Sample records for facility personnel monitoring

  1. Personnel reliability impact on petrochemical facilities monitoring system's failure skipping probability

    NASA Astrophysics Data System (ADS)

    Kostyukov, V. N.; Naumenko, A. P.

    2017-08-01

    The paper dwells upon urgent issues of evaluating impact of actions conducted by complex technological systems operators on their safe operation considering application of condition monitoring systems for elements and sub-systems of petrochemical production facilities. The main task for the research is to distinguish factors and criteria of monitoring system properties description, which would allow to evaluate impact of errors made by personnel on operation of real-time condition monitoring and diagnostic systems for machinery of petrochemical facilities, and find and objective criteria for monitoring system class, considering a human factor. On the basis of real-time condition monitoring concepts of sudden failure skipping risk, static and dynamic error, monitoring systems, one may solve a task of evaluation of impact that personnel's qualification has on monitoring system operation in terms of error in personnel or operators' actions while receiving information from monitoring systems and operating a technological system. Operator is considered as a part of the technological system. Although, personnel's behavior is usually a combination of the following parameters: input signal - information perceiving, reaction - decision making, response - decision implementing. Based on several researches on behavior of nuclear powers station operators in USA, Italy and other countries, as well as on researches conducted by Russian scientists, required data on operator's reliability were selected for analysis of operator's behavior at technological facilities diagnostics and monitoring systems. The calculations revealed that for the monitoring system selected as an example, the failure skipping risk for the set values of static (less than 0.01) and dynamic (less than 0.001) errors considering all related factors of data on reliability of information perception, decision-making, and reaction fulfilled is 0.037, in case when all the facilities and error probability are under

  2. Developing the Rehabilitation Facility Personnel Manual.

    ERIC Educational Resources Information Center

    Gilbertson, Alan D.

    This guide is intended to provide rehabilitation facilities with assistance in developing or improving their facility personnel manual, along with examples of what some rehabilitation facilities are including within their personnel manuals. The introduction to the guide discusses how a facility can begin the formulation of its personnel manual.…

  3. 10 CFR 34.47 - Personnel monitoring.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Personnel monitoring. 34.47 Section 34.47 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Radiation Safety Requirements § 34.47 Personnel monitoring. (a) The licensee may not...

  4. 10 CFR 34.47 - Personnel monitoring.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Personnel monitoring. 34.47 Section 34.47 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Radiation Safety Requirements § 34.47 Personnel monitoring. (a) The licensee may not...

  5. 10 CFR 34.47 - Personnel monitoring.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 1 2014-01-01 2014-01-01 false Personnel monitoring. 34.47 Section 34.47 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Radiation Safety Requirements § 34.47 Personnel monitoring. (a) The licensee may not...

  6. 10 CFR 34.47 - Personnel monitoring.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 1 2012-01-01 2012-01-01 false Personnel monitoring. 34.47 Section 34.47 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Radiation Safety Requirements § 34.47 Personnel monitoring. (a) The licensee may not...

  7. 10 CFR 34.47 - Personnel monitoring.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 1 2013-01-01 2013-01-01 false Personnel monitoring. 34.47 Section 34.47 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Radiation Safety Requirements § 34.47 Personnel monitoring. (a) The licensee may not...

  8. 10 CFR 39.65 - Personnel monitoring.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 1 2014-01-01 2014-01-01 false Personnel monitoring. 39.65 Section 39.65 Energy NUCLEAR REGULATORY COMMISSION LICENSES AND RADIATION SAFETY REQUIREMENTS FOR WELL LOGGING Radiation Safety Requirements § 39.65 Personnel monitoring. (a) The licensee may not permit an individual to act as a logging...

  9. 10 CFR 39.65 - Personnel monitoring.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Personnel monitoring. 39.65 Section 39.65 Energy NUCLEAR REGULATORY COMMISSION LICENSES AND RADIATION SAFETY REQUIREMENTS FOR WELL LOGGING Radiation Safety Requirements § 39.65 Personnel monitoring. (a) The licensee may not permit an individual to act as a logging...

  10. 10 CFR 39.65 - Personnel monitoring.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 1 2013-01-01 2013-01-01 false Personnel monitoring. 39.65 Section 39.65 Energy NUCLEAR REGULATORY COMMISSION LICENSES AND RADIATION SAFETY REQUIREMENTS FOR WELL LOGGING Radiation Safety Requirements § 39.65 Personnel monitoring. (a) The licensee may not permit an individual to act as a logging...

  11. 10 CFR 39.65 - Personnel monitoring.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Personnel monitoring. 39.65 Section 39.65 Energy NUCLEAR REGULATORY COMMISSION LICENSES AND RADIATION SAFETY REQUIREMENTS FOR WELL LOGGING Radiation Safety Requirements § 39.65 Personnel monitoring. (a) The licensee may not permit an individual to act as a logging...

  12. 10 CFR 39.65 - Personnel monitoring.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 1 2012-01-01 2012-01-01 false Personnel monitoring. 39.65 Section 39.65 Energy NUCLEAR REGULATORY COMMISSION LICENSES AND RADIATION SAFETY REQUIREMENTS FOR WELL LOGGING Radiation Safety Requirements § 39.65 Personnel monitoring. (a) The licensee may not permit an individual to act as a logging...

  13. 14 CFR 141.89 - Maintenance of personnel, facilities, and equipment.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Maintenance of personnel, facilities, and... Maintenance of personnel, facilities, and equipment. The holder of a pilot school certificate or provisional... training unless: (a) Each airport, aircraft, and facility necessary for that training meets the standards...

  14. 14 CFR 141.89 - Maintenance of personnel, facilities, and equipment.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Maintenance of personnel, facilities, and... Maintenance of personnel, facilities, and equipment. The holder of a pilot school certificate or provisional... training unless: (a) Each airport, aircraft, and facility necessary for that training meets the standards...

  15. 14 CFR 141.89 - Maintenance of personnel, facilities, and equipment.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Maintenance of personnel, facilities, and... Maintenance of personnel, facilities, and equipment. The holder of a pilot school certificate or provisional... training unless: (a) Each airport, aircraft, and facility necessary for that training meets the standards...

  16. 14 CFR 141.89 - Maintenance of personnel, facilities, and equipment.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Maintenance of personnel, facilities, and... Maintenance of personnel, facilities, and equipment. The holder of a pilot school certificate or provisional... training unless: (a) Each airport, aircraft, and facility necessary for that training meets the standards...

  17. 14 CFR 141.89 - Maintenance of personnel, facilities, and equipment.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Maintenance of personnel, facilities, and... Maintenance of personnel, facilities, and equipment. The holder of a pilot school certificate or provisional... training unless: (a) Each airport, aircraft, and facility necessary for that training meets the standards...

  18. [Current state and prospects of military personnel health monitoring].

    PubMed

    Rezvantsev, M V; Kuznetsov, S M; Ivanov, V V; Zakurdaev, V V

    2014-01-01

    The current article is dedicated to some features of the Russian Federation Armed Forces military personnel health monitoring such as legal and informational provision, methodological basis of functioning, historical aspect of formation and development of the social and hygienic monitoring in the Russian Federation Armed Forces. The term "military personnel health monitoring" is defined as an analytical system of constant and long-term observation, analysis, assessment, studying of factors determined the military personnel health, these factors correlations, health risk factors management in order to minimize them. The current state of the military personnel health monitoring allows coming to the conclusion that the military health system does have forces and resources for state policy of establishing the population health monitoring system implementation. The following directions of the militarily personnel health monitoring improvement are proposed: the Russian Federation Armed Forces medical service record and report system reorganization bringing it closer to the civilian one, implementation of the integrated approach to the medical service informatisation, namely, military personnel health status and medical service resources monitoring. The leading means in this direction are development and introduction of a military serviceman individual health status monitoring system on the basis of a serviceman electronic medical record card. Also it is proposed the current Russian Federation Armed Forces social and hygienic monitoring improvement at the expense of informational interaction between the two subsystems on the basis of unified military medical service space.

  19. Military Personnel: Enhanced Collaboration and Process Improvements Needed for Determining Military Treatment Facility Medical Personnel Requirements

    DTIC Science & Technology

    2010-07-01

    Department of Defense (DOD) are in great demand due to projected nationwide medical personnel shortages over the next decade and are essential to...for the first year, in order to assist the services in addressing near- term personnel shortages . It also provides a consistent staffing standard...dentists, medical service corps, and veterinarians , to name a few, at the work center level across Army fixed military treatment facilities. The model uses

  20. Monitoring of health care personnel employee and occupational health immunization program practices in the United States.

    PubMed

    Carrico, Ruth M; Sorrells, Nikka; Westhusing, Kelly; Wiemken, Timothy

    2014-01-01

    Recent studies have identified concerns with various elements of health care personnel immunization programs, including the handling and management of the vaccine. The purpose of this study was to assess monitoring processes that support evaluation of the care of vaccines in health care settings. An 11-question survey instrument was developed for use in scripted telephone surveys. State health departments in all 50 states in the United States and the District of Columbia were the target audience for the surveys. Data from a total of 47 states were obtained and analyzed. No states reported an existing monitoring process for evaluation of health care personnel immunization programs in their states. Our assessment indicates that vaccine evaluation processes for health care facilities are rare to nonexistent in the United States. Identifying existing practice gaps and resultant opportunities for improvements may be an important safety initiative that protects patients and health care personnel. Copyright © 2014 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  1. 10 CFR 34.83 - Records of personnel monitoring procedures.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 1 2012-01-01 2012-01-01 false Records of personnel monitoring procedures. 34.83 Section 34.83 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Recordkeeping Requirements § 34.83 Records of personnel...

  2. 10 CFR 34.83 - Records of personnel monitoring procedures.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 1 2013-01-01 2013-01-01 false Records of personnel monitoring procedures. 34.83 Section 34.83 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Recordkeeping Requirements § 34.83 Records of personnel...

  3. 10 CFR 34.83 - Records of personnel monitoring procedures.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Records of personnel monitoring procedures. 34.83 Section 34.83 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Recordkeeping Requirements § 34.83 Records of personnel...

  4. 10 CFR 34.83 - Records of personnel monitoring procedures.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Records of personnel monitoring procedures. 34.83 Section 34.83 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Recordkeeping Requirements § 34.83 Records of personnel...

  5. 10 CFR 34.83 - Records of personnel monitoring procedures.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 1 2014-01-01 2014-01-01 false Records of personnel monitoring procedures. 34.83 Section 34.83 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Recordkeeping Requirements § 34.83 Records of personnel...

  6. 20 CFR 638.530 - Emergency use of personnel, equipment and facilities.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... facilities. 638.530 Section 638.530 Employees' Benefits EMPLOYMENT AND TRAINING ADMINISTRATION, DEPARTMENT OF LABOR JOB CORPS PROGRAM UNDER TITLE IV-B OF THE JOB TRAINING PARTNERSHIP ACT Center Operations § 638.530 Emergency use of personnel, equipment and facilities. The Job Corps Director may provide emergency...

  7. MINIMIZING OCCUPATIONAL EXPOSURE TO PESTICIDES: PERSONNEL MONITORING

    EPA Science Inventory

    This communication is presented with two objectives in mind. The first objective is to provide an introduction to personnel monitoring of occupational exposure to pesticides for those who are not familiar with this field of investigation. The second objective is to stimulate disc...

  8. Facility effluent monitoring plan for the plutonium uranium extraction facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wiegand, D.L.

    A facility effluent monitoring plan is required by the US Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438-01. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements. This facility effluent monitoring plan shall ensure long-range integrity of themore » effluent monitoring systems by requiring an update whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document must be reviewed annually even if there are no operational changes, and it must be updated at a minimum of every three years.« less

  9. 41 CFR 101-39.102-1 - Records, facilities, personnel, and appropriations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., TRANSPORTATION, AND MOTOR VEHICLES 39-INTERAGENCY FLEET MANAGEMENT SYSTEMS 39.1-Establishment, Modification, and Discontinuance of Interagency Fleet Management Systems § 101-39.102-1 Records, facilities, personnel, and appropriations. (a) If GSA decides to establish a fleet management system, GSA, with the assistance of the...

  10. 40 CFR 271.12 - Requirements for hazardous waste management facilities.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... and 266. These standards shall include: (a) Technical standards for tanks, containers, waste piles...-closure monitoring and maintenance; (e) Groundwater monitoring; (f) Security to prevent unauthorized access to the facility; (g) Facility personnel training; (h) Inspections, monitoring, recordkeeping, and...

  11. 40 CFR 271.12 - Requirements for hazardous waste management facilities.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... and 266. These standards shall include: (a) Technical standards for tanks, containers, waste piles...-closure monitoring and maintenance; (e) Groundwater monitoring; (f) Security to prevent unauthorized access to the facility; (g) Facility personnel training; (h) Inspections, monitoring, recordkeeping, and...

  12. 40 CFR 271.12 - Requirements for hazardous waste management facilities.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... and 266. These standards shall include: (a) Technical standards for tanks, containers, waste piles...-closure monitoring and maintenance; (e) Groundwater monitoring; (f) Security to prevent unauthorized access to the facility; (g) Facility personnel training; (h) Inspections, monitoring, recordkeeping, and...

  13. 40 CFR 271.12 - Requirements for hazardous waste management facilities.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... and 266. These standards shall include: (a) Technical standards for tanks, containers, waste piles...-closure monitoring and maintenance; (e) Groundwater monitoring; (f) Security to prevent unauthorized access to the facility; (g) Facility personnel training; (h) Inspections, monitoring, recordkeeping, and...

  14. 40 CFR 271.12 - Requirements for hazardous waste management facilities.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... and 266. These standards shall include: (a) Technical standards for tanks, containers, waste piles...-closure monitoring and maintenance; (e) Groundwater monitoring; (f) Security to prevent unauthorized access to the facility; (g) Facility personnel training; (h) Inspections, monitoring, recordkeeping, and...

  15. Wireless remote monitoring of critical facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tsai, Hanchung; Anderson, John T.; Liu, Yung Y.

    A method, apparatus, and system are provided for monitoring environment parameters of critical facilities. A Remote Area Modular Monitoring (RAMM) apparatus is provided for monitoring environment parameters of critical facilities. The RAMM apparatus includes a battery power supply and a central processor. The RAMM apparatus includes a plurality of sensors monitoring the associated environment parameters and at least one communication module for transmitting one or more monitored environment parameters. The RAMM apparatus is powered by the battery power supply, controlled by the central processor operating a wireless sensor network (WSN) platform when the facility condition is disrupted. The RAMM apparatusmore » includes a housing prepositioned at a strategic location, for example, where a dangerous build-up of contamination and radiation may preclude subsequent manned entrance and surveillance.« less

  16. A national survey of clubs medical personnel, facilities and protocols in Irish Rugby Union.

    PubMed

    Coughlan, G F; Fullen, B M; McCarthy, C

    2014-03-01

    Rugby Union is one of the most popular sports in Ireland. Participation in all sports carries risk, and there is an onus on governing bodies and those involved in sport to minimise this risk using injury prevention and management programmes. The aim of this study was to evaluate the current status of medical personnel, facilities and equipment in Rugby Union clubs in Ireland. A nationwide cross sectional survey of affiliated clubs in Ireland was undertaken at the beginning of the 2011-2012. Clubs were surveyed on a range of variables including their medical personnel, facilities, equipment, policies and concussion. 47.7 % of those surveyed responded. The majority reported involvement of appropriate medically qualified personnel, having a dedicated medical area/room, a first aid kit and defibrillator, and a demand for first aid courses. This survey provided key information on the current medical status of clubs in Ireland to the governing body. Many clubs have adequate medical resources in place, however a large number do not have medical professionals working with them or own basic medical equipment. The results of this study have lead to the development and implementation of a rugby specific injury prevention and management programme for medical and non-medical personnel at all levels of the game in Ireland.

  17. Healthcare personnel perceptions of hand hygiene monitoring technology.

    PubMed

    Ellingson, Katherine; Polgreen, Philip M; Schneider, Amy; Shinkunas, Laura; Kaldjian, Lauris C; Wright, Donald; Thomas, Geb W; Segre, Alberto M; Herman, Ted; McDonald, L Clifford; Sinkowitz-Cochran, Ronda

    2011-11-01

    To assess healthcare personnel (HCP) perceptions regarding implementation of sensor-based electronic systems for automated hand hygiene adherence monitoring. Using a mixed-methods approach, structured focus groups were designed to elicit quantitative and qualitative responses on familiarity, comfort level, and perceived impact of sensor-based hand hygiene adherence monitoring. A university hospital, a Veterans Affairs hospital, and a community hospital in the Midwest. Focus groups were homogenous by HCP type, with separate groups held for leadership, midlevel management, and frontline personnel at each hospital. Overall, 89 HCP participated in 10 focus groups. Levels of familiarity and comfort with electronic oversight technology varied by HCP type; when compared with frontline HCP, those in leadership positions were significantly more familiar with ([Formula: see text]) and more comfortable with ([Formula: see text]) the technology. The most common concerns cited by participants across groups included lack of accuracy in the data produced, such as the inability of the technology to assess the situational context of hand hygiene opportunities, and the potential punitive use of data produced. Across groups, HCP had decreased tolerance for electronic collection of spatial-temporal data, describing such oversight as Big Brother. While substantial concerns were expressed by all types of HCP, participants' recommendations for effective implementation of electronic oversight technologies for hand hygiene monitoring included addressing accuracy issues before implementation and transparent communication with frontline HCP about the intended use of the data.

  18. 40 CFR 265.16 - Personnel training.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 26 2011-07-01 2011-07-01 false Personnel training. 265.16 Section 265... FACILITIES General Facility Standards § 265.16 Personnel training. (a)(1) Facility personnel must successfully complete a program of classroom instruction or on-the-job training that teaches them to perform...

  19. Training Materials for Animal Facility Personnel. January 1990-January 1995. Quick Bibliography Series.

    ERIC Educational Resources Information Center

    Kreger, Michael D.

    This annotated bibliography contains 167 citations of training materials for animal facility personnel that were enbtered in the AGRICOLA database between January 1979 and February 1995. Citations of journal articles, books, and audiovisual materials are included. A wide variety of publication types are represented, including the following:…

  20. JSC MCC Bldg 30 personnel monitor STS-26 post landing activities

    NASA Image and Video Library

    1988-10-03

    JSC Mission Control Center (MCC) Bldg 30 flight control room (FCR) personnel monitor STS-26 post landing activities and ceremonies at Edwards Air Force Base (EAFB) via their monitors. Displayed on front screens are approach and landing diagrams, data, the space shuttle program insignia, the STS-26 mission insignia, the Mission Operations Directorate insignia, and the STS-26 crew standing in front of Discovery, Orbiter Vehicle (OV) 103.

  1. Monitoring precipitation chemistry on the Monongahela National Forest

    Treesearch

    John B. Currier; Gerald M. Aubertin

    1976-01-01

    Personnel from the Monongahela National Forest and the Northeastern Forest Experiment Station are collaborating in forest-wide monitoring of precipitation chemistry. Present monitoring facilities consist of one continuous precipitation collector/pH recorder and 12 precipitation collectors. Samples collected in these facilities are picked up and analyzed biweekly for...

  2. 36 CFR 1260.42 - What are the procedures for agency personnel to review records at a NARA facility?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... SECURITY INFORMATION Systematic Review § 1260.42 What are the procedures for agency personnel to review... 36 Parks, Forests, and Public Property 3 2010-07-01 2010-07-01 false What are the procedures for agency personnel to review records at a NARA facility? 1260.42 Section 1260.42 Parks, Forests, and Public...

  3. 33 CFR 143.105 - Personnel landings.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Personnel landings. 143.105...) OUTER CONTINENTAL SHELF ACTIVITIES DESIGN AND EQUIPMENT OCS Facilities § 143.105 Personnel landings. (a) Sufficient personnel landings shall be provided on each manned OCS facility to assure safe access and egress...

  4. 33 CFR 143.105 - Personnel landings.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Personnel landings. 143.105...) OUTER CONTINENTAL SHELF ACTIVITIES DESIGN AND EQUIPMENT OCS Facilities § 143.105 Personnel landings. (a) Sufficient personnel landings shall be provided on each manned OCS facility to assure safe access and egress...

  5. Care Planning, Quality Assurance, and Personnel Management in Long-Term Care Facilities. Final Report.

    ERIC Educational Resources Information Center

    Patchner, Michael A.; Balgopal, Pallassana R.

    Three studies were undertaken to examine topics of care planning, personnel management, and quality assurance in long-term care facilities. The first study examined the formulation and implementation processes of care planning for nursing home residents. The exemplary homes' care planning included the existence of strong care planning leadership,…

  6. 40 CFR 264.16 - Personnel training.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 26 2011-07-01 2011-07-01 false Personnel training. 264.16 Section 264... Facility Standards § 264.16 Personnel training. (a)(1) Facility personnel must successfully complete a program of classroom instruction or on-the-job training that teaches them to perform their duties in a way...

  7. 40 CFR 264.16 - Personnel training.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 25 2010-07-01 2010-07-01 false Personnel training. 264.16 Section 264... Facility Standards § 264.16 Personnel training. (a)(1) Facility personnel must successfully complete a program of classroom instruction or on-the-job training that teaches them to perform their duties in a way...

  8. Vocabulary for Healthcare Personnel.

    ERIC Educational Resources Information Center

    Falagrady, Teresa

    Developed by educators from the Emily Griffith Opportunity School, this teacher's guide presents a course in health care vocabulary for secretaries, medical records personnel, laboratory assistants, shipping personnel, and patient relations personnel in health care facilities. The course, which should require 10-14 hours of instruction, contains…

  9. 12 CFR 550.160 - What personnel and facilities may I use to perform fiduciary services?

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 12 Banks and Banking 5 2011-01-01 2011-01-01 false What personnel and facilities may I use to perform fiduciary services? 550.160 Section 550.160 Banks and Banking OFFICE OF THRIFT SUPERVISION, DEPARTMENT OF THE TREASURY FIDUCIARY POWERS OF SAVINGS ASSOCIATIONS Exercising Fiduciary Powers Fiduciary...

  10. 12 CFR 550.160 - What personnel and facilities may I use to perform fiduciary services?

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 12 Banks and Banking 5 2010-01-01 2010-01-01 false What personnel and facilities may I use to perform fiduciary services? 550.160 Section 550.160 Banks and Banking OFFICE OF THRIFT SUPERVISION, DEPARTMENT OF THE TREASURY FIDUCIARY POWERS OF SAVINGS ASSOCIATIONS Exercising Fiduciary Powers Fiduciary...

  11. Distributed intelligent monitoring and reporting facilities

    NASA Astrophysics Data System (ADS)

    Pavlou, George; Mykoniatis, George; Sanchez-P, Jorge-A.

    1996-06-01

    Distributed intelligent monitoring and reporting facilities are of paramount importance in both service and network management as they provide the capability to monitor quality of service and utilization parameters and notify degradation so that corrective action can be taken. By intelligent, we refer to the capability of performing the monitoring tasks in a way that has the smallest possible impact on the managed network, facilitates the observation and summarization of information according to a number of criteria and in its most advanced form and permits the specification of these criteria dynamically to suit the particular policy in hand. In addition, intelligent monitoring facilities should minimize the design and implementation effort involved in such activities. The ISO/ITU Metric, Summarization and Performance management functions provide models that only partially satisfy the above requirements. This paper describes our extensions to the proposed models to support further capabilities, with the intention to eventually lead to fully dynamically defined monitoring policies. The concept of distributing intelligence is also discussed, including the consideration of security issues and the applicability of the model in ODP-based distributed processing environments.

  12. 36 CFR 1260.42 - What are the procedures for agency personnel to review records at a NARA facility?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 36 Parks, Forests, and Public Property 3 2011-07-01 2011-07-01 false What are the procedures for agency personnel to review records at a NARA facility? 1260.42 Section 1260.42 Parks, Forests, and Public... reviewers; (2) Provide space for agency reviewers in the facility in which the records are located to the...

  13. Assessing and Monitoring Student Progress in an E-Learning Personnel Preparation Environment.

    ERIC Educational Resources Information Center

    Meyen, Edward L.; Aust, Ronald J.; Bui, Yvonne N.; Isaacson, Robert

    2002-01-01

    Discussion of e-learning in special education personnel preparation focuses on student assessment in e-learning environments. It includes a review of the literature, lessons learned by the authors from assessing student performance in e-learning environments, a literature perspective on electronic portfolios in monitoring student progress, and the…

  14. Condition Monitoring of Large-Scale Facilities

    NASA Technical Reports Server (NTRS)

    Hall, David L.

    1999-01-01

    This document provides a summary of the research conducted for the NASA Ames Research Center under grant NAG2-1182 (Condition-Based Monitoring of Large-Scale Facilities). The information includes copies of view graphs presented at NASA Ames in the final Workshop (held during December of 1998), as well as a copy of a technical report provided to the COTR (Dr. Anne Patterson-Hine) subsequent to the workshop. The material describes the experimental design, collection of data, and analysis results associated with monitoring the health of large-scale facilities. In addition to this material, a copy of the Pennsylvania State University Applied Research Laboratory data fusion visual programming tool kit was also provided to NASA Ames researchers.

  15. Target, Act, Graph (TAG): Teachers Empowering Classroom Resource Personnel in Monitoring Student Progress

    ERIC Educational Resources Information Center

    Rizzi, Gleides A. L.

    2016-01-01

    This article provides teachers in rural settings with suggestions on how to engage classroom resource personnel (i.e., volunteers, instructional assistants) in monitoring students' achievement. The target, act, and graph (TAG) strategy offers rural special educators ways to empower classroom resource persons through training and use of the TAG…

  16. 21 CFR 1301.77 - Security controls for freight forwarding facilities.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... subject to continuous monitoring by security personnel will be deemed to meet the requirements of Section... forwarding facility must be packed in sealed, unmarked shipping containers. [65 FR 44678, July 19, 2000; 65...

  17. 21 CFR 1301.77 - Security controls for freight forwarding facilities.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... subject to continuous monitoring by security personnel will be deemed to meet the requirements of Section... forwarding facility must be packed in sealed, unmarked shipping containers. [65 FR 44678, July 19, 2000; 65...

  18. 21 CFR 1301.77 - Security controls for freight forwarding facilities.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... subject to continuous monitoring by security personnel will be deemed to meet the requirements of Section... forwarding facility must be packed in sealed, unmarked shipping containers. [65 FR 44678, July 19, 2000; 65...

  19. 21 CFR 1301.77 - Security controls for freight forwarding facilities.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... subject to continuous monitoring by security personnel will be deemed to meet the requirements of Section... forwarding facility must be packed in sealed, unmarked shipping containers. [65 FR 44678, July 19, 2000; 65...

  20. 21 CFR 1301.77 - Security controls for freight forwarding facilities.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... subject to continuous monitoring by security personnel will be deemed to meet the requirements of Section... forwarding facility must be packed in sealed, unmarked shipping containers. [65 FR 44678, July 19, 2000; 65...

  1. Proposal for Monitoring Within the Centrifuge Cascades of Uranium Enrichment Facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Farrar, David R.

    2017-04-01

    Safeguards are technical measures implemented by the International Atomic Energy Agency (IAEA) to independently verify that nuclear material is not diverted from peaceful purposes to weapons (IAEA, 2017a). Safeguards implemented at uranium enrichment facilities (facilities hereafter) include enrichment monitors (IAEA, 2011). Figure 1 shows a diagram of how a facility could be monitored. The use of a system for monitoring within centrifuge cascades is proposed.

  2. Recent Upgrades at the Safety and Tritium Applied Research Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cadwallader, Lee Charles; Merrill, Brad Johnson; Stewart, Dean Andrew

    This paper gives a brief overview of the Safety and Tritium Applied Research (STAR) facility operated by the Fusion Safety Program (FSP) at the Idaho National Laboratory (INL). FSP researchers use the STAR facility to carry out experiments in tritium permeation and retention in various fusion materials, including wall armor tile materials. FSP researchers also perform other experimentation as well to support safety assessment in fusion development. This lab, in its present two-building configuration, has been in operation for over ten years. The main experiments at STAR are briefly described. This paper discusses recent work to enhance personnel safety atmore » the facility. The STAR facility is a Department of Energy less than hazard category 3 facility; the personnel safety approach calls for ventilation and tritium monitoring for radiation protection. The tritium areas of STAR have about 4 to 12 air changes per hour, with air flow being once through and then routed to the facility vent stack. Additional radiation monitoring has been installed to read the laboratory room air where experiments with tritium are conducted. These ion chambers and bubblers are used to verify that no significant tritium concentrations are present in the experiment rooms. Standby electrical power has been added to the facility exhaust blower so that proper ventilation will now operate during commercial power outages as well as the real-time tritium air monitors.« less

  3. 9 CFR 590.560 - Health and hygiene of personnel.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Health and hygiene of personnel. 590.560 Section 590.560 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF..., Processing, and Facility Requirements § 590.560 Health and hygiene of personnel. (a) Personnel facilities...

  4. 9 CFR 590.560 - Health and hygiene of personnel.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 9 Animals and Animal Products 2 2011-01-01 2011-01-01 false Health and hygiene of personnel. 590.560 Section 590.560 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF..., Processing, and Facility Requirements § 590.560 Health and hygiene of personnel. (a) Personnel facilities...

  5. Personnel Safety on Electrified Railroads

    DOT National Transportation Integrated Search

    1980-06-01

    Potential electrical hazards to fire, police, and rescue personnel responding to emergencies on electrified railways are examined. Data on descriptions of electrical facilities, types of accidents and danger to emergency personnel, and reviews of ope...

  6. 12 CFR 550.170 - May my other departments or affiliates use fiduciary personnel and facilities to perform other...

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 12 Banks and Banking 5 2010-01-01 2010-01-01 false May my other departments or affiliates use fiduciary personnel and facilities to perform other services? 550.170 Section 550.170 Banks and Banking OFFICE OF THRIFT SUPERVISION, DEPARTMENT OF THE TREASURY FIDUCIARY POWERS OF SAVINGS ASSOCIATIONS...

  7. 12 CFR 550.170 - May my other departments or affiliates use fiduciary personnel and facilities to perform other...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 12 Banks and Banking 5 2011-01-01 2011-01-01 false May my other departments or affiliates use fiduciary personnel and facilities to perform other services? 550.170 Section 550.170 Banks and Banking OFFICE OF THRIFT SUPERVISION, DEPARTMENT OF THE TREASURY FIDUCIARY POWERS OF SAVINGS ASSOCIATIONS...

  8. 9 CFR 592.95 - Facilities and equipment to be furnished for use of inspection program personnel in performing...

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Facilities and equipment to be furnished for use of inspection program personnel in performing service. 592.95 Section 592.95 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE EGG PRODUCTS INSPECTION...

  9. Mortality monitoring design for utility-scale solar power facilities

    USGS Publications Warehouse

    Huso, Manuela; Dietsch, Thomas; Nicolai, Chris

    2016-05-27

    IntroductionSolar power represents an important and rapidly expanding component of the renewable energy portfolio of the United States (Lovich and Ennen, 2011; Hernandez and others, 2014). Understanding the impacts of renewable energy development on wildlife is a priority for the U.S. Fish and Wildlife Service (FWS) in compliance with Department of Interior Order No. 3285 (U.S. Department of the Interior, 2009) to “develop best management practices for renewable energy and transmission projects on the public lands to ensure the most environmentally responsible development and delivery of renewable energy.” Recent studies examining effects of renewable energy development on mortality of migratory birds have primarily focused on wind energy (California Energy Commission and California Department of Fish and Game, 2007), and in 2012 the FWS published guidance for addressing wildlife conservation concerns at all stages of land-based wind energy development (U.S. Fish and Wildlife Service, 2012). As yet, no similar guidelines exist for solar development, and no published studies have directly addressed the methodology needed to accurately estimate mortality of birds and bats at solar facilities. In the absence of such guidelines, ad hoc methodologies applied to solar energy projects may lead to estimates of wildlife mortality rates that are insufficiently accurate and precise to meaningfully inform conversations regarding unintended consequences of this energy source and management decisions to mitigate impacts. Although significant advances in monitoring protocols for wind facilities have been made in recent years, there remains a need to provide consistent guidance and study design to quantify mortality of bats, and resident and migrating birds at solar power facilities (Walston and others, 2015).In this document, we suggest methods for mortality monitoring at solar facilities that are based on current methods used at wind power facilities but adapted for the

  10. Proceedings of the Symposium on Training of Nuclear Facility Personnel (7th, Orlando, Florida, April 27-30, 1987).

    ERIC Educational Resources Information Center

    Oak Ridge National Lab., TN.

    These proceedings contain program highlights as well as 45 papers given during six sessions of the Symposium on Training of Nuclear Facility Personnel. The six sessions are entitled: (1) the training challenge; (2) influences on nuclear training; (3) the human factors--training partnership and factors affecting job performance; (4) current…

  11. 9 CFR 592.95 - Facilities and equipment to be furnished for use of inspection program personnel in performing...

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 9 Animals and Animal Products 2 2012-01-01 2012-01-01 false Facilities and equipment to be furnished for use of inspection program personnel in performing service. 592.95 Section 592.95 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE EGG PRODUCTS INSPECTION VOLUNTARY INSPECTION OF EGG PRODUCTS Performanc...

  12. 9 CFR 592.95 - Facilities and equipment to be furnished for use of inspection program personnel in performing...

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 9 Animals and Animal Products 2 2013-01-01 2013-01-01 false Facilities and equipment to be furnished for use of inspection program personnel in performing service. 592.95 Section 592.95 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE EGG PRODUCTS INSPECTION VOLUNTARY INSPECTION OF EGG PRODUCTS Performanc...

  13. 9 CFR 592.95 - Facilities and equipment to be furnished for use of inspection program personnel in performing...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 9 Animals and Animal Products 2 2011-01-01 2011-01-01 false Facilities and equipment to be furnished for use of inspection program personnel in performing service. 592.95 Section 592.95 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE EGG PRODUCTS INSPECTION VOLUNTARY INSPECTION OF EGG PRODUCTS Performanc...

  14. 9 CFR 592.95 - Facilities and equipment to be furnished for use of inspection program personnel in performing...

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 9 Animals and Animal Products 2 2014-01-01 2014-01-01 false Facilities and equipment to be furnished for use of inspection program personnel in performing service. 592.95 Section 592.95 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE EGG PRODUCTS INSPECTION VOLUNTARY INSPECTION OF EGG PRODUCTS Performanc...

  15. Vaccine storage and cold chain monitoring in the North West region of Cameroon: a cross sectional study.

    PubMed

    Yakum, Martin Ndinakie; Ateudjieu, Jerome; Walter, Ebile Akoh; Watcho, Pierre

    2015-04-14

    The cold chain must be monitored continuously in order to guarantee vaccines' quality. From field reports and previous studies, cold chain monitoring for expanded program on immunization (EPI) is still not satisfactory in Cameroon. This study was conducted to evaluate the availability and functioning of cold chain equipment as well as knowledge. It was a cross-sectional study involving a multistage sampling. 3urban and 5rural districts were selected randomly from the 19 health districts of the North West region. In each district all the health facilities taking part in the EPI were targeted. Data were collected using a questionnaire administered face to face to health personnel and with an observational grid to assess availability, functioning, and monitoring of cold chain equipment and power supply. The data were analyzed using the epi-info software. A total of 70 health facilities were contacted and 65(88.6%) of them included in the study. Fifty-three (81.5%) out of 65 health facilities had at least one functional vaccine refrigerator. The national guideline of EPI was not present in 21(33.9%) health facilities. Temperature chart was complete/correctly filled in 25(50.0%) of the 50(96.2%) facilities having it. About 14 (26.9%) of the health facilities record at least one abnormal temperature during the last 2 months following data collection. Seventeen (28.3%) personnel did not know the correct vaccine storage temperature. The availability of vaccine storage equipment for EPI is acceptable in the North West Region of Cameroon but the capacity of those in charge to properly monitor it in all health facilities is still limited. To ensure that vaccines administered in the North West Region are stored at the recommended temperature, all District Health Services should train and regularly supervise the health personnel in charge of cold chain monitoring.

  16. Factors affecting recruitment of physical therapy personnel in Utah.

    PubMed

    Okerlund, V W; Jackson, P B; Parsons, R J

    1994-02-01

    This study assessed the current and future needs of physical therapy personnel in Utah, including both physical therapists and physical therapist assistants. Three hundred twenty-two health care facilities selected from four major employer groups in Utah and a total of 590 physical therapy personnel were surveyed. Two hundred forty-four health care facilities (76%) and 198 physical therapy personnel (33.6%) responded. Two survey instruments were developed: one to assess the current and future supply and demand of physical therapy personnel in Utah, and the other to determine recruitment and retention factors. Utah health care facilities projected a need for 46 additional physical therapists and 28 additional physical therapist assistants in 1992. Surveyed physical therapy personnel reported feeling satisfied with the profession and had chosen the profession through a person of influence. Freedom on the job and development of skills were the most often mentioned determinants of job satisfaction, and pay and benefits were the major determinants of retention. Physical therapy personnel should have a role in recruitment efforts. Physical therapy personnel have many options for employment and often choose to seek a diversity of opportunities for better compensation.

  17. 33 CFR 127.707 - Security personnel.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false Security personnel. 127.707 Section 127.707 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED... Waterfront Facilities Handling Liquefied Natural Gas Security § 127.707 Security personnel. The operator...

  18. 33 CFR 127.707 - Security personnel.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false Security personnel. 127.707 Section 127.707 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED... Waterfront Facilities Handling Liquefied Natural Gas Security § 127.707 Security personnel. The operator...

  19. 33 CFR 127.707 - Security personnel.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false Security personnel. 127.707 Section 127.707 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED... Waterfront Facilities Handling Liquefied Natural Gas Security § 127.707 Security personnel. The operator...

  20. 33 CFR 127.707 - Security personnel.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Security personnel. 127.707 Section 127.707 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED... Waterfront Facilities Handling Liquefied Natural Gas Security § 127.707 Security personnel. The operator...

  1. 9 CFR 2.32 - Personnel qualifications.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 9 Animals and Animal Products 1 2012-01-01 2012-01-01 false Personnel qualifications. 2.32 Section 2.32 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE ANIMAL WELFARE REGULATIONS Research Facilities § 2.32 Personnel qualifications. (a) It shall be...

  2. 9 CFR 2.32 - Personnel qualifications.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Personnel qualifications. 2.32 Section 2.32 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE ANIMAL WELFARE REGULATIONS Research Facilities § 2.32 Personnel qualifications. (a) It shall be...

  3. 9 CFR 2.32 - Personnel qualifications.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 9 Animals and Animal Products 1 2014-01-01 2014-01-01 false Personnel qualifications. 2.32 Section 2.32 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE ANIMAL WELFARE REGULATIONS Research Facilities § 2.32 Personnel qualifications. (a) It shall be...

  4. 9 CFR 2.32 - Personnel qualifications.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 9 Animals and Animal Products 1 2011-01-01 2011-01-01 false Personnel qualifications. 2.32 Section 2.32 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE ANIMAL WELFARE REGULATIONS Research Facilities § 2.32 Personnel qualifications. (a) It shall be...

  5. 9 CFR 2.32 - Personnel qualifications.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 9 Animals and Animal Products 1 2013-01-01 2013-01-01 false Personnel qualifications. 2.32 Section 2.32 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE ANIMAL WELFARE REGULATIONS Research Facilities § 2.32 Personnel qualifications. (a) It shall be...

  6. Environmental monitoring handbook for coal conversion facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Salk, M.S.; DeCicco, S.G.

    1978-05-01

    The primary objectives of the Department of Energy's (DOE) coal conversion program are to demonstrate the environmental acceptability, technical feasibility, and economic viability of various technologies for gaseous, liquid, and solid fuels from coal. The Environmental Monitoring Handbook for Coal Conversion Facilities will help accomplish the objective of environmental acceptability by guiding the planning and execution of socioeconomic and environmental monitoring programs for demonstration facilities. These programs will provide information adequate to (1) predict, insofar as is possible, the potential impacts of construction and operation of a coal conversion plant, (2) verify the occurrence of these or any other impactsmore » during construction and operation, (3) determine the adequacy of mitigating measures to protect the environment, (4) develop effluent source terms for process discharges, and (5) determine the effectiveness of pollution control equipment. Although useful in a variety of areas, the handbook is intended primarily for contractors who, as industrial partners with DOE, are building coal conversion plants. For the contractor it is a practical guide on (1) the methodology for developing site- and process-specific environmental monitoring programs, (2) state-of-the-art sampling and analytical techniques, and (3) impact analyses.To correspond to the phases of project activity, the subject matter is divided into four stages of monitoring: (1) a reconnaissance or synoptic survey, (2) preconstruction or baseline, (3) construction, and (4) operation, including process monitoring (prepared by Radian Corp., McLean, Va.). For each stage of monitoring, guidelines are given on socioeconomics, aquatic and terrestrial ecology, air quality and meteorology, surface and groundwater quality, geohydrology and soil survey, and surface water hydrology.« less

  7. Observations on personnel dosimetry for radiotherapy personnel operating high-energy LINACs.

    PubMed

    Glasgow, G P; Eichling, J; Yoder, R C

    1986-06-01

    A series of measurements were conducted to determine the cause of a sudden increase in personnel radiation exposures. One objective of the measurements was to determine if the increases were related to changing from film dosimeters exchanged monthly to TLD-100 dosimeters exchanged quarterly. While small increases were observed in the dose equivalents of most employees, the dose equivalents of personnel operating medical electron linear accelerators with energies greater than 20 MV doubled coincidentally with the change in the personnel dosimeter program. The measurements indicated a small thermal neutron radiation component around the accelerators operated by these personnel. This component caused the doses measured with the TLD-100 dosimeters to be overstated. Therefore, the increase in these personnel dose equivalents was not due to changes in work habits or radiation environments. Either film or TLD-700 dosimeters would be suitable for personnel monitoring around high-energy linear accelerators. The final choice would depend on economics and personal preference.

  8. 33 CFR 154.840 - Personnel training.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Personnel training. 154.840... Personnel training. (a) A person in charge of a transfer operation utilizing a vapor control system must have completed a training program covering the particular system installed at the facility. Training...

  9. 33 CFR 154.840 - Personnel training.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Personnel training. 154.840... Personnel training. (a) A person in charge of a transfer operation utilizing a vapor control system must have completed a training program covering the particular system installed at the facility. Training...

  10. Recommendations for Health Monitoring and Reporting for Zebrafish Research Facilities

    PubMed Central

    Crim, Marcus J.; Lieggi, Christine

    2016-01-01

    Abstract The presence of subclinical infection or clinical disease in laboratory zebrafish may have a significant impact on research results, animal health and welfare, and transfer of animals between institutions. As use of zebrafish as a model of disease increases, a harmonized method for monitoring and reporting the health status of animals will facilitate the transfer of animals, allow institutions to exclude diseases that may negatively impact their research programs, and improve animal health and welfare. All zebrafish facilities should implement a health monitoring program. In this study, we review important aspects of a health monitoring program, including choice of agents, samples for testing, available testing methodologies, housing and husbandry, cost, test subjects, and a harmonized method for reporting results. Facilities may use these recommendations to implement their own health monitoring program. PMID:26991393

  11. PRD3000: A novel Personnel Radiation Detector with Radiation Exposure Monitoring

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fallu-Labruyere, A.; Micou, C.; Schulcz, F.

    PRD3000{sup TM} is a novel Personal Radiation Detector (PRD) with personnel radiation dose exposure monitoring. It is intended for First Responders, Law Enforcement, Customs Inspectors protecting critical infrastructures for detecting unexpected radioactive sources, who also need real time Hp(10) dose equivalent information. Traditional PRD devices use scintillator materials instrumented through either a photomultiplier tube or a photodiode photodetector. While the former is bulky and sensitive to magnetic fields, the latter has to compromise radiation sensitivity and energy threshold given its current noise per unit of photo-detection surface. Recently, solid state photodetectors (SiPM), based on arrays of Geiger operated diodes, havemore » emerged as a scalable digital photodetector for photon counting. Their strong breakdown voltage temperature dependence (on the order of tens of milli-volts per K) has however limited their use for portable instruments where strong temperature gradients can be experienced, and limited power is available to temperature stabilize. The PRD3000 is based on the industry standard DMC3000 active dosimeter that complies with IEC 61526 Ed. 3 and ANSI 42.20 for direct reading personal dose equivalent meters and active personnel radiation monitors. An extension module is based on a CsI(Tl) scintillator readout by a temperature compensated SiPM. Preliminary nuclear tests combined with a measured continuous operation in excess of 240 hours from a single AAA battery cell indicate that the PRD3000 complies with the IEC 62401 Ed.2 and ANSI 42.32 without sacrificing battery life time. We present a summary of the device test results, starting with performance stability over a temperature range of - 20 deg. C to 50 deg. C, false alarm rates and dynamic response time. (authors)« less

  12. Hanford Site near-facility environmental monitoring annual report, calendar year 1997

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Perkins, C.J.

