Sample records for facility psdf located

  1. Power Systems Development Facility Gasification Test Campaing TC18

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Southern Company Services

    2005-08-31

    In support of technology development to utilize coal for efficient, affordable, and environmentally clean power generation, the Power Systems Development Facility (PSDF) located in Wilsonville, Alabama, routinely demonstrates gasification technologies using various types of coals. The PSDF is an engineering scale demonstration of key features of advanced coal-fired power systems, including a KBR Transport Gasifier, a hot gas particulate control device (PCD), advanced syngas cleanup systems, and high pressure solids handling systems. This report details Test Campaign TC18 of the PSDF gasification process. Test campaign TC18 began on June 23, 2005, and ended on August 22, 2005, with the gasifiermore » train accumulating 1,342 hours of operation using Powder River Basin (PRB) subbituminous coal. Some of the testing conducted included commissioning of a new recycle syngas compressor for gasifier aeration, evaluation of PCD filter elements and failsafes, testing of gas cleanup technologies, and further evaluation of solids handling equipment. At the conclusion of TC18, the PSDF gasification process had been operated for more than 7,750 hours.« less

  2. Soil microbial response to waste potassium silicate drilling fluid.

    PubMed

    Yao, Linjun; Naeth, M Anne; Jobson, Allen

    2015-03-01

    Potassium silicate drilling fluids (PSDF) are a waste product of the oil and gas industry with potential for use in land reclamation. Few studies have examined the influence of PSDF on abundance and composition of soil bacteria and fungi. Soils from three representative locations for PSDF application in Alberta, Canada, with clay loam, loam and sand textures were studied with applications of unused, used once and used twice PSDF. For all three soils, applying ≥40 m3/ha of used PSDF significantly affected the existing soil microbial flora. No microbiota was detected in unused PSDF without soil. Adding used PSDF to soil significantly increased total fungal and aerobic bacterial colony forming units in dilution plate counts, and anaerobic denitrifying bacteria numbers in serial growth experiments. Used PSDF altered bacterial and fungal colony forming unit ratios of all three soils. Copyright © 2015. Published by Elsevier B.V.

  3. Soil and plant response to used potassium silicate drilling fluid application.

    PubMed

    Yao, Linjun; Anne Naeth, M

    2015-10-01

    Use of drilling waste generated from the oil and gas industry for land reclamation has potential to be a practical and economical means to improve soil fertility and to decrease landfills. A four month greenhouse experiment with common barley (Hordeum vulgare L.) on three different textured soils was conducted to determine soil and plant response to incorporated or sprayed potassium silicate drilling fluid (PSDF). Two PSDF types (used once, used twice) were applied at six rates (10, 20, 30, 40, 60, 120m(3)ha(-1)) as twelve PSDF amendments plus a control (non PSDF). Effects of PSDF amendment on plant properties were significant, and varied through physiological growth stages. Barley emergence and below ground biomass were greater with used once than used twice PSDF at the same application rate in clay loam soil. Used twice PSDF at highest rates significantly increased barley above ground biomass relative to the control in loam and sand soil. All PSDF treatments significantly increased available potassium relative to the control in all three soils. Soil electrical conductivity and sodium adsorption ratio increased with PSDF addition, but not to levels detrimental to barley. Soil quality rated fair to poor with PSDF amendments in clay loam, and reduced plant performance at the highest rate, suggesting a threshold beyond which conditions are compromised with PSDF utilization. PSDF application method did not significantly affect plant and soil responses. This initial greenhouse research demonstrates that PSDF has potential as a soil amendment for reclamation, with consideration of soil properties and plant species tolerances to determine PSDF types and rates to be used. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Characteristics of power spectrum density function of EMG during muscle contraction below 30%MVC.

    PubMed

    Roman-Liu, Danuta; Konarska, Maria

    2009-10-01

    The aim of the study was to quantify changes in PSDF frequency bands of the EMG signal and EMG parameters such as MF, MPF and zero crossing, with an increase in the level of muscle contractions in the range from 0.5% to 30% RMS(max) and to determine the frequency bands with the lowest dependency on RMS level so that this could be used in investigating muscle fatigue. Sixteen men, aged from 23 to 33 years old (mean 26.1), who participated in the study performed two force exertion tests. Fragments of EMG which corresponded to the levels of muscle contraction of 0.5%, 1%, 2.5%, 5%, 10%, 15%, 20%, 25%, 30% RMS(max) registered from left and right trapezius pars descendents (TP) and left and right extensor digitorum superficialis (ED) muscles were selected for analysis. The analysis included changes in standard parameters of the EMG signal and changes in PSDF frequency bands, which occurred across muscle contraction levels. To analyze changes in PSDF across the level of muscle contraction, the spectrum was divided into six frequency bandwidths. The analysis of parameters focused on the differences in those parameters between the analyzed muscles, at different levels of muscle contraction. The study revealed that, at muscle contraction levels below 5% RMSmax, contraction level influences standard parameters of the EMG signal and that at such levels of muscle contraction every change in muscle contraction level (recruitment of additional MUs) is reflected in PSDF. The frequency band with the lowest dependency on contraction level was 76-140 Hz for which in both muscles no contraction level effect was detected for contraction levels above 5% RMS(max). The reproducibility of the results was very high, since the observations in of the left and right muscles were almost equal. The other factor, which strongly influences PSDF of the EMG signal, is probably the examined muscle structure (muscle morphology, size, function, subcutaneous layer, cross talk). It seems that low frequency bands up to 25 Hz are especially feasible for type of muscle.

  5. Characteristics of EMG frequency bands in temporomandibullar disorders patients.

    PubMed

    Politti, Fabiano; Casellato, Claudia; Kalytczak, Marcelo Martins; Garcia, Marilia Barbosa Santos; Biasotto-Gonzalez, Daniela Aparecida

    2016-12-01

    The aim of the present study was to determine whether any specific frequency bands of surface electromyographic (sEMG) signals are more susceptible to alterations in patients with temporomandibular disorders (TMD), when compared with healthy subjects. Twenty-seven healthy adults (19 women and eight men; mean age: 23±6.68years) and 27 TMD patients (20 women and seven men; mean age: 24±5.89years) voluntarily participated in the experiment. sEMG data were recorded from the right and left masseter muscles (RM and LM) and the right and left anterior temporalis muscles (RT and LT) as the participants performed tests of chewing (CHW) and maximal clenching effort (MCE). Frequency domain analysis of the sEMG signal was used to analyze differences between TMD patients and healthy subjects in relation to the Power Spectral Density Function (PSDF). The analysis focused on the median frequency (MDF) of the sEMG signal and PSDF frequency bands after the EMG spectrum was divided into twenty-five frequency band of 20Hz each. The Mann-Whitney test was used to compare MDF between TMD patients and healthy subjects and the frequency bands were analyzed using three-way ANOVA with three factors: frequency band, muscle and group. The results of the analysis confirmed that the median frequency values in TMD patients were significantly higher (p<0.05) than those recorded for healthy subjects in the two experimental conditions (MCE and CHW), for all of the muscles assessed (RM, LM, RT and LT). In addition, frequency content between 20 and 100Hz of the normalized PSDF range was significantly lower (p<0.05) in TMD patients than in healthy. This study contributes to quantitatively identify TMD dysfunctions, by non-invasive sEMGs; this assessment is clinically important and still lacking nowadays. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Working together--primary care doctors' and nurses' attitudes to collaboration.

    PubMed

    Hansson, Anders; Arvemo, Tobias; Marklund, Bertil; Gedda, Birgitta; Mattsson, Bengt

    2010-02-01

    Multidisciplinary teamwork is recommended for various disorders and it has been suggested that it is a way to meet the new challenges and demands facing general practitioners (GPs) in modern society. Attempts to introduce the method in primary care have failed partly due to GPs' unwillingness to participate. The aim of this study was to measure attitudes towards collaboration among GPs and district nurses (DN) and to investigate whether there is a correlation between a positive attitude toward collaboration and high self-esteem in the professional role. The Jefferson Scale of Attitudes toward Physician Nurse Collaboration and the Professional Self-Description Form (PSDF) was used to study a cohort of 600 GPs and DNs in Västra Götaland region. The purpose was to map differences and correlations of attitude between DNs and GPs, between male and female GPs, and between older and younger DNs and GPs. Four hundred and one answers were received. DNs (mean 51.7) were significantly more positive about collaboration than GPs (mean 49.4). There was no difference between younger and older, male and female GPs. DNs scored higher on the PSDF-scale than GPs. DNs were slightly more positive about collaboration than GPs. A positive attitude towards collaboration did not seem to be a part of the GPs' professional role to the same extent as it is for DNs. Professional norms seem to have more influence on attitudes than do gender roles. DNs seem more confident in their profession than GPs.

  7. Three-dimensional distribution of random velocity inhomogeneities at the Nankai trough seismogenic zone

    NASA Astrophysics Data System (ADS)

    Takahashi, T.; Obana, K.; Yamamoto, Y.; Nakanishi, A.; Kaiho, Y.; Kodaira, S.; Kaneda, Y.

    2012-12-01

    The Nankai trough in southwestern Japan is a convergent margin where the Philippine sea plate is subducted beneath the Eurasian plate. There are major faults segments of huge earthquakes that are called Tokai, Tonankai and Nankai earthquakes. According to the earthquake occurrence history over the past hundreds years, we must expect various rupture patters such as simultaneous or nearly continuous ruptures of plural fault segments. Japan Agency for Marine-Earth Science and Technology (JAMSTEC) conducted seismic surveys at Nankai trough in order to clarify mutual relations between seismic structures and fault segments, as a part of "Research concerning Interaction Between the Tokai, Tonankai and Nankai Earthquakes" funded by Ministry of Education, Culture, Sports, Science and Technology, Japan. This study evaluated the spatial distribution of random velocity inhomogeneities from Hyuga-nada to Kii-channel by using velocity seismograms of small and moderate sized earthquakes. Random velocity inhomogeneities are estimated by the peak delay time analysis of S-wave envelopes (e.g., Takahashi et al. 2009). Peak delay time is defined as the time lag from the S-wave onset to its maximal amplitude arrival. This quantity mainly reflects the accumulated multiple forward scattering effect due to random inhomogeneities, and is quite insensitive to the inelastic attenuation. Peak delay times are measured from the rms envelopes of horizontal components at 4-8Hz, 8-16Hz and 16-32Hz. This study used the velocity seismograms that are recorded by 495 ocean bottom seismographs and 378 onshore seismic stations. Onshore stations are composed of the F-net and Hi-net stations that are maintained by National Research Institute for Earth Science and Disaster Prevention (NIED) of Japan. It is assumed that the random inhomogeneities are represented by the von Karman type PSDF. Preliminary result of inversion analysis shows that spectral gradient of PSDF (i.e., scale dependence of inhomogeneities) are the same overt the Nankai trough, but random inhomogeneities at smaller wavenumber shows anomalously large values at the southwestern part of Hyuga-nada and Kii-channel. Anomaly at Hyuga-nada is almost located at the subducted Kyushu Palau ridge. Similar random inhomogeneities were imaged near the remnant of ancient arc in the northern Izu-Bonin arc (Takahashi et al. 2011). We speculate these random inhomogeneities reflect the remnant of ancient volcanic activities. These results imply that random inhomogeneities at Kii-channel are possibly related to the subducted seamount, and that random inhomogeneities are useful to discuss the medium characteristics in subduction zone.

  8. Spatial distribution of random velocity inhomogeneities in the western part of Nankai subduction zone

    NASA Astrophysics Data System (ADS)

    Takahashi, T.; Obana, K.; Yamamoto, Y.; Nakanishi, A.; Kodaira, S.; Kaneda, Y.

    2011-12-01

    In the Nankai trough, there are three seismogenic zones of megathrust earthquakes (Tokai, Tonankai and Nankai earthquakes). Lithospheric structures in and around these seismogenic zones are important for the studies on mutual interactions and synchronization of their fault ruptures. Recent studies on seismic wave scattering at high frequencies (>1Hz) make it possible to estimate 3D distributions of random inhomogeneities (or scattering coefficient) in the lithosphere, and clarified that random inhomogeneity is one of the important medium properties related to microseismicity and damaged structure near the fault zone [Asano & Hasegawa, 2004; Takahashi et al. 2009]. This study estimates the spatial distribution of the power spectral density function (PSDF) of random inhomogeneities the western part of Nankai subduction zone, and examines the relations with crustal velocity structure and seismic activity. Seismic waveform data used in this study are those recorded at seismic stations of Hi-net & F-net operated by NIED, and 160 ocean bottom seismographs (OBSs) deployed at Hyuga-nada region from Dec. 2008 to Jan. 2009. This OBS observation was conducted by JAMSTEC as a part of "Research concerning Interaction Between the Tokai, Tonankai and Nankai Earthquakes" funded by Ministry of Education, Culture, Sports, Science and Technology, Japan. Spatial distribution of random inhomogeneities is estimated by the inversion analysis of the peak delay time of small earthquakes [Takahashi et al. 2009], where the peak delay time is defined as the time lag from the S-wave onset to its maximal amplitude arrival. We assumed the von Karman type functional form for the PSDF. Peak delay times are measured from root mean squared envelopes at 4-8Hz, 8-16Hz and 16-32Hz. Inversion result can be summarized as follows. Random inhomogeneities beneath the Quaternary volcanoes are characterized by strong inhomogeneities at small spatial scale (~ a few hundreds meter) and weak spectral gradient. Those in the Hyuga-nada region are characterized by the strong inhomogeneities at large spatial wavelength and steep spectral gradient. Random inhomogeneities in the Hyuga-nada region are similar with those in the frontal arc high in northern Izu-Bonin arc, which is thought to be a remnant arc that is presently inactive [Takahashi et al. 2011]. This coincidence implies the existence of subducted Kyushu-Palau ridge in this anomaly of random inhomogeneities, which is also suggested by the seismic refraction survey in this region [Nakanishi et al. 2010 AGU Fall Mtg.]. Source rupture areas of large earthquakes (M>6) in Hyuga-nada regions tend to locate around this anomaly of inhomogeneities. We may say that this anomalously inhomogeneous region is a structural factor affecting the seismic activity in Hyuga-nada region.

  9. ENGINEERING DEVELOPMENT OF COAL-FIRED HIGH-PERFORMANCE POWER SYSTEMS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Unknown

    1999-02-01

    A High Performance Power System (HIPPS) is being developed. This system is a coal-fired, combined cycle plant with indirect heating of gas turbine air. Foster Wheeler Development Corporation and a team consisting of Foster Wheeler Energy Corporation, Bechtel Corporation, University of Tennessee Space Institute and Westinghouse Electric Corporation are developing this system. In Phase 1 of the project, a conceptual design of a commercial plant was developed. Technical and economic analyses indicated that the plant would meet the goals of the project which include a 47 percent efficiency (HHV) and a 10 percent lower cost of electricity than an equivalentmore » size PC plant. The concept uses a pyrolysis process to convert coal into fuel gas and char. The char is fired in a High Temperature Advanced Furnace (HITAF). The HITAF is a pulverized fuel-fired boiler/air heater where steam is generated and gas turbine air is indirectly heated. The fuel gas generated in the pyrolyzer is then used to heat the gas turbine air further before it enters the gas turbine. The project is currently in Phase 2 which includes engineering analysis, laboratory testing and pilot plant testing. Research and development is being done on the HIPPS systems that are not commercial or being developed on other projects. Pilot plant testing of the pyrolyzer subsystem and the char combustion subsystem are being done separately, and after each experimental program has been completed, a larger scale pyrolyzer will be tested at the Power Systems Development Facility (PSDF) in Wilsonville, AL. The facility is equipped with a gas turbine and a topping combustor, and as such, will provide an opportunity to evaluate integrated pyrolyzer and turbine operation. This report addresses the areas of technical progress for this quarter. A general arrangement drawing of the char transfer system was forwarded to SCS for their review. Structural steel drawings were used to generate a three-dimensional model of the char transfer system including all pressure vessels and major piping components. Experimental testing at the Combustion and Environmental Test Facility continued during this quarter. Performance of the char burner, as benchmarked by flame stability and low NOx, has been exceptional. The burner was operated successfully both without natural gas and supplemental pulverized coal.« less

  10. 30 CFR 71.401 - Location of facilities.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Location of facilities. 71.401 Section 71.401... Location of facilities. Bathhouses, change rooms, and sanitary flush toilet facilities shall be in a location convenient for the use of the miners. Where these facilities are designed to serve more than one...

  11. 30 CFR 71.401 - Location of facilities.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Bathing Facilities, Change Rooms, and Sanitary Flush Toilet Facilities at Surface Coal Mines § 71.401 Location of facilities. Bathhouses, change rooms, and sanitary flush toilet facilities shall be in a... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Location of facilities. 71.401 Section 71.401...

  12. 30 CFR 71.401 - Location of facilities.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Bathing Facilities, Change Rooms, and Sanitary Flush Toilet Facilities at Surface Coal Mines § 71.401 Location of facilities. Bathhouses, change rooms, and sanitary flush toilet facilities shall be in a... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Location of facilities. 71.401 Section 71.401...

  13. 30 CFR 71.401 - Location of facilities.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Bathing Facilities, Change Rooms, and Sanitary Flush Toilet Facilities at Surface Coal Mines § 71.401 Location of facilities. Bathhouses, change rooms, and sanitary flush toilet facilities shall be in a... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Location of facilities. 71.401 Section 71.401...

  14. 30 CFR 71.401 - Location of facilities.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Bathing Facilities, Change Rooms, and Sanitary Flush Toilet Facilities at Surface Coal Mines § 71.401 Location of facilities. Bathhouses, change rooms, and sanitary flush toilet facilities shall be in a... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Location of facilities. 71.401 Section 71.401...

  15. Weather radar equation and a receiver calibration based on a slice approach

    NASA Astrophysics Data System (ADS)

    Yurchak, B. S.

    2012-12-01

    Two circumstances are essential when exploiting radar measurement of precipitation. The first circumstance is a correct physical-mathematical model linking parameters of a rainfall microstructure with a magnitude of a return signal (the weather radar equation (WRE)). The second is a precise measurement of received power that is fitted by a calibration of radar receiver. WRE for the spatially extended geophysical target (SEGT), such as cloud or rain, has been derived based on "slice" approach [1]. In this approach, the particles located close to the wavefront of the radar illumination are assumed to produce backscatter that is mainly coherent. This approach allows the contribution of the microphysical parameters of the scattering media to the radar cross section to be more comprehensive than the model based on the incoherent approach (e.g., Probert-Jones equation (PJE)). In the particular case, when the particle number fluctuations within slices pertain the Poisson law, the WRE derived is transformed to PJE. When Poisson index (standard deviation / mean number of particles) of a slice deviates from 1, the deviation of return power estimated by PJE from the actual value varies from +8 dB to - 12 dB. In general, the backscatter depends on mean, variance and third moment of the particle size distribution function (PSDF). The incoherent approach assumes only dependence on the sixth moment of PSDF (radar reflectivity Z). Additional difference from the classical estimate can be caused by a correlation between slice field reflectivity [2]. Overall, the deviation in particle statistics of a slice from the Poisson law is one of main physical factors that contribute to errors in radar precipitation measurements based on Z-conception. One of the components of calibration error is caused by difference between processing by weather radar receiver of the calibration pulse, and actual return signal from SEGT. A receiver with non uniform amplitude-frequency response (AFR) processes these signals with the same input power but with different radio-frequency spectrums (RFS). This causes different output magnitude due to different distortion experienced while RFS passing through a receiver filter. To assess the calibration error, RFS of signals from SEGT has been studied including theoretical, experimental and simulation stages [3]. It is shown that the return signal carrier wave is phase modulated due to overlapping of replicas of RF-probing pulse reflected from SEGT's slices. The RFSs depends on the phase statistics of the carrier wave and on RFS of the probing pulse. The bandwidth of SEGT's RFS is not greater than that of the probing pulse. Typical phase correlation interval was found to be around the same as that of the probing pulse duration. Application of a long calibration signal (proportional to SEGT extension) causes the error up to -1 dB for conventional radar with matched filter. To eliminate the calibration error, a power estimate of individual return waveform should be corrected with the transformation loss coefficient calculated based on RFS and AFR parameters. To embrace with calibration the high and low frequency parts of a receiver, the calibration should be performed with a long pulse. That long pulse is composed from adjoining replicas of a probe pulse with random initial phases and having the same magnitude governed by the power of probe pulse.

  16. Periodic components of hand acceleration/deceleration impulses during telemanipulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Draper, J.V.; Handel, S.

    1994-01-01

    Responsiveness is the ability of a telemanipulator to recreate user trajectories and impedance in time and space. For trajectory production, a key determinant of responsiveness is the ability of the system to accept user inputs, which are forces on the master handle generated by user hand acceleration/deceleration (a/d) impulses, and translate them into slave arm acceleration/deceleration. This paper presents observations of master controller a/d impulses during completion of a simple target acquisition task. Power spectral density functions (PSDF`s) calculated from hand controller a/d impulses were used to assess impulse waveform. The relative contributions of frequency intervals ranging up to 25more » Hz for three spatially different versions of the task were used to determine which frequencies were most important. The highest relative power was observed in frequencies between 1 Hz and 6 Hz. The key frequencies related to task difficulty were in the range from 2 Hz to 8 Hz. the results provide clues to the source of the performance inhibition.« less

  17. 30 CFR 75.1712-2 - Location of surface facilities.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1712-2 Location of surface facilities. Bathhouses, change rooms, and sanitary toilet facilities shall be in a location... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Location of surface facilities. 75.1712-2...

  18. 30 CFR 75.1712-2 - Location of surface facilities.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1712-2 Location of surface facilities. Bathhouses, change rooms, and sanitary toilet facilities shall be in a location... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Location of surface facilities. 75.1712-2...

  19. 30 CFR 75.1712-2 - Location of surface facilities.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1712-2 Location of surface facilities. Bathhouses, change rooms, and sanitary toilet facilities shall be in a location... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Location of surface facilities. 75.1712-2...

  20. 30 CFR 75.1712-2 - Location of surface facilities.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1712-2 Location of surface facilities. Bathhouses, change rooms, and sanitary toilet facilities shall be in a location... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Location of surface facilities. 75.1712-2...

  1. 30 CFR 75.1712-2 - Location of surface facilities.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Location of surface facilities. 75.1712-2... SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1712-2 Location of surface facilities. Bathhouses, change rooms, and sanitary toilet facilities shall be in a location...

  2. 14 CFR 21.43 - Location of manufacturing facilities.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Location of manufacturing facilities. 21.43... CERTIFICATION PROCEDURES FOR PRODUCTS AND PARTS Type Certificates § 21.43 Location of manufacturing facilities... location of the manufacturer's facilities places no undue burden on the FAA in administering applicable...

  3. 30 CFR 254.50 - Spill response plans for facilities located in State waters seaward of the coast line.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... ENVIRONMENTAL ENFORCEMENT, DEPARTMENT OF THE INTERIOR OFFSHORE OIL-SPILL RESPONSE REQUIREMENTS FOR FACILITIES LOCATED SEAWARD OF THE COAST LINE Oil-Spill Response Requirements for Facilities Located in State Waters... 30 Mineral Resources 2 2012-07-01 2012-07-01 false Spill response plans for facilities located in...

  4. 30 CFR 254.50 - Spill response plans for facilities located in State waters seaward of the coast line.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... ENVIRONMENTAL ENFORCEMENT, DEPARTMENT OF THE INTERIOR OFFSHORE OIL-SPILL RESPONSE REQUIREMENTS FOR FACILITIES LOCATED SEAWARD OF THE COAST LINE Oil-Spill Response Requirements for Facilities Located in State Waters... 30 Mineral Resources 2 2013-07-01 2013-07-01 false Spill response plans for facilities located in...

  5. 30 CFR 254.50 - Spill response plans for facilities located in State waters seaward of the coast line.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... SERVICE, DEPARTMENT OF THE INTERIOR OFFSHORE OIL-SPILL RESPONSE REQUIREMENTS FOR FACILITIES LOCATED SEAWARD OF THE COAST LINE Oil-Spill Response Requirements for Facilities Located in State Waters Seaward... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Spill response plans for facilities located in...

  6. 30 CFR 254.50 - Spill response plans for facilities located in State waters seaward of the coast line.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... ENVIRONMENTAL ENFORCEMENT, DEPARTMENT OF THE INTERIOR OFFSHORE OIL-SPILL RESPONSE REQUIREMENTS FOR FACILITIES LOCATED SEAWARD OF THE COAST LINE Oil-Spill Response Requirements for Facilities Located in State Waters... 30 Mineral Resources 2 2014-07-01 2014-07-01 false Spill response plans for facilities located in...

  7. 7 CFR 1735.91 - Location of facilities.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 11 2010-01-01 2010-01-01 false Location of facilities. 1735.91 Section 1735.91 Agriculture Regulations of the Department of Agriculture (Continued) RURAL UTILITIES SERVICE, DEPARTMENT OF... All Acquisitions and Mergers § 1735.91 Location of facilities. Telephone facilities to be acquired...

  8. 7 CFR 1738.12 - Location of facilities.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 11 2010-01-01 2010-01-01 false Location of facilities. 1738.12 Section 1738.12 Agriculture Regulations of the Department of Agriculture (Continued) RURAL UTILITIES SERVICE, DEPARTMENT OF... Location of facilities. RUS will make broadband loans for facilities which RUS determines are necessary to...

  9. 76 FR 60390 - Irradiation Treatment; Location of Facilities in the Southern United States

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-29

    ... [Docket No. APHIS-2009-0100] RIN 0579-AD35 Irradiation Treatment; Location of Facilities in the Southern... irradiation treatment facilities in the Southern States of the United States. This action would allow irradiation facilities to be located anywhere in these States, subject to approval, rather than only in the...

  10. 30 CFR 254.50 - Spill response plans for facilities located in State waters seaward of the coast line.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... MANAGEMENT, REGULATION, AND ENFORCEMENT, DEPARTMENT OF THE INTERIOR OFFSHORE OIL-SPILL RESPONSE REQUIREMENTS FOR FACILITIES LOCATED SEAWARD OF THE COAST LINE Oil-Spill Response Requirements for Facilities... 30 Mineral Resources 2 2011-07-01 2011-07-01 false Spill response plans for facilities located in...

  11. TRI Reporting for Facilities Located in Indian Country

    EPA Pesticide Factsheets

    A final rule requires facilities that meet TRI reporting requirements and that are located in Indian country to submit TRI forms to EPA and the appropriate tribe, rather than to the state in which the facility is geographically located.

  12. 18 CFR 292.208 - Special requirements for hydroelectric small power production facilities located at a new dam or...

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... for hydroelectric small power production facilities located at a new dam or diversion. 292.208 Section... requirements for hydroelectric small power production facilities located at a new dam or diversion. (a) A hydroelectric small power production facility that impounds or diverts the water of a natural watercourse by...

  13. 18 CFR 292.208 - Special requirements for hydroelectric small power production facilities located at a new dam or...

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... for hydroelectric small power production facilities located at a new dam or diversion. 292.208 Section... requirements for hydroelectric small power production facilities located at a new dam or diversion. (a) A hydroelectric small power production facility that impounds or diverts the water of a natural watercourse by...

  14. 18 CFR 292.208 - Special requirements for hydroelectric small power production facilities located at a new dam or...

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... for hydroelectric small power production facilities located at a new dam or diversion. 292.208 Section... requirements for hydroelectric small power production facilities located at a new dam or diversion. (a) A hydroelectric small power production facility that impounds or diverts the water of a natural watercourse by...

  15. FEDERAL FACILITIES IN EPA REGION 6

    EPA Science Inventory

    Locations of federal facilities in EPA Region 6. Facilities from the Corps of Engineers, Veterans Administration, Army, Navy, Air National Guard, etc. are included. This is not a complete set of facilities. The facilities included are only those with value added locations used in...

  16. Comparison of optimized algorithms in facility location allocation problems with different distance measures

    NASA Astrophysics Data System (ADS)

    Kumar, Rakesh; Chandrawat, Rajesh Kumar; Garg, B. P.; Joshi, Varun

    2017-07-01

    Opening the new firm or branch with desired execution is very relevant to facility location problem. Along the lines to locate the new ambulances and firehouses, the government desires to minimize average response time for emergencies from all residents of cities. So finding the best location is biggest challenge in day to day life. These type of problems were named as facility location problems. A lot of algorithms have been developed to handle these problems. In this paper, we review five algorithms that were applied to facility location problems. The significance of clustering in facility location problems is also presented. First we compare Fuzzy c-means clustering (FCM) algorithm with alternating heuristic (AH) algorithm, then with Particle Swarm Optimization (PSO) algorithms using different type of distance function. The data was clustered with the help of FCM and then we apply median model and min-max problem model on that data. After finding optimized locations using these algorithms we find the distance from optimized location point to the demanded point with different distance techniques and compare the results. At last, we design a general example to validate the feasibility of the five algorithms for facilities location optimization, and authenticate the advantages and drawbacks of them.

  17. 18 CFR 292.209 - Exceptions from requirements for hydroelectric small power production facilities located at a new...

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... requirements for hydroelectric small power production facilities located at a new dam or diversion. 292.209... Exceptions from requirements for hydroelectric small power production facilities located at a new dam or... license or exemption is filed for a project located at a Government dam, as defined in section 3(10) of...

  18. 18 CFR 292.209 - Exceptions from requirements for hydroelectric small power production facilities located at a new...

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... requirements for hydroelectric small power production facilities located at a new dam or diversion. 292.209... Exceptions from requirements for hydroelectric small power production facilities located at a new dam or... license or exemption is filed for a project located at a Government dam, as defined in section 3(10) of...

  19. Hazardous Waste Cleanup: Frontier Chemical Waste Process Incorporated – Royal Avenue Site in Niagara Falls, New York

    EPA Pesticide Factsheets

    Frontier Chemical Waste Process facility is located in a heavy industrial/commercial area. Several large industrial facilities surround the facility. The closest residential area is located about ½ mile west and the closest off-site building is located 300

  20. 14 CFR 145.105 - Change of location, housing, or facilities.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Change of location, housing, or facilities. 145.105 Section 145.105 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF..., Materials, and Data § 145.105 Change of location, housing, or facilities. (a) A certificated repair station...

  1. 14 CFR 145.105 - Change of location, housing, or facilities.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Change of location, housing, or facilities. 145.105 Section 145.105 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF..., Materials, and Data § 145.105 Change of location, housing, or facilities. (a) A certificated repair station...

  2. 14 CFR 145.105 - Change of location, housing, or facilities.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Change of location, housing, or facilities. 145.105 Section 145.105 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF..., Materials, and Data § 145.105 Change of location, housing, or facilities. (a) A certificated repair station...

  3. 14 CFR 145.105 - Change of location, housing, or facilities.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Change of location, housing, or facilities. 145.105 Section 145.105 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF..., Materials, and Data § 145.105 Change of location, housing, or facilities. (a) A certificated repair station...

  4. 14 CFR 145.105 - Change of location, housing, or facilities.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Change of location, housing, or facilities. 145.105 Section 145.105 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF..., Materials, and Data § 145.105 Change of location, housing, or facilities. (a) A certificated repair station...

  5. 77 FR 33479 - Information Collection Activities: Oil-Spill Response Requirements for Facilities Located Seaward...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-06

    ...-0010; OMB Control Number 1014-0007] Information Collection Activities: Oil-Spill Response Requirements... regulations under Part 254, ``Oil-Spill Response Requirements for Facilities Located Seaward of the Coast Line... 254, Oil-Spill Response Requirements for Facilities Located Seaward of the Coast Line. OMB Control...

  6. A reliable facility location design model with site-dependent disruption in the imperfect information context

    PubMed Central

    Yun, Lifen; Wang, Xifu; Fan, Hongqiang; Li, Xiaopeng

    2017-01-01

    This paper proposes a reliable facility location design model under imperfect information with site-dependent disruptions; i.e., each facility is subject to a unique disruption probability that varies across the space. In the imperfect information contexts, customers adopt a realistic “trial-and-error” strategy to visit facilities; i.e., they visit a number of pre-assigned facilities sequentially until they arrive at the first operational facility or give up looking for the service. This proposed model aims to balance initial facility investment and expected long-term operational cost by finding the optimal facility locations. A nonlinear integer programming model is proposed to describe this problem. We apply a linearization technique to reduce the difficulty of solving the proposed model. A number of problem instances are studied to illustrate the performance of the proposed model. The results indicate that our proposed model can reveal a number of interesting insights into the facility location design with site-dependent disruptions, including the benefit of backup facilities and system robustness against variation of the loss-of-service penalty. PMID:28486564

  7. 30 CFR 75.1712-8 - Application for waiver of location requirements for underground sanitary facilities.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... for underground sanitary facilities. 75.1712-8 Section 75.1712-8 Mineral Resources MINE SAFETY AND...-UNDERGROUND COAL MINES Miscellaneous § 75.1712-8 Application for waiver of location requirements for underground sanitary facilities. Applications for waivers of the location requirements of § 75.1712-6 shall be...

  8. 30 CFR 75.1712-8 - Application for waiver of location requirements for underground sanitary facilities.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... for underground sanitary facilities. 75.1712-8 Section 75.1712-8 Mineral Resources MINE SAFETY AND...-UNDERGROUND COAL MINES Miscellaneous § 75.1712-8 Application for waiver of location requirements for underground sanitary facilities. Applications for waivers of the location requirements of § 75.1712-6 shall be...

  9. 30 CFR 75.1712-8 - Application for waiver of location requirements for underground sanitary facilities.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... for underground sanitary facilities. 75.1712-8 Section 75.1712-8 Mineral Resources MINE SAFETY AND...-UNDERGROUND COAL MINES Miscellaneous § 75.1712-8 Application for waiver of location requirements for underground sanitary facilities. Applications for waivers of the location requirements of § 75.1712-6 shall be...

  10. 30 CFR 75.1712-8 - Application for waiver of location requirements for underground sanitary facilities.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... for underground sanitary facilities. 75.1712-8 Section 75.1712-8 Mineral Resources MINE SAFETY AND...-UNDERGROUND COAL MINES Miscellaneous § 75.1712-8 Application for waiver of location requirements for underground sanitary facilities. Applications for waivers of the location requirements of § 75.1712-6 shall be...

  11. 30 CFR 75.1712-8 - Application for waiver of location requirements for underground sanitary facilities.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... for underground sanitary facilities. 75.1712-8 Section 75.1712-8 Mineral Resources MINE SAFETY AND...-UNDERGROUND COAL MINES Miscellaneous § 75.1712-8 Application for waiver of location requirements for underground sanitary facilities. Applications for waivers of the location requirements of § 75.1712-6 shall be...

  12. 18 CFR 292.209 - Exceptions from requirements for hydroelectric small power production facilities located at a new...

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... requirements for hydroelectric small power production facilities located at a new dam or diversion. 292.209... Exceptions from requirements for hydroelectric small power production facilities located at a new dam or... the Federal Power Act, at which non-Federal hydroelectric development is permissible; or (2) An...

  13. 18 CFR 292.209 - Exceptions from requirements for hydroelectric small power production facilities located at a new...

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... requirements for hydroelectric small power production facilities located at a new dam or diversion. 292.209... Exceptions from requirements for hydroelectric small power production facilities located at a new dam or... the Federal Power Act, at which non-Federal hydroelectric development is permissible; or (2) An...

  14. 18 CFR 292.209 - Exceptions from requirements for hydroelectric small power production facilities located at a new...

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... requirements for hydroelectric small power production facilities located at a new dam or diversion. 292.209... Exceptions from requirements for hydroelectric small power production facilities located at a new dam or... the Federal Power Act, at which non-Federal hydroelectric development is permissible; or (2) An...

  15. Ant colony optimization for solving university facility layout problem

    NASA Astrophysics Data System (ADS)

    Mohd Jani, Nurul Hafiza; Mohd Radzi, Nor Haizan; Ngadiman, Mohd Salihin

    2013-04-01

    Quadratic Assignment Problems (QAP) is classified as the NP hard problem. It has been used to model a lot of problem in several areas such as operational research, combinatorial data analysis and also parallel and distributed computing, optimization problem such as graph portioning and Travel Salesman Problem (TSP). In the literature, researcher use exact algorithm, heuristics algorithm and metaheuristic approaches to solve QAP problem. QAP is largely applied in facility layout problem (FLP). In this paper we used QAP to model university facility layout problem. There are 8 facilities that need to be assigned to 8 locations. Hence we have modeled a QAP problem with n ≤ 10 and developed an Ant Colony Optimization (ACO) algorithm to solve the university facility layout problem. The objective is to assign n facilities to n locations such that the minimum product of flows and distances is obtained. Flow is the movement from one to another facility, whereas distance is the distance between one locations of a facility to other facilities locations. The objective of the QAP is to obtain minimum total walking (flow) of lecturers from one destination to another (distance).

  16. 47 CFR 95.1107 - Authorized locations.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PERSONAL RADIO... care facility provided the facility is located anywhere a CB station operation is permitted under § 95... associated with a health care facility. ...

  17. Minimizing Security Forces Response Times Through the Use of Facility Location Methodologies

    DTIC Science & Technology

    2005-03-01

    etc. In his book Network and Discrete Location: Models, Algorithms, and Applications author Mark S. Daskin provides a comprehensive introduction to...the art and science of locating facilities. ( Daskin , 1995) The book espouses to be a hands-on guide to using and developing facility location models...method used in this research is from Daskin (1995). The formulation presented by Daskin includes a multiplicative weighting factor for the amount

  18. Environmental justice: frequency and severity of US chemical industry accidents and the socioeconomic status of surrounding communities.

    PubMed

    Elliott, M R; Wang, Y; Lowe, R A; Kleindorfer, P R

    2004-01-01

    The Clean Air Act Amendments of 1990 requires that chemical facilities in the US with specified quantities of certain toxic or flammable chemicals file a five year history of accidents. This study considers the relation between the reported accidents and surrounding community characteristics. This study is a retrospective analysis of the association between the demographics of counties in which facilities are located and the risk of accidental chemical release and resulting injuries at those facilities. The "location risk" (the risk that a facility having large volumes of hazardous chemicals is located in a community) and "operations risk" (the risk of an accident itself) are investigated. 1994-2000 accident history data from 15 083 US industrial facilities using one or more of 140 flammable or toxic substances above a threshold level. Demographic makeup of 2333 counties surrounding these facilities was determined from the 1990 US census. Larger and more chemical intensive facilities tend to be located in counties with larger African-American populations and in counties with both higher median incomes and high levels of income inequality. Even after adjusting for location risk there is greater risk of accidents for facilities in heavily African-American counties (OR of accident = 1.9, 95% CI = 1.5 to 2.4). Further research and policy interventions are required to reduce the probability of locating facilities in an inequitable fashion, as well as health surveillance, and regulatory monitoring and enforcement activities to ensure that hazardous facilities in minority communities prepare and prevent accidental chemical releases to the same standards as elsewhere.

  19. 30 CFR 254.54 - Spill prevention for facilities located in State waters seaward of the coast line.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... ENVIRONMENTAL ENFORCEMENT, DEPARTMENT OF THE INTERIOR OFFSHORE OIL-SPILL RESPONSE REQUIREMENTS FOR FACILITIES LOCATED SEAWARD OF THE COAST LINE Oil-Spill Response Requirements for Facilities Located in State Waters... of the steps you are taking to prevent spills of oil or mitigate a substantial threat of such a...

  20. 30 CFR 254.54 - Spill prevention for facilities located in State waters seaward of the coast line.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... SERVICE, DEPARTMENT OF THE INTERIOR OFFSHORE OIL-SPILL RESPONSE REQUIREMENTS FOR FACILITIES LOCATED SEAWARD OF THE COAST LINE Oil-Spill Response Requirements for Facilities Located in State Waters Seaward... of the steps you are taking to prevent spills of oil or mitigate a substantial threat of such a...

