Sample records for facto dosing practices

  1. The use of de jure to maintain a de facto status quo

    NASA Astrophysics Data System (ADS)

    Gallard Martínez, Alejandro José; Antrop-González, René

    2013-12-01

    The vignette we use as the introduction works to define and distinguish the concepts of de jure and de facto pedagogical actions, especially as related to Latin@ education and its relationship with STEM fields. The authors assert that de jure educational policies, which are often legal guidelines that mandate minimum levels of compliance, unfortunately become translated to mean the normative way to implement educational practice. Hence, going above and beyond the call of duty to educate Latin@ children and youth through culturally meaningful STEM practices while respecting, affirming, and utilizing decolonizing ways of viewing science and math is not viewed as standard. Thus, it is imperative that STEM educators who work with Latin@ learners demand that de jure education guidelines translated as de facto pedagogical actions are not enough. On the contrary, de jure and de facto ways of teaching and learning should always consist of a counterhegemonic normative.

  2. Untangling outcomes of de jure and de facto community-based management of natural resources.

    PubMed

    Agarwala, Meghna; Ginsberg, Joshua R

    2017-12-01

    We systematically reviewed the literature on the tragedy of the commons and common-property resources. We segregated studies by legal management regimes (de jure regimes) and management that develops in practice (de facto regimes) to understand how the structure of regime formation affects the outcome of community management on sustainability of resource use. De facto regimes, developed within the community, are more likely to have positive impacts on the resource. However, de facto regimes are fragile and not resilient in the face of increased population pressure and unregulated markets, and de facto management regimes are less successful where physical exclusion of external agents from resources is more difficult. Yet, formalization or imposition of de jure management regimes can have complicated impacts on sustainability. The imposition of de jure regimes usually has a negative outcome when existing de facto regimes operate at larger scales than the imposed de jure regime. In contrast, de jure regimes have largely positive impacts when the de facto regimes operate at scales smaller than the overlying de jure regimes. Formalization may also be counterproductive because of elite capture and the resulting de facto privatization (that allows elites to effectively exclude others) or de facto open access (where the disenfranchised may resort to theft and elites cannot effectively exclude them). This underscores that although the global movement to formalize community-management regimes may address some forms of inequity and may produce better outcomes, it does not ensure resource sustainability and may lead to greater marginalization of users. Comparison of governance systems that differentiate between initiatives that legitimize existing de facto regimes and systems that create new de facto regimes, investigations of new top-down de jure regimes, and studies that further examine different approaches to changing de jure regimes to de facto regimes are avenues for

  3. What about ex post facto

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McKee, H.C.

    This note presents a legal question in an attempt to find an answer. The author hopes that some legal scholar can explain the principle of ex post facto in the US Constitution as it applies to some of the environmental laws. One of the major advantages of the Association is that it provides a forum for communication among members with different backgrounds and experience. An ex post facto law is one that is applied retroactively. Under such a law, a person could be punished for some act that violated a law passed after the act was committed, even though themore » act was legal when committed. The US Constitution prohibits such laws, as will be discussed later. States are also prohibited from enacting ex post facto laws.« less

  4. 47 CFR 1.9030 - Long-term de facto transfer leasing arrangements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 1 2011-10-01 2011-10-01 false Long-term de facto transfer leasing... PROCEDURE Spectrum Leasing General Policies and Procedures § 1.9030 Long-term de facto transfer leasing...) and a spectrum lessee may enter into a long-term de facto transfer leasing arrangement in which the...

  5. 47 CFR 1.9035 - Short-term de facto transfer leasing arrangements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 1 2011-10-01 2011-10-01 false Short-term de facto transfer leasing... PROCEDURE Spectrum Leasing General Policies and Procedures § 1.9035 Short-term de facto transfer leasing...) and a spectrum lessee may enter into a short-term de facto transfer leasing arrangement in which the...

  6. Practice-Based Research: Ex Post Facto Evaluation of Evidence-Based Police Practices Implemented in Residential Burglary Micro-Time Hot Spots.

    PubMed

    Santos, Roberto G; Santos, Rachel Boba

    2015-10-01

    Police agencies around the country are implementing various strategies to reduce crime in their communities that need to be evaluated. These strategies are often based on systematic crime analysis and are focused on crime occurring in hot spots, which are areas of disproportionate amounts of crime. This article takes a practice-based research approach to evaluate whether evidence-based police strategies implemented by one police agency as its normal everyday crime reduction practice are effective in reducing residential burglary incidents in micro-time hot spots. A quasi-experimental ex post facto design is employed using 5 years of data from one police agency that has institutionalized the identification and response to micro-time hot spots into its day-to-day practices. Propensity score matching is used to match 54 pairs of micro-time hot spots using logistic regression to compute the propensity scores and greedy 1 to 1 matching with a caliper width of 0.5 of the standard deviation of the logit to match the cases. Independent t-tests show that tactical police response to micro-time hot spots can lead to significant reductions in residential burglary incidents without the spatial displacement of crime. Tactical police responses that seek to achieve short-term reductions in crime appear to be well suited for micro-time hot spots since they are, by nature, short term. Importantly, the conclusions are based on the evaluation of an agency's systematic implementation of the evidence-based practices as its normal practices and not for the sake of research. © The Author(s) 2015.

  7. 47 CFR 1.9010 - De facto control standard for spectrum leasing arrangements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 1 2011-10-01 2011-10-01 false De facto control standard for spectrum leasing... PROCEDURE Spectrum Leasing General Policies and Procedures § 1.9010 De facto control standard for spectrum..., the following standard is applied for purposes of determining whether a licensee retains de facto...

  8. 47 CFR 1.9010 - De facto control standard for spectrum leasing arrangements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false De facto control standard for spectrum leasing... PROCEDURE Spectrum Leasing General Policies and Procedures § 1.9010 De facto control standard for spectrum..., the following standard is applied for purposes of determining whether a licensee retains de facto...

  9. 78 FR 40430 - De Facto

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-05

    ... the government in making decisions regarding the selection of management; and (4) whether the... government; (2) export sales negotiations and prices; (3) composition of company management, the process... de facto Test With Requests for Additional Documentary Support and Additional Questions Regarding the...

  10. Ex Post Facto Monte Carlo Variance Reduction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Booth, Thomas E.

    The variance in Monte Carlo particle transport calculations is often dominated by a few particles whose importance increases manyfold on a single transport step. This paper describes a novel variance reduction method that uses a large importance change as a trigger to resample the offending transport step. That is, the method is employed only after (ex post facto) a random walk attempts a transport step that would otherwise introduce a large variance in the calculation.Improvements in two Monte Carlo transport calculations are demonstrated empirically using an ex post facto method. First, the method is shown to reduce the variance inmore » a penetration problem with a cross-section window. Second, the method empirically appears to modify a point detector estimator from an infinite variance estimator to a finite variance estimator.« less

  11. Assessment of De Facto Wastewater Reuse across the US: trends between 1980 and 2008.

    PubMed

    Rice, Jacelyn; Wutich, Amber; Westerhoff, Paul

    2013-10-01

    De facto wastewater reuse is the incidental presence of treated wastewater in a water supply source. In 1980 the EPA identified drinking water treatment plants (DWTPs) impacted by upstream wastewater treatment plant (WWTP) discharges and found the top 25 most impacted DWTPs contained between 2% and 16% wastewater discharges from upstream locations (i.e., de facto reuse) under average streamflow conditions. This study is the first to provide an update to the 1980 EPA analysis. An ArcGIS model of DWTPs and WWTPs across the U.S. was created to quantify de facto reuse for the top 25 cities in the 1980 EPA study. From 1980 to 2008, de facto reuse increased for 17 of the 25 DWTPs, as municipal flows upstream of the sites increased by 68%. Under low streamflow conditions, de facto reuse in DWTP supplies ranged from 7% to 100%, illustrating the importance of wastewater in sustainable water supplies. Case studies were performed on four cities to analyze the reasons for changes in de facto reuse over time. Three of the four sites have greater than 20% treated wastewater effluent within their drinking water source for streamflow less than the 25th percentile historic flow.

  12. 47 CFR 1.9010 - De facto control standard for spectrum leasing arrangements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 1 2012-10-01 2012-10-01 false De facto control standard for spectrum leasing... PROCEDURE Grants by Random Selection Spectrum Leasing General Policies and Procedures § 1.9010 De facto control standard for spectrum leasing arrangements. (a) Under the rules established for spectrum leasing...

  13. 47 CFR 1.9010 - De facto control standard for spectrum leasing arrangements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 1 2014-10-01 2014-10-01 false De facto control standard for spectrum leasing... PROCEDURE Grants by Random Selection Spectrum Leasing General Policies and Procedures § 1.9010 De facto control standard for spectrum leasing arrangements. (a) Under the rules established for spectrum leasing...

  14. 47 CFR 1.9010 - De facto control standard for spectrum leasing arrangements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 1 2013-10-01 2013-10-01 false De facto control standard for spectrum leasing... PROCEDURE Grants by Random Selection Spectrum Leasing General Policies and Procedures § 1.9010 De facto control standard for spectrum leasing arrangements. (a) Under the rules established for spectrum leasing...

  15. Modeled De Facto Reuse and Contaminants of Emerging Concern in Drinking Water Source Waters

    EPA Science Inventory

    De facto reuse is the percentage of drinking water treatment plant (DWTP) intake potentially composed of effluent discharged from upstream wastewater treatment plants (WWTPs). Results from grab samples and a De Facto Reuse in our Nation's Consumable Supply (DRINCS) geospatial wat...

  16. Designing research: ex post facto designs.

    PubMed

    Giuffre, M

    1997-06-01

    The research design is the overall plan or structure of the study. The goal of a good research design is to insure internal validity and answer the question being asked. The only clear rule in selecting a design is that the question dictates the design. Over the next few issues this column will cover types of research designs and their inherent strengths and weaknesses. This article discusses ex post facto research.

  17. A Grassroots Solution to "De Facto" School Segregation.

    ERIC Educational Resources Information Center

    Broderick, Mary

    1997-01-01

    Connecticut is struggling to address the "de facto" desegregation that finds 80% of the state's minority schoolchildren enrolled in only 18 of its 166 school districts. In 1996, the state's supreme court ruled that Connecticut's two-tiered system was violating these students' rights. Southeastern Connecticut's improvement plan reflects…

  18. Exercise Dose in Clinical Practice

    PubMed Central

    Wasfy, Meagan; Baggish, Aaron L.

    2016-01-01

    There is wide variability in the physical activity patterns of the patients in contemporary clinical cardiovascular practice. This review is designed to address the impact of exercise dose on key cardiovascular risk factors and on mortality. We begin by examining the body of literature that supports a dose-response relationship between exercise and cardiovascular disease risk factors including plasma lipids, hypertension, diabetes mellitus, and obesity. We next explore the relationship between exercise dose and mortality by reviewing the relevant epidemiological literature underlying current physical activity guideline recommendations. We then expand this discussion to critically examine recent data pertaining to the impact of exercise dose at the lowest and highest ends of the spectrum. Finally, we provide a framework for how the key concepts of exercise dose can be integrated into clinical practice. PMID:27267537

  19. Implications of Transitioning from De Facto to Engineered Water Reuse for Power Plant Cooling.

    PubMed

    Barker, Zachary A; Stillwell, Ashlynn S

    2016-05-17

    Thermoelectric power plants demand large quantities of cooling water, and can use alternative sources like treated wastewater (reclaimed water); however, such alternatives generate many uncertainties. De facto water reuse, or the incidental presence of wastewater effluent in a water source, is common at power plants, representing baseline conditions. In many cases, power plants would retrofit open-loop systems to cooling towers to use reclaimed water. To evaluate the feasibility of reclaimed water use, we compared hydrologic and economic conditions at power plants under three scenarios: quantified de facto reuse, de facto reuse with cooling tower retrofits, and modeled engineered reuse conditions. We created a genetic algorithm to estimate costs and model optimal conditions. To assess power plant performance, we evaluated reliability metrics for thermal variances and generation capacity loss as a function of water temperature. Applying our analysis to the greater Chicago area, we observed high de facto reuse for some power plants and substantial costs for retrofitting to use reclaimed water. Conversely, the gains in reliability and performance through engineered reuse with cooling towers outweighed the energy investment in reclaimed water pumping. Our analysis yields quantitative results of reclaimed water feasibility and can inform sustainable management of water and energy.

  20. Exercise Dose in Clinical Practice.

    PubMed

    Wasfy, Meagan M; Baggish, Aaron L

    2016-06-07

    There is wide variability in the physical activity patterns of the patients in contemporary clinical cardiovascular practice. This review is designed to address the impact of exercise dose on key cardiovascular risk factors and on mortality. We begin by examining the body of literature that supports a dose-response relationship between exercise and cardiovascular disease risk factors, including plasma lipids, hypertension, diabetes mellitus, and obesity. We next explore the relationship between exercise dose and mortality by reviewing the relevant epidemiological literature underlying current physical activity guideline recommendations. We then expand this discussion to critically examine recent data pertaining to the impact of exercise dose at the lowest and highest ends of the spectrum. Finally, we provide a framework for how the key concepts of exercise dose can be integrated into clinical practice. © 2016 American Heart Association, Inc.

  1. Modeled de facto reuse and contaminants of emerging concern in drinking water source waters

    USGS Publications Warehouse

    Nguyen, Thuy; Westerhoff, Paul; Furlong, Edward T.; Kolpin, Dana W.; Batt, Angela L.; Mash, Heath E.; Schenck, Kathleen M.; Boone, J. Scott; Rice, Jacelyn; Glassmeyer, Susan T.

    2018-01-01

    De facto reuse is the percentage of drinking water treatment plant (DWTP) intake potentially composed of effluent discharged from upstream wastewater treatment plants (WWTPs). Results from grab samples and a De Facto Reuse in our Nation's Consumable Supply (DRINCS) geospatial watershed model were used to quantify contaminants of emerging concern (CECs) concentrations at DWTP intakes to qualitatively compare exposure risks obtained by the two approaches. Between nine and 71 CECs were detected in grab samples. The number of upstream WWTP discharges ranged from 0 to >1,000; comparative de facto reuse results from DRINCS ranged from <0.1 to 13% during average flow and >80% during lower streamflows. Correlation between chemicals detected and DRINCS modeling results were observed, particularly DWTPs withdrawing from midsize water bodies. This comparison advances the utility of DRINCS to identify locations of DWTPs for future CEC sampling and treatment technology testing.

  2. Practical applications of internal dose calculations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carbaugh, E.H.

    1994-06-01

    Accurate estimates of intake magnitude and internal dose are the goal for any assessment of an actual intake of radioactivity. When only one datum is available on which to base estimates, the choices for internal dose assessment become straight-forward: apply the appropriate retention or excretion function, calculate the intake, and calculate the dose. The difficulty comes when multiple data and different types of data become available. Then practical decisions must be made on how to interpret conflicting data, or how to adjust the assumptions and techniques underlying internal dose assessments to give results consistent with the data. This article describesmore » nine types of adjustments which can be incorporated into calculations of intake and internal dose, and then offers several practical insights to dealing with some real-world internal dose puzzles.« less

  3. "De facto" Privatisation of Education and the Poor: Implications of a Study from Sub-Saharan Africa and India

    ERIC Educational Resources Information Center

    Tooley, James; Dixon, Pauline

    2006-01-01

    Three types of privatisation are identified--involving demand-side financing, reforms to the educational supply-side and "de facto" privatisation, where responsibilities are transferred to the private sector, through the rapid growth of private schools, rather than through reform or legislation. Although "de facto"…

  4. Spatial and temporal variation in de facto wastewater reuse in drinking water systems across the U.S.A.

    PubMed

    Rice, Jacelyn; Westerhoff, Paul

    2015-01-20

    De facto potable reuse occurs when treated wastewater is discharged into surface waters upstream of potable drinking water treatment plant (DWTP) intakes. Wastewater treatment plant (WWTP) discharges may pose water quality risks at the downstream DWTP, but additional flow aids in providing a reliable water supply source. In this work de facto reuse is analyzed for 2056 surface water intakes serving 1210 DWTPs across the U.S.A. that serve greater than 10,000 people, covering approximately 82% of the nation’s population. An ArcGIS model is developed to assess spatial relationships between DWTPs and WWTPs, with a python script designed to perform a network analysis by hydrologic region. A high frequency of de facto reuse occurrence was observed; 50% of the DWTP intakes are potentially impacted by upstream WWTP discharges. However, the magnitude of de facto reuse was seen to be relatively low, where 50% of the impacted intakes contained less than 1% treated municipal wastewater under average streamflow conditions. De facto reuse increased greatly under low streamflow conditions (modeled by Q95), with 32 of the 80 sites yielding at least 50% treated wastewater, this portion of the analysis is limited to sites where stream gauge data was readily available.

  5. 47 CFR 1.9035 - Short-term de facto transfer leasing arrangements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... PROCEDURE Grants by Random Selection Spectrum Leasing General Policies and Procedures § 1.9035 Short-term de... any of the included services) and a spectrum lessee may enter into a short-term de facto transfer... the leased spectrum is transferred to the spectrum lessee for the duration of the spectrum leasing...

  6. 47 CFR 1.9035 - Short-term de facto transfer leasing arrangements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... PROCEDURE Grants by Random Selection Spectrum Leasing General Policies and Procedures § 1.9035 Short-term de... any of the included services) and a spectrum lessee may enter into a short-term de facto transfer... the leased spectrum is transferred to the spectrum lessee for the duration of the spectrum leasing...

  7. 47 CFR 1.9035 - Short-term de facto transfer leasing arrangements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... PROCEDURE Grants by Random Selection Spectrum Leasing General Policies and Procedures § 1.9035 Short-term de... any of the included services) and a spectrum lessee may enter into a short-term de facto transfer... the leased spectrum is transferred to the spectrum lessee for the duration of the spectrum leasing...

  8. Patient Dose Management: Focus on Practical Actions

    PubMed Central

    2016-01-01

    Medical radiation is a very important part of modern medicine, and should be only used when needed and optimized. Justification and optimization of radiation examinations must be performed. The first step of reduction of medical exposure is to know the radiation dose in currently performed examinations. This review covers radiation units, how various imaging modalities report dose, and the current status of radiation dose reports and legislation. Also, practical tips that can be applied to clinical practice are introduced. Afterwards, the importance of radiology exposure related education is emphasized and the current status of education for medical personal and the public is explained, and appropriate education strategies are suggested. Commonly asked radiation dose related example questions and answers are provided in detail to allow medical personnel to answer patients. Lastly, we talk about computerized programs that can be used in medical facilities for managing patient dose. While patient dose monitoring and management should be used to decrease and optimize overall radiation dose, it should not be used to assess individual cancer risk. One must always remember that medically justified examinations should always be performed, and unneeded examinations should be avoided in the first place. PMID:26908988

  9. The Use of De Jure to Maintain a De Facto Status Quo

    ERIC Educational Resources Information Center

    Gallard Martínez, Alejandro José; Antrop-González, René

    2013-01-01

    The vignette we use as the introduction works to define and distinguish the concepts of de jure and de facto pedagogical actions, especially as related to Latin@ education and its relationship with STEM fields. The authors assert that de jure educational policies, which are often legal guidelines that mandate minimum levels of compliance,…

  10. Optimizing Radiation Doses for Computed Tomography Across Institutions: Dose Auditing and Best Practices.

    PubMed

    Demb, Joshua; Chu, Philip; Nelson, Thomas; Hall, David; Seibert, Anthony; Lamba, Ramit; Boone, John; Krishnam, Mayil; Cagnon, Christopher; Bostani, Maryam; Gould, Robert; Miglioretti, Diana; Smith-Bindman, Rebecca

    2017-06-01

    Radiation doses for computed tomography (CT) vary substantially across institutions. To assess the impact of institutional-level audit and collaborative efforts to share best practices on CT radiation doses across 5 University of California (UC) medical centers. In this before/after interventional study, we prospectively collected radiation dose metrics on all diagnostic CT examinations performed between October 1, 2013, and December 31, 2014, at 5 medical centers. Using data from January to March (baseline), we created audit reports detailing the distribution of radiation dose metrics for chest, abdomen, and head CT scans. In April, we shared reports with the medical centers and invited radiology professionals from the centers to a 1.5-day in-person meeting to review reports and share best practices. We calculated changes in mean effective dose 12 weeks before and after the audits and meeting, excluding a 12-week implementation period when medical centers could make changes. We compared proportions of examinations exceeding previously published benchmarks at baseline and following the audit and meeting, and calculated changes in proportion of examinations exceeding benchmarks. Of 158 274 diagnostic CT scans performed in the study period, 29 594 CT scans were performed in the 3 months before and 32 839 CT scans were performed 12 to 24 weeks after the audit and meeting. Reductions in mean effective dose were considerable for chest and abdomen. Mean effective dose for chest CT decreased from 13.2 to 10.7 mSv (18.9% reduction; 95% CI, 18.0%-19.8%). Reductions at individual medical centers ranged from 3.8% to 23.5%. The mean effective dose for abdominal CT decreased from 20.0 to 15.0 mSv (25.0% reduction; 95% CI, 24.3%-25.8%). Reductions at individual medical centers ranged from 10.8% to 34.7%. The number of CT scans that had an effective dose measurement that exceeded benchmarks was reduced considerably by 48% and 54% for chest and abdomen, respectively. After

  11. 198 AAAAI Survey on Immunotherapy Practice Patterns Concerning Dosing, Dose-Adjustment after Missed Doses and Duration of Immunotherapy

    PubMed Central

    Linnemann, Désirée Larenas; Gupta, Payel; Mithani, Sima; Ponda, Punita

    2012-01-01

    Background Several practical issues dealing with the exact application of allergen immunotherapy (AIT) among European and US allergists are not well known. Guidelines on AIT give recommendations and suggestions for only some of them. We present this unique survey with worldwide response. Methods The AAAAI immunotherapy committee conducted a web-based practice patterns survey (program: Survey Monkey) among all members in&outside US on dosing, dose-adjustment after missed doses and duration of AIT. Results 1201 Returned questionnaires (almost 25% response rate). 21% were non-US-Canada members. Maintenance doses in USCan are (mean/median): Dermatophagoides farinae (Df) combined with Dermatophagoides pteronyssinus (Dpt): 2155/1000AU; Df solo 2484/1000AU. Dpt when combined with Df 1937/1000AU; Dpt solo: 2183/1000AU.Cat 3224/2000BAU. Grass 11,410/4000BAU. 57-65% of the dosing falls within the recommended Practice Parameters recommended ranges. Non-USCan allergists expressed maintenance doses in many different units making analysis impossible. Dose-adjustment after missed doses is based on ‘time elapsed since the last applied dose’ by 77% of USCan and 58% of non-USCan allergists and on ‘time since missed scheduled dose’ by the rest. Doses are adjusted when a patient comes in more than 14 d/5 wk after the last administration at build-up/maintenance by both USCan and non-USCan colleagues. The mostly followed dose-adjustment schedules after 1, 2, 3 missed doses are: Build-up: repeat last dose, reduce by one dose, reduce by 2 doses; maintenance: reduce by one dose, reduce by 2 doses, reduce by 3 doses. 26% uses a different approach reducing doses by a certain percentage or volume. AIT is restarted after a gap in build-up of >30 days and of >12 weeks during maintenance in both groups (median). Outside USCan AIT is prescribed for 3 years (Median). However, 75% of USCan allergists prescribes AIT for 5 years. Main reasons why to continue AIT beyond 5 years:

  12. De Facto Versus de Jure Political Institutions in the Long-Run: A Multivariate Analysis, 1820-2000.

    PubMed

    Foldvari, Peter

    2017-01-01

    In this paper we use the components of the PolityIV project's polity2 and Vanhanen's Index of Democracy indicators to analyse the relationship between de jure and de facto political institutions from 1820 until 2000 with a canonical correlation method corrected for the sample selection bias. We find considerable fluctuation in the relationship between the two measures. After a moderate positive correlation found during the first half of the nineteenth century, the two measures become statistically unrelated until the 1940s. The relationship becomes strong and positive only in the second half of the twentieth century. The relationship between de jure and de facto political institutions hence can be described as a U-curve, reminiscent to an inverse Kuznets-curve.

  13. Legally White, Socially "Mexican": The Politics of De Jure and De Facto School Segregation in the American Southwest

    ERIC Educational Resources Information Center

    Donato, Ruben; Hanson, Jarrod S.

    2012-01-01

    The history of Mexican American school segregation is complex, often misunderstood, and currently unresolved. The literature suggests that Mexican Americans experienced de facto segregation because it was local custom and never sanctioned at the state level in the American Southwest. However, the same literature suggests that Mexican Americans…

  14. Drivers of Microbial Risk for Direct Potable Reuse and de Facto Reuse Treatment Schemes: The Impacts of Source Water Quality and Blending.

    PubMed

    Chaudhry, Rabia M; Hamilton, Kerry A; Haas, Charles N; Nelson, Kara L

    2017-06-13

    Although reclaimed water for potable applications has many potential benefits, it poses concerns for chemical and microbial risks to consumers. We present a quantitative microbial risk assessment (QMRA) Monte Carlo framework to compare a de facto water reuse scenario (treated wastewater-impacted surface water) with four hypothetical Direct Potable Reuse (DPR) scenarios for Norovirus, Cryptosporidium , and Salmonella . Consumer microbial risks of surface source water quality (impacted by 0-100% treated wastewater effluent) were assessed. Additionally, we assessed risks for different blending ratios (0-100% surface water blended into advanced-treated DPR water) when source surface water consisted of 50% wastewater effluent. De facto reuse risks exceeded the yearly 10 -4 infections risk benchmark while all modeled DPR risks were significantly lower. Contamination with 1% or more wastewater effluent in the source water, and blending 1% or more wastewater-impacted surface water into the advanced-treated DPR water drove the risk closer to the 10 -4 benchmark. We demonstrate that de facto reuse by itself, or as an input into DPR, drives microbial risks more so than the advanced-treated DPR water. When applied using location-specific inputs, this framework can contribute to project design and public awareness campaigns to build legitimacy for DPR.

  15. Drivers of Microbial Risk for Direct Potable Reuse and de Facto Reuse Treatment Schemes: The Impacts of Source Water Quality and Blending

    PubMed Central

    Chaudhry, Rabia M.; Hamilton, Kerry A.; Haas, Charles N.; Nelson, Kara L.

    2017-01-01

    Although reclaimed water for potable applications has many potential benefits, it poses concerns for chemical and microbial risks to consumers. We present a quantitative microbial risk assessment (QMRA) Monte Carlo framework to compare a de facto water reuse scenario (treated wastewater-impacted surface water) with four hypothetical Direct Potable Reuse (DPR) scenarios for Norovirus, Cryptosporidium, and Salmonella. Consumer microbial risks of surface source water quality (impacted by 0–100% treated wastewater effluent) were assessed. Additionally, we assessed risks for different blending ratios (0–100% surface water blended into advanced-treated DPR water) when source surface water consisted of 50% wastewater effluent. De facto reuse risks exceeded the yearly 10−4 infections risk benchmark while all modeled DPR risks were significantly lower. Contamination with 1% or more wastewater effluent in the source water, and blending 1% or more wastewater-impacted surface water into the advanced-treated DPR water drove the risk closer to the 10−4 benchmark. We demonstrate that de facto reuse by itself, or as an input into DPR, drives microbial risks more so than the advanced-treated DPR water. When applied using location-specific inputs, this framework can contribute to project design and public awareness campaigns to build legitimacy for DPR. PMID:28608808

  16. Use of a Simplified Nomogram to Individualize Digoxin Dosing versus Standard Dosing Practices in Patients with Heart Failure

    PubMed Central

    DiDomenico, Robert J.; Bress, Adam P.; Na-Thalang, Kwanta; Tsao, Yvonne Y.; Groo, Vicki L.; Deyo, Kelly L.; Patel, Shitalben R.; Bishop, Jeffrey R.; Bauman, Jerry L.

    2014-01-01

    Study Objectives To compare the frequency of achieving a therapeutic serum digoxin concentration (SDC), defined as 0.5–0.9 ng/ml, by using a simplified nomogram to individualize digoxin dosing with standard dosing practices in patients with heart failure, and to characterize the relationship between genetic polymorphisms of the ABCB1 gene and SDC. Design Prospective study with a historical control group. Setting Outpatient care center of an urban academic medical center. Patients One hundred thirty-one adults with heart failure due to left ventricular dysfunction who were treated with digoxin. Intervention Digoxin doses were determined either by the dosing nomogram (65 patients) or standard care (SC; 66 patients) by using a historical controls who were randomly selected from a list of SDCs obtained from laboratory records and who had their digoxin doses determined by standard dosing practices. Measurements and Main Results The primary end point was the proportion of patients achieving a steady-state SDC of 0.5–0.9 ng/ml; secondary end points were mean SDC and proportion of patients achieving a steady-state SDC < 1.0 ng/ml. Postdistributive steady-state SDCs were measured 2–4 weeks after digoxin dosage adjustment or initiation. Therapeutic SDCs were achieved with similar frequency in both groups (38.7% in the nomogram group vs. 34.5% in the SC group, p=0.65); however, more patients in the nomogram group had SDCs < 1.0 ng/ml than in the SC group (85.0% vs. 44.9%, p<0.001). Mean daily digoxin doses were lower in nomogram group (149 ± 67 mcg vs. 177 ± 74 mcg, p=0.02), resulting in lower mean SDCs compared with those in the SC group (0.52 ± 0.30 ng/ml vs. 1.12 ± 0.58 ng/ml, p<0.001). Patients in the pharmacogenetic substudy provided blood samples for genotyping of three common ABCB1 single nucleotide polymorphisms: C1236T (rs1128503), G2677T/A (rs2032582), and C3435T (rs1045642). SDCs were not significantly associated with ABCB1 genotypes. Conclusion Our

  17. De facto molecular weight distributions of glucans by size-exclusion chromatography combined with mass/molar-detection of fluorescence labeled terminal hemiacetals.

    PubMed

    Praznik, Werner; Huber, Anton

    2005-09-25

    A major capability of polysaccharides in aqueous media is their tendency for aggregation and dynamic formation of supermolecular structures. Even extended dissolution processes will not eliminate these structures which dominate many analytical approaches, in particular absolute molecular weight determinations referring to light scattering data. An alternative approach for determination of de facto molecular weight for glucans with free terminal hemiacetal functionality (reducing end group) has been adjusted from carbohydrates for midrange and high-dp glucans: quantitative and stabilized labeling as aminopyridyl-derivatives (AP-glucans) and subsequent analysis of SEC-separated elution profiles based on simultaneously monitored mass and molar fractions by refractive index and fluorescence detection. SEC-DRI/FL of AP-glucans proved as an appropriate approach for determination of de facto molecular weight of constituting glucan molecules even in the presence of supermolecular structures for non-branched (pullulan), branched (dextran), narrow distributed and broad distributed and for mixes of compact and loose packed polymer coils (starch glucan hydrolizate).

  18. Conformity of commercial oral single solid unit dose packages in hospital pharmacy practice.

    PubMed

    Thibault, Maxime; Prot-Labarthe, Sonia; Bussières, Jean-François; Lebel, Denis

    2008-06-01

    There are limited published data on the labelling of single unit dose packages in hospitals. The study was conducted in three large hospitals (two adult and one paediatric) in the metropolitan Montreal area, Quebec, Canada. The objective is to evaluate the labelling of commercial oral single solid unit dose packages available in Canadian urban hospital pharmacy practice. The study endpoint was the labelling conformity of each unit dose package for each criterion and overall for each manufacturer. Complete labelling of unit dose packages should include the following information: (1) brand name, (2) international non-proprietary name or generic name, (3) dosage, (4) pharmaceutical form, (5) manufacturer's name, (6) expiry date, (7) batch number and (8) drug identification number. We also evaluated the ease with which a single unit dose package is detached from a multiple unit dose package for quick, easy and safe use by pharmacy staff. Conformity levels were compared between brand-name and generic packages. A total of 124 different unit dose packages were evaluated. The level of conformity of each criterion varied between 19 and 50%. Only 43% of unit dose packages provided an easy-to-detach system for single doses. Among the 14 manufacturers with three or more unit dose packages evaluated, eight (57%) had a conformity level less than 50%. This study describes the conformity of commercial oral single solid unit dose packages in hospital pharmacy practice in Quebec. A large proportion of unit dose packages do not conform to a set of nine criteria set out in the guidelines of the American Society of Health-System Pharmacists and the Canadian Society of Hospital Pharmacists.

  19. An Ex Post Facto Study Exploring the Impact of Parental Level of Education and Parental Support on First-Year College Adjustment

    ERIC Educational Resources Information Center

    Huntley, Kristy M.

    2011-01-01

    This study explored the impact that parental levels of education and parental support have on college adjustment for first-year students. An ex post facto design was used to examine parental level of education and parental support as variables. Parental level of education is a categorical variable based on report from the student. Parental support…

  20. Best Practices for Intrathecal Baclofen Therapy: Dosing and Long-Term Management.

    PubMed

    Boster, Aaron L; Adair, Roy L; Gooch, Judith L; Nelson, Mary Elizabeth S; Toomer, Andrea; Urquidez, Joe; Saulino, Michael

    2016-08-01

    Intrathecal baclofen (ITB) therapy aims to reduce spasticity and provide functional control. An expert panel consulted on best practices. Pump fill and drug delivery can be started intraoperatively, with monitoring for at least eight hours. Initiate with the 500 mcg/mL concentration. The starting daily dose should be twice the effective bolus screening dose, or the screening dose if the patient had a prolonged response (greater than eight hours) or negative reactions. Oral antispasmodics can be weaned, one drug at a time beginning with oral baclofen after ITB begins. Assessment should occur within 24 hours of a dose change. For adults, daily dose increases may be 5% to 15% once every 24 hours for cerebral-origin spasticity and 10% to 30% once every 24 hours for spinal-origin spasticity. Daily dose increases can be 5% to 15% once every 24 hours for children. Inpatients should be assessed at least every 24 hours and receive rehabilitation. Step dosing can be used for outpatients who cannot return daily. Dosing options include simple continuous dosing, variable 24-hour flex dosing, or regularly scheduled boluses. Patients/caregivers should understand the care plan, responsibilities, and possible side-effects. Low-reservoir alarm dates and refill schedules should be written down, along with emergency contact information. A higher concentration at refill can extend refill intervals, and a bridge bolus must be programmed. Time changes may affect flex dosing. Pump replacement should be scheduled at least three months in advance. ITB dosing is multistep and individualized. © 2016 International Neuromodulation Society.

  1. An evaluation of the impact of digital imaging on radiographic practice and patient doses

    NASA Astrophysics Data System (ADS)

    Horrocks, J.; Violaki, K.

    2015-09-01

    Direct digital imaging technology was implemented in all areas in general and mobile radiology at Barts and the Royal London Hospitals in 2012. Evidence from recent radiation incident investigations indicates optimum exposure factors are not consistently selected, with the greater dynamic range of the digital detectors allowing sub-optimal practice. To investigate further patient dose data were extracted from the Radiology Information System for adult chest X-ray examinations in 2014, covering over 50,000 studies in the Trust. Chest X-ray examinations were selected as they are low dose but frequent examinations. The patient dose data were evaluated taking into account X-ray system type and detector performance measurements, and individual cases studies were used to highlight where practice can be improved.

  2. Dose Adjustment for Normal Eating (DAFNE) in routine clinical practice: who benefits?

    PubMed

    Keen, A J A; Duncan, E; McKillop-Smith, A; Evans, N D; Gold, A E

    2012-05-01

    To explore the effectiveness of Dose Adjustment for Normal Eating in routine clinical practice in the UK. Participants were 124 adults with Type 1 diabetes who had completed a Dose Adjustment for Normal Eating course. Data were collected before the course and again 1 year later on a variety of biological, psychological and social measures. There were a range of significant benefits consistent with Dose Adjustment for Normal Eating aims, including: better control among those with baseline HbA(1c) ≥ 81 mmol/mol (9.6%) (z = -2.8, P = 0.004); reduced number of participants reporting severe hypoglycaemia (χ² = 4.27, P = 0.039); total eradication of diabetic ketoacidosis (χ² = 4.17, P = 0.041) and lower diabetes-related distress (z = -4.5, P < 0.001). The most deprived of the clinic population were significantly under-represented (χ² = 17.8, P = 0.001) and the levels of clinical depression were unusually low. These results indicate that Dose Adjustment for Normal Eating delivered in routine clinical practice is associated with a range of benefits and that certain clinical and psychosocial characteristics are associated with better outcomes. © 2011 The Authors. Diabetic Medicine © 2011 Diabetes UK.

  3. Studies on the Multi-functional Nature of Courses in Economics and the Role of Domain Specific Expertise. Ex Post Facto Research 1.

    ERIC Educational Resources Information Center

    Dochy, F. J. R. C.; Bouwens, M. R. J.

    This paper reports an investigation that was done ex post facto, examining the hypothesis that within economics courses defined economics students achieved better results than did law students in the same courses. This should not be the case if the courses are truly multifunctional. Information on an economics and money course and a course on the…

  4. Initial Performance of the Aspect System on the Chandra Observatory: Post-Facto Aspect Reconstruction

    NASA Technical Reports Server (NTRS)

    Aldcroft, T.; Karovska, M.; Cresitello-Dittmar, M.; Cameron, R.

    2000-01-01

    The aspect system of the Chandra Observatory plays a key role in realizing the full potential of Chandra's x-ray optics and detectors. To achieve the highest spatial and spectral resolution (for grating observations), an accurate post-facto time history of the spacecraft attitude and internal alignment is needed. The CXC has developed a suite of tools which process sensor data from the aspect camera assembly and gyroscopes, and produce the spacecraft aspect solution. In this poster, the design of the aspect pipeline software is briefly described, followed by details of aspect system performance during the first eight months of flight. The two key metrics of aspect performance are: image reconstruction accuracy, which measures the x-ray image blurring introduced by aspect; and celestial location, which is the accuracy of detected source positions in absolute sky coordinates.

  5. Yellow Fever Vaccine Booster Doses: Recommendations of the Advisory Committee on Immunization Practices, 2015.

    PubMed

    Staples, J Erin; Bocchini, Joseph A; Rubin, Lorry; Fischer, Marc

    2015-06-19

    On February 26, 2015, the Advisory Committee on Immunization Practices (ACIP) voted that a single primary dose of yellow fever vaccine provides long-lasting protection and is adequate for most travelers. ACIP also approved recommendations for at-risk laboratory personnel and certain travelers to receive additional doses of yellow fever vaccine (Box). The ACIP Japanese Encephalitis and Yellow Fever Vaccines Workgroup evaluated published and unpublished data on yellow fever vaccine immunogenicity and safety. The evidence for benefits and risks associated with yellow fever vaccine booster doses was evaluated using the Grading of Recommendations, Assessment, Development, and Evaluation (GRADE) framework. This report summarizes the evidence considered by ACIP and provides the updated recommendations for yellow fever vaccine booster doses.

  6. Optimal methotrexate dose is associated with better clinical outcomes than non-optimal dose in daily practice: results from the ESPOIR early arthritis cohort.

    PubMed

    Gaujoux-Viala, Cécile; Rincheval, Nathalie; Dougados, Maxime; Combe, Bernard; Fautrel, Bruno

    2017-12-01

    Although methotrexate (MTX) is the consensual first-line disease-modifying antirheumatic drug (DMARD) for rheumatoid arthritis (RA), substantial heterogeneity remains with its prescription and dosage, which are often not optimal. To evaluate the symptomatic and structural impact of optimal MTX dose in patients with early RA in daily clinical practice over 2 years. Patients included in the early arthritis ESPOIR cohort who fulfilled the ACR-EULAR (American College of Rheumatology/European League against Rheumatism) criteria for RA and received MTX as a first DMARD were assessed. Optimal MTX dose was defined as ≥10 mg/week during the first 3 months, with escalation to ≥20 mg/week or 0.3 mg/kg/week at 6 months without Disease Activity Score in 28 joints remission. Symptomatic and structural efficacy with and without optimal MTX dose was assessed by generalised logistic regression with adjustment for appropriate variables. Within the first year of follow-up, 314 patients (53%) with RA received MTX as a first DMARD (mean dose 12.2±3.8 mg/week). Only 26.4% (n=76) had optimal MTX dose. After adjustment, optimal versus non-optimal MTX dose was more efficient in achieving ACR-EULAR remission at 1 year (OR 4.28 (95% CI 1.86 to 9.86)) and normal functioning (Health Assessment Questionnaire ≤0.5; OR at 1 year 4.36 (95% CI 2.03 to 9.39)), with no effect on radiological progression. Results were similar during the second year. Optimal MTX dose is more efficacious than non-optimal dose for remission and function in early arthritis in daily practice, with no impact on radiological progression over 2 years. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  7. Current modeling practice may lead to falsely high benchmark dose estimates.

    PubMed

    Ringblom, Joakim; Johanson, Gunnar; Öberg, Mattias

    2014-07-01

    Benchmark dose (BMD) modeling is increasingly used as the preferred approach to define the point-of-departure for health risk assessment of chemicals. As data are inherently variable, there is always a risk to select a model that defines a lower confidence bound of the BMD (BMDL) that, contrary to expected, exceeds the true BMD. The aim of this study was to investigate how often and under what circumstances such anomalies occur under current modeling practice. Continuous data were generated from a realistic dose-effect curve by Monte Carlo simulations using four dose groups and a set of five different dose placement scenarios, group sizes between 5 and 50 animals and coefficients of variations of 5-15%. The BMD calculations were conducted using nested exponential models, as most BMD software use nested approaches. "Non-protective" BMDLs (higher than true BMD) were frequently observed, in some scenarios reaching 80%. The phenomenon was mainly related to the selection of the non-sigmoidal exponential model (Effect=a·e(b)(·dose)). In conclusion, non-sigmoid models should be used with caution as it may underestimate the risk, illustrating that awareness of the model selection process and sound identification of the point-of-departure is vital for health risk assessment. Copyright © 2014 The Authors. Published by Elsevier Inc. All rights reserved.

  8. 75 FR 78676 - De Facto Criteria for Establishing a Separate Rate in Antidumping Proceedings Involving Non...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-16

    ...In antidumping proceedings involving non-market economy (``NME'') countries,\\1\\ the Department of Commerce (``the Department'') has a rebuttable presumption that the export activities of all companies within the country are subject to government control and, thus, should be assessed a single antidumping duty rate (i.e., the NME- Entity rate). It is the Department's policy to assign to all exporters of merchandise subject to investigation in an NME country this single rate unless an exporter can demonstrate that it is sufficiently independent so as to be entitled to a ``separate rate'' (i.e., a dumping margin separate from the margin assigned to the NME-Entity). Exporters can demonstrate this independence through the absence of both de jure and de facto governmental control over their export activities. ---------------------------------------------------------------------------

  9. A practical method to standardise and optimise the Philips DoseRight 2.0 CT automatic exposure control system.

    PubMed

    Wood, T J; Moore, C S; Stephens, A; Saunderson, J R; Beavis, A W

    2015-09-01

    Given the increasing use of computed tomography (CT) in the UK over the last 30 years, it is essential to ensure that all imaging protocols are optimised to keep radiation doses as low as reasonably practicable, consistent with the intended clinical task. However, the complexity of modern CT equipment can make this task difficult to achieve in practice. Recent results of local patient dose audits have shown discrepancies between two Philips CT scanners that use the DoseRight 2.0 automatic exposure control (AEC) system in the 'automatic' mode of operation. The use of this system can result in drifting dose and image quality performance over time as it is designed to evolve based on operator technique. The purpose of this study was to develop a practical technique for configuring examination protocols on four CT scanners that use the DoseRight 2.0 AEC system in the 'manual' mode of operation. This method used a uniform phantom to generate reference images which form the basis for how the AEC system calculates exposure factors for any given patient. The results of this study have demonstrated excellent agreement in the configuration of the CT scanners in terms of average patient dose and image quality when using this technique. This work highlights the importance of CT protocol harmonisation in a modern Radiology department to ensure both consistent image quality and radiation dose. Following this study, the average radiation dose for a range of CT examinations has been reduced without any negative impact on clinical image quality.

  10. Assessment of Students Attitude and Perception of Teaching Practice: The Case of Undergraduates of Delta State University, Abraka

    ERIC Educational Resources Information Center

    Ifeoma, Asiyai Romina

    2016-01-01

    This descriptive survey research employed ex-post facto design to examine teaching practice in Delta State University, Abraka Nigeria. Interview and questionnaire were used to generate data from 280 respondents. Three research questions and three hypotheses guided the investigation. Data collected were analyzed via the use of mean, standard…

  11. Elementary Teachers' Perceived Use of Culturally Responsive Teaching Practices and Their Relationship to Teachers' Demographics

    ERIC Educational Resources Information Center

    Hohensee, Jo-Anne

    2013-01-01

    The quantitative ex post facto study had a two-fold purpose: (1) to determine which of the cultural responsive teaching practices of kindergarten through sixth grade teachers were used most often and (2) to determine to what extent each of the teacher's demographics (i.e., the predictive variables) differ for each CRTI factor (i.e., the criterion…

  12. Leadership Aspects of Hidden Curriculum Students Practice in Nigerian Universities: A Preview of Students' Union Government Contributions in University Governance

    ERIC Educational Resources Information Center

    Emesini, Nnenna Orieoma

    2016-01-01

    The paper examined the leadership aspect of Hidden Curriculum that students practice in Nigerian Universities and their contributions to university governance. Four research questions guided the study and Ex-Post-Facto Method was adopted as the design. Unstructured interviews with staff/students officials cum critical analysis of Students' Union…

  13. The Relationship between Scores of Mathematics Knowledge and Teaching Practice of Diploma Mathematics Students: A Quest for Quality Assurance

    ERIC Educational Resources Information Center

    Adamu, L. E.

    2015-01-01

    The purpose of the study was to determine the relationship between scores in mathematics knowledge and teaching practice of Diploma mathematics students. A sample of 39 students was used. Two research questions and two hypotheses were asked and formulated respectively. An ex-post facto correlation design was used. The data were analyzed using…

  14. An ex post facto evaluation framework for place-based police interventions.

    PubMed

    Braga, Anthony A; Hureau, David M; Papachristos, Andrew V

    2011-12-01

    A small but growing body of research evidence suggests that place-based police interventions generate significant crime control gains. While place-based policing strategies have been adopted by a majority of U.S. police departments, very few agencies make a priori commitments to rigorous evaluations. Recent methodological developments were applied to conduct a rigorous ex post facto evaluation of the Boston Police Department's Safe Street Team (SST) hot spots policing program. A nonrandomized quasi-experimental design was used to evaluate the violent crime control benefits of the SST program at treated street segments and intersections relative to untreated street segments and intersections. Propensity score matching techniques were used to identify comparison places in Boston. Growth curve regression models were used to analyze violent crime trends at treatment places relative to control places. UNITS OF ANALYSIS: Using computerized mapping and database software, a micro-level place database of violent index crimes at all street segments and intersections in Boston was created. Yearly counts of violent index crimes between 2000 and 2009 at the treatment and comparison street segments and intersections served as the key outcome measure. The SST program was associated with a statistically significant reduction in violent index crimes at the treatment places relative to the comparison places without displacing crime into proximate areas. To overcome the challenges of evaluation in real-world settings, evaluators need to continuously develop innovative approaches that take advantage of new theoretical and methodological approaches.

  15. Efficiency of adalimumab, etanercept and infliximab in rheumatoid arthritis patients: dosing patterns and effectiveness in daily clinical practice.

    PubMed

    Ramírez-Herráiz, Esther; Escudero-Vilaplana, Vicente; Alañón-Plaza, Estefanía; Trovato-López, Nicolás; Herranz-Alonso, Ana; Morell-Baladrón, Alberto; Sanjurjo-Sáez, María

    2013-01-01

    This retrospective, multicentre, observational study aimed to assess the mean annual doses and associated costs of three anti-tumour necrosis factor agents in daily clinical practice in rheumatoid arthritis patients, correlating these costs with disease activity. Adult rheumatoid arthritis patients were treated and followed at the Rheumatology departments of two Spanish hospitals for at least 6 months, with adalimumab, etanercept or infliximab over a 4-year period. ANOVA and multivariate statistical analyses of dosing patterns, disease activity and annualised costs were carried out. A total of 198 patients, comprising 215 cases, met the inclusion criteria (73 on adalimumab, 81 etanercept and 61 infliximab). Compared to recommended doses, mean doses of adalimumab and etanercept decreased by 7% and 19%, respectively, while the mean dose of infliximab increased by 36%. There were no statistical differences between treatments in terms of clinical effectiveness. The hazard of dose escalation was significantly higher for either adalimumab (4.4-fold) or infliximab (11.8-fold) compared to etanercept (p<0.05). Clinical control was achieved and maintained in more than half of the patients treated with reduced doses of etanercept. Associated mean patient-year costs were significantly higher in adalimumab patients (€11.962.58) (etanercept €9.594.73; infliximab €10.094.53; [p<0.05]). In rheumatoid arthritis patients, it is possible to reduce doses and associated costs of biological therapies while controlling disease activity. Mean doses used in our clinical practice were significantly lower with etanercept than with the anti-TNF monoclonal antibodies, adalimumab and infliximab. Dose differences impact directly on associated patient-year costs, and thus on treatment efficiency.

  16. Iron dosing in kidney disease: inconsistency of evidence and clinical practice

    PubMed Central

    Gaweda, Adam E.; Ginzburg, Yelena Z.; Chait, Yossi; Germain, Michael J.; Aronoff, George R.; Rachmilewitz, Eliezer

    2015-01-01

    The management of anemia in patients with chronic kidney disease (CKD) is difficult. The availability of erythropoiesis-stimulating agents (ESAs) has increased treatment options for previously transfusion-requiring patients, but the recent evidence of ESA side effects has prompted the search for complementary or alternative approaches. Next to ESA, parenteral iron supplementation is the second main form of anemia treatment. However, as of now, no systematic approach has been proposed to balance the concurrent administration of both agents according to individual patient's needs. Furthermore, the potential risks of excessive iron dosing remain a topic of controversy. How, when and whether to monitor CKD patients for potential iron overload remain to be elucidated. This review addresses the question of risk and benefit of iron administration in CKD, highlights the evidence supporting current practice, provides an overview of standard and potential new markers of iron status and outlines a new pharmacometric approach to physiologically compatible individualized dosing of ESA and iron in CKD patients. PMID:24821751

  17. Instructional Supervisory Practices and Teachers' Role Effectiveness in Public Secondary Schools in Calabar South Local Government Area of Cross River State, Nigeria

    ERIC Educational Resources Information Center

    Sule, Mary Anike; Eyiene, Ameh; Egbai, Mercy E.

    2015-01-01

    The study investigated the relationship between instructional supervisory practices and teachers' role effectiveness in public secondary schools in Calabar South Local Government Area of Cross River State. Two null hypotheses were formulated to guide the study. Ex-post facto research design was adopted for the study. The population of the study…

  18. Nuclear cardiology practice and associated radiation doses in Europe: results of the IAEA Nuclear Cardiology Protocols Study (INCAPS) for the 27 European countries.

    PubMed

    Lindner, Oliver; Pascual, Thomas N B; Mercuri, Mathew; Acampa, Wanda; Burchert, Wolfgang; Flotats, Albert; Kaufmann, Philipp A; Kitsiou, Anastasia; Knuuti, Juhani; Underwood, S Richard; Vitola, João V; Mahmarian, John J; Karthikeyan, Ganesan; Better, Nathan; Rehani, Madan M; Kashyap, Ravi; Dondi, Maurizio; Paez, Diana; Einstein, Andrew J

    2016-04-01

    Nuclear cardiology is widely used to diagnose coronary artery disease and to guide patient management, but data on current practices, radiation dose-related best practices, and radiation doses are scarce. To address these issues, the IAEA conducted a worldwide study of nuclear cardiology practice. We present the European subanalysis. In March 2013, the IAEA invited laboratories across the world to document all SPECT and PET studies performed in one week. The data included age, gender, weight, radiopharmaceuticals, injected activities, camera type, positioning, hardware and software. Radiation effective dose was calculated for each patient. A quality score was defined for each laboratory as the number followed of eight predefined best practices with a bearing on radiation exposure (range of quality score 0 - 8). The participating European countries were assigned to regions (North, East, South, and West). Comparisons were performed between the four European regions and between Europe and the rest-of-the-world (RoW). Data on 2,381 European patients undergoing nuclear cardiology procedures in 102 laboratories in 27 countries were collected. A cardiac SPECT study was performed in 97.9 % of the patients, and a PET study in 2.1 %. The average effective dose of SPECT was 8.0 ± 3.4 mSv (RoW 11.4 ± 4.3 mSv; P < 0.001) and of PET was 2.6 ± 1.5 mSv (RoW 3.8 ± 2.5 mSv; P < 0.001). The mean effective doses of SPECT and PET differed between European regions (P < 0.001 and P = 0.002, respectively). The mean quality score was 6.2 ± 1.2, which was higher than the RoW score (5.0 ± 1.1; P < 0.001). Adherence to best practices did not differ significantly among the European regions (range 6 to 6.4; P = 0.73). Of the best practices, stress-only imaging and weight-adjusted dosing were the least commonly used. In Europe, the mean effective dose from nuclear cardiology is lower and the average quality score is higher than in the

  19. Assessment of knowledge, attitude, and practices on fixed dose combinations among postgraduate dental students.

    PubMed

    Vinnakota, Narayana R; Krishna, V; Viswanath, V; Ahmed, Zaheer; Shaik, Kamal S; Boppana, Naveen K

    2016-12-01

    To assess the knowledge, attitude, and practices of fixed dose combination drugs among postgraduate dental students. A cross-sectional study was carried out among postgraduate dental students of dental colleges in coastal Andhra Pradesh. Three colleges were randomly selected and students of all the three years were included. Data was collected from the specialities of oral medicine and radiology, oral surgery, endodontics, pedodontics, periodontics, and public health dentistry. The total sample was 90 postgraduate students; informed consent was obtained from the participants, and a pretested questionnaire was distributed to them. Data was analyzed using the Statistical Package for the Social Sciences version 20 software. Out of 90 postgraduates, 33 were males and 57 were females. Thirty-five percent were aware of the essential medical list (EML), among them 11% were from oral medicine and radiology and 6.7% were from pedodontics. However, most of them were unaware of the number of fixed dose combination drugs present in the World Health Organization EML. None of them were able to name at least a single banned fixed dose combination drug. Most of them were unaware of the advantages and disadvantages of using fixed dose combination drugs. Amoxicillin with clavulanic acid was the most common drug prescribed by students (73.3%) followed by ofloxacin with ornidazole (54.4%), ibuprofen with paracetamol (53.3%), and sulfamethoxazole with trimethoprim (6%). Most of them were unaware of the rationality in using fixed dose combination drugs. Common sources of information were medical representatives 43 (47.8%), internet 39 (43.3%), and 12 (13.3%) reported using WHO EML. There is an urgent need to improve knowledge on the rationality for using fixed dose combination, EML, and banned fixed dose combination in India to the promote rational use of fixed dose combination.

  20. A practical approach to determine dose metrics for nanomaterials.

    PubMed

    Delmaar, Christiaan J E; Peijnenburg, Willie J G M; Oomen, Agnes G; Chen, Jingwen; de Jong, Wim H; Sips, Adriënne J A M; Wang, Zhuang; Park, Margriet V D Z

    2015-05-01

    Traditionally, administered mass is used to describe doses of conventional chemical substances in toxicity studies. For deriving toxic doses of nanomaterials, mass and chemical composition alone may not adequately describe the dose, because particles with the same chemical composition can have completely different toxic mass doses depending on properties such as particle size. Other dose metrics such as particle number, volume, or surface area have been suggested, but consensus is lacking. The discussion regarding the most adequate dose metric for nanomaterials clearly needs a systematic, unbiased approach to determine the most appropriate dose metric for nanomaterials. In the present study, the authors propose such an approach and apply it to results from in vitro and in vivo experiments with silver and silica nanomaterials. The proposed approach is shown to provide a convenient tool to systematically investigate and interpret dose metrics of nanomaterials. Recommendations for study designs aimed at investigating dose metrics are provided. © 2015 SETAC.

  1. An Ex-Post Facto Examination of Relationships among the Developmental Designs Professional Development Model/Classroom Management Approach, School Leadership, Climate, Student Achievement, Attendance, and Behavior in High Poverty, Middle Grades Schools

    ERIC Educational Resources Information Center

    Hough, David L.; Schmitt, Vicki L.

    2011-01-01

    This study reports finding from an ex post facto causal-comparison study utilizing data from a multifaceted program evaluation of a professional development approach to classroom management known as Development Designs 1 and Developmental Designs 2 (DD1 & D2). Data from this program evaluation indicate that teachers implement a number of classroom…

  2. Maintenance dose conversion between oral risperidone and paliperidone palmitate 1 month: Practical guidance based on pharmacokinetic simulations.

    PubMed

    Russu, Alberto; Kern Sliwa, Jennifer; Ravenstijn, Paulien; Singh, Arun; Mathews, Maju; Kim, Edward; Gopal, Srihari

    2018-06-01

    We assessed the dosage strengths of paliperidone palmitate 1-month (PP1M) long-acting injectable resulting in similar steady-state (SS) exposures to the dosage strengths of oral risperidone using pharmacokinetic (PK) simulations. Population PK simulations of SS PK were performed using the PK models of oral risperidone and PP1M. The concentrations of active moiety (risperidone + paliperidone) from risperidone were compared to paliperidone concentrations resulting from PP1M administration. Similarity was assessed via graphical evaluation of median and 90% prediction intervals of SS PK profiles over 28 days. Oral risperidone doses of 1, 2, 3, 4, and 6 mg/d are expected to result in similar SS PK as PP1M doses of 25, 50, 75, 100, and 150 mg eq. (which correspond to 39, 78, 117, 156, and 234 mg of paliperidone palmitate) respectively (ie 25-fold dose conversion factor from oral risperidone to PP1M). This study provides clinicians with a practical guidance to establish suitable maintenance dose levels of PP1M and oral risperidone when transitioning patients from one formulation to another. © 2018 The Authors. International Journal of Clinical Practice Published by John Wiley & Sons Ltd.

  3. Applying rapid 'de-facto' HTA in resource-limited settings: experience from Romania.

    PubMed

    Lopert, Ruth; Ruiz, Francis; Chalkidou, Kalipso

    2013-10-01

    In attempting to constrain healthcare expenditure growth, health technology assessment (HTA) can enable policy-makers to look beyond budget impact and facilitate more rational decision-making. However lack of technical capacity and poor governance can limit use in some countries. Undertaking de facto HTA by adapting decisions taken in countries with established processes is a method that may be applied while building domestic HTA capacity. We explored the potential for applying this approach in Romania. As part of a review of the basic health benefits available to insured Romanians we examined the listing process and content of the Romanian drug reimbursement formulary. We assessed value for money indirectly by drawing on appraisals by UK's NICE, and for products considered cost effective in the UK, adjusting prices by the ratio of Romanian per capita GDP to UK per capita GDP. We found more than 30 of the top 50 medicines on the Romanian formulary unlikely to be cost-effective, suggesting that existing external reference pricing mechanisms may not be delivering good value for money. While not taking into account local costs or treatment patterns, absent local considerations of value for money, this method offers a guide for both drug selection and pricing. Until robust local HTA processes are established this approach could support further analysis of existing prices and pricing mechanisms. Applied more generally, it is arguably preferable to external reference pricing, product delisting or arbitrary price cuts, and may support the future development of more rigorous, evidence-based decision-making. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  4. Dose distribution for dental cone beam CT and its implication for defining a dose index

    PubMed Central

    Pauwels, R; Theodorakou, C; Walker, A; Bosmans, H; Jacobs, R; Horner, K; Bogaerts, R

    2012-01-01

    Objectives To characterize the dose distribution for a range of cone beam CT (CBCT) units, investigating different field of view sizes, central and off-axis geometries, full or partial rotations of the X-ray tube and different clinically applied beam qualities. The implications of the dose distributions on the definition and practicality of a CBCT dose index were assessed. Methods Dose measurements on CBCT devices were performed by scanning cylindrical head-size water and polymethyl methacrylate phantoms, using thermoluminescent dosemeters, a small-volume ion chamber and radiochromic films. Results It was found that the dose distribution can be asymmetrical for dental CBCT exposures throughout a homogeneous phantom, owing to an asymmetrical positioning of the isocentre and/or partial rotation of the X-ray source. Furthermore, the scatter tail along the z-axis was found to have a distinct shape, generally resulting in a strong drop (90%) in absorbed dose outside the primary beam. Conclusions There is no optimal dose index available owing to the complicated exposure geometry of CBCT and the practical aspects of quality control measurements. Practical validation of different possible dose indices is needed, as well as the definition of conversion factors to patient dose. PMID:22752320

  5. Spatial heterogeneity in fishing creates de facto refugia for endangered Celtic Sea elasmobranchs.

    PubMed

    Shephard, Samuel; Gerritsen, Hans; Kaiser, Michel J; Reid, David G

    2012-01-01

    The life history characteristics of some elasmobranchs make them particularly vulnerable to fishing mortality; about a third of all species are listed by the IUCN as Threatened or Near Threatened. Marine Protected Areas (MPAs) have been suggested as a tool for conservation of elasmobranchs, but they are likely to be effective only if such populations respond to fishing impacts at spatial-scales corresponding to MPA size. Using the example of the Celtic Sea, we modelled elasmobranch biomass (kg h(-1)) in fisheries-independent survey hauls as a function of environmental variables and 'local' (within 20 km radius) fishing effort (h y(-1)) recorded from Vessel Monitoring Systems data. Model selection using AIC suggested strongest support for linear mixed effects models in which the variables (i) fishing effort, (ii) geographic location and (iii) demersal fish assemblage had approximately equal importance in explaining elasmobranch biomass. In the eastern Celtic Sea, sampling sites that occurred in the lowest 10% of the observed fishing effort range recorded 10 species of elasmobranch including the critically endangered Dipturus spp. The most intensely fished 10% of sites had only three elasmobranch species, with two IUCN listed as Least Concern. Our results suggest that stable spatial heterogeneity in fishing effort creates de facto refugia for elasmobranchs in the Celtic Sea. However, changes in the present fisheries management regime could impair the refuge effect by changing fisher's behaviour and displacing effort into these areas.

  6. Spatial Heterogeneity in Fishing Creates de facto Refugia for Endangered Celtic Sea Elasmobranchs

    PubMed Central

    Shephard, Samuel; Gerritsen, Hans; Kaiser, Michel J.; Reid, David G.

    2012-01-01

    The life history characteristics of some elasmobranchs make them particularly vulnerable to fishing mortality; about a third of all species are listed by the IUCN as Threatened or Near Threatened. Marine Protected Areas (MPAs) have been suggested as a tool for conservation of elasmobranchs, but they are likely to be effective only if such populations respond to fishing impacts at spatial-scales corresponding to MPA size. Using the example of the Celtic Sea, we modelled elasmobranch biomass (kg h−1) in fisheries-independent survey hauls as a function of environmental variables and ‘local’ (within 20 km radius) fishing effort (h y−1) recorded from Vessel Monitoring Systems data. Model selection using AIC suggested strongest support for linear mixed effects models in which the variables (i) fishing effort, (ii) geographic location and (iii) demersal fish assemblage had approximately equal importance in explaining elasmobranch biomass. In the eastern Celtic Sea, sampling sites that occurred in the lowest 10% of the observed fishing effort range recorded 10 species of elasmobranch including the critically endangered Dipturus spp. The most intensely fished 10% of sites had only three elasmobranch species, with two IUCN listed as Least Concern. Our results suggest that stable spatial heterogeneity in fishing effort creates de facto refugia for elasmobranchs in the Celtic Sea. However, changes in the present fisheries management regime could impair the refuge effect by changing fisher's behaviour and displacing effort into these areas. PMID:23166635

  7. Center of cancer systems biology second annual workshop--tumor metronomics: timing and dose level dynamics.

    PubMed

    Hahnfeldt, Philip; Hlatky, Lynn; Klement, Giannoula Lakka

    2013-05-15

    Metronomic chemotherapy, the delivery of doses in a low, regular manner so as to avoid toxic side effects, was introduced over 12 years ago in the face of substantial clinical and preclinical evidence supporting its tumor-suppressive capability. It constituted a marked departure from the classic maximum-tolerated dose (MTD) strategy, which, given its goal of rapid eradication, uses dosing sufficiently intense to require rest periods between cycles to limit toxicity. Even so, upfront tumor eradication is frequently not achieved with MTD, whereupon a de facto goal of longer-term tumor control is often pursued. As metronomic dosing has shown tumor control capability, even for cancers that have become resistant to the same drug delivered under MTD, the question arises whether it may be a preferable alternative dosing approach from the outset. To date, however, our knowledge of the coupled dynamics underlying metronomic dosing is neither sufficiently well developed nor widely enough disseminated to establish its actual potential. Meeting organizers thus felt the time was right, armed with new quantitative approaches, to call a workshop on "Tumor Metronomics: Timing and Dose Level Dynamics" to explore prospects for gaining a deeper, systems-level appreciation of the metronomics concept. The workshop proved to be a forum in which experts from the clinical, biologic, mathematical, and computational realms could work together to clarify the principles and underpinnings of metronomics. Among other things, the need for significant shifts in thinking regarding endpoints to be used as clinical standards of therapeutic progress was recognized. ©2013 AACR.

  8. The Relationship of Genetics, Nursing Practice, and Informatics Tools in 6-Mercaptopurine Dosing in Pediatric Oncology [Formula: see text].

    PubMed

    Haylett, Wendy J

    An antileukemic agent prescribed for pediatric oncology patients during the maintenance phase of therapy for acute lymphoblastic leukemia, 6-mercaptopurine (6-MP), is highly influenced by genetic variations in the thiopurine S-methyltransferase enzyme. As such, 6-MP must be dosed so that patients with 1 or 2 inactive thiopurine S-methyltransferase alleles will not incur an increased risk for myelosuppression or other toxicities. Informatics tools such as clinical decision support systems are useful for the application of this and similar pharmacogenetics information to the realm of nursing and clinical practice for safe and effective patient care. This article will discuss pharmacogenetics and the associated use of 6-MP; present implications for nursing practice; identify informatics tools such as clinical decision support systems, which can greatly enhance the care of patients whose treatment is based on critical genetic information; and examine the relationship of genetics, nursing practice, and informatics for 6-MP dosing in pediatric oncology.

  9. Tramadol/Paracetamol Fixed-Dose Combination for Chronic Pain Management in Family Practice: A Clinical Review

    PubMed Central

    Morón Merchante, Ignacio; Pergolizzi, Joseph V.; van de Laar, Mart; Mellinghoff, Hans-Ulrich; O'Brien, Joanne; Perrot, Serge; Raffa, Robert B.

    2013-01-01

    The family practitioner plays an important role in the prevention, diagnosis, and early management of chronic pain. He/she is generally the first to be consulted, the one most familiar with the patients and their medical history, and is likely the first to be alerted in case of inadequate pain control or safety and tolerability issues. The family practitioner should therefore be at the center of the multidisciplinary team involved in a patient's pain management. The most frequent indications associated with chronic pain in family practice are of musculoskeletal origin, and the pain is often multimechanistic. Fixed-dose combination analgesics combine compounds with different mechanisms of action; their broader analgesic spectrum and potentially synergistic analgesic efficacy and improved benefit/risk ratio might thus be useful. A pain specialist meeting held in November 2010 agreed that the fixed-dose combination tramadol/paracetamol might be a useful pharmacological option for chronic pain management in family practice. The combination is effective in a variety of pain conditions with generally good tolerability. Particularly in elderly patients, it might be considered as an alternative to conventional analgesics such as NSAIDs, which should be used rarely with caution in this population. PMID:24959571

  10. Vascular access cannulation in hemodialysis patients - a survey of current practice and its relation to dialysis dose.

    PubMed

    Gauly, Adelheid; Parisotto, Maria Teresa; Skinder, Aleksandra; Schoder, Volker; Furlan, Andreja; Schuh, Erika; Marcelli, Daniele

    2011-01-01

    The appropriate use of vascular access is of fundamental importance in the treatment of hemodialysis (HD) patients. This survey entailed collecting data on current practice of vascular access cannulation to assess its relation to dialysis dose. This international, multicenter, observational, cross-sectional survey was performed in 171 dialysis centers of the European dialysis network of Fresenius Medical Care in Europe and South Africa during April 2009. Practice patterns of vascular access cannulations were documented by means of a 24-item questionnaire. Dialysis dose from the documented hemodialysis treatments was derived from the clinical database EuCliD®. In total, 10,807 cannulations in hemodialysis patients with either arteriovenous fistula (91%) or arteriovenous graft (9%) were documented. For the puncture, the area technique was applied most frequently using 15G and 16G needles. Blood flow rates were mostly between 300 and 400 mL/min and adjusted to the needle size used. In two-thirds of cases the arterial needle was placed first, mostly in an antegrade direction, with an average distance to the venous needle of 7.0±3.7 cm. More than two-thirds of the cannulations were performed by nurses with more than 5 years of experience in dialysis. A logistic regression model revealed a significantly higher odds ratio to attain Kt/V = 1.2 for retrograde placement of the arterial needle, and for using needles with bigger diameter. This survey covered a broad number of countries and centers and provides information on current practice of vascular access cannulation, their effect on dialysis dose, and serves as feedback to the dialysis centers for their quality management process.

  11. Effects and Dose-Response Relationships of Motor Imagery Practice on Strength Development in Healthy Adult Populations: a Systematic Review and Meta-analysis.

    PubMed

    Paravlic, Armin H; Slimani, Maamer; Tod, David; Marusic, Uros; Milanovic, Zoran; Pisot, Rado

    2018-05-01

    Motor imagery (MI), a mental simulation of a movement without overt muscle contraction, has been largely used to improve general motor tasks. However, the effects of MI practice on maximal voluntary strength (MVS) remain equivocal. The aims of this meta-analysis were to (1) estimate whether MI practice intervention can meaningfully improve MVS in healthy adults; (2) compare the effects of MI practice on MVS with its combination with physical practice (MI-C), and with physical practice (PP) training alone; and (3) investigate the dose-response relationships of MI practice. Seven electronic databases were searched up to April 2017. Initially 717 studies were identified; however, after evaluation of the study characteristics, data from 13 articles involving 370 participants were extracted. The meta-analysis was completed on MVS as the primary parameter. In addition, parameters associated with training volume, training intensity, and time spent training were used to investigate dose-response relationships. MI practice moderately improved MVS. When compared to conventional PP, effects were of small benefit in favour of PP. MI-C when compared to PP showed unclear effects. MI practice produced moderate effects in both upper and lower extremities on MVS. The cortical representation area of the involved muscles did not modify the effects. Meta-regression analysis revealed that (a) a training period of 4 weeks, (b) a frequency of three times per week, (c) two to three sets per single session, (d) 25 repetitions per single set, and (e) single session duration of 15 min were associated with enhanced improvements in muscle strength following MI practice. Similar dose-response relationships were observed following MI and PP. The present meta-analysis demonstrates that compared to a no-exercise control group of healthy adults, MI practice increases MVS, but less than PP. These findings suggest that MI practice could be considered as a substitute or additional training tool to

  12. WE-F-201-00: Practical Guidelines for Commissioning Advanced Brachytherapy Dose Calculation Algorithms

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    2015-06-15

    With the recent introduction of heterogeneity correction algorithms for brachytherapy, the AAPM community is still unclear on how to commission and implement these into clinical practice. The recently-published AAPM TG-186 report discusses important issues for clinical implementation of these algorithms. A charge of the AAPM-ESTRO-ABG Working Group on MBDCA in Brachytherapy (WGMBDCA) is the development of a set of well-defined test case plans, available as references in the software commissioning process to be performed by clinical end-users. In this practical medical physics course, specific examples on how to perform the commissioning process are presented, as well as descriptions of themore » clinical impact from recent literature reporting comparisons of TG-43 and heterogeneity-based dosimetry. Learning Objectives: Identify key clinical applications needing advanced dose calculation in brachytherapy. Review TG-186 and WGMBDCA guidelines, commission process, and dosimetry benchmarks. Evaluate clinical cases using commercially available systems and compare to TG-43 dosimetry.« less

  13. Evaluation of low-dose CT implementation for lung cancer screening in a general practice hospital

    NASA Astrophysics Data System (ADS)

    Karostik, D. V.; Kamyshanskaya, I. G.; Cheremisin, V. M.; Drozdov, A. A.; Vodovatov, A. V.

    2018-02-01

    The aim of the current study was to evaluate the possibility of the implementation of LDCT for the screening for lung cancer and tuberculosis in a typical general hospital practice. Diagnostic and economic effectiveness, patient doses and the corresponding radiation risks for LDCT were compared with the existing digital chest screening radiography. The results of the study indicate that the implementation of LDCT allowed verifying false-positive cases or providing additional excessive diagnostic information, but did not significantly improve the sensitivity of screening. Per capita costs for LDCT were higher compared to digital radiography up to a factor of 12; corresponding radiation risk - by a factor of 4. Hence, it was considered unjustified to implement LDCT in a general practice hospital.

  14. De Facto Language Education Policy through Teachers' Attitudes and Practices: A Critical Ethnographic Study in Three Jamaican Schools

    ERIC Educational Resources Information Center

    Nero, Shondel J.

    2014-01-01

    Using Jamaica, a former British colony where Jamaican Creole (JC) is the mass vernacular but Standard Jamaican English is the official language, as an illustrative case, this critical ethnographic study in three Jamaican schools examines the theoretical and practical challenges of language education policy (LEP) development and implementation in…

  15. Evaluating multicenter DTI data in Huntington's disease on site specific effects: An ex post facto approach.

    PubMed

    Müller, Hans-Peter; Grön, Georg; Sprengelmeyer, Reiner; Kassubek, Jan; Ludolph, Albert C; Hobbs, Nicola; Cole, James; Roos, Raymund A C; Duerr, Alexandra; Tabrizi, Sarah J; Landwehrmeyer, G Bernhard; Süssmuth, Sigurd D

    2013-01-01

    Assessment of the feasibility to average diffusion tensor imaging (DTI) metrics of MRI data acquired in the course of a multicenter study. Sixty-one early stage Huntington's disease patients and forty healthy controls were studied using four different MR scanners at four European sites with acquisition protocols as close as possible to a given standard protocol. The potential and feasibility of averaging data acquired at different sites was evaluated quantitatively by region-of-interest (ROI) based statistical comparisons of coefficients of variation (CV) across centers, as well as by testing for significant group-by-center differences on averaged fractional anisotropy (FA) values between patients and controls. In addition, a whole-brain based statistical between-group comparison was performed using FA maps. The ex post facto statistical evaluation of CV and FA-values in a priori defined ROIs showed no differences between sites above chance indicating that data were not systematically biased by center specific factors. Averaging FA-maps from DTI data acquired at different study sites and different MR scanner types does not appear to be systematically biased. A suitable recipe for testing on the possibility to pool multicenter DTI data is provided to permit averaging of DTI-derived metrics to differentiate patients from healthy controls at a larger scale.

  16. Evidence of dose saving in routine CT practice using iterative reconstruction derived from a national diagnostic reference level survey.

    PubMed

    Thomas, P; Hayton, A; Beveridge, T; Marks, P; Wallace, A

    2015-09-01

    To assess the influence and significance of the use of iterative reconstruction (IR) algorithms on patient dose in CT in Australia. We examined survey data submitted to the Australian Radiation Protection and Nuclear Safety Agency (ARPANSA) National Diagnostic Reference Level Service (NDRLS) during 2013 and 2014. We compared median survey dose metrics with categorization by scan region and use of IR. The use of IR results in a reduction in volume CT dose index of between 17% and 44% and a reduction in dose-length product of between 14% and 34% depending on the specific scan region. The reduction was highly significant (p < 0.001, Wilcoxon rank-sum test) for all six scan regions included in the NDRLS. Overall, 69% (806/1167) of surveys included in the analysis used IR. The use of IR in CT is achieving dose savings of 20-30% in routine practice in Australia. IR appears to be widely used by participants in the ARPANSA NDRLS with approximately 70% of surveys submitted employing this technique. This study examines the impact of the use of IR on patient dose in CT on a national scale.

  17. Real-Time Patient and Staff Radiation Dose Monitoring in IR Practice

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sailer, Anna M., E-mail: karmanna@stanford.edu; Paulis, Leonie, E-mail: leonie.paulis@mumc.nl; Vergoossen, Laura

    PurposeKnowledge of medical radiation exposure permits application of radiation protection principles. In our center, the first dedicated real-time, automated patient and staff dose monitoring system (DoseWise Portal, Philips Healthcare) was installed. Aim of this study was to obtain insight in the procedural and occupational doses.Materials and MethodsAll interventional radiologists, vascular surgeons, and technicians wore personal dose meters (PDMs, DoseAware, Philips Healthcare). The dose monitoring system simultaneously registered for each procedure dose-related data as the dose area product (DAP) and effective staff dose (E) from PDMs. Use and type of shielding were recorded separately. All procedures were analyzed according to proceduremore » type; these included among others cerebral interventions (n = 112), iliac and/or caval venous recanalization procedures (n = 68), endovascular aortic repair procedures (n = 63), biliary duct interventions (n = 58), and percutaneous gastrostomy procedure (n = 28).ResultsMedian (±IQR) DAP doses ranged from 2.0 (0.8–3.1) (percutaneous gastrostomy) to 84 (53–147) Gy cm{sup 2} (aortic repair procedures). Median (±IQR) first operator doses ranged from 1.6 (1.1–5.0) μSv to 33.4 (12.1–125.0) for these procedures, respectively. The relative exposure, determined as first operator dose normalized to procedural DAP, ranged from 1.9 in biliary interventions to 0.1 μSv/Gy cm{sup 2} in cerebral interventions, indicating large variation in staff dose per unit DAP among the procedure types.ConclusionReal-time dose monitoring was able to identify the types of interventions with either an absolute or relatively high staff dose, and may allow for specific optimization of radiation protection.« less

  18. Evaluating multicenter DTI data in Huntington's disease on site specific effects: An ex post facto approach☆

    PubMed Central

    Müller, Hans-Peter; Grön, Georg; Sprengelmeyer, Reiner; Kassubek, Jan; Ludolph, Albert C.; Hobbs, Nicola; Cole, James; Roos, Raymund A.C.; Duerr, Alexandra; Tabrizi, Sarah J.; Landwehrmeyer, G. Bernhard; Süssmuth, Sigurd D.

    2013-01-01

    Purpose Assessment of the feasibility to average diffusion tensor imaging (DTI) metrics of MRI data acquired in the course of a multicenter study. Materials and methods Sixty-one early stage Huntington's disease patients and forty healthy controls were studied using four different MR scanners at four European sites with acquisition protocols as close as possible to a given standard protocol. The potential and feasibility of averaging data acquired at different sites was evaluated quantitatively by region-of-interest (ROI) based statistical comparisons of coefficients of variation (CV) across centers, as well as by testing for significant group-by-center differences on averaged fractional anisotropy (FA) values between patients and controls. In addition, a whole-brain based statistical between-group comparison was performed using FA maps. Results The ex post facto statistical evaluation of CV and FA-values in a priori defined ROIs showed no differences between sites above chance indicating that data were not systematically biased by center specific factors. Conclusion Averaging FA-maps from DTI data acquired at different study sites and different MR scanner types does not appear to be systematically biased. A suitable recipe for testing on the possibility to pool multicenter DTI data is provided to permit averaging of DTI-derived metrics to differentiate patients from healthy controls at a larger scale. PMID:24179771

  19. Practical considerations in medical cannabis administration and dosing.

    PubMed

    MacCallum, Caroline A; Russo, Ethan B

    2018-03-01

    Cannabis has been employed medicinally throughout history, but its recent legal prohibition, biochemical complexity and variability, quality control issues, previous dearth of appropriately powered randomised controlled trials, and lack of pertinent education have conspired to leave clinicians in the dark as to how to advise patients pursuing such treatment. With the advent of pharmaceutical cannabis-based medicines (Sativex/nabiximols and Epidiolex), and liberalisation of access in certain nations, this ignorance of cannabis pharmacology and therapeutics has become untenable. In this article, the authors endeavour to present concise data on cannabis pharmacology related to tetrahydrocannabinol (THC), cannabidiol (CBD) et al., methods of administration (smoking, vaporisation, oral), and dosing recommendations. Adverse events of cannabis medicine pertain primarily to THC, whose total daily dose-equivalent should generally be limited to 30mg/day or less, preferably in conjunction with CBD, to avoid psychoactive sequelae and development of tolerance. CBD, in contrast to THC, is less potent, and may require much higher doses for its adjunctive benefits on pain, inflammation, and attenuation of THC-associated anxiety and tachycardia. Dose initiation should commence at modest levels, and titration of any cannabis preparation should be undertaken slowly over a period of as much as two weeks. Suggestions are offered on cannabis-drug interactions, patient monitoring, and standards of care, while special cases for cannabis therapeutics are addressed: epilepsy, cancer palliation and primary treatment, chronic pain, use in the elderly, Parkinson disease, paediatrics, with concomitant opioids, and in relation to driving and hazardous activities. Copyright © 2018 European Federation of Internal Medicine. Published by Elsevier B.V. All rights reserved.

  20. MO-F-304-01: Applying PDSA to a Practical Clinical Problem: Variation in Procedural Doses Among Interventional Radiologists

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jones, A.

    With the current Maintenance of Certification (MOC) requirement for a practice quality improvement (PQI) project every 3 years, we all (well, most of us) find ourselves searching for projects that are both manageable and likely to have a positive impact on our clinical practice. In this session we will walk through the use of the Plan, Do, Study, Act (PDSA) cycle to address a common finding in practices where fluoroscopically guided interventions (FGI) are performed: variation in procedural doses among physicians. We will also examine strategies to secure physician support using carrots, not sticks. Learning Objectives: Review the PDSA cyclemore » and its application to PQI. Discuss strategies for action in the example presented. Examine strategies for successful group PQI projects. A. Kyle Jones: Owner, FluoroSafety Joseph R. Steele: Consultant, FluoroSafety.« less

  1. OVERVIEW, PRACTICAL TIPS AND POTENTIAL PITFALLS OF USING AUTOMATIC EXPOSURE CONTROL IN CT: SIEMENS CARE DOSE 4D.

    PubMed

    Söderberg, Marcus

    2016-06-01

    Today, computed tomography (CT) systems routinely use automatic exposure control (AEC), which modulates the tube current. However, for optimal use, there are several aspects of an AEC system that need to be considered. The purpose of this study was to provide an overview of the Siemens CARE Dose 4D AEC system, discuss practical tips and demonstrate potential pitfalls. Two adult anthropomorphic phantoms were examined using two different Siemens CT systems. When optimising the CT radiation dose and image quality, the projection angle of the localiser, patient centring, protocol selection, scanning direction and the use of protective devices requires special attention. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  2. Patient doses from chest radiography in Victoria.

    PubMed

    Cardillo, I; Boal, T J; Einsiedel, P F

    1997-06-01

    This survey examines doses from PA chest radiography at radiology practices, private hospitals and public hospitals throughout metropolitan and country Victoria. Data were collected from 111 individual X-ray units at 86 different practices. Entrance skin doses in air were measured for exposure factors used by the centre for a 23 cm thick male chest. A CDRH LucA1 chest phantom was used when making these measurements. About half of the centres used grid technique and half used non-grid technique. There was a factor of greater than 10 difference in the entrance dose delivered between the highest dose centre and the lowest dose centre for non-grid centres; and a factor of about 5 for centres using grids. Factors contributing to the high doses recorded at some centres were identified. Guidance levels for chest radiography based on the third quartile value of the entrance doses from this survey have been recommended and compared with guidance levels recommended in other countries.

  3. SIMPLIFIED PRACTICAL TEST METHOD FOR PORTABLE DOSE METERS USING SEVERAL SEALED RADIOACTIVE SOURCES.

    PubMed

    Mikamoto, Takahiro; Yamada, Takahiro; Kurosawa, Tadahiro

    2016-09-01

    Sealed radioactive sources which have small activity were employed for the determination of response and tests for non-linearity and energy dependence of detector responses. Close source-to-detector geometry (at 0.3 m or less) was employed to practical tests for portable dose meters to accumulate statistically sufficient ionizing currents. Difference between response in the present experimentally studied field and in the reference field complied with ISO 4037 due to non-uniformity of radiation fluence at close geometry was corrected by use of Monte Carlo simulation. As a consequence, corrected results were consistent with the results obtained in the ISO 4037 reference field within their uncertainties. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  4. Dose gradient curve: A new tool for evaluating dose gradient.

    PubMed

    Sung, KiHoon; Choi, Young Eun

    2018-01-01

    Stereotactic radiotherapy, which delivers an ablative high radiation dose to a target volume for maximum local tumor control, requires a rapid dose fall-off outside the target volume to prevent extensive damage to nearby normal tissue. Currently, there is no tool to comprehensively evaluate the dose gradient near the target volume. We propose the dose gradient curve (DGC) as a new tool to evaluate the quality of a treatment plan with respect to the dose fall-off characteristics. The average distance between two isodose surfaces was represented by the dose gradient index (DGI) estimated by a simple equation using the volume and surface area of isodose levels. The surface area was calculated by mesh generation and surface triangulation. The DGC was defined as a plot of the DGI of each dose interval as a function of the dose. Two types of DGCs, differential and cumulative, were generated. The performance of the DGC was evaluated using stereotactic radiosurgery plans for virtual targets. Over the range of dose distributions, the dose gradient of each dose interval was well-characterized by the DGC in an easily understandable graph format. Significant changes in the DGC were observed reflecting the differences in planning situations and various prescription doses. The DGC is a rational method for visualizing the dose gradient as the average distance between two isodose surfaces; the shorter the distance, the steeper the dose gradient. By combining the DGC with the dose-volume histogram (DVH) in a single plot, the DGC can be utilized to evaluate not only the dose gradient but also the target coverage in routine clinical practice.

