a reduction in energy consumption. For the purpose of economic evaluation of the energy conservation projects identified, life-cycle cost and simple payback periods are used. Energy conservation measures with simple payback periods exceeding five years were dismissed from further detailed study.« less
Energy Consumption Information Services for Smart Home Inhabitants
NASA Astrophysics Data System (ADS)
Schwanzer, Michael; Fensel, Anna
We investigate services giving users an adequate insight on his or her energy consumption habits in order to optimize it in the long run. The explored energy awareness services are addressed to inhabitants of smart homes, equipped with smart meters, advanced communication facilities, sensors and actuators. To analyze the potential of such services, a game at a social network Facebook has been designed and implemented, and the information about players' responses and interactions within the game environment has been collected and analyzed. The players have had their virtual home energy usage visualized in different ways, and had to optimize the energy consumption basing on their own perceptions of the consumption information. Evaluations reveal, in particular, that users are specifically responsive to information shown as a real-time graph and as costs in Euro, and are able to produce and share with each other policies for managing their smart home environments.
Development and applications of nondestructive evaluation at Marshall Space Flight Center
NASA Technical Reports Server (NTRS)
Whitaker, Ann F.
1990-01-01
A brief description of facility design and equipment, facility usage, and typical investigations are presented for the following: Surface Inspection Facility; Advanced Computer Tomography Inspection Station (ACTIS); NDE Data Evaluation Facility; Thermographic Test Development Facility; Radiographic Test Facility; Realtime Radiographic Test Facility; Eddy Current Research Facility; Acoustic Emission Monitoring System; Advanced Ultrasonic Test Station (AUTS); Ultrasonic Test Facility; and Computer Controlled Scanning (CONSCAN) System.
42 CFR 483.450 - Condition of participation: Client behavior and facility practices.
Code of Federal Regulations, 2010 CFR
2010-10-01
... LONG TERM CARE FACILITIES Conditions of Participation for Intermediate Care Facilities for the Mentally... quickly as possible, and a record of these checks and usage must be kept. (5) Restraints must be designed...
42 CFR 483.450 - Condition of participation: Client behavior and facility practices.
Code of Federal Regulations, 2013 CFR
2013-10-01
... LONG TERM CARE FACILITIES Conditions of Participation for Intermediate Care Facilities for Individuals... and usage must be kept. (5) Restraints must be designed and used so as not to cause physical injury to...
42 CFR 483.450 - Condition of participation: Client behavior and facility practices.
Code of Federal Regulations, 2012 CFR
2012-10-01
... LONG TERM CARE FACILITIES Conditions of Participation for Intermediate Care Facilities for Individuals... and usage must be kept. (5) Restraints must be designed and used so as not to cause physical injury to...
42 CFR 483.450 - Condition of participation: Client behavior and facility practices.
Code of Federal Regulations, 2011 CFR
2011-10-01
... LONG TERM CARE FACILITIES Conditions of Participation for Intermediate Care Facilities for the Mentally... quickly as possible, and a record of these checks and usage must be kept. (5) Restraints must be designed...
42 CFR 483.450 - Condition of participation: Client behavior and facility practices.
Code of Federal Regulations, 2014 CFR
2014-10-01
... LONG TERM CARE FACILITIES Conditions of Participation for Intermediate Care Facilities for Individuals... and usage must be kept. (5) Restraints must be designed and used so as not to cause physical injury to...
Tough photoluminescent hydrogels doped with lanthanide.
Wang, Mei Xiang; Yang, Can Hui; Liu, Zhen Qi; Zhou, Jinxiong; Xu, Feng; Suo, Zhigang; Yang, Jian Hai; Chen, Yong Mei
2015-03-01
Photoluminescent hydrogels have emerged as novel soft materials with potential applications in many fields. Although many photoluminescent hydrogels have been fabricated, their scope of usage has been severely limited by their poor mechanical performance. Here, a facile strategy is reported for preparing lanthanide (Ln)-alginate/polyacrylamide (PAAm) hydrogels with both high toughness and photoluminescence, which has been achieved by doping Ln(3+) ions (Ln = Eu, Tb, Eu/Tb) into alginate/PAAm hydrogel networks, where Ln(3+) ions serve as both photoluminescent emitters and physical cross-linkers. The resulting hydrogels exhibit versatile advantages including excellent mechanical properties (∼ MPa strength, ≈ 20 tensile strains, ≈ 10(4) kJ m(-3) energy dissipation), good photoluminescent performance, tunable emission color, excellent processability, and cytocompatibility. The developed tough photoluminescent hydrogels hold great promises for expanding the usage scope of hydrogels. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
1980-08-01
orientation, and HVAC systems have on three Army buildings in five different climatic regions. f Optimization of EnerV Usage in Military Facilities...The clinic’s environment is maintained by a multizone air-handling unit served by its own boiler and chiller . The building was modeled with 30... setpoints for the space temperature. This type of throttling range allows the heating system to control around a throttling range of 67 to 69oF (19 to 200
Energy index decomposition methodology at the plant level
NASA Astrophysics Data System (ADS)
Kumphai, Wisit
Scope and method of study. The dissertation explores the use of a high level energy intensity index as a facility-level energy performance monitoring indicator with a goal of developing a methodology for an economically based energy performance monitoring system that incorporates production information. The performance measure closely monitors energy usage, production quantity, and product mix and determines the production efficiency as a part of an ongoing process that would enable facility managers to keep track of and, in the future, be able to predict when to perform a recommissioning process. The study focuses on the use of the index decomposition methodology and explored several high level (industry, sector, and country levels) energy utilization indexes, namely, Additive Log Mean Divisia, Multiplicative Log Mean Divisia, and Additive Refined Laspeyres. One level of index decomposition is performed. The indexes are decomposed into Intensity and Product mix effects. These indexes are tested on a flow shop brick manufacturing plant model in three different climates in the United States. The indexes obtained are analyzed by fitting an ARIMA model and testing for dependency between the two decomposed indexes. Findings and conclusions. The results concluded that the Additive Refined Laspeyres index decomposition methodology is suitable to use on a flow shop, non air conditioned production environment as an energy performance monitoring indicator. It is likely that this research can be further expanded in to predicting when to perform a recommissioning process.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chang, Y.L.; Grot, R.A.
1980-10-01
The measured energy consumption and usage characteristics for household dishwashers, clothes washers, and clothes dryers for ten townhouses at Twin Rivers, N.J., are presented. Whenever the dishwashers and/or clothes washers were in use, the energy consumption, water consumption, frequency of usage, and water temperature were measured by a data acquisition system. The electrical energy of electric clothes dryers and the gas consumption of gas clothes dryers were measured, as well as their frequency and duration of use, and exhaust temperature. Typical household usage patterns of these major appliances are included.
Facility Benchmarking Trends in Tertiary Education - An Australian Case Study.
ERIC Educational Resources Information Center
Fisher, Kenn
2001-01-01
Presents how Australia's facility managers are responding to the growing impact of tertiary education participation and the increase in educational facility usage. Topics cover strategic asset management and the benchmarking of education physical assets and postsecondary institutions. (GR)
Commercial Building Tenant Energy Usage Aggregation and Privacy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Livingston, Olga V.; Pulsipher, Trenton C.; Anderson, David M.
A growing number of building owners are benchmarking their building energy use. This requires the building owner to acquire monthly whole-building energy usage information, which can be challenging for buildings in which individual tenants have their own utility meters and accounts with the utility. Some utilities and utility regulators have turned to aggregation of customer energy use data (CEUD) as a way to give building owners whole-building energy usage data while protecting customer privacy. Meter profile aggregation adds a layer of protection that decreases the risk of revealing CEUD as the number of meters aggregated increases. The report statistically characterizesmore » the similarity between individual energy usage patterns and whole-building totals at various levels of meter aggregation.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wilder, Todd; Moragne, Corliss L.
The City of Tallahassee's Innovative Energy Initiatives program sought, first, to evaluate customer response and acceptance to in-home Smart Meter-enabled technologies that allow customers intelligent control of their energy usage. Additionally, this project is in furtherance of the City of Tallahassee's ongoing efforts to expand and enhance the City's Smart Grid capacity and give consumers more tools with which to effectively manage their energy consumption. This enhancement would become possible by establishing an "operations or command center" environment that would be designed as a dual use facility for the City's employees - field and network staff - and systems responsiblemore » for a Smart Grid network. A command center would also support the City's Office of Electric Delivery and Energy Reliability's objective to overcome barriers to the deployment of new technologies that will ensure a truly modern and robust grid capable of meeting the demands of the 2151 century.« less
A Novel Sensor Platform Matching the Improved Version of IPMVP Option C for Measuring Energy Savings
Tseng, Yen-Chieh; Lee, Da-Sheng; Lin, Cheng-Fang; Chang, Ching-Yuan
2013-01-01
It is easy to measure energy consumption with a power meter. However, energy savings cannot be directly computed by the powers measured using existing power meter technologies, since the power consumption only reflects parts of the real energy flows. The International Performance Measurement and Verification Protocol (IPMVP) was proposed by the Efficiency Valuation Organization (EVO) to quantify energy savings using four different methodologies of A, B, C and D. Although energy savings can be estimated following the IPMVP, there are limitations on its practical implementation. Moreover, the data processing methods of the four IPMVP alternatives use multiple sensors (thermometer, hygrometer, Occupant information) and power meter readings to simulate all facilities, in order to determine an energy usage benchmark and the energy savings. This study proposes a simple sensor platform to measure energy savings. Using usually the Electronic Product Code (EPC) global standard, an architecture framework for an information system is constructed that integrates sensors data, power meter readings and occupancy conditions. The proposed sensor platform is used to monitor a building with a newly built vertical garden system (VGS). A VGS shields solar radiation and saves on energy that would be expended on air-conditioning. With this platform, the amount of energy saved in the whole facility is measured and reported in real-time. The data are compared with those obtained from detailed measurement and verification (M&V) processes. The discrepancy is less than 1.565%. Using measurements from the proposed sensor platform, the energy savings for the entire facility are quantified, with a resolution of ±1.2%. The VGS gives an 8.483% daily electricity saving for the building. Thus, the results show that the simple sensor platform proposed by this study is more widely applicable than the four complicated IPMVP alternatives and the VGS is an effective tool in reducing the carbon footprint of a building. PMID:23698273
38 CFR 17.501 - Confidential and privileged documents.
Code of Federal Regulations, 2012 CFR
2012-07-01
... facility: (i) Medical records reviews, (ii) Drug usage evaluations, (iii) Blood usage reviews, (iv... quality assurance reviews. (e) Documents which are confidential and privileged may be in written, computer... of Boards of Investigations; (5) Completed patient satisfaction survey questionnaires and findings...
38 CFR 17.501 - Confidential and privileged documents.
Code of Federal Regulations, 2014 CFR
2014-07-01
... facility: (i) Medical records reviews, (ii) Drug usage evaluations, (iii) Blood usage reviews, (iv... quality assurance reviews. (e) Documents which are confidential and privileged may be in written, computer... of Boards of Investigations; (5) Completed patient satisfaction survey questionnaires and findings...
38 CFR 17.501 - Confidential and privileged documents.
Code of Federal Regulations, 2010 CFR
2010-07-01
... facility: (i) Medical records reviews, (ii) Drug usage evaluations, (iii) Blood usage reviews, (iv... quality assurance reviews. (e) Documents which are confidential and privileged may be in written, computer... of Boards of Investigations; (5) Completed patient satisfaction survey questionnaires and findings...
38 CFR 17.501 - Confidential and privileged documents.
Code of Federal Regulations, 2011 CFR
2011-07-01
... facility: (i) Medical records reviews, (ii) Drug usage evaluations, (iii) Blood usage reviews, (iv... quality assurance reviews. (e) Documents which are confidential and privileged may be in written, computer... of Boards of Investigations; (5) Completed patient satisfaction survey questionnaires and findings...
38 CFR 17.501 - Confidential and privileged documents.
Code of Federal Regulations, 2013 CFR
2013-07-01
... facility: (i) Medical records reviews, (ii) Drug usage evaluations, (iii) Blood usage reviews, (iv... quality assurance reviews. (e) Documents which are confidential and privileged may be in written, computer... of Boards of Investigations; (5) Completed patient satisfaction survey questionnaires and findings...
Walking at non-constant speeds: mechanical work, pendular transduction, and energy congruity.
Balbinot, G
2017-05-01
Although almost half of all walking bouts in urban environments consist of less than 12 consecutive steps and several day-to-day gait activities contain transient gait responses, in most studies gait analysis is performed at steady-state. This study aimed to analyze external (W ext ) and internal mechanical work (W int ), pendulum-like mechanics, and elastic energy usage during constant and non-constant speeds. The mechanical work, pendular transduction, and energy congruity (an estimate of storage and release of elastic energy) during walking were computed using two force platforms. We found that during accelerating gait (+NCS) energy recovery is maintained, besides extra W + ext , for decelerating gait (-NCS) poor energy recovery was counterbalanced by W - ext and C% predominance. We report an increase in elastic energy usage with speed (4-11%). Both W - ext and %C suggests that elastic energy usage is higher at faster speeds and related to -NCS (≈20% of elastic energy usage). This study was the first to show evidences of elastic energy usage during constant and non-constant speeds. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Design and development of hybrid energy generator (photovoltaics) with solar tracker
NASA Astrophysics Data System (ADS)
Mohiuddin, A. K. M.; Sabarudin, Mohamad Syabil Bin; Khan, Ahsan Ali; Izan Ihsan, Sany
2017-03-01
This paper is the outcome of a small scale hybrid energy generator (hydro and photovoltaic) project. It contains the photovoltaics part of the project. The demand of energy resources is increasing day by day. That is why people nowadays tend to move on and changes their energy usage from using fossil fuels to a cleaner and green energy like hydro energy, solar energy etc. Nevertheless, energy is hard to come by for people who live in remote areas and also campsites in the remote areas which need continuous energy sources to power the facilities. Thus, the purpose of this project is to design and develop a small scale hybrid energy generator to help people that are in need of power. This main objective of this project is to develop and analyze the effectiveness of solar trackers in order to increase the electricity generation from solar energy. Software like Solidworks and Arduino is used to sketch and construct the design and also to program the microcontroller respectively. Experimental results show the effectiveness of the designed solar tracker sytem.
[Usage survey of care equipment in care service facilities for the elderly].
Iwakiri, Kazuyuki; Takahashi, Masaya; Sotoyama, Midori; Hirata, Mamoru; Hisanaga, Naomi
2007-01-01
Musculoskeletal disorders(MSD)have been increasing recently among care workers. Since providing care workers with appropriate equipment is effective for preventing MSD, we conducted a questionnaire survey in two nursing homes and a healthcare facility for the elderly to clarify equipment usage, problems and points for improvement. A total of 81 care workers(average age 32.2 yr; 63 females, 18 males)participated in the survey. The average number of residents and the average resident's care level were 70.0 and 3.6, respectively. Wheelchair and height adjustable beds were fully available and always used in all facilities. Portable lifts, ceiling lifts and transfer boards were, however, few in all 3 facilities and the proportion of use was 14.8%, 16.0%, and 23.5%, respectively. Participants reported that it is time consuming to move residents from place to place with lifts and there is a danger of dropping a resident. Although approximately 90% of care workers had received education and training on care techniques, the workload on the low back was found to be great. Therefore, we thought that care workers must consistently use care equipment. To achieve such increased usage, we must improve the usability of the equipment.
Energy drink and other substance use among adolescent and young adult emergency department patients.
Cotter, Bradford V; Jackson, Deidrya A E; Merchant, Roland C; Babu, Kavita M; Baird, Janette R; Nirenberg, Ted; Linakis, James G
2013-10-01
This study aimed to understand current patterns of energy drink use and compare the extent of usage of energy drinks and other commonly used and misused substances between adolescent (13-17-years-old) and young adult (18-25-years-old) emergency department (ED) patients. During a 6-week period between June and August 2010, all patients presenting to an adult or pediatric ED were asked to complete a computer-based, anonymous questionnaire regarding use of energy drinks and other substances. Wilcoxon rank-sum, 2-sample tests of binomial proportions, Pearson χ(2) testing, and regression models were used to compare energy drink and substance use by age groups. Past 30-day energy drink use was greater for young adults (57.9%) than adolescents (34.9%) (P < 0.03). Adolescents typically consumed a mean of 1.5 and young adults a mean of 2.6 energy drinks per day when using energy drinks and drank at most a mean of 2.4 and 2.6 drinks per day, respectively. Among adolescents, energy drink usage was more common than alcohol, "street" or illicit drugs, and tobacco usage, but less common than caffeine product usage. For young adults, energy drink usage was more common than "street" or illicit drugs, but less common than caffeine use, and similar to tobacco and alcohol usage. Young adult energy drink users were more likely than young adult non-energy drink users also to use tobacco and caffeine. Energy drink use is common among ED patients. Given the high prevalence of energy drink use observed, emergency physicians should consider the involvement of energy drinks in the presentations of young people.
Young people's use of sports facilities: a Norwegian study on physical activity.
Limstrand, Torgeir; Rehrer, Nancy J
2008-07-01
In recent years, sports facilities have formed part of Norwegian public health policies to increase physical activity among children and adolescents. Despite large sums of public money being spent on such facilities, information on usage is limited. Our aim was to study the effects of gender, age and relative activity level on young people's use of sports facilities. We explored 662 young people's (age 6-16 years) usage of 19 different kinds of sports facilities. A questionnaire was administered to students and teachers, and situation plots of students at recess were made. The findings indicate that sports facilities in general were less used by girls, adolescents (14-16 years) and the least active (physically active < or = 1 times/week outside school) than by boys, children (6-13 years) and the most active (physically active > or = 4 times/ week outside school). More general, multifunctional facilities were used to a greater extent than specialized facilities, particularly by the least active. Distance to facility was important for the use of common facilities. These results raise the question of whether sports facilities significantly increase physical activity among "all'' young people, which is the government's stated goal. More research on sports facilities use and physical activity levels among males and females of all ages is warranted.
Facilities Management via Computer: Information at Your Fingertips.
ERIC Educational Resources Information Center
Hensey, Susan
1996-01-01
Computer-aided facilities management is a software program consisting of a relational database of facility information--such as occupancy, usage, student counts, etc.--attached to or merged with computerized floor plans. This program can integrate data with drawings, thereby allowing the development of "what if" scenarios. (MLF)
Projected electric power demands for the Potomac Electric Power Company. Volume 1
DOE Office of Scientific and Technical Information (OSTI.GOV)
Estomin, S.; Kahal, M.
1984-03-01
This three-volume report presents the results of an econometric forecast of peak and electric power demands for the Potomac Electric Power Company (PEPCO) through the year 2002. Volume I describes the methodology, the results of the econometric estimations, the forecast assumptions and the calculated forecasts of peak demand and energy usage. Separate sets of models were developed for the Maryland Suburbs (Montgomery and Prince George's counties), the District of Columbia and Southern Maryland (served by a wholesale customer of PEPCO). For each of the three jurisdictions, energy equations were estimated for residential and commercial/industrial customers for both summer and wintermore » seasons. For the District of Columbia, summer and winter equations for energy sales to the federal government were also estimated. Equations were also estimated for street lighting and energy losses. Noneconometric techniques were employed to forecast energy sales to the Northern Virginia suburbs, Metrorail and federal government facilities located in Maryland.« less
Residential Energy Consumption Survey (RECS)
2028-01-01
EIA administers the Residential Energy Consumption Survey (RECS) to a nationally representative sample of housing units. Traditionally, specially trained interviewers collect energy characteristics on the housing unit, usage patterns, and household demographics. Data include energy costs and usage for heating, cooling, appliances and other end uses.
Performance Contracting and Energy Efficiency in the State Government Market
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bharvirkar, Ranjit; Goldman, Charles; Gilligan, Donald
There is growing interest in energy efficiency (EE) among state policymakers as a result of increasing environmental concerns, rising electricity and natural gas prices, and lean economic times that motivate states to look more aggressively for cost-saving opportunities in public sector buildings. One logical place for state policymakers to demonstrate their commitment to energy efficiency is to 'lead by example' by developing and implementing strategies to reduce the energy consumption of state government facilities through investments in energy efficient technologies. Traditionally, energy efficiency improvements at state government facilities are viewed as a subset in the general category of building maintenancemore » and construction. These projects are typically funded through direct appropriations. However, energy efficiency projects are often delayed or reduced in scope whereby not all cost-effective measures are implemented because many states have tight capital budgets. Energy Savings Performance Contracting (ESPC) offers a potentially useful strategy for state program and facility managers to proactively finance and develop energy efficiency projects. In an ESPC project, Energy Service Companies (ESCOs) typically guarantee that the energy and cost savings produced by the project will equal or exceed all costs associated with implementing the project over the term of the contract. ESCOs typically provide turnkey design, installation, and maintenance services and also help arrange project financing. Between 1990 and 2006, U.S. ESCOs reported market activity of {approx}$28 Billion, with about {approx}75-80% of that activity concentrated in the institutional markets (K-12 schools, colleges/universities, state/local/federal government and hospitals). In this study, we review the magnitude of energy efficiency investment in state facilities and identify 'best practices' while employing performance contracting in the state government sector. The state government market is defined to include state offices, state universities, correctional facilities, and other state facilities. This study is part of a series of reports prepared by Lawrence Berkeley National Laboratory (LBNL) and the National Association of Energy Services Companies (NAESCO) on the ESCO market and industry trends. The scope of previous reports was much broader: Goldman et al. (2002) analyzed ESCO project costs and savings in public and private sector facilities, Hopper et al. (2005) focused on ESCO project activity in all public and institutional sectors, while Hopper et al (2007) provided aggregate results of a comprehensive survey of ESCOs on current industry activity and future prospects. We decided to focus the current study on ESCO and energy efficiency activity and potential market barriers in the state government market because previous studies suggested that this institutional sector has significant remaining energy efficiency opportunities. Moreover, ESCO activity in the state government market has lagged behind other institutional markets (e.g., K-12 schools, local governments, and the federal market). Our primary objectives were as follows: (1) Assess existing state agency energy information and data sources that could be utilized to develop performance metrics to assess progress among ESPC programs in states; (2) Conduct a comparative review of the performance of selected state ESPC programs in reducing energy usage and costs in state government buildings; and (3) Delineate the extent to which state government sector facilities are implementing energy efficiency projects apart from ESPC programs using other strategies (e.g. utility ratepayer-funded energy efficiency programs, loan funds).« less
Pinellas Plant Environmental Baseline Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
The Pinellas Plant has been part of the Department of Energy`s (DOE) nuclear weapons complex since the plant opened in 1957. In March 1995, the DOE sold the Pinellas Plant to the Pinellas County Industry Council (PCIC). DOE has leased back a large portion of the plant site to facilitate transition to alternate use and safe shutdown. The current mission is to achieve a safe transition of the facility from defense production and prepare the site for alternative uses as a community resource for economic development. Toward that effort, the Pinellas Plant Environmental Baseline Report (EBR) discusses the current andmore » past environmental conditions of the plant site. Information for the EBR is obtained from plant records. Historical process and chemical usage information for each area is reviewed during area characterizations.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Van Geet, Otto
NREL has developed a methodology to prioritize which data center cooling systems could be upgraded for better efficiency based on estimated cost savings and economics. The best efficiency results are in cool or dry climates where 'free' economizer or evaporative cooling can provide most of the data center cooling. Locations with a high cost of energy and facilities with high power usage effectiveness (PUE) are also good candidates for data center cooling system upgrades. In one case study of a major cable provider's data centers, most of the sites studied had opportunities for cost-effective cooling system upgrades with payback periodmore » of 5 years or less. If the cable provider invested in all opportunities for upgrades with payback periods of less than 15 years, it could save 27% on annual energy costs.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dustin, R.
Modernization and renovation of sports facilities challenge the design team to balance a number of requirements: spectator and owner expectations, existing building and site conditions, architectural layouts, code and legislation issues, time constraints and budget issues. System alternatives are evaluated and selected based on the relative priorities of these requirements. These priorities are unique to each project. At Alexander Memorial Coliseum, project schedules, construction funds and facility usage became the priorities. The ACC basketball schedule and arrival of the Centennial Olympics dictated the construction schedule. Initiation and success of the project depended on the commitment of the design team tomore » meet coliseum funding levels established three years ago. Analysis of facility usage and system alternative capabilities drove the design team to select a system that met the project requirements and will maximize the benefits to the owner and spectators for many years to come.« less
Playground usage and physical activity levels of children based on playground spatial features.
Reimers, Anne K; Knapp, Guido
2017-01-01
Being outdoors is one of the strongest correlates of physical activity in children. Playgrounds are spaces especially designed to enable and foster physical activity in children. This study aimed to analyze the relationship between the spatial features of public playgrounds and the usage and physical activity levels of children playing in them. A quantitative, observational study was conducted of ten playgrounds in one district of a middle-sized town in Germany. Playground spatial features were captured using an audit instrument and the playground manual of the town. Playground usage and physical activity levels of children were assessed using a modified version of the System for Observing Play and Leisure Activity in Youth. Negative binomial models were used to analyze the count data. The number of children using the playgrounds and the number of children actively playing in them were higher in those with more varied facilities and without naturalness. Girls played more actively in playgrounds without multi-purpose areas. Cleanliness, esthetics, play facility quality, division of functional areas and playground size were not related to any outcome variable. Playground spatial features are related to playground usage and activity levels of the children in the playgrounds. Playgrounds should offer a wide variety of play facilities and provide spaces for diverse play activities to respond to the needs of large numbers of different children and to provide activity-friendly areas enabling their healthy development.
Proton Therapy Facility Planning From a Clinical and Operational Model.
Das, Indra J; Moskvin, Vadim P; Zhao, Qingya; Cheng, Chee-Wai; Johnstone, Peter A
2015-10-01
This paper provides a model for planning a new proton therapy center based on clinical data, referral pattern, beam utilization and technical considerations. The patient-specific data for the depth of targets from skin in each beam angle were reviewed at our center providing megavoltage photon external beam and proton beam therapy respectively. Further, data on insurance providers, disease sites, treatment depths, snout size and the beam angle utilization from the patients treated at our proton facility were collected and analyzed for their utilization and their impact on the facility cost. The most common disease sites treated at our center are head and neck, brain, sarcoma and pediatric malignancies. From this analysis, it is shown that the tumor depth from skin surface has a bimodal distribution (peak at 12 and 26 cm) that has significant impact on the maximum proton energy, requiring the energy in the range of 130-230 MeV. The choice of beam angles also showed a distinct pattern: mainly at 90° and 270°; this indicates that the number of gantries may be minimized. Snout usage data showed that 70% of the patients are treated with 10 cm snouts. The cost of proton beam therapy depends largely on the type of machine, maximum beam energy and the choice of gantry versus fixed beam line. Our study indicates that for a 4-room center, only two gantry rooms could be needed at the present pattern of the patient cohorts, thus significantly reducing the initial capital cost. In the USA, 95% and 100% of patients can be treated with 200 and 230 MeV proton beam respectively. Use of multi-leaf collimators and pencil beam scanning may further reduce the operational cost of the facility. © The Author(s) 2014.
Lackey, Jillian C; Peppley, B; Champagne, P; Maier, A
2015-08-01
A study was conducted to determine the current knowledge of biogas production and its use at municipal wastewater treatment plants (WWTPs) across North America. Information was provided by municipal WWTPs across Canada and the US. It was determined that hydrogen sulfide (H2S) and silicon (Si) compounds had sufficient variability to be of concern. The only biogas production trend that could be identified was a possible seasonal relationship with sludge input and biogas production. Secondary analysis was performed to observe trends in biogas usage in urban areas larger than 150,000 in the US and 50,000 in Canada; 66% of facilities had anaerobic digestion systems and, of those, only 35% had an energy recovery system. Climatic, population, and socio-political influences on the trends were considered. The primary conclusion was that more data is required to perform significant analyses on biogas production and composition variation. © The Author(s) 2015.
Improving Sustainability of Ion Implant Modules
NASA Astrophysics Data System (ADS)
Mayer, Jim
2011-01-01
Semiconductor fabs have long been pressured to manage capital costs, reduce energy consumption and increasingly improve efforts to recycle and recover resources. Ion implant tools have been high-profile offenders on all three fronts. They draw such large volumes of air for heat dissipation and risk reduction that historically, they are the largest consumer of cleanroom air of any process tool—and develop energy usage and resource profiles to match. This paper presents a documented approach to reduce their energy consumption and dramatically downsize on-site facilities support for cleanroom air manufacture and abatement. The combination produces significant capital expenditure savings. The case entails applying SAGS Type 1 (sub-atmospheric gas systems) toxic gas packaging to enable engineering adaptations that deliver the energy savings and cost benefits without any reduction in environmental health and safety. The paper also summarizes benefits as they relate to reducing a fabs carbon emission footprint (and longer range advantages relative to potential cap and trade programs) with existing technology.
Analysis of energy conservation alternatives for standard Army building. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hittle, D.C.; O'Brien, R.E.; Percivall, G.S.
1983-03-01
This report describes energy conservation alternatives for five standard Army building designs. By surveying maps of major Army installations and using the Integrated Facilities System, the most popular designs were determined to be a two-company, rolling-pin-shaped barracks for enlisted personnel; a Type 64 barracks; a motor repair shop; a battalion headquarters and classroom building; and an enlisted personnel mess hall. The Building Loads Analysis and System Thermodynamics (BLAST) energy-analysis computer program was used to develop baseline energy consumption for each design based on the building descriptions and calibrated by comparison with the measured energy usage of similar buildings. Once themore » baseline was established, the BLAST program was used to study energy conservation alternatives (ECAs) which could be retrofit to the existing buildings. The ECAs included closing off air-handling units, adding storm windows, adding 2 in. (0.051 m) of exterior insulation to the walls, partially blocking the windows, adding roof insulation, putting up south overhangs, installing programmable thermostats, recovering heat from exhaust fans, installing temperature economizers, replacing lights, and installing partitions between areas of differing temperature.« less
Implementation of a Water Flow Control System into the ISS'S Planned Fluids & Combustion Facility
NASA Technical Reports Server (NTRS)
Edwards, Daryl A.
2003-01-01
The Fluids and Combustion Facility (FCF) will become an ISS facility capable of performing basic combustion and fluids research. The facility consists of two independent payload racks specifically configured to support multiple experiments over the life of the ISS. Both racks will depend upon the ISS's Moderate Temperature Loop (MTL) for removing waste heat generated by the avionics and experiments operating within the racks. By using the MTL, constraints are imposed by the ISS vehicle on how the coolant resource is used. On the other hand, the FCF depends upon effective thermal control for maximizing life of the hardware and for supplying proper boundary conditions for the experiments. In the implementation of a design solution, significant factors in the selection of the hardware included ability to measure and control relatively low flow rates, ability to throttle flow within the time constraints of the ISS MTL, conserve energy usage, observe low mass and small volume requirements. An additional factor in the final design solution selection was considering how the system would respond to a loss of power event. This paper describes the method selected to satisfy the FCF design requirements while maintaining the constraints applied by the ISS vehicle.
Space station: Cost and benefits
NASA Technical Reports Server (NTRS)
1983-01-01
Costs for developing, producing, operating, and supporting the initial space station, a 4 to 8 man space station, and a 4 to 24 man space station are estimated and compared. These costs include contractor hardware; space station assembly and logistics flight costs; and payload support elements. Transportation system options examined include orbiter modules; standard and extended duration STS fights; reusable spacebased perigee kick motor OTV; and upper stages. Space station service charges assessed include crew hours; energy requirements; payload support module storage; pressurized port usage; and OTV service facility. Graphs show costs for science missions, space processing research, small communication satellites; large GEO transportation; OVT launch costs; DOD payload costs, and user costs.
Strategic Energy Management Plan for the Santa Ynez Band of Chumash Indians
DOE Office of Scientific and Technical Information (OSTI.GOV)
Davenport, Lars; Smythe, Louisa; Sarquilla, Lindsey
2015-03-27
This plan outlines the Santa Ynez Band of Chumash Indians’ comprehensive energy management strategy including an assessment of current practices, a commitment to improving energy performance and reducing overall energy use, and recommended actions to achieve these goals. Vision Statement The primary objective of the Strategic Energy Management Plan is to implement energy efficiency, energy security, conservation, education, and renewable energy projects that align with the economic goals and cultural values of the community to improve the health and welfare of the tribe. The intended outcomes of implementing the energy plan include job creation, capacity building, and reduced energy costsmore » for tribal community members, and tribal operations. By encouraging energy independence and local power production the plan will promote self-sufficiency. Mission & Objectives The Strategic Energy Plan will provide information and suggestions to guide tribal decision-making and provide a foundation for effective management of energy resources within the Santa Ynez Band of Chumash Indians (SYBCI) community. The objectives of developing this plan include; Assess current energy demand and costs of all tribal enterprises, offices, and facilities; Provide a baseline assessment of the SYBCI’s energy resources so that future progress can be clearly and consistently measured, and current usage better understood; Project future energy demand; Establish a system for centralized, ongoing tracking and analysis of tribal energy data that is applicable across sectors, facilities, and activities; Develop a unifying vision that is consistent with the tribe’s long-term cultural, social, environmental, and economic goals; Identify and evaluate the potential of opportunities for development of long-term, cost effective energy sources, such as renewable energy, energy efficiency and conservation, and other feasible supply- and demand-side options; and Build the SYBCI’s capacity for understanding, managing, and developing energy resources by identifying training, distribution of information materials, and community meeting needs and opportunities« less
Video game console usage and US national energy consumption: Results from a field-metering study
Desroches, Louis-Benoit; Greenblatt, Jeffery B.; Pratt, Stacy; ...
2014-10-23
There has been an increased in attention placed on the energy consumption of miscellaneous electronic loads in buildings by energy analysts and policymakers in recent years. The share of electricity consumed by consumer electronics in US households has increased in the last decade. Many devices, however, lack robust energy use data, making energy consumption estimates difficult and uncertain. Video game consoles are high-performance machines present in approximately half of all households and can consume a considerable amount of power. The precise usage of game consoles has significant uncertainty, however, leading to a wide range of recent national energy consumption estimates.more » We present here an analysis based on field-metered usage data, collected as part of a larger field metering study in the USA. This larger study collected data from 880 households in 2012 on a variety of devices, including 113 game consoles (the majority of which are Generation 7 consoles). From our metering, we find that although some consoles are left on nearly 24 h/day, the overall average usage is lower than many other studies have assumed, leading to a US national energy consumption estimate of 7.1 TWh in 2012. Nevertheless, there is an opportunity to reduce energy use with proper game console power management, as a substantial amount of game console usage occurs with the television turned off. The emergence of Generation 8 consoles may increase national energy consumption.« less
Video game console usage and US national energy consumption: Results from a field-metering study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Desroches, Louis-Benoit; Greenblatt, Jeffery B.; Pratt, Stacy
There has been an increased in attention placed on the energy consumption of miscellaneous electronic loads in buildings by energy analysts and policymakers in recent years. The share of electricity consumed by consumer electronics in US households has increased in the last decade. Many devices, however, lack robust energy use data, making energy consumption estimates difficult and uncertain. Video game consoles are high-performance machines present in approximately half of all households and can consume a considerable amount of power. The precise usage of game consoles has significant uncertainty, however, leading to a wide range of recent national energy consumption estimates.more » We present here an analysis based on field-metered usage data, collected as part of a larger field metering study in the USA. This larger study collected data from 880 households in 2012 on a variety of devices, including 113 game consoles (the majority of which are Generation 7 consoles). From our metering, we find that although some consoles are left on nearly 24 h/day, the overall average usage is lower than many other studies have assumed, leading to a US national energy consumption estimate of 7.1 TWh in 2012. Nevertheless, there is an opportunity to reduce energy use with proper game console power management, as a substantial amount of game console usage occurs with the television turned off. The emergence of Generation 8 consoles may increase national energy consumption.« less
Reid, Sandra D; Ramsarran, Jonathan; Brathwaite, Rachel; Lyman, Sarika; Baker, Ariane; Cornish, D'Andra C; Ganga, Stefan; Mohammed, Zahrid; Sookdeo, Avinash T; Thapelo, Cathrine K
2015-06-01
There has been little inquiry addressing whether or not concerns about adverse effects of energy drink usage are relevant in the Caribbean. This survey investigated energy drink usage and adverse consequences among tertiary level students in Trinidad and Tobago. A cross-sectional survey of 1994 students from eight institutions was conducted using a de novo questionnaire based on findings from a focus group of students. Chi-squared analyses and logistic regression were used to assess relationships between energy drink usage, adverse effects and other factors affecting energy drink use, and to verify predictors of energy drink use. Prevalence of use was 86%; 38% were current users. Males were more likely to use, used more frequently and at an earlier age. Energy drinks were used most commonly to increase energy (50%), combat sleepiness (45%) and enhance academic performance (40%), and occurred during sports (23%) and mixed with alcohol (22.2%). The majority (79.6%) consumed one energy drink per sitting; 62.2% experienced adverse effects, most commonly restlessness (22%), jolt and crash (17.1%) and tachycardia (16.6%). Awareness of adverse effects was associated with no use (p=0.004), but adverse effects were not a deterrent to continued use. Energy drink usage is prevalent among students. The use is not excessive, but associated with high rates of adverse effects and occurs in potentially dangerous situations like during exercise and with alcohol. There is a need to educate students about the potential adverse effects of energy drinks. Copyright © 2014 Ministry of Health, Saudi Arabia. Published by Elsevier Ltd. All rights reserved.
The global contribution of energy consumption by product exports from China.
Tang, Erzi; Peng, Chong
2017-06-01
This paper presents a model to analyze the mechanism of the global contribution of energy usage by product exports. The theoretical analysis is based on the perspective that contribution estimates should be in relatively smaller sectors in which the production characteristics could be considered, such as the productivity distribution for each sector. Then, we constructed a method to measure the global contribution of energy usage. The simple method to estimate the global contribution is the percentage of goods export volume compared to the GDP as a multiple of total energy consumption, but this method underestimates the global contribution because it ignores the structure of energy consumption and product export in China. According to our measurement method and based on the theoretical analysis, we calculated the global contribution of energy consumption only by industrial manufactured product exports in a smaller sector per industry or manufacturing sector. The results indicated that approximately 42% of the total energy usage in the whole economy for China in 2013 was contributed to foreign regions. Along with the primary products and service export in China, the global contribution of energy consumption for China in 2013 by export was larger than 42% of the total energy usage.
Annual Energy Usage Reduction and Cost Savings of a School: End-Use Energy Analysis
Alghoul, M. A.; Bakhtyar, B.; Asim, Nilofar; Sopian, K.
2014-01-01
Buildings are among the largest consumers of energy. Part of the energy is wasted due to the habits of users and equipment conditions. A solution to this problem is efficient energy usage. To this end, an energy audit can be conducted to assess the energy efficiency. This study aims to analyze the energy usage of a primary school and identify the potential energy reductions and cost savings. A preliminary audit was conducted, and several energy conservation measures were proposed. The energy conservation measures, with reference to the MS1525:2007 standard, were modelled to identify the potential energy reduction and cost savings. It was found that the school's usage of electricity exceeded its need, incurring an excess expenditure of RM 2947.42. From the lighting system alone, it was found that there is a potential energy reduction of 5489.06 kWh, which gives a cost saving of RM 2282.52 via the improvement of lighting system design and its operating hours. Overall, it was found that there is a potential energy reduction and cost saving of 20.7% when the energy conservation measures are earnestly implemented. The previous energy intensity of the school was found to be 50.6 kWh/m2/year, but can theoretically be reduced to 40.19 kWh/mm2/year. PMID:25485294
Effect of Feedback and Training on Utility Usage among Adolescent Delinquents.
ERIC Educational Resources Information Center
Sexton, Richard E.; And Others
The usefulness of providing specific information and a progress/feedback mechanism to control utility usage in community-based, halfway houses for dependent-neglected and for delinquent adolescents was explored. The investigation was carried out in a random sample of 12 houses of an Arizona facility, divided into equivalent groups of three houses.…
Capacity and reliability analyses with applications to power quality
NASA Astrophysics Data System (ADS)
Azam, Mohammad; Tu, Fang; Shlapak, Yuri; Kirubarajan, Thiagalingam; Pattipati, Krishna R.; Karanam, Rajaiah
2001-07-01
The deregulation of energy markets, the ongoing advances in communication networks, the proliferation of intelligent metering and protective power devices, and the standardization of software/hardware interfaces are creating a dramatic shift in the way facilities acquire and utilize information about their power usage. The currently available power management systems gather a vast amount of information in the form of power usage, voltages, currents, and their time-dependent waveforms from a variety of devices (for example, circuit breakers, transformers, energy and power quality meters, protective relays, programmable logic controllers, motor control centers). What is lacking is an information processing and decision support infrastructure to harness this voluminous information into usable operational and management knowledge to handle the health of their equipment and power quality, minimize downtime and outages, and to optimize operations to improve productivity. This paper considers the problem of evaluating the capacity and reliability analyses of power systems with very high availability requirements (e.g., systems providing energy to data centers and communication networks with desired availability of up to 0.9999999). The real-time capacity and margin analysis helps operators to plan for additional loads and to schedule repair/replacement activities. The reliability analysis, based on computationally efficient sum of disjoint products, enables analysts to decide the optimum levels of redundancy, aids operators in prioritizing the maintenance options for a given budget and monitoring the system for capacity margin. The resulting analytical and software tool is demonstrated on a sample data center.
MEASURE: An integrated data-analysis and model identification facility
NASA Technical Reports Server (NTRS)
Singh, Jaidip; Iyer, Ravi K.
1990-01-01
The first phase of the development of MEASURE, an integrated data analysis and model identification facility is described. The facility takes system activity data as input and produces as output representative behavioral models of the system in near real time. In addition a wide range of statistical characteristics of the measured system are also available. The usage of the system is illustrated on data collected via software instrumentation of a network of SUN workstations at the University of Illinois. Initially, statistical clustering is used to identify high density regions of resource-usage in a given environment. The identified regions form the states for building a state-transition model to evaluate system and program performance in real time. The model is then solved to obtain useful parameters such as the response-time distribution and the mean waiting time in each state. A graphical interface which displays the identified models and their characteristics (with real time updates) was also developed. The results provide an understanding of the resource-usage in the system under various workload conditions. This work is targeted for a testbed of UNIX workstations with the initial phase ported to SUN workstations on the NASA, Ames Research Center Advanced Automation Testbed.
Williamson, Nicholas A
2018-03-01
This paper discusses the successful adoption of a subscription-based, open-access model of service delivery for a mass spectrometry and proteomics facility. In 2009, the Mass Spectrometry and Proteomics Facility at the University of Melbourne (Australia) moved away from the standard fee for service model of service provision. Instead, the facility adopted a subscription- or membership-based, open-access model of service delivery. For a low fixed yearly cost, users could directly operate the instrumentation but, more importantly, there were no limits on usage other than the necessity to share available instrument time with all other users. All necessary training from platform staff and many of the base reagents were also provided as part of the membership cost. These changes proved to be very successful in terms of financial outcomes for the facility, instrument access and usage, and overall research output. This article describes the systems put in place as well as the overall successes and challenges associated with the operation of a mass spectrometry/proteomics core in this manner. Graphical abstract ᅟ.
NASA Astrophysics Data System (ADS)
Williamson, Nicholas A.
2018-03-01
This paper discusses the successful adoption of a subscription-based, open-access model of service delivery for a mass spectrometry and proteomics facility. In 2009, the Mass Spectrometry and Proteomics Facility at the University of Melbourne (Australia) moved away from the standard fee for service model of service provision. Instead, the facility adopted a subscription- or membership-based, open-access model of service delivery. For a low fixed yearly cost, users could directly operate the instrumentation but, more importantly, there were no limits on usage other than the necessity to share available instrument time with all other users. All necessary training from platform staff and many of the base reagents were also provided as part of the membership cost. These changes proved to be very successful in terms of financial outcomes for the facility, instrument access and usage, and overall research output. This article describes the systems put in place as well as the overall successes and challenges associated with the operation of a mass spectrometry/proteomics core in this manner. [Figure not available: see fulltext.
How Does EIA Estimate Energy Consumption and End Uses in U.S. Homes?