  1. 30 CFR 254.54 - Spill prevention for facilities located in State waters seaward of the coast line.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... ENVIRONMENTAL ENFORCEMENT, DEPARTMENT OF THE INTERIOR OFFSHORE OIL-SPILL RESPONSE REQUIREMENTS FOR FACILITIES LOCATED SEAWARD OF THE COAST LINE Oil-Spill Response Requirements for Facilities Located in State Waters... of the steps you are taking to prevent spills of oil or mitigate a substantial threat of such a...

  2. 30 CFR 254.54 - Spill prevention for facilities located in State waters seaward of the coast line.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... ENVIRONMENTAL ENFORCEMENT, DEPARTMENT OF THE INTERIOR OFFSHORE OIL-SPILL RESPONSE REQUIREMENTS FOR FACILITIES LOCATED SEAWARD OF THE COAST LINE Oil-Spill Response Requirements for Facilities Located in State Waters... of the steps you are taking to prevent spills of oil or mitigate a substantial threat of such a...

  3. Region 9 NPDES Facilities - Waste Water Treatment Plants

    EPA Pesticide Factsheets

    Point geospatial dataset representing locations of NPDES Waste Water Treatment Plant Facilities. NPDES (National Pollution Discharge Elimination System) is an EPA permit program that regulates direct discharges from facilities that discharge treated waste water into waters of the US. Facilities are issued NPDES permits regulating their discharge as required by the Clean Water Act. A facility may have one or more outfalls (dischargers). The location represents the facility or operating plant.

  4. 77 FR 42621 - Irradiation Treatment; Location of Facilities in the Southern United States

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-20

    .... APHIS-2009-0100] RIN 0579-AD35 Irradiation Treatment; Location of Facilities in the Southern United... amending the phytosanitary treatment regulations to provide generic criteria for new irradiation treatment facilities in the Southern States of the United States. This action will allow irradiation facilities to be...

  5. The LMOP Locator

    EPA Pesticide Factsheets

    This page contains the LMOP Locator, a tool that allows a user to geographically search for facilities that can potentially utilize LFG, or for landfills located near a facility that is interested in utilizing LFG.

  6. New spatial clustering-based models for optimal urban facility location considering geographical obstacles

    NASA Astrophysics Data System (ADS)

    Javadi, Maryam; Shahrabi, Jamal

    2014-03-01

    The problems of facility location and the allocation of demand points to facilities are crucial research issues in spatial data analysis and urban planning. It is very important for an organization or governments to best locate its resources and facilities and efficiently manage resources to ensure that all demand points are covered and all the needs are met. Most of the recent studies, which focused on solving facility location problems by performing spatial clustering, have used the Euclidean distance between two points as the dissimilarity function. Natural obstacles, such as mountains and rivers, can have drastic impacts on the distance that needs to be traveled between two geographical locations. While calculating the distance between various supply chain entities (including facilities and demand points), it is necessary to take such obstacles into account to obtain better and more realistic results regarding location-allocation. In this article, new models were presented for location of urban facilities while considering geographical obstacles at the same time. In these models, three new distance functions were proposed. The first function was based on the analysis of shortest path in linear network, which was called SPD function. The other two functions, namely PD and P2D, were based on the algorithms that deal with robot geometry and route-based robot navigation in the presence of obstacles. The models were implemented in ArcGIS Desktop 9.2 software using the visual basic programming language. These models were evaluated using synthetic and real data sets. The overall performance was evaluated based on the sum of distance from demand points to their corresponding facilities. Because of the distance between the demand points and facilities becoming more realistic in the proposed functions, results indicated desired quality of the proposed models in terms of quality of allocating points to centers and logistic cost. Obtained results show promising improvements of the allocation, the logistics costs and the response time. It can also be inferred from this study that the P2D-based model and the SPD-based model yield similar results in terms of the facility location and the demand allocation. It is noted that the P2D-based model showed better execution time than the SPD-based model. Considering logistic costs, facility location and response time, the P2D-based model was appropriate choice for urban facility location problem considering the geographical obstacles.

  7. Region 9 NPDES Facilities 2012- Waste Water Treatment Plants

    EPA Pesticide Factsheets

    Point geospatial dataset representing locations of NPDES Waste Water Treatment Plant Facilities. NPDES (National Pollution Discharge Elimination System) is an EPA permit program that regulates direct discharges from facilities that discharge treated waste water into waters of the US. Facilities are issued NPDES permits regulating their discharge as required by the Clean Water Act. A facility may have one or more outfalls (dischargers). The location represents the facility or operating plant.

  8. Competitive Facility Location with Random Demands

    NASA Astrophysics Data System (ADS)

    Uno, Takeshi; Katagiri, Hideki; Kato, Kosuke

    2009-10-01

    This paper proposes a new location problem of competitive facilities, e.g. shops and stores, with uncertain demands in the plane. By representing the demands for facilities as random variables, the location problem is formulated to a stochastic programming problem, and for finding its solution, three deterministic programming problems: expectation maximizing problem, probability maximizing problem, and satisfying level maximizing problem are considered. After showing that one of their optimal solutions can be found by solving 0-1 programming problems, their solution method is proposed by improving the tabu search algorithm with strategic vibration. Efficiency of the solution method is shown by applying to numerical examples of the facility location problems.

  9. Environmental justice: frequency and severity of US chemical industry accidents and the socioeconomic status of surrounding communities

    PubMed Central

    Elliott, M; Wang, Y; Lowe, R; Kleindorfer, P

    2004-01-01

    Study objectives: The Clean Air Act Amendments of 1990 requires that chemical facilities in the US with specified quantities of certain toxic or flammable chemicals file a five year history of accidents. This study considers the relation between the reported accidents and surrounding community characteristics. Design: This study is a retrospective analysis of the association between the demographics of counties in which facilities are located and the risk of accidental chemical release and resulting injuries at those facilities. The "location risk" (the risk that a facility having large volumes of hazardous chemicals is located in a community) and "operations risk" (the risk of an accident itself) are investigated. Setting:1994–2000 accident history data from 15 083 US industrial facilities using one or more of 140 flammable or toxic substances above a threshold level. Demographic makeup of 2333 counties surrounding these facilities was determined from the 1990 US census. Main results: Larger and more chemical intensive facilities tend to be located in counties with larger African-American populations and in counties with both higher median incomes and high levels of income inequality. Even after adjusting for location risk there is greater risk of accidents for facilities in heavily African-American counties (OR of accident = 1.9, 95% CI = 1.5 to 2.4). Conclusions: Further research and policy interventions are required to reduce the probability of locating facilities in an inequitable fashion, as well as health surveillance, and regulatory monitoring and enforcement activities to ensure that hazardous facilities in minority communities prepare and prevent accidental chemical releases to the same standards as elsewhere. PMID:14684723

  10. Solving the competitive facility location problem considering the reactions of competitor with a hybrid algorithm including Tabu Search and exact method

    NASA Astrophysics Data System (ADS)

    Bagherinejad, Jafar; Niknam, Azar

    2018-03-01

    In this paper, a leader-follower competitive facility location problem considering the reactions of the competitors is studied. A model for locating new facilities and determining levels of quality for the facilities of the leader firm is proposed. Moreover, changes in the location and quality of existing facilities in a competitive market where a competitor offers the same goods or services are taken into account. The competitor could react by opening new facilities, closing existing ones, and adjusting the quality levels of its existing facilities. The market share, captured by each facility, depends on its distance to customer and its quality that is calculated based on the probabilistic Huff's model. Each firm aims to maximize its profit subject to constraints on quality levels and budget of setting up new facilities. This problem is formulated as a bi-level mixed integer non-linear model. The model is solved using a combination of Tabu Search with an exact method. The performance of the proposed algorithm is compared with an upper bound that is achieved by applying Karush-Kuhn-Tucker conditions. Computational results show that our algorithm finds near the upper bound solutions in a reasonable time.

  11. EPA Facility Registry System (FRS): NCES

    EPA Pesticide Factsheets

    This web feature service contains location and facility identification information from EPA's Facility Registry System (FRS) for the subset of facilities that link to the National Center for Education Statistics (NCES). The primary federal database for collecting and analyzing data related to education in the United States and other Nations, NCES is located in the U.S. Department of Education, within the Institute of Education Sciences. FRS identifies and geospatially locates facilities, sites or places subject to environmental regulations or of environmental interest. Using vigorous verification and data management procedures, FRS integrates facility data from EPA00e2??s national program systems, other federal agencies, and State and tribal master facility records and provides EPA with a centrally managed, single source of comprehensive and authoritative information on facilities. This data set contains the subset of FRS integrated facilities that link to NCES school facilities once the NCES data has been integrated into the FRS database. Additional information on FRS is available at the EPA website http://www.epa.gov/enviro/html/fii/index.html.

  12. A Hybrid Tabu Search Heuristic for a Bilevel Competitive Facility Location Model

    NASA Astrophysics Data System (ADS)

    Küçükaydın, Hande; Aras, Necati; Altınel, I. Kuban

    We consider a problem in which a firm or franchise enters a market by locating new facilities where there are existing facilities belonging to a competitor. The firm aims at finding the location and attractiveness of each facility to be opened so as to maximize its profit. The competitor, on the other hand, can react by adjusting the attractiveness of its existing facilities, opening new facilities and/or closing existing ones with the objective of maximizing its own profit. The demand is assumed to be aggregated at certain points in the plane and the facilities of the firm can be located at prespecified candidate sites. We employ Huff's gravity-based rule in modeling the behavior of the customers where the fraction of customers at a demand point that visit a certain facility is proportional to the facility attractiveness and inversely proportional to the distance between the facility site and demand point. We formulate a bilevel mixed-integer nonlinear programming model where the firm entering the market is the leader and the competitor is the follower. In order to find a feasible solution of this model, we develop a hybrid tabu search heuristic which makes use of two exact methods as subroutines: a gradient ascent method and a branch-and-bound algorithm with nonlinear programming relaxation.

  13. Competitive Facility Location with Fuzzy Random Demands

    NASA Astrophysics Data System (ADS)

    Uno, Takeshi; Katagiri, Hideki; Kato, Kosuke

    2010-10-01

    This paper proposes a new location problem of competitive facilities, e.g. shops, with uncertainty and vagueness including demands for the facilities in a plane. By representing the demands for facilities as fuzzy random variables, the location problem can be formulated as a fuzzy random programming problem. For solving the fuzzy random programming problem, first the α-level sets for fuzzy numbers are used for transforming it to a stochastic programming problem, and secondly, by using their expectations and variances, it can be reformulated to a deterministic programming problem. After showing that one of their optimal solutions can be found by solving 0-1 programming problems, their solution method is proposed by improving the tabu search algorithm with strategic oscillation. The efficiency of the proposed method is shown by applying it to numerical examples of the facility location problems.

  14. EPA Facility Registry System (FRS): NEPT

    EPA Pesticide Factsheets

    This web feature service contains location and facility identification information from EPA's Facility Registry System (FRS) for the subset of facilities that link to the National Environmental Performance Track (NEPT) Program dataset. FRS identifies and geospatially locates facilities, sites or places subject to environmental regulations or of environmental interest. Using vigorous verification and data management procedures, FRS integrates facility data from EPA's national program systems, other federal agencies, and State and tribal master facility records and provides EPA with a centrally managed, single source of comprehensive and authoritative information on facilities. Additional information on FRS is available at the EPA website https://www.epa.gov/enviro/facility-registry-service-frs

  15. EPA Facility Registry Service (FRS): NEI

    EPA Pesticide Factsheets

    This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link to the National Emissions Inventory (NEI) Program dataset. FRS identifies and geospatially locates facilities, sites or places subject to environmental regulations or of environmental interest. Using vigorous verification and data management procedures, FRS integrates facility data from EPA's national program systems, other federal agencies, and State and tribal master facility records and provides EPA with a centrally managed, single source of comprehensive and authoritative information on facilities. Additional information on FRS is available at the EPA website https://www.epa.gov/enviro/facility-registry-service-frs

  16. Scaling and entropy in p-median facility location along a line

    NASA Astrophysics Data System (ADS)

    Gastner, Michael T.

    2011-09-01

    The p-median problem is a common model for optimal facility location. The task is to place p facilities (e.g., warehouses or schools) in a heterogeneously populated space such that the average distance from a person's home to the nearest facility is minimized. Here we study the special case where the population lives along a line (e.g., a road or a river). If facilities are optimally placed, the length of the line segment served by a facility is inversely proportional to the square root of the population density. This scaling law is derived analytically and confirmed for concrete numerical examples of three US interstate highways and the Mississippi River. If facility locations are permitted to deviate from the optimum, the number of possible solutions increases dramatically. Using Monte Carlo simulations, we compute how scaling is affected by an increase in the average distance to the nearest facility. We find that the scaling exponents change and are most sensitive near the optimum facility distribution.

  17. 14 CFR 21.165 - Responsibility of holder.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... supplier and subsequently found not to conform to the applicable design data. (d) Manufacturing process... facilities. (a) An applicant may obtain a production certificate for manufacturing facilities located outside... before making any changes to the location of any of its manufacturing facilities. (c) The production...

  18. 33 CFR 137.65 - Visual inspections of the facility, the real property on which the facility is located, and...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... rights-of-way, or other vantage point (e.g., aerial photography), including a visual inspection of areas... the facility is located from the nearest accessible vantage point, such as the property line or public...

  19. Cuckoo search via Levy flights applied to uncapacitated facility location problem

    NASA Astrophysics Data System (ADS)

    Mesa, Armacheska; Castromayor, Kris; Garillos-Manliguez, Cinmayii; Calag, Vicente

    2017-11-01

    Facility location problem (FLP) is a mathematical way to optimally locate facilities within a set of candidates to satisfy the requirements of a given set of clients. This study addressed the uncapacitated FLP as it assures that the capacity of every selected facility is finite. Thus, even if the demand is not known, which often is the case, in reality, organizations may still be able to take strategic decisions such as locating the facilities. There are different approaches relevant to the uncapacitated FLP. Here, the cuckoo search via Lévy flight (CS-LF) was used to solve the problem. Though hybrid methods produce better results, this study employed CS-LF to determine first its potential in finding solutions for the problem, particularly when applied to a real-world problem. The method was applied to the data set obtained from a department store in Davao City, Philippines. Results showed that applying CS-LF yielded better facility locations compared to particle swarm optimization and other existing algorithms. Although these results showed that CS-LF is a promising method to solve this particular problem, further studies on other FLP are recommended to establish a strong foundation of the capability of CS-LF in solving FLP.

  20. Planning of public healthcare facility using a location allocation modelling: A case study

    NASA Astrophysics Data System (ADS)

    Shariff, S. Sarifah Radiah; Moin, Noor Hasnah; Omar, Mohd

    2014-09-01

    Finding the correct location of any facility and determining the demands which are to be assigned to it is very crucial in public health service. This is to ensure that the public gain maximum benefits. This article analyzes the previous location decisions of public primary healthcare (PHC) facilities in the district of Kuala Langat, Malaysia. With total population of 220214 (in 2010), the PHC in the district is currently served by 28 facilities. The percentages of total population covered (in 2007) within the maximum allowable distance of 3km and 5km are 69.7 percent and 77.8 percent respectively. This is very low compared to the Malaysian National Health Policy of Health for All or 100 percent coverage. The determination of health facility location should be planned carefully to further increase effective primary health service to the nation that is required for economic sustainability.

  1. A heuristic approach to handle capacitated facility location problem evaluated using clustering internal evaluation

    NASA Astrophysics Data System (ADS)

    Sutanto, G. R.; Kim, S.; Kim, D.; Sutanto, H.

    2018-03-01

    One of the problems in dealing with capacitated facility location problem (CFLP) is occurred because of the difference between the capacity numbers of facilities and the number of customers that needs to be served. A facility with small capacity may result in uncovered customers. These customers need to be re-allocated to another facility that still has available capacity. Therefore, an approach is proposed to handle CFLP by using k-means clustering algorithm to handle customers’ allocation. And then, if customers’ re-allocation is needed, is decided by the overall average distance between customers and the facilities. This new approach is benchmarked to the existing approach by Liao and Guo which also use k-means clustering algorithm as a base idea to decide the facilities location and customers’ allocation. Both of these approaches are benchmarked by using three clustering evaluation methods with connectedness, compactness, and separations factors.

  2. 14 CFR 21.137 - Location of manufacturing facilities.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Location of manufacturing facilities. 21.137 Section 21.137 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT CERTIFICATION PROCEDURES FOR PRODUCTS AND PARTS Production Certificates § 21.137 Location of...

  3. 40 CFR 265.18 - Location standards.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 25 2010-07-01 2010-07-01 false Location standards. 265.18 Section 265.18 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED... FACILITIES General Facility Standards § 265.18 Location standards. The placement of any hazardous waste in a...

  4. 14 CFR 21.43 - Location of manufacturing facilities.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Location of manufacturing facilities. 21.43 Section 21.43 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT.... Except as provided in § 21.29, the FAA does not issue a type certificate if the manufacturing facilities...

  5. 14 CFR 21.43 - Location of manufacturing facilities.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Location of manufacturing facilities. 21.43 Section 21.43 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT.... Except as provided in § 21.29, the FAA does not issue a type certificate if the manufacturing facilities...

  6. 14 CFR 21.43 - Location of manufacturing facilities.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Location of manufacturing facilities. 21.43 Section 21.43 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT.... Except as provided in § 21.29, the FAA does not issue a type certificate if the manufacturing facilities...

  7. 76 FR 179 - GMPT Warren Transmission, GM Powertrain Division, a Subsidiary of General Motors Company...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-03

    ... Knight Facilities Management, Warren, MI; Amended Certification Regarding Eligibility To Apply for Worker... Knight Facilities Management were employed on-site at the Warren, Michigan location of the subject firm... Knight Facilities Management working on-site at the Warren, Michigan location of GMPT Warren Transmission...

  8. 46 CFR 108.233 - Location and size.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... EQUIPMENT Construction and Arrangement Helicopter Facilities § 108.233 Location and size. (a) Each helicopter deck must be— (1) At least the size of the rotor diameter of the largest single main rotor helicopter that will be used on the facility; or (2) If tandem main rotor helicopters use the facility, at...

  9. 46 CFR 108.233 - Location and size.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... EQUIPMENT Construction and Arrangement Helicopter Facilities § 108.233 Location and size. (a) Each helicopter deck must be— (1) At least the size of the rotor diameter of the largest single main rotor helicopter that will be used on the facility; or (2) If tandem main rotor helicopters use the facility, at...

  10. 46 CFR 108.233 - Location and size.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... EQUIPMENT Construction and Arrangement Helicopter Facilities § 108.233 Location and size. (a) Each helicopter deck must be— (1) At least the size of the rotor diameter of the largest single main rotor helicopter that will be used on the facility; or (2) If tandem main rotor helicopters use the facility, at...

  11. 46 CFR 108.233 - Location and size.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... EQUIPMENT Construction and Arrangement Helicopter Facilities § 108.233 Location and size. (a) Each helicopter deck must be— (1) At least the size of the rotor diameter of the largest single main rotor helicopter that will be used on the facility; or (2) If tandem main rotor helicopters use the facility, at...

  12. 46 CFR 108.233 - Location and size.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... EQUIPMENT Construction and Arrangement Helicopter Facilities § 108.233 Location and size. (a) Each helicopter deck must be— (1) At least the size of the rotor diameter of the largest single main rotor helicopter that will be used on the facility; or (2) If tandem main rotor helicopters use the facility, at...

  13. Locations and attributes of wind turbines in Colorado, 2009

    USGS Publications Warehouse

    Carr, Natasha B.; Diffendorfer, Jay E.; Fancher, Tammy S.; Latysh, Natalie E.; Leib, Kenneth J.; Matherne, Anne-Marie; Turner, Christine

    2011-01-01

    The Colorado wind-turbine data series provides geospatial data for all wind turbines established within the State as of August 2009. Attributes specific to each turbine include: turbine location, manufacturer and model, rotor diameter, hub height, rotor height, potential megawatt output, land ownership, and county. Wind energy facility data for each turbine include: facility name, facility power capacity, number of turbines associated with each facility to date, facility developer, facility ownership, year the facility went online, and development status of wind facility. Turbine locations were derived from August 2009 1-meter true-color aerial photographs produced by the National Agriculture Imagery Program; the photographs have a positional accuracy of about + or - 5 meters. The location of turbines under construction during August 2009 likely will be less accurate than the location of existing turbines. This data series contributes to an Online Interactive Energy Atlas currently (2011) in development by the U.S. Geological Survey. The Energy Atlas will synthesize data on existing and potential energy development in Colorado and New Mexico and will include additional natural resource data layers. This information may be used by decisionmakers to evaluate and compare the potential benefits and tradeoffs associated with different energy development strategies or scenarios. Interactive maps, downloadable data layers, comprehensive metadata, and decision-support tools will be included in the Energy Atlas. The format of the Energy Atlas will facilitate the integration of information about energy with key terrestrial and aquatic resources for evaluating resource values and minimizing risks from energy development.

  14. Locations and attributes of wind turbines in New Mexico, 2009

    USGS Publications Warehouse

    Carr, Natasha B.; Diffendorfer, Jay E.; Fancher, Tammy S.; Latysh, Natalie E.; Leib, Kenneth J.; Matherne, Anne-Marie; Turner, Christine

    2011-01-01

    The New Mexico wind-turbine data series provides geospatial data for all wind turbines established within the State as of August 2009. Attributes specific to each turbine include: turbine location, manufacturer and model, rotor diameter, hub height, rotor height, potential megawatt output, land ownership, and county. Wind energy facility data for each turbine include: facility name, facility power capacity, number of turbines associated with each facility to date, facility developer, facility ownership, year the facility went online, and development status of wind facility. Turbine locations were derived from 1-meter August 2009 true-color aerial photographs produced by the National Agriculture Imagery Program; the photographs have a positional accuracy of about + or - 5 meters. The location of turbines under construction during August 2009 likely will be less accurate than the location of existing turbines. This data series contributes to an Online Interactive Energy Atlas currently (2011) in development by the U.S. Geological Survey. The Energy Atlas will synthesize data on existing and potential energy development in Colorado and New Mexico and will include additional natural resource data layers. This information may be used by decisionmakers to evaluate and compare the potential benefits and tradeoffs associated with different energy development strategies or scenarios. Interactive maps, downloadable data layers, comprehensive metadata, and decision-support tools will be included in the Energy Atlas. The format of the Energy Atlas will facilitate the integration of information about energy with key terrestrial and aquatic resources for evaluating resource values and minimizing risks from energy development.

  15. Accreditation status and geographic location of outpatient vascular testing facilities among Medicare beneficiaries: the VALUE (Vascular Accreditation, Location & Utilization Evaluation) study.

    PubMed

    Rundek, Tatjana; Brown, Scott C; Wang, Kefeng; Dong, Chuanhui; Farrell, Mary Beth; Heller, Gary V; Gornik, Heather L; Hutchisson, Marge; Needleman, Laurence; Benenati, James F; Jaff, Michael R; Meier, George H; Perese, Susana; Bendick, Phillip; Hamburg, Naomi M; Lohr, Joann M; LaPerna, Lucy; Leers, Steven A; Lilly, Michael P; Tegeler, Charles; Alexandrov, Andrei V; Katanick, Sandra L

    2014-10-01

    There is limited information on the accreditation status and geographic distribution of vascular testing facilities in the US. The Centers for Medicare & Medicaid Services (CMS) provide reimbursement to facilities regardless of accreditation status. The aims were to: (1) identify the proportion of Intersocietal Accreditation Commission (IAC) accredited vascular testing facilities in a 5% random national sample of Medicare beneficiaries receiving outpatient vascular testing services; (2) describe the geographic distribution of these facilities. The VALUE (Vascular Accreditation, Location & Utilization Evaluation) Study examines the proportion of IAC accredited facilities providing vascular testing procedures nationally, and the geographic distribution and utilization of these facilities. The data set containing all facilities that billed Medicare for outpatient vascular testing services in 2011 (5% CMS Outpatient Limited Data Set (LDS) file) was examined, and locations of outpatient vascular testing facilities were obtained from the 2011 CMS/Medicare Provider of Services (POS) file. Of 13,462 total vascular testing facilities billing Medicare for vascular testing procedures in a 5% random Outpatient LDS for the US in 2011, 13% (n=1730) of facilities were IAC accredited. The percentage of IAC accredited vascular testing facilities in the LDS file varied significantly by US region, p<0.0001: 26%, 12%, 11%, and 7% for the Northeast, South, Midwest, and Western regions, respectively. Findings suggest that the proportion of outpatient vascular testing facilities that are IAC accredited is low and varies by region. Increasing the number of accredited vascular testing facilities to improve test quality is a hypothesis that should be tested in future research. © The Author(s) 2014.

  16. Strategic planning and marketing research for older, inner-city health care facilities: a case study.

    PubMed

    Wood, V R; Robertson, K R

    1992-01-01

    Numerous health care facilities, located in downtown metropolitan areas, now find themselves surrounded by a decaying inner-city environment. Consumers may perceive these facilities as "old," and catering to an "urban poor" consumer. These same consumers may, therefore, prefer to patronize more modern facilities located in suburban areas. This paper presents a case study of such a health care facility and how strategic planning and marketing research were conducted in order to identify market opportunities and new strategic directions.

  17. 78 FR 37760 - Electrical Equipment in Hazardous Locations

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-24

    ... floating facilities engaged in OCS activities, however, equipment could be installed in hazardous locations... composition and the extent of equipment replacement. The myriad types of MODUs and facilities operating on the.... USCG-2012-0850] RIN 1625-AC00 Electrical Equipment in Hazardous Locations AGENCY: Coast Guard, DHS...

  18. Methods for detecting and locating leaks in containment facilities using electrical potential data and electrical resistance tomographic imaging techniques

    DOEpatents

    Daily, William D.; Laine, Daren L.; Laine, Edwin F.

    2001-01-01

    Methods are provided for detecting and locating leaks in liners used as barriers in the construction of landfills, surface impoundments, water reservoirs, tanks, and the like. Electrodes are placed in the ground around the periphery of the facility, in the leak detection zone located between two liners if present, and/or within the containment facility. Electrical resistivity data is collected using these electrodes. This data is used to map the electrical resistivity distribution beneath the containment liner or between two liners in a double-lined facility. In an alternative embodiment, an electrode placed within the lined facility is driven to an electrical potential with respect to another electrode placed at a distance from the lined facility (mise-a-la-masse). Voltage differences are then measured between various combinations of additional electrodes placed in the soil on the periphery of the facility, the leak detection zone, or within the facility. A leak of liquid through the liner material will result in an electrical potential distribution that can be measured at the electrodes. The leak position is located by determining the coordinates of an electrical current source pole that best fits the measured potentials with the constraints of the known or assumed resistivity distribution.

  19. Methods for detecting and locating leaks in containment facilities using electrical potential data and electrical resistance tomographic imaging techniques

    DOEpatents

    Daily, William D.; Laine, Daren L.; Laine, Edwin F.

    1997-01-01

    Methods are provided for detecting and locating leaks in liners used as barriers in the construction of landfills, surface impoundments, water reservoirs, tanks, and the like. Electrodes are placed in the ground around the periphery of the facility, in the leak detection zone located between two liners if present, and/or within the containment facility. Electrical resistivity data is collected using these electrodes. This data is used to map the electrical resistivity distribution beneath the containment liner between two liners in a double-lined facility. In an alternative embodiment, an electrode placed within the lined facility is driven to an electrical potential with respect to another electrode placed at a distance from the lined facility (mise-a-la-masse). Voltage differences are then measured between various combinations of additional electrodes placed in the soil on the periphery of the facility, the leak detection zone, or within the facility. A leak of liquid though the liner material will result in an electrical potential distribution that can be measured at the electrodes. The leak position is located by determining the coordinates of an electrical current source pole that best fits the measured potentials with the constraints of the known or assumed resistivity distribution.

  20. Methods for detecting and locating leaks in containment facilities using electrical potential data and electrical resistance tomographic imaging techniques

    DOEpatents

    Daily, W.D.; Laine, D.L.; Laine, E.F.

    1997-08-26

    Methods are provided for detecting and locating leaks in liners used as barriers in the construction of landfills, surface impoundments, water reservoirs, tanks, and the like. Electrodes are placed in the ground around the periphery of the facility, in the leak detection zone located between two liners if present, and/or within the containment facility. Electrical resistivity data is collected using these electrodes. This data is used to map the electrical resistivity distribution beneath the containment liner between two liners in a double-lined facility. In an alternative embodiment, an electrode placed within the lined facility is driven to an electrical potential with respect to another electrode placed at a distance from the lined facility (mise-a-la-masse). Voltage differences are then measured between various combinations of additional electrodes placed in the soil on the periphery of the facility, the leak detection zone, or within the facility. A leak of liquid though the liner material will result in an electrical potential distribution that can be measured at the electrodes. The leak position is located by determining the coordinates of an electrical current source pole that best fits the measured potentials with the constraints of the known or assumed resistivity distribution. 6 figs.

  1. MIP models for connected facility location: A theoretical and computational study☆

    PubMed Central

    Gollowitzer, Stefan; Ljubić, Ivana

    2011-01-01

    This article comprises the first theoretical and computational study on mixed integer programming (MIP) models for the connected facility location problem (ConFL). ConFL combines facility location and Steiner trees: given a set of customers, a set of potential facility locations and some inter-connection nodes, ConFL searches for the minimum-cost way of assigning each customer to exactly one open facility, and connecting the open facilities via a Steiner tree. The costs needed for building the Steiner tree, facility opening costs and the assignment costs need to be minimized. We model ConFL using seven compact and three mixed integer programming formulations of exponential size. We also show how to transform ConFL into the Steiner arborescence problem. A full hierarchy between the models is provided. For two exponential size models we develop a branch-and-cut algorithm. An extensive computational study is based on two benchmark sets of randomly generated instances with up to 1300 nodes and 115,000 edges. We empirically compare the presented models with respect to the quality of obtained bounds and the corresponding running time. We report optimal values for all but 16 instances for which the obtained gaps are below 0.6%. PMID:25009366

  2. 28. MAP SHOWING LOCATION OF ARVFS FACILITY AS BUILT. SHOWS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    28. MAP SHOWING LOCATION OF ARVFS FACILITY AS BUILT. SHOWS LINCOLN BOULEVARD, BIG LOST RIVER, AND NAVAL REACTORS FACILITY. F.C. TORKELSON DRAWING NUMBER 842-ARVFS-101-2. DATED OCTOBER 12, 1965. INEL INDEX CODE NUMBER: 075 0101 851 151969. - Idaho National Engineering Laboratory, Advanced Reentry Vehicle Fusing System, Scoville, Butte County, ID

  3. Library Facility Siting and Location Handbook. The Greenwood Library Management Collection.

    ERIC Educational Resources Information Center

    Koontz, Christine M.

    This handbook is a guide to the complex process of library facility siting and location. It includes relevant research and professionals' siting experiences, as well as actual case studies of closures, openings, mergers, and relocations of library facilities. While the bulk of the volume provides practical information, the work also presents an…

  4. 75 FR 11916 - Chrysler Transportation LLC, a Subsidiary of Chrysler LLC, Including On-Site Leased Workers from...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-12

    ... Chrysler manufacturing facilities, a substantial portion of which are shipped to an affiliated plant where... Caravan Knight Facilities Management LLC were employed on-site at the Detroit, Michigan location of... Knight Facilities Management, LLC, working on-site at the Detroit, Michigan location of Chrysler...

  5. 30 CFR 254.54 - Spill prevention for facilities located in State waters seaward of the coast line.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... MANAGEMENT, REGULATION, AND ENFORCEMENT, DEPARTMENT OF THE INTERIOR OFFSHORE OIL-SPILL RESPONSE REQUIREMENTS FOR FACILITIES LOCATED SEAWARD OF THE COAST LINE Oil-Spill Response Requirements for Facilities... Regional Supervisor a description of the steps you are taking to prevent spills of oil or mitigate a...

  6. 19 CFR 19.2 - Applications to bond.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... officials of the warehouse and all persons who have a direct or indirect financial interest in the operation... facility will be determined by street address, location, or both. For example, if a proprietor has two... two located at one address would be considered as one warehouse facility and the three located at...

  7. 19 CFR 19.2 - Applications to bond.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... officials of the warehouse and all persons who have a direct or indirect financial interest in the operation... facility will be determined by street address, location, or both. For example, if a proprietor has two... two located at one address would be considered as one warehouse facility and the three located at...

  8. 19 CFR 19.2 - Applications to bond.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... officials of the warehouse and all persons who have a direct or indirect financial interest in the operation... facility will be determined by street address, location, or both. For example, if a proprietor has two... two located at one address would be considered as one warehouse facility and the three located at...

  9. Coastal Energy Corporation, Willow Springs, MO

    EPA Pesticide Factsheets

    notice of a proposed Administrative Penalty Assessment against Coastal Energy Corporation, located at 232 Burnham Road, Willow Springs, Missouri, for alleged violations at the facility located at or near that facility.

  10. Onshore industrial wind turbine locations for the United States

    USGS Publications Warehouse

    Diffendorfer, Jay E.; Compton, Roger; Kramer, Louisa; Ancona, Zach; Norton, Donna

    2017-01-01

    This dataset provides industrial-scale onshore wind turbine locations in the United States, corresponding facility information, and turbine technical specifications. The database has wind turbine records that have been collected, digitized, locationally verified, and internally quality controlled. Turbines from the Federal Aviation Administration Digital Obstacles File, through product release date July 22, 2013, were used as the primary source of turbine data points. The dataset was subsequently revised and reposted as described in the revision histories for the report. Verification of the turbine positions was done by visual interpretation using high-resolution aerial imagery in Environmental Systems Research Institute (Esri) ArcGIS Desktop. Turbines without Federal Aviation Administration Obstacles Repository System numbers were visually identified and point locations were added to the collection. We estimated a locational error of plus or minus 10 meters for turbine locations. Wind farm facility names were identified from publicly available facility datasets. Facility names were then used in a Web search of additional industry publications and press releases to attribute additional turbine information (such as manufacturer, model, and technical specifications of wind turbines). Wind farm facility location data from various wind and energy industry sources were used to search for and digitize turbines not in existing databases. Technical specifications for turbines were assigned based on the wind turbine make and model as described in literature, specifications listed in the Federal Aviation Administration Digital Obstacles File, and information on the turbine manufacturer’s Web site. Some facility and turbine information on make and model did not exist or was difficult to obtain. Thus, uncertainty may exist for certain turbine specifications. That uncertainty was rated and a confidence was recorded for both location and attribution data quality.

  11. Locations and attributes of wind turbines in Colorado, 2011

    USGS Publications Warehouse

    Carr, Natasha B.; Diffendorfer, James E.; Fancher, Tammy; Hawkins, Sarah J.; Latysh, Natalie; Leib, Kenneth J.; Matherne, Anne Marie

    2013-01-01

    This dataset represents an update to U.S. Geological Survey Data Series 597. Locations and attributes of wind turbines in Colorado, 2009 (available at http://pubs.usgs.gov/ds/597/). This updated Colorado wind turbine Data Series provides geospatial data for all 1,204 wind turbines established within the State of Colorado as of September 2011, an increase of 297 wind turbines from 2009. Attributes specific to each turbine include: turbine location, manufacturer and model, rotor diameter, hub height, rotor height, potential megawatt output, land ownership, county, and development status of the wind turbine. Wind energy facility data for each turbine include: facility name, facility power capacity, number of turbines associated with each facility to date, facility developer, facility ownership, and year the facility went online. The locations of turbines are derived from 1-meter true-color aerial photographs produced by the National Agriculture Imagery Program (NAIP); the photographs have a positional accuracy of about ±5 meters. Locations of turbines constructed during or prior to August 2009 are based on August 2009 NAIP imagery and turbine locations constructed after August 2009 were based on September 2011 NAIP imagery. The location of turbines under construction during September 2011 likely will be less accurate than the location of existing turbines. This data series contributes to an Online Interactive Energy Atlas developed by the U.S. Geological Survey (http://my.usgs.gov/eerma/). The Energy Atlas synthesizes data on existing and potential energy development in Colorado and New Mexico and includes additional natural resource data layers. This information may be used by decisionmakers to evaluate and compare the potential benefits and tradeoffs associated with different energy development strategies or scenarios. Interactive maps, downloadable data layers, comprehensive metadata, and decision-support tools also are included in the Energy Atlas. The format of the Energy Atlas is designed to facilitate the integration of information about energy with key terrestrial and aquatic resources for evaluating resource values and minimizing risks from energy development.

  12. Locations and attributes of wind turbines in New Mexico, 2011

    USGS Publications Warehouse

    Carr, Natasha B.; Diffendorfer, James B.; Fancher, Tammy; Hawkins, Sarah J.; Latysh, Natalie; Leib, Kenneth J.; Matherne, Anne Marie

    2013-01-01

    This dataset represents an update to U.S. Geological Survey Data Series 596. Locations and attributes of wind turbines in New Mexico, 2009 (available at http://pubs.usgs.gov/ds/596/).This updated New Mexico wind turbine Data Series provides geospatial data for all 562 wind turbines established within the State of New Mexico as of June 2011, an increase of 155 wind turbines from 2009. Attributes specific to each turbine include: turbine location, manufacturer and model, rotor diameter, hub height, rotor height, potential megawatt output, land ownership, county, and development status of wind turbine. Wind energy facility data for each turbine include: facility name, facility power capacity, number of turbines associated with each facility to date, facility developer, facility ownership, and year the facility went online. The locations of turbines are derived from 1-meter true-color aerial photographs produced by the National Agriculture Imagery Program (NAIP); the photographs have a positional accuracy of about ±5 meters. The locations of turbines constructed during or prior to August 2009 are based on August 2009 NAIP imagery and turbine locations constructed after August 2009 were based June 2011 NAIP imagery. The location of turbines under construction during June 2011 likely will be less accurate than the location of existing turbines. This data series contributes to an Online Interactive Energy Atlas developed by the U.S. Geological Survey (http://my.usgs.gov/eerma/). The Energy Atlas synthesizes data on existing and potential energy development in Colorado and New Mexico and includes additional natural resource data layers. This information may be used by decisionmakers to evaluate and compare the potential benefits and tradeoffs associated with different energy development strategies or scenarios. Interactive maps, downloadable data layers, comprehensive metadata, and decision-support tools also are included in the Energy Atlas. The format of the Energy Atlas is designed to facilitate the integration of information about energy with key terrestrial and aquatic resources for evaluating resource values and minimizing risks from energy development.

  13. Do objective neighbourhood characteristics relate to residents' preferences for certain sports locations? A cross-sectional study using a discrete choice modelling approach.

    PubMed

    Deelen, Ineke; Jansen, Marijke; Dogterom, Nico J; Kamphuis, Carlijn B M; Ettema, Dick

    2017-12-11

    The number of sports facilities, sports clubs, or city parks in a residential neighbourhood may affect the likelihood that people participate in sports and their preferences for a certain sports location. This study aimed to assess whether objective physical and socio-spatial neighbourhood characteristics relate to sports participation and preferences for sports locations. Data from Dutch adults (N = 1201) on sports participation, their most-used sports location, and socio-demographic characteristics were collected using an online survey. Objective land-use data and the number of sports facilities were gathered for each participant using a 2000-m buffer around their home locations, whereas socio-spatial neighbourhood characteristics (i.e., density, socio-economic status, and safety) were determined at the neighbourhood level. A discrete choice-modelling framework (multinomial probit model) was used to model the associations between neighbourhood characteristics and sports participation and location. Higher proportions of green space, blue space, and the number of sports facilities were positively associated with sports participation in public space, at sports clubs, and at other sports facilities. Higher degrees of urbanization were negatively associated with sports participation at public spaces, sports clubs, and other sports facilities. Those with more green space, blue space or sports facilities in their residential neighbourhood were more likely to participate in sports, but these factors did not affect their preference for a certain sports location. Longitudinal study designs are necessary to assess causality: do active people choose to live in sports-facilitating neighbourhoods, or do neighbourhood characteristics affect sports participation?