  5. Dose gradient curve: A new tool for evaluating dose gradient

    PubMed Central

    Choi, Young Eun

    2018-01-01

    Purpose Stereotactic radiotherapy, which delivers an ablative high radiation dose to a target volume for maximum local tumor control, requires a rapid dose fall-off outside the target volume to prevent extensive damage to nearby normal tissue. Currently, there is no tool to comprehensively evaluate the dose gradient near the target volume. We propose the dose gradient curve (DGC) as a new tool to evaluate the quality of a treatment plan with respect to the dose fall-off characteristics. Methods The average distance between two isodose surfaces was represented by the dose gradient index (DGI) estimated by a simple equation using the volume and surface area of isodose levels. The surface area was calculated by mesh generation and surface triangulation. The DGC was defined as a plot of the DGI of each dose interval as a function of the dose. Two types of DGCs, differential and cumulative, were generated. The performance of the DGC was evaluated using stereotactic radiosurgery plans for virtual targets. Results Over the range of dose distributions, the dose gradient of each dose interval was well-characterized by the DGC in an easily understandable graph format. Significant changes in the DGC were observed reflecting the differences in planning situations and various prescription doses. Conclusions The DGC is a rational method for visualizing the dose gradient as the average distance between two isodose surfaces; the shorter the distance, the steeper the dose gradient. By combining the DGC with the dose-volume histogram (DVH) in a single plot, the DGC can be utilized to evaluate not only the dose gradient but also the target coverage in routine clinical practice. PMID:29698471

  6. Defining unnecessary disinfection procedures for single-dose and multiple-dose vials.

    PubMed

    Buckley, T; Dudley, S M; Donowitz, L G

    1994-11-01

    Recommendations in the literature conflict on the necessity of disinfecting single-use vials prior to aspiration of fluid. Interventions to disinfect the stopper surface on multiple-dose vials vary considerably. To determine the necessity of alcohol disinfection of the stopper on single-dose vials and to compare povidone-iodine and alcohol versus alcohol-only disinfection of the stopper prior to each needle penetration on multiple-dose vials. The rubber stopper surfaces of 100 single-dose vials were cultured for the presence of bacteria. To determine the efficacy of two procedures for disinfection of multiple-dose vials, 87 stopper surfaces routinely disinfected with both povidone-iodine and alcohol were cultured for bacteria. After a change in practice, 100 multiple-dose vials routinely disinfected with alcohol only were cultured for the presence of bacteria. Of the cultures done on single-dose vial stoppers, 99% were sterile. A comparison of the two disinfection techniques for multiple-dose vials revealed that 83 (95%) of the 87 vials prepped with both povidone-iodine and alcohol were sterile, compared with all stoppers disinfected with alcohol only. This study shows the lack of necessity of any disinfection procedure on the rubber stopper of single-dose vials and the efficacy of alcohol only for disinfecting the stopper of multiple-dose vials.

  7. Antimicrobial prescribing practice in UK equine veterinary practice.

    PubMed

    Hughes, L A; Pinchbeck, G; Callaby, R; Dawson, S; Clegg, P; Williams, N

    2013-03-01

    Antimicrobial use is known to select for the emergence of resistant strains of bacteria; therefore prudent use in both human and veterinary medicine is essential to preserve their efficacy. To characterise antimicrobial prescribing patterns in UK equine practice and evaluate factors associated with prescribing. A postal questionnaire including 4 clinical scenarios was sent to 740 veterinary surgeons that treat horses. Data were collected on the clinician, their practice and sources of information regarding antimicrobials and their use. Multivariable logistic regression analysis was used to ascertain factors associated with 5 outcomes; prescribing off-licence drugs; prescribing at incorrect doses; prescribing 3rd or 4th generation cephalosporins; prescribing fluoroquinolones and prescribing potentiated sulphonamides. Questionnaires were completed by 38% of veterinary surgeons who were sent questionnaires. Less than 1% of practices had antimicrobial use guidelines. Trimethoprim-sulphonamides were most commonly prescribed in each clinical scenario. Eleven percent of prescriptions were for antimicrobial drugs not licensed for use in horses in the UK. Five percent of prescriptions for licensed antimicrobials were under the recommended dose rate and 56% over the recommended dose rate. Fluoroquinolones and 3rd and 4th generation cephalosporins accounted for 1 and 3% of prescriptions, respectively. Veterinary surgeons working at referral practices were more likely to prescribe 3rd and 4th generation cephalosporins and fluoroquinolones and off-licence antimicrobials whereas those working in first-opinion practices were more likely to prescribe potentiated sulphonamides. Sources of information regarding antimicrobials also had an effect on prescribing. Prescription of antimicrobials at inappropriate doses was common even when provided with the weight of the animal. It is uncommon for UK equine veterinary practices to have guidelines for antimicrobial use. The introduction of

  8. Identifying the most successful dose (MSD) in dose-finding studies in cancer.

    PubMed

    Zohar, Sarah; O'Quigley, John

    2006-01-01

    For a dose finding study in cancer, the most successful dose (MSD), among a group of available doses, is that dose at which the overall success rate is the highest. This rate is the product of the rate of seeing non-toxicities together with the rate of tumor response. A successful dose finding trial in this context is one where we manage to identify the MSD in an efficient manner. In practice we may also need to consider algorithms for identifying the MSD which can incorporate certain restrictions, the most common restriction maintaining the estimated toxicity rate alone below some maximum rate. In this case the MSD may correspond to a different level than that for the unconstrained MSD and, in providing a final recommendation, it is important to underline that it is subject to the given constraint. We work with the approach described in O'Quigley et al. [Biometrics 2001; 57(4):1018-1029]. The focus of that work was dose finding in HIV where both information on toxicity and efficacy were almost immediately available. Recent cancer studies are beginning to fall under this same heading where, as before, toxicity can be quickly evaluated and, in addition, we can rely on biological markers or other measures of tumor response. Mindful of the particular context of cancer, our purpose here is to consider the methodology developed by O'Quigley et al. and its practical implementation. We also carry out a study on the doubly under-parameterized model, developed by O'Quigley et al. but not

  9. Best Practices in Stability Indicating Method Development and Validation for Non-clinical Dose Formulations.

    PubMed

    Henry, Teresa R; Penn, Lara D; Conerty, Jason R; Wright, Francesca E; Gorman, Gregory; Pack, Brian W

    2016-11-01

    Non-clinical dose formulations (also known as pre-clinical or GLP formulations) play a key role in early drug development. These formulations are used to introduce active pharmaceutical ingredients (APIs) into test organisms for both pharmacokinetic and toxicological studies. Since these studies are ultimately used to support dose and safety ranges in human studies, it is important to understand not only the concentration and PK/PD of the active ingredient but also to generate safety data for likely process impurities and degradation products of the active ingredient. As such, many in the industry have chosen to develop and validate methods which can accurately detect and quantify the active ingredient along with impurities and degradation products. Such methods often provide trendable results which are predictive of stability, thus leading to the name; stability indicating methods. This document provides an overview of best practices for those choosing to include development and validation of such methods as part of their non-clinical drug development program. This document is intended to support teams who are either new to stability indicating method development and validation or who are less familiar with the requirements of validation due to their position within the product development life cycle.

  10. SCCT guidelines on radiation dose and dose-optimization strategies in cardiovascular CT

    PubMed Central

    Halliburton, Sandra S.; Abbara, Suhny; Chen, Marcus Y.; Gentry, Ralph; Mahesh, Mahadevappa; Raff, Gilbert L.; Shaw, Leslee J.; Hausleiter, Jörg

    2012-01-01

    Over the last few years, computed tomography (CT) has developed into a standard clinical test for a variety of cardiovascular conditions. The emergence of cardiovascular CT during a period of dramatic increase in radiation exposure to the population from medical procedures and heightened concern about the subsequent potential cancer risk has led to intense scrutiny of the radiation burden of this new technique. This has hastened the development and implementation of dose reduction tools and prompted closer monitoring of patient dose. In an effort to aid the cardiovascular CT community in incorporating patient-centered radiation dose optimization and monitoring strategies into standard practice, the Society of Cardiovascular Computed Tomography has produced a guideline document to review available data and provide recommendations regarding interpretation of radiation dose indices and predictors of risk, appropriate use of scanner acquisition modes and settings, development of algorithms for dose optimization, and establishment of procedures for dose monitoring. PMID:21723512

  11. Pediatric First Aid Practices in Ghana: A Population-Based Survey.

    PubMed

    Gyedu, Adam; Mock, Charles; Nakua, Emmanuel; Otupiri, Easmon; Donkor, Peter; Ebel, Beth E

    2015-08-01

    Children in low- and middle-income countries (LMIC) often receive care outside the formal medical sector. Improving pre-hospital first aid has proven to be highly cost-effective in lowering trauma mortality. Few studies in LMIC have examined home first aid practices for injured children. We conducted a representative population-based survey of 200 caregivers of children under 18 years of age, representing 6520 households. Caregivers were interviewed about their first aid practices and care-seeking behaviors when a child sustained an injury at home. Injuries of interest included burns, lacerations, fractures and choking. Reported practices were characterized as recommended, low-risk, and potentially harmful. For common injuries, 75-96% of caregivers reported employing a recommended practice (e.g., running cool water over a burn injury). However, for these same injuries, 13-61% of caregivers also identified potentially harmful management strategies (e.g., applying sand to a laceration). Choking had the highest proportion (96%) of recommended first aid practice: (e.g., hitting the child's back) and the lowest percent (13%) of potentially harmful practices (e.g., attempting manual removal). Fractures had the lowest percent (75%) of recommended practices (e.g., immediately bringing the child to a health facility). Burns had the highest percent (61%) of potentially harmful practices (e.g., applying kerosene). While most caregivers were aware of helpful first aid practices to administer for a child injury, many parents also described potentially harmful practices or delays in seeking medical attention. As parents are the de facto first responders to childhood injury, there are opportunities to strengthen pre-hospital care for children in LMICs.

  12. Ex post facto assessment of diffusion tensor imaging metrics from different MRI protocols: preparing for multicentre studies in ALS.

    PubMed

    Rosskopf, Johannes; Müller, Hans-Peter; Dreyhaupt, Jens; Gorges, Martin; Ludolph, Albert C; Kassubek, Jan

    2015-03-01

    Diffusion tensor imaging (DTI) for assessing ALS-associated white matter alterations has still not reached the level of a neuroimaging biomarker. Since large-scale multicentre DTI studies in ALS may be hampered by differences in scanning protocols, an approach for pooling of DTI data acquired with different protocols was investigated. Three hundred and nine datasets from 170 ALS patients and 139 controls were collected ex post facto from a monocentric database reflecting different scanning protocols. A 3D correction algorithm was introduced for a combined analysis of DTI metrics despite different acquisition protocols, with the focus on the CST as the tract correlate of ALS neuropathological stage 1. A homogenous set of data was obtained by application of 3D correction matrices. Results showed that a fractional anisotropy (FA) threshold of 0.41 could be defined to discriminate ALS patients from controls (sensitivity/specificity, 74%/72%). For the remaining test sample, sensitivity/specificity values of 68%/74% were obtained. In conclusion, the objective was to merge data recorded with different DTI protocols with 3D correction matrices for analyses at group level. These post processing tools might facilitate analysis of large study samples in a multicentre setting for DTI analysis at group level to aid in establishing DTI as a non-invasive biomarker for ALS.

  13. Vancomycin Dosing in Obese Patients: Special Considerations and Novel Dosing Strategies.

    PubMed

    Durand, Cheryl; Bylo, Mary; Howard, Brian; Belliveau, Paul

    2018-06-01

    To review the literature regarding vancomycin pharmacokinetics in obese patients and strategies used to improve dosing in this population. PubMed, EMBASE (1974 to November 2017), and Google Scholar searches were conducted using the search terms vancomycin, obese, obesity, pharmacokinetics, strategy, and dosing. Additional articles were selected from reference lists of selected studies. Included articles were those published in English with a primary focus on vancomycin pharmacokinetic parameters in obese patients and practical vancomycin dosing strategies, clinical experiences, or challenges of dosing vancomycin in this population. Volume of distribution and clearance are the pharmacokinetic parameters that most often affect vancomycin dosing in obese patients; both are increased in this population. Challenges with dosing in obese patients include inconsistent and inadequate dosing, observations that the obese population may not be homogeneous, and reports of an increased likelihood of supratherapeutic trough concentrations. Investigators have revised and developed dosing and monitoring protocols to address these challenges. These approaches improved target trough attainment to varying degrees. Some of the vancomycin dosing approaches provided promising results in obese patients, but there were notable differences in methods used to develop these approaches, and sample sizes were small. Although some approaches can be considered for validation in individual institutions, further research is warranted. This may include validating approaches in larger populations with narrower obesity severity ranges, investigating target attainment in indication-specific target ranges, and evaluating the impact of different dosing weights and methods of creatinine clearance calculation.

  14. Analysis of international content of ranked nursing journals in 2005 using ex post facto design.

    PubMed

    Dougherty, Molly C; Lin, Shu-Yuan; McKenna, Hugh P; Seers, Kate; Keeney, Sinead

    2011-06-01

    The purpose of this study was to examine articles in ISI-ranked nursing journals and to analyse the articles and journals, using definitions of international and article content. Growing emphasis on global health includes attention on international nursing literature. Contributions from Latin America and Africa have been reported. Attention to ranked nursing journals to support scholarship in global health is needed. Using an ex post facto design, characteristics of 2827 articles, authors and journals of 32 ranked nursing journals for the year 2005 were analysed between June 2006 and June 2007. Using definitions of international and of article content, research questions were analysed statistically. (a) 928 (32·8%) articles were international; (b) 2016 (71·3%) articles were empirical or scholarly; (c) 826 (89·3%) articles reflecting international content were scholarly or empirical; (d) among international articles more were empirical (66·3 % vs. 32·8 %; χ(2) ((1)) = 283·6, P < 0·001); (e) among non-international articles more were scholarly (29·2 % vs. 22·7 %; χ(2) ((1)) = 15·85, P < 0·001; 22·7 %); (f) 1004 (78·0 %) articles were international, based on author characteristics; (f) 20 (62·5 %) journals were led by an international editorial team; and (g) international journals had more international articles (3·6 % vs. 29·2 %; χ(2) ((1)) = 175·75, P < 0·001) and higher impact factors than non-international journals (t = -14·43, P < 0·001). Articles with empirical content appear more frequently in international journals. Results indicate the need to examine the international relevance of the nursing literature. © 2011 Blackwell Publishing Ltd.

  15. Student's music exposure: Full-day personal dose measurements.

    PubMed

    Washnik, Nilesh Jeevandas; Phillips, Susan L; Teglas, Sandra

    2016-01-01

    Previous studies have shown that collegiate level music students are exposed to potentially hazardous sound levels. Compared to professional musicians, collegiate level music students typically do not perform as frequently, but they are exposed to intense sounds during practice and rehearsal sessions. The purpose of the study was to determine the full-day exposure dose including individual practice and ensemble rehearsals for collegiate student musicians. Sixty-seven college students of classical music were recruited representing 17 primary instruments. Of these students, 57 completed 2 days of noise dose measurements using Cirrus doseBadge programed according to the National Institute for Occupational Safety and Health criterion. Sound exposure was measured for 2 days from morning to evening, ranging from 7 to 9 h. Twenty-eight out of 57 (49%) student musicians exceeded a 100% daily noise dose on at least 1 day of the two measurement days. Eleven student musicians (19%) exceeded 100% daily noise dose on both days. Fourteen students exceeded 100% dose during large ensemble rehearsals and eight students exceeded 100% dose during individual practice sessions. Approximately, half of the student musicians exceeded 100% noise dose on a typical college schedule. This finding indicates that a large proportion of collegiate student musicians are at risk of developing noise-induced hearing loss due to hazardous sound levels. Considering the current finding, there is a need to conduct hearing conservation programs in all music schools, and to educate student musicians about the use and importance of hearing protection devices for their hearing.

  16. Student's music exposure: Full-day personal dose measurements

    PubMed Central

    Washnik, Nilesh Jeevandas; Phillips, Susan L.; Teglas, Sandra

    2016-01-01

    Previous studies have shown that collegiate level music students are exposed to potentially hazardous sound levels. Compared to professional musicians, collegiate level music students typically do not perform as frequently, but they are exposed to intense sounds during practice and rehearsal sessions. The purpose of the study was to determine the full-day exposure dose including individual practice and ensemble rehearsals for collegiate student musicians. Sixty-seven college students of classical music were recruited representing 17 primary instruments. Of these students, 57 completed 2 days of noise dose measurements using Cirrus doseBadge programed according to the National Institute for Occupational Safety and Health criterion. Sound exposure was measured for 2 days from morning to evening, ranging from 7 to 9 h. Twenty-eight out of 57 (49%) student musicians exceeded a 100% daily noise dose on at least 1 day of the two measurement days. Eleven student musicians (19%) exceeded 100% daily noise dose on both days. Fourteen students exceeded 100% dose during large ensemble rehearsals and eight students exceeded 100% dose during individual practice sessions. Approximately, half of the student musicians exceeded 100% noise dose on a typical college schedule. This finding indicates that a large proportion of collegiate student musicians are at risk of developing noise-induced hearing loss due to hazardous sound levels. Considering the current finding, there is a need to conduct hearing conservation programs in all music schools, and to educate student musicians about the use and importance of hearing protection devices for their hearing. PMID:26960787

  17. Simultaneously optimizing dose and schedule of a new cytotoxic agent.

    PubMed

    Braun, Thomas M; Thall, Peter F; Nguyen, Hoang; de Lima, Marcos

    2007-01-01

    Traditionally, phase I clinical trial designs are based upon one predefined course of treatment while varying among patients the dose given at each administration. In actual medical practice, patients receive a schedule comprised of several courses of treatment, and some patients may receive one or more dose reductions or delays during treatment. Consequently, the overall risk of toxicity for each patient is a function of both actual schedule of treatment and the differing doses used at each adminstration. Our goal is to provide a practical phase I clinical trial design that more accurately reflects actual medical practice by accounting for both dose per administration and schedule. We propose an outcome-adaptive Bayesian design that simultaneously optimizes both dose and schedule in terms of the overall risk of toxicity, based on time-to-toxicity outcomes. We use computer simulation as a tool to calibrate design parameters. We describe a phase I trial in allogeneic bone marrow transplantation that was designed and is currently being conducted using our new method. Our computer simulations demonstrate that our method outperforms any method that searches for an optimal dose but does not allow schedule to vary, both in terms of the probability of identifying optimal (dose, schedule) combinations, and the numbers of patients assigned to those combinations in the trial. Our design requires greater sample sizes than those seen in traditional phase I studies due to the larger number of treatment combinations examined. Our design also assumes that the effects of multiple administrations are independent of each other and that the hazard of toxicity is the same for all administrations. Our design is the first for phase I clinical trials that is sufficiently flexible and practical to truly reflect clinical practice by varying both dose and the timing and number of administrations given to each patient.

  18. Human papillomavirus vaccination coverage using two-dose or three-dose schedule criteria.

    PubMed

    Lin, Xia; Rodgers, Loren; Zhu, Liping; Stokley, Shannon; Meites, Elissa; Markowitz, Lauri E

    2017-10-13

    In October 2016, the Advisory Committee on Immunization Practices (ACIP) updated the human papillomavirus (HPV) vaccination recommendation to include a 2-dose schedule for U.S. adolescents initiating the vaccine series before their 15th birthday. We analyzed records for >4million persons aged 9-17years receiving any HPV vaccine by the end of each quarter during January 1, 2014-September 30, 2016 from six Immunization Information Systems Sentinel Sites, and reclassified HPV vaccination up-to-date coverage according to the updated recommendations. Compared with HPV vaccination up-to-date coverage by the 3-dose schedule only, including criteria for either a 2-dose or 3-dose schedule increased up-to-date coverage in 11-12, 13-14, and 15-17 year-olds by 4.5-8.5 percentage points. The difference between 3-dose up-to-date coverage and 2- or 3-dose up-to-date coverage was greatest in late 2016. These data provide baseline HPV vaccination coverage using current ACIP recommendations. Published by Elsevier Ltd.

  19. A correlation study of eye lens dose and personal dose equivalent for interventional cardiologists.

    PubMed

    Farah, J; Struelens, L; Dabin, J; Koukorava, C; Donadille, L; Jacob, S; Schnelzer, M; Auvinen, A; Vanhavere, F; Clairand, I

    2013-12-01

    This paper presents the dosimetry part of the European ELDO project, funded by the DoReMi Network of Excellence, in which a method was developed to estimate cumulative eye lens doses for past practices based on personal dose equivalent values, H(p)(10), measured above the lead apron at several positions at the collar, chest and waist levels. Measurement campaigns on anthropomorphic phantoms were carried out in typical interventional settings considering different tube projections and configurations, beam energies and filtration, operator positions and access routes and using both mono-tube and biplane X-ray systems. Measurements showed that eye lens dose correlates best with H(p)(10) measured on the left side of the phantom at the level of the collar, although this correlation implicates high spreads (41 %). Nonetheless, for retrospective dose assessment, H(p)(10) records are often the only option for eye dose estimates and the typically used chest left whole-body dose measurement remains useful.

  20. Practical simplifications for radioimmunotherapy dosimetric models

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shen, S.; DeNardo, G.L.; O`Donnell, R.T.

    1999-01-01

    Radiation dosimetry is potentially useful for assessment and prediction of efficacy and toxicity for radionuclide therapy. The usefulness of these dose estimates relies on the establishment of a dose-response model using accurate pharmacokinetic data and a radiation dosimetric model. Due to the complexity in radiation dose estimation, many practical simplifications have been introduced in the dosimetric modeling for clinical trials of radioimmunotherapy. Although research efforts are generally needed to improve the simplifications used at each stage of model development, practical simplifications are often possible for specific applications without significant consequences to the dose-response model. In the development of dosimetric methodsmore » for radioimmunotherapy, practical simplifications in the dosimetric models were introduced. This study evaluated the magnitude of uncertainty associated with practical simplifications for: (1) organ mass of the MIRD phantom; (2) radiation contribution from target alone; (3) interpolation of S value; (4) macroscopic tumor uniformity; and (5) fit of tumor pharmacokinetic data.« less

  1. Effect of streptokinase on reperfusion after acute myocardial infarction and its complications: an ex-post facto study.

    PubMed

    Taheri, Leila; Boroujeni, Ali Zargham; Kargar Jahromi, Marzieh; Charkhandaz, Maryam; Hojat, Mohsen

    2015-01-01

    Emergency treatment of patients with acute myocardial infarction is very important. Streptokinase in Iran is often as the only clot-busting medication is used. The purpose of using streptokinase medication is to revive the ischemic heart tissue, although has dangerous complications too. Therefore, the present study aimed to determine the effect of streptokinase on reperfusion after acute myocardial infarction and its complications, has been designed and conducted. This is an Ex-post facto study. The study population included patients who suffer from acute myocardial infarction. The sample size was 300 patients, and 2 groups were matched, in variables of age, sex, underlying disease, frequencies and area of MI. Data collection did by researcher making questionnaire, that accept face and content validity by 10 expert researcher, the reliability was conducted with Spearman's test (r=0.85) by Test-retest method. Data analysis did by SPSS software: V 12. Mean of EF in SK group was (46.15±8.11) and in control group was (43.11±12.57). Significant relationship was seen between SK, arrhythmia occurring and improve EF reperfusion by chi-square test (p=0.028), (p=0.020).The most arrhythmia in SK group was Ventricular Tachycardia (20.7%). Significant statistical relation between SK and mortality were found by Chi-square test (p=0.001). But a meaningful statistical relation was not found between SK and pulmonary edema incidence (p=0.071). Nurses of CCU should be aware about SK complications such as hypotension, bleeding and arrhythmias. Proposed compare SK and tissue plasminogen drug in reperfusion and complications effect.

  2. De facto Privatization and Inequalities in Educational Opportunity in the Transition to Secondary School in Rural Malawi.

    PubMed

    Grant, Monica J

    2017-09-01

    There has been a recent, rapid de facto privatization of education in many African countries, as the number of private secondary schools operating in the region grew. The majority of these schools are "low-cost" private schools where tuition and fees are set as low as possible to cover operating costs and still generate profit. Proponents of low-cost private schools argue that these schools have proliferated in impoverished areas to meet unmet demand for access to education and where private schools may offer better quality than locally available public schools. Theories of inequality of educational opportunity suggest that if private schools offer better quality education, students from more advantaged families will be more likely to enroll at these institutions, potentially exacerbating educational inequality in the region. This analysis uses data from a school-based longitudinal survey, the Malawi Schooling and Adolescent Study, to examine socio-economic inequalities in the transition to secondary school and on-time enrollment in upper secondary. My findings indicate that youth from non-poor households are not only more likely to enroll in secondary school than poor youth, but they are also more likely to substitute enrollment in private schools for enrollment in second-tier government schools. Enrollment at private schools, however, does not yield schooling advantages; relative to both tiers of government secondary schooling, students who initially enrolled at private schools were the least likely to enroll on time in upper secondary school. These patterns suggest that these schooling circumstances may yield less segregation of opportunity than might otherwise be assumed.

  3. Intraoral radiology in general dental practices - a comparison of digital and film-based X-ray systems with regard to radiation protection and dose reduction.

    PubMed

    Anissi, H D; Geibel, M A

    2014-08-01

    The purpose of this study was to gain insight into the distribution and application of digital intraoral radiographic techniques within general dental practices and to compare these with film-based systems in terms of patient dose reduction. 1100 questionnaires were handed out to general dental practitioners. Data was analyzed with respect to the type of system by using descriptive statistics and nonparametric tests, i.e. Kruskal-Wallis, Mann-Whitney and chi-square test (SPSS 20). 64% of the questioned dentists still use film-based radiology, 23% utilize storage phosphor plate (SPP) systems and 13% use a charge-coupled device (CCD). A strong correlation between the number of dentists working in a practice and the use of digital dental imaging was observed. Almost 3/4 of the film users work with E- or F-speed film. 45% of them refuse to change to a digital system. The use of lead aprons was popular, while only a minority preferred thyroid shields and rectangular collimators. A fourfold reduction of exposure time from D-speed film to CCD systems was observed. Due to detector size and positioning errors, users of CCD systems take significantly more single-tooth radiographs in total. Considering the number of radiographs per patient, there is only a slight tendency towards more X-rays with CCD systems. Up to image generation, digital systems seem to be as or even more difficult to handle than film-based systems, while their handling was favored after radiographic exposure. Despite a slight increase of radiographs taken with CCD systems, there is a significant dosage reduction. Corresponding to the decrease in exposure time, the patient dose for SPP systems is reduced to one half compared to film. The main issues in CCD technology are positioning errors and the size of the X-ray detectors which are difficult to eliminate. The usage of radiation protection measures still needs to be improved. ► Responsible use of digital intraoral radiology results in a significant

  4. SU-F-T-06: Development of a Formalism for Practical Dose Measurements in Brachytherapy in the German Standard DIN 6803

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hensley, F; Chofor, N; Schoenfeld, A

    2016-06-15

    Purpose: In the steep dose gradients in the vicinity of a radiation source and due to the properties of the changing photon spectra, dose measurements in Brachytherapy usually have large uncertainties. Working group DIN 6803-3 is presently discussing recommendations for practical brachytherapy dosimetry incorporating recent theoretical developments in the description of brachytherapy radiation fields as well as new detectors and phantom materials. The goal is to prepare methods and instruments to verify dose calculation algorithms and for clinical dose verification with reduced uncertainties. Methods: After analysis of the distance dependent spectral changes of the radiation field surrounding brachytherapy sources, themore » energy dependent response of typical brachytherapy detectors was examined with Monte Carlo simulations. A dosimetric formalism was developed allowing the correction of their energy dependence as function of source distance for a Co-60 calibrated detector. Water equivalent phantom materials were examined with Monte Carlo calculations for their influence on brachytherapy photon spectra and for their water equivalence in terms of generating equivalent distributions of photon spectra and absorbed dose to water. Results: The energy dependence of a detector in the vicinity of a brachytherapy source can be described by defining an energy correction factor kQ for brachytherapy in the same manner as in existing dosimetry protocols which incorporates volume averaging and radiation field distortion by the detector. Solid phantom materials were identified which allow precise positioning of a detector together with small correctable deviations from absorbed dose to water. Recommendations for the selection of detectors and phantom materials are being developed for different measurements in brachytherapy. Conclusion: The introduction of kQ for brachytherapy sources may allow more systematic and comparable dose measurements. In principle, the corrections can

  5. Clinical decision-making tools for exam selection, reporting and dose tracking.

    PubMed

    Brink, James A

    2014-10-01

    Although many efforts have been made to reduce the radiation dose associated with individual medical imaging examinations to "as low as reasonably achievable," efforts to ensure such examinations are performed only when medically indicated and appropriate are equally if not more important. Variations in the use of ionizing radiation for medical imaging are concerning, regardless of whether they occur on a local, regional or national basis. Such variations among practices can be reduced with the use of decision support tools at the time of order entry. These tools help reduce radiation exposure among practices through the appropriate use of medical imaging. Similarly, adoption of best practices among imaging facilities can be promoted through tracking the radiation exposure among imaging patients. Practices can benchmark their aggregate radiation exposures for medical imaging through the use of dose index registries. However several variables must be considered when contemplating individual patient dose tracking. The specific dose measures and the variation among them introduced by variations in body habitus must be understood. Moreover the uncertainties in risk estimation from dose metrics related to age, gender and life expectancy must also be taken into account.

  6. Defect evolution in a Nisbnd Mosbnd Crsbnd Fe alloy subjected to high-dose Kr ion irradiation at elevated temperature

    NASA Astrophysics Data System (ADS)

    de los Reyes, Massey; Voskoboinikov, Roman; Kirk, Marquis A.; Huang, Hefei; Lumpkin, Greg; Bhattacharyya, Dhriti

    2016-06-01

    A candidate Nisbnd Mosbnd Crsbnd Fe alloy (GH3535) for application as a structural material in a molten salt nuclear reactor was irradiated with 1 MeV Kr2+ ions (723 K, max dose of 100 dpa) at the IVEM-Tandem facility. The evolution of defects like dislocation loops and vacancy- and self-interstitial clusters was examined in-situ. For obtaining a deeper insight into the true nature of these defects, the irradiated sample was further analysed under a TEM post-facto. The results show that there is a range of different types of defects formed under irradiation. Interaction of radiation defects with each other and with pre-existing defects, e.g., linear dislocations, leads to the formation of complex microstructures. Molecular dynamics simulations used to obtain a greater understanding of these defect transformations showed that the interaction between linear dislocations and radiation induced dislocation loops could form faulted structures that explain the fringed contrast of these defects observed in TEM.

  7. Radon Exposure and the Definition of Low Doses-The Problem of Spatial Dose Distribution.

    PubMed

    Madas, Balázs G

    2016-07-01

    Investigating the health effects of low doses of ionizing radiation is considered to be one of the most important fields in radiological protection research. Although the definition of low dose given by a dose range seems to be clear, it leaves some open questions. For example, the time frame and the target volume in which absorbed dose is measured have to be defined. While dose rate is considered in the current system of radiological protection, the same cancer risk is associated with all exposures, resulting in a given amount of energy absorbed by a single target cell or distributed among all the target cells of a given organ. However, the biological effects and so the health consequences of these extreme exposure scenarios are unlikely to be the same. Due to the heterogeneous deposition of radon progeny within the lungs, heterogeneous radiation exposure becomes a practical issue in radiological protection. While the macroscopic dose is still within the low dose range, local tissue doses on the order of Grays can be reached in the most exposed parts of the bronchial airways. It can be concluded that progress in low dose research needs not only low dose but also high dose experiments where small parts of a biological sample receive doses on the order of Grays, while the average dose over the whole sample remains low. A narrow interpretation of low dose research might exclude investigations with high relevance to radiological protection. Therefore, studies important to radiological protection should be performed in the frame of low dose research even if the applied doses do not fit in the dose range used for the definition of low doses.

  8. Initial apixaban dosing in patients with atrial fibrillation.

    PubMed

    Buchholz, Alexander; Ueberham, Laura; Gorczynska, Kaja; Dinov, Borislav; Hilbert, Sebastian; Dagres, Nikolaos; Husser, Daniela; Hindricks, Gerhard; Bollmann, Andreas

    2018-05-01

    Apixaban is a non-vitamin K oral anticoagulant approved for prevention of stroke and systemic embolism in patients with nonvalvular atrial fibrillation (AF). Current labeling recommends dose reduction based on patient age, weight, and renal function. The aim of this study was to analyze adherence to current labeling instructions concerning initial apixaban dosing in clinical practice and identify factors associated with inappropriate dose reduction. Patients with AF initiated on apixaban in 2016 were identified in the Heart Center Leipzig database. Records were screened to identify patient characteristics, prescribed apixaban dose, renal function, and further dosing-relevant secondary diagnoses and co-medication. We identified 569 consecutive patients with AF initiated on apixaban. In 301 (52.9%) patients, apixaban was prescribed in standard dose (5 mg b.i.d.) and in 268 (47.1%) in a reduced dose (2.5 mg b.i.d.). Of 268 patients receiving a reduced dose, 163 (60.8%) did not meet labeling criteria for dose reduction. In univariate and multivariate regression analysis, age (OR: 0.736, 95% CI: 0.664-0.816, P < 0.0001), patient weight (OR: 1.120, 95% CI: 1.076-1.166, P < 0.0001), and serum creatinine level (OR: 0.910, 95% CI: 0.881-0.940, P < 0.0001) were independent predictors for apixaban underdosage. In clinical practice, apixaban dosing is frequently inconsistent with labeling. Factors associated with inappropriate dose reduction are age, patient weight, and serum creatinine level, the same factors used as criteria for dose adjustment. However, in underdosed patients, the 3 factors did not meet the criteria for dose reduction. © 2018 Wiley Periodicals, Inc.

  9. A framework for organ dose estimation in x-ray angiography and interventional radiology based on dose-related data in DICOM structured reports

    NASA Astrophysics Data System (ADS)

    Omar, Artur; Bujila, Robert; Fransson, Annette; Andreo, Pedro; Poludniowski, Gavin

    2016-04-01

    Although interventional x-ray angiography (XA) procedures involve relatively high radiation doses that can lead to deterministic tissue reactions in addition to stochastic effects, convenient and accurate estimation of absorbed organ doses has traditionally been out of reach. This has mainly been due to the absence of practical means to access dose-related data that describe the physical context of the numerous exposures during an XA procedure. The present work provides a comprehensive and general framework for the determination of absorbed organ dose, based on non-proprietary access to dose-related data by utilizing widely available DICOM radiation dose structured reports. The framework comprises a straightforward calculation workflow to determine the incident kerma and reconstruction of the geometrical relation between the projected x-ray beam and the patient’s anatomy. The latter is difficult in practice, as the position of the patient on the table top is unknown. A novel patient-specific approach for reconstruction of the patient position on the table is presented. The proposed approach was evaluated for 150 patients by comparing the estimated position of the primary irradiated organs (the target organs) with their position in clinical DICOM images. The approach is shown to locate the target organ position with a mean (max) deviation of 1.3 (4.3), 1.8 (3.6) and 1.4 (2.9) cm for neurovascular, adult and paediatric cardiovascular procedures, respectively. To illustrate the utility of the framework for systematic and automated organ dose estimation in routine clinical practice, a prototype implementation of the framework with Monte Carlo simulations is included.

  10. TH-E-209-00: Radiation Dose Monitoring and Protocol Management

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    Radiation dose monitoring solutions have opened up new opportunities for medical physicists to be more involved in modern clinical radiology practices. In particular, with the help of comprehensive radiation dose data, data-driven protocol management and informed case follow up are now feasible. Significant challenges remain however and the problems faced by medical physicists are highly heterogeneous. Imaging systems from multiple vendors and a wide range of vintages co-exist in the same department and employ data communication protocols that are not fully standardized or implemented making harmonization complex. Many different solutions for radiation dose monitoring have been implemented by imaging facilitiesmore » over the past few years. Such systems are based on commercial software, home-grown IT solutions, manual PACS data dumping, etc., and diverse pathways can be used to bring the data to impact clinical practice. The speakers will share their experiences with creating or tailoring radiation dose monitoring/management systems and procedures over the past few years, which vary significantly in design and scope. Topics to cover: (1) fluoroscopic dose monitoring and high radiation event handling from a large academic hospital; (2) dose monitoring and protocol optimization in pediatric radiology; and (3) development of a home-grown IT solution and dose data analysis framework. Learning Objectives: Describe the scope and range of radiation dose monitoring and protocol management in a modern radiology practice Review examples of data available from a variety of systems and how it managed and conveyed. Reflect on the role of the physicist in radiation dose awareness.« less

  11. Dose Transition Pathways: The Missing Link Between Complex Dose-Finding Designs and Simple Decision-Making.

    PubMed

    Yap, Christina; Billingham, Lucinda J; Cheung, Ying Kuen; Craddock, Charlie; O'Quigley, John

    2017-12-15

    The ever-increasing pace of development of novel therapies mandates efficient methodologies for assessment of their tolerability and activity. Evidence increasingly support the merits of model-based dose-finding designs in identifying the recommended phase II dose compared with conventional rule-based designs such as the 3 + 3 but despite this, their use remains limited. Here, we propose a useful tool, dose transition pathways (DTP), which helps overcome several commonly faced practical and methodologic challenges in the implementation of model-based designs. DTP projects in advance the doses recommended by a model-based design for subsequent patients (stay, escalate, de-escalate, or stop early), using all the accumulated information. After specifying a model with favorable statistical properties, we utilize the DTP to fine-tune the model to tailor it to the trial's specific requirements that reflect important clinical judgments. In particular, it can help to determine how stringent the stopping rules should be if the investigated therapy is too toxic. Its use to design and implement a modified continual reassessment method is illustrated in an acute myeloid leukemia trial. DTP removes the fears of model-based designs as unknown, complex systems and can serve as a handbook, guiding decision-making for each dose update. In the illustrated trial, the seamless, clear transition for each dose recommendation aided the investigators' understanding of the design and facilitated decision-making to enable finer calibration of a tailored model. We advocate the use of the DTP as an integral procedure in the co-development and successful implementation of practical model-based designs by statisticians and investigators. Clin Cancer Res; 23(24); 7440-7. ©2017 AACR . ©2017 American Association for Cancer Research.

  12. Vitamin D dose response is underestimated by Endocrine Society's Clinical Practice Guideline.

    PubMed

    McKenna, Malachi J; Murray, Barbara F

    2013-06-01

    The recommended daily intakes of vitamin D according to the recent Clinical Practice Guideline (CPG) of the Endocrine Society are three- to fivefold higher than the Institute of Medicine (IOM) report. We speculated that these differences could be explained by different mathematical approaches to the vitamin D dose response. Studies were selected if the daily dose was ≤2000 IU/day, the duration exceeded 3 months, and 25-hydroxyvitamin D (25OHD) concentrations were measured at baseline and post-therapy. The rate constant was estimated according to the CPG approach. The achieved 25OHD result was estimated according to the following: i) the regression equation approach of the IOM; ii) the regression approach of the Vitamin D Supplementation in Older Subjects (ViDOS) study; and iii) the CPG approach using a rate constant of 2.5 (CPG2.5) and a rate constant of 5.0 (CPG5.0). The difference between the expected and the observed 25OHD result was expressed as a percentage of observed and analyzed for significance against a value of 0% for the four groups. Forty-one studies were analyzed. The mean (95% CI) rate constant was 5.3 (4.4-6.2) nmol/l per 100 IU per day, on average twofold higher than the CPG rate constant. The mean (95% CI) for the difference between the expected and observed expressed as a percentage of observed was as follows: i) IOM, -7 (-16,+2)% (t=1.64, P=0.110); ii) ViDOS, +2 (-8,+12)% (t=0.40, P=0.69); iii) CPG2.5, -21 (-27,-15)% (t=7.2, P<0.0001); and iv) CPG5.0+3 (-4,+10)% (t=0.91, P=0.366). The CPG 'rule of thumb' should be doubled to 5.0 nmol/l (2.0 ng/ml) per 100 IU per day, adopting a more risk-averse position.

  13. Effect of Streptokinase on Reperfusion After Acute Myocardial Infarction and Its Complications: An Ex-Post Facto Study

    PubMed Central

    Taheri, Leila; Zargham-Boroujeni, Ali; Jahromi, Marzieh Kargar; Charkhandaz, Maryam; Hojat, Mohsen

    2015-01-01

    Introduction: Emergency treatment of patients with acute myocardial infarction is very important. Streptokinase in Iran is often as the only clot-busting medication is used. The purpose of using streptokinase medication is to revive the ischemic heart tissue, although has dangerous complications too. Therefore, the present study aimed to determine the effect of streptokinase on reperfusion after acute myocardial infarction and its complications, has been designed and conducted. Materials and Methods: This is an Ex-post facto study. The study population included patients who suffer from acute myocardial infarction. The sample size was 300 patients, and 2 groups were matched, in variables of age, sex, underlying disease, frequencies and area of MI. Data collection did by researcher making questionnaire, that accept face and content validity by 10 expert researcher, the reliability was conducted with Spearman’s test (r=0.85) by Test-retest method. Data analysis did by SPSS software: V 12. Findings: Mean of EF in SK group was (46.15±8.11) and in control group was (43.11±12.57). Significant relationship was seen between SK, arrhythmia occurring and improve EF reperfusion by chi-square test (p=0.028), (p=0.020). The most arrhythmia in SK group was Ventricular Tachycardia (20.7%). Significant statistical relation between SK and mortality were found by Chi-square test (p=0.001). But a meaningful statistical relation was not found between SK and pulmonary edema incidence (p=0.071). Conclusions: Nurses of CCU should be aware about SK complications such as hypotension, bleeding and arrhythmias. Proposed compare SK and tissue plasminogen drug in reperfusion and complications effect. PMID:25946921

  14. Dosing Schedules for Pneumococcal Conjugate Vaccine

    PubMed Central

    2014-01-01

    Since second generation pneumococcal conjugate vaccines (PCVs) targeting 10 and 13 serotypes became available in 2010, the number of national policy makers considering these vaccines has steadily increased. An important consideration for a national immunization program is the timing and number of doses—the schedule—that will best prevent disease in the population. Data on disease epidemiology and the efficacy or effectiveness of PCV schedules are typically considered when choosing a schedule. Practical concerns, such as the existing vaccine schedule, and vaccine program performance are also important. In low-income countries, pneumococcal disease and deaths typically peak well before the end of the first year of life, making a schedule that provides PCV doses early in life (eg, a 6-, 10- and 14-week schedule) potentially the best option. In other settings, a schedule including a booster dose may address disease that peaks in the second year of life or may be seen to enhance a schedule already in place. A large and growing body of evidence from immunogenicity studies, as well as clinical trials and observational studies of carriage, pneumonia and invasive disease, has been systematically reviewed; these data indicate that schedules of 3 or 4 doses all work well, and that the differences between these regimens are subtle, especially in a mature program in which coverage is high and indirect (herd) effects help enhance protection provided directly by a vaccine schedule. The recent World Health Organization policy statement on PCVs endorsed a schedule of 3 primary doses without a booster or, as a new alternative, 2 primary doses with a booster dose. While 1 schedule may be preferred in a particular setting based on local epidemiology or practical considerations, achieving high coverage with 3 doses is likely more important than the specific timing of doses. PMID:24336059

  15. Impact of Pharmacy Practice Model Expansion on Pharmacokinetic Services: Optimization of Vancomycin Dosing and Improved Patient Safety.

    PubMed

    Han, Zhe; Pettit, Natasha N; Landon, Emily M; Brielmaier, Benjamin D

    2017-04-01

    Background: The impact of pharmacy interventions on optimizing vancomycin therapy has been described, however interventions vary among studies and the most optimal pharmacy practice model (PPM) for pharmacokinetic (PK) services has not been established. Objective: The purpose of this study is to demonstrate the value of 24 hours a day, 7 days a week (24/7) PK services. Methods: New PK services were implemented in 2 phases with institutional PPM expansion. Phase 1 included universal monitoring by pharmacists with recommendations made to prescribers during business hours. Phase 2 expanded clinical pharmacists' coverage to 24/7 and provided an optional 24/7 pharmacist-managed PK consult service. We compared vancomycin therapeutic trough attainment, dosing, and clinical and safety outcomes between phases 1 and 2 in adult inpatients receiving therapeutic intravenous vancomycin. Results. One hundred and fifty patients were included in each phase. Phase 2 had a greater proportion of vancomycin courses with therapeutic initial trough concentrations (27.5% vs 46.1%; p = 0.002), higher initial trough concentrations (10.9 mcg/mL vs 16.4 mcg/mL; p < 0.001), and optimized initial vancomycin dosing (13.5 mg/kg vs 16.2 mg/kg; p < 0.001). Phase 2 also saw significant reduction in the incidence of vancomycin-associated nephrotoxicity (21.1% vs 11.7%; p = 0.038). Dose optimization and improvement in initial target trough attainment were most notable among intensive care unit (ICU) patients. Conclusions. Our study demonstrated that 24/7 PK services implemented with institutional PPM expansion optimized vancomycin target trough attainment and improved patient safety.

  16. Implementing practice guidelines: lessons from public mental health settings.

    PubMed

    Parks, Joseph J

    2007-01-01

    There is evidence that state-of-the-art psychiatric treatments are not being translated into community settings, resulting in the de facto denial of up-to-date psychiatric care for many Americans with mental illness. Although multiple models of evidence-based care exist, little is known about how to disseminate information regarding these models to clinicians in real-world practice. Suggested solutions have included the use of published practice guidelines, such as the American Psychiatric Association Practice Guidelines and the Expert Consensus Guidelines, or algorithm-based programs, such as the Texas Medication Algorithm Project. Unfortunately, the real-world utility of practice guidelines tends to be limited, because their implementation depends entirely on practitioner self-motivation. Similarly, the use of algorithm-based programs may be limited by their pervasive high specificity, practitioner resistance, and various patient misperceptions. Another solution is the implementation of evidence-based practices (EBPs), such as the Substance Abuse and Mental Health Services Administration (SAMHSA) EBPs. However, states' use of the SAMHSA EBPs has been hampered by misalignment of the funding structure, lack of information regarding EBPs, high costs to train and supervise staff, staff turnover, and a lack of resources. As a result, federal and clinical/professional agencies have called for a change in the nation's mental health care delivery system, supplying persuasive arguments for the economic and clinical superiority of integrated care models. One such model, the Missouri Medical Risk Management (MRM) Program for Medicaid Recipients with Schizophrenia, currently assists patients identified as being at high risk for adverse medical and behavioral outcomes. Preliminary results from the Missouri MRM Program are described.

  17. SPECT-CT in routine clinical practice: increase in patient radiation dose compared with SPECT alone.

    PubMed

    Sharma, Punit; Sharma, Shekhar; Ballal, Sanjana; Bal, Chandrasekhar; Malhotra, Arun; Kumar, Rakesh

    2012-09-01

    To assess the patient radiation dose during routine clinical single-photon emission computed tomography-computed tomography (SPECT-CT) and measure the increase as compared with SPECT alone. Data pertaining to 357 consecutive patients who had undergone radioisotope imaging along with SPECT-CT of a selected volume were retrospectively evaluated. Dose of the injected radiopharmaceutical (MBq) was noted, and the effective dose (mSv) was calculated as per International Commission on Radiological Protection (ICRP) guidelines. The volume-weighted computed tomography dose index (CTDIvol) and dose length product of the CT were also assessed using standard phantoms. The effective dose (mSv) due to CT was calculated as the product of dose length product and a conversion factor depending on the region of investigation, using ICRP guidelines. The dose due to CT was compared among different investigations. The increase in effective dose was calculated as CT dose expressed as a percentage of radiopharmaceutical dose. The per-patient CT effective dose for different studies varied between 0.06 and 11.9 mSv. The mean CT effective dose was lowest for 99mTc-ethylene cysteine dimer brain SPECT-CT (0.9 ± 0.7) and highest for 99mTc-methylene diphosphonate bone SPECT-CT (4.2 ± 2.8). The increase in radiation dose (SPECT-CT vs. SPECT) varied widely (2.3-666.4% for 99mTc-tracers and 0.02-96.2% for 131I-tracers). However, the effective dose of CT in SPECT-CT was less than the values reported for conventional CT examinations of the same regions. Addition of CT to nuclear medicine imaging in the form of SPECT-CT increases the radiation dose to the patient, with the effective dose due to CT exceeding the effective dose of RP in many instances. Hence, appropriate utilization and optimization of the protocols of SPECT-CT is needed to maximize benefit to patients.

  18. Practical strategies when using a stable isotope labeled microtracer for absolute bioavailability assessment: A case study of a high oral dose clinical candidate GDC-0810.

    PubMed

    Chen, Buyun; Lu, Pingping; Freeman, Dugan; Gao, Yang; Choo, Edna; DeMent, Kevin; Savage, Scott; Zhang, Kelly; Milanwoski, Dennis; Liu, Lichuan; Dean, Brian; Deng, Yuzhong

    2018-05-30

    The pH labile metabolite, hydrophobicity, high oral dose and systematic exposure of GDC-0810 posed tremendous challenges to develop a LC-MS method for a stable isotope labeled aBA study. In this study, we explored practical solutions to balance stability and sensitivity and to cope with the impact of high C p.o. to C i.v. ratio on the labeling selection and assay dynamic range. A [ 13 C 9 ] GDC-0810 was synthesized to minimize the isotopic interference between PO dose, internal standard and I.V. microtracer. A highly sensitive LC-MS assay was validated for quantitation of [ 13 C 9 ] GDC-0810 from 5 to 1250 pg/mL. The optimized method was applied to a proof of concept cynomolgus monkey aBA study and the bioavailability calculated using microtracer dosing and regular dosing were similar to each other. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. A test of the IAEA code of practice for absorbed dose determination in photon and electron beams

    NASA Astrophysics Data System (ADS)

    Leitner, Arnold; Tiefenboeck, Wilhelm; Witzani, Josef; Strachotinsky, Christian

    1990-12-01

    The IAEA (International Atomic Energy Agency) code of practice TRS 277 gives recommendations for absorbed dose determination in high energy photon and electron beams based on the use of ionization chambers calibrated in terms of exposure of air kerma. The scope of the work was to test the code for cobalt 60 gamma radiation and for several radiation qualities at four different types of electron accelerators and to compare the ionization chamber dosimetry with ferrous sulphate dosimetry. The results show agreement between the two methods within about one per cent for all the investigated qualities. In addition the response of the TLD capsules of the IAEA/WHO TL dosimetry service was determined.

  20. 42 CFR 82.3 - What Are the Requirements for Dose Reconstruction Under EEOICPA?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES METHODS FOR CONDUCTING DOSE... unrecorded doses, which are estimated using commonly practiced dose reconstruction methods and would have to...

  1. Integrating policy, disintegrating practice: water resources management in Botswana

    NASA Astrophysics Data System (ADS)

    Swatuk, Larry A.; Rahm, Dianne

    Botswana is generally regarded as an African ‘success story’. Nearly four decades of unabated economic growth, multi-party democracy, conservative decision-making and low-levels of corruption have made Botswana the darling of the international donor community. One consequence of rapid and sustained economic development is that water resources use and demands have risen dramatically in a primarily arid/semi-arid environment. Policy makers recognize that supply is limited and that deliberate steps must be taken to manage demand. To this end, and in line with other members of the Southern African Development Community (SADC), Botswana devised a National Water Master Plan (NWMP) and undertook a series of institutional and legal reforms throughout the 1990s so as to make water resources use more equitable, efficient and sustainable. In other words, the stated goal is to work toward Integrated Water Resources Management (IWRM) in both policy and practice. However, policy measures have had limited impact on de facto practice. This paper reflects our efforts to understand the disjuncture between policy and practice. The information presented here combines a review of primary and secondary literatures with key informant interviews. It is our view that a number of constraints-cultural, power political, managerial-combine to hinder efforts toward sustainable forms of water resources use. If IWRM is to be realized in the country, these constraints must be overcome. This, however, is no small task.

  2. Occupational Exposure of the Eye Lens in Interventional Procedures: How to Assess and Manage Radiation Dose.

    PubMed

    Ciraj-Bjelac, Olivera; Carinou, Eleftheria; Ferrari, Paolo; Gingaume, Merce; Merce, Marta Sans; O'Connor, Una

    2016-11-01

    Occupational exposure from interventional x-ray procedures is one of the areas in which increased eye lens exposure may occur. Accurate dosimetry is an important element to investigate the correlation of observed radiation effects with radiation dose, to verify the compliance with regulatory dose limits, and to optimize radiation protection practice. The objective of this work is to review eye lens dose levels in clinical practice that may occur from the use of ionizing radiation. The use of a dedicated eye lens dosimeter is the recommended methodology; however, in practice it cannot always be easily implemented. Alternatively, the eye lens dose could be assessed from measurements of other dosimetric quantities or other indirect parameters, such as patient dose. The practical implementation of monitoring eye lens doses and the use of adequate protective equipment still remains a challenge. The use of lead glasses with a good fit to the face, appropriate lateral coverage, and/or ceiling-suspended screens is recommended in workplaces with potential high eye lens doses. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  3. EYE LENS DOSIMETRY FOR FLUOROSCOPICALLY GUIDED CLINICAL PROCEDURES: PRACTICAL APPROACHES TO PROTECTION AND DOSE MONITORING.

    PubMed

    Martin, Colin J

    2016-06-01

    Doses to the eye lenses of clinicians undertaking fluoroscopically guided procedures can exceed the dose annual limit of 20 mSv, so optimisation of radiation protection is essential. Ceiling-suspended shields and disposable radiation absorbing pads can reduce eye dose by factors of 2-7. Lead glasses that shield against exposures from the side can lower doses by 2.5-4.5 times. Training in effective use of protective devices is an essential element in achieving good protection and acceptable eye doses. Effective methods for dose monitoring are required to identify protection issues. Dosemeters worn adjacent to the eye provide the better option for interventional clinicians, but an unprotected dosemeter worn at the neck will give an indication of eye dose that is adequate for most interventional staff. Potential requirements for protective devices and dose monitoring can be determined from risk assessments using generic values for dose linked to examination workload. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  4. Efficacy and persistence of low-dose mirabegron (25 mg) in patients with overactive bladder: analysis in a real-world urological practice.

    PubMed

    Shen, Yuan Chi; Wang, Hung Jen; Chuang, Yao Chi

    2018-06-07

    Mirabegron is a relatively new drug to treat overactive bladder (OAB). The therapeutic doses are between 25 and 100 mg in clinical trials. We aimed to evaluate the efficacy and persistence of low-dose mirabegron (25 mg) in patients with OAB in daily urological practice. The study was a retrospective consecutive cohort of 177 OAB patients (101 male and 76 female) treated with 25 mg of mirabegron mg since January 2016 to November 2016. The therapeutic outcomes were assessed at baseline, 4, 12, and 24 weeks. Mirabegron usage was associated with a statistically significant decrease in Overactive Bladder Symptom Score, Urgency Severity Score, urge urinary incontinence, International Prostate Symptom Score (both storage and voiding symptom) at 4-week follow-up, and the therapeutic effects were further improved at 12- and 24-week follow-up. Among them, 118 patients (66.7%) and 84 patients (47.5%) were maintained on mirabegron therapy for more than 3 and 6 months, respectively. However, 29 patients (16%) had poor response with drug discontinuation within 3 months and 8 patients (4.5%) stopped medication due to adverse effects. The overall side effect was 10.2%, and the most common side effect was elevated blood pressure (2.8%) and increased post-void residual (2.8%). Between male and female patients, there was no statistical difference of symptom improvement and drug persistence rate. Low-dose mirabegron (25 mg) improves clinical outcomes in two-thirds of OAB patients with good safety profile and high persistence in daily urological practice. The therapeutic effect is similar between the genders.

  5. Tumor susceptibility in two mouse strains with varying doses of carcinogen

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bernfeld, P.; Homburger, F.

    Administration of 3-methylcholanthrene to C3H/HeJ and C57BL/6J mice at four dose levels over a 1:125 range resulted in a practically equal tumor response in both strains at all dose levels. Using a different method of carcinogen administration, a reversal of tumor susceptibility was found when varying the dose of carcinogen, a phenomenon not observed by us. Our study suggests that Prehn and Lawler's results may have been influenced, at least in part, by the practice of the latter authors to exclude data of substantial numbers of tumor-free mice from the evaluation. (JMT)

  6. CT dose reduction in children.

    PubMed

    Vock, Peter

    2005-11-01

    World wide, the number of CT studies in children and the radiation exposure by CT increases. The same energy dose has a greater biological impact in children than in adults, and scan parameters have to be adapted to the smaller diameter of the juvenile body. Based on seven rules, a practical approach to paediatric CT is shown: Justification and patient preparation are important steps before scanning, and they differ from the preparation of adult patients. The subsequent choice of scan parameters aims at obtaining the minimal signal-to-noise ratio and volume coverage needed in a specific medical situation; exposure can be divided in two aspects: the CT dose index determining energy deposition per rotation and the dose-length product (DLP) determining the volume dose. DLP closely parallels the effective dose, the best parameter of the biological impact. Modern scanners offer dose modulation to locally minimise exposure while maintaining image quality. Beyond the selection of the physical parameters, the dose can be kept low by scanning the minimal length of the body and by avoiding any non-qualified repeated scanning of parts of the body. Following these rules, paediatric CT examinations of good quality can be obtained at a reasonable cost of radiation exposure.

  7. Confectionery-based dose forms.

    PubMed

    Tangso, Kristian J; Ho, Quy Phuong; Boyd, Ben J

    2015-01-01

    Conventional dosage forms such as tablets, capsules and syrups are prescribed in the normal course of practice. However, concerns about patient preferences and market demands have given rise to the exploration of novel unconventional dosage forms. Among these, confectionery-based dose forms have strong potential to overcome compliance problems. This report will review the availability of these unconventional dose forms used in treating the oral cavity and for systemic drug delivery, with a focus on medicated chewing gums, medicated lollipops, and oral bioadhesive devices. The aim is to stimulate increased interest in the opportunities for innovative new products that are available to formulators in this field, particularly for atypical patient populations.

  8. Right dose, right now: using big data to optimize antibiotic dosing in the critically ill.

    PubMed

    Elbers, Paul W G; Girbes, Armand; Malbrain, Manu L N G; Bosman, Rob

    2015-01-01

    Antibiotics save lives and are essential for the practice of intensive care medicine. Adequate antibiotic treatment is closely related to outcome. However this is challenging in the critically ill, as their pharmacokinetic profile is markedly altered. Therefore, it is surprising that critical care physicians continue to rely on standard dosing regimens for every patient, regardless of the actual clinical situation. This review outlines the pharmacokinetic and pharmacodynamic principles that underlie the need for individualized and personalized drug dosing. At present, therapeutic drug monitoring may be of help, but has major disadvantages, remains unavailable for most antibiotics and has produced mixed results. We therefore propose the AutoKinetics concept, taking decision support for antibiotic dosing back to the bedside. By direct interaction with electronic patient records, this opens the way for the use of big data for providing the right dose at the right time in each patient.

  9. Mathematical optimization of high dose-rate brachytherapy—derivation of a linear penalty model from a dose-volume model

    NASA Astrophysics Data System (ADS)

    Morén, B.; Larsson, T.; Carlsson Tedgren, Å.

    2018-03-01

    High dose-rate brachytherapy is a method for cancer treatment where the radiation source is placed within the body, inside or close to a tumour. For dose planning, mathematical optimization techniques are being used in practice and the most common approach is to use a linear model which penalizes deviations from specified dose limits for the tumour and for nearby organs. This linear penalty model is easy to solve, but its weakness lies in the poor correlation of its objective value and the dose-volume objectives that are used clinically to evaluate dose distributions. Furthermore, the model contains parameters that have no clear clinical interpretation. Another approach for dose planning is to solve mixed-integer optimization models with explicit dose-volume constraints which include parameters that directly correspond to dose-volume objectives, and which are therefore tangible. The two mentioned models take the overall goals for dose planning into account in fundamentally different ways. We show that there is, however, a mathematical relationship between them by deriving a linear penalty model from a dose-volume model. This relationship has not been established before and improves the understanding of the linear penalty model. In particular, the parameters of the linear penalty model can be interpreted as dual variables in the dose-volume model.

  10. Eye lens dosimetry in interventional cardiology: results of staff dose measurements and link to patient dose levels.

    PubMed

    Antic, V; Ciraj-Bjelac, O; Rehani, M; Aleksandric, S; Arandjic, D; Ostojic, M

    2013-01-01

    Workers involved in interventional cardiology procedures receive high eye lens dose if protection is not used. Currently, there is no suitable method for routine use for the measurement of eye dose. Since most angiography machines are equipped with suitable patient dosemeters, deriving factors linking staff eye doses to the patient doses can be helpful. In this study the patient kerma-area product, cumulative dose at an interventional reference point and eye dose in terms of Hp(3) of the cardiologists, nurses and radiographers for interventional cardiology procedures have been measured. Correlations between the patient dose and the staff eye dose were obtained. The mean eye dose was 121 µSv for the first operator, 33 µSv for the second operator/nurse and 12 µSv for radiographer. Normalised eye lens doses per unit kerma-area product were 0.94 µSv Gy⁻¹ cm⁻² for the first operator, 0.33 µSv Gy⁻¹ cm⁻² for the second operator/nurse and 0.16 µSv Gy⁻¹ cm⁻² for radiographers. Statistical analysis indicated that there is a weak but significant (p < 0.01) correlation between the eye dose and the kerma-area product for all three staff categories. These values are based on a local practice and may provide useful reference for other studies for validation and for wider utilisation in assessing the eye dose using patient dose values.

  11. Practical dose point-based methods to characterize dose distribution in a stationary elliptical body phantom for a cone-beam C-arm CT system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Choi, Jang-Hwan, E-mail: jhchoi21@stanford.edu; Constantin, Dragos; Ganguly, Arundhuti

    2015-08-15

    Purpose: To propose new dose point measurement-based metrics to characterize the dose distributions and the mean dose from a single partial rotation of an automatic exposure control-enabled, C-arm-based, wide cone angle computed tomography system over a stationary, large, body-shaped phantom. Methods: A small 0.6 cm{sup 3} ion chamber (IC) was used to measure the radiation dose in an elliptical body-shaped phantom made of tissue-equivalent material. The IC was placed at 23 well-distributed holes in the central and peripheral regions of the phantom and dose was recorded for six acquisition protocols with different combinations of minimum kVp (109 and 125 kVp)more » and z-collimator aperture (full: 22.2 cm; medium: 14.0 cm; small: 8.4 cm). Monte Carlo (MC) simulations were carried out to generate complete 2D dose distributions in the central plane (z = 0). The MC model was validated at the 23 dose points against IC experimental data. The planar dose distributions were then estimated using subsets of the point dose measurements using two proposed methods: (1) the proximity-based weighting method (method 1) and (2) the dose point surface fitting method (method 2). Twenty-eight different dose point distributions with six different point number cases (4, 5, 6, 7, 14, and 23 dose points) were evaluated to determine the optimal number of dose points and their placement in the phantom. The performances of the methods were determined by comparing their results with those of the validated MC simulations. The performances of the methods in the presence of measurement uncertainties were evaluated. Results: The 5-, 6-, and 7-point cases had differences below 2%, ranging from 1.0% to 1.7% for both methods, which is a performance comparable to that of the methods with a relatively large number of points, i.e., the 14- and 23-point cases. However, with the 4-point case, the performances of the two methods decreased sharply. Among the 4-, 5-, 6-, and 7-point cases, the 7-point

  12. TH-E-209-02: Dose Monitoring and Protocol Optimization: The Pediatric Perspective

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    MacDougall, R.

    Radiation dose monitoring solutions have opened up new opportunities for medical physicists to be more involved in modern clinical radiology practices. In particular, with the help of comprehensive radiation dose data, data-driven protocol management and informed case follow up are now feasible. Significant challenges remain however and the problems faced by medical physicists are highly heterogeneous. Imaging systems from multiple vendors and a wide range of vintages co-exist in the same department and employ data communication protocols that are not fully standardized or implemented making harmonization complex. Many different solutions for radiation dose monitoring have been implemented by imaging facilitiesmore » over the past few years. Such systems are based on commercial software, home-grown IT solutions, manual PACS data dumping, etc., and diverse pathways can be used to bring the data to impact clinical practice. The speakers will share their experiences with creating or tailoring radiation dose monitoring/management systems and procedures over the past few years, which vary significantly in design and scope. Topics to cover: (1) fluoroscopic dose monitoring and high radiation event handling from a large academic hospital; (2) dose monitoring and protocol optimization in pediatric radiology; and (3) development of a home-grown IT solution and dose data analysis framework. Learning Objectives: Describe the scope and range of radiation dose monitoring and protocol management in a modern radiology practice Review examples of data available from a variety of systems and how it managed and conveyed. Reflect on the role of the physicist in radiation dose awareness.« less

  13. Dose in x-ray computed tomography

    NASA Astrophysics Data System (ADS)

    Kalender, Willi A.

    2014-02-01

    Radiation dose in x-ray computed tomography (CT) has become a topic of high interest due to the increasing numbers of CT examinations performed worldwide. This review aims to present an overview of current concepts for both scanner output metrics and for patient dosimetry and will comment on their strengths and weaknesses. Controversial issues such as the appropriateness of the CT dose index (CTDI) are discussed in detail. A review of approaches to patient dose assessment presently in practice, of the dose levels encountered and options for further dose optimization are also given and discussed. Patient dose assessment remains a topic for further improvement and for international consensus. All approaches presently in use are based on Monte Carlo (MC) simulations. Estimates for effective dose are established, but they are crude and not patient-specific; organ dose estimates are rarely available. Patient- and organ-specific dose estimates can be provided with adequate accuracy and independent of CTDI phantom measurements by fast MC simulations. Such information, in particular on 3D dose distributions, is important and helpful in optimization efforts. Dose optimization has been performed very successfully in recent years and even resulted in applications with effective dose values of below 1 mSv. In general, a trend towards lower dose values based on technical innovations has to be acknowledged. Effective dose values are down to clearly below 10 mSv on average, and there are a number of applications such as cardiac and pediatric CT which are performed routinely below 1 mSv on modern equipment.

  14. GOSPEL 2 - Colchicine for the treatment of gout flares in France - a GOSPEL survey subgroup analysis. Doses used in common practices regardless of renal impairment and age.

    PubMed

    Pascart, Tristan; Lancrenon, Sylvie; Lanz, Sabine; Delva, Catherine; Guggenbuhl, Pascal; Lambert, Charles; Aubert, Jean-Pierre; Saraux, Alain; Ea, Hang-Korng; Lioté, Frédéric

    2016-12-01

    The objective of this sub-study was to assess the use of colchicine for the treatment of gout flares in real life conditions in the GOSPEL cohort following the 2006 EULAR recommendations for gout management. This national cross-sectional epidemiologic survey included outpatients with gout suffering from acute flare followed by randomly selected primary care physicians (n=398) and private practice rheumatologists (n=109) between October 2008 and September 2009 in France. Data regarding patient characteristics and treatment prescription was collected by each physician. Glomerular filtration rate (eGFR) was estimated using the Cockroft-Gault formula. Patients included in the survey for a gout flare filled in a specific self-questionnaire including colchicine effective intake and pain relief (numeric scale). This analysis focused on the 349 patients presenting with gout flare and treated with colchicine. Mean (±SD) prescribed dose of colchicine was 2.8 (±0.7) mg within the first 24hours and the cumulative dose over the first three days of treatment was 6.9 (±1.8) mg. Patients with mild decline in eGFR (eDFG 60-80mL/min) were prescribed an average initial dose of 2.8mg (±0.8) mg (n=58), 2.7 (±0.8) mg in chronic kidney disease (CKD) stage 3 (n=43) and 2.5 (±0.7) mg in CKD stage 4 (n=2). Cumulative doses of colchicine did not take into account either renal impairment or age. This study draws attention to some misuse of colchicine in daily practice and the prescription of excessive doses especially in case of renal impairment. eGFR should be enforced in daily practice. Copyright © 2016 Société française de rhumatologie. Published by Elsevier SAS. All rights reserved.

  15. Defined daily doses (DDD) do not accurately reflect opioid doses used in contemporary chronic pain treatment.

    PubMed

    Nielsen, Suzanne; Gisev, Natasa; Bruno, Raimondo; Hall, Wayne; Cohen, Milton; Larance, Briony; Campbell, Gabrielle; Shanahan, Marian; Blyth, Fiona; Lintzeris, Nicholas; Pearson, Sallie; Mattick, Richard; Degenhardt, Louisa

    2017-05-01

    To assess how well the defined daily dose (DDD) metric reflects opioid utilisation among chronic non-cancer pain patients. Descriptive, cross-sectional study, utilising a 7-day medication diary. Community-based treatment settings, Australia. A sample of 1101 people prescribed opioids for chronic non-cancer pain. Opioid dose data was collected via a self-completed 7-day medication diary capturing names, strengths and doses of each medication taken in the past week. Median daily dose was calculated for each opioid. Comparisons were made to the World Health Organization's (WHO) DDD metric. WHO DDDs ranged from 0.6 to 7.1 times the median opioid doses used by the sample. For transdermal fentanyl and oral hydromorphone, the median dose was comparable with the DDD. The DDD for methadone was 0.6 times lower than the median doses used by this sample of chronic pain patients. In contrast, the DDD for oxycodone and transdermal buprenorphine, the most commonly used strong opioids for chronic pain in Australia, was two to seven times higher than actual doses used. For many opioids, there are key differences between the actual doses used in clinical practice and the WHO's DDDs. The interpretation of opioid utilisation studies using population-level DDDs may be limited, and a recalibration of the DDD for many opioids or the reporting of opioid utilisation in oral morphine equivalent doses is recommended. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  16. Dose and timing in neurorehabilitation: Prescribing motor therapy after stroke

    PubMed Central

    Lang, Catherine E.; Lohse, Keith R.; Birkenmeier, Rebecca L.

    2015-01-01

    Purpose of the review Prescribing the most appropriate dose of motor therapy for individual patients is a challenge because minimal data are available and a large number of factors are unknown. This review explores the concept of dose and reviews the most recent findings in the field of neurorehabilitation, with a focus on relearning motor skills post stroke. Recent findings Appropriate dosing involves the prescription of a specific amount of an active ingredient, at a specific frequency and duration. Dosing parameters, particularly amount, are not well-defined or quantified in most studies. Compiling data across studies indicates a positive, moderate dose-response relationship, indicating that more movement practice results in better outcomes. This relationship is confounded by time post stroke however, where longer durations of scheduled therapy may not be beneficial in the first few hours, days, and/or weeks. Summary These findings suggest that substantially more movement practice may be necessary to achieve better outcomes for people living with the disabling consequences of stroke. Preclinical investigations are needed to elucidate many of the unknowns and allow for a more biologically-driven rehabilitation prescription process. Likewise, clinical investigations are needed to determine the dose-response relationships and examine the potential dose-timing interaction in humans. PMID:26402404

  17. Using lean to improve medication administration safety: in search of the "perfect dose".

    PubMed

    Ching, Joan M; Long, Christina; Williams, Barbara L; Blackmore, C Craig

    2013-05-01

    At Virginia Mason Medical Center (Seattle), the Collaborative Alliance for Nursing Outcomes (CALNOC) Medication Administration Accuracy Quality Study was used in combination with Lean quality improvement efforts to address medication administration safety. Lean interventions were targeted at improving the medication room layout, applying visual controls, and implementing nursing standard work. The interventions were designed to prevent medication administration errors through improving six safe practices: (1) comparing medication with medication administration record, (2) labeling medication, (3) checking two forms of patient identification, (4) explaining medication to patient, (5) charting medication immediately, and (6) protecting the process from distractions/interruptions. Trained nurse auditors observed 9,244 doses for 2,139 patients. Following the intervention, the number of safe-practice violations decreased from 83 violations/100 doses at baseline (January 2010-March 2010) to 42 violations/100 doses at final follow-up (July 2011-September 2011), resulting in an absolute risk reduction of 42 violations/100 doses (95% confidence interval [CI]: 35-48), p < .001). The number of medication administration errors decreased from 10.3 errors/100 doses at baseline to 2.8 errors/100 doses at final follow-up (absolute risk reduction: 7 violations/100 doses [95% CI: 5-10, p < .001]). The "perfect dose" score, reflecting compliance with all six safe practices and absence of any of the eight medication administration errors, improved from 37 in compliance/100 doses at baseline to 68 in compliance/100 doses at the final follow-up. Lean process improvements coupled with direct observation can contribute to substantial decreases in errors in nursing medication administration.

  18. SU-C-206-07: A Practical Sparse View Ultra-Low Dose CT Acquisition Scheme for PET Attenuation Correction in the Extended Scan Field-Of-View

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miao, J; Fan, J; Gopinatha Pillai, A

    Purpose: To further reduce CT dose, a practical sparse-view acquisition scheme is proposed to provide the same attenuation estimation as higher dose for PET imaging in the extended scan field-of-view. Methods: CT scans are often used for PET attenuation correction and can be acquired at very low CT radiation dose. Low dose techniques often employ low tube voltage/current accompanied with a smooth filter before backprojection to reduce CT image noise. These techniques can introduce bias in the conversion from HU to attenuation values, especially in the extended CT scan field-of-view (FOV). In this work, we propose an ultra-low dose CTmore » technique for PET attenuation correction based on sparse-view acquisition. That is, instead of an acquisition of full amount of views, only a fraction of views are acquired. We tested this technique on a 64-slice GE CT scanner using multiple phantoms. CT scan FOV truncation completion was performed based on the published water-cylinder extrapolation algorithm. A number of continuous views per rotation: 984 (full), 246, 123, 82 and 62 have been tested, corresponding to a CT dose reduction of none, 4x, 8x, 12x and 16x. We also simulated sparse-view acquisition by skipping views from the fully-acquired view data. Results: FBP reconstruction with Q. AC filter on reduced views in the full extended scan field-of-view possesses similar image quality to the reconstruction on acquired full view data. The results showed a further potential for dose reduction compared to the full acquisition, without sacrificing any significant attenuation support to the PET. Conclusion: With the proposed sparse-view method, one can potential achieve at least 2x more CT dose reduction compared to the current Ultra-Low Dose (ULD) PET/CT protocol. A pre-scan based dose modulation scheme can be combined with the above sparse-view approaches, which can even further reduce the CT scan dose during a PET/CT exam.« less

  19. Monte Carlo modeling of a 6 and 18 MV Varian Clinac medical accelerator for in-field and out-of-field dose calculations: development and validation

    PubMed Central

    Bednarz, Bryan; Xu, X George

    2012-01-01

    There is a serious and growing concern about the increased risk of radiation-induced second cancers and late tissue injuries associated with radiation treatment. To better understand and to more accurately quantify non-target organ doses due to scatter and leakage radiation from medical accelerators, a detailed Monte Carlo model of the medical linear accelerator is needed. This paper describes the development and validation of a detailed accelerator model of the Varian Clinac operating at 6 and 18 MV beam energies. Over 100 accelerator components have been defined and integrated using the Monte Carlo code MCNPX. A series of in-field and out-of-field dose validation studies were performed. In-field dose distributions calculated using the accelerator models were tuned to match measurement data that are considered the de facto ‘gold standard’ for the Varian Clinac accelerator provided by the manufacturer. Field sizes of 4 cm × 4 cm, 10 cm × 10 cm, 20 cm × 20 cm and 40 cm × 40 cm were considered. The local difference between calculated and measured dose on the percent depth dose curve was less than 2% for all locations. The local difference between calculated and measured dose on the dose profile curve was less than 2% in the plateau region and less than 2 mm in the penumbra region for all locations. Out-of-field dose profiles were calculated and compared to measurement data for both beam energies for field sizes of 4 cm × 4 cm, 10 cm × 10 cm and 20 cm × 20 cm. For all field sizes considered in this study, the average local difference between calculated and measured dose for the 6 and 18 MV beams was 14 and 16%, respectively. In addition, a method for determining neutron contamination in the 18 MV operating model was validated by comparing calculated in-air neutron fluence with reported calculations and measurements. The average difference between calculated and measured neutron fluence was 20%. As one of the most detailed accelerator models for both in

  20. MO-DE-204-03: Radiology Dose Optimisation - An Australian Perspective

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schick, D.

    2016-06-15

    The main topic of the session is to show how dose optimization is being implemented in various regions of the world, including Europe, Australia, North America and other regions. A multi-national study conducted under International Atomic Energy Agency (IAEA) across more than 50 less resourced countries gave insight into patient radiation doses and safety practices in CT, mammography, radiography and interventional procedures, both for children and adults. An important outcome was the capability development on dose assessment and management. An overview of recent European projects related to CT radiation dose and optimization both to adults and children will be presented.more » Existing data on DRLs together with a European methodology proposed on establishing and using DRLs for paediatric radiodiagnostic imaging and interventional radiology practices will be shown. Compared with much of Europe at least, many Australian imaging practices are relatively new to the task of diagnostic imaging dose optimisation. In 2008 the Australian Government prescribed a requirement to periodically compare patient radiation doses with diagnostic reference levels (DRLs), where DRLs have been established. Until recently, Australia had only established DRLs for computed tomography (CT). Regardless, both professional society and individual efforts to improved data collection and develop optimisation strategies across a range of modalities continues. Progress in this field, principally with respect to CT and interventional fluoroscopy will be presented. In the US, dose reduction and optimization efforts for computed tomography have been promoted and mandated by several organizations and accrediting entities. This presentation will cover the general motivation, implementation, and implications of such efforts. Learning Objectives: Understand importance of the dose optimization in Diagnostic Radiology. See how this goal is achieved in different regions of the World. Learn about the

  1. Fundamentals of Transcranial Electric and Magnetic Stimulation Dose: Definition, Selection, and Reporting Practices

    PubMed Central

    Peterchev, Angel V.; Wagner, Timothy A.; Miranda, Pedro C.; Nitsche, Michael A.; Paulus, Walter; Lisanby, Sarah H.; Pascual-Leone, Alvaro; Bikson, Marom

    2011-01-01

    The growing use of transcranial electric and magnetic (EM) brain stimulation in basic research and in clinical applications necessitates a clear understanding of what constitutes the dose of EM stimulation and how it should be reported. The biological effects of EM stimulation are mediated through an electromagnetic field injected (via electric stimulation) or induced (via magnetic stimulation) in the body. Therefore, transcranial EM stimulation dose ought to be defined by all parameters of the stimulation device that affect the electromagnetic field generated in the body, including the stimulation electrode or coil configuration parameters: shape, size, position, and electrical properties, as well as the electrode or coil current (or voltage) waveform parameters: pulse shape, amplitude, width, polarity, and repetition frequency; duration of and interval between bursts or trains of pulses; total number of pulses; and interval between stimulation sessions and total number of sessions. Knowledge of the electromagnetic field generated in the body may not be sufficient but is necessary to understand the biological effects of EM stimulation. We believe that reporting of EM stimulation dose should be guided by the principle of reproducibility: sufficient information about the stimulation parameters should be provided so that the dose can be replicated. This paper provides fundamental definition and principles for reporting of dose that encompass any transcranial EM brain stimulation protocol. PMID:22305345

  2. Fundamentals of transcranial electric and magnetic stimulation dose: definition, selection, and reporting practices.

    PubMed

    Peterchev, Angel V; Wagner, Timothy A; Miranda, Pedro C; Nitsche, Michael A; Paulus, Walter; Lisanby, Sarah H; Pascual-Leone, Alvaro; Bikson, Marom

    2012-10-01

    The growing use of transcranial electric and magnetic (EM) brain stimulation in basic research and in clinical applications necessitates a clear understanding of what constitutes the dose of EM stimulation and how it should be reported. This paper provides fundamental definitions and principles for reporting of dose that encompass any transcranial EM brain stimulation protocol. The biologic effects of EM stimulation are mediated through an electromagnetic field injected (via electric stimulation) or induced (via magnetic stimulation) in the body. Therefore, transcranial EM stimulation dose ought to be defined by all parameters of the stimulation device that affect the electromagnetic field generated in the body, including the stimulation electrode or coil configuration parameters: shape, size, position, and electrical properties, as well as the electrode or coil current (or voltage) waveform parameters: pulse shape, amplitude, width, polarity, and repetition frequency; duration of and interval between bursts or trains of pulses; total number of pulses; and interval between stimulation sessions and total number of sessions. Knowledge of the electromagnetic field generated in the body may not be sufficient but is necessary to understand the biologic effects of EM stimulation. We believe that reporting of EM stimulation dose should be guided by the principle of reproducibility: sufficient information about the stimulation parameters should be provided so that the dose can be replicated. Copyright © 2012 Elsevier Inc. All rights reserved.

  3. Radiation dose management in thoracic CT: an international survey.

    PubMed

    Molinari, Francesco; Tack, Denis M; Boiselle, Philip; Ngo, Long; Mueller-Mang, Christina; Litmanovich, Diana; Bankier, Alexander A

    2013-01-01

    We aimed to examine current practice patterns of international thoracic radiologists regarding radiation dose management in adult thoracic computed tomography (CT) examinations. An electronic questionnaire was sent to 800 members of five thoracic radiology societies in North America, Europe, Asia, and Latin America addressing radiation dose training and education, standard kVp and mAs settings for thoracic CT, dose reduction practices, clinical scenarios, and demographics. Of the 800 radiologists, 146 responded to our survey. Nearly half (66/146, 45% [95% confidence interval, 37%-53%]) had no formal training in dose reduction, with "self-study of the literature" being the most common form of training (54/146, 37% [29%-45%]). One hundred and seventeen (80% [74%-87%]) had automatic exposure control, and 76 (65% [56%-74%]) used it in all patients. Notably, most respondents (89% [84%-94%]) used a 120 to 125 kVp standard setting, whereas none used 140 kVp. The most common average dose-length-product (DLP) value was 150 to 249 mGy.cm (75/146, 51% [43%-59%]), and 59% (51%-67%) delivered less than 250 mGy.cm in a 70 kg patient. There was a tendency towards higher DLP values with multidetector-row CT. Age, gender, and pregnancy were associated more with dose reduction than weight and clinical indication. Efforts for reducing patient radiation dose are highly prevalent among thoracic radiologists. Areas for improvement include reduction of default tube current settings, reduction of anatomical scan coverage, greater use of automatic exposure control, and eventually, reduction of current reference dose values. Our study emphasizes the need for international guidelines to foster greater conformity in dose reduction by thoracic radiologists.

  4. Dose Estimating Application Software Modification: Additional Function of a Size-Specific Effective Dose Calculator and Auto Exposure Control.

    PubMed

    Kobayashi, Masanao; Asada, Yasuki; Matsubara, Kosuke; Suzuki, Shouichi; Matsunaga, Yuta; Haba, Tomonobu; Kawaguchi, Ai; Daioku, Tomihiko; Toyama, Hiroshi; Kato, Ryoichi

    2017-05-01

    Adequate dose management during computed tomography is important. In the present study, the dosimetric application software ImPACT was added to a functional calculator of the size-specific dose estimate and was part of the scan settings for the auto exposure control (AEC) technique. This study aimed to assess the practicality and accuracy of the modified ImPACT software for dose estimation. We compared the conversion factors identified by the software with the values reported by the American Association of Physicists in Medicine Task Group 204, and we noted similar results. Moreover, doses were calculated with the AEC technique and a fixed-tube current of 200 mA for the chest-pelvis region. The modified ImPACT software could estimate each organ dose, which was based on the modulated tube current. The ability to perform beneficial modifications indicates the flexibility of the ImPACT software. The ImPACT software can be further modified for estimation of other doses. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  5. Concepts for dose determination in flat-detector CT

    NASA Astrophysics Data System (ADS)

    Kyriakou, Yiannis; Deak, Paul; Langner, Oliver; Kalender, Willi A.

    2008-07-01

    Flat-detector computed tomography (FD-CT) scanners provide large irradiation fields of typically 200 mm in the cranio-caudal direction. In consequence, dose assessment according to the current definition of the computed tomography dose index CTDIL=100 mm, where L is the integration length, would demand larger ionization chambers and phantoms which do not appear practical. We investigated the usefulness of the CTDI concept and practical dosimetry approaches for FD-CT by measurements and Monte Carlo (MC) simulations. An MC simulation tool (ImpactMC, VAMP GmbH, Erlangen, Germany) was used to assess the dose characteristics and was calibrated with measurements of air kerma. For validation purposes measurements were performed on an Axiom Artis C-arm system (Siemens Medical Solutions, Forchheim, Germany) equipped with a flat detector of 40 cm × 30 cm. The dose was assessed for 70 kV and 125 kV in cylindrical PMMA phantoms of 160 mm and 320 mm diameter with a varying phantom length from 150 to 900 mm. MC simulation results were compared to the values obtained with a calibrated ionization chambers of 100 mm and 250 mm length and to thermoluminesence (TLD) dose profiles. The MCs simulations were used to calculate the efficiency of the CTDIL determination with respect to the desired CTDI∞. Both the MC simulation results and the dose distributions obtained by MC simulation were in very good agreement with the CTDI measurements and with the reference TLD profiles, respectively, to within 5%. Standard CTDI phantoms which have a z-extent of 150 mm underestimate the dose at the center by up to 55%, whereas a z-extent of >=600 mm appears to be sufficient for FD-CT; the baseline value of the respective profile was within 1% to the reference baseline. As expected, the measurements with ionization chambers of 100 mm and 250 mm offer a limited accuracy, whereas an increased integration length of >=600 mm appeared to be necessary to approximate CTDI∞ in within 1%. MC simulations

  6. Dosing of cytotoxic chemotherapy: impact of renal function estimates on dose.

    PubMed

    Dooley, M J; Poole, S G; Rischin, D

    2013-11-01

    Oncology clinicians are now routinely provided with an estimated glomerular filtration rate on pathology reports whenever serum creatinine is requested. The utility of using this for the dose determination of renally excreted drugs compared with other existing methods is needed to inform practice. Renal function was determined by [Tc(99m)]DTPA clearance in adult patients presenting for chemotherapy. Renal function was calculated using the 4-variable Modification of Diet in Renal Disease (4v-MDRD), Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI), Cockcroft and Gault (CG), Wright and Martin formulae. Doses for renal excreted cytotoxic drugs, including carboplatin, were calculated. The concordance of the renal function estimates according to the CKD classification with measured Tc(99m)DPTA clearance in 455 adults (median age 64.0 years: range 17-87 years) for the 4v-MDRD, CKD-EPI, CG, Martin and Wright formulae was 47.7%, 56.3%, 46.2%, 56.5% and 60.2%, respectively. Concordance for chemotherapy dose for these formulae was 89.0%, 89.5%, 85.1%, 89.9% and 89.9%, respectively. Concordance for carboplatin dose specifically was 66.4%, 71.4%, 64.0%, 73.8% and 73.2%. All bedside formulae provide similar levels of concordance in dosage selection for the renal excreted chemotherapy drugs when compared with the use of a direct measure of renal function.