2011-01-01
The Energy Information Administration (EIA) administers the Residential Energy Consumption Survey (RECS) to a nationally representative sample of housing units. Specially trained interviewers collect energy characteristics on the housing unit, usage patterns, and household demographics. This information is combined with data from energy suppliers to these homes to estimate energy costs and usage for heating, cooling, appliances and other end uses information critical to meeting future energy demand and improving efficiency and building design.
The Pollution Prevention Opportunity Assessments (PPOA) summarized here were conducted at the following representative Army Corps of Engineers (USAGE) Civil Works facilities: Pittsburgh Engineering Warehouse and Repair Station (PEWARS) and Emsworth Locks and Dams in Pittsburgh, P...
Computer Operating System Maintenance.
1982-06-01
FACILITY The Computer Management Information Facility ( CMIF ) system was developed by Rapp Systems to fulfill the need at the CRF to record and report on...computer center resource usage and utilization. The foundation of the CMIF system is a System 2000 data base (CRFMGMT) which stores and permits access
ERIC Educational Resources Information Center
Kapoor, Kanta
2010-01-01
Purpose: The purpose of this paper is to quantify the use of electronic journals in comparison with the print collections in the Guru Gobind Singh Indraprastha University Library. Design/methodology/approach: A detailed analysis was made of the use of lending services, the Xerox facility and usage of electronic journals such as Science Direct,…
NASA Technical Reports Server (NTRS)
Green, Jan
2009-01-01
This viewgraph presentation gives a detailed description of the avionics associated with the Space Shuttle's data processing system and its usage of z/OS. The contents include: 1) Mission, Products, and Customers; 2) Facility Overview; 3) Shuttle Data Processing System; 4) Languages and Compilers; 5) Application Tools; 6) Shuttle Flight Software Simulator; 7) Software Development and Build Tools; and 8) Fun Facts and Acronyms.
Learning and Teaching 24/7: Daily Internet Usage Patterns at Nine Australian Universities
ERIC Educational Resources Information Center
Spennemann, Dirk H. R.
2007-01-01
Purpose: This paper seeks to look at the usage of the internet by students, academics and university administrators as part of their normal working day. It investigates whether access to computer facilities and the mode of study have any influence, or whether other factors need to be considered when providing services. Design/methodology/approach:…
Commercial Building Tenant Energy Usage Data Aggregation and Privacy: Technical Appendix
DOE Office of Scientific and Technical Information (OSTI.GOV)
Livingston, Olga V.; Pulsipher, Trenton C.; Anderson, David M.
2014-11-12
This technical appendix accompanies report PNNL–23786 “Commercial Building Tenant Energy Usage Data Aggregation and Privacy”. The objective is to provide background information on the methods utilized in the statistical analysis of the aggregation thresholds.
[Measures to reduce lighting-related energy use and costs at hospital nursing stations].
Su, Chiu-Ching; Chen, Chen-Hui; Chen, Shu-Hwa; Ping, Tsui-Chu
2011-06-01
Hospitals have long been expected to deliver medical services in an environment that is comfortable and bright. This expectation keeps hospital energy demand stubbornly high and energy costs spiraling due to escalating utility fees. Hospitals must identify appropriate strategies to control electricity usage in order to control operating costs effectively. This paper proposes several electricity saving measures that both support government policies aimed at reducing global warming and help reduce energy consumption at the authors' hospital. The authors held educational seminars, established a website teaching energy saving methods, maximized facility and equipment use effectiveness (e.g., adjusting lamp placements, power switch and computer saving modes), posted signs promoting electricity saving, and established a regularized energy saving review mechanism. After implementation, average nursing staff energy saving knowledge had risen from 71.8% to 100% and total nursing station electricity costs fell from NT$16,456 to NT$10,208 per month, representing an effective monthly savings of 37.9% (NT$6,248). This project demonstrated the ability of a program designed to slightly modify nursing staff behavior to achieve effective and meaningful results in reducing overall electricity use.
Modern School Shop Planning. Fifth Edition.
ERIC Educational Resources Information Center
1967
Facility planning and the integration of industrial education with total school programs are discussed with regard to safety, health, budgeting, and the effects of environment upon learning and teaching. Standards for equipment selection, purchasing, and usage are given, along with equipment and supplier lists. Facility guidelines and requirements…
Energy Conservation Program Cuts School Gas Use by 45%.
ERIC Educational Resources Information Center
Sampson, Walt
1981-01-01
Energy conservation measures at Longmont High School (Colorado), including reducing air entry, heating water only during school hours, and lowering lighting levels, are expected to save 45 percent in natural gas usage and 20 percent in electric usage. (Author/MLF)
The feasibility of solar energy usage on Red River Army Depot. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Crowder, G.W.
This feasibility study considers the usage of solar energy to heat and cool the main office buildings on the Red River Army Depot, Texarkana Texas. Solar energy costs are compared with the present heating and cooling system costs with an economic analysis using the annual worth and present worth methods. (GRA)
The ICCB MIS Facility Inventory & Utilization Users Handbook.
ERIC Educational Resources Information Center
Illinois Community Coll. Board, Springfield.
This handbook is designed to assist community college administrators in using the various reports generated by the facility inventory and utilization subsystem of the Illinois Community College Board management information system. Among the reports generated by the subsystem are: room utilization report, campus classroom usage report, room use…
Energy Games - A Grade 5 Competition, The Data Analysis and Lessons Learned
NASA Astrophysics Data System (ADS)
Kao, W. H.
2016-12-01
ISF Academy, a K-G12 school in Hong Kong with over 1500 students and currently spanning 3 buildings, is retrofitting the school with an energy tracking system in three phases. The first phase that happened during February to June 2016, has included retrofitting nine Grade 5 classrooms. In this program, the daily energy usage data from these classrooms were shown. The Grade 5 students received feedback on their energy use in real time, as they competed over four months in their homeroom classes to lower their electrical use, and subsequently their carbon footprint. This competition has successfully given the 180 Grade 5 students initiative to decrease their energy use, leading to a significant decrease in energy usage throughout this competition, compared to the baseline recorded in late 2015. The winning classroom's total energy usage was around 30% lower than the average total energy usage, showing that by using energy efficiently, energy usage in a school can be decreased by a lot. The energy tracking system installed and maintained by from Global Design Corporation utilizes uniquely identified current detectors attached to circuit breakers, to monitor electrical use of individual circuits. The detectors monitor the energy used for classroom lighting, fans and plugs, as well as the air conditioners. Further analysis can also be calculated with current data that is collected in the Phase 1 experiment, such as calculating the carbon emissions reduction throughout the school year, providing possible class learning activities and also aiding in future energy use and carbon footprint predictions. This data collected will help refine phase 2 and 3 of the installation, expanding the system to more buildings and also giving insight to the rollout of the system to the whole school when the systems are fully in place. In Phase 2, the energy tracking system would be expanded to all classrooms in the old buildings, while in Phase 3, the system would be expanded the all classrooms throughout the whole campus.
Measuring the Moisture Content of Green Wood Using Time Domain Reflectometry
Laurence Schimleck; Kim Love-Myers; Joe Sanders; Heath Raybon; Richard Daniels; Jerry Mahon; Edward Andrews; Erik Schilling
2011-01-01
The responsible usage of water by facilities that rely on wet log storage in the southern United States has become an issue of great importance as restrictions on water usage have grown in recent years. In order to learn about the dynamics of moisture content in wet-stored logs over time, it is necessary to conduct continuous monitoring of log piles. Time domain...
NASA Astrophysics Data System (ADS)
Giranza, M. J.; Bergmann, A.
2018-05-01
Indonesia has abundant natural gas resources, however the primary fuel used for electricity generation is coal and oil. Insufficient natural gas infrastructure with-in the country acts as a barrier to increased natural gas usage. In Indonesia LNG is the most efficient and effective method for distributing natural gas given the difficult geographical conditions, the world’s largest archipelago and located in a deep sea area. The Government is planning to initiate natural gas imports by 2019 to meet the country’s energy demands. In order to allocate adequate amounts of natural gas across the geographic regions Indonesia must build more LNG regasification terminals. The Indonesia government has not yet determined if the additional regasification terminals will be floating or land-based facilities. This paper assesses the two options and identifies which facility attains greater profitability. The financial analysis of investing in the Sorong LNG regasification terminal project is conducted using NPV, IRR, and sensitivity analysis. This analysis demonstrates that FSRU facilities have greater economic viability than onshore LNG regasification facilities. The FSRU project earns greater than a 12% IRR as compared to a negative IRR earned by an onshore project. The government can make the onshore projects viable by increasing the sales fee from US10.00/MMBTU to US10.60/MMBTU.
Federal policy documentation and geothermal water consumption: Policy gaps and needs
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schroeder, J. N.; Harto, C. B.; Clark, C. E.
With U.S. geothermal power production expected to more than triple by 2040, and the majority of this growth expected to occur in arid and water-constrained areas, it is imperative that decision-makers understand the potential long-term limitations to and tradeoffs of geothermal development due to water availability. To this end, water consumption data, including documentation triggered by the National Environmental Policy Act (NEPA) of 1969, production and injection data, and water permit data, were collected from state and federal environmental policy sources in an effort to determine water consumption across the lifecycle of geothermal power plants. Values extracted from these sourcesmore » were analyzed to estimate water usage during well drilling; to identify sourcing of water for well drilling, well stimulation, and plant operations; and to estimate operational water usage at the plant level. Nevada data were also compared on a facility-by-facility basis with other publicly available water consumption data, to create a complete picture of water usage and consumption at these facilities. This analysis represents a unique method of capturing project-level water data for geothermal projects; however, a lack of statutory and legal requirements for such data and data quality result in significant data gaps, which are also explored« less
Methodology for the assessment of oxygen as an energy carrier
NASA Astrophysics Data System (ADS)
Yang, Ming Wei
Due to the energy intensity of the oxygen generating process, the electric power grid would benefit if the oxygen generating process was consumed electric power only during low demand periods. Thus, the question to be addressed in this study is whether oxygen production and/or usage can be modified to achieve energy storage and/or transmission objectives at lower cost. The specific benefit to grid would be a leveling, over time, of the demand profile and thus would require less installation capacity. In order to track the availability of electricity, a compressed air storage unit is installed between the cryogenic distillation section and the main air compressor of air separation unit. A profit maximizing scheme for sizing storage inventory and related equipments is developed. The optimum scheme is capable of market responsiveness. Profits of steel maker, oxy-combustion, and IGCC plants with storage facilities can be higher than those plants without storage facilities, especially, at high-price market. Price tracking feature of air storage integration will certainly increase profit margins of the plants. The integration may push oxy-combustion and integrated gasification combined cycle process into economic viability. Since oxygen is used in consumer sites, it may generate at remote locations and transport to the place needed. Energy losses and costs analysis of oxygen transportation is conducted for various applications. Energy consumptions of large capacity and long distance GOX and LOX pipelines are lower than small capacity pipelines. However, transportation losses and costs of GOX and LOX pipelines are still higher than electricity transmission.
Report on Utilities Usage and Cost, 1980-81 to 1984-85.
ERIC Educational Resources Information Center
Alabama State Commission on Higher Education, Montgomery.
The consumption and cost of energy and other types of utilities by state college campuses were analyzed by the Alabama Commission on Higher Education. A focus of attention has been changes in energy usage per square foot from year to year as an indicator of the institutions' energy conservation and, over time, of the changing characteristics of…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nester, Patrick
The rooftop Photovoltaic (PV) panels and radiant piping project was constructed by Fort Mason Center as part of its $21 million comprehensive rehabilitation of the Pier 2 shed which include the shed’s electrical, natural gas and water systems. Fort Mason Center improved performance while reducing energy and water usage and costs to demonstrate the efficiencies and opportunities available to large multi-function facilities. The scalable demand of these facilities required a layered approach to conservation, control and production. The project employed a comprehensive retrofit of electrical natural gas, and plumbing systems to maximize efficiency and lower carbon footprint specifically to demonstratemore » the effectiveness of these strategies in a public setting with varied and diverse use. The project was completed in July 2014 and met the expected outcomes regarding increased comfort and operational efficiency throughout the Pier 2 shed as well as on site electrical generation of current consumption. The entire Pier 2 shed project won a 2015 California Preservation Foundation design award for historic rehabilitation.« less
Factors motivating and affecting health information exchange usage
Zhao, Hongwei; Jaspserson, 'Jon; Gamm, Larry D; Ohsfeldt, Robert L
2011-01-01
Objective Health information exchange (HIE) is the process of electronically sharing patient-level information between providers. However, where implemented, reports indicate HIE system usage is low. The aim of this study was to determine the factors associated with different types of HIE usage. Design Cross-sectional analysis of clinical data from emergency room encounters included in an operational HIE effort linked to system user logs using crossed random-intercept logistic regression. Measurements Independent variables included factors indicative of information needs. System usage was measured as none, basic usage, or a novel pattern of usage. Results The system was accessed for 2.3% of all encounters (6142 out of 271 305). Novel usage patterns were more likely for more complex patients. The odds of HIE usage were lower in the face of time constraints. In contrast to expectations, system usage was lower when the patient was unfamiliar to the facility. Limitations Because of differences between HIE efforts and the fact that not all types of HIE usage (ie, public health) could be included in the analysis, results are limited in terms of generalizablity. Conclusions This study of actual HIE system usage identifies patients and circumstances in which HIE is more likely to be used and factors that are likely to discourage usage. The paper explores the implications of the findings for system redesign, information integration across exchange partners, and for meaningful usage criteria emerging from provisions of the Health Information Technology for Economic & Clinical Health Act. PMID:21262919
Systems and methods for controlling energy use in a building management system using energy budgets
Wenzel, Michael J.
2012-06-17
Systems and methods for limiting power consumption by a heating, ventilation, and air conditioning (HVAC) subsystem of a building are shown and described. A mathematical linear operator is found that transforms the unused or deferred cooling power usage of the HVAC system based on pre-determined temperature settings to a target cooling power usage. The mathematical operator is applied to the temperature settings to create a temperature setpoint trajectory expected to provide the target cooling power usage.
Energy Conservation: Implementing an Effective Campus Program.
ERIC Educational Resources Information Center
Marsee, Jeff
After reviewing the physical plant environment and temperature control equipment at Eastfield College (Texas), this paper explains how redirected efforts toward energy conservation can result in important cost/usage savings. Electricity billing rates are explained to provide a stronger usage strategy for cost effectiveness. Two methods of reducing…
Performance and Usage of Biometrics in a Testbed Environment for Tactical Purposes
2006-12-01
19 c. Facial Recognition ..................................................................20...geometry, iris recognition, and facial recognition (Layman’s, 2005). Behavioral biometrics can be described not as a physical characteristic, but are...are at: • Correction facilities • Department of Motor Vehicle • Military checkpoints • POW facilities c. Facial Recognition Facial recognition is
NASA Astrophysics Data System (ADS)
Khroustalev, V. A.; Simonyan, A. A.
2017-11-01
There was carried out an analysis of technical characteristics of boiler houses in a number of Russian NPPs. We justified the possibility of their usage for autonomous generation of electrical energy and improvement of maneuvering properties of power complexes as a single object of regulation, as well as the possibility of increasing the total generation capacity of NPP power units during peak hours. Then the selection of the main equipment of house boiler for its autonomous work was done. There were composed basic thermal diagrams of the power complex on the basis of NPP start-up boiler (SUB) and the satellite turbine. The article also considers some options of reconstruction of SUB into the heat-recovery boiler. The developed power complexes are designed to be used on the basis of the two-loop NPP with pressurized power reactors (PWR). They can be applied with serial and projected domestic NPP units with the aim of getting more power, improving the plant capacity factor (PCF), as well as with the aim of NPP participation in the regulation of the load curve above the nominal value with partial replacement of new construction. The power complexes can be a relevant solution in the light of the energy strategy of the Russian Federation, which is aimed at, firstly, further improvement of efficiency and safety at the NPP, and, secondly, solving the problem of adequate maneuverability and ensuring the adjustment range limits in power systems with high share of nuclear power plants. Implementation of new hybrid thermal diagrams allows simultaneous increase in the safety of NPP, and usage of nuclear power plants emergency frequency control in power systems by fast load drop and rise by -4÷+2 % of the nominal value. Due to the usage of different fuels in power complexes, uranium loading in the core of reactor facilities and gas in SUB, there was proposed and formalized the criterion of “thermoeconomic index”. This criterion represents the ratio of the gross receipt from the sale of electricity to the total cost of fuel of all kinds, spent on ensuring power efficiency.
Energy profiles of four American states
NASA Astrophysics Data System (ADS)
Song, Jiamei
2018-06-01
Energy production and usage are the major portion of any economy. With the constant consumption of the polluting energy and the deteriorating environment, people are paying more and more attention to clean, renewable energy. Based on autoregressive model and TOPSIS, though analyzing the past data, this paper establishes the energy profiles of four American states from 1960 to 2009, predict the energy profiles for 2025 and 2050 and obtain the ideal criteria for future clean, renewable energy usage at last. This study finds that by analyzing and predicting the energy profile, human beings can better understand and grasp the trend of energy development and take appropriate measures to deal with future energy trends.
Salahuddin, Mohammad; Alam, Khorshed; Ozturk, Ilhan
2016-03-01
This study estimates the short- and long-run effects of Internet usage and economic growth on carbon dioxide (CO2) emissions using annual time series macro data for Australia for the period 1985-2012. Autoregressive distributive lag (ARDL) bounds and Gregory-Hansen structural break cointegration tests are applied. ARDL estimates indicate no significant long-run relationship between Internet usage and CO2 emissions, which implies that the rapid growth in Internet usage is still not an environmental threat for Australia. The study further indicates that higher level of economic growth is associated with lower level of CO2 emissions; however, Internet usage and economic growth have no significant short-run relationship with CO2 emissions. Financial development has both short-run and long-run significant positive association with CO2 emissions. The findings offer support in favor of energy efficiency gains and a reduction in energy intensity in Australia. However, impulse response and variance decomposition analysis suggest that Internet usage, economic growth and financial development will continue to impact CO2 emissions in the future, and as such, this study recommends that in addition to the existing measures to combat CO2 emissions, Australia needs to exploit the potential of the Internet not only to reduce its own carbon footprint but also to utilize information and communication technology (ICT)-enabled emissions abatement potential to reduce emissions in various other sectors across the economy, such as, power, renewable energy especially in solar and wind energy, agriculture, transport and service.
Fournier, Eric D; Keller, Arturo A; Geyer, Roland; Frew, James
2016-02-16
This project investigates the energy-water usage efficiency of large scale civil infrastructure projects involving the artificial recharge of subsurface groundwater aquifers via the reuse of treated municipal wastewater. A modeling framework is introduced which explores the various ways in which spatially heterogeneous variables such as topography, landuse, and subsurface infiltration capacity combine to determine the physical layout of proposed reuse system components and their associated process energy-water demands. This framework is applied to the planning and evaluation of the energy-water usage efficiency of hypothetical reuse systems in five case study regions within the State of California. Findings from these case study analyses suggest that, in certain geographic contexts, the water requirements attributable to the process energy consumption of a reuse system can exceed the volume of water that it is able to recover by as much as an order of magnitude.
Monitoring Object Library Usage and Changes
NASA Technical Reports Server (NTRS)
Owen, R. K.; Craw, James M. (Technical Monitor)
1995-01-01
The NASA Ames Numerical Aerodynamic Simulation program Aeronautics Consolidated Supercomputing Facility (NAS/ACSF) supercomputing center services over 1600 users, and has numerous analysts with root access. Several tools have been developed to monitor object library usage and changes. Some of the tools do "noninvasive" monitoring and other tools implement run-time logging even for object-only libraries. The run-time logging identifies who, when, and what is being used. The benefits are that real usage can be measured, unused libraries can be discontinued, training and optimization efforts can be focused at those numerical methods that are actually used. An overview of the tools will be given and the results will be discussed.
ERIC Educational Resources Information Center
Beaulieu, Barbara; And Others
This unit of instruction on home energy usage and conservation was designed for use by home economics teachers in Florida high schools and by home economics extension agents as they work with their clientele. It is one of a series of 11 instructional units (see note) written to help teachers and agents to educate their students and clients about…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gordon, A.; Lubliner, M.; Howard, L.
2014-04-01
This project analyzes the cost effectiveness of energy savings measures installed by a large public housing authority in Salishan, a community in Tacoma Washington. Research focuses on the modeled and measured energy usage of the first six phases of construction, and compares the energy usage of those phases to phase 7. Market-ready energy solutions were also evaluated to improve the efficiency of affordable housing for new and existing (built since 2001) affordable housing in the marine climate of Washington State.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
2014-03-01
This project analyzes the cost effectiveness of energy savings measures installed by a large public housing authority in Salishan, a community in Tacoma Washington. Research focuses on the modeled and measured energy usage of the first six phases of construction, and compares the energy usage of those phases to phase 7. Market-ready energy solutions were also evaluated to improve the efficiency of affordable housing for new and existing (built since 2001) affordable housing in the marine climate of Washington State.
Saving Water at Los Alamos National Laboratory
DOE Office of Scientific and Technical Information (OSTI.GOV)
Erickson, Andy
Los Alamos National Laboratory decreased its water usage by 26 percent in 2014, with about one-third of the reduction attributable to using reclaimed water to cool a supercomputing center. The Laboratory's goal during 2014 was to use only re-purposed water to support the mission at the Strategic Computing Complex. Using reclaimed water from the Sanitary Effluent Reclamation Facility, or SERF, substantially decreased water usage and supported the overall mission. SERF collects industrial wastewater and treats it for reuse. The reclamation facility contributed more than 27 million gallons of re-purposed water to the Laboratory's computing center, a secured supercomputing facility thatmore » supports the Laboratory’s national security mission and is one of the institution’s larger water users. In addition to the strategic water reuse program at SERF, the Laboratory reduced water use in 2014 by focusing conservation efforts on areas that use the most water, upgrading to water-conserving fixtures, and repairing leaks identified in a biennial survey.« less
Saving Water at Los Alamos National Laboratory
Erickson, Andy
2018-01-16
Los Alamos National Laboratory decreased its water usage by 26 percent in 2014, with about one-third of the reduction attributable to using reclaimed water to cool a supercomputing center. The Laboratory's goal during 2014 was to use only re-purposed water to support the mission at the Strategic Computing Complex. Using reclaimed water from the Sanitary Effluent Reclamation Facility, or SERF, substantially decreased water usage and supported the overall mission. SERF collects industrial wastewater and treats it for reuse. The reclamation facility contributed more than 27 million gallons of re-purposed water to the Laboratory's computing center, a secured supercomputing facility that supports the Laboratoryâs national security mission and is one of the institutionâs larger water users. In addition to the strategic water reuse program at SERF, the Laboratory reduced water use in 2014 by focusing conservation efforts on areas that use the most water, upgrading to water-conserving fixtures, and repairing leaks identified in a biennial survey.
Tracing Scientific Facilities through the Research Literature Using Persistent Identifiers
NASA Astrophysics Data System (ADS)
Mayernik, M. S.; Maull, K. E.
2016-12-01
Tracing persistent identifiers to their source publications is an easy task when authors use them, since it is a simple matter of matching the persistent identifier to the specific text string of the identifier. However, trying to understand if a publication uses the resource behind an identifier when such identifier is not referenced explicitly is a harder task. In this research, we explore the effectiveness of alternative strategies of associating publications with uses of the resource referenced by an identifier when it may not be explicit. This project is explored within the context of the NCAR supercomputer, where we are broadly interesting in the science that can be traced to the usage of the NCAR supercomputing facility, by way of the peer-reviewed research publications that utilize and reference it. In this project we explore several ways of drawing linkages between publications and the NCAR supercomputing resources. Identifying and compiling peer-reviewed publications related to NCAR supercomputer usage are explored via three sources: 1) User-supplied publications gathered through a community survey, 2) publications that were identified via manual searching of the Google scholar search index, and 3) publications associated with National Science Foundation (NSF) grants extracted from a public NSF database. These three sources represent three styles of collecting information about publications that likely imply usage of the NCAR supercomputing facilities. Each source has strengths and weaknesses, thus our discussion will explore how our publication identification and analysis methods vary in terms of accuracy, reliability, and effort. We will also discuss strategies for enabling more efficient tracing of research impacts of supercomputing facilities going forward through the assignment of a persistent web identifier to the NCAR supercomputer. While this solution has potential to greatly enhance our ability to trace the use of the facility through publications, authors must cite the facility consistently. It is therefore necessary to provide recommendations for citation and attribution behavior, and we will conclude our discussion with how such recommendations have improved tracing the supercomputer facility allowing for more consistent and widespread measurement of its impact.
Building Climate Resilience at NASA Ames Research Center
NASA Astrophysics Data System (ADS)
Iraci, L. T.; Mueller, C.; Podolske, J. R.; Milesi, C.
2016-12-01
NASA Ames Research Center, located at the southern end of the San Francisco Bay (SFB) estuary, has identified three primary vulnerabilities to changes in climate. The Ames Climate Adaptation Science Investigator (CASI) workgroup has studied each of these challenges to operations and the potential exposure of infrastructure and employees to an increased frequency of hazards. Sea level rise inundation scenarios for the SFB Area generally refer to projected scenarios in mean sea level rather than changes in extreme tides that could occur during future storm conditions. In the summer of 2014, high resolution 3-D mapping of the low-lying portion of Ames was performed. Those data are integrated with improved sea level inundation scenarios to identify the buildings, basements and drainage systems potentially affected. We will also identify the impacts of sea level and storm surge effects on transportation to and from the Center. This information will help Center management develop future master plans. Climate change will also lead to changes in temperature, storm frequency and intensity. These changes have potential impacts on localized floods and ecosystems, as well as on electricity and water availability. Over the coming decades, these changes will be imposed on top of ongoing land use and land cover changes, especially those deriving from continued urbanization and increase in impervious surface areas. These coupled changes have the potential to create a series of cascading impacts on ecosystems, including changes in primary productivity and disturbance of hydrological properties and increased flood risk. The majority of the electricity used at Ames is supplied by hydroelectric dams, which will be influenced by reductions in precipitation or changes in the timing or phase of precipitation which reduces snow pack. Coupled with increased demand for summertime air conditioning and other cooling needs, NASA Ames is at risk for electricity shortfalls. To assess the anticipated energy usage as climate changes, the Ames CASI team is collecting historical energy usage data from Ames facilities, historical weather data, and projected future weather parameters from the CASI Climate subgroup. This data will be incorporated into the RETScreen model to predict how energy usage at Ames will change over the coming century.
Commercial and Multifamily Building Tenant Energy Usage Aggregation and Privacy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Livingston, Olga V.; Pulsipher, Trenton C.; Wang, Na
2014-11-17
In a number of cities and states, building owners are required to disclose and/or benchmark their building energy use. This requires the building owner to possess monthly whole-building energy usage information, which can be challenging for buildings in which individual tenants have their own utility meters and accounts with the utility. Some utilities and utility regulators have turned to aggregation of customer data as a way to give building owners the whole-building energy usage data while protecting customer privacy. However, no utilities or regulators appear to have conducted a concerted statistical, cybersecurity, and privacy analysis to justify the level ofmore » aggregation selected. Therefore, the Tennant Data Aggregation Task was established to help utilities address these issues and provide recommendations as well as a theoretical justification of the aggregation threshold. This study is focused on the use case of submitting data for ENERGY STAR Portfolio Manager (ESPM), but it also looks at other potential use cases for monthly energy consumption data.« less
Physician self-referral and physician-owned specialty facilities.
Casalino, Lawrence P
2008-06-01
Physician self-referral ranges from suggesting a follow-up appointment, to sending a patient to a facility in which the doctor has an ownership interest or financial relationship. Physician referral to facilities in which the physicians have an ownership interest is becoming increasingly common and not always medically appropriate. This Synthesis reviews the evidence on physician self-referral arrangements, their effect on costs and utilization, and their effect on general hospitals. Key findings include: the rise in self-referral is sparked by financial, regulatory and clinical incentives, including patient convenience and doctors trying to preserve their income in the changing health care landscape. Strong evidence suggests self-referral leads to increased usage of health care services; but there is insufficient evidence to determine whether this increased usage reflects doctors meeting an unmet need or ordering clinically inappropriate care. The more significant a physician's financial interest in a facility, the more likely the doctor is to refer patients there. Arrangements through which doctors receive fees for patient referrals to third-party centers, such as "pay-per-click," time-share, and leasing arrangements, do not seem to offer benefits beyond increasing physician income. So far, the profit margins of general hospitals have not been harmed by the rise in doctor-owned facilities.
Implications of driving patterns on well-to-wheel performance of plug-in hybrid electric vehicles.
Raykin, Leon; MacLean, Heather L; Roorda, Matthew J
2012-06-05
This study examines how driving patterns (distance and conditions) and the electricity generation supply interact to impact well-to-wheel (WTW) energy use and greenhouse gas (GHG) emissions of plug-in hybrid electric vehicles (PHEVs). The WTW performance of a PHEV is compared with that of a similar (nonplug-in) gasoline hybrid electric vehicle and internal combustion engine vehicle (ICEV). Driving PHEVs for short distances between recharging generally results in lower WTW total and fossil energy use and GHG emissions per kilometer compared to driving long distances, but the extent of the reductions depends on the electricity supply. For example, the shortest driving pattern in this study with hydroelectricity uses 81% less fossil energy than the longest driving pattern. However, the shortest driving pattern with coal-based electricity uses only 28% less fossil energy. Similar trends are observed in reductions relative to the nonplug-in vehicles. Irrespective of the electricity supply, PHEVs result in greater reductions in WTW energy use and GHG emissions relative to ICEVs for city than highway driving conditions. PHEVs charging from coal facilities only reduce WTW energy use and GHG emissions relative to ICEVs for certain favorable driving conditions. The study results have implications for environmentally beneficial PHEV adoption and usage patterns.
7 CFR 500.22 - Fees and conditions for use of facilities and grounds.
Code of Federal Regulations, 2013 CFR
2013-01-01
... is committed, including time used to set up before and clean up after an event. For after-hours usage of sites or facilities, an additional $40/hour will be added for supervision for each required staff... the planned use or event. (4) A 50 percent non-refundable deposit will be due at the time of a booking...
7 CFR 500.22 - Fees and conditions for use of facilities and grounds.
Code of Federal Regulations, 2014 CFR
2014-01-01
... is committed, including time used to set up before and clean up after an event. For after-hours usage of sites or facilities, an additional $40/hour will be added for supervision for each required staff... the planned use or event. (4) A 50 percent non-refundable deposit will be due at the time of a booking...
7 CFR 500.22 - Fees and conditions for use of facilities and grounds.
Code of Federal Regulations, 2011 CFR
2011-01-01
... is committed, including time used to set up before and clean up after an event. For after-hours usage of sites or facilities, an additional $40/hour will be added for supervision for each required staff... the planned use or event. (4) A 50 percent non-refundable deposit will be due at the time of a booking...
7 CFR 500.22 - Fees and conditions for use of facilities and grounds.
Code of Federal Regulations, 2012 CFR
2012-01-01
... is committed, including time used to set up before and clean up after an event. For after-hours usage of sites or facilities, an additional $40/hour will be added for supervision for each required staff... the planned use or event. (4) A 50 percent non-refundable deposit will be due at the time of a booking...
Changes in Psychotropic Drug Use in Long-Term Residents of an ICF/MR Facility.
ERIC Educational Resources Information Center
Hancock, Robert D.; And Others
1991-01-01
Psychotropic drug use was monitored for 139 persons residing continuously over a 10-year period in an Intermediate Care Facility for mentally retarded persons. Results indicated an ongoing decrease in psychotropic drug use, with usage decreasing from 30-12 percent. Antipsychotic medication was discontinued for 73 percent of the clients over the 10…
Potential reduction of energy consumption in public university library
NASA Astrophysics Data System (ADS)
Noranai, Z.; Azman, ADF
2017-09-01
Efficient electrical energy usage has been recognized as one of the important factor to reduce cost of electrical energy consumption. Various parties have been emphasized about the importance of using electrical energy efficiently. Inefficient usage of electrical energy usage lead to biggest factor increasing of administration cost in Universiti Tun Hussein Onn Malaysia. With this in view, a project the investigate potential reduction electrical energy consumption in Universiti Tun Hussein Onn Malaysia was carried out. In this project, a case study involving electrical energy consumption of Perpustakaan Tunku Tun Aminah was conducted. The scopes of this project are to identify energy consumption in selected building and to find the factors that contributing to wastage of electrical energy. The MS1525:2001, Malaysian Standard - Code of practice on energy efficiency and use of renewable energy for non-residential buildings was used as reference. From the result, 4 saving measure had been proposed which is change type of the lamp, install sensor, decrease the number of lamp and improve shading coefficient on glass. This saving measure is suggested to improve the efficiency of electrical energy consumption. Improve of human behaviour toward saving energy measure can reduce 10% from the total of saving cost while on building technical measure can reduce 90% from total saving cost.
An overview of the energy situation
NASA Technical Reports Server (NTRS)
Pitts, D. R.
1978-01-01
Beginning with a historical review of the domestic pattern of energy usage, the current dependence of the United States upon dwindling petroleum resources is examined. The possible limit of petroleum usage is discussed, and recent oil production trends are presented. Coupling these with projected analyses of OPEC oil productive capability in the early 1980's indicates a serious worldwide as well as American energy problem in the next decade. The need for conservation and rapid development of application of alternative energy resources is discussed including quantitative projections of significant conservation efforts as well as estimates of domestic alternative energy resource capabilities.
Water Management Planning: A Case Study at Blue Grass Army Depot
DOE Office of Scientific and Technical Information (OSTI.GOV)
Solana, Amy E.; Mcmordie, Katherine
2006-04-03
Executive Order 13123, Greening the Government Through Efficient Energy Management, mandates an aggressive policy for reducing potable water consumption at federal facilities. Implementation guid¬ance from the U.S. Department of Energy (DOE) set a requirement for each federal agency to “reduce potable water usage by implementing life cycle, cost-effective water efficiency programs that include a water management plan, and not less than four Federal Energy Management Program (FEMP) Best Manage¬ment Practices (BMPs).” The objective of this plan is to gain full compliance with Executive Order 13123 and associated DOE implementation guidance on behalf of Blue Grass Army Depot (BGAD), Richmond, Kentucky.more » In accordance with this plan, BGAD must: • Incorporate the plan as a component of the Installation energy conservation plan • Investigate the water savings potential and life-cycle cost effectiveness of the Operations and Maintenance (O&M) and retrofit/replacement options associated with the ten FEMP BMPs • Put into practice all applicable O&M options • Identify retrofit/replacement options appropriate for implementation (based upon calculation of the simple payback periods) • Establish a schedule for implementation of applicable and cost-effective retrofit/replacement options.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bodnaruk, W.H. Jr.
1983-04-01
The aim of this study was to develop and demonstrate low energy climate control and production techniques for greenhouse grown citrus and ornamental crops. Emphasis was placed on design, fuel efficiency and plant response to warm water soil heating systems using solar energy and LP gas. An energy requirement of 28Btus output per hour per square foot of bed space will provide soil temperature of 70/sup 0/F minimum when air temperatures are maintained at 60/sup 0/F. Soil heating to 70/sup 0/ increased rooting and growth of 8 foliage plant varieties by 25 to 45% compared to plants grown under 60/supmore » 0/F air temperature conditions. Providing soil heating, however, increased fuel consumption in the central Florida test facilities by 30% in the winters of 1980-81 and 1981-82. Solar tie-in to soil heating systems has the potential of reducing fuel usage. Solar heated water provided 4 hours of soil heating following a good collection day. Decreased in-bed pipe spacing and increased storage capacity should increase the solar percentage to 6 hours.« less
Usage of energy reserves in crustaceans during starvation: status and future directions.
Sánchez-Paz, Arturo; García-Carreño, Fernando; Muhlia-Almazán, Adriana; Peregrino-Uriarte, Alma B; Hernández-López, Jorge; Yepiz-Plascencia, Gloria
2006-04-01
In this paper, we review the current knowledge about the usage of carbohydrates, lipids and proteins as energy source by marine crustaceans during starvation. Crustaceans are a large and diverse group including some economically important species. The efforts to culture them for human consumption has prompted the interest to understand the preferences of energy sources to be applied for feed formulation and cost reduction. Important differences have been found among species and appear to be related not only to the biochemistry and physiology of nutrition, but also to the living environment of the crustaceans. Furthermore, crustaceans undergo morphological, physiological and behavioral changes due to their natural growing process that affect their feeding habits, an aspect that should be carefully considered. We discuss the current information on marine crustaceans about energy usage and describe areas of future research, where starvation studies render important insights.
Lenk, Fabian; Bröring, Stefanie; Herzog, Philipp; Leker, Jens
2007-12-01
Bioenergies are promoted across the globe as the answer for global warming and the chance to reduce dependency from fossil energy sources. Despite the fact that renewable energy sources offer the opportunity to reduce CO2 emission and present a chance to increase agricultural incomes, they also come along with some drawbacks that have been mostly neglected in the current discussion. This paper seeks to build a basis for discussing the impacts of the growing subsidization of bioenergy and the resulting usage competition of agricultural raw materials between foods and energy. To assess the usage competition and the subsidization of bioenergy, this article employs a welfare economics perspective associated with an emphasize on the construct of externalities. This will help to foster the discussion on the further subsidization of bioenergy, where funding for R&D on new ways of using non-food raw materials ought to play a significant role.
NASA Astrophysics Data System (ADS)
Silva, Humberto; Fillpot, Baron S.
2018-01-01
A reduction in both power and electricity usage was determined using a previously validated zero-dimensional energy balance model that implements mitigation strategies used to reduce the urban heat island (UHI) effect. The established model has been applied to show the change in urban characteristic temperature when executing four common mitigation strategies: increasing the overall (1) emissivity, (2) vegetated area, (3) thermal conductivity, and (4) albedo of the urban environment in a series of increases by 5, 10, 15, and 20% from baseline values. Separately, a correlation analysis was performed involving meteorological data and total daily energy (TDE) consumption where the 24-h average temperature was shown to have the greatest correlation to electricity service data in the Phoenix, Arizona, USA, metropolitan region. A methodology was then developed for using the model to predict TDE consumption reduction and corresponding cost-saving analysis when implementing the four mitigation strategies. The four modeled UHI mitigation strategies, taken in combination, would lead to the largest percent reduction in annual energy usage, where increasing the thermal conductivity is the single most effective mitigation strategy. The single least effective mitigation strategy, increasing the emissivity by 5% from the baseline value, resulted in an average calculated reduction of about 1570 GWh in yearly energy usage with a corresponding 157 million dollar cost savings. When the four parameters were increased in unison by 20% from baseline values, an average calculated reduction of about 2050 GWh in yearly energy usage was predicted with a corresponding 205 million dollar cost savings.
General specifications for the development of a PC-based simulator of the NASA RECON system
NASA Technical Reports Server (NTRS)
Dominick, Wayne D. (Editor); Triantafyllopoulos, Spiros
1984-01-01
The general specifications for the design and implementation of an IBM PC/XT-based simulator of the NASA RECON system, including record designs, file structure designs, command language analysis, program design issues, error recovery considerations, and usage monitoring facilities are discussed. Once implemented, such a simulator will be utilized to evaluate the effectiveness of simulated information system access in addition to actual system usage as part of the total educational programs being developed within the NASA contract.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Todd, A.; Perry, M.; Smith, B.
2015-04-01
Smart meters, smart thermostats, and other new technologies provide previously unavailable high-frequency and location-specific energy usage data. Many utilities are now able to capture real-time, customer-specific hourly interval usage data for a large proportion of their residential and small commercial customers. These vast, constantly growing streams of rich data (or big data) have the potential to provide novel insights into key policy questions about how people make energy decisions.
42 CFR 59.5 - What requirements must be met by a family planning project?
Code of Federal Regulations, 2012 CFR
2012-10-01
... examination, contraceptive supplies) and necessary referral to other medical facilities when medically indicated, and provide for the effective usage of contraceptive devices and practices. (2) Provide for...
42 CFR 59.5 - What requirements must be met by a family planning project?
Code of Federal Regulations, 2011 CFR
2011-10-01
... examination, contraceptive supplies) and necessary referral to other medical facilities when medically indicated, and provide for the effective usage of contraceptive devices and practices. (2) Provide for...
42 CFR 59.5 - What requirements must be met by a family planning project?
Code of Federal Regulations, 2013 CFR
2013-10-01
... examination, contraceptive supplies) and necessary referral to other medical facilities when medically indicated, and provide for the effective usage of contraceptive devices and practices. (2) Provide for...
42 CFR 59.5 - What requirements must be met by a family planning project?
Code of Federal Regulations, 2014 CFR
2014-10-01
... examination, contraceptive supplies) and necessary referral to other medical facilities when medically indicated, and provide for the effective usage of contraceptive devices and practices. (2) Provide for...
ERIC Educational Resources Information Center
Ruggerini, Ciro; Guaraldi, Gian Paolo; Russo, Angela; Neviani, Vittoria; Castagnini, Augusto
2004-01-01
Since the implementation of a psychiatric service in a long-term facility for people with intellectual disability, the usage of psychotropic and anti-convulsant drugs has been surveyed over the 5-year period 1994-1999. At that time, although the overall prevalence rate of residents on medication was not declining significantly, a decrease in…
Challenges in scaling NLO generators to leadership computers
NASA Astrophysics Data System (ADS)
Benjamin, D.; Childers, JT; Hoeche, S.; LeCompte, T.; Uram, T.
2017-10-01
Exascale computing resources are roughly a decade away and will be capable of 100 times more computing than current supercomputers. In the last year, Energy Frontier experiments crossed a milestone of 100 million core-hours used at the Argonne Leadership Computing Facility, Oak Ridge Leadership Computing Facility, and NERSC. The Fortran-based leading-order parton generator called Alpgen was successfully scaled to millions of threads to achieve this level of usage on Mira. Sherpa and MadGraph are next-to-leading order generators used heavily by LHC experiments for simulation. Integration times for high-multiplicity or rare processes can take a week or more on standard Grid machines, even using all 16-cores. We will describe our ongoing work to scale the Sherpa generator to thousands of threads on leadership-class machines and reduce run-times to less than a day. This work allows the experiments to leverage large-scale parallel supercomputers for event generation today, freeing tens of millions of grid hours for other work, and paving the way for future applications (simulation, reconstruction) on these and future supercomputers.
Burden of emergency conditions and emergency care usage: new estimates from 40 countries.
Chang, Cindy Y; Abujaber, Samer; Reynolds, Teri A; Camargo, Carlos A; Obermeyer, Ziad
2016-11-01
To estimate the global and national burden of emergency conditions, and compare them to emergency care usage rates. We coded all 291 Global Burden of Disease 2010 conditions into three categories to estimate emergency burden: conditions that, if not addressed within hours to days of onset, commonly lead to serious disability or death; conditions with common acute decompensations that lead to serious disability or death; and non-emergencies. Emergency care usage rates were obtained from a systematic literature review on emergency care facilities in low-income and middle-income countries (LMICs), supplemented by national health system reports. All 15 leading causes of death and disability-adjusted life years (DALYs) globally were conditions with potential emergent manifestations. We identified 41 facility-based reports in 23 countries, 12 of which were in LMICs; data for 17 additional countries were obtained from national or regional reports on emergency usage. Burden of emergency conditions was the highest in low-income countries, with median DALYs of 47 728 per 100 000 population (IQR 45 253-50 085) in low-income, 25 186 (IQR 21 982-40 480) in middle-income and 15 691 (IQR 14 649-16 382) in high-income countries. Patterns were similar using deaths to measure burden and excluding acute decompensations from the definition of emergency conditions. Conversely, emergency usage rates were the lowest in low-income countries, with median 8 visits per 1000 population (IQR 6-10), 78 (IQR 25-197) in middle-income and 264 (IQR 177-341) in high-income countries. Despite higher burden of emergency conditions, emergency usage rates are substantially lower in LMICs, likely due to limited access to emergency care. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Ballard, Clive; Powell, Ian; James, Ian; Reichelt, Katharina; Myint, Pat; Potkins, Dawn; Bannister, Carol; Lana, Marisa; Howard, Robert; O'Brien, John; Swann, Alan; Robinson, Damian; Shrimanker, Jay; Barber, Robert
2002-02-01
The quality of care and overuse of neuroleptic medication in care environments are major issues in the care of elderly people with dementia. The quality of care (Dementia Care Mapping), the severity of Behavioural and Psychological Symptoms (BPSD--Neuropsychiatric Inventory), expressive language skills (Sheffield Acquired Language Disorder scale), service utilization and use of neuroleptic drugs was compared over 9 months between six care facilities receiving a psychiatric liaison service and three facilities receiving the usual clinical support, using a single blind design. There was a significant reduction in neuroleptic usage in the facilities receiving the liaison service (McNemar test p<0.0001), but not amongst those receiving standard clinical support (McNemar test p=0.07). There were also significantly less GP contacts (t=3.9 p=0.0001) for residents in the facilities receiving the liaison service, and a three fold reduction in psychiatric in-patient bed usage (Bed days per person 0.6 vs. 1.5). Residents in care facilities receiving the liaison service experienced significantly less deterioration in expressive language skills (t=2.2 p=0.03), but there were no significant differences in BPSD or wellbeing. A resource efficient psychiatric liaison service can reduce neuroleptic drug use and reduce some aspects of health service utilization; but a more extensive intervention is probably required to improve the overall quality of care. Copyright 2002 John Wiley & Sons, Ltd.