  14. Coastal Energy Corporation, Willow Springs, MO - Public Notice Document

    EPA Pesticide Factsheets

    Notice of a proposed Administrative Penalty Assessment against Coastal Energy Corporation, located at 232 Burnham Road, Willow Springs, Missouri, for alleged violations at the facility located at or near that facility

  15. 30 CFR 254.51 - Modifying an existing OCS response plan.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., DEPARTMENT OF THE INTERIOR OFFSHORE OIL-SPILL RESPONSE REQUIREMENTS FOR FACILITIES LOCATED SEAWARD OF THE COAST LINE Oil-Spill Response Requirements for Facilities Located in State Waters Seaward of the Coast...

  16. EPA Facility Registry Service (FRS): OIL

    EPA Pesticide Factsheets

    This dataset contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link to the Oil database. The Oil database contains information on Spill Prevention, Control, and Countermeasure (SPCC) and Facility Response Plan (FRP) subject facilities to prevent and respond to oil spills. FRP facilities are referred to as substantial harm facilities due to the quantities of oil stored and facility characteristics. FRS identifies and geospatially locates facilities, sites or places subject to environmental regulations or of environmental interest. Using vigorous verification and data management procedures, FRS integrates facility data from EPA's national program systems, other federal agencies, and State and tribal master facility records and provides EPA with a centrally managed, single source of comprehensive and authoritative information on facilities. This data set contains the subset of FRS integrated facilities that link to Oil facilities once the Oil data has been integrated into the FRS database. Additional information on FRS is available at the EPA website https://www.epa.gov/enviro/facility-registry-service-frs.

  17. 18 CFR 292.208 - Special requirements for hydroelectric small power production facilities located at a new dam or...

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... for hydroelectric small power production facilities located at a new dam or diversion. 292.208 Section... 201 AND 210 OF THE PUBLIC UTILITY REGULATORY POLICIES ACT OF 1978 WITH REGARD TO SMALL POWER PRODUCTION AND COGENERATION Qualifying Cogeneration and Small Power Production Facilities § 292.208 Special...

  18. 18 CFR 292.208 - Special requirements for hydroelectric small power production facilities located at a new dam or...

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... for hydroelectric small power production facilities located at a new dam or diversion. 292.208 Section... 201 AND 210 OF THE PUBLIC UTILITY REGULATORY POLICIES ACT OF 1978 WITH REGARD TO SMALL POWER PRODUCTION AND COGENERATION Qualifying Cogeneration and Small Power Production Facilities § 292.208 Special...

  19. 34 CFR 395.30 - The location and operation of vending facilities for blind vendors on Federal property.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... blind vendors on Federal property. 395.30 Section 395.30 Education Regulations of the Offices of the... EDUCATION VENDING FACILITY PROGRAM FOR THE BLIND ON FEDERAL AND OTHER PROPERTY Federal Property Management § 395.30 The location and operation of vending facilities for blind vendors on Federal property. (a...

  20. 34 CFR 395.30 - The location and operation of vending facilities for blind vendors on Federal property.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... EDUCATION VENDING FACILITY PROGRAM FOR THE BLIND ON FEDERAL AND OTHER PROPERTY Federal Property Management... 34 Education 2 2011-07-01 2010-07-01 true The location and operation of vending facilities for blind vendors on Federal property. 395.30 Section 395.30 Education Regulations of the Offices of the...

  1. 34 CFR 395.30 - The location and operation of vending facilities for blind vendors on Federal property.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... blind vendors on Federal property. 395.30 Section 395.30 Education Regulations of the Offices of the... EDUCATION VENDING FACILITY PROGRAM FOR THE BLIND ON FEDERAL AND OTHER PROPERTY Federal Property Management § 395.30 The location and operation of vending facilities for blind vendors on Federal property. (a...

  2. 34 CFR 395.30 - The location and operation of vending facilities for blind vendors on Federal property.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... blind vendors on Federal property. 395.30 Section 395.30 Education Regulations of the Offices of the... EDUCATION VENDING FACILITY PROGRAM FOR THE BLIND ON FEDERAL AND OTHER PROPERTY Federal Property Management § 395.30 The location and operation of vending facilities for blind vendors on Federal property. (a...

  3. 34 CFR 395.30 - The location and operation of vending facilities for blind vendors on Federal property.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... blind vendors on Federal property. 395.30 Section 395.30 Education Regulations of the Offices of the... EDUCATION VENDING FACILITY PROGRAM FOR THE BLIND ON FEDERAL AND OTHER PROPERTY Federal Property Management § 395.30 The location and operation of vending facilities for blind vendors on Federal property. (a...

  4. Urbanization and Spatial Organization: Hospital and Orphanage Location in Chicago, 1848-1916

    ERIC Educational Resources Information Center

    Britton, Marcus; Ocasio, William

    2007-01-01

    What factors affect where organizations locate facilities in local communities? This paper examines how urban development influenced the neighborhood location of two very different types of facilities, general hospitals and orphanages, over the 70-year period during which Chicago emerged as an urban metropolis. Our results suggest that the human…

  5. 42 CFR 37.4 - Plans for chest roentgenographic examinations.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... covered by the plan; (4) The name and location of the approved X-ray facility or facilities, and the... approval as the originally approved plan. (e) The operator must promptly display in a visible location on... NIOSH. The proposed plan or change in plan must remain posted in a visible location on the bulletin...

  6. 10 CFR 75.2 - Scope.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... location of a uranium or thorium mine or concentration plant (e.g., in-situ leach mines and activities... holders: (1) A facility, as defined in § 75.4, and the site of the facility; (2) A location performing nuclear fuel cycle-related research and development, as defined in § 75.4; (3) A location manufacturing...

  7. 10 CFR 75.2 - Scope.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... location of a uranium or thorium mine or concentration plant (e.g., in-situ leach mines and activities... holders: (1) A facility, as defined in § 75.4, and the site of the facility; (2) A location performing nuclear fuel cycle-related research and development, as defined in § 75.4; (3) A location manufacturing...

  8. 10 CFR 75.2 - Scope.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... location of a uranium or thorium mine or concentration plant (e.g., in-situ leach mines and activities... holders: (1) A facility, as defined in § 75.4, and the site of the facility; (2) A location performing nuclear fuel cycle-related research and development, as defined in § 75.4; (3) A location manufacturing...

  9. 10 CFR 75.2 - Scope.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... location of a uranium or thorium mine or concentration plant (e.g., in-situ leach mines and activities... holders: (1) A facility, as defined in § 75.4, and the site of the facility; (2) A location performing nuclear fuel cycle-related research and development, as defined in § 75.4; (3) A location manufacturing...

  10. 10 CFR 75.2 - Scope.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... location of a uranium or thorium mine or concentration plant (e.g., in-situ leach mines and activities... holders: (1) A facility, as defined in § 75.4, and the site of the facility; (2) A location performing nuclear fuel cycle-related research and development, as defined in § 75.4; (3) A location manufacturing...

  11. Reliable Facility Location Problem with Facility Protection

    PubMed Central

    Tang, Luohao; Zhu, Cheng; Lin, Zaili; Shi, Jianmai; Zhang, Weiming

    2016-01-01

    This paper studies a reliable facility location problem with facility protection that aims to hedge against random facility disruptions by both strategically protecting some facilities and using backup facilities for the demands. An Integer Programming model is proposed for this problem, in which the failure probabilities of facilities are site-specific. A solution approach combining Lagrangian Relaxation and local search is proposed and is demonstrated to be both effective and efficient based on computational experiments on random numerical examples with 49, 88, 150 and 263 nodes in the network. A real case study for a 100-city network in Hunan province, China, is presented, based on which the properties of the model are discussed and some managerial insights are analyzed. PMID:27583542

  12. Physician alignment strategies and real estate.

    PubMed

    Czerniak, Thomas A

    2012-06-01

    When addressing locations of facilities after acquiring physician practices, hospitals should: Acknowledge the hospital's ambulatory plan is the driver rather than real estate assumed with the physician practices, Review the hospital ambulatory service plan for each submarket, Review the location of facilities within the service area and their proximity to one another, Sublease or sell existing facilities that are not appropriate, Ensure that the size and characteristics of each facility in the market are appropriate and consistent with the hospital's image.

  13. Design and Development of E3 Antenna Container,

    DTIC Science & Technology

    1985-09-03

    reinforced with square tubing. The walls and ceiling shall be insulated with expanded polystyrene . TEST LOCATION - This test will be performed at the...ceiling shall be insulated with expanded polystyrene . TEST LOCATION - This test will be performed at the Edgewater Machine & Fabricator’s facility...insulated with expanded polystyrene . TEST LOCATION - This test will be performed at the Edgewater Machine & Fabricator’s facility located at 200 N

  14. 76 FR 68170 - Instructions for Implementing Sustainable Locations for Federal Facilities in Accordance With...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-03

    ... for integrating sustainable facility location decision-making principles into agency policies and..., Energy, and Economic Performance,'' signed by President Obama on October 5, 2009. 74 FR 52117, Oct. 8...

  15. 75 FR 77954 - Transfer of Federally Assisted Facility

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-14

    ... of Charlottesville (City) intends to transfer a facility and land located at 315 4th Street, NW... parcel, and is located at 315 4th Street, NW., in Charlottesville, Virginia. The building is within an...

  16. 30 CFR 254.51 - Modifying an existing OCS response plan.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... INTERIOR OFFSHORE OIL-SPILL RESPONSE REQUIREMENTS FOR FACILITIES LOCATED SEAWARD OF THE COAST LINE Oil-Spill Response Requirements for Facilities Located in State Waters Seaward of the Coast Line § 254.51...

  17. 30 CFR 254.52 - Following the format for an OCS response plan.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., DEPARTMENT OF THE INTERIOR OFFSHORE OIL-SPILL RESPONSE REQUIREMENTS FOR FACILITIES LOCATED SEAWARD OF THE COAST LINE Oil-Spill Response Requirements for Facilities Located in State Waters Seaward of the Coast...

  18. 30 CFR 254.51 - Modifying an existing OCS response plan.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... INTERIOR OFFSHORE OIL-SPILL RESPONSE REQUIREMENTS FOR FACILITIES LOCATED SEAWARD OF THE COAST LINE Oil-Spill Response Requirements for Facilities Located in State Waters Seaward of the Coast Line § 254.51...

  19. 30 CFR 254.51 - Modifying an existing OCS response plan.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... INTERIOR OFFSHORE OIL-SPILL RESPONSE REQUIREMENTS FOR FACILITIES LOCATED SEAWARD OF THE COAST LINE Oil-Spill Response Requirements for Facilities Located in State Waters Seaward of the Coast Line § 254.51...

  20. Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-96) - Snohomish District Substations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hermeston, Mark W.

    2002-07-19

    Proposed Action: Vegetation Management for facilities located in the Snohomish District. BPA proposes total vegetation management (bareground) in the electrical substations, and, noxious weed management and maintenance of landscaping within the property boundaries of the listed facilities. These facilities are all located within the Snohomish District of the Snohomish Region.

  1. Logistic regression models of factors influencing the location of bioenergy and biofuels plants

    Treesearch

    T.M. Young; R.L. Zaretzki; J.H. Perdue; F.M. Guess; X. Liu

    2011-01-01

    Logistic regression models were developed to identify significant factors that influence the location of existing wood-using bioenergy/biofuels plants and traditional wood-using facilities. Logistic models provided quantitative insight for variables influencing the location of woody biomass-using facilities. Availability of "thinnings to a basal area of 31.7m2/ha...

  2. 42 CFR 37.4 - Plans for chest roentgenographic examinations.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... name and location of the approved X-ray facility or facilities, and the approximate date(s) and time(s... shall promptly display in a visible location on the bulletin board at the mine its proposed plan or... posted in a visible location on the bulletin board until ALOSH either grants or denies approval of it at...

  3. 42 CFR 37.4 - Plans for chest roentgenographic examinations.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... name and location of the approved X-ray facility or facilities, and the approximate date(s) and time(s... shall promptly display in a visible location on the bulletin board at the mine its proposed plan or... posted in a visible location on the bulletin board until ALOSH either grants or denies approval of it at...

  4. 42 CFR 37.4 - Plans for chest roentgenographic examinations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... name and location of the approved X-ray facility or facilities, and the approximate date(s) and time(s... shall promptly display in a visible location on the bulletin board at the mine its proposed plan or... posted in a visible location on the bulletin board until ALOSH either grants or denies approval of it at...

  5. 33 CFR 154.1035 - Specific requirements for facilities that could reasonably be expected to cause significant and...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... dispersant-application platform identified. Location data must identify the distance between the platform's... product resource provider, location, and volume. Location data must include the stockpile's distance to... requirements of § 154.1045(j). (viii) For mobile facilities that operate in more than one COTP zone, the plan...

  6. 33 CFR 154.1035 - Specific requirements for facilities that could reasonably be expected to cause significant and...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... dispersant-application platform identified. Location data must identify the distance between the platform's... product resource provider, location, and volume. Location data must include the stockpile's distance to... requirements of § 154.1045(j). (viii) For mobile facilities that operate in more than one COTP zone, the plan...

  7. 33 CFR 154.1035 - Specific requirements for facilities that could reasonably be expected to cause significant and...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... dispersant-application platform identified. Location data must identify the distance between the platform's... product resource provider, location, and volume. Location data must include the stockpile's distance to... requirements of § 154.1045(j). (viii) For mobile facilities that operate in more than one COTP zone, the plan...

  8. TRI Analysis of Community-Scale Pollution Prevention Activities: North Birmingham, Alabama (PDF)

    EPA Pesticide Factsheets

    This analysis compared TRI data about pollution prevention and waste management activities from facilities located in North Birmingham with facilities in the same industry sectors that are located elsewhere in the country.

  9. 30 CFR 254.52 - Following the format for an OCS response plan.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... THE INTERIOR OFFSHORE OIL-SPILL RESPONSE REQUIREMENTS FOR FACILITIES LOCATED SEAWARD OF THE COAST LINE Oil-Spill Response Requirements for Facilities Located in State Waters Seaward of the Coast Line § 254...

  10. 30 CFR 254.52 - Following the format for an OCS response plan.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... THE INTERIOR OFFSHORE OIL-SPILL RESPONSE REQUIREMENTS FOR FACILITIES LOCATED SEAWARD OF THE COAST LINE Oil-Spill Response Requirements for Facilities Located in State Waters Seaward of the Coast Line § 254...

  11. 30 CFR 254.52 - Following the format for an OCS response plan.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... THE INTERIOR OFFSHORE OIL-SPILL RESPONSE REQUIREMENTS FOR FACILITIES LOCATED SEAWARD OF THE COAST LINE Oil-Spill Response Requirements for Facilities Located in State Waters Seaward of the Coast Line § 254...

  12. Cogeneration systems and processes for treating hydrocarbon containing formations

    DOEpatents

    Vinegar, Harold J [Bellaire, TX; Fowler, Thomas David [Houston, TX; Karanikas, John Michael [Houston, TX

    2009-12-29

    A system for treating a hydrocarbon containing formation includes a steam and electricity cogeneration facility. At least one injection well is located in a first portion of the formation. The injection well provides steam from the steam and electricity cogeneration facility to the first portion of the formation. At least one production well is located in the first portion of the formation. The production well in the first portion produces first hydrocarbons. At least one electrical heater is located in a second portion of the formation. At least one of the electrical heaters is powered by electricity from the steam and electricity cogeneration facility. At least one production well is located in the second portion of the formation. The production well in the second portion produces second hydrocarbons. The steam and electricity cogeneration facility uses the first hydrocarbons and/or the second hydrocarbons to generate electricity.

  13. Hazardous Waste Cleanup: American Standard Incorporated in Hamilton Township, New Jersey

    EPA Pesticide Factsheets

    American Standard Incorporated is located at 240 Princeton Avenue in Trenton, New Jersey. American Standard's Trenton Pottery Facility has operated at its present location since 1923. The facility manufactures ceramic plumbing fixtures using clay, plaster

  14. Executive Order 12898 and Social, Economic, and Sociopolitical Factors Influencing Toxic Release Inventory Facility Location in EPA Region 6: A Multi-Scale Spatial Assessment of Environmental Justice

    ERIC Educational Resources Information Center

    Moore, Andrea Lisa

    2013-01-01

    Toxic Release Inventory facilities are among the many environmental hazards shown to create environmental inequities in the United States. This project examined four factors associated with Toxic Release Inventory, specifically, manufacturing facility location at multiple spatial scales using spatial analysis techniques (i.e., O-ring statistic and…

  15. Accommodations for earth-viewing payloads on the international space station

    NASA Astrophysics Data System (ADS)

    Park, B.; Eppler, D. B.

    The design of the International Space Station (ISS) includes payload locations that are external to the pressurized environment. These external or attached payload accommodation locations will allow direct access to the space environment at the ISS orbit and direct viewing of the earth and space. NASA sponsored payloads will have access to several different types of standard external locations; the S3 Truss Sites, the Columbus External Payload Facility (EPF), and the Japanese Experiment Module Exposed Facility (JEM-EF). As the ISS Program develops, it may also be possible to locate external payloads at the P3 Truss Sites or at non-standard locations similar to the handrail-attached payloads that were flown during the MIR Program. Earth-viewing payloads may also be located within the pressurized volume of the US Lab in the Window Observational Research Facility (WORF). Payload accommodations at each of the locations will be described, as well as transport to and retrieval from the site.

  16. Capacitated set-covering model considering the distance objective and dependency of alternative facilities

    NASA Astrophysics Data System (ADS)

    Wayan Suletra, I.; Priyandari, Yusuf; Jauhari, Wakhid A.

    2018-03-01

    We propose a new model of facility location to solve a kind of problem that belong to a class of set-covering problem using an integer programming formulation. Our model contains a single objective function, but it represents two goals. The first is to minimize the number of facilities, and the other is to minimize the total distance of customers to facilities. The first goal is a mandatory goal, and the second is an improvement goal that is very useful when alternate optimum solutions for the first goal exist. We use a big number as a weight on the first goal to force the solution algorithm to give first priority to the first goal. Besides considering capacity constraints, our model accommodates a kind of either-or constraints representing facilities dependency. The either-or constraints will prevent the solution algorithm to select two or more facilities from the same set of facility with mutually exclusive properties. A real location selection problem to locate a set of wastewater treatment facility (IPAL) in Surakarta city, Indonesia, will describe the implementation of our model. A numerical example is given using the data of that real problem.

  17. Do drug treatment facilities increase clients' exposure to potential neighborhood-level triggers for relapse? A small-area assessment of a large, public treatment system.

    PubMed

    Jacobson, Jerry O

    2006-03-01

    Research on drug treatment facility locations has focused narrowly on the issue of geographic proximity to clients. We argue that neighborhood conditions should also enter into the facility location decision and illustrate a formal assessment of neighborhood conditions at facilities in a large, metropolitan area, taking into account conditions clients already face at home. We discuss choice and construction of small-area measures relevant to the drug treatment context, including drug activity, disadvantage, and violence as well as statistical comparisons of clients' home and treatment locations with respect to these measures. Analysis of 22,707 clients discharged from 494 community-based outpatient and residential treatment facilities that received public funds during 1998-2000 in Los Angeles County revealed no significant mean differences between home and treatment neighborhoods. However, up to 20% of clients are exposed to markedly higher levels of disadvantage, violence, or drug activity where they attend treatment than where they live, suggesting that it is not uncommon for treatment locations to increase clients' exposure to potential environmental triggers for relapse. Whereas on average both home and treatment locations exhibit higher levels of these measures than the household locations of the general population, substantial variability in public treatment clients' home neighborhoods calls into question the notion that they hail exclusively from poor, high drug activity areas. Shortcomings of measures available for neighborhood assessment of treatment locations and implications of the findings for other areas of treatment research are also discussed.

  18. A NEW, SMALL DRYING FACILITY FOR WET RADIOACTIVE WASTE AND LIQUIDS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oldiges, Olaf; Blenski, Hans-Juergen

    2003-02-27

    Due to the reason, that in Germany every Waste, that is foreseen to be stored in a final disposal facility or in a long time interim storage facility, it is necessary to treat a lot of waste using different drying technologies. In Germany two different drying facilities are in operation. The GNS Company prefers a vacuum-drying-technology and has built and designed PETRA-Drying-Facilities. In a lot of smaller locations, it is not possible to install such a facility because inside the working areas of that location, the available space to install the PETRA-Drying-Facility is too small. For that reason, GNS decidedmore » to design a new, small Drying-Facility using industrial standard components, applying the vacuum-drying-technology. The new, small Drying-Facility for wet radioactive waste and liquids is presented in this paper. The results of some tests with a prototype facility are shown in chapter 4. The main components of that new facility are described in chapter 3.« less

  19. EPA Facility Registry Service (FRS): CAMDBS

    EPA Pesticide Factsheets

    This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link to the Clean Air Markets Division Business System (CAMDBS). Administered by the EPA Clean Air Markets Division, within the Office of Air and Radiation, CAMDBS supports the implementation of market-based air pollution control programs, including the Acid Rain Program and regional programs designed to reduce the transport of ozone. FRS identifies and geospatially locates facilities, sites or places subject to environmental regulations or of environmental interest. Using vigorous verification and data management procedures, FRS integrates facility data from EPA's national program systems, other federal agencies, and State and tribal master facility records and provides EPA with a centrally managed, single source of comprehensive and authoritative information on facilities. This data set contains the subset of FRS integrated facilities that link to CAMDBS facilities once the CAMDBS data has been integrated into the FRS database. Additional information on FRS is available at the EPA website https://www.epa.gov/enviro/facility-registry-service-frs.

  20. 25 CFR 559.6 - Does a tribe need to notify the Chairman if a facility license is terminated or not renewed or if...

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... license is terminated or not renewed or if a gaming place, facility, or location closes or reopens? 559.6 Section 559.6 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR GAMING LICENSES AND... terminated or not renewed or if a gaming place, facility, or location closes or reopens? A tribe must notify...

  1. 78 FR 21344 - Grant of Authority for Subzone Status, Hemlock Semiconductor Corporation, (Polysilicon), Hemlock...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-10

    ... Status, Hemlock Semiconductor Corporation, (Polysilicon), Hemlock, Michigan Pursuant to its authority... polysilicon manufacturing facility of Hemlock Semiconductor Corporation, located in Hemlock, Michigan (FTZ... manufacturing of polysilicon at the facility of Hemlock Semiconductor Corporation, located in Hemlock, Michigan...

  2. Hazardous Waste Cleanup: GE Residential Products Incorporated in Palmer Ward, Puerto Rico

    EPA Pesticide Factsheets

    The GE Residential Products, Inc., former Caribe General Electric Products, Inc. (Caribe GE) is an electro-plating facility, located in Palmer Ward, Municipality of Rio Grande, Commonwealth of Puerto Rico. The facility is located on both sides of State

  3. ANL Critical Assembly Covariance Matrix Generation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McKnight, Richard D.; Grimm, Karl N.

    2014-01-15

    This report discusses the generation of a covariance matrix for selected critical assemblies that were carried out by Argonne National Laboratory (ANL) using four critical facilities-all of which are now decommissioned. The four different ANL critical facilities are: ZPR-3 located at ANL-West (now Idaho National Laboratory- INL), ZPR-6 and ZPR-9 located at ANL-East (Illinois) and ZPPr located at ANL-West.

  4. Photocopy of photograph (original photograph located in the Hawaii State ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Photocopy of photograph (original photograph located in the Hawaii State Archives, Admiral Furlong Collection), HAS Neg. 199.016. U.S. Navy photograph, August 21, 1919. MRS. JOSEPHUS DANIELS, WIFE OF THE SECRETARY OF THE NAVY, PUSHED A BUTTON AND DRYDOCK NO. 1 (FACILITY S779) WAS OFFICIALLY INAUGURATED. - U.S. Naval Base, Pearl Harbor, Waterfront Facilities, Various locations throughout base, Pearl City, Honolulu County, HI

  5. 42 CFR 412.534 - Special payment provisions for long-term care hospitals within hospitals and satellites of long...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... meets the criteria of § 412.22(h) from another hospital that is not the co-located hospital are made... hospital satellite facility from the co-located hospital are made under either of the following: (1) For... percent were admitted to the hospital or its satellite facility from the co-located hospital, payments are...

  6. Exposure of farm laborers and dairy cattle to formaldehyde from footbath use at a dairy farm in New York State.

    PubMed

    Doane, M; Sarenbo, S

    2014-07-15

    Formalin footbaths are commonly used in the dairy industry to prevent cattle hoof diseases. Although formalin is a well-documented disinfectant, it is also a carcinogen and irritant. The aim of this study was to estimate the exposure of farm workers and dairy cattle to formaldehyde from footbaths located in a milking facility and a heifer facility at a dairy farm in western New York, USA. The dairy farm included approximately 3900 dairy cattle including young stock; of these, 1670 cows were milked three times per day in a 60-stall carousel milking parlor, and approximately 800 heifers were located at the heifer facility where footbaths with formalin were in use. The formaldehyde concentration of the air was measured using a Formaldemeter™ htV approximately 50cm above the 3% formalin footbaths in the milking (one footbath location) and heifer (three footbath locations) facilities on three consecutive days. The measured formaldehyde concentrations varied between 0.00 and 2.28ppm, falling within the safety guidelines established by the Occupation Safety and Health Administration (OSHA) of the United States. Significant differences were found in the formaldehyde concentrations at the different footbath locations in the heifer facility, potentially due to the varying levels of ventilation at each location. Changes in the ambient temperature during the 3-day sampling period did not significantly affect the concentrations. We believe that the substantial ventilation at both the heifer and milking facilities ensured that the formaldehyde concentrations did not exceed OSHA guidelines, thus permitting the safe use of formalin footbaths in this farm. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Race, Wealth, and Solid Waste Facilities in North Carolina

    PubMed Central

    Norton, Jennifer M.; Wing, Steve; Lipscomb, Hester J.; Kaufman, Jay S.; Marshall, Stephen W.; Cravey, Altha J.

    2007-01-01

    Background Concern has been expressed in North Carolina that solid waste facilities may be disproportionately located in poor communities and in communities of color, that this represents an environmental injustice, and that solid waste facilities negatively impact the health of host communities. Objective Our goal in this study was to conduct a statewide analysis of the location of solid waste facilities in relation to community race and wealth. Methods We used census block groups to obtain racial and economic characteristics, and information on solid waste facilities was abstracted from solid waste facility permit records. We used logistic regression to compute prevalence odds ratios for 2003, and Cox regression to compute hazard ratios of facilities issued permits between 1990 and 2003. Results The adjusted prevalence odds of a solid waste facility was 2.8 times greater in block groups with ≥50% people of color compared with block groups with < 10% people of color, and 1.5 times greater in block groups with median house values < $60,000 compared with block groups with median house values ≥$100,000. Among block groups that did not have a previously permitted solid waste facility, the adjusted hazard of a new permitted facility was 2.7 times higher in block groups with ≥50% people of color compared with block groups with < 10% people of color. Conclusion Solid waste facilities present numerous public health concerns. In North Carolina solid waste facilities are disproportionately located in communities of color and low wealth. In the absence of action to promote environmental justice, the continued need for new facilities could exacerbate this environmental injustice. PMID:17805426

  8. Impact of intermodal facilities to the design of supply chains for biorefineries.

    DOT National Transportation Integrated Search

    2009-08-15

    This paper analyzes the impact that an intermodal facility has on location and transportation decisions for biofuel production plants. Location decisions impact the management of the in-bound and out-bound logistics of a plant. We model this supply c...

  9. Optimal siting of solid waste-to-value-added facilities through a GIS-based assessment.

    PubMed

    Khan, Md Mohib-Ul-Haque; Vaezi, Mahdi; Kumar, Amit

    2018-01-01

    Siting a solid waste conversion facility requires an assessment of solid waste availability as well as ensuring compliance with environmental, social, and economic factors. The main idea behind this study was to develop a methodology to locate suitable locations for waste conversion facilities considering waste availability as well as environmental and social constraints. A geographic information system (GIS) spatial analysis was used to identify the most suitable areas and to screen out unsuitable lands. The analytic hierarchy process (AHP) was used for a multi-criteria evaluation of relative preferences of different environmental and social factors. A case study was conducted for Alberta, a western province in Canada, by performing a province-wide waste availability assessment. The total available waste considered in this study was 4,077,514tonnes/year for 19 census divisions collected from 79 landfills. Finally, a location-allocation analysis was performed to determine suitable locations for 10 waste conversion facilities across the province. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Should I stay or should I go?: consistency and switching of delivery locations among new mothers in 39 Sub-Saharan African and South/Southeast Asian countries

    PubMed Central

    Benova, Lenka; Macleod, David; Radovich, Emma; Lynch, Caroline A; Campbell, Oona M R

    2017-01-01

    Abstract The objective of this article is to assess the extent and determinants of switching delivery location between women’s first and second deliveries. We used Demographic and Health Survey data from 39 low- and middle-income countries on delivery locations from >30 000 women who had their first two deliveries in the 5-year survey recall period. Each delivery was characterized as occurring at home or in a health facility, facilities were classified as public- or private-sector. The extent of switching was estimated for each country, region and overall. Multivariable logistic regression models assessed determinants of switching (home to facility or facility to home), using four dimensions (perceived/biological need, socioeconomic characteristics, utilization of care and availability of care). Overall, 49.0% of first and 44.5% of second deliveries occurred in health facilities. Among women who had their first delivery at home, 11.8% used a facility for their second (7.0% public-sector and 4.8% private-sector). Among women who had their first delivery in a facility, 21.6% switched to a home location for their second. The extent of switching varied by country; but the overall net effect was either non-existent (n = 20) or away from facilities (n = 17) in all but two countries—Cambodia and Burkina Faso. Four factors were associated with switching to a facility after a home delivery: higher education, urban residence, non-poor household status and multiple gestation. Majority of women consistently used the same delivery location for their first two deliveries. We found some evidence that where switching occurred, women were being lost from facility care during this important transition, and that all four included dimensions were important determinants of women’s pattern of delivery care use. The relative importance of these factors should be understood in each specific context to improve retention in and provision of quality intrapartum care for women and their newborns. PMID:28981668

  11. Should I stay or should I go?: consistency and switching of delivery locations among new mothers in 39 Sub-Saharan African and South/Southeast Asian countries.

    PubMed

    Benova, Lenka; Macleod, David; Radovich, Emma; Lynch, Caroline A; Campbell, Oona M R

    2017-11-01

    The objective of this article is to assess the extent and determinants of switching delivery location between women's first and second deliveries. We used Demographic and Health Survey data from 39 low- and middle-income countries on delivery locations from >30 000 women who had their first two deliveries in the 5-year survey recall period. Each delivery was characterized as occurring at home or in a health facility, facilities were classified as public- or private-sector. The extent of switching was estimated for each country, region and overall. Multivariable logistic regression models assessed determinants of switching (home to facility or facility to home), using four dimensions (perceived/biological need, socioeconomic characteristics, utilization of care and availability of care). Overall, 49.0% of first and 44.5% of second deliveries occurred in health facilities. Among women who had their first delivery at home, 11.8% used a facility for their second (7.0% public-sector and 4.8% private-sector). Among women who had their first delivery in a facility, 21.6% switched to a home location for their second. The extent of switching varied by country; but the overall net effect was either non-existent (n = 20) or away from facilities (n = 17) in all but two countries-Cambodia and Burkina Faso. Four factors were associated with switching to a facility after a home delivery: higher education, urban residence, non-poor household status and multiple gestation. Majority of women consistently used the same delivery location for their first two deliveries. We found some evidence that where switching occurred, women were being lost from facility care during this important transition, and that all four included dimensions were important determinants of women's pattern of delivery care use. The relative importance of these factors should be understood in each specific context to improve retention in and provision of quality intrapartum care for women and their newborns. © The Author 2017. Published by Oxford University Press in association with The London School of Hygiene and Tropical Medicine.

  12. Geography, facilities, and promotional strategies used to encourage indoor tanning in New York City.

    PubMed

    Brouse, Corey H; Hillyer, Grace Clarke; Basch, Charles E; Neugut, Alfred I

    2011-08-01

    There is emerging evidence for the relationship between indoor tanning and melanoma. Eighty-five indoor tanning facilities in New York City were observed to determine number of tanning machines, pricing, promotions, products, and hours. Census data by zip code was used to determine population density, gender, race, age, percent living in poverty, percent unemployed, and percent college educated of areas in which tanning facilities were located. Pricing varied by the type of machine, number of sessions purchased, and single versus bundled sessions. Facilities were located in areas that had greater population density and slightly greater median age. Compared with the zip code areas with no facilities, those with tanning facilities had a higher proportion of white residents; a lower proportion of residents living in poverty and unemployed; and a higher proportion of residents with a college education. Our data suggest that the strategic location of facilities and promotions used in NYC seek to maximize patronage by those with comparatively high levels of income and education and who may be more influenced by the social desirability of artificial tanning. Long-term interventions aimed at changing social norms regarding tan skin are needed.

  13. Human Health and Ecological Risk Assessment for the Operation of the Explosives Waste Treatment Facility at Site 300 of the Lawrence Livermore National Laboratory Volume 1: Report of Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gallegos, G; Daniels, J; Wegrecki, A

    2006-04-24

    This document contains the human health and ecological risk assessment for the Resource Recovery and Conservation Act (RCRA) permit renewal for the Explosives Waste Treatment Facility (EWTF). Volume 1 is the text of the risk assessment, and Volume 2 (provided on a compact disc) is the supporting modeling data. The EWTF is operated by the Lawrence Livermore National Laboratory (LLNL) at Site 300, which is located in the foothills between the cities of Livermore and Tracy, approximately 17 miles east of Livermore and 8 miles southwest of Tracy. Figure 1 is a map of the San Francisco Bay Area, showingmore » the location of Site 300 and other points of reference. One of the principal activities of Site 300 is to test what are known as ''high explosives'' for nuclear weapons. These are the highly energetic materials that provide the force to drive fissionable material to criticality. LLNL scientists develop and test the explosives and the integrated non-nuclear components in support of the United States nuclear stockpile stewardship program as well as in support of conventional weapons and the aircraft, mining, oil exploration, and construction industries. Many Site 300 facilities are used in support of high explosives research. Some facilities are used in the chemical formulation of explosives; others are locations where explosive charges are mechanically pressed; others are locations where the materials are inspected radiographically for such defects as cracks and voids. Finally, some facilities are locations where the machined charges are assembled before they are sent to the on-site test firing facilities, and additional facilities are locations where materials are stored. Wastes generated from high-explosives research are treated by open burning (OB) and open detonation (OD). OB and OD treatments are necessary because they are the safest methods for treating explosives wastes generated at these facilities, and they eliminate the requirement for further handling and transportation that would be required if the wastes were treated off site.« less

  14. Human Health and Ecological Risk Assessment for the Operation of the Explosives Waste Treatment Facility at Site 300 of the Lawrence Livermore National Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gallegos, G; Daniels, J; Wegrecki, A

    2007-10-01

    This document contains the human health and ecological risk assessment for the Resource Recovery and Conservation Act (RCRA) permit renewal for the Explosives Waste Treatment Facility (EWTF). Volume 1 is the text of the risk assessment, and Volume 2 (provided on a compact disc) is the supporting modeling data. The EWTF is operated by the Lawrence Livermore National Laboratory (LLNL) at Site 300, which is located in the foothills between the cities of Livermore and Tracy, approximately 17 miles east of Livermore and 8 miles southwest of Tracy. Figure 1 is a map of the San Francisco Bay Area, showingmore » the location of Site 300 and other points of reference. One of the principal activities of Site 300 is to test what are known as 'high explosives' for nuclear weapons. These are the highly energetic materials that provide the force to drive fissionable material to criticality. LLNL scientists develop and test the explosives and the integrated non-nuclear components in support of the United States nuclear stockpile stewardship program as well as in support of conventional weapons and the aircraft, mining, oil exploration, and construction industries. Many Site 300 facilities are used in support of high explosives research. Some facilities are used in the chemical formulation of explosives; others are locations where explosive charges are mechanically pressed; others are locations where the materials are inspected radiographically for such defects as cracks and voids. Finally, some facilities are locations where the machined charges are assembled before they are sent to the onsite test firing facilities, and additional facilities are locations where materials are stored. Wastes generated from high-explosives research are treated by open burning (OB) and open detonation (OD). OB and OD treatments are necessary because they are the safest methods for treating explosives wastes generated at these facilities, and they eliminate the requirement for further handling and transportation that would be required if the wastes were treated off site.« less

  15. 86. VIEW OF LIQUID NITROGEN STORAGE FACILITY LOCATED DIRECTLY WEST ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    86. VIEW OF LIQUID NITROGEN STORAGE FACILITY LOCATED DIRECTLY WEST OF THE SLC-3W FUEL APRON. NOTE HEAT EXCHANGER IN BACKGROUND. CAMERA TOWER LOCATED DIRECTLY IN FRONT OF LIQUID NITROGEN STORAGE TANK. NITROGEN AND HELIUM GAS STORAGE TANKS AT SOUTH END OF FUEL APRON IN LOWER RIGHT CORNER. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  16. EPA Facility Registry Service (FRS): TRI

    EPA Pesticide Factsheets

    This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link to the Toxic Release Inventory (TRI) System. TRI is a publicly available EPA database reported annually by certain covered industry groups, as well as federal facilities. It contains information about more than 650 toxic chemicals that are being used, manufactured, treated, transported, or released into the environment, and includes information about waste management and pollution prevention activities. FRS identifies and geospatially locates facilities, sites or places subject to environmental regulations or of environmental interest. Using vigorous verification and data management procedures, FRS integrates facility data from EPA's national program systems, other federal agencies, and State and tribal master facility records and provides EPA with a centrally managed, single source of comprehensive and authoritative information on facilities. This data set contains the subset of FRS integrated facilities that link to TRI facilities once the TRI data has been integrated into the FRS database. Additional information on FRS is available at the EPA website https://www.epa.gov/enviro/facility-registry-service-frs.

  17. 7 CFR 3570.61 - Eligibility for grant assistance

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... grant assistance The essential community facility must primarily serve rural areas, be located in a.... Essential community facilities must be: (1) Located in rural areas, except for utility-type services, such.... (d) Economic feasibility. All projects financed under the provisions of this section must be based on...

  18. 77 FR 16537 - Grant of Authority for Subzone Status Piramal Critical Care, Inc., (Inhalation Anesthetics...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-21

    ... Status Piramal Critical Care, Inc., (Inhalation Anesthetics), Bethlehem, PA Pursuant to its authority... anesthetic manufacturing and distribution facilities of Piramal Critical Care, Inc., located in Bethlehem... inhalation anesthetics at the facilities of Piramal Critical Care, Inc., located in Bethlehem, Pennsylvania...

  19. NPDES Permit for F.E. Warren Air Force Base Missile Launch Facilities in Colorado

    EPA Pesticide Factsheets

    Under NPDES permit CO-0034789, the USAF, F. E. Warren Air Force Base, is authorized to discharge from the Missile Launch Facilities located in northeastern Colorado to unnamed drainage ditches located in the Cedar Creek and Pawnee Creek drainage basins.

