Sample records for factors determine anatomic

  1. Anatomic Sites and Associated Clinical Factors for Deep Dyspareunia.

    PubMed

    Yong, Paul J; Williams, Christina; Yosef, Ali; Wong, Fontayne; Bedaiwy, Mohamed A; Lisonkova, Sarka; Allaire, Catherine

    2017-09-01

    Deep dyspareunia negatively affects women's sexual function. There is a known association between deep dyspareunia and endometriosis of the cul-de-sac or uterosacral ligaments in reproductive-age women; however, other factors are less clear in this population. To identify anatomic sites and associated clinical factors for deep dyspareunia in reproductive-age women at a referral center. This study involved the analysis of cross-sectional baseline data from a prospective database of 548 women (87% consent rate) recruited from December 2013 through April 2015 at a tertiary referral center for endometriosis and/or pelvic pain. Exclusion criteria included menopausal status, age at least 50 years, previous hysterectomy or oophorectomy, and not sexually active. We performed a standardized endovaginal ultrasound-assisted pelvic examination to palpate anatomic structures for tenderness and reproduce deep dyspareunia. Multivariable regression was used to determine which tender anatomic structures were independently associated with deep dyspareunia severity and to identify clinical factors independently associated with each tender anatomic site. Severity of deep dyspareunia on a numeric pain rating scale of 0 to 10. Severity of deep dyspareunia (scale = 0-10) was independently associated with tenderness of the bladder (b = 0.88, P = .018), pelvic floor (levator ani) (b = 0.66, P = .038), cervix and uterus (b = 0.88, P = .008), and cul-de-sac or uterosacral ligaments (b = 1.39, P < .001), but not with the adnexa (b = -0.16, P = 0.87). The number of tender anatomic sites was significantly correlated with more severe deep dyspareunia (Spearman r = 0.34, P < .001). For associated clinical factors, greater depression symptom severity was specifically associated with tenderness of the bladder (b = 1.05, P = .008) and pelvic floor (b = 1.07, P < .001). A history of miscarriage was specifically associated with tenderness of the cervix and uterus (b = 2.24, P = .001

  2. Determining customer satisfaction in anatomic pathology.

    PubMed

    Zarbo, Richard J

    2006-05-01

    Measurement of physicians' and patients' satisfaction with laboratory services has become a standard practice in the United States, prompted by national accreditation requirements. Unlike other surveys of hospital-, outpatient care-, or physician-related activities, no ongoing, comprehensive customer satisfaction survey of anatomic pathology services is available for subscription that would allow continual benchmarking against peer laboratories. Pathologists, therefore, must often design their own local assessment tools to determine physician satisfaction in anatomic pathology. To describe satisfaction survey design that would elicit specific information from physician customers about key elements of anatomic pathology services. The author shares his experience in biannually assessing customer satisfaction in anatomic pathology with survey tools designed at the Henry Ford Hospital, Detroit, Mich. Benchmarks for physician satisfaction, opportunities for improvement, and characteristics that correlated with a high level of physician satisfaction were identified nationally from a standardized survey tool used by 94 laboratories in the 2001 College of American Pathologists Q-Probes quality improvement program. In general, physicians are most satisfied with professional diagnostic services and least satisfied with pathology services related to poor communication. A well-designed and conducted customer satisfaction survey is an opportunity for pathologists to periodically educate physician customers about services offered, manage unrealistic expectations, and understand the evolving needs of the physician customer. Armed with current information from physician customers, the pathologist is better able to strategically plan for resources that facilitate performance improvements in anatomic pathology laboratory services that align with evolving clinical needs in health care delivery.

  3. Laparoscopic repair of giant paraesophageal hernia: are there factors associated with anatomic recurrence?

    PubMed

    Antiporda, Michael; Veenstra, Benjamin; Jackson, Chloe; Kandel, Pujan; Daniel Smith, C; Bowers, Steven P

    2018-02-01

    Repair of giant paraesophageal hernia (PEH) is associated with a favorably high rate of symptom improvement; however, rates of recurrence by objective measures remain high. Herein we analyze our experience with laparoscopic giant PEH repair to determine what factors if any can predict anatomic recurrence. We prospectively collected data on PEH characteristics, variations in operative techniques, and surgeon factors for 595 patients undergoing laparoscopic PEH repair from 2008 to 2015. Upper GI study was performed at 6 months postoperatively and selectively thereafter-any supra-diaphragmatic stomach was considered hiatal hernia recurrence. Exclusion criteria included revisional operation (22.4%), size <5 cm (17.6%), inadequate follow-up (17.8%), and confounding concurrent operations (6.9%). Inclusion criteria were met by 202 patients (31% male, median age 71 years, and median BMI 28.7). At a median follow-up of 6 months (IQR 6-12), overall anatomic recurrence rate was 34.2%. Symptom recurrence rate was 9.9% and revisional operation was required in ten patients (4.9%). Neither patient demographics nor PEH characteristics (size, presence of Cameron erosions, esophagitis, or Barrett's) correlated with anatomic recurrence. Technical factors at operation (mobilized intra-abdominal length of esophagus, Collis gastroplasty, number of anterior/posterior stitches, use of crural buttress, use of pledgeted or mattress sutures, or gastrostomy) were also not correlated with recurrence. Regarding surgeon factors, annual volume of fewer than ten cases per year was associated with increased risk of anatomic failure (54 vs 33%, P = 0.02). Multivariate analysis identified surgeon experience (<10 cases per year) as an independent factor associated with early hiatal hernia recurrence (OR 3.7, 95% CI 1.34-10.9). Laparoscopic repair of giant PEH is associated with high anatomic recurrence rate but excellent symptom control. PEH characteristics and technical operative variables do

  4. Determinants of alveolar ridge preservation differ by anatomic location

    PubMed Central

    Leblebicioglu, Binnaz; Salas, Mabel; Ort, Yirae; Johnson, Ashley; Yildiz, Vedat O.; Kim, Do-Gyoon; Agarwal, Sudha; Tatakis, Dimitris N.

    2016-01-01

    Aim To investigate and compare outcomes following alveolar ridge preservation (ARP) in posterior maxilla and mandible. Methods Twenty-four patients (54 ± 3 years) with single posterior tooth extraction were included. ARP was performed with freeze-dried bone allograft and collagen membrane. Clinical parameters were recorded at extraction and re-entry. Harvested bone cores were analysed by microcomputed tomography (micro-CT), histomorphometry and immunohistochemistry. Results In both jaws, ARP prevented ridge height loss, but ridge width was significantly reduced by approximately 2.5 mm. Healing time, initial clinical attachment loss and amount of keratinized tissue at extraction site were identified as determinants of ridge height outcome. Buccal plate thickness and tooth root length were identified as determinants of ridge width outcome. In addition, initial ridge width was positively correlated with ridge width loss. Micro-CT revealed greater mineralization per unit volume in new bone compared with existing bone in mandible (p < 0.001). Distributions of residual graft, new cellular bone and immature tissue were similar in both jaws. Conclusion Within the limitations of this study, the results indicate that in different anatomic locations different factors may determine ARP outcomes. Further studies are needed to better understand determinants of ARP outcomes. PMID:23432761

  5. Impact of clinical factors on the long-term functional and anatomic outcomes of osteo-odonto-keratoprosthesis and tibial bone keratoprosthesis.

    PubMed

    De La Paz, María Fideliz; De Toledo, Juan Álvarez; Charoenrook, Victor; Sel, Saadettin; Temprano, José; Barraquer, Rafael I; Michael, Ralph

    2011-05-01

    To report the long-term functional and anatomic outcomes of osteo-odonto-keratoprosthesis and tibial bone keratoprosthesis; to analyze the influence of clinical factors, such as surgical technique, primary diagnosis, age, and postoperative complications, on the final outcome. Retrospective cohort study. setting: Centro de Oftalmología Barraquer, between 1974 and 2005. Two hundred twenty-seven patients. intervention: Biological keratoprosthesis using osteo-odonto-keratoprosthesis or tibial bone keratoprosthesis. main outcome measures: Functional survival with success defined as best-corrected visual acuity ≥0.05; anatomic survival with success defined as retention of the keratoprosthesis lamina. Osteo-odonto-keratoprosthesis and tibial bone keratoprosthesis have comparable anatomic survival at 5 and 10 years of follow-up, but osteo-odonto-keratoprosthesis has a significantly better functional success than tibial bone keratoprosthesis at the same time periods. Among the primary diagnoses, Stevens-Johnson syndrome, chemical burn, and trachoma have generally good functional and anatomic outcomes and the least favorable prognosis is for ocular cicatricial pemphigoid. Younger patients fared better than those in older age groups. The most frequent complications were extrusion (28%), retinal detachment (16%), and uncontrolled glaucoma (11%). The glaucoma group had the best anatomic success but the worst functional results, only exceeded by the retinal detachment group in terms of functional outcome. Clinical factors, such as surgical technique, primary diagnosis, age, and postoperative complications, can affect the long-term anatomic and functional successes of biological keratoprosthesis. Knowledge about the impact of each of these factors on survival can help surgeons determine the best approach in every particular case. Copyright © 2011 Elsevier Inc. All rights reserved.

  6. Anatomical factors determining surgical decision-making in patients with transposition of the great arteries with left ventricular outflow tract obstruction.

    PubMed

    Honjo, Osami; Kotani, Yasuhiro; Bharucha, Tara; Mertens, Luc; Caldarone, Christopher A; Redington, Andrew N; Van Arsdell, Glen

    2013-12-01

    Transposition of the great arteries (TGA) and left ventricular outflow tract obstruction (LVOTO) with or without ventricular septal defect have multiple surgical treatment options. We sought to identify pre- and intraoperative factors that determine the timing of repair, procedure type and subsequent LVOT outcome. Twenty-eight (8.2% of all TGA) patients with TGA with LVOTO (double outlet ventricle, n = 5, TGA/intact septum, n = 1) between 2000 and 2012 were reviewed. Anatomical factors were identified by prerepair echocardiography. LVOTO complexity was characterized by the degree of obstruction (0 = none, 0.33 = mild, 0.66 moderate and 1 = severe) at various levels: pulmonary valve (PV) dysplasia/hypoplasia, posterior deviation of the infundibular septum, fibromuscular ridge, tissue tag and abnormal chordal attachment. Summation of the obstruction score, at each level, yielded the LVOT complexity score. The descriptive analysis of intraoperative decision-making at late repair was performed. early arterial switch operation (ASO) + LVOT resection (n = 9, 32%), late ASO + LVOT resection (n = 3, 10%), Nikaidoh (n = 8, 29%), Rastelli (n = 6, 21%), single-ventricle palliation (n = 2, 7%). The primary LVOT obstruction mechanism was posterior deviation of the infundibular septum (n = 16, 57%) and PV dysplasia (n = 6, 21%). The early ASO group had a lower PV complexity score (0.42 ± 0.22 vs 0.96 ± 0.55, P = 0.007), tissue tag score (0.03 ± 0.15 vs 0.26 ± 0.34, P = 0.018) and LVOT complexity score (2.11 ± 0.86 vs 3.2 ± 0.96, P = 0.006). The LVOT complexity score in the Nikaidoh group was higher than in the late ASO group (P = 0.019). Of 16 candidates for the Nikaidoh procedure, 6 patients underwent a Rastelli operation due to coronary artery patterns (single coronary, n = 3, 1RL-2Cx, n = 2 or an abnormal left anterior descending coronary artery course, n = 1). Two patients underwent single-ventricle palliation due to the interference of essential chordae. All patients

  7. Determination of anatomic landmarks for optimal placement in captive-bolt euthanasia of goats.

    PubMed

    Plummer, Paul J; Shearer, Jan K; Kleinhenz, Katie E; Shearer, Leslie C

    2018-03-01

    OBJECTIVE To determine the optimal anatomic site and directional aim of a penetrating captive bolt (PCB) for euthanasia of goats. SAMPLE 8 skulls from horned and polled goat cadavers and 10 anesthetized horned and polled goats scheduled to be euthanized at the end of a teaching laboratory. PROCEDURES Sagittal sections of cadaver skulls from 8 horned and polled goats were used to determine the ideal anatomic site and aiming of a PCB to maximize damage to the midbrain region of the brainstem for euthanasia. Anatomic sites for ideal placement and directional aiming were confirmed by use of 10 anesthetized horned and polled goats. RESULTS Clinical observation and postmortem examination of the sagittal sections of skulls from the 10 anesthetized goats that were euthanized confirmed that perpendicular placement and firing of a PCB at the intersection of 2 lines, each drawn from the lateral canthus of 1 eye to the middle of the base of the opposite ear, resulted in consistent disruption of the midbrain and thalamus in all goats. Immediate cessation of breathing, followed by a loss of heartbeat in all 10 of the anesthetized goats, confirmed that use of this site consistently resulted in effective euthanasia. CONCLUSIONS AND CLINICAL RELEVANCE Damage to the brainstem and key adjacent structures may be accomplished by firing a PCB perpendicular to the skull over the anatomic site identified at the intersection of 2 lines, each drawn from the lateral canthus of 1 eye to the middle of the base of the opposite ear.

  8. Anatomical location of metastatic lymph nodes: an indispensable prognostic factor for gastric cancer patients who underwent curative resection.

    PubMed

    Zhao, Bochao; Zhang, Jingting; Zhang, Jiale; Chen, Xiuxiu; Chen, Junqing; Wang, Zhenning; Xu, Huimian; Huang, Baojun

    2018-02-01

    Although the numeric-based lymph node (LN) staging was widely used in the worldwide, it did not represent the anatomical location of metastatic lymph nodes (MLNs) and not reflect extent of LN dissection. Therefore, in the present study, we investigated whether the anatomical location of MLNs was still necessary to evaluate the prognosis of node-positive gastric cancer (GC) patients. We reviewed 1451 GC patients who underwent radical gastrectomy in our institution between January 1986 and January 2008. All patients were reclassified into several groups according to the anatomical location of MLNs and the number of MLNs. The prognostic differences between different patient groups were compared and clinicopathologic features were analyzed. In the present study, both anatomical location of MLNs and the number of MLNs were identified as the independent prognostic factors (p < .01). The patients with extraperigastric LN involvement showed a poorer prognosis compared with the perigastric-only group (p < .001). For the N1-N2 stage patients, the prognostic discrepancy was still observed among them when the anatomical location of MLNs was considered (p < .05). For the N3-stage patients, although the anatomical location of MLNs had no significant effect on the prognosis of these patients, the higher number of MLNs in the extraperigastric area was correlated with the unfavorable prognosis (p < .05). The anatomical location of MLNs was an important factor influencing the prognostic outcome of GC patients. To provide more accurate prognostic information for GC patients, the anatomical location of MLNs should not be ignored.

  9. Statistical Analyses of Femur Parameters for Designing Anatomical Plates.

    PubMed

    Wang, Lin; He, Kunjin; Chen, Zhengming

    2016-01-01

    Femur parameters are key prerequisites for scientifically designing anatomical plates. Meanwhile, individual differences in femurs present a challenge to design well-fitting anatomical plates. Therefore, to design anatomical plates more scientifically, analyses of femur parameters with statistical methods were performed in this study. The specific steps were as follows. First, taking eight anatomical femur parameters as variables, 100 femur samples were classified into three classes with factor analysis and Q-type cluster analysis. Second, based on the mean parameter values of the three classes of femurs, three sizes of average anatomical plates corresponding to the three classes of femurs were designed. Finally, based on Bayes discriminant analysis, a new femur could be assigned to the proper class. Thereafter, the average anatomical plate suitable for that new femur was selected from the three available sizes of plates. Experimental results showed that the classification of femurs was quite reasonable based on the anatomical aspects of the femurs. For instance, three sizes of condylar buttress plates were designed. Meanwhile, 20 new femurs are judged to which classes the femurs belong. Thereafter, suitable condylar buttress plates were determined and selected.

  10. Procedure Planning: Anatomical Determinants of Strategy

    PubMed Central

    Hanratty, Colm; Walsh, Simon

    2014-01-01

    In contemporary practice there are three main methods that can be employed when attempting to open a chronic total occlusion (CTO) of a coronary artery; antegrade or retrograde wire escalation, antegrade dissection re-entry and retrograde dissection re-entry. This editorial will attempt to clarify the anatomical features that can be identified to help when deciding which of these strategies to employ initially and help understand the reasons for this decision. PMID:24694102

  11. Anatomical predisposing factors of transmural thermal injury after pulmonary vein isolation.

    PubMed

    Kaneshiro, Takashi; Matsumoto, Yoshiyuki; Nodera, Minoru; Kamioka, Masashi; Kamiyama, Yoshiyuki; Yoshihisa, Akiomi; Ohkawara, Hiroshi; Suzuki, Hitoshi; Takeishi, Yasuchika

    2017-06-12

    Transmural thermal injury (TTI), such as oesophageal erosion/ulcer and perioesophageal nerve injury leading to gastric hypomotility, is an important complication associated with pulmonary vein isolation (PVI). However, a predictor of TTI concerning anatomical structures surrounding the oesophagus has not yet been fully elucidated. Therefore, we sought to identify the predisposing factors of TTI after PVI. Consecutive 110 patients, who underwent PVI for atrial fibrillation, received oesophagogastroduodenoscopy 2 days later, were investigated. The relationships between TTI and clinical and anatomical parameters were examined. Based on the computed tomography data, we measured the angle of the left atrial (LA) posterior wall to the descending aorta (Ao) (LA-Ao angle), the branching angle of the left inferior pulmonary vein (LIPV) to the coronal plane (LIPV angle), and the minimum distance between the LA posterior wall and descending Ao enclosing the oesophagus (LA-Ao distance). Transmural thermal injuries occurred in 21 patients (oesophageal erosion in 5 and gastric hypomotility in 16). Age, gender, body mass index, LA diameter, and LA volume index in echocardiography were not associated with TTI. However, the LIPV angle was larger and the LA-Ao distance was shorter in the TTI (+) group compared to the TTI (-) group. With multivariate logistic regression analysis, the LIPV angle [odds ratio (OR): 2.144, P = 0.0031] and LA-Ao distance (OR: 0.392, P = 0.0229) were independent predictors of TTI. The anatomical proximities of the LA posterior wall, LIPV, and descending Ao surrounding the oesophagus are strongly associated with the prevalence of TTI. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.

  12. Comparison of survival outcomes after anatomical resection and non-anatomical resection in patients with hepatocellular carcinoma

    PubMed Central

    Kim, Seheon; Kim, Seokwhan; Song, Insang

    2015-01-01

    Backgrounds/Aims Liver resection is a curative procedure performed worldwide for hepatocellular carcinoma (HCC). Deciding on the appropriate resection range for postoperative hepatic function preservation is an important surgical consideration. This study compares survival outcomes of HCC patients who underwent anatomical or non-anatomical resection, to determine which offers the best clinical survival benefit. Methods One hundred and thirty-one patients underwent liver resection with HCC, between January 2007 and February 2015, and were divided into two groups: those who underwent anatomical liver resection (n=88) and those who underwent non-anatomical liver resection (n=43). Kaplan-Meier survival analysis and Cox regressions were used to compare the disease-free survival (DFS) and overall survival (OS) rates between the groups. Results The mean follow-up periods were 27 and 40 months in the anatomical and non-anatomical groups, respectively (p=0.229). The 3- and 5-year DFS rates were 70% and 60% in the anatomical group and 62% and 48% in the non-anatomical group, respectively. The 3 and 5-year OS rates were 94% and 78% in the anatomical group, and 86% and 80% in the non-anatomical group, respectively. The anatomical group tended to show better outcomes, but the findings were not significant. However, a relative risk of OS between the anatomical and non-anatomical group was 0.234 (95% CI, 0.061-0.896; p=0.034), which is statistically significant. Conclusions Although statistical significance was not detected in survival curves, anatomical resection showed better results. In this respect, anatomical resection is more likely to perform in HCC patients with preserve liver function than non-anatomical resection. PMID:26693235

  13. An arthroscopic evaluation of the anatomical "critical zone".

    PubMed

    Naidoo, N; Lazarus, L; Osman, S A; Satyapal, K S

    2017-01-01

    The "critical zone", a region of speculated vascularity, is situated approximately 10 mm proximal to the insertion of the supraspinatus tendon. Despite its obvious role as an anatomical landmark demarcator, its patho-anatomic nature has been identified as the source of rotator cuff pathology. Although many studies have attempted to evaluate the vascularity of this region, the architecture regarding the exact length, width and shape of the critical zone, remains unreported. This study aimed to determine the shape and morphometry of the "critical zone" arthroscopically. The sample series, which was comprised of 38 cases (n = 38) specific to pathological types, employed an anatomical investigation of the critical zone during routine real-time arthroscopy. Demographic representation: i) sex: 19 males, 19 females; ii) age range: 18-76 years; iii) race: white (n = 29), Indian (n = 7) and coloured (n = 2). The incidence of shape and the mean lengths and widths of the critical zone were determined in accordance with the relevant demographic factors and patient history. Although the cresenteric shape was predominant, hemispheric and sail-shaped critical zones were also identified. The lengths and widths of the critical zone appeared markedly increased in male individuals. While the increase in age may account for the increased incidence of rotator cuff degeneration due to poor end-vascular supply, the additional factors of height and weight presented as major determinants of the increase in size of the critical zone. In addition, the comparisons of length and width with each other and shape yielded levels of significant difference, therefore indicating a directly proportional relationship between the length and width of the critical zone. This detailed understanding of the critical zone may prove beneficial for the success of post-operative rotator cuff healing.

  14. CT imaging-based determination and classification of anatomic variations of left gastric vein.

    PubMed

    Wu, Yongyou; Chen, Guangqiang; Wu, Pengfei; Zhu, Jianbin; Peng, Wei; Xing, Chungen

    2017-03-01

    Precise determination and classification of left gastric vein (LGV) anatomy are helpful in planning for gastric surgery, in particular, for resection of gastric cancer. However, the anatomy of LGV is highly variable. A systematic classification of its variations is still to be proposed. We aimed to investigate the anatomical variations in LGV using CT imaging and develop a new nomenclature system. We reviewed CT images and tracked the course of LGV in 825 adults. The frequencies of common and variable LGV anatomical courses were recorded. Anatomic variations of LGV were proposed and classified into different types mainly based on its courses. The inflow sites of LGV into the portal system were also considered if common hepatic artery (CHA) or splenic artery (SA) could not be used as a frame of reference due to variations. Detailed anatomy and courses of LGV were depicted on CT images. Using CHA and SA as the frames of reference, the routes of LGV were divided into six types (i.e., PreS, RetroS, Mid, PreCH, RetroCH, and Supra). The inflow sites were classified into four types (i.e., PV, SV, PSV, and LPV). The new classification was mainly based on the courses of LGV, which was validated with MDCT in the 805 cases with an identifiable LGV, namely type I, RetroCH, 49.8 % (401/805); type II, PreS, 20.6 % (166/805); type III, Mid, 20.0 % (161/805); type IV, RetroS, 7.3 % (59/805); type V, Supra, 1.5 % (12/805); and type VI, PreCH, 0.7 % (6/805). Type VII, designated to the cases in which SA and CHA could not be used as frames of reference, was not observed in this series. Detailed depiction of the anatomy and courses of LGV on CT images allowed us to evaluate and develop a new classification and nomenclature system for the anatomical variations of LGV.

  15. Anatomical versus non-anatomical single bundle anterior cruciate ligament reconstruction: a cadaveric study of comparison of knee stability.

    PubMed

    Lim, Hong-Chul; Yoon, Yong-Cheol; Wang, Joon-Ho; Bae, Ji-Hoon

    2012-12-01

    The purpose of this study was to compare the initial stability of anatomical and non-anatomical single bundle anterior cruciate ligament (ACL) reconstruction and to determine which would better restore intact knee kinematics. Our hypothesis was that the initial stability of anatomical single bundle ACL reconstruction would be superior to that of non-anatomical single bundle ACL reconstruction. Anterior tibial translation (ATT) and internal rotation of the tibia were measured with a computer navigation system in seven pairs of fresh-frozen cadaveric knees under two testing conditions (manual maximum anterior force, and a manual maximum anterior force combined with an internal rotational force). Tests were performed at 0, 30, 60, and 90 degrees of flexion with the ACL intact, the ACL transected, and after reconstruction of one side of a pair with either anatomical or non-anatomical single bundle ACL reconstruction. Under manual maximal anterior force, both reconstruction techniques showed no significant difference of ATT when compared to ACL intact knee state at 30° of knee flexion (p > 0.05). Under the combined anterior and internal rotatory force, non-anatomical single-bundle ACL reconstruction showed significant difference of ATT compared to those in ACL intact group (p < 0.05). In contrast, central anatomical single bundle ACL reconstruction showed no significant difference of ATT compared to those in ACL intact group (p > 0.05). Internal rotation of the tibia showed no significant difference in the ACL intact, the ACL transected, non-anatomical reconstructed and anatomical reconstructed knees. Anatomical single bundle ACL reconstruction restored the initial stability closer to the native ACL under combined anterior and internal rotational forces when compared to non-anatomical ACL single bundle reconstruction.

  16. The linguistic roots of Modern English anatomical terminology.

    PubMed

    Turmezei, Tom D

    2012-11-01

    Previous research focusing on Classical Latin and Greek roots has shown that understanding the etymology of English anatomical terms may be beneficial for students of human anatomy. However, not all anatomical terms are derived from Classical origins. This study aims to explore the linguistic roots of the Modern English terminology used in human gross anatomy. By reference to the Oxford English Dictionary, etymologies were determined for a lexicon of 798 Modern English gross anatomical terms from the 40(th) edition of Gray's Anatomy. Earliest traceable language of origin was determined for all 798 terms; language of acquisition was determined for 747 terms. Earliest traceable languages of origin were: Classical Latin (62%), Classical Greek (24%), Old English (7%), Post-Classical Latin (3%), and other (4%). Languages of acquisition were: Classical Latin (42%), Post-Classical Latin (29%), Old English (8%), Modern French (6%), Classical Greek (5%), Middle English (3%), and other (7%). While the roots of Modern English anatomical terminology mostly lie in Classical languages (accounting for the origin of 86% of terms), the anatomical lexicon of Modern English is actually much more diverse. Interesting and perhaps less familiar examples from these languages and the methods by which such terms have been created and absorbed are discussed. The author suggests that awareness of anatomical etymologies may enhance the enjoyment and understanding of human anatomy for students and teachers alike. Copyright © 2012 Wiley Periodicals, Inc.

  17. Role of Anatomic and Salivary Factors in Dental Calculus Formation in Primary and Mixed Dentition Stages.

    PubMed

    Afshar, Hossein; Ghandehari, Mehdi; Khorsand, Afshin; Ansari, Ghassem; Nahvi, Azam; Baniameri, Zahra

    2016-01-01

    Clinical experience shows that formation of calculus is a very rare phenomenon in primary teeth, but it increases as the permanent teeth erupt. The purpose of this study was to assess the relationship between dental calculus, dental anatomy, and salivary factors in primary and mixed dentition stages. A cross-sectional study was carried out to determine the buccolingual dimensions of the most concave and the most convex surfaces of the lingual aspect of mandibular central incisor crowns in a sample group of 120 three- to five-old children and 120 eight- to 10-year old children. Saliva samples were collected from 20 in each group. Data were analyzed using t tests. Significant differences were found between the ratio of the buccolingual dimensions of the most convex to the most concave areas of the lingual surfaces in primary and permanent incisors (P=0.028). Saliva analysis revealed significant differences in total protein (P=0.002), sodium (P=0.037), bicarbonate (P=0.003), and ammonia (P=0.025) between the two age groups. Anatomic and salivary factors may be important reasons for the differences in calculus formation.

  18. Anatomical variation of mesophyll conductance under potassium deficiency has a vital role in determining leaf photosynthesis.

    PubMed

    Lu, Zhifeng; Lu, Jianwei; Pan, Yonghui; Lu, Piaopiao; Li, Xiaokun; Cong, Rihuan; Ren, Tao

    2016-11-01

    Leaves exposed to potassium (K) deficiency usually present decreased mesophyll conductance (g m ) and photosynthesis (A). The relative contributions of leaf anatomical traits in determining g m have been quantified; however, anatomical variabilities related to low g m under K starvation remain imperfectly known. A one-dimensional model was used to quantify anatomical controls of the entire CO 2 diffusion pathway resistance within a leaf on two Brassica napus L. cultivars in response to K deficiency. Leaf photosynthesis of both cultivars was significantly decreased under K deficiency in parallel with down-regulated g m . The mesophyll conductance limitation contributed to more than one-half of A decline. The decreased internal air space in K-starved leaves was associated with the increase of gas-phase resistance. Potassium deficiency reduced liquid-phase conductance by decreasing the exposed surface area of chloroplasts per unit leaf area (S c /S), and enlarging the resistance of the cytoplasm that can be interpreted by the increasing distance of chloroplast from cell wall, and between adjacent chloroplasts. Additionally, the discrepancies of A between two cultivars were in part because of g m variations, ascribing to an altered S c /S. These results emphasize the important role of K on the regulation of g m by enhancing S c /S and reducing cytoplasm resistance. © 2016 John Wiley & Sons Ltd.

  19. Adverse cardiac events in 56,000 orthopaedic trauma patients: Does anatomic area make a difference?

    PubMed

    Lee, Adam K; Dodd, Ashley C; Lakomkin, Nikita; Yarlagadda, Mahesh; Jahangir, A Alex; Collinge, Cory A; Sethi, Manish K

    2016-08-01

    Postoperative cardiac events in orthopaedic trauma patients constitute severe morbidity and mortality. It is therefore increasingly important to determine patient risk factors that are predictive of postoperative myocardial infarctions and cardiac arrests. This study sought to assess if there is an association between anatomic area and cardiac complications in the orthopaedic trauma patient. From 2006-2013, a total of 361,402 orthopaedic patients were identified in the NSQIP database using Current Procedural Terminology (CPT) codes. Of these, 56,336 (15.6%) patients were identified as orthopaedic trauma patients broken down by anatomic region: 11,905 (21.1%) upper extremity patients (UE), 29,009 (51.5%) hip/pelvis patients (HP), and 15,422 (27.4%) lower extremity patients (LE) using CPT codes. Patients were defined as having adverse cardiac events if they developed myocardial infarctions or cardiac arrests within 30days after surgery. Chi-squared analysis was used to determine if there was an association between anatomic area and rates of cardiac events. Multivariate logistical analysis was used with over 40 patient characteristics including age, gender, history of cardiac disease, and anatomic region as independent predictors to determine whether anatomic area significantly predicted the development of cardiac complications. There were significant differences in baseline demographics among the three groups: HP patients had the greatest average age (77.6 years) compared to 54.8 years for UE patients and 54.1 years in LE patients (p<0.001). HP patients also had the highest average ASA score (3.0) (p<0.001). There was a significant difference in adverse cardiac events based on anatomic area: 0.27% (32/11,905) UE patients developed cardiac complications compared to 2.15% (623/29,009) HP patients and 0.61% (94/15,422) LE patients. After multivariate analysis, HP patients were significantly more likely to develop cardiac complications compared to both UE patients (OR: 6

  20. Femoral anatomical frame: assessment of various definitions.

    PubMed

    Della Croce, U; Camomilla, V; Leardini, A; Cappozzo, A

    2003-06-01

    The reliability of the estimate of joint kinematic variables and the relevant functional interpretation are affected by the uncertainty with which bony anatomical landmarks and underlying bony segment anatomical frames are determined. When a stereo-photogrammetric system is used for in vivo studies, minimising and compensating for this uncertainty is crucial. This paper deals with the propagation of the errors associated with the location of both internal and palpable femoral anatomical landmarks to the estimation of the orientation of the femoral anatomical frame and to the knee joint angles during movement. Given eight anatomical landmarks, and the precision with which they can be identified experimentally, 12 different rules were defined for the construction of the anatomical frame and submitted to comparative assessment. Results showed that using more than three landmarks allows for more repeatable anatomical frame orientation and knee joint kinematics estimation. Novel rules are proposed that use optimization algorithms. On the average, the femoral frame orientation dispersion had a standard deviation of 2, 2.5 and 1.5 degrees for the frontal, transverse, and sagittal plane, respectively. However, a proper choice of the relevant construction rule allowed for a reduction of these inaccuracies in selected planes to 1 degrees rms. The dispersion of the knee adduction-abduction and internal-external rotation angles could also be limited to 1 degrees rms irrespective of the flexion angle value.

  1. Anatomical accuracy of brain connections derived from diffusion MRI tractography is inherently limited.

    PubMed

    Thomas, Cibu; Ye, Frank Q; Irfanoglu, M Okan; Modi, Pooja; Saleem, Kadharbatcha S; Leopold, David A; Pierpaoli, Carlo

    2014-11-18

    Tractography based on diffusion-weighted MRI (DWI) is widely used for mapping the structural connections of the human brain. Its accuracy is known to be limited by technical factors affecting in vivo data acquisition, such as noise, artifacts, and data undersampling resulting from scan time constraints. It generally is assumed that improvements in data quality and implementation of sophisticated tractography methods will lead to increasingly accurate maps of human anatomical connections. However, assessing the anatomical accuracy of DWI tractography is difficult because of the lack of independent knowledge of the true anatomical connections in humans. Here we investigate the future prospects of DWI-based connectional imaging by applying advanced tractography methods to an ex vivo DWI dataset of the macaque brain. The results of different tractography methods were compared with maps of known axonal projections from previous tracer studies in the macaque. Despite the exceptional quality of the DWI data, none of the methods demonstrated high anatomical accuracy. The methods that showed the highest sensitivity showed the lowest specificity, and vice versa. Additionally, anatomical accuracy was highly dependent upon parameters of the tractography algorithm, with different optimal values for mapping different pathways. These results suggest that there is an inherent limitation in determining long-range anatomical projections based on voxel-averaged estimates of local fiber orientation obtained from DWI data that is unlikely to be overcome by improvements in data acquisition and analysis alone.

  2. Does the anatomical localization of lower extremity venous diseases affect the quality of life?

    PubMed

    Sadikoglu, Ganime; Ozcakir, Alis; Ercan, Ilker; Yildiz, Caner; Sadikoglu, Yurtkuran

    2006-11-01

    To investigate the effects of venous diseases at different anatomical localizations on the qualities of life of patients with varicose veins. The study included 354 cases, which was referred to a private vascular and interventional radiology center in Bursa, Turkey between January 2005 to January 2006. The cases were diagnosed with visual inspection and were clinically indicative of varicose veins. Color Doppler ultrasonography was used to radiologically examine the varicose veins. All cases were accepted as class II criteria according to the Clinical, Etiologic, Anatomic, Pathophysiologic classification. The generic Short Form Health Survey-36 (SF-36) was used to measure physical and mental quality of life (QOL). High scores indicated good QOL. The Statistical Package for Social Sciences version 13.0 program was used for the statistical evaluation. When the life SF-36 quality parameters of cases with different anatomical localizations of the varicose veins were examined, only the mental health scores were found to differ in different groups (p<0.01). In females and males with superficial venous disease, significant differences were found in physical function, physical role and pain among the physical health scale components, and in vitality and emotional role scores among the mental state determinants. When females and males with deep vein disease were compared, significant differences were found among both physical and mental health determinants. Anatomical localization of lower extremity varicose veins can be accepted as a predictive factor in determining the life qualities of patients with varicosities in their lower limb, and should be used to regulate their therapy and follow up protocols.

  3. Ageing introduces a complex pattern of changes in several rat brain transcription factors depending on gender and anatomical localization.

    PubMed

    Sanguino, Elena; Roglans, Núria; Rodríguez-Calvo, Ricardo; Alegret, Marta; Sánchez, Rosa M; Vázquez-Carrera, Manuel; Laguna, Juan C

    2006-04-01

    As ageing changes the activity of several transcription factors in the rat cortex, we were interested in determining whether similar changes also appear in the hippocampus of old rats. We determined by electrophoretic gel shift assays the binding activity of nuclear factor kappa B (NFkappaB), activator protein-1 (AP-1), peroxisome proliferator-activated receptor (PPAR), and liver X receptor (LXR) in cortex and hippocampus samples from young (3-month-old), and old (18-month-old) male and female Sprague-Dawley rats. NFkappaB activity increased in old male and female rats, though only in cortex samples, while AP-1 activity decreased only in the cortex and hippocampus of old female animals. LXR activity decreased in all conditions, except in old male cortexes; whereas PPAR activity only decreased in the hippocampus of old female rats. Decreases in AP-1 and PPAR activities restricted to old female rats did not result from an age-related decline in plasma 17beta-estradiol concentration, as their activities did not change in samples obtained from ovariectomized young female rats. Our results indicate that ageing induces a complex pattern of changes in the brain-binding activity of NFkappaB, AP-1, PPAR and LXR, depending on the anatomical origin of the samples (cortex or hippocampus), and the sex of the animals studied.

  4. Anatomically contoured plates for fixation of rib fractures.

    PubMed

    Bottlang, Michael; Helzel, Inga; Long, William B; Madey, Steven

    2010-03-01

    : Intraoperative contouring of long bridging plates for stabilization of flail chest injuries is difficult and time consuming. This study implemented for the first time biometric parameters to derive anatomically contoured rib plates. These plates were tested on a range of cadaveric ribs to quantify plate fit and to extract a best-fit plating configuration. : Three left and three right rib plates were designed, which accounted for anatomic parameters required when conforming a plate to the rib surface. The length lP over which each plate could trace the rib surface was evaluated on 109 cadaveric ribs. For each rib level 3-9, the plate design with the highest lP value was extracted to determine a best-fit plating configuration. Furthermore, the characteristic twist of rib surfaces was measured on 49 ribs to determine the surface congruency of anatomic plates with a constant twist. : The tracing length lP of the best-fit plating configuration ranged from 12.5 cm to 14.7 cm for ribs 3-9. The corresponding range for standard plates was 7.1-13.7 cm. The average twist of ribs over 8-cm, 12-cm, and 16-cm segments was 8.3 degrees, 20.6 degrees, and 32.7 degrees, respectively. The constant twist of anatomic rib plates was not significantly different from the average rib twist. : A small set of anatomic rib plates can minimize the need for intraoperative plate contouring for fixation of ribs 3-9. Anatomic rib plates can therefore reduce the time and complexity of flail chest stabilization and facilitate spanning of flail segments with long plates.

  5. Chinook wind barosinusitis: an anatomic evaluation.

    PubMed

    Rudmik, Luke; Muzychuk, Adam; Oddone Paolucci, Elizabeth; Mechor, Brad

    2009-01-01

    Chinook, or föhn, is a weather phenomenon characterized by a rapid influx of warm, high-pressured winds into a specific location. Pressure changes associated with chinook winds induce facial pain similar to acute sinusitis. The purpose of this study was to determine the relationship between sinonasal anatomy and chinook headaches. Retrospective computed tomography (CT) sinonasal anatomy analysis of 38 patients with chinook headaches and 27 controls (no chinook headaches). The chinook headache status was blinded from the CT reviewer. Forty-one sinonasal anatomy variants, Lund-Mackay status, and sinus size (cm(3)) were recorded. There were three statistically significant sinonasal anatomy differences between patients with and without chinook headaches. The presence of a concha bullosa and sphenoethmoidal cell (Onodi cell) appeared to predispose to chinook headaches (p = 0.004). Chinook headache patients had larger maxillary sinus size (right, p = 0.015, and left, p = 0.002). The Lund-Mackay score was higher in the control patients (p = 0.003) indicating that chronic sinusitis does not play a role in chinook headaches. Chinook winds are a common source of facial pain and pressure. This is the first study to show that sinonasal anatomic variations may be a predisposing factor. Anatomic variants may induce facial pain by blocking the natural sinus ostia, thus preventing adequate pressure equilibrium.

  6. Leaf anatomical traits determine the 18O enrichment of leaf water in coastal halophytes

    NASA Astrophysics Data System (ADS)

    Liang, J.; Lin, G., Sr.; Sternberg, L. O.

    2017-12-01

    Foliar anatomical adaptations to high-salinity environment in mangroves may be recorded by leaf water isotopes. Recent studies observed that a few mangrove species have lower 18O enrichment of leaf water (ΔL) relative to source water than the adjacent terrestrial trees, but what factors actually control this phenomenon is still disputable at present. To resolve this issue, we collected 15 species of true mangrove plants, 14 species of adjacent freshwater trees and 4 species of semi-mangrove plants at five study sites on the southeastern coast of China. Leaf stomatal density and pore size, water content, ΔL and other related leaf physiological traits were determined for the selected leaves of these plants. Our results confirmed that ΔL values of mangroves were generally 3 4 ‰ lower than those of the adjacent freshwater or semi-mangrove species. Higher leaf water per area (LWC) and lower leaf stomatal density (LS) of mangroves played co-dominant roles in lowering ΔL through elongating effective leaf mixing length by about 20%. The Péclet model incorporated by LWC and LS performed well in predicting ΔL. The demonstrated general law between leaf anatomy and ΔL in this paper based on a large pool of species bridges the gap between leaf functional traits and metabolic proxies derived ΔL, which will have considerable potential applications in vegetation succession and reconstruction of paleoclimate research.

  7. Acoustical and anatomical determination of sound production and transmission in West Indian (Trichechus manatus) and Amazonian (T. inunguis) manatees.

    PubMed

    Landrau-Giovannetti, Nelmarie; Mignucci-Giannoni, Antonio A; Reidenberg, Joy S

    2014-10-01

    West Indian (Trichechus manatus) and Amazonian (T. inunguis) manatees are vocal mammals, with most sounds produced for communication between mothers and calves. While their hearing and vocalizations have been well studied, the actual mechanism of sound production is unknown. Acoustical recordings and anatomical examination were used to determine the source of sound generation. Recordings were performed on live captive manatees from Puerto Rico, Cuba and Colombia (T. manatus) and from Peru (T. inunguis) to determine focal points of sound production. The manatees were recorded using two directional hydrophones placed on the throat and nasal region and an Edirol-R44 digital recorder. The average sound intensity level was analyzed to evaluate the sound source with a T test: paired two sample for means. Anatomical examinations were conducted on six T. manatus carcasses from Florida and Puerto Rico. During necropsies, the larynx, trachea, and nasal areas were dissected, with particular focus on identifying musculature and soft tissues capable of vibrating or constricting the airway. From the recordings we found that the acoustical intensity was significant (P < 0.0001) for both the individuals and the pooled manatees in the ventral throat region compared to the nasal region. From the dissection we found two raised areas of tissue in the lateral walls of the manatee's laryngeal lumen that are consistent with mammalian vocal folds. They oppose each other and may be able to regulate airflow between them when they are adducted or abducted by muscular control of arytenoid cartilages. Acoustic and anatomical evidence taken together suggest vocal folds as the mechanism for sound production in manatees. © 2014 Wiley Periodicals, Inc.

  8. Development of a femoral template for computer-assisted tunnel placement in anatomical double-bundle ACL reconstruction.

    PubMed

    Luites, J W H; Wymenga, A B; Blankevoort, L; Kooloos, J M G; Verdonschot, N

    2011-01-01

    Femoral graft placement is an important factor in the success of anterior cruciate ligament (ACL) reconstruction. In addition to improving the accuracy of femoral tunnel placement, Computer Assisted Surgery (CAS) can be used to determine the anatomic location. This is achieved by using a 3D femoral template which indicates the position of the anatomical ACL center based on endoscopically measurable landmarks. This study describes the development and application of this method. The template is generated through statistical shape analysis of the ACL insertion, with respect to the anteromedial (AM) and posterolateral (PL) bundles. The ligament insertion data, together with the osteocartilage edge on the lateral notch, were mapped onto a cylinder fitted to the intercondylar notch surface (n = 33). Anatomic variation, in terms of standard variation of the positions of the ligament centers in the template, was within 2.2 mm. The resulting template was programmed in a computer-assisted navigation system for ACL replacement and its accuracy and precision were determined on 31 femora. It was found that with the navigation system the AM and PL tunnels could be positioned with an accuracy of 2.5 mm relative to the anatomic insertion centers; the precision was 2.4 mm. This system consists of a template that can easily be implemented in 3D computer navigation software. Requiring no preoperative images and planning, the system provides adequate accuracy and precision to position the entrance of the femoral tunnels for anatomical single- or double-bundle ACL reconstruction.

  9. Anatomic factors related to the cause of tennis elbow.

    PubMed

    Bunata, Robert E; Brown, David S; Capelo, Roderick

    2007-09-01

    The pathogenesis of lateral epicondylitis remains unclear. Our purpose was to study the anatomy of the lateral aspect of the elbow under static and dynamic conditions in order to identify bone-to-tendon and tendon-to-tendon contact or rubbing that might cause abrasion of the tissues. Eighty-five cadaveric elbows were examined to determine details related to the bone structure and musculotendinous origins. We identified the relative positions of the musculotendinous units and the underlying bone when the elbow was in different degrees of flexion. We also recorded the contact between the extensor carpi radialis brevis and the lateral edge of the capitellum as elbow motion occurred, and we sought to identify the areas of the capitellum and extensor carpi radialis brevis where contact occurs. The average site of origin of the extensor carpi radialis brevis on the humerus lay slightly medial and superior to the outer edge of the capitellum. As the elbow was extended, the undersurface of the extensor carpi radialis brevis rubbed against the lateral edge of the capitellum while the extensor carpi radialis longus compressed the brevis against the underlying bone. The extensor carpi radialis brevis tendon has a unique anatomic location that makes its undersurface vulnerable to contact and abrasion against the lateral edge of the capitellum during elbow motion.

  10. Genetic determinism of anatomical and hydraulic traits within an apple progeny.

    PubMed

    Lauri, Pierre-Éric; Gorza, Olivier; Cochard, Hervé; Martinez, Sébastien; Celton, Jean-Marc; Ripetti, Véronique; Lartaud, Marc; Bry, Xavier; Trottier, Catherine; Costes, Evelyne

    2011-08-01

    The apple tree is known to have an isohydric behaviour, maintaining rather constant leaf water potential in soil with low water status and/or under high evaporative demand. However, little is known on the xylem water transport from roots to leaves from the two perspectives of efficiency and safety, and on its genetic variability. We analysed 16 traits related to hydraulic efficiency and safety, and anatomical traits in apple stems, and the relationships between them. Most variables were found heritable, and we investigated the determinism underlying their genetic control through a quantitative trait loci (QTL) analysis on 90 genotypes from the same progeny. Principal component analysis (PCA) revealed that all traits related to efficiency, whether hydraulic conductivity, vessel number and area or wood area, were included in the first PC, whereas the second PC included the safety variables, thus confirming the absence of trade-off between these two sets of traits. Our results demonstrated that clustered variables were characterized by common genomic regions. Together with previous results on the same progeny, our study substantiated that hydraulic efficiency traits co-localized with traits identified for tree growth and fruit production. © 2011 Blackwell Publishing Ltd.

  11. Enhanced anatomical calibration in human movement analysis.

    PubMed

    Donati, Marco; Camomilla, Valentina; Vannozzi, Giuseppe; Cappozzo, Aurelio

    2007-07-01

    The representation of human movement requires knowledge of both movement and morphology of bony segments. The determination of subject-specific morphology data and their registration with movement data is accomplished through an anatomical calibration procedure (calibrated anatomical systems technique: CAST). This paper describes a novel approach to this calibration (UP-CAST) which, as compared with normally used techniques, achieves better repeatability, a shorter application time, and can be effectively performed by non-skilled examiners. Instead of the manual location of prominent bony anatomical landmarks, the description of which is affected by subjective interpretation, a large number of unlabelled points is acquired over prominent parts of the subject's bone, using a wand fitted with markers. A digital model of a template-bone is then submitted to isomorphic deformation and re-orientation to optimally match the above-mentioned points. The locations of anatomical landmarks are automatically made available. The UP-CAST was validated considering the femur as a paradigmatic case. Intra- and inter-examiner repeatability of the identification of anatomical landmarks was assessed both in vivo, using average weight subjects, and on bare bones. Accuracy of the identification was assessed using the anatomical landmark locations manually located on bare bones as reference. The repeatability of this method was markedly higher than that reported in the literature and obtained using the conventional palpation (ranges: 0.9-7.6 mm and 13.4-17.9, respectively). Accuracy resulted, on average, in a maximal error of 11 mm. Results suggest that the principal source of variability resides in the discrepancy between subject's and template bone morphology and not in the inter-examiner differences. The UP-CAST anatomical calibration could be considered a promising alternative to conventional calibration contributing to a more repeatable 3D human movement analysis.

  12. Anatomical Data for Analyzing Human Motion.

    ERIC Educational Resources Information Center

    Plagenhoef, Stanley; And Others

    1983-01-01

    Anatomical data obtained from cadavers and from water displacement studies with living subjects were used to determine the weight, center of gravity, and radius of gyration for 16 body segments. A lead model was used to study movement patterns of the trunk section of the body. (Authors/PP)

  13. Anatomical variations and sinusitis.

    PubMed

    Jorissen, M; Hermans, R; Bertrand, B; Eloy, P

    1997-01-01

    Paranasal sinus anatomy and variations have gained interest with the introduction of functional endoscopic sinus surgery and the concept of the ostiomeatal complex. Anatomical variations can be divided in structural abnormalities, (increased) pneumatization and supplementary openings. Most anatomical variations are equally found in control and sinusitis patients. The anatomical variations which are most commonly associated with sinus pathology are septal deviations, true conchae bullosae and supplementary maxillary ostia but the latter one only when recycling is present. The knowledge of anatomical variations is most important in the surgical management and specifically in the prevention of complications.

  14. Pregnancy outcomes among patients with recurrent pregnancy loss and uterine anatomic abnormalities.

    PubMed

    Gabbai, Daniel; Harlev, Avi; Friger, Michael; Steiner, Naama; Sergienko, Ruslan; Kreinin, Andrey; Bashiri, Asher

    2017-07-25

    Different etiologies for recurrent pregnancy loss have been identified, among them are: anatomical, endocrine, genetic, chromosomal and thrombophilia pathologies. To assess medical and obstetric characteristics, and pregnancy outcomes, among women with uterine abnormalities and recurrent pregnancy loss (RPL). This study also aims to assess the impact of uterine anatomic surgical correction on pregnancy outcomes. A retrospective case control study of 313 patients with two or more consecutive pregnancy losses followed by a subsequent (index) pregnancy. Anatomic abnormalities were detected in 80 patients. All patients were evaluated and treated in the RPL clinic at Soroka University Medical Center. Out of 80 patients with uterine anatomic abnormalities, 19 underwent surgical correction, 32 did not and 29 had no clear record of surgical intervention, and thus were excluded from this study. Women with anatomic abnormalities had a higher rate of previous cesarean section (18.8% vs. 8.6%, P=0.022), tended to have a lower number of previous live births (1.05 vs. 1.37, P=0.07), and a higher rate of preterm delivery (22.9% vs. 10%, P=0.037). Using multivariate logistic regression analysis, anatomic abnormality was identified as an independent risk factor for RPL in patients with previous cesarean section after controlling for place of residence, positive genetic/autoimmune/endocrine workup, and fertility problems (OR 7.22; 95% CI 1.17-44.54, P=0.03). Women suffering from anatomic abnormalities tended to have a higher rate of pregnancy loss compared to those without anatomic abnormalities (40% vs. 30.9%, P=0.2). The difference in pregnancy loss rate among women who underwent surgical correction compared to those who did not was not statistically significant. In patients with previous cesarean section, uterine abnormality is an independent risk factor for pregnancy loss. Surgical correction of uterine abnormalities among RPL patients might have the potential to improve live

  15. Influencing factors on CPAP adherence and anatomic characteristics of upper airway in OSA subjects.

    PubMed

    Park, Pona; Kim, Jinil; Song, Yoon Jae; Lim, Jae Hyun; Cho, Sung Woo; Won, Tae-Bin; Han, Doo Hee; Kim, Dong-Young; Rhee, Chae Seo; Kim, Hyun Jik

    2017-12-01

    Although continuous positive airway pressure (CPAP) is the most effective treatment modality, poor adherence still remains a problem for obstructive sleep apnea (OSA) treatment and there is little evidence regarding how this might be improved. This study aims to analyze the anatomic and clinical factors of OSA subjects who failed to comply with CPAP therapy.The medical records of 47 OSA subjects who received CPAP therapy as a first-line treatment modality were retrospectively reviewed. The medical records were reviewed for demographic and polysomnographic data and anatomic findings of the nasal cavity and oropharynx.24 patients who adhered to CPAP therapy and 23 patients who were nonadherent were enrolled in the study. There were no statistically significant differences in sleep parameters between CPAP-adherent patients and CPAP nonadherent subjects. Mean body mass index of CPAP nonadherent group was significantly higher than CPAP adherent group. Higher grades of septal deviation and hypertrophic change of the inferior turbinate were observed more in the CPAP nonadherent group. In addition, CPAP nonadherent subjects showed considerably bigger tonsils and higher grade palatal position comparing with the CPAP adherent subjects. Subjective discomfort including inconvenience, mouth dryness, and chest discomfort were the main problems for OSA subjects who did not comply with CPAP therapy.Excessive upper airway blockage in the nasal cavity and oropharynx was predominant in CPAP nonadherent subjects, which might cause the reported subjective discomfort that reduces CPAP compliance. Therefore, resolution of these issues is needed to enhance CPAP compliance for control of OSA. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.

  16. Influencing factors on CPAP adherence and anatomic characteristics of upper airway in OSA subjects

    PubMed Central

    Park, Pona; Kim, Jinil; Song, Yoon Jae; Lim, Jae Hyun; Cho, Sung Woo; Won, Tae-Bin; Han, Doo Hee; Kim, Dong-Young; Rhee, Chae Seo; Kim, Hyun Jik

    2017-01-01

    Abstract Although continuous positive airway pressure (CPAP) is the most effective treatment modality, poor adherence still remains a problem for obstructive sleep apnea (OSA) treatment and there is little evidence regarding how this might be improved. This study aims to analyze the anatomic and clinical factors of OSA subjects who failed to comply with CPAP therapy. The medical records of 47 OSA subjects who received CPAP therapy as a first-line treatment modality were retrospectively reviewed. The medical records were reviewed for demographic and polysomnographic data and anatomic findings of the nasal cavity and oropharynx. 24 patients who adhered to CPAP therapy and 23 patients who were nonadherent were enrolled in the study. There were no statistically significant differences in sleep parameters between CPAP-adherent patients and CPAP nonadherent subjects. Mean body mass index of CPAP nonadherent group was significantly higher than CPAP adherent group. Higher grades of septal deviation and hypertrophic change of the inferior turbinate were observed more in the CPAP nonadherent group. In addition, CPAP nonadherent subjects showed considerably bigger tonsils and higher grade palatal position comparing with the CPAP adherent subjects. Subjective discomfort including inconvenience, mouth dryness, and chest discomfort were the main problems for OSA subjects who did not comply with CPAP therapy. Excessive upper airway blockage in the nasal cavity and oropharynx was predominant in CPAP nonadherent subjects, which might cause the reported subjective discomfort that reduces CPAP compliance. Therefore, resolution of these issues is needed to enhance CPAP compliance for control of OSA. PMID:29390419

  17. Impact of Anatomical, Procedural, and Operator Skill Factors on the Success and Duration of Fluoroscopy-Guided Transjugular Intrahepatic Portosystemic Shunt

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marquardt, Steffen, E-mail: marquardt.steffen@mh-hannover.de; Rodt, Thomas, E-mail: rodt.thomas@mh-hannover.de; Rosenthal, Herbert, E-mail: rosenthal.herbert@mh-hannover.de

    PurposeTo assess the impact of anatomical, procedural, and operator skill factors on the success and duration of fluoroscopy-guided transjugular intrahepatic portoystemic shunt following standard operating procedure (SOP).Material and MethodsDuring a 32-month period, 102 patients underwent transjugular intrahepatic portosystemic shunt creation (TIPS) by two interventional radiologists (IR) following our institutional SOP based on fluoroscopy guidance. Both demographic and procedural data were assessed. The duration of the intervention (D{sub Int}) and of the portal vein puncture (D{sub Punct}) was analyzed depending on the skill level of the IR as well as the anatomic or procedural factors.ResultsIn 99 of the 102 patients, successfulmore » TIPS without peri-procedural complications was performed. The mean D{sub Int} (IR1: 77 min; IR2: 51 min, P < 0.005) and the mean D{sub Punct} (IR1: 19 min; IR2: 13 min, P < 0.005) were significantly higher in TIPS performed by IR1 (with 2 years of clinical experience performing TIPS, n = 38) than by IR2 (>10 years of clinical experience performing TIPS, n = 61), (P < 0.005 both, Mann–Whitney U test). D{sub Int} showed a higher correlation with D{sub Punct} for IR2 (R{sup 2} = 0.63) than for IR1 (R{sup 2} = 0.13). There was no significant difference in the D{sub Punct} for both IRs with regard to the success of the wedged portography (P = 0.90), diameter of the portal vein (P = 0.60), central right portal vein length (P = 0.49), or liver function (MELD-Score before the TIPS procedure; P = 0.14).ConclusionTIPS following SOP is safe, fast, and reliable. The only significant factor for shorter D{sub Punct} and D{sub Int} was the clinical experience of the IR. Anatomic variability, successful portography, or liver function did not alter the duration or technical success of TIPS.« less

  18. Standardized anatomic space for abdominal fat quantification

    NASA Astrophysics Data System (ADS)

    Tong, Yubing; Udupa, Jayaram K.; Torigian, Drew A.

    2014-03-01

    The ability to accurately measure subcutaneous adipose tissue (SAT) and visceral adipose tissue (VAT) from images is important for improved assessment and management of patients with various conditions such as obesity, diabetes mellitus, obstructive sleep apnea, cardiovascular disease, kidney disease, and degenerative disease. Although imaging and analysis methods to measure the volume of these tissue components have been developed [1, 2], in clinical practice, an estimate of the amount of fat is obtained from just one transverse abdominal CT slice typically acquired at the level of the L4-L5 vertebrae for various reasons including decreased radiation exposure and cost [3-5]. It is generally assumed that such an estimate reliably depicts the burden of fat in the body. This paper sets out to answer two questions related to this issue which have not been addressed in the literature. How does one ensure that the slices used for correlation calculation from different subjects are at the same anatomic location? At what anatomic location do the volumes of SAT and VAT correlate maximally with the corresponding single-slice area measures? To answer these questions, we propose two approaches for slice localization: linear mapping and non-linear mapping which is a novel learning based strategy for mapping slice locations to a standardized anatomic space so that same anatomic slice locations are identified in different subjects. We then study the volume-to-area correlations and determine where they become maximal. We demonstrate on 50 abdominal CT data sets that this mapping achieves significantly improved consistency of anatomic localization compared to current practice. Our results also indicate that maximum correlations are achieved at different anatomic locations for SAT and VAT which are both different from the L4-L5 junction commonly utilized.

  19. Anatomical calibration for wearable motion capture systems: Video calibrated anatomical system technique.

    PubMed

    Bisi, Maria Cristina; Stagni, Rita; Caroselli, Alessio; Cappello, Angelo

    2015-08-01

    Inertial sensors are becoming widely used for the assessment of human movement in both clinical and research applications, thanks to their usability out of the laboratory. This work aims to propose a method for calibrating anatomical landmark position in the wearable sensor reference frame with an ease to use, portable and low cost device. An off-the-shelf camera, a stick and a pattern, attached to the inertial sensor, compose the device. The proposed technique is referred to as video Calibrated Anatomical System Technique (vCAST). The absolute orientation of a synthetic femur was tracked both using the vCAST together with an inertial sensor and using stereo-photogrammetry as reference. Anatomical landmark calibration showed mean absolute error of 0.6±0.5 mm: these errors are smaller than those affecting the in-vivo identification of anatomical landmarks. The roll, pitch and yaw anatomical frame orientations showed root mean square errors close to the accuracy limit of the wearable sensor used (1°), highlighting the reliability of the proposed technique. In conclusion, the present paper proposes and preliminarily verifies the performance of a method (vCAST) for calibrating anatomical landmark position in the wearable sensor reference frame: the technique is low time consuming, highly portable, easy to implement and usable outside laboratory. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.

  20. Three-Dimensional Display Technologies for Anatomical Education: A Literature Review

    NASA Astrophysics Data System (ADS)

    Hackett, Matthew; Proctor, Michael

    2016-08-01

    Anatomy is a foundational component of biological sciences and medical education and is important for a variety of clinical tasks. To augment current curriculum and improve students' spatial knowledge of anatomy, many educators, anatomists, and researchers use three-dimensional (3D) visualization technologies. This article reviews 3D display technologies and their associated assessments for anatomical education. In the first segment, the review covers the general function of displays employing 3D techniques. The second segment of the review highlights the use and assessment of 3D technology in anatomical education, focusing on factors such as knowledge gains, student perceptions, and cognitive load. The review found 32 articles on the use of 3D displays in anatomical education and another 38 articles on the assessment of 3D displays. The review shows that the majority (74 %) of studies indicate that the use of 3D is beneficial for many tasks in anatomical education, and that student perceptions are positive toward the technology.

  1. Anatomical landmark asymmetry assessment in the lumbar spine and pelvis: a review of reliability.

    PubMed

    Stovall, Bradley Alan; Kumar, Shrawan

    2010-01-01

    The purpose of this article is to review current research investigating the reliability of bony anatomical landmark positional asymmetry assessment in the lumbar spine and pelvis, to determine the agreement on findings between authors, and to explore future directions in the area to address the significant issues. The databases MEDLINE, CINAHL, AMED, MANTIS, Academic Search Complete, and Web of Knowledge were searched. A total of 23 articles were identified and reviewed, 10 of which met the inclusion criteria. For these 10 articles, the average interexaminer reliability for bony anatomical landmark positional asymmetry assessment was slightly above chance for all landmarks except medial malleolus, which had fair reliability. Interexaminer reliability on average was less than intraexaminer reliability (anterior superior iliac spine, k = 0.128/0.414; posterior superior iliac spine, k = 0.092/0.371). All interexaminer reliability averages were below values of clinical significance. From the current literature review, bony anatomical landmark positional asymmetry assessment in the lumbar spine and pelvis has not been demonstrated to be a reliable assessment method. However, there are unexplored factors that, after standardization, may improve reliability and further the understanding of musculoskeletal palpatory examination.

  2. An anatomical study of wormian bones from the eastern part of India: is genetic influence a primary determinant of their morphogenesis?

    PubMed

    Ghosh, Sanjib Kumar; Biswas, Sudipa; Sharma, Suranjali; Chakraborty, Soumya

    2017-06-01

    Over the years a number of investigators have analysed the morphology of wormian bones in different population groups across the world. There have been significant variations between findings reported in these studies, and this has prompted researchers to focus on the influence of genetic factors on the morphology of these bones. In the light of the above observation, we considered it justified to conduct anatomical studies on wormian bones in different population groups; hence, we undertook the present study to look into the morphological details of these bones among a population in the eastern part of India. We observed a total of 120 adult dry human skulls of unknown age and sex, and noted the anatomical details of wormian bones when present. It was observed that wormian bones were present in 45 % of skulls, and that 30 % of skulls had more than one wormian bone. We also found that 2.5 % of the skulls had ten or more wormian bones, which is considered as pathognomonic. Maximum incidence (53.33 %) was observed at the lambdoid suture and minimum incidence at the bregma and metopic suture (0.61 % in each case). We noted a high incidence (21.21 %) of Inca bone/lambdoid ossicle, and bilaterally symmetrical wormian bones were present in 12.5 % study skulls. There were statistically significant (P < 0.05) variations between the findings of the present study and values reported in previous studies conducted in other regions of India and different parts of the world. Our observations favour the view that genetic influence primarily determines the morphology of wormian bones.

  3. ArthroBroström Lateral Ankle Stabilization Technique: An Anatomic Study.

    PubMed

    Acevedo, Jorge I; Ortiz, Cristian; Golano, Pau; Nery, Caio

    2015-10-01

    Arthroscopic ankle lateral ligament repair techniques have recently been developed and biomechanically as well as clinically validated. Although there has been 1 anatomic study relating suture and anchor proximity to anatomic structures, none has evaluated the ArthroBroström procedure. To evaluate the proximity of anatomic structures for the ArthroBroström lateral ankle ligament stabilization technique and to define ideal landmarks and "safe zones" for this repair. Descriptive laboratory study. Ten human cadaveric ankle specimens (5 matched pairs) were screened for the study. All specimens underwent arthroscopic lateral ligament repair according to the previously described ArthroBroström technique with 2 suture anchors in the fibula. Three cadaveric specimens were used to test the protocol, and 7 were dissected to determine the proximity of anatomic structures. Several distances were measured, including those of different anatomic structures to the suture knots, to determine the "safe zones." Measurements were obtained by 2 separate observers, and statistical analysis was performed. None of the specimens revealed entrapment by either of the suture knots of the critical anatomic structures, including the superficial peroneal nerve (SPN), sural nerve, peroneus tertius tendon, peroneus brevis tendon, or peroneus longus tendon. The internervous safe zone between the intermediate branch of the SPN and sural nerve was a mean of 51 mm (range, 39-64 mm). The intertendinous safe zone between the peroneus tertius and peroneus brevis was a mean of 43 mm (range, 37-49 mm). On average, a 20-mm (range, 8-36 mm) safe distance was maintained from the most medial suture to the intermediate branch of the SPN. The amount of inferior extensor retinaculum (IER) grasped by either suture knot varied from 0 to 12 mm, with 86% of repairs including the retinaculum. The results indicate that there is a relatively wide internervous and intertendinous safe zone when performing the Arthro

  4. Anatomical planes: are we teaching accurate surface anatomy?

    PubMed

    Mirjalili, S Ali; McFadden, Sarah L; Buckenham, Tim; Wilson, Ben; Stringer, Mark D

    2012-10-01

    Anatomical planes used in clinical practice and teaching anatomy are largely derived from cadaver studies. Numerous inconsistencies in clinically important surface markings exist between and within anatomical reference texts. The aim of this study was to reassess the accuracy of common anatomical planes in vivo using computed tomographic (CT) imaging. CT scans of the trunk in supine adults at end tidal inspiration were analyzed by dual consensus reporting to determine the anatomy of five anatomical planes: sternal angle, transpyloric, subcostal, supracristal, and the plane of the pubic crest. Patients with kyphosis, scoliosis, or abnormal lordosis, distorting space-occupying lesions, or visceromegaly were excluded. Among 153 thoracic CT scans (mean age 63 years, 53% female), the sternal angle was most common at T4 (females) or T4/5 (males) vertebral level, and the tracheal bifurcation, aortic arch, and pulmonary trunk were most often below this plane. In 108 abdominal CT scans (mean age 60 years, 59% female), the subcostal and supracristal planes were most often at L2 (58%) and L4 (69%), respectively. In 52 thoracoabdominal CT scans (mean age 61 years, 56% female), the transpyloric plane was between lower L1 and upper L2 (75%); in this plane were the superior mesenteric artery (56%), formation of the portal vein (53%), tip of the ninth rib (60%), and the left renal hilum (54%), but the right renal hilum and gallbladder fundus were more often below. The surface anatomy of anatomical planes needs revising in the light of results from living subjects using modern imaging techniques. Copyright © 2012 Wiley Periodicals, Inc.

  5. [Parameters of cardiac muscle repolarization on the electrocardiogram when changing anatomical and electric position of the heart].

    PubMed

    Chaĭkovskiĭ, I A; Baum, O V; Popov, L A; Voloshin, V I; Budnik, N N; Frolov, Iu A; Kovalenko, A S

    2014-01-01

    While discussing the diagnostic value of the single channel electrocardiogram a set of theoretical considerations emerges inevitably, one of the most important among them is the question about dependence of the electrocardiogram parameters from the direction of electrical axis of heart. In other words, changes in what of electrocardiogram parameters are in fact liable to reflect pathological processes in myocardium, and what ones are determined by extracardiac factors, primarily by anatomic characteristics of patients. It is arguable that while analyzing electrocardiogram it is necessary to orient to such physiologically based informative indexes as ST segment displacement. Also, symmetry of the T wave shape is an important parameter which is independent of patients anatomic features. The results obtained are of interest for theoretical and applied aspects of the biophysics of the cardiac electric field.