  7. Modeling to optimize operational practices to limit shallow dose and dose to the lens at the Weldon Spring Site Remedial Action Project.

    PubMed

    Hillman, D J; Green, S W

    1994-10-01

    The Weldon Spring Site Remedial Action Project (WSSRAP) began remediation of its chemical plant buildings in June 1992. The chemical plant was used by the Atomic Energy Commission in the 1950's and 1960's to process uranium ore and natural thorium. Many remaining equipment surfaces were highly contaminated with uranium and thorium product residues, which are relatively weak gamma emitters, but are strong beta emitters that deposit the majority of their energy within the first centimeter of tissue. An essential part of the remediation, therefore, is to control the dose to the skin, extremities, and the lens of the eye from the broad range of betas emitted by uranium and thorium decay series radionuclides. The WSSRAP planned to quantitatively record the dose to the skin, extremities, and the lens of the eye, when warranted, through selection and use of appropriate passive dosimeters. That would not, however, constitute control. A direct-reading instrument was needed that could be used by field technicians to anticipate and prevent work methods and situations that would otherwise result in the unnecessary commitment of dose. However, the interpretation of real-time instrument readings produced by a broad spectrum of beta energies is typically challenging at best, particularly when the shallow dose rate and the lens dose rate are both of interest. The purpose of this effort was, therefore, to (1) select a direct-reading instrument for use in the buildings that could be used to provide rule-of-thumb action levels for field technicians, which, if exceeded, would warrant worker protective measures; (2) determine the approximate conversions between the instrument readings and the shallow (including extremity) dose rate and lens of the eye dose rate; and (3) specify protective measures and dosimetry for the lens of the eye, if warranted. Methods described in the literature are used to estimate action levels for direct instrument readings and to demonstrate that lens

  8. Improving Low-Dose Blood-Brain Barrier Permeability Quantification Using Sparse High-Dose Induced Prior for Patlak Model

    PubMed Central

    Fang, Ruogu; Karlsson, Kolbeinn; Chen, Tsuhan; Sanelli, Pina C.

    2014-01-01

    Blood-brain-barrier permeability (BBBP) measurements extracted from the perfusion computed tomography (PCT) using the Patlak model can be a valuable indicator to predict hemorrhagic transformation in patients with acute stroke. Unfortunately, the standard Patlak model based PCT requires excessive radiation exposure, which raised attention on radiation safety. Minimizing radiation dose is of high value in clinical practice but can degrade the image quality due to the introduced severe noise. The purpose of this work is to construct high quality BBBP maps from low-dose PCT data by using the brain structural similarity between different individuals and the relations between the high- and low-dose maps. The proposed sparse high-dose induced (shd-Patlak) model performs by building a high-dose induced prior for the Patlak model with a set of location adaptive dictionaries, followed by an optimized estimation of BBBP map with the prior regularized Patlak model. Evaluation with the simulated low-dose clinical brain PCT datasets clearly demonstrate that the shd-Patlak model can achieve more significant gains than the standard Patlak model with improved visual quality, higher fidelity to the gold standard and more accurate details for clinical analysis. PMID:24200529

  9. SU-F-P-19: Fetal Dose Estimate for a High-Dose Fluoroscopy Guided Intervention Using Modern Data Tools

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moirano, J

    Purpose: An accurate dose estimate is necessary for effective patient management after a fetal exposure. In the case of a high-dose exposure, it is critical to use all resources available in order to make the most accurate assessment of the fetal dose. This work will demonstrate a methodology for accurate fetal dose estimation using tools that have recently become available in many clinics, and show examples of best practices for collecting data and performing the fetal dose calculation. Methods: A fetal dose estimate calculation was performed using modern data collection tools to determine parameters for the calculation. The reference pointmore » air kerma as displayed by the fluoroscopic system was checked for accuracy. A cumulative dose incidence map and DICOM header mining were used to determine the displayed reference point air kerma. Corrections for attenuation caused by the patient table and pad were measured and applied in order to determine the peak skin dose. The position and depth of the fetus was determined by ultrasound imaging and consultation with a radiologist. The data collected was used to determine a normalized uterus dose from Monte Carlo simulation data. Fetal dose values from this process were compared to other accepted calculation methods. Results: An accurate high-dose fetal dose estimate was made. Comparison to accepted legacy methods were were within 35% of estimated values. Conclusion: Modern data collection and reporting methods ease the process for estimation of fetal dose from interventional fluoroscopy exposures. Many aspects of the calculation can now be quantified rather than estimated, which should allow for a more accurate estimation of fetal dose.« less

  10. Mode of Action (MOA) and Dose-Response Approaches for Nuclear Receptors

    EPA Science Inventory

    Abstract: The presence of sub-threshold doses for non-cancer and (in appropriate cases) cancer has been the dominant paradigm for the practice of risk assessment, but the application of dose-response modeling approaches that include a threshold have been questioned in a 2009 NRC ...

  11. Mammographic screening practices among Chinese-Australian women.

    PubMed

    Kwok, Cannas; Fethney, Judith; White, Kate

    2012-03-01

    To report mammographic screening practice among Chinese-Australian women, and to examine the relationship between demographic characteristics, acculturation factors (English proficiency and length of stay in Australia), cultural beliefs, and having a mammogram as recommended. Cross-sectional and descriptive. The study was conducted in 2009 in Sydney, Australia. Of 988 Chinese-Australian women over 18 years of age invited to participate in the study, 785 (79%) completed and returned the questionnaire. Of these women, 320 (40.8%) were in the target age range of 50 to 69 years. The Chinese Breast Cancer Screening Beliefs Questionnaire (CBCSB) was used as a data collection instrument. Analysis included descriptive statistics, bivariate analysis using chi-square and t tests, and logistic regression. Of the 320 women in the targeted age range of 50 to 69 years, 238 (74.4%) had a mammogram as recommended biannually. Being married-de facto, in the 60 to 69 age group, and speaking Cantonese at home were positively associated with women's mammographic screening practice. However, no statistically significant differences in acculturation factors and having a mammogram as recommended were found. In terms of CBCSB score, women who had mammograms as recommended had more positive attitudes toward health checkups and perceived fewer barriers to mammographic screening. Effort should be focused on specific subgroups of Chinese-Australian women in order to fully understand the barriers involved in participating in mammographic screening. Nurses can use the findings from the present study to design culturally sensitive breast cancer screening programs to encourage women's participation in mammography. © 2011 Sigma Theta Tau International.

  12. Early community-based family practice elective positively influences medical students' career considerations--a pre-post-comparison.

    PubMed

    Deutsch, Tobias; Hönigschmid, Petra; Frese, Thomas; Sandholzer, Hagen

    2013-02-21

    Demographic change and recruitment problems in family practice are increasingly threatening an adequate primary care workforce in many countries. Thus, it is important to attract young physicians to the field. The purpose of the present study was to examine the effect of an early community-based 28-h family practice elective with one-to-one mentoring on medical students' consideration of family practice as a career option, their interest in working office-based, and several perceptions with regard to specific aspects of a family physician's work. First- and second-year medical students completed questionnaires before and after a short community-based family practice elective, consisting of a preparatory course and a community-based practical experience with one-to-one mentoring by trained family physicians. We found a significantly higher rate of students favoring family practice as a career option after the elective (32.7% vs. 26.0%, p = 0.039). Furthermore, the ranking of family practice among other considered career options improved (p = 0.002). Considerations to work office-based in the future did not change significantly. Perceptions regarding a family physician's job changed positively with regard to the possibility of long-term doctor-patient relationships and treatment of complex disease patterns. The majority of the students described identification with the respective family physician tutor as a professional role model and an increased interest in the specialty. Our results indicate that a short community-based family practice elective early in medical education may positively influence medical students' considerations of a career in family practice. Furthermore, perceptions regarding the specialty with significant impact on its attractiveness may be positively adjusted. Further research is needed to evaluate the influence of different components of a family practice curriculum on the de facto career decisions of young physicians after graduation.

  13. Obtaining the Optimal Dose in Alcohol Dependence Studies

    PubMed Central

    Wages, Nolan A.; Liu, Lei; O’Quigley, John; Johnson, Bankole A.

    2012-01-01

    In alcohol dependence studies, the treatment effect at different dose levels remains to be ascertained. Establishing this effect would aid us in identifying the best dose that has satisfactory efficacy while minimizing the rate of adverse events. We advocate the use of dose-finding methodology that has been successfully implemented in the cancer and HIV settings to identify the optimal dose in a cost-effective way. Specifically, we describe the continual reassessment method (CRM), an adaptive design proposed for cancer trials to reconcile the needs of dose-finding experiments with the ethical demands of established medical practice. We are applying adaptive designs for identifying the optimal dose of medications for the first time in the context of pharmacotherapy research in alcoholism. We provide an example of a topiramate trial as an illustration of how adaptive designs can be used to locate the optimal dose in alcohol treatment trials. It is believed that the introduction of adaptive design methods will enable the development of medications for the treatment of alcohol dependence to be accelerated. PMID:23189064

  14. Clinical Strategy for Optimal Traditional Chinese Medicine (TCM) Herbal Dose Selection in Disease Therapeutics: Expert Consensus on Classic TCM Herbal Formula Dose Conversion.

    PubMed

    Zha, Lin-Hua; He, Li-Sha; Lian, Feng-Mei; Zhen, Zhong; Ji, Hang-Yu; Xu, Li-Peng; Tong, Xiao-Lin

    2015-01-01

    The clinical therapeutics of traditional Chinese medicine (TCM) constitutes a complicated process which involves theory, diagnosis, and formula prescription with specific herbal dosage. Zhang Zhong-Jing's classic work, Treatise on Febrile and Miscellaneous Diseases, has been influencing TCM practice for almost 2000 years. However, during this extended period of time in Chinese history, the Chinese weight measurement system experienced noticeable changes. This change in the weight measurement system inevitably, and perhaps even negatively, affected TCM herbal dosage determination and treatment outcome. Thus, in modern society, a full understanding of the accuracy of herbal dose selection has a critical importance in the TCM daily practice of delivering the best treatment to the patients suffering from different illnesses. In the 973 Project of the Chinese National Basic Research Program, expert consensus on classic TCM formula dose conversion has been reached based on extensive literature review and discussion on the dose-effect relationship of classic TCM formulas. One "liang" in classic TCM formulas is equivalent to 13.8 g. However, based on many TCM basic and clinical studies of variable herbal formula prescriptions and herbal drug preparations, the rule of one liang equals 13.8 g should be adjusted according to different disease conditions. Recommended by the committee on TCM formula dose-effect relationship of the China Association of Chinese Medicine and the World Federation of Chinese Medicine Societies, the following expert consensus has been reached: (i) One liang converts to 6-9 g for the severely and critically ill patients. (ii) One liang converts to 3-6 g for the patients suffering from chronic diseases. (iii) One liang converts to 1-3 g in preventive medicine. The above conversions should be used as a future TCM practice guideline. Using this recommended guideline should enhance the effectiveness of daily TCM practice.

  15. The advantages of absorbed-dose calibration factors.

    PubMed

    Rogers, D W

    1992-01-01

    A formalism for clinical external beam dosimetry based on use of ion chamber absorbed-dose calibration factors is outlined in the context and notation of the AAPM TG-21 protocol. It is shown that basing clinical dosimetry on absorbed-dose calibration factors ND leads to considerable simplification and reduced uncertainty in dose measurement. In keeping with a protocol which is used in Germany, a quantity kQ is defined which relates an absorbed-dose calibration factor in a beam of quality Q0 to that in a beam of quality Q. For 38 cylindrical ion chambers, two sets of values are presented for ND/NX and Ngas/ND and for kQ for photon beams with beam quality specified by the TPR20(10) ratio. One set is based on TG-21's protocol to allow the new formalism to be used while maintaining equivalence to the TG-21 protocol. To demonstrate the magnitude of the overall error in the TG-21 protocol, the other set uses corrected versions of the TG-21 equations and the more consistent physical data of the IAEA Code of Practice. Comparisons are made to procedures based on air-kerma or exposure calibration factors and it is shown that accuracy and simplicity are gained by avoiding the determination of Ngas from NX. It is also shown that the kQ approach simplifies the use of plastic phantoms in photon beams since kQ values change by less than 0.6% compared to those in water although an overall correction factor of 0.973 is needed to go from absorbed dose in water calibration factors to those in PMMA or polystyrene. Values of kQ calculated using the IAEA Code of Practice are presented but are shown to be anomalous because of the way the effective point of measurement changes for 60Co beams. In photon beams the major difference between the IAEA Code of Practice and the corrected AAPM TG-21 protocol is shown to be the Prepl correction factor. Calculated kQ curves and three parameter equations for them are presented for each wall material and are shown to represent accurately the kQ curve

  16. Kodak EDR2 film for patient skin dose assessment in cardiac catheterization procedures.

    PubMed

    Morrell, R E; Rogers, A T

    2006-07-01

    Patient skin doses were measured using Kodak EDR2 film for 20 coronary angiography (CA) and 32 percutaneous transluminal coronary angioplasty (PTCA) procedures. For CA, all skin doses were well below 1 Gy. However, 23% of PTCA patients received skin doses of 1 Gy or more. Dose-area product (DAP) was also recorded and was found to be an inadequate indicator of maximum skin dose. Practical compliance with ICRP recommendations requires a robust method for skin dosimetry that is more accurate than DAP and is applicable over a wider dose range than EDR2 film.

  17. Benchmarking pediatric cranial CT protocols using a dose tracking software system: a multicenter study.

    PubMed

    De Bondt, Timo; Mulkens, Tom; Zanca, Federica; Pyfferoen, Lotte; Casselman, Jan W; Parizel, Paul M

    2017-02-01

    To benchmark regional standard practice for paediatric cranial CT-procedures in terms of radiation dose and acquisition parameters. Paediatric cranial CT-data were retrospectively collected during a 1-year period, in 3 different hospitals of the same country. A dose tracking system was used to automatically gather information. Dose (CTDI and DLP), scan length, amount of retakes and demographic data were stratified by age and clinical indication; appropriate use of child-specific protocols was assessed. In total, 296 paediatric cranial CT-procedures were collected. Although the median dose of each hospital was below national and international diagnostic reference level (DRL) for all age categories, statistically significant (p-value < 0.001) dose differences among hospitals were observed. The hospital with lowest dose levels showed smallest dose variability and used age-stratified protocols for standardizing paediatric head exams. Erroneous selection of adult protocols for children still occurred, mostly in the oldest age-group. Even though all hospitals complied with national and international DRLs, dose tracking and benchmarking showed that further dose optimization and standardization is possible by using age-stratified protocols for paediatric cranial CT. Moreover, having a dose tracking system revealed that adult protocols are still applied for paediatric CT, a practice that must be avoided. • Significant differences were observed in the delivered dose between age-groups and hospitals. • Using age-adapted scanning protocols gives a nearly linear dose increase. • Sharing dose-data can be a trigger for hospitals to reduce dose levels.

  18. Using Six Sigma to improve once daily gentamicin dosing and therapeutic drug monitoring performance.

    PubMed

    Egan, Sean; Murphy, Philip G; Fennell, Jerome P; Kelly, Sinead; Hickey, Mary; McLean, Carolyn; Pate, Muriel; Kirke, Ciara; Whiriskey, Annette; Wall, Niall; McCullagh, Eddie; Murphy, Joan; Delaney, Tim

    2012-12-01

    Safe, effective therapy with the antimicrobial gentamicin requires good practice in dose selection and monitoring of serum levels. Suboptimal therapy occurs with breakdown in the process of drug dosing, serum blood sampling, laboratory processing and level interpretation. Unintentional underdosing may result. This improvement effort aimed to optimise this process in an academic teaching hospital using Six Sigma process improvement methodology. A multidisciplinary project team was formed. Process measures considered critical to quality were defined, and baseline practice was examined through process mapping and audit. Root cause analysis informed improvement measures. These included a new dosing and monitoring schedule, and standardised assay sampling and drug administration timing which maximised local capabilities. Three iterations of the improvement cycle were conducted over a 24-month period. The attainment of serum level sampling in the required time window improved by 85% (p≤0.0001). A 66% improvement in accuracy of dosing was observed (p≤0.0001). Unnecessary dose omission while awaiting level results and inadvertent disruption to therapy due to dosing and monitoring process breakdown were eliminated. Average daily dose administered increased from 3.39 mg/kg to 4.78 mg/kg/day. Using Six Sigma methodology enhanced gentamicin usage process performance. Local process related factors may adversely affect adherence to practice guidelines for gentamicin, a drug which is complex to use. It is vital to adapt dosing guidance and monitoring requirements so that they are capable of being implemented in the clinical environment as a matter of routine. Improvement may be achieved through a structured localised approach with multidisciplinary stakeholder involvement.

  19. Method for inserting noise in digital mammography to simulate reduction in radiation dose

    NASA Astrophysics Data System (ADS)

    Borges, Lucas R.; de Oliveira, Helder C. R.; Nunes, Polyana F.; Vieira, Marcelo A. C.

    2015-03-01

    The quality of clinical x-ray images is closely related to the radiation dose used in the imaging study. The general principle for selecting the radiation is ALARA ("as low as reasonably achievable"). The practical optimization, however, remains challenging. It is well known that reducing the radiation dose increases the quantum noise, which could compromise the image quality. In order to conduct studies about dose reduction in mammography, it would be necessary to acquire repeated clinical images, from the same patient, with different dose levels. However, such practice would be unethical due to radiation related risks. One solution is to simulate the effects of dose reduction in clinical images. This work proposes a new method, based on the Anscombe transformation, which simulates dose reduction in digital mammography by inserting quantum noise into clinical mammograms acquired with the standard radiation dose. Thus, it is possible to simulate different levels of radiation doses without exposing the patient to new levels of radiation. Results showed that the achieved quality of simulated images generated with our method is the same as when using other methods found in the literature, with the novelty of using the Anscombe transformation for converting signal-independent Gaussian noise into signal-dependent quantum noise.

  20. MO-DE-204-00: International Symposium: Patient Dose Reduction in Diagnostic Radiology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    2016-06-15

    The main topic of the session is to show how dose optimization is being implemented in various regions of the world, including Europe, Australia, North America and other regions. A multi-national study conducted under International Atomic Energy Agency (IAEA) across more than 50 less resourced countries gave insight into patient radiation doses and safety practices in CT, mammography, radiography and interventional procedures, both for children and adults. An important outcome was the capability development on dose assessment and management. An overview of recent European projects related to CT radiation dose and optimization both to adults and children will be presented.more » Existing data on DRLs together with a European methodology proposed on establishing and using DRLs for paediatric radiodiagnostic imaging and interventional radiology practices will be shown. Compared with much of Europe at least, many Australian imaging practices are relatively new to the task of diagnostic imaging dose optimisation. In 2008 the Australian Government prescribed a requirement to periodically compare patient radiation doses with diagnostic reference levels (DRLs), where DRLs have been established. Until recently, Australia had only established DRLs for computed tomography (CT). Regardless, both professional society and individual efforts to improved data collection and develop optimisation strategies across a range of modalities continues. Progress in this field, principally with respect to CT and interventional fluoroscopy will be presented. In the US, dose reduction and optimization efforts for computed tomography have been promoted and mandated by several organizations and accrediting entities. This presentation will cover the general motivation, implementation, and implications of such efforts. Learning Objectives: Understand importance of the dose optimization in Diagnostic Radiology. See how this goal is achieved in different regions of the World. Learn about the

  1. MO-DE-204-02: Optimization of the Patient CT Dose in Europe

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tsapaki, V.

    2016-06-15

    The main topic of the session is to show how dose optimization is being implemented in various regions of the world, including Europe, Australia, North America and other regions. A multi-national study conducted under International Atomic Energy Agency (IAEA) across more than 50 less resourced countries gave insight into patient radiation doses and safety practices in CT, mammography, radiography and interventional procedures, both for children and adults. An important outcome was the capability development on dose assessment and management. An overview of recent European projects related to CT radiation dose and optimization both to adults and children will be presented.more » Existing data on DRLs together with a European methodology proposed on establishing and using DRLs for paediatric radiodiagnostic imaging and interventional radiology practices will be shown. Compared with much of Europe at least, many Australian imaging practices are relatively new to the task of diagnostic imaging dose optimisation. In 2008 the Australian Government prescribed a requirement to periodically compare patient radiation doses with diagnostic reference levels (DRLs), where DRLs have been established. Until recently, Australia had only established DRLs for computed tomography (CT). Regardless, both professional society and individual efforts to improved data collection and develop optimisation strategies across a range of modalities continues. Progress in this field, principally with respect to CT and interventional fluoroscopy will be presented. In the US, dose reduction and optimization efforts for computed tomography have been promoted and mandated by several organizations and accrediting entities. This presentation will cover the general motivation, implementation, and implications of such efforts. Learning Objectives: Understand importance of the dose optimization in Diagnostic Radiology. See how this goal is achieved in different regions of the World. Learn about the

  2. Respirators, internal dose, and Oyster Creek

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Michal, R.

    1996-06-01

    This article looks at the experience of Oyster Creek in relaxing the requirements for the use of respirators in all facets of plant maintenance, on the overall dose received by plant maintenance personnel. For Roger Shaw, director of radiological controls for three years at GPU Nuclear Corporation`s Oyster Creek nuclear plant the correct dose balance is determined on a job-by-job basis: Does the job require a respirator, which is an effective means of decreasing worker inhalation of airborne radioactive particles? Will wearing a respirator slow down a worker, consequently increasing whole body radiation exposure by prolonging the time spent inmore » fields of high external radiation? How does respiratory protection affect worker safety and to what degree? While changes to the Nuclear Regulatory Commission`s 10CFR20 have updated the radiation protection requirements for the nuclear industry, certain of the revisions have been directed specifically at reducing worker dose, Shaw said. {open_quotes}It basically delineates that dose is dose,{close_quotes} Shaw said, {open_quotes}regardless of whether it is acquired externally or internally.{close_quotes} The revision of Part 20 changed the industry`s attitude toward internal dose, which had always been viewed negatively. {open_quotes}Internal dose was always seen as preventable by wearing respirators and by using engineering techniques such as ventilation control and decontamination,{close_quotes} Shaw said, {open_quotes}whereas external dose, although reduced where practical, was seen as a fact of the job.{close_quotes}« less

  3. Dose specification for radiation therapy: dose to water or dose to medium?

    NASA Astrophysics Data System (ADS)

    Ma, C.-M.; Li, Jinsheng

    2011-05-01

    The Monte Carlo method enables accurate dose calculation for radiation therapy treatment planning and has been implemented in some commercial treatment planning systems. Unlike conventional dose calculation algorithms that provide patient dose information in terms of dose to water with variable electron density, the Monte Carlo method calculates the energy deposition in different media and expresses dose to a medium. This paper discusses the differences in dose calculated using water with different electron densities and that calculated for different biological media and the clinical issues on dose specification including dose prescription and plan evaluation using dose to water and dose to medium. We will demonstrate that conventional photon dose calculation algorithms compute doses similar to those simulated by Monte Carlo using water with different electron densities, which are close (<4% differences) to doses to media but significantly different (up to 11%) from doses to water converted from doses to media following American Association of Physicists in Medicine (AAPM) Task Group 105 recommendations. Our results suggest that for consistency with previous radiation therapy experience Monte Carlo photon algorithms report dose to medium for radiotherapy dose prescription, treatment plan evaluation and treatment outcome analysis.

  4. American Society for Radiation Oncology (ASTRO) and American College of Radiology (ACR) Practice Guideline for the Performance of High-Dose-Rate Brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Erickson, Beth A.; Demanes, D. Jeffrey; Ibbott, Geoffrey S.

    2011-03-01

    High-Dose-Rate (HDR) brachytherapy is a safe and efficacious treatment option for patients with a variety of different malignancies. Careful adherence to established standards has been shown to improve the likelihood of procedural success and reduce the incidence of treatment-related morbidity. A collaborative effort of the American College of Radiology (ACR) and American Society for Therapeutic Radiation Oncology (ASTRO) has produced a practice guideline for HDR brachytherapy. The guideline defines the qualifications and responsibilities of all the involved personnel, including the radiation oncologist, physicist and dosimetrists. Review of the leading indications for HDR brachytherapy in the management of gynecologic, thoracic, gastrointestinal,more » breast, urologic, head and neck, and soft tissue tumors is presented. Logistics with respect to the brachytherapy implant procedures and attention to radiation safety procedures and documentation are presented. Adherence to these practice guidelines can be part of ensuring quality and safety in a successful HDR brachytherapy program.« less

  5. Thyroid Dose During Neurointerventional Procedures: Does Lead Shielding Reduce the Dose?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shortt, C. P.; Fanning, N. F.; Malone, L.

    2007-09-15

    Purpose. To assess radiation dose to the thyroid in patients undergoing neurointerventional procedures and to evaluate dose reduction to the thyroid by lead shielding. Methods and Materials. A randomized patient study was undertaken to evaluate the dose reduction by thyroid lead shields and assess their practicality in a clinical setting. Sixty-five patients attending for endovascular treatment of arteriovenous malformations (AVMs) and aneurysms were randomized into one of 2 groups a) No Thyroid Shield and b) Thyroid Lead Shield. Two thermoluminescent dosimeters (TLDs) were placed over the thyroid gland (1 on each side) at constant positions on each patient in bothmore » groups. A thyroid lead shield (Pb eq. 0.5 mm) was placed around the neck of patients in the thyroid lead shield group after the neurointerventional radiologist had obtained satisfactory working access above the neck. The total dose-area-product (DAP) value, number and type of digital subtraction angiography (DSA) runs and fluoroscopy time were recorded for all patients. Results. Of the 72 patients who initially attended for neurointerventional procedures, 7 were excluded due to failure to consent or because of procedures involving access to the external carotid circulation. Of the remaining 65 who were randomized, a further 9 were excluded due to; procedureabandonment, unfeasible shield placement or shield interference with the procedure. Patient demographics included mean age of 47.9 yrs (15-74), F:M=1.4:1. Mean fluoroscopy time was 25.9 min. Mean DAP value was 13,134.8 cGy.cm{sup 2} and mean number of DSA runs was 13.4. The mean relative thyroid doses were significantly different (p< 0.001) between the unshielded (7.23 mSv/cGy2 x 105) and shielded groups (3.77 mSv/cGy2 x 105). A mean thyroid dose reduction of 48% was seen in the shielded group versus the unshielded group. Conclusion. Considerable doses to the thyroid are incurred during neurointerventional procedures, highlighting the need for

  6. Prospective study of inner ear radiation dose and hearing loss in head-and-neck cancer patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pan, Charlie C.; Eisbruch, Avraham; Lee, Julia S.

    Purpose: To determine the relationship between the radiation dose to the inner ear and long-term hearing loss. Methods and Materials: Eligible patients included those receiving curative radiotherapy (RT) for head-and-neck cancer. After enrollment, patients underwent three-dimensional conformal RT planning and delivery (180-200 cGy/fraction) appropriate for their disease site and stage. The inner ear was contoured on axial CT planning images. Dose-volume histograms, as well as the mean and maximal dose for each structure, were calculated. Patients underwent pure tone audiometry at baseline (before treatment) and 1, 6, 12, 24, and 36 months after RT. The threshold level (the greater themore » value, the more hearing loss) in decibels was recorded for 250, 500, 1000, 2000, 4000, and 8000 Hz. For patients receiving predominantly unilateral RT, the contralateral ear served as the de facto control. The differences in threshold level between the ipsilateral and contralateral ears were calculated, and the temporal pattern and dose-response relation of hearing loss were analyzed using statistical methods that take into account the correlation between two ears in the same subject and repeated, sequential measurements of each subject. Results: Of the 40 patients enrolled in this study, 35 qualified for analysis. Four patients who received concurrent chemotherapy and RT were analyzed separately. The 31 unilaterally treated patients received a median dose of 47.4 Gy (range, 14.1-68.8 Gy) to the ipsilateral inner ear and 4.2 Gy (range, 0.5-31.3 Gy) to the contralateral inner ear. Hearing loss was associated with the radiation dose received by the inner ear (loss of 210dB was observed in ears receiving {>=}45 Gy) and was most appreciable in the higher frequencies ({>=}2000 Hz). For a 60-year-old patient with no previous hearing loss in either ear, after receiving 45 Gy, the ipsilateral ear, according to our clinical model, would have a 19.3-dB (95% confidence interval [CI], 15

  7. Recommendation of the Advisory Committee on Immunization Practices for Use of a Third Dose of Mumps Virus-Containing Vaccine in Persons at Increased Risk for Mumps During an Outbreak.

    PubMed

    Marin, Mona; Marlow, Mariel; Moore, Kelly L; Patel, Manisha

    2018-01-12

    A substantial increase in the number of mumps outbreaks and outbreak-associated cases has occurred in the United States since late 2015 (1,2). To address this public health problem, the Advisory Committee on Immunization Practices (ACIP) reviewed the available evidence and determined that a third dose of measles, mumps, rubella (MMR) vaccine is safe and effective at preventing mumps. During its October 2017 meeting, ACIP recommended a third dose of a mumps virus-containing vaccine* for persons previously vaccinated with 2 doses who are identified by public health authorities as being part of a group or population at increased risk for acquiring mumps because of an outbreak. The purpose of the recommendation is to improve protection of persons in outbreak settings against mumps disease and mumps-related complications. This recommendation supplements the existing ACIP recommendations for mumps vaccination (3).

  8. Low-dose aspirin and risk of intracranial bleeds: An observational study in UK general practice.

    PubMed

    Cea Soriano, Lucía; Gaist, David; Soriano-Gabarró, Montse; Bromley, Susan; García Rodríguez, Luis A

    2017-11-28

    To quantify the risk of intracranial bleeds (ICBs) associated with new use of prophylactic low-dose aspirin using a population-based primary care database in the United Kingdom. A cohort of new users of low-dose aspirin (75-300 mg; n = 199,079) aged 40-84 years and a 1:1 matched cohort of nonusers of low-dose aspirin at baseline were followed (maximum 14 years, median 5.4 years) to identify incident cases of ICB, with validation by manual review of patient records or linkage to hospitalization data. Using 10,000 frequency-matched controls, adjusted rate ratios (RRs) with 95% confidence intervals (CIs) were calculated for current low-dose aspirin use (0-7 days before the index date [ICB date for cases, random date for controls]); reference group was never used. There were 1,611 cases of ICB (n = 743 for intracerebral hemorrhage [ICH], n = 483 for subdural hematoma [SDH], and n = 385 for subarachnoid hemorrhage [SAH]). RRs (95% CI) were 0.98 (0.84-1.13) for all ICB, 0.98 (0.80-1.20) for ICH, 1.23 (0.95-1.59) for SDH, and 0.77 (0.58-1.01) for SAH. No duration of use or dose-response association was apparent. RRs (95% CI) for ≥1 year of low-dose aspirin use were 0.90 (0.72-1.13) for ICH, 1.20 (0.91-1.57) for SDH, and 0.69 (0.50-0.94) for SAH. Low-dose aspirin is not associated with an increased risk of any type of ICB and is associated with a significantly decreased risk of SAH when used for ≥1 year. © 2017 American Academy of Neurology.

  9. Methods of space radiation dose analysis with applications to manned space systems

    NASA Technical Reports Server (NTRS)

    Langley, R. W.; Billings, M. P.

    1972-01-01

    The full potential of state-of-the-art space radiation dose analysis for manned missions has not been exploited. Point doses have been overemphasized, and the critical dose to the bone marrow has been only crudely approximated, despite the existence of detailed man models and computer codes for dose integration in complex geometries. The method presented makes it practical to account for the geometrical detail of the astronaut as well as the vehicle. Discussed are the major assumptions involved and the concept of applying the results of detailed proton dose analysis to the real-time interpretation of on-board dosimetric measurements.

  10. SparseCT: interrupted-beam acquisition and sparse reconstruction for radiation dose reduction

    NASA Astrophysics Data System (ADS)

    Koesters, Thomas; Knoll, Florian; Sodickson, Aaron; Sodickson, Daniel K.; Otazo, Ricardo

    2017-03-01

    State-of-the-art low-dose CT methods reduce the x-ray tube current and use iterative reconstruction methods to denoise the resulting images. However, due to compromises between denoising and image quality, only moderate dose reductions up to 30-40% are accepted in clinical practice. An alternative approach is to reduce the number of x-ray projections and use compressed sensing to reconstruct the full-tube-current undersampled data. This idea was recognized in the early days of compressed sensing and proposals for CT dose reduction appeared soon afterwards. However, no practical means of undersampling has yet been demonstrated in the challenging environment of a rapidly rotating CT gantry. In this work, we propose a moving multislit collimator as a practical incoherent undersampling scheme for compressed sensing CT and evaluate its application for radiation dose reduction. The proposed collimator is composed of narrow slits and moves linearly along the slice dimension (z), to interrupt the incident beam in different slices for each x-ray tube angle (θ). The reduced projection dataset is then reconstructed using a sparse approach, where 3D image gradients are employed to enforce sparsity. The effects of the collimator slits on the beam profile were measured and represented as a continuous slice profile. SparseCT was tested using retrospective undersampling and compared against commercial current-reduction techniques on phantoms and in vivo studies. Initial results suggest that SparseCT may enable higher performance than current-reduction, particularly for high dose reduction factors.

  11. Clinical practice variations in prescribing antipsychotics for patients with schizophrenia.

    PubMed

    Owen, Richard R; Fischer, Ellen P; Kirchner, JoAnn E; Thrush, Carol R; Williams, D Keith; Cuffel, Brian J; Elliott, Carl E; Booth, Brenda M

    2003-01-01

    Few studies have examined the variations among individual physicians in prescribing antipsychotics for schizophrenia. This study examined clinical practice variations in the route and dosage of antipsychotic medication prescribed for inpatients with schizophrenia by 11 different psychiatrists. The sample consisted of 130 patients with a DSM-III-R diagnosis of schizophrenia who had received inpatient care at a state hospital or Veterans Affairs medical center in the southeastern United States in 1992-1993. Mixed-effects regression models were developed to explore the influence of individual physicians and hospitals on route of antipsychotic administration (oral or depot) and daily antipsychotic dose, controlling for patient case-mix variables (age, race, sex, duration of illness, symptom severity, and substance-abuse diagnosis). The average daily antipsychotic dose was 1092 +/- 892 chlorpromazine mg equivalents. Almost half of the patients (48%) were prescribed doses above or below the range recommended by current practice guidelines. The proportion of patients prescribed depot antipsychotics was significantly different at the 2 hospitals, as was the antipsychotic dose prescribed at discharge. Individual physicians and patient characteristics were not significantly associated with prescribing practices. These data, which were obtained before clinical practice guidelines were widely disseminated, provide a benchmark against which to examine more current practice variations in antipsychotic prescribing. The results raise several questions about deviations from practice guidelines in the pharmacological treatment of schizophrenia. To adequately assess quality and inform and possibly further develop clinical practice guideline recommendations for schizophrenia, well-designed research studies conducted in routine clinical settings are needed.

  12. Proton dose distribution measurements using a MOSFET detector with a simple dose-weighted correction method for LET effects.

    PubMed

    Kohno, Ryosuke; Hotta, Kenji; Matsuura, Taeko; Matsubara, Kana; Nishioka, Shie; Nishio, Teiji; Kawashima, Mitsuhiko; Ogino, Takashi

    2011-04-04

    We experimentally evaluated the proton beam dose reproducibility, sensitivity, angular dependence and depth-dose relationships for a new Metal Oxide Semiconductor Field Effect Transistor (MOSFET) detector. The detector was fabricated with a thinner oxide layer and was operated at high-bias voltages. In order to accurately measure dose distributions, we developed a practical method for correcting the MOSFET response to proton beams. The detector was tested by examining lateral dose profiles formed by protons passing through an L-shaped bolus. The dose reproducibility, angular dependence and depth-dose response were evaluated using a 190 MeV proton beam. Depth-output curves produced using the MOSFET detectors were compared with results obtained using an ionization chamber (IC). Since accurate measurements of proton dose distribution require correction for LET effects, we developed a simple dose-weighted correction method. The correction factors were determined as a function of proton penetration depth, or residual range. The residual proton range at each measurement point was calculated using the pencil beam algorithm. Lateral measurements in a phantom were obtained for pristine and SOBP beams. The reproducibility of the MOSFET detector was within 2%, and the angular dependence was less than 9%. The detector exhibited a good response at the Bragg peak (0.74 relative to the IC detector). For dose distributions resulting from protons passing through an L-shaped bolus, the corrected MOSFET dose agreed well with the IC results. Absolute proton dosimetry can be performed using MOSFET detectors to a precision of about 3% (1 sigma). A thinner oxide layer thickness improved the LET in proton dosimetry. By employing correction methods for LET dependence, it is possible to measure absolute proton dose using MOSFET detectors.

  13. Knowledge of medical imaging radiation dose and risk among doctors.

    PubMed

    Brown, Nicholas; Jones, Lee

    2013-02-01

    The growth of computed tomography (CT) and nuclear medicine (NM) scans has revolutionised healthcare but also greatly increased population radiation doses. Overuse of diagnostic radiation is becoming a feature of medical practice, leading to possible unnecessary radiation exposures and lifetime-risks of developing cancer. Doctors across all medical specialties and experience levels were surveyed to determine their knowledge of radiation doses and potential risks associated with some diagnostic imaging. A survey relating to knowledge and understanding of medical imaging radiation was distributed to doctors at 14 major Queensland public hospitals, as well as fellows and trainees in radiology, emergency medicine and general practice. From 608 valid responses, only 17.3% correctly estimated the radiation dose from CT scans and almost 1 in 10 incorrectly believed that CT radiation is not associated with any increased lifetime risk of developing cancer. There is a strong inverse relationship between a clinician's experience and their knowledge of CT radiation dose and risks, even among radiologists. More than a third (35.7%) of doctors incorrectly believed that typical NM imaging either does not use ionising radiation or emits doses equal to or less than a standard chest radiograph. Knowledge of CT and NM radiation doses is poor across all specialties, and there is a significant inverse relationship between experience and awareness of CT dose and risk. Despite having a poor understanding of these concepts, most doctors claim to consider them prior to requesting scans and when discussing potential risks with patients. © 2012 The Authors. Journal of Medical Imaging and Radiation Oncology © 2012 The Royal Australian and New Zealand College of Radiologists.

  14. TH-E-209-01: Fluoroscopic Dose Monitoring and Patient Follow-Up Program at Massachusetts General Hospital

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, B.

    2016-06-15

    Radiation dose monitoring solutions have opened up new opportunities for medical physicists to be more involved in modern clinical radiology practices. In particular, with the help of comprehensive radiation dose data, data-driven protocol management and informed case follow up are now feasible. Significant challenges remain however and the problems faced by medical physicists are highly heterogeneous. Imaging systems from multiple vendors and a wide range of vintages co-exist in the same department and employ data communication protocols that are not fully standardized or implemented making harmonization complex. Many different solutions for radiation dose monitoring have been implemented by imaging facilitiesmore » over the past few years. Such systems are based on commercial software, home-grown IT solutions, manual PACS data dumping, etc., and diverse pathways can be used to bring the data to impact clinical practice. The speakers will share their experiences with creating or tailoring radiation dose monitoring/management systems and procedures over the past few years, which vary significantly in design and scope. Topics to cover: (1) fluoroscopic dose monitoring and high radiation event handling from a large academic hospital; (2) dose monitoring and protocol optimization in pediatric radiology; and (3) development of a home-grown IT solution and dose data analysis framework. Learning Objectives: Describe the scope and range of radiation dose monitoring and protocol management in a modern radiology practice Review examples of data available from a variety of systems and how it managed and conveyed. Reflect on the role of the physicist in radiation dose awareness.« less

  15. [Individualization of low-dose oral contraceptives. Pharmacological principles and practical indications for oral contraceptives].

    PubMed

    Cianci, A; De Leo, V

    2007-08-01

    The contraceptive pill has been a revolution of the last 40 years. In Italy, however, it is much less widely used than in other countries. Explanations for this phenomenon range from religious implications and customs to misinformation and word-of-mouth communication of negative experiences. The oral contraceptive pill is often used to correct menstrual disorders, leading to poor results and side-effects. Recent advances in oral contraception have led to a substantial reduction in doses and side-effects. Low-dose pills contain minimal doses of progesterones and estrogens and ensure good control of the menstrual cycle. Although reduction of ethinyl estradiol (EE) concentrations has reduced the incidence of negative systemic side effects such as water retention, edema and swollen breasts, the low estrogen dose may be associated with spotting and hypomenorrhea or amenorrhea in the long term, as well as dyspareunia due to reduced vaginal trophism, which may induce women to suspend use of the drug. It is also true that only one type of estrogen is used in the pill, albeit at different doses, whereas the progesterone may differ and in many cases is the cause of common side-effects. The choice of progesterone therefore involves not only its effect on the endometrium in synergy with estrogen, but also possible residual androgenic activity which may have negative metabolic repercussions. Indeed, addition of a progesterone, especially androgen-derived, attenuates the positive metabolic effects of estrogen. Two new monophasic oral contraceptives were recently released. They contain 30 microg (Yasmin) or 20 muicrog (Yasminelle) EE and a new progesterone, drospirenone, derived from spirolactone, which has antiandrogenic and antimineralcorticoid activity similar to endogenous progesterone. Like progesterone, the drospirenone molecule is an aldosterone antagonist and has a natriuretic effect that opposes the sodium retention effect of EE. It may, therefore, help to prevent the

  16. Estimation of the total effective dose from low-dose CT scans and radiopharmaceutical administrations delivered to patients undergoing SPECT/CT explorations.

    PubMed

    Montes, Carlos; Tamayo, Pilar; Hernandez, Jorge; Gomez-Caminero, Felipe; García, Sofia; Martín, Carlos; Rosero, Angela

    2013-08-01

    Hybrid imaging, such as SPECT/CT, is used in routine clinical practice, allowing coregistered images of the functional and structural information provided by the two imaging modalities. However, this multimodality imaging may mean that patients are exposed to a higher radiation dose than those receiving SPECT alone. The study aimed to determine the radiation exposure of patients who had undergone SPECT/CT examinations and to relate this to the Background Equivalent Radiation Time (BERT). 145 SPECT/CT studies were used to estimate the total effective dose to patients due to both radiopharmaceutical administrations and low-dose CT scans. The CT contribution was estimated by the Dose-Length Product method. Specific conversion coefficients were calculated for SPECT explorations. The radiation dose from low-dose CTs ranged between 0.6 mSv for head and neck CT and 2.6 mSv for whole body CT scan, representing a maximum of 1 year of background radiation exposure. These values represent a decrease of 80-85% with respect to the radiation dose from diagnostic CT. The radiation exposure from radiopharmaceutical administration varied from 2.1 mSv for stress myocardial perfusion SPECT to 26 mSv for gallium SPECT in patients with lymphoma. The BERT ranged from 1 to 11 years. The contribution of low-dose CT scans to the total radiation dose to patients undergoing SPECT/CT examinations is relatively low compared with the effective dose from radiopharmaceutical administration. When a CT scan is only acquired for anatomical localization and attenuation correction, low-dose CT scan is justified on the basis of its lower dose.

  17. Communicating doses of pediatric liquid medicines to parents/caregivers: a comparison of written dosing directions on prescriptions with labels applied by dispensed pharmacy.

    PubMed

    Shah, Rita; Blustein, Leona; Kuffner, Ed; Davis, Lisa

    2014-03-01

    To identify and compare volumetric measures used by healthcare providers in communicating dosing instructions for pediatric liquid prescriptions to parents/caregivers. Dosing instructions were retrospectively reviewed for the 10 most frequently prescribed liquid medications dispensed from 4 community pharmacies for patients aged ≤ 12 years during a 3-month period. Volumetric measures on original prescriptions (ie, milliliters, teaspoons) were compared with those utilized by the pharmacist on the pharmacy label dispensed to the parent/caregiver. Of 649 prescriptions and corresponding pharmacy labels evaluated, 68% of prescriptions and 62% of pharmacy labels communicated dosing in milliliters, 24% of prescriptions and 29% of pharmacy labels communicated dosing in teaspoonfuls, 7% of prescriptions and 0% of pharmacy labels communicated dosing in other measures (ie, milligrams, cubic centimeters, "dose"), and 25% of dispensed pharmacy labels did not reflect units as written in the prescription. Volumetric measures utilized by healthcare professionals in dosing instructions for prescription pediatric oral liquid medications are not consistent. Healthcare professionals and parents/caregivers should be educated on safe dosing practices for liquid pediatric medications. Generalizability to the larger pediatric population may vary depending on pharmacy chain, location, and medications evaluated. Copyright © 2014 Mosby, Inc. All rights reserved.

  18. Evaluation of dose reduction versus standard dosing for maintenance of remission in patients with spondyloarthritis and clinical remission with anti-TNF (REDES-TNF): study protocol for a randomized controlled trial.

    PubMed

    Pontes, Caridad; Gratacós, Jordi; Torres, Ferran; Avendaño, Cristina; Sanz, Jesús; Vallano, Antoni; Juanola, Xavier; de Miguel, Eugenio; Sanmartí, Raimon; Calvo, Gonzalo

    2015-08-20

    Dose reduction schedules of tumor necrosis factor antagonists (anti-TNF) as maintenance therapy in patients with spondyloarthritis are used empirically in clinical practice, despite the lack of clinical trials providing evidence for this practice. To address this issue the Spanish Society of Rheumatology (SER) and Spanish Society of Clinical Pharmacology (SEFC) designed a 3-year multicenter, randomized, open-label, controlled clinical trial (2 years for inclusion and 1 year of follow-up). The study is expected to include 190 patients with axial spondyloarthritis on stable maintenance treatment (≥4 months) with any anti-TNF agent at doses recommended in the summary of product characteristics. Patients will be randomized to either a dose reduction arm or maintenance of the dosing regimen as per the official labelling recommendations. Randomization will be stratified according to the anti-TNF agent received before study inclusion. Patient follow-up, visit schedule, and examinations will be maintained as per normal clinical practice recommendations according to SER guidelines. The study aims to test the hypothesis of noninferiority of the dose reduction strategy compared with standard treatment. The first patients were recruited in July 2012, and study completion is scheduled for the end of April 2015. The REDES-TNF study is a pragmatic clinical trial that aims to provide evidence to support a medical decision now made empirically. The study results may help inform clinical decisions relevant to both patients and healthcare decision makers. EudraCT 2011-005871-18 (21 December 2011).

  19. Dialysis Cannot be Dosed

    PubMed Central

    Meyer, Timothy W.; Sirich, Tammy L.; Hostetter, Thomas H.

    2014-01-01

    Adequate dialysis is difficult to define because we have not identified the toxic solutes that contribute most to uremic illness. Dialysis prescriptions therefore cannot be adjusted to control the levels of these solutes. The current solution to this problem is to define an adequate dose of dialysis on the basis of fraction of urea removed from the body. This has provided a practical guide to treatment as the dialysis population has grown over the past 25 years. Indeed, a lower limit to Kt/Vurea (or the related urea reduction ratio) is now established as a quality indicator by the Centers for Medicare and Medicaid for chronic hemodialysis patients in the United States. For the present, this urea-based standard provides a useful tool to avoid grossly inadequate dialysis. Dialysis dosing, however, based on measurement of a single, relatively nontoxic solute can provide only a very limited guide toward improved treatment. Prescriptions which have similar effects on the index solute can have widely different effects on other solutes. The dose concept discourages attempts to increase the removal of such solutes independent of the index solute. The dose concept further assumes that important solutes are produced at a constant rate relative to body size, and discourages attempts to augment dialysis treatment by reducing solute production. Identification of toxic solutes would provide a more rational basis for the prescription of dialysis and ultimately for improved treatment of patients with renal failure. PMID:21929590

  20. Induction prednisone dosing for childhood nephrotic syndrome: how low should we go?

    PubMed

    Sibley, Matthew; Roshan, Abishek; Alshami, Alanoud; Catapang, Marisa; Jöbsis, Jasper J; Kwok, Trevor; Polderman, Nonnie; Sibley, Jennifer; Matsell, Douglas G; Mammen, Cherry

    2018-05-22

    Historically, children with nephrotic syndrome (NS) across British Columbia (BC), Canada have been cared for without formal standardization of induction prednisone dosing. We hypothesized that local historical practice variation in induction dosing was wide and that children treated with lower doses had worse relapsing outcomes. This retrospective cohort study included 92 NS patients from BC Children's Hospital (1990-2010). We excluded secondary causes of NS, age < 1 year at diagnosis, steroid resistance, and incomplete induction due to early relapse. We explored cumulative induction dose and defined dosing quartiles. Relapsing outcomes above and below each quartile threshold were compared including total relapses in 2 years, time to first relapse, and proportions developing frequently relapsing NS (FRNS) or starting a steroid-sparing agent (SSA). Cumulative prednisone was widely distributed with approximated median, 1st, and 3rd quartile doses of 2500, 2000, and 3000 mg/m 2 respectively. Doses ≤ 2000 mg/m 2 showed significantly higher relapses (4.2 vs 2.7), shorter time to first relapse (61 vs 175 days), and higher SSA use (36 vs 14%) compared to higher doses. Doses ≤ 2500 mg/m 2 also showed significantly more relapses (3.9 vs 2.2), quicker first relapse (79 vs 208 days), and higher FRNS (37 vs 17%) and SSA use (28 vs 11%). Relapsing outcomes lacked statistical difference in ≤ 3000 vs > 3000 mg/m 2 doses. Results strongly justify our development of a standardized, province-wide NS clinical pathway to reduce practice variation and minimize under-treatment. The lowest induction prednisone dosing threshold to minimize future relapsing risks is likely between 2000 and 2500 mg/m 2 . Further prospective studies are warranted.

  1. Absorbed Dose and Dose Equivalent Calculations for Modeling Effective Dose

    NASA Technical Reports Server (NTRS)

    Welton, Andrew; Lee, Kerry

    2010-01-01

    While in orbit, Astronauts are exposed to a much higher dose of ionizing radiation than when on the ground. It is important to model how shielding designs on spacecraft reduce radiation effective dose pre-flight, and determine whether or not a danger to humans is presented. However, in order to calculate effective dose, dose equivalent calculations are needed. Dose equivalent takes into account an absorbed dose of radiation and the biological effectiveness of ionizing radiation. This is important in preventing long-term, stochastic radiation effects in humans spending time in space. Monte carlo simulations run with the particle transport code FLUKA, give absorbed and equivalent dose data for relevant shielding. The shielding geometry used in the dose calculations is a layered slab design, consisting of aluminum, polyethylene, and water. Water is used to simulate the soft tissues that compose the human body. The results obtained will provide information on how the shielding performs with many thicknesses of each material in the slab. This allows them to be directly applicable to modern spacecraft shielding geometries.

  2. Optimizing bevacizumab dosing in glioblastoma: less is more.

    PubMed

    Ajlan, Abdulrazag; Thomas, Piia; Albakr, Abdulrahman; Nagpal, Seema; Recht, Lawrence

    2017-10-01

    Compared to traditional chemotherapies, where dose limiting toxicities represent the maximum possible dose, monoclonal antibody therapies are used at doses well below maximum tolerated dose. However, there has been little effort to ascertain whether there is a submaximal dose at which the efficacy/complication ratio is maximized. Thus, despite the general practice of using Bevacizumab (BEV) at dosages of 10 mg/kg every other week for glioma patients, there has not been much prior work examining whether the relatively high complication rates reported with this agent can be decreased by lowering the dose without impairing efficacy. We assessed charts from 80 patients who received BEV for glioblastoma to survey the incidence of complications relative to BEV dose. All patients were treated with standard upfront chemoradiation. The toxicity was graded based on the NCI CTCAE, version 4.03. The rate of BEV serious related adverse events was 12.5% (n = 10/80). There were no serious adverse events (≥grade 3) when the administered dose was (<3 mg/kg/week), compared to a 21% incidence in those who received higher doses (≥3 mg/kg/week) (P < 0.01). Importantly, the three patient deaths attributable to BEV administration occurred in patients receiving higher doses. Patients who received lower doses also had a better survival rate, although this did not reach statistical significance [median OS 39 for low dose group vs. 17.3 for high dose group (P = 0.07)]. Lower rates of serious BEV related toxicities are noted when lower dosages are used without diminishing positive clinical impact. Further work aimed at optimizing BEV dosage is justified.

  3. Dose equivalent rate constants and barrier transmission data for nuclear medicine facility dose calculations and shielding design.

    PubMed

    Kusano, Maggie; Caldwell, Curtis B

    2014-07-01

    A primary goal of nuclear medicine facility design is to keep public and worker radiation doses As Low As Reasonably Achievable (ALARA). To estimate dose and shielding requirements, one needs to know both the dose equivalent rate constants for soft tissue and barrier transmission factors (TFs) for all radionuclides of interest. Dose equivalent rate constants are most commonly calculated using published air kerma or exposure rate constants, while transmission factors are most commonly calculated using published tenth-value layers (TVLs). Values can be calculated more accurately using the radionuclide's photon emission spectrum and the physical properties of lead, concrete, and/or tissue at these energies. These calculations may be non-trivial due to the polyenergetic nature of the radionuclides used in nuclear medicine. In this paper, the effects of dose equivalent rate constant and transmission factor on nuclear medicine dose and shielding calculations are investigated, and new values based on up-to-date nuclear data and thresholds specific to nuclear medicine are proposed. To facilitate practical use, transmission curves were fitted to the three-parameter Archer equation. Finally, the results of this work were applied to the design of a sample nuclear medicine facility and compared to doses calculated using common methods to investigate the effects of these values on dose estimates and shielding decisions. Dose equivalent rate constants generally agreed well with those derived from the literature with the exception of those from NCRP 124. Depending on the situation, Archer fit TFs could be significantly more accurate than TVL-based TFs. These results were reflected in the sample shielding problem, with unshielded dose estimates agreeing well, with the exception of those based on NCRP 124, and Archer fit TFs providing a more accurate alternative to TVL TFs and a simpler alternative to full spectral-based calculations. The data provided by this paper should assist

  4. Wyoming's Instructional Facilitator Program: Teachers' Beliefs about the Impact of Coaching on Practice

    ERIC Educational Resources Information Center

    Rush, Leslie S.; Young, Suzanne

    2011-01-01

    In 2006, the Wyoming state government allocated monies for the Department of Education to fund the work of Instructional Facilitators, or coaches, in schools across the state (Wyoming Department of Education, 2008). In Spring 2009, after the program had been in place for two years, an ex-post facto study was designed to examine the impact of the…

  5. Neo-Liberalism, Globalization, Language Policy and Practice Issues in the Asia-Pacific Region

    ERIC Educational Resources Information Center

    Majhanovich, Suzanne

    2014-01-01

    By the beginning of the twenty-first century, the English language had become the de facto "lingua franca" of the modern world. It is the most popular second or foreign language studied, such that now there are more people who have learned English as a second language and speak it with some competence than there are native English…

  6. Collaboration and cogenerativity: on bridging the gaps separating theory-practice and cognition-emotion

    NASA Astrophysics Data System (ADS)

    Stetsenko, Anna

    2008-07-01

    In this rejoinder, I comment on how going through the activity of participating in this forum and of engaging in dialogue with my commentators makes sense at several levels—most importantly, at the personal and the conceptual—and how these two levels are intricately connected. The link between the personal and conceptual (cognition and emotion)—their de facto unity—is highlighted through a discussion of a theoretical stance that has to do with ineluctable dialogicality of any and all aspects, incarnations, and expressions of human development, being, and learning. The dialogicality of knowing comes to the fore if knowledge is understood as being part and parcel of ongoing real life activities out in the world imbued with ideology, values, and commitments. In this stance, knowing and acting, words and deeds, theory and practice cannot be ever thought of as separate realms; instead they inevitably and necessarily appear as belonging together and as forming inherent aspects (or dimensions) of one and the same process of people collaboratively engaging with and transforming the world.

  7. Dose tracking and dose auditing in a comprehensive computed tomography dose-reduction program.

    PubMed

    Duong, Phuong-Anh; Little, Brent P

    2014-08-01

    Implementation of a comprehensive computed tomography (CT) radiation dose-reduction program is a complex undertaking, requiring an assessment of baseline doses, an understanding of dose-saving techniques, and an ongoing appraisal of results. We describe the role of dose tracking in planning and executing a dose-reduction program and discuss the use of the American College of Radiology CT Dose Index Registry at our institution. We review the basics of dose-related CT scan parameters, the components of the dose report, and the dose-reduction techniques, showing how an understanding of each technique is important in effective auditing of "outlier" doses identified by dose tracking. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. Evaluation of organ doses and specific k effective dose of 64-slice CT thorax examination using an adult anthropomorphic phantom

    NASA Astrophysics Data System (ADS)

    Hashim, S.; Karim, M. K. A.; Bakar, K. A.; Sabarudin, A.; Chin, A. W.; Saripan, M. I.; Bradley, D. A.

    2016-09-01

    The magnitude of radiation dose in computed tomography (CT) depends on the scan acquisition parameters, investigated herein using an anthropomorphic phantom (RANDO®) and thermoluminescence dosimeters (TLD). Specific interest was in the organ doses resulting from CT thorax examination, the specific k coefficient for effective dose estimation for particular protocols also being determined. For measurement of doses representing five main organs (thyroid, lung, liver, esophagus and skin), TLD-100 (LiF:Mg, Ti) were inserted into selected holes in a phantom slab. Five CT thorax protocols were investigated, one routine (R1) and four that were modified protocols (R2 to R5). Organ doses were ranked from greatest to least, found to lie in the order: thyroid>skin>lung>liver>breast. The greatest dose, for thyroid at 25 mGy, was that in use of R1 while the lowest, at 8.8 mGy, was in breast tissue using R3. Effective dose (E) was estimated using three standard methods: the International Commission on Radiological Protection (ICRP)-103 recommendation (E103), the computational phantom CT-EXPO (E(CTEXPO)) method, and the dose-length product (DLP) based approach. E103 k factors were constant for all protocols, 8% less than that of the universal k factor. Due to inconsistency in tube potential and pitch factor the k factors from CTEXPO were found to vary between 0.015 and 0.010 for protocols R3 and R5. With considerable variation between scan acquisition parameters and organ doses, optimization of practice is necessary in order to reduce patient organ dose.

  9. Institutional experience of interstitial brachytherapy for head and neck cancer with a comparison of high- and low dose rate practice.

    PubMed

    Mohanti, Bidhu Kalyan; Sahai, Puja; Thakar, Alok; Sikka, Kapil; Bhasker, Suman; Sharma, Atul; Sharma, Seema; Bahadur, Sudhir

    2014-01-01

    To describe our institutional experience with high dose rate (HDR) interstitial brachytherapy (IBT) compared with previously reported results on the low dose rate (LDR) practice for head and neck cancer. Eighty-four patients with oral cavity (n=70) or oropharyngeal cancer (n=14) were treated with 192Ir HDR-IBT. Seventy-eight patients had stage I or II tumour. The patients treated with IBT alone (n=42) received 39-42 Gy/10-14 fractions (median=40 Gy/10 fractions). With respect to the combination therapy group (n=42), prescription dose comprised of 12-18 Gy/3-6 fractions (median=15 Gy/5 fractions) for IBT and 40-50 Gy/20-25 fractions (median=50 Gy/25 fractions) for external radiotherapy. Brachytherapy was given as 2 fractions per day 6 hours apart with 4 Gy per fraction for monotherapy and 3 Gy per fraction for combination therapy. Four patients were not evaluable in the analysis of outcome. The primary site relapse rates were 23.8% (10/42) and 68.4% (26/38) in patients treated with IBT alone and combination therapy, respectively (p<0.001). Salvage surgery was performed in 19 patients. The 5-year local control rate was estimated at 62% and the disease-free survival (DFS) rate at 52% for all patients. Local control with respect to T1 and T2 tumours was 84% and 42%, respectively. Our present series on HDR-IBT and the previous report on LDR-IBT for head and neck cancer demonstrated similar DFS rates at 5 years (52%). The rate of regional failure in node-negative patients was <20% in both of our series. HDR-IBT offers similar results to LDR-IBT for head and neck cancer.

  10. Nonclinical dose formulation analysis method validation and sample analysis.

    PubMed

    Whitmire, Monica Lee; Bryan, Peter; Henry, Teresa R; Holbrook, John; Lehmann, Paul; Mollitor, Thomas; Ohorodnik, Susan; Reed, David; Wietgrefe, Holly D

    2010-12-01

    Nonclinical dose formulation analysis methods are used to confirm test article concentration and homogeneity in formulations and determine formulation stability in support of regulated nonclinical studies. There is currently no regulatory guidance for nonclinical dose formulation analysis method validation or sample analysis. Regulatory guidance for the validation of analytical procedures has been developed for drug product/formulation testing; however, verification of the formulation concentrations falls under the framework of GLP regulations (not GMP). The only current related regulatory guidance is the bioanalytical guidance for method validation. The fundamental parameters for bioanalysis and formulation analysis validations that overlap include: recovery, accuracy, precision, specificity, selectivity, carryover, sensitivity, and stability. Divergence in bioanalytical and drug product validations typically center around the acceptance criteria used. As the dose formulation samples are not true "unknowns", the concept of quality control samples that cover the entire range of the standard curve serving as the indication for the confidence in the data generated from the "unknown" study samples may not always be necessary. Also, the standard bioanalytical acceptance criteria may not be directly applicable, especially when the determined concentration does not match the target concentration. This paper attempts to reconcile the different practices being performed in the community and to provide recommendations of best practices and proposed acceptance criteria for nonclinical dose formulation method validation and sample analysis.

  11. Dosing algorithm to target a predefined AUC in patients with primary central nervous system lymphoma receiving high dose methotrexate.

    PubMed

    Joerger, Markus; Ferreri, Andrés J M; Krähenbühl, Stephan; Schellens, Jan H M; Cerny, Thomas; Zucca, Emanuele; Huitema, Alwin D R

    2012-02-01

    There is no consensus regarding optimal dosing of high dose methotrexate (HDMTX) in patients with primary CNS lymphoma. Our aim was to develop a convenient dosing algorithm to target AUC(MTX) in the range between 1000 and 1100 µmol l(-1) h. A population covariate model from a pooled dataset of 131 patients receiving HDMTX was used to simulate concentration-time curves of 10,000 patients and test the efficacy of a dosing algorithm based on 24 h MTX plasma concentrations to target the prespecified AUC(MTX) . These data simulations included interindividual, interoccasion and residual unidentified variability. Patients received a total of four simulated cycles of HDMTX and adjusted MTX dosages were given for cycles two to four. The dosing algorithm proposes MTX dose adaptations ranging from +75% in patients with MTX C(24) < 0.5 µmol l(-1) up to -35% in patients with MTX C(24) > 12 µmol l(-1). The proposed dosing algorithm resulted in a marked improvement of the proportion of patients within the AUC(MTX) target between 1000 and 1100 µmol l(-1) h (11% with standard MTX dose, 35% with the adjusted dose) and a marked reduction of the interindividual variability of MTX exposure. A simple and practical dosing algorithm for HDMTX has been developed based on MTX 24 h plasma concentrations, and its potential efficacy in improving the proportion of patients within a prespecified target AUC(MTX) and reducing the interindividual variability of MTX exposure has been shown by data simulations. The clinical benefit of this dosing algorithm should be assessed in patients with primary central nervous system lymphoma (PCNSL). © 2011 The Authors. British Journal of Clinical Pharmacology © 2011 The British Pharmacological Society.

  12. New image-processing and noise-reduction software reduces radiation dose during complex endovascular procedures.

    PubMed

    Kirkwood, Melissa L; Guild, Jeffrey B; Arbique, Gary M; Tsai, Shirling; Modrall, J Gregory; Anderson, Jon A; Rectenwald, John; Timaran, Carlos

    2016-11-01

    A new proprietary image-processing system known as AlluraClarity, developed by Philips Healthcare (Best, The Netherlands) for radiation-based interventional procedures, claims to lower radiation dose while preserving image quality using noise-reduction algorithms. This study determined whether the surgeon and patient radiation dose during complex endovascular procedures (CEPs) is decreased after the implementation of this new operating system. Radiation dose to operators, procedure type, reference air kerma, kerma area product, and patient body mass index were recorded during CEPs on two Philips Allura FD 20 fluoroscopy systems with and without Clarity. Operator dose during CEPs was measured using optically stimulable, luminescent nanoDot (Landauer Inc, Glenwood, Ill) detectors placed outside the lead apron at the left upper chest position. nanoDots were read using a microStar ii (Landauer Inc) medical dosimetry system. For the CEPs in the Clarity group, the radiation dose to surgeons was also measured by the DoseAware (Philips Healthcare) personal dosimetry system. Side-by-side measurements of DoseAware and nanoDots allowed for cross-calibration between systems. Operator effective dose was determined using a modified Niklason algorithm. To control for patient size and case complexity, the average fluoroscopy dose rate and the dose per radiographic frame were adjusted for body mass index differences and then compared between the groups with and without Clarity by procedure. Additional factors, for example, physician practice patterns, that may have affected operator dose were inferred by comparing the ratio of the operator dose to procedural kerma area product with and without Clarity. A one-sided Wilcoxon rank sum test was used to compare groups for radiation doses, reference air kermas, and operating practices for each procedure type. The analysis included 234 CEPs; 95 performed without Clarity and 139 with Clarity. Practice patterns of operators during

  13. Typical doses and dose rates in studies pertinent to radiation risk inference at low doses and low dose rates

    PubMed Central

    Rühm, Werner; Azizova, Tamara; Bouffler, Simon; Cullings, Harry M; Grosche, Bernd; Little, Mark P; Shore, Roy S; Walsh, Linda; Woloschak, Gayle E

    2018-01-01

    Abstract In order to quantify radiation risks at exposure scenarios relevant for radiation protection, often extrapolation of data obtained at high doses and high dose rates down to low doses and low dose rates is needed. Task Group TG91 on ‘Radiation Risk Inference at Low-dose and Low-dose Rate Exposure for Radiological Protection Purposes’ of the International Commission on Radiological Protection is currently reviewing the relevant cellular, animal and human studies that could be used for that purpose. This paper provides an overview of dose rates and doses typically used or present in those studies, and compares them with doses and dose rates typical of those received by the A-bomb survivors in Japan. PMID:29432579

  14. Ability-Based Criteria and the Lower Class Student: The De Facto Screw.

    ERIC Educational Resources Information Center

    Amato, Josephine; Backman, Carl B.

    Social class discrimination in the schooling process is less a product of teachers' attitudes than of the systems by which schools group students. Although class bias has been demonstrated in grading practices and other key decision points, numerous studies have shown that teachers are less to blame for inequitable learning situations than…

  15. Morphological changes induced by different doses of gamma irradiation in garlic sprouts

    NASA Astrophysics Data System (ADS)

    Pellegrini, C. N.; Croci, C. A.; Orioli, G. A.

    2000-03-01

    The objective of this work was to evaluate the effects of different doses of gamma rays applied in dormancy and post-dormancy on garlic bulbs in relation with some morphophysiological parameters. High (commercial) doses cause the complete inhibition of sprouting and mitosis (due to nuclear aberrations). Relatively low doses show no effects on bulbs but doses of 10 Gy applied in post-dormancy reduce sprouting and stop mitosis. This inhibition becomes noticeable from 150 days post-harvest onwards. Exogenous growth regulators can reverse these effects. Results may reinforce the good practice of radioinhibition processes in garlic.

  16. Development of a web-based CT dose calculator: WAZA-ARI.

    PubMed

    Ban, N; Takahashi, F; Sato, K; Endo, A; Ono, K; Hasegawa, T; Yoshitake, T; Katsunuma, Y; Kai, M

    2011-09-01

    A web-based computed tomography (CT) dose calculation system (WAZA-ARI) is being developed based on the modern techniques for the radiation transport simulation and for software implementation. Dose coefficients were calculated in a voxel-type Japanese adult male phantom (JM phantom), using the Particle and Heavy Ion Transport code System. In the Monte Carlo simulation, the phantom was irradiated with a 5-mm-thick, fan-shaped photon beam rotating in a plane normal to the body axis. The dose coefficients were integrated into the system, which runs as Java servlets within Apache Tomcat. Output of WAZA-ARI for GE LightSpeed 16 was compared with the dose values calculated similarly using MIRD and ICRP Adult Male phantoms. There are some differences due to the phantom configuration, demonstrating the significance of the dose calculation with appropriate phantoms. While the dose coefficients are currently available only for limited CT scanner models and scanning options, WAZA-ARI will be a useful tool in clinical practice when development is finalised.

  17. Over-scanning in chest CT: Comparison of practice among six hospitals and its impact on radiation dose.

    PubMed

    Schwartz, Fides; Stieltjes, Bram; Szucs-Farkas, Zsolt; Euler, André

    2018-05-01

    Compare incidence of over-scanning in chest CT among six hospitals and impact on effective and organ effective radiation dose. Scout images of 600 chest CTs from six hospitals (A-F) were retrospectively reviewed using a radiation dose tracking software (RTS). Optimal scan range was determined and compared to the actual scan range. Incidence of cranial and caudal over-scanning was assessed and changes in total and organ effective dose were calculated. Descriptive statistics, Tukey- and Wilcoxon matched pairs test were applied. Simultaneous cranial and caudal over-scanning occurred in 29 of 600 scans (A = 0%, B = 1%, C = 12%, D = 3%, E = 11%, F = 2%). Effective radiation dose increased on average by 0.29 mSv (P < 0.001). Cranial over-scanning was observed in 45 of 600 scans (A = 0%, B = 8%, C = 2%, D = 15%, E = 17%, F = 3%) and increased organ effective dose by 0.35 mSv in the thyroid gland (P < 0.001). Caudal over-scanning occurred in 147 of 600 scans (A = 7%, B = 9%, C = 35%, D = 4%, E = 32%, F = 60%) and increased organ effective doses in the upper abdomen by up to 14% (P < 0.001 for all organs). Substantial differences in the incidence of over-scanning in chest CT exist among different hospitals. These differences result in excessive effective radiation dose and increased individual organ effective doses in patients. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. Collision-kerma conversion between dose-to-tissue and dose-to-water by photon energy-fluence corrections in low-energy brachytherapy.

    PubMed

    Giménez-Alventosa, Vicent; Antunes, Paula C G; Vijande, Javier; Ballester, Facundo; Pérez-Calatayud, José; Andreo, Pedro

    2017-01-07

    The AAPM TG-43 brachytherapy dosimetry formalism, introduced in 1995, has become a standard for brachytherapy dosimetry worldwide; it implicitly assumes that charged-particle equilibrium (CPE) exists for the determination of absorbed dose to water at different locations, except in the vicinity of the source capsule. Subsequent dosimetry developments, based on Monte Carlo calculations or analytical solutions of transport equations, do not rely on the CPE assumption and determine directly the dose to different tissues. At the time of relating dose to tissue and dose to water, or vice versa, it is usually assumed that the photon fluence in water and in tissues are practically identical, so that the absorbed dose in the two media can be related by their ratio of mass energy-absorption coefficients. In this work, an efficient way to correlate absorbed dose to water and absorbed dose to tissue in brachytherapy calculations at clinically relevant distances for low-energy photon emitting seeds is proposed. A correction is introduced that is based on the ratio of the water-to-tissue photon energy-fluences. State-of-the art Monte Carlo calculations are used to score photon fluence differential in energy in water and in various human tissues (muscle, adipose and bone), which in all cases include a realistic modelling of low-energy brachytherapy sources in order to benchmark the formalism proposed. The energy-fluence based corrections given in this work are able to correlate absorbed dose to tissue and absorbed dose to water with an accuracy better than 0.5% in the most critical cases (e.g. bone tissue).

  19. Collision-kerma conversion between dose-to-tissue and dose-to-water by photon energy-fluence corrections in low-energy brachytherapy

    NASA Astrophysics Data System (ADS)

    Giménez-Alventosa, Vicent; Antunes, Paula C. G.; Vijande, Javier; Ballester, Facundo; Pérez-Calatayud, José; Andreo, Pedro

    2017-01-01

    The AAPM TG-43 brachytherapy dosimetry formalism, introduced in 1995, has become a standard for brachytherapy dosimetry worldwide; it implicitly assumes that charged-particle equilibrium (CPE) exists for the determination of absorbed dose to water at different locations, except in the vicinity of the source capsule. Subsequent dosimetry developments, based on Monte Carlo calculations or analytical solutions of transport equations, do not rely on the CPE assumption and determine directly the dose to different tissues. At the time of relating dose to tissue and dose to water, or vice versa, it is usually assumed that the photon fluence in water and in tissues are practically identical, so that the absorbed dose in the two media can be related by their ratio of mass energy-absorption coefficients. In this work, an efficient way to correlate absorbed dose to water and absorbed dose to tissue in brachytherapy calculations at clinically relevant distances for low-energy photon emitting seeds is proposed. A correction is introduced that is based on the ratio of the water-to-tissue photon energy-fluences. State-of-the art Monte Carlo calculations are used to score photon fluence differential in energy in water and in various human tissues (muscle, adipose and bone), which in all cases include a realistic modelling of low-energy brachytherapy sources in order to benchmark the formalism proposed. The energy-fluence based corrections given in this work are able to correlate absorbed dose to tissue and absorbed dose to water with an accuracy better than 0.5% in the most critical cases (e.g. bone tissue).

  20. WORKER INHALATION DOSE COEFFICIENTS FOR RADIONUCLIDES NOT PREVIOUSLY IDENTIFIED IN ICRP PUBLICATION 68

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McLaughlin, David A; Schwahn, Scott O

    2011-01-01

    While inhalation dose coefficients are provided for about 800 radionuclides in International Commission on Radiological Protection (ICRP) Publication 68, many radionuclides of practical dosimetric interest for facilities such as high-energy proton accelerators are not specifically addressed, nor are organ-specific dose coefficients tabulated. The ICRP Publication 68 methodology is used, along with updated radiological decay data and metabolic data, to identify committed equivalent dose coefficients [hT(50)] and committed effective dose coefficients [e(50)] for radionuclides produced at the Oak Ridge National Laboratory s Spallation Neutron Source.

  1. Low-dose-rate or high-dose-rate brachytherapy in treatment of prostate cancer – between options

    PubMed Central

    2013-01-01

    Purpose Permanent low-dose-rate (LDR-BT) and temporary high-dose-rate (HDR-BT) brachytherapy are competitive techniques for clinically localized prostate radiotherapy. Although a randomized trial will likely never to be conducted comparing these two forms of brachytherapy, a comparative analysis proves useful in understanding some of their intrinsic differences, several of which could be exploited to improve outcomes. The aim of this paper is to look for possible similarities and differences between both brachytherapy modalities. Indications and contraindications for monotherapy and for brachytherapy as a boost to external beam radiation therapy (EBRT) are presented. It is suggested that each of these techniques has attributes that advocates for one or the other. First, they represent the extreme ends of the spectrum with respect to dose rate and fractionation, and therefore have inherently different radiobiological properties. Low-dose-rate brachytherapy has the great advantage of being practically a one-time procedure, and enjoys a long-term follow-up database supporting its excellent outcomes and low morbidity. Low-dose-rate brachytherapy has been a gold standard for prostate brachytherapy in low risk patients since many years. On the other hand, HDR is a fairly invasive procedure requiring several sessions associated with a brief hospital stay. Although lacking in significant long-term data, it possesses the technical advantage of control over its postimplant dosimetry (by modulating the source dwell time and position), which is absent in LDR brachytherapy. This important difference in dosimetric control allows HDR doses to be escalated safely, a flexibility that does not exist for LDR brachytherapy. Conclusions Radiobiological models support the current clinical evidence for equivalent outcomes in localized prostate cancer with either LDR or HDR brachytherapy, using current dose regimens. At present, all available clinical data regarding these two techniques

  2. High-dose neutron detector project update

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Menlove, Howard Olsen; Henzlova, Daniela

    These are the slides for a progress review meeting by the sponsor. This is an update on the high-dose neutron detector project. In summary, improvements in both boron coating and signal amplification have been achieved; improved boron coating materials and procedures have increased efficiency by ~ 30-40% without the corresponding increase in the detector plate area; low dead-time via thin cell design (~ 4 mm gas gaps) and fast amplifiers; prototype PDT 8” pod has been received and testing is in progress; significant improvements in efficiency and stability have been verified; use commercial PDT 10B design and fabrication to obtainmore » a faster path from the research to practical high-dose neutron detector.« less

  3. Evidence-Based Design of Fixed-Dose Combinations: Principles and Application to Pediatric Anti-Tuberculosis Therapy.

    PubMed

    Svensson, Elin M; Yngman, Gunnar; Denti, Paolo; McIlleron, Helen; Kjellsson, Maria C; Karlsson, Mats O

    2018-05-01

    Fixed-dose combination formulations where several drugs are included in one tablet are important for the implementation of many long-term multidrug therapies. The selection of optimal dose ratios and tablet content of a fixed-dose combination and the design of individualized dosing regimens is a complex task, requiring multiple simultaneous considerations. In this work, a methodology for the rational design of a fixed-dose combination was developed and applied to the case of a three-drug pediatric anti-tuberculosis formulation individualized on body weight. The optimization methodology synthesizes information about the intended use population, the pharmacokinetic properties of the drugs, therapeutic targets, and practical constraints. A utility function is included to penalize deviations from the targets; a sequential estimation procedure was developed for stable estimation of break-points for individualized dosing. The suggested optimized pediatric anti-tuberculosis fixed-dose combination was compared with the recently launched World Health Organization-endorsed formulation. The optimized fixed-dose combination included 15, 36, and 16% higher amounts of rifampicin, isoniazid, and pyrazinamide, respectively. The optimized fixed-dose combination is expected to result in overall less deviation from the therapeutic targets based on adult exposure and substantially fewer children with underexposure (below half the target). The development of this design tool can aid the implementation of evidence-based formulations, integrating available knowledge and practical considerations, to optimize drug exposures and thereby treatment outcomes.

  4. A Practical Bayesian Design to Identify the Maximum Tolerated Dose Contour for Drug Combination Trials

    PubMed Central

    Zhang, Liangcai; Yuan, Ying

    2016-01-01

    Drug combination therapy has become the mainstream approach to cancer treatment. One fundamental feature that makes combination trials different from single-agent trials is the existence of the maximum tolerated dose (MTD) contour, i.e., multiple MTDs. As a result, unlike single-agent phase I trials, which aim to find a single MTD, it is often of interest to find the MTD contour for combination trials. We propose a new dose-finding design, the waterfall design, to find the MTD contour for drug combination trials. Taking the divide-and-conquer strategy, the waterfall design divides the task of finding the MTD contour into a sequence of one-dimensional dose-finding processes, known as subtrials. The subtrials are conducted sequentially in a certain order, such that the results of each subtrial will be used to inform the design of subsequent subtrials. Such information borrowing allows the waterfall design to explore the two-dimensional dose space efficiently using a limited sample size, and decreases the chance of overdosing and underdosing patients. To accommodate the consideration that doses on the MTD contour may have very different efficacy or synergistic effects due to drug-drug interaction, we further extend our approach to a phase I/II design with the goal of finding the MTD with the highest efficacy. Simulation studies show that the waterfall design is safer and has higher probability of identifying the true MTD contour than some existing designs. The R package “BOIN” to implement the waterfall design is freely available from CRAN. PMID:27580928

  5. [Evaluation of Organ Dose Estimation from Indices of CT Dose Using Dose Index Registry].

    PubMed

    Iriuchijima, Akiko; Fukushima, Yasuhiro; Ogura, Akio

    Direct measurement of each patient organ dose from computed tomography (CT) is not possible. Most methods to estimate patient organ dose is using Monte Carlo simulation with dedicated software. However, dedicated software is too expensive for small scale hospitals. Not every hospital can estimate organ dose with dedicated software. The purpose of this study was to evaluate the simple method of organ dose estimation using some common indices of CT dose. The Monte Carlo simulation software Radimetrics (Bayer) was used for calculating organ dose and analysis relationship between indices of CT dose and organ dose. Multidetector CT scanners were compared with those from two manufactures (LightSpeed VCT, GE Healthcare; SOMATOM Definition Flash, Siemens Healthcare). Using stored patient data from Radimetrics, the relationships between indices of CT dose and organ dose were indicated as each formula for estimating organ dose. The accuracy of estimation method of organ dose was compared with the results of Monte Carlo simulation using the Bland-Altman plots. In the results, SSDE was the feasible index for estimation organ dose in almost organs because it reflected each patient size. The differences of organ dose between estimation and simulation were within 23%. In conclusion, our estimation method of organ dose using indices of CT dose is convenient for clinical with accuracy.

  6. MO-E-18A-01: Imaging: Best Practices In Pediatric Imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Willis, C; Strauss, K; MacDougall, R

    This imaging educational program will focus on solutions to common pediatric imaging challenges. The speakers will present collective knowledge on best practices in pediatric imaging from their experience at dedicated children's hospitals. Areas of focus will include general radiography, the use of manual and automatic dose management in computed tomography, and enterprise-wide radiation dose management in the pediatric practice. The educational program will begin with a discussion of the complexities of exposure factor control in pediatric projection radiography. Following this introduction will be two lectures addressing the challenges of computed tomography (CT) protocol optimization in the pediatric population. The firstmore » will address manual CT protocol design in order to establish a managed radiation dose for any pediatric exam on any CT scanner. The second CT lecture will focus on the intricacies of automatic dose modulation in pediatric imaging with an emphasis on getting reliable results in algorithmbased technique selection. The fourth and final lecture will address the key elements needed to developing a comprehensive radiation dose management program for the pediatric environment with particular attention paid to new regulations and obligations of practicing medical physicists. Learning Objectives: To understand how general radiographic techniques can be optimized using exposure indices in order to improve pediatric radiography. To learn how to establish diagnostic dose reference levels for pediatric patients as a function of the type of examination, patient size, and individual design characteristics of the CT scanner. To learn how to predict the patient's radiation dose prior to the exam and manually adjust technique factors if necessary to match the patient's dose to the department's established dose reference levels. To learn how to utilize manufacturer-provided automatic dose modulation technology to consistently achieve patient doses within

  7. Convolution-based estimation of organ dose in tube current modulated CT

    NASA Astrophysics Data System (ADS)

    Tian, Xiaoyu; Segars, W. Paul; Dixon, Robert L.; Samei, Ehsan

    2016-05-01

    Estimating organ dose for clinical patients requires accurate modeling of the patient anatomy and the dose field of the CT exam. The modeling of patient anatomy can be achieved using a library of representative computational phantoms (Samei et al 2014 Pediatr. Radiol. 44 460-7). The modeling of the dose field can be challenging for CT exams performed with a tube current modulation (TCM) technique. The purpose of this work was to effectively model the dose field for TCM exams using a convolution-based method. A framework was further proposed for prospective and retrospective organ dose estimation in clinical practice. The study included 60 adult patients (age range: 18-70 years, weight range: 60-180 kg). Patient-specific computational phantoms were generated based on patient CT image datasets. A previously validated Monte Carlo simulation program was used to model a clinical CT scanner (SOMATOM Definition Flash, Siemens Healthcare, Forchheim, Germany). A practical strategy was developed to achieve real-time organ dose estimation for a given clinical patient. CTDIvol-normalized organ dose coefficients ({{h}\\text{Organ}} ) under constant tube current were estimated and modeled as a function of patient size. Each clinical patient in the library was optimally matched to another computational phantom to obtain a representation of organ location/distribution. The patient organ distribution was convolved with a dose distribution profile to generate {{≤ft(\\text{CTD}{{\\text{I}}\\text{vol}}\\right)}\\text{organ, \\text{convolution}}} values that quantified the regional dose field for each organ. The organ dose was estimated by multiplying {{≤ft(\\text{CTD}{{\\text{I}}\\text{vol}}\\right)}\\text{organ, \\text{convolution}}} with the organ dose coefficients ({{h}\\text{Organ}} ). To validate the accuracy of this dose estimation technique, the organ dose of the original clinical patient was estimated using Monte Carlo program with TCM profiles explicitly modeled. The

  8. Optimization of equivalent uniform dose using the L-curve criterion.

    PubMed

    Chvetsov, Alexei V; Dempsey, James F; Palta, Jatinder R

    2007-10-07

    Optimization of equivalent uniform dose (EUD) in inverse planning for intensity-modulated radiation therapy (IMRT) prevents variation in radiobiological effect between different radiotherapy treatment plans, which is due to variation in the pattern of dose nonuniformity. For instance, the survival fraction of clonogens would be consistent with the prescription when the optimized EUD is equal to the prescribed EUD. One of the problems in the practical implementation of this approach is that the spatial dose distribution in EUD-based inverse planning would be underdetermined because an unlimited number of nonuniform dose distributions can be computed for a prescribed value of EUD. Together with ill-posedness of the underlying integral equation, this may significantly increase the dose nonuniformity. To optimize EUD and keep dose nonuniformity within reasonable limits, we implemented into an EUD-based objective function an additional criterion which ensures the smoothness of beam intensity functions. This approach is similar to the variational regularization technique which was previously studied for the dose-based least-squares optimization. We show that the variational regularization together with the L-curve criterion for the regularization parameter can significantly reduce dose nonuniformity in EUD-based inverse planning.

  9. Rotation of Boar Semen Doses During Storage Affects Sperm Quality.

    PubMed

    Schulze, M; Rüdiger, K; Waberski, D

    2015-08-01

    It is common practice to rotate boar semen doses during storage for prevention of sperm sedimentation. In this study, the effect of rotation of boar semen doses during storage on sperm quality was investigated. Manual turning twice daily and automatic rotation five times per hour resulted in the following effects: alkalinization of the BTS-extender, loss of membrane integrity at day 3, and loss of motility and changes in sperm kinematics during a thermoresistance test at day 5. Using a pH-stabilized variant of BTS extender, sperm motility and velocity decreased in continuously rotated samples, whereas membrane integrity and mitochondrial activity remain unaffected. It is concluded that rotation of semen samples adversely affects sperm quality and, therefore, should no longer be recommended for AI practice. © 2015 Blackwell Verlag GmbH.