  20. Centralization vs. Decentralization: A Location Analysis Approach for Librarians

    ERIC Educational Resources Information Center

    Raffel, Jeffrey; Shishko, Robert

    1972-01-01

    An application of location theory to the question of centralized versus decentralized library facilities for a university, with relevance for special libraries is presented. The analysis provides models for a single library, for two or more libraries, or for decentralized facilities. (6 references) (Author/NH)

  1. Hazardous Waste Cleanup: Safety-Kleen Corporation - Congers 2-118-01 in Congers, New York

    EPA Pesticide Factsheets

    Safety-Kleen Corporation, the Congers facility is located at 68 North Harrison Avenue, Congers, Rockland County, New York. The facility is about 2,000 feet northeast of the intersection of Congers Road and Kings Highway, situated atop a small hill located

  2. Analyzing the impact of intermodal facilities to the design and management of biofuels supply chain.

    DOT National Transportation Integrated Search

    2010-01-01

    This paper analyzes the impact that an intermodal facility has on location and transportation : decisions for biofuel production plants. Location decisions impact the management of the in-bound and out-bound logistics of a plant. We model this supply...

  3. 75 FR 8920 - Grant of Authority for Subzone Status; IKEA Distribution Services (Distribution of Home...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-26

    ... Status; IKEA Distribution Services (Distribution of Home Furnishings and Accessories); Baltimore, MD... subzone at the warehouse and distribution facility of IKEA Distribution Services, located in Perryville... and distribution at the facility of IKEA Distribution Services, located in Perryville, Maryland...

  4. SOUTH ELEVATION OF IRRADIATED FUEL STORAGE FACILITY LOCATED IN FUEL ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    SOUTH ELEVATION OF IRRADIATED FUEL STORAGE FACILITY LOCATED IN FUEL STORAGE BUILDING (CPP-603). PHOTO TAKEN LOOKING NORTH. INL PHOTO NUMBER HD-54-15-2. Mike Crane, Photographer, 8/2005 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID

  5. NORTH ELEVATION OF IRRADIATED FUEL STORAGE FACILITY LOCATED IN FUEL ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    NORTH ELEVATION OF IRRADIATED FUEL STORAGE FACILITY LOCATED IN FUEL STORAGE BUILDING (CPP-603). PHOTO TAKEN LOOKING SOUTH. INL PHOTO NUMBER HD-54-16-1. Mike Crane, Photographer, 8/2005 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID

  6. 30 CFR 57.20008 - Toilet facilities.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Toilet facilities. 57.20008 Section 57.20008....20008 Toilet facilities. (a) Toilet facilities shall be provided at locations that are compatible with the mine operations and that are readily accessible to mine personnel. (b) The facilities shall be...

  7. A case study of potential human health impacts from petroleum coke transfer facilities.

    PubMed

    Dourson, Michael L; Chinkin, Lyle R; MacIntosh, David L; Finn, Jennifer A; Brown, Kathleen W; Reid, Stephen B; Martinez, Jeanelle M

    2016-11-01

    Petroleum coke or "petcoke" is a solid material created during petroleum refinement and is distributed via transfer facilities that may be located in densely populated areas. The health impacts from petcoke exposure to residents living in proximity to such facilities were evaluated for a petcoke transfer facilities located in Chicago, Illinois. Site-specific, margin of safety (MOS) and margin of exposure (MOE) analyses were conducted using estimated airborne and dermal exposures. The exposure assessment was based on a combined measurement and modeling program that included multiyear on-site air monitoring, air dispersion modeling, and analyses of soil and surfaces in residential areas adjacent to two petcoke transfer facilities located in industrial areas. Airborne particulate matter less than 10 microns (PM 10 ) were used as a marker for petcoke. Based on daily fence line monitoring, the average daily PM 10 concentration at the KCBX Terminals measured on-site was 32 μg/m 3 , with 89% of 24-hr average PM 10 concentrations below 50 μg/m 3 and 99% below 100 μg/m 3 . A dispersion model estimated that the emission sources at the KCBX Terminals produced peak PM 10 levels attributed to the petcoke facility at the most highly impacted residence of 11 μg/m 3 on an annual average basis and 54 μg/m 3 on 24-hr average basis. Chemical indicators of petcoke in soil and surface samples collected from residential neighborhoods adjacent to the facilities were equivalent to levels in corresponding samples collected at reference locations elsewhere in Chicago, a finding that is consistent with limited potential for off-site exposure indicated by the fence line monitoring and air dispersion modeling. The MOE based upon dispersion model estimates ranged from 800 to 900 for potential inhalation, the primary route of concern for particulate matter. This indicates a low likelihood of adverse health effects in the surrounding community. Implications: Handling of petroleum coke at bulk material transfer facilities has been identified as a concern for the public health of surrounding populations. The current assessment, based on measurements and modeling of two facilities located in a densely populated urban area, indicates that petcoke transport and accumulation in off-site locations is minimal. In addition, estimated human exposures, if any, are well below levels that could be anticipated to produce adverse health effects in the general population.

  8. C-431 B -- Scope document

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hollister, H.L.

    1951-06-01

    This document describes the scope of the C-431-B Reactor Production Facility. In dealing with the broad phases of the project, it includes the Sections ``A`` (Scope Modifications) of the approved Design Criteria, modified to ensure correctness to date. Location of the facility has been set as shown on the site map in HDC-2101, designated site number one. Included in Project C-431-B are the 105-C Building, including within that building facilities previously located in the 1608 Building, a contaminated effluent crib adjacent to 105-C, and gas facilities using the 115-B Building interconnected with 105-C. Also included are an oil shed, amore » thimble storage cave, a badge house, and an exclusion fence. Building services and process lines will be considered part of the project to a location nominally five feet outside of 105-C.« less

  9. A Game Theoretical Model for Location of Terror Response Facilities under Capacitated Resources

    PubMed Central

    Kang, Qi; Xu, Weisheng; Wu, Qidi

    2013-01-01

    This paper is concerned with the effect of capacity constraints on the locations of terror response facilities. We assume that the state has limited resources, and multiple facilities may be involved in the response until the demand is satisfied consequently. We formulate a leader-follower game model between the state and the terrorist and prove the existence and uniqueness of the Nash equilibrium. An integer linear programming is proposed to obtain the equilibrium results when the facility number is fixed. The problem is demonstrated by a case study of the 19 districts of Shanghai, China. PMID:24459446

  10. Hazardous Waste Cleanup: TAPI Puerto Rico Incorporated in Guayama, Puerto Rico

    EPA Pesticide Factsheets

    The TAPI facility is located on the southeastern coastal plain of Puerto Rico. The facility is about 1.1 miles north of the Caribbean Sea and 3.5 miles south of the foothills of the Cordillera Central Mountains. The Town of Guayama is located approximately

  11. Hazardous Waste Cleanup: Merial Barceloneta, LLC in Barceloneta, Puerto Rico

    EPA Pesticide Factsheets

    The Merck, Sharp & Dohme Química de Puerto Rico Ltd (MSDQ) facility is located at Road #2 km. 56.7, in the Municipality of Barceloneta, Puerto Rico. The facility is located approximately three miles south of the Atlantic Ocean and 38 miles due west of San

  12. 14 CFR 21.43 - Location of manufacturing facilities.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Location of manufacturing facilities. 21.43 Section 21.43 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT.... Except as provided in § 21.29, the Administrator does not issue a type certificate if the manufacturing...

  13. 40 CFR 125.136 - As an owner or operator of a new offshore oil and gas extraction facility, what must I collect...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... you are a fixed facility and your cooling water intake structure is located in an estuary or tidal... waterbody flow information. If your cooling water intake structure is located in an estuary or tidal river...

  14. 40 CFR 125.136 - As an owner or operator of a new offshore oil and gas extraction facility, what must I collect...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... you are a fixed facility and your cooling water intake structure is located in an estuary or tidal... waterbody flow information. If your cooling water intake structure is located in an estuary or tidal river...

  15. 40 CFR 125.136 - As an owner or operator of a new offshore oil and gas extraction facility, what must I collect...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... you are a fixed facility and your cooling water intake structure is located in an estuary or tidal... waterbody flow information. If your cooling water intake structure is located in an estuary or tidal river...

  16. 75 FR 19555 - NARA Facility Locations and Hours

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-15

    ... at 41 CFR part 101-20. The National Archives at Philadelphia on Market Street (in Philadelphia) and... NATIONAL ARCHIVES AND RECORDS ADMINISTRATION 36 CFR Parts 1200, 1253, and 1280 [FDMS Docket NARA-10-0002] RIN 3095-AB66 NARA Facility Locations and Hours AGENCY: National Archives and Records...

  17. 7 CFR 984.464 - Disposition of substandard walnuts.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... locations of the facilities within the area of production to which substandard walnuts may be shipped. The... shipped directly to an approved location where the crushing, feed manufacture, or feeding is to take place... disposition or the Board determines that substandard walnuts are not shipped to such facilities. Substandard...

  18. 7 CFR 984.464 - Disposition of substandard walnuts.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... locations of the facilities within the area of production to which substandard walnuts may be shipped. The... shipped directly to an approved location where the crushing, feed manufacture, or feeding is to take place... disposition or the Board determines that substandard walnuts are not shipped to such facilities. Substandard...

  19. 7 CFR 984.464 - Disposition of substandard walnuts.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... locations of the facilities within the area of production to which substandard walnuts may be shipped. The... shipped directly to an approved location where the crushing, feed manufacture, or feeding is to take place... disposition or the Board determines that substandard walnuts are not shipped to such facilities. Substandard...

  20. 7 CFR 984.464 - Disposition of substandard walnuts.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... locations of the facilities within the area of production to which substandard walnuts may be shipped. The... shipped directly to an approved location where the crushing, feed manufacture, or feeding is to take place... disposition or the Board determines that substandard walnuts are not shipped to such facilities. Substandard...

  1. 10 CFR 75.6 - Facility and location reporting.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 2 2010-01-01 2010-01-01 false Facility and location reporting. 75.6 Section 75.6 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) SAFEGUARDS ON NUCLEAR MATERIAL-IMPLEMENTATION OF US/IAEA..., all communications concerning the regulations in this Part shall be addressed to the U.S. Nuclear...

  2. 10 CFR 75.6 - Facility and location reporting.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 2 2013-01-01 2013-01-01 false Facility and location reporting. 75.6 Section 75.6 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) SAFEGUARDS ON NUCLEAR MATERIAL-IMPLEMENTATION OF US/IAEA..., all communications concerning the regulations in this Part shall be addressed to the U.S. Nuclear...

  3. 77 FR 3255 - Notice of 229 Boundary Revision at the Paducah Gaseous Diffusion Plant

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-23

    ... DEPARTMENT OF ENERGY Notice of 229 Boundary Revision at the Paducah Gaseous Diffusion Plant AGENCY... areas, buildings, and other facilities of the Paducah Gaseous Diffusion Plant, located in McCracken... or upon this facility, installation, or real property of the Paducah Gaseous Diffusion Plant located...

  4. 10 CFR 75.6 - Facility and location reporting.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 2 2012-01-01 2012-01-01 false Facility and location reporting. 75.6 Section 75.6 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) SAFEGUARDS ON NUCLEAR MATERIAL-IMPLEMENTATION OF US/IAEA..., all communications concerning the regulations in this Part shall be addressed to the U.S. Nuclear...

  5. 10 CFR 75.6 - Facility and location reporting.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 2 2014-01-01 2014-01-01 false Facility and location reporting. 75.6 Section 75.6 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) SAFEGUARDS ON NUCLEAR MATERIAL-IMPLEMENTATION OF US/IAEA..., all communications concerning the regulations in this Part shall be addressed to the U.S. Nuclear...

  6. 10 CFR 75.6 - Facility and location reporting.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 2 2011-01-01 2011-01-01 false Facility and location reporting. 75.6 Section 75.6 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) SAFEGUARDS ON NUCLEAR MATERIAL-IMPLEMENTATION OF US/IAEA..., all communications concerning the regulations in this Part shall be addressed to the U.S. Nuclear...

  7. 14 CFR 21.309 - Location of or change to manufacturing facilities.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Location of or change to manufacturing facilities. 21.309 Section 21.309 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT CERTIFICATION PROCEDURES FOR PRODUCTS AND PARTS Approval of Materials, Parts, Processes...

  8. 10 CFR 960.5-2-9 - Rock characteristics.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ..., or location of an underground facility. (2) In situ characteristics and conditions that could require... undue hazard to personnel; and (3) the requirements specified in § 960.5-1(a)(3) can be met. (b... significant flexibility in selecting the depth, configuration, and location of the underground facility. (2) A...

  9. 10 CFR 960.5-2-9 - Rock characteristics.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ..., or location of an underground facility. (2) In situ characteristics and conditions that could require... undue hazard to personnel; and (3) the requirements specified in § 960.5-1(a)(3) can be met. (b... significant flexibility in selecting the depth, configuration, and location of the underground facility. (2) A...

  10. 10 CFR 960.5-2-9 - Rock characteristics.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ..., or location of an underground facility. (2) In situ characteristics and conditions that could require... undue hazard to personnel; and (3) the requirements specified in § 960.5-1(a)(3) can be met. (b... significant flexibility in selecting the depth, configuration, and location of the underground facility. (2) A...

  11. 30 CFR 254.42 - Exercises for your response personnel and equipment.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ..., DEPARTMENT OF THE INTERIOR OFFSHORE OIL-SPILL RESPONSE REQUIREMENTS FOR FACILITIES LOCATED SEAWARD OF THE... facility or at a corporate location designated in the plan. Records showing that OSRO's and oil spill...) An annual spill management team tabletop exercise. The exercise must test the spill management team's...

  12. 30 CFR 254.42 - Exercises for your response personnel and equipment.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ..., DEPARTMENT OF THE INTERIOR OFFSHORE OIL-SPILL RESPONSE REQUIREMENTS FOR FACILITIES LOCATED SEAWARD OF THE... facility or at a corporate location designated in the plan. Records showing that OSRO's and oil spill...) An annual spill management team tabletop exercise. The exercise must test the spill management team's...

  13. 30 CFR 56.20008 - Toilet facilities.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Toilet facilities. 56.20008 Section 56.20008... Toilet facilities. (a) Toilet facilities shall be provided at locations that are compatible with the mine operations and that are readily accessible to mine personnel. (b) The facilities shall be kept clean and...

  14. EPA Facility Registry Service (FRS): RCRA

    EPA Pesticide Factsheets

    This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of hazardous waste facilities that link to the Resource Conservation and Recovery Act Information System (RCRAInfo). EPA's comprehensive information system in support of the Resource Conservation and Recovery Act (RCRA) of 1976 and the Hazardous and Solid Waste Amendments (HSWA) of 1984, RCRAInfo tracks many types of information about generators, transporters, treaters, storers, and disposers of hazardous waste. FRS identifies and geospatially locates facilities, sites or places subject to environmental regulations or of environmental interest. Using vigorous verification and data management procedures, FRS integrates facility data from EPA's national program systems, other federal agencies, and State and tribal master facility records and provides EPA with a centrally managed, single source of comprehensive and authoritative information on facilities. This data set contains the subset of FRS integrated facilities that link to RCRAInfo hazardous waste facilities once the RCRAInfo data has been integrated into the FRS database. Additional information on FRS is available at the EPA website https://www.epa.gov/enviro/facility-registry-service-frs

  15. 20 CFR 416.1023 - Facilities.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 20 Employees' Benefits 2 2010-04-01 2010-04-01 false Facilities. 416.1023 Section 416.1023... Facilities. (a) Space, equipment, supplies, and other services. Subject to appropriate Federal funding, the... and prompt disability determinations. (b) Location of facilities. Subject to appropriate Federal...

  16. Contrasting O/X-mode Heater Effects on O-Mode Sounding echo and the Generation of Magnetic Pulsations

    DTIC Science & Technology

    2010-01-06

    Micropulsation [10] The induced magnetic field variation was monitored by the fluxgate magnetometer located at Gakona, AK. The 1 sec resolution data...minutes on and 1 minute off, were explored. The experiments were monitored using the digisonde and magnetometer located at the HAARP facility. The...were explored. The experiments were monitored using the digisonde and magnetometer located at the HAARP facility. The results show that the

  17. Overview of Opportunities for Co-Location of Solar Energy Technologies and Vegetation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Macknick, Jordan; Beatty, Brenda; Hill, Graham

    2013-12-01

    Large-scale solar facilities have the potential to contribute significantly to national electricity production. Many solar installations are large-scale or utility-scale, with a capacity over 1 MW and connected directly to the electric grid. Large-scale solar facilities offer an opportunity to achieve economies of scale in solar deployment, yet there have been concerns about the amount of land required for solar projects and the impact of solar projects on local habitat. During the site preparation phase for utility-scale solar facilities, developers often grade land and remove all vegetation to minimize installation and operational costs, prevent plants from shading panels, and minimizemore » potential fire or wildlife risks. However, the common site preparation practice of removing vegetation can be avoided in certain circumstances, and there have been successful examples where solar facilities have been co-located with agricultural operations or have native vegetation growing beneath the panels. In this study we outline some of the impacts that large-scale solar facilities can have on the local environment, provide examples of installations where impacts have been minimized through co-location with vegetation, characterize the types of co-location, and give an overview of the potential benefits from co-location of solar energy projects and vegetation. The varieties of co-location can be replicated or modified for site-specific use at other solar energy installations around the world. We conclude with opportunities to improve upon our understanding of ways to reduce the environmental impacts of large-scale solar installations.« less

  18. 14 CFR 171.271 - Installation requirements.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ...) NAVIGATIONAL FACILITIES NON-FEDERAL NAVIGATION FACILITIES Interim Standard Microwave Landing System (ISMLS) § 171.271 Installation requirements. (a) The ISMLS facility must be permanent in nature, located... codes, FCC licensing requirements, and paragraphs (a) and (c) of § 171.261. (b) The ISMLS facility must...

  19. 14 CFR 171.271 - Installation requirements.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ...) NAVIGATIONAL FACILITIES NON-FEDERAL NAVIGATION FACILITIES Interim Standard Microwave Landing System (ISMLS) § 171.271 Installation requirements. (a) The ISMLS facility must be permanent in nature, located... codes, FCC licensing requirements, and paragraphs (a) and (c) of § 171.261. (b) The ISMLS facility must...

  20. 14 CFR 171.271 - Installation requirements.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ...) NAVIGATIONAL FACILITIES NON-FEDERAL NAVIGATION FACILITIES Interim Standard Microwave Landing System (ISMLS) § 171.271 Installation requirements. (a) The ISMLS facility must be permanent in nature, located... codes, FCC licensing requirements, and paragraphs (a) and (c) of § 171.261. (b) The ISMLS facility must...

  1. 20 CFR 404.1623 - Facilities.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 20 Employees' Benefits 2 2010-04-01 2010-04-01 false Facilities. 404.1623 Section 404.1623...- ) Determinations of Disability Administrative Responsibilities and Requirements § 404.1623 Facilities. (a) Space... determinations. (b) Location of facilities. Subject to appropriate Federal funding, the State will determine the...

  2. Region 9 NPDES Outfalls 2012

    EPA Pesticide Factsheets

    Point geospatial dataset representing locations of NPDES outfalls/dischargers for facilities which generally represent the site of the discharge. NPDES (National Pollution Discharge Elimination System) is an EPA permit program that regulates direct discharges from treated waste water that is discharged into waters of the US. Facilities are issued NPDES permits regulating their discharge as required by the Clean Water Act. A facility may have one or more dischargers. The location represents the discharge point of a discrete conveyance such as a pipe or man made ditch.

  3. Technical Basis Document for Internal Dosimetry at Sandia National Laboratories Revision 2.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Potter, Charles A.

    2014-09-01

    The RPID Project will be implemented at all SNL facilities for activities involving the processing and/or storing of radioactive materials. This project includes activities at the Tech Area (TA) I, TA II, TA III, TA IV, TA V, Coyote Test Field, and environmental restoration sites at SNL, located in Albuquerque, New Mexico, and the Kauai Test Facility(SNL/KTF). Reference to SNL throughout this document includes facilities and activities at the Albuquerque location and at SNL/KTF.

  4. Welcome to NNIN | National Nanotechnology Infrastructure Network

    Science.gov Websites

    ALD system located at the Stanford Nanofabrication Facility, one of the 14 NNIN nodes. NNIN facilities facilities such as this CVD furnace at the Cornell facility. Student using one of the scanning electron microscopes at the Howard University NNIN facility. This is one of over 1100 major instruments available

  5. 25 CFR 502.23 - Facility license.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 25 Indians 2 2010-04-01 2010-04-01 false Facility license. 502.23 Section 502.23 Indians NATIONAL....23 Facility license. Facility license means a separate license issued by a tribe to each place, facility, or location on Indian lands where the tribe elects to allow class II or III gaming. [73 FR 6029...

  6. Optimal Facility Location Tool for Logistics Battle Command (LBC)

    DTIC Science & Technology

    2015-08-01

    64 Appendix B. VBA Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 Appendix C. Story...should city planners have located emergency service facilities so that all households (the demand) had equal access to coverage?” The critical...programming language called Visual Basic for Applications ( VBA ). CPLEX is a commercial solver for linear, integer, and mixed integer linear programming problems

  7. 78 FR 9884 - Approval of Subzone Status; Zimmer Manufacturing BV; Ponce, Puerto Rico

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-12

    ...; Zimmer Manufacturing BV; Ponce, Puerto Rico Pursuant to its authority under the Foreign-Trade Zones Act... subzone at the facility of Zimmer Manufacturing BV located in Ponce, Puerto Rico (FTZ Docket B-81-2012... hereby approves subzone status at the facility of Zimmer Manufacturing BV located in Ponce, Puerto Rico...

  8. 25 CFR 559.7 - May the Chairman request Indian lands or environmental and public health and safety documentation...

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... and public health and safety documentation regarding any gaming place, facility, or location where... environmental and public health and safety documentation regarding any gaming place, facility, or location where gaming will occur? A tribe shall provide Indian lands or environmental and public health and safety...

  9. Predicting site locations for biomass using facilities with Bayesian methods

    Treesearch

    Timothy M. Young; James H. Perdue; Xia Huang

    2017-01-01

    Logistic regression models combined with Bayesian inference were developed to predict locations and quantify factors that influence the siting of biomass-using facilities that use woody biomass in the Southeastern United States. Predictions were developed for two groups of mills, one representing larger capacity mills similar to pulp and paper mills (Group II...

  10. 76 FR 87 - Grant of Authority for Subzone Status; Skechers USA, LLC (Distribution of Footwear); Moreno...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-03

    ... Status; Skechers USA, LLC (Distribution of Footwear); Moreno Valley, California Pursuant to its authority... distribution facility of Skechers USA, LLC, located in Moreno Valley, California, (FTZ Docket 5- 2008, filed 2... activity related to footwear warehousing and distribution at the facility of Skechers USA, LLC, located in...

  11. Site survey for optimum location of Optical Communication Experimental Facility

    NASA Technical Reports Server (NTRS)

    1968-01-01

    Site survey was made to determine the optimum location for an Optical Communication Experimental Facility /OCEF/ and to recommend several sites, graded according to preference. A site was desired which could perform two-way laser communication with a spacecraft and laser tracking with a minimum of interruption by weather effects.

  12. 75 FR 8921 - Grant of Authority for Subzone Status; Brightpoint North America L.P. (Cell Phone Kitting and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-26

    ... Status; Brightpoint North America L.P. (Cell Phone Kitting and Distribution) Indianapolis, IN Pursuant to... the cell phone kitting and distribution facilities of Brightpoint North America L.P., located in... cell phones at the facilities of Brightpoint North America L.P., located in Plainfield, Indiana...

  13. 25 CFR 559.7 - May the Chairman request Indian lands or environmental and public health and safety documentation...

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... and public health and safety documentation regarding any gaming place, facility, or location where... environmental and public health and safety documentation regarding any gaming place, facility, or location where gaming will occur? A tribe shall provide Indian lands or environmental and public health and safety...

  14. 25 CFR 559.7 - May the Chairman request Indian lands or environmental and public health and safety documentation...

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... and public health and safety documentation regarding any gaming place, facility, or location where... environmental and public health and safety documentation regarding any gaming place, facility, or location where gaming will occur? A tribe shall provide Indian lands or environmental and public health and safety...

  15. Facility Detection and Popularity Assessment from Text Classification of Social Media and Crowdsourced Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sparks, Kevin A; Li, Roger G; Thakur, Gautam

    Advances in technology have continually progressed our understanding of where people are, how they use the environment around them, and why they are at their current location. Having a better knowledge of when various locations become popular through space and time could have large impacts on research fields like urban dynamics and energy consumption. In this paper, we discuss the ability to identify and locate various facility types (e.g. restaurant, airport, stadiums) using social media, and assess methods in determining when these facilities become popular over time. We use natural language processing tools and machine learning classifiers to interpret geotaggedmore » Twitter text and determine if a user is seemingly at a location of interest when the tweet was sent. On average our classifiers are approximately 85% accurate varying across multiple facility types, with a peak precision of 98%. By using these methods to classify unstructured text, geotagged social media data can be an extremely useful tool to better understanding the composition of places and how and when people use them.« less

  16. 15 CFR 807.1 - Public Reference Facility.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ...) BUREAU OF ECONOMIC ANALYSIS, DEPARTMENT OF COMMERCE PUBLIC INFORMATION § 807.1 Public Reference Facility. The Public Reference Facility of the Bureau of Economic Analysis is located in room B7 of the Tower...

  17. 15 CFR 807.1 - Public Reference Facility.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ...) BUREAU OF ECONOMIC ANALYSIS, DEPARTMENT OF COMMERCE PUBLIC INFORMATION § 807.1 Public Reference Facility. The Public Reference Facility of the Bureau of Economic Analysis is located in room B7 of the Tower...

  18. 15 CFR 807.1 - Public Reference Facility.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ...) BUREAU OF ECONOMIC ANALYSIS, DEPARTMENT OF COMMERCE PUBLIC INFORMATION § 807.1 Public Reference Facility. The Public Reference Facility of the Bureau of Economic Analysis is located in room B7 of the Tower...

  19. US EPA Region 4 RMP Facilities

    EPA Pesticide Factsheets

    To improve public health and the environment, the United States Environmental Protection Agency (USEPA) collects information about facilities, sites, or places subject to environmental regulation or of environmental interest. Through the Geospatial Data Download Service, the public is now able to download the EPA Geodata shapefile containing facility and site information from EPA's national program systems. The file is Internet accessible from the Envirofacts Web site (http://www.epa.gov/enviro). The data may be used with geospatial mapping applications. (Note: The shapefile omits facilities without latitude/longitude coordinates.) The EPA Geospatial Data contains the name, location (latitude/longitude), and EPA program information about specific facilities and sites. In addition, the file contains a Uniform Resource Locator (URL), which allows mapping applications to present an option to users to access additional EPA data resources on a specific facility or site.

  20. Estimates of Radioxenon Released from Southern Hemisphere Medical isotope Production Facilities Using Measured Air Concentrations and Atmospheric Transport Modeling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eslinger, Paul W.; Friese, Judah I.; Lowrey, Justin D.

    2014-09-01

    Abstract The International Monitoring System (IMS) of the Comprehensive-Nuclear-Test-Ban-Treaty monitors the atmosphere for radioactive xenon leaking from underground nuclear explosions. Emissions from medical isotope production represent a challenging background signal when determining whether measured radioxenon in the atmosphere is associated with a nuclear explosion prohibited by the treaty. The Australian Nuclear Science and Technology Organisation (ANSTO) operates a reactor and medical isotope production facility in Lucas Heights, Australia. This study uses two years of release data from the ANSTO medical isotope production facility and Xe-133 data from three IMS sampling locations to estimate the annual releases of Xe-133 from medicalmore » isotope production facilities in Argentina, South Africa, and Indonesia. Atmospheric dilution factors derived from a global atmospheric transport model were used in an optimization scheme to estimate annual release values by facility. The annual releases of about 6.8×1014 Bq from the ANSTO medical isotope production facility are in good agreement with the sampled concentrations at these three IMS sampling locations. Annual release estimates for the facility in South Africa vary from 1.2×1016 to 2.5×1016 Bq and estimates for the facility in Indonesia vary from 6.1×1013 to 3.6×1014 Bq. Although some releases from the facility in Argentina may reach these IMS sampling locations, the solution to the objective function is insensitive to the magnitude of those releases.« less

  1. Cleanups In My Community (CIMC) - Federal facilities that are also Superfund sites, National Layer

    EPA Pesticide Factsheets

    Federal facilities are properties owned by the federal government. This data layer provides access to Federal facilities that are Superfund sites as part of the CIMC web service. Data are collected using the Superfund Enterprise Management System (SEMS) and transferred to Envirofacts for access by the public. Data about Federal facility Superfund sites are located on their own EPA web pages, and CIMC links to those pages. Links to the relevant web pages for each site are provided within the attribute table. Federal facility sites can be either Superfund sites or RCRA Corrective Action sites, or they may have moved from one program to the other and back. In Cleanups in My Community, you can map or list any of these Federal Facility sites. This data layer shows only those facilities that are Superfund Sites. RCRA federal facility sites and other Superfund NPL sites are included in other data layers as part of this web service.Superfund is a program administered by the EPA to locate, investigate, and clean up worst hazardous waste sites throughout the United States. EPA administers the Superfund program in cooperation with individual states and tribal governments. These sites include abandoned warehouses, manufacturing facilities, processing plants, and landfills - the key word here being abandoned. The CIMC web service was initially published in 2013, but the data are updated on the 18th of each month. The full schedule for data updates in CIMC is located here:

  2. Environmental impact statement Space Shuttle advanced solid rocket motor program

    NASA Technical Reports Server (NTRS)

    1989-01-01

    The proposed action is design, development, testing, and evaluation of Advanced Solid Rocket Motors (ASRM) to replace the motors currently used to launch the Space Shuttle. The proposed action includes design, construction, and operation of new government-owned, contractor-operated facilities for manufacturing and testing the ASRM's. The proposed action also includes transport of propellant-filled rocket motor segments from the manufacturing facility to the testing and launch sites and the return of used and/or refurbished segments to the manufacturing site. Sites being considered for the new facilities include John C. Stennis Space Center, Hancock County, Mississippi; the Yellow Creek site in Tishomingo County, Mississippi, which is currently in the custody and control of the Tennessee Valley Authority; and John F. Kennedy Space Center, Brevard County, Florida. TVA proposes to transfer its site to the custody and control of NASA if it is the selected site. All facilities need not be located at the same site. Existing facilities which may provide support for the program include Michoud Assembly Facility, New Orleans Parish, Louisiana; and Slidell Computer Center, St. Tammany Parish, Louisiana. NASA's preferred production location is the Yellow Creek site, and the preferred test location is the Stennis Space Center.

  3. Capacity planning for electronic waste management facilities under uncertainty: multi-objective multi-time-step model development.

    PubMed

    Poonam Khanijo Ahluwalia; Nema, Arvind K

    2011-07-01

    Selection of optimum locations for locating new facilities and decision regarding capacities at the proposed facilities is a major concern for municipal authorities/managers. The decision as to whether a single facility is preferred over multiple facilities of smaller capacities would vary with varying priorities to cost and associated risks such as environmental or health risk or risk perceived by the society. Currently management of waste streams such as that of computer waste is being done using rudimentary practices and is flourishing as an unorganized sector, mainly as backyard workshops in many cities of developing nations such as India. Uncertainty in the quantification of computer waste generation is another major concern due to the informal setup of present computer waste management scenario. Hence, there is a need to simultaneously address uncertainty in waste generation quantities while analyzing the tradeoffs between cost and associated risks. The present study aimed to address the above-mentioned issues in a multi-time-step, multi-objective decision-support model, which can address multiple objectives of cost, environmental risk, socially perceived risk and health risk, while selecting the optimum configuration of existing and proposed facilities (location and capacities).

  4. Operations Plans for Anadromous Fish Production Facilities in the Columbia River Basin, Volume II of V; 1992 Annual Report.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hutchison, Bill

    1993-05-01

    Clearwater Hatchery is located on the north bank of the North Fork of the Clearwater River, downstream from Dworshak Dam. It is approximately 72 miles from Lower Granite Dam, and 504 miles from the mouth of the Columbia River. Site elevation is approximately 994 feet above sea level. The hatchery is staffed with 7 FTE's. Clearwater Hatchery has two pipelines from Dworshak Reservoir. One is attached to a floating platform and is capable of providing various temperatures at varying depths. The other is a stationary intake about 245 feet below the top of the dam. All water is gravity fedmore » to the hatchery. An l8 inch intake pipe provides an estimated 10 cfs with temperature remaining constant at approximately 40 F. The primary 42-inch intake pipe can draw water from 5 to 45 feet in depth with temperatures ranging from 55 to 60 F and 70 cfs of flow. The hatchery facility consists of 11 chinook raceways, 24 steelhead raceways, 2 adult holding ponds, a covered spawning area with 2 live wells and 60 concrete rearing vats. There are 40 double stacks of Heath-type incubators and each vat also has an incubation jar. All facility units are in excellent condition. Clearwater Hatchery also supports satellite facilities at Red River, Crooked River and Powell. The Red River satellite facility is located approximately 15 miles east of Elk City, Idaho. It is approximately 186 miles upstream from Lower Granite Dam and 618 miles from the mouth of the Columbia River. It was first built in 1974 by the Columbia River Project and then remodeled by the U.S. Army Corps of Engineers in 1986. Red River is supplied by gravity flow from an intake located at the bottom of the South Fork of Red River, 225 yards upstream from the facility. Water rights allow for 10 cfs and during low flows in the summer about 5 cfs is available. Temperatures range from 40 F in the spring to 71 F in early August. The facility consists of two adult holding ponds, a removable tripod and panel weir, and a rearing pond. All units are in good condition due to the recent remodeling. The Crooked River satellite facility is located 20 miles downstream of Red River. The trap is located 0.5 miles upstream of the mouth of Crooked River, a tributary of the South Fork of the Clearwater River. The rearing ponds are 10 miles upstream from the Crooked River adult trap. Crooked River water is supplied by gravity flow by an intake 200 yards upstream of the facility raceways. Water rights allow for 10 cfs at the rearing facility and 10 cfs at the trapping facility. Water temperatures range from 42 to 70 F. The trap and weir are located at the mouth of Crooked River. Ten miles upstream from the mouth are two raceways, a cleaning waste pond and final settling pond. All facility units are in good condition. The Powell satellite facility is located 122 miles east of the Clear-water Hatchery at the headwaters of the Lochsa River, the confluence of the Crooked Fork Creek and White Sands Creek. Powell is 192.5 miles from Lower Granite Dam and 624 miles from the mouth of the Columbia River. The Powell Facility receives gravity flow water from Walton Creek at a rate of 7 cfs with the intake being located 100 yards upstream from the facility. Powell also has a pumped supply from White Sands Creek at 3 cfs. Water temperature ranges from 45.8 to 50.2 F from the Walton Creek intake and 41 to 65 F from the White Sands pump station. The facility consists of one rearing pond, a diversion and intake screen, two adult holding ponds, a floating weir, and an open bay spawning shelter. All facility units are in good condition.« less

  5. 9 CFR 307.1 - Facilities for Program employees.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... INSPECTION AND CERTIFICATION FACILITIES FOR INSPECTION § 307.1 Facilities for Program employees. Office space... employees assigned thereto. The space set aside for this purpose shall meet with approval of the circuit... facilities exist in a nearby convenient location. Laundry service for inspectors' outer work clothing shall...

  6. Planning and Equipping Industrial Arts Facilities.

    ERIC Educational Resources Information Center

    Maine State Dept. of Educational and Cultural Services, Augusta. Bureau of Vocational Education.

    Architectural details, planning, and facility guidelines for industrial arts facilities are given, with data on planning the number, shape, size, and location of school shops. Industrial art programing and performance criteria for varying levels of education are discussed with regard for the different shop curriculums. The facility planning is…

  7. 14 CFR 171.327 - Operational records.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ...) NAVIGATIONAL FACILITIES NON-FEDERAL NAVIGATION FACILITIES Microwave Landing System (MLS) § 171.327 Operational... operational records at the indicated time to the appropriate FAA regional office where the facility is located... facility and two copies must be sent to the appropriate FAA regional office. The owner or his maintenance...

  8. 14 CFR 171.327 - Operational records.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ...) NAVIGATIONAL FACILITIES NON-FEDERAL NAVIGATION FACILITIES Microwave Landing System (MLS) § 171.327 Operational... operational records at the indicated time to the appropriate FAA regional office where the facility is located... facility and two copies must be sent to the appropriate FAA regional office. The owner or his maintenance...

  9. Grid Facilities | Grid Modernization | NREL

    Science.gov Websites

    groundbreaking innovations and collaboration in grid research. Photo of the Energy Systems Integration Facility Energy Systems Integration Facility The Energy Systems Integration Facility is the nation's premier user Located in Boulder, Colorado, the National Wind Technology Center (NWTC) offers similar integration

  10. Optimally Stationing Army Forces

    DTIC Science & Technology

    2008-12-01

    the force draw down. Military Oper. Res. 2(4) 39–51. Owen, S., M. Daskin . 1998. Strategic facility location: A review. Eur. J. Oper. Res. 111 423–447...ReVelle, C., H. Eiselt. 2005. Location analysis: A synthesis and sur- vey. Eur. J. Oper. Res. 165 1–19. ReVelle, C., H. Eiselt, M. Daskin . 2008. A ...National Guard, and Army Reserve soldiers. The Army assigns each soldier to a unit at one of over 4,000 worldwide locations; these facilities consist of

  11. 3718-F Alkali Metal Treatment and Storage Facility Closure Plan. Revision 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    The Hanford Site, located northwest of the city of Richland, Washington, houses reactors, chemical-separation systems, and related facilities used for the production of special nuclear materials, as well as for activities associated with nuclear energy development. The 300 Area of the Hanford Site contains reactor fuel manufacturing facilities and several research and development laboratories. The 3718-F Alkali Metal Treatment and Storage Facility (3718-F Facility), located in the 300 Area, was used to store and treat alkali metal wastes. Therefore, it is subject to the regulatory requirements for the storage and treatment of dangerous wastes. Closure will be conducted pursuant tomore » the requirements of the Washington Administrative Code (WAC) 173-303-610 (Ecology 1989) and 40 CFR 270.1. Closure also will satisfy the thermal treatment facility closure requirements of 40 CFR 265.381. This closure plan presents a description of the 3718-F Facility, the history of wastes managed, and the approach that will be followed to close the facility. Only hazardous constituents derived from 3718-F Facility operations will be addressed.« less

  12. Analysis of selected materials flown on interior locations of the Long Duration Exposure Facility

    NASA Technical Reports Server (NTRS)

    Smith, H. A.; Nelson, K. M.; Eash, D.; Pippin, H. G.

    1994-01-01

    This report documents the post-flight condition of selected hardware taken from interior locations on the Long Duration Exposure Facility (LDEF). This hardware was generally in excellent condition. Outgassing data is presented for heat shrink tubing and fiberglass composite shims. Variation in total mass loss (TML) values for heat shrink tubing were correlated with location. Nylon grommets were evaluated for mechanical integrity; slight embrittlement was observed for flight specimens. Multi-layer insulation blankets, wire bundles, and paints in non-exposed interior locations were all in visibly good condition. Silicon-containing contaminant films were observed on silver-coated hex nuts at the space- and Earth-end interior locations.

  13. African Braille Production: A Statistical Review and Evaluation of Countries and Costs.

    ERIC Educational Resources Information Center

    Mayer, Marc; Cylke, Frank Kurt

    A study was conducted in 52 African countries to determine the extent of braille facilities for the blind, with the aim of choosing a location for a central braille producing facility. To make the selection, the factors of ease of communication (i.e., central location), political stability, and extent of already existing organizations for the…

  14. Optimal Facility-Location

    PubMed Central

    Goldman, A. J.