  6. Anatomical Individualized ACL Reconstruction.

    PubMed

    Rahnemai-Azar, Amir Ata; Sabzevari, Soheil; Irarrázaval, Sebastián; Chao, Tom; Fu, Freddie H

    2016-10-01

    The anterior cruciate ligament (ACL) is composed of two bundles, which work together to provide both antero-posterior and rotatory stability of the knee. Understanding the anatomy and function of the ACL plays a key role in management of patients with ACL injury. Anatomic ACL reconstruction aims to restore the function of the native ACL. Femoral and tibial tunnels should be placed in their anatomical location accounting for both the native ACL insertion site and bony landmarks. One main component of anatomical individualized ACL reconstruction is customizing the treatment according to each patient's individual characteristics, considering preoperative and intraoperative evaluation of the native ACL and knee bony anatomy. Anatomical individualized reconstruction surgery should also aim to restore the size of the native ACL insertion as well. Using this concept, while single bundle ACL reconstruction can restore the function of the ACL in some patients, double bundle reconstruction is indicated in others to achieve optimal outcome.

  7. Anatomical variations of the carpal tunnel structures

    PubMed Central

    Mitchell, Ryan; Chesney, Amy; Seal, Shane; McKnight, Leslie; Thoma, Achilleas

    2009-01-01

    There are many anatomical variations in and around the carpal tunnel that affect the nerves, tendons and arteries in this area. Awareness of these variations is important both during the clinical examination and during carpal tunnel release. The purpose of the present review is to highlight recognized anatomical variations within the carpal tunnel including variation in nerve anatomy, tendon anatomical variants, vascular anatomical variations and muscle anatomical variations. PMID:20808747

  8. Anatomical curve identification

    PubMed Central

    Bowman, Adrian W.; Katina, Stanislav; Smith, Joanna; Brown, Denise

    2015-01-01

    Methods for capturing images in three dimensions are now widely available, with stereo-photogrammetry and laser scanning being two common approaches. In anatomical studies, a number of landmarks are usually identified manually from each of these images and these form the basis of subsequent statistical analysis. However, landmarks express only a very small proportion of the information available from the images. Anatomically defined curves have the advantage of providing a much richer expression of shape. This is explored in the context of identifying the boundary of breasts from an image of the female torso and the boundary of the lips from a facial image. The curves of interest are characterised by ridges or valleys. Key issues in estimation are the ability to navigate across the anatomical surface in three-dimensions, the ability to recognise the relevant boundary and the need to assess the evidence for the presence of the surface feature of interest. The first issue is addressed by the use of principal curves, as an extension of principal components, the second by suitable assessment of curvature and the third by change-point detection. P-spline smoothing is used as an integral part of the methods but adaptations are made to the specific anatomical features of interest. After estimation of the boundary curves, the intermediate surfaces of the anatomical feature of interest can be characterised by surface interpolation. This allows shape variation to be explored using standard methods such as principal components. These tools are applied to a collection of images of women where one breast has been reconstructed after mastectomy and where interest lies in shape differences between the reconstructed and unreconstructed breasts. They are also applied to a collection of lip images where possible differences in shape between males and females are of interest. PMID:26041943

  9. [Establishment of anatomical terminology in Japan].

    PubMed

    Shimada, Kazuyuki

    2008-12-01

    The history of anatomical terminology in Japan began with the publication of Waran Naikei Ihan-teimŏ in 1805 and Chŏtei Kaitai Shinsho in 1826. Although the establishment of Japanese anatomical terminology became necessary during the Meiji era when many western anatomy books imported into Janan were translated, such terminology was not unified during this period and varied among translators. In 1871, Tsukumo Ono's Kaibŏgaku Gosen was published by the Ministry of Education. Although this book is considered to be the first anatomical glossary terms in Japan, its contents were incomplete. Overseas, the German Anatomical Society established a unified anatomical terminology in 1895 called the Basle Nomina Anatomica (B.N.A.). Based on this development, Kaibŏgaku Meishŭ which follows the BNA, by Buntarŏ Suzuki was published in 1905. With the subsequent establishment in 1935 of Jena Nomina Anatomica (J.N.A.), the unification of anatomical terminology was also accelerated in Japan, leading to the further development of terminology.

  10. Validation of hand and foot anatomical feature measurements from smartphone images

    NASA Astrophysics Data System (ADS)

    Amini, Mohammad; Vasefi, Fartash; MacKinnon, Nicholas

    2018-02-01

    A smartphone mobile medical application, previously presented as a tool for individuals with hand arthritis to assess and monitor the progress of their disease, has been modified and expanded to include extraction of anatomical features from the hand (joint/finger width, and angulation) and foot (length, width, big toe angle, and arch height index) from smartphone camera images. Image processing algorithms and automated measurements were validated by performing tests on digital hand models, rigid plastic hand models, and real human hands and feet to determine accuracy and reproducibility compared to conventional measurement tools such as calipers, rulers, and goniometers. The mobile application was able to provide finger joint width measurements with accuracy better than 0.34 (+/-0.25) millimeters. Joint angulation measurement accuracy was better than 0.50 (+/-0.45) degrees. The automatically calculated foot length accuracy was 1.20 (+/-1.27) millimeters and the foot width accuracy was 1.93 (+/-1.92) millimeters. Hallux valgus angle (used in assessing bunions) accuracy was 1.30 (+/-1.29) degrees. Arch height index (AHI) measurements had an accuracy of 0.02 (+/-0.01). Combined with in-app documentation of symptoms, treatment, and lifestyle factors, the anatomical feature measurements can be used by both healthcare professionals and manufacturers. Applications include: diagnosing hand osteoarthritis; providing custom finger splint measurements; providing compression glove measurements for burn and lymphedema patients; determining foot dimensions for custom shoe sizing, insoles, orthotics, or foot splints; and assessing arch height index and bunion treatment effectiveness.

  11. Comparative evaluation between anatomic and non-anatomic lateral ligament reconstruction techniques in the ankle joint: A computational study.

    PubMed

    Purevsuren, Tserenchimed; Batbaatar, Myagmarbayar; Khuyagbaatar, Batbayar; Kim, Kyungsoo; Kim, Yoon Hyuk

    2018-03-12

    Biomechanical studies have indicated that the conventional non-anatomic reconstruction techniques for lateral ankle sprain (LAS) tend to restrict subtalar joint motion compared to intact ankle joints. Excessive restriction in subtalar motion may lead to chronic pain, functional difficulties, and development of osteoarthritis. Therefore, various anatomic surgical techniques to reconstruct both the anterior talofibular and calcaneofibular ligaments have been introduced. In this study, ankle joint stability was evaluated using multibody computational ankle joint model to assess two new anatomic reconstruction and three popular non-anatomic reconstruction techniques. An LAS injury, three popular non-anatomic reconstruction models (Watson-Jones, Evans, and Chrisman-Snook), and two common types of anatomic reconstruction models were developed based on the intact ankle model. The stability of ankle in both talocrural and subtalar joint were evaluated under anterior drawer test (150 N anterior force), inversion test (3 Nm inversion moment), internal rotational test (3 Nm internal rotation moment), and the combined loading test (9 Nm inversion and internal moment as well as 1800 N compressive force). Our overall results show that the two anatomic reconstruction techniques were superior to the non-anatomic reconstruction techniques in stabilizing both talocrural and subtalar joints. Restricted subtalar joint motion, which mainly observed in Watson-Jones and Chrisman-Snook techniques, was not shown in the anatomical reconstructions. Evans technique was beneficial for subtalar joint as it does not restrict subtalar motion, though Evans technique was insufficient for restoring talocrural joint inversion. The anatomical reconstruction techniques best recovered ankle stability.

  12. Renal mass anatomic characteristics and perioperative outcomes of laparoscopic partial nephrectomy: a critical analysis.

    PubMed

    Tsivian, Matvey; Ulusoy, Said; Abern, Michael; Wandel, Ayelet; Sidi, A Ami; Tsivian, Alexander

    2012-10-01

    Anatomic parameters determining renal mass complexity have been used in a number of proposed scoring systems despite lack of a critical analysis of their independent contributions. We sought to assess the independent contribution of anatomic parameters on perioperative outcomes of laparoscopic partial nephrectomy (LPN). Preoperative imaging studies were reviewed for 147 consecutive patients undergoing LPN for a single renal mass. Renal mass anatomy was recorded: Size, growth pattern (endo-/meso-/exophytic), centrality (central/hilar/peripheral), anterior/posterior, lateral/medial, polar location. Multivariable models were used to determine associations of anatomic parameters with warm ischemia time (WIT), operative time (OT), estimated blood loss (EBL), intra- and postoperative complications, as well as renal function. All models were adjusted for the learning curve and relevant confounders. Median (range) tumor size was 3.3 cm (1.5-11 cm); 52% were central and 14% hilar. While 44% were exophytic, 23% and 33% were mesophytic and endophytic, respectively. Anatomic parameters did not uniformly predict perioperative outcomes. WIT was associated with tumor size (P=0.068), centrality (central, P=0.016; hilar, P=0.073), and endophytic growth pattern (P=0.017). OT was only associated with tumor size (P<0.001). No anatomic parameter predicted EBL. Tumor centrality increased the odds of overall and intraoperative complications, without reaching statistical significance. Postoperative renal function was not associated with any of the anatomic parameters considered after adjustment for baseline function and WIT. Learning curve, considered as a confounder, was independently associated with reduced WIT and OT as well as reduced odds of intraoperative complications. This study provides a detailed analysis of the independent impact of renal mass anatomic parameters on perioperative outcomes. Our findings suggest diverse independent contributions of the anatomic parameters to

  13. Determining the Number of Factors in P-Technique Factor Analysis

    ERIC Educational Resources Information Center

    Lo, Lawrence L.; Molenaar, Peter C. M.; Rovine, Michael

    2017-01-01

    Determining the number of factors is a critical first step in exploratory factor analysis. Although various criteria and methods for determining the number of factors have been evaluated in the usual between-subjects R-technique factor analysis, there is still question of how these methods perform in within-subjects P-technique factor analysis. A…

  14. Does EMS Perceived Anatomic Injury Predict Trauma Center Need?

    PubMed Central

    Lerner, E. Brooke; Roberts, Jennifer; Guse, Clare E.; Shah, Manish N.; Swor, Robert; Cushman, Jeremy T.; Blatt, Alan; Jurkovich, Gregory J.; Brasel, Karen

    2013-01-01

    Objective Our objective was to determine the predictive value of the anatomic step of the 2011 Field Triage Decision Scheme for identifying trauma center need. Methods EMS providers caring for injured adults transported to regional trauma centers in 3 midsized communities were interviewed over two years. Patients were included, regardless of injury severity, if they were at least 18 years old and were transported by EMS with a mechanism of injury that was an assault, motor vehicle or motorcycle crash, fall, or pedestrian or bicyclist struck. The interview was conducted upon ED arrival and collected physiologic condition and anatomic injury data. Patients who met the physiologic criteria were excluded. Trauma center need was defined as non-orthopedic surgery within 24 hours, intensive care unit admission, or death prior to hospital discharge. Data were analyzed by calculating descriptive statistics including positive likelihood ratios (+LR) with 95% confidence intervals. Results 11,892 interviews were conducted. One was excluded because of missing outcome data and 1,274 were excluded because they met the physiologic step. EMS providers identified 1,167 cases that met the anatomic criteria, of which 307 (26%) needed the resources of a trauma center (38% sensitivity, 91% specificity, +LR 4.4; CI: 3.9 - 4.9). Criteria with a +LR ≥5 were flail chest (9.0; CI: 4.1 - 19.4), paralysis (6.8; CI: 4.2 - 11.2), two or more long bone fractures (6.3; CI: 4.5 - 8.9), and amputation (6.1; CI: 1.5 - 24.4). Criteria with a +LR >2 and <5 were penetrating injury (4.8; CI: 4.2 - 5.6), and skull fracture (4.8; CI: 3.0 - 7.7). Only pelvic fracture (1.9; CI: 1.3 - 2.9) had a +LR less than 2. Conclusions The anatomic step of the Field Triage Guidelines as determined by EMS providers is a reasonable tool for determining trauma center need. Use of EMS perceived pelvic fracture as an indicator for trauma center need should be re-evaluated. PMID:23627418

  15. Segmentation of medical images using explicit anatomical knowledge

    NASA Astrophysics Data System (ADS)

    Wilson, Laurie S.; Brown, Stephen; Brown, Matthew S.; Young, Jeanne; Li, Rongxin; Luo, Suhuai; Brandt, Lee

    1999-07-01

    Knowledge-based image segmentation is defined in terms of the separation of image analysis procedures and representation of knowledge. Such architecture is particularly suitable for medical image segmentation, because of the large amount of structured domain knowledge. A general methodology for the application of knowledge-based methods to medical image segmentation is described. This includes frames for knowledge representation, fuzzy logic for anatomical variations, and a strategy for determining the order of segmentation from the modal specification. This method has been applied to three separate problems, 3D thoracic CT, chest X-rays and CT angiography. The application of the same methodology to such a range of applications suggests a major role in medical imaging for segmentation methods incorporating representation of anatomical knowledge.

  16. A Procedure for Calculating the Vertical Space Height of the Sacrum When Determining Skeletal Height for Use in the Anatomical Method of Adult Stature Estimation.

    PubMed

    Hayashi, Atsuko; Emanovsky, Paul D; Pietrusewsky, Michael; Holland, Thomas D

    2016-03-01

    Estimating stature from skeletonized remains is one of the essential parameters in the development of a biological profile. A new procedure for determining skeletal height (SKH) incorporating the vertical space height (VSH) from the anterior margin of the sacral promontory to the superior margins of the acetabulae for use in the anatomical method of stature estimation is introduced. Regression equations for stature estimation were generated from measurements of 38 American males of European ancestry from the William M. Bass Donated Skeletal Collection. The modification to the procedure results in a SKH that is highly correlated with stature (r = 0.925-0.948). Stature estimates have low standard errors of the estimate ranging from 21.79 to 25.95 mm, biases from to 0.50 to 0.94 mm, and accuracy rates from 17.71 mm to 19.45 mm. The procedure for determining the VSH, which replaces "S1 height" in traditional anatomical method models, is a key improvement to the method. © 2016 American Academy of Forensic Sciences.

  17. Anatomic Optical Coherence Tomography of Upper Airways

    NASA Astrophysics Data System (ADS)

    Chin Loy, Anthony; Jing, Joseph; Zhang, Jun; Wang, Yong; Elghobashi, Said; Chen, Zhongping; Wong, Brian J. F.

    The upper airway is a complex and intricate system responsible for respiration, phonation, and deglutition. Obstruction of the upper airways afflicts an estimated 12-18 million Americans. Pharyngeal size and shape are important factors in the pathogenesis of airway obstructions. In addition, nocturnal loss in pharyngeal muscular tone combined with high pharyngeal resistance can lead to collapse of the airway and periodic partial or complete upper airway obstruction. Anatomical optical coherence tomography (OCT) has the potential to provide high-speed three-dimensional tomographic images of the airway lumen without the use of ionizing radiation. In this chapter we describe the methods behind endoscopic OCT imaging and processing to generate full three dimensional anatomical models of the human airway which can be used in conjunction with numerical simulation methods to assess areas of airway obstruction. Combining this structural information with flow dynamic simulations, we can better estimate the site and causes of airway obstruction and better select and design surgery for patients with obstructive sleep apnea.

  18. Motivation and Organizational Principles for Anatomical Knowledge Representation

    PubMed Central

    Rosse, Cornelius; Mejino, José L.; Modayur, Bharath R.; Jakobovits, Rex; Hinshaw, Kevin P.; Brinkley, James F.

    1998-01-01

    Abstract Objective: Conceptualization of the physical objects and spaces that constitute the human body at the macroscopic level of organization, specified as a machine-parseable ontology that, in its human-readable form, is comprehensible to both expert and novice users of anatomical information. Design: Conceived as an anatomical enhancement of the UMLS Semantic Network and Metathesaurus, the anatomical ontology was formulated by specifying defining attributes and differentia for classes and subclasses of physical anatomical entities based on their partitive and spatial relationships. The validity of the classification was assessed by instantiating the ontology for the thorax. Several transitive relationships were used for symbolically modeling aspects of the physical organization of the thorax. Results: By declaring Organ as the macroscopic organizational unit of the body, and defining the entities that constitute organs and higher level entities constituted by organs, all anatomical entities could be assigned to one of three top level classes (Anatomical structure, Anatomical spatial entity and Body substance). The ontology accommodates both the systemic and regional (topographical) views of anatomy, as well as diverse clinical naming conventions of anatomical entities. Conclusions: The ontology formulated for the thorax is extendible to microscopic and cellular levels, as well as to other body parts, in that its classes subsume essentially all anatomical entities that constitute the body. Explicit definitions of these entities and their relationships provide the first requirement for standards in anatomical concept representation. Conceived from an anatomical viewpoint, the ontology can be generalized and mapped to other biomedical domains and problem solving tasks that require anatomical knowledge. PMID:9452983

  19. [The anatomic tradition in Venice].

    PubMed

    Capitanio, G; Stracca Pansa, V

    2000-04-01

    Venice had a long tradition and great reputation in the study of anatomical science dating back to the 1300's. The "Serenissima" Republic favoured the study and practice of anatomy as part of medical professional formation. Before the construction of the anatomical theater of San Giacomo dell'Orio, which took place in 1671, anatomical dissections were performed in churches, convents, hospitals and private homes. Even though Venice was not a University seat, it boosted numerous Venetian anatomists, among whom Benedetti, Massa, Santorini, and the medical activity of illustrious professors at the nearby University of Padua such as Vesalio, Falloppio, Spigelio, Vislingio and Morgagni.

  20. TOPICAL REVIEW: Anatomical imaging for radiotherapy

    NASA Astrophysics Data System (ADS)

    Evans, Philip M.

    2008-06-01

    scans is taken on different days. Both allow planning to account for variability intrinsic to the patient. Treatment verification has been carried out using a variety of technologies including: MV portal imaging, kV portal/fluoroscopy, MVCT, conebeam kVCT, ultrasound and optical surface imaging. The various methods have their pros and cons. The four x-ray methods involve an extra radiation dose to normal tissue. The portal methods may not generally be used to visualize soft tissue, consequently they are often used in conjunction with implanted fiducial markers. The two CT-based methods allow measurement of inter-fraction variation only. Ultrasound allows soft-tissue measurement with zero dose but requires skilled interpretation, and there is evidence of systematic differences between ultrasound and other data sources, perhaps due to the effects of the probe pressure. Optical imaging also involves zero dose but requires good correlation between the target and the external measurement and thus is often used in conjunction with an x-ray method. The use of anatomical imaging in radiotherapy allows treatment uncertainties to be determined. These include errors between the mean position at treatment and that at planning (the systematic error) and the day-to-day variation in treatment set-up (the random error). Positional variations may also be categorized in terms of inter- and intra-fraction errors. Various empirical treatment margin formulae and intervention approaches exist to determine the optimum strategies for treatment in the presence of these known errors. Other methods exist to try to minimize error margins drastically including the currently available breath-hold techniques and the tracking methods which are largely in development. This paper will review anatomical imaging techniques in radiotherapy and how they are used to boost the therapeutic benefit of the treatment.

  1. Anatomical background noise power spectrum in differential phase contrast breast images

    NASA Astrophysics Data System (ADS)

    Garrett, John; Ge, Yongshuai; Li, Ke; Chen, Guang-Hong

    2015-03-01

    In x-ray breast imaging, the anatomical noise background of the breast has a significant impact on the detection of lesions and other features of interest. This anatomical noise is typically characterized by a parameter, β, which describes a power law dependence of anatomical noise on spatial frequency (the shape of the anatomical noise power spectrum). Large values of β have been shown to reduce human detection performance, and in conventional mammography typical values of β are around 3.2. Recently, x-ray differential phase contrast (DPC) and the associated dark field imaging methods have received considerable attention as possible supplements to absorption imaging for breast cancer diagnosis. However, the impact of these additional contrast mechanisms on lesion detection is not yet well understood. In order to better understand the utility of these new methods, we measured the β indices for absorption, DPC, and dark field images in 15 cadaver breast specimens using a benchtop DPC imaging system. We found that the measured β value for absorption was consistent with the literature for mammographic acquisitions (β = 3.61±0.49), but that both DPC and dark field images had much lower values of β (β = 2.54±0.75 for DPC and β = 1.44±0.49 for dark field). In addition, visual inspection showed greatly reduced anatomical background in both DPC and dark field images. These promising results suggest that DPC and dark field imaging may help provide improved lesion detection in breast imaging, particularly for those patients with dense breasts, in whom anatomical noise is a major limiting factor in identifying malignancies.

  2. Intraoperative Comparison of Anatomical versus Round Implants in Breast Augmentation: A Randomized Controlled Trial.

    PubMed

    Hidalgo, David A; Weinstein, Andrew L

    2017-03-01

    The purpose of this randomized controlled trial was to determine whether anatomical implants are aesthetically superior to round implants in breast augmentation. Seventy-five patients undergoing primary breast augmentation had a round silicone implant of optimal volume, projection, and diameter placed in one breast and an anatomical silicone device of similar volume and optimal shape placed in the other. After intraoperative photographs were taken, the anatomical device was replaced by a round implant to complete the procedure. A survey designed to measure breast aesthetics was administered to 10 plastic surgeon and 10 lay reviewers for blind evaluation of the 75 cases. No observable difference in breast aesthetics between anatomical and round implants was reported by plastic surgeons in 43.6 percent or by lay individuals in 29.2 percent of cases. When a difference was perceived, neither plastic surgeons nor lay individuals preferred the anatomical side more often than the round side. Plastic surgeons judged the anatomical side superior in 51.1 percent of cases and the round side superior in 48.9 percent of cases (p = 0.496). Lay individuals judged the anatomical side superior in 46.7 percent of cases and the round side superior in 53.3 percent (p = 0.140). Plastic surgeons identified implant shape correctly in only 26.5 percent of cases. This study provides high-level evidence supporting no aesthetic superiority of anatomical over round implants. Given that anatomical implants have important and unique disadvantages, a lack of proven aesthetic superiority argues against their continued use in breast augmentation. Therapeutic, I.

  3. Serological inflammatory factors as biomarkers for anatomic response in diabetic macular edema treated with anti-VEGF.

    PubMed

    Brito, Pedro; Costa, Jorge; Gomes, Nuno; Costa, Sandra; Correia-Pinto, Jorge; Silva, Rufino

    2018-05-11

    To study the relationship between systemic pro-inflammatory factors and macular structural response to intravitreal bevacizumab for diabetic macular edema (DME). Prospective study including 30 cases with DME, treated with bevacizumab and a minimum follow-up of 6 months. All cases underwent baseline laboratory testing for cardiovascular risk (high sensitivity C-reactive protein (hsCRP), homocystein), dyslipidemia, renal dysfunction and glucose control. Serum levels of VEGF, soluble ICAM-1, MCP-1 and TNF-α were assessed by enzyme-linked immunosorbent assay kits. Significant associations between systemic factors and quantitative and qualitative spectral-domain optical coherence macular features were analyzed. A mean of 4.82 ± 0.56 intravitreal injections was performed, resulting in significant improvement of central foveal thickness (CFT) (p < 0.001). A significant association with third month CFT decrease <10% was found for hsCRP (3.33 ± 2.01 vs 1.39 ± 1.15 mg/l, p = 0.007) and ICAM1 (975.54 ± 265.49 vs 727.07 ± 336.09 pg/ml, p = 0.012). ROC curve analysis indicated hsCRP and ICAM1 as significant biomarkers for 3rd month reduced anatomic response (area under the curve (AUC) = 0.807, p = 0.009 for hsCRP; AUC = 0.788, p = 0.014 for ICAM1). ROC curve analysis revealed hsCRP as a significant biomarker for 6th month CFT decrease <10% (AUC = 0.903, p < 0.001, cutoff value = 1.81 mg/l). A significant association with 6th month CFT decrease ≥25% was found for serum MCP1 (244.69 ± 49.34 pg/ml vs 319.24 ± 94.88 pg/ml, p = 0.017) and serum VEGF (90.84 ± 37.33 vs 58.28 ± 25.19 pg/ml, p = 0.027). The combined model of serum VEGF and LDL-cholesterol was found to be predictive of 6th month hard exudate severity (p = 0.001, r2 = 0.463). Increased levels of hsCRP and ICAM1 were found to be significant biomarkers for early reduced anatomic response to anti-VEGF treatment

  4. Historical evolution of anatomical terminology from ancient to modern.

    PubMed

    Sakai, Tatsuo

    2007-06-01

    The historical development of anatomical terminology from the ancient to the modern can be divided into five stages. The initial stage is represented by the oldest extant anatomical treatises by Galen of Pergamon in the Roman Empire. The anatomical descriptions by Galen utilized only a limited number of anatomical terms, which were essentially colloquial words in the Greek of this period. In the second stage, Vesalius in the early 16th century described the anatomical structures in his Fabrica with the help of detailed magnificent illustrations. He coined substantially no anatomical terms, but devised a system that distinguished anatomical structures with ordinal numbers. The third stage of development in the late 16th century was marked by innovation of a large number of specific anatomical terms especially for the muscles, vessels and nerves. The main figures at this stage were Sylvius in Paris and Bauhin in Basel. In the fourth stage between Bauhin and the international anatomical terminology, many anatomical textbooks were written mainly in Latin in the 17th century, and in modern languages in the 18th and 19th centuries. Anatomical terms for the same structure were differently expressed by different authors. The last stage began at the end of the 19th century, when the first international anatomical terminology in Latin was published as Nomina anatomica. The anatomical terminology was revised repeatedly until the current Terminologia anatomica both in Latin and English.

  5. Re-entry using anatomically determined isthmuses: a curable ventricular tachycardia in repaired congenital heart disease.

    PubMed

    Kapel, Gijsbert F L; Reichlin, Tobias; Wijnmaalen, Adrianus P; Piers, Sebastiaan R D; Holman, Eduard R; Tedrow, Usha B; Schalij, Martin J; Stevenson, William G; Zeppenfeld, Katja

    2015-02-01

    Ventricular tachycardia (VT) is an important cause of late morbidity and mortality in repaired congenital heart disease. The substrate often includes anatomic isthmuses that can be transected by radiofrequency catheter ablation similar to isthmus block for atrial flutter. This study evaluates the long-term efficacy of isthmus block for treatment of re-entry VT in adults with repaired congenital heart disease. Thirty-four patients (49±13 years; 74% male) with repaired congenital heart disease who underwent radiofrequency catheter ablation of VT in 2 centers were included. Twenty-two (65%) had a preserved left and right ventricular function. Patients were inducible for 1 (interquartile range, 1-2) VT, median cycle length: 295 ms (interquartile range, 242-346). Ablation aimed to transect anatomic isthmuses containing VT re-entry circuit isthmuses. Procedural success was defined as noninducibility of any VT and transection of the anatomic isthmus and was achieved in 25 (74%) patients. During long-term follow-up (46±29 months), all patients with procedural success (18/25 with internal cardiac defibrillators) were free of VT recurrence but 7 of 18 experienced internal cardiac defibrillator-related complications. One patient with procedural success and depressed cardiac function received an internal cardiac defibrillator shock for ventricular fibrillation. None of the 18 patients (12/18 with internal cardiac defibrillators) with complete success and preserved cardiac function experienced any ventricular arrhythmia. In contrast, VT recurred in 4 of 9 patients without procedural success. Four patients died from nonarrhythmic causes. In patients with repaired congenital heart disease with preserved ventricular function and isthmus-dependent re-entry, VT isthmus ablation can be curative. © 2014 American Heart Association, Inc.

  6. A time dependent anatomically detailed model of cardiac conduction

    NASA Technical Reports Server (NTRS)

    Saxberg, B. E.; Grumbach, M. P.; Cohen, R. J.

    1985-01-01

    In order to understand the determinants of transitions in cardiac electrical activity from normal patterns to dysrhythmias such as ventricular fibrillation, we are constructing an anatomically and physiologically detailed finite element simulation of myocardial electrical propagation. A healthy human heart embedded in paraffin was sectioned to provide a detailed anatomical substrate for model calculations. The simulation of propagation includes anisotropy in conduction velocity due to fiber orientation as well as gradients in conduction velocities, absolute and relative refractory periods, action potential duration and electrotonic influence of nearest neighbors. The model also includes changes in the behaviour of myocardial tissue as a function of the past local activity. With this model, we can examine the significance of fiber orientation and time dependence of local propagation parameters on dysrhythmogenesis.

  7. [BIRTH AND DEVELOPMENT OF THE ANATOMICAL MUSEUMS OF MODENA BETWEEN XVIII AND XIX CENTURY. THE OBSTETRIC MUSEUM, THE ANATOMICAL MUSEUM, THE ETHNOGRAPHIC ANTHROPOLOGIC MUSEUM].

    PubMed

    Corradini, Elena

    2015-01-01

    The interest for the study of Anatomy in Modena was particularly developed since the second half of eighteenth century, when the Duke Francesco III of Este promoted the reformation of the University and Antonio Scarpa was called from Padua to teach Anatomy. Scarpa promoted the building of the Anatomical Theatre, near the Grande Spedale, that was inaugurated in 1776. On the same year, the School of Obstetrics opened and determined the constitution of a first Cabinet or Obstetric Museum in a room next to the Theatre. After the Restoration, between 1817 and 1818, the Archduke Francesco IV of Austria Este promoted the realization of an Anatomical Museum: a big organized room in a new floor built on the Theatre. Two more rooms were added in, 1839 and a fourth one in 1853, under the direction of Paolo Gaddi. Furthermore Gaddi's interest for ethnographic studies determined the opening of the Ethnographic Anthropological Museum in 1866.

  8. The female knee: anatomic variations.

    PubMed

    Conley, Sheryl; Rosenberg, Aaron; Crowninshield, Roy

    2007-01-01

    Traditional knee implants have been designed "down the middle,"based on the combined average size and shape of male and female knee anatomy.Sex-based research in the field of orthopaedics has led to new understanding of the anatomic differences between the sexes and the associated implications for women undergoing total knee arthroplasty. Through the use of a comprehensive bone morphology atlas that utilizes novel three-dimensional computed tomography analysis technology, significant anatomic differences have been documented in the shape and size of female knees compared with male knees. This research identifies three notable anatomic differences in the female population: a less prominent anterior condyle, an increased Q angle, and a reduced medial-lateral:anterior-posterior aspect ratio.

  9. Anatomical popliteal artery entrapment syndrome.

    PubMed

    Kwon, Yong Jae; Kwon, Tae-Won; Gwon, Jun Gyo; Cho, Yong-Pil; Hwang, Seung-Jun; Go, Ki-Young

    2018-05-01

    The aim of this study was to analyze anatomical popliteal artery entrapment syndrome (PAES) and to individualize the treatment of this condition according to the anatomical status of the artery and the adjacent structure. A total of 35 anatomical PAES legs in 23 consecutive patients treated within the Asan Medical Center, Seoul, Korea between 1995 and 2011 were analyzed retrospectively. Anatomical PAES was diagnosed by MRI and/or CT scans of the knee joint, and CT or conventional transfemoral arteriography of the lower extremities. We noted a type II gastrocnemius medial head (GNM) anomaly, a type III GNM anomaly, or an aberrant plantaris muscle in 51.4%, 20%, and 28.6% of PAES legs, respectively. In assessments of the arterial lesions, popliteal or tibial artery occlusion was noted in 19 of 26 symptomatic PAES legs. For cases without popliteal artery lesions, myotomy of the anatomically deranged muscle was performed in 5 of 7 symptomatic and 4 of 9 asymptomatic PAES legs. For occluded popliteal arteries, we performed ten direct repairs of the pathological popliteal artery and 4 femoro-below the knee popliteal bypass surgeries. As a result of the arterial Surgery, 9 direct procedures with myotomy yielded a patent artery, while 3 graft failures were noted in the bypass group. The median follow-up period was 84 months (range, 12-206 months). We recommend that treatment of PAES should be individualized based on pathology, symptoms, and various imaging studies.

  10. Understanding the Anatomic Basis for Obstructive Sleep Apnea Syndrome in Adolescents

    PubMed Central

    Kim, Christopher; Bagchi, Sheila; Keenan, Brendan T.; Comyn, François-Louis; Wang, Stephen; Tapia, Ignacio E.; Huang, Shirley; Traylor, Joel; Torigian, Drew A.; Bradford, Ruth M.; Marcus, Carole L.

    2015-01-01

    Rationale: Structural risk factors for obstructive sleep apnea syndrome (OSAS) in adolescents have not been well characterized. Because many adolescents with OSAS are obese, we hypothesized that the anatomic OSAS risk factors would be more similar to those in adults than those in children. Objectives: To investigate the anatomic risk factors in adolescents with OSAS compared with obese and lean control subjects using magnetic resonance imaging (MRI). Methods: Three groups of adolescents (age range: 12–16 yr) underwent MRI: obese individuals with OSAS (n = 49), obese control subjects (n = 38), and lean control subjects (n = 50). Measurements and Main Results: We studied 137 subjects and found that (1) obese adolescents with OSAS had increased adenotonsillar tissue compared with obese and lean control subjects; (2) obese OSAS adolescents had a smaller nasopharyngeal airway than control subjects; (3) the size of other upper airway soft tissue structures (volume of the tongue, parapharyngeal fat pads, lateral walls, and soft palate) was similar between subjects with OSAS and obese control subjects; (4) although there were no major craniofacial abnormalities in most of the adolescents with OSAS, the ratio of soft tissue to craniofacial space surrounding the airway was increased; and (5) there were sex differences in the pattern of lymphoid proliferation. Conclusions: Increased size of the pharyngeal lymphoid tissue, rather than enlargement of the upper airway soft tissue structures, is the primary anatomic risk factor for OSAS in obese adolescents. These results are important for clinical decision making and suggest that adenotonsillectomy should be considered as the initial treatment for OSAS in obese adolescents, a group that has poor continuous positive airway pressure adherence and difficulty in achieving weight loss. PMID:25835282

  11. Development of a patient-specific anatomical foot model from structured light scan data.

    PubMed

    Lochner, Samuel J; Huissoon, Jan P; Bedi, Sanjeev S

    2014-01-01

    The use of anatomically accurate finite element (FE) models of the human foot in research studies has increased rapidly in recent years. Uses for FE foot models include advancing knowledge of orthotic design, shoe design, ankle-foot orthoses, pathomechanics, locomotion, plantar pressure, tissue mechanics, plantar fasciitis, joint stress and surgical interventions. Similar applications but for clinical use on a per-patient basis would also be on the rise if it were not for the high costs associated with developing patient-specific anatomical foot models. High costs arise primarily from the expense and challenges of acquiring anatomical data via magnetic resonance imaging (MRI) or computed tomography (CT) and reconstructing the three-dimensional models. The proposed solution morphs detailed anatomy from skin surface geometry and anatomical landmarks of a generic foot model (developed from CT or MRI) to surface geometry and anatomical landmarks acquired from an inexpensive structured light scan of a foot. The method yields a patient-specific anatomical foot model at a fraction of the cost of standard methods. Average error for bone surfaces was 2.53 mm for the six experiments completed. Highest accuracy occurred in the mid-foot and lowest in the forefoot due to the small, irregular bones of the toes. The method must be validated in the intended application to determine if the resulting errors are acceptable.

  12. Professionals' Standards of "Normal" Behavior with Anatomical Dolls and Factors That Influence These Standards.

    ERIC Educational Resources Information Center

    Kendall-Tackett, Kathleen A.

    A total of 201 professionals who work with victims of child sexual abuse were asked to rate the extent to which various behaviors with anatomically correct dolls would be normal for nonabused children between 2 and 5.9 years of age. Subjects were either law enforcement or mental health professionals. Behaviors ranged from such ambiguous behaviors…

  13. [Graphic reconstruction of anatomic surfaces].

    PubMed

    Ciobanu, O

    2004-01-01

    The paper deals with the graphic reconstruction of anatomic surfaces in a virtual 3D setting. Scanning technologies and soft provides a greater flexibility in the digitization of surfaces and a higher resolution and accuracy. An alternative cheap method for the reconstruction of 3D anatomic surfaces is presented in connection with some studies and international projects developed by Medical Design research team.

  14. In vivo estimation of normal amygdala volume from structural MRI scans with anatomical-based segmentation.

    PubMed

    Siozopoulos, Achilleas; Thomaidis, Vasilios; Prassopoulos, Panos; Fiska, Aliki

    2018-02-01

    Literature includes a number of studies using structural MRI (sMRI) to determine the volume of the amygdala, which is modified in various pathologic conditions. The reported values vary widely mainly because of different anatomical approaches to the complex. This study aims at estimating of the normal amygdala volume from sMRI scans using a recent anatomical definition described in a study based on post-mortem material. The amygdala volume has been calculated in 106 healthy subjects, using sMRI and anatomical-based segmentation. The resulting volumes have been analyzed for differences related to hemisphere, sex, and age. The mean amygdalar volume was estimated at 1.42 cm 3 . The mean right amygdala volume has been found larger than the left, but the difference for the raw values was within the limits of the method error. No intersexual differences or age-related alterations have been observed. The study provides a method for determining the boundaries of the amygdala in sMRI scans based on recent anatomical considerations and an estimation of the mean normal amygdala volume from a quite large number of scans for future use in comparative studies.

  15. Validation and detection of vessel landmarks by using anatomical knowledge

    NASA Astrophysics Data System (ADS)

    Beck, Thomas; Bernhardt, Dominik; Biermann, Christina; Dillmann, Rüdiger

    2010-03-01

    The detection of anatomical landmarks is an important prerequisite to analyze medical images fully automatically. Several machine learning approaches have been proposed to parse 3D CT datasets and to determine the location of landmarks with associated uncertainty. However, it is a challenging task to incorporate high-level anatomical knowledge to improve these classification results. We propose a new approach to validate candidates for vessel bifurcation landmarks which is also applied to systematically search missed and to validate ambiguous landmarks. A knowledge base is trained providing human-readable geometric information of the vascular system, mainly vessel lengths, radii and curvature information, for validation of landmarks and to guide the search process. To analyze the bifurcation area surrounding a vessel landmark of interest, a new approach is proposed which is based on Fast Marching and incorporates anatomical information from the knowledge base. Using the proposed algorithms, an anatomical knowledge base has been generated based on 90 manually annotated CT images containing different parts of the body. To evaluate the landmark validation a set of 50 carotid datasets has been tested in combination with a state of the art landmark detector with excellent results. Beside the carotid bifurcation the algorithm is designed to handle a wide range of vascular landmarks, e.g. celiac, superior mesenteric, renal, aortic, iliac and femoral bifurcation.

  16. [The alteration of Japanese anatomical terminology in the early Showa period and the Japanese language reform campaign].

    PubMed

    Sawai, Tadashi; Sakai, Tatsuo

    2010-03-01

    In the second decade of the Showa period, great changes were made in the Japanese anatomical terms. It has been proposed that the presentation of JNA (Jenaer nomina anatomica) was one of the factors leading to the change. The Japanese language reform campaign, however, played an important role. The party kokugoaigo doumei and its successor kokugo kyokai required concise and unified technical terms. The anatomical nomenclature committee of the Japanese Association of Anatomists worked to satisfy this requirement. The committee consulted with nomenclature committees of other medical associations and took account of their opinions. The anatomical nomenclature committee abandoned the literal translation from Latin to Japanese and shaped a succinct Japanese terminology. Modern Japanese anatomical terms are based on this terminology.

  17. Anatomical frame identification and reconstruction for repeatable lower limb joint kinematics estimates.

    PubMed

    Donati, Marco; Camomilla, Valentina; Vannozzi, Giuseppe; Cappozzo, Aurelio

    2008-07-19

    The quantitative description of joint mechanics during movement requires the reconstruction of the position and orientation of selected anatomical axes with respect to a laboratory reference frame. These anatomical axes are identified through an ad hoc anatomical calibration procedure and their position and orientation are reconstructed relative to bone-embedded frames normally derived from photogrammetric marker positions and used to describe movement. The repeatability of anatomical calibration, both within and between subjects, is crucial for kinematic and kinetic end results. This paper illustrates an anatomical calibration approach, which does not require anatomical landmark manual palpation, described in the literature to be prone to great indeterminacy. This approach allows for the estimate of subject-specific bone morphology and automatic anatomical frame identification. The experimental procedure consists of digitization through photogrammetry of superficial points selected over the areas of the bone covered with a thin layer of soft tissue. Information concerning the location of internal anatomical landmarks, such as a joint center obtained using a functional approach, may also be added. The data thus acquired are matched with the digital model of a deformable template bone. Consequently, the repeatability of pelvis, knee and hip joint angles is determined. Five volunteers, each of whom performed five walking trials, and six operators, with no specific knowledge of anatomy, participated in the study. Descriptive statistics analysis was performed during upright posture, showing a limited dispersion of all angles (less than 3 deg) except for hip and knee internal-external rotation (6 deg and 9 deg, respectively). During level walking, the ratio of inter-operator and inter-trial error and an absolute subject-specific repeatability were assessed. For pelvic and hip angles, and knee flexion-extension the inter-operator error was equal to the inter-trial error

  18. Anatomical noise in contrast-enhanced digital mammography. Part II. Dual-energy imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hill, Melissa L.; Yaffe, Martin J.; Mainprize, James G.

    2013-08-15

    Purpose: Dual-energy (DE) contrast-enhanced digital mammography (CEDM) uses an iodinated contrast agent in combination with digital mammography (DM) to evaluate lesions on the basis of tumor angiogenesis. In DE imaging, low-energy (LE) and high-energy (HE) images are acquired after contrast administration and their logarithms are subtracted to cancel the appearance of normal breast tissue. Often there is incomplete signal cancellation in the subtracted images, creating a background “clutter” that can impair lesion detection. This is the second component of a two-part report on anatomical noise in CEDM. In Part I the authors characterized the anatomical noise for single-energy (SE) temporalmore » subtraction CEDM by a power law, with model parameters α and β. In this work the authors quantify the anatomical noise in DE CEDM clinical images and compare this with the noise in SE CEDM. The influence on the anatomical noise of the presence of iodine in the breast, the timing of imaging postcontrast administration, and the x-ray energy used for acquisition are each evaluated.Methods: The power law parameters, α and β, were measured from unprocessed LE and HE images and from DE subtracted images to quantify the anatomical noise. A total of 98 DE CEDM cases acquired in a previous clinical pilot study were assessed. Conventional DM images from 75 of the women were evaluated for comparison with DE CEDM. The influence of the imaging technique on anatomical noise was determined from an analysis of differences between the power law parameters as measured in DM, LE, HE, and DE subtracted images for each subject.Results: In DE CEDM, weighted image subtraction lowers β to about 1.1 from 3.2 and 3.1 in LE and HE unprocessed images, respectively. The presence of iodine has a small but significant effect in LE images, reducing β by about 0.07 compared to DM, with α unchanged. Increasing the x-ray energy, from that typical in DM to a HE beam, significantly decreases α by

  19. Multiple variations of the tendons of the anatomical snuffbox.

    PubMed

    Thwin, San San; Fazlin, Fazlin; Than, Myo

    2014-01-01

    Multiple tendons of the abductor pollicis longus (APL) in the anatomical snuffbox of the wrist can lead to the development of de Quervain's syndrome, which is caused by stenosing tenosynovitis. A cadaveric study was performed to establish the variations present in the tendons of the anatomical snuffbox in a Malaysian population, in the hope that this knowledge would aid clinical investigation and surgical treatment of de Quervain's tenosynovitis. Routine dissection of ten upper limbs was performed to determine the variations in the tendons of the anatomical snuffbox of the wrist. In all the dissected upper limbs, the APL tendon of the first extensor compartment was found to have several (3-14) tendon slips. The insertion of the APL tendon slips in all upper limbs were at the base of the first metacarpal bone, trapezium and fascia of the opponens pollicis muscle; however, in seven specimens, they were also found to be attached to the fleshy belly of the abductor pollicis brevis muscle. In two specimens, double tendons of the extensor pollicis longus located in the third extensor compartment were inserted into the capsule of the proximal interphalangeal joints before being joined to the extensor expansion. In two other specimens, the first extensor compartment had two osseofibrous tunnels divided by a septum that separated the APL tendon from the extensor pollicis brevis tendon. Multiple variations were found in the anatomical snuffbox region of the dissected upper limbs. Knowledge of these variations would be useful in interventional radiology and orthopaedic surgery.

  20. Multiple variations of the tendons of the anatomical snuffbox

    PubMed Central

    Thwin, San San; Zaini, Fazlin; Than, Myo

    2014-01-01

    INTRODUCTION Multiple tendons of the abductor pollicis longus (APL) in the anatomical snuffbox of the wrist can lead to the development of de Quervain's syndrome, which is caused by stenosing tenosynovitis. A cadaveric study was performed to establish the variations present in the tendons of the anatomical snuffbox in a Malaysian population, in the hope that this knowledge would aid clinical investigation and surgical treatment of de Quervain's tenosynovitis. METHODS Routine dissection of ten upper limbs was performed to determine the variations in the tendons of the anatomical snuffbox of the wrist. RESULTS In all the dissected upper limbs, the APL tendon of the first extensor compartment was found to have several (3–14) tendon slips. The insertion of the APL tendon slips in all upper limbs were at the base of the first metacarpal bone, trapezium and fascia of the opponens pollicis muscle; however, in seven specimens, they were also found to be attached to the fleshy belly of the abductor pollicis brevis muscle. In two specimens, double tendons of the extensor pollicis longus located in the third extensor compartment were inserted into the capsule of the proximal interphalangeal joints before being joined to the extensor expansion. In two other specimens, the first extensor compartment had two osseofibrous tunnels divided by a septum that separated the APL tendon from the extensor pollicis brevis tendon. CONCLUSION Multiple variations were found in the anatomical snuffbox region of the dissected upper limbs. Knowledge of these variations would be useful in interventional radiology and orthopaedic surgery. PMID:24452976

  1. Introducing 3-Dimensional Printing of a Human Anatomic Pathology Specimen: Potential Benefits for Undergraduate and Postgraduate Education and Anatomic Pathology Practice.

    PubMed

    Mahmoud, Amr; Bennett, Michael

    2015-08-01

    Three-dimensional (3D) printing, a rapidly advancing technology, is widely applied in fields such as mechanical engineering and architecture. Three-dimensional printing has been introduced recently into medical practice in areas such as reconstructive surgery, as well as in clinical research. Three-dimensionally printed models of anatomic and autopsy pathology specimens can be used for demonstrating pathology entities to undergraduate medical, dental, and biomedical students, as well as for postgraduate training in examination of gross specimens for anatomic pathology residents and pathology assistants, aiding clinicopathological correlation at multidisciplinary team meetings, and guiding reconstructive surgical procedures. To apply 3D printing in anatomic pathology for teaching, training, and clinical correlation purposes. Multicolored 3D printing of human anatomic pathology specimens was achieved using a ZCorp 510 3D printer (3D Systems, Rock Hill, South Carolina) following creation of a 3D model using Autodesk 123D Catch software (Autodesk, Inc, San Francisco, California). Three-dimensionally printed models of anatomic pathology specimens created included pancreatoduodenectomy (Whipple operation) and radical nephrectomy specimens. The models accurately depicted the topographic anatomy of selected specimens and illustrated the anatomic relation of excised lesions to adjacent normal tissues. Three-dimensional printing of human anatomic pathology specimens is achievable. Advances in 3D printing technology may further improve the quality of 3D printable anatomic pathology specimens.

  2. Anatomic variation and orgasm: Could variations in anatomy explain differences in orgasmic success?

    PubMed

    Emhardt, E; Siegel, J; Hoffman, L

    2016-07-01

    Though the public consciousness is typically focused on factors such as psychology, penis size, and the presence of the "G-spot," there are other anatomical and neuro-anatomic differences that could play an equal, or more important, role in the frequency and intensity of orgasms. Discovering these variations could direct further medical or procedural management to improve sexual satisfaction. The aim of this study is to review the available literature of anatomical sexual variation and to explain why this variation may predispose some patients toward a particular sexual experience. In this review, we explored the available literature on sexual anatomy and neuro-anatomy. We used PubMed and OVID Medline for search terms, including orgasm, penile size variation, clitoral variation, Grafenberg spot, and benefits of orgasm. First we review the basic anatomy and innervation of the reproductive organs. Then we describe several anatomical variations that likely play a superior role to popular known variation (penis size, presence of g-spot, etc). For males, the delicate play between the parasympathetic and sympathetic nervous systems is vital to achieve orgasm. For females, the autonomic component is more complex. The clitoris is the primary anatomical feature for female orgasm, including its migration toward the anterior vaginal wall. In conclusions, orgasms are complex phenomena involving psychological, physiological, and anatomic variation. While these variations predispose people to certain sexual function, future research should explore how to surgically or medically alter these. Clin. Anat. 29:665-672, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  3. Investigation of topographical anatomy of Broca's area: an anatomic cadaveric study.

    PubMed

    Eser Ocak, Pınar; Kocaelı, Hasan

    2017-04-01

    The sulci constituting the structure of the pars triangularis and opercularis, considered as 'Broca's area', present wide anatomical and morphological variations between different hemispheres. The boundaries are described differently from one another in various studies. The aim of this study was to explore the topographical anatomy, confirm the morphological asymmetry and highlight anatomical variations in Broca's area. This study was performed with 100 hemispheres to investigate the presence, continuity, patterns and connections of the sulcal structures that constitute the morphological asymmetry of Broca's area. Considerable individual anatomical and morphological variations between the inferior frontal gyrus and related sulcal structures were detected. Rare bilateralism findings supported the morphological asymmetry. The inferior frontal sulcus was identified as a single segment in 54 % of the right and two separate segments in 52 % of the left hemispheres, which was the most common pattern. The diagonal sulcus was present in 48 % of the right and 54 % of the left hemispheres. It was most frequently connected to the ascending ramus on both sides. A 'V' shape was observed in 42.5 % of the right hemispheres and a 'Y' shape in 38.3 % of the left hemispheres, which was the most common shape of the pars triangularis. Moreover, the full results are specified in detail. Knowledge of the anatomical variations in this region is indispensable for understanding the functional structure and performing safe surgery. However, most previously published studies have aimed to determine the anatomical asymmetry of the motor speech area without illuminating the topographical anatomy encountered during surgery.

  4. The benefits and limitations of using ultrasonography to supplement anatomical understanding.

    PubMed

    Sweetman, Greg M; Crawford, Gail; Hird, Kathryn; Fear, Mark W

    2013-01-01

    Anatomical understanding is critical to medical education. With reduced teaching time and limited cadaver availability, it is important to investigate how best to utilize in vivo imaging to supplement anatomical understanding and better prepare medical graduates for the proliferation of point-of-care imaging in the future. To investigate whether using short sessions of in vivo imaging using ultrasonography could benefit students' anatomical knowledge and clinical application, we conducted a 2-hour session on abdominal anatomy using ultrasonography in small groups of five to six students, for both first- and second-year student cohorts. Individual feedback was collected to assess student perceptions. To measure retention and understanding, a short examination containing ultrasound images and questions and performance of a clinical skill (gastrointestinal' tract examination) were assessed. Ultrasonography sessions were highly valued by the students, with 90% of the students reporting their understanding was improved, and over 70% reporting increased confidence in their anatomical knowledge. However, the assessments showed no appreciable impact on skills or understanding related to abdominal anatomy and examination. We conclude that the risk associated with limited exposure increasing confidence without increasing skills remains real and that in vivo imaging is not effective when used as a short adjunct teaching tool. The widespread use of ultrasonography means finding the best way to incorporate ultrasound into medical education remains important. To this end, we are currently implementing an extended program including echocardiography and multiple anatomical sessions that will determine if frequency and repetition of use can positively impact on student performance and understanding. Copyright © 2012 American Association of Anatomists.

  5. Esophageal cancer: anatomic particularities, staging, and imaging techniques.

    PubMed

    Encinas de la Iglesia, J; Corral de la Calle, M A; Fernández Pérez, G C; Ruano Pérez, R; Álvarez Delgado, A

    2016-01-01

    Cancer of the esophagus is a tumor with aggressive behavior that is usually diagnosed in advanced stages. The absence of serosa allows it to spread quickly to neighboring mediastinal structures, and an extensive lymphatic drainage network facilitates tumor spread even in early stages. The current TNM classification, harmonized with the classification for gastric cancer, provides new definitions for the anatomic classification, adds non-anatomic characteristics of the tumor, and includes tumors of the gastroesophageal junction. Combining endoscopic ultrasound, computed tomography, positron emission tomography, and magnetic resonance imaging provides greater accuracy in determining the initial clinical stage, and these imaging techniques play an essential role in the selection, planning, and evaluation of treatment. In this article, we review some particularities that explain the behavior of this tumor and we describe the current TNM staging system; furthermore, we discuss the different imaging tests available for its evaluation and include a diagnostic algorithm. Copyright © 2016 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  6. 25 CFR 153.4 - Factors determining competency.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false Factors determining competency. 153.4 Section 153.4 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR LAND AND WATER DETERMINATION OF COMPETENCY: CROW INDIANS § 153.4 Factors determining competency. Among the matters to be considered by the...

  7. A biomechanical assessment of isometric handgrip force and fatigue at different anatomical positions.

    PubMed

    Alkurdi, Ziad D; Dweiri, Yazan M

    2010-05-01

    The present work examined the handgrip force at different anatomical positions for both hands. Anthropometrics, handgrip force, and fatigue were obtained from a representative sample of 20 males randomly selected from the German Jordanian University students. The hand dynamometer first was calibrated with respect to the volunteer's maximal grip strength, and he was then asked to squeeze maximally until the grip force decreased to 50% of its maximal due to fatigue; this test was performed for both hands at different anatomical positions with 2 min of rest for recovery of muscle function. The results showed differences in the handgrip force between subjects of the same anatomical positions and for the different anatomical positions, differences in the time for 50% of the force maximal for both right hand and left hand, higher time required to achieve 50% of maximal handgrip force for the nondominant hand, and maximal handgrip force was obtained when arm adduction with 90 degrees forward at the elbow joint. Recommendations for future work are to measure fatigue time at different percentages, 25%, 50%, 60%, and 75% of maximal force and to investigate the factors affecting handgrip force over a larger sample.

  8. Anatomical distribution and detection rate of colorectal neoplasms according to age in the colonoscopic screening of a Korean population.

    PubMed

    Lee, Suk-Young; Song, Wan Hee; Oh, Sang Cheul; Min, Byung-Wook; Lee, Sun Il

    2018-01-01

    Because data as a basis for the determination of proper age and modality for screening of colorectal neoplasms is lacking, we evaluated detection rates and anatomical distribution of colorectal neoplasms according to age in healthy individuals who underwent total colonoscopy for health checkup. A total of 16,100 cases that had received the colonoscopic examination from January to December in 2014 were analyzed. The total number of individuals who received total colonoscopy were divided by the number of individuals harboring colorectal adenoma to calculate the detection rate of colorectal adenoma. Individuals ≤50 years old were classified as young-age group and aged >50 were old-age group. Differences in anatomical locations of colorectal neoplasms were analyzed in the 2 age groups by chi-square test. Risk factors for colorectal adenoma in each age group were analyzed using univariate and multivariate logistic regression analyses. Detection rates of colorectal adenoma were 13.7% in all cases and 12.8% for those in their 40's. The main anatomical location of colorectal adenoma was proximal colon in both age groups (P < 0.001). Hyperplastic polyp was mainly distributed to the distal colon in both age groups (P < 0.001). Distal colon was the major site for colorectal cancer in the old-age group (P = 0.001). Proximal location of neoplasms was a risk factor for colorectal adenoma in both age groups with multivariate analysis. These data could be the bases for earlier initiation of screening for colorectal neoplasms with total colonoscopy to detect clinically significant colorectal polyps.

  9. Anorectal Cancer: Critical Anatomic and Staging Distinctions That Affect Use of Radiation Therapy

    PubMed Central

    Mamon, Harvey J.; Fuchs, Charles S.; Doyle, Leona A.; Tirumani, Sree Harsha; Ramaiya, Nikhil H.; Rosenthal, Michael H.

    2015-01-01

    Although rectal and anal cancers are anatomically close, they are distinct entities with different histologic features, risk factors, staging systems, and treatment pathways. Imaging is at the core of initial clinical staging of these cancers and most commonly includes magnetic resonance imaging for local-regional staging and computed tomography for evaluation of metastatic disease. The details of the primary tumor and involvement of regional lymph nodes are crucial in determining if and how radiation therapy should be used in treatment of these cancers. Unfortunately, available imaging modalities have been shown to have imperfect accuracy for identification of nodal metastases and imaging features other than size. Staging of nonmetastatic rectal cancers is dependent on the depth of invasion (T stage) and the number of involved regional lymph nodes (N stage). Staging of nonmetastatic anal cancers is determined according to the size of the primary mass and the combination of regional nodal sites involved; the number of positive nodes at each site is not a consideration for staging. Patients with T3 rectal tumors and/or involvement of perirectal, mesenteric, and internal iliac lymph nodes receive radiation therapy. Almost all anal cancers warrant use of radiation therapy, but the extent and dose of the radiation fields is altered on the basis of both the size of the primary lesion and the presence and extent of nodal involvement. The radiologist must recognize and report these critical anatomic and staging distinctions, which affect use of radiation therapy in patients with anal and rectal cancers. ©RSNA, 2015 PMID:26562239

  10. Recent advances in standards for collaborative Digital Anatomic Pathology

    PubMed Central

    2011-01-01

    Context Collaborative Digital Anatomic Pathology refers to the use of information technology that supports the creation and sharing or exchange of information, including data and images, during the complex workflow performed in an Anatomic Pathology department from specimen reception to report transmission and exploitation. Collaborative Digital Anatomic Pathology can only be fully achieved using medical informatics standards. The goal of the international integrating the Healthcare Enterprise (IHE) initiative is precisely specifying how medical informatics standards should be implemented to meet specific health care needs and making systems integration more efficient and less expensive. Objective To define the best use of medical informatics standards in order to share and exchange machine-readable structured reports and their evidences (including whole slide images) within hospitals and across healthcare facilities. Methods Specific working groups dedicated to Anatomy Pathology within multiple standards organizations defined standard-based data structures for Anatomic Pathology reports and images as well as informatic transactions in order to integrate Anatomic Pathology information into the electronic healthcare enterprise. Results The DICOM supplements 122 and 145 provide flexible object information definitions dedicated respectively to specimen description and Whole Slide Image acquisition, storage and display. The content profile “Anatomic Pathology Structured Report” (APSR) provides standard templates for structured reports in which textual observations may be bound to digital images or regions of interest. Anatomic Pathology observations are encoded using an international controlled vocabulary defined by the IHE Anatomic Pathology domain that is currently being mapped to SNOMED CT concepts. Conclusion Recent advances in standards for Collaborative Digital Anatomic Pathology are a unique opportunity to share or exchange Anatomic Pathology structured

  11. Contextual cueing of tactile search is coded in an anatomical reference frame.

    PubMed

    Assumpção, Leonardo; Shi, Zhuanghua; Zang, Xuelian; Müller, Hermann J; Geyer, Thomas

    2018-04-01

    This work investigates the reference frame(s) underlying tactile context memory, a form of statistical learning in a tactile (finger) search task. In this task, if a searched-for target object is repeatedly encountered within a stable spatial arrangement of task-irrelevant distractors, detecting the target becomes more efficient over time (relative to nonrepeated arrangements), as learned target-distractor spatial associations come to guide tactile search, thus cueing attention to the target location. Since tactile search displays can be represented in several reference frames, including multiple external and an anatomical frame, in Experiment 1 we asked whether repeated search displays are represented in tactile memory with reference to an environment-centered or anatomical reference frame. In Experiment 2, we went on examining a hand-centered versus anatomical reference frame of tactile context memory. Observers performed a tactile search task, divided into a learning and test session. At the transition between the two sessions, we introduced postural manipulations of the hands (crossed ↔ uncrossed in Expt. 1; palm-up ↔ palm-down in Expt. 2) to determine the reference frame of tactile contextual cueing. In both experiments, target-distractor associations acquired during learning transferred to the test session when the placement of the target and distractors was held constant in anatomical, but not external, coordinates. In the latter, RTs were even slower for repeated displays. We conclude that tactile contextual learning is coded in an anatomical reference frame. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  12. Dorsal metacarpal veins: anatomic variation and potential clinical implications.

    PubMed

    Elmegarhi, Sara S; Amarin, Justin Z; Hadidi, Maher T; Badran, Darwish H; Massad, Islam M; Bani-Hani, Amjad M; Shatarat, Amjad T

    2018-03-01

    The dorsal metacarpal veins are frequently cannulated. Cannulation success is determined by several variable anatomic features. The objective of this study is to classify, for the first time, the anatomic variants of the dorsal metacarpal veins. In this cross-sectional study, 520 university students and staff were conveniently recruited. The dorsal metacarpal veins in 1040 hands were studied. Venous visibility was enhanced by either tourniquet application or near-infrared illumination. Variant patterns of the dorsal metacarpal veins were classified. The final analysis included 726 hands, for an exclusion rate of 30 %. Eight pattern types were identified. Three anatomic features informed the variation. Bilateral symmetry of the dorsal metacarpal veins was present in 352 participants (83 % of the total). The overall frequency distribution of variants in both hands was similar (P = 0.8). The frequency distribution of variants was subject to sexual dimorphism (P = 0.001), ethnic variation (P < 0.001), and technical variation (P < 0.001). The anatomic variants of the dorsal metacarpal veins were sorted into decreasingly frequent primary, secondary, and tertiary groups. The groups may signify a progressive increase in difficulty of peripheral cannulation, in the mentioned order. As such, primary patterns are the most common and likely the easiest to cannulate, while tertiary patterns are the least common and likely the most difficult to cannulate. The preceding premise, in tandem with the bilateral asymmetry of the veins, is clinically significant. With cannulation difficulty likely signifying an underlying tertiary pattern, the contralateral dorsal metacarpal veins are probabilistically characterized by a primary pattern and are, as such, the easier option for peripheral venous cannulation.

  13. AnatomicalTerms.info: heading for an online solution to the anatomical synonym problem hurdles in data-reuse from the Terminologia Anatomica and the foundational model of anatomy and potentials for future development.

    PubMed

    Gobée, O Paul; Jansma, Daniël; DeRuiter, Marco C

    2011-10-01

    The many synonyms for anatomical structures confuse medical students and complicate medical communication. Easily accessible translations would alleviate this problem. None of the presently available resources-Terminologia Anatomica (TA), digital terminologies such as the Foundational Model of Anatomy (FMA), and websites-are fully satisfactory to this aim. Internet technologies offer new possibilities to solve the problem. Several authors have called for an online TA. An online translation resource should be easily accessible, user-friendly, comprehensive, expandable, and its quality determinable. As first step towards this goal, we built a translation website that we named www.AnatomicalTerms.info, based on the database of the FMA. It translates between English, Latin, eponyms, and to a lesser extent other languages, and presently contains over 31,000 terms for 7,250 structures, covering 95% of TA. In addition, it automatically presents searches for images, documents and anatomical variations regarding the sought structure. Several terminological and conceptual issues were encountered in transferring data from TA and FMA into AnatomicalTerms.info, resultant from these resources' different set-ups (paper versus digital) and targets (machine versus human-user). To the best of our knowledge, AnatomicalTerms.info is unique in its combination of user-friendliness and comprehensiveness. As next step, wiki-like expandability will be added to enable open contribution of clinical synonyms and terms in different languages. Specific quality measures will be taken to strike a balance between open contribution and quality assurance. AnatomicalTerms.info's mechanism that "translates" terms to structures furthermore may enhance targeted searching by linking images, descriptions, and other anatomical resources to the structures. Copyright © 2011 Wiley-Liss, Inc.

  14. Anatomical terminology, then and now.

    PubMed

    O'Rahilly, R

    1989-01-01

    Anatomical terminology, which had become chaotic by the nineteenth century, was codified in the BNA of 1895, when some 5,000 terms were carefully selected from among approximately 50,000 names. The BNA and its three major revisions (BR, INA, PNA) are here reviewed and placed in historical perspective. It is emphasized that many anatomical terms are very ancient and that the various nomenclatures are not 'new terminologies' but rather, for the most part, selections of already existing names. This can be seen clearly in the naming of the cranial nerves. Another example, the carpal and tarsal bones, is analysed in detail. Of the 8 carpal bones, for instance, the current names for 7 of them are those proposed by Henle in 1855. All the nomenclatures are, as they should be, in Latin, but it is understood that translations of many terms into other languages are necessary. Although views pro and con have been expressed, current usage favours the erect posture and the anatomical position as a basis, as well as the elimination of eponyms. In both teaching and research, the Nomina has been of great benefit in reducing drastically the number of unnecessary synonyms and in providing a coherent, internationally accepted system that is now the standard in anatomical textbooks. Hence, further use of the Nomina should be encouraged.

  15. Anatomical eponyms - unloved names in medical terminology.

    PubMed

    Burdan, F; Dworzański, W; Cendrowska-Pinkosz, M; Burdan, M; Dworzańska, A

    2016-01-01

    Uniform international terminology is a fundamental issue of medicine. Names of various organs or structures have developed since early human history. The first proper anatomical books were written by Hippocrates, Aristotle and Galen. For this reason the modern terms originated from Latin or Greek. In a modern time the terminology was improved in particular by Vasalius, Fabricius and Harvey. Presently each known structure has internationally approved term that is explained in anatomical or histological terminology. However, some elements received eponyms, terms that incorporate the surname of the people that usually describe them for the first time or studied them (e.g., circle of Willis, follicle of Graff, fossa of Sylvious, foramen of Monro, Adamkiewicz artery). Literature and historical hero also influenced medical vocabulary (e.g. Achilles tendon and Atlas). According to various scientists, all the eponyms bring colour to medicine, embed medical traditions and culture to our history but lack accuracy, lead of confusion, and hamper scientific discussion. The current article presents a wide list of the anatomical eponyms with their proper anatomical term or description according to international anatomical terminology. However, since different eponyms are used in various countries, the list could be expanded.

  16. Factors determining lumber recovery in sawmilling

    Treesearch

    Philip H. Steele

    1984-01-01

    Lumber volume recovery in sawmilling is determined by a confusing interaction of several factors. The more one knows about each individual factor, the more one can understand how the factors interact. The author identifies and discusses in detail seven factors influencing lumber recovery. Past and current research is cited, and examples are given to illustrate the...

  17. Determinants of the electric field during transcranial direct current stimulation.

    PubMed

    Opitz, Alexander; Paulus, Walter; Will, Susanne; Antunes, Andre; Thielscher, Axel

    2015-04-01

    Transcranial direct current stimulation (tDCS) causes a complex spatial distribution of the electric current flow in the head which hampers the accurate localization of the stimulated brain areas. In this study we show how various anatomical features systematically shape the electric field distribution in the brain during tDCS. We constructed anatomically realistic finite element (FEM) models of two individual heads including conductivity anisotropy and different skull layers. We simulated a widely employed electrode montage to induce motor cortex plasticity and moved the stimulating electrode over the motor cortex in small steps to examine the resulting changes of the electric field distribution in the underlying cortex. We examined the effect of skull thickness and composition on the passing currents showing that thinner skull regions lead to higher electric field strengths. This effect is counteracted by a larger proportion of higher conducting spongy bone in thicker regions leading to a more homogenous current over the skull. Using a multiple regression model we could identify key factors that determine the field distribution to a significant extent, namely the thicknesses of the cerebrospinal fluid and the skull, the gyral depth and the distance to the anode and cathode. These factors account for up to 50% of the spatial variation of the electric field strength. Further, we demonstrate that individual anatomical factors can lead to stimulation "hotspots" which are partly resistant to electrode positioning. Our results give valuable novel insights in the biophysical foundation of tDCS and highlight the importance to account for individual anatomical factors when choosing an electrode montage. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Creation of anatomical models from CT data

    NASA Astrophysics Data System (ADS)

    Alaytsev, Innokentiy K.; Danilova, Tatyana V.; Manturov, Alexey O.; Mareev, Gleb O.; Mareev, Oleg V.

