Fire Hazard Assessment in Supporting Fire Protection System Design of a Chemical Process Facility
1996-08-01
CSDP/Studies/FireHaz –i– 3/28/97 FIRE HAZARD ASSESSMENT IN SUPPORTING FIRE PROTECTION SYSTEM DESIGN OF A CHEMICAL PROCESS FACILITY Ali Pezeshk...Joseph Chang, Dwight Hunt, and Peter Jahn Parsons Infrastructure & Technology Group, Inc. Pasadena, California 91124 ABSTRACT Because fires in a chemical ...Assessment in Supporting Fire Protection System Design of a Chemical Process Facility 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6
33 CFR 149.418 - What fire protection system must a helicopter fueling facility have?
Code of Federal Regulations, 2012 CFR
2012-07-01
... a helicopter fueling facility have? 149.418 Section 149.418 Navigation and Navigable Waters COAST... protection system must a helicopter fueling facility have? In addition to the portable fire extinguishers required under table 149.409, each helicopter fueling facility must have a fire protection system complying...
33 CFR 149.418 - What fire protection system must a helicopter fueling facility have?
Code of Federal Regulations, 2010 CFR
2010-07-01
... a helicopter fueling facility have? 149.418 Section 149.418 Navigation and Navigable Waters COAST... protection system must a helicopter fueling facility have? In addition to the portable fire extinguishers required under table 149.409, each helicopter fueling facility must have a fire protection system complying...
33 CFR 149.418 - What fire protection system must a helicopter fueling facility have?
Code of Federal Regulations, 2013 CFR
2013-07-01
... a helicopter fueling facility have? 149.418 Section 149.418 Navigation and Navigable Waters COAST... protection system must a helicopter fueling facility have? In addition to the portable fire extinguishers required under Table 149.409 of this part, each helicopter fueling facility must have a fire protection...
33 CFR 149.418 - What fire protection system must a helicopter fueling facility have?
Code of Federal Regulations, 2014 CFR
2014-07-01
... a helicopter fueling facility have? 149.418 Section 149.418 Navigation and Navigable Waters COAST... protection system must a helicopter fueling facility have? In addition to the portable fire extinguishers required under Table 149.409 of this part, each helicopter fueling facility must have a fire protection...
33 CFR 149.418 - What fire protection system must a helicopter fueling facility have?
Code of Federal Regulations, 2011 CFR
2011-07-01
... a helicopter fueling facility have? 149.418 Section 149.418 Navigation and Navigable Waters COAST... protection system must a helicopter fueling facility have? In addition to the portable fire extinguishers required under table 149.409, each helicopter fueling facility must have a fire protection system complying...
36 CFR 1234.12 - What are the fire safety requirements that apply to records storage facilities?
Code of Federal Regulations, 2012 CFR
2012-07-01
... records storage facilities? (a) The fire detection and protection systems must be designed or reviewed by a licensed fire protection engineer. If the system was not designed by a licensed fire protection... engineer that describes the design intent of the fire detection and suppression system, detailing the...
36 CFR 1234.12 - What are the fire safety requirements that apply to records storage facilities?
Code of Federal Regulations, 2014 CFR
2014-07-01
... records storage facilities? (a) The fire detection and protection systems must be designed or reviewed by a licensed fire protection engineer. If the system was not designed by a licensed fire protection... engineer that describes the design intent of the fire detection and suppression system, detailing the...
36 CFR § 1234.12 - What are the fire safety requirements that apply to records storage facilities?
Code of Federal Regulations, 2013 CFR
2013-07-01
... records storage facilities? (a) The fire detection and protection systems must be designed or reviewed by a licensed fire protection engineer. If the system was not designed by a licensed fire protection... engineer that describes the design intent of the fire detection and suppression system, detailing the...
Maintenance Facilities for Ammunition, Explosives, and Toxics. Design Manual 28.3.
1981-11-01
LOADING DOCK RAMP PROTECTION 28.3-2 8. FIRE PROTECTION 28.3-2 9. SECURITY 28.3-2 10. SAFETY 28.3-2 Section 2. GENERAL AMMUNITION MAINTENANCE SHOPS 28.3...protection in accordance with Section 3 1910.23c, Occupatioual Safety and Health Act Standards Manual. 5 8. FIRE PROTECTION. Fire protection for all...Volume 1, and Fire Protection Engineering, NAVFAC DM-8. 9. SECURITY. Maintenance facilities for ammunition, explosives, and I toxics shall be located so
36 CFR 1234.10 - What are the facility requirements for all records storage facilities?
Code of Federal Regulations, 2014 CFR
2014-07-01
... the HVAC systems, fire alarm and fire protection systems. Manual switching between sources of service... elements are protected by a properly installed, properly maintained wet-pipe automatic sprinkler system, as... must provide documentation that the facility has a fire suppression system specifically designed to...
33 CFR 127.1507 - Water systems for fire protection.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Water systems for fire protection... HAZARDOUS GAS Waterfront Facilities Handling Liquefied Hazardous Gas Firefighting Equipment § 127.1507 Water systems for fire protection. (a) Each waterfront facility handling LHG must have a supply of water and a...
Compressed Natural Gas Vehicle Maintenance Facility Modification Handbook
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kelly, K.; Melendez, M.; Gonzales, J.
To ensure the safety of personnel and facilities, vehicle maintenance facilities are required by law and by guidelines of the National Fire Protection Association (NFPA) and the International Fire Code (IFC) to exhibit certain design features. They are also required to be fitted with certain fire protection equipment and devices because of the potential for fire or explosion in the event of fuel leakage or spills. All fuels have an explosion or fire potential if specific conditions are present. This handbook covers the primary elements that must be considered when developing a CNG vehicle maintenance facility design that will protectmore » against the ignition of natural gas releases. It also discusses specific protocols and training needed to ensure safety.« less
Compressed Natural Gas Vehicle Maintenance Facility Modification Handbook
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kelly, Kay L.; Ramsden, Margo M.; Gonzales, John E.
To ensure the safety of personnel and facilities, vehicle maintenance facilities are required by law and by guidelines of the National Fire Protection Association (NFPA) and the International Fire Code (IFC) to exhibit certain design features. They are also required to be fitted with certain fire protection equipment and devices because of the potential for fire or explosion in the event of fuel leakage or spills. All fuels have an explosion or fire potential if specific conditions are present. The hazard presented by liquid fuels, such as gasoline and diesel, results from the spillage of these liquids and subsequent ignitionmore » of vapors, causing a fire or explosion. Facilities that maintain liquid-fueled vehicles and implement appropriate safety measures are protected with ventilation systems designed to capture liquid fuel vapors at or near floor level. To minimize the potential for ignition in the event of a spill, receptacles, electrical fixtures, and hot-work operations, such as welding, are located outside of these areas. Compressed natural gas (CNG) is composed of methane with slight amounts of heavier simple hydrocarbons. Maintenance facilities that maintain CNG vehicles indoors must be protected against fire and explosion. However, the means of ensuring safety are different from those employed for liquid fuels because of the gaseous nature of methane and the fact that it is lighter than air. Because CNG is lighter than air, a release will rise to the ceiling of the maintenance facility and quickly dissipate rather than remaining at or near floor level like liquid fuel vapors. Although some of the means of protection for CNG vehicle maintenance facilities are similar to those used for liquid-fueled vehicles (ventilation and elimination of ignition sources), the types and placement of the protection equipment are different because of the behavior of the different fuels. The nature of gaseous methane may also require additional safeguards, such as combustible gas detectors and control systems, or specialized space heating, which are not needed in facilities servicing liquid-fuel vehicles. This handbook covers maintenance facilities that service CNG-fueled vehicles. Although similar requirements are mandated for liquefied natural gas (LNG) or liquefied petroleum gas (LPG) fueled vehicles, LNG and LPG are not covered in this handbook.« less
Code of Federal Regulations, 2010 CFR
2010-01-01
... could occur in a nuclear power plant. These sessions shall provide brigade members with experience in... A. Fire protection program. A fire protection program shall be established at each nuclear power... fires that could occur in the plant and in using the types of equipment available in the nuclear power...
Fire hazard analysis for Plutonium Finishing Plant complex
DOE Office of Scientific and Technical Information (OSTI.GOV)
MCKINNIS, D.L.
1999-02-23
A fire hazards analysis (FHA) was performed for the Plutonium Finishing Plant (PFP) Complex at the Department of Energy (DOE) Hanford site. The scope of the FHA focuses on the nuclear facilities/structures in the Complex. The analysis was conducted in accordance with RLID 5480.7, [DOE Directive RLID 5480.7, 1/17/94] and DOE Order 5480.7A, ''Fire Protection'' [DOE Order 5480.7A, 2/17/93] and addresses each of the sixteen principle elements outlined in paragraph 9.a(3) of the Order. The elements are addressed in terms of the fire protection objectives stated in paragraph 4 of DOE 5480.7A. In addition, the FHA also complies with WHC-CM-4-41,more » Fire Protection Program Manual, Section 3.4 [1994] and WHC-SD-GN-FHA-30001, Rev. 0 [WHC, 1994]. Objectives of the FHA are to determine: (1) the fire hazards that expose the PFP facilities, or that are inherent in the building operations, (2) the adequacy of the fire safety features currently located in the PFP Complex, and (3) the degree of compliance of the facility with specific fire safety provisions in DOE orders, related engineering codes, and standards.« less
Fire Incident Reporting Manual
1984-02-01
Purpose 1-1 B. Scope 1-1 C. Procedures 1-1 D. Exclusions 1-3 E . Preparation 1-3 F. Information Requirements 1-4 CHAPTER 2 - INSTRUCTIONS FOR PREPARING DoD...Structure and Fire Data 2-16 4. Section D - Fire Protection Facilities (In Structures Only) 2-28 5. Section E - Losses 2-30 6. Section F - Times (24...Activities Program," February 21, 1976 ( e ) National Fire Protection Association (NFPA) Standard 901, "Uniform Coding for Fire Protection," 1976 (f) NFPA
Fire protection review revisit no. 2, Argonne National Laboratory, Argonne, Illinois
NASA Astrophysics Data System (ADS)
Dobson, P. H.; Earley, M. W.; Mattern, L. J.
1985-05-01
A fire protection survey was conducted at Argonne National Laboratory on April 1-5, 8-12, and April 29-May 2, 1985. The purpose was to review the facility fire protection program and to make recommendations or identify areas according to criteria established by the Department of Energy. There has been a substantial improvement in fire protection at this laboratory since the 1977 audit. Numerous areas which were previously provided with detection systems only have since been provided with automatic sprinkler protection. The following basic fire protection features are not properly controlled: (1) resealing wall and floor penetrations between fire areas after installation of services; (2) cutting and welding; and (3) housekeeping. The present Fire Department manpower level appears adequate to control a route fire. Their ability to adequately handle a high-challenge fire, or one involving injuries to personnel, or fire spread beyond the initial fire area is doubtful.
2013-03-08
applicable fire protection standards for two of the three projects we reviewed that required a fire sprinkler system . Specifically, the Secure...RSOI and Command and Control facilities do not have fire sprinkler systems as required by Unified Facilities Criteria 3-600-01, Section 4-2.2...stated that, as such, those facilities did not need fire sprinkler systems . Based on the justification provided by the Air Force on the DD Form 1391s
49 CFR 193.2611 - Fire protection.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 3 2010-10-01 2010-10-01 false Fire protection. 193.2611 Section 193.2611 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY LIQUEFIED NATURAL GAS FACILITIES...
Unified Facilities Criteria (UFC) Design: Fire Protection Engineering for Facilities
2003-08-20
following provisions: • Ceiling sprinkler design area must be increased by 10 percent. ESFR sprinklers must increase the required number to be...Control System ESFR Early Suppression Fast-Response Sprinklers ETL Engineering Technical Letters FAAA Fire Administration Authorization Act FM
Research Summary Multipollutant Control Research Facility (MPCRF)
The U.S. Environmental Protection Agency’s (EPA) Multipollutant Control Research Facility (MPCRF) is located at their Research Triangle Park, North Carolina, campus. The MPCRF combustor is a pulverized coal-, natural gas-, and biomass-fired furnace with a maximum firing rate of 4...
Operations of cleanrooms during a forest fire including protocols and monitoring results
NASA Astrophysics Data System (ADS)
Matheson, Bruce A.; Egges, Joanne; Pirkey, Michael S.; Lobmeyer, Lynette D.
2012-10-01
Contamination-sensitive space flight hardware is typically built in cleanroom facilities in order to protect the hardware from particle contamination. Forest wildfires near the facilities greatly increase the number of particles and amount of vapors in the ambient outside air. Reasonable questions arise as to whether typical cleanroom facilities can adequately protect the hardware from these adverse environmental conditions. On Monday September 6, 2010 (Labor Day Holiday), a large wildfire ignited near the Boulder, Colorado Campus of Ball Aerospace. The fire was approximately 6 miles from the Boulder City limits. Smoke levels from the fire stayed very high in Boulder for the majority of the week after the fire began. Cleanroom operations were halted temporarily on contamination sensitive hardware, until particulate and non-volatile residue (NVR) sampling could be performed. Immediate monitoring showed little, if any effect on the cleanroom facilities, so programs were allowed to resume work while monitoring continued for several days and beyond in some cases. Little, if any, effect was ever noticed in the monitoring performed.
Tseng, Wei-Wen; Shih, Chung-Liang; Chien, Shen-Wen
2013-04-01
Taiwan's worst hospital fire in history on October 23rd, 2012 at Sinying Hospital's Bei-Men Branch resulted in 13 elderly patient deaths and over 70 injuries. The heavy casualties were due in part to the serious condition of patients. Some patients on life-support machines were unable to move or be moved. This disaster highlights the issue of fire safety in small-scale hospitals that have transformed existing hospital space into special care environments for elderly patients. Compared with medical centers and general hospitals, these small-scale health facilities are ill equipped to deal properly with fire safety management and emergency response issues due to inadequate fire protection facilities, fire safety equipment, and human resources. Small-scale facilities that offer health care and medical services to mostly immobile patients face fire risks that differ significantly from general health care facilities. This paper focuses on fire risks in small-scale facilities and suggests a strategy for fire prevention and emergency response procedures, including countermeasures for fire risk assessment, management, and emergency response, in order to improve fire safety at these institutions in Taiwan.
29 CFR 1915.505 - Fire response.
Code of Federal Regulations, 2011 CFR
2011-07-01
... written standard operating procedures for each type of fire response at the employer's facility; (v) The... suppression operations established by written standard operating procedures for each particular type of fire...) OCCUPATIONAL SAFETY AND HEALTH STANDARDS FOR SHIPYARD EMPLOYMENT Fire Protection in Shipyard Employment § 1915...
29 CFR 1915.505 - Fire response.
Code of Federal Regulations, 2013 CFR
2013-07-01
... written standard operating procedures for each type of fire response at the employer's facility; (v) The... suppression operations established by written standard operating procedures for each particular type of fire...) OCCUPATIONAL SAFETY AND HEALTH STANDARDS FOR SHIPYARD EMPLOYMENT Fire Protection in Shipyard Employment § 1915...
29 CFR 1915.505 - Fire response.
Code of Federal Regulations, 2012 CFR
2012-07-01
... written standard operating procedures for each type of fire response at the employer's facility; (v) The... suppression operations established by written standard operating procedures for each particular type of fire...) OCCUPATIONAL SAFETY AND HEALTH STANDARDS FOR SHIPYARD EMPLOYMENT Fire Protection in Shipyard Employment § 1915...
29 CFR 1915.505 - Fire response.
Code of Federal Regulations, 2010 CFR
2010-07-01
... written standard operating procedures for each type of fire response at the employer's facility; (v) The... suppression operations established by written standard operating procedures for each particular type of fire...) OCCUPATIONAL SAFETY AND HEALTH STANDARDS FOR SHIPYARD EMPLOYMENT Fire Protection in Shipyard Employment § 1915...
29 CFR 1915.505 - Fire response.
Code of Federal Regulations, 2014 CFR
2014-07-01
... written standard operating procedures for each type of fire response at the employer's facility; (v) The... suppression operations established by written standard operating procedures for each particular type of fire...) OCCUPATIONAL SAFETY AND HEALTH STANDARDS FOR SHIPYARD EMPLOYMENT Fire Protection in Shipyard Employment § 1915...
Test results: Halon 1301 versus water sprinkler fire protection for essential electronic equipment
NASA Astrophysics Data System (ADS)
Reichelt, E. F.; Walker, J. L.; Vickers, R. N.; Kwan, A. J.
1982-07-01
This report describes results of testing two contending extinguishants, Halon 1301 and water, for fire protection of essential electronic equipment. A series of controlled fires in a facility housing an operational electronic data processing system sought to establish immediate and long term effects of exposure of sensitive electronic equipment and stored data to fire extinguishment atmospheres. Test results lead to the conclusion that Halon 1301 is superior to water as an extinguishant for fires occurring in essential electronic equipment installations.
49 CFR 192.171 - Compressor stations: Additional safety equipment.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 3 2011-10-01 2011-10-01 false Compressor stations: Additional safety equipment... Pipeline Components § 192.171 Compressor stations: Additional safety equipment. (a) Each compressor station must have adequate fire protection facilities. If fire pumps are a part of these facilities, their...
Military Housing Inspection-Camp Buehring, Kuwait
2016-09-30
General DPW Director Public Works FAS Fire Alarm System HVAC Heating, Ventilation, and Air Conditioning IAW In Accordance With ITM Inspection...safety policies and standards regarding electrical and fire protection systems . Findings We found significant deficiencies in electrical and fire...protection systems during the physical inspections of the U.S. military-occupied facilities at Camp Buehring. We identified a total of 538
Fire protection for launch facilities using machine vision fire detection
NASA Astrophysics Data System (ADS)
Schwartz, Douglas B.
1993-02-01
Fire protection of critical space assets, including launch and fueling facilities and manned flight hardware, demands automatic sensors for continuous monitoring, and in certain high-threat areas, fast-reacting automatic suppression systems. Perhaps the most essential characteristic for these fire detection and suppression systems is high reliability; in other words, fire detectors should alarm only on actual fires and not be falsely activated by extraneous sources. Existing types of fire detectors have been greatly improved in the past decade; however, fundamental limitations of their method of operation leaves open a significant possibility of false alarms and restricts their usefulness. At the Civil Engineering Laboratory at Tyndall Air Force Base in Florida, a new type of fire detector is under development which 'sees' a fire visually, like a human being, and makes a reliable decision based on known visual characteristics of flames. Hardware prototypes of the Machine Vision (MV) Fire Detection System have undergone live fire tests and demonstrated extremely high accuracy in discriminating actual fires from false alarm sources. In fact, this technology promises to virtually eliminate false activations. This detector could be used to monitor fueling facilities, launch towers, clean rooms, and other high-value and high-risk areas. Applications can extend to space station and in-flight shuttle operations as well; fiber optics and remote camera heads enable the system to see around obstructed areas and crew compartments. The capability of the technology to distinguish fires means that fire detection can be provided even during maintenance operations, such as welding.
Fire protection for launch facilities using machine vision fire detection
NASA Technical Reports Server (NTRS)
Schwartz, Douglas B.
1993-01-01
Fire protection of critical space assets, including launch and fueling facilities and manned flight hardware, demands automatic sensors for continuous monitoring, and in certain high-threat areas, fast-reacting automatic suppression systems. Perhaps the most essential characteristic for these fire detection and suppression systems is high reliability; in other words, fire detectors should alarm only on actual fires and not be falsely activated by extraneous sources. Existing types of fire detectors have been greatly improved in the past decade; however, fundamental limitations of their method of operation leaves open a significant possibility of false alarms and restricts their usefulness. At the Civil Engineering Laboratory at Tyndall Air Force Base in Florida, a new type of fire detector is under development which 'sees' a fire visually, like a human being, and makes a reliable decision based on known visual characteristics of flames. Hardware prototypes of the Machine Vision (MV) Fire Detection System have undergone live fire tests and demonstrated extremely high accuracy in discriminating actual fires from false alarm sources. In fact, this technology promises to virtually eliminate false activations. This detector could be used to monitor fueling facilities, launch towers, clean rooms, and other high-value and high-risk areas. Applications can extend to space station and in-flight shuttle operations as well; fiber optics and remote camera heads enable the system to see around obstructed areas and crew compartments. The capability of the technology to distinguish fires means that fire detection can be provided even during maintenance operations, such as welding.
49 CFR 192.171 - Compressor stations: Additional safety equipment.
Code of Federal Regulations, 2010 CFR
2010-10-01
... SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Design of... must have adequate fire protection facilities. If fire pumps are a part of these facilities, their... event of inadequate cooling or lubrication of the unit. (d) Each compressor station gas engine that...
Occupancy Fire Record: Schools.
ERIC Educational Resources Information Center
National Fire Protection Association, Boston, MA.
The considerations of human safety and preservation of facilities are examined in relation to school fires. Various aspects of planning which would decrease the probability of fires and thereby save life and property are reviewed and include--(1) causes, (2) automatic protection devices, (3) evacuation and fire drills, and (4) construction…
Audit Report, "Fire Protection Deficiencies at Los Alamos National Laboratory"
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2009-06-01
The Department of Energy's Los Alamos National Laboratory (Los Alamos) maintains some of the Nation's most important national security assets, including nuclear materials. Many of Los Alamos' facilities are located in close proximity to one another, are occupied by large numbers of contract and Federal employees, and support activities ranging from nuclear weapons design to science-related activities. Safeguarding against fires, regardless of origin, is essential to protecting employees, surrounding communities, and national security assets. On June 1, 2006, Los Alamos National Security, LLC (LANS), became the managing and operating contractor for Los Alamos, under contract with the Department's National Nuclearmore » Security Administration (NNSA). In preparation for assuming its management responsibilities at Los Alamos, LANS conducted walk-downs of the Laboratory's facilities to identify pre-existing deficiencies that could give rise to liability, obligation, loss or damage. The walk-downs, which identified 812 pre-existing fire protection deficiencies, were conducted by subject matter professionals, including fire protection experts. While the Los Alamos Site Office has overall responsibility for the effectiveness of the fire protection program, LANS, as the Laboratory's operating contractor, has a major, day-to-day role in minimizing fire-related risks. The issue of fire protection at Los Alamos is more than theoretical. In May 2000, the 'Cerro Grande' fire burned about 43,000 acres, including 7,700 acres of Laboratory property. Due to the risk posed by fire to the Laboratory's facilities, workforce, and surrounding communities, we initiated this audit to determine whether pre-existing fire protection deficiencies had been addressed. Our review disclosed that LANS had not resolved many of the fire protection deficiencies that had been identified in early 2006: (1) Of the 296 pre-existing deficiencies we selected for audit, 174 (59 percent) had not been corrected; and, (2) A substantial portion of the uncorrected deficiencies, 86 (49 percent) were considered by the walk-down teams to be significant enough to warrant compensatory actions until the deficiency was corrected or was tracked to closure through implementation of corrective actions. Further, we found that 32 of the significant deficiencies had been closed by the previous Los Alamos contractor, prior to LANS assuming responsibility for operation of the Laboratory, even though the deficiencies had not been corrected. A fire protection expert provided technical support during the audit. As an example of uncorrected problems, LANS had not resolved, by performing periodic tests, a deficiency identified in 2006 regarding a kitchen hood fire suppression system in a facility located within the Los Alamos Neutron Science Center. Such systems are required to be tested twice a year by the National Fire Protection Association standard, a standard that had been adopted by Department of Energy under DOE Order 420.1B. Yet, in 2006, the LANS walk-down team recognized that this system had not been inspected since May 2004 and noted that deficient suppression systems could result in significantly high levels of property damage and loss. After we brought this issue to management's attention on February 6, 2009, LANS officials stated that the Laboratory would correct this deficiency. As with the problems involving the fire suppression system, we observed that LANS had not always corrected life safety deficiencies involving building exits at one of its primary facilities. This included providing a secondary emergency exit for a building with occupants on multiple floor levels. LANS had removed personnel from the third floor and improved the sprinkler system of the facility, but it had still not provided a secondary exit for personnel on the second floor by the time we completed our review. NNSA has since stated that this fire protection issue will be completely addressed by relocating personnel from the second floor. Perhaps most serious, our testing revealed that a number of deficiencies were formally closed even though actual corrective action had not been completed. Notably, we observed that action had not been taken to resolve a recommendation to replace a fire alarm panel found to be unreliable. After the walk-down was conducted but prior to contract transition, the former contractor closed the recommendation in its action tracking database even though the panel had not been replaced. The walk-down team had categorized the fire alarm system as requiring replacement since it had been modified many times, was old and obsolete, and had very limited available spare parts. In fact, the walk-down team concluded that the panel 'must be considered to be unreliable and should have a very high priority for replacement'.« less
Ten Fire Safety Tips for Schools.
ERIC Educational Resources Information Center
Lake, James D.
1999-01-01
Provides 10 basic tips, compiled from the National Fire Protection Association's Life Safety Code 101, to ensure that educational facilities are fire safe. Tips include use of frequent and unexpected fire drills, limiting wall space of student artwork and teaching materials, being alert to preventing arson, planning speedy and safe emergency…
Station set requirements document. Volume 82: Fire support. Book 2: Preliminary functional fire plan
NASA Technical Reports Server (NTRS)
Gray, N. C.
1974-01-01
The fire prevention/protection requirements for all shuttle facility and ground support equipment are presented for the hazardous operations. These include: preparing the orbiter for launch, launch operations, landing operations, safing operations, and associated off-line activities.
2014-03-06
CAPE CANAVERAL, Fla. - Special Rescue Operations firefighters with NASA Fire Rescue Services in the Protective Services Office at NASA’s Kennedy Space Center in Florida participate in a training exercise at the Shuttle Landing Facility. Firefighters, wearing protective gear, use hoses to put out a fire burning close to a mock-up of a small plane. Kennedy’s firefighters recently achieved Pro Board Certification in aerial fire truck operations and completed vehicle extrication training using the Jaws of Life. The Protective Services Office is one step closer to achieving certification in vehicle machinery extrication and other rescue skills. Kennedy’s firefighters are with G4S Government Solutions Inc., on the Kennedy Protective Services Contract. Photo credit: NASA/Kim Shiflett
2014-03-06
CAPE CANAVERAL, Fla. - Special Rescue Operations firefighters with NASA Fire Rescue Services in the Protective Services Office at NASA’s Kennedy Space Center in Florida participate in a training exercise at the Shuttle Landing Facility. Firefighters, wearing protective gear, use hoses to put out a fire burning near the mock-up of a small plane. Kennedy’s firefighters recently achieved Pro Board Certification in aerial fire truck operations and completed vehicle extrication training using the Jaws of Life. The Protective Services Office is one step closer to achieving certification in vehicle machinery extrication and other rescue skills. Kennedy’s firefighters are with G4S Government Solutions Inc., on the Kennedy Protective Services Contract. Photo credit: NASA/Kim Shiflett
2014-03-06
CAPE CANAVERAL, Fla. - Special Rescue Operations firefighters with NASA Fire Rescue Services in the Protective Services Office at NASA’s Kennedy Space Center in Florida participate in a training exercise at the Shuttle Landing Facility. Firefighters, wearing protective gear, use hoses to put out a fire burning on a mock-up of a small plane. Kennedy’s firefighters recently achieved Pro Board Certification in aerial fire truck operations and completed vehicle extrication training using the Jaws of Life. The Protective Services Office is one step closer to achieving certification in vehicle machinery extrication and other rescue skills. Kennedy’s firefighters are with G4S Government Solutions Inc., on the Kennedy Protective Services Contract. Photo credit: NASA/Kim Shiflett
2014-03-06
CAPE CANAVERAL, Fla. - During a training exercise, Special Rescue Operations firefighters with NASA Fire Rescue Services in the Protective Services Office at NASA’s Kennedy Space Center in Florida use hoses to put out a fire burning on a mock-up of a small plane at the Shuttle Landing Facility. They are wearing protective gear for the training exercise. Kennedy’s firefighters recently achieved Pro Board Certification in aerial fire truck operations and completed vehicle extrication training using the Jaws of Life. The Protective Services Office is one step closer to achieving certification in vehicle machinery extrication and other rescue skills. Kennedy’s firefighters are with G4S Government Solutions Inc., on the Kennedy Protective Services Contract. Photo credit: NASA/Kim Shiflett
2014-03-06
CAPE CANAVERAL, Fla. - Special Rescue Operations firefighters with NASA Fire Rescue Services in the Protective Services Office at NASA’s Kennedy Space Center in Florida participate in a training exercise at the Shuttle Landing Facility. Firefighters use a fire truck to put out a fire burning close to a mock-up of a small plane and a truck. Kennedy’s firefighters recently achieved Pro Board Certification in aerial fire truck operations and completed vehicle extrication training using the Jaws of Life. The Protective Services Office is one step closer to achieving certification in vehicle machinery extrication and other rescue skills. Kennedy’s firefighters are with G4S Government Solutions Inc., on the Kennedy Protective Services Contract. Photo credit: NASA/Kim Shiflett
75 FR 35437 - Notice of Request for Extension of a Currently Approved Information Collection
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-22
... from construction of a fire station with fire fighting and rescue equipment to financing a 911 emergency system. These facilities are designed to provide fire protection and emergency rescue services to... for a currently approved information collection in support of the program for Fire and Rescue Loans...
2014-03-06
CAPE CANAVERAL, Fla. - Special Rescue Operations firefighters with NASA Fire Rescue Services in the Protective Services Office at NASA’s Kennedy Space Center in Florida practice firefighting skills at the Shuttle Landing Facility. A firefighter dons protective gear to prepare for the training simulation. Kennedy’s firefighters recently achieved Pro Board Certification in aerial fire truck operations and completed vehicle extrication training using the Jaws of Life. The Protective Services Office is one step closer to achieving certification in vehicle machinery extrication and other rescue skills. Kennedy’s firefighters are with G4S Government Solutions Inc., on the Kennedy Protective Services Contract. Photo credit: NASA/Kim Shiflett
Remote monitoring of a Fire Protection System
NASA Astrophysics Data System (ADS)
Bauman, Steven; Vermeulen, Tom; Roberts, Larry; Matsushige, Grant; Gajadhar, Sarah; Taroma, Ralph; Elizares, Casey; Arruda, Tyson; Potter, Sharon; Hoffman, James
2011-03-01
Some years ago CFHT proposed developing a Remote Observing Environment aimed at producing Science Observations at their Observatory Facility on Mauna Kea from their Headquarters facility in Waimea, HI. This Remote Observing Project commonly referred to as OAP (Observatory Automation Project) was completed at the end of January 2011 and has been providing the majority of Science Data since. My poster will discuss the upgrades to the existing fire alarm protection system. With no one at the summit during nightly operations, the observatory facility required automated monitoring of the facility for safety to personnel and equipment in the case of a fire. An addressable analog fire panel was installed which utilizes digital communication protocol (DCP), intelligent communication with other devices, and an RS-232 interface which provides feedback and real-time monitoring of the system. Using the interface capabilities of the panel, it provides notifications when heat detectors, smoke sensors, manual pull stations, or the main observatory computer room fire suppression system has been activated. The notifications are sent out as alerts to staff in the form of test massages and emails and the observing control GUI interface alerts the remote telescope operator with a map showing the location of the fire occurrence and type of device that has been triggered. And all of this was accomplished without the need for an outside vendor to monitor the system and facilitate warnings or notifications regarding the system.
Aviation Engine Test Facilities (AETF) fire protection study
NASA Astrophysics Data System (ADS)
Beller, R. C.; Burns, R. E.; Leonard, J. T.
1989-07-01
An analysis is presented to the effectiveness of various types of fire fighting agents in extinguishing the kinds of fires anticipated in Aviation Engine Test Facilities (AETF), otherwise known as Hush Houses. The agents considered include Aqueous Film-Forming Foam, Halon 1301, Halon 1211 and water. Previous test work has shown the rapidity with which aircraft, especially high performance aircraft, can be damaged by fire. Based on this, tentative criteria for this evaluation included a maximum time of 20 s from fire detection to extinguishment and a period of 30 min in which the agent would prevent reignition. Other issues examined included: toxicity, corrosivity, ease of personnel egress, system reliability, and cost effectiveness. The agents were evaluated for their performance in several fire scenarios, including: under frame fire, major engine fire, engine disintegration fire, high-volume pool fire with simultaneous spill fire, internal electrical fire, and runaway engine fire.
2014-03-06
CAPE CANAVERAL, Fla. - Special Rescue Operations firefighters with NASA Fire Rescue Services in the Protective Services Office at NASA’s Kennedy Space Center in Florida participate in a training exercise at the Shuttle Landing Facility. Firefighters, wearing protective gear, use hoses to put out a fire burning near the mock-up of a small plane as another firefighter checks inside the plane. Kennedy’s firefighters recently achieved Pro Board Certification in aerial fire truck operations and completed vehicle extrication training using the Jaws of Life. The Protective Services Office is one step closer to achieving certification in vehicle machinery extrication and other rescue skills. Kennedy’s firefighters are with G4S Government Solutions Inc., on the Kennedy Protective Services Contract. Photo credit: NASA/Kim Shiflett
46 CFR 108.486 - Helicopter decks.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Helicopter decks. 108.486 Section 108.486 Shipping COAST... Fire Extinguishing Systems Fire Protection for Helicopter Facilities § 108.486 Helicopter decks. At least two of the accesses to the helicopter landing deck must each have a fire hydrant on the unit's...