Chou, Ann F; Graber, Christopher J; Jones, Makoto; Zhang, Yue; Goetz, Matthew Bidwell; Madaras-Kelly, Karl; Samore, Matthew; Kelly, Allison; Glassman, Peter A
2016-06-01
BACKGROUND Antimicrobial stewardship programs (ASPs) are variably implemented. OBJECTIVE To characterize variations of antimicrobial stewardship structure and practices across all inpatient Veterans Affairs facilities in 2012 and correlate key characteristics with antimicrobial usage. DESIGN A web-based survey regarding stewardship activities was administered to each facility's designated contact. Bivariate associations between facility characteristics and inpatient antimicrobial use during 2012 were determined. SETTING Total of 130 Veterans Affairs facilities with inpatient services. RESULTS Of 130 responding facilities, 29 (22%) had a formal policy establishing an ASP, and 12 (9%) had an approved ASP business plan. Antimicrobial stewardship teams were present in 49 facilities (38%); 34 teams included a clinical pharmacist with formal infectious diseases (ID) training. Stewardship activities varied across facilities, including development of yearly antibiograms (122 [94%]), formulary restrictions (120 [92%]), stop orders for antimicrobial duration (98 [75%]), and written clinical pathways for specific conditions (96 [74%]). Decreased antimicrobial usage was associated with having at least 1 full-time ID physician (P=.03), an ID fellowship program (P=.003), and a clinical pharmacist with formal ID training (P=.006) as well as frequency of systematic patient-level reviews of antimicrobial use (P=.01) and having a policy to address antimicrobial use in the context of Clostridium difficile infection (P=.01). Stop orders for antimicrobial duration were associated with increased use (P=.03). CONCLUSIONS ASP-related activities varied considerably. Decreased antibiotic use appeared related to ID presence and certain select practices. Further statistical assessments may help optimize antimicrobial practices. Infect Control Hosp Epidemiol 2016;37:647-654.
Nazi, Kim M; Hibbard, Judith H; Houston, Thomas K
2017-01-01
Background As electronic health records and computerized workflows expand, there are unprecedented opportunities to digitally connect with patients using secure portals. To realize the value of patient portals, initial reach across populations will need to be demonstrated, as well as sustained usage over time. Objective The study aim was to identify patient factors associated with short-term and long-term portal usage after patients registered to access all portal functions. Methods We prospectively followed a cohort of patients at a large Department of Veterans Affairs (VA) health care facility who recently completed identity proofing to use the VA patient portal. Information collected at baseline encompassed patient factors potentially associated with portal usage, including: demographics, Internet access and use, health literacy, patient activation, and self-reported health conditions. The primary outcome was the frequency of portal log-ins during 6-month and 18-month time intervals after study enrollment. Results A total of 270 study participants were followed prospectively. Almost all participants (260/268, 97.0%) reported going online, typically at home (248/268, 92.5%). At 6 months, 84.1% (227/270) of participants had visited the portal, with some variation in usage across demographic and health-related subgroups. There were no significant differences in portal log-ins by age, gender, education, marital status, race/ethnicity, distance to a VA facility, or patient activation measure. Significantly higher portal usage was seen among participants using high-speed broadband at home, greater self-reported ability using the Internet, and routinely going online. By 18 months, 91% participants had logged in to the portal, and no significant associations were found between usage and demographics, health status, or patient activation. When examining portal activity between 6 and 18 months, patients who were infrequent or high portal users remained in those categories, respectively. Conclusions Short-term and long-term portal usage was associated with having broadband at home, high self-rated ability when using the Internet, and overall online behavior. Digital inclusion, or ready access to the Internet and digital skills, appears to be a social determinant in patient exposure to portal services. PMID:29042345
A survey on human behavior towards energy efficiency for office worker in malaysia
NASA Astrophysics Data System (ADS)
Mustafa, N. H.; Husain, M. N.; Abd Aziz, M. Z. A.; Othman, M. A.; Malek, F.
2014-04-01
Green environment has become an important topic around the world. This campaign can be realized if everybody understands and shares similar objectives on managing energy in an efficient way. This paper will present and analyse the survey on energy usage by office workers in Malaysia. The survey will focus on the workers in government sector. In social science surveys, it is important to support the tested data for a project. For issues related to human behaviour we must compare with real situations to verify the tested data and the results in energy monitoring system. The energy monitoring system will improve energy usage efficiency for the basic human activities in different situations and environments.
Utilization of prostate brachytherapy for low risk prostate cancer: Is the decline overstated?
Safdieh, Joseph; Wong, Andrew; Weiner, Joseph P; Schwartz, David; Schreiber, David
2016-08-01
Several prior studies have suggested that brachytherapy utilization has markedly decreased, coinciding with the recent increased utilization of intensity modulated radiation therapy, as well as an increase in urologist-owned centers. We sought to investigate the brachytherapy utilization in a large, hospital-based registry. Men with prostate cancer diagnosed between 2004-2012 and treated with either external beam radiation and/or prostate brachytherapy were abstracted from the National Cancer Database. In order to be included, men had to be clinically staged as T1c-T2aNx-0Mx-0, Gleason 6, PSA ≤ 10.0 ng/ml. Descriptive statistics were used to analyze brachytherapy utilization over time and were compared via χ(2). Multivariate logistic regression was used to assess for covariables associated with increased brachytherapy usage. There were 89,413 men included in this study, of which 37,054 (41.6%) received only external beam radiation, and 52,089 (58.4%) received prostate brachytherapy. The use of brachytherapy declined over time from 62.9% in 2004 to 51.3% in 2012 (p < 0.001). This decline was noted in both academic facilities (60.8% in 2004 to 47.0% in 2012, p < 0.001) as well as in non-academic facilities (63.7% in 2004 to 53.0% in 2012, p < 0.001). The decline was more pronounced in patients who lived closer to treatment facilities than those who lived further. The use of intensity modulated radiation therapy increased during this same time period from 18.4% in 2004 to 38.2% in 2012 (p < 0.001). On multivariate analysis, treatment at an academic center, increasing age, decreasing distance from the treatment center, and years of diagnosis from 2006-2012 were significantly associated with reduced brachytherapy usage. In this hospital-based registry, prostate brachytherapy usage has declined for low risk prostate cancer as intensity modulated radiation therapy usage has increased. However, it still remains the treatment of choice for 51.3% of patients as of 2012.
ERIC Educational Resources Information Center
Mancall, Jacqueline C.; Deskins, Dreama
This report assesses the impact of instruction in online bibliographic database searching on high school students' use of library materials and facilities in three Delaware secondary schools (one public, one parochial, and one private) during the spring of 1984. Most students involved in the analysis were given a brief explanation of online…
Microgravity research in NASA ground-based facilities
NASA Technical Reports Server (NTRS)
Lekan, Jack
1989-01-01
An overview of reduced gravity research performed in NASA ground-based facilities sponsored by the Microgravity Science and Applications Program of the NASA Office of Space Science and Applications is presented. A brief description and summary of the operations and capabilities of each of these facilities along with an overview of the historical usage of them is included. The goals and program elements of the Microgravity Science and Applications programs are described and the specific programs that utilize the low gravity facilities are identified. Results from two particular investigations in combustion (flame spread over solid fuels) and fluid physics (gas-liquid flows at microgravity conditions) are presented.
The Solar Energy Consortium of New York Photovoltaic Research and Development Center
DOE Office of Scientific and Technical Information (OSTI.GOV)
Klein, Petra M.
2012-10-15
Project Objective: To lead New York State to increase its usage of solar electric systems. The expected outcome is that appropriate technologies will be made available which in turn will help to eliminate barriers to solar energy usage in New York State. Background: The Solar Energy Consortium has been created to lead New York State research on solar systems specifically directed at doubling the efficiency, halving the cost and reducing the cost of installation as well as developing unique form factors for the New York City urban environment.
Yao, Jiandong; Zheng, Zhaoqiang; Yang, Guowei
2018-02-08
Solar energy-driven water evaporation lays a solid foundation for important photothermal applications such as sterilization, seawater desalination, and electricity generation. Due to the strong light-matter coupling, broad absorption wavelength range, and prominent quantum confinement effect, layered tin monoselenide (SnSe) holds a great potential to effectively harness solar irradiation and convert it to heat energy. In this study, SnSe is successfully deposited on a centimeter-scale nickel foam using a facile one-step pulsed-laser deposition approach. Importantly, the maximum evaporation rate of SnSe-coated nickel foam (SnSe@NF) reaches 0.85 kg m -2 h -1 , which is even 21% larger than that obtained with the commercial super blue coating (0.7 kg m -2 h -1 ) under the same condition. A systematic analysis reveals that its good photothermal conversion capability is attributed to the synergetic effect of multi-scattering-induced light trapping and the optimal trade-off between light absorption and phonon emission. Finally, the SnSe@NF device is further used for seawater evaporation, demonstrating a comparable evaporation rate (0.8 kg m -2 h -1 ) to that of fresh water and good stability over many cycles of usage. In summary, the current contribution depicts a facile one-step scenario for the economical and efficient solar-enabled SnSe@NF evaporation devices. More importantly, an in-depth analysis of the photothermal conversion mechanism underneath the layered materials depicts a fundamental paradigm for the design and application of photothermal devices based on them in the future.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Monsabert, S. de; Lemmer, H.; Dinwiddie, D.
1995-10-01
In the past, most buildings, structures, and ship visits were not metered, and flat estimates were calculated based on various estimating techniques. The decomposition process was further complicated by the fact that many of the meters monitor consumption values only and do not provide demand or time of use data. This method of billing provides no incentives to the PWC customers to implement energy conservation programs, including load shedding, Energy Monitoring and Control Systems (EMCS), building shell improvements, low flow toilets and shower heads, efficient lighting systems, or other energy savings alternatives. Similarly, the method had no means of adjustmentmore » for seasonal or climatic variations outside of the norm. As an alternative to flat estimates, the Customized Utility Billing Integrated Control (CUBIC) system and the Graphical Data Input System (GDIS) were developed to better manage the data to the major claimant area users based on utilities usage factors, building size, weather data, and hours of operation. GDIS is a graphical database that assists PWC engineers in the development and maintenance of single-line utility diagrams of the facilities and meters. It functions as a drawing associate system and is written in AutoLISP for AutoCAD version 12. GDIS interprets the drawings and provides the facility-to-meter and meter-to-meter hierarchy data that are used by the CUBIC to allocate the billings. This paper reviews the design, development and implementation aspects of CUBIC/GDIS and discusses the benefits of this improved utilities management system.« less
Survey of Hearth Products in U.S. Homes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Siap, David; Willem, Henry; Price, Sarah K.
There are over 7 million gas-fired fireplaces currently installed in US households. On an annual basis, these use substantial energy. However, the details of the fireplace energy use and the factors that influence it are currently not well understood. Fireplaces are a type of hearth product, which is a product category that primarily consists of fireplaces, stoves, and gas log sets. For the purpose of this study, the fuels used in hearth products are primarily natural gas, propane, or electricity. They may be vented or unvented. This study reports the results of a web survey of 2,100 respondents in themore » United States performed in February 2016. The responses were cleaned and weighted using the raking method to form a nationally representative population. The reported data include hearth product characteristics, usage information, and repair and maintenance practices. The hearth product characteristics include the hearth product type, fuel type, ignition system type, features, venting, and installation details. The usage information includes seasonal usage of the main burner and standing pilot (if present), daily usage, and the primary utility (whether decorative or for heating). These raw data are further processed and combined with values from the literature to estimate the annual operating hours and energy use and to assess how these are impacted by the hearth product type, features, age, and the main heating appliance, if present. Based on the survey responses, the estimated average annual hours of usage was 234 for the main burner, and 4,593 for the standing pilot. The results presented provide the most comprehensive data regarding hearth products in the United States published to date. These new data allow for an improved understanding of hearth products’ energy use, which in turn may facilitate the development of more informed analyses, and ultimately more efficient hearth products and reduced energy use. These new data also provide insight into topics not previously studied, such as the effect of hearth product features on energy use.« less
Energy Tracking Software Platform
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ryan Davis; Nathan Bird; Rebecca Birx
2011-04-04
Acceleration has created an interactive energy tracking and visualization platform that supports decreasing electric, water, and gas usage. Homeowners have access to tools that allow them to gauge their use and track progress toward a smaller energy footprint. Real estate agents have access to consumption data, allowing for sharing a comparison with potential home buyers. Home builders have the opportunity to compare their neighborhood's energy efficiency with competitors. Home energy raters have a tool for gauging the progress of their clients after efficiency changes. And, social groups are able to help encourage members to reduce their energy bills and helpmore » their environment. EnergyIT.com is the business umbrella for all energy tracking solutions and is designed to provide information about our energy tracking software and promote sales. CompareAndConserve.com (Gainesville-Green.com) helps homeowners conserve energy through education and competition. ToolsForTenants.com helps renters factor energy usage into their housing decisions.« less
Operating Dedicated Data Centers - Is It Cost-Effective?
NASA Astrophysics Data System (ADS)
Ernst, M.; Hogue, R.; Hollowell, C.; Strecker-Kellog, W.; Wong, A.; Zaytsev, A.
2014-06-01
The advent of cloud computing centres such as Amazon's EC2 and Google's Computing Engine has elicited comparisons with dedicated computing clusters. Discussions on appropriate usage of cloud resources (both academic and commercial) and costs have ensued. This presentation discusses a detailed analysis of the costs of operating and maintaining the RACF (RHIC and ATLAS Computing Facility) compute cluster at Brookhaven National Lab and compares them with the cost of cloud computing resources under various usage scenarios. An extrapolation of likely future cost effectiveness of dedicated computing resources is also presented.
The Effectiveness of Taiwan Building Energy Regulation under the influence of Future Climate
NASA Astrophysics Data System (ADS)
Weng, Yu-Teng; Huang, Kuo-Tsang
2017-04-01
Building energy consumption comprises circa 40% of the national annual energy usage in Taiwan, and the majority proportion is attributed to the cooling apparatus usage. As cooling energy is closely related to the outdoor climate, it is expected that the future global climate change would amplify its demand. Considering the building energy regulation criteria are the minimum requirements that the building has to be complied with, this study tried to investigate whether the current building energy regulation in Taiwan, initiated in 2013, would still be capable of maintaining the energy use in the future as today's level. The research adopted EnergyPlus to simulate the annual cooling energy use of several virtual office building cases with the constructed hourly future weather data under future climate change scenarios of RCP45 and RCP85 defined by IPCC. The virtual building cases are generated by a structured orthogonal array with each case is constituted by 10 building design parameters. The results revealed that the building energy consumption based on the current regulation criteria failed to maintain at the same level in the future as oppose to nowadays. By comparing to the current cooling energy usage, it would rise by 13% and 22% in RCP45 and RCP85, respectively, at the end of this century. This research further parametrically studied the potential cooling energy mitigation strategies and proposed effective building envelope design schemes in order to neutralize the future building energy increase.
NASA Astrophysics Data System (ADS)
Soetrisno, D. P.
2017-06-01
Pedestrian crossing facilities are effective enough to avoid pedestrians with vehicles, but its utilization is still quite low. It indicated that safety is not the only factor that influences a person to utilize the pedestrian crossing facilities. In addition, the availability of supporting elements of the pedestrian is still not quite attention, which is also became a factor that causes the pedestrians doesn’t utilize the pedestrian crossing facilities. Therefore, this research was structured to examine the relationship between the availability of the supporting elements of the pedestrian with pedestrian crossing facility usage based on user preferences. Data collection method used is primary survey consist of observation and the questionnaire. Sampling techniques used is purposive sampling with the number of respondents as many as 211 respondents by using questionnaire with ordinal scales to identify respondents’ consideration level of supporting elements pedestrian and crossing facility utilization factors. The survey is done on 15 crossing facilities area in 3 different locations with the same characteristics of land use in the form of higher education area (university area) and trades and services activities area. The analysis technique used is frequency distribution analysis in order to identify preference pedestrian on the availability of supporting elements of pedestrian and pedestrian crossing facility utilization factors, and chi square analysis is used to analyze the relationship between the availability of the supporting elements of the pedestrian with pedestrian crossing facility utilization. Based on the chi square analysis results with significance 5 % obtained the result that there are six supporting elements of pedestrian having correlation to the factors of pedestrian crossing facility utilization consist of the availability of sidewalk, pedestrian lights, Street Lighting Lamps, Pedestrian Crossing Markings Facilities, Sign Crossings Facilities, vegetation, and dustbin. So the result of this research can be considered for the government as main stakehoder especially the local government in preparing policy to provide supporting elements of pedestrian that should be on the area of pedestrian crossing facilities.
Energy monitoring system based on human activity in the workplace
NASA Astrophysics Data System (ADS)
Mustafa, Nur Hanim; Husain, Mohd Nor; Aziz, Mohamad Zoinol Abidin Abdul; Othman, Mohd Azlishah; Malek, Fareq
2015-05-01
Human behaviors always related to day routine activities in a smart house directly give the significant factor to manage energy usage in human life. An Addition that, the factor will contribute to the best efficiency of the system. This paper will focus on the monitoring efficiency based on duration time in office hours around 8am until 5pm which depend on human behavior at working place. Besides that, the correlation coefficient method is used to show the relation between energy consumption and energy saving based on the total hours of time energy spent. In future, the percentages of energy monitoring system usage will be increase to manage energy saving based on human behaviors. This scenario will help to see the human activity in the workplace in order to get the energy saving and support world green environment.
Energy monitoring based on human activity in the workplace
NASA Astrophysics Data System (ADS)
Mustafa, N. H.; Husain, M. N.; Abd Aziz, M. Z. A.; Othman, M. A.; Malek, F.
2014-04-01
Human behavior is the most important factor in order to manage energy usage. Nowadays, smart house technology offers a better quality of life by introducing automated appliance control and assistive services. However, human behaviors will contribute to the efficiency of the system. This paper will focus on monitoring efficiency based on duration time in office hours around 8am until 5pm which depend on human behavior atb the workplace. Then, the correlation coefficient method is used to show the relation between energy consumption and energy saving based on the total hours of time energy spent. In future, the percentages of energy monitoring system usage will be increase to manage energy in efficient ways based on human behaviours. This scenario will lead to the positive impact in order to achieve the energy saving in the building and support the green environment.
NASA Technical Reports Server (NTRS)
Stackhouse, Paul W., Jr.; Charles, Robert W.; Chandler, William S.; Hoell, James M.; Westberg, David; Zhang, Taiping; Ziegler, Urban; Leng, Gregory J.; Meloche, Nathalie; Bourque, Kevin
2012-01-01
This paper describes building energy system production and usage monitoring using examples from the new RETScreen Performance Analysis Module, called RETScreen Plus. The module uses daily meteorological (i.e., temperature, humidity, wind and solar, etc.) over a period of time to derive a building system function that is used to monitor building performance. The new module can also be used to target building systems with enhanced technologies. If daily ambient meteorological and solar information are not available, these are obtained over the internet from NASA's near-term data products that provide global meteorological and solar information within 3-6 days of real-time. The accuracy of the NASA data are shown to be excellent for this purpose enabling RETScreen Plus to easily detect changes in the system function and efficiency. This is shown by several examples, one of which is a new building at the NASA Langley Research Center that uses solar panels to provide electrical energy for building energy and excess energy for other uses. The system shows steady performance within the uncertainties of the input data. The other example involves assessing the reduction in energy usage by an apartment building in Sweden before and after an energy efficiency upgrade. In this case, savings up to 16% are shown.
NASA Astrophysics Data System (ADS)
Yan, Bo; Xu, Hui; Zhang, Ke; Li, Shujin; Wang, Jin; Shi, Yuting; Du, Yukou
2018-03-01
Self-supported PdCu alloy nanowires fabricated by a facile one-pot method have been reported, which copper assists in the morphological transformation from graininess to nanowires. The copper incorporated with palladium to form alloy structures cannot only cut down the usage of noble metal but also enhance their catalytic performances. The catalysts with self-supported structure and proper ratio of palladium to copper show great activity and long-term stability for the electrooxidation of ethylene glycol in alkaline solution. Especially for Pd43Cu57, its mass activity reaches to 5570.83 mA mg-1, which is 3.12 times as high as commercial Pd/C. This study highlights an accessible strategy to prepare self-supported PdCu alloy nanowires and their potential applications in renewable energy fields.
McGuckin, Maryanne; Waterman, Richard; Govednik, John
2009-01-01
Hand hygiene (HH) is the single most important factor in the prevention of health care-acquired infections. The 3 most frequently reported methods of measuring HH compliance are: (1) direct observation, (2) self-reporting by health care workers (HCWs), and (3) indirect calculation based on HH product usage. This article presents the results of a 12-month multicenter collaboration assessing HH compliance rates at US health care facilities by measuring product usage and providing feedback about HH compliance. Our results show that HH compliance at baseline was 26% for intensive care units (ICUs) and 36% for non-ICUs. After 12 months of measuring product usage and providing feedback, compliance increased to 37% for ICUs and 51% for non-ICUs. (ICU, P = .0119; non-ICU, P < .001). HH compliance in the United States can increase when monitoring is combined with feedback. However, HH still occurs at or below 50% compli- ance for both ICUs and non-ICUs.
Chen, Bowen; Zhao, Yongli; Zhang, Jie
2015-09-21
In this paper, we develop a virtual link priority mapping (LPM) approach and a virtual node priority mapping (NPM) approach to improve the energy efficiency and to reduce the spectrum usage over the converged flexible bandwidth optical networks and data centers. For comparison, the lower bound of the virtual optical network mapping is used for the benchmark solutions. Simulation results show that the LPM approach achieves the better performance in terms of power consumption, energy efficiency, spectrum usage, and the number of regenerators compared to the NPM approach.
ERIC Educational Resources Information Center
Lee, David G.
1974-01-01
Describes several successful attempts to utilize solar energy for heating and providing electrical energy for homes. Indicates that more research and development are needed, especially in the area of large scale usage. (SLH)
Woods, Susan S; Forsberg, Christopher W; Schwartz, Erin C; Nazi, Kim M; Hibbard, Judith H; Houston, Thomas K; Gerrity, Martha
2017-10-17
As electronic health records and computerized workflows expand, there are unprecedented opportunities to digitally connect with patients using secure portals. To realize the value of patient portals, initial reach across populations will need to be demonstrated, as well as sustained usage over time. The study aim was to identify patient factors associated with short-term and long-term portal usage after patients registered to access all portal functions. We prospectively followed a cohort of patients at a large Department of Veterans Affairs (VA) health care facility who recently completed identity proofing to use the VA patient portal. Information collected at baseline encompassed patient factors potentially associated with portal usage, including: demographics, Internet access and use, health literacy, patient activation, and self-reported health conditions. The primary outcome was the frequency of portal log-ins during 6-month and 18-month time intervals after study enrollment. A total of 270 study participants were followed prospectively. Almost all participants (260/268, 97.0%) reported going online, typically at home (248/268, 92.5%). At 6 months, 84.1% (227/270) of participants had visited the portal, with some variation in usage across demographic and health-related subgroups. There were no significant differences in portal log-ins by age, gender, education, marital status, race/ethnicity, distance to a VA facility, or patient activation measure. Significantly higher portal usage was seen among participants using high-speed broadband at home, greater self-reported ability using the Internet, and routinely going online. By 18 months, 91% participants had logged in to the portal, and no significant associations were found between usage and demographics, health status, or patient activation. When examining portal activity between 6 and 18 months, patients who were infrequent or high portal users remained in those categories, respectively. Short-term and long-term portal usage was associated with having broadband at home, high self-rated ability when using the Internet, and overall online behavior. Digital inclusion, or ready access to the Internet and digital skills, appears to be a social determinant in patient exposure to portal services. ©Susan S Woods, Christopher W Forsberg, Erin C Schwartz, Kim M Nazi, Judith H Hibbard, Thomas K Houston, Martha Gerrity. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 17.10.2017.
Improving Energy Security for Air Force Installations
NASA Astrophysics Data System (ADS)
Schill, David
Like civilian infrastructure, Air Force installations are dependent on electrical energy for daily operations. Energy shortages translate to decreased productivity, higher costs, and increased health risks. But for the United States military, energy shortages have the potential to become national security risks. Over ninety-five percent of the electrical energy used by the Air Force is supplied by the domestic grid, which is susceptible to shortages and disruptions. Many Air Force operations require a continuous source of energy, and while the Air Force has historically established redundant supplies of electrical energy, these back-ups are designed for short-term outages and may not provide sufficient supply for a longer, sustained power outage. Furthermore, it is the goal of the Department of Defense to produce or procure 25 percent of its facility energy from renewable sources by fiscal year 2025. In a government budget environment where decision makers are required to provide more capability with less money, it is becoming increasingly important for informed decisions regarding which energy supply options bear the most benefit for an installation. The analysis begins by exploring the field of energy supply options available to an Air Force installation. The supply options are assessed according to their ability to provide continuous and reliable energy, their applicability to unique requirements of Air Force installations, and their costs. Various methods of calculating energy usage by an installation are also addressed. The next step of this research develops a methodology and tool which assesses how an installation responds to various power outage scenarios. Lastly, various energy supply options are applied to the tool, and the results are reported in terms of cost and loss of installation capability. This approach will allow installation commanders and energy managers the ability to evaluate the cost and effectiveness of various energy investment options.
The impact of electric vehicles on the outlook of future energy system
NASA Astrophysics Data System (ADS)
Zhuk, A.; Buzoverov, E.
2018-02-01
Active promotion of electric vehicles (EVs) and technology of fast EV charging in the medium term may cause significant peak loads on the energy system, what necessitates making strategic decisions related to the development of generating capacities, distribution networks with EV charging infrastructure, and priorities in the development of battery electric vehicles and vehicles with electrochemical generators. The paper analyses one of the most significant aspects of joint development of electric transport system and energy system in the conditions of substantial growth of energy consumption by EVs. The assessments of per-unit-costs of operation and depreciation of EV power unit were made, taking into consideration the expenses of electric power supply. The calculations show that the choice of electricity buffering method for EV fast charging depends on the character of electricity infrastructure in the region where the electric transport is operating. In the conditions of high density of electricity network and a large number of EVs, the stationary storage facilities or the technology of distributed energy storage in EV batteries - vehicle-to-grid (V2G) technology may be used for buffering. In the conditions of low density and low capacity of electricity networks, the most economical solution could be usage of EVs with traction power units based on the combination of air-aluminum electrochemical generator and a buffer battery of small capacity.
Liquid Metal Fast Breeder Reactor Program: Argonne facilities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stephens, S. V.
1976-09-01
The objective of the document is to present in one volume an overview of the Argonne National Laboratory test facilities involved in the conduct of the national LMFBR research and development program. Existing facilities and those under construction or authorized as of September 1976 are described. Each profile presents brief descriptions of the overall facility and its test area and data relating to its experimental and testing capability. The volume is divided into two sections: Argonne-East and Argonne-West. Introductory material for each section includes site and facility maps. The profiles are arranged alphabetically by title according to their respective locationsmore » at Argonne-East or Argonne-West. A glossary of acronyms and letter designations in common usage to describe organizations, reactor and test facilities, components, etc., involved in the LMFBR program is appended.« less
Reducing Operating Costs and Energy Consumption at Water Utilities
Due to their unique combination of high energy usage and potential for significant savings, utilities are turning to energy-efficient technologies to help save money. Learn about cost and energy saving technologies from this brochure.
Activities Handbook for Energy Education.
ERIC Educational Resources Information Center
DeVito, Alfred; Krockover, Gerald H.
The purpose of this handbook is to present information about energy and to translate this information into learning activities for children. Chapter 1, "Energy: A Delicate Dilemma," presents activities intended to provide an introduction to energy and energy usage. Chapter 2, "What are the Sources of Energy?" provides…
Inductive flux usage and its optimization in tokamak operation
Luce, Timothy C.; Humphreys, David A.; Jackson, Gary L.; ...
2014-07-30
The energy flow from the poloidal field coils of a tokamak to the electromagnetic and kinetic stored energy of the plasma are considered in the context of optimizing the operation of ITER. The goal is to optimize the flux usage in order to allow the longest possible burn in ITER at the desired conditions to meet the physics objectives (500 MW fusion power with energy gain of 10). A mathematical formulation of the energy flow is derived and applied to experiments in the DIII-D tokamak that simulate the ITER design shape and relevant normalized current and pressure. The rate ofmore » rise of the plasma current was varied, and the fastest stable current rise is found to be the optimum for flux usage in DIII-D. A method to project the results to ITER is formulated. The constraints of the ITER poloidal field coil set yield an optimum at ramp rates slower than the maximum stable rate for plasmas similar to the DIII-D plasmas. Finally, experiments in present-day tokamaks for further optimization of the current rise and validation of the projections are suggested.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Racine, W.C.; Campillo, C.J.
During the site-selection phase of the Onsite Fuel-Cell Field Test, nearly one hundred sites throughout the U.S. were each instrumented with a standard data-acquisition system (DAS) to collect hourly electrical and thermal data for one year. Seventy of those sites are included in the report. Each site's electrical and thermal systems were instrumented including ambient temperature, electrical demands, building gas usage, and other parameters necessary to calculate building thermal loads. Multifamily residential, commercial, and light industrial sites were instrumented. Approximately twenty market sectors were represented including restaurants, hospitals, hotels, apartments, health clubs, nursing homes, and food-processing plants. The primary usemore » of the data was to determine site compatibility for the installation of 40-kW fuel-cell power plants. However, the collected energy data and site-specific information summarized in this comprehensive report may also be useful for other applications such as market characterization and simulation of new or improved energy-utilization equipment in actual sites. This volume covers metal-plating facilities, nurseries, nursing homes, office buildings and other industrial applications.« less
Energy System Integration Facility Secure Data Center | Energy Systems
Integration Facility | NREL Energy System Integration Facility Secure Data Center Energy System Integration Facility Secure Data Center The Energy Systems Integration Facility's Secure Data Center provides
Energy Systems Integration Facility Control Room | Energy Systems
Integration Facility | NREL Energy Systems Integration Facility Control Room Energy Systems Integration Facility Control Room The Energy Systems Integration Facility control room allows system engineers as the monitoring point for the facility's integrated safety and control systems. Photo of employees
Writing Apprehension, Computer Anxiety and Telecomputing: A Pilot Study.
ERIC Educational Resources Information Center
Harris, Judith; Grandgenett, Neal
1992-01-01
A study measured graduate students' writing apprehension and computer anxiety levels before and after using electronic mail, computer conferencing, and remote database searching facilities during an educational technology course. Results indicted postcourse computer anxiety levels significantly related to usage statistics. Precourse writing…
Sidney, Kristi; Ryan, Kayleigh; Diwan, Vishal; De Costa, Ayesha
2014-01-01
In 2009 the state government of Madhya Pradesh, India launched an emergency obstetric transportation service, Janani Express Yojana (JEY), to support the cash transfer program that promotes institutional delivery. JEY, a large scale public private partnership, lowers geographical access barriers to facility based care. The state contracts and pays private agencies to provide emergency transportation at no cost to the user. The objective was to study (a) the utilization of JEY among women delivering in health facilities, (b) factors associated with usage, (c) the timeliness of the service. A cross sectional facility based study was conducted in facilities that carried out > ten deliveries a month. Researchers who spent five days in each facility administered a questionnaire to all women who gave birth there to elicit socio-demographic characteristics and transport related details. 35% of women utilised JEY to reach a facility, however utilization varied between study districts. Uptake was highest among women from rural areas (44%), scheduled tribes (55%), and poorly educated women (40%). Living in rural areas and belonging to scheduled tribes were significant predictors for JEY usage. Almost 1/3 of JEY users (n = 104) experienced a transport related delay. The JEY service model complements the cash transfer program by providing transport to a facility to give birth. A study of the distribution of utilization in population subgroups suggests the intervention was successful in reaching the most vulnerable population, promoting equity in access. While 1/3 of women utilized the service and it saved them money; 30% experienced significant transport related delays in reaching a facility, which is comparable to women using public transportation. Further research is needed to understand why utilization is low, to explore if there is a need for service expansion at the community level and to improve the overall time efficiency of JEY.
Newton, Joshua D; Klein, Ruth; Bauman, Adrian; Newton, Fiona J; Mahal, Ajay; Gilbert, Kara; Piterman, Leon; Ewing, Michael T; Donovan, Robert J; Smith, Ben J
2015-04-18
Physical activity is associated with a host of health benefits, yet many individuals do not perform sufficient physical activity to realise these benefits. One approach to rectifying this situation is through modifying the built environment to make it more conducive to physical activity, such as by building walking tracks or recreational physical activity facilities. Often, however, modifications to the built environment are not connected to efforts aimed at encouraging their use. The purpose of the Monitoring and Observing the Value of Exercise (MOVE) study is to evaluate the effectiveness of two interventions designed to encourage the ongoing use of a new, multi-purpose, community-based physical activity facility. A two-year, randomised controlled trial with yearly survey points (baseline, 12 months follow-up, 24 months follow-up) will be conducted among 1,300 physically inactive adult participants aged 18-70 years. Participants will be randomly assigned to one of three groups: control, intervention 1 (attendance incentives), or intervention 2 (attendance incentives and tailored support following a model based on customer relationship management). Primary outcome measures will include facility usage, physical activity participation, mental and physical wellbeing, community connectedness, social capital, friendship, and social support. Secondary outcome measures will include stages of change for facility usage and social cognitive decision-making variables. This study will assess whether customer relationship management systems, a tool commonly used in commercial marketing settings, can encourage the ongoing use of a physical activity facility. Findings may also indicate the population segments among which the use of such systems are most effective, as well as their cost-effectiveness. Australian New Zealand Clinical Trials Registry: ACTRN12615000012572 (registered 9 January 2015).
New approaches to spatially analyse primary health care usage patterns in rural South Africa.
Tanser, F; Hosegood, V; Benzler, J; Solarsh, G
2001-10-01
To develop indices to quantitatively assess and understand the spatial usage patterns of health facilities in the Hlabisa district of South Africa. We mapped and interviewed more than 23 000 homesteads (approximately 200 000 people) in Hlabisa district, South Africa and spatially analysed their modal primary health usage patterns using a geographical information system. We generated contour maps of health service use and quantified the relationship between clinic catchments and distance-defined catchments using inclusion and exclusion error. We propose the distance usage index (DUI) as an overall spatial measure of clinic usage. This index is the sum of the distances from clinic to all client homesteads divided by the sum of the distances from clinic to all homesteads within its distance-defined catchment. The index encompasses inclusion, exclusion, and strength of patient attraction for each clinic. Eighty-seven per cent of homesteads use the nearest clinic. Residents of homesteads travel an average Euclidean distance of 4.72 km to attend clinics. There is a significant logarithmic relationship between distance from clinic and their use by homesteads (r(2)=0.774, P < 0.0001). The DUI values range between 31 and 198% (mean=110%, SD=43.7) for 12 clinics and highlight clinic usage patterns across the district. The DUI is a powerful and informative composite measure of clinic usage. The results of the study have important implications for health care provision in developing countries.
Process wastewater treatability study for Westinghouse fluidized-bed coal gasification
DOE Office of Scientific and Technical Information (OSTI.GOV)
Winton, S.L.; Buvinger, B.J.; Evans, J.M.
1983-11-01
In the development of a synthetic fuels facility, water usage and wastewater treatment are major areas of concern. Coal gasification processes generally produce relatively large volumes of gas condensates. These wastewaters are typically composed of a variety of suspended and dissolved organic and inorganic solids and dissolved gaseous contaminants. Fluidized-bed coal gasification (FBG) processes are no exception to this rule. The Department of Energy's Morgantown Energy Technology Center (METC), the Gas Research Institute (GRI), and the Environmental Protection Agency (EPA/IERLRTP) recognized the need for a FBG treatment program to provide process design data for FBG wastewaters during the environmental, health,more » and safety characterization of the Westinghouse Process Development Unit (PDU). In response to this need, METC developed conceptual designs and a program plan to obtain process design and performance data for treating wastewater from commercial-scale Westinghouse-based synfuels plants. As a result of this plan, METC, GRI, and EPA entered into a joint program to develop performance data, design parameters, conceptual designs, and cost estimates for treating wastewaters from a FBG plant. Wastewater from the Westinghouse PDU consists of process quench and gas cooling condensates which are similar to those produced by other FBG processes such as U-Gas, and entrained-bed gasification processes such as Texaco. Therefore, wastewater from this facility was selected as the basis for this study. This paper outlines the current program for developing process design and cost data for the treatment of these wastewaters.« less
Current On-Campus Attitudes toward Energy Usage, Efficiency, and Emerging Technologies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lennon, Liz; Sintov, Nicole; Orosz, Michael
Context & Background for Energy Survey Methods & Survey Overview Respondent Demographics Results Demand Response Current Environmental Comfort Perceptions Smart Meters Perceived Smart Meter Benefits Motivators of Energy Efficient Practices Summary & Implications
Vanhegan, Ivor S; Palmer-Green, Debbie; Soligard, Torbjørn; Steffen, Kathrin; O'Connor, Philip; Bethapudi, Sarath; Budgett, Richard; Haddad, Fares S; Engebretsen, Lars
2013-05-01
The London 2012 Summer Olympic Games involved 10 568 elite athletes representing 204 competing nations. To manage the varied healthcare needs of this diverse population, a Polyclinic was constructed in the athletes' village. This work aims to summarise the usage of the Polyclinic by competing athletes and the facilities available to them. All Polyclinic encounters were entered into a database from which data were exported for the time frame 28 July-12 August 2012, inclusive to cover the first to last full day of competition. Only Polyclinic data involving accredited athletes were analysed. All types of encounters were collected for analysis, not just sports-related issues. There were a total of 3220 encounters within the Polyclinic. This figure combines medical consultations, radiology/pathology investigations and prescriptions dispensed. Of these 3220 encounters, there were 2105 medical consultations; musculoskeletal comprised the greatest number (52%), followed by dental (30%) and ophthalmic (9%). The most frequently used imaging modality was MRI and diagnostic CT was used the least. After correction for multiple entries, Africa provided the largest proportion of athletes attending the Polyclinic (44%) and Europe the least (9%). Peak usage of all facilities was seen around days 9 and 10 of competition, reflecting the busiest time of the competition and the largest number of athletes in the village. The Polyclinic managed a wide variety of both sports-related and non-sports-related injuries and illnesses. The breadth of specialists available for consultation was appropriate as was the ease of access to them. The radiology department was able to satisfy the demand, as were the pharmacy and pathology services. We would recommend a similar structure of facilities and available expertise in one clinic when planning future mass participation sporting events.
NASA Astrophysics Data System (ADS)
Meng, M.; Macknick, J.; Tidwell, V. C.; Zagona, E. A.; Magee, T. M.; Bennett, K.; Middleton, R. S.
2017-12-01
The U.S. electricity sector depends on large amounts of water for hydropower generation and cooling thermoelectric power plants. Variability in water quantity and temperature due to climate change could reduce the performance and reliability of individual power plants and of the electric grid as a system. While studies have modeled water usage in power systems planning, few have linked grid operations with physical water constraints or with climate-induced changes in water resources to capture the role of the energy-water nexus in power systems flexibility and adequacy. In addition, many hydrologic and hydropower models have a limited representation of power sector water demands and grid interaction opportunities of demand response and ancillary services. A multi-model framework was developed to integrate and harmonize electricity, water, and climate models, allowing for high-resolution simulation of the spatial, temporal, and physical dynamics of these interacting systems. The San Juan River basin in the Southwestern U.S., which contains thermoelectric power plants, hydropower facilities, and multiple non-energy water demands, was chosen as a case study. Downscaled data from three global climate models and predicted regional water demand changes were implemented in the simulations. The Variable Infiltration Capacity hydrologic model was used to project inflows, ambient air temperature, and humidity in the San Juan River Basin. Resulting river operations, water deliveries, water shortage sharing agreements, new water demands, and hydroelectricity generation at the basin-scale were estimated with RiverWare. The impacts of water availability and temperature on electric grid dispatch, curtailment, cooling water usage, and electricity generation cost were modeled in PLEXOS. Lack of water availability resulting from climate, new water demands, and shortage sharing agreements will require thermoelectric generators to drastically decrease power production, as much as 50% during intensifying drought scenarios, which can have broader electricity sector system implications. Results relevant to stakeholder and power provider interests highlight the vulnerabilities in grid operations driven by water shortage agreements and changes in the climate.
Creation of a U.S. Phosphorescent OLED Lighting Panel Manufacturing Facility
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hack, Michael
Universal Display Corporation (UDC) has pioneered high efficacy phosphorescent OLED (PHOLED™) technology to enable the realization of an exciting new form of high quality, energy saving solid-date lighting. In laboratory test devices, we have demonstrated greater than 100 lm/W conversion efficacy. In this program, Universal Display will demonstrate the scalability of its proprietary UniversalPHOLED technology and materials for the manufacture of white OLED lighting panels that meet commercial lighting targets. Moser Baer Technologies will design and build a U.S.- based pilot facility. The objective of this project is to establish a pilot phosphorescent OLED (PHOLED) manufacturing line in the U.S.more » Our goal is that at the end of the project, prototype lighting panels could be provided to U.S. luminaire manufacturers for incorporation into products to facilitate the testing of design concepts and to gauge customer acceptance, so as to facilitate the growth of the embryonic U.S. OLED lighting industry. In addition, the team will provide a cost of ownership analysis to quantify production costs including OLED performance metrics which relate to OLED cost such as yield, materials usage, cycle time, substrate area, and capital depreciation. This project was part of a new DOE initiative designed to help establish and maintain U.S. leadership in this program will support key DOE objectives by showing a path to meet Department of Energy Solid-State Lighting Manufacturing Roadmap cost targets, as well as meeting its efficiency targets by demonstrating the energy saving potential of our technology through the realization of greater than 76 lm/W OLED lighting panels by 2012.« less
Yahoo! Compute Coop (YCC). A Next-Generation Passive Cooling Design for Data Centers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Robison, AD; Page, Christina; Lytle, Bob
The purpose of the Yahoo! Compute Coop (YCC) project is to research, design, build and implement a greenfield "efficient data factory" and to specifically demonstrate that the YCC concept is feasible for large facilities housing tens of thousands of heat-producing computing servers. The project scope for the Yahoo! Compute Coop technology includes: - Analyzing and implementing ways in which to drastically decrease energy consumption and waste output. - Analyzing the laws of thermodynamics and implementing naturally occurring environmental effects in order to maximize the "free-cooling" for large data center facilities. "Free cooling" is the direct usage of outside air tomore » cool the servers vs. traditional "mechanical cooling" which is supplied by chillers or other Dx units. - Redesigning and simplifying building materials and methods. - Shortening and simplifying build-to-operate schedules while at the same time reducing initial build and operating costs. Selected for its favorable climate, the greenfield project site is located in Lockport, NY. Construction on the 9.0 MW critical load data center facility began in May 2009, with the fully operational facility deployed in September 2010. The relatively low initial build cost, compatibility with current server and network models, and the efficient use of power and water are all key features that make it a highly compatible and globally implementable design innovation for the data center industry. Yahoo! Compute Coop technology is designed to achieve 99.98% uptime availability. This integrated building design allows for free cooling 99% of the year via the building's unique shape and orientation, as well as server physical configuration.« less
ERIC Educational Resources Information Center
Abelson, Philip H.