    2006-01-01

    Dr. Christoph Witzgall, the honoree of this Symposium, can count among his many contributions to applied mathematics and mathematical operations research a body of widely-recognized work on the optimal location of facilities. The present paper offers to non-specialists a sketch of that field and its evolution, with emphasis on areas most closely related to Witzgall’s research at NBS/NIST. PMID:27274920

  15. 75 FR 12732 - Foreign-Trade Zones 73 and 74; Application for Manufacturing Authority; The Belt's Corporation...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-17

    ...; Application for Manufacturing Authority; The Belt's Corporation (Kitting of Liquor Gift Sets); Elkridge and...,000 unit gift set capacity) is located within Site 3 in Elkridge, Maryland. The facility in FTZ 74 (36 employees, 674,159 unit gift set capacity) is located within Site 13 in Baltimore, Maryland. The facilities...

  16. 77 FR 58470 - Irradiation Treatment; Location of Facilities in the Southern United States; Technical Amendment

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-21

    .... APHIS-2009-0100] RIN 0579-AD35 Irradiation Treatment; Location of Facilities in the Southern United... things, allow for irradiation treatment of mangoes from India upon arrival in the mainland United States... 20, 2012, we amended the regulations in Sec. 319.56-46 to allow for irradiation treatment of mangoes...

  17. 77 FR 60715 - Information Collection Activities: Oil-Spill Response Requirements for Facilities Located Seaward...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-04

    ... Section 311 of the Federal Water Pollution Control Act of October 18, 1972, as Amended, and the Oil... Facilities Located Seaward of the Coast Line. OMB Control Number: 1014-0007. Abstract: The Federal Water Pollution Control Act, as amended by the Oil Pollution Act of 1990 (OPA), requires that a spill-response...

  18. 30 CFR 254.27 - What information must I include in the “Dispersant use plan” appendix?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... ENFORCEMENT, DEPARTMENT OF THE INTERIOR OFFSHORE OIL-SPILL RESPONSE REQUIREMENTS FOR FACILITIES LOCATED SEAWARD OF THE COAST LINE Oil-Spill Response Plans for Outer Continental Shelf Facilities § 254.27 What... location of the dispersants and other chemical or biological products which you might use on the oils...

  19. 30 CFR 254.27 - What information must I include in the “Dispersant use plan” appendix?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... ENFORCEMENT, DEPARTMENT OF THE INTERIOR OFFSHORE OIL-SPILL RESPONSE REQUIREMENTS FOR FACILITIES LOCATED SEAWARD OF THE COAST LINE Oil-Spill Response Plans for Outer Continental Shelf Facilities § 254.27 What... location of the dispersants and other chemical or biological products which you might use on the oils...

  20. 30 CFR 254.27 - What information must I include in the “Dispersant use plan” appendix?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... ENFORCEMENT, DEPARTMENT OF THE INTERIOR OFFSHORE OIL-SPILL RESPONSE REQUIREMENTS FOR FACILITIES LOCATED SEAWARD OF THE COAST LINE Oil-Spill Response Plans for Outer Continental Shelf Facilities § 254.27 What... location of the dispersants and other chemical or biological products which you might use on the oils...

  1. 30 CFR 75.1712-7 - Underground sanitary facilities; waiver of requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Underground sanitary facilities; waiver of... § 75.1712-7 Underground sanitary facilities; waiver of requirements. If it has been determined by the... application by the operator, waive the location requirements for underground sanitary facilities with respect...

  2. 30 CFR 75.1712-7 - Underground sanitary facilities; waiver of requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Underground sanitary facilities; waiver of... § 75.1712-7 Underground sanitary facilities; waiver of requirements. If it has been determined by the... application by the operator, waive the location requirements for underground sanitary facilities with respect...

  3. 30 CFR 75.1712-7 - Underground sanitary facilities; waiver of requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Underground sanitary facilities; waiver of... § 75.1712-7 Underground sanitary facilities; waiver of requirements. If it has been determined by the... application by the operator, waive the location requirements for underground sanitary facilities with respect...

  4. 30 CFR 75.1712-7 - Underground sanitary facilities; waiver of requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Underground sanitary facilities; waiver of... § 75.1712-7 Underground sanitary facilities; waiver of requirements. If it has been determined by the... application by the operator, waive the location requirements for underground sanitary facilities with respect...

  5. 30 CFR 75.1712-7 - Underground sanitary facilities; waiver of requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Underground sanitary facilities; waiver of... § 75.1712-7 Underground sanitary facilities; waiver of requirements. If it has been determined by the... application by the operator, waive the location requirements for underground sanitary facilities with respect...

  6. 76 FR 40945 - Rensselaer Polytechnic Institute Critical Experiments Facility; Notice of Issuance of Renewed...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-12

    ... NUCLEAR REGULATORY COMMISSION [Docket No. 50-225; NRC-2008-0277] Rensselaer Polytechnic Institute Critical Experiments Facility; Notice of Issuance of Renewed Facility Operating License No. CX-22 The U.S... of the Rensselaer Polytechnic Institute Critical Experiments Facility (RCF), located in Schenectady...

  7. NPDES Permit for Riverview Estates Wastewater Treatment Facility in North Dakota

    EPA Pesticide Factsheets

    Under National Pollutant Discharge Elimination System permit number ND-0031143, the Riverview Estates Wastewater Treatment Facility is authorized to discharge from its wastewater treatment facility in designated locations as described in the permit.

  8. 40 CFR 63.3081 - Am I subject to this subpart?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... is located at a plastic or composites molding facility; (ii) All of the body parts topcoated at your....) at your facility or at another plastic or composites molding facility which you own or operate, and...

  9. Network Performance Evaluation Model for assessing the impacts of high-occupancy vehicle facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Janson, B.N.; Zozaya-Gorostiza, C.; Southworth, F.

    1986-09-01

    A model to assess the impacts of major high-occupancy vehicle (HOV) facilities on regional levels of energy consumption and vehicle air pollution emissions in urban aeas is developed and applied. This model can be used to forecast and compare the impacts of alternative HOV facility design and operation plans on traffic patterns, travel costs, model choice, travel demand, energy consumption and vehicle emissions. The model is designed to show differences in the overall impacts of alternative HOV facility types, locations and operation plans rather than to serve as a tool for detailed engineering design and traffic planning studies. The Networkmore » Performance Evaluation Model (NETPEM) combines several urban transportation planning models within a multi-modal network equilibrium framework including modules with which to define the type, location and use policy of the HOV facility to be tested, and to assess the impacts of this facility.« less

  10. US EPA Region 4 Brownfields

    EPA Pesticide Factsheets

    To improve public health and the environment, the United States Environmental Protection Agency (USEPA) collects information about facilities, sites, or places subject to environmental regulation or of environmental interest. Through the Geospatial Data Download Service, the public is now able to download the EPA Geodata shapefile containing facility and site information from EPA's national program systems. The file is Internet accessible from the Envirofacts Web site (https://www3.epa.gov/enviro/). The data may be used with geospatial mapping applications. (Note: The shapefile omits facilities without latitude/longitude coordinates.) The EPA Geospatial Data contains the name, location (latitude/longitude), and EPA program information about specific facilities and sites. In addition, the file contains a Uniform Resource Locator (URL), which allows mapping applications to present an option to users to access additional EPA data resources on a specific facility or site. This dataset shows Brownfields listed in the 2012 Facility Registry System.

  11. A Versatile Rocket Engine Hot Gas Facility

    NASA Technical Reports Server (NTRS)

    Green, James M.

    1993-01-01

    The capabilities of a versatile rocket engine facility, located in the Rocket Laboratory at the NASA Lewis Research Center, are presented. The gaseous hydrogen/oxygen facility can be used for thermal shock and hot gas testing of materials and structures as well as rocket propulsion testing. Testing over a wide range of operating conditions in both fuel and oxygen rich regimes can be conducted, with cooled or uncooled test specimens. The size and location of the test cell provide the ability to conduct large amounts of testing in short time periods with rapid turnaround between programs.

  12. Western Aeronautical Test Range

    NASA Technical Reports Server (NTRS)

    Sakahara, Robert D.

    2008-01-01

    This viewgraph presentation reviews the work of the Western Aeronautical Test Range (WATR). NASA's Western Aeronautical Test Range is a network of facilities used to support aeronautical research, science missions, exploration system concepts, and space operations. The WATR resides at NASA's Dryden Flight Research Center located at Edwards Air Force Base, California. The WATR is a part of NASA's Corporate Management of Aeronautical Facilities and funded by the Strategic Capability Asset Program (SCAP). Maps show the general location of the WATR area that is used for aeronautical testing and evaluation. The products, services and facilities of WATR are discussed,

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Loftin, B.; Abramczyk, G.; Koenig, R.

    Radioactive materials are stored in a variety of locations throughout the DOE complex. At the Savannah River Site (SRS), materials are stored within dedicated facilities. Each of those facilities has a documented safety analysis (DSA) that describes accidents that the facility and the materials within it may encounter. Facilities at the SRS are planning on utilizing the certified Model 9977 Shipping Package as a long term storage package and one of these facilities required ballistics testing. Specifically, in order to meet the facility DSA, the radioactive materials (RAM) must be contained within the storage package after impact by a .223more » caliber round. In order to qualify the Model 9977 Shipping Package for storage in this location, the package had to be tested under these conditions. Over the past two years, the Model 9977 Shipping Package has been subjected to a series of ballistics tests. The purpose of the testing was to determine if the 9977 would be suitable for use as a storage package at a Savannah River Site facility. The facility requirements are that the package must not release any of its contents following the impact in its most vulnerable location by a .223 caliber round. A package, assembled to meet all of the design requirements for a certified 9977 shipping configuration and using simulated contents, was tested at the Savannah River Site in March of 2011. The testing was completed and the package was examined. The results of the testing and examination are presented in this paper.« less

  14. Ground-water hydrology of Dugway Proving Ground and adjoining area, Tooele and Juab counties, Utah

    USGS Publications Warehouse

    Steiger, Judy I.; Freethey, Geoffrey W.

    2001-01-01

    Dugway Proving Ground (DPG) is a U.S. Department of Defense chemical, biological, and explosives testing facility in northwestern Utah.  The facility includes about 620 mi2 in Tooele County.  The town of Dugway, referred to as English Village, is the administrative headquarters for the military facility, the primary residential area, and community center.  The English Village area is located at the southern end of Skull Valley and is separated from the Fries area by a surface-water divide.  Most of the facility is located just to the west of Skull Valley in Government Creek Valley, Dugway Valley, and the Great Salt Lake Desert (fig. 1).

  15. Advanced Post-Irradiation Examination Capabilities Alternatives Analysis Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jeff Bryan; Bill Landman; Porter Hill

    2012-12-01

    An alternatives analysis was performed for the Advanced Post-Irradiation Capabilities (APIEC) project in accordance with the U.S. Department of Energy (DOE) Order DOE O 413.3B, “Program and Project Management for the Acquisition of Capital Assets”. The Alternatives Analysis considered six major alternatives: ? No Action ? Modify Existing DOE Facilities – capabilities distributed among multiple locations ? Modify Existing DOE Facilities – capabilities consolidated at a few locations ? Construct New Facility ? Commercial Partnership ? International Partnerships Based on the alternatives analysis documented herein, it is recommended to DOE that the advanced post-irradiation examination capabilities be provided by amore » new facility constructed at the Materials and Fuels Complex at the Idaho National Laboratory.« less

  16. NIMBY, CLAMP, and the location of new nuclear-related facilities: U.S. national and 11 site-specific surveys.

    PubMed

    Greenberg, Michael R

    2009-09-01

    Public and political opposition have made finding locations for new nuclear power plants, waste management, and nuclear research and development facilities a challenge for the U.S. government and the nuclear industry. U.S. government-owned properties that already have nuclear-related activities and commercial nuclear power generating stations are logical locations. Several studies and utility applications to the Nuclear Regulatory Commission suggest that concentrating locations at major plants (CLAMP) has become an implicit siting policy. We surveyed 2,101 people who lived within 50 miles of 11 existing major nuclear sites and 600 who lived elsewhere in the United States. Thirty-four percent favored CLAMP for new nuclear power plants, 52% for waste management facilities, and 50% for new nuclear laboratories. College educated, relatively affluent male whites were the strongest CLAMP supporters. They disproportionately trusted those responsible for the facilities and were not worried about existing nuclear facilities or other local environmental issues. Notably, they were concerned about continuing coal use. Not surprisingly, CLAMP proponents tended to be familiar with their existing local nuclear site. In short, likely CLAMP sites have a large and politically powerful core group to support a CLAMP policy. The challenge to proponents of nuclear technologies will be to sustain this support and expand the base among those who clearly are less connected and receptive to new nearby sites.

  17. Reagan Test Site Distributed Operations

    DTIC Science & Technology

    2012-01-01

    for missile testing because of its geography and its strategic location in the Pacific [ 1 ]. The atoll’s distance from launch facilities at Vandenberg...research on ballistic missile defense 50 years ago (Figure 1 ). The subsequent development of RTS’s unique instrumentation sensors, including high...control center including hardware, software, networks, and the facility functioned successfully. FIGURE 1 . The map shows the isolated location of the

  18. 47 CFR 90.607 - Supplemental information to be furnished by applicants for facilities under this subpart.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... the location of the base station transmitter site of the facility for which they have applied. (2... licensed to them within 64 km (40 mi.) from the location of the base station transmitter site of the... control stations to be placed in operation within the term of the license. (c) [Reserved] (d) All...

  19. Medical Surveillance Monthly Report (MSMR). Volume 14, Number 8, December 2007

    DTIC Science & Technology

    2007-12-01

    the brown recluse spider; installations in Florida, Georgia, Indiana, Iowa, Nebraska, New Mexico , North Carolina, Ohio, South Carolina, and West...facility. Shigella Hepatitis B Varicella Reporting locations Number of reports all events† Food-borne Vaccine preventable Campylo- bacter Giardia...reporting vary by facility. Shigella Hepatitis B Varicella Reporting locations Number of reports all events† Food-borne Vaccine preventable Campylo

  20. 75 FR 35865 - Self-Regulatory Organizations; Notice of Filing of Proposed Rule Change by NYSE Amex LLC Amending...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-23

    ... the New York Stock Exchange LLC (``NYSE''). See SR-NYSE-2010-43. Background Round lot interest on the... legacy trading systems and facilities located at 86 Trinity Place, New York, New York, to trading systems and facilities located at 11 Wall Street, New York, New York (the ``Equities Relocation'') on December...

  1. Sports Facilities, Shopping Centers or Homes: What Locations are Important for Adults' Physical Activity? A Cross-Sectional Study.

    PubMed

    Jansen, Marijke; Ettema, Dick; Pierik, Frank; Dijst, Martin

    2016-03-04

    Physical activity (PA) is influenced by the built environment. However, little is known about the types of built environment where adults spend their time, and at what levels of PA they engage in those environments. Understanding the effect of the built environment on PA requires insight into PA behavior at different types of locations (e.g., home, work, shopping centers, and sports facilities). Therefore, this study describes where adults aged 45-65 years were active with moderate-to-vigorous intensity (MVPA), and examines associations of socio-demographic factors and neighborhood with MVPA at these locations. Participants' (N = 308) PA was measured for seven days using accelerometers and GPS-devices. Adults spent most minutes of MVPA at home and work. Highest MVPA-ratios of total time spent at a location were achieved in sports facilities and during transport. Neighborhood characteristics and socio-demographic factors such as work status, health status and household structure, had significant effects on MVPA at various locations and on total MVPA. Understanding PA behavior at various locations may provide insights that allow professionals in different domains (e.g., health, landscaping, urban planning) to develop strategies to stimulate PA.

  2. Sports Facilities, Shopping Centers or Homes: What Locations are Important for Adults’ Physical Activity? A Cross-Sectional Study

    PubMed Central

    Jansen, Marijke; Ettema, Dick; Pierik, Frank; Dijst, Martin

    2016-01-01

    Physical activity (PA) is influenced by the built environment. However, little is known about the types of built environment where adults spend their time, and at what levels of PA they engage in those environments. Understanding the effect of the built environment on PA requires insight into PA behavior at different types of locations (e.g., home, work, shopping centers, and sports facilities). Therefore, this study describes where adults aged 45–65 years were active with moderate-to-vigorous intensity (MVPA), and examines associations of socio-demographic factors and neighborhood with MVPA at these locations. Participants’ (N = 308) PA was measured for seven days using accelerometers and GPS-devices. Adults spent most minutes of MVPA at home and work. Highest MVPA-ratios of total time spent at a location were achieved in sports facilities and during transport. Neighborhood characteristics and socio-demographic factors such as work status, health status and household structure, had significant effects on MVPA at various locations and on total MVPA. Understanding PA behavior at various locations may provide insights that allow professionals in different domains (e.g., health, landscaping, urban planning) to develop strategies to stimulate PA. PMID:26959041

  3. Western Canada study of animal health effects associated with exposure to emissions from oil and natural gas field facilities. Study design and data collection II. Location of study herds relative to the oil and gas industry in Western Canada.

    PubMed

    Waldner, Cheryl L

    2008-01-01

    During the late part of 2000 and early months of 2001, project veterinarians recruited 205 beef herds to participate in a study of the effects of emissions from the upstream oil and gas industry on cattle reproduction and health. Researchers developed herd-selection criteria to optimize the range of exposure to facilities, including oil and gas wells, battery sites, and gas-gathering and gas-processing facilities across the major cattle-producing areas of Western Canada. Herds were initially selected on the basis of a ranking system of exposure potential on the basis of herd-owner reports of the locations of their operations in relation to oil and gas industry facilities. At the end of the study, researchers summarized data obtained from provincial regulatory agencies on facility location and reported flaring and venting volumes for each herd and compared these data to the original rankings of herd-exposure potential. Through this selection process, the researchers were successful in obtaining statistically significant differences in exposure to various types of oil and gas facility types and reported emissions among herds recruited for the study.

  4. 5 CFR 2604.201 - Public reading room facility and Web site.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 5 Administrative Personnel 3 2011-01-01 2011-01-01 false Public reading room facility and Web site... DISCLOSURE REPORTS FOIA Public Reading Room Facility and Web Site; Index Identifying Information for the Public § 2604.201 Public reading room facility and Web site. (a)(1) Location of public reading room...

  5. 5 CFR 2604.201 - Public reading room facility and Web site.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 5 Administrative Personnel 3 2010-01-01 2010-01-01 false Public reading room facility and Web site... DISCLOSURE REPORTS FOIA Public Reading Room Facility and Web Site; Index Identifying Information for the Public § 2604.201 Public reading room facility and Web site. (a)(1) Location of public reading room...

  6. 75 FR 54025 - Vessel and Facility Response Plans for Oil: 2003 Removal Equipment Requirements and Alternative...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-03

    ...-AA26 Vessel and Facility Response Plans for Oil: 2003 Removal Equipment Requirements and Alternative... a final rule entitled ``Vessel and Facility Response Plans for Oil: 2003 Removal Equipment... responders for each vessel or facility with appropriate equipment and resources located in each zone of...

  7. 30 CFR 254.3 - May I cover more than one facility in my response plan?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ..., DEPARTMENT OF THE INTERIOR OFFSHORE OIL-SPILL RESPONSE REQUIREMENTS FOR FACILITIES LOCATED SEAWARD OF THE... Plans must address all the elements required for a response plan in Subpart B, Oil Spill Response Plans for Outer Continental Shelf Facilities, or Subpart D, Oil Spill Response Requirements for Facilities...

  8. 30 CFR 254.3 - May I cover more than one facility in my response plan?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., DEPARTMENT OF THE INTERIOR OFFSHORE OIL-SPILL RESPONSE REQUIREMENTS FOR FACILITIES LOCATED SEAWARD OF THE... Plans must address all the elements required for a response plan in Subpart B, Oil Spill Response Plans for Outer Continental Shelf Facilities, or Subpart D, Oil Spill Response Requirements for Facilities...

  9. 30 CFR 254.3 - May I cover more than one facility in my response plan?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ..., DEPARTMENT OF THE INTERIOR OFFSHORE OIL-SPILL RESPONSE REQUIREMENTS FOR FACILITIES LOCATED SEAWARD OF THE... Plans must address all the elements required for a response plan in Subpart B, Oil Spill Response Plans for Outer Continental Shelf Facilities, or Subpart D, Oil Spill Response Requirements for Facilities...

  10. Data Acquisition System Architecture and Capabilities At NASA GRC Plum Brook Station's Space Environment Test Facilities

    NASA Technical Reports Server (NTRS)

    Evans, Richard K.; Hill, Gerald M.

    2012-01-01

    Very large space environment test facilities present unique engineering challenges in the design of facility data systems. Data systems of this scale must be versatile enough to meet the wide range of data acquisition and measurement requirements from a diverse set of customers and test programs, but also must minimize design changes to maintain reliability and serviceability. This paper presents an overview of the common architecture and capabilities of the facility data acquisition systems available at two of the world?s largest space environment test facilities located at the NASA Glenn Research Center?s Plum Brook Station in Sandusky, Ohio; namely, the Space Propulsion Research Facility (commonly known as the B-2 facility) and the Space Power Facility (SPF). The common architecture of the data systems is presented along with details on system scalability and efficient measurement systems analysis and verification. The architecture highlights a modular design, which utilizes fully-remotely managed components, enabling the data systems to be highly configurable and support multiple test locations with a wide-range of measurement types and very large system channel counts.

  11. Data Acquisition System Architecture and Capabilities at NASA GRC Plum Brook Station's Space Environment Test Facilities

    NASA Technical Reports Server (NTRS)

    Evans, Richard K.; Hill, Gerald M.

    2014-01-01

    Very large space environment test facilities present unique engineering challenges in the design of facility data systems. Data systems of this scale must be versatile enough to meet the wide range of data acquisition and measurement requirements from a diverse set of customers and test programs, but also must minimize design changes to maintain reliability and serviceability. This paper presents an overview of the common architecture and capabilities of the facility data acquisition systems available at two of the world's largest space environment test facilities located at the NASA Glenn Research Center's Plum Brook Station in Sandusky, Ohio; namely, the Space Propulsion Research Facility (commonly known as the B-2 facility) and the Space Power Facility (SPF). The common architecture of the data systems is presented along with details on system scalability and efficient measurement systems analysis and verification. The architecture highlights a modular design, which utilizes fully-remotely managed components, enabling the data systems to be highly configurable and support multiple test locations with a wide-range of measurement types and very large system channel counts.

  12. Towards a global network of gamma-ray detector calibration facilities

    NASA Astrophysics Data System (ADS)

    Tijs, Marco; Koomans, Ronald; Limburg, Han

    2016-09-01

    Gamma-ray logging tools are applied worldwide. At various locations, calibration facilities are used to calibrate these gamma-ray logging systems. Several attempts have been made to cross-correlate well known calibration pits, but this cross-correlation does not include calibration facilities in Europe or private company calibration facilities. Our aim is to set-up a framework that gives the possibility to interlink all calibration facilities worldwide by using `tools of opportunity' - tools that have been calibrated in different calibration facilities, whether this usage was on a coordinated basis or by coincidence. To compare the measurement of different tools, it is important to understand the behaviour of the tools in the different calibration pits. Borehole properties, such as diameter, fluid, casing and probe diameter strongly influence the outcome of gamma-ray borehole logging. Logs need to be properly calibrated and compensated for these borehole properties in order to obtain in-situ grades or to do cross-hole correlation. Some tool providers provide tool-specific correction curves for this purpose. Others rely on reference measurements against sources of known radionuclide concentration and geometry. In this article, we present an attempt to set-up a framework for transferring `local' calibrations to be applied `globally'. This framework includes corrections for any geometry and detector size to give absolute concentrations of radionuclides from borehole measurements. This model is used to compare measurements in the calibration pits of Grand Junction, located in the USA; Adelaide (previously known as AMDEL), located in Adelaide Australia; and Stonehenge, located at Medusa Explorations BV in the Netherlands.

  13. Factors Influencing Health Facility Delivery in Predominantly Rural Communities across the Three Ecological Zones in Ghana: A Cross-Sectional Study

    PubMed Central

    Enuameh, Yeetey Akpe Kwesi; Okawa, Sumiyo; Asante, Kwaku Poku; Kikuchi, Kimiyo; Mahama, Emmanuel; Ansah, Evelyn; Tawiah, Charlotte; Adjei, Kwame; Shibanuma, Akira; Nanishi, Keiko; Yeji, Francis; Agyekum, Enoch Oti; Yasuoka, Junko; Gyapong, Margaret; Oduro, Abraham Rexford; Quansah Asare, Gloria; Hodgson, Abraham; Jimba, Masamine; Owusu-Agyei, Seth

    2016-01-01

    Background Maternal and neonatal mortality indicators remain high in Ghana and other sub-Saharan African countries. Both maternal and neonatal health outcomes improve when skilled personnel provide delivery services within health facilities. Determinants of delivery location are crucial to promoting health facility deliveries, but little research has been done on this issue in Ghana. This study explored factors influencing delivery location in predominantly rural communities in Ghana. Methods Data were collected from 1,500 women aged 15–49 years with live or stillbirths that occurred between January 2011 and April 2013. This was done within the three sites operating Health and Demographic Surveillance Systems, i.e., the Dodowa (Greater Accra Region), Kintampo (Brong Ahafo Region), and Navrongo (Upper-East Region) Health Research Centers in Ghana. Multivariable logistic regression was used to identify the determinants of delivery location, controlling for covariates that were statistically significant in univariable regression models. Results Of 1,497 women included in the analysis, 75.6% of them selected health facilities as their delivery location. After adjusting for confounders, the following factors were associated with health facility delivery across all three sites: healthcare provider’s influence on deciding health facility delivery, (AOR = 13.47; 95% CI 5.96–30.48), place of residence (AOR = 4.49; 95% CI 1.14–17.68), possession of a valid health insurance card (AOR = 1.90; 95% CI 1.29–2.81), and socio-economic status measured by wealth quintiles (AOR = 2.83; 95% CI 1.43–5.60). Conclusion In addition to known factors such as place of residence, socio-economic status, and possession of valid health insurance, this study identified one more factor associated with health facility delivery: healthcare provider’s influence. Ensuring care provider’s counseling of clients could improve the uptake of health facility delivery in rural communities in Ghana. PMID:27031301

  14. A Benders based rolling horizon algorithm for a dynamic facility location problem

    DOE PAGES

    Marufuzzaman,, Mohammad; Gedik, Ridvan; Roni, Mohammad S.

    2016-06-28

    This study presents a well-known capacitated dynamic facility location problem (DFLP) that satisfies the customer demand at a minimum cost by determining the time period for opening, closing, or retaining an existing facility in a given location. To solve this challenging NP-hard problem, this paper develops a unique hybrid solution algorithm that combines a rolling horizon algorithm with an accelerated Benders decomposition algorithm. Extensive computational experiments are performed on benchmark test instances to evaluate the hybrid algorithm’s efficiency and robustness in solving the DFLP problem. Computational results indicate that the hybrid Benders based rolling horizon algorithm consistently offers high qualitymore » feasible solutions in a much shorter computational time period than the standalone rolling horizon and accelerated Benders decomposition algorithms in the experimental range.« less

  15. Earthquake effects at nuclear reactor facilities: San Fernando earthquake of February 9th, 1971

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Howard, G.; Ibanez, P.; Matthiesen, F.

    1972-02-01

    The effects of the San Fernando earthquake of February 9, 1971 on 26 reactor facilities located in California, Arizona, and Nevada are reported. The safety performance of the facilities during the earthquake is discussed. (JWR)

  16. 6. Photocopy of engineering drawing. AETR DIGS FACILITY THEODOLITE AND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. Photocopy of engineering drawing. AETR DIGS FACILITY THEODOLITE AND PRISM SHELTER: MONUMENT LOCATION AND LINE-OF-SIGHT PLAN, 1972. - Cape Canaveral Air Station, Launch Complex 17, Facility 28413, East end of Lighthouse Road, Cape Canaveral, Brevard County, FL

  17. 40 CFR 265.55 - Emergency coordinator.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... FACILITIES Contingency Plan and Emergency Procedures § 265.55 Emergency coordinator. At all times, there must... aspects of the facility's contingency plan, all operations and activities at the facility, the location... out the contingency plan. [Comment: The emergency coordinator's responsibilities are more fully...

  18. Methods and Systems for Advanced Spaceport Information Management

    NASA Technical Reports Server (NTRS)

    Fussell, Ronald M. (Inventor); Ely, Donald W. (Inventor); Meier, Gary M. (Inventor); Halpin, Paul C. (Inventor); Meade, Phillip T. (Inventor); Jacobson, Craig A. (Inventor); Blackwell-Thompson, Charlie (Inventor)

    2007-01-01

    Advanced spaceport information management methods and systems are disclosed. In one embodiment, a method includes coupling a test system to the payload and transmitting one or more test signals that emulate an anticipated condition from the test system to the payload. One or more responsive signals are received from the payload into the test system and are analyzed to determine whether one or more of the responsive signals comprises an anomalous signal. At least one of the steps of transmitting, receiving, analyzing and determining includes transmitting at least one of the test signals and the responsive signals via a communications link from a payload processing facility to a remotely located facility. In one particular embodiment, the communications link is an Internet link from a payload processing facility to a remotely located facility (e.g. a launch facility, university, etc.).

  19. Methods and systems for advanced spaceport information management

    NASA Technical Reports Server (NTRS)

    Ely, Donald W. (Inventor); Fussell, Ronald M. (Inventor); Halpin, Paul C. (Inventor); Blackwell-Thompson, Charlie (Inventor); Meier, Gary M. (Inventor); Meade, Phillip T. (Inventor); Jacobson, Craig A. (Inventor)

    2007-01-01

    Advanced spaceport information management methods and systems are disclosed. In one embodiment, a method includes coupling a test system to the payload and transmitting one or more test signals that emulate an anticipated condition from the test system to the payload. One or more responsive signals are received from the payload into the test system and are analyzed to determine whether one or more of the responsive signals comprises an anomalous signal. At least one of the steps of transmitting, receiving, analyzing and determining includes transmitting at least one of the test signals and the responsive signals via a communications link from a payload processing facility to a remotely located facility. In one particular embodiment, the communications link is an Internet link from a payload processing facility to a remotely located facility (e.g. a launch facility, university, etc.).

  20. Development of an Integrated Leachate Treatment Solution for the Port Granby Waste Management Facility - 12429

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Conroy, Kevin W.; Vandergaast, Gerald

    2012-07-01

    The Port Granby Project (the Project) is located near the north shore of Lake Ontario in the Municipality of Clarington, Ontario, Canada. The Project consists of relocating approximately 450,000 m{sup 3} of historic Low-Level Radioactive Waste (LLRW) and contaminated soil from the existing Port Granby Waste Management Facility (WMF) to a proposed Long-Term Waste Management Facility (LTWMF) located adjacent to the WMF. The LTWMF will include an engineered waste containment facility, a Wastewater Treatment Plant (WTP), and other ancillary facilities. A series of bench- and pilot-scale test programs have been conducted to identify preferred treatment processes to be incorporated intomore » the WTP to treat wastewater generated during the construction, closure and post-closure periods at the WMF/LTWMF. (authors)« less

  1. R4FRS_RCRAINFO

    EPA Pesticide Factsheets

    To improve public health and the environment, the United States Environmental Protection Agency (USEPA) collects information about facilities, sites, or places subject to environmental regulation or of environmental interest. Through the Geospatial Data Download Service, the public is now able to download the EPA Geodata shapefile containing facility and site information from EPA's national program systems. The file is Internet accessible from the Envirofacts Web site (http://www.epa.gov/enviro). The data may be used with geospatial mapping applications. (Note: The shapefile omits facilities without latitude/longitude coordinates.) The EPA Geospatial Data contains the name, location (latitude/longitude), and EPA program information about specific facilities and sites. In addition, the file contains a Uniform Resource Locator (URL), which allows mapping applications to present an option to users to access additional EPA data resources on a specific facility or site.

  2. EPA Facility Registry Service (FRS): PCS_NPDES

    EPA Pesticide Factsheets

    This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link to the Permit Compliance System (PCS) or the National Pollutant Discharge Elimination System (NPDES) module of the Integrated Compliance Information System (ICIS). PCS tracks NPDES surface water permits issued under the Clean Water Act. This system is being incrementally replaced by the NPDES module of ICIS. Under NPDES, all facilities that discharge pollutants from any point source into waters of the United States are required to obtain a permit. The permit will likely contain limits on what can be discharged, impose monitoring and reporting requirements, and include other provisions to ensure that the discharge does not adversely affect water quality. FRS identifies and geospatially locates facilities, sites or places subject to environmental regulations or of environmental interest. Using vigorous verification and data management procedures, FRS integrates facility data from EPA's national program systems, other federal agencies, and State and tribal master facility records and provides EPA with a centrally managed, single source of comprehensive and authoritative information on facilities. This data set contains the subset of FRS integrated facilities that link to NPDES facilities once the PCS or ICIS-NPDES data has been integrated into the FRS database. Additional information on FRS is available

  3. Astronomic Telescope Facility: Preliminary systems definition study report. Volume 2: Technical description

    NASA Technical Reports Server (NTRS)

    Sobeck, Charlie (Editor)

    1987-01-01

    The Astrometric Telescope Facility (AFT) is to be an earth-orbiting facility designed specifically to measure the change in relative position of stars. The primary science investigation for the facility will be the search for planets and planetary systems outside the solar system. In addition the facility will support astrophysics investigations dealing with the location or motions of stars. The science objective and facility capabilities for astrophysics investigations are discussed.

  4. Location | FNLCR Staging

    Cancer.gov

    The Frederick National Laboratory for Cancer Research campus is located 50 miles northwest of Washington, D.C., and 50 miles west of Baltimore, Maryland, in Frederick, Maryland. Satellite locations include leased and government facilities extending s

  5. A Probabilistic, Facility-Centric Approach to Lightning Strike Location

    NASA Technical Reports Server (NTRS)

    Huddleston, Lisa L.; Roeder, William p.; Merceret, Francis J.

    2012-01-01

    A new probabilistic facility-centric approach to lightning strike location has been developed. This process uses the bivariate Gaussian distribution of probability density provided by the current lightning location error ellipse for the most likely location of a lightning stroke and integrates it to determine the probability that the stroke is inside any specified radius of any location, even if that location is not centered on or even with the location error ellipse. This technique is adapted from a method of calculating the probability of debris collisionith spacecraft. Such a technique is important in spaceport processing activities because it allows engineers to quantify the risk of induced current damage to critical electronics due to nearby lightning strokes. This technique was tested extensively and is now in use by space launch organizations at Kennedy Space Center and Cape Canaveral Air Force Station. Future applications could include forensic meteorology.

  6. EPA Facility Registry Service (FRS): ICIS

    EPA Pesticide Factsheets

    This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link to the Integrated Compliance Information System (ICIS). When complete, ICIS will provide a database that will contain integrated enforcement and compliance information across most of EPA's programs. The vision for ICIS is to replace EPA's independent databases that contain enforcement data with a single repository for that information. Currently, ICIS contains all Federal Administrative and Judicial enforcement actions and a subset of the Permit Compliance System (PCS), which supports the National Pollutant Discharge Elimination System (NPDES). ICIS exchanges non-sensitive enforcement/compliance activities, non-sensitive formal enforcement actions and NPDES information with FRS. This web feature service contains the enforcement/compliance activities and formal enforcement action related facilities; the NPDES facilities are contained in the PCS_NPDES web feature service. FRS identifies and geospatially locates facilities, sites or places subject to environmental regulations or of environmental interest. Using vigorous verification and data management procedures, FRS integrates facility data from EPA's national program systems, other federal agencies, and State and tribal master facility records and provides EPA with a centrally managed, single source of comprehensive and authoritative information on f

  7. SSC OCIO, IT SUMMIT 2011

    NASA Technical Reports Server (NTRS)

    Cottrell, Dinna L.

    2011-01-01

    The Stennis Space Center (SSC) Records Retention Facility is a centralized location for all SSC records, Records Management staff, and the SSC History Office. The building is a storm resistant facility and provides a secure environment for records housing. The Records Retention Facility was constructed in accordance with The National Archives and Records Administration (NARA) requirements for records storage, making it the first NARA compliant facility in the agency. Stennis Space Center's Records Retention Facility became operational in May 2010. The SSC Records Retention Facility ensures that the required federal records are preserved, managed and accessible to all interested personnel. The facility provides 20,000 cubic feet of records storage capacity for the purpose of managing the centers consolidated records within a central, protected environment. Records housed in the facility are in the form of paper, optical, film and magnetic media. Located within the SSC Records Retention Facility, the Records Management Office provides comprehensive records management services in the form of: a) Storage and life-cycle management of inactive records of all media types; b) Digitizing/scanning of records and documents; c) Non-textual/digital electronic records media storage, migration and transfer; d) Records Remediation.

  8. Hazardous Waste Cleanup: Sabic Innovative Plastics US, LLC in Selkirk, New York

    EPA Pesticide Factsheets

    The ownership of the facility was transferred from General Electric to Sabic Innovative Plastics in May 2007. The facility is located on Noryl Avenue in the town of Selkirk. The facility is approximately six miles from the Hudson River.

  9. ATLAS with CARIBU: A laboratory portrait

    DOE PAGES

    Pardo, Richard C.; Savard, Guy; Janssens, Robert V. F.

    2016-03-21

    The Argonne Tandem Linac Accelerator System (ATLAS) is the world's first superconducting accelerator for projectiles heavier than the electron. This unique system is a U.S. Department of Energy (DOE) national user research facility open to scientists from all over the world. Here, it is located within the Physics Division at Argonne National Laboratory and is one of five large scientific user facilities located at the laboratory.

  10. BIOLOGICAL IRRADIATION FACILITY

    DOEpatents

    McCorkle, W.H.; Cern, H.S.

    1962-04-24

    A facility for irradiating biological specimens with neutrons is described. It includes a reactor wherein the core is off center in a reflector. A high-exposure room is located outside the reactor on the side nearest the core while a low-exposure room is located on the opposite side. Means for converting thermal neutrons to fast neutrons are movably disposed between the reactor core and the high and low-exposure rooms. (AEC)

  11. 42 CFR 83.13 - How will NIOSH evaluate petitions, other than petitions by claimants covered under § 83.14?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., consistent with the findings of the analysis discussed under paragraph (c)(1) of this section? NIOSH will... class: facility, job titles, duties, and/or specific work locations at the facility, the relevant time... employed the class; (ii) The job titles and/or job duties and/or work locations of class members; (iii) The...

  12. Next generation gamma-ray Cherenkov detectors for the National Ignition Facility.

    PubMed

    Herrmann, H W; Kim, Y H; McEvoy, A M; Zylstra, A B; Young, C S; Lopez, F E; Griego, J R; Fatherley, V E; Oertel, J A; Stoeffl, W; Khater, H; Hernandez, J E; Carpenter, A; Rubery, M S; Horsfield, C J; Gales, S; Leatherland, A; Hilsabeck, T; Kilkenny, J D; Malone, R M; Hares, J D; Milnes, J; Shmayda, W T; Stoeckl, C; Batha, S H

    2016-11-01

    The newest generation of Gas Cherenkov Detector (GCD-3) employed in Inertial Confinement Fusion experiments at the Omega Laser Facility has provided improved performance over previous generations. Comparison of reaction histories measured using two different deuterium-tritium fusion products, namely gamma rays using GCD and neutrons using Neutron Temporal Diagnostic (NTD), have provided added credibility to both techniques. GCD-3 is now being brought to the National Ignition Facility (NIF) to supplement the existing Gamma Reaction History (GRH-6m) located 6 m from target chamber center (TCC). Initially it will be located in a reentrant well located 3.9 m from TCC. Data from GCD-3 will inform the design of a heavily-shielded "Super" GCD to be located as close as 20 cm from TCC. It will also provide a test-bed for faster optical detectors, potentially lowering the temporal resolution from the current ∼100 ps state-of-the-art photomultiplier tubes (PMT) to ∼10 ps Pulse Dilation PMT technology currently under development.