    1998-07-28

    Near-facility environmental monitoring provides a means to measure the impacts of operations, waste management, and remediation activities on the environment adjacent to facilities and ensure compliance with local, state, and federal environmental regulations. Specifically, near-facility environmental monitoring monitors new and existing sites, processes, and facilities for potential impacts and releases; fugitive emissions and diffuse sources associated with contaminated areas, facilities (both active and those undergoing surveillance and maintenance), and environmental restoration activities. External radiation, ambient air particulates, ground and surface water, soil, sediment, and biota (plants and animals) are sampled or monitored. Parameters include, as appropriate, radionuclides; radiation fields; chemicalmore » or physical constituents, such as nitrates; pH; and water temperature. All ambient air results were below the US Department of Energy (DOE) Derived Concentration Guides (DCGs). Groundwater concentrations at the two wells at the 107-N Facility were below both the DOE DCG and US Environmental Protection Agency Interim Drinking Water Standards for gamma emitting radionuclides. Soil and vegetation results were generally within historic ranges and mostly below the Accessible Soil Concentration limits (included in HNF-PRO-454, Inactive Waste Sites) with the exception of one soil sampling location at 1 00 N Area. External radiation fields continued an overall downward trend. Surface water disposal unit samples (water, sediment, and aquatic vegetation) showed radionuclide concentrations below their respective DCG and Accessible Soil Concentration limits. The 100 N Area Columbia river shoreline springs results were below DCGs with the exception of one Sr concentration. More than 4,600 ha (11,300 acres) of radiologically controlled areas were surveyed in 1997, approximately the same as in 1996.« less

  13. Measuring and monitoring KIPT Neutron Source Facility Reactivity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cao, Yan; Gohar, Yousry; Zhong, Zhaopeng

    2015-08-01

    Argonne National Laboratory (ANL) of USA and Kharkov Institute of Physics and Technology (KIPT) of Ukraine have been collaborating on developing and constructing a neutron source facility at Kharkov, Ukraine. The facility consists of an accelerator-driven subcritical system. The accelerator has a 100 kW electron beam using 100 MeV electrons. The subcritical assembly has k eff less than 0.98. To ensure the safe operation of this neutron source facility, the reactivity of the subcritical core has to be accurately determined and continuously monitored. A technique which combines the area-ratio method and the flux-to-current ratio method is purposed to determine themore » reactivity of the KIPT subcritical assembly at various conditions. In particular, the area-ratio method can determine the absolute reactivity of the subcritical assembly in units of dollars by performing pulsed-neutron experiments. It provides reference reactivities for the flux-to-current ratio method to track and monitor the reactivity deviations from the reference state while the facility is at other operation modes. Monte Carlo simulations are performed to simulate both methods using the numerical model of the KIPT subcritical assembly. It is found that the reactivities obtained from both the area-ratio method and the flux-to-current ratio method are spatially dependent on the neutron detector locations and types. Numerical simulations also suggest optimal neutron detector locations to minimize the spatial effects in the flux-to-current ratio method. The spatial correction factors are calculated using Monte Carlo methods for both measuring methods at the selected neutron detector locations. Monte Carlo simulations are also performed to verify the accuracy of the flux-to-current ratio method in monitoring the reactivity swing during a fuel burnup cycle.« less

  14. [Attitudes of personnel monitoring intra-hospital adverse events in Colombia].

    PubMed

    Gaitán-Duarte, Hernando; Gómez Sánchez, Pió I; Eslava-Schmalbach, Javier

    2009-10-01

    Detecting adverse events (AE) is part of managing hospitalised patients' safety. Suitable AE monitoring is affected by many factors regarding any particular institution and its workers. This article was aimed at describing the difficulties emerging from identifying and evaluating events and suggested interventions from the workers' viewpoint. Qualitative research. A focus group was formed with key informants from previous research entitled 'The incidence and avoidability of adverse events in three institutions in Colombia, 2006.' A conceptual framework was constructed based on publications pertaining to AEs and health-providing institutions; summaries were made by topic regarding the content of the focus group's work by systematising, categorising and readjusting the data. The triangulation method was used for guar-anteeing its credibility, transferability, reliability and that it could be confirmed. It is commonly thought that monitoring AE only consists of taking inventories related to negative work consequences into account; this opinion has been determined by prior organisational culture. Strategies used for increasing AE reporting were: intrapersonal work, raising awareness that nobody is exempt from being involved in an adverse event and encouraging administrative support for resolving deficiencies. The prospective monitoring method becomes hampered when applying it to services involving a large volume of information. A tendency was observed for specialist committees to underestimate an event's association. Heath workers, support personnel and management must have mutual confidence and adopt team-work so that future AE may be prevented.

  15. Facilities and support systems for a 90-day test of a regenerative life support system

    NASA Technical Reports Server (NTRS)

    Malin, R. L.

    1972-01-01

    A 90-day test is reported of a regenerative life support system which was completed in a space station simulator. The long duration of the test and the fact that it was manned, imposed rigid reliability and safety requirements on the facility. Where adequate reliability could not be built into essential facility systems, either backup systems or components were provided. Awareness was intensified by: (1) placing signs on every piece of equipment that could affect the test, (2) painting switches on all breaker panels a bright contrasting color, (3) restricting access to the test control area, and (4) informing personnel in the facility (other than test personnel) of test activities. It is concluded that the basic facility is satisfactory for conducting long-duration manned tests, and it is recommended that all monitor and alarm functions be integrated into a single operation.

  16. On possibilities of using global monitoring in effective prevention of tailings storage facilities failures.

    PubMed

    Stefaniak, Katarzyna; Wróżyńska, Magdalena

    2018-02-01

    Protection of common natural goods is one of the greatest challenges man faces every day. Extracting and processing natural resources such as mineral deposits contributes to the transformation of the natural environment. The number of activities designed to keep balance are undertaken in accordance with the concept of integrated order. One of them is the use of comprehensive systems of tailings storage facility monitoring. Despite the monitoring, system failures still occur. The quantitative aspect of the failures illustrates both the scale of the problem and the quantitative aspect of the consequences of tailings storage facility failures. The paper presents vast possibilities provided by the global monitoring in the effective prevention of these failures. Particular attention is drawn to the potential of using multidirectional monitoring, including technical and environmental monitoring by the example of one of the world's biggest hydrotechnical constructions-Żelazny Most Tailings Storage Facility (TSF), Poland. Analysis of monitoring data allows to take preventive action against construction failures of facility dams, which can have devastating effects on human life and the natural environment.

  17. 10 CFR 36.55 - Personnel monitoring.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... REGULATORY COMMISSION LICENSES AND RADIATION SAFETY REQUIREMENTS FOR IRRADIATORS Operation of Irradiators... accident dose ranges (see 10 CFR 20.1501(c)). Each personnel dosimeter must be assigned to and worn by only... processed at least quarterly. (b) Other individuals who enter the radiation room of a panoramic irradiator...

  18. 10 CFR 36.55 - Personnel monitoring.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... REGULATORY COMMISSION LICENSES AND RADIATION SAFETY REQUIREMENTS FOR IRRADIATORS Operation of Irradiators... accident dose ranges (see 10 CFR 20.1501(c)). Each personnel dosimeter must be assigned to and worn by only... processed at least quarterly. (b) Other individuals who enter the radiation room of a panoramic irradiator...

  19. 10 CFR 36.55 - Personnel monitoring.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... REGULATORY COMMISSION LICENSES AND RADIATION SAFETY REQUIREMENTS FOR IRRADIATORS Operation of Irradiators... accident dose ranges (see 10 CFR 20.1501(c)). Each personnel dosimeter must be assigned to and worn by only... processed at least quarterly. (b) Other individuals who enter the radiation room of a panoramic irradiator...

  20. 10 CFR 36.55 - Personnel monitoring.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... REGULATORY COMMISSION LICENSES AND RADIATION SAFETY REQUIREMENTS FOR IRRADIATORS Operation of Irradiators... accident dose ranges (see 10 CFR 20.1501(c)). Each personnel dosimeter must be assigned to and worn by only... processed at least quarterly. (b) Other individuals who enter the radiation room of a panoramic irradiator...

  1. 10 CFR 36.55 - Personnel monitoring.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... REGULATORY COMMISSION LICENSES AND RADIATION SAFETY REQUIREMENTS FOR IRRADIATORS Operation of Irradiators... accident dose ranges (see 10 CFR 20.1501(c)). Each personnel dosimeter must be assigned to and worn by only... processed at least quarterly. (b) Other individuals who enter the radiation room of a panoramic irradiator...

  2. Combined analysis of modeled and monitored SO2 concentrations at a complex smelting facility.

    PubMed

    Rehbein, Peter J G; Kennedy, Michael G; Cotsman, David J; Campeau, Madonna A; Greenfield, Monika M; Annett, Melissa A; Lepage, Mike F

    2014-03-01

    Vale Canada Limited owns and operates a large nickel smelting facility located in Sudbury, Ontario. This is a complex facility with many sources of SO2 emissions, including a mix of source types ranging from passive building roof vents to North America's tallest stack. In addition, as this facility performs batch operations, there is significant variability in the emission rates depending on the operations that are occurring. Although SO2 emission rates for many of the sources have been measured by source testing, the reliability of these emission rates has not been tested from a dispersion modeling perspective. This facility is a significant source of SO2 in the local region, making it critical that when modeling the emissions from this facility for regulatory or other purposes, that the resulting concentrations are representative of what would actually be measured or otherwise observed. To assess the accuracy of the modeling, a detailed analysis of modeled and monitored data for SO2 at the facility was performed. A mobile SO2 monitor sampled at five locations downwind of different source groups for different wind directions resulting in a total of 168 hr of valid data that could be used for the modeled to monitored results comparison. The facility was modeled in AERMOD (American Meteorological Society/U.S. Environmental Protection Agency Regulatory Model) using site-specific meteorological data such that the modeled periods coincided with the same times as the monitored events. In addition, great effort was invested into estimating the actual SO2 emission rates that would likely be occurring during each of the monitoring events. SO2 concentrations were modeled for receptors around each monitoring location so that the modeled data could be directly compared with the monitored data. The modeled and monitored concentrations were compared and showed that there were no systematic biases in the modeled concentrations. This paper is a case study of a Combined Analysis

  3. Environmental assessment of the Carlsbad Environmental Monitoring and Research Center Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1995-10-01

    This Environmental Assessment has been prepared to determine if the Carlsbad Environmental Monitoring and Research Center (the Center), or its alternatives would have significant environmental impacts that must be analyzed in an Environmental Impact Statement. DOE`s proposed action is to continue funding the Center. While DOE is not funding construction of the planned Center facility, operation of that facility is dependent upon continued funding. To implement the proposed action, the Center would initially construct a facility of approximately 2,300 square meters (25,000 square feet). The Phase 1 laboratory facilities and parking lot will occupy approximately 1.2 hectares (3 acres) ofmore » approximately 8.9 hectares (22 acres) of land which were donated to New Mexico State University (NMSU) for this purpose. The facility would contain laboratories to analyze chemical and radioactive materials typical of potential contaminants that could occur in the environment in the vicinity of the DOE Waste Isolation Pilot Plant (WIPP) site or other locations. The facility also would have bioassay facilities to measure radionuclide levels in the general population and in employees of the WIPP. Operation of the Center would meet the DOE requirement for independent monitoring and assessment of environmental impacts associated with the planned disposal of transuranic waste at the WIPP.« less

  4. Evaluation of continuous air monitor placement in a plutonium facility.

    PubMed

    Whicker, J J; Rodgers, J C; Fairchild, C I; Scripsick, R C; Lopez, R C

    1997-05-01

    Department of Energy appraisers found continuous air monitors at Department of Energy plutonium facilities alarmed less than 30% of the time when integrated room plutonium air concentrations exceeded 500 DAC-hours. Without other interventions, this alarm percentage suggests the possibility that workers could be exposed to high airborne concentrations without continuous air monitor alarms. Past research has shown that placement of continuous air monitors is a critical component in rapid and reliable detection of airborne releases. At Los Alamos National Laboratory and many other Department of Energy plutonium facilities, continuous air monitors have been primarily placed at ventilation exhaust points. The purpose of this study was to evaluate and compare the effectiveness of exhaust register placement of workplace continuous air monitors with other sampling locations. Polydisperse oil aerosols were released from multiple locations in two plutonium laboratories at Los Alamos National Laboratory. An array of laser particle counters positioned in the rooms measured time-resolved aerosol dispersion. Results showed alternative placement of air samplers generally resulted in aerosol detection that was faster, often more sensitive, and equally reliable compared with samplers at exhaust registers.

  5. A Global Perspective of Vaccination of Healthcare Personnel against Measles: Systematic Review

    PubMed Central

    Fiebelkorn, Amy Parker; Seward, Jane F.; Orenstein, Walter

    2015-01-01

    Measles transmission has been well documented in healthcare facilities. Healthcare personnel who are unvaccinated and who lack other evidence of measles immunity put themselves and their patients at risk for measles. We conducted a systematic literature review of measles vaccination policies and their implementation in healthcare personnel, measles seroprevalence among healthcare personnel, measles transmission and disease burden in healthcare settings, and impact/costs incurred by healthcare facilities for healthcare-associated measles transmission. Five database searches yielded 135 relevant articles; 47 additional articles were found through cross-referencing. The risk of acquiring measles is estimated to be 2 to 19 times higher for susceptible healthcare personnel than for the general population. Fifty-three articles published worldwide during 1989–2013 reported measles transmission from patients to healthcare personnel; many of the healthcare personnel were unvaccinated or had unknown vaccination status. Eighteen articles published worldwide during 1982–2013 described examples of transmission from healthcare personnel to patients or to other healthcare personnel. Half of European countries have no measles vaccine policies for healthcare personnel. There is no global policy recommendation for the vaccination of healthcare personnel against measles. Even in countries such as the United States or Finland that have national policies, the recommendations are not uniformly implemented in healthcare facilities. Measles serosusceptibility in healthcare personnel varied widely across studies (median 6.5%, range 0%-46%) but was consistently higher among younger healthcare personnel. Deficiencies in documentation of two doses of measles vaccination or other evidence of immunity among healthcare personnel presents challenges in responding to measles exposures in healthcare settings. Evaluating and containing exposures and outbreaks in healthcare settings can be

  6. Ambient air monitoring of Beijing MSW logistics facilities in 2006.

    PubMed

    Li, Chun-Ping; Li, Guo-Xue; Luo, Yi-Ming; Li, Yan-Fu

    2008-11-01

    In China, "green" integrated waste management methods are being implemented in response to environmental concerns. We measured the air quality at several municipal solid waste (MSW) sites to provide information for the incorporation of logistics facilities within the current integrated waste management system. We monitored ambient air quality at eight MSW collecting stations, five transfer stations, one composting plant, and five disposal sites in Beijing during April 2006. Composite air samples were collected and analyzed for levels of odor, ammonia (NH3), hydrogen sulfide (H2S), total suspended particles (TSPs), carbon monoxide (CO), sulfur dioxide (SO2), and nitrogen dioxide (NO2). The results of our atmospheric monitoring demonstrated that although CO and SO2 were within acceptable emission levels according to ambient standards, levels of H2S, TSP, and NO2 in the ambient air at most MSW logistics facilities far exceeded ambient limits established for China. The primary pollutants in the ambient air at Beijing MSW logistics facilities were H2S, TSPs, NO2, and odor. To improve current environmental conditions at MSW logistics facilities, the Chinese government encourages the separation of biogenic waste from MSW at the source.

  7. Feasibility study of a gamma camera for monitoring nuclear materials in the PRIDE facility

    NASA Astrophysics Data System (ADS)

    Jo, Woo Jin; Kim, Hyun-Il; An, Su Jung; Lee, Chae Young; Song, Han-Kyeol; Chung, Yong Hyun; Shin, Hee-Sung; Ahn, Seong-Kyu; Park, Se-Hwan

    2014-05-01

    The Korea Atomic Energy Research Institute (KAERI) has been developing pyroprocessing technology, in which actinides are recovered together with plutonium. There is no pure plutonium stream in the process, so it has an advantage of proliferation resistance. Tracking and monitoring of nuclear materials through the pyroprocess can significantly improve the transparency of the operation and safeguards. An inactive engineering-scale integrated pyroprocess facility, which is the PyRoprocess Integrated inactive DEmonstration (PRIDE) facility, was constructed to demonstrate engineering-scale processes and the integration of each unit process. the PRIDE facility may be a good test bed to investigate the feasibility of a nuclear material monitoring system. In this study, we designed a gamma camera system for nuclear material monitoring in the PRIDE facility by using a Monte Carlo simulation, and we validated the feasibility of this system. Two scenarios, according to locations of the gamma camera, were simulated using GATE (GEANT4 Application for Tomographic Emission) version 6. A prototype gamma camera with a diverging-slat collimator was developed, and the simulated and experimented results agreed well with each other. These results indicate that a gamma camera to monitor the nuclear material in the PRIDE facility can be developed.

  8. The meteorological monitoring system for the Kennedy Space Center/Cape Canaveral Air Station

    NASA Technical Reports Server (NTRS)

    Dianic, Allan V.

    1994-01-01

    The Kennedy Space Center (KSC) and Cape Canaveral Air Station (CCAS) are involved in many weather-sensitive operations. Manned and unmanned vehicle launches, which occur several times each year, are obvious example of operations whose success and safety are dependent upon favorable meteorological conditions. Other operations involving NASA, Air Force, and contractor personnel, including daily operations to maintain facilities, refurbish launch structures, prepare vehicles for launch, and handle hazardous materials, are less publicized but are no less weather-sensitive. The Meteorological Monitoring System (MMS) is a computer network which acquires, processes, disseminates, and monitors near real-time and forecast meteorological information to assist operational personnel and weather forecasters with the task of minimizing the risk to personnel, materials, and the surrounding population. CLIPS has been integrated into the MMS to provide quality control analysis and data monitoring. This paper describes aspects of the MMS relevant to CLIPS including requirements, actual implementation details, and results of performance testing.

  9. Practical Approaches for Assessment of Daily and Post-discharge Room Disinfection in Healthcare Facilities.

    PubMed

    Deshpande, Abhishek; Donskey, Curtis J

    2017-09-01

    Cleaning and disinfection in healthcare facilities is essential to ensure patient safety. This review examines practical strategies used to assess and improve the effectiveness of daily and post-discharge manual cleaning in healthcare facilities. Effective implementation of cleaning interventions requires objective monitoring of staff performance with regular feedback on performance. Use of fluorescent markers to assess thoroughness of cleaning and measurement of residual ATP can provide rapid and objective feedback to personnel and have been associated with improved cleaning. Direct observation of cleaning and interviews with front-line staff are useful to identify variations and deficiencies in practice that may not be detected by other methods. Although not recommended for routine monitoring, cultures can be helpful for outbreak investigations. Monitoring and feedback can be effective in improving cleaning and disinfection in healthcare facilities. Ongoing commitment within institutions is needed to sustain successful cleaning and disinfection programs.

  10. 44 CFR 312.5 - Personnel.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ....5 Emergency Management and Assistance FEDERAL EMERGENCY MANAGEMENT AGENCY, DEPARTMENT OF HOMELAND SECURITY PREPAREDNESS USE OF CIVIL DEFENSE PERSONNEL, MATERIALS, AND FACILITIES FOR NATURAL DISASTER... of specific programs, through payment of salaries and benefits of State and local civil defense staff...

  11. 44 CFR 312.5 - Personnel.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ....5 Emergency Management and Assistance FEDERAL EMERGENCY MANAGEMENT AGENCY, DEPARTMENT OF HOMELAND SECURITY PREPAREDNESS USE OF CIVIL DEFENSE PERSONNEL, MATERIALS, AND FACILITIES FOR NATURAL DISASTER... of specific programs, through payment of salaries and benefits of State and local civil defense staff...

  12. 44 CFR 312.5 - Personnel.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ....5 Emergency Management and Assistance FEDERAL EMERGENCY MANAGEMENT AGENCY, DEPARTMENT OF HOMELAND SECURITY PREPAREDNESS USE OF CIVIL DEFENSE PERSONNEL, MATERIALS, AND FACILITIES FOR NATURAL DISASTER... of specific programs, through payment of salaries and benefits of State and local civil defense staff...

  13. 44 CFR 312.5 - Personnel.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ....5 Emergency Management and Assistance FEDERAL EMERGENCY MANAGEMENT AGENCY, DEPARTMENT OF HOMELAND SECURITY PREPAREDNESS USE OF CIVIL DEFENSE PERSONNEL, MATERIALS, AND FACILITIES FOR NATURAL DISASTER... of specific programs, through payment of salaries and benefits of State and local civil defense staff...

  14. Capability challenges of facility management (FM) personnel toward sustainability agenda

    NASA Astrophysics Data System (ADS)

    Halim, Ahmad Ilyas Ahmad; Sarpin, Norliana; Kasim, Narimah Binti; Zainal, Rozlin Binti

    2017-10-01

    The industries business play a significant role to contribute toward economic growth in develop and developing country. However, they always face serious problems such as time overrun, waste generation, and cost overrun during their operation and maintenance. Traditional practice is found unable to control that situation. These challenges accent the need for practitioners to rethink and improve their process management. This show that industries business has major potential when applying sustainable development by focusing on three pillars (economic, environment, and social). By adopting sustainability, it can reduce energy consumption and waste, while increasing productivity, financial return and corporate standing in community. FM personnel are most suitable position to lead organizations toward sustainability implementation. However, lack of skill and capability among FM personnel to achieve sustainable goal had become barrier that need to overcome. This paper focus to identify capability challenges of FM personnel toward sustainability. A multiple researches were conducted and data were gathered through literature review from previous studies.

  15. Real-time Stack Monitoring at the BaTek Medical Isotope Production Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McIntyre, Justin I.; Agusbudiman, A.; Cameron, Ian M.

    2016-04-01

    Radioxenon emissions from radiopharmaceutical production are a major source of background concentrations affecting the radioxenon detection systems of the International Monitoring System (IMS). Collection of real-time emissions data from production facilities makes it possible to screen out some medical isotope signatures from the IMS radioxenon data sets. This paper describes an effort to obtain and analyze real-time stack emissions data with the design, construction and installation of a small stack monitoring system developed by a joint CTBTO-IDC, BATAN, and PNNL team at the BaTek medical isotope production facility near Jakarta, Indonesia.

  16. Summary report on the attempted monitoring of Highway 20 stormwater MP 1.11-2.31.

    DOT National Transportation Integrated Search

    2005-01-01

    As part of SPR-335 Water Quality Facility Investigation, an attempt was made to : exercise the UIC Stormwater Monitoring Plan developed for Highway 20 from MP 1.11 : to 2.31 in eastern Bend, Oregon. The intention was to use ODOT personnel : headquart...

  17. 44 CFR 312.5 - Personnel.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Emergency Management and Assistance FEDERAL EMERGENCY MANAGEMENT AGENCY, DEPARTMENT OF HOMELAND SECURITY PREPAREDNESS USE OF CIVIL DEFENSE PERSONNEL, MATERIALS, AND FACILITIES FOR NATURAL DISASTER PURPOSES § 312.5... programs, through payment of salaries and benefits of State and local civil defense staff, and the payment...

  18. 7 CFR 56.77 - Health and hygiene of personnel.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 3 2012-01-01 2012-01-01 false Health and hygiene of personnel. 56.77 Section 56.77 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards... EGGS Grading of Shell Eggs Facility Requirements § 56.77 Health and hygiene of personnel. (a) No person...

  19. 7 CFR 56.77 - Health and hygiene of personnel.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Health and hygiene of personnel. 56.77 Section 56.77 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards... EGGS Grading of Shell Eggs Facility Requirements § 56.77 Health and hygiene of personnel. (a) No person...

  20. 7 CFR 56.77 - Health and hygiene of personnel.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Health and hygiene of personnel. 56.77 Section 56.77 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards... EGGS Grading of Shell Eggs Facility Requirements § 56.77 Health and hygiene of personnel. (a) No person...

  1. Feasibility study: Assess the feasibility of siting a monitored retrievable storage facility. Phase 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    King, J.W.

    1993-08-01

    The purpose of phase one of this study are: To understand the waste management system and a monitored retrievable storage facility; and to determine whether the applicant has real interest in pursuing the feasibility assessment process. Contents of this report are: Generating electric power; facts about exposure to radiation; handling storage, and transportation techniques; description of a proposed monitored retrievable storage facility; and benefits to be received by host jurisdiction.

  2. Tropical skin diseases in British military personnel.

    PubMed

    Bailey, Mark S

    2013-09-01

    Skin complaints are common in travellers to foreign countries and are responsible for up to 25% of medical consultations by military personnel during deployments in the tropics. They also have relatively high rates of field hospital admission, medical evacuation and referral to UK Role 4 healthcare facilities. Non-infectious tropical skin diseases include sunburn, heat rash, arthropod bites, venomous bites, contact dermatitis and phytophotodermatitis. During tropical deployments skin infections that commonly occur in military personnel may become more frequent, severe and difficult to treat. Several systemic tropical infections have cutaneous features that can be useful in making early diagnoses. Tropical skin infections such as cutaneous larva migrans, cutaneous myiasis, cutaneous leishmaniasis and leprosy do occur in British troops and require specialist clinical management. This illustrated review focuses on the most significant tropical skin diseases that have occurred in British military personnel in recent years. Clinical management of these conditions on deployments would be improved and medical evacuations could be reduced if a military dermatology 'reach-back' service (including a telemedicine facility) was available.

  3. A Personnel System for People.

    ERIC Educational Resources Information Center

    Smith, Robin C.

    A description is provided of the personnel subsystem of the computerized School Information System (SIS) developed by the Department of Advance Planning and Development of the Montgomery County, Maryland Public Schools. Other subsystems of SIS are being developed to deal with data relating to pupils, material, finance and facilities. The first…

  4. Job attitudes of airway facilities personnel.

    DOT National Transportation Integrated Search

    1977-08-01

    A total of 2,366 employees of the Airway Facilities (AF) Service responded to a detailed questionnaire concerning job satisfaction and such factors as salary, shift schedule, workload, and geographic location. : In general, AF employees reported sati...

  5. Beam Position Monitoring in the CSU Accelerator Facility

    NASA Astrophysics Data System (ADS)

    Einstein, Joshua; Vankeuren, Max; Watras, Stephen

    2014-03-01

    A Beam Position Monitoring (BPM) system is an integral part of an accelerator beamline, and modern accelerators can take advantage of newer technologies and designs when creating a BPM system. The Colorado State University (CSU) Accelerator Facility will include four stripline detectors mounted around the beamline, a low-noise analog front-end, and digitization and interface circuitry. The design will support a sampling rate greater than 10 Hz and sub-100 μm accuracy.

  6. Activities of the US-Japan Safety Monitor Joint Working Group

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Richard L. Savercool; Lee C. Cadwallader

    2004-09-01

    This paper documents the activities of the US-Japan exchange in the area of personnel safety at magnetic and laser fusion experiments. A near-miss event with a visiting scientist to the US in 1992 was the impetus for forming the Joint Working Group on Fusion Safety. This exchnge has been under way for over ten years and has provided many safety insights for both US and Japanese facility personnel at national institutes and at universities. The background and activities of the Joint Working Group are described, including the facilities that have been visited for safety walkthroughs, the participants from both countries,more » and the main safety issues examined during visits. Based on these visits, some operational safety ideas to enhance experiment safety are given. The near-term future plans of the Safety Monitor Joint Working group are also discussed.« less

  7. Eye lens monitoring for interventional radiology personnel: dosemeters, calibration and practical aspects of H p (3) monitoring. A 2015 review.

    PubMed

    Carinou, Eleftheria; Ferrari, Paolo; Bjelac, Olivera Ciraj; Gingaume, Merce; Merce, Marta Sans; O'Connor, Una

    2015-09-01

    A thorough literature review about the current situation on the implementation of eye lens monitoring has been performed in order to provide recommendations regarding dosemeter types, calibration procedures and practical aspects of eye lens monitoring for interventional radiology personnel. Most relevant data and recommendations from about 100 papers have been analysed and classified in the following topics: challenges of today in eye lens monitoring; conversion coefficients, phantoms and calibration procedures for eye lens dose evaluation; correction factors and dosemeters for eye lens dose measurements; dosemeter position and influence of protective devices. The major findings of the review can be summarised as follows: the recommended operational quantity for the eye lens monitoring is H p (3). At present, several dosemeters are available for eye lens monitoring and calibration procedures are being developed. However, in practice, very often, alternative methods are used to assess the dose to the eye lens. A summary of correction factors found in the literature for the assessment of the eye lens dose is provided. These factors can give an estimation of the eye lens dose when alternative methods, such as the use of a whole body dosemeter, are used. A wide range of values is found, thus indicating the large uncertainty associated with these simplified methods. Reduction factors from most common protective devices obtained experimentally and using Monte Carlo calculations are presented. The paper concludes that the use of a dosemeter placed at collar level outside the lead apron can provide a useful first estimate of the eye lens exposure. However, for workplaces with estimated annual equivalent dose to the eye lens close to the dose limit, specific eye lens monitoring should be performed. Finally, training of the involved medical staff on the risks of ionising radiation for the eye lens and on the correct use of protective systems is strongly recommended.

  8. 44 CFR 302.7 - Use of funds, materials, supplies, equipment, and personnel.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... use of civil defense personnel, organizational equipment, materials, and facilities, in preparation..., supplies, equipment, and personnel. 302.7 Section 302.7 Emergency Management and Assistance FEDERAL... EMERGENCY MANAGEMENT ASSISTANCE PROGRAM (EMA) § 302.7 Use of funds, materials, supplies, equipment, and...

  9. Absolute Sea-level Monitoring and Altimeter Calibration Facility at Gavdos, Crete, Greece

    NASA Astrophysics Data System (ADS)

    Pavlis, E. C.

    2002-12-01

    We introduce the recently instrumented mean sea level (MSL) monitoring facility on western Crete and the isle of Gavdos. We will focus on the altimeter calibration aspect of the facility, in particular, its application to the JASON mission. The Eastern Mediterranean area is one of great interest for its intense tectonic activity as well as for its regional oceanography. Recent observations have convincingly demonstrated the importance of that area for the regional meteorological and climatologic changes. Tide-gauge monitoring with continuous GPS has gained importance lately since tectonics contaminate the inferred sea level variations, and a global network of tide-gauges with long historical records can be used as satellite altimeter calibration sites (e.g. TOPEX/POSEIDON, GFO, JASON-1, ENVISAT, etc.). This is at present a common IOC-GLOSS-IGS effort, already underway (TIGA), and our facility is part of it. Crete hosts two of the oldest tide-gauges in the regional network and our project will further expand it to the south with a new site on the isle of Gavdos, the southernmost European parcel of land. One component of our "GAVDOS" project is the repeated occupation of two already in existence tide-gauge sites at Souda Bay and Heraklion, and their tie to the new facility. We show here initial results from positioning of these sites and some of the available tidal records. Gavdos is situated under a ground-track crossing point of the original T/P and present JASON-1 orbits. It is an ideal calibration site if the tectonic motions are monitored precisely and continuously. The facility hosts in addition to the tide gauges: GPS and DORIS beacons for positioning, transponders for direct calibration, water vapor radiometers and solar spectrometers, GPS-loaded buoys, airborne surveys with gravimeters and laser profiling lidars, transportable laser ranging systems, etc., to ensure the best possible and most reliable results.

  10. 13. Historic view of Building 100 control room, showing personnel ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    13. Historic view of Building 100 control room, showing personnel with data recording instrumentation. 1957. On file at NASA Plumbrook Research Facility, Sandusky, Ohio. NASA photo number C-46211. - Rocket Engine Testing Facility, GRC Building No. 100, NASA Glenn Research Center, Cleveland, Cuyahoga County, OH

  11. A button - type beam position monitor design for TARLA facility

    NASA Astrophysics Data System (ADS)

    Gündoǧan, M. Tural; Kaya, ć.; Yavaş, Ö.

    2016-03-01

    Turkish Accelerator and Radiation Laboratory in Ankara (TARLA) facility is proposed as an IR FEL and Bremsstrahlung facility as the first facility of Turkish Accelerator Center (TAC). TARLA is essentially proposed to generate oscillator mode FEL in 3-250 microns wavelengths range, will consist of normal conducting injector system with 250 keV beam energy, two superconducting RF accelerating modules in order to accelerate the beam 15-40 MeV. The TARLA facility is expected to provide two modes, Continuous wave (CW) and pulsed mode. Longitudinal electron bunch length will be changed between 1 and 10 ps. The bunch charge will be limited by 77pC. The design of the Button-type Beam Position Monitor for TARLA IR FEL is studied to operate in 1.3 GHz. Mechanical antenna design and simulations are completed considering electron beam parameters of TARLA. Ansoft HFSS and CST Particle Studio is used to compare with results of simulations.

  12. 30 CFR 254.42 - Exercises for your response personnel and equipment.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 2 2013-07-01 2013-07-01 false Exercises for your response personnel and... COAST LINE Related Requirements for Outer Continental Shelf Facilities § 254.42 Exercises for your response personnel and equipment. (a) You must exercise your entire response plan at least once every 3...

  13. Monitoring Exposure to Ebola and Health of U.S. Military Personnel Deployed in Support of Ebola Control Efforts - Liberia, October 25, 2014-February 27, 2015.

    PubMed

    Cardile, Anthony P; Murray, Clinton K; Littell, Christopher T; Shah, Neel J; Fandre, Matthew N; Drinkwater, Dennis C; Markelz, Brian P; Vento, Todd J

    2015-07-03

    In response to the unprecedented Ebola virus disease (Ebola) outbreak in West Africa, the U.S. government deployed approximately 2,500 military personnel to support the government of Liberia. Their primary missions were to construct Ebola treatment units (ETUs), train health care workers to staff ETUs, and provide laboratory testing capacity for Ebola. Service members were explicitly prohibited from engaging in activities that could result in close contact with an Ebola-infected patient or coming in contact with the remains of persons who had died from unknown causes. Military units performed twice-daily monitoring of temperature and review of exposures and symptoms ("unit monitoring") on all persons throughout deployment, exit screening at the time of departure from Liberia, and post-deployment monitoring for 21 days at segregated, controlled monitoring areas on U.S. military installations. A total of 32 persons developed a fever during deployment from October 25, 2014, through February 27, 2015; none had a known Ebola exposure or developed Ebola infection. Monitoring of all deployed service members revealed no Ebola exposures or infections. Given their activity restrictions and comprehensive monitoring while deployed to Liberia, U.S. military personnel constitute a unique population with a lower risk for Ebola exposure compared with those working in the country without such measures.

  14. Open-Path Hydrocarbon Laser Sensor for Oil and Gas Facility Monitoring

    EPA Science Inventory

    This poster reports on an experimental prototype open-path laser absorption sensor for measurement of unspeciated hydrocarbons for oil and gas production facility fence-line monitoring. Such measurements may be useful to meet certain state regulations, and enable advanced leak d...

  15. Approach to the vadose zone monitoring in hazardous and solid waste disposal facilities

    NASA Astrophysics Data System (ADS)

    Twardowska, Irena

    2004-03-01

    In the solid waste (SW)disposal sites, in particular at the unlined facilities, at the remediated or newly-constructed units equipped with novel protective/reactive permeable barriers or at lined facilities with leachate collection systems that are prone to failure, the vadose zone monitoring should comprise besides the natural soil layer beneath the landfill, also the anthropogenic vadose zone, i.e. the waste layer and pore solutions in the landfill. The vadose zone screening along the vertical profile of SW facilities with use of direct invasive soil-core and soil-pore liquid techniques shows vertical downward redistribution of inorganic (macroconstituents and heavy metals) and organic (PAHs) contaminant loads in water infiltrating through the waste layer. These loads can make ground water down-gradient of the dump unfit for any use. To avoid damage of protective/reactive permeable barriers and liners, an installation of stationary monitoring systems along the waste layer profile during the construction of a landfill, which are amenable to generate accurate data and information in a near-real time should be considered including:(i) permanent samplers of pore solution, with a periodic pump-induced transport of collected solution to the surface, preferably with instant field measurements;(ii)chemical sensors with continuous registration of critical parameters. These techniques would definitely provide an early alert in case when the chemical composition of pore solution percolating downward the waste profile shows unfavorable transformations, which indicate an excessive contaminant load approaching ground water. The problems concerning invasive and stationary monitoring of the vadose zone in SW disposal facilities will be discussed at the background of results of monitoring data and properties of permeable protective/reactive barriers considered for use.

  16. Statistical analysis of environmental monitoring data: does a worst case time for monitoring clean rooms exist?

    PubMed

    Cundell, A M; Bean, R; Massimore, L; Maier, C

    1998-01-01

    To determine the relationship between the sampling time of the environmental monitoring, i.e., viable counts, in aseptic filling areas and the microbial count and frequency of alerts for air, surface and personnel microbial monitoring, statistical analyses were conducted on 1) the frequency of alerts versus the time of day for routine environmental sampling conducted in calendar year 1994, and 2) environmental monitoring data collected at 30-minute intervals during routine aseptic filling operations over two separate days in four different clean rooms with multiple shifts and equipment set-ups at a parenteral manufacturing facility. Statistical analyses showed, except for one floor location that had significantly higher number of counts but no alert or action level samplings in the first two hours of operation, there was no relationship between the number of counts and the time of sampling. Further studies over a 30-day period at the floor location showed no relationship between time of sampling and microbial counts. The conclusion reached in the study was that there is no worst case time for environmental monitoring at that facility and that sampling any time during the aseptic filling operation will give a satisfactory measure of the microbial cleanliness in the clean room during the set-up and aseptic filling operation.

  17. 5 CFR 430.306 - Monitoring performance.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Monitoring performance. 430.306 Section 430.306 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS PERFORMANCE MANAGEMENT Managing Senior Executive Performance § 430.306 Monitoring performance. (a) Supervisors must...

  18. 5 CFR 430.306 - Monitoring performance.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 5 Administrative Personnel 1 2013-01-01 2013-01-01 false Monitoring performance. 430.306 Section 430.306 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS PERFORMANCE MANAGEMENT Managing Senior Executive Performance § 430.306 Monitoring performance. (a) Supervisors must...

  19. 5 CFR 430.306 - Monitoring performance.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 5 Administrative Personnel 1 2011-01-01 2011-01-01 false Monitoring performance. 430.306 Section 430.306 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS PERFORMANCE MANAGEMENT Managing Senior Executive Performance § 430.306 Monitoring performance. (a) Supervisors must...

  20. 5 CFR 430.306 - Monitoring performance.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 5 Administrative Personnel 1 2014-01-01 2014-01-01 false Monitoring performance. 430.306 Section 430.306 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS PERFORMANCE MANAGEMENT Managing Senior Executive Performance § 430.306 Monitoring performance. (a) Supervisors must...

  1. 5 CFR 430.306 - Monitoring performance.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 5 Administrative Personnel 1 2012-01-01 2012-01-01 false Monitoring performance. 430.306 Section 430.306 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS PERFORMANCE MANAGEMENT Managing Senior Executive Performance § 430.306 Monitoring performance. (a) Supervisors must...

  2. Ground Water Monitoring Requirements for Hazardous Waste Treatment, Storage and Disposal Facilities

    EPA Pesticide Factsheets

    The groundwater monitoring requirements for hazardous waste treatment, storage and disposal facilities (TSDFs) are just one aspect of the Resource Conservation and Recovery Act (RCRA) hazardous waste management strategy for protecting human health and the

  3. A control system of a mini survey facility for photometric monitoring

    NASA Astrophysics Data System (ADS)

    Tsutsui, Hironori; Yanagisawa, Kenshi; Izumiura, Hideyuki; Shimizu, Yasuhiro; Hanaue, Takumi; Ita, Yoshifusa; Ichikawa, Takashi; Komiyama, Takahiro

    2016-08-01

    We have built a control system for a mini survey facility dedicated to photometric monitoring of nearby bright (K<5) stars in the near-infrared region. The facility comprises a 4-m-diameter rotating dome and a small (30-mm aperture) wide-field (5 × 5 sq. deg. field of view) infrared (1.0-2.5 microns) camera on an equatorial fork mount, as well as power sources and other associated equipment. All the components other than the camera are controlled by microcomputerbased I/O boards that were developed in-house and are in many of the open-use instruments in our observatory. We present the specifications and configuration of the facility hardware, as well as the structure of its control software.

  4. Facilities Planning Conference for Community-Junior College State-Level Personnel.

    ERIC Educational Resources Information Center

    Florida Univ., Gainesville. Inst. of Higher Education.

    This report on planning and developing facilities for community-junior colleges includes papers presented at a conference for state-level facility planners. The meeting covered the following areas: (1) development of physical facilities responsive to educational programs and community needs; (2) efficient use of existing facilities through…

  5. 42 CFR 136.110 - Facilities construction.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Facilities construction. 136.110 Section 136.110... Facilities and Services § 136.110 Facilities construction. In addition to other requirements of this subpart..., clinic, health station or quarters for housing personnel associated with such facilities, must in its...

  6. 30 CFR 57.20008 - Toilet facilities.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Toilet facilities. 57.20008 Section 57.20008....20008 Toilet facilities. (a) Toilet facilities shall be provided at locations that are compatible with the mine operations and that are readily accessible to mine personnel. (b) The facilities shall be...

  7. A semi-automated method of monitoring dam passage of American Eels Anguilla rostrata

    USGS Publications Warehouse

    Welsh, Stuart A.; Aldinger, Joni L.

    2014-01-01

    Fish passage facilities at dams have become an important focus of fishery management in riverine systems. Given the personnel and travel costs associated with physical monitoring programs, automated or semi-automated systems are an attractive alternative for monitoring fish passage facilities. We designed and tested a semi-automated system for eel ladder monitoring at Millville Dam on the lower Shenandoah River, West Virginia. A motion-activated eel ladder camera (ELC) photographed each yellow-phase American Eel Anguilla rostrata that passed through the ladder. Digital images (with date and time stamps) of American Eels allowed for total daily counts and measurements of eel TL using photogrammetric methods with digital imaging software. We compared physical counts of American Eels with camera-based counts; TLs obtained with a measuring board were compared with TLs derived from photogrammetric methods. Data from the ELC were consistent with data obtained by physical methods, thus supporting the semi-automated camera system as a viable option for monitoring American Eel passage. Time stamps on digital images allowed for the documentation of eel passage time—data that were not obtainable from physical monitoring efforts. The ELC has application to eel ladder facilities but can also be used to monitor dam passage of other taxa, such as crayfishes, lampreys, and water snakes.

  8. Remote monitoring of a Fire Protection System

    NASA Astrophysics Data System (ADS)

    Bauman, Steven; Vermeulen, Tom; Roberts, Larry; Matsushige, Grant; Gajadhar, Sarah; Taroma, Ralph; Elizares, Casey; Arruda, Tyson; Potter, Sharon; Hoffman, James

    2011-03-01

    Some years ago CFHT proposed developing a Remote Observing Environment aimed at producing Science Observations at their Observatory Facility on Mauna Kea from their Headquarters facility in Waimea, HI. This Remote Observing Project commonly referred to as OAP (Observatory Automation Project) was completed at the end of January 2011 and has been providing the majority of Science Data since. My poster will discuss the upgrades to the existing fire alarm protection system. With no one at the summit during nightly operations, the observatory facility required automated monitoring of the facility for safety to personnel and equipment in the case of a fire. An addressable analog fire panel was installed which utilizes digital communication protocol (DCP), intelligent communication with other devices, and an RS-232 interface which provides feedback and real-time monitoring of the system. Using the interface capabilities of the panel, it provides notifications when heat detectors, smoke sensors, manual pull stations, or the main observatory computer room fire suppression system has been activated. The notifications are sent out as alerts to staff in the form of test massages and emails and the observing control GUI interface alerts the remote telescope operator with a map showing the location of the fire occurrence and type of device that has been triggered. And all of this was accomplished without the need for an outside vendor to monitor the system and facilitate warnings or notifications regarding the system.

  9. Design and characterization of an irradiation facility with real-time monitoring

    NASA Astrophysics Data System (ADS)

    Braisted, Jonathan David

    Radiation causes performance degradation in electronics by inducing atomic displacements and ionizations. While radiation hardened components are available, non-radiation hardened electronics can be preferable because they are generally more compact, require less power, and less expensive than radiation tolerant equivalents. It is therefore important to characterize the performance of electronics, both hardened and non-hardened, to prevent costly system or mission failures. Radiation effects tests for electronics generally involve a handful of step irradiations, leading to poorly-resolved data. Step irradiations also introduce uncertainties in electrical measurements due to temperature annealing effects. This effect may be intensified if the time between exposure and measurement is significant. Induced activity in test samples also complicates data collection of step irradiated test samples. The University of Texas at Austin operates a 1.1 MW Mark II TRIGA research reactor. An in-core irradiation facility for radiation effects testing with a real-time monitoring capability has been designed for the UT TRIGA reactor. The facility is larger than any currently available non-central location in a TRIGA, supporting testing of larger electronic components as well as other in-core irradiation applications requiring significant volume such as isotope production or neutron transmutation doping of silicon. This dissertation describes the design and testing of the large in-core irradiation facility and the experimental campaign developed to test the real-time monitoring capability. This irradiation campaign was performed to test the real-time monitoring capability at various reactor power levels. The device chosen for characterization was the 4N25 general-purpose optocoupler. The current transfer ratio, which is an important electrical parameter for optocouplers, was calculated as a function of neutron fluence and gamma dose from the real-time voltage measurements. The

  10. Decontamination Workshop for Emergency Responding Personnel How Clean is Clean Enough 12-14 September 2007

    DTIC Science & Technology

    2008-09-01

    refers to a Medical Treatment Facility (MTF), can we assume that disrobing is sufficient? Is it possible to develop specific site clearance criteria ...o First responders , medical personnel, and the HAZMAT team o Incident Commanders o Public information officials o Hospitals and hospital networks ...clean personnel (both victims and first responders ) need to be when they are released from the incident site (or treatment facility for those that make

  11. 30 CFR 56.20008 - Toilet facilities.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Toilet facilities. 56.20008 Section 56.20008... Toilet facilities. (a) Toilet facilities shall be provided at locations that are compatible with the mine operations and that are readily accessible to mine personnel. (b) The facilities shall be kept clean and...

  12. 15 CFR 716.8 - On-site monitoring of Schedule 1 facilities.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 15 Commerce and Foreign Trade 2 2010-01-01 2010-01-01 false On-site monitoring of Schedule 1 facilities. 716.8 Section 716.8 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS...

  13. 15 CFR 716.8 - On-site monitoring of Schedule 1 facilities.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 15 Commerce and Foreign Trade 2 2011-01-01 2011-01-01 false On-site monitoring of Schedule 1 facilities. 716.8 Section 716.8 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS...

  14. Assessment of an application for touchscreen devices to record calving-related events in dairy herds and monitor personnel performance.