1973-01-01
Discussed in this editorial is the need for a broad and detailed government policy on energy use. Oil companies can not be given complete responsibility to demonstrate usage of different energy sources. The government should construct plants because energy is connected with national security. (PS)
Promoting hand hygiene and prudent use of antimicrobials in long-term care facilities.
Rummukainen, Maija; Jakobsson, Aino; Karppi, Pertti; Kautiainen, Hannu; Lyytikäinen, Outi
2009-03-01
A multidisciplinary team visited all long-term care facilities (n = 123) for elderly persons in the Central Finland health care district (population, 265,000) during 2004-2005. Use of alcohol-based hand rubs and ongoing systematic antimicrobials were assessed. Thereafter, regional guidelines for prudent use of antimicrobials were published. One year after the visits, a significant increase in the mean amount of alcohol-based hand rubs used was detected while usage of antimicrobials for the prevention of urinary tract reinfections had decreased.
47 CFR 5.402 - Eligibility and usage.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL EXPERIMENTAL RADIO SERVICE Medical Testing Experimental... health care facilities as defined in § 95.1103(b) of this chapter. (b) Medical testing experimental radio... limited to testing equipment designed to comply with the rules in part 15, Radio Frequency Devices; part...
47 CFR 5.402 - Eligibility and usage.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL EXPERIMENTAL RADIO SERVICE Medical Testing Experimental... health care facilities as defined in § 95.1103(b) of this chapter. (b) Medical testing experimental radio... limited to testing equipment designed to comply with the rules in part 15, Radio Frequency Devices; part...
The Ins and Outs of Access Control.
ERIC Educational Resources Information Center
Longworth, David
1999-01-01
Presents basic considerations when school districts plan to acquire an access-control system for their education facilities. Topics cover cards and readers, controllers, software, automation, card technology, expandability, price, specification of needs beyond the canned specifications already supplied, and proper usage training to cardholders.…
Evaluating School Library Information Services in the Digital Age.
ERIC Educational Resources Information Center
Everhart, Nancy
2000-01-01
Discusses criteria for evaluating school library information services. Highlights include types of services; physical facilities; library usage; circulation statistics; changes due to technology; fill rate, or the percentage of successful searches for library materials; OPAC (online public access catalog) reports; observation; and examining…
Preliminary fuel use results from gin audits
USDA-ARS?s Scientific Manuscript database
Interest in improving sustainability in cotton production and processing has focused attention on fuel use by cotton gins for seed cotton drying. Audits are planned for multiple gin facilities over a diverse geography to establish baseline fuel usage and drying system efficiencies to reveal opportu...
NASA Astrophysics Data System (ADS)
Kendie, S. B.
1996-01-01
In the examination of the implementation of rural drinking water facilities, not enough attention has been paid to analyzing the socioeconomic and political relationships that affect the effective utilization of the facilities, particularly as these relate to women in rural society. This paper suggests that much of the difficulty in instituting the utilization of safe water supply sources has to do with the rather low economic status of women—the main water collectors. Poverty consigns women to long periods of work in activities or jobs that bring little reward. This makes it difficult to effectively digest the messages delivered by program staff and limits the extent of usage of the safe water facilities.
Overview of Fuel Rod Simulator Usage at ORNL
NASA Astrophysics Data System (ADS)
Ott, Larry J.; McCulloch, Reg
2004-02-01
During the 1970s and early 1980s, the Oak Ridge National Laboratory (ORNL) operated large out-of-reactor experimental facilities to resolve thermal-hydraulic safety issues in nuclear reactors. The fundamental research ranged from material mechanical behavior of fuel cladding during the depressurization phase of a loss-of-coolant accident (LOCA) to basic heat transfer research in gas- or sodium-cooled cores. The largest facility simulated the initial phase (less than 1 min. of transient time) of a LOCA in a commercial pressurized-water reactor. The nonnuclear reactor cores of these facilities were mimicked via advanced, highly instrumented electric fuel rod simulators locally manufactured at ORNL. This paper provides an overview of these experimental facilities with an emphasis on the fuel rod simulators.
Development of electro-optic systems for self cleaning concentrated solar reflectors
NASA Astrophysics Data System (ADS)
Stark, Jeremy W.
The current demand for energy usage in the world is increasing at a rapid pace; in China alone, the electricity usage has increased by 12% per year from 2006-2010, where more than 75% of electrical power is produced by coal burning facilities. Numerous studies have shown the effects of carbon dioxide emissions on global climate change, and even showing the permanence of high carbon dioxide levels after emissions cease. Current trends away from carbon emitting power facilities are pushing solar energy into a position for many new solar power plants to be constructed. Terrestrial solar energy at AM1.5 is generally given at 1kW/m2, which is a vast free source of energy that can be be harvested to meet the global demand for electricity. Aside from some areas receiving intermittent levels of solar insolation, one of the largest hindrances to large scale solar power production is obscuration of sunlight on solar collectors caused by dust deposition. In areas with the highest average solar insolation, dust deposition is a major problem for maintaining a constant maximum power output. The southern Negev desert in Israel receives on average 17g/m2 per month in dust deposition on solar installations, which in turn causes losses of a third of the total power output of the installation. In these areas, water is a scarce commodity, which can only be used to clean solar installations at a prohibitive cost. To resolve this problem, a cost effective solution would be the application of electrodynamic screens (EDS), which can be implemented by embedding a set of parallel electrodes into the sun facing surface of solar collectors, including concentrating mirrors or photovoltaic (PV) modules, and applying a low frequency pulsed voltage to these electrodes. Three major contributions made in the course of this research in advancing (EDS) for self-cleaning solar mirrors are: (1) development of non-contact specular reflectometer for solar mirrors that allows measurement of reflectance loss as a function of dust deposition, (2) development of a dust deposition analyzer capable of measuring size distribution of deposited dust and provides mass concentration of dust on the surface of the mirror, and (3) optimization of electrode geometry of EDS film for minimizing optical reflection losses caused by the lamination of the film on the mirror surface while maintaining high reflection efficiency with high dust removal efficiency. The non-contact specular reflectometer and the dust deposition analyzer allowed experimental investigation of reflection losses as functions of surface mass concentration of dust on mirrors for validation of the optical model presented in this study.
Energy Systems Integration Facility Videos | Energy Systems Integration
Facility | NREL Energy Systems Integration Facility Videos Energy Systems Integration Facility Integration Facility NREL + SolarCity: Maximizing Solar Power on Electrical Grids Redefining What's Possible for Renewable Energy: Grid Integration Robot-Powered Reliability Testing at NREL's ESIF Microgrid
Mobile Phone Usage and its Health Effects Among Adults in a Semi-Urban Area of Southern India.
Stalin, P; Abraham, Sherin Billy; Kanimozhy, K; Prasad, R Vishnu; Singh, Zile; Purty, Anil J
2016-01-01
Worldwide, mobile phone usage has been increased dramatically which could affect the health of the people. India has the second largest number of mobile phone users. However there are only few studies conducted in India to assess its effects on health. To determine the prevalence and pattern of mobile phone usage and to assess the relationship between certain selected health problems and mobile phone usage among adults. Community-based cross-sectional study was conducted in Kottakuppam, a town panchayat in Villupuram district of Coastal Tamil Nadu, Southern India. It is a semi-urban area with a population of about 16,000. Majority of the residents are Muslim by religion and belong to different socio economic status. The study was approved by the Institutional Ethics Committee. A total of 2121 study participants were interviewed by the pre-final medical students through house-to-house survey using a pretested structured questionnaire. The questionnaire included the variables such as socio demographic profile, mobile phone usage and pattern, selected health problems, perceived benefits and threats and blood pressure. Selected health problems included headache, earache, neck pain, tinnitus, painful fingers, restlessness, morning tiredness, tingling fingers, fatigue, eye symptoms, sleep disturbance and hypertension. Only 2054 were included for data analysis using SPSS 17 version. Proportions were calculated. Chi-square test was used to measure the p-value. The p-value < 0.05 was considered as statistically significant. The prevalence of mobile phone usage was 70%. Calling facility (94.2%) was used more than the SMS (67.6%). Health problems like headache, earache, tinnitus, painful fingers and restlessness etc., were found to be positively associated with mobile phone usage. There was negative association between hypertension and mobile phone usage. The prevalence of mobile phone usage was high. There was significant association between selected health problems and mobile phone usage. In future, higher studies are required to confirm our findings.
Guler, N; Volegov, P; Danly, C R; Grim, G P; Merrill, F E; Wilde, C H
2012-10-01
Inertial confinement fusion experiments at the National Ignition Facility are designed to understand the basic principles of creating self-sustaining fusion reactions by laser driven compression of deuterium-tritium (DT) filled cryogenic plastic capsules. The neutron imaging diagnostic provides information on the distribution of the central fusion reaction region and the surrounding DT fuel by observing neutron images in two different energy bands for primary (13-17 MeV) and down-scattered (6-12 MeV) neutrons. From this, the final shape and size of the compressed capsule can be estimated and the symmetry of the compression can be inferred. These experiments provide small sources with high yield neutron flux. An aperture design that includes an array of pinholes and penumbral apertures has provided the opportunity to image the same source with two different techniques. This allows for an evaluation of these different aperture designs and reconstruction algorithms.
Cloud@Home: A New Enhanced Computing Paradigm
NASA Astrophysics Data System (ADS)
Distefano, Salvatore; Cunsolo, Vincenzo D.; Puliafito, Antonio; Scarpa, Marco
Cloud computing is a distributed computing paradigm that mixes aspects of Grid computing, ("… hardware and software infrastructure that provides dependable, consistent, pervasive, and inexpensive access to high-end computational capabilities" (Foster, 2002)) Internet Computing ("…a computing platform geographically distributed across the Internet" (Milenkovic et al., 2003)), Utility computing ("a collection of technologies and business practices that enables computing to be delivered seamlessly and reliably across multiple computers, ... available as needed and billed according to usage, much like water and electricity are today" (Ross & Westerman, 2004)) Autonomic computing ("computing systems that can manage themselves given high-level objectives from administrators" (Kephart & Chess, 2003)), Edge computing ("… provides a generic template facility for any type of application to spread its execution across a dedicated grid, balancing the load …" Davis, Parikh, & Weihl, 2004) and Green computing (a new frontier of Ethical computing1 starting from the assumption that in next future energy costs will be related to the environment pollution).
Medium Duty ARRA Data Reporting and Analysis; NREL (National Renewable Energy Laboratory)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kelly, Kenneth; Duran, Adam; Ragatz, Adam
Medium-duty (MD) electric vehicle (EV) data collection and analysis will help drive design, purchase, and research investments. Over 4 million miles and 160,000 driving days of EV driving data were collected under this project. Publicly available data help drive technology research, development, and deployment. Feeding the vocational database for future analysis will lead to a better understanding of usage and will result in better design optimization and technology implementation. The performance of a vehicle varies with drive cycle and cargo load - MD vehicles are 'multi-functional.' Environment and accessory loads affect vehicle range and in turn add cost by addingmore » battery capacity. MD EV vehicles can function in vocations traditionally serviced by gasoline or diesel vehicles. Facility implications (i.e., demand charges) need to be understood as part of site-based analysis for EV implementation.« less
Martin, Barry A; Delva, Nicholas John; Graf, Peter; Gosselin, Caroline; Enns, Murray W; Gilron, Ian; Jewell, Mark; Lawson, James Stuart; Milev, Roumen; Patry, Simon; Chan, Peter K Y
2015-06-01
The aims of this study were to document electroconvulsive therapy use in Canada with respect to treatment facilities and caseloads based on a survey of practice (Canadian Electroconvulsive Therapy Survey/Enquete Canadienne Sur Les Electrochocs-CANECTS/ECANEC) and to consider these findings in the context of guideline recommendations. All 1273 registered hospitals in Canada were contacted, and 175 sites were identified as providing electroconvulsive therapy; these sites were invited to complete a comprehensive questionnaire. The survey period was calendar year 2006 or fiscal year 2006/2007. National usage rates were estimated from the responses. Sixty-one percent of the sites completed the questionnaire; a further 10% provided caseload data. Seventy were identified as general; 31, as university teaching; and 21, as provincial psychiatric/other single specialty (psychiatric) hospitals. Caseload volumes ranged from a mean of fewer than 2 to greater than 30 treatments per week. Estimated national usage during the 1-year survey period was 7340 to 8083 patients (2.32-2.56 per 10,000 population) and 66,791 to 67,424 treatments (2.11-2.13 per 1000 population). The diagnostic indications, admission status, and protocols for course end points are described. The usage rates are in keeping with earlier Canadian data and with those from other jurisdictions. The difficulty obtaining caseload data from individual hospitals is indicative of the need for standardized data collection to support both clinical research and quality assurance. The wide variation in protocols for number of treatments per course indicates a need for better informed clinical guidelines. The broad range of caseload volumes suggests the need to review the economies of scale in the field.
Hambisa, Mitiku Teshome; Debela, Tessema; Dessie, Yadeta; Gobena, Tesfaye
2018-01-10
Many countries in sub-Saharan Africa, including Ethiopia, are focusing on the distribution of Long Lasting Insecticidal Nets (LLINs) to combat malaria. However, utilization of the LLIN is low when compared with LLIN possession because of various factors. This study was conducted to measure the actual LLIN usage and identify factors associated with its utilization in Limmu Seka District, South West Ethiopia. A community based cross-sectional survey was conducted among 830 households from December 25, 2011 to February 29, 2012. A total of 830 households were selected by stratified systematic sampling and surveyed. Ninety percent of those surveyed owned LLINs and 68.3% reported that someone had slept under the net on the night prior to the survey. The factors associated with LLIN usage were knowledge of the mode of malaria transmission (AOR; 0.086, 95% CI 0.03, 0.24), the preferred conical shapes of the LLIN (AOR; 1.6, 95% CI 1.31, 4.1), receiving information about their use from Health Extension Workers (HEWs) (AOR; 2.4, 95% CI 1.5, 3.9), hearing media campaigns (AOR; 3.2 95% CI 3.5, 9.2), education at a health facility (AOR; 2 95% CI 1.5, 3.9) or having a family size of three or less (AOR; 2.1, 95% CI 1.3, 3.5). Although ownership of Long Lasting Insecticidal Nets was high at 90%, the actual usage of LLIN was low, and not all family members were protected. Promoting the usage of LLINs utilization by those at most risk, especially the conical shaped ones, through intensified health education using HEWs and mass media campaigns at all health facilities, schools and communities will improve LLIN utilization.
Final Scientific Technical Report Crowder College MARET Center
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boyt, Art; Eberle, Dan; Hudson, Pam
Following decades of success in solar energy projects, the Missouri Legislature designated Crowder College in 1992 as the State's renewable energy education center. The resulting Missouri Alternative and Renewable Energy Technology (MARET) Center is recognized internationally for its contributions to the energy field. The mission of the MARET Center is to expand renewable energy throughout the region with education, applied research, and economic development. Educational programs include certification and transfer degrees encompassing green construction, solar thermal energy, solar electricity, and wind. The MARET Center also assists in new product development and other business support services in renewable energy. The Missourimore » Alternative and Renewable Energy Technology (MARET) Center at Crowder College hopes to eventually develop a 27,500 ft 2 facility as a living laboratory to support solar and other renewable and sustainable energy development through professional degrees, new product development and commercialization, renewable energy business incubation, and consumer education. The primary objective of the current project was to complete Stage One of this building, with solar, wind, and geothermal technologies installed to power its 9,216 ft 2 office, classroom, and research spaces. This MARET Center includes a modular roof structure that permits both solar module mounting and daylighting, PV/thermal hybrid modules pioneered in Crowder Solar Decathlon homes, modular electrical management subsystems; and modular delivery systems for heating and cooling the structure. The MARET Facility will operate as a Net Positive energy building, consistently producing surplus energy for distributed generation on the utility grid. The modular design of the energy systems within the building is to serve as a scalable and repeatable model for a wide variety of building applications and climate zones. As a living laboratory of renewable energy, exploring and validating new applications of solar and other renewable technologies, the MARET Facility will house a wide variety of programs which will advance implementation of renewable energy throughout the region. These program goals include; Curriculum in renewable energy for pre-engineering transfer programs; Certification and degree programs for technical degrees for Energy Efficiency, Wind, Photovoltaic and Solar Thermal professionals; Short courses and workshops for building management and design professionals; Public education and demonstration projects in renewable energy through conferences and K-12 educational outreach; Technical degree offering in building construction incorporating “best practices” for energy efficiency and renewables; and Business incubators for new renewable energy businesses and new product development The new MARET facility will support the mission of the US Department of Energy (DOE) Solar Program, “to improve America’s security, environmental quality, and economic prosperity through public-private partnerships that bring reliable and affordable solar energy technologies to the marketplace,” through a variety of educational and business assistance programs. Further, technical innovations planned for the MARET facility and its applied research activities will advance the Solar Program strategic goals to “reduce the cost of solar energy to the point it becomes competitive in relevant energy markets (e.g., buildings, power plants) and for solar technology to enable a sustainable solar industry.” Overarching Goals relative to program needs, future expansion, flexibility, quality of materials, and construction and operational costs:; Experimental: The structure and systems of the building operate as an educational resource. The systems are meant to be a source for data collection and study for building users and instructors; Educational: Part of the evolution of this building and its ongoing goals is to use the building as an educational tool, one where new ideas developed in the world and especially at Crowder can be tested further as part of MARET's curriculum; LEED Platinum: achieve highest level of LEED certification; Net Zero: The building will utilize existing wind and alternate energy sources on campus and add solar PVT panels and achieve as close as possible to a net zero energy usage; and Phase II: The phase II portion of this project will expand the Internet student area, additional classrooms, and labs, as well as an auditorium and exhibit area.« less
Usage of emergency medical services by children with special health care needs.
Suruda, A; Vernon, D D; Diller, E; Dean, J M
2000-01-01
To describe the usage of emergency medical services (EMS) by children with special health care needs (CSHCN). All EMS runs and related hospital records for children aged 0-17 years in Utah in 1991-92 were linked. The CSHCN status was determined from ICD-9 diagnoses using three available definitions. The amounts of EMS usage were compared between CSHCN and other children. A pediatric intensive care practitioner determined CSHCN status by chart review for 915 children transported by EMS to a pediatric tertiary care hospital, and his classification was compared with the CSHCN status assigned by the three ICD-9-based definitions. The three definitions assigned CSHCN status for 2% to 24% of children using EMS. When compared with other children, CSHCN were more likely to be admitted to the hospital, more likely to use EMS for transfer between health care facilities, and more likely to receive prehospital procedures such as intravenous therapy. In the group of children whose charts were reviewed individually, one ICD-9-based definition most closely agreed to determination of CSHCN status by a pediatric intensive care practitioner. Children with special health care needs who use EMS are more likely to receive advanced life support service, to receive prehospital procedures, and to be transferred from one health care facility to another. There is need for a specific and measurable definition of CSHCN that can be applied to existing health data.
Stagich, Brooke H; Moore, Kelsey R; Newton, Joseph R; Dixon, Kenneth L; Jannik, G Timothy
2017-04-01
Most U.S. Department of Energy (DOE) facilities with radiological airborne releases use the U.S. Environmental Protection Agency's (EPA) environmental dosimetry code CAP88-PC to demonstrate compliance with regulations in 40CFR61, subpart H [National Emission Standards for Hazardous Air Pollutants: Radiological (NESHAP)]. In 2015, EPA released Version 4 of CAP88-PC, which included significant modifications that improved usability and age-dependent dose coefficients and usage factors for six age groups (infant, 1 y, 5 y, 10 y, 15 y, and adult). However, EPA has not yet provided specific guidance on how to use these age-dependent factors. For demonstrating compliance with DOE public dose regulations, the Savannah River Site (SRS) recently changed from using the maximally exposed individual (MEI) concept (adult male) to the representative person concept (age- and gender-averaged reference person). In this study, dose comparisons are provided between the MEI and a SRS-specific representative person using the age-specific dose coefficients and usage factors in CAP88-PC V.4. Dose comparisons also are provided for each of the six age groups using five radionuclides of interest at SRS (tritium oxide, Cs, Sr, Pu, and I). In general, the total effective dose increases about 11% for the representative person as compared to the current NESHAP MEI because of the inclusion of the more radiosensitive age groups.
Takata, Miki; Fukushima, Kazuyo; Kino-Kimata, Noriko; Nagao, Norio; Niwa, Chiaki; Toda, Tatsuki
2012-08-15
In Japan, a revised Food Recycling Law went into effect in 2007 to promote a "recycling loop" that requires food industries to purchase farm products that are grown using food waste-derived compost/animal feed. To realize and expand food recycling, it is necessary to evaluate how the recycling facilities work in the recycling loop. The purpose of this study is to assess the environmental and economic efficiency of the food recycling facilities that are involved in the recycling loop, which are also known as looped facilities. The global warming potential and running cost of five looped facilities were evaluated by LCA (life cycle assessment) and LCC (life cycle cost) approaches: machine integrated compost, windrow compost, liquid feed, dry feed, and bio-gasification. The LCA results showed low total GHG (greenhouse gas) emissions of -126 and -49 kg-CO(2)/t-waste, respectively, for dry feed and bio-gasification facilities, due to a high substitution effect. The LCC study showed a low running cost for composting facilities of -15,648 and -18,955 yen/t-waste, respectively, due to high revenue from the food waste collection. It was found that the mandatory reporting of food waste emitters to the government increased collection fees; however, the collection fee in animal feed facilities was relatively low because food waste was collected at a low price or nutritious food waste was purchased to produce quality feed. In the characterisation survey of various treatment methods, the composting facilities showed a relatively low environmental impact and a high economic efficiency. Animal feed facilities had a wide distribution of the total GHG emissions, depending on both the energy usage during the drying process and the substitution effect, which were related to the water content of the food waste and the number of recycled products. In comparison with incineration, the majority of the food recycling facilities showed low GHG emissions and economic effectiveness. This paper also reported on the effects of recycling loops by comparing looped and non-looped animal feed facilities, and confirmed that the looped facilities were economically effective, due to an increased amount of food waste collection. Copyright © 2012 Elsevier B.V. All rights reserved.
Energy usage while maintaining thermal comfort: A case study of a UNT dormitory
NASA Astrophysics Data System (ADS)
Gambrell, Dusten
Campus dormitories for the University of North Texas house over 5500 students per year; each one of them requires certain comfortable living conditions while they live there. There is an inherit amount of money required in order to achieve minimal comfort levels; the cost is mostly natural gas for water and room heating and electricity for cooling, lighting and peripherals. The US Department of Energy has developed several programs to aid in performing energy simulations to help those interested design more cost effective building designs. Energy-10 is such a program that allows users to conduct whole house evaluations by reviewing and altering a few parameters such as building materials, solar heating, energy efficient windows etc. The idea of this project was to recreate a campus dormitory and try to emulate existent energy consumption then try to find ways of lowering that usage while maintaining a high level of personal comfort.
DOT National Transportation Integrated Search
1988-01-01
This study was conducted to examine existing conditions at Virginia's interstate rest areas and welcome centers and to assess what impact additional services, such as vending machines, might have on the service delivery of these facilities. A selecte...
Sudiajeng, Lilik; Adiputra, Nyoman; Leibbrandt, Richard
2012-12-01
This research was conducted to assess the positive effect of the ergonomics work station on the health impairment and electrical energy usage at the woodworking workshop in Bali, Indonesia. Woodworking workshops are dangerous, particularly when they are used improperly. Workers are exposed to health hazards that cause health impairment and inefficiencies in their work conditions. A preliminary study at a woodworking workshop at the Bali State Polytechnic showed that the work station was not suitable to body size of the participants and caused awkward postures. In addition, there was also an inappropriate physical work environment. Both inappropriate work station and physical work environment caused participants to be less active and motivated. This paper reports on an experimental study into the effects of an ergonomic intervention at this workshop. The participants were 2 groups of male students with 10 participants in each group. The first group performed the task with the original work station as a control group, while the second group performed the task with the new work station. The study found a significant difference between groups (p < 0.05) both for the health impairment and the electrical energy usage. The ergonomics intervention on the work station decreased the working heart rate (16.7%), the total score of musculoskeletal disorders (17.3%), and the total score of psychological fatigue (21.5%). Furthermore, it also decreased the electrical energy usage (38.7%). This shows that an ergonomics intervention on work station decreased the health impairment and saved electrical energy usage. It also protected the workers from woodworking hazards and allowed participants to perform their tasks in healthy, safe, convenient and efficient work conditions.
Accurate Energy Transaction Allocation using Path Integration and Interpolation
NASA Astrophysics Data System (ADS)
Bhide, Mandar Mohan
This thesis investigates many of the popular cost allocation methods which are based on actual usage of the transmission network. The Energy Transaction Allocation (ETA) method originally proposed by A.Fradi, S.Brigonne and B.Wollenberg which gives unique advantage of accurately allocating the transmission network usage is discussed subsequently. Modified calculation of ETA based on simple interpolation technique is then proposed. The proposed methodology not only increase the accuracy of calculation but also decreases number of calculations to less than half of the number of calculations required in original ETAs.
Equipment and Energy Usage in a Large Teaching Hospital in Norway.
Rohde, Tarald; Martinez, Robert
2015-01-01
This article presents a study of how equipment is used in a Norwegian University hospital and suggests ways to reduce hospital energy consumption. Analysis of energy data from Norway's newest teaching hospital showed that electricity consumption was up to 50% of the whole-building energy consumption. Much of this is due to the increasing energy intensity of hospital-specific equipment. Measured power and reported usage patterns for equipment in the studied departments show daytime energy intensity of equipment at about 28.5 kBTU/ft2 per year (90 kWh/m2 per year), compared to building code standard value of only 14.9 kBTU/ft2 (47 kWh/m2 per year) for hospitals. This article intends to fill gaps in our understanding of how users and their equipment affect the energy balance in hospitals and suggests ways in which designers and equipment suppliers can help optimize energy performance while maintaining quality in the delivery of health services.
Reconsidering access: park facilities and neighborhood disamenities in New York City.
Weiss, Christopher C; Purciel, Marnie; Bader, Michael; Quinn, James W; Lovasi, Gina; Neckerman, Kathryn M; Rundle, Andrew G
2011-04-01
With increasing concern about rising rates of obesity, public health researchers have begun to examine the availability of parks and other spaces for physical activity, particularly in cities, to assess whether access to parks reduces the risk of obesity. Much of the research in this field has shown that proximity to parks may support increased physical activity in urban environments; however, as yet, there has been limited consideration of environmental impediments or disamenities that might influence individuals' perceptions or usage of public recreation opportunities. Prior research suggests that neighborhood disamenities, for instance crime, pedestrian safety, and noxious land uses, might dissuade people from using parks or recreational facilities and vary by neighborhood composition. Motivated by such research, this study estimates the relationship between neighborhood compositional characteristics and measures of park facilities, controlling for variation in neighborhood disamenities, using geographic information systems (GIS) data for New York City parks and employing both kernel density estimation and distance measures. The central finding is that attention to neighborhood disamenities can appreciably alter the relationship between neighborhood composition and spatial access to parks. Policy efforts to enhance the recreational opportunities in urban areas should expand beyond a focus on availability to consider also the hazards and disincentives that may influence park usage.
Chang, Carolyn T.; Colicino, Erica G.; DiPaola, Elizabeth J.; Al-Hasnawi, Hadi Jabbar; Whipps, Christopher M.
2016-01-01
Mycobacteriosis is a bacterial disease that is common in captive, wild and research fish. There is no one causative agent of mycobacteriosis, as several strains and species of Mycobacterium have been identified in zebrafish. With increased usage and investment in wild-type and mutant zebrafish strains, considerable value is placed on preserving zebrafish health. One control measure used to prevent mycobacterial spread within and between zebrafish facilities is egg disinfection. Here we investigate the effectiveness of three disinfectants [chlorine bleach, hydrogen peroxide, and povidone iodine (PVPI)] commonly included in egg disinfection protocols for laboratory fish as well as aquaculture fish and compare the knockdown effect of these treatments on Mycobacterium spp. in vitro. Despite current usage, comparison of these disinfection regimes’ abilities to prevent mycobacterial growth has not been tested. We found that the germicidal effect of different disinfectants vary by Mycobacterium spp.. Hydrogen peroxide was the least effective disinfectant, followed by unbuffered chlorine bleach, which is commonly used to disinfect embryos in zebrafish facilities. Disinfection with 25 ppm PVPI for 5 min was very effective, and may be an improved alternative to chlorine bleach for embryo disinfection. Results from this study can be utilized by laboratory fish facilities in order to prevent the spread of mycobacteriosis in research fish. PMID:26423444
Optimal control of Formula One car energy recovery systems
NASA Astrophysics Data System (ADS)
Limebeer, D. J. N.; Perantoni, G.; Rao, A. V.
2014-10-01
The utility of orthogonal collocation methods in the solution of optimal control problems relating to Formula One racing is demonstrated. These methods can be used to optimise driver controls such as the steering, braking and throttle usage, and to optimise vehicle parameters such as the aerodynamic down force and mass distributions. Of particular interest is the optimal usage of energy recovery systems (ERSs). Contemporary kinetic energy recovery systems are studied and compared with future hybrid kinetic and thermal/heat ERSs known as ERS-K and ERS-H, respectively. It is demonstrated that these systems, when properly controlled, can produce contemporary lap time using approximately two-thirds of the fuel required by earlier generation (2013 and prior) vehicles.
Experimental investigation on AC unit integrated with sensible heat storage (SHS)
NASA Astrophysics Data System (ADS)
Aziz, N. A.; Amin, N. A. M.; Majid, M. S. A.; Hussin, A.; Zhubir, S.
2017-10-01
The growth in population and economy has increases the energy demand and raises the concerns over the sustainable energy source. Towards the sustainable development, energy efficiency in buildings has become a prime objective. In this paper, the integration of thermal energy storage was studied. This paper presents an experimental investigation on the performance of an air conditioning unit integrated with sensible heat storage (SHS) system. The results were compared to the conventional AC systems in the terms of average electricity usage, indoor temperature and the relative humidity inside the experimented room (cabin container). Results show that the integration of water tank as an SHS reduces the electricity usage by 5%, while the integration of well-insulated water tank saves up to 8% of the electricity consumption.
Educational Specifications, New Caney Independent School District.
ERIC Educational Resources Information Center
Houston Univ., TX. Bureau of Educational Research and Services.
A year-long study of the communities encompassed by the New Caney Independent School District in Montgomery County, Texas, was conducted by the College of Education at the University of Houston. Educational facilities and program were surveyed. Planning data included--description of district, land usage, pupil residence, population density and…
Recommendations to Improve Space Projection Models and University Space Usage
ERIC Educational Resources Information Center
Stigall, Sam W.
2007-01-01
In today"s economy, public university administrators need to reflect on current practices for reporting and projecting space requirements to government entities as the cost of constructing new facilities or renovating space rises while income from legislative appropriations diminishes. As stewards of public buildings and funds, institutions…
WINDS: A Web-Based Intelligent Interactive Course on Data-Structures
ERIC Educational Resources Information Center
Sirohi, Vijayalaxmi
2007-01-01
The Internet has opened new ways of learning and has brought several advantages to computer-aided education. Global access, self-paced learning, asynchronous teaching, interactivity, and multimedia usage are some of these. Along with the advantages comes the challenge of designing the software using the available facilities. Integrating online…
Improve Carpet Life with Proper Installation.
ERIC Educational Resources Information Center
Grogan, Ralph
1998-01-01
Provides guidance on ways to extend carpet life in educational facilities by paying attention to the details of carpeting installation. Issues to consider include choosing carpeting to meet specific usage requirements, are fiber protectorants used, is the installation properly done by qualified installers, and is moisture testing done prior to…
Laundry Facility Considerations: Tips on an Often Overlooked Student Housing Issue.
ERIC Educational Resources Information Center
Reynolds, Rick
1991-01-01
Administrators making long-term decisions on campus laundry equipment and service need to consider self-ownership versus contracting. Considerations in selecting a contractor include the contract, accountability, repair services, and machine usage pricing. Laundry rooms should not be located where they pose security problems and should be arranged…
77 FR 27790 - Federal Property Suitable as Facilities To Assist the Homeless
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-11
... conditions; sf. varies; usage varies; needs extensive repairs Kentucky 5 Bldgs. Blue Grass Army Depot... Grass Army Depot Richmond KY 40475 Landholding Agency: Army Property Number: 21201220046 Status... E0450-0457 & E0459 Blue Grass Army Depot Richmond KY 40475 Landholding Agency: Army Property Number...
Balancing Your Database Network Licenses against Your Budget.
ERIC Educational Resources Information Center
Bauer, Benjamin F.
1995-01-01
Discussion of choosing database access to satisfy users and budgetary constraints highlights a method to make educated estimates of simultaneous usage levels. Topics include pricing; advances in networks and CD-ROM technology; and two networking scenarios, one in an academic library and one in a corporate research facility. (LRW)
40 CFR 63.10430 - What notifications must I submit and by when?
Code of Federal Regulations, 2010 CFR
2010-07-01
... CATEGORIES (CONTINUED) National Emission Standards for Hospital Ethylene Oxide Sterilizers Notifications... the number of ethylene oxide sterilizers, the size (volume) of each, the number of aeration units, if any, the amount of annual ethylene oxide usage at the facility, the control technique used for each...
Take a Tour of Our Facility | Energy Systems Integration Facility | NREL
Take a Tour of Our Facility Take a Tour of Our Facility The Energy Systems Integration Facility Optical Characterization Laboratory System Performance Laboratory Power Systems Integration Laboratory Control Room Energy Storage Laboratory Outdoor Testing Areas Outdoor Testing Areas Energy Systems
77 FR 23373 - Small Business Investment Companies-Energy Saving Qualified Investments
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-19
... Debenture usage, number of Small Businesses financed, resulting breakthroughs in technology, comparative studies quantifying energy savings, and performance of Small Businesses financed. While SBA is concerned...
Kilowatt Counter: A Consumer's Guide to Energy Concepts, Quantities, and Uses.
ERIC Educational Resources Information Center
Friend, Gil; Morris, David
This booklet is a basic introduction to energy and energy usage. The first chapter discusses various forms of energy and how they are measured and converted from one to another with a unit conversion chart included. Tables and figures list annual energy requirements of household electrical appliances and energy requirements for houses with various…
Advanced human-machine interface for collaborative building control
Zheng, Xianjun S.; Song, Zhen; Chen, Yanzi; Zhang, Shaopeng; Lu, Yan
2015-08-11
A system for collaborative energy management and control in a building, including an energy management controller, one or more occupant HMIs that supports two-way communication between building occupants and a facility manager, and between building occupants and the energy management controller, and a facility manager HMI that supports two-way communication between the facility manager and the building occupants, and between the facility manager and the energy management controller, in which the occupant HMI allows building occupants to provide temperature preferences to the facility manager and the energy management controller, and the facility manager HMI allows the facility manager to configure an energy policy for the building as a set of rules and to view occupants' aggregated temperature preferences, and the energy management controller determines an optimum temperature range that resolves conflicting occupant temperature preferences and occupant temperature preferences that conflict with the facility manager's energy policy for the building.
18 CFR 292.205 - Criteria for qualifying cogeneration facilities.
Code of Federal Regulations, 2010 CFR
2010-04-01
... standard. For any topping-cycle cogeneration facility, the useful thermal energy output of the facility... thermal energy output, during the 12-month period beginning with the date the facility first produces... total energy input of natural gas and oil to the facility; or (B) If the useful thermal energy output is...
2017-10-26
1 FINAL REPORT Converting Constant Volume, Multizone Air Handling Systems to Energy Efficient Variable Air Volume Multizone...Systems Energy and Water Projects Project Number: EW-201152 ERDC-CERL 26 October 2017 2 TABLE OF CONTENTS ACKNOWLEDGEMENTS...16 3.2.1 Energy Usage (Quantitative
Schools Find Answers to the Energy Crunch.
ERIC Educational Resources Information Center
Wall, Roger
1981-01-01
Highlights two schools that have reduced their energy usage, one through such methods as weatherization and solar water collectors, and the other through switching from burning oil to burning wood pellets. (JM)
Lean energy analysis of CNC lathe
NASA Astrophysics Data System (ADS)
Liana, N. A.; Amsyar, N.; Hilmy, I.; Yusof, MD
2018-01-01
The industrial sector in Malaysia is one of the main sectors that have high percentage of energy demand compared to other sector and this problem may lead to the future power shortage and increasing the production cost of a company. Suitable initiatives should be implemented by the industrial sectors to solve the issues such as by improving the machining system. In the past, the majority of the energy consumption in industry focus on lighting, HVAC and office section usage. Future trend, manufacturing process is also considered to be included in the energy analysis. A study on Lean Energy Analysis in a machining process is presented. Improving the energy efficiency in a lathe machine by enhancing the cutting parameters of turning process is discussed. Energy consumption of a lathe machine was analyzed in order to identify the effect of cutting parameters towards energy consumption. It was found that the combination of parameters for third run (spindle speed: 1065 rpm, depth of cut: 1.5 mm, feed rate: 0.3 mm/rev) was the most preferred and ideal to be used during the turning machining process as it consumed less energy usage.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Drewmark Communications; Sartor, Dale; Wilson, Mark
2010-07-01
High-performance computing facilities in the United States consume an enormous amount of electricity, cutting into research budgets and challenging public- and private-sector efforts to reduce energy consumption and meet environmental goals. However, these facilities can greatly reduce their energy demand through energy-efficient design of the facility itself. Using a case study of a facility under design, this article discusses strategies and technologies that can be used to help achieve energy reductions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Piette, Mary Ann; Sezgen, Osman; Watson, David S.
This report describes the results of a research project to develop and evaluate the performance of new Automated Demand Response (Auto-DR) hardware and software technology in large facilities. Demand Response (DR) is a set of activities to reduce or shift electricity use to improve electric grid reliability, manage electricity costs, and ensure that customers receive signals that encourage load reduction during times when the electric grid is near its capacity. The two main drivers for widespread demand responsiveness are the prevention of future electricity crises and the reduction of electricity prices. Additional goals for price responsiveness include equity through costmore » of service pricing, and customer control of electricity usage and bills. The technology developed and evaluated in this report could be used to support numerous forms of DR programs and tariffs. For the purpose of this report, we have defined three levels of Demand Response automation. Manual Demand Response involves manually turning off lights or equipment; this can be a labor-intensive approach. Semi-Automated Response involves the use of building energy management control systems for load shedding, where a preprogrammed load shedding strategy is initiated by facilities staff. Fully-Automated Demand Response is initiated at a building or facility through receipt of an external communications signal--facility staff set up a pre-programmed load shedding strategy which is automatically initiated by the system without the need for human intervention. We have defined this approach to be Auto-DR. An important concept in Auto-DR is that a facility manager is able to ''opt out'' or ''override'' an individual DR event if it occurs at a time when the reduction in end-use services is not desirable. This project sought to improve the feasibility and nature of Auto-DR strategies in large facilities. The research focused on technology development, testing, characterization, and evaluation relating to Auto-DR. This evaluation also included the related decisionmaking perspectives of the facility owners and managers. Another goal of this project was to develop and test a real-time signal for automated demand response that provided a common communication infrastructure for diverse facilities. The six facilities recruited for this project were selected from the facilities that received CEC funds for new DR technology during California's 2000-2001 electricity crises (AB970 and SB-5X).« less
Energy Tracking in Classrooms - A Real Time Experiment with Grade 5 Students
NASA Astrophysics Data System (ADS)
Lam, H. M.; Ho, F.
2015-12-01
ISF Academy, a K-G12 school in Hong Kong with over 1500 students and currently spanning 3 buildings, is retrofitting the school with an energy tracking system in three phases. The first phase during the fall of 2015 will include retrofitting eight Grade 5 classrooms. This new program will show the daily energy usage data from these classrooms. The Grade 5 students receive feedback on their energy use in real time as they compete over two months in their homeroom classes to lower their electrical use, and subsequently their carbon footprint. This competition style initiative will teach the 180 Grade 5 students about their energy usage in a fun and informative manner. ISF Academy has over 400 air-conditioners and we have already determined that the air conditioners are the largest single use of energy in the school. The energy tracking system installed and maintained by from Global Design Corporation utilizes uniquely identified current detectors attached to circuit breakers, to monitor electrical use of individual circuits. These detectors will also monitor the energy used for classroom lighting, fans and plugs, as well as the air conditioners. The system has been installed and the Grade 5 classrooms averaged between 40 kWh and 120 kWh of usage in May 2015. This data will be used as the baseline for the competition. Further analysis can also be done with the data, such as calculating the carbon emissions reduction throughout the school year, providing possible class learning activities and also aiding in future energy use and carbon footprint predictions. The data collected will help refine phase 2 and 3 of the installation, expanding the system to more buildings and also giving insight to the rollout of the system to the whole school when the systems are fully in place.
Modeling Battery Behavior on Sensory Operations for Context-Aware Smartphone Sensing
Yurur, Ozgur; Liu, Chi Harold; Moreno, Wilfrido
2015-01-01
Energy consumption is a major concern in context-aware smartphone sensing. This paper first studies mobile device-based battery modeling, which adopts the kinetic battery model (KiBaM), under the scope of battery non-linearities with respect to variant loads. Second, this paper models the energy consumption behavior of accelerometers analytically and then provides extensive simulation results and a smartphone application to examine the proposed sensor model. Third, a Markov reward process is integrated to create energy consumption profiles, linking with sensory operations and their effects on battery non-linearity. Energy consumption profiles consist of different pairs of duty cycles and sampling frequencies during sensory operations. Furthermore, the total energy cost by each profile is represented by an accumulated reward in this process. Finally, three different methods are proposed on the evolution of the reward process, to present the linkage between different usage patterns on the accelerometer sensor through a smartphone application and the battery behavior. By doing this, this paper aims at achieving a fine efficiency in power consumption caused by sensory operations, while maintaining the accuracy of smartphone applications based on sensor usages. More importantly, this study intends that modeling the battery non-linearities together with investigating the effects of different usage patterns in sensory operations in terms of the power consumption and the battery discharge may lead to discovering optimal energy reduction strategies to extend the battery lifetime and help a continual improvement in context-aware mobile services. PMID:26016916
Modeling battery behavior on sensory operations for context-aware smartphone sensing.
Yurur, Ozgur; Liu, Chi Harold; Moreno, Wilfrido
2015-05-26
Energy consumption is a major concern in context-aware smartphone sensing. This paper first studies mobile device-based battery modeling, which adopts the kinetic battery model (KiBaM), under the scope of battery non-linearities with respect to variant loads. Second, this paper models the energy consumption behavior of accelerometers analytically and then provides extensive simulation results and a smartphone application to examine the proposed sensor model. Third, a Markov reward process is integrated to create energy consumption profiles, linking with sensory operations and their effects on battery non-linearity. Energy consumption profiles consist of different pairs of duty cycles and sampling frequencies during sensory operations. Furthermore, the total energy cost by each profile is represented by an accumulated reward in this process. Finally, three different methods are proposed on the evolution of the reward process, to present the linkage between different usage patterns on the accelerometer sensor through a smartphone application and the battery behavior. By doing this, this paper aims at achieving a fine efficiency in power consumption caused by sensory operations, while maintaining the accuracy of smartphone applications based on sensor usages. More importantly, this study intends that modeling the battery non-linearities together with investigating the effects of different usage patterns in sensory operations in terms of the power consumption and the battery discharge may lead to discovering optimal energy reduction strategies to extend the battery lifetime and help a continual improvement in context-aware mobile services.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aziz, Azizan; Lasternas, Bertrand; Alschuler, Elena
The American Recovery and Reinvestment Act stimulus funding of 2009 for smart grid projects resulted in the tripling of smart meters deployment. In 2012, the Green Button initiative provided utility customers with access to their real-time1 energy usage. The availability of finely granular data provides an enormous potential for energy data analytics and energy benchmarking. The sheer volume of time-series utility data from a large number of buildings also poses challenges in data collection, quality control, and database management for rigorous and meaningful analyses. In this paper, we will describe a building portfolio-level data analytics tool for operational optimization, businessmore » investment and policy assessment using 15-minute to monthly intervals utility data. The analytics tool is developed on top of the U.S. Department of Energy’s Standard Energy Efficiency Data (SEED) platform, an open source software application that manages energy performance data of large groups of buildings. To support the significantly large volume of granular interval data, we integrated a parallel time-series database to the existing relational database. The time-series database improves on the current utility data input, focusing on real-time data collection, storage, analytics and data quality control. The fully integrated data platform supports APIs for utility apps development by third party software developers. These apps will provide actionable intelligence for building owners and facilities managers. Unlike a commercial system, this platform is an open source platform funded by the U.S. Government, accessible to the public, researchers and other developers, to support initiatives in reducing building energy consumption.« less
Energy Theft in the Advanced Metering Infrastructure
NASA Astrophysics Data System (ADS)
McLaughlin, Stephen; Podkuiko, Dmitry; McDaniel, Patrick
Global energy generation and delivery systems are transitioning to a new computerized "smart grid". One of the principle components of the smart grid is an advanced metering infrastructure (AMI). AMI replaces the analog meters with computerized systems that report usage over digital communication interfaces, e.g., phone lines. However, with this infrastructure comes new risk. In this paper, we consider adversary means of defrauding the electrical grid by manipulating AMI systems. We document the methods adversaries will use to attempt to manipulate energy usage data, and validate the viability of these attacks by performing penetration testing on commodity devices. Through these activities, we demonstrate that not only is theft still possible in AMI systems, but that current AMI devices introduce a myriad of new vectors for achieving it.