  13. Locations and attributes of utility-scale solar power facilities in Colorado and New Mexico, 2011

    USGS Publications Warehouse

    Ignizio, Drew A.; Carr, Natasha B.

    2012-01-01

    The data series consists of polygonal boundaries for utility-scale solar power facilities (both photovoltaic and concentrating solar power) located within Colorado and New Mexico as of December 2011. Attributes captured for each facility include the following: facility name, size/production capacity (in MW), type of solar technology employed, location, state, operational status, year the facility came online, and source identification information. Facility locations and perimeters were derived from 1-meter true-color aerial photographs (2011) produced by the National Agriculture Imagery Program (NAIP); the photographs have a positional accuracy of about ±5 meters (accessed from the NAIP GIS service: http://gis.apfo.usda.gov/arcgis/services). Solar facility perimeters represent the full extent of each solar facility site, unless otherwise noted. When visible, linear features such as fences or road lines were used to delineate the full extent of the solar facility. All related equipment including buildings, power substations, and other associated infrastructure were included within the solar facility. If solar infrastructure was indistinguishable from adjacent infrastructure, or if solar panels were installed on existing building tops, only the solar collecting equipment was digitized. The "Polygon" field indicates whether the "equipment footprint" or the full "site outline" was digitized. The spatial accuracy of features that represent site perimeters or an equipment footprint is estimated at +/- 10 meters. Facilities under construction or not fully visible in the NAIP imagery at the time of digitization (December 2011) are represented by an approximate site outline based on the best available information and documenting materials. The spatial accuracy of these facilities cannot be estimated without more up-to-date imagery – users are advised to consult more recent imagery as it becomes available. The "Status" field provides information about the operational status of each facility as of December 2011. This data series contributes to an Online Interactive Energy Atlas currently in development by the U.S. Geological Survey. The Energy Atlas will synthesize data on existing and potential energy development in Colorado and New Mexico and will include additional natural resource data layers. This information may be used by decision makers to evaluate and compare the potential benefits and tradeoffs associated with different energy development strategies or scenarios. Interactive maps, downloadable data layers, metadata, and decision support tools will be included in the Energy Atlas. The format of the Energy Atlas will facilitate the integration of information about energy with key terrestrial and aquatic resources for evaluating resource values and minimizing risks from energy development activities.

  14. 10 CFR Appendix F to Part 50 - Policy Relating to the Siting of Fuel Reprocessing Plants and Related Waste Management Facilities

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... and Related Waste Management Facilities F Appendix F to Part 50 Energy NUCLEAR REGULATORY COMMISSION... Relating to the Siting of Fuel Reprocessing Plants and Related Waste Management Facilities 1. Public health... facilities for the temporary storage of highlevel radioactive wastes, may be located on privately owned...

  15. 10 CFR Appendix F to Part 50 - Policy Relating to the Siting of Fuel Reprocessing Plants and Related Waste Management Facilities

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... and Related Waste Management Facilities F Appendix F to Part 50 Energy NUCLEAR REGULATORY COMMISSION... Relating to the Siting of Fuel Reprocessing Plants and Related Waste Management Facilities 1. Public health... facilities for the temporary storage of highlevel radioactive wastes, may be located on privately owned...

  16. 10 CFR Appendix F to Part 50 - Policy Relating to the Siting of Fuel Reprocessing Plants and Related Waste Management Facilities

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... and Related Waste Management Facilities F Appendix F to Part 50 Energy NUCLEAR REGULATORY COMMISSION... Relating to the Siting of Fuel Reprocessing Plants and Related Waste Management Facilities 1. Public health... facilities for the temporary storage of highlevel radioactive wastes, may be located on privately owned...

  17. Evaluating Past and Future USCG Use of Ohmsett Test Facility

    DTIC Science & Technology

    2016-10-01

    and Renewable Energy Test Facility, that was previously known as a fully capitalized acronym, Ohmsett. This facility is located on the U.S. Naval...Oil Spill Response Research and Renewable Energy Test Facility, that was previously known as a fully capitalized acronym, Ohmsett. This facility is...Incident Management Systems NSF National Strike Force NWS Naval Weapons Station Ohmsett National Oil Spill Response Research and Renewable Energy

  18. NACA Zero Power Reactor Facility Hazards Summary

    NASA Technical Reports Server (NTRS)

    1957-01-01

    The Lewis Flight Propulsion Laboratory of the National Advisory Committee for Aeronautics proposes to build a zero power research reactor facility which will be located in the laboratory grounds near Clevelaurd, Ohio. The purpose of this report is to inform the Advisory Commit tee on Reactor Safeguards of the U. S. Atomic Energy Commission in re gard to the design of the reactor facility, the cha,acteristics of th e site, and the hazards of operation at this location, The purpose o f this reactor is to perform critical experiments, to measure reactiv ity effects, to serve as a neutron source, and to serve as a training tool. The reactor facility is described. This is followed by a discu ssion of the nuclear characteristics and the control system. Site cha racteristics are then discussed followed by a discussion of the exper iments which may be conducted in the facility. The potential hazards of the facility are then considered, particularly, the maximum credib le accident. Finally, the administrative procedure is discussed.

  19. Location | Frederick National Laboratory for Cancer Research

    Cancer.gov

    The Frederick National Laboratory for Cancer Research campus is located 50 miles northwest of Washington, D.C., and 50 miles west of Baltimore, Maryland, in Frederick, Maryland. Satellite locations include leased and government facilities extending s

  20. Association of U.S. Dialysis Facility Neighborhood Characteristics with Facility-Level Kidney Transplantation

    PubMed Central

    Plantinga, Laura; Pastan, Stephen; Kramer, Michael; McClellan, Ann; Krisher, Jenna; Patzer, Rachel E.

    2014-01-01

    Background Improving access to optimal healthcare may depend on attributes of neighborhoods where patients receive healthcare services. We investigated whether characteristics of dialysis facility neighborhoods—where most patients with end-stage renal disease are treated—were associated with facility-level kidney transplantation. Methods We examined the association between census tract (neighborhood)-level sociodemographic factors and facility-level kidney transplantation rate in 3,983 U.S. dialysis facilities with reported kidney transplantation rates. Number of kidney transplants and total person-years contributed at the facility level in 2007-2010 were obtained from the Dialysis Facility Report and linked to census tract data on sociodemographic characteristics from the American Community Survey 2006-2010 by dialysis facility location. We used multivariable Poisson models with generalized estimating equations to estimate associations between neighborhood characteristics and transplant incidence. Results U.S. dialysis facilities were located in neighborhoods with substantially greater proportions of black and poor residents, relative to the national average. Most facility neighborhood characteristics were associated with transplant, with incidence rate ratios (95% CI) for standardized increments (in percentage) of neighborhood exposures of: living in poverty, 0.88 (0.84-0.92), black race, 0.83 (0.78-0.89); high school graduates, 1.22 (1.17-1.26); and unemployed, 0.90 (0.85-0.95). Conclusion Dialysis facility neighborhood characteristics may be modestly associated with facility rates of kidney transplantation. The success of dialysis facility interventions to improve access to kidney transplantation may partially depend on reducing neighborhood-level barriers. PMID:25196018

  1. Methods to measure potential spatial access to delivery care in low- and middle-income countries: a case study in rural Ghana.

    PubMed

    Nesbitt, Robin C; Gabrysch, Sabine; Laub, Alexandra; Soremekun, Seyi; Manu, Alexander; Kirkwood, Betty R; Amenga-Etego, Seeba; Wiru, Kenneth; Höfle, Bernhard; Grundy, Chris

    2014-06-26

    Access to skilled attendance at childbirth is crucial to reduce maternal and newborn mortality. Several different measures of geographic access are used concurrently in public health research, with the assumption that sophisticated methods are generally better. Most of the evidence for this assumption comes from methodological comparisons in high-income countries. We compare different measures of travel impedance in a case study in Ghana's Brong Ahafo region to determine if straight-line distance can be an adequate proxy for access to delivery care in certain low- and middle-income country (LMIC) settings. We created a geospatial database, mapping population location in both compounds and village centroids, service locations for all health facilities offering delivery care, land-cover and a detailed road network. Six different measures were used to calculate travel impedance to health facilities (straight-line distance, network distance, network travel time and raster travel time, the latter two both mechanized and non-mechanized). The measures were compared using Spearman rank correlation coefficients, absolute differences, and the percentage of the same facilities identified as closest. We used logistic regression with robust standard errors to model the association of the different measures with health facility use for delivery in 9,306 births. Non-mechanized measures were highly correlated with each other, and identified the same facilities as closest for approximately 80% of villages. Measures calculated from compounds identified the same closest facility as measures from village centroids for over 85% of births. For 90% of births, the aggregation error from using village centroids instead of compound locations was less than 35 minutes and less than 1.12 km. All non-mechanized measures showed an inverse association with facility use of similar magnitude, an approximately 67% reduction in odds of facility delivery per standard deviation increase in each measure (OR = 0.33). Different data models and population locations produced comparable results in our case study, thus demonstrating that straight-line distance can be reasonably used as a proxy for potential spatial access in certain LMIC settings. The cost of obtaining individually geocoded population location and sophisticated measures of travel impedance should be weighed against the gain in accuracy.

  2. Stochastic Multi-Commodity Facility Location Based on a New Scenario Generation Technique

    NASA Astrophysics Data System (ADS)

    Mahootchi, M.; Fattahi, M.; Khakbazan, E.

    2011-11-01

    This paper extends two models for stochastic multi-commodity facility location problem. The problem is formulated as two-stage stochastic programming. As a main point of this study, a new algorithm is applied to efficiently generate scenarios for uncertain correlated customers' demands. This algorithm uses Latin Hypercube Sampling (LHS) and a scenario reduction approach. The relation between customer satisfaction level and cost are considered in model I. The risk measure using Conditional Value-at-Risk (CVaR) is embedded into the optimization model II. Here, the structure of the network contains three facility layers including plants, distribution centers, and retailers. The first stage decisions are the number, locations, and the capacity of distribution centers. In the second stage, the decisions are the amount of productions, the volume of transportation between plants and customers.

  3. Pricing and location decisions in multi-objective facility location problem with M/M/m/k queuing systems

    NASA Astrophysics Data System (ADS)

    Tavakkoli-Moghaddam, Reza; Vazifeh-Noshafagh, Samira; Taleizadeh, Ata Allah; Hajipour, Vahid; Mahmoudi, Amin

    2017-01-01

    This article presents a new multi-objective model for a facility location problem with congestion and pricing policies. This model considers situations in which immobile service facilities are congested by a stochastic demand following M/M/m/k queues. The presented model belongs to the class of mixed-integer nonlinear programming models and NP-hard problems. To solve such a hard model, a new multi-objective optimization algorithm based on a vibration theory, namely multi-objective vibration damping optimization (MOVDO), is developed. In order to tune the algorithms parameters, the Taguchi approach using a response metric is implemented. The computational results are compared with those of the non-dominated ranking genetic algorithm and non-dominated sorting genetic algorithm. The outputs demonstrate the robustness of the proposed MOVDO in large-sized problems.

  4. Space Power Facility-Capabilities for Space Environmental Testing Within a Single Facility

    NASA Technical Reports Server (NTRS)

    Sorge, Richard N.

    2013-01-01

    The purpose of this paper is to describe the current and near-term environmental test capabilities of the NASA Glenn Research Center's Space Power Facility (SPF) located at Sandusky, Ohio. The paper will present current and near-term capabilities for conducting electromagnetic interference and compatibility testing, base-shake sinusoidal vibration testing, reverberant acoustic testing, and thermal-vacuum testing. The paper will also present modes of transportation, handling, ambient environments, and operations within the facility to conduct those tests. The SPF is in the midst of completing and activating new or refurbished capabilities which, when completed, will provide the ability to conduct most or all required full-scale end-assembly space simulation tests at a single test location. It is envisioned that the capabilities will allow a customer to perform a wide range of space simulation tests in one facility at reasonable cost.

  5. Radiological survey of the Mare Island Naval Shipyard, Alameda Naval Air Station, and Hunters Point Shipyard

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Semler, M.O.; Blanchard, R.L.

    1989-06-01

    Since 1963, the Eastern Environmental Radiation Facility (EERF), US Environmental Protection Agency (USEPA), in cooperation with the US Naval Sea Systems Command (NAVSEA) has surveyed facilities serving nuclear-powered warships on the Atlantic and Pacific coasts and the Gulf of Mexico. These surveys assess whether the operation of nuclear-powered warships, during construction, maintenance, overhaul, or refueling, have created elevated levels of radioactivity. The surveys emphasize sampling those areas and pathways that could expose the public. In 1984, NAVSEA requested that EPA survey all active facilities serving nuclear-powered warships over the next three years. This report contains the results of surveys conductedmore » at Naval facilities located at Mare Island, Alameda, and Hunters Point in the San Francisco region. The locations of these facilities are shown. 3 refs., 4 figs., 3 tabs.« less

  6. U.S. EPAs Geospatial Data Access Project

    EPA Pesticide Factsheets

    To improve public health and the environment, the United States Environmental Protection Agency (EPA) collects information about facilities, sites, or places subject to environmental regulation or of environmental interest. Through the Geospatial Data Download Service, the public is now able to download the EPA Geodata Shapefile, Feature Class or extensible markup language (XML) file containing facility and site information from EPA's national program systems. The files are Internet accessible from the Envirofacts Web site (https://www3.epa.gov/enviro/). The data may be used with geospatial mapping applications. (Note: The files omit facilities without latitude/longitude coordinates.) The EPA Geospatial Data contains the name, location (latitude/longitude), and EPA program information about specific facilities and sites. In addition, the files contain a Uniform Resource Locator (URL), which allows mapping applications to present an option to users to access additional EPA data resources on a specific facility or site.

  7. Rural-urban differences in end-of-life nursing home care: facility and environmental factors.

    PubMed

    Temkin-Greener, Helena; Zheng, Nan Tracy; Mukamel, Dana B

    2012-06-01

    This study examines urban-rural differences in end-of-life (EOL) quality of care provided to nursing home (NH) residents. We constructed 3 risk-adjusted EOL quality measures (QMs) for long-term decedent residents: in-hospital death, hospice referral before death, and presence of severe pain. We used CY2005-2007 100% Minimum Data Set, Medicare beneficiary file, and inpatient and hospice claims. Logistic regression models were estimated to predict the probability of each outcome conditional on decedents' risk factors. For each facility, QMs were calculated as the difference between the actual and the expected risk-adjusted outcome rates. We fit multivariate linear regression models, with fixed state effects, for each QM to assess the association with urban-rural location. We found urban-rural differences for in-hospital death and hospice QMs, but not for pain. Compared with NHs located in urban areas, facilities in smaller towns and in isolated rural areas have significantly (p < .001) worse EOL quality for in-hospital death and hospice use. Whereas the differences in these QMs are statistically significant between facilities located in large versus small towns, they are not statistically significant between facilities located in small towns and isolated rural areas. This study provides empirical evidence for urban-rural differences in EOL quality of care using a national sample of NHs. Identifying differences is a necessary first step toward improving care for dying NH residents and for bridging the urban-rural gap.

  8. 10 CFR 75.11 - Location information.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 2 2011-01-01 2011-01-01 false Location information. 75.11 Section 75.11 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) SAFEGUARDS ON NUCLEAR MATERIAL-IMPLEMENTATION OF US/IAEA AGREEMENT Facility and Location Information § 75.11 Location information. (a) As required by the Additional Protocol...

  9. KENNEDY SPACE CENTER, FLA. - Dr. Paul Hintze (left) explains to Center Director Jim Kennedy a project he is working at the KSC Beach Corrosion Test Site. Hitze is doing post-graduate work for the National Research Council. The test facility site was established in the 1960s and has provided more than 30 years of historical information on the long-term performance of many materials in use at KSC and other locations around the world. Located 100 feet from the Atlantic Ocean approximately 1 mile south of the Space Shuttle launch sites, the test facility includes an atmospheric exposure site, a flowing seawater exposure site, and an on-site electrochemistry laboratory and monitoring station. The beach laboratory is used to conduct real-time corrosion experiments and provides for the remote monitoring of surrounding weather conditions. The newly added flowing seawater immersion facility provides for the immersion testing of materials and devices under controlled conditions.

    NASA Image and Video Library

    2003-08-21

    KENNEDY SPACE CENTER, FLA. - Dr. Paul Hintze (left) explains to Center Director Jim Kennedy a project he is working at the KSC Beach Corrosion Test Site. Hitze is doing post-graduate work for the National Research Council. The test facility site was established in the 1960s and has provided more than 30 years of historical information on the long-term performance of many materials in use at KSC and other locations around the world. Located 100 feet from the Atlantic Ocean approximately 1 mile south of the Space Shuttle launch sites, the test facility includes an atmospheric exposure site, a flowing seawater exposure site, and an on-site electrochemistry laboratory and monitoring station. The beach laboratory is used to conduct real-time corrosion experiments and provides for the remote monitoring of surrounding weather conditions. The newly added flowing seawater immersion facility provides for the immersion testing of materials and devices under controlled conditions.

  10. 40 CFR 35.6120 - Notification of the out-of-State or out-of-an-Indian-Tribal-area-of-Indian-country transfer of...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... provide the following information, where available: (1) The name and location of the facility to which the CERCLA waste is to be shipped; (2) The type and quantity of CERCLA waste to be shipped; (3) The expected... facility is located of major changes in the shipment plan, such as a decision to ship the CERCLA waste to...

  11. 40 CFR 35.6120 - Notification of the out-of-State or out-of-an-Indian-Tribal-area-of-Indian-country transfer of...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... provide the following information, where available: (1) The name and location of the facility to which the CERCLA waste is to be shipped; (2) The type and quantity of CERCLA waste to be shipped; (3) The expected... facility is located of major changes in the shipment plan, such as a decision to ship the CERCLA waste to...

  12. 40 CFR 35.6120 - Notification of the out-of-State or out-of-an-Indian-Tribal-area-of-Indian-country transfer of...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... provide the following information, where available: (1) The name and location of the facility to which the CERCLA waste is to be shipped; (2) The type and quantity of CERCLA waste to be shipped; (3) The expected... facility is located of major changes in the shipment plan, such as a decision to ship the CERCLA waste to...

  13. The Waite Campus: Industry, Research and Educational Collaboration.

    ERIC Educational Resources Information Center

    PEB Exchange, 1997

    1997-01-01

    The Waite Campus at the University of Adelaide, South Australia, houses industrial, research, and educational organizations. One advantage of this co-location is sharing the cost of facilities and equipment. The facilities described include Plant Research Center, Wine Science Laboratory, refectory, library, conference facilities, teleteaching,…

  14. Hazardous Waste Cleanup: Von Roll Isola USA Incorporated in Schenectady, New York

    EPA Pesticide Factsheets

    The Riverview facility is a 52-acre manufacturing facility located on Von Roll Drive in Schenectady, New York. The facility is owned and operated by Von Roll Isola USA, Inc., and produces solid and liquid insulating materials and tapes for the electrical

  15. DOE passive solar commercial buildings program: project summaries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1982-01-01

    The 23 projects participating in this program comprise a wide range of building types including offices, retail establishments, educational facilities, public service facilities, community and visitor centers, and private specialized-use facilities, located throughout the United States. Summary data and drawings are presented for each project. (MHR)

  16. 30 CFR 77.1608 - Dumping facilities.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Dumping facilities. 77.1608 Section 77.1608 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH... Haulage § 77.1608 Dumping facilities. (a) Dumping locations and haulage roads shall be kept reasonably...

  17. 37 CFR 102.2 - Public reference facilities.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 37 Patents, Trademarks, and Copyrights 1 2011-07-01 2011-07-01 false Public reference facilities. 102.2 Section 102.2 Patents, Trademarks, and Copyrights UNITED STATES PATENT AND TRADEMARK OFFICE... thereto. The public reference facility is located in the Public Search Room, Madison Building East, First...

  18. 37 CFR 102.2 - Public reference facilities.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 37 Patents, Trademarks, and Copyrights 1 2014-07-01 2014-07-01 false Public reference facilities. 102.2 Section 102.2 Patents, Trademarks, and Copyrights UNITED STATES PATENT AND TRADEMARK OFFICE... thereto. The public reference facility is located in the Public Search Room, Madison Building East, First...

  19. 37 CFR 102.2 - Public reference facilities.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 37 Patents, Trademarks, and Copyrights 1 2013-07-01 2013-07-01 false Public reference facilities. 102.2 Section 102.2 Patents, Trademarks, and Copyrights UNITED STATES PATENT AND TRADEMARK OFFICE... thereto. The public reference facility is located in the Public Search Room, Madison Building East, First...

  20. 37 CFR 102.2 - Public reference facilities.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 37 Patents, Trademarks, and Copyrights 1 2012-07-01 2012-07-01 false Public reference facilities. 102.2 Section 102.2 Patents, Trademarks, and Copyrights UNITED STATES PATENT AND TRADEMARK OFFICE... thereto. The public reference facility is located in the Public Search Room, Madison Building East, First...

  1. 37 CFR 102.2 - Public reference facilities.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 37 Patents, Trademarks, and Copyrights 1 2010-07-01 2010-07-01 false Public reference facilities. 102.2 Section 102.2 Patents, Trademarks, and Copyrights UNITED STATES PATENT AND TRADEMARK OFFICE... thereto. The public reference facility is located in the Public Search Room, Madison Building East, First...

  2. 27 CFR 24.41 - Office facilities.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Office facilities. 24.41... § 24.41 Office facilities. The appropriate TTB officer may require the proprietor to furnish... performing Government duties whether or not such office space is located at the specific premises where...

  3. 21 CFR 110.37 - Sanitary facilities and controls.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... HUMAN FOOD Buildings and Facilities § 110.37 Sanitary facilities and controls. Each plant shall be... water to required locations throughout the plant. (2) Properly convey sewage and liquid disposable waste from the plant. (3) Avoid constituting a source of contamination to food, water supplies, equipment, or...

  4. 21 CFR 110.37 - Sanitary facilities and controls.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... HUMAN FOOD Buildings and Facilities § 110.37 Sanitary facilities and controls. Each plant shall be... water to required locations throughout the plant. (2) Properly convey sewage and liquid disposable waste from the plant. (3) Avoid constituting a source of contamination to food, water supplies, equipment, or...

  5. 21 CFR 110.37 - Sanitary facilities and controls.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... HUMAN FOOD Buildings and Facilities § 110.37 Sanitary facilities and controls. Each plant shall be... water to required locations throughout the plant. (2) Properly convey sewage and liquid disposable waste from the plant. (3) Avoid constituting a source of contamination to food, water supplies, equipment, or...

  6. 9 CFR 149.7 - Recordkeeping at site.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    .... If the carcass storage facility or composting facility is located on the site, then the animal disposal plan must provide for a storage or composting facility that precludes rodent or wildlife contact... swine and other mammals by rendering, incineration, composting, burial, or other means, as allowed by...

  7. A Sketch of the Taiwan Zebrafish Core Facility.

    PubMed

    You, May-Su; Jiang, Yun-Jin; Yuh, Chiou-Hwa; Wang, Chien-Ming; Tang, Chih-Hao; Chuang, Yung-Jen; Lin, Bo-Hung; Wu, Jen-Leih; Hwang, Sheng-Ping L

    2016-07-01

    In the past three decades, the number of zebrafish laboratories has significantly increased in Taiwan. The Taiwan Zebrafish Core Facility (TZCF), a government-funded core facility, was launched to serve this growing community. The Core Facility was built on two sites, one located at the National Health Research Institutes (NHRI, called Taiwan Zebrafish Core Facility at NHRI or TZeNH) and the other is located at the Academia Sinica (Taiwan Zebrafish Core Facility at AS a.k.a. TZCAS). The total surface area of the TZCF is about 180 m(2) encompassing 2880 fish tanks. Each site has a separate quarantine room and centralized water recirculating systems, monitoring key water parameters. To prevent diseases, three main strategies have been implemented: (1) imported fish must be quarantined; (2) only bleached embryos are introduced into the main facilities; and (3) working practices were implemented to minimize pathogen transfer between stocks and facilities. Currently, there is no health program in place; however, a fourth measure for the health program, specific regular pathogen tests, is being planned. In March 2015, the TZCF at NHRI has been AAALAC accredited. It is our goal to ensure that we provide "disease-free" fish and embryos to the Taiwanese research community.

  8. ART Attrition across Health Facilities Implementing Option B+ in Haiti.

    PubMed

    Myrtil, Martine Pamphile; Puttkammer, Nancy; Gloyd, Stephen; Robinson, Julia; Yuhas, Krista; Domercant, Jean Wysler; Honoré, Jean Guy; Francois, Kesner

    2018-01-01

    Describing factors related to high attrition is important in order to improve the implementation of the Option B+ strategy in Haiti. We conducted a retrospective cohort study to describe the variability of antiretroviral therapy (ART) retention across health facilities among pregnant and lactating women and assess for differences in ART retention between Option B+ clients and other ART patients. There were 1989 Option B+ clients who initiated ART in 45 health facilities. The percentage of attrition varied from 9% to 81% across the facilities. The largest health facilities had 38% higher risk of attrition (relative risk [RR]: 1.38, 95% confidence interval [CI]: 1.08-1.77, P = .009). Private institutions had 18% less risk of attrition (RR: 0.82, 95% CI: 0.70-0.96, P = .020). Health facilities located in the West department and the South region had lower risk of attrition. Being on treatment in a large or public health facility or a facility located in the North region was a significant risk factor associated with high attrition among Option B+ clients. The implementation of the Option B+ strategy must be reevaluated in order to effectively eliminate mother-to-child HIV transmission.

  9. Wi-Fi real time location systems

    NASA Astrophysics Data System (ADS)

    Doll, Benjamin A.

    This thesis objective was to determine the viability of utilizing an untrained Wi-Fi. real time location system as a GPS alternative for indoor environments. Background. research showed that GPS is rarely able to penetrate buildings to provide reliable. location data. The benefit of having location information in a facility and how they might. be used for disaster or emergency relief personnel and their resources motivated this. research. A building was selected with a well-deployed Wi-Fi infrastructure and its. untrained location feature was used to determine the distance between the specified. test points and the system identified location. It was found that the average distance. from the test point throughout the facility was 14.3 feet 80% of the time. This fell within. the defined viable range and supported that an untrained Wi-Fi RTLS system could be a. viable solution for GPS's lack of availability indoors.

  10. A Deep Underground Science and Engineering Laboratory (DUSEL) at Kimballton

    NASA Astrophysics Data System (ADS)

    Vogelaar, R. Bruce

    2004-11-01

    The National Academy of Science, as well as several long-range plans from the physics communities, have endorsed the need to create a large, multi-disciplinary underground laboratory in the US. Several potential sites have been identified, and the National Science Foundation has begun a solicitation process to help formulate the science program as well as to identify and develop candidate sites. The only site on the East Coast is at Kimballton, near Blacksburg, in western Virginia. Of all the sites, it is the only one located in sedimentary rocks. This makes it an IDEAL and unique location for both physics, geoscience, and engineering studies. Kimballton is also only half an hour from Virginia Tech, the largest university in the state of Virginia. A multi-institution group has been developing this possibility, and will be competing on the national scale to have DUSEL located at Kimballton. One of the assets of this location is a large limestone mine, already at a depth of 2300 ft (1850 mwe), with true drive-in access and extremely large caverns. The DUSEL facility at this location will try to take advantage of the existing infrastructure, while at the same time develop complementary and adjacent facilities down to 7000 ft (6000 mwe) to allow independent operation of the future facility. Since 2003, Virginia Tech and the Naval Research Laboratory have been working to also develop a general low-level facility at this location. The initial program is to help develop extremely low-background germanium and gas proportional counters, and a single super-module of the Low-Energy Neutrino Spectroscopy (LENS) detector -- designed to measure the real-time low-energy neutrino spectrum from the Sun, including the pp-flux. Progress in this program (including seismic imaging), and the proposed overall extensive science program (Phys, Geo, Eng, Bio) which can be addressed at Kimballton will be presented. For further information, see our webpage http://www.phys.vt.edu/ kimballton/ Clearly, if such a national facility were located in the south-east it would be a tremendous resource to regional universities and laboratories. New partners and collaborators are very welcome.

  11. Engine component instrumentation development facility at NASA Lewis Research Center

    NASA Technical Reports Server (NTRS)

    Bruckner, Robert J.; Buggele, Alvin E.; Lepicovsky, Jan

    1992-01-01

    The Engine Components Instrumentation Development Facility at NASA Lewis is a unique aeronautics facility dedicated to the development of innovative instrumentation for turbine engine component testing. Containing two separate wind tunnels, the facility is capable of simulating many flow conditions found in most turbine engine components. This facility's broad range of capabilities as well as its versatility provide an excellent location for the development of novel testing techniques. These capabilities thus allow a more efficient use of larger and more complex engine component test facilities.

  12. Integer Optimization Model for a Logistic System based on Location-Routing Considering Distance and Chosen Route

    NASA Astrophysics Data System (ADS)

    Mulyasari, Joni; Mawengkang, Herman; Efendi, Syahril

    2018-02-01

    In a distribution network it is important to decide the locations of facilities that impacts not only the profitability of an organization but the ability to serve customers.Generally the location-routing problem is to minimize the overall cost by simultaneously selecting a subset of candidate facilities and constructing a set of delivery routes that satisfy some restrictions. In this paper we impose restriction on the route that should be passed for delivery. We use integer programming model to describe the problem. A feasible neighbourhood search is proposed to solve the result model.

  13. 30 CFR 250.241 - What must the DPP or DOCD include?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... and production activities include: (1) Development drilling; (2) Well test flaring; (3) Installation... production operations. (b) Location. The location and water depth of each of your proposed wells and... proposed well, the surface location of each production facility, and the locations of all associated...

  14. Not in whose backyard? Minority population concentrations and noxious facility sites

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nieves, L.A.

    1992-04-01

    The NIMBY (not in may backyard) syndrome has become the nemesis of facility siting efforts in the USA. Given people`s reluctance to live near noxious facilities, in whose backyard are such facilities located? This study employs US county-level data to examine relative concentrations of minorities living near noxious facilities. Facility types analyzed include electric generating plants, manufacturing plants, Superfund sites, and radioactive waste disposal sites. While this study does not address which cam first, the minority population concentration or the noxious facilities, it documents their current degree of association.

  15. Not in whose backyard Minority population concentrations and noxious facility sites

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nieves, L.A.

    1992-01-01

    The NIMBY (not in may backyard) syndrome has become the nemesis of facility siting efforts in the USA. Given people's reluctance to live near noxious facilities, in whose backyard are such facilities located This study employs US county-level data to examine relative concentrations of minorities living near noxious facilities. Facility types analyzed include electric generating plants, manufacturing plants, Superfund sites, and radioactive waste disposal sites. While this study does not address which cam first, the minority population concentration or the noxious facilities, it documents their current degree of association.

  16. Survey of aircraft icing simulation test facilities in North America

    NASA Technical Reports Server (NTRS)

    Olsen, W.

    1981-01-01

    A survey was made of the aircraft icing simulation facilities in North America: there are 12 wind tunnels, 28 engine test facilities, 6 aircraft tankers and 14 low velocity facilities, that perform aircraft icing tests full or part time. The location and size of the facility, its speed and temperature range, icing cloud parameters, and the technical person to contact are surveyed. Results are presented in tabular form. The capabilities of each facility were estimated by its technical contact person. The adequacy of these facilities for various types of icing tests is discussed.

  17. 44 CFR 201.4 - Standard State Mitigation Plans.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... State owned or operated buildings, infrastructure, and critical facilities located in the identified... vulnerable to damage and loss associated with hazard events. State owned or operated critical facilities...

  18. 44 CFR 201.4 - Standard State Mitigation Plans.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... State owned or operated buildings, infrastructure, and critical facilities located in the identified... vulnerable to damage and loss associated with hazard events. State owned or operated critical facilities...

  19. Planning the location of facilities to implement a reverse logistic system of post-consumer packaging using a location mathematical model.

    PubMed

    Couto, Maria Claudia Lima; Lange, Liséte Celina; Rosa, Rodrigo de Alvarenga; Couto, Paula Rogeria Lima

    2017-12-01

    The implementation of reverse logistics systems (RLS) for post-consumer products provides environmental and economic benefits, since it increases recycling potential. However, RLS implantation and consolidation still face problems. The main shortcomings are the high costs and the low expectation of broad implementation worldwide. This paper presents two mathematical models to decide the number and the location of screening centers (SCs) and valorization centers (VCs) to implement reverse logistics of post-consumer packages, defining the optimum territorial arrangements (OTAs), allowing the inclusion of small and medium size municipalities. The paper aims to fill a gap in the literature on RLS location facilities that not only aim at revenue optimization, but also the participation of the population, the involvement of pickers and the service universalization. The results showed that implementation of VCs can lead to revenue/cost ratio higher than 100%. The results of this study can supply companies and government agencies with a global view on the parameters that influence RLS sustainability and help them make decisions about the location of these facilities and the best reverse flows with the social inclusion of pickers and serving the population of small and medium-sized municipalities.

  20. Joint Optimization of Distribution Network Design and Two-Echelon Inventory Control with Stochastic Demand and CO2 Emission Tax Charges.

    PubMed

    Li, Shuangyan; Li, Xialian; Zhang, Dezhi; Zhou, Lingyun

    2017-01-01

    This study develops an optimization model to integrate facility location and inventory control for a three-level distribution network consisting of a supplier, multiple distribution centers (DCs), and multiple retailers. The integrated model addressed in this study simultaneously determines three types of decisions: (1) facility location (optimal number, location, and size of DCs); (2) allocation (assignment of suppliers to located DCs and retailers to located DCs, and corresponding optimal transport mode choices); and (3) inventory control decisions on order quantities, reorder points, and amount of safety stock at each retailer and opened DC. A mixed-integer programming model is presented, which considers the carbon emission taxes, multiple transport modes, stochastic demand, and replenishment lead time. The goal is to minimize the total cost, which covers the fixed costs of logistics facilities, inventory, transportation, and CO2 emission tax charges. The aforementioned optimal model was solved using commercial software LINGO 11. A numerical example is provided to illustrate the applications of the proposed model. The findings show that carbon emission taxes can significantly affect the supply chain structure, inventory level, and carbon emission reduction levels. The delay rate directly affects the replenishment decision of a retailer.

  1. Public acceptance for centralized storage and repositories of low-level waste session (Panel)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lutz, H.R.

    1995-12-31

    Participants from various parts of the world will provide a summary of their particular country`s approach to low-level waste management and the cost of public acceptance for low-level waste management facilities. Participants will discuss the number, geographic location, and type of low-level waste repositories and centralized storage facilities located in their countries. Each will discuss the amount, distribution, and duration of funds to gain public acceptance of these facilities. Participants will provide an estimated $/meter for centralized storage facilities and repositories. The panel will include a brief discussion about the ethical aspects of public acceptance costs, approaches for negotiating acceptance,more » and lessons learned in each country. The audience is invited to participate in the discussion.« less

  2. Developing a plan for primary health care facilities in Soweto, South Africa. Part II: Applying locational criteria.

    PubMed

    Doherty, J; Rispel, L; Webb, N

    1996-12-01

    This article is the second of a two-part series describing the development of a ten-year plan for primary health care facility development in Soweto. The first article concentrated on the political problems and general methodological approach of the project. This second article describes how the technical problem of planning in the context of scanty information was overcome. The reasoning behind the various assumptions and criteria which were used to assist the planning of the location of facilities is explained, as well as the process by which they were applied. The merits and limitations of this planning approach are discussed, and it is suggested that the approach may be useful to other facility planners, particularly in the developing world.

  3. Scope of Work for Integration Management and Installation Services of the National Ignition Facility Beampath Infrastructure System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Coyle, P.D.

    2000-04-25

    The goal of the National Ignition Facility (NIF) project is to provide an aboveground experimental capability for maintaining nuclear competence and weapons effects simulation and to provide a facility capable of achieving fusion ignition using solid-state lasers as the energy driver. The facility will incorporate 192 laser beams, which will be focused onto a small target located at the center of a spherical target chamber--the energy from the laser beams will be deposited in a few billionths of a second. The target will then implode, forcing atomic nuclei to sufficiently high temperatures and densities necessary to achieve a miniature fusionmore » reaction. The NIF is under construction, at Livermore, California, located approximately 50 miles southeast of San Francisco, California.« less

  4. Scope of Work for Integration Management and Installation Services of the National Ignition Facility Beampath Infrastructure System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Coyle, P.D.

    The goal of the National Ignition Facility (NIF) project is to provide an aboveground experimental capability for maintaining nuclear competence and weapons effects simulation and to provide a facility capable of achieving fusion ignition using solid-state lasers as the energy driver. The facility will incorporate 192 laser beams, which will be focused onto a small target located at the center of a spherical target chamber--the energy from the laser beams will be deposited in a few billionths of a second. The target will then implode, forcing atomic nuclei to sufficiently high temperatures and densities necessary to achieve a miniature fusionmore » reaction. The NIF is under construction, at Livermore, California, located approximately 50 miles southeast of San Francisco, California.« less

  5. Israel: Possible Military Strike Against Iran’s Nuclear Facilities

    DTIC Science & Technology

    2012-03-27

    centrifuge facility and a larger commercial facility located at this site. The commercial facility is reportedly hardened by steel-reinforced concrete , buried...prime minister has had to contemplate. A strike against Iran’s nuclear facilities could lead to regional conflagration , tens of thousands of...high explosives, and can penetrate more than 6 feet of reinforced concrete . The GBU-28 5000-lb class weapon penetrates at least 20 feet of concrete

  6. The Otis Weather Test Facility at Otis ANGB, Falmouth, MA : an aviation weather resource

    DOT National Transportation Integrated Search

    2004-10-06

    The Otis Weather Test Facility (WTF) is located on the US Air National Guard Base, Cape Cod, MA. The Facility was originally established by the US Air Force Cambridge Research Laboratory [now Air Force Research Laboratory (AFRL)] in 1974 to develop a...

  7. 44 CFR 206.252 - Insurance requirements for facilities damaged by flood.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... facilities damaged by flood. 206.252 Section 206.252 Emergency Management and Assistance FEDERAL EMERGENCY... Assistance Insurance Requirements § 206.252 Insurance requirements for facilities damaged by flood. (a) Where an insurable building damaged by flooding is located in a special flood hazard area identified for...

  8. 18 CFR 292.203 - General requirements for qualification.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... certification, pursuant to § 292.207(b)(1), that has been granted. (c) Hydroelectric small power production facilities located at a new dam or diversion. (1) A hydroelectric small power production facility that..., pursuant to § 292.207(b)(1), that has been granted. (c) Hydroelectric small power production facilities...

  9. 28 CFR 91.55 - Categorical exclusions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... within or potentially affect any of the following: a 100-year flood plain, a wetland, important farmland... expand facilities that: (1) Are located in a floodplain; (2) Will affect a wetland; (3) Will affect a... correctional agency has contracted with the private vendor to build the facility, operate the facility, or...