    PubMed

    Barragan, A A; Workman, J D; Bas, S; Proudfoot, K L; Schuenemann, G M

    2016-07-01

    The objectives of the present study were to assess (1) the effectiveness of a calving training workshop and an application (app) for touchscreen devices to capture calving-related events, and (2) personnel compliance with calving protocols (time from birth to feeding of first colostrum and time that cows spent in labor). Calving personnel (n=23) from 5 large dairy farms (range: 800-10,000 cows) participated in the study. Participants received training through an on-farm workshop regarding calving management practices and functioning of the app before recording calving-related events. Pre- and posttest evaluations were administered to each participant to measure their knowledge gain and satisfaction with the workshop. Calving personnel recorded calving-related events (n=323) using the app for 7 d following training. Furthermore, the records collected with the app were used to assess missing and incorrect data and calving personnel compliance with calving management protocols (recording time that cows spent in labor and timing of feeding first colostrum to calves). Calving personnel reported that the information provided during the training was relevant (agree=14.3% and strongly agree=85.7%) and of great immediate use (agree=33.3% and strongly agree=66.7%). The presented materials and hands-on demonstrations substantially increased the knowledge level of the attendees (by 23.7 percentage points from pre- to posttest scores). The follow-up assessment with participants revealed that the app was easy to use (91.3%) and that they would continue to use it (100%). Frequency of incorrect (r=0.77) or missing (r=0.76) data was positively correlated with calving:personnel ratio. Furthermore, calving personnel compliance with calving protocols was significantly different within and between herds. These results substantiated the great variation in compliance with calving management protocols within and between dairy farms. Furthermore, the app may serve as a tool to monitor

  15. Monitoring the implementation of the WHO Global Code of Practice on the International Recruitment of Health Personnel.

    PubMed

    Siyam, Amani; Zurn, Pascal; Rø, Otto Christian; Gedik, Gulin; Ronquillo, Kenneth; Joan Co, Christine; Vaillancourt-Laflamme, Catherine; dela Rosa, Jennifer; Perfilieva, Galina; Dal Poz, Mario Roberto

    2013-11-01

    To present the findings of the first round of monitoring of the global implementation of the WHO Global Code of Practice on the International Recruitment of Health Personnel ("the Code"), a voluntary code adopted in 2010 by all 193 Member States of the World Health Organization (WHO). WHO requested that its Member States designate a national authority for facilitating information exchange on health personnel migration and the implementation of the Code. Each designated authority was then sent a cross-sectional survey with 15 questions on a range of topics pertaining to the 10 articles included in the Code. A national authority was designated by 85 countries. Only 56 countries reported on the status of Code implementation. Of these, 37 had taken steps towards implementing the Code, primarily by engaging relevant stakeholders. In 90% of countries, migrant health professionals reportedly enjoy the same legal rights and responsibilities as domestically trained health personnel. In the context of the Code, cooperation in the area of health workforce development goes beyond migration-related issues. An international comparative information base on health workforce mobility is needed but can only be developed through a collaborative, multi-partnered approach. Reporting on the implementation of the Code has been suboptimal in all but one WHO region. Greater collaboration among state and non-state actors is needed to raise awareness of the Code and reinforce its relevance as a potent framework for policy dialogue on ways to address the health workforce crisis.

  16. A passive RFID-based location system for personnel and asset monitoring.

    PubMed

    Hsiao, Rong-Shue; Kao, Chun-Hao; Chen, Tian-Xiang; Chen, Jui-Lun

    2018-01-01

    Typical radio frequency identification (RFID) access control system can be ineffective if an unauthorized person tailgates an authorized person through an access area. To propose a system by using indoor locating and tracking techniques address this problem, which is to prevent unauthorized Alzheimer's and dementia patients from getting lost including by tailgating. To achieve accurate target location, passive RFID deployment strategy is studied and a fingerprinting based passive RFID localization algorithm is proposed. The proposed system was evaluated in a building environment to simulate the performance of access control. RFID reader was installed on ceiling near the access area and tags were stitched on both shoulders of the experiment subject's garments. The probability of the error distance within 0.3 m achieved 97% in the warning area; the location precision achieved 97% within 0.4 m in the monitoring area. The result showed that if an unauthorized person enters the restricted area, the system can initiate an alert signal accurately. Therefore, the proposed system is very suitable to be used in nursing home or hospital to prevent unauthorized personnel and assets entering/exiting a confined location.

  17. 5 CFR 723.150 - Program accessibility: Existing facilities.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... facilities. 723.150 Section 723.150 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT (CONTINUED) CIVIL... ACTIVITIES CONDUCTED BY THE OFFICE OF PERSONNEL MANAGEMENT § 723.150 Program accessibility: Existing... would result in a fundamental alteration in the nature of a program or activity or in undue financial...

  18. 16 CFR Figures 1 and 2 to Part 1204 - Suggested Instrumentation for Current Monitoring Device and High Voltage Facility

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 16 Commercial Practices 2 2012-01-01 2012-01-01 false Suggested Instrumentation for Current Monitoring Device and High Voltage Facility 1 Figures 1 and 2 to Part 1204 Commercial Practices CONSUMER... Instrumentation for Current Monitoring Device and High Voltage Facility EC03OC91.008 ...

  19. 16 CFR Figures 1 and 2 to Part 1204 - Suggested Instrumentation for Current Monitoring Device and High Voltage Facility

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 16 Commercial Practices 2 2014-01-01 2014-01-01 false Suggested Instrumentation for Current Monitoring Device and High Voltage Facility 1 Figures 1 and 2 to Part 1204 Commercial Practices CONSUMER... Instrumentation for Current Monitoring Device and High Voltage Facility EC03OC91.008 ...

  20. 16 CFR Figures 1 and 2 to Part 1204 - Suggested Instrumentation for Current Monitoring Device and High Voltage Facility

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 16 Commercial Practices 2 2013-01-01 2013-01-01 false Suggested Instrumentation for Current Monitoring Device and High Voltage Facility 1 Figures 1 and 2 to Part 1204 Commercial Practices CONSUMER... Instrumentation for Current Monitoring Device and High Voltage Facility EC03OC91.008 ...

  1. 30 CFR 56.20008 - Toilet facilities.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... operations and that are readily accessible to mine personnel. (b) The facilities shall be kept clean and sanitary. Separate toilet facilities shall be provided for each sex except where toilet rooms will be...

  2. 30 CFR 56.20008 - Toilet facilities.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... operations and that are readily accessible to mine personnel. (b) The facilities shall be kept clean and sanitary. Separate toilet facilities shall be provided for each sex except where toilet rooms will be...

  3. 30 CFR 56.20008 - Toilet facilities.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... operations and that are readily accessible to mine personnel. (b) The facilities shall be kept clean and sanitary. Separate toilet facilities shall be provided for each sex except where toilet rooms will be...

  4. 30 CFR 56.20008 - Toilet facilities.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... operations and that are readily accessible to mine personnel. (b) The facilities shall be kept clean and sanitary. Separate toilet facilities shall be provided for each sex except where toilet rooms will be...

  5. Wearable Sensors for Remote Health Monitoring.

    PubMed

    Majumder, Sumit; Mondal, Tapas; Deen, M Jamal

    2017-01-12

    Life expectancy in most countries has been increasing continually over the several few decades thanks to significant improvements in medicine, public health, as well as personal and environmental hygiene. However, increased life expectancy combined with falling birth rates are expected to engender a large aging demographic in the near future that would impose significant  burdens on the socio-economic structure of these countries. Therefore, it is essential to develop cost-effective, easy-to-use systems for the sake of elderly healthcare and well-being. Remote health monitoring, based on non-invasive and wearable sensors, actuators and modern communication and information technologies offers an efficient and cost-effective solution that allows the elderly to continue to live in their comfortable home environment instead of expensive healthcare facilities. These systems will also allow healthcare personnel to monitor important physiological signs of their patients in real time, assess health conditions and provide feedback from distant facilities. In this paper, we have presented and compared several low-cost and non-invasive health and activity monitoring systems that were reported in recent years. A survey on textile-based sensors that can potentially be used in wearable systems is also presented. Finally, compatibility of several communication technologies as well as future perspectives and research challenges in remote monitoring systems will be discussed.

  6. Wearable Sensors for Remote Health Monitoring

    PubMed Central

    Majumder, Sumit; Mondal, Tapas; Deen, M. Jamal

    2017-01-01

    Life expectancy in most countries has been increasing continually over the several few decades thanks to significant improvements in medicine, public health, as well as personal and environmental hygiene. However, increased life expectancy combined with falling birth rates are expected to engender a large aging demographic in the near future that would impose significant  burdens on the socio-economic structure of these countries. Therefore, it is essential to develop cost-effective, easy-to-use systems for the sake of elderly healthcare and well-being. Remote health monitoring, based on non-invasive and wearable sensors, actuators and modern communication and information technologies offers an efficient and cost-effective solution that allows the elderly to continue to live in their comfortable home environment instead of expensive healthcare facilities. These systems will also allow healthcare personnel to monitor important physiological signs of their patients in real time, assess health conditions and provide feedback from distant facilities. In this paper, we have presented and compared several low-cost and non-invasive health and activity monitoring systems that were reported in recent years. A survey on textile-based sensors that can potentially be used in wearable systems is also presented. Finally, compatibility of several communication technologies as well as future perspectives and research challenges in remote monitoring systems will be discussed. PMID:28085085

  7. 16 CFR Figures 1 and 2 to Part 1204 - Suggested Instrumentation for Current Monitoring Device and High Voltage Facility

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Monitoring Device and High Voltage Facility 1 Figures 1 and 2 to Part 1204 Commercial Practices CONSUMER... CITIZENS BAND BASE STATION ANTENNAS Pt. 1204, Figs. 1, 2 Figures 1 and 2 to Part 1204—Suggested Instrumentation for Current Monitoring Device and High Voltage Facility EC03OC91.008 ...

  8. 16 CFR Figures 1 and 2 to Part 1204 - Suggested Instrumentation for Current Monitoring Device and High Voltage Facility

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Monitoring Device and High Voltage Facility 1 Figures 1 and 2 to Part 1204 Commercial Practices CONSUMER... CITIZENS BAND BASE STATION ANTENNAS Pt. 1204, Figs. 1, 2 Figures 1 and 2 to Part 1204—Suggested Instrumentation for Current Monitoring Device and High Voltage Facility EC03OC91.008 ...

  9. Review of emergency obstetric care interventions in health facilities in the Upper East Region of Ghana: a questionnaire survey.

    PubMed

    Kyei-Onanjiri, Minerva; Carolan-Olah, Mary; Awoonor-Williams, John Koku; McCann, Terence V

    2018-03-15

    Maternal morbidity and mortality is most prevalent in resource-poor settings such as sub-Saharan Africa and southern Asia. In sub-Saharan Africa, Ghana is one of the countries still facing particular challenges in reducing its maternal morbidity and mortality. Access to emergency obstetric care (EmOC) interventions has been identified as a means of improving maternal health outcomes. Assessing the range of interventions provided in health facilities is, therefore, important in determining capacity to treat obstetric emergencies. The aim of this study was to examine the availability of emergency obstetric care interventions in the Upper East Region of Ghana. A cross-sectional survey of 120 health facilities was undertaken. Status of emergency obstetric care was assessed through an interviewer administered questionnaire to directors/in-charge officers of maternity care units in selected facilities. Data were analysed using descriptive statistics. Eighty per cent of health facilities did not meet the criteria for provision of emergency obstetric care. Comparatively, private health facilities generally provided EmOC interventions less frequently than public health facilities. Other challenges identified include inadequate skill mix of maternity health personnel, poor referral processes, a lack of reliable communication systems and poor emergency transport systems. Multiple factors combine to limit women's access to a range of essential maternal health services. The availability of EmOC interventions was found to be low across the region; however, EmOC facilities could be increased by nearly one-third through modest investments in some existing facilities. Also, the key challenges identified in this study can be improved by enhancing pre-existing health system structures such as Community-based Health Planning and Services (CHPS), training more midwifery personnel, strengthening in-service training and implementation of referral audits as part of health service

  10. Monitoring the implementation of the WHO Global Code of Practice on the International Recruitment of Health Personnel

    PubMed Central

    Zurn, Pascal; Rø, Otto Christian; Gedik, Gulin; Ronquillo, Kenneth; Joan Co, Christine; Vaillancourt-Laflamme, Catherine; dela Rosa, Jennifer; Perfilieva, Galina; Dal Poz, Mario Roberto

    2013-01-01

    Abstract Objective To present the findings of the first round of monitoring of the global implementation of the WHO Global Code of Practice on the International Recruitment of Health Personnel (“the Code”), a voluntary code adopted in 2010 by all 193 Member States of the World Health Organization (WHO). Methods WHO requested that its Member States designate a national authority for facilitating information exchange on health personnel migration and the implementation of the Code. Each designated authority was then sent a cross-sectional survey with 15 questions on a range of topics pertaining to the 10 articles included in the Code. Findings A national authority was designated by 85 countries. Only 56 countries reported on the status of Code implementation. Of these, 37 had taken steps towards implementing the Code, primarily by engaging relevant stakeholders. In 90% of countries, migrant health professionals reportedly enjoy the same legal rights and responsibilities as domestically trained health personnel. In the context of the Code, cooperation in the area of health workforce development goes beyond migration-related issues. An international comparative information base on health workforce mobility is needed but can only be developed through a collaborative, multi-partnered approach. Conclusion Reporting on the implementation of the Code has been suboptimal in all but one WHO region. Greater collaboration among state and non-state actors is needed to raise awareness of the Code and reinforce its relevance as a potent framework for policy dialogue on ways to address the health workforce crisis. PMID:24347705

  11. SD46 Facilities and Capabilities

    NASA Technical Reports Server (NTRS)

    Ramachandran, N.; Curreri, Peter A. (Technical Monitor)

    2002-01-01

    The displays for the Materials Conference presents some of the facilities and capabilities in SD46 that can be useful to a prospective researcher from University, Academia or other government labs. Several of these already have associated personnel as principal and co-investigators on NASA peer reviewed science investigations. 1. SCN purification facility 2. ESL facility 3. Static and Dynamic magnetic field facility 4. Microanalysis facility 5. MSG Investigation - PFMI 6. Thermo physical Properties Measurement Capabilities.

  12. Risk Management Technique for design and operation of facilities and equipment

    NASA Technical Reports Server (NTRS)

    Fedor, O. H.; Parsons, W. N.; Coutinho, J. De S.

    1975-01-01

    The Risk Management System collects information from engineering, operating, and management personnel to identify potentially hazardous conditions. This information is used in risk analysis, problem resolution, and contingency planning. The resulting hazard accountability system enables management to monitor all identified hazards. Data from this system are examined in project reviews so that management can decide to eliminate or accept these risks. This technique is particularly effective in improving the management of risks in large, complex, high-energy facilities. These improvements are needed for increased cooperation among industry, regulatory agencies, and the public.

  13. Assessment of laboratory logistics management information system practice for HIV/AIDS and tuberculosis laboratory commodities in selected public health facilities in Addis Ababa, Ethiopia.

    PubMed

    Desale, Adino; Taye, Bineyam; Belay, Getachew; Nigatu, Alemayehu

    2013-01-01

    Logistics management information system for health commodities remained poorly implemented in most of developing countries. To assess the status of laboratory logistics management information system for HIV/AIDS and tuberculosis laboratory commodities in public health facilities in Addis Ababa. A cross-sectional descriptive study was conducted from September 2010-January 2011 at selected public health facilities. A stratified random sampling method was used to include a total of 43 facilities which, were investigated through quantitative methods using structured questionnaires interviews. Focus group discussion with the designated supply chain managers and key informant interviews were conducted for the qualitative method. There exists a well-designed logistics system for laboratory commodities with trained pharmacy personnel, distributed standard LMIS formats and established inventory control procedures. However, majority of laboratory professionals were not trained in LMIS. Majority of the facilities (60.5%) were stocked out for at least one ART monitoring and TB laboratory reagents and the highest stock out rate was for chemistry reagents. Expired ART monitoring laboratory commodities were found in 25 (73.5%) of facilities. Fifty percent (50%) of the assessed hospitals and 54% of health centers were currently using stock/bin cards for all HIV/AIDS and TB laboratory commodities in main pharmacy store, among these only 25% and 20.8% of them were updated with accurate information matching with the physical count done at the time of visit for hospitals and health centers respectively. Even though there exists a well designed laboratory LMIS, keeping quality stock/bin cards and LMIS reports were very low. Key ART monitoring laboratory commodities were stock out at many facilities at the day of visit and during the past six months. Based on findings, training of laboratory personnel's managing laboratory commodities and keeping accurate inventory control procedures

  14. Assessment of laboratory logistics management information system practice for HIV/AIDS and tuberculosis laboratory commodities in selected public health facilities in Addis Ababa, Ethiopia

    PubMed Central

    Desale, Adino; Taye, Bineyam; Belay, Getachew; Nigatu, Alemayehu

    2013-01-01

    Introduction Logistics management information system for health commodities remained poorly implemented in most of developing countries. To assess the status of laboratory logistics management information system for HIV/AIDS and tuberculosis laboratory commodities in public health facilities in Addis Ababa. Methods A cross-sectional descriptive study was conducted from September 2010-January 2011 at selected public health facilities. A stratified random sampling method was used to include a total of 43 facilities which, were investigated through quantitative methods using structured questionnaires interviews. Focus group discussion with the designated supply chain managers and key informant interviews were conducted for the qualitative method. Results There exists a well-designed logistics system for laboratory commodities with trained pharmacy personnel, distributed standard LMIS formats and established inventory control procedures. However, majority of laboratory professionals were not trained in LMIS. Majority of the facilities (60.5%) were stocked out for at least one ART monitoring and TB laboratory reagents and the highest stock out rate was for chemistry reagents. Expired ART monitoring laboratory commodities were found in 25 (73.5%) of facilities. Fifty percent (50%) of the assessed hospitals and 54% of health centers were currently using stock/bin cards for all HIV/AIDS and TB laboratory commodities in main pharmacy store, among these only 25% and 20.8% of them were updated with accurate information matching with the physical count done at the time of visit for hospitals and health centers respectively. Conclusion Even though there exists a well designed laboratory LMIS, keeping quality stock/bin cards and LMIS reports were very low. Key ART monitoring laboratory commodities were stock out at many facilities at the day of visit and during the past six months. Based on findings, training of laboratory personnel's managing laboratory commodities and keeping

  15. Monitored retrievable storage submission to Congress: Volume 2, Environmental assessment for a monitored retrievable storage facility. [Contains glossary

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    1986-02-01

    This Environmental Assessment (EA) supports the DOE proposal to Congress to construct and operate a facility for monitored retrievable storage (MRS) of spent fuel at a site on the Clinch River in the Roane County portion of Oak Ridge, Tennessee. The first part of this document is an assessment of the value of, need for, and feasibility of an MRS facility as an integral component of the waste management system. The second part is an assessment and comparison of the potential environmental impacts projected for each of six site-design combinations. The MRS facility would be centrally located with respect tomore » existing reactors, and would receive and canister spent fuel in preparation for shipment to and disposal in a geologic repository. 207 refs., 57 figs., 132 tabs.« less

  16. 32 CFR 728.1 - Mission of Navy Medical Department facilities.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... PERSONNEL MEDICAL AND DENTAL CARE FOR ELIGIBLE PERSONS AT NAVY MEDICAL DEPARTMENT FACILITIES General § 728.1... is to provide medical and dental care for members of the Navy and Marine Corps and for members of the... facilities may provide medical and dental care to dependents of military personnel, to members not on active...

  17. 32 CFR 728.1 - Mission of Navy Medical Department facilities.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... PERSONNEL MEDICAL AND DENTAL CARE FOR ELIGIBLE PERSONS AT NAVY MEDICAL DEPARTMENT FACILITIES General § 728.1... is to provide medical and dental care for members of the Navy and Marine Corps and for members of the... facilities may provide medical and dental care to dependents of military personnel, to members not on active...

  18. 32 CFR 728.1 - Mission of Navy Medical Department facilities.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... PERSONNEL MEDICAL AND DENTAL CARE FOR ELIGIBLE PERSONS AT NAVY MEDICAL DEPARTMENT FACILITIES General § 728.1... is to provide medical and dental care for members of the Navy and Marine Corps and for members of the... facilities may provide medical and dental care to dependents of military personnel, to members not on active...

  19. 32 CFR 728.1 - Mission of Navy Medical Department facilities.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... PERSONNEL MEDICAL AND DENTAL CARE FOR ELIGIBLE PERSONS AT NAVY MEDICAL DEPARTMENT FACILITIES General § 728.1... is to provide medical and dental care for members of the Navy and Marine Corps and for members of the... facilities may provide medical and dental care to dependents of military personnel, to members not on active...

  20. Grande Ronde Endemic Spring Chinook Salmon Supplementation Program: Facility Operation and Maintenance and Monitoring and Evaluation, 2001 Annual Report.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boe, Stephen J.; Ogburn, Parker N.

    2003-03-01

    This is the second annual report of a multi-year project to operate adult collection and juvenile acclimation facilities on Catherine Creek and the upper Grande Ronde River for Snake River spring chinook salmon. These two streams have historically supported populations that provided significant tribal and non-tribal fisheries. Supplementation using conventional and captive broodstock techniques is being used to restore fisheries in these streams. Statement of Work Objectives for 2001: (1) Participate in implementation of the comprehensive multiyear operations plan for the Grande Ronde Endemic Spring chinook Supplementation Program (GRESCP). (2) Plan detailed GRESCP Monitoring and Evaluation for future years. (3)more » Ensure proper construction and trial operation of semi-permanent adult and juvenile facilities for use in 2001. (4) Plan for data collection needs for bull trout. (5) Ensure proper construction and trial operation of semi-permanent adult and juvenile facilities for use in 2001. (6) Collect summer steelhead. (7) Monitor adult endemic spring chinook salmon populations and collect broodstock. (8) Acclimate juvenile spring chinook salmon prior to release into the upper Grande Ronde River and Catherine Creek. (9) Monitor adult population abundance and characteristics of Grande Ronde River spring chinook salmon populations. (10) Monitor condition, movement, and mortality of spring chinook salmon acclimated at remote facilities. (11) Participate in Monitoring & Evaluation of the captive brood component of the Program to document contribution to the Program. (12) Monitor water quality at facilities. (13) Document accomplishments and needs to permitters, comanagers, and funding agencies. (14) Communicate Project results to the scientific community.« less

  1. Improved Real-Time Monitoring Using Multiple Expert Systems

    NASA Technical Reports Server (NTRS)

    Schwuttke, Ursula M.; Angelino, Robert; Quan, Alan G.; Veregge, John; Childs, Cynthia

    1993-01-01

    Monitor/Analyzer of Real-Time Voyager Engineering Link (MARVEL) computer program implements combination of techniques of both conventional automation and artificial intelligence to improve monitoring of complicated engineering system. Designed to support ground-based operations of Voyager spacecraft, also adapted to other systems. Enables more-accurate monitoring and analysis of telemetry, enhances productivity of monitoring personnel, reduces required number of such personnel by performing routine monitoring tasks, and helps ensure consistency in face of turnover of personnel. Programmed in C language and includes commercial expert-system software shell also written in C.

  2. The International Remote Monitoring Project: Results of the Swedish Nuclear Power Facility field trial

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, C.S.; af Ekenstam, G.; Sallstrom, M.

    1995-07-01

    The Swedish Nuclear Power Inspectorate (SKI) and the US Department of Energy (DOE) sponsored work on a Remote Monitoring System (RMS) that was installed in August 1994 at the Barseback Works north of Malmo, Sweden. The RMS was designed to test the front end detection concept that would be used for unattended remote monitoring activities. Front end detection reduces the number of video images recorded and provides additional sensor verification of facility operations. The function of any safeguards Containment and Surveillance (C/S) system is to collect information which primarily is images that verify the operations at a nuclear facility. Barsebackmore » is ideal to test the concept of front end detection since most activities of safeguards interest is movement of spent fuel which occurs once a year. The RMS at Barseback uses a network of nodes to collect data from microwave motion detectors placed to detect the entrance and exit of spent fuel casks through a hatch. A video system using digital compression collects digital images and stores them on a hard drive and a digital optical disk. Data and images from the storage area are remotely monitored via telephone from Stockholm, Sweden and Albuquerque, NM, USA. These remote monitoring stations operated by SKI and SNL respectively, can retrieve data and images from the RMS computer at the Barseback Facility. The data and images are encrypted before transmission. This paper presents details of the RMS and test results of this approach to front end detection of safeguard activities.« less

  3. 44 CFR 312.6 - Materials and facilities.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 44 Emergency Management and Assistance 1 2011-10-01 2011-10-01 false Materials and facilities. 312... OF HOMELAND SECURITY PREPAREDNESS USE OF CIVIL DEFENSE PERSONNEL, MATERIALS, AND FACILITIES FOR NATURAL DISASTER PURPOSES § 312.6 Materials and facilities. FEMA also contributes to the development and...

  4. Operational considerations in monitoring oxygen levels at the National Transonic Facility

    NASA Technical Reports Server (NTRS)

    Zalenski, M. A.; Rowe, E. L.; Mcphee, J. R.

    1985-01-01

    Laboratory monitoring of the level of oxygen in sample gas mixtures is a process which can be performed with accurate and repeatable results. Operations at the National Transonic Facility require the storage and pumping of large volumes of liquid nitrogen. To protect against the possibility of a fault resulting in a localized oxygen deficient atmosphere, the facility is equipped with a monitoring system with an array of sensors. During the early operational stages, the system produced recurrent alarms, none of which could be traced to a true oxygen deficiency. A thorough analysis of the system was undertaken with primary emphasis placed on the sensor units. These units sense the partial pressure of oxygen which, after signal conditioning, is presented as a % by volume indication at the system output. It was determined that many of the problems experienced were due to a lack of proper accounting for the partial pressure/% by volume relationship, with a secondary cause being premature sensor failure. Procedures were established to consider atmospherically induced partial pressure variations. Sensor rebuilding techniques were examined, and those elements contributing to premature sensor failure were identified. The system now operates with a high degree of confidence and reliability.

  5. Small Active Radiation Monitor

    NASA Technical Reports Server (NTRS)

    Badhwar, Gautam D.

    2004-01-01

    A device, named small active radiation monitor, allows on-orbit evaluations during periods of increased radiation, after extravehicular activities, or at predesignated times for crews on such long-duration space missions as on the International Space Station. It also permits direct evaluation of biological doses, a task now performed using a combination of measurements and potentially inaccurate simulations. Indeed the new monitor can measure a full array of radiation levels, from soft x-rays to hard galactic cosmic-ray particles. With refinement, it will benefit commercial (nuclear power-plant workers, airline pilots, medical technicians, physicians/dentists, and others) and military personnel as well as the astronauts for whom thermoluminescent dosimeters are inadequate. Civilian and military personnel have long since graduated from film badges to thermoluminescent dosimeters. Once used, most dosimeters must be returned to a central facility for processing, a step that can take days or even weeks. While this suffices for radiation workers for whom exposure levels are typically very low and of brief duration, it does not work for astronauts. Even in emergencies and using express mail, the results can often be delayed by as much as 24 hours. Electronic dosimeters, which are the size of electronic oral thermometers, and tattlers, small electronic dosimeters that sound an alarm when the dose/dose rate exceeds preset values, are also used but suffer disadvantages similar to those of thermoluminescent dosimeters. None of these devices fully answers the need of rapid monitoring during the space missions. Instead, radiation is monitored by passive detectors, which are read out after the missions. Unfortunately, these detectors measure only the absorbed dose and not the biologically relevant dose equivalent. The new monitor provides a real-time readout, a time history of radiation exposures (both absorbed dose and biologically relevant dose equivalent), and a count of the

  6. Development and Validation of Pathogen Environmental Monitoring Programs for Small Cheese Processing Facilities.

    PubMed

    Beno, Sarah M; Stasiewicz, Matthew J; Andrus, Alexis D; Ralyea, Robert D; Kent, David J; Martin, Nicole H; Wiedmann, Martin; Boor, Kathryn J

    2016-12-01

    Pathogen environmental monitoring programs (EMPs) are essential for food processing facilities of all sizes that produce ready-to-eat food products exposed to the processing environment. We developed, implemented, and evaluated EMPs targeting Listeria spp. and Salmonella in nine small cheese processing facilities, including seven farmstead facilities. Individual EMPs with monthly sample collection protocols were designed specifically for each facility. Salmonella was detected in only one facility, with likely introduction from the adjacent farm indicated by pulsed-field gel electrophoresis data. Listeria spp. were isolated from all nine facilities during routine sampling. The overall Listeria spp. (other than Listeria monocytogenes ) and L. monocytogenes prevalences in the 4,430 environmental samples collected were 6.03 and 1.35%, respectively. Molecular characterization and subtyping data suggested persistence of a given Listeria spp. strain in seven facilities and persistence of L. monocytogenes in four facilities. To assess routine sampling plans, validation sampling for Listeria spp. was performed in seven facilities after at least 6 months of routine sampling. This validation sampling was performed by independent individuals and included collection of 50 to 150 samples per facility, based on statistical sample size calculations. Two of the facilities had a significantly higher frequency of detection of Listeria spp. during the validation sampling than during routine sampling, whereas two other facilities had significantly lower frequencies of detection. This study provides a model for a science- and statistics-based approach to developing and validating pathogen EMPs.

  7. 40 CFR 160.31 - Testing facility management.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Testing facility management. 160.31... GOOD LABORATORY PRACTICE STANDARDS Organization and Personnel § 160.31 Testing facility management. For each study, testing facility management shall: (a) Designate a study director as described in § 160.33...

  8. Real-time monitoring of emissions from monoethanolamine-based industrial scale carbon capture facilities.

    PubMed

    Zhu, Liang; Schade, Gunnar Wolfgang; Nielsen, Claus Jørgen

    2013-12-17

    We demonstrate the capabilities and properties of using Proton Transfer Reaction time-of-flight mass spectrometry (PTR-ToF-MS) to real-time monitor gaseous emissions from industrial scale amine-based carbon capture processes. The benchmark monoethanolamine (MEA) was used as an example of amines needing to be monitored from carbon capture facilities, and to describe how the measurements may be influenced by potentially interfering species in CO2 absorber stack discharges. On the basis of known or expected emission compositions, we investigated the PTR-ToF-MS MEA response as a function of sample flow humidity, ammonia, and CO2 abundances, and show that all can exhibit interferences, thus making accurate amine measurements difficult. This warrants a proper sample pretreatment, and we show an example using a dilution with bottled zero air of 1:20 to 1:10 to monitor stack gas concentrations at the CO2 Technology Center Mongstad (TCM), Norway. Observed emissions included many expected chemical species, dominantly ammonia and acetaldehyde, but also two new species previously not reported but emitted in significant quantities. With respect to concerns regarding amine emissions, we show that accurate amine quantifications in the presence of water vapor, ammonia, and CO2 become feasible after proper sample dilution, thus making PTR-ToF-MS a viable technique to monitor future carbon capture facility emissions, without conventional laborious sample pretreatment.

  9. Process auditing in long term care facilities.

    PubMed

    Hewitt, S M; LeSage, J; Roberts, K L; Ellor, J R

    1985-01-01

    The ECC tool development and audit experiences indicated that there is promise in developing a process audit tool to monitor quality of care in nursing homes; moreover, the tool selected required only one hour per resident. Focusing on the care process and resident needs provided useful information for care providers at the unit level as well as for administrative personnel. Besides incorporating a more interdisciplinary focus, the revised tool needs to define support services most appropriate for nursing homes, includes items related to discharge planning and increases measurement of significant others' involvement in the care process. Future emphasis at the ECC will focus on developing intervention plans to maintain strengths and correct deficiencies identified in the audits. Various strategies to bring about desired changes in the quality of care will be evaluated through regular, periodic monitoring. Having a valid and reliable measure of quality of care as a tool will be an important step forward for LTC facilities.

  10. The importance of public sector health facility-level data for monitoring changes in maternal mortality risks among communities: the case of pakistan.

    PubMed

    Jain, Anrudh K; Sathar, Zeba; Salim, Momina; Shah, Zakir Hussain

    2013-09-01

    This paper illustrates the importance of monitoring health facility-level information to monitor changes in maternal mortality risks. The annual facility-level maternal mortality ratios (MMRs), complications to live births ratios and case fatality ratios (CFRs) were computed from data recorded during 2007 and 2009 in 31 upgraded public sector health facilities across Pakistan. The facility-level MMR declined by about 18%; both the number of Caesarean sections and the episodes of complications as a percentage of live births increased; and CFR based on Caesarean sections and episodes of complications declined by 29% and 37%, respectively. The observed increases in the proportion of women with complications among those who come to these facilities point to a reduction in the delay in reaching facilities (first and second delays; Thaddeus & Maine, 1994); the decrease in CFRs points to improvements in treating obstetric complications and a reduction in the delay in receiving treatment once at facilities (the third delay). These findings point to a decline in maternal mortality risks among communities served by these facilities. A system of woman-level data collection instituted at health facilities with comprehensive emergency obstetric care is essential to monitor changes in the effects of any reduction in the three delays and any improvement in quality of care or the effectiveness of treating pregnancy-related complications among women reaching these facilities. Such a system of information gathering at these health facilities would also help policymakers and programme mangers to measure and improve the effectiveness of safe-motherhood initiatives and to monitor progress being made toward achieving the fifth Millennium Development Goal.

  11. The automatic control system and stand-by facilities of the TDMA-40 equipment

    NASA Astrophysics Data System (ADS)

    Gudenko, D. V.; Pankov, G. Kh.; Pauk, A. G.; Tsirlin, V. M.

    1980-10-01

    When a controlling station in a satellite communications system is out of order, a complex algorithm must be carried out for automatic operation of the stand-by equipment. A processor has been developed to perform this algorithm, as well as operations involving the stand-by facilities of the receiving-transmitting equipment of the station. The design principles and solutions to problems in developing the equipment for the monitoring and controlling systems are described. These systems are based on multistation access using time division multiplexing. Algorithms are presented for the operation of the synchronizing processor and the control processor of the equipment. The automatic control system and stand-by facilities make it possible to reduce the service personnel and to design an unattended station.

  12. Unattended wireless proximity sensor networks for counterterrorism, force protection, littoral environments, PHM, and tamper monitoring ground applications

    NASA Astrophysics Data System (ADS)

    Forcier, Bob

    2003-09-01

    This paper describes a digital-ultrasonic ground network, which forms an unique "unattended mote sensor system" for monitoring the environment, personnel, facilities, vehicles, power generation systems or aircraft in Counter-Terrorism, Force Protection, Prognostic Health Monitoring (PHM) and other ground applications. Unattended wireless smart sensor/tags continuously monitor the environment and provide alerts upon changes or disruptions to the environment. These wireless smart sensor/tags are networked utilizing ultrasonic wireless motes, hybrid RF/Ultrasonic Network Nodes and Base Stations. The network is monitored continuously with a 24/7 remote and secure monitoring system. This system utilizes physical objects such as a vehicle"s structure or a building to provide the media for two way secure communication of key metrics and sensor data and eliminates the "blind spots" that are common in RF solutions because of structural elements of buildings, etc. The digital-ultrasonic sensors have networking capability and a 32-bit identifier, which provide a platform for a robust data acquisition (DAQ) for a large amount of sensors. In addition, the network applies a unique "signature" of the environment by comparing sensor-to-sensor data to pick up on minute changes, which would signal an invasion of unknown elements or signal a potential tampering in equipment or facilities. The system accommodates satellite and other secure network uplinks in either RF or UWB protocols. The wireless sensors can be dispersed by ground or air maneuvers. In addition, the sensors can be incorporated into the structure or surfaces of vehicles, buildings, or clothing of field personnel.

  13. 76 FR 63356 - Proposed Information Collection (Locality Pay System for Nurses and Other Health Care Personnel...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-12

    ... (Locality Pay System for Nurses and Other Health Care Personnel) Activity; Comment Request AGENCY: Veterans... to determine locality pay rates for nurses at VA facilities. DATES: Written comments and... forms of information technology. Title: Locality Pay System for Nurses and Other Health Care Personnel...

  14. Web-Based Real-Time Emergency Monitoring

    NASA Technical Reports Server (NTRS)

    Harvey, Craig A.; Lawhead, Joel

    2007-01-01

    The Web-based Real-Time Asset Monitoring (RAM) module for emergency operations and facility management enables emergency personnel in federal agencies and local and state governments to monitor and analyze data in the event of a natural disaster or other crisis that threatens a large number of people and property. The software can manage many disparate sources of data within a facility, city, or county. It was developed on industry-standard Geo- Spatial software and is compliant with open GIS standards. RAM View can function as a standalone system, or as an integrated plugin module to Emergency Operations Center (EOC) software suites such as REACT (Real-time Emergency Action Coordination Tool), thus ensuring the widest possible distribution among potential users. RAM has the ability to monitor various data sources, including streaming data. Many disparate systems are included in the initial suite of supported hardware systems, such as mobile GPS units, ambient measurements of temperature, moisture and chemical agents, flow meters, air quality, asset location, and meteorological conditions. RAM View displays real-time data streams such as gauge heights from the U.S. Geological Survey gauging stations, flood crests from the National Weather Service, and meteorological data from numerous sources. Data points are clearly visible on the map interface, and attributes as specified in the user requirements can be viewed and queried.

  15. Federal Radiological Monitoring and Assessment Center Monitoring Manual Volume 1, Operations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NSTec Aerial Measurement Systems

    2012-07-31

    The Monitoring division is primarily responsible for the coordination and direction of: Aerial measurements to delineate the footprint of radioactive contaminants that have been released into the environment. Monitoring of radiation levels in the environment; Sampling to determine the extent of contaminant deposition in soil, water, air and on vegetation; Preliminary field analyses to quantify soil concentrations or depositions; and Environmental and personal dosimetry for FRMAC field personnel, during a Consequence Management Response Team (CMRT) and Federal Radiological Monitoring and Assessment Center (FRMAC) response. Monitoring and sampling techniques used during CM/FRMAC operations are specifically selected for use during radiological emergenciesmore » where large numbers of measurements and samples must be acquired, analyzed, and interpreted in the shortest amount of time possible. In addition, techniques and procedures are flexible so that they can be used during a variety of different scenarios; e.g., accidents involving releases from nuclear reactors, contamination by nuclear waste, nuclear weapon accidents, space vehicle reentries, or contamination from a radiological dispersal device. The Monitoring division also provides technicians to support specific Health and Safety Division activities including: The operation of the Hotline; FRMAC facility surveys; Assistance with Health and Safety at Check Points; and Assistance at population assembly areas which require support from the FRMAC. This volume covers deployment activities, initial FRMAC activities, development and implementation of the monitoring and assessment plan, the briefing of field teams, and the transfer of FRMAC to the EPA.« less

  16. 48 CFR 1337.110-70 - Personnel security processing requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Personnel security processing requirements. 1337.110-70 Section 1337.110-70 Federal Acquisition Regulations System DEPARTMENT OF... where foreign national access to any DOC facility or DOC IT system is required. The language of the...

  17. 48 CFR 1337.110-70 - Personnel security processing requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 48 Federal Acquisition Regulations System 5 2012-10-01 2012-10-01 false Personnel security processing requirements. 1337.110-70 Section 1337.110-70 Federal Acquisition Regulations System DEPARTMENT OF... where foreign national access to any DOC facility or DOC IT system is required. The language of the...

  18. 48 CFR 1337.110-70 - Personnel security processing requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 48 Federal Acquisition Regulations System 5 2014-10-01 2014-10-01 false Personnel security processing requirements. 1337.110-70 Section 1337.110-70 Federal Acquisition Regulations System DEPARTMENT OF... where foreign national access to any DOC facility or DOC IT system is required. The language of the...

  19. Support systems of the orbiting quarantine facility

    NASA Technical Reports Server (NTRS)

    1981-01-01

    The physical support systems, the personnel management structure, and the contingency systems necessary to permit the Orbiting Quarantine Facility (OQF) to function as an integrated system are described. The interactions between the subsystems within the preassembled modules are illustrated. The Power Module generates and distributes electrical power throughout each of the four modules, stabilizes the OQF's attitude, and dissipates heat generated throughout the system. The Habitation Module is a multifunctional structure designed to monitor and control all aspects of the system's activities. The Logistics Module stores the supplies needed for 30 days of operation and provides storage for waste materials generated during the mission. The Laboratory Module contains the equipment necessary for executing the protocol, as well as an independent life support system.

  20. Nutrition knowledge of active-duty Navy personnel.

    PubMed

    Trent, L K

    1992-06-01

    As evidence continues to mount implicating diet in the etiology of disease, the US Navy is developing nutrition education programs designed to reflect the consolidated dietary recommendations of national expert agencies. The purpose of this study was to provide a baseline assessment of the level of nutrition knowledge among Navy personnel. Forty true/false questions were developed to test nutrition knowledge as conveyed by the Navy's instructional manual for nutrition educators. The questionnaire was mailed to a representative sample of all active-duty Navy personnel. Usable questionnaires were received from 2,938 participants (72.7% response rate). Mean number of correct items was 26.1 (65%). Nutrition knowledge was higher among older respondents, more highly educated personnel, whites, officers, women, and overweight individuals. Knowledge was weakest in the areas of calories/food intake and carbohydrates and strongest on vitamins/minerals and fiber. Program managers were recommended to intensify efforts to reach low-scoring subgroups, place more emphasis on the role of complex carbohydrates, disseminate guidelines for using nutrition labels on products, and develop point-of-choice nutrition education interventions for military dining facilities.

  1. Maximum reasonable radioxenon releases from medical isotope production facilities and their effect on monitoring nuclear explosions.

    PubMed

    Bowyer, Theodore W; Kephart, Rosara; Eslinger, Paul W; Friese, Judah I; Miley, Harry S; Saey, Paul R J

    2013-01-01

    Fission gases such as (133)Xe are used extensively for monitoring the world for signs of nuclear testing in systems such as the International Monitoring System (IMS). These gases are also produced by nuclear reactors and by fission production of (99)Mo for medical use. Recently, medical isotope production facilities have been identified as the major contributor to the background of radioactive xenon isotopes (radioxenon) in the atmosphere (Stocki et al., 2005; Saey, 2009). These releases pose a potential future problem for monitoring nuclear explosions if not addressed. As a starting point, a maximum acceptable daily xenon emission rate was calculated, that is both scientifically defendable as not adversely affecting the IMS, but also consistent with what is possible to achieve in an operational environment. This study concludes that an emission of 5 × 10(9) Bq/day from a medical isotope production facility would be both an acceptable upper limit from the perspective of minimal impact to monitoring stations, but also appears to be an achievable limit for large isotope producers. Copyright © 2012 Elsevier Ltd. All rights reserved.

  2. 21 CFR 58.31 - Testing facility management.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL GOOD LABORATORY PRACTICE FOR NONCLINICAL LABORATORY STUDIES Organization and Personnel § 58.31 Testing facility management. For each nonclinical laboratory study, testing facility management shall: (a) Designate a study...

  3. Guidelines to Career Development for Wastewater Treatment Plant Personnel.

    ERIC Educational Resources Information Center

    Environmental Protection Agency, Washington, DC. Office of Education and Manpower Planning.

    The guidelines were written to promote job growth and improvement in the personnel who manage, operate, and maintain wastewater treatment plants. Trained operators and technicians are the key components in any water pollution control facility. The approach is to move from employment to training through specific modules for 21 standard job…

  4. MIMI: multimodality, multiresource, information integration environment for biomedical core facilities.

    PubMed

    Szymanski, Jacek; Wilson, David L; Zhang, Guo-Qiang

    2009-10-01

    The rapid expansion of biomedical research has brought substantial scientific and administrative data management challenges to modern core facilities. Scientifically, a core facility must be able to manage experimental workflow and the corresponding set of large and complex scientific data. It must also disseminate experimental data to relevant researchers in a secure and expedient manner that facilitates collaboration and provides support for data interpretation and analysis. Administratively, a core facility must be able to manage the scheduling of its equipment and to maintain a flexible and effective billing system to track material, resource, and personnel costs and charge for services to sustain its operation. It must also have the ability to regularly monitor the usage and performance of its equipment and to provide summary statistics on resources spent on different categories of research. To address these informatics challenges, we introduce a comprehensive system called MIMI (multimodality, multiresource, information integration environment) that integrates the administrative and scientific support of a core facility into a single web-based environment. We report the design, development, and deployment experience of a baseline MIMI system at an imaging core facility and discuss the general applicability of such a system in other types of core facilities. These initial results suggest that MIMI will be a unique, cost-effective approach to addressing the informatics infrastructure needs of core facilities and similar research laboratories.

  5. 21 CFR 606.40 - Facilities.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ...) Provide adequate space for the following when applicable: (1) Private and accurate examinations of... convenient toilet facilities for donors and personnel. Drains shall be of adequate size and, where connected...

  6. 21 CFR 606.40 - Facilities.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ...) Provide adequate space for the following when applicable: (1) Private and accurate examinations of... convenient toilet facilities for donors and personnel. Drains shall be of adequate size and, where connected...

  7. 21 CFR 606.40 - Facilities.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ...) Provide adequate space for the following when applicable: (1) Private and accurate examinations of... convenient toilet facilities for donors and personnel. Drains shall be of adequate size and, where connected...

  8. Los Alamos Plutonium Facility Waste Management System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, K.; Montoya, A.; Wieneke, R.

    1997-02-01

    This paper describes the new computer-based transuranic (TRU) Waste Management System (WMS) being implemented at the Plutonium Facility at Los Alamos National Laboratory (LANL). The Waste Management System is a distributed computer processing system stored in a Sybase database and accessed by a graphical user interface (GUI) written in Omnis7. It resides on the local area network at the Plutonium Facility and is accessible by authorized TRU waste originators, count room personnel, radiation protection technicians (RPTs), quality assurance personnel, and waste management personnel for data input and verification. Future goals include bringing outside groups like the LANL Waste Management Facilitymore » on-line to participate in this streamlined system. The WMS is changing the TRU paper trail into a computer trail, saving time and eliminating errors and inconsistencies in the process.« less

  9. Strategies to Mitigate a Mycobacterium marinum Outbreak in a Zebrafish Research Facility

    PubMed Central

    Snell, Kathy; Mittge, Erika; Melancon, Ellie; Montgomery, Rebecca; McFadden, Marcie; Camoriano, Javier; Kent, Michael L.; Whipps, Christopher M.; Peirce, Judy

    2016-01-01

    Abstract In 2011, the zebrafish research facility at the University of Oregon experienced an outbreak of Mycobacterium marinum that affected both research fish and facility staff. A thorough review of risks to personnel, the zebrafish veterinary care program, and zebrafish husbandry procedures at the research facility followed. In the years since 2011, changes have been implemented throughout the research facility to protect the personnel, the fish colony, and ultimately the continued success of the zebrafish model research program. In this study, we present the history of the outbreak, the changes we implemented, and recommendations to mitigate pathogen outbreaks in zebrafish research facilities. PMID:27351618

  10. 5 CFR 430.207 - Monitoring performance.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 5 Administrative Personnel 1 2014-01-01 2014-01-01 false Monitoring performance. 430.207 Section 430.207 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS PERFORMANCE MANAGEMENT Performance Appraisal for General Schedule, Prevailing Rate, and Certain Other Employees § 430.207...