    2018-04-01

    Computed tomography is a great source of biomedical data because it allows a detailed exploration of complex anatomical structures. Some structures are not visible on CT scans, and some are hard to distinguish due to partial volume effect. CT datasets require preprocessing before using them as anatomical models in a simulation system. The work describes segmentation and data transformation methods for an anatomical model creation from the CT data. The result models may be used for visual and haptic rendering and drilling simulation in a virtual surgery system.

  19. Embryologic and anatomic basis of inguinal herniorrhaphy.

    PubMed

    Skandalakis, J E; Colborn, G L; Androulakis, J A; Skandalakis, L J; Pemberton, L B

    1993-08-01

    The embryology and surgical anatomy of the inguinal area is presented with emphasis on embryologic and anatomic entities related to surgery. We have presented the factors, such as patent processus vaginalis and defective posterior wall of the inguinal canal, that may be responsible for the genesis of congenital inguinofemoral herniation. These, together with impaired collagen synthesis and trauma, are responsible for the formation of the acquired inguinofemoral hernia. Still, we do not have all the answers for an ideal repair. Despite the latest successes in repair, we, to paraphrase Ritsos, are awaiting the triumphant return of Theseus.

  20. Factors affecting anatomical region of injury, severity, and mortality for road trauma in a high-income developing country: lessons for prevention.

    PubMed

    Eid, Hani O; Barss, Peter; Adam, Shehabeldin H; Torab, Fawaz Chikh; Lunsjo, Karl; Grivna, Michal; Abu-Zidan, Fikri M

    2009-07-01

    To study the factors affecting anatomical region of injury, severity, and mortality among road users in United Arab Emirates so as to improve preventive measures. Data of the Trauma Registry of Al Ain city were collected prospectively over 3 years (2003-2006) at the main trauma hospital. For traffic injuries, the following were assessed: gender, nationality, road user type, anatomical region(s) of injury, systolic blood pressure on admission, Glasgow Coma Scale (GCS), Injury Severity Score (ISS), and mortality. Analysis included frequencies, cross-tabulations, and logistic regression. There were 1070 patients, 89% male, 25% UAE nationals, and with a mean age of 31 years. Expatriates, mainly from non-Arabic speaking, low-income countries, accounted for 88% of injured pedestrians, whilst nationals were overrepresented among vehicle occupants (29%), and motorcyclists 37%. Injuries of the extremities and head were frequent among pedestrians, motorcyclists, and bicyclists, whilst head and spine injuries were most common among front and rear vehicle occupants and drivers. The median ISS was five for pedestrians and four for all other road user types, including rear vehicle occupants. The mean hospitalisation was 9.7 days; 13% of patients were admitted to ICU with mean stay of 6.5 days. Overall mortality was 4%; pedestrians accounted for 61% of deaths. Predictors of mortality were GCS (p<0.001), ISS (p<0.01) and systolic blood pressure on admission (p<0.03). Head injury was a major factor affecting mortality, followed by injury severity and hypotension. To reduce injury incidence and severity, legislation and education are needed to ensure use of seat belts by all vehicle occupants including rear passengers, high-visibility devices by other road users, helmets by motorcyclists and bicyclists, protective clothing and boots for motorcyclists, and traffic engineering for pedestrians.

  1. Anatomical Basis for the Cardiac Interventional Electrophysiologist

    PubMed Central

    Sánchez-Quintana, Damián; Doblado-Calatrava, Manuel; Cabrera, José Angel; Macías, Yolanda; Saremi, Farhood

    2015-01-01

    The establishment of radiofrequency catheter ablation techniques as the mainstay in the treatment of tachycardia has renewed new interest in cardiac anatomy. The interventional arrhythmologist has drawn attention not only to the gross anatomic details of the heart but also to architectural and histological characteristics of various cardiac regions that are relevant to the development or recurrence of tachyarrhythmias and procedural related complications of catheter ablation. In this review, therefore, we discuss some anatomic landmarks commonly used in catheter ablations including the terminal crest, sinus node region, Koch's triangle, cavotricuspid isthmus, Eustachian ridge and valve, pulmonary venous orifices, venoatrial junctions, and ventricular outflow tracts. We also discuss the anatomical features of important structures in the vicinity of the atria and pulmonary veins, such as the esophagus and phrenic nerves. This paper provides basic anatomic information to improve understanding of the mapping and ablative procedures for cardiac interventional electrophysiologists. PMID:26665006

  2. Muscle length changes during swimming in scup: sonomicrometry verifies the anatomical high-speed cine technique.

    PubMed

    Coughlin, D J; Valdes, L; Rome, L C

    1996-02-01

    Recent attempts to determine how fish muscles are used to power swimming have employed the work loop technique (driving isolated muscles using their in vivo strain and stimulation pattern). These muscle strains have in turn been determined from the anatomical high-speed cine technique. In this study, we used an independent technique, sonomicrometry, to attempt to verify these strain measurements and the conclusions based on them. We found that the strain records measured from sonomicrometry and the anatomical-cine techniques were very similar. The ratio of the strain measured from sonomicrometry to that from the anatomical-cine technique was remarkably close to unity (1.046 +/- 0.013, mean +/- S.E.M., N = 15, for transducers placed on the muscle surface and corrected for muscle depth, and 0.921 +/- 0.028, N = 8, in cases where the transducers were inserted to the average depth of the red muscle). These measurements also showed that red muscle shortening occurs simultaneously with local backbone curvature, unlike previous results which suggested that white muscle shortening during the escape response occurs prior to the change in local backbone curvature.

  3. Anatomic determination of optimal entry point and direction for C1 lateral mass screw placement.

    PubMed

    Blagg, Stuart E; Don, Angus S; Robertson, Peter A

    2009-06-01

    Anatomic study of C1 osteology using computerized tomography. To define the anatomy of the C1 lateral mass and make recommendations for optimal entry point and screw placement at C1. C1 lateral mass screw fixation is a reliable biomechanical technique that gives equivalent stability to that of Magerl transarticular screw fixation combined with posterior wiring for C1-C2 fusion. Use of a lateral mass screw allows alternative stabilization constructs to the transarticular technique when C2 vertebral artery anatomy is unfavorable. Because the vertebral artery travels lateral to the lateral mass, then crosses medially over the C1 neural arch, it is at risk during instrumentation. Medially, the cord and canal contents are at risk. While the anatomy of the C1 vertebra and lateral mass is well known, specific definition of ideal entry points, screw pathway direction, and dimensions of screws requires further clarification to enable a clinically safe surgical technique. Fifty consecutive patients underwent computerized tomography scans of their cervical spine. Using calibrated scans, measurements were taken to give the average dimensions of the C1 vertebra with a view for insertion of lateral mass screws beneath the posterior arch. The range of anatomic dimensions was examined to assess risk of vertebral artery damage in this population. The average length of screw within the lateral mass is 17.9 mm with 21.5 mm of screw posterior to the lateral mass, necessary to allow rod placement posteriorly. The safest entry point was directly beneath the medial edge of the posterior arch/lamina where it joins the lateral mass. The ideal direction of screw angulation in the sagittal plane was parallel to the posterior arch of C1. In the medial lateral plane, direct anterior placement could be used, but the lateral mass will tolerate 20 degrees of medial angulation from this starting point. The average distance between the vertebral artery foramen laterally and the screw pathway was 8

  4. [Ten years after the latest revision International Anatomical Terminology].

    PubMed

    Kachlík, D; Bozdechová, I; Cech, P; Musil, V; Báca, V

    2008-01-01

    Ten years ago, the latest revision of the Latin anatomical nomenclature was approved and published as Terminologia Anatomica (International Anatomical Terminology), and is acknowledged by the organization uniting national anatomical societies--International Federation of Associations of Anatomists. The authors concentrate on new terms included in the nomenclature and on the linguistic changes of terminology. The most frequent errors done by medical specialists in the usage of the Latin anatomical terminology are emphasized and the situation of eponyms in contemporary anatomy is discussed in detail as well. The last version of the nomenclature makes its way very slowly in the professional community and it is necessary to refer to positive changes and advantages it has brought. The usage of this Latin anatomical nomenclature version is suggested by the International Federation to follow in theoretical and clinical fields of medicine. The authors of the article strongly recommend using the recent revision of the Latin anatomical nomenclature both in the oral and written forms, when educating and publishing.

  5. Haemodynamic and anatomic progression of aortic stenosis.

    PubMed

    Nguyen, Virginia; Cimadevilla, Claire; Estellat, Candice; Codogno, Isabelle; Huart, Virginie; Benessiano, Joelle; Duval, Xavier; Pibarot, Philippe; Clavel, Marie Annick; Enriquez-Sarano, Maurice; Vahanian, Alec; Messika-Zeitoun, David

    2015-06-01

    Aortic valve stenosis (AS) is a progressive disease, but the impact of baseline AS haemodynamic or anatomic severity on AS progression remains unclear. In 149 patients (104 mild AS, 36 moderate AS and 9 severe AS) enrolled in 2 ongoing prospective cohorts (COFRASA/GENERAC), we evaluated AS haemodynamic severity at baseline and yearly, thereafter, using echocardiography (mean pressure gradient (MPG)) and AS anatomic severity using CT (degree of aortic valve calcification (AVC)). After a mean follow-up of 2.9±1.0 years, mean MGP increased from 22±11 to 30±16 mm Hg (+3±3 mm Hg/year), and mean AVC from 1108±891 to 1640±1251 AU (arbitrary units) (+188±176 AU/year). Progression of AS was strongly related to baseline haemodynamic severity (+2±3 mm Hg/year in mild AS, +4±3 mm Hg/year in moderate AS and +5±5 mm Hg/year in severe AS (p=0.01)), and baseline haemodynamic severity was an independent predictor of haemodynamic progression (p=0.0003). Annualised haemodynamic and anatomic progression rates were significantly correlated (r=0.55, p<0.0001), but AVC progression rate was also significantly associated with baseline haemodynamic severity (+141±133 AU/year in mild AS, +279±189 AU/year in moderate AS and +361±293 AU/year in severe AS, p<0.0001), and both baseline MPG and baseline AVC were independent determinants of AVC progression (p<0.0001). AS progressed faster with increasing haemodynamic or anatomic severity. Our results suggest that a medical strategy aimed at preventing AVC progression may be useful in all subsets of patients with AS including those with severe AS and support the recommended closer follow-up of patients with AS as AS severity increases. COFRASA (clinicalTrial.gov number NCT 00338676) and GENERAC (clinicalTrial.gov number NCT00647088). Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  6. [Histo-anatomical researches of two subspecies of Lavandula angustifolia Mill].

    PubMed

    Robu, Silvia; Galeş, Ramona; Toma, C; Stănescu, Ursula

    2011-01-01

    The structure of the inflorescences of two subspecies of Lavandula angustifolia sL. angustifolia ssp. angustifolia and. L. angustifolia ssp. pyrenaica (D.C.) Guineaţ was studied to determine the range of variation in certain histo-anatomical characters. The flower and leaf structure has been analysed on cross and superficial section using the usual techniques and methods applied in plant histo-anatomical research. In cross-section, inflorescence axis has a squared-shape contour, with four proeminent ribs. On the epiderme of inflorescence axis there are present stomata, trichoms and secretory hairs. The trichoms are pluricelullar and T-branched. The secretory hairs have a short pedicel and a uni-or bicellular head. The study revealed that there are only quantitative differences, referring to the degree of sclerification and lignification of mechanical elements and the size of the vascular bundles.

  7. Development of a quantitative multivariable radiographic method to evaluate anatomic changes associated with laminitis in the forefeet of donkeys.

    PubMed

    Collins, Simon N; Dyson, Sue J; Murray, Rachel C; Newton, J Richard; Burden, Faith; Trawford, Andrew F

    2012-08-01

    To establish and validate an objective method of radiographic diagnosis of anatomic changes in laminitic forefeet of donkeys on the basis of data from a comprehensive series of radiographic measurements. 85 donkeys with and 85 without forelimb laminitis for baseline data determination; a cohort of 44 donkeys with and 18 without forelimb laminitis was used for validation analyses. For each donkey, lateromedial radiographic views of 1 weight-bearing forelimb were obtained; images from 11 laminitic and 2 nonlaminitic donkeys were excluded (motion artifact) from baseline data determination. Data from an a priori selection of 19 measurements of anatomic features of laminitic and nonlaminitic donkey feet were analyzed by use of a novel application of multivariate statistical techniques. The resultant diagnostic models were validated in a blinded manner with data from the separate cohort of laminitic and nonlaminitic donkeys. Data were modeled, and robust statistical rules were established for the diagnosis of anatomic changes within laminitic donkey forefeet. Component 1 scores ≤ -3.5 were indicative of extreme anatomic change, and scores from -2.0 to 0.0 denoted modest change. Nonlaminitic donkeys with a score from 0.5 to 1.0 should be considered as at risk for laminitis. Results indicated that the radiographic procedures evaluated can be used for the identification, assessment, and monitoring of anatomic changes associated with laminitis. Screening assessments by use of this method may enable early detection of mild anatomic change and identification of at-risk donkeys.

  8. Anatomic and isometric points on femoral attachment site of popliteus muscle-tendon complex for the posterolateral corner reconstruction.

    PubMed

    Yang, Jae-Hyuk; Lim, Hong Chul; Bae, Ji Hoon; Fernandez, Harry; Bae, Tae Soo; Wang, Joon Ho

    2011-10-01

    Descriptive laboratory study. The femoral anatomic insertion site and the optimal isometric point of popliteus tendon for posterolateral reconstruction are not well known. Purpose of this study was to determine the relative relationship between the femoral anatomic insertion and isometric point of popliteus muscle-tendon complex with the lateral epicondyle of femur. Thirty unpaired cadaveric knees were dissected to determine the anatomic femoral insertion of the popliteus tendon. The distance and the angle from the lateral epicondyle of femur to the center of the anatomic insertion of the popliteus tendon were measured using digital caliper and goniometer. Eight unpaired fresh cadaveric knees were examined to determine the optimal isometric point of femoral insertion of popliteus tendon using computer-controlled motion capture analysis system (Motion Analysis, CA, USA). Distances from targeted tibial tunnel for popliteus tendon reconstruction to the 35 points gained on the lateral surface of femur were recorded at 0, 30, 60, 90, and 120° knee flexion. A point with the least excursion (<2.0 mm) was determined as the isometric point. The center of anatomic insertion points and the optimal isometric point for the main fibers of popliteus tendon were found to be posterior and distal to the lateral epicondyle of femur. The distance from the lateral epicondyle of femur to the center of anatomic femoral insertion of popliteus tendon was 11.3 ± 1.2 mm (mean ± SD). The angle between long axis of femur and the line from lateral epicondyle of femur to anatomic femoral insertion of popliteus tendon was 31.4 ± 5.3°. The isometric points for the femoral insertion of popliteus muscle-tendon complex were situated posterior and distal to the lateral epicondyle in all 8 knees. The distance between the least excursion point and the lateral epicondyle was calculated as 10.4 ± 1.7 mm. The angle between the long axis of femur and the line from lateral epicondyle of

  9. Automated anatomical labeling method for abdominal arteries extracted from 3D abdominal CT images

    NASA Astrophysics Data System (ADS)

    Oda, Masahiro; Hoang, Bui Huy; Kitasaka, Takayuki; Misawa, Kazunari; Fujiwara, Michitaka; Mori, Kensaku

    2012-02-01

    This paper presents an automated anatomical labeling method of abdominal arteries. In abdominal surgery, understanding of blood vessel structure concerning with a target organ is very important. Branching pattern of blood vessels differs among individuals. It is required to develop a system that can assist understanding of a blood vessel structure and anatomical names of blood vessels of a patient. Previous anatomical labbeling methods for abdominal arteries deal with either of the upper or lower abdominal arteries. In this paper, we present an automated anatomical labeling method of both of the upper and lower abdominal arteries extracted from CT images. We obtain a tree structure of artery regions and calculate feature values for each branch. These feature values include the diameter, curvature, direction, and running vectors of a branch. Target arteries of this method are grouped based on branching conditions. The following processes are separately applied for each group. We compute candidate artery names by using classifiers that are trained to output artery names. A correction process of the candidate anatomical names based on the rule of majority is applied to determine final names. We applied the proposed method to 23 cases of 3D abdominal CT images. Experimental results showed that the proposed method is able to perform nomenclature of entire major abdominal arteries. The recall and the precision rates of labeling are 79.01% and 80.41%, respectively.

  10. Final anatomic and visual outcomes appear independent of duration of silicone oil intraocular tamponade in complex retinal detachment surgery.

    PubMed

    Rhatigan, Maedbh; McElnea, Elizabeth; Murtagh, Patrick; Stephenson, Kirk; Harris, Elaine; Connell, Paul; Keegan, David

    2018-01-01

    To report anatomic and visual outcomes following silicone oil removal in a cohort of patients with complex retinal detachment, to determine association between duration of tamponade and outcomes and to compare patients with oil removed and those with oil in situ in terms of demographic, surgical and visual factors. We reported a four years retrospective case series of 143 patients with complex retinal detachments who underwent intraocular silicone oil tamponade. Analysis between anatomic and visual outcomes, baseline demographics, duration of tamponade and number of surgical procedures were carried out using Fisher's exact test and unpaired two-tailed t -test. One hundred and six patients (76.2%) had undergone silicone oil removal at the time of review with 96 patients (90.6%) showing retinal reattachment following oil removal. Duration of tamponade was not associated with final reattachment rate or with a deterioration in best corrected visual acuity (BCVA). Patients with oil removed had a significantly better baseline and final BCVA compared to those under oil tamponade ( P =0.0001, <0.0001 respectively). Anatomic and visual outcomes in this cohort are in keeping with those reported in the literature. Favorable outcomes were seen with oil removal but duration of oil tamponade does not affect final attachment rate with modern surgical techniques and should be managed on a case by case basis.

  11. Anatomical parameterization for volumetric meshing of the liver

    NASA Astrophysics Data System (ADS)

    Vera, Sergio; González Ballester, Miguel A.; Gil, Debora

    2014-03-01

    A coordinate system describing the interior of organs is a powerful tool for a systematic localization of injured tissue. If the same coordinate values are assigned to specific anatomical landmarks, the coordinate system allows integration of data across different medical image modalities. Harmonic mappings have been used to produce parametric coordinate systems over the surface of anatomical shapes, given their flexibility to set values at specific locations through boundary conditions. However, most of the existing implementations in medical imaging restrict to either anatomical surfaces, or the depth coordinate with boundary conditions is given at sites of limited geometric diversity. In this paper we present a method for anatomical volumetric parameterization that extends current harmonic parameterizations to the interior anatomy using information provided by the volume medial surface. We have applied the methodology to define a common reference system for the liver shape and functional anatomy. This reference system sets a solid base for creating anatomical models of the patient's liver, and allows comparing livers from several patients in a common framework of reference.

  12. Interpreting and Integrating Clinical and Anatomic Pathology Results.

    PubMed

    Ramaiah, Lila; Hinrichs, Mary Jane; Skuba, Elizabeth V; Iverson, William O; Ennulat, Daniela

    2017-01-01

    The continuing education course on integrating clinical and anatomical pathology data was designed to communicate the importance of using a weight of evidence approach to interpret safety findings in toxicology studies. This approach is necessary, as neither clinical nor anatomic pathology data can be relied upon in isolation to fully understand the relationship between study findings and the test article. Basic principles for correlating anatomic pathology and clinical pathology findings and for integrating these with other study end points were reviewed. To highlight these relationships, a series of case examples, presented jointly by a clinical pathologist and an anatomic pathologist, were used to illustrate the collaborative effort required between clinical and anatomical pathologists. In addition, the diagnostic utility of traditional liver biomarkers was discussed using results from a meta-analysis of rat hepatobiliary marker and histopathology data. This discussion also included examples of traditional and novel liver and renal biomarker data implementation in nonclinical toxicology studies to illustrate the relationship between discrete changes in biochemistry and tissue morphology.

  13. Lip sun protection factor of a lipstick sunscreen.

    PubMed

    Gabard, B; Ademola, J

    2001-01-01

    There is a well-documented need for effective human UVA and UVB photoprotection. Since there are important anatomical variations, the sun protection factor (SPF) of a lipstick sunscreen was measured on the anatomical site intended for use. The SPF tests were performed according to Federal US and European COLIPA guidelines. Prior to performing a test on the lip, the minimal erythemal dose (MED) of the unprotected back skin was determined. Subsequently, the sunscreen SPF was measured on the anatomical target site (lip). The evaluator was blinded with respect to scoring the SPF of each sunscreen treatment. Individual test sites were assigned to one of the following treatment conditions: (1) no treatment (MED of unprotected skin); (2) test formulation; (3) reference standard. The MED on unprotected back skin was found to be 25% lower than on unprotected lip skin. The SPF of the lipstick sunscreen was measured 2 units lower than the SPF determined in the classical way on the back skin. It was hypothesized that the higher MED of the lower lip compared with back skin was due to the adaptation of this tissue to the continuous exposure to UV radiation. Copyright 2001 S. Karger AG, Basel

  14. Standards to support information systems integration in anatomic pathology.

    PubMed

    Daniel, Christel; García Rojo, Marcial; Bourquard, Karima; Henin, Dominique; Schrader, Thomas; Della Mea, Vincenzo; Gilbertson, John; Beckwith, Bruce A

    2009-11-01

    Integrating anatomic pathology information- text and images-into electronic health care records is a key challenge for enhancing clinical information exchange between anatomic pathologists and clinicians. The aim of the Integrating the Healthcare Enterprise (IHE) international initiative is precisely to ensure interoperability of clinical information systems by using existing widespread industry standards such as Digital Imaging and Communication in Medicine (DICOM) and Health Level Seven (HL7). To define standard-based informatics transactions to integrate anatomic pathology information to the Healthcare Enterprise. We used the methodology of the IHE initiative. Working groups from IHE, HL7, and DICOM, with special interest in anatomic pathology, defined consensual technical solutions to provide end-users with improved access to consistent information across multiple information systems. The IHE anatomic pathology technical framework describes a first integration profile, "Anatomic Pathology Workflow," dedicated to the diagnostic process including basic image acquisition and reporting solutions. This integration profile relies on 10 transactions based on HL7 or DICOM standards. A common specimen model was defined to consistently identify and describe specimens in both HL7 and DICOM transactions. The IHE anatomic pathology working group has defined standard-based informatics transactions to support the basic diagnostic workflow in anatomic pathology laboratories. In further stages, the technical framework will be completed to manage whole-slide images and semantically rich structured reports in the diagnostic workflow and to integrate systems used for patient care and those used for research activities (such as tissue bank databases or tissue microarrayers).

  15. Anatomical features of skull base and oral cavity: a pilot study to determine the accessibility of the sella by transoral robotic-assisted surgery.

    PubMed

    Amelot, Aymeric; Trunet, Stephanie; Degos, Vincent; André, Olivier; Dionnet, Aurore; Cornu, Philippe; Hans, Stéphane; Chauvet, Dorian

    2015-10-01

    The role of transoral robotic surgery (TORS) in the skull base emerges and represents the natural progression toward miniinvasive resections in confined spaces. The accessibility of the sella via TORS has been recently described on fresh human cadavers. An anatomic study is mandatory to know if this approach would be feasible in the majority of patients regardless of their oral morphological features. From 30 skull base CT scans from patients who were asked to open their mouth as wide as they can, we measured specific dimensions of the oral cavity and the skull base, such as length of the palate, mouth opening and distance from the sella to the palate. All data were acquired on a sagittal midline plane and on a 25° rotation plane, which simulated the axis of the robotic instruments. Looking at the projection of the dental palatine line on the sella, we studied possible predictive factors of sellar accessibility and tried to bring objective data for surgical feasibility. We also proposed an angle α to study the working angle at the skull base. We observed that the maximal mouth opening was a good predictive factor of sellar accessibility by TORS (p < 0.05). The mouth aperture threshold value for a good sensitivity, over 80 %, was comparable to the mean value of mouth opening in our series, 38.9 and 39.4 mm respectively. Moreover, we showed a statistically significant increase of the working angle α at the skull base comparing the lateral access to the midline one (p < 0.05). This seemed to quantitatively demonstrate that the robotic arms placed at the labial commissure of the mouth can reach the sella. From these anatomical features and previous cadaveric dissections, we assume that TORS may be feasible on a majority of patients to remove pituitary adenomas.

  16. Soft tissue displacement over pelvic anatomical landmarks during 3-D hip movements.

    PubMed

    Camomilla, V; Bonci, T; Cappozzo, A

    2017-09-06

    The position, in a pelvis-embedded anatomical coordinate system, of skin points located over the following anatomical landmarks (AL) was determined while the hip assumed different spatial postures: right and left anterior superior and posterior superior iliac spines, and the sacrum. Postures were selected as occurring during walking and during a flexion-extension and circumduction movement, as used to determine the hip joint centre position (star-arc movement). Five volunteers, characterised by a wide range of body mass indices (22-37), were investigated. Subject-specific MRI pelvis digital bone models were obtained. For each posture, the pose of the pelvis-embedded anatomical coordinate system was determined by registering this bone model with points digitised over bony prominences of the pelvis, using a wand carrying a marker-cluster and stereophotogrammetry. The knowledge of how the position of the skin points varies as a function of the hip posture provided information regarding the soft tissue artefact (STA) that would affect skin markers located over those points during stereophotogrammetric movement analysis. The STA was described in terms of amplitude (relative to the position of the AL during an orthostatic posture), diameter (distance between the positions of the AL which were farthest away from each other), and pelvis orientation. The STA amplitude, exhibited, over all postures, a median [inter-quartile] value of 9[6] and 16[11]mm, for normal and overweight volunteers, respectively. STA diameters were larger for the star-arc than for the walking postures, and the direction was predominantly upwards. Consequent errors in pelvic orientation were in the range 1-9 and 4-11 degrees, for the two groups respectively. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. [Mediaeval anatomic iconography (Part II)].

    PubMed

    Barg, L

    1996-01-01

    In the second part of his paper the author has presented a mediaeval anatomical draft based on empirical studies. From the first drawings from XVth century showing the places of blood-letting and connected with astrological prognostics, to systematical drawings by Guido de Vigevano. He has stressed the parallel existence of two lines of teaching anatomy; one based on philosophical concepts (discussed in the first part of paper), the second one based on empirical concepts. The latter trend has formed the grounds for final transformation, which has taken place in anatomical science in age of Renaissance.

  18. The current and ideal state of anatomic pathology patient safety.

    PubMed

    Raab, Stephen Spencer

    2014-01-01

    An anatomic pathology diagnostic error may be secondary to a number of active and latent technical and/or cognitive components, which may occur anywhere along the total testing process in clinical and/or laboratory domains. For the pathologist interpretive steps of diagnosis, we examine Kahneman's framework of slow and fast thinking to explain different causes of error in precision (agreement) and in accuracy (truth). The pathologist cognitive diagnostic process involves image pattern recognition and a slow thinking error may be caused by the application of different rationally-constructed mental maps of image criteria/patterns by different pathologists. This type of error is partly related to a system failure in standardizing the application of these maps. A fast thinking error involves the flawed leap from image pattern to incorrect diagnosis. In the ideal state, anatomic pathology systems would target these cognitive error causes as well as the technical latent factors that lead to error.

  19. Brain Morphometry Using Anatomical Magnetic Resonance Imaging

    ERIC Educational Resources Information Center

    Bansal, Ravi; Gerber, Andrew J.; Peterson, Bradley S.

    2008-01-01

    The efficacy of anatomical magnetic resonance imaging (MRI) in studying the morphological features of various regions of the brain is described, also providing the steps used in the processing and studying of the images. The ability to correlate these features with several clinical and psychological measures can help in using anatomical MRI to…

  20. Anatomic documentation of the G-spot complex role in the genesis of anterior vaginal wall ballooning.

    PubMed

    Ostrzenski, Adam

    2014-09-01

    To expand previous G-spot anatomical and histological investigations; to examine the G-spot complex anatomic role in the anterior vaginal wall ballooning bio-mechanisms; and to determine, which division of autonomic nervous system (sympathetic or parasympathetic) dominates at the time of female sudden death. A prospective-descriptive case series anatomical study on eleven consecutive fresh humane female cadavers was conducted. Anterior vaginal wall stratum-by-stratum macro-dissections were executed in axial, coronal and sagittal plains. Upon G-spot extirpations, micro-dissections were performed. The G-spot tissues were stained with hematoxilin and eosin for histological examinations to authenticate the G-spot anatomical and histological characteristic features. The G-spot complex was identified and present in all subjects on either the distal vaginal left (more often) or on the right side from the lateral margin of the urethra; the G-spot anatomical and microscopic characteristic features have been authenticated; the G-spot complex expansion elevated anterior vaginal walls in each subject; the autonomic parasympathetic nervous system was the dominant division at the time of female subject sudden death. This study advances our anatomical and histological understanding of the G-spot complex and its role in the genesis of anterior vaginal ballooning bio-mechanisms. The G-spot complex is under parasympathetic nervous system domination at the time of female sudden death. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  1. A theoretical analysis of anatomical and functional intestinal slow wave re-entry.

    PubMed

    Du, Peng; O'Grady, Gregory; Cheng, Leo K

    2017-07-21

    Intestinal bioelectrical slow waves are a key regulator of intestinal motility. Peripheral pacemakers, ectopic initiations and sustained periods of re-entrant activities have all been experimentally observed to be important factors in setting the frequency of intestinal slow waves, but the tissue-level mechanisms underpinning these activities are unclear. This theoretical analysis aimed to define the initiation, maintenance, and termination criteria of two classes of intestinal re-entrant activities: anatomical re-entry and functional re-entry. Anatomical re-entry was modeled in a three-dimensional (3D) cylindrical model, and functional rotor was modeled in a 2D rectangle model. A single-pulse stimulus was used to invoke an anatomical re-entry and a prolonged refractory block was used to invoke the rotor. In both cases, the simulated re-entrant activities operated at frequencies above the baseline entrainment frequency. The anatomical re-entry simulation results demonstrated that a temporary functional refractory block would be required to initiate the re-entrant activity in a single direction around the cylindrical model. The rotor could be terminated by a single-pulse stimulus delivered around the core of the rotor. In conclusion, the simulation results provide the following new insights into the mechanisms of intestinal re-entry: (i) anatomical re-entry is only maintained within a specific range of velocities, outside of which the re-entrant activities become either an ectopic activity or simultaneous activations of the intestinal wall; (ii) a maintained rotor entrained slow waves faster in the antegrade direction than in the retrograde direction. Simulations are shown to be a valuable tool for achieving novel insights into the mechanisms of intestinal slow wave dysrhythmia. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Lateral Patellofemoral Ligament: An Anatomic Study.

    PubMed

    Shah, Kalpit N; DeFroda, Steven F; Ware, James Kristopher; Koruprolu, Sarath C; Owens, Brett D

    2017-12-01

    Medial instability of the patellofemoral joint is a rare but known phenomenon that may result from an incompetent lateral patellofemoral ligament (LPFL). Surgical reconstruction of the LPFL has been described. However, anatomic details of the ligament have not been the subject of scrutiny. To describe the anatomic origin and insertion of the LPFL. Descriptive laboratory study. Ten fresh-frozen, unpaired human cadaveric knees (mean age, 57 years) were dissected to identify the LPFL. The dissection was carried out by elevating the iliotibial band to expose the deep capsular layer of the knee joint, followed by a medial parapatellar approach to the knee. Then the quadriceps and patellar tendons were sectioned, and the LPFL was isolated by visualization and palpation. The LPFL was dissected to reveal its origin and insertion; these were measured with respect to the lateral epicondyle and the superior-inferior axis of the lateral patella, respectively. On average, the LPFL had a variable point of origin in location as well as width about the lateral epicondyle. The LPFL originated, on average, 2.6 mm distal (range, 13.1 mm proximal to 11.4 mm distal) and 10.8 mm anterior (range, 7.3 mm posterior to 14.9 mm anterior) to the lateral epicondyle. The LPFL insertion on the patella was more reliably found to be about 45% (range, 23.7%-58.4%) of its lateral articular surface. The insertion on the patella was found to be in the middle third of the lateral patella. The LPFL has an origin that is variable but, on average, was found to be distal and anterior to the lateral epicondyle. The patella insertion was more reliably found to be in the middle third of the lateral patella. These anatomic relationships can help the surgeon reconstruct the LPFL in a more anatomic fashion. Surgeons who are tasked with reconstruction of the LPFL of a patient with idiopathic medial instability or a previous aggressive lateral release of the knee may reference this article to perform an anatomic

  3. An interactive, web-based tool for learning anatomic landmarks.

    PubMed

    Hallgren, Richard C; Parkhurst, Perrin E; Monson, Carol L; Crewe, Nancy M

    2002-03-01

    To evaluate the effectiveness of a Web-based interactive teaching tool that uses self-assessment exercises with real-time feedback to aid students' learning in a gross anatomy class. A total of 107 of 124 first-year medical students at one school were enrolled in the study. Students were divided into three groups: Group 1 (n = 63) received introductory material and activated their Web-based accounts; Group 2 (n = 44) received introductory material but did not activate their Web-based accounts; and Group 3 (n = 17) were not enrolled in the study and received no introductory material. Students in Group 1 had access to a graphic showing the locations of anatomic landmarks, a drill exercise, and a self-evaluation exercise. Students' ability to identify the anatomic landmarks on a 30-question midterm and a 30-question final exam were compared among the groups. The mean scores of students in Group 1 (midterm = 28.5, final = 28.1) were significantly higher than were the mean scores of students in Group 2 (midterm = 26.8, p <.001; final = 26.9, p <.017) and Group 3 (midterm = 24.8, p <.001; final = 26.4, p <.007). The Web-based tool was effective in improving students' scores on anatomic landmark exams. Future studies will determine whether the tool aids students in identifying structures located in three-dimensional space within regions such as the cranium and the abdominal cavity.

  4. Anatomical influences on internally coupled ears in reptiles.

    PubMed

    Young, Bruce A

    2016-10-01

    Many reptiles, and other vertebrates, have internally coupled ears in which a patent anatomical connection allows pressure waves generated by the displacement of one tympanic membrane to propagate (internally) through the head and, ultimately, influence the displacement of the contralateral tympanic membrane. The pattern of tympanic displacement caused by this internal coupling can give rise to novel sensory cues. The auditory mechanics of reptiles exhibit more anatomical variation than in any other vertebrate group. This variation includes structural features such as diverticula and septa, as well as coverings of the tympanic membrane. Many of these anatomical features would likely influence the functional significance of the internal coupling between the tympanic membranes. Several of the anatomical components of the reptilian internally coupled ear are under active motor control, suggesting that in some reptiles the auditory system may be more dynamic than previously recognized.

  5. Perceptions of science. The anatomical mission to Burma.

    PubMed

    Sappol, Michael

    2003-10-10

    Until the 1830s, most Americans were unfamiliar with the images of anatomy. Then a small vanguard of reformers and missionaries began to preach, at home and around the world, that an identification with the images and concepts of anatomy was a crucial part of the civilizing process. In his essay, Sappol charts the changes in the perception of self that resulted from this anatomical evangelism. Today, as anatomical images abound in the arts and the media, we still believe that anatomical images show us our inner reality.

  6. Pelvi-ureteric junction obstruction related to crossing vessels: vascular anatomic variations and implication for surgical approaches.

    PubMed

    Panthier, Frédéric; Lareyre, Fabien; Audouin, Marie; Raffort, Juliette

    2018-03-01

    Pelvi-ureteric junction obstruction corresponds to an impairment of urinary transport that can lead to renal dysfunction if not treated. Several mechanisms can cause the obstruction of the ureter including intrinsic factors or extrinsic factors such as the presence of crossing vessels. The treatment of the disease relies on surgical approaches, pyeloplasty being the standard reference. The technique consists in removing the pathologic ureteric segment and renal pelvis and transposing associated crossing vessels if present. The vascular anatomy of the pelvi-ureteric junction is complex and varies among individuals, and this can impact on the disease development and its surgical treatment. In this review, we summarize current knowledge on vascular anatomic variations in the pelvi-ureteric junction. Based on anatomic characteristics, we discuss implications for surgical approaches during pyeloplasty and vessel transposition.

  7. Corticolimbic anatomical characteristics predetermine risk for chronic pain

    PubMed Central

    Vachon-Presseau, Etienne; Tétreault, Pascal; Petre, Bogdan; Huang, Lejian; Berger, Sara E.; Torbey, Souraya; Baria, Alexis T.; Mansour, Ali R.; Hashmi, Javeria A.; Griffith, James W.; Comasco, Erika; Schnitzer, Thomas J.

    2016-01-01

    See Tracey (doi:10.1093/brain/aww147) for a scientific commentary on this article. Mechanisms of chronic pain remain poorly understood. We tracked brain properties in subacute back pain patients longitudinally for 3 years as they either recovered from or transitioned to chronic pain. Whole-brain comparisons indicated corticolimbic, but not pain-related circuitry, white matter connections predisposed patients to chronic pain. Intra-corticolimbic white matter connectivity analysis identified three segregated communities: dorsal medial prefrontal cortex–amygdala–accumbens, ventral medial prefrontal cortex–amygdala, and orbitofrontal cortex–amygdala–hippocampus. Higher incidence of white matter and functional connections within the dorsal medial prefrontal cortex–amygdala–accumbens circuit, as well as smaller amygdala volume, represented independent risk factors, together accounting for 60% of the variance for pain persistence. Opioid gene polymorphisms and negative mood contributed indirectly through corticolimbic anatomical factors, to risk for chronic pain. Our results imply that persistence of chronic pain is predetermined by corticolimbic neuroanatomical factors. PMID:27190016

  8. Uniportal anatomic combined unusual segmentectomies.

    PubMed

    González-Rivas, Diego; Lirio, Francisco; Sesma, Julio

    2017-01-01

    Nowadays, sublobar anatomic resections are gaining momentum as a valid alternative for early stage lung cancer. Despite being technically demanding, anatomic segmentectomies can be performed by uniportal video-assisted thoracic surgery (VATS) approach to combine the benefits of minimally invasiveness with the maximum lung sparing. This procedure can be even more complex if a combined resection of multiple segments from different lobes has to be done. Here we report five cases of combined and unusual segmentectomies done by the same experienced surgeon in high volume institutions to show uniportal VATS is a feasible approach for these complex resections and to share an excellent educational resource.

  9. Uniportal anatomic combined unusual segmentectomies

    PubMed Central

    Lirio, Francisco; Sesma, Julio

    2017-01-01

    Nowadays, sublobar anatomic resections are gaining momentum as a valid alternative for early stage lung cancer. Despite being technically demanding, anatomic segmentectomies can be performed by uniportal video-assisted thoracic surgery (VATS) approach to combine the benefits of minimally invasiveness with the maximum lung sparing. This procedure can be even more complex if a combined resection of multiple segments from different lobes has to be done. Here we report five cases of combined and unusual segmentectomies done by the same experienced surgeon in high volume institutions to show uniportal VATS is a feasible approach for these complex resections and to share an excellent educational resource. PMID:29078653

  10. Anatomically accurate individual face modeling.

    PubMed

    Zhang, Yu; Prakash, Edmond C; Sung, Eric

    2003-01-01

    This paper presents a new 3D face model of a specific person constructed from the anatomical perspective. By exploiting the laser range data, a 3D facial mesh precisely representing the skin geometry is reconstructed. Based on the geometric facial mesh, we develop a deformable multi-layer skin model. It takes into account the nonlinear stress-strain relationship and dynamically simulates the non-homogenous behavior of the real skin. The face model also incorporates a set of anatomically-motivated facial muscle actuators and underlying skull structure. Lagrangian mechanics governs the facial motion dynamics, dictating the dynamic deformation of facial skin in response to the muscle contraction.

  11. Anatomical and Functional Results of Lamellar Macular Holes Surgery.

    PubMed

    Papadopoulou, D; Donati, G; Mangioris, G; Pournaras, C J

    2016-04-01

    To determine the long-term surgical findings and outcomes after vitrectomy for symptomatic lamellar macular holes. We studied 28 patients with lamellar macular holes and central visual loss or distortion. All interventions were standard 25 G vitrectomy with membranectomy of the internal limiting membrane (ILM), peeling and gas tamponade with SF6 20 %. Operations were performed by a single experienced surgeon within the last 3 years. Best corrected visual acuity and optical coherence tomography appearance were determined preoperatively and postoperatively. Following the surgical procedure, all macular holes were closed; however, in 3 eyes, significant foveal thinning was associated with changes in the retinal pigment epithelium changes. The mean best-corrected visual acuity improved postoperatively in the majority of the patients (n: 21, mean 0.3 logMAR), stabilised in 4 patients and decreased in 3 patients (mean 0.4 logMAR). Spectral Domain-Optical coherence tomography (SD-OCT) showed resolution of the lamellar lesion and improved macular contour in all cases. We demonstrated improvement in postoperative vision and the anatomical reconstruction of the anatomical contour of the fovea in most eyes with symptomatic lamellar holes. These findings indicate that vitrectomy, membranectomy and ILM peeling with gas tamponade is a beneficial treatment of symptomatic lamellar macular holes. Georg Thieme Verlag KG Stuttgart · New York.

  12. Mistakes in the usage of anatomical terminology in clinical practice.

    PubMed

    Kachlik, David; Bozdechova, Ivana; Cech, Pavel; Musil, Vladimir; Baca, Vaclav

    2009-06-01

    Anatomical terminology serves as a basic communication tool in all the medical fields. Therefore Latin anatomical nomenclature has been repetitively issued and revised from 1895 (Basiliensia Nomina Anatomica) until 1998, when the last version was approved and published as the Terminologia Anatomica (International Anatomical Terminology) by the Federative Committee on Anatomical Terminology. A brief history of the terminology and nomenclature development is mentioned, along with the concept and contributions of the Terminologia Anatomica including the employed abbreviations. Examples of obsolete anatomical terms and their current synonyms are listed. Clinicians entered the process of the nomenclature revision and this aspect is demonstrated with several examples of terms used in clinical fields only, some already incorporated in the Terminologia Anatomica and a few obsolete terms still alive in non-theoretical communication. Frequent mistakes in grammar and orthography are stated as well. Authors of the article strongly recommend the use of the recent revision of the Latin anatomical nomenclature both in theoretical and clinical medicine.

  13. Network of anatomical texts (NAnaTex), an open-source project for visualizing the interaction between anatomical terms.

    PubMed

    Momota, Ryusuke; Ohtsuka, Aiji

    2018-01-01

    Anatomy is the science and art of understanding the structure of the body and its components in relation to the functions of the whole-body system. Medicine is based on a deep understanding of anatomy, but quite a few introductory-level learners are overwhelmed by the sheer amount of anatomical terminology that must be understood, so they regard anatomy as a dull and dense subject. To help them learn anatomical terms in a more contextual way, we started a new open-source project, the Network of Anatomical Texts (NAnaTex), which visualizes relationships of body components by integrating text-based anatomical information using Cytoscape, a network visualization software platform. Here, we present a network of bones and muscles produced from literature descriptions. As this network is primarily text-based and does not require any programming knowledge, it is easy to implement new functions or provide extra information by making changes to the original text files. To facilitate collaborations, we deposited the source code files for the network into the GitHub repository ( https://github.com/ryusukemomota/nanatex ) so that anybody can participate in the evolution of the network and use it for their own non-profit purposes. This project should help not only introductory-level learners but also professional medical practitioners, who could use it as a quick reference.

  14. Anatomical Regional Targeted (ART) BOTOX Injection Technique: A Novel Paradigm for Migraines and Chronic Headaches

    PubMed Central

    Sanniec, Kyle; Pezeshk, Ronnie; Chung, Michael

    2016-01-01

    Summary: Migraine headaches are a debilitating disease that causes significant socioeconomic problems. One of the speculated etiologies of the generation of migraines is peripheral nerve irritation at different trigger points. The use of Onabotulinum toxin A (BOTOX), although initially a novel approach, has now been determined to be a valid treatment for chronic headaches and migraines as described in the Phase III Research Evaluating Migraine Prophylaxis Therapy trials that prompted the approval by the Food and Drug Administration for treatment of chronic migraines. The injection paradigm established by this trial was one of a broad injection pattern across large muscle groups that did not always correspond to the anatomical locations of nerves. The senior author developed the Anatomical Regional Targeted BOTOX injection paradigm as an alternative to the current injection model. This technique targets both the anatomical location of nerves known to have causal effects with migraines and the region where the pain localizes, to provide relief across a wide distribution of the peripheral nerve. This article serves as a guide to the Anatomical Regional Targeted injection technique, which, to our knowledge, is the first comprehensive BOTOX injection paradigm described in the literature for treatment of migraines that targets nerves and nerve areas rather than purely muscle groups. This technique is based on the most up-to-date anatomical and scientific studies and large-volume migraine surgery experience. PMID:28293532

  15. Anatomic features involved in technical complexity of partial nephrectomy.

    PubMed

    Hou, Weibin; Yan, Weigang; Ji, Zhigang

    2015-01-01

    Nephrometry score systems, including RENAL nephrometry, preoperative aspects and dimensions used for an anatomical classification system, C-index, diameter-axial-polar nephrometry, contact surface area score, calculating resected and ischemized volume, renal tumor invasion index, surgical approach renal ranking score, zonal NePhRO score, and renal pelvic score, have been reviewed. Moreover, salient anatomic features like the perinephric fat and vascular variants also have been discussed. We then extract 7 anatomic characteristics, namely tumor size, spatial location, adjacency, exophytic/endophytic extension, vascular variants, pelvic anatomy, and perinephric fat as important features for partial nephrectomy. For novice surgeons, comprehensive and adequate anatomic consideration may help them in their early clinical practice. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Anatomically-Aided PET Reconstruction Using the Kernel Method

    PubMed Central

    Hutchcroft, Will; Wang, Guobao; Chen, Kevin T.; Catana, Ciprian; Qi, Jinyi

    2016-01-01

    This paper extends the kernel method that was proposed previously for dynamic PET reconstruction, to incorporate anatomical side information into the PET reconstruction model. In contrast to existing methods that incorporate anatomical information using a penalized likelihood framework, the proposed method incorporates this information in the simpler maximum likelihood (ML) formulation and is amenable to ordered subsets. The new method also does not require any segmentation of the anatomical image to obtain edge information. We compare the kernel method with the Bowsher method for anatomically-aided PET image reconstruction through a simulated data set. Computer simulations demonstrate that the kernel method offers advantages over the Bowsher method in region of interest (ROI) quantification. Additionally the kernel method is applied to a 3D patient data set. The kernel method results in reduced noise at a matched contrast level compared with the conventional ML expectation maximization (EM) algorithm. PMID:27541810

  17. Anatomically-aided PET reconstruction using the kernel method.

    PubMed

    Hutchcroft, Will; Wang, Guobao; Chen, Kevin T; Catana, Ciprian; Qi, Jinyi

    2016-09-21

    This paper extends the kernel method that was proposed previously for dynamic PET reconstruction, to incorporate anatomical side information into the PET reconstruction model. In contrast to existing methods that incorporate anatomical information using a penalized likelihood framework, the proposed method incorporates this information in the simpler maximum likelihood (ML) formulation and is amenable to ordered subsets. The new method also does not require any segmentation of the anatomical image to obtain edge information. We compare the kernel method with the Bowsher method for anatomically-aided PET image reconstruction through a simulated data set. Computer simulations demonstrate that the kernel method offers advantages over the Bowsher method in region of interest quantification. Additionally the kernel method is applied to a 3D patient data set. The kernel method results in reduced noise at a matched contrast level compared with the conventional ML expectation maximization algorithm.

  18. Anatomically-aided PET reconstruction using the kernel method

    NASA Astrophysics Data System (ADS)

    Hutchcroft, Will; Wang, Guobao; Chen, Kevin T.; Catana, Ciprian; Qi, Jinyi

    2016-09-01

    This paper extends the kernel method that was proposed previously for dynamic PET reconstruction, to incorporate anatomical side information into the PET reconstruction model. In contrast to existing methods that incorporate anatomical information using a penalized likelihood framework, the proposed method incorporates this information in the simpler maximum likelihood (ML) formulation and is amenable to ordered subsets. The new method also does not require any segmentation of the anatomical image to obtain edge information. We compare the kernel method with the Bowsher method for anatomically-aided PET image reconstruction through a simulated data set. Computer simulations demonstrate that the kernel method offers advantages over the Bowsher method in region of interest quantification. Additionally the kernel method is applied to a 3D patient data set. The kernel method results in reduced noise at a matched contrast level compared with the conventional ML expectation maximization algorithm.

  19. Gender differences of airway dimensions in anatomically matched sites on CT in smokers.

    PubMed

    Kim, Yu-Il; Schroeder, Joyce; Lynch, David; Newell, John; Make, Barry; Friedlander, Adam; Estépar, Raúl San José; Hanania, Nicola A; Washko, George; Murphy, James R; Wilson, Carla; Hokanson, John E; Zach, Jordan; Butterfield, Kiel; Bowler, Russell P; Copdgene Investigators

    2011-08-01

    There are limited data on, and controversies regarding gender differences in the airway dimensions of smokers. Multi-detector CT (MDCT) images were analyzed to examine whether gender could explain differences in airway dimensions of anatomically matched airways in smokers. We used VIDA imaging software to analyze MDCT scans from 2047 smokers (M:F, 1021:1026) from the COPDGene® cohort. The airway dimensions were analyzed from segmental to subsubsegmental bronchi. We compared the differences of luminal area, inner diameter, wall thickness, wall area percentage (WA%) for each airway between men and women, and multiple linear regression including covariates (age, gender, body sizes, and other relevant confounding factors) was used to determine the predictors of each airway dimensions. Lumen area, internal diameter and wall thickness were smaller for women than men in all measured airway (18.4 vs 22.5 mm(2) for segmental bronchial lumen area, 10.4 vs 12.5 mm(2) for subsegmental bronchi, 6.5 vs 7.7 mm(2) for subsubsegmental bronchi, respectively p < 0.001). However, women had greater WA% in subsegmental and subsubsegmental bronchi. In multivariate regression, gender remained one of the most significant predictors of WA%, lumen area, inner diameter and wall thickness. Women smokers have higher WA%, but lower luminal area, internal diameter and airway thickness in anatomically matched airways as measured by CT scan than do male smokers. This difference may explain, in part, gender differences in the prevalence of COPD and airflow limitation.

  20. Safe Corridor to Access Clivus for Endoscopic Trans-Sphenoidal Surgery: A Radiological and Anatomical Study

    PubMed Central

    Cheng, Ye; Zhang, Siwen; Chen, Yong; Zhao, Gang

    2015-01-01

    Purpose Penetration of the clivus is required for surgical access of the brain stem. The endoscopic transclivus approach is a difficult procedure with high risk of injury to important neurovascular structures. We undertook a novel anatomical and radiological investigation to understand the structure of the clivus and neurovascular structures relevant to the extended trans-nasal trans-sphenoid procedure and determine a safe corridor for the penetration of the clivus. Method We examined the clivus region in the computed tomographic angiography (CTA) images of 220 adults, magnetic resonance (MR) images of 50 adults, and dry skull specimens of 10 adults. Multiplanar reconstruction (MPR) of the CT images was performed, and the anatomical features of the clivus were studied in the coronal, sagittal, and axial planes. The data from the images were used to determine the anatomical parameters of the clivus and neurovascular structures, such as the internal carotid artery and inferior petrosal sinus. Results The examination of the CTA and MR images of the enrolled subjects revealed that the thickness of the clivus helped determine the depth of the penetration, while the distance from the sagittal midline to the important neurovascular structures determined the width of the penetration. Further, data from the CTA and MR images were consistent with those retrieved from the examination of the cadaveric specimens. Conclusion Our findings provided certain pointers that may be useful in guiding the surgery such that inadvertent injury to vital structures is avoided and also provided supportive information for the choice of the appropriate endoscopic equipment. PMID:26368821

  1. Clavicle anatomical osteosynthesis plate breakage - failure analysis report based on patient morphological parameters.

    PubMed

    Marinescu, Rodica; Antoniac, Vasile Iulian; Stoia, Dan Ioan; Lăptoiu, Dan Constantin

    2017-01-01

    Clavicle fracture reported incidence is about 5% of fractures in adult; among them, those located in the middle third of the shaft represent more than 80% from the total of cases. Due to the special morphological and biomechanical constraints of the clavicle, several methods for restoring morphological integrity in these fractures are described, including conservative, non-surgical treatment. The last 10 years of clinical studies in the field have favored the surgical treatment for selected cases; several osteosynthesis implants are in use - mostly anatomical plates with specific advantages and documented complications. A failed anatomical clavicle plate was explanted and analyzed after a protocol using stereomicroscopy, scanning electron microscopy and energy dispersive spectrometry. Based on the computed tomography (CT) scan determination of patient morphological parameters, a finite elements analysis of the failure scenario was completed. The failure analysis has proved that the plate breakage had occurred in the point of maximal elastic stress and minor deformation. The clinical implication is that no hole should remain free of screw during clavicle plate fixation and the implant should be chosen based on patient morphological parameters. In comminuted clavicle fracture, anatomic bridging with locked plate technique may lead to implant failure due to increase of the stress in the midshaft area. Thorough knowledge of anatomy and morphology of complex bones like the clavicle is necessary. Modern osteosynthesis anatomical implants are still to be improved.

  2. Anatomical and procedural determinants of ambulatory blood pressure lowering following catheter-based renal denervation using radiofrequency.

    PubMed

    Lauder, Lucas; Ewen, Sebastian; Tzafriri, Abraham R; Edelman, Elazer R; Cremers, Bodo; Kulenthiran, Saarraaken; Ukena, Christian; Linz, Dominik; Kindermann, Ingrid; Tsioufis, Costas; Scheller, Bruno; Böhm, Michael; Mahfoud, Felix

    2018-03-02

    Catheter-based renal sympathetic denervation (RDN) has been introduced to lower blood pressure (BP) and sympathetic activity in patients with uncontrolled hypertension with at best equivocal results. It has been postulated that anatomic and procedural elements introduce unaccounted variability and yet little is known of the impact of renal anatomy and procedural parameters on BP response to RDN. Anatomical parameters such as length and diameter were analyzed by quantitative vascular analysis and the prevalence of accessory renal arteries and renal artery disease were documented in 150 patients with resistant hypertension undergoing bilateral RDN using a mono-electrode radiofrequency catheter (Symplicity Flex, Medtronic). Accessory renal arteries and renal artery disease were present in 56 (37%) and 14 patients (9%), respectively. At 6-months, 24 h-ambulatory BP was reduced by 11/6 mm Hg (p < 0.001 for both). Change of systolic blood pressure (SBP) was not related to the presence of accessory renal arteries (p = 0.543) or renal artery disease (p = 0.598). Patients with at least one main renal artery diameter ≤ 4 mm had a more pronounced reduction of 24 h-ambulatory SBP compared to patients where both arteries were >4 mm (-19 vs. -10 mmHg; p = 0.038). Neither the length of the renal artery nor the number of RF ablations influenced 24 h-ambulatory BP reduction at 6 months. 24 h-ambulatory BP lowering was most pronounced in patients with smaller renal artery diameter but not related to renal artery length, accessory arteries or renal artery disease. Further, there was no dose-response relationship observed with increasing number of ablations. Because little is known of the impact of renal anatomy and procedural parameters on blood pressure (BP) response to renal denervation (RDN), anatomical and procedural data were analyzed in 150 patients undergoing bilateral RDN. BP lowering was most pronounced in patients with smaller renal

  3. The "G-Spot" Is Not a Structure Evident on Macroscopic Anatomic Dissection of the Vaginal Wall.

    PubMed

    Hoag, Nathan; Keast, Janet R; O'Connell, Helen E

    2017-12-01

    Controversy exists in the literature regarding the presence or absence of an anatomic "G-spot." However, few studies have examined the detailed topographic or histologic anatomy of the putative G-spot location. To determine the anatomy of the anterior vaginal wall and present detailed, systematic, accessible findings from female cadaveric dissections to provide anatomic clarity with respect to this location. Systematic anatomic dissections were performed on 13 female cadavers (32-97 years old, 8 fixed and 5 fresh) to characterize the gross anatomy of the anterior vaginal wall. Digital photography was used to document dissections. Dissection preserved the anterior vaginal wall, urethra, and clitoris. In 9 cadavers, the vaginal epithelial layer was reflected to expose the underlying urethral wall and associated tissues. In 4 cadavers, the vaginal wall was left intact before preservation. Once photographed, 8 specimens were transversely sectioned for macroscopic inspection and histologic examination. The presence or absence of a macroscopic anatomic structure at detailed cadaveric pelvis dissection that corresponds to the previously described G-spot and gross anatomic description of the anterior vaginal wall. Deep to the lining epithelium of the anterior vaginal wall is the urethra. There is no macroscopic structure other than the urethra and vaginal wall lining in the location of the putative G-spot. Specifically, there is no apparent erectile or "spongy" tissue in the anterior vaginal wall, except where the urethra abuts the clitoris distally. The absence of an anatomic structure corresponding to the putative G-spot helps clarify the controversy on this subject. Limitations to this study include limited access to specimens immediately after death and potential for observational bias. In addition, age, medical history, and cause of death are not publishable for privacy reasons. However, it is one of the most thorough and complete anatomic evaluations documenting the

  4. An anatomical review of spinal cord blood supply.

    PubMed

    Melissano, G; Bertoglio, L; Rinaldi, E; Leopardi, M; Chiesa, R

    2015-10-01

    Knowledge of the spinal cord (SC) vascular supply is important in patients undergoing procedures that involve the thoracic and thoracoabdominal aorta. However, the SC vasculature has a complex anatomy, and teaching is often based only on anatomical sketches with highly variable accuracy; historically, this has required a "leap of faith" on the part of aortic surgeons. Fortunately, this "leap of faith" is no longer necessary given recent breakthroughs in imaging technologies and postprocessing software. Imaging methods have expanded the non-invasive diagnostic ability to determine a patient's SC vascular pattern, particularly in detecting the presence and location of the artery of Adamkiewicz. CT is the imaging modality of choice for most patients with thoracic and thoracoabdominal aortic disease, proving especially useful in the determination of feasibility and planning of endovascular treatment. Thus the data set required for analysis of SC vascular anatomy is usually already available. We have concentrated our efforts on CT angiography, which offers particularly good imaging capabilities with state-of-the-art multidetector scanners. Multidetector row helical CT provides examinations of an extensive range in the craniocaudal direction with thin collimation in a short time interval, giving excellent temporal and spatial resolution. This paper provides examples of the SC vasculature imaging quality that can be obtained with 64 row scanners and appropriate postprocessing. Knowledge of the principal anatomical features of the SC blood supply of individual patients undergoing open or endovascular thoracoabdominal procedures has several potential benefits. For open surgery, analysis of the SC vasculature could tell us the aortic region that feeds the Adamkiewicz artery and thus needs to be reimplanted. For endovascular procedures, we can determine whether the stent-graft will cover the Adamkiewicz artery, thus avoiding unnecessary coverage. CT data can also be used to

  5. Anatomical terminology and nomenclature: past, present and highlights.

    PubMed

    Kachlik, David; Baca, Vaclav; Bozdechova, Ivana; Cech, Pavel; Musil, Vladimir

    2008-08-01

    The anatomical terminology is a base for medical communication. It is elaborated into a nomenclature in Latin. Its history goes back to 1895, when the first Latin anatomical nomenclature was published as Basiliensia Nomina Anatomica. It was followed by seven revisions (Jenaiensia Nomina Anatomica 1935, Parisiensia Nomina Anatomica 1955, Nomina Anatomica 2nd to 6th edition 1960-1989). The last revision, Terminologia Anatomica, (TA) created by the Federative Committee on Anatomical Terminology and approved by the International Federation of Associations of Anatomists, was published in 1998. Apart from the official Latin anatomical terminology, it includes a list of recommended English equivalents. In this article, major changes and pitfalls of the nomenclature are discussed, as well as the clinical anatomy terms. The last revision (TA) is highly recommended to the attention of not only teachers, students and researchers, but also to clinicians, doctors, translators, editors and publishers to be followed in their activities.

  6. Extra-Anatomic Revascularization of Extensive Coral Reef Aorta.

    PubMed

    Gaggiano, Andrea; Kasemi, Holta; Monti, Andrea; Laurito, Antonella; Maselli, Mauro; Manzo, Paola; Quaglino, Simone; Tavolini, Valeria

    2017-10-01

    Coral reef aorta (CRA) is a rare, potential lethal disease of the visceral aorta as it can cause visceral and renal infarction. Various surgical approaches have been proposed for the CRA treatment. The purpose of this article is to report different extensive extra-anatomic CRA treatment modalities tailored on the patients' clinical and anatomic presentation. From April 2006 to October 2012, 4 symptomatic patients with extensive CRA were treated at our department. Extra-anatomic aortic revascularization with selective visceral vessels clamping was performed in all cases. Technical success was 100%. No perioperative death was registered. All patients remained asymptomatic during the follow-up period (62, 49, 25, and 94 months, respectively), with bypasses and target vessels patency. The extra-anatomic bypass with selective visceral vessels clamping reduces the aortic occlusion time and the risk of organ ischemia. All approaches available should be considered on a case-by-case basis and in high-volume centers. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Anatomical and morphological study of the subcoracoacromial canal.

    PubMed

    Le Reun, O; Lebhar, J; Mateos, F; Voisin, J L; Thomazeau, H; Ropars, M

    2016-12-01

    Many clinical anatomy studies have looked into how variations in the acromion, coracoacromial ligament (CAL) and subacromial space are associated with rotator cuff injuries. However, no study up to now had defined anatomically the fibro-osseous canal that confines the supraspinatus muscle in the subcoracoacromial space. Through an anatomical study of the scapula, we defined the bone-related parameters of this canal and its anatomical variations. This study on dry bones involved 71 scapulas. With standardised photographs in two orthogonal views (superior and lateral), the surface area of the subcoracoacromial canal and the anatomical parameters making up this canal were defined and measured using image analysis software. The primary analysis evaluated the anatomical parameters of the canal as a function of three canal surface area groups; the secondary analysis looked into how variations in the canal surface area were related to the type of acromion according to the Bigliani classification. Relative to glenoid width, the group with a large canal surface area (L) had significantly less lateral overhang of the acromion than the group with a small canal surface area (S), with ratios of 0.41±0.23 and 0.58±0.3, respectively (P=0.04). The mean length of the CAL was 46±8mm in the L group and 39±9mm in the S group (P=0.003). The coracoacromial arch angle was 38°±11° in the L group and 34°±9° in the S group; the canal surface area was smaller in specimens with a smaller coracoacromial arch angle (P=0.20). Apart from acromial morphology, there could be innate anatomical features of the scapula that predispose people to extrinsic lesions to the supraspinatus tendon (lateral overhang, coracoacromial arch angle) by reducing the subcoracoacromial canal's surface area. Anatomical descriptive study. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  8. Association between CFH, CFB, ARMS2, SERPINF1, VEGFR1 and VEGF polymorphisms and anatomical and functional response to ranibizumab treatment in neovascular age-related macular degeneration.

    PubMed

    Cobos, Estefania; Recalde, Sergio; Anter, Jaouad; Hernandez-Sanchez, Maria; Barreales, Carla; Olavarrieta, Leticia; Valverde, Alicia; Suarez-Figueroa, Marta; Cruz, Fernando; Abraldes, Maximino; Pérez-Pérez, Julian; Fernández-Robredo, Patricia; Arias, Luis; García-Layana, Alfredo

    2018-03-01

    We sought to determine if specific genetic single nucleotide polymorphisms (SNPs) influence vascular endothelial growth factor inhibition response to ranibizumab in neovascular age-related macular degeneration (AMD). A total of 403 Caucasian patients diagnosed with exudative AMD were included. After a three-injection loading phase, a pro re nata regimen was followed. Nine SNPs from six different genes (CFH, CFB, ARMS2, SERPINF1, VEGFR1, VEGF) were genotyped. Non-genetic risk factors (gender, smoking habit and hypertension) were also assessed. Patients were classified as good or poor responders (GR or PR) according to functional (visual acuity), anatomical (foveal thickness measured by OCT) and fluid criteria (fluid/no fluid measured by OCT). Hypertension was the environmental factor with the strongest poor response association with ranibizumab in the anatomical measure after the loading phase (p = 0.0004; OR 3.7; 95% CI, 2.4-5.8) and after 12 months of treatment (p = 10 -5 ; OR 2.3; 95% CI, 1.5-3.4). The genetic variants rs12614 (CFB), rs699947 (VEGFA) and rs7993418 (VEGFR1) predisposed patients to a good response, while rs12603486 and rs1136287 (SERPINF1) were associated with a poor response. The protective genotype of rs800292 variant (CFH) was also associated with a poor anatomical response (p 0.0048). All these data suggest that genetics play an important role in treatment response in AMD patients. © 2017 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  9. Using Horn's Parallel Analysis Method in Exploratory Factor Analysis for Determining the Number of Factors

    ERIC Educational Resources Information Center

    Çokluk, Ömay; Koçak, Duygu

    2016-01-01

    In this study, the number of factors obtained from parallel analysis, a method used for determining the number of factors in exploratory factor analysis, was compared to that of the factors obtained from eigenvalue and scree plot--two traditional methods for determining the number of factors--in terms of consistency. Parallel analysis is based on…

  10. Inexpensive anatomical trainer for bronchoscopy.

    PubMed

    Di Domenico, Stefano; Simonassi, Claudio; Chessa, Leonardo

    2007-08-01

    Flexible fiberoptic bronchoscopy is an indispensable tool for optimal management of intensive care unit patients. However, the acquisition of sufficient training in bronchoscopy is not straightforward during residency, because of technical and ethical problems. Moreover, the use of commercial simulators is limited by their high cost. In order to overcome these limitations, we realized a low-cost anatomical simulator to acquire and maintain the basic skill to perform bronchoscopy in ventilated patients. We used 1.5 mm diameter iron wire to construct the bronchial tree scaffold; glazier-putty was applied to create the anatomical model. The model was covered by several layers of newspaper strips previously immersed in water and vinilic glue. When the model completely dried up, it was detached from the scaffold by cutting it into six pieces, it was reassembled, painted and fitted with an endotracheal tube. We used very cheap material and the final cost was euro16. The trainer resulted in real-scale and anatomically accurate, with appropriate correspondence on endoscopic view between model and patients. All bronchial segments can be explored and easily identified by endoscopic and external vision. This cheap simulator is a valuable tool for practicing, particularly in a hospital with limited resources for medical training.

  11. [Cor triatriatum. Anatomical forms and surgical treatment of 6 consecutive cases].

    PubMed

    Bloch, G; Heurtematte, Y; Menu, P; Mesnildrey, P; Casasoprana, A; Magnier, S; Tamari, W; Seurat, M C; Aubry, P; Vernant, P

    1988-01-01

    Six cases of cor triatriatum documented and operated on at Henri-Mondor hospital between 1980 and 1984 are reported. Ages at the time of surgery ranged from 8 months to 57 years. Four of the 6 patients presented with pulmonary hypertension. Anatomic types consisted of 4 diaphragmatic types and 2 more complex malformations. Associated lesions were present in all but one patients. They consisted mostly of interatrial defects (depending on their position with regard to the intra-atrial membrane, they play a determinant role in the symptomatology) and of a left superior vena cava (which might play a role in the embryogenesis of the malformation). Except for one early postoperative death, results of surgery were excellent for all patients, with a mean follow-up of 5 years. This series, compared with the literature, allows precising the embryologic and anatomic aspects of the malformation and the surgical techniques in complex types.