  10. Work with Us | Photovoltaic Research | NREL

    Science.gov Websites

    Research Facility (SERF) Science and Technology Facility (S&TF) Outdoor Test Facility (OTF) Energy the Hands On Photovoltaic Experience (HOPE). Photo of a researcher in a lab Photovoltaic research and related activities occur in various locations across the NREL campus, including the Solar Energy Research

  11. Energy Systems Integration Facility Overview

    ScienceCinema

    Arvizu, Dan; Chistensen, Dana; Hannegan, Bryan; Garret, Bobi; Kroposki, Ben; Symko-Davies, Martha; Post, David; Hammond, Steve; Kutscher, Chuck; Wipke, Keith

    2018-01-16

    The U.S. Department of Energy's Energy Systems Integration Facility (ESIF) is located at the National Renewable Energy Laboratory is the right tool, at the right time... a first-of-its-kind facility that addresses the challenges of large-scale integration of clean energy technologies into the energy systems that power the nation.

  12. 7 CFR 301.75-4 - Quarantined areas.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... landfill or for composting in a recycling facility, if all of the following conditions are met: (A) The public landfill or recycling facility is located within the survey area described in paragraph (d)(1) of... the quarantined area to the public landfill or recycling facility, and (C) Any public landfill used is...

  13. 7 CFR 301.75-4 - Quarantined areas.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... landfill or for composting in a recycling facility, if all of the following conditions are met: (A) The public landfill or recycling facility is located within the survey area described in paragraph (d)(1) of... the quarantined area to the public landfill or recycling facility, and (C) Any public landfill used is...

  14. 7 CFR 301.75-4 - Quarantined areas.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... landfill or for composting in a recycling facility, if all of the following conditions are met: (A) The public landfill or recycling facility is located within the survey area described in paragraph (d)(1) of... the quarantined area to the public landfill or recycling facility, and (C) Any public landfill used is...

  15. 7 CFR 301.75-4 - Quarantined areas.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... landfill or for composting in a recycling facility, if all of the following conditions are met: (A) The public landfill or recycling facility is located within the survey area described in paragraph (d)(1) of... the quarantined area to the public landfill or recycling facility, and (C) Any public landfill used is...

  16. 40 CFR 60.620 - Applicability and designation of affected facility.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Performance for Petroleum Dry Cleaners § 60.620 Applicability and designation of affected facility. (a) The provisions of this subpart are applicable to the following affected facilities located at a petroleum dry... pounds): Petroleum solvent dry cleaning dryers, washers, filters, stills, and settling tanks. (1) When...

  17. Redirecting Under-Utilised Computer Laboratories into Cluster Computing Facilities

    ERIC Educational Resources Information Center

    Atkinson, John S.; Spenneman, Dirk H. R.; Cornforth, David

    2005-01-01

    Purpose: To provide administrators at an Australian university with data on the feasibility of redirecting under-utilised computer laboratories facilities into a distributed high performance computing facility. Design/methodology/approach: The individual log-in records for each computer located in the computer laboratories at the university were…

  18. A GUIDE FOR PLANNING PHYSICAL EDUCATION AND ATHLETIC FACILITIES.

    ERIC Educational Resources Information Center

    New Jersey State Dept. of Education, Trenton.

    THIS STUDY EXAMINES PHYSICAL EDUCATION FACILITIES, THEIR PHYSICAL NEEDS, AND RELATED DESIGN CONSIDERATIONS. A SYSTEM OF DETERMINING THE TOTAL NUMBER OF TEACHING STATIONS NEEDED IS GIVEN TO AID INITIAL REQUIREMENT ANALYSIS. INDOOR FACILITIES ANALYZED INCLUDE--(1) THE GYMNASIUM, IN TERMS OF LOCATION, SIZE, DESIGN FEATURES, AND RELATED COMPONENTS,…

  19. Concentrating Solar Power Projects - National Solar Thermal Power Facility

    Science.gov Websites

    | Concentrating Solar Power | NREL National Solar Thermal Power Facility Status Date: February 13, 2014 Project Overview Project Name: National Solar Thermal Power Facility Country: India Location Capacity (Net): 1.0 MW Output Type: Steam Rankine Thermal Storage Storage Type: None

  20. 34 CFR 395.16 - Permit for the establishment of vending facilities.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., the number, location and type of vending machines and other terms and conditions desired to be... 34 Education 2 2010-07-01 2010-07-01 false Permit for the establishment of vending facilities. 395...) OFFICE OF SPECIAL EDUCATION AND REHABILITATIVE SERVICES, DEPARTMENT OF EDUCATION VENDING FACILITY PROGRAM...

  1. EERE: Alternative Fuels Data Center Home Page

    Science.gov Websites

    facility safe with a first-of-its-kind CNG Maintenance Facility Modifications Handbook. Find Fleet & Equipment Maintenance Driving Behavior Fleet Rightsizing System Efficiency Locate Stations Search

  2. 7 CFR 1924.106 - Location.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... SERVICE, RURAL UTILITIES SERVICE, AND FARM SERVICE AGENCY, DEPARTMENT OF AGRICULTURE PROGRAM REGULATIONS..., either by location or terrain, to essential community facilities such as water, sewerage, schools...

  3. 7 CFR 1924.106 - Location.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... SERVICE, RURAL UTILITIES SERVICE, AND FARM SERVICE AGENCY, DEPARTMENT OF AGRICULTURE PROGRAM REGULATIONS..., either by location or terrain, to essential community facilities such as water, sewerage, schools...

  4. 7 CFR 1924.106 - Location.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... SERVICE, RURAL UTILITIES SERVICE, AND FARM SERVICE AGENCY, DEPARTMENT OF AGRICULTURE PROGRAM REGULATIONS..., either by location or terrain, to essential community facilities such as water, sewerage, schools...

  5. 7 CFR 1924.106 - Location.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... SERVICE, RURAL UTILITIES SERVICE, AND FARM SERVICE AGENCY, DEPARTMENT OF AGRICULTURE PROGRAM REGULATIONS..., either by location or terrain, to essential community facilities such as water, sewerage, schools...

  6. GIS analysis of the siting criteria for the Mixed and Low-Level Waste Treatment Facility and the Idaho Waste Processing Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoskinson, R.L.

    1994-01-01

    This report summarizes a study conducted using the Arc/Info{reg_sign} geographic information system (GIS) to analyze the criteria used for site selection for the Mixed and Low-Level Waste Treatment Facility (MLLWTF) and the Idaho Waste Processing Facility (IWPF). The purpose of the analyses was to determine, based on predefined criteria, the areas on the INEL that best satisfied the criteria. The coverages used in this study were produced by importing the AutoCAD files that produced the maps for a pre site selection draft report into the GIS. The files were then converted to Arc/Info{reg_sign} GIS format. The initial analysis was mademore » by considering all of the criteria as having equal importance in determining the areas of the INEL that would best satisfy the requirements. Another analysis emphasized four of the criteria as ``must`` criteria which had to be satisfied. Additional analyses considered other criteria that were considered for, but not included in the predefined criteria. This GIS analysis of the siting criteria for the IWPF and MLLWTF provides a logical, repeatable, and defensible approach to the determination of candidate locations for the facilities. The results of the analyses support the location of the Candidate Locations.« less

  7. Demonstration of Antimicrobial Corrosion-Resisting Interior Coating Systems for Military Facilities in Warm, Humid Locations

    DTIC Science & Technology

    2017-06-01

    ER D C/ CE RL T R- 17 -1 9 DoD Corrosion Prevention and Control Program Demonstration of Antimicrobial Corrosion- Resisting Interior ...Demonstration of Antimicrobial Corrosion- Resisting Interior Coating Systems for Military Facilities in Warm, Humid Locations Final Report on...Under Project F10-AR04, “Application of New Corrosion-Resistant Mold Abatement Technologies for Interior Surfaces of Buildings at Fort Polk, LA” ERDC

  8. 43 CFR 3271.14 - What do I need to do to start building and testing a utilization facility if it is not located on...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 43 Public Lands: Interior 2 2014-10-01 2014-10-01 false What do I need to do to start building and testing a utilization facility if it is not located on Federal lands leased for geothermal resources? 3271.14 Section 3271.14 Public Lands: Interior Regulations Relating to Public Lands (Continued) BUREAU OF LAND MANAGEMENT, DEPARTMENT OF THE...

  9. 43 CFR 3271.14 - What do I need to do to start building and testing a utilization facility if it is not located on...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 43 Public Lands: Interior 2 2012-10-01 2012-10-01 false What do I need to do to start building and testing a utilization facility if it is not located on Federal lands leased for geothermal resources? 3271.14 Section 3271.14 Public Lands: Interior Regulations Relating to Public Lands (Continued) BUREAU OF LAND MANAGEMENT, DEPARTMENT OF THE...

  10. 43 CFR 3271.14 - What do I need to do to start building and testing a utilization facility if it is not located on...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 43 Public Lands: Interior 2 2011-10-01 2011-10-01 false What do I need to do to start building and testing a utilization facility if it is not located on Federal lands leased for geothermal resources? 3271.14 Section 3271.14 Public Lands: Interior Regulations Relating to Public Lands (Continued) BUREAU OF LAND MANAGEMENT, DEPARTMENT OF THE...

  11. 43 CFR 3271.14 - What do I need to do to start building and testing a utilization facility if it is not located on...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 43 Public Lands: Interior 2 2013-10-01 2013-10-01 false What do I need to do to start building and testing a utilization facility if it is not located on Federal lands leased for geothermal resources? 3271.14 Section 3271.14 Public Lands: Interior Regulations Relating to Public Lands (Continued) BUREAU OF LAND MANAGEMENT, DEPARTMENT OF THE...

  12. 32 CFR 536.146 - Claims against nonappropriated fund employees-generally.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) activities. NAF activities include NAF or Army and Air Force Exchange Service (AAFES) facilities, post exchanges, bowling centers, officers and noncommissioned officers' clubs, and other facilities located on...

  13. 32 CFR 536.146 - Claims against nonappropriated fund employees-generally.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) activities. NAF activities include NAF or Army and Air Force Exchange Service (AAFES) facilities, post exchanges, bowling centers, officers and noncommissioned officers' clubs, and other facilities located on...

  14. 32 CFR 536.146 - Claims against nonappropriated fund employees-generally.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) activities. NAF activities include NAF or Army and Air Force Exchange Service (AAFES) facilities, post exchanges, bowling centers, officers and noncommissioned officers' clubs, and other facilities located on...

  15. 32 CFR 536.146 - Claims against nonappropriated fund employees-generally.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) activities. NAF activities include NAF or Army and Air Force Exchange Service (AAFES) facilities, post exchanges, bowling centers, officers and noncommissioned officers' clubs, and other facilities located on...

  16. 32 CFR 536.146 - Claims against nonappropriated fund employees-generally.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) activities. NAF activities include NAF or Army and Air Force Exchange Service (AAFES) facilities, post exchanges, bowling centers, officers and noncommissioned officers' clubs, and other facilities located on...

  17. KENNEDY SPACE CENTER, FLA. - Louis MacDowell (right), Testbed manager, explains to Center Director Jim Kennedy the use of astmospheric calibration specimens. Placed at various locations, they can rank the corrosivity of the given environment. The KSC Beach Corrosion Test Site was established in the 1960s and has provided more than 30 years of historical information on the long-term performance of many materials in use at KSC and other locations around the world. Located 100 feet from the Atlantic Ocean approximately 1 mile south of the Space Shuttle launch sites, the test facility includes an atmospheric exposure site, a flowing seawater exposure site, and an on-site electrochemistry laboratory and monitoring station. The beach laboratory is used to conduct real-time corrosion experiments and provides for the remote monitoring of surrounding weather conditions. The newly added flowing seawater immersion facility provides for the immersion testing of materials and devices under controlled conditions.

    NASA Image and Video Library

    2003-08-21

    KENNEDY SPACE CENTER, FLA. - Louis MacDowell (right), Testbed manager, explains to Center Director Jim Kennedy the use of astmospheric calibration specimens. Placed at various locations, they can rank the corrosivity of the given environment. The KSC Beach Corrosion Test Site was established in the 1960s and has provided more than 30 years of historical information on the long-term performance of many materials in use at KSC and other locations around the world. Located 100 feet from the Atlantic Ocean approximately 1 mile south of the Space Shuttle launch sites, the test facility includes an atmospheric exposure site, a flowing seawater exposure site, and an on-site electrochemistry laboratory and monitoring station. The beach laboratory is used to conduct real-time corrosion experiments and provides for the remote monitoring of surrounding weather conditions. The newly added flowing seawater immersion facility provides for the immersion testing of materials and devices under controlled conditions.

  18. 30 CFR 254.3 - May I cover more than one facility in my response plan?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false May I cover more than one facility in my... INTERIOR OFFSHORE OIL-SPILL RESPONSE REQUIREMENTS FOR FACILITIES LOCATED SEAWARD OF THE COAST LINE General § 254.3 May I cover more than one facility in my response plan? (a) Your response plan may be for a...

  19. 78 FR 44972 - Notice of Lodging of Proposed Consent Decree Under the Clean Air Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-25

    ... (``Title V'') and the regulations promulgated thereunder at 40 CFR part 71, at a facility known as PLA-9 Central Deliver Point, also known as PLA-9 CDP (the ``PLA-9 Facility''). The PLA-9 Facility is located... Indian Reservation. The PLA-9 Facility is now shut down. The Decree requires Williams pay a $63,000 civil...

  20. Physical, Structural and Operational Vulnerability of Critical Facilities in Valle de Chalco Solidaridad, Estado de Mexico, Mexico. Case of study: Avándaro, San Isidro and El Triunfo

    NASA Astrophysics Data System (ADS)

    Garcia Payne, D. G.; Novelo-Casanova, D. A.; Ponce-Pacheco, A. B.; Espinosa-Campos, O.; Huerta-Parra, M.; Reyes-Pimentel, T.; Rodriguez, F.; Benitez-Olivares, I.

    2010-12-01

    Valle de Chalco Solidaridad is located in Mexico City Metropolitan Area in Estado de Mexico, Mexico. In this town there is a sewage canal called “La Compañía”. A wall of this canal collapsed on February 5, 2010 due to heavy rains creating the flooding of four surrounding communities. It is important to point out that this area is frequently exposed to floods. In this work, we consider a critical facility as an essential structure for performance, health care and welfare within a community or/and as a place that can be used as shelter in case of emergency or disaster. Global vulnerability (the sum of the three measured vulnerabilities) of the 25 critical facilities identified in the locations of Avándaro, San Isidro and El Triunfo was assessed using the Community Vulnerability Assessment Tool developed by the National Oceanic and Atmospheric Administration (NOAA). For each critical facility we determined its operational, structural and physical vulnerabilities. For our analysis, we considered the four main natural hazards to which Valle de Chalco is exposed: earthquakes, floods, landslides and sinking. We considered five levels of vulnerability using a scale from 1 to 5, where values range from very low to very high vulnerability, respectively. A critical facilities database was generated by collecting general information for three categories: schools, government and church. Each facility was evaluated considering its location in relation to identified high-risk areas. Our results indicate that in average, the global vulnerability of all facilities is low, however, there are particular cases in which this global vulnerability is high. The average operational vulnerability of the three communities is moderate. The global structural vulnerability (sum of the structural vulnerability for the four analyzed hazards) is moderate. In particular, the structural vulnerability to earthquakes is low, to landslides is very low, to flooding is moderate and to sinking is low. Due to the location of the critical facilities, its global physical vulnerability (sum of the physical vulnerability to the four analyzed hazards) is moderate. Only three facilities have very high physical vulnerability to floods. Churches (six facilities) have the highest operational vulnerability, whereas its structural vulnerability is the lowest. Schools (13 facilities) have the lowest operational vulnerability, nevertheless, there are two schools with very high vulnerability. Regarding the six government facilities, we identified that their structural vulnerability range from moderate to high. As a result of this work, we believe in the importance of strengthening the culture of civil protection within the critical facilities of the communities of Valle de Chalco.

  1. The effect of environmental factors on technical and scale efficiency of primary health care providers in Greece.

    PubMed

    Kontodimopoulos, Nick; Moschovakis, Giorgos; Aletras, Vassilis H; Niakas, Dimitris

    2007-11-17

    The purpose of this study was to compare technical and scale efficiency of primary care centers from the two largest Greek providers, the National Health System (NHS) and the Social Security Foundation (IKA) and to determine if, and how, efficiency is affected by various exogenous factors such as catchment population and location. The sample comprised of 194 units (103 NHS and 91 IKA). Efficiency was measured with Data Envelopment Analysis (DEA) using three inputs, -medical staff, nursing/paramedical staff, administrative/other staff- and two outputs, which were the aggregated numbers of scheduled/emergency patient visits and imaging/laboratory diagnostic tests. Facilities were categorized as small, medium and large (<15,000, 15,000-30,000 and >30,000 respectively) to reflect catchment population and as urban/semi-urban or remote/island to reflect location. In a second stage analysis, technical and scale efficiency scores were regressed against facility type (NHS or IKA), size and location using multivariate Tobit regression. Regarding technical efficiency, IKA performed better than the NHS (84.9% vs. 70.1%, Mann-Whitney P < 0.001), smaller units better than medium-sized and larger ones (84.2% vs. 72.4% vs. 74.3%, Kruskal-Wallis P < 0.01) and remote/island units better than urban centers (81.1% vs. 75.7%, Mann-Whitney P = 0.103). As for scale efficiency, IKA again outperformed the NHS (89.7% vs. 85.9%, Mann-Whitney P = 0.080), but results were reversed in respect to facility size and location. Specifically, larger units performed better (96.3% vs. 90.9% vs. 75.9%, Kruskal-Wallis P < 0.001), and urban units showed higher scale efficiency than remote ones (91.9% vs. 75.3%, Mann-Whitney P < 0.001). Interestingly 75% of facilities appeared to be functioning under increasing returns to scale. Within-group comparisons revealed significant efficiency differences between the two primary care providers. Tobit regression models showed that facility type, size and location were significant explanatory variables of technical and scale efficiency. Variations appeared to exist in the productive performance of the NHS and IKA as the two main primary care providers in Greece. These variations reflect differences in primary care organization, economical incentives, financial constraints, sociodemographic and local peculiarities. In all technical efficiency comparisons, IKA facilities appeared to outperform NHS ones irrespective of facility size or location. In respect to scale efficiency, the results were to some extent inconclusive and observed differences were mostly insignificant, although again IKA appeared to perform better.

  2. Next Generation Gamma-Ray Cherenkov Detectors for the National Ignition Facility

    DOE PAGES

    Herrmann, Hans W.; Kim, Yong Ho; McEvoy, Aaron Matthew; ...

    2016-10-19

    The newest generation of Gas Cherenkov Detector (GCD-3) employed in Inertial Confinement Fusion experiments at the Omega Laser Facility has provided improved performance over previous generations. Comparison of reaction histories measured using two different deuterium-tritium fusion products, namely gamma rays using GCD and neutrons using Neutron Temporal Diagnostic (NTD), have provided added credibility to both techniques. GCD-3 is now being brought to the National Ignition Facility (NIF) to supplement the existing Gamma Reaction History (GRH-6m) located 6 m from target chamber center (TCC). Initially it will be located in a reentrant well located 3.9 m from TCC. Data from GCD-3more » will inform the design of a heavily-shielded “Super” GCD to be located as close as 20 cm from TCC. In conclusion, it will also provide a test-bed for faster optical detectors, potentially lowering the temporal resolution from the current ~100 ps state-of-the-art photomultiplier tubes (PMT) to ~10 ps Pulse Dilation PMT technology currently under development.« less

  3. Assisted Care Options (Brain Tumors)

    MedlinePlus

    ... Home Care & Hospice National Agency Locator Assisted Living Facilities and Nursing Homes For brain tumor patients who ... activities of daily living (ADLs), an assisted living facility can be a viable option. Your family member ...

  4. Real estate planning for population health.

    PubMed

    McHugh, Margie

    2014-11-01

    Factors that health systems should consider when performing strategic assessments of their portfolios of ambulatory facilities include: Inventory. Location Facility condition. Service mix. Space use and capacity. Occupancy metrics. Strategic and economic opportunities.

  5. 29 CFR 1918.97 - First aid and lifesaving facilities. (See appendix V of this part).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... in permanent locations shall be mounted to prevent damage and be protected from the elements if located out-of-doors. If concealed from view, enclosures shall be marked to indicate the location of the...

  6. Defining and describing birth centres in the Netherlands - a component study of the Dutch Birth Centre Study.

    PubMed

    Hermus, M A A; Boesveld, I C; Hitzert, M; Franx, A; de Graaf, J P; Steegers, E A P; Wiegers, T A; van der Pal-de Bruin, K M

    2017-07-03

    During the last decade, a rapid increase of birth locations for low-risk births, other than conventional obstetric units, has been seen in the Netherlands. Internationally some of such locations are called birth centres. The varying international definitions for birth centres are not directly applicable for use within the Dutch obstetric system. A standard definition for a birth centre in the Netherlands is lacking. This study aimed to develop a definition of birth centres for use in the Netherlands, to identify these centres and to describe their characteristics. International definitions of birth centres were analysed to find common descriptions. In July 2013 the Dutch Birth Centre Questionnaire was sent to 46 selected Dutch birth locations that might qualify as birth centre. Questions included: location, reason for establishment, women served, philosophies, facilities that support physiological birth, hotel-facilities, management, environment and transfer procedures in case of referral. Birth centres were visited to confirm the findings from the Dutch Birth Centre Questionnaire and to measure distance and time in case of referral to obstetric care. From all 46 birth locations the questionnaires were received. Based on this information a Dutch definition of a birth centre was constructed. This definition reads: "Birth centres are midwifery-managed locations that offer care to low risk women during labour and birth. They have a homelike environment and provide facilities to support physiological birth. Community midwives take primary professional responsibility for care. In case of referral the obstetric caregiver takes over the professional responsibility of care." Of the 46 selected birth locations 23 fulfilled this definition. Three types of birth centres were distinguished based on their location in relation to the nearest obstetric unit: freestanding (n = 3), alongside (n = 14) and on-site (n = 6). Transfer in case of referral was necessary for all freestanding and alongside birth centres. Birth centres varied in their reason for establishment and their characteristics. Twenty-three Dutch birth centres were identified and divided into three different types based on location according to the situation in September 2013. Birth centres differed in their reason for establishment, facilities, philosophies, staffing and service delivery.

  7. Photoionization mass spectrometry for the investigation of combustion generated nascent nanoparticles and their relation to laser induced incandescence

    NASA Astrophysics Data System (ADS)

    Grotheer, H.-H.; Wolf, K.; Hoffmann, K.

    2011-08-01

    Premixed laminar flat ethylene flames were investigated for nascent nanoparticles through photoionization mass spectrometry (PIMS). Using an atmospheric McKenna burner and ethylene air flames coupled to an atmospheric sampling system, within a relatively narrow C/O range two modes of these particles were found, which can be clearly distinguished with regard to their temperature dependence, their reactivity, and their ionization behaviour. Behind a diesel engine the same particles were observed. These results were corroborated using a low pressure ethylene-O2 flame coupled to a high resolution mass spectrometer. In this case, due to a special inlet system, it was possible to operate the flame in a fairly wide C/O range without clogging of the inlet nozzles. This allowed pursuing the development of particle size distribution functions (PSDF) well into the regime of mature soot. In addition, on the low mass side of the particle spectra measurements with unity resolution were possible and this allowed gaining information concerning their growth mechanism and structure. Finally, in an attempt to mimic Laser Induced Incandescence (LII) experiments the soot-laden molecular beam was exposed to IR irradiation. This resulted in a near complete destruction of nascent particles under LII typical fluences. Small C clusters between 3 and 17 C atoms were found. In addition and with much higher intensities, clusters comprising several hundreds of C atoms were also detected, the latter even at very low fluences when small clusters were totally absent.

  8. Evaluation of intermodal passenger transfer facilities

    DOT National Transportation Integrated Search

    1994-09-01

    The Wisconsin Department of Transportation has initiated a study into the feasibility of locating an intermodal passenger transportation facility in downtown Milwaukee. That feasibilty study requires an evaluation of a very wide range of alternatives...

  9. 40 CFR 63.471 - Facility-wide standards.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... manufacture of narrow tubing, and continuous web cleaning machines, located at a major source that are subject... engineering calculations included in the compliance report. (4) Each owner or operator of an affected facility...

  10. 40 CFR 63.471 - Facility-wide standards.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... manufacture of narrow tubing, and continuous web cleaning machines, located at a major source that are subject... engineering calculations included in the compliance report. (4) Each owner or operator of an affected facility...

  11. The 50-horsepower solar-powered irrigation facility located near Gila Bend, Arizona

    NASA Astrophysics Data System (ADS)

    Smith, W. A.; Alexander, G.; Busch, D. F.

    1980-05-01

    The 50 horsepower solar powered irrigation facility near Gila Bend, Arizona which includes a Rankine cycle demonstrates the technical feasibility of solar powered pumping. The design of a facility specifically for the irrigation farmer using the technology that has been developed over the last four years is proposed.

  12. 78 FR 52971 - Notice of Lodging of Consent Decree Pursuant to the Clean Air Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-27

    ... Defendant's coke production facilities located at 400 East Winchester Avenue in Ashland, Kentucky. The Defendant ceased operations at the coke facilities on June 21, 2011. Under this settlement between the... coke facilities are no longer in operation, the Defendant is not required, under this Consent Decree...

  13. 75 FR 11913 - Chrysler, LLC; Warren Stamping Plant, Including On-Site Leased Workers From Caravan Knight...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-12

    ... Stamping Plant, Including On-Site Leased Workers From Caravan Knight Facilities Management LLC; Warren, MI... from Caravan Knight Facilities Management LLC were employed on-site at the Warren, Michigan location of... Department is amending this certification to include workers leased from Caravan Knight Facilities Management...

  14. 78 FR 75293 - Approval and Promulgation of Implementation Plans; State of California; 2012 Los Angeles County...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-11

    ... Angeles County are two large lead-acid battery recycling facilities, Exide Technologies located in the... two large lead-acid battery-recycling facilities--Exide Technologies in Vernon (``Exide'') and... battery recycling facilities (i.e., Exide and Quemetco) as the only sources of lead in the Los Angeles...

  15. The 50-horsepower solar-powered irrigation facility located near Gila Bend, Arizona

    NASA Technical Reports Server (NTRS)

    Smith, W. A.; Alexander, G.; Busch, D. F.

    1980-01-01

    The 50 horsepower solar powered irrigation facility near Gila Bend, Arizona which includes a Rankine cycle demonstrates the technical feasibility of solar powered pumping. The design of a facility specifically for the irrigation farmer using the technology that has been developed over the last four years is proposed.

  16. 40 CFR 63.2334 - Am I subject to this subpart?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) Oil and natural gas production field facilities, as the term “facility” is defined in § 63.761 of subpart HH. (2) Natural gas transmission and storage facilities, as the term “facility” is defined in § 63... distribution operations located at research and development facilities, consistent with section 112(c)(7) of...

  17. TOXIC CHEMICAL RELEASE INVENTORY (TRI) OF FACILITIES IN 1987 TO 1993 BY STATESAND TERRITORIES INCLUDING AMERICAN SAMOA, PUERTO RICO, AND THE VIRGIN ISLANDS

    EPA Science Inventory

    TRI contains data on annual estimated releases of over 300 toxic chemicals to air, water, and land by the manufacturing industry. Industrial facilities provide the information, which includes: the location of the facility where chemicals are manufactured, processed, or otherwise...

  18. 30 CFR 254.27 - What information must I include in the “Dispersant use plan” appendix?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., REGULATION, AND ENFORCEMENT, DEPARTMENT OF THE INTERIOR OFFSHORE OIL-SPILL RESPONSE REQUIREMENTS FOR FACILITIES LOCATED SEAWARD OF THE COAST LINE Oil-Spill Response Plans for Outer Continental Shelf Facilities... the oils handled, stored, or transported at the facility; (b) A summary of toxicity data for these...

  19. Floor vibration evaluations for medical facilities

    NASA Astrophysics Data System (ADS)

    Himmel, Chad N.

    2003-10-01

    The structural floor design for new medical facilities is often selected early in the design phase and in renovation projects, the floor structure already exists. Because the floor structure can often have an influence on the location of vibration sensitive medical equipment and facilities, it is becoming necessary to identify the best locations for equipment and facilities early in the design process. Even though specific criteria for vibration-sensitive uses and equipment may not always be available early in the design phase, it should be possible to determine compatible floor structures for planned vibration-sensitive uses by comparing conceptual layouts with generic floor vibration criteria. Relatively simple evaluations of planned uses and generic criteria, combined with on-site vibration and noise measurements early in design phase, can significantly reduce future design problems and expense. Concepts of evaluation procedures and analyses will be presented in this paper. Generic floor vibration criteria and appropriate parameters to control resonant floor vibration and noise will be discussed for typical medical facilities and medical research facilities. Physical, economic, and logistical limitations that affect implementation will be discussed through case studies.

  20. Settlement preferences in the disaster-prone areas of Brantas River

    NASA Astrophysics Data System (ADS)

    Hariyani, S.

    2018-01-01

    Kota Lama is one of the urban villages in Malang city that has settlements along the Brantas River. Kota Lama experienced three landslides and flooding in 2015 and one in 2016. Those disasters caused the community to take action of post-disaster recovery, yet the people still choose to remain living in Kota Lama. Therefore, the study aims at determining the preferences of the citizens living in disaster-prone areas in Brantas River. The research used a factor analysis of 12 variables: 1) neighbourhood situation, 2) air condition, 3) relations between neighbours, 4) security, 5) location, 6) customs, 7) ethnic diversity, 8) the presence of social groups, 9) the community’s customs and habits, 10) proximity to the economic facilities, 11) adequate educational facilities, and 12) adequate medical/health facilities. The results show that two factors have been formed, namely Factor 1 (access) comprising variables of neighbourhood situation, air condition, relations between neighbours, location, ethnic diversity, the presence of a social group, supporting positive habits at home, close to the economic facilities, educational facilities, as well as medical facilities, and Factor 2 (assurance) consisting of customs and security.

  1. Conceptual design assessment for the co-firing of bio-refinery supplied lignin project. Quarterly report, July 1--September 30, 2000

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Berglund, T.; Ranney, J.T.; Babb, C.L.

    2000-10-01

    The initial design criteria of the MSW to ethanol facility have been completed along with preliminary site identification and layouts for the processing facility. These items are the first step in evaluating the feasibility of this co-located facility. Pilot facility design and modification are underway for the production and dewatering of the lignin fuel. Major process equipment identification has been completed and several key unit operations will be accomplished on rental equipment. Equipment not available for rental or at TVA has been ordered and facility modification and shakedown will begin in October. The study of the interface and resulting impactsmore » on the TVA Colbert facility are underway. The TVA Colbert fossil plant is fully capable of providing a reliable steam supply for the proposed Masada waste processing facility. The preferred supply location in the Colbert steam cycle has been identified as have possible steam pipeline routes to the Colbert boundary. Additional analysis is underway to fully predict the impact of the steam supply on Colbert plant performance and to select a final steam pipeline route.« less

  2. EPM - The European Facility for human physiology research on ISS.

    PubMed

    Rieschel, Mats; Nasca, Rosario; Junk, Peter; Gerhard, Ingo

    2002-07-01

    The European Physiology Modules (EPM) Facility is one of the four major Space Station facilities being developed within the framework of ESA's Microgravity Facilities for Columbus (MFC) programme. In order to allow a wide spectrum of physiological studies in weightlessness conditions, the facility provides the infrastructure to accommodate a variable set of scientific equipment. The initial EPM configuration supports experiments in the fields of neuroscience, bone & muscle research, cardiovascular research and metabolism. The International Space Life Science Working Group (ISLSWG) has recommended co-locating EPM with the 2 NASA Human Research Facility racks.

  3. Race, ethnicity, and noxious facilities: Environmental racism re- examined

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nieves, A.L.; Nieves, L.A.

    1992-10-01

    The charge has been made that hazardous facilities tend to be located in proximity to minority populations. This study uses a facility density measure for three categories of noxious facilities to examine the relationship between facilities and minority population concentrations. County-level data are used in a correlation analysis for African Americans, Hispanics, and Asians in the four major regions of the US. Even controlling for income and housing value, and limiting the data set to urban areas, consistent patterns of moderate to strong association of facility densities with minority population percentages are found.

  4. NASA personnel and facilities involved in Hurricane Katrina medical evacuation

    NASA Image and Video Library

    2005-09-02

    JSC2005-E-36144 (2 September 2005) --- NASA Johnson Space Center Aircraft Operations Hangar 990 at Ellington Field, Houston, has been used as a triage location this week for medical patients evacuated by air from New Orleans to pass through on their way to Houston-area medical facilities. Hundreds of patients have passed through the location so far, as the transfer operations, led by the Veterans Administration and supported by NASA and other agencies, continue.

  5. A facility location model for municipal solid waste management system under uncertain environment.

    PubMed

    Yadav, Vinay; Bhurjee, A K; Karmakar, Subhankar; Dikshit, A K

    2017-12-15

    In municipal solid waste management system, decision makers have to develop an insight into the processes namely, waste generation, collection, transportation, processing, and disposal methods. Many parameters (e.g., waste generation rate, functioning costs of facilities, transportation cost, and revenues) in this system are associated with uncertainties. Often, these uncertainties of parameters need to be modeled under a situation of data scarcity for generating probability distribution function or membership function for stochastic mathematical programming or fuzzy mathematical programming respectively, with only information of extreme variations. Moreover, if uncertainties are ignored, then the problems like insufficient capacities of waste management facilities or improper utilization of available funds may be raised. To tackle uncertainties of these parameters in a more efficient manner an algorithm, based on interval analysis, has been developed. This algorithm is applied to find optimal solutions for a facility location model, which is formulated to select economically best locations of transfer stations in a hypothetical urban center. Transfer stations are an integral part of contemporary municipal solid waste management systems, and economic siting of transfer stations ensures financial sustainability of this system. The model is written in a mathematical programming language AMPL with KNITRO as a solver. The developed model selects five economically best locations out of ten potential locations with an optimum overall cost of [394,836, 757,440] Rs. 1 /day ([5906, 11,331] USD/day) approximately. Further, the requirement of uncertainty modeling is explained based on the results of sensitivity analysis. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Capsule review of the DOE research and development and field facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    1980-09-01

    A description is given of the roles of DOE's headquarters, field offices, major multiprogram laboratories, Energy Technology and Mining Technology Centers, and other government-owned, contractor-operated facilities, which are located in all regions of the US. Descriptions of DOE facilities are given for multiprogram laboratories (12); program-dedicated facilities (biomedical and environmental facilities-12, fossil energy facilities-7, fusion energy facility-1, nuclear development facilities-3, physical research facilities-4, safeguards facility-1, and solar facilities-2); and Production, Testing, and Fabrication Facilities (nuclear materials production facilities-5, weapon testing and fabrication complex-8). Three appendices list DOE field and project offices; DOE field facilities by state or territory, names, addresses,more » and telephone numbers; DOE R and D field facilities by type, contractor names, and names of directors. (MCW)« less

  7. 7 CFR 1735.91 - Location of facilities.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... AGRICULTURE GENERAL POLICIES, TYPES OF LOANS, LOAN REQUIREMENTS-TELECOMMUNICATIONS PROGRAM Requirements for... must be located so that they can be efficiently operated by the borrower and provide adequate security...

  8. Decostar Settlement Information Sheet

    EPA Pesticide Factsheets

    Decostar manufactures parts for automobile manufacturers, including, but not limited to, Nissan, BMW, Hyundai, and EZ Go. The facility is located in Carrollton, Georgia. Decostar has operated at this location since 2003.

  9. NPDES Permit for Soap Creek Associates Wastewater Treatment Facility in Montana

    EPA Pesticide Factsheets

    Under National Pollutant Discharge Elimination System permit number MT-0023183, Soap Creek Associates, Inc. is authorized to discharge from its wastewater treatment facility located in West, Bighorn County, Montana, to Soap Creek.

  10. 76 FR 18748 - Gulf South Pipeline Company, LP; Notice of Application

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-05

    ... abandon by sale to Boardwalk Field Services, LLC (Field Services) the Pettus Lateral Facilities in Bee and... taps, and other associated facilities located in Bee and Refugio Counties, to Field Services. Gulf...

  11. NPDES Permit for Lame Deer Lagoon Wastewater Treatment Facility in Montana

    EPA Pesticide Factsheets

    Final permit authorizes the Northern Cheyenne Utilities Commission to discharge from its Lame Deer Lagoon wastewater treatment facility located in Rosebud County, Montana to Lame Deer Creek, a tributary to Rosebud Creek.

  12. NPDES Permit for City of Polson Wastewater Treatment Facility in Montana

    EPA Pesticide Factsheets

    Under National Pollutant Discharge Elimination System permit number MT-0020559, the City of Polson is authorized to discharge from its wastewater treatment facility located in Lake County, Montana to the Flathead River.

  13. Hazardous Waste Cleanup: Fairchild Republic Company in Farmingdale, New York

    EPA Pesticide Factsheets

    The Fairchild Republic Company facility is located in East Farmingdale, Long Island, New York. This facility manufactured aircraft and related parts from 1931-1987. All process units were clean closed in 1988.

  14. Missouri Smelting Technology, Inc.

    EPA Pesticide Factsheets

    The EPA is providing notice of a proposed Administrative Penalty Assessment against Missouri Smelting Technology, Inc. (MOST), for alleged violations at a facility located at 50 Cherry Blossom Way, Troy, Missouri 63379 (“facility”). The facility is a secon

  15. Radar Training Facility initial validation.

    DOT National Transportation Integrated Search

    1983-05-01

    The Radar Training Facility (RTF), part of the Federal Aviation Administration Academy located at the Oklahoma City Mike Monroney Aeronautical Center, is designed to identify, as early as possible, air traffic control specialists who do not demonstra...

  16. Job attitudes of airway facilities personnel.

    DOT National Transportation Integrated Search

    1977-08-01

    A total of 2,366 employees of the Airway Facilities (AF) Service responded to a detailed questionnaire concerning job satisfaction and such factors as salary, shift schedule, workload, and geographic location. : In general, AF employees reported sati...

  17. Joint Optimization of Distribution Network Design and Two-Echelon Inventory Control with Stochastic Demand and CO2 Emission Tax Charges

    PubMed Central

    Li, Shuangyan; Li, Xialian; Zhang, Dezhi; Zhou, Lingyun

    2017-01-01

    This study develops an optimization model to integrate facility location and inventory control for a three-level distribution network consisting of a supplier, multiple distribution centers (DCs), and multiple retailers. The integrated model addressed in this study simultaneously determines three types of decisions: (1) facility location (optimal number, location, and size of DCs); (2) allocation (assignment of suppliers to located DCs and retailers to located DCs, and corresponding optimal transport mode choices); and (3) inventory control decisions on order quantities, reorder points, and amount of safety stock at each retailer and opened DC. A mixed-integer programming model is presented, which considers the carbon emission taxes, multiple transport modes, stochastic demand, and replenishment lead time. The goal is to minimize the total cost, which covers the fixed costs of logistics facilities, inventory, transportation, and CO2 emission tax charges. The aforementioned optimal model was solved using commercial software LINGO 11. A numerical example is provided to illustrate the applications of the proposed model. The findings show that carbon emission taxes can significantly affect the supply chain structure, inventory level, and carbon emission reduction levels. The delay rate directly affects the replenishment decision of a retailer. PMID:28103246

  18. Molecular detection of canine parvovirus in flies (Diptera) at open and closed canine facilities in the eastern United States.