  11. 5 CFR 430.207 - Monitoring performance.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 5 Administrative Personnel 1 2012-01-01 2012-01-01 false Monitoring performance. 430.207 Section 430.207 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS PERFORMANCE MANAGEMENT Performance Appraisal for General Schedule, Prevailing Rate, and Certain Other Employees § 430.207...

  12. 5 CFR 430.207 - Monitoring performance.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Monitoring performance. 430.207 Section 430.207 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS PERFORMANCE MANAGEMENT Performance Appraisal for General Schedule, Prevailing Rate, and Certain Other Employees § 430.207...

  13. Naval Facilities Engineering Command Needs to Improve Controls Over Task Order Administration

    DTIC Science & Technology

    2015-07-02

    consolidated joint use Submarine Learning Center and Submarine Squadron Headquarters facility that: • includes training space for submarine crews, and...allows frequent and timely interaction between Headquarters personnel, Submarine Learning Center instructors, and waterfront operations personnel...Introduction DODIG-2015-141 │ 3 Project P-528 provides a Torpedo Exercise Support facility that: • supports submarine crew training and certification to

  14. Grande Ronde Endemic Spring Chinook Salmon Supplementation Program: Facility Operation and Maintenance and Monitoring and Evaluation, 2000 Annual Report.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boe, Stephen J.; Lofy, Peter T.

    2003-03-01

    This is the third annual report of a multi-year project to operate adult collection and juvenile acclimation facilities on Catherine Creek and the upper Grande Ronde River for Snake River spring chinook salmon. These two streams have historically supported populations that provided significant tribal and non-tribal fisheries. Supplementation using conventional and captive broodstock techniques is being used to restore fisheries in these streams. Statement of Work Objectives for 2000: (1) Participate in implementation of the comprehensive multiyear operations plan for the Grande Ronde Endemic Spring Chinook Supplementation Program (GRESCP). (2) Plan for recovery of endemic summer steelhead populations in Catherinemore » Creek and the upper Grande Ronde River. (3) Ensure proper construction and trial operation of semi-permanent adult and juvenile facilities for use in 2000. (4) Collect summer steelhead. (5) Collect adult endemic spring chinook salmon broodstock. (6) Acclimate juvenile spring chinook salmon prior to release into the upper Grande Ronde River and Catherine Creek. (7) Document accomplishments and needs to permitters, comanagers, and funding agency. (8) Communicate project results to the scientific community. (9) Plan detailed GRESCP Monitoring and Evaluation for future years. (10) Monitor adult population abundance and characteristics of Grande Ronde River spring chinook salmon populations and incidentally-caught summer steelhead and bull trout. (11) Monitor condition, movement, and mortality of spring chinook salmon acclimated at remote facilities. (12) Monitor water quality at facilities. (13) Participate in Monitoring & Evaluation of the captive brood component of the Program to document contribution to the Program.« less

  15. A hydrologic retention system and water quality monitoring program for a human decomposition research facility: concept and design.

    PubMed

    Wozniak, Jeffrey R; Thies, Monte L; Bytheway, Joan A; Lutterschmidt, William I

    2015-01-01

    Forensic taphonomy is an essential research field; however, the decomposition of human cadavers at forensic science facilities may lead to nutrient loading and the introduction of unique biological compounds to adjacent areas. The infrastructure of a water retention system may provide a mechanism for the biogeochemical processing and retention of nutrients and compounds, ensuring the control of runoff from forensic facilities. This work provides a proof of concept for a hydrologic retention system and an autonomous water quality monitoring program designed to mitigate runoff from The Southeast Texas Applied Forensic Science (STAFS) Facility. Water samples collected along a sample transect were analyzed for total phosphorous, total nitrogen, NO3-, NO2-, NH4, F(-), and Cl(-). Preliminary water quality analyses confirm the overall effectiveness of the water retention system. These results are discussed with relation to how this infrastructure can be expanded upon to monitor additional, more novel, byproducts of forensic science research facilities. © 2014 American Academy of Forensic Sciences.

  16. Regulatory facility guide for Ohio

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anderson, S.S.; Bock, R.E.; Francis, M.W.

    1994-02-28

    The Regulatory Facility Guide (RFG) has been developed for the DOE and contractor facilities located in the state of Ohio. It provides detailed compilations of international, federal, and state transportation-related regulations applicable to shipments originating at destined to Ohio facilities. This RFG was developed as an additional resource tool for use both by traffic managers who must ensure that transportation operations are in full compliance with all applicable regulatory requirements and by oversight personnel who must verify compliance activities.

  17. A systematic review of the effects of euthanasia and occupational stress in personnel working with animals in animal shelters, veterinary clinics, and biomedical research facilities.

    PubMed

    Scotney, Rebekah L; McLaughlin, Deirdre; Keates, Helen L

    2015-11-15

    The study of occupational stress and compassion fatigue in personnel working in animal-related occupations has gained momentum over the last decade. However, there remains incongruence in understanding what is currently termed compassion fatigue and the associated unique contributory factors. Furthermore, there is minimal established evidence of the likely influence of these conditions on the health and well-being of individuals working in various animal-related occupations. To assess currently available evidence and terminology regarding occupational stress and compassion fatigue in personnel working in animal shelters, veterinary clinics, and biomedical research facilities. Studies were identified by searching the following electronic databases with no publication date restrictions: ProQuest Research Library, ProQuest Social Science Journals, PsycARTICLES, Web of Science, Science Direct, Scopus, PsychINFO databases, and Google Scholar. Search terms included (euthanasia AND animals) OR (compassion fatigue AND animals) OR (occupational stress AND animals). Only articles published in English in peer-reviewed journals that included use of quantitative or qualitative techniques to investigate the incidence of occupational stress or compassion fatigue in the veterinary profession or animal-related occupations were included. On the basis of predefined criteria, 1 author extracted articles, and the data set was then independently reviewed by the other 2 authors. 12 articles met the selection criteria and included a variety of study designs and methods of data analysis. Seven studies evaluated animal shelter personnel, with the remainder evaluating veterinary nurses and technicians (2), biomedical research technicians (1), and personnel in multiple animal-related occupations (2). There was a lack of consistent terminology and agreed definitions for the articles reviewed. Personnel directly engaged in euthanasia reported significantly higher levels of work stress and lower

  18. 40 CFR 160.51 - Specimen and data storage facilities.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 25 2012-07-01 2012-07-01 false Specimen and data storage facilities... PROGRAMS GOOD LABORATORY PRACTICE STANDARDS Facilities § 160.51 Specimen and data storage facilities. Space shall be provided for archives, limited to access by authorized personnel only, for the storage and...

  19. 40 CFR 160.51 - Specimen and data storage facilities.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 24 2011-07-01 2011-07-01 false Specimen and data storage facilities... PROGRAMS GOOD LABORATORY PRACTICE STANDARDS Facilities § 160.51 Specimen and data storage facilities. Space shall be provided for archives, limited to access by authorized personnel only, for the storage and...

  20. 40 CFR 160.51 - Specimen and data storage facilities.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 25 2013-07-01 2013-07-01 false Specimen and data storage facilities... PROGRAMS GOOD LABORATORY PRACTICE STANDARDS Facilities § 160.51 Specimen and data storage facilities. Space shall be provided for archives, limited to access by authorized personnel only, for the storage and...

  1. 40 CFR 160.51 - Specimen and data storage facilities.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 24 2014-07-01 2014-07-01 false Specimen and data storage facilities... PROGRAMS GOOD LABORATORY PRACTICE STANDARDS Facilities § 160.51 Specimen and data storage facilities. Space shall be provided for archives, limited to access by authorized personnel only, for the storage and...

  2. Assessment of management policies and practices for occupational exposure to bloodborne pathogens in dialysis facilities.

    PubMed

    Mbaeyi, Chukwuma; Panlilio, Adelisa L; Hobbs, Cynthia; Patel, Priti R; Kuhar, David T

    2012-10-01

    Occupational exposure management is an important element in preventing the transmission of bloodborne pathogens in health care settings. In 2008, the US Centers for Disease Control and Prevention conducted a survey to assess procedures for managing occupational bloodborne pathogen exposures in outpatient dialysis facilities in the United States. A cross-sectional survey of randomly selected outpatient dialysis facilities. 339 outpatient dialysis facilities drawn from the 2006 US end-stage renal disease database. Hospital affiliation (free-standing vs hospital-based facilities), profit status (for-profit vs not-for-profit facilities), and number of health care personnel (≥100 vs <100 health care personnel). Exposures to hepatitis B virus (HBV), hepatitis C virus (HCV), and human immunodeficiency virus (HIV); provision of HBV and HIV postexposure prophylaxis. We calculated the proportion of facilities reporting occupational bloodborne pathogen exposures and offering occupational exposure management services. We analyzed bloodborne pathogen exposures and provision of postexposure prophylaxis by facility type. Nearly all respondents (99.7%) had written policies and 95% provided occupational exposure management services to health care personnel during the daytime on weekdays, but services were provided infrequently during other periods of the week. Approximately 10%-15% of facilities reported having HIV, HBV, or HCV exposures in health care personnel in the 12 months prior to the survey, but inconsistencies were noted in procedures for managing such exposures. Despite 86% of facilities providing HIV prophylaxis for exposed health care personnel, only 37% designated a primary HIV postexposure prophylaxis regimen. For-profit and free-standing facilities reported fewer exposures, but did not as reliably offer HBV prophylaxis or have a primary HIV postexposure prophylaxis regimen relative to not-for-profit and hospital-based facilities. The survey response rate was low

  3. LAFD: TA-55 General Facility Familiarization Tour, Course #55261

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rutherford, Victor Stephen; Miller, Joshua; Mason, Robert Clifford

    Los Alamos National Laboratory (LANL) will conduct familiarization tours for personnel of the Los Alamos County Fire Department (LAFD) at the TA-55 General Facility. These familiarization tours are official LANL business; the purpose of these tours is to orient LAFD firefighters to the facility so that they can respond efficiently and quickly to a variety of emergency situations. This orientation includes, among other topics, ingress and egress of the area and buildings, layout and organization of the facility, evacuation procedures and assembly points, and areas of concern within the various buildings at the facility. LAFD firefighters have the skills andmore » abilities to perform firefighting operations and other emergency response tasks that cannot be provided by LANL personnel who have the required clearance level. This handout provides details of the information, along with maps and diagrams, to be presented during the familiarization tours. The handout will be distributed to the trainees at the time of the tour. A corresponding checklist will also be used as guidance during the familiarization tours to ensure that all required information is presented to LAFD personnel.« less

  4. The Experimental Lakes Area: Over 45 Years of Whole Ecosystem Monitoring and Manipulation Experiments and a Focus on the Future

    NASA Astrophysics Data System (ADS)

    Emmerton, C. A.

    2015-12-01

    The IISD Experimental Lakes Area is a unique facility which has existed since 1968 and consists of 58 lakes and their watersheds set aside for research purposes. The IISD-ELA also boasts an on-site water chemistry lab, accommodations and facilities for up to 60 personnel. Since its inception in 1968 over 50 whole ecosystem experiments have been conducted at the ELA including eutrophication, acidification of lakes, environmental mercury fates, hydro-electric reservoir impacts and much more. The recent partnership between IISD and ELA has allowed ELA to refocus on freshwater research and policy development in a time where the preservation of the earth's most precious resource is of the utmost concern. In addition to water quality monitoring, the ELA is also focused on autotrophic ecology, zooplankton community structures, fish population and behaviour and food-web interactions. Monitoring all of these disciplines and their inter-relationships gives the research facility a unique perspective and along with the long term dataset stretching back to 1968 the ELA can look at historical records to monitor long term changes in the environment.

  5. Supporting NASA Facilities Through GIS

    NASA Technical Reports Server (NTRS)

    Ingham, Mary E.

    2000-01-01

    The NASA GIS Team supports NASA facilities and partners in the analysis of spatial data. Geographic Information System (G[S) is an integration of computer hardware, software, and personnel linking topographic, demographic, utility, facility, image, and other geo-referenced data. The system provides a graphic interface to relational databases and supports decision making processes such as planning, design, maintenance and repair, and emergency response.

  6. 14 CFR 145.103 - Housing and facilities requirements.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ....103 Section 145.103 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF..., Materials, and Data § 145.103 Housing and facilities requirements. (a) Each certificated repair station must provide— (1) Housing for the facilities, equipment, materials, and personnel consistent with its ratings...

  7. 14 CFR 145.103 - Housing and facilities requirements.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ....103 Section 145.103 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF..., Materials, and Data § 145.103 Housing and facilities requirements. (a) Each certificated repair station must provide— (1) Housing for the facilities, equipment, materials, and personnel consistent with its ratings...

  8. 14 CFR 145.103 - Housing and facilities requirements.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ....103 Section 145.103 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF..., Materials, and Data § 145.103 Housing and facilities requirements. (a) Each certificated repair station must provide— (1) Housing for the facilities, equipment, materials, and personnel consistent with its ratings...

  9. 14 CFR 145.103 - Housing and facilities requirements.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ....103 Section 145.103 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF..., Materials, and Data § 145.103 Housing and facilities requirements. (a) Each certificated repair station must provide— (1) Housing for the facilities, equipment, materials, and personnel consistent with its ratings...

  10. Microbiological monitoring of guinea pigs reared conventionally at two breeding facilities in Korea.

    PubMed

    Park, Jong-Hwan; Seok, Seung-Hyeok; Baek, Min-Won; Lee, Hui-Young; Kim, Dong-Jae; Cho, Jung-Sik; Kim, Chuel-Kyu; Hwang, Dae-Youn; Park, Jae-Hak

    2006-10-01

    In this study, microbiological monitoring of guinea pigs reared conventionally in two facilities was performed twice in 2004, with a three-month-interval between surveys. This study was based on the recommendations of the FELASA Working Group, with some modifications. In serological tests in the first survey, some animals from facility A showed positive results for Encephalitozoon cuniculi, Sendai virus, pneumonia virus of mice (PVM), and Reovirus-3 (Reo-3); facility B showed a positive result only for E. cuniculi. The results of the second survey were similar to the first, except for the presence of Sendai virus; all animals from the two facilities were Sendai virus-negative in the second experiment. No pathogenic bacteria were cultured in the organs of any of the animals in the first survey. However, in the second survey, Bordetella bronchiseptica was cultured from the lung tissue of two 10-week-old animals from facility A. Chlamydial infection was examined by the Macchiavello method, but no animal showed positive results. Tests using fecal flotation or the KOH wet mount method showed no infection of endoparasites, protozoa, ectoparasites, or dermatophytes in any animal in both surveys. However, in the histopathological examination, an infection of protozoa-like organisms was observed in the cecum of some animals from facility A. The present study revealed that microbiological contamination was present in guinea pigs reared conventionally in two facilities in Korea, suggesting that there is a need to improve environmental conditions in order to eradicate microbial contamination.

  11. Navy-wide Personnel Survey (NPS) 2000: Statistical Tables of Survey Results for Officers and Enlisted Sailors

    DTIC Science & Technology

    2003-09-01

    Navy Personnel Research, Studies, and Technology Department Navy Personnel Command (NPRST/PERS-1) Millington, TN, 38055-1000 NPRST-TN-03-10... Technology 5720 Integrity Drive Millington, Tennessee 38055-1400 NPRST-TN-03-10 9. SPONSORING / MONITORING AGENCY NAME(S) AND ADDRESS(ES... Technology Department Navy Personnel Command 5720 Integrity Drive Millington, TN 38055-1400 www.nprst.navy.mil v Foreword Administered biennially

  12. Initial utilization of the CVIRB video production facility

    NASA Technical Reports Server (NTRS)

    Parrish, Russell V.; Busquets, Anthony M.; Hogge, Thomas W.

    1987-01-01

    Video disk technology is one of the central themes of a technology demonstrator workstation being assembled as a man/machine interface for the Space Station Data Management Test Bed at Johnson Space Center. Langley Research Center personnel involved in the conception and implementation of this workstation have assembled a video production facility to allow production of video disk material for this propose. This paper documents the initial familiarization efforts in the field of video production for those personnel and that facility. Although the entire video disk production cycle was not operational for this initial effort, the production of a simulated disk on video tape did acquaint the personnel with the processes involved and with the operation of the hardware. Invaluable experience in storyboarding, script writing, audio and video recording, and audio and video editing was gained in the production process.

  13. Enabling appropriate personnel skill-mix for progressive realization of equitable access to assistive technology.

    PubMed

    Smith, Emma M; Gowran, Rosemary Joan; Mannan, Hasheem; Donnelly, Brian; Alvarez, Liliana; Bell, Diane; Contepomi, Silvana; Ennion Wegner, Liezel; Hoogerwerf, Evert-Jan; Howe, Tracey; Jan, Yih-Kuen; Kagwiza, Jeanne; Layton, Natasha; Ledgerd, Ritchard; MacLachlan, Malcolm; Oggero, Giulia; Pettersson, Cecilia; Pousada, Thais; Scheffler, Elsje; Wu, Sam

    2018-05-17

    This paper reviews the current capacity of personnel in enabling access to assistive technology (AT) as well as the systems and processes within which they work, and was reviewed, discussed, and refined during and following the Global Research, Innovation, and Education in Assistive Technology (GREAT) Summit. Key concepts addressed include a person-centred team approach; sustainability indicators to monitor, measure, and respond to needs for service design and delivery; education, research, and training for competent practice, using the six rehab-workforce challenges framework; and credentialing frameworks. We propose development of a competence framework and associated education and training programs, and development and implementation of a certification framework for AT personnel. There is a resolve to address the challenges faced by People globally to access assistive technology. Context specific needs assessment is required to understand the AT Personnel landscape, to shape and strengthen credentialing frameworks through competencies and certification, acknowledging both general and specific skill mix requirements. Implications for Rehabilitation Personnel in assistive technology (AT) provision should be trained using a person-centred team approach, which emphasizes appropriate skill-mix to address multiple needs within the community. Sustainability indicators should be used which allow personnel to monitor, measure and respond to needs for service design and delivery. A competence framework with associated education and training program, coupled with the development and implementation of a certification framework for AT personnel needs, will promote quality in AT personnel training globally.

  14. 5 CFR 1636.150 - Program accessibility: Existing facilities.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... facilities. 1636.150 Section 1636.150 Administrative Personnel FEDERAL RETIREMENT THRIFT INVESTMENT BOARD... RETIREMENT THRIFT INVESTMENT BOARD § 1636.150 Program accessibility: Existing facilities. (a) General. The... fundamental alteration in the nature of a program or activity or in undue financial and administrative burdens...

  15. Health Care Personnel Perception of the Privacy of Electronic Health Records.

    PubMed

    Saito, Kenji; Shofer, Frances S; Saberi, Poune; Green-McKenzie, Judith

    2017-06-01

    : Health care facilities are increasingly converting paper medical records to electronic health records. This study investigates the perception of privacy health care personnel have of electronic health records. A pilot tested, anonymous survey was administered to a convenience sample of health care personnel. Standard summary statistics and Chi-square analysis were used to assess differences in perception. Of the 93% (96/103) who responded, 65% were female and 43% white. The mean age was 44.3 years. Most (94%) felt that Medical Record privacy was important and one-third reported they would not seek care at their workplace if Electronic Health Records were used. Efforts to assure and communicate the integrity of electronic health records are essential toward reducing deterrents for health care personnel to access geographically convenient and timely health care.

  16. Exploring the Use of Activity Patterns for Smart Monitoring of Nuclear Facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, Karen Ann

    The world is at an inflection point where our ability to collect data now far outpaces our ability to make use of it. LANL has a number of efforts to help us pull more meaningful insights out of our data and target resources to where they will be most impactful. We are exploring an approach to recognizing activity patterns across disparate data streams for a more holistic view of nuclear facility monitoring.

  17. A facility monitoring system: The single most valuable and cost-effective tool available to an energy manager

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Holmes, W.A.

    Energy engineering and management combines engineering problem-solving and financial management techniques to reduce utility costs. At present, substantial amounts of time and money are being spent in order to attempt to quantify energy consumption and costs and define opportunities for savings. Unfortunately, accurate verification of results is often overlooked. Advances in technology during the last few years have made the installation of a permanent, PC-based monitoring system possible for any facility, often for no more than the cost of a detailed study. By investing initially in a monitoring system rather than audits or studies, the actual consumption and cost datamore » will be available on a continuing basis and can be used to produce immediate operational savings, more accurately analyze opportunities requiring capital investments, and to verify actual savings resulting from changes. A permanent monitoring system, installed as the first step in a utility cost reduction effort, to identify where and how energy is used in a facility on a dynamic and real-time basis, can provide the most valuable and cost-effective tool available to an energy manager. The resulting data allows energy consumption patterns and utility costs to be understood and managed in the same manner as all other costs within a facility.« less

  18. Coordination between airway facilities specialists and air traffic personnel.

    DOT National Transportation Integrated Search

    2002-04-01

    Airway Facilities (AF) is responsible for providing services and conducting operations that deliver the highest possible levels of National Airspace System (NAS) safety and efficiency. To accomplish this, AF specialists perform maintenance tasks for ...

  19. Engineering Personnel Data Needs for the 1990s.

    ERIC Educational Resources Information Center

    National Academy of Sciences - National Research Council, Washington, DC. Office of Scientific and Engineering Personnel.

    This report summarizes the deliberations of the Office of Scientific and Engineering Personnel's Committee on Data Needs for Monitoring Labor-Market Conditions for Engineers. The purpose of this report is to help the profession make existing data bases on engineers more complete, accurate, and compatible. The report is also intended to help…

  20. Monitoring the performances of a real scale municipal solid waste composting and a biodrying facility using respiration activity indices.

    PubMed

    Evangelou, Alexandros; Gerassimidou, Spyridoula; Mavrakis, Nikitas; Komilis, Dimitrios

    2016-05-01

    Objective of the work was to monitor two full-scale commingled municipal solid waste (MSW) mechanical and biological pretreatment (MBT) facilities in Greece, namely a biodrying and a composting facility. Monitoring data from a 1.5-year sampling period is presented, whilst microbial respiration indices were used to monitor the decomposition process and the stability status of the wastes in both facilities during the process. Results showed that in the composting facility, the organic matter reduced by 35 % after 8 weeks of combined composting/curing. Material exiting the biocells had a moisture content of less than 30 % (wb) indicating a moisture limitation during the active composting process. The static respiration indexes indicated that some stabilization occurred during the process, but the final material could not be characterized as stable compost. In the biodrying facility, the initial and final moisture contents were 50 % and less than 20 % wb, respectively, and the biodrying index was equal to 4.1 indicating effective biodrying. Lower heating values at the inlet and outlet were approximately 5.5 and 10 MJ/wet kg, respectively. The organic matter was reduced by 20 % during the process and specifically from a range of 63-77 % dw (inlet) to a range of 61-70 % dw. A significant respiration activity reduction was observed for some of the biodrying samples. A statistically significant correlation among all three respiration activity indices was recorded, with the two oxygen related activity indices (CRI7 and SRI24) observing the highest correlation.

  1. 48 CFR 42.402 - Visits to contractors' facilities.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Visits to contractors... contractors' facilities. (a) Government personnel planning to visit a contractor's facility in connection with... positions, and security clearances. (2) Date and duration of visit. (3) Name and address of contractor and...

  2. MANUAL OF STANDARDS FOR REHABILITATION CENTERS AND FACILITIES.

    ERIC Educational Resources Information Center

    CANIFF, CHARLES E.; AND OTHERS

    A 5-YEAR PROJECT TO SPECIFY STANDARDS OF REHABILITATION CENTERS AND FACILITIES RESULTED IN THREE PUBLICATIONS. THIS MANUAL INCLUDES THE CHARACTERISTICS AND GOALS OF REHABILITATION FACILITIES. THE STANDARDS FOR ORGANIZATION, SERVICES THAT SHOULD BE PROVIDED, PERSONNEL INCLUDED, RECORDS AND REPORTS, FISCAL MANAGEMENT, AND THE PHYSICAL PLANT ARE…

  3. 5 CFR 1207.150 - Program accessibility: Existing facilities.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... facilities. 1207.150 Section 1207.150 Administrative Personnel MERIT SYSTEMS PROTECTION BOARD ORGANIZATION... CONDUCTED BY THE MERIT SYSTEMS PROTECTION BOARD § 1207.150 Program accessibility: Existing facilities. (a) General. The agency shall operate each program or activity so that the program or activity, when viewed in...

  4. FALLOUT DOSAGE AND MONITORING

    PubMed Central

    Kinsman, Simon

    1960-01-01

    At present there are a large number of people capable of conducting the task of surface and area radiation monitoring including external monitoring of personnel. Once the extent and the intensity of radioactivity in an area is determined, good use of personnel can be made without too much risk. This is fortunate for the medical profession whose personnel can devote their talents to casualty care during or following nuclear warfare. Most individuals who know how to detect and measure the extent of radioactive contamination are also capable of conducting personnel decontamination operations and would do so if necessary. Consequently the spread of contamination can be minimized by adequate decontamination and the medical personnel can treat casualties who are relatively free of external radioactive contamination. The appropriate use of trained manpower and radiation detection equipment which are available in California combined with sufficient rehearsals prior to a nuclear war will greatly reduce any casualty damage due to radioactive fallout. The chances of survival of individuals can be greatly improved with a little knowledge of protection from radioactive contamination and of salvage of food and water. PMID:14409247

  5. 11. Historic view of Building 100 control room, showing personnel ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    11. Historic view of Building 100 control room, showing personnel operating rocket engine test controls and observer watching activity from observation room. May 27, 1957. On file at NASA Plumbrook Research Center, Sandusky, Ohio. NASA photo number C-45020. - Rocket Engine Testing Facility, GRC Building No. 100, NASA Glenn Research Center, Cleveland, Cuyahoga County, OH

  6. Gemini base facility operations environmental monitoring: key systems and tools for the remote operator

    NASA Astrophysics Data System (ADS)

    Cordova, Martin; Serio, Andrew; Meza, Francisco; Arriagada, Gustavo; Swett, Hector; Ball, Jesse; Collins, Paul; Masuda, Neal; Fuentes, Javier

    2016-07-01

    In 2014 Gemini Observatory started the base facility operations (BFO) project. The project's goal was to provide the ability to operate the two Gemini telescopes from their base facilities (respectively Hilo, HI at Gemini North, and La Serena, Chile at Gemini South). BFO was identified as a key project for Gemini's transition program, as it created an opportunity to reduce operational costs. In November 2015, the Gemini North telescope started operating from the base facility in Hilo, Hawaii. In order to provide the remote operator the tools to work from the base, many of the activities that were normally performed by the night staff at the summit were replaced with new systems and tools. This paper describes some of the key systems and tools implemented for environmental monitoring, and the design used in the implementation at the Gemini North telescope.

  7. A Review of Avian Monitoring and Mitigation Information at Existing Utility-Scale Solar Facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Walston, Leroy J.; Rollins, Katherine E.; Smith, Karen P.

    2015-01-01

    There are two basic types of solar energy technology: photovoltaic and concentrating solar power. As the number of utility-scale solar energy facilities using these technologies is expected to increase in the United States, so are the potential impacts on wildlife and their habitats. Recent attention is on the risk of fatality to birds. Understanding the current rates of avian mortality and existing monitoring requirements is an important first step in developing science-based mitigation and minimization protocols. The resulting information also allows a comparison of the avian mortality rates of utility-scale solar energy facilities with those from other technologies and sources,more » as well as the identification of data gaps and research needs. This report will present and discuss the current state of knowledge regarding avian issues at utility-scale solar energy facilities.« less

  8. [RADIATION SAFETY DURING REMEDIATION OF THE "SEVRAO" FACILITIES].

    PubMed

    Shandala, N K; Kiselev, S M; Titov, A V; Simakov, A V; Seregin, V A; Kryuchkov, V P; Bogdanova, L S; Grachev, M I

    2015-01-01

    Within a framework of national program on elimination of nuclear legacy, State Corporation "Rosatom" is working on rehabilitation at the temporary waste storage facility at Andreeva Bay (Northwest Center for radioactive waste "SEVRAO"--the branch of "RosRAO"), located in the North-West of Russia. In the article there is presented an analysis of the current state of supervision for radiation safety of personnel and population in the context of readiness of the regulator to the implementation of an effective oversight of radiation safety in the process of radiation-hazardous work. Presented in the article results of radiation-hygienic monitoring are an informative indicator of the effectiveness of realized rehabilitation measures and characterize the radiation environment in the surveillance zone as a normal, without the tendency to its deterioration.

  9. Playing Hardball with Facilities Expenses.

    ERIC Educational Resources Information Center

    Fickes, Michael

    1997-01-01

    Describes one school district manager's tactics for successfully controlling district costs and increasing capital improvements while only marginally increasing the facilities maintenance budget. Highlights guidelines for controlling personnel requirements and cost-reduction methods. Discusses specific cost-control measures involving telephone…

  10. Gaps in monitoring systems for Implanon NXT services in South Africa: An assessment of 12 facilities in two districts

    PubMed

    Pillay, D; Morroni, C; Pleaner, M; Adeogba, O; Chersich, M; Naidoo, N; Mullick, S; Rees, H

    2017-10-01

    Background. Implanon NXT, a long-acting subdermal contraceptive implant, was introduced in South Africa (SA) in early 2014 as part of an expanded contraceptive method mix. After initial high levels of uptake, reports emerged of frequent early removals and declines in use. Monitoring of progress and challenges in implant service delivery could identify aspects of the programme that require strengthening. Objectives. To assess data management and record keeping within implant services at primary care facilities. Methods. We developed a checklist to assess the tools used for monitoring implant services and data reporting to district offices. The checklist was piloted in seven facilities. An additional six high-volume and six low-volume implant insertion clinics in the City of Johannesburg (CoJ), Gauteng Province, and the Dr Kenneth Kaunda District, North West Province, were selected for assessment. Results. All 12 facilities completed a Daily Head Count Register, which tallied the number of clients attending the clinic, but not information about implant use. A more detailed Tick Register recorded services that clinic attendees received, with nine documenting number of implant insertions and six implant removals. A more specific tool, an Insertion Checklist, collected data on insertion procedures and client characteristics, but was only used in CoJ (five of six facilities). Other registers, which were developed de novo by staff at individual facilities, captured more detailed information about insertions and removals, including reasons. Five of six low-volume insertion facilities used these registers, but only three of six high-volume facilities. No facilities used the form specifically developed by the National Department of Health for implant pharmacovigilance. Nine of 12 clinics reported data on numbers of insertions to the district office, six reported removals and none provided data on reasons for removals. Conclusion. For data to inform effective decision

  11. Development of a model protection and dynamic response monitoring system for the national transonic facility

    NASA Technical Reports Server (NTRS)

    Young, Clarence P., Jr.; Balakrishna, S.; Kilgore, W. Allen

    1995-01-01

    A state-of-the-art, computerized mode protection and dynamic response monitoring system has been developed for the NASA Langley Research Center National Transonic Facility (NTF). This report describes the development of the model protection and shutdown system (MPSS). A technical description of the system is given along with discussions on operation and capabilities of the system. Applications of the system to vibration problems are presented to demonstrate the system capabilities, typical applications, versatility, and investment research return derived from the system to date. The system was custom designed for the NTF but can be used at other facilities or for other dynamic measurement/diagnostic applications. Potential commercial uses of the system are described. System capability has been demonstrated for forced response testing and for characterizing and quantifying bias errors for onboard inertial model attitude measurement devices. The system is installed in the NTF control room and has been used successfully for monitoring, recording and analyzing the dynamic response of several model systems tested in the NTF.

  12. Monitoring techniques and alarm procedures for CMS services and sites in WLCG

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Molina-Perez, J.; Bonacorsi, D.; Gutsche, O.

    2012-01-01

    The CMS offline computing system is composed of roughly 80 sites (including most experienced T3s) and a number of central services to distribute, process and analyze data worldwide. A high level of stability and reliability is required from the underlying infrastructure and services, partially covered by local or automated monitoring and alarming systems such as Lemon and SLS, the former collects metrics from sensors installed on computing nodes and triggers alarms when values are out of range, the latter measures the quality of service and warns managers when service is affected. CMS has established computing shift procedures with personnel operatingmore » worldwide from remote Computing Centers, under the supervision of the Computing Run Coordinator at CERN. This dedicated 24/7 computing shift personnel is contributing to detect and react timely on any unexpected error and hence ensure that CMS workflows are carried out efficiently and in a sustained manner. Synergy among all the involved actors is exploited to ensure the 24/7 monitoring, alarming and troubleshooting of the CMS computing sites and services. We review the deployment of the monitoring and alarming procedures, and report on the experience gained throughout the first two years of LHC operation. We describe the efficiency of the communication tools employed, the coherent monitoring framework, the proactive alarming systems and the proficient troubleshooting procedures that helped the CMS Computing facilities and infrastructure to operate at high reliability levels.« less

  13. 9. Acircuit weather cover in foreground, personnel access hatch, transporter/erector ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    9. A-circuit weather cover in foreground, personnel access hatch, transporter/erector grounding points at right center - Ellsworth Air Force Base, Delta Flight, Launch Facility D-6, 4 miles north of Badlands National Park Headquarters, 4.5 miles east of Jackson County line on county road, Interior, Jackson County, SD

  14. 14 CFR 145.103 - Housing and facilities requirements.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... TRANSPORTATION (CONTINUED) SCHOOLS AND OTHER CERTIFICATED AGENCIES REPAIR STATIONS Housing, Facilities, Equipment... temperature, humidity, and other climatic conditions sufficient to ensure personnel perform maintenance...

  15. 76 FR 14590 - Defense Federal Acquisition Regulation Supplement; Safety of Facilities, Infrastructure, and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-17

    ... facilities, infrastructure, and equipment that are intended for use by military or civilian personnel of the..., maintenance, or operation of facilities, infrastructure, and equipment for use by DoD military or civilian... facilities. This includes contracts for facilities, infrastructure, and equipment configured for occupancy...

  16. BSL-3 laboratory practices in the United States: comparison of select agent and non-select agent facilities.

    PubMed

    Richards, Stephanie L; Pompei, Victoria C; Anderson, Alice

    2014-01-01

    New construction of biosafety level 3 (BSL-3) laboratories in the United States has increased in the past decade to facilitate research on potential bioterrorism agents. The Centers for Disease Control and Prevention inspect BSL-3 facilities and review commissioning documentation, but no single agency has oversight over all BSL-3 facilities. This article explores the extent to which standard operating procedures in US BSL-3 facilities vary between laboratories with select agent or non-select agent status. Comparisons are made for the following variables: personnel training, decontamination, personal protective equipment (PPE), medical surveillance, security access, laboratory structure and maintenance, funding, and pest management. Facilities working with select agents had more complex training programs and decontamination procedures than non-select agent facilities. Personnel working in select agent laboratories were likely to use powered air purifying respirators, while non-select agent laboratories primarily used N95 respirators. More rigorous medical surveillance was carried out in select agent workers (although not required by the select agent program) and a higher level of restrictive access to laboratories was found. Most select agent and non-select agent laboratories reported adequate structural integrity in facilities; however, differences were observed in personnel perception of funding for repairs. Pest management was carried out by select agent personnel more frequently than non-select agent personnel. Our findings support the need to promote high quality biosafety training and standard operating procedures in both select agent and non-select agent laboratories to improve occupational health and safety.

  17. Environmental monitoring programme in the cell therapy facility of a research centre: preliminary investigation.

    PubMed

    Ottria, G; Dallera, M; Aresu, O; Manniello, M A; Parodi, B; Spagnolo, A M; Cristina, M L

    2010-12-01

    Recent discoveries in cell therapy research present new opportunities for cellular products to be used to treat severe, and as yet incurable, diseases. It is therefore essential to implement a quality control programme in order to ensure that safe cells and tissues are provided. In a preliminary phase of the setting up of a the cellfactory, monitoring was carried out monthly over a 6-month period in one out of three cell therapy laboratories and filter rooms in order to evaluate the microbial contamination of air and surfaces and the presence of airborne particulates. The mean total bacterial and fungal loads measured in the air in the centre of the filter room were 20.7 +/1 28.9 colony-forming units (cfu)/m3 and 9.2 +/- 15.4 cfu/m3, respectively, and 5.2 +/- 4.1 cfu/m3 and 6.8 +/- 13.4 cfu/m3, respectively, in the laboratory. The mean fungal load values recorded on the surfaces sampled in the laboratory were in 6 out of 18 cases higher than the reference values (5 cfu/plate). As to the results of particulate monitoring, with regard to the 0.5 microm particles, about 83% of the samples revealed values below the limit of 350.000 particles per cubic metre. In this set-up phase, monitoring was able to pick out structural and organisational flaws acceptable in a laboratory compliant with Good Manufacturing Practices class C (Annex 1), but not in a class B facility. Thanks to this preliminary monitoring phase, and by correcting these flaws, the clean room facility could achieve compliance to class B.

  18. Military personnel recognition system using texture, colour, and SURF features

    NASA Astrophysics Data System (ADS)

    Irhebhude, Martins E.; Edirisinghe, Eran A.

    2014-06-01

    This paper presents an automatic, machine vision based, military personnel identification and classification system. Classification is done using a Support Vector Machine (SVM) on sets of Army, Air Force and Navy camouflage uniform personnel datasets. In the proposed system, the arm of service of personnel is recognised by the camouflage of a persons uniform, type of cap and the type of badge/logo. The detailed analysis done include; camouflage cap and plain cap differentiation using gray level co-occurrence matrix (GLCM) texture feature; classification on Army, Air Force and Navy camouflaged uniforms using GLCM texture and colour histogram bin features; plain cap badge classification into Army, Air Force and Navy using Speed Up Robust Feature (SURF). The proposed method recognised camouflage personnel arm of service on sets of data retrieved from google images and selected military websites. Correlation-based Feature Selection (CFS) was used to improve recognition and reduce dimensionality, thereby speeding the classification process. With this method success rates recorded during the analysis include 93.8% for camouflage appearance category, 100%, 90% and 100% rates of plain cap and camouflage cap categories for Army, Air Force and Navy categories, respectively. Accurate recognition was recorded using SURF for the plain cap badge category. Substantial analysis has been carried out and results prove that the proposed method can correctly classify military personnel into various arms of service. We show that the proposed method can be integrated into a face recognition system, which will recognise personnel in addition to determining the arm of service which the personnel belong. Such a system can be used to enhance the security of a military base or facility.

  19. Math Problems for Water Quality Control Personnel, Instructor's Manual. Second Edition.

    ERIC Educational Resources Information Center

    Delvecchio, Fred; Brutsch, Gloria

    This document is the instructor's manual for a course in mathematics for water quality control personnel. It is designed so a program may be designed for a specific facility. The problem structures are arranged alphabetically by treatment process. Charts, graphs and/or drawings representing familiar data forms contain the necessary information to…

  20. DEVELOPMENT, INSTALLATION AND OPERATION OF THE MPC&A OPERATIONS MONITORING (MOM) SYSTEM AT THE JOINT INSTITUTE FOR NUCLEAR RESEARCH (JINR) DUBNA, RUSSIA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kartashov,V.V.; Pratt,W.; Romanov, Y.A.

    The Material Protection, Control and Accounting (MPC&A) Operations Monitoring (MOM) systems handling at the International Intergovernmental Organization - Joint Institute for Nuclear Research (JINR) is described in this paper. Category I nuclear material (plutonium and uranium) is used in JINR research reactors, facilities and for scientific and research activities. A monitoring system (MOM) was installed at JINR in April 2003. The system design was based on a vulnerability analysis, which took into account the specifics of the Institute. The design and installation of the MOM system was a collaborative effort between JINR, Brookhaven National Laboratory (BNL) and the U.S. Departmentmore » of Energy (DOE). Financial support was provided by DOE through BNL. The installed MOM system provides facility management with additional assurance that operations involving nuclear material (NM) are correctly followed by the facility personnel. The MOM system also provides additional confidence that the MPC&A systems continue to perform effectively.« less

  1. LAFD: TA-55 RLUOB/CUB Facility Familiarization Tour, OJT #55265

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rutherford, Victor Stephen

    2017-09-14

    Los Alamos National Laboratory (LANL) conducts familiarization tours for personnel of the Los Alamos County Fire Department (LAFD) at the RLUOB/CUB, technical area (TA)-55, 400/440, facility, Radiological Laboratory Utility Office Building (RLUOB)/Central Utility Building (CUB). These familiarization tours are official LANL business; the purpose of these tours is to orient LAFD firefighters to the facility so that they can respond efficiently and quickly to a variety of emergency situations. This orientation includes, among other topics, the ingress and egress of the area and buildings, layout and organization of the facility, evacuation procedures and assembly points, and areas of concern withinmore » the various buildings at the facility. LAFD firefighters have the skills and abilities to perform firefighting operations and other emergency response tasks that cannot be provided by other LANL personnel who have the required clearance level. This handout provides details of the information, along with maps and diagrams, to be presented during the familiarization tours. The handout is distributed to the trainees at the time of the tour; a corresponding checklist is also used as guidance during the familiarization tours to ensure that all required information is presented to LAFD personnel.« less

  2. Exposure monitoring of graphene nanoplatelets manufacturing workplaces.

    PubMed

    Lee, Ji Hyun; Han, Jong Hun; Kim, Jae Hyun; Kim, Boowook; Bello, Dhimiter; Kim, Jin Kwon; Lee, Gun Ho; Sohn, Eun Kyung; Lee, Kyungmin; Ahn, Kangho; Faustman, Elaine M; Yu, Il Je

    2016-01-01

    Graphenes have emerged as a highly promising, two-dimensional engineered nanomaterial that can possibly substitute carbon nanotubes. They are being explored in numerous R&D and industrial applications in laboratories across the globe, leading to possible human and environmental exposures to them. Yet, there are no published data on graphene exposures in occupational settings and no readily available methods for their detection and quantitation exist. This study investigates for the first time the potential exposure of workers and research personnel to graphenes in two research facilities and evaluates the status of the control measures. One facility manufactures graphene using graphite exfoliation and chemical vapor deposition (CVD), while the other facility grows graphene on a copper plate using CVD, which is then transferred to a polyethylene terephthalate (PET) sheet. Graphene exposures and process emissions were investigated for three tasks - CVD growth, exfoliation, and transfer - using a multi-metric approach, which utilizes several direct reading instruments, integrated sampling, and chemical and morphological analysis. Real-time instruments included a dust monitor, condensation particle counter (CPC), nanoparticle surface area monitor, scanning mobility particle sizer, and an aethalometer. Morphologically, graphenes and other nanostructures released from the work process were investigated using a transmission electron microscope (TEM). Graphenes were quantified in airborne respirable samples as elemental carbon via thermo-optical analysis. The mass concentrations of total suspended particulate at Workplaces A and B were very low, and elemental carbon concentrations were mostly below the detection limit, indicating very low exposure to graphene or any other particles. The real-time monitoring, especially the aethalometer, showed a good response to the released black carbon, providing a signature of the graphene released during the opening of the CVD reactor

  3. 5 CFR 2604.201 - Public reading room facility and Web site.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 5 Administrative Personnel 3 2011-01-01 2011-01-01 false Public reading room facility and Web site... DISCLOSURE REPORTS FOIA Public Reading Room Facility and Web Site; Index Identifying Information for the Public § 2604.201 Public reading room facility and Web site. (a)(1) Location of public reading room...

  4. 5 CFR 2604.201 - Public reading room facility and Web site.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 5 Administrative Personnel 3 2010-01-01 2010-01-01 false Public reading room facility and Web site... DISCLOSURE REPORTS FOIA Public Reading Room Facility and Web Site; Index Identifying Information for the Public § 2604.201 Public reading room facility and Web site. (a)(1) Location of public reading room...

  5. Sabbatical Report: Results of a Survey of Library Microforms Facilities.

    ERIC Educational Resources Information Center

    McIntosh, Melinda C.

    1987-01-01

    Highlights findings on the status of academic library microforms facilities in the United States and Canada based on visits to 11 libraries. Topics covered include administration, personnel, collection access and storage, classification, acquisition, circulation, indexes, hours, facilities, signage, equipment, photocopying, cleanliness, vandalism,…

  6. [Oral health hygiene education programme for nursing personnel to improve oral health of residents in long-term care facilities 2010 in Frankfurt/Main, Germany].

    PubMed

    Czarkowski, G; Allroggen, S; Köster-Schmidt, A; Bausback-Schomakers, S; Frank, M; Heudorf, U

    2013-06-01

    demonstrated, significant for plaque index, cleanliness of the tongue and denture hygiene index. The positive assessment of the nursing personnel as well as the positive effects on oral hygiene in the residents are in agreement with the results of many other studies in many countries. Therefore, these education programmes will be continued in the long-term care facilities in Frankfurt/Main, Germany.· © Georg Thieme Verlag KG Stuttgart · New York.