46 CFR 108.486 - Helicopter decks.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Helicopter decks. 108.486 Section 108.486 Shipping COAST... Fire Extinguishing Systems Fire Protection for Helicopter Facilities § 108.486 Helicopter decks. At least two of the accesses to the helicopter landing deck must each have a fire hydrant on the unit's...
46 CFR 108.486 - Helicopter decks.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Helicopter decks. 108.486 Section 108.486 Shipping COAST... Fire Extinguishing Systems Fire Protection for Helicopter Facilities § 108.486 Helicopter decks. At least two of the accesses to the helicopter landing deck must each have a fire hydrant on the unit's...
46 CFR 108.486 - Helicopter decks.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Helicopter decks. 108.486 Section 108.486 Shipping COAST... Fire Extinguishing Systems Fire Protection for Helicopter Facilities § 108.486 Helicopter decks. At least two of the accesses to the helicopter landing deck must each have a fire hydrant on the unit's...
46 CFR 108.486 - Helicopter decks.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Helicopter decks. 108.486 Section 108.486 Shipping COAST... Fire Extinguishing Systems Fire Protection for Helicopter Facilities § 108.486 Helicopter decks. At least two of the accesses to the helicopter landing deck must each have a fire hydrant on the unit's...
Safety engineering in handling fuels and lubricants in civil aviation
NASA Astrophysics Data System (ADS)
Protoereiskii, Aleksandr Stepanovich
The book is concerned with methods of improving working conditions, work hygiene, safety engineering, and fire and explosion prevention during the storage and handling of petroleum products at fuel and lubricant storage facilities. The discussion covers methods of protection against static and atmospheric discharges, lightning protection, safety engineering in fuel and lubricant laboratories, and methods of fire prevention and fire extinction. Attention is also given to methods for administering first aid in case of accidents and poisoning.
Updating fire safety standards. Final rule; affirmation.
2011-11-16
This document affirms as final, without changes, a provision included in a final rule with request for comments that amended the Department of Veterans Affairs (VA) regulations concerning community residential care facilities, contract facilities for certain outpatient and residential services, and State home facilities. That provision established a five-year period within which all covered buildings with nursing home facilities existing as of June 25, 2001, must conform to the automatic sprinkler requirement of the 2009 edition of the National Fire Protection Association (NFPA) 101. This rule helps ensure the safety of veterans in the affected facilities.
2014-03-06
CAPE CANAVERAL, Fla. - Special Rescue Operations firefighters with NASA Fire Rescue Services in the Protective Services Office at NASA’s Kennedy Space Center in Florida prepare to participate in a training exercise at the Shuttle Landing Facility. A small fire is burning near a mock-up of a plane during the training exercise. Kennedy’s firefighters recently achieved Pro Board Certification in aerial fire truck operations and completed vehicle extrication training using the Jaws of Life. The Protective Services Office is one step closer to achieving certification in vehicle machinery extrication and other rescue skills. Kennedy’s firefighters are with G4S Government Solutions Inc., on the Kennedy Protective Services Contract. Photo credit: NASA/Kim Shiflett
2014-03-06
CAPE CANAVERAL, Fla. - Special Rescue Operations firefighters with NASA Fire Rescue Services in the Protective Services Office at NASA’s Kennedy Space Center in Florida participate in a training exercise at the Shuttle Landing Facility. Firefighters use fire trucks and hoses to extinguish flames burning on and around a mock-up of a small plane. Kennedy’s firefighters recently achieved Pro Board Certification in aerial fire truck operations and completed vehicle extrication training using the Jaws of Life. The Protective Services Office is one step closer to achieving certification in vehicle machinery extrication and other rescue skills. Kennedy’s firefighters are with G4S Government Solutions Inc., on the Kennedy Protective Services Contract. Photo credit: NASA/Kim Shiflett
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-10
..., Classified information, Criminal penalties, Fire protection, Intergovernmental relations, Nuclear power plants and reactors, Radiation protection, Reactor siting criteria, Reporting and recordkeeping...
Fire Protection for Munitions in Underground Storage Facilities
2001-12-01
ESFR ) K-25, 165 F (74 C) sprinkler heads, manufactured by Tyco, to provide a discharge density of 0.6 gpm/ft2 (24.4 lpm/m2). The system consisted of...extinguish the fire before adjacent stacks were impacted. Results showed that ESFR K-25 pendant sprinkler heads will operate and inhibit fire spread
30 CFR 57.4160 - Underground electric substations and liquid storage facilities.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and Control Prohibitions/precautions/housekeeping § 57.4160... noncombustible materials with equivalent fire protection characteristics. ...
Fire safety design of a mobile quarantine facility
NASA Technical Reports Server (NTRS)
Bass, R. S.; Hirasaki, J. K.
1971-01-01
During the design phase of the Mobile Quarantine Facility (MQF), a primary consideration was fire safety. Therefore, appropriate criteria and ground rules were used in the design and construction of the facility. The fire codes and fire-requirement listings that are used by commerical airlines were supplied to the Manned Spacecraft Center (MSC) by the Federal Aviation Agency (FAA). After these codes were reviewed, a basic ground rule was adopted that flame protection for all combustible materials should be at least equivalent to or better than the standards for commercial aircraft. Because the MQF was designed to operate with an interior atmosphere of air rather than with an oxygen-enriched atmosphere such as that of the Apollo spacecraft cabin, the requirements for MQF material were not as stringent as those for the spacecraft.
2014-03-06
CAPE CANAVERAL, Fla. - Special Rescue Operations firefighters with NASA Fire Rescue Services in the Protective Services Office at NASA’s Kennedy Space Center in Florida review procedures after participating in a training exercise at the Shuttle Landing Facility. During the training simulation, firefighters used fire trucks and hoses to extinguish flames burning on and around a mock-up of a small plane. Kennedy’s firefighters recently achieved Pro Board Certification in aerial fire truck operations and completed vehicle extrication training using the Jaws of Life. The Protective Services Office is one step closer to achieving certification in vehicle machinery extrication and other rescue skills. Kennedy’s firefighters are with G4S Government Solutions Inc., on the Kennedy Protective Services Contract. Photo credit: NASA/Kim Shiflett
NASA Technical Reports Server (NTRS)
1980-01-01
Avco has drawn upon its heat shield experience to develop a number of widely-accepted commercial fire protection materials. Originating from NASA's space shuttle thermal protection system, one such material is Chartek 59 fireproofing, an intumescent epoxy coating specifically designed for outdoor use by industrial facilities dealing with highly flammable products such as oil refineries and chemical plants. The coating is applied usually by spray gun to exterior structural steel conduits, pipes and valves, offshore platforms and liquefied petroleum gas tanks. Fireproofing provides two types of protection: ablation or dissipation of heat by burn-off and "intumescence" or swelling; the coating swells to about five times its original size, forming a protective blanket of char which retards transfer of heat to the metal structure preventing loss of structural strength and possible collapse which would compound the fire fighting problem.
75 FR 2481 - Sunshine Act; Notice of Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-15
... installation and commissioning of a new gas-fired industrial water heater, manufactured by Energy Systems... its investigation into a natural gas explosion that occurred at the ConAgra production facility in... consider urgent recommendations to the National Fire Protection Association (NFPA), the American Gas...
48 CFR 252.246-7004 - Safety of Facilities, Infrastructure, and Equipment for Military Operations.
Code of Federal Regulations, 2013 CFR
2013-10-01
..., Infrastructure, and Equipment for Military Operations. As prescribed in 246.270-4, use the following clause... contract comply with Unified Facilities Criteria (UFC) 1-200-01 for— (1) Fire protection; (2) Structural...
48 CFR 252.246-7004 - Safety of Facilities, Infrastructure, and Equipment for Military Operations.
Code of Federal Regulations, 2012 CFR
2012-10-01
..., Infrastructure, and Equipment for Military Operations. As prescribed in 246.270-4, use the following clause... contract comply with Unified Facilities Criteria (UFC) 1-200-01 for— (1) Fire protection; (2) Structural...
48 CFR 252.246-7004 - Safety of Facilities, Infrastructure, and Equipment for Military Operations.
Code of Federal Regulations, 2014 CFR
2014-10-01
..., Infrastructure, and Equipment for Military Operations. As prescribed in 246.270-4, use the following clause... contract comply with Unified Facilities Criteria (UFC) 1-200-01 for— (1) Fire protection; (2) Structural...
30 CFR 77.1100 - Fire protection; training and organization.
Code of Federal Regulations, 2010 CFR
2010-07-01
....1100 Section 77.1100 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF... facilities and equipment shall be provided commensurate with the potential fire hazards at each structure...
George M. Jemison
1935-01-01
The necessity of forest-fire protection is generally recognized in the United Slates. The tremendous damage done by forest fires each year to valuable timber, watershed cover, forest range, wildlife, recreational facilities, and personal property has impressed upon the people the need for preventing and controlling forest fires so far as this is humanly possible.
Applications of multi-spectral imaging: failsafe industrial flame detector
NASA Astrophysics Data System (ADS)
Wing Au, Kwong; Larsen, Christopher; Cole, Barry; Venkatesha, Sharath
2016-05-01
Industrial and petrochemical facilities present unique challenges for fire protection and safety. Typical scenarios include detection of an unintended fire in a scene, wherein the scene also includes a flare stack in the background. Maintaining a high level of process and plant safety is a critical concern. In this paper, we present a failsafe industrial flame detector which has significant performance benefits compared to current flame detectors. The design involves use of microbolometer in the MWIR and LWIR spectrum and a dual band filter. This novel flame detector can help industrial facilities to meet their plant safety and critical infrastructure protection requirements while ensuring operational and business readiness at project start-up.
Occupancy Fire Record. Libraries.
ERIC Educational Resources Information Center
National Fire Protection Association, Boston, MA.
Considerations essential to adequate protection for library facilities have been assembled in the form of recommendations and related to specific examples. Five steps are given which outline the procedures to follow in order to achieve fire safety. With regard to planning, six considerations are dealt with in detail--(1) the saving of lives, (2)…
Fire-protection research for energy technology: Fy 80 year end report
NASA Astrophysics Data System (ADS)
Hasegawa, H. K.; Alvares, N. J.; Lipska, A. E.; Ford, H.; Priante, S.; Beason, D. G.
1981-05-01
This continuing research program was initiated in order to advance fire protection strategies for Fusion Energy Experiments (FEE). The program expanded to encompass other forms of energy research. Accomplishments for fiscal year 1980 were: finalization of the fault-free analysis of the Shiva fire management system; development of a second-generation, fire-growth analysis using an alternate model and new LLNL combustion dynamics data; improvements of techniques for chemical smoke aerosol analysis; development and test of a simple method to assess the corrosive potential of smoke aerosols; development of an initial aerosol dilution system; completion of primary small-scale tests for measurements of the dynamics of cable fires; finalization of primary survey format for non-LLNL energy technology facilities; and studies of fire dynamics and aerosol production from electrical insulation and computer tape cassettes.
2013-07-18
are subject to damage and abrasion (figure 5). The use of an extension cord instead of fixed wiring creates the possibility of fire , electrical shock...Medical Clinic has an adjacent warehouse that is of a higher hazard and is not separated by 1-hour fire resistance rated construction. KMC 17-May...higher hazard and is not separated by 1-hour fire resistance rated construction. DynCorp NO Awaiting USG Decision DI has not received governmental
Code of Federal Regulations, 2011 CFR
2011-10-01
...— (1) Fire protection; (2) Structural integrity; (3) Electrical systems; (4) Plumbing; (5) Water treatment; (6) Waste disposal; and (7) Telecommunications networks. (c) Existing host nation facilities...
Code of Federal Regulations, 2013 CFR
2013-10-01
...— (1) Fire protection; (2) Structural integrity; (3) Electrical systems; (4) Plumbing; (5) Water treatment; (6) Waste disposal; and (7) Telecommunications networks. (c) Existing host nation facilities...
Code of Federal Regulations, 2014 CFR
2014-10-01
...— (1) Fire protection; (2) Structural integrity; (3) Electrical systems; (4) Plumbing; (5) Water treatment; (6) Waste disposal; and (7) Telecommunications networks. (c) Existing host nation facilities...
Code of Federal Regulations, 2012 CFR
2012-10-01
...— (1) Fire protection; (2) Structural integrity; (3) Electrical systems; (4) Plumbing; (5) Water treatment; (6) Waste disposal; and (7) Telecommunications networks. (c) Existing host nation facilities...
2005-03-25
This interim final rule with comment period adopts the substance of the April 15, 2004 temporary interim amendment (TIA) 00-1 (101), Alcohol Based Hand Rub Solutions, an amendment to the 2000 edition of the Life Safety Code, published by the National Fire Protection Association (NFPA). This amendment will allow certain health care facilities to place alcohol-based hand rub dispensers in egress corridors under specified conditions. This interim final rule with comment period also requires that nursing facilities install smoke detectors in resident rooms and public areas if they do not have a sprinkler system installed throughout the facility or a hard-wired smoke detection system in those areas.
75 FR 17644 - Update to NFPA 101, Life Safety Code, for State Home Facilities
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-07
... DEPARTMENT OF VETERANS AFFAIRS 38 CFR Part 51 RIN 2900-AN59 Update to NFPA 101, Life Safety Code... certain provisions of the 2009 edition of the National Fire Protection Association's NFPA 101, Life Safety... standards regarding life safety and fire safety. DATES: Written comments must be received by VA on or before...
36 CFR 1234.12 - What are the fire safety requirements that apply to records storage facilities?
Code of Federal Regulations, 2011 CFR
2011-07-01
... structural elements and construction assemblies must be in accordance with ASTM E 119-98 (incorporated by... necessary, they must be protected by self-closing or automatic Class A fire doors, or equivalent doors that... such areas with 4-hour rated construction assemblies. (p) Equipment rows running perpendicular to the...
Special report. Revising your fire safety plans.
1993-12-01
Every hospital has a fire safety plan, although some fail to update their plans when circumstances change, such as when the facility is refurbished or new fire protection equipment is added, or when new wings bring in additional patients and staff. Others may fail to develop new education programs to heighten staff awareness of what is expected of them during a fire and to train employees to meet those expectations. In this report, we'll examine the new fire safety plans at two Massachusetts hospitals and the revisions they made to address these issues. We'll offer suggestions for effectively evaluating and revising your own fire safety plans.
1986-01-01
by sensors in the test cell and sampled, digitized, averaged, and calibrated by the facility computer system. The data included flowrates calculated ...before the next test could be started. This required about 2 minutes. 6.4 Combat Damage Testing Appendix C contains calculations and analysis...were comparable (Figure 7-5). Agent quantities required per MIL-E-22285 were again calculated using the equations noted in paragraph 7.1.1. The
40 CFR 265.35 - Required aisle space.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 25 2010-07-01 2010-07-01 false Required aisle space. 265.35 Section... FACILITIES Preparedness and Prevention § 265.35 Required aisle space. The owner or operator must maintain aisle space to allow the unobstructed movement of personnel, fire protection equipment, spill control...
40 CFR 265.35 - Required aisle space.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 26 2011-07-01 2011-07-01 false Required aisle space. 265.35 Section... FACILITIES Preparedness and Prevention § 265.35 Required aisle space. The owner or operator must maintain aisle space to allow the unobstructed movement of personnel, fire protection equipment, spill control...
40 CFR 265.35 - Required aisle space.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 27 2012-07-01 2012-07-01 false Required aisle space. 265.35 Section... FACILITIES Preparedness and Prevention § 265.35 Required aisle space. The owner or operator must maintain aisle space to allow the unobstructed movement of personnel, fire protection equipment, spill control...
40 CFR 265.35 - Required aisle space.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 26 2014-07-01 2014-07-01 false Required aisle space. 265.35 Section... FACILITIES Preparedness and Prevention § 265.35 Required aisle space. The owner or operator must maintain aisle space to allow the unobstructed movement of personnel, fire protection equipment, spill control...
40 CFR 265.35 - Required aisle space.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 27 2013-07-01 2013-07-01 false Required aisle space. 265.35 Section... FACILITIES Preparedness and Prevention § 265.35 Required aisle space. The owner or operator must maintain aisle space to allow the unobstructed movement of personnel, fire protection equipment, spill control...
The development and evaluation of water-mist fire extinguishing systems
NASA Astrophysics Data System (ADS)
Beason, D. G.; Staggs, K. J.
1994-08-01
Fire protection for underfloor space is primarily provided by Halon 1301 which has proven to be very effective. However, due to the link between halons and the possible depletion of the stratospheric ozone layer, plans have been implemented to eventually phase out Halon 1301 and 1211. In September 1987 the Montreal Protocol concerning chlorofluorocarbons (CFC) and halons was signed by the United States, the European Economic Community, and 23 other nations. The Montreal Protocol calls for freezing halon production at 1986 levels. Because the majority of underfloor fire protection at Lawrence Livermore National Laboratory (LLNL), as well as other Department of Energy (DOE) sites, is either Halon 1301 or sprinklers, some other means of suppression will have to be developed and verified. The potential loss to facilities housing computer or control rooms damaged by underfloor fires can be extreme. These losses would not only include hardware and software replacement costs, but also lost computing and control capability. Here at LLNL technical research in a facility could be severely affected. Recent studies conducted by the Fire Research Discipline of the Special Projects Division have shown that severe fires fueled by cable insulation can develop within as little as a 6-in-high underfloor space (even with mechanical ventilation shut off). Studies also show that conventional sprinklers may not be effective in preventing this destruction. Therefore, we are investigating the water-mist fire extinguishing system as an alternative to Halon 1301 and sprinklers.
DOE Fire Protection Handbook, Volume I
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
The Department of Energy (DOE) Fire Protection Program is delineated in a number of source documents including; the Code of Federal Regulations (CFR), DOE Policy Statements and Orders, DOE and national consensus standards (such as those promulgated by the National Fire Protection Association), and supplementary guidance, This Handbook is intended to bring together in one location as much of this material as possible to facilitate understanding and ease of use. The applicability of any of these directives to individual Maintenance and Operating Contractors or to given facilities and operations is governed by existing contracts. Questions regarding applicability should be directedmore » to the DOE Authority Having Jurisdiction for fire safety. The information provided within includes copies of those DOE directives that are directly applicable to the implementation of a comprehensive fire protection program. They are delineated in the Table of Contents. The items marked with an asterisk (*) are included on the disks in WordPerfect 5.1 format, with the filename noted below. The items marked with double asterisks are provided as hard copies as well as on the disk. For those using MAC disks, the files are in Wordperfect 2.1 for MAC.« less
49 CFR 193.2905 - Protective enclosures.
Code of Federal Regulations, 2011 CFR
2011-10-01
... stations; (7) Control systems; (8) Fire control equipment; (9) Security communications systems; and (10... not be located near features outside of the facility, such as trees, poles, or buildings, which could...
General Employee Training Live, Course 15503
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gabel, Daniel Glen; Hughes, Heather
This training at Los Alamos National Laboratory contains the following sections: Introduction to the Laboratory, Institutional Quality Assurance, Facilities, Policies, Procedures, and Other Requirements, Safety Expectations, Worker Protection: Occupational Safety and Health, Industrial Hygiene and Safety, Lockout/Tagout, General Employee Radiological Training, Fire Protection, Security, Emergency Operations, Occupational Health, and Environment.
Hall-McGee, P
1997-01-01
The author provides a training package for forensic staff on how to handle prisoner patients who are being treated at a healthcare facility. She covers such topics as fire and evacuation plans, interim life safety measures, blood and bloodborne pathogens exposure, universal precautions, respiratory protection and TB, and voluntary medical immobilization and protection devices.
Navy Safety Center data on the effects of fire protection systems on electrical equipment
NASA Astrophysics Data System (ADS)
Levine, Robert S.
1991-04-01
Records of the Navy Safety Center, Norfolk, VA were reviewed to find data relevant to inadvertant operation of installed fire extinguishing systems in civilian nuclear power plants. Navy data show the incidence of collateral fire or other damage by fresh water on operating electrical equipment in submarines and in shore facilities is about the same as the civilian experience, about 30 percent. Aboard surface ships, however, the collateral damage incidence in much lower, about 15 percent. With sea water, the collateral damage incidence is at least 75 percent. It is concluded that the fire extinguisher water has to be contaminated, as by rust in sprinkler systems or deposited salt spray, for most collateral damage to occur. Reasons for inadvertant operation (or advertant operation) of firex systems at shore facilities, submarines, and surface ships resemble those for nuclear power plants. Mechanical or electrical failures lead the list, followed by mishaps during maintenance. Detector and alarm system failures are significant problems at Navy shore facilities, and significant at nuclear power plants. Fixed halon and CO2 systems in shore facilities cause no collateral damage. Lists of individual Navy incidents with water and with halon and carbon dioxide are included as appendices.
40 CFR 267.51 - What is the purpose of the contingency plan and how do I use it?
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 26 2010-07-01 2010-07-01 false What is the purpose of the contingency plan and how do I use it? 267.51 Section 267.51 Protection of Environment ENVIRONMENTAL PROTECTION... facility. You must design the plan to minimize hazards to human health or the environment from fires...
29 CFR 11.11 - Development of environmental analyses and documents.
Code of Federal Regulations, 2012 CFR
2012-07-01
..., theaters), fire and police protection, schools, energy resources, waste disposal, water, traffic and... facility to residential areas; (5) The potential impact on the quality of drinking water, air quality...
29 CFR 11.11 - Development of environmental analyses and documents.
Code of Federal Regulations, 2014 CFR
2014-07-01
..., theaters), fire and police protection, schools, energy resources, waste disposal, water, traffic and... facility to residential areas; (5) The potential impact on the quality of drinking water, air quality...
29 CFR 11.11 - Development of environmental analyses and documents.
Code of Federal Regulations, 2013 CFR
2013-07-01
..., theaters), fire and police protection, schools, energy resources, waste disposal, water, traffic and... facility to residential areas; (5) The potential impact on the quality of drinking water, air quality...
29 CFR 11.11 - Development of environmental analyses and documents.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., theaters), fire and police protection, schools, energy resources, waste disposal, water, traffic and... facility to residential areas; (5) The potential impact on the quality of drinking water, air quality...
Fire Fighter Trainer Environmental Considerations
1981-01-08
established by the Environmental Protection Agency and various state and local ordinances. At present, the Navy’s fire fighter train- ing facilities use...necessary. All operational capabilities for military communications equipment have been retained. Each training compartment has a local communications...the state or local air pollution-control agencies on a case-by-case basis. 4.2.4 Japanese Air Pollution-Control Regulations. The Japanese Air Quality
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-16
... Per Diem Program as a part of the effort to increase the useful life of the facilities of grantees... grantees are required to ensure that facilities rehabilitated under this NOFA meet the Life Safety Code of the National Fire and Protection Association. Please note, typically the Life Safety Code is more...
History of Fire Events in the U.S. Commercial Nuclear Industry
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bijan Najafi; Joglar-Biloch, Francisco; Kassawara, Robert P.
2002-07-01
Over the past decade, interest in performance-based fire protection has increased within the nuclear industry. In support of this growing interest, in 1997 the Electric Power Research Institute (EPRI) developed a long-range plan to develop/improve data and tools needed to support Risk-Informed/Performance-Based fire protection. This plan calls for continued improvement in collection and use of information obtained from fire events at nuclear plants. The data collection process has the objectives of improving the insights gained from such data and reducing the uncertainty in fire risk and fire modeling methods in order to make them a more reliable basis for performancemore » based fire protection programs. In keeping with these objectives, EPRI continues to collect, review and analyze fire events in support of the nuclear industry. EPRI collects these records in cooperation with the Nuclear Electric Insurance Limited (NEIL), by compiling public fire event reports and by direct solicitation of U.S. nuclear facilities. EPRI fire data collection project is based on the principle that the understanding of history is one of the cornerstones of improving fire protection technology and practice. Therefore, the goal has been to develop and maintain a comprehensive database of fire events with flexibility to support various aspects of fire protection engineering. With more than 1850 fire records over a period of three decades and 2400 reactor years, this is the most comprehensive database of nuclear power industry fire events in existence today. In general, the frequency of fires in the U.S. commercial nuclear industry remains constant. In few cases, e.g., transient fires and fires in BWR offgas/recombiner systems, where either increasing or decreasing trends are observed, these trends tend to slow after 1980. The key issues in improving quality of the data remain to be consistency of the recording and reporting of fire events and difficulties in collection of records. EPRI has made significant progress towards improving the quality of the fire events data through use of multiple collection methods as well as its review and verification. To date EPRI has used this data to develop a generic fire ignition frequency model for U.S. nuclear power industry (Ref. 1, 4 and 5) as well as to support other models in support of EPRI Fire Risk Methods such as a cable fire manual suppression model. EPRI will continue its effort to collect and analyze operating data to support risk informed/performance based fire safety engineering, including collection and analysis of impairment data for fire protection systems and features. This paper provides details on the collection and application of fire events to risk informed/performance based fire protection. The paper also provides valuable insights into improving both collection and use of fire events data. (authors)« less
A Tool for Rating the Resilience of Critical Infrastructures in Extreme Fires
2014-05-01
provide a tool for NRC to help the Canadian industry to develop extreme fire protection materials and technologies for critical infrastructures. Future...supported by the Canadian Safety and Security Program (CSSP) which is led by Defence Research and Development Canada’s Centre for Security Science, in...in oil refinery and chemical industry facilities. The only available standard in North America that addresses the transportation infrastructure is
10 CFR Appendix A to Part 50 - General Design Criteria for Nuclear Power Plants
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 1 2014-01-01 2014-01-01 false General Design Criteria for Nuclear Power Plants A... FACILITIES Pt. 50, App. A Appendix A to Part 50—General Design Criteria for Nuclear Power Plants Table of... Design Bases for Protection Against Natural Phenomena 2 Fire Protection 3 Environmental and Dynamic...
10 CFR Appendix A to Part 50 - General Design Criteria for Nuclear Power Plants
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 1 2013-01-01 2013-01-01 false General Design Criteria for Nuclear Power Plants A... FACILITIES Pt. 50, App. A Appendix A to Part 50—General Design Criteria for Nuclear Power Plants Table of... Design Bases for Protection Against Natural Phenomena 2 Fire Protection 3 Environmental and Dynamic...
10 CFR Appendix A to Part 50 - General Design Criteria for Nuclear Power Plants
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 1 2010-01-01 2010-01-01 false General Design Criteria for Nuclear Power Plants A... FACILITIES Pt. 50, App. A Appendix A to Part 50—General Design Criteria for Nuclear Power Plants Table of... Design Bases for Protection Against Natural Phenomena 2 Fire Protection 3 Environmental and Dynamic...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Clancy, T J; Brown, C G; Ong, M M
2006-01-11
Presented here is an innovation in lighting safety certification, and a description of its implementation for high explosives processing and storage facilities at Lawrence Livermore National Laboratory. Lightning rods have proven useful in the protection of wooden structures; however, modern structures made of rebar, concrete, and the like, require fresh thinking. Our process involves a rigorous and unique approach to lightning safety for modern buildings, where the internal voltages and currents are quantified and the risk assessed. To follow are the main technical aspects of lightning protection for modern structures and these methods comply with the requirements of the Nationalmore » Fire Protection Association, the National Electrical Code, and the Department of Energy [1][2]. At the date of this release, we have certified over 70 HE processing and storage cells at our Site 300 facility.« less
Construction safety in DOE. Part 1, Students guide
DOE Office of Scientific and Technical Information (OSTI.GOV)
Handwerk, E C
This report is the first part of a compilation of safety standards for construction activities on DOE facilities. This report covers the following areas: general safety and health provisions; occupational health and environmental control/haz mat; personal protective equipment; fire protection and prevention; signs, signals, and barricades; materials handling, storage, use, and disposal; hand and power tools; welding and cutting; electrical; and scaffolding.
The Ins and Outs of Modern Doors.
ERIC Educational Resources Information Center
College Planning & Management, 1999
1999-01-01
Discusses the qualities and trends in modern metal doors for educational facilities that include fire protection and sound-control attributes. Important differences in door manufacturing methods and materials are addressed and sound-transmission class values, ratings, and rating descriptions are listed. (GR)
After the Disaster: Restoring Library Service.
ERIC Educational Resources Information Center
Griffith, J. W.
1983-01-01
Discusses precautions which can be taken to minimize loss or damage to library buildings and collections resulting from natural disasters (fires, floods, hurricanes, earthquakes, tornadoes, storms). Preventive measures (alarm systems, interior protection), salvage efforts, restoration of collection and library facility, rebuilding collection and…
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-26
... Management for the construction, operation, and protection of a wildland fire suppression facility. The... telecommunications device for the deaf (TDD) may call the Federal Information Relay Service (FIRS) at 1-800- 877-8339...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lindsey, C. T.; Gano, K. A.; Lucas, J. G.
The 183-D Water Filtration Facility is located in the 100-D Area of the Hanford Site, north of Richland, Washington. It was used to provide filtered water for cooling the 105-D Reactor and supplying fire-protection and drinking water for all facilities in the 100-D Area. The facility has been inactive since the 1980s and is now scheduled for demolition. Therefore, an evaluation was conducted to determine if any part of the facility was being used as roosting habitat by bats.
2006-09-22
This final rule adopts the substance of the April 15, 2004 tentative interim amendment (TIA) 00-1 (101), Alcohol Based Hand Rub Solutions, an amendment to the 2000 edition of the Life Safety Code, published by the National Fire Protection Association (NFPA). This amendment allows certain health care facilities to place alcohol-based hand rub dispensers in egress corridors under specified conditions. This final rule also requires that nursing facilities at least install battery-operated single station smoke alarms in resident rooms and common areas if they are not fully sprinklered or they do not have system-based smoke detectors in those areas. Finally, this final rule confirms as final the provisions of the March 25, 2005 interim final rule with changes and responds to public comments on that rule.
Aerosol can puncture device operational test plan
DOE Office of Scientific and Technical Information (OSTI.GOV)
Leist, K.J.
1994-05-03
Puncturing of aerosol cans is performed in the Waste Receiving and Processing Facility Module 1 (WRAP 1) process as a requirement of the waste disposal acceptance criteria for both transuranic (TRU) waste and low-level waste (LLW). These cans have contained such things as paints, lubricating oils, paint removers, insecticides, and cleaning supplies which were used in radioactive facilities. Due to Westinghouse Hanford Company (WHC) Fire Protection concerns of the baseline system`s fire/explosion proof characteristics, a study was undertaken to compare the baseline system`s design to commercially available puncturing devices. While the study found no areas which might indicate a riskmore » of fire or explosion, WHC Fire Protection determined that the puncturing system must have a demonstrated record of safe operation. This could be obtained either by testing the baseline design by an independent laboratory, or by substituting a commercially available device. As a result of these efforts, the commercially available Aerosolv can puncturing device was chosen to replace the baseline design. Two concerns were raised with the system. Premature blinding of the coalescing/carbon filter, due to its proximity to the puncture and draining operation; and overpressurization of the collection bottle due to its small volume and by blinding of the filter assembly. As a result of these concerns, testing was deemed necessary. The objective of this report is to outline test procedures for the Aerosolv.« less
Code of Federal Regulations, 2010 CFR
2010-07-01
... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Smoking. 127.1601 Section 127.1601 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED... Waterfront Facilities Handling Liquefied Hazardous Gas Fire Protection § 127.1601 Smoking. Each operator of a...
Code of Federal Regulations, 2014 CFR
2014-07-01
... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false Smoking. 127.1601 Section 127.1601 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED... Waterfront Facilities Handling Liquefied Hazardous Gas Fire Protection § 127.1601 Smoking. Each operator of a...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false Smoking. 127.1601 Section 127.1601 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED... Waterfront Facilities Handling Liquefied Hazardous Gas Fire Protection § 127.1601 Smoking. Each operator of a...
Code of Federal Regulations, 2012 CFR
2012-07-01
... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false Smoking. 127.1601 Section 127.1601 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED... Waterfront Facilities Handling Liquefied Hazardous Gas Fire Protection § 127.1601 Smoking. Each operator of a...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Smoking. 127.1601 Section 127.1601 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED... Waterfront Facilities Handling Liquefied Hazardous Gas Fire Protection § 127.1601 Smoking. Each operator of a...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, B.T.