    PubMed

    Bagshaw, Clarence; Isdell, Allen E; Thiruvaiyaru, Dharma S; Brisbin, I Lehr; Sanchez, Susan

    2014-06-01

    More than thirty years have passed since canine parvovirus (CPV) emerged as a significant pathogen and it continues to pose a severe threat to world canine populations. Published information suggests that flies (Diptera) may play a role in spreading this virus; however, they have not been studied extensively and the degree of their involvement is not known. This investigation was directed toward evaluating the vector capacity of such flies and determining their potential role in the transmission and ecology of CPV. Molecular diagnostic methods were used in this cross-sectional study to detect the presence of CPV in flies trapped at thirty-eight canine facilities. The flies involved were identified as belonging to the house fly (Mucidae), flesh fly (Sarcophagidae) and blow/bottle fly (Calliphoridae) families. A primary surveillance location (PSL) was established at a canine facility in south-central South Carolina, USA, to identify fly-virus interaction within the canine facility environment. Flies trapped at this location were pooled monthly and assayed for CPV using polymerase chain reaction (PCR) methods. These insects were found to be positive for CPV every month from February through the end of November 2011. Fly vector behavior and seasonality were documented and potential environmental risk factors were evaluated. Statistical analyses were conducted to compare the mean numbers of each of the three fly families captured, and after determining fly CPV status (positive or negative), it was determined whether there were significant relationships between numbers of flies captured, seasonal numbers of CPV cases, temperature and rainfall. Flies were also sampled at thirty-seven additional canine facility surveillance locations (ASL) and at four non-canine animal industry locations serving as negative field controls. Canine facility risk factors were identified and evaluated. Statistical analyses were conducted on the number of CPV cases reported within the past year to determine the correlation of fly CPV status (positive or negative) for each facility, facility design (open or closed), mean number of dogs present monthly and number of flies captured. Significant differences occurred between fly CPV positive vs. negative sites with regard to their CPV case numbers, fly numbers captured, and number of dogs present. At the ASL, a statistically significant relationship was found between PCR-determined fly CPV status (positive or negative) and facility design (open vs. closed). Open-facility designs were likely to have more CPV outbreaks and more likely to have flies testing positive for CPV DNA. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. 78 FR 54902 - Agency Information Collection Activities: Proposed Collection; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-06

    ...: (1) collection of information from the total N-MHSS universe of mental health treatment facilities... respondent respondents respondent per response hours Facilities in full-scale N-MHSS universe in 2014 17,000..., 2015, and 2016 \\1\\ Facilities in N-MHSS-Locator Survey universe in 17,000 1 0.42 7,140 2015 Average...

  20. 78 FR 67377 - Agency Information Collection Activities: Submission for OMB Review; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-12

    ... of information from the total N-MHSS universe of mental health treatment facilities during 2014, 2015... respondent respondents respondent per response hours Facilities in full-scale N-MHSS universe in 2014 17,000..., 2015, and 2016 \\1\\ Facilities in N-MHSS-Locator Survey universe in 17,000 1 0.42 7,140 2015 Average...

  1. 32 CFR Appendix A to Part 223 - Procedures for Identifying and Controlling DoD UCNI

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... security measures, including security plans, procedures, and equipment, for the physical protection of DoD... sabotage of DoD SNM, equipment, or facilities (e.g., relative importance of a facility or the location... equipment, for the physical protection of DoD SNM, equipment, or facilities. c. Meet the adverse effects...

  2. IMPACTS OF DIOXIN EMISSIONS FROM THE SHINKAMPO INCINERATOR TO THE U.S. NAVAL AIR FACILITY AT ATSUGI, JAPAN

    EPA Science Inventory

    The United States Naval Air Facility at Atsugi, Japan (NAF Atsugi) is located in the Kanto Plain area on the island of Honshu, Japan. Directly to the south of the facility, in the Tade River Valley, was the Shinkampo Incinerator Complex (SIC). The Incinerator is no longer in op...

  3. The Impact of School Facilities on the Learning Environment

    ERIC Educational Resources Information Center

    Vandiver, Bert

    2011-01-01

    The purpose of this mixed methods study was to examine the impact of the quality of facilities on the educational environment in high schools located in northeast Texas. The intent of this research study was to determine the relationship between school facilities and the school-learning environment. This study was a mixed method research that used…

  4. 30 CFR 254.26 - What information must I include in the “Worst case discharge scenario” appendix?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... ENVIRONMENTAL ENFORCEMENT, DEPARTMENT OF THE INTERIOR OFFSHORE OIL-SPILL RESPONSE REQUIREMENTS FOR FACILITIES LOCATED SEAWARD OF THE COAST LINE Oil-Spill Response Plans for Outer Continental Shelf Facilities § 254.26... the facility that oil could move in a time period that it reasonably could be expected to persist in...

  5. 30 CFR 254.26 - What information must I include in the “Worst case discharge scenario” appendix?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... ENVIRONMENTAL ENFORCEMENT, DEPARTMENT OF THE INTERIOR OFFSHORE OIL-SPILL RESPONSE REQUIREMENTS FOR FACILITIES LOCATED SEAWARD OF THE COAST LINE Oil-Spill Response Plans for Outer Continental Shelf Facilities § 254.26... the facility that oil could move in a time period that it reasonably could be expected to persist in...

  6. 30 CFR 254.26 - What information must I include in the “Worst case discharge scenario” appendix?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... ENVIRONMENTAL ENFORCEMENT, DEPARTMENT OF THE INTERIOR OFFSHORE OIL-SPILL RESPONSE REQUIREMENTS FOR FACILITIES LOCATED SEAWARD OF THE COAST LINE Oil-Spill Response Plans for Outer Continental Shelf Facilities § 254.26... the facility that oil could move in a time period that it reasonably could be expected to persist in...

  7. Index of Nuclear Weapon Effects Simulators. Sanitized

    DTIC Science & Technology

    1983-06-01

    124 TRESTLE Facility ..................................................... 125 Vertical EMP Simulator ( VEMPS ...82171 SIMULATOR: Vertical EMP Simulator ( VEMPS ) TYPE: EMP AGENCY: US Army LOCATION: HOL1.0’od ridge, V, Research Facility POINT OF CONTACT...DESCRIPTION: The VEMPS facility is I radiating elect, asettc pulse (EMP) stilateor used to expose test obJects to the simulated effects of high altitude EIP

  8. 77 FR 38822 - Notice of Availability: Record of Decision for KRoad Moapa Solar Facility

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-29

    ....ER0000 LVRWF1103400] Notice of Availability: Record of Decision for KRoad Moapa Solar Facility AGENCY... Moapa Solar Facility located in Clark County, Nevada. The Secretary of the Interior approved the ROD on... applicant, KRoad Moapa Solar, LLC, (KRoad) filed two right-of-way (ROW) applications to construct a 500 kV...

  9. 40 CFR 60.5401 - What are the exceptions to the equipment leak standards for affected facilities at onshore...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... equipment leak standards for affected facilities at onshore natural gas processing plants? 60.5401 Section... for affected facilities at onshore natural gas processing plants? (a) You may comply with the... is detected. (4)(i) Any pressure relief device that is located in a nonfractionating plant that is...

  10. 40 CFR 60.5401 - What are the exceptions to the equipment leak standards for affected facilities at onshore...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... equipment leak standards for affected facilities at onshore natural gas processing plants? 60.5401 Section... for affected facilities at onshore natural gas processing plants? (a) You may comply with the... is detected. (4)(i) Any pressure relief device that is located in a nonfractionating plant that is...

  11. 76 FR 65753 - Environmental Assessment and Finding of No Significant Impact Related to Exemption of Material...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-24

    ... facility located near Grand View, Idaho. This facility is regulated by the Idaho Department of..., the NRC held a public meeting in the community of Grand View, Idaho, to inform the public and to... disposal facility near Grand View, Idaho. The LLW will be generated as part of decommissioning activities...

  12. 77 FR 74512 - Interim Policy Leasing for Renewable Energy Data Collection Facility on the Outer Continental...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-14

    ... Policy Leasing for Renewable Energy Data Collection Facility on the Outer Continental Shelf off the Coast..., tribes, local governments, and the public in the preparation of an EA. The EA will consider the environmental consequences associated with issuing a lease for an offshore data collection facility located on...

  13. 78 FR 31985 - Atomic Safety and Licensing Board Panel; Before the Licensing Board: G. Paul Bollwerk, III...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-28

    ... authorizes the operation of CBR's existing in situ uranium recovery (ISR) facility near Crawford, Nebraska... operate a satellite ISR facility, the Marsland Expansion Area (MEA) site, which is located in Dawes County, Nebraska, some eleven miles to the southeast of CBR's Crawford central processing facility. In response to...

  14. 78 FR 1851 - Sabine Pass Liquefaction, LLC and Sabine Pass LNG, L.P.; Notice of Intent To Prepare an...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-09

    ... gas liquids (NGL) truck loading facilities. A Project location map depicting the proposed facilities..., metering and send-out facilities; four gas pipeline meter stations; additional workspaces, laydown and... project is further developed. On natural gas projects, the APE at a minimum encompasses all areas subject...

  15. 40 CFR Appendix F to Part 112 - Facility-Specific Response Plan

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... of Contents 1.0Model Facility-Specific Response Plan 1.1Emergency Response Action Plan 1.2Facility.... EC01MR92.015 1.1Emergency Response Action Plan Several sections of the response plan shall be co-located... sections shall be called the Emergency Response Action Plan. The Agency intends that the Action Plan...

  16. Location for the planned Space Experiment Research and Processing Laboratory

    NASA Technical Reports Server (NTRS)

    2000-01-01

    This diagram shows the planned locations of the Space Experiment Research and Processing Laboratory (SERPL) and the Space Station Commerce Park at Kennedy Space Center. The SERPL is a planned 100,000-square-foot laboratory that will provide expanded and upgraded facilities for hosting International Space Station experiment processing. In addition, it will provide better support for other biological and life sciences payload processing at KSC. It will serve as a magnet facility for the planned 400- acre commerce park.

  17. 40. View of dual projector system located in MWOC facility ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    40. View of dual projector system located in MWOC facility in transmitter building no. 102 by Bessler Company. System used to project images in MWOC on backlit screen system with fiber optic electro/mechanical system linked to computer output to indicate information on screen linked with display from projector system. - Clear Air Force Station, Ballistic Missile Early Warning System Site II, One mile west of mile marker 293.5 on Parks Highway, 5 miles southwest of Anderson, Anderson, Denali Borough, AK

  18. Environmental Assessment: Communications-Electronics Research, Development and Engineering Command (CERDEC) Flight Activity Facility at the Joint Base McGuire-Dix-Lakehurst, New Jersey

    DTIC Science & Technology

    2013-01-01

    portions of the original Lakehurst Proving Ground operations, specifically a goat pasture and associated farm buildings, were located within the project...would continue to receive fuel from the centrally managed fuel farm operation located south of Hangar 6. • The facility would connect to existing...Rounds Road. An undated map6 from the Lakehurst Proving Ground era depicts the project study area as a fenced goat pasture. 3.2.1 Zoning and

  19. Recent advances and results from the solid radiochemistry nuclear diagnostic at the National Ignition Facility

    DOE PAGES

    Gharibyan, N.; Shaughnessy, D. A.; Moody, K. J.; ...

    2016-08-05

    The solid debris collection capability at the National Ignition Facility has been expanded to include a third line-of-sight assembly. The solid radiochemistry nuclear diagnostic measurement of the ratio of gold isotopes is dependent on the efficient collection of neutron-activated hohlraum debris by passive metal disks. As a result, the collection of target debris at this new location is more reliable in comparison to the historic locations, and it appears to be independent of collector surface ablation.

  20. Recent advances and results from the solid radiochemistry nuclear diagnostic at the National Ignition Facility.

    PubMed

    Gharibyan, N; Shaughnessy, D A; Moody, K J; Grant, P M; Despotopulos, J D; Faye, S A; Jedlovec, D R; Yeamans, C B

    2016-11-01

    The solid debris collection capability at the National Ignition Facility has been expanded to include a third line-of-sight assembly. The solid radiochemistry nuclear diagnostic measurement of the ratio of gold isotopes is dependent on the efficient collection of neutron-activated hohlraum debris by passive metal disks. The collection of target debris at this new location is more reliable in comparison to the historic locations, and it appears to be independent of collector surface ablation.

  1. Aerial View of NACA's Lewis Flight Propulsion Research Laboratory

    NASA Image and Video Library

    1946-05-21

    The National Advisory Committee for Aeronautics (NACA) Lewis Flight Propulsion Laboratory in Cleveland, Ohio as seen from the west in May 1946. The Cleveland Municipal Airport is located directly behind. The laboratory was built in the early 1940s to resolve problems associated with aircraft engines. The initial campus contained seven principal buildings: the Engine Research Building, hangar, Fuels and Lubricants Building, Administration Building, Engine Propeller Research Building, Altitude Wind Tunnel, and Icing Research Tunnel. These facilities and their associated support structures were located within an area occupying approximately one-third of the NACA’s property. After World War II ended, the NACA began adding new facilities to address different problems associated with the newer, more powerful engines and high speed flight. Between 1946 and 1955, four new world-class test facilities were built: the 8- by 6-Foot Supersonic Wind Tunnel, the Propulsion Systems Laboratory, the Rocket Engine Test Facility, and the 10- by 10-Foot Supersonic Wind Tunnel. These large facilities occupied the remainder of the NACA’s semicircular property. The Lewis laboratory expanded again in the late 1950s and early 1960s as the space program commenced. Lewis purchased additional land in areas adjacent to the original laboratory and acquired a large 9000-acre site located 60 miles to the west in Sandusky, Ohio. The new site became known as Plum Brook Station.

  2. 10 CFR 1.5 - Location of principal offices and Regional Offices.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Location of principal offices and Regional Offices. 1.5 Section 1.5 Energy NUCLEAR REGULATORY COMMISSION STATEMENT OF ORGANIZATION AND GENERAL INFORMATION Introduction § 1.5 Location of principal offices and Regional Offices. (a) The principal NRC offices are located in the Washington, DC, area. Facilities...

  3. 42 CFR 456.605 - Number and location of teams.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 4 2013-10-01 2013-10-01 false Number and location of teams. 456.605 Section 456... Facilities and Institutions for Mental Diseases § 456.605 Number and location of teams. There must be a sufficient number of teams so located within the State that onsite inspections can be made at appropriate...

  4. 42 CFR 456.605 - Number and location of teams.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 4 2012-10-01 2012-10-01 false Number and location of teams. 456.605 Section 456... Facilities and Institutions for Mental Diseases § 456.605 Number and location of teams. There must be a sufficient number of teams so located within the State that onsite inspections can be made at appropriate...

  5. 42 CFR 456.605 - Number and location of teams.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 4 2014-10-01 2014-10-01 false Number and location of teams. 456.605 Section 456... Facilities and Institutions for Mental Diseases § 456.605 Number and location of teams. There must be a sufficient number of teams so located within the State that onsite inspections can be made at appropriate...

  6. 42 CFR 456.605 - Number and location of teams.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 4 2011-10-01 2011-10-01 false Number and location of teams. 456.605 Section 456... Facilities and Institutions for Mental Diseases § 456.605 Number and location of teams. There must be a sufficient number of teams so located within the State that onsite inspections can be made at appropriate...

  7. 42 CFR 456.605 - Number and location of teams.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 4 2010-10-01 2010-10-01 false Number and location of teams. 456.605 Section 456... Facilities and Institutions for Mental Diseases § 456.605 Number and location of teams. There must be a sufficient number of teams so located within the State that onsite inspections can be made at appropriate...

  8. Population-based geographic access to parent and satellite National Cancer Institute Cancer Center Facilities.

    PubMed

    Onega, Tracy; Alford-Teaster, Jennifer; Wang, Fahui

    2017-09-01

    Satellite facilities of National Cancer Institute (NCI) cancer centers have expanded their regional footprints. This study characterized geographic access to parent and satellite NCI cancer center facilities nationally overall and by sociodemographics. Parent and satellite NCI cancer center facilities, which were geocoded in ArcGIS, were ascertained. Travel times from every census tract in the continental United States and Hawaii to the nearest parent and satellite facilities were calculated. Census-based population attributes were used to characterize measures of geographic access for sociodemographic groups. From the 62 NCI cancer centers providing clinical care in 2014, 76 unique parent locations and 211 satellite locations were mapped. The overall proportion of the population within 60 minutes of a facility was 22% for parent facilities and 32.7% for satellite facilities. When satellites were included for potential access, the proportion of some racial groups for which a satellite was the closest NCI cancer center facility increased notably (Native Americans, 22.6% with parent facilities and 39.7% with satellite facilities; whites, 34.8% with parent facilities and 50.3% with satellite facilities; and Asians, 40.0% with parent facilities and 54.0% with satellite facilities), with less marked increases for Hispanic and black populations. Rural populations of all categories had dramatically low proportions living within 60 minutes of an NCI cancer center facility of any type (1.0%-6.6%). Approximately 14% of the population (n = 43,033,310) lived more than 180 minutes from a parent or satellite facility, and most of these individuals were Native Americans and/or rural residents (37% of Native Americans and 41.7% of isolated rural residents). Racial/ethnic and rural populations showed markedly improved geographic access to NCI cancer center care when satellite facilities were included. Cancer 2017;123:3305-11. © 2017 American Cancer Society. © 2017 American Cancer Society.

  9. KENNEDY SPACE CENTER, FLA. - STS-120 Mission Specialists Piers Sellers and Michael Foreman look at the Japanese Experiment Module (JEM) Pressurized Module located in the Space Station Processing Facility. Known as Kibo, the JEM consists of six components: two research facilities -- the Pressurized Module and Exposed Facility; a Logistics Module attached to each of them; a Remote Manipulator System; and an Inter-Orbit Communication System unit. Kibo also has a scientific airlock through which experiments are transferred and exposed to the external environment of space. The various components of JEM will be assembled in space over the course of three Space Shuttle missions. The STS-120 mission will deliver the second of three Station connecting modules, Node 2, which attaches to the end of U.S. Lab. It will provide attach locations for the JEM, European laboratory, the Centrifuge Accommodation Module and later Multi-Purpose Logistics Modules. The addition of Node 2 will complete the U.S. core of the International Space Station.

    NASA Image and Video Library

    2003-07-18

    KENNEDY SPACE CENTER, FLA. - STS-120 Mission Specialists Piers Sellers and Michael Foreman look at the Japanese Experiment Module (JEM) Pressurized Module located in the Space Station Processing Facility. Known as Kibo, the JEM consists of six components: two research facilities -- the Pressurized Module and Exposed Facility; a Logistics Module attached to each of them; a Remote Manipulator System; and an Inter-Orbit Communication System unit. Kibo also has a scientific airlock through which experiments are transferred and exposed to the external environment of space. The various components of JEM will be assembled in space over the course of three Space Shuttle missions. The STS-120 mission will deliver the second of three Station connecting modules, Node 2, which attaches to the end of U.S. Lab. It will provide attach locations for the JEM, European laboratory, the Centrifuge Accommodation Module and later Multi-Purpose Logistics Modules. The addition of Node 2 will complete the U.S. core of the International Space Station.

  10. Hazardous Waste Cleanup: Ortho-Clinical Diagnostics, Raritan, New Jersey

    EPA Pesticide Factsheets

    Ortho-Clinical Diagnostics (OCD) is an administration and manufacturing facility located at 1001 U.S. Route 202 North in Raritan Borough, Somerset County, New Jersey. The facility manufactures hospital and laboratory reagents used primarily for blood

  11. NPDES Permit for Town of Hot Springs Wastewater Treatment Facility in Montana

    EPA Pesticide Factsheets

    Under NPDES permit MT0020591, the Town of Hot Springs, Montana, is authorized to discharge from its wastewater treatment facility located in Sanders County, Montana, to a ditch discharging to Hot Springs Creek.

  12. Iowa City Ready Mix, Inc.

    EPA Pesticide Factsheets

    The EPA is providing notice of a proposed Administrative Penalty Assessment against Iowa City Ready Mix, Inc., for alleged violations at a facility located at 1854 South Riverside, Iowa City, IA (“facility”). The facility produces and transports ready mixe

  13. 77 FR 34950 - Decision To Evaluate a Petition To Designate a Class of Employees From the Clarksville Facility...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-12

    ...: Clarksville Facility. Location: Clarksville, Tennessee. Job Titles and/or Job Duties: Workers potentially..., Division of Compensation Analysis and Support, National Institute for Occupational Safety and Health, 4676...

  14. 47 CFR 15.615 - General administrative requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...-2190.5 kHz. Within the exclusion zone for the Very Large Array radio astronomy observatory, Access BPL... facilities located at the coordinates specified for radio astronomy facilities in 47 CFR 2.106, Note U.S. 311...

  15. 47 CFR 15.615 - General administrative requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...-2190.5 kHz. Within the exclusion zone for the Very Large Array radio astronomy observatory, Access BPL... facilities located at the coordinates specified for radio astronomy facilities in 47 CFR 2.106, Note U.S. 311...

  16. 47 CFR 15.615 - General administrative requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...-2190.5 kHz. Within the exclusion zone for the Very Large Array radio astronomy observatory, Access BPL... facilities located at the coordinates specified for radio astronomy facilities in 47 CFR 2.106, Note U.S. 311...

  17. 47 CFR 15.615 - General administrative requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...-2190.5 kHz. Within the exclusion zone for the Very Large Array radio astronomy observatory, Access BPL... facilities located at the coordinates specified for radio astronomy facilities in 47 CFR 2.106, Note U.S. 311...

  18. 47 CFR 15.615 - General administrative requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...-2190.5 kHz. Within the exclusion zone for the Very Large Array radio astronomy observatory, Access BPL... facilities located at the coordinates specified for radio astronomy facilities in 47 CFR 2.106, Note U.S. 311...

  19. NPDES Permit for Charlo Wastewater Treatment Facility in Montana

    EPA Pesticide Factsheets

    Under NPDES permit MT-0022551, the Consolidated Charlo-Lake County Water & Sewer District is authorized to discharge from its wastewater treatment facility located in Lake County, Montana to an unnamed swale that runs to Dublin Gulch.

  20. Skylab 2 facilities and environmental measurements program

    NASA Technical Reports Server (NTRS)

    1972-01-01

    A list of the facilities and environmental measurements to be monitored in support of the Skylab 2 vehicle is presented. The data include measurement identification number, description, transducer operating range, recorder type, and drawings illustrating measurement location.

  1. Sandia National Laboratories: Locations: Kauai Test Facility

    Science.gov Websites

    Defense Systems & Assessments About Defense Systems & Assessments Program Areas Accomplishments Foundations Bioscience Computing & Information Science Electromagnetics Engineering Science Geoscience Suppliers iSupplier Account Accounts Payable Contract Information Construction & Facilities Contract

  2. 33 CFR 137.65 - Visual inspections of the facility, the real property on which the facility is located, and...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ....65 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE POLLUTION FINANCIAL RESPONSIBILITY AND COMPENSATION OIL SPILL LIABILITY: STANDARDS FOR CONDUCTING ALL...

  3. 33 CFR 137.65 - Visual inspections of the facility, the real property on which the facility is located, and...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ....65 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE POLLUTION FINANCIAL RESPONSIBILITY AND COMPENSATION OIL SPILL LIABILITY: STANDARDS FOR CONDUCTING ALL...

  4. 33 CFR 137.65 - Visual inspections of the facility, the real property on which the facility is located, and...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ....65 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE POLLUTION FINANCIAL RESPONSIBILITY AND COMPENSATION OIL SPILL LIABILITY: STANDARDS FOR CONDUCTING ALL...

  5. 33 CFR 137.65 - Visual inspections of the facility, the real property on which the facility is located, and...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ....65 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE POLLUTION FINANCIAL RESPONSIBILITY AND COMPENSATION OIL SPILL LIABILITY: STANDARDS FOR CONDUCTING ALL...

  6. Environmental Assessment for decommissioning the Strategic Petroleum Reserve Weeks Island Facility, Iberia Parish, Louisiana

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1995-12-01

    The Strategic Petroleum Reserve (SPR) Weeks Island site is one of five underground salt dome crude oils storage facilities operated by the Department of Energy (DOE). It is located in Iberia Parish, Louisiana. The purpose of the proposed action is to decommission the Weeks Island crude oil storage after the oil inventory has been transferred to other SPR facilities. Water intrusion into the salt dome storage chambers and the development of two sinkholes located near the aboveground facilities has created uncertain geophysical conditions. This Environmental Assessment describes the proposed decommissioning operation, its alternatives, and potential environmental impacts. Based on thismore » analyses, DOE has determined that the proposed action is not a major Federal action significantly affecting the quality of the human environment within the meaning of the National Environmental Policy Act (NEPA) and has issued the Finding of No Significant Impact (FONSI).« less

  7. Status of the cyclotron/P.E.T. facility at the State University of New York at Buffalo

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Toorongian, S.A.; Haka, M.S.

    1994-12-31

    A new P.E.T./Cyclotron facility has been constructed on the Main St. campus of the State University of New York at Buffalo to service the needs of Nuclear Medicine departments in Buffalo and throughout the Western New York area. This facility is jointly funded and operated by S.U.N.Y. and the Veterans Administration. The cyclotron, as well as the research labs and a nuclear pharmacy to prepare non-positron emitting radiopharmaceuticals, are located in a newly constructed facility on campus. The P.E.T. scanner is located in the Veterans Administration Hospital adjacent to the campus. The two annexes are connected by a pneumatic transportmore » {open_quotes}rabbit{close_quotes} system. The cyclotron and all radiopharmaceutical synthesis apparatus have been purchased from Ion Beam Applications s.a. of Lovain-la-Neuve Belgium.« less

  8. Results of PBX 9501 and PBX 9502 Round-Robin Quasi-Static Tension Tests from JOWOG-9/39 Focused Exchange.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thompson, D. G.

    2002-01-01

    A round-robin study was conducted with the participation of three laboratory facilities: Los Alamos National Laboratory (LANL), BWXT Pantex Plant (PX), and Lawrence Livermore National Laboratory (LLNL). The study involved the machining and quasi-static tension testing of two plastic-bonded high explosive (PBX) composites, PBX 9501 and PBX 9502. Nine tensile specimens for each type of PBX were to be machined at each of the three facilities; 3 of these specimens were to be sent to each of the participating materials testing facilities for tensile testing. The resultant data was analyzed to look for trends associated with specimen machining location and/ormore » trends associated with materials testing location. The analysis provides interesting insights into the variability and statistical nature of mechanical properties testing on PBX composites. Caution is warranted when results are compared/exchanged between testing facilities.« less

  9. Prevalence and determinants of caesarean section in private and public health facilities in underserved South Asian communities: cross-sectional analysis of data from Bangladesh, India and Nepal

    PubMed Central

    Neuman, Melissa; Alcock, Glyn; Azad, Kishwar; Kuddus, Abdul; Osrin, David; More, Neena Shah; Nair, Nirmala; Tripathy, Prasanta; Sikorski, Catherine; Saville, Naomi; Sen, Aman; Colbourn, Tim; Houweling, Tanja A J; Seward, Nadine; Manandhar, Dharma S; Shrestha, Bhim P; Costello, Anthony; Prost, Audrey

    2014-01-01

    Objectives To describe the prevalence and determinants of births by caesarean section in private and public health facilities in underserved communities in South Asia. Design Cross-sectional study. Setting 81 community-based geographical clusters in four locations in Bangladesh, India and Nepal (three rural, one urban). Participants 45 327 births occurring in the study areas between 2005 and 2012. Outcome measures Proportion of caesarean section deliveries by location and type of facility; determinants of caesarean section delivery by location. Results Institutional delivery rates varied widely between settings, from 21% in rural India to 90% in urban India. The proportion of private and charitable facility births delivered by caesarean section was 73% in Bangladesh, 30% in rural Nepal, 18% in urban India and 5% in rural India. The odds of caesarean section were greater in private and charitable health facilities than in public facilities in three of four study locations, even when adjusted for pregnancy and delivery characteristics, maternal characteristics and year of delivery (Bangladesh: adjusted OR (AOR) 5.91, 95% CI 5.15 to 6.78; Nepal: AOR 2.37, 95% CI 1.62 to 3.44; urban India: AOR 1.22, 95% CI 1.09 to 1.38). We found that highly educated women were particularly likely to deliver by caesarean in private facilities in urban India (AOR 2.10; 95% CI 1.61 to 2.75) and also in rural Bangladesh (AOR 11.09, 95% CI 6.28 to 19.57). Conclusions Our results lend support to the hypothesis that increased caesarean section rates in these South Asian countries may be driven in part by the private sector. They also suggest that preferences for caesarean delivery may be higher among highly educated women, and that individual-level and provider-level factors interact in driving caesarean rates higher. Rates of caesarean section in the private sector, and their maternal and neonatal health outcomes, require close monitoring. PMID:25550293

  10. View of camera station located northeast of Building 70022, facing ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    View of camera station located northeast of Building 70022, facing northwest - Naval Ordnance Test Station Inyokern, Randsburg Wash Facility Target Test Towers, Tower Road, China Lake, Kern County, CA

  11. Environmental Audit of the Environmental Measurements Laboratory (EML)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1992-02-01

    This document contains the findings identified during the Environmental Audit of the Environmental Measurements Laboratory (EML), conducted from December 2 to 13, 1991. The Audit included the EML facility located in a fifth-floor General Services Administration (GSA) office building located in New York City, and a remote environmental monitoring station located in Chester, New Jersey. The scope of this Environmental Audit was comprehensive, covering all areas of environmental activities and waste management operations, with the exception of the National Environmental Policy Act (NEPA), which is the responsibility of the DOE Headquarters Office of NEPA Oversight. Compliance with applicable Federal, state,more » and local requirements; applicable DOE Orders; and internal facility requirements was addressed.« less

  12. Horizontal equity and efficiency at primary health care facilities in rural Afghanistan: a seemingly unrelated regression approach.

    PubMed

    Johns, Benjamin; Steinhardt, Laura; Walker, Damian G; Peters, David H; Bishai, David

    2013-07-01

    Producing services efficiently and equitably are important goals for health systems. Many countries pursue horizontal equity - providing people with the same illnesses equal access to health services - by locating facilities in remote areas. Staff are often paid incentives to work at such facilities. However, there is little evidence on how many fewer people are treated at remote facilities than facilities in more densely settled areas. This research explores if there is an association between the efficiency of health centers in Afghanistan and the remoteness of their location. Survey teams collected data on facility level inputs and outputs at a stratified random sample of 579 health centers in 2005. Quality of care was measured by observing staff interact with patients and determining if staff completed a set of normative patient care tasks. We used seemingly unrelated regression to determine if facilities in remote areas have fewer outpatient visits than other rural facilities. In this analysis, one equation compares the number of outpatient visits to facility inputs, while another compares quality of care to determinants of quality. The results indicate remote facilities have about 13% fewer outpatient visits than non-remote facilities, holding inputs constant. Our analysis suggests that facilities in remote areas are realizing horizontal equity since their clients are receiving comparable quality of care to those at non-remote facilities. However, we find the average labor cost for a visit at a remote facility is $1.44, but only $0.97 at other rural facilities, indicating that a visit in a remote facility would have to be 'worth' 1.49 times a visit at a rural facility for there to be no equity - efficiency trade-off. In determining where to build or staff health centers, this loss of efficiency may be offset by progress toward a social policy objective of providing services to disadvantaged rural populations. Copyright © 2013 Elsevier Ltd. All rights reserved.

  13. Feasibility Investigation for a Solar Power Generation Facility

    NASA Technical Reports Server (NTRS)

    Nathan, Lakshmi

    2010-01-01

    The Energy Policy Act of 2005 states that by fiscal year 2013, at least 7.5% of the energy consumed by the government must be renewable energy. In an effort to help meet this goal, Johnson Space Center (JSC) is considering installing a solar power generation facility. The purpose of this project is to conduct a feasibility investigation for such a facility. Because Kennedy Space Center (KSC) has a solar power generation facility, the first step in this investigation is to learn about KSC's facility and obtain information on how it was constructed. After collecting this information, the following must be determined: the amount of power desired, the size of the facility, potential locations for it, and estimated construction and maintenance costs. Contacts with JSC's energy provider must also be established to determine if a partnership would be agreeable to both parties. Lastly, all of this data must be analyzed to decide whether or not JSC should construct the facility. The results from analyzing the data collected indicate that a 200 kW facility would provide enough energy to meet 1% of JSC's energy demand. This facility would require less than 1 acre of land. In the map below, potential locations are shown in green. The solar power facility is projected to cost $2 M. So far, the information collected indicates that such a facility could be constructed. The next steps in this investigation include contacting JSC's energy provider, CenterPoint Energy, to discuss entering a partnership; developing a life cycle cost analysis to determine payback time; developing more detailed plans; and securing funding.

  14. EVALUATION OF PROMPT DOSE ENVIRONMENT IN THE NATIONAL IGNITION FACILITY DURING D-D AND THD SHOTS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Khater, H; Dauffy, L; Sitaraman, S

    2009-04-28

    Evaluation of the prompt dose environment expected in the National Ignition Facility (NIF) during Deuterium-Deuterium (D-D) and Tritium-Hydrogen-Deuterium (THD) shots have been completed. D-D shots resulting in the production of an annual fusion yield of up to 2.4 kJ (200 shots with 10{sup 13} neutrons per shot) are considered. During the THD shot campaign, shots generating a total of 2 x 10{sup 14} neutrons per shot are also planned. Monte Carlo simulations have been performed to estimate prompt dose values inside the facility as well as at different locations outside the facility shield walls. The Target Chamber shielding, along withmore » Target Bay and Switchyard walls, roofs, and shield doors (when needed) will reduce dose levels in occupied areas to acceptable values during these shot campaigns. The calculated dose values inside occupied areas are small, estimated at 25 and 85 {micro}rem per shot during the D-D and THD shots, respectively. Dose values outside the facility are insignificant. The nearest building to the NIF facility where co-located workers may reside is at a distance of about 100 m from the Target Chamber Center (TCC). The dose in such a building is estimated at a fraction of a ?rem during a D-D or a THD shot. Dose at the nearest site boundary location (350 m from TCC), is caused by skyshine and to a lesser extent by direct radiation. The maximum off-site dose during any of the shots considered is less than 10 nano rem.« less

  15. Evaluating the accuracy of sampling to estimate central line-days: simplification of the National Healthcare Safety Network surveillance methods.

    PubMed

    Thompson, Nicola D; Edwards, Jonathan R; Bamberg, Wendy; Beldavs, Zintars G; Dumyati, Ghinwa; Godine, Deborah; Maloney, Meghan; Kainer, Marion; Ray, Susan; Thompson, Deborah; Wilson, Lucy; Magill, Shelley S

    2013-03-01

    To evaluate the accuracy of weekly sampling of central line-associated bloodstream infection (CLABSI) denominator data to estimate central line-days (CLDs). Obtained CLABSI denominator logs showing daily counts of patient-days and CLD for 6-12 consecutive months from participants and CLABSI numerators and facility and location characteristics from the National Healthcare Safety Network (NHSN). Convenience sample of 119 inpatient locations in 63 acute care facilities within 9 states participating in the Emerging Infections Program. Actual CLD and estimated CLD obtained from sampling denominator data on all single-day and 2-day (day-pair) samples were compared by assessing the distributions of the CLD percentage error. Facility and location characteristics associated with increased precision of estimated CLD were assessed. The impact of using estimated CLD to calculate CLABSI rates was evaluated by measuring the change in CLABSI decile ranking. The distribution of CLD percentage error varied by the day and number of days sampled. On average, day-pair samples provided more accurate estimates than did single-day samples. For several day-pair samples, approximately 90% of locations had CLD percentage error of less than or equal to ±5%. A lower number of CLD per month was most significantly associated with poor precision in estimated CLD. Most locations experienced no change in CLABSI decile ranking, and no location's CLABSI ranking changed by more than 2 deciles. Sampling to obtain estimated CLD is a valid alternative to daily data collection for a large proportion of locations. Development of a sampling guideline for NHSN users is underway.

  16. Scenario-based modeling for multiple allocation hub location problem under disruption risk: multiple cuts Benders decomposition approach

    NASA Astrophysics Data System (ADS)

    Yahyaei, Mohsen; Bashiri, Mahdi

    2017-12-01

    The hub location problem arises in a variety of domains such as transportation and telecommunication systems. In many real-world situations, hub facilities are subject to disruption. This paper deals with the multiple allocation hub location problem in the presence of facilities failure. To model the problem, a two-stage stochastic formulation is developed. In the proposed model, the number of scenarios grows exponentially with the number of facilities. To alleviate this issue, two approaches are applied simultaneously. The first approach is to apply sample average approximation to approximate the two stochastic problem via sampling. Then, by applying the multiple cuts Benders decomposition approach, computational performance is enhanced. Numerical studies show the effective performance of the SAA in terms of optimality gap for small problem instances with numerous scenarios. Moreover, performance of multi-cut Benders decomposition is assessed through comparison with the classic version and the computational results reveal the superiority of the multi-cut approach regarding the computational time and number of iterations.

  17. Efficiency of private and public primary health facilities accredited by the National Health Insurance Authority in Ghana.

    PubMed

    Alhassan, Robert Kaba; Nketiah-Amponsah, Edward; Akazili, James; Spieker, Nicole; Arhinful, Daniel Kojo; Rinke de Wit, Tobias F

    2015-01-01

    Despite improvements in a number of health outcome indicators partly due to the National Health Insurance Scheme (NHIS), Ghana is unlikely to attain all its health-related millennium development goals before the end of 2015. Inefficient use of available limited resources has been cited as a contributory factor for this predicament. This study sought to explore efficiency levels of NHIS-accredited private and public health facilities; ascertain factors that account for differences in efficiency and determine the association between quality care and efficiency levels. The study is a cross-sectional survey of NHIS-accredited primary health facilities (n = 64) in two regions in southern Ghana. Data Envelopment Analysis was used to estimate technical efficiency of sampled health facilities while Tobit regression was employed to predict factors associated with efficiency levels. Spearman correlation test was performed to determine the association between quality care and efficiency. Overall, 20 out of the 64 health facilities (31 %) were optimally efficient relative to their peers. Out of the 20 efficient facilities, 10 (50 %) were Public/government owned facilities; 8 (40 %) were Private-for-profit facilities and 2 (10 %) were Private-not-for-profit/Mission facilities. Mission (Coef. = 52.1; p = 0.000) and Public (Coef. = 42.9; p = 0.002) facilities located in the Western region (predominantly rural) had higher odds of attaining the 100 % technical efficiency benchmark than those located in the Greater Accra region (largely urban). No significant association was found between technical efficiency scores of health facilities and many technical quality care proxies, except in overall quality score per the NHIS accreditation data (Coef. = -0.3158; p < 0.05) and SafeCare Essentials quality score on environmental safety for staff and patients (Coef. = -0.2764; p < 0.05) where the association was negative. The findings suggest some level of wastage of health resources in many healthcare facilities, especially those located in urban areas. The Ministry of Health and relevant stakeholders should undertake more effective need analysis to inform resource allocation, distribution and capacity building to promote efficient utilization of limited resources without compromising quality care standards.

  18. 77 FR 12861 - Agency Information Collection Activities: Proposed Collection; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-02

    ...-MHSS activities: (1) Collection of information from the full N-MHSS universe of mental health treatment...-Locator universe.... 15,000 1 .42 6,300 Newly identified facilities \\1\\ 1,500 1 .42 630 Total Facilities...

  19. Two Springfield, Mass. Facilities Agree to Improve Handling and Reporting of Hazardous Chemicals

    EPA Pesticide Factsheets

    Two facilities located in Springfield, Mass. have agreed with the U.S. EPA to come into compliance with federal requirements designed to protect the public and first responders from exposure to hazardous chemicals.

  20. Utility investigation best practices and effects on TxDOT highway improvement projects.

    DOT National Transportation Integrated Search

    2013-04-01

    The lack of adequate information about the location and characteristics of utility facilities can result in a number of problems, including damages to utilities, disruptions to utility services and traffic, lost utility facilities as constructi...

Top