  7. BSL-3 Laboratory Practices in the United States: Comparison of Select Agent and Non–Select Agent Facilities

    PubMed Central

    Pompei, Victoria C.; Anderson, Alice

    2014-01-01

    New construction of biosafety level 3 (BSL-3) laboratories in the United States has increased in the past decade to facilitate research on potential bioterrorism agents. The Centers for Disease Control and Prevention inspect BSL-3 facilities and review commissioning documentation, but no single agency has oversight over all BSL-3 facilities. This article explores the extent to which standard operating procedures in US BSL-3 facilities vary between laboratories with select agent or non–select agent status. Comparisons are made for the following variables: personnel training, decontamination, personal protective equipment (PPE), medical surveillance, security access, laboratory structure and maintenance, funding, and pest management. Facilities working with select agents had more complex training programs and decontamination procedures than non–select agent facilities. Personnel working in select agent laboratories were likely to use powered air purifying respirators, while non–select agent laboratories primarily used N95 respirators. More rigorous medical surveillance was carried out in select agent workers (although not required by the select agent program) and a higher level of restrictive access to laboratories was found. Most select agent and non–select agent laboratories reported adequate structural integrity in facilities; however, differences were observed in personnel perception of funding for repairs. Pest management was carried out by select agent personnel more frequently than non–select agent personnel. Our findings support the need to promote high quality biosafety training and standard operating procedures in both select agent and non–select agent laboratories to improve occupational health and safety. PMID:24552359

  8. AUTOMATED RADIOLOGICAL MONITORING AT A RUSSIAN MINISTRY OF DEFENCE NAVAL SITE.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    MOSKOWITZ,P.D.; POMERVILLE,J.; GAVRILOV,S.

    2001-02-25

    The Arctic Military Environmental Cooperation (AMEC) Program is a cooperative effort between the military establishments of the Kingdom of Norway, the Russian Federation, and the US. This paper discusses joint activities conducted over the past year among Norwegian, Russian, and US technical experts on a project to develop, demonstrate and implement automated radiological monitoring at Russian Navy facilities engaged in the dismantlement of nuclear-powered strategic ballistic missile launching submarines. Radiological monitoring is needed at these facilities to help protect workers engaged in the dismantlement program and the public living within the footprint of routine and accidental radiation exposure areas. Bymore » providing remote stand-alone monitoring, the Russian Navy will achieve added protection due to the defense-in-depth strategy afforded by local (at the site), regional (Kola) and national-level (Moscow) oversight. The system being implemented at the Polyaminsky Russian Naval Shipyard was developed from a working model tested at the Russian Institute for Nuclear Safety, Moscow, Russia. It includes Russian manufactured terrestrial and underwater gamma detectors, smart controllers for graded sampling, radio-modems for offsite transmission of the data, and a data fusion/display system: The data fusion/display system is derived from the Norwegian Picasso AMEC Environmental Monitoring software package. This computer package allows monitoring personnel to review the real-time and historical status of monitoring at specific sites and objects and to establish new monitoring protocols as required, for example, in an off-normal accident situation. Plans are being developed to implement the use of this system at most RF Naval sites handling spent nuclear fuel.« less

  9. AUTOMATED RADIOLOGICAL MONITORING AT A RUSSIAN MINISTRY OF DEFENSE NAVAL SITE.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    MOSKOWITZ,P.D.; POMERVILLE,J.; GAVRILOV,S.

    2001-02-25

    The Arctic Military Environmental Cooperation (AMEC) Program is a cooperative effort between the military establishments of the Kingdom of Norway, the Russian Federation, and the US. This paper discusses joint activities conducted over the past year among Norwegian, Russian, and US technical experts on a project to develop, demonstrate and implement automated radiological monitoring at Russian Navy facilities engaged in the dismantlement of nuclear-powered strategic ballistic missile launching submarines. Radiological monitoring is needed at these facilities to help protect workers engaged in the dismantlement program and the public living within the footprint of routine and accidental radiation exposure areas. Bymore » providing remote stand-alone monitoring, the Russian Navy will achieve added protection due to the defense-in-depth strategy afforded by local (at the site), regional (Kola) and national-level (Moscow) oversight. The system being implemented at the Polyaminsky Russian Naval Shipyard was developed from a working model tested at the Russian Institute for Nuclear Safety, Moscow, Russia. It includes Russian manufactured terrestrial and underwater gamma detectors, smart controllers for graded sampling, radio-modems for offsite transmission of the data, and a data fusion/display system: The data fusion/display system is derived from the Norwegian Picasso AMEC Environmental Monitoring software package. This computer package allows monitoring personnel to review the real-time and historical status of monitoring at specific sites and objects and to establish new monitoring protocols as required, for example, in an off-normal accident situation. Plans are being developed to implement the use of this system at most RF Naval sites handling spent nuclear fuel.« less

  10. Augmented Fish Health Monitoring in Oregon, 1987-1988 Annual Report.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bauer, Jerry

    1988-05-01

    Diminished natural fish production in the Columbia River Basin has prompted increased artificial propagation to compensate both for losses of anadromous salmonids related to hydroelectric facilities and for other causes. The health and quality of artificially propagated smolts probably is a major influence on survival. Smolt survival varies greatly from one location to another, among different species and from one year to the next. Fish health monitoring is necessary to identify cause of mortality, assist in producing a healthy smolt, and provide a means for improving hatchery effectiveness. The Bonneville Power Administration (BPA) conducted a series of meetings to definemore » the minimum ''needed'' level of fish health monitoring, determine what was presently being done and what additional effort was needed in the Basin's 54 anadromous fish hatcheries. Funding for the additional effort in Oregon began June 2, 1987. The goal of this project is to increase smolt-to-adult survival by accomplishing the following: (1) increase monitoring for specific fish pathogens and fish health parameters; (2) measure hatchery water supply quality; (3) identify facility impediments to fish health; (4) create a database of hatchery and fish health information; (5) establish a technical steering committee to evaluate and refine the project annually; and (6) increase communication and technology application among personnel in hatcheries, research, management, other agencies and the public. 4 refs., 3 figs., 10 tabs.« less

  11. 2016 Annual Site Environmental report Sandia National Laboratories Tonopah Test Range Nevada & Kaua'i Test Facility Hawai'i.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Salas, Angela Maria; Griffith, Stacy R.

    Sandia National Laboratories (SNL) is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s (DOE’s), National Nuclear Security Administration (NNSA) under contract DE-NA0003525. The DOE/NNSA Sandia Field Office administers the contract and oversees contractor operations at the SNL, Tonopah Test Range (SNL/TTR) in Nevada and the SNL, Kaua‘i Test Facility (SNL/KTF) in Hawai‘i. SNL personnel manage and conduct operations at SNL/TTR in support of the DOE/NNSA’s Weapons Ordnance Program and have operated the site since 1957. Navarro Research and Engineeringmore » personnel perform most of the environmental programs activities at SNL/TTR. The DOE/NNSA/Nevada Field Office retains responsibility for cleanup and management of SNL/TTR Environmental Restoration sites. SNL personnel operate SNL/KTF as a rocket preparation launching and tracking facility. This Annual Site Environmental Report (ASER) summarizes data and the compliance status of sustainability, environmental protection, and monitoring programs at SNL/TTR and SNL/KTF during calendar year 2016. Major environmental programs include air quality, water quality, groundwater protection, terrestrial and biological surveillance, waste management, pollution prevention, environmental restoration, oil and chemical spill prevention, and implementation of the National Environmental Policy Act. This ASER is prepared in accordance with and as required by DOE O 231.1B, Admin Change 1, Environment, Safety, and Health Reporting.« less

  12. Infection control challenges in deployed US military treatment facilities.

    PubMed

    Hospenthal, Duane R; Crouch, Helen K

    2009-04-01

    Personnel sustaining combat-related injuries in current overseas conflicts continue to have their care complicated by infections caused by multidrug-resistant organisms, including Acinetobacter, Klebsiella, and Pseudomonas. Although presumed to be due to multiple factors both within and outside of the combat theater, concern has been raised about the difficulties in establishing and maintaining standard infection control (IC) practices in deployed medical treatment facilities and in the evacuation of the injured back to the United States. Level III facilities (hospitals capable of holding patients >72 hours) in Iraq and Afghanistan and the evacuation system from Iraq to the continental US were reviewed by an expert IC-infectious disease team. All reviewed facilities had established IC programs, but these were staffed by personnel with limited IC experience, often without perceived adequate time dedicated to perform their duties, and without uniform levels of command emphasis or support. Proper hand hygiene between patients was not always ideal. Isolation and cohorting of patients to decrease multidrug-resistant organism colonization and infection varied among facilities. Review of standard operating procedures found variability among institutions and in quality of these documents. Application of US national and theater-specific guidelines and of antimicrobial control measures also varied among facilities. Effective IC practices are often difficult to maintain in modern US hospitals. In the deployed setting, with ever-changing personnel in a less than optimal practice environment, IC is even more challenging. Standardization of practice with emphasis on the basics of IC practice (e.g., hand hygiene and isolation procedures) needs to be emplaced and maintained in the deployed setting.

  13. Personnel occupied woven envelope robot

    NASA Technical Reports Server (NTRS)

    Wessling, F. C.

    1986-01-01

    The use of nonmetallic or fabric structures for space application is considered. The following structures are suggested: (1) unpressurized space hangars; (2) extendable tunnels for soft docking; and (3) manned habitat for space stations, storage facilities, and work structures. The uses of the tunnel as a passageway: for personnel and equipment, eliminating extravehicular activity, for access to a control cabin on a space crane and between free flyers and the space station are outlined. The personnal occupied woven envelope robot (POWER) device is shown. The woven envelope (tunnel) acts as part of the boom of a crane. Potential applications of POWER are outlined. Several possible deflection mechanisms and design criteria are determined.

  14. Personnel Radiation Exposure Associated With X-Rays Emanating from U.S. Coast Guard LORAN High Voltage Vacuum Tube Transmitter Units

    DTIC Science & Technology

    2011-07-01

    dosimeter program. Unfortunately, this limited personnel monitoring program did not address the case of an individual who may have performed...and forearms; feet and ankles 18 ¾ Skin of whole body 7 ½ The USCG does maintain a small radiation personnel dosimeter monitoring program for x...ray technicians at USCG medical clinics (USCG, 2006). This medical clinic dosimeter program reflects a civilian standard of practice, where the x-ray

  15. EPA Facility Registry Service (FRS): CERCLIS

    EPA Pesticide Factsheets

    This data provides location and attribute information on Facilities regulated under the Comprehensive Environmental Responsibility Compensation and Liability Information System (CERCLIS) for a intranet web feature service . The data provided in this service are obtained from EPA's Facility Registry Service (FRS). The FRS is an integrated source of comprehensive (air, water, and waste) environmental information about facilities, sites or places. This service connects directly to the FRS database to provide this data as a feature service. FRS creates high-quality, accurate, and authoritative facility identification records through rigorous verification and management procedures that incorporate information from program national systems, state master facility records, data collected from EPA's Central Data Exchange registrations and data management personnel. Additional Information on FRS is available at the EPA website https://www.epa.gov/enviro/facility-registry-service-frs.

  16. Replacing Military Personnel in Support Positions With Civilian Employees

    DTIC Science & Technology

    2015-12-01

    resource services 0.3 0.5 0.1 Science and technology (S&T) and research and development (R&D) management and support...DoD’s Office of the Actuary . Civilian employees are not eligible for this benefit.  Health Care for Military Retirees Younger Than 65. Most service...that it is provided by military personnel at military facilities. However, DoD’s Office of the Actuary calculates a notional accrual amount that, if

  17. 5 CFR 2604.201 - Public reading room facility and Web site.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 5 Administrative Personnel 3 2012-01-01 2012-01-01 false Public reading room facility and Web site. 2604.201 Section 2604.201 Administrative Personnel OFFICE OF GOVERNMENT ETHICS ORGANIZATION AND PROCEDURES FREEDOM OF INFORMATION ACT RULES AND SCHEDULE OF FEES FOR THE PRODUCTION OF PUBLIC FINANCIAL DISCLOSURE REPORTS FOIA Public Reading Room...

  18. 5 CFR 2604.201 - Public reading room facility and Web site.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 5 Administrative Personnel 3 2014-01-01 2014-01-01 false Public reading room facility and Web site. 2604.201 Section 2604.201 Administrative Personnel OFFICE OF GOVERNMENT ETHICS ORGANIZATION AND PROCEDURES FREEDOM OF INFORMATION ACT RULES AND SCHEDULE OF FEES FOR THE PRODUCTION OF PUBLIC FINANCIAL DISCLOSURE REPORTS FOIA Public Reading Room...

  19. 5 CFR 2604.201 - Public reading room facility and Web site.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 5 Administrative Personnel 3 2013-01-01 2013-01-01 false Public reading room facility and Web site. 2604.201 Section 2604.201 Administrative Personnel OFFICE OF GOVERNMENT ETHICS ORGANIZATION AND PROCEDURES FREEDOM OF INFORMATION ACT RULES AND SCHEDULE OF FEES FOR THE PRODUCTION OF PUBLIC FINANCIAL DISCLOSURE REPORTS FOIA Public Reading Room...

  20. Validation of gamma-ray detection techniques for safeguards monitoring at natural uranium conversion facilities

    DOE PAGES

    Dewji, Shaheen A.; Lee, Denise L.; Croft, Stephen; ...

    2016-03-28

    Recent IAEA circulars and policy papers have sought to implement safeguards when any purified aqueous uranium solution or uranium oxides suitable for isotopic enrichment or fuel fabrication exists. Under the revised policy, IAEA Policy Paper 18, the starting point for nuclear material under safeguards was reinterpreted, suggesting that purified uranium compounds should be subject to safeguards procedures no later than the first point in the conversion process. In response to this technical need, a combination of simulation models and experimental measurements were employed to develop and validate concepts of nondestructive assay monitoring systems in a natural uranium conversion plant (NUCP).more » In particular, uranyl nitrate (UO 2(NO 3) 2) solution exiting solvent extraction was identified as a key measurement point (KMP), where gamma-ray spectroscopy was selected as the process monitoring tool. The Uranyl Nitrate Calibration Loop Equipment (UNCLE) facility at Oak Ridge National Laboratory was employed to simulate the full-scale operating conditions of a purified uranium-bearing aqueous stream exiting the solvent extraction process in an NUCP. Nondestructive assay techniques using gamma-ray spectroscopy were evaluated to determine their viability as a technical means for drawing safeguards conclusions at NUCPs, and if the IAEA detection requirements of 1 significant quantity (SQ) can be met in a timely way. This work investigated gamma-ray signatures of uranyl nitrate circulating in the UNCLE facility and evaluated various gamma-ray detector sensitivities to uranyl nitrate. These detector validation activities include assessing detector responses to the uranyl nitrate gamma-ray signatures for spectrometers based on sodium iodide, lanthanum bromide, and high-purity germanium detectors. The results of measurements under static and dynamic operating conditions at concentrations ranging from 10–90 g U/L of natural uranyl nitrate are presented. A range of gamma

  1. Validation of gamma-ray detection techniques for safeguards monitoring at natural uranium conversion facilities

    NASA Astrophysics Data System (ADS)

    Dewji, S. A.; Lee, D. L.; Croft, S.; Hertel, N. E.; Chapman, J. A.; McElroy, R. D.; Cleveland, S.

    2016-07-01

    Recent IAEA circulars and policy papers have sought to implement safeguards when any purified aqueous uranium solution or uranium oxides suitable for isotopic enrichment or fuel fabrication exists. Under the revised policy, IAEA Policy Paper 18, the starting point for nuclear material under safeguards was reinterpreted, suggesting that purified uranium compounds should be subject to safeguards procedures no later than the first point in the conversion process. In response to this technical need, a combination of simulation models and experimental measurements were employed to develop and validate concepts of nondestructive assay monitoring systems in a natural uranium conversion plant (NUCP). In particular, uranyl nitrate (UO2(NO3)2) solution exiting solvent extraction was identified as a key measurement point (KMP), where gamma-ray spectroscopy was selected as the process monitoring tool. The Uranyl Nitrate Calibration Loop Equipment (UNCLE) facility at Oak Ridge National Laboratory was employed to simulate the full-scale operating conditions of a purified uranium-bearing aqueous stream exiting the solvent extraction process in an NUCP. Nondestructive assay techniques using gamma-ray spectroscopy were evaluated to determine their viability as a technical means for drawing safeguards conclusions at NUCPs, and if the IAEA detection requirements of 1 significant quantity (SQ) can be met in a timely way. This work investigated gamma-ray signatures of uranyl nitrate circulating in the UNCLE facility and evaluated various gamma-ray detector sensitivities to uranyl nitrate. These detector validation activities include assessing detector responses to the uranyl nitrate gamma-ray signatures for spectrometers based on sodium iodide, lanthanum bromide, and high-purity germanium detectors. The results of measurements under static and dynamic operating conditions at concentrations ranging from 10-90 g U/L of natural uranyl nitrate are presented. A range of gamma-ray lines is

  2. The Utility of Continuous Temperature Monitoring of Refrigerators in a Long-Term Care Facility.

    PubMed

    Worz, Chad; Postolski, Josh; Williams, Kevin

    2017-04-01

    It is the current practice in most long-term care facilities to use manual logs when documenting refrigerator temperatures. This process is commonly associated with poor or fabricated compliance, little oversight, and documentation errors, both because of overt omissions and unsubstantiated values. It is also well-established that medication storage requirements are mandated by the Centers for Medicare & Medicaid Services (CMS). This analysis demonstrates the potential risk of poor cold-chain management of medications and establishes the possible utility of digitally recorded continuous temperature monitoring over manual logs. This small case-oriented review of a large nursing facility's storage process attempts to expose the risk associated with improper medication storage. The primary outcome of the study was to determine if a difference existed between temperature logs completed manually compared with those done with a continuous monitor. American Thermal Instruments (ATI) thermometers were placed into each of the existing refrigerators in a 147-bed nursing facility. Through a mobile app, the data recorded in each refrigerator were compiled into daily reports. Data were collected from a total of 12 refrigerators, 3 of which were medication refrigerators. Logging intervals were done over a 263-minute period and compiled the lowest recorded temperature, highest recorded temperature, and the average temperature for each refrigerator. In addition, reports showing the real-time results were compiled using the ATI DataNow service. All of the refrigerators analyzed had highest temperature recorded readings exceeding the maximum allowable temperature (50°F for refrigerator). All of the refrigerators had lowest temperature recorded readings below the minimum allowable temperature (32°F for refrigerators). All of the refrigerators also reported average temperatures outside of the allowable temperature range. The results necessitated the replacement of a refrigerator and

  3. Assisted living nursing practice: medication management: part 2 supervision and monitoring of medication administration by unlicensed assistive personnel.

    PubMed

    Mitty, Ethel; Flores, Sandi

    2007-01-01

    More than half the states permit assistance with or administration of medications by unlicensed assistive personnel or med techs. Authorization of this nursing activity (or task) is more likely because of state assisted living regulation than by support and approval of the state Board of Nursing. In many states, the definition of "assistance with" reads exactly like "administration of" thereby raising concern with regard to delegation, accountability, and liability for practice. It is, as well, a hazardous path for the assisted living nurse who must monitor and evaluate the performance of the individual performing this nursing task. This article, the second in a series on medication management, addresses delegation, standards of practice of medication administration, types of medication errors, the components of a performance evaluation tool, and a culture of safety. Maintaining professional standards of assisted living nursing practice courses throughout the suggested recommendations.

  4. Rehabilitation Facilities in Ontario

    PubMed Central

    Godfrey, C. M.; Jousse, A. T.

    1963-01-01

    Rehabilitation centres in Ontario were surveyed and categorized as in-patient and outpatient services, specialized centres for particular diseases, and vocational retraining centres. It is evident that many gaps exist in the pattern of rehabilitation facilities and services in the province. In some areas the facilities are grouped too closely together, necessitating transport of patients from great distances. The serious shortage of trained personnel is noted. There is little provision for mentally ill patients in existing rehabilitation centres. The use of mobile clinics is discussed. There is no evidence of duplication of services among those at present available. PMID:14077812

  5. Electromagnetic propulsion test facility

    NASA Technical Reports Server (NTRS)

    Gooder, S. T.

    1984-01-01

    A test facility for the exploration of electromagnetic propulsion concept is described. The facility is designed to accommodate electromagnetic rail accelerators of various lengths (1 to 10 meters) and to provide accelerating energies of up to 240 kiloJoules. This accelerating energy is supplied as a current pulse of hundreds of kiloAmps lasting as long as 1 millisecond. The design, installation, and operating characteristics of the pulsed energy system are discussed. The test chamber and its operation at pressures down to 1300 Pascals (10 mm of mercury) are described. Some aspects of safety (interlocking, personnel protection, and operating procedures) are included.

  6. Monitoring potential ecological impacts of a utility-scale photovoltaic panel facility on a creosote-bursage plant community

    NASA Astrophysics Data System (ADS)

    Apodaca, L.; Devitt, D. A.

    2016-12-01

    High energy demands and greater financial viability have propelled recent growth in the solar energy market. Southern Nevada is poised to become a major contributor of green energy through the commissioning of public and private lands for solar development, but there exists a pressing need to better understand the ecological consequences of these facilities as documentation of the impacts of large-scale solar operations on surrounding environments is severely lacking. The Copper Mountain 2 (CM2) solar facility in Eldorado Valley, Nevada, USA utilizes nearly 1.8 square kilometers of photovoltaic panels to generate enough energy to power about 50,000 homes and is situated within a predominately creosote (Larrea tridentata) and white bursage (Ambrosia dumosa) habitat. Currently, the potential impacts on the local environment related to this massive development are being studied from two perspectives: microclimate effects and alteration of surface hydrology. A series of meteorological towers and ibuttons are being used to monitor microclimate changes in the area of CM2 and the adjacent natural habitat as localized climate within the facility may be altering growing conditions in nearby desert plant communities. Because the placement of CM2 represents a major obstacle to established surface water flow, a transect of soil moisture probe access tubes have been placed in association with creosote plants along a downslope gradient from the facility to observe changes to soil water storage. Individual creosote and bursage plant physiologies are also being monitored to study any potential increase in plant stress influenced by the CM2 solar facility. Most measurements have been ongoing for at least one year. Greater details on the research infrastructure will be presented along with the latest observational data.

  7. Reliability in individual monitoring service.

    PubMed

    Mod Ali, N

    2011-03-01

    As a laboratory certified to ISO 9001:2008 and accredited to ISO/IEC 17025, the Secondary Standard Dosimetry Laboratory (SSDL)-Nuclear Malaysia has incorporated an overall comprehensive system for technical and quality management in promoting a reliable individual monitoring service (IMS). Faster identification and resolution of issues regarding dosemeter preparation and issuing of reports, personnel enhancement, improved customer satisfaction and overall efficiency of laboratory activities are all results of the implementation of an effective quality system. Review of these measures and responses to observed trends provide continuous improvement of the system. By having these mechanisms, reliability of the IMS can be assured in the promotion of safe behaviour at all levels of the workforce utilising ionising radiation facilities. Upgradation of in the reporting program through a web-based e-SSDL marks a major improvement in Nuclear Malaysia's IMS reliability on the whole. The system is a vital step in providing a user friendly and effective occupational exposure evaluation program in the country. It provides a higher level of confidence in the results generated for occupational dose monitoring of the IMS, thus, enhances the status of the radiation protection framework of the country.

  8. Inhalation and Ingestion Intakes with Associated Dose Estimates for Level II and Level III Personnel Using Capstone Study Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Szrom, Fran; Falo, Gerald A.; Lodde, Gordon M.

    2009-03-01

    Depleted uranium (DU) intake rates and subsequent dose rates were estimated for personnel entering armored combat vehicles perforated with DU penetrators (level II and level III personnel) using data generated during the Capstone Depleted Uranium (DU) Aerosol Study. Inhalation intake rates and associated dose rates were estimated from cascade impactors worn by sample recovery personnel and from cascade impactors that served as area monitors. Ingestion intake rates and associated dose rates were estimated from cotton gloves worn by sample recovery personnel and from wipe test samples from the interior of vehicles perforated with large caliber DU munitions. The mean DUmore » inhalation intake rate for level II personnel ranged from 0.447 mg h-1 based on breathing zone monitor data (in and around a perforated vehicle) to 14.5 mg h-1 based on area monitor data (in a perforated vehicle). The mean DU ingestion intake rate for level II ranged from 4.8 mg h-1 to 38.9 mg h-1 based on the wipe test data including surface to glove transfer factors derived from the Capstone data. Based on glove contamination data, the mean DU ingestion intake rates for level II and level III personnel were 10.6 mg h-1 was and 1.78 mg h-1, respectively. Effective dose rates and peak kidney uranium concentration rates were calculated based on the intake rates. The peak kidney uranium concentration rate cannot be multiplied by the total exposure duration when multiple intakes occur because uranium will clear from the kidney between the exposures.« less

  9. Flood monitoring network in southeastern Louisiana

    USGS Publications Warehouse

    McCallum, Brian E.

    1994-01-01

    A flood monitoring network has been established to alert emergency operations personnel and the public about hydrologic conditions in the Amite River Basin. The U.S. Geological Survey (USGS), in cooperation with the Louisiana Office of Emergency Preparedness (LOEP), has installed a real-time data acquisition system to monitor rainfall and river stages in the basin. These data will be transmitted for use by emergency operations personnel to develop flood control and evacuation strategies. The current river stages at selected gaging stations in the basin also will be broadcast by local television and radio stations during a flood. Residents can record the changing river stages on a basin monitoring map, similar to a hurricane tracking map.

  10. [A guide to good practice for information security in the handling of personal health data by health personnel in ambulatory care facilities].

    PubMed

    Sánchez-Henarejos, Ana; Fernández-Alemán, José Luis; Toval, Ambrosio; Hernández-Hernández, Isabel; Sánchez-García, Ana Belén; Carrillo de Gea, Juan Manuel

    2014-04-01

    The appearance of electronic health records has led to the need to strengthen the security of personal health data in order to ensure privacy. Despite the large number of technical security measures and recommendations that exist to protect the security of health data, there is an increase in violations of the privacy of patients' personal data in healthcare organizations, which is in many cases caused by the mistakes or oversights of healthcare professionals. In this paper, we present a guide to good practice for information security in the handling of personal health data by health personnel, drawn from recommendations, regulations and national and international standards. The material presented in this paper can be used in the security audit of health professionals, or as a part of continuing education programs in ambulatory care facilities. Copyright © 2013 Elsevier España, S.L. All rights reserved.

  11. Cavity beam position monitor system for the Accelerator Test Facility 2

    NASA Astrophysics Data System (ADS)

    Kim, Y. I.; Ainsworth, R.; Aryshev, A.; Boogert, S. T.; Boorman, G.; Frisch, J.; Heo, A.; Honda, Y.; Hwang, W. H.; Huang, J. Y.; Kim, E.-S.; Kim, S. H.; Lyapin, A.; Naito, T.; May, J.; McCormick, D.; Mellor, R. E.; Molloy, S.; Nelson, J.; Park, S. J.; Park, Y. J.; Ross, M.; Shin, S.; Swinson, C.; Smith, T.; Terunuma, N.; Tauchi, T.; Urakawa, J.; White, G. R.

    2012-04-01

    The Accelerator Test Facility 2 (ATF2) is a scaled demonstrator system for final focus beam lines of linear high energy colliders. This paper describes the high resolution cavity beam position monitor (BPM) system, which is a part of the ATF2 diagnostics. Two types of cavity BPMs are used, C-band operating at 6.423 GHz, and S-band at 2.888 GHz with an increased beam aperture. The cavities, electronics, and digital processing are described. The resolution of the C-band system with attenuators was determined to be approximately 250 nm and 1μm for the S-band system. Without attenuation the best recorded C-band cavity resolution was 27 nm.

  12. Energy Conservation for School Custodial and Maintenance Personnel. Course Outline and Instructional Materials.

    ERIC Educational Resources Information Center

    Anderson, Calvin E.

    Presented are materials prepared for the inservice education of school maintenance personnel on the subject of energy conservation in school facilities operations. The course is designed to help maintenance staff understand their schools' energy usage and formulate plans to control that usage. Among the topics covered are building inventory,…

  13. Prevalence and risk factors of female sexual dysfunction among healthcare personnel in Malaysia.

    PubMed

    Grewal, Gurdeep Singh; Gill, Jesjeet Singh; Sidi, Hatta; Gurpreet, Kaur; Jambunathan, Stephen Thevanathan; Suffee, Nusrat J; Midin, Marhani; Nik Jaafar, Nik Ruzyanei; Das, Srijit

    2014-01-01

    To determine the prevalence and risk factors of female sexual dysfunction (FSD) among healthcare personnel in selected healthcare facilities in Malaysia. This was a cross-sectional study carried out at three large healthcare facilities that were selected by convenience sampling. Within each facility, stratified random sampling was used to select suitable candidates to participate in the study (n=201). Validated questionnaires were used to assess depression, anxiety, sexual function in women and erectile dysfunction (ED) in their partners. The prevalence of FSD was 5.5%. Women with sexual dysfunction were more likely to be married longer (OR=4.08; 95% CI; 1.15-4.50), had lower frequency of sexual intercourse (OR=5.00; 95% C; 1.05-23.76) and had a spouse with ED (OR=24.35; 95% CI; 4.55-130.37). Multivariate analysis showed that ED was the strongest predictor for FSD (AOR=27.30; 95% CI; 4.706-159.08). One in eighteen female healthcare personnel suffered from FSD and presence of ED in the partner strongly impacted her sexual function, negatively. The findings highlight the importance of including the male partner in clinical assessment of FSD. Copyright © 2014 Elsevier Inc. All rights reserved.

  14. Screening for Atrial Fibrillation in Patients ≥65 Years Using an Automatic Blood Pressure Monitor in a Skilled Nursing Facility.

    PubMed

    Wiesel, Joseph; Salomone, Thomas J

    2017-10-15

    Early detection of asymptomatic atrial fibrillation (AF) provides an opportunity to treat patients to reduce their risk of stroke. Long-term residents of skilled nursing facilities frequently have multiple risk factors for strokes due to AF and may benefit from screening for AF. Patients in a skilled nursing facility 65 years and older, without a history of AF and without a pacemaker or defibrillator, were evaluated using a Microlife WatchBP Home A automatic blood pressure monitor that can detect AF when set to a triple reading mode. Those with readings positive for AF were evaluated with a standard 12-lead electrocardiogram (ECG) or a 30-second single-channel ECG to confirm the presence of AF. A total of 101 patients were screened with an average age of 78 years, and 48 (48%) were female. Nine automatic blood pressure monitor readings were positive for possible AF. Of those, 7 (6.9%, 95% confidence intervals 3.0% to 14.2%) had AF confirmed with ECG. Only 2 (2%, 95% confidence interval 0.3% to 7.7%) were false-positive readings. One-time screening for AF using an automatic blood pressure monitor in a skilled nursing facility resulted in a high number of patients with newly diagnosed AF. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Implementation and Impact of an Automated Group Monitoring and Feedback System to Promote Hand Hygiene Among Health Care Personnel

    PubMed Central

    Conway, Laurie J.; Riley, Linda; Saiman, Lisa; Cohen, Bevin; Alper, Paul; Larson, Elaine L.

    2015-01-01

    Article-at-a-Glance Background Despite substantial evidence to support the effectiveness of hand hygiene for preventing health care–associated infections, hand hygiene practice is often inadequate. Hand hygiene product dispensers that can electronically capture hand hygiene events have the potential to improve hand hygiene performance. A study on an automated group monitoring and feedback system was implemented from January 2012 through March 2013 at a 140-bed community hospital. Methods An electronic system that monitors the use of sanitizer and soap but does not identify individual health care personnel was used to calculate hand hygiene events per patient-hour for each of eight inpatient units and hand hygiene events per patient-visit for the six outpatient units. Hand hygiene was monitored but feedback was not provided during a six-month baseline period and three-month rollout period. During the rollout, focus groups were conducted to determine preferences for feedback frequency and format. During the six-month intervention period, graphical reports were e-mailed monthly to all managers and administrators, and focus groups were repeated. Results After the feedback began, hand hygiene increased on average by 0.17 events/patient-hour in inpatient units (interquartile range = 0.14, p = .008). In outpatient units, hand hygiene performance did not change significantly. A variety of challenges were encountered, including obtaining accurate census and staffing data, engendering confidence in the system, disseminating information in the reports, and using the data to drive improvement. Conclusions Feedback via an automated system was associated with improved hand hygiene performance in the short term. PMID:25252389

  16. Implementation and impact of an automated group monitoring and feedback system to promote hand hygiene among health care personnel.

    PubMed

    Conway, Laurie J; Riley, Linda; Saiman, Lisa; Cohen, Bevin; Alper, Paul; Larson, Elaine L

    2014-09-01

    Despite substantial evidence to support the effectiveness of hand hygiene for preventing health care-associated infections, hand hygiene practice is often inadequate. Hand hygiene product dispensers that can electronically capture hand hygiene events have the potential to improve hand hygiene performance. A study on an automated group monitoring and feedback system was implemented from January 2012 through March 2013 at a 140-bed community hospital. An electronic system that monitors the use of sanitizer and soap but does not identify individual health care personnel was used to calculate hand hygiene events per patient-hour for each of eight inpatient units and hand hygiene events per patient-visit for the six outpatient units. Hand hygiene was monitored but feedback was not provided during a six-month baseline period and three-month rollout period. During the rollout, focus groups were conducted to determine preferences for feedback frequency and format. During the six-month intervention period, graphical reports were e-mailed monthly to all managers and administrators, and focus groups were repeated. After the feedback began, hand hygiene increased on average by 0.17 events/patient-hour in inpatient units (interquartile range = 0.14, p = .008). In outpatient units, hand hygiene performance did not change significantly. A variety of challenges were encountered, including obtaining accurate census and staffing data, engendering confidence in the system, disseminating information in the reports, and using the data to drive improvement. Feedback via an automated system was associated with improved hand hygiene performance in the short-term.

  17. Generalized Monitoring Facility. Users Manual.

    DTIC Science & Technology

    1982-05-01

    based monitor. The RMC will sample system queues and tables on a 30-second time interval. The data captured from these queues and cells are written...period, only the final change will be reported. The following communication region cells are constantly monitored for changes, since a processor...is reported as zeros in WW6.4. When GMC terminates, it writes a record containing information read from communication region cells and information

  18. Simulation and monitoring tools to protect disaster management facilities against earthquakes

    NASA Astrophysics Data System (ADS)

    Saito, Taiki

    2017-10-01

    The earthquakes that hit Kumamoto Prefecture in Japan on April 14 and 16, 2016 severely damaged over 180,000 houses, including over 8,000 that were completely destroyed and others that were partially damaged according to the Cabinet Office's report as of November 14, 2016 [1]. Following these earthquakes, other parts of the world have been struck by earthquakes including Italy and New Zealand as well as the central part of Tottori Prefecture in October, where the earthquake-induced collapse of buildings has led to severe damage and casualties. The earthquakes in Kumamoto Prefecture, in fact, damaged various disaster management facilities including Uto City Hall, which significantly hindered the city's evacuation and recovery operations. One of the most crucial issues in times of disaster is securing the functions of disaster management facilities such as city halls, hospitals and fire stations. To address this issue, seismic simulations are conducted on the East and the West buildings of Toyohashi City Hall using the analysis tool developed by the author, STERA_3D, with the data of the ground motion waveform prediction for the Nankai Trough earthquake provided by the Ministry of Land, Infrastructure, Transport and Tourism. As the result, it was found that the buildings have sufficient earthquake resistance. It turned out, however, that the west building is at risk for wall cracks or ceiling panel's collapse while in the east building, people would not be able to stand through the strong quakes of 7 on the seismic intensity scale and cabinets not secured to the floors or walls would fall over. Additionally, three IT strong-motion seismometers were installed in the city hall to continuously monitor vibrations. Every five minutes, the vibration data obtained by the seismometers are sent to the computers in Toyohashi University of Technology via the Internet for the analysis tools to run simulations in the cloud. If an earthquake strikes, it is able to use the results

  19. 42 CFR 9.9 - Facility staffing.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... CHIMPANZEES HELD IN THE FEDERALLY SUPPORTED SANCTUARY SYSTEM § 9.9 Facility staffing. How many personnel are required to staff the chimpanzee sanctuary and what qualifications and training must the staff possess? (a... of the activities and chimpanzee population of the sanctuary. The level of staffing shall be adequate...

  20. 42 CFR 9.9 - Facility staffing.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... CHIMPANZEES HELD IN THE FEDERALLY SUPPORTED SANCTUARY SYSTEM § 9.9 Facility staffing. How many personnel are required to staff the chimpanzee sanctuary and what qualifications and training must the staff possess? (a... of the activities and chimpanzee population of the sanctuary. The level of staffing shall be adequate...

  1. 42 CFR 9.9 - Facility staffing.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... CHIMPANZEES HELD IN THE FEDERALLY SUPPORTED SANCTUARY SYSTEM § 9.9 Facility staffing. How many personnel are required to staff the chimpanzee sanctuary and what qualifications and training must the staff possess? (a... of the activities and chimpanzee population of the sanctuary. The level of staffing shall be adequate...

  2. 42 CFR 9.9 - Facility staffing.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... CHIMPANZEES HELD IN THE FEDERALLY SUPPORTED SANCTUARY SYSTEM § 9.9 Facility staffing. How many personnel are required to staff the chimpanzee sanctuary and what qualifications and training must the staff possess? (a... of the activities and chimpanzee population of the sanctuary. The level of staffing shall be adequate...

  3. 5 CFR 9901.409 - Monitoring and developing performance.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... LABOR RELATIONS SYSTEMS (DEPARTMENT OF DEFENSE-OFFICE OF PERSONNEL MANAGEMENT) DEPARTMENT OF DEFENSE NATIONAL SECURITY PERSONNEL SYSTEM (NSPS) Performance Management § 9901.409 Monitoring and developing performance. (a) In applying the requirements of the performance management system and its implementing...

  4. 5 CFR 9901.409 - Monitoring and developing performance.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... LABOR RELATIONS SYSTEMS (DEPARTMENT OF DEFENSE-OFFICE OF PERSONNEL MANAGEMENT) DEPARTMENT OF DEFENSE NATIONAL SECURITY PERSONNEL SYSTEM (NSPS) Performance Management § 9901.409 Monitoring and developing performance. (a) In applying the requirements of the performance management system and its implementing...

  5. [Implementation of the new drinking water regulation section sign 18: monitoring of drinking water systems in houses--water for public use].

    PubMed

    Hentschel, W; Voigt, K; Heudorf, U

    2006-08-01

    The monitoring of drinking water based on the drinking water regulation is one of the central tasks of public health authorities in Germany. With the coming into force of the new drinking water regulation in the year 2003 also water supply plants "from which water is made available for the public, in particular in schools, kindergartens, hospitals, restaurants and other communal facilities" must be supervised for the first time (TrinkwV section sign 18). Thus, for Frankfurt/Main the number of the facilities/objects which are to be supervised rose from approx. 300 to approx. 4,700. Since appropriate expansion of personnel was not possible, innovative solutions were in demand for implementation of these tasks. These are introduced here.

  6. Monitoring System for the Gold Target by Radiation Detectors in Hadron Experimental Facility at J-PARC

    NASA Astrophysics Data System (ADS)

    Muto, Ryotaro; Agari, Keizo; Aoki, Kazuya; Bessho, Kotaro; Hagiwara, Masayuki; Hirose, Erina; Ieiri, Masaharu; Iwasaki, Ruri; Katoh, Yohji; Kitagawa, Jun-ichi; Minakawa, Michifumi; Morino, Yuhei; Saito, Kiwamu; Sato, Yoshinori; Sawada, Shin'ya; Shirakabe, Yoshihisa; Suzuki, Yoshihiro; Takahashi, Hitoshi; Tanaka, Kazuhiro; Toyoda, Akihisa; Watanabe, Hiroaki; Yamanoi, Yutaka

    2017-09-01

    At the Hadron Experimental Facility in J-PARC, we inject a 30-GeV proton beam into a gold target to produce secondary particle beams required for various particle and nuclear physics experiments. The gold target is placed in a hermetic chamber, and helium gas is circulated in the chamber to monitor the soundness of the target. The radioactivity in helium gas is continuously monitored by gamma-ray detectors such as a germanium detector and a NaI(Tl) detector. Beam operations with those target-monitoring systems were successfully performed from April to June and October to December 2015, and from May to June 2016. In this paper, the details of the helium gas circulation system and gamma-ray detectors and the analysis results of the obtained gamma-ray spectra are reported.

  7. A Behavioral Approach to Meeting Contingency Contracting Personnel Requirements

    DTIC Science & Technology

    2009-03-01

    any increase in performance or in apparent job satisfaction is misleading. For in these instances the removal of a decrement in performance by the...Personnel Requirements 6. AUTHOR(S) Jacob Chieffo 5. FUNDING NUMBERS 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) Naval Postgraduate School...Monterey, CA 93943-5000 8. PERFORMING ORGANIZATION REPORT NUMBER 9. SPONSORING / MONITORING AGENCY NAME(S) AND ADDRESS(ES) N/A 10

  8. Drainage facility management system : final report, June 2009.

    DOT National Transportation Integrated Search

    2009-06-01

    This research project identified requirements for a drainage facility management system for the Oregon Department of Transportation. It also estimated the personnel resources needed to collect the inventory to populate such a system with data. A tota...

  9. McNary Dam, Ice Harbor Dam, and Lower Monumental Dam Smolt Monitoring Program; 1996 Annual Report.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hillson, Todd; Lind, Sharon; Price, William

    1997-07-01

    The Washington Department of Fish & Wildlife (WDFW) assumed responsibility for the Smolt Monitoring Program at McNary Dam on the Columbia River in 1990 and at the new juvenile collection facility at Lower Monumental Dam on the Snake River in 1993. In 1996, Smolt Monitoring Program activities also began at the new juvenile collection facility located at Ice Harbor Dam. This report summarizes the 1996 Smolt Monitoring work at all three sites. The work at Ice Harbor consisted of Gas Bubble Trauma (GBT) monitoring only. In general, the 1996 passage season at both the McNary and Lower Monumental sites canmore » be characterized by reduced passage of juveniles through the collection systems due to elevated river flows and spill, and low (<1%) overall facility mortality rates most likely resulting from cooler water temperatures. In accordance with the National Marine Fisheries Service recommendations (NMFS, 1995) all spring migrants were bypassed at McNary Dam in 1996. Mechanical problems within the McNary collection system resulted in collection and sampling activities being delayed until April 18 at this site, while sampling and collection began on the scheduled starting date of April 1 at Lower Monumental Dam. Monitoring operations were conducted through December 14 at McNary Dam and through October 28 at Lower Monumental Dam. An ongoing transportation evaluation summer migrant marking program was conducted at McNary Dam in 1996 by the NMFS. This necessitated the sampling of 394,211 additional fish beyond the recommended sampling guidelines. All total, 509,237 and 31,219 juvenile salmonids were anesthetized and individually counted, examined for scale loss, injuries, and brands by WDFW Smolt Monitoring personnel in 1996 at McNary Dam and Lower Monumental Dam, respectively.« less

  10. The Development of a Beta-Gamma Personnel Dosimeter

    NASA Astrophysics Data System (ADS)

    Tsakeres, Frank Steven

    The assessment of absorbed dose in mixed beta and gamma radiation fields is an extremely complex task. For many years, the assessment of the absorbed dose to tissue from the weakly penetrating components of a radiation field (i.e., beta particles, electrons) has been largely ignored. Beta radiation fields are encountered routinely in a nuclear facility and may represent the major radiation component under certain accident or emergency conditions. Many attempts have been made to develop an accurate mixed field personnel dosimeter. However, all of these dosimeters have exhibited numerous response problems which have limited their usefulness for personnel dose assessment. Consequently, the determination of the absorbed dose at the epidermal depth (i.e., 7 mg/cm('2)) has been difficult to measure accurately. The objective of this research project was to design, build, and test a sensitive and accurate personnel dosimeter for mixed field applications. The selection of the various dosimeter elements were determined by evaluating several types of phosphors, filters, and backscatter materials. After evaluating the various response characteristics of the badge components, a prototype dosimeter, the CHEMM (CaF(,2):Dy Highly Efficient Multiple Element Multiple Filter) personnel dosimeter, was developed and tested at Georgia Tech, Emory University and the National Bureau of Standards. This dosimeter was comprised of four large CaF(,2):Dy (TLD-200) TLD's and a standard LiF (TLD-100) chip. The weakly penetrating and penetrating components of a radiation field were separated using a series of TLD/filter combinations and a new dose assessment algorithm. The large TLD-200 chips, along with a series of tissue-equivalent filters, were used to determine the absorbed dose due to the weakly penetrating radiation while a LiF/filter combination was used to measure the penetrating component. In addition, a new backscatter material was included in the badge design to better simulate a

  11. Cold Vacuum Drying facility civil structural system design description (SYS 06)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    PITKOFF, C.C.

    This document describes the Cold Vacuum Drying (CVD) Facility civil - structural system. This system consists of the facility structure, including the administrative and process areas. The system's primary purpose is to provide for a facility to house the CVD process and personnel and to provide a tertiary level of containment. The document provides a description of the facility and demonstrates how the design meets the various requirements imposed by the safety analysis report and the design requirements document.

  12. Accessibility to Laboratories and Equipment for the Physically Handicapped: A Handbook for Vocational Education Personnel.

    ERIC Educational Resources Information Center

    Erekson, Thomas L.; And Others

    Intended to assist Illinois educational personnel to provide vocational education services for students with physical disabilities, the handbook's eight sections focus on program and facility modification to accommodate physically disabled students in regular vocational education programs. Section I introduces the topic, provides an historical…

  13. Contamination Impact of Station Brush Fire on Cleanroom Facilities

    NASA Technical Reports Server (NTRS)

    Carey, Phil; Blakkolb, Brian

    2010-01-01

    Brush and forest fires, both naturally occurring and anthropogenic in origin, in proximity to space flight hardware processing facilities raise concerns about the threat of contamination resulting from airborne particulate and molecular components of smoke. Perceptions of the severity of the threat are possibly heightened by the high sensitivity of the human sense of smell to some components present in the smoke of burning vegetation.On August 26th, 2009, a brushfire broke out north of Pasadena, California, two miles from the Jet Propulsion Laboratory. The Station Fire destroyed over 160,000 acres, coming within a few hundred yards of JPL. Smoke concentrations on Lab were very heavy over several days. All Lab operations were halted, and measures were taken to protect personnel, critical hardware, and facilities. Evaluation of real-time cleanroom monitoring data, visualinspection of facilities, filter systems, and analysis of surface cleanliness samples revealed facility environments andhardware were minimally effected.Outside air quality easily exceeded Class Ten Million. Prefilters captured most large ash and soot; multi-stage filtration greatly minimized the impact on the HEPA/ULPA filters. Air quality in HEPA filtered spacecraft assembly cleanrooms remained within Class 10,000 specification throughout. Surface cleanliness was inimally affected, as large particles were effectively removed from the airstream, and sub-micron particles have extremely long settling rates. Approximate particulate fallout within facilities was 0.00011% area coverage/day compared to 0.00038% area coverage/day during normal operations. Deposition of condensable airborne components, as measured in real time, peaked at approximately1.0 ng/cm2/day compared to 0.05 ng/cm2/day nominal.