1993-03-01
This report presents the results of an oversight assessment (OA) conducted by the US Department of Energy's (DOE) Office of Environment, Safety and Health (EH) of operational readiness review (ORR) activities for the Replacement Tritium Facility (RTF) located at Savannah River Site (SRS). The EH OA of this facility took place concurrently with an ORR conducted by the DOE Office of Defense Programs (DP). The DP ORR was conducted from January 19 through February 5, 1993. The EH OA was performed in accordance with the protocol and procedures specified in EH Program for Oversight Assessment of Operational Readiness Evaluations formore » Startups and Restarts,'' dated September 15, 1992. The EH OA Team evaluated the DP ORR to determine whether it was thorough and demonstrated sufficient inquisitiveness to verify that the implementation of programs and procedures adequately ensures the protection of worker safety and health. The EH OA Team performed its evaluation of the DP ORR in the following technical areas: occupational safety, industrial hygiene, and respiratory protection; fire protection; and chemical safety. In the areas of fire protection and chemical safety, the EH OA Team conducted independent vertical-slice reviews to confirm DP ORR results. Within each technical area, the EH OA Team reviewed the DP ORR Plan, including the Criteria Review and Approach Documents (CRADs); the qualifications of individual DP ORR team members; the performance of planned DP ORR activities; and the results of the DP ORR.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, B.T.
1993-03-01
This report presents the results of an oversight assessment (OA) conducted by the US Department of Energy`s (DOE) Office of Environment, Safety and Health (EH) of operational readiness review (ORR) activities for the Replacement Tritium Facility (RTF) located at Savannah River Site (SRS). The EH OA of this facility took place concurrently with an ORR conducted by the DOE Office of Defense Programs (DP). The DP ORR was conducted from January 19 through February 5, 1993. The EH OA was performed in accordance with the protocol and procedures specified in ``EH Program for Oversight Assessment of Operational Readiness Evaluations formore » Startups and Restarts,`` dated September 15, 1992. The EH OA Team evaluated the DP ORR to determine whether it was thorough and demonstrated sufficient inquisitiveness to verify that the implementation of programs and procedures adequately ensures the protection of worker safety and health. The EH OA Team performed its evaluation of the DP ORR in the following technical areas: occupational safety, industrial hygiene, and respiratory protection; fire protection; and chemical safety. In the areas of fire protection and chemical safety, the EH OA Team conducted independent vertical-slice reviews to confirm DP ORR results. Within each technical area, the EH OA Team reviewed the DP ORR Plan, including the Criteria Review and Approach Documents (CRADs); the qualifications of individual DP ORR team members; the performance of planned DP ORR activities; and the results of the DP ORR.« less
46 CFR 176.810 - Fire protection.
Code of Federal Regulations, 2013 CFR
2013-10-01
... systems, including sensors and alarms. (b) The owner, managing operator, or a qualified servicing facility... satisfaction of the Coast Guard inspector. Dry chemical (cartridge operated) Examine pressure cartridge and... and nozzle to see if they are clear. Insert charged cartridge. Ensure dry chemical is free flowing...
46 CFR 176.810 - Fire protection.
Code of Federal Regulations, 2012 CFR
2012-10-01
... systems, including sensors and alarms. (b) The owner, managing operator, or a qualified servicing facility... satisfaction of the Coast Guard inspector. Dry chemical (cartridge operated) Examine pressure cartridge and... and nozzle to see if they are clear. Insert charged cartridge. Ensure dry chemical is free flowing...
46 CFR 176.810 - Fire protection.
Code of Federal Regulations, 2014 CFR
2014-10-01
... systems, including sensors and alarms. (b) The owner, managing operator, or a qualified servicing facility... satisfaction of the Coast Guard inspector. Dry chemical (cartridge operated) Examine pressure cartridge and... and nozzle to see if they are clear. Insert charged cartridge. Ensure dry chemical is free flowing...
Code of Federal Regulations, 2011 CFR
2011-01-01
.... Emergency lighting. Emergency lighting units with at least an 8-hour battery power supply shall be provided..., combustible and flammable gases and liquids, high efficiency particulate air and charcoal filters, dry ion...
Code of Federal Regulations, 2014 CFR
2014-01-01
.... Emergency lighting. Emergency lighting units with at least an 8-hour battery power supply shall be provided..., combustible and flammable gases and liquids, high efficiency particulate air and charcoal filters, dry ion...
Code of Federal Regulations, 2012 CFR
2012-01-01
.... Emergency lighting. Emergency lighting units with at least an 8-hour battery power supply shall be provided..., combustible and flammable gases and liquids, high efficiency particulate air and charcoal filters, dry ion...
Code of Federal Regulations, 2013 CFR
2013-01-01
.... Emergency lighting. Emergency lighting units with at least an 8-hour battery power supply shall be provided..., combustible and flammable gases and liquids, high efficiency particulate air and charcoal filters, dry ion...
Control Strategies for Zebra Mussel Infestations at Public Facilities
1992-07-01
detailed examina- tion of hard -to-reach surfaces or specific components (such as fire protection systems or intake pipes for sensor devices) should...trash racks. Trash racks could become partially clogged with zebra mussels, shells , and other debris. Flow through the openings would be reduced, and... shells to the top of the lock wall. These are now used by Ontario Hydro for removing zebra mussels. At most facilities, the culvert is totally dewatered
24 CFR 982.605 - SRO: Housing quality standards.
Code of Federal Regulations, 2013 CFR
2013-04-01
... an SRO unit without passing through any other unit. (4) Sprinkler system. A sprinkler system that protects all major spaces, hard wired smoke detectors, and such other fire and safety improvements as State... utilize an approvable public or private disposal system. (E) Sanitary facilities must be reasonably...
24 CFR 982.605 - SRO: Housing quality standards.
Code of Federal Regulations, 2012 CFR
2012-04-01
... an SRO unit without passing through any other unit. (4) Sprinkler system. A sprinkler system that protects all major spaces, hard wired smoke detectors, and such other fire and safety improvements as State... utilize an approvable public or private disposal system. (E) Sanitary facilities must be reasonably...
24 CFR 982.605 - SRO: Housing quality standards.
Code of Federal Regulations, 2014 CFR
2014-04-01
... an SRO unit without passing through any other unit. (4) Sprinkler system. A sprinkler system that protects all major spaces, hard wired smoke detectors, and such other fire and safety improvements as State... utilize an approvable public or private disposal system. (E) Sanitary facilities must be reasonably...
24 CFR 982.605 - SRO: Housing quality standards.
Code of Federal Regulations, 2011 CFR
2011-04-01
... an SRO unit without passing through any other unit. (4) Sprinkler system. A sprinkler system that protects all major spaces, hard wired smoke detectors, and such other fire and safety improvements as State... utilize an approvable public or private disposal system. (E) Sanitary facilities must be reasonably...
Research Needs for Rural Public Services.
ERIC Educational Resources Information Center
Stocker, Frederick D.
The report proposes a conceptual framework for researching key issues relating to rural public facility policy affecting such services as fire protection, water systems, roads, wastewater treatment, hospitals, and others, and identifies important research needs in this area. Major components of the framework are sources of financing (private and…
Critical Protection Item classification for a waste processing facility at Savannah River Site
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ades, M.J.; Garrett, R.J.
1993-10-01
This paper describes the methodology for Critical Protection Item (CPI) classification and its application to the Structures, Systems and Components (SSC) of a waste processing facility at the Savannah River Site (SRS). The WSRC methodology for CPI classification includes the evaluation of the radiological and non-radiological consequences resulting from postulated accidents at the waste processing facility and comparison of these consequences with allowable limits. The types of accidents considered include explosions and fire in the facility and postulated accidents due to natural phenomena, including earthquakes, tornadoes, and high velocity straight winds. The radiological analysis results indicate that CPIs are notmore » required at the waste processing facility to mitigate the consequences of radiological release. The non-radiological analysis, however, shows that the Waste Storage Tank (WST) and the dike spill containment structures around the formic acid tanks in the cold chemical feed area and waste treatment area of the facility should be identified as CPIs. Accident mitigation options are provided and discussed.« less
PBF Cooling Tower Auxiliary Building (PER624) interior. Camera facing north. ...
PBF Cooling Tower Auxiliary Building (PER-624) interior. Camera facing north. Deluge valves and automatic fire protection piping for Cooling Tower. Photographer: Holmes. Date: May 20, 1970. INEEL negative no. 70-2323 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
Science Laboratory Safety: Findings and Implications for Teacher Education.
ERIC Educational Resources Information Center
Swami, Piyush
1986-01-01
Summarizes a survey of the condition of high school science laboratories in the greater Cincinnati area (N=36). Reports safety measures undertaken for fire and burn and eye and face protection, waste disposal, storage facilities, and ventilation. Offers suggestions and plans for enriching safety education programs for teachers. (ML)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, B.
1993-03-01
This report presents the results of an oversight assessment (OA) conducted by the US Department of Energy's (DOE) Office of Environment, Safety and Health (EH) of the operational readiness review (ORR) activities for the Cold Chemical Runs (CCRs) at the Defense Waste Processing Facility (DWPF) located at Savannah River Site (SRS). The EH OA of this facility took place concurrently with an ORR performed by the DOE Office of Environmental Restoration and Waste Management (EM). The EM ORR was conducted from September 28, 1992, through October 9, 1992, although portions of the EM ORR were extended beyond this period. Themore » EH OA evaluated the comprehensiveness and effectiveness of the EM ORR. The EH OA was designed to ascertain whether the EM ORR was thorough and demonstrated sufficient inquisitiveness to verify that the implementation of programs and procedures is adequate to assure the protection of worker safety and health. The EH OA was carried out in accordance with the protocol and procedures of the EH Program for Oversight Assessment of Operational Readiness Evaluations for Startups and Restarts,'' dated September 15, 1992. Based on its OA and verification of the resolution of EH OA findings, the EH OA Team believes that the startup of the CCRs may be safely begun, pending satisfactory completion and verification of the prestart findings identified by the EM ORR. The EH OA was based primarily on an evaluation of the comprehensiveness and effectiveness of the EM ORR and addressed the following areas: industrial safety, industrial hygiene, and respiratory protection; fire protection; and chemical safety. The EH OA conducted independent vertical-slice'' reviews to confirm EM ORR results in the areas of confined-space entry, respiratory protection, fire protection, and chemical safety.« less
Southern Great Plains Safety Orientation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schatz, John
2014-05-01
Welcome to the Atmospheric Radiation Measurement (ARM) Climate Research Facility (ARM) Southern Great Plains (SGP) site. This U.S. Department of Energy (DOE) site is managed by Argonne National Laboratory (ANL). It is very important that all visitors comply with all DOE and ANL safety requirements, as well as those of the Occupational Safety and Health Administration (OSHA), the National Fire Protection Association, and the U.S. Environmental Protection Agency, and with other requirements as applicable.
Spatial-Temporal Dynamics of Urban Fire Incidents: a Case Study of Nanjing, China
NASA Astrophysics Data System (ADS)
Yao, J.; Zhang, X.
2016-06-01
Fire and rescue service is one of the fundamental public services provided by government in order to protect people, properties and environment from fires and other disasters, and thus promote a safer living environment. Well understanding spatial-temporal dynamics of fire incidents can offer insights for potential determinants of various fire events and enable better fire risk estimation, assisting future allocation of prevention resources and strategic planning of mitigation programs. Using a 12-year (2002-2013) dataset containing the urban fire events in Nanjing, China, this research explores the spatial-temporal dynamics of urban fire incidents. A range of exploratory spatial data analysis (ESDA) approaches and tools, such as spatial kernel density and co-maps, are employed to examine the spatial, temporal and spatial-temporal variations of the fire events. Particular attention has been paid to two types of fire incidents: residential properties and local facilities, due to their relatively higher occurrence frequencies. The results demonstrated that the amount of urban fire has greatly increased in the last decade and spatial-temporal distribution of fire events vary among different incident types, which implies varying impact of potential influencing factors for further investigation.
Testing of Fire Fighting Foam.
1980-11-01
for Fresh and Sea Water ( MIL - F - 24385 ); -(C) Underwriters Laboratories Inc. S andard for Air Foam Equipment and Liquid Con- centrates (UL162);4D...C. Test Facilities 6 D. Test Procedures 7 III. Results of Tests A. FRN-1007 33 B. MIL - F - 24385 34 C. UL 162 34 D. O- F -555C 35 E. Foam Quality 35 IV...1 gpm) H N-heptane in. inch (25.4 mm = 1 in.) ipm liters per minute M Motor Octane Rating MIL MIL - F - 24385 Test Method NFPA National Fire Protection
NASA Astrophysics Data System (ADS)
Sun, Ye; Li, Zhi; Wang, Jian; Zhang, Dan; Gao, Yang; Zhang, He
2018-02-01
According to the installed capacity, coal type and the kinds of environmental protection facilities of coal-fired power plants in Jilin Province in China, five typical coal-fired units were chosen. PM2.5 from final stack outlet of five typical units was gain by Dekati PM2.5(Finland). The characteristics of PM2.5 composition in flue gases discharged into the air from selected coal-fueled power plants are analyzed in this paper.
Tiger Team Assessment of the Los Alamos National Laboratory
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1991-11-01
The purpose of the safety and health assessment was to determine the effectiveness of representative safety and health programs at the Los Alamos National Laboratory (LANL). Within the safety and health programs at LANL, performance was assessed in the following technical areas: Organization and Administration, Quality Verification, Operations, Maintenance, Training and Certification, Auxiliary Systems, Emergency Preparedness, Technical Support, Packaging and Transportation, Nuclear Criticality Safety, Security/Safety Interface, Experimental Activities, Site/Facility Safety Review, Radiological Protection, Personnel Protection, Worker Safety and Health (OSHA) Compliance, Fire Protection, Aviation Safety, Explosives Safety, Natural Phenomena, and Medical Services.
Fire Safety in Nursing Facilities: Participant's Coursebook.
ERIC Educational Resources Information Center
Walker (Bonnie) and Associates, Inc., Crofton, MD.
Fewer people die in nursing facility fires than in fires occurring in other places where older people live. Fire remains, however, a significant threat in nursing facilities. This book is centered around six "modules" that present a fire safety training program for managers and staff in nursing homes. These modules present the following…
46 CFR 76.25-90 - Installations contracted for prior to September 30, 1997.
Code of Federal Regulations, 2013 CFR
2013-10-01
... VESSELS FIRE PROTECTION EQUIPMENT Automatic Sprinkling System, Details § 76.25-90 Installations contracted...) The details of the system must be in general agreement with NFPA 13 (incorporated by reference, see 46 CFR 76.01-2) insofar as is reasonable and practicable. Existing piping, pumping facilities, sprinkler...
46 CFR 76.25-90 - Installations contracted for prior to September 30, 1997.
Code of Federal Regulations, 2010 CFR
2010-10-01
... VESSELS FIRE PROTECTION EQUIPMENT Automatic Sprinkling System, Details § 76.25-90 Installations contracted...) The details of the system must be in general agreement with NFPA 13 (incorporated by reference, see 46 CFR 76.01-2) insofar as is reasonable and practicable. Existing piping, pumping facilities, sprinkler...
46 CFR 76.25-90 - Installations contracted for prior to September 30, 1997.
Code of Federal Regulations, 2011 CFR
2011-10-01
... VESSELS FIRE PROTECTION EQUIPMENT Automatic Sprinkling System, Details § 76.25-90 Installations contracted...) The details of the system must be in general agreement with NFPA 13 (incorporated by reference, see 46 CFR 76.01-2) insofar as is reasonable and practicable. Existing piping, pumping facilities, sprinkler...
46 CFR 76.25-90 - Installations contracted for prior to September 30, 1997.
Code of Federal Regulations, 2014 CFR
2014-10-01
... VESSELS FIRE PROTECTION EQUIPMENT Automatic Sprinkling System, Details § 76.25-90 Installations contracted...) The details of the system must be in general agreement with NFPA 13 (incorporated by reference, see 46 CFR 76.01-2) insofar as is reasonable and practicable. Existing piping, pumping facilities, sprinkler...
46 CFR 76.25-90 - Installations contracted for prior to September 30, 1997.
Code of Federal Regulations, 2012 CFR
2012-10-01
... VESSELS FIRE PROTECTION EQUIPMENT Automatic Sprinkling System, Details § 76.25-90 Installations contracted...) The details of the system must be in general agreement with NFPA 13 (incorporated by reference, see 46 CFR 76.01-2) insofar as is reasonable and practicable. Existing piping, pumping facilities, sprinkler...
1994-03-31
overhead water sprinklers in enclosed personnel areas not already protected by existing facility fire suppression systems. Sprinkler systems shall not...facilitate future changes and updates to remain current with the application aircraft. 3.4.4 Availabilit . The ARWA SS shall be designed and constructed to
Contamination Impact of Station Brush Fire on Cleanroom Facilities
NASA Technical Reports Server (NTRS)
Carey, Phil; Blakkolb, Brian
2010-01-01
Brush and forest fires, both naturally occurring and anthropogenic in origin, in proximity to space flight hardware processing facilities raise concerns about the threat of contamination resulting from airborne particulate and molecular components of smoke. Perceptions of the severity of the threat are possibly heightened by the high sensitivity of the human sense of smell to some components present in the smoke of burning vegetation.On August 26th, 2009, a brushfire broke out north of Pasadena, California, two miles from the Jet Propulsion Laboratory. The Station Fire destroyed over 160,000 acres, coming within a few hundred yards of JPL. Smoke concentrations on Lab were very heavy over several days. All Lab operations were halted, and measures were taken to protect personnel, critical hardware, and facilities. Evaluation of real-time cleanroom monitoring data, visualinspection of facilities, filter systems, and analysis of surface cleanliness samples revealed facility environments andhardware were minimally effected.Outside air quality easily exceeded Class Ten Million. Prefilters captured most large ash and soot; multi-stage filtration greatly minimized the impact on the HEPA/ULPA filters. Air quality in HEPA filtered spacecraft assembly cleanrooms remained within Class 10,000 specification throughout. Surface cleanliness was inimally affected, as large particles were effectively removed from the airstream, and sub-micron particles have extremely long settling rates. Approximate particulate fallout within facilities was 0.00011% area coverage/day compared to 0.00038% area coverage/day during normal operations. Deposition of condensable airborne components, as measured in real time, peaked at approximately1.0 ng/cm2/day compared to 0.05 ng/cm2/day nominal.
Contamination impact of station brush fire on cleanroom facilities
NASA Astrophysics Data System (ADS)
Carey, Philip A.; Blakkolb, Brian K.
2010-08-01
Brush and forest fires, both naturally occurring and anthropogenic in origin, in proximity to space flight hardware processing facilities raise concerns about the threat of contamination resulting from airborne particulate and molecular components of smoke. Perceptions of the severity of the threat are possibly heightened by the high sensitivity of the human sense of smell to some components present in the smoke of burning vegetation. On August 26th, 2009, a brushfire broke out north of Pasadena, California, two miles from the Jet Propulsion Laboratory. The Station Fire destroyed over 160,000 acres, coming within a few hundred yards of JPL. Smoke concentrations on Lab were very heavy over several days. All Lab operations were halted, and measures were taken to protect personnel, critical hardware, and facilities. Evaluation of real-time cleanroom monitoring data, visual inspection of facilities, filter systems, and analysis of surface cleanliness samples revealed facility environments and hardware were minimally effected. Outside air quality easily exceeded Class Ten Million. Prefilters captured most large ash and soot; multi-stage filtration greatly minimized the impact on the HEPA/ULPA filters. Air quality in HEPA filtered spacecraft assembly cleanrooms remained within Class 10,000 specification throughout. Surface cleanliness was minimally affected, as large particles were effectively removed from the airstream, and sub-micron particles have extremely long settling rates. Approximate particulate fallout within facilities was 0.00011% area coverage/day compared to 0.00038% area coverage/day during normal operations. Deposition of condensable airborne components, as measured in real time, peaked at approximately 1.0 ng/cm2/day compared to 0.05 ng/cm2/day nominal.
Fire-Resistant Reinforcement Makes Steel Structures Sturdier
NASA Technical Reports Server (NTRS)
2006-01-01
Built and designed by Avco Corporation, the Apollo heat shield was coated with an ablative material whose purpose was to burn and, thus, dissipate energy. The material charred to form a protective coating which blocked heat penetration beyond the outer surface. Avco Corporation subsequently entered into a contract with Ames Research Center to develop spinoff applications of the heat shield in the arena of fire protection, specifically for the development of fire-retardant paints and foams for aircraft. This experience led to the production of Chartek 59, manufactured by Avco Specialty Materials (a subsidiary of Avco Corporation eventually acquired by Textron, Inc.) and marketed as the world s first intumescent epoxy material. As an intumescent coating, Chartek 59 expanded in volume when exposed to heat or flames and acted as an insulating barrier. It also retained its space-age ablative properties and dissipated heat through burn-off. Further applications were discovered, and the fireproofing formulation found its way into oil refineries, chemical plants, and other industrial facilities working with highly flammable products.
Fire safety of ground-based space facilities on the spaceport ;Vostochny;
NASA Astrophysics Data System (ADS)
Artamonov, Vladimir S.; Gordienko, Denis M.; Melikhov, Anatoly S.
2017-06-01
The facilities of the spaceport ;Vostochny; and the innovative technologies for fire safety to be implemented are considered. The planned approaches and prospects for fire safety ensuring at the facilities of the spaceport ;Vostochny; are presented herein, based on the study of emergency situations having resulted in fire accidents and explosion cases at the facilities supporting space vehicles operation.
14 CFR 23.859 - Combustion heater fire protection.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Combustion heater fire protection. 23.859... Construction Fire Protection § 23.859 Combustion heater fire protection. (a) Combustion heater fire regions. The following combustion heater fire regions must be protected from fire in accordance with the...
14 CFR 23.859 - Combustion heater fire protection.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Combustion heater fire protection. 23.859... Construction Fire Protection § 23.859 Combustion heater fire protection. (a) Combustion heater fire regions. The following combustion heater fire regions must be protected from fire in accordance with the...
14 CFR 23.859 - Combustion heater fire protection.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Combustion heater fire protection. 23.859... Construction Fire Protection § 23.859 Combustion heater fire protection. (a) Combustion heater fire regions. The following combustion heater fire regions must be protected from fire in accordance with the...
14 CFR 23.859 - Combustion heater fire protection.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Combustion heater fire protection. 23.859... Construction Fire Protection § 23.859 Combustion heater fire protection. (a) Combustion heater fire regions. The following combustion heater fire regions must be protected from fire in accordance with the...
14 CFR 23.859 - Combustion heater fire protection.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Combustion heater fire protection. 23.859... Construction Fire Protection § 23.859 Combustion heater fire protection. (a) Combustion heater fire regions. The following combustion heater fire regions must be protected from fire in accordance with the...
Impacts: NIST Building and Fire Research Laboratory (technical and societal)
NASA Astrophysics Data System (ADS)
Raufaste, N. J.
1993-08-01
The Building and Fire Research Laboratory (BFRL) of the National Institute of Standards and Technology (NIST) is dedicated to the life cycle quality of constructed facilities. The report describes major effects of BFRL's program on building and fire research. Contents of the document include: structural reliability; nondestructive testing of concrete; structural failure investigations; seismic design and construction standards; rehabilitation codes and standards; alternative refrigerants research; HVAC simulation models; thermal insulation; residential equipment energy efficiency; residential plumbing standards; computer image evaluation of building materials; corrosion-protection for reinforcing steel; prediction of the service lives of building materials; quality of construction materials laboratory testing; roofing standards; simulating fires with computers; fire safety evaluation system; fire investigations; soot formation and evolution; cone calorimeter development; smoke detector standards; standard for the flammability of children's sleepwear; smoldering insulation fires; wood heating safety research; in-place testing of concrete; communication protocols for building automation and control systems; computer simulation of the properties of concrete and other porous materials; cigarette-induced furniture fires; carbon monoxide formation in enclosure fires; halon alternative fire extinguishing agents; turbulent mixing research; materials fire research; furniture flammability testing; standard for the cigarette ignition resistance of mattresses; support of navy firefighter trainer program; and using fire to clean up oil spills.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-13
... the NRC's E-Filing system does not support unlisted software, and the NRC Meta System Help Desk will... methodology and performance criteria for licensees to identify fire protection systems and features that are... System (ADAMS): You may access publicly-available documents online in the NRC Library at http://www.nrc...
46 CFR 76.23-90 - Installations contracted for prior to November 19, 1952.
Code of Federal Regulations, 2014 CFR
2014-10-01
... VESSELS FIRE PROTECTION EQUIPMENT Manual Sprinkling System, Details § 76.23-90 Installations contracted...) The details of the system shall be in general agreement with §§ 76.23-5 through 76.23-25 insofar as is reasonable and practicable. Existing piping, pumping facilities, and sprinkler heads or perforated pipes may...
46 CFR 76.23-90 - Installations contracted for prior to November 19, 1952.
Code of Federal Regulations, 2010 CFR
2010-10-01
... VESSELS FIRE PROTECTION EQUIPMENT Manual Sprinkling System, Details § 76.23-90 Installations contracted...) The details of the system shall be in general agreement with §§ 76.23-5 through 76.23-25 insofar as is reasonable and practicable. Existing piping, pumping facilities, and sprinkler heads or perforated pipes may...
46 CFR 76.23-90 - Installations contracted for prior to November 19, 1952.
Code of Federal Regulations, 2013 CFR
2013-10-01
... VESSELS FIRE PROTECTION EQUIPMENT Manual Sprinkling System, Details § 76.23-90 Installations contracted...) The details of the system shall be in general agreement with §§ 76.23-5 through 76.23-25 insofar as is reasonable and practicable. Existing piping, pumping facilities, and sprinkler heads or perforated pipes may...
46 CFR 76.23-90 - Installations contracted for prior to November 19, 1952.
Code of Federal Regulations, 2011 CFR
2011-10-01
... VESSELS FIRE PROTECTION EQUIPMENT Manual Sprinkling System, Details § 76.23-90 Installations contracted...) The details of the system shall be in general agreement with §§ 76.23-5 through 76.23-25 insofar as is reasonable and practicable. Existing piping, pumping facilities, and sprinkler heads or perforated pipes may...
46 CFR 76.23-90 - Installations contracted for prior to November 19, 1952.
Code of Federal Regulations, 2012 CFR
2012-10-01
... VESSELS FIRE PROTECTION EQUIPMENT Manual Sprinkling System, Details § 76.23-90 Installations contracted...) The details of the system shall be in general agreement with §§ 76.23-5 through 76.23-25 insofar as is reasonable and practicable. Existing piping, pumping facilities, and sprinkler heads or perforated pipes may...
40 CFR 264.52 - Content of contingency plan.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 26 2014-07-01 2014-07-01 false Content of contingency plan. 264.52... Contingency Plan and Emergency Procedures § 264.52 Content of contingency plan. (a) The contingency plan must describe the actions facility personnel must take to comply with §§ 264.51 and 264.56 in response to fires...
40 CFR 264.52 - Content of contingency plan.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 27 2013-07-01 2013-07-01 false Content of contingency plan. 264.52... Contingency Plan and Emergency Procedures § 264.52 Content of contingency plan. (a) The contingency plan must describe the actions facility personnel must take to comply with §§ 264.51 and 264.56 in response to fires...
40 CFR 264.52 - Content of contingency plan.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 26 2011-07-01 2011-07-01 false Content of contingency plan. 264.52... Contingency Plan and Emergency Procedures § 264.52 Content of contingency plan. (a) The contingency plan must describe the actions facility personnel must take to comply with §§ 264.51 and 264.56 in response to fires...
Code of Federal Regulations, 2013 CFR
2013-07-01
... the levee and to repair the damaged section. (c) Flood walls—(1) Maintenance. Periodic inspections... accelerated seepage paths; (iv) The concrete has not undergone cracking, chipping, or breaking to an extent... that no fires are being built near them; (vii) No bank caving conditions exist riverward of the wall...
Code of Federal Regulations, 2012 CFR
2012-07-01
... the levee and to repair the damaged section. (c) Flood walls—(1) Maintenance. Periodic inspections... accelerated seepage paths; (iv) The concrete has not undergone cracking, chipping, or breaking to an extent... that no fires are being built near them; (vii) No bank caving conditions exist riverward of the wall...
Code of Federal Regulations, 2014 CFR
2014-07-01
... the levee and to repair the damaged section. (c) Flood walls—(1) Maintenance. Periodic inspections... accelerated seepage paths; (iv) The concrete has not undergone cracking, chipping, or breaking to an extent... that no fires are being built near them; (vii) No bank caving conditions exist riverward of the wall...
Army Water Reuse Policy - A Decision Document
2010-06-01
Marsh enhancement Streamflow augmentation Fisheries Nonpotable urban uses Fire protection Air conditioning Toilet flushing Water features US Army Corps...policy Use of IPR from suppliers or to practice on Army facilities Impact of privatization US Army Corps of Engineers® Engineer Research and...Development Center Definitions Graywater = Greywater = Gray Water = Grey Water Blackwater Toilet , Kitchen Wastewater Reclaimed Water Wastewater Treated
46 CFR 108.489 - Helicopter fueling facilities.
Code of Federal Regulations, 2010 CFR
2010-10-01
... the rate of 6.52 liters per minute for each square meter (.16 gallons per minute for each square foot... for each square meter (.1 gallon per minute for each square foot) of area covered for five minutes. (3....87 square meters (300 square feet). (b) If the fire protection system required by § 108.487 of this...
46 CFR 108.489 - Helicopter fueling facilities.
Code of Federal Regulations, 2014 CFR
2014-10-01
... the rate of 6.52 liters per minute for each square meter (.16 gallons per minute for each square foot... for each square meter (.1 gallon per minute for each square foot) of area covered for five minutes. (3....87 square meters (300 square feet). (b) If the fire protection system required by § 108.487 of this...
46 CFR 108.489 - Helicopter fueling facilities.
Code of Federal Regulations, 2012 CFR
2012-10-01
... the rate of 6.52 liters per minute for each square meter (.16 gallons per minute for each square foot... for each square meter (.1 gallon per minute for each square foot) of area covered for five minutes. (3....87 square meters (300 square feet). (b) If the fire protection system required by § 108.487 of this...
46 CFR 108.489 - Helicopter fueling facilities.
Code of Federal Regulations, 2013 CFR
2013-10-01
... the rate of 6.52 liters per minute for each square meter (.16 gallons per minute for each square foot... for each square meter (.1 gallon per minute for each square foot) of area covered for five minutes. (3....87 square meters (300 square feet). (b) If the fire protection system required by § 108.487 of this...
46 CFR 108.489 - Helicopter fueling facilities.
Code of Federal Regulations, 2011 CFR
2011-10-01
... the rate of 6.52 liters per minute for each square meter (.16 gallons per minute for each square foot... for each square meter (.1 gallon per minute for each square foot) of area covered for five minutes. (3....87 square meters (300 square feet). (b) If the fire protection system required by § 108.487 of this...
Accidental fires in clinical laboratories.
Hoeltge, G A; Miller, A; Klein, B R; Hamlin, W B
1993-12-01
The National Fire Protection Association, Quincy, Mass, estimates that 169 fires have occurred annually in health care, medical, and chemical laboratories. On the average, there are 13 civilian injuries and $1.5 million per year in direct property damage. Most fires in which the cause or ignition source can be identified originate in malfunctioning electrical equipment (41.6%) or in the facility's electrical distribution system (14.7%). The prevalence of fire safety deficiencies was measured in the College of American Pathologists Laboratory Accreditation Program. Of the 1732 inspected laboratories, 5.5% lacked records of electrical receptacle polarity and ground checks in the preceding year. Of these inspected laboratories, 4.7% had no or incomplete documentation of electrical safety checks on laboratory instruments. There was no evidence of quarterly fire exit drills in 9% of the laboratories. Deficiencies were also found in precautionary labeling (6.8%), in periodic review of safe work practices (4.2%), in the use of safety cans (3.7%), and in venting of flammable liquid storage areas (2.8%). Fire preparedness would be improved if all clinical laboratories had smoke detectors and automatic fire-extinguishing systems. In-service training courses in fire safety should be targeted to the needs of specific service areas.
NASA Technical Reports Server (NTRS)
2004-01-01
KENNEDY SPACE CENTER, FLA. -- Astrotech Space Operations facilities near KSC, workers remove protective covers from the Mercury Surface, Space Environment, Geochemistry and Ranging (MESSENGER) spacecraft now resting on the turnover fixture. Workers will perform the propulsion system phasing test firing gas through the thrusters in order to verify that the right thrusters fire when expected as part of prelaunch testing at the site. Launch is scheduled for May 11 from Pad 17-B, Cape Canaveral Air Force Station. The spacecraft will fly past Venus three times and Mercury twice before starting a year-long orbital study of Mercury in July 2009.
Code of Federal Regulations, 2014 CFR
2014-01-01
... appropriate fire safety precautions in their work; (i) Keep facilities in the safest condition practicable... accident and fire prevention responsibilities of occupant agencies? 102-74.360 Section 102-74.360 Public... MANAGEMENT REGULATION REAL PROPERTY 74-FACILITY MANAGEMENT Facility Management Accident and Fire Prevention...
Code of Federal Regulations, 2013 CFR
2013-07-01
... appropriate fire safety precautions in their work; (i) Keep facilities in the safest condition practicable... accident and fire prevention responsibilities of occupant agencies? 102-74.360 Section 102-74.360 Public... MANAGEMENT REGULATION REAL PROPERTY 74-FACILITY MANAGEMENT Facility Management Accident and Fire Prevention...