Energy for Survival: The Alternative to Extinction.
ERIC Educational Resources Information Center
Clark, Wilson
The author initially describes the basic physical principles associated with energy and the rise of energy usage in the United States. Also discussed are the ways energy limits growth and its use in various sectors of society. It is suggested that the decentralization of America's electrical system will save a great deal of energy. A variety of…
HOOPER BAY HOUSING ANALYSIS AND ENERGY FEASIBILITY REPORT
DOE Office of Scientific and Technical Information (OSTI.GOV)
SEA LION CORPORATION; COLD CLIMATE HOUSING RESEARCH CENTER; SOLUTIONS FOR HEALTHY BREATHING
2012-12-30
Sea Lion applied for and received a grant from the Department of Energy (DOE) towards this end titled Energy Efficiency Development and Deployment in Indian Country. The initial objectives of the Hooper Bay Energy Efficiency Feasibility Study were to demonstrate a 30% reduction in residential/commercial energy usage and identify the economic benefits of implementing energy efficiency measures to the Tribe through: (1) partnering with Whitney Construction and Solutions for Healthy Breathing in the training and hire of 2 local energy assessors to conduct energy audits of 9 representative housing models and 2 commercial units in the community. These homes aremore » representative of 52 homes constructed across different eras. (2) partnering with Cold Climate Housing Research Center to document current electrical and heating energy consumption and analyze data for a final feasibility report (3) assessing the economics of electricity & heating fuel usage; (4) projecting energy savings or fossil fuel reduction by modeling of improvement scenarios and cost feasibility The following two objectives will be completed after the publication of this report: (5) the development of materials lists for energy efficiency improvements (6) identifying financing options for the follow-up energy efficiency implementation phase.« less
Career Field Experience: A Look at On-site Usage by High School Communication Class.
ERIC Educational Resources Information Center
Kaye, Thomas
The career field experience program at a midwestern high school places broadcasting students on location for observation of the profession and optional job training or work. In addition to radio and television stations, field locations include advertising agencies with production studios, corporate production facilities, recording studios, cable…
Evaluation of Visual Computer Simulator for Computer Architecture Education
ERIC Educational Resources Information Center
Imai, Yoshiro; Imai, Masatoshi; Moritoh, Yoshio
2013-01-01
This paper presents trial evaluation of a visual computer simulator in 2009-2011, which has been developed to play some roles of both instruction facility and learning tool simultaneously. And it illustrates an example of Computer Architecture education for University students and usage of e-Learning tool for Assembly Programming in order to…
STS-118 Astronaut Tracy Caldwell During Training
NASA Technical Reports Server (NTRS)
2006-01-01
Tracy E. Caldwell, STS-118 astronaut and mission specialist, participates in a training session on the usage of a special device, used to lower oneself from a troubled shuttle, in the Space Vehicle Mockup Facility at the Johnson Space Center. Caldwell is wearing a training version of her shuttle launch and entry suit.
77 FR 72335 - Submission for OMB Review; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-05
... and Uses: To collect facility usage data to prepare monthly metrics and data management reports; to... should be sent to Ms. Seehra at the Office of Management and Budget, Desk Officer for DoD, Room 10236.../ESD/Information Management Division, 4800 Mark Center Drive, East Tower, Suite 02G09, Alexandria, VA...
2009-10-20
Low usage volume raised concerns about the effectiveness of TOL. In 2004, the eHealth Division of TMA Information Management conducted a study to...Case Study 31 (Version 15.8). Falls Church, VA: Department of Defense, TRICARE Management Activity, Information Management eHealth Division
Mobile Phone Usage and its Health Effects Among Adults in a Semi-Urban Area of Southern India
Abraham, Sherin Billy; Kanimozhy, K.; Prasad, R. Vishnu; Singh, Zile; Purty, Anil J.
2016-01-01
Introduction Worldwide, mobile phone usage has been increased dramatically which could affect the health of the people. India has the second largest number of mobile phone users. However there are only few studies conducted in India to assess its effects on health. Aim To determine the prevalence and pattern of mobile phone usage and to assess the relationship between certain selected health problems and mobile phone usage among adults. Settings and Design Community-based cross-sectional study was conducted in Kottakuppam, a town panchayat in Villupuram district of Coastal Tamil Nadu, Southern India. It is a semi-urban area with a population of about 16,000. Majority of the residents are Muslim by religion and belong to different socio economic status. Materials and Methods The study was approved by the Institutional Ethics Committee. A total of 2121 study participants were interviewed by the pre-final medical students through house-to-house survey using a pretested structured questionnaire. The questionnaire included the variables such as socio demographic profile, mobile phone usage and pattern, selected health problems, perceived benefits and threats and blood pressure. Selected health problems included headache, earache, neck pain, tinnitus, painful fingers, restlessness, morning tiredness, tingling fingers, fatigue, eye symptoms, sleep disturbance and hypertension. Statistical Analysis Used Only 2054 were included for data analysis using SPSS 17 version. Proportions were calculated. Chi-square test was used to measure the p-value. The p-value < 0.05 was considered as statistically significant. Results The prevalence of mobile phone usage was 70%. Calling facility (94.2%) was used more than the SMS (67.6%). Health problems like headache, earache, tinnitus, painful fingers and restlessness etc., were found to be positively associated with mobile phone usage. There was negative association between hypertension and mobile phone usage. Conclusion The prevalence of mobile phone usage was high. There was significant association between selected health problems and mobile phone usage. In future, higher studies are required to confirm our findings. PMID:26894095
Elastic extension of a local analysis facility on external clouds for the LHC experiments
NASA Astrophysics Data System (ADS)
Ciaschini, V.; Codispoti, G.; Rinaldi, L.; Aiftimiei, D. C.; Bonacorsi, D.; Calligola, P.; Dal Pra, S.; De Girolamo, D.; Di Maria, R.; Grandi, C.; Michelotto, D.; Panella, M.; Taneja, S.; Semeria, F.
2017-10-01
The computing infrastructures serving the LHC experiments have been designed to cope at most with the average amount of data recorded. The usage peaks, as already observed in Run-I, may however originate large backlogs, thus delaying the completion of the data reconstruction and ultimately the data availability for physics analysis. In order to cope with the production peaks, the LHC experiments are exploring the opportunity to access Cloud resources provided by external partners or commercial providers. In this work we present the proof of concept of the elastic extension of a local analysis facility, specifically the Bologna Tier-3 Grid site, for the LHC experiments hosted at the site, on an external OpenStack infrastructure. We focus on the Cloud Bursting of the Grid site using DynFarm, a newly designed tool that allows the dynamic registration of new worker nodes to LSF. In this approach, the dynamically added worker nodes instantiated on an OpenStack infrastructure are transparently accessed by the LHC Grid tools and at the same time they serve as an extension of the farm for the local usage.
Energy Saving and GHG Emission Reduction in a Micro-CCHP System by Use of Solar Energy
NASA Astrophysics Data System (ADS)
Ion, Ion V.; Ciocea, Gheorghe; Popescu, Florin
2012-12-01
In this work, the reduction of greenhouse gas emission, and the energy saving by integrating solar collectors and photovoltaic panels in a Stirling engine based microcombined cooling, heating and power (mCCHP) system are studied. The mCCHP system consists of a natural gas Stirling CHP and an adsorber chiller. When the thermal outputs of the Stirling CHP and solar collectors are not sufficient to cover the heat demand for domestic hot water (DHW), heating/cooling, an auxiliary heating boiler starts to operate. The energy saving by using solar energy varies from 13.35% in December to 59.62% in April, in the case of solar collectors usage and from 7.47% in December to 28.27% in July, in the case of photovoltaic panels usage. By using solar energy the annual GHG emission decreases by 31.98% and the fuel cost reduction varies from 12.73% in December to 49.78% in June.
2012 Commercial Buildings Energy Consumption Survey: Energy Usage Summary
2016-01-01
EIA has released summary tables providing energy consumption estimates from the 2012 CBECS. The data show that despite a 14% increase in total buildings and a 22% increase in total floorspace since 2003, energy use in the estimated 5.6 million U.S. commercial buildings was up just 7% during the same period.
Energy management: total program considers all building's systems.
Blan, G J; Browne, K H
1978-09-16
Managing energy consumption, containing fuel usage, and preparing for alternate fuel sources are immediate areas for concern and action for all health care providers. The authors describe how they are meeting the challenge of increased energy costs and reduced availability while maintaining high-quality care by applying the concept of total energy management.
Student Use of Energy Concepts from Physics in Chemistry Courses
ERIC Educational Resources Information Center
Nagel, Megan L.; Lindsey, Beth A.
2015-01-01
This paper describes an interdisciplinary investigation of students' usage of ideas about energy from physics in the context of introductory chemistry. We focus on student understanding of the idea that potential energy is a function of distance between interacting objects, a concept relevant to understanding potential energy in both physical and…
Energy and Educational Facilities: Costs and Conservation.
ERIC Educational Resources Information Center
Educational Facilities Labs., Inc., New York, NY.
An analysis of energy costs and conservation in educational facilities in the United States is presented in this report. Tables and text give dollar figures for energy expenditures in education since the first oil embargo. Energy conservation through facilities management and through facilities modification is stressed. Recommendations are…
15 CFR 923.13 - Energy facility planning process.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 15 Commerce and Foreign Trade 3 2010-01-01 2010-01-01 false Energy facility planning process. 923... RESOURCE MANAGEMENT COASTAL ZONE MANAGEMENT PROGRAM REGULATIONS Uses Subject to Management § 923.13 Energy facility planning process. The management program must contain a planning process for energy facilities...
15 CFR 923.13 - Energy facility planning process.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 15 Commerce and Foreign Trade 3 2012-01-01 2012-01-01 false Energy facility planning process. 923... RESOURCE MANAGEMENT COASTAL ZONE MANAGEMENT PROGRAM REGULATIONS Uses Subject to Management § 923.13 Energy facility planning process. The management program must contain a planning process for energy facilities...
15 CFR 923.13 - Energy facility planning process.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 15 Commerce and Foreign Trade 3 2013-01-01 2013-01-01 false Energy facility planning process. 923... RESOURCE MANAGEMENT COASTAL ZONE MANAGEMENT PROGRAM REGULATIONS Uses Subject to Management § 923.13 Energy facility planning process. The management program must contain a planning process for energy facilities...
15 CFR 923.13 - Energy facility planning process.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 15 Commerce and Foreign Trade 3 2011-01-01 2011-01-01 false Energy facility planning process. 923... RESOURCE MANAGEMENT COASTAL ZONE MANAGEMENT PROGRAM REGULATIONS Uses Subject to Management § 923.13 Energy facility planning process. The management program must contain a planning process for energy facilities...
15 CFR 923.13 - Energy facility planning process.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 15 Commerce and Foreign Trade 3 2014-01-01 2014-01-01 false Energy facility planning process. 923... RESOURCE MANAGEMENT COASTAL ZONE MANAGEMENT PROGRAM REGULATIONS Uses Subject to Management § 923.13 Energy facility planning process. The management program must contain a planning process for energy facilities...
Blanco, Jesús; García, Andrés; Morenas, Javier de Las
2018-06-09
Energy saving has become a major concern for the developed society of our days. This paper presents a Wireless Sensor and Actuator Network (WSAN) designed to provide support to an automatic intelligent system, based on the Internet of Things (IoT), which enables a responsible consumption of energy. The proposed overall system performs an efficient energetic management of devices, machines and processes, optimizing their operation to achieve a reduction in their overall energy usage at any given time. For this purpose, relevant data is collected from intelligent sensors, which are in-stalled at the required locations, as well as from the energy market through the Internet. This information is analysed to provide knowledge about energy utilization, and to improve efficiency. The system takes autonomous decisions automatically, based on the available information and the specific requirements in each case. The proposed system has been implanted and tested in a food factory. Results show a great optimization of energy efficiency and a substantial improvement on energy and costs savings.
Pilot retrofit test of refrigerant R-134a for GDSCC
NASA Technical Reports Server (NTRS)
Albus, J.; Brown, B.; Dungao, M.; Spencer, G.
1994-01-01
NASA has issued an interim policy requiring all of its Centers to eliminate consumption (purchase) of stratospheric ozone-depleting substances, including chlorofluorocarbons (CFC's), by 1995. Also, plans must be outlined for the eventual phase out of their usage. The greatest source of CFC consumption and usage at the Goldstone Deep Space Communications Complex is refrigerant R-12, which is used in many of the facility's air-conditioning systems. A pilot retrofit test shows that retrofitting R-12 air-conditioning systems with hydrofluorocarbon R-13a would be a workable means to comply with the R-12 portion of NASA's policy. Results indicate acceptable cost levels and nearly equivalent system performance.
Ragossnig, A M; Wartha, C; Pomberger, R
2009-11-01
A major challenge for modern waste management lies in a smart integration of waste-to-energy installations in local energy systems in such a way that the energy efficiency of the waste-to-energy plant is optimized and that the energy contained in the waste is, therefore, optimally utilized. The extent of integration of thermal waste treatment processes into regular energy supply systems plays a major role with regard to climate control. In this research, the specific waste management situation looked at scenarios aiming at maximizing the energy recovery from waste (i.e. actual scenario and waste-to-energy process with 75% energy efficiency [22.5% electricity, 52.5% heat]) yield greenhouse gas emission savings due to the fact that more greenhouse gas emissions are avoided in the energy sector than caused by the various waste treatment processes. Comparing dedicated waste-to-energy-systems based on the combined heat and power (CHP) process with concepts based on sole electricity production, the energy efficiency proves to be crucial with regard to climate control. This underlines the importance of choosing appropriate sites for waste-to-energy-plants. This research was looking at the effect with regard to the climate impact of various waste management scenarios that could be applied alternatively by a private waste management company in Austria. The research is, therefore, based on a specific set of data for the waste streams looked at (waste characteristics, logistics needed, etc.). Furthermore, the investigated scenarios have been defined based on the actual available alternatives with regard to the usage of treatment plants for this specific company. The standard scenarios for identifying climate impact implications due to energy recovery from waste are based on the respective marginal energy data for the power and heat generation facilities/industrial processes in Austria.
2012-06-16
Engineers to help identify and develop energy and water conservation projects in the facilities for which they are responsible. DISCLAIMER: The...and water throughout their facility. To identify energy and water conservation measures (ECMs), an energy manager would generally start by performing...an Energy and Water Conservation Assessment, essentially a facility-level evaluation of the en- ergy and water consuming equipment and systems that
Green, Tyler; Smith, Terry; Hodges, Richard; Fry, W Mark
2017-12-01
Record keeping within research animal care facilities is a key part of the guidelines set forth by national regulatory bodies and mandated by federal laws. Research facilities must maintain records of animal health issues, procedures and usage. Facilities are also required to maintain records regarding regular husbandry such as general animal checks, feeding and watering. The level of record keeping has the potential to generate excessive amounts of paper which must be retained in a fashion as to be accessible. In addition it is preferable not to retain within administrative areas any paper records which may have been in contact with animal rooms. Here, we present a flexible, simple and inexpensive process for the generation and storage of electronic animal husbandry records using smartphone technology over a WiFi or cellular network.
The Future of American Power: Energy and National Security
2010-02-17
8 What does it all mean ? .................................................................................................................. 11...renewable energy generation and usage within the United States. What does it all mean ? The United States must prepare for a future where the use of
Green Chemistry Challenge: 2017 Small Business Award
Green Chemistry Challenge 2017 award winner, UniEnergy,improved a vanadium redox flow battery to double the energy density, have a broader operating temperature range, a smaller footprint, reduced chemical usage, and very little capacity degradation.
10 CFR 451.4 - What is a qualified renewable energy facility.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 3 2013-01-01 2013-01-01 false What is a qualified renewable energy facility. 451.4 Section 451.4 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION RENEWABLE ENERGY PRODUCTION INCENTIVES § 451.4 What is a qualified renewable energy facility. In order to qualify for an incentive payment under...
10 CFR 451.4 - What is a qualified renewable energy facility.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 3 2010-01-01 2010-01-01 false What is a qualified renewable energy facility. 451.4 Section 451.4 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION RENEWABLE ENERGY PRODUCTION INCENTIVES § 451.4 What is a qualified renewable energy facility. In order to qualify for an incentive payment under...
10 CFR 451.4 - What is a qualified renewable energy facility.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 3 2011-01-01 2011-01-01 false What is a qualified renewable energy facility. 451.4 Section 451.4 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION RENEWABLE ENERGY PRODUCTION INCENTIVES § 451.4 What is a qualified renewable energy facility. In order to qualify for an incentive payment under...
10 CFR 451.4 - What is a qualified renewable energy facility.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 3 2014-01-01 2014-01-01 false What is a qualified renewable energy facility. 451.4 Section 451.4 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION RENEWABLE ENERGY PRODUCTION INCENTIVES § 451.4 What is a qualified renewable energy facility. In order to qualify for an incentive payment under...
10 CFR 451.4 - What is a qualified renewable energy facility.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 3 2012-01-01 2012-01-01 false What is a qualified renewable energy facility. 451.4 Section 451.4 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION RENEWABLE ENERGY PRODUCTION INCENTIVES § 451.4 What is a qualified renewable energy facility. In order to qualify for an incentive payment under...
18 CFR 292.204 - Criteria for qualifying small power production facilities.
Code of Federal Regulations, 2011 CFR
2011-04-01
... FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY REGULATIONS UNDER THE PUBLIC UTILITY REGULATORY... production capacity of any other small power production facilities that use the same energy resource, are... production facilities within one mile of such facilities. (b) Fuel use. (1)(i) The primary energy source of...
Automated management of radioactive sources in Saudi Arabia
NASA Astrophysics Data System (ADS)
Al-Kheliewi, Abdullah S.; Jamil, M. F.; Basar, M. R.; Tuwaili, W. R.
2014-09-01
For usage of radioactive substances, any facility has to register and take license from relevant authority of the country in which such facility is operating. In the Kingdom of Saudi Arabia (KSA), the authority for managing radioactive sources and providing licenses to organizations for its usage is the National Center of Radiation Protection (NCRP). This paper describes the system that automates registration and licensing process of the National Center of Radiation Protection. To provide 24×7 accesses to all the customers of NCRP, system is developed as web-based application that provide facility to online register, request license, renew license, check request status, view historical data and reports etc. and other features are provided as Electronic Services that would be accessible to users via internet. The system also was designed to streamline and optimize internal operations of NCRP besides providing ease of access to its customers by implementing a defined workflow through which every registration and license request will be routed. In addition to manual payment option, the system would also be integrated with SADAD (online payment system) that will avoid lengthy and cumbersome procedures associated with manual payment mechanism. Using SADAD payment option license fee could be paid through internet/ATM machine or branch of any designated bank, Payment will be instantly notified to NCRP hence delay in funds transfer and verification of invoice could be avoided, SADAD integration is discussed later in the document.
Energy Systems Integration Facility (ESIF) Facility Stewardship Plan: Revision 2.1
DOE Office of Scientific and Technical Information (OSTI.GOV)
Torres, Juan; Anderson, Art
The U.S. Department of Energy (DOE), Office of Energy Efficiency and Renewable Energy (EERE), has established the Energy Systems Integration Facility (ESIF) on the campus of the National Renewable Energy Laboratory (NREL) and has designated it as a DOE user facility. This 182,500-ft2 research facility provides state-of-the-art laboratory and support infrastructure to optimize the design and performance of electrical, thermal, fuel, and information technologies and systems at scale. This Facility Stewardship Plan provides DOE and other decision makers with information about the existing and expected capabilities of the ESIF and the expected performance metrics to be applied to ESIF operations.more » This plan is a living document that will be updated and refined throughout the lifetime of the facility.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wilson, A.
2001-05-16
Greening Federal Facilities, Second Edition, is a nuts-and-bolts resource guide compiled to increase energy and resource efficiency, cut waste, and improve the performance of Federal buildings and facilities. The guide highlights practical actions that facility managers, design and construction staff, procurement officials, and facility planners can take to save energy and money, improve the comfort and productivity of employees, and benefit the environment. It supports a national effort to promote energy and environmental efficiency in the nation's 500,000 Federal buildings and facilities. Topics covered include current Federal regulations; environmental and energy decision-making; site and landscape issues; building design; energy systems;more » water and wastewater; materials; waste management, and recycling; indoor environmental quality; and managing buildings.« less
National facilities study. Volume 4: Space operations facilities task group
NASA Technical Reports Server (NTRS)
1994-01-01
The principal objectives of the National Facilities Study (NFS) were to: (1) determine where U.S. facilities do not meet national aerospace needs; (2) define new facilities required to make U.S. capabilities 'world class' where such improvements are in the national interest; (3) define where consolidation and phase-out of existing facilities is appropriate; and (4) develop a long-term national plan for world-class facility acquisition and shared usage. The Space Operations Facilities Task Group defined discrete tasks to accomplish the above objectives within the scope of the study. An assessment of national space operations facilities was conducted to determine the nation's capability to meet the requirements of space operations during the next 30 years. The mission model used in the study to define facility requirements is described in Volume 3. Based on this model, the major focus of the Task Group was to identify any substantive overlap or underutilization of space operations facilities and to identify any facility shortfalls that would necessitate facility upgrades or new facilities. The focus of this initial study was directed toward facility recommendations related to consolidations, closures, enhancements, and upgrades considered necessary to efficiently and effectively support the baseline requirements model. Activities related to identifying facility needs or recommendations for enhancing U.S. international competitiveness and achieving world-class capability, where appropriate, were deferred to a subsequent study phase.
Energy, Society, and Education, with Emphasis on Educational Technology Policy for K-12
ERIC Educational Resources Information Center
Chedid, Loutfallah Georges
2005-01-01
This paper begins by examining the profound impact of energy usage on our lives, and on every major sector of the economy. Then, the anticipated US energy needs by the year 2025 are presented based on the Department of Energy's projections. The paper considers the much-touted National Energy Policy Report, and identifies a major flaw where the…
Analyzing industrial energy use through ordinary least squares regression models
NASA Astrophysics Data System (ADS)
Golden, Allyson Katherine
Extensive research has been performed using regression analysis and calibrated simulations to create baseline energy consumption models for residential buildings and commercial institutions. However, few attempts have been made to discuss the applicability of these methodologies to establish baseline energy consumption models for industrial manufacturing facilities. In the few studies of industrial facilities, the presented linear change-point and degree-day regression analyses illustrate ideal cases. It follows that there is a need in the established literature to discuss the methodologies and to determine their applicability for establishing baseline energy consumption models of industrial manufacturing facilities. The thesis determines the effectiveness of simple inverse linear statistical regression models when establishing baseline energy consumption models for industrial manufacturing facilities. Ordinary least squares change-point and degree-day regression methods are used to create baseline energy consumption models for nine different case studies of industrial manufacturing facilities located in the southeastern United States. The influence of ambient dry-bulb temperature and production on total facility energy consumption is observed. The energy consumption behavior of industrial manufacturing facilities is only sometimes sufficiently explained by temperature, production, or a combination of the two variables. This thesis also provides methods for generating baseline energy models that are straightforward and accessible to anyone in the industrial manufacturing community. The methods outlined in this thesis may be easily replicated by anyone that possesses basic spreadsheet software and general knowledge of the relationship between energy consumption and weather, production, or other influential variables. With the help of simple inverse linear regression models, industrial manufacturing facilities may better understand their energy consumption and production behavior, and identify opportunities for energy and cost savings. This thesis study also utilizes change-point and degree-day baseline energy models to disaggregate facility annual energy consumption into separate industrial end-user categories. The baseline energy model provides a suitable and economical alternative to sub-metering individual manufacturing equipment. One case study describes the conjoined use of baseline energy models and facility information gathered during a one-day onsite visit to perform an end-point energy analysis of an injection molding facility conducted by the Alabama Industrial Assessment Center. Applying baseline regression model results to the end-point energy analysis allowed the AIAC to better approximate the annual energy consumption of the facility's HVAC system.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1995-03-17
This report summarizes all work for the Energy Survey of Army Industrial Facilities, Energy Engineering Analysis Program (EEAP) at the Western Area Demilitarization Facility (WADF) of the Hawthorne Army Ammunition Plant (HWAAP), Hawthorne, Nevada, authorized under Contract No. DACA05-92-C-0155 with the U.S. Army Corps of Engineers, Sacramento District, California. The purpose of this energy survey is to develop a set of projects and actions that will reduce energy consumption and operating costs of selected facilities at the WADF. A preliminary inspection of facilities at WADF by Keller Gannon that identified potential retrofit opportunities was submitted as the EEAP Study andmore » Criteria Review in December 1993. This document formed the basis of the Detailed Scope of Work for this study. Facilities included in the survey and study, together with operational status.« less
Density of Indoor Tanning Facilities in 116 Large U.S. Cities
Hoerster, Katherine D.; Garrow, Rebecca L.; Mayer, Joni A.; Clapp, Elizabeth J.; Weeks, John R.; Woodruff, Susan I.; Sallis, James F.; Slymen, Donald J.; Patel, Minal R.; Sybert, Stephanie A.
2009-01-01
Background U.S. adolescents and young adults are using indoor tanning at high rates, even though it has been linked to both melanoma and squamous cell cancer. Because the availability of commercial indoor tanning facilities may influence use, data are needed on the number and density of such facilities. Methods In March 2006, commercial indoor tanning facilities in 116 large U.S. cities were identified, and the number and density (per 100,000 population) were computed for each city. Bivariate and multivariate analyses conducted in 2008 tested the association between tanning-facility density and selected geographic, climatologic, demographic, and legislative variables. Results Mean facility number and density across cities were 41.8 (SD=30.8) and 11.8 (SD=6.0), respectively. In multivariate analysis, cities with higher percentages of whites and lower ultraviolet (UV)index scores had significantly higher facility densities than those with lower percentages of whites and higher UV index scores. Conclusions These data indicate that commercial indoor tanning is widely available in the urban U.S., and this availability may help explain the high usage of indoor tanning. PMID:19215849
Density of indoor tanning facilities in 116 large U.S. cities.
Hoerster, Katherine D; Garrow, Rebecca L; Mayer, Joni A; Clapp, Elizabeth J; Weeks, John R; Woodruff, Susan I; Sallis, James F; Slymen, Donald J; Patel, Minal R; Sybert, Stephanie A
2009-03-01
U.S. adolescents and young adults are using indoor tanning at high rates, even though it has been linked to both melanoma and squamous cell cancer. Because the availability of commercial indoor tanning facilities may influence use, data are needed on the number and density of such facilities. In March 2006, commercial indoor tanning facilities in 116 large U.S. cities were identified, and the number and density (per 100,000 population) were computed for each city. Bivariate and multivariate analyses conducted in 2008 tested the association between tanning-facility density and selected geographic, climatologic, demographic, and legislative variables. Mean facility number and density across cities were 41.8 (SD=30.8) and 11.8 (SD=6.0), respectively. In multivariate analysis, cities with higher percentages of whites and lower ultraviolet (UV)index scores had significantly higher facility densities than those with lower percentages of whites and higher UV index scores. These data indicate that commercial indoor tanning is widely available in the urban U.S., and this availability may help explain the high usage of indoor tanning.
Maximizing freight movements in local food markets.
DOT National Transportation Integrated Search
2011-09-01
The past several years have seen a rising interest in all things sustainable, from energy efficient homes and vehicles, to alternative : energy sources, to increasing focus on recyclable and renewable material usage. This trend has also been accompan...
Improving urban district heating systems and assessing the efficiency of the energy usage therein
NASA Astrophysics Data System (ADS)
Orlov, M. E.; Sharapov, V. I.
2017-11-01
The report describes issues in connection with improving urban district heating systems from combined heat power plants (CHPs), to propose the ways for improving the reliability and the efficiency of the energy usage (often referred to as “energy efficiency”) in such systems. The main direction of such urban district heating systems improvement suggests transition to combined heating systems that include structural elements of both centralized and decentralized systems. Such systems provide the basic part of thermal power via highly efficient methods for extracting thermal power plants turbines steam, while peak loads are covered by decentralized peak thermal power sources to be mounted at consumers’ locations, with the peak sources being also reserve thermal power sources. The methodology was developed for assessing energy efficiency of the combined district heating systems, implemented as a computer software product capable of comparatively calculating saving on reference fuel for the system.
Ban on advertising promoting energy usage violates First Amendment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cohen, J.C.
In reversing the New York Court of Appeals in the Central Hudson Gas suit, the Supreme Court expanded the protection afforded commercial speech. The result could have a major impact on means used to achieve policy objectives of national and state energy conservation. Public utility commissions attempting to limit the growth of energy usage may have to devise stringent economic regulations that directly affect the marketplace and consumer alternatives. This might require an expansion of the statutory powers of public utility commissions. The Court's decision will require public utility commissions to either adopt regulations that restrict the content and formatmore » of utility speech or allocate costs to utility shareholders of impermissible advertising. Otherwise, a utility's unbridled ability to speak, given the economic power of such enterprises and their economic interest, could totally undermine the credibility of national and state energy-conservation policy. 12 references.« less
Energy Systems Integration Facility Overview
Arvizu, Dan; Chistensen, Dana; Hannegan, Bryan; Garret, Bobi; Kroposki, Ben; Symko-Davies, Martha; Post, David; Hammond, Steve; Kutscher, Chuck; Wipke, Keith
2018-01-16
The U.S. Department of Energy's Energy Systems Integration Facility (ESIF) is located at the National Renewable Energy Laboratory is the right tool, at the right time... a first-of-its-kind facility that addresses the challenges of large-scale integration of clean energy technologies into the energy systems that power the nation.
Jiang, Yuyuan; Bebee, Brian; Mendoza, Alvaro; Robinson, Alice K; Zhang, Xiaying; Rosso, Diego
2018-01-01
Mixing is the driver for the energy footprint of water resource recovery in lagoons. With the availability of solar-powered equipment, one potential measure to decrease the environmental impacts of treatment is to transition to an off-the-grid treatment. We studied the comparative scenarios of an existing grid-powered mixer and a solar-powered mixer. Testing was conducted to monitor the water quality, and to guarantee that the effluent concentrations were maintained equally between the two scenarios. Meanwhile, the energy consumption was recorded with the electrical energy monitor by the wastewater treatment utility, and the carbon emission changes were calculated using the emission intensity of the power utility. The results show that after the replacement, both energy usage and energy costs were significantly reduced, with the energy usage having decreased by 70% and its cost by 47%. Additionally, carbon-equivalent emission from electricity importation dropped by 64%, with an effect on the overall carbon emissions (i.e., including all other contributions from the process) decreasing from 3.8% to 1.5%. Copyright © 2017 Elsevier Ltd. All rights reserved.
How to "Kill a Watt" and Save Energy
ERIC Educational Resources Information Center
Massiha, G. H.; Houston, Shelton; Rawat, Kuldeep S.
2011-01-01
Many technology students--and especially those interested in environmental and energy issues--can benefit from learning about power ratings and the energy usage of electrical systems like the electrical equipment and appliances found in most homes. Students enrolled in electronics and construction technology courses learn to determine the power…
Cut Next Winter's Heating Bill Today.
ERIC Educational Resources Information Center
Sturgeon, Julie
1999-01-01
Presents specific steps that help make schools energy efficient and cut costs. Four basic strategies are suggested that include creating a database of energy usage that can also catch the occasional billing error, investigating less obvious ways of cutting energy use, such as applying cellulose commercial spray as an insulation choice, and…
Power Play: Calculating Home Electricity Consumption
ERIC Educational Resources Information Center
Roman, Harry T.
2007-01-01
With both energy usage and energy costs rising rapidly, people can benefit from paying closer attention to their consumption of energy. Students can gain greater awareness of their personal use of electricity and get some excellent experience with the practical application of mathematics by studying their families' consumption of electricity. A…
New NREL Research Facility Slashes Energy Use by 66 Percent
Thermal Test Facility, which serves as a showcase of energy-saving features and the home of NREL's cutting technologies now being developed at the Thermal Test Facility will help us reach this goal." The facility energy-efficient building design, NREL's Thermal Test Facility houses sophisticated equipment for
Bekker, Marthinus J; Cumming, Tania D; Osborne, Nikola K.P; Bruining, Angela M; McClean, Julia I; Leland, Louis S
2010-01-01
This experiment investigated the combined use of visual prompts, daily feedback, and rewards to reduce electricity consumption in a university residential hall. After a 17-day baseline period, the experimental intervention was introduced in the intervention hall, and no change was made in the control hall. Energy usage decreased in the intervention hall, but energy usage did not change appreciably in the control hall. In the intervention hall, mean daytime and nighttime savings were 16.2% and 10.7%, respectively, compared to savings of 3.8% (day) and 6.5% (night) in the control hall. PMID:21119909
NASA Astrophysics Data System (ADS)
Kilic, M.; Akyol, S. M.
2012-08-01
The air quality and thermal comfort strongly influenced by the heat and mass transfer take place together in an automobile cabin. In this study, it is aimed to investigate and assess the effects of air intake settings (recirculation and fresh air) on the thermal comfort, air quality satisfaction and energy usage during the cooling period of an automobile cabin. For this purpose, measurements (temperature, air velocity, CO2) were performed at various locations inside the cabin. Furthermore, whole body and local responses of the human subjects were noted while skin temperatures were measured. A mathematical model was arranged in order to estimate CO2 concentration and energy usage inside the vehicle cabin and verified with experimental data. It is shown that CO2 level inside of the cabin can be greater than the threshold value recommended for the driving safety if two and more occupants exist in the car. It is also shown that an advanced climate control system may satisfy the requirements for the air quality and thermal comfort as well as to reduce the energy usage for the cooling of a vehicle cabin.
Essays on consequences of economic integration
NASA Astrophysics Data System (ADS)
Chintrakarn, Pandej
2007-12-01
Economic integration is a term used to describe how different aspects between economies are integrated. As economic integration increases, the barriers of trade between markets diminishes. The most integrated economy today, between independent nations, is the European Union and its euro zone. This dissertation consists of three essays which examine consequences of economic integration. The debate over the environmental consequences of free trade is not only quite heated, but also entails significant policy ramifications. Recently, cross-sectional analysis at the country level has made use of exogenous determinants of trade to identify the causal effect of trade on the environment, finding moderate evidence of a beneficial impact of expanded trade on environmental quality. Given the stakes involved, the first essay revisits this finding using subnational data on 'trade' flows across US states and several measures of pollution. Not only does the analysis shed further light on the debate at the international level, but also addresses a heretofore unexamined question: Does greater inter-regional commerce at the subnational level harm the environment? The findings are striking, providing further evidence against a negative environmental impact of trade for the majority of measures analyzed. However, several sources of heterogeneity arise that are noteworthy. The second essay investigates the effect of the euro on trade among EMU members. Using various semi-nonparametric methods based on matching, the results suggest that the euro has a statistical and economic impact on trade. The results show that two countries sharing the euro currency trade somewhere between 9% and 14% more than other country-pairs. In addition, there is no evidence of trade diversion due to the euro. In one strand of research, analysts examine trends in and the determinants of energy usage and intensity. In a second strand, researchers analyze the impact of trade flows on environmental outcomes. Recently, Cole (2006) bridges this gap, analyzing the impact of trade intensity on energy usage utilizing panel data at the country level. Here, the third essay analyzes the impact of subnational trade flows across U.S. states on state-level energy usage and intensity, controlling for the endogeneity of trade flows. The findings indicate that an expansion of subnational trade at worst has no impact on state-level energy usage, and may actually reduce energy usage (contrary to Cole's country-level findings), although the impacts are not uniform across sectors.
Energy efficiency in California laboratory-type facilities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mills, E.; Bell, G.; Sartor, D.
The central aim of this project is to provide knowledge and tools for increasing the energy efficiency and performance of new and existing laboratory-type facilities in California. We approach the task along three avenues: (1) identification of current energy use and savings potential, (2) development of a {ital Design guide for energy- Efficient Research Laboratories}, and (3) development of a research agenda for focused technology development and improving out understanding of the market. Laboratory-type facilities use a considerable amount of energy resources. They are also important to the local and state economy, and energy costs are a factor in themore » overall competitiveness of industries utilizing laboratory-type facilities. Although the potential for energy savings is considerable, improving energy efficiency in laboratory-type facilities is no easy task, and there are many formidable barriers to improving energy efficiency in these specialized facilities. Insufficient motivation for individual stake holders to invest in improving energy efficiency using existing technologies as well as conducting related R&D is indicative of the ``public goods`` nature of the opportunity to achieve energy savings in this sector. Due to demanding environmental control requirements and specialized processes, laboratory-type facilities epitomize the important intersection between energy demands in the buildings sector and the industrial sector. Moreover, given the high importance and value of the activities conducted in laboratory-type facilities, they represent one of the most powerful contexts in which energy efficiency improvements stand to yield abundant non-energy benefits if properly applied.« less
[Utility of Smartphone in Home Care Medicine - First Trial].
Takeshige, Toshiyuki; Hirano, Chiho; Nakagawa, Midori; Yoshioka, Rentaro
2015-12-01
The use of video calls for home care can reduce anxiety and offer patients peace of mind. The most suitable terminals at facilities to support home care have been iPad Air and iPhone with FaceTime software. However, usage has been limited to specific terminals. In order to eliminate the need for special terminals and software, we have developed a program that has been customized to meet the needs of facilities using Web Real Time Communication(WebRTC)in cooperation with the University of Aizu. With this software, video calls can accommodate the large number of home care patients.
76 FR 62434 - Federal Property Suitable as Facilities To Assist the Homeless
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-07
... asbestos/PCBs Former SSA Bldg. 1230 12th Street Modesto CA 95354 Landholding Agency: GSA Property Number.... ft. through Sept. 30, 2012. Current usage: gov't offices, asbestos has been identified as well as.... Bldg., 3,713 sq. ft. for the garage, public space (roads and hwy) and utilities easements, asbestos and...
ERIC Educational Resources Information Center
Herring, William Rodney, Jr.
2009-01-01
A number of arguments appeared in the late-nineteenth-century United States about "correctness" in language, arguments for and against enforcing a standard of correctness and arguments about what should count as correct in language. Insofar as knowledge about and facility with "correct" linguistic usage could affect one's standing in the social…
The Challenge of Caring for Mildly Ill Children: A Canadian National Childcare Study
ERIC Educational Resources Information Center
Polyzoi, E.; Babb, J.C.
2004-01-01
This Canadian study of the care of mildly ill children in licensed childcare facilities compares director and parent preferences for eight models of care, exclusionary practices for ill children by directors, and preferred backup care options of parents. It also investigates anticipated usage and willingness of parents to pay for emergency…
DCDM1: Lessons Learned from the World's Most Energy Efficient Data Center
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sickinger, David E; Van Geet, Otto D; Carter, Thomas
This presentation discusses the holistic approach to design the world's most energy-efficient data center, which is located at the U.S. Department of Energy National Renewable Energy Laboratory (NREL). This high-performance computing (HPC) data center has achieved a trailing twelve-month average power usage effectiveness (PUE) of 1.04 and features a chiller-less design, component-level warm-water liquid cooling, and waste heat capture and reuse. We provide details of the demonstrated PUE and energy reuse effectiveness (ERE) and lessons learned during four years of production operation. Recent efforts to dramatically reduce the water footprint will also be discussed. Johnson Controls partnered with NREL andmore » Sandia National Laboratories to deploy a thermosyphon cooler (TSC) as a test bed at NREL's HPC data center that resulted in a 50% reduction in water usage during the first year of operation. The Thermosyphon Cooler Hybrid System (TCHS) integrates the control of a dry heat rejection device with an open cooling tower.« less
Eco Assist Techniques through Real-time Monitoring of BEV Energy Usage Efficiency
Kim, Younsun; Lee, Ingeol; Kang, Sungho
2015-01-01
Energy efficiency enhancement has become an increasingly important issue for battery electric vehicles. Even if it can be improved in many ways, the driver’s driving pattern strongly influences the battery energy consumption of a vehicle. In this paper, eco assist techniques to simply implement an energy-efficient driving assistant system are introduced, including eco guide, eco control and eco monitoring methods. The eco guide is provided to control the vehicle speed and accelerator pedal stroke, and eco control is suggested to limit the output power of the battery. For eco monitoring, the eco indicator and eco report are suggested to teach eco-friendly driving habits. The vehicle test, which is done in four ways, consists of federal test procedure (FTP)-75, new european driving cycle (NEDC), city and highway cycles, and visual feedback with audible warnings is provided to attract the driver’s voluntary participation. The vehicle test result shows that the energy usage efficiency can be increased up to 19.41%. PMID:26121611
Optimal trajectory planning for a UAV glider using atmospheric thermals
NASA Astrophysics Data System (ADS)
Kagabo, Wilson B.
An Unmanned Aerial Vehicle Glider (UAV glider) uses atmospheric energy in its different forms to remain aloft for extended flight durations. This UAV glider's aim is to extract atmospheric thermal energy and use it to supplement its battery energy usage and increase the mission period. Given an infrared camera identified atmospheric thermal of known strength and location; current wind speed and direction; current battery level; altitude and location of the UAV glider; and estimating the expected altitude gain from the thermal, is it possible to make an energy-efficient based motivation to fly to an atmospheric thermal so as to achieve UAV glider extended flight time? For this work, an infrared thermal camera aboard the UAV glider takes continuous forward-looking ground images of "hot spots". Through image processing a candidate atmospheric thermal strength and location is estimated. An Intelligent Decision Model incorporates this information with the current UAV glider status and weather conditions to provide an energy-based recommendation to modify the flight path of the UAV glider. Research, development, and simulation of the Intelligent Decision Model is the primary focus of this work. Three models are developed: (1) Battery Usage Model, (2) Intelligent Decision Model, and (3) Altitude Gain Model. The Battery Usage Model comes from the candidate flight trajectory, wind speed & direction and aircraft dynamic model. Intelligent Decision Model uses a fuzzy logic based approach. The Altitude Gain Model requires the strength and size of the thermal and is found a priori.
Energy use of televisions and video cassette recorders in the U.S.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meier, Alan; Rosen, Karen
1999-03-01
In an effort to more accurately determine nationwide energy consumption, the U.S. Department of Energy has recently commissioned studies with the goal of improving its understanding of the energy use of appliances in the miscellaneous end-use category. This study presents an estimate of the residential energy consumption of two of the most common domestic appliances in the miscellaneous end-use category: color televisions (TVs) and video cassette recorders (VCRs). The authors used a bottom-up approach in estimating national TV and VCR energy consumption. First, they obtained estimates of stock and usage from national surveys, while TV and VCR power measurements andmore » other data were recorded at repair and retail shops. Industry-supplied shipment and sales distributions were then used to minimize bias in the power measurement samples. To estimate national TV and VCR energy consumption values, ranges of power draw and mode usage were created to represent situations in homes with more than one unit. Average energy use values for homes with one unit, two units, etc. were calculated and summed to provide estimates of total national TV and VCR energy consumption.« less
Wireless Sensor for Measuring Pump Efficiency: Small Business Voucher Project with KCF Technologies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fugate, David L.; Liu, Xiaobing; Gehl, Anthony C.