  12. Reflective journals: unmasking student perceptions of anatomical education.

    PubMed

    Lazarus, L; Sookrajh, R; Satyapal, K S

    2017-01-01

    In medical education, reflection has been considered to be a core skill in professional competence. The anatomy laboratory is an ideal setting for faculty/ student interaction and provides invaluable opportunities for active learning and reflection on anatomical knowledge. This study was designed to record student attitudes regarding human cadaveric dissection, explore their experiences of anatomy through an analysis of their journal-reflective writings and determine whether this type of creative writing had a beneficial effect on those students who chose to complete them. A total of 75 journals from Medical and Allied Health Science students were collected and analysed. Results were categorised according to the following themes: (i) Dissecting room stressors (27.6%); (ii) Educational value of dissection (26.3%); (iii) Appreciation, Gratitude, Respect and Curiosity for the cadaver (18.9%); (iv) Positive and negative sentiments expressed in the dissecting room (25.8%); (v) Benefit of alternate teaching modalities (4.6%); (vi) Spirituality/Religious Beliefs (3.7%); (vii) Shared humanity and emotional bonds (3.69%); (viii) Acknowledgement of human anatomical variations (3.2%); (ix) Beauty and complexity of the human body (1.8%) and (x) Psychological detachment (0.9%). Students appreciated the opportunity to share their emotions and reflect on the humanistic dimension of anatomy as a subject. Student reflections illustrated clearly their thoughts and some of the difficult issues with which they wrestled. The anatomy laboratory is seen as the budding clinician's first encounter with a patient, albeit a cadaver. This was the first time that reflective journals were given to students in the discipline. Reflective journals allow students to express themselves in an open-ended and creative fashion. It also assists students to integrate anatomy and clinical medicine and assists in applying their basic anatomical knowledge in an authentic, yet safe environment.

  13. Tobacco use predicts a more difficult episode of care after anatomic total shoulder arthroplasty.

    PubMed

    Wells, Daniel B; Holt, Andrew M; Smith, Richard A; Brolin, Tyler J; Azar, Frederick M; Throckmorton, Thomas W

    2018-01-01

    In the current health care environment, it is becoming increasingly important to recognize risks factors that may affect a patient's postoperative outcome. To determine the potential impact of tobacco as a risk factor, we evaluated postoperative pain, narcotic use, length of stay, reoperations, and complications in the global 90-day episode of care for patients undergoing anatomic total shoulder arthroplasty (TSA) who were current tobacco users, former users, or nonusers. Database search identified 163 patients with primary anatomic TSA done for glenohumeral arthritis; these were divided into 3 groups: current tobacco users (28), nonusers (88), and former users (47). All surgeries were done with the same technique and implants. Patients in the current tobacco use group had significantly higher visual analog scale scores preoperatively and at 12 weeks postoperatively than nonusers and former users. Mean improvement in visual analog scale scores was significantly less in current tobacco users. Cumulative oral morphine equivalent use at 12 weeks was significantly higher in current tobacco users than in nonusers and former users. The average oral morphine equivalent per day was also significantly higher in the current tobacco users than in nonusers and former users. There were no significant differences in length of stay or complications. Although length of stay, complication rates, hospital readmissions, and reoperation rates were not significantly different, tobacco users reported increased postoperative pain and narcotic use in the global period after TSA. Former tobacco users were found to have a postoperative course similar to that of nonusers, suggesting that discontinuation of tobacco use can improve a patient's episode of care performance after TSA. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  14. [Sigismund Laskowski and his anatomical preparations technique].

    PubMed

    Gryglewski, Ryszard W

    2015-01-01

    Fixation of the entire bodies or individual organs, and later as well tissues and cellular structures, was and still is often a challenge for anatomists and histologists. Technique that combines extensive knowledge of natural sciences, as well as technical skills, was by those best researchers as Frederik Ruysch, brought to perfection. Preparations, if done with care and talent, are really propelling progress in anatomical studies and determining the quality of education for medical students and young physicians. And as it is true for many of today's medical disciplines and natural sciences, the nineteenth century was in many ways a breaking point for preparatory techniques in the realm of anatomy and histology. Among those who have achieved success, earning notoriety during their lifetime and often going into the annals of European most distinguished scholars were some Polish names: Louis Maurice Hirschfeld, whose preparations of the nervous system earned him well-deserved, international fame, Louis Charles Teichmann, who was the very first so precisely describing the lymphatic system and a creator of unique injection mass, Henry Kadyi, known for his outstanding preparations, especially of vascular system. Henry Frederick Hoyer sen., who was one of the first to use formalin regularly for accurate microscopic preparations, is seen by many as the founder of the Polish histology. In this group of innovators and precursors of modern preparation techniques place should be reserved for Zygmunt (Sigismund) Laskowski, Polish patriot, fighting in January Uprising, later an immigrant, a professor at the university sequentially Paris and Geneva. Acclaimed author of anatomical tables and certainly creator of one of the groundbreaking techniques in anatomical preparations. Based after many years of research on the simple glycerine-phenol mixture achieved excellent results both in fixation of entire bodies and organs or tissues. Quality of those preparations was as high and

  15. Anatomical entity mention recognition at literature scale

    PubMed Central

    Pyysalo, Sampo; Ananiadou, Sophia

    2014-01-01

    Motivation: Anatomical entities ranging from subcellular structures to organ systems are central to biomedical science, and mentions of these entities are essential to understanding the scientific literature. Despite extensive efforts to automatically analyze various aspects of biomedical text, there have been only few studies focusing on anatomical entities, and no dedicated methods for learning to automatically recognize anatomical entity mentions in free-form text have been introduced. Results: We present AnatomyTagger, a machine learning-based system for anatomical entity mention recognition. The system incorporates a broad array of approaches proposed to benefit tagging, including the use of Unified Medical Language System (UMLS)- and Open Biomedical Ontologies (OBO)-based lexical resources, word representations induced from unlabeled text, statistical truecasing and non-local features. We train and evaluate the system on a newly introduced corpus that substantially extends on previously available resources, and apply the resulting tagger to automatically annotate the entire open access scientific domain literature. The resulting analyses have been applied to extend services provided by the Europe PubMed Central literature database. Availability and implementation: All tools and resources introduced in this work are available from http://nactem.ac.uk/anatomytagger. Contact: sophia.ananiadou@manchester.ac.uk Supplementary Information: Supplementary data are available at Bioinformatics online. PMID:24162468

  16. [Project HRANAFINA--Croatian anatomical and physiological terminology].

    PubMed

    Vodanović, Marin

    2012-01-01

    HRANAFINA--Croatian Anatomical and Physiological Terminology is a project of the University of Zagreb School of Dental Medicine funded by the Croatian Science Foundation. It is performed in cooperation with other Croatian universities with medical schools. This project has a two-pronged aim: firstly, building of Croatian anatomical and physiological terminology and secondly, Croatian anatomical and physiological terminology usage popularization between health professionals, medical students, scientists and translators. Internationally recognized experts from Croatian universities with medical faculties and linguistics experts are involved in the project. All project activities are coordinated in agreement with the National Coordinator for Development of Croatian Professional Terminology. The project enhances Croatian professional terminology and Croatian language in general, increases competitiveness of Croatian scientists on international level and facilitates the involvement of Croatian scientists, health care providers and medical students in European projects.

  17. Aortic anatomic severity grade correlates with resource utilization.

    PubMed

    Rasheed, Khurram; Cullen, John P; Seaman, Matthew J; Messing, Susan; Ellis, Jennifer L; Glocker, Roan J; Doyle, Adam J; Stoner, Michael C

    2016-03-01

    total cost and need for adjunctive procedures during EVAR. Preoperative assessment with ASG scores can delineate patients at greater risk for increased resource use. Patient comorbid factors are associated with anatomic complexity defined according to ASG. A critical examination of the relationship between anatomic complexity and finances is required within the context of aggressive endovascular treatment strategies and shifts toward value-based reimbursement. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  18. Anatomical Entity Recognition with a Hierarchical Framework Augmented by External Resources

    PubMed Central

    Xu, Yan; Hua, Ji; Ni, Zhaoheng; Chen, Qinlang; Fan, Yubo; Ananiadou, Sophia; Chang, Eric I-Chao; Tsujii, Junichi

    2014-01-01

    References to anatomical entities in medical records consist not only of explicit references to anatomical locations, but also other diverse types of expressions, such as specific diseases, clinical tests, clinical treatments, which constitute implicit references to anatomical entities. In order to identify these implicit anatomical entities, we propose a hierarchical framework, in which two layers of named entity recognizers (NERs) work in a cooperative manner. Each of the NERs is implemented using the Conditional Random Fields (CRF) model, which use a range of external resources to generate features. We constructed a dictionary of anatomical entity expressions by exploiting four existing resources, i.e., UMLS, MeSH, RadLex and BodyPart3D, and supplemented information from two external knowledge bases, i.e., Wikipedia and WordNet, to improve inference of anatomical entities from implicit expressions. Experiments conducted on 300 discharge summaries showed a micro-averaged performance of 0.8509 Precision, 0.7796 Recall and 0.8137 F1 for explicit anatomical entity recognition, and 0.8695 Precision, 0.6893 Recall and 0.7690 F1 for implicit anatomical entity recognition. The use of the hierarchical framework, which combines the recognition of named entities of various types (diseases, clinical tests, treatments) with information embedded in external knowledge bases, resulted in a 5.08% increment in F1. The resources constructed for this research will be made publicly available. PMID:25343498

  19. Comparison of Pap smear quality with anatomical spatula and convenience (spatula-cytobrush) methods: a single blind clinical trial.

    PubMed

    Abdali, Khadijeh; Soleimani, Marzieh; Khajehei, Marjan; Tabatabaee, Hamid Reza; Komar, Perikala V; Montazer, Nader Riaz

    2010-01-01

    The Papanicolaou smear is a standard test for cervical cancer screening; however, the most important challenge is high false negative results. Several factors contribute to this problem and one the most important is inappropriate sampling. The aim of this study was to compare the quality of smears obtained by either an anatomical spatula or a spatula-cyto brush. One hundred married women participated in this single blind clinical trial. After all participants were interviewed, two samples were obtained from each: one with a spatula-cytobrush and another with an anatomical spatula. Slides were prepared and assessed by two pathologists for kappa coefficient analysis. Cell adequacy was 96.1 % in anatomical spatula method and 91.2 % in spatula-cyto brush method (p= 0.016). The rates for endocervical cells and metaplasia cells were 70.6%and 24.5%, respectively, with the anatomical spatula method and 69.6% and 24.5% using a spatula-cytobrush (p<0.001). No one reported pain and the amount of bleeding was 38.2% in both methods (p>0.05). In addition, there were no statistically significant differences regarding infection and inflammatory reactions (p>0.05). Based on the findings of this study, the results of sampling with anatomical spatula were more acceptable and better than those of spatula-cytobrush sampling.

  20. [Study of Japanese anatomical terms, such as 'sphenoid bone'].

    PubMed

    Sawai, Tadashi

    2008-12-01

    Japanese anatomical terms (butterfly-shaped bone) have an interesting history. Galen named a bone (wedge-like). This Greek term was introduced into Latin anatomical texts by transcribing into 'os sphnoides' or translating it as 'os cuneiforme'. Both terms mean equally wedge-like bone. From 16th century on, these two terms prevailed in European anatomical textbooks, but in 18th century some anatomists merged this bone with some kinds of winged creatures and named their wings "Ala major' and 'Ala minor'. In mid-19th century English-Chinese anatomical book, this bone was named (butterfly bone) by a medical missionary Benjamin Hobson. This term was introduced into Japanese textbooks. In Meiji Era both terms were used in Japanese textbooks, and (wedged-like bone). Some anatomists insisted on using because this echoed original Latin term's sense. Eventually, Japanese Associations of Anatomists adopted in 1943.

  1. A Retrospective Survival Analysis of Anatomic and Prognostic Stage Group Based on the American Joint Committee on Cancer 8th Edition Cancer Staging Manual in Luminal B Human Epidermal Growth Factor Receptor 2-negative Breast Cancer.

    PubMed

    Xu, Ling; Li, Jiang-Hong; Ye, Jing-Ming; Duan, Xue-Ning; Cheng, Yuan-Jia; Xin, Ling; Liu, Qian; Zhou, Bin; Liu, Yin-Hua

    2017-08-20

    Current understanding of tumor biology suggests that breast cancer is a group of diseases with different intrinsic molecular subtypes. Anatomic staging system alone is insufficient to provide future outcome information. The American Joint Committee on Cancer (AJCC) expert panel updated the 8th edition of the staging manual with prognostic stage groups by incorporating biomarkers into the anatomic stage groups. In this study, we retrospectively analyzed the data from our center in China using the anatomic and prognostic staging system based on the AJCC 8th edition staging manual. We reviewed the data from January 2008 to December 2014 for cases with Luminal B Human Epidermal Growth Factor Receptor 2 (HER2)-negative breast cancer in our center. All cases were restaged using the AJCC 8th edition anatomic and prognostic staging system. The Kaplan-Meier method and log-rank test were used to compare the survival differences between different subgroups. SPSS software version 19.0 (IBM Corp., Armonk, NY, USA) was used for the statistical analyses. This study consisted of 796 patients with Luminal B HER-negative breast cancer. The 5-year disease-free survival (DFS) of 769 Stage I-III patients was 89.7%, and the 5-year overall survival (OS) of all 796 patients was 91.7%. Both 5-year DFS and 5-year OS were significantly different in the different anatomic and prognostic stage groups. There were 372 cases (46.7%) assigned to a different group. The prognostic Stage II and III patients restaged from anatomic Stage III had significant differences in 5-year DFS (χ2 = 11.319, P= 0.001) and 5-year OS (χ2 = 5.225, P= 0.022). In addition, cases restaged as prognostic Stage I, II, or III from the anatomic Stage II group had statistically significant differences in 5-year DFS (χ2 = 6.510, P= 0.039) but no significant differences in 5-year OS (χ2 = 5.087, P= 0.079). However, the restaged prognostic Stage I and II cases from anatomic Stage I had no statistically significant

  2. The anatomical basis for wrinkles.

    PubMed

    Pessa, Joel E; Nguyen, Hang; John, George B; Scherer, Philipp E

    2014-02-01

    Light and electron microscopy have not identified a distinct anatomical structure associated with either skin wrinkles or creases, and a histological difference between wrinkled and adjacent skin has not been identified. The authors investigate whether facial wrinkles are related to underlying lymphatic vessels and perilymphatic fat. Lymphatic vessels with a specialized tube of perilymphatic fat were identified beneath palmar creases. Sections of skin, adipose tissue, and muscle were harvested from each of 13 cadavers. Three sites were investigated: the transverse forehead crease, lateral orbicularis oculi wrinkle (crow's feet), and the nasojugal crease. The tissue was paraffin embedded and processed. Two-step indirect immunohistochemistry was performed, and images were examined using laser confocal microscopy. Measurements were taken with software. Every wrinkle examined was found above and within ±1 mm of a major lymphatic vessel and its surrounding tube of adipose tissue. The results satisfied our null hypothesis and were statistically significant. Lymphatic vessels were identified by positive immunofluorescence as well as histological criteria. These findings have been further validated by fluorochrome tracer studies. An anatomical basis for wrinkles was identified among the specimens studied. Lymphatic vessels, along with the surrounding distinct perilymphatic fat, traveled directly beneath wrinkles and creases. Lymphatic dysregulation leads to inflammation, scarring, and fibrosis, but inadvertent injection of these vessels can be avoided with anatomical knowledge.

  3. The effect of anatomic differences on the relationship between renal artery and diaphragmatic crus.

    PubMed

    Esen, K; Tok, S; Balci, Yuksel; Apaydin, F D; Kara, E; Uzmansel, D

    2018-01-01

    The aim of this study is to investigate the effect of anatomic differences on the relationship between renal artery and diaphragmatic crus via the touch of two structures. The study included dynamic computed tomography (CT) scans of 308 patients performed mainly for characterisation of liver and renal masses. Anatomic differences including the thickness of the diaphragmatic crus, the localisation of renal artery ostium at the wall of aorta, the level of renal artery origin with respect to superior mesenteric artery were evaluated. Statistical relationships between renal artery-diaphragmatic crus contact and the anatomic differences were assessed. Thickness of the diaphragmatic crus at the level of renal artery origin exhibited a statistically significant relationship to renal artery-diaphragmatic crus contact at the left (p < 0.001) and right side (p < 0.001). There was a statistically significant relationship between high renal artery origin and renal artery- -diaphragmatic crus contact at the left (p < 0.001) and right side (p = 0.01). The localisation of renal artery ostium at the wall of aorta (right side, p = 0.436, left side, p = 0.681) did not demonstrate a relationship to renal artery-diaphragmatic crus contact. Thickness of the diaphragmatic crus and high renal artery origin with respect to superior mesenteric artery are crucial anatomic differences determining the relationship of renal artery and diaphragmatic crus. (Folia Morphol 2018; 77, 1: 22-28).

  4. The Integral Theory System Questionnaire: an anatomically directed questionnaire to determine pelvic floor dysfunctions in women.

    PubMed

    Wagenlehner, Florian Martin Erich; Fröhlich, Oliver; Bschleipfer, Thomas; Weidner, Wolfgang; Perletti, Gianpaolo

    2014-06-01

    Anatomical damage to pelvic floor structures may cause multiple symptoms. The Integral Theory System Questionnaire (ITSQ) is a holistic questionnaire that uses symptoms to help locate damage in specific connective tissue structures as a guide to reconstructive surgery. It is based on the integral theory, which states that pelvic floor symptoms and prolapse are both caused by lax suspensory ligaments. The aim of the present study was to psychometrically validate the ITSQ. Established psychometric properties including validity, reliability, and responsiveness were considered for evaluation. Criterion validity was assessed in a cohort of 110 women with pelvic floor dysfunctions by analyzing the correlation of questionnaire responses with objective clinical data. Test-retest was performed with questionnaires from 47 patients. Cronbach's alpha and "split-half" reliability coefficients were calculated for inner consistency analysis. Psychometric properties of ITSQ were comparable to the ones of previously validated Pelvic Floor Questionnaires. Face validity and content validity were approved by an expert group of the International Collaboration of Pelvic Floor surgeons. Convergent validity assessed using Bayesian method was at least as accurate as the expert assessment of anatomical defects. Objective data measurement in patients demonstrated significant correlations with ITSQ domains fulfilling criterion validity. Internal consistency values ranked from 0.85 to 0.89 in different scenarios. The ITSQ proofed accurate and is able to serve as a holistic Pelvic Floor Questionnaire directing symptoms to site-specific pelvic floor reconstructive surgery.

  5. An anatomic study of nipple position and areola size in Asian men.

    PubMed

    Kasai, Shogo; Shimizu, Yusuke; Nagasao, Tomohisa; Ohnishi, Fumio; Minabe, Toshiharu; Momosawa, Akira; Kishi, Kazuo

    2015-02-01

    In planning gender-reassignment surgery for biological women and treating men with gynecomastia, surgeons must have a thorough understanding of anatomically correct nipple positions and appropriate areola sizes in men. The authors sought to determine whether body height or body mass index (BMI) affects nipple position or areola size in men. Anatomic measurements of the nipples and areolae of 50 Japanese men were obtained. A relative coordinate system was defined, where the medial-lateral and superior-inferior positions of the nipple were quantitatively indicated by distance ratios between anatomic landmarks. Nipple positions were evaluated for each patient by referring to this coordinate system, and the positions were compared between groups categorized by body height or BMI. Nipple position was not significantly affected by body height. However, the nipple tended to be located more laterally in participants with higher BMI. The vertical nipple position differed between standing and supine positions. Tall men had larger areolae than short men; however, areola size did not differ with respect to BMI. Nipple position and areola size vary by body shape. Consideration of the differences is recommended when performing procedures such as female-to-male gender-reassignment surgery or correction of gynecomastia. © 2015 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com.

  6. Gender Differences of Airway Dimensions in Anatomically Matched Sites on CT in Smokers

    PubMed Central

    Kim, Yu-Il; Schroeder, Joyce; Lynch, David; Newell, John; Make, Barry; Friedlander, Adam; Estépar, Raúl San José; Hanania, Nicola A.; Washko, George; Murphy, James R.; Wilson, Carla; Hokanson, John E.; Zach, Jordan; Butterfield, Kiel; Bowler, Russell P.

    2013-01-01

    Rationale and Objectives There are limited data on, and controversies regarding gender differences in the airway dimensions of smokers. Multi-detector CT (MDCT) images were analyzed to examine whether gender could explain differences in airway dimensions of anatomically matched airways in smokers. Materials and Methods We used VIDA imaging software to analyze MDCT scans from 2047 smokers (M:F, 1021:1026) from the COPDGene® cohort. The airway dimensions were analyzed from segmental to subsubsegmental bronchi. We compared the differences of luminal area, inner diameter, wall thickness, wall area percentage (WA%) for each airway between men and women, and multiple linear regression including covariates (age, gender, body sizes, and other relevant confounding factors) was used to determine the predictors of each airway dimensions. Results Lumen area, internal diameter and wall thickness were smaller for women than men in all measured airway (18.4 vs 22.5 mm2 for segmental bronchial lumen area, 10.4 vs 12.5 mm2 for subsegmental bronchi, 6.5 vs 7.7 mm2 for subsubsegmental bronchi, respectively p < 0.001). However, women had greater WA% in subsegmental and subsubsegmental bronchi. In multivariate regression, gender remained one of the most significant predictors of WA%, lumen area, inner diameter and wall thickness. Conclusion Women smokers have higher WA%, but lower luminal area, internal diameter and airway thickness in anatomically matched airways as measured by CT scan than do male smokers. This difference may explain, in part, gender differences in the prevalence of COPD and airflow limitation. PMID:21756032

  7. PINUS cembra L: histo-anatomical features, antioxidant enzyme activities and heavy metal contents of leaves and long shoots.

    PubMed

    Lungu, Cristina; Stănescu, Irina; Cojocaru, Sabina Ioana; Ciobanu, C; Ivănescu, Bianca; Miron, Anca

    2015-01-01

    This study aimed to investigate the histo-anatomical features of the long shoots and leaves (young and mature) of Pinus cembra L.. The activity of antioxidant enzymatic systems and the content of heavy metals were also evaluated. For the histo-anatomical study, the cross-sections were performed by usual techniques. The activity of antioxidant enzymatic systems (superoxide dismutase, catalase and peroxidase) was evaluated by spectrophotometric methods. The content of heavy metals was determined by atomic absorption spectroscopy. The cross-section through the long shoots shows many resiniferous canals and a periderm of variable thickness. The leaf has a triangular shape and only two vascular bundles in the inferior and upper levels. The highest level of superoxide dismutase activity (344.90 U/mg protein) was determined in the long shoots collected from a cembran pine in Vatra Dornei, while the highest level of peroxidase activity (7611.11 U/mg protein) was found in the leaves collected in Calimani Mountains. Cd level in all samples was under the quantification limit. Higher levels of Pb were determined in the long shoots (3 μg/g dry weight for the vegetal material collected in Vatra Dornei and 2.86 μg/g dry weight for the vegetal material collected in Calimani Mountains). Pinus cembra L. leaves show specific elements of subgenus Strobus (a triangular shape of the cross section, one single vascular bundle and two resiniferous canals). The results obtained for the superoxide dismutase and peroxidase activities corroborated with those obtained for the heavy metal contents indicate that antioxidant enzymes play an important role in the protection of Pinus cembra L. against exogenous stress factors.

  8. Toledo School of Translators and their influence on anatomical terminology.

    PubMed

    Arráez-Aybar, Luis-Alfonso; Bueno-López, José-L; Raio, Nicolas

    2015-03-01

    Translation facilitates transmission of knowledge between cultures. The fundamental transfer of anatomic terminology from the Ancient Greek and Islamic Golden Age cultures, to medieval Latin Christendom took place in the so-called Toledo School of Translators in the 12th-13th centuries. Translations made in Toledo circulated widely across Europe. They were the foundation of scientific thinking that was born in the boards of first universities. In Toledo, Gerard of Cremona translated Avicenna's Canon of Medicine, the key work of Islamic Golden Age of medicine. Albertus Magnus, Mondino de Luzzi and Guy de Chauliac, the leading authors of anatomical Latin words in the Middle Ages, founded their books on Gerard's translations. The anatomical terms of the Canon retain auctoritas up to the Renaissance. Thus, terms coined by Gerard such as diaphragm, orbit, pupil or sagittal remain relevant in the current official anatomical terminology. The aim of the present paper is to bring new attention to the highly significant influence that the Toledo School of Translators had in anatomical terminology. For this, we shall review here the onomastic origins of a number of anatomical terms (additamentum; coracoid process; coxal; false ribs; femur; panniculus; spondylus; squamous sutures; thorax; xiphoid process, etc.) which are still used today. Copyright © 2015 Elsevier GmbH. All rights reserved.

  9. Anatomical location differences between mutated and wild-type isocitrate dehydrogenase 1 in low-grade gliomas.

    PubMed

    Yu, Jinhua; Shi, Zhifeng; Ji, Chunhong; Lian, Yuxi; Wang, Yuanyuan; Chen, Liang; Mao, Ying

    2017-10-01

    Anatomical location of gliomas has been considered as a factor implicating the contributions of a specific precursor cells during the tumor growth. Isocitrate dehydrogenase 1 (IDH1) is a pathognomonic biomarker with a significant impact on the development of gliomas and remarkable prognostic effect. The correlation between anatomical location of tumor and IDH1 states for low-grade gliomas was analyzed quantitatively in this study. Ninety-two patients diagnosed of low-grade glioma pathologically were recruited in this study, including 65 patients with IDH1-mutated glioma and 27 patients with wide-type IDH1. A convolutional neural network was designed to segment the tumor from three-dimensional magnetic resonance imaging images. Voxel-based lesion symptom mapping was then employed to study the tumor location distribution differences between gliomas with mutated and wild-type IDH1. In order to characterize the location differences quantitatively, the Automated Anatomical Labeling Atlas was used to partition the standard brain atlas into 116 anatomical volumes of interests (AVOIs). The percentages of tumors with different IDH1 states in 116 AVOIs were calculated and compared. Support vector machine and AdaBoost algorithms were used to estimate the IDH1 status based on the 116 location features of each patient. Experimental results proved that the quantitative tumor location measurement could be a very important group of imaging features in biomarker estimation based on radiomics analysis of glioma.

  10. Standard Anatomic Terminologies: Comparison for Use in a Health Information Exchange–Based Prior Computed Tomography (CT) Alerting System

    PubMed Central

    Lowry, Tina; Vreeman, Daniel J; Loo, George T; Delman, Bradley N; Thum, Frederick L; Slovis, Benjamin H; Shapiro, Jason S

    2017-01-01

    Background A health information exchange (HIE)–based prior computed tomography (CT) alerting system may reduce avoidable CT imaging by notifying ordering clinicians of prior relevant studies when a study is ordered. For maximal effectiveness, a system would alert not only for prior same CTs (exams mapped to the same code from an exam name terminology) but also for similar CTs (exams mapped to different exam name terminology codes but in the same anatomic region) and anatomically proximate CTs (exams in adjacent anatomic regions). Notification of previous same studies across an HIE requires mapping of local site CT codes to a standard terminology for exam names (such as Logical Observation Identifiers Names and Codes [LOINC]) to show that two studies with different local codes and descriptions are equivalent. Notifying of prior similar or proximate CTs requires an additional mapping of exam codes to anatomic regions, ideally coded by an anatomic terminology. Several anatomic terminologies exist, but no prior studies have evaluated how well they would support an alerting use case. Objective The aim of this study was to evaluate the fitness of five existing standard anatomic terminologies to support similar or proximate alerts of an HIE-based prior CT alerting system. Methods We compared five standard anatomic terminologies (Foundational Model of Anatomy, Systematized Nomenclature of Medicine Clinical Terms, RadLex, LOINC, and LOINC/Radiological Society of North America [RSNA] Radiology Playbook) to an anatomic framework created specifically for our use case (Simple ANatomic Ontology for Proximity or Similarity [SANOPS]), to determine whether the existing terminologies could support our use case without modification. On the basis of an assessment of optimal terminology features for our purpose, we developed an ordinal anatomic terminology utility classification. We mapped samples of 100 random and the 100 most frequent LOINC CT codes to anatomic regions in each

  11. TNM: evolution and relation to other prognostic factors.

    PubMed

    Sobin, Leslie H

    2003-01-01

    The TNM Classification describes the anatomic extent of cancer. TNM's ability to separately classify the individual tumor (T), node (N), and metastasis (M) elements and then group them into stages differs from other cancer staging classifications (e.g., Dukes), which are only concerned with summarized groups. The objectives of the TNM Classification are to aid the clinician in the planning of treatment, give some indication of prognosis, assist in the evaluation of the results of treatment, and facilitate the exchange of information. During the past 50 years, the TNM system has evolved under the influence of advances in diagnosis and treatment. Radiographic imaging (e.g., endoscopic ultrasound for the depth of invasion of esophageal and rectal tumors) has improved the accuracy of the clinical T, N, and M classifications. Advances in treatment have necessitated more detail in some T4 categories. Developments in multimodality therapy have increased the importance of the "y" symbol and the R (residual tumor) classification. New surgical techniques have resulted in the elaboration of the sentinel node (sn) symbol. The use of immunohistochemistry has resulted in the classification of isolated tumor cells and their distinction from micrometastasis. The most important challenge facing users of the TNM Classification is how it should interface with the large number of non-anatomic prognostic factors that are currently in use or under study. As non-anatomic prognostic factors become widely used, the TNM system provides an inviting foundation upon which to build a prognostic classification; however, this carries a risk that the system will be overwhelmed by a variety of prognostic data. An anatomic extent-of-disease classification is needed to aid practitioners in selecting the initial therapeutic approach, stratifying patients for therapeutic studies, evaluating non-anatomic prognostic factors at specific anatomic stages, comparing the weight of non-anatomic factors with

  12. Is the Keros classification alone enough to identify patients with the 'dangerous ethmoid'? An anatomical study.

    PubMed

    Skorek, Andrzej; Tretiakow, Dmitry; Szmuda, Tomasz; Przewozny, Tomasz

    2017-02-01

    By means of three-dimensional display of the critical measurements, the authors suggest a novel definition of 'dangerous ethmoid'. Parallel to Keros type III, the proposed determining factors include: olfactory fossa width >6 mm, its distance to the medial nasal concha (turbinate) <20 mm and to the orbit interval of <10 mm. Clinical evaluation of these preliminary criteria based only on radiological data is required and underway. Detailed pre-operative assessment of sinus computer tomography (CT) scans reduces the frequency of severe complications in patients undergoing endoscopic sinus surgery (ESS). The authors aimed to identify a sub-set of anatomical features pre-disposing to major post-operative complications. Sinus computer tomography (CT) scans of patients of a single institution qualified for ESS were examined. Besides the Keros classification, authors focused on the anatomic measurements as follows: the olfactory fossa depth, width, and its distance from the medial nasal concha and the medial wall of the orbit (referred to as 'critical measurements'). The sample comprised 120 consecutive CT exams, without clinical validation. Keros type I, II, and III was noted in 9.2%, 75.8%, and 15.0% of cases, respectively. Despite some statistically significant correlations, it was not possible to identify the patient age, sex, and side of body clearly correlating with the critical measurements.

  13. Optogenetic manipulation of anatomical re-entry by light-guided generation of a reversible local conduction block.

    PubMed

    Watanabe, Masaya; Feola, Iolanda; Majumder, Rupamanjari; Jangsangthong, Wanchana; Teplenin, Alexander S; Ypey, Dirk L; Schalij, Martin J; Zeppenfeld, Katja; de Vries, Antoine A F; Pijnappels, Daniël A

    2017-03-01

    Anatomical re-entry is an important mechanism of ventricular tachycardia, characterized by circular electrical propagation in a fixed pathway. It's current investigative and therapeutic approaches are non-biological, rather unspecific (drugs), traumatizing (electrical shocks), or irreversible (ablation). Optogenetics is a new biological technique that allows reversible modulation of electrical function with unmatched spatiotemporal precision using light-gated ion channels. We therefore investigated optogenetic manipulation of anatomical re-entry in ventricular cardiac tissue. Transverse, 150-μm-thick ventricular slices, obtained from neonatal rat hearts, were genetically modified with lentiviral vectors encoding Ca2+-translocating channelrhodopsin (CatCh), a light-gated depolarizing ion channel, or enhanced yellow fluorescent protein (eYFP) as control. Stable anatomical re-entry was induced in both experimental groups. Activation of CatCh was precisely controlled by 470-nm patterned illumination, while the effects on anatomical re-entry were studied by optical voltage mapping. Regional illumination in the pathway of anatomical re-entry resulted in termination of arrhythmic activity only in CatCh-expressing slices by establishing a local and reversible, depolarization-induced conduction block in the illuminated area. Systematic adjustment of the size of the light-exposed area in the re-entrant pathway revealed that re-entry could be terminated by either wave collision or extinction, depending on the depth (transmurality) of illumination. In silico studies implicated source-sink mismatches at the site of subtransmural conduction block as an important factor in re-entry termination. Anatomical re-entry in ventricular tissue can be manipulated by optogenetic induction of a local and reversible conduction block in the re-entrant pathway, allowing effective re-entry termination. These results provide distinctively new mechanistic insight into re-entry termination and a

  14. Greek language: analysis of the cardiologic anatomical etymology: past and present.

    PubMed

    Bezas, Georges; Werneck, Alexandre Lins

    2012-01-01

    The Greek language, the root of most Latin anatomical terms, is deeply present in the Anatomical Terminology. Many studies seek to analyze etymologically the terms stemming from the Greek words. In most of these studies, the terms appear defined according to the etymological understanding of the respective authors at the time of its creation. Therefore, it is possible that the terms currently used are not consistent with its origin in ancient Greek words. We selected cardiologic anatomical terms derived from Greek words, which are included in the International Anatomical Terminology. We performed an etymological analysis using the Greek roots present in the earliest terms. We compared the cardiologic anatomical terms currently used in Greece and Brazil to the Greek roots originating from the ancient Greek language. We used morphological decomposition of Greek roots, prefixes, and suffixes. We also verified their use on the same lexicons and texts from the ancient Greek language. We provided a list comprising 30 cardiologic anatomical terms that have their origins in ancient Greek as well as their component parts in the International Anatomical Terminology. We included the terms in the way they were standardized in Portuguese, English, and Modern Greek as well as the roots of the ancient Greek words that originated them. Many works deal with the true origin of words (etymology) but most of them neither returns to the earliest roots nor relate them to their use in texts of ancient Greek language. By comparing the world's greatest studies on the etymology of Greek words, this paper tries to clarify the differences between the true origin of the Greek anatomical terms as well as the origins of the cardiologic anatomical terms more accepted today in Brazil by health professionals.

  15. Presentation of Anatomical Variations Using the Aurasma Mobile App

    PubMed Central

    Bézard, Georg; Lozanoff, Beth K; Labrash, Steven; Lozanoff, Scott

    2015-01-01

    Knowledge of anatomical variations is critical to avoid clinical complications and it enables an understanding of morphogenetic mechanisms. Depictions are comprised of photographs or illustrations often limiting appreciation of three-dimensional (3D) spatial relationships. The purpose of this study is to describe an approach for presenting anatomical variations utilizing video clips emphasizing 3D anatomical relationships delivered on personal electronic devices. An aberrant right subclavian artery (ARSA) was an incidental finding in a routine dissection of an 89-year-old man cadaver during a medical student instructional laboratory. The specimen was photographed and physical measurements were recorded. Three-dimensional models were lofted and rendered with Maya software and converted as Quicktime animations. Photographs of the first frame of the animations were recorded and registered with Aurasma Mobile App software (www.aurasma.com). Resulting animations were viewed on mobile devices. The ARSA model can be manipulated on the mobile device enabling the student to view and appreciate spatial relationships. Model elements can be de-constructed to provide even greater spatial resolution of anatomical relationships. Animations provide a useful approach for visualizing anatomical variations. Future work will be directed at creating a library of variants and underlying mechanism of formation for presentation through the Aurasma application. PMID:26793410

  16. Round and Oval Window Anatomic Variability: Its Implication for the Vibroplasty Technique.

    PubMed

    Mancheño, Marta; Aristegui, Miguel; Sañudo, Jose Ramon

    2017-06-01

    The objective of this study is to evaluate the anatomical variability of round and oval window regions and its relationship with their closest structures, to determine its implication on the fitting and stabilization of the middle ear implant Vibrant Soundbridge. Variations of the anatomy of round and oval window regions were assessed in a total of 85 human dissected temporal bones. Afterward, we evaluated the adaptation and subsequent stabilization of the floating mass transducer (FMT) of the Vibrant Soundbridge in 67 cases in round window (RW) and in 22 cases in oval window (OW), and the influence that the variability of the different anatomical features examined had on this stabilization. We also assessed access and surgeon's view of the RW niche through the facial recess approach. Stabilization of the FMT in the RW was achieved in 53 (79%) of the 67 cases; we found that the less favorable anatomical conditions for stabilization were: membrane smaller than 1.5 mm, presence of a high jugular bulb and a narrow or very narrow RW niche. Frequently, two or more of these conditions happened simultaneously. In seven cases (22%) access to the RW through facial recess approach did not allow positioning the FMT in place. OW stabilization succeeded in 18 (82%) of the 22 cases. Round and oval window vibroplasty are difficult surgical techniques. To place the FMT directly on the OW may be easier as we do not have to drill the niche. In both regions there are some anatomical conditions that hinder fitting the FMT and even make it impossible. Once fitted, the main problem is to achieve good stabilization of the device.

  17. Severity scores in trauma patients admitted to ICU. Physiological and anatomic models.

    PubMed

    Serviá, L; Badia, M; Montserrat, N; Trujillano, J

    2018-02-02

    The goals of this project were to compare both the anatomic and physiologic severity scores in trauma patients admitted to intensive care unit (ICU), and to elaborate mixed statistical models to improve the precision of the scores. A prospective study of cohorts. The combined medical/surgical ICU in a secondary university hospital. Seven hundred and eighty trauma patients admitted to ICU older than 16 years of age. Anatomic models (ISS and NISS) were compared and combined with physiological models (T-RTS, APACHE II [APII], and MPM II). The probability of death was calculated following the TRISS method. The discrimination was assessed using ROC curves (ABC [CI 95%]), and the calibration using the Hosmer-Lemeshoẃs H test. The mixed models were elaborated with the tree classification method type Chi Square Automatic Interaction Detection. A 14% global mortality was recorded. The physiological models presented the best discrimination values (APII of 0.87 [0.84-0.90]). All models were affected by bad calibration (P<.01). The best mixed model resulted from the combination of APII and ISS (0.88 [0.83-0.90]). This model was able to differentiate between a 7.5% mortality for elderly patients with pathological antecedents and a 25% mortality in patients presenting traumatic brain injury, from a pool of patients with APII values ranging from 10 to 17 and an ISS threshold of 22. The physiological models perform better than the anatomical models in traumatic patients admitted to the ICU. Patients with low scores in the physiological models require an anatomic analysis of the injuries to determine their severity. Copyright © 2017 Elsevier España, S.L.U. y SEMICYUC. All rights reserved.

  18. Anatomical Variations of the Right Adrenal Vein: Concordance Between Multidetector Computed Tomography and Catheter Venography.

    PubMed

    Omura, Kensuke; Ota, Hideki; Takahashi, Yuuki; Matsuura, Tomonori; Seiji, Kazumasa; Arai, Yoichi; Morimoto, Ryo; Satoh, Fumitoshi; Takase, Kei

    2017-03-01

    Adrenal venous sampling is the most reliable diagnostic procedure to determine surgical indications in primary aldosteronism. Because guidelines recommend multidetector computed tomography (CT) to evaluate the adrenal gland, some past reports used multidetector CT as a guide for adrenal venous sampling. However, the detailed anatomy of the right adrenal vein and its relationship with an accessory hepatic vein remains uncertain. The purpose of this study was to describe detailed anatomical variations of the right adrenal vein and to determine the concordance between CT and catheter venography in patients with primary aldosteronism. In total, 440 consecutive patients who underwent adrenal venous sampling were included. Four-phase dynamic CT was performed. Anatomical locations and variations of the right adrenal vein and its relationship with the accessory hepatic vein were compared with catheter venographic findings. Successful catheterization was achieved in 437 patients (99%). The right adrenal vein was visualized in the late arterial phase with CT in 420 patients (95%). The right adrenal vein formed a common trunk with the accessory hepatic vein in 87 patients (20%). CT identified the correct craniocaudal level of the orifice in 354 patients (84%). Anatomical variations, location, and angle of inflow of the right adrenal vein based on CT demonstrated high concordance with catheter venography. CT may provide useful information for preparation before adrenal venous sampling. © 2017 American Heart Association, Inc.

  19. Anatomical connections of the visual word form area.

    PubMed

    Bouhali, Florence; Thiebaut de Schotten, Michel; Pinel, Philippe; Poupon, Cyril; Mangin, Jean-François; Dehaene, Stanislas; Cohen, Laurent

    2014-11-12

    The visual word form area (VWFA), a region systematically involved in the identification of written words, occupies a reproducible location in the left occipitotemporal sulcus in expert readers of all cultures. Such a reproducible localization is paradoxical, given that reading is a recent invention that could not have influenced the genetic evolution of the cortex. Here, we test the hypothesis that the VWFA recycles a region of the ventral visual cortex that shows a high degree of anatomical connectivity to perisylvian language areas, thus providing an efficient circuit for both grapheme-phoneme conversion and lexical access. In two distinct experiments, using high-resolution diffusion-weighted data from 75 human subjects, we show that (1) the VWFA, compared with the fusiform face area, shows higher connectivity to left-hemispheric perisylvian superior temporal, anterior temporal and inferior frontal areas; (2) on a posterior-to-anterior axis, its localization within the left occipitotemporal sulcus maps onto a peak of connectivity with language areas, with slightly distinct subregions showing preferential projections to areas respectively involved in grapheme-phoneme conversion and lexical access. In agreement with functional data on the VWFA in blind subjects, the results suggest that connectivity to language areas, over and above visual factors, may be the primary determinant of VWFA localization. Copyright © 2014 the authors 0270-6474/14/3415402-13$15.00/0.

  20. Contribution to the anatomical nomenclature concerning upper limb anatomy.

    PubMed

    Kachlik, David; Musil, Vladimir; Baca, Vaclav

    2017-04-01

    The aim of this article is to revise and extend the existing sections of Terminologia Anatomica dealing with the upper limb structures, which nomenclature belongs to its most neglected and not developing parts, and to justify the use of the proposed anatomical terms in the clinical practice, research, and education. A sample collected from own educational and research experience was matched in the main anatomical textbooks as well as old and recent anatomical journals and compared with four versions of the official Latin anatomical nomenclatures. The authors summarize here 145 terms, completed with their definitions or explanations, concerning both constant and variable (inconstant) morphological structures (bones, joints, muscles, vessels, and nerves) of the pectoral girdle, arm, cubital region, forearm, wrist, and hand, completed with some grammar remarks and several general terms. After a broad discussion on this topic, the Terminologia Anatomica should be revised and extend with the listed terms (or their equivalents).

  1. Interactive anatomical teaching: Integrating radiological anatomy within topographic anatomy.

    PubMed

    Abed Rabbo, F; Garrigues, F; Lefèvre, C; Seizeur, R

    2016-03-01

    Hours attributed to teaching anatomy have been reduced in medical curricula through out the world. In consequence, changes in anatomical curriculum as well as in teaching methods are becoming necessary. New methods of teaching are being evaluated. We present in the following paper an example of interactive anatomical teaching associating topographic anatomy with ultrasonographic radiological anatomy. The aim was to explicitly show anatomical structures of the knee and the ankle through dissection and ultrasonography. One cadaver was used as an ultrasonographic model and the other was dissected. Anatomy of the knee and ankle articulations was studied through dissection and ultrasonography. The students were able to simultaneously assimilate both anatomical aspects of radiological and topographic anatomy. They found the teaching very helpful and practical. This body of work provides example of a teaching method combining two important aspects of anatomy to help the students understand both aspects simultaneously. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  2. A study on automated anatomical labeling to arteries concerning with colon from 3D abdominal CT images

    NASA Astrophysics Data System (ADS)

    Hoang, Bui Huy; Oda, Masahiro; Jiang, Zhengang; Kitasaka, Takayuki; Misawa, Kazunari; Fujiwara, Michitaka; Mori, Kensaku

    2011-03-01

    This paper presents an automated anatomical labeling method of arteries extracted from contrasted 3D CT images based on multi-class AdaBoost. In abdominal surgery, understanding of vasculature related to a target organ such as the colon is very important. Therefore, the anatomical structure of blood vessels needs to be understood by computers in a system supporting abdominal surgery. There are several researches on automated anatomical labeling, but there is no research on automated anatomical labeling to arteries concerning with the colon. The proposed method obtains a tree structure of arteries from the artery region and calculates features values of each branch. These feature values are thickness, curvature, direction, and running vectors of branch. Then, candidate arterial names are computed by classifiers that are trained to output artery names. Finally, a global optimization process is applied to the candidate arterial names to determine final names. Target arteries of this paper are nine lower abdominal arteries (AO, LCIA, RCIA, LEIA, REIA, SMA, IMA, LIIA, RIIA). We applied the proposed method to 14 cases of 3D abdominal contrasted CT images, and evaluated the results by leave-one-out scheme. The average precision and recall rates of the proposed method were 87.9% and 93.3%, respectively. The results of this method are applicable for anatomical name display of surgical simulation and computer aided surgery.

  3. Analysis of anatomic periarticular tibial plate fit on normal adults.

    PubMed

    Goyal, Kanu S; Skalak, Anthony S; Marcus, Randall E; Vallier, Heather A; Cooperman, Daniel R

    2007-08-01

    Implant manufacturers are producing anatomically contoured periarticular plates to improve the treatment of proximal tibia fractures. We assessed the accuracy of the designation anatomic. We applied eight-hole medial and lateral anatomically contoured periarticular plates to 101 cadaveric tibiae. The tibiae and the plate fits were mapped, quantified, and analyzed using a MicroScribe G2LX digitizer, Rhinoceros software, and MATLAB software. By corresponding the clinical appearance of good fit with our digital findings, we created numerical criteria for plate fit in three planes: coronal (volume of free space between the plate and bone), sagittal (alignment with the tibial plateau and shaft), and axial (match in curvature between the proximal horizontal part of the plate and the tibial plateau). An anatomic fit should mirror the shape of the tibia in all three planes, and only four medial and four lateral plate fits qualified. Recognizing and understanding the substantial variations in fit that exist between anatomically contoured plates and the tibia may help lead to a more stable fixation and prevent malreduction of the fracture and/or soft tissue impingement.

  4. Opening wedge and anatomic-specific plates in foot and ankle applications.

    PubMed

    Kluesner, Andrew J; Morris, Jason B

    2011-08-01

    As surgeons continually push to improve techniques and outcomes, anatomic-specific and procedure-specific fixation options are becoming increasingly available. The unique size, shape, and function of the foot provide an ideal framework for the use of anatomic-specific plates. These distinctive plate characteristics range from anatomic contouring and screw placements to incorporated step-offs and wedges. By optimizing support, compression, and stabilization, patients may return to weight bearing and activity sooner, improving outcomes. This article discusses anatomic-specific plates and their use in forefoot and rearfoot surgical procedures. Copyright © 2011 Elsevier Inc. All rights reserved.

  5. Effect of the anatomical site on telomere length and pref-1 gene expression in bovine adipose tissues

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yamada, Tomoya, E-mail: toyamada@affrc.go.jp; Higuchi, Mikito; Nakanishi, Naoto

    Adipose tissue growth is associated with preadipocyte proliferation and differentiation. Telomere length is a biological marker for cell proliferation. Preadipocyte factor-1 (pref-1) is specifically expressed in preadipocytes and acts as a molecular gatekeeper of adipogenesis. In the present study, we investigated the fat depot-specific differences in telomere length and pref-1 gene expression in various anatomical sites (subcutaneous, intramuscular and visceral) of fattening Wagyu cattle. Visceral adipose tissue expressed higher pref-1 mRNA than did subcutaneous and intramuscular adipose tissues. The telomere length in visceral adipose tissue tended to be longer than that of subcutaneous and intramuscular adipose tissues. The telomere lengthmore » of adipose tissue was not associated with adipocyte size from three anatomical sites. No significant correlation was found between the pref-1 mRNA level and the subcutaneous adipocyte size. In contrast, the pref-1 mRNA level was negatively correlated with the intramuscular and visceral adipocyte size. These results suggest that anatomical sites of adipose tissue affect the telomere length and expression pattern of the pref-1 gene in a fat depot-specific manner. - Highlights: • Visceral adipose tissue express higher pref-1 mRNA than other anatomical sites. • Telomere length in visceral adipose tissue is longer than other anatomical sites. • Telomere length of adipose tissue is not associated with adipocyte size. • Pref-1 mRNA is negatively correlated with intramuscular and visceral adipocyte size.« less

  6. Construction of a 3-D anatomical model for teaching temporal lobectomy.

    PubMed

    de Ribaupierre, Sandrine; Wilson, Timothy D

    2012-06-01

    Although we live and work in 3 dimensional space, most of the anatomical teaching during medical school is done on 2-D (books, TV and computer screens, etc). 3-D spatial abilities are essential for a surgeon but teaching spatial skills in a non-threatening and safe educational environment is a much more difficult pedagogical task. Currently, initial anatomical knowledge formation or specific surgical anatomy techniques, are taught either in the OR itself, or in cadaveric labs; which means that the trainee has only limited exposure. 3-D computer models incorporated into virtual learning environments may provide an intermediate and key step in a blended learning approach for spatially challenging anatomical knowledge formation. Specific anatomical structures and their spatial orientation can be further clinically contextualized through demonstrations of surgical procedures in the 3-D digital environments. Recordings of digital models enable learner reviews, taking as much time as they want, stopping the demonstration, and/or exploring the model to understand the anatomical relation of each structure. We present here how a temporal lobectomy virtual model has been developed to aid residents and fellows conceptualization of the anatomical relationships between different cerebral structures during that procedure. We suggest in comparison to cadaveric dissection, such virtual models represent a cost effective pedagogical methodology providing excellent support for anatomical learning and surgical technique training. Copyright © 2012 Elsevier Ltd. All rights reserved.

  7. The Anatomical Institute at the University of Greifswald during National Socialism: The procurement of bodies and their use for anatomical purposes.

    PubMed

    Alvermann, Dirk; Mittenzwei, Jan

    2016-05-01

    This is the first comprehensive account of body procurement at the Anatomical Institute at Greifswald University during National Socialism (NS). As in all other German anatomical departments, the bodies received during this period included increasing numbers of victims of the NS regime. Prior to 1939, 90% of all bodies came from hospitals, state nursing homes and mental institutions (Heil- und Pflegeanstalten), but dropped to less than 30% after 1941. While the total catchment area for body procurement decreased, the number of suppliers increased and included prisons, POW camps, Gestapo offices and military jurisdiction authorities. Among the 432 documented bodies delivered to the institute, 132 came from state nursing homes and mental institutions, mainly from Ueckermünde. These were bodies of persons, who probably were victims of "euthanasia" crimes. The Anatomical Institute also procured 46 bodies of forced laborers, of whom at least twelve had been executed. Other groups of victims included 21 bodies of executed Wehrmacht soldiers and 16 Russian prisoners of war from the camp Stalag II C in Greifswald, who had died of starvation and exhaustion. From 1941 onwards, the number of bodies delivered from prisons and penitentiaries greatly increased. In total, 60 bodies of prisoners, mainly from the penitentiary in Gollnow, were delivered to the Anatomical Institute. Greifswald Anatomical Institute was not just a passive recipient of bodies from all of these sources, but the anatomists actively lobbied with the authorities for an increased body supply for teaching and research purposes. Copyright © 2016 Elsevier GmbH. All rights reserved.

  8. Factors that determin color appearance and color classification.

    PubMed

    Janelidze, D

    2011-11-01

    The purpose of this work was to consider the objective and subjective factors involved in color perception and on their basis offer a color classification that would allow for determining which of these factors are significant for each particular class of colors. In the first part of the article it is considered that physical correlates of subjective sensation of color have mainly a dual nature and sometimes correlate with spectral-power content of light coming from a given area of visual scene to retina, and sometimes with surface reflectance of the given area. Other objective and subjective factors which participate in the formation of color appearance are also considered. According to the characteristics of the visual stimulus, viewing conditions and functional state of visual system, composition of objective and subjective factors participating in the formation of color appearance, as well as the share of each factor in this process are changeable. In the second part of the article one of the possible version of color classification according to which it is possible to distinguish nine different classes of colors is proposed. Among differences between these classes, the most noticeable is that in the case of all classes of color except constant colors, the physical parameter that determines the color category of a given area is the spectral-power distribution of the light coming from this area to the retina. However, in the case of constant colors, the physical parameter that determines the color category of a given area is its reflectance. In the case of considered different classes of colors, composition of objective and subjective factors participating in the formation of color appearance is different. The proposed classification allows determining which of these factors are significant in the case of each specific class of color.

  9. The Science and Politics of Naming: Reforming Anatomical Nomenclature, ca. 1886-1955.

    PubMed

    Buklijas, Tatjana

    2017-04-01

    Anatomical nomenclature is medicine's official language. Early in their medical studies, students are expected to memorize not only the bodily geography but also the names for all the structures that, by consensus, constitute the anatomical body. The making and uses of visual maps of the body have received considerable historiographical attention, yet the history of production, communication, and reception of anatomical names-a history as long as the history of anatomy itself-has been studied far less. My essay examines the reforms of anatomical naming between the first modern nomenclature, the 1895 Basel Nomina Anatomica (BNA), and the 1955 Nomina Anatomica Parisiensia (NAP, also known as PNA), which is the basis for current anatomical terminology. I focus on the controversial and ultimately failed attempt to reform anatomical nomenclature, known as Jena Nomina Anatomica (INA), of 1935. Discussions around nomenclature reveal not only how anatomical names are made and communicated, but also the relationship of anatomy with the clinic; disciplinary controversies within anatomy; national traditions in science; and the interplay between international and scientific disciplinary politics. I show how the current anatomical nomenclature, a successor to the NAP, is an outcome of both political and disciplinary tensions that reached their peak before 1945. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  10. 16 CFR 1119.4 - Factors considered in determining civil penalties.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... penalties. 1119.4 Section 1119.4 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION CONSUMER PRODUCT SAFETY ACT REGULATIONS CIVIL PENALTY FACTORS § 1119.4 Factors considered in determining civil penalties...) of the FFA, specify factors considered by the Commission in determining the amount of a civil penalty...

  11. 16 CFR 1119.4 - Factors considered in determining civil penalties.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... penalties. 1119.4 Section 1119.4 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION CONSUMER PRODUCT SAFETY ACT REGULATIONS CIVIL PENALTY FACTORS § 1119.4 Factors considered in determining civil penalties...) of the FFA, specify factors considered by the Commission in determining the amount of a civil penalty...

  12. 16 CFR 1119.4 - Factors considered in determining civil penalties.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... penalties. 1119.4 Section 1119.4 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION CONSUMER PRODUCT SAFETY ACT REGULATIONS CIVIL PENALTY FACTORS § 1119.4 Factors considered in determining civil penalties...) of the FFA, specify factors considered by the Commission in determining the amount of a civil penalty...

  13. Resting state cortico-cerebellar functional connectivity networks: a comparison of anatomical and self-organizing map approaches

    PubMed Central

    Bernard, Jessica A.; Seidler, Rachael D.; Hassevoort, Kelsey M.; Benson, Bryan L.; Welsh, Robert C.; Wiggins, Jillian Lee; Jaeggi, Susanne M.; Buschkuehl, Martin; Monk, Christopher S.; Jonides, John; Peltier, Scott J.

    2012-01-01

    The cerebellum plays a role in a wide variety of complex behaviors. In order to better understand the role of the cerebellum in human behavior, it is important to know how this structure interacts with cortical and other subcortical regions of the brain. To date, several studies have investigated the cerebellum using resting-state functional connectivity magnetic resonance imaging (fcMRI; Krienen and Buckner, 2009; O'Reilly et al., 2010; Buckner et al., 2011). However, none of this work has taken an anatomically-driven lobular approach. Furthermore, though detailed maps of cerebral cortex and cerebellum networks have been proposed using different network solutions based on the cerebral cortex (Buckner et al., 2011), it remains unknown whether or not an anatomical lobular breakdown best encompasses the networks of the cerebellum. Here, we used fcMRI to create an anatomically-driven connectivity atlas of the cerebellar lobules. Timecourses were extracted from the lobules of the right hemisphere and vermis. We found distinct networks for the individual lobules with a clear division into “motor” and “non-motor” regions. We also used a self-organizing map (SOM) algorithm to parcellate the cerebellum. This allowed us to investigate redundancy and independence of the anatomically identified cerebellar networks. We found that while anatomical boundaries in the anterior cerebellum provide functional subdivisions of a larger motor grouping defined using our SOM algorithm, in the posterior cerebellum, the lobules were made up of sub-regions associated with distinct functional networks. Together, our results indicate that the lobular boundaries of the human cerebellum are not necessarily indicative of functional boundaries, though anatomical divisions can be useful. Additionally, driving the analyses from the cerebellum is key to determining the complete picture of functional connectivity within the structure. PMID:22907994

  14. 16 CFR Figure 1 to Part 1203 - Anatomical Planes

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Anatomical Planes 1 Figure 1 to Part 1203 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION CONSUMER PRODUCT SAFETY ACT REGULATIONS SAFETY STANDARD FOR BICYCLE HELMETS Pt. 1203, Fig. 1 Figure 1 to Part 1203—Anatomical Planes ER10MR98.001 ...

  15. Feature-Based Morphometry: Discovering Group-related Anatomical Patterns

    PubMed Central

    Toews, Matthew; Wells, William; Collins, D. Louis; Arbel, Tal

    2015-01-01

    This paper presents feature-based morphometry (FBM), a new, fully data-driven technique for discovering patterns of group-related anatomical structure in volumetric imagery. In contrast to most morphometry methods which assume one-to-one correspondence between subjects, FBM explicitly aims to identify distinctive anatomical patterns that may only be present in subsets of subjects, due to disease or anatomical variability. The image is modeled as a collage of generic, localized image features that need not be present in all subjects. Scale-space theory is applied to analyze image features at the characteristic scale of underlying anatomical structures, instead of at arbitrary scales such as global or voxel-level. A probabilistic model describes features in terms of their appearance, geometry, and relationship to subject groups, and is automatically learned from a set of subject images and group labels. Features resulting from learning correspond to group-related anatomical structures that can potentially be used as image biomarkers of disease or as a basis for computer-aided diagnosis. The relationship between features and groups is quantified by the likelihood of feature occurrence within a specific group vs. the rest of the population, and feature significance is quantified in terms of the false discovery rate. Experiments validate FBM clinically in the analysis of normal (NC) and Alzheimer's (AD) brain images using the freely available OASIS database. FBM automatically identifies known structural differences between NC and AD subjects in a fully data-driven fashion, and an equal error classification rate of 0.80 is achieved for subjects aged 60-80 years exhibiting mild AD (CDR=1). PMID:19853047

  16. Effect of Anatomical and Developmental Factors on the Risk of Unplanned Extubation in Critically Ill Newborns

    PubMed Central

    Hatch, L. Dupree; Grubb, Peter H.; Markham, Melinda H.; Scott, Theresa A.; Walsh, William F.; Slaughter, James C.; Stark, Ann R.; Ely, E. Wesley

    2017-01-01

    Objective To quantify the daily risk of unplanned extubation (UE) in newborns based on developmental and anatomical factors. Methods Prospective cohort of ventilated newborns over an 18-month period in a level IV neonatal intensive care unit (NICU). We captured UEs through four data streams. We generated multivariable logistic regression models to assess the association of UE with chronological age, birth weight, and postmenstrual age. Results During the study, 718 infants were ventilated for 5,611 patient days with 117 UEs in 81 infants. The daily risk of UE had a significant, nonlinear relationship (p < 0.01) with chronological age, decreasing until day 7 (odds ratio [OR]: 0.5; 95% confidence interval [CI]: 0.17–1.47) and increasing after day 7 (day 7–28, OR: 1.36, 95% CI: 1.06–1.75; and >28 days, OR: 1.06, 95% CI: 1.0–1.14). Birth weight and postmenstrual age were not associated with UE. Adverse events occurred in 83/117 (71%) UE events. Iatrogenic causes of UE were more common in younger, smaller infants, whereas older, larger infants were more likely to self-extubate. Conclusion The daily risk and causes of UE change over the course of an infant’s NICU hospitalization. These data can be used to identify infants at the highest risk of UE for whom targeted proactive interventions can be developed. PMID:28494497

  17. Which Tibial Tray Design Achieves Maximum Coverage and Ideal Rotation: Anatomic, Symmetric, or Asymmetric? An MRI-based study.

    PubMed

    Stulberg, S David; Goyal, Nitin

    2015-10-01

    Two goals of tibial tray placement in TKA are to maximize coverage and establish proper rotation. Our purpose was to utilize MRI information obtained as part of PSI planning to determine the impact of tibial tray design on the relationship between coverage and rotation. MR images for 100 consecutive knees were uploaded into PSI software. Preoperative planning software was used to evaluate 3 different tray designs: anatomic, symmetric, and asymmetric. Approximately equally good coverage was achieved with all three trays. However, the anatomic compared to symmetric/asymmetric trays required less malrotation (0.3° vs 3.0/2.4°; P < 0.001), with a higher proportion of cases within 5° of neutral (97% vs 73/77%; P < 0.001). In this study, the anatomic tibia optimized the relationship between coverage and rotation. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. An Investigation of Anatomical Competence in Junior Medical Doctors

    ERIC Educational Resources Information Center

    Vorstenbosch, Marc A. T. M.; Kooloos, Jan G. M.; Bolhuis, Sanneke M.; Laan, Roland F. J. M.

    2016-01-01

    Because of a decrease of the time available for anatomy education, decisions need to be made to reduce the relevant content of the anatomy curriculum. Several expert consensus initiatives resulted in lists of structures, lacking analysis of anatomical competence. This study aims to explore the use of anatomical knowledge by medical doctors in an…

  19. [Lymphoscintigrams with anatomical landmarks obtained with vector graphics].

    PubMed

    Rubini, Giuseppe; Antonica, Filippo; Renna, Maria Antonia; Ferrari, Cristina; Iuele, Francesca; Stabile Ianora, Antonio Amato; Losco, Matteo; Niccoli Asabella, Artor

    2012-11-01

    Nuclear medicine images are difficult to interpret because they do not include anatomical details. The aim of this study was to obtain lymphoscintigrams with anatomical landmarks that could be easily interpreted by General Physicians. Traditional lymphoscintigrams were processed with Adobe© Photoshop® CS6 and converted into vector images created by Illustrator®. The combination with a silhouette vector improved image interpretation, without resulting in longer radiation exposure or acquisition times.

  20. The Intermingled History of Occupational Therapy and Anatomical Education: A Retrospective Exploration

    ERIC Educational Resources Information Center

    Carroll, Melissa A.; Lawson, Katherine

    2014-01-01

    Few research articles have addressed the anatomical needs of entry-level occupational therapy students. Given this paucity of empirical evidence, there is a lack of knowledge regarding anatomical education in occupational therapy. This article will primarily serve as a retrospective look at the inclusion of anatomical education in the occupational…

  1. Complex vestibular macular anatomical relationships need a synthetic approach

    NASA Technical Reports Server (NTRS)

    Ross, M. D.

    2001-01-01

    Mammalian vestibular maculae are anatomically organized for complex parallel processing of linear acceleration information. Anatomical findings in rat maculae are provided in order to underscore this complexity, which is little understood functionally. This report emphasizes that a synthetic approach is critical to understanding how maculae function and the kind of information they conduct to the brain.

  2. Reproducibility Between Brain Uptake Ratio Using Anatomic Standardization and Patlak-Plot Methods.

    PubMed

    Shibutani, Takayuki; Onoguchi, Masahisa; Noguchi, Atsushi; Yamada, Tomoki; Tsuchihashi, Hiroko; Nakajima, Tadashi; Kinuya, Seigo

    2015-12-01

    The Patlak-plot and conventional methods of determining brain uptake ratio (BUR) have some problems with reproducibility. We formulated a method of determining BUR using anatomic standardization (BUR-AS) in a statistical parametric mapping algorithm to improve reproducibility. The objective of this study was to demonstrate the inter- and intraoperator reproducibility of mean cerebral blood flow as determined using BUR-AS in comparison to the conventional-BUR (BUR-C) and Patlak-plot methods. The images of 30 patients who underwent brain perfusion SPECT were retrospectively used in this study. The images were reconstructed using ordered-subset expectation maximization and processed using an automatic quantitative analysis for cerebral blood flow of ECD tool. The mean SPECT count was calculated from axial basal ganglia slices of the normal side (slices 31-40) drawn using a 3-dimensional stereotactic region-of-interest template after anatomic standardization. The mean cerebral blood flow was calculated from the mean SPECT count. Reproducibility was evaluated using coefficient of variation and Bland-Altman plotting. For both inter- and intraoperator reproducibility, the BUR-AS method had the lowest coefficient of variation and smallest error range about the Bland-Altman plot. Mean CBF obtained using the BUR-AS method had the highest reproducibility. Compared with the Patlak-plot and BUR-C methods, the BUR-AS method provides greater inter- and intraoperator reproducibility of cerebral blood flow measurement. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  3. Frequency in Usage of FCAT-Approved Anatomical Terms by North American Anatomists

    ERIC Educational Resources Information Center

    Martin, Bradford D.; Thorpe, Donna; Barnes, Richard; DeLeon, Michael; Hill, Douglas

    2009-01-01

    It has been 10 years since the Federative Committee on Anatomical Terminology (FCAT) published Terminologia Anatomica (TA), the current authority on anatomical nomenclature. There exists a perceived lack of unity among anatomists to adopt many FCAT recommended anatomical terms in TA. An e-mail survey was sent to members of the American Association…

  4. Gross anatomical and dimensional characteristics of the proximal hamstring origin.

    PubMed

    Feucht, Matthias J; Plath, Johannes E; Seppel, Gernot; Hinterwimmer, Stefan; Imhoff, Andreas B; Brucker, Peter U

    2015-09-01

    The current study was undertaken to better define the gross anatomical and dimensional characteristics of the proximal hamstring origin. Twelve paired whole-lower extremities from six embalmed cadavers were dissected. The gross anatomy of the proximal hamstrings was studied. With the tendons attached to the ischial tuberosity, the width and thickness of each tendon was measured 1 cm distally to their origin, and the distance from the most proximal border of the common origin of the semitendinosus (ST) and long head of the biceps (LB) to their distal junction was assessed. After removal of the hamstring group, the shape, orientation, and dimension of the tendon footprints were determined. One cadaver demonstrated unique anatomy, which was considered as an anatomic variant and was therefore excluded from the study group. The ST and LB had a common origin on the posterolateral aspect of the ischial tuberosity (ST/LB), whereas the semimembranosus (SM) had a separated origin at the anterolateral aspect. The mean distance from the most proximal border of the ST/LB origin to the distal junction was 10.0 ± 1.3 cm. The shape of both footprints was longitudinal-oval, with the longitudinal axes of the SM and ST/LB footprints parallel aligned. Mean tendon width was 3.4 ± 0.5 cm for the common ST/LB complex and 4.2 ± 0.9 cm for the SM (p = 0.009). The corresponding values for tendon thickness were 1.0 ± 0.3 cm (ST/LB) and 0.8 ± 0.2 cm (SM), respectively (n.s.). Mean footprint length was 3.9 ± 0.4 cm for ST/LB and 4.5 ± 0.5 cm for SM (p = 0.002). The corresponding values for footprint height were 1.4 ± 0.5 cm (ST/LB) and 1.2 ± 0.3 cm (SM), respectively (n.s.). The ST and LB had a common origin, whereas the SM originated separately. The site of origin of both tendons was the lateral aspect of the ischial tuberosity, with the SM footprint lying directly anterior to the footprint of the ST/LB complex. The footprint of the SM was significantly wider than the footprint of

  5. The Computerized Anatomical Man (CAM) model

    NASA Technical Reports Server (NTRS)

    Billings, M. P.; Yucker, W. R.

    1973-01-01

    A computerized anatomical man (CAM) model, representing the most detailed and anatomically correct geometrical model of the human body yet prepared, has been developed for use in analyzing radiation dose distribution in man. This model of a 50-percentile standing USAF man comprises some 1100 unique geometric surfaces and some 2450 solid regions. Internal body geometry such as organs, voids, bones, and bone marrow are explicitly modeled. A computer program called CAMERA has also been developed for performing analyses with the model. Such analyses include tracing rays through the CAM geometry, placing results on magnetic tape in various forms, collapsing areal density data from ray tracing information to areal density distributions, preparing cross section views, etc. Numerous computer drawn cross sections through the CAM model are presented.