Code of Federal Regulations, 2012 CFR
2012-01-01
... appropriate fire safety precautions in their work; (i) Keep facilities in the safest condition practicable... accident and fire prevention responsibilities of occupant agencies? 102-74.360 Section 102-74.360 Public... MANAGEMENT REGULATION REAL PROPERTY 74-FACILITY MANAGEMENT Facility Management Accident and Fire Prevention...
Seven layers of security to help protect biomedical research facilities.
Mortell, Norman
2010-04-01
In addition to risks such as theft and fire that can confront any type of business, the biomedical research community often faces additional concerns over animal rights extremists, infiltrations, data security and intellectual property rights. Given these concerns, it is not surprising that the industry gives a high priority to security. This article identifies security threats faced by biomedical research companies and shows how these threats are ranked in importance by industry stakeholders. The author then goes on to discuss seven key 'layers' of security, from the external environment to the research facility itself, and how these layers all contribute to the creation of a successfully secured facility.
33 CFR 127.601 - Fire equipment: General.
Code of Federal Regulations, 2011 CFR
2011-07-01
...) WATERFRONT FACILITIES WATERFRONT FACILITIES HANDLING LIQUEFIED NATURAL GAS AND LIQUEFIED HAZARDOUS GAS Waterfront Facilities Handling Liquefied Natural Gas Firefighting § 127.601 Fire equipment: General. (a) Fire... Laboratories, Inc., the Factory Mutual Research Corp., or the Coast Guard. ...
33 CFR 127.601 - Fire equipment: General.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) WATERFRONT FACILITIES WATERFRONT FACILITIES HANDLING LIQUEFIED NATURAL GAS AND LIQUEFIED HAZARDOUS GAS Waterfront Facilities Handling Liquefied Natural Gas Firefighting § 127.601 Fire equipment: General. (a) Fire... Laboratories, Inc., the Factory Mutual Research Corp., or the Coast Guard. ...
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
The Western Area Power Administration (Western) has established a formal environmental protection, auditing, monitoring, and planning program that has been in effect since 1978. The significant environmental projects and issues Western was involved with in 1995 are discussed in this annual site environmental report. It is written to show the nature and effectiveness of the environmental protection program. Western operates and maintains nearly 17,000 miles of transmission lines, 257 substations, and various appurtenant power facilities in fifteen central and western states. Western is also responsible for planning, construction, and operation and maintenance of additional federal transmission facilities that may bemore » authorized in the future. There is a combined total of 55 hydroelectric power generating plants in the service area. Additionally, Western markets the US entitlement from the Navajo coal-fired plant near Page, Arizona. The Department of Energy requires the preparation of an annual site environmental report. Because Western has over 400 facilities located in these states, this report addresses the environmental activities in all the facilities as one site.« less
Take immediate action to protect communities and workers.
Wilding, Roberta Chase; Lewis, Sharon E
2007-01-01
In many areas throughout America, thousands of industrial and military facilities and agricultural operations put large numbers of people at risk of serious injury or death due to accidental chemical releases, explosions, fires, and grossly inadequate occupational exposure standards. While some companies are moving toward "greener" production, many others do the minimum required by government agencies. As evidenced by the thousands of permit violations and accidental releases of hazardous chemicals, this means that facilities across the country consistently fail to meet regulations, incorporating the cost of fines and penalties into the cost of doing business and passing that cost on to consumers. Workers at such facilities and residents of the surrounding communities cannot wait for the eventual implementation and enforcement of federal environmental laws or adequate testing of the effect chemicals may have on the human population. Immediate action is needed to protect communities and workers at risk from chemical exposures that can compromise their health.
41 CFR 102-74.355 - With what accident and fire prevention standards must Federal facilities comply?
Code of Federal Regulations, 2010 CFR
2010-07-01
... MANAGEMENT REGULATION REAL PROPERTY 74-FACILITY MANAGEMENT Facility Management Accident and Fire Prevention... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false With what accident and fire prevention standards must Federal facilities comply? 102-74.355 Section 102-74.355 Public...
Hsieh, Ming-Hong; Wu, Jia-Wun; Li, Ya-Cing; Tang, Jia-Suei; Hsieh, Chun-Chien
2016-02-01
This paper will explore the fire and explosion characteristics of cornstarch powder as well as strategies for protecting the safety of people who are involved a dust fire or dust explosion. We discuss the 5 elements of dust explosions and conduct tests to analyze the fire and explosion characteristics of differently colored powders (yellow, golden yellow, pink, purple, orange and green). The results show that, while all of the tested powders were difficult to ignite, low moisture content was associated with significantly greater risks of ignition and flame spread. We found the auto-ignition temperature (AIT) of air-borne cornstarch powder to be between 385°C and 405°C, with yellow-colored cornstarch powder showing the highest AIT and pink-colored cornstarch powder showing the lowest AIT. The volume resistivity of all powder samples was approximately 108 Ω.m, indicating that they were nonconductive. Lighters and cigarettes are effective ignition sources, as their lit temperatures are higher than the AIT of cornstarch powder. In order to better protect the safety of individuals at venues where cornstarch powder is released, explosion control measures such as explosion containment facilities, vents, and explosion suppression and isolation devices should be installed. Furthermore, employees that work at these venues should be better trained in explosion prevention and control measures. We hope this article is a reminder to the public to recognize the fire and explosion characteristics of flammable powders as well as the preventive and control measures for dust explosions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, B.
1993-03-01
This report presents the results of an oversight assessment (OA) conducted by the US Department of Energy`s (DOE) Office of Environment, Safety and Health (EH) of the operational readiness review (ORR) activities for the Cold Chemical Runs (CCRs) at the Defense Waste Processing Facility (DWPF) located at Savannah River Site (SRS). The EH OA of this facility took place concurrently with an ORR performed by the DOE Office of Environmental Restoration and Waste Management (EM). The EM ORR was conducted from September 28, 1992, through October 9, 1992, although portions of the EM ORR were extended beyond this period. Themore » EH OA evaluated the comprehensiveness and effectiveness of the EM ORR. The EH OA was designed to ascertain whether the EM ORR was thorough and demonstrated sufficient inquisitiveness to verify that the implementation of programs and procedures is adequate to assure the protection of worker safety and health. The EH OA was carried out in accordance with the protocol and procedures of the ``EH Program for Oversight Assessment of Operational Readiness Evaluations for Startups and Restarts,`` dated September 15, 1992. Based on its OA and verification of the resolution of EH OA findings, the EH OA Team believes that the startup of the CCRs may be safely begun, pending satisfactory completion and verification of the prestart findings identified by the EM ORR. The EH OA was based primarily on an evaluation of the comprehensiveness and effectiveness of the EM ORR and addressed the following areas: industrial safety, industrial hygiene, and respiratory protection; fire protection; and chemical safety. The EH OA conducted independent ``vertical-slice`` reviews to confirm EM ORR results in the areas of confined-space entry, respiratory protection, fire protection, and chemical safety.« less
Factors Controlling Vegetation Fires in Protected and Non-Protected Areas of Myanmar
Biswas, Sumalika; Vadrevu, Krishna Prasad; Lwin, Zin Mar; Lasko, Kristofer; Justice, Christopher O.
2015-01-01
Fire is an important disturbance agent in Myanmar impacting several ecosystems. In this study, we quantify the factors impacting vegetation fires in protected and non-protected areas of Myanmar. Satellite datasets in conjunction with biophysical and anthropogenic factors were used in a spatial framework to map the causative factors of fires. Specifically, we used the frequency ratio method to assess the contribution of each causative factor to overall fire susceptibility at a 1km scale. Results suggested the mean fire density in non-protected areas was two times higher than the protected areas. Fire-land cover partition analysis suggested dominant fire occurrences in the savannas (protected areas) and woody savannas (non-protected areas). The five major fire causative factors in protected areas in descending order include population density, land cover, tree cover percent, travel time from nearest city and temperature. In contrast, the causative factors in non-protected areas were population density, tree cover percent, travel time from nearest city, temperature and elevation. The fire susceptibility analysis showed distinct spatial patterns with central Myanmar as a hot spot of vegetation fires. Results from propensity score matching suggested that forests within protected areas have 11% less fires than non-protected areas. Overall, our results identify important causative factors of fire useful to address broad scale fire risk concerns at a landscape scale in Myanmar. PMID:25909632
Factors controlling vegetation fires in protected and non-protected areas of myanmar.
Biswas, Sumalika; Vadrevu, Krishna Prasad; Lwin, Zin Mar; Lasko, Kristofer; Justice, Christopher O
2015-01-01
Fire is an important disturbance agent in Myanmar impacting several ecosystems. In this study, we quantify the factors impacting vegetation fires in protected and non-protected areas of Myanmar. Satellite datasets in conjunction with biophysical and anthropogenic factors were used in a spatial framework to map the causative factors of fires. Specifically, we used the frequency ratio method to assess the contribution of each causative factor to overall fire susceptibility at a 1km scale. Results suggested the mean fire density in non-protected areas was two times higher than the protected areas. Fire-land cover partition analysis suggested dominant fire occurrences in the savannas (protected areas) and woody savannas (non-protected areas). The five major fire causative factors in protected areas in descending order include population density, land cover, tree cover percent, travel time from nearest city and temperature. In contrast, the causative factors in non-protected areas were population density, tree cover percent, travel time from nearest city, temperature and elevation. The fire susceptibility analysis showed distinct spatial patterns with central Myanmar as a hot spot of vegetation fires. Results from propensity score matching suggested that forests within protected areas have 11% less fires than non-protected areas. Overall, our results identify important causative factors of fire useful to address broad scale fire risk concerns at a landscape scale in Myanmar.
29 CFR Appendix C to Subpart L of... - Fire Protection References For Further Information
Code of Federal Regulations, 2011 CFR
2011-07-01
... Protection Handbook, National Fire Protection Association, Batterymarch Park, Quincy, MA 02269. B. Accident.... Private Fire Brigades, NFPA 27; National Fire Protection Association, Batterymarch Park, Quincy, MA 02269..., Batterymarch Park, Quincy, MA 02269 . 3. Fire Fighter Professional Qualifications, NFPA 1001; National Fire...
29 CFR Appendix C to Subpart L of... - Fire Protection References For Further Information
Code of Federal Regulations, 2012 CFR
2012-07-01
... Protection Handbook, National Fire Protection Association, Batterymarch Park, Quincy, MA 02269. B. Accident.... Private Fire Brigades, NFPA 27; National Fire Protection Association, Batterymarch Park, Quincy, MA 02269..., Batterymarch Park, Quincy, MA 02269 . 3. Fire Fighter Professional Qualifications, NFPA 1001; National Fire...
29 CFR Appendix C to Subpart L of... - Fire Protection References For Further Information
Code of Federal Regulations, 2013 CFR
2013-07-01
... Protection Handbook, National Fire Protection Association, Batterymarch Park, Quincy, MA 02269. B. Accident.... Private Fire Brigades, NFPA 27; National Fire Protection Association, Batterymarch Park, Quincy, MA 02269..., Batterymarch Park, Quincy, MA 02269 . 3. Fire Fighter Professional Qualifications, NFPA 1001; National Fire...
2013-09-30
fire sprinkler system during the initial construction of the RSOI facilities. The construction contract to build the RSOI...International Building Code. Compliant manual and automatic fire alarm and notification systems , portable fire extinguishers, fire sprinkler systems ...automatic fire sprinkler system that was not operational, a fire department connection that was obstructed, and a fire detection system
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-11
... Nuclear Power Plant Fire Protection (CARMEN-FIRE) AGENCY: Nuclear Regulatory Commission. ACTION: Draft..., ``Compensatory and Alternative Regulatory Measures for Nuclear Power Plant Fire Protection (CARMEN-FIRE).'' In... integral part of NRC-approved fire protection programs. However, compensatory measures are not expected to...
14 CFR 23.863 - Flammable fluid fire protection.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Flammable fluid fire protection. 23.863... Construction Fire Protection § 23.863 Flammable fluid fire protection. (a) In each area where flammable fluids... protective devices. (4) Means available for controlling or extinguishing a fire, such as stopping flow of...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Irving, J.S.
DOE prepared an environmental assessment (EA)for wildland fire management activities on the Idaho National Engineering and Environmental Laboratory (INEEL) (DOE/EA-1372). The EA was developed to evaluate wildland fire management options for pre-fire, fire suppression, and post fire activities. Those activities have an important role in minimizing the conversion of the native sagebrush steppe ecosystem found on the INEEL to non-native weeds. Four alternative management approaches were analyzed: Alternative 1 - maximum fire protection; Alternative 2 - balanced fire protection; Alternative 2 - balanced fire protection; Alternative 3 - protect infrastructure and personnel; and Alternative 4 - no action/traditional fire protection.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Irving, John S
DOE prepared an environmental assessment (EA)for wildland fire management activities on the Idaho National Engineering and Environmental Laboratory (INEEL) (DOE/EA-1372). The EA was developed to evaluate wildland fire management options for pre-fire, fire suppression, and post fire activities. Those activities have an important role in minimizing the conversion of the native sagebrush steppe ecosystem found on the INEEL to non-native weeds. Four alternative management approaches were analyzed: Alternative 1 - maximum fire protection; Alternative 2 - balanced fire protection; Alternative 2 - balanced fire protection; Alternative 3 - protect infrastructure and personnel; and Alternative 4 - no action/traditional fire protection.
Primer on spontaneous heating and pyrophoricity
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1994-12-01
This primer was prepared as an information resource for personnel responsible for operation of DOE nuclear facilities. It has sections on combustion principles, spontaneous heating/ignition of hydrocarbons and organics, pyrophoric gases and liquids, pyrophoric nonmetallic solids, pyrophoric metals (including Pu and U), and accident case studies. Although the information in this primer is not all-encompassing, it should provide the reader with a fundamental knowledge level sufficient to recognize most spontaneous combustion hazards and how to prevent ignition and widespread fires. This primer is provided as an information resource only, and is not intended to replace any fire protection or hazardousmore » material training.« less
49 CFR 193.2801 - Fire protection.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 3 2010-10-01 2010-10-01 false Fire protection. 193.2801 Section 193.2801...: FEDERAL SAFETY STANDARDS Fire Protection § 193.2801 Fire protection. Each operator must provide and maintain fire protection at LNG plants according to sections 9.1 through 9.7 and section 9.9 of NFPA 59A...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-23
... Equipment, Training and Drills Onboard Offshore Facilities and Mobile Offshore Drilling Units (MODUs... lifesaving and fire-fighting equipment, training and drills on board offshore facilities and MODUs operating... guidance concerning lifesaving and fire-fighting equipment, training, and drills onboard manned offshore...
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1995-04-01
The US Department of Energy (DOE) proposes to construct and maintain additional storage capacity at Oak Ridge National Laboratory (ORNL), Oak Ridge, Tennessee, for liquid low-level radioactive waste (LLLW). New capacity would be provided by a facility partitioned into six individual tank vaults containing one 100,000 gallon LLLW storage tank each. The storage tanks would be located within the existing Melton Valley Storage Tank (MVST) facility. This action would require the extension of a potable water line approximately one mile from the High Flux Isotope Reactor (HFIR) area to the proposed site to provide the necessary potable water for themore » facility including fire protection. Alternatives considered include no-action, cease generation, storage at other ORR storage facilities, source treatment, pretreatment, and storage at other DOE facilities.« less
29 CFR 1926.150 - Fire protection.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 29 Labor 8 2010-07-01 2010-07-01 false Fire protection. 1926.150 Section 1926.150 Labor... (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Fire Protection and Prevention § 1926.150 Fire protection. (a) General requirements. (1) The employer shall be responsible for the development of a fire...
40 CFR 60.40 - Applicability and designation of affected facility.
Code of Federal Regulations, 2014 CFR
2014-07-01
... for Fossil-Fuel-Fired Steam Generators § 60.40 Applicability and designation of affected facility. (a) The affected facilities to which the provisions of this subpart apply are: (1) Each fossil-fuel-fired... per hour (MMBtu/hr)). (2) Each fossil-fuel and wood-residue-fired steam generating unit capable of...
40 CFR 60.40 - Applicability and designation of affected facility.
Code of Federal Regulations, 2013 CFR
2013-07-01
... for Fossil-Fuel-Fired Steam Generators § 60.40 Applicability and designation of affected facility. (a) The affected facilities to which the provisions of this subpart apply are: (1) Each fossil-fuel-fired... per hour (MMBtu/hr)). (2) Each fossil-fuel and wood-residue-fired steam generating unit capable of...
40 CFR 60.40 - Applicability and designation of affected facility.
Code of Federal Regulations, 2012 CFR
2012-07-01
... for Fossil-Fuel-Fired Steam Generators § 60.40 Applicability and designation of affected facility. (a) The affected facilities to which the provisions of this subpart apply are: (1) Each fossil-fuel-fired... per hour (MMBtu/hr)). (2) Each fossil-fuel and wood-residue-fired steam generating unit capable of...
Passive fire building protection system evaluation (case study: millennium ict centre)
NASA Astrophysics Data System (ADS)
Rahman, Vinky; Stephanie
2018-03-01
Passive fire protection system is a system that refers to the building design, both regarding of architecture and structure. This system usually consists of structural protection that protects the structure of the building and prevents the spread of fire and facilitate the evacuation process in case of fire. Millennium ICT Center is the largest electronic shopping center in Medan, Indonesia. As a public building that accommodates the crowd, this building needs a fire protection system by the standards. Therefore, the purpose of this study is to evaluate passive fire protection system of Millennium ICT Center building. The study was conducted to describe the facts of the building as well as direct observation to the research location. The collected data is then processed using the AHP (Analytical Hierarchy Process) method in its weighting process to obtain the reliability value of passive fire protection fire system. The results showed that there are some components of passive fire protection system in the building, but some are still unqualified. The first section in your paper
29 CFR 1915.507 - Land-side fire protection systems.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 29 Labor 7 2013-07-01 2013-07-01 false Land-side fire protection systems. 1915.507 Section 1915... Protection in Shipyard Employment § 1915.507 Land-side fire protection systems. (a) Employer responsibilities. The employer must ensure all fixed and portable fire protection systems needed to meet an OSHA...
29 CFR 1915.507 - Land-side fire protection systems.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 29 Labor 7 2012-07-01 2012-07-01 false Land-side fire protection systems. 1915.507 Section 1915... Protection in Shipyard Employment § 1915.507 Land-side fire protection systems. (a) Employer responsibilities. The employer must ensure all fixed and portable fire protection systems needed to meet an OSHA...
29 CFR 1915.507 - Land-side fire protection systems.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 29 Labor 7 2011-07-01 2011-07-01 false Land-side fire protection systems. 1915.507 Section 1915... Protection in Shipyard Employment § 1915.507 Land-side fire protection systems. (a) Employer responsibilities. The employer must ensure all fixed and portable fire protection systems needed to meet an OSHA...
29 CFR 1915.507 - Land-side fire protection systems.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 29 Labor 7 2014-07-01 2014-07-01 false Land-side fire protection systems. 1915.507 Section 1915... Protection in Shipyard Employment § 1915.507 Land-side fire protection systems. (a) Employer responsibilities. The employer must ensure all fixed and portable fire protection systems needed to meet an OSHA...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-29
... Nuclear Power Plant Fire Protection (CARMEN-FIRE) AGENCY: Nuclear Regulatory Commission. ACTION: Notice of... Nuclear Power Plant Fire Protection (CARMEN-FIRE), Draft Report for Comment.'' DATES: Comments on this... CONTACT: Felix Gonzalez, Fire Research Branch, Division of Risk Analysis, Office of Nuclear Regulatory...
Risks, designs, and research for fire safety in spacecraft
NASA Technical Reports Server (NTRS)
Friedman, Robert; Sacksteder, Kurt R.; Urban, David
1991-01-01
Current fire protection for spacecraft relies mainly on fire prevention through the use of nonflammable materials and strict storage controls of other materials. The Shuttle also has smoke detectors and fire extinguishers, using technology similar to aircraft practices. While experience has shown that the current fire protection is adequate, future improvements in fire safety technology to meet the challenges of long duration space missions, such as the Space Station Freedom, are essential. All spacecraft fire protection systems, however, must deal with the unusual combustion characteristics and operational problems in the low gravity environment. The features of low gravity combustion that affect spacecraft fire safety, and the issues in fire protection for Freedom that must be addressed eventually to provide effective and conservative fire protection systems are discussed.
Fire safety knowledge and practices among residents of an assisted living facility.
Jaslow, David; Ufberg, Jacob; Yoon, Russell; McQueen, Clay; Zecher, Derek; Jakubowski, Greg
2005-01-01
Assisted living facilities (ALFs) pose unique fire risks to the elderly that may be linked to specific fire safety (FS) practices. To evaluate self-reported FS practices among ALF residents. All residents of a small ALF were surveyed regarding actual and hypothetical FS behaviors, self-perceived fire risk, and FS preparedness. Fifty-eight ALF residents completed the survey. Thirty-three (58%) individuals reported one or more disabilities. Seven (12%) residents ignored the fire alarm and 21 (35%) could not hear it clearly. Sixteen (28%) residents would attempt to locate the source of a fire rather than escape from the building. Only 24 (42%) residents were familiar with the building fire plan. Twenty-three (40%) people surveyed believed that they were not at risk of fire in the study facility. Residents of an ALF may be at increased fire injury risk due to their FS practices and disabilities.
School Fire Protection: Contents Count
ERIC Educational Resources Information Center
American School and University, 1976
1976-01-01
The heart of a fire protection system is the sprinkler system. National Fire Protection Association (NFPA) statistics show that automatic sprinklers dramatically reduce fire damage and loss of life. (Author)
Code of Federal Regulations, 2011 CFR
2011-01-01
... accident and fire prevention responsibilities of occupant agencies? 102-74.360 Section 102-74.360 Public... MANAGEMENT REGULATION REAL PROPERTY 74-FACILITY MANAGEMENT Facility Management Accident and Fire Prevention § 102-74.360 What are the specific accident and fire prevention responsibilities of occupant agencies...
Manual for Public School Facilities: Fire Prevention and Fire Inspection.
ERIC Educational Resources Information Center
New York State Education Dept., Albany. Bureau of Educational Management Services.
This manual is designed for use by New York public school administrators and facility inspectors, providing instruction for completing the state's Fire Safety Report. It provides background information and details about the State Fire Prevention and Building Code and regulations, and explains the inspection and enforcement processes. One-third of…
76 FR 40777 - Interim Enforcement Policy for Certain Fire Protection Issues
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-12
... Certain Fire Protection Issues AGENCY: Nuclear Regulatory Commission. ACTION: Policy statement; revision... Enforcement Policy on enforcement discretion for certain fire protection issues to extend the enforcement... policy affects licensees that are transitioning to use the National Fire Protection Association Standard...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Palmer, E.
1997-04-01
This report documents the Resource Conservation and Recovery Act (RCRA) Facility Investigation/Remedial Investigation/Baseline Risk Assessment (RFI/RI/BRA) for the Fire Department Hose Training Facility (FDTF) (904-113G).
Fire-danger rating in the future.
James E. Hefner
1967-01-01
The forest resources of this country must be protected from wildfire. Protection does not eliminate fire but does reduce loss from fire. In recent years, more acres have been burned on the unprotected 3 percent of forest land than on the 97 percent under organized fire protection. Protection from fire has saved more than 100 million acres per year. This figure is based...
14 CFR 25.859 - Combustion heater fire protection.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Combustion heater fire protection. 25.859....859 Combustion heater fire protection. (a) Combustion heater fire zones. The following combustion... surrounds the combustion chamber. However, no fire extinguishment is required in cabin ventilating air...
14 CFR 25.859 - Combustion heater fire protection.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Combustion heater fire protection. 25.859....859 Combustion heater fire protection. (a) Combustion heater fire zones. The following combustion... surrounds the combustion chamber. However, no fire extinguishment is required in cabin ventilating air...
14 CFR 25.859 - Combustion heater fire protection.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Combustion heater fire protection. 25.859....859 Combustion heater fire protection. (a) Combustion heater fire zones. The following combustion... surrounds the combustion chamber. However, no fire extinguishment is required in cabin ventilating air...
14 CFR 25.859 - Combustion heater fire protection.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Combustion heater fire protection. 25.859....859 Combustion heater fire protection. (a) Combustion heater fire zones. The following combustion... surrounds the combustion chamber. However, no fire extinguishment is required in cabin ventilating air...
14 CFR 25.859 - Combustion heater fire protection.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Combustion heater fire protection. 25.859....859 Combustion heater fire protection. (a) Combustion heater fire zones. The following combustion... surrounds the combustion chamber. However, no fire extinguishment is required in cabin ventilating air...
Cost-benefit analysis of passive fire protections in road LPG transportation.
Paltrinieri, Nicola; Bonvicini, Sarah; Spadoni, Gigliola; Cozzani, Valerio
2012-02-01
The cost-benefit evaluation of passive fire protection adoption in the road transport of liquefied petroleum gas (LPG) was investigated. In a previous study, mathematical simulations of real scale fire scenarios proved the effectiveness of passive fire protections in preventing the "fired" boiling liquid expanding vapor explosion (BLEVE), thus providing a significant risk reduction. In the present study the economical aspects of the adoption of fire protections are analyzed and an approach to cost-benefit analysis (CBA) is proposed. The CBA model is based on the comparison of the risk reduction due to fire protections (expressed in monetary terms by the value of a statistical life) and the cost of the application of fire protections to a fleet of tankers. Different types of fire protections were considered, as well as the possibility to apply protections to the entire fleet or only to a part of it. The application of the proposed model to a real-life case study is presented and discussed. Results demonstrate that the adoption of passive fire protections on road tankers, though not compulsory in Europe, can be economically feasible, thus representing a concrete measure to achieve control of the "major hazard accidents" cited by the European legislation. © 2011 Society for Risk Analysis.
46 CFR 72.05-40 - Insulation, other than for structural fire protection.
Code of Federal Regulations, 2012 CFR
2012-10-01
... VESSELS CONSTRUCTION AND ARRANGEMENT Structural Fire Protection § 72.05-40 Insulation, other than for structural fire protection. (a) Any insulation installed for heat and comfort, refrigeration (including air... 46 Shipping 3 2012-10-01 2012-10-01 false Insulation, other than for structural fire protection...
46 CFR 72.05-40 - Insulation, other than for structural fire protection.
Code of Federal Regulations, 2010 CFR
2010-10-01
... VESSELS CONSTRUCTION AND ARRANGEMENT Structural Fire Protection § 72.05-40 Insulation, other than for structural fire protection. (a) Any insulation installed for heat and comfort, refrigeration (including air... 46 Shipping 3 2010-10-01 2010-10-01 false Insulation, other than for structural fire protection...
46 CFR 72.05-40 - Insulation, other than for structural fire protection.
Code of Federal Regulations, 2014 CFR
2014-10-01
... VESSELS CONSTRUCTION AND ARRANGEMENT Structural Fire Protection § 72.05-40 Insulation, other than for structural fire protection. (a) Any insulation installed for heat and comfort, refrigeration (including air... 46 Shipping 3 2014-10-01 2014-10-01 false Insulation, other than for structural fire protection...
46 CFR 72.05-40 - Insulation, other than for structural fire protection.
Code of Federal Regulations, 2011 CFR
2011-10-01
... VESSELS CONSTRUCTION AND ARRANGEMENT Structural Fire Protection § 72.05-40 Insulation, other than for structural fire protection. (a) Any insulation installed for heat and comfort, refrigeration (including air... 46 Shipping 3 2011-10-01 2011-10-01 false Insulation, other than for structural fire protection...
46 CFR 72.05-40 - Insulation, other than for structural fire protection.
Code of Federal Regulations, 2013 CFR
2013-10-01
... VESSELS CONSTRUCTION AND ARRANGEMENT Structural Fire Protection § 72.05-40 Insulation, other than for structural fire protection. (a) Any insulation installed for heat and comfort, refrigeration (including air... 46 Shipping 3 2013-10-01 2013-10-01 false Insulation, other than for structural fire protection...
41 CFR 102-80.135 - Who is a qualified fire protection engineer?
Code of Federal Regulations, 2010 CFR
2010-07-01
... protection engineer? 102-80.135 Section 102-80.135 Public Contracts and Property Management Federal Property... qualified fire protection engineer? A qualified fire protection engineer is defined as an individual with a thorough knowledge and understanding of the principles of physics and chemistry governing fire growth...
14 CFR 23.863 - Flammable fluid fire protection.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Flammable fluid fire protection. 23.863... Construction Fire Protection § 23.863 Flammable fluid fire protection. (a) In each area where flammable fluids... fluids, shutting down equipment, fireproof containment, or use of extinguishing agents. (5) Ability of...
14 CFR 23.863 - Flammable fluid fire protection.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Flammable fluid fire protection. 23.863... Construction Fire Protection § 23.863 Flammable fluid fire protection. (a) In each area where flammable fluids... fluids, shutting down equipment, fireproof containment, or use of extinguishing agents. (5) Ability of...
14 CFR 23.863 - Flammable fluid fire protection.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Flammable fluid fire protection. 23.863... Construction Fire Protection § 23.863 Flammable fluid fire protection. (a) In each area where flammable fluids... fluids, shutting down equipment, fireproof containment, or use of extinguishing agents. (5) Ability of...
14 CFR 23.863 - Flammable fluid fire protection.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Flammable fluid fire protection. 23.863... Construction Fire Protection § 23.863 Flammable fluid fire protection. (a) In each area where flammable fluids... fluids, shutting down equipment, fireproof containment, or use of extinguishing agents. (5) Ability of...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-14
... DEPARTMENT OF COMMERCE National Institute of Standards and Technology National Fire Protection... (NIST) is publishing this notice on behalf of the National Fire Protection Association (NFPA) to..., (301) 975-4019. SUPPLEMENTARY INFORMATION: Since 1896, the National Fire Protection Association (NFPA...
46 CFR 176.810 - Fire protection.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 7 2010-10-01 2010-10-01 false Fire protection. 176.810 Section 176.810 Shipping COAST...) INSPECTION AND CERTIFICATION Material Inspections § 176.810 Fire protection. (a) At each initial and... and have the vessel ready for inspection of its fire protection equipment, including the following: (1...
46 CFR 194.20-7 - Fire protection.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 7 2010-10-01 2010-10-01 false Fire protection. 194.20-7 Section 194.20-7 Shipping... Fire protection. (a) Each chemical storeroom shall be protected by a fixed automatic carbon dioxide... fire extinguishers are required in accordance with Table 193.50-10(a) of this subchapter. ...
[Hospital under fire--take home message from one war].
Shasha, Shaul M
2010-07-01
Future conflicts in our region will no longer be limited to clashes between opposing armies. Unlike past wars, which by and large did not target places of worship and hospitals, such structures will not be immune from attack in the "total wars" of the future, nor will the civilian population be spared. Hospitals may be hit by enemy fire and must, therefore, be ready to work under adverse conditions and emergency situations. This article describes the accumulated experience of our hospital as a confrontation Line medical facility for over 30 years, sustaining direct hits with injuries to people and damage to buildings. Lessons from those confrontations, particularly the second Lebanon war, are discussed and recommendations to other hospitals formulated, essentially highlighting the following: The need to protect the hospital's physical structures in order to guarantee the safety of patients, staff and visitors in the event of conventionaL or non-conventional war. The provision of protected transportation for the staff and in-hospitaL day-camps and dormitories for their children in order to bolster the presence of the staff on board and enable them to work unperturbed. Preparation of the hospital for work under fire, drafting emergency procedures that are custom-tailored to the needs of the hospital, particularly the evacuation of patients from vulnerable wards to protected areas, and drilling the entire staff regularly and methodically.
2011-02-18
CAPE CANAVERAL, Fla. – Deputy Fire Chief Rick Anderson, left, Chief of Fire Training George Hoggard, and Assistant Chief of Fire Training David Seymour with NASA Kennedy Space Center Protective Services participated in the "National 9/11 Flag" stitching ceremony in the Debus Conference Facility at the Kennedy Space Center Visitor Complex in Florida. The contributions of NASA, Kennedy Space Center and the state of Florida were stitched into the fabric of the American Flag, which was recovered near ground zero following the World Trade Center attacks on Sept. 11, 2001. The "New York Says Thank You Foundation" is taking the flag on a cross-country journey to be restored to its original 13-stripe design using pieces of fabric from American flags destined for retirement in all 50 states. Once the flag is restored, it will become a permanent collection of the National September 11 Memorial Museum being built at the World Trade Center site. Photo credit: NASA/Kim Shiflett
Fire Protection in Educational Occupancies.
ERIC Educational Resources Information Center
Gervais, Romeo P.
2000-01-01
Discusses the origins of school fires and the components of the fire protection code called the Life Safety Code (LSC). Three of the following LSC requirements are described: means of egress; protection from hazards; and fire suppression and alarm systems. Information on who starts fires is highlighted along with preventive measures. (GR)
14 CFR 33.17 - Fire protection.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fire protection. 33.17 Section 33.17... STANDARDS: AIRCRAFT ENGINES Design and Construction; General § 33.17 Fire protection. (a) The design and... fire during normal operation and failure conditions, and must minimize the effect of such a fire. In...