This document is to fulfill the final report requirements for the Small Business Voucher (SBV) CRADA project with ORNL and KCF Technologies (CRADA/NFE-16-06133). Pumping systems account for nearly 20% of the world’s electrical energy demand and range from 25-50% of the energy usage in many industrial and building power plants. The energy cost is the largest element in the total cost of owning a pump (~40%). In response to a recent DOE mandate for improved pump efficiency pump manufacturers are preparing for the changes that the impending regulations will bring, including design improvements. This mandate also establishes a need formore » new low cost pump efficiency measurement systems. The standard industry definition of pump efficiency is the mechanical water horsepower delivered divided by the electrical horsepower input to the motor. KCF Technologies has developed a new sensor measurement technique to estimate fluid pump efficiency using a thermodynamic approach. KCF Technologies applied for a SBV grant with ORNL as the research partner. KCF needed a research partner with the proper facilities to demonstrate the efficacy of its wireless sensor unit for measuring pump efficiency. The ORNL Building Technologies Research and Integration Center (BTRIC) test resources were used to test and demonstrate the successful measurement of pump efficiency with the KCF sensor technology. KCF is now working on next steps to commercialize this sensing technology.« less
Application of the Software as a Service Model to the Control of Complex Building Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stadler, Michael; Donadee, Jonathan; Marnay, Chris
2011-03-17
In an effort to create broad access to its optimization software, Lawrence Berkeley National Laboratory (LBNL), in collaboration with the University of California at Davis (UC Davis) and OSISoft, has recently developed a Software as a Service (SaaS) Model for reducing energy costs, cutting peak power demand, and reducing carbon emissions for multipurpose buildings. UC Davis currently collects and stores energy usage data from buildings on its campus. Researchers at LBNL sought to demonstrate that a SaaS application architecture could be built on top of this data system to optimize the scheduling of electricity and heat delivery in the building.more » The SaaS interface, known as WebOpt, consists of two major parts: a) the investment& planning and b) the operations module, which builds on the investment& planning module. The operational scheduling and load shifting optimization models within the operations module use data from load prediction and electrical grid emissions models to create an optimal operating schedule for the next week, reducing peak electricity consumption while maintaining quality of energy services. LBNL's application also provides facility managers with suggested energy infrastructure investments for achieving their energy cost and emission goals based on historical data collected with OSISoft's system. This paper describes these models as well as the SaaS architecture employed by LBNL researchers to provide asset scheduling services to UC Davis. The peak demand, emissions, and cost implications of the asset operation schedule and investments suggested by this optimization model are analysed.« less
Application of the Software as a Service Model to the Control of Complex Building Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stadler, Michael; Donadee, Jon; Marnay, Chris
2011-03-18
In an effort to create broad access to its optimization software, Lawrence Berkeley National Laboratory (LBNL), in collaboration with the University of California at Davis (UC Davis) and OSISoft, has recently developed a Software as a Service (SaaS) Model for reducing energy costs, cutting peak power demand, and reducing carbon emissions for multipurpose buildings. UC Davis currently collects and stores energy usage data from buildings on its campus. Researchers at LBNL sought to demonstrate that a SaaS application architecture could be built on top of this data system to optimize the scheduling of electricity and heat delivery in the building.more » The SaaS interface, known as WebOpt, consists of two major parts: a) the investment& planning and b) the operations module, which builds on the investment& planning module. The operational scheduling and load shifting optimization models within the operations module use data from load prediction and electrical grid emissions models to create an optimal operating schedule for the next week, reducing peak electricity consumption while maintaining quality of energy services. LBNL's application also provides facility managers with suggested energy infrastructure investments for achieving their energy cost and emission goals based on historical data collected with OSISoft's system. This paper describes these models as well as the SaaS architecture employed by LBNL researchers to provide asset scheduling services to UC Davis. The peak demand, emissions, and cost implications of the asset operation schedule and investments suggested by this optimization model are analyzed.« less
Technological and life cycle assessment of organics processing odour control technologies.
Bindra, Navin; Dubey, Brajesh; Dutta, Animesh
2015-09-15
As more municipalities and communities across developed world look towards implementing organic waste management programmes or upgrading existing ones, composting facilities are emerging as a popular choice. However, odour from these facilities continues to be one of the most important concerns in terms of cost & effective mitigation. This paper provides a technological and life cycle assessment of some of the different odour control technologies and treatment methods that can be implemented in organics processing facilities. The technological assessment compared biofilters, packed tower wet scrubbers, fine mist wet scrubbers, activated carbon adsorption, thermal oxidization, oxidization chemicals and masking agents. The technologies/treatment methods were evaluated and compared based on a variety of operational, usage and cost parameters. Based on the technological assessment it was found that, biofilters and packed bed wet scrubbers are the most applicable odour control technologies for use in organics processing faculties. A life cycle assessment was then done to compare the environmental impacts of the packed-bed wet scrubber system, organic (wood-chip media) bio-filter and inorganic (synthetic media) bio-filter systems. Twelve impact categories were assessed; cumulative energy demand (CED), climate change, human toxicity, photochemical oxidant formation, metal depletion, fossil depletion, terrestrial acidification, freshwater eutrophication, marine eutrophication, terrestrial eco-toxicity, freshwater eco-toxicity and marine eco-toxicity. The results showed that for all impact categories the synthetic media biofilter had the highest environmental impact, followed by the wood chip media bio-filter system. The packed-bed system had the lowest environmental impact for all categories. Copyright © 2015 Elsevier B.V. All rights reserved.
Code of Federal Regulations, 2010 CFR
2010-07-01
... policy must Federal agencies follow in the management of facilities? 102-74.155 Section 102-74.155 Public... MANAGEMENT REGULATION REAL PROPERTY 74-FACILITY MANAGEMENT Facility Management Energy Conservation § 102-74.155 What energy conservation policy must Federal agencies follow in the management of facilities...
Cummins, Enda J; McDonnell, Kevin P; Ward, Shane M
2006-05-01
Due to the ban on meat and bone meal (MBM) as an animal feed, combustion with energy recovery has been considered a viable alternative usage for the mounting stocks of MBM. The effects of the co-combustion of MBM and peat on flue gas emissions and fluidisation were studied using a bubbling fluidised bed (BFB) test facility (20 kW). The dispersion of emissions such as nitrogen dioxide (NO2), sulphur dioxide (SO2), carbon monoxide (CO), hydrogen chloride (HCl) and particulates was investigated for a proposed site and compared to the relevant national and international regulations. Concentrations of NO2, CO and HCl were less than 10% of legislative and guideline thresholds while ground level concentrations of SO2 were also below relevant EU and world guidelines. The results indicate the potential for using MBM as a co-fuel with peat in a BFB while maintaining high air quality standards.
Recent Advances on Bioethanol Dehydration using Zeolite Membrane
NASA Astrophysics Data System (ADS)
Makertihartha, I. G. B. N.; Dharmawijaya, P. T.; Wenten, I. G.
2017-07-01
Renewable energy has gained increasing attention throughout the world. Bioethanol has the potential to replace existing fossil fuel usage without much modification in existing facilities. Bioethanol which generally produced from fermentation route produces low ethanol concentration. However, fuel grade ethanol requires low water content to avoid engine stall. Dehydration process has been increasingly important in fuel grade ethanol production. Among all dehydration processes, pervaporation is considered as the most promising technology. Zeolite possesses high potential in pervaporation of bioethanol into fuel grade ethanol. Zeolite membrane can either remove organic (ethanol) from aqueous mixture or water from the mixture, depending on the framework used. Hydrophilic zeolite membrane, e.g. LTA, can easily remove water from the mixture leaving high ethanol concentration. On the other hand, hydrophobic zeolite membrane, e.g. silicate-1, can remove ethanol from aqueous solution. This review presents the concept of bioethanol dehydration using zeolite membrane. Special attention is given to the performance of selected pathway related to framework selection.
Energy efficiency trade-offs drive nucleotide usage in transcribed regions
Chen, Wei-Hua; Lu, Guanting; Bork, Peer; Hu, Songnian; Lercher, Martin J.
2016-01-01
Efficient nutrient usage is a trait under universal selection. A substantial part of cellular resources is spent on making nucleotides. We thus expect preferential use of cheaper nucleotides especially in transcribed sequences, which are often amplified thousand-fold compared with genomic sequences. To test this hypothesis, we derive a mutation-selection-drift equilibrium model for nucleotide skews (strand-specific usage of ‘A' versus ‘T' and ‘G' versus ‘C'), which explains nucleotide skews across 1,550 prokaryotic genomes as a consequence of selection on efficient resource usage. Transcription-related selection generally favours the cheaper nucleotides ‘U' and ‘C' at synonymous sites. However, the information encoded in mRNA is further amplified through translation. Due to unexpected trade-offs in the codon table, cheaper nucleotides encode on average energetically more expensive amino acids. These trade-offs apply to both strand-specific nucleotide usage and GC content, causing a universal bias towards the more expensive nucleotides ‘A' and ‘G' at non-synonymous coding sites. PMID:27098217
Bed usage in a Dublin teaching hospital: a prospective audit.
John, A; Breen, D P; Ghafar, Aabdul; Olphert, T; Burke, C M
2004-01-01
We prospectively audited inpatient bed use in our hospital for the first three months of this year. While 70% (mean age 54 +/- 20.8 years) of our patients went home on the day they were medically discharged, 30% (mean age 70.3 +/- 18.3 years) remained in the hospital awaiting step-down facilities. The total of 486 bed days occupied by overstaying patients would if available, have allowed treatment of 54% more patients without any increase in the hospital complement of beds, preventing the cancellation of elective procedures and preventing patients remaining on trolleys overnight. These prospective data emphasise (1) a highly inefficient use of acute hospital beds; (2) the need for step-down facilities; (3) efficient use of existing hospital beds is the highest priority both for optimal patient care and optimal use of expensive hospital resources; (4) efficient use of existing facilities should be achieved before the construction of additional facilities.
Options to improve energy efficiency for educational building
NASA Astrophysics Data System (ADS)
Jahan, Mafruha
The cost of energy is a major factor that must be considered for educational facility budget planning purpose. The analysis of energy related issues and options can be complex and requires significant time and detailed effort. One way to facilitate the inclusion of energy option planning in facility planning efforts is to utilize a tool that allows for quick appraisal of the facility energy profile. Once such an appraisal is accomplished, it is then possible to rank energy improvement options consistently with other facility needs and requirements. After an energy efficiency option has been determined to have meaningful value in comparison with other facility planning options, it is then possible to utilize the initial appraisal as the basis for an expanded consideration of additional facility and energy use detail using the same analytic system used for the initial appraisal. This thesis has developed a methodology and an associated analytic model to assist in these tasks and thereby improve the energy efficiency of educational facilities. A detailed energy efficiency and analysis tool is described that utilizes specific university building characteristics such as size, architecture, envelop, lighting, occupancy, thermal design which allows reducing the annual energy consumption. Improving the energy efficiency of various aspects of an educational building's energy performance can be complex and can require significant time and experience to make decisions. The approach developed in this thesis initially assesses the energy design for a university building. This initial appraisal is intended to assist administrators in assessing the potential value of energy efficiency options for their particular facility. Subsequently this scoping design can then be extended as another stage of the model by local facility or planning personnel to add more details and engineering aspects to the initial screening model. This approach can assist university planning efforts to identify the most cost effective combinations of energy efficiency strategies. The model analyzes and compares the payback periods of all proposed Energy Performance Measures (EPMs) to determine which has the greatest potential value.
Al-Subaiee, Faisal Sultan
2015-01-01
This study aimed to identify some socioeconomic factors affecting local people in central Riyadh area for the utilization of wood and other energy sources in cooking and heating in order to develop some recommendations for conserving woodlands. The study results revealed that gas is the most common energy source used for cooking with a mean usage level of 2.79 (SD = 0.58). On the other hand, wood ranked first for heating with the highest mean, usage level of 1.90 (SD = 1.06). However, electricity and gas as sources of energy for heating ranked second and third with mean usage level of 1.81 and 0.80 respectively. The study revealed that local people with the university education were significantly making higher use of electricity for both cooking and heating and those with no formal education ranked the highest on wood use for both cooking and heating. In addition, those living in traditional houses significantly used more wood for cooking than those living in villas and apartments. Also, local people with high income levels significantly were using more electricity for heating than others. The study recommended conducting extension and environmental awareness raising programs to enhance local residents’ adoption of wood substitutes, promoting employment opportunities for unemployed locals, and subsidizing prices of alternative energy sources. PMID:27081355
Correlates of service utilization among homeless youth.
Tyler, Kimberly A; Akinyemi, Sarah L; Kort-Butler, Lisa A
2012-07-01
Though few studies exist on service utilization among homeless youth in the U.S., services are important because without them, many of these young people may resort to delinquent strategies in order to meet their daily survival needs. The current study examines frequency and correlates of service utilization (i.e., shelters, food programs, street outreach, counseling, STI and HIV testing) among a sample of 249 homeless youth ages 14 to 21. Multivariate analysis revealed significant differences in service usage by sex, age, and sexual orientation. Experiencing family physical and/or sexual abuse, being kicked out of the family home, spending more nights per week sleeping on the street, and having ever stayed in a group home facility were significant correlates of homeless youths' service usage.
Monitoring agricultural processing electrical energy use and efficiency
USDA-ARS?s Scientific Manuscript database
Energy costs have become proportionately larger as cotton post-harvest processing facilities have utilized other inputs more efficiently. A discrepancy in energy consumption per unit processed between facilities suggests that energy could be utilized more efficiently. Cotton gin facilities were in...
Mohammadpour, Atefeh; Anumba, Chimay J; Messner, John I
2016-07-01
There is a growing focus on enhancing energy efficiency in healthcare facilities, many of which are decades old. Since replacement of all aging healthcare facilities is not economically feasible, the retrofitting of these facilities is an appropriate path, which also provides an opportunity to incorporate energy efficiency measures. In undertaking energy efficiency retrofits, it is vital that the safety of the patients in these facilities is maintained or enhanced. However, the interactions between patient safety and energy efficiency have not been adequately addressed to realize the full benefits of retrofitting healthcare facilities. To address this, an innovative integrated framework, the Patient Safety and Energy Efficiency (PATSiE) framework, was developed to simultaneously enhance patient safety and energy efficiency. The framework includes a step -: by -: step procedure for enhancing both patient safety and energy efficiency. It provides a structured overview of the different stages involved in retrofitting healthcare facilities and improves understanding of the intricacies associated with integrating patient safety improvements with energy efficiency enhancements. Evaluation of the PATSiE framework was conducted through focus groups with the key stakeholders in two case study healthcare facilities. The feedback from these stakeholders was generally positive, as they considered the framework useful and applicable to retrofit projects in the healthcare industry. © The Author(s) 2016.
10 CFR 1016.12 - Termination of security facility approval.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 4 2011-01-01 2011-01-01 false Termination of security facility approval. 1016.12 Section 1016.12 Energy DEPARTMENT OF ENERGY (GENERAL PROVISIONS) SAFEGUARDING OF RESTRICTED DATA Physical Security § 1016.12 Termination of security facility approval. Security facility approval will be terminated...
10 CFR 1016.12 - Termination of security facility approval.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 4 2010-01-01 2010-01-01 false Termination of security facility approval. 1016.12 Section 1016.12 Energy DEPARTMENT OF ENERGY (GENERAL PROVISIONS) SAFEGUARDING OF RESTRICTED DATA Physical Security § 1016.12 Termination of security facility approval. Security facility approval will be terminated...
Grid Facilities | Grid Modernization | NREL
groundbreaking innovations and collaboration in grid research. Photo of the Energy Systems Integration Facility Energy Systems Integration Facility The Energy Systems Integration Facility is the nation's premier user Located in Boulder, Colorado, the National Wind Technology Center (NWTC) offers similar integration
Sustainable Energy for University Science Majors: Developing Guidelines for Educators
ERIC Educational Resources Information Center
Langbeheim, Elon; Rez, Peter
2017-01-01
This paper describes the basic tenets of a sustainable energy course for university science majors. First, it outlines the three core components of the course: (1) The scientific evidence for the connection between climate change and energy usage; (2) An analysis of the capacity and environmental impact of various renewable and traditional energy…
Renewable Energy Feasibility Study Final Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rooney, Tim
2013-10-30
The Gila River Indian Community (GRIC or the Community) contracted the ANTARES Group, Inc. (“ANTARES”) to assess the feasibility of solar photovoltaic (PV) installations. A solar energy project could provide a number of benefits to the Community in terms of potential future energy savings, increased employment, environmental benefits from renewable energy generation and usage, and increased energy self-sufficiency. The study addresses a number of facets of a solar project’s overall feasibility, including: Technical appropriateness; Solar resource characteristics and expected system performance; Levelized cost of electricity (LCOE) economic assessment. The Gila River Indian Community (GRIC or the Community) contracted the ANTARESmore » Group, Inc. (“ANTARES”) to prepare a biomass resource assessment study and evaluate the feasibility of a bioenergy project on Community land. A biomass project could provide a number of benefits to the Community in terms of increased employment, environmental benefits from renewable energy generation and usage, and increased energy self-sufficiency. The study addresses a number of facets of a biomass project’s overall feasibility, including: Resource analysis and costs; Identification of potential bioenergy projects; Technical and economic (levelized cost of energy) modeling for selected project configuration.« less
Effectiveness of a night radiative cooling system in different geographical latitudes
NASA Astrophysics Data System (ADS)
Tsoy, A. P.; Granovskiy, A. S.; Baranenko, A. V.; Tsoy, D. A.
2017-08-01
Growth of world energy consumption and depletion of energy resources make humanity to constantly work on the creation of the energy efficient technologies and increase usage of the alternative and renewable sources of energy. One of such alternative sources of energy is the night radiative cooling (NRC). NRC is an alternative and renewable source of energy, derived from the effective radiation of the Earth into the Space. If the given surface is located so that it looks to the night sky, then under the particular condition more energy can be generated under the effect of radiative cooling, than received from the atmosphere. As a result the temperature of the surface can be kept lower than the temperature of the ambient air. This effect can be used for creation of the refrigeration systems with the low energy consumption and as a result lower negative influence on the environment. During the research it has been identified that the possibility of the NRC usage is mostly predetermined by the specifics of the climate of the each region. In particular climate conditions the refrigeration systems working on night radiative cooling will be more effective that in others.
Energy Equity Lost and Found: Rebuilding America's K-12 Schools.
ERIC Educational Resources Information Center
Schoff, Lorenz V.
1999-01-01
Discusses reversing the trend of school-building deterioration and inefficient energy usage through the Rebuild America program. Explains what Rebuild America is and why schools should join the program. Also provided are overviews of successful programs involving schools. (GR)
Achieving scale strategically : understanding freight flows in regional food supply chains.
DOT National Transportation Integrated Search
2013-06-01
The past several years have seen a rising interest in all things sustainable, from energy efficient homes : and vehicles, to alternative energy sources, to increasing focus on recyclable and renewable material : usage. This trend has also been accomp...
Analyzing How We Do Analysis and Consume Data, Results from the SciDAC-Data Project
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ding, P.; Aliaga, L.; Mubarak, M.
One of the main goals of the Dept. of Energy funded SciDAC-Data project is to analyze the more than 410,000 high energy physics datasets that have been collected, generated and defined over the past two decades by experiments using the Fermilab storage facilities. These datasets have been used as the input to over 5.6 million recorded analysis projects, for which detailed analytics have been gathered. The analytics and meta information for these datasets and analysis projects are being combined with knowledge of their part of the HEP analysis chains for major experiments to understand how modern computing and data deliverymore » is being used. We present the first results of this project, which examine in detail how the CDF, D0, NOvA, MINERvA and MicroBooNE experiments have organized, classified and consumed petascale datasets to produce their physics results. The results include analysis of the correlations in dataset/file overlap, data usage patterns, data popularity, dataset dependency and temporary dataset consumption. The results provide critical insight into how workflows and data delivery schemes can be combined with different caching strategies to more efficiently perform the work required to mine these large HEP data volumes and to understand the physics analysis requirements for the next generation of HEP computing facilities. In particular we present a detailed analysis of the NOvA data organization and consumption model corresponding to their first and second oscillation results (2014-2016) and the first look at the analysis of the Tevatron Run II experiments. We present statistical distributions for the characterization of these data and data driven models describing their consumption« less
Analyzing how we do Analysis and Consume Data, Results from the SciDAC-Data Project
NASA Astrophysics Data System (ADS)
Ding, P.; Aliaga, L.; Mubarak, M.; Tsaris, A.; Norman, A.; Lyon, A.; Ross, R.
2017-10-01
One of the main goals of the Dept. of Energy funded SciDAC-Data project is to analyze the more than 410,000 high energy physics datasets that have been collected, generated and defined over the past two decades by experiments using the Fermilab storage facilities. These datasets have been used as the input to over 5.6 million recorded analysis projects, for which detailed analytics have been gathered. The analytics and meta information for these datasets and analysis projects are being combined with knowledge of their part of the HEP analysis chains for major experiments to understand how modern computing and data delivery is being used. We present the first results of this project, which examine in detail how the CDF, D0, NOvA, MINERvA and MicroBooNE experiments have organized, classified and consumed petascale datasets to produce their physics results. The results include analysis of the correlations in dataset/file overlap, data usage patterns, data popularity, dataset dependency and temporary dataset consumption. The results provide critical insight into how workflows and data delivery schemes can be combined with different caching strategies to more efficiently perform the work required to mine these large HEP data volumes and to understand the physics analysis requirements for the next generation of HEP computing facilities. In particular we present a detailed analysis of the NOvA data organization and consumption model corresponding to their first and second oscillation results (2014-2016) and the first look at the analysis of the Tevatron Run II experiments. We present statistical distributions for the characterization of these data and data driven models describing their consumption.
10 CFR 611.206 - Existing facilities.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 4 2013-01-01 2013-01-01 false Existing facilities. 611.206 Section 611.206 Energy DEPARTMENT OF ENERGY (CONTINUED) ASSISTANCE REGULATIONS ADVANCED TECHNOLOGY VEHICLES MANUFACTURER ASSISTANCE PROGRAM Facility/Funding Awards § 611.206 Existing facilities. The Secretary shall, in making awards to those manufacturers that have existing...
10 CFR 611.206 - Existing facilities.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 4 2011-01-01 2011-01-01 false Existing facilities. 611.206 Section 611.206 Energy DEPARTMENT OF ENERGY (CONTINUED) ASSISTANCE REGULATIONS ADVANCED TECHNOLOGY VEHICLES MANUFACTURER ASSISTANCE PROGRAM Facility/Funding Awards § 611.206 Existing facilities. The Secretary shall, in making awards to those manufacturers that have existing...
10 CFR 611.206 - Existing facilities.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 4 2014-01-01 2014-01-01 false Existing facilities. 611.206 Section 611.206 Energy DEPARTMENT OF ENERGY (CONTINUED) ASSISTANCE REGULATIONS ADVANCED TECHNOLOGY VEHICLES MANUFACTURER ASSISTANCE PROGRAM Facility/Funding Awards § 611.206 Existing facilities. The Secretary shall, in making awards to those manufacturers that have existing...
10 CFR 611.206 - Existing facilities.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 4 2012-01-01 2012-01-01 false Existing facilities. 611.206 Section 611.206 Energy DEPARTMENT OF ENERGY (CONTINUED) ASSISTANCE REGULATIONS ADVANCED TECHNOLOGY VEHICLES MANUFACTURER ASSISTANCE PROGRAM Facility/Funding Awards § 611.206 Existing facilities. The Secretary shall, in making awards to those manufacturers that have existing...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-10
...] Information Collection: Renewable Energy and Alternate Uses of Existing Facilities on the Outer Continental... requirements in the regulations under ``Renewable Energy and Alternate Uses of Existing Facilities on the Outer..., transportation, or transmission of energy from sources other than oil and gas (renewable energy). Specifically...
Capsule review of the DOE research and development and field facilities
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
1980-09-01
A description is given of the roles of DOE's headquarters, field offices, major multiprogram laboratories, Energy Technology and Mining Technology Centers, and other government-owned, contractor-operated facilities, which are located in all regions of the US. Descriptions of DOE facilities are given for multiprogram laboratories (12); program-dedicated facilities (biomedical and environmental facilities-12, fossil energy facilities-7, fusion energy facility-1, nuclear development facilities-3, physical research facilities-4, safeguards facility-1, and solar facilities-2); and Production, Testing, and Fabrication Facilities (nuclear materials production facilities-5, weapon testing and fabrication complex-8). Three appendices list DOE field and project offices; DOE field facilities by state or territory, names, addresses,more » and telephone numbers; DOE R and D field facilities by type, contractor names, and names of directors. (MCW)« less
Usir, Ezlina; Lua, Pei Lin; Majeed, Abu Bakar Abdul
2012-06-01
This study aimed to determine the availability and usage of printed and electronic references and Patient Medication Record in community pharmacy. It was conducted for over 3 months from 15 January to 30 April 2007. Ninety-three pharmacies participated. Structured questionnaires were mailed to community pharmacies. Six weeks later a reminder was sent to all non responders, who were given another six weeks to return the completed questionnaire. Outcomes were analyzed using descriptive statistics and chi-square test of independence. Almost all the pharmacies (96.8%) have at least Monthly Index of Medical Specialties (MIMS) while 78.5% have at least MIMS ANNUAL in their stores. Only about a third (31.2%) of the pharmacies were equipped with online facilities of which the majority referred to medical websites (88.9%) with only a minority (11.1%) referring to electronic journals. More than half (59.1%) of the pharmacists kept Patient Medication Record profiles with 49.1% storing it in paper, 41.8% electronically and 9.1% in both printed and electronic versions. In general, prevalence and usage of electronic references in community pharmacies were rather low. Efforts should be increased to encourage wider usage of electronic references and Patient Medication Records in community pharmacies to facilitate pharmaceutical care.
Gopalan, Saji S; Das, Ashis; Howard, Natasha
2017-03-15
Fragile and conflict-affected situations (FCS) in Asia and the Middle-East contribute significantly to global maternal and neonatal deaths. This systematic review explored maternal and neonatal health (MNH) services usage and determinants in FCS in Asia and the Middle-East to inform policy on health service provision in these challenging settings. This systematic review was conducted using a standardised protocol. Pubmed, Embase, Web of Science, and selected development agency websites were searched for studies meeting inclusion criteria. Studies were assessed for methodological quality using an adapted evaluation tool. Qualitative and quantitative data were synthesized and pooled odds ratios generated for meta-analysis of service-usage determinants. Of 18 eligible peer-reviewed studies, eight were from Nepal, four from Afghanistan, and two each from Iraq, Yemen, and the Palestinian Territories. Fragile situations provide limited evidence on emergency obstetric care, postnatal care, and newborn services. Usage of MNH services was low in all FCS, irrespective of economic growth level. Demand-side determinants of service-usage were transportation, female education, autonomy, health awareness, and ability-to-pay. Supply-side determinants included service availability and quality, existence of community health-workers, costs, and informal payments in health facilities. Evidence is particularly sparse on MNH in acute crises, and remains limited in fragile situations generally. Findings emphasize that poor MNH status in FCS is a leading contributor to the burden of maternal and neonatal ill-health in Asia and the Middle-East. Essential services for skilled birth attendance and emergency obstetric, newborn, and postnatal care require improvement in FCS. FCS require additional resources and policy attention to address the barriers to appropriate MNH care. Authors discuss the 'targeted policy approach for vulnerable groups' as a means of addressing MNH service usage inequities.
Feasibility Investigation for a Solar Power Generation Facility
NASA Technical Reports Server (NTRS)
Nathan, Lakshmi
2010-01-01
The Energy Policy Act of 2005 states that by fiscal year 2013, at least 7.5% of the energy consumed by the government must be renewable energy. In an effort to help meet this goal, Johnson Space Center (JSC) is considering installing a solar power generation facility. The purpose of this project is to conduct a feasibility investigation for such a facility. Because Kennedy Space Center (KSC) has a solar power generation facility, the first step in this investigation is to learn about KSC's facility and obtain information on how it was constructed. After collecting this information, the following must be determined: the amount of power desired, the size of the facility, potential locations for it, and estimated construction and maintenance costs. Contacts with JSC's energy provider must also be established to determine if a partnership would be agreeable to both parties. Lastly, all of this data must be analyzed to decide whether or not JSC should construct the facility. The results from analyzing the data collected indicate that a 200 kW facility would provide enough energy to meet 1% of JSC's energy demand. This facility would require less than 1 acre of land. In the map below, potential locations are shown in green. The solar power facility is projected to cost $2 M. So far, the information collected indicates that such a facility could be constructed. The next steps in this investigation include contacting JSC's energy provider, CenterPoint Energy, to discuss entering a partnership; developing a life cycle cost analysis to determine payback time; developing more detailed plans; and securing funding.
NASA Astrophysics Data System (ADS)
Rodriguez-Winter, Thelma
All man-made structures and materials have a design life. Across the United States there is a common theme for our water and wastewater treatment facilities and infrastructure. The design life of many of our mid 20 th century water and wastewater infrastructures in the United States have reached or are reaching life expectancy limits (ASCE, 2010). To compound the financial crisis of keeping up with the degradation, meeting and exceeding quality standards has never been more important in order to protect local fresh water supplies. This thesis analyzes the energy consumption of a municipal water and wastewater treatment system from a Lake Erie intake through potable treatment and back through wastewater treatment then discharge. The system boundary for this thesis includes onsite energy consumed by the treatment system and distribution/reclamation system as well as the energy consumed by the manufacturing of treatment chemicals applied during the study periods. By analyzing energy consumption, subsequent implications from greenhouse gas emissions and financial expenditures were quantified. Through the segregation of treatment and distribution processes from non-process energy consumption, such as heating, lighting, and air handling, this study identified that the potable water treatment system consumed an annual average of 2.42E+08 kBtu, spent 5,812,144 for treatment and distribution, and emitted 28,793 metric tons of CO2 equivalent emissions. Likewise, the wastewater treatment system consumed an annual average of 2.45E+08 kBtu, spent 3,331,961 for reclamation and treatment, and emitted 43,780 metric tons of CO2 equivalent emissions. The area with the highest energy usage, financial expenditure, and greenhouse gas emissions for the potable treatment facility and distribution system was from the manufacturing of the treatment chemicals, 1.10E+08 kBtu, 3.7 million, and 17,844 metric tons of CO2 equivalent, respectively. Of the onsite energy (1.4E-03 kWh per gallon treated) 74% is process energy and 26% is non-process energy. Sixty-six percent of the process energy is consumed by the main treatment facility and high service distribution. When analyzing seasonal variations, the highest amount of process energy treated the largest amount of potable water with the maxiμm revealing four Btu used per gallon treated while utilizing 54% of the design capacity. Compared to the periods when the lowest amount of the design capacity was utilized, 32 - 33%, the facility consumed the seasonal high in energy, approximately 6.7 Btu per gallon treated. For the wastewater treatment and reclamation side, secondary treatment dominates all 3 categories by consuming 81,701,764 kBtu, 1.1 million, and 32,395 metric tons of CO2 equivalent. The total onsite energy was 2.79E-03 kWh per gallon treated, of which 43% was process energy, and the remainder was consumed by natural gas heating and `other non-process and process' energy, 34% and 23%, respectively. Most significantly during the months of April and May, when the influent flow of wastewater doubles and is diluted due to the addition of seasonal rain water, the amount of energy spent per gallon of treated wastewater decreases by 48% and 34% from the maximum (5.03E-03 kWh/gallon). By functioning closer to a forecasted design capacity, the efficiency of the potable water treatment facility could be dramatically improved. This can be achieved by implementing additional storage of ready-to-use potable water and/or by expanding the customer base and collaborating with other regional potable water utilities. For example, a county-wide approach to potable water planning falls into agreement with sustainable planning methods, providing regions of the county that have maximized treatment capacity of potable water and giving this region the opportunity to operate closer to the intended design capacity. On the wastewater treatment side, it is apparent that the more dense the BOD concentration in influent waters the more energy is spent in secondary treatment trying to remove it. Exploring more effective screening and pre-precipitation methods could also prove to save a significant amount in energy spent in the secondary treatment step, reducing the organic load prior to aeration. Coupling this with aeration blower and diffuser improvements can offer significant energy savings. Further water quality data and energy use data needs to be collected and analyzed on the individual wastewater treatment processes, especially regarding the impact and effectiveness of the preliminary and primary treatment steps on secondary treatment.
10 CFR 611.206 - Existing facilities.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 4 2010-01-01 2010-01-01 false Existing facilities. 611.206 Section 611.206 Energy... PROGRAM Facility/Funding Awards § 611.206 Existing facilities. The Secretary shall, in making awards to those manufacturers that have existing facilities, give priority to those facilities that are oldest or...
STS-116 payload egress training
2005-08-01
JSC2005-E-32736 (1 Aug. 2005) --- Crew trainer Bob Behrendsen briefs astronaut Mark L. Polansky, STS-116 commander, on the usage of a special pulley device, used to lower oneself from a trouble-plagued shuttle, during a training session in the Space Vehicle Mockup Facility at the Johnson Space Center. Polansky is attired in a training version of the shuttle launch and entry suit.
ERIC Educational Resources Information Center
Frohmberg, Katherine A.; Moffett, William A.
In order to study the effects of introducing an automated circulation system at Oberlin College, Ohio, data were collected from September 1978 until June 1982 on book availability, usage of library facilities, attitudes of library users toward the library, and the efficiency of circulation activities. Data collection methods included circulation…
The environmental control and life support system advanced automation project
NASA Technical Reports Server (NTRS)
Dewberry, Brandon S.
1991-01-01
The objective of the ECLSS Advanced Automation project includes reduction of the risk associated with the integration of new, beneficial software techniques. Demonstrations of this software to baseline engineering and test personnel will show the benefits of these techniques. The advanced software will be integrated into ground testing and ground support facilities, familiarizing its usage by key personnel.
Automated management of radioactive sources in Saudi Arabia
DOE Office of Scientific and Technical Information (OSTI.GOV)
Al-Kheliewi, Abdullah S.; Jamil, M. F.; Basar, M. R.
2014-09-30
For usage of radioactive substances, any facility has to register and take license from relevant authority of the country in which such facility is operating. In the Kingdom of Saudi Arabia (KSA), the authority for managing radioactive sources and providing licenses to organizations for its usage is the National Center of Radiation Protection (NCRP). This paper describes the system that automates registration and licensing process of the National Center of Radiation Protection. To provide 24×7 accesses to all the customers of NCRP, system is developed as web-based application that provide facility to online register, request license, renew license, check requestmore » status, view historical data and reports etc. and other features are provided as Electronic Services that would be accessible to users via internet. The system also was designed to streamline and optimize internal operations of NCRP besides providing ease of access to its customers by implementing a defined workflow through which every registration and license request will be routed. In addition to manual payment option, the system would also be integrated with SADAD (online payment system) that will avoid lengthy and cumbersome procedures associated with manual payment mechanism. Using SADAD payment option license fee could be paid through internet/ATM machine or branch of any designated bank, Payment will be instantly notified to NCRP hence delay in funds transfer and verification of invoice could be avoided, SADAD integration is discussed later in the document.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-19
... DEPARTMENT OF ENERGY DOE Response to Recommendation 2011-1 of the Defense Nuclear Facilities... Nuclear Facilities Safety Board, Office of Health, Safety and Security, U.S. Department of Energy, 1000... Department of Energy (DOE) acknowledges receipt of Defense Nuclear Facilities Safety Board (Board...
18 CFR 292.205 - Criteria for qualifying cogeneration facilities.
Code of Federal Regulations, 2013 CFR
2013-04-01
... useful thermal energy output of the facility must be no less than 5 percent of the total energy output... the facility plus one-half the useful thermal energy output, during the 12-month period beginning with... (B) If the useful thermal energy output is less than 15 percent of the total energy output of the...
18 CFR 292.205 - Criteria for qualifying cogeneration facilities.
Code of Federal Regulations, 2012 CFR
2012-04-01
... useful thermal energy output of the facility must be no less than 5 percent of the total energy output... the facility plus one-half the useful thermal energy output, during the 12-month period beginning with... (B) If the useful thermal energy output is less than 15 percent of the total energy output of the...
18 CFR 292.205 - Criteria for qualifying cogeneration facilities.
Code of Federal Regulations, 2011 CFR
2011-04-01
... useful thermal energy output of the facility must be no less than 5 percent of the total energy output... the facility plus one-half the useful thermal energy output, during the 12-month period beginning with... (B) If the useful thermal energy output is less than 15 percent of the total energy output of the...
18 CFR 292.205 - Criteria for qualifying cogeneration facilities.
Code of Federal Regulations, 2014 CFR
2014-04-01
... useful thermal energy output of the facility must be no less than 5 percent of the total energy output... the facility plus one-half the useful thermal energy output, during the 12-month period beginning with... (B) If the useful thermal energy output is less than 15 percent of the total energy output of the...
Legal requirements for human-health based appeals of wind energy projects in ontario.
Engel, Albert M
2014-01-01
In 2009, the government of the province of Ontario, Canada passed new legislation to promote the development of renewable energy facilities, including wind energy facilities in the province. Throughout the legislative process, concerns were raised with respect to the effect of wind energy facilities on human health. Ultimately, the government established setbacks and sound level limits for wind energy facilities and provided Ontario residents with the right to appeal the approval of a wind energy facility on the ground that engaging in the facility in accordance with its approval will cause serious harm to human health. The first approval of a wind facility under the new legislation was issued in 2010 and since then, Ontario's Environmental Review Tribunal as well as Ontario's courts has been considering evidence proffered by appellants seeking revocation of approvals on the basis of serious harm to human health. To date, the evidence has been insufficient to support the revocation of a wind facility approval. This article reviews the legal basis for the dismissal of human-health based appeals.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xu, Tengfang; Piette, Mary Ann
2004-08-05
The original scope of work was to obtain and analyze existing and emerging data in four states: California, Florida, New York, and Wisconsin. The goal of this data collection was to deliver a baseline database or recommendations for such a database that could possibly contain window and daylighting features and energy performance characteristics of Kindergarten through 12th grade (K-12) school buildings (or those of classrooms when available). In particular, data analyses were performed based upon the California Commercial End-Use Survey (CEUS) databases to understand school energy use, features of window glazing, and availability of daylighting in California K-12 schools. Themore » outcomes from this baseline task can be used to assist in establishing a database of school energy performance, assessing applications of existing technologies relevant to window and daylighting design, and identifying future R&D needs. These are in line with the overall project goals as outlined in the proposal. Through the review and analysis of this data, it is clear that there are many compounding factors impacting energy use in K-12 school buildings in the U.S., and that there are various challenges in understanding the impact of K-12 classroom energy use associated with design features of window glazing and skylight. First, the energy data in the existing CEUS databases has, at most, provided the aggregated electricity and/or gas usages for the building establishments that include other school facilities on top of the classroom spaces. Although the percentage of classroom floor area in schools is often available from the databases, there is no additional information that can be used to quantitatively segregate the EUI for classroom spaces. In order to quantify the EUI for classrooms, sub-metering of energy usage by classrooms must be obtained. Second, magnitudes of energy use for electricity lighting are not attainable from the existing databases, nor are the lighting levels contributed by artificial lighting or daylight. It is impossible to reasonably estimate the lighting energy consumption for classroom areas in the sample of schools studied in this project. Third, there are many other compounding factors that may as well influence the overall classroom energy use, e.g., ventilation, insulation, system efficiency, occupancy, control, schedules, and weather. Fourth, although we have examined the school EUI grouped by various factors such as climate zones, window and daylighting design features from the California databases, no statistically significant associations can be identified from the sampled California K-12 schools in the current California CEUS. There are opportunities to expand such analyses by developing and including more powerful CEUS databases in the future. Finally, a list of parameters is recommended for future database development and for use of future investigation in K-12 classroom energy use, window and skylight design, and possible relations between them. Some of the key parameters include: (1) Energy end use data for lighting systems, classrooms, and schools; (2) Building design and operation including features for windows and daylighting; and (3) Other key parameters and information that would be available to investigate overall energy uses, building and systems design, their operation, and services provided.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1995-03-17
This report summarizes all work for the Energy Survey of Army Industrial Facilities, Energy Engineering Analysis Program (EEAP) at the Western Area Demilitarization Facility (WADF) of the Hawthorne Army Ammunition Plant (HWAAP), Hawthorne, Nevada, authorized under Contract No. DACA03-92-C-0155 with the U.S. Army Corps of Engineers, Sacramento District, California. The purpose of this energy survey is to develop a set of projects and actions that will reduce energy consumption and operating costs of selected facilities at the WADF. A preliminary inspection of facilities at WADF by Keller Gannon that identified potential retrofit opportunities was submitted as the EEAP Study andmore » Criteria Review in December 1993. This document formed the basis of the Detailed Scope of Work for this study. Facilities included in the survey and study, together with operational status, are listed in Table 1 - 1. The complete scope of work appears in Appendix.« less
Evaluating Past and Future USCG Use of Ohmsett Test Facility
2016-10-01
and Renewable Energy Test Facility, that was previously known as a fully capitalized acronym, Ohmsett. This facility is located on the U.S. Naval...Oil Spill Response Research and Renewable Energy Test Facility, that was previously known as a fully capitalized acronym, Ohmsett. This facility is...Incident Management Systems NSF National Strike Force NWS Naval Weapons Station Ohmsett National Oil Spill Response Research and Renewable Energy
A Framework for Understanding and Generating Integrated Solutions for Residential Peak Energy Demand
Buys, Laurie; Vine, Desley; Ledwich, Gerard; Bell, John; Mengersen, Kerrie; Morris, Peter; Lewis, Jim
2015-01-01
Supplying peak energy demand in a cost effective, reliable manner is a critical focus for utilities internationally. Successfully addressing peak energy concerns requires understanding of all the factors that affect electricity demand especially at peak times. This paper is based on past attempts of proposing models designed to aid our understanding of the influences on residential peak energy demand in a systematic and comprehensive way. Our model has been developed through a group model building process as a systems framework of the problem situation to model the complexity within and between systems and indicate how changes in one element might flow on to others. It is comprised of themes (social, technical and change management options) networked together in a way that captures their influence and association with each other and also their influence, association and impact on appliance usage and residential peak energy demand. The real value of the model is in creating awareness, understanding and insight into the complexity of residential peak energy demand and in working with this complexity to identify and integrate the social, technical and change management option themes and their impact on appliance usage and residential energy demand at peak times. PMID:25807384
Buys, Laurie; Vine, Desley; Ledwich, Gerard; Bell, John; Mengersen, Kerrie; Morris, Peter; Lewis, Jim
2015-01-01
Supplying peak energy demand in a cost effective, reliable manner is a critical focus for utilities internationally. Successfully addressing peak energy concerns requires understanding of all the factors that affect electricity demand especially at peak times. This paper is based on past attempts of proposing models designed to aid our understanding of the influences on residential peak energy demand in a systematic and comprehensive way. Our model has been developed through a group model building process as a systems framework of the problem situation to model the complexity within and between systems and indicate how changes in one element might flow on to others. It is comprised of themes (social, technical and change management options) networked together in a way that captures their influence and association with each other and also their influence, association and impact on appliance usage and residential peak energy demand. The real value of the model is in creating awareness, understanding and insight into the complexity of residential peak energy demand and in working with this complexity to identify and integrate the social, technical and change management option themes and their impact on appliance usage and residential energy demand at peak times.
18 CFR 292.204 - Criteria for qualifying small power production facilities.
Code of Federal Regulations, 2010 CFR
2010-04-01
... primary energy source of the facility must be biomass, waste, renewable resources, geothermal resources... FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY REGULATIONS UNDER THE PUBLIC UTILITY REGULATORY... production facilities that use the same energy resource, are owned by the same person(s) or its affiliates...
ERIC Educational Resources Information Center
Federal Energy Administration, Washington, DC.
The American Society of Heating, Refrigerating, and Air Conditioning Engineers (ASHRAE), has developed a document governing energy usage in all types of new construction: ASHRAE Standard 90-75: Energy Conservation in New Building Design (ASHRAE 90). To lay the foundation for an evaluation of ASHRAE 90, the Federal Energy Administration (FEA)…
Energy Awareness and Scheduling in Mobile Devices and High End Computing
ERIC Educational Resources Information Center
Pawaskar, Sachin S.