  10. Reference Levels for Patient Radiation Doses in Interventional Radiology: Proposed Initial Values for U.S. Practice1

    PubMed Central

    Miller, Donald L.; Kwon, Deukwoo; Bonavia, Grant H.

    2009-01-01

    Purpose: To propose initial values for patient reference levels for fluoroscopically guided procedures in the United States. Materials and Methods: This secondary analysis of data from the Radiation Doses in Interventional Radiology Procedures (RAD-IR) study was conducted under a protocol approved by the institutional review board and was HIPAA compliant. Dose distributions (percentiles) were calculated for each type of procedure in the RAD-IR study where there were data from at least 30 cases. Confidence intervals for the dose distributions were determined by using bootstrap resampling. Weight banding and size correction methods for normalizing dose to patient body habitus were tested. Results: The different methods for normalizing patient radiation dose according to patient weight gave results that were not significantly different (P > .05). The 75th percentile patient radiation doses normalized with weight banding were not significantly different from those that were uncorrected for body habitus. Proposed initial reference levels for various interventional procedures are provided for reference air kerma, kerma-area product, fluoroscopy time, and number of images. Conclusion: Sufficient data exist to permit an initial proposal of values for reference levels for interventional radiologic procedures in the United States. For ease of use, reference levels without correction for body habitus are recommended. A national registry of radiation-dose data for interventional radiologic procedures is a necessary next step to refine these reference levels. © RSNA, 2009 Supplemental material: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.2533090354/-/DC1 PMID:19789226

  11. History of dose specification in Brachytherapy: From Threshold Erythema Dose to Computational Dosimetry

    NASA Astrophysics Data System (ADS)

    Williamson, Jeffrey F.

    2006-09-01

    This paper briefly reviews the evolution of brachytherapy dosimetry from 1900 to the present. Dosimetric practices in brachytherapy fall into three distinct eras: During the era of biological dosimetry (1900-1938), radium pioneers could only specify Ra-226 and Rn-222 implants in terms of the mass of radium encapsulated within the implanted sources. Due to the high energy of its emitted gamma rays and the long range of its secondary electrons in air, free-air chambers could not be used to quantify the output of Ra-226 sources in terms of exposure. Biological dosimetry, most prominently the threshold erythema dose, gained currency as a means of intercomparing radium treatments with exposure-calibrated orthovoltage x-ray units. The classical dosimetry era (1940-1980) began with successful exposure standardization of Ra-226 sources by Bragg-Gray cavity chambers. Classical dose-computation algorithms, based upon 1-D buildup factor measurements and point-source superposition computational algorithms, were able to accommodate artificial radionuclides such as Co-60, Ir-192, and Cs-137. The quantitative dosimetry era (1980- ) arose in response to the increasing utilization of low energy K-capture radionuclides such as I-125 and Pd-103 for which classical approaches could not be expected to estimate accurate correct doses. This led to intensive development of both experimental (largely TLD-100 dosimetry) and Monte Carlo dosimetry techniques along with more accurate air-kerma strength standards. As a result of extensive benchmarking and intercomparison of these different methods, single-seed low-energy radionuclide dose distributions are now known with a total uncertainty of 3%-5%.

  12. Practical applications of surface analytic tools in tribology

    NASA Technical Reports Server (NTRS)

    Ferrante, J.

    1980-01-01

    Many of the currently, widely used tools available for surface analysis are described. Those which have the highest applicability for giving elemental and/or compound analysis for problems of interest in tribology and are truly surface sensitive (that is, less than 10 atomic layers) are presented. The latter group is evaluated in detail in terms of strengths and weaknesses. Emphasis is placed on post facto analysis of experiments performed under 'real' conditions (e.g., in air with lubricants). It is further indicated that such equipment could be used for screening and quality control.

  13. Low-dose right unilateral electroconvulsive therapy (ECT): effectiveness of the first treatment.

    PubMed

    Lapidus, Kyle A B; Shin, Joseph S W; Pasculli, Rosa M; Briggs, Mimi C; Popeo, Dennis M; Kellner, Charles H

    2013-06-01

    Electroconvulsive therapy (ECT) is a widely used, highly effective antidepressant treatment. Except for the most severely ill patients, right unilateral (RUL) electrode placement is the most frequent initial treatment choice. In current practice, RUL ECT is administered at several multiples of seizure threshold (ST) based on reports that lower stimulus intensity results in lower response/remission rates. Many patients, as part of an initial dose titration to determine ST, will receive a single treatment with low-dose RUL ECT and subsequent treatments with a stimulus at a multiple of ST. To assess response to the first ECT. A retrospective analysis of charts from clinical practice at Mount Sinai Medical Center was performed. A single treatment with low-dose (presumably near ST) RUL ECT had a significant and immediate antidepressant effect in our sample of patients with major depression. We determined that this response is similar to that of patients receiving a single initial treatment with high-dose RUL ECT (at a multiple of ST). These data suggest, contrary to commonly held belief, that RUL ECT may be effective at a low stimulus dose. This argues against restimulating at 6 times ST in the initial session, based on the belief that the near-threshold seizure has no antidepressant efficacy. Our findings suggest a need for further investigation of cases in which low-dose RUL ECT may be an effective antidepressant treatment. Further prospective studies, including larger numbers of patients who receive randomized treatment with low- or high-dose RUL with longer follow-up, are indicated.

  14. Chernobyl doses. Volume 1. Analysis of forest canopy radiation response from multispectral imagery and the relationship to doses. Technical report, 29 July 1987-30 September 1993

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McClennan, G.E.; Anno, G.H.; Whicker, F.W.

    1994-09-01

    This volume of the report Chernobyl Doses presents details of a new, quantitative method for remotely sensing ionizing radiation dose to vegetation. Analysis of Landsat imagery of the area within a few kilometers of the Chernobyl nuclear reactor station provides maps of radiation dose to pine forest canopy resulting from the accident of April 26, 1986. Detection of the first date of significant, persistent deviation from normal of the spectral reflectance signature of pine foliage produces contours of radiation dose in the 20 to 80 Gy range extending up to 4 km from the site of the reactor explosion. Themore » effective duration of exposure for the pine foliage is about 3 weeks. For this exposure time, the LD50 of Pinus sylvestris (Scotch pine) is about 23 Gy. The practical lower dose limit for the remote detection of radiation dose to pine foliage with the Landsat Thematic Mapper is about 5 Gy or 1/4 of the LD50.« less

  15. Is hepatitis B birth dose vaccine needed in Africa?

    PubMed

    Tamandjou, Cynthia Raissa; Maponga, Tongai Gibson; Chotun, Nafiisah; Preiser, Wolfgang; Andersson, Monique Ingrid

    2017-01-01

    This commentary describes the need for a birth dose monovalent hepatitis B virus (HBV) vaccine and an effective programme for the prevention of mother-to-child-transmission (MTCT) of HBV in Africa. Current World Health Organization guidelines recommend routine maternal screening for HBV followed by treatment of highly infectious HBV-infected mothers, and HBV birth dose vaccination and the administration of hepatitis B immunoglobulin for HBV-exposed infants as an effective strategy for the prevention of HBV MTCT. None of these practices are currently in place in most parts of Africa. To date, fewer than 10 African countries vaccinate children at birth against HBV. Despite the hurdles associated with implementing this practice, its expansion to the rest of Africa is feasible and crucial to reducing the global number of new HBV infections by 90% by 2030, as targeted by the current Global Health Strategy for the elimination of viral hepatitis.

  16. Prediction of standard-dose brain PET image by using MRI and low-dose brain [18F]FDG PET images.

    PubMed

    Kang, Jiayin; Gao, Yaozong; Shi, Feng; Lalush, David S; Lin, Weili; Shen, Dinggang

    2015-09-01

    Positron emission tomography (PET) is a nuclear medical imaging technology that produces 3D images reflecting tissue metabolic activity in human body. PET has been widely used in various clinical applications, such as in diagnosis of brain disorders. High-quality PET images play an essential role in diagnosing brain diseases/disorders. In practice, in order to obtain high-quality PET images, a standard-dose radionuclide (tracer) needs to be used and injected into a living body. As a result, it will inevitably increase the patient's exposure to radiation. One solution to solve this problem is predicting standard-dose PET images using low-dose PET images. As yet, no previous studies with this approach have been reported. Accordingly, in this paper, the authors propose a regression forest based framework for predicting a standard-dose brain [(18)F]FDG PET image by using a low-dose brain [(18)F]FDG PET image and its corresponding magnetic resonance imaging (MRI) image. The authors employ a regression forest for predicting the standard-dose brain [(18)F]FDG PET image by low-dose brain [(18)F]FDG PET and MRI images. Specifically, the proposed method consists of two main steps. First, based on the segmented brain tissues (i.e., cerebrospinal fluid, gray matter, and white matter) in the MRI image, the authors extract features for each patch in the brain image from both low-dose PET and MRI images to build tissue-specific models that can be used to initially predict standard-dose brain [(18)F]FDG PET images. Second, an iterative refinement strategy, via estimating the predicted image difference, is used to further improve the prediction accuracy. The authors evaluated their algorithm on a brain dataset, consisting of 11 subjects with MRI, low-dose PET, and standard-dose PET images, using leave-one-out cross-validations. The proposed algorithm gives promising results with well-estimated standard-dose brain [(18)F]FDG PET image and substantially enhanced image quality of low-dose

  17. Prediction of standard-dose brain PET image by using MRI and low-dose brain [18F]FDG PET images

    PubMed Central

    Kang, Jiayin; Gao, Yaozong; Shi, Feng; Lalush, David S.; Lin, Weili; Shen, Dinggang

    2015-01-01

    Purpose: Positron emission tomography (PET) is a nuclear medical imaging technology that produces 3D images reflecting tissue metabolic activity in human body. PET has been widely used in various clinical applications, such as in diagnosis of brain disorders. High-quality PET images play an essential role in diagnosing brain diseases/disorders. In practice, in order to obtain high-quality PET images, a standard-dose radionuclide (tracer) needs to be used and injected into a living body. As a result, it will inevitably increase the patient’s exposure to radiation. One solution to solve this problem is predicting standard-dose PET images using low-dose PET images. As yet, no previous studies with this approach have been reported. Accordingly, in this paper, the authors propose a regression forest based framework for predicting a standard-dose brain [18F]FDG PET image by using a low-dose brain [18F]FDG PET image and its corresponding magnetic resonance imaging (MRI) image. Methods: The authors employ a regression forest for predicting the standard-dose brain [18F]FDG PET image by low-dose brain [18F]FDG PET and MRI images. Specifically, the proposed method consists of two main steps. First, based on the segmented brain tissues (i.e., cerebrospinal fluid, gray matter, and white matter) in the MRI image, the authors extract features for each patch in the brain image from both low-dose PET and MRI images to build tissue-specific models that can be used to initially predict standard-dose brain [18F]FDG PET images. Second, an iterative refinement strategy, via estimating the predicted image difference, is used to further improve the prediction accuracy. Results: The authors evaluated their algorithm on a brain dataset, consisting of 11 subjects with MRI, low-dose PET, and standard-dose PET images, using leave-one-out cross-validations. The proposed algorithm gives promising results with well-estimated standard-dose brain [18F]FDG PET image and substantially enhanced

  18. Nuclear Cardiology Practice in Asia: Analysis of Radiation Exposure and Best Practice for Myocardial Perfusion Imaging - Results From the IAEA Nuclear Cardiology Protocols Cross-Sectional Study (INCAPS).

    PubMed

    Pascual, Thomas N B; Mercuri, Mathew; El-Haj, Noura; Bom, Henry Hee-Sung; Lele, Vikram; Al-Mallah, Mouaz H; Luxenburg, Osnat; Karthikeyan, Ganesan; Vitola, Joao; Mahmarian, John J; Better, Nathan; Shaw, Leslee J; Rehani, Madan M; Kashyap, Ravi; Paez, Diana; Dondi, Maurizio; Einstein, Andrew J

    2017-03-24

    This paper examines the current status of radiation exposure to patients in myocardial perfusion imaging (MPI) in Asia.Methods and Results:Laboratories voluntarily provided information on MPI performed over a 1-week period. Eight best practice criteria regarding MPI were predefined by an expert panel. Implementation of ≥6 best practices (quality index [QI] ≥6) was pre-specified as a desirable goal for keeping radiation exposure at a low level. Radiation effective dose (ED) in 1,469 patients and QI of 69 laboratories in Asia were compared against data from 239 laboratories in the rest of the world (RoW). Mean ED was significantly higher in Asia (11.4 vs. 9.6 mSv; P<0.0001), with significantly lower doses in South-East vs. East Asia (9.7 vs. 12.7 mSv; P<0.0001). QI in Asia was lower than in RoW. In comparison with RoW, Asian laboratories used thallium more frequently, used weight-based technetium dosing less frequently, and trended towards a lower rate of stress-only imaging. MPI radiation dose in Asia is higher than that in the RoW and linked to less consistent use of laboratory best practices such as avoidance of thallium, weight-based dosing, and use of stress-only imaging. Given that MPI is performed in Asia within a diverse array of medical contexts, laboratory-specific adoption of best practices offers numerous opportunities to improve quality of care.

  19. The Management of Patients with Chronic Subdural Hematoma Treated with Low-Dose Acetylsalicylic Acid: An International Survey of Practice.

    PubMed

    Soleman, Jehuda; Kamenova, Maria; Guzman, Raphael; Mariani, Luigi

    2017-11-01

    The aim of this international survey was to investigate the current management of patients undergoing surgery for chronic subdural hematoma (cSDH) treated with low-dose acetylsalicylic acid (ASA). We administered a survey via e-mail to neurosurgeons with questions relating to the surgical treatment of cSDH, emphasizing their practices with patients treated with low-dose ASA. We received 157 responses, with a response rate of 22.4%. Almost 80% of the responders discontinue ASA treatment at least 5 days before surgery and 80.7% resume treatment after 5 days or more, and 27.6% discontinue treatment for at least 30 days. The main factor influencing ASA resumption time is the indication for ASA (54.5%), and postoperative imaging is concluded in 71.7%, Postoperative thrombosis prophylaxis is administered by 60% of the responders, and 50% apply it 24 hours after surgery. Almost 95% of the responders believe that better evidence is needed for the management of patients with cSDH treated with ASA. Guidelines for these patients exist in only 24.3% of the institutes. Most neurosurgeons discontinue ASA treatment for at least 7 days in the perioperative period of surgical evacuation of cSDH, even though recent studies show that early ASA resumption might be safe. Thrombosis prophylaxis is administered by only 60%, even though patients with cSDH are at high risk of developing thromboembolic complications. Better evidence and guidelines are warranted because the incidence of patients with cSDH under the treatment of ASA is increasing. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Reconstruction of paediatric organ doses from axial CT scans performed in the 1990s - range of doses as input to uncertainty estimates.

    PubMed

    Olerud, Hilde M; Toft, Benthe; Flatabø, Silje; Jahnen, Andreas; Lee, Choonsik; Thierry-Chef, Isabelle

    2016-09-01

    To assess the range of doses in paediatric CT scans conducted in the 1990s in Norway as input to an international epidemiology study: the EPI-CT study, http://epi-ct.iarc.fr/ . National Cancer Institute dosimetry system for Computed Tomography (NCICT) program based on pre-calculated organ dose conversion coefficients was used to convert CT Dose Index to organ doses in paediatric CT in the 1990s. Protocols reported from local hospitals in a previous Norwegian CT survey were used as input, presuming these were used without optimization for paediatric patients. Large variations in doses between different scanner models and local scan parameter settings are demonstrated. Small children will receive a factor of 2-3 times higher doses compared with adults if the protocols are not optimized for them. For common CT examinations, the doses to the active bone marrow, breast tissue and brain may have exceeded 30 mGy, 60 mGy and 100 mGy respectively, for the youngest children in the 1990s. The doses children received from non-optimised CT examinations during the 1990s are of such magnitude that they may provide statistically significant effects in the EPI-CT study, but probably do not reflect current practice. • Some organ doses from paediatric CT in the 1990s may have exceeded 100 mGy. • Small children may have received doses 2-3 times higher compared with adults. • Different scanner models varied by a factor of 2-3 in dose to patients. • Different local scan parameter settings gave dose variations of a factor 2-3. • Modern CTs and age-adjusted protocols will give much lower paediatric doses.

  1. Employing the therapeutic operating characteristic (TOC) graph for individualised dose prescription.

    PubMed

    Hoffmann, Aswin L; Huizenga, Henk; Kaanders, Johannes H A M

    2013-03-07

    In current practice, patients scheduled for radiotherapy are treated according to 'rigid' protocols with predefined dose prescriptions that do not consider risk-taking preferences of individuals. The therapeutic operating characteristic (TOC) graph is applied as a decision-aid to assess the trade-off between treatment benefit and morbidity to facilitate dose prescription customisation. Historical dose-response data from prostate cancer patient cohorts treated with 3D-conformal radiotherapy is used to construct TOC graphs. Next, intensity-modulated (IMRT) plans are generated by optimisation based on dosimetric criteria and dose-response relationships. TOC graphs are constructed for dose-scaling of the optimised IMRT plan and individualised dose prescription. The area under the TOC curve (AUC) is estimated to measure the therapeutic power of these plans. On a continuous scale, the TOC graph directly visualises treatment benefit and morbidity risk of physicians' or patients' choices for dose (de-)escalation. The trade-off between these probabilities facilitates the selection of an individualised dose prescription. TOC graphs show broader therapeutic window and higher AUCs with increasing target dose heterogeneity. The TOC graph gives patients and physicians access to a decision-aid and read-out of the trade-off between treatment benefit and morbidity risks for individualised dose prescription customisation over a continuous range of dose levels.

  2. Energy weighting improves dose efficiency in clinical practice: implementation on a spectral photon-counting mammography system

    PubMed Central

    Berglund, Johan; Johansson, Henrik; Lundqvist, Mats; Cederström, Björn; Fredenberg, Erik

    2014-01-01

    Abstract. In x-ray imaging, contrast information content varies with photon energy. It is, therefore, possible to improve image quality by weighting photons according to energy. We have implemented and evaluated so-called energy weighting on a commercially available spectral photon-counting mammography system. The technique was evaluated using computer simulations, phantom experiments, and analysis of screening mammograms. The CNR benefit of energy weighting for a number of relevant target-background combinations measured by the three methods fell in the range of 2.2 to 5.2% when using optimal weight factors. This translates to a potential dose reduction at constant CNR in the range of 4.5 to 11%. We expect the choice of weight factor in practical implementations to be straightforward because (1) the CNR improvement was not very sensitive to weight, (2) the optimal weight was similar for all investigated target-background combinations, (3) aluminum/PMMA phantoms were found to represent clinically relevant tasks well, and (4) the optimal weight could be calculated directly from pixel values in phantom images. Reasonable agreement was found between the simulations and phantom measurements. Manual measurements on microcalcifications and automatic image analysis confirmed that the CNR improvement was detectable in energy-weighted screening mammograms. PMID:26158045

  3. Review of Prescribing Practices for Intermittent Bolus Administration of Morphine

    PubMed Central

    Sine, Keith; Vaillancourt, Régis; Pascuet, Elena; Martelli, Brenda; Lamontagne, Christine; Ellis, Jacqueline; Wong, Elaine; Gaboury, Isabelle

    2011-01-01

    Background: Several changes to medication safety practices were proposed in a pediatric hospital, including changing the period of patient observation after administration of opioids and limiting the availability of various concentrations of morphine in the patient care unit. Objective: To document and review postoperative pain management for children on a surgical ward, specifically with regard to intermittent IV bolus administration of morphine, to help in assessing the impact of the proposed nursing practice changes. Methods: Data were collected from records for narcotics and controlled drugs for the surgical ward over a 3-month period (April to June 2006). For each patient, data had been recorded for up to 7 consecutive days after surgery. A patient’s data were included in the review if he or she had received at least 2 doses of morphine by IV bolus, except for the review of weight-based dosing pattern (mg/kg), for which all patients who had received at least one dose of IV morphine were included. Results: Charts for 193 patients were audited. Of these, 163 patients (84.5%) had recieved up to 0.1 mg/kg per dose, and 53 (27.5%) had received only one dose of morphine. Among patients who received more than one dose, the median dose was 0.080 mg/kg on day 1, with a decrease by day 5 to 0.065 mg/kg. Most patients received morphine over the first 2 days after surgery. The median time elapsed between doses was 4.3 h on day 1 and 6.2 h on day 2. Of the 1020 doses included in the analysis, most (801 [78.5%]) were 4 mg or less. Conclusion: The intermittent administration of IV bolus doses of morphine at the study hospital followed common standards for the treatment of postoperative pain. Most doses were no more than 4 mg. On the basis of this information, only 2-mg vials of morphine are now stocked on the ward. The hospital’s change in monitoring practices will increase the surveillance of patients receiving IV bolus doses of morphine. PMID:22479025

  4. Dashboard systems: Pharmacokinetic/pharmacodynamic mediated dose optimization for monoclonal antibodies.

    PubMed

    Mould, Diane R; Dubinsky, Marla C

    2015-03-01

    Many marketed drugs exhibit high variability in exposure and response. While these drugs are efficacious in their approved indications, finding appropriate dose regimens for individual patients is not straightforward. Similar dose adjustment problems are also seen with drugs that have a complex relationship between exposure and response and/or a narrow therapeutic window. This is particularly true for monoclonal antibodies, where prolonged dosing at a sub-therapeutic dose can also elicit anti-drug antibodies which will further compromise safety and efficacy. Thus, finding appropriate doses quickly would represent a substantial improvement in healthcare. Dashboard systems, which are decision-support tools, offer an improved, convenient means of tailoring treatment for individual patients. This article reviews the clinical need for this approach, particularly with monoclonal antibodies, the design, development, and testing of such systems, and the likely benefits of dashboard systems in clinical practice. We focus on infliximab for reference. © 2015, The American College of Clinical Pharmacology.

  5. Radiation exposure and safety practices during pediatric central line placement

    PubMed Central

    Saeman, Melody R.; Burkhalter, Lorrie S.; Blackburn, Timothy J.; Murphy, Joseph T.

    2015-01-01

    Purpose Pediatric surgeons routinely use fluoroscopy for central venous line (CVL) placement. We examined radiation safety practices and patient/surgeon exposure during fluoroscopic CVL. Methods Fluoroscopic CVL procedures performed by 11 pediatric surgeons in 2012 were reviewed. Fluoroscopic time (FT), patient exposure (mGy), and procedural data were collected. Anthropomorphic phantom simulations were used to calculate scatter and dose (mSv). Surgeons were surveyed regarding safety practices. Results 386 procedures were reviewed. Median FT was 12.8 seconds. Median patient estimated effective dose was 0.13 mSv. Median annual FT per surgeon was 15.4 minutes. Simulations showed no significant difference (p = 0.14) between reported exposures (median 3.5 mGy/min) and the modeled regression exposures from the C-arm default mode (median 3.4 mGy/min). Median calculated surgeon exposure was 1.5 mGy/year. Eight of 11 surgeons responded to the survey. Only three reported 100% lead protection and frequent dosimeter use. Conclusion We found non-standard radiation training, safety practices, and dose monitoring for the 11 surgeons. Based on simulations, the C-arm default setting was typically used instead of low dose. While most CVL procedures have low patient/surgeon doses, every effort should be used to minimize patient and occupational exposure, suggesting the need for formal hands-on training for non-radiologist providers using fluoroscopy. PMID:25837269

  6. Increasing Use of Dose-Escalated External Beam Radiation Therapy for Men With Nonmetastatic Prostate Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Swisher-McClure, Samuel, E-mail: Swisher-Mcclure@uphs.upenn.edu; Leonard Davis Institute of Health Economics, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, PA; Mitra, Nandita

    Purpose: To examine recent practice patterns, using a large national cancer registry, to understand the extent to which dose-escalated external beam radiation therapy (EBRT) has been incorporated into routine clinical practice for men with prostate cancer. Methods and Materials: We conducted a retrospective observational cohort study using the National Cancer Data Base, a nationwide oncology outcomes database in the United States. We identified 98,755 men diagnosed with nonmetastatic prostate cancer between 2006 and 2011 who received definitive EBRT and classified patients into National Comprehensive Cancer Network (NCCN) risk groups. We defined dose-escalated EBRT as total prescribed dose of ≥75.6 Gy. Usingmore » multivariable logistic regression, we examined the association of patient, clinical, and demographic characteristics with the use of dose-escalated EBRT. Results: Overall, 81.6% of men received dose-escalated EBRT during the study period. The use of dose-escalated EBRT did not vary substantially by NCCN risk group. Use of dose-escalated EBRT increased from 70.7% of patients receiving treatment in 2006 to 89.8% of patients receiving treatment in 2011. On multivariable analysis, year of diagnosis and use of intensity modulated radiation therapy were significantly associated with receipt of dose-escalated EBRT. Conclusions: Our study results indicate that dose-escalated EBRT has been widely adopted by radiation oncologists treating prostate cancer in the United States. The proportion of patients receiving dose-escalated EBRT increased nearly 20% between 2006 and 2011. We observed high utilization rates of dose-escalated EBRT within all disease risk groups. Adoption of intensity modulated radiation therapy was strongly associated with use of dose-escalated treatment.« less

  7. Exclusionary Discipline and the Forfeiture of Special Education Rights: A Survey.

    ERIC Educational Resources Information Center

    King, Ashley Thomas

    1996-01-01

    A survey of exclusionary discipline practices with handicapped students revealed a national pattern of "de facto" differential treatment. In denying a school's unilateral authority to remove dangerous or disruptive students, the Supreme Court's judgment in "Honig v. Doe" (1988) took precedence over all earlier court decisions.…

  8. Challenges in validating the sterilisation dose for processed human amniotic membranes

    NASA Astrophysics Data System (ADS)

    Yusof, Norimah; Hassan, Asnah; Firdaus Abd Rahman, M. N.; Hamid, Suzina A.

    2007-11-01

    Most of the tissue banks in the Asia Pacific region have been using ionising radiation at 25 kGy to sterilise human tissues for save clinical usage. Under tissue banking quality system, any dose employed for sterilisation has to be validated and the validation exercise has to be a part of quality document. Tissue grafts, unlike medical items, are not produced in large number per each processing batch and tissues relatively have a different microbial population. A Code of Practice established by the International Atomic Energy Agency (IAEA) in 2004 offers several validation methods using smaller number of samples compared to ISO 11137 (1995), which is meant for medical products. The methods emphasise on bioburden determination, followed by sterility test on samples after they were exposed to verification dose for attaining of sterility assurance level (SAL) of 10 -1. This paper describes our experience in using the IAEA Code of Practice in conducting the validation exercise for substantiating 25 kGy as sterilisation dose for both air-dried amnion and those preserved in 99% glycerol.

  9. The Dose Response Relationship for Radiation Carcinogenesis

    NASA Astrophysics Data System (ADS)

    Hall, Eric

    2008-03-01

    Recent surveys show that the collective population radiation dose from medical procedures in the U.S. has increased by 750% in the past two decades. It would be impossible to imagine the practice of medicine today without diagnostic and therapeutic radiology, but nevertheless the widespread and rapidly increasing use of a modality which is a known human carcinogen is a cause for concern. To assess the magnitude of the problem it is necessary to establish the shape of the dose response relationship for radiation carcinogenesis. Information on radiation carcinogenesis comes from the A-bomb survivors, from occupationally exposed individuals and from radiotherapy patients. The A-bomb survivor data indicates a linear relationship between dose and the risk of solid cancers up to a dose of about 2.5 Sv. The lowest dose at which there is a significant excess cancer risk is debatable, but it would appear to be between 40 and 100 mSv. Data from the occupation exposure of nuclear workers shows an excess cancer risk at an average dose of 19.4 mSv. At the other end of the dose scale, data on second cancers in radiotherapy patients indicates that cancer risk does not continue to rise as a linear function of dose, but tends towards a plateau of 40 to 60 Gy, delivered in a fractionated regime. These data can be used to estimate the impact of diagnostic radiology at the low dose end of the dose response relationship, and the impact of new radiotherapy modalities at the high end of the dose response relationship. In the case of diagnostic radiology about 90% of the collective population dose comes from procedures (principally CT scans) which involve doses at which there is credible evidence of an excess cancer incidence. While the risk to the individual is small and justified in a symptomatic patient, the same is not true of some screening procedures is asymptomatic individuals, and in any case the huge number of procedures must add up to a potential public health problem. In the

  10. Dose Trends of Aripiprazole from 2004 to 2014 in Psychiatric Inpatients in Korea.

    PubMed

    Woo, Young Sup; Shim, In Hee; Lee, Sang-Yeol; Lee, Dae-Bo; Kim, Moon-Doo; Jung, Young-Eun; Lee, Jonghun; Won, Seunghee; Jon, Duk-In; Bahk, Won-Myong

    2017-05-31

    Although aripiprazole has been widely used to treat various psychiatric disorders, little is known about the adequate dosage for Asian patients in clinical practice. Hence, we evaluated the initial and maximum doses of aripiprazole from 2004 to 2014 to estimate the appropriate dosage for Korean psychiatric inpatients in clinical practice. In this retrospective study, we reviewed the medical records of patients who were hospitalized in five university hospitals in Korea from March 2004 to December 2014. The psychiatric diagnosis according to the text revision of the Diagnostic and Statistical Manual of Mental Disorders, 4th edition during index hospitalization and the initial and maximum doses of aripiprazole were evaluated. There were 74 patients in Wave 1 (2004-2006), 201 patients in Wave 2 (2007-2010), and 353 patients in Wave 3 (2011-2014). The initial doses of aripiprazole in all diagnostic groups were significantly lower in Wave 3 than in Wave 2. The maximum doses of aripiprazole in each diagnostic group were not significantly different among Waves 1, 2, and 3. The relatively low initial doses of aripiprazole documented in our study may reflect a strategy by clinicians to minimize the side effects associated with aripiprazole use, such as akathisia.

  11. High-Dose Opioid Prescribing and Opioid-Related Hospitalization: A Population-Based Study.

    PubMed

    Fernandes, Kimberly; Martins, Diana; Juurlink, David; Mamdani, Muhammad; Paterson, J Michael; Spooner, Luke; Singh, Samantha; Gomes, Tara

    2016-01-01

    To examine the impact of national clinical practice guidelines and provincial drug policy interventions on prevalence of high-dose opioid prescribing and rates of hospitalization for opioid toxicity. Interventional time-series analysis. Ontario, Canada, from 2003 to 2014. Ontario Drug Benefit (ODB) beneficiaries aged 15 to 64 years from 2003 to 2014. Publication of Canadian clinical practice guidelines for use of opioids in chronic non-cancer pain (May 2010) and implementation of Ontario's Narcotics Safety and Awareness Act (NSAA; November 2011). Three outcomes were explored: the rate of opioid use among ODB beneficiaries, the prevalence of opioid prescriptions exceeding 200 mg and 400 mg morphine equivalents per day, and rates of opioid-related emergency department visits and hospital admissions. Over the 12 year study period, the rate of opioid use declined 15.2%, from 2764 to 2342 users per 10,000 ODB eligible persons. The rate of opioid use was significantly impacted by the Canadian clinical practice guidelines (p-value = .03) which led to a decline in use, but no impact was observed by the enactment of the NSAA (p-value = .43). Among opioid users, the prevalence of high-dose prescribing doubled (from 4.2% to 8.7%) over the study period. By 2014, 40.9% of recipients of long-acting opioids exceeded daily doses of 200 mg morphine or equivalent, including 55.8% of long-acting oxycodone users and 76.3% of transdermal fentanyl users. Moreover, in the last period, 18.7% of long-acting opioid users exceeded daily doses of 400 mg morphine or equivalent. Rates of opioid-related emergency department visits and hospital admissions increased 55.0% over the study period from 9.0 to 14.0 per 10,000 ODB beneficiaries from 2003 to 2013. This rate was not significantly impacted by the Canadian clinical practice guidelines (p-value = .68) or enactment of the NSAA (p-value = .59). Although the Canadian clinical practice guidelines for use of opioids in chronic non-cancer pain led

  12. [Radiation exposure of radiologists during angiography: dose measurements outside the lead apron].

    PubMed

    Fischer, H; Przetak, C; Teubert, G; Ewen, K; Mödder, U

    1995-02-01

    The aim of this study was to provide practical information to angiographers concerning radiation exposure to body parts not covered by lead aprons. Individual doses to the neck and hands of radiologists measured in micro-Sieverts were obtained during the course of 80 angiographies of various types. The number of diagnostic and interventional procedures, which might lead to exceeding permissible doses, have been calculated. Possibilities of estimating doses during angiography by means of parameters such as screening times were examined statistically. Especially with regard to the hands, estimations of the doses are insufficient (correlation r = 0.21). Radiologists who undertake much angiographic and particularly interventional work may reach exposure levels requiring protective measures in addition to lead aprons.

  13. Comparison of the therapeutic dose of warfarin in HIV-infected and HIV-uninfected patients: a study of clinical practice

    PubMed Central

    Jackson, B S; Mokoena, T

    2017-01-01

    Background People infected with HIV are prone to venous thrombosis. Treatment of thrombosis is primarily with warfarin. No studies have addressed the effects of HIV infection on warfarin dose. The aims of this study were to determine whether the therapeutic dose of warfarin and induction time to therapeutic dose in HIV-infected patients differ from that in HIV-uninfected patients. Methods A prospective and retrospective descriptive study of induction time to therapeutic warfarin dose, as well as of ambulant therapeutic warfarin dose, was performed. HIV-infected and HIV-uninfected patients being treated after deep venous thrombosis with or without pulmonary embolism were compared. Sex and use of antiretroviral drugs (ARVs) were also compared in the groups. Results 234 patients were entered into the study. Induction time to therapeutic warfarin dose did not differ between the 2 groups. The mean therapeutic dose of warfarin was higher in the HIV-infected than the HIV-uninfected group: 6.06 vs 5.72 mg/day, but this was not statistically significant (p=0.29). There was no difference in therapeutic warfarin dose between ARV-naïve groups—HIV-uninfected and HIV-infected patients not on ARVs. Conclusions There appears to be little effect of HIV infection on warfarin dosing. Warfarin therapy should be administered conventionally in HIV-infected patients. PMID:28179414

  14. SU-E-T-248: An Extended Generalized Equivalent Uniform Dose Accounting for Dose-Range Dependency of Radio-Biological Parameters.

    PubMed

    Troeller, A; Soehn, M; Yan, D

    2012-06-01

    Introducing an extended, phenomenological, generalized equivalent uniform dose (eEUD) that incorporates multiple volume-effect parameters for different dose-ranges. The generalized EUD (gEUD) was introduced as an estimate of the EUD that incorporates a single, tissue-specific parameter - the volume-effect-parameter (VEP) 'a'. As a purely phenomenological concept, its radio-biological equivalency to a given inhomogeneous dose distribution is not a priori clear and mechanistic models based on radio-biological parameters are assumed to better resemble the underlying biology. However, for normal organs mechanistic models are hard to derive, since the structural organization of the tissue plays a significant role. Consequently, phenomenological approaches might be especially useful in order to describe dose-response for normal tissues. However, the single parameter used to estimate the gEUD may not suffice in accurately representing more complex biological effects that have been discussed in the literature. For instance, radio-biological parameters and hence the effects of fractionation are known to be dose-range dependent. Therefore, we propose an extended phenomenological eEUD formula that incorporates multiple VEPs accounting for dose-range dependency. The eEUD introduced is a piecewise polynomial expansion of the gEUD formula. In general, it allows for an arbitrary number of VEPs, each valid for a certain dose-range. We proved that the formula fulfills required mathematical and physical criteria such as invertibility of the underlying dose-effect and continuity in dose. Furthermore, it contains the gEUD as a special case, if all VEPs are equal to 'a' from the gEUD model. The eEUD is a concept that expands the gEUD such that it can theoretically represent dose-range dependent effects. Its practicality, however, remains to be shown. As a next step, this will be done by estimating the eEUD from patient data using maximum-likelihood based NTCP modelling in the same way

  15. [Clinical evaluation of heavy-particle radiotherapy using dose volume histogram (DVH)].

    PubMed

    Terahara, A; Nakano, T; Tsujii, H

    1998-01-01

    Radiotherapy with heavy particles such as proton and heavy-charged particles is a promising modality for treatment of localized malignant tumors because of the good dose distribution. A dose calculation and radiotherapy planning system which is essential for this kind of treatment has been developed in recent years. It has the capability to compute the dose volume histogram (DVH) which contains dose-volume information for the target volume and other interesting volumes. Recently, DVH is commonly used to evaluate and compare dose distributions in radiotherapy with both photon and heavy particles, and it shows that a superior dose distribution is obtained in heavy particle radiotherapy. DVH is also utilized for the evaluation of dose distribution related to clinical outcomes. Besides models such as normal tissue complication probability (NTCP) and tumor control probability (TCP), which can be calculated from DVH are proposed by several authors, they are applied to evaluate dose distributions themselves and to evaluate them in relation to clinical results. DVH is now a useful and important tool, but further studies are needed to use DVH and these models practically for clinical evaluation of heavy-particle radiotherapy.

  16. Physics-aspects of dose accuracy in high dose rate (HDR) brachytherapy: source dosimetry, treatment planning, equipment performance and in vivo verification techniques

    PubMed Central

    Bradley, David; Nisbet, Andrew

    2012-01-01

    This study provides a review of recent publications on the physics-aspects of dosimetric accuracy in high dose rate (HDR) brachytherapy. The discussion of accuracy is primarily concerned with uncertainties, but methods to improve dose conformation to the prescribed intended dose distribution are also noted. The main aim of the paper is to review current practical techniques and methods employed for HDR brachytherapy dosimetry. This includes work on the determination of dose rate fields around brachytherapy sources, the capability of treatment planning systems, the performance of treatment units and methods to verify dose delivery. This work highlights the determinants of accuracy in HDR dosimetry and treatment delivery and presents a selection of papers, focusing on articles from the last five years, to reflect active areas of research and development. Apart from Monte Carlo modelling of source dosimetry, there is no clear consensus on the optimum techniques to be used to assure dosimetric accuracy through all the processes involved in HDR brachytherapy treatment. With the exception of the ESTRO mailed dosimetry service, there is little dosimetric audit activity reported in the literature, when compared with external beam radiotherapy verification. PMID:23349649

  17. Software Development for Estimating the Conversion Factor (K-Factor) at Suitable Scan Areas, Relating the Dose Length Product to the Effective Dose.

    PubMed

    Kobayashi, Masanao; Asada, Yasuki; Matsubara, Kosuke; Suzuki, Syouichi; Koshida, Kichiro; Matsunaga, Yuta; Kawaguchi, Ai; Haba, Tomonobu; Toyama, Hiroshi; Kato, Ryouichi

    2017-05-01

    We developed a k-factor-creator software (kFC) that provides the k-factor for CT examination in an arbitrary scan area. It provides the k-factor from the effective dose and dose-length product by Imaging Performance Assessment of CT scanners and CT-EXPO. To assess the reliability, we compared the kFC-evaluated k-factors with those of the International Commission on Radiological Protection (ICRP) publication 102. To confirm the utility, the effective dose determined by coronary computed tomographic angiography (CCTA) was evaluated by a phantom study and k-factor studies. In the CCTA, the effective doses were 5.28 mSv in the phantom study, 2.57 mSv (51%) in the k-factor of ICRP, and 5.26 mSv (1%) in the k-factor of the kFC. Effective doses can be determined from the kFC-evaluated k-factors in suitable scan areas. Therefore, we speculate that the flexible k-factor is useful in clinical practice, because CT examinations are performed in various scan regions. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  18. Physics-aspects of dose accuracy in high dose rate (HDR) brachytherapy: source dosimetry, treatment planning, equipment performance and in vivo verification techniques.

    PubMed

    Palmer, Antony; Bradley, David; Nisbet, Andrew

    2012-06-01

    This study provides a review of recent publications on the physics-aspects of dosimetric accuracy in high dose rate (HDR) brachytherapy. The discussion of accuracy is primarily concerned with uncertainties, but methods to improve dose conformation to the prescribed intended dose distribution are also noted. The main aim of the paper is to review current practical techniques and methods employed for HDR brachytherapy dosimetry. This includes work on the determination of dose rate fields around brachytherapy sources, the capability of treatment planning systems, the performance of treatment units and methods to verify dose delivery. This work highlights the determinants of accuracy in HDR dosimetry and treatment delivery and presents a selection of papers, focusing on articles from the last five years, to reflect active areas of research and development. Apart from Monte Carlo modelling of source dosimetry, there is no clear consensus on the optimum techniques to be used to assure dosimetric accuracy through all the processes involved in HDR brachytherapy treatment. With the exception of the ESTRO mailed dosimetry service, there is little dosimetric audit activity reported in the literature, when compared with external beam radiotherapy verification.

  19. Automatic patient dose registry and clinical audit on line for mammography.

    PubMed

    Ten, J I; Vano, E; Sánchez, R; Fernandez-Soto, J M

    2015-07-01

    The use of automatic registry systems for patient dose in digital mammography allows clinical audit and patient dose analysis of the whole sample of individual mammography exposures while fulfilling the requirements of the European Directives and other international recommendations. Further parameters associated with radiation exposure (tube voltage, X-ray tube output and HVL values for different kVp and target/filter combinations, breast compression, etc.) should be periodically verified and used to evaluate patient doses. This study presents an experience in routine clinical practice for mammography using automatic systems. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  20. Employing the therapeutic operating characteristic (TOC) graph for individualised dose prescription

    PubMed Central

    2013-01-01

    Background In current practice, patients scheduled for radiotherapy are treated according to ‘rigid’ protocols with predefined dose prescriptions that do not consider risk-taking preferences of individuals. The therapeutic operating characteristic (TOC) graph is applied as a decision-aid to assess the trade-off between treatment benefit and morbidity to facilitate dose prescription customisation. Methods Historical dose-response data from prostate cancer patient cohorts treated with 3D-conformal radiotherapy is used to construct TOC graphs. Next, intensity-modulated (IMRT) plans are generated by optimisation based on dosimetric criteria and dose-response relationships. TOC graphs are constructed for dose-scaling of the optimised IMRT plan and individualised dose prescription. The area under the TOC curve (AUC) is estimated to measure the therapeutic power of these plans. Results On a continuous scale, the TOC graph directly visualises treatment benefit and morbidity risk of physicians’ or patients’ choices for dose (de-)escalation. The trade-off between these probabilities facilitates the selection of an individualised dose prescription. TOC graphs show broader therapeutic window and higher AUCs with increasing target dose heterogeneity. Conclusions The TOC graph gives patients and physicians access to a decision-aid and read-out of the trade-off between treatment benefit and morbidity risks for individualised dose prescription customisation over a continuous range of dose levels. PMID:23497640

  1. 47 CFR 1.9003 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Authority § 1.9003 Definitions. De facto transfer leasing arrangement. A spectrum leasing arrangement in which a licensee retains de jure control of its license while transferring de facto control of the... electronically or manually. Long-term de facto transfer leasing arrangement. A long-term de facto transfer...

  2. Comparison of the therapeutic dose of warfarin in HIV-infected and HIV-uninfected patients: a study of clinical practice.

    PubMed

    Jackson, B S; Mokoena, T

    2017-02-08

    People infected with HIV are prone to venous thrombosis. Treatment of thrombosis is primarily with warfarin. No studies have addressed the effects of HIV infection on warfarin dose. The aims of this study were to determine whether the therapeutic dose of warfarin and induction time to therapeutic dose in HIV-infected patients differ from that in HIV-uninfected patients. A prospective and retrospective descriptive study of induction time to therapeutic warfarin dose, as well as of ambulant therapeutic warfarin dose, was performed. HIV-infected and HIV-uninfected patients being treated after deep venous thrombosis with or without pulmonary embolism were compared. Sex and use of antiretroviral drugs (ARVs) were also compared in the groups. 234 patients were entered into the study. Induction time to therapeutic warfarin dose did not differ between the 2 groups. The mean therapeutic dose of warfarin was higher in the HIV-infected than the HIV-uninfected group: 6.06 vs 5.72 mg/day, but this was not statistically significant (p=0.29). There was no difference in therapeutic warfarin dose between ARV-naïve groups-HIV-uninfected and HIV-infected patients not on ARVs. There appears to be little effect of HIV infection on warfarin dosing. Warfarin therapy should be administered conventionally in HIV-infected patients. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  3. Dosing antiretroviral medication when crossing time zones: a review

    PubMed Central

    Lewis, Joseph M.; Volny-Anne, Alain; Waitt, Catriona; Boffito, Marta; Khoo, Saye

    2016-01-01

    International tourism continues to increase worldwide, and people living with HIV and their clinicians are increasingly confronted with the problem of how to dose antiretroviral therapy during transmeridian air travel across time zones. No guidance on this topic currently exists. This review is a response to requests from patient groups for clear, practical and evidence-based guidance for travelling on antiretroviral therapy; we present currently available data on the pharmacokinetic forgiveness and toxicity of various antiretroviral regimens, and synthesize this data to provide guidelines on how to safely dose antiretrovirals when travelling across time zones. PMID:26684823

  4. Personalized versus standardized dosing strategies for the treatment of childhood amblyopia: study protocol for a randomized controlled trial.

    PubMed

    Moseley, Merrick J; Wallace, Michael P; Stephens, David A; Fielder, Alistair R; Smith, Laura C; Stewart, Catherine E

    2015-04-25

    Amblyopia is the commonest visual disorder of childhood in Western societies, affecting, predominantly, spatial visual function. Treatment typically requires a period of refractive correction ('optical treatment') followed by occlusion: covering the nonamblyopic eye with a fabric patch for varying daily durations. Recent studies have provided insight into the optimal amount of patching ('dose'), leading to the adoption of standardized dosing strategies, which, though an advance on previous ad-hoc regimens, take little account of individual patient characteristics. This trial compares the effectiveness of a standardized dosing strategy (that is, a fixed daily occlusion dose based on disease severity) with a personalized dosing strategy (derived from known treatment dose-response functions), in which an initially prescribed occlusion dose is modulated, in a systematic manner, dependent on treatment compliance. A total of 120 children aged between 3 and 8 years of age diagnosed with amblyopia in association with either anisometropia or strabismus, or both, will be randomized to receive either a standardized or a personalized occlusion dose regimen. To avoid confounding by the known benefits of refractive correction, participants will not be randomized until they have completed an optical treatment phase. The primary study objective is to determine whether, at trial endpoint, participants receiving a personalized dosing strategy require fewer hours of occlusion than those in receipt of a standardized dosing strategy. Secondary objectives are to quantify the relationship between observed changes in visual acuity (logMAR, logarithm of the Minimum Angle of Resolution) with age, amblyopia type, and severity of amblyopic visual acuity deficit. This is the first randomized controlled trial of occlusion therapy for amblyopia to compare a treatment arm representative of current best practice with an arm representative of an entirely novel treatment regimen based on statistical

  5. Practical applications of surface analytic tools in tribology

    NASA Technical Reports Server (NTRS)

    Ferrante, J.

    1980-01-01

    A brief description of many of the widely used tools is presented. Of this list, those which have the highest applicability for giving elemental and/or compound analysis for problems of interest in tribology along with being truly surface sensitive (that is less than 10 atomic layers) are presented. The latter group is critiqued in detail in terms of strengths and weaknesses. Emphasis is placed on post facto analysis of experiments performed under real conditions (e.g., in air with lubricants). It is further indicated that such equipment could be used for screening and quality control.

  6. Radiation Dose-Response Relationships and Risk Assessment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Strom, Daniel J.

    The notion of a dose-response relationship was probably invented shortly after the discovery of poisons, the invention of alcoholic beverages, and the bringing of fire into a confined space in the forgotten depths of ancient prehistory. The amount of poison or medicine ingested can easily be observed to affect the behavior, health, or sickness outcome. Threshold effects, such as death, could be easily understood for intoxicants, medicine, and poisons. As Paracelsus (1493-1541), the 'father' of modern toxicology said, 'It is the dose that makes the poison.' Perhaps less obvious is the fact that implicit in such dose-response relationships is alsomore » the notion of dose rate. Usually, the dose is administered fairly acutely, in a single injection, pill, or swallow; a few puffs on a pipe; or a meal of eating or drinking. The same amount of intoxicants, medicine, or poisons administered over a week or month might have little or no observable effect. Thus, before the discovery of ionizing radiation in the late 19th century, toxicology ('the science of poisons') and pharmacology had deeply ingrained notions of dose-response relationships. This chapter demonstrates that the notion of a dose-response relationship for ionizing radiation is hopelessly simplistic from a scientific standpoint. While useful from a policy or regulatory standpoint, dose-response relationships cannot possibly convey enough information to describe the problem from a quantitative view of radiation biology, nor can they address societal values. Three sections of this chapter address the concepts, observations, and theories that contribute to the scientific input to the practice of managing risks from exposure to ionizing radiation. The presentation begins with irradiation regimes, followed by responses to high and low doses of ionizing radiation, and a discussion of how all of this can inform radiation risk management. The knowledge that is really needed for prediction of individual risk is

  7. A systematic review of the use of dosage form manipulation to obtain required doses to inform use of manipulation in paediatric practice.

    PubMed

    Richey, Roberta H; Hughes, Clare; Craig, Jean V; Shah, Utpal U; Ford, James L; Barker, Catrin E; Peak, Matthew; Nunn, Anthony J; Turner, Mark A

    2017-02-25

    This study sought to determine whether there is an evidence base for drug manipulation to obtain the required dose, a common feature of paediatric clinical practice. A systematic review of the data sources, PubMed, EMBASE, CINAHL, IPA and the Cochrane database of systematic reviews, was used. Studies that considered the dose accuracy of manipulated medicines of any dosage form, evidence of safety or harm, bioavailability, patient experience, tolerability, contamination and comparison of methods of manipulation were included. Case studies and letters were excluded. Fifty studies were eligible for inclusion, 49 of which involved tablets being cut, split, crushed or dispersed. The remaining one study involved the manipulation of suppositories of one drug. No eligible studies concerning manipulation of oral capsules or liquids, rectal enemas, nebuliser solutions, injections or transdermal patches were identified. Twenty four of the tablet studies considered dose accuracy using weight and/or drug content. In studies that considered weight using adapted pharmacopoeial specifications, the percentage of halved tablets meeting these specifications ranged from 30% to 100%. Eighteen studies investigated bioavailability, pharmacokinetics or clinical outcomes following manipulations which included nine delayed or modified release formulations. In each of these nine studies the entirety of the dosage form was administered. Only one of the 18 studies was identified where drugs were manipulated to obtain a proportion of the dosage form, and that proportion administered. The five studies that considered patient perception found that having to manipulate the tablets did not have a negative impact on adherence. Of the 49 studies only two studies reported investigating children. This review yielded limited evidence to support manipulation of medicines for children. The results cannot be extrapolated between dosage forms, methods of manipulation or between different brands of the same

  8. The Prevalence and Clinical Features of Non-responsive Gastroesophageal Reflux Disease to Practical Proton Pump Inhibitor Dose in Korea: A Multicenter Study.

    PubMed

    Park, Hong Jun; Park, Soo Heon; Shim, Ki Nam; Kim, Yong Sung; Kim, Hyun Jin; Han, Jae Pil; Kim, Yong Sik; Bang, Byoung Wook; Kim, Gwang Ha; Baik, Gwang Ho; Kim, Hyung Hun; Park, Seon Young; Kim, Sung Soo

    2016-07-25

    In Korea, there are no available multicenter data concerning the prevalence of or diagnostic approaches for non-responsive gastroesophageal reflux disease (GERD) which does not respond to practical dose of proton pump inhibitor (PPI) in Korea. The purpose of this study is to evaluate the prevalence and the symptom pattern of non-responsive GERD. A total of 12 hospitals who were members of a Korean GERD research group joined this study. We used the composite score (CS) as a reflux symptom scale which is a standardized questionnaire based on the frequency and severity of typical symptoms of GERD. We defined "non-responsive GERD" as follows: a subject with the erosive reflux disease (ERD) whose CS was not decreased by at least 50% after standard-dose PPIs for 8 weeks or a subject with non-erosive reflux disease (NERD) whose CS was not decreased by at least 50% after half-dose PPIs for 4 weeks. A total of 234 subjects were analyzed. Among them, 87 and 147 were confirmed to have ERD and NERD, respectively. The prevalence of non-responsive GERD was 26.9% (63/234). The rates of non-responsive GERD were not different between the ERD and NERD groups (25.3% vs. 27.9%, respectively, p=0.664). There were no differences between the non-responsive GERD and responsive GERD groups for sex (p=0.659), age (p=0.134), or BMI (p=0.209). However, the initial CS for epigastric pain and fullness were higher in the non-responsive GERD group (p=0.044, p=0.014, respectively). In conclusion, this multicenter Korean study showed that the rate of non-responsive GERD was substantially high up to 26%. In addition, the patients with the non-responsive GERD frequently showed dyspeptic symptoms such as epigastric pain and fullness.

  9. Using machine learning to model dose-response relationships.

    PubMed

    Linden, Ariel; Yarnold, Paul R; Nallamothu, Brahmajee K

    2016-12-01

    Establishing the relationship between various doses of an exposure and a response variable is integral to many studies in health care. Linear parametric models, widely used for estimating dose-response relationships, have several limitations. This paper employs the optimal discriminant analysis (ODA) machine-learning algorithm to determine the degree to which exposure dose can be distinguished based on the distribution of the response variable. By framing the dose-response relationship as a classification problem, machine learning can provide the same functionality as conventional models, but can additionally make individual-level predictions, which may be helpful in practical applications like establishing responsiveness to prescribed drug regimens. Using data from a study measuring the responses of blood flow in the forearm to the intra-arterial administration of isoproterenol (separately for 9 black and 13 white men, and pooled), we compare the results estimated from a generalized estimating equations (GEE) model with those estimated using ODA. Generalized estimating equations and ODA both identified many statistically significant dose-response relationships, separately by race and for pooled data. Post hoc comparisons between doses indicated ODA (based on exact P values) was consistently more conservative than GEE (based on estimated P values). Compared with ODA, GEE produced twice as many instances of paradoxical confounding (findings from analysis of pooled data that are inconsistent with findings from analyses stratified by race). Given its unique advantages and greater analytic flexibility, maximum-accuracy machine-learning methods like ODA should be considered as the primary analytic approach in dose-response applications. © 2016 John Wiley & Sons, Ltd.

  10. Dose constraints for moderate hypofractionated radiotherapy for prostate cancer: The French genito-urinary group (GETUG) recommendations.

    PubMed

    Langrand-Escure, J; de Crevoisier, R; Llagostera, C; Créhange, G; Delaroche, G; Lafond, C; Bonin, C; Bideault, F; Sargos, P; Belhomme, S; Pasquier, D; Latorzeff, I; Supiot, S; Hennequin, C

    2018-04-01

    Considering recent phase III trials results, moderate hypofractionated radiotherapy can be considered as a standard treatment for low and intermediate risk prostate cancer management. This assessment call for a framework allowing homogeneous and reproducible practices in the different centers using this radiotherapy schedule. The French Genito-Urinary Group (GETUG) provides here recommendations for daily practice of moderate hypofractionated radiotherapy for prostate cancer, with indications, dose, fractionation, pre-treatment planning, volume of interest delineation (target volume and organs at risk) and margins, dose constraints and radiotherapy techniques. Copyright © 2018. Published by Elsevier SAS.

  11. Duration of protection against hepatitis A for the current two-dose vaccine compared to a three-dose vaccine schedule in children

    PubMed Central

    Raczniak, Gregory A.; Thomas, Timothy K.; Bulkow, Lisa R.; Negus, Susan E.; Zanis, Carolyn L.; Bruce, Michael G.; Spradling, Philip R.; Teshale, Eyasu H.; McMahon, Brian J.

    2015-01-01

    Background Hepatitis A is mostly a self-limiting disease but causes substantial economic burden. Consequently, United States Advisory Committee for Immunization Practices recommends inactivated hepatitis A vaccination for all children beginning at age 1 year and for high risk adults. The hepatitis A vaccine is highly effective but the duration of protection is unknown. Methods We examined the proportion of children with protective hepatitis A antibody levels (anti-HAV ≥20 mIU/mL) as well as the geometric mean concentration (GMC) of anti-HAV in a cross sectional convenience sample of individuals aged 12–24 years, who had been vaccinated with a two-dose schedule in childhood, with the initial dose at least 5 years ago. We compared a subset of data from persons vaccinated with two-doses (720 EL.U.) at age 3–6 years with a demographically similar prospective cohort that received a three-dose (360 EL.U.) schedule and have been followed for 17 years. Results No significant differences were observed when comparing GMC between the two cohorts at 10 (P = 0.467), 12 (P = 0.496), and 14 (P = 0.175) years post-immunization. For the three-dose cohort, protective antibody levels remain for 17 years and have leveled-off over the past 7 years. Conclusion The two- and three-dose schedules provide similar protection >14 years after vaccination, indicating a booster dose is not needed at this time. Plateauing anti-HAV GMC levels suggest protective antibody levels may persist long-term. PMID:23470239

  12. The Eclipse of Imagination within Educational "Official" Framework and Why It Should Be Returned to Educational Discourse: A Deweyan Perspective

    ERIC Educational Resources Information Center

    d'Agnese, Vasco

    2017-01-01

    In recent decades, the shift towards the "learnification" of educational discourse has "de facto" reframed educational purposes and schooling practice, thus reframing what students should know, strive for, and, in a sense, be. In this paper, given the efforts to disrupt the dominance of learning discourse, I seek to engage…

  13. Field evaluations of the VD max approach for substantiation of a 25 kGy sterilization dose and its application to other preselected doses

    NASA Astrophysics Data System (ADS)

    Kowalski, John B.; Herring, Craig; Baryschpolec, Lisa; Reger, John; Patel, Jay; Feeney, Mary; Tallentire, Alan

    2002-08-01

    The International and European standards for radiation sterilization require evidence of the effectiveness of a minimum sterilization dose of 25 kGy but do not provide detailed guidance on how this evidence can be generated. An approach, designated VD max, has recently been described and computer evaluated to provide safe and unambiguous substantiation of a 25 kGy sterilization dose. The approach has been further developed into a practical method, which has been subjected to field evaluations at three manufacturing facilities which produce different types of medical devices. The three facilities each used a different overall evaluation strategy: Facility A used VD max for quarterly dose audits; Facility B compared VD max and Method 1 in side-by-side parallel experiments; and Facility C, a new facility at start-up, used VD max for initial substantiation of 25 kGy and subsequent quarterly dose audits. A common element at all three facilities was the use of 10 product units for irradiation in the verification dose experiment. The field evaluations of the VD max method were successful at all three facilities; they included many different types of medical devices/product families with a wide range of average bioburden and sample item portion values used in the verification dose experiments. Overall, around 500 verification dose experiments were performed and no failures were observed. In the side-by-side parallel experiments, the outcomes of the VD max experiments were consistent with the outcomes observed with Method 1. The VD max approach has been extended to sterilization doses >25 and <25 kGy; verification doses have been derived for sterilization doses of 15, 20, 30, and 35 kGy. Widespread application of the VD max method for doses other than 25 kGy must await controlled field evaluations and the development of appropriate specifications/standards.

  14. Radioiodine (1-131) Dose for the Treatment of Hyperthyroidism in Rajavithi Hospital.

    PubMed

    Kuanrakcharoen, Pichit

    2016-02-01

    -131 is the treatment of choice for hyperthyroidism after medical therapy failure, and there are various techniques for determining the optimal dose. At Rajavithi Hospital, the I-131 dose (mean = 14.84 ± 5.71 mCi) is estimated based on the gland weight by palpation and other additional clinical factors. The present study provided a practical formula which is simple and practical for use in determining the I-131 dose for the treatment of hyperthyroidism: Dose of I-131 (mCi) = 0.235 x gland size (g).

  15. Survey of computed tomography scanners in Taiwan: Dose descriptors, dose guidance levels, and effective doses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tsai, H. Y.; Tung, C. J.; Yu, C. C.

    2007-04-15

    The IAEA and the ICRP recommended dose guidance levels for the most frequent computed tomography (CT) examinations to promote strategies for the optimization of radiation dose to CT patients. A national survey, including on-site measurements and questionnaires, was conducted in Taiwan in order to establish dose guidance levels and evaluate effective doses for CT. The beam quality and output and the phantom doses were measured for nine representative CT scanners. Questionnaire forms were completed by respondents from facilities of 146 CT scanners out of 285 total scanners. Information on patient, procedure, scanner, and technique for the head and body examinationsmore » was provided. The weighted computed tomography dose index (CTDI{sub w}), the dose length product (DLP), organ doses and effective dose were calculated using measured data, questionnaire information and Monte Carlo simulation results. A cost-effective analysis was applied to derive the dose guidance levels on CTDI{sub w} and DLP for several CT examinations. The mean effective dose{+-}standard deviation distributes from 1.6{+-}0.9 mSv for the routine head examination to 13{+-}11 mSv for the examination of liver, spleen, and pancreas. The surveyed results and the dose guidance levels were provided to the national authorities to develop quality control standards and protocols for CT examinations.« less

  16. Prediction of standard-dose brain PET image by using MRI and low-dose brain [{sup 18}F]FDG PET images

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kang, Jiayin; Gao, Yaozong; Shi, Feng

    Purpose: Positron emission tomography (PET) is a nuclear medical imaging technology that produces 3D images reflecting tissue metabolic activity in human body. PET has been widely used in various clinical applications, such as in diagnosis of brain disorders. High-quality PET images play an essential role in diagnosing brain diseases/disorders. In practice, in order to obtain high-quality PET images, a standard-dose radionuclide (tracer) needs to be used and injected into a living body. As a result, it will inevitably increase the patient’s exposure to radiation. One solution to solve this problem is predicting standard-dose PET images using low-dose PET images. Asmore » yet, no previous studies with this approach have been reported. Accordingly, in this paper, the authors propose a regression forest based framework for predicting a standard-dose brain [{sup 18}F]FDG PET image by using a low-dose brain [{sup 18}F]FDG PET image and its corresponding magnetic resonance imaging (MRI) image. Methods: The authors employ a regression forest for predicting the standard-dose brain [{sup 18}F]FDG PET image by low-dose brain [{sup 18}F]FDG PET and MRI images. Specifically, the proposed method consists of two main steps. First, based on the segmented brain tissues (i.e., cerebrospinal fluid, gray matter, and white matter) in the MRI image, the authors extract features for each patch in the brain image from both low-dose PET and MRI images to build tissue-specific models that can be used to initially predict standard-dose brain [{sup 18}F]FDG PET images. Second, an iterative refinement strategy, via estimating the predicted image difference, is used to further improve the prediction accuracy. Results: The authors evaluated their algorithm on a brain dataset, consisting of 11 subjects with MRI, low-dose PET, and standard-dose PET images, using leave-one-out cross-validations. The proposed algorithm gives promising results with well-estimated standard-dose brain [{sup 18}F

  17. Evaluation of radiation dose of triple rule-out coronary angiography protocols with different scan length using 256-slice CT

    NASA Astrophysics Data System (ADS)

    Tsai, Chia-Jung; Lee, Jason J. S.; Chen, Liang-Kuang; Mok, Greta S. P.; Hsu, Shih-Ming; Wu, Tung-Hsin

    2011-10-01

    Triple rule-out coronary CT angiography (TRO-CTA) is a new approach for providing noninvasive visualization of coronary arteries with simultaneous evaluation of pulmonary arteries, thoracic aorta and other intrathoracic structures. The increasing use of TRO-CTA examination with longer scan length is associated with the concerns about radiation dose and their corresponding cancer risk. The purpose of this study is to evaluate organ dose and effective dose for the TRO-CTA examination with 2 scan lengths: TRO std and TRO ext, using 256-slice CT. TRO-CTA examinations were performed on a 256-slice CT scanner without ECG-based tube current modulation. Absorbed organ doses were measured using an anthropomorphic phantom and thermal-luminance dosimeters (TLDs). Effective dose was determined by taking a sum of the measured absorbed organ doses multiplied with the tissue weighting factor based on ICRP-103, and compared to that calculated using the dose-length product (DLP) method. We obtained high organ doses in the thyroid, esophagus, breast, heart and lung in both TRO-CTA protocols. Effective doses of the TRO std and TRO ext protocols with the phantom method were 26.37 and 42.49 mSv, while those with the DLP method were 19.68 and 38.96 mSv, respectively. Our quantitative dose information establishes a relationship between radiation dose and scanning length, and can provide a practical guidance to best clinical practice.

  18. Estimation of the Dose and Dose Rate Effectiveness Factor

    NASA Technical Reports Server (NTRS)

    Chappell, L.; Cucinotta, F. A.

    2013-01-01

    Current models to estimate radiation risk use the Life Span Study (LSS) cohort that received high doses and high dose rates of radiation. Transferring risks from these high dose rates to the low doses and dose rates received by astronauts in space is a source of uncertainty in our risk calculations. The solid cancer models recommended by BEIR VII [1], UNSCEAR [2], and Preston et al [3] is fitted adequately by a linear dose response model, which implies that low doses and dose rates would be estimated the same as high doses and dose rates. However animal and cell experiments imply there should be curvature in the dose response curve for tumor induction. Furthermore animal experiments that directly compare acute to chronic exposures show lower increases in tumor induction than acute exposures. A dose and dose rate effectiveness factor (DDREF) has been estimated and applied to transfer risks from the high doses and dose rates of the LSS cohort to low doses and dose rates such as from missions in space. The BEIR VII committee [1] combined DDREF estimates using the LSS cohort and animal experiments using Bayesian methods for their recommendation for a DDREF value of 1.5 with uncertainty. We reexamined the animal data considered by BEIR VII and included more animal data and human chromosome aberration data to improve the estimate for DDREF. Several experiments chosen by BEIR VII were deemed inappropriate for application to human risk models of solid cancer risk. Animal tumor experiments performed by Ullrich et al [4], Alpen et al [5], and Grahn et al [6] were analyzed to estimate the DDREF. Human chromosome aberration experiments performed on a sample of astronauts within NASA were also available to estimate the DDREF. The LSS cohort results reported by BEIR VII were combined with the new radiobiology results using Bayesian methods.

  19. Impact of high- versus low-dose neuromuscular blocking agent administration on unplanned 30-day readmission rates in retroperitoneal laparoscopic surgery.

    PubMed

    Boon, Martijn; Martini, Chris; Yang, H Keri; Sen, Shuvayu S; Bevers, Rob; Warlé, Michiel; Aarts, Leon; Niesters, Marieke; Dahan, Albert

    2018-01-01

    Recent data shows that a neuromuscular block (NMB) induced by administration of high doses of rocuronium improves surgical conditions in certain procedures. However, there are limited data on the effect such practices on postoperative outcomes. We performed a retrospective analysis to compare unplanned 30-day readmissions in patients that received high-dose versus low-dose rocuronium administration during general anesthesia for laparoscopic retroperitoneal surgery. This retrospective cohort study was performed in the Netherlands in an academic hospital where routine high-dose rocuronium NMB has been practiced since July 2015. Charts of patients receiving anesthesia between January 2014 and December 2016 were searched for surgical cases receiving high-dose rocuronium and matched with respect to procedure, age, sex and ASA classification to patients receiving low-dose rocuronium. The primary post-operative outcome was unplanned 30-day readmission rate. There were 130 patients in each cohort. Patients in the high- and low-dose rocuronium cohorts received 217 ± 49 versus 37 ± 5 mg rocuronium, respectively. In the high-dose rocuronium group neuromuscular activity was consistently monitored; matched patients were unreliably monitored. All patients receiving high-dose rocuronium were reversed with sugammadex, while just 33% of matched patients were reversed with sugammadex and 20% with neostigmine; the remaining patients were not reversed. Unplanned 30-day readmission rate was significantly lower in the high-dose compared to the low-dose rocuronium cohort (3.8% vs. 12.7%; p = 0.03; odds ratio = 0.33, 95% C.I. 0.12-0.95). This small retrospective study demonstrates a lower incidence of unplanned readmissions within 30-days following laparoscopic retroperitoneal surgery with high-dose relaxant anesthesia and sugammadex reversal in comparison to low-dose relaxant anesthesia. Further prospective studies are needed in larger samples to corroborate our findings and

  20. Toward a unified approach to dose-response modeling in ecotoxicology.

    PubMed

    Ritz, Christian

    2010-01-01

    This study reviews dose-response models that are used in ecotoxicology. The focus lies on clarification of differences and similarities between models, and as a side effect, their different guises in ecotoxicology are unravelled. A look at frequently used dose-response models reveals major discrepancies, among other things in naming conventions. Therefore, there is a need for a unified view on dose-response modeling in order to improve the understanding of it and to facilitate communication and comparison of findings across studies, thus realizing its full potential. This study attempts to establish a general framework that encompasses most dose-response models that are of interest to ecotoxicologists in practice. The framework includes commonly used models such as the log-logistic and Weibull models, but also features entire suites of models as found in various guidance documents. An outline on how the proposed framework can be implemented in statistical software systems is also provided.

  1. A national patient dose survey and setting of reference levels for interventional radiology in Bulgaria.

    PubMed

    Zotova, R; Vassileva, J; Hristova, J; Pirinen, M; Järvinen, H

    2012-06-01

    A national study on patient dose values in interventional radiology and cardiology was performed in order to assess current practice in Bulgaria, to estimate the typical patient doses and to propose reference levels for the most common procedures. Fifteen units and more than 1,000 cases were included. Average values of the measured parameters for three procedures-coronary angiography (CA), combined procedure (CA + PCI) and lower limb arteriography (LLA)--were compared with data published in the literature. Substantial variations were observed in equipment and procedure protocols used. This resulted in variations in patient dose: air-kerma area product ranges were 4-339, 6-1,003 and 0.2-288 Gy cm(2) for CA, CA + PCI and LLA respectively. Reference levels for air kerma-area product were proposed: 40 Gy cm(2) for CA, 140 Gy cm(2) for CA + PCI and 45 Gy cm(2) for LLA. Auxiliary reference intervals were proposed for other dose-related parameters: fluoroscopy time, number of images and entrance surface air kerma rate in fluoroscopy and cine mode. There is an apparent necessity for improvement in the classification of peripheral procedures and for standardisation of the protocols applied. It is important that patient doses are routinely recorded and compared with reference levels. • Patient doses in interventional radiology are high and vary greatly • Better standardisation of procedures and techniques is needed to improve practiceDose reference levels for most common procedures are proposed.

  2. SU-F-T-600: Influence of Acuros XB and AAA Dose Calculation Algorithms On Plan Quality Metrics and Normal Lung Doses in Lung SBRT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yaparpalvi, R; Mynampati, D; Kuo, H

    Purpose: To study the influence of superposition-beam model (AAA) and determinant-photon transport-solver (Acuros XB) dose calculation algorithms on the treatment plan quality metrics and on normal lung dose in Lung SBRT. Methods: Treatment plans of 10 Lung SBRT patients were randomly selected. Patients were prescribed to a total dose of 50-54Gy in 3–5 fractions (10?5 or 18?3). Doses were optimized accomplished with 6-MV using 2-arcs (VMAT). Doses were calculated using AAA algorithm with heterogeneity correction. For each plan, plan quality metrics in the categories- coverage, homogeneity, conformity and gradient were quantified. Repeat dosimetry for these AAA treatment plans was performedmore » using AXB algorithm with heterogeneity correction for same beam and MU parameters. Plan quality metrics were again evaluated and compared with AAA plan metrics. For normal lung dose, V{sub 20} and V{sub 5} to (Total lung- GTV) were evaluated. Results: The results are summarized in Supplemental Table 1. PTV volume was mean 11.4 (±3.3) cm{sup 3}. Comparing RTOG 0813 protocol criteria for conformality, AXB plans yielded on average, similar PITV ratio (individual PITV ratio differences varied from −9 to +15%), reduced target coverage (−1.6%) and increased R50% (+2.6%). Comparing normal lung doses, the lung V{sub 20} (+3.1%) and V{sub 5} (+1.5%) were slightly higher for AXB plans compared to AAA plans. High-dose spillage ((V105%PD - PTV)/ PTV) was slightly lower for AXB plans but the % low dose spillage (D2cm) was similar between the two calculation algorithms. Conclusion: AAA algorithm overestimates lung target dose. Routinely adapting to AXB for dose calculations in Lung SBRT planning may improve dose calculation accuracy, as AXB based calculations have been shown to be closer to Monte Carlo based dose predictions in accuracy and with relatively faster computational time. For clinical practice, revisiting dose-fractionation in Lung SBRT to correct for dose

  3. Occupational radiation dose to eyes from endoscopic retrograde cholangiopancreatography procedures in light of the revised eye lens dose limit from the International Commission on Radiological Protection.

    PubMed

    O'Connor, U; Gallagher, A; Malone, L; O'Reilly, G

    2013-02-01

    Endoscopic retrograde cholangiopancreatography (ERCP) is a common procedure that combines the use of X-ray fluoroscopy and endoscopy for examination of the bile duct. Published data on ERCP doses are limited, including staff eye dose from ERCP. Occupational eye doses are of particular interest now as the International Commission on Radiological Protection (ICRP) has recommended a reduction in the dose limit to the lens of the eye. The aim of this study was to measure occupational eye doses obtained from ERCP procedures. A new eye lens dosemeter (EYE-D(™), Radcard, Krakow, Poland) was used to measure the ERCP eye dose, H(p)(3), at two endoscopy departments in Ireland. A review of radiation protection practice at the two facilities was also carried out. The mean equivalent dose to the lens of the eye of a gastroenterologist is 0.01 mSv per ERCP procedure with an undercouch X-ray tube and 0.09 mSv per ERCP procedure with an overcouch X-ray tube. Staff eye dose normalised to patient kerma area product is also presented. Staff eye doses in ERCP have the potential to exceed the revised ICRP limit of 20 mSv per annum when an overcouch X-ray tube is used. The EYE-D dosemeter was found to be a convenient method for measuring lens dose. Eye doses in areas outside of radiology departments should be kept under review, particularly in light of the new ICRP eye dose limit. Occupational eye lens doses from ERCP procedures have been established using a new commercially available dedicated H(p)(3) dosemeter.

  4. Does intravenous induction dosing among patients undergoing gastrointestinal surgical procedures follow current recommendations: a study of contemporary practice.

    PubMed

    Akhtar, Shamsuddin; Liu, Jia; Heng, Joseph; Dai, Feng; Schonberger, Robert B; Burg, Matthew M

    2016-09-01

    It is recommended to correct intravenous induction doses by up to 50% for patients older than 65 years. The objectives were to determine (a) the degree to which anesthesia providers correct induction doses for age and (b) additionally adjust for American Society of Anesthesiologists physical status (ASA-PS) class (severity of illness) and (c) whether postinduction hypotension is more common among patients aged >65. Retrospective chart review. Academic medical center. A total of 1869 adult patients receiving general anesthesia for GI surgical procedures from February 2013 to January 2014. Patients were divided into 3 age groups (age <65, 65-79, ≥80 years) and then further stratified into ASA-PS class (I/II vs III/IV). Multiple pairwise comparisons were conducted using Welch t tests for continuous variables to determine whether dosing was different for the older groups vs the younger group; separate analyses were performed within and across ASA-PS class. This approach was also used to determine differences in mean arterial pressure change in the older groups vs the younger group, whereas the rates of hypotension among different age groups were compared by Cochran-Armitage trend test. No significant decrease in dosing between age groups was observed for fentanyl and midazolam. For propofol, there was a significantly lower dosing for older patients: 17% for patients aged 65-79 and 29% for those aged >80, which was still in less than the recommendations. An inverse relationship was observed between propofol dosing and ASA-PS class, but no consistent relationship was noted for fentanyl and midazolam. There were a significantly larger drop in mean arterial pressure and a greater likelihood of hypotension following induction in patients aged 65-79 years and >80 years as compared with those aged <65 years. This study shows that the administered dose of anesthetic induction agents is significantly higher than that recommended for patients older than 65 years. This failure

  5. Influence of Age on Frequency of Vancomycin Dosing

    PubMed Central

    Legal, Michael; Wan, Marisa

    2010-01-01

    Background: Vancomycin is commonly prescribed at the authors’ institution because of a high prevalence of invasive infections caused by methicillin-resistant Staphylococcus aureus (MRSA) in a generally younger population. The most commonly prescribed empiric dosing interval is every 12 h (q12h). However, observations have suggested that younger adult patients require more frequent dosing, such as every 8 h (q8h). Initial underdosing of vancomycin may increase the risk of antibiotic failure. Objective: To determine whether patients under 40 years of age are more likely than older patients to require q8h dosing of vancomycin and whether recommendations can be made to alter current prescribing practices. Methods: This retrospective unmatched case–control study involved patients who had received vancomycin for suspected or confirmed severe MRSA infections. The cases were patients who had been confirmed as requiring q8h dosing, and the controls were patients who had been confirmed as requiring q12h dosing (on the basis of target predose serum levels). The influence of age (the predictor variable) on outcome (the vancomycin regimen) was evaluated by logistic regression. Results: The odds ratio for patients under 40 years of age requiring q8h dosing was 3.1 (95% confidence interval 1.5–6.3) (p = 0.002). Sixty percent of patients under 40 ultimately required a q8h regimen to achieve target predose serum levels. Patients who required q8h dosing took longer to achieve their first therapeutic serum level than those with q12h dosing (median 6 versus 4 days; p < 0.001). Conclusions: In this patient population, age less than 40 years was a strong predictor for requiring more frequent dosing of vancomycin. The authors suggest that doses of 15 mg/kg IV q8h be used empirically for younger patients with severe infections and normal renal function. PMID:22478948

  6. Dosing of selective serotonin reuptake inhibitors in children and adults before and after the FDA black-box warning

    PubMed Central

    Bushnell, Greta A; Stürmer, Til; Swanson, Sonja A; White, Alice; Azrael, Deborah; Pate, Virginia; Miller, Matthew

    2016-01-01

    Objective Prior research evaluated various effects of the antidepressant black-box warning on the risk of suicidality in children, but the dosing of antidepressants has not been considered. This study estimated, relative to the FDA warnings, whether the initial antidepressant dose prescribed decreased and the proportion augmenting dose on the second fill increased. Method The study utilized the LifeLink Health Plan Claims Database. The study cohort consisted of commercially insured children (5–17 years), young adults (18–24 years), and adults (25–64 years) initiating an SSRI (citalopram, fluoxetine, paroxetine, or sertraline) from 1/1/2000 to 12/31/2009. Dose-per-day was determined by days supply, strength, and quantity dispensed. Initiation on low dose, defined based on guidelines, and dose augmentations (dose increase >1mg/day) on the second prescription were considered across time periods related to the antidepressant warnings. Results Of 51,948 children who initiated an SSRI, 15% initiated on low dose in the period before the 2004 black-box warning and 31% in the period after the warning (a 16 percentage-point change); there was a smaller percentage-point change in young adults (6%) and adults (3%). The overall increase in dose augmentations in children and young adults was driven by the increase in patients initiating on a low dose. Conclusions As guidelines recommend children initiate antidepressant treatment on low dose, findings that an increased proportion of commercially insured children initiated an SSRI on low dose after the 2004 black-box warning suggest prescribing practices surrounding SSRI dosing improved in children following the warning but dosing practices still fall short of guidelines. PMID:26567938

  7. Working through the Challenges: Struggle and Resilience within the Historically Black Land Grant Institutions

    ERIC Educational Resources Information Center

    Harris, Rosalind P.; Worthen, H. Dreamal

    2004-01-01

    In 1890 the Morrill-McComas Act provided for the establishment of segregated land grant colleges within the sixteen southern and border states practicing both "de jure" and "de facto" racial discrimination. This article reviews the significant role played by the legacies of racial discrimination, funding inequities and the model of institution…

  8. Evidence-based algorithm for heparin dosing before cardiopulmonary bypass. Part 1: Development of the algorithm.

    PubMed

    McKinney, Mark C; Riley, Jeffrey B

    2007-12-01

    The incidence of heparin resistance during adult cardiac surgery with cardiopulmonary bypass has been reported at 15%-20%. The consistent use of a clinical decision-making algorithm may increase the consistency of patient care and likely reduce the total required heparin dose and other problems associated with heparin dosing. After a directed survey of practicing perfusionists regarding treatment of heparin resistance and a literature search for high-level evidence regarding the diagnosis and treatment of heparin resistance, an evidence-based decision-making algorithm was constructed. The face validity of the algorithm decisive steps and logic was confirmed by a second survey of practicing perfusionists. The algorithm begins with review of the patient history to identify predictors for heparin resistance. The definition for heparin resistance contained in the algorithm is an activated clotting time < 450 seconds with > 450 IU/kg heparin loading dose. Based on the literature, the treatment for heparin resistance used in the algorithm is anti-thrombin III supplement. The algorithm seems to be valid and is supported by high-level evidence and clinician opinion. The next step is a human randomized clinical trial to test the clinical procedure guideline algorithm vs. current standard clinical practice.

  9. Hepatitis B vaccine booster dose: low-dose recombinant hepatitis B vaccines as a booster dose.

    PubMed

    Bryan, J P; MacArthy, P; Rudock, A; Fogarty, J P; Dowd, H; Legters, L J; Perine, P L

    1997-06-01

    The timing and best regimen for a booster dose of hepatitis B vaccine have not been determined. Two studies were conducted to determine the response to a booster dose of 5 micrograms recombinant hepatitis B vaccine. In the first study, a 5 micrograms (0.5 ml) dose of Recombivax HB was administered intramuscularly 38 months after the initial dose to 71 volunteers. In a second study, we offered a 5 micrograms dose recombinant hepatitis B vaccine, either Recombivax HB (0.5 ml) or Engerix B (0.25 ml), to students who had previously been immunized with three doses of vaccine. In the first study, among the 44 persons for whom postbooster sera were available, the geometric mean concentration of anti-hepatitis B surface antigens increased from 42 to 2090 mIU/ml after the 5 micrograms (0.5 ml) dose of Recombivax. In the second study, after a 5 micrograms (0.5 ml) dose of Recombivax, the geometric mean concentration increased from 43 to 990 mIU/ml (n = 48), and in the group that received a 5 micrograms (0.25 ml) dose of Engerix B, the concentration increased from 83 to 2337 mIU/ml (n = 45) (p = 0.18 for postdose concentrations). A 5 micrograms dose of recombinant vaccine results in an excellent booster response at a cost one fourth to one half that of a full 1 ml dose of vaccine.

  10. Application of the ELDO approach to assess cumulative eye lens doses for interventional cardiologists.

    PubMed

    Farah, J; Struelens, L; Auvinen, A; Jacob, S; Koukorava, C; Schnelzer, M; Vanhavere, F; Clairand, I

    2015-04-01

    In preparation of a large European epidemiological study on the relation between eye lens dose and the occurrence of lens opacities, the European ELDO project focused on the development of practical methods to estimate retrospectively cumulative eye lens dose for interventional medical professionals exposed to radiation. The present paper applies one of the ELDO approaches, correlating eye lens dose to whole-body doses, to assess cumulative eye lens dose for 14 different Finnish interventional cardiologists for whom annual whole-body dose records were available for their entire working period. The estimated cumulative left and right eye lens dose ranged from 8 to 264 mSv and 6 to 225 mSv, respectively. In addition, calculations showed annual eye lens doses sometimes exceeding the new ICRP annual limit of 20 mSv. The work also highlights the large uncertainties associated with the application of such an approach proving the need for dedicated dosimetry systems in the routine monitoring of the eye lens dose. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  11. Effect of staff training on radiation dose in pediatric CT.

    PubMed

    Hojreh, Azadeh; Weber, Michael; Homolka, Peter

    2015-08-01

    To evaluate the efficacy of staff training on radiation doses applied in pediatric CT scans. Pediatric patient doses from five CT scanners before (1426 scans) and after staff training (2566 scans) were compared statistically. Examinations included cranial CT (CCT), thoracic, abdomen-pelvis, and trunk scans. Dose length products (DLPs) per series were extracted from CT dose reports archived in the PACS. A pooled analysis of non-traumatic scans revealed a statistically significant reduction in the dose for cranial, thoracic, and abdomen/pelvis scans (p<0.01). This trend could be demonstrated also for trunk scans, however, significance could not be established due to low patient frequencies (p>0.05). The percentage of scans performed with DLPs exceeding the German DRLs was reduced from 41% to 7% (CCT), 19% to 5% (thorax-CT), from 9% to zero (abdominal-pelvis CT), and 26% to zero (trunk; DRL taken as summed DRLs for thorax plus abdomen-pelvis, reduced by 20% accounting for overlap). Comparison with Austrian DRLs - available only for CCT and thorax CT - showed a reduction from 21% to 3% (CCT), and 15 to 2% (thorax CT). Staff training together with application of DRLs provide an efficient approach for optimizing radiation dose in pediatric CT practice. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  12. Medication Administration Practices of School Nurses.

    ERIC Educational Resources Information Center

    McCarthy, Ann Marie; Kelly, Michael W.; Reed, David

    2000-01-01

    Assessed medication administration practices among school nurses, surveying members of the National Association of School Nurses. Respondents were extremely concerned about medication administration. Errors in administering medications were reported by 48.5 percent of respondents, with missed doses the most common error. Most nurses followed…

  13. Using lean "automation with a human touch" to improve medication safety: a step closer to the "perfect dose".

    PubMed

    Ching, Joan M; Williams, Barbara L; Idemoto, Lori M; Blackmore, C Craig

    2014-08-01

    Virginia Mason Medical Center (Seattle) employed the Lean concept of Jidoka (automation with a human touch) to plan for and deploy bar code medication administration (BCMA) to hospitalized patients. Integrating BCMA technology into the nursing work flow with minimal disruption was accomplished using three steps ofJidoka: (1) assigning work to humans and machines on the basis of their differing abilities, (2) adapting machines to the human work flow, and (3) monitoring the human-machine interaction. Effectiveness of BCMA to both reinforce safe administration practices and reduce medication errors was measured using the Collaborative Alliance for Nursing Outcomes (CALNOC) Medication Administration Accuracy Quality Study methodology. Trained nurses observed a total of 16,149 medication doses for 3,617 patients in a three-year period. Following BCMA implementation, the number of safe practice violations decreased from 54.8 violations/100 doses (January 2010-September 2011) to 29.0 violations/100 doses (October 2011-December 2012), resulting in an absolute risk reduction of 25.8 violations/100 doses (95% confidence interval [CI]: 23.7, 27.9, p < .001). The number of medication errors decreased from 5.9 errors/100 doses at baseline to 3.0 errors/100 doses after BCMA implementation (absolute risk reduction: 2.9 errors/100 doses [95% CI: 2.2, 3.6,p < .001]). The number of unsafe administration practices (estimate, -5.481; standard error 1.133; p < .001; 95% CI: -7.702, -3.260) also decreased. As more hospitals respond to health information technology meaningful use incentives, thoughtful, methodical, and well-managed approaches to technology deployment are crucial. This work illustrates how Jidoka offers opportunities for a smooth transition to new technology.