DOE Office of Scientific and Technical Information (OSTI.GOV)
De-Cheng, Chen; Chung-Kung, Lo; Tsu-Jen, Lin
2004-07-01
The living fire probabilistic risk assessment (PRA) models for all three operating nuclear power plants (NPPs) in Taiwan had been established in December 2000. In that study, a scenario-based PRA approach was adopted to systematically evaluate the fire and smoke hazards and associated risks. Using these fire PRA models developed, a risk-informed application project had also been completed in December 2002 for the evaluation of cable-tray fire-barrier wrapping exemption. This paper presents a new application of the fire PRA models to fire protection issues using the fire protection significance determination process (FP SDP). The fire protection issues studied may involvemore » the selection of appropriate compensatory measures during the period when an automatic fire detection or suppression system in a safety-related fire zone becomes inoperable. The compensatory measure can either be a 24-hour fire watch or an hourly fire patrol. The living fire PRA models were used to estimate the increase in risk associated with the fire protection issue in terms of changes in core damage frequency (CDF) and large early release frequency (LERF). In compliance with SDP at-power and the acceptance guidelines specified in RG 1.174, the fire protection issues in question can be grouped into four categories; red, yellow, white and green, in accordance with the guidelines developed for FD SDP. A 24-hour fire watch is suggested only required for the yellow condition, while an hourly fire patrol may be adopted for the white condition. More limiting requirement is suggested for the red condition, but no special consideration is needed for the green condition. For the calculation of risk measures, risk impacts from any additional fire scenarios that may have been introduced, as well as more severe initiating events and fire damages that may accompany the fire protection issue should be considered carefully. Examples are presented in this paper to illustrate the evaluation process. (authors)« less
14 CFR 25.865 - Fire protection of flight controls, engine mounts, and other flight structure.
Code of Federal Regulations, 2011 CFR
2011-01-01
... Design and Construction Fire Protection § 25.865 Fire protection of flight controls, engine mounts, and other flight structure. Essential flight controls, engine mounts, and other flight structures located in... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Fire protection of flight controls, engine...
14 CFR 25.865 - Fire protection of flight controls, engine mounts, and other flight structure.
Code of Federal Regulations, 2012 CFR
2012-01-01
... Design and Construction Fire Protection § 25.865 Fire protection of flight controls, engine mounts, and other flight structure. Essential flight controls, engine mounts, and other flight structures located in... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Fire protection of flight controls, engine...
14 CFR 25.865 - Fire protection of flight controls, engine mounts, and other flight structure.
Code of Federal Regulations, 2010 CFR
2010-01-01
... Design and Construction Fire Protection § 25.865 Fire protection of flight controls, engine mounts, and other flight structure. Essential flight controls, engine mounts, and other flight structures located in... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fire protection of flight controls, engine...
14 CFR 25.865 - Fire protection of flight controls, engine mounts, and other flight structure.
Code of Federal Regulations, 2014 CFR
2014-01-01
... Design and Construction Fire Protection § 25.865 Fire protection of flight controls, engine mounts, and other flight structure. Essential flight controls, engine mounts, and other flight structures located in... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Fire protection of flight controls, engine...
14 CFR 25.865 - Fire protection of flight controls, engine mounts, and other flight structure.
Code of Federal Regulations, 2013 CFR
2013-01-01
... Design and Construction Fire Protection § 25.865 Fire protection of flight controls, engine mounts, and other flight structure. Essential flight controls, engine mounts, and other flight structures located in... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Fire protection of flight controls, engine...
14 CFR 29.1359 - Electrical system fire and smoke protection.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Electrical system fire and smoke protection... Equipment § 29.1359 Electrical system fire and smoke protection. (a) Components of the electrical system must meet the applicable fire and smoke protection provisions of §§ 29.831 and 29.863. (b) Electrical...
14 CFR 29.1359 - Electrical system fire and smoke protection.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Electrical system fire and smoke protection... Equipment § 29.1359 Electrical system fire and smoke protection. (a) Components of the electrical system must meet the applicable fire and smoke protection provisions of §§ 29.831 and 29.863. (b) Electrical...
14 CFR 29.1359 - Electrical system fire and smoke protection.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Electrical system fire and smoke protection... Equipment § 29.1359 Electrical system fire and smoke protection. (a) Components of the electrical system must meet the applicable fire and smoke protection provisions of §§ 29.831 and 29.863. (b) Electrical...
14 CFR 29.1359 - Electrical system fire and smoke protection.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Electrical system fire and smoke protection... Equipment § 29.1359 Electrical system fire and smoke protection. (a) Components of the electrical system must meet the applicable fire and smoke protection provisions of §§ 29.831 and 29.863. (b) Electrical...
14 CFR 23.1359 - Electrical system fire protection.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Electrical system fire protection. 23.1359... Electrical Systems and Equipment § 23.1359 Electrical system fire protection. (a) Each component of the electrical system must meet the applicable fire protection requirements of §§ 23.863 and 23.1182. (b...
14 CFR 23.1359 - Electrical system fire protection.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Electrical system fire protection. 23.1359... Electrical Systems and Equipment § 23.1359 Electrical system fire protection. (a) Each component of the electrical system must meet the applicable fire protection requirements of §§ 23.863 and 23.1182. (b...
14 CFR 23.1359 - Electrical system fire protection.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Electrical system fire protection. 23.1359... Electrical Systems and Equipment § 23.1359 Electrical system fire protection. (a) Each component of the electrical system must meet the applicable fire protection requirements of §§ 23.863 and 23.1182. (b...
14 CFR 23.1359 - Electrical system fire protection.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Electrical system fire protection. 23.1359... Electrical Systems and Equipment § 23.1359 Electrical system fire protection. (a) Each component of the electrical system must meet the applicable fire protection requirements of §§ 23.863 and 23.1182. (b...
14 CFR 23.1359 - Electrical system fire protection.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Electrical system fire protection. 23.1359... Electrical Systems and Equipment § 23.1359 Electrical system fire protection. (a) Each component of the electrical system must meet the applicable fire protection requirements of §§ 23.863 and 23.1182. (b...
Basis for Interim Operation for Fuel Supply Shutdown Facility
DOE Office of Scientific and Technical Information (OSTI.GOV)
BENECKE, M.W.
2003-02-03
This document establishes the Basis for Interim Operation (BIO) for the Fuel Supply Shutdown Facility (FSS) as managed by the 300 Area Deactivation Project (300 ADP) organization in accordance with the requirements of the Project Hanford Management Contract procedure (PHMC) HNF-PRO-700, ''Safety Analysis and Technical Safety Requirements''. A hazard classification (Benecke 2003a) has been prepared for the facility in accordance with DOE-STD-1027-92 resulting in the assignment of Hazard Category 3 for FSS Facility buildings that store N Reactor fuel materials (303-B, 3712, and 3716). All others are designated Industrial buildings. It is concluded that the risks associated with the currentmore » and planned operational mode of the FSS Facility (uranium storage, uranium repackaging and shipment, cleanup, and transition activities, etc.) are acceptable. The potential radiological dose and toxicological consequences for a range of credible uranium storage building have been analyzed using Hanford accepted methods. Risk Class designations are summarized for representative events in Table 1.6-1. Mitigation was not considered for any event except the random fire event that exceeds predicted consequences based on existing source and combustible loading because of an inadvertent increase in combustible loading. For that event, a housekeeping program to manage transient combustibles is credited to reduce the probability. An additional administrative control is established to protect assumptions regarding source term by limiting inventories of fuel and combustible materials. Another is established to maintain the criticality safety program. Additional defense-in-depth controls are established to perform fire protection system testing, inspection, and maintenance to ensure predicted availability of those systems, and to maintain the radiological control program. It is also concluded that because an accidental nuclear criticality is not credible based on the low uranium enrichment, the form of the uranium, and the required controls, a Criticality Alarm System (CAS) is not required as allowed by DOE Order 420.1 (DOE 2000).« less
ERIC Educational Resources Information Center
Ohio State Univ., Columbus. National Center for Research in Vocational Education.
This military-developed text contains the first three blocks of a five-block course for use in training fire protection specialists. Covered in the individual volumes are the following topics: fire protection objectives and responsibilities (fire protection and occupational safety, extinguishing agents, principles and theory of combustion, natural…
Forest Fire Occurrence in Southern Counties, 1966-1975
M.L. Doolittle
1977-01-01
Forest fire occurrence data for individual protection units generally are unavailable outside particular state organization. Number of fires, area protected and fire occurrence rate (fires per 1,000,000 acres) from 1966 to 1975, are presented in tables for the 993 counties under protection in 13 southern states. These data are compared with data for the preceeding...
Nano-silica as the go material on heat resistant tunnel lining
NASA Astrophysics Data System (ADS)
Omar, Faizah; Osman, S. A.; Mutalib, A.
2018-04-01
This paper is concerned with passive fire protection method of protective concrete mix that is made up of fly ash, polypropylene fibre, and nano-silica. Nano-silica is focused on as the innovative material to be used in the composition of the protective concrete mix. The previous experimental studies which analyse the performance of passive fire protection on tunnels are discussed. This paper also discusses passive fire protection. The fire protection materials and behaviour analyses of tunnel structure are also presented. At the end of the paper, the recommendation of the optimum composition concrete material with fly ash, polypropylene fibre and nano-silica as tunnel lining fire protective materials is proposed.
41 CFR 301-11.11 - How do I select lodging and make lodging reservations?
Code of Federal Regulations, 2012 CFR
2012-07-01
... always stay in a “fire safe” facility. This is a facility that meets the fire safety requirements of the Hotel and Motel Fire Safety Act of 1990 (the Act), as amended (see 5 U.S.C. 5707a). (c) When selecting a...
41 CFR 301-11.11 - How do I select lodging and make lodging reservations?
Code of Federal Regulations, 2013 CFR
2013-07-01
... always stay in a “fire safe” facility. This is a facility that meets the fire safety requirements of the Hotel and Motel Fire Safety Act of 1990 (the Act), as amended (see 5 U.S.C. 5707a). (c) When selecting a...
41 CFR 301-11.11 - How do I select lodging and make lodging reservations?
Code of Federal Regulations, 2014 CFR
2014-07-01
... always stay in a “fire safe” facility. This is a facility that meets the fire safety requirements of the Hotel and Motel Fire Safety Act of 1990 (the Act), as amended (see 5 U.S.C. 5707a). (c) When selecting a...
29 CFR Appendix A to Subpart L of... - Fire Protection
Code of Federal Regulations, 2010 CFR
2010-07-01
... the International Fire Service Training Association, the National Fire Protection Association (NFPA-1041), the International Society of Fire Service Instructors and other fire training sources be... planning, and safety practices. It is again suggested that fire service training sources be consulted for...
SETS. Set Equation Transformation System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Worrell, R.B.
1992-01-13
SETS is used for symbolic manipulation of Boolean equations, particularly the reduction of equations by the application of Boolean identities. It is a flexible and efficient tool for performing probabilistic risk analysis (PRA), vital area analysis, and common cause analysis. The equation manipulation capabilities of SETS can also be used to analyze noncoherent fault trees and determine prime implicants of Boolean functions, to verify circuit design implementation, to determine minimum cost fire protection requirements for nuclear reactor plants, to obtain solutions to combinatorial optimization problems with Boolean constraints, and to determine the susceptibility of a facility to unauthorized access throughmore » nullification of sensors in its protection system.« less
78 FR 58967 - Airworthiness Directives; ATR-GIE Avions de Transport Régional Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-25
... extinction and allow fire propagation out of the nacelle fire protected area, resulting in damage to the... efficiency, delay the fire extinction and allow fire propagation out of the nacelle fire protected area... the decrease of the fire extinguishing agent efficiency, which could delay fire extinction and allow...
J. Keith Gilless; Jeremy S. Fried
1998-01-01
A fire behavior module was developed for the California Fire Economics Simulator version 2 (CFES2), a stochastic simulation model of initial attack on wildland fire used by the California Department of Forestry and Fire Protection. Fire rate of spread (ROS) and fire dispatch level (FDL) for simulated fires "occurring" on the same day are determined by making...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-19
... for OMB Review; Comment Request; Fire Protection in Shipyard Employment ACTION: Notice. SUMMARY: The... information collection request (ICR) titled, ``Fire Protection in Shipyard Employment,'' to the Office of... Fire Protection in Shipyard Employment Standard makes it mandatory for a covered employer to develop a...
14 CFR 29.859 - Combustion heater fire protection.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Combustion heater fire protection. 29.859... § 29.859 Combustion heater fire protection. (a) Combustion heater fire zones. The following combustion... any ventilating air passage that— (i) Surrounds the combustion chamber; and (ii) Would not contain...
14 CFR 29.859 - Combustion heater fire protection.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Combustion heater fire protection. 29.859... § 29.859 Combustion heater fire protection. (a) Combustion heater fire zones. The following combustion... any ventilating air passage that— (i) Surrounds the combustion chamber; and (ii) Would not contain...
14 CFR 29.859 - Combustion heater fire protection.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Combustion heater fire protection. 29.859... § 29.859 Combustion heater fire protection. (a) Combustion heater fire zones. The following combustion... any ventilating air passage that— (i) Surrounds the combustion chamber; and (ii) Would not contain...
14 CFR 29.859 - Combustion heater fire protection.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Combustion heater fire protection. 29.859... § 29.859 Combustion heater fire protection. (a) Combustion heater fire zones. The following combustion... any ventilating air passage that— (i) Surrounds the combustion chamber; and (ii) Would not contain...
14 CFR 29.859 - Combustion heater fire protection.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Combustion heater fire protection. 29.859... § 29.859 Combustion heater fire protection. (a) Combustion heater fire zones. The following combustion... any ventilating air passage that— (i) Surrounds the combustion chamber; and (ii) Would not contain...
46 CFR 161.002-1 - Incorporation by reference.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Amendments to SOLAS 74), 1992—161.002-4(b). National Fire Protection Association (NFPA) National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02269. NFPA 72, National Fire Alarm Code, 1993—161...: SPECIFICATIONS AND APPROVAL ELECTRICAL EQUIPMENT Fire-Protective Systems § 161.002-1 Incorporation by reference...
46 CFR 161.002-1 - Incorporation by reference.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Amendments to SOLAS 74), 1992—161.002-4(b). National Fire Protection Association (NFPA) National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02269. NFPA 72, National Fire Alarm Code, 1993—161...: SPECIFICATIONS AND APPROVAL ELECTRICAL EQUIPMENT Fire-Protective Systems § 161.002-1 Incorporation by reference...
49 CFR 193.2717 - Training: fire protection.
Code of Federal Regulations, 2013 CFR
2013-10-01
... under § 193.2801. (b) A written plan of continuing instruction, including plant fire drills, must be... 49 Transportation 3 2013-10-01 2013-10-01 false Training: fire protection. 193.2717 Section 193...: fire protection. (a) All personnel involved in maintenance and operations of an LNG plant, including...
49 CFR 193.2717 - Training: fire protection.
Code of Federal Regulations, 2011 CFR
2011-10-01
... under § 193.2801. (b) A written plan of continuing instruction, including plant fire drills, must be... 49 Transportation 3 2011-10-01 2011-10-01 false Training: fire protection. 193.2717 Section 193...: fire protection. (a) All personnel involved in maintenance and operations of an LNG plant, including...
49 CFR 193.2717 - Training: fire protection.
Code of Federal Regulations, 2012 CFR
2012-10-01
... under § 193.2801. (b) A written plan of continuing instruction, including plant fire drills, must be... 49 Transportation 3 2012-10-01 2012-10-01 false Training: fire protection. 193.2717 Section 193...: fire protection. (a) All personnel involved in maintenance and operations of an LNG plant, including...
49 CFR 193.2717 - Training: fire protection.
Code of Federal Regulations, 2014 CFR
2014-10-01
... under § 193.2801. (b) A written plan of continuing instruction, including plant fire drills, must be... 49 Transportation 3 2014-10-01 2014-10-01 false Training: fire protection. 193.2717 Section 193...: fire protection. (a) All personnel involved in maintenance and operations of an LNG plant, including...
48 CFR 2052.235-71 - Safety, health, and fire protection.
Code of Federal Regulations, 2014 CFR
2014-10-01
....235-71 Safety, health, and fire protection. As prescribed in 2035.70(a)(2), the contracting officer... 48 Federal Acquisition Regulations System 6 2014-10-01 2014-10-01 false Safety, health, and fire..., Health, and Fire Protection (JAN 1993) The contractor shall take all reasonable precautions in the...
48 CFR 2052.235-71 - Safety, health, and fire protection.
Code of Federal Regulations, 2012 CFR
2012-10-01
....235-71 Safety, health, and fire protection. As prescribed in 2035.70(a)(2), the contracting officer... 48 Federal Acquisition Regulations System 6 2012-10-01 2012-10-01 false Safety, health, and fire..., Health, and Fire Protection (JAN 1993) The contractor shall take all reasonable precautions in the...
48 CFR 2052.235-71 - Safety, health, and fire protection.
Code of Federal Regulations, 2013 CFR
2013-10-01
....235-71 Safety, health, and fire protection. As prescribed in 2035.70(a)(2), the contracting officer... 48 Federal Acquisition Regulations System 6 2013-10-01 2013-10-01 false Safety, health, and fire..., Health, and Fire Protection (JAN 1993) The contractor shall take all reasonable precautions in the...
48 CFR 2052.235-71 - Safety, health, and fire protection.
Code of Federal Regulations, 2011 CFR
2011-10-01
....235-71 Safety, health, and fire protection. As prescribed in 2035.70(a)(2), the contracting officer... 48 Federal Acquisition Regulations System 6 2011-10-01 2011-10-01 false Safety, health, and fire..., Health, and Fire Protection (JAN 1993) The contractor shall take all reasonable precautions in the...
Fire protection for a Martian colony
NASA Astrophysics Data System (ADS)
Beattie, Robert M., Jr.
The fire prevention failures that occurred in Apollo 1 and Challenger accidents are reviewed and used to discuss fire protection measures that should be taken in a Martian colony. Fire detection systems, classes of fire, and suppression agents are described. The organization of fire fighting personnel appropriate for Mars is addressed.
Fires in P-3 Aircraft Oxygen Systems
NASA Technical Reports Server (NTRS)
Stoltzfus, Joel
2006-01-01
Fires in three P3 aircraft oxygen systems have occurred: one in the Royal Australian Air Force (RAAF) in 1984 and two in the U.S. Navy in 1998 and 2003. All three fires started in the aluminum manifold and check valve (MCV) assembly and produced similar damages to the aircraft in which they occurred. This paper discusses a failure analysis conducted by the NASA Johnson Space Center White Sands Test Facility (WSTF) Oxygen Hazards and Testing Team on the 2003 U.S. Navy VP62 fire. It was surmised that the fire started due to heat generated by an oxygen leak past a silicone check valve seal or possibly because of particle impact near the seat of one of the MCV assembly check valves. An additional analysis of fires in several check valve poppet seals from other aircraft is discussed. These burned poppet seals came from P3 oxygen systems that had been serviced at the Naval Air Station (NAS) in Jacksonville following standard fill procedures. It was concluded that these seal fires occurred due to the heat from compression heating, particle impact, or the heat generated by an oxygen leak past the silicone check valve seal. The fact that catastrophic fires did not occur in the case of each check valve seal fire was attributed to the protective nature of the aluminum oxide layer on the check valve poppets. To prevent future fires of this nature, the U.S. and Canadian fleets of P3 aircraft have been retrofitted with MCV assemblies with an upgraded design and more burn-resistant materials.
Fire Protection for Rural Communities.
ERIC Educational Resources Information Center
Hagevig, William A.
Fire protection in rural Alaskan communities depends on individual home fire prevention and protection rather than on the services offered by a centralized fire department. Even when help is summoned to extinguish a blaze, aid does not come in the form of a cadre of highly trained firefighters; it comes instead from whomever happens to be in the…
76 FR 70414 - National Fire Protection Association (NFPA) Proposes To Revise Codes and Standards
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-14
... DEPARTMENT OF COMMERCE National Institute of Standards and Technology National Fire Protection... publishing this notice on behalf of the National Fire Protection Association (NFPA) to announce the NFPA's proposal to revise some of its fire safety codes and standards and requests proposals from the public to...
14 CFR 23.1451 - Fire protection for oxygen equipment.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Fire protection for oxygen equipment. 23... Equipment Miscellaneous Equipment § 23.1451 Fire protection for oxygen equipment. Oxygen equipment and lines... in, or escape from, any designated fire zone. (c) Be installed so that escaping oxygen cannot come in...
14 CFR 23.1451 - Fire protection for oxygen equipment.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Fire protection for oxygen equipment. 23... Equipment Miscellaneous Equipment § 23.1451 Fire protection for oxygen equipment. Oxygen equipment and lines... in, or escape from, any designated fire zone. (c) Be installed so that escaping oxygen cannot come in...
14 CFR 23.1451 - Fire protection for oxygen equipment.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Fire protection for oxygen equipment. 23... Equipment Miscellaneous Equipment § 23.1451 Fire protection for oxygen equipment. Oxygen equipment and lines... in, or escape from, any designated fire zone. (c) Be installed so that escaping oxygen cannot come in...
14 CFR 23.1451 - Fire protection for oxygen equipment.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fire protection for oxygen equipment. 23... Equipment Miscellaneous Equipment § 23.1451 Fire protection for oxygen equipment. Oxygen equipment and lines... in, or escape from, any designated fire zone. (c) Be installed so that escaping oxygen cannot come in...
14 CFR 23.1451 - Fire protection for oxygen equipment.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Fire protection for oxygen equipment. 23... Equipment Miscellaneous Equipment § 23.1451 Fire protection for oxygen equipment. Oxygen equipment and lines... in, or escape from, any designated fire zone. (c) Be installed so that escaping oxygen cannot come in...
10 CFR 36.27 - Fire protection.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 1 2010-01-01 2010-01-01 false Fire protection. 36.27 Section 36.27 Energy NUCLEAR... Requirements for Irradiators § 36.27 Fire protection. (a) The radiation room at a panoramic irradiator must... become fully shielded if a fire is detected. (b) The radiation room at a panoramic irradiator must be...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false What are the structural fire...: DESIGN, CONSTRUCTION, AND EQUIPMENT Design and Equipment Structural Fire Protection § 149.641 What are the structural fire protection requirements for accommodation spaces and modules? (a) Accommodation...
Code of Federal Regulations, 2014 CFR
2014-07-01
... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false What are the structural fire...: DESIGN, CONSTRUCTION, AND EQUIPMENT Design and Equipment Structural Fire Protection § 149.641 What are the structural fire protection requirements for accommodation spaces and modules? (a) Accommodation...
Khakzad, Nima; Landucci, Gabriele; Reniers, Genserik
2017-09-01
In the present study, we have introduced a methodology based on graph theory and multicriteria decision analysis for cost-effective fire protection of chemical plants subject to fire-induced domino effects. By modeling domino effects in chemical plants as a directed graph, the graph centrality measures such as out-closeness and betweenness scores can be used to identify the installations playing a key role in initiating and propagating potential domino effects. It is demonstrated that active fire protection of installations with the highest out-closeness score and passive fire protection of installations with the highest betweenness score are the most effective strategies for reducing the vulnerability of chemical plants to fire-induced domino effects. We have employed a dynamic graph analysis to investigate the impact of both the availability and the degradation of fire protection measures over time on the vulnerability of chemical plants. The results obtained from the graph analysis can further be prioritized using multicriteria decision analysis techniques such as the method of reference point to find the most cost-effective fire protection strategy. © 2016 Society for Risk Analysis.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Can the water supply for the... § 149.419 Can the water supply for the helicopter deck fire protection system be part of a fire water system? (a) The water supply for the helicopter deck fire protection system required under § 149.420 or...
Protecting the Library and Its Resources. A Guide to Physical Protection and Insurance.
ERIC Educational Resources Information Center
Johnson, Edward M., Ed.
The first part of this manual contains information about providing physical protection for libraries and is organized into the following chapters--(1) types of physical losses, (2) the prevention of losses, (3) fire defense measures, (4) fire protection equipment, and (5) fire protection in library planning. The second part is concerned with…
46 CFR 181.320 - Fire hoses and nozzles.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 7 2014-10-01 2014-10-01 false Fire hoses and nozzles. 181.320 Section 181.320 Shipping...) FIRE PROTECTION EQUIPMENT Fire Main System § 181.320 Fire hoses and nozzles. (a) A fire hose with a... cargo decks, where no protection is provided, hoses may be temporarily removed during heavy weather or...
46 CFR 181.320 - Fire hoses and nozzles.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 7 2013-10-01 2013-10-01 false Fire hoses and nozzles. 181.320 Section 181.320 Shipping...) FIRE PROTECTION EQUIPMENT Fire Main System § 181.320 Fire hoses and nozzles. (a) A fire hose with a... cargo decks, where no protection is provided, hoses may be temporarily removed during heavy weather or...
46 CFR 181.320 - Fire hoses and nozzles.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 7 2012-10-01 2012-10-01 false Fire hoses and nozzles. 181.320 Section 181.320 Shipping...) FIRE PROTECTION EQUIPMENT Fire Main System § 181.320 Fire hoses and nozzles. (a) A fire hose with a... cargo decks, where no protection is provided, hoses may be temporarily removed during heavy weather or...
46 CFR 181.320 - Fire hoses and nozzles.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 7 2011-10-01 2011-10-01 false Fire hoses and nozzles. 181.320 Section 181.320 Shipping...) FIRE PROTECTION EQUIPMENT Fire Main System § 181.320 Fire hoses and nozzles. (a) A fire hose with a... cargo decks, where no protection is provided, hoses may be temporarily removed during heavy weather or...
41 CFR 102-80.135 - Who is a qualified fire protection engineer?
Code of Federal Regulations, 2012 CFR
2012-01-01
... protection engineer? 102-80.135 Section 102-80.135 Public Contracts and Property Management Federal Property... qualified fire protection engineer? A qualified fire protection engineer is defined as an individual with a..., spread, and suppression, meeting one of the following criteria: (a) An engineer having an undergraduate...
41 CFR 102-80.135 - Who is a qualified fire protection engineer?
Code of Federal Regulations, 2013 CFR
2013-07-01
... protection engineer? 102-80.135 Section 102-80.135 Public Contracts and Property Management Federal Property... qualified fire protection engineer? A qualified fire protection engineer is defined as an individual with a..., spread, and suppression, meeting one of the following criteria: (a) An engineer having an undergraduate...
41 CFR 102-80.135 - Who is a qualified fire protection engineer?
Code of Federal Regulations, 2011 CFR
2011-01-01
... protection engineer? 102-80.135 Section 102-80.135 Public Contracts and Property Management Federal Property... qualified fire protection engineer? A qualified fire protection engineer is defined as an individual with a..., spread, and suppression, meeting one of the following criteria: (a) An engineer having an undergraduate...
41 CFR 102-80.135 - Who is a qualified fire protection engineer?
Code of Federal Regulations, 2014 CFR
2014-01-01
... protection engineer? 102-80.135 Section 102-80.135 Public Contracts and Property Management Federal Property... qualified fire protection engineer? A qualified fire protection engineer is defined as an individual with a..., spread, and suppression, meeting one of the following criteria: (a) An engineer having an undergraduate...
46 CFR 28.155 - Excess fire detection and protection equipment.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 1 2010-10-01 2010-10-01 false Excess fire detection and protection equipment. 28.155... protection equipment. Installation of fire detection and protection equipment in excess of that required by the regulations in this subchapter is permitted provided that the excess equipment does not endanger...
29 CFR 1915.507 - Land-side fire protection systems.
Code of Federal Regulations, 2010 CFR
2010-07-01
... specific recommendations in NFPA 14-2003 Standard for the Installation of Standpipe and Hose Systems... 29 Labor 7 2010-07-01 2010-07-01 false Land-side fire protection systems. 1915.507 Section 1915... Protection in Shipyard Employment § 1915.507 Land-side fire protection systems. (a) Employer responsibilities...
ERIC Educational Resources Information Center
Moore, Pam
2007-01-01
Fire protection is one of the most important considerations in the construction and operation of industrial plants and commercial buildings. Fire insurance rates are determined by fire probability factors, such as the type of construction, ease of transporting personnel, and the quality and quantity of fire protection equipment available. Because…
77 FR 49830 - Notice of Lodging of Proposed Amendment to the Consent Decree Under the Clean Air Act
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-17
... control particulate matter emissions at its Huntingdon, Pennsylvania facility (``the Huntingdon facility'') by either shutting down coal-fired boilers, installing air emission controls on the existing unit, or converting the coal-fired boilers to natural gas-fired boilers by June 30, 2012. The Commonwealth did not...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 17 2013-07-01 2013-07-01 false Optional NOX Emissions Estimation Protocol for Gas-Fired Peaking Units and Oil-Fired Peaking Units E Appendix E to Part 75 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTINUOUS EMISSION...
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 17 2014-07-01 2014-07-01 false Optional NOX Emissions Estimation Protocol for Gas-Fired Peaking Units and Oil-Fired Peaking Units E Appendix E to Part 75 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTINUOUS EMISSION...
Code of Federal Regulations, 2012 CFR
2012-07-01
... national consensus standard, as that term is defined in 29 CFR 1910.2, for the structural fire protection... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false What are the structural fire...: DESIGN, CONSTRUCTION, AND EQUIPMENT Design and Equipment Structural Fire Protection § 149.641 What are...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tom Elicson; Bentley Harwood; Jim Bouchard
Over a 12 month period, a fire PRA was developed for a DOE facility using the NUREG/CR-6850 EPRI/NRC fire PRA methodology. The fire PRA modeling included calculation of fire severity factors (SFs) and fire non-suppression probabilities (PNS) for each safe shutdown (SSD) component considered in the fire PRA model. The SFs were developed by performing detailed fire modeling through a combination of CFAST fire zone model calculations and Latin Hypercube Sampling (LHS). Component damage times and automatic fire suppression system actuation times calculated in the CFAST LHS analyses were then input to a time-dependent model of fire non-suppression probability. Themore » fire non-suppression probability model is based on the modeling approach outlined in NUREG/CR-6850 and is supplemented with plant specific data. This paper presents the methodology used in the DOE facility fire PRA for modeling fire-induced SSD component failures and includes discussions of modeling techniques for: • Development of time-dependent fire heat release rate profiles (required as input to CFAST), • Calculation of fire severity factors based on CFAST detailed fire modeling, and • Calculation of fire non-suppression probabilities.« less
... motels Expand sub-navigation Hotel fire safety tips Marijuana grow & extraction facilities Nightclubs and other assembly occupancies ... Fire behavior research Fire loss and injury research Benefits of home fire sprinklers Expand sub-navigation Environmental ...
Halon 1301 management planning guidance
NASA Astrophysics Data System (ADS)
1995-05-01
This ETL provides guidance to help the Base Civil Engineer (BCE) and other users manage inventories of Halon 1301, an ozone depleting substance used in many facility fire protection systems. This guidance will allow Halon 1301 users to develop the transition plans necessary to implement the DOD and Air Force policies on ozone depleting substances. Attachment 3 to this ETL contains detailed instructions on how to develop a Base Halon 1 301 Management Plan and comply with Air Force policies and regulations designed to minimize dependency on Halon 1301.
Plume Particle Collection and Sizing from Static Firing of Solid Rocket Motors
NASA Technical Reports Server (NTRS)
Sambamurthi, Jay K.
1995-01-01
Thermal radiation from the plume of any solid rocket motor, containing aluminum as one of the propellant ingredients, is mainly from the microscopic, hot aluminum oxide particles in the plume. The plume radiation to the base components of the flight vehicle is primarily determined by the plume flowfield properties, the size distribution of the plume particles, and their optical properties. The optimum design of a vehicle base thermal protection system is dependent on the ability to accurately predict this intense thermal radiation using validated theoretical models. This article describes a successful effort to collect reasonably clean plume particle samples from the static firing of the flight simulation motor (FSM-4) on March 10, 1994 at the T-24 test bed at the Thiokol space operations facility as well as three 18.3% scaled MNASA motors tested at NASA/MSFC. Prior attempts to collect plume particles from the full-scale motor firings have been unsuccessful due to the extremely hostile thermal and acoustic environment in the vicinity of the motor nozzle.
Recommendations related to Browns Ferry Fire
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1976-02-01
Based on its review of the events transpiring before, during and after the Browns Ferry fire, the Review Group concludes that the probability of disruptive fires of the magnitude of the Browns Ferry event is small, and that there is no need to restrict operation of nuclear power plants for public safety. However, it is clear that much can and should be done to reduce even further the likelihood of disabling fires and to improve assurance of rapid extinguishment of fires that occur. Consideration should be given also to features that would increase further the ability of nuclear facilities tomore » withstand large fires without loss of important functions should such fires occur. The Review Group believes that improvements, especially in the areas of fire prevention and fire control, can and should be made in most existing facilities.« less
14 CFR 27.861 - Fire protection of structure, controls, and other parts.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fire protection of structure, controls, and... Protection § 27.861 Fire protection of structure, controls, and other parts. Each part of the structure, controls, rotor mechanism, and other parts essential to a controlled landing that would be affected by...