2013-01-01
In the context of the big picture as energy demands rise due to growing economies and growing populations, there will be greater emphasis on sustainable supply, conservation, and efficient usage of this vital resource. Even at a smaller level, the need for minimizing energy consumption continues to be compelling in embedded, mobile, and server…
Challenge Students to Design an Energy-Efficient Home
ERIC Educational Resources Information Center
Griffith, Jack
2008-01-01
This article presents an activity that gives students a practical understanding of how much energy the average home consumes and wastes, and shows how the construction technologies used in home design affect overall energy usage. In this activity, students will outline the cost of a home's electrical system, give a breakdown of how much power the…
Textiles & Clothing Curriculum Guide. Energy and the Family.
ERIC Educational Resources Information Center
Davidson, Jane S.; Morris, Carol
This curriculum guide on textiles and clothing, covering one of the five content areas of the Energy and Family Curriculum Guide, has been designed to provide learning experiences and identify resources that can be used to develop units of study related to energy usage and conservation. The guide is intended for use in comprehensive courses of…
Housing & Home Furnishings Curriculum Guide. Energy and the Family.
ERIC Educational Resources Information Center
Davidson, Jane S.; Morris, Carol
This curriculum guide on housing and home furnishings, covering one of the five content areas of the Energy and the Family Curriculum Guide, has been designed to provide learning experiences and identify resources that can be used to develop units of study related to energy usage and conservation. The guide is intended for use in comprehensive…
Evaluation of the "Lose Your Excuse" Public Service Advertising Campaign for Tweens to Save Energy
ERIC Educational Resources Information Center
Bertrand, Jane T.; Goldman, Patty; Zhivan, Natalia; Agyeman, Yaw; Barber, Erin
2011-01-01
This study evaluates the 2008-2009 "Lose your Excuse" public service advertising (PSA) campaign on energy efficiency targeting 8- to 12-year-olds, intended to increase knowledge, foster proactive attitudes, and change energy usage behaviors. Baseline and two follow-up surveys were conducted with online samples representative of the national…
Biomass energy : the new frontier
John I. Zerbe
2006-01-01
We can have the greatest direct impact on petroleum and natural gas fuel usage by burning or gasifying wood for space heat, process energy and power. One alternative source that is available and underused is surplus wood. Certainly wood that is suitable for use in more valuable products should not be diverted to energy use that provides less income; however, other wood...
News from the ESO Science Archive Facility
NASA Astrophysics Data System (ADS)
Dobrzycki, A.; Arnaboldi, M.; Bierwirth, T.; Boelter, M.; Da Rocha, C.; Delmotte, N.; Forchì, V.; Fourniol, N.; klein Gebbinck, M.; Lange, U.; Mascetti, L.; Micol, A.; Moins, C.; Munte, C.; Pluciennik, C.; Retzlaff, J.; Romaniello, M.; Rosse, N.; Sequeiros, I. V.; Vuong, M.-H.; Zampieri, S.
2015-09-01
ESO Science Archive Facility (SAF) - one of the world's biggest astronomical archives - combines two roles: operational (ingest, tallying, safekeeping and distribution to observers of raw data taken with ESO telescopes and processed data generated both internally and externally) and scientific (publication and delivery of all flavours of data to external users). This paper presents the “State of the SAF.” SAF, as a living entity, is constantly implementing new services and upgrading the existing ones. We present recent and future developments related to the Archive's Request Handler and metadata handling as well as performance and usage statistics and trends. We also discuss the current and future datasets on offer at SAF.
Final Report: Hydrogen Production Pathways Cost Analysis (2013 – 2016)
DOE Office of Scientific and Technical Information (OSTI.GOV)
James, Brian David; DeSantis, Daniel Allan; Saur, Genevieve
This report summarizes work conducted under a three year Department of Energy (DOE) funded project to Strategic Analysis, Inc. (SA) to analyze multiple hydrogen (H 2) production technologies and project their corresponding levelized production cost of H 2. The analysis was conducted using the H2A Hydrogen Analysis Tool developed by the DOE and National Renewable Energy Laboratory (NREL). The project was led by SA but conducted in close collaboration with the NREL and Argonne National Laboratory (ANL). In-depth techno-economic analysis (TEA) of five different H 2 production methods was conducted. These TEAs developed projections for capital costs, fuel/feedstock usage, energymore » usage, indirect capital costs, land usage, labor requirements, and other parameters, for each H 2 production pathway, and use the resulting cost and system parameters as inputs into the H2A discounted cash flow model to project the production cost of H 2 ($/kgH 2). Five technologies were analyzed as part of the project and are summarized in this report: Proton Exchange Membrane technology (PEM), High temperature solid oxide electrolysis cell technology (SOEC), Dark fermentation of biomass for H 2 production, H 2 production via Monolithic Piston-Type Reactors with rapid swing reforming and regeneration reactions, and Reformer-Electrolyzer-Purifier (REP) technology developed by Fuel Cell Energy, Inc. (FCE).« less
Zhou, Zhi; de Bedout, Juan Manuel; Kern, John Michael; Biyik, Emrah; Chandra, Ramu Sharat
2013-01-22
A system for optimizing customer utility usage in a utility network of customer sites, each having one or more utility devices, where customer site is communicated between each of the customer sites and an optimization server having software for optimizing customer utility usage over one or more networks, including private and public networks. A customer site model for each of the customer sites is generated based upon the customer site information, and the customer utility usage is optimized based upon the customer site information and the customer site model. The optimization server can be hosted by an external source or within the customer site. In addition, the optimization processing can be partitioned between the customer site and an external source.
Security in Wireless Sensor Networks Employing MACGSP6
ERIC Educational Resources Information Center
Nitipaichit, Yuttasart
2010-01-01
Wireless Sensor Networks (WSNs) have unique characteristics which constrain them; including small energy stores, limited computation, and short range communication capability. Most traditional security algorithms use cryptographic primitives such as Public-key cryptography and are not optimized for energy usage. Employing these algorithms for the…
NASA Technical Reports Server (NTRS)
Braman, Julia M. B.; Wagner, David A.
2010-01-01
Safe human exploration in space missions requires careful management of limited resources such as breathable air and stored electrical energy. Daily activities for astronauts must be carefully planned with respect to such resources, and usage must be monitored as activities proceed to ensure that they can be completed while maintaining safe resource margins. Such planning and monitoring can be complex because they depend on models of resource usage, the activities being planned, and uncertainties. This paper describes a system - and the technology behind it - for energy management of the NASA-Johnson Space Center's Multi-Mission Space Exploration Vehicles (SEV), that provides, in an onboard advisory mode, situational awareness to astronauts and real-time guidance to mission operators. This new capability was evaluated during this year's Desert RATS (Research and Technology Studies) planetary exploration analog test in Arizona. This software aided ground operators and crew members in modifying the day s activities based on the real-time execution of the plan and on energy data received from the rovers.
Code of Federal Regulations, 2012 CFR
2012-01-01
... over nuclear facilities and materials under the Atomic Energy Act. 8.4 Section 8.4 Energy NUCLEAR... nuclear facilities and materials under the Atomic Energy Act. (a) By virtue of the Atomic Energy Act of... Atomic Energy Act of 1954 sets out a pattern for licensing and regulation of certain nuclear materials...
Code of Federal Regulations, 2010 CFR
2010-01-01
... over nuclear facilities and materials under the Atomic Energy Act. 8.4 Section 8.4 Energy NUCLEAR... nuclear facilities and materials under the Atomic Energy Act. (a) By virtue of the Atomic Energy Act of... Atomic Energy Act of 1954 sets out a pattern for licensing and regulation of certain nuclear materials...
Code of Federal Regulations, 2011 CFR
2011-01-01
... over nuclear facilities and materials under the Atomic Energy Act. 8.4 Section 8.4 Energy NUCLEAR... nuclear facilities and materials under the Atomic Energy Act. (a) By virtue of the Atomic Energy Act of... Atomic Energy Act of 1954 sets out a pattern for licensing and regulation of certain nuclear materials...
NASA Technical Reports Server (NTRS)
Parrish, R. V.; Dieudonne, J. E.; Filippas, T. A.
1971-01-01
An algorithm employing a modified sequential random perturbation, or creeping random search, was applied to the problem of optimizing the parameters of a high-energy beam transport system. The stochastic solution of the mathematical model for first-order magnetic-field expansion allows the inclusion of state-variable constraints, and the inclusion of parameter constraints allowed by the method of algorithm application eliminates the possibility of infeasible solutions. The mathematical model and the algorithm were programmed for a real-time simulation facility; thus, two important features are provided to the beam designer: (1) a strong degree of man-machine communication (even to the extent of bypassing the algorithm and applying analog-matching techniques), and (2) extensive graphics for displaying information concerning both algorithm operation and transport-system behavior. Chromatic aberration was also included in the mathematical model and in the optimization process. Results presented show this method as yielding better solutions (in terms of resolutions) to the particular problem than those of a standard analog program as well as demonstrating flexibility, in terms of elements, constraints, and chromatic aberration, allowed by user interaction with both the algorithm and the stochastic model. Example of slit usage and a limited comparison of predicted results and actual results obtained with a 600 MeV cyclotron are given.
10 CFR 1004.3 - Public reading facilities and policy on contractor records.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 4 2012-01-01 2012-01-01 false Public reading facilities and policy on contractor records. 1004.3 Section 1004.3 Energy DEPARTMENT OF ENERGY (GENERAL PROVISIONS) FREEDOM OF INFORMATION § 1004.3 Public reading facilities and policy on contractor records. (a) The DOE Headquarters will maintain, in the public reading facilities, the...
10 CFR 1004.3 - Public reading facilities and policy on contractor records.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 4 2011-01-01 2011-01-01 false Public reading facilities and policy on contractor records. 1004.3 Section 1004.3 Energy DEPARTMENT OF ENERGY (GENERAL PROVISIONS) FREEDOM OF INFORMATION § 1004.3 Public reading facilities and policy on contractor records. (a) The DOE Headquarters will maintain, in the public reading facilities, the...
10 CFR 1004.3 - Public reading facilities and policy on contractor records.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 4 2013-01-01 2013-01-01 false Public reading facilities and policy on contractor records. 1004.3 Section 1004.3 Energy DEPARTMENT OF ENERGY (GENERAL PROVISIONS) FREEDOM OF INFORMATION § 1004.3 Public reading facilities and policy on contractor records. (a) The DOE Headquarters will maintain, in the public reading facilities, the...
10 CFR 1004.3 - Public reading facilities and policy on contractor records.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 4 2014-01-01 2014-01-01 false Public reading facilities and policy on contractor records. 1004.3 Section 1004.3 Energy DEPARTMENT OF ENERGY (GENERAL PROVISIONS) FREEDOM OF INFORMATION § 1004.3 Public reading facilities and policy on contractor records. (a) The DOE Headquarters will maintain, in the public reading facilities, the...
Survey of EPA facilities for solar thermal energy applications
NASA Technical Reports Server (NTRS)
Nelson, E. V.; Overly, P. T.; Bell, D. M.
1980-01-01
A study was done to assess the feasibility of applying solar thermal energy systems to EPA facilities. A survey was conducted to determine those EPA facilities where solar energy could best be used. These systems were optimized for each specific application and the system/facility combinations were ranked on the basis of greatest cost effectiveness.
Kumar, Vinod; Afrin, Samia; Ortega, Jesus; ...
2013-09-01
A prototype of a concentrating solar collector (CSC) receiver was designed, built, and evaluated on-sun at the University of Texas at El Paso in El Paso, TX. This prototype receiver consists of two parabolic trough-reflectors but, in principle, the design can be efficiently extended to multiple units for achieving a higher temperature throughput. Each reflector has a vacuum tube collector at the focal point of the trough. The solar collector system was combined with a single-tank thermocline thermal energy storage (TES) for off-solar thermal usage. The main goal of this study is to develop an advanced solar hot water systemmore » for most residential applications. The focus of this study is to investigate the feasibility and performance of the solar thermal system by employing the recent advancement in the TES—a thermocline based TES—system for the concentrating solar power technologies developed by the Sandia National Laboratories and National Renewable Energy Laboratories for electricity production. A CSC when combined with TES has potential to provide uninterrupted thermal energy for most residential usages. This paper presents a detailed description of prototype design and materials required. The thermal energy storage tank utilizes an insulated 170 l (45 gal) galvanized steel tank. In order to maintain thermocline in the TES tank, with hot water on top and cold water at the bottom, two plate distributors are installed in the tank. The data showed a significant enhancement in thermal energy generation. This thermocline based single tank presented a thermal energy storage potential for at least three days (with diminishing storage capacity) that test were performed. The whole prototype was made for approximately USD 355 (excludes any labor costs) and hence also has strong potential for supplying clean thermal energy in most developing countries. As a result, tests of the prototype were conducted in November 2011.« less
TEP Power Partners Project [Tucson Electric Power
DOE Office of Scientific and Technical Information (OSTI.GOV)
None, None
2014-02-06
The Arizona Governor’s Office of Energy Policy, in partnership with Tucson Electric Power (TEP), Tendril, and Next Phase Energy (NPE), formed the TEP Power Partners pilot project to demonstrate how residential customers could access their energy usage data and third party applications using data obtained from an Automatic Meter Reading (AMR) network. The project applied for and was awarded a Smart Grid Data Access grant through the U.S. Department of Energy. The project participants’ goal for Phase I is to actively engage 1,700 residential customers to demonstrate sustained participation, reduction in energy usage (kWh) and cost ($), and measure relatedmore » aspects of customer satisfaction. This Demonstration report presents a summary of the findings, effectiveness, and customer satisfaction with the 15-month TEP Power Partners pilot project. The objective of the program is to provide residential customers with energy consumption data from AMR metering and empower these participants to better manage their electricity use. The pilot recruitment goals included migrating 700 existing customers from the completed Power Partners Demand Response Load Control Project (DRLC), and enrolling 1,000 new participants. Upon conclusion of the project on November 19, 2013; 1,390 Home Area Networks (HANs) were registered; 797 new participants installed a HAN; Survey respondents’ are satisfied with the program and found value with a variety of specific program components; Survey respondents report feeling greater control over their energy usage and report taking energy savings actions in their homes after participating in the program; On average, 43 % of the participants returned to the web portal monthly and 15% returned weekly; and An impact evaluation was completed by Opinion Dynamics and found average participant savings for the treatment period1 to be 2.3% of their household use during this period.2 In total, the program saved 163 MWh in the treatment period of 2013.« less
Garrido-Baserba, Manel; Sobhani, Reza; Asvapathanagul, Pitiporn; McCarthy, Graham W; Olson, Betty H; Odize, Victory; Al-Omari, Ahmed; Murthy, Sudhir; Nifong, Andrea; Godwin, Johnnie; Bott, Charles B; Stenstrom, Michael K; Shaw, Andrew R; Rosso, Diego
2017-03-15
This research systematically studied the behavior of aeration diffuser efficiency over time, and its relation to the energy usage per diffuser. Twelve diffusers were selected for a one year fouling study. Comprehensive aeration efficiency projections were carried out in two WRRFs with different influent rates, and the influence of operating conditions on aeration diffusers' performance was demonstrated. This study showed that the initial energy use, during the first year of operation, of those aeration diffusers located in high rate systems (with solids retention time - SRT-less than 2 days) increased more than 20% in comparison to the conventional systems (2 > SRT). Diffusers operating for three years in conventional systems presented the same fouling characteristics as those deployed in high rate processes for less than 15 months. A new procedure was developed to accurately project energy consumption on aeration diffusers; including the impacts of operation conditions, such SRT and organic loading rate, on specific aeration diffusers materials (i.e. silicone, polyurethane, EPDM, ceramic). Furthermore, it considers the microbial colonization dynamics, which successfully correlated with the increase of energy consumption (r 2 :0.82 ± 7). The presented energy model projected the energy costs and the potential savings for the diffusers after three years in operation in different operating conditions. Whereas the most efficient diffusers provided potential costs spanning from 4900 USD/Month for a small plant (20 MGD, or 74,500 m 3 /d) up to 24,500 USD/Month for a large plant (100 MGD, or 375,000 m 3 /d), other diffusers presenting less efficiency provided spans from 18,000USD/Month for a small plant to 90,000 USD/Month for large plants. The aim of this methodology is to help utilities gain more insight into process mechanisms and design better energy efficiency strategies at existing facilities to reduce energy consumption. Copyright © 2016 Elsevier Ltd. All rights reserved.
10 CFR 55.46 - Simulation facilities.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 2 2012-01-01 2012-01-01 false Simulation facilities. 55.46 Section 55.46 Energy NUCLEAR... Simulation facilities. (a) General. This section addresses the use of a simulation facility for the... applicants for operator and senior operator licenses. (b) Commission-approved simulation facilities and...
10 CFR 55.46 - Simulation facilities.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 2 2010-01-01 2010-01-01 false Simulation facilities. 55.46 Section 55.46 Energy NUCLEAR... Simulation facilities. (a) General. This section addresses the use of a simulation facility for the... applicants for operator and senior operator licenses. (b) Commission-approved simulation facilities and...
10 CFR 55.46 - Simulation facilities.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 2 2011-01-01 2011-01-01 false Simulation facilities. 55.46 Section 55.46 Energy NUCLEAR... Simulation facilities. (a) General. This section addresses the use of a simulation facility for the... applicants for operator and senior operator licenses. (b) Commission-approved simulation facilities and...
10 CFR 55.46 - Simulation facilities.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 2 2013-01-01 2013-01-01 false Simulation facilities. 55.46 Section 55.46 Energy NUCLEAR... Simulation facilities. (a) General. This section addresses the use of a simulation facility for the... applicants for operator and senior operator licenses. (b) Commission-approved simulation facilities and...
10 CFR 55.46 - Simulation facilities.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 2 2014-01-01 2014-01-01 false Simulation facilities. 55.46 Section 55.46 Energy NUCLEAR... Simulation facilities. (a) General. This section addresses the use of a simulation facility for the... applicants for operator and senior operator licenses. (b) Commission-approved simulation facilities and...
10 CFR 26.123 - Testing facility capabilities.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 1 2014-01-01 2014-01-01 false Testing facility capabilities. 26.123 Section 26.123 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Licensee Testing Facilities § 26.123 Testing facility capabilities. Each licensee testing facility shall have the capability, at the same...
10 CFR 26.123 - Testing facility capabilities.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 1 2012-01-01 2012-01-01 false Testing facility capabilities. 26.123 Section 26.123 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Licensee Testing Facilities § 26.123 Testing facility capabilities. Each licensee testing facility shall have the capability, at the same...
10 CFR 26.123 - Testing facility capabilities.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 1 2013-01-01 2013-01-01 false Testing facility capabilities. 26.123 Section 26.123 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Licensee Testing Facilities § 26.123 Testing facility capabilities. Each licensee testing facility shall have the capability, at the same...
10 CFR 26.123 - Testing facility capabilities.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 1 2011-01-01 2011-01-01 false Testing facility capabilities. 26.123 Section 26.123 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Licensee Testing Facilities § 26.123 Testing facility capabilities. Each licensee testing facility shall have the capability, at the same...
10 CFR 26.123 - Testing facility capabilities.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 1 2010-01-01 2010-01-01 false Testing facility capabilities. 26.123 Section 26.123 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Licensee Testing Facilities § 26.123 Testing facility capabilities. Each licensee testing facility shall have the capability, at the same...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stewart, James
Strategic energy management (SEM) focuses on achieving energy-efficiency improvements through systematic and planned changes in facility operations, maintenance, and behaviors (OM&B) and capital equipment upgrades in large energy-using facilities, including industrial buildings, commercial buildings, and multi-facility organizations such as campuses or communities. Facilities can institute a spectrum of SEM actions, ranging from a simple process for regularly identifying energy-savings actions, to establishing a formal, third-party recognized or certified SEM framework for continuous improvement of energy performance. In general, SEM programs that would be considered part of a utility program will contain a set of energy-reducing goals, principles, and practices emphasizingmore » continuous improvements in energy performance or savings through energy management and an energy management system (EnMS).« less
Seals Flow Code Development 1993
NASA Technical Reports Server (NTRS)
Liang, Anita D. (Compiler); Hendricks, Robert C. (Compiler)
1994-01-01
Seals Workshop of 1993 code releases include SPIRALI for spiral grooved cylindrical and face seal configurations; IFACE for face seals with pockets, steps, tapers, turbulence, and cavitation; GFACE for gas face seals with 'lift pad' configurations; and SCISEAL, a CFD code for research and design of seals of cylindrical configuration. GUI (graphical user interface) and code usage was discussed with hands on usage of the codes, discussions, comparisons, and industry feedback. Other highlights for the Seals Workshop-93 include environmental and customer driven seal requirements; 'what's coming'; and brush seal developments including flow visualization, numerical analysis, bench testing, T-700 engine testing, tribological pairing and ceramic configurations, and cryogenic and hot gas facility brush seal results. Also discussed are seals for hypersonic engines and dynamic results for spiral groove and smooth annular seals.
Fog-computing concept usage as means to enhance information and control system reliability
NASA Astrophysics Data System (ADS)
Melnik, E. V.; Klimenko, A. B.; Ivanov, D. Ya
2018-05-01
This paper focuses on the reliability issue of information and control systems (ICS). The authors propose using the elements of the fog-computing concept to enhance the reliability function. The key idea of fog-computing is to shift computations to the fog-layer of the network, and thus to decrease the workload of the communication environment and data processing components. As for ICS, workload also can be distributed among sensors, actuators and network infrastructure facilities near the sources of data. The authors simulated typical workload distribution situations for the “traditional” ICS architecture and for the one with fogcomputing concept elements usage. The paper contains some models, selected simulation results and conclusion about the prospects of the fog-computing as a means to enhance ICS reliability.
Locations and attributes of wind turbines in Colorado, 2009
Carr, Natasha B.; Diffendorfer, Jay E.; Fancher, Tammy S.; Latysh, Natalie E.; Leib, Kenneth J.; Matherne, Anne-Marie; Turner, Christine
2011-01-01
The Colorado wind-turbine data series provides geospatial data for all wind turbines established within the State as of August 2009. Attributes specific to each turbine include: turbine location, manufacturer and model, rotor diameter, hub height, rotor height, potential megawatt output, land ownership, and county. Wind energy facility data for each turbine include: facility name, facility power capacity, number of turbines associated with each facility to date, facility developer, facility ownership, year the facility went online, and development status of wind facility. Turbine locations were derived from August 2009 1-meter true-color aerial photographs produced by the National Agriculture Imagery Program; the photographs have a positional accuracy of about + or - 5 meters. The location of turbines under construction during August 2009 likely will be less accurate than the location of existing turbines. This data series contributes to an Online Interactive Energy Atlas currently (2011) in development by the U.S. Geological Survey. The Energy Atlas will synthesize data on existing and potential energy development in Colorado and New Mexico and will include additional natural resource data layers. This information may be used by decisionmakers to evaluate and compare the potential benefits and tradeoffs associated with different energy development strategies or scenarios. Interactive maps, downloadable data layers, comprehensive metadata, and decision-support tools will be included in the Energy Atlas. The format of the Energy Atlas will facilitate the integration of information about energy with key terrestrial and aquatic resources for evaluating resource values and minimizing risks from energy development.
Locations and attributes of wind turbines in New Mexico, 2009
Carr, Natasha B.; Diffendorfer, Jay E.; Fancher, Tammy S.; Latysh, Natalie E.; Leib, Kenneth J.; Matherne, Anne-Marie; Turner, Christine
2011-01-01
The New Mexico wind-turbine data series provides geospatial data for all wind turbines established within the State as of August 2009. Attributes specific to each turbine include: turbine location, manufacturer and model, rotor diameter, hub height, rotor height, potential megawatt output, land ownership, and county. Wind energy facility data for each turbine include: facility name, facility power capacity, number of turbines associated with each facility to date, facility developer, facility ownership, year the facility went online, and development status of wind facility. Turbine locations were derived from 1-meter August 2009 true-color aerial photographs produced by the National Agriculture Imagery Program; the photographs have a positional accuracy of about + or - 5 meters. The location of turbines under construction during August 2009 likely will be less accurate than the location of existing turbines. This data series contributes to an Online Interactive Energy Atlas currently (2011) in development by the U.S. Geological Survey. The Energy Atlas will synthesize data on existing and potential energy development in Colorado and New Mexico and will include additional natural resource data layers. This information may be used by decisionmakers to evaluate and compare the potential benefits and tradeoffs associated with different energy development strategies or scenarios. Interactive maps, downloadable data layers, comprehensive metadata, and decision-support tools will be included in the Energy Atlas. The format of the Energy Atlas will facilitate the integration of information about energy with key terrestrial and aquatic resources for evaluating resource values and minimizing risks from energy development.
An intertemporal decision framework for electrochemical energy storage management
NASA Astrophysics Data System (ADS)
He, Guannan; Chen, Qixin; Moutis, Panayiotis; Kar, Soummya; Whitacre, Jay F.
2018-05-01
Dispatchable energy storage is necessary to enable renewable-based power systems that have zero or very low carbon emissions. The inherent degradation behaviour of electrochemical energy storage (EES) is a major concern for both EES operational decisions and EES economic assessments. Here, we propose a decision framework that addresses the intertemporal trade-offs in terms of EES degradation by deriving, implementing and optimizing two metrics: the marginal benefit of usage and the average benefit of usage. These metrics are independent of the capital cost of the EES system, and, as such, separate the value of EES use from the initial cost, which provides a different perspective on storage valuation and operation. Our framework is proved to produce the optimal solution for EES life-cycle profit maximization. We show that the proposed framework offers effective ways to assess the economic values of EES, to make investment decisions for various applications and to inform related subsidy policies.
Economic and life cycle assessments of biomass utilization for bioenergy products
Liu, Weiguo; Wang, Jingxin; Richard, Tom L.; ...
2017-05-04
A modeling process was developed to examine the economic and environmental benefits of utilizing energy crops for biofuels and bioproducts. Three energy crops (hybrid willow, switchgrass and miscanthus) that can potentially grow on marginal agricultural land or abandoned mine land in the northeastern United States were considered in the analytical process for the production of biofuels, biopower and pellet fuel. The supply chain components for both the economic analysis and life cycle modeling processes included feedstock establishment, harvest, transportation, storage, preprocessing, conversion, distribution and final usage. Sensitivity analysis was also conducted to assess the effects of energy crop yield, transportationmore » distance, conversion rate, facility capacity and internal rate of return (IRR) on the production of bioenergy products. The required selling price (RSP) ranged from $ 7.7/GJ to $ 47.9/GJ for different bioproducts. The production of biopower had the highest RSP and pellet fuel had the lowest. The results also indicated that bioenergy production using hybrid willow demonstrated lower RSP than the two perennial grass feedstocks. Pellet production presented the lowest greenhouse gas (GHG) emissions (less than 10 kg CO 2 eq per 1,000 MJ) and fossil energy consumption (less than 150 MJ per 1,000 MJ). The production of biofuel resulted in the highest GHG emissions. Sensitivity analysis indicated that IRR was the most sensitive factor to RSP and followed by conversion rate for biofuel and biopower production. As a result, conversion rate and transportation distance of feedstock presented a significant effect on environmental impacts during the production of the bioproducts.« less
Economic and life cycle assessments of biomass utilization for bioenergy products
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Weiguo; Wang, Jingxin; Richard, Tom L.
A modeling process was developed to examine the economic and environmental benefits of utilizing energy crops for biofuels and bioproducts. Three energy crops (hybrid willow, switchgrass and miscanthus) that can potentially grow on marginal agricultural land or abandoned mine land in the northeastern United States were considered in the analytical process for the production of biofuels, biopower and pellet fuel. The supply chain components for both the economic analysis and life cycle modeling processes included feedstock establishment, harvest, transportation, storage, preprocessing, conversion, distribution and final usage. Sensitivity analysis was also conducted to assess the effects of energy crop yield, transportationmore » distance, conversion rate, facility capacity and internal rate of return (IRR) on the production of bioenergy products. The required selling price (RSP) ranged from $ 7.7/GJ to $ 47.9/GJ for different bioproducts. The production of biopower had the highest RSP and pellet fuel had the lowest. The results also indicated that bioenergy production using hybrid willow demonstrated lower RSP than the two perennial grass feedstocks. Pellet production presented the lowest greenhouse gas (GHG) emissions (less than 10 kg CO 2 eq per 1,000 MJ) and fossil energy consumption (less than 150 MJ per 1,000 MJ). The production of biofuel resulted in the highest GHG emissions. Sensitivity analysis indicated that IRR was the most sensitive factor to RSP and followed by conversion rate for biofuel and biopower production. As a result, conversion rate and transportation distance of feedstock presented a significant effect on environmental impacts during the production of the bioproducts.« less
Words vs. deeds: Americans' energy concerns and implementation of green energy policies
NASA Astrophysics Data System (ADS)
Brinker, Garrett C.
As the effects of climate change become increasingly clear, nations, international organizations, and corporations are working together to help mitigate these negative effects before they become irreversible. The United States, as the world's largest emitter per capita, has a responsibility to take quick and decisive action to decrease carbon emissions. And while an overwhelming majority of Americans believe that green energy policies are the right step forward, few have taken meaningful steps to actually implement these policies. Green and energy efficient technologies such as hybrid and electric cars, smart meters, and solar panels---technologies that would reduce our carbon footprint---are currently purchased or used by very few households. There is a clear gap between our words and deeds. Using the University of Texas at Austin Energy Poll dataset, this paper examines this gap and analyzes how income may influence what people say, versus how they act, seeking to better understand how income influences peoples' energy behaviors. Previous literature suggests that income has proven to be an inconsistent measure of concern for energy use. Through two OLS models, this paper finds that income is negatively correlated with Americans' concern for energy usage, while finding that there is a positive correlation between income and Americans' implementation of energy efficient technologies. Further, there is a nonlinear relationship between income groups and how Americans both think about their energy usage and actually implement more energy efficient measures.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Henderson, C.; Wilhelm, J.P.
1979-08-01
Measures that offer promise of efficiency improvements or economy in energy usage in rail passenger transportation are identified and described; the future of rail passenger transportation in the US is discussed; and possible future roles of Federal agencies are discussed.
Energy Efficient Storage and Transfer of Cryogens
NASA Technical Reports Server (NTRS)
Fesmire, James E.
2013-01-01
Cryogenics is globally linked to energy generation, storage, and usage. Thermal insulation systems research and development is an enabling part of NASA's technology goals for Space Launch and Exploration. New thermal testing methodologies and materials are being transferred to industry for a wide range of commercial applications.
NASA Technical Reports Server (NTRS)
Edde, H.
1981-01-01
The collection and dissemination of thermal energy storage (TES) system technology for the pulp and paper industry with the intent of reducing fossil fuel usage is discussed. The study plan is described and a description presented of example TES systems.
Senior High School Students' Preference and Reasoning Modes about Nuclear Energy Use.
ERIC Educational Resources Information Center
Yang, Fang-Ying; Anderson, O. Roger
2003-01-01
Examines senior high school students' cognitive orientation toward scientific or social information, designated as information preference, and associated preferential reasoning modes when presented with an environmental issue concerning nuclear energy usage. Investigates the association of information preference variable with academic and personal…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hewett, R.
1997-12-31
This paper describes the strategy and computer processing system that NREL, the Virginia Department of Mines, Minerals and Energy (DMME) and the state energy office, are developing for computing solar attractiveness scores for state agencies and the individual facilities or buildings within each agency. In the case of an agency, solar attractiveness is a measure of that agency`s having a significant number of facilities for which solar has the potential to be promising. In the case of a facility, solar attractiveness is a measure of its potential for being good, economically viable candidate for a solar waste heating system. Virginiamore » State agencies are charged with reducing fossil energy and electricity use and expense. DMME is responsible for working with them to achieve the goals and for managing the state`s energy consumption and cost monitoring program. This is done using the Fast Accounting System for Energy Reporting (FASER) computerized energy accounting and tracking system and database. Agencies report energy use and expenses (by individual facility and energy type) to DMME quarterly. DMME is also responsible for providing technical and other assistance services to agencies and facilities interested in investigating use of solar. Since Virginia has approximately 80 agencies operating over 8,000 energy-consuming facilities and since DMME`s resources are limited, it is interested in being able to determine: (1) on which agencies to focus; (2) specific facilities on which to focus within each high-priority agency; and (3) irrespective of agency, which facilities are the most promising potential candidates for solar. The computer processing system described in this paper computes numerical solar attractiveness scores for the state`s agencies and the individual facilities using the energy use and cost data in the FASER system database and the state`s and NREL`s experience in implementing, testing and evaluating solar water heating systems in commercial and government facilities.« less
Miroshnichenko, Iu V; Umarov, S Z
2012-12-01
One of the ways of increase of effectiveness and safety of patients medication supplement is the use of automated systems of distribution, through which substantially increases the efficiency and safety of patients' medication supplement, achieves significant economy of material and financial resources for medication assistance and possibility of systematical improvement of its accessibility and quality.
Computer Aided Process Planning of Machined Metal Parts
1984-09-01
the manufac- turer to accentuate the positive to assist marketing . Machine usage costs and facility loadings are frequently critical. For example...Variant systems currently on the market include Multiplan (TM of OIR, Inc.), CY-Miplan (TM of Computervision), PICAPP (TM of PICAPP, Inc.) and CSD...Multiproduct, Multistage Manufacturing Systems, Journal of Engineering for Industry, ASME, August 1977. Hitomi, K. and I. Ham, Product Mix and Machine Loading
Impact of Antimicrobial Stewardship on Physician Practice in a Geriatric Facility
Kassett, Nina; Sham, Rosalind; Aleong, Rosanne; Yang, Daisy; Kirzner, Michael; Craft, Aidlee
2016-01-01
Background There is a paucity of literature describing the implementation of antimicrobial stewardship programs (ASPs) in long-term care (LTC) facilities. The current study evaluated the impact of an ASP that was implemented across a geriatric facility, which included an inpatient specialty hospital and an LTC facility. The program included prospective audits with feedback, multidisciplinary education, information technology interventions, and guideline development. Objective To investigate the impact of the ASP on physicians’ prescribing practices in this geriatric facility. Methods Utilization data for antibiotics commonly used to treat urinary tract infections were retrieved for the period September 1, 2011, to August 31, 2013. The study examined whether there were significant changes in overall antibiotic use, ciprofloxacin use, and physician prescribing behaviour after program implementation in September 2012. Results There was no significant change in the total number of antibiotic prescriptions for urinary tract infections in the hospital or the LTC facility after ASP implementation. Significant reductions were seen in the average days of therapy initially prescribed and the actual days of therapy after ASP implementation in the LTC facility but not the hospital. Across both facilities, significant reductions were seen in the number of ciprofloxacin prescriptions. Conclusions The current study showed that an ASP can affect physicians’ antibiotic prescribing behaviour and antibiotic usage in an LTC environment. PMID:28123192
DOE Office of Scientific and Technical Information (OSTI.GOV)
LaClair, Tim; Gao, Zhiming; Fu, Joshua
Quantifying the fuel savings and emissions reductions that can be achieved from truck fuel efficiency technologies for a fleet's specific usage allows the fleet to select a combination of technologies that will yield the greatest operational efficiency and profitability. An accurate characterization of usage for the fleet is critical for such an evaluation; however, short-term measured drive cycle data do not generally reflect overall usage very effectively. This study presents a detailed analysis of vehicle usage in a commercial vehicle fleet and demonstrates the development of a short-duration synthetic drive cycle with measured drive cycle data collected over an extendedmore » period of time. The approach matched statistical measures of the vehicle speed with acceleration history and integrated measured grade data to develop a compressed drive cycle that accurately represents total usage. Drive cycle measurements obtained during a full year from six tractor trailers in normal operations in a less-than-truckload carrier were analyzed to develop a synthetic drive cycle. The vehicle mass was also estimated to account for the variation of loads that the fleet experienced. These drive cycle and mass data were analyzed with a tractive energy analysis to quantify the benefits in terms of fuel efficiency and reduced carbon dioxide emissions that can be achieved on Class 8 tractor trailers by using advanced efficiency technologies, either individually or in combination. Although differences exist between Class 8 tractor trailer fleets, this study provides valuable insight into the energy and emissions reduction potential that various technologies can bring in this important trucking application. Finally, the methodology employed for generating the synthetic drive cycle serves as a rigorous approach to develop an accurate usage characterization that can be used to effectively compress large quantities of drive cycle data.« less
LaClair, Tim; Gao, Zhiming; Fu, Joshua; ...
2014-12-01
Quantifying the fuel savings and emissions reductions that can be achieved from truck fuel efficiency technologies for a fleet's specific usage allows the fleet to select a combination of technologies that will yield the greatest operational efficiency and profitability. An accurate characterization of usage for the fleet is critical for such an evaluation; however, short-term measured drive cycle data do not generally reflect overall usage very effectively. This study presents a detailed analysis of vehicle usage in a commercial vehicle fleet and demonstrates the development of a short-duration synthetic drive cycle with measured drive cycle data collected over an extendedmore » period of time. The approach matched statistical measures of the vehicle speed with acceleration history and integrated measured grade data to develop a compressed drive cycle that accurately represents total usage. Drive cycle measurements obtained during a full year from six tractor trailers in normal operations in a less-than-truckload carrier were analyzed to develop a synthetic drive cycle. The vehicle mass was also estimated to account for the variation of loads that the fleet experienced. These drive cycle and mass data were analyzed with a tractive energy analysis to quantify the benefits in terms of fuel efficiency and reduced carbon dioxide emissions that can be achieved on Class 8 tractor trailers by using advanced efficiency technologies, either individually or in combination. Although differences exist between Class 8 tractor trailer fleets, this study provides valuable insight into the energy and emissions reduction potential that various technologies can bring in this important trucking application. Finally, the methodology employed for generating the synthetic drive cycle serves as a rigorous approach to develop an accurate usage characterization that can be used to effectively compress large quantities of drive cycle data.« less
NASA Astrophysics Data System (ADS)
Laanearu, J.; Borodinecs, A.; Rimeika, M.; Palm, B.
2017-10-01
The thermal-energy potential of urban water sources is largely unused to accomplish the up-to-date requirements of the buildings energy demands in the cities of Baltic Sea Region. A reason is that the natural and excess-heat water sources have a low temperature and heat that should be upgraded before usage. The demand for space cooling should increase in near future with thermal insulation of buildings. There are a number of options to recover heat also from wastewater. It is proposed that a network of heat extraction and insertion including the thermal-energy recovery schemes has potential to be broadly implemented in the region with seasonally alternating temperature. The mapping of local conditions is essential in finding the suitable regions (hot spots) for future application of a heat recovery schemes by combining information about demands with information about available sources. The low-temperature water in the urban environment is viewed as a potential thermal-energy source. To recover thermal energy efficiently, it is also essential to ensure that it is used locally, and adverse effects on environment and industrial processes are avoided. Some characteristics reflecting the energy usage are discussed in respect of possible improvements of energy efficiency.
Issues in International Energy Consumption Analysis: Electricity Usage in India’s Housing Sector
2014-01-01
India offers a unique set of features for studying electricity use in the context of a developing country. First, it has a rapidly developing economy with high yearly growth rates in gross domestic product (GDP). Second, it has the second -largest population in the world and is likely to have the largest population in the future. Third, its electric system is maturing—with known difficulties (outages, shortages, issues with reliability and quality) that are characteristic of a developing country. This article focuses on electricity use in the residential sector of India and discusses key trends and provides an overview of available usage estimates from various sources. Indian households are an interesting environment where many of India’s unique features interact. The recent economic gains correlate with rising incomes and possible changes in living standards, which could affect electricity or other energy use within households. Additionally, the maturing electric system and large population in India both offer opportunities to study a range of interactions between electrification and electricity usage in a developing country.
10 CFR 4.127 - Existing facilities.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 1 2010-01-01 2010-01-01 false Existing facilities. 4.127 Section 4.127 Energy NUCLEAR... 1973, as Amended Discriminatory Practices § 4.127 Existing facilities. (a) Accessibility. A recipient... make each of its existing facilities or every part of an existing facility accessible to and usable by...
10 CFR 1042.410 - Comparable facilities.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 4 2010-01-01 2010-01-01 false Comparable facilities. 1042.410 Section 1042.410 Energy... Activities Prohibited § 1042.410 Comparable facilities. A recipient may provide separate toilet, locker room, and shower facilities on the basis of sex, but such facilities provided for students of one sex shall...
10 CFR 1040.72 - Existing facilities.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 4 2010-01-01 2010-01-01 false Existing facilities. 1040.72 Section 1040.72 Energy... § 1040.72 Existing facilities. (a) Accessibility. A recipient shall operate any program or activity to... facilities or every part of a facility accessible to and useable by handicapped persons. (b) Methods. A...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lekov, Alex; Thompson, Lisa; McKane, Aimee
This report summarizes the Lawrence Berkeley National Laboratory?s research to date in characterizing energy efficiency and automated demand response opportunities for wastewater treatment facilities in California. The report describes the characteristics of wastewater treatment facilities, the nature of the wastewater stream, energy use and demand, as well as details of the wastewater treatment process. It also discusses control systems and energy efficiency and automated demand response opportunities. In addition, several energy efficiency and load management case studies are provided for wastewater treatment facilities.This study shows that wastewater treatment facilities can be excellent candidates for open automated demand response and thatmore » facilities which have implemented energy efficiency measures and have centralized control systems are well-suited to shift or shed electrical loads in response to financial incentives, utility bill savings, and/or opportunities to enhance reliability of service. Control technologies installed for energy efficiency and load management purposes can often be adapted for automated demand response at little additional cost. These improved controls may prepare facilities to be more receptive to open automated demand response due to both increased confidence in the opportunities for controlling energy cost/use and access to the real-time data.« less
48 CFR 926.7103 - Requirements.
Code of Federal Regulations, 2010 CFR
2010-10-01
... preference in hiring to an eligible employee of Department of Energy Defense Nuclear Facilities. This right... and subcontractors employed at Department of Energy Defense Nuclear Facilities, to the extent... implementation of Section 3161 at the Department of Energy Defense Nuclear Facility and local counsel, should...
48 CFR 926.7103 - Requirements.
Code of Federal Regulations, 2014 CFR
2014-10-01
... preference in hiring to an eligible employee of Department of Energy Defense Nuclear Facilities. This right... and subcontractors employed at Department of Energy Defense Nuclear Facilities, to the extent... implementation of Section 3161 at the Department of Energy Defense Nuclear Facility and local counsel, should...
48 CFR 926.7103 - Requirements.
Code of Federal Regulations, 2013 CFR
2013-10-01
... preference in hiring to an eligible employee of Department of Energy Defense Nuclear Facilities. This right... and subcontractors employed at Department of Energy Defense Nuclear Facilities, to the extent... implementation of Section 3161 at the Department of Energy Defense Nuclear Facility and local counsel, should...
48 CFR 926.7103 - Requirements.
Code of Federal Regulations, 2012 CFR
2012-10-01
... preference in hiring to an eligible employee of Department of Energy Defense Nuclear Facilities. This right... and subcontractors employed at Department of Energy Defense Nuclear Facilities, to the extent... implementation of Section 3161 at the Department of Energy Defense Nuclear Facility and local counsel, should...
48 CFR 926.7103 - Requirements.
Code of Federal Regulations, 2011 CFR
2011-10-01
... preference in hiring to an eligible employee of Department of Energy Defense Nuclear Facilities. This right... and subcontractors employed at Department of Energy Defense Nuclear Facilities, to the extent... implementation of Section 3161 at the Department of Energy Defense Nuclear Facility and local counsel, should...
48 CFR 952.204-73 - Facility clearance.
Code of Federal Regulations, 2014 CFR
2014-10-01
....204-73 Section 952.204-73 Federal Acquisition Regulations System DEPARTMENT OF ENERGY CLAUSES AND... granted by the Secretary of Energy. In addition, a Facility Clearance and foreign ownership, control and... Department of Energy Facility Clearance generally need not resubmit the following foreign ownership...
48 CFR 952.204-73 - Facility clearance.
Code of Federal Regulations, 2011 CFR
2011-10-01
....204-73 Section 952.204-73 Federal Acquisition Regulations System DEPARTMENT OF ENERGY CLAUSES AND... granted by the Secretary of Energy. In addition, a Facility Clearance and foreign ownership, control and... Department of Energy Facility Clearance generally need not resubmit the following foreign ownership...