  14. Contamination impact of station brush fire on cleanroom facilities

    NASA Astrophysics Data System (ADS)

    Carey, Philip A.; Blakkolb, Brian K.

    2010-08-01

    Brush and forest fires, both naturally occurring and anthropogenic in origin, in proximity to space flight hardware processing facilities raise concerns about the threat of contamination resulting from airborne particulate and molecular components of smoke. Perceptions of the severity of the threat are possibly heightened by the high sensitivity of the human sense of smell to some components present in the smoke of burning vegetation. On August 26th, 2009, a brushfire broke out north of Pasadena, California, two miles from the Jet Propulsion Laboratory. The Station Fire destroyed over 160,000 acres, coming within a few hundred yards of JPL. Smoke concentrations on Lab were very heavy over several days. All Lab operations were halted, and measures were taken to protect personnel, critical hardware, and facilities. Evaluation of real-time cleanroom monitoring data, visual inspection of facilities, filter systems, and analysis of surface cleanliness samples revealed facility environments and hardware were minimally effected. Outside air quality easily exceeded Class Ten Million. Prefilters captured most large ash and soot; multi-stage filtration greatly minimized the impact on the HEPA/ULPA filters. Air quality in HEPA filtered spacecraft assembly cleanrooms remained within Class 10,000 specification throughout. Surface cleanliness was minimally affected, as large particles were effectively removed from the airstream, and sub-micron particles have extremely long settling rates. Approximate particulate fallout within facilities was 0.00011% area coverage/day compared to 0.00038% area coverage/day during normal operations. Deposition of condensable airborne components, as measured in real time, peaked at approximately 1.0 ng/cm2/day compared to 0.05 ng/cm2/day nominal.

  15. Personnel Management.

    ERIC Educational Resources Information Center

    Naval Personnel Program Support Activity, Washington, DC.

    The document serves as a basic text for the indoctrination of all naval officers and as an introductory text for the officer who specializes in personnel administration or manpower management. Chapter 1 contains an introductory summary of the various functions of naval personnel administration and manpower management and describes the processes of…

  16. Ground-water monitoring compliance projects for Hanford Site facilities: Progress Report for the Period July 1 to September 30, 1987

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1987-11-01

    This report documents the progress of four Hanford Site ground-water monitoring projects for the period from July 1 to September 310, 1987. The four disposal facilities are the 300 Area Process Trenches, 183-H Solar Evaporation Basins, 200 Area Low-Level Burial Grounds, and Nonradioactive Dangerous Waste (NRDW) Landfill. This report is the fifth in a series of periodic status reports. During this reporting period, field activities consisted of completing repairs on five monitoring wells originally present around the 183-H Basins and completing construction of 25 monitoring wells around the 200 Area Burial Grounds. The 14 wells in the 200 East Areamore » were completed by Kaiser Engineers Hanford (KEH) and the 11 wells in the 200 West Area were compelted by ONWEGO Well Drilling. The NRDW Landfill interim characterization report was submitted to the WDOE and the USEPA in August 1987. Analytical results for the 300 Area, 183-H, and the NRDW Landfill indicate no deviations from previously established trends. Results from the NRDW Land-fill indiate that the facility has no effect on the ground-water quality beneath the facility, except for the detection of coliform bacteria. A possible source of this contamination is the solid-waste lanfill (SWL) adjacent to the NRDW Landfill. Ground-water monitoring data for the NRDW and SWL will be evaluated together in the future. Aquifer testing was completed in the 25 new wells surrounding the 200 Area buiral grounds. 13 refs., 19 refs., 13 tabs.« less

  17. Development of Monitors for Assessing Exposure of Military Personnel to Toxic Chemicals.

    DTIC Science & Technology

    2000-01-01

    Residues " S ampler Preparation 7 Transfer and Analysis 7 Temperature Effects on PIMS Sampling Rate 8 Environmental Air Sampling 8 Results and...of exposure and potential toxicity to personnel. While progress has been made in improving active water and air sampling technology, such devices...streams, 3) the apparatus is also applicable for use in air sampling deployments in indoor and outdoor scenarios, and 4) the apparatus is commercially

  18. Antenna Test Facility (ATF): User Test Planning Guide

    NASA Technical Reports Server (NTRS)

    Lin, Greg

    2011-01-01

    Test process, milestones and inputs are unknowns to first-time users of the ATF. The User Test Planning Guide aids in establishing expectations for both NASA and non-NASA facility customers. The potential audience for this guide includes both internal and commercial spaceflight hardware/software developers. It is intended to assist their test engineering personnel in test planning and execution. Material covered includes a roadmap of the test process, roles and responsibilities of facility and user, major milestones, facility capabilities, and inputs required by the facility. Samples of deliverables, test article interfaces, and inputs necessary to define test scope, cost, and schedule are included as an appendix to the guide.

  19. Client-centered design of residential addiction and mental health care facilities: staff perceptions of their work environment.

    PubMed

    Novotná, Gabriela; Urbanoski, Karen A; Rush, Brian R

    2011-11-01

    In this article we discuss the findings from a series of focus groups conducted as part of a 3-year, mixed-method evaluation of clinical programs in a large mental health and substance use treatment facility in Canada. We examined the perceptions of clinical personnel on the physical design of new treatment units and the impact on service delivery and the work environment. The new physical design appeared to support client recovery and reduce stigma; however, it brought certain challenges. Participants reported a compromised ability to monitor clients, a lack of designated therapeutic spaces, and insufficient workspace for staff. They also thought that physical design positively facilitated communication and therapeutic relationships among clinicians and clients, and increased team cohesion. We suggest that, from these findings, new avenues for research on achieving the important balance between client and staff needs in health facility design can be explored.

  20. 5 CFR 9701.407 - Monitoring performance and providing feedback.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... feedback. 9701.407 Section 9701.407 Administrative Personnel DEPARTMENT OF HOMELAND SECURITY HUMAN RESOURCES MANAGEMENT SYSTEM (DEPARTMENT OF HOMELAND SECURITY-OFFICE OF PERSONNEL MANAGEMENT) DEPARTMENT OF HOMELAND SECURITY HUMAN RESOURCES MANAGEMENT SYSTEM Performance Management § 9701.407 Monitoring...

  1. Sleep Patterns of Naval Aviation Personnel Conducting Mine Hunting Operations

    DTIC Science & Technology

    2006-09-01

    Personnel Conducting Mine Hunting Operations 6. AUTHOR(S) Bennett Solberg 5. FUNDING NUMBERS 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES...Naval Postgraduate School Monterey, CA 93943-5000 8. PERFORMING ORGANIZATION REPORT NUMBER 9. SPONSORING /MONITORING AGENCY NAME(S) AND...human performance , resulting in predictable changes not only on the individual level but also on the system as a whole. This descriptive study

  2. Users Guide for the National Transonic Facility Research Data System

    NASA Technical Reports Server (NTRS)

    Foster, Jean M.; Adcock, Jerry B.

    1996-01-01

    The National Transonic Facility is a complex cryogenic wind tunnel facility. This report briefly describes the facility, the data systems, and the instrumentation used to acquire research data. The computational methods and equations are discussed in detail and many references are listed for those who need additional technical information. This report is intended to be a user's guide, not a programmer's guide; therefore, the data reduction code itself is not documented. The purpose of this report is to assist personnel involved in conducting a test in the National Transonic Facility.

  3. 44 CFR 312.6 - Materials and facilities.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... OF HOMELAND SECURITY PREPAREDNESS USE OF CIVIL DEFENSE PERSONNEL, MATERIALS, AND FACILITIES FOR... to, and does not detract from attack-related civil defense preparedness: (a) Materials provided and... contributions under the Act. (e) Equipment loaned or granted to the States for civil defense purposes (e.g...

  4. 44 CFR 312.6 - Materials and facilities.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... OF HOMELAND SECURITY PREPAREDNESS USE OF CIVIL DEFENSE PERSONNEL, MATERIALS, AND FACILITIES FOR... to, and does not detract from attack-related civil defense preparedness: (a) Materials provided and... contributions under the Act. (e) Equipment loaned or granted to the States for civil defense purposes (e.g...

  5. 44 CFR 312.6 - Materials and facilities.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... OF HOMELAND SECURITY PREPAREDNESS USE OF CIVIL DEFENSE PERSONNEL, MATERIALS, AND FACILITIES FOR... to, and does not detract from attack-related civil defense preparedness: (a) Materials provided and... contributions under the Act. (e) Equipment loaned or granted to the States for civil defense purposes (e.g...

  6. 44 CFR 312.6 - Materials and facilities.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... OF HOMELAND SECURITY PREPAREDNESS USE OF CIVIL DEFENSE PERSONNEL, MATERIALS, AND FACILITIES FOR... to, and does not detract from attack-related civil defense preparedness: (a) Materials provided and... contributions under the Act. (e) Equipment loaned or granted to the States for civil defense purposes (e.g...

  7. Navy-Wide Personnel Survey (NPS) 1991: Graphic Presentation of Results for Enlisted Personnel

    DTIC Science & Technology

    1992-07-01

    102 Foreword The Navy-wide Personnel Survey (NPS), which is administered annually, is one part of the Navy Personnel Survey System ( NPSS ) originated by...the Navy Personnel Research and Develop- ment Center. The NPSS is designed to manage and control Navy personnel surveys to minimize intrusion into...fleet and shore operations and to serve as a vehicle for attitude and survey research. The NPSS is composed of NPS, special surveys, and quick-response

  8. 42 CFR 52b.8 - How will NIH monitor the use of facilities constructed with federal funds?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false How will NIH monitor the use of facilities constructed with federal funds? 52b.8 Section 52b.8 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES GRANTS NATIONAL INSTITUTES OF HEALTH CONSTRUCTION GRANTS § 52b.8 How will NIH...

  9. 42 CFR 52b.8 - How will NIH monitor the use of facilities constructed with federal funds?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false How will NIH monitor the use of facilities constructed with federal funds? 52b.8 Section 52b.8 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES GRANTS NATIONAL INSTITUTES OF HEALTH CONSTRUCTION GRANTS § 52b.8 How will NIH...

  10. 42 CFR 52b.8 - How will NIH monitor the use of facilities constructed with federal funds?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false How will NIH monitor the use of facilities constructed with federal funds? 52b.8 Section 52b.8 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES GRANTS NATIONAL INSTITUTES OF HEALTH CONSTRUCTION GRANTS § 52b.8 How will NIH...

  11. 42 CFR 52b.8 - How will NIH monitor the use of facilities constructed with federal funds?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false How will NIH monitor the use of facilities constructed with federal funds? 52b.8 Section 52b.8 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES GRANTS NATIONAL INSTITUTES OF HEALTH CONSTRUCTION GRANTS § 52b.8 How will NIH...

  12. 42 CFR 52b.8 - How will NIH monitor the use of facilities constructed with federal funds?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false How will NIH monitor the use of facilities constructed with federal funds? 52b.8 Section 52b.8 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES GRANTS NATIONAL INSTITUTES OF HEALTH CONSTRUCTION GRANTS § 52b.8 How will NIH...

  13. Health consequences of shift-work: the case of iranian hospital security personnel.

    PubMed

    Abedini, Roghayeh; Soltanzadeh, Ahmad; Faghih, Mohammad Amin; Mohammadi, Heidar; Kamalinia, Mojtaba; Mohraz, Majid Habibi; Arassi, Maziyar; Veyseh, Peyman Piran; Aghaei, Hamed; Hosseini, Seyed Younes

    2015-01-01

    Shift-work, which is an ergonomics issue in workplaces, can negatively affect workers. The security personnel of medical centers in Iran have multiple responsibilities and consequently are exposed to such unwanted situations as observing patients, disputing with patient's attendants, unwanted shift schedules, and being away from family for long periods. This study assessed health problems of Iranian hospital security personnel (shift-worker personnel) using the Survey of Shift-workers (SOS) questionnaire (Persian version). This cross-sectional study was conducted in seven medical centers (4 hospitals and 3 clinics). A total of 416 workers were surveyed: shift-workers (exposed group) (n=209) and non-shift-workers (unexposed group) (n=207). The prevalence of adverse health effects was higher in shift-workers than day-workers. The level of education and mean Body Mass Index (BMI) in shift-workers were significantly higher compared with day-workers. The prevalence of gastrointestinal disorders, cardiovascular and psychological problems were also significantly higher in shift-workers compared with day-workers. Overall, the prevalence of health problems among the security personnel of medical centers was high. Hence, it is recommended that personnel be put under periodic monitoring and receive medical counseling and treatment if there is any disorder.

  14. Los Alamos County Fire Department LAFD: TA-55 PF-4 Facility Familiarization Tour, OJT 55260

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rutherford, Victor Stephen

    Los Alamos National Laboratory (LANL) will conduct familiarization tours for Los Alamos County Fire Department (LAFD) personnel at the Plutonium Facility (PF-4) at Technical Area (TA)-55. These familiarization tours are official LANL business; the purpose of these tours is to orient the firefighters to the facility so that they can respond efficiently and quickly to a variety of emergency situations. This orientation includes the ingress and egress of the area and buildings, layout and organization of the facility, evacuation procedures and assembly points, and areas of concern within the various buildings at the facility. LAFD firefighters have the skills andmore » abilities to perform firefighting operations and other emergency response tasks that cannot be provided by other LANL personnel who have the required clearance level. This handout provides details of the information, along with maps and diagrams, to be presented during the familiarization tours. The handout will be distributed to the trainees at the time of the tour. A corresponding checklist will also be used as guidance during the familiarization tours to ensure that all required information is presented to LAFD personnel.« less

  15. Evaluation of Portable Multi-Gas Analyzers for use by Safety Personnel

    NASA Technical Reports Server (NTRS)

    Lueck, D. E.; Meneghelli, B. J.; Bardel, D. N.

    1998-01-01

    During confined space entry operations as well as Shuttle-safing operations, United Space Alliance (USA)/National Aeronautics and Space Administration (NASA) safety personnel use a variety of portable instrumentation to monitor for hazardous levels of compounds such as nitrogen dioxide (N%), monomethylhydrazine (NMM), FREON 21, ammonia (NH3), oxygen (O2), and combustibles (as hydrogen (H2)). Except for O2 and H2, each compound is monitored using a single analyzer. In many cases these analyzers are 5 to 10 years old and require frequent maintenance. In addition, they are cumbersome to carry and tend to make the job of personnel monitoring physically taxing. As part of an effort to upgrade the sensor technology background information was requested from a total of 27 manufacturers of portable multi-gas instruments. A set of criteria was established to determine which vendors would be selected for laboratory evaluation. These criteria were based on requests made by USA/NASA Safety personnel in order to meet requirements within their respective areas for confined-space and Shuttle-safing operations. Each of the 27 manufacturers of multi-gas analyzers was sent a copy of the criteria and asked to fill in the appropriate information pertaining to their instrumentation. Based on the results of the sensor criteria worksheets, a total of 9 vendors out of 27 surveyed manufacturers were chosen for evaluation. Each vendor included in the final evaluation process was requested to configure each of two analyzers with NO2, NH3, O2, and combustible sensors. A set of lab tests was designed in order to determine which of the multi-gas instruments under evaluation was best suited for use in both shuttle and confined space operations. These tests included linearity/repeatability, zero/span drift response/recovery, humidity, interference, and maintenance. At the conclusion of lab testing three vendors were selected for additional field testing. Based on the results of both the lab and

  16. STS-32 MS Dunbar trains in JSC Manipulator Development Facility (MDF)

    NASA Technical Reports Server (NTRS)

    1989-01-01

    STS-32 Mission Specialist (MS) Bonnie J. Dunbar reviews checklist with training personnel in the Manipulator Development Facility (MDF) in JSC's Mockup and Integration Facility (MAIL) Bldg 9A. Dunbar (left) discusses procedures with trainer in front of the aft flight deck onorbit station controls. Overhead window W8 is visible above their heads.

  17. Space exploration initiative candidate nuclear propulsion test facilities

    NASA Technical Reports Server (NTRS)

    Baldwin, Darrell; Clark, John S.

    1993-01-01

    One-page descriptions for approximately 200 existing government, university, and industry facilities which may be available in the future to support SEI nuclear propulsion technology development and test program requirements are provided. To facilitate use of the information, the candidate facilities are listed both by location (Index L) and by Facility Type (Index FT). The included one-page descriptions provide a brief narrative description of facility capability, suggest potential uses for each facility, and designate a point of contact for additional information that may be needed in the future. The Nuclear Propulsion Office at NASA Lewis presently plans to maintain, expand, and update this information periodically for use by NASA, DOE, and DOD personnel involved in planning various phases of the SEI Nuclear Propulsion Project.

  18. Spacelab Data Processing Facility

    NASA Technical Reports Server (NTRS)

    1983-01-01

    The capabilities of the Spacelab Data Processing Facility (SPDPF) are highlighted. The capturing, quality monitoring, processing, accounting, and forwarding of vital Spacelab data to various user facilities around the world are described.

  19. CD-ROM nutrient analysis database assists self-monitoring behavior of active duty Air Force personnel receiving nutrition counseling for weight loss.

    PubMed

    Heetderks-Cox, M J; Alford, B B; Bednar, C M; Heiss, C J; Tauai, L A; Edgren, K K

    2001-09-01

    This study observed the effect of using a computerized vs manual method of self-monitoring among Air Force personnel receiving nutrition counseling for weight loss. Subjects who enrolled during the first 2 weeks of the 4-week recruitment period completed food records for 6 weeks using a CD-ROM nutrient database (intervention group) whereas those who enrolled during the last 2 weeks used a food record booklet (comparison group). Of the 42 subjects (n = 23 intervention group and n = 19 comparison group), only 113 intervention and 11 comparison group subjects (57% of study enrollees) submitted at least 1 food record during the study and were included in the analysis, which included review of pre- and poststudy questionnaires, food records, and focus group data. There were no significant differences between the number of days per week documented or average number of items recorded daily. All 9 intervention as compared to 2 comparison group subjects who completed a poststudy questionnaire searched for lower-energy and lower-fat items and reported changing their dietary intake as a result. All intervention group subjects who participated in a focus group (n=6) had favorable comments about using the CD-ROM for monitoring and changing eating habits, indicating that it is a beneficial self-monitoring tool. Participants enjoyed the immediate dietary feedback, and computerized food records may be easier to interpret by nutrition counselors. A number of computerized nutrient databases are available to assist patients and consumers in managing nutritional concerns.

  20. Policies and practices pertaining to the selection, qualification requirements, and training programs for nuclear-reactor operating personnel at the Oak Ridge National Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Culbert, W.H.

    1985-10-01

    This document describes the policies and practices of the Oak Ridge National Laboratory (ORNL) regarding the selection of and training requirements for reactor operating personnel at the Laboratory's nuclear-reactor facilities. The training programs, both for initial certification and for requalification, are described and provide the guidelines for ensuring that ORNL's research reactors are operated in a safe and reliable manner by qualified personnel. This document gives an overview of the reactor facilities and addresses the various qualifications, training, testing, and requalification requirements stipulated in DOE Order 5480.1A, Chapter VI (Safety of DOE-Owned Reactors); it is intended to be in compliancemore » with this DOE Order, as applicable to ORNL facilities. Included also are examples of the documentation maintained amenable for audit.« less

  1. F-Area Hazardous Waste Management Facility groundwater monitoring report, Third and fourth quarters 1995: Volume 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1996-03-01

    Groundwater at the F-Area Hazardous Waste Management Facility (HWMF) is monitored in compliance with applicable regulations. Monitoring results are compared to the South Carolina Department of Health and Environmental Control (SCDHEC) Groundwater Protection Standard (GWPS). Historically and currently, gross alpha, nitrates, nonvolatile beta, and tritium are among the primary constituents to exceed standards. Numerous other radionuclides and hazardous constituents also exceed the GWPS in the groundwater during the second half of 1995, notably cadmium, lead, radium-226, radium-228, strontium-90, and total alpha-emitting radium. The elevated constituents were found primarily in the water table (aquifer zone IIB{sub 2}), however, several other aquifermore » unit monitoring wells contained elevated levels of constituents. Water-level maps indicate that the groundwater flow rates and directions at the F-Area HWMF have remained relatively constant since the basins ceased to be active in 1988.« less

  2. Referenced-site environmental document for a Monitored Retrievable Storage facility: backup waste management option for handling 1800 MTU per year

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Silviera, D.J.; Aaberg, R.L.; Cushing, C.E.

    This environmental document includes a discussion of the purpose of a monitored retrievable storage facility, a description of two facility design concepts (sealed storage cask and field drywell), a description of three reference sites (arid, warm-wet, and cold-wet), and a discussion and comparison of the impacts associated with each of the six site/concept combinations. This analysis is based on a 15,000-MTU storage capacity and a throughput rate of up to 1800 MTU per year.

  3. A facility for training Space Station astronauts

    NASA Technical Reports Server (NTRS)

    Hajare, Ankur R.; Schmidt, James R.

    1992-01-01

    The Space Station Training Facility (SSTF) will be the primary facility for training the Space Station Freedom astronauts and the Space Station Control Center ground support personnel. Conceptually, the SSTF will consist of two parts: a Student Environment and an Author Environment. The Student Environment will contain trainers, instructor stations, computers and other equipment necessary for training. The Author Environment will contain the systems that will be used to manage, develop, integrate, test and verify, operate and maintain the equipment and software in the Student Environment.

  4. Sexual desire disorder in female healthcare personnel in Malaysia.

    PubMed

    Grewal, Gurdeep Singh; Gill, Jesjeet Singh; Sidi, Hatta; Gurpreet, Kaur; Jambunathan, Stephen Thevanathan; Suffee, Nusrat J

    2013-04-01

    The aim of this study was to determine the prevalence and risk factors for female sexual desire disorder (FSDD) among healthcare personnel at selected healthcare facilities in Malaysia. Two hundred and one female healthcare workers from three large tertiary hospitals were selected by stratified random sampling to participate in this cross-sectional study. Validated questionnaires were used to assess depression, anxiety, and sexual function in women and erectile dysfunction (ED) in their partners. The prevalence of FSDD was 18.9%. Women with low sexual desire were more likely to have higher educational attainment (OR = 3.06; 95% CI; 1.22-7.66), lower frequency of sexual intercourse (OR = 12.81; 95% CI; 4.43-37.83), two or more children (OR = 3.05; 95% CI; 1.02-9.09), duration of marriage of 20 years or more (OR = 2.62; 95% CI; 1.27-5.40), and a spouse with ED (OR = 2.86; 95% CI; 1.08-7.56). FSDD is common among female healthcare personnel in Malaysia, affecting nearly one in five women. The implication of low sexual desire is important in terms of contributing to a meaningful sexual relationship, and indirectly affects the quality of life of the healthcare personnel. Copyright © 2013 Wiley Publishing Asia Pty Ltd.

  5. CENTRAL FOOD STORE FACILITIES FOR COLLEGES AND UNIVERSITIES.

    ERIC Educational Resources Information Center

    BLOOMFIELD, BYRON C.

    INSPECTION OF A NUMBER OF INSTALLATIONS WAS ORIENTED TOWARD ARCHITECTURAL AND PLANNING QUESTIONS INVOLVING ECONOMICS AND SERVICES OF CENTRAL FOOD STORE FACILITIES. COMMENCING WITH THE PURCHASING PHILOSOPHY WHICH OVERVIEWS THE ORGANIZATION OF FOODS PURCHASING, SELECTION OF PERSONNEL, SPECIFICATIONS FOR PURCHASING, TECHNIQUES FOR PURCHASING, AND…

  6. Radiant Heat Test Facility (RHTF): User Test Planning Guide

    NASA Technical Reports Server (NTRS)

    DelPapa, Steven

    2011-01-01

    Test process, milestones and inputs are unknowns to first-time users of the RHTF. The User Test Planning Guide aids in establishing expectations for both NASA and non- NASA facility customers. The potential audience for this guide includes both internal and commercial spaceflight hardware/software developers. It is intended to assist their test engineering personnel in test planning and execution. Material covered includes a roadmap of the test process, roles and responsibilities of facility and user, major milestones, facility capabilities, and inputs required by the facility. Samples of deliverables, test article interfaces, and inputs necessary to define test scope, cost, and schedule are included as an appendix to the guide.

  7. 10 CFR Appendix E to Part 50 - Emergency Planning and Preparedness for Production and Utilization Facilities

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... organization shall be described. The communication steps to be taken to alert or activate emergency personnel... operations facility must include the following: (1) Space for members of an NRC site team and Federal, State, and local responders; (2) Additional space for conducting briefings with emergency response personnel...

  8. 10 CFR Appendix E to Part 50 - Emergency Planning and Preparedness for Production and Utilization Facilities

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... organization shall be described. The communication steps to be taken to alert or activate emergency personnel... operations facility must include the following: (1) Space for members of an NRC site team and Federal, State, and local responders; (2) Additional space for conducting briefings with emergency response personnel...

  9. 10 CFR Appendix E to Part 50 - Emergency Planning and Preparedness for Production and Utilization Facilities

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... organization shall be described. The communication steps to be taken to alert or activate emergency personnel... operations facility must include the following: (1) Space for members of an NRC site team and Federal, State, and local responders; (2) Additional space for conducting briefings with emergency response personnel...

  10. 33 CFR 154.525 - Monitoring devices.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Monitoring devices. 154.525... Monitoring devices. The COTP may require the facility to install monitoring devices if the installation of monitoring devices at the facility would significantly limit the size of a discharge of oil or hazardous...

  11. NASA personnel and facilities involved in Hurricane Katrina medical evacuation

    NASA Image and Video Library

    2005-09-02

    JSC2005-E-36144 (2 September 2005) --- NASA Johnson Space Center Aircraft Operations Hangar 990 at Ellington Field, Houston, has been used as a triage location this week for medical patients evacuated by air from New Orleans to pass through on their way to Houston-area medical facilities. Hundreds of patients have passed through the location so far, as the transfer operations, led by the Veterans Administration and supported by NASA and other agencies, continue.

  12. Plum Brook Reactor Facility Control Room during Facility Startup

    NASA Image and Video Library

    1961-02-21

    Operators test the National Aeronautics and Space Administration’s (NASA) Plum Brook Reactor Facility systems in the months leading up to its actual operation. The “Reactor On” signs are illuminated but the reactor core was not yet ready for chain reactions. Just a couple weeks after this photograph, Plum Brook Station held a media open house to unveil the 60-megawatt test reactor near Sandusky, Ohio. More than 60 members of the print media and radio and television news services met at the site to talk with community leaders and representatives from NASA and Atomic Energy Commission. The Plum Brook reactor went critical for the first time on the evening of June 14, 1961. It was not until April 1963 that the reactor reached its full potential of 60 megawatts. The reactor control room, located on the second floor of the facility, was run by licensed operators. The operators manually operated the shim rods which adjusted the chain reaction in the reactor core. The regulating rods could partially or completely shut down the reactor. The control room also housed remote area monitoring panels and other monitoring equipment that allowed operators to monitor radiation sensors located throughout the facility and to scram the reactor instantly if necessary. The color of the indicator lights corresponded with the elevation of the detectors in the various buildings. The reactor could also shut itself down automatically if the monitors detected any sudden irregularities.

  13. Atmospheric Radiation Measurement Program facilities newsletter, July 2000.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sisterson, D. L.; Holdridge, D. J., ed.

    2000-08-03

    For improved safety in and around the ARM SGP CART site, the ARM Program recently purchased and installed an aircraft detection radar system at the central facility near Lamont, Oklahoma. The new system will enhance safety measures already in place at the central facility. The SGP CART site, especially the central facility, houses several instruments employing laser technology. These instruments are designed to be eye-safe and are not a hazard to personnel at the site or pilots of low-flying aircraft over the site. However, some of the specialized equipment brought to the central facility by visiting scientists during scheduled intensivemore » observation periods (IOPs) might use higher-power laser beams that point skyward to make measurements of clouds or aerosols in the atmosphere. If these beams were to strike the eye of a person in an aircraft flying above the instrument, damage to the person's eyesight could result. During IOPs, CART site personnel have obtained Federal Aviation Administration (FAA) approval to temporarily close the airspace directly over the central facility and keep aircraft from flying into the path of the instrument's laser beam. Information about the blocked airspace is easily transmitted to commercial aircraft, but that does not guarantee that the airspace remains completely plane-free. For this reason, during IOPs in which non-eye-safe lasers were in use in the past, ARM technicians watched for low-flying aircraft in and around the airspace over the central facility. If the technicians spotted such an aircraft, they would manually trigger a safety shutter to block the laser beam's path skyward until the plane had cleared the area.« less

  14. 76 FR 34720 - Chemical Facility Anti-Terrorism Standards Personnel Surety Program

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-14

    ...; Date of birth; Place of birth; Gender; Citizenship; Passport information; Visa information; Alien... birth; and c. Citizenship or Gender. The Department will require that high-risk chemical facilities.... Aliases; b. Gender (for Non-U.S. persons); c. Place of birth; and d. DHS Redress Number. In lieu of...

  15. Environmental monitoring in a laboratory animal facility.

    PubMed

    Wellstood-Nuesse, S; Shields, R P

    1976-08-01

    A study was made of the microbial environmental status of an animal facility. Cultures were made of animal and surgical room floors; the germicidal effectiveness of the phenolic disinfectant-detergent employed in the facility was tested against standard test organisms as well as against other microorganisms isolated from the facility, and killing power of the disinfectant-detergent was evaluated during various steps of the usual cleaning procedures, ie, mops and mop bucket solutions were tested before, during, and after mopping a room. It was found that colony counts for animal rooms cleaned with a chlorhexidine disinfectant were much lower than those cleaned with a phenolic disinfectant. The phenolic disinfectant killed some organisms after 10 min exposure, but no others. Pseudomonads were the most resistant organisms. Contaminated mops and mop bucket solutions appeared responsible for the high counts on floors cleaned with the phenolic disinfectant. Guidelines for achievable levels of cleanliness were suggested.

  16. Air pollution effects field research facility: 3. UV-B exposure and monitoring system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McEvers, J.A.; Hileman, M.S.; Edwards, N.T.

    1993-03-01

    The Oak Ridge National Laboratory Outdoor UltraViolet-B (UV-B) Exposure and Monitoring Facility was developed in 1980 to provide well-controlled and -monitored exposure of specific terrestrial plant. species to elevated levels of ultraviolet (UV) radiation. The introduction of various anthropogenic agents into the earth`s stratosphere has resulted in a decrease in the volume of ozone (O{sub 3}) present here. The decrease in O{sub 3} has resulted in an increase in the level of UV radiation reaching thee earth`s surface. Of particular interest is the level of UV-B, because it has the most detrimental effect on living tissue. A thorough understanding ofmore » the effects of elevated levels of UV-B on living tissue is critical to the formulation of economic policy regarding production of such agents and alternative strategies. The UV region of interest is referred to as UV-B and corresponds to radiation with a wavelength of 290 to 320 nm. Design, operation, and performance of the automated generation, exposure, and monitoring system are described. The system has proved to be reliable and easy to maintain and operate, and it provides significant flexibility in exposure programs. The system software is described, and detailed listings are provided. The ability to expose plants to controlled set point percentages of UV-B above the ambient level was developed.« less

  17. DOE handbook: Guide to good practices for training and qualification of maintenance personnel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1996-03-01

    The purpose of this Handbook is to provide contractor training organizations with information that can be used to verify the adequacy of and/or modify existing maintenance training programs, or to develop new training programs. This guide, used in conjunction with facility-specific job analyses, provides a framework for training and qualification programs for maintenance personnel at DOE reactor and nonreactor nuclear facilities. Recommendations for qualification are made in four areas: education, experience, physical attributes, and training. The functional positions of maintenance mechanic, electrician, and instrumentation and control technician are covered by this guide. Sufficient common knowledge and skills were found tomore » include the three disciplines in one guide to good practices. Contents include: qualifications; on-the-job training; trainee evaluation; continuing training; training effectiveness evaluation; and program records. Appendices are included which relate to: administrative training; industrial safety training; fundamentals training; tools and equipment training; facility systems and component knowledge training; facility systems and component skills training; and specialized skills training.« less

  18. Lessons Learned from Radioactive Waste Storage and Disposal Facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Esh, David W.; Bradford, Anna H.

    2008-01-15

    The safety of radioactive waste disposal facilities and the decommissioning of complex sites may be predicated on the performance of engineered and natural barriers. For assessing the safety of a waste disposal facility or a decommissioned site, a performance assessment or similar analysis is often completed. The analysis is typically based on a site conceptual model that is developed from site characterization information, observations, and, in many cases, expert judgment. Because waste disposal facilities are sited, constructed, monitored, and maintained, a fair amount of data has been generated at a variety of sites in a variety of natural systems. Thismore » paper provides select examples of lessons learned from the observations developed from the monitoring of various radioactive waste facilities (storage and disposal), and discusses the implications for modeling of future waste disposal facilities that are yet to be constructed or for the development of dose assessments for the release of decommissioning sites. Monitoring has been and continues to be performed at a variety of different facilities for the disposal of radioactive waste. These include facilities for the disposal of commercial low-level waste (LLW), reprocessing wastes, and uranium mill tailings. Many of the lessons learned and problems encountered provide a unique opportunity to improve future designs of waste disposal facilities, to improve dose modeling for decommissioning sites, and to be proactive in identifying future problems. Typically, an initial conceptual model was developed and the siting and design of the disposal facility was based on the conceptual model. After facility construction and operation, monitoring data was collected and evaluated. In many cases the monitoring data did not comport with the original site conceptual model, leading to additional investigation and changes to the site conceptual model and modifications to the design of the facility. The following cases are

  19. 40 CFR 35.935-17 - Training facility.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... STATE AND LOCAL ASSISTANCE Grants for Construction of Treatment Works-Clean Water Act § 35.935-17 Training facility. If assistance has been provided for the construction of a treatment works required to train and upgrade waste treatment personnel under §§ 35.930-1(b) and 35.920-3(e), the grantee must...

  20. 40 CFR 35.935-17 - Training facility.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... STATE AND LOCAL ASSISTANCE Grants for Construction of Treatment Works-Clean Water Act § 35.935-17 Training facility. If assistance has been provided for the construction of a treatment works required to train and upgrade waste treatment personnel under §§ 35.930-1(b) and 35.920-3(e), the grantee must...

  1. Shielding and Radiation Protection in Ion Beam Therapy Facilities

    NASA Astrophysics Data System (ADS)

    Wroe, Andrew J.; Rightnar, Steven

    Radiation protection is a key aspect of any radiotherapy (RT) department and is made even more complex in ion beam therapy (IBT) by the large facility size, secondary particle spectra and intricate installation of these centers. In IBT, large and complex radiation producing devices are used and made available to the public for treatment. It is thus the responsibility of the facility to put in place measures to protect not only the patient but also the general public, occupationally and nonoccupationally exposed personnel working within the facility, and electronics installed within the department to ensure maximum safety while delivering maximum up-time.

  2. Wearable technologies for soldier first responder assessment and remote monitoring (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Lee, Stephen

    2017-05-01

    Embedded combat medical personnel require accurate and timely biometric data to ensure appropriate life saving measures. Injured warfighter's operating in remote environments require both assessment and monitoring often while still engaged with enemy forces. Small wearable devices that can be placed on injured personnel capable of collecting essential biometric data, including the capacity to remotely deliver collected data in real-time, would allow additional medical monitoring and triage that will greatly help the medic in the battlefield. These new capabilities will provide a force multiplier through remote assessment, increased survivability, and in freeing engaged warfighter's from direct monitoring thus improving combat effectiveness and increasing situational awareness. Key questions around what information does the medic require and how effective it can be relayed to support personnel are at their early stages of development. A low power biometric wearable device capable of reliable electrocardiogram (EKG) rhythm, temperature, pulse, and other vital data collection which can provide real-time remote monitoring are in development for the Soldier.

  3. 40 CFR 437.4 - Monitoring requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    .... (a) Permit compliance monitoring is required for each regulated parameter. (b) Any CWT facility that... subpart. (3) When a CWT facility treats any waste receipt that contains cyanide at a concentration higher than 136 mg/L, the CWT facility must monitor for cyanide after cyanide treatment and before dilution...

  4. 40 CFR 437.4 - Monitoring requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    .... (a) Permit compliance monitoring is required for each regulated parameter. (b) Any CWT facility that... subpart. (3) When a CWT facility treats any waste receipt that contains cyanide at a concentration higher than 136 mg/L, the CWT facility must monitor for cyanide after cyanide treatment and before dilution...

  5. 40 CFR 437.4 - Monitoring requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    .... (a) Permit compliance monitoring is required for each regulated parameter. (b) Any CWT facility that... subpart. (3) When a CWT facility treats any waste receipt that contains cyanide at a concentration higher than 136 mg/L, the CWT facility must monitor for cyanide after cyanide treatment and before dilution...

  6. Advances in the Remote Monitoring of Balloon Flights

    NASA Astrophysics Data System (ADS)

    Breeding, S.

    At the National Scientific Balloon Facility (NSBF), we must staff the Long Duration Balloon (LDB) control center 24 hours a day during LDB flights. This requires three daily shifts of two operators (balloon control and tdrss scheduling). In addition to this we also have one engineer on-call as LDB Lead to resolve technical issues and one manager on-call for flight management. These on-call periods are typically 48 to 72 hours in length. In the past the on-call staff had to travel to the LDB control center in order to monitor the status of a flight in any detail. This becomes problematic as flight durations push out beyond 20 to 30 day lengths, as these staff members are not available for business travel during these periods. This paper describes recent advances which allow for the remote monitoring of scientific balloon flight ground station computer displays. This allows balloon flight managers and lead engineers to check flight status and performance from any location with a network or telephone connection. This capability frees key personnel from the NSBF base during flights. It also allows other interested parties to check on the flight status at their convenience.

  7. Environmental monitoring of the orbiter payload bay and Orbiter Processing Facilities

    NASA Technical Reports Server (NTRS)

    Bartelson, D. W.; Johnson, A. M.

    1985-01-01

    Contamination control in the Orbiter Processing Facility (OPF) is studied. The clean level required in the OPF is generally clean, which means no residue, dirt, debris, or other extraneous contamination; various methods of maintaining this level of cleanliness are described. The monitoring and controlling of the temperature, relative humidity, and air quality in the OPF are examined. Additional modifications to the OPF to improve contamination control are discussed. The methods used to maintain the payload changeout room at a level of visually clean, no particulates are to be detected by the unaided eye, are described. The payload bay (PLB) must sustain the cleanliness level required for the specific Orbiter's mission; the three levels of clean are defined as: (1) standard, (2) sensitive, and (3) high sensitive. The cleaning and inspection verification required to achieve the desired cleanliness level on a variety of PLB surface types are examined.

  8. Anthropometrics, body composition, and aerobic fitness in Norwegian home guard personnel.

    PubMed

    Aandstad, Anders; Hageberg, Rune; Holme, Ingar M; Anderssen, Sigmund A

    2014-11-01

    The Norwegian Home Guard (HG) consists of soldiers and officers who primarily live a civilian life but are typically called in for military training a few days per year. Although full-time soldiers and officers are monitored annually on physical fitness, no such assessments are performed on regular HG personnel. Data on physical fitness of similar forces from other nations are also scarce. Thus, the main aim of this study was to collect reference data on physical fitness in HG personnel. A total of 799 male soldiers and officers from the regular and the rapid reaction HG force participated in this study. Between 13 and 19% of the subjects were obese, according to measured body mass index, waist circumference and estimations of body fat. The mean (95% confidence interval) estimated peak oxygen uptake from the 20-m shuttle run test was 50.1 (49.7-50.6) mL·kg·minute. Personnel from the rapid reaction force had a more favorable body composition compared with the regular HG personnel, whereas no differences were found for peak oxygen uptake. The physical demands on HG personnel are not well defined, but we believe that the majority of Norwegian HG soldiers and officers have a sufficient aerobic fitness level to fulfill their planned HG tasks. The gathered data can be used by military leaders to review the ability of the HG to perform expected military tasks, to serve as a future reference material for secular changes in HG fitness level, and for comparison purposes among similar international reserve forces.

  9. Vibration and Acoustic Test Facility (VATF): User Test Planning Guide

    NASA Technical Reports Server (NTRS)

    Fantasia, Peter M.

    2011-01-01

    Test process, milestones and inputs are unknowns to first-time users of the VATF. The User Test Planning Guide aids in establishing expectations for both NASA and non-NASA facility customers. The potential audience for this guide includes both internal and commercial spaceflight hardware/software developers. It is intended to assist their test engineering personnel in test planning and execution. Material covered includes a roadmap of the test process, roles and responsibilities of facility and user, major milestones, facility capabilities, and inputs required by the facility. Samples of deliverables, test article interfaces, and inputs necessary to define test scope, cost, and schedule are included as an appendix to the guide.

  10. 40 CFR 792.29 - Personnel.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 31 2010-07-01 2010-07-01 true Personnel. 792.29 Section 792.29 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT (CONTINUED) GOOD LABORATORY PRACTICE STANDARDS Organization and Personnel § 792.29 Personnel. (a) Each individual...

  11. 40 CFR 160.29 - Personnel.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Personnel. 160.29 Section 160.29 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PESTICIDE PROGRAMS GOOD LABORATORY PRACTICE STANDARDS Organization and Personnel § 160.29 Personnel. (a) Each individual engaged in the...

  12. Models of Personnel Needs Assessment.

    ERIC Educational Resources Information Center

    Mattson, Beverly

    This report presents samples of models and strategies for determining professional development needs of special education personnel. The following areas are covered: definitions of needs and the needs assessment process; personnel needs assessment regulations under the Comprehensive System of Personnel Development, the Individuals with…

  13. 10 CFR 1016.25 - Protective personnel.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Protective personnel. 1016.25 Section 1016.25 Energy DEPARTMENT OF ENERGY (GENERAL PROVISIONS) SAFEGUARDING OF RESTRICTED DATA Physical Security § 1016.25 Protective personnel. Whenever protective personnel are required by § 1016.23, such protective personnel...

  14. 10 CFR 1016.25 - Protective personnel.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 4 2011-01-01 2011-01-01 false Protective personnel. 1016.25 Section 1016.25 Energy DEPARTMENT OF ENERGY (GENERAL PROVISIONS) SAFEGUARDING OF RESTRICTED DATA Physical Security § 1016.25 Protective personnel. Whenever protective personnel are required by § 1016.23, such protective personnel...

  15. Acceptable Practices in Maintaining Personnel Files.

    ERIC Educational Resources Information Center

    American Association of School Personnel Administrators, Seven Hills, OH.

    Determining acceptable practices in maintaining personnel files is a pertinent issue for school personnel administrators today. Recognizing this, the Georgia Association of School Personnel Administrators accepted the study of this topic as a committee assignment from the American Association of School Personnel Administrators. A survey instrument…

  16. 46 CFR 310.5 - Personnel.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... for State, Territorial or Regional Maritime Academies and Colleges § 310.5 Personnel. (a) Selection... same criteria used in the employment of such personnel in State-supported colleges and universities... watch aboard at all times. (c) Insignia for officers and other School personnel. The State may furnish...

  17. RADIATION FACILITY FOR NUCLEAR REACTORS

    DOEpatents

    Currier, E.L. Jr.; Nicklas, J.H.

    1961-12-12

    A radiation facility is designed for irradiating samples in close proximity to the core of a nuclear reactor. The facility comprises essentially a tubular member extending through the biological shield of the reactor and containing a manipulatable rod having the sample carrier at its inner end, the carrier being longitudinally movable from a position in close proximity to the reactor core to a position between the inner and outer faces of the shield. Shield plugs are provided within the tubular member to prevent direct radiation from the core emanating therethrough. In this device, samples may be inserted or removed during normal operation of the reactor without exposing personnel to direct radiation from the reactor core. A storage chamber is also provided within the radiation facility to contain an irradiated sample during the period of time required to reduce the radioactivity enough to permit removal of the sample for external handling. (AEC)

  18. Training Personnel for Special Needs

    ERIC Educational Resources Information Center

    Tomlinson, Robert M.; Fabac, John N.

    1978-01-01

    Attempting to develop a framework for personnel development programs which train personnel to work with individuals who have special needs, this article discusses the inadequacies of traditional grouping patterns in education, then identifies those special skills needed by school personnel in addition to the skills taught in traditional teacher…

  19. Navy-Wide Personnel Survey 1993: Statistical Tables for Enlisted Personnel

    DTIC Science & Technology

    1994-04-01

    WIDE PERSONNEL SURVEY, ENLISTED NPRDC SAN DIEGO. Q92 HOW OFTEN EAT 5 SERVINGS VEGGIES BY Q21 PAYGRADE Q21 PAYGRADE ROW E2-E3 E4-E6 E7-E9 TOTAL Q92 142...OBSERVATIONS: 61 1993 NAVY-WIDE PERSONNEL SURVEY, ENLISTED NPRDC SAN DIEGO Q92 HOW OFTEN EAT 5 SERVINGS VEGGIES BY Q2 GENDER Q2 ROW MALE FEMALE TOTAL

  20. Grande Ronde Endemic Spring Chinook Salmon Supplementation Program: Facility Operation and Maintenance and Monitoring and Evaluation, 1999 Annual Report.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boe, Stephen J.; Lofy, Peter T.