14 CFR 27.861 - Fire protection of structure, controls, and other parts.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Fire protection of structure, controls, and... Protection § 27.861 Fire protection of structure, controls, and other parts. Each part of the structure, controls, rotor mechanism, and other parts essential to a controlled landing that would be affected by...
14 CFR 29.861 - Fire protection of structure, controls, and other parts.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fire protection of structure, controls, and... Protection § 29.861 Fire protection of structure, controls, and other parts. Each part of the structure, controls, and the rotor mechanism, and other parts essential to controlled landing and (for category A...
14 CFR 29.861 - Fire protection of structure, controls, and other parts.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Fire protection of structure, controls, and... Protection § 29.861 Fire protection of structure, controls, and other parts. Each part of the structure, controls, and the rotor mechanism, and other parts essential to controlled landing and (for category A...
Code of Federal Regulations, 2014 CFR
2014-01-01
... similar employees involved in fire protection research or in the design and development of fire protection... Protection and Prevention series, including any qualified firefighter who is assigned to perform support... considerations; (ii) Employees in positions properly classified in other series, such as Forestry Technician, for...
Code of Federal Regulations, 2010 CFR
2010-01-01
... similar employees involved in fire protection research or in the design and development of fire protection... Protection and Prevention series, including any qualified firefighter who is assigned to perform support... considerations; (ii) Employees in positions properly classified in other series, such as Forestry Technician, for...
Code of Federal Regulations, 2012 CFR
2012-01-01
... similar employees involved in fire protection research or in the design and development of fire protection... Protection and Prevention series, including any qualified firefighter who is assigned to perform support... considerations; (ii) Employees in positions properly classified in other series, such as Forestry Technician, for...
New Technology for the Fire Attire
NASA Technical Reports Server (NTRS)
1982-01-01
Although little can be done to reduce the risks of firefighting, something can be done to curb the injuries and fatalities. This is the goal of Project FIRES, a program jointly sponsored by NASA and the Federal Emergency Management Agency's U.S. Fire Administration with technical management provided by Marshall Space Flight Center. Project FIRES (Firefighter's Integrated Response Equipment System) involves applications of advanced materials and design concepts, derived from Apollo to update existing gear which does not adequately protect against many of the hazards encountered in fire suppression activities. A major focus of the effort involves application to the FIRES ensemble of lightweight, fire-resistant, heat-protective materials originally developed for use in astronauts' space suits or in spacecraft components which require thermal protection. Data from the fourteen municipal fire departments participating in the field evaluation will form a basis for development of new nationwide protective ensemble students.
Emergency Response Capability Baseline Needs Assessment - Requirements Document
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sharry, John A.
This document was prepared by John A. Sharry, LLNL Fire Marshal and LLNL Division Leader for Fire Protection and reviewed by LLNL Emergency Management Department Head James Colson. The document follows and expands upon the format and contents of the DOE Model Fire Protection Baseline Capabilities Assessment document contained on the DOE Fire Protection Web Site, but only addresses emergency response.
DEVELOPMENT OF ALTERNATIVE, NON-HALOGEN FIRE PROTECTION SYSTEM
With the phaseout of halon production, two alternative technologies - water misting and low-residue particulates - have come to the fire protection forefront. These technologies use water or dry chemicals in reduced quantities to provide acceptable fire protection. A review and a...
Code of Federal Regulations, 2011 CFR
2011-01-01
... 41 Public Contracts and Property Management 3 2011-01-01 2011-01-01 false Is the Fire Administration Authorization Act of 1992 (Public Law 102-522) relevant to fire protection engineering? 102-80.90... Authorization Act of 1992 (Public Law 102-522) relevant to fire protection engineering? Yes, the Fire...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false Is the Fire Administration Authorization Act of 1992 (Public Law 102-522) relevant to fire protection engineering? 102-80.90... Authorization Act of 1992 (Public Law 102-522) relevant to fire protection engineering? Yes, the Fire...
Code of Federal Regulations, 2012 CFR
2012-01-01
... 41 Public Contracts and Property Management 3 2012-01-01 2012-01-01 false Is the Fire Administration Authorization Act of 1992 (Public Law 102-522) relevant to fire protection engineering? 102-80.90... Authorization Act of 1992 (Public Law 102-522) relevant to fire protection engineering? Yes, the Fire...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 41 Public Contracts and Property Management 3 2013-07-01 2013-07-01 false Is the Fire Administration Authorization Act of 1992 (Public Law 102-522) relevant to fire protection engineering? 102-80.90... Authorization Act of 1992 (Public Law 102-522) relevant to fire protection engineering? Yes, the Fire...
Code of Federal Regulations, 2014 CFR
2014-01-01
... 41 Public Contracts and Property Management 3 2014-01-01 2014-01-01 false Is the Fire Administration Authorization Act of 1992 (Public Law 102-522) relevant to fire protection engineering? 102-80.90... Authorization Act of 1992 (Public Law 102-522) relevant to fire protection engineering? Yes, the Fire...
Nolte, Christoph; Agrawal, Arun
2013-02-01
Management-effectiveness scores are used widely by donors and implementers of conservation projects to prioritize, track, and evaluate investments in protected areas. However, there is little evidence that these scores actually reflect the capacity of protected areas to deliver conservation outcomes. We examined the relation between indicators of management effectiveness in protected areas and the effectiveness of protected areas in reducing fire occurrence in the Amazon rainforest. We used data collected with the Management Effectiveness Tracking Tool (METT) scorecard, adopted by some of the world's largest conservation organizations to track management characteristics believed to be crucial for protected-area effectiveness. We used the occurrence of forest fires from 2000 through 2010 as a measure of the effect of protected areas on undesired land-cover change in the Amazon basin. We used matching to compare the estimated effect of protected areas with low versus high METT scores on fire occurrence. We also estimated effects of individual protected areas on fire occurrence and explored the relation between these effects and METT scores. The relations between METT scores and effects of protected areas on fire occurrence were weak. Protected areas with higher METT scores in 2005 did not seem to have performed better than protected areas with lower METT scores at reducing fire occurrence over the last 10 years. Further research into the relations between management-effectiveness indicators and conservation outcomes in protected areas seems necessary, and our results show that the careful application of matching methods can be a suitable method for that purpose. ©2012 Society for Conservation Biology.
An atmosphere protection subsystem in the thermal power station automated process control system
NASA Astrophysics Data System (ADS)
Parchevskii, V. M.; Kislov, E. A.
2014-03-01
Matters concerned with development of methodical and mathematical support for an atmosphere protection subsystem in the thermal power station automated process control system are considered taking as an example the problem of controlling nitrogen oxide emissions at a gas-and-oil-fired thermal power station. The combined environmental-and-economic characteristics of boilers, which correlate the costs for suppressing emissions with the boiler steam load and mass discharge of nitrogen oxides in analytic form, are used as the main tool for optimal control. A procedure for constructing and applying environmental-and-economic characteristics on the basis of technical facilities available in modern instrumentation and control systems is presented.
Deformation and Heat Transfer on Three Sides Protected Beams under Fire Accident
NASA Astrophysics Data System (ADS)
Imran, M.; Liew, M. S.; Garcia, E. M.; Nasif, M. S.; Yassin, A. Y. M.; Niazi, U. M.
2018-04-01
Fire accidents are common in oil and gas industry. The application of passive fire protection (PFP) is a costly solution. The PFP is applied only on critical structural members to optimise project cost. In some cases, beams cannot be protected from the top flange in order to accommodate for the placement of pipe supports and grating. It is important to understand the thermal and mechanical response of beam under such condition. This paper discusses the response of steel beam under ISO 834 fire protected, unprotected and three sides protected beams. The model validated against an experimental study. The experimental study has shown good agreement with FE model. The study revealed that the beams protected from three sides heat-up faster compare to fully protected beam showing different temperature gradient. However, the affects load carrying capacity are insignificant under ISO 834 fire.
Integrated Personal Protective Equipment Standards Support Model
2008-04-01
traditional SCBA showed that the distribution of the weight is important as well. Twelve firefighters performed simulated fire -fighting and rescue exercises...respiratory equipment standards and five National Fire Protection Association (NFPA) protective suit, clothing, and respirator standards. The...respirators. The clothing standards were for protective ensembles for urban search and rescue operations, open circuit SCBA for fire and emergency
14 CFR 25.854 - Lavatory fire protection.
Code of Federal Regulations, 2010 CFR
2010-01-01
... AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Design and Construction Fire Protection § 25.854 Lavatory fire protection. For airplanes with a passenger capacity of 20 or more: (a) Each lavatory must be... disposal receptacle for towels, paper, or waste, located within the lavatory. The extinguisher must be...
Sprinkler System Installer. Occupational Analyses Series.
ERIC Educational Resources Information Center
Chinien, Chris; Boutin, France
This analysis covers tasks performed by a sprinkler system installer, an occupational title some provinces and territories of Canada have also identified as pipefitter--fire protection mechanic specialty; sprinkler and fire protection installer; sprinkler and fire protection systems installer; and sprinkler fitter. A guide to analysis discusses…
14 CFR 29.1359 - Electrical system fire and smoke protection.
Code of Federal Regulations, 2010 CFR
2010-01-01
... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Equipment Electrical Systems and Equipment § 29.1359 Electrical system fire and smoke protection. (a) Components of the electrical system... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Electrical system fire and smoke protection...
Thermal Response of UHMWPE Materials in a Flash Flame Test Environment
2014-11-13
Evaluation of Flame Resistant Clothing for Protection Against Fire Simulations Using an Instrumented Manikin. Several UHMWPE fabrics were tested underneath...PROTECTIVE CLOTHING COTTON FLASH FLAMES UNDERGARMENTS TEST AND EVALUATION FABRICS FLAME TESTING FIRE ...PROTECTION FIRE RESISTANT TEXTILES UHMWPE(ULTRA HIGH MOLECULAR WEIGHT POLYETHYLENE
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dunbar, K.A.
1972-01-10
A safety survey covering the disciplines of Reactor Safety, Nuclear Criticality Safety, Health Protection and Industrial Safety and Fire Protection was conducted at the ANL-West EBR-II FEF Complex during the period January 10-18, 1972. In addition, the entire ANL-West site was surveyed for Health Protection and Industrial Safety and Fire Protection. The survey was conducted by members of the AEC Chicago Operations Office, a member of RDT-HQ and a member of the RDT-ID site office. Eighteen recommendations resulted from the survey, eleven in the area of Industrial Safety and Fire Protection, five in the area of Reactor Safety and twomore » in the area of Nuclear Criticality Safety.« less
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 17 2014-07-01 2014-07-01 false Optional SO2 Emissions Data Protocol for Gas-Fired and Oil-Fired Units D Appendix D to Part 75 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTINUOUS EMISSION MONITORING Pt. 75, App. D Appendix D to Part 75—Optional SO2 Emissions Data...
Jeremy S. Fried; J. Keith Gilless; Robert E. Martin
1987-01-01
The University of California's Department of Forestry and Resource Management, under contract with the California Department of Forestry and Fire Protection, has developed and released the first version of the California Fire Economics Simulator (CFES). The current release is adapted from the Initial Action Assessment component of the USFS's National Fire...
29 CFR Appendix A to Subpart P to... - Model Fire Safety Plan (Non-Mandatory)
Code of Federal Regulations, 2011 CFR
2011-07-01
... Subpart P to Part 1915 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH... Fire Protection in Shipyard Employment Pt. 1915, Subpt. P, App. A Appendix A to Subpart P to Part 1915... fire. D. Potential ignition sources for fires and how to control them. E. Types of fire protection...
29 CFR Appendix A to Subpart P to... - Model Fire Safety Plan (Non-Mandatory)
Code of Federal Regulations, 2010 CFR
2010-07-01
... Subpart P to Part 1915 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH... Fire Protection in Shipyard Employment Pt. 1915, Subpt. P, App. A Appendix A to Subpart P to Part 1915... fire. D. Potential ignition sources for fires and how to control them. E. Types of fire protection...
Ulrici, Luisa; Algoet, Yvon; Bruno, Luca; Magistris, Matteo
2015-04-01
The European Laboratory for Particle Physics (CERN) has operated high-energy accelerators for fundamental physics research for nearly 60 y. The side-product of this activity is the radioactive waste, which is mainly generated as a result of preventive and corrective maintenance, upgrading activities and the dismantling of experiments or accelerator facilities. Prior to treatment and disposal, it is common practice to temporarily store radioactive waste on CERN's premises and it is a legal requirement that these storage facilities are safe and secure. Waste treatment typically includes sorting, segregation, volume and size reduction and packaging, which will depend on the type of component, its chemical composition, residual activity and possible surface contamination. At CERN, these activities are performed in a dedicated waste treatment centre under the supervision of the Radiation Protection Group. This paper gives an overview of the radiation protection challenges in the conception of a temporary storage and treatment centre for radioactive waste in an accelerator facility, based on the experience gained at CERN. The CERN approach consists of the classification of waste items into 'families' with similar radiological and physical-chemical properties. This classification allows the use of specific, family-dependent techniques for radiological characterisation and treatment, which are simultaneously efficient and compliant with best practices in radiation protection. The storage was planned on the basis of radiological and other possible hazards such as toxicity, pollution and fire load. Examples are given of technical choices for the treatment and radiological characterisation of selected waste families, which could be of interest to other accelerator facilities. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Fire endurance research at the Forest Products Laboratory
R. H. White
1990-01-01
Fire endurance research activities and facilities at the FPL concern the ability of a wood member or assembly to withstand the effects of fire while acting as a fire barrier and supporting a load. Fire endurance is generally concerned with the post-flashover portion of the fire. The importance of fire endurance in fire safety is reflected in building code requirements...
Behaviour of tunnel lining material in road tunnel fire
NASA Astrophysics Data System (ADS)
Tomar, M.; Khurana, S.; Singh, R.
2018-04-01
The worldwide road tunnel linings are protected against possible fire scenarios to safeguard the structure and assist in occupant evacuation. There are various choices of active and passive protection available, passive protections includes calcium silicate boards, polypropylene fibers, vermiculite cement based sprays, and other intumescent materials. Tunnel fire is a complex phenomenon and researchers in the past has highlighted that there are various factors which affect the tunnel fires. The effect of passive protection techniques on tunnel fire is not well understood, especially for the insulation boards. It’s been understood from past research that for a heavy good vehicular (HGV) fire in the tunnel, the heat feedback effect is significant. Insulation boards may also affect the tunnel fires by altering the heat feedback effect in vehicular tunnels and hence this can affect the overall heat release rates and temperature profile inside a tunnel. This study focuses on studying the role of insulation boards in tunnel fires and evaluating its effect on overall heat release rate and tunnel temperatures.
Manual Fire Suppression Methods on Typical Machinery Space Spray Fires
1990-07-31
Aqueous Film Forming Foam Manuscnpt approved April 25, 1990. ( AFFF ), has been incorporated in machinery space fire protection systems to...distribution unlimited. 13. ABSTRACT (Maximum 200 words) A series of tests was conducted to evaluate the effectiveness of Aqueous Film Forming Foami ( AFFF ...machinery space fire protection systems to control running fuel and fuel spray fires (PKP side of TAFES), and bilge fires ( aqueous film forming foam
14 CFR 25.863 - Flammable fluid fire protection.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Flammable fluid fire protection. 25.863....863 Flammable fluid fire protection. (a) In each area where flammable fluids or vapors might escape by..., fireproof containment, or use of extinguishing agents. (5) Ability of airplane components that are critical...
14 CFR 27.863 - Flammable fluid fire protection.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Flammable fluid fire protection. 27.863....863 Flammable fluid fire protection. (a) In each area where flammable fluids or vapors might escape by..., fireproof containment, or use of extinguishing agents. (5) Ability of rotorcraft components that are...
14 CFR 27.863 - Flammable fluid fire protection.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Flammable fluid fire protection. 27.863....863 Flammable fluid fire protection. (a) In each area where flammable fluids or vapors might escape by..., fireproof containment, or use of extinguishing agents. (5) Ability of rotorcraft components that are...
14 CFR 29.863 - Flammable fluid fire protection.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Flammable fluid fire protection. 29.863... § 29.863 Flammable fluid fire protection. (a) In each area where flammable fluids or vapors might..., shutting down equipment, fireproof containment, or use of extinguishing agents. (5) Ability of rotorcraft...
14 CFR 29.863 - Flammable fluid fire protection.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Flammable fluid fire protection. 29.863... § 29.863 Flammable fluid fire protection. (a) In each area where flammable fluids or vapors might..., shutting down equipment, fireproof containment, or use of extinguishing agents. (5) Ability of rotorcraft...
14 CFR 25.863 - Flammable fluid fire protection.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Flammable fluid fire protection. 25.863....863 Flammable fluid fire protection. (a) In each area where flammable fluids or vapors might escape by..., fireproof containment, or use of extinguishing agents. (5) Ability of airplane components that are critical...
14 CFR 29.863 - Flammable fluid fire protection.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Flammable fluid fire protection. 29.863... § 29.863 Flammable fluid fire protection. (a) In each area where flammable fluids or vapors might..., shutting down equipment, fireproof containment, or use of extinguishing agents. (5) Ability of rotorcraft...
14 CFR 29.863 - Flammable fluid fire protection.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Flammable fluid fire protection. 29.863... § 29.863 Flammable fluid fire protection. (a) In each area where flammable fluids or vapors might..., shutting down equipment, fireproof containment, or use of extinguishing agents. (5) Ability of rotorcraft...
14 CFR 25.863 - Flammable fluid fire protection.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Flammable fluid fire protection. 25.863....863 Flammable fluid fire protection. (a) In each area where flammable fluids or vapors might escape by..., fireproof containment, or use of extinguishing agents. (5) Ability of airplane components that are critical...
14 CFR 27.863 - Flammable fluid fire protection.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Flammable fluid fire protection. 27.863....863 Flammable fluid fire protection. (a) In each area where flammable fluids or vapors might escape by..., fireproof containment, or use of extinguishing agents. (5) Ability of rotorcraft components that are...
14 CFR 25.863 - Flammable fluid fire protection.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Flammable fluid fire protection. 25.863....863 Flammable fluid fire protection. (a) In each area where flammable fluids or vapors might escape by..., fireproof containment, or use of extinguishing agents. (5) Ability of airplane components that are critical...
14 CFR 27.863 - Flammable fluid fire protection.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Flammable fluid fire protection. 27.863....863 Flammable fluid fire protection. (a) In each area where flammable fluids or vapors might escape by..., fireproof containment, or use of extinguishing agents. (5) Ability of rotorcraft components that are...
14 CFR 27.863 - Flammable fluid fire protection.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Flammable fluid fire protection. 27.863....863 Flammable fluid fire protection. (a) In each area where flammable fluids or vapors might escape by..., fireproof containment, or use of extinguishing agents. (5) Ability of rotorcraft components that are...
ERIC Educational Resources Information Center
Razwick, Jeff
2007-01-01
Many schools are almost entirely reliant on alarms and sprinklers for their fire protection. As these devices need to be triggered and supplied with power or water to work properly, they are vulnerable to errors. To provide adequate safety, a good fire-protection program must have three primary elements: fire protection and suppression, and…
Protection against fire in the mountainous forests of Greece case study: forest complex of W. Nestos
NASA Astrophysics Data System (ADS)
Drosos, Vasileios C.; Giannoulas, Vasileios J.; Stergiadou, Anastasia; Karagiannis, Evaggelos; Doukas, Aristotelis-Kosmas G.
2014-08-01
Forest fires are an ancient phenomenon. Appear, however, with devastating frequency and intensity over the last 30 years. In our country, the climatic conditions in combination with the intense relief, favor their rapid spread. Considering the fact that environmental conditions provided for decades even worse (increased temperature, drought and vegetation), then the problem of forest fires in our country, is expected to become more intense. The work focuses on the optimization model of the opening up of the forest mountain areas taking into account the prevention and suppression of forest fires. Research area is the mountain forest complex of W. Nestos of Drama Prefecture. The percentage of forest protection area is examined under the light whether the total hose length corresponds to the actual operational capacity to reach a fire source. For this reason are decided to present a three case study concerning area of the forest being protected by fire extinguishing vehicles. The first one corresponds to a fire suppression bandwidth (buffer zone) with a capacity radius of 150m uphill and 250m downhill from the origin point where the fire extinguishing vehicle stands. The second one corresponds to a fire suppression capacity of 200m uphill and 400m downhill and the third one corresponds to a fire suppression capacity of 300m uphill and 500m downhill. The most important forest technical infrastructures to prevent fire are roads network (opening up) for fire protection and buffer zones. Patrols of small and agile 4 × 4 appropriately equipped (pipe length of 500 meters and putting pressure on uphill to 300 meters) for the first attack of the fire in the summer months coupled with early warning of fire observatories adequately cover the forest protection of W. Nestos complex. But spatial distribution needed improvements to a road density of the optimum economic Dec, both forest protection and for better management (skidding) of woody capital.
NASA Astrophysics Data System (ADS)
Zhao, Mengmeng
2017-12-01
The thermal protective performance of the fire fighter protective clothing is of vital importance for fire fighters. In the study fabrics treated by phase change materials (PCMs) were applied in the multi-layered fabrics of the fire fighter protective clothing ensemble. The PCM fabrics were placed at the different layers of the clothing and their thermal protective performance were measured by a TPP tester. Results show that with the application of the PCM fabrics the thermal protection of the multi-layered fabrics was greatly increased. The time to reach a second degree burn was largely reduced. The location of the PCM fabrics at the different layers did not affect much on the thermal protective performance. The higher amount of the PCM adds on, the higher thermal protection was brought. The fabrics with PCMs of a higher melting temperature could contribute to higher thermal protection.
24 CFR 232.515 - Refund of fees.
Code of Federal Regulations, 2011 CFR
2011-04-01
... INSURANCE FOR NURSING HOMES, INTERMEDIATE CARE FACILITIES, BOARD AND CARE HOMES, AND ASSISTED LIVING FACILITIES Eligibility Requirements-Supplemental Loans To Finance Purchase and Installation of Fire Safety... that the installation of fire safety equipment for the project has been prevented because of...
2015-03-02
Corps of Engineers Joint Base Andrews-Naval Air Facility Final EA – Firing Range October 2014 v WSSC Washington Suburban Sanitary Commission...are leaving the site with waste residue still on their skin and uniforms. Per section 7.6.1.7 [Latrines ( Sanitary Facilities)] in ETL 11-18 (Small...served by water, sanitary sewer, and power. A fire hydrant exists on the site, while another hydrant exists at the intersection of the entry road and
Zhang, Xin; Peng, Lei; Ni, Zhao-peng; Ni, Tian-xiao; Huang, Yi-liang; Zhou, Yang
2018-01-01
Experimental research was conducted to study the fire resistance of steel tubular columns used in prefabricated and modular construction. In order to achieve high-efficient prefabrication and fast on-site installation, membrane protections using board products and thermal insulation blankets are adopted as the favorable protection method. Three protected tubular columns were tested in a full-scale column furnace with axial load applied. The study variables were different membranes, including fiber reinforced calcium silicate (FRCS) boards, rock wool and aluminum silica (Fiberfrax) insulations. The results suggest that one layer of 12 mm FRCS board with rock wool insulation has insufficient fire protection. However, steel columns protected with two layers of 12 mm FRCS boards with insulation appeared to have good fire resistances and could achieve a fire resistance rating as high as 2.5~3.0 h. PMID:29547574
Modeling heat and moisture transport in firefighter protective clothing during flash fire exposure
NASA Astrophysics Data System (ADS)
Chitrphiromsri, Patirop; Kuznetsov, Andrey V.
2005-01-01
In this paper, a model of heat and moisture transport in firefighter protective clothing during a flash fire exposure is presented. The aim of this study is to investigate the effect of coupled heat and moisture transport on the protective performance of the garment. Computational results show the distribution of temperature and moisture content in the fabric during the exposure to the flash fire as well as during the cool-down period. Moreover, the duration of the exposure during which the garment protects the firefighter from getting second and third degree burns from the flash fire exposure is numerically predicted. A complete model for the fire-fabric-air gap-skin system is presented.
77 FR 31325 - National Fire Codes: Request for Comments on NFPA Technical Committee Reports
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-25
... DEPARTMENT OF COMMERCE National Institute of Standards and Technology National Fire Codes: Request... publishing this notice on behalf of the National Fire Protection Association (NFPA) to announce the... National Fire Protection Association (NFPA) has accomplished its mission by advocating scientifically based...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-14
... Protection of Stratospheric Ozone: Listing of Substitutes for Ozone Depleting Substances--Fire Suppression... a companion proposed rule issuing listings for three fire suppressants under EPA's Significant New... companion proposed rule issuing listings for three fire suppressants under EPA's Significant New...
Cast Coil Transformer Fire Susceptibility and Reliability Study
1991-04-01
transformers reduce risk to the user compared to liquid-filled units, eliminate environmental impacts, are more efficient than most transformer designs, and...filled units, eliminate environmental impacts, arc more efficient than most transformer designs, and add minimal risk to the facility in a fire situation...add minimal risk to the facility in a fire situation. Cast coil transformers have a long record of operation and have proven to be reliable and
NASA Astrophysics Data System (ADS)
Lee, A.; Jung, N. S.; Mokhtari Oranj, L.; Lee, H. S.
2018-06-01
The leakage of radioactive materials generated at particle accelerator facilities is one of the important issues in the view of radiation safety. In this study, fire and flooding at particle accelerator facilities were considered as the non-radiation disasters which result in the leakage of radioactive materials. To analyse the expected effects at each disaster, the case study on fired and flooded particle accelerator facilities was carried out with the property investigation of interesting materials presented in the accelerator tunnel and the activity estimation. Five major materials in the tunnel were investigated: dust, insulators, concrete, metals and paints. The activation levels on the concerned materials were calculated using several Monte Carlo codes (MCNPX 2.7+SP-FISPACT 2007, FLUKA 2011.4c and PHITS 2.64+DCHAIN-SP 2001). The impact weight to environment was estimated for the different beam particles (electron, proton, carbon and uranium) and the different beam energies (100, 430, 600 and 1000 MeV/nucleon). With the consideration of the leakage path of radioactive materials due to fire and flooding, the activation level of selected materials, and the impacts to the environment were evaluated. In the case of flooding, dust, concrete and metal were found as a considerable object. In the case of fire event, dust, insulator and paint were the major concerns. As expected, the influence of normal fire and flooding at electron accelerator facilities would be relatively low for both cases.
George Chen
2009-01-01
Thermal condensation of glucose-diammonium phosphate in wood at 160 and 190[degrees]C will protect wood against fire and decay in one treatment using an aqueous system. For fire protection, treatments at 160 or 190[degrees]C led to low flammability as evidenced by fire-tube tests. For nonleached wood, weight losses were 1.9, 2.0, and 2.0% with chemical retentions of 56...
Smoke Alarms for People Who Are Deaf or Hard-of-Hearing
... motels Expand sub-navigation Hotel fire safety tips Marijuana grow & extraction facilities Nightclubs and other assembly occupancies ... Fire behavior research Fire loss and injury research Benefits of home fire sprinklers Expand sub-navigation Environmental ...
Forest fire laboratory at Riverside and fire research in California: past, present, and future
Carl C. Wilson; James B. Davis
1988-01-01
The need for protection from uncontrolled fire in California was identified by Abbott Kinney, Chairman of the State Board of Forestry, more than 75 years before the construction of the Riverside Forest Fire Laboratory. With the organization of the USDA Forest Service the need for an effective fire protection organization became apparent. In response, a...
2003-01-10
This final rule amends the fire safety standards for hospitals, long-term care facilities, intermediate care facilities for the mentally retarded, ambulatory surgery centers, hospices that provide inpatient services, religious nonmedical health care institutions, critical access hospitals, and Programs of All-Inclusive Care for the Elderly facilities. Further, this final rule adopts the 2000 edition of the Life Safety Code and eliminates references in our regulations to all earlier editions.
14 CFR 29.863 - Flammable fluid fire protection.
Code of Federal Regulations, 2010 CFR
2010-01-01
... AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Design and Construction Fire Protection... sources, including electrical faults, overheating of equipment, and malfunctioning of protective devices...
CONCEPTUAL DESIGN ASSESSMENT FOR THE CO-FIRING OF BIO-REFINERY SUPPLIED LIGNIN PROJECT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ted Berglund; Jeffrey T. Ranney; Carol L. Babb
2001-04-01
The major aspects of this project are proceeding toward completion. Prior to this quarter, design criteria, tentative site selection, facility layout, and preliminary facility cost estimates have been completed and issued for review. Processing of bio-solids was completed, providing material for the pilot operations. Pilot facility design, equipment selection, and modification were completed during the fourth quarter of 2000. Initial pilot facility shakedown was completed during the fourth quarter. After some unavoidable delays, a suitable representative supply of municipal solid waste (MSW) feed material was procured. During this quarter (first quarter of 2001), shredding of the feed material was completedmore » and final feed conditioning was completed. Pilot facility hydrolysis production was completed to produce lignin for co-fire testing. Pilot facility modifications continued to improve facility operations and performance during the first quarter of 2001. Samples of the co-fire fuel material were sent to the co-fire facility for evaluation. The TVA-Colbert facility has neared completion of the task to evaluate the co-location of the Masada facility on the operation of the power generation facility. The TVA-Colbert fossil plant is fully capable of providing a reliable steam supply. The preferred steam supply connection points and steam pipeline routing have been identified. The environmental review of the pipeline routing has been completed and no major impacts have been identified. Detailed assessment of steam export impacts on the Colbert boiler system have been completed and a cost estimate for steam supply system is being developed.« less
30 CFR 77.1916 - Welding, cutting, and soldering; fire protection.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Welding, cutting, and soldering; fire... OF UNDERGROUND COAL MINES Slope and Shaft Sinking § 77.1916 Welding, cutting, and soldering; fire protection. (a) One portable fire extinguisher shall be provided where welding, cutting, or soldering with...
New fire retardant foams and intumescents
NASA Technical Reports Server (NTRS)
Parker, J. A.
1972-01-01
The development of fire retardant foams and intumescent paints for protection of commercial aircraft passengers in the event of fire is discussed. Recommended materials and methods for evaluating the effectiveness of the materials are presented. Typical problems resulting from aircraft fires and the basic protective mechanisms to cope with these problems are examined.
77 FR 67628 - National Fire Codes: Request for Public Input for Revision of Codes and Standards
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-13
... DEPARTMENT OF COMMERCE National Institute of Standards and Technology National Fire Codes: Request... Technology, Commerce. ACTION: Notice. SUMMARY: This notice contains the list of National Fire Protection... the National Fire Protection Association (NFPA) to announce the NFPA's proposal to revise some of its...
78 FR 24729 - National Fire Codes: Request for Comments on NFPA's Codes and Standards
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-26
... DEPARTMENT OF COMMERCE National Institute of Standards and Technology National Fire Codes: Request... this notice on behalf of the National Fire Protection Association (NFPA) to announce the availability...: Since 1896, the National Fire Protection Association (NFPA) has accomplished its mission by advocating...
78 FR 24725 - National Fire Codes: Request for Public Input for Revision of Codes and Standards
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-26
... DEPARTMENT OF COMMERCE National Institute of Standards and Technology National Fire Codes: Request... Technology, Commerce. ACTION: Notice. SUMMARY: This notice contains the list of National Fire Protection... the National Fire Protection Association (NFPA) to announce the NFPA's proposal to revise some of its...
76 FR 22381 - National Fire Codes: Request for Comments on NFPA Technical Committee Reports
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-21
... DEPARTMENT OF COMMERCE National Institute of Standards and Technology National Fire Codes: Request... publishing this notice on behalf of the National Fire Protection Association (NFPA) to announce the..., Massachusetts 02169-7471, (617) 770-3000. SUPPLEMENTARY INFORMATION: Since 1896, the National Fire Protection...
Managing the Library Fire Risk.
ERIC Educational Resources Information Center
Morris, John
A discussion of fire risks, causes, prevention, and salvage in libraries is presented in text and photographs. A description of some historic library fires demonstrates the value of adequate protection and preparedness programs to minimize loss and damage. The need for fire retardant construction and protection from valdalism and arson are…
30 CFR 77.1916 - Welding, cutting, and soldering; fire protection.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Welding, cutting, and soldering; fire... OF UNDERGROUND COAL MINES Slope and Shaft Sinking § 77.1916 Welding, cutting, and soldering; fire protection. (a) One portable fire extinguisher shall be provided where welding, cutting, or soldering with...
30 CFR 77.1916 - Welding, cutting, and soldering; fire protection.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Welding, cutting, and soldering; fire... OF UNDERGROUND COAL MINES Slope and Shaft Sinking § 77.1916 Welding, cutting, and soldering; fire protection. (a) One portable fire extinguisher shall be provided where welding, cutting, or soldering with...
30 CFR 77.1916 - Welding, cutting, and soldering; fire protection.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Welding, cutting, and soldering; fire... OF UNDERGROUND COAL MINES Slope and Shaft Sinking § 77.1916 Welding, cutting, and soldering; fire protection. (a) One portable fire extinguisher shall be provided where welding, cutting, or soldering with...