48 CFR 952.204-73 - Facility clearance.
Code of Federal Regulations, 2012 CFR
2012-10-01
....204-73 Section 952.204-73 Federal Acquisition Regulations System DEPARTMENT OF ENERGY CLAUSES AND... granted by the Secretary of Energy. In addition, a Facility Clearance and foreign ownership, control and... Department of Energy Facility Clearance generally need not resubmit the following foreign ownership...
48 CFR 952.204-73 - Facility clearance.
Code of Federal Regulations, 2013 CFR
2013-10-01
....204-73 Section 952.204-73 Federal Acquisition Regulations System DEPARTMENT OF ENERGY CLAUSES AND... granted by the Secretary of Energy. In addition, a Facility Clearance and foreign ownership, control and... Department of Energy Facility Clearance generally need not resubmit the following foreign ownership...
48 CFR 952.204-73 - Facility clearance.
Code of Federal Regulations, 2010 CFR
2010-10-01
....204-73 Section 952.204-73 Federal Acquisition Regulations System DEPARTMENT OF ENERGY CLAUSES AND... granted by the Secretary of Energy. In addition, a Facility Clearance and foreign ownership, control and... Department of Energy Facility Clearance generally need not resubmit the following foreign ownership...
Cars and Kinetic Energy--Some Simple Physics with Real-World Relevance
ERIC Educational Resources Information Center
Parthasarathy, Raghuveer
2012-01-01
Understanding energy usage is crucial to understanding modern civilization, as well as many of the challenges it faces. Energy-related issues also offer real-world examples of important physical concepts, and as such have been the focus of several articles in "The Physics Teacher" in the past few decades (e.g., Refs. 1-5, noted further below).…
NASA Astrophysics Data System (ADS)
Murphy, Thomas W.
2011-11-01
This article explores a variety of ways to measure, adjust, and augment home energy usage. Particular examples of using electricity and gas utility meters, power/energy meters for individual devices, whole-home energy monitoring, infrared cameras, and thermal measurements are discussed—leading to a factor-of-four reduction in home energy use in the case discussed. The net efficiency performance of a stand-alone photovoltaic system is also presented. Ideas for reducing one's energy/carbon footprint both within the home and in the larger community are quantitatively evaluated.
Energy Efficiency in Water and Wastewater Facilities
Learn how local governments have achieved sustained energy improvements at their water and wastewater facilities through equipment upgrades, operational modifications, and modifications to facility buildings.
NASA Astrophysics Data System (ADS)
Baiya, Evanson G.
New energy technologies that provide real-time visibility of the electricity grid's performance, along with the ability to address unusual events in the grid and allow consumers to manage their energy use, are being developed in the United States. Primary drivers for the new technologies include the growing energy demand, tightening environmental regulations, aging electricity infrastructure, and rising consumer demand to become more involved in managing individual energy usage. In the literature and in practice, it is unclear if, and to what extent, residential consumers will adopt smart grid technologies. The purpose of this quantitative study was to examine the relationships between demographic characteristics, perceptions, and the likelihood of adopting smart grid technologies among residential energy consumers. The results of a 31-item survey were analyzed for differences within the Idaho consumers and compared against national consumers. Analysis of variance was used to examine possible differences between the dependent variable of likeliness to adopt smart grid technologies and the independent variables of age, gender, residential ownership, and residential location. No differences were found among Idaho consumers in their likeliness to adopt smart grid technologies. An independent sample t-test was used to examine possible differences between the two groups of Idaho consumers and national consumers in their level of interest in receiving detailed feedback information on energy usage, the added convenience of the smart grid, renewable energy, the willingness to pay for infrastructure costs, and the likeliness to adopt smart grid technologies. The level of interest in receiving detailed feedback information on energy usage was significantly different between the two groups (t = 3.11, p = .0023), while the other variables were similar. The study contributes to technology adoption research regarding specific consumer perceptions and provides a framework that estimates the likeliness of adopting smart grid technologies by residential consumers. The study findings could assist public utility managers and technology adoption researchers as they develop strategies to enable wide-scale adoption of smart grid technologies as a solution to the energy problem. Future research should be conducted among commercial and industrial energy consumers to further validate the findings and conclusions of this research.
From Tragedy to Triumph - Rebuilding Green Homes after Disaster (Fact Sheet)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
2009-04-01
Energy Efficiency/Renewable Energy Fact Sheets, No. 1. Series to include practical, useful info to help people change their behavior around energy usage and "greenness". Greensburg is hanging its future on sustainable development; these fact sheet sheets should help citizens understand what they can do to be a part of that focus. Fact Sheets cover: saving energy and water, using renewable energy (particular interest in small wind), driving "green", general sustainability, living green.
Energy Sourcebook for Educational Facilities.
ERIC Educational Resources Information Center
Council of Educational Facility Planners, Columbus, OH.
The Council of Educational Facility Planners, International (CEFP/I) has assembled an authoritative and comprehensive sourcebook for the design and management of energy efficient educational facilities. Information that bridges the gap between scientific energy theory/research/technology and the needs of the educational community is published in…
Smart energy management system
NASA Astrophysics Data System (ADS)
Desai, Aniruddha; Singh, Jugdutt
2010-04-01
Peak and average energy usage in domestic and industrial environments is growing rapidly and absence of detailed energy consumption metrics is making systematic reduction of energy usage very difficult. Smart energy management system aims at providing a cost-effective solution for managing soaring energy consumption and its impact on green house gas emissions and climate change. The solution is based on seamless integration of existing wired and wireless communication technologies combined with smart context-aware software which offers a complete solution for automation of energy measurement and device control. The persuasive software presents users with easy-to-assimilate visual cues identifying problem areas and time periods and encourages a behavioural change to conserve energy. The system allows analysis of real-time/statistical consumption data with the ability to drill down into detailed analysis of power consumption, CO2 emissions and cost. The system generates intelligent projections and suggests potential methods (e.g. reducing standby, tuning heating/cooling temperature, etc.) of reducing energy consumption. The user interface is accessible using web enabled devices such as PDAs, PCs, etc. or using SMS, email, and instant messaging. Successful real-world trial of the system has demonstrated the potential to save 20 to 30% energy consumption on an average. Low cost of deployment and the ability to easily manage consumption from various web enabled devices offers gives this system a high penetration and impact capability offering a sustainable solution to act on climate change today.
Implementing iRound: A Computer-Based Auditing Tool.
Brady, Darcie
Many hospitals use rounding or auditing as a tool to help identify gaps and needs in quality and process performance. Some hospitals are also using rounding to help improve patient experience. It is known that purposeful rounding helps improve Hospital Consumer Assessment of Healthcare Providers and Systems scores by helping manage patient expectations, provide service recovery, and recognize quality caregivers. Rounding works when a standard method is used across the facility, where data are comparable and trustworthy. This facility had a pen-and-paper process in place that made data reporting difficult, created a silo culture between departments, and most audits and rounds were completed differently on each unit. It was recognized that this facility needed to standardize the rounding and auditing process. The tool created by the Advisory Board called iRound was chosen as the tool this facility would use for patient experience rounds as well as process and quality rounding. The success of the iRound tool in this facility depended on several factors that started many months before implementation to current everyday usage.
10 CFR 5.410 - Comparable facilities.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 1 2010-01-01 2010-01-01 false Comparable facilities. 5.410 Section 5.410 Energy NUCLEAR... Prohibited § 5.410 Comparable facilities. A recipient may provide separate toilet, locker room, and shower facilities on the basis of sex, but such facilities provided for students of one sex shall be comparable to...
Research Support Facility (RSF): Leadership in Building Performance (Brochure)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
This brochure/poster provides information on the features of the Research Support Facility including a detailed illustration of the facility with call outs of energy efficiency and renewable energy technologies. Imagine an office building so energy efficient that its occupants consume only the amount of energy generated by renewable power on the building site. The building, the Research Support Facility (RSF) occupied by the U.S. Department of Energy's National Renewable Energy Laboratory (NREL) employees, uses 50% less energy than if it were built to current commercial code and achieves the U.S. Green Building Council's Leadership in Energy and Environmental Design (LEED{reg_sign})more » Platinum rating. With 19% of the primary energy in the U.S. consumed by commercial buildings, the RSF is changing the way commercial office buildings are designed and built.« less
Energy Systems Integration Facility Insight Center | Energy Systems
simulation data. Photo of researchers studying data on a 3-D power system profile depicting the interaction of renewable energy resources on the grid. Capabilities The Insight Center offers the following Integration Facility Insight Center Located adjacent to the Energy System Integration Facility's High
10 CFR 205.378 - Disconnection of temporary facilities.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 3 2010-01-01 2010-01-01 false Disconnection of temporary facilities. 205.378 Section 205.378 Energy DEPARTMENT OF ENERGY OIL ADMINISTRATIVE PROCEDURES AND SANCTIONS Electric Power System... Electric Facilities and the Transfer of Electricity to Alleviate An Emergency Shortage of Electric Power...
10 CFR 850.27 - Hygiene facilities and practices.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 4 2010-01-01 2010-01-01 false Hygiene facilities and practices. 850.27 Section 850.27 Energy DEPARTMENT OF ENERGY CHRONIC BERYLLIUM DISEASE PREVENTION PROGRAM Specific Program Requirements § 850.27 Hygiene facilities and practices. (a) General. The responsible employer must assure that in...
HEP Outreach, Inreach, and Web 2.0
NASA Astrophysics Data System (ADS)
Goldfarb, Steven
2011-12-01
I report on current usage of multimedia and social networking "Web 2.0" tools for Education and Outreach in high-energy physics, and discuss their potential for internal communication within large worldwide collaborations, such as those of the LHC. Following a brief description of the history of Web 2.0 development, I present a survey of the most popular sites and describe their usage in HEP to disseminate information to students and the general public. I then discuss the potential of certain specific tools, such as document and multimedia sharing sites, for boosting the speed and effectiveness of information exchange within the collaborations. I conclude with a brief discussion of the successes and failures of these tools, and make suggestions for improved usage in the future.
Kim, Choong-Ki; Toft, Jodie E; Papenfus, Michael; Verutes, Gregory; Guerry, Anne D; Ruckelshaus, Marry H; Arkema, Katie K; Guannel, Gregory; Wood, Spencer A; Bernhardt, Joanna R; Tallis, Heather; Plummer, Mark L; Halpern, Benjamin S; Pinsky, Malin L; Beck, Michael W; Chan, Francis; Chan, Kai M A; Levin, Phil S; Polasky, Stephen
2012-01-01
Many hope that ocean waves will be a source for clean, safe, reliable and affordable energy, yet wave energy conversion facilities may affect marine ecosystems through a variety of mechanisms, including competition with other human uses. We developed a decision-support tool to assist siting wave energy facilities, which allows the user to balance the need for profitability of the facilities with the need to minimize conflicts with other ocean uses. Our wave energy model quantifies harvestable wave energy and evaluates the net present value (NPV) of a wave energy facility based on a capital investment analysis. The model has a flexible framework and can be easily applied to wave energy projects at local, regional, and global scales. We applied the model and compatibility analysis on the west coast of Vancouver Island, British Columbia, Canada to provide information for ongoing marine spatial planning, including potential wave energy projects. In particular, we conducted a spatial overlap analysis with a variety of existing uses and ecological characteristics, and a quantitative compatibility analysis with commercial fisheries data. We found that wave power and harvestable wave energy gradually increase offshore as wave conditions intensify. However, areas with high economic potential for wave energy facilities were closer to cable landing points because of the cost of bringing energy ashore and thus in nearshore areas that support a number of different human uses. We show that the maximum combined economic benefit from wave energy and other uses is likely to be realized if wave energy facilities are sited in areas that maximize wave energy NPV and minimize conflict with existing ocean uses. Our tools will help decision-makers explore alternative locations for wave energy facilities by mapping expected wave energy NPV and helping to identify sites that provide maximal returns yet avoid spatial competition with existing ocean uses.
Kim, Choong-Ki; Toft, Jodie E.; Papenfus, Michael; Verutes, Gregory; Guerry, Anne D.; Ruckelshaus, Marry H.; Arkema, Katie K.; Guannel, Gregory; Wood, Spencer A.; Bernhardt, Joanna R.; Tallis, Heather; Plummer, Mark L.; Halpern, Benjamin S.; Pinsky, Malin L.; Beck, Michael W.; Chan, Francis; Chan, Kai M. A.; Levin, Phil S.; Polasky, Stephen
2012-01-01
Many hope that ocean waves will be a source for clean, safe, reliable and affordable energy, yet wave energy conversion facilities may affect marine ecosystems through a variety of mechanisms, including competition with other human uses. We developed a decision-support tool to assist siting wave energy facilities, which allows the user to balance the need for profitability of the facilities with the need to minimize conflicts with other ocean uses. Our wave energy model quantifies harvestable wave energy and evaluates the net present value (NPV) of a wave energy facility based on a capital investment analysis. The model has a flexible framework and can be easily applied to wave energy projects at local, regional, and global scales. We applied the model and compatibility analysis on the west coast of Vancouver Island, British Columbia, Canada to provide information for ongoing marine spatial planning, including potential wave energy projects. In particular, we conducted a spatial overlap analysis with a variety of existing uses and ecological characteristics, and a quantitative compatibility analysis with commercial fisheries data. We found that wave power and harvestable wave energy gradually increase offshore as wave conditions intensify. However, areas with high economic potential for wave energy facilities were closer to cable landing points because of the cost of bringing energy ashore and thus in nearshore areas that support a number of different human uses. We show that the maximum combined economic benefit from wave energy and other uses is likely to be realized if wave energy facilities are sited in areas that maximize wave energy NPV and minimize conflict with existing ocean uses. Our tools will help decision-makers explore alternative locations for wave energy facilities by mapping expected wave energy NPV and helping to identify sites that provide maximal returns yet avoid spatial competition with existing ocean uses. PMID:23144824
Validating Innovative Renewable Energy Technologies: ESTCP Demonstrations at Two DoD Facilities
2011-11-01
4. TITLE AND SUBTITLE Validating Innovative Renewable Energy Technologies: ESTCP Demonstrations at Two DoD Facilities 5a. CONTRACT NUMBER 5b...goals of 25% of energy consumed required to be from renewable energy by 2025, the DoD has set aggressive, yet achievable targets. With its array of land...holdings facilities, and environments, the potential for renewable energy generation on DoD lands is great. Reaching these goals will require
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xu, Tengfang; Flapper, Joris; Ke, Jing
The overall goal of the project is to develop a computer-based benchmarking and energy and water savings tool (BEST-Dairy) for use in the California dairy industry - including four dairy processes - cheese, fluid milk, butter, and milk powder. BEST-Dairy tool developed in this project provides three options for the user to benchmark each of the dairy product included in the tool, with each option differentiated based on specific detail level of process or plant, i.e., 1) plant level; 2) process-group level, and 3) process-step level. For each detail level, the tool accounts for differences in production and other variablesmore » affecting energy use in dairy processes. The dairy products include cheese, fluid milk, butter, milk powder, etc. The BEST-Dairy tool can be applied to a wide range of dairy facilities to provide energy and water savings estimates, which are based upon the comparisons with the best available reference cases that were established through reviewing information from international and national samples. We have performed and completed alpha- and beta-testing (field testing) of the BEST-Dairy tool, through which feedback from voluntary users in the U.S. dairy industry was gathered to validate and improve the tool's functionality. BEST-Dairy v1.2 was formally published in May 2011, and has been made available for free downloads from the internet (i.e., http://best-dairy.lbl.gov). A user's manual has been developed and published as the companion documentation for use with the BEST-Dairy tool. In addition, we also carried out technology transfer activities by engaging the dairy industry in the process of tool development and testing, including field testing, technical presentations, and technical assistance throughout the project. To date, users from more than ten countries in addition to those in the U.S. have downloaded the BEST-Dairy from the LBNL website. It is expected that the use of BEST-Dairy tool will advance understanding of energy and water usage in individual dairy plants, augment benchmarking activities in the market places, and facilitate implementation of efficiency measures and strategies to save energy and water usage in the dairy industry. Industrial adoption of this emerging tool and technology in the market is expected to benefit dairy plants, which are important customers of California utilities. Further demonstration of this benchmarking tool is recommended, for facilitating its commercialization and expansion in functions of the tool. Wider use of this BEST-Dairy tool and its continuous expansion (in functionality) will help to reduce the actual consumption of energy and water in the dairy industry sector. The outcomes comply very well with the goals set by the AB 1250 for PIER program.« less
Meeting the Energy Challenges of the 1990s. Experts Define the Key Policy Issues.
1992-03-01
Forecast of Low Emission Fuel Usage-Liquid 79 Fuels Figure 2.10: Forecast of Low Emission Fuel Usage- 81 Gaseous Fuels Figure 2.11: Global Warming From...environmental problems caused by acid rain, smog, and global warming , he said. According to Mr. Lovins, utilities as well as their customers benefit from...made in relation to these effects. The panel- ists addressed the links between global warming and the fossil fuels that now produce nearly 90 percent
CO2 laser arthroscopy-through the arthroscope
NASA Astrophysics Data System (ADS)
Garrick, James G.
1990-06-01
Orthopedists have been among the last of the specialists to utilize lasers in surgery. Even today, laser usage in orthopedics is almost exclusively limited to arthroscopy procedures. Although other types of lasers have been approved for use in orthopedics, nearly all laser-assisted arthroscopic procedures have involved the carbon dioxide laser in the knee. These techniques involve skills and problems not previously encountered. In an attempt to simplify the usage and circumvent some of the problems, we describe a means of laser energy delivery through the arthroscope.
10 CFR 1016.39 - Termination, suspension, or revocation of security facility approval.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 4 2011-01-01 2011-01-01 false Termination, suspension, or revocation of security facility approval. 1016.39 Section 1016.39 Energy DEPARTMENT OF ENERGY (GENERAL PROVISIONS) SAFEGUARDING OF RESTRICTED DATA Control of Information § 1016.39 Termination, suspension, or revocation of security facility...
10 CFR 1016.39 - Termination, suspension, or revocation of security facility approval.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 4 2010-01-01 2010-01-01 false Termination, suspension, or revocation of security facility approval. 1016.39 Section 1016.39 Energy DEPARTMENT OF ENERGY (GENERAL PROVISIONS) SAFEGUARDING OF RESTRICTED DATA Control of Information § 1016.39 Termination, suspension, or revocation of security facility...
10 CFR 1016.11 - Cancellation of requests for security facility approval.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 4 2011-01-01 2011-01-01 false Cancellation of requests for security facility approval. 1016.11 Section 1016.11 Energy DEPARTMENT OF ENERGY (GENERAL PROVISIONS) SAFEGUARDING OF RESTRICTED DATA Physical Security § 1016.11 Cancellation of requests for security facility approval. When a...
10 CFR 1016.11 - Cancellation of requests for security facility approval.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 4 2010-01-01 2010-01-01 false Cancellation of requests for security facility approval. 1016.11 Section 1016.11 Energy DEPARTMENT OF ENERGY (GENERAL PROVISIONS) SAFEGUARDING OF RESTRICTED DATA Physical Security § 1016.11 Cancellation of requests for security facility approval. When a...
10 CFR 1016.10 - Grant, denial, or suspension of security facility approval.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 4 2010-01-01 2010-01-01 false Grant, denial, or suspension of security facility approval. 1016.10 Section 1016.10 Energy DEPARTMENT OF ENERGY (GENERAL PROVISIONS) SAFEGUARDING OF RESTRICTED DATA Physical Security § 1016.10 Grant, denial, or suspension of security facility approval...
10 CFR 1016.10 - Grant, denial, or suspension of security facility approval.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 4 2011-01-01 2011-01-01 false Grant, denial, or suspension of security facility approval. 1016.10 Section 1016.10 Energy DEPARTMENT OF ENERGY (GENERAL PROVISIONS) SAFEGUARDING OF RESTRICTED DATA Physical Security § 1016.10 Grant, denial, or suspension of security facility approval...
Supervisory Control and Data Acquisition System | Energy Systems
Integration Facility | NREL Supervisory Control and Data Acquisition System Supervisory Control supervisory control and data acquisition (SCADA) system monitors and controls safety systems and gathers real Energy Systems Integration Facility control room. The Energy Systems Integration Facility's SCADA system
10 CFR 1016.10 - Grant, denial, or suspension of security facility approval.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 4 2012-01-01 2012-01-01 false Grant, denial, or suspension of security facility approval. 1016.10 Section 1016.10 Energy DEPARTMENT OF ENERGY (GENERAL PROVISIONS) SAFEGUARDING OF RESTRICTED DATA Physical Security § 1016.10 Grant, denial, or suspension of security facility approval...
10 CFR 50.78 - Facility information and verification.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 1 2011-01-01 2011-01-01 false Facility information and verification. 50.78 Section 50.78 Energy NUCLEAR REGULATORY COMMISSION DOMESTIC LICENSING OF PRODUCTION AND UTILIZATION FACILITIES Us/iaea... International Atomic Energy Agency (IAEA) and take other action as necessary to implement the US/IAEA Safeguards...
10 CFR 50.78 - Facility information and verification.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 1 2010-01-01 2010-01-01 false Facility information and verification. 50.78 Section 50.78 Energy NUCLEAR REGULATORY COMMISSION DOMESTIC LICENSING OF PRODUCTION AND UTILIZATION FACILITIES Us/iaea... International Atomic Energy Agency (IAEA) and take other action as necessary to implement the US/IAEA Safeguards...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-24
... support safe operation of Autoclave 2 of the facility have been constructed in accordance with the... Inspection Reports Regarding Louisiana Energy Services, National Enrichment Facility, Eunice, New Mexico... Louisiana Energy Services (LES), LLC, National Enrichment Facility in Eunice, New Mexico, and has authorized...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Laurie, Carol
2017-02-01
This book takes readers inside the places where daily discoveries shape the next generation of wind power systems. Energy Department laboratory facilities span the United States and offer wind research capabilities to meet industry needs. The facilities described in this book make it possible for industry players to increase reliability, improve efficiency, and reduce the cost of wind energy -- one discovery at a time. Whether you require blade testing or resource characterization, grid integration or high-performance computing, Department of Energy laboratory facilities offer a variety of capabilities to meet your wind research needs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Office of Energy Efficiency and Renewable Energy
This book takes readers inside the places where daily discoveries shape the next generation of wind power systems. Energy Department laboratory facilities span the United States and offer wind research capabilities to meet industry needs. The facilities described in this book make it possible for industry players to increase reliability, improve efficiency, and reduce the cost of wind energy -- one discovery at a time. Whether you require blade testing or resource characterization, grid integration or high-performance computing, Department of Energy laboratory facilities offer a variety of capabilities to meet your wind research needs.
Stang, Shannon; Wang, Haiying; Gardner, Kevin H; Mo, Weiwei
2018-07-15
As drinking water supply systems plan for sustainable management practices, impacts from future water quality and climate changes are a major concern. This study aims to understand the intraannual changes of energy consumption for water treatment, investigate the relative importance of water quality and climate indicators on energy consumption for water treatment, and predict the effects of climate change on the embodied energy of treated, potable water at two municipal drinking water systems located in the northeast and southeast US. To achieve this goal, a life cycle assessment was first performed to quantify the monthly energy consumption in the two drinking water systems. Regression and relative importance analyses were then performed between climate indicators, raw water quality indicators, and chemical and energy usages in the treatment processes to determine their correlations. These relationships were then used to project changes in embodied energy associated with the plants' processes, and the results were compared between the two regions. The projections of the southeastern US water plant were for an increase in energy demand resulted from an increase of treatment chemical usages. The northeastern US plant was projected to decrease its energy demand due to a reduced demand for heating the plant's infrastructure. The findings indicate that geographic location and treatment process may determine the way climate change affects drinking water systems. Copyright © 2018 Elsevier Ltd. All rights reserved.
Code of Federal Regulations, 2011 CFR
2011-07-01
... facilities on my limited lease or any facilities on my project easement proposed under my GAP? 285.651 Section 285.651 Mineral Resources BUREAU OF OCEAN ENERGY MANAGEMENT, REGULATION, AND ENFORCEMENT, DEPARTMENT OF THE INTERIOR OFFSHORE RENEWABLE ENERGY ALTERNATE USES OF EXISTING FACILITIES ON THE OUTER...
Code of Federal Regulations, 2014 CFR
2014-01-01
... ENERGY ENERGY CONSERVATION RENEWABLE ENERGY PRODUCTION INCENTIVES § 451.2 Definitions. As used in this... used at a qualified renewable energy facility to generate electricity. Date of first use means, at the... excludes electric energy used within the renewable energy facility to power equipment such as pumps, motors...
Code of Federal Regulations, 2012 CFR
2012-01-01
... ENERGY ENERGY CONSERVATION RENEWABLE ENERGY PRODUCTION INCENTIVES § 451.2 Definitions. As used in this... used at a qualified renewable energy facility to generate electricity. Date of first use means, at the... excludes electric energy used within the renewable energy facility to power equipment such as pumps, motors...
Code of Federal Regulations, 2013 CFR
2013-01-01
... ENERGY ENERGY CONSERVATION RENEWABLE ENERGY PRODUCTION INCENTIVES § 451.2 Definitions. As used in this... used at a qualified renewable energy facility to generate electricity. Date of first use means, at the... excludes electric energy used within the renewable energy facility to power equipment such as pumps, motors...
Development of an Enhanced Payback Function for the Superior Energy Performance Program
DOE Office of Scientific and Technical Information (OSTI.GOV)
Therkelsen, Peter; Rao, Prakash; McKane, Aimee
2015-08-03
The U.S. DOE Superior Energy Performance (SEP) program provides recognition to industrial and commercial facilities that achieve certification to the ISO 50001 energy management system standard and third party verification of energy performance improvements. Over 50 industrial facilities are participating and 28 facilities have been certified in the SEP program. These facilities find value in the robust, data driven energy performance improvement result that the SEP program delivers. Previous analysis of SEP certified facility data demonstrated the cost effectiveness of SEP and identified internal staff time to be the largest cost component related to SEP implementation and certification. This papermore » analyzes previously reported and newly collected data of costs and benefits associated with the implementation of an ISO 50001 and SEP certification. By disaggregating “sunk energy management system (EnMS) labor costs”, this analysis results in a more accurate and detailed understanding of the costs and benefits of SEP participation. SEP is shown to significantly improve and sustain energy performance and energy cost savings, resulting in a highly attractive return on investment. To illustrate these results, a payback function has been developed and is presented. On average facilities with annual energy spend greater than $2M can expect to implement SEP with a payback of less than 1.5 years. Finally, this paper also observes and details decreasing facility costs associated with implementing ISO 50001 and certifying to the SEP program, as the program has improved from pilot, to demonstration, to full launch.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
LaClair, Tim J; Gao, Zhiming; Fu, Joshua S.
2014-01-01
Quantifying the fuel savings that can be achieved from different truck fuel efficiency technologies for a fleet s specific usage allows the fleet to select the combination of technologies that will yield the greatest operational efficiency and profitability. This paper presents an analysis of vehicle usage in a commercial vehicle fleet and an assessment of advanced efficiency technologies using an analysis of measured drive cycle data for a class 8 regional commercial shipping fleet. Drive cycle measurements during a period of a full year from six tractor-trailers in normal operations in a less-than-truckload (LTL) carrier were analyzed to develop amore » characteristic drive cycle that is highly representative of the fleet s usage. The vehicle mass was also estimated to account for the variation of loads that the fleet experienced. The drive cycle and mass data were analyzed using a tractive energy analysis to quantify the fuel efficiency and CO2 emissions benefits that can be achieved on class 8 tractor-trailers when using advanced efficiency technologies, either individually or in combination. Although differences exist among class 8 tractor-trailer fleets, this study provides valuable insight into the energy and emissions reduction potential that various technologies can bring in this important trucking application.« less
ERIC Educational Resources Information Center
Tortop, Hasan Said
2012-01-01
Turkey is the one of the countries in the world which has potential of renewable energy resource because of its geographical position. However, being usage of renewable energy resources and applications (RERAs) is low, it shows that awareness and consciousness of RERAs is very low too. Education must play a key role in growing out of an energy…
Study of the Potential Energy Consumption Impacts of Connected and Automated Vehicles
2017-01-01
A new study commissioned by the U.S. Energy Information Administration, finds that the introduction of connected and automated vehicle technologies have the potential to affect vehicle energy consumption, travel, usage, vehicle design and attributes, and personal ownership rates. Rate of technology development, consumer acceptance, and regulatory support and oversight will affect the rate of market penetration of these vehicle technologies.
Analysis of Non-Tactical Vehicle Utilization at Fort Carson Colorado
2012-01-01
regenerative braking energy recovery. The mass of the vehicles monitored in this study was not known. However, some useful information may be... regenerative energy recovery potential for specific duty cycles was also quantified through a cumulative assessment of the number and severity of deceleration...extracted on usage time, distance, vehicle speed and geographic location in order to compare vehicle driving profiles. The regenerative energy recovery
Waste to Energy at SUNY Cobleskill
2011-05-10
Overview on Army Net Zero Concepts • Gasification Intro. • SUNY Cobleskill Center for Environmental Science and Technology. • TURNW2E™ Gasification ...5 GASIFICATION A TECHNOLOGY 2-fer • Waste Reduction • Reduced Logistics for Waste Transportation • Reduced environmental and personnel impact... GASIFICATION Ash ENERGYWaste T ~ 800oC Partial Combustion O/C ~1/3 • Energy Production • Reduced Fuel Usage for transportation • Increased Energy
Code of Federal Regulations, 2013 CFR
2013-01-01
... Test Procedure,” and Chapter 6, “Definitions and Acronyms,” of the EPA's “ENERGY STAR Testing Facility Guidance Manual: Building a Testing Facility and Performing the Solid State Test Method for ENERGY STAR... specified in Chapter 4, “Equipment Setup and Test Procedure,” of the EPA's “ENERGY STAR Testing Facility...
Code of Federal Regulations, 2012 CFR
2012-01-01
... Test Procedure,” and Chapter 6, “Definitions and Acronyms,” of the EPA's “ENERGY STAR Testing Facility Guidance Manual: Building a Testing Facility and Performing the Solid State Test Method for ENERGY STAR... specified in Chapter 4, “Equipment Setup and Test Procedure,” of the EPA's “ENERGY STAR Testing Facility...
Code of Federal Regulations, 2014 CFR
2014-01-01
... Test Procedure,” and Chapter 6, “Definitions and Acronyms,” of the EPA's “ENERGY STAR Testing Facility Guidance Manual: Building a Testing Facility and Performing the Solid State Test Method for ENERGY STAR... specified in Chapter 4, “Equipment Setup and Test Procedure,” of the EPA's “ENERGY STAR Testing Facility...
Code of Federal Regulations, 2011 CFR
2011-01-01
... Test Procedure,” and Chapter 6, “Definitions and Acronyms,” of the EPA's “ENERGY STAR Testing Facility Guidance Manual: Building a Testing Facility and Performing the Solid State Test Method for ENERGY STAR... specified in Chapter 4, “Equipment Setup and Test Procedure,” of the EPA's “ENERGY STAR Testing Facility...
The CERN-EU high-energy Reference Field (CERF) facility: applications and latest developments
NASA Astrophysics Data System (ADS)
Silari, Marco; Pozzi, Fabio
2017-09-01
The CERF facility at CERN provides an almost unique high-energy workplace reference radiation field for the calibration and test of radiation protection instrumentation employed at high-energy accelerator facilities and for aircraft and space dosimetry. This paper describes the main features of the facility and supplies a non-exhaustive list of recent (as of 2005) applications for which CERF is used. Upgrade work started in 2015 to provide the scientific and industrial communities with a state-of-the-art reference facility is also discussed.
2007-04-09
JSC2007-E-18102 (9 April 2007) --- United Space Alliance (USA) crew trainer Adam Flagan (left) briefs astronaut Douglas H. Wheelock, STS-120 mission specialist, on the usage of a special pulley device, used to lower oneself from a trouble-plagued shuttle. The briefing came during an emergency egress training session in the Space Vehicle Mockup Facility at the Johnson Space Center. Wheelock is wearing a training version of his shuttle launch and entry suit.
Kennedy Space Center exercise program
NASA Technical Reports Server (NTRS)
Hoffman, Cristy
1993-01-01
The Kennedy Space Center (KSC) Fitness Program began in Feb. 1993. The program is managed by the Biomedical Operations and Research Office and operated by the Bionetics Corporation. The facilities and programs are offered to civil servants, all contractors, temporary duty assignment (TDY) participants, and retirees. All users must first have a medical clearance. A computer-generated check-in system is used to monitor participant usage. Various aspects of the program are discussed.
Shielding of medical imaging X-ray facilities: a simple and practical method.
Bibbo, Giovanni
2017-12-01
The most widely accepted method for shielding design of X-ray facilities is that contained in the National Council on Radiation Protection and Measurements Report 147 whereby the computation of the barrier thickness for primary, secondary and leakage radiations is based on the knowledge of the distances from the radiation sources, the assumptions of the clinical workload, and usage and occupancy of adjacent areas. The shielding methodology used in this report is complex. With this methodology, the shielding designers need to make assumptions regarding the use of the X-ray room and the adjoining areas. Different shielding designers may make different assumptions resulting in different shielding requirements for a particular X-ray room. A more simple and practical method is to base the shielding design on the shielding principle used to shield X-ray tube housing to limit the leakage radiation from the X-ray tube. In this case, the shielding requirements of the X-ray room would depend only on the maximum radiation output of the X-ray equipment regardless of workload, usage or occupancy of the adjacent areas of the room. This shielding methodology, which has been used in South Australia since 1985, has proven to be practical and, to my knowledge, has not led to excess shielding of X-ray installations.
2010-01-01
Background Shared-usage high throughput screening (HTS) facilities are becoming more common in academe as large-scale small molecule and genome-scale RNAi screening strategies are adopted for basic research purposes. These shared facilities require a unique informatics infrastructure that must not only provide access to and analysis of screening data, but must also manage the administrative and technical challenges associated with conducting numerous, interleaved screening efforts run by multiple independent research groups. Results We have developed Screensaver, a free, open source, web-based lab information management system (LIMS), to address the informatics needs of our small molecule and RNAi screening facility. Screensaver supports the storage and comparison of screening data sets, as well as the management of information about screens, screeners, libraries, and laboratory work requests. To our knowledge, Screensaver is one of the first applications to support the storage and analysis of data from both genome-scale RNAi screening projects and small molecule screening projects. Conclusions The informatics and administrative needs of an HTS facility may be best managed by a single, integrated, web-accessible application such as Screensaver. Screensaver has proven useful in meeting the requirements of the ICCB-Longwood/NSRB Screening Facility at Harvard Medical School, and has provided similar benefits to other HTS facilities. PMID:20482787
Tolopko, Andrew N; Sullivan, John P; Erickson, Sean D; Wrobel, David; Chiang, Su L; Rudnicki, Katrina; Rudnicki, Stewart; Nale, Jennifer; Selfors, Laura M; Greenhouse, Dara; Muhlich, Jeremy L; Shamu, Caroline E
2010-05-18
Shared-usage high throughput screening (HTS) facilities are becoming more common in academe as large-scale small molecule and genome-scale RNAi screening strategies are adopted for basic research purposes. These shared facilities require a unique informatics infrastructure that must not only provide access to and analysis of screening data, but must also manage the administrative and technical challenges associated with conducting numerous, interleaved screening efforts run by multiple independent research groups. We have developed Screensaver, a free, open source, web-based lab information management system (LIMS), to address the informatics needs of our small molecule and RNAi screening facility. Screensaver supports the storage and comparison of screening data sets, as well as the management of information about screens, screeners, libraries, and laboratory work requests. To our knowledge, Screensaver is one of the first applications to support the storage and analysis of data from both genome-scale RNAi screening projects and small molecule screening projects. The informatics and administrative needs of an HTS facility may be best managed by a single, integrated, web-accessible application such as Screensaver. Screensaver has proven useful in meeting the requirements of the ICCB-Longwood/NSRB Screening Facility at Harvard Medical School, and has provided similar benefits to other HTS facilities.
Fayette County Better Buildings Initiative
DOE Office of Scientific and Technical Information (OSTI.GOV)
Capella, Arthur
The Fayette County Better Buildings Initiative represented a comprehensive and collaborative approach to promoting and implementing energy efficiency improvements. The initiative was designed to focus on implementing energy efficiency improvements in residential units, while simultaneously supporting general marketing of the benefits of implementing energy efficiency measures. The ultimate goal of Fayette County’s Better Buildings Initiative was to implement a total of 1,067 residential energy efficiency retrofits with a minimum 15% estimated energy efficiency savings per unit. Program partners included: United States Department of Energy, Allegheny Power, and Private Industry Council of Westmoreland-Fayette, Fayette County Redevelopment Authority, and various local partners.more » The program was open to any Fayette County residents who own their home and meet the prequalifying conditions. The level of assistance offered depended upon household income and commitment to undergo a BPI – Certified Audit and implement energy efficiency measures, which aimed to result in at least a 15% reduction in energy usage. The initiative was designed to focus on implementing energy efficiency improvements in residential units, while simultaneously supporting general marketing of the benefits of implementing energy efficiency measures. Additionally, the program had components that involved recruitment and training for employment of persons in the energy sector (green jobs), as well as marketing and implementation of a commercial or community facilities component. The residential component of Fayette County’s Better Buildings Initiative involved a comprehensive approach, providing assistance to low- moderate- and market-rate homeowners. The initiative will also coordinate activities with local utility providers to further incentivize energy efficiency improvements among qualifying homeowners. The commercial component of Fayette County’s Better Building Initiative involved grants and loans to assist up to $15,000 projects per commercial structure with a mixture of a grant and financing at 0% for up to three – (3) years. The maximum award can be a $5,000 grant and a $10,000 loan. For projects less than $15,000, the award will have a ratio of 1/3 grant and 2/3 loan.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Andon, J.; Dodson, E.; Khadilkar, A.
1975-06-01
Current passenger car usage patterns and factors influencing usage are analyzed and projections of usage patterns in the mid-1980's are made. Current available data on six categories of vehicle accidents are analyzed and projections made of national accident patterns in the mid-80's; the effect of potential reductions in these projections as a result of safety programs and other factors related to driving safety are estimated. Based on the usage and accident projections, the characteristics of an RSV (weighing under 3,000 lbs C.W.) for operation in the mid-1980 traffic environment are described. A recommended set of specifications for the RSV aremore » developed considering the potential safety payoff accruing to an increased level of safety performance, the need for energy conservation, availability of material resources, and changes in vehicle mix. (An executive summary of this report is presented in Volume I).« less
After-hours Power Status of Office Equipment and Inventory of Miscellaneous Plug-load Equipment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roberson, Judy A.; Webber, Carrie A.; McWhinney, Marla C.
2004-01-22
This research was conducted in support of two branches of the EPA ENERGY STAR program, whose overall goal is to reduce, through voluntary market-based means, the amount of carbon dioxide emitted in the U.S. The primary objective was to collect data for the ENERGY STAR Office Equipment program on the after-hours power state of computers, monitors, printers, copiers, scanners, fax machines, and multi-function devices. We also collected data for the ENERGY STAR Commercial Buildings branch on the types and amounts of ''miscellaneous'' plug-load equipment, a significant and growing end use that is not usually accounted for by building energy managers.more » This data set is the first of its kind that we know of, and is an important first step in characterizing miscellaneous plug loads in commercial buildings. The main purpose of this study is to supplement and update previous data we collected on the extent to which electronic office equipment is turned off or automatically enters a low power state when not in active use. In addition, it provides data on numbers and types of office equipment, and helps identify trends in office equipment usage patterns. These data improve our estimates of typical unit energy consumption and savings for each equipment type, and enables the ENERGY STAR Office Equipment program to focus future effort on products with the highest energy savings potential. This study expands our previous sample of office buildings in California and Washington DC to include education and health care facilities, and buildings in other states. We report data from twelve commercial buildings in California, Georgia, and Pennsylvania: two health care buildings, two large offices (> 500 employees each), three medium offices (50-500 employees), four education buildings, and one ''small office'' that is actually an aggregate of five small businesses. Two buildings are in the San Francisco Bay area of California, five are in Pittsburgh, Pennsylvania, and five are in Atlanta, Georgia.« less
An intelligent switch with back-propagation neural network based hybrid power system
NASA Astrophysics Data System (ADS)
Perdana, R. H. Y.; Fibriana, F.
2018-03-01
The consumption of conventional energy such as fossil fuels plays the critical role in the global warming issues. The carbon dioxide, methane, nitrous oxide, etc. could lead the greenhouse effects and change the climate pattern. In fact, 77% of the electrical energy is generated from fossil fuels combustion. Therefore, it is necessary to use the renewable energy sources for reducing the conventional energy consumption regarding electricity generation. This paper presents an intelligent switch to combine both energy resources, i.e., the solar panels as the renewable energy with the conventional energy from the State Electricity Enterprise (PLN). The artificial intelligence technology with the back-propagation neural network was designed to control the flow of energy that is distributed dynamically based on renewable energy generation. By the continuous monitoring on each load and source, the dynamic pattern of the intelligent switch was better than the conventional switching method. The first experimental results for 60 W solar panels showed the standard deviation of the trial at 0.7 and standard deviation of the experiment at 0.28. The second operation for a 900 W of solar panel obtained the standard deviation of the trial at 0.05 and 0.18 for the standard deviation of the experiment. Moreover, the accuracy reached 83% using this method. By the combination of the back-propagation neural network with the observation of energy usage of the load using wireless sensor network, each load can be evenly distributed and will impact on the reduction of conventional energy usage.
Facility and Laboratory Equipment | Energy Systems Integration Facility |
Energy Systems Integration Facility is its infrastructure. In addition to extensive fixed laboratory . Photo of researchers testing building loads and power networks in the Systems Performance Laboratory
Facilities | Photovoltaic Research | NREL
Centers (RTCs) The Department of Energy Regional Test Centers for solar technologies serve to validate PV development to provide foundational support for the photovoltaic (PV) industry and PV users. Photo of the Solar Research Energy Facility. Solar Energy Research Facility (SERF) The SERF houses various
Code of Federal Regulations, 2011 CFR
2011-07-01
... ENERGY MANAGEMENT, REGULATION, AND ENFORCEMENT, DEPARTMENT OF THE INTERIOR OFFSHORE RENEWABLE ENERGY ALTERNATE USES OF EXISTING FACILITIES ON THE OUTER CONTINENTAL SHELF Rights of Use and Easement for Energy- and Marine-Related Activities Using Existing OCS Facilities Decommissioning An Alternate Use Rue § 285...
10 CFR 1016.8 - Approval for processing access permittees for security facility approval.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 4 2011-01-01 2011-01-01 false Approval for processing access permittees for security facility approval. 1016.8 Section 1016.8 Energy DEPARTMENT OF ENERGY (GENERAL PROVISIONS) SAFEGUARDING OF RESTRICTED DATA Physical Security § 1016.8 Approval for processing access permittees for security facility...
10 CFR 1016.8 - Approval for processing access permittees for security facility approval.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 4 2010-01-01 2010-01-01 false Approval for processing access permittees for security facility approval. 1016.8 Section 1016.8 Energy DEPARTMENT OF ENERGY (GENERAL PROVISIONS) SAFEGUARDING OF RESTRICTED DATA Physical Security § 1016.8 Approval for processing access permittees for security facility...
Thermal Distribution System | Energy Systems Integration Facility | NREL
Thermal Distribution System Thermal Distribution System The Energy Systems Integration Facility's integrated thermal distribution system consists of a thermal water loop connected to a research boiler and . Photo of the roof of the Energy Systems Integration Facility. The thermal distribution bus allows
Energy Information Abstracts Annual 1988. Volume 13.
ERIC Educational Resources Information Center
Yuster, Leigh C., Ed.; And Others
This publication is a compilation of information and resource material concerning energy for the year 1988. The first section details the coverage and usage of this volume. Section 2 contains a review of events in 1988, a compilation of statistical information, an article concerning coal flyash utilization, and a listing of conferences and events…
77 FR 33106 - Energy Conservation Program: Test Procedure for Microwave Ovens
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-05
... due to the different masses and shapes of the potatoes. DOE observed, similar to the tests for... consumer use, (2) the repeatability of energy use measurements using different food loads, and (3) consumer... ``normal usage'' and the water temperature rise of 50 degrees Celsius ([deg]C) achieves eating temperature...