    2002-11-01

    This is the second annual report of a multi-year, multi-agency project to restore spring chinook salmon populations in the Grande Ronde River Basin (Grande Ronde Endemic Chinook Salmon Program--GRESCP). The Confederated Tribes of the Umatilla Indian Reservation (CTUIR) operates adult collection and juvenile acclimation facilities on Catherine Creek and the upper Grande Ronde River for Snake River spring chinook salmon. These two streams have historically supported populations that provided significant tribal and non-tribal fisheries. Supplementation using conventional and captive broodstock techniques is being used to increase natural production and restore fisheries in these two streams. Statement of Work Objectives formore » 1999: (1) Participate in development and continued implementation of the comprehensive multi year operations plan for the Grande Ronde Endemic Supplementation Program. (2) Ensure proper construction and trial operation of semi-permanent adult and juvenile facilities for use in 2000. (3) Monitor adult endemic spring chinook salmon populations and collect broodstock. (4) Plan detailed Monitoring and Evaluation for future years. (5) Monitor population abundance and characteristics and local environmental factors that may influence abundance and run timing of Grande Ronde River spring chinook populations. (6) Participate in Monitoring and Evaluation of the captive brood component of the Program to assure this component is contributing to the Program. (7) Participate in data collection for incidentally-caught bull trout and summer steelhead and planning for recovery of summer steelhead populations. (8) Document accomplishments and needs to permitters, comanagers, and funding agencies. (9) Communicate project results to the scientific community.« less

  1. Design and Testing of a Solid-Liquid Interface Monitor for High-Level Waste Tanks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McDaniel, D.; Awwad, A.; Roelant, D.

    2008-07-01

    A high-level waste (HLW) monitor has been designed, fabricated and tested at full-scale for deployment inside a Hanford tank. The Solid-Liquid Interface Monitor (SLIM) integrates a commercial sonar system with a mechanical deployment system for deploying into an underground waste tank. The system has undergone several design modifications based upon changing requirements at Hanford. We will present the various designs of the monitor from first to last and will present performance data from the various prototype systems. We will also present modeling of stresses in the enclosure under 85 mph wind loading. The system must be able to function atmore » winds up to 15 mph and must withstand a maximum loading of 85 mph. There will be several examples presented of engineering tradeoffs made as FIU analyzed new requirements and modified the design to accommodate. We will present our current plans for installing into the Cold Test Facility at Hanford and into a double-shelled tank at Hanford. Finally, we will present our vision for how this technology can be used at Hanford and Savannah River Site to improve the filling and emptying of high-level waste tanks. In conclusion: 1. The manually operated first-generation SLIM is a viable option on tanks where personnel are allowed to work on top of the tank. 2. The remote controlled second-generation SLIM can be utilized on tanks where personnel access is limited. 3. The totally enclosed fourth-generation SLIM, when the design is finalized, can be used when the possibility exists for wind dispersion of any HLW that maybe on the system. 4. The profiling sonar can be used effectively for real-time monitoring of the solid-liquid interface over a large area. (authors)« less

  2. 21 CFR 58.29 - Personnel.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Personnel. 58.29 Section 58.29 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL GOOD LABORATORY PRACTICE FOR NONCLINICAL LABORATORY STUDIES Organization and Personnel § 58.29 Personnel. (a) Each individual engaged in...

  3. Personnel Management: Two Year Colleges.

    ERIC Educational Resources Information Center

    Ohio Board of Regents, Columbus. Management Improvement Program.

    This document is one of five manuals designed to improve management practices in Ohio two-year colleges. A chapter on organizing for personnel management discusses basic personnel functions, roles and responsibilities of administrators, and the need for a central statewide office of personnel affairs. A chapter on planning, policies, and…

  4. 5 CFR 772.102 - Interim personnel actions.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 5 Administrative Personnel 2 2011-01-01 2011-01-01 false Interim personnel actions. 772.102 Section 772.102 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT (CONTINUED) CIVIL SERVICE REGULATIONS (CONTINUED) INTERIM RELIEF General § 772.102 Interim personnel actions. When an employee or...

  5. 5 CFR 772.102 - Interim personnel actions.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 5 Administrative Personnel 2 2010-01-01 2010-01-01 false Interim personnel actions. 772.102 Section 772.102 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT (CONTINUED) CIVIL SERVICE REGULATIONS (CONTINUED) INTERIM RELIEF General § 772.102 Interim personnel actions. When an employee or...

  6. Trace Gas Monitoring

    NASA Technical Reports Server (NTRS)

    1976-01-01

    Space technology is contributing to air pollution control primarily through improved detectors and analysis methods. Miniaturized mass spectrometer is under development to monitor vinyl chloride and other hydrocarbon contaminants in an airborne laboratory. Miniaturized mass spectrometer can be used to protect personnel in naval and medical operations as well as aboard aircraft.

  7. Improving primary health care facility performance in Ghana: efficiency analysis and fiscal space implications.

    PubMed

    Novignon, Jacob; Nonvignon, Justice

    2017-06-12

    Health centers in Ghana play an important role in health care delivery especially in deprived communities. They usually serve as the first line of service and meet basic health care needs. Unfortunately, these facilities are faced with inadequate resources. While health policy makers seek to increase resources committed to primary healthcare, it is important to understand the nature of inefficiencies that exist in these facilities. Therefore, the objectives of this study are threefold; (i) estimate efficiency among primary health facilities (health centers), (ii) examine the potential fiscal space from improved efficiency and (iii) investigate the efficiency disparities in public and private facilities. Data was from the 2015 Access Bottlenecks, Cost and Equity (ABCE) project conducted by the Institute for Health Metrics and Evaluation. The Stochastic Frontier Analysis (SFA) was used to estimate efficiency of health facilities. Efficiency scores were then used to compute potential savings from improved efficiency. Outpatient visits was used as output while number of personnel, hospital beds, expenditure on other capital items and administration were used as inputs. Disparities in efficiency between public and private facilities was estimated using the Nopo matching decomposition procedure. Average efficiency score across all health centers included in the sample was estimated to be 0.51. Also, average efficiency was estimated to be about 0.65 and 0.50 for private and public facilities, respectively. Significant disparities in efficiency were identified across the various administrative regions. With regards to potential fiscal space, we found that, on average, facilities could save about GH₵11,450.70 (US$7633.80) if efficiency was improved. We also found that fiscal space from efficiency gains varies across rural/urban as well as private/public facilities, if best practices are followed. The matching decomposition showed an efficiency gap of 0.29 between private

  8. Inactive Health Personnel Project: Final Report.

    ERIC Educational Resources Information Center

    Schiavone, Geraldine R. S.

    The Inactive Health Personnel Project, conducted by the New Jersey Department of Health in 1967, had as objectives to increase the supply of health manpower by locating health personnel and promoting their active employment; to develop the details of health personnel needs by category of personnel and geographic area; and to assist in the return…

  9. Benefits of adopting good radiation practices in reducing the whole body radiation dose to the nuclear medicine personnel during (18)F-fluorodeoxyglucose positron emission tomography/computed tomography imaging.

    PubMed

    Verma, Shashwat; Kheruka, Subhash Chand; Maurya, Anil Kumar; Kumar, Narvesh; Gambhir, Sanjay; Kumari, Sarita

    2016-01-01

    Positron emission tomography has been established as an important imaging modality in the management of patients, especially in oncology. The higher gamma radiation energy of positron-emitting isotopes poses an additional radiation safety problem. Those working with this modality may likely to receive higher whole body doses than those working only in conventional nuclear medicine. The radiation exposure to the personnel occurs in dispensing the dose, administration of activity, patient positioning, and while removing the intravenous (i.v.) cannula. The estimation of radiation dose to Nuclear Medicine Physician (NMP) involved during administration of activity to the patient and technical staff assisting in these procedures in a positron emission tomography/computed tomography (PET/CT) facility was carried out. An i.v access was secured for the patient by putting the cannula and blood sugar was monitored. The activity was then dispensed and measured in the dose calibrator and administered to the patient by NMP. Personnel doses received by NMP and technical staff were measured using electronic pocket dosimeter. The radiation exposure levels at various working locations were assessed with the help of gamma survey meter. The radiation level at working distance while administering the radioactivity was found to be 106-170 μSv/h with a mean value of 126.5 ± 14.88 μSv/h which was reduced to 4.2-14.2 μSv/h with a mean value of 7.16 ± 2.29 μSv/h with introduction of L-bench for administration of radioactivity. This shows a mean exposure level reduction of 94.45 ± 1.03%. The radiation level at working distance, while removing the i.v. cannula postscanning was found to be 25-70 μSv/h with a mean value of 37.4 ± 13.16 μSv/h which was reduced to 1.0-5.0 μSv/h with a mean value of 2.77 ± 1.3 μSv/h with introduction of L-bench for removal of i.v cannula. This shows a mean exposure level reduction of 92.85 ± 1.78%. This study shows that good radiation practices are

  10. Implementation of the MPC and A Operations Monitoring (MOM) System at IRT-T FSRE Nuclear Power Institute (NPI)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sitdikov,I.; Zenkov, A.; Tsibulnikov, Y.

    The Material Protection, Control and Accounting (MPC&A) Program has been working since 1994 with nuclear sites in Russia to upgrade the physical protection (PP) and material control and accounting (MC&A) functions at facilities containing weapons usable nuclear material. In early 2001, the MPC&A program initiated the MPC&A Operations Monitoring (MOM) Project to monitor facilities where MPC&A upgrades have been installed to provide increased confidence that personnel are present and vigilant, provide confidence that security procedures are being properly performed and provide additional assurance that nuclear materials have not been stolen. The MOM project began as a pilot project at themore » Moscow State Engineering Physics Institute (MEPhI) and a MOM system was successfully installed in October 2001. Following the success of the MEPhI pilot project, the MPC&A Program expanded the installation of MOM systems to several other Russian facilities, including the Nuclear Physics Institute (NPI) in Tomsk. The MOM system was made operational at NPI in October 2004. This paper is focused on the experience gained from operation of this system and the objectives of the MOM system. The paper also describes how the MOM system is used at NPI and, in particular, how the data is analyzed. Finally, potential expansion of the MOM system at NPI is described.« less

  11. Sanford Underground Research Facility - The United State's Deep Underground Research Facility

    NASA Astrophysics Data System (ADS)

    Vardiman, D.

    2012-12-01

    The 2.5 km deep Sanford Underground Research Facility (SURF) is managed by the South Dakota Science and Technology Authority (SDSTA) at the former Homestake Mine site in Lead, South Dakota. The US Department of Energy currently supports the development of the facility using a phased approach for underground deployment of experiments as they obtain an advanced design stage. The geology of the Sanford Laboratory site has been studied during the 125 years of operations at the Homestake Mine and more recently as part of the preliminary geotechnical site investigations for the NSF's Deep Underground Science and Engineering Laboratory project. The overall geology at DUSEL is a well-defined stratigraphic sequence of schist and phyllites. The three major Proterozoic units encountered in the underground consist of interbedded schist, metasediments, and amphibolite schist which are crosscut by Tertiary rhyolite dikes. Preliminary geotechnical site investigations included drift mapping, borehole drilling, borehole televiewing, in-situ stress analysis, laboratory analysis of core, mapping and laser scanning of new excavations, modeling and analysis of all geotechnical information. The investigation was focused upon the determination if the proposed site rock mass could support the world's largest (66 meter diameter) deep underground excavation. While the DUSEL project has subsequently been significantly modified, these data are still available to provide a baseline of the ground conditions which may be judiciously extrapolated throughout the entire Proterozoic rock assemblage for future excavations. Recommendations for facility instrumentation and monitoring were included in the preliminary design of the DUSEL project design and include; single and multiple point extensometers, tape extensometers and convergence measurements (pins), load cells and pressure cells, smart cables, inclinometers/Tiltmeters, Piezometers, thermistors, seismographs and accelerometers, scanners (laser

  12. The development of remote wireless radiation dose monitoring system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Jin-woo; Chonbuk National University, Jeonjoo-Si; Jeong, Kyu-hwan

    Internet of things (IoT) technology has recently shown a large flow of IT trends in human life. In particular, our lives are now becoming integrated with a lot of items around the 'smart-phone' with IoT, including Bluetooth, Near Field Communication (NFC), Beacons, WiFi, and Global Positioning System (GPS). Our project focuses on the interconnection of radiation dosimetry and IoT technology. The radiation workers at a nuclear facility should hold personal dosimeters such as a Thermo-Luminescence Dosimeter (TLD), an Optically Stimulated Luminescence Dosimeter (OSL), pocket ionization chamber dosimeters, an Electronic Personal Dosimeter (EPD), or an alarm dosimeter on their body. Somemore » of them have functions that generate audible or visible alarms to radiation workers in a real working area. However, such devices used in radiation fields these days have no functions for communicating with other areas or the responsible personnel in real time. In particular, when conducting a particular task in a high dose area, or a number of repair works within a radiation field, radiation dose monitoring is important for the health of the workers and the work efficiency. Our project aims at the development of a remote wireless radiation dose monitoring system (RWRD) that can be used to monitor the radiation dose in a nuclear facility for radiation workers and a radiation protection program In this project, a radiation dosimeter is the detection device for personal radiation dose, a smart phone is the mobile wireless communication tool, and, Beacon is the wireless starter for the detection, communication, and position of the worker using BLE (Bluetooth Low Energy). In this report, we report the design of the RWRD and a demonstration case in a real radiation field. (authors)« less

  13. 7 CFR 1942.18 - Community facilities-Planning, bidding, contracting, constructing.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... which will contribute to the preservation and enhancement of sites, structures, and objects of...-96-1, “Guidelines for Construction and Equipment of Hospital and Medical Facilities,” 1987 Edition.... Owners may accomplish construction by using their own personnel and equipment provided the owners possess...

  14. Child responsible personnel in adult mental health services.

    PubMed

    Lauritzen, Camilla; Reedtz, Charlotte

    2016-01-01

    Children who have parents with mental health problems are a vulnerable group. Intervening early to support parents with a mental illness can contribute to improve outcomes for children. Rigging the adult mental health system in such a manner that child responsible personnel are designated in wards is a strategy to systematically address the needs of families. It has since 2010 been mandatory for Norwegian hospitals to appoint such personnel in all hospital wards. The current study aimed to investigate the appointment of child responsible personnel in the adult mental health services in a regional hospital with local clinics. Additionally, to describe the characteristics of child responsible staff in terms of gender and educational background, their competence, clinical practice and knowledge about parental mental illness. A final aim was to study whether or not the clinics had established collaboration with other services concerning follow-up for the children of parents with mental illness. Participants in this study are the staff at psychiatric clinics in a large university hospital in Norway. Practitioners were asked to answer a questionnaire prior to the initial process of implementing the new legislation in 2010 (N = 219). After a three-year period of implementing routines to adopt the new law in the clinic, the same survey was sent out to the staff in 2013 (N = 185) to monitor if changes were taking place. To study if the changes were sustained within the clinics, we conducted a two-year follow up in 2015 (N = 108). The results indicated that the systematic work to change clinical practice in the participating hospital had made a difference. Routines to follow up children's patients after the new legislation had to some extent been implemented. The child responsible personnel had more knowledge and awareness about the consequences of parental mental illness for children. The results of this study suggested that the systems change of establishing child

  15. Thermal-work strain in law enforcement personnel during chemical, biological, radiological, and nuclear (CBRN) training

    PubMed Central

    Yokota, M; Karis, A J; Tharion, W J

    2014-01-01

    Background: Thermal safety standards for the use of chemical, biological, radiological, and nuclear (CBRN) ensembles have been established for various US occupations, but not for law enforcement personnel. Objectives: We examined thermal strain levels of 30 male US law enforcement personnel who participated in CBRN field training in Arizona, Florida, and Massachusetts. Methods: Physiological responses were examined using unobtrusive heart rate (HR) monitors and a simple thermoregulatory model to predict core temperature (Tc) using HR and environment. Results: Thermal strain levels varied by environments, activity levels, and type of CBRN ensemble. Arizona and Florida volunteers working in hot-dry and hot-humid environment indicated high heat strain (predicted max Tc>38.5°C). The cool environment of Massachusetts reduced thermal strain although thermal strains were occasionally moderate. Conclusions: The non-invasive method of using physiological monitoring and thermoregulatory modeling could improve law enforcement mission to reduce the risk of heat illness or injury. PMID:24999847

  16. Physics Simulation Software for Autonomous Propellant Loading and Gas House Autonomous System Monitoring

    NASA Technical Reports Server (NTRS)

    Regalado Reyes, Bjorn Constant

    2015-01-01

    1. Kennedy Space Center (KSC) is developing a mobile launching system with autonomous propellant loading capabilities for liquid-fueled rockets. An autonomous system will be responsible for monitoring and controlling the storage, loading and transferring of cryogenic propellants. The Physics Simulation Software will reproduce the sensor data seen during the delivery of cryogenic fluids including valve positions, pressures, temperatures and flow rates. The simulator will provide insight into the functionality of the propellant systems and demonstrate the effects of potential faults. This will provide verification of the communications protocols and the autonomous system control. 2. The High Pressure Gas Facility (HPGF) stores and distributes hydrogen, nitrogen, helium and high pressure air. The hydrogen and nitrogen are stored in cryogenic liquid state. The cryogenic fluids pose several hazards to operators and the storage and transfer equipment. Constant monitoring of pressures, temperatures and flow rates are required in order to maintain the safety of personnel and equipment during the handling and storage of these commodities. The Gas House Autonomous System Monitoring software will be responsible for constantly observing and recording sensor data, identifying and predicting faults and relaying hazard and operational information to the operators.

  17. Biomedical Monitoring and Countermeasures Facility

    NASA Technical Reports Server (NTRS)

    Stewart, Donald F.

    1992-01-01

    The Space Station Freedom Program (SSFP) represents the transition within the US Space program from the 'heroic' era of space flight (characterized most vividly by the Mercury and Apollo programs) to an epoch characterized by routine access to the space environment. In this new era, the unique characteristics of the microgravity environment will enable new types of research activities, primarily in the life sciences, materials science, and biotechnology fields. In addition to its role as a'microgravity science laboratory,' Space Station Freedom (SSF) constitutes the operational platform on which the knowledge and skills needed to continue our exploration of space will be acquired. In the area of spacecraft operations, these skills include the ability to assemble, operate, and maintain large structures in space. In the area of crew operations, the potentially harmful effects of extended exposure to microgravity must be understood in order to keep the crew mission capable. To achieve this goal, the complex process of physiological deconditioning must be monitored, and countermeasures utilized as needed to keep the individual crew members within acceptable physiological limits. The countermeasures program under development for the SSF Program is titled the Biomedical Monitoring and Countermeasures (BMAC) program. As implied by the name, this activity has two primary products, a biomedical monitoring element and a countermeasures development effort. The program is a critical path element in the overall SSF Program, and should be considered an essential element of operations on board the space station. It is readily apparent that the capability to both protect and optimize the health and performance of the human operators on board SSF will be a critical element in the overall success of the SSFP. Previous experience within the Russian space program has demonstrated that the time required for countermeasures on extended missions can become a monumental operational burden

  18. Compliance with Antimalarial Chemoprophylaxis Recommendations for Wounded United States Military Personnel Admitted to a Military Treatment Facility

    PubMed Central

    Rini, Elizabeth A.; Weintrob, Amy C.; Tribble, David R.; Lloyd, Bradley A.; Warkentien, Tyler E.; Shaikh, Faraz; Li, Ping; Aggarwal, Deepak; Carson, M. Leigh; Murray, Clinton K.

    2014-01-01

    Malaria chemoprophylaxis is used as a preventive measure in military personnel deployed to malaria-endemic countries. However, limited information is available on compliance with chemoprophylaxis among trauma patients during hospitalization and after discharge. Therefore, we assessed antimalarial primary chemoprophylaxis and presumptive antirelapse therapy (primaquine) compliance among wounded United States military personnel after medical evacuation from Afghanistan (June 2009–August 2011) to Landstuhl Regional Medical Center in Landstuhl, Germany, and then to three U.S. military hospitals. Among admissions at Landstuhl Regional Medical Center, 74% of 2,540 patients were prescribed primary chemoprophylaxis and < 1% were prescribed primaquine. After transfer of 1,331 patients to U.S. hospitals, 93% received primary chemoprophylaxis and 33% received primaquine. Of 751 trauma patients with available post-admission data, 42% received primary chemoprophylaxis for four weeks, 33% received primaquine for 14 days, and 17% received both. These antimalarial chemoprophylaxis prescription rates suggest that improved protocols to continue malaria chemoprophylaxis in accordance with force protection guidelines are needed. PMID:24732457

  19. M-Area and Metallurgical Laboratory Hazardous Waste Management Facilities groundwater monitoring and corrective-action report (U). Third and fourth quarters 1996, Vol. I

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1997-03-01

    This report describes the groundwater monitoring and corrective-action program at the M-Area Hazardous Waste Management Facility (HWMF) and the Metallurgical Laboratory (Met Lab) HWMF at the Savannah River Site (SRS) during 1996.

  20. Energy Systems Integration Facility Control Room | Energy Systems

    Science.gov Websites

    Integration Facility | NREL Energy Systems Integration Facility Control Room Energy Systems Integration Facility Control Room The Energy Systems Integration Facility control room allows system engineers as the monitoring point for the facility's integrated safety and control systems. Photo of employees

  1. Embracing Safe Ground Test Facility Operations and Maintenance

    NASA Technical Reports Server (NTRS)

    Dunn, Steven C.; Green, Donald R.

    2010-01-01

    Conducting integrated operations and maintenance in wind tunnel ground test facilities requires a balance of meeting due dates, efficient operation, responsiveness to the test customer, data quality, effective maintenance (relating to readiness and reliability), and personnel and facility safety. Safety is non-negotiable, so the balance must be an "and" with other requirements and needs. Pressure to deliver services faster at increasing levels of quality in under-maintained facilities is typical. A challenge for management is to balance the "need for speed" with safety and quality. It s especially important to communicate this balance across the organization - workers, with a desire to perform, can be tempted to cut corners on defined processes to increase speed. Having a lean staff can extend the time required for pre-test preparations, so providing a safe work environment for facility personnel and providing good stewardship for expensive National capabilities can be put at risk by one well-intending person using at-risk behavior. This paper documents a specific, though typical, operational environment and cites management and worker safety initiatives and tools used to provide a safe work environment. Results are presented and clearly show that the work environment is a relatively safe one, though still not good enough to keep from preventing injury. So, the journey to a zero injury work environment - both in measured reality and in the minds of each employee - continues. The intent of this paper is to provide a benchmark for others with operational environments and stimulate additional sharing and discussion on having and keeping a safe work environment.

  2. A Multidisciplinary Paradigm and Approach to Protecting Human Health and the Environment, Society, and Stakeholders at Nuclear Facilities - 12244

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Burger, Joanna; Environmental and Occupational Health Sciences Institute, Piscataway, NJ; Gochfeld, Michael

    2012-07-01

    As the Department of Energy (DOE) continues to remediate its lands, and to consider moving toward long-term stewardship and the development of energy parks on its industrial, remediated land, it is essential to adequately characterize the environment around such facilities to protect society, human health, and the environment. While DOE sites re considering several different land-use scenarios, all of them require adequate protection of the environment. Even if DOE lands are developed for energy parks that are mainly for industrializes sections of DOE lands that will not be remediated to residential standards, there is still the need to consider themore » protection of human health and the environment. We present an approach to characterization and establishment of teams that will gather the information, and integrate that information for a full range of stakeholders from technical personnel, to public policy makers, and that public. Such information is needed to establish baselines, site new energy facilities in energy parks, protect existing nuclear facilities and nuclear wastes, improve the basis for emergency planning, devise suitable monitoring schemes to ensure continued protection, provide data to track local and regional response changes, and for mitigation, remediation and decommissioning planning. We suggest that there are five categories of information or data needs, including 1) geophysical, sources, fate and transport, 2) biological systems, 3) human health, 4) stakeholder and environmental justice, and 5) societal, economic, and political. These informational needs are more expansive than the traditional site characterization, but encompass a suite of physical, biological, and societal needs to protect all aspects of human health and the environment, not just physical health. We suggest a Site Committee be established that oversees technical teams for each of the major informational categories, with appropriate representation among teams and with a

  3. A Wireless Physiological Signal Monitoring System with Integrated Bluetooth and WiFi Technologies.

    PubMed

    Yu, Sung-Nien; Cheng, Jen-Chieh

    2005-01-01

    This paper proposes a wireless patient monitoring system which integrates Bluetooth and WiFi wireless technologies. A wireless portable multi-parameter device was designated to acquire physiological signals and transmit them to a local server via Bluetooth wireless technology. Four kinds of monitor units were designed to communicate via the WiFi wireless technology, including a local monitor unit, a control center, mobile devices (personal digital assistant; PDA), and a web page. The use of various monitor units is intending to meet different medical requirements for different medical personnel. This system was demonstrated to promote the mobility and flexibility for both the patients and the medical personnel, which further improves the quality of health care.

  4. Cyanobacteria, Toxins and Indicators: Field Monitoring,Treatment Facility Monitoring and Treatment Studies

    EPA Science Inventory

    This presentation is a compilation of harmful algal bloom (HAB) related field monitoring data from the 2015 bloom season, treatment plant monitoring data from the 2013 and 2014 bloom seasons, and bench-scale treatment study data from 2015.

  5. Compressed Natural Gas Vehicle Maintenance Facility Modification Handbook

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kelly, K.; Melendez, M.; Gonzales, J.

    To ensure the safety of personnel and facilities, vehicle maintenance facilities are required by law and by guidelines of the National Fire Protection Association (NFPA) and the International Fire Code (IFC) to exhibit certain design features. They are also required to be fitted with certain fire protection equipment and devices because of the potential for fire or explosion in the event of fuel leakage or spills. All fuels have an explosion or fire potential if specific conditions are present. This handbook covers the primary elements that must be considered when developing a CNG vehicle maintenance facility design that will protectmore » against the ignition of natural gas releases. It also discusses specific protocols and training needed to ensure safety.« less

  6. Job attitudes toward the new maintenance concept of the Airway Facilities Service.

    DOT National Transportation Integrated Search

    1983-02-01

    To determine the attitudes of Airway FacilitieS (AF) personnel to the proposed New Maintenance Concept (NMC), an extensive questionnaire was mailed to all employees. Of 11,569 questionnaires distributed, 6,976 were completed and returned. Responses t...

  7. 49 CFR 193.2711 - Personnel health.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 3 2014-10-01 2014-10-01 false Personnel health. 193.2711 Section 193.2711 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY...: FEDERAL SAFETY STANDARDS Personnel Qualifications and Training § 193.2711 Personnel health. Each operator...

  8. 49 CFR 193.2711 - Personnel health.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Personnel health. 193.2711 Section 193.2711 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY...: FEDERAL SAFETY STANDARDS Personnel Qualifications and Training § 193.2711 Personnel health. Each operator...

  9. 49 CFR 193.2711 - Personnel health.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Personnel health. 193.2711 Section 193.2711 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY...: FEDERAL SAFETY STANDARDS Personnel Qualifications and Training § 193.2711 Personnel health. Each operator...

  10. 49 CFR 193.2711 - Personnel health.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 3 2012-10-01 2012-10-01 false Personnel health. 193.2711 Section 193.2711 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY...: FEDERAL SAFETY STANDARDS Personnel Qualifications and Training § 193.2711 Personnel health. Each operator...

  11. 49 CFR 193.2711 - Personnel health.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Personnel health. 193.2711 Section 193.2711 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY...: FEDERAL SAFETY STANDARDS Personnel Qualifications and Training § 193.2711 Personnel health. Each operator...

  12. Military Nutrition Research: Four Tasks to Address Personnel Readiness and Warfighter Performance

    DTIC Science & Technology

    2006-03-01

    protein turnover and gluconeogenesis, in fit individuals expending an additional 1000 calories while consuming a hypocaloric diet (deficit of 1000... hypocaloric diet (deficit of 1000 calories) that provides 55% of total calories from carbohydrate and 1.8 g protein/kg body weight. 4. Monitor plasma...Soldier Effectiveness $11,340,567 8/1/88-7/31/92 Effect of Food, Diet and Nutrition on Military Readiness and Preparedness of Army Personnel and

  13. Human and Organizational Risk Modeling: Critical Personnel and Leadership in Network Organizations

    DTIC Science & Technology

    2006-08-01

    NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) Carnegie Mellon University,School of Computer...Science,Pittsburgh,PA,15213 8. PERFORMING ORGANIZATION REPORT NUMBER 9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS(ES) 10. SPONSOR/MONITOR’S...organization can help improve performance and protect against the risk of loss. But the study of critical personnel has traditionally used static structural

  14. Airway hyperreactivity in asymptomatic military personnel.

    PubMed

    Morris, Michael J; Schwartz, Darin S; Nohrenberg, Jana L; Dooley, Sean N

    2007-11-01

    Asthma is frequently diagnosed in military personnel despite strict guidelines that disqualify persons with active disease or a recent history of asthma. It is generally considered incompatible with military service, because of the regular physical training, outdoor training exercises, and deployments to remote locations. The objective of this study was to determine the prevalence of airway hyperreactivity in asymptomatic military personnel, as an estimate of subclinical reactive airway disease. A prospective study of healthy, asymptomatic, military personnel with no previous history of asthma and <1 year on active duty status was conducted. After completion of a screening questionnaire, personnel underwent baseline spirometry with a portable spirometer. Personnel with obstructive indices (based on published guidelines) and matched control subjects participated in an exercise test (1.5-mile run), with pre- and postexercise spirometry. A total of 222 asymptomatic military personnel completed baseline spirometry, and 31 (14%) were found have airway obstruction. A normal matched control group of 31 military personnel and 26 personnel with obstruction performed exercise spirometry. Twenty-three percent of the participants with obstruction demonstrated increased airway hyper-reactivity after exercise, based on a reduction in forced expiratory volume at 1 second, compared with 19% of control subjects. Asymptomatic airway obstruction has a prevalence of 14% in young military personnel. A significant percentage of individuals also have evidence of worsening obstruction during exercise. These data suggest that screening spirometry may identify early reactive airway disease in asymptomatic individuals and should be considered as a method to identify persons predisposed to developing symptomatic asthma.

  15. Indirect Costs and Other Uses of Facilities Data at Institutions

    ERIC Educational Resources Information Center

    Watt, Catherine E.; Higerd, Thomas B.

    2007-01-01

    The purpose of this chapter is to examine possible uses for facilities data as they relate to three academic issues: classroom management, personnel management, and research activity. The number of institutions actively using space information to improve decision making is unknown. Most articles available in professional publications such as…

  16. 5 CFR 1631.4 - Public reference facilities and current index.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... index. 1631.4 Section 1631.4 Administrative Personnel FEDERAL RETIREMENT THRIFT INVESTMENT BOARD AVAILABILITY OF RECORDS Production or Disclosure of Records Under the Freedom of Information Act, 5 U.S.C. 552 § 1631.4 Public reference facilities and current index. (a) The Board maintains a public reading area...

  17. The Federal Aviation Administration's radar training facility and employee selection and training.

    DOT National Transportation Integrated Search

    1980-09-01

    The Federal Aviation Administration (FAA) has recently constructed a Radar Training Facility (RTF) in Oklahoma City, Oklahoma, to aid in screening appropriate personnel for work in radar air traffic control (ATC). The approach is based on the idea th...

  18. The Ames Power Monitoring System

    NASA Technical Reports Server (NTRS)

    Osetinsky, Leonid; Wang, David

    2003-01-01

    The Ames Power Monitoring System (APMS) is a centralized system of power meters, computer hardware, and specialpurpose software that collects and stores electrical power data by various facilities at Ames Research Center (ARC). This system is needed because of the large and varying nature of the overall ARC power demand, which has been observed to range from 20 to 200 MW. Large portions of peak demand can be attributed to only three wind tunnels (60, 180, and 100 MW, respectively). The APMS helps ARC avoid or minimize costly demand charges by enabling wind-tunnel operators, test engineers, and the power manager to monitor total demand for center in real time. These persons receive the information they need to manage and schedule energy-intensive research in advance and to adjust loads in real time to ensure that the overall maximum allowable demand is not exceeded. The APMS (see figure) includes a server computer running the Windows NT operating system and can, in principle, include an unlimited number of power meters and client computers. As configured at the time of reporting the information for this article, the APMS includes more than 40 power meters monitoring all the major research facilities, plus 15 Windows-based client personal computers that display real-time and historical data to users via graphical user interfaces (GUIs). The power meters and client computers communicate with the server using Transmission Control Protocol/Internet Protocol (TCP/IP) on Ethernet networks, variously, through dedicated fiber-optic cables or through the pre-existing ARC local-area network (ARCLAN). The APMS has enabled ARC to achieve significant savings ($1.2 million in 2001) in the cost of power and electric energy by helping personnel to maintain total demand below monthly allowable levels, to manage the overall power factor to avoid low power factor penalties, and to use historical system data to identify opportunities for additional energy savings. The APMS also

  19. Integrated gas analyzer for complete monitoring of turbine engine test cells.

    PubMed

    Markham, James R; Bush, Patrick M; Bonzani, Peter J; Scire, James J; Zaccardi, Vincent A; Jalbert, Paul A; Bryant, M Denise; Gardner, Donald G

    2004-01-01

    Fourier transform infrared (FT-IR) spectroscopy is proving to be reliable and economical for the quantification of many gas-phase species during testing and development of gas turbine engines in ground-based facilities such as sea-level test cells and altitude test cells. FT-IR measurement applications include engine-generated exhaust gases, facility air provided as input to engines, and ambient air in and around test cells. Potentially, the traditionally used assembly of many gas-specific single gas analyzers will be eliminated. However, the quest for a single instrument capable of complete gas-phase monitoring at turbine engine test cells has previously suffered since the FT-IR method cannot measure infrared-inactive oxygen molecules, a key operational gas to both air-breathing propulsion systems and test cell personnel. To further the quest, the FT-IR sensor used for the measurements presented in this article was modified by integration of a miniature, solid-state electrochemical oxygen sensor. Embedded in the FT-IR unit at a location near the long-effective-optical-path-length gas sampling cell, the amperometric oxygen sensor provides simultaneous, complementary information to the wealth of spectroscopic data provided by the FT-IR method.

  20. Atmospheric Reentry Materials and Structures Evaluation Facility (ARMSEF). User Test Planning Guide

    NASA Technical Reports Server (NTRS)

    2011-01-01

    Test process, milestones and inputs are unknowns to first-time users of the ARMSEF. The User Test Planning Guide aids in establishing expectations for both NASA and non-NASA facility customers. The potential audience for this guide includes both internal and commercial spaceflight hardware/software developers. It is intended to assist their test engineering personnel in test planning and execution. Material covered includes a roadmap of the test process, roles and responsibilities of facility and user, major milestones, facility capabilities, and inputs required by the facility. Samples of deliverables, test article interfaces, and inputs necessary to define test scope, cost, and schedule are included as an appendix to the guide.

  1. 21 CFR 225.10 - Personnel.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...) Qualified personnel and adequate personnel training and supervision are essential for the proper formulation, manufacture, and control of medicated feeds. Training and experience leads to proper use of equipment...

  2. 21 CFR 225.10 - Personnel.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ...) Qualified personnel and adequate personnel training and supervision are essential for the proper formulation, manufacture, and control of medicated feeds. Training and experience leads to proper use of equipment...

  3. The Personnel Effectiveness Grid (PEG): A New Tool for Estimating Personnel Department Effectiveness

    ERIC Educational Resources Information Center

    Petersen, Donald J.; Malone, Robert L.

    1975-01-01

    Examines the difficulties inherent in attempting a formal personnel evaluation system, the major formal methods currently used for evaluating personnel department accountabilities, some parameters that should be part of a valid evaluation program, and a model for conducting the evaluation. (Available from Office of Publications, Graduate School of…

  4. Final report on Weeks Island Monitoring Phase : 1999 through 2004.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ehgartner, Brian L.; Munson, Darrell Eugene

    2005-05-01

    This Final Report on the Monitoring Phase of the former Weeks Island Strategic Petroleum Reserve crude oil storage facility details the results of five years of monitoring of various surface accessible quantities at the decommissioned facility. The Weeks Island mine was authorized by the State of Louisiana as a Strategic Petroleum Reserve oil storage facility from 1979 until decommissioning of the facility in 1999. Discovery of a sinkhole over the facility in 1992 with freshwater inflow to the facility threatened the integrity of the oil storage and led to the decision to remove the oil, fill the chambers with brine,more » and decommission the facility. Thereafter, a monitoring phase, by agreement between the Department of Energy and the State, addressed facility stability and environmental concerns. Monitoring of the surface ground water and the brine of the underground chambers from the East Fill Hole produced no evidence of hydrocarbon contamination, which suggests that any unrecovered oil remaining in the underground chambers has been contained. Ever diminishing progression of the initial major sinkhole, and a subsequent minor sinkhole, with time was verification of the response of sinkholes to filling of the facility with brine. Brine filling of the facility ostensively eliminates any further growth or new formation from freshwater inflow. Continued monitoring of sinkhole response, together with continued surface surveillance for environmental problems, confirmed the intended results of brine pressurization. Surface subsidence measurements over the mine continued throughout the monitoring phase. And finally, the outward flow of brine was monitored as a measure of the creep closure of the mine chambers. Results of each of these monitoring activities are presented, with their correlation toward assuring the stability and environmental security of the decommissioned facility. The results suggest that the decommissioning was successful and no contamination of

  5. Staff Development Concerns for the Personnel Manager.

    ERIC Educational Resources Information Center

    Locke, William E.

    The most unique responsibility of the school personnel worker may be the evaluation of teachers. Unlike the personnel manager of a non-educational enterprise, a school personnel manager must provide remediation training to a tenured teacher not performing competently. Those involved in personnel decisions should be aware of what research has…

  6. Compliance with antimalarial chemoprophylaxis recommendations for wounded United States military personnel admitted to a military treatment facility.

    PubMed

    Rini, Elizabeth A; Weintrob, Amy C; Tribble, David R; Lloyd, Bradley A; Warkentien, Tyler E; Shaikh, Faraz; Li, Ping; Aggarwal, Deepak; Carson, M Leigh; Murray, Clinton K

    2014-06-01

    Malaria chemoprophylaxis is used as a preventive measure in military personnel deployed to malaria-endemic countries. However, limited information is available on compliance with chemoprophylaxis among trauma patients during hospitalization and after discharge. Therefore, we assessed antimalarial primary chemoprophylaxis and presumptive antirelapse therapy (primaquine) compliance among wounded United States military personnel after medical evacuation from Afghanistan (June 2009-August 2011) to Landstuhl Regional Medical Center in Landstuhl, Germany, and then to three U.S. military hospitals. Among admissions at Landstuhl Regional Medical Center, 74% of 2,540 patients were prescribed primary chemoprophylaxis and < 1% were prescribed primaquine. After transfer of 1,331 patients to U.S. hospitals, 93% received primary chemoprophylaxis and 33% received primaquine. Of 751 trauma patients with available post-admission data, 42% received primary chemoprophylaxis for four weeks, 33% received primaquine for 14 days, and 17% received both. These antimalarial chemoprophylaxis prescription rates suggest that improved protocols to continue malaria chemoprophylaxis in accordance with force protection guidelines are needed. © The American Society of Tropical Medicine and Hygiene.

  7. Exposure of hospital operating room personnel to potentially harmful environmental agents

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sass-Kortsak, A.M.; Purdham, J.T.; Bozek, P.R.

    1992-03-01

    Epidemiologic studies of risk to reproductive health arising from the operating room environment have been inconclusive and lack quantitative exposure information. This study was undertaken to quantify exposure of operating room (OR) personnel to anesthetic agents, x-radiation, methyl methacrylate, and ethylene oxide and to determine how exposure varies with different operating room factors. Exposures of anesthetists and nurses to these agents were determined in selected operating rooms over three consecutive days. Each subject was asked to wear an x-radiation dosimeter for 1 month. Exposure to anesthetic agents was found to be influenced by the age of the OR facility, typemore » of surgical service, number of procedures carried out during the day, type of anesthetic circuitry, and method of anesthesia delivery. Anesthetists were found to have significantly greater exposures than OR nurses. Exposure of OR personnel to ethylene oxide, methyl methacrylate, and x-radiation were well within existing standards. Exposure of anesthetists and nurses to anesthetic agents, at times, was in excess of Ontario exposure guidelines, despite improvements in the control of anesthetic pollution.« less

  8. 21 CFR 211.28 - Personnel responsibilities.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 4 2012-04-01 2012-04-01 false Personnel responsibilities. 211.28 Section 211.28 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS... from contamination. (b) Personnel shall practice good sanitation and health habits. (c) Only personnel...

  9. 21 CFR 211.28 - Personnel responsibilities.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 4 2013-04-01 2013-04-01 false Personnel responsibilities. 211.28 Section 211.28 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS... from contamination. (b) Personnel shall practice good sanitation and health habits. (c) Only personnel...

  10. 21 CFR 211.28 - Personnel responsibilities.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 4 2014-04-01 2014-04-01 false Personnel responsibilities. 211.28 Section 211.28 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS... from contamination. (b) Personnel shall practice good sanitation and health habits. (c) Only personnel...

  11. 21 CFR 211.28 - Personnel responsibilities.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 4 2011-04-01 2011-04-01 false Personnel responsibilities. 211.28 Section 211.28 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS... from contamination. (b) Personnel shall practice good sanitation and health habits. (c) Only personnel...

  12. 5 CFR 293.302 - Establishment of Official Personnel Folder.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Establishment of Official Personnel Folder. 293.302 Section 293.302 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS PERSONNEL RECORDS Official Personnel Folder § 293.302 Establishment of Official Personnel Folder...

  13. 5 CFR 293.302 - Establishment of Official Personnel Folder.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 5 Administrative Personnel 1 2011-01-01 2011-01-01 false Establishment of Official Personnel Folder. 293.302 Section 293.302 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS PERSONNEL RECORDS Official Personnel Folder § 293.302 Establishment of Official Personnel Folder...

  14. KENNEDY SPACE CENTER, FLA. - In the Launch Control Center, officials monitor the “Mode VII” emergency landing simulation being conducted at Kennedy Space Center and managed and directed from the LCC. From left are Dr. Luis Moreno and Dr. David Reed, with Bionetics Life Sciences, and Dr. Philip Scarpa, with the KSC Safety, Occupational Health and Environment Division. The purpose of the Mode VII is to exercise emergency preparedness personnel, equipment and facilities in rescuing astronauts from a downed orbiter and providing immediate medical attention. This simulation presents an orbiter that has crashed short of the Shuttle Landing Facility in a wooded area 2-1/2 miles south of Runway 33. Emergency crews are responding to the volunteer “astronauts” who are simulating various injuries inside the crew compartment mock-up. Rescuers must remove the crew, provide triage and transport to hospitals those who need further treatment. Local hospitals are participating in the exercise.

    NASA Image and Video Library

    2004-02-18

    KENNEDY SPACE CENTER, FLA. - In the Launch Control Center, officials monitor the “Mode VII” emergency landing simulation being conducted at Kennedy Space Center and managed and directed from the LCC. From left are Dr. Luis Moreno and Dr. David Reed, with Bionetics Life Sciences, and Dr. Philip Scarpa, with the KSC Safety, Occupational Health and Environment Division. The purpose of the Mode VII is to exercise emergency preparedness personnel, equipment and facilities in rescuing astronauts from a downed orbiter and providing immediate medical attention. This simulation presents an orbiter that has crashed short of the Shuttle Landing Facility in a wooded area 2-1/2 miles south of Runway 33. Emergency crews are responding to the volunteer “astronauts” who are simulating various injuries inside the crew compartment mock-up. Rescuers must remove the crew, provide triage and transport to hospitals those who need further treatment. Local hospitals are participating in the exercise.

  15. Overview of NORM and activities by a NORM licensed permanent decontamination and waste processing facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mirro, G.A.

    1997-02-01

    This paper presents an overview of issues related to handling NORM materials, and provides a description of a facility designed for the processing of NORM contaminated equipment. With regard to handling NORM materials the author discusses sources of NORM, problems, regulations and disposal options, potential hazards, safety equipment, and issues related to personnel protection. For the facility, the author discusses: description of the permanent facility; the operations of the facility; the license it has for handling specific radioactive material; operating and safety procedures; decontamination facilities on site; NORM waste processing capabilities; and offsite NORM services which are available.

  16. Developing State Agency Facility Plans: A Guide to Planning and Implementation. Michigan Studies in Rehabilitation Utilization Series: 4.

    ERIC Educational Resources Information Center

    Miller, Juliet V.; Wargel, James F.

    Intended for use in inservice training of vocational rehabilitation agency personnel, this facility planning guide is designed to (1) help state agencies understand the new facility planning requirements of the Rehabilitation Comprehensive Services and Developmental Disabilities Amendments of 1978, (2) provide information about a six-step planning…

  17. INTEGRATION OF FACILITY MODELING CAPABILITIES FOR NUCLEAR NONPROLIFERATION ANALYSIS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gorensek, M.; Hamm, L.; Garcia, H.

    2011-07-18

    Developing automated methods for data collection and analysis that can facilitate nuclear nonproliferation assessment is an important research area with significant consequences for the effective global deployment of nuclear energy. Facility modeling that can integrate and interpret observations collected from monitored facilities in order to ascertain their functional details will be a critical element of these methods. Although improvements are continually sought, existing facility modeling tools can characterize all aspects of reactor operations and the majority of nuclear fuel cycle processing steps, and include algorithms for data processing and interpretation. Assessing nonproliferation status is challenging because observations can come frommore » many sources, including local and remote sensors that monitor facility operations, as well as open sources that provide specific business information about the monitored facilities, and can be of many different types. Although many current facility models are capable of analyzing large amounts of information, they have not been integrated in an analyst-friendly manner. This paper addresses some of these facility modeling capabilities and illustrates how they could be integrated and utilized for nonproliferation analysis. The inverse problem of inferring facility conditions based on collected observations is described, along with a proposed architecture and computer framework for utilizing facility modeling tools. After considering a representative sampling of key facility modeling capabilities, the proposed integration framework is illustrated with several examples.« less

  18. 33 CFR 154.525 - Monitoring devices.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... monitoring devices at the facility would significantly limit the size of a discharge of oil or hazardous... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false Monitoring devices. 154.525...) POLLUTION FACILITIES TRANSFERRING OIL OR HAZARDOUS MATERIAL IN BULK Equipment Requirements § 154.525...