  6. The anatomic basis of lingual nerve trauma associated with inferior alveolar block injections.

    PubMed

    Morris, Christopher D; Rasmussen, Jared; Throckmorton, Gaylord S; Finn, Richard

    2010-11-01

    This study describes the anatomic variability in the position of the lingual nerve in the pterygomandibular space, the location of the inferior alveolar nerve block injection. Simulated standard landmark-based inferior alveolar nerve blocks were administered to 44 fixed sagitally bisected cadaver heads. Measurements were made of the diameter of the nerves and distances between the needle and selected anatomic landmarks and the nerves. Of 44 simulated injections, 42 (95.5%) passed lateral to the lingual nerve, 7 (16%) passed within 0.1 mm of the nerve, and 2 (4.5%) penetrated the nerve. The position of the lingual nerve relative to bony landmarks within the interpterygoid fascia was highly variable. Variation in the position of the lingual nerve is an important contributor to lingual nerve trauma during inferior alveolar block injections. This factor should be an important part of preoperative informed consent. Copyright © 2010 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  7. The intermingled history of occupational therapy and anatomical education: A retrospective exploration.

    PubMed

    Carroll, Melissa A; Lawson, Katherine

    2014-01-01

    Few research articles have addressed the anatomical needs of entry-level occupational therapy students. Given this paucity of empirical evidence, there is a lack of knowledge regarding anatomical education in occupational therapy. This article will primarily serve as a retrospective look at the inclusion of anatomical education in the occupational therapy curriculum. Focusing on the historical inclusion is the first step to address the gap in existing knowledge. Examining the history of anatomy in occupational therapy provides an educational context for curricular developments and helps current anatomical educators understand the evolution of occupational therapy as a profession. Exploring the educational history also offers anatomy educators an identity, as significant contributors, in the training and preparedness of entry-level professionals while focusing on the ideals of occupational therapy. However, there is a critical need for empirical evidence of best teaching practices in occupational therapy and anatomical education. This manuscript provides a foundation and a starting point for further investigation into the anatomical competencies for entry-level occupational therapists. © 2014 American Association of Anatomists.

  8. The Anatomical Computer (CD-ROM).

    ERIC Educational Resources Information Center

    Duhrkopf, Richard

    1996-01-01

    Describes the Anatomical Computer (CD-ROM) that was designed as a self-study aid for undergraduate and graduate students in anatomy. Provides text with illustrations, definitions along with summary charts, and more than a thousand test questions. Provides a valuable resource for human gross anatomy review. (JRH)

  9. Evaluation of 3D printed anatomically scalable transfemoral prosthetic knee.

    PubMed

    Ramakrishnan, Tyagi; Schlafly, Millicent; Reed, Kyle B

    2017-07-01

    This case study compares a transfemoral amputee's gait while using the existing Ossur Total Knee 2000 and our novel 3D printed anatomically scalable transfemoral prosthetic knee. The anatomically scalable transfemoral prosthetic knee is 3D printed out of a carbon-fiber and nylon composite that has a gear-mesh coupling with a hard-stop weight-actuated locking mechanism aided by a cross-linked four-bar spring mechanism. This design can be scaled using anatomical dimensions of a human femur and tibia to have a unique fit for each user. The transfemoral amputee who was tested is high functioning and walked on the Computer Assisted Rehabilitation Environment (CAREN) at a self-selected pace. The motion capture and force data that was collected showed that there were distinct differences in the gait dynamics. The data was used to perform the Combined Gait Asymmetry Metric (CGAM), where the scores revealed that the overall asymmetry of the gait on the Ossur Total Knee was more asymmetric than the anatomically scalable transfemoral prosthetic knee. The anatomically scalable transfemoral prosthetic knee had higher peak knee flexion that caused a large step time asymmetry. This made walking on the anatomically scalable transfemoral prosthetic knee more strenuous due to the compensatory movements in adapting to the different dynamics. This can be overcome by tuning the cross-linked spring mechanism to emulate the dynamics of the subject better. The subject stated that the knee would be good for daily use and has the potential to be adapted as a running knee.

  10. CT of Anatomic Variants of the Paranasal Sinuses and Nasal Cavity: Poor Correlation With Radiologically Significant Rhinosinusitis but Importance in Surgical Planning.

    PubMed

    Shpilberg, Katya A; Daniel, Simon C; Doshi, Amish H; Lawson, William; Som, Peter M

    2015-06-01

    The purpose of this study was to determine the incidence of sinonasal anatomic variants and to assess their relation to sinonasal mucosal disease. A retrospective evaluation of 192 sinus CT examinations of patients with a clinical history of rhinosinusitis was conducted. The CT scans were evaluated for the presence of several anatomic variants of the sinonasal cavities, and the prevalence of each variant was calculated. Prevalences of all sinonasal anatomic variants were compared between patients who had minimal to no apparent imaging evidence of rhinosinusitis and those who had radiologic evidence of clinically significant rhinosinusitis. The most common normal variants were nasal septal deviation, Agger nasi cells, and extension of the sphenoid sinuses into the posterior nasal septum. We found no statistically significant difference in the prevalence of any of the studied anatomic variants between patients with minimal and those with clinically significant paranasal sinus or nasal cavity disease. Analysis of every routine CT scan of the paranasal sinuses obtained for sinusitis or rhinitis for the presence of different anatomic variants is of questionable value unless surgery is planned.

  11. Optimization of abdominal fat quantification on CT imaging through use of standardized anatomic space: A novel approach

    PubMed Central

    Tong, Yubing; Udupa, Jayaram K.; Torigian, Drew A.

    2014-01-01

    Purpose: The quantification of body fat plays an important role in the study of numerous diseases. It is common current practice to use the fat area at a single abdominal computed tomography (CT) slice as a marker of the body fat content in studying various disease processes. This paper sets out to answer three questions related to this issue which have not been addressed in the literature. At what single anatomic slice location do the areas of subcutaneous adipose tissue (SAT) and visceral adipose tissue (VAT) estimated from the slice correlate maximally with the corresponding fat volume measures? How does one ensure that the slices used for correlation calculation from different subjects are at the same anatomic location? Are there combinations of multiple slices (not necessarily contiguous) whose area sum correlates better with volume than does single slice area with volume? Methods: The authors propose a novel strategy for mapping slice locations to a standardized anatomic space so that same anatomic slice locations are identified in different subjects. The authors then study the volume-to-area correlations and determine where they become maximal. To address the third issue, the authors carry out similar correlation studies by utilizing two and three slices for calculating area sum. Results: Based on 50 abdominal CT data sets, the proposed mapping achieves significantly improved consistency of anatomic localization compared to current practice. Maximum correlations are achieved at different anatomic locations for SAT and VAT which are both different from the L4-L5 junction commonly utilized currently for single slice area estimation as a marker. Conclusions: The maximum area-to-volume correlation achieved is quite high, suggesting that it may be reasonable to estimate body fat by measuring the area of fat from a single anatomic slice at the site of maximum correlation and use this as a marker. The site of maximum correlation is not at L4-L5 as commonly assumed

  12. Optimization of abdominal fat quantification on CT imaging through use of standardized anatomic space: A novel approach

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tong, Yubing; Udupa, Jayaram K., E-mail: jay@mail.med.upenn.edu; Torigian, Drew A.

    Purpose: The quantification of body fat plays an important role in the study of numerous diseases. It is common current practice to use the fat area at a single abdominal computed tomography (CT) slice as a marker of the body fat content in studying various disease processes. This paper sets out to answer three questions related to this issue which have not been addressed in the literature. At what single anatomic slice location do the areas of subcutaneous adipose tissue (SAT) and visceral adipose tissue (VAT) estimated from the slice correlate maximally with the corresponding fat volume measures? How doesmore » one ensure that the slices used for correlation calculation from different subjects are at the same anatomic location? Are there combinations of multiple slices (not necessarily contiguous) whose area sum correlates better with volume than does single slice area with volume? Methods: The authors propose a novel strategy for mapping slice locations to a standardized anatomic space so that same anatomic slice locations are identified in different subjects. The authors then study the volume-to-area correlations and determine where they become maximal. To address the third issue, the authors carry out similar correlation studies by utilizing two and three slices for calculating area sum. Results: Based on 50 abdominal CT data sets, the proposed mapping achieves significantly improved consistency of anatomic localization compared to current practice. Maximum correlations are achieved at different anatomic locations for SAT and VAT which are both different from the L4-L5 junction commonly utilized currently for single slice area estimation as a marker. Conclusions: The maximum area-to-volume correlation achieved is quite high, suggesting that it may be reasonable to estimate body fat by measuring the area of fat from a single anatomic slice at the site of maximum correlation and use this as a marker. The site of maximum correlation is not at L4-L5 as commonly

  13. Anatomical image-guided fluorescence molecular tomography reconstruction using kernel method

    NASA Astrophysics Data System (ADS)

    Baikejiang, Reheman; Zhao, Yue; Fite, Brett Z.; Ferrara, Katherine W.; Li, Changqing

    2017-05-01

    Fluorescence molecular tomography (FMT) is an important in vivo imaging modality to visualize physiological and pathological processes in small animals. However, FMT reconstruction is ill-posed and ill-conditioned due to strong optical scattering in deep tissues, which results in poor spatial resolution. It is well known that FMT image quality can be improved substantially by applying the structural guidance in the FMT reconstruction. An approach to introducing anatomical information into the FMT reconstruction is presented using the kernel method. In contrast to conventional methods that incorporate anatomical information with a Laplacian-type regularization matrix, the proposed method introduces the anatomical guidance into the projection model of FMT. The primary advantage of the proposed method is that it does not require segmentation of targets in the anatomical images. Numerical simulations and phantom experiments have been performed to demonstrate the proposed approach's feasibility. Numerical simulation results indicate that the proposed kernel method can separate two FMT targets with an edge-to-edge distance of 1 mm and is robust to false-positive guidance and inhomogeneity in the anatomical image. For the phantom experiments with two FMT targets, the kernel method has reconstructed both targets successfully, which further validates the proposed kernel method.

  14. Anatomical image-guided fluorescence molecular tomography reconstruction using kernel method

    PubMed Central

    Baikejiang, Reheman; Zhao, Yue; Fite, Brett Z.; Ferrara, Katherine W.; Li, Changqing

    2017-01-01

    Abstract. Fluorescence molecular tomography (FMT) is an important in vivo imaging modality to visualize physiological and pathological processes in small animals. However, FMT reconstruction is ill-posed and ill-conditioned due to strong optical scattering in deep tissues, which results in poor spatial resolution. It is well known that FMT image quality can be improved substantially by applying the structural guidance in the FMT reconstruction. An approach to introducing anatomical information into the FMT reconstruction is presented using the kernel method. In contrast to conventional methods that incorporate anatomical information with a Laplacian-type regularization matrix, the proposed method introduces the anatomical guidance into the projection model of FMT. The primary advantage of the proposed method is that it does not require segmentation of targets in the anatomical images. Numerical simulations and phantom experiments have been performed to demonstrate the proposed approach’s feasibility. Numerical simulation results indicate that the proposed kernel method can separate two FMT targets with an edge-to-edge distance of 1 mm and is robust to false-positive guidance and inhomogeneity in the anatomical image. For the phantom experiments with two FMT targets, the kernel method has reconstructed both targets successfully, which further validates the proposed kernel method. PMID:28464120

  15. Development of local complexity metrics to quantify the effect of anatomical noise on detectability of lung nodules in chest CT imaging

    NASA Astrophysics Data System (ADS)

    Solomon, Justin; Rubin, Geoffrey; Smith, Taylor; Harrawood, Brian; Choudhury, Kingshuk Roy; Samei, Ehsan

    2017-03-01

    The purpose of this study was to develop metrics of local anatomical complexity and compare them with detectability of lung nodules in CT. Data were drawn retrospectively from a published perception experiment in which detectability was assessed in cases enriched with virtual nodules (13 radiologists x 157 total nodules = 2041 responses). A local anatomical complexity metric called the distractor index was developed, defined as the Gaussian weighted proportion (i.e., average) of distracting local voxels (50 voxels in-plane, 5 slices). A distracting voxel was classified by thresholding image data that had been selectively filtered to enhance nodule-like features. The distractor index was measured for each nodule location in the nodule-free images. The local pixel standard deviation (STD) was also measured for each nodule. Other confounding factors of search fraction (proportion of lung voxels to total voxels in the given slice) and peripheral distance (defined as the 3D distance of the nodule from the trachea bifurcation) were measured. A generalized linear mixed-effects statistical model (no interaction terms, probit link function, random reader term) was fit to the data to determine the influence of each metric on detectability. In order of decreasing effect size: distractor index, STD, and search fraction all significantly affected detectability (P < 0.001). Distance to the trachea did not have a significant effect (P < 0.05). These data demonstrate that local lung complexity degrades detection of lung nodules and the distractor index could serve as a good surrogate metric to quantify anatomical complexity.

  16. Deep sleep divides the cortex into opposite modes of anatomical-functional coupling.

    PubMed

    Tagliazucchi, Enzo; Crossley, Nicolas; Bullmore, Edward T; Laufs, Helmut

    2016-11-01

    The coupling of anatomical and functional connectivity at rest suggests that anatomy is essential for wake-typical activity patterns. Here, we study the development of this coupling from wakefulness to deep sleep. Globally, similarity between whole-brain anatomical and functional connectivity networks increased during deep sleep. Regionally, we found differential coupling: during sleep, functional connectivity of primary cortices resembled more the underlying anatomical connectivity, while we observed the opposite in associative cortices. Increased anatomical-functional similarity in sensory areas is consistent with their stereotypical, cross-modal response to the environment during sleep. In distinction, looser coupling-relative to wakeful rest-in higher order integrative cortices suggests that sleep actively disrupts default patterns of functional connectivity in regions essential for the conscious access of information and that anatomical connectivity acts as an anchor for the restoration of their functionality upon awakening.

  17. Anatomical, chemical, and ecological factors affecting tree species choice in dendrochemistry studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cutter, B.E.; Guyette, R.P.

    1993-07-01

    Recently, element concentrations in tree rings have been used to monitor metal contamination, fertilization, and the effects of acid precipitation on soils. This has stimulated interest in which tree species may be suitable for use in studies of long-term trends in environmental chemistry. Potential radial translocation of elements across living boundaries can be a confounding factor in assessing environmental change. The selection of species which minimizes radial translocation of elements can be critical to the success of dendrochemical research. Criteria for selection of species with characteristics favorable for dendrochemical analysis are categorized into (1) habitat-based factors, (2) xylem-based factors, andmore » (3) element-based factors. A wide geographic range and ecological amplitude provide an advantage in calibration and better controls on the effects of soil chemistry. The most important xylem-based criteria are heartwood moisture content, permeability, and the nature of the sapwood-heartwood transition. The element of interest is important in determining suitable tree species because all elements are not equally mobile or detectable in the xylem. Ideally, the tree species selected for dendrochemical study will be long-lived, grow on a wide range of sites over a large geographic distribution, have a distinct heartwood with a low number of rings in the sapwood, a low heartwood moisture content, and have low radial permeability. Recommended temperate zone North American species include white oak (Quercus alba L.), post oak (Q. stellate Wangenh.), eastern redcedar (funiperus virginiana L.), old-growth Douglas-fir [Pseudoaugu menziesii (Mirb.) Franco] and big sagebrush (Artemisia tridentata Nutt.). In addition, species such as bristlecone pine (Pinus aristata Engelm. syn. longaeva), old-growth redwood [Sequoia sempervirens (D. Don) Endl.], and giant sequoia [S. gigantea (Lindl.) Deene] may be suitable for local purposes. 118 refs., 2 tabs.« less

  18. An anatomical and histological study of the structures surrounding the proximal attachment of the hamstring muscles.

    PubMed

    Pérez-Bellmunt, Albert; Miguel-Pérez, Maribel; Brugué, Marc Blasi; Cabús, Juan Blasi; Casals, Martí; Martinoli, Carlo; Kuisma, Raija

    2015-06-01

    The proximal attachment of hamstring muscles has a very high incidence of injuries due to a wide number of factors and its morphology may be one of the underlying factors as scientific literature points out. The connective tissue component of the attachment of hamstring muscles is not well known. For this reason the aim of this study is to describe the anatomy and histology surrounding the proximal attachment of the hamstring muscles (PAHM) and its direct anatomic relations. Forty-eight cryopreserved lower limbs have sequentially been studied by means of dissection, anatomical sections and histology. All specimens studied presented an annular connective tissue structure that resembles a retinaculum, which covers and adapts to the attachment of hamstring muscles on the ischial tuberosity. The results show how this retinaculum is continuous with the long head of biceps femoris muscle, however there is a layer of loose connective tissue between the retinaculum and the semitendinosus muscle. Furthermore, this structure receives expansions of the anterior epimysium of the gluteus maximus muscle (GIM). Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. [The anatomical revolution and the transition of anatomical conception in late imperial china].

    PubMed

    Sihn, Kyu Hwan

    2012-04-30

    This paper aimed to examine the anatomical revolution from Yilingaicuo (Correcting the Errors of Medicine) and Quantixinlun(Outline of Anatomy and Physiology) in late imperial China. As the cephalocentrism which the brain superintend human operation of the mind was diffused in China since 16th century, the cephalocentrism and the cardiocentrism had competed for the hegemony of anatomical conception. Because of the advent of Yilingaicuo and Quantixinlun, the cephalocentrism became the main stream in the anatomical conception. The supporters of the Wang Yangming's Xinxue(the Learning of Heart and Mind) argued that the heart was the central organ of perception, sensitivity, and morality of the human body in medicine since 16th century. Even reformist and revolutionary intellectuals like Tan sitong and Mao zedong who had supported the Wang Yangming's Xinxue embraced the cephalocentrism in the late 19th century and the early 20th century. May Fourth intellectuals had not obsessed metaphysical interpretation of human body any more in the New Culture Movement in 1910s. They regarded human body as the object of research and writing. The anatomy was transformed into the instrumental knowledge for mutilation of the body. Yilingaicuo challenged the traditional conception of body, and Chinese intellectuals drew interest in the anatomy knowledge based on real mutilation. Quantixinlun based on Western medicine fueled a controversy about anatomy. Though new knowledge of anatomy was criticized by traditional Chinese medical doctors from the usefulness and morality of anatomy, nobody disavowed new knowledge of anatomy from the institutionalization of Western medicine in medical school. The internal development of cephalocentrism and positivism had influence on anatomy in China since 16th century. The advent of Yilingaicuo and Quantixinlun provided the milestone of new anatomy, though both sides represented traditional Chinese medicine and Western medicine respectively. They

  20. Psychosocial Factors and Musculoskeletal Pain Among Rural Hand-woven Carpet Weavers in Iran

    PubMed Central

    Chaman, Reza; Aliyari, Roqayeh; Sadeghian, Farideh; Vatani Shoaa, Javad; Masoudi, Mahmood; Zahedi, Shiva; Bakhshi, Mohammad A.

    2015-01-01

    Background Musculoskeletal pain (MSP) is a common and disabling problem among carpet weavers and is linked to physical and psychosocial factors of work. This study aimed to determine the prevalence of MSP, its psychosocial risk factors, and association of pain in each pair of anatomical sites among carpet weavers. Methods A cross-sectional study was performed among 546 hand-woven carpet weavers in rural small-scale workshops of Iran. Data were collected by using parts of a standardized CUPID (Cultural and Psychosocial Influences on Disability) questionnaire focused on MSP in 10 body sites, including the low-back, neck, both right and left shoulders, elbows, wrists/hands, individual, physical and psychosocial risk factors. Statistical analysis was performed applying logistic regression models. Results Prevalence of MSP in at least one body site was 51.7% over the past month. The most common sites were low back and right shoulder pain 27.4% and 20.1%, respectively. A significant difference was found between the mean number of painful anatomical sites and the level of education, age, physical loading at work, time pressure, lack of support, and job dissatisfaction. In pairwise comparisons, strongest association was found between pain in each bilateral anatomical site (odds ratio = 11.6–35.3; p < 0.001). Conclusion In home-based workshops of carpet weaving, psychosocial factors and physical loading were associated with MSP. This finding is consistent with studies conducted among other jobs. Considering the preventive programs, the same amount of attention should be paid to psychosocial risk factors and physical loading. Also, further longitudinal studies are needed to investigate the relationship of psychological factors. PMID:26106511

  1. Bayesian reconstruction and use of anatomical a priori information for emission tomography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bowsher, J.E.; Johnson, V.E.; Turkington, T.G.

    1996-10-01

    A Bayesian method is presented for simultaneously segmenting and reconstructing emission computed tomography (ECT) images and for incorporating high-resolution, anatomical information into those reconstructions. The anatomical information is often available from other imaging modalities such as computed tomography (CT) or magnetic resonance imaging (MRI). The Bayesian procedure models the ECT radiopharmaceutical distribution as consisting of regions, such that radiopharmaceutical activity is similar throughout each region. It estimates the number of regions, the mean activity of each region, and the region classification and mean activity of each voxel. Anatomical information is incorporated by assigning higher prior probabilities to ECT segmentations inmore » which each ECT region stays within a single anatomical region. This approach is effective because anatomical tissue type often strongly influences radiopharmaceutical uptake. The Bayesian procedure is evaluated using physically acquired single-photon emission computed tomography (SPECT) projection data and MRI for the three-dimensional (3-D) Hoffman brain phantom. A clinically realistic count level is used. A cold lesion within the brain phantom is created during the SPECT scan but not during the MRI to demonstrate that the estimation procedure can detect ECT structure that is not present anatomically.« less

  2. TU-F-CAMPUS-I-01: Investigation of the Effective Dose From Bolus Tracking Acquisitions at Different Anatomical Locations in the Chest for CT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nowik, P; Bujila, R; Merzan, D

    2015-06-15

    Purpose: Stationary table acquisitions (Bolus tracking) in X-ray Computed Tomography (CT) can Result in dose length products (DLP) comparable to spiral scans. It is today unclear whether or not the effective dose (E) for Bolus Tracking can be approximated using target region specific conversion factors (E/DLP). The purpose of this study was to investigate how E depends on the anatomical location of the Bolus Tracking in relation to Chest CT scans with the same DLP. Methods: Effective doses were approximated for the ICRP 110 adult Reference Male (AM) and adult Reference Female (FM) computational voxel phantoms using software for CTmore » dose approximations (pre-simulated MC data). The effective dose was first approximated for a Chest CT scan using spiral technique and a CTDIvol (32 cm) of 6 mGy. The effective dose from the spiral scan was then compared to E approximated for contiguous Bolus Tracking acquisitions (1 cm separation), with a total collimation of 1 cm, over different locations of the chest of the voxel phantoms. The number of rotations used for the Bolus Tracking acquisitions was adjusted to yield the same DLP (32 cm) as the spiral scan. Results: Depending on the anatomical location of the Bolus Tracking, E ranged by factors of 1.3 to 6.8 for the AM phantom and 1.4 to 3.3 for the AF phantom, compared to the effective dose of the spiral scans. The greatest E for the Bolus Tracking acquisitions was observed for anatomical locations coinciding with breast tissue. This can be expected as breast tissue has a high tissue weighting factor in the calculation of E. Conclusion: For Chest CT scans, the effective dose from Bolus Tracking is highly dependent on the anatomical location where the scan is administered and will not always accurately be represented using target region specific conversion factors.« less

  3. Intraspecific Variation in Wood Anatomical, Hydraulic, and Foliar Traits in Ten European Beech Provenances Differing in Growth Yield

    PubMed Central

    Hajek, Peter; Kurjak, Daniel; von Wühlisch, Georg; Delzon, Sylvain; Schuldt, Bernhard

    2016-01-01

    In angiosperms, many studies have described the inter-specific variability of hydraulic-related traits and little is known at the intra-specific level. This information is however mandatory to assess the adaptive capacities of tree populations in the context of increasing drought frequency and severity. Ten 20-year old European beech (Fagus sylvatica L.) provenances representing the entire distribution range throughout Europe and differing significantly in aboveground biomass increment (ABI) by a factor of up to four were investigated for branch wood anatomical, hydraulic, and foliar traits in a provenance trial located in Northern Europe. We quantified to which extend xylem hydraulic and leaf traits are under genetic control and tested whether the xylem hydraulic properties (hydraulic efficiency and safety) trades off with yield and wood anatomical and leaf traits. Our results showed that only three out of 22 investigated ecophysiological traits showed significant genetic differentiations between provenances, namely vessel density (VD), the xylem pressure causing 88% loss of hydraulic conductance and mean leaf size. Depending of the ecophysiological traits measured, genetic differentiation between populations explained 0–14% of total phenotypic variation, while intra-population variability was higher than inter-population variability. Most wood anatomical traits and some foliar traits were additionally related to the climate of provenance origin. The lumen to sapwood area ratio, vessel diameter, theoretical specific conductivity and theoretical leaf-specific conductivity as well as the C:N-ratio increased with climatic aridity at the place of origin while the carbon isotope signature (δ13C) decreased. Contrary to our assumption, none of the wood anatomical traits were related to embolism resistance but were strong determinants of hydraulic efficiency. Although ABI was associated with both VD and δ13C, both hydraulic efficiency and embolism resistance were

  4. Intraspecific Variation in Wood Anatomical, Hydraulic, and Foliar Traits in Ten European Beech Provenances Differing in Growth Yield.

    PubMed

    Hajek, Peter; Kurjak, Daniel; von Wühlisch, Georg; Delzon, Sylvain; Schuldt, Bernhard

    2016-01-01

    In angiosperms, many studies have described the inter-specific variability of hydraulic-related traits and little is known at the intra-specific level. This information is however mandatory to assess the adaptive capacities of tree populations in the context of increasing drought frequency and severity. Ten 20-year old European beech (Fagus sylvatica L.) provenances representing the entire distribution range throughout Europe and differing significantly in aboveground biomass increment (ABI) by a factor of up to four were investigated for branch wood anatomical, hydraulic, and foliar traits in a provenance trial located in Northern Europe. We quantified to which extend xylem hydraulic and leaf traits are under genetic control and tested whether the xylem hydraulic properties (hydraulic efficiency and safety) trades off with yield and wood anatomical and leaf traits. Our results showed that only three out of 22 investigated ecophysiological traits showed significant genetic differentiations between provenances, namely vessel density (VD), the xylem pressure causing 88% loss of hydraulic conductance and mean leaf size. Depending of the ecophysiological traits measured, genetic differentiation between populations explained 0-14% of total phenotypic variation, while intra-population variability was higher than inter-population variability. Most wood anatomical traits and some foliar traits were additionally related to the climate of provenance origin. The lumen to sapwood area ratio, vessel diameter, theoretical specific conductivity and theoretical leaf-specific conductivity as well as the C:N-ratio increased with climatic aridity at the place of origin while the carbon isotope signature (δ(13)C) decreased. Contrary to our assumption, none of the wood anatomical traits were related to embolism resistance but were strong determinants of hydraulic efficiency. Although ABI was associated with both VD and δ(13)C, both hydraulic efficiency and embolism resistance were

  5. Body shape transformation along a shared axis of anatomical evolution in labyrinth fishes (Anabantoidei).

    PubMed

    Collar, David C; Quintero, Michelle; Buttler, Bernardo; Ward, Andrea B; Mehta, Rita S

    2016-03-01

    Major morphological transformations, such as the evolution of elongate body shape in vertebrates, punctuate evolutionary history. A fundamental step in understanding the processes that give rise to such transformations is identification of the underlying anatomical changes. But as we demonstrate in this study, important insights can also be gained by comparing these changes to those that occur in ancestral and closely related lineages. In labyrinth fishes (Anabantoidei), rapid evolution of a highly derived torpedo-shaped body in the common ancestor of the pikehead (Luciocephalus aura and L. pulcher) occurred primarily through exceptional elongation of the head, with secondary contributions involving reduction in body depth and lengthening of the precaudal vertebral region. This combination of changes aligns closely with the primary axis of anatomical diversification in other anabantoids, revealing that pikehead evolution involved extraordinarily rapid change in structures that were ancestrally labile. Finer-scale examination of the anatomical components that determine head elongation also shows alignment between the pikehead evolutionary trajectory and the primary axis of cranial diversification in anabantoids, with much higher evolutionary rates leading to the pikehead. Altogether, our results show major morphological transformation stemming from extreme change along a shared morphological axis in labyrinth fishes. © 2016 The Author(s). Evolution © 2016 The Society for the Study of Evolution.

  6. Impact of anatomic characteristics and initial biventricular surgical strategy on outcomes in various forms of double-outlet right ventricle.

    PubMed

    Villemain, Olivier; Belli, Emre; Ladouceur, Magalie; Houyel, Lucile; Jalal, Zakaria; Lambert, Virginie; Ly, Mohamed; Vouhé, Pascal; Bonnet, Damien

    2016-09-01

    Surgical management of various forms of double-outlet right ventricle uses a variety of approaches depending on the underlying anatomic form. In this study, we sought to determine the risk factors of mortality and reoperation in those with double-outlet right ventricle undergoing biventricular repair, according to anatomic characteristics and initial surgical strategy. Between 1992 and 2013, 433 patients were included in the study. Double-outlet right ventricle was classified as double-outlet right ventricle with subaortic ventricular septal defect associated with subpulmonary obstruction in 33% of patients (n = 141), with subaortic ventricular septal defect without subpulmonary obstruction in 30% of patients (n = 130), with subpulmonary ventricular septal defect in 32% of patients (n = 139), and with noncommitted ventricular septal defect in 5% of patients (n = 23). Three types of repairs were performed: (1) intraventricular baffle repair, n = 149 (34%); (2) intraventricular baffle repair with right ventricular outflow tract reconstruction, n = 163 (38%); and (3) intraventricular baffle repair with arterial switch operation, n = 121 (28%). Thirty-day overall mortality was 7.4%. Early reoperation was needed in 6% of the cases. Early mortality was higher in the intraventricular baffle repair with arterial switch operation group (P = .01). Survival at 10 years was 86.2%, and freedom from reoperation at 10 years was 61.4%. At last follow-up (median, 5.7 years; 95% confidence interval, 4.5-6.6), mortality and reoperation rates were similar in the different surgical strategy groups. Late reoperation and late mortality were significantly higher in the double-outlet right ventricle with noncommitted ventricular septal defect group (P < .01). In multivariate analyses, risk factors for reoperation were concomitant surgical procedures (P = .03) and duration of cardiopulmonary bypass (P < .01). Risk factors for mortality were restrictive ventricular

  7. Anatomic changes due to interspecific grafting in cassava (Manihot esculenta).

    PubMed

    Bomfim, N; Ribeiro, D G; Nassar, N M A

    2011-05-31

    Cassava rootstocks of varieties UnB 201 and UnB 122 grafted with scions of Manihot fortalezensis were prepared for anatomic study. The roots were cut, stained with safranin and alcian blue, and examined microscopically, comparing them with sections taken from ungrafted roots. There was a significant decrease in number of pericyclic fibers, vascular vessels and tyloses in rootstocks. They exhibited significant larger vessels. These changes in anatomic structure are a consequence of genetic effects caused by transference of genetic material from scion to rootstock. The same ungrafted species was compared. This is the first report on anatomic changes due to grafting in cassava.

  8. A reusable anatomically segmented digital mannequin for public health communication.

    PubMed

    Fujieda, Kaori; Okubo, Kosaku

    2016-01-01

    The ongoing development of world wide web technologies has facilitated a change in health communication, which has now become bi-directional and encompasses people with diverse backgrounds. To enable an even greater role for medical illustrations, a data set, BodyParts3D, has been generated and its data set can be used by anyone to create and exchange customised three-dimensional (3D) anatomical images. BP3D comprises more than 3000 3D object files created by segmenting a digital mannequin in accordance with anatomical naming conventions. This paper describes the methodologies and features used to generate an anatomically correct male mannequin.

  9. Factors predicting language lateralization in patients with perisylvian vascular malformations

    PubMed Central

    Lee, Darrin J.; Pouratian, Nader; Bookheimer, Susan Y.; Martin, Neil A.

    2017-01-01

    Object The authors conducted a study to determine the factors associated with right-sided language dominance in patients with cerebrovascular malformations. Methods Twenty-two patients with either arteriovenous malformations (AVMs [15 cases]) or cavernous malformations (7 cases) underwent functional MR (fMR) imaging studies of language function; a 3.0-T head-only unit was used. Lateralization indices were calculated separately for Broca and Wernicke areas. Lesion size, Spetzler-Martin grade, and the distance between the lesion and anatomically defined language cortex were calculated for each patient. Results Right-sided language dominance occurred in 5 patients, all of whom had AVMs within 10 mm of canonical language areas. Three patients had right-sided language dominance in the Wernicke area alone whereas 2 had right-sided language dominance in both Broca and Wernicke areas. Wada testing and intraoperative electrocortical stimulation were performed as clinically indicated to corroborate fMR imaging findings. Conclusions The primary factor associated with right-sided language dominance was the AVM being within 10 mm of anatomically defined language areas. The lesion size and the Spetzler-Martin grade were not significant factors. Anomalous fMR imaging laterality was typically confined to the language area proximate to the lesion, with the distal language area remaining in the left hemisphere dominant. This study emphasizes the need to map each case individually in patients with left perisylvian AVMs. Assumptions about eloquent cortex based on anatomical landmarks (a key component of Spetzler-Martin grading) may have to be reconsidered. PMID:20302390

  10. Distribution of Prostate Sentinel Nodes: A SPECT-Derived Anatomic Atlas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ganswindt, Ute, E-mail: ute.ganswindt@med.uni-muenchen.d; Schilling, David; Mueller, Arndt-Christian

    2011-04-01

    Purpose: The randomized Radiation Therapy Oncology Group 94-13 trial revealed that coverage of the pelvic lymph nodes in high-risk prostate cancer confers an advantage (progression-free survival and biochemical failure) in patients with {>=}15% risk of lymph node involvement. To facilitate an improved definition of the adjuvant target volume, precise knowledge regarding the location of the relevant lymph nodes is necessary. Therefore, we generated a three-dimensional sentinel lymph node atlas. Methods and Materials: In 61 patients with high-risk prostate cancer, a three-dimensional visualization of sentinel lymph nodes was performed using a single photon emission computed tomography system after transrectal intraprostatic injectionmore » of 150 to 362 (median 295) mega becquerel (MBq) {sup 99m}Technetium-nanocolloid (1.5-3h after injection) followed by an anatomic functional image fusion. Results: In all, 324 sentinel nodes in 59 of 61 patients (96.7%) were detected, with 0 to 13 nodes per patient (median 5, mean 5.3). The anatomic distribution of the sentinel nodes was as follows: external iliac 34.3%, internal iliac 17.9%, common iliac 12.7%, sacral 8.6%, perirectal 6.2%, left paraaortic 5.3%, right paraaortic 5.3%, seminal vesicle lymphatic plexus 3.1%, deep inguinal 1.5%, superior rectal 1.2%, internal pudendal 1.2%, perivesical 0.9%, inferior rectal 0.9%, retroaortic 0.3%, superficial inguinal 0.3%, and periprostatic 0.3%. Conclusions: The distribution of sentinel nodes as detected by single photon emission computed tomography imaging correlates well with the distribution determined by intraoperative gamma probe detection. A lower detection rate of sentinels in close proximity to the bladder and seminal vesicles is probably caused by the radionuclide accumulation in the bladder. In regard to intensity-modulated radiotherapy techniques, the presented anatomic atlas may allow optimized target volume definitions.« less

  11. Sinonasal anatomical variations: their relationship with chronic rhinosinusitis and effect on the severity of disease-a computerized tomography assisted anatomical and clinical study.

    PubMed

    Kaygusuz, Ahmet; Haksever, Mehmet; Akduman, Davut; Aslan, Sündüs; Sayar, Zeynep

    2014-09-01

    The anatomy of the sinonasal area has a very wide rage of anatomical variations. The significance of these anatomical variations in pathogenesis of rhinosinusitis, which is the commonest disease in the region, is still unclear. The aims of the study were to compare the rate of sinonasal anatomical variations with development and severity of chronic rhinosinusitis patients. CT scan of paranasal sinuses images of 99 individuals were retrospectively reviewed. 65 cases of chronic rhinosinusitis (study group) who had undergone endoscopic sinus surgery were compared with 34 cases without chronic rhinosinusitis (control group). Also in study group Lund-Mackay score of the sinus disease were calculated and compared to the rate of related anatomical variations. There were 74 (74.7 %) males and 25 (25.2 %) females with ages ranging from 13 to 70 years (mean 32.2 years). The anatomical variations recorded were: Septal deviation 47 (72.3) in study and 25 (73.5 %) in control group, concha bullosa 27 (41.5 %) in study and 18 (52.9 %) in control group, overpneumatized ethmoid bulla 17 (26.1 %) in study and 14 (41.1 %) in control group, pneumatized uncinate 3 (4.6 %) in study and 3 (8.8 %) in control group, agger nasi 42 (64.6 %) in study and 19 (55.8 %) in control group, paradoxical middle turbinates 9 (13.8 %) in study and 4 (11.7 %) in control group, Onodi cell 6 (9.2 %) in study and 2 (5.8 %) in control group, Haller's cells (infraorbital ethmoid cell) 9 (13.8 %) in study and 7 (20.5 %) in control group. None of these results were statistically significant between study and control group (p > 0.05). Lund-Mackay score (which was assumed to show the severity of the disease) of the maxillary, ethmoid and frontal sinus were calculated and compared to rate of septal deviation, concha bullosa, agger nasi cells. No significant correlation was conducted (p > 0.05). The results of study showed no statistically significant correlation between sinonasal anatomical

  12. [Relationship between leaf anatomical structure and heat resistance of 15 Rhododendron cultivars].

    PubMed

    Shen, Hui Fei; Zhao, Bing; Xu, Jing Jing

    2016-12-01

    In this study, 17 anatomical structure indexes of 15 Rhododendron cultivars were mea-sured by scanning electron microscope (SEM). Leaf anatomical structure indexes were screened via coefficient of variation, analysis of correlation and hierarchical cluster analysis, and comprehensive evaluation on heat resistance for each cultivar was conducted by the subordinate function. The results showed that the leaves of Rhododendron cultivars were typical bifacial leaf and the epidermal anticlinal walls showed slightly sinuate. The stomata only distributed in the lower epidermis and the shape was ruleless. The anatomical structure indexes all reached a significant level difference among 15 cultivars (P<0.01), except for lower epidermis thickness (P<0.05). Thickness of lamina corneum, stomatal density, stomatal width, the thickness palisade tissue and looseness of leaf spongy tissue were the main factors related to the hardness, while other indexes, such as stomatal length, stoma aperture, stomatal opening, length and thickness of upper epidermis, length and thickness of lower epidermis, thickness of spongy tissue, the ratio of the palisade tissue to spongy tissue, tightness of leaf palisade tissue, leaf thickness and media thickness didn't show much effect on heat resistance. There were some differences among 15 cultivars in heat resistance, and the order was Rhododendron 'Song Jiang Da Tao Hong' > Rhododendron 'Zhuang Yuan Hong' > Rhododendron 'Lv Se Guang Hui' > Rhododendron 'Fen Zhen Zhu' > Rhododendron 'Wai Guo Hong' > Rhododendron 'Lan Yin' > Rhododendron 'Bi Zhi' >Rhododendron 'Da He Zhi Chun' > Rhododendron 'Guo Qi Hong' > Rhododendron 'Yu Ling Long' > Rhododendron 'Hong Shan Hu' > Rhododendron 'Ning Bo Hong' > Rhododendron 'Tao Ban Zhu Sha' > Rhododendron 'Ai Ding Bao' > Rhododendron 'Liu Qiu Hong'. According to the heat hardiness, the cultivars could be divided into 4 groups: R. 'Song Jiang Da Tao Hong', R. 'Zhuang Yuan Hong' and R. 'Lv Se Guang Hui' with high heat

  13. Comparison of large-scale human brain functional and anatomical networks in schizophrenia.

    PubMed

    Nelson, Brent G; Bassett, Danielle S; Camchong, Jazmin; Bullmore, Edward T; Lim, Kelvin O

    2017-01-01

    Schizophrenia is a disease with disruptions in thought, emotion, and behavior. The dysconnectivity hypothesis suggests these disruptions are due to aberrant brain connectivity. Many studies have identified connectivity differences but few have been able to unify gray and white matter findings into one model. Here we develop an extension of the Network-Based Statistic (NBS) called NBSm (Multimodal Network-based statistic) to compare functional and anatomical networks in schizophrenia. Structural, resting functional, and diffusion magnetic resonance imaging data were collected from 29 chronic patients with schizophrenia and 29 healthy controls. Images were preprocessed, and average time courses were extracted for 90 regions of interest (ROI). Functional connectivity matrices were estimated by pairwise correlations between wavelet coefficients of ROI time series. Following diffusion tractography, anatomical connectivity matrices were estimated by white matter streamline counts between each pair of ROIs. Global and regional strength were calculated for each modality. NBSm was used to find significant overlap between functional and anatomical components that distinguished health from schizophrenia. Global strength was decreased in patients in both functional and anatomical networks. Regional strength was decreased in all regions in functional networks and only one region in anatomical networks. NBSm identified a distinguishing functional component consisting of 46 nodes with 113 links (p < 0.001), a distinguishing anatomical component with 47 nodes and 50 links (p = 0.002), and a distinguishing intermodal component with 26 nodes (p < 0.001). NBSm is a powerful technique for understanding network-based group differences present in both anatomical and functional data. In light of the dysconnectivity hypothesis, these results provide compelling evidence for the presence of significant overlapping anatomical and functional disruption in people with schizophrenia.

  14. Evolution of the anatomical theatre in Padova.

    PubMed

    Macchi, Veronica; Porzionato, Andrea; Stecco, Carla; De Caro, Raffaele

    2014-01-01

    The anatomical theatre played a pivotal role in the evolution of medical education, allowing students to directly observe and participate in the process of dissection. Due to the increase of training programs in clinical anatomy, the Institute of Human Anatomy at the University of Padova has renovated its dissecting room. The main guidelines in planning a new anatomical theatre included: (1), the placement of the teacher and students on the same level in a horizontal anatomical theatre where it is possible to see (theatre) and to perform (dissecting room); (2), in the past, dissection activities were concentrated at the center of the theatre, while in the new anatomical theatre, such activities have been moved to the periphery through projection on surrounding screens-thus, students occupy the center of the theatre between the demonstration table, where the dissection can be seen in real time, and the wall screens, where particular aspects are magnified; (3), three groups of tables are placed with one in front with two lateral flanking tables in regards to the demonstration table, in a semicircular arrangement, and not attached to the floor, which makes the room multifunctional for surgical education, medical students and physician's continued professional development courses; (4), a learning station to introduce the students to the subject of the laboratory; (5), cooperation between anatomists and architects in order to combine the practical needs of a dissection laboratory with new technologies; (6), involvement of the students, representing the clients' needs; and (7), creation of a dissecting room of wide measurements with large windows, since a well-illuminated space could reduce the potentially negative psychological impact of the dissection laboratory on student morale. © 2014 American Association of Anatomists.

  15. Measurement of distances between anatomical structures using a translating stage with mounted endoscope

    NASA Astrophysics Data System (ADS)

    Kahrs, Lueder A.; Blachon, Gregoire S.; Balachandran, Ramya; Fitzpatrick, J. Michael; Labadie, Robert F.

    2012-02-01

    During endoscopic procedures it is often desirable to determine the distance between anatomical features. One such clinical application is percutaneous cochlear implantation (PCI), which is a minimally invasive approach to the cochlea via a single, straight drill path and can be achieved accurately using bone-implanted markers and customized microstereotactic frame. During clinical studies to validate PCI, traditional open-field cochlear implant surgery was performed and prior to completion of the surgery, a customized microstereotactic frame designed to achieve the desired PCI trajectory was attached to the bone-implanted markers. To determine whether this trajectory would have safely achieved the target, a sham drill bit is passed through the frame to ensure that the drill bit would reach the cochlea without damaging vital structures. Because of limited access within the facial recess, the distances from the bit to anatomical features could not be measured with calipers. We hypothesized that an endoscope mounted on a sliding stage that translates only along the trajectory, would provide sufficient triangulation to accurately measure these distances. In this paper, the design, fabrication, and testing of such a system is described. The endoscope is mounted so that its optical axis is approximately aligned with the trajectory. Several images are acquired as the stage is moved, and threedimensional reconstruction of selected points allows determination of distances. This concept also has applicability in a large variety of rigid endoscopic interventions including bronchoscopy, laparoscopy, and sinus endoscopy.

  16. Live Donor Renal Anatomic Asymmetry and Posttransplant Renal Function.

    PubMed

    Tanriover, Bekir; Fernandez, Sonalis; Campenot, Eric S; Newhouse, Jeffrey H; Oyfe, Irina; Mohan, Prince; Sandikci, Burhaneddin; Radhakrishnan, Jai; Wexler, Jennifer J; Carroll, Maureen A; Sharif, Sairah; Cohen, David J; Ratner, Lloyd E; Hardy, Mark A

    2015-08-01

    Relationship between live donor renal anatomic asymmetry and posttransplant recipient function has not been studied extensively. We analyzed 96 live kidney donors, who had anatomical asymmetry (>10% renal length and/or volume difference calculated from computerized tomography angiograms) and their matching recipients. Split function differences (SFD) were quantified with technetium-dimercaptosuccinic acid renography. Implantation biopsies at time 0 were semiquantitatively scored. A comprehensive model using donor renal volume adjusted to recipient weight (Vol/Wgt), SFD, and biopsy score was used to predict recipient estimated glomerular filtration rate (eGFR) at 1 year. Primary analysis consisted of a logistic regression model of outcome (odds of developing eGFR>60 mL/min/1.73 m(2) at 1 year), a linear regression model of outcome (predicting recipient eGFR at one-year, using the chronic kidney disease-epidemiology collaboration formula), and a Monte Carlo simulation based on the linear regression model (N=10,000 iterations). In the study cohort, the mean Vol/Wgt and eGFR at 1 year were 2.04 mL/kg and 60.4 mL/min/1.73 m(2), respectively. Volume and split ratios between 2 donor kidneys were strongly correlated (r = 0.79, P < 0.001). The biopsy scores among SFD categories (<5%, 5%-10%, >10%) were not different (P = 0.190). On multivariate models, only Vol/Wgt was significantly associated with higher odds of having eGFR > 60 mL/min/1.73 m (odds ratio, 8.94, 95% CI 2.47-32.25, P = 0.001) and had a strong discriminatory power in predicting the risk of eGFR less than 60 mL/min/1.73 m(2) at 1 year [receiver operating curve (ROC curve), 0.78, 95% CI, 0.68-0.89]. In the presence of donor renal anatomic asymmetry, Vol/Wgt appears to be a major determinant of recipient renal function at 1 year after transplantation. Renography can be replaced with CT volume calculation in estimating split renal function.

  17. Detectability of radiological images: the influence of anatomical noise

    NASA Astrophysics Data System (ADS)

    Bochud, Francois O.; Verdun, Francis R.; Hessler, Christian; Valley, Jean-Francois

    1995-04-01

    Radiological image quality can be objectively quantified by the statistical decision theory. This theory is commonly applied with the noise of the imaging system alone (quantum, screen and film noises) whereas the actual noise present on the image is the 'anatomical noise' (sum of the system noise and the anatomical texture). This anatomical texture should play a role in the detection task. This paper compares these two kinds of noises by performing 2AFC experiments and computing the area under the ROC-curve. It is shown that the 'anatomical noise' cannot be considered as a noise in the sense of Wiener spectrum approach and that the detectability performance is the same as the one obtained with the system noise alone in the case of a small object to be detected. Furthermore, the statistical decision theory and the non- prewhitening observer does not match the experimental results. This is especially the case in the low contrast values for which the theory predicts an increase of the detectability as soon as the contrast is different from zero whereas the experimental result demonstrates an offset of the contrast value below which the detectability is purely random. The theory therefore needs to be improved in order to take this result into account.

  18. Anatomical Mercury: Changing Understandings of Quicksilver, Blood, and the Lymphatic System, 1650-1800.

    PubMed

    Hendriksen, Marieke M A

    2015-10-01

    The use of mercury as an injection mass in anatomical experiments and preparations was common throughout Europe in the long eighteenth century, and refined mercury-injected preparations as well as plates of anatomical mercury remain today. The use and meaning of mercury in related disciplines such as medicine and chemistry in the same period have been studied, but our knowledge of anatomical mercury is sparse and tends to focus on technicalities. This article argues that mercury had a distinct meaning in anatomy, which was initially influenced by alchemical and classical understandings of mercury. Moreover, it demonstrates that the choice of mercury as an anatomical injection mass was deliberate and informed by an intricate cultural understanding of its materiality, and that its use in anatomical preparations and its perception as an anatomical material evolved with the understanding of the circulatory and lymphatic systems. By using the material culture of anatomical mercury as a starting point, I seek to provide a new, object-driven interpretation of complex and strongly interrelated historiographical categories such as mechanism, vitalism, chemistry, anatomy, and physiology, which are difficult to understand through a historiography that focuses exclusively on ideas. © The Author 2014. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  19. Increased Anatomical Specificity of Neuromodulation via Modulated Focused Ultrasound

    PubMed Central

    Mehić, Edin; Xu, Julia M.; Caler, Connor J.; Coulson, Nathaniel K.; Moritz, Chet T.; Mourad, Pierre D.

    2014-01-01

    Transcranial ultrasound can alter brain function transiently and nondestructively, offering a new tool to study brain function now and inform future therapies. Previous research on neuromodulation implemented pulsed low-frequency (250–700 kHz) ultrasound with spatial peak temporal average intensities (ISPTA) of 0.1–10 W/cm2. That work used transducers that either insonified relatively large volumes of mouse brain (several mL) with relatively low-frequency ultrasound and produced bilateral motor responses, or relatively small volumes of brain (on the order of 0.06 mL) with relatively high-frequency ultrasound that produced unilateral motor responses. This study seeks to increase anatomical specificity to neuromodulation with modulated focused ultrasound (mFU). Here, ‘modulated’ means modifying a focused 2-MHz carrier signal dynamically with a 500-kHz signal as in vibro-acoustography, thereby creating a low-frequency but small volume (approximately 0.015 mL) source of neuromodulation. Application of transcranial mFU to lightly anesthetized mice produced various motor movements with high spatial selectivity (on the order of 1 mm) that scaled with the temporal average ultrasound intensity. Alone, mFU and focused ultrasound (FUS) each induced motor activity, including unilateral motions, though anatomical location and type of motion varied. Future work should include larger animal models to determine the relative efficacy of mFU versus FUS. Other studies should determine the biophysical processes through which they act. Also of interest is exploration of the potential research and clinical applications for targeted, transcranial neuromodulation created by modulated focused ultrasound, especially mFU’s ability to produce compact sources of ultrasound at the very low frequencies (10–100s of Hertz) that are commensurate with the natural frequencies of the brain. PMID:24504255

  20. Anatomic motor point localization for partial quadriceps block in spasticity.

    PubMed

    Albert, T; Yelnik, A; Colle, F; Bonan, I; Lassau, J P

    2000-03-01

    To identify the location of the vastus intermedius nerve and its motor point (point M) and to precisely identify its coordinates in relation to anatomic surface landmarks. Descriptive study. Anatomy institute of a university school of medicine. Twenty-nine adult cadaver limbs immobilized in anatomic position. Anatomic dissection to identify point M. Anatomic surface landmarks were point F, the issuing point of femoral nerve under the inguinal ligament; point R, the middle of superior edge of the patella; segment FR, which corresponds to thigh length; point M', point M orthogonal projection on segment FR. Absolute vertical coordinate, distance FM, relative vertical coordinate compared to the thigh length, FM'/FR ratio; absolute horizontal coordinate, distance MM'. The absolute vertical coordinate was 11.7+/-2 cm. The relative vertical coordinate was at .29+/-.04 of thigh length. The horizontal coordinate was at 2+/-.5 cm lateral to the FR line. Point M can be defined with relative precision by two coordinates. Application and clinical interest of nerve blocking using these coordinates in quadriceps spasticity should be studied.

  1. [Anatomical Vitamin C-Research during National Socialism and the Post-war Period: Max Clara's Human Experiments at the Munich Anatomical Institute].

    PubMed

    Schûtz, Mathias; Schochow, Maximilian; Waschke, Jens; Marckmann, Georg; Steger, Florian

    2014-01-01

    In autumn of 1942, Max Clara (1899-1966) became chairman of the anatomical institute Munich. There, he intensified his research concerning the proof of vitamin C with the bodies of executed prisoners which were delivered by the Munich-Stadelheim prison. This research on human organs was pursued by applying ascorbic acid (Cebion) to prisoners before their execution. The paper investigates this intensified and radicalized anatomical research through human experiments, which Max Clara conducted in Munich and published from Istanbul during the postwar years, as well as its scientific references from the Nazi period.

  2. Linking Brain Arteriovenous Malformations With Anorectal Hemorrhoids: A Clinical and Anatomical Review

    PubMed Central

    Cuoco, Joshua A.; Hoehmann, Christopher L.; Hitscherich, Kyle; Zakhary, Sherry M.; Leheste, Joerg R.

    2017-01-01

    ABSTRACT Patients who harbor brain arteriovenous malformations are at risk for intracranial hemorrhage. These malformations are often seen in inherited vascular diseases such as hereditary hemorrhagic telangiectasia. However, malformations within the brain also sporadically occur without a hereditary‐coding component. Here, we review recent insights into the pathophysiology of arteriovenous malformations, in particular, certain signaling pathways that might underlie endothelial cell pathology. To better interpret the origins, determinants and consequences of brain arteriovenous malformations, we present a clinical case to illustrate the phenotypic landscape of the disease. We also propose that brain arteriovenous malformations might share certain signaling dimensions with those of anorectal hemorrhoids. This working hypothesis provides casual anchors from which to understand vascular diseases characterized by arteriovenous lesions with a hemorrhagic‐ or bleeding‐risk component. Anat Rec, 2017. © The Authors. The Anatomical Record published by Wiley Periodicals, Inc. on behalf of American Association of Anatomists. Anat Rec, 300:1973–1980, 2017. © 2017 The Authors. The Anatomical Record published by Wiley Periodicals, Inc. on behalf of American Association of Anatomists. PMID:28696502

  3. Mid-twentieth-century anatomical transparencies and the depiction of three-dimensional form.

    PubMed

    Wall, Shelley

    2010-11-01

    Before the advent of digital visualization, the "anatomical transparency"--layered images of organ systems, printed on a transparent medium--flourished in the mid-twentieth century as an interactive means to represent complex anatomical relationships to medical professionals and lay audiences. This article introduces the transparency work of medical illustrators Gladys McHugh and Ernest W. Beck, situating it in the historical context of strategies to represent three-dimensional anatomical relationships using print media.

  4. Using 3D modeling techniques to enhance teaching of difficult anatomical concepts

    PubMed Central

    Pujol, Sonia; Baldwin, Michael; Nassiri, Joshua; Kikinis, Ron; Shaffer, Kitt

    2016-01-01

    Rationale and Objectives Anatomy is an essential component of medical education as it is critical for the accurate diagnosis in organs and human systems. The mental representation of the shape and organization of different anatomical structures is a crucial step in the learning process. The purpose of this pilot study is to demonstrate the feasibility and benefits of developing innovative teaching modules for anatomy education of first-year medical students based on 3D reconstructions from actual patient data. Materials and Methods A total of 196 models of anatomical structures from 16 anonymized CT datasets were generated using the 3D Slicer open-source software platform. The models focused on three anatomical areas: the mediastinum, the upper abdomen and the pelvis. Online optional quizzes were offered to first-year medical students to assess their comprehension in the areas of interest. Specific tasks were designed for students to complete using the 3D models. Results Scores of the quizzes confirmed a lack of understanding of 3D spatial relationships of anatomical structures despite standard instruction including dissection. Written task material and qualitative review by students suggested that interaction with 3D models led to a better understanding of the shape and spatial relationships among structures, and helped illustrate anatomical variations from one body to another. Conclusion The study demonstrates the feasibility of one possible approach to the generation of 3D models of the anatomy from actual patient data. The educational materials developed have the potential to supplement the teaching of complex anatomical regions and help demonstrate the anatomic variation among patients. PMID:26897601

  5. Is anatomic acetabular orientation related to pelvic morphology? CT analysis of 150 healthy pelvises.

    PubMed

    Sautet, P; Giorgi, H; Chabrand, P; Tropiano, P; Argenson, J-N; Parratte, S; Blondel, B

    2018-05-01

    Links between sagittal spinal alignment and acetabular orientation attract considerable research attention with the goal of optimising prosthetic cup position. However, whether pelvic incidence (PI) is related to anatomic acetabular orientation remains unknown. We therefore conducted a radiological study with the following objectives: to look for correlations between PI and anatomic acetabular parameters; to describe the sacro-pubic angle (SPA), defined by fixed bony pelvic landmarks, and its relations with acetabular anteversion; and to determine whether anatomical parameters (PI and SPA) correlate with demographic characteristics. PI correlates with anatomical acetabular parameters. We conducted a computed tomography (CT) study of the pelvises of 150 patients free of degenerative disease. Three parameters were measured: anatomic acetabular orientation in the Lewinnek reference plane, PI, and the SPA subtended by the line connecting the midpoint of the sacral endplate to the pubic symphysis and the anterior pelvic plane. Statistical tests were performed to look for correlations among these parameters. Intra-observer and inter-observer reproducibility was considered highly satisfactory (inter-class correlation coefficient, >86% and >82%, respectively). Mean PI was 58.6°±10.2° (range, 32.8°-97.6°), with no significant differences between genders or across age groups. Mean SPA was 34.7°±5.5° (range, 18.3°-49.8°). Mean anatomic acetabular anteversion (AAA) was greater in females (23.4°; range, 11.5°-34.5°) than in males (20°; range, 7.5°-34.5°) (P<0.001). PI did not correlate with any of the acetabular parameters (PI/AAA, r=0.8 and P=0.33; PI/acetabular inclination on the horizontal, r=-0.96 and P=0.24). SPA correlated significantly with both PI (r=0.33 and P<0.001) and AAA (r=0.33 and P<0.001). This CT study of normal pelvises showed that AAA was significantly greater in females and that SPA correlated significantly with both PI and acetabular

  6. Anatomical models and wax Venuses: art masterpieces or scientific craft works?

    PubMed Central

    Ballestriero, R

    2010-01-01

    The art of wax modelling has an ancient origin but rose to prominence in 14th century Italy with the cult of votive artefacts. With the advent of Neoclassicism this art, now deemed repulsive, continued to survive in a scientific environment, where it flourished in the study of normal and pathological anatomy, obstetrics, zoology and botany. The achievement of having originated the creation of anatomical models in coloured wax must be ascribed to a joint effort undertaken by the Sicilian wax modeller Gaetano Giulio Zumbo and the French surgeon Guillaume Desnoues in the late 17th century. Interest in anatomical wax models spread throughout Europe during the 18th century, first in Bologna with Ercole Lelli, Giovanni Manzolini and Anna Morandi, and then in Florence with Felice Fontana and Clemente Susini. In England, the art of anatomical ceroplastics was brought to London from Florence by the sculptor Joseph Towne. Throughout the centuries many anatomical artists preferred this material due to the remarkable mimetic likeness obtained, far surpassing any other material. Independent of the material used, whether wood, wax or clay, anatomical models were always considered merely craft works confined to hospitals or faculties of medicine and have survived to this day only because of their scientific interest. Italian and English waxes are stylistically different but the remarkable results obtained by Susini and Towne, and the fact that some contemporary artists are again representing anatomical wax bodies in their works, makes the border that formerly separated art and craft indistinguishable. PMID:20002228

  7. Anatomical models and wax Venuses: art masterpieces or scientific craft works?

    PubMed

    Ballestriero, R

    2010-02-01

    The art of wax modelling has an ancient origin but rose to prominence in 14th century Italy with the cult of votive artefacts. With the advent of Neoclassicism this art, now deemed repulsive, continued to survive in a scientific environment, where it flourished in the study of normal and pathological anatomy, obstetrics, zoology and botany. The achievement of having originated the creation of anatomical models in coloured wax must be ascribed to a joint effort undertaken by the Sicilian wax modeller Gaetano Giulio Zumbo and the French surgeon Guillaume Desnoues in the late 17th century. Interest in anatomical wax models spread throughout Europe during the 18th century, first in Bologna with Ercole Lelli, Giovanni Manzolini and Anna Morandi, and then in Florence with Felice Fontana and Clemente Susini. In England, the art of anatomical ceroplastics was brought to London from Florence by the sculptor Joseph Towne. Throughout the centuries many anatomical artists preferred this material due to the remarkable mimetic likeness obtained, far surpassing any other material. Independent of the material used, whether wood, wax or clay, anatomical models were always considered merely craft works confined to hospitals or faculties of medicine and have survived to this day only because of their scientific interest. Italian and English waxes are stylistically different but the remarkable results obtained by Susini and Towne, and the fact that some contemporary artists are again representing anatomical wax bodies in their works, makes the border that formerly separated art and craft indistinguishable.

  8. Anatomical and Physiological Responses of Citrus Trees to Varying Boron Availability Are Dependent on Rootstock.

    PubMed

    Mesquita, Geisa L; Zambrosi, Fernando C B; Tanaka, Francisco A O; Boaretto, Rodrigo M; Quaggio, José A; Ribeiro, Rafael V; Mattos, Dirceu

    2016-01-01

    In Citrus, water, nutrient transport and thereby fruit production, are influenced among other factors, by the interaction between rootstock and boron (B) nutrition. This study aimed to investigate how B affects the anatomical structure of roots and leaves as well as leaf gas exchange in sweet orange trees grafted on two contrasting rootstocks in response to B supply. Plants grafted on Swingle citrumelo or Sunki mandarin were grown in a nutrient solution of varying B concentration (deficient, adequate, and excessive). Those grafted on Swingle were more tolerant to both B deficiency and toxicity than those on Sunki, as revealed by higher shoot and root growth. In addition, plants grafted on Sunki exhibited more severe anatomical and physiological damages under B deficiency, showing thickening of xylem cell walls and impairments in whole-plant leaf-specific hydraulic conductance and leaf CO2 assimilation. Our data revealed that trees grafted on Swingle sustain better growth under low B availablitlity in the root medium and still respond positively to increased B levels by combining higher B absorption and root growth as well as better organization of xylem vessels. Taken together, those traits improved water and B transport to the plant canopy. Under B toxicity, Swingle rootstock would also favor plant growth by reducing anatomical and ultrastructural damage to leaf tissue and improving water transport compared with plants grafted on Sunki. From a practical point of view, our results highlight that B management in citrus orchards shall take into account rootstock varieties, of which the Swingle rootstock was characterized by its performance on regulating anatomical and ultrastructural damages, improving water transport and limiting negative impacts of B stress conditions on plant growth.

  9. Anatomical exploration of a dicephalous goat kid using sheet plastination (E12).

    PubMed

    Elnady, Fawzy; Sora, Mircea-Constantin

    2009-06-01

    A dicephalous, 1-day-old, female goat kid was presented for anatomical study. Epoxy plastination slices (E12) were used successfully to explore this condition. They provided excellent anatomic and bone detail, demonstrating organ position, shared structures, and vascular anatomy. Sheet plastination (E12) was used as an optimal method to clarify how the two heads were united, especially the neuroanatomy. The plastinated transparent slices allowed detailed study of the anatomical structures, in a non-collapsed and non-dislocated state. Thus, we anatomically explored this rare condition without traditional dissection. The advantages of plastination extended to the preservation at room temperature of this case for further topographical investigation. To the authors' best knowledge, this is the first published report of plastination of a dicephalous goat.

  10. Incidence, Causative Mechanisms, and Anatomic Localization of Stroke in Pituitary Adenoma Patients Treated With Postoperative Radiation Therapy Versus Surgery Alone

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sattler, Margriet G.A., E-mail: g.a.sattler@umcg.nl; Department of Radiation Oncology, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, ON; Vroomen, Patrick C.

    Purpose: To assess and compare the incidence of stroke and stroke subtype in pituitary adenoma patients treated with postoperative radiation therapy (RT) and surgery alone. Methods and Materials: A cohort of 462 pituitary adenoma patients treated between 1959 and 2008 at the University Medical Center Groningen in The Netherlands was studied. Radiation therapy was administered in 236 patients. The TOAST (Trial of ORG 10172 in Acute Stroke Treatment) and the Oxfordshire Community Stroke Project classification methods were used to determine causative mechanism and anatomic localization of stroke. Stroke incidences in patients treated with RT were compared with that observed aftermore » surgery alone. Risk factors for stroke incidence were studied by log–rank test, without and with stratification for other significant risk factors. In addition, the stroke incidence was compared with the incidence rate in the general Dutch population. Results: Thirteen RT patients were diagnosed with stroke, compared with 12 surgery-alone patients. The relative risk (RR) for stroke in patients treated with postoperative RT was not significantly different compared with surgery-alone patients (univariate RR 0.62, 95% confidence interval [CI] 0.28-1.35, P=.23). Stroke risk factors were coronary or peripheral artery disease (univariate and multivariate RR 10.4, 95% CI 4.7-22.8, P<.001) and hypertension (univariate RR 3.9, 95% CI 1.6-9.8, P=.002). There was no difference in TOAST and Oxfordshire classification of stroke. In this pituitary adenoma cohort 25 strokes were observed, compared with 16.91 expected (standard incidence ratio 1.48, 95% CI 1.00-1.96, P=.049). Conclusions: In pituitary adenoma patients, an increased incidence of stroke was observed compared with the general population. However, postoperative RT was not associated with an increased incidence of stroke or differences in causative mechanism or anatomic localization of stroke compared with surgery alone. The primary

  11. Genetic Factors in Determining Bone Mass

    PubMed Central

    Smith, David M.; Nance, Walter E.; Kang, Ke Won; Christian, Joe C.; Johnston, C. Conrad

    1973-01-01

    This investigation was undertaken to evaluate possible genetic determinants of bone mass with the premise that inheritance of bone mass could be of etiologic importance in osteoporosis. Bone mass and width measurements were made with the photon absorption technique on the right radius of 71 juvenile and 80 adult twin paris. The variance of intrapair differences of bone mass in monozygotic (MZ) juvenile twins was 0.0013 g2/cm2 compared to 0.0052 g2/cm2 in the dizygotic (DZ) twins. For the adult twins the variance of intrapair differences in bone mass was 0.0069 for MZ and 0.0137 for DZ twins. Similar results were obtained for bone width. The significantly larger variation in intrapair differences in DZ twins indicates that these traits have significant genetic determinants. These intrapair differences were found to increase with age, suggesting that genetic-environmental interaction also contributes to the observed variation in bone mass. These data provide evidence that bone mass does have significant genetic factors, which alone or in conjunction with environmental factors may predispose persons to the development of osteoporosis. PMID:4795916

  12. Computed tomography-based anatomic characterization of proximal aortic dissection with consideration for endovascular candidacy.