  14. Electrocardiogram‐gated coronary CT angiography dose estimates using ImPACT

    PubMed Central

    Asada, Yasuki; Matsubara, Kosuke; Suzuki, Shouichi; Koshida, Kichiro; Matsunaga, Yuta; Haba, Tomonobu; Kawaguchi, Ai; Toyama, Hiroshi; Kato, Ryoichi

    2016-01-01

    The primary study objective was to assess radiation doses using a modified form of the Imaging Performance Assessment of Computed Tomography (CT) scanner (ImPACT) patient dosimetry for cardiac applications on an Aquilion ONE ViSION Edition scanner, including the Ca score, target computed tomography angiography (CTA), prospective CTA, continuous CTA/cardiac function analysis (CFA), and CTA/CFA modulation. Accordingly, we clarified the CT dose index (CTDI) to determine the relationship between heart rate (HR) and X‐ray exposure. As a secondary objective, we compared radiation doses using modified ImPACT, a whole‐body dosimetry phantom study, and the k‐factor method to verify the validity of the dose results obtained with modified ImPACT. The effective dose determined for the reference person (4.66 mSv at 60 beats per minute (bpm) and 33.43 mSv at 90 bpm) were approximately 10% less than those determined for the phantom study (5.28 mSv and 36.68 mSv). The effective doses according to the k‐factor (0.014 mSv·mGy−1·cm−1; 2.57 mSv and 17.10 mSv) were significantly lower than those obtained with the other two methods. In the present study, we have shown that ImPACT, when modified for cardiac applications, can assess both absorbed and effective doses. The results of our dose comparison indicate that modified ImPACT dose assessment is a promising and practical method for evaluating coronary CTA. PACS number(s): 87.57.Q‐, 87.59.Dj, 87.57.uq PMID:27455500

  15. Implementation and Challenges of Direct Acoustic Dosing into Cell-Based Assays.

    PubMed

    Roberts, Karen; Callis, Rowena; Ikeda, Tim; Paunovic, Amalia; Simpson, Carly; Tang, Eric; Turton, Nick; Walker, Graeme

    2016-02-01

    Since the adoption of Labcyte Echo Acoustic Droplet Ejection (ADE) technology by AstraZeneca in 2005, ADE has become the preferred method for compound dosing into both biochemical and cell-based assays across AstraZeneca research and development globally. The initial implementation of Echos and the direct dosing workflow provided AstraZeneca with a unique set of challenges. In this article, we outline how direct Echo dosing has evolved over the past decade in AstraZeneca. We describe the practical challenges of applying ADE technology to 96-well, 384-well, and 1536-well assays and how AstraZeneca developed and applied software and robotic solutions to generate fully automated and effective cell-based assay workflows. © 2015 Society for Laboratory Automation and Screening.

  16. Assessment of patient dose and radiogenic risks during endoscopic retrograde cholangiopancreatography.

    PubMed

    Sulieman, A; Elzaki, M; Alkhorayef, M; Babikir, E; Abuzaid, M; Dalton, A; Bradley, D

    2016-11-01

    Endoscopic retrograde cholangiopancreatography (ERCP) is an invasive technique that has been used for over 30 years in the diagnosis and management of pancreaticobiliary disorders. The objectives of this study were to evaluate the patient entrance surface air kerma doses (ESAK) and estimate the organ and effective doses during ERCP in three hospitals in Khartoum. A total of 55 patients were examined in three hospitals in Khartoum state, Sudan. Calibrated thermoluinescent dosimeters (TLD) were used to measure patients' ESAK. Organ and effective doses were estimated using National Radiological Protection Board (NRPB) software. The overall mean of ESAK for all ERCP procedures was 42.4mGy. The mean patient ESAK in Fedail (A), Soba (B) and Ibn sena (C) hospitals were 26.7mGy, 26.0mGy and 72.4mGy, respectively. The effective doses in three hospitals were 1.60, 1.56 and 2.67mSv in that order and the overall mean effective dose was 1.94mSv. Patient radiation doses vary widely among the hospitals. Patient ESAK is low compared to previous studies in the light of the current practice. Patient dose was decreased significantly in the last two decades. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. A Retrospective Observational Study of Anesthetic Induction Dosing Practices in Female Elderly Surgical Patients: Are We Overdosing Older Patients?

    PubMed

    Akhtar, Shamsuddin; Heng, Joseph; Dai, Feng; Schonberger, Robert B; Burg, Mathew M

    2016-10-01

    Despite guidelines suggesting a 25-50 % reduction in induction doses of intravenous anesthetic agents in the elderly (≥65 years), we hypothesized that practitioners were not sufficiently correcting drug administration for age, contributing to an increased incidence of hypotension in older patients undergoing general anesthesia. We conducted a retrospective, observational study in a tertiary-care academic hospital. The study included 768 female patients undergoing gynecologic surgeries who received propofol-based induction of general anesthesia. Weight-adjusted anesthetic induction dosing, age-associated differences in dosing by ASA-PS (American Society of Anesthesiology-Physical Status), and hemodynamic outcomes between younger (18-64 years, n = 537) and older (≥65 years, n = 231) female patients were analyzed. Older patients received lower doses of propofol and midazolam than younger patients (propofol: 2.037 ± 0.783 vs 2.322 ± 0.834 mg/kg, p < 0.001; midazolam: 0.013 ± 0.014 vs 0.023 ± 0.042 mg/kg, p < 0.001). However, practitioners still consistently exceeded the FDA recommended dose (1-1.5 mg/kg) of propofol for elderly patients. There was no significant difference in the doses of fentanyl administered between the two age groups (1.343 ± 0.744 vs 1.363 ± 0.763 μg/kg, p = 0.744), and doses of fentanyl in older patients exceeded the recommended dose (0.5-1.0 μg/kg). Corresponding to observed overdosing of induction agents, older patients experienced larger decreases in post-induction blood pressure and were more likely to receive vasopressor therapy. Anesthetic induction doses of fentanyl and propofol were not sufficiently corrected in older patients in accordance with recommendations. Significantly greater frequency of post-induction hypotension occurred amongst older patients. Quality improvement efforts may lead to improved outcomes in this vulnerable population.

  18. AAPM medical physics practice guideline 6.a.: Performance characteristics of radiation dose index monitoring systems.

    PubMed

    Gress, Dustin A; Dickinson, Renee L; Erwin, William D; Jordan, David W; Kobistek, Robert J; Stevens, Donna M; Supanich, Mark P; Wang, Jia; Fairobent, Lynne A

    2017-07-01

    The American Association of Physicists in Medicine (AAPM) is a nonprofit professional society whose primary purposes are to advance the science, education and professional practice of medical physics. The AAPM has more than 8,000 members and is the principal organization of medical physicists in the United States. The AAPM will periodically define new practice guidelines for medical physics practice to help advance the science of medical physics and to improve the quality of service to patients throughout the United States. Existing medical physics practice guidelines will be reviewed for the purpose of revision or renewal, as appropriate, on their fifth anniversary or sooner. Each medical physics practice guideline represents a policy statement by the AAPM, has undergone a thorough consensus process in which it has been subjected to extensive review, and requires the approval of the Professional Council. The medical physics practice guidelines recognize that the safe and effective use of diagnostic and therapeutic radiology requires specific training, skills, and techniques, as described in each document. Reproduction or modification of the published practice guidelines and technical standards by those entities not providing these services is not authorized. The following terms are used in the AAPM practice guidelines: •Must and Must Not: Used to indicate that adherence to the recommendation is considered necessary to conform to this practice guideline. •Should and Should Not: Used to indicate a prudent practice to which exceptions may occasionally be made in appropriate circumstances. © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  19. A questionnaire study to derive information on the working environment, clinical training, use of ancillary staff and optimization of patient radiation dose within UK dental practice.

    PubMed

    Orafi, I; Rushton, V E

    2012-08-01

    To evaluate the working environment of GDPs and Endodontists and the methods used to optimize patient radiation dose. A total of 857 GDPs and 170 specialist Endodontists were contacted. The responders, 603 of the former and 132 of the latter, completed a questionnaire covering practitioner demographics, pattern of practice, the use of radiographic techniques and the optimization of dose. Chi-squared tests were used to compare groups at the P=0.05 level of significance. For nonparametric data, the Mann-Whitney U-test was employed. A response rate of 73% was achieved. Overall, 79.5% of endodontic specialists used film holders compared with 65.9% of GDPs (P=0.001). One hundred and thirty (98.5%) endodontists and 581 (96.3%) GDPs reported that they were well prepared or adequately prepared in radiographically assessing the presence of apical pathosis. The study found significant differences (P<0.001) between the use of digital radiography by specialist endodontists 93 (70.5%) compared with general dental practitioners 167 (27.7%). Significant differences (P=0.004) were also observed in the use of rectangular collimation between endodontic specialists 55 (42%) and GDPs 223 (37%). With regard to the use of film holders in diagnostic radiography, 105 (79.5%) of endodontic specialists employed these devices compared with 396 (65.7%) GDPs; this finding was significant (P=0.005). For working length estimation, significant differences (P=0.001) were noted in the use of a film holder between endodontic specialists 105 (79.5%) and GDPs 386 (64%). Both Endodontists and GDPs demonstrated compliance with guidelines relating to radiation protection being more significant amongst those clinicians working within specialist clinical practice. © 2012 International Endodontic Journal.

  20. Eye lens radiation exposure to interventional cardiologists: a retrospective assessment of cumulative doses.

    PubMed

    Jacob, Sophie; Donadille, Laurent; Maccia, Carlo; Bar, Olivier; Boveda, Serge; Laurier, Dominique; Bernier, Marie-Odile

    2013-03-01

    Radiation dose to the eye lens is a crucial issue for interventional cardiologists (ICs) who are exposed during the procedures they perform. This paper presents a retrospective assessment of the cumulative eye lens doses of ICs enrolled in the O'CLOC study for Occupational Cataracts and Lens Opacities in interventional Cardiology. Information on the workload in the catheterisation laboratory, radiation protection equipment, eye lens dose per procedure and dose reduction factors associated with eye-protective equipment were considered. For the 129 ICs at an average age of 51 who had worked for an average period of 22 years, the estimated cumulative eye lens dose ranged from 25 mSv to more than 1600 mSv; the mean ± SD was 423 ± 359 mSv. After several years of practice, without eye protection, ICs may exceed the new ICRP lifetime eye dose threshold of 500 mSv and be at high risk of developing early radiation-induced cataracts. Radiation protection equipment can reduce these doses and should be used routinely.

  1. OCCUPATIONAL RADIATION DOSES TO OPERATORS PERFORMING FLUOROSCOPICALLY-GUIDED PROCEDURES

    PubMed Central

    Kim, Kwang Pyo; Miller, Donald L.; de Gonzalez, Amy Berrington; Balter, Stephen; Kleinerman, Ruth A.; Ostroumova, Evgenia; Simon, Steven L.; Linet, Martha S.

    2012-01-01

    In the past 30 years, the numbers and types of fluoroscopically-guided (FG) procedures have increased dramatically. The objective of the present study is to provide estimated radiation doses to physician specialists, other than cardiologists, who perform FG procedures. We searched Medline to identify English-language journal articles reporting radiation exposures to these physicians. We then identified several primarily therapeutic FG procedures that met specific criteria: well-defined procedures for which there were at least five published reports of estimated radiation doses to the operator, procedures performed frequently in current medical practice, and inclusion of physicians from multiple medical specialties. These procedures were percutaneous nephrolithotomy (PCNL), vertebroplasty, orthopedic extremity nailing for treatment of fractures, biliary tract procedures, transjugular intrahepatic portosystemic shunt creation (TIPS), head/neck endovascular therapeutic procedures, and endoscopic retrograde cholangiopancreatography (ERCP). We abstracted radiation doses and other associated data, and estimated effective dose to operators. Operators received estimated doses per patient procedure equivalent to doses received by interventional cardiologists. The estimated effective dose per case ranged from 1.7 – 56μSv for PCNL, 0.1 – 101 μSv for vertebroplasty, 2.5 – 88μSv for orthopedic extremity nailing, 2.0 – 46μSv for biliary tract procedures, 2.5 – 74μSv for TIPS, 1.8 – 53μSv for head/neck endovascular therapeutic procedures, and 0.2 – 49μSv for ERCP. Overall, mean operator radiation dose per case measured over personal protective devices at different anatomic sites on the head and body ranged from 19 – 800 (median = 113) μSv at eye level, 6 – 1180 (median = 75)μSv at the neck, and 2 – 1600 (median = 302) μSv at the trunk. Operators’ hands often received greater doses than the eyes, neck or trunk. Large variations in operator doses

  2. LDL-C goal attainment in patients who remain on atorvastatin or switch to equivalent or non-equivalent doses of simvastatin: a retrospective matched cohort study in clinical practice.

    PubMed

    Rublee, Dale A; Burke, James P

    2010-03-01

    As clinical trials have shown the benefits of more intensive cholesterol control, treatment targets for low-density lipoprotein cholesterol (LDL-C) have decreased progressively. At the same time, physicians have been encouraged to contain costs by prescribing cheaper, generic statins for cholesterol management. To determine how these possibly conflicting goals are managed in clinical practice, we examined LDL-C control in patients switched from a potent, branded statin (atorvastatin) to a less potent, generic statin (simvastatin). Patients who switched from atorvastatin to simvastatin between July 2006 and January 2008 were retrospectively identified from a US medical and pharmacy claims database, and matched with controls remaining on atorvastatin. Outcomes measured were the number of switched patients receiving a simvastatin milligram dose>or=2 times their previous atorvastatin dose, changes in LDL-C levels, and percentage of patients achieving recommended LDL-C targets. All study variables were analyzed descriptively. After applying exclusion and inclusion criteria, 1048 patients who switched from atorvastatin to simvastatin and 1048 matched controls who remained on atorvastatin were included. Among the switchers, 379 (36%) received an inappropriately low dose of simvastatin (<2 times atorvastatin dose). In patients remaining on atorvastatin, mean LDL-C decreased from 105.7 mg/dL to 102.3 mg/dL after 44 weeks, whereas in switched patients, LDL-C remained similar, at 105.9 mg/dL on atorvastatin and 105.8 mg/dL on simvastatin. Before switching, when all patients were receiving atorvastatin, 67.4% of switchers and 69.9% of controls achieved recommended LDL-C targets. After switching, significantly fewer switchers than controls met LDL-C targets (69.1% vs 74.6%; P=0.005). However, among patients who switched to an equivalent dose of simvastatin (>or=2 times prior atorvastatin dose), similar proportions met LDL-C targets (72.8% vs 74.6% of controls; P=0.402), whereas

  3. Weight-based dosing in medication use: what should we know?

    PubMed Central

    Pan, Sheng-dong; Zhu, Ling-ling; Chen, Meng; Xia, Ping; Zhou, Quan

    2016-01-01

    correct. Effective weight-based dosing interventions include standardization of weight estimation, documentation and dosing determination, dosing chart, dosing protocol, order set, pharmacist participation, technological information, and educational measures. Conclusion Although dosing methods are specified in prescribing information for each drug and there are no principal pros and cons to be elaborated, this review of weight-based dosing strategy will enrich the knowledge of medication administration from the perspectives of safety, efficacy, and pharmacoeconomics, and will also provide research opportunities in clinical practice. Clinicians should be familiar with dosage and administration of the medication to be prescribed as well as the latest developments. PMID:27110105

  4. SU-F-T-340: Direct Editing of Dose Volume Histograms: Algorithms and a Unified Convex Formulation for Treatment Planning with Dose Constraints

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ungun, B; Stanford University School of Medicine, Stanford, CA; Fu, A

    2016-06-15

    Purpose: To develop a procedure for including dose constraints in convex programming-based approaches to treatment planning, and to support dynamic modification of such constraints during planning. Methods: We present a mathematical approach that allows mean dose, maximum dose, minimum dose and dose volume (i.e., percentile) constraints to be appended to any convex formulation of an inverse planning problem. The first three constraint types are convex and readily incorporated. Dose volume constraints are not convex, however, so we introduce a convex restriction that is related to CVaR-based approaches previously proposed in the literature. To compensate for the conservatism of this restriction,more » we propose a new two-pass algorithm that solves the restricted problem on a first pass and uses this solution to form exact constraints on a second pass. In another variant, we introduce slack variables for each dose constraint to prevent the problem from becoming infeasible when the user specifies an incompatible set of constraints. We implement the proposed methods in Python using the convex programming package cvxpy in conjunction with the open source convex solvers SCS and ECOS. Results: We show, for several cases taken from the clinic, that our proposed method meets specified constraints (often with margin) when they are feasible. Constraints are met exactly when we use the two-pass method, and infeasible constraints are replaced with the nearest feasible constraint when slacks are used. Finally, we introduce ConRad, a Python-embedded free software package for convex radiation therapy planning. ConRad implements the methods described above and offers a simple interface for specifying prescriptions and dose constraints. Conclusion: This work demonstrates the feasibility of using modifiable dose constraints in a convex formulation, making it practical to guide the treatment planning process with interactively specified dose constraints. This work was supported by

  5. Positive Emotion Correlates of Meditation Practice: A Comparison of Mindfulness Meditation and Loving-kindness Meditation.

    PubMed

    Fredrickson, Barbara L; Boulton, Aaron J; Firestine, Ann M; Van Cappellen, Patty; Algoe, Sara B; Brantley, Mary M; Kim, Sumi Loundon; Brantley, Jeffrey; Salzberg, Sharon

    2017-12-01

    The purpose of this study was to uncover the day-to-day emotional profiles and dose-response relations, both within-persons and between-persons, associated with initiating one of two meditation practices, either mindfulness meditation or loving-kindness meditation. Data were pooled across two studies of midlife adults ( N = 339) who were randomized to learn either mindfulness meditation or loving-kindness meditation in a six-week workshop. The duration and frequency of meditation practice was measured daily for nine weeks, commencing with the first workshop session. Likewise, positive and negative emotions were also measured daily, using the modified Differential Emotions Scale (Fredrickson, 2013). Analysis of daily emotion reports over the targeted nine-week period showed significant gains in positive emotions and no change in negative emotions, regardless of meditation type. Multilevel models also revealed significant dose-response relations between duration of meditation practice and positive emotions, both within-persons and between-persons. Moreover, the within-person dose-response relation was stronger for loving-kindness meditation than for mindfulness meditation. Similar dose-response relations were observed for the frequency of meditation practice. In the context of prior research on the mental and physical health benefits produced by subtle increases in day-to-day experiences of positive emotions, the present research points to evidence-based practices - both mindfulness meditation and loving-kindness meditation - that can improve emotional wellbeing.

  6. Phage therapy dosing: The problem(s) with multiplicity of infection (MOI).

    PubMed

    Abedon, Stephen T

    2016-01-01

    The concept of bacteriophage multiplicity of infection (MOI) - ratios of phages to bacteria - historically has been less easily applied than many phage workers would prefer or, perhaps, may be aware. Here, toward clarification of the concept, I discuss multiplicity of infection in terms of semantics, history, mathematics, pharmacology, and actual practice. For phage therapy and other biocontrol purposes it is desirable, especially, not to solely employ MOI to describe what phage quantities have been applied during dosing. Why? Bacterial densities can change between bacterial challenge and phage application, may not be easily determined immediately prior to phage dosing, and/or target bacterial populations may not be homogeneous with regard to phage access and thereby inconsistent in terms of what MOI individual bacteria experience. Toward experiment reproducibility and as practiced generally for antibacterial application, phage dosing instead should be described in terms of concentrations of formulations (phage titers) as well as volumes applied and, in many cases, absolute numbers of phages delivered. Such an approach typically will be far more desirable from a pharmacological perspective than solely indicating ratios of agents to bacteria. This essay was adapted, with permission, from an appendix of the 2011 monograph, Bacteriophages and Biofilms , Nova Science Publishers.

  7. Semi-Supervised Tripled Dictionary Learning for Standard-dose PET Image Prediction using Low-dose PET and Multimodal MRI

    PubMed Central

    Wang, Yan; Ma, Guangkai; An, Le; Shi, Feng; Zhang, Pei; Lalush, David S.; Wu, Xi; Pu, Yifei; Zhou, Jiliu; Shen, Dinggang

    2017-01-01

    Objective To obtain high-quality positron emission tomography (PET) image with low-dose tracer injection, this study attempts to predict the standard-dose PET (S-PET) image from both its low-dose PET (L-PET) counterpart and corresponding magnetic resonance imaging (MRI). Methods It was achieved by patch-based sparse representation (SR), using the training samples with a complete set of MRI, L-PET and S-PET modalities for dictionary construction. However, the number of training samples with complete modalities is often limited. In practice, many samples generally have incomplete modalities (i.e., with one or two missing modalities) that thus cannot be used in the prediction process. In light of this, we develop a semi-supervised tripled dictionary learning (SSTDL) method for S-PET image prediction, which can utilize not only the samples with complete modalities (called complete samples) but also the samples with incomplete modalities (called incomplete samples), to take advantage of the large number of available training samples and thus further improve the prediction performance. Results Validation was done on a real human brain dataset consisting of 18 subjects, and the results show that our method is superior to the SR and other baseline methods. Conclusion This work proposed a new S-PET prediction method, which can significantly improve the PET image quality with low-dose injection. Significance The proposed method is favorable in clinical application since it can decrease the potential radiation risk for patients. PMID:27187939

  8. Dose Adjustment for Normal Eating: A Role for the Expert Patient?

    PubMed Central

    2014-01-01

    The Dose Adjustment for Normal Eating (DAFNE) programme of intensive insulin therapy for type 1 diabetes provides a structured educational intervention to improve glycemic control, reduce hypoglycemia and improve quality of life. Enhancement of self-management skills is a key element of DAFNE and patients acquire detailed skills in insulin dose adjustment. Following DAFNE training, patients report improved confidence in their ability to manage their own insulin dosing, but generally still seek and require the assistance of health professionals when making substantial changes to their insulin regimens. Some DAFNE trained patients may be able to assist their peers in aspects of diabetes management within a group environment, but widespread introduction of the expert patient/peer educator role in the self-management of type 1 diabetes, in particular related to insulin dose management, would require formal and detailed evaluation, preferably in randomized controlled clinical trials, before being introduced into routine clinical practice. PMID:24851201

  9. Dynamically accumulated dose and 4D accumulated dose for moving tumors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li Heng; Li Yupeng; Zhang Xiaodong

    2012-12-15

    Purpose: The purpose of this work was to investigate the relationship between dynamically accumulated dose (dynamic dose) and 4D accumulated dose (4D dose) for irradiation of moving tumors, and to quantify the dose uncertainty induced by tumor motion. Methods: The authors established that regardless of treatment modality and delivery properties, the dynamic dose will converge to the 4D dose, instead of the 3D static dose, after multiple deliveries. The bounds of dynamic dose, or the maximum estimation error using 4D or static dose, were established for the 4D and static doses, respectively. Numerical simulations were performed (1) to prove themore » principle that for each phase, after multiple deliveries, the average number of deliveries for any given time converges to the total number of fractions (K) over the number of phases (N); (2) to investigate the dose difference between the 4D and dynamic doses as a function of the number of deliveries for deliveries of a 'pulsed beam'; and (3) to investigate the dose difference between 4D dose and dynamic doses as a function of delivery time for deliveries of a 'continuous beam.' A Poisson model was developed to estimate the mean dose error as a function of number of deliveries or delivered time for both pulsed beam and continuous beam. Results: The numerical simulations confirmed that the number of deliveries for each phase converges to K/N, assuming a random starting phase. Simulations for the pulsed beam and continuous beam also suggested that the dose error is a strong function of the number of deliveries and/or total deliver time and could be a function of the breathing cycle, depending on the mode of delivery. The Poisson model agrees well with the simulation. Conclusions: Dynamically accumulated dose will converge to the 4D accumulated dose after multiple deliveries, regardless of treatment modality. Bounds of the dynamic dose could be determined using quantities derived from 4D doses, and the mean dose

  10. Robust EM Continual Reassessment Method in Oncology Dose Finding

    PubMed Central

    Yuan, Ying; Yin, Guosheng

    2012-01-01

    The continual reassessment method (CRM) is a commonly used dose-finding design for phase I clinical trials. Practical applications of this method have been restricted by two limitations: (1) the requirement that the toxicity outcome needs to be observed shortly after the initiation of the treatment; and (2) the potential sensitivity to the prespecified toxicity probability at each dose. To overcome these limitations, we naturally treat the unobserved toxicity outcomes as missing data, and use the expectation-maximization (EM) algorithm to estimate the dose toxicity probabilities based on the incomplete data to direct dose assignment. To enhance the robustness of the design, we propose prespecifying multiple sets of toxicity probabilities, each set corresponding to an individual CRM model. We carry out these multiple CRMs in parallel, across which model selection and model averaging procedures are used to make more robust inference. We evaluate the operating characteristics of the proposed robust EM-CRM designs through simulation studies and show that the proposed methods satisfactorily resolve both limitations of the CRM. Besides improving the MTD selection percentage, the new designs dramatically shorten the duration of the trial, and are robust to the prespecification of the toxicity probabilities. PMID:22375092

  11. Gender Differences in Radiation Dose From Nuclear Cardiology Studies Across the World: Findings From the INCAPS Registry.

    PubMed

    Shi, Lynn; Dorbala, Sharmila; Paez, Diana; Shaw, Leslee J; Zukotynski, Katherine A; Pascual, Thomas N B; Karthikeyan, Ganesan; Vitola, João V; Better, Nathan; Bokhari, Nadia; Rehani, Madan M; Kashyap, Ravi; Dondi, Maurizio; Mercuri, Mathew; Einstein, Andrew J

    2016-04-01

    The aim of this study was to investigate gender-based differences in nuclear cardiology practice globally, with a particular focus on laboratory volume, radiation dose, protocols, and best practices. It is unclear whether gender-based differences exist in radiation exposure for nuclear cardiology procedures. In a large, multicenter, observational, cross-sectional study encompassing 7,911 patients in 65 countries, radiation effective dose was estimated for each examination. Patient-level best practices relating to radiation exposure were compared between genders. Analysis of covariance was used to determine any difference in radiation exposure according to gender, region, and the interaction between gender and region. Linear, logistic, and hierarchical regression models were developed to evaluate gender-based differences in radiation exposure and laboratory adherence to best practices. The study also included the United Nations Gender Inequality Index and Human Development Index as covariates in multivariable models. The proportion of myocardial perfusion imaging studies performed in women varied among countries; however, there was no significant correlation with the Gender Inequality Index. Globally, mean effective dose for nuclear cardiology procedures was only slightly lower in women (9.6 ± 4.5 mSv) than in men (10.3 ± 4.5 mSv; p < 0.001), with a difference of only 0.3 mSv in a multivariable model adjusting for patients' age and weight. Stress-only imaging was performed more frequently in women (12.5% vs. 8.4%; p < 0.001); however, camera-based dose reduction strategies were used less frequently in women (58.6% vs. 65.5%; p < 0.001). Despite significant worldwide variation in best practice use and radiation doses from nuclear cardiology procedures, only small differences were observed between genders worldwide. Regional variations noted in myocardial perfusion imaging use and radiation dose offer potential opportunities to address gender-related differences

  12. Gangs in Honduras: A Threat to National Security

    DTIC Science & Technology

    2012-03-22

    police, judiciary and political elites. In some parts of the country, “drug cartels act as de facto authority and there is evidence of a training camp...practical to politicians…to expect the military to solve the problem by force, nor is it practical for the military to plan and execute a purely military...Honduras: Tegucigalpa, National Defense College and El Salvador University, October 30, 2007), http://cdn.U.S.alnet.org/ tesis /files/osorio.pdf

  13. Review of proton pump inhibitors for the initial treatment of heartburn: is there a dose ceiling effect?

    PubMed

    Kushner, Pamela R; Peura, David A

    2011-05-01

    Proton pump inhibitors (PPIs) are widely used in clinical practice. However, concerns have been expressed about their long-term use, particularly with regard to bone health, Clostridium difficile infections, and drug interactions with platelet aggregation inhibitors. There has been limited guidance for clinicians concerning appropriate dose selection of PPIs for the initial treatment of heartburn. This review explored whether published clinical trials provide evidence of a ceiling above which higher PPI doses do not provide additional clinical benefit over the lowest approved dose. All articles of randomized, controlled clinical trials in nonerosive gastroesophageal reflux disease (GERD) in which the effects of two or more doses of the same PPI on symptomatic relief of heartburn were quantified as a study endpoint were identified and analyzed through PubMed searches up to the end of September 2010. The majority of trials evaluated provided no evidence that higher PPI doses were superior to the lowest approved dose for the initial treatment of heartburn. There were no clinically relevant findings with respect to dose dependence and safety outcomes in these studies. Efficacy outcomes from the trials suggest there may be a dose ceiling effect and highlight the need for further research on the use of the lowest effective PPI doses as an appropriate strategy in the initial treatment of uncomplicated heartburn. Observational studies and some meta-analyses have suggested that long-term PPI pharmacotherapy might be associated with safety concerns, which necessitate the periodic evaluation of therapeutic benefit in terms of symptom resolution and regimen tolerability. However, evidence to date suggests that use of the lowest effective dose for the indication is not associated with significant adverse events, particularly in the short term. Clinical practice suggests that patients requiring long-term treatment should be maintained on the lowest dose necessary to control

  14. Pharmacokinetic studies in children: recommendations for practice and research.

    PubMed

    Barker, Charlotte I S; Standing, Joseph F; Kelly, Lauren E; Hanly Faught, Lauren; Needham, Allison C; Rieder, Michael J; de Wildt, Saskia N; Offringa, Martin

    2018-04-19

    Optimising the dosing of medicines for neonates and children remains a challenge. The importance of pharmacokinetic (PK) and pharmacodynamic (PD) research is recognised both in medicines regulation and paediatric clinical pharmacology, yet there remain barriers to undertaking high-quality PK and PD studies. While these studies are essential in understanding the dose-concentration-effect relationship and should underpin dosing recommendations, this review examines how challenges affecting the design and conduct of paediatric pharmacological studies can be overcome using targeted pharmacometric strategies. Model-based approaches confer benefits at all stages of the drug life-cycle, from identifying the first dose to be used in children, to clinical trial design, and optimising the dosing regimens of older, off-patent medications. To benefit patients, strategies to ensure that new PK, PD and trial data are incorporated into evidence-based dosing recommendations are needed. This review summarises practical strategies to address current challenges, particularly the use of model-based (pharmacometric) approaches in study design and analysis. Recommendations for practice and directions for future paediatric pharmacological research are given, based on current literature and our joint international experience. Success of PK research in children requires a robust infrastructure, with sustainable funding mechanisms at its core, supported by political and regulatory initiatives, and international collaborations. There is a unique opportunity to advance paediatric medicines research at an unprecedented pace, bringing the age of evidence-based paediatric pharmacotherapy into sight. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  15. Estimation Of Organ Doses From Solar Particle Events For Future Space Exploration Missions

    NASA Technical Reports Server (NTRS)

    Kim, Myung-Hee; Cucinotta, Francis A.

    2006-01-01

    Radiation protection practices define the effective dose as a weighted sum of equivalent dose over major organ sites for radiation cancer risks. Since a crew personnel dosimeter does not make direct measurement of the effective dose, it has been estimated with skin-dose measurements and radiation transport codes for ISS and STS missions. If sufficient protection is not provided near solar maximum, the radiation risk can be significant due to exposure to sporadic solar particle events (SPEs) as well as to the continuous galactic cosmic radiation (GCR) on future exploratory-class and long-duration missions. For accurate estimates of overall fatal cancer risks from SPEs, the specific doses at various blood forming organs (BFOs) were considered, because proton fluences and doses vary considerably across marrow regions. Previous estimates of BFO doses from SPEs have used an average body-shielding distribution for the bone marrow based on the computerized anatomical man model (CAM). With the development of an 82-point body-shielding distribution at BFOs, the mean and variance of SPE doses in the major active marrow regions (head and neck, chest, abdomen, pelvis and thighs) will be presented. Consideration of the detailed distribution of bone marrow sites is one of many requirements to improve the estimation of effective doses for radiation cancer risks.

  16. Standard dose versus low dose non-vitamin K antagonist oral anticoagulants in Asian patients with atrial fibrillation: A meta-analysis of contemporary randomized controlled trials.

    PubMed

    Wang, Kang-Ling; Giugliano, Robert P; Goto, Shinya; Chiu, Chun-Chih; Lin, Chun-Yi; Lai, En-Yu; Chiang, Chern-En

    2016-12-01

    Although randomized controlled trials (RCTs) indicated that standard dose non-vitamin K antagonist oral anticoagulants (NOACs) were more compelling, low dose NOACs are commonly used in clinical practice in Asia. The purpose of this study was to assess the relative therapeutic benefit and risk of standard dose vs low dose NOACs in Asian patients enrolled in contemporary RCTs. We performed a prespecified meta-analysis of 3155 Asian patients with NOACs in the RE-LY (Randomized Evaluation of Long-Term Anticoagulation Therapy) and ENGAGE AF-TIMI 48 (Effective Anticoagulation with Factor Xa Next Generation in Atrial Fibrillation-Thrombolysis in Myocardial Infarction 48) trials. Efficacy and safety with standard dose vs low dose NOACs were compared by risk ratios (RRs) and 95% confidence intervals (CIs) in a random-effects model. An evidence network incorporating additional Asian patients from ROCKET AF, J- ROCKET AF, and ARISTOTLE was constructed with the Bayesian method. Risks of stroke or systemic embolism and ischemic stroke were significantly reduced with standard dose vs low dose NOACs (RR 0.62, 95% CI 0.45-0.85; and RR 0.55, 95% CI 0.38-0.79, respectively). Rates of major, intracranial, and life-threatening bleeding with 2 dosing regimens were broadly similar (RR 1.31, 95% CI 0.74-2.33; RR 1.54, 95% CI 0.72-3.30; and RR 1.49, 95% CI 0.87-2.55, respectively). Absolute rates of all-cause mortality and the net clinical outcome with standard dose NOACs were lower but not statistically significant (absolute reduction 0.4% per year and 1.1% per year, respectively). Network meta-analyses demonstrated that standard dose NOACs had the most favorable risk-benefit profile among oral anticoagulants. In Asian patients, standard dose NOACs represent a more appealing therapeutic option than low dose NOACs, with a significant reduction in ischemic stroke without an excess of major bleeding. Copyright © 2016 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  17. Investigation of dose characteristics in three-dimensional MAGAT-type polymer gel dosimetry with MSE MR imaging

    NASA Astrophysics Data System (ADS)

    Lee, Jason J. S.; Tsai, Chia-Jung; Lo, Man-Kuok; Huang, Yung-Hui; Chen, Chien-Chuan; Wu, Jay; Tyan, Yeu-Sheng; Wu, Tung-Hsin

    2008-05-01

    A new type of normoxic polymer gel dosimeter, named MAGAT responses well to absorbed dose even when manufacturing in the presence of normal levels of oxygen. The aim of this study was to evaluate dose response, diffusion effect and cumulated dose response under multiple fractional irradiations of the MAGAT gel dosimeter using Multiple Spin-Echo (MSE) Magnetic Resonance (MR) sequence. Dose response was performed by irradiating MAGAT-gel-filled testing vials with a 6 MV linear accelerator and a linear relationship was present with doses from 0 to 6 Gy, but gradually, a bi-exponential function result was obtained with given doses up to 20 Gy. No significant difference in dose response was present between single and cumulated doses (p > 0.05). For study of diffusion effect, edge sharpness of the R2 map imaging between two split doses was smaller than 1 cm of dose profile penumbra between 20% and 80%. In conclusion, the MAGAT polymer gel dosimeter with MSE MR imaging is a promising method for dose verification in clinical radiation therapy practice.

  18. Spot scanning proton therapy plan assessment: design and development of a dose verification application for use in routine clinical practice

    NASA Astrophysics Data System (ADS)

    Augustine, Kurt E.; Walsh, Timothy J.; Beltran, Chris J.; Stoker, Joshua B.; Mundy, Daniel W.; Parry, Mark D.; Bues, Martin; Fatyga, Mirek

    2016-04-01

    The use of radiation therapy for the treatment of cancer has been carried out clinically since the late 1800's. Early on however, it was discovered that a radiation dose sufficient to destroy cancer cells can also cause severe injury to surrounding healthy tissue. Radiation oncologists continually strive to find the perfect balance between a dose high enough to destroy the cancer and one that avoids damage to healthy organs. Spot scanning or "pencil beam" proton radiotherapy offers another option to improve on this. Unlike traditional photon therapy, proton beams stop in the target tissue, thus better sparing all organs beyond the targeted tumor. In addition, the beams are far narrower and thus can be more precisely "painted" onto the tumor, avoiding exposure to surrounding healthy tissue. To safely treat patients with proton beam radiotherapy, dose verification should be carried out for each plan prior to treatment. Proton dose verification systems are not currently commercially available so the Department of Radiation Oncology at the Mayo Clinic developed its own, called DOSeCHECK, which offers two distinct dose simulation methods: GPU-based Monte Carlo and CPU-based analytical. The three major components of the system include the web-based user interface, the Linux-based dose verification simulation engines, and the supporting services and components. The architecture integrates multiple applications, libraries, platforms, programming languages, and communication protocols and was successfully deployed in time for Mayo Clinic's first proton beam therapy patient. Having a simple, efficient application for dose verification greatly reduces staff workload and provides additional quality assurance, ultimately improving patient safety.

  19. Correlation between prescribed daily dose, seizure freedom and defined daily dose in antiepileptic drug treatment.

    PubMed

    Horváth, László; Fekete, Klára; Márton, Sándor; Fekete, István

    2017-04-01

    Background Although defined daily doses (DDD) for antiepileptic drugs (AED) have been assigned only in combination therapy, based on the literature, most patients take them in monotherapy. Furthermore, discrepancies between DDD and prescribed daily dose (PDD) were observed. Objective First, to determine PDDs of AEDs and to reveal PDD/DDD ratio among seizure free versus not seizure free patients in everyday clinical practice. Second, to test the applicability of 75% cut-off of DDD to achieve seizure freedom. Furthermore, to find out what factors might influence PDD. Setting Outpatient data files at a Hungarian university hospital were studied. Methods A retrospective, 20-year cross-sectional database was compiled from 1282 epileptic outpatients' files. Main outcome measure Seizure freedom and PDD were used as outcome measures. Results The mean DDD% of all prescribed AEDs increased steadily from monotherapy, through bitherapy towards polytherapy (p < 0.0001). Most seizure free patients took AEDs in doses in the range of ≤75% of DDDs in monotherapy and bitherapy. Older AEDs (carbamazepine and valproate) were given in a significantly higher mean dose in bitherapy in the seizure free group. Among the newer types, only levetiracetam and lamotrigine had a significantly higher DDD% in mono-, bi-, and polytherapy. Confirmed by logistic regression analysis, gender, age, type of epilepsy, and number of AEDs had a significant impact on the value of 75% DDD. Conclusion No significant unfavourable impact of the lower ratio of PDD/DDD on the outcome of achieving seizure freedom has been confirmed. As a measure of seizure freedom, 75% of DDD may be used, although individual therapy must be emphasised. Precisely quantified DDD would provide a more accurate calculation of other derived values.

  20. The Legacy Effect: Understanding How Segregation and Environmental Injustice Unfold over Time in Baltimore

    Treesearch

    Morgan Grove; Laura Ogden; Steward Pickett; Chris Boone; Geoff Buckley; Dexter H. Locke; Charlie Lord; Billy Hall

    2018-01-01

    Legacies of social and environmental injustices can leave an imprint on the present and constrain transitions for more sustainable futures. In this article, we ask this question: What is the relationship of environmental inequality and histories of segregation? The answer for Baltimore is complex, where past practices of de jure and de facto segregation have created...

  1. National survey on dose data analysis in computed tomography.

    PubMed

    Heilmaier, Christina; Treier, Reto; Merkle, Elmar Max; Alkhadi, Hatem; Weishaupt, Dominik; Schindera, Sebastian

    2018-05-28

    A nationwide survey was performed assessing current practice of dose data analysis in computed tomography (CT). All radiological departments in Switzerland were asked to participate in the on-line survey composed of 19 questions (16 multiple choice, 3 free text). It consisted of four sections: (1) general information on the department, (2) dose data analysis, (3) use of a dose management software (DMS) and (4) radiation protection activities. In total, 152 out of 241 Swiss radiological departments filled in the whole questionnaire (return rate, 63%). Seventy-nine per cent of the departments (n = 120/152) analyse dose data on a regular basis with considerable heterogeneity in the frequency (1-2 times per year, 45%, n = 54/120; every month, 35%, n = 42/120) and method of analysis. Manual analysis is carried out by 58% (n = 70/120) compared with 42% (n = 50/120) of departments using a DMS. Purchase of a DMS is planned by 43% (n = 30/70) of the departments with manual analysis. Real-time analysis of dose data is performed by 42% (n = 21/50) of the departments with a DMS; however, residents can access the DMS in clinical routine only in 20% (n = 10/50) of the departments. An interdisciplinary dose team, which among other things communicates dose data internally (63%, n = 76/120) and externally, is already implemented in 57% (n = 68/120) departments. Swiss radiological departments are committed to radiation safety. However, there is high heterogeneity among them regarding the frequency and method of dose data analysis as well as the use of DMS and radiation protection activities. • Swiss radiological departments are committed to and interest in radiation safety as proven by a 63% return rate of the survey. • Seventy-nine per cent of departments analyse dose data on a regular basis with differences in the frequency and method of analysis: 42% use a dose management software, while 58% currently perform manual dose data analysis. Of the latter, 43% plan to buy a dose

  2. The impact of a good practice manual on professional practice associated with psychotropic PRN in acute mental health wards: an exploratory study.

    PubMed

    Baker, J A; Lovell, K; Harris, N

    2008-10-01

    As required or pro re nata (PRN) psychotropic medicines are frequently used in acute mental health wards. PRN is known to contribute to polypharmacy and high doses of antipsychotic medication. Few studies have attempted to improve clinician's use of these potentially harmful drugs. The objectives of the study were to determine the impact and acceptability of a good practice manual on prescribing and administration practices of PRN psychotropic medication in acute mental health wards. The study used a pre-post exploratory design with two acute mental health wards in the NW of England. Over the total trial period of 10 weeks, 28 of 35 patients received 484 doses of PRN. Patients had a mean of 3.6 prescriptions of 14 different PRN medications in 34 different dose combinations prescribed. Medication errors beyond poor quality of prescribing occurred in 23 of the 35 patients (65.7%). Prescription quality improved following the introduction of the intervention but quality of nursing notes reduced. Acceptability of the manual to both nursing and medical staff was high. The introduction of the manual appeared to influence some of the practices associated with the prescribing and administration of PRN psychotropic medications. Further, larger, more robust studies are required in this area. In particular research is required to identify the reasons why professionals continue to rely so heavily on using PRN medication.

  3. Improved Consistency in Dosing Anti-Tuberculosis Drugs in Taipei, Taiwan

    PubMed Central

    Chiang, Chen-Yuan; Yu, Ming-Chih; Shih, Hsiu-Chen; Yen, Muh-Yong; Hsu, Yu-Ling; Yang, Shiang-Lin; Lin, Tao-Ping; Bai, Kuan-Jen

    2012-01-01

    Background It was reported that 35.5% of tuberculosis (TB) cases reported in 2003 in Taipei City had no recorded pre-treatment body weight and that among those who had, inconsistent dosing of anti-TB drugs was frequent. Taiwan Centers for Disease Control (CDC) have taken actions to strengthen dosing of anti-TB drugs among general practitioners. Prescribing practices of anti-TB drugs in Taipei City in 2007–2010 were investigated to assess whether interventions on dosing were effective. Methodology/Principal Findings Lists of all notified culture positive TB cases in 2007–2010 were obtained from National TB Registry at Taiwan CDC. A medical audit of TB case management files was performed to collect pretreatment body weight and regimens prescribed at commencement of treatment. Dosages prescribed were compared with dosages recommended. The proportion of patients with recorded pre-treatment body weight was 64.5% in 2003, which increased to 96.5% in 2007–2010 (p<0.001). The proportion of patients treated with consistent dosing of a 3-drug fixed-dose combination (FDC) increased from 73.9% in 2003 to 87.7% in 2007–2010 (p<0.001), and that for 2-drug FDC from 76.0% to 86.1% (p = 0.024), for rifampicin (RMP) from 62.8% to 85.5% (p<0.001), and for isoniazid from 87.8% to 95.3% (p<0.001). In 2007–2010, among 2917 patients treated with either FDCs or RMP in single-drug preparation, the dosage of RMP was adequate (8–12 mg/kg) in 2571(88.1%) patients, too high in 282(9.7%), too low in 64(2.2%). In multinomial logistic regression models, factors significantly associated with adequate dosage of RMP were body weight and preparations of RMP. Patients weighting <40kg (relative risk ratio (rrr) 6010.5, 95% CI 781.1–46249.7) and patients weighting 40–49 kg (rrr 1495.3, 95% CI 200.6–11144.6) were more likely to receive higher-than-recommended dose of RMP. Conclusions/Significance Prescribing practice in the treatment of TB in Taipei City has remarkably improved

  4. Improved consistency in dosing anti-tuberculosis drugs in Taipei, Taiwan.

    PubMed

    Chiang, Chen-Yuan; Yu, Ming-Chih; Shih, Hsiu-Chen; Yen, Muh-Yong; Hsu, Yu-Ling; Yang, Shiang-Lin; Lin, Tao-Ping; Bai, Kuan-Jen

    2012-01-01

    It was reported that 35.5% of tuberculosis (TB) cases reported in 2003 in Taipei City had no recorded pre-treatment body weight and that among those who had, inconsistent dosing of anti-TB drugs was frequent. Taiwan Centers for Disease Control (CDC) have taken actions to strengthen dosing of anti-TB drugs among general practitioners. Prescribing practices of anti-TB drugs in Taipei City in 2007-2010 were investigated to assess whether interventions on dosing were effective. Lists of all notified culture positive TB cases in 2007-2010 were obtained from National TB Registry at Taiwan CDC. A medical audit of TB case management files was performed to collect pretreatment body weight and regimens prescribed at commencement of treatment. Dosages prescribed were compared with dosages recommended. The proportion of patients with recorded pre-treatment body weight was 64.5% in 2003, which increased to 96.5% in 2007-2010 (p<0.001). The proportion of patients treated with consistent dosing of a 3-drug fixed-dose combination (FDC) increased from 73.9% in 2003 to 87.7% in 2007-2010 (p<0.001), and that for 2-drug FDC from 76.0% to 86.1% (p = 0.024), for rifampicin (RMP) from 62.8% to 85.5% (p<0.001), and for isoniazid from 87.8% to 95.3% (p<0.001). In 2007-2010, among 2917 patients treated with either FDCs or RMP in single-drug preparation, the dosage of RMP was adequate (8-12 mg/kg) in 2571(88.1%) patients, too high in 282(9.7%), too low in 64(2.2%). In multinomial logistic regression models, factors significantly associated with adequate dosage of RMP were body weight and preparations of RMP. Patients weighting <40 kg (relative risk ratio (rrr) 6010.5, 95% CI 781.1-46249.7) and patients weighting 40-49 kg (rrr 1495.3, 95% CI 200.6-11144.6) were more likely to receive higher-than-recommended dose of RMP. Prescribing practice in the treatment of TB in Taipei City has remarkably improved after health authorities implemented a series of interventions.

  5. Online Training in Mind-Body Therapies: Different Doses, Long-term Outcomes.

    PubMed

    Kemper, Kathi J; Rao, Nisha; Gascon, Gregg; Mahan, John D

    2017-10-01

    There is a high rate of burnout among health professionals, driving diverse attempts to promote resilience and well-being to counter this trend. The purpose of this project was to assess the dose-response relationship between the number of hours of online mind-body skills training for health professionals and relevant outcomes a year later. Among 1438 registrants for online training (including up to 12 hours of training on mind-body practices) between December 2013 and November 2015, we analyzed responses from the first 10% who responded to an anonymous online survey between December 1, 2015 and February 1, 2016. Questions included the type and frequency of mind-body practice in the past 30 days and whether the online training had any impact on personal life or professional practice. Standardized measures were used to assess stress, mindfulness, confidence in providing compassionate care, and burnout. The 149 respondents represented a variety of ages and health professions; 55% completed one or more mind-body training modules an average of 14 months previously. Most (78%) engaged in one or more mind-body practices in the 30 days before the survey; 79% reported changes in self-care and 71% reported changes in the care of others as a result of participating. Increasing number of hours of training were significantly associated with practicing mind-body skills more frequently; increasing practice frequency was associated with less stress and burnout, which were associated with missing less work. Greater practice frequency was also associated with improvements in stress, mindfulness, and resilience, which were associated with increased confidence in providing compassionate care. Online training in mind-body therapies is associated with changes in self-reported behavior one year later; increasing doses of training are associated with more frequent practice which is associated with less stress, burnout, and missing work, and higher levels of mindfulness, resilience, and

  6. Epidural analgesia practices for labour: results of a 2005 national survey in Ireland.

    PubMed

    Fanning, Rebecca A; Briggs, Liam P; Carey, Michael F

    2009-03-01

    The last 25 years have seen changes in the management of epidural analgesia for labour, including the advent of low-dose epidural analgesia, the development of new local anaesthetic agents, various regimes for maintaining epidural analgesia and the practice of combined spinal-epidural analgesia. We conducted a survey of Irish obstetric anaesthetists to obtain information regarding the conduct and management of obstetric epidural analgesia in Ireland in 2005. The specific objective of this survey was to discover whether new developments in obstetric anaesthesia have been incorporated into clinical practice. A postal survey was sent to all anaesthetists with a clinical commitment for obstetric anaesthesia in the sites approved for training by the College of Anaesthetists, Ireland. Fifty-three per cent of anaesthetists surveyed responded. The majority of anaesthetists (98%) use low-dose epidural analgesia for the maintenance of analgesia. Only 11% use it for test-dosing and 32% for the induction of analgesia. The combined spinal-epidural analgesia method is used by 49%, but two-thirds of those who use it perform fewer than five per month. Patient-controlled epidural analgesia was in use at only one site. It appears that Irish obstetric anaesthetists have adopted the low-dose epidural analgesia trend for the maintenance of labour analgesia. This practice is not as widespread, however, for test dosing, the induction of analgesia dose or in the administration of intermittent epidural boluses to maintain analgesia when higher concentrations are used. Since its introduction in 2000, levobupivacaine has become the most popular local anaesthetic agent.

  7. Prospective Evaluation of a Model-Based Dosing Regimen for Amikacin in Preterm and Term Neonates in Clinical Practice

    PubMed Central

    De Cock, R. F. W.; Allegaert, K.; Vanhaesebrouck, S.; Danhof, M.; Knibbe, C. A. J.

    2015-01-01

    Based on a previously derived population pharmacokinetic model, a novel neonatal amikacin dosing regimen was developed. The aim of the current study was to prospectively evaluate this dosing regimen. First, early (before and after second dose) therapeutic drug monitoring (TDM) observations were evaluated for achieving target trough (<3 mg/liter) and peak (>24 mg/liter) levels. Second, all observed TDM concentrations were compared with model-predicted concentrations, whereby the results of a normalized prediction distribution error (NPDE) were considered. Subsequently, Monte Carlo simulations were performed. Finally, remaining causes limiting amikacin predictability (i.e., prescription errors and disease characteristics of outliers) were explored. In 579 neonates (median birth body weight, 2,285 [range, 420 to 4,850] g; postnatal age 2 days [range, 1 to 30 days]; gestational age, 34 weeks [range, 24 to 41 weeks]), 90.5% of the observed early peak levels reached 24 mg/liter, and 60.2% of the trough levels were <3 mg/liter (93.4% ≤5 mg/liter). Observations were accurately predicted by the model without bias, which was confirmed by the NPDE. Monte Carlo simulations showed that peak concentrations of >24 mg/liter were reached at steady state in almost all patients. Trough values of <3 mg/liter at steady state were documented in 78% to 100% and 45% to 96% of simulated cases with and without ibuprofen coadministration, respectively; suboptimal trough levels were found in patients with postnatal age <14 days and current weight of >2,000 g. Prospective evaluation of a model-based neonatal amikacin dosing regimen resulted in optimized peak and trough concentrations in almost all patients. Slightly adapted dosing for patient subgroups with suboptimal trough levels was proposed. This model-based approach improves neonatal dosing individualization. PMID:26248375

  8. DICOM organ dose does not accurately represent calculated dose in mammography

    NASA Astrophysics Data System (ADS)

    Suleiman, Moayyad E.; Brennan, Patrick C.; McEntee, Mark F.

    2016-03-01

    This study aims to analyze the agreement between the mean glandular dose estimated by the mammography unit (organ dose) and mean glandular dose calculated using Dance et al published method (calculated dose). Anonymised digital mammograms from 50 BreastScreen NSW centers were downloaded and exposure information required for the calculation of dose was extracted from the DICOM header along with the organ dose estimated by the system. Data from quality assurance annual tests for the included centers were collected and used to calculate the mean glandular dose for each mammogram. Bland-Altman analysis and a two-tailed paired t-test were used to study the agreement between calculated and organ dose and the significance of any differences. A total of 27,869 dose points from 40 centers were included in the study, mean calculated dose and mean organ dose (+/- standard deviation) were 1.47 (+/-0.66) and 1.38 (+/-0.56) mGy respectively. A statistically significant 0.09 mGy bias (t = 69.25; p<0.0001) with 95% limits of agreement between calculated and organ doses ranging from -0.34 and 0.52 were shown by Bland-Altman analysis, which indicates a small yet highly significant difference between the two means. The use of organ dose for dose audits is done at the risk of over or underestimating the calculated dose, hence, further work is needed to identify the causal agents for differences between organ and calculated doses and to generate a correction factor for organ dose.

  9. Estimating thyroid dose in pediatric CT exams from surface dose measurement

    NASA Astrophysics Data System (ADS)

    Al-Senan, Rani; Mueller, Deborah L.; Hatab, Mustapha R.

    2012-07-01

    The purpose of this study was to investigate the possibility of estimating pediatric thyroid doses from CT using surface neck doses. Optically stimulated luminescence dosimeters were used to measure the neck surface dose of 25 children ranging in ages between one and three years old. The neck circumference for each child was measured. The relationship between obtained surface doses and thyroid dose was studied using acrylic phantoms of various sizes and with holes of different depths. The ratios of hole-to-surface doses were used to convert patients' surface dose to thyroid dose. ImPACT software was utilized to calculate thyroid dose after applying the appropriate age correction factors. A paired t-test was performed to compare thyroid doses from our approach and ImPACT. The ratio of thyroid to surface dose was found to be 1.1. Thyroid doses ranged from 20 to 80 mGy. Comparison showed no statistical significance (p = 0.18). In addition, the average of surface dose variation along the z-axis in helical scans was studied and found to range between 5% (in 10 cm diameter phantom/24 mm collimation/pitch 1.0) and 8% (in 16 cm diameter phantom/12 mm collimation/pitch 0.7). We conclude that surface dose is an acceptable predictor for pediatric thyroid dose from CT. The uncertainty due to surface dose variability may be reduced if narrower collimation is used with a pitch factor close to 1.0. Also, the results did not show any effect of thyroid depth on the measured dose.

  10. The impact of inter-fraction dose variations on biological equivalent dose (BED): the concept of equivalent constant dose.

    PubMed

    Zavgorodni, S

    2004-12-07

    Inter-fraction dose fluctuations, which appear as a result of setup errors, organ motion and treatment machine output variations, may influence the radiobiological effect of the treatment even when the total delivered physical dose remains constant. The effect of these inter-fraction dose fluctuations on the biological effective dose (BED) has been investigated. Analytical expressions for the BED accounting for the dose fluctuations have been derived. The concept of biological effective constant dose (BECD) has been introduced. The equivalent constant dose (ECD), representing the constant physical dose that provides the same cell survival fraction as the fluctuating dose, has also been introduced. The dose fluctuations with Gaussian as well as exponential probability density functions were investigated. The values of BECD and ECD calculated analytically were compared with those derived from Monte Carlo modelling. The agreement between Monte Carlo modelled and analytical values was excellent (within 1%) for a range of dose standard deviations (0-100% of the dose) and the number of fractions (2 to 37) used in the comparison. The ECDs have also been calculated for conventional radiotherapy fields. The analytical expression for the BECD shows that BECD increases linearly with the variance of the dose. The effect is relatively small, and in the flat regions of the field it results in less than 1% increase of ECD. In the penumbra region of the 6 MV single radiotherapy beam the ECD exceeded the physical dose by up to 35%, when the standard deviation of combined patient setup/organ motion uncertainty was 5 mm. Equivalently, the ECD field was approximately 2 mm wider than the physical dose field. The difference between ECD and the physical dose is greater for normal tissues than for tumours.

  11. Technical Note: scuda: A software platform for cumulative dose assessment.

    PubMed

    Park, Seyoun; McNutt, Todd; Plishker, William; Quon, Harry; Wong, John; Shekhar, Raj; Lee, Junghoon

    2016-10-01

    Accurate tracking of anatomical changes and computation of actually delivered dose to the patient are critical for successful adaptive radiation therapy (ART). Additionally, efficient data management and fast processing are practically important for the adoption in clinic as ART involves a large amount of image and treatment data. The purpose of this study was to develop an accurate and efficient Software platform for CUmulative Dose Assessment (scuda) that can be seamlessly integrated into the clinical workflow. scuda consists of deformable image registration (DIR), segmentation, dose computation modules, and a graphical user interface. It is connected to our image PACS and radiotherapy informatics databases from which it automatically queries/retrieves patient images, radiotherapy plan, beam data, and daily treatment information, thus providing an efficient and unified workflow. For accurate registration of the planning CT and daily CBCTs, the authors iteratively correct CBCT intensities by matching local intensity histograms during the DIR process. Contours of the target tumor and critical structures are then propagated from the planning CT to daily CBCTs using the computed deformations. The actual delivered daily dose is computed using the registered CT and patient setup information by a superposition/convolution algorithm, and accumulated using the computed deformation fields. Both DIR and dose computation modules are accelerated by a graphics processing unit. The cumulative dose computation process has been validated on 30 head and neck (HN) cancer cases, showing 3.5 ± 5.0 Gy (mean±STD) absolute mean dose differences between the planned and the actually delivered doses in the parotid glands. On average, DIR, dose computation, and segmentation take 20 s/fraction and 17 min for a 35-fraction treatment including additional computation for dose accumulation. The authors developed a unified software platform that provides accurate and efficient monitoring of

  12. Use of Subcutaneous and Intraperitoneal Administration Methods to Facilitate Cassette Dosing in Microdialysis Studies in Rats.

    PubMed

    Durk, Matthew R; Deshmukh, Gauri; Valle, Nicole; Ding, Xiao; Liederer, Bianca M; Liu, Xingrong

    2018-07-01

    Microdialysis is a powerful technique allowing for real-time measurement of unbound drug concentrations in brain interstitial fluid in conscious animals. Use of microdialysis in drug discovery is limited by high resource requirement and low throughput, but this may be improved by cassette dosing. Administering multiple compounds intravenously of diverse physiochemical properties, it is often very challenging and time consuming to identify a vehicle that can dissolve all of the compounds. To overcome this limitation, the present study explores the possibility of administering a cassette dose of nine diverse compounds (carbamazepine, citalopram, desmethylclozapine, diphenhydramine, gabapentin, metoclopramide, naltrexone, quinidine, and risperidone) in suspension, rather than in solution, by intraperitoneal and subcutaneous routes, and determining if this is a viable option for assessing blood-brain barrier penetration in microdialysis studies. Repeated hourly subcutaneous dosing during the 6-hour microdialysis study allowed for the best attainment of distributional equilibrium between brain and plasma, resulting in less than a 2-fold difference in the unbound brain to unbound plasma concentration ratio for the cassette dosing method versus discrete dosing. Both subcutaneous and intraperitoneal repeated dosing can provide a more practical substitute for intravenous dosing in determining brain penetration of a cassette of diverse compounds in brain microdialysis studies. The results from the present study demonstrate that dosing compounds in suspension represents a practical approach to eliminating the technical challenge and labor-intensive step of preparation of solutions of a mixture of compounds and will enable the use of the cassette brain microdialysis method in a central nervous system drug discovery setting. Copyright © 2018 by The American Society for Pharmacology and Experimental Therapeutics.

  13. Clinical application of the OneDose Patient Dosimetry System for total body irradiation.

    PubMed

    Best, S; Ralston, A; Suchowerska, N

    2005-12-21

    The OneDose Patient Dosimetry System (Sicel Technologies) is a new dosimeter based on metal oxide semiconductor field-effect transistor technology and designed for the in vivo measurement of patient dose during radiotherapy. In vivo dosimetry for total body irradiation (TBI) is challenging due to the extended treatment distance, low dose rates and beam spoilers. Phantom results confirm the suitability of the dosimeter for TBI in terms of inherent build-up, post-irradiation fading, accuracy, reproducibility, linearity and temperature dependence. Directional dependence is significant and should be taken into account. The OneDose dosimeters were also trialed in vivo for two TBI patients and the dose measured compared to conventional dosimeter measurements using an ionization chamber and thermoluminescent dosimeters (TLD), with agreement to within 2.2% and 3.9%, respectively. Phantom and patient results confirm that the OneDose patient dosimetry system is a practical and convenient alternative to TLDs for TBI in vivo dosimetry. For increased confidence in results with this dosimeter, we recommend that two dosimeters be used for each site of interest.

  14. Methylphenidate dose optimization for ADHD treatment: review of safety, efficacy, and clinical necessity

    PubMed Central

    Huss, Michael; Duhan, Praveen; Gandhi, Preetam; Chen, Chien-Wei; Spannhuth, Carsten; Kumar, Vinod

    2017-01-01

    Attention-deficit/hyperactivity disorder (ADHD) is a chronic psychiatric disorder characterized by hyperactivity and/or inattention and is often associated with a substantial impact on psychosocial functioning. Methylphenidate (MPH), a central nervous system stimulant, is commonly used for pharmacological treatment of adults and children with ADHD. Current practice guidelines recommend optimizing MPH dosage to individual patient needs; however, the clinical benefits of individual dose optimization compared with fixed-dose regimens remain unclear. Here we review the available literature on MPH dose optimization from clinical trials and real-world experience on ADHD management. In addition, we report safety and efficacy data from the largest MPH modified-release long-acting Phase III clinical trial conducted to examine benefits of dose optimization in adults with ADHD. Overall, MPH is an effective ADHD treatment with a good safety profile; data suggest that dose optimization may enhance the safety and efficacy of treatment. Further research is required to establish the extent to which short-term clinical benefits of MPH dose optimization translate into improved long-term outcomes for patients with ADHD. PMID:28740389

  15. Methylphenidate dose optimization for ADHD treatment: review of safety, efficacy, and clinical necessity.

    PubMed

    Huss, Michael; Duhan, Praveen; Gandhi, Preetam; Chen, Chien-Wei; Spannhuth, Carsten; Kumar, Vinod

    2017-01-01

    Attention-deficit/hyperactivity disorder (ADHD) is a chronic psychiatric disorder characterized by hyperactivity and/or inattention and is often associated with a substantial impact on psychosocial functioning. Methylphenidate (MPH), a central nervous system stimulant, is commonly used for pharmacological treatment of adults and children with ADHD. Current practice guidelines recommend optimizing MPH dosage to individual patient needs; however, the clinical benefits of individual dose optimization compared with fixed-dose regimens remain unclear. Here we review the available literature on MPH dose optimization from clinical trials and real-world experience on ADHD management. In addition, we report safety and efficacy data from the largest MPH modified-release long-acting Phase III clinical trial conducted to examine benefits of dose optimization in adults with ADHD. Overall, MPH is an effective ADHD treatment with a good safety profile; data suggest that dose optimization may enhance the safety and efficacy of treatment. Further research is required to establish the extent to which short-term clinical benefits of MPH dose optimization translate into improved long-term outcomes for patients with ADHD.

  16. MO-DE-204-01: Radiation Doses in Over 50 Developing Countries of Asia, Africa, Eastern European and Latin America

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rehani, M.

    2016-06-15

    The main topic of the session is to show how dose optimization is being implemented in various regions of the world, including Europe, Australia, North America and other regions. A multi-national study conducted under International Atomic Energy Agency (IAEA) across more than 50 less resourced countries gave insight into patient radiation doses and safety practices in CT, mammography, radiography and interventional procedures, both for children and adults. An important outcome was the capability development on dose assessment and management. An overview of recent European projects related to CT radiation dose and optimization both to adults and children will be presented.more » Existing data on DRLs together with a European methodology proposed on establishing and using DRLs for paediatric radiodiagnostic imaging and interventional radiology practices will be shown. Compared with much of Europe at least, many Australian imaging practices are relatively new to the task of diagnostic imaging dose optimisation. In 2008 the Australian Government prescribed a requirement to periodically compare patient radiation doses with diagnostic reference levels (DRLs), where DRLs have been established. Until recently, Australia had only established DRLs for computed tomography (CT). Regardless, both professional society and individual efforts to improved data collection and develop optimisation strategies across a range of modalities continues. Progress in this field, principally with respect to CT and interventional fluoroscopy will be presented. In the US, dose reduction and optimization efforts for computed tomography have been promoted and mandated by several organizations and accrediting entities. This presentation will cover the general motivation, implementation, and implications of such efforts. Learning Objectives: Understand importance of the dose optimization in Diagnostic Radiology. See how this goal is achieved in different regions of the World. Learn about the

  17. Neutrons in active proton therapy: Parameterization of dose and dose equivalent.

    PubMed

    Schneider, Uwe; Hälg, Roger A; Lomax, Tony

    2017-06-01

    One of the essential elements of an epidemiological study to decide if proton therapy may be associated with increased or decreased subsequent malignancies compared to photon therapy is an ability to estimate all doses to non-target tissues, including neutron dose. This work therefore aims to predict for patients using proton pencil beam scanning the spatially localized neutron doses and dose equivalents. The proton pencil beam of Gantry 1 at the Paul Scherrer Institute (PSI) was Monte Carlo simulated using GEANT. Based on the simulated neutron dose and neutron spectra an analytical mechanistic dose model was developed. The pencil beam algorithm used for treatment planning at PSI has been extended using the developed model in order to calculate the neutron component of the delivered dose distribution for each treated patient. The neutron dose was estimated for two patient example cases. The analytical neutron dose model represents the three-dimensional Monte Carlo simulated dose distribution up to 85cm from the proton pencil beam with a satisfying precision. The root mean square error between Monte Carlo simulation and model is largest for 138MeV protons and is 19% and 20% for dose and dose equivalent, respectively. The model was successfully integrated into the PSI treatment planning system. In average the neutron dose is increased by 10% or 65% when using 160MeV or 177MeV instead of 138MeV. For the neutron dose equivalent the increase is 8% and 57%. The presented neutron dose calculations allow for estimates of dose that can be used in subsequent epidemiological studies or, should the need arise, to estimate the neutron dose at any point where a subsequent secondary tumour may occur. It was found that the neutron dose to the patient is heavily increased with proton energy. Copyright © 2016. Published by Elsevier GmbH.

  18. Occupational dose constraints for the lens of the eye for interventional radiologists and interventional cardiologists in the UK.

    PubMed

    Mairs, William DA

    2016-06-01

    The International Commission on Radiological Protection (ICRP) has recommended a 20 mSv year(-1) dose limit for the lens of the eye, which has been adopted in the European Union Basic Safety Standards. Interventional radiologists (IRs) and interventional cardiologists (ICs) are likely to be affected by this. The effects of radiation in the lens are somewhat uncertain, and the ICRP explicitly recommend optimization. Occupational dose constraints are part of the optimization process and define a level of dose which ought to be achievable in a well-managed practice. This commentary calls on the professional bodies to review a need for national constraints to guide local decisions. Consideration is given to developing such constraints using maximum expected doses in high-workload facilities with good radiation protection practices and application of a factor allowing for attenuation by lead glasses (LG). Doses are based on a Public Health England survey of eye dose in the UK. Maximum expected doses for ICs are approximately 21 mSv year(-1), neglecting LG. However, the extent of IR exposure is not yet fully known, and further evidence is required before conclusions are drawn. A Health and Safety Laboratory review of LG established a conservative dose reduction factor of 3 for models available in 2012. Application of this factor provides a dose constraint of 7 mSv year(-1) to the eye for ICs. To achieve this constraint, those employers with the most exposed ICs will have to provide and ensure the correct use of a ceiling-suspended eye shield and LG.

  19. Benefits of adopting good radiation practices in reducing the whole body radiation dose to the nuclear medicine personnel during (18)F-fluorodeoxyglucose positron emission tomography/computed tomography imaging.

    PubMed

    Verma, Shashwat; Kheruka, Subhash Chand; Maurya, Anil Kumar; Kumar, Narvesh; Gambhir, Sanjay; Kumari, Sarita

    2016-01-01

    Positron emission tomography has been established as an important imaging modality in the management of patients, especially in oncology. The higher gamma radiation energy of positron-emitting isotopes poses an additional radiation safety problem. Those working with this modality may likely to receive higher whole body doses than those working only in conventional nuclear medicine. The radiation exposure to the personnel occurs in dispensing the dose, administration of activity, patient positioning, and while removing the intravenous (i.v.) cannula. The estimation of radiation dose to Nuclear Medicine Physician (NMP) involved during administration of activity to the patient and technical staff assisting in these procedures in a positron emission tomography/computed tomography (PET/CT) facility was carried out. An i.v access was secured for the patient by putting the cannula and blood sugar was monitored. The activity was then dispensed and measured in the dose calibrator and administered to the patient by NMP. Personnel doses received by NMP and technical staff were measured using electronic pocket dosimeter. The radiation exposure levels at various working locations were assessed with the help of gamma survey meter. The radiation level at working distance while administering the radioactivity was found to be 106-170 μSv/h with a mean value of 126.5 ± 14.88 μSv/h which was reduced to 4.2-14.2 μSv/h with a mean value of 7.16 ± 2.29 μSv/h with introduction of L-bench for administration of radioactivity. This shows a mean exposure level reduction of 94.45 ± 1.03%. The radiation level at working distance, while removing the i.v. cannula postscanning was found to be 25-70 μSv/h with a mean value of 37.4 ± 13.16 μSv/h which was reduced to 1.0-5.0 μSv/h with a mean value of 2.77 ± 1.3 μSv/h with introduction of L-bench for removal of i.v cannula. This shows a mean exposure level reduction of 92.85 ± 1.78%. This study shows that good radiation practices are

  20. Manual of Protective Action Guides and Protective Actions for Nuclear Incidents. Revision

    DTIC Science & Technology

    1980-06-01

    acceptable dose. Simce the PAC In based on a projected does, It is used only In an expost facto effort to minmisea the risk from an swest which is occurring...statistical evaluation of epidmiological studies In groups of people wbo had been ezposed to radiation. Decisions concerning statistical effects on...protective actions. The Reactor Saety Study Indicates, for ezample, that major releases y beoon in the range of one-half how to as uab as 30 hours after an

  1. Dose Titration Algorithm Tuning (DTAT) should supersede 'the' Maximum Tolerated Dose (MTD) in oncology dose-finding trials.

    PubMed

    Norris, David C

    2017-01-01

    Background . Absent adaptive, individualized dose-finding in early-phase oncology trials, subsequent 'confirmatory' Phase III trials risk suboptimal dosing, with resulting loss of statistical power and reduced probability of technical success for the investigational therapy. While progress has been made toward explicitly adaptive dose-finding and quantitative modeling of dose-response relationships, most such work continues to be organized around a concept of 'the' maximum tolerated dose (MTD). The purpose of this paper is to demonstrate concretely how the aim of early-phase trials might be conceived, not as 'dose-finding', but as dose titration algorithm (DTA) -finding. Methods. A Phase I dosing study is simulated, for a notional cytotoxic chemotherapy drug, with neutropenia constituting the critical dose-limiting toxicity. The drug's population pharmacokinetics and myelosuppression dynamics are simulated using published parameter estimates for docetaxel. The amenability of this model to linearization is explored empirically. The properties of a simple DTA targeting neutrophil nadir of 500 cells/mm 3 using a Newton-Raphson heuristic are explored through simulation in 25 simulated study subjects. Results. Individual-level myelosuppression dynamics in the simulation model approximately linearize under simple transformations of neutrophil concentration and drug dose. The simulated dose titration exhibits largely satisfactory convergence, with great variance in individualized optimal dosing. Some titration courses exhibit overshooting. Conclusions. The large inter-individual variability in simulated optimal dosing underscores the need to replace 'the' MTD with an individualized concept of MTD i . To illustrate this principle, the simplest possible DTA capable of realizing such a concept is demonstrated. Qualitative phenomena observed in this demonstration support discussion of the notion of tuning such algorithms. Although here illustrated specifically in relation to

  2. Placebo-controlled pilot trial testing dose titration and intravenous, intramuscular and subcutaneous routes for ketamine in depression.

    PubMed

    Loo, C K; Gálvez, V; O'Keefe, E; Mitchell, P B; Hadzi-Pavlovic, D; Leyden, J; Harper, S; Somogyi, A A; Lai, R; Weickert, C S; Glue, P

    2016-07-01

    This pilot study assessed the feasibility, efficacy and safety of an individual dose-titration approach, and of the intravenous (IV), intramuscular (IM) and subcutaneous (SC) routes for treating depression with ketamine. Fifteen treatment-refractory depressed participants received ketamine or midazolam (control treatment) in a multiple crossover, double-blind study. Ketamine was administered by IV (n = 4), IM (n = 5) or SC (n = 6) injection. Dose titration commenced at 0.1 mg/kg, increasing by 0.1 mg/kg up to 0.5 mg/kg, given in separate treatment sessions separated by ≥1 week, with one placebo control treatment randomly inserted. Mood, psychotomimetic and hemodynamic effects were assessed and plasma ketamine concentrations assayed. Twelve participants achieved response and remission criteria, achieved at doses as low as 0.1 mg/kg. All three routes of administration resulted in comparable antidepressant effects. Fewest adverse effects were noted with the SC route. Antidepressant response, adverse effects and ketamine concentrations were dose-related. Antidepressant response occurred at a range of doses and at <0.5 mg/kg. The dose-titration approach is a practical method for optimizing the efficacy - side-effects trade-off on an individual patient basis. This pilot study provides preliminary evidence for SC injection as a practical, feasible and efficacious treatment approach. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. Symptom relief in patients with pneumonia and dementia: implementation of a practice guideline.

    PubMed

    van der Maaden, Tessa; van der Steen, Jenny T; Koopmans, Raymond T C M; Doncker, Sarah M M M; Anema, Johannes R; Hertogh, Cees M P M; de Vet, Henrica C W

    2017-08-01

    This study aimed to assess the degree of implementation and barriers encountered in the use of a practice guideline for optimal symptom relief for patients with dementia and pneumonia in Dutch nursing homes. A process evaluation included assessment of reach, fidelity, and dose delivered using researcher's observations, and dose received was addressed in a question "use of the practice guideline," which the physicians completed for each patient included in the study. Perceived barriers were assessed with a structured questionnaire (response 69%) and semi-structured interviews (n = 14), which were subject to qualitative content analysis. Of the 55 physicians involved in the intervention phase, 87% attended an implementation meeting; 20 physicians joined the study later (reach). The intervention was implemented as planned, and all intervention components were delivered by the researchers (fidelity and dose delivered). Thirty-six physicians included 109 patients. For 81% of the patients, the treating physician stated to have used the guideline (dose received). The guideline was perceived as providing a good overview of current practice, but some physicians had expected a more directive protocol or algorithm. Further, recommended regular observations of symptoms were rarely performed. Physician's often felt that "this is not different from what we usually do," and with the acute illness, there was not always enough time to (re)familiarize with the contents. The physicians used the practice guideline frequently despite important barriers. Future implementation may involve strategies such as multiple interactive meetings. Further, the greatest potential to alter usual practice should be emphasized, such as using observational instruments. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  4. Appropriate Use of Effective Dose in Radiation Protection and Risk Assessment.

    PubMed

    Fisher, Darrell R; Fahey, Frederic H

    2017-08-01

    Effective dose was introduced by the ICRP for the single, over-arching purpose of setting limits for radiation protection. Effective dose is a derived quantity or mathematical construct and not a physical, measurable quantity. The formula for calculating effective dose to a reference model incorporates terms to account for all radiation types, organ and tissue radiosensitivities, population groups, and multiple biological endpoints. The properties and appropriate applications of effective dose are not well understood by many within and outside the health physics profession; no other quantity in radiation protection has been more confusing or misunderstood. According to ICRP Publication 103, effective dose is to be used for "prospective dose assessment for planning and optimization in radiological protection, and retrospective demonstration of compliance for regulatory purposes." In practice, effective dose has been applied incorrectly to predict cancer risk among exposed persons. The concept of effective dose applies generally to reference models only and not to individual subjects. While conceived to represent a measure of cancer risk or heritable detrimental effects, effective dose is not predictive of future cancer risk. The formula for calculating effective dose incorporates committee-selected weighting factors for radiation quality and organ sensitivity; however, the organ weighting factors are averaged across all ages and both genders and thus do not apply to any specific individual or radiosensitive subpopulations such as children and young women. Further, it is not appropriate to apply effective dose to individual medical patients because patient-specific parameters may vary substantially from the assumptions used in generalized models. Also, effective dose is not applicable to therapeutic uses of radiation, as its mathematical underpinnings pertain only to observed late (stochastic) effects of radiation exposure and do not account for short-term adverse

  5. Technical note: estimating absorbed doses to the thyroid in CT.

    PubMed

    Huda, Walter; Magill, Dennise; Spampinato, Maria V

    2011-06-01

    To describe a method for estimating absorbed doses to the thyroid in patients undergoing neck CT examinations. Thyroid doses in anthropomorphic phantoms were obtained for all 23 scanner dosimetry data sets in the ImPACT CT patient dosimetry calculator. Values of relative thyroid dose [R(thy)(L)], defined as the thyroid dose for a given scan length (L) divided by the corresponding thyroid dose for a whole body scan, were determined for neck CT scans. Ratios of the maximum thyroid dose to the corresponding CTDI(vol) and [D'(thy)], were obtained for two phantom diameters. The mass-equivalent water cylinder of any patient can be derived from the neck cross-sectional area and the corresponding average Hounsfield Unit, and compared to the 16.5-cm diameter water cylinder that models the ImPACT anthropomorphic phantom neck. Published values of relative doses in water cylinders of varying diameter were used to adjust thyroid doses in the anthropomorphic phantom to those of any sized patient. Relative thyroid doses R(thy)(L) increase to unity with increasing scan length and with very small difference between scanners. A 10-cm scan centered on the thyroid would result in a dose that is, nearly 90% of the thyroid dose from a whole body scan when performed using the constant radiographic techniques. At 120 kV, the average value of D'(thy) for the 16-cm diameter was 1.17 +/- 0.05 and was independent of CT vendor and year of CT scanner, and choice of x-ray tube voltage. The corresponding average value of D'(thy) in the 32-cm diameter phantom was 2.28 +/- 0.22 and showed marked variations depending on vendor, year of introduction into clinical practice as well as x-ray tube voltage. At 120 kV, a neck equivalent to a 10-cm diameter cylinder of water would have thyroid doses 36% higher than those in the ImPACT phantom, whereas a neck equivalent to a 25-cm cylinder diameter would have thyroid doses 35% lower. Patient thyroid doses can be estimated by taking into account the amount of

  6. Dose reduction of up to 89% while maintaining image quality in cardiovascular CT achieved with prospective ECG gating

    NASA Astrophysics Data System (ADS)

    Londt, John H.; Shreter, Uri; Vass, Melissa; Hsieh, Jiang; Ge, Zhanyu; Adda, Olivier; Dowe, David A.; Sabllayrolles, Jean-Louis

    2007-03-01

    We present the results of dose and image quality performance evaluation of a novel, prospective ECG-gated Coronary CT Angiography acquisition mode (SnapShot Pulse, LightSpeed VCT-XT scanner, GE Healthcare, Waukesha, WI), and compare it to conventional retrospective ECG gated helical acquisition in clinical and phantom studies. Image quality phantoms were used to measure noise, slice sensitivity profile, in-plane resolution, low contrast detectability and dose, using the two acquisition modes. Clinical image quality and diagnostic confidence were evaluated in a study of 31 patients scanned with the two acquisition modes. Radiation dose reduction in clinical practice was evaluated by tracking 120 consecutive patients scanned with the prospectively gated scan mode. In the phantom measurements, the prospectively gated mode resulted in equivalent or better image quality measures at dose reductions of up to 89% compared to non-ECG modulated conventional helical scans. In the clinical study, image quality was rated excellent by expert radiologist reviewing the cases, with pathology being identical using the two acquisition modes. The average dose to patients in the clinical practice study was 5.6 mSv, representing 50% reduction compared to a similar patient population scanned with the conventional helical mode.

  7. TH-E-209-03: Development of An In-House CT Dose Monitoring and Management System Based On Open-Source Software Resources -- Pearls and Pitfalls

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, D.

    Radiation dose monitoring solutions have opened up new opportunities for medical physicists to be more involved in modern clinical radiology practices. In particular, with the help of comprehensive radiation dose data, data-driven protocol management and informed case follow up are now feasible. Significant challenges remain however and the problems faced by medical physicists are highly heterogeneous. Imaging systems from multiple vendors and a wide range of vintages co-exist in the same department and employ data communication protocols that are not fully standardized or implemented making harmonization complex. Many different solutions for radiation dose monitoring have been implemented by imaging facilitiesmore » over the past few years. Such systems are based on commercial software, home-grown IT solutions, manual PACS data dumping, etc., and diverse pathways can be used to bring the data to impact clinical practice. The speakers will share their experiences with creating or tailoring radiation dose monitoring/management systems and procedures over the past few years, which vary significantly in design and scope. Topics to cover: (1) fluoroscopic dose monitoring and high radiation event handling from a large academic hospital; (2) dose monitoring and protocol optimization in pediatric radiology; and (3) development of a home-grown IT solution and dose data analysis framework. Learning Objectives: Describe the scope and range of radiation dose monitoring and protocol management in a modern radiology practice Review examples of data available from a variety of systems and how it managed and conveyed. Reflect on the role of the physicist in radiation dose awareness.« less

  8. Low dose scatter correction for digital chest tomosynthesis

    NASA Astrophysics Data System (ADS)

    Inscoe, Christina R.; Wu, Gongting; Shan, Jing; Lee, Yueh Z.; Zhou, Otto; Lu, Jianping

    2015-03-01

    Digital chest tomosynthesis (DCT) provides superior image quality and depth information for thoracic imaging at relatively low dose, though the presence of strong photon scatter degrades the image quality. In most chest radiography, anti-scatter grids are used. However, the grid also blocks a large fraction of the primary beam photons requiring a significantly higher imaging dose for patients. Previously, we have proposed an efficient low dose scatter correction technique using a primary beam sampling apparatus. We implemented the technique in stationary digital breast tomosynthesis, and found the method to be efficient in correcting patient-specific scatter with only 3% increase in dose. In this paper we reported the feasibility study of applying the same technique to chest tomosynthesis. This investigation was performed utilizing phantom and cadaver subjects. The method involves an initial tomosynthesis scan of the object. A lead plate with an array of holes, or primary sampling apparatus (PSA), was placed above the object. A second tomosynthesis scan was performed to measure the primary (scatter-free) transmission. This PSA data was used with the full-field projections to compute the scatter, which was then interpolated to full-field scatter maps unique to each projection angle. Full-field projection images were scatter corrected prior to reconstruction. Projections and reconstruction slices were evaluated and the correction method was found to be effective at improving image quality and practical for clinical implementation.

  9. Collagenous colitis: Requirement for high-dose budesonide as maintenance treatment.

    PubMed

    Fernandez-Bañares, Fernando; Piqueras, Marta; Guagnozzi, Danila; Robles, Virginia; Ruiz-Cerulla, Alexandra; Casanova, María José; Gisbert, Javier P; Busquets, David; Arguedas, Yolanda; Pérez-Aisa, Angeles; Fernández-Salazar, Luis; Lucendo, Alfredo J

    2017-09-01

    Controlled studies show high efficacy of budesonide in inducing short-term clinical remission in collagenous colitis (CC), but relapses are common after its withdrawal. To evaluate the need for high-dose budesonide (≥6mg/d) to maintain clinical remission in CC. Analysis of a multicentre retrospective cohort of 75 patients with CC (62.3±1.5years; 85% women) treated with budesonide in a clinical practice setting between 2013 and 2015. Frequency of budesonide (9mg/d) refractoriness and safety, and the need for high-dose budesonide to maintain clinical remission, were evaluated. Drugs used as budesonide-sparing, including azathioprine and mercaptopurine, were recorded. Logistic regression analysis was performed to evaluate the risk factors associated with the need for high-dose budesonide (≥6mg/d) to maintain clinical remission. Budesonide induced clinical remission in 92% of patients, with good tolerance. Fourteen of 68 patients (21%; 95% CI, 13-32%) needed high-dose budesonide to maintain remission. Only intake of NSAIDs at diagnosis (OR, 8.6; 95% CI, 1.6-44) was associated with the need for high-dose budesonide in the multivariate analysis. with thiopurines was effective in 5 out of 6 patients (83%; 95% CI, 44-97%), allowing for withdrawal from or a dose decrease of budesonide. One fifth of CC patients, especially those with NSAID intake at diagnosis, require high-dose budesonide (≥6mg/d) to maintain clinical remission. In this setting, thiopurines might be effective as budesonide-sparing drugs. Copyright © 2017 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  10. Dose assessment of 2% chlorhexidine acetate for canine superficial pyoderma.