30 CFR 77.1916 - Welding, cutting, and soldering; fire protection.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Welding, cutting, and soldering; fire... OF UNDERGROUND COAL MINES Slope and Shaft Sinking § 77.1916 Welding, cutting, and soldering; fire protection. (a) One portable fire extinguisher shall be provided where welding, cutting, or soldering with...
Alvarado, Swanni T; Silva, Thiago Sanna Freire; Archibald, Sally
2018-07-15
Humans can alter fire dynamics in grassland systems by changing fire frequency, fire seasonality and fuel conditions. These changes have effects on vegetation structure and recovery, species composition, and ecosystem function. Understanding how human management can affect fire regimes is vital to detect potential changes in the resilience of plant communities, and to predict vegetation responses to human interventions. We evaluated the fire regimes of two recently protected areas in Madagascar (Ibity and Itremo NPA) and one in Brazil (Serra do Cipó NP) before and after livestock exclusion and fire suppression policies. We compare the pre- and post-management fire history in these areas and analyze differences in terms of total annual burned area, density of ignitions, burn scar size distribution, fire return period and seasonal fire distribution. More than 90% of total park areas were burned at least once during the studied period, for all parks. We observed a significant reduction in the number of ignitions for Ibity NPA and Serra do Cipó NP after livestock exclusion and active fire suppression, but no significant change in total burned area for each protected area. We also observed a seasonal shift in burning, with fires happening later in the fire season (October-November) after management intervention. However, the protected areas in Madagascar had shorter fire return intervals (3.23 and 1.82 years) than those in Brazil (7.91 years). Our results demonstrate that fire exclusion is unattainable, and probably unwarranted in tropical grassland conservation areas, but show how human intervention in fire and vegetation patterns can alter various aspects of the fire regimes. This information can help with formulating realistic and effective fire management policies in these valuable conservation areas. Copyright © 2018 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Reddy, C. Sudhakar; Padma Alekhya, V. V. L.; Saranya, K. R. L.; Athira, K.; Jha, C. S.; Diwakar, P. G.; Dadhwal, V. K.
2017-02-01
Carbon emissions released from forest fires have been identified as an environmental issue in the context of global warming. This study provides data on spatial and temporal patterns of fire incidences, burnt area and carbon emissions covering natural vegetation types (forest, scrub and grassland) and Protected Areas of India. The total area affected by fire in the forest, scrub and grasslands have been estimated as 48765.45, 6540.97 and 1821.33 km 2, respectively, in 2014 using Resourcesat-2 AWiFS data. The total CO 2 emissions from fires of these vegetation types in India were estimated to be 98.11 Tg during 2014. The highest emissions were caused by dry deciduous forests, followed by moist deciduous forests. The fire season typically occurs in February, March, April and May in different parts of India. Monthly CO 2 emissions from fires for different vegetation types have been calculated for February, March, April and May and estimated as 2.26, 33.53, 32.15 and 30.17 Tg, respectively. Protected Areas represent 11.46% of the total natural vegetation cover of India. Analysis of fire occurrences over a 10-year period with two types of sensor data, i.e., AWiFS and MODIS, have found fires in 281 (out of 614) Protected Areas of India. About 16.78 Tg of CO 2 emissions were estimated in Protected Areas in 2014. The natural vegetation types of Protected Areas have contributed for burnt area of 17.3% and CO 2 emissions of 17.1% as compared to total natural vegetation burnt area and emissions in India in 2014. 9.4% of the total vegetation in the Protected Areas was burnt in 2014. Our results suggest that Protected Areas have to be considered for strict fire management as an effective strategy for mitigating climate change and biodiversity conservation.
Reserves Protect against Deforestation Fires in the Amazon
Adeney, J. Marion; Christensen, Norman L.; Pimm, Stuart L.
2009-01-01
Background Reserves are the principal means to conserve forests and biodiversity, but the question of whether reserves work is still debated. In the Amazon, fires are closely linked to deforestation, and thus can be used as a proxy for reserve effectiveness in protecting forest cover. We ask whether reserves in the Brazilian Amazon provide effective protection against deforestation and consequently fires, whether that protection is because of their location or their legal status, and whether some reserve types are more effective than others. Methodology/Principal Findings Previous work has shown that most Amazonian fires occur close to roads and are more frequent in El Niño years. We quantified these relationships for reserves and unprotected areas by examining satellite-detected hot pixels regressed against road distance across the entire Brazilian Amazon and for a decade with 2 El Niño-related droughts. Deforestation fires, as measured by hot pixels, declined exponentially with increasing distance from roads in all areas. Fewer deforestation fires occurred within protected areas than outside and the difference between protected and unprotected areas was greatest near roads. Thus, reserves were especially effective at preventing these fires where they are known to be most likely to burn; but they did not provide absolute protection. Even within reserves, at a given distance from roads, there were more deforestation fires in regions with high human impact than in those with low impact. The effect of El Niño on deforestation fires was greatest outside of reserves and near roads. Indigenous reserves, limited-use reserves, and fully protected reserves all had fewer fires than outside areas and did not appear to differ in their effectiveness. Conclusions/Significance Taking time, regional factors, and climate into account, our results show that reserves are an effective tool for curbing destructive burning in the Amazon. PMID:19352423
46 CFR 28.825 - Excess fire detection and protection equipment.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 1 2010-10-01 2010-10-01 false Excess fire detection and protection equipment. 28.825... equipment. Instead of meeting the requirements of § 28.155, each vessel to which this subpart applies must meet the following requirements: (a) Installation of fire detection and protection equipment in excess...
Spacecraft fire-safety experiments for space station: Technology development mission
NASA Technical Reports Server (NTRS)
Youngblood, Wallace W.
1988-01-01
Three concept designs for low-gravity, fire-safety related experiments are presented, as selected for the purpose of addressing key issues of enhancing safety and yet encouraging access to long-duration, manned spacecraft such as the NASA space station. The selected low-gravity experiments are the following: (1) an investigation of the flame-spread rate and combustion-product evolution of the burning of typical thicknesses of spacecraft materials in very low-speed flows; (2) an evaluation of the interaction of fires and candidate extinguishers in various fire scenarios; and (3) an investigation of the persistence and propagation of smoldering and deep-seated combustion. Each experiment is expected to provide fundamental combustion-science data, as well as the fire-safety applications, and each requires the unique long-duration, low-gravity environment of the space station. Two generic test facilities, i.e., the Combustion Tunnel Facility and the Combustion Facility, are proposed for space station accommodation to support the selected experiments. In addition, three near-term, fire-safety related experiments are described along with other related precursor activities.
Rx fire laws: tools to protect fire: the `ecological imperative?
Dale Wade; Steven Miller; Johnny Stowe; James Brenner
2006-01-01
The South is the birthplace of statutes and ordinances that both advocate and protect the cultural heritage of woods burning, which has been practiced in this region uninterrupted for more than 10,000 years. We present a brief overview of fire use in the South and discuss why most southern states recognized early on that periodic fire was necessary to sustain fire...
Facilities and Methods Used in Full-scale Airplane Crash-fire Investigation
NASA Technical Reports Server (NTRS)
Black, Dugald O.
1952-01-01
The facilities and the techniques employed in the conduct of full scale airplane crash-fire studies currently being conducted at the NACA Lewis laboratory are discussed herein. This investigation is part of a comprehensive study of the airplane crash-fire problem. The crash configuration chosen, the general physical layout of the crash site, the test methods, the instrumentation, the data-recording systems, and the post-crash examination procedure are described
42 CFR 403.744 - Condition of participation: Life safety from fire.
Code of Federal Regulations, 2010 CFR
2010-10-01
... written fire control plans that contain provisions for prompt reporting of fires; extinguishing fires...) The RNHCI must maintain written evidence of regular inspection and approval by State or local fire... contrary, the RNHCI may place alcohol-based hand rub dispensers in its facility if— (i) Use of alcohol...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 36 Parks, Forests, and Public Property 3 2010-07-01 2010-07-01 false Fires. 331.15 Section 331.15... INDIANA § 331.15 Fires. Open fires are prohibited unless confined to fireplaces, grills, or other facilities designed for this purpose as designated by the District Engineer. Fires shall not be left...
Fire Safety. Managing School Facilities, Guide 6.
ERIC Educational Resources Information Center
Department for Education and Employment, London (England). Architects and Building Branch.
This booklet discusses how United Kingdom schools can manage fire safety and minimize the risk of fire. The guide examines what legislation school buildings must comply with and covers the major risks. It also describes training and evacuation procedures and provides guidance on fire precautions, alarm systems, fire fighting equipment, and escape…
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-12
... Status Materials Science Technology, Inc. (Specialty Elastomers and Fire Retardant Chemicals) Conroe... specialty elastomer manufacturing and distribution facility of Materials Science Technology, Inc., located... and distribution of specialty elastomers and fire retardant chemicals at the facility of Materials...
30 CFR 75.1107-8 - Fire suppression devices; extinguishant supply systems.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Protection Fire Suppression Devices and Fire-Resistant Hydraulic Fluids on Underground Equipment § 75.1107-8... liquid chemical to protect attended equipment shall: (1) Be maintained at a pressure consistent with the...
30 CFR 75.1107-8 - Fire suppression devices; extinguishant supply systems.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Protection Fire Suppression Devices and Fire-Resistant Hydraulic Fluids on Underground Equipment § 75.1107-8... liquid chemical to protect attended equipment shall: (1) Be maintained at a pressure consistent with the...
Environmental justice regulations draw fire
NASA Astrophysics Data System (ADS)
Showstack, Randy
Advocates of “environmental justice” say that proposed U.S. Environmental Protection Agency (EPA) regulations are necessary to ensure that an unfair share of industrial facilities and waste plants are not sited in poor and minority communities, as they claim has occurred in the past.However, a number of state and local government agencies, business groups, and Democratic and Republican politicians argue that EPA guidelines—written to put some teeth into the Title VI clause of the Civil Rights Act that prohibits discrimination in all federally funded programs and activities—are unworkable and need to be overhauled.
Environmental justice regulations draw fire
NASA Astrophysics Data System (ADS)
Showstack, Randy
Advocates of "environmental justice" say that proposed U.S. Environmental Protection Agency (EPA) regulations are necessary to ensure that an unfair share of industrial facilities and waste plants are not sited in poor and minority communities, as they claim has occurred in the past.However, a number of state and local government agencies, business groups, and Democratic and Republican politicians argue that EPA guidelines—written to put some teeth into the Title VI clause of the Civil Rights Act that prohibits discrimination in all federally funded programs and activities—are unworkable and need to be overhauled.
14 CFR 25.863 - Flammable fluid fire protection.
Code of Federal Regulations, 2010 CFR
2010-01-01
... AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Design and Construction Fire Protection § 25..., including electrical faults, overheating of equipment, and malfunctioning of protective devices. (4) Means...
Exposure of a liquefied gas container to an external fire.
Raj, Phani K
2005-06-30
In liquefied gas, bulk-storage facilities and plants, the separation distances between storage tanks and between a tank and a line of adjoining property that can be built are governed by local regulations and/or codes (e.g. National Fire Protection Association (NFPA) 58, 2004). Separation distance requirements have been in the NFPA 58 Code for over 60 years; however, no scientific foundations (either theoretical or experimental) are available for the specified distances. Even though the liquefied petroleum gas (LPG) industry has operated safely over the years, there is a question as to whether the code-specified distances provide sufficient safety to LPG-storage tanks, when they are exposed to large external fires. A radiation heat-transfer-based model is presented in this paper. The temporal variation of the vapor-wetted tank-wall temperature is calculated when exposed to thermal radiation from an external, non-impinging, large, 30.5 m (100 ft) diameter, highly radiative, hydrocarbon fuel (pool) fire located at a specified distance. Structural steel wall of a pressurized, liquefied gas container (such as the ASME LP-Gas tank) begins to lose its strength, when the wall temperature approaches a critical temperature, 810 K (1000 degrees F). LP-Gas tank walls reaching close to this temperature will be a cause for major concern because of increased potential for tank failure, which could result in catastrophic consequences. Results from the model for exposure of different size ASME (LP-Gas) containers to a hydrocarbon pool fire of 30.5 m (100 ft) in diameter, located with its base edge at the separation distances specified by NFPA 58 [NFPA 58, Liquefied Petroleum Gas Code, Table 6.3.1, 2004 ed., National Fire Protection Association, Quincy, MA, 2004] indicate that the vapor-wetted wall temperature of the containers never reach the critical temperature under common wind conditions (0, 5 and 10 m/s), with the flame tilting towards the tank. This indicates that the separation distances specified in the code are adequate for non-impingement type of fires. The model can be used to test the efficacy of other similar codes and regulations for other materials.
46 CFR 28.380 - General structural fire protection.
Code of Federal Regulations, 2010 CFR
2010-10-01
... accommodation space must be separated from machinery and fuel tank spaces by a fire resistant boundary which... 46 Shipping 1 2010-10-01 2010-10-01 false General structural fire protection. 28.380 Section 28..., 1991, and That Operate With More Than 16 Individuals on Board § 28.380 General structural fire...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-29
... for OMB Review; Comment Request; Fire Protection in Underground Coal Mines ACTION: Notice. SUMMARY... information collection request (ICR) revision titled, ``Fire Protection in Underground Coal Mines,'' to the... sections of part 75 require fire drills to be conducted quarterly, equipment to be tested, and a record to...
Louhevaara, V; Ilmarinen, R; Griefahn, B; Künemund, C; Mäkinen, H
1995-01-01
Every fire fighter needs to wear fire-protective clothing and a self-contained breathing apparatus (SCBA) several times a year while carrying out various fire-fighting and rescue operations in hazardous work environments. The aim of the present study was to quantify the effects of a multilayer turnout suit designed to fulfil European standard EN 469 used over standardized (Nordic) clothing and with SCBA (total mass 25.9 kg) on maximal physical work performance, and to evaluate the relationship between individual characteristics and power output with the fire-protective clothing system and SCBA. The subjects were 12 healthy firemen aged 26-46 years. The range of their body mass, body fat and maximal oxygen consumption was 69-101 kg, 10-20% and 2.70-5.86 l.min-1, respectively. The maximal tests without (control) and with the fire-protective clothing system and SCBA were carried out on a treadmill in a thermoneutral environment. When compared to the control test, the decrease in the maximal power output in terms of maximal working time and walking speed averaged 25% (P < 0.001) varying from 18% to 34% with the fire-protective clothing system and SCBA. At maximum, no significant differences were found in pulmonary ventilation, absolute oxygen consumption, the respiratory exchange ratio, heart rate, systolic blood pressure, the rate-pressure product, mechanical efficiency, and the rating of perceived exertion between the tests with and without the fire-protective clothing system and SCBA. The reduction of the power output was related to the extra mass of the fire protective clothing and SCBA.(ABSTRACT TRUNCATED AT 250 WORDS)
Crew Exploration Vehicle Environmental Control and Life Support Fire Protection Approach
NASA Technical Reports Server (NTRS)
Lewis, John F.; Barido, Richard; Tuan, George C.
2007-01-01
As part of preparing for the Crew Exploration Vehicle (CEV), the National Aeronautics and Space Administration (NASA) worked on developing the requirements to manage the fire risk. The new CEV poses unique challenges to current fire protection systems. The size and configuration of the vehicle resembles the Apollo capsule instead of the current Space Shuttle or the International Space Station. The smaller free air volume and fully cold plated avionic bays of the CEV requires a different approach in fire protection than the ones currently utilized. The fire protection approach discussed in this paper incorporates historical lessons learned and fire detection and suppression system design philosophy spanning from Apollo to the International Space Station. Working with NASA fire and materials experts, this approach outlines the best requirements for both the closed out area of the vehicle, such as the avionics bay, and the crew cabin area to address the unique challenges due to the size and configuration of the CEV.
DOE Office of Scientific and Technical Information (OSTI.GOV)
R.V.K. Singh; V.K. Singh
2004-10-15
Spontaneous combustion in coal mines plays a vital role in occurrences of fire. Fire in coal, particularly in opencast mines, not only causes irreparable loss of national wealth but damages the surface structure and pollutes the environment. The problem of spontaneous combustion/fire in opencast coal benches is acute. Presently over 75% of the total production of coal in Indian mines is being carried out by opencast mining. Accordingly a mechanised spraying device has been developed for spraying the fire protective coating material for preventing spontaneous combustion in coal benches of opencast mines jointly by Central Mining Research Institute, Dhanbad andmore » M/s Signum Fire Protection (India) Pvt. Ltd., Nagpur under Science & Technology (S&T) project funded by Ministry of Coal, Govt. of India. The objective of this paper is to describe in detail about the mechanised spraying device and its application for spraying fire protective coating material in the benches of opencast coal mines for preventing spontaneous combustion/fire.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1981-08-01
This report presents the results of tests for polynuclear aromatic hydrocarbons (PAH) and inorganic trace elements in the effluent of eleven coal stoker fired boilers. These data are part of a larger stoker test program whose main objective was to produce information which will increase the ability of the boiler manufacturers to design and fabricate stoker boilers that are an economical and environmentally satisfactory alternative to oil and gas-fired units. The objectives of the SASS testing portion of this program are to determine the organic and inorganic makeup of boiler emissions which cannot be detected by using the standard EPAmore » Method 5 train. SASS tests were conducted in accordance with EPA Level 1 guidelines. Twenty-three SASS tests were run on 11 different coal stoker fired boilers to determine emissions data for 74 inorganic trace elements and 21 PAHs. The emissions of most concern are the suspected carcinogens or the emissions with high probability of being carcinogens. The inorganic trace elements that were investigated and are listed as carcinogens and high probability carcinogens by the Office of Air Quality Planning and Standards are: arsenic, beryllium, cadmium, and nickel. The SASS emissions data are presented in three different sets of units: nonograms per joule of energy input, micrograms per dry standard cubic meter of flue gas sampled, and grams per kilograms of fuel input. To protect the interests of the host boiler facilities, each site has been given a letter designation. A complete description of each unit and all tests run at each site can be found in the corresponding site reports referenced at the end of this report. This report contains a description of the test equipment and procedures, analytical procedures, data reduction techniques, the test data, and a brief description of each facility tested and the coals fired. 4 figures, 16 tables.« less
Safer Aviation Materials Tested
NASA Technical Reports Server (NTRS)
Palaszewski, Bryan A.
2001-01-01
A series of thermally stable polymer samples were tested. These materials are called low heat release materials and are designed for aircraft interior decorative materials. The materials are designed to give off a minimum amount of noxious gases when heated, which increases the possibility that people can escape from a burning aircraft. New cabin materials have suitably low heat release so that fire does not spread, toxic chemicals are not given off, and the fire-emergency escape time for crew and passengers is lengthened. These low heat-release materials have a variety of advantages and applications: interiors for ground-based facilities, interiors of space vehicles, and many commercial fire-protection environments. A microscale combustion calorimeter at the Federal Aviation Administration's (FAA) Technical Center tested NASA Langley Research Center materials samples. The calorimeter is shown. A sharp, quantitative, and reproducible heat-release-rate peak is obtained in the microscale heat-release-rate test. The newly tested NASA materials significantly reduced the heat release capacity and total heat release. The thermal stability and flammability behavior of the samples was very good. The new materials demonstrated a factor of 4 reduction in total heat release over ULTEM (a currently used material). This information is provided in the following barchart. In other tests, the materials showed greater than a factor 9 reduction in heat-release capacity over ULTEM. The newly tested materials were developed for low dielectric constant, low color, and good solubility. A scale up of the material samples is needed to determine the repeatability of the performance in larger samples. Larger panels composed of the best candidate materials will be tested in a larger scale FAA Technical Center fire facility. The NASA Glenn Research Center, Langley (Jeff Hinkley), and the FAA Technical Center (Richard Lyon) cooperatively tested these materials for the Accident Mitigation aspects of Fire Prevention under NASA's Aviation Safety Program.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false What are the structural fire protection requirements for accommodation spaces and modules? 149.641 Section 149.641 Navigation and... national consensus standard, as that term is defined in 29 CFR 1910.2, for the structural fire protection...
Zebra Mussel Chemical Control Guide, Version 2.0
2015-07-01
delivery systems, including potable water treatment, agriculture, industry, power generation, and fire protection. Since this invasive organism’s...delivery systems, including potable water treatment, agriculture, industry, power generation, and fire protection (Mackie and Claudi 2010). Zebra mussels...generators, pipes, valves, sensing equipment (level, flow, and pressure) and fire protection (Mackie and Claudi 2010; Prescott et al. 2014). Other USACE
NASA Astrophysics Data System (ADS)
DaCamara, Carlos; Trigo, Ricardo; Nunes, Sílvia; Pinto, Miguel; Oliveira, Tiago; Almeida, Rui
2017-04-01
In Portugal, like in Mediterranean Europe, fire activity is a natural phenomenon linking climate, humans and vegetation and is therefore conditioned by natural and anthropogenic factors. Natural factors include topography, vegetation cover and prevailing weather conditions whereas anthropogenic factors encompass land management practices and fire prevention policies. Land management practices, in particular the inadequate use of fire, is a crucial anthropogenic factor that accounts for about 90% of fire ignitions. Fire prevention policies require adequate and timely information about wildfire potential assessment, which is usually based on fire danger rating systems that provide indices to be used on an operational and tactical basis in decision support systems. We present a new website designed to provide the user community with relevant real-time information on fire activity and meteorological fire danger that will allow adopting the adequate measures to mitigate fire damage. The fire danger product consists of forecasts of fire danger over Portugal based on a statistical procedure that combines information about fire history derived from the Fire Radiative Power product disseminated by the Land Surface Analysis Satellite Application Facility (LSA SAF) with daily meteorological forecasts provided by the European Centre for Medium-Range Weather Forecasts (ECMWF). The aim of the website is fourfold; 1) to concentrate all information available (databases and maps) relevant to fire management in a unique platform so that access by end users becomes easier, faster and friendlier; 2) to supervise the access of users to the different products available; 3) to control and assist the access to the platform and obtain feedbacks from users for further improvements; 4) to outreach the operational community and foster the use of better information that increase efficiency in risk management. The website is sponsored by The Navigator Company, a leading force in the global pulp and paper market. Since the operational start of the website, the number of registered users has been steadily increasing up to a total of 300 users from a wide community that encompasses forest managers, firemen and civil protection officers, personnel from municipalities, academic researchers and private owners.
CONCEPTUAL DESIGN ASSESSMENT FOR THE CO-FIRING OF BIO-REFINERY SUPPLIED LIGNIN PROJECT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ted Berglund; Jeffrey T. Ranney; Carol L. Babb
2002-04-01
The major aspects of this project are proceeding toward completion. Prior to this quarter, design criteria, tentative site selection, facility layout, and preliminary facility cost estimates were completed and issued. Processing of bio-solids was completed, providing material for the pilot operations. Pilot facility hydrolysis production has been completed to produce lignin for co-fire testing and the lignin fuel was washed and dewatered. Both the lignin and bio-solids fuel materials for co-fire testing were sent to the co-fire facility (EERC) for evaluation and co-firing. EERC has received coal typical of the fuel to the TVA-Colbert boilers. This material was used atmore » EERC as baseline material and for mixing with the bio-fuel for combustion testing. All the combustion and fuel handling tests at EERC have been completed. During fuel preparation EERC reported no difficulties in fuel blending and handling. Preliminary co-fire test results indicate that the blending of lignin and bio-solids with the Colbert coal blend generally reduces NO{sub x} emissions, increases the reactivity of the coal, and increases the ash deposition rate on superheater surfaces. Deposits produced from the fuel blends, however, are more friable and hence easier to remove from tube surfaces relative to those produced from the baseline Colbert coal blend. The final co-fire testing report is being prepared at EERC and will be completed by the end of the second quarter of 2002. The TVA-Colbert facility has neared completion of the task to evaluate co-location of the Masada facility on the operation of the power generation facility. The TVA-Colbert fossil plant is fully capable of providing a reliable steam supply. The preferred steam supply connection points and steam pipeline routing have been identified. The environmental review of the pipeline routing has been completed and no major impacts have been identified. Detailed assessment of steam export impacts on the Colbert boiler system have been completed and a cost estimate for the steam supply system was completed. The cost estimate and output and heat rate impacts have been used to determine a preliminary price for the exported steam. TVA is further evaluating the impacts of adding lignin to the coal fuel blend and how the steam cost is impacted by proximity of the Masada biomass facility.« less
76 FR 10246 - Updating Fire Safety Standards
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-24
... DEPARTMENT OF VETERANS AFFAIRS 38 CFR Parts 17 and 59 RIN 2900-AN57 Updating Fire Safety Standards... regulations and update the standards for VA approval of such facilities, including standards for fire safety... to ``RIN 2900-AN57--Updating Fire Safety [[Page 10247
ERIC Educational Resources Information Center
Pribyl, Paul F.
Practical skills tests are provided for fire fighter trainees in the Wisconsin Fire Service Certification Series, Fire Fighter Levels I, II, and III. A course introduction appears first and contains this information: recommended instructional sequence, required facilities, instructional methodology, requirements for certification, course…
29 CFR 1915.501 - General provisions.
Code of Federal Regulations, 2012 CFR
2012-07-01
... safety plan including hazards, controls, fire safety and health rules, and emergency procedures; (ii... (CONTINUED) OCCUPATIONAL SAFETY AND HEALTH STANDARDS FOR SHIPYARD EMPLOYMENT Fire Protection in Shipyard... require employers to protect all employees from fire hazards in shipyard employment, including employees...
29 CFR 1915.501 - General provisions.
Code of Federal Regulations, 2013 CFR
2013-07-01
... safety plan including hazards, controls, fire safety and health rules, and emergency procedures; (ii... (CONTINUED) OCCUPATIONAL SAFETY AND HEALTH STANDARDS FOR SHIPYARD EMPLOYMENT Fire Protection in Shipyard... require employers to protect all employees from fire hazards in shipyard employment, including employees...
29 CFR 1915.501 - General provisions.
Code of Federal Regulations, 2014 CFR
2014-07-01
... safety plan including hazards, controls, fire safety and health rules, and emergency procedures; (ii... (CONTINUED) OCCUPATIONAL SAFETY AND HEALTH STANDARDS FOR SHIPYARD EMPLOYMENT Fire Protection in Shipyard... require employers to protect all employees from fire hazards in shipyard employment, including employees...
CONCEPTUAL DESIGN ASSESSMENT FOR THE CO-FIRING OF BIO-REFINERY SUPPLIED LIGNIN PROJECT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ted Berglund; Jeffrey T. Ranney; Carol L. Babb
2001-10-01
The major aspects of this project are proceeding toward completion. Prior to this quarter, design criteria, tentative site selection, facility layout, and preliminary facility cost estimates were completed and issued. Processing of bio-solids was completed, providing material for the pilot operations. Pilot facility design, equipment selection, and modification were completed during the fourth quarter of 2000. Initial pilot facility shakedown was completed. After some unavoidable delays, a suitable representative supply of MSW feed material was procured. During this first quarter of 2001, shredding of the feed material and final feed conditioning were completed. Pilot facility hydrolysis production was completed tomore » produce lignin for co-fire testing and the lignin fuel was washed and dewatered. Both the lignin and bio-solids fuel materials for co-fire testing were sent to the co-fire facility (EERC) for evaluation and co-firing. EERC has received coal typical of the fuel to the TVA-Colbert boilers. This material will be used at EERC as baseline material and for mixing with the bio-fuel for combustion testing. EERC combustion testing of the bio-based fuels is scheduled to begin in October of 2001. The TVA-Colbert facility has neared completion of the task to evaluate co-location of the Masada facility on the operation of the power generation facility. The TVA-Colbert fossil plant is fully capable of providing a reliable steam supply. The preferred steam supply connection points and steam pipeline routing have been identified. The environmental review of the pipeline routing has been completed and no major impacts have been identified. Detailed assessment of steam export impacts on the Colbert boiler system have been completed and a cost estimate for steam supply system was completed. The cost estimate and the output and heat rate impacts will be used to determine a preliminary price for the exported steam.« less
Resistance of eastern hardwood stems to fire injury and damage
Kevin T. Smith; Elaine Kennedy Sutherland
2006-01-01
This paper reviews the protective features and defensive responses of eastern hardwood species exposed to fire. Trees survive fire through protective features such as thick bark and the induced defenses of compartmentalization. Dissection of trees exposed to prescribed fire in an oak forest in southern Ohio highlights the need to distinguish between bark scorch, stem...
Potential fire behavior in pine flatwood forests following three different fuel reduction techniques
Patrick Brose; Dale Wade
2002-01-01
A computer modeling study to determine the potential fire behavior in pine flatwood forests following three fuel hazard reduction treatments: herbicide, prescribed fire and thinning was conducted in Florida following the 1998 wildfire season. Prescribed fire provided immediate protection but this protection quickly disappeared as the rough recovered. Thinning had a...
10 CFR 503.25 - Public interest.
Code of Federal Regulations, 2010 CFR
2010-01-01
... OF ENERGY (CONTINUED) ALTERNATE FUELS NEW FACILITIES Temporary Exemptions for New Facilities § 503.25..., during the construction of an alternate-fuel fired unit, the petitioner may substitute, in lieu of the... during the construction of an alternate fuel fired unit to be owned or operated by the petitioner; and (2...
Code of Federal Regulations, 2012 CFR
2012-07-01
... latest edition of the NFPA 2001 Standard for Clean Agent Fire Extinguishing Systems, for whichever... requirements. 4—The agent should be recovered from the fire protection system in conjunction with testing or... coverage related to the use of personal protective equipment (e.g., respiratory protection), fire...
Code of Federal Regulations, 2013 CFR
2013-07-01
... latest edition of the NFPA 2001 Standard for Clean Agent Fire Extinguishing Systems, for whichever... requirements. 4—The agent should be recovered from the fire protection system in conjunction with testing or... coverage related to the use of personal protective equipment (e.g., respiratory protection), fire...
Code of Federal Regulations, 2014 CFR
2014-07-01
... latest edition of the NFPA 2001 Standard for Clean Agent Fire Extinguishing Systems, for whichever... requirements. 4—The agent should be recovered from the fire protection system in conjunction with testing or... coverage related to the use of personal protective equipment (e.g., respiratory protection), fire...
Synthesis and evaluation of borates derived from boric acid for fire and decay protections
George Chen
1999-01-01
The degradation of wood by decay, fire and UV constitutes the three major losses of wood products in use. Commercial wood preservatives including chromated copper arsenate(CCA) and pentachlorophenol(penta) can only protect wood from decay. Dual protections of wood against decay and fire or decay and UV if acheivable are more desirable. Many phosphorus and boron...
Laboratory investigation of fire protection coatings for creosote-treated timber railroad bridges
Carol A. Clausen; Robert H. White; James P. Wacker; Stan T. Lebow; Mark A. Dietenberger; Samuel L. Zelinka; Nicole M. Stark
2014-01-01
As the incidence of timber railroad bridge fires increases, so has the need to develop protective measures to reduce the risk from accidental ignitions primarily caused by hot metal objects. Of the six barrier treatments evaluated in the laboratory for their ability to protect timbers from fires sourced with ignition from hot metal objects only one intumescent coating...
Risks and issues in fire safety on the Space Station
NASA Technical Reports Server (NTRS)
Friedman, Robert
1993-01-01
A fire in the inhabited portion of a spacecraft is a greatly feared hazard, but fire protection in space operations is complicated by two factors. First, the spacecraft cabin is an enclosed volume, which limits the resources for fire fighting and the options for crew escape. Second, an orbiting spacecraft experiences a balance of forces, creating a near-zero-gravity (microgravity) environment that profoundly affects the characteristics of fire initiation, spread, and suppression. The current Shuttle Orbiter is protected by a fire-detection and suppression system whose requirements are derived of necessity from accepted terrestrial and aircraft standards. While experience has shown that Shuttle fire safety is adequate, designers recognize that improved systems to respond specifically to microgravity fire characteristics are highly desirable. Innovative technology is particularly advisable for the Space Station, a forthcoming space community with a complex configuration and long-duration orbital missions, in which the effectiveness of current fire-protection systems is unpredictable. The development of risk assessments to evaluate the probabilities and consequences of fire incidents in spacecraft are briefly reviewed. It further discusses the important unresolved issues and needs for improved fire safety in the Space Station, including those of material selection, spacecraft atmospheres, fire detection, fire suppression, and post-fire restoration.
46 CFR 95.17-25 - Additional protection required.
Code of Federal Regulations, 2011 CFR
2011-10-01
... FIRE PROTECTION EQUIPMENT Foam Extinguishing Systems, Details § 95.17-25 Additional protection required. (a) In order that any residual fires above the floor plates may be extinguished when a foam system is...
46 CFR 95.17-25 - Additional protection required.
Code of Federal Regulations, 2010 CFR
2010-10-01
... FIRE PROTECTION EQUIPMENT Foam Extinguishing Systems, Details § 95.17-25 Additional protection required. (a) In order that any residual fires above the floor plates may be extinguished when a foam system is...