    PubMed

    Moon, Michael C; Greenberg, Roy K; Morales, Jose P; Martin, Zenia; Lu, Qingsheng; Dowdall, Joseph F; Hernandez, Adrian V

    2011-04-01

    Proximal aortic dissections are life-threatening conditions that require immediate surgical intervention to avert an untreated mortality rate that approaches 50% at 48 hours. Advances in computed tomography (CT) imaging techniques have permitted increased characterization of aortic dissection that are necessary to assess the design and applicability of new treatment paradigms. All patients presenting during a 2-year period with acute proximal aortic dissections who underwent CT scanning were reviewed in an effort to establish a detailed assessment of their aortic anatomy. Imaging studies were assessed in an effort to document the location of the primary proximal fenestration, the proximal and distal extent of the dissection, and numerous morphologic measurements pertaining to the aortic valve, root, and ascending aorta to determine the potential for an endovascular exclusion of the ascending aorta. During the study period, 162 patients presented with proximal aortic dissections. Digital high-resolution preoperative CT imaging was performed on 76 patients, and 59 scans (77%) were of adequate quality to allow assessment of anatomic suitability for treatment with an endograft. In all cases, the dissection plane was detectable, yet the primary intimal fenestration was identified in only 41% of the studies. Scans showed 24 patients (32%) appeared to be anatomically amenable to such a repair (absence of valvular involvement, appropriate length and diameter of proximal sealing regions, lack of need to occlude coronary vasculature). Of the 42 scans that were determined not to be favorable for endovascular repair, the most common exclusion finding was the absence of a proximal landing zone (n = 15; 36%). Appropriately protocoled CT imaging provides detailed anatomic information about the aortic root and ascending aorta, allowing the assessment of which dissections have proximal fenestrations that may be amenable to an endovascular repair. Copyright © 2011 Society for

  13. A new method to predict anatomical outcome after idiopathic macular hole surgery.

    PubMed

    Liu, Peipei; Sun, Yaoyao; Dong, Chongya; Song, Dan; Jiang, Yanrong; Liang, Jianhong; Yin, Hong; Li, Xiaoxin; Zhao, Mingwei

    2016-04-01

    To investigate whether a new macular hole closure index (MHCI) could predict anatomic outcome of macular hole surgery. A vitrectomy with internal limiting membrane peeling, air-fluid exchange, and gas tamponade were performed on all patients. The postoperative anatomic status of the macular hole was defined by spectral-domain OCT. MHCI was calculated as (M+N)/BASE based on the preoperative OCT status. M and N were the curve lengths of the detached photoreceptor arms, and BASE was the length of the retinal pigment epithelial layer (RPE layer) detaching from the photoreceptors. Postoperative anatomical outcomes were divided into three grades: A (bridge-like closure), B (good closure), and C (poor closure or no closure). Correlation analysis was performed between anatomical outcomes and MHCI. Receiver operating characteristic (ROC) curves were derived for MHCI, indicating good model discrimination. ROC curves were also assessed by the area under the curve, and cut-offs were calculated. Other predictive parameters reported previously, which included the MH minimum, the MH height, the macular hole index (MHI), the diameter hole index (DHI), and the tractional hole index (THI) had been compared as well. MHCI correlated significantly with postoperative anatomical outcomes (r = 0.543, p = 0.000), but other predictive parameters did not. The areas under the curves indicated that MHCI could be used as an effective predictor of anatomical outcome. Cut-off values of 0.7 and 1.0 were obtained for MHCI from ROC curve analysis. MHCI demonstrated a better predictive effect than other parameters, both in the correlation analysis and ROC analysis. MHCI could be an easily measured and accurate predictive index for postoperative anatomical outcomes.

  14. Computer tomographic imaging and anatomic correlation of the human brain: A comparative atlas of thin CT-scan sections and correlated neuro-anatomic preparations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Plets, C.; Baert, A.L.; Nijs, G.L.

    1986-01-01

    It is of the greatest importance to the radiologist, the neurologist and the neurosurgeon to be able to localize topographically a pathological brain process on the CT scan as precisely as possible. For that purpose, the identification of as many anatomical structures as possible on the CT scan image are necessary and indispensable. In this atlas a great number of detailed anatomical data on frontal horizontal CT scan sections, each being only 2 mm thick, are indicated, e.g. the cortical gyri, the basal ganglia, details of the white matter, extracranial muscles and blood vessels, parts of the base and themore » vault of the skull, etc. The very precise topographical description of the numerous CT scan images was realized by the author by confrontation of these images with the corresponding anatomical sections of the same brain specimen, performed by an original technique.« less

  15. Informatics for practicing anatomical pathologists: marking a new era in pathology practice.

    PubMed

    Gabril, Manal Y; Yousef, George M

    2010-03-01

    Informatics can be defined as using highly advanced technologies to improve patient diagnosis or management. Pathology informatics had evolved as a response to the overwhelming amount of information that was available, in an attempt to better use and maintain them. The most commonly used tools of informatics can be classified into digital imaging, telepathology, as well as Internet and electronic data mining. Digital imaging is the storage of anatomical pathology information, either gross pictures or microscopic slides, in an electronic format. These images can be used for education, archival, diagnosis, and consultation. Virtual microscopy is the more advanced form of digital imaging with enhanced efficiency and accessibility. Telepathology is now increasingly becoming a useful tool in anatomical pathology practice. Different types of telepathology communications are available for both diagnostic and consultation services. The spectrum of applications of informatics in the field of anatomical pathology is broad and encompasses medical education, clinical services, and pathology research. Informatics is now settling on solid ground as an important tool for pathology teaching, with digital teaching becoming the standard tool in many institutions. After a slow start, we now witness the transition of informatics from the research bench to bedside. As we are moving into a new era of extensive pathology informatics utilization, several challenges have to be addressed, including the cost of the new technology, legal issues, and resistance of pathologists. It is clear from the current evidence that pathology informatics will continue to grow and have a major role in the future of our specialty. However, it is also clear that it is not going to fully replace the human factor or the regular microscope.

  16. Anatomical causes of female infertility and their management.

    PubMed

    Abrao, Mauricio S; Muzii, Ludovico; Marana, Riccardo

    2013-12-01

    The main female anatomical causes of infertility include post-infectious tubal damage, endometriosis, and congenital/acquired uterine anomalies. Congenital (septate uterus) and acquired (myomas and synechiae) diseases of the uterus may lead to infertility, pregnancy loss, and other obstetric complications. Pelvic inflammatory disease represents the most common cause of tubal damage. Surgery still remains an important option for tubal factor infertility, with results in terms of reproductive outcome that compare favorably with those of in vitro fertilization. Endometriosis is a common gynecologic condition affecting women of reproductive age, which can cause pain and infertility. The cause of infertility associated with endometriosis remains elusive, suggesting a multifactorial mechanism involving immunologic, genetic, and environmental factors. Despite the high prevalence of endometriosis, the exact mechanisms of its pathogenesis are unknown. Specific combinations of medical, surgical, and psychological treatments can ameliorate the quality of life of women with endometriosis. In the majority of cases, surgical treatment of endometriosis has promoted significant increases in fertilization rates. There are obvious associations between endometriosis and the immune system, and future strategies to treat endometriosis might be based on immunologic concepts. © 2013.

  17. Squamous cell carcinoma – similarities and differences among anatomical sites

    PubMed Central

    Yan, Wusheng; Wistuba, Ignacio I; Emmert-Buck, Michael R; Erickson, Heidi S

    2011-01-01

    Squamous cell carcinoma (SCC) is an epithelial malignancy involving many anatomical sites and is the most common cancer capable of metastatic spread. Development of early diagnosis methods and novel therapeutics are important for prevention and mortality reduction. In this effort, numerous molecular alterations have been described in SCCs. SCCs share many phenotypic and molecular characteristics, but they have not been extensively compared. This article reviews SCC as a disease, including: epidemiology, pathology, risk factors, molecular characteristics, prognostic markers, targeted therapy, and a new approach to studying SCCs. Through this comparison, several themes are apparent. For example, HPV infection is a common risk factor among the four major SCCs (NMSC, HNSC, ESCC, and NSCLC) and molecular abnormalities in cell-cycle regulation and signal transduction predominate. These data reveal that the molecular insights, new markers, and drug targets discovered in individual SCCs may shed light on this type of cancer as a whole. PMID:21938273

  18. Determination of transmission factors in beta radiation beams.

    PubMed

    Polo, Ivón Oramas; Caldas, Linda V E

    2018-06-01

    In beta emitters, in order to evaluate the absorbed dose rate at different tissue depths, it is necessary to determine the transmission factors. In this work, the transmission factors determined in beta secondary standard radiation beams are presented. For this purpose, an extrapolation chamber was used. The results obtained were considered acceptable, and they are within the uncertainties in comparison with the values provided by the source calibration certificate. The maximum differences between the results obtained in this work and those from the calibration certificate were 3.3%, 3.8% and 5.9% for 90 Sr/ 90 Y, 85 Kr and 147 Pm sources respectively. Copyright © 2018 Elsevier Ltd. All rights reserved.

  19. Prostatome: A combined anatomical and disease based MRI atlas of the prostate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rusu, Mirabela; Madabhushi, Anant, E-mail: anant.madabhushi@case.edu; Bloch, B. Nicolas

    Purpose: In this work, the authors introduce a novel framework, the anatomically constrained registration (AnCoR) scheme and apply it to create a fused anatomic-disease atlas of the prostate which the authors refer to as the prostatome. The prostatome combines a MRI based anatomic and a histology based disease atlas. Statistical imaging atlases allow for the integration of information across multiple scales and imaging modalities into a single canonical representation, in turn enabling a fused anatomical-disease representation which may facilitate the characterization of disease appearance relative to anatomic structures. While statistical atlases have been extensively developed and studied for the brain,more » approaches that have attempted to combine pathology and imaging data for study of prostate pathology are not extant. This works seeks to address this gap. Methods: The AnCoR framework optimizes a scoring function composed of two surface (prostate and central gland) misalignment measures and one intensity-based similarity term. This ensures the correct mapping of anatomic regions into the atlas, even when regional MRI intensities are inconsistent or highly variable between subjects. The framework allows for creation of an anatomic imaging and a disease atlas, while enabling their fusion into the anatomic imaging-disease atlas. The atlas presented here was constructed using 83 subjects with biopsy confirmed cancer who had pre-operative MRI (collected at two institutions) followed by radical prostatectomy. The imaging atlas results from mapping thein vivo MRI into the canonical space, while the anatomic regions serve as domain constraints. Elastic co-registration MRI and corresponding ex vivo histology provides “ground truth” mapping of cancer extent on in vivo imaging for 23 subjects. Results: AnCoR was evaluated relative to alternative construction strategies that use either MRI intensities or the prostate surface alone for registration. The An

  20. Anatomic variations of the branches of the aortic arch in a Peruvian population.

    PubMed

    Huapaya, Julio Arturo; Chávez-Trujillo, Kristhy; Trelles, Miguel; Dueñas Carbajal, Roy; Ferrandiz Espadin, Renato

    2015-07-31

    Previous publications from two countries in South America found one anatomical variation not previously reported in the rest of the world, which in turn give some clues with regard to a racial difference. The objective of the present study is to describe variations in the anatomical distribution of the branches of the aortic arch in a Peruvian population. To describe variations in the anatomical distribution of the branches of the aortic arch in a Peruvian population. A descriptive study of patients who underwent a tomography angiography of the aorta was performed. We analyzed the reports that showed the description of the variations of the branches of the aortic arch based on the eight types currently described in the literature. From 361 analyzed reports, 282 patients (78.12%) had a normal aortic arch configuration (type I; aortic arch gives rise to the brachiocephalic trunk, left common carotid and left subclavian arteries); followed by type II (left common carotid artery as a branch of the aorta) with 41 patients (11.36%); and type IX (common ostium for the brachiocephalic trunk and the left common carotid artery) with 25 patients (6.93%). The latter and two other types are new variations. Aortic Arch Type I, Type II and Type IX were the most frequent variations in this Peruvian study. Additionally, we also found two more new types that have not been previously described in the literature. Further investigation regarding these variations is needed in order to assess a racial factor in South America and possible relationships with clinical or surgical events.

  1. Anatomical Correlates of Non-Verbal Perception in Dementia Patients.

    PubMed

    Lin, Pin-Hsuan; Chen, Hsiu-Hui; Chen, Nai-Ching; Chang, Wen-Neng; Huang, Chi-Wei; Chang, Ya-Ting; Hsu, Shih-Wei; Hsu, Che-Wei; Chang, Chiung-Chih

    2016-01-01

    Patients with dementia who have dissociations in verbal and non-verbal sound processing may offer insights into the anatomic basis for highly related auditory modes. To determine the neuronal networks on non-verbal perception, 16 patients with Alzheimer's dementia (AD), 15 with behavior variant fronto-temporal dementia (bv-FTD), 14 with semantic dementia (SD) were evaluated and compared with 15 age-matched controls. Neuropsychological and auditory perceptive tasks were included to test the ability to compare pitch changes, scale-violated melody and for naming and associating with environmental sound. The brain 3D T1 images were acquired and voxel-based morphometry (VBM) was used to compare and correlated the volumetric measures with task scores. The SD group scored the lowest among 3 groups in pitch or scale-violated melody tasks. In the environmental sound test, the SD group also showed impairment in naming and also in associating sound with pictures. The AD and bv-FTD groups, compared with the controls, showed no differences in all tests. VBM with task score correlation showed that atrophy in the right supra-marginal and superior temporal gyri was strongly related to deficits in detecting violated scales, while atrophy in the bilateral anterior temporal poles and left medial temporal structures was related to deficits in environmental sound recognition. Auditory perception of pitch, scale-violated melody or environmental sound reflects anatomical degeneration in dementia patients and the processing of non-verbal sounds are mediated by distinct neural circuits.

  2. An anatomically based protocol for the description of foot segment kinematics during gait.

    PubMed

    Leardini, A; Benedetti, M G; Catani, F; Simoncini, L; Giannini, S

    1999-10-01

    To design a technique for the in vivo description of ankle and other foot joint rotations to be applied in routine functional evaluation using non-invasive stereophotogrammetry. Position and orientation of tibia/fibula, calcaneus, mid-foot, 1st metatarsal and hallux segments were tracked during the stance phase of walking in nine asymptomatic subjects. Rigid clusters of reflective markers were used for foot segment pose estimation. Anatomical landmark calibration was applied for the reconstruction of anatomical landmarks. Previous studies have analysed only a limited number of joints or have proposed invasive techniques. Anatomical landmark trajectories were reconstructed in the laboratory frame using data from the anatomical calibration procedure. Anatomical co-ordinate frames were defined using the obtained landmark trajectories. Joint co-ordinate systems were used to calculate corresponding joint rotations in all three anatomical planes. The patterns of the joint rotations were highly repeatable within subjects. Consistent patterns between subjects were also exhibited at most of the joints. The method proposed enables a detailed description of ankle and other foot joint rotations on an anatomical base. Joint rotations can therefore be expressed in the well-established terminology necessary for their clinical interpretation. Functional evaluation of patients affected by foot diseases has recently called for more detailed and non-invasive protocols for the description of foot joint rotations during gait. The proposed method can help clinicians to distinguish between normal and pathological pattern of foot joint rotations, and to quantitatively assess the restoration of normal function after treatment.

  3. The Benefits and Limitations of Using Ultrasonography to Supplement Anatomical Understanding

    ERIC Educational Resources Information Center

    Sweetman, Greg M.; Crawford, Gail; Hird, Kathryn; Fear, Mark W.

    2013-01-01

    Anatomical understanding is critical to medical education. With reduced teaching time and limited cadaver availability, it is important to investigate how best to utilize in vivo imaging to supplement anatomical understanding and better prepare medical graduates for the proliferation of point-of-care imaging in the future. To investigate whether…

  4. Effect of Anatomically Realistic Full-Head Model on Activation of Cortical Neurons in Subdural Cortical Stimulation—A Computational Study

    NASA Astrophysics Data System (ADS)

    Seo, Hyeon; Kim, Donghyeon; Jun, Sung Chan

    2016-06-01

    Electrical brain stimulation (EBS) is an emerging therapy for the treatment of neurological disorders, and computational modeling studies of EBS have been used to determine the optimal parameters for highly cost-effective electrotherapy. Recent notable growth in computing capability has enabled researchers to consider an anatomically realistic head model that represents the full head and complex geometry of the brain rather than the previous simplified partial head model (extruded slab) that represents only the precentral gyrus. In this work, subdural cortical stimulation (SuCS) was found to offer a better understanding of the differential activation of cortical neurons in the anatomically realistic full-head model than in the simplified partial-head models. We observed that layer 3 pyramidal neurons had comparable stimulation thresholds in both head models, while layer 5 pyramidal neurons showed a notable discrepancy between the models; in particular, layer 5 pyramidal neurons demonstrated asymmetry in the thresholds and action potential initiation sites in the anatomically realistic full-head model. Overall, the anatomically realistic full-head model may offer a better understanding of layer 5 pyramidal neuronal responses. Accordingly, the effects of using the realistic full-head model in SuCS are compelling in computational modeling studies, even though this modeling requires substantially more effort.

  5. Evaluation of the diagnostic yield of dental radiography and cone-beam computed tomography for the identification of anatomic landmarks in small to medium-sized brachycephalic dogs.

    PubMed

    Döring, Sophie; Arzi, Boaz; Barich, Catherine R; Hatcher, David C; Kass, Philip H; Verstraete, Frank J M

    2018-01-01

    OBJECTIVE To evaluate the diagnostic yield of dental radiography (Rad method) and 3 cone-beam CT (CBCT) methods for the identification of predefined anatomic landmarks in brachycephalic dogs. ANIMALS 19 client-owned brachycephalic dogs admitted for evaluation and treatment of dental disease. PROCEDURES 26 predefined anatomic landmarks were evaluated separately by use of the RAD method and 3 CBCT software modules (serial CBCT slices and custom cross sections, tridimensional rendering, and reconstructed panoramic views). A semiquantitative scoring system was used, and mean scores were calculated for each anatomic landmark and imaging method. The Friedman test was used to evaluate values for significant differences in diagnostic yield. For values that were significant, the Wilcoxon signed rank test was used with the Bonferroni-Holm multiple comparison adjustment to determine significant differences among each of the 6 possible pairs of diagnostic methods. RESULTS Differences of diagnostic yield among the Rad and 3 CBCT methods were significant for 19 of 26 anatomic landmarks. For these landmarks, Rad scores were significantly higher than scores for reconstructed panoramic views for 4 of 19 anatomic landmarks, but Rad scores were significantly lower than scores for reconstructed panoramic views for 8 anatomic landmarks, tridimensional rendering for 18 anatomic landmarks, and serial CBCT slices and custom cross sections for all 19 anatomic landmarks. CONCLUSIONS AND CLINICAL RELEVANCE CBCT methods were better suited than dental radiography for the identification of anatomic landmarks in brachycephalic dogs. Results of this study can serve as a basis for CBCT evaluation of dental disorders in brachycephalic dogs.

  6. Anatomics: the intersection of anatomy and bioinformatics

    PubMed Central

    Bard, Jonathan BL

    2005-01-01

    Computational resources are now using the tissue names of the major model organisms so that tissue-associated data can be archived in and retrieved from databases on the basis of developing and adult anatomy. For this to be done, the set of tissues in that organism (its anatome) has to be organized in a way that is computer-comprehensible. Indeed, such formalization is a necessary part of what is becoming known as systems biology, in which explanations of high-level biological phenomena are not only sought in terms of lower-level events, but are articulated within a computational framework. Lists of tissue names alone, however, turn out to be inadequate for this formalization because tissue organization is essentially hierarchical and thus cannot easily be put into tables, the natural format of relational databases. The solution now adopted is to organize the anatomy of each organism as a hierarchy of tissue names and linking relationships (e.g. the tibia is PART OF the leg, the tibia IS-A bone) within what are known as ontologies. In these, a unique ID is assigned to each tissue and this can be used within, for example, gene-expression databases to link data to tissue organization, and also used to query other data sources (interoperability), while inferences about the anatomy can be made within the ontology on the basis of the relationships. There are now about 15 such anatomical ontologies, many of which are linked to organism databases; these ontologies are now publicly available at the Open Biological Ontologies website (http://obo.sourceforge.net) from where they can be freely downloaded and viewed using standard tools. This review considers how anatomy is formalized within ontologies, together with the problems that have had to be solved for this to be done. It is suggested that the appropriate term for the analysis, computer formulation and use of the anatome is anatomics. PMID:15679867

  7. Retrieving high-resolution images over the Internet from an anatomical image database

    NASA Astrophysics Data System (ADS)

    Strupp-Adams, Annette; Henderson, Earl

    1999-12-01

    The Visible Human Data set is an important contribution to the national collection of anatomical images. To enhance the availability of these images, the National Library of Medicine has supported the design and development of a prototype object-oriented image database which imports, stores, and distributes high resolution anatomical images in both pixel and voxel formats. One of the key database modules is its client-server Internet interface. This Web interface provides a query engine with retrieval access to high-resolution anatomical images that range in size from 100KB for browser viewable rendered images, to 1GB for anatomical structures in voxel file formats. The Web query and retrieval client-server system is composed of applet GUIs, servlets, and RMI application modules which communicate with each other to allow users to query for specific anatomical structures, and retrieve image data as well as associated anatomical images from the database. Selected images can be downloaded individually as single files via HTTP or downloaded in batch-mode over the Internet to the user's machine through an applet that uses Netscape's Object Signing mechanism. The image database uses ObjectDesign's object-oriented DBMS, ObjectStore that has a Java interface. The query and retrieval systems has been tested with a Java-CDE window system, and on the x86 architecture using Windows NT 4.0. This paper describes the Java applet client search engine that queries the database; the Java client module that enables users to view anatomical images online; the Java application server interface to the database which organizes data returned to the user, and its distribution engine that allow users to download image files individually and/or in batch-mode.

  8. Renal Tumor Anatomic Complexity: Clinical Implications for Urologists.

    PubMed

    Joshi, Shreyas S; Uzzo, Robert G

    2017-05-01

    Anatomic tumor complexity can be objectively measured and reported using nephrometry. Various scoring systems have been developed in an attempt to correlate tumor complexity with intraoperative and postoperative outcomes. Nephrometry may also predict tumor biology in a noninvasive, reproducible manner. Other scoring systems can help predict surgical complexity and the likelihood of complications, independent of tumor characteristics. The accumulated data in this new field provide provocative evidence that objectifying anatomic complexity can consolidate reporting mechanisms and improve metrics of comparisons. Further prospective validation is needed to understand the full descriptive and predictive ability of the various nephrometry scores. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Control over structure-specific flexibility improves anatomical accuracy for point-based deformable registration in bladder cancer radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wognum, S.; Chai, X.; Hulshof, M. C. C. M.

    2013-02-15

    Purpose: Future developments in image guided adaptive radiotherapy (IGART) for bladder cancer require accurate deformable image registration techniques for the precise assessment of tumor and bladder motion and deformation that occur as a result of large bladder volume changes during the course of radiotherapy treatment. The aim was to employ an extended version of a point-based deformable registration algorithm that allows control over tissue-specific flexibility in combination with the authors' unique patient dataset, in order to overcome two major challenges of bladder cancer registration, i.e., the difficulty in accounting for the difference in flexibility between the bladder wall and tumormore » and the lack of visible anatomical landmarks for validation. Methods: The registration algorithm used in the current study is an extension of the symmetric-thin plate splines-robust point matching (S-TPS-RPM) algorithm, a symmetric feature-based registration method. The S-TPS-RPM algorithm has been previously extended to allow control over the degree of flexibility of different structures via a weight parameter. The extended weighted S-TPS-RPM algorithm was tested and validated on CT data (planning- and four to five repeat-CTs) of five urinary bladder cancer patients who received lipiodol injections before radiotherapy. The performance of the weighted S-TPS-RPM method, applied to bladder and tumor structures simultaneously, was compared with a previous version of the S-TPS-RPM algorithm applied to bladder wall structure alone and with a simultaneous nonweighted S-TPS-RPM registration of the bladder and tumor structures. Performance was assessed in terms of anatomical and geometric accuracy. The anatomical accuracy was calculated as the residual distance error (RDE) of the lipiodol markers and the geometric accuracy was determined by the surface distance, surface coverage, and inverse consistency errors. Optimal parameter values for the flexibility and bladder weight

  10. Control over structure-specific flexibility improves anatomical accuracy for point-based deformable registration in bladder cancer radiotherapy.

    PubMed

    Wognum, S; Bondar, L; Zolnay, A G; Chai, X; Hulshof, M C C M; Hoogeman, M S; Bel, A

    2013-02-01

    Future developments in image guided adaptive radiotherapy (IGART) for bladder cancer require accurate deformable image registration techniques for the precise assessment of tumor and bladder motion and deformation that occur as a result of large bladder volume changes during the course of radiotherapy treatment. The aim was to employ an extended version of a point-based deformable registration algorithm that allows control over tissue-specific flexibility in combination with the authors' unique patient dataset, in order to overcome two major challenges of bladder cancer registration, i.e., the difficulty in accounting for the difference in flexibility between the bladder wall and tumor and the lack of visible anatomical landmarks for validation. The registration algorithm used in the current study is an extension of the symmetric-thin plate splines-robust point matching (S-TPS-RPM) algorithm, a symmetric feature-based registration method. The S-TPS-RPM algorithm has been previously extended to allow control over the degree of flexibility of different structures via a weight parameter. The extended weighted S-TPS-RPM algorithm was tested and validated on CT data (planning- and four to five repeat-CTs) of five urinary bladder cancer patients who received lipiodol injections before radiotherapy. The performance of the weighted S-TPS-RPM method, applied to bladder and tumor structures simultaneously, was compared with a previous version of the S-TPS-RPM algorithm applied to bladder wall structure alone and with a simultaneous nonweighted S-TPS-RPM registration of the bladder and tumor structures. Performance was assessed in terms of anatomical and geometric accuracy. The anatomical accuracy was calculated as the residual distance error (RDE) of the lipiodol markers and the geometric accuracy was determined by the surface distance, surface coverage, and inverse consistency errors. Optimal parameter values for the flexibility and bladder weight parameters were determined

  11. The sensory territory of the lateral cutaneous nerve of the thigh as determined by anatomic dissections and ultrasound-guided blocks.

    PubMed

    Corujo, Alejandro; Franco, Carlo D; Williams, James M

    2012-01-01

    A femoral block sometimes fails to provide complete sensory anesthesia of the anterior aspect of middle and distal thigh, and a block of the lateral cutaneous nerve of the thigh (LCN) is often necessary to supplement it. The goal of this study was to demonstrate, both in the anatomy laboratory and in the clinical setting, a possible contribution of the LCN to the innervation of the anterior thigh. This was a prospective, observational study, including anatomic dissections and a clinical section in which 22 patients received an ultrasound-guided block of the LCN. The resulting area of anesthesia was determined 15 minutes later using pinprick examination. In 1 of 3 thigh dissections, we found a dominant LCN innervating most of the anterior aspect of the middle and distal thigh, areas that are usually attributed to the femoral nerve. In the clinical part of the study, 10 patients (45.5%) developed an area of anesthesia that extended to the medial aspect of the thigh and distally to the patella. Our results, coming from a small sample, seem to indicate that the LCN may contribute to the innervation of the anterior thigh in some cases. A block of the LCN could be considered when a femoral block has failed to produce the expected area of anesthesia.

  12. Two unusual anatomic variations create a diagnostic dilemma in distal ulnar nerve compression.

    PubMed

    Kiehn, Mark W; Derrick, Allison J; Iskandar, Bermans J

    2008-09-01

    Diagnosis of peripheral neuropathies is based upon patterns of functional deficits and electrodiagnostic testing. However, anatomic variations can lead to confounding patterns of physical and electrodiagnostic findings. Authors present a case of ulnar nerve compression due to a rare combination of anatomic variations, aberrant branching pattern, and FCU insertion at the wrist, which posed a diagnostic and therapeutic dilemma. The literature related to isolated distal ulnar motor neuropathy and anatomic variations of the ulnar nerve and adjacent structures is also reviewed. This case demonstrates how anatomic variations can complicate the interpretation of clinical and electrodiagnostic findings and underscores the importance of thorough exploration of the nerve in consideration for possible variations. (c) 2008 Wiley-Liss, Inc.

  13. Chronic ankle instability: Arthroscopic anatomical repair.

    PubMed

    Arroyo-Hernández, M; Mellado-Romero, M; Páramo-Díaz, P; García-Lamas, L; Vilà-Rico, J

    Ankle sprains are one of the most common injuries. Despite appropriate conservative treatment, approximately 20-40% of patients continue to have chronic ankle instability and pain. In 75-80% of cases there is an isolated rupture of the anterior talofibular ligament. A retrospective observational study was conducted on 21 patients surgically treated for chronic ankle instability by means of an arthroscopic anatomical repair, between May 2012 and January 2013. There were 15 men and 6 women, with a mean age of 30.43 years (range 18-48). The mean follow-up was 29 months (range 25-33). All patients were treated by arthroscopic anatomical repair of anterior talofibular ligament. Four (19%) patients were found to have varus hindfoot deformity. Associated injuries were present in 13 (62%) patients. There were 6 cases of osteochondral lesions, 3 cases of posterior ankle impingement syndrome, and 6 cases of peroneal pathology. All these injuries were surgically treated in the same surgical time. A clinical-functional study was performed using the American Orthopaedic Foot and Ankle Society (AOFAS) score. The mean score before surgery was 66.12 (range 60-71), and after surgery it increased up to a mean of 96.95 (range 90-100). All patients were able to return to their previous sport activity within a mean of 21.5 weeks (range 17-28). Complications were found in 3 (14%) patients. Arthroscopic anatomical ligament repair technique has excellent clinical-functional results with a low percentage of complications, and enables patients to return to their previous sport activity within a short period of time. Copyright © 2016 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.

  14. Parcellation of the human substantia nigra based on anatomical connectivity to the striatum☆

    PubMed Central

    Chowdhury, Rumana; Lambert, Christian; Dolan, Raymond J.; Düzel, Emrah

    2013-01-01

    Substantia nigra/ventral tegmental area (SN/VTA) subregions, defined by dopaminergic projections to the striatum, are differentially affected by health (e.g. normal aging) and disease (e.g. Parkinson's disease). This may have an impact on reward processing which relies on dopaminergic regions and circuits. We acquired diffusion tensor imaging (DTI) with probabilistic tractography in 30 healthy older adults to determine whether subregions of the SN/VTA could be delineated based on anatomical connectivity to the striatum. We found that a dorsomedial region of the SN/VTA preferentially connected to the ventral striatum whereas a more ventrolateral region connected to the dorsal striatum. These SN/VTA subregions could be characterised by differences in quantitative structural imaging parameters, suggesting different underlying tissue properties. We also observed that these connectivity patterns differentially mapped onto reward dependence personality trait. We show that tractography can be used to parcellate the SN/VTA into anatomically plausible and behaviourally meaningful compartments, an approach that may help future studies to provide a more fine-grained synopsis of pathological changes in the dopaminergic midbrain and their functional impact. PMID:23684858

  15. Immediate direct-to-implant breast reconstruction using anatomical implants.

    PubMed

    Kim, Sung-Eun; Jung, Dong-Woo; Chung, Kyu-Jin; Lee, Jun Ho; Kim, Tae Gon; Kim, Yong-Ha; Lee, Soo Jung; Kang, Su Hwan; Choi, Jung Eun

    2014-09-01

    In 2012, a new anatomic breast implant of form-stable silicone gel was introduced onto the Korean market. The intended use of this implant is in the area of aesthetic breast surgery, and many reports are promising. Thus far, however, there have been no reports on the use of this implant for breast reconstruction in Korea. We used this breast implant in breast reconstruction surgery and report our early experience. From November 2012 to April 2013, the Natrelle Style 410 form-stable anatomically shaped cohesive silicone gel-filled breast implant was used in 31 breasts of 30 patients for implant breast reconstruction with an acellular dermal matrix. Patients were treated with skin-sparing mastectomies followed by immediate breast reconstruction. The mean breast resection volume was 240 mL (range, 83-540 mL). The mean size of the breast implants was 217 mL (range, 125-395 mL). Breast shape outcomes were considered acceptable. Infection and skin thinning occurred in one patient each, and hematoma and seroma did not occur. Three cases of wound dehiscence occurred, one requiring surgical intervention, while the others healed with conservative treatment in one month. Rippling did not occur. So far, complications such as capsular contracture and malrotation of breast implant have not yet arisen. By using anatomic breast implants in breast reconstruction, we achieved satisfactory results with aesthetics better than those obtained with round breast implants. Therefore, we concluded that the anatomical implant is suitable for breast reconstruction.

  16. Live Donor Renal Anatomic Asymmetry and Post-Transplant Renal Function

    PubMed Central

    Tanriover, Bekir; Fernandez, Sonalis; Campenot, Eric S.; Newhouse, Jeffrey H.; Oyfe, Irina; Mohan, Prince; Sandikci, Burhaneddin; Radhakrishnan, Jai; Wexler, Jennifer J.; Carroll, Maureen A.; Sharif, Sairah; Cohen, David J.; Ratner, Lloyd E.; Hardy, Mark A.

    2014-01-01

    Background Relationship between live donor renal anatomic asymmetry and post-transplant recipient function has not been studied extensively. Methods We analyzed 96 live-kidney donors, who had anatomical asymmetry (>10% renal length and/or volume difference calculated from CT angiograms) and their matching recipients. Split function differences (SFD) were quantified with 99mTc-DMSA renography. Implantation biopsies at time-zero were semi-quantitatively scored. A comprehensive model utilizing donor renal volume adjusted to recipient weight (Vol/Wgt), SFD, and biopsy score was used to predict recipient estimated glomerular filtration rate (eGFR) at one-year. Primary analysis consisted of a logistic regression model of outcome (odds of developing eGFR>60ml/min/1.73 m2 at one-year), a linear regression model of outcome (predicting recipient eGFR at one-year, using the CKD-EPI formula), and a Monte Carlo simulation based on the linear regression model (N=10,000 iterations). Results In the study cohort, the mean Vol/Wgt and eGFR at one-year were 2.04 ml/kg and 60.4 ml/min/1.73m2, respectively. Volume and split ratios between two donor kidneys were strongly correlated (r=0.79, p-value<0.001). The biopsy scores among SFD categories (<5%, 5–10%, >10%) were not different (p=0.190). On multivariate models, only Vol/Wgt was significantly associated with higher odds of having eGFR>60ml/min/1.73 m2 (OR=8.94, 95% CI 2.47–32.25, p=0.001) and had a strong discriminatory power in predicting the risk of eGFR<60ml/min/1.73m2 at one-year (ROC curve=0.78, 95% CI 0.68–0.89). Conclusion In the presence of donor renal anatomic asymmetry, Vol/Wgt appears to be a major determinant of recipient renal function at one-year post-transplantation. Renography can be replaced with CT volume calculation in estimating split renal function. PMID:25719258

  17. Assessment of Anatomical Knowledge and Core Trauma Competency Vascular Skills.

    PubMed

    Granite, Guinevere; Pugh, Kristy; Chen, Hegang; Longinaker, Nyaradzo; Garofalo, Evan; Shackelford, Stacy; Shalin, Valerie; Puche, Adam; Pasley, Jason; Sarani, Babak; Henry, Sharon; Bowyer, Mark; Mackenzie, Colin

    2018-03-01

    Surgical residents express confidence in performing specific vascular exposures before training, but such self-reported confidence did not correlate with co-located evaluator ratings. This study reports residents' self-confidence evaluated before and after Advanced Surgical Skills for Exposure in Trauma (ASSET) cadaver-based training, and 12-18 mo later. We hypothesize that residents will better judge their own skill after ASSET than before when compared with evaluator ratings. Forty PGY2-7 surgical residents performed four procedures: axillary artery (AA), brachial artery (BA), femoral artery exposure and control (FA), and lower extremity fasciotomy (FAS) at the three evaluations. Using 5-point Likert scales, surgeons self-assessed their confidence in anatomical understanding and procedure performance after each procedure and evaluators rated each surgeon accordingly. For all the three evaluations, residents consistently rated their anatomical understanding (p < 0.04) and surgical performance (p < 0.03) higher than evaluators for both FA and FAS. Residents rated their anatomical understanding and surgical performance higher (p < 0.005) than evaluators for BA after training and up to 18 mo later. Only for third AA evaluation were there no rating differences. Residents overrate their anatomical understanding and performance abilities for BA, FA, and FAS even after performing the procedures and being debriefed three times in 18 mo.

  18. An anatomical and functional topography of human auditory cortical areas

    PubMed Central

    Moerel, Michelle; De Martino, Federico; Formisano, Elia

    2014-01-01

    While advances in magnetic resonance imaging (MRI) throughout the last decades have enabled the detailed anatomical and functional inspection of the human brain non-invasively, to date there is no consensus regarding the precise subdivision and topography of the areas forming the human auditory cortex. Here, we propose a topography of the human auditory areas based on insights on the anatomical and functional properties of human auditory areas as revealed by studies of cyto- and myelo-architecture and fMRI investigations at ultra-high magnetic field (7 Tesla). Importantly, we illustrate that—whereas a group-based approach to analyze functional (tonotopic) maps is appropriate to highlight the main tonotopic axis—the examination of tonotopic maps at single subject level is required to detail the topography of primary and non-primary areas that may be more variable across subjects. Furthermore, we show that considering multiple maps indicative of anatomical (i.e., myelination) as well as of functional properties (e.g., broadness of frequency tuning) is helpful in identifying auditory cortical areas in individual human brains. We propose and discuss a topography of areas that is consistent with old and recent anatomical post-mortem characterizations of the human auditory cortex and that may serve as a working model for neuroscience studies of auditory functions. PMID:25120426

  19. Anatomical Thin Titanium Mesh Plate Structural Optimization for Zygomatic-Maxillary Complex Fracture under Fatigue Testing.

    PubMed

    Wang, Yu-Tzu; Huang, Shao-Fu; Fang, Yu-Ting; Huang, Shou-Chieh; Cheng, Hwei-Fang; Chen, Chih-Hao; Wang, Po-Fang; Lin, Chun-Li

    2018-01-01

    This study performs a structural optimization of anatomical thin titanium mesh (ATTM) plate and optimal designed ATTM plate fabricated using additive manufacturing (AM) to verify its stabilization under fatigue testing. Finite element (FE) analysis was used to simulate the structural bending resistance of a regular ATTM plate. The Taguchi method was employed to identify the significance of each design factor in controlling the deflection and determine an optimal combination of designed factors. The optimal designed ATTM plate with patient-matched facial contour was fabricated using AM and applied to a ZMC comminuted fracture to evaluate the resting maxillary micromotion/strain under fatigue testing. The Taguchi analysis found that the ATTM plate required a designed internal hole distance to be 0.9 mm, internal hole diameter to be 1 mm, plate thickness to be 0.8 mm, and plate height to be 10 mm. The designed plate thickness factor primarily dominated the bending resistance up to 78% importance. The averaged micromotion (displacement) and strain of the maxillary bone showed that ZMC fracture fixation using the miniplate was significantly higher than those using the AM optimal designed ATTM plate. This study concluded that the optimal designed ATTM plate with enough strength to resist the bending effect can be obtained by combining FE and Taguchi analyses. The optimal designed ATTM plate with patient-matched facial contour fabricated using AM provides superior stabilization for ZMC comminuted fractured bone segments.

  20. Evaluation of marginal fit of 2 CAD-CAM anatomic contour zirconia crown systems and lithium disilicate glass-ceramic crown.

    PubMed

    Ji, Min-Kyung; Park, Ji-Hee; Park, Sang-Won; Yun, Kwi-Dug; Oh, Gye-Jeong; Lim, Hyun-Pil

    2015-08-01

    This study was to evaluate the marginal fit of two CAD-CAM anatomic contour zirconia crown systems compared to lithium disilicate glass-ceramic crowns. Shoulder and deep chamfer margin were formed on each acrylic resin tooth model of a maxillary first premolar. Two CAD-CAM systems (Prettau®Zirconia and ZENOSTAR®ZR translucent) and lithium disilicate glass ceramic (IPS e.max®press) crowns were made (n=16). Each crown was bonded to stone dies with resin cement (Rely X Unicem). Marginal gap and absolute marginal discrepancy of crowns were measured using a light microscope equipped with a digital camera (Leica DFC295) magnified by a factor of 100. Two-way analysis of variance (ANOVA) and post-hoc Tukey's HSD test were conducted to analyze the significance of crown marginal fit regarding the finish line configuration and the fabrication system. The mean marginal gap of lithium disilicate glass ceramic crowns (IPS e.max®press) was significantly lower than that of the CAD-CAM anatomic contour zirconia crown system (Prettau®Zirconia) (P<.05). Both fabrication systems and finish line configurations significantly influenced the absolute marginal discrepancy (P<.05). The lithium disilicate glass ceramic crown (IPS e.max®press) had significantly smaller marginal gap than the CAD-CAM anatomic contour zirconia crown system (Prettau®Zirconia). In terms of absolute marginal discrepancy, the CAD-CAM anatomic contour zirconia crown system (ZENOSTAR®ZR translucent) had under-extended margin, whereas the CAD-CAM anatomic contour zirconia crown system (Prettau®Zirconia) and lithium disilicate glass ceramic crowns (IPS e.max®press) had overextended margins.

  1. The maxillary second molar - anatomical variations (case report).

    PubMed

    Beshkenadze, E; Chipashvili, N

    2015-01-01

    To be acquainted with dental anatomical specificity is of great importance for dental endodontic treatment algorithm. The subject of present publication is 2 clinical cases of upper second molars, detailed characterization of, which is considered very important for enrichment of anatomical knowledge about dental anatomical variations. In one case, the reason for admission to the clinic of a 38-year-old woman was complains as of esthetic character as well as functional misbalance (disturbance of chewing function due to the damage of orthopedic construction). The patient indicated to the existence of coronary defects of large size aesthetic discomforts, damage and discolouration of old orthopedic construction (denture) in maxillary right molar area. According to the data obtained after clinical and visiographical examinations, chronic periodontitis of 17 teeth was identified as a result of incomplete endodontic treatment. According to the data obtained after clinical and visiographical examinations, the diagnosis of chronic periodontitis of 17 teeth was identified, tooth 17 with 2 roots and 2 canals. In the second clinical case, the reason for admission to the clinic of a 39-year-old woman was severe pain in the upper right molar area. The patient indicated to the caries on the tooth 17. After completion of proper survey clinical and visiographical examinations, acute pulpitis (K04.00) - with three roots and 4 canals was diagnosed. In both cases after the proper examinations and agreement with the patients a treatment plan envisaging: 17 teeth endodontic treatment, filling of caries defects and their preparation on one hand for orthopedic construction (denture) and on the other hand for restoration of anatomical integrity by light-cured composite, was scheduled. The present study is designed to prevent complications of endodontic treatment of the second molar, to optimize diagnosis and treatment algorithm, once again proving reliable information indicating to the

  2. A Reinforcement-Based Learning Paradigm Increases Anatomical Learning and Retention-A Neuroeducation Study.

    PubMed

    Anderson, Sarah J; Hecker, Kent G; Krigolson, Olave E; Jamniczky, Heather A

    2018-01-01

    In anatomy education, a key hurdle to engaging in higher-level discussion in the classroom is recognizing and understanding the extensive terminology used to identify and describe anatomical structures. Given the time-limited classroom environment, seeking methods to impart this foundational knowledge to students in an efficient manner is essential. Just-in-Time Teaching (JiTT) methods incorporate pre-class exercises (typically online) meant to establish foundational knowledge in novice learners so subsequent instructor-led sessions can focus on deeper, more complex concepts. Determining how best do we design and assess pre-class exercises requires a detailed examination of learning and retention in an applied educational context. Here we used electroencephalography (EEG) as a quantitative dependent variable to track learning and examine the efficacy of JiTT activities to teach anatomy. Specifically, we examined changes in the amplitude of the N250 and reward positivity event-related brain potential (ERP) components alongside behavioral performance as novice students participated in a series of computerized reinforcement-based learning modules to teach neuroanatomical structures. We found that as students learned to identify anatomical structures, the amplitude of the N250 increased and reward positivity amplitude decreased in response to positive feedback. Both on a retention and transfer exercise when learners successfully remembered and translated their knowledge to novel images, the amplitude of the reward positivity remained decreased compared to early learning. Our findings suggest ERPs can be used as a tool to track learning, retention, and transfer of knowledge and that employing the reinforcement learning paradigm is an effective educational approach for developing anatomical expertise.

  3. COMICS: Cartoon Visualization of Omics Data in Spatial Context Using Anatomical Ontologies

    PubMed Central

    2017-01-01

    COMICS is an interactive and open-access web platform for integration and visualization of molecular expression data in anatomograms of zebrafish, carp, and mouse model systems. Anatomical ontologies are used to map omics data across experiments and between an experiment and a particular visualization in a data-dependent manner. COMICS is built on top of several existing resources. Zebrafish and mouse anatomical ontologies with their controlled vocabulary (CV) and defined hierarchy are used with the ontoCAT R package to aggregate data for comparison and visualization. Libraries from the QGIS geographical information system are used with the R packages “maps” and “maptools” to visualize and interact with molecular expression data in anatomical drawings of the model systems. COMICS allows users to upload their own data from omics experiments, using any gene or protein nomenclature they wish, as long as CV terms are used to define anatomical regions or developmental stages. Common nomenclatures such as the ZFIN gene names and UniProt accessions are provided additional support. COMICS can be used to generate publication-quality visualizations of gene and protein expression across experiments. Unlike previous tools that have used anatomical ontologies to interpret imaging data in several animal models, including zebrafish, COMICS is designed to take spatially resolved data generated by dissection or fractionation and display this data in visually clear anatomical representations rather than large data tables. COMICS is optimized for ease-of-use, with a minimalistic web interface and automatic selection of the appropriate visual representation depending on the input data. PMID:29083911

  4. COMICS: Cartoon Visualization of Omics Data in Spatial Context Using Anatomical Ontologies.

    PubMed

    Travin, Dmitrii; Popov, Iaroslav; Guler, Arzu Tugce; Medvedev, Dmitry; van der Plas-Duivesteijn, Suzanne; Varela, Monica; Kolder, Iris C R M; Meijer, Annemarie H; Spaink, Herman P; Palmblad, Magnus

    2018-01-05

    COMICS is an interactive and open-access web platform for integration and visualization of molecular expression data in anatomograms of zebrafish, carp, and mouse model systems. Anatomical ontologies are used to map omics data across experiments and between an experiment and a particular visualization in a data-dependent manner. COMICS is built on top of several existing resources. Zebrafish and mouse anatomical ontologies with their controlled vocabulary (CV) and defined hierarchy are used with the ontoCAT R package to aggregate data for comparison and visualization. Libraries from the QGIS geographical information system are used with the R packages "maps" and "maptools" to visualize and interact with molecular expression data in anatomical drawings of the model systems. COMICS allows users to upload their own data from omics experiments, using any gene or protein nomenclature they wish, as long as CV terms are used to define anatomical regions or developmental stages. Common nomenclatures such as the ZFIN gene names and UniProt accessions are provided additional support. COMICS can be used to generate publication-quality visualizations of gene and protein expression across experiments. Unlike previous tools that have used anatomical ontologies to interpret imaging data in several animal models, including zebrafish, COMICS is designed to take spatially resolved data generated by dissection or fractionation and display this data in visually clear anatomical representations rather than large data tables. COMICS is optimized for ease-of-use, with a minimalistic web interface and automatic selection of the appropriate visual representation depending on the input data.

  5. Anatomic pathology laboratory information systems: a review.

    PubMed

    Park, Seung Lyung; Pantanowitz, Liron; Sharma, Gaurav; Parwani, Anil Vasdev

    2012-03-01

    The modern anatomic pathology laboratory depends on a reliable information infrastructure to register specimens, record gross and microscopic findings, regulate laboratory workflow, formulate and sign out report(s), disseminate them to the intended recipients across the whole health system, and support quality assurance measures. This infrastructure is provided by the Anatomical Pathology Laboratory Information Systems (APLIS), which have evolved over decades and now are beginning to support evolving technologies like asset tracking and digital imaging. As digital pathology transitions from "the way of the future" to "the way of the present," the APLIS continues to be one of the key effective enablers of the scope and practice of pathology. In this review, we discuss the evolution, necessary components, architecture and functionality of the APLIS that are crucial to today's practicing pathologist and address the demands of emerging trends on the future APLIS.

  6. 45 CFR 158.607 - Factors HHS uses to determine the amount of penalty.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... level of financial and other impacts on affected individuals. (3) Other factors as justice may require. ... 45 Public Welfare 1 2012-10-01 2012-10-01 false Factors HHS uses to determine the amount of... Civil Penalties § 158.607 Factors HHS uses to determine the amount of penalty. In determining the amount...

  7. 45 CFR 158.607 - Factors HHS uses to determine the amount of penalty.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... level of financial and other impacts on affected individuals. (3) Other factors as justice may require. ... 45 Public Welfare 1 2014-10-01 2014-10-01 false Factors HHS uses to determine the amount of... Civil Penalties § 158.607 Factors HHS uses to determine the amount of penalty. In determining the amount...

  8. 45 CFR 158.607 - Factors HHS uses to determine the amount of penalty.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... level of financial and other impacts on affected individuals. (3) Other factors as justice may require. ... 45 Public Welfare 1 2013-10-01 2013-10-01 false Factors HHS uses to determine the amount of... Civil Penalties § 158.607 Factors HHS uses to determine the amount of penalty. In determining the amount...

  9. Estimating anatomical wrist joint motion with a robotic exoskeleton.

    PubMed

    Rose, Chad G; Kann, Claudia K; Deshpande, Ashish D; O'Malley, Marcia K

    2017-07-01

    Robotic exoskeletons can provide the high intensity, long duration targeted therapeutic interventions required for regaining motor function lost as a result of neurological injury. Quantitative measurements by exoskeletons have been proposed as measures of rehabilitative outcomes. Exoskeletons, in contrast to end effector designs, have the potential to provide a direct mapping between human and robot joints. This mapping rests on the assumption that anatomical axes and robot axes are aligned well, and that movement within the exoskeleton is negligible. These assumptions hold well for simple one degree-of-freedom joints, but may not be valid for multi-articular joints with unique musculoskeletal properties such as the wrist. This paper presents an experiment comparing robot joint kinematic measurements from an exoskeleton to anatomical joint angles measured with a motion capture system. Joint-space position measurements and task-space smoothness metrics were compared between the two measurement modalities. The experimental results quantify the error between joint-level position measurements, and show that exoskeleton kinematic measurements preserve smoothness characteristics found in anatomical measures of wrist movements.

  10. Anatomical variations of uncinate process observed in chronic sinusitis.

    PubMed

    Tuli, Isha Preet; Sengupta, Subhabrata; Munjal, Sudeep; Kesari, Santosh Prasad; Chakraborty, Suvamoy

    2013-04-01

    Chronic Sinusitis, an extremely persistent illness, is surgically best treated by Functional Endoscopic Sinus Surgery. The ostiomeatal complex is the main area targeted and within it uncinate process is the first anatomical structure encountered. The significance of anatomical variations concerning age and sex of uncinate process in chronic sinusitis were evaluated. A prospective study on 50 patients of chronic sinusitis (100 uncinate processes) was done. The results were tabulated and analyzed using Statistical Package for Social Science (SPSS) 16.0. Type I superior attachment of uncinate process (67 %) was the most common variety in all ages and both sexes and a statistically significant relationship between Type I superior attachment of uncinate process and sex was found (p < 0.05). The typical uncinate process was most common (70 %) followed by medial deviation of the uncinate (24 %). This difference in occurrence was significant with respect to both age and sex (p < 0.05). Anatomical variations of uncinate process are not responsible for causing chronic sinusitis. Mere presence of these variations of uncinate is not an indication for FESS.

  11. Alterations in Anatomical Covariance in the Prematurely Born

    PubMed Central

    Scheinost, Dustin; Kwon, Soo Hyun; Lacadie, Cheryl; Vohr, Betty R.; Schneider, Karen C.; Papademetris, Xenophon; Constable, R. Todd; Ment, Laura R.

    2017-01-01

    Abstract Preterm (PT) birth results in long-term alterations in functional and structural connectivity, but the related changes in anatomical covariance are just beginning to be explored. To test the hypothesis that PT birth alters patterns of anatomical covariance, we investigated brain volumes of 25 PTs and 22 terms at young adulthood using magnetic resonance imaging. Using regional volumetrics, seed-based analyses, and whole brain graphs, we show that PT birth is associated with reduced volume in bilateral temporal and inferior frontal lobes, left caudate, left fusiform, and posterior cingulate for prematurely born subjects at young adulthood. Seed-based analyses demonstrate altered patterns of anatomical covariance for PTs compared with terms. PTs exhibit reduced covariance with R Brodmann area (BA) 47, Broca's area, and L BA 21, Wernicke's area, and white matter volume in the left prefrontal lobe, but increased covariance with R BA 47 and left cerebellum. Graph theory analyses demonstrate that measures of network complexity are significantly less robust in PTs compared with term controls. Volumes in regions showing group differences are significantly correlated with phonological awareness, the fundamental basis for reading acquisition, for the PTs. These data suggest both long-lasting and clinically significant alterations in the covariance in the PTs at young adulthood. PMID:26494796

  12. Increased anteversion of press-fit femoral stems compared with anatomic femur.

    PubMed

    Emerson, Roger H

    2012-02-01

    With contemporary canal-filling press-fit stems, there is no adjustability of stem position in the canal and therefore the canal anatomy determines stem version. Stem version will affect head/neck impingement, polyethylene wear from edge loading, and hip stability, but despite this, the postoperative version of a canal-filling press-fit stem is unclear. Is there a difference between the version of the nonoperated femur and the final version of a canal-filling press-fit femoral component? Could a difference create an alignment problem for the hip replacement? Sixty-four hips were studied with fluoroscopy and 46 nonarthritic and 41 arthritic hips were studied with MRI. A standardized fluoroscopic technique for determining preoperative and postoperative femoral version was developed with the patient supine on a fracture table undergoing supine total hip arthroplasty. To validate the methods, the results were compared with two selected series of axial MRI views of the hip comparing the version of the head with the version of the canal at the base of the neck. For the operated hips, the mean anatomic hip version was less than the stem version: 18.9° versus 27.0°. The difference on average was 8.1° of increased anteversion (SD, 7.4°). Both MRI series showed the femoral neck was more anteverted on average than the femoral head, thereby explaining the operative findings. With a canal-filling press-fit femoral component there is wide variation of postoperative component anteversion with most stems placed in increased anteversion compared with the anatomic head. The surgical technique may need to adjust for this if causing intraoperative impingement or instability.

  13. Advertising cadavers in the republic of letters: anatomical publications in the early modern Netherlands.

    PubMed

    Margócsy, Dániel

    2009-06-01

    This paper sketches how late seventeenth-century Dutch anatomists used printed publications to advertise their anatomical preparations, inventions and instructional technologies to an international clientele. It focuses on anatomists Frederik Ruysch (1638-1732) and Lodewijk de Bils (1624-69), inventors of two separate anatomical preparation methods for preserving cadavers and body parts in a lifelike state for decades or centuries. Ruysch's and de Bils's publications functioned as an 'advertisement' for their preparations. These printed volumes informed potential customers that anatomical preparations were aesthetically pleasing and scientifically important but did not divulge the trade secrets of the method of production. Thanks to this strategy of non-disclosure and advertisement, de Bils and Ruysch could create a well-working monopoly market of anatomical preparations. The 'advertising' rhetorics of anatomical publications highlight the potential dangers of equating the growth of print culture with the development of an open system of knowledge exchange.

  14. Biliary bacterial factors determine the path of gallstone formation.

    PubMed

    Stewart, Lygia; Grifiss, J McLeod; Jarvis, Gary A; Way, Lawrence W

    2006-11-01

    Bacteria cause pigment gallstones and can act as a nidus for cholesterol gallstone formation. Bacterial factors that facilitate gallstone formation include beta-glucuronidase (bG), phospholipase (PhL), and slime. The current study sought to determine whether bacterial factors influence the path of gallstone formation. A total of 382 gallstones were cultured and/or examined using scanning electron microscopy (SEM). Bacteria were tested for bG and slime production. Gallstone composition was determined using infrared spectrography. Ca-palmitate presence documented bacterial PhL production. Groups were identified based upon bacterial factors present: slime and bGPhL (slime/bGPhL), bGPhL only, and slime only. Influence of bacterial stone-forming factors on gallstone composition and morphology was analyzed. Bacteria were present in 75% of pigment, 76% of mixed, and 20% of cholesterol stones. Gallstones with bGPhL producing bacteria contained more pigment (71% vs. 26%, P < .0001). The slime/bGPhL group was associated (79%) with pigment stones, bGPhL was associated (56%) with mixed stones, while slime (or none) only was associated (67%) with cholesterol stones (P < .031, all comparisons). Bacterial properties determined the path of gallstone formation. Bacteria that produced all stone-forming factors promoted pigment stone formation, while those that produced only bGPhL promoted mixed stone formation. Bacteria that only produced slime lacked the ability to generate pigment solids, and consequently were more common in the centers of cholesterol stones. This shows how bacterial characteristics may govern the process of gallstone formation.

  15. Gross feature recognition of Anatomical Images based on Atlas grid (GAIA): Incorporating the local discrepancy between an atlas and a target image to capture the features of anatomic brain MRI.

    PubMed

    Qin, Yuan-Yuan; Hsu, Johnny T; Yoshida, Shoko; Faria, Andreia V; Oishi, Kumiko; Unschuld, Paul G; Redgrave, Graham W; Ying, Sarah H; Ross, Christopher A; van Zijl, Peter C M; Hillis, Argye E; Albert, Marilyn S; Lyketsos, Constantine G; Miller, Michael I; Mori, Susumu; Oishi, Kenichi

    2013-01-01

    We aimed to develop a new method to convert T1-weighted brain MRIs to feature vectors, which could be used for content-based image retrieval (CBIR). To overcome the wide range of anatomical variability in clinical cases and the inconsistency of imaging protocols, we introduced the Gross feature recognition of Anatomical Images based on Atlas grid (GAIA), in which the local intensity alteration, caused by pathological (e.g., ischemia) or physiological (development and aging) intensity changes, as well as by atlas-image misregistration, is used to capture the anatomical features of target images. As a proof-of-concept, the GAIA was applied for pattern recognition of the neuroanatomical features of multiple stages of Alzheimer's disease, Huntington's disease, spinocerebellar ataxia type 6, and four subtypes of primary progressive aphasia. For each of these diseases, feature vectors based on a training dataset were applied to a test dataset to evaluate the accuracy of pattern recognition. The feature vectors extracted from the training dataset agreed well with the known pathological hallmarks of the selected neurodegenerative diseases. Overall, discriminant scores of the test images accurately categorized these test images to the correct disease categories. Images without typical disease-related anatomical features were misclassified. The proposed method is a promising method for image feature extraction based on disease-related anatomical features, which should enable users to submit a patient image and search past clinical cases with similar anatomical phenotypes.

  16. Basic anatomical and physiological data for use in radiological protection: reference values. A report of age- and gender-related differences in the anatomical and physiological characteristics of reference individuals. ICRP Publication 89.

    PubMed

    2002-01-01

    This report presents detailed information on age- and gender-related differences in the anatomical and physiological characteristics of reference individuals. These reference values provide needed input to prospective dosimetry calculations for radiation protection purposes for both workers and members of the general public. The purpose of this report is to consolidate and unify in one publication, important new information on reference anatomical and physiological values that has become available since Publication 23 was published by the ICRP in 1975. There are two aspects of this work. The first is to revise and extend the information in Publication 23 as appropriate. The second is to provide additional information on individual variation among grossly normal individuals resulting from differences in age, gender, race, or other factors. This publication collects, unifies, and expands the updated ICRP reference values for the purpose of providing a comprehensive and consistent set of age- and gender-specific reference values for anatomical and physiological features of the human body pertinent to radiation dosimetry. The reference values given in this report are based on: (a) anatomical and physiological information not published before by the ICRP; (b) recent ICRP publications containing reference value information; and (c) information in Publication 23 that is still considered valid and appropriate for radiation protection purposes. Moving from the past emphasis on 'Reference Man', the new report presents a series of reference values for both male and female subjects of six different ages: newborn, 1 year, 5 years, 10 years, 15 years, and adult. In selecting reference values, the Commission has used data on Western Europeans and North Americans because these populations have been well studied with respect to antomy, body composition, and physiology. When appropriate, comparisons are made between the chosen reference values and data from several Asian populations

  17. [Non-metastatic clear cell renal cancer: dependence of the tumour stage on clinico-anatomic and morphologic factors; prognostic value of macro- and karyometric characteristics].

    PubMed

    Iurin, A G

    2010-01-01

    Non-metastatic clear-cell renal cancer: dependence of the tumour stage on clinico-anatomic and morphologic factors; prognostic value of macro- and karyometric characteristics Sankt Peterburg Pathology Bureau, Sankt Peterburg It was shown based on multivariate regression analysis that pT1a3bN0MO stages of non-metastatic clear-cell renal cancer significantly correlate not only with the tumor size and invasion into the fatty tissue and/or renal vein but also with the invasion into the renal capsule and with the mean maximum diameter and mean nucleus area of tumor cells. There was no correlation of clear-cell renal cancer stages with tumor proliferative activity, gene p53 mutation, oncosuppressor gene PTEN expression, fraction of tumour clear-cell component, and such clinical characteristics as patients' sex, age, and body mass index. Taking into account statistically significant differences between the patients' survival rates, the regression equations developed in this work may be used for the prediction of disease outcome.

  18. [Persian terminology in Arabic anatomical texts].

    PubMed

    Barcia Goyanes, J J

    1995-01-01

    The article explains the meaning of some Iranian technical words, which appear in anatomical Arab works. They are interesting, not only because they are nearly unknown, but also because they are evidence of the influence of Iranian culture on the rise of Arabian scientific medicine, and so an encouragement to further investigation on this subject.

  19. Wood anatomical analysis of Alnus incana and Betula pendula injured by a debris-flow event.

    PubMed

    Arbellay, Estelle; Stoffel, Markus; Bollschweiler, Michelle

    2010-10-01

    Vessel chronologies in ring-porous species have been successfully employed in the past to extract the climate signal from tree rings. Environmental signals recorded in vessels of ring-porous species have also been used in previous studies to reconstruct discrete events of drought, flooding and insect defoliation. However, very little is known about the ability of diffuse-porous species to record environmental signals in their xylem cells. Moreover, time series of wood anatomical features have only rarely been used to reconstruct former geomorphic events. This study was therefore undertaken to characterize the wood anatomical response of diffuse-porous Alnus incana (L.) Moench and Betula pendula Roth to debris-flow-induced wounding. Tree microscopic response to wounding was assessed through the analysis of wood anatomical differences between injured rings formed in the debris-flow event year and uninjured rings formed in the previous year. The two ring types were examined close and opposite to the injury in order to determine whether wound effects on xylem cells decrease with increasing tangential distance from the injury. Image analysis was used to measure vessel parameters as well as fiber and parenchyma cell (FPC) parameters. The results of this study indicate that injured rings are characterized by smaller vessels as compared with uninjured rings. By contrast, FPC parameters were not found to significantly differ between injured and uninjured rings. Vessel and FPC parameters mainly remained constant with increasing tangential distance from the injury, except for a higher proportion of vessel lumen area opposite to the injury within A. incana. This study highlights the existence of anatomical tree-ring signatures-in the form of smaller vessels-related to past debris-flow activity and addresses a new methodological approach to date injuries inflicted on trees by geomorphic processes.

  20. [The meninges, an anatomical point of view].

    PubMed

    Sakka, L; Chazal, J

    2005-03-01

    The meninges correspond to an anatomical concept. For the morphologist, the microscopic organization, the hypothetical presence of a subdural space, the nature of the interface between the deep meningeal layer and the nervous parenchyma in the perivascular spaces are the central issues. For the clinician, dynamic aspects of cerebrospinal fluid flow, secretion, and resorption are essential factors with practical consequences in terms of disease and patient management. Comparative anatomy, embryology, and organogenesis provide an interesting perspective for the descriptive and functional anatomy of the meninges. Usually considered as protective membranes, the meninges play a prominent role in the development and maintenance of the central nervous system. The meninges are in constant evolution, from their formation to senescence. The meninges present three layers in children and adults: the dura mater, the arachnoid and the pia mater. The cerebrospinal fluid is secreted by the choroid plexuses, flows through the ventricles and the subarachnoid space, and is absorbed by arachnoid granulations. Other sites of secretion and resorption are suggested by comparative anatomy and human embryology and organogenesis.

  1. Fast correspondences search in anatomical trees

    NASA Astrophysics Data System (ADS)

    dos Santos, Thiago R.; Gergel, Ingmar; Meinzer, Hans-Peter; Maier-Hein, Lena

    2010-03-01

    Registration of multiple medical images commonly comprises the steps feature extraction, correspondences search and transformation computation. In this paper, we present a new method for a fast and pose independent search of correspondences using as features anatomical trees such as the bronchial system in the lungs or the vessel system in the liver. Our approach scores the similarities between the trees' nodes (bifurcations) taking into account both, topological properties extracted from their graph representations and anatomical properties extracted from the trees themselves. The node assignment maximizes the global similarity (sum of the scores of each pair of assigned nodes), assuring that the matches are distributed throughout the trees. Furthermore, the proposed method is able to deal with distortions in the data, such as noise, motion, artifacts, and problems associated with the extraction method, such as missing or false branches. According to an evaluation on swine lung data sets, the method requires less than one second on average to compute the matching and yields a high rate of correct matches compared to state of the art work.

  2. Anatomical Correlates of Non-Verbal Perception in Dementia Patients

    PubMed Central

    Lin, Pin-Hsuan; Chen, Hsiu-Hui; Chen, Nai-Ching; Chang, Wen-Neng; Huang, Chi-Wei; Chang, Ya-Ting; Hsu, Shih-Wei; Hsu, Che-Wei; Chang, Chiung-Chih

    2016-01-01

    Purpose: Patients with dementia who have dissociations in verbal and non-verbal sound processing may offer insights into the anatomic basis for highly related auditory modes. Methods: To determine the neuronal networks on non-verbal perception, 16 patients with Alzheimer’s dementia (AD), 15 with behavior variant fronto-temporal dementia (bv-FTD), 14 with semantic dementia (SD) were evaluated and compared with 15 age-matched controls. Neuropsychological and auditory perceptive tasks were included to test the ability to compare pitch changes, scale-violated melody and for naming and associating with environmental sound. The brain 3D T1 images were acquired and voxel-based morphometry (VBM) was used to compare and correlated the volumetric measures with task scores. Results: The SD group scored the lowest among 3 groups in pitch or scale-violated melody tasks. In the environmental sound test, the SD group also showed impairment in naming and also in associating sound with pictures. The AD and bv-FTD groups, compared with the controls, showed no differences in all tests. VBM with task score correlation showed that atrophy in the right supra-marginal and superior temporal gyri was strongly related to deficits in detecting violated scales, while atrophy in the bilateral anterior temporal poles and left medial temporal structures was related to deficits in environmental sound recognition. Conclusions: Auditory perception of pitch, scale-violated melody or environmental sound reflects anatomical degeneration in dementia patients and the processing of non-verbal sounds are mediated by distinct neural circuits. PMID:27630558

  3. The anatomical location and laterality of orbital cavernous haemangiomas.

    PubMed

    McNab, Alan A; Selva, Dinesh; Hardy, Thomas G; O'Donnell, Brett

    2014-10-01

    To determine the anatomical location and laterality of orbital cavernous haemangiomas (OCH). Retrospective case series. The records of 104 patients with OCH were analyzed. The anatomical location of each OCH defined by the location of a point at the centre of the lesion, and its laterality. There were 104 patients included in the study. No patient had more than one lesion. Sixteen (15.4%) were located in the anterior third of the orbit, 74 (71.2%) were in the middle third, and 14 (13.5%) in the posterior third. In the middle third, 10 of 74 (13.5%) were extraconal and 64 intraconal (86.5%), with 30 of 64 (46.9%) middle third intraconal lesions lying lateral to the optic nerve. Of 104 lesions, 56 (53.8%) were left sided, showing a trend towards a predilection for the left side (p = 0.065). If data from other published series which included data on laterality is added to our own data and analysed, 270 of 468 (57.7%) OCH occurred in the left orbit (p < 0.005). OCH may occur at almost any location within the orbit. The commonest location is the middle third of the orbit, in the intraconal space lateral to the optic nerve. This may reflect an origin of these lesions from the arterial side of the circulation, as there are more small arteries in the intraconal space lateral to the optic nerve than in other locations. A predilection for the left orbit remains unexplained.