    PubMed

    Murayama, Nobuo; Terada, Yuri; Okuaki, Mio; Nagata, Masahiko

    2011-10-01

    The dose of 2% chlorhexidine acetate (2CA; Nolvasan(®) Surgical Scrub; Fort Dodge Animal Health, Fort Dodge, IA, USA) for canine superficial pyoderma was evaluated. The first trial compared three doses (group 1, 57 mL/m(2) body surface area; group 2, 29 mL/m(2) body surface area; and group 3, 19 mL/m(2) body surface area) in a randomized, double-blind, controlled fashion. Twenty-seven dogs with superficial pyoderma were treated with 2CA at the allocated doses every 2 days for 1 week. The owners and investigators subjectively evaluated the dogs, and investigators scored skin lesions, including erythema, papules/pustules, alopecia and scales, on a 0-4 scale. There were no significant differences in response between the treatment groups. The second trial established a practical dose-measuring method for 2CA. Sixty-eight owners were asked to apply 2CA on their palm in an amount corresponding to a Japanese ¥500 coin, 26.5 mm in diameter. This yielded an average dose of 0.90±0.40 mL. Mathematically, the doses used in groups 1, 2 and 3 can be represented as one coin per approximately one-, two- and three-hand-sized lesions, respectively. The results therefore suggest that owners instructed to apply one coin of the product per two-hand-sized areas of superficial pyoderma would use the range of doses evaluated in this trial. © 2011 The Authors. Veterinary Dermatology. © 2011 ESVD and ACVD.

  11. A dose error evaluation study for 4D dose calculations

    NASA Astrophysics Data System (ADS)

    Milz, Stefan; Wilkens, Jan J.; Ullrich, Wolfgang

    2014-10-01

    Previous studies have shown that respiration induced motion is not negligible for Stereotactic Body Radiation Therapy. The intrafractional breathing induced motion influences the delivered dose distribution on the underlying patient geometry such as the lung or the abdomen. If a static geometry is used, a planning process for these indications does not represent the entire dynamic process. The quality of a full 4D dose calculation approach depends on the dose coordinate transformation process between deformable geometries. This article provides an evaluation study that introduces an advanced method to verify the quality of numerical dose transformation generated by four different algorithms. The used transformation metric value is based on the deviation of the dose mass histogram (DMH) and the mean dose throughout dose transformation. The study compares the results of four algorithms. In general, two elementary approaches are used: dose mapping and energy transformation. Dose interpolation (DIM) and an advanced concept, so called divergent dose mapping model (dDMM), are used for dose mapping. The algorithms are compared to the basic energy transformation model (bETM) and the energy mass congruent mapping (EMCM). For evaluation 900 small sample regions of interest (ROI) are generated inside an exemplary lung geometry (4DCT). A homogeneous fluence distribution is assumed for dose calculation inside the ROIs. The dose transformations are performed with the four different algorithms. The study investigates the DMH-metric and the mean dose metric for different scenarios (voxel sizes: 8 mm, 4 mm, 2 mm, 1 mm 9 different breathing phases). dDMM achieves the best transformation accuracy in all measured test cases with 3-5% lower errors than the other models. The results of dDMM are reasonable and most efficient in this study, although the model is simple and easy to implement. The EMCM model also achieved suitable results, but the approach requires a more complex

  12. A dose error evaluation study for 4D dose calculations.

    PubMed

    Milz, Stefan; Wilkens, Jan J; Ullrich, Wolfgang

    2014-11-07

    Previous studies have shown that respiration induced motion is not negligible for Stereotactic Body Radiation Therapy. The intrafractional breathing induced motion influences the delivered dose distribution on the underlying patient geometry such as the lung or the abdomen. If a static geometry is used, a planning process for these indications does not represent the entire dynamic process. The quality of a full 4D dose calculation approach depends on the dose coordinate transformation process between deformable geometries. This article provides an evaluation study that introduces an advanced method to verify the quality of numerical dose transformation generated by four different algorithms.The used transformation metric value is based on the deviation of the dose mass histogram (DMH) and the mean dose throughout dose transformation. The study compares the results of four algorithms. In general, two elementary approaches are used: dose mapping and energy transformation. Dose interpolation (DIM) and an advanced concept, so called divergent dose mapping model (dDMM), are used for dose mapping. The algorithms are compared to the basic energy transformation model (bETM) and the energy mass congruent mapping (EMCM). For evaluation 900 small sample regions of interest (ROI) are generated inside an exemplary lung geometry (4DCT). A homogeneous fluence distribution is assumed for dose calculation inside the ROIs. The dose transformations are performed with the four different algorithms.The study investigates the DMH-metric and the mean dose metric for different scenarios (voxel sizes: 8 mm, 4 mm, 2 mm, 1 mm; 9 different breathing phases). dDMM achieves the best transformation accuracy in all measured test cases with 3-5% lower errors than the other models. The results of dDMM are reasonable and most efficient in this study, although the model is simple and easy to implement. The EMCM model also achieved suitable results, but the approach requires a more complex programming

  13. Non-linear relationship of cell hit and transformation probabilities in a low dose of inhaled radon progenies.

    PubMed

    Balásházy, Imre; Farkas, Arpád; Madas, Balázs Gergely; Hofmann, Werner

    2009-06-01

    Cellular hit probabilities of alpha particles emitted by inhaled radon progenies in sensitive bronchial epithelial cell nuclei were simulated at low exposure levels to obtain useful data for the rejection or support of the linear-non-threshold (LNT) hypothesis. In this study, local distributions of deposited inhaled radon progenies in airway bifurcation models were computed at exposure conditions characteristic of homes and uranium mines. Then, maximum local deposition enhancement factors at bronchial airway bifurcations, expressed as the ratio of local to average deposition densities, were determined to characterise the inhomogeneity of deposition and to elucidate their effect on resulting hit probabilities. The results obtained suggest that in the vicinity of the carinal regions of the central airways the probability of multiple hits can be quite high, even at low average doses. Assuming a uniform distribution of activity there are practically no multiple hits and the hit probability as a function of dose exhibits a linear shape in the low dose range. The results are quite the opposite in the case of hot spots revealed by realistic deposition calculations, where practically all cells receive multiple hits and the hit probability as a function of dose is non-linear in the average dose range of 10-100 mGy.

  14. Superficial dose evaluation of four dose calculation algorithms

    NASA Astrophysics Data System (ADS)

    Cao, Ying; Yang, Xiaoyu; Yang, Zhen; Qiu, Xiaoping; Lv, Zhiping; Lei, Mingjun; Liu, Gui; Zhang, Zijian; Hu, Yongmei

    2017-08-01

    Accurate superficial dose calculation is of major importance because of the skin toxicity in radiotherapy, especially within the initial 2 mm depth being considered more clinically relevant. The aim of this study is to evaluate superficial dose calculation accuracy of four commonly used algorithms in commercially available treatment planning systems (TPS) by Monte Carlo (MC) simulation and film measurements. The superficial dose in a simple geometrical phantom with size of 30 cm×30 cm×30 cm was calculated by PBC (Pencil Beam Convolution), AAA (Analytical Anisotropic Algorithm), AXB (Acuros XB) in Eclipse system and CCC (Collapsed Cone Convolution) in Raystation system under the conditions of source to surface distance (SSD) of 100 cm and field size (FS) of 10×10 cm2. EGSnrc (BEAMnrc/DOSXYZnrc) program was performed to simulate the central axis dose distribution of Varian Trilogy accelerator, combined with measurements of superficial dose distribution by an extrapolation method of multilayer radiochromic films, to estimate the dose calculation accuracy of four algorithms in the superficial region which was recommended in detail by the ICRU (International Commission on Radiation Units and Measurement) and the ICRP (International Commission on Radiological Protection). In superficial region, good agreement was achieved between MC simulation and film extrapolation method, with the mean differences less than 1%, 2% and 5% for 0°, 30° and 60°, respectively. The relative skin dose errors were 0.84%, 1.88% and 3.90%; the mean dose discrepancies (0°, 30° and 60°) between each of four algorithms and MC simulation were (2.41±1.55%, 3.11±2.40%, and 1.53±1.05%), (3.09±3.00%, 3.10±3.01%, and 3.77±3.59%), (3.16±1.50%, 8.70±2.84%, and 18.20±4.10%) and (14.45±4.66%, 10.74±4.54%, and 3.34±3.26%) for AXB, CCC, AAA and PBC respectively. Monte Carlo simulation verified the feasibility of the superficial dose measurements by multilayer Gafchromic films. And the rank

  15. Enhanced Low Dose Rate Sensitivity at Ultra-Low Dose Rates

    NASA Technical Reports Server (NTRS)

    Chen, Dakai; Pease, Ronald; Forney, James; Carts, Martin; Phan, Anthony; Cox, Stephen; Kruckmeyer, Kriby; Burns, Sam; Albarian, Rafi; Holcombe, Bruce; hide

    2011-01-01

    We have presented results of ultra-low dose rate irradiations (< or = 10 mrad(Si)/s) for a variety of radiation hardened and commercial linear bipolar devices. We observed low dose rate enhancement factors exceeding 1.5 in several parts. The worst case of dose rate enhancement resulted in functional failures, which occurred after 10 and 60 krad(Si), for devices irradiated at 0.5 and 10 mrad(Si)/s, respectively. Devices fabricated with radiation hardened processes and designs also displayed dose rate enhancement at below 10 mrad(Si)/s. Furthermore, the data indicated that these devices have not reached the damage saturation point. Therefore the degradation will likely continue to increase with increasing total dose, and the low dose rate enhancement will further magnify. The cases presented here, in addition to previous examples, illustrate the significance and pervasiveness of low dose rate enhancement at dose rates lower than 10 mrad(Si). These results present further challenges for radiation hardness assurance of bipolar linear circuits, and raise the question of whether the current standard test dose rate is conservative enough to bound degradations due to ELDRS.

  16. Effects of Epoetin Alfa Titration Practices, Implemented After Changes to Product Labeling, on Hemoglobin Levels, Transfusion Use, and Hospitalization Rates.

    PubMed

    Molony, Julia T; Monda, Keri L; Li, Suying; Beaubrun, Anne C; Gilbertson, David T; Bradbury, Brian D; Collins, Allan J

    2016-08-01

    Little is known about epoetin alfa (EPO) dosing at dialysis centers after implementation of the US Medicare prospective payment system and revision of the EPO label in 2011. Retrospective cohort study. Approximately 412,000 adult hemodialysis patients with Medicare Parts A and B as primary payer in 2009 to 2012 to describe EPO dosing and hemoglobin patterns; of these, about 70,000 patients clustered in about 1,300 dialysis facilities to evaluate facility-level EPO titration practices and patient-level outcomes in 2012. Facility EPO titration practices when hemoglobin levels were <10 and >11g/dL (grouped treatment variable) determined from monthly EPO dosing and hemoglobin level patterns. Patient mean hemoglobin levels, red blood cell transfusion rates, and all-cause and cause-specific hospitalization rates using a facility-based analysis. Monthly EPO dose and hemoglobin level, red blood cell transfusion rates, and all-cause and cause-specific hospitalization rates. Monthly EPO doses declined across all hemoglobin levels, with the greatest decline in patients with hemoglobin levels < 10g/dL (July-October 2011). In 2012, nine distinct facility titration practices were identified. Across groups, mean hemoglobin levels differed slightly (10.5-10.8g/dL) but within-patient hemoglobin standard deviations were similar (∼0.68g/dL). Patients at facilities implementing greater dose reductions and smaller dose escalations had lower hemoglobin levels and higher transfusion rates. In contrast, patients at facilities that implemented greater dose escalations (and large or small dose reductions) had higher hemoglobin levels and lower transfusion rates. There were no clinically meaningful differences in all-cause or cause-specific hospitalization events across groups. Possibly incomplete claims data; excluded small facilities and those without consistent titration patterns; hemoglobin levels reported monthly; inferred facility practice from observed dosing. Following

  17. Distinguishing dose, focus, and blur for lithography characterization and control

    NASA Astrophysics Data System (ADS)

    Ausschnitt, Christopher P.; Brunner, Timothy A.

    2007-03-01

    We derive a physical model to describe the dependence of pattern dimensions on dose, defocus and blur. The coefficients of our model are constants of a given lithographic process. Model inversion applied to dimensional measurements then determines effective dose, defocus and blur for wafers patterned with the same process. In practice, our approach entails the measurement of proximate grating targets of differing dose and focus sensitivity. In our embodiment, the measured attribute of one target is exclusively sensitive to dose, whereas the measured attributes of a second target are distinctly sensitive to defocus and blur. On step-and-scan exposure tools, z-blur is varied in a controlled manner by adjusting the across slit tilt of the image plane. The effects of z-blur and x,y-blur are shown to be equivalent. Furthermore, the exposure slit width is shown to determine the tilt response of the grating attributes. Thus, the response of the measured attributes can be characterized by a conventional focus-exposure matrix (FEM), over which the exposure tool settings are intentionally changed. The model coefficients are determined by a fit to the measured FEM response. The model then fully defines the response for wafers processed under "fixed" dose, focus and blur conditions. Model inversion applied to measurements from the same targets on all such wafers enables the simultaneous determination of effective dose and focus/tilt (DaFT) at each measurement site.

  18. GENERAL CONSIDERATIONS OF DOSE-EFFECT AND DOSE-RESPONSE RELATIONSHIPS

    EPA Science Inventory

    ABSTRACT In 2003, the International Union of Pure and Applied chemistry (IUPAC) issued a glossary of terms that included the defi nition of dose-effect and doseresponse relationships (Nordberg et al., 2004). Dose effect relationship is defined as an association between dose and...

  19. [Could it be a little less? Let the dose of thiopental in euthanasia depend on the body weight].

    PubMed

    Sprij, Bram

    2010-01-01

    The Dutch 'euthanasia and assisted suicide' practice guideline advises using 2000 mg thiopental to induce coma, followed by a muscle relaxant to cause death by respiratory paralysis. However, when a doctor administers such a high dose of thiopental as a bolus injection to a cachectic patient, there is a high likelihood of immediate death and other side effects, which can be distressing for the family. Doctors who administered less than 2000 mg have been reprimanded for not working according to current standards. Arguments are given concerning in which circumstances it is reasonable to use the advised dose of 2000 mg of thiopental and when to use less thiopental to induce coma by direct intravenous injection. The author suggests that it may be better to adjust the dose of thiopental according to the body weight of the patient. The current practice guideline needs revision.

  20. Insights into implementation of sacubitril/valsartan into clinical practice

    PubMed Central

    Martens, Pieter; Beliën, Hanne; Dupont, Matthias

    2018-01-01

    Abstract Background Sacubitril/valsartan significantly reduced heart failure hospitalization and mortality in PARADIGM‐HF (Prospective Comparison of Angiotensin Receptor‐Neprilysin Inhibitor With an Angiotensin‐Converting Enzyme Inhibitor to Determine Impact on Global Mortality and Morbidity in Heart Failure). However, real‐world data from its use are lacking. Methods and results We retrospectively assessed all baseline and follow‐up data of consecutive heart failure patients with reduced ejection fraction receiving therapy with sacubitril/valsartan for Class I recommendation between December 2016 and July 2017. Baseline characteristics and dose titration of sacubitril/valsartan were compared between patients in clinical practice and in PARADIGM‐HF. A total of 120 patients (81% male) were switched from angiotensin‐converting enzyme inhibitor or angiotensin receptor blocker to sacubitril/valsartan. A total of 20.1% of patients received dose uptitration. Patients were treated with an equipotential dose of renin–angiotensin system blockers before and after uptitration of sacubitril/valsartan (57 ± 29% vs. 53 ± 29% of target dose indicated by European Society of Cardiology guidelines; P = 0.286). However, they received a lower dose of sacubitril/valsartan in comparison with those in the PARADIGM‐HF (219 ± 12 vs. 375 ± 75 mg; P < 0.001). In comparison with the patients receiving sacubitril/valsartan in PARADIGM‐HF, patients in clinical practice were older and had a higher serum creatinine, higher New York Heart Association functional classification, and lower left ventricular ejection fraction (all P‐value <0.05). Even in comparison with patients who experienced dropout during the run‐in phase of PARADIGM‐HF, real‐world patients exhibited baseline characteristics indicative of more disease severity. Patients were at high absolute baseline risk for adverse outcome as illustrated by the EMPHASIS‐HF (Eplerenone in Mild

  1. Opening the Gates to Foster Scholarship for Urban Students: Organizational Policies and Systemic Practices in a High Performing High Poverty Urban High School

    ERIC Educational Resources Information Center

    Ellis, Regina Anderson

    2012-01-01

    The problem of underachievement seems to exist in school districts across the country, particularly, where there are a significant percentage of students of color and low socio-economic groups. The purpose of this qualitative case study, conducted with an ex post facto approach, was to bring to light the organizational policies and systemic…

  2. Doses of olanzapine, risperidone, and haloperidol used in clinical practice: results of a prospective pharmacoepidemiologic study. EFESO Study Group. Estudio Farmacoepidemiologico en la Esquizofrenia con Olanzapina.

    PubMed

    Sacristán, J A; Gómez, J C; Montejo, A L; Vieta, E; Gregor, K J

    2000-05-01

    The objectives of this study were to determine the doses of olanzapine (OLZ), risperidone (RIS), and haloperidol (HAL) used in clinical practice in outpatients with schizophrenia and the rates of occurrence of extrapyramidal symptoms (EPS) and other adverse events, clinical response, and use of concomitant medications. The present study involved a subset of patients from a 6-month, open-label, prospective observational study. Data were collected by 293 psychiatrists at mental health centers and other outpatient treatment facilities in Spain. Medications and doses used, occurrence of EPS and other adverse events, and scores on the Clinical Global Impression (CGI) of Severity Scale and Global Assessment of Function (GAF) were recorded. Clinical response was defined as a decrease of > or = 2 points on the CGI, with a final CGI score < or = 4. A total of 2657 patients were included in the analysis. The initial and overall mean daily doses for the 3 groups were as follows: OLZ, 12.2 and 13.0 mg, respectively; RIS, 5.2 and 5.4 mg; and HAL, 13.9 and 13.6 mg. Initial and overall median daily doses were the same in each group: OLZ, 10 mg; RIS, 6 mg; and HAL, 10 mg. A significantly lower proportion of OLZ-treated patients (36.9%) experienced EPS compared with RIS-treated (49.6%) and HAL-treated (76.0%) patients (P < or = 0.001). A significantly lower proportion of patients in the OLZ group (47.8%) experienced adverse events compared with patients in the RIS (57.2%) and HAL (79.8%) groups (P < or = 0.001). A significantly greater proportion of OLZ-treated patients (37.3%) were responders compared with RIS-treated patients (31.5%) (P < 0.05). In all 3 groups, patients who had an initial CGI score > or = 5 received significantly higher overall mean daily doses than did patients with an initial CGI score < 5 (P < 0.001). A significantly lower proportion of OLZ-treated patients (10.2%) were receiving concomitant anticholinergic medication at the end of the study (month 6

  3. Dose-finding design for multi-drug combinations

    PubMed Central

    Wages, Nolan A; Conaway, Mark R; O'Quigley, John

    2012-01-01

    Background Most of the current designs used for Phase I dose finding trials in oncology will either involve only a single cytotoxic agent or will impose some implicit ordering among the doses. The goal of the studies is to estimate the maximum tolerated dose (MTD), the highest dose that can be administered with an acceptable level of toxicity. A key working assumption of these methods is the monotonicity of the dose–toxicity curve. Purpose Here we consider situations in which the monotonicity assumption may fail. These studies are becoming increasingly common in practice, most notably, in phase I trials that involve combinations of agents. Our focus is on studies where there exist pairs of treatment combinations for which the ordering of the probabilities of a dose-limiting toxicity cannot be known a priori. Methods We describe a new dose-finding design which can be used for multiple-drug trials and can be applied to this kind of problem. Our methods proceed by laying out all possible orderings of toxicity probabilities that are consistent with the known orderings among treatment combinations and allowing the continual reassessment method (CRM) to provide efficient estimates of the MTD within these orders. The design can be seen to simplify to the CRM when the full ordering is known. Results We study the properties of the design via simulations that provide comparisons to the Bayesian approach to partial orders (POCRM) of Wages, Conaway, and O'Quigley. The POCRM was shown to perform well when compared to other suggested methods for partial orders. Therefore, we comapre our approach to it in order to assess the performance of the new design. Limitations A limitation concerns the number of possible orders. There are dose-finding studies with combinations of agents that can lead to a large number of possible orders. In this case, it may not be feasible to work with all possible orders. Conclusions The proposed design demonstrates the ability to effectively estimate

  4. Dose Titration Algorithm Tuning (DTAT) should supersede ‘the’ Maximum Tolerated Dose (MTD) in oncology dose-finding trials

    PubMed Central

    Norris, David C.

    2017-01-01

    Background. Absent adaptive, individualized dose-finding in early-phase oncology trials, subsequent ‘confirmatory’ Phase III trials risk suboptimal dosing, with resulting loss of statistical power and reduced probability of technical success for the investigational therapy. While progress has been made toward explicitly adaptive dose-finding and quantitative modeling of dose-response relationships, most such work continues to be organized around a concept of ‘the’ maximum tolerated dose (MTD). The purpose of this paper is to demonstrate concretely how the aim of early-phase trials might be conceived, not as ‘dose-finding’, but as dose titration algorithm (DTA)-finding. Methods. A Phase I dosing study is simulated, for a notional cytotoxic chemotherapy drug, with neutropenia constituting the critical dose-limiting toxicity. The drug’s population pharmacokinetics and myelosuppression dynamics are simulated using published parameter estimates for docetaxel. The amenability of this model to linearization is explored empirically. The properties of a simple DTA targeting neutrophil nadir of 500 cells/mm 3 using a Newton-Raphson heuristic are explored through simulation in 25 simulated study subjects. Results. Individual-level myelosuppression dynamics in the simulation model approximately linearize under simple transformations of neutrophil concentration and drug dose. The simulated dose titration exhibits largely satisfactory convergence, with great variance in individualized optimal dosing. Some titration courses exhibit overshooting. Conclusions. The large inter-individual variability in simulated optimal dosing underscores the need to replace ‘the’ MTD with an individualized concept of MTD i . To illustrate this principle, the simplest possible DTA capable of realizing such a concept is demonstrated. Qualitative phenomena observed in this demonstration support discussion of the notion of tuning such algorithms. Although here illustrated specifically

  5. Preventing and Managing Toxicities of High-Dose Methotrexate

    PubMed Central

    McCormick, John; Pui, Ching-Hon; Buddington, Randall K.; Harvey, R. Donald

    2016-01-01

    High-dose methotrexate (HDMTX), defined as a dose higher than 500 mg/m2, is used to treat a range of adult and childhood cancers. Although HDMTX is safely administered to most patients, it can cause significant toxicity, including acute kidney injury (AKI) in 2%–12% of patients. Nephrotoxicity results from crystallization of methotrexate in the renal tubular lumen, leading to tubular toxicity. AKI and other toxicities of high-dose methotrexate can lead to significant morbidity, treatment delays, and diminished renal function. Risk factors for methotrexate-associated toxicity include a history of renal dysfunction, volume depletion, acidic urine, and drug interactions. Renal toxicity leads to impaired methotrexate clearance and prolonged exposure to toxic concentrations, which further worsen renal function and exacerbate nonrenal adverse events, including myelosuppression, mucositis, dermatologic toxicity, and hepatotoxicity. Serum creatinine, urine output, and serum methotrexate concentration are monitored to assess renal clearance, with concurrent hydration, urinary alkalinization, and leucovorin rescue to prevent and mitigate AKI and subsequent toxicity. When delayed methotrexate excretion or AKI occurs despite preventive strategies, increased hydration, high-dose leucovorin, and glucarpidase are usually sufficient to allow renal recovery without the need for dialysis. Prompt recognition and effective treatment of AKI and associated toxicities mitigate further toxicity, facilitate renal recovery, and permit patients to receive other chemotherapy or resume HDMTX therapy when additional courses are indicated. Implications for Practice: High-dose methotrexate (HDMTX), defined as a dose higher than 500 mg/m2, is used for a range of cancers. Although HDMTX is safely administered to most patients, it can cause significant toxicity, including acute kidney injury (AKI), attributable to crystallization of methotrexate in the renal tubular lumen, leading to tubular

  6. Determination of the uncertainties in radiation doses from ingestion of strontium-90

    NASA Astrophysics Data System (ADS)

    Apostoaei, Andrei Iulian

    Quantification of the uncertainties in the internal dosimetry is important because it can impact the outcome of dose reconstruction, risk assessment or epidemiological studies. This research focused on determination of the uncertainties in the dose factors from a single ingestion of 90Sr by adults, and analyzed the changes with age and the effect of gender. The uncertainties in the estimated dose factors are a factor of 6 for the bone surface, 5 for the red bone marrow, 2.5 for bladder and stomach, 2.2 for the small intestine, 2.1 for the upper large intestine and 2.7 for the lower large intestine. For the rest of the organs the uncertainty is a factor of 3. Only four parameters of the biokinetic model showed an age-dependency within the adult age group: the fractional transfers of strontium from plasma to cortical and trabecular bone, and the removal rates from the cortical and trabecular bone, respectively. When age-dependent biokinetic parameters were used, the estimated dose-factors are very close to the dose factors obtained using age-independent kinetics (within 40%). Thus, the dose factors based on age-independent parameters should suffice for most practical purposes. The dose factors and the associated uncertainties were also calculated as a function of age-at-exposure and attained age. These age dependent curves can be used for estimating doses from continuous intakes, or doses delivered over a limited portion of time. In addition to the committed dose, an expected dose is also estimated in this work. The expected dose is calculated using the dose rate weighted by the probability of surviving up to the age when the dose-rate is delivered. For exposure at young ages the expected dose and the committed dose are similar, but the committed dose decreases to zero when exposure occurs close to age 70, while the expected dose has elevated values pass age 70. No gender differences were found for bone surface, for red bone marrow, and the large intestine. The doses

  7. SRT and SBRT: Current practices for QA dosimetry and 3D

    NASA Astrophysics Data System (ADS)

    Benedict, S. H.; Cai, J.; Libby, B.; Lovelock, M.; Schlesinger, D.; Sheng, K.; Yang, W.

    2010-11-01

    The major feature that separates stereotactic radiation therapy (cranial SRT) and stereotactic body radiation therapy (SBRT) from conventional radiation treatment is the delivery of large doses in a few fractions which results in a high biological effective dose (BED). In order to minimize the normal tissue toxicity, quality assurance of the conformation of high doses to the target and rapid fall off doses away from the target is critical. The practice of SRT and SBRT therefore requires a high-level of confidence in the accuracy of the entire treatment delivery process. In SRT and SBRT confidence in this accuracy is accomplished by the integration of modern imaging, simulation, treatment planning and delivery technologies into all phases of the treatment process; from treatment simulation and planning and continuing throughout beam delivery. In this report some of the findings of Task group 101 of the AAPM will be presented which outlines the best-practice guidelines for SBRT. The task group report includes a review of the literature to identify reported clinical findings and expected outcomes for this treatment modality. Information in this task group is provided for establishing an SBRT program, including protocols, equipment, resources, and QA procedures.

  8. A Simulation Study of Methods for Selecting Subgroup-Specific Doses in Phase I Trials

    PubMed Central

    Morita, Satoshi; Thall, Peter F.; Takeda, Kentaro

    2016-01-01

    Summary Patient heterogeneity may complicate dose-finding in phase I clinical trials if the dose-toxicity curves differ between subgroups. Conducting separate trials within subgroups may lead to infeasibly small sample sizes in subgroups having low prevalence. Alternatively, it is not obvious how to conduct a single trial while accounting for heterogeneity. To address this problem, we consider a generalization of the continual reassessment method (O’Quigley, et al., 1990) based on a hierarchical Bayesian dose-toxicity model that borrows strength between subgroups under the assumption that the subgroups are exchangeable. We evaluate a design using this model that includes subgroup-specific dose selection and safety rules. A simulation study is presented that includes comparison of this method to three alternative approaches, based on non-hierarchical models, that make different types of assumptions about within-subgroup dose-toxicity curves. The simulations show that the hierarchical model-based method is recommended in settings where the dose-toxicity curves are exchangeable between subgroups. We present practical guidelines for application, and provide computer programs for trial simulation and conduct. PMID:28111916

  9. Implementing smart infusion pumps with dose-error reduction software: real-world experiences.

    PubMed

    Heron, Claire

    2017-04-27

    Intravenous (IV) drug administration, especially with 'smart pumps', is complex and susceptible to errors. Although errors can occur at any stage of the IV medication process, most errors occur during reconstitution and administration. Dose-error reduction software (DERS) loaded on to infusion pumps incorporates a drug library with predefined upper and lower drug dose limits and infusion rates, which can reduce IV infusion errors. Although this is an important advance for patient safety at the point of care, uptake is still relatively low. This article discuses the challenges and benefits of implementing DERS in clinical practice as experienced by three UK trusts.

  10. Palliative radiation therapy practice for advanced esophageal carcinoma in Africa.

    PubMed

    Sharma, V; Gaye, P M; Wahab, S A; Ndlovu, N; Ngoma, T; Vanderpuye, V; Sowuhami, A; Dawotola, D A; Kigula-Mugambe, J; Jeremic, B

    2010-04-01

    While numerous surveys of pattern of practices of palliative radiotherapy (RT) in advanced esophageal cancers have been published in developed countries, there is no such survey in African countries. During and after a regional training course by the International Atomic Energy Agency (IAEA) in palliative cancer care, a questionnaire was distributed to African RT centers to gather information about infrastructure and human resources available, and the pattern of practice of palliative RT for esophageal cancers. Twenty-four of the 35 centers (60%) completed the questionnaire. Twenty out of 23 (87%) centers treat patients with esophageal cancer presenting with dysphagia using external beam RT (16 centers external beam RT alone and 4 centers also use brachytherapy as a boost). Twelve (60%) centers prescribe RT doses of 30 Gy in 10 fractions and 2 centers 20 Gy in 5 fractions. Eighteen centers (78%) have low dose rate (LDR) brachytherapy, and 9 (39%) centers have high dose rate (HDR) brachytherapy. One center only used HDR brachytherapy alone to a dose of 16 Gy in 2 fractions over 8 days. RT remains a major component of treatment of patients with esophageal cancers in African countries. Still, there is a great variety among centers in both indications for RT and its characteristics for a treatment indication.

  11. Practical aspects and uncertainty analysis of biological effective dose (BED) regarding its three-dimensional calculation in multiphase radiotherapy treatment plans

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kauweloa, Kevin I., E-mail: Kauweloa@livemail.uthscsa.edu; Gutierrez, Alonso N.; Bergamo, Angelo

    2014-07-15

    Purpose: There is a growing interest in the radiation oncology community to use the biological effective dose (BED) rather than the physical dose (PD) in treatment plan evaluation and optimization due to its stronger correlation with radiobiological effects. Radiotherapy patients may receive treatments involving a single only phase or multiple phases (e.g., primary and boost). Since most treatment planning systems cannot calculate the analytical BED distribution in multiphase treatments, an approximate multiphase BED expression, which is based on the total physical dose distribution, has been used. The purpose of this paper is to reveal the mathematical properties of the approximatemore » BED formulation, relative to the true BED. Methods: The mathematical properties of the approximate multiphase BED equation are analyzed and evaluated. In order to better understand the accuracy of the approximate multiphase BED equation, the true multiphase BED equation was derived and the mathematical differences between the true and approximate multiphase BED equations were determined. The magnitude of its inaccuracies under common clinical circumstances was also studied. All calculations were performed on a voxel-by-voxel basis using the three-dimensional dose matrices. Results: Results showed that the approximate multiphase BED equation is accurate only when the dose-per-fractions (DPFs) in both the first and second phases are equal, which occur when the dose distribution does not significantly change between the phases. In the case of heterogeneous dose distributions, which significantly vary between the phases, there are fewer occurrences of equal DPFs and hence the inaccuracy of the approximate multiphase BED is greater. These characteristics are usually seen in the dose distributions being delivered to organs at risk rather than to targets. Conclusions: The finding of this study indicates that the true multiphase BED equation should be implemented in the treatment

  12. Technical Note: SCUDA: A software platform for cumulative dose assessment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Park, Seyoun; McNutt, Todd; Quon, Harry

    Purpose: Accurate tracking of anatomical changes and computation of actually delivered dose to the patient are critical for successful adaptive radiation therapy (ART). Additionally, efficient data management and fast processing are practically important for the adoption in clinic as ART involves a large amount of image and treatment data. The purpose of this study was to develop an accurate and efficient Software platform for CUmulative Dose Assessment (SCUDA) that can be seamlessly integrated into the clinical workflow. Methods: SCUDA consists of deformable image registration (DIR), segmentation, dose computation modules, and a graphical user interface. It is connected to our imagemore » PACS and radiotherapy informatics databases from which it automatically queries/retrieves patient images, radiotherapy plan, beam data, and daily treatment information, thus providing an efficient and unified workflow. For accurate registration of the planning CT and daily CBCTs, the authors iteratively correct CBCT intensities by matching local intensity histograms during the DIR process. Contours of the target tumor and critical structures are then propagated from the planning CT to daily CBCTs using the computed deformations. The actual delivered daily dose is computed using the registered CT and patient setup information by a superposition/convolution algorithm, and accumulated using the computed deformation fields. Both DIR and dose computation modules are accelerated by a graphics processing unit. Results: The cumulative dose computation process has been validated on 30 head and neck (HN) cancer cases, showing 3.5 ± 5.0 Gy (mean±STD) absolute mean dose differences between the planned and the actually delivered doses in the parotid glands. On average, DIR, dose computation, and segmentation take 20 s/fraction and 17 min for a 35-fraction treatment including additional computation for dose accumulation. Conclusions: The authors developed a unified software platform that

  13. Practice patterns of radiotherapy in cervical cancer among member groups of the Gynecologic Cancer Intergroup (GCIG).

    PubMed

    Gaffney, David K; Du Bois, Andreas; Narayan, Kailash; Reed, Nick; Toita, Takafumi; Pignata, Sandro; Blake, Peter; Portelance, Lorraine; Sadoyze, Azmat; Pötter, Richard; Colombo, Alessandro; Randall, Marcus; Mirza, Mansoor R; Trimble, Edward L

    2007-06-01

    The aim of this study was to describe radiotherapeutic practice of the treatment of cervical cancer in member groups of the Gynecologic Cancer Intergroup (GCIG). A survey was developed and distributed to the members of the GCIG focusing on details of radiotherapy practice. Different scenarios were queried including advanced cervical cancer, postoperative patients, and para-aortic-positive lymph node cases. Items focused on indications for radiation therapy, radiation fields, dose, use of chemotherapy, brachytherapy and others. The cooperative groups from North America were compared with the other groups to evaluate potential differences in radiotherapy doses. A total of 39 surveys were returned from 13 different cooperative groups. For the treatment of advanced cervical cancer, external beam pelvic doses and total doses to point A were 47 + 3.5 Gy (mean + SD) and 79.1 + 7.9 Gy, respectively. Point A doses were not different between the North American cooperative groups compared with the others (p = 0.103). All groups used concomitant chemotherapy, with 30 of 36 respondents using weekly cisplatin. Of 33 respondents, 31 intervened for a low hemoglobin level. For a para-aortic field, the upper border was most commonly (15 of 24) at the T12-L1 interspace. Maintenance chemotherapy (after radiotherapy) was not performed by 68% of respondents. For vaginal brachytherapy after hysterectomy, 23 groups performed HDR brachytherapy and four groups used LDR brachytherapy. In the use of brachytherapy, there was no uniformity in dose prescription. Radiotherapy practices among member groups of the GCIG are similar in terms of both doses and use of chemotherapy.

  14. Dose mapping inside a gamma irradiator measured with doped silica fibre dosimetry and Monte Carlo simulation

    NASA Astrophysics Data System (ADS)

    Moradi, F.; Khandaker, M. U.; Mahdiraji, G. A.; Ung, N. M.; Bradley, D. A.

    2017-11-01

    In recent years doped silica fibre thermoluminescent dosimeters (TLD) have been demonstrated to have considerable potential for irradiation applications, benefitting from the available sensitivity, spatial resolution and dynamic dose range, with primary focus being on the needs of medical dosimetry. Present study concerns the dose distribution inside a cylindrically shaped gamma-ray irradiator cavity, with irradiator facilities such as the familiar 60Co versions being popularly used in industrial applications. Quality assurance of the radiation dose distribution inside the irradiation cell of such a device is of central importance in respect of the delivered dose to the irradiated material. Silica fibre TLD dose-rates obtained within a Gammacell-220 irradiator cavity show the existence of non-negligible dose distribution heterogeneity, by up to 20% and 26% in the radial and axial directions respectively, Monte Carlo simulations and available literature providing some support for present findings. In practice, it is evident that there is need to consider making corrections to nominal dose-rates in order to avoid the potential for under-dosing.

  15. Occupational radiation procedures and doses in South Korean dentists.

    PubMed

    Kim, Yoon-Ji; Cha, Eun Shil; Lee, Won Jin

    2016-10-01

    Dentistry is among the occupations involving chronic exposure to ionizing radiation. Although several cohort studies on medical radiation workers have been conducted in some countries, only a few epidemiological studies on dentists have been performed to examine occupational radiation exposure worldwide. The aim of this study was to investigate occupational characteristics and radiation exposures in South Korean dentists. A total of 658 dentists were surveyed from April 2012 to May 2013, and survey data were linked with dosimetry data from the National Dose Registry. Multiple linear regression analysis was used to identify the relationship between demographic or occupational factors and individual radiation doses. Of the dentists sampled, 78% were men, 51% were younger than age 40, and 61% began employment after 2000. The most frequent procedures performed by dentists were panoramic radiography, followed by intraoral and portable dental radiography. Male dentists were more frequently involved in radiation procedures, and a higher proportion of male than female dentists wore a lead apron for diagnostic radiology. The average annual effective dose was 0.18 mSv for male and 0.13 mSv for female dentists. Female dentists working in provincial areas had significantly higher average annual and cumulative effective doses than those in metropolitan areas. The cumulative effective doses were significantly greater for older dentists, those who entered the field in the 1990s, and those with longer employment duration. Our findings provided detailed information on work practices, number of procedures performed on a weekly basis, and occupational radiation doses, which enabled in-depth evaluation of occupational radiation exposure and work status among dentists. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. Isobio software: biological dose distribution and biological dose volume histogram from physical dose conversion using linear-quadratic-linear model.

    PubMed

    Jaikuna, Tanwiwat; Khadsiri, Phatchareewan; Chawapun, Nisa; Saekho, Suwit; Tharavichitkul, Ekkasit

    2017-02-01

    To develop an in-house software program that is able to calculate and generate the biological dose distribution and biological dose volume histogram by physical dose conversion using the linear-quadratic-linear (LQL) model. The Isobio software was developed using MATLAB version 2014b to calculate and generate the biological dose distribution and biological dose volume histograms. The physical dose from each voxel in treatment planning was extracted through Computational Environment for Radiotherapy Research (CERR), and the accuracy was verified by the differentiation between the dose volume histogram from CERR and the treatment planning system. An equivalent dose in 2 Gy fraction (EQD 2 ) was calculated using biological effective dose (BED) based on the LQL model. The software calculation and the manual calculation were compared for EQD 2 verification with pair t -test statistical analysis using IBM SPSS Statistics version 22 (64-bit). Two and three-dimensional biological dose distribution and biological dose volume histogram were displayed correctly by the Isobio software. Different physical doses were found between CERR and treatment planning system (TPS) in Oncentra, with 3.33% in high-risk clinical target volume (HR-CTV) determined by D 90% , 0.56% in the bladder, 1.74% in the rectum when determined by D 2cc , and less than 1% in Pinnacle. The difference in the EQD 2 between the software calculation and the manual calculation was not significantly different with 0.00% at p -values 0.820, 0.095, and 0.593 for external beam radiation therapy (EBRT) and 0.240, 0.320, and 0.849 for brachytherapy (BT) in HR-CTV, bladder, and rectum, respectively. The Isobio software is a feasible tool to generate the biological dose distribution and biological dose volume histogram for treatment plan evaluation in both EBRT and BT.

  17. SU-F-I-36: In-Utero Dose Measurements Within Postmortem Subjects for Estimating Fetal Doses in Pregnant Patients Examined with Pulmonary Embolism, Trauma, and Appendicitis CT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lipnharski, I; Quails, N; Carranza, C

    Purpose: The imaging of pregnant patients is medically necessary in certain clinical situations. The purpose of this work was to directly measure uterine doses in a cadaver scanned with CT protocols commonly performed on pregnant patients in order to estimate fetal dose and assess potential risk. Method: One postmortem subject was scanned on a 320-slice CT scanner with standard pulmonary embolism, trauma, and appendicitis protocols. All protocols were performed with the scan parameters and ranges currently used in clinical practice. Exams were performed both with and without iterative reconstruction to highlight the dose savings potential. Optically stimulated luminescent dosimeters (OSLDs)more » were inserted into the uterus in order to approximate fetal doses. Results: In the pulmonary embolism CT protocol, the uterus is outside of the primary beam, and the dose to the uterus was under 1 mGy. In the trauma and appendicitis protocols, the uterus is in the primary beam, the fetal dose estimates were 30.5 mGy for the trauma protocol, and 20.6 mGy for the appendicitis protocol. Iterative reconstruction reduced fetal doses by 30%, with uterine doses at 21.3 for the trauma and 14.3 mGy for the appendicitis protocol. Conclusion: Fetal doses were under 1 mGy when exposed to scatter radiation, and under 50 mGy when exposed to primary radiation with the trauma and appendicitis protocols. Consistent with the National Council on Radiation Protection & Measurements (NCRP) and the International Commission on Radiological Protection (ICRP), these doses exhibit a negligible risk to the fetus, with only a small increased risk of cancer. Still, CT scans are not recommended during pregnancy unless the benefits of the exam clearly outweigh the potential risk. Furthermore, when possible, pregnant patients should be examined on CT scanners equipped with iterative reconstruction in order to keep patient doses as low as reasonable achievable.« less

  18. Gender Differences in Radiation Dose from Nuclear Cardiology Studies Across the World: Findings from the International Atomic Energy Agency Nuclear Cardiology Protocols Study (INCAPS) Registry

    PubMed Central

    Shi, Lynn; Dorbala, Sharmila; Paez, Diana; Shaw, Leslee J.; Zukotynski, Katherine A.; Pascual, Thomas N. B.; Karthikeyan, Ganesan; Vitola, João V.; Better, Nathan; Bokhari, Nadia; Rehani, Madan M.; Kashyap, Ravi; Dondi, Maurizio; Mercuri, Mathew; Einstein, Andrew J.

    2016-01-01

    OBJECTIVES The aim of this study was to investigate gender-based differences in nuclear cardiology practice, globally, with particular focus on laboratory volume, radiation dose, protocols, and best practices. BACKGROUND It is unclear if gender-based differences exist in radiation exposure for nuclear cardiology procedures. METHODS In a large multicenter observational cross-sectional study encompassing 7911 patients in 65 countries, radiation effective dose was estimated for each examination. Patient-level best practices relating to radiation exposure were compared between genders. Analysis of covariance was utilized to determine any difference in radiation exposure according to gender, region, and the interaction between gender and region. Linear, logistic, and hierarchical regression models were developed to evaluate gender-based differences in radiation exposure and laboratory adherence to best practices. We also included the United Nations’ gender inequality and human development indices as covariates in multivariable models. RESULTS The proportion of MPI studies performed in women varied between countries, however there was no significant correlation with gender inequality index. Globally, mean effective dose for nuclear cardiology procedures was only slightly lower in women (9.6±4.5 mSv) than in men (10.3±4.5 mSv men, p<0.001), with a difference of only 0.3 mSv in a multivariable model adjusting for patient age and weight. Stress-only imaging was performed more frequently in women (12.5% vs. 8.4%, p<0.001), however camera-based dose-reduction strategies were used less frequently in women (58.6% vs. 65.5%, p<0.001). CONCLUSIONS Despite significant worldwide variation in best practice use and radiation doses from nuclear cardiology procedures, only small differences were observed between genders worldwide. Regional variations noted in MPI use and radiation dose offer potential opportunities to address gender-related differences in delivery of nuclear

  19. Clinical application of Chamomilla recutita in phlebitis: dose response curve study.

    PubMed

    Reis, Paula Elaine Diniz Dos; Carvalho, Emilia Campos de; Bueno, Paula Carolina Pires; Bastos, Jairo Kenupp

    2011-01-01

    This experimental and dose-response curve study aimed to carry out the quality control of the Chamomilla recutita sample, as well as to estimate the ideal dose, for anti-inflammatory effect, of the extract of its capitula, in patients with phlebitis due to peripheral intravenous infusion of antineoplastic chemotherapy and to evaluate the toxicity of this extract in human beings. The therapeutic efficacy, concerning the anti-inflammatory potential, of different doses of Chamomilla recutita extract were analyzed and compared in 25 patients. The time of regression of phlebitis was shorter for groups with 2.5% concentration (mean=29.2h, standard deviation = 8.98) and 5% concentration (mean = 38.8h, standard deviation = 17.47). Local toxicity was almost not observed. This research contributes to the innovation of the nursing clinical practice, since it suggests an alternative for the treatment of phlebitis through the clinical use of phytotherapeutic drugs.

  20. The incidence of phlebitis with intravenous amiodarone at guideline dose recommendations.

    PubMed

    Slim, Ahmad M; Roth, Jason E; Duffy, Benjamin; Boyd, Sheri Y N; Rubal, Bernard J

    2007-12-01

    Postoperative atrial fibrillation following cardiothoracic surgery is common and frequently managed with intravenous (IV) amiodarone. Phlebitis is the most common complication with peripheral infusion of this agent. Current practice guidelines for peripheral IV administration of <2 mg/mL amiodarone were established to reduce the risk of phlebitis. The present study examines the incidence of phlebitis in a postoperative patient population given current dose recommendations. A total of 273 patient charts were reviewed. The incidence of phlebitis in patients given IV amiodarone (n = 36) was 13.9% (95% confidence interval, 2.6-25.2%; p = 0.001). Logistic regression analysis with backward elimination of other therapeutic risk factors suggests that the odds ratio for phlebitis using current dose regimens without IV filters is 19-fold greater than baseline risk in this population. Phlebitis remains a significant complication associated with peripheral infusion of amiodarone within recommended dosing limits.

  1. 75 FR 81849 - Office of the Attorney General; Applicability of the Sex Offender Registration and Notification Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-29

    ... convictions would violate the Constitution's prohibition of ex post facto laws or other provisions of the... purposes, and accordingly do not implicate the Constitution's prohibition of ex post facto laws. See 42 U.S... distinction for ex post facto purposes between the SORNA requirements and the sex offender registration and...

  2. The benefit of low dose prophylaxis in the treatment of hemophilia: a focus on China.

    PubMed

    Wu, Runhui; Luke, Koon Hung

    2017-11-01

    Currently full dose prophylaxis is the standard of care in the treatment of hemophilia (World Federation of Hemophilia). However, the high costs prevent the use of standard or intermediate dose prophylaxis in China and other developing countries. Low dose prophylaxis would be a viable alternative treatment. At present global research data on the use of low dose prophylaxis is limited. Areas covered: Since 2007, China has been developing low dose prophylaxis as a high priority (90 % of moderate and severe hemophilia boys suffer joint disease by age 6 - 9). 11 studies were successfully conducted and published results showing evidence of the benefits of low dose prophylaxis to reduce joint bleeding. This new knowledge has been implemented into clinical practice in China. However the long-term outcome of arthropathy remains unclear and obstacles in execution exist. Expert commentary: In 2016, the first phenotype-based individualized prophylaxis study using four escalating low dose regimens on severe Chinese hemophilia A boys (China Individualized Prophylaxis Study (CHIP China)) launched. Using the previously published and imminent CHIP data, the goal for China is to establish an effective escalating low dose prophylaxis protocol for use in China as a standard of care.

  3. Dose Equivalents for Second-Generation Antipsychotic Drugs: The Classical Mean Dose Method

    PubMed Central

    Leucht, Stefan; Samara, Myrto; Heres, Stephan; Patel, Maxine X.; Furukawa, Toshi; Cipriani, Andrea; Geddes, John; Davis, John M.

    2015-01-01

    Background: The concept of dose equivalence is important for many purposes. The classical approach published by Davis in 1974 subsequently dominated textbooks for several decades. It was based on the assumption that the mean doses found in flexible-dose trials reflect the average optimum dose which can be used for the calculation of dose equivalence. We are the first to apply the method to second-generation antipsychotics. Methods: We searched for randomized, double-blind, flexible-dose trials in acutely ill patients with schizophrenia that examined 13 oral second-generation antipsychotics, haloperidol, and chlorpromazine (last search June 2014). We calculated the mean doses of each drug weighted by sample size and divided them by the weighted mean olanzapine dose to obtain olanzapine equivalents. Results: We included 75 studies with 16 555 participants. The doses equivalent to 1 mg/d olanzapine were: amisulpride 38.3 mg/d, aripiprazole 1.4 mg/d, asenapine 0.9 mg/d, chlorpromazine 38.9 mg/d, clozapine 30.6 mg/d, haloperidol 0.7 mg/d, quetiapine 32.3mg/d, risperidone 0.4mg/d, sertindole 1.1 mg/d, ziprasidone 7.9 mg/d, zotepine 13.2 mg/d. For iloperidone, lurasidone, and paliperidone no data were available. Conclusions: The classical mean dose method is not reliant on the limited availability of fixed-dose data at the lower end of the effective dose range, which is the major limitation of “minimum effective dose methods” and “dose-response curve methods.” In contrast, the mean doses found by the current approach may have in part depended on the dose ranges chosen for the original trials. Ultimate conclusions on dose equivalence of antipsychotics will need to be based on a review of various methods. PMID:25841041

  4. Improving the estimation of mealtime insulin dose in adults with type 1 diabetes: the Normal Insulin Demand for Dose Adjustment (NIDDA) study.

    PubMed

    Bao, Jiansong; Gilbertson, Heather R; Gray, Robyn; Munns, Diane; Howard, Gabrielle; Petocz, Peter; Colagiuri, Stephen; Brand-Miller, Jennie C

    2011-10-01

    Although carbohydrate counting is routine practice in type 1 diabetes, hyperglycemic episodes are common. A food insulin index (FII) has been developed and validated for predicting the normal insulin demand generated by mixed meals in healthy adults. We sought to compare a novel algorithm on the basis of the FII for estimating mealtime insulin dose with carbohydrate counting in adults with type 1 diabetes. A total of 28 patients using insulin pump therapy consumed two different breakfast meals of equal energy, glycemic index, fiber, and calculated insulin demand (both FII = 60) but approximately twofold difference in carbohydrate content, in random order on three consecutive mornings. On one occasion, a carbohydrate-counting algorithm was applied to meal A (75 g carbohydrate) for determining bolus insulin dose. On the other two occasions, carbohydrate counting (about half the insulin dose as meal A) and the FII algorithm (same dose as meal A) were applied to meal B (41 g carbohydrate). A real-time continuous glucose monitor was used to assess 3-h postprandial glycemia. Compared with carbohydrate counting, the FII algorithm significantly decreased glucose incremental area under the curve over 3 h (-52%, P = 0.013) and peak glucose excursion (-41%, P = 0.01) and improved the percentage of time within the normal blood glucose range (4-10 mmol/L) (31%, P = 0.001). There was no significant difference in the occurrence of hypoglycemia. An insulin algorithm based on physiological insulin demand evoked by foods in healthy subjects may be a useful tool for estimating mealtime insulin dose in patients with type 1 diabetes.

  5. Review of nuclear pharmacy practice in hospitals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kawada, T.K.; Tubis, M.; Ebenkamp, T.

    1982-02-01

    An operational profile for nuclear pharmacy practice is presented, and the technical and professional role of nuclear pharmacists is reviewed. Key aspects of nuclear pharmacy practice in hospitals discussed are the basic facilities and equipment for the preparation, quality control, and distribution of radioactive drug products. Standards for receiving, storing, and processing radioactive material are described. The elements of a radiopharmaceutical quality assurance program, including the working procedures, documentation systems, data analysis, and specific control tests, are presented. Details of dose preparation and administration and systems of inventory control for radioactive products are outlined.

  6. A novel method for the evaluation of uncertainty in dose-volume histogram computation.

    PubMed

    Henríquez, Francisco Cutanda; Castrillón, Silvia Vargas

    2008-03-15

    Dose-volume histograms (DVHs) are a useful tool in state-of-the-art radiotherapy treatment planning, and it is essential to recognize their limitations. Even after a specific dose-calculation model is optimized, dose distributions computed by using treatment-planning systems are affected by several sources of uncertainty, such as algorithm limitations, measurement uncertainty in the data used to model the beam, and residual differences between measured and computed dose. This report presents a novel method to take them into account. To take into account the effect of associated uncertainties, a probabilistic approach using a new kind of histogram, a dose-expected volume histogram, is introduced. The expected value of the volume in the region of interest receiving an absorbed dose equal to or greater than a certain value is found by using the probability distribution of the dose at each point. A rectangular probability distribution is assumed for this point dose, and a formulation that accounts for uncertainties associated with point dose is presented for practical computations. This method is applied to a set of DVHs for different regions of interest, including 6 brain patients, 8 lung patients, 8 pelvis patients, and 6 prostate patients planned for intensity-modulated radiation therapy. Results show a greater effect on planning target volume coverage than in organs at risk. In cases of steep DVH gradients, such as planning target volumes, this new method shows the largest differences with the corresponding DVH; thus, the effect of the uncertainty is larger.

  7. Hormones and Endocrine-Disrupting Chemicals: Low-Dose Effects and Nonmonotonic Dose Responses

    PubMed Central

    Colborn, Theo; Hayes, Tyrone B.; Heindel, Jerrold J.; Jacobs, David R.; Lee, Duk-Hee; Shioda, Toshi; Soto, Ana M.; vom Saal, Frederick S.; Welshons, Wade V.; Zoeller, R. Thomas

    2012-01-01

    For decades, studies of endocrine-disrupting chemicals (EDCs) have challenged traditional concepts in toxicology, in particular the dogma of “the dose makes the poison,” because EDCs can have effects at low doses that are not predicted by effects at higher doses. Here, we review two major concepts in EDC studies: low dose and nonmonotonicity. Low-dose effects were defined by the National Toxicology Program as those that occur in the range of human exposures or effects observed at doses below those used for traditional toxicological studies. We review the mechanistic data for low-dose effects and use a weight-of-evidence approach to analyze five examples from the EDC literature. Additionally, we explore nonmonotonic dose-response curves, defined as a nonlinear relationship between dose and effect where the slope of the curve changes sign somewhere within the range of doses examined. We provide a detailed discussion of the mechanisms responsible for generating these phenomena, plus hundreds of examples from the cell culture, animal, and epidemiology literature. We illustrate that nonmonotonic responses and low-dose effects are remarkably common in studies of natural hormones and EDCs. Whether low doses of EDCs influence certain human disorders is no longer conjecture, because epidemiological studies show that environmental exposures to EDCs are associated with human diseases and disabilities. We conclude that when nonmonotonic dose-response curves occur, the effects of low doses cannot be predicted by the effects observed at high doses. Thus, fundamental changes in chemical testing and safety determination are needed to protect human health. PMID:22419778

  8. Hard beta and gamma emissions of 124I. Impact on occupational dose in PET/CT.

    PubMed

    Kemerink, G J; Franssen, R; Visser, M G W; Urbach, C J A; Halders, S G E A; Frantzen, M J; Brans, B; Teule, G J J; Mottaghy, F M

    2011-01-01

    The hard beta and gamma radiation of 124I can cause high doses to PET/CT workers. In this study we tried to quantify this occupational exposure and to optimize radioprotection. Thin MCP-Ns thermoluminescent dosimeters suitable for measuring beta and gamma radiation were used for extremity dosimetry, active personal dosimeters for whole-body dosimetry. Extremity doses were determined during dispensing of 124I and oral administration of the activity to the patient, the body dose during all phases of the PET/CT procedure. In addition, dose rates of vials and syringes as used in clinical practice were measured. The procedure for dispensing 124I was optimized using newly developed shielding. Skin dose rates up to 100 mSv/min were measured when in contact with the manufacturer's vial containing 370 MBq of 124I. For an unshielded 5 ml syringe the positron skin dose was about seven times the gamma dose. Before optimization of the preparation of 124I, using an already reasonably safe technique, the highest mean skin dose caused by handling 370 MBq was 1.9 mSv (max. 4.4 mSv). After optimization the skin dose was below 0.2 mSv. The highly energetic positrons emitted by 124I can cause high skin doses if radioprotection is poor. Under optimized conditions occupational doses are acceptable. Education of workers is of paramount importance.

  9. Imaging doses in radiation therapy from kilovoltage cone-beam computed tomography

    NASA Astrophysics Data System (ADS)

    Hyer, Daniel Ellis

    Advances in radiation treatment delivery, such as intensity modulated radiation therapy (IMRT), have made it possible to deliver large doses of radiation with a high degree of conformity. While highly conformal treatments offers the advantage of sparing surrounding normal tissue, this benefit can only be realized if the patient is accurately positioned during each treatment fraction. The need to accurately position the patient has led to the development and use of gantry mounted kilovoltage cone-beam computed tomography (kV-CBCT) systems. These systems are used to acquire high resolution volumetric images of the patient which are then digitally registered with the planning CT dataset to confirm alignment of the patient on the treatment table. While kV-CBCT is a very useful tool for aligning the patient prior to treatment, daily use in a high fraction therapy regimen results in a substantial radiation dose. In order to quantify the radiation dose associated with CBCT imaging, an anthropomorphic phantom representing a 50th percentile adult male and a fiber-optic coupled (FOC) dosimetry system were both constructed as part of this dissertation. These tools were then used to directly measure organ doses incurred during clinical protocols for the head, chest, and pelvis. For completeness, the dose delivered from both the X-ray Volumetric Imager (XVI, Elekta Oncology Systems, Crawley, UK) and the On-Board Imager (OBI, Varian Medical Systems, Palo Alto, CA) were investigated. While this study provided a direct measure of organ doses for estimating risk to the patient, a practical method for estimating organ doses that could be performed with phantoms and dosimeters currently available at most clinics was also desired. To accomplish this goal, a 100 mm pencil ion chamber was used to measure the "cone beam dose index" (CBDI) inside standard CT dose index (CTDI) acrylic phantoms. A weighted CBDI (CBDIw), similar to the weighted CT dose index (CTDIw), was then calculated to

  10. 78 FR 51821 - Sentencing Guidelines for United States Courts

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-21

    ... inserting ``However, the Supreme Court has held that the ex post facto clause applies to sentencing.... Ct. 2072, 2078 (2013) (holding that 'there is an ex post facto violation when a defendant is... ex post facto clause, in which case the court shall apply the Guidelines Manual in effect on the date...

  11. Pulmonary embolism in pediatric patients survey of CT pulmonary angiography practices and policies.

    PubMed

    Lee, Edward Y; Zurakowski, David; Boiselle, Phillip M

    2010-12-01

    To determine the current policies and practices of Society for Pediatric Radiology (SPR) members regarding the evaluation of pediatric patients with suspected pulmonary embolism (PE) with an emphasis on use of computed tomography pulmonary angiography (CTPA). Institutional review board exemption was granted for this study. Surveys were mailed electronically to the 1575 members of the SPR representing 416 institutions. Information gathered included the existence of written policies, the imaging study of choice for suspected PE, routine acquisition of chest radiographs before CTPA, currently used CTPA techniques, modifications of protocols for radiation dose reduction, typical DLP (dose-length-product) for CTPA, and estimated annual frequency of performing CTPA for evaluating PE in children. Survey items pertaining to policies and practices were compared between practice settings and populations using chi-square analysis. One hundred and sixty members representing 118 institutions responded, which resulted in a response rate of 28% (118/416), on an institutional basis. Of these 118 respondents, 104 (88%) perform CTPA in children with clinical suspicion of PE. Of the 104 respondents who perform CTPA, 26 (25%) have a written policy for CTPA, 93 (89%) perform CTPA as the first study choice, and 67 (64%) routinely obtain chest radiographs before CTPA. The most commonly used CTPA techniques in children with clinical suspicion of PE include intravenous contrast amount of 2 mL/kg, mechanical injection of intravenous contrast, and tailored bolus tracking method for CTPA scan initiation by observing the Hounsfield units of contrast in the central pulmonary artery on the monitoring scan. Sixty respondents (58%) modify CTPA imaging protocols for evaluating PE in children in order to decrease radiation dose. The two most common modifications for radiation dose reduction were reduced mAs in 41 (68%) and automatic exposure control in 38 (63%). The majority of respondents (88%) did

  12. The influence of patient centering on CT dose and image noise.

    PubMed

    Toth, Thomas; Ge, Zhanyu; Daly, Michael P

    2007-07-01

    Although x-ray intensity shaping filters (bowtie filters) have been used since the introduction of some of the earliest CT scanner models, the clinical implications on dose and noise are not well understood. To achieve the intended dose and noise advantage requires the patient to be centered in the scan field of view. In this study we explore the implications of patient centering in clinical practice. We scanned various size and shape phantoms on a GE LightSpeed VCT scanner using each available source filter with the phantom centers positioned at 0, 3, and 6 cm below the center of rotation (isocenter). Surface doses were measured along with image noise over a large image region. Regression models of surface dose and noise were generated as a function of phantom size and centering error. Methods were also developed to determine the amount of miscentering using a scout scan projection radiograph (SPR). These models were then used to retrospectively evaluate 273 adult body patients for clinical implications. When miscentered by 3 and 6 cm, the surface dose on a 32 cm CTDI phantom increased by 18% and 41% while image noise also increased by 6% and 22%. The retrospective analysis of adult body scout SPR scans shows that 46% of patients were miscentered in elevation by 20-60 mm with a mean position 23 mm below the center of rotation (isocenter). The analysis indicated a surface dose penalty of up to 140% with a mean dose penalty of 33% assuming that tube current is increased to compensate for the increased noise due to miscentering. Clinical image quality and dose efficiency can be improved on scanners with bowtie filters if care is exercised when positioning patients. Automatically providing patient specific centering and scan parameter selection information can help the technologist improve workflow, achieve more consistent image quality and reduce patient dose.

  13. A computer program for calculation of approximate embryo/fetus radiation dose in nuclear medicine applications.

    PubMed

    Bayram, Tuncay; Sönmez, Bircan

    2012-04-01

    In this study, we aimed to make a computer program that calculates approximate radiation dose received by embryo/fetus in nuclear medicine applications. Radiation dose values per MBq-1 received by embryo/fetus in nuclear medicine applications were gathered from literature for various stages of pregnancy. These values were embedded in the computer code, which was written in Fortran 90 program language. The computer program called nmfdose covers almost all radiopharmaceuticals used in nuclear medicine applications. Approximate radiation dose received by embryo/fetus can be calculated easily at a few steps using this computer program. Although there are some constraints on using the program for some special cases, nmfdose is useful and it provides practical solution for calculation of approximate dose to embryo/fetus in nuclear medicine applications. None declared.

  14. Current worldwide nuclear cardiology practices and radiation exposure: results from the 65 country IAEA Nuclear Cardiology Protocols Cross-Sectional Study (INCAPS).

    PubMed

    Einstein, Andrew J; Pascual, Thomas N B; Mercuri, Mathew; Karthikeyan, Ganesan; Vitola, João V; Mahmarian, John J; Better, Nathan; Bouyoucef, Salah E; Hee-Seung Bom, Henry; Lele, Vikram; Magboo, V Peter C; Alexánderson, Erick; Allam, Adel H; Al-Mallah, Mouaz H; Flotats, Albert; Jerome, Scott; Kaufmann, Philipp A; Luxenburg, Osnat; Shaw, Leslee J; Underwood, S Richard; Rehani, Madan M; Kashyap, Ravi; Paez, Diana; Dondi, Maurizio

    2015-07-07

    To characterize patient radiation doses from nuclear myocardial perfusion imaging (MPI) and the use of radiation-optimizing 'best practices' worldwide, and to evaluate the relationship between laboratory use of best practices and patient radiation dose. We conducted an observational cross-sectional study of protocols used for all 7911 MPI studies performed in 308 nuclear cardiology laboratories in 65 countries for a single week in March-April 2013. Eight 'best practices' relating to radiation exposure were identified a priori by an expert committee, and a radiation-related quality index (QI) devised indicating the number of best practices used by a laboratory. Patient radiation effective dose (ED) ranged between 0.8 and 35.6 mSv (median 10.0 mSv). Average laboratory ED ranged from 2.2 to 24.4 mSv (median 10.4 mSv); only 91 (30%) laboratories achieved the median ED ≤ 9 mSv recommended by guidelines. Laboratory QIs ranged from 2 to 8 (median 5). Both ED and QI differed significantly between laboratories, countries, and world regions. The lowest median ED (8.0 mSv), in Europe, coincided with high best-practice adherence (mean laboratory QI 6.2). The highest doses (median 12.1 mSv) and low QI (4.9) occurred in Latin America. In hierarchical regression modelling, patients undergoing MPI at laboratories following more 'best practices' had lower EDs. Marked worldwide variation exists in radiation safety practices pertaining to MPI, with targeted EDs currently achieved in a minority of laboratories. The significant relationship between best-practice implementation and lower doses indicates numerous opportunities to reduce radiation exposure from MPI globally. © The Author 2015. Published by Oxford University Press on behalf of the European Society of Cardiology.

  15. 128 slice computed tomography dose profile measurement using thermoluminescent dosimeter

    NASA Astrophysics Data System (ADS)

    Salehhon, N.; Hashim, S.; Karim, M. K. A.; Ang, W. C.; Musa, Y.; Bahruddin, N. A.

    2017-05-01

    The increasing use of computed tomography (CT) in clinical practice marks the needs to understand the dose descriptor and dose profile. The purposes of the current study were to determine the CT dose index free-in-air (CTDIair) in 128 slice CT scanner and to evaluate the single scan dose profile (SSDP). Thermoluminescent dosimeters (TLD-100) were used to measure the dose profile of the scanner. There were three sets of CT protocols where the tube potential (kV) setting was manipulated for each protocol while the rest of parameters were kept constant. These protocols were based from routine CT abdominal examinations for male adult abdomen. It was found that the increase of kV settings made the values of CTDIair increased as well. When the kV setting was changed from 80 kV to 120 kV and from 120 kV to 140 kV, the CTDIair values were increased as much as 147.9% and 53.9% respectively. The highest kV setting (140 kV) led to the highest CTDIair value (13.585 mGy). The p-value of less than 0.05 indicated that the results were statistically different. The SSDP showed that when the kV settings were varied, the peak sharpness and height of Gaussian function profiles were affected. The full width at half maximum (FWHM) of dose profiles for all protocols were coincided with the nominal beam width set for the measurements. The findings of the study revealed much information on the characterization and performance of 128 slice CT scanner.

  16. WE-AB-207B-06: Dose and Biological Uncertainties in Sarcoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marteinsdottir, M; University of Iceland, Reykjavik; Schuemann, J

    2016-06-15

    Purpose: To understand the clinical impact of key uncertainties in proton therapy potentially affecting the analysis of clinical trials, namely the assumption of using a constant relative biological effectiveness (RBE) of 1.1 compared to variable RBE for proton therapy and the use of analytical dose calculation (ADC) methods. Methods: Proton dose distributions were compared for analytical and Monte Carlo (TOPAS) dose calculations. In addition, differences between using a constant RBE of 1.1 (RBE-constant) were compared with four different RBE models (to assess model variations). 10 patients were selected from an ongoing clinical trial on IMRT versus scanned protons for sarcoma.more » Comparisons were performed using dosimetric indices based on dose-volume histogram analyses and γ-index analyses. Results: For three of the RBE-models the mean dose, D95, D50 and D02 (dose values covering 95%, 50% and 2% of the target volume, respectively) were up to 5% lower than for RBE-constant. The dosimetric indices for one of the RBE-models were around 9% lower than for the RBE-constant model. The differences for V90 (the percentage of the target volume covered by 90% of the prescription dose) were up to 40% for three RBE-models, whereas for one the difference was around 95%. All ADC dosimetric indices were up to 5% larger than for RBE-constant. The γ-index passing rate for the target volume with a 3%/3mm criterion was above 97% for all models except for one, which was below 24%. Conclusion: Interpretation of clinical trials on sarcoma may depend on dose calculation uncertainties (as assessed by Monte Carlo). In addition, the biological dose distribution depends notably on which RBE model is utilized. The current practice of using a constant RBE of 1.1 may overestimate the target dose by as much as 5% for biological dose calculations. Performing an RBE uncertainty analysis is recommended for trial analysis. U19 projects - U19 CA 021239. PI: Delaney.« less

  17. Organ dose conversion coefficients for tube current modulated CT protocols for an adult population

    NASA Astrophysics Data System (ADS)

    Fu, Wanyi; Tian, Xiaoyu; Sahbaee, Pooyan; Zhang, Yakun; Segars, William Paul; Samei, Ehsan

    2016-03-01

    In computed tomography (CT), patient-specific organ dose can be estimated using pre-calculated organ dose conversion coefficients (organ dose normalized by CTDIvol, h factor) database, taking into account patient size and scan coverage. The conversion coefficients have been previously estimated for routine body protocol classes, grouped by scan coverage, across an adult population for fixed tube current modulated CT. The coefficients, however, do not include the widely utilized tube current (mA) modulation scheme, which significantly impacts organ dose. This study aims to extend the h factors and the corresponding dose length product (DLP) to create effective dose conversion coefficients (k factor) database incorporating various tube current modulation strengths. Fifty-eight extended cardiac-torso (XCAT) phantoms were included in this study representing population anatomy variation in clinical practice. Four mA profiles, representing weak to strong mA dependency on body attenuation, were generated for each phantom and protocol class. A validated Monte Carlo program was used to simulate the organ dose. The organ dose and effective dose was further normalized by CTDIvol and DLP to derive the h factors and k factors, respectively. The h factors and k factors were summarized in an exponential regression model as a function of body size. Such a population-based mathematical model can provide a comprehensive organ dose estimation given body size and CTDIvol. The model was integrated into an iPhone app XCATdose version 2, enhancing the 1st version based upon fixed tube current modulation. With the organ dose calculator, physicists, physicians, and patients can conveniently estimate organ dose.

  18. A Methodology to Compare Insulin Dosing Recommendations in Real-Life Settings.

    PubMed

    Groat, Danielle; Grando, Maria A; Thompson, Bithika; Neto, Pedro; Soni, Hiral; Boyle, Mary E; Bailey, Marilyn; Cook, Curtiss B

    2017-11-01

    We propose a methodology to analyze complex real-life glucose data in insulin pump users. Patients with type 1 diabetes (T1D) on insulin pumps were recruited from an academic endocrinology practice. Glucose data, insulin bolus (IB) amounts, and self-reported alcohol consumption and exercise events were collected for 30 days. Rules were developed to retrospectively compare IB recommendations from the insulin pump bolus calculator (IPBC) against recommendations from a proposed decision aid (PDA) and for assessing the PDA's recommendation for exercise and alcohol. Data from 15 participants were analyzed. When considering instances where glucose was below target, the PDA recommended a smaller dose in 14%, but a larger dose in 13% and an equivalent IB in 73%. For glucose levels at target, the PDA suggested an equivalent IB in 58% compared to the subject's IPBC, but higher doses in 20% and lower in 22%. In events where postprandial glucose was higher than target, the PDA suggested higher doses in 25%, lower doses in 13%, and equivalent doses in 62%. In 64% of all alcohol events the PDA would have provided appropriate advice. In 75% of exercise events, the PDA appropriately advised an IB, a carbohydrate snack, or neither. This study provides a methodology to systematically analyze real-life data generated by insulin pumps and allowed a preliminary analysis of the performance of the PDA for insulin dosing. Further testing of the methodological approach in a broader diabetes population and prospective testing of the PDA are needed.

  19. Quantification of applied dose in irradiated citrus fruits by DNA Comet Assay together with image analysis.

    PubMed

    Cetinkaya, Nurcan; Ercin, Demet; Özvatan, Sümer; Erel, Yakup

    2016-02-01

    The experiments were conducted for quantification of applied dose for quarantine control in irradiated citrus fruits. Citrus fruits exposed to doses of 0.1 to 1.5 kGy and analyzed by DNA Comet Assay. Observed comets were evaluated by image analysis. The tail length, tail moment and tail DNA% of comets were used for the interpretation of comets. Irradiated citrus fruits showed the separated tails from the head of the comet by increasing applied doses from 0.1 to 1.5 kGy. The mean tail length and mean tail moment% levels of irradiated citrus fruits at all doses are significantly different (p < 0.01) from control even for the lowest dose at 0.1 kGy. Thus, DNA Comet Assay may be a practical quarantine control method for irradiated citrus fruits since it has been possible to estimate the applied low doses as small as 0.1 kGy when it is combined with image analysis. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Dose to 'water-like' media or dose to tissue in MV photons radiotherapy treatment planning: still a matter of debate.

    PubMed

    Andreo, Pedro

    2015-01-07

    The difference between Monte Carlo Treatment Planning (MCTP) based on the assumption of 'water-like' tissues with densities obtained from CT procedures, or on tissue compositions derived from CT-determined densities, have been investigated. Stopping powers and electron fluences have been calculated for a range of media and body tissues for 6 MV photon beams, including changes in their physical data (density and stopping powers). These quantities have been used to determine absorbed doses using cavity theory. It is emphasized that tissue compositions given in ICRU or ICRP reports should not be given the standing of physical constants as they correspond to average values obtained for a limited number of human-body samples. It has been shown that mass stopping-power ratios to water are more dependent on patient-to-patient composition differences, and therefore on their mean excitation energies (I-values), than on mass density. Electron fluence in different media are also more dependent on media composition (and their I-values) than on density. However, as a consequence of the balance between fluence and stopping powers, doses calculated from their product are more constant than what the independent stopping powers and fluence variations suggest. Additionally, cancelations in dose ratios minimize the differences between the 'water-like' and 'tissue' approaches, yielding practically identical results except for bone, and to a lesser extent for adipose tissue. A priori, changing from one approach to another does not seem to be justified considering the large number of approximations and uncertainties involved throughout the treatment planning tissue segmentation and dose calculation procedures. The key issue continues to be the composition of tissues and their I-values, and as these cannot be obtained for individual patients, whatever approach is selected does not lead to significant differences from a water reference dose, the maximum of these being of the order of 5

  1. "Double-Dosing" in Math in North Carolina Public Schools. REL 2016-140

    ERIC Educational Resources Information Center

    Henry, Gary T.; Barrett, Nathan; Marder, Camille

    2016-01-01

    Double-dosing in math expands the time for students to learn by having them enroll in two (or occasionally more) math courses during the regular school day. Although the practice can take different forms and be used at different grade levels (Chait, Muller, Goldware, & Housman, 2007; Nomi & Allensworth, 2009), most research on…

  2. An automated dose tracking system for adaptive radiation therapy.

    PubMed

    Liu, Chang; Kim, Jinkoo; Kumarasiri, Akila; Mayyas, Essa; Brown, Stephen L; Wen, Ning; Siddiqui, Farzan; Chetty, Indrin J

    2018-02-01

    The implementation of adaptive radiation therapy (ART) into routine clinical practice is technically challenging and requires significant resources to perform and validate each process step. The objective of this report is to identify the key components of ART, to illustrate how a specific automated procedure improves efficiency, and to facilitate the routine clinical application of ART. Data was used from patient images, exported from a clinical database and converted to an intermediate format for point-wise dose tracking and accumulation. The process was automated using in-house developed software containing three modularized components: an ART engine, user interactive tools, and integration tools. The ART engine conducts computing tasks using the following modules: data importing, image pre-processing, dose mapping, dose accumulation, and reporting. In addition, custom graphical user interfaces (GUIs) were developed to allow user interaction with select processes such as deformable image registration (DIR). A commercial scripting application programming interface was used to incorporate automated dose calculation for application in routine treatment planning. Each module was considered an independent program, written in C++or C#, running in a distributed Windows environment, scheduled and monitored by integration tools. The automated tracking system was retrospectively evaluated for 20 patients with prostate cancer and 96 patients with head and neck cancer, under institutional review board (IRB) approval. In addition, the system was evaluated prospectively using 4 patients with head and neck cancer. Altogether 780 prostate dose fractions and 2586 head and neck cancer dose fractions went processed, including DIR and dose mapping. On average, daily cumulative dose was computed in 3 h and the manual work was limited to 13 min per case with approximately 10% of cases requiring an additional 10 min for image registration refinement. An efficient and convenient

  3. Translating reference doses into allergen management practice: challenges for stakeholders.

    PubMed

    Crevel, René W R; Baumert, Joseph L; Luccioli, Stefano; Baka, Athanasia; Hattersley, Sue; Hourihane, Jonathan O'B; Ronsmans, Stefan; Timmermans, Frans; Ward, Rachel; Chung, Yong-joo

    2014-05-01

    Risk assessment describes the impact of a particular hazard as a function of dose and exposure. It forms the foundation of risk management and contributes to the overall decision-making process, but is not its endpoint. This paper outlines a risk analysis framework to underpin decision-making in the area of allergen cross-contact. Specifically, it identifies challenges relevant to each component of the risk analysis: risk assessment (data gaps and output interpretation); risk management (clear and realistic objectives); and risk communication (clear articulation of risk and benefit). Translation of the outputs from risk assessment models into risk management measures must be informed by a clear understanding of the model outputs and their limitations. This will lead to feasible and achievable risk management objectives, grounded in a level of risk accepted by the different stakeholders, thereby avoiding potential unintended detrimental consequences. Clear, consistent and trustworthy communications actively involving all stakeholders underpin these objectives. The conclusions, integrating the perspectives of different stakeholders, offer a vision where clear, science-based benchmarks form the basis of allergen management and labelling, cutting through the current confusion and uncertainty. Finally, the paper recognises that the proposed framework must be adaptable to new and emerging evidence. Copyright © 2014 ILSI Europe. Published by Elsevier Ltd.. All rights reserved.

  4. The Acute Gastrointestinal Syndrome in High-Dose Irradiated Mice

    PubMed Central

    Booth, Catherine; Tudor, Gregory; Tudor, Julie; Katz, Barry P; MacVittie, Thomas

    2012-01-01

    The most detailed reports of the response of the gastrointestinal system to high dose acute radiation have focused mainly on understanding the histopathology. However, to enable medical countermeasure assessment under the animal rule criteria, it is necessary to have a robust model in which the relationship between radiation dose and intestinal radiation syndrome incidence, timing and severity are established and correlated with histopathology. Although many mortality studies have been published, they have used a variety of mouse strains, ages, radiation sources and husbandry conditions, all of which influence the dose response. Further, it is clear that the level of bone marrow irradiation and supportive care can influence endpoints. In order to create robust baseline data we have generated dose response data in adult male mice, maintained under identical conditions, and exposed to either total or partial-body irradiation. Partial-body irradiation includes both extensive (40%) and minimal (5%) bone marrow sparing models, the latter designed to correlate with an established primate model and allow assessment of effects of any medical countermeasure on all three major radiation syndromes (intestinal, bone marrow and lung) in the surviving mice. Lethal dose (LD30, LD50 and LD70) data are described in the various models, along with the impact of enteric flora and response to supportive care. Correlation with diarrhea severity and histopathology are also described. This data can be used to aid the design of good laboratory practice (GLP) compliant Animal Rule studies that are reflective of the conditions following accidental radiation exposure. PMID:23091876

  5. SU-G-201-17: Verification of Dose Distributions From High-Dose-Rate Brachytherapy Ir-192 Source Using a Multiple-Array-Diode-Detector (MapCheck2)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harpool, K; De La Fuente Herman, T; Ahmad, S

    be improved when considering medium heterogeneity and dose-artifact of the diodes. This study demonstrates that multiple-array-diode-detectors provide practical and accurate dosimeter to verify doses delivered from the brachytherapy Ir-192-source.« less

  6. Colon cleansing protocol in children: research conditions vs. clinical practice.

    PubMed

    Elitsur, Yoram; Balfaqih, Yaslam; Preston, Deborah

    2018-04-01

     Colon preparation rates are the limiting factor for a successful diagnostic colonoscopy in children. Different colon cleansing protocols have been published for use in children. Unfortunately, the applicability of those published research protocols has not been formally evaluated in routine clinical practice. We investigated the success rate of our previously published colon cleansing protocol as utilized in our clinical practice.  This was a retrospective study. In the clinical practice, the colon cleansing protocol included PEG-3350 at a dose of 2 g/kg/day plus Dulcolax (Bisacodyl, Boehringer Ingelheim, TX USA) 5 mg/day for 2 days. Adequate colon preparation was graded between 1 - 5, as previously described, and grade ≥ 4.0 was considered an adequate preparation. Patients were instructed to complete a questionnaire that included PEG-3350 dose, number of stools per day, consistency of each stool, and side effects (vomiting, abdominal pain). Clinical and endoscopic results were compared between the protocol under research conditions and routine practice.  The success rate of the colon preparation in our clinical practice was similar to the results observed under our research protocol (75 % vs. 73.6 %). Moreover, the total number of stools, stool consistency, and the intubation rate of the terminal ileum were also similar. We concluded, that in our experience, the colon cleansing protocol used under research conditions was effective and appropriate for use in routine clinical practice.  We recommend testing each new protocol under the routine conditions of clinical practice to confirm its applicability for general practitioners.

  7. Hybrid dose calculation: a dose calculation algorithm for microbeam radiation therapy

    NASA Astrophysics Data System (ADS)

    Donzelli, Mattia; Bräuer-Krisch, Elke; Oelfke, Uwe; Wilkens, Jan J.; Bartzsch, Stefan

    2018-02-01

    Microbeam radiation therapy (MRT) is still a preclinical approach in radiation oncology that uses planar micrometre wide beamlets with extremely high peak doses, separated by a few hundred micrometre wide low dose regions. Abundant preclinical evidence demonstrates that MRT spares normal tissue more effectively than conventional radiation therapy, at equivalent tumour control. In order to launch first clinical trials, accurate and efficient dose calculation methods are an inevitable prerequisite. In this work a hybrid dose calculation approach is presented that is based on a combination of Monte Carlo and kernel based dose calculation. In various examples the performance of the algorithm is compared to purely Monte Carlo and purely kernel based dose calculations. The accuracy of the developed algorithm is comparable to conventional pure Monte Carlo calculations. In particular for inhomogeneous materials the hybrid dose calculation algorithm out-performs purely convolution based dose calculation approaches. It is demonstrated that the hybrid algorithm can efficiently calculate even complicated pencil beam and cross firing beam geometries. The required calculation times are substantially lower than for pure Monte Carlo calculations.

  8. Moving toward uniform and evidence-based practice of radiotherapy for management of cervical cancer in Ontario, Canada.

    PubMed

    Shahid, Negin; Craig, Timothy; Westerland, Mary; Ashworth, Allison; Ang, Michelle; D'Souza, David; Sankreacha, Raxa; Fyles, Anthony; Milosevic, Michael; Kong, Iwa

    2018-04-19

    To recognize the practice of radiotherapy for management of cervical cancer in Ontario, Canada, and to use the results of the survey to harmonize and standardize practice across the province. An electronic survey (SurveyMonkey) was sent to all 14 provincial cancer centers by Cancer Care Ontario Gynecology Community of Practice (CoP) in 2013. The survey included 72 questions in four different categories: general/demographic, pretreatment assessment, external beam radiotherapy (EBRT), and brachytherapy (BT). Ten of 14 centers treated cervical cancer patients and had a dedicated BT suite. All 10 centers had a peer review process for quality assurance. EBRT technique was a 4-field box in eight of 10 centers. The dose/fractionation for pelvic EBRT was 45-50 Gy in 1.8-2 Gy/fraction in all but one center. Nine of 10 centers used high-dose-rate BT. Only one center offered interstitial BT. For treatment planning, two centers used CT and MRI, five centers used CT, and three centers used orthogonal x-rays. Groupe Européen de Curiethérapie and the European Society for Radiotherapy & Oncology guidelines were used in four of seven of the centers for target volume delineation and in five of seven centers for organs at risk dose constraints. All but one center prescribed and reported dose to Point A. The survey identified areas where practice varied across the province. Gynecology CoP used this information to identify priorities for practice change and implemented several strategies to harmonize the care of women with cervical cancer. This highlights the value of interdisciplinary, grass-roots initiatives such as CoPs to standardize practice in a practical manner that directly benefits patients. Copyright © 2018 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  9. The energy dependence of the lateral dose response functions of detectors with various densities in photon-beam dosimetry.

    PubMed

    Looe, Hui Khee; Harder, Dietrich; Poppe, Björn

    2017-02-07

    The lateral dose response function is a general characteristic of the volume effect of a detector used for photon dosimetry in a water phantom. It serves as the convolution kernel transforming the true absorbed dose to water profile, which would be produced within the undisturbed water phantom, into the detector-measured signal profile. The shape of the lateral dose response function characterizes (i) the volume averaging attributable to the detector's size and (ii) the disturbance of the secondary electron field associated with the deviation of the electron density of the detector material from the surrounding water. In previous work, the characteristic dependence of the shape of the lateral dose response function upon the electron density of the detector material was studied for 6 MV photons by Monte Carlo simulation of a wall-less voxel-sized detector (Looe et al 2015 Phys. Med. Biol. 60 6585-07). This study is here continued for 60 Co gamma rays and 15 MV photons in comparison with 6 MV photons. It is found (1) that throughout these photon spectra the shapes of the lateral dose response functions are retaining their characteristic dependence on the detector's electron density, and (2) that their energy-dependent changes are only moderate. This appears as a practical advantage because the lateral dose response function can then be treated as practically invariant across a clinical photon beam in spite of the known changes of the photon spectrum with increasing distance from the beam axis.

  10. Variable beam dose rate and DMLC IMRT to moving body anatomy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Papiez, Lech; Abolfath, Ramin M.