Code of Federal Regulations, 2012 CFR
2012-07-01
... from the fire protection system in conjunction with testing or servicing, and recycled for later use or... protective equipment (e.g., respiratory protection), fire protection, hazard communication, worker training...
Code of Federal Regulations, 2013 CFR
2013-07-01
... from the fire protection system in conjunction with testing or servicing, and recycled for later use or... protective equipment (e.g., respiratory protection), fire protection, hazard communication, worker training...
Code of Federal Regulations, 2014 CFR
2014-07-01
... from the fire protection system in conjunction with testing or servicing, and recycled for later use or... protective equipment (e.g., respiratory protection), fire protection, hazard communication, worker training...
Langley Storage facility which houses remains of Apollo 204 craft
NASA Technical Reports Server (NTRS)
1990-01-01
The Apollo 204 command module is seen in storage at Langley Research Center in Virginia. The command module, damaged in the 1967 Apollo fire, its heat shield, booster protective cover and 81 cartons of related hardware and investigative data occupy 3,300 cubic feet of Langley's storage space. Astronauts Virgil I. Grissom, Roger B. Chaffee and Edward H. White II perished in the Apollo 204 spacecraft fire on Jan. 27, 1967 on Launch Complex 34, Cape Canaveral. The hardware has been stored at Langley since 1967. PLEASE NOTE UPDATE: In early May of 1990, NASA announced plans to move the hardware and related data to permanent storage at the site of all the Challenger debris in an abandoned missile silo at Cape Canaveral Air Force Station (CCAFS), Florida. However, at month's end, NASA announced it had decided to keep the capsule at Langley for an indefinite period of time.
Langley Storage facility which houses remains of Apollo 204 craft
NASA Technical Reports Server (NTRS)
1990-01-01
The Apollo 204 command module is seen in storage at Langley Research Center in Virginia. The command module, damaged in the 1967 Apollo fire, its heat shield, booster protective cover and 81 cartons of related hardware and investigative data occupy 3,300 cubic feet of warehouse storage space. Astronauts Virgil I. Grissom, Roger B. Chaffee and Edward H. White II perished in the Apollo 204 spacecraft fire on Jan. 27, 1967 on Launch Complex 34 at Cape Canaveral. The hardware has been stored at Langley since 1967. PLEASE NOTE UPDATE: In early May of 1990, NASA announced plans to move the hardware and related data to permanent storage with the Challenger debris in an abandoned missile silo at Cape Canaveral Air Force Station (CCAFS), Florida. However, at month's end, NASA announced it had decided to keep the capsule at Langley for an indefinite period of time.
Langley Storage facility which houses remains of Apollo 204 craft
NASA Technical Reports Server (NTRS)
1990-01-01
A warehouse holding Apollo 204 hardware and investigative data is seen at Langley Research Center in Virginia. The command module, damaged in the 1967 Apollo fire, its heat shield, booster protective cover and 81 cartons of data and other related materials occupy 3,300 cubic feet. Astronauts Virgil I. Grissom, Roger B. Chaffee and Edward H. White II perished in the Apollo 204 spacecraft fire on Jan. 27, 1967 on Launch Complex 34 at Cape Canaveral. The hardware has been stored at Langley since 1967. PLEASE NOTE UPDATE: In early May of 1990, NASA announced plans to move the hardware and related data to permanent storage with the Challenger debris in an abandoned missile silo at Cape Canaveral Air Force Station (CCAFS), Florida. However, at month's end, NASA announced it had decided to keep the capsule at Langley for an indefinite period of time.
Langley Storage facility which houses remains of Apollo 204 craft
NASA Technical Reports Server (NTRS)
1990-01-01
Part of 81 cartons of Apollo 204 hardware and investigation data are seen in storage at Langley Research Center in Virginia. The command module, damaged in the 1967 Apollo fire, its heat shield, booster protective cover and the cartons occupy 3,300 cubic feet of Langley's storage space. Astronauts Virgil I. Grissom, Roger B. Chaffee and Edward H. White II perished in the Apollo 204 spacecraft fire on Jan. 27, 1967 on Launch Complex 34, Cape Canaveral. The hardware has been stored at Langley since 1967. PLEASE NOTE UPDATE: In early May of 1990, NASA announced plans to move the hardware and related data to permanent storage with the Challenger debris in an abandoned missile silo at Cape Canaveral Air Force Station (CCAFS), Florida. However, at month's end, NASA announced it had decided to keep the capsule at Langley for an indefinite period of time.
Waste Technology Engineering Laboratory (324 building)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kammenzind, D.E.
The 324 Facility Standards/Requirements Identification Document (S/RID) is comprised of twenty functional areas. Two of the twenty functional areas (Decontamination and Decommissioning and Environmental Restoration) were determined as nonapplicable functional areas and one functional area (Research and Development and Experimental Activities) was determined applicable, however, requirements are found in other functional areas and will not be duplicated. Each functional area follows as a separate chapter, either containing the S/RID or a justification for nonapplicability. The twenty functional areas listed below follow as chapters: 1. Management Systems; 2. Quality Assurance; 3. Configuration Management; 4. Training and Qualification; 5. Emergency Management; 6.more » Safeguards and Security; 7. Engineering Program; 8. Construction; 9. Operations; 10. Maintenance; 11. Radiation Protection; 12. Fire Protection; 13. Packaging and Transportation; 14. Environmental Restoration; 15. Decontamination and Decommissioning; 16. Waste Management; 17. Research and Development and Experimental Activities; 18. Nuclear Safety; 19. Occupational Safety and Health; 20. Environmental Protection.« less
2013 R&D 100 Award: 'SHIELD' protects NIF optics from harmful pulses
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chou, Jason
In the past, it took as long as 12 hours to manually screen 48 critical checkpoints at the National Ignition Facility (NIF) for harmful laser pulses. The screening equipment had to be moved from point to point throughout a facility the size of three football fields. Now with a new technology, called Laser SHIELD (Screening at High-throughput to Identify Energetic Laser Distortion), and with the push of a button, the screening can be done in less than one second. Proper screening of pulses is critical for the operation of high-energy lasers to ensure that the laser does not exceed safemore » operating conditions for optics. The energetic beams of light are so powerful that, when left uncontrolled, they can shatter the extremely valuable glass inside the laser. If a harmful pulse is found, immediate adjustments can be made in order to protect the optics for the facility. Laser SHIELD is a custom-designed high-throughput screening system built from low-cost and commercially available components found in the telecommunications industry. Its all-fiber design makes it amenable to the unique needs of high-energy laser facilities, including routing to intricate pick-off locations, immunity to electromagnetic interference and low-loss transport (up to several kilometers). The technology offers several important benefits for NIF. First, the facility is able to fire more shots in less time-an efficiency that saves the facility millions of dollars each year. Second, high-energy lasers are more flexible to wavelength changes requested by target physicists. Third, by identifying harmful pulses before they damage the laser's optics, the facility potentially saves hundreds of thousands of dollars in maintenance costs each year.« less
2013 R&D 100 Award: 'SHIELD' protects NIF optics from harmful pulses
Chou, Jason
2018-02-13
In the past, it took as long as 12 hours to manually screen 48 critical checkpoints at the National Ignition Facility (NIF) for harmful laser pulses. The screening equipment had to be moved from point to point throughout a facility the size of three football fields. Now with a new technology, called Laser SHIELD (Screening at High-throughput to Identify Energetic Laser Distortion), and with the push of a button, the screening can be done in less than one second. Proper screening of pulses is critical for the operation of high-energy lasers to ensure that the laser does not exceed safe operating conditions for optics. The energetic beams of light are so powerful that, when left uncontrolled, they can shatter the extremely valuable glass inside the laser. If a harmful pulse is found, immediate adjustments can be made in order to protect the optics for the facility. Laser SHIELD is a custom-designed high-throughput screening system built from low-cost and commercially available components found in the telecommunications industry. Its all-fiber design makes it amenable to the unique needs of high-energy laser facilities, including routing to intricate pick-off locations, immunity to electromagnetic interference and low-loss transport (up to several kilometers). The technology offers several important benefits for NIF. First, the facility is able to fire more shots in less time-an efficiency that saves the facility millions of dollars each year. Second, high-energy lasers are more flexible to wavelength changes requested by target physicists. Third, by identifying harmful pulses before they damage the laser's optics, the facility potentially saves hundreds of thousands of dollars in maintenance costs each year.
ERIC Educational Resources Information Center
Walker, Bonnie
Three booklets provide fire safety information for staff of residential facilities serving people with developmental disabilities. Booklets focus on: (1) preventing fire death and injury, (2) conducting a fire drill in a group home, and (3) the role of fire safety experts. The first booklet stresses the elimination of the following dangers:…
Development of a Midscale Test for Flame Resistant Protection
2016-08-01
Evaluation of Flame Resistant Clothing for Protection against Fire Simulations Using an Instrumented Manikin, which provides both radiant and convective heat...TEST METHODS FIRE RESISTANT MATERIALS TORCHES SIMULATION TEST EQUIPMENT FLAME RESISTANT CLOTHING PERFORMANCE(ENGINEERING... fabric during a fire , and even after the fire has been extinguished. The best known full scale transmitted heat flux test is the "ASTM F1930
Code of Federal Regulations, 2012 CFR
2012-01-01
... leased buildings exempt from State and local code requirements in fire protection? 102-80.85 Section 102... Fire Prevention State and Local Codes § 102-80.85 Are Federally owned and leased buildings exempt from State and local code requirements in fire protection? Federally owned buildings are generally exempt...
Code of Federal Regulations, 2013 CFR
2013-07-01
... leased buildings exempt from State and local code requirements in fire protection? 102-80.85 Section 102... Fire Prevention State and Local Codes § 102-80.85 Are Federally owned and leased buildings exempt from State and local code requirements in fire protection? Federally owned buildings are generally exempt...
Code of Federal Regulations, 2014 CFR
2014-01-01
... leased buildings exempt from State and local code requirements in fire protection? 102-80.85 Section 102... Fire Prevention State and Local Codes § 102-80.85 Are Federally owned and leased buildings exempt from State and local code requirements in fire protection? Federally owned buildings are generally exempt...
Code of Federal Regulations, 2011 CFR
2011-01-01
... leased buildings exempt from State and local code requirements in fire protection? 102-80.85 Section 102... Fire Prevention State and Local Codes § 102-80.85 Are Federally owned and leased buildings exempt from State and local code requirements in fire protection? Federally owned buildings are generally exempt...
Code of Federal Regulations, 2010 CFR
2010-07-01
... leased buildings exempt from State and local code requirements in fire protection? 102-80.85 Section 102... Fire Prevention State and Local Codes § 102-80.85 Are Federally owned and leased buildings exempt from State and local code requirements in fire protection? Federally owned buildings are generally exempt...
LA-UR-14-27684, Analysis of Wildland Fire Hazard to the TWF at Los Alamos National Labs
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gilbertson, Sarah
Wildfires represent an Anticipated Natural Phenomena Hazard for LANL and the surrounding area. The TWF facility is located in a cleared area and is surrounded on three sides by roadway pavement. Therefore, direct propagation of flames to the facility is not considered the most credible means of ignition. Rather, fires started by airborne transport of burning brands constitute the most significant wildland fire threat to the TWF. The purpose of this document is to update LA-UR-13-24529, Airborne Projection of Burning Embers – Planning and Controls for Los Alamos National Laboratory Facilities, to be specific to the TWF site and operations.
10 CFR 50.48 - Fire protection.
Code of Federal Regulations, 2011 CFR
2011-01-01
... suppression systems; and (iii) The means to limit fire damage to structures, systems, or components important...) Standard 805, “Performance-Based Standard for Fire Protection for Light Water Reactor Electric Generating... pressurized-water reactors (PWRs) is not permitted. (iv) Uncertainty analysis. An uncertainty analysis...
10 CFR 50.48 - Fire protection.
Code of Federal Regulations, 2010 CFR
2010-01-01
... suppression systems; and (iii) The means to limit fire damage to structures, systems, or components important...) Standard 805, “Performance-Based Standard for Fire Protection for Light Water Reactor Electric Generating... pressurized-water reactors (PWRs) is not permitted. (iv) Uncertainty analysis. An uncertainty analysis...
Feasibility of a small central cogenerated energy facility: Energy management memorandum
NASA Astrophysics Data System (ADS)
Porter, R. N.
1982-10-01
The thermal economic feasibility of a small cogenerated energy facility designed to serve several industries in the Stockyards area was investigated. Cogeneration options included two dual fuel diesels and two gas turbines, all with waste heat boilers, and five fired boilers. Fuels included natural gas, and for the fired boiler cases, also low sulphur coal and municipal refuse. For coal and refuse, the option of steam only without cogeneration was also assessed. The fired boiler cogeneration systems employed back pressure steam turbines. The refuse fired cases utilized electrical capacities, 8500 to 52,400 lbm/hr and 0 to 9.9 MW (e), respectively. Deficient steam was assumed generated independently in existing equipment. Excess electrical power over that which was displaced was sold to Commonwealth Edison Company under PURPA (Public Utility Regulatory Policies Act). The facility was operated by a mutually owned corporation formed by the cogenerated power users.
Risk reduction in road and rail LPG transportation by passive fire protection.
Paltrinieri, Nicola; Landucci, Gabriele; Molag, Menso; Bonvicini, Sarah; Spadoni, Gigliola; Cozzani, Valerio
2009-08-15
The potential reduction of risk in LPG (Liquefied Petroleum Gas) road transport due to the adoption of passive fire protections was investigated. Experimental data available for small scale vessels fully engulfed by a fire were extended to real scale road and rail tankers through a finite elements model. The results of mathematical simulations of real scale fire engulfment scenarios that may follow accidents involving LPG tankers proved the effectiveness of the thermal protections in preventing the "fired" BLEVE (Boiling Liquid Expanding Vapour Explosion) scenario. The presence of a thermal coating greatly increases the "time to failure", providing a time lapse that in the European experience may be considered sufficient to allow the start of effective mitigation actions by fire brigades. The results obtained were used to calculate the expected reduction of individual and societal risk due to LPG transportation in real case scenarios. The analysis confirmed that the introduction of passive fire protections turns out in a significant reduction of risk, up to an order of magnitude in the case of individual risk and of about 50% if the expectation value is considered. Thus, the adoption of passive fire protections, not compulsory in European regulations, may be an effective technical measure for risk reduction, and may contribute to achieve the control of "major accidents hazards" cited by the European legislation.
NASA Technical Reports Server (NTRS)
1997-01-01
Advanced Flexible Reusable Surface Insulation, developed by Ames Research Center, protects the Space Shuttle from the searing heat that engulfs it on reentry into the Earth's atmosphere. Initially integrated into the Space Shuttle by Rockwell International, production was transferred to Hi-Temp Insulation Inc. in 1974. Over the years, Hi-Temp has created many new technologies to meet the requirements of the Space Shuttle program. This expertise is also used commercially, including insulation blankets to cover aircrafts parts, fire barrier material to protect aircraft engine cowlings and aircraft rescue fire fighter suits. A Fire Protection Division has also been established, offering the first suit designed exclusively by and for aircraft rescue fire fighters. Hi-Temp is a supplier to the Los Angeles City Fire Department as well as other major U.S. civil and military fire departments.
Spinoff from a Mooncraft Technology
NASA Technical Reports Server (NTRS)
1988-01-01
Avco Specialty Materials' Chartek III fireproofing provides longterm fire protection for structural steel in high risk industrial applications such as structural conduits, pipes and valves of offshore platforms, and storage tanks used in hydrocarbon processing industry. In the presence of fire, Chartek III fire-proofing provides two kinds of protection. One of them is ablation, technique used on Apollo involving dissipation of heat by burnoff. The other is called intumescence or swelling. Heat causes the Chartek coating to swell to a thickness six times greater than when it was applied forming a protective blanket of char that retards transfer of heat to the steel structure. Mesh reinforcement keeps the char intact and reduces metal fatigue. Chartek provides fire protection for as much as two or three hours depending on the type of fire and the thickness of the coating applied.
75 FR 17641 - Updating Fire Safety Standards
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-07
... DEPARTMENT OF VETERANS AFFAIRS 38 CFR Parts 17 and 59 RIN 2900-AN57 Updating Fire Safety Standards... for VA approval of such facilities, including standards for fire safety and heating and cooling... submitted in response to ``RIN 2900-AN57--Updating Fire Safety Standards.'' Copies of comments received will...
Atmospheric Science Data Center
2013-01-23
FIRE III ACE Data Sets The First International Satellite Cloud ... Regional Experiment (FIRE) - Arctic Cloud Experiment (ACE) was conducted April through July of 1998. It was held in conjunction with ... Heat Budget of the Arctic Ocean (SHEBA) Experiment. The FIRE-ACE focused on all aspects of Arctic cloud systems. The main facility was ...
Multi-hazards risk assessment at different levels
NASA Astrophysics Data System (ADS)
Frolova, N.; Larionov, V.; Bonnin, J.
2012-04-01
Natural and technological disasters are becoming more frequent and devastating. Social and economic losses due to those events increase annually, which is definitely in relation with evolution of society. Natural hazards identification and analysis, as well natural risk assessment taking into account secondary technological accidents are the first steps in prevention strategy aimed at saving lives and protecting property against future events. The paper addresses methodological issues of natural and technological integrated risk assessment and mapping at different levels [1, 2]. At the country level the most hazardous natural processes, which may results in fatalities, injuries and economic loss in the Russian Federation, are considered. They are earthquakes, landslides, mud flows, floods, storms, avalanches. The special GIS environment for the country territory was developed which includes information about hazards' level and reoccurrence, an impact databases for the last 20 years, as well as models for estimating damage and casualties caused by these hazards. Federal maps of seismic individual and collective risk, as well as multi-hazards natural risk maps are presented. The examples of regional seismic risk assessment taking into account secondary accidents at fire, explosion and chemical hazardous facilities and regional integrated risk assessment are given for the earthquake prone areas of the Russian Federation. The paper also gives examples of loss computations due to scenario earthquakes taking into account accidents trigged by strong events at critical facilities: fire and chemical hazardous facilities, including oil pipe lines routes located in the earthquake prone areas. The estimations of individual seismic risk obtained are used by EMERCOM of the Russian Federation, as well as by other federal and local authorities, for planning and implementing preventive measures, aimed at saving lives and protecting property against future disastrous events. The results also allow to develop effective emergency response plans taking into account possible scenario events. Taking into consideration the size of the oil pipe line systems located in the highly active seismic zones, the results of seismic risk computation are used by TRANSNEFT JSC.
Alternative approach for fire suppression of class A, B and C fires in gloveboxes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rosenberger, Mark S; Tsiagkouris, James A
2011-02-10
Department of Energy (DOE) Orders and National Fire Protection Association (NFPA) Codes and Standards require fire suppression in gloveboxes. Several potential solutions have been and are currently being considered at Los Alamos National Laboratory (LANL). The objective is to provide reliable, minimally invasive, and seismically robust fire suppression capable of extinguishing Class A, B, and C fires; achieve compliance with DOE and NFPA requirements; and provide value-added improvements to fire safety in gloveboxes. This report provides a brief summary of current approaches and also documents the successful fire tests conducted to prove that one approach, specifically Fire Foe{trademark} tubes, ismore » capable of achieving the requirement to provide reliable fire protection in gloveboxes in a cost-effective manner.« less
Fire weather in western Oregon and western Washington in 1952 compared with other years.
Owen P. Cramer
1953-01-01
How did the potential burning conditions of the 1952 fire season compare with those of previous years? The answer is important to those who protect forests from fire. Knowing the relative severity of the burning conditions will help them judge the effectiveness of their fire protection programs. This paper reports ratings of the weather factors most closely related to...
Validation and Verification (V and V) Testing on Midscale Flame Resistant (FR) Test Method
2016-12-16
Method for Evaluation of Flame Resistant Clothing for Protection against Fire Simulations Using an Instrumented Manikin. Validation and...complement (not replace) the capabilities of the ASTM F1930 Standard Test Method for Evaluation of Flame Resistant Clothing for Protection against Fire ...Engineering Center (NSRDEC) to complement the ASTM F1930 Standard Test Method for Evaluation of Flame Resistant Clothing for Protection against Fire
29 CFR 1915.509 - Definitions applicable to this subpart.
Code of Federal Regulations, 2010 CFR
2010-07-01
... harmful. Hose systems—fire protection systems consisting of a water supply, approved fire hose, and a... fire protection system consisting of piping and hose connections used to supply water to approved hose... influence shipyard employment (such as mail delivery or office supply services). Dangerous atmosphere—an...
49 CFR 176.315 - Fire protection requirements.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Detailed Requirements for Class 3 (Flammable) and Combustible Liquid Materials § 176.315 Fire protection... (flammable) or combustible liquid for which it is required. Each fire extinguisher must be accessible to the... (flammable) and combustible liquids stowage areas must be fitted with an approved combination solid stream...
Fire Protection. Honeywell Planning Guide.
ERIC Educational Resources Information Center
Honeywell, Inc., Minneapolis, Minn.
A general discussion of fire alarms and protection is provided by a manufacturer of automated monitoring and control systems. Background information describes old and new fire alarm systems, comparing system components, wage savings, and cost analysis. Different kinds of automatic systems are listed, including--(1) local system, (2) auxiliary…
The Missoula Fire Sciences Laboratory: A 50-year dedication to understanding wildlands and fire
Diane M. Smith
2012-01-01
In 1960, the USDA Forest Service established the Northern Forest Fire Laboratory (now the Missoula Fire Sciences Laboratory) to find scientific solutions for better managing the nation's wildland resources and to research ways to improve forest fire prevention and suppression. This new state-of-the-art research facility did not emerge from a vacuum, however. This...
NASA Technical Reports Server (NTRS)
Struzenberg, L. L.; West, J. S.
2011-01-01
This paper describes the use of targeted Loci/CHEM CFD simulations to evaluate the effects of a dual-engine first-stage hot-fire test on an evolving integrated launch pad/test article design. This effort was undertaken as a part of the NESC Independent Assessment of the Taurus II Stage Test Series. The underlying conceptual model included development of a series of computational models and simulations to analyze the plume induced environments on the pad, facility structures and test article. A pathfinder simulation was first developed, capable of providing quick-turn around evaluation of plume impingement pressures on the flame deflector. Results from this simulation were available in time to provide data for an ongoing structural assessment of the deflector. The resulting recommendation was available in a timely manner and was incorporated into construction schedule for the new launch stand under construction at Wallops Flight Facility. A series of Reynolds-Averaged Navier-Stokes (RANS) quasi-steady simulations representative of various key elements of the test profile was performed to identify potential concerns with the test configuration and test profile. As required, unsteady Hybrid-RANS/LES simulations were performed, to provide additional insight into critical aspects of the test sequence. Modifications to the test-specific hardware and facility structures thermal protection as well as modifications to the planned hot-fire test profile were implemented based on these simulation results.
Division of Forestry Fire and Aviation Program
Conservation Education Timber Management Wildland Fire & Aviation Burn Permits Firewise Alaska Brochure (PDF) Fire Management Plans Fire Assignments Annual Fire Statistics Fire Terms Glossary Incident Business Management Grants Become an Alaska Firewise Community Community Wildland Fire Protection Plans
ERIC Educational Resources Information Center
Campbell, Clifton P.; Buchanan, Joseph P.
1977-01-01
Fire emergency preparedness measures to take to prevent school fires and to protect against injury and minimize damage when fire does occur are presented. Includes fire safety practices, extinguishers for different classes of fires and their use, and the need for fire safety training in schools. (MF)
A Combined Water-Bromotrifluoromethane Crash-Fire Protection System for a T-56 Turbopropeller Engine
NASA Technical Reports Server (NTRS)
Campbell, John A.; Busch, Arthur M.
1959-01-01
A crash-fire protection system is described which will suppress the ignition of crash-spilled fuel that may be ingested by a T-56 turbo-propeller engine. This system includes means for rapidly extinguishing the combustor flame, means for cooling and inerting with water the hot engine parts likely to ignite engine ingested fuel, and means for blanketing with bromotrifluoromethane massive metal parts that may reheat after the engine stops rotating. Combustion-chamber flames were rapidly extinguished at the engine fuel nozzles by a fuel shutoff and drain valve. Hot engine parts were inerted and cooled by 42 pounds of water discharged at seven engine stations. Massive metal parts that could reheat were inerted with 10 pounds of bromotrifluoromethane discharged at two engine stations. Performance trials of the crash-fire protection system were conducted by bringing the engine up to takeoff temperature, actuating the crash-fire protection system, and then spraying fuel into the engine to simulate crash-ingested fuel. No fires occurred during these trials, although fuel was sprayed into the engine from 0.3 second to 15 minutes after actuating the crash-fire protection system.
29 CFR 1926.150 - Fire protection.
Code of Federal Regulations, 2014 CFR
2014-07-01
.... Modification of sprinkler systems to permit alterations or additional demolition should be expedited so that... each floor. (e) Fire alarm devices. (1) An alarm system, e.g., telephone system, siren, etc., shall be... 29 Labor 8 2014-07-01 2014-07-01 false Fire protection. 1926.150 Section 1926.150 Labor...
46 CFR 76.01-2 - Incorporation by reference.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Sprinkler Systems (“NFPA 13”)—76.25-1, 76.25-90. (d) Underwriters Laboratories Inc. (UL), 12 Laboratory... Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION... Connections for Marine Fire Applications (“ASTM F 1121”)—76.10-10. (c) National Fire Protection Association...
29 CFR 1926.150 - Fire protection.
Code of Federal Regulations, 2011 CFR
2011-07-01
.... Modification of sprinkler systems to permit alterations or additional demolition should be expedited so that... each floor. (e) Fire alarm devices. (1) An alarm system, e.g., telephone system, siren, etc., shall be... 29 Labor 8 2011-07-01 2011-07-01 false Fire protection. 1926.150 Section 1926.150 Labor...
29 CFR 1926.150 - Fire protection.
Code of Federal Regulations, 2013 CFR
2013-07-01
.... Modification of sprinkler systems to permit alterations or additional demolition should be expedited so that... each floor. (e) Fire alarm devices. (1) An alarm system, e.g., telephone system, siren, etc., shall be... 29 Labor 8 2013-07-01 2013-07-01 false Fire protection. 1926.150 Section 1926.150 Labor...
46 CFR 76.01-2 - Incorporation by reference.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Sprinkler Systems (“NFPA 13”)—76.25-1, 76.25-90. (d) Underwriters Laboratories Inc. (UL), 12 Laboratory... Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION... Connections for Marine Fire Applications (“ASTM F 1121”)—76.10-10. (c) National Fire Protection Association...
29 CFR 1926.150 - Fire protection.
Code of Federal Regulations, 2012 CFR
2012-07-01
.... Modification of sprinkler systems to permit alterations or additional demolition should be expedited so that... each floor. (e) Fire alarm devices. (1) An alarm system, e.g., telephone system, siren, etc., shall be... 29 Labor 8 2012-07-01 2012-07-01 false Fire protection. 1926.150 Section 1926.150 Labor...
The economic dimension of wildland fires
Armando Gonzalez-Caban
2013-01-01
The economic relevance of wildland fire management and protection programs is ever growing, particularly considering mounting wildfire costs and losses globally, and the justifications required for budget allocations to management and protection of forest ecosystems. However, there are major difficulties in grappling with the problem of rapidly increasing wildland fire...
46 CFR 76.01-2 - Incorporation by reference.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 3 2010-10-01 2010-10-01 false Incorporation by reference. 76.01-2 Section 76.01-2 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION... Connections for Marine Fire Applications (“ASTM F 1121”)—76.10-10. (c) National Fire Protection Association...
Wildlife conservation and solar energy development in the Desert Southwest, United States
Lovich, Jeffrey E.; Ennen, Josua R.
2011-01-01
Large areas of public land are currently being permitted or evaluated for utility-scale solar energy development (USSED) in the southwestern United States, including areas with high biodiversity and protected species. However, peer-reviewed studies of the effects of USSED on wildlife are lacking. The potential effects of the construction and the eventual decommissioning of solar energy facilities include the direct mortality of wildlife; environmental impacts of fugitive dust and dust suppressants; destruction and modification of habitat, including the impacts of roads; and off-site impacts related to construction material acquisition, processing, and transportation. The potential effects of the operation and maintenance of the facilities include habitat fragmentation and barriers to gene flow, increased noise, electromagnetic field generation, microclimate alteration, pollution, water consumption, and fire. Facility design effects, the efficacy of site-selection criteria, and the cumulative effects of USSED on regional wildlife populations are unknown. Currently available peer-reviewed data are insufficient to allow a rigorous assessment of the impact of USSED on wildlife.
NASA Astrophysics Data System (ADS)
1982-09-01
The complete Barstow Solar Pilot Plant is described. The plant requirements and general description are presented, the mechanical, electric power, and control and instrumentation systems as well as civil engineering and structural aspects and the station buildings are described. Included in the mechanical systems are the heliostats, receiver, thermal storage system, beam characterization system, steam, water, nitrogen, and compressed air systems, chemical feed system, fire protection system, drains, sumps and the waste disposal systems, and heating, ventilating, and air conditioning systems.
Atmospheric Science Data Center
2014-03-18
... Regional Experiment (FIRE) - Arctic Cloud Experiment (ACE) was conducted April through July of 1998. It was held in conjunction with ... Heat Budget of the Arctic Ocean (SHEBA) Experiment. The FIRE-ACE focused on all aspects of Arctic cloud systems. The main facility was ...
Solution of Fire Protection in Historic Buildings
NASA Astrophysics Data System (ADS)
Iringová, Agnes; Idunk, Róbert
2016-12-01
The paper introduces optimization of the functional use of renovated spaces in historic buildings in terms of fire risk. It brings assessment of fire protection in the folk house Habánsky Dvor, situated in the village of Veľké Leváre, whose function was changed into the museum. It goes into static analysis of existing load-bearing structures and assessment of their fire resistance according to Eurocodes.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false Can the water supply for the helicopter deck fire protection system be part of a fire water system? 149.419 Section 149.419 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: DESIGN, CONSTRUCTION, AND EQUIPMENT...
Code of Federal Regulations, 2012 CFR
2012-07-01
... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false Can the water supply for the helicopter deck fire protection system be part of a fire water system? 149.419 Section 149.419 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: DESIGN, CONSTRUCTION, AND EQUIPMENT...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Can the water supply for the helicopter deck fire protection system be part of a fire water system? 149.419 Section 149.419 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: DESIGN, CONSTRUCTION, AND EQUIPMENT...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false Can the water supply for the helicopter deck fire protection system be part of a fire water system? 149.419 Section 149.419 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: DESIGN, CONSTRUCTION, AND EQUIPMENT...
Conservation Education Timber Management Wildland Fire & Aviation Burn Permits Firewise Alaska Brochure (PDF) Fire Management Plans Fire Assignments Annual Fire Statistics Fire Terms Glossary Incident Business Management Grants Become an Alaska Firewise Community Community Wildland Fire Protection Plans
Code of Federal Regulations, 2010 CFR
2010-07-01
... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Fires. 127.615 Section 127.615... Facilities Handling Liquefied Natural Gas Firefighting § 127.615 Fires. In the marine transfer area for LNG, the operator shall ensure that there are no fires when there is LNG present. [CGD 78-038, 53 FR 3376...
NASA Technical Reports Server (NTRS)
1981-01-01
The reference conceptual design of the magnetohydrodynamic (MHD) Engineering Test Facility (ETF), a prototype 200 MWe coal-fired electric generating plant designed to demonstrate the commercial feasibility of open cycle MHD, is summarized. Main elements of the design, systems, and plant facilities are illustrated. System design descriptions are included for closed cycle cooling water, industrial gas systems, fuel oil, boiler flue gas, coal management, seed management, slag management, plant industrial waste, fire service water, oxidant supply, MHD power ventilating
NASA Astrophysics Data System (ADS)
1981-09-01
The reference conceptual design of the magnetohydrodynamic (MHD) Engineering Test Facility (ETF), a prototype 200 MWe coal-fired electric generating plant designed to demonstrate the commercial feasibility of open cycle MHD, is summarized. Main elements of the design, systems, and plant facilities are illustrated. System design descriptions are included for closed cycle cooling water, industrial gas systems, fuel oil, boiler flue gas, coal management, seed management, slag management, plant industrial waste, fire service water, oxidant supply, MHD power ventilating
Fire safety practices in the Shuttle and the Space Station Freedom
NASA Technical Reports Server (NTRS)
Friedman, Robert
1993-01-01
The Shuttle reinforces its policy of fire-preventive measures with onboard smoke detectors and Halon 1301 fire extinguishers. The forthcoming Space Station Freedom will have expanded fire protection with photoelectric smoke detectors, radiation flame detectors, and both fixed and portable carbon dioxide fire extinguishers. Many design and operational issues remain to be resolved for Freedom. In particular, the fire-suppression designs must consider the problems of gas leakage in toxic concentrations, alternative systems for single-failure redundancy, and commonality with the corresponding systems of the Freedom international partners. While physical and engineering requirements remain the primary driving forces for spacecraft fire-safety technology, there are, nevertheless, needs and opportunities for the application of microgravity combustion knowledge to improve and optimize the fire-protective systems.