  4. Quantitative anatomical study of taste buds in fungiform papillae of young and old Fischer rats.

    PubMed

    Mistretta, C M; Oakley, I A

    1986-05-01

    To determine if differences in neural taste responses relate to taste bud loss in old age, taste buds were counted in fungiform papillae of Fischer 344 rats aged 4 to 6 months, 20 to 24 months, and 30 to 37 months. Papillae anterior to the intermolar eminence on one half of the tongue were examined in serial sections. Presence or absence of a taste bud was noted and taste bud diameter was measured. Average percentages of papillae that contained a taste bud in the three groups were 99.6, 99.3, and 94.7%. This is a significant age-related difference but actual number of taste buds lost in the oldest rats was small. Taste bud diameter did not differ with age and general anatomical characteristics of buds were similar in all groups. Thus, anatomical observations on taste bud maintenance in rats over a wide age range, coupled with neurophysiological data, demonstrate that the integrity of the peripheral gustatory system is not altered greatly in old age.

  5. Reduction of Mental Distress in the Dissection Course by Introducing the Body Donor Experience through Anatomical Demonstrations of Organ Systems

    ERIC Educational Resources Information Center

    Bockers, Anja; Baader, Christoph; Fassnacht, Ulrich Kai; Ochsner, Wolfgang; Bockers, Tobias Maria

    2012-01-01

    The practice of dissection teaches students not only the foundations of anatomical knowledge but also encourages the development of professional competencies. Yet, the dissection of cadavers in the gross anatomy course can be a stress factor for medical students. There are a minor proportion of students who demonstrate strong emotional reactions…

  6. Mobilization of the rectum: anatomic concepts and the bookshelf revisited.

    PubMed

    Chapuis, Pierre; Bokey, Les; Fahrer, Marius; Sinclair, Gael; Bogduk, Nikolai

    2002-01-01

    Sound surgical technique is based on accurate anatomic knowledge. In surgery for cancer, the anatomy of the perirectal fascia and the retrorectal plane is the basis for correct mobilization of the rectum to ensure clear surgical margins and to minimize the risk of local recurrence. This review of the literature on the perirectal fascia is based on a translation of the original description by Thoma Jonnesco and a later account by Wilhelm Waldeyer. The Jonnesco description, first published in 1896 in French, is compared with the German account of 1899. These were critically analyzed in the context of our own and other techniques of mobilizing the rectum. Mobilization of the rectum for cancer can be performed along anatomic planes with minimal blood loss, preservation of the pelvic autonomic nerves and a low prevalence of local recurrence. Different techniques including total mesorectal excision are based on the same anatomic principles, however, popular words have been used to replace accepted, established terminology. In particular, the description of total mesorectal excision has been confusing because of its emphasis on the words "total" and "mesorectum." The use of the word "mesorectum" anatomically is inaccurate and the implication that total excision of all the perirectal fat contained within the perirectal fascia "en bloc" in all patients with rectal cancer will minimize local recurrence remains contentious.

  7. Anatomical characteristics of southern pine stemwood

    Treesearch

    Elaine T. Howard; Floyd G. Manwiller

    1968-01-01

    To obtain a definitive description of the wood and anatomy of all 10 species of southern pine, juvenile, intermediate, and mature wood was sampled at three heights in one tree of each species and examined under a light microscope. Photographs and three-dimensional drawings were made to illustrate the morphology. No significant anatomical differences were found...

  8. HPV Vaccine Effective at Multiple Anatomic Sites

    Cancer.gov

    A new study from NCI researchers finds that the HPV vaccine protects young women from infection with high-risk HPV types at the three primary anatomic sites where persistent HPV infections can cause cancer. The multi-site protection also was observed at l

  9. Anterolateral ligament anatomy: a comparative anatomical study.

    PubMed

    Ingham, Sheila Jean McNeill; de Carvalho, Rogerio Teixeira; Martins, Cesar A Q; Lertwanich, Pisit; Abdalla, Rene Jorge; Smolinski, Patrick; Lovejoy, C Owen; Fu, Freddie H

    2017-04-01

    Some anatomical studies have indicated that the anterolateral ligament (ALL) of the knee is distinct ligamentous structure in humans. The purpose of this study is to compare the lateral anatomy of the knee among human and various animal specimens. Fifty-eight fresh-frozen knee specimens, from 24 different animal species, were used for this anatomical study. The same researchers dissected all the specimens in this study, and dissections were performed in a careful and standardized manner. An ALL was not found in any of the 58 knees dissected. Another interesting finding in this study is that some primate species (the prosimians: the red and black and white lemurs) have two LCLs. The clinical relevance of this study is the lack of isolation of the ALL as a unique structure in animal species. Therefore, precaution is recommended before assessing the need for surgery to reconstruct the ALL as a singular ligament.

  10. The prognostic value of functional and anatomical parameters for the selection of patients receiving yttrium-90 microspheres for the treatment of liver cancer

    NASA Astrophysics Data System (ADS)

    Mesoloras, Geraldine

    Yttrium-90 (90Y) microsphere therapy is being utilized as a treatment option for patients with primary and metastatic liver cancer due to its ability to target tumors within the liver. The success of this treatment is dependent on many factors, including the extent and type of disease and the nature of prior treatments received. Metabolic activity, as determined by PET imaging, may correlate with the number of viable cancer cells and reflect changes in viable cancer cell volume. However, contouring of PET images by hand is labor intensive and introduces an element of irreproducibility into the determination of functional target/tumor volume (FTV). A computer-assisted method to aid in the automatic contouring of FTV has the potential to substantially improve treatment individualization and outcome assessment. Commercial software to determine FTV in FDG-avid primary and metastatic liver tumors has been evaluated and optimized. Volumes determined using the automated technique were compared to those from manually drawn contours identified using the same cutoff in the standard uptake value (SUV). The reproducibility of FTV is improved through the introduction of an optimal threshold value determined from phantom experiments. Application of the optimal threshold value from the phantom experiments to patient scans was in good agreement with hand-drawn determinations of the FTV. It is concluded that computer-assisted contouring of the FTV for primary and metastatic liver tumors improves reproducibility and increases accuracy, especially when combined with the selection of an optimal SUV threshold determined from phantom experiments. A method to link the pre-treatment assessment of functional (PET based) and anatomical (CT based) parameters to post-treatment survival and time to progression was evaluated in 22 patients with colorectal cancer liver metastases treated using 90Y microspheres and chemotherapy. The values for pre-treatment parameters that were the best

  11. Anatomic, histologic, and two-dimensional-echocardiographic evaluation of mitral valve anatomy in dogs.

    PubMed

    Borgarelli, Michele; Tursi, Massimiliano; La Rosa, Giuseppe; Savarino, Paolo; Galloni, Marco

    2011-09-01

    To compare echocardiographic variables of dogs with postmortem anatomic measurements and histologic characteristics of the mitral valve (MV). 21 cardiologically normal dogs. The MV was measured echocardiographically by use of the right parasternal 5-chamber long-axis view. Dogs were euthanized, and anatomic measurements of the MV annulus (MVa) were performed at the level of the left circumflex coronary artery. Mitral valve leaflets (MVLs) and chordae tendineae were measured. Structure of the MVLs was histologically evaluated in 3 segments (proximal, middle, and distal). Echocardiographic measurements of MVL length did not differ significantly from anatomic measurements. A positive correlation was detected between body weight and MVa area. There was a negative correlation between MVa area and the percentage by which the MVL area exceeded the MVa area. Anterior MVLs had a significantly higher number of chordae tendineae than did posterior MVLs. Histologically, layering of MVLs was less preserved in the distal segment, whereas the muscular component and adipose tissue were significantly more diffuse in the proximal and middle segments. The MV in cardiologically normal dogs had wide anatomic variability. Anatomic measurements of MVL length were correlated with echocardiographic measurements.

  12. A practical workflow for making anatomical atlases for biological research.

    PubMed

    Wan, Yong; Lewis, A Kelsey; Colasanto, Mary; van Langeveld, Mark; Kardon, Gabrielle; Hansen, Charles

    2012-01-01

    The anatomical atlas has been at the intersection of science and art for centuries. These atlases are essential to biological research, but high-quality atlases are often scarce. Recent advances in imaging technology have made high-quality 3D atlases possible. However, until now there has been a lack of practical workflows using standard tools to generate atlases from images of biological samples. With certain adaptations, CG artists' workflow and tools, traditionally used in the film industry, are practical for building high-quality biological atlases. Researchers have developed a workflow for generating a 3D anatomical atlas using accessible artists' tools. They used this workflow to build a mouse limb atlas for studying the musculoskeletal system's development. This research aims to raise the awareness of using artists' tools in scientific research and promote interdisciplinary collaborations between artists and scientists. This video (http://youtu.be/g61C-nia9ms) demonstrates a workflow for creating an anatomical atlas.

  13. [Association of three anatomical variants of the anterior cerebral circulation].

    PubMed

    Reyes-Soto, Gervith; Pérez-Cruz, Julio; Delgado-Reyes, Luis; Ortega-Gutiérrez, César; Téllez-Palacios, Daniela

    2012-01-01

    As part of a study of the microsurgical anatomy of the pericallosal artery, we describe one brain with three unusual anatomical variants. From the autopsy of a 45 year-old female, we extracted the brain and all the arterial blood vessels were washed off with saline solution to be injected afterwards with red latex. The brain was then immersed in 10% formalin for two months. Finally, we dissected and measured the internal carotid artery segments, using a digital Vernier caliper under a Carl Zeiss OPMI surgical microscope with magnification of 6x up to 40x. The brain's weight was 1250 grams and three rare anatomical variants were found: 1) right accessory middle cerebral artery (ACMA-d), 2) right bihemispheric anterior cerebral artery (ACABihem-d), 3) median artery of the corpus callosum (AMCC). The association of the anatomical variations described previously is inconstant; furthermore, their appearance in a single case is rare.

  14. Assessment of anatomical knowledge: Approaches taken by higher education institutions.

    PubMed

    Choudhury, Bipasha; Freemont, Anthony

    2017-04-01

    Assessment serves the primary function of determining a student's competence in a subject. Several different assessment formats are available for assessing anatomical skills, knowledge and understanding and, as assessment can drive learning, a careful selection of assessments can help to engender the correct deep learning facility required of the safe clinical practitioner. The aim of this review was to survey the published literature to see whether higher education institutions are taking an andragogical approach to assessment. Five databases (EMBASE, ERIC, Medline, PubMed, and Web of Knowledge) were searched using standardized search terms with two limits applied (English language, and 2000 to the present). Among the 2,094 papers found, 32 were deemed suitable for this review. Current literature on assessment can be categorized into the following themes: assessment driven learning, types of assessments, frequency of assessments, and use of images in assessments. The consensus is to use a variety of methods, written and practical, to assess anatomical knowledge and skill in different domains. Institutions aim for different levels of Bloom's taxonomy for students at similar stages of their medical degree. Formative assessments are used widely, in differing formats, with mostly good effects on the final examination grade. In conclusion, a wide variety of assessments, each aimed at a different level of Bloom's taxonomy, are used by different institutions. Clin. Anat. 30:290-299, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  15. Anatomical and phenological implications of the relationship between Schinus polygama (Cav.) (Cabrera) and the galling insect Calophya rubra (Blanchard).

    PubMed

    Guedes, L M; Aguilera, N; Ferreira, B G; Becerra, J; Hernández, V; Isaias, R M S

    2018-05-01

    The success of galling insects could be determined by synchronisation with host plant phenology and climate conditions, ensuring suitable oviposition sites for gall induction and food resources for their survival. The anatomical, histochemical and phenological synchronisation strategies between Calophya rubra (Blanchard) (Hemiptera: Psylloidea) and its host, the evergreen plant Schinus polygama (Cav.) (Cabrera) (Anacardiaceae), in the Mediterranean climate of southern Chile was evaluated and compared to that of the congeneric C. cf. duvauae (Scott) from Brazil and closely related host plant S. engleri in a subtropical climate. Anatomical, histometric, histochemical and vegetative phenology studies of the stem and galls were conducted from June 2015 to December 2016. Based on the anatomical, histometric and histochemical analysis, the conical stem gall traits imply gains over the non-galled stem toward the galling insect survival, but the maintenance of phellem, secretory ducts and pith indicate conservative developmental traits that cannot be manipulated by C. rubra. Our results indicate that the conditions of the Mediterranean climate zone limit C. rubra immature activity during unfavourable periods, probably determining a diapause period and a univoltine life cycle, which are peculiarities of the S. polygama- C. rubra system. The synchronisation between development and seasonality confers peculiarities to the S. polygama- C. rubra system in the Mediterranean climate zone. © 2018 German Society for Plant Sciences and The Royal Botanical Society of the Netherlands.

  16. Learning-based stochastic object models for characterizing anatomical variations

    NASA Astrophysics Data System (ADS)

    Dolly, Steven R.; Lou, Yang; Anastasio, Mark A.; Li, Hua

    2018-03-01

    It is widely known that the optimization of imaging systems based on objective, task-based measures of image quality via computer-simulation requires the use of a stochastic object model (SOM). However, the development of computationally tractable SOMs that can accurately model the statistical variations in human anatomy within a specified ensemble of patients remains a challenging task. Previously reported numerical anatomic models lack the ability to accurately model inter-patient and inter-organ variations in human anatomy among a broad patient population, mainly because they are established on image data corresponding to a few of patients and individual anatomic organs. This may introduce phantom-specific bias into computer-simulation studies, where the study result is heavily dependent on which phantom is used. In certain applications, however, databases of high-quality volumetric images and organ contours are available that can facilitate this SOM development. In this work, a novel and tractable methodology for learning a SOM and generating numerical phantoms from a set of volumetric training images is developed. The proposed methodology learns geometric attribute distributions (GAD) of human anatomic organs from a broad patient population, which characterize both centroid relationships between neighboring organs and anatomic shape similarity of individual organs among patients. By randomly sampling the learned centroid and shape GADs with the constraints of the respective principal attribute variations learned from the training data, an ensemble of stochastic objects can be created. The randomness in organ shape and position reflects the learned variability of human anatomy. To demonstrate the methodology, a SOM of an adult male pelvis is computed and examples of corresponding numerical phantoms are created.

  17. Patterns of multisite pain and associations with risk factors

    PubMed Central

    Coggon, David; Ntani, Georgia; Palmer, Keith T.; Felli, Vanda E.; Harari, Raul; Barrero, Lope H.; Felknor, Sarah A.; Gimeno, David; Cattrell, Anna; Vargas-Prada, Sergio; Bonzini, Matteo; Solidaki, Eleni; Merisalu, Eda; Habib, Rima R.; Sadeghian, Farideh; Masood Kadir, M.; Warnakulasuriya, Sudath S.P.; Matsudaira, Ko; Nyantumbu, Busisiwe; Sim, Malcolm R.; Harcombe, Helen; Cox, Ken; Marziale, Maria H.; Sarquis, Leila M.; Harari, Florencia; Freire, Rocio; Harari, Natalia; Monroy, Magda V.; Quintana, Leonardo A.; Rojas, Marianela; Salazar Vega, Eduardo J.; Harris, E. Clare; Serra, Consol; Martinez, J. Miguel; Delclos, George; Benavides, Fernando G.; Carugno, Michele; Ferrario, Marco M.; Pesatori, Angela C.; Chatzi, Leda; Bitsios, Panos; Kogevinas, Manolis; Oha, Kristel; Sirk, Tuuli; Sadeghian, Ali; Peiris-John, Roshini J.; Sathiakumar, Nalini; Wickremasinghe, A. Rajitha; Yoshimura, Noriko; Kelsall, Helen L.; Hoe, Victor C.W; Urquhart, Donna M.; Derrett, Sarah; McBride, David; Herbison, Peter; Gray, Andrew

    2013-01-01

    To explore definitions for multisite pain, and compare associations with risk factors for different patterns of musculoskeletal pain, we analysed cross-sectional data from the Cultural and Psychosocial Influences on Disability (CUPID) study. The study sample comprised 12,410 adults aged 20–59 years from 47 occupational groups in 18 countries. A standardised questionnaire was used to collect information about pain in the past month at each of 10 anatomical sites, and about potential risk factors. Associations with pain outcomes were assessed by Poisson regression, and characterised by prevalence rate ratios (PRRs). Extensive pain, affecting 6–10 anatomical sites, was reported much more frequently than would be expected if the occurrence of pain at each site were independent (674 participants vs 41.9 expected). In comparison with pain involving only 1–3 sites, it showed much stronger associations (relative to no pain) with risk factors such as female sex (PRR 1.6 vs 1.1), older age (PRR 2.6 vs 1.1), somatising tendency (PRR 4.6 vs 1.3), and exposure to multiple physically stressing occupational activities (PRR 5.0 vs 1.4). After adjustment for number of sites with pain, these risk factors showed no additional association with a distribution of pain that was widespread according to the frequently used American College of Rheumatology criteria. Our analysis supports the classification of pain at multiple anatomical sites simply by the number of sites affected, and suggests that extensive pain differs importantly in its associations with risk factors from pain that is limited to only a small number of anatomical sites. PMID:23727463

  18. Alterations in Anatomical Covariance in the Prematurely Born.

    PubMed

    Scheinost, Dustin; Kwon, Soo Hyun; Lacadie, Cheryl; Vohr, Betty R; Schneider, Karen C; Papademetris, Xenophon; Constable, R Todd; Ment, Laura R

    2017-01-01

    Preterm (PT) birth results in long-term alterations in functional and structural connectivity, but the related changes in anatomical covariance are just beginning to be explored. To test the hypothesis that PT birth alters patterns of anatomical covariance, we investigated brain volumes of 25 PTs and 22 terms at young adulthood using magnetic resonance imaging. Using regional volumetrics, seed-based analyses, and whole brain graphs, we show that PT birth is associated with reduced volume in bilateral temporal and inferior frontal lobes, left caudate, left fusiform, and posterior cingulate for prematurely born subjects at young adulthood. Seed-based analyses demonstrate altered patterns of anatomical covariance for PTs compared with terms. PTs exhibit reduced covariance with R Brodmann area (BA) 47, Broca's area, and L BA 21, Wernicke's area, and white matter volume in the left prefrontal lobe, but increased covariance with R BA 47 and left cerebellum. Graph theory analyses demonstrate that measures of network complexity are significantly less robust in PTs compared with term controls. Volumes in regions showing group differences are significantly correlated with phonological awareness, the fundamental basis for reading acquisition, for the PTs. These data suggest both long-lasting and clinically significant alterations in the covariance in the PTs at young adulthood. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  19. The relationship between anatomically correct electric and magnetic field dosimetry and publishe delectric and magnetic field exposure limits.

    PubMed

    Kavet, Robert; Dovan, Thanh; Reilly, J Patrick

    2012-12-01

    Electric and magnetic field exposure limits published by International Commission for Non-Ionizing Radiation Protection and Institute of Electrical and Electronics Engineers are aimed at protection against adverse electrostimulation, which may occur by direct coupling to excitable tissue and, in the case of electric fields, through indirect means associated with surface charge effects (e.g. hair vibration, skin sensations), spark discharge and contact current. For direct coupling, the basic restriction (BR) specifies the not-to-be-exceeded induced electric field. The key results of anatomically based electric and magnetic field dosimetry studies and the relevant characteristics of excitable tissue were first identified. This permitted us to assess the electric and magnetic field exposure levels that induce dose in tissue equal to the basic restrictions, and the relationships of those exposure levels to the limits now in effect. We identify scenarios in which direct coupling of electric fields to peripheral nerve could be a determining factor for electric field limits.

  20. Long-range population dynamics of anatomically defined neocortical networks

    PubMed Central

    Chen, Jerry L; Voigt, Fabian F; Javadzadeh, Mitra; Krueppel, Roland; Helmchen, Fritjof

    2016-01-01

    The coordination of activity across neocortical areas is essential for mammalian brain function. Understanding this process requires simultaneous functional measurements across the cortex. In order to dissociate direct cortico-cortical interactions from other sources of neuronal correlations, it is furthermore desirable to target cross-areal recordings to neuronal subpopulations that anatomically project between areas. Here, we combined anatomical tracers with a novel multi-area two-photon microscope to perform simultaneous calcium imaging across mouse primary (S1) and secondary (S2) somatosensory whisker cortex during texture discrimination behavior, specifically identifying feedforward and feedback neurons. We find that coordination of S1-S2 activity increases during motor behaviors such as goal-directed whisking and licking. This effect was not specific to identified feedforward and feedback neurons. However, these mutually projecting neurons especially participated in inter-areal coordination when motor behavior was paired with whisker-texture touches, suggesting that direct S1-S2 interactions are sensory-dependent. Our results demonstrate specific functional coordination of anatomically-identified projection neurons across sensory cortices. DOI: http://dx.doi.org/10.7554/eLife.14679.001 PMID:27218452

  1. A Reinforcement-Based Learning Paradigm Increases Anatomical Learning and Retention—A Neuroeducation Study

    PubMed Central

    Anderson, Sarah J.; Hecker, Kent G.; Krigolson, Olave E.; Jamniczky, Heather A.

    2018-01-01

    In anatomy education, a key hurdle to engaging in higher-level discussion in the classroom is recognizing and understanding the extensive terminology used to identify and describe anatomical structures. Given the time-limited classroom environment, seeking methods to impart this foundational knowledge to students in an efficient manner is essential. Just-in-Time Teaching (JiTT) methods incorporate pre-class exercises (typically online) meant to establish foundational knowledge in novice learners so subsequent instructor-led sessions can focus on deeper, more complex concepts. Determining how best do we design and assess pre-class exercises requires a detailed examination of learning and retention in an applied educational context. Here we used electroencephalography (EEG) as a quantitative dependent variable to track learning and examine the efficacy of JiTT activities to teach anatomy. Specifically, we examined changes in the amplitude of the N250 and reward positivity event-related brain potential (ERP) components alongside behavioral performance as novice students participated in a series of computerized reinforcement-based learning modules to teach neuroanatomical structures. We found that as students learned to identify anatomical structures, the amplitude of the N250 increased and reward positivity amplitude decreased in response to positive feedback. Both on a retention and transfer exercise when learners successfully remembered and translated their knowledge to novel images, the amplitude of the reward positivity remained decreased compared to early learning. Our findings suggest ERPs can be used as a tool to track learning, retention, and transfer of knowledge and that employing the reinforcement learning paradigm is an effective educational approach for developing anatomical expertise. PMID:29467638

  2. Living AnatoME: Teaching and Learning Musculoskeletal Anatomy through Yoga and Pilates

    ERIC Educational Resources Information Center

    McCulloch, Carrie; Marango, Stephanie Pieczenik; Friedman, Erica S.; Laitman, Jeffrey T.

    2010-01-01

    Living AnatoME, a program designed in 2004 by two medical students in conjunction with the Director of Anatomy, teaches musculoskeletal anatomy through yoga and Pilates. Previously offered as an adjunct to the Gross Anatomy course in 2007, Living AnatoME became an official part of the curriculum. Previous research conducted on the program…

  3. Automatic anatomical segmentation of the liver by separation planes

    NASA Astrophysics Data System (ADS)

    Boltcheva, Dobrina; Passat, Nicolas; Agnus, Vincent; Jacob-Da, Marie-Andrée, , Col; Ronse, Christian; Soler, Luc

    2006-03-01

    Surgical planning in oncological liver surgery is based on the location of the 8 anatomical segments according to Couinaud's definition and tumors inside these structures. The detection of the boundaries between the segments is then the first step of the preoperative planning. The proposed method, devoted to binary images of livers segmented from CT-scans, has been designed to delineate these segments. It automatically detects a set of landmarks using a priori anatomical knowledge and differential geometry criteria. These landmarks are then used to position the Couinaud's segments. Validations performed on 7 clinical cases tend to prove that the method is reliable for most of these separation planes.

  4. Influence of anatomical location on CT numbers in cone beam computed tomography.

    PubMed

    Oliveira, Matheus L; Tosoni, Guilherme M; Lindsey, David H; Mendoza, Kristopher; Tetradis, Sotirios; Mallya, Sanjay M

    2013-04-01

    To assess the influence of anatomical location on computed tomography (CT) numbers in mid- and full field of view (FOV) cone beam computed tomography (CBCT) scans. Polypropylene tubes with varying concentrations of dipotassium hydrogen phosphate (K₂HPO₄) solutions (50-1200 mg/mL) were imaged within the incisor, premolar, and molar dental sockets of a human skull phantom. CBCT scans were acquired using the NewTom 3G and NewTom 5G units. The CT numbers of the K₂HPO₄ phantoms were measured, and the relationship between CT numbers and K₂HPO₄ concentration was examined. The measured CT numbers of the K₂HPO₄ phantoms were compared between anatomical sites. At all six anatomical locations, there was a strong linear relationship between CT numbers and K₂HPO₄ concentration (R(2)>0.93). However, the absolute CT numbers varied considerably with the anatomical location. The relationship between CT numbers and object density is not uniform through the dental arch on CBCT scans. Copyright © 2013 Elsevier Inc. All rights reserved.

  5. Femoral tunnel enlargement after anatomic ACL reconstruction: a biological problem?

    PubMed

    Silva, Alcindo; Sampaio, Ricardo; Pinto, Elisabete

    2010-09-01

    Tunnel enlargement after anterior cruciate ligament (ACL) reconstruction may compromise revision surgery. The cause of this tunnel enlargement is not yet fully understood, but it is thought to be multifactorial, with biomechanical and biological factors playing a role. Tunnel enlargement has been described particularly in patients who underwent ACL reconstruction with hamstring tendons with extracortical fixation devices. The purpose of our study was to evaluate prospectively with magnetic resonance imaging (MRI) the changes in femoral tunnel diameter following arthroscopic anatomic ACL reconstruction with hamstring tendons. At 3-month post-op, all tunnels had enlarged compared to the diameter of the drill and most tunnels enlarged more in the midsection than at the aperture. In the posterolateral tunnels, the entrance increased 16% in diameter and the middle of the tunnel increased 30% in diameter. In the anteromedial femoral tunnels, the tunnels enlarged 14% at the aperture and 35% in the midsection. All femoral tunnels enlarged and most of them enlarged in a fusiform manner. The biological factors explain better our findings than the mechanical theory, although mechanical factors may play a role and the cortical bone at the entrance of the tunnel may modify the way tunnels respond to mechanical stress.

  6. Lumbar artery perforators: an anatomical study based on computed tomographic angiography imaging.

    PubMed

    Sommeling, Casper Emile; Colebunders, Britt; Pardon, Heleen E; Stillaert, Filip B; Blondeel, Phillip N; van Landuyt, Koenraad

    2017-08-01

    The free lumbar artery perforator flap has recently been introduced as a potentially valuable option for autologous breast reconstruction in a subset of patients. Up to date, few anatomical studies, exploring the lumbar region as a donor site for perforator- based flaps, have been conducted. An anatomical study of the position of the dominant lumbar artery perforator was performed, using the preoperative computed tomographic angiography images of 24 autologous breast reconstruction patients. In total, 61 dominant perforators were determined, 28 on the left and 33 on the right side. A radiologist defined the position of the perforator as coordinates in an xy-grid. Dominant perforators were shown to originate from the lumbar arteries at the level of lumbar vertebrae three or four. Remarkably, approximately 85% of these lumbar artery perforators enter the skin at 7-10 cm lateral from the midline (mean left 8.6 cm, right 8.2 cm). This study concludes a rather constant position of the dominant perforator. Therefore, preoperative-computed tomographic angiography is not always essential to find this perforator and Doppler ultrasound could be considered as an alternative, thereby carefully assessing all advantages and disadvantages inherent to either of these imaging methods.

  7. Brain Anatomical Network and Intelligence

    PubMed Central

    Li, Jun; Qin, Wen; Li, Kuncheng; Yu, Chunshui; Jiang, Tianzi

    2009-01-01

    Intuitively, higher intelligence might be assumed to correspond to more efficient information transfer in the brain, but no direct evidence has been reported from the perspective of brain networks. In this study, we performed extensive analyses to test the hypothesis that individual differences in intelligence are associated with brain structural organization, and in particular that higher scores on intelligence tests are related to greater global efficiency of the brain anatomical network. We constructed binary and weighted brain anatomical networks in each of 79 healthy young adults utilizing diffusion tensor tractography and calculated topological properties of the networks using a graph theoretical method. Based on their IQ test scores, all subjects were divided into general and high intelligence groups and significantly higher global efficiencies were found in the networks of the latter group. Moreover, we showed significant correlations between IQ scores and network properties across all subjects while controlling for age and gender. Specifically, higher intelligence scores corresponded to a shorter characteristic path length and a higher global efficiency of the networks, indicating a more efficient parallel information transfer in the brain. The results were consistently observed not only in the binary but also in the weighted networks, which together provide convergent evidence for our hypothesis. Our findings suggest that the efficiency of brain structural organization may be an important biological basis for intelligence. PMID:19492086

  8. Anatomic partial nephrectomy: technique evolution.

    PubMed

    Azhar, Raed A; Metcalfe, Charles; Gill, Inderbir S

    2015-03-01

    Partial nephrectomy provides equivalent long-term oncologic and superior functional outcomes as radical nephrectomy for T1a renal masses. Herein, we review the various vascular clamping techniques employed during minimally invasive partial nephrectomy, describe the evolution of our partial nephrectomy technique and provide an update on contemporary thinking about the impact of ischemia on renal function. Recently, partial nephrectomy surgical technique has shifted away from main artery clamping and towards minimizing/eliminating global renal ischemia during partial nephrectomy. Supported by high-fidelity three-dimensional imaging, novel anatomic-based partial nephrectomy techniques have recently been developed, wherein partial nephrectomy can now be performed with segmental, minimal or zero global ischemia to the renal remnant. Sequential innovations have included early unclamping, segmental clamping, super-selective clamping and now culminating in anatomic zero-ischemia surgery. By eliminating 'under-the-gun' time pressure of ischemia for the surgeon, these techniques allow an unhurried, tightly contoured tumour excision with point-specific sutured haemostasis. Recent data indicate that zero-ischemia partial nephrectomy may provide better functional outcomes by minimizing/eliminating global ischemia and preserving greater vascularized kidney volume. Contemporary partial nephrectomy includes a spectrum of surgical techniques ranging from conventional-clamped to novel zero-ischemia approaches. Technique selection should be tailored to each individual case on the basis of tumour characteristics, surgical feasibility, surgeon experience, patient demographics and baseline renal function.

  9. Zero ischemia anatomical partial nephrectomy: a novel approach.

    PubMed

    Gill, Inderbir S; Patil, Mukul B; Abreu, Andre Luis de Castro; Ng, Casey; Cai, Jie; Berger, Andre; Eisenberg, Manuel S; Nakamoto, Masahiko; Ukimura, Osamu; Goh, Alvin C; Thangathurai, Duraiyah; Aron, Monish; Desai, Mihir M

    2012-03-01

    We present a novel concept of zero ischemia anatomical robotic and laparoscopic partial nephrectomy. Our technique primarily involves anatomical vascular microdissection and preemptive control of tumor specific, tertiary or higher order renal arterial branch(es) using neurosurgical aneurysm micro-bulldog clamps. In 58 consecutive patients the majority (70%) had anatomically complex tumors including central (67%), hilar (26%), completely intrarenal (23%), pT1b (18%) and solitary kidney (7%). Data were prospectively collected and analyzed from an institutional review board approved database. Of 58 cases undergoing zero ischemia robotic (15) or laparoscopic (43) partial nephrectomy, 57 (98%) were completed without hilar clamping. Mean tumor size was 3.2 cm, mean ± SD R.E.N.A.L. score 7.0 ± 1.9, C-index 2.9 ± 2.4, operative time 4.4 hours, blood loss 206 cc and hospital stay 3.9 days. There were no intraoperative complications. Postoperative complications (22.8%) were low grade (Clavien grade 1 to 2) in 19.3% and high grade (Clavien grade 3 to 5) in 3.5%. All patients had negative cancer surgical margins (100%). Mean absolute and percent change in preoperative vs 4-month postoperative serum creatinine (0.2 mg/dl, 18%), estimated glomerular filtration rate (-11.4 ml/minute/1.73 m(2), 13%), and ipsilateral kidney function on radionuclide scanning at 6 months (-10%) correlated with mean percent kidney excised intraoperatively (18%). Although 21% of patients received a perioperative blood transfusion, no patient had acute or delayed renal hemorrhage, or lost a kidney. The concept of zero ischemia robotic and laparoscopic partial nephrectomy is presented. This anatomical vascular microdissection of the artery first and then tumor allows even complex tumors to be excised without hilar clamping. Global surgical renal ischemia is unnecessary for the majority of patients undergoing robotic and laparoscopic partial nephrectomy at our institution. Copyright © 2012 American

  10. Factors Determining Success in Youth Judokas

    PubMed Central

    Krstulović, Saša; Caput, Petra Đapić

    2017-01-01

    Abstract The aim of this study was to compare two models of determining factors for success in judo. The first model (Model A) included testing motor abilities of high-level Croatian judokas in the cadet age category. The sample in Model A consisted of 71 male and female judokas aged 16 ± 0.6 years who were divided into four subsamples according to sex and weight category. The second model (Model B) consisted of interviewing 40 top-level judo experts on the importance of motor abilities for cadets’ success in judo. According to Model A, the greatest impact on the criterion variable of success in males and females of heavier weight categories were variables assessing maximum strength, coordination and jumping ability. In the lighter weight male categories, the highest correlation with the criterion variable of success was the variable assessing agility. However, in the lighter weight female categories, the greatest impact on success had the variable assessing muscular endurance. In Model B, specific endurance was crucial for success in judo, while flexibility was the least important, regardless of sex and weight category. Spearman’s rank correlation coefficients showed that there were no significant correlations in the results obtained in Models A and B for all observed subsamples. Although no significant correlations between the factors for success obtained through Models A and B were found, common determinants of success, regardless of the applied model, were identified. PMID:28469759

  11. Surface anatomy and anatomical planes in the adult turkish population.

    PubMed

    Uzun, C; Atman, E D; Ustuner, E; Mirjalili, S A; Oztuna, D; Esmer, T S

    2016-03-01

    Surface anatomy and anatomical planes are widely used in education and clinical practice. The planes are largely derived from cadaveric studies and their projections on the skin show discrepancies between and within anatomical reference textbooks. In this study, we reassessed the accuracy of common thoracic and abdominopelvic anatomical planes using computed tomography (CT) imaging in the live adult Turkish population. After patients with distorting pathologies had been excluded, CT images of 150 supine patients at the end tidal inspiration were analyzed. Sternal angle, transpyloric, subcostal, supracristal and pubic crest planes and their relationships to anatomical structures were established by dual consensus. The tracheal bifurcation, azygos vein/superior vena cava (SVC) junction and pulmonary bifurcation were usually below the sternal angle while the concavity of the aortic arch was generally within the plane. The tip of the tenth rib, the superior mesenteric artery and the portal vein were usually within the transpyloric plane while the renal hila and the fundus of the gallbladder were below it. The inferior mesenteric artery was below the subcostal plane and the aortic bifurcation was below the supracristal plane in most adults. Projectional surface anatomy is fundamental to medical education and clinical practice. Modern cross-sectional imaging techniques allow large groups of live patients to be examined. Classic textbook information regarding anatomy needs to be reviewed and updated using the data gathered from these recent studies, taking ethnic differences into consideration. © 2015 Wiley Periodicals, Inc.

  12. Factors determining poor prognostic outcomes following diabetic hand infections

    PubMed Central

    Ince, Bilsev; Dadaci, Mehmet; Arslan, Abdullah; Altuntas, Zeynep; Evrenos, Mustafa Kursat; Fatih Karsli, Mehmet

    2015-01-01

    Background and Objective: Hand ulcers are seen in a small percentage of patients with diabetes. The predisposing factors of diabetic hand varies between different countries. However, the effects of predisposing factors on prognosis are not clear in diabetic hand infections. In this study, our aim was to determine the effects of predisposing factors on poor prognostic outcomes in patients with diabetes mellitus. Methods: Thirty-four patients with diabetes mellitus who were treated and followed up for a hand infection in between 2008 and 2014 were investigated retrospectively. Patients were evaluated according to predisposing factors defined in the literature that included disease period, age, gender, admission time, presence of neuropathy, smoking habits, HbA1c levels at admission time, peripheral vascular disease, end-stage renal disease (ESRD), and trauma. Death and minor/major amputation cases during treatment were defined as poor prognosis. Results: Patients who had ESRD, peripheral neuropathy, or an HbA1c level greater than 10% had significantly higher amputation rates. Conclusions: Peripheral neuropathy, ESRD, and HbA1c levels greater than 10% at the time of admission were determined as poor prognosis criteria for diabetic hand treatment. PMID:26150838

  13. Mortimer Frank, Johann Ludwig Choulant, and the history of anatomical illustration.

    PubMed

    Feibel, Robert M

    2018-01-01

    Mortimer Frank (1874-1919) was an ophthalmologist in Chicago, Illinois. He published a number of papers on the history of medicine, and was secretary of the Chicago Society of the History of Medicine and editor of their Bulletin. His major contribution to the history of medicine relates to the history of anatomical illustration. The classic book on that subject had been published in 1852 in German by the physician and historian, Johann Ludwig Choulant (1791-1861). However, by Frank's time this text was both out dated and out of print. Frank took on the tremendous project of translating Choulant's German text into English as History and Bibliography of Anatomic Illustration in Its Relation to Anatomic Science and The Graphic Arts. He improved Choulant's text with the results of his and other scholars' research, greatly enlarging the text. Frank supplemented the original book with a biography of Choulant, essays on anatomists not considered in the original text, and an essay on the history of anatomical illustration prior to those authors discussed by Choulant. This book, now referred to as Choulant/Frank, has been reprinted several times, and is still useful as a reference in this field, though some of its research is now dated.

  14. Systemic Review of Anatomic Single- Versus Double-Bundle Anterior Cruciate Ligament Reconstruction: Does Femoral Tunnel Drilling Technique Matter?

    PubMed

    Zhang, Yang; Xu, Caiqi; Dong, Shiqui; Shen, Peng; Su, Wei; Zhao, Jinzhong

    2016-09-01

    To provide an up-to-date assessment of the difference between anatomic double-bundle anterior cruciate ligament (ACL) reconstruction (DB-ACLR) and anatomic single-bundle ACL reconstruction (SB-ACLR). We hypothesized that anatomic SB-ACLR using independent femoral drilling technique would be able to achieve kinematic stability as with anatomic DB-ACLR. A comprehensive Internet search was performed to identify all therapeutic trials of anatomic DB-ACLR versus anatomic SB-ACLR. Only clinical studies of Level I and II evidence were included. The comparative outcomes were instrument-measured anterior laxity, Lachman test, pivot shift, clinical outcomes including objective/subjective International Knee Documentation Committee (IKDC) score, Lysholm score, Tegner activity scale and complication rates of extension/flexion deficits, graft failure, and early osteoarthritis. Subgroup analyses were performed for femoral tunnel drilling techniques including independent drilling and transtibial (TT) drilling. Twenty-two clinical trials of 2,261 anatomically ACL-reconstructed patients were included in the meta-analysis. Via TT drilling technique, anatomic DB-ACLR led to improved instrument-measured anterior laxity with a standard mean difference (SMD) of -0.42 (95% confidence interval [CI] = -0.81 to -0.02), less rotational instability measured by pivot shift (SMD = 2.76, 95% CI = 1.24 to 6.16), and higher objective IKDC score with odds ratio (OR) of 2.28 (95% CI = 1.19 to 4.36). Via independent drilling technique, anatomic DB-ACLR yielded better pivot shift (SMD = 2.04, 95% CI = 1.36 to 3.05). Anatomic DB-ACLR also revealed statistical significance in subjective IKDC score compared with anatomic SB-ACLR (SMD = 0.27, 95% CI = 0.05 to 0.49). Anatomic DB-ACLR showed better anterior and rotational stability and higher objective IKDC score than anatomic SB-ACLR via TT drilling technique. Via independent drilling technique, however, anatomic DB-ACLR only showed superiority

  15. Radiographic evaluation of anatomical variables in maxilla and mandible in relation to dental implant placement.

    PubMed

    Chandra, Poornima; Govindaraju, Poornima; Chowdhary, Ramesh

    2016-01-01

    Oral rehabilitation using implants is rapidly replacing tooth supported prostheses. The success of implants is largely dependent on the quality and quantity of alveolar bone. In this study, we assessed the location of limiting anatomical structures and the amount of alveolar bone available for implant placement. Six hundred digital panoramic radiographs (300 males and 300 females) of dentate patients aged between 15-60 years were selected from the archives. The radiographs were subdivided into 3 groups with age interval of 15 years. Then the location of mental foramen, anterior loop, mandibular canal and maxillary sinus was determined. The amount of bone available was measured in both maxilla and mandible in the premolar and molar regions. The mental foramen was most commonly located at the apex of the second premolar in both the genders. The anterior loop was more readily visible in the younger age group. The amount of bone available in the premolar and molar region of the mandible is nearly the same, while more bone is available in the premolar region of the maxilla. The location and morphology of anatomical structures of the jaws vary not only in different populations but also within the same population. The amount of bone available also showed variations in the same population and in the same individual on the right and left sides. The limiting anatomical structures govern the amount of bone available for possible implant placement.

  16. Risk Factors as Major Determinants of Resilience: A Replication Study.

    PubMed

    Eshel, Yohanan; Kimhi, Shaul; Lahad, Mooli; Leykin, Dmitry; Goroshit, Marina

    2018-03-16

    The present study was conducted in the context of current concerns about replication in psychological research. It claims that risk factors should be regarded as an integral part of the definition of individual resilience, which should be defined in terms of the balance between individual strength or protective factors, and individual vulnerability or risk factors (IND-SVR). Five independent samples, including 3457 Israeli participants, were employed to determine the effects of resilience promoting and resilience suppressing variables on the IND-SVR index of resilience, and on its two components: recovery from adversity, and distress symptoms. Five path analyses were employed for determining the role of distress symptoms as a measure of psychological resilience, as compared to other indices of this resilience. Results indicated the major role of risk factors (distress symptoms) as an integral component of resilience. This role was generally replicated in the five investigated samples. Risk factors are legitimate, valid, and useful parts of the definition of psychological resilience. Resilience research has shifted away from studying individual risk factors to investigating the process through which individuals overcome the hardships they experience. The present data seem to suggest that this shift should be reexamined.

  17. Perihilar Glissonian Approach for Anatomical Parenchymal Sparing Liver Resections: Technical Aspects: The Taping Game.

    PubMed

    Figueroa, Rodrigo; Laurenzi, Andrea; Laurent, Alexis; Cherqui, Daniel

    2018-03-01

    To present technical details for central hepatectomy and right anterior and posterior sectionectomies using perihilar Glissonian approach for anatomical delineation and selective inflow occlusion. Central tumors and those deeply located in the right liver may require extensive resections because of their proximity to major vascular structures. In such cases, anatomical more limited resections such as central hepatectomy or sectionectomies may provide an alternative to extensive surgery by assuring both parenchymal sparing and suitable oncologic resection. We present the global concept for performing a perihilar Glissonian approach and its application to each individual anatomical procedure. This includes detailed descriptions, illustrations, and videos demonstrating the technique. This technique was applied since 1991 for anatomical parenchymal resections including central hepatectomy (resection of segments 4, 5, and 8), right anterior sectionectomy (resection of segments 5 and 8), and right posterior sectionectomy (resection of segments 6 and 7). The feasibility rate of the Glissonian approach was 88%. Perihilar Glissonian approach is a safe and reproducible technique that enables anatomical parenchymal preserving liver resections for selected central and right-sided deeply located tumors.

  18. Anatomic and Histological Investigation of the Anterolateral Capsular Complex in the Fetal Knee.

    PubMed

    Sabzevari, Soheil; Rahnemai-Azar, Amir Ata; Albers, Marcio; Linde, Monica; Smolinski, Patrick; Fu, Freddie H

    2017-05-01

    There is currently disagreement with regard to the presence of a distinct ligament in the anterolateral capsular complex of the knee and its role in the pivot-shift mechanism and rotatory laxity of the knee. To investigate the anatomic and histological properties of the anterolateral capsular complex of the fetal knee to determine whether there exists a distinct ligamentous structure running from the lateral femoral epicondyle inserting into the anterolateral tibia. Descriptive laboratory study. Twenty-one unpaired, fresh fetal lower limbs, gestational age 18 to 22 weeks, were used for anatomic investigation. Two experienced orthopaedic surgeons performed the anatomic dissection using loupes (magnification ×3.5). Attention was focused on the anterolateral and lateral structures of the knee. After the skin and superficial fascia were removed, the iliotibial band was carefully separated from underlying structures. The anterolateral capsule was then examined under internal and external rotation and varus-valgus manual loading and at different knee flexion angles for the presence of any ligamentous structures. Eight additional unpaired, fetal lower limbs, gestational age 11 to 23 weeks, were used for histological analysis. This study was not able to prove the presence of a distinct capsular or extracapsular ligamentous structure in the anterolateral capsular complex area. The presence of the fibular collateral ligament, a distal attachment of the biceps femoris, the entire lateral capsule, the iliotibial band, and the popliteus tendon in the anterolateral and lateral area of the knee was confirmed in all the samples. Histological analysis of the anterolateral capsule revealed a loose, hypocellular connective tissue with less organized collagen fibers compared with ligament and tendinous structures. The main finding of this study was that the presence of a distinct ligamentous structure in the anterolateral complex is not supported from a developmental point of view

  19. Understanding ontogenetic trajectories of indirect defence: ecological and anatomical constraints in the production of extrafloral nectaries

    PubMed Central

    Villamil, Nora; Márquez-Guzmán, Judith; Boege, Karina

    2013-01-01

    Background and Aims Early ontogenetic stages of myrmecophytic plants are infrequently associated with ants, probably due to constraints on the production of rewards. This study reports for the first time the anatomical and histological limitations constraining the production of extrafloral nectar in young plants, and the implications that the absence of protective ants imposes for plants early during their ontogeny are discussed. Methods Juvenile, pre-reproductive and reproductive plants of Turnera velutina were selected in a natural population and their extrafloral nectaries (EFNs) per leaf were quantified. The anatomical and morphological changes in EFNs during plant ontogeny were studied using scanning electron and light microscopy. Extrafloral nectar volume and sugar concentration were determined as well as the number of patrolling ants. Key Results Juvenile plants were unable to secrete or contain nectar. Pre-reproductive plants secreted and contained nectar drops, but the highest production was achieved at the reproductive stage when the gland is fully cup-shaped and the secretory epidermis duplicates. No ants were observed in juvenile plants, and reproductive individuals received greater ant patrolling than pre-reproductive individuals. The issue of the mechanism of extrafloral nectar release in T. velutina was solved given that we found an anatomical, transcuticular pore that forms a channel-like structure and allows nectar to flow outward from the gland. Conclusions Juvenile stages had no ant protection against herbivores probably due to resource limitation but also due to anatomical constraints. The results are consistent with the growth-differentiation balance hypothesis. As plants age, they increase in size and have larger nutrient-acquiring, photosynthetic and storage capacity, so they are able to invest in defence via specialized organs, such as EFNs. Hence, the more vulnerable juvenile stage should rely on other defensive strategies to reduce the

  20. Anatomical Modularity of Verbal Working Memory? Functional Anatomical Evidence from a Famous Patient with Short-Term Memory Deficits.

    PubMed

    Paulesu, Eraldo; Shallice, Tim; Danelli, Laura; Sberna, Maurizio; Frackowiak, Richard S J; Frith, Chris D

    2017-01-01

    Cognitive skills are the emergent property of distributed neural networks. The distributed nature of these networks does not necessarily imply a lack of specialization of the individual brain structures involved. However, it remains questionable whether discrete aspects of high-level behavior might be the result of localized brain activity of individual nodes within such networks. The phonological loop of working memory, with its simplicity, seems ideally suited for testing this possibility. Central to the development of the phonological loop model has been the description of patients with focal lesions and specific deficits. As much as the detailed description of their behavior has served to refine the phonological loop model, a classical anatomoclinical correlation approach with such cases falls short in telling whether the observed behavior is based on the functions of a neural system resembling that seen in normal subjects challenged with phonological loop tasks or whether different systems have taken over. This is a crucial issue for the cross correlation of normal cognition, normal physiology, and cognitive neuropsychology. Here we describe the functional anatomical patterns of JB, a historical patient originally described by Warrington et al. (1971), a patient with a left temporo-parietal lesion and selective short phonological store deficit. JB was studied with the H 2 15 O PET activation technique during a rhyming task, which primarily depends on the rehearsal system of the phonological loop. No residual function was observed in the left temporo-parietal junction, a region previously associated with the phonological buffer of working memory. However, Broca's area, the major counterpart of the rehearsal system, was the major site of activation during the rhyming task. Specific and autonomous activation of Broca's area in the absence of afferent inputs from the other major anatomical component of the phonological loop shows that a certain degree of

  1. Comparison of radiographic and anatomic femoral varus angle measurements in normal dogs.

    PubMed

    Swiderski, Jennifer K; Radecki, Steven V; Park, Richard D; Palmer, Ross H

    2008-01-01

    To determine if the clinically practiced method of radiographic femoral varus angle (R-FVA) measurement is repeatable, reproducible, and accurate. Radiographic and anatomic study. ANIMALS/SAMPLE POPULATION: Normal Walker hound cadavers (n=5) and femora (n=10). Cadavers were held in dorsally-recumbent and torso-elevated positions as 3 craniocaudal radiographs were made of each femur, by each of 2 different technicians. Femora were then harvested for direct measurement of anatomic femoral varus angle (A-FVA). R-FVA was measured on each radiograph by each of 3 examiners on 3 separate occasions. Intra-observer (repeatability) and inter-observer (reproducibility) variance in R-FVA measurement and the strength of relationship between R-FVA and A-FVA (accuracy) were determined. Mean (+/-SD) A-FVA was 5.2+/-2.1 degrees (range, 2.4-8.2 degrees). Mean (+/-SD) R-FVA was 5.8+/-1.0 degrees (range, 2.7-9.6 degrees). Intra-observer variance (range: 11-16%) and inter-observer variance (16%) were acceptable. The strength of relationship between measured R-FVA and A-FVA (maximum adjusted R(2)<0) was unacceptably low regardless of observer, patient position, or radiographic technician. R-FVA measurement was repeatable and reproducible, but not statistically accurate in predicting A-FVA in these 5 normal Walker hounds. The detected inaccuracy may be real or the result of a selection bias for normal dogs obscuring the true relationship. R-FVA may not be an accurate method of femoral varus measurement in dogs with A-FVA<10 degrees. Using Slocum's criteria for distal femoral osteotomy (R-FVA>10 degrees), the procedure would not have been erroneously performed in any of the normal dogs of this study.

  2. [Design of cross-sectional anatomical model focused on drainage pathways of paranasal sinuses].

    PubMed

    Zha, Y; Lv, W; Gao, Y L; Zhu, Z Z; Gao, Z Q

    2018-05-01

    Objective: To design and produce cross-sectional anatomical models of paranasal sinuses for the purpose of demonstrating drainage pathways of each nasal sinus for the young doctors. Method: We reconstructed the three-dimensional model of sinuses area based on CT scan data, and divided it into 5 thick cross-sectional anatomy models by 4 coronal plane,which cross middle points of agger nasi cell, ethmoid bulla, posterior ethmoid sinuses and sphenoid sinus respectively. Then a 3D printerwas used to make anatomical cross-sectional anatomical models. Result: Successfully produced a digital 3D printing cross-sectional models of paranasal sinuses. Sinus drainage pathways were observed on the models. Conclusion: The cross-sectional anatomical models made by us can exactly and intuitively demonstrate the ostia of each sinus cell and they can help the young doctors to understand and master the key anatomies and relationships which are important to the endoscopic sinus surgery. Copyright© by the Editorial Department of Journal of Clinical Otorhinolaryngology Head and Neck Surgery.

  3. Korean Type Distal Radius Anatomical Volar Plate System: A Preliminary Report

    PubMed Central

    Kim, Jeong Hwan; Kim, Jihyeung; Kim, Min Bom; Rhee, Seung Hwan; Gong, Hyun Sik; Lee, Young Ho

    2014-01-01

    Background Distal radius fracture is the most common fracture of the upper extremity, and approximately 60,000 distal radius fractures occur annually in Korea. Internal fixation with an anatomical volar locking plate is widely used in the treatment of unstable distal radius fractures. However, most of the currently used distal radius anatomical plate systems were designed based on the anatomical characteristics of Western populations. Recently, the Korean-type distal radius anatomical volar plate (K-DRAVP) system was designed and developed based on the anatomical characteristics of the distal radius of Koreans. The purpose of this study was to evaluate the preliminary results of the new K-DRAVP system, and to compare its radiologic and functional results with those of the other systems. Methods From March 2012 to October 2012, 46 patients with acute distal radius fractures who were treated with the K-DRAVP system at three hospitals were enrolled in this study. Standard posteroanterior and lateral radiographs were obtained to assess fracture healing, and three radiographic parameters (volar tilt, radial inclination, and radial length) were assessed to evaluate radiographic outcomes. The range of motion and grip strength, the Gartland and Werley scoring system, and the disabilities of the arm, shoulder and hand (DASH) questionnaire were used to assess clinical and functional outcomes. Results All radiologic parameters were restored to normal values, and maintained without any loosening or collapse until the time of final follow-up. Grip strength was restored to 84% of the value for the unaffected side. The mean range of motion of the wrist at final follow-up was restored to 77%-95% of the value for the unaffected side. According to the Gartland and Werley scoring system, there were 16 excellent, 26 good, and 4 fair results. The mean DASH score was 8.4 points. There were no complications after surgery. Conclusions The newly developed K-DRAVP system could be used to

  4. Anatomical risk evaluation of iatrogenic injury to the infrapatellar branch of the saphenous nerve during medial meniscus arthroscopic surgery.

    PubMed

    Koch, Guillaume; Kling, Agathe; Ramamurthy, Nitin; Edalat, Faramarz; Cazzato, Roberto Luigi; Kahn, Jean-Luc; Garnon, Julien; Clavert, Philippe

    2017-06-01

    To determine the relationship of the medial meniscus with the infrapatellar branches of the saphenous nerve, the primary goal is to define and characterize different risk areas for these nerves during medial meniscus surgery. After dissecting 20 embalmed cadaver knees, we defined 7 readily identifiable anatomical landmarks. For each knee, we recorded 2 morphological criteria and 16 measurements. The most common anatomical course is a main trunk that is 8 mm anterior to the tuberculum adductorium and 60 mm posterior to the midpoint of the medial patellar margin. It has two main infrapatellar branches. The nerve division is 23 mm above the joint line. The path is oblique with an angle of 55.5°. The anterior meniscal landmark is 24 mm from the upper branch and 42.5 mm from the lower branch. The posterior meniscal landmark is 55 mm from the upper branch and 38 mm from the lower branch. We defined a common anatomical course for the saphenous nerve and its infrapatellar branches. Then, three different areas were defined at risk for iatrogenic nerve injuries during medial meniscus.

  5. Predictive factors of open globe injury in patients requiring vitrectomy.

    PubMed

    Pimolrat, Weeraya; Choovuthayakorn, Janejit; Watanachai, Nawat; Patikulsila, Direk; Kunavisarut, Paradee; Chaikitmongkol, Voraporn; Ittipunkul, Nimitr

    2014-01-01

    To determine the outcomes and predictive factors of patients with open globe injury requiring pars plana vitrectomy (PPV). The medical records of 114 patients age 10 years or older who had undergone PPV due to ocular trauma, with at least 6 months follow up, were retrospectively reviewed. The mean age of the patients was 42 (SD14) years, with males accounting for 89% of the cases. Penetrating eye injury was the most common injury mechanism (43%) with most injuries occurring secondary to work related incidents (54%). After surgical interventions, 78% of the patients had visual improvement of one or more Snellen lines, while no light perception occurred in 10%. Anatomical attachment was achieved in 87% of eyes at the final follow up. Logistic regression analysis showed that the presence of a relative afferent pupillary defect (RAPD) was a significant predictive factor of visual outcome, while initial retinal detachment was a significant predictor of anatomical outcome. Pupillary reaction is an important presenting ocular sign in estimating the post-vitrectomy poor visual outcome for open globe injury. Vision was restored and improved in more than half of the patients in this study; however, long-term sequelae should be monitored. Copyright © 2013 Elsevier Ltd. All rights reserved.

  6. Impact of correction factors in human brain lesion-behavior inference.

    PubMed

    Sperber, Christoph; Karnath, Hans-Otto

    2017-03-01

    Statistical voxel-based lesion-behavior mapping (VLBM) in neurological patients with brain lesions is frequently used to examine the relationship between structure and function of the healthy human brain. Only recently, two simulation studies noted reduced anatomical validity of this method, observing the results of VLBM to be systematically misplaced by about 16 mm. However, both simulation studies differed from VLBM analyses of real data in that they lacked the proper use of two correction factors: lesion size and "sufficient lesion affection." In simulation experiments on a sample of 274 real stroke patients, we found that the use of these two correction factors reduced misplacement markedly compared to uncorrected VLBM. Apparently, the misplacement is due to physiological effects of brain lesion anatomy. Voxel-wise topographies of collateral damage in the real data were generated and used to compute a metric for the inter-voxel relation of brain damage. "Anatomical bias" vectors that were solely calculated from these inter-voxel relations in the patients' real anatomical data, successfully predicted the VLBM misplacement. The latter has the potential to help in the development of new VLBM methods that provide even higher anatomical validity than currently available by the proper use of correction factors. Hum Brain Mapp 38:1692-1701, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  7. My Corporis Fabrica: an ontology-based tool for reasoning and querying on complex anatomical models

    PubMed Central

    2014-01-01

    Background Multiple models of anatomy have been developed independently and for different purposes. In particular, 3D graphical models are specially useful for visualizing the different organs composing the human body, while ontologies such as FMA (Foundational Model of Anatomy) are symbolic models that provide a unified formal description of anatomy. Despite its comprehensive content concerning the anatomical structures, the lack of formal descriptions of anatomical functions in FMA limits its usage in many applications. In addition, the absence of connection between 3D models and anatomical ontologies makes it difficult and time-consuming to set up and access to the anatomical content of complex 3D objects. Results First, we provide a new ontology of anatomy called My Corporis Fabrica (MyCF), which conforms to FMA but extends it by making explicit how anatomical structures are composed, how they contribute to functions, and also how they can be related to 3D complex objects. Second, we have equipped MyCF with automatic reasoning capabilities that enable model checking and complex queries answering. We illustrate the added-value of such a declarative approach for interactive simulation and visualization as well as for teaching applications. Conclusions The novel vision of ontologies that we have developed in this paper enables a declarative assembly of different models to obtain composed models guaranteed to be anatomically valid while capturing the complexity of human anatomy. The main interest of this approach is its declarativity that makes possible for domain experts to enrich the knowledge base at any moment through simple editors without having to change the algorithmic machinery. This provides MyCF software environment a flexibility to process and add semantics on purpose for various applications that incorporate not only symbolic information but also 3D geometric models representing anatomical entities as well as other symbolic information like the

  8. Etiologic analysis of 100 anatomically failed dacryocystorhinostomies

    PubMed Central

    Dave, Tarjani Vivek; Mohammed, Faraz Ali; Ali, Mohammad Javed; Naik, Milind N

    2016-01-01

    Background The aim of this study was to assess the etiological factors contributing to the failure of a dacryocystorhinostomy (DCR). Patients and methods Retrospective review was performed in 100 consecutive patients who were diagnosed with anatomically failed DCR at presentation to a tertiary care hospital over a 5-year period from 2010 to 2015. Patient records were reviewed for demographic data, type of past surgery, preoperative endoscopic findings, previous use of adjuvants such as intubation and mitomycin C, and intraoperative notes during the re-revision. The potential etiological factors for failure were noted. Results Of the 100 patients with failed DCRs, the primary surgery was an external DCR in 73 and endoscopic DCR in 27 patients. Six patients in each group had multiple revisions. The mean ages at presentation in the external and endoscopic groups were 39.41 years and 37.19 years, respectively. All patients presented with epiphora. The most common causes of failure were inadequate osteotomy (69.8% in the external group and 85.1% in the endoscopic group, P=0.19) followed by inadequate or inappropriate sac marsupialization (60.2% in the external group and 77.7% in the endoscopic group, P=0.16) and cicatricial closure of the ostium (50.6% in the external group and 55.5% in the endoscopic group, P=0.83). The least common causes such as ostium granulomas and paradoxical middle turbinate (1.37%, n=1) were noted in the external group only. Conclusion Inadequate osteotomy, incomplete sac marsupialization, and cicatricial closure of the ostium were the most common causes of failure and did not significantly differ in the external and endoscopic groups. Meticulous evaluation to identify causative factors for failure and addressing them are crucial for subsequent successful outcomes. PMID:27555748

  9. Anatomical Study of the Clavicles in a Chinese Population

    PubMed Central

    Qiu, Xu-sheng; Wang, Xiao-bo; Zhang, Yan; Zhu, Yan-Cheng; Guo, Xia; Chen, Yi-xin

    2016-01-01

    Background. A reemergence of interest in clavicle anatomy was prompted because of the advocacy for operative treatment of midshaft clavicle fractures. Several anatomical studies of the clavicle have been performed in western population. However, there was no anatomical study of clavicle in Chinese population. Patients and Methods. 52 patients were included in the present study. Three-dimensional reconstructions of the clavicles were generated. The length of the clavicle, the widths and thicknesses of the clavicle, curvatures of the clavicle, the areas of the intramedullary canal, and sectional areas of the clavicle were measured. All the measurements were compared between genders and two sides. Results. The mean length of the clavicles was 144.2 ± 12.0 mm. Clavicles in males were longer, wider, and thicker than in females; also males have different curvatures in both planes compared with females. The men's intramedullary canals and sectional areas of the clavicle were larger than those of women. No significant difference between the sides was found for all the measurements. Conclusion. This study provided an anatomical data of the clavicle in a Chinese population. These clavicle dimensions can be applied to the modifications of the contemporary clavicle plate or a new development for the Chinese population. PMID:27088088

  10. Effects of anatomical position on esophageal transit time: A biomagnetic diagnostic technique

    PubMed Central

    Cordova-Fraga, Teodoro; Sosa, Modesto; Wiechers, Carlos; la Roca-Chiapas, Jose Maria De; Moreles, Alejandro Maldonado; Bernal-Alvarado, Jesus; Huerta-Franco, Raquel

    2008-01-01

    AIM: To study the esophageal transit time (ETT) and compare its mean value among three anatomical inclinations of the body; and to analyze the correlation of ETT to body mass index (BMI). METHODS: A biomagnetic technique was implemented to perform this study: (1) The transit time of a magnetic marker (MM) through the esophagus was measured using two fluxgate sensors placed over the chest of 14 healthy subjects; (2) the ETT was assessed in three anatomical positions (at upright, fowler, and supine positions; 90º, 45º and 0º, respectively). RESULTS: ANOVA and Tuckey post-hoc tests demonstrated significant differences between ETT mean of the different positions. The ETT means were 5.2 ± 1.1 s, 6.1 ± 1.5 s, and 23.6 ± 9.2 s for 90º, 45º and 0º, respectively. Pearson correlation results were r = -0.716 and P < 0.001 by subjects’ anatomical position, and r = -0.024 and P > 0.05 according the subject’s BMI. CONCLUSION: We demonstrated that using this biomagnetic technique, it is possible to measure the ETT and the effects of the anatomical position on the ETT. PMID:18837088

  11. Bayesian CP Factorization of Incomplete Tensors with Automatic Rank Determination.

    PubMed

    Zhao, Qibin; Zhang, Liqing; Cichocki, Andrzej

    2015-09-01

    CANDECOMP/PARAFAC (CP) tensor factorization of incomplete data is a powerful technique for tensor completion through explicitly capturing the multilinear latent factors. The existing CP algorithms require the tensor rank to be manually specified, however, the determination of tensor rank remains a challenging problem especially for CP rank . In addition, existing approaches do not take into account uncertainty information of latent factors, as well as missing entries. To address these issues, we formulate CP factorization using a hierarchical probabilistic model and employ a fully Bayesian treatment by incorporating a sparsity-inducing prior over multiple latent factors and the appropriate hyperpriors over all hyperparameters, resulting in automatic rank determination. To learn the model, we develop an efficient deterministic Bayesian inference algorithm, which scales linearly with data size. Our method is characterized as a tuning parameter-free approach, which can effectively infer underlying multilinear factors with a low-rank constraint, while also providing predictive distributions over missing entries. Extensive simulations on synthetic data illustrate the intrinsic capability of our method to recover the ground-truth of CP rank and prevent the overfitting problem, even when a large amount of entries are missing. Moreover, the results from real-world applications, including image inpainting and facial image synthesis, demonstrate that our method outperforms state-of-the-art approaches for both tensor factorization and tensor completion in terms of predictive performance.

  12. Determination of effective loss factors in reduced SEA models

    NASA Astrophysics Data System (ADS)

    Chimeno Manguán, M.; Fernández de las Heras, M. J.; Roibás Millán, E.; Simón Hidalgo, F.

    2017-01-01

    The definition of Statistical Energy Analysis (SEA) models for large complex structures is highly conditioned by the classification of the structure elements into a set of coupled subsystems and the subsequent determination of the loss factors representing both the internal damping and the coupling between subsystems. The accurate definition of the complete system can lead to excessively large models as the size and complexity increases. This fact can also rise practical issues for the experimental determination of the loss factors. This work presents a formulation of reduced SEA models for incomplete systems defined by a set of effective loss factors. This reduced SEA model provides a feasible number of subsystems for the application of the Power Injection Method (PIM). For structures of high complexity, their components accessibility can be restricted, for instance internal equipments or panels. For these cases the use of PIM to carry out an experimental SEA analysis is not possible. New methods are presented for this case in combination with the reduced SEA models. These methods allow defining some of the model loss factors that could not be obtained through PIM. The methods are validated with a numerical analysis case and they are also applied to an actual spacecraft structure with accessibility restrictions: a solar wing in folded configuration.

  13. Anatomical and physical changes in leaves during the production of tamales.

    PubMed

    Angeles, Guillermo; Lascurain, Maite; Davalos-Sotelo, Raymundo; Zarate-Morales, Reyna Paula; Ortega-Escalona, Fernando

    2013-08-01

    Tamale preparation has a long tradition in Mexico. To understand which material properties have been considered important for this purpose throughout the years, a study was conducted of the anatomical, chemical, and mechanical properties of the leaves of four plant species used in tamale preparation in Veracruz, Mexico: Calathea misantlensis, Canna indica, Musa paradisiaca, and Oreopanax capitatus. Four cooking treatments were considered: fresh (F), roasted (soasado, R), steamed (S), and roasted plus steamed (R/S). Chemical, anatomical, and mechanical analyses were conducted before and after each treatment. Leaf samples were tested for tensile strength at both parallel and perpendicular orientation relative to the fibers. Musa paradisiaca had the highest proportion of cellulose, while the remaining species shared similar lower proportions. Leaves were stronger and stiffer in the longitudinal direction of the fibers. Musa paradisiaca leaves had higher values of mechanical strength than the other species. The cooking process that most affected the mechanical properties was steaming. The chemical constituents of the leaves are closely correlated with their physical properties. The treatment that caused the greatest decrease in leaf physical integrity was steaming, while the combination of roasting and steaming showed similar results to those of steaming alone. No evident anatomical changes are produced by any of the treatments. This is one of the few studies comparing physical, chemical, and anatomical characteristics of leaves used for human consumption, before and after cooking.

  14. Mathematical modelling of the growth of human fetus anatomical structures.

    PubMed

    Dudek, Krzysztof; Kędzia, Wojciech; Kędzia, Emilia; Kędzia, Alicja; Derkowski, Wojciech

    2017-09-01

    The goal of this study was to present a procedure that would enable mathematical analysis of the increase of linear sizes of human anatomical structures, estimate mathematical model parameters and evaluate their adequacy. Section material consisted of 67 foetuses-rectus abdominis muscle and 75 foetuses- biceps femoris muscle. The following methods were incorporated to the study: preparation and anthropologic methods, image digital acquisition, Image J computer system measurements and statistical analysis method. We used an anthropologic method based on age determination with the use of crown-rump length-CRL (V-TUB) by Scammon and Calkins. The choice of mathematical function should be based on a real course of the curve presenting growth of anatomical structure linear size Ύ in subsequent weeks t of pregnancy. Size changes can be described with a segmental-linear model or one-function model with accuracy adequate enough for clinical purposes. The interdependence of size-age is described with many functions. However, the following functions are most often considered: linear, polynomial, spline, logarithmic, power, exponential, power-exponential, log-logistic I and II, Gompertz's I and II and von Bertalanffy's function. With the use of the procedures described above, mathematical models parameters were assessed for V-PL (the total length of body) and CRL body length increases, rectus abdominis total length h, its segments hI, hII, hIII, hIV, as well as biceps femoris length and width of long head (LHL and LHW) and of short head (SHL and SHW). The best adjustments to measurement results were observed in the exponential and Gompertz's models.