    2008-11-15

    Derivation of formulas relating leaf speeds and beam dose rates for delivering planned intensity profiles to static and moving targets in dynamic multileaf collimator (DMLC) intensity modulated radiation therapy (IMRT) is presented. The analysis of equations determining algorithms for DMLC IMRT delivery under a variable beam dose rate reveals a multitude of possible delivery strategies for a given intensity map and for any given target motion patterns. From among all equivalent delivery strategies for DMLC IMRT treatments specific subclasses of strategies can be selected to provide deliveries that are particularly suitable for clinical applications providing existing delivery devices are used.more » Special attention is devoted to the subclass of beam dose rate variable DMLC delivery strategies to moving body anatomy that generalize existing techniques of such deliveries in Varian DMLC irradiation methodology to static body anatomy. Few examples of deliveries from this subclass of DMLC IMRT irradiations are investigated to illustrate the principle and show practical benefits of proposed techniques.« less

  11. Single dose sublingual testosterone and oral sildenafil vs. a dual route/dual release fixed dose combination tablet: a pharmacokinetic comparison

    PubMed Central

    van Rooij, Kim; de Leede, Leo; Frijlink, Henderik W.; Koppeschaar, Hans P. F.; Olivier, Berend; Tuiten, Adriaan

    2016-01-01

    Aim The aim was to compare the pharmacokinetic profiles of two formulations of a combination drug product containing 0.5 mg testosterone and 50 mg sildenafil for female sexual interest/arousal disorder. The prototype (formulation 1) consists of a testosterone solution for sublingual administration and a sildenafil tablet that is administered 2.5 h later. The dual route/dual release fixed dose combination tablet (formulation 2) employs a sublingual and an oral route for systemic uptake. This tablet has an inner core of sildenafil with a polymeric time delay coating and an outer polymeric coating containing testosterone. It was designed to increase dosing practicality and decrease potential temporal non‐adherence through circumventing the relatively complex temporal dosing scheme. Methods Twelve healthy premenopausal subjects received both formulations randomly on separate days. Blood was sampled frequently to determine the pharmacokinetics of free testosterone, total testosterone, dihydrotestosterone, sildenafil and N‐desmethyl‐sildenafil. Results Formulation 2 had a higher maximum concentration (C max) for testosterone, 8.06 ng ml–1 (95% confidence interval [CI] 6.84, 9.28) and higher area under the plasma concentration–time curve (AUC), 7.69 ng ml–1 h (95% CI 6.22, 9.16) than formulation 1, 5.66 ng ml–1 (95% CI 4.63, 6.69) and 5.12 ng ml–1 h (95% CI 4.51, 5.73), respectively. Formulation 2 had a lower C max for sildenafil, 173 ng ml–1 (95% CI 126, 220) and a lower AUC, 476 ng ml–1 h (95% CI 401, 551) than formulation 1, 268 ng ml–1 (95% CI 188, 348) and 577 ng ml–1 h (95% CI 462, 692), respectively. Formulation 2 released sildenafil after 2.75 h (95% CI 2.40, 3.10). Conclusions The dual route/dual release fixed dose combination tablet fulfilled its design criteria and is considered suitable for further clinical testing. What is Already Known about this Subject Female sexual interest/arousal disorder (FSIAD) is a

  12. Insights into implementation of sacubitril/valsartan into clinical practice.

    PubMed

    Martens, Pieter; Beliën, Hanne; Dupont, Matthias; Mullens, Wilfried

    2018-06-01

    Sacubitril/valsartan significantly reduced heart failure hospitalization and mortality in PARADIGM-HF (Prospective Comparison of Angiotensin Receptor-Neprilysin Inhibitor With an Angiotensin-Converting Enzyme Inhibitor to Determine Impact on Global Mortality and Morbidity in Heart Failure). However, real-world data from its use are lacking. We retrospectively assessed all baseline and follow-up data of consecutive heart failure patients with reduced ejection fraction receiving therapy with sacubitril/valsartan for Class I recommendation between December 2016 and July 2017. Baseline characteristics and dose titration of sacubitril/valsartan were compared between patients in clinical practice and in PARADIGM-HF. A total of 120 patients (81% male) were switched from angiotensin-converting enzyme inhibitor or angiotensin receptor blocker to sacubitril/valsartan. A total of 20.1% of patients received dose uptitration. Patients were treated with an equipotential dose of renin-angiotensin system blockers before and after uptitration of sacubitril/valsartan (57 ± 29% vs. 53 ± 29% of target dose indicated by European Society of Cardiology guidelines; P = 0.286). However, they received a lower dose of sacubitril/valsartan in comparison with those in the PARADIGM-HF (219 ± 12 vs. 375 ± 75 mg; P < 0.001). In comparison with the patients receiving sacubitril/valsartan in PARADIGM-HF, patients in clinical practice were older and had a higher serum creatinine, higher New York Heart Association functional classification, and lower left ventricular ejection fraction (all P-value <0.05). Even in comparison with patients who experienced dropout during the run-in phase of PARADIGM-HF, real-world patients exhibited baseline characteristics indicative of more disease severity. Patients were at high absolute baseline risk for adverse outcome as illustrated by the EMPHASIS-HF (Eplerenone in Mild Patients Hospitalization and Survival Study in Heart Failure) risk score of 6

  13. Sensitivity and specificity of dosing alerts for dosing errors among hospitalized pediatric patients

    PubMed Central

    Stultz, Jeremy S; Porter, Kyle; Nahata, Milap C

    2014-01-01

    Objectives To determine the sensitivity and specificity of a dosing alert system for dosing errors and to compare the sensitivity of a proprietary system with and without institutional customization at a pediatric hospital. Methods A retrospective analysis of medication orders, orders causing dosing alerts, reported adverse drug events, and dosing errors during July, 2011 was conducted. Dosing errors with and without alerts were identified and the sensitivity of the system with and without customization was compared. Results There were 47 181 inpatient pediatric orders during the studied period; 257 dosing errors were identified (0.54%). The sensitivity of the system for identifying dosing errors was 54.1% (95% CI 47.8% to 60.3%) if customization had not occurred and increased to 60.3% (CI 54.0% to 66.3%) with customization (p=0.02). The sensitivity of the system for underdoses was 49.6% without customization and 60.3% with customization (p=0.01). Specificity of the customized system for dosing errors was 96.2% (CI 96.0% to 96.3%) with a positive predictive value of 8.0% (CI 6.8% to 9.3). All dosing errors had an alert over-ridden by the prescriber and 40.6% of dosing errors with alerts were administered to the patient. The lack of indication-specific dose ranges was the most common reason why an alert did not occur for a dosing error. Discussion Advances in dosing alert systems should aim to improve the sensitivity and positive predictive value of the system for dosing errors. Conclusions The dosing alert system had a low sensitivity and positive predictive value for dosing errors, but might have prevented dosing errors from reaching patients. Customization increased the sensitivity of the system for dosing errors. PMID:24496386

  14. Low-Dose versus Standard-Dose Intravenous Alteplase in Acute Ischemic Stroke.

    PubMed

    Anderson, Craig S; Robinson, Thompson; Lindley, Richard I; Arima, Hisatomi; Lavados, Pablo M; Lee, Tsong-Hai; Broderick, Joseph P; Chen, Xiaoying; Chen, Guofang; Sharma, Vijay K; Kim, Jong S; Thang, Nguyen H; Cao, Yongjun; Parsons, Mark W; Levi, Christopher; Huang, Yining; Olavarría, Verónica V; Demchuk, Andrew M; Bath, Philip M; Donnan, Geoffrey A; Martins, Sheila; Pontes-Neto, Octavio M; Silva, Federico; Ricci, Stefano; Roffe, Christine; Pandian, Jeyaraj; Billot, Laurent; Woodward, Mark; Li, Qiang; Wang, Xia; Wang, Jiguang; Chalmers, John

    2016-06-16

    Thrombolytic therapy for acute ischemic stroke with a lower-than-standard dose of intravenous alteplase may improve recovery along with a reduced risk of intracerebral hemorrhage. Using a 2-by-2 quasi-factorial open-label design, we randomly assigned 3310 patients who were eligible for thrombolytic therapy (median age, 67 years; 63% Asian) to low-dose intravenous alteplase (0.6 mg per kilogram of body weight) or the standard dose (0.9 mg per kilogram); patients underwent randomization within 4.5 hours after the onset of stroke. The primary objective was to determine whether the low dose would be noninferior to the standard dose with respect to the primary outcome of death or disability at 90 days, which was defined by scores of 2 to 6 on the modified Rankin scale (range, 0 [no symptoms] to 6 [death]). Secondary objectives were to determine whether the low dose would be superior to the standard dose with respect to centrally adjudicated symptomatic intracerebral hemorrhage and whether the low dose would be noninferior in an ordinal analysis of modified Rankin scale scores (testing for an improvement in the distribution of scores). The trial included 935 patients who were also randomly assigned to intensive or guideline-recommended blood-pressure control. The primary outcome occurred in 855 of 1607 participants (53.2%) in the low-dose group and in 817 of 1599 participants (51.1%) in the standard-dose group (odds ratio, 1.09; 95% confidence interval [CI], 0.95 to 1.25; the upper boundary exceeded the noninferiority margin of 1.14; P=0.51 for noninferiority). Low-dose alteplase was noninferior in the ordinal analysis of modified Rankin scale scores (unadjusted common odds ratio, 1.00; 95% CI, 0.89 to 1.13; P=0.04 for noninferiority). Major symptomatic intracerebral hemorrhage occurred in 1.0% of the participants in the low-dose group and in 2.1% of the participants in the standard-dose group (P=0.01); fatal events occurred within 7 days in 0.5% and 1.5%, respectively

  15. Evaluation of radiation dose to anthropomorphic paediatric models from positron-emitting labelled tracers

    NASA Astrophysics Data System (ADS)

    Xie, Tianwu; Zaidi, Habib

    2014-03-01

    PET uses specific molecules labelled with positron-emitting radionuclides to provide valuable biochemical and physiological information. However, the administration of radiotracers to patients exposes them to low-dose ionizing radiation, which is a concern in the paediatric population since children are at a higher cancer risk from radiation exposure than adults. Therefore, radiation dosimety calculations for commonly used positron-emitting radiotracers in the paediatric population are highly desired. We evaluate the absorbed dose and effective dose for 19 positron-emitting labelled radiotracers in anthropomorphic paediatric models including the newborn, 1-, 5-, 10- and 15-year-old male and female. This is achieved using pre-calculated S-values of positron-emitting radionuclides of UF-NCI paediatric phantoms and published biokinetic data for various radiotracers. The influence of the type of anthropomorphic model, tissue weight factors and direct human- versus mouse-derived biokinetic data on the effective dose for paediatric phantoms was also evaluated. In the case of 18F-FDG, dosimetry calculations of reference paediatric patients from various dose regimens were also calculated. Among the considered radiotracers, 18F-FBPA and 15O-water resulted in the highest and lowest effective dose in the paediatric phantoms, respectively. The ICRP 103 updated tissue-weighting factors decrease the effective dose in most cases. Substantial differences of radiation dose were observed between direct human- versus mouse-derived biokinetic data. Moreover, the effect of using voxel- versus MIRD-type models on the calculation of the effective dose was also studied. The generated database of absorbed organ dose and effective dose for various positron-emitting labelled radiotracers using new generation computational models and the new ICRP tissue-weighting factors can be used for the assessment of radiation risks to paediatric patients in clinical practice. This work also contributes

  16. Task related doses in Spanish pressurized water reactors over the period 1988-1992

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    O`Donnell, P.; Labarta, T.; Amor, I.

    1995-03-01

    In order to evaluate in depth the collective dose trend and its correlation with the effectiveness of the practical application of the ALARA principle in Spanish nuclear facilities, and base the different policy lines to promote this criteria, the CSN has fullfilled an analysis of the task related doses data over the period 1988-1992. Previously, the CSN had required to the utilities the compilation of their refuelling outage collective dose from 1988 according with a predeterminate number of tasks, in order to have available a representative and retrospective set of data in an homogeneous way and coherent with the internationalmore » data banks on occupational exposure in NPP, as the CEC and the NEA ones. The scope of this analysis was the following: first, the collective dose summaries for outage tasks and departments for PWR and for BWR, including the minimum, maximum and average dose (and statistics data) for 18 different refuelling outage tasks and 12 personal departments for each generation of each type of rector, the task and department related collective dose trends in each plant and in each generation, and second, the dose reduction techniques having been used during that period in each plant and the relative level of adoption. In this presentation the main results and conclusions of the first part of the study are reviewed for PWR.« less

  17. Magnetization transfer proportion: a simplified measure of dose response for polymer gel dosimetry.

    PubMed

    Whitney, Heather M; Gochberg, Daniel F; Gore, John C

    2008-12-21

    The response to radiation of polymer gel dosimeters has most often been described by measuring the nuclear magnetic resonance transverse relaxation rate as a function of dose. This approach is highly dependent upon the choice of experimental parameters, such as the echo spacing time for Carr-Purcell-Meiboom-Gill-type pulse sequences, and is difficult to optimize in imaging applications where a range of doses are applied to a single gel, as is typical for practical uses of polymer gel dosimetry. Moreover, errors in computing dose can arise when there are substantial variations in the radiofrequency (B1) field or resonant frequency, as may occur for large samples. Here we consider the advantages of using magnetization transfer imaging as an alternative approach and propose the use of a simplified quantity, the magnetization transfer proportion (MTP), to assess doses. This measure can be estimated through two simple acquisitions and is more robust in the presence of some sources of system imperfections. It also has a dependence upon experimental parameters that is independent of dose, allowing simultaneous optimization at all dose levels. The MTP is shown to be less susceptible to B1 errors than are CPMG measurements of R2. The dose response can be optimized through appropriate choices of the power and offset frequency of the pulses used in magnetization transfer imaging.

  18. SU-E-T-184: Clinical VMAT QA Practice Using LINAC Delivery Log Files

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnston, H; Jacobson, T; Gu, X

    2015-06-15

    Purpose: To evaluate the accuracy of volumetric modulated arc therapy (VMAT) treatment delivery dose clouds by comparing linac log data to doses measured using an ionization chamber and film. Methods: A commercial IMRT quality assurance (QA) process utilizing a DICOM-RT framework was tested for clinical practice using 30 prostate and 30 head and neck VMAT plans. Delivered 3D VMAT dose distributions were independently checked using a PinPoint ionization chamber and radiographic film in a solid water phantom. DICOM RT coordinates were used to extract the corresponding point and planar doses from 3D log file dose distributions. Point doses were evaluatedmore » by computing the percent error between log file and chamber measured values. A planar dose evaluation was performed for each plan using a 2D gamma analysis with 3% global dose difference and 3 mm isodose point distance criteria. The same analysis was performed to compare treatment planning system (TPS) doses to measured values to establish a baseline assessment of agreement. Results: The mean percent error between log file and ionization chamber dose was 1.0%±2.1% for prostate VMAT plans and −0.2%±1.4% for head and neck plans. The corresponding TPS calculated and measured ionization chamber values agree within 1.7%±1.6%. The average 2D gamma passing rates for the log file comparison to film are 98.8%±1.0% and 96.2%±4.2% for the prostate and head and neck plans, respectively. The corresponding passing rates for the TPS comparison to film are 99.4%±0.5% and 93.9%±5.1%. Overall, the point dose and film data indicate that log file determined doses are in excellent agreement with measured values. Conclusion: Clinical VMAT QA practice using LINAC treatment log files is a fast and reliable method for patient-specific plan evaluation.« less

  19. Predicting Maintenance Doses of Vancomycin for Hospitalized Patients Undergoing Hemodialysis.

    PubMed

    El Nekidy, Wasim S; El-Masri, Maher M; Umstead, Greg S; Dehoorne-Smith, Michelle

    2016-01-01

    Methicillin-resistant Staphylococcus aureus is a leading cause of death in patients undergoing hemodialysis. However, controversy exists about the optimal dose of vancomycin that will yield the recommended pre-hemodialysis serum concentration of 15-20 mg/L. To develop a data-driven model to optimize the accuracy of maintenance dosing of vancomycin for patients undergoing hemodialysis. A prospective observational cohort study was performed with 164 observations obtained from a convenience sample of 63 patients undergoing hemodialysis. All vancomycin doses were given on the floor after completion of a hemodialysis session. Multivariate linear generalized estimating equation analysis was used to examine independent predictors of pre-hemodialysis serum vancomycin concentration. Pre-hemodialysis serum vancomycin concentration was independently associated with maintenance dose ( B = 0.658, p < 0.001), baseline pre-hemodialysis serum concentration of the drug ( B = 0.492, p < 0.001), and interdialytic interval ( B = -2.133, p < 0.001). According to the best of 4 models that were developed, the maintenance dose of vancomycin required to achieve a pre-hemodialysis serum concentration of 15-20 mg/L, if the baseline serum concentration of the drug was also 15-20 mg/L, was 5.9 mg/kg with interdialytic interval of 48 h and 7.1 mg/kg with interdialytic interval of 72 h. However, if the baseline pre-hemodialysis serum concentration was 10-14.99 mg/L, the required dose increased to 9.2 mg/kg with an interdialytic interval of 48 h and 10.0 mg/kg with an interdialytic interval of 72 h. The maintenance dose of vancomycin varied according to baseline pre-hemodialysis serum concentration of the drug and interdialytic interval. The current practice of targeting a pre-hemodialysis concentration of 15-20 mg/L may be difficult to achieve for the majority of patients undergoing hemodialysis.

  20. MIT Lincoln Laboratory Takes the Mystery Out of Supercomupting

    DTIC Science & Technology

    2017-01-18

    analysis, designing sensors, and developing algorithms. In 2008, the Lincoln demonstrated the largest single problem ever run on a computer using ... computation . As we design and prototype these devices, the use of leading–edge engineering practices have become the de facto standard. This includes...MIT Lincoln Laboratory Takes the Mystery Out of Supercomputing By Dr. Jeremy Kepner 1 The introduction of multicore and manycore processors

  1. Effect of High-Dose vs Standard-Dose Wintertime Vitamin D Supplementation on Viral Upper Respiratory Tract Infections in Young Healthy Children.

    PubMed

    Aglipay, Mary; Birken, Catherine S; Parkin, Patricia C; Loeb, Mark B; Thorpe, Kevin; Chen, Yang; Laupacis, Andreas; Mamdani, Muhammad; Macarthur, Colin; Hoch, Jeffrey S; Mazzulli, Tony; Maguire, Jonathon L

    2017-07-18

    Epidemiological studies support a link between low 25-hydroxyvitamin D levels and a higher risk of viral upper respiratory tract infections. However, whether winter supplementation of vitamin D reduces the risk among children is unknown. To determine whether high-dose vs standard-dose vitamin D supplementation reduces the incidence of wintertime upper respiratory tract infections in young children. A randomized clinical trial was conducted during the winter months between September 13, 2011, and June 30, 2015, among children aged 1 through 5 years enrolled in TARGet Kids!, a multisite primary care practice-based research network in Toronto, Ontario, Canada. Three hundred forty-nine participants were randomized to receive 2000 IU/d of vitamin D oral supplementation (high-dose group) vs 354 participants who were randomized to receive 400 IU/d (standard-dose group) for a minimum of 4 months between September and May. The primary outcome was the number of laboratory-confirmed viral upper respiratory tract infections based on parent-collected nasal swabs over the winter months. Secondary outcomes included the number of influenza infections, noninfluenza infections, parent-reported upper respiratory tract illnesses, time to first upper respiratory tract infection, and serum 25-hydroxyvitamin D levels at study termination. Among 703 participants who were randomized (mean age, 2.7 years, 57.7% boys), 699 (99.4%) completed the trial. The mean number of laboratory-confirmed upper respiratory tract infections per child was 1.05 (95% CI, 0.91-1.19) for the high-dose group and 1.03 (95% CI, 0.90-1.16) for the standard-dose group, for a between-group difference of 0.02 (95% CI, -0.17 to 0.21) per child. There was no statistically significant difference in number of laboratory-confirmed infections between groups (incidence rate ratio [RR], 0.97; 95% CI, 0.80-1.16). There was also no significant difference in the median time to the first laboratory-confirmed infection: 3.95 months

  2. Dose control for noncontact laser coagulation of tissue

    NASA Astrophysics Data System (ADS)

    Roggan, Andre; Albrecht, Hansjoerg; Bocher, Thomas; Rygiel, Reiner; Winter, Harald; Mueller, Gerhard J.

    1995-01-01

    Nd:YAG lasers emitting at 1064 nm are often used for coagulation of tissue in a non-contact mode, i.e. the treatment of verrucae, endometriosis, tumor coagulation and hemostasis. During this process an uncontrolled temperature rise of the irradiated area leads to vaporization and, finally, to a carbonization of the tissue surface. To prevent this, a dose controlled system was developed using an on-line regulation of the output laser power. The change of the backscattered intensity (remission) of the primary beam was used as a dose dependent feedback parameter. Its dependence on the temperature was determined with a double integrating sphere system and Monte-Carlo simulations. The remission of the tissue was calculated in slab geometry from diffusion theory and Monte-Carlo simulations. The laser control was realized with a PD-circuit and an A/D-converter, enabling the direct connection to the internal bus of the laser system. Preliminary studies with various tissues revealed the practicability of the system.

  3. Peak skin and eye lens radiation dose from brain perfusion CT based on Monte Carlo simulation.

    PubMed

    Zhang, Di; Cagnon, Chris H; Villablanca, J Pablo; McCollough, Cynthia H; Cody, Dianna D; Stevens, Donna M; Zankl, Maria; Demarco, John J; Turner, Adam C; Khatonabadi, Maryam; McNitt-Gray, Michael F

    2012-02-01

    The purpose of our study was to accurately estimate the radiation dose to skin and the eye lens from clinical CT brain perfusion studies, investigate how well scanner output (expressed as volume CT dose index [CTDI(vol)]) matches these estimated doses, and investigate the efficacy of eye lens dose reduction techniques. Peak skin dose and eye lens dose were estimated using Monte Carlo simulation methods on a voxelized patient model and 64-MDCT scanners from four major manufacturers. A range of clinical protocols was evaluated. CTDI(vol) for each scanner was obtained from the scanner console. Dose reduction to the eye lens was evaluated for various gantry tilt angles as well as scan locations. Peak skin dose and eye lens dose ranged from 81 mGy to 348 mGy, depending on the scanner and protocol used. Peak skin dose and eye lens dose were observed to be 66-79% and 59-63%, respectively, of the CTDI(vol) values reported by the scanners. The eye lens dose was significantly reduced when the eye lenses were not directly irradiated. CTDI(vol) should not be interpreted as patient dose; this study has shown it to overestimate dose to the skin or eye lens. These results may be used to provide more accurate estimates of actual dose to ensure that protocols are operated safely below thresholds. Tilting the gantry or moving the scanning region further away from the eyes are effective for reducing lens dose in clinical practice. These actions should be considered when they are consistent with the clinical task and patient anatomy.

  4. On the impact of improved dosimetric accuracy on head and neck high dose rate brachytherapy.

    PubMed

    Peppa, Vasiliki; Pappas, Eleftherios; Major, Tibor; Takácsi-Nagy, Zoltán; Pantelis, Evaggelos; Papagiannis, Panagiotis

    2016-07-01

    To study the effect of finite patient dimensions and tissue heterogeneities in head and neck high dose rate brachytherapy. The current practice of TG-43 dosimetry was compared to patient specific dosimetry obtained using Monte Carlo simulation for a sample of 22 patient plans. The dose distributions were compared in terms of percentage dose differences as well as differences in dose volume histogram and radiobiological indices for the target and organs at risk (mandible, parotids, skin, and spinal cord). Noticeable percentage differences exist between TG-43 and patient specific dosimetry, mainly at low dose points. Expressed as fractions of the planning aim dose, percentage differences are within 2% with a general TG-43 overestimation except for the spine. These differences are consistent resulting in statistically significant differences of dose volume histogram and radiobiology indices. Absolute differences of these indices are however small to warrant clinical importance in terms of tumor control or complication probabilities. The introduction of dosimetry methods characterized by improved accuracy is a valuable advancement. It does not appear however to influence dose prescription or call for amendment of clinical recommendations for the mobile tongue, base of tongue, and floor of mouth patient cohort of this study. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  5. Case Example of Dose Optimization Using Data From Bortezomib Dose-Finding Clinical Trials

    PubMed Central

    Backenroth, Daniel; Cheung, Ying Kuen Ken; Hershman, Dawn L.; Vulih, Diana; Anderson, Barry; Ivy, Percy; Minasian, Lori

    2016-01-01

    Purpose The current dose-finding methodology for estimating the maximum tolerated dose of investigational anticancer agents is based on the cytotoxic chemotherapy paradigm. Molecularly targeted agents (MTAs) have different toxicity profiles, which may lead to more long-lasting mild or moderate toxicities as well as to late-onset and cumulative toxicities. Several approved MTAs have been poorly tolerated during long-term administration, leading to postmarketing dose optimization studies to re-evaluate the optimal treatment dose. Using data from completed bortezomib dose-finding trials, we explore its toxicity profile, optimize its dose, and examine the appropriateness of current designs for identifying an optimal dose. Patients and Methods We classified the toxicities captured from 481 patients in 14 bortezomib dose-finding studies conducted through the National Cancer Institute Cancer Therapy Evaluation Program, computed the incidence of late-onset toxicities, and compared the incidence of dose-limiting toxicities (DLTs) among groups of patients receiving different doses of bortezomib. Results A total of 13,008 toxicities were captured: 46% of patients’ first DLTs and 88% of dose reductions or discontinuations of treatment because of toxicity were observed after the first cycle. Moreover, for the approved dose of 1.3 mg/m2, the estimated cumulative incidence of DLT was > 50%, and the estimated cumulative incidence of dose reduction or treatment discontinuation because of toxicity was nearly 40%. Conclusions When considering the entire course of treatment, the approved bortezomib dose exceeds the conventional ceiling DLT rate of 20% to 33%. Retrospective analysis of trial data provides an opportunity for dose optimization of MTAs. Future dose-finding studies of MTAs should take into account late-onset toxicities to ensure that a tolerable dose is identified for future efficacy and comparative trials. PMID:26926682

  6. Case Example of Dose Optimization Using Data From Bortezomib Dose-Finding Clinical Trials.

    PubMed

    Lee, Shing M; Backenroth, Daniel; Cheung, Ying Kuen Ken; Hershman, Dawn L; Vulih, Diana; Anderson, Barry; Ivy, Percy; Minasian, Lori

    2016-04-20

    The current dose-finding methodology for estimating the maximum tolerated dose of investigational anticancer agents is based on the cytotoxic chemotherapy paradigm. Molecularly targeted agents (MTAs) have different toxicity profiles, which may lead to more long-lasting mild or moderate toxicities as well as to late-onset and cumulative toxicities. Several approved MTAs have been poorly tolerated during long-term administration, leading to postmarketing dose optimization studies to re-evaluate the optimal treatment dose. Using data from completed bortezomib dose-finding trials, we explore its toxicity profile, optimize its dose, and examine the appropriateness of current designs for identifying an optimal dose. We classified the toxicities captured from 481 patients in 14 bortezomib dose-finding studies conducted through the National Cancer Institute Cancer Therapy Evaluation Program, computed the incidence of late-onset toxicities, and compared the incidence of dose-limiting toxicities (DLTs) among groups of patients receiving different doses of bortezomib. A total of 13,008 toxicities were captured: 46% of patients' first DLTs and 88% of dose reductions or discontinuations of treatment because of toxicity were observed after the first cycle. Moreover, for the approved dose of 1.3 mg/m(2), the estimated cumulative incidence of DLT was > 50%, and the estimated cumulative incidence of dose reduction or treatment discontinuation because of toxicity was nearly 40%. When considering the entire course of treatment, the approved bortezomib dose exceeds the conventional ceiling DLT rate of 20% to 33%. Retrospective analysis of trial data provides an opportunity for dose optimization of MTAs. Future dose-finding studies of MTAs should take into account late-onset toxicities to ensure that a tolerable dose is identified for future efficacy and comparative trials. © 2016 by American Society of Clinical Oncology.

  7. Progressive cone beam CT dose control in image-guided radiation therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yan Hao; Cervino, Laura; Jiang, Steve B.

    2013-06-15

    Purpose: Cone beam CT (CBCT) in image-guided radiotherapy (IGRT) offers a tremendous advantage for treatment guidance. The associated imaging dose is a clinical concern. One unique feature of CBCT-based IGRT is that the same patient is repeatedly scanned during a treatment course, and the contents of CBCT images at different fractions are similar. The authors propose a progressive dose control (PDC) scheme to utilize this temporal correlation for imaging dose reduction. Methods: A dynamic CBCT scan protocol, as opposed to the static one in the current clinical practice, is proposed to gradually reduce the imaging dose in each treatment fraction.more » The CBCT image from each fraction is processed by a prior-image based nonlocal means (PINLM) module to enhance its quality. The increasing amount of prior information from previous CBCT images prevents degradation of image quality due to the reduced imaging dose. Two proof-of-principle experiments have been conducted using measured phantom data and Monte Carlo simulated patient data with deformation. Results: In the measured phantom case, utilizing a prior image acquired at 0.4 mAs, PINLM is able to improve the image quality of a CBCT acquired at 0.2 mAs by reducing the noise level from 34.95 to 12.45 HU. In the synthetic patient case, acceptable image quality is maintained at four consecutive fractions with gradually decreasing exposure levels of 0.4, 0.1, 0.07, and 0.05 mAs. When compared with the standard low-dose protocol of 0.4 mAs for each fraction, an overall imaging dose reduction of more than 60% is achieved. Conclusions: PINLM-PDC is able to reduce CBCT imaging dose in IGRT utilizing the temporal correlations among the sequence of CBCT images while maintaining the quality.« less

  8. SU-E-J-116: Uncertainties Associated with Dose Summation of High-Dose Rate Brachytherapy and Intensity Modulated Radiotherapy for Gynecological Cases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kauweloa, K; Bergamo, A; Gutierrez, A

    Purpose: Determining the cumulative dose distribution (CDD) for gynecological patients treated with both high-dose rate (HDR) brachytherapy and intensity-modulated radiotherapy (IMRT) is challenging. The purpose of this work is to study the uncertainty of performing this with a structure-guided deformable (SGD) approach in Velocity. Methods: For SGD, the Hounsfield units inside specified contours are overridden to set uniform values. Deformable image registration (DIR) is the run on these process images, which forces the DIR to focus on these contour boundaries. 18 gynecological cancer patients were used in this study. The original bladder and rectum planning contours for these patients weremore » used to drive the SGD. A second set of contours were made of the bladder by the same person with the intent of carefully making them completely consistent with each other. This second set was utilized to evaluate the spatial accuracy of the SGD. The determined spatial accuracy was then multiplied by the local dose gradient to determine a dose uncertainty associated with the SGD dose warping. The normal tissue complication probability (NTCP) was then calculated for each dose volume histogram (DVH) that included four different probabilistic uncertainties associated with the spatial errors (e.g., 68.3% and 95.4%). Results: The NTCPs for each DVH (e.g., NTCP-−95.4%, NTCP-−68.3%, NTCP-68.3%, NTCP-95.4%) differed amongst patients. All patients had an NTCP-−95.4% close to 0%, while NTCP-95.4% ranged from 0.67% to 100%. Nine patients had an NTCP-−95.4% less than 50% while the remaining nine patients had NTCP-95.4% greater than 50%. Conclusion: The uncertainty associated with this CDD technique renders a large NTCP uncertainty. Thus, it is currently not practical for clinical use. The two ways to improve this would be to use more precise contours to drive the SGD and to use a more accurate DIR algorithm.« less

  9. Pediatric chest and abdominopelvic CT: organ dose estimation based on 42 patient models.

    PubMed

    Tian, Xiaoyu; Li, Xiang; Segars, W Paul; Paulson, Erik K; Frush, Donald P; Samei, Ehsan

    2014-02-01

    To estimate organ dose from pediatric chest and abdominopelvic computed tomography (CT) examinations and evaluate the dependency of organ dose coefficients on patient size and CT scanner models. The institutional review board approved this HIPAA-compliant study and did not require informed patient consent. A validated Monte Carlo program was used to perform simulations in 42 pediatric patient models (age range, 0-16 years; weight range, 2-80 kg; 24 boys, 18 girls). Multidetector CT scanners were modeled on those from two commercial manufacturers (LightSpeed VCT, GE Healthcare, Waukesha, Wis; SOMATOM Definition Flash, Siemens Healthcare, Forchheim, Germany). Organ doses were estimated for each patient model for routine chest and abdominopelvic examinations and were normalized by volume CT dose index (CTDI(vol)). The relationships between CTDI(vol)-normalized organ dose coefficients and average patient diameters were evaluated across scanner models. For organs within the image coverage, CTDI(vol)-normalized organ dose coefficients largely showed a strong exponential relationship with the average patient diameter (R(2) > 0.9). The average percentage differences between the two scanner models were generally within 10%. For distributed organs and organs on the periphery of or outside the image coverage, the differences were generally larger (average, 3%-32%) mainly because of the effect of overranging. It is feasible to estimate patient-specific organ dose for a given examination with the knowledge of patient size and the CTDI(vol). These CTDI(vol)-normalized organ dose coefficients enable one to readily estimate patient-specific organ dose for pediatric patients in clinical settings. This dose information, and, as appropriate, attendant risk estimations, can provide more substantive information for the individual patient for both clinical and research applications and can yield more expansive information on dose profiles across patient populations within a practice.

  10. Pediatric Chest and Abdominopelvic CT: Organ Dose Estimation Based on 42 Patient Models

    PubMed Central

    Tian, Xiaoyu; Li, Xiang; Segars, W. Paul; Paulson, Erik K.; Frush, Donald P.

    2014-01-01

    Purpose To estimate organ dose from pediatric chest and abdominopelvic computed tomography (CT) examinations and evaluate the dependency of organ dose coefficients on patient size and CT scanner models. Materials and Methods The institutional review board approved this HIPAA–compliant study and did not require informed patient consent. A validated Monte Carlo program was used to perform simulations in 42 pediatric patient models (age range, 0–16 years; weight range, 2–80 kg; 24 boys, 18 girls). Multidetector CT scanners were modeled on those from two commercial manufacturers (LightSpeed VCT, GE Healthcare, Waukesha, Wis; SOMATOM Definition Flash, Siemens Healthcare, Forchheim, Germany). Organ doses were estimated for each patient model for routine chest and abdominopelvic examinations and were normalized by volume CT dose index (CTDIvol). The relationships between CTDIvol-normalized organ dose coefficients and average patient diameters were evaluated across scanner models. Results For organs within the image coverage, CTDIvol-normalized organ dose coefficients largely showed a strong exponential relationship with the average patient diameter (R2 > 0.9). The average percentage differences between the two scanner models were generally within 10%. For distributed organs and organs on the periphery of or outside the image coverage, the differences were generally larger (average, 3%–32%) mainly because of the effect of overranging. Conclusion It is feasible to estimate patient-specific organ dose for a given examination with the knowledge of patient size and the CTDIvol. These CTDIvol-normalized organ dose coefficients enable one to readily estimate patient-specific organ dose for pediatric patients in clinical settings. This dose information, and, as appropriate, attendant risk estimations, can provide more substantive information for the individual patient for both clinical and research applications and can yield more expansive information on dose profiles

  11. Exploring Cultural Predictors of Military Intervention Success

    DTIC Science & Technology

    2015-04-01

    research employed a sequential, mixed method analysis consisting of a quantitative ex post facto analysis of United Nation’s (UN) interventions... research . Results In spite of the many assumptions and limitation forced upon the research by its ex post facto design, it nonetheless provided some... post facto exploration of predictors of military intervention success. As such, the research examined pre- and post -intervention

  12. Seasonal influenza vaccine dose distribution in 157 countries (2004-2011).

    PubMed

    Palache, Abraham; Oriol-Mathieu, Valerie; Abelin, Atika; Music, Tamara

    2014-11-12

    Globally there are an estimated 3-5 million cases of severe influenza illness every year, resulting in 250,000-500,000 deaths. At the World Health Assembly in 2003, World Health Organization (WHO) resolved to increase influenza vaccine coverage rates (VCR) for high-risk groups, particularly focusing on at least 75% of the elderly by 2010. But systematic worldwide data have not been available to assist public health authorities to monitor vaccine uptake and review progress toward vaccination coverage targets. In 2008, the International Federation of Pharmaceutical Manufacturers and Associations Influenza Vaccine Supply task force (IFPMA IVS) developed a survey methodology to assess global influenza vaccine dose distribution. The current survey results represent 2011 data and demonstrate the evolution of the absolute number distributed between 2004 and 2011 inclusive, and the evolution in the per capita doses distributed in 2008-2011. Global distribution of IFPMA IVS member doses increased approximately 86.9% between 2004 and 2011, but only approximately 12.1% between 2008 and 2011. The WHO's regions in Eastern Mediterranean (EMRO), Southeast Asian (SEARO) and Africa (AFRO) together account for about 47% of the global population, but only 3.7% of all IFPMA IVS doses distributed. While distributed doses have globally increased, they have decreased in EURO and EMRO since 2009. Dose distribution can provide a reasonable proxy of vaccine utilization. Based on the dose distribution, we conclude that seasonal influenza VCR in many countries remains well below the WHA's VCR targets and below the recommendations of the Council of the European Union in EURO. Inter- and intra-regional disparities in dose distribution trends call into question the impact of current vaccine recommendations at achieving coverage targets. Additional policy measures, particularly those that influence patients adherence to vaccination programs, such as reimbursement, healthcare provider knowledge

  13. Acceleration of intensity-modulated radiotherapy dose calculation by importance sampling of the calculation matrices.

    PubMed

    Thieke, Christian; Nill, Simeon; Oelfke, Uwe; Bortfeld, Thomas

    2002-05-01

    In inverse planning for intensity-modulated radiotherapy, the dose calculation is a crucial element limiting both the maximum achievable plan quality and the speed of the optimization process. One way to integrate accurate dose calculation algorithms into inverse planning is to precalculate the dose contribution of each beam element to each voxel for unit fluence. These precalculated values are stored in a big dose calculation matrix. Then the dose calculation during the iterative optimization process consists merely of matrix look-up and multiplication with the actual fluence values. However, because the dose calculation matrix can become very large, this ansatz requires a lot of computer memory and is still very time consuming, making it not practical for clinical routine without further modifications. In this work we present a new method to significantly reduce the number of entries in the dose calculation matrix. The method utilizes the fact that a photon pencil beam has a rapid radial dose falloff, and has very small dose values for the most part. In this low-dose part of the pencil beam, the dose contribution to a voxel is only integrated into the dose calculation matrix with a certain probability. Normalization with the reciprocal of this probability preserves the total energy, even though many matrix elements are omitted. Three probability distributions were tested to find the most accurate one for a given memory size. The sampling method is compared with the use of a fully filled matrix and with the well-known method of just cutting off the pencil beam at a certain lateral distance. A clinical example of a head and neck case is presented. It turns out that a sampled dose calculation matrix with only 1/3 of the entries of the fully filled matrix does not sacrifice the quality of the resulting plans, whereby the cutoff method results in a suboptimal treatment plan.

  14. Analysis of uncertainties in Monte Carlo simulated organ dose for chest CT

    NASA Astrophysics Data System (ADS)

    Muryn, John S.; Morgan, Ashraf G.; Segars, W. P.; Liptak, Chris L.; Dong, Frank F.; Primak, Andrew N.; Li, Xiang

    2015-03-01

    In Monte Carlo simulation of organ dose for a chest CT scan, many input parameters are required (e.g., half-value layer of the x-ray energy spectrum, effective beam width, and anatomical coverage of the scan). The input parameter values are provided by the manufacturer, measured experimentally, or determined based on typical clinical practices. The goal of this study was to assess the uncertainties in Monte Carlo simulated organ dose as a result of using input parameter values that deviate from the truth (clinical reality). Organ dose from a chest CT scan was simulated for a standard-size female phantom using a set of reference input parameter values (treated as the truth). To emulate the situation in which the input parameter values used by the researcher may deviate from the truth, additional simulations were performed in which errors were purposefully introduced into the input parameter values, the effects of which on organ dose per CTDIvol were analyzed. Our study showed that when errors in half value layer were within ± 0.5 mm Al, the errors in organ dose per CTDIvol were less than 6%. Errors in effective beam width of up to 3 mm had negligible effect (< 2.5%) on organ dose. In contrast, when the assumed anatomical center of the patient deviated from the true anatomical center by 5 cm, organ dose errors of up to 20% were introduced. Lastly, when the assumed extra scan length was longer by 4 cm than the true value, dose errors of up to 160% were found. The results answer the important question: to what level of accuracy each input parameter needs to be determined in order to obtain accurate organ dose results.

  15. WE-G-BRE-03: Dose Painting by Numbers Using Targeted Gold Nanoparticles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Altundal, Y; Sajo, E; Korideck, H

    Purpose: Homogeneous dose enhancement in tumor cells of lung cancer patients treated with conventional dose of 60–66 Gy in five fractions is limited due to increased risk of toxicity to normal structures. Dose painting by numbers (DPBN) is the prescription of a non-uniform radiation dose distribution in the tumor for each voxel based on the intensity level of that voxel obtained from the tumor image. The purpose of this study is to show that DPBN using targeted gold nanoparticles (GNPs) could enhance conventional doses in the more resistant tumor areas. Methods: Cone beam computed tomography (CBCT) images of GNPs aftermore » intratumoral injection into human tumor were taken at 0, 48, 144 and 160 hours. The dose enhancement in the tumor voxels by secondary electrons from the GNPs was calculated based on analytical microdosimetry methods. The dose enhancement factor (DEF) is the ratio of the doses to the tumor with and without the presence of GNPs. The DEF was calculated for each voxel of the images based on the GNP concentration in the tumor sub-volumes using 6-MV photon spectra obtained using Monte Carlo simulations at 5 cm depth (10×10 cm2 field). Results: The results revealed DEF values of 1.05–2.38 for GNPs concentrations of 1–30 mg/g which corresponds to 12.60 – 28.56 Gy per fraction for delivering 12 Gy per fraction homogenously to lung tumor region. Conclusion: Our preliminary results verify that DPBN could be achieved using GNPs to enhance conventional doses to high risk tumor sub-volumes. In practice, DPBN using GNPs could be achieved due to diffusion of targeted GNPs sustainably released in-situ from radiotherapy biomaterials (e.g. fiducials) coated with polymer film containing the GNPs.« less

  16. Simulation center training as a means to improve resident performance in percutaneous noncontinuous CT-guided fluoroscopic procedures with dose reduction.

    PubMed

    Mendiratta-Lala, Mishal; Williams, Todd R; Mendiratta, Vivek; Ahmed, Hafeez; Bonnett, John W

    2015-04-01

    The purpose of this study was to evaluate the effectiveness of a multifaceted simulation-based resident training for CT-guided fluoroscopic procedures by measuring procedural and technical skills, radiation dose, and procedure times before and after simulation training. A prospective analysis included 40 radiology residents and eight staff radiologists. Residents took an online pretest to assess baseline procedural knowledge. Second-through fourth-year residents' baseline technical skills with a procedural phantom were evaluated. First-through third-year residents then underwent formal didactic and simulation-based procedural and technical training with one of two interventional radiologists and followed the training with 1 month of supervised phantom-based practice. Thereafter, residents underwent final written and practical examinations. The practical examination included essential items from a 20-point checklist, including site and side marking, consent, time-out, and sterile technique along with a technical skills portion assessing pedal steps, radiation dose, needle redirects, and procedure time. The results indicated statistically significant improvement in procedural and technical skills after simulation training. For residents, the median number of pedal steps decreased by three (p=0.001), median dose decreased by 15.4 mGy (p<0.001), median procedure time decreased by 4.0 minutes (p<0.001), median number of needle redirects decreased by 1.0 (p=0.005), and median number of 20-point checklist items successfully completed increased by three (p<0.001). The results suggest that procedural skills can be acquired and improved by simulation-based training of residents, regardless of experience. CT simulation training decreases procedural time, decreases radiation dose, and improves resident efficiency and confidence, which may transfer to clinical practice with improved patient care and safety.

  17. Automated size-specific CT dose monitoring program: assessing variability in CT dose.

    PubMed

    Christianson, Olav; Li, Xiang; Frush, Donald; Samei, Ehsan

    2012-11-01

    The potential health risks associated with low levels of ionizing radiation have created a movement in the radiology community to optimize computed tomography (CT) imaging protocols to use the lowest radiation dose possible without compromising the diagnostic usefulness of the images. Despite efforts to use appropriate and consistent radiation doses, studies suggest that a great deal of variability in radiation dose exists both within and between institutions for CT imaging. In this context, the authors have developed an automated size-specific radiation dose monitoring program for CT and used this program to assess variability in size-adjusted effective dose from CT imaging. The authors radiation dose monitoring program operates on an independent health insurance portability and accountability act compliant dosimetry server. Digital imaging and communication in medicine routing software is used to isolate dose report screen captures and scout images for all incoming CT studies. Effective dose conversion factors (k-factors) are determined based on the protocol and optical character recognition is used to extract the CT dose index and dose-length product. The patient's thickness is obtained by applying an adaptive thresholding algorithm to the scout images and is used to calculate the size-adjusted effective dose (ED(adj)). The radiation dose monitoring program was used to collect data on 6351 CT studies from three scanner models (GE Lightspeed Pro 16, GE Lightspeed VCT, and GE Definition CT750 HD) and two institutions over a one-month period and to analyze the variability in ED(adj) between scanner models and across institutions. No significant difference was found between computer measurements of patient thickness and observer measurements (p = 0.17), and the average difference between the two methods was less than 4%. Applying the size correction resulted in ED(adj) that differed by up to 44% from effective dose estimates that were not adjusted by patient size

  18. Comparison of TID Effects in Space-Like Variable Dose Rates and Constant Dose Rates

    NASA Technical Reports Server (NTRS)

    Harris, Richard D.; McClure, Steven S.; Rax, Bernard G.; Evans, Robin W.; Jun, Insoo

    2008-01-01

    The degradation of the LM193 dual voltage comparator has been studied at different TID dose rate profiles, including several different constant dose rates and a variable dose rate that simulates the behavior of a solar flare. A comparison of results following constant dose rate vs. variable dose rates is made to explore how well the constant dose rates used for typical part testing predict the performance during a simulated space-like mission. Testing at a constant dose rate equal to the lowest dose rate seen during the simulated flare provides an extremely conservative estimate of the overall amount of degradation. A constant dose rate equal to the average dose rate is also more conservative than the variable rate. It appears that, for this part, weighting the dose rates by the amount of total dose received at each rate (rather than the amount of time at each dose rate) results in an average rate that produces an amount of degradation that is a reasonable approximation to that received by the variable rate.

  19. Cumulative total effective whole-body radiation dose in critically ill patients.

    PubMed

    Rohner, Deborah J; Bennett, Suzanne; Samaratunga, Chandrasiri; Jewell, Elizabeth S; Smith, Jeffrey P; Gaskill-Shipley, Mary; Lisco, Steven J

    2013-11-01

    Uncertainty exists about a safe dose limit to minimize radiation-induced cancer. Maximum occupational exposure is 20 mSv/y averaged over 5 years with no more than 50 mSv in any single year. Radiation exposure to the general population is less, but the average dose in the United States has doubled in the past 30 years, largely from medical radiation exposure. We hypothesized that patients in a mixed-use surgical ICU (SICU) approach or exceed this limit and that trauma patients were more likely to exceed 50 mSv because of frequent diagnostic imaging. Patients admitted into 15 predesignated SICU beds in a level I trauma center during a 30-day consecutive period were prospectively observed. Effective dose was determined using Huda's method for all radiography, CT imaging, and fluoroscopic examinations. Univariate and multivariable linear regressions were used to analyze the relationships between observed values and outcomes. Five of 74 patients (6.8%) exceeded exposures of 50 mSv. Univariate analysis showed trauma designation, length of stay, number of CT scans, fluoroscopy minutes, and number of general radiographs were all associated with increased doses, leading to exceeding occupational exposure limits. In a multivariable analysis, only the number of CT scans and fluoroscopy minutes remained significantly associated with increased whole-body radiation dose. Radiation levels frequently exceeded occupational exposure standards. CT imaging contributed the most exposure. Health-care providers must practice efficient stewardship of radiologic imaging in all critically ill and injured patients. Diagnostic benefit must always be weighed against the risk of cumulative radiation dose.

  20. Medical imaging dose optimisation from ground up: expert opinion of an international summit.

    PubMed

    Samei, Ehsan; Järvinen, Hannu; Kortesniemi, Mika; Simantirakis, George; Goh, Charles; Wallace, Anthony; Vano, Eliseo; Bejan, Adrian; Rehani, Madan; Vassileva, Jenia

    2018-05-17

    As in any medical intervention, there is either a known or an anticipated benefit to the patient from undergoing a medical imaging procedure. This benefit is generally significant, as demonstrated by the manner in which medical imaging has transformed clinical medicine. At the same time, when it comes to imaging that deploys ionising radiation, there is a potential associated risk from radiation. Radiation risk has been recognised as a key liability in the practice of medical imaging, creating a motivation for radiation dose optimisation. The level of radiation dose and risk in imaging varies but is generally low. Thus, from the epidemiological perspective, this makes the estimation of the precise level of associated risk highly uncertain. However, in spite of the low magnitude and high uncertainty of this risk, its possibility cannot easily be refuted. Therefore, given the moral obligation of healthcare providers, 'first, do no harm,' there is an ethical obligation to mitigate this risk. Precisely how to achieve this goal scientifically and practically within a coherent system has been an open question. To address this need, in 2016, the International Atomic Energy Agency (IAEA) organised a summit to clarify the role of Diagnostic Reference Levels to optimise imaging dose, summarised into an initial report (Järvinen et al 2017 Journal of Medical Imaging 4 031214). Through a consensus building exercise, the summit further concluded that the imaging optimisation goal goes beyond dose alone, and should include image quality as a means to include both the benefit and the safety of the exam. The present, second report details the deliberation of the summit on imaging optimisation.

  1. Net financial gain or loss from vaccination in pediatric medical practices.

    PubMed

    Coleman, Margaret S; Lindley, Megan C; Ekong, John; Rodewald, Lance

    2009-12-01

    The goal was to determine the net return (gain or loss after costs were subtracted from revenues) to private pediatric medical practices from investing time and resources in vaccines and vaccination of their patients. A cross-sectional survey of a convenience sample of private medical practices requested data on all financial and capacity aspects of the practices, including operating expenses; labor composition and wages/salaries; private- and public-purchase vaccine orders and inventories; Medicaid and private insurance reimbursements; patient population; numbers of providers; and numbers, types, and lengths of visits. Costs were assigned to vaccination visits and subtracted from reimbursements from public- and private-pay sources to determine net financial gains/losses from vaccination. Thirty-four practices responded to the survey. More than one half of the respondents broke even or suffered financial losses from vaccinating patients. With greater proportions of Medicaid-enrolled patients served, greater financial loss was noted. On average, private insurance vaccine administration reimbursements did not cover administration costs unless a child received > or = 3 doses of vaccine in 1 visit. Finally, wide ranges of per-dose prices paid and reimbursements received for vaccines indicated that some practices might be losing money in purchasing and delivering vaccines for private-pay patients if they pay high purchase prices but receive low reimbursements. We conclude that the vaccination portion of the business model for primary care pediatric practices that serve private-pay patients results in little or no profit from vaccine delivery. When losses from vaccinating publicly insured children are included, most practices lose money.

  2. Dose-response studies and 'no-effect-levels' of N-nitroso compounds: some general aspects.

    PubMed

    Preussmann, R

    1980-01-01

    One major problem in the evaluation of potential carcinogenic food additives and contaminants is that of thresholds or, better, of 'no-adverse-effect-levels'. Arguments in favor of the postulated 'irreversibility' of carcinogenic effects are based on dose-response studies, single dose and multigeneration experiments as well as on the concept of somatic mutation as the first step in carcinogenesis with subsequent transmittance of induced defects during cell replication. The problem of extrapolation of results of animal experiments using high doses to low exposure and low incidences in man is not yet solved satisfactorily. Possible practical consequences include zero tolerance, acceptable thresholds at low risk and safety factors. Acceptable intakes should never be considered constants but should be changeable as soon as new facts in regard to the safety evaluation are available.

  3. Issues to consider before implementing digital breast tomosynthesis into a breast imaging practice.

    PubMed

    Hardesty, Lara A

    2015-03-01

    OBJECTIVE. The purpose of this article is to discuss issues surrounding the implementation of digital breast tomosynthesis (DBT) into a clinical breast imaging practice and assist radiologists, technologists, and administrators who are considering the addition of this new technology to their practices. CONCLUSION. When appropriate attention is given to image acquisition, interpretation, storage, technologist and radiologist training, patient selection, billing, radiation dose, and marketing, implementation of DBT into a breast imaging practice can be successful.

  4. Consensus on Insulin Dose and Titration Algorithms in Ambulatory Care of Type 2 Diabetes in India.

    PubMed

    Kovil, Rajiv; Chawla, Manoj; Rajput, Rajesh; Singh, A K; Sinha, Binayak; Ghosal, Samit; Ballani, Piya; Gupta, Sunil; Tanna, Snehal; Bandukwala, S M; Shah, Tejas; Negalur, Vijay; Bhoraskar, Anil; Aravind, S R; Zargar, Abdul H; Kesavadev, Jothydev; Das, Ashok Kumar

    2017-02-01

    Insulin is the oldest of the currently available treatment options in Type 2 diabetes mellitus (T2DM) and is considered as the most effective glucose lowering agent. Despite this, decision on starting insulin therapy is often delayed in India as well as worldwide due to various barriers at both patient and physician levels. Appropriate insulin dosing and titration is also critical to the successful achievement of tight glycaemic control. To provide simple and easily implementable guidelines to primary care physicians on appropriate insulin dosing and titration of various insulin regimens for both initiation and intensification. Each insulin regimen (once daily [OD] basal, OD, twice daily and thrice daily premixed, basal-plus and basal-bolus) was presented and evaluated for dosing and titration based on established guidelines, data from approved pack inserts, and published scientific literature. These evaluations were then factored into the national context based on the expert committee representatives patient-physician experience in their clinical practice and common therapeutic practices followed in India. Recommendations for dosing and titration of basal, basal-plus, premixed and basal-bolus insulins were developed. The key recommendations are that insulin doses can be adjusted once or twice weekly; adjustment can be based on lowest/mean of three recent self-monitoring of plasma glucose pre-meal/fasting plasma glucose (FPG) values. The titration should be based on FPG or pre-meal value of 80-130 mg/dL and the dose should be reduced by 10-20% for patients reporting hypoglycaemia(<70mg/dL). The consensus based recommendations mentioned in this paper will be a useful reference tool for health care practitioners, to initiate, optimise and intensify insulin therapy and to successfully achieve optimal glucose control.

  5. Dose specification for 192Ir high dose rate brachytherapy in terms of dose-to-water-in-medium and dose-to-medium-in-medium

    NASA Astrophysics Data System (ADS)

    Paiva Fonseca, Gabriel; Carlsson Tedgren, Åsa; Reniers, Brigitte; Nilsson, Josef; Persson, Maria; Yoriyaz, Hélio; Verhaegen, Frank

    2015-06-01

    Dose calculation in high dose rate brachytherapy with 192Ir is usually based on the TG-43U1 protocol where all media are considered to be water. Several dose calculation algorithms have been developed that are capable of handling heterogeneities with two possibilities to report dose: dose-to-medium-in-medium (Dm,m) and dose-to-water-in-medium (Dw,m). The relation between Dm,m and Dw,m for 192Ir is the main goal of this study, in particular the dependence of Dw,m on the dose calculation approach using either large cavity theory (LCT) or small cavity theory (SCT). A head and neck case was selected due to the presence of media with a large range of atomic numbers relevant to tissues and mass densities such as air, soft tissues and bone interfaces. This case was simulated using a Monte Carlo (MC) code to score: Dm,m, Dw,m (LCT), mean photon energy and photon fluence. Dw,m (SCT) was derived from MC simulations using the ratio between the unrestricted collisional stopping power of the actual medium and water. Differences between Dm,m and Dw,m (SCT or LCT) can be negligible (<1%) for some tissues e.g. muscle and significant for other tissues with differences of up to 14% for bone. Using SCT or LCT approaches leads to differences between Dw,m (SCT) and Dw,m (LCT) up to 29% for bone and 36% for teeth. The mean photon energy distribution ranges from 222 keV up to 356 keV. However, results obtained using mean photon energies are not equivalent to the ones obtained using the full, local photon spectrum. This work concludes that it is essential that brachytherapy studies clearly report the dose quantity. It further shows that while differences between Dm,m and Dw,m (SCT) mainly depend on tissue type, differences between Dm,m and Dw,m (LCT) are, in addition, significantly dependent on the local photon energy fluence spectrum which varies with distance to implanted sources.

  6. Real-life GH dosing patterns in children with GHD, TS or born SGA: a report from the NordiNet® International Outcome Study.

    PubMed

    Blankenstein, Oliver; Snajderova, Marta; Blair, Jo; Pournara, Effie; Pedersen, Birgitte Tønnes; Petit, Isabelle Oliver

    2017-08-01

    To describe real-life dosing patterns in children with growth hormone deficiency (GHD), born small for gestational age (SGA) or with Turner syndrome (TS) receiving growth hormone (GH) and enrolled in the NordiNet International Outcome Study (IOS; Nbib960128) between 2006 and 2016. This non-interventional, multicentre study included paediatric patients diagnosed with GHD (isolated (IGHD) or multiple pituitary hormone deficiency (MPHD)), born SGA or with TS and treated according to everyday clinical practice from the Czech Republic (IGHD/MPHD/SGA/TS: n  = 425/61/316/119), France ( n  = 1404/188/970/206), Germany ( n  = 2603/351/1387/411) and the UK ( n  = 259/60/87/35). GH dosing was compared descriptively across countries and indications. Proportions of patients by GH dose group (low/medium/high) or GH dose change (decrease/increase/no change) during years 1 and 2 were also evaluated across countries and indications. In the Czech Republic, GH dosing was generally within recommended levels. In France, average GH doses were higher for patients with IGHD, MPHD and SGA than in other countries. GH doses in TS tended to be at the lower end of the recommended label range, especially in Germany and the UK; the majority of patients were in the low-dose group. A significant inverse association between baseline height standard deviation score and GH dose was shown ( P  < 0.05); shorter patients received higher doses. Changes in GH dose, particularly increases, were more common in the second (40%) than in the first year (25%). GH dosing varies considerably across countries and indications. In particular, almost half of girls with TS received GH doses below practice guidelines and label recommendations. © 2017 The authors.

  7. Real-life GH dosing patterns in children with GHD, TS or born SGA: a report from the NordiNet® International Outcome Study

    PubMed Central

    Snajderova, Marta; Blair, Jo; Pournara, Effie; Pedersen, Birgitte Tønnes; Petit, Isabelle Oliver

    2017-01-01

    Objective To describe real-life dosing patterns in children with growth hormone deficiency (GHD), born small for gestational age (SGA) or with Turner syndrome (TS) receiving growth hormone (GH) and enrolled in the NordiNet International Outcome Study (IOS; Nbib960128) between 2006 and 2016. Design This non-interventional, multicentre study included paediatric patients diagnosed with GHD (isolated (IGHD) or multiple pituitary hormone deficiency (MPHD)), born SGA or with TS and treated according to everyday clinical practice from the Czech Republic (IGHD/MPHD/SGA/TS: n = 425/61/316/119), France (n = 1404/188/970/206), Germany (n = 2603/351/1387/411) and the UK (n = 259/60/87/35). Methods GH dosing was compared descriptively across countries and indications. Proportions of patients by GH dose group (low/medium/high) or GH dose change (decrease/increase/no change) during years 1 and 2 were also evaluated across countries and indications. Results In the Czech Republic, GH dosing was generally within recommended levels. In France, average GH doses were higher for patients with IGHD, MPHD and SGA than in other countries. GH doses in TS tended to be at the lower end of the recommended label range, especially in Germany and the UK; the majority of patients were in the low-dose group. A significant inverse association between baseline height standard deviation score and GH dose was shown (P < 0.05); shorter patients received higher doses. Changes in GH dose, particularly increases, were more common in the second (40%) than in the first year (25%). Conclusions GH dosing varies considerably across countries and indications. In particular, almost half of girls with TS received GH doses below practice guidelines and label recommendations. PMID:28522645

  8. EFFECT OF MODERATE DOSES OF GAMMA RADIATION ON THE KEEPING QUALITY OF BILBERRIES (VACCINIUM MYRTILLUS)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Horubala, A.; Pijanowski, E.

    1961-01-01

    Three batches of bilberries (European blueberries) in small polythene bags were treated with various doses of gamma radiation and kept afterwards either at ambient or cool storage temperatures for about 10 to 25 days. The dose of about 0.3 Mrad caused the destruction of somewhat more than 99% of the original microflora (bacteria, yeasts and moulds) and thus increased by 250 to 300% the storage life of berries in comparison with untreated fruit. Losses of anthocyanin pigments, vitamin C, and jellifying power were rather small, and the subsequent changes in flavor were practically non existant. The authors recommend the applicationmore » of moderate doses of gamma -rays (about 0.3 Mrad) to exported bilberries prior to their shipment. (auth)« less

  9. Radiation dose evaluation of dental cone beam computed tomography using an anthropomorphic adult head phantom

    NASA Astrophysics Data System (ADS)

    Wu, Jay; Shih, Cheng-Ting; Ho, Chang-hung; Liu, Yan-Lin; Chang, Yuan-Jen; Min Chao, Max; Hsu, Jui-Ting

    2014-11-01

    Dental cone beam computed tomography (CBCT) provides high-resolution tomographic images and has been gradually used in clinical practice. Thus, it is important to examine the amount of radiation dose resulting from dental CBCT examinations. In this study, we developed an in-house anthropomorphic adult head phantom to evaluate the level of effective dose. The anthropomorphic phantom was made of acrylic and filled with plaster to replace the bony tissue. The contour of the head was extracted from a set of adult computed tomography (CT) images. Different combinations of the scanning parameters of CBCT were applied. Thermoluminescent dosimeters (TLDs) were used to measure the absorbed doses at 19 locations in the head and neck regions. The effective doses measured using the proposed phantom at 65, 75, and 85 kVp in the D-mode were 72.23, 100.31, and 134.29 μSv, respectively. In the I-mode, the effective doses were 108.24, 190.99, and 246.48 μSv, respectively. The maximum percent error between the doses measured by the proposed phantom and the Rando phantom was l4.90%. Therefore, the proposed anthropomorphic adult head phantom is applicable for assessing the radiation dose resulting from clinical dental CBCT.

  10. Automated size-specific CT dose monitoring program: Assessing variability in CT dose

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Christianson, Olav; Li Xiang; Frush, Donald

    2012-11-15

    Purpose: The potential health risks associated with low levels of ionizing radiation have created a movement in the radiology community to optimize computed tomography (CT) imaging protocols to use the lowest radiation dose possible without compromising the diagnostic usefulness of the images. Despite efforts to use appropriate and consistent radiation doses, studies suggest that a great deal of variability in radiation dose exists both within and between institutions for CT imaging. In this context, the authors have developed an automated size-specific radiation dose monitoring program for CT and used this program to assess variability in size-adjusted effective dose from CTmore » imaging. Methods: The authors radiation dose monitoring program operates on an independent health insurance portability and accountability act compliant dosimetry server. Digital imaging and communication in medicine routing software is used to isolate dose report screen captures and scout images for all incoming CT studies. Effective dose conversion factors (k-factors) are determined based on the protocol and optical character recognition is used to extract the CT dose index and dose-length product. The patient's thickness is obtained by applying an adaptive thresholding algorithm to the scout images and is used to calculate the size-adjusted effective dose (ED{sub adj}). The radiation dose monitoring program was used to collect data on 6351 CT studies from three scanner models (GE Lightspeed Pro 16, GE Lightspeed VCT, and GE Definition CT750 HD) and two institutions over a one-month period and to analyze the variability in ED{sub adj} between scanner models and across institutions. Results: No significant difference was found between computer measurements of patient thickness and observer measurements (p= 0.17), and the average difference between the two methods was less than 4%. Applying the size correction resulted in ED{sub adj} that differed by up to 44% from effective dose

  11. Developability assessment of clinical drug products with maximum absorbable doses.

    PubMed

    Ding, Xuan; Rose, John P; Van Gelder, Jan

    2012-05-10

    Maximum absorbable dose refers to the maximum amount of an orally administered drug that can be absorbed in the gastrointestinal tract. Maximum absorbable dose, or D(abs), has proved to be an important parameter for quantifying the absorption potential of drug candidates. The purpose of this work is to validate the use of D(abs) in a developability assessment context, and to establish appropriate protocol and interpretation criteria for this application. Three methods for calculating D(abs) were compared by assessing how well the methods predicted the absorption limit for a set of real clinical candidates. D(abs) was calculated for these clinical candidates by means of a simple equation and two computer simulation programs, GastroPlus and an program developed at Eli Lilly and Company. Results from single dose escalation studies in Phase I clinical trials were analyzed to identify the maximum absorbable doses for these compounds. Compared to the clinical results, the equation and both simulation programs provide conservative estimates of D(abs), but in general D(abs) from the computer simulations are more accurate, which may find obvious advantage for the simulations in developability assessment. Computer simulations also revealed the complex behavior associated with absorption saturation and suggested in most cases that the D(abs) limit is not likely to be achieved in a typical clinical dose range. On the basis of the validation findings, an approach is proposed for assessing absorption potential, and best practices are discussed for the use of D(abs) estimates to inform clinical formulation development strategies. Copyright © 2012 Elsevier B.V. All rights reserved.

  12. Problems in evaluating radiation dose via terrestrial and aquatic pathways.

    PubMed Central

    Vaughan, B E; Soldat, J K; Schreckhise, R G; Watson, E C; McKenzie, D H

    1981-01-01

    This review is concerned with exposure risk and the environmental pathways models used for predictive assessment of radiation dose. Exposure factors, the adequacy of available data, and the model subcomponents are critically reviewed from the standpoint of absolute error propagation. Although the models are inherently capable of better absolute accuracy, a calculated dose is usually overestimated by from two to six orders of magnitude, in practice. The principal reason for so large an error lies in using "generic" concentration ratios in situations where site specific data are needed. Major opinion of the model makers suggests a number midway between these extremes, with only a small likelihood of ever underestimating the radiation dose. Detailed evaluations are made of source considerations influencing dose (i.e., physical and chemical status of released material); dispersal mechanisms (atmospheric, hydrologic and biotic vector transport); mobilization and uptake mechanisms (i.e., chemical and other factors affecting the biological availability of radioelements); and critical pathways. Examples are shown of confounding in food-chain pathways, due to uncritical application of concentration ratios. Current thoughts of replacing the critical pathways approach to calculating dose with comprehensive model calculations are also shown to be ill-advised, given present limitations in the comprehensive data base. The pathways models may also require improved parametrization, as they are not at present structured adequately to lend themselves to validation. The extremely wide errors associated with predicting exposure stand in striking contrast to the error range associated with the extrapolation of animal effects data to the human being. PMID:7037381

  13. The use of TLD-700H dosemeters in the assessment of external doses at the former Semipalatinsk nuclear test site.

    PubMed

    Hill, P; Dederichs, H; Pillath, J; Schlecht, W; Hille, R; Artemev, O; Ptitskaya, L; Akhmetov, M

    2002-01-01

    The joint projects performed since 1995 by the Jülich Research Centre in co-operation with the Kazakh National Nuclear Centre in the area of the former nuclear test site near Semipalatinsk, in eastern Kazakhstan, have assessed the current dose rate of the population at and around the test site, as well as determining retrospectively the dose rate of persons affected by the atmospheric tests. Measurements of the population by personal dosemeters depend on reliably wearing these dosemeters over prolonged periods of time, and of a sufficient dosemeter return. In the past, such measurements have been particularly successful whenever short wearing times were possible. This requires high sensitivity of the dosemeters. The suitability of the highly sensitive TLD material of the BICRON TLD 700H type for such personal dosimetry measurements was investigated. It was tested in practical field application at the Semipalatinsk nuclear test site in September 2000. Initial results are available from individual doses received by a group of geologists and a group of herdsmen at the test site. For the first time, the individual dose was measured directly in these population groups. Detection limits below 1 microSv permit informative measurements for wearing times of less than two weeks. Most individual doses did not arise significantly out of local fluctuations of natural background. A conservative assessment from the aspect of practical health physics yielded a mean personal dose of 0.55 microSv per day for the herdsmen, whereas the geologists received a mean personal dose of 0.45 microSv per day. For an annual exposure period of typically, about three months, the radiation dose received by the persons investigated, in addition to the natural radiation exposure, is thus well below the international limit value of 1 mSv x a(-1) for the population dose.

  14. The American brachytherapy society survey of brachytherapy practice for carcinoma of the cervix in the United States.

    PubMed

    Nag, S; Orton, C; Young, D; Erickson, B

    1999-04-01

    The purpose of this study was to survey the brachytherapy practice for cervical cancer in the United States. The Clinical Research Committee of the American Brachytherapy Society (ABS) performed a retrospective survey of individual physicians of the ABS and American Society of Therapeutic Radiologists and Oncologists regarding the details of the brachytherapy techniques they personally used in the treatment of cervical cancer patients for the year 1995. The replies (some of which may have been an estimate only) were tabulated. The scope of this survey did not allow us to verify the data by chart audits. A total of about 3500 questionnaires were mailed out; 521 responses were received. Of these responders, 206 (40%) did not perform any brachytherapy for carcinoma of the cervix in 1995. Of the other 315 responders reporting a total of 4892 patients treated in 1995, 88% used low dose rate (LDR) while 24% used high dose rate (HDR). There was a wide variation in the doses used. For LDR treatments, the median total external beam radiation therapy (EBRT) dose was 45 and 50 Gy and the LDR dose was 42 and 45 Gy for early and advanced cancers, respectively. For HDR treatments, the median EBRT dose was 48 and 50 Gy and the median HDR dose was 29 and 30 Gy for early and advanced cancers, respectively. The median dose per fraction was 6 Gy for a median of five fractions. Interstitial brachytherapy was used as a component of the treatment in 6% of the patients by 21% of responders. Very few responders treated with pulsed or medium dose rates. This retrospective survey showed the current brachytherapy practice pattern in the treatment of cervical cancer in the United States and can serve as a basis for future prospective national brachytherapy data registry. There was wide variation in the practice pattern, emphasizing the urgent need for consensus on these issues. Copyright 1999 Academic Press.

  15. Mobile-Dose: A Dose-Meter Designed for Use in Automatic Machineries for Dose Manipulation in Nuclear Medicine

    NASA Astrophysics Data System (ADS)

    de Asmundis, Riccardo; Boiano, Alfonso; Ramaglia, Antonio

    2008-06-01

    Mobile-Dose has been designed for a very innovative use: the integration in a robotic machinery for automatic preparation of radioactive doses, to be injected to patients in Nuclear Medicine Departments, with real time measurement of the activity under preparation. Mobile-Dose gives a constant measurement of the dose during the filling of vials or syringes, triggering the end of the filling process based on a predefined dose limit. Several applications of Mobile-Dose have been delivered worldwide, from Italian hospitals and clinics to European and Japanese ones. The design of such an instrument and its integration in robotic machineries, was required by an Italian company specialised in radiation protection tools for nuclear applications, in the period 2001-2003. At the time of its design, apparently no commercial instruments with a suitable interfacing capability to the external world existed: we designed it in order to satisfy all the strict requirements coming from the medical aspects (precision within 10%, repeatability, stability, time response) and from the industrial conceiving principles that are mandatory to ensure a good reliability in such a complicated environment. The instrument is suitable to be used in standalone mode too, thanks to its portability and compactness and to the intelligent operator panel programmed for this purpose.

  16. Low-Dose Carcinogenicity Studies

    EPA Science Inventory

    One of the major deficiencies of cancer risk assessments is the lack of low-dose carcinogenicity data. Most assessments require extrapolation from high to low doses, which is subject to various uncertainties. Only 4 low-dose carcinogenicity studies and 5 low-dose biomarker/pre-n...

  17. Caudal anesthesia in pediatric surgical practice.

    PubMed

    Rahman, S; Siddiqui, M A; Haque, M; Majumder, S K; Ali, M S; Majid, M A; Hasan, M R

    2006-07-01

    Prospective study was carried out on 100 patients since May 2005 in my private practice and in the department of pediatric surgery of MMCH. Under caudal anesthesia along with or without ketaminie induction and gas inhalation all the patients underwent different surgical procedure namely anorectal surgery (eg. anoplasty, rectal polyp), urogenital surgery (Circumcision, hypospadias, meatotomy), groin surgery (hernia, hydrocele) and foot & leg surgery. Calculated dose schedule of drugs used in anesthesia and volume were maintained. Time of giving anesthesia and time of starting analgesia were recorded. Per-operative and postoperative analgesia were evaluated. Every parent was explained regarding the merit of caudal anesthesia calculated and compared with that of general anesthesia. Application of caudal anesthesia with or without ketamine & diazepam induction can be used safely and cost effectively and may be put into protocol in many of the pediatric surgical practice both in institute and also in private practice.

  18. Effect of high doses of 2-CdA on Schwann cells of mouse peripheral nerve.

    PubMed

    Djaldetti, R; Hart, J; Alexandrova, S; Cohen, S; Beilin, B; Djaldetti, M; Bessler, H

    1996-07-01

    The present study was undertaken to examine the effect of 2-CdA (Leustatin) on the Schwann cells of myelinated and unmyelinated fibers of peripheral mouse nerve. Two groups of mice were injected intravenously for seven days with 2-CdA: one group received daily doses of 1 mg/kg and the other 0.5 mg/kg. Both doses exceeded those accepted in clinical practice. Mice injected with saline served as controls. The sciatic nerve was then dissected and examined with a transmission electron microscope. The Schwann cells of both the myelinated and unmyelinated nerve fibers of the animals receiving the higher doses of 2-CdA showed nuclear and nucleolus damage, loss of heterochromatin, vacuolization and disorganization of the myelin sheaths. The mesaxons and the axons were also damaged. The Schwann cells of the animals treated with the lower doses appeared undamaged. The results indicate that in contrast to other anticancer drugs known to produce peripheral neuropathy, 2-CdA may cause damage to the Schwann cells only at doses exceeding the therapeutic ones.

  19. A naturalistic study of high-dose unilateral ECT among severely depressed inpatients: how does it work in the clinical practice?

    PubMed

    Alves, Lucas P C; Freire, Thiago F V; Fleck, Marcelo P A; Rocha, Neusa S

    2016-11-11

    Naturalistic studies can be useful tools to understand how an intervention works in the real clinical practice. This study aims to investigate the outcomes in a naturalistically treated depressed inpatients cohort, who were referred, or not, to unilateral ECT. Depressed adults according to MINI admitted in a psychiatric unit were divided in unilateral ECT treated and non-ECT treated. Main outcomes were: depression improvement in Hamilton Rating Scale for Depression (HDRS-17) scores; response (HDRS-17 improvement ≥50 %); remission (HDRS-17 score ≤7); length of hospitalization. Forty-three patients were included in unilateral ECT group and 104 in non-ECT group. No differences of psychotic symptoms, melancholic features or past maniac episode were found between groups. Unilateral ECT group had a mean HDRS-17 score higher than non-ECT group at admission (ECT: 25.05 ± 1.03; non-ECT: 21.61 ± 0.69; p = 0.001), but no significant difference was found at discharge (ECT: 7.70 ± 0.81; non-ECT: 7.40 ± 0.51; p = 0.75). Unilateral ECT group had a larger HDRS-17 score reduction during treatment (ECT: 18.24 ± 1.18; non-ECT:14.20 ± 0.76; p = 0.004). There were no significant differences in response and remission rates between groups. Unilateral ECT group had longer mean duration of hospitalization in days (ECT: 35.48 ± 2.48; non-ECT: 24.57 ± 1.50; p < 0.001), but there were no difference in mean time of treatment (ECT group:27.66 ± 1.95; non-ECT: 24.57 ± 1.50; p = 0.25). Unilateral high-dose ECT is still a useful treatment option, in the real world clinical practice, to reduce the intensity of depressive symptoms in highly depressed inpatients.

  20. Automated extraction of radiation dose information from CT dose report images.

    PubMed

    Li, Xinhua; Zhang, Da; Liu, Bob

    2011-06-01

    The purpose of this article is to describe the development of an automated tool for retrieving texts from CT dose report images. Optical character recognition was adopted to perform text recognitions of CT dose report images. The developed tool is able to automate the process of analyzing multiple CT examinations, including text recognition, parsing, error correction, and exporting data to spreadsheets. The results were precise for total dose-length product (DLP) and were about 95% accurate for CT dose index and DLP of scanned series.

  1. Prospects for the Rule of Law in Cyberspace

    DTIC Science & Technology

    2017-01-01

    a de facto norm being outsourced to the private sector—since the U.S. Government and other countries have, in effect, delegated the task—cor...encountered less resistance from the cybersecurity community, but it is still under scru- tiny by researchers who vehemently oppose any ex - port...and reli- able Internet; • Using the OSCE as a platform for dialogue, ex - changing best practices, awareness-raising, and information on capacity

  2. Dose to ‘water-like’ media or dose to tissue in MV photons radiotherapy treatment planning: still a matter of debate

    NASA Astrophysics Data System (ADS)

    Andreo, Pedro

    2015-01-01

    The difference between Monte Carlo Treatment Planning (MCTP) based on the assumption of ‘water-like’ tissues with densities obtained from CT procedures, or on tissue compositions derived from CT-determined densities, have been investigated. Stopping powers and electron fluences have been calculated for a range of media and body tissues for 6 MV photon beams, including changes in their physical data (density and stopping powers). These quantities have been used to determine absorbed doses using cavity theory. It is emphasized that tissue compositions given in ICRU or ICRP reports should not be given the standing of physical constants as they correspond to average values obtained for a limited number of human-body samples. It has been shown that mass stopping-power ratios to water are more dependent on patient-to-patient composition differences, and therefore on their mean excitation energies (I-values), than on mass density. Electron fluence in different media are also more dependent on media composition (and their I-values) than on density. However, as a consequence of the balance between fluence and stopping powers, doses calculated from their product are more constant than what the independent stopping powers and fluence variations suggest. Additionally, cancelations in dose ratios minimize the differences between the ‘water-like’ and ‘tissue’ approaches, yielding practically identical results except for bone, and to a lesser extent for adipose tissue. A priori, changing from one approach to another does not seem to be justified considering the large number of approximations and uncertainties involved throughout the treatment planning tissue segmentation and dose calculation procedures. The key issue continues to be the composition of tissues and their I-values, and as these cannot be obtained for individual patients, whatever approach is selected does not lead to significant differences from a water reference dose, the maximum of these being of the

  3. [Clinical applications of dosing algorithm in the predication of warfarin maintenance dose].

    PubMed

    Huang, Sheng-wen; Xiang, Dao-kang; An, Bang-quan; Li, Gui-fang; Huang, Ling; Wu, Hai-li

    2011-12-27

    To evaluate the feasibility of clinical application for genetic based dosing algorithm in the predication of warfarin maintenance dose in Chinese population. The clinical data were collected and blood samples harvested from a total of 126 patients undergoing heart valve replacement. The genotypes of VKORC1 and CYP2C9 were determined by melting curve analysis after PCR. They were divided randomly into the study and control groups. In the study group, the first three doses of warfarin were prescribed according to the predicted warfarin maintenance dose while warfarin was initiated at 2.5 mg/d in the control group. The warfarin doses were adjusted according to the measured international normalized ratio (INR) values. And all subjects were followed for 50 days after an initiation of warfarin therapy. At the end of a 50-day follow-up period, the proportions of the patients on a stable dose were 82.4% (42/51) and 62.5% (30/48) for the study and control groups respectively. The mean durations of reaching a stable dose of warfarin were (27.5 ± 1.8) and (34.7 ± 1.8) days and the median durations were (24.0 ± 1.7) and (33.0 ± 4.5) days in the study and control groups respectively. Significant differences existed in the durations of reaching a stable dose between the two groups (P = 0.012). Compared with the control group, the hazard ratio (HR) for the duration of reaching a stable dose was 1.786 in the study group (95%CI 1.088 - 2.875, P = 0.026). The predicted dosing algorithm incorporating genetic and non-genetic factors may shorten the duration of achieving efficiently a stable dose of warfarin. And the present study validates the feasibility of its clinical application.

  4. Psilocybin-occasioned mystical-type experience in combination with meditation and other spiritual practices produces enduring positive changes in psychological functioning and in trait measures of prosocial attitudes and behaviors.

    PubMed

    Griffiths, Roland R; Johnson, Matthew W; Richards, William A; Richards, Brian D; Jesse, Robert; MacLean, Katherine A; Barrett, Frederick S; Cosimano, Mary P; Klinedinst, Maggie A

    2018-01-01

    Psilocybin can occasion mystical-type experiences with participant-attributed increases in well-being. However, little research has examined enduring changes in traits. This study administered psilocybin to participants who undertook a program of meditation/spiritual practices. Healthy participants were randomized to three groups (25 each): (1) very low-dose (1 mg/70 kg on sessions 1 and 2) with moderate-level ("standard") support for spiritual-practice (LD-SS); (2) high-dose (20 and 30 mg/70 kg on sessions 1 and 2, respectively) with standard support (HD-SS); and (3) high-dose (20 and 30 mg/70kg on sessions 1 and 2, respectively) with high support for spiritual practice (HD-HS). Psilocybin was administered double-blind and instructions to participants/staff minimized expectancy confounds. Psilocybin was administered 1 and 2 months after spiritual-practice initiation. Outcomes at 6 months included rates of spiritual practice and persisting effects of psilocybin. Compared with low-dose, high-dose psilocybin produced greater acute and persisting effects. At 6 months, compared with LD-SS, both high-dose groups showed large significant positive changes on longitudinal measures of interpersonal closeness, gratitude, life meaning/purpose, forgiveness, death transcendence, daily spiritual experiences, religious faith and coping, and community observer ratings. Determinants of enduring effects were psilocybin-occasioned mystical-type experience and rates of meditation/spiritual practices. Psilocybin can occasion enduring trait-level increases in prosocial attitudes/behaviors and in healthy psychological functioning. Trial Registration ClinicalTrials.gov Identifier NCT00802282.

  5. Psilocybin-occasioned mystical-type experience in combination with meditation and other spiritual practices produces enduring positive changes in psychological functioning and in trait measures of prosocial attitudes and behaviors

    PubMed Central

    Griffiths, Roland R; Johnson, Matthew W; Richards, William A; Richards, Brian D; Jesse, Robert; MacLean, Katherine A; Barrett, Frederick S; Cosimano, Mary P; Klinedinst, Maggie A

    2017-01-01

    Psilocybin can occasion mystical-type experiences with participant-attributed increases in well-being. However, little research has examined enduring changes in traits. This study administered psilocybin to participants who undertook a program of meditation/spiritual practices. Healthy participants were randomized to three groups (25 each): (1) very low-dose (1 mg/70 kg on sessions 1 and 2) with moderate-level (“standard”) support for spiritual-practice (LD-SS); (2) high-dose (20 and 30 mg/70 kg on sessions 1 and 2, respectively) with standard support (HD-SS); and (3) high-dose (20 and 30 mg/70kg on sessions 1 and 2, respectively) with high support for spiritual practice (HD-HS). Psilocybin was administered double-blind and instructions to participants/staff minimized expectancy confounds. Psilocybin was administered 1 and 2 months after spiritual-practice initiation. Outcomes at 6 months included rates of spiritual practice and persisting effects of psilocybin. Compared with low-dose, high-dose psilocybin produced greater acute and persisting effects. At 6 months, compared with LD-SS, both high-dose groups showed large significant positive changes on longitudinal measures of interpersonal closeness, gratitude, life meaning/purpose, forgiveness, death transcendence, daily spiritual experiences, religious faith and coping, and community observer ratings. Determinants of enduring effects were psilocybin-occasioned mystical-type experience and rates of meditation/spiritual practices. Psilocybin can occasion enduring trait-level increases in prosocial attitudes/behaviors and in healthy psychological functioning. Trial Registration ClinicalTrials.gov Identifier NCT00802282 PMID:29020861

  6. Direct dosing of preweaning rodents in toxicity testing and research: deliberations of an ILSI RSI Expert Working Group.

    PubMed

    Moser, Virginia C; Walls, Isabel; Zoetis, Tracey

    2005-01-01

    Laboratory animal studies designed to assess the effects of exposure of a test substance during postnatal development are commonly utilized in basic research and to evaluate potential hazard to children for chemical and pharmaceutical regulation. Direct dosing, defined here as the administration of a test substance directly to a preweaning mammal, has been identified as a useful tool that can be used in the conduct of such studies for regulatory purposes. The International Life Sciences Institute Risk Science Institute (ILSI RSI) convened an Expert Working Group to develop guidance on the design and implementation of direct dosing regulatory studies on preweaning mammals, which was published as an ILSI monograph in 2003 (Zoetis and Walls, Principles and Practices for Direct Dosing of Pre-Weaning Mammals in Toxicity Testing and Research, Washington, DC: ILSI Press, 2003). A summary of the Working Group conclusions regarding direct dosing studies with laboratory rodents are presented here, although the ILSI monograph also includes rabbits, canines, swine and nonhuman primates. Issues to be considered when designing the protocol include selection of the test species, the route of administration, dose levels, and the timing of dosing. Knowledge of the maturational status of the test species and information on critical windows of development are important in creating a valid study design. Most common routes of administration (e.g., oral, inhalation, injection) are possible with typical laboratory species; however, adjustments may be necessary due to practical considerations. Information on the pharmacokinetic profile in young animals versus adults and in the test species versus humans is very useful for determining dosing parameters. The conduct of the study and the interpretation of the data will be improved by an understanding of confounding factors as well as statistical and biological issues specific for postnatal studies. Ultimately, the success of the study will

  7. Individual dose adjustment of riociguat in patients with pulmonary arterial hypertension and chronic thromboembolic pulmonary hypertension.