  19. 33 CFR 154.525 - Monitoring devices.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... monitoring devices at the facility would significantly limit the size of a discharge of oil or hazardous... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Monitoring devices. 154.525...) POLLUTION FACILITIES TRANSFERRING OIL OR HAZARDOUS MATERIAL IN BULK Equipment Requirements § 154.525...

  20. 33 CFR 154.525 - Monitoring devices.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... monitoring devices at the facility would significantly limit the size of a discharge of oil or hazardous... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false Monitoring devices. 154.525...) POLLUTION FACILITIES TRANSFERRING OIL OR HAZARDOUS MATERIAL IN BULK Equipment Requirements § 154.525...

  1. 33 CFR 154.525 - Monitoring devices.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... monitoring devices at the facility would significantly limit the size of a discharge of oil or hazardous... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false Monitoring devices. 154.525...) POLLUTION FACILITIES TRANSFERRING OIL OR HAZARDOUS MATERIAL IN BULK Equipment Requirements § 154.525...

  2. Facility shows benefit of staying single.

    PubMed

    Baillie, Jonathan

    2010-08-01

    Construction of the new 513-bed PFI-funded hospital in Pembury near Tunbridge Wells in Kent, a pound 227 million acute healthcare facility that, on its completion in the autumn of 2011, will be the UK's first to offer 100% single-bed en suite accommodation, is ahead of schedule, "thanks to excellent teamwork and careful planning". During a visit to the now rapidly emerging healthcare facility, located in an Area of Outstanding Natural Beauty (AONB) in a wooded hillside location in the Weald of Kent which Nigel Keen, general manager for the PFI project company, described as "the most attractive site for a hospital I have ever worked on", HEJ editor Jonathan Baillie met key project personnel and discussed the impressive progress made to date.

  3. International nuclear fuel cycle fact book. [Contains glossary of organizations, facilities, technical and other terms

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1992-09-01

    The International Nuclear Fuel Cycle Fact Book has been compiled in an effort to provide current data concerning fuel cycle and waste management facilities, R D programs and key personnel on 23 countries, including the US, four multi-national agencies, and 21 nuclear societies. The Fact Book is organized as follows: National summaries-a section for each country which summarizes nuclear policy, describes organizational relationships, and provides addresses and names of key personnel and information on facilities. International agencies-a section for each of the international agencies which has significant fuel cycle involvement and a listing of nuclear societies. Glossary-a list of abbreviations/acronymsmore » of organizations, facilities, technical and other terms. The national summaries, in addition to the data described above, feature a small map for each country as well as some general information. The latter presented from the perspective of the Fact Book user in the United States.« less

  4. Development of a Theory-Driven Injury Prevention Communication Strategy for U.S. Army Personnel

    DTIC Science & Technology

    2016-04-01

    for Soldiers, though medical personnel were also a priority audience group for communication products. Opportunities exist to expand on these...interventions that take on an ecological focus will use tailored and targeted messaging for individuals and groups and more broad techniques (e.g...program’s communication plan. The steps are referred to as analysis, strategic design , development and pretesting , implementation and monitoring

  5. Development of Experimental Army Enlisted Personnel Selection and Classification Tests and Job Performance Criteria

    DTIC Science & Technology

    2005-08-01

    Covers interaction of type, image, motion, sound, and sequence in Design staging for various media formats including commercials. 3 Computer Programming...the Behavioral & Social Sciences ARI 2511 Jefferson Davis Highway 11. MONITOR REPORT NUMBER Arlington, VA 22202-3926 Technical Report 1168 12...situational judgment test, and indicators of person-environment fit (e.g., job satisfaction). 15. SUBJECT TERMS Behavioral and social science Personnel

  6. Phased Demolition of an Occupied Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brede, Lawrence M.; Lauterbach, Merl J.; Witt, Brandon W.

    2008-01-15

    conducted while the tenants who were leasing floor space in the facility moved out. Upon completion of this phase the facility was turned over to the demolition project and the most hazardous materials were removed from the facility. Phase 2 activities included removing the process gas lines from sections C/D/E while decontaminating and preparing sections A and B for demolition. Demolition preparation activities include removing transit siding and universal waste from the area. Phase 3 began with demolition activities in sections A and B1 while continuing process gas line removal from sections C/D/E, as well as conducting demolition preparation activities to these sections. Area B was split into two sections, allowing demolition activities to occur in section B1 while personnel could still access the upper floor in sections C, D, and E. Once demolition began in section B2, personnel entry was only authorized in the basement. This timeline initiated phase 4, and the project completed cleaning the process components from the basement while section B2 demolition began. The final phase, phase 5, began once the basement was cleared. Final demolition activities began on sections C, D, E, and the basement. This material will ship for disposal and is scheduled for completion during FY07. Because the project was able to successfully phase demolition activities, the total facility demolition schedule was reduced by half to 2-1/2 years. The project was able to move portions of the demolition schedule from working in series to working in parallel, allowing the job to deliver facility demolition debris to ship for disposal 'just in time' as the facility was demolished.« less

  7. Influenza vaccination of health care personnel: Experiences with the first year of a national data collection effort.

    PubMed

    Kalayil, Elizabeth J; Dolan, Samantha B; Lindley, Megan C; Ahmed, Faruque

    2015-11-01

    The purpose of this project was to evaluate a standardized measure of health care personnel (HCP) influenza vaccination during the first year of implementation. The measure requires acute care hospitals to gather vaccination status data from employees, licensed independent practitioners (LIPs), and adult students/trainees and volunteers. The evaluation included a hospital sampling frame stratified by 4 United States Census Bureau Regions and hospital bed count. The hospitals were selected within strata using simple random sampling and the probability proportional to size method, without replacement. Semi-structured telephone interviews were conducted. Two qualitative data analysts independently coded each interview, and data were synthesized using a thematic analysis. This evaluation took place at hospitals reporting HCP influenza vaccination data as part of the Centers for Medicare & Medicaid Services Hospital Inpatient Quality Reporting (IQR) Program. Participants included the staff at 46 hospitals who were knowledgeable about data collection to fulfill IQR program requirements. Facilitators of data collection included having a small number of HCP, having a data collection system already in place, and providing HCP with advance notice of data collection. Major challenges included the absence of an established tracking process and monitoring HCP not regularly working in the facility, particularly LIPs. More than half of the facilities noted the time- and/or resource-intensive nature of data collection. Most facilities used data collected to meet other reporting requirements beyond the IQR Program. Hospitals implemented a range of data collection methods to comply with reporting requirements. Lessons learned from the first year of measure implementation can be used to enhance data collection practices across HCP groups for future influenza seasons. Copyright © 2015 Association for Professionals in Infection Control and Epidemiology, Inc. All rights reserved.

  8. Metrics for Success: Strategies for Enabling Core Facility Performance and Assessing Outcomes

    PubMed Central

    Hockberger, Philip E.; Meyn, Susan M.; Nicklin, Connie; Tabarini, Diane; Auger, Julie A.

    2016-01-01

    Core Facilities are key elements in the research portfolio of academic and private research institutions. Administrators overseeing core facilities (core administrators) require assessment tools for evaluating the need and effectiveness of these facilities at their institutions. This article discusses ways to promote best practices in core facilities as well as ways to evaluate their performance across 8 of the following categories: general management, research and technical staff, financial management, customer base and satisfaction, resource management, communications, institutional impact, and strategic planning. For each category, we provide lessons learned that we believe contribute to the effective and efficient overall management of core facilities. If done well, we believe that encouraging best practices and evaluating performance in core facilities will demonstrate and reinforce the importance of core facilities in the research and educational mission of institutions. It will also increase job satisfaction of those working in core facilities and improve the likelihood of sustainability of both facilities and personnel. PMID:26848284

  9. Metrics for Success: Strategies for Enabling Core Facility Performance and Assessing Outcomes.

    PubMed

    Turpen, Paula B; Hockberger, Philip E; Meyn, Susan M; Nicklin, Connie; Tabarini, Diane; Auger, Julie A

    2016-04-01

    Core Facilities are key elements in the research portfolio of academic and private research institutions. Administrators overseeing core facilities (core administrators) require assessment tools for evaluating the need and effectiveness of these facilities at their institutions. This article discusses ways to promote best practices in core facilities as well as ways to evaluate their performance across 8 of the following categories: general management, research and technical staff, financial management, customer base and satisfaction, resource management, communications, institutional impact, and strategic planning. For each category, we provide lessons learned that we believe contribute to the effective and efficient overall management of core facilities. If done well, we believe that encouraging best practices and evaluating performance in core facilities will demonstrate and reinforce the importance of core facilities in the research and educational mission of institutions. It will also increase job satisfaction of those working in core facilities and improve the likelihood of sustainability of both facilities and personnel.

  10. Design Criteria for Microbiological Facilities at Fort Detrick. Volume I: Introduction.

    ERIC Educational Resources Information Center

    Army Biological Labs., Fort Detrick, MD. Industrial Health and Safety Div.

    Volume I of a two volume manual serves as an introduction to design criteria for microbiological facilities. It is addressed to management personnel responsible for planning, budgeting, and making policy decisions for construction or remodeling of microbiological research laboratories. This volume is also concerned with--(1) microbiological safety…

  11. Advantages and Disadvantages of the National Security Personnel System as Compared to the General Schedule Personnel System

    DTIC Science & Technology

    2005-12-01

    NAVAL POSTGRADUATE SCHOOL MONTEREY, CALIFORNIA JOINT APPLIED PROJECT Advantages and Disadvantages of the National Security...Applied Project 4. TITLE AND SUBTITLE: Advantages and Disadvantages of the National Security Personnel System as Compared to the General...compare and contrast the advantages and disadvantages of the new personnel system (NSPS) versus the General Schedule (GS) personnel system currently

  12. A survey of veterinary radiation facilities in 2010.

    PubMed

    Farrelly, John; McEntee, Margaret C

    2014-01-01

    A survey of veterinary radiation therapy facilities in the United States, Canada, and Europe was done in 2010, using an online survey tool, to determine the type of equipment available, radiation protocols used, caseload, tumor types irradiated, as well as other details of the practice of veterinary radiation oncology. The results of this survey were compared to a similar survey performed in 2001. A total of 76 facilities were identified including 24 (32%) academic institutions and 52 (68%) private practice external beam radiation therapy facilities. The overall response rate was 51% (39/76 responded). Based on this survey, there is substantial variation among facilities in all aspects ranging from equipment and personnel to radiation protocols and caseloads. American College of Veterinary Radiology boarded radiation oncologists direct 90% of the radiation facilities, which was increased slightly compared to 2001. All facilities surveyed in 2010 had a linear accelerator. More facilities reported having electron capability (79%) compared to the 2001 survey. Eight facilities had a radiation oncology resident, and academic facilities were more likely to have residents. Patient caseload information was available from 28 sites (37% of radiation facilities), and based on the responses 1376 dogs and 352 cats were irradiated in 2010. The most frequently irradiated tumors were soft tissue sarcomas in dogs, and oral squamous cell carcinoma in cats. © 2014 American College of Veterinary Radiology.

  13. Facility fence-line monitoring using passive samplers

    EPA Science Inventory

    In 2009, the U.S. EPA executed a year-long field study at a refinery in Corpus Christi, Texas, to evaluate the use of passive diffusive sampling technology for assessing time-averaged benzene concentrations at the facility fence line. The study utilized 14-day time-integrated Car...

  14. Monitoring Students' Academic & Disciplinary Progression.

    ERIC Educational Resources Information Center

    McDonald, Fred; Kellogg, Larry J.

    This document outlines the objectives and procedures of a program at a New Mexico school district whose purpose is to enable school personnel to systematically monitor students' academic and disciplinary progression. The objectives of the program are to diagnose academic or disciplinary problems and prescribe remedies, to establish an oncampus…

  15. Hazard and operability study of the multi-function Waste Tank Facility. Revision 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hughes, M.E.

    1995-05-15

    The Multi-Function Waste Tank Facility (MWTF) East site will be constructed on the west side of the 200E area and the MWTF West site will be constructed in the SW quadrant of the 200W site in the Hanford Area. This is a description of facility hazards that site personnel or the general public could potentially be exposed to during operation. A list of preliminary Design Basis Accidents was developed.

  16. Evaluating the Treatment Costs for Uncomplicated Malaria at a Public Healthcare Facility in Nigeria and the Implications.

    PubMed

    Ezenduka, Charles C; Falleiros, Daniel Resende; Godman, Brian B

    2017-09-01

    Accurate information on the facility costs of treatment is essential to enhance decision making and funding for malaria control. The objective of this study was to estimate the costs of providing treatment for uncomplicated malaria through a public health facility in Nigeria. Hospital costs were estimated from a provider perspective, applying a standard costing procedure. Capital and recurrent expenditures were estimated using an ingredient approach combined with step-down methodology. Costs attributable to malaria treatment were calculated based on the proportion of malaria cases to total outpatient visits. The costs were calculated in local currency [Naira (N)] and converted to US dollars at the 2013 exchange rate. Total annual costs of N28.723 million (US$182,953.65) were spent by the facility on the treatment of uncomplicated malaria, at a rate of US$31.49 per case, representing approximately 25% of the hospital's total expenditure in the study year. Personnel accounted for over 82.5% of total expenditure, followed by antimalarial medicines at 6.6%. More than 45% of outpatients visits were for uncomplicated malaria. Changes in personnel costs, drug prices and malaria prevalence significantly impacted on the study results, indicating the need for improved efficiency in the use of hospital resources. Malaria treatment currently consumes a considerable amount of resources in the facility, driven mainly by personnel cost and a high proportion of malaria cases. There is scope for enhanced efficiency to prevent waste and reduce costs to the provider and ultimately the consumer.

  17. Navy-wide Personnel Survey (NPS) 2007-2008: Tabulated Results

    DTIC Science & Technology

    2011-02-01

    wide Personnel Survey (NPS) is a major product of the Navy Personnel Survey System ( NPSS ). Administered regularly by the Navy Personnel Research...2008 NPS was conducted under the sponsorship of the Chief of Naval Personnel (N1) within the Navy Personnel Survey System ( NPSS ) funding line...the Chief of Naval Personnel instituted the Navy Personnel Survey System ( NPSS ) as a means of collecting and organizing information regarding the

  18. EPA Facility Registry Service (FRS): Facility Interests Dataset Download

    EPA Pesticide Factsheets

    This downloadable data package consists of location and facility identification information from EPA's Facility Registry Service (FRS) for all sites that are available in the FRS individual feature layers. The layers comprise the FRS major program databases, including:Assessment Cleanup and Redevelopment Exchange System (ACRES) : brownfields sites ; Air Facility System (AFS) : stationary sources of air pollution ; Air Quality System (AQS) : ambient air pollution data from monitoring stations; Bureau of Indian Affairs (BIA) : schools data on Indian land; Base Realignment and Closure (BRAC) facilities; Clean Air Markets Division Business System (CAMDBS) : market-based air pollution control programs; Comprehensive Environmental Response, Compensation, and Liability Information System (CERCLIS) : hazardous waste sites; Integrated Compliance Information System (ICIS) : integrated enforcement and compliance information; National Compliance Database (NCDB) : Federal Insecticide, Fungicide, and Rodenticide Act (FIFRA) and the Toxic Substances Control Act (TSCA); National Pollutant Discharge Elimination System (NPDES) module of ICIS : NPDES surface water permits; Radiation Information Database (RADINFO) : radiation and radioactivity facilities; RACT/BACT/LAER Clearinghouse (RBLC) : best available air pollution technology requirements; Resource Conservation and Recovery Act Information System (RCRAInfo) : tracks generators, transporters, treaters, storers, and disposers

  19. Quality assurance procedures for environmental control and monitoring in plant growth facilities. Report of the North Central Regional 101 Committee on Growth Chamber Use

    NASA Technical Reports Server (NTRS)

    Tibbitts, T. W. (Principal Investigator)

    1986-01-01

    This report includes procedures for ensuring the quality of the environment provided for plant growth in controlled environment facilities. Biologists and engineers may use these procedures for ensuring quality control during experiments or for ensuring quality control in the design of plant growth facilities. Environmental monitoring prior to and during experiments is included in these procedures. Specific recommendations cover control, acquisition, and calibration for sensor types for the separate parameters of radiation (light), temperature, humidity, carbon dioxide, and air movement.

  20. Test Plan for the Wake Steering Experiment at the Scaled Wind Farm Technology (SWiFT) Facility.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Naughton, Brian Thomas

    This document is a test plan describing the objectives, configuration, procedures, reporting, roles, and responsibilities for conducting the joint Sandia National Laboratories and National Renewable Energy Laboratory Wake Steering Experiment at the Sandia Scaled Wind Farm Technology (SWiFT) facility near Lubbock, Texas in 2016 and 2017 . The purpose of this document is to ensure the test objectives and procedures are sufficiently detailed such that al l involved personnel are able to contribute to the technical success of the test. This document is not intended to address safety explicitly which is addressed in a separate document listed in the referencesmore » titled Sandia SWiFT Facility Site Operations Manual . Both documents should be reviewed by all test personnel.« less

  1. 20 CFR 416.1021 - Personnel.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 20 Employees' Benefits 2 2010-04-01 2010-04-01 false Personnel. 416.1021 Section 416.1021 Employees' Benefits SOCIAL SECURITY ADMINISTRATION SUPPLEMENTAL SECURITY INCOME FOR THE AGED, BLIND, AND DISABLED Determinations of Disability Administrative Responsibilities and Requirements § 416.1021 Personnel...

  2. 20 CFR 404.1621 - Personnel.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 20 Employees' Benefits 2 2010-04-01 2010-04-01 false Personnel. 404.1621 Section 404.1621 Employees' Benefits SOCIAL SECURITY ADMINISTRATION FEDERAL OLD-AGE, SURVIVORS AND DISABILITY INSURANCE (1950- ) Determinations of Disability Administrative Responsibilities and Requirements § 404.1621 Personnel. (a) Equal...

  3. EPA Facility Registry Service (FRS): Facility Interests Dataset

    EPA Pesticide Factsheets

    This web feature service consists of location and facility identification information from EPA's Facility Registry Service (FRS) for all sites that are available in the FRS individual feature layers. The layers comprise the FRS major program databases, including:Assessment Cleanup and Redevelopment Exchange System (ACRES) : brownfields sites ; Air Facility System (AFS) : stationary sources of air pollution ; Air Quality System (AQS) : ambient air pollution data from monitoring stations; Bureau of Indian Affairs (BIA) : schools data on Indian land; Base Realignment and Closure (BRAC) facilities; Clean Air Markets Division Business System (CAMDBS) : market-based air pollution control programs; Comprehensive Environmental Response, Compensation, and Liability Information System (CERCLIS) : hazardous waste sites; Integrated Compliance Information System (ICIS) : integrated enforcement and compliance information; National Compliance Database (NCDB) : Federal Insecticide, Fungicide, and Rodenticide Act (FIFRA) and the Toxic Substances Control Act (TSCA); National Pollutant Discharge Elimination System (NPDES) module of ICIS : NPDES surface water permits; Radiation Information Database (RADINFO) : radiation and radioactivity facilities; RACT/BACT/LAER Clearinghouse (RBLC) : best available air pollution technology requirements; Resource Conservation and Recovery Act Information System (RCRAInfo) : tracks generators, transporters, treaters, storers, and disposers of haz

  4. Measuring the Efficient Utilization of Medical Personnel at Navy Military Treatment Facilities

    DTIC Science & Technology

    1990-06-01

    measures of effectiveness (MOE) for utilizing manpower at a medical treatment facility by analyzing data from Navy hospitals. The MOE will be able to...at Navy facili- ties will be used to compare alternative MOEs., The data resources are categorized into expenditures, Naval health-care statistics ...of years., At the Office of the Chief of Naval Operations, OP-801 maintains financial data of medical budgets, 2. NAVAL HEALTH-CARE STATISTICS The

  5. LPT. Shield test facility test building interior (TAN646). Camera points ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    LPT. Shield test facility test building interior (TAN-646). Camera points down into interior of north pool. Equipment on wall is electronical bus used for post-1970 experiment. Personnel ladder at right. INEEL negative no. HD-40-9-1 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  6. Restoration of the Hypersonic Tunnel Facility at NASA Glenn Research Center, Plum Brook Station

    NASA Technical Reports Server (NTRS)

    Woodling, Mark A.

    2000-01-01

    The NASA Glenn Research Center's Hypersonic Tunnel Facility (HTF), located at the Plum Brook Station in Sandusky, Ohio, is a non-vitiated, free-jet facility, capable of testing large-scale propulsion systems at Mach Numbers from 5 to 7. As a result of a component failure in September of 1996, a restoration project was initiated in mid- 1997 to repair the damage to the facility. Following the 2-1/2 year effort, the HTF has been returned to an operational condition. Significant repairs and operational improvements have been implemented in order to ensure facility reliability and personnel safety. As of January 2000, this unique, state-of-the-art facility was ready for integrated systems testing.

  7. Electromagnetic Interference/Compatibility (EMI/EMC) Control Test and Measurement Facility: User Test Planning Guide

    NASA Technical Reports Server (NTRS)

    Scully, Robert C.

    2011-01-01

    Test process, milestones and inputs are unknowns to first-time users of the EMI/EMC Test Facility. The User Test Planning Guide aids in establishing expectations for both NASA and non-NASA facility customers. The potential audience for this guide includes both internal and commercial spaceflight hardware/software developers. It is intended to assist their test engineering personnel in test planning and execution. Material covered includes a roadmap of the test process, roles and responsibilities of facility and user, major milestones, facility capabilities, and inputs required by the facility. Samples of deliverables, test article interfaces, and inputs necessary to define test scope, cost, and schedule are included as an appendix to the guide.

  8. Biosecurity measures in 48 isolation facilities managing highly infectious diseases.

    PubMed

    Puro, Vincenzo; Fusco, Francesco M; Schilling, Stefan; Thomson, Gail; De Iaco, Giuseppina; Brouqui, Philippe; Maltezou, Helena C; Bannister, Barbara; Gottschalk, René; Brodt, Hans-Rheinhard; Ippolito, Giuseppe

    2012-06-01

    Biosecurity measures are traditionally applied to laboratories, but they may also be usefully applied in highly specialized clinical settings, such as the isolation facilities for the management of patients with highly infectious diseases (eg, viral hemorrhagic fevers, SARS, smallpox, potentially severe pandemic flu, and MDR- and XDR-tuberculosis). In 2009 the European Network for Highly Infectious Diseases conducted a survey in 48 isolation facilities in 16 European countries to determine biosecurity measures for access control to the facility. Security personnel are present in 39 facilities (81%). In 35 facilities (73%), entrance to the isolation area is restricted; control methods include electronic keys, a PIN system, closed-circuit TV, and guards at the doors. In 25 facilities (52%), identification and registration of all staff entering and exiting the isolation area are required. Access control is used in most surveyed centers, but specific lacks exist in some facilities. Further data are needed to assess other biosecurity aspects, such as the security measures during the transportation of potentially contaminated materials and measures to address the risk of an "insider attack."

  9. Refurbishment and Automation of Thermal Vacuum Facilities at NASA/GSFC

    NASA Technical Reports Server (NTRS)

    Dunn, Jamie; Gomez, Carlos; Donohue, John; Johnson, Chris; Palmer, John; Sushon, Janet

    1999-01-01

    The thermal vacuum facilities located at the Goddard Space Flight Center (GSFC) have supported both manned and unmanned space flight since the 1960s. Of the eleven facilities, currently ten of the systems are scheduled for refurbishment or replacement as part of a five-year implementation. Expected return on investment includes the reduction in test schedules, improvements in safety of facility operations, and reduction in the personnel support required for a test. Additionally, GSFC will become a global resource renowned for expertise in thermal engineering, mechanical engineering, and for the automation of thermal vacuum facilities and tests. Automation of the thermal vacuum facilities includes the utilization of Programmable Logic Controllers (PLCs), the use of Supervisory Control and Data Acquisition (SCADA) systems, and the development of a centralized Test Data Management System. These components allow the computer control and automation of mechanical components such as valves and pumps. The project of refurbishment and automation began in 1996 and has resulted in complete computer control of one facility (Facility 281), and the integration of electronically controlled devices and PLCs in multiple others.

  10. Refurbishment and Automation of Thermal Vacuum Facilities at NASA/GSFC

    NASA Technical Reports Server (NTRS)

    Dunn, Jamie; Gomez, Carlos; Donohue, John; Johnson, Chris; Palmer, John; Sushon, Janet

    1998-01-01

    The thermal vacuum facilities located at the Goddard Space Flight Center (GSFC) have supported both manned and unmanned space flight since the 1960s. Of the eleven facilities, currently ten of the systems are scheduled for refurbishment or replacement as part of a five-year implementation. Expected return on investment includes the reduction in test schedules, improvements in safety of facility operations, and reduction in the personnel support required for a test. Additionally, GSFC will become a global resource renowned for expertise in thermal engineering, mechanical engineering, and for the automation of thermal vacuum facilities and tests. Automation of the thermal vacuum facilities includes the utilization of Programmable Logic Controllers (PLCs), the use of Supervisory Control and Data Acquisition (SCADA) systems, and the development of a centralized Test Data Management System. These components allow the computer control and automation of mechanical components such as valves and pumps. The project of refurbishment and automation began in 1996 and has resulted in complete computer control of one facility (Facility 281), and the integration of electronically controlled devices and PLCs in multiple others.

  11. Biosecurity Measures in 48 Isolation Facilities Managing Highly Infectious Diseases

    PubMed Central

    Puro, Vincenzo; Schilling, Stefan; Thomson, Gail; De Iaco, Giuseppina; Brouqui, Philippe; Maltezou, Helena C.; Bannister, Barbara; Gottschalk, René; Brodt, Hans-Rheinhard; Ippolito, Giuseppe

    2012-01-01

    Biosecurity measures are traditionally applied to laboratories, but they may also be usefully applied in highly specialized clinical settings, such as the isolation facilities for the management of patients with highly infectious diseases (eg, viral hemorrhagic fevers, SARS, smallpox, potentially severe pandemic flu, and MDR- and XDR-tuberculosis). In 2009 the European Network for Highly Infectious Diseases conducted a survey in 48 isolation facilities in 16 European countries to determine biosecurity measures for access control to the facility. Security personnel are present in 39 facilities (81%). In 35 facilities (73%), entrance to the isolation area is restricted; control methods include electronic keys, a PIN system, closed-circuit TV, and guards at the doors. In 25 facilities (52%), identification and registration of all staff entering and exiting the isolation area are required. Access control is used in most surveyed centers, but specific lacks exist in some facilities. Further data are needed to assess other biosecurity aspects, such as the security measures during the transportation of potentially contaminated materials and measures to address the risk of an “insider attack.” PMID:22571373

  12. Hydrologic Instrumentation Facility of the U.S. Geological Survey, annual report for fiscal year 1993

    USGS Publications Warehouse

    Latkovich, V.J.; Tracey, Debra C.

    1994-01-01

    The Hydrologic lnstrumentation Facility (HIF) of the U.S. Geological Survey (USGS) has nationwide responsibility for all aspects of hydrologic field instrumentation in support of Survey data-collection programs. Each year the HIF publishes a report to inform Water Resources Division (WRD) personnel of progress made by the HIF in fulfilling its mission to improve instrumentation services to the Division. The report for fiscal year 1993 (FY93) describes the activities of the HIF, including major accomplish- ments for the year; personnel actions; active projects (reported by section--Technical Services Section, Administrative Services Section, Field Coordination, Applications and Development Section, Test and Evaluation Section, Field Service and Supply Section); and planned activities for the coming year. Also presented in the appendixes are detailed listings of the memberships of the Instrumentation Committee and the Instrumentation Technical Advisory Subcommittee; district, sub- district, and field office visits by HIF personnel; professional and technical meetings attended by HIF personnel; vendor visits; and reports prepared by HIF personnel.

  13. 29 CFR 1917.27 - Personnel.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 29 Labor 7 2011-07-01 2011-07-01 false Personnel. 1917.27 Section 1917.27 Labor Regulations...) MARINE TERMINALS Marine Terminal Operations § 1917.27 Personnel. (a) Qualifications of machinery...) elements of accident prevention; (iii) attitudes, leadership and motivation; (iv) hazards of longshoring...

  14. 21 CFR 58.29 - Personnel.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL GOOD LABORATORY PRACTICE FOR NONCLINICAL LABORATORY STUDIES Organization and Personnel § 58.29 Personnel. (a) Each individual engaged in the conduct of or responsible for the supervision of a nonclinical laboratory study shall have...

  15. The Dartnell Personnel Director's Handbook.

    ERIC Educational Resources Information Center

    Scheer, Wilbert E.

    This handbook for personnel directors is designed to help improve the acquisition, selection, development, welfare, and general administration and control of business and industrial employees. Overall objectives and functions of personnel management are considered first. Part 2 (Employment) stresses advance planning; recruiting and interviewing;…

  16. Ground-water monitoring compliance projects for Hanford Site facilities: Volume 1, The report and Appendix A, Progress report for the period October 1 to December 31, 1986

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    This report documents recent progress on ground-water monitoring projects for four Hanford Site facilities: the 300 Area Process Trenches, the 183-H Solar Evaporation Basins, the 200 Area Low-Level Burial Grounds, and the Nonradioactive Dangerous Waste (NRDW) Landfill. The existing ground-water monitoring projects for the first two facilities named in the paragraph above are currently being expanded by adding new wells to the networks. During the reporting period, sampling of the existing wells continued on a monthly basis, and the analytical results for samples collected from September through November 1986 are included and discussed in this document. 8 refs., 41 figs.,more » 7 tabs.« less

  17. In-theater hospitalizations of US and allied personnel during the 1991 Gulf War.

    PubMed

    Smith, Tyler C; Corbeil, Thomas E; Ryan, Margaret A K; Heller, Jack M; Gray, Gregory C

    2004-06-01

    The postwar morbidity of Gulf War veterans has been closely examined. However, data have not been available to evaluate morbidity suffered during the 1991 Gulf War. In this report, the authors examine archived records of hospitalizations in US military facilities in the Kuwaiti theater of operations or those medically evacuated to facilities in Europe. Using multivariable logistic regression modeling, the authors determined that service personnel at greatest odds for "in-theater" hospitalization were enlisted, female, White, Reservist, Army, and health care workers. No increase in odds was observed for oil well fire smoke exposure or possible exposure to the nerve agent hazard areas. Although these data may be incomplete, they represent the best-known data reflecting in-theater hospitalizations during the Gulf War of 1991 and show remarkable similarities in risk factors to those for postwar hospitalization.

  18. A microcomputer-based whole-body counter for personnel routine monitoring.

    PubMed

    Chou, H P; Tsai, T M; Lan, C Y

    1993-05-01

    The paper describes a cost-effective NaI(Tl) whole-body counter developed for routine examinations of worker intakes at an isotope production facility. Signal processing, data analysis and system operation are microcomputer-controlled for minimum human interactions. The pulse height analyzer is developed as an microcomputer add-on card for easy manipulation. The scheme for radionuclide analysis is aimed for fast running according to a knowledge base established from background samples and phantom experiments in conjunction with a multivariate regression analysis. Long-term stability and calibration with standards and in vivo measurements are reported.

  19. KENNEDY SPACE CENTER, FLA. - An “injured” rescue worker is lifted into an M-113 armored personnel carrier provided for transportation during a “Mode VII” emergency landing simulation at Kennedy Space Center. The purpose of the Mode VII is to exercise emergency preparedness personnel, equipment and facilities in rescuing astronauts from a downed orbiter and providing immediate medical attention. This simulation presents an orbiter that has crashed short of the Shuttle Landing Facility in a wooded area 2-1/2 miles south of Runway 33. Emergency crews are responding to the volunteer astronauts who are simulating various injuries inside the crew compartment mock-up. Rescuers must remove the crew, provide triage and transport to hospitals those who need further treatment. Local hospitals are participating in the exercise.

    NASA Image and Video Library

    2004-02-18

    KENNEDY SPACE CENTER, FLA. - An “injured” rescue worker is lifted into an M-113 armored personnel carrier provided for transportation during a “Mode VII” emergency landing simulation at Kennedy Space Center. The purpose of the Mode VII is to exercise emergency preparedness personnel, equipment and facilities in rescuing astronauts from a downed orbiter and providing immediate medical attention. This simulation presents an orbiter that has crashed short of the Shuttle Landing Facility in a wooded area 2-1/2 miles south of Runway 33. Emergency crews are responding to the volunteer astronauts who are simulating various injuries inside the crew compartment mock-up. Rescuers must remove the crew, provide triage and transport to hospitals those who need further treatment. Local hospitals are participating in the exercise.

  20. 41 CFR 50-204.23 - Precautionary procedures and personnel monitoring.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... monitoring. (a) Every employer shall make such surveys as may be necessary for him to comply with the provisions in this subpart. “Survey” means an evaluation of the radiation hazards incident to the production... specific set of conditions. When appropriate, such evaluation includes a physical survey of the location of...

  1. 41 CFR 50-204.23 - Precautionary procedures and personnel monitoring.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... monitoring. (a) Every employer shall make such surveys as may be necessary for him to comply with the provisions in this subpart. “Survey” means an evaluation of the radiation hazards incident to the production... specific set of conditions. When appropriate, such evaluation includes a physical survey of the location of...

  2. 41 CFR 50-204.23 - Precautionary procedures and personnel monitoring.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... monitoring. (a) Every employer shall make such surveys as may be necessary for him to comply with the provisions in this subpart. “Survey” means an evaluation of the radiation hazards incident to the production... specific set of conditions. When appropriate, such evaluation includes a physical survey of the location of...

  3. 41 CFR 50-204.23 - Precautionary procedures and personnel monitoring.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... monitoring. (a) Every employer shall make such surveys as may be necessary for him to comply with the provisions in this subpart. “Survey” means an evaluation of the radiation hazards incident to the production... specific set of conditions. When appropriate, such evaluation includes a physical survey of the location of...

  4. 41 CFR 50-204.23 - Precautionary procedures and personnel monitoring.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... monitoring. (a) Every employer shall make such surveys as may be necessary for him to comply with the provisions in this subpart. “Survey” means an evaluation of the radiation hazards incident to the production... specific set of conditions. When appropriate, such evaluation includes a physical survey of the location of...

  5. 5 CFR 575.212 - Internal monitoring requirements and revocation or suspension of authority.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Internal monitoring requirements and... MANAGEMENT CIVIL SERVICE REGULATIONS RECRUITMENT, RELOCATION, AND RETENTION INCENTIVES; SUPERVISORY DIFFERENTIALS; AND EXTENDED ASSIGNMENT INCENTIVES Relocation Incentives § 575.212 Internal monitoring...

  6. 5 CFR 575.312 - Internal monitoring requirements and revocation or suspension of authority.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Internal monitoring requirements and... MANAGEMENT CIVIL SERVICE REGULATIONS RECRUITMENT, RELOCATION, AND RETENTION INCENTIVES; SUPERVISORY DIFFERENTIALS; AND EXTENDED ASSIGNMENT INCENTIVES Retention Incentives § 575.312 Internal monitoring...

  7. 76 FR 81359 - National Security Personnel System

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-28

    ... contains regulatory documents #0;having general applicability and legal effect, most of which are keyed #0... Security Personnel System AGENCY: Department of Defense; Office of Personnel Management. ACTION: Final rule... concerning the National Security Personnel System (NSPS). Section 1113 of the National Defense Authorization...

  8. 78 FR 43796 - Indebtedness of Military Personnel

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-22

    ... DEPARTMENT OF DEFENSE Department of the Army 32 CFR Part 513 Indebtedness of Military Personnel... regulations concerning indebtedness of military personnel. The regulations are being removed because they are... policy and guidance codified at 32 CFR Part 112, ``Indebtedness of Military Personnel,'' and DoD...

  9. Modeling Personnel Turnover in the Parametric Organization

    NASA Technical Reports Server (NTRS)

    Dean, Edwin B.

    1991-01-01

    A primary issue in organizing a new parametric cost analysis function is to determine the skill mix and number of personnel required. The skill mix can be obtained by a functional decomposition of the tasks required within the organization and a matrixed correlation with educational or experience backgrounds. The number of personnel is a function of the skills required to cover all tasks, personnel skill background and cross training, the intensity of the workload for each task, migration through various tasks by personnel along a career path, personnel hiring limitations imposed by management and the applicant marketplace, personnel training limitations imposed by management and personnel capability, and the rate at which personnel leave the organization for whatever reason. Faced with the task of relating all of these organizational facets in order to grow a parametric cost analysis (PCA) organization from scratch, it was decided that a dynamic model was required in order to account for the obvious dynamics of the forming organization. The challenge was to create such a simple model which would be credible during all phases of organizational development. The model development process was broken down into the activities of determining the tasks required for PCA, determining the skills required for each PCA task, determining the skills available in the applicant marketplace, determining the structure of the dynamic model, implementing the dynamic model, and testing the dynamic model.

  10. 77 FR 13206 - Protective Force Personnel Medical, Physical Readiness, Training, and Access Authorization Standards

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-06

    ...The Department of Energy (DOE or Department) proposes to revise the regulation governing the standards for medical, physical performance, training, and access authorizations for protective force (PF) personnel employed by contractors providing security services to the Department. The existing version of this regulation was promulgated in 1993 and substantial portions of the regulation date to the mid- 1980s. Since 1993 DOE policy has placed greater reliance upon technology, vehicular response, and increased firepower and, correspondingly, has reduced its reliance upon the ability of PF personnel to perform the running tasks required in the current regulation. Furthermore, this shift in emphasis has placed a greater premium upon the retention of mature, tactically experienced, and technically sophisticated personnel, particularly since these personnel represent a considerable investment by DOE in security background investigations and training. The proposed revisions bring DOE PF medical and physical readiness requirements in line with these tactical and organizational priorities. The proposed revisions reduce the exposure of the PF population to injuries related to physical readiness testing. They would create a PF readiness classification designed specifically to encourage the retention of experienced personnel. The revisions would further ensure that PF personnel would be evaluated on a case-by-case basis on their ability to perform the essential functions of their positions without posing a direct threat to themselves or site personnel, the facility, or the general public. The proposed revisions would further ensure that reasonable accommodations would be considered before a determination is made that an individual cannot perform the essential functions of a particular position. The proposed rule also would provide for new medical review processes for PF personnel disqualified from medical certification. The proposed rule would ensure that DOE PF medical and

  11. Sleep Disorders and Associated Medical Comorbidities in Active Duty Military Personnel

    PubMed Central

    Mysliwiec, Vincent; McGraw, Leigh; Pierce, Roslyn; Smith, Patrick; Trapp, Brandon; Roth, Bernard J.

    2013-01-01

    Study Objectives: Describe the prevalence of sleep disorders in military personnel referred for polysomnography and identify relationships between demographic characteristics, comorbid diagnoses, and specific sleep disorders. Design: Retrospective cross-sectional study. Setting: Military medical treatment facility. Participants: Active duty military personnel with diagnostic polysomnogram in 2010. Measurements: Primary sleep disorder rendered by review of polysomnogram and medical record by a board certified sleep medicine physician. Demographic characteristics and conditions of posttraumatic stress disorder (PTSD), mild traumatic brain injury (mTBI), anxiety, depression, and pain syndromes determined by medical record review. Results: Primary sleep diagnoses (n = 725) included: mild obstructive sleep apnea (OSA), 207 (27.2%); insomnia, 188 (24.7%); moderate-to-severe OSA, 183 (24.0 %); and paradoxical insomnia,39 (5.1%); behaviorally induced insufficient sleep syndrome, 68 (8.9%) and snoring, 40 (5.3%) comprised our control group. Short sleep duration (< 5 h) was reported by 41.8%. Overall 85.2% had deployed, with 58.1% having one or more comorbid diagnoses. Characteristics associated with moderate-to-severe OSA were age (adjusted odds ratio [OR], 1.03 [95% confidence interval {CI}, 1.0–1.05], sex (male) (adjusted OR, 19.97 [95% CI, 2.66–150.05], anxiety (adjusted OR, 0.58 [95% CI, 0.34–0.99]), and body mass index, BMI (adjusted OR 1.19 [95% CI, 1.13–1.25]; for insomnia, characteristics included PTSD (adjusted OR, 2.12 [95% CI, 1.31–3.44]), pain syndromes (adjusted OR, 1.48 [95%CI, 1.01–2.12]), sex (female) (adjusted OR, 0.22 [95% CI, 0.12–0.41]) and lower BMI (adjusted OR, 0.91 [95% CI, 0.87, 0.95]). Conclusions: Service-related illnesses are prevalent in military personnel who undergo polysomnography with significant associations between PTSD, pain syndromes, and insomnia. Despite having sleep disorders, almost half reported short sleep duration

  12. Sleep disorders and associated medical comorbidities in active duty military personnel.

    PubMed

    Mysliwiec, Vincent; McGraw, Leigh; Pierce, Roslyn; Smith, Patrick; Trapp, Brandon; Roth, Bernard J

    2013-02-01

    Describe the prevalence of sleep disorders in military personnel referred for polysomnography and identify relationships between demographic characteristics, comorbid diagnoses, and specific sleep disorders. Retrospective cross-sectional study. Military medical treatment facility. Active duty military personnel with diagnostic polysomnogram in 2010. Primary sleep disorder rendered by review of polysomnogram and medical record by a board certified sleep medicine physician. Demographic characteristics and conditions of posttraumatic stress disorder (PTSD), mild traumatic brain injury (mTBI), anxiety, depression, and pain syndromes determined by medical record review. Primary sleep diagnoses (n = 725) included: mild obstructive sleep apnea (OSA), 207 (27.2%); insomnia, 188 (24.7%); moderate-to-severe OSA, 183 (24.0 %); and paradoxical insomnia,39 (5.1%); behaviorally induced insufficient sleep syndrome, 68 (8.9%) and snoring, 40 (5.3%) comprised our control group. Short sleep duration (< 5 h) was reported by 41.8%. Overall 85.2% had deployed, with 58.1% having one or more comorbid diagnoses. Characteristics associated with moderate-to-severe OSA were age (adjusted odds ratio [OR], 1.03 [95% confidence interval {CI}, 1.0-1.05], sex (male) (adjusted OR, 19.97 [95% CI, 2.66-150.05], anxiety (adjusted OR, 0.58 [95% CI, 0.34-0.99]), and body mass index, BMI (adjusted OR 1.19 [95% CI, 1.13-1.25]; for insomnia, characteristics included PTSD (adjusted OR, 2.12 [95% CI, 1.31-3.44]), pain syndromes (adjusted OR, 1.48 [95%CI, 1.01-2.12]), sex (female) (adjusted OR, 0.22 [95% CI, 0.12-0.41]) and lower BMI (adjusted OR, 0.91 [95% CI, 0.87, 0.95]). Service-related illnesses are prevalent in military personnel who undergo polysomnography with significant associations between PTSD, pain syndromes, and insomnia. Despite having sleep disorders, almost half reported short sleep duration. Multidisciplinary assessment and treatment of military personnel with sleep disorders and service

  13. 5 CFR 300.706 - Office of Personnel Management adjudication.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 5 Administrative Personnel 1 2011-01-01 2011-01-01 false Office of Personnel Management adjudication. 300.706 Section 300.706 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE... Service Law § 300.706 Office of Personnel Management adjudication. (a) OPM will determine whether failure...

  14. 5 CFR 300.706 - Office of Personnel Management adjudication.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 5 Administrative Personnel 1 2014-01-01 2014-01-01 false Office of Personnel Management adjudication. 300.706 Section 300.706 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE... Service Law § 300.706 Office of Personnel Management adjudication. (a) OPM will determine whether failure...

  15. Personnel Preparation.

    ERIC Educational Resources Information Center

    Fair, George, Ed.; Stodden, Robert, Ed.

    1981-01-01

    Three articles comprise a section on personnel preparation in vocational education. Articles deal with two inservice programs in career/vocational education for the handicapped and a project to train paraprofessionals to assist special educators in vocational education. (CL)

  16. Personnel Practices for Small Colleges.

    ERIC Educational Resources Information Center

    Bouchard, Ronald A.

    Personnel administration in higher education is the focus of this "hands-on, how-to-do-it" guide that provides fundamental materials for developing and maintaining a sound personnel program. Part One (Employment) examines government regulations, employee recruitment and selection, pre-employment inquiries and screening, post-employment process,…

  17. 21 CFR 820.25 - Personnel.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Personnel. 820.25 Section 820.25 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES QUALITY SYSTEM REGULATION Quality System Requirements § 820.25 Personnel. (a) General. Each manufacturer...

  18. 21 CFR 606.20 - Personnel.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Personnel. 606.20 Section 606.20 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) BIOLOGICS CURRENT GOOD MANUFACTURING PRACTICE FOR BLOOD AND BLOOD COMPONENTS Organization and Personnel § 606.20...

  19. The Economy of Energy Conservation in Educational Facilities. A Report. Revised Edition.

    ERIC Educational Resources Information Center

    Educational Facilities Labs., Inc., New York, NY.

    This is an update of the 1973 edition of a guide for energy conservation in schools. This Educational Facilities Laboratories publication is an information source for teachers, school administrators, school maintenance personnel, school designers, or anyone interested in conserving energy in schools. Topics discussed include: (1) life-cycle…

  20. High-Explosives Applications Facility (HEAF)

    NASA Astrophysics Data System (ADS)

    Morse, J. L.; Weingart, R. C.

    1989-03-01

    This Safety Analysis Report (SAR) reviews the safety and environmental aspects of the High Explosives Applications Facility (HEAF). Topics covered include the site selected for the HEAF, safety design criteria, operations planned within the facility, and the safety and environmental analyses performed on this project to date. Provided in the Summary section is a review of hazards and the analyses, conclusions, and operating limits developed in this SAR. Appendices provide supporting documents relating to this SAR. This SAR is required by the LLNL Health and Safety Manual and DOE Order 5481.1B(2) to document the safety analysis efforts. The SAR was assembled by the Hazards Control Department, B-Division, and HEAF project personnel. This document was reviewed by B Division, the Chemistry Department, the Hazards Control Department, the Laboratory Associate Director for Administration and Operations, and the Associate Directors ultimately responsible for HEAF operations.