    PubMed

    Hill, Nicholas S; Rahaghi, Franck F; Sood, Namita; Frey, Reiner; Ghofrani, Hossein-Ardeschir

    2017-08-01

    Riociguat is a soluble guanylate cyclase stimulator that has been approved for the treatment of pulmonary arterial hypertension and inoperable chronic thromboembolic pulmonary hypertension or persistent/recurrent pulmonary hypertension following pulmonary endarterectomy. Riociguat is administered using an 8-week individual dose-adjustment scheme whereby a patient initially receives riociguat 1.0 mg three times daily (tid), and the dose is then increased every 2 weeks in the absence of hypotension, indicated by systolic blood pressure measurements and symptoms, up to a maximum dose of 2.5 mg tid. The established riociguat dose-adjustment scheme allows the dose of riociguat to be individually optimized in terms of tolerability and efficacy. The majority of patients in the phase III clinical trials and their long-term extension phases achieved the maximum riociguat dose, whereas some patients remained on lower doses. There is evidence that these patients may experience benefits at riociguat doses lower than 2.5 mg tid, with improvement in exercise capacity being observed after only 2-4 weeks of treatment in the phase III studies and in the exploratory 1.5 mg-maximum patient group of PATENT-1. This review aims to provide an overview of the rationale behind the riociguat dose-adjustment scheme and examine its application to both clinical trials and real-life clinical practice. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. A single institution study of radiation dose received from CT imaging: A comparison to Malaysian NDRL

    NASA Astrophysics Data System (ADS)

    Osman, N. D.; Shamsuri, S. B. M.; Tan, Y. W.; Razali, M. A. S. M.; Isa, S. M.

    2017-05-01

    Advancement of CT technology has led to an increase in CT scanning as it improves the diagnosis. However, it is important to assess health risk of patients associated with ionising radiation received from CT. This study evaluated current dose distributions at Advanced Medical and Dental Institute (AMDI), Malaysia and was used to establish Local Diagnostic Reference Level (LDRL). Dose indicators such as CT Dose Index (CTDIvol and CTDIw) and Dose-Length Product (DLP) were gathered for all routine CT examinations performed at the Imaging Unit, AMDI from January 2015 to June 2016. The first and third quartile values for each dose indicator were determined. A total of 364 CT studies were performed during that period with the highest number of cases being Thorax-Abdomen-Pelvis (TAP) study (57% of total study). The CTDIw ranged between 2.0 mGy to 23.4 mGy per procedure. DLP values were ranged between 94 mGy.cm to 1687 mGy.cm. The local dose data was compared with the national DRL to monitor the current CT practice at AMDI and LDRL will be established from the calculated third quartile values of dose distribution. From the results, some of the local dose values exceeded the Malaysian and further evaluation is important to ensure the dose optimisation for patients.

  9. In vivo dose verification method in catheter based high dose rate brachytherapy.

    PubMed

    Jaselskė, Evelina; Adlienė, Diana; Rudžianskas, Viktoras; Urbonavičius, Benas Gabrielis; Inčiūra, Arturas

    2017-12-01

    In vivo dosimetry is a powerful tool for dose verification in radiotherapy. Its application in high dose rate (HDR) brachytherapy is usually limited to the estimation of gross errors, due to inability of the dosimetry system/ method to record non-uniform dose distribution in steep dose gradient fields close to the radioactive source. In vivo dose verification in interstitial catheter based HDR brachytherapy is crucial since the treatment is performed inserting radioactive source at the certain positions within the catheters that are pre-implanted into the tumour. We propose in vivo dose verification method for this type of brachytherapy treatment which is based on the comparison between experimentally measured and theoretical dose values calculated at well-defined locations corresponding dosemeter positions in the catheter. Dose measurements were performed using TLD 100-H rods (6 mm long, 1 mm diameter) inserted in a certain sequences into additionally pre-implanted dosimetry catheter. The adjustment of dosemeter positioning in the catheter was performed using reconstructed CT scans of patient with pre-implanted catheters. Doses to three Head&Neck and one Breast cancer patient have been measured during several randomly selected treatment fractions. It was found that the average experimental dose error varied from 4.02% to 12.93% during independent in vivo dosimetry control measurements for selected Head&Neck cancer patients and from 7.17% to 8.63% - for Breast cancer patient. Average experimental dose error was below the AAPM recommended margin of 20% and did not exceed the measurement uncertainty of 17.87% estimated for this type of dosemeters. Tendency of slightly increasing average dose error was observed in every following treatment fraction of the same patient. It was linked to the changes of theoretically estimated dosemeter positions due to the possible patient's organ movement between different treatment fractions, since catheter reconstruction was

  10. Space Shuttle drops down the SAA doses on ISS

    NASA Astrophysics Data System (ADS)

    Dachev, T. P.; Semkova, J.; Tomov, B.; Matviichuk, Yu.; Dimitrov, Pl.; Koleva, R.; Malchev, St.; Reitz, G.; Horneck, G.; De Angelis, G.; Häder, D.-P.; Petrov, V.; Shurshakov, V.; Benghin, V.; Chernykh, I.; Drobyshev, S.; Bankov, N. G.

    2011-06-01

    Long-term analysis of data from two radiation detection instruments on the International Space Station (ISS) shows that the docking of the Space Shuttle drops down the measured dose rates in the region of the South Atlantic Anomaly (SAA) by a factor of 1.5-3. Measurements either by the R3DE detector, which is outside the ISS at the EuTEF facility on the Columbus module behind a shielding of less than 0.45 g cm -2, and by the three detectors of the Liulin-5 particle telescope, which is inside the Russian PEARS module in the spherical tissue equivalent phantom behind much heavier shielding demonstrate that effect. Simultaneously the estimated averaged incident energies of the incoming protons rise up from about 30 to 45 MeV. The effect is explained by the additional shielding against the SAA 30-150 MeV protons, provided by the 78 tons Shuttle to the instruments inside and outside of the ISS. An additional reason is the ISS attitude change (performed for the Shuttle docking) leading to decreasing of dose rates in two of Liulin-5 detectors because of the East-West proton fluxes asymmetry in SAA. The Galactic Cosmic Rays dose rates are practically not affected.

  11. PaxVax CVD 103-HgR single-dose live oral cholera vaccine.

    PubMed

    Levine, Myron M; Chen, Wilbur H; Kaper, James B; Lock, Michael; Danzig, Lisa; Gurwith, Marc

    2017-03-01

    Cholera remains a problem in developing countries and a risk for travelers. Hypochlorhydria, blood group O, cardiac and renal disease increase the risk of developing cholera gravis. Oral vaccines containing inactivated Vibrio cholerae and requiring two doses are available in some countries. No cholera vaccine had been available for U.S. travelers for decades until 2016 when CVD 103-HgR (VAXCHORA™), an oral live attenuated vaccine, was licensed by the U.S. FDA. Areas covered: Enduring protection following wild-type cholera provided the rationale to develop a single-dose live oral vaccine. CVD 103-HgR is well-tolerated and protects against cholera caused by V. cholerae O1 of either serotype (Inaba, Ogawa) and biotype (El Tor, Classical). Since 90% vaccine efficacy is evident 10 days post-ingestion of a single dose, CVD 103-HgR can rapidly protect travelers. Vibriocidal antibody seroconversion correlates with protection; >90% of U.S. adult (including elderly) vaccinees seroconvert. The U.S. Public Health Service's Advisory Committee on Immunization Practices recommends CVD 103-HgR for U.S. travelers to areas of ongoing cholera transmission. Expert commentary: Next steps include evaluations in children, post-licensure safety and effectiveness monitoring, diminishing cold chain constraints, optimizing a 'high-dose' formulation for developing countries, and diminishing/eliminating the need for water to administer a dose.

  12. Proton therapy in clinical practice

    PubMed Central

    Liu, Hui; Chang, Joe Y.

    2011-01-01

    Radiation dose escalation and acceleration improves local control but also increases toxicity. Proton radiation is an emerging therapy for localized cancers that is being sought with increasing frequency by patients. Compared with photon therapy, proton therapy spares more critical structures due to its unique physics. The physical properties of a proton beam make it ideal for clinical applications. By modulating the Bragg peak of protons in energy and time, a conformal radiation dose with or without intensity modulation can be delivered to the target while sparing the surrounding normal tissues. Thus, proton therapy is ideal when organ preservation is a priority. However, protons are more sensitive to organ motion and anatomy changes compared with photons. In this article, we review practical issues of proton therapy, describe its image-guided treatment planning and delivery, discuss clinical outcome for cancer patients, and suggest challenges and the future development of proton therapy. PMID:21527064

  13. Liquid Medication Dosing Errors by Hispanic Parents: Role of Health Literacy and English Proficiency

    PubMed Central

    Harris, Leslie M.; Dreyer, Benard; Mendelsohn, Alan; Bailey, Stacy C.; Sanders, Lee M.; Wolf, Michael S.; Parker, Ruth M.; Patel, Deesha A.; Kim, Kwang Youn A.; Jimenez, Jessica J.; Jacobson, Kara; Smith, Michelle; Yin, H. Shonna

    2016-01-01

    Objective Hispanic parents in the US are disproportionately affected by low health literacy and limited English proficiency (LEP). We examined associations between health literacy, LEP, and liquid medication dosing errors in Hispanic parents. Methods Cross-sectional analysis of data from a multisite randomized controlled experiment to identify best practices for the labeling/dosing of pediatric liquid medications (SAFE Rx for Kids study); 3 urban pediatric clinics. Analyses were limited to Hispanic parents of children <8 years, with health literacy and LEP data (n=1126). Parents were randomized to 5 groups that varied by pairing of units of measurement on the label/dosing tool. Each parent measured 9 doses [3 amounts (2.5,5,7.5 mL) using 3 tools (2 syringes (0.2,0.5 mL increment), 1 cup)] in random order. Dependent variable: Dosing error=>20% dose deviation. Predictor variables: health literacy (Newest Vital Sign) [limited=0–3; adequate=4–6], LEP (speaks English less than “very well”). Results 83.1% made dosing errors (mean(SD) errors/parent=2.2(1.9)). Parents with limited health literacy and LEP had the greatest odds of making a dosing error compared to parents with adequate health literacy who were English proficient (% trials with errors/parent=28.8 vs. 12.9%; AOR=2.2[1.7–2.8]). Parents with limited health literacy who were English proficient were also more likely to make errors (% trials with errors/parent=18.8%; AOR=1.4[1.1–1.9]). Conclusion Dosing errors are common among Hispanic parents; those with both LEP and limited health literacy are at particular risk. Further study is needed to examine how the redesign of medication labels and dosing tools could reduce literacy and language-associated disparities in dosing errors. PMID:28477800

  14. Design of a multicentre randomized controlled trial to assess the safety and efficacy of dose titration by specialized nurses in patients with heart failure. ETIFIC study protocol.

    PubMed

    Oyanguren, Juana; García-Garrido, LLuisa; Nebot Margalef, Magdalena; Lekuona, Iñaki; Comin-Colet, Josep; Manito, Nicolás; Roure, Julia; Ruiz Rodriguez, Pilar; Enjuanes, Cristina; Latorre, Pedro; Torcal Laguna, Jesús; García-Gutiérrez, Susana

    2017-11-01

    Heart failure (HF) is associated with many hospital admissions and relatively high mortality, rates decreasing with administration of beta-blockers (BBs), angiotensin-converting-enzyme inhibitors, angiotensin II receptor blockers, and mineralocorticoid receptor antagonists. The effect is dose dependent, suboptimal doses being common in clinical practice. The 2012 European guidelines recommend close monitoring and dose titration by HF nurses. Our main aim is to compare BB doses achieved by patients after 4 months in intervention (HF nurse-managed) and control (cardiologist-managed) groups. Secondary aims include comparing doses of the other aforementioned drugs achieved after 4 months, adverse events, and outcomes at 6 months in the two groups. We have designed a multicentre (20 hospitals) non-inferiority randomized controlled trial, including patients with new-onset HF, left ventricular ejection fraction ≤40%, and New York Heart Association class II-III, with no contraindications to BBs. We will also conduct qualitative analysis to explore potential barriers to and facilitators of dose titration by HF nurses. In the intervention group, HF nurses will implement titration as prescribed by cardiologists, following a protocol. In controls, cardiologists will both prescribe and titrate doses. The study variables are doses of each of the drugs after 4 months relative to the target dose (%), New York Heart Association class, left ventricular ejection fraction, N-terminal pro B-type natriuretic peptide levels, 6 min walk distance, comorbidities, renal function, readmissions, mortality, quality of life, and psychosocial characteristics. The trial seeks to assess whether titration by HF nurses of drugs recommended in practice guidelines is safe and not inferior to direct management by cardiologists. The results could have an impact on clinical practice. © 2017 The Authors. ESC Heart Failure published by John Wiley & Sons Ltd on behalf of the European Society of

  15. Design of a multicentre randomized controlled trial to assess the safety and efficacy of dose titration by specialized nurses in patients with heart failure. ETIFIC study protocol

    PubMed Central

    García‐Garrido, LLuisa; Nebot Margalef, Magdalena; Lekuona, Iñaki; Comin‐Colet, Josep; Manito, Nicolás; Roure, Julia; Ruiz Rodriguez, Pilar; Enjuanes, Cristina; Latorre, Pedro; Torcal Laguna, Jesús; García‐Gutiérrez, Susana

    2017-01-01

    Abstract Aims Heart failure (HF) is associated with many hospital admissions and relatively high mortality, rates decreasing with administration of beta‐blockers (BBs), angiotensin‐converting‐enzyme inhibitors, angiotensin II receptor blockers, and mineralocorticoid receptor antagonists. The effect is dose dependent, suboptimal doses being common in clinical practice. The 2012 European guidelines recommend close monitoring and dose titration by HF nurses. Our main aim is to compare BB doses achieved by patients after 4 months in intervention (HF nurse‐managed) and control (cardiologist‐managed) groups. Secondary aims include comparing doses of the other aforementioned drugs achieved after 4 months, adverse events, and outcomes at 6 months in the two groups. Methods We have designed a multicentre (20 hospitals) non‐inferiority randomized controlled trial, including patients with new‐onset HF, left ventricular ejection fraction ≤40%, and New York Heart Association class II–III, with no contraindications to BBs. We will also conduct qualitative analysis to explore potential barriers to and facilitators of dose titration by HF nurses. In the intervention group, HF nurses will implement titration as prescribed by cardiologists, following a protocol. In controls, cardiologists will both prescribe and titrate doses. The study variables are doses of each of the drugs after 4 months relative to the target dose (%), New York Heart Association class, left ventricular ejection fraction, N‐terminal pro B‐type natriuretic peptide levels, 6 min walk distance, comorbidities, renal function, readmissions, mortality, quality of life, and psychosocial characteristics. Conclusions The trial seeks to assess whether titration by HF nurses of drugs recommended in practice guidelines is safe and not inferior to direct management by cardiologists. The results could have an impact on clinical practice. PMID:29154427

  16. An alternative arrangement of metered dosing fluid using centrifugal pump

    NASA Astrophysics Data System (ADS)

    Islam, Md. Arafat; Ehsan, Md.

    2017-06-01

    Positive displacement dosing pumps are extensively used in various types of process industries. They are widely used for metering small flow rates of a dosing fluid into a main flow. High head and low controllable flow rates make these pumps suitable for industrial flow metering applications. However their pulsating flow is not very suitable for proper mixing of fluids and they are relatively more expensive to buy and maintain. Considering such problems, alternative techniques to control the fluid flow from a low cost centrifugal pump is practiced. These include - throttling, variable speed drive, impeller geometry control and bypass control. Variable speed drive and impeller geometry control are comparatively costly and the flow control by throttling is not an energy efficient process. In this study an arrangement of metered dosing flow was developed using a typical low cost centrifugal pump using bypass flow technique. Using bypass flow control technique a wide range of metered dosing flows under a range of heads were attained using fixed pump geometry and drive speed. The bulk flow returning from the system into the main tank ensures better mixing which may eliminate the need of separate agitators. Comparative performance study was made between the bypass flow control arrangement of centrifugal pump and a diaphragm type dosing pump. Similar heads and flow rates were attainable using the bypass control system compared to the diaphragm dosing pump, but using relatively more energy. Geometrical optimization of the centrifugal pump impeller was further carried out to make the bypass flow arrangement more energy efficient. Although both the systems run at low overall efficiencies but the capital cost could be reduced by about 87% compared to the dosing pump. The savings in capital investment and lower maintenance cost very significantly exceeds the relatively higher energy cost of the bypass system. This technique can be used as a cost effective solution for

  17. Implementation of protocolized tight control and biological dose optimization in daily clinical practice: results of a pilot study.

    PubMed

    Lesuis, N; Verhoef, L M; Nieboer, L M; Bruyn, G A; Baudoin, P; van Vollenhoven, R F; Hulscher, Mejl; van den Hoogen, Fhj; den Broeder, A A

    2017-03-01

    To assess the effects of education, guideline development, and individualized treatment advice on rheumatologist adherence to tight control-based treatment and biological dose optimization in rheumatoid arthritis (RA), psoriatic arthritis (PsA), and spondyloarthropathy (SpA) patients. This pilot study, among two rheumatologists and two specialized nurses in a general hospital, combined education, feedback, local guideline development, and individualized treatment advice. Outcomes (baseline and 1 year post-intervention) were the percentage of patients with a Disease Activity Score in 28 joints (DAS28) or Bath Ankylosing Spondylitis Disease Activity Index (BASDAI) measured during the visit, mean DAS28/BASDAI, and the percentage of patients using a reduced biological dose. DAS28 outcomes only applied to RA and PsA patients, BASDAI outcomes only applied to SpA patients whereas outcomes on biological dose applied to all patients. A total of 232 patients (67% RA, 15% PsA, 18% SpA; 58% female, mean age 56 ± 15 years) were included in the study. The percentage of DAS28 and BASDAI measurements performed increased after the intervention [DAS28 15-51%, odds ratio (OR) 3.3, 95% confidence interval (CI) 2.1-5.5; BASDAI 23-50%, OR 2.2, 95% CI 1.0-5.5], with mean DAS28 and BASDAI scores remaining similar (DAS28: mean difference 0.1, 95% CI -0.3 to 0.5; BASDAI: mean difference 0.03, 95% CI -1.8 to 1.9). Use of a reduced biological dose increased from 10% to 61% (OR 3.9, 95% CI 2.4-6.5). A multicomponent intervention strategy aimed at rheumatologists can lead to improved adherence to tight control-based treatment and a reduction in the use of biologicals in RA, SpA, and PsA patients.

  18. Dosimetric quality endpoints for low-dose-rate prostate brachytherapy using biological effective dose (bed) vs. conventional dose

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Singh, Rachana; Al-Hallaq, Hania; Pelizzari, Charles A.

    2003-12-31

    The purpose of this study was to compare conventional low-dose-rate prostate brachytherapy dosimetric quality parameters with their biological effective dose (BED) counterparts. To validate a model for transformation from conventional dose to BED, the postimplant plans of 31 prostate brachytherapy patients were evaluated using conventional dose-volume histogram (DVH) quality endpoints and analogous BED-DVH endpoints. Based on CT scans obtained 4 weeks after implantation, DVHs were computed and standard dosimetric endpoints V100 (volume receiving 100% of the prescribed dose), V150, V200, HI (1-[V150/V100]), and D90 (dose that 90% of the target volume received) were obtained for quality analysis. Using known andmore » reported transformations, dose grids were transformed to BED-early ({alpha}/{beta} = 10 Gy) and BED-late ({alpha}/{beta} = 3 Gy) grids, and the same dosimetric endpoints were analyzed. For conventional, BED-early and BED-late DVHs, no differences in V100 were seen (0.896, 0.893, and 0.894, respectively). However, V150 and V200 were significantly higher for both BED-early (0.582 and 0.316) and BED-late (0.595 and 0.337), compared with the conventional (0.539 and 0.255) DVHs. D90 was significantly lower for the BED-early (103.1 Gy) and BED-late transformations (106.9 Gy) as compared with the conventional (119.5 Gy) DVHs. The conventional prescription parameter V100 is the same for the corresponding BED-early and BED-late transformed DVHs. The toxicity parameters V150 and V200 are slightly higher using the BED transformations, suggesting that the BED doses are somewhat higher than predicted using conventional DVHs. The prescription/quality parameter D90 is slightly lower, implying that target coverage is lower than predicted using conventional DVHs. This methodology can be applied to analyze BED dosimetric endpoints to improve clinical outcome and reduce complications of prostate brachytherapy.« less

  19. A deterministic partial differential equation model for dose calculation in electron radiotherapy.

    PubMed

    Duclous, R; Dubroca, B; Frank, M

    2010-07-07

    High-energy ionizing radiation is a prominent modality for the treatment of many cancers. The approaches to electron dose calculation can be categorized into semi-empirical models (e.g. Fermi-Eyges, convolution-superposition) and probabilistic methods (e.g.Monte Carlo). A third approach to dose calculation has only recently attracted attention in the medical physics community. This approach is based on the deterministic kinetic equations of radiative transfer. We derive a macroscopic partial differential equation model for electron transport in tissue. This model involves an angular closure in the phase space. It is exact for the free streaming and the isotropic regime. We solve it numerically by a newly developed HLLC scheme based on Berthon et al (2007 J. Sci. Comput. 31 347-89) that exactly preserves the key properties of the analytical solution on the discrete level. We discuss several test cases taken from the medical physics literature. A test case with an academic Henyey-Greenstein scattering kernel is considered. We compare our model to a benchmark discrete ordinate solution. A simplified model of electron interactions with tissue is employed to compute the dose of an electron beam in a water phantom, and a case of irradiation of the vertebral column. Here our model is compared to the PENELOPE Monte Carlo code. In the academic example, the fluences computed with the new model and a benchmark result differ by less than 1%. The depths at half maximum differ by less than 0.6%. In the two comparisons with Monte Carlo, our model gives qualitatively reasonable dose distributions. Due to the crude interaction model, these so far do not have the accuracy needed in clinical practice. However, the new model has a computational cost that is less than one-tenth of the cost of a Monte Carlo simulation. In addition, simulations can be set up in a similar way as a Monte Carlo simulation. If more detailed effects such as coupled electron-photon transport, bremsstrahlung

  20. A deterministic partial differential equation model for dose calculation in electron radiotherapy

    NASA Astrophysics Data System (ADS)

    Duclous, R.; Dubroca, B.; Frank, M.

    2010-07-01

    High-energy ionizing radiation is a prominent modality for the treatment of many cancers. The approaches to electron dose calculation can be categorized into semi-empirical models (e.g. Fermi-Eyges, convolution-superposition) and probabilistic methods (e.g. Monte Carlo). A third approach to dose calculation has only recently attracted attention in the medical physics community. This approach is based on the deterministic kinetic equations of radiative transfer. We derive a macroscopic partial differential equation model for electron transport in tissue. This model involves an angular closure in the phase space. It is exact for the free streaming and the isotropic regime. We solve it numerically by a newly developed HLLC scheme based on Berthon et al (2007 J. Sci. Comput. 31 347-89) that exactly preserves the key properties of the analytical solution on the discrete level. We discuss several test cases taken from the medical physics literature. A test case with an academic Henyey-Greenstein scattering kernel is considered. We compare our model to a benchmark discrete ordinate solution. A simplified model of electron interactions with tissue is employed to compute the dose of an electron beam in a water phantom, and a case of irradiation of the vertebral column. Here our model is compared to the PENELOPE Monte Carlo code. In the academic example, the fluences computed with the new model and a benchmark result differ by less than 1%. The depths at half maximum differ by less than 0.6%. In the two comparisons with Monte Carlo, our model gives qualitatively reasonable dose distributions. Due to the crude interaction model, these so far do not have the accuracy needed in clinical practice. However, the new model has a computational cost that is less than one-tenth of the cost of a Monte Carlo simulation. In addition, simulations can be set up in a similar way as a Monte Carlo simulation. If more detailed effects such as coupled electron-photon transport, bremsstrahlung

  1. Neutron dose equivalent meter

    DOEpatents

    Olsher, Richard H.; Hsu, Hsiao-Hua; Casson, William H.; Vasilik, Dennis G.; Kleck, Jeffrey H.; Beverding, Anthony

    1996-01-01

    A neutron dose equivalent detector for measuring neutron dose capable of accurately responding to neutron energies according to published fluence to dose curves. The neutron dose equivalent meter has an inner sphere of polyethylene, with a middle shell overlying the inner sphere, the middle shell comprising RTV.RTM. silicone (organosiloxane) loaded with boron. An outer shell overlies the middle shell and comprises polyethylene loaded with tungsten. The neutron dose equivalent meter defines a channel through the outer shell, the middle shell, and the inner sphere for accepting a neutron counter tube. The outer shell is loaded with tungsten to provide neutron generation, increasing the neutron dose equivalent meter's response sensitivity above 8 MeV.

  2. LETTER TO THE EDITOR: Response to 'Patient dose measurements in radiological practices'

    NASA Astrophysics Data System (ADS)

    Zoetelief, J.; Wambersie, A.

    2006-06-01

    A lack of suitable dosimetric quantities for application in diagnostic radiology is noted by Dr Moores. It is concluded by Dr Moores that it is not possible to adhere to the basic principles of the International Commission on Radiation Units and Measurements (ICRU) regarding patient dosimetry in diagnostic radiology due to the extremely wide variety of quantities and units employed. The conclusion of the ICRU on similar observations, however, was that there is a need for harmonization of quantities and terminology for dosimetry in diagnostic and interventional radiology and they established a Report Committee with the aim of formulating an ICRU report on 'dosimetric procedures in diagnostic radiology'. The report produced by this committee entitled 'Patient dosimetry for x rays used in medical imaging' was accepted for publication in December 2005 and is currently at press, and may serve to improve the current situation with regard to patient dose measurement in diagnostic and interventional radiology.

  3. Modelling PK/QT relationships from Phase I dose-escalation trials for drug combinations and developing quantitative risk assessments of clinically relevant QT prolongations.

    PubMed

    Sinclair, Karen; Kinable, Els; Grosch, Kai; Wang, Jixian

    2016-05-01

    In current industry practice, it is difficult to assess QT effects at potential therapeutic doses based on Phase I dose-escalation trials in oncology due to data scarcity, particularly in combinations trials. In this paper, we propose to use dose-concentration and concentration-QT models jointly to model the exposures and effects of multiple drugs in combination. The fitted models then can be used to make early predictions for QT prolongation to aid choosing recommended dose combinations for further investigation. The models consider potential correlation between concentrations of test drugs and potential drug-drug interactions at PK and QT levels. In addition, this approach allows for the assessment of the probability of QT prolongation exceeding given thresholds of clinical significance. The performance of this approach was examined via simulation under practical scenarios for dose-escalation trials for a combination of two drugs. The simulation results show that invaluable information of QT effects at therapeutic dose combinations can be gained by the proposed approaches. Early detection of dose combinations with substantial QT prolongation is evaluated effectively through the CIs of the predicted peak QT prolongation at each dose combination. Furthermore, the probability of QT prolongation exceeding a certain threshold is also computed to support early detection of safety signals while accounting for uncertainty associated with data from Phase I studies. While the prediction of QT effects is sensitive to the dose escalation process, the sensitivity and limited sample size should be considered when providing support to the decision-making process for further developing certain dose combinations. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  4. High-dose Versus Low-dose Tranexamic Acid to Reduce Transfusion Requirements in Pediatric Scoliosis Surgery.

    PubMed

    Johnson, Daniel J; Johnson, Christine C; Goobie, Susan M; Nami, Nina; Wetzler, Joshua A; Sponseller, Paul D; Frank, Steven M

    2017-12-01

    Our objective was to quantify blood loss and transfusion requirements for high-dose and low-dose tranexamic acid (TXA) dosing regimens in pediatric patients undergoing spinal fusion for correction of idiopathic scoliosis. Previous investigators have established the efficacy of TXA in pediatric scoliosis surgery; however, the dosing regimens vary widely and the optimal dose has not been established. We retrospectively analyzed electronic medical records for 116 patients who underwent spinal fusion surgery for idiopathic scoliosis by a single surgeon and were treated with TXA. In total, 72 patients received a 10 mg/kg loading dose with a 1 mg/kg/h maintenance dose (low-dose) and 44 patients received 50 mg/kg loading dose with a 5 mg/kg/h maintenance dose (high-dose). Estimated blood loss and transfusion requirements were compared between dosing groups. Patient characteristics were nearly identical between the 2 groups. Compared with the low-dose TXA group, the high-dose TXA group had decreased estimated blood loss (695 vs. 968 mL, P=0.01), and a decrease in both intraoperative (0.3 vs. 0.9 units, P=0.01) and whole hospitalization (0.4 vs. 1.0 units, P=0.04) red blood cell transfusion requirements. The higher-dose TXA was associated with decreased intraoperative (P=0.01), and whole hospital transfusion (P=0.01) requirements, even after risk-adjustment for potential confounding variables. High-dose TXA is more effective than low-dose TXA in reducing blood loss and transfusion requirements in pediatric idiopathic scoliosis patients undergoing surgery. Level-III, retrospective cohort study.

  5. VMAT linear accelerator commissioning and quality assurance: dose control and gantry speed tests

    PubMed Central

    Rowshanfarzad, Pejman; Greer, Peter B.

    2016-01-01

    In VMAT treatment delivery the ability of the linear accelerator (linac) to accurately control dose versus gantry angle is critical to delivering the plan correctly. A new VMAT test delivery was developed to specifically test the dose versus gantry angle with the full range of allowed gantry speeds and dose rates. The gantry‐mounted IBA MatriXX with attached inclinometer was used in movie mode to measure the instantaneous relative dose versus gantry angle during the plan every 0.54 s. The results were compared to the expected relative dose at each gantry angle calculated from the plan. The same dataset was also used to compare the instantaneous gantry speeds throughout the delivery compared to the expected gantry speeds from the plan. Measurements performed across four linacs generally show agreement between measurement and plan to within 1.5% in the constant dose rate regions and dose rate modulation within 0.1 s of the plan. Instantaneous gantry speed was measured to be within 0.11∘/s of the plan (1 SD). An error in one linac was detected in that the nominal gantry speed was incorrectly calibrated. This test provides a practical method to quality‐assure critical aspects of VMAT delivery including dose versus gantry angle and gantry speed control. The method can be performed with any detector that can acquire time‐resolved dosimetric information that can be synchronized with a measurement of gantry angle. The test fulfils several of the aims of the recent Netherlands Commission on Radiation Dosimetry (NCS) Report 24, which provides recommendations for comprehensive VMAT quality assurance. PACS number(s): 87.55.Qr PMID:27167282

  6. Switching From Age-Based Stimulus Dosing to Dose Titration Protocols in Electroconvulsive Therapy: Empirical Evidence for Better Patient Outcomes With Lower Peak and Cumulative Energy Doses.

    PubMed

    O'Neill-Kerr, Alex; Yassin, Anhar; Rogers, Stephen; Cornish, Janie

    2017-09-01

    The aim of this study was to test the proposition that adoption of a dose titration protocol may be associated with better patient outcomes, at lower treatment dose, and with comparable cumulative dose to that in patients treated using an age-based stimulus dosing protocol. This was an analysis of data assembled from archived records and based on cohorts of patients treated respectively on an age-based stimulus dosing protocol and on a dose titration protocol in the National Health Service in England. We demonstrated a significantly better response in the patient cohort treated with dose titration than with age-based stimulus dosing. Peak doses were less and the total cumulative dose was less in the dose titration group than in the age-based stimulus dosing group. Our findings are consistent with superior outcomes in patients treated using a dose titration protocol when compared with age-based stimulus dosing in a similar cohort of patients.

  7. Current worldwide nuclear cardiology practices and radiation exposure: results from the 65 country IAEA Nuclear Cardiology Protocols Cross-Sectional Study (INCAPS)

    PubMed Central

    Einstein, Andrew J.; Pascual, Thomas N. B.; Mercuri, Mathew; Karthikeyan, Ganesan; Vitola, João V.; Mahmarian, John J.; Better, Nathan; Bouyoucef, Salah E.; Hee-Seung Bom, Henry; Lele, Vikram; Magboo, V. Peter C.; Alexánderson, Erick; Allam, Adel H.; Al-Mallah, Mouaz H.; Flotats, Albert; Jerome, Scott; Kaufmann, Philipp A.; Luxenburg, Osnat; Shaw, Leslee J.; Underwood, S. Richard; Rehani, Madan M.; Kashyap, Ravi; Paez, Diana; Dondi, Maurizio

    2015-01-01

    Aims To characterize patient radiation doses from nuclear myocardial perfusion imaging (MPI) and the use of radiation-optimizing ‘best practices’ worldwide, and to evaluate the relationship between laboratory use of best practices and patient radiation dose. Methods and results We conducted an observational cross-sectional study of protocols used for all 7911 MPI studies performed in 308 nuclear cardiology laboratories in 65 countries for a single week in March–April 2013. Eight ‘best practices’ relating to radiation exposure were identified a priori by an expert committee, and a radiation-related quality index (QI) devised indicating the number of best practices used by a laboratory. Patient radiation effective dose (ED) ranged between 0.8 and 35.6 mSv (median 10.0 mSv). Average laboratory ED ranged from 2.2 to 24.4 mSv (median 10.4 mSv); only 91 (30%) laboratories achieved the median ED ≤ 9 mSv recommended by guidelines. Laboratory QIs ranged from 2 to 8 (median 5). Both ED and QI differed significantly between laboratories, countries, and world regions. The lowest median ED (8.0 mSv), in Europe, coincided with high best-practice adherence (mean laboratory QI 6.2). The highest doses (median 12.1 mSv) and low QI (4.9) occurred in Latin America. In hierarchical regression modelling, patients undergoing MPI at laboratories following more ‘best practices’ had lower EDs. Conclusion Marked worldwide variation exists in radiation safety practices pertaining to MPI, with targeted EDs currently achieved in a minority of laboratories. The significant relationship between best-practice implementation and lower doses indicates numerous opportunities to reduce radiation exposure from MPI globally. PMID:25898845

  8. Evaluating the accuracy of technicians and pharmacists in checking unit dose medication cassettes.

    PubMed

    Ambrose, Peter J; Saya, Frank G; Lovett, Larry T; Tan, Sandy; Adams, Dale W; Shane, Rita

    2002-06-15

    The accuracy rates of board-registered pharmacy technicians and pharmacists in checking unit dose medication cassettes in the inpatient setting at two separate institutions were examined. Cedars-Sinai Medical Center and Long Beach Memorial Medical Center, both in Los Angeles county, petitioned the California State Board of Pharmacy to approve a waiver of the California Code of Regulations to conduct an experimental program to compare the accuracy of unit dose medication cassettes checked by pharmacists with that of cassettes checked by trained, certified pharmacy technicians. The study consisted of three parts: assessing pharmacist baseline checking accuracy (Phase I), developing a technician-training program and certifying technicians who completed the didactic and practical training (Phase II), and evaluating the accuracy of certified technicians checking unit dose medication cassettes as a daily function (Phase III). Twenty-nine pharmacists and 41 technicians (3 of whom were pharmacy interns) participated in the study. Of the technicians, all 41 successfully completed the didactic and practical training, 39 successfully completed the audits and became certified checkers, and 2 (including 1 of the interns) did not complete the certification audits because they were reassigned to another work area or had resigned. In Phase II, the observed accuracy rate and its lower confidence limit exceeded the predetermined minimum requirement of 99.8% for a certified checker. The mean accuracy rates for technicians were identical at the two institutions (p = 1.0). The difference in mean accuracy rates between pharmacists (99.52%; 95% confidence interval [CI] 99.44-99.58%) and technicians, (99.89%; 95% CI 99.87-99.90%) was significant (p < 0.0001). Inpatient technicians who had been trained and certified in a closely supervised program that incorporated quality assurance mechanisms could safely and accurately check unit dose medication cassettes filled by other technicians.

  9. Opioid needs of patients with advanced cancer and the morphine dose-limiting law in Egypt.

    PubMed

    Alsirafy, Samy A; El-Mesidi, Salah M; El-Sherief, Wesam A; Galal, Khaled M; Abou-Elela, Enas N; Aklan, Nahla A

    2011-01-01

    Morphine is the drug of choice for moderate to severe cancer pain management. The Egyptian Narcotics Control Law limits the amount of morphine prescribed in a single prescription to a maximum of 420 mg for tablets and 60 mg for ampoules. The usual practice in Egypt is to provide that limited amount of morphine on a weekly basis. The aim of this study is to estimate the extent to which Egyptian patients may be undertreated because of this law. We reviewed the medical records of advanced cancer patients referred to the first palliative care unit in Egypt over a seven-month period. Cancer pain was managed following the WHO guidelines. After modifying the internal institutional policy, patients received adequate amounts of the available opioids without any violations of the law. From 117 eligible advanced cancer patients, 58 (50%) patients required strong opioids, 32 (27%) required weak opioids, and 27 (23%) required no regular opioids. The mean last prescribed opioid dose for those who required strong opioids was 194 mg of oral morphine equivalent/24 h (± 180). For this group of patients, a single weekly prescription would supply enough oral morphine for only 26% of them. In the case of parenteral morphine, none of these patients would receive an adequate supply. In view of the current morphine dose-limiting law and practices in Egypt, the majority of patients suffering severe cancer pain would not have access to adequate morphine doses. That dose-limiting law and other restrictive regulations represent an obstacle to cancer pain control in Egypt and should be revised urgently.

  10. Low dose rate brachytherapy (LDR-BT) as monotherapy for early stage prostate cancer in Italy: practice and outcome analysis in a series of 2237 patients from 11 institutions

    PubMed Central

    Fellin, Giovanni; Mirri, Maria A; Santoro, Luigi; Divan, Claudio; Mussari, Salvatore; Ziglio, Francesco; La Face, Beniamino; Barbera, Fernando; Buglione, Michela; Bandera, Laura; Ghedi, Barbara; Di Muzio, Nadia G; Losa, Andrea; Mangili, Paola; Nava, Luciano; Chiarlone, Renato; Ciscognetti, Nunzia; Gastaldi, Emilio; Cattani, Federica; Spoto, Ruggero; Vavassori, Andrea; Giglioli, Francesca R; Guarneri, Alessia; Cerboneschi, Valentina; Mignogna, Marcello; Paoluzzi, Mauro; Ravaglia, Valentina; Chiumento, Costanza; Clemente, Stefania; Fusco, Vincenzo; Santini, Roberto; Stefanacci, Marco; Mangiacotti, Francesco P; Martini, Marco; Palloni, Tiziana; Schinaia, Giuseppe; Lazzari, Grazia; Silvano, Giovanni; Magrini, Stefano; Ricardi, Umberto; Santoni, Riccardo; Orecchia, Roberto

    2016-01-01

    Objective: Low-dose-rate brachytherapy (LDR-BT) in localized prostate cancer is available since 15 years in Italy. We realized the first national multicentre and multidisciplinary data collection to evaluate LDR-BT practice, given as monotherapy, and outcome in terms of biochemical failure. Methods: Between May 1998 and December 2011, 2237 patients with early-stage prostate cancer from 11 Italian community and academic hospitals were treated with iodine-125 (125I) or palladium-103 LDR-BT as monotherapy and followed up for at least 2 years. 125I seeds were implanted in 97.7% of the patients: the mean dose received by 90% of target volume was 145 Gy; the mean target volume receiving 100% of prescribed dose (V100) was 91.1%. Biochemical failure-free survival (BFFS), disease-specific survival (DSS) and overall survival (OS) were estimated using Kaplan–Meier method. Log-rank test and multivariable Cox regression were used to evaluate the relationship of covariates with outcomes. Results: Median follow-up time was 65 months. 5- and 7-year DSS, OS and BFFS were 99 and 98%, 94 and 89%, and 92 and 88%, respectively. At multivariate analysis, the National Comprehensive Cancer Network score (p < 0.0001) and V100 (p = 0.09) were correlated with BFFS, with V100 effect significantly different between patients at low risk and those at intermediate/high risk (p = 0.04). Short follow-up and lack of toxicity data represent the main limitations for a global evaluation of LDR-BT. Conclusion: This first multicentre Italian report confirms LDR-BT as an excellent curative modality for low-/intermediate-risk prostate cancer. Advances in knowledge: Multidisciplinary teams may help to select adequately patients to be treated with brachytherapy, with a direct impact on the implant quality and, possibly, on outcome. PMID:27384381

  11. Low dose rate brachytherapy (LDR-BT) as monotherapy for early stage prostate cancer in Italy: practice and outcome analysis in a series of 2237 patients from 11 institutions.

    PubMed

    Fellin, Giovanni; Mirri, Maria A; Santoro, Luigi; Jereczek-Fossa, Barbara A; Divan, Claudio; Mussari, Salvatore; Ziglio, Francesco; La Face, Beniamino; Barbera, Fernando; Buglione, Michela; Bandera, Laura; Ghedi, Barbara; Di Muzio, Nadia G; Losa, Andrea; Mangili, Paola; Nava, Luciano; Chiarlone, Renato; Ciscognetti, Nunzia; Gastaldi, Emilio; Cattani, Federica; Spoto, Ruggero; Vavassori, Andrea; Giglioli, Francesca R; Guarneri, Alessia; Cerboneschi, Valentina; Mignogna, Marcello; Paoluzzi, Mauro; Ravaglia, Valentina; Chiumento, Costanza; Clemente, Stefania; Fusco, Vincenzo; Santini, Roberto; Stefanacci, Marco; Mangiacotti, Francesco P; Martini, Marco; Palloni, Tiziana; Schinaia, Giuseppe; Lazzari, Grazia; Silvano, Giovanni; Magrini, Stefano; Ricardi, Umberto; Santoni, Riccardo; Orecchia, Roberto

    2016-09-01

    Low-dose-rate brachytherapy (LDR-BT) in localized prostate cancer is available since 15 years in Italy. We realized the first national multicentre and multidisciplinary data collection to evaluate LDR-BT practice, given as monotherapy, and outcome in terms of biochemical failure. Between May 1998 and December 2011, 2237 patients with early-stage prostate cancer from 11 Italian community and academic hospitals were treated with iodine-125 ((125)I) or palladium-103 LDR-BT as monotherapy and followed up for at least 2 years. (125)I seeds were implanted in 97.7% of the patients: the mean dose received by 90% of target volume was 145 Gy; the mean target volume receiving 100% of prescribed dose (V100) was 91.1%. Biochemical failure-free survival (BFFS), disease-specific survival (DSS) and overall survival (OS) were estimated using Kaplan-Meier method. Log-rank test and multivariable Cox regression were used to evaluate the relationship of covariates with outcomes. Median follow-up time was 65 months. 5- and 7-year DSS, OS and BFFS were 99 and 98%, 94 and 89%, and 92 and 88%, respectively. At multivariate analysis, the National Comprehensive Cancer Network score (p < 0.0001) and V100 (p = 0.09) were correlated with BFFS, with V100 effect significantly different between patients at low risk and those at intermediate/high risk (p = 0.04). Short follow-up and lack of toxicity data represent the main limitations for a global evaluation of LDR-BT. This first multicentre Italian report confirms LDR-BT as an excellent curative modality for low-/intermediate-risk prostate cancer. Multidisciplinary teams may help to select adequately patients to be treated with brachytherapy, with a direct impact on the implant quality and, possibly, on outcome.

  12. Single-Dose and Multiple-Dose Pharmacokinetics of Nicotine 6 mg Gum.

    PubMed

    Hansson, Anna; Rasmussen, Thomas; Kraiczi, Holger

    2017-04-01

    Under-dosing is a recognized problem with current nicotine replacement therapy (NRT). Therefore, a new 6mg nicotine gum has been developed. To compare the nicotine uptake from the 6mg gum versus currently available NRT products, two pharmacokinetic studies were performed. In one randomized crossover study, 44 healthy adult smokers received single doses of 6, 4, and 2mg nicotine gum, and 4mg nicotine lozenge on separate occasions. In a separate randomized crossover multiple-dose study over 11 hours, 50 healthy adult smokers received one 6mg gum every hour and 90 minutes, respectively, one 4mg gum every hour, and one 4mg lozenge every hour. In both studies, blood samples were collected over 12 hours to determine single-dose and multiple-dose pharmacokinetic variables. In the single-dose study, the amount of nicotine released from the 2, 4, and 6mg gums (1.44, 3.36, and 4.94mg) as well as the resulting maximum concentration and area under the curve (5.9, 10.1, and 13.8ng/mL, and 17.1, 30.7, 46.2ng/mL × h, respectively) increased with dose. The maximum concentration and area under the curve of the 6mg gum were 44% and 30% greater, respectively, than those for 4mg lozenge. Upon hourly administration, the steady-state average plasma nicotine concentration with 6mg gum (37.4ng/mL) was significantly higher than those for 4mg lozenge (28.3ng/mL) and 4mg gum (27.1ng/mL). Nicotine delivery via the 6mg gum results in higher plasma nicotine concentrations after a single dose and at steady state than with currently available oral NRT. Under-dosing is a recognized problem with current NRT. Therefore, a new 6mg nicotine gum has been developed. Our studies show that upon single-dose and multiple-dose administration, the 6mg gum releases and delivers more nicotine to the systemic circulation than 2mg gum, 4mg gum, and 4mg lozenge. Thus, each 6mg nicotine gum provides a higher degree of nicotine substitution and/or lasts for a longer period of time than currently available nicotine

  13. Parotid gland mean dose as a xerostomia predictor in low-dose domains.

    PubMed

    Gabryś, Hubert Szymon; Buettner, Florian; Sterzing, Florian; Hauswald, Henrik; Bangert, Mark

    2017-09-01

    Xerostomia is a common side effect of radiotherapy resulting from excessive irradiation of salivary glands. Typically, xerostomia is modeled by the mean dose-response characteristic of parotid glands and prevented by mean dose constraints to either contralateral or both parotid glands. The aim of this study was to investigate whether normal tissue complication probability (NTCP) models based on the mean radiation dose to parotid glands are suitable for the prediction of xerostomia in a highly conformal low-dose regime of modern intensity-modulated radiotherapy (IMRT) techniques. We present a retrospective analysis of 153 head and neck cancer patients treated with radiotherapy. The Lyman Kutcher Burman (LKB) model was used to evaluate predictive power of the parotid gland mean dose with respect to xerostomia at 6 and 12 months after the treatment. The predictive performance of the model was evaluated by receiver operating characteristic (ROC) curves and precision-recall (PR) curves. Average mean doses to ipsilateral and contralateral parotid glands were 25.4 Gy and 18.7 Gy, respectively. QUANTEC constraints were met in 74% of patients. Mild to severe (G1+) xerostomia prevalence at both 6 and 12 months was 67%. Moderate to severe (G2+) xerostomia prevalence at 6 and 12 months was 20% and 15%, respectively. G1 + xerostomia was predicted reasonably well with area under the ROC curve ranging from 0.69 to 0.76. The LKB model failed to provide reliable G2 + xerostomia predictions at both time points. Reduction of the mean dose to parotid glands below QUANTEC guidelines resulted in low G2 + xerostomia rates. In this dose domain, the mean dose models predicted G1 + xerostomia fairly well, however, failed to recognize patients at risk of G2 + xerostomia. There is a need for the development of more flexible models able to capture complexity of dose response in this dose regime.

  14. QMRA for Drinking Water: 2. The Effect of Pathogen Clustering in Single-Hit Dose-Response Models.

    PubMed

    Nilsen, Vegard; Wyller, John

    2016-01-01

    Spatial and/or temporal clustering of pathogens will invalidate the commonly used assumption of Poisson-distributed pathogen counts (doses) in quantitative microbial risk assessment. In this work, the theoretically predicted effect of spatial clustering in conventional "single-hit" dose-response models is investigated by employing the stuttering Poisson distribution, a very general family of count distributions that naturally models pathogen clustering and contains the Poisson and negative binomial distributions as special cases. The analysis is facilitated by formulating the dose-response models in terms of probability generating functions. It is shown formally that the theoretical single-hit risk obtained with a stuttering Poisson distribution is lower than that obtained with a Poisson distribution, assuming identical mean doses. A similar result holds for mixed Poisson distributions. Numerical examples indicate that the theoretical single-hit risk is fairly insensitive to moderate clustering, though the effect tends to be more pronounced for low mean doses. Furthermore, using Jensen's inequality, an upper bound on risk is derived that tends to better approximate the exact theoretical single-hit risk for highly overdispersed dose distributions. The bound holds with any dose distribution (characterized by its mean and zero inflation index) and any conditional dose-response model that is concave in the dose variable. Its application is exemplified with published data from Norovirus feeding trials, for which some of the administered doses were prepared from an inoculum of aggregated viruses. The potential implications of clustering for dose-response assessment as well as practical risk characterization are discussed. © 2016 Society for Risk Analysis.

  15. Radiation-hard erbium optical fiber and fiber amplifier for both low- and high-dose space missions.

    PubMed

    Girard, S; Laurent, A; Pinsard, E; Robin, T; Cadier, B; Boutillier, M; Marcandella, C; Boukenter, A; Ouerdane, Y

    2014-05-01

    We present a new structure for erbium-doped optical fibers [hole-assisted carbon-coated, (HACC)] that, combined with an appropriate choice of codopants in the core, strongly enhances their radiation tolerance. We built an erbium-doped fiber amplifier based on this HACC fiber and characterize its degradation under γ-ray doses up to 315 krad (SiO2) in the ON mode. The 31 dB amplifier is practically radiation insensitive, with a gain change of merely -2.2×10(-3) dB/krad. These performances authorize the use of HACC doped fibers and amplifiers for various applications in environments associated with today's missions (of doses up to 50 krad) and even for future space missions associated with higher dose constraints.

  16. [Absorbed dose and the effective dose of panoramic temporo mandibular joint radiography].

    PubMed

    Matsuo, Ayae; Okano, Tsuneichi; Gotoh, Kenichi; Yokoi, Midori; Hirukawa, Akiko; Okumura, Shinji; Koyama, Syuji

    2011-01-01

    This study measured the radiation doses absorbed by the patient during Panoramic temporo mandibular joint radiography (Panoramic TMJ), Schüllers method and Orbitoramus projection. The dose of the frontal view in Panoramic TMJ was compared to that with Orbitoramus projection and the lateral view in Panoramic TMJ was compared to that with Schüllers method. We measured the doses received by various organs and calculated the effective doses using the guidelines of the International Commission on Radiological Protection in Publication 103. Organ absorbed doses were measured using an anthropomorphic phantom, loaded with thermoluminescent dosimeters (TLD), located at 160 sensitive sites. The dose shows the sum value of irradiation on both the right and left sides. In addition, we set a few different exposure field sizes. The effective dose for a frontal view in Panoramic TMJ was 11 µSv, and that for the lateral view was 14 µSv. The lens of the Orbitoramus projection was 40 times higher than the frontal view in Panoramic TMJ. Although the effective dose of the lateral view in Panoramic TMJ was 3 times higher than that of the small exposure field (10×10 cm on film) in Schüller's method, it was the same as that of a mid-sized exposure field. When the exposure field in the inferior 1/3 was reduced during panoramic TMJ, the effective doses could be decreased. Therefore we recommend that the size of the exposure field in Panoramic TMJ be decreased.

  17. Do Asian renal transplant patients need another mycophenolate mofetil dose compared with Caucasian or African American patients?

    PubMed

    Li, Pengmei; Shuker, Nauras; Hesselink, Dennis A; van Schaik, Ron H N; Zhang, Xianglin; van Gelder, Teun

    2014-10-01

    Mycophenolate mofetil (MMF) is used to prevent acute rejection following solid organ transplantation in transplant centers all over the world. Patients from different ethnic backgrounds are treated with this drug, for which therapeutic drug monitoring (TDM) has not become the standard of practice in most centers. Whether or not some ethnic groups require a different MMF dose has been a topic of debate in recent years. In this review, it is shown that Asian patients, compared with Caucasian patients, with a comparable MMF dose reach higher mycophenolic acid (MPA) exposure. Also clinical experience points toward more adverse events in case of treatment with 1 g MMF bid in Asian patients, and therefore, for this ethnic group, a lower maintenance dose seems justified. In contrast, African American patients reach similar drug concentrations as Caucasians patients receiving the same MMF dose, but due to immunological reasons, they require a higher MMF dose to reach comparable acute rejection incidences. When TDM is performed, clinicians can correct the dose and compensate for interethnic differences in drug exposure. Otherwise, it is important to choose the right dose. This optimal dose is 20-46% lower in Asian transplant recipients than in Caucasian or African American patients. © 2014 Steunstichting ESOT.

  18. A simplified approach for exit dose in vivo measurements in radiotherapy and its clinical application.

    PubMed

    Banjade, D P; Shrestha, S L; Shukri, A; Tajuddin, A A; Bhat, M

    2002-09-01

    This is a study using LiF:Mg;Ti thermoluminescent dosimeter (TLD) rods in phantoms to investigate the effect of lack of backscatter on exit dose. Comparing the measured dose with anticipated dose calculated using tissue maximum ratio (TMR) or percentage depth dose (PDD) gives rise to a correction factor. This correction factor may be applied to in-vivo dosimetry results to derive true dose to a point within the patient. Measurements in a specially designed humanoid breast phantom as well as patients undergoing radiotherapy treatment were also been done. TLDs with reproducibility of within +/- 3% (1 SD) are irradiated in a series of measurements for 6 and 10 MV photon beams from a medical linear accelerator. The measured exit doses for the different phantom thickness for 6 MV beams are found to be lowered by 10.9 to 14.0% compared to the dose derived from theoretical estimation (normalized dose at dmax). The same measurements for 10 MV beams are lowered by 9.0 to 13.5%. The variations of measured exit dose for different field sizes are found to be within 2.5%. The exit doses with added backscatter material from 2 mm up to 15 cm, shows gradual increase and the saturated values agreed within 1.5% with the expected results for both beams. The measured exit doses in humanoid breast phantom as well as in the clinical trial on patients undergoing radiotherapy also agreed with the predicted results based on phantom measurements. The authors' viewpoint is that this technique provides sufficient information to design exit surface bolus to restore build down effect in cases where part of the exit surface is being considered as a target volume. It indicates that the technique could be translated for in vivo dose measurements, which may be a conspicuous step of quality assurance in clinical practice.

  19. The impact of various protective tools on the dose reduction in the eye lens in an interventional cardiology-clinical study.

    PubMed

    Domienik, J; Bissinger, A; Grabowicz, W; Jankowski, Ł; Kręcki, R; Makowski, M; Masiarek, K; Plewka, M; Lubiński, A; Peruga, J Z

    2016-06-01

    The aim of the study was to check, in clinical practice, the potential for the dose reduction of lead eyewear and a ceiling-suspended shield used to protect the eye lens of physicians working in interventional cardiology. To this end, for the lead eyewear, the dose reduction factors were derived to correct the readings from a dosimeter used routinely outside the glasses. Four types of lead eyewear with attached loose thermoluminescent dosimeters and EYE-D dosimeters were worn by physicians in two clinical centres, for two-month periods, during coronary angiography (CA), percutaneous coronary intervention (PCI), and pacemaker procedures. In order to analyse, separately, how a ceiling-suspended lead screen absorbs the scattered radiation, a series of measurements was carried out during single CA/PCI procedures performed with and without the protection. The lead eyewear may reduce the doses to the eye closest to the x-ray tube by a factor between 1.1 and 3.4, depending on its model and the physician's position. The effectiveness of the eyewear may, however, vary-even for the same model and physician-almost twofold between different working periods. The ceiling-suspended shield decreases the doses in clinical practice by a factor of 2.3. The annual eye lens doses without the eyewear estimated from routine measurements are high-above or close to the new eye lens dose limit established by the recent EU Basic Safety Standards, even though the ceiling-suspended shield was used. Therefore, to comply with the new dose limit that is set in the Directive, protection of the eyes of physicians with high workloads might require the use of both the eyewear and the ceiling-suspended shield.

  20. Patient dose in interventional radiology: a multicentre study of the most frequent procedures in France.

    PubMed

    Etard, Cécile; Bigand, Emeline; Salvat, Cécile; Vidal, Vincent; Beregi, Jean Paul; Hornbeck, Amaury; Greffier, Joël

    2017-10-01

    A national retrospective survey on patient doses was performed by the French Society of Medical physicists to assess reference levels (RLs) in interventional radiology as required by the European Directive 2013/59/Euratom. Fifteen interventional procedures in neuroradiology, vascular radiology and osteoarticular procedures were analysed. Kerma area product (KAP), fluoroscopy time (FT), reference air kerma and number of images were recorded for 10 to 30 patients per procedure. RLs were calculated as the 3rd quartiles of the distributions. Results on 4600 procedures from 36 departments confirmed the large variability in patient dose for the same procedure. RLs were proposed for the four dosimetric estimators and the 15 procedures. RLs in terms of KAP and FT were 90 Gm.cm 2 and 11 mins for cerebral angiography, 35 Gy.cm 2 and 16 mins for biliary drainage, 75 Gy.cm 2 and 6 mins for lower limbs arteriography and 70 Gy.cm 2 and 11 mins for vertebroplasty. For these four procedures, RLs were defined according to the complexity of the procedure. For all the procedures, the results were lower than most of those already published. This study reports RLs in interventional radiology based on a national survey. Continual evolution of practices and technologies requires regular updates of RLs. • Delivered dose in interventional radiology depends on procedure, practice and patient. • National RLs are proposed for 15 interventional procedures. • Reference levels (RLs) are useful to benchmark practices and optimize protocols. • RLs are proposed for kerma area product, air kerma, fluoroscopy time and number of images. • RLs should be adapted to the procedure complexity and updated regularly.

  1. Dose and dose rate effects of whole-body gamma-irradiation: I. Lymphocytes and lymphoid organs

    NASA Technical Reports Server (NTRS)

    Pecaut, M. J.; Nelson, G. A.; Gridley, D. S.

    2001-01-01

    The major goal of part I of this study was to compare varying doses and dose rates of whole-body gamma-radiation on lymphoid cells and organs. C57BL/6 mice (n = 75) were exposed to 0, 0.5, 1.5, and 3.0 Gy gamma-rays (60Co) at 1 cGy/min (low-dose rate, LDR) and 80 cGy/min (high-dose rate, HDR) and euthanized 4 days later. A significant dose-dependent loss of spleen mass was observed with both LDR and HDR irradiation; for the thymus this was true only with HDR. Decreasing leukocyte and lymphocyte numbers occurred with increasing dose in blood and spleen at both dose rates. The numbers (not percentages) of CD3+ T lymphocytes decreased in the blood in a dose-dependent manner at both HDR and LDR. Splenic T cell counts decreased with dose only in HDR groups; percentages increased with dose at both dose rates. Dose-dependent decreases occurred in CD4+ T helper and CD8+ T cytotoxic cell counts at HDR and LDR. In the blood the percentages of CD4+ cells increased with increasing dose at both dose rates, whereas in the spleen the counts decreased only in the HDR groups. The percentages of the CD8+ population remained stable in both blood and spleen. CD19+ B cell counts and percentages in both compartments declined markedly with increasing HDR and LDR radiation. NK1.1+ natural killer cell numbers and proportions remained relatively stable. Overall, these data indicate that the observed changes were highly dependent on the dose, but not dose rate, and that cells in the spleen are more affected by dose rate than those in blood. The results also suggest that the response of lymphocytes in different body compartments may be variable.

  2. Pharmacotherapy in pediatric epilepsy: from trial and error to rational drug and dose selection - a long way to go.

    PubMed

    van Dijkman, Sven C; Alvarez-Jimenez, Ricardo; Danhof, Meindert; Della Pasqua, Oscar

    2016-10-01

    Whereas ongoing efforts in epilepsy research focus on the underlying disease processes, the lack of a physiologically based rationale for drug and dose selection contributes to inadequate treatment response in children. In fact, limited information on the interindividual variation in pharmacokinetics and pharmacodynamics of anti-epileptic drugs (AEDs) in children drive prescription practice, which relies primarily on dose regimens according to a mg/kg basis. Such practice has evolved despite advancements in pediatric pharmacology showing that growth and maturation processes do not correlate linearly with changes in body size. In this review we aim to provide 1) a comprehensive overview of the sources of variability in the response to AEDs, 2) insight into novel methodologies to characterise such variation and 3) recommendations for treatment personalisation. The use of pharmacokinetic-pharmacodynamic principles in clinical practice is hindered by the lack of biomarkers and by practical constraints in the evaluation of polytherapy. The identification of biomarkers and their validation as tools for drug development and therapeutics will require some time. Meanwhile, one should not miss the opportunity to integrate the available pharmacokinetic data with modeling and simulation concepts to prevent further delays in the development of personalised treatments for pediatric patients.

  3. The Research of Improving the Particleboard Glue Dosing Process Based on TRIZ Analysis

    NASA Astrophysics Data System (ADS)

    Yu, Huiling; Fan, Delin; Zhang, Yizhuo

    This research creates a design methodology by synthesizing the Theory of Inventive Problem Solving (TRIZ) and cascade control based on Smith predictor. The particleboard glue supplying and dosing system case study defines the problem and the solution using the methodology proposed in the paper. Status difference existing in the gluing dosing process of particleboard production usually causes gluing volume inaccurately. In order to solve the problem above, we applied the TRIZ technical contradiction and inventive principle to improve the key process of particleboard production. The improving method mapped inaccurate problem to TRIZ technical contradiction, the prior action proposed Smith predictor as the control algorithm in the glue dosing system. This research examines the usefulness of a TRIZ based problem-solving process designed to improve the problem-solving ability of users in addressing difficult or reoccurring problems and also testify TRIZ is practicality and validity. Several suggestions are presented on how to approach this problem.

  4. Dose rate in brachytherapy using after-loading machine: pulsed or high-dose rate?

    PubMed

    Hannoun-Lévi, J-M; Peiffert, D

    2014-10-01

    Since February 2014, it is no longer possible to use low-dose rate 192 iridium wires due to the end of industrial production of IRF1 and IRF2 sources. The Brachytherapy Group of the French society of radiation oncology (GC-SFRO) has recommended switching from iridium wires to after-loading machines. Two types of after-loading machines are currently available, based on the dose rate used: pulsed-dose rate or high-dose rate. In this article, we propose a comparative analysis between pulsed-dose rate and high-dose rate brachytherapy, based on biological, technological, organizational and financial considerations. Copyright © 2014 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.

  5. New use of low-dose aspirin and risk of colorectal cancer by stage at diagnosis: a nested case-control study in UK general practice.

    PubMed

    García Rodríguez, Luis A; Soriano-Gabarró, Montse; Bromley, Susan; Lanas, Angel; Cea Soriano, Lucía

    2017-09-07

    Evidence from clinical trial populations suggests low-dose aspirin reduces the risk of colorectal cancer (CRC). Part of this reduction in risk might be due to protection against metastatic disease. We investigated the risk of CRC among new-users of low-dose aspirin (75-300 mg), including risk by stage at diagnosis. Using The Health Improvement Network, we conducted a cohort study with nested case-control analysis. Two cohorts (N = 170,336 each) aged 40-89 years from 2000 to 2009 and free of cancer were identified: i) new-users of low-dose aspirin, ii) non-users of low-dose aspirin, at start of follow-up, matched by age, sex and previous primary care practitioner visits. Patients were followed for up to 12 years to identify incident CRC. 10,000 frequency-matched controls were selected by incidence density sampling where the odds ratio is an unbiased estimator of the incidence rate ratio (RR). RRs with 95% confidence intervals were calculated. Low-dose aspirin use was classified 'as-treated' independent from baseline exposure status to account for changes in exposure during follow-up. Current users of low-dose aspirin (use on the index date or in the previous 90 days) had a significantly reduced risk of CRC, RR 0.66 (95% CI 0.60-0.74). The reduction in risk was apparent across all age groups, and was unrelated to dose, indication, gender, CRC location or case-fatality status. Reduced risks occurred throughout treatment duration and with all low-dose aspirin doses. RRs by aspirin indication were 0.71 (0·63-0·79) and 0.60 (0.53-0.68) for primary and secondary cardiovascular protection, respectively. Among cases with staging information (n = 1421), RRs for current use of low-dose aspirin were 0.94 (0.66-1.33) for Dukes Stage A CRC, 0.54 (0.42-0.68) for Dukes B, 0.71 (0.56-0.91) for Dukes C, and 0.60 (0.48-0.74) for Dukes D. After 5 years' therapy, the RR for Dukes Stage A CRC was 0.53 (0.24-1.19). Patients starting low-dose aspirin therapy have a reduced

  6. [Doses to organs at risk in conformational radiotherapy and stereotaxic irradiation: The heart].

    PubMed

    Vandendorpe, B; Servagi Vernat, S; Ramiandrisoa, F; Bazire, L; Kirova, Y M

    2017-10-01

    Radiation therapy of breast cancer, Hodgkin lymphoma, lung cancer and others thoracic irradiations induce an ionizing radiation dose to the heart. Irradiation of the heart, associated with patient cardiovascular risk and cancer treatment-induced cardiotoxicity, increase cardiovascular mortality. The long survival after breast or Hodgkin lymphoma irradiation requires watching carefully late treatment toxicity. The over-risk of cardiac events is related to the dose received by the heart and the irradiated cardiac volume. The limitation of cardiac irradiation should be a priority in the planning of thoracic irradiations. Practices have to be modified, using modern techniques to approach of the primary objective of radiotherapy which is to optimize the dose to the target volume, sparing healthy tissues, in this case the heart. We have reviewed the literature on cardiac toxicity induced by conformational tridimensional radiation therapy, intensity-modulated radiation therapy or stereotactic body radiation therapy, in order to evaluate the possibilities to limit cardiotoxicity. Finally, we summarise the recommendations on dose constraints to the heart and coronary arteries. Copyright © 2017 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.

  7. Dose-responses for mortality from cerebrovascular and heart diseases in atomic bomb survivors: 1950-2003.

    PubMed

    Schöllnberger, Helmut; Eidemüller, Markus; Cullings, Harry M; Simonetto, Cristoforo; Neff, Frauke; Kaiser, Jan Christian

    2018-03-01

    The scientific community faces important discussions on the validity of the linear no-threshold (LNT) model for radiation-associated cardiovascular diseases at low and moderate doses. In the present study, mortalities from cerebrovascular diseases (CeVD) and heart diseases from the latest data on atomic bomb survivors were analyzed. The analysis was performed with several radio-biologically motivated linear and nonlinear dose-response models. For each detrimental health outcome one set of models was identified that all fitted the data about equally well. This set was used for multi-model inference (MMI), a statistical method of superposing different models to allow risk estimates to be based on several plausible dose-response models rather than just relying on a single model of choice. MMI provides a more accurate determination of the dose response and a more comprehensive characterization of uncertainties. It was found that for CeVD, the dose-response curve from MMI is located below the linear no-threshold model at low and medium doses (0-1.4 Gy). At higher doses MMI predicts a higher risk compared to the LNT model. A sublinear dose-response was also found for heart diseases (0-3 Gy). The analyses provide no conclusive answer to the question whether there is a radiation risk below 0.75 Gy for CeVD and 2.6 Gy for heart diseases. MMI suggests that the dose-response curves for CeVD and heart diseases in the Lifespan Study are sublinear at low and moderate doses. This has relevance for radiotherapy treatment planning and for international radiation protection practices in general.

  8. Mutagenesis and repair by low doses of α radiation in mammalian cells

    PubMed Central

    Puck, Theodore T.; Johnson, Robert; Webb, Patricia; Cui, Helen; Valdez, Joseph G.; Crissman, Harry

    2002-01-01

    Low doses of α radiation in basements have been causally implicated in lung cancer. Previous studies have concentrated on high dose effects, for which no significant repair was found. In the present study, the methodology for measuring mutation by quantitating mitotic breaks and gaps was found to be applicable to G2-phase Chinese hamster ovary cells irradiated with 10–50 cGy of α radiation. The mutation yield in such cells closely resembles that of γ irradiation. Caffeine, which inhibits repair, produces the same straight line increase of α and γ mutation yields plotted against the dose. In the absence of caffeine, the repair of α radiation lesions is almost twice as great as for γ radiation. Mitotic index changes substantiate these interpretations. It is proposed that the higher ion density associated with α radiation may result in fewer lesions being missed by the repair processes. The quantitation of chromosomal lesions for G2 cells exposed to low doses of α radiation, γ radiation, or chemical mutagens in the presence and absence of caffeine is a rapid and reproducible methodology. Protection from mutational disease in a fashion similar to the use of sanitation for infectious disease appears practical. PMID:12198179

  9. Variation in intravenous iron use internationally and over time: the Dialysis Outcomes and Practice Patterns Study (DOPPS).

    PubMed

    Bailie, George R; Larkina, Maria; Goodkin, David A; Li, Yun; Pisoni, Ronald L; Bieber, Brian; Mason, Nancy; Tong, Lin; Locatelli, Francesco; Marshall, Mark R; Inaba, Masaki; Robinson, Bruce M

    2013-10-01

    To examine patterns of intravenous (IV) iron use across 12 countries from 1999 to 2011. Trends in iron use are described among 32 192 hemodialysis (HD) patients in the Dialysis Outcomes and Practice Patterns Study. Adjusted associations of IV iron dose with serum ferritin and transferrin saturation (TSAT) values were also studied. IV iron was administered to 50% of patients over 4 months in 1999, increasing to 71% during 2009-11, with increasing use in most countries. Among patients receiving IV iron, the mean monthly dose increased from 232 ± 167 to 281 ± 211 mg. Most countries used 3 to 4 doses/month, but Canada used about 2 doses/month, Italy increased from 3 to almost 6 doses/month and Germany used 5 to 6 doses/month. The USA and most European countries predominantly used iron sucrose and sodium ferric gluconate. A significant use of iron dextran was limited to Canada and France; iron polymaltose was used in Australia and New Zealand; and Japan used ferric oxide saccharate, chondroitin polysulfate iron complex and cideferron. Ferritin values rose in most countries: 22% of patients had ≥ 800 ng/mL in the recent years of study. TSAT levels increased to a lesser degree over time. Japan had much lower IV iron dosing and ferritin levels, but similar TSAT levels. In adjusted analyses, serum ferritin and TSAT levels increased signifcantly by 14 ng/mL and 0.16%, respectively, for every 100 mg/month higher mean monthly iron dose. IV iron prescription patterns varied between countries and changed over time from 1999 to 2011. IV iron use and dose increased in most countries, with notable increases in ferritin but not TSAT levels. With rising cumulative IV iron doses, studies of the effects of changing IV iron dosing and other anemia management practices on clinical outcomes should be a high priority.

  10. On effective dose for radiotherapy based on doses to nontarget organs and tissues

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Uselmann, Adam J., E-mail: ajuselmann@wisc.edu; Thomadsen, Bruce R.

    2015-02-15

    Purpose: The National Council for Radiation Protection and Measurement (NCRP) published estimates for the collective population dose and the mean effective dose to the population of the United States from medical imaging procedures for 1980/1982 and for 2006. The earlier report ignored the effective dose from radiotherapy and the latter gave a cursory discussion of the topic but again did not include it in the population exposure for various reasons. This paper explains the methodology used to calculate the effective dose in due to radiotherapy procedures in the latter NCRP report and revises the values based on more detailed modeling.more » Methods: This study calculated the dose to nontarget organs from radiotherapy for reference populations using CT images and published peripheral dose data. Results: Using International Commission on Radiological Protection (ICRP) 60 weighting factors, the total effective dose to nontarget organs in radiotherapy patients is estimated as 298 ± 194 mSv per patient, while the U.S. population effective dose is 0.939 ± 0.610 mSv per person, with a collective dose of 283 000 ± 184 000 person Sv per year. Using ICRP 103 weighting factors, the effective dose is 281 ± 183 mSv per patient, 0.887 ± 0.577 mSv per person in the U.S., and 268 000 ± 174 000 person Sv per year. The uncertainty in the calculations is largely governed by variations in patient size, which was accounted for by considering a range of patient sizes and taking the average treatment site to nontarget organ distance. Conclusions: The methods used to estimate the effective doses from radiotherapy used in NCRP Report No. 160 have been explained and the values updated.« less

  11. Clear, Hold, and Build: The Role of Culture in the Creation of Local Security Forces

    DTIC Science & Technology

    2006-05-25

    welcome a national agency as a neutral arbitrator of local (especially inter -tribal) disputes if it is seen as scrupulously neutral and honest and...practice of military dictatorship. As used here it refers to the tendency for state security institutions to become the de facto or de jure dominant...or inter -tribal or political faction violence. These, in turn, may accelerate local problems and trends; if not balanced between necessity and reform

  12. Calculation of midplane dose for total body irradiation from entrance and exit dose MOSFET measurements.

    PubMed

    Satory, P R

    2012-03-01

    This work is the development of a MOSFET based surface in vivo dosimetry system for total body irradiation patients treated with bilateral extended SSD beams using PMMA missing tissue compensators adjacent to the patient. An empirical formula to calculate midplane dose from MOSFET measured entrance and exit doses has been derived. The dependency of surface dose on the air-gap between the spoiler and the surface was investigated by suspending a spoiler above a water phantom, and taking percentage depth dose measurements (PDD). Exit and entrances doses were measured with MOSFETs in conjunction with midplane doses measured with an ion chamber. The entrance and exit doses were combined using an exponential attenuation formula to give an estimate of midplane dose and were compared to the midplane ion chamber measurement for a range of phantom thicknesses. Having a maximum PDD at the surface simplifies the prediction of midplane dose, which is achieved by ensuring that the air gap between the compensator and the surface is less than 10 cm. The comparison of estimated midplane dose and measured midplane dose showed no dependence on phantom thickness and an average correction factor of 0.88 was found. If the missing tissue compensators are kept within 10 cm of the patient then MOSFET measurements of entrance and exit dose can predict the midplane dose for the patient.

  13. Best practicable means (BPM) and as low as reasonably practicable (ALARP) in action at Sellafield.

    PubMed

    Morley, Bob

    2004-03-01

    Operators within the UK nuclear industry are required to employ 'best practicable means' (BPM) to control and minimise radioactive discharges. The requirement for the use of BPM is in order to ensure that doses from discharges are as low as reasonably practicable (ALARP). This facet is increasingly becoming the principal feature of discharge authorisations issued by the Environment Agencies under the Radioactive Substances Act, 1993 (RSA 93), which are enforceable by law. It is important to state at the outset, however, that scientific assessments to date indicate that there are no expectations of environmental harm from authorised discharges, even where those discharges have historically been up to two orders of magnitude higher than current levels. There is also no evidence to indicate that foreseeable future discharges from the Sellafield site will make any contribution to environmental harm.

  14. [Vasopressin intravenous infusion causes dose dependent adverse cardiovascular effects in anesthetized dogs.

    PubMed

    Martins, Luiz Cláudio; Sabha, Maricene; Paganelli, Maria Ondina; Coelho, Otávio Rizzi; Ferreira-Melo, Silvia Elaine; Moreira, Marcos Mello; Cavalho, Adriana Camargo de; Araujo, Sebastião; Moreno Junior, Heitor

    2010-01-15

    BACKGROUND: Arginine vasopressin (AVP) has been broadly used in the management of vasodilatory shock. However, there are many concerns regarding its clinical use, especially in high doses, as it can be associated with adverse cardiovascular events. OBJECTIVE: To investigate the cardiovascular effects of AVP in continuous IV infusion on hemodynamic parameters in dogs. METHODS: Sixteen healthy mongrel dogs, anesthetized with pentobarbital were intravascularly catheterized, and randomly assigned to: control (saline-placebo; n=8) and AVP (n=8) groups. The study group was infused with AVP for three consecutive 10-minute periods at logarithmically increasing doses (0.01; 0.1 and 1.0U/kg/min), at them 20-min intervals. Heart rate (HR) and intravascular pressures were continuously recorded. Cardiac output was measured by the thermodilution method. RESULTS: No significant hemodynamic effects were observed during 0.01U/kg/min of AVP infusion, but at higher doses (0.1 and 1.0U/kg/min) a progressive increase in mean arterial pressure (MAP) and systemic vascular resistance index (SVRI) were observed, with a significant decrease in HR and the cardiac index (CI). A significant increase in the pulmonary vascular resistance index (PVRI) was also observed with the 1.0U/kg/min dose, mainly due to the decrease in the CI. CONCLUSION: AVP, when administered at doses between 0.1 and 1.0U/kg/min, induced significant increases in MAP and SVRI, with negative inotropic and chronotropic effects in healthy animals. Although these doses are ten to thousand times greater than those routinely used for the management of vasodilatory shock, our data confirm that AVP might be used carefully and under strict hemodynamic monitoring in clinical practice, especially if doses higher than 0.01 U/kg/min are needed. Martins, LC et al.

  15. Effect of Gold Nanoparticles on Prostate Dose Distribution under Ir-192 Internal and 18 MV External Radiotherapy Procedures Using Gel Dosimetry and Monte Carlo Method.

    PubMed

    Khosravi, H; Hashemi, B; Mahdavi, S R; Hejazi, P

    2015-03-01

    Gel polymers are considered as new dosimeters for determining radiotherapy dose distribution in three dimensions. The ability of a new formulation of MAGIC-f polymer gel was assessed by experimental measurement and Monte Carlo (MC) method for studying the effect of gold nanoparticles (GNPs) in prostate dose distributions under the internal Ir-192 and external 18MV radiotherapy practices. A Plexiglas phantom was made representing human pelvis. The GNP shaving 15 nm in diameter and 0.1 mM concentration were synthesized using chemical reduction method. Then, a new formulation of MAGIC-f gel was synthesized. The fabricated gel was poured in the tubes located at the prostate (with and without the GNPs) and bladder locations of the phantom. The phantom was irradiated to an Ir-192 source and 18 MV beam of a Varian linac separately based on common radiotherapy procedures used for prostate cancer. After 24 hours, the irradiated gels were read using a Siemens 1.5 Tesla MRI scanner. The absolute doses at the reference points and isodose curves resulted from the experimental measurement of the gels and MC simulations following the internal and external radiotherapy practices were compared. The mean absorbed doses measured with the gel in the presence of the GNPs in prostate were 15% and 8 % higher than the corresponding values without the GNPs under the internal and external radiation therapies, respectively. MC simulations also indicated a dose increase of 14 % and 7 % due to presence of the GNPs, for the same experimental internal and external radiotherapy practices, respectively. There was a good agreement between the dose enhancement factors (DEFs) estimated with MC simulations and experiment gel measurements due to the GNPs. The results indicated that the polymer gel dosimetry method as developed and used in this study, can be recommended as a reliable method for investigating the DEF of GNPs in internal and external radiotherapy practices.

  16. Practice and documentation of palliative sedation: a quality improvement initiative

    PubMed Central

    McKinnon, M.; Azevedo, C.; Bush, S.H.; Lawlor, P.; Pereira, J.

    2014-01-01

    Background Palliative sedation (ps), the continuous use of sedating doses of medication to intentionally reduce consciousness and relieve refractory symptoms at end of life, is ethically acceptable if administered according to standards of best practice. Procedural guidelines outlining the appropriate use of ps and the need for rigorous documentation have been developed. As a quality improvement strategy, we audited the practice and documentation of ps on our palliative care unit (pcu). Methods A pharmacy database search of admissions in 2008 identified, for a subsequent chart review, patients who had received either a continuous infusion of midazolam (≥10 mg/24 h), regular parenteral dosing of methotrimeprazine (≥75 mg daily), or regular phenobarbital. Documentation of the decision-making process, consent, and medication use was collected using a data extraction form based on current international ps standards. Results Interpretation and comparison of data were difficult because of an apparent lack of a consistent operational definition of ps. Patient records had no specific documentation in relation to ps initiation, to clearly identified refractory symptoms, and to informed consent in 60 (64.5%), 43 (46.2%), and 38 (40.9%) charts respectively. Variation in the medications used was marked: 54 patients (58%) were started on a single agent and 39 (42%), on multiple agents. The 40 patients (43%) started on midazolam alone received a mean daily dose of 21.4 mg (standard deviation: 24.6 mg). Conclusions The lack of documentation and standardized practice of ps on our pcu has resulted in a quality improvement program to address those gaps. They also highlight the importance of conducting research and developing clinical guidelines in this area. PMID:24764700

  17. Sponsorship in non-commercial clinical trials: definitions, challenges and the role of Good Clinical Practices guidelines.

    PubMed

    Ravinetto, Raffaella; De Nys, Katelijne; Boelaert, Marleen; Diro, Ermias; Meintjes, Graeme; Adoke, Yeka; Tagbor, Harry; Casteels, Minne

    2015-12-30

    Non-commercial clinical research plays an increasingly essential role for global health. Multiple partners join in international consortia that operate under the limited timeframe of a specific funding period. One organisation (the sponsor) designs and carries out the trial in collaboration with research partners, and is ultimately responsible for the trial's scientific, ethical, regulatory and legal aspects, while another organization, generally in the North (the funder), provides the external funding and sets funding conditions. Even if external funding mechanisms are key for most non-commercial research, the dependence on an external funder's policies may heavily influence the choices of a sponsor. In addition, the competition for accessing the available external funds is great, and non-commercial sponsors may not be in a position to discuss or refuse standard conditions set by a funder. To see whether the current definitions adequately address the intricacies of sponsorship in externally-funded trials, we looked at how a "sponsor" of clinical trials is defined in selected international guidelines, with particular focus on international Good Clinical Practices codes, and in selected European and African regulations/legislations. Our limited analysis suggests that the sponsors definition from the 1995 WHO Good Clinical Practices code has been integrated as such into many legislations, guidelines and regulations, and that it is not adequate to cover today's reality of funding arrangements in global health, where the legal responsibility and the funding source are de facto split. In agreement with other groups, we suggest that the international Good Clinical Practices codes should be updated to reflect the reality of non-commercial clinical research. In particular, they should explicitly include the distinction between commercial and non-commercial sponsors, and provide guidance to non-commercial sponsors for negotiating with external funding agencies and other

  18. Randomised clinical trial: a 'nudge' strategy to modify endoscopic sedation practice.

    PubMed

    Harewood, G C; Clancy, K; Engela, J; Abdulrahim, M; Lohan, K; O'Reilly, C

    2011-07-01

    In behavioural economics, a 'nudge' describes configuration of a choice to encourage a certain action without taking away freedom of choice. To determine the impact of a 'nudge' strategy - prefilling either 3mL or 5mL syringes with midazolam - on endoscopic sedation practice. Consecutive patients undergoing sedation for EGD or colonoscopy were enrolled. On alternate weeks, midazolam was prefilled in either 3mL or 5mL syringes. Preprocedure sedation was administered by the endoscopist to achieve moderate conscious sedation; dosages were at the discretion of the endoscopist. Meperidine was not prefilled. Overall, 120 patients received sedation for EGD [59 (5mL), 61 (3mL)] and 86 patients were sedated for colonoscopy [38 (5mL), 48 (3mL)]. For EGDs, average midazolam dose was significantly higher in the 5-mL group (5.2mg) vs. 3-mL group (3.3mg), (P<0.0001); for colonoscopies, average midazolam dose was also significantly higher in the 5-mL group (5.1mg) vs. 3-mL group (3.3mg), (P<0.0001). There was no significant difference in mean meperidine dose (42.1mg vs. 42.8mg, P=0.9) administered to both colonoscopy groups. No adverse sedation-related events occurred; no patient required reversal of sedation. These findings demonstrate that 'nudge' strategies may hold promise in modifying endoscopic sedation practice. Further research is required to explore the utility of 'nudges' in impacting other aspects of endoscopic practice. © 2011 Blackwell Publishing Ltd.

  19. Absorbed dose to man from the Se-75 labeled conjugated bile salt SeHCAT: concise communication.

    PubMed

    Soundy, R G; Simpson, J D; Ross, H M; Merrick, M V

    1982-02-01

    The absorbed radiation dose that would result from the oral or intravenous administration of SeHCAT (23-[75Se]selena-25-homotaurocholate) has been calculated using the MIRD tables and formulas and data from measurements of whole-body distribution and from long-term whole-body counting in rats, mice, and man. When SeHCAT is administered to normal subjects, the gallbladder is the critical organ, receiving 12 mrad (oral dose) or 22 mrad (i.v.) per microcurie. The whole-body dose is 1 mrad/microCi, whatever the route of administration. In severe hepatic failure the liver might receive 200 mrad/microCi. The activity likely to be used in routine clinical practice is 10 microCi. Where a whole-body counter is used, an activity of 1 microCi has proved adequate. Even at an administered activity of 25 microCi, the absorbed dose is small compared with established techniques of investigating the gastrointestinal tract.

  20. Dose escalation using conformal high-dose-rate brachytherapy improves outcome in unfavorable prostate cancer.

    PubMed

    Martinez, Alvaro A; Gustafson, Gary; Gonzalez, José; Armour, Elwood; Mitchell, Chris; Edmundson, Gregory; Spencer, William; Stromberg, Jannifer; Huang, Raywin; Vicini, Frank

    2002-06-01

    To overcome radioresistance for patients with unfavorable prostate cancer, a prospective trial of pelvic external beam irradiation (EBRT) interdigitated with dose-escalating conformal high-dose-rate (HDR) prostate brachytherapy was performed. Between November 1991 and August 2000, 207 patients were treated with 46 Gy pelvic EBRT and increasing HDR brachytherapy boost doses (5.50-11.5 Gy/fraction) during 5 weeks. The eligibility criteria were pretreatment prostate-specific antigen level >or=10.0 ng/mL, Gleason score >or=7, or clinical Stage T2b or higher. Patients were divided into 2 dose levels, low-dose biologically effective dose <93 Gy (58 patients) and high-dose biologically effective dose >93 Gy (149 patients). No patient received hormones. We used the American Society for Therapeutic Radiology and Oncology definition for biochemical failure. The median age was 69 years. The mean follow-up for the group was 4.4 years, and for the low and high-dose levels, it was 7.0 and 3.4 years, respectively. The actuarial 5-year biochemical control rate was 74%, and the overall, cause-specific, and disease-free survival rate was 92%, 98%, and 68%, respectively. The 5-year biochemical control rate for the low-dose group was 52%; the rate for the high-dose group was 87% (p <0.001). Improvement occurred in the cause-specific survival in favor of the brachytherapy high-dose level (p = 0.014). On multivariate analysis, a low-dose level, higher Gleason score, and higher nadir value were associated with increased biochemical failure. The Radiation Therapy Oncology Group Grade 3 gastrointestinal/genitourinary complications ranged from 0.5% to 9%. The actuarial 5-year impotency rate was 51%. Pelvic EBRT interdigitated with transrectal ultrasound-guided real-time conformal HDR prostate brachytherapy boost is both a precise dose delivery system and a very effective treatment for unfavorable prostate cancer. We demonstrated an incremental beneficial effect on biochemical control and