  15. [3D modeling of the female pelvis by Computer-Assisted Anatomical Dissection: Applications and perspectives].

    PubMed

    Balaya, V; Uhl, J-F; Lanore, A; Salachas, C; Samoyeau, T; Ngo, C; Bensaid, C; Cornou, C; Rossi, L; Douard, R; Bats, A-S; Lecuru, F; Delmas, V

    2016-05-01

    To achieve a 3D vectorial model of a female pelvis by Computer-Assisted Anatomical Dissection and to assess educationnal and surgical applications. From the database of "visible female" of Visible Human Project(®) (VHP) of the "national library of medicine" NLM (United States), we used 739 transverse anatomical slices of 0.33mm thickness going from L4 to the trochanters. The manual segmentation of each anatomical structures was done with Winsurf(®) software version 4.3. Each anatomical element was built as a separate vectorial object. The whole colored-rendered vectorial model with realistic textures was exported in 3Dpdf format to allow a real time interactive manipulation with Acrobat(®) pro version 11 software. Each element can be handled separately at any transparency, which allows an anatomical learning by systems: skeleton, pelvic organs, urogenital system, arterial and venous vascularization. This 3D anatomical model can be used as data bank to teach of the fundamental anatomy. This 3D vectorial model, realistic and interactive constitutes an efficient educational tool for the teaching of the anatomy of the pelvis. 3D printing of the pelvis is possible with the new printers. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  16. Patients’ satisfaction with anatomic polyurethane implants

    PubMed Central

    2017-01-01

    This paper presents patients satisfaction using anatomical polyurethane breast implants. We performed surgery on 525 patients, 370 of which were primary and 155 were secondary to various causes such as capsular contracture, ruptured implants, volume changes, and incorrect positioning of the implant. The advantages of silicone polyurethane covers shown high level of patient satisfaction, low incidence of capsular contracture, and absence of implant rotation, and late seroma. PMID:28497022

  17. Levator hiatal area as a risk factor for cystocele recurrence after surgery: a prospective study.

    PubMed

    Vergeldt, T F M; Notten, K J B; Weemhoff, M; van Kuijk, S M J; Mulder, F E M; Beets-Tan, R G; Vliegen, R F A; Gondrie, E T C M; Bergmans, M G M; Roovers, J P W R; Kluivers, K B

    2015-07-01

    To investigate whether increased levator hiatal area, measured preoperatively, was independently associated with anatom-ical cystocele recurrence 12 months after anterior colporrhaphy. Multicentre prospective cohort study. Nine teaching hospitals in the Netherlands. Women planned for conventional anterior colporrhaphy without mesh. Women underwent physical examination, translabial three-dimensional (3D) ultrasound and magnetic resonance imaging (MRI) prior to surgery. At 12 months after surgery the physical examination was repeated. Women with and without anatomical cystocele recurrence were compared to assess the association with levator hiatal area on 3D ultrasound, levator hiatal area on MRI, and potential confounding factors. The receiver operating characteristic (ROC) curve was created to quantify the discriminative ability of using levator hiatal area to predict anatomical cystocele recurrence. Of 139 included women, 76 (54.7%) had anatomical cystocele recurrence. Preoperative stage 3 or 4 and increased levator hiatal area during Valsalva on ultrasound were significantly associated with cystocele recurrence, with odds ratios of 3.47 (95% confidence interval, 95% CI 1.66-7.28) and 1.06 (95% CI 1.01-1.11) respectively. The area under the ROC curve was 0.60 (95% CI 0.51-0.70) for levator hiatal area during Valsalva on ultrasound, and 0.65 (95% CI 0.55-0.71) for preoperative Pelvic Organ Prolapse Quantification (POP-Q) stage. Increased levator hiatal area during Valsalva on ultrasound prior to surgery and preoperative stage 3 or 4 are independent risk factors for anatomical cystocele recurrence after anterior colporrhaphy; however, increased levator hiatal area as the sole factor for predicting anatomical cystocele recurrence after surgery shows poor test characteristics. © 2015 Royal College of Obstetricians and Gynaecologists.

  18. Anatomic variations in vascular and collecting systems of kidneys from deceased donors.

    PubMed

    Costa, H C; Moreira, R J; Fukunaga, P; Fernandes, R C; Boni, R C; Matos, A C

    2011-01-01

    Nephroureterectomy for transplantation has increased owing to the greater number of deceased donors. Anatomic variations may complicate the procedure or, if unrecognized, compromise the viability of kidneys for transplantation. We reviewed 254 surgical descriptions of nephroureterectomy specimens from January 2008 to December 2009. All organs collected according by standard techniques were evaluated for age, cause of death, renal function, frequency of injury during the procedure, as well as variations in the vascular and collecting systems. The mean donor age was 42 years (range, 2-74). The mean serum creatinine was 1.2 mg/dL (range, 1.0-7.0). The causes of death were cerebrovascular cause (stroke; n = 130), traumatic brain injury (n = 81) or other cause (n = 43). Among the anatomic variations: 8.6% (n = 22) were right arterial anatomical variations: 19 cases with 2 arteries and 3 cases with 3 arteries. In 25 cases (9.8%) the identified variation was the left artery: 2 arteries (n = 23), 3 arteries (n = 1) and 4 arteries (n = 1). We observed 9.8% on right side and 1.5% on left side venous anatomic variations, including 24 cases with 2 veins on the right side and 4 cases with 2 veins on the left side. Three cases of a retroaortic left renal vein and 1 case of a retro necklace vein (anterior and posterior to the aorta). Two cases of ureteral duplication were noted on the left and 1 on the right kidney. There were 3 horseshoe and 1 pelvic kidney. In 7.5% of cases, an injury to the graft included ureteral (n = 3), arterial (n = 10), or venous (n = 6). The most common anatomic variation was arterial (17.8%). Duplication of the renal vein was more frequent on the right. The high incidences of anatomic variations require more attention in the dissection of the renal hilum to avoid an injury that may compromise the graft. Copyright © 2011 Elsevier Inc. All rights reserved.

  19. Proximity of arthroscopic ankle stabilization procedures to surrounding structures: an anatomic study.

    PubMed

    Drakos, Mark; Behrens, Steve B; Mulcahey, Mary K; Paller, David; Hoffman, Eve; DiGiovanni, Christopher W

    2013-06-01

    To examine the anatomy of the lateral ankle after arthroscopic repair of the lateral ligament complex (anterior talofibular ligament [ATFL] and calcaneofibular ligament [CFL]) with regard to structures at risk. Ten lower extremity cadaveric specimens were obtained and were screened for gross anatomic defects and pre-existing ankle laxity. The ATFL and CFL were sectioned from the fibula by an open technique. Standard anterolateral and anteromedial arthroscopy portals were made. An additional portal was created 2 cm distal to the anterolateral portal. The articular surface of the fibula was identified, and the ATFL and CFL were freed from the superficial and deeper tissues. Suture anchors were placed in the fibula at the ATFL and CFL origins and were used to repair the origin of the lateral collateral structures. The distance from the suture knot to several local anatomic structures was measured. Measurements were taken by 2 separate observers, and the results were averaged. Several anatomic structures lie in close proximity to the ATFL and CFL sutures. The ATFL sutures entrapped 9 of 55 structures, and no anatomic structures were inadvertently entrapped by the CFL sutures. The proximity of the peroneus tertius and the extensor tendons to the ATFL makes them at highest risk of entrapment, but the proximity of the intermediate branch of the superficial peroneal nerve (when present) is a risk with significant morbidity. Our results indicate that the peroneus tertius and extensor tendons have the highest risk for entrapment and show the smallest mean distances from the anchor knot to the identified structure. Careful attention to these structures, as well as the superficial peroneal nerve, is mandatory to prevent entrapment of tendons and nerves when one is attempting arthroscopic lateral ankle ligament reconstruction. Defining the anatomic location and proximity of the intervening structures adjacent to the lateral ligament complex of the ankle may help clarify the

  20. Investigating Science Student Teachers' Ideas about Function and Anatomical Form of Two Human Sensory Organs, the Eye and the Ear

    ERIC Educational Resources Information Center

    Kunt, Halil

    2016-01-01

    The purpose of this research was to determine science student teachers' level of knowledge about the anatomical structure of two sensory organs, the eye and the ear, in addition to vision and hearing processes. Conducted with 86 science student teachers, research utilized drawing methods and open-ended questions as data collection instruments. The…

  1. Evaluation of influences of the Viennese Anatomical School on the work of the Croatian Anatomist Jelena Krmpotic-Nemanic.

    PubMed

    Dinjar, Kristijan; Toth, Jurica; Atalic, Bruno; Radanovic, Danijela; Maric, Svjetlana

    2012-01-01

    This paper tries to evaluate the connections between the Viennese Anatomical School and the Croatian Anatomist Jelena Krmpotic-Nemanic. 17 papers written by Professor Jelena Krmpotic-Nemanic in the last decade of her life were chosen for analyses. According to their themes they could be divided into three groups: ones which evaluate the anatomical terminology, ones which research the development of anatomical structures, and ones which describe the anatomical variations. Mentioned papers were analysed through their topics, methods of research and cited references. Analyses of the mentioned papers revealed the indirect link between the Viennese Anatomical School and the Professor Jelena Krmpotic-Nemanic, through her mentor Professor Drago Perovic, regarding the themes and the methods of her anatomical researches. It has also showed her preference for Austrian and German anatomical textbooks and atlases, primarily ones published in Vienna and Jena, rather than English and American ones. Finally, her direct connections with the Viennese Institute for the History of Medicine and the Viennese Josephinum Wax Models Museum were emphasized. Mentioned indirect and direct influences of the Viennese Anatomical School on the work of Professor Jelena Krmpotic-Nemanic were critically appraised.

  2. The morphometry of the laryngeal phonatory system - base of the anatomical study of the voice aptitudes.

    PubMed

    Hînganu, Marius Valeriu; Cozma, Romică Sebastian; Ciochină, Paula; Scutariu, Irina Andreea; Asimionoaiei-Simionescu, Cristina; Hînganu, Delia

    2017-01-01

    Speaking is one of the characteristics of the human race and the main factor that has marked our progress over time. The singing voice is the crowning of the speech act and the main component of the lyrical manifestation of personality. Doctors in various fields, but especially anatomists have been concerned about discovering how the voice and the substrate of its variability are formed, but these aspects have not yet been fully deciphered. This study is the starting point in our research on the phonation system, organized on three levels: laryngeal, oral, palatinal, pharyngeal, epiglottal and nasal. We performed the dissection of seven embalmed anatomical parts, on which, we made measurements of the anatomical elements involved in the phonation. We performed the same measurements on a batch of seven adults investigated by magnetic resonance imaging (MRI). The results were entered into the statistical calculation formulas and compared with each other and with the literature. The results of the study show that certain values resulting from the calculation formulas remain constant and others vary greatly from each individuals and gender.

  3. Determining Factors of Environmental Education in Spanish Universities

    ERIC Educational Resources Information Center

    Larrán, Manuel; Andrades, Javier

    2015-01-01

    Purpose: This study aims to analyze the main factors that might determine the extent to which Spanish organizational management educators use environmental stand-alone subjects to equip students with alternative views of business. To give a more qualitative study, this paper also provides a more detailed curriculum analysis from a double point of…

  4. Anatomic variation of depth-dependent mechanical properties in neonatal bovine articular cartilage.

    PubMed

    Silverberg, Jesse L; Dillavou, Sam; Bonassar, Lawrence; Cohen, Itai

    2013-05-01

    Articular cartilage has well known depth-dependent structure and has recently been shown to have similarly non-uniform depth-dependent mechanical properties. Here, we study anatomic variation of the depth-dependent shear modulus and energy dissipation rate in neonatal bovine knees. The regions we specifically focus on are the patellofemoral groove, trochlea, femoral condyle, and tibial plateau. In every sample, we find a highly compliant region within the first 500 µm of tissue measured from the articular surface, where the local shear modulus is reduced by up to two orders of magnitude. Comparing measurements taken from different anatomic sites, we find statistically significant differences localized within the first 50 µm. Histological images reveal these anatomic variations are associated with differences in collagen density and fiber organization. Copyright © 2012 Orthopaedic Research Society.

  5. Dendrogeochronologic and Anatomic Analysis of Excavated Plains Cottonwoods Determine Overbank Sedimentation Rates and Historical Channel Positions Along the Interior of a Migrating Meander Bend, Powder River, Montana

    NASA Astrophysics Data System (ADS)

    Metzger, T. L.; Pizzuto, J. E.; Schook, D. M.; Hasse, T. R.; Affinito, R. A.

    2017-12-01

    Dendrochronological dating of buried trees precisely determines the germination year and identifies the stratigraphic context of germination for the trees. This recently developed application of dendrochronology provides accurate time-averaged sedimentation rates of overbank deposition along floodplains and can be used to identify burial events. Previous studies have demonstrated that tamarisk (Tamarix ramosissima) and sandbar willow (Salix exigua) develop anatomical changes within the tree rings (increased vessel size and decreased ring widths) on burial, but observations of plains cottonwood (Populus deltoides ssp. monilifera) are lacking. In September 2016 and June 2017, five buried plains cottonwoods were excavated along a single transect of the interior of a meander bend of the Powder River, Montana. Sediment samples were obtained near each tree for 210Pb and 137Cs dating, which will allow for comparison between dendrochronological and isotopic dating methods. The plains cottonwood samples collected exhibit anatomical changes associated with burial events that are observed in other species. All trees germinated at the boundary between thinly bedded fine sand and mud and coarse sand underlain by sand and gravel, indicating plains cottonwoods germinate on top of point bars prior to overbank deposition. The precise germination age and depth provide elevations and minimum age constraints for the point bar deposits and maximum ages for the overlying sediment, helping constrain past channel positions and overbank deposition rates. Germination years of the excavated trees, estimated from cores taken 1.5 m above ground level, range from 2014 to 1862. Accurate establishment years determined by cross-dating the buried section of the tree can add an additional 10 years to the cored age. The sedimentation rate and accumulation thickness varied with tree age. The germination year, total sediment accumulation, and average sedimentation rate at the five sampled trees is

  6. Comparison of femur tunnel aperture location in patients undergoing transtibial and anatomical single-bundle anterior cruciate ligament reconstruction.

    PubMed

    Lee, Dae-Hee; Kim, Hyun-Jung; Ahn, Hyeong-Sik; Bin, Seong-Il

    2016-12-01

    Although three-dimensional computed tomography (3D-CT) has been used to compare femoral tunnel position following transtibial and anatomical anterior cruciate ligament (ACL) reconstruction, no consensus has been reached on which technique results in a more anatomical position because methods of quantifying femoral tunnel position on 3D-CT have not been consistent. This meta-analysis was therefore performed to compare femoral tunnel location following transtibial and anatomical ACL reconstruction, in both the low-to-high and deep-to-shallow directions. This meta-analysis included all studies that used 3D-CT to compare femoral tunnel location, using quadrant or anatomical coordinate axis methods, following transtibial and anatomical (AM portal or OI) single-bundle ACL reconstruction. Six studies were included in the meta-analysis. Femoral tunnel location was 18 % higher in the low-to-high direction, but was not significant in the deep-to-shallow direction, using the transtibial technique than the anatomical methods, when measured using the anatomical coordinate axis method. When measured using the quadrant method, however, femoral tunnel positions were significantly higher (21 %) and shallower (6 %) with transtibial than anatomical methods of ACL reconstruction. The anatomical ACL reconstruction techniques led to a lower femoral tunnel aperture location than the transtibial technique, suggesting the superiority of anatomical techniques for creating new femoral tunnels during revision ACL reconstruction in femoral tunnel aperture location in the low-to-high direction. However, the mean difference in the deep-to-shallow direction differed by method of measurement. Meta-analysis, Level II.

  7. Familial intracranial aneurysms: is anatomic vulnerability heritable?

    PubMed

    Mackey, Jason; Brown, Robert D; Moomaw, Charles J; Hornung, Richard; Sauerbeck, Laura; Woo, Daniel; Foroud, Tatiana; Gandhi, Dheeraj; Kleindorfer, Dawn; Flaherty, Matthew L; Meissner, Irene; Anderson, Craig; Rouleau, Guy; Connolly, E Sander; Deka, Ranjan; Koller, Daniel L; Abruzzo, Todd; Huston, John; Broderick, Joseph P

    2013-01-01

    Previous studies have suggested that family members with intracranial aneurysms (IAs) often harbor IAs in similar anatomic locations. IA location is important because of its association with rupture. We tested the hypothesis that anatomic susceptibility to IA location exists using a family-based IA study. We identified all affected probands and first-degree relatives (FDRs) with a definite or probable phenotype in each family. We stratified each IA of the probands by major arterial territory and calculated each family's proband-FDR territory concordance and overall contribution to the concordance analysis. We then matched each family unit to an unrelated family unit selected randomly with replacement and performed 1001 simulations. The median concordance proportions, odds ratios (ORs), and P values from the 1001 logistic regression analyses were used to represent the final results of the analysis. There were 323 family units available for analysis, including 323 probands and 448 FDRs, with a total of 1176 IAs. IA territorial concordance was higher in the internal carotid artery (55.4% versus 45.6%; OR, 1.54 [1.04-2.27]; P=0.032), middle cerebral artery (45.8% versus 30.5%; OR, 1.99 [1.22-3.22]; P=0.006), and vertebrobasilar system (26.6% versus 11.3%; OR, 2.90 [1.05-8.24], P=0.04) distributions in the true family compared with the comparison family. Concordance was also higher when any location was considered (53.0% versus 40.7%; OR, 1.82 [1.34-2.46]; P<0.001). In a highly enriched sample with familial predisposition to IA development, we found that IA territorial concordance was higher when probands were compared with their own affected FDRs than with comparison FDRs, which suggests that anatomic vulnerability to IA formation exists. Future studies of IA genetics should consider stratifying cases by IA location.

  8. Utilization management in anatomic pathology.

    PubMed

    Lewandrowski, Kent; Black-Schaffer, Steven

    2014-01-01

    There is relatively little published literature concerning utilization management in anatomic pathology. Nonetheless there are many utilization management opportunities that currently exist and are well recognized. Some of these impact only the cost structure within the pathology department itself whereas others reduce charges for third party payers. Utilization management may result in medical legal liabilities for breaching the standard of care. For this reason it will be important for pathology professional societies to develop national utilization guidelines to assist individual practices in implementing a medically sound approach to utilization management. © 2013.

  9. Giving Ourselves: The Ethics of Anatomical Donation

    ERIC Educational Resources Information Center

    Gunderman, Richard B.

    2008-01-01

    In some European countries, such as Italy, medical education is threatened by a dearth of anatomical specimens. Such a shortage could spread to other nations, including the United States. This article addresses two ethical questions in body donation. Why might people choose to donate their bodies to education and science? What sorts of ethical…

  10. Evolution of the Anatomical Theatre in Padova

    ERIC Educational Resources Information Center

    Macchi, Veronica; Porzionato, Andrea; Stecco, Carla; Caro, Raffaele

    2014-01-01

    The anatomical theatre played a pivotal role in the evolution of medical education, allowing students to directly observe and participate in the process of dissection. Due to the increase of training programs in clinical anatomy, the Institute of Human Anatomy at the University of Padova has renovated its dissecting room. The main guidelines in…

  11. A probabilistic framework to infer brain functional connectivity from anatomical connections.

    PubMed

    Deligianni, Fani; Varoquaux, Gael; Thirion, Bertrand; Robinson, Emma; Sharp, David J; Edwards, A David; Rueckert, Daniel

    2011-01-01

    We present a novel probabilistic framework to learn across several subjects a mapping from brain anatomical connectivity to functional connectivity, i.e. the covariance structure of brain activity. This prediction problem must be formulated as a structured-output learning task, as the predicted parameters are strongly correlated. We introduce a model selection framework based on cross-validation with a parametrization-independent loss function suitable to the manifold of covariance matrices. Our model is based on constraining the conditional independence structure of functional activity by the anatomical connectivity. Subsequently, we learn a linear predictor of a stationary multivariate autoregressive model. This natural parameterization of functional connectivity also enforces the positive-definiteness of the predicted covariance and thus matches the structure of the output space. Our results show that functional connectivity can be explained by anatomical connectivity on a rigorous statistical basis, and that a proper model of functional connectivity is essential to assess this link.

  12. Anatomic variations in intrahepatic bile ducts in a north Indian population.

    PubMed

    Sharma, Vijay; Saraswat, Vivek Anand; Baijal, Sanjay Saran; Choudhuri, Gourdas

    2008-07-01

    In the present study, we described the anatomical variations in the branching patterns of intrahepatic bile ducts (IHD) and determined the frequency of each variation in north Indian patients. There are no data from India. The study group consisted of 253 consecutive patients (131 women) undergoing endoscopic retrograde cholangiograms for different indications. Anatomical variations in IHD were classified according to the branching pattern of the right anterior segmental duct (RASD) and the right posterior segmental duct (RPSD), presence or absence of first-order branch of left hepatic duct (LHD) and of an accessory hepatic duct. Anatomy of the IHD was typical in 52.9% of cases (n = 134), showing triple confluence in 11.46% (n = 29), anomalous drainage of the RPSD into the LHD in 18.2% (n = 46), anomalous drainage of the RPSD into the common hepatic duct (CHD) in 7.1% (n = 18), drainage of the right hepatic duct (RHD) into the cystic duct 0.4% (n = 1), presence of an accessory duct leading to the CHD or RHD in 4.7% (n = 12), individual drainage of the LHD into the RHD or CHD in 2.4% (n = 6), and unclassified or complex variations in 2.7% (n = 7). None had anomalous drainage of RPSD into the cystic duct. The branching pattern of IHD was atypical in 47% patients. The two most common variations were drainage of the RPSD into the LHD (18.2%) and triple confluence of the RASD, RPSD, and LHD (11.5%).

  13. 16 CFR § 1119.4 - Factors considered in determining civil penalties.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... penalties. § 1119.4 Section § 1119.4 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION CONSUMER PRODUCT SAFETY ACT REGULATIONS CIVIL PENALTY FACTORS § 1119.4 Factors considered in determining civil penalties. (a) Statutory Factors. (1) Section 20(b) of the CPSA, section 5(c)(3) of the FHSA, and section 5...

  14. Image-guided brachytherapy for cervical cancer: analysis of D2 cc hot spot in three-dimensional and anatomic factors affecting D2 cc hot spot in organs at risk.

    PubMed

    Kim, Robert Y; Dragovic, Alek F; Whitley, Alexander C; Shen, Sui

    2014-01-01

    To analyze the D2 cc hot spot in three-dimensional CT and anatomic factors affecting the D2 cc hot spot in organs at risk (OARs). Thirty-one patients underwent pelvic CT scan after insertion of the applicator. High-dose-rate treatment planning was performed with standard loading patterns. The D2 cc structures in OARs were generated in three dimensional if the total equivalent dose in 2 Gy exceeded our defined dose limits (hot spot). The location of D2 cc hot spot was defined as the center of the largest D2 cc fragment. The relationship between the hot spot and the applicator position was reported in Digital Imaging and Communication in Medicine coordinates. The location of sigmoid, small bowel, and bladder D2 cc hot spots was around the endocervix: The mean location of sigmoid hot spot for lateral view was 1.6 cm posteriorly and 2.3 cm superiorly (Y, 1.6 and Z, 2.3), small bowel was 1.6 cm anteriorly and 2.7 cm superiorly (Y, -1.6 and Z, 2.7). The mean location of bladder hot spot was 1.6 cm anteriorly and 1.6 cm superiorly (Y, -1.6 and Z, 1.6). These hot spots were near the plane of Point A (X, 2.0 or -2.0; Y, 0; and Z, 2.0). The mean location of rectal hot spot was 1.6 cm posteriorly and 1.9 cm inferiorly (Y, 1.6 and Z, -1.9). D2 cc hot spot was affected by uterine wall thickness, uterine tandem position, fibroids, bladder fullness, bowel gas, and vaginal packing. Because of the location of the D2 cc hot spots, larger tumors present a challenge for adequate tumor coverage with a conventional brachytherapy applicator without an interstitial implant. Additionally, anatomic factors were identified which affect the D2 cc hot spot in OARs. Copyright © 2014 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  15. Is isomerism a risk factor for intestinal volvulus?

    PubMed

    Landisch, Rachel M; Loomba, Rohit S; Salazar, Jose H; Buelow, Matthew W; Frommelt, Michele; Anderson, Robert H; Wagner, Amy J

    2018-03-06

    Isomerism, or heterotaxy syndrome, affects many organ systems anatomically and functionally. Intestinal malrotation is common in patients with isomerism. Despite a low reported risk of volvulus, some physicians perform routine screening and prophylactic Ladd procedures on asymptomatic patients with isomerism who are found to have intestinal malrotation. The primary aim of this study was to determine if isomerism is an independent risk factor for volvulus. Kid's Inpatient Database data from 1997 to 2012 was utilized for this study. Characteristics of admissions with and without isomerism were compared with a particular focus on intestinal malrotation, volvulus, and Ladd procedure. A logistic regression was conducted to determine independent risk factors for volvulus with respect to isomerism. 15,962,403 inpatient admissions were included in the analysis, of which 7970 (0.05%) patients had isomerism, and 6 patients (0.1%) developed volvulus. Isomerism was associated with a 52-fold increase in the odds of intestinal malrotation by univariate analysis. Of 251 with isomerism and intestinal malrotation, only 2.4% experienced volvulus. Logistic regression demonstrated that isomerism was not an independent risk factor for volvulus. Isomerism is associated with an increased risk of intestinal malrotation but is not an independent risk factor for volvulus. Prognosis study. Level III. Copyright © 2018 Elsevier Inc. All rights reserved.

  16. Determination of correction factors in beta radiation beams using Monte Carlo method.

    PubMed

    Polo, Ivón Oramas; Santos, William de Souza; Caldas, Linda V E

    2018-06-15

    The absorbed dose rate is the main characterization quantity for beta radiation. The extrapolation chamber is considered the primary standard instrument. To determine absorbed dose rates in beta radiation beams, it is necessary to establish several correction factors. In this work, the correction factors for the backscatter due to the collecting electrode and to the guard ring, and the correction factor for Bremsstrahlung in beta secondary standard radiation beams are presented. For this purpose, the Monte Carlo method was applied. The results obtained are considered acceptable, and they agree within the uncertainties. The differences between the backscatter factors determined by the Monte Carlo method and those of the ISO standard were 0.6%, 0.9% and 2.04% for 90 Sr/ 90 Y, 85 Kr and 147 Pm sources respectively. The differences between the Bremsstrahlung factors determined by the Monte Carlo method and those of the ISO were 0.25%, 0.6% and 1% for 90 Sr/ 90 Y, 85 Kr and 147 Pm sources respectively. Copyright © 2018 Elsevier Ltd. All rights reserved.

  17. Anatomical approach to permanent His bundle pacing: Optimizing His bundle capture.

    PubMed

    Vijayaraman, Pugazhendhi; Dandamudi, Gopi

    2016-01-01

    Permanent His bundle pacing is a physiological alternative to right ventricular pacing. In this article we describe our approach to His bundle pacing in patients with AV nodal and intra-Hisian conduction disease. It is essential for the implanters to understand the anatomic variations of the His bundle course and its effect on the type of His bundle pacing achieved. We describe several case examples to illustrate our anatomical approach to permanent His bundle pacing in this article. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. [History of Japanese Committee for Anatomical Nomenclature].

    PubMed

    Kimura, Kunihiko

    2008-12-01

    This paper records a history of the Japanese Committee of Anatomical Nomenclature since 1990, as a supplement to the previous report (1991), explains a progressing of the edition of Japanese medical terms by the Japanese Association of Medical Sciences and the Ministry of Education, Sciences and Culture, and points out of some problems on terms in Japanese.

  19. Designing learning spaces for interprofessional education in the anatomical sciences.

    PubMed

    Cleveland, Benjamin; Kvan, Thomas

    2015-01-01

    This article explores connections between interprofessional education (IPE) models and the design of learning spaces for undergraduate and graduate education in the anatomical sciences and other professional preparation. The authors argue that for IPE models to be successful and sustained they must be embodied in the environment in which interprofessional learning occurs. To elaborate these arguments, two exemplar tertiary education facilities are discussed: the Charles Perkins Centre at the University of Sydney for science education and research, and Victoria University's Interprofessional Clinic in Wyndham for undergraduate IPE in health care. Backed by well-conceived curriculum and pedagogical models, the architectures of these facilities embody the educational visions, methods, and practices they were designed to support. Subsequently, the article discusses the spatial implications of curriculum and pedagogical change in the teaching of the anatomical sciences and explores how architecture might further the development of IPE models in the field. In conclusion, it is argued that learning spaces should be designed and developed (socially) with the expressed intention of supporting collaborative IPE models in health education settings, including those in the anatomical sciences. © 2015 American Association of Anatomists.

  20. Return-to-activity after anatomical reconstruction of acute high-grade acromioclavicular separation.

    PubMed

    Saier, T; Plath, J E; Beitzel, K; Minzlaff, P; Feucht, J M; Reuter, S; Martetschläger, F; Imhoff, Andreas B; Aboalata, M; Braun, S

    2016-04-02

    To evaluate return-to-activity (RtA) after anatomical reconstruction of acute high-grade acromioclavicular joint (ACJ) separation. A total of 42 patients with anatomical reconstruction of acute high-grade ACJ-separation (Rockwood Type V) were surveyed to determine RtA at a mean 31 months follow-up (f-u). Sports disciplines, intensity, level of competition, participation in overhead and/or contact sports, as well as activity scales (DASH-Sport-Module, Tegner Activity Scale) were evaluated. Functional outcome evaluation included Constant score and QuickDASH. All patients (42/42) participated in sporting activities at f-u. Neither participation in overhead/contact sports, nor level of activity declined significantly (n.s.). 62 % (n = 26) of patients reported subjective sports specific ACJ integrity to be at least the same as prior to the trauma. Sporting intensity (hours/week: 7.3 h to 5.4 h, p = .004) and level of competition (p = .02) were reduced. If activity changed, in 50 % other reasons but clinical symptoms/impairment were named for modified behavior. QuickDASH (mean 6, range 0-54, SD 11) and DASH-Sport-Module (mean 6, range 0-56, SD 13) revealed only minor disabilities at f-u. Over time Constant score improved significant to an excellent score (mean 94, range 86-100, SD 4; p < .001). Functional outcome was not correlated with RtA (n.s.). All patients participated in sporting activities after anatomical reconstruction of high-grade (Rockwood Type V) ACJ-separation. With a high functional outcome there was no significant change in activity level (Tegner) and participation in overhead and/or contact sports observed. There was no correlation between functional outcome and RtA. Limiting, there were alterations in time spent for sporting activities and level of competition observed. But in 50 % those were not related to ACJ symptoms/impairment. Unrelated to successful re-established integrity and function of the ACJ it should be considered that

  1. Hemispheric Asymmetry of Human Brain Anatomical Network Revealed by Diffusion Tensor Tractography

    PubMed Central

    Liu, Yaou; Duan, Yunyun; Li, Kuncheng

    2015-01-01

    The topological architecture of the cerebral anatomical network reflects the structural organization of the human brain. Recently, topological measures based on graph theory have provided new approaches for quantifying large-scale anatomical networks. However, few studies have investigated the hemispheric asymmetries of the human brain from the perspective of the network model, and little is known about the asymmetries of the connection patterns of brain regions, which may reflect the functional integration and interaction between different regions. Here, we utilized diffusion tensor imaging to construct binary anatomical networks for 72 right-handed healthy adult subjects. We established the existence of structural connections between any pair of the 90 cortical and subcortical regions using deterministic tractography. To investigate the hemispheric asymmetries of the brain, statistical analyses were performed to reveal the brain regions with significant differences between bilateral topological properties, such as degree of connectivity, characteristic path length, and betweenness centrality. Furthermore, local structural connections were also investigated to examine the local asymmetries of some specific white matter tracts. From the perspective of both the global and local connection patterns, we identified the brain regions with hemispheric asymmetries. Combined with the previous studies, we suggested that the topological asymmetries in the anatomical network may reflect the functional lateralization of the human brain. PMID:26539535

  2. Variation in stem anatomical characteristics of Campanuloideae species in relation to evolutionary history and ecological preferences.

    PubMed

    Schweingruber, Fritz Hans; Ríha, Pavel; Doležal, Jiří

    2014-01-01

    The detailed knowledge of plant anatomical characters and their variation among closely related taxa is key to understanding their evolution and function. We examined anatomical variation in 46 herbaceous taxa from the subfamily Campanuloideae (Campanulaceae) to link this information with their phylogeny, ecology and comparative material of 56 woody tropical taxa from the subfamily Lobelioideae. The species studied covered major environmental gradients from Mediterranean to Arctic zones, allowing us to test hypotheses on the evolution of anatomical structure in relation to plant competitive ability and ecological preferences. To understand the evolution of anatomical diversity, we reconstructed the phylogeny of studied species from nucleotide sequences and examined the distribution of anatomical characters on the resulting phylogenetic tree. Redundancy analysis, with phylogenetic corrections, was used to separate the evolutionary inertia from the adaptation to the environment. A large anatomical diversity exists within the Campanuloideae. Traits connected with the quality of fibres were the most congruent with phylogeny, and the Rapunculus 2 ("phyteumoid") clade was especially distinguished by a number of characters (absence of fibres, pervasive parenchyma, type of rays) from two other clades (Campanula s. str. and Rapunculus 1) characterized by the dominance of fibres and the absence of parenchyma. Septate fibres are an exclusive trait in the Lobelioideae, separating it clearly from the Campanuloideae where annual rings, pervasive parenchyma and crystals in the phellem are characteristic features. Despite clear phylogenetic inertia in the anatomical features studied, the ecological attributes and plant height had a significant effect on anatomical divergence. From all three evolutionary clades, the taller species converged towards similar anatomical structure, characterized by a smaller number of early wood vessels of large diameter, thinner cell-walls and

  3. Variation in Stem Anatomical Characteristics of Campanuloideae Species in Relation to Evolutionary History and Ecological Preferences

    PubMed Central

    Schweingruber, Fritz Hans; Říha, Pavel; Doležal, Jiří

    2014-01-01

    Background The detailed knowledge of plant anatomical characters and their variation among closely related taxa is key to understanding their evolution and function. We examined anatomical variation in 46 herbaceous taxa from the subfamily Campanuloideae (Campanulaceae) to link this information with their phylogeny, ecology and comparative material of 56 woody tropical taxa from the subfamily Lobelioideae. The species studied covered major environmental gradients from Mediterranean to Arctic zones, allowing us to test hypotheses on the evolution of anatomical structure in relation to plant competitive ability and ecological preferences. Methodology/Principal Findings To understand the evolution of anatomical diversity, we reconstructed the phylogeny of studied species from nucleotide sequences and examined the distribution of anatomical characters on the resulting phylogenetic tree. Redundancy analysis, with phylogenetic corrections, was used to separate the evolutionary inertia from the adaptation to the environment. A large anatomical diversity exists within the Campanuloideae. Traits connected with the quality of fibres were the most congruent with phylogeny, and the Rapunculus 2 (“phyteumoid”) clade was especially distinguished by a number of characters (absence of fibres, pervasive parenchyma, type of rays) from two other clades (Campanula s. str. and Rapunculus 1) characterized by the dominance of fibres and the absence of parenchyma. Septate fibres are an exclusive trait in the Lobelioideae, separating it clearly from the Campanuloideae where annual rings, pervasive parenchyma and crystals in the phellem are characteristic features. Conclusions/Significance Despite clear phylogenetic inertia in the anatomical features studied, the ecological attributes and plant height had a significant effect on anatomical divergence. From all three evolutionary clades, the taller species converged towards similar anatomical structure, characterized by a smaller number

  4. Anatomical predisposition of the ankle joint for lateral sprain or lateral malleolar fracture evaluated by radiographic measurements.

    PubMed

    Lee, Kyoung Min; Chung, Chin Youb; Sung, Ki Hyuk; Lee, SeungYeol; Kim, Tae Gyun; Choi, Young; Jung, Ki Jin; Kim, Yeon Ho; Koo, Seung Bum; Park, Moon Seok

    2015-01-01

    Injury mechanism and the amount of force are important factors determining whether a fracture or sprain occurs at the time of an ankle inversion injury. However, the anatomical differences between the ankle fracture and sprain have not been investigated sufficiently. This study was performed to investigate whether an anatomical predisposition of the ankle joint results in a lateral malleolar fracture or lateral ankle sprain. Two groups of consecutive patients, one with lateral malleolar fracture (274 patients, mean age 49.0 years) and the other with lateral ankle sprain (400 patients, mean age 38.4 years), were evaluated. Ankle radiographs were examined for 7 measures: distal tibial articular surface (DTAS) angle, bimalleolar tilt (BT), medial malleolar relative length (MMRL), lateral malleolar relative length (LMRL), medial malleolar slip angle (MMSA), anterior inclination of tibia (AI), and fibular position (FP). After an interobserver reliability test, the radiographic measurements were compared between the 2 groups. Linear regression analysis was performed to correct for age and sex effects between the groups. The fracture group and the sprain group showed significant differences in BT (P = .001), MMSA (P < .001), AI (P = .023), and FP (P < .001). In multiple regression analysis, after adjusting for age and sex effects, fracture and sprain groups showed a significant difference in BT (P = .001), MMRL (P < .001), MMSA (P < .001), and FP (P < .001). The lateral malleolar fracture group tended to show more bony constraint than that of the lateral ankle sprain group. Further 3-dimensional assessment of the bony structure and subsequent biomechanical studies are needed to elucidate the mechanism of injury according to the various types of ankle fractures and ankle sprain. Level III, retrospective comparative study. © The Author(s) 2014.

  5. The posterior auricular muscle: a useful anatomical landmark for otoplasty.

    PubMed

    Stephen, C; Lowrie, A G

    2017-05-01

    The correct anatomical placement of conchomastoid sutures during suture otoplasty can sometimes prove challenging. If the suture vector is inaccurate, reduction can be difficult and this may lead to malrotation of the pinna. This paper describes the adoption of the auricularis posterior muscle, which runs from the mastoid to the concha and whose function is to adduct the pinna, as a marker for conchomastoid suture placement. The muscle is easily identified and dissected, providing a landmark for the placement of sutures onto the adjacent concha and mastoid fascia. This allows for an anatomical reduction of the pinna. It is believed that this approach will prove useful to the otoplasty surgeon.

  6. Determination of Parachute Joint Factors using Seam and Joint Testing

    NASA Technical Reports Server (NTRS)

    Mollmann, Catherine

    2015-01-01

    This paper details the methodology for determining the joint factor for all parachute components. This method has been successfully implemented on the Capsule Parachute Assembly System (CPAS) for the NASA Orion crew module for use in determining the margin of safety for each component under peak loads. Also discussed are concepts behind the joint factor and what drives the loss of material strength at joints. The joint factor is defined as a "loss in joint strength...relative to the basic material strength" that occurs when "textiles are connected to each other or to metals." During the CPAS engineering development phase, a conservative joint factor of 0.80 was assumed for each parachute component. In order to refine this factor and eliminate excess conservatism, a seam and joint testing program was implemented as part of the structural validation. This method split each of the parachute structural joints into discrete tensile tests designed to duplicate the loading of each joint. Breaking strength data collected from destructive pull testing was then used to calculate the joint factor in the form of an efficiency. Joint efficiency is the percentage of the base material strength that remains after degradation due to sewing or interaction with other components; it is used interchangeably with joint factor in this paper. Parachute materials vary in type-mainly cord, tape, webbing, and cloth -which require different test fixtures and joint sample construction methods. This paper defines guidelines for designing and testing samples based on materials and test goals. Using the test methodology and analysis approach detailed in this paper, the minimum joint factor for each parachute component can be formulated. The joint factors can then be used to calculate the design factor and margin of safety for that component, a critical part of the design verification process.

  7. Frequency of palmaris longus absence and its association with other anatomical variations in the Egyptian population.

    PubMed

    Raouf, Hoda Abdel; Kader, Ghada Abdel; Jaradat, Ahmed; Dharap, Amol; Fadel, Raouf; Salem, Abdel Halim

    2013-07-01

    The palmaris longus (PL) is one of the most variable muscles in the human body. Racial differences in its variation have been documented. Several studies have attempted to correlate PL absence with other anatomical variations. This study was conducted to determine the prevalence of absence of PL, correlate it with gender and body side and to determine its association with other anatomical variations in the Egyptian population. The presence of PL was clinically determined in 386 Egyptians using the standard technique. All subjects were examined for the presence of the flexor digitorum superficialis (FDS) to the fifth finger. Allen's test was done to assess the completeness of the superficial palmar arch (SPA). The overall prevalence of absence of the PL in Egyptian subjects was 50.8%. There was no significant difference in PL absence with regard to the body side but a significant difference was seen as regards gender and when bilateral absence of PL was compared to its unilateral absence. Absence of FDS tendon to the fifth finger was seen in 1.3% subjects. There was no association between the absence of the FDS tendon to the fifth finger and either presence or absence of PL and also between the absence of PL and the incompleteness of SPA in both genders. In conclusion, the prevalence of absence of PL in the Egyptian population represents one of the highest rates of absence to be reported for this muscle, which is significantly different from that in other ethnic groups. Copyright © 2013 Wiley Periodicals, Inc.

  8. The Adult Mouse Anatomical Dictionary: a tool for annotating and integrating data

    PubMed Central

    Hayamizu, Terry F; Mangan, Mary; Corradi, John P; Kadin, James A; Ringwald, Martin

    2005-01-01

    We have developed an ontology to provide standardized nomenclature for anatomical terms in the postnatal mouse. The Adult Mouse Anatomical Dictionary is structured as a directed acyclic graph, and is organized hierarchically both spatially and functionally. The ontology will be used to annotate and integrate different types of data pertinent to anatomy, such as gene expression patterns and phenotype information, which will contribute to an integrated description of biological phenomena in the mouse. PMID:15774030

  9. Improving anatomical mapping of complexly deformed anatomy for external beam radiotherapy and brachytherapy dose accumulation in cervical cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vásquez Osorio, Eliana M., E-mail: e.vasquezosorio@erasmusmc.nl; Kolkman-Deurloo, Inger-Karine K.; Schuring-Pereira, Monica

    the rigid transformation and nonrigid registration of all structures together (AST). Results: The rigid transformation achieved a good global alignment (mean outer anatomical correctness of 4.3 mm) but failed to align the deformed organs (mean inner anatomical correctness of 22.4 mm). Conversely, the AST registration produced a reasonable alignment for the organs (6.3 mm) but not for the surrounding region (16.9 mm). SW+VF registration achieved the best results for both regions (3.5 and 3.4 mm for the inner and outer anatomical correctness, respectively). All differences were significant (p < 0.02, Wilcoxon rank sum test). Additionally, optimization of the scope sizes determined that the method was robust for a large range of scope size values. Conclusions: The novel SW+VF method improved the mapping of large and complex deformations observed between EBRT and BT for cervical cancer patients. Future studies that quantify the mapping error in terms of dose errors are required to test the clinical applicability of dose accumulation by the SW+VF method.« less

  10. Anatomical basis of the liver hanging maneuver.

    PubMed

    Trotovsek, Blaz; Belghiti, Jacques; Gadzijev, Eldar M; Ravnik, Dean; Hribernik, Marija

    2005-01-01

    The anterior approach to right hepatectomy using the liver hanging maneuver without liver mobilization claims to be anatomically evaluated. During this procedure a 4 to 6-cm blind dissection between the inferior vena cava and the liver is performed. Short subhepatic veins, entering the inferior vena cava could be torn and a hemorrhage, difficult to control, could occur. On 100 corrosive casts of livers the anterior surface of the inferior vena cava was studied to evaluate the position, diameter and draining area of short subhepatic veins and inferior right hepatic vein. The width of the narrowest point on the planned route of blind dissection was determined. The average value of the narrowest point on the planned route of blind dissection was 8.7+/-2.3mm (range 2-15mm). The ideal angle of dissection being 0 degrees was found in 93% of cases. In 7% we found the angle of 5 degrees toward the right border of inferior vena cava to be the better choice. Our results show that liver hanging maneuver is a safe procedure. With the dissection in the proposed route the risk of disrupting short subhepatic veins is low (7%).

  11. Anatomical Modularity of Verbal Working Memory? Functional Anatomical Evidence from a Famous Patient with Short-Term Memory Deficits

    PubMed Central

    Paulesu, Eraldo; Shallice, Tim; Danelli, Laura; Sberna, Maurizio; Frackowiak, Richard S. J.; Frith, Chris D.

    2017-01-01

    Cognitive skills are the emergent property of distributed neural networks. The distributed nature of these networks does not necessarily imply a lack of specialization of the individual brain structures involved. However, it remains questionable whether discrete aspects of high-level behavior might be the result of localized brain activity of individual nodes within such networks. The phonological loop of working memory, with its simplicity, seems ideally suited for testing this possibility. Central to the development of the phonological loop model has been the description of patients with focal lesions and specific deficits. As much as the detailed description of their behavior has served to refine the phonological loop model, a classical anatomoclinical correlation approach with such cases falls short in telling whether the observed behavior is based on the functions of a neural system resembling that seen in normal subjects challenged with phonological loop tasks or whether different systems have taken over. This is a crucial issue for the cross correlation of normal cognition, normal physiology, and cognitive neuropsychology. Here we describe the functional anatomical patterns of JB, a historical patient originally described by Warrington et al. (1971), a patient with a left temporo-parietal lesion and selective short phonological store deficit. JB was studied with the H215O PET activation technique during a rhyming task, which primarily depends on the rehearsal system of the phonological loop. No residual function was observed in the left temporo-parietal junction, a region previously associated with the phonological buffer of working memory. However, Broca's area, the major counterpart of the rehearsal system, was the major site of activation during the rhyming task. Specific and autonomous activation of Broca's area in the absence of afferent inputs from the other major anatomical component of the phonological loop shows that a certain degree of functional

  12. Anatomical landmarks of radical prostatecomy.

    PubMed

    Stolzenburg, Jens-Uwe; Schwalenberg, Thilo; Horn, Lars-Christian; Neuhaus, Jochen; Constantinides, Costantinos; Liatsikos, Evangelos N

    2007-03-01

    In the present study, we review current literature and based on our experience, we present the anatomical landmarks of open and laparoscopic/endoscopic radical prostatectomy. A thorough literature search was performed with the Medline database on the anatomy and the nomenclature of the structures surrounding the prostate gland. The correct handling of puboprostatic ligaments, external urethral sphincter, prostatic fascias and neurovascular bundle is necessary for avoiding malfunction of the urogenital system after radical prostatectomy. When evaluating new prostatectomy techniques, we should always take into account both clinical and final oncological outcomes. The present review adds further knowledge to the existing "postprostatectomy anatomical hazard" debate. It emphasizes upon the role of the puboprostatic ligaments and the course of the external urethral sphincter for urinary continence. When performing an intrafascial nerve sparing prostatectomy most urologists tend to approach as close to the prostatic capsula as possible, even though there is no concurrence regarding the nomenclature of the surrounding fascias and the course of the actual neurovascular bundles. After completion of an intrafascial technique the specimen does not contain any periprostatic tissue and thus the detection of pT3a disease is not feasible. This especially becomes problematic if the tumour reaches the resection margin. Nerve sparing open and laparoscopic radical prostatectomy should aim in maintaining sexual function, recuperating early continence after surgery, without hindering the final oncological outcome to the procedure. Despite the different approaches for radical prostatectomy the key for better results is the understanding of the anatomy of the bladder neck and the urethra.

  13. Depressive Symptoms, Anatomical Region, and Clinical Outcomes for Patients Seeking Outpatient Physical Therapy for Musculoskeletal Pain

    PubMed Central

    Coronado, Rogelio A.; Beneciuk, Jason M.; Valencia, Carolina; Werneke, Mark W.; Hart, Dennis L.

    2011-01-01

    Background Clinical guidelines advocate the routine identification of depressive symptoms for patients with pain in the lumbar or cervical spine, but not for other anatomical regions. Objective The purpose of this study was to investigate the prevalence and impact of depressive symptoms for patients with musculoskeletal pain across different anatomical regions. Design This was a prospective, associational study. Methods Demographic, clinical, depressive symptom (Symptom Checklist 90–Revised), and outcome data were collected by self-report from a convenience sample of 8,304 patients. Frequency of severe depressive symptoms was assessed by chi-square analysis for demographic and clinical variables. An analysis of variance examined the influence of depressive symptoms and anatomical region on intake pain intensity and functional status. Separate hierarchical multiple regression models by anatomical region examined the influence of depressive symptoms on clinical outcomes. Results Prevalence of severe depression was higher in women, in industrial and pain clinics, and in patients who reported chronic pain or prior surgery. Lower prevalence rates were found in patients older than 65 years and those who had upper- or lower-extremity pain. Depressive symptoms had a moderate to large effect on pain ratings (Cohen d=0.55–0.87) and a small to large effect on functional status (Cohen d=0.28–0.95). In multivariate analysis, depressive symptoms contributed additional variance to pain intensity and functional status for all anatomical locations, except for discharge values for the cervical region. Conclusions Rates of depressive symptoms varied slightly based on anatomical region of musculoskeletal pain. Depressive symptoms had a consistent detrimental influence on outcomes, except on discharge scores for the cervical anatomical region. Expanding screening recommendations for depressive symptoms to include more anatomical regions may be indicated in physical therapy

  14. Characterization of Capsicum species using anatomical and molecular data.

    PubMed

    Dias, G B; Gomes, V M; Moraes, T M S; Zottich, U P; Rabelo, G R; Carvalho, A O; Moulin, M; Gonçalves, L S A; Rodrigues, R; Da Cunha, M

    2013-02-28

    Capsicum species are frequently described in terms of genetic divergence, considering morphological, agronomic, and molecular databases. However, descriptions of genetic differences based on anatomical characters are rare. We examined the anatomy and the micromorphology of vegetative and reproductive organs of several Capsicum species. Four Capsicum accessions representing the species C. annuum var. annuum, C. baccatum var. pendulum, C. chinense, and C. frutescens were cultivated in a greenhouse; leaves, fruits and seeds were sampled and their organ structure analyzed by light and scanning electronic microscopy. Molecular accession characterization was made using ISSR markers. Polymorphism was observed among tector trichomes and also in fruit color and shape. High variability among accessions was detected by ISSR markers. Despite the species studied present a wide morphological and molecular variability that was not reflected by anatomical features.

  15. Anatomical frame plate osteosynthesis in Ada-Miller Type 2 or 4 scapula fractures.

    PubMed

    Esenkaya, İrfan; Ünay, Koray

    2011-01-01

    The aim of this prospective study was to evaluate the results of anatomical frame plate osteosynthesis in patients with Ada and Miller Type 2 or 4 scapula fractures. Eleven Ada and Miller Type 2 or 4 scapula fractures in nine patients were treated with anatomical frame plate osteosynthesis. The mean follow-up time was 39.8 (12-77) months. The results were evaluated using the Herscovici score. No complications, such as neurovascular injury, postoperative hematoma, infection, delayed wound healing, implant failure, delayed union, or nonunion occurred. Based on the Herscovici score, the results were excellent. Osteosynthesis with anatomical frame plates appears to be a safe method that allows early range of motion and that provides excellent results in Ada and Miller Type 2 or 4 scapula fractures.

  16. Teaching of anatomical sciences: A blended learning approach.

    PubMed

    Khalil, Mohammed K; Abdel Meguid, Eiman M; Elkhider, Ihsan A

    2018-04-01

    Blended learning is the integration of different learning approaches, new technologies, and activities that combine traditional face-to-face teaching methods with authentic online methodologies. Although advances in educational technology have helped to expand the selection of different pedagogies, the teaching of anatomical sciences has been challenged by implementation difficulties and other limitations. These challenges are reported to include lack of time, costs, and lack of qualified teachers. Easy access to online information and advances in technology make it possible to resolve these limitations by adopting blended learning approaches. Blended learning strategies have been shown to improve students' academic performance, motivation, attitude, and satisfaction, and to provide convenient and flexible learning. Implementation of blended learning strategies has also proved cost effective. This article provides a theoretical foundation for blended learning and proposes a validated framework for the design of blended learning activities in the teaching and learning of anatomical sciences. Clin. Anat. 31:323-329, 2018. © 2018 Wiley Periodicals, Inc. © 2018 Wiley Periodicals, Inc.

  17. Measuring quality in anatomic pathology.

    PubMed

    Raab, Stephen S; Grzybicki, Dana Marie

    2008-06-01

    This article focuses mainly on diagnostic accuracy in measuring quality in anatomic pathology, noting that measuring any quality metric is complex and demanding. The authors discuss standardization and its variability within and across areas of care delivery and efforts involving defining and measuring error to achieve pathology quality and patient safety. They propose that data linking error to patient outcome are critical for developing quality improvement initiatives targeting errors that cause patient harm in addition to using methods of root cause analysis, beyond those traditionally used in cytologic-histologic correlation, to assist in the development of error reduction and quality improvement plans.

  18. [Attention deficit hyperactivity disorder: its aetiological factors and endophenotypes].

    PubMed

    Ferrando-Lucas, M T

    2006-02-13

    Attention deficit hyperactivity disorder (ADHD) is one of the most frequent reasons for patients' visits in everyday practice. The academic and social distortion it produces in those affected by this condition have turned it into a subject that is receiving growing attention from researchers and the progress being made in the neurosciences means that it is being investigated from a wide range of approaches. Genetic aspects, as well as anatomical and neurobiological markers, are some of the new lines of research that are being used together with a more precise neuropsychological approach to obtain a more comprehensive understanding of ADHD. Such knowledge now involves genetic factors, centres of cognitive disorder and the search for endophenotypes that account for the complexity of its semiology. The primary cognitive deficits in ADHD appear to be the underlying problem in the disorder, special attention also being given to both the executive functions and the distortion of the capacity to inhibit responses. Furthermore, anatomical factors have been related to the type and severity of the symptomatology of the disorder, although the dispersion of the results and the genetic findings that focus their attention on anomalous alleles for dopamine transporting and receptor genes suggest that the disorder is more complex. The different aetiological factors that have been associated to the disorder and the variability in the semiology of ADHD place us before a situation in disarray; the determination of endophenotypes, however, could enable us carry out a better systematisation of a disorder that is currently still a long way from being fully understood.

  19. An interactive three-dimensional virtual body structures system for anatomical training over the internet.

    PubMed

    Temkin, Bharti; Acosta, Eric; Malvankar, Ameya; Vaidyanath, Sreeram

    2006-04-01

    The Visible Human digital datasets make it possible to develop computer-based anatomical training systems that use virtual anatomical models (virtual body structures-VBS). Medical schools are combining these virtual training systems and classical anatomy teaching methods that use labeled images and cadaver dissection. In this paper we present a customizable web-based three-dimensional anatomy training system, W3D-VBS. W3D-VBS uses National Library of Medicine's (NLM) Visible Human Male datasets to interactively locate, explore, select, extract, highlight, label, and visualize, realistic 2D (using axial, coronal, and sagittal views) and 3D virtual structures. A real-time self-guided virtual tour of the entire body is designed to provide detailed anatomical information about structures, substructures, and proximal structures. The system thus facilitates learning of visuospatial relationships at a level of detail that may not be possible by any other means. The use of volumetric structures allows for repeated real-time virtual dissections, from any angle, at the convenience of the user. Volumetric (3D) virtual dissections are performed by adding, removing, highlighting, and labeling individual structures (and/or entire anatomical systems). The resultant virtual explorations (consisting of anatomical 2D/3D illustrations and animations), with user selected highlighting colors and label positions, can be saved and used for generating lesson plans and evaluation systems. Tracking users' progress using the evaluation system helps customize the curriculum, making W3D-VBS a powerful learning tool. Our plan is to incorporate other Visible Human segmented datasets, especially datasets with higher resolutions, that make it possible to include finer anatomical structures such as nerves and small vessels. (c) 2006 Wiley-Liss, Inc.

  20. Digital preservation of anatomical variation: 3D-modeling of embalmed and plastinated cadaveric specimens using uCT and MRI.

    PubMed

    Moore, Colin W; Wilson, Timothy D; Rice, Charles L

    2017-01-01

    Anatomy educators have an opportunity to teach anatomical variations as a part of medical and allied health curricula using both cadaveric and three-dimensional (3D) digital models of these specimens. Beyond published cadaveric case reports, anatomical variations identified during routine gross anatomy dissection can be powerful teaching tools and a medium to discuss several anatomical sub-disciplines from embryology to medical imaging. The purpose of this study is to document how cadaveric anatomical variation identified during routine dissection can be scanned using medical imaging techniques to create two-dimensional axial images and interactive 3D models for teaching and learning of anatomical variations. Three cadaveric specimens (2 formalin embalmed, 1 plastinated) depicting anatomical variations and an embryological malformation were scanned using magnetic resonance imaging (MRI) and micro-computed tomography (μCT) for visualization in cross-section and for creation of 3D volumetric models. Results provide educational options to enable visualization and facilitate learning of anatomical variations from cross-sectional scans. Furthermore, the variations can be highlighted, digitized, modeled and manipulated using 3D imaging software and viewed in the anatomy laboratory in conjunction with traditional anatomical dissection. This study provides an example for anatomy educators to teach and describe anatomical variations in the undergraduate medical curriculum. Copyright © 2016 Elsevier GmbH. All rights reserved.

  1. Investigations of Anatomical Variations of the Thorax and Heart, and Anatomical Knowledge for First Year Medical Dental and Podiatry Students

    ERIC Educational Resources Information Center

    Verenna, Anne-Marie

    2013-01-01

    The universal presence of anatomy in healthcare professions is undeniable. It is a cornerstone to each of the clinical and basic sciences. Therefore, further expansion of current anatomical knowledge and effective methods to teach anatomy is essential. In this work, the relationship of the dorsal scapular artery with the trunks of the brachial…

  2. The scala vestibuli for cochlear implantation. An anatomic study.

    PubMed

    Gulya, A J; Steenerson, R L

    1996-02-01

    Traditionally, cochlear implantation has used the scala tympani (ST) for electrode insertion. When faced with ST ossification, the surgeon may elect to drill out the cochlea to accomplish partial electrode insertion. Theoretically, another option in this situation is to insert the electrode into the scala vestibuli (SV). To determine whether or not the dimensions of the SV are sufficient to accommodate an electrode array so as to assess the feasibility of SV cochlear implantation. The study of 20 normal human temporal bones, comparing the maximum diameter and surface area of the ST with those of the combined SV and scala media. The dimensions of the SV and scala media were comparable to those of the ST and appeared sufficient to accommodate a cochlear implant electrode array. It appears that the combination of SV and scala media is a viable alternative route for electrode insertion, at least on the basis of anatomic dimensions, in those cases in which the ST is obliterated.

  3. Evidence for a genetic discontinuity between Neandertals and 24,000-year-old anatomically modern Europeans.

    PubMed

    Caramelli, David; Lalueza-Fox, Carles; Vernesi, Cristiano; Lari, Martina; Casoli, Antonella; Mallegni, Francesco; Chiarelli, Brunetto; Dupanloup, Isabelle; Bertranpetit, Jaume; Barbujani, Guido; Bertorelle, Giorgio

    2003-05-27

    During the late Pleistocene, early anatomically modern humans coexisted in Europe with the anatomically archaic Neandertals for some thousand years. Under the recent variants of the multiregional model of human evolution, modern and archaic forms were different but related populations within a single evolving species, and both have contributed to the gene pool of current humans. Conversely, the Out-of-Africa model considers the transition between Neandertals and anatomically modern humans as the result of a demographic replacement, and hence it predicts a genetic discontinuity between them. Following the most stringent current standards for validation of ancient DNA sequences, we typed the mtDNA hypervariable region I of two anatomically modern Homo sapiens sapiens individuals of the Cro-Magnon type dated at about 23 and 25 thousand years ago. Here we show that the mtDNAs of these individuals fall well within the range of variation of today's humans, but differ sharply from the available sequences of the chronologically closer Neandertals. This discontinuity is difficult to reconcile with the hypothesis that both Neandertals and early anatomically modern humans contributed to the current European gene pool.

  4. Investigation on location dependent detectability in cone beam CT images with uniform and anatomical backgrounds

    NASA Astrophysics Data System (ADS)

    Han, Minah; Baek, Jongduk

    2017-03-01

    We investigate location dependent lesion detectability of cone beam computed tomography images for different background types (i.e., uniform and anatomical), image planes (i.e., transverse and longitudinal) and slice thicknesses. Anatomical backgrounds are generated using a power law spectrum of breast anatomy, 1/f3. Spherical object with a 5mm diameter is used as a signal. CT projection data are acquired by the forward projection of uniform and anatomical backgrounds with and without the signal. Then, projection data are reconstructed using the FDK algorithm. Detectability is evaluated by a channelized Hotelling observer with dense difference-of-Gaussian channels. For uniform background, off-centered images yield higher detectability than iso-centered images for the transverse plane, while for the longitudinal plane, detectability of iso-centered and off-centered images are similar. For anatomical background, off-centered images yield higher detectability for the transverse plane, while iso-centered images yield higher detectability for the longitudinal plane, when the slice thickness is smaller than 1.9mm. The optimal slice thickness is 3.8mm for all tasks, and the transverse plane at the off-center (iso-center and off-center) produces the highest detectability for uniform (anatomical) background.

  5. Assessing the effectiveness of 30% sodium chloride aqueous solution for the preservation of fixed anatomical specimens: a 5-year follow-up study.

    PubMed

    de Oliveira, Fabrício Singaretti

    2014-07-01

    Anatomical specimens used in human or veterinary anatomy laboratories are usually prepared with formaldehyde (a cancerous and teratogenic substance), glycerin (an expensive and viscous fluid), or ethanol (which is flammable). This research aimed to verify the viability of an aqueous 30% sodium chloride solution for preservation of anatomical specimens previously fixed with formaldehyde. Anatomical specimens of ruminant, carnivorous, equine, swine and birds were used. All were previously fixed with an aqueous 20% formaldehyde solution and held for 7 days in a 10% aqueous solution of the same active ingredient. During the first phase of the experiment, small specimens of animal tissue previously fixed in formaldehyde were distributed in vials with different concentrations of formaldehyde, with or without 30% sodium chloride solution, a group containing only 30% sodium chloride, and a control group containing only water. During this phase, no contamination was observed in any specimen containing 30% sodium chloride solution, whether alone or in combination with different concentrations of formaldehyde. In the second phase of the experiment, the 30% sodium chloride solution, found to be optimal in the first phase of the experiment, was tested for its long-term preservation properties. For a period of 5 years, the preserved specimens were evaluated three times a week for visual contamination, odors, and changes in color and texture. There was no visual contamination or decay found in any specimen. Furthermore, no strange odors, or changes in color or softness were noted. The 30% sodium chloride solution was determined to be effective in the preservation of anatomic specimens previously fixed in formaldehyde. © 2014 Anatomical Society.

  6. [Analysis of anatomical pieces preservation with polyester resin for human anatomy study].

    PubMed

    de Oliveira, Ítalo Martins; Mindêllo, Marcela Maria Aguiar; Martins, Yasmin de Oliveira; da Silva Filho, Antônio Ribeiro

    2013-01-01

    To evaluate the use of polyester resin in preserving anatomical specimens for the study of human anatomy. We used 150 anatomical specimens, comprised of unfixed (fresh), fixed in 10% formalin and vascular casts of organs injected with vinyl acetate and polyester resin. The solution used consisted of polyester resin with the diluent styrene monomer and catalyst (peroxol). After embedding in this solution, models in transparent resin were obtained, allowing full observation of structures and conservation of the specimens used. upon evaluation of the specimens, we observed a high degree of transparency, which promoted a complete visualization of structures with perfect preservation of the anatomy. The average time for the completion of the embedding was 48 hours. Only 14 specimens (9.3%) were lost during the preparation. Polyester resin can be used for preserving anatomical specimens for teaching human anatomy in a practical, aesthetic and durable way.

  7. Quantitative evaluation of brain development using anatomical MRI and diffusion tensor imaging☆

    PubMed Central

    Oishi, Kenichi; Faria, Andreia V.; Yoshida, Shoko; Chang, Linda; Mori, Susumu

    2013-01-01

    The development of the brain is structure-specific, and the growth rate of each structure differs depending on the age of the subject. Magnetic resonance imaging (MRI) is often used to evaluate brain development because of the high spatial resolution and contrast that enable the observation of structure-specific developmental status. Currently, most clinical MRIs are evaluated qualitatively to assist in the clinical decision-making and diagnosis. The clinical MRI report usually does not provide quantitative values that can be used to monitor developmental status. Recently, the importance of image quantification to detect and evaluate mild-to-moderate anatomical abnormalities has been emphasized because these alterations are possibly related to several psychiatric disorders and learning disabilities. In the research arena, structural MRI and diffusion tensor imaging (DTI) have been widely applied to quantify brain development of the pediatric population. To interpret the values from these MR modalities, a “growth percentile chart,” which describes the mean and standard deviation of the normal developmental curve for each anatomical structure, is required. Although efforts have been made to create such a growth percentile chart based on MRI and DTI, one of the greatest challenges is to standardize the anatomical boundaries of the measured anatomical structures. To avoid inter- and intra-reader variability about the anatomical boundary definition, and hence, to increase the precision of quantitative measurements, an automated structure parcellation method, customized for the neonatal and pediatric population, has been developed. This method enables quantification of multiple MR modalities using a common analytic framework. In this paper, the attempt to create an MRI- and a DTI-based growth percentile chart, followed by an application to investigate developmental abnormalities related to cerebral palsy, Williams syndrome, and Rett syndrome, have been introduced

  8. Longitudinal retention of anatomical knowledge in second-year medical students.

    PubMed

    Doomernik, Denise E; van Goor, Harry; Kooloos, Jan G M; Ten Broek, Richard P

    2017-06-01

    The Radboud University Medical Center has a problem-based, learner-oriented, horizontally, and vertically integrated medical curriculum. Anatomists and clinicians have noticed students' decreasing anatomical knowledge and the disability to apply knowledge in diagnostic reasoning and problem solving. In a longitudinal cohort, the retention of anatomical knowledge gained during the first year of medical school among second-year medical students was assessed. In May 2011, 346 medical students applied for the second-year gastro-intestinal (GI) tract course. The students were asked to participate in a reexamination of a selection of anatomical questions of an examination from October 2009. The examination consisted of a clinical anatomy case scenario and two computed tomography (CT) images of thorax and abdomen in an extended matching format. A total of 165 students were included for analysis. In 2011, students scored significantly lower for the anatomy examination compared to 2009 with a decline in overall examination score of 14.7% (±11.7%). Decrease in knowledge was higher in the radiological questions, compared to the clinical anatomy cases 17.5% (±13.6%) vs. 7.9% (±10.0%), respectively, d = 5.17. In both years, male students scored slightly better compared to female students, and decline of knowledge seems somewhat lower in male students (13.1% (±11.1%) vs. 15.5% (±12.0%), respectively), d = -0.21. Anatomical knowledge in the problem-oriented horizontal and vertical integrated medical curriculum, declined by approximately 15% 1.5 year after the initial anatomy course. The loss of knowledge in the present study is relative small compared to previous studies. Anat Sci Educ 10: 242-248. © 2016 American Association of Anatomists. © 2016 American Association of Anatomists.

  9. Pathology economic model tool: a novel approach to workflow and budget cost analysis in an anatomic pathology laboratory.

    PubMed

    Muirhead, David; Aoun, Patricia; Powell, Michael; Juncker, Flemming; Mollerup, Jens

    2010-08-01

    The need for higher efficiency, maximum quality, and faster turnaround time is a continuous focus for anatomic pathology laboratories and drives changes in work scheduling, instrumentation, and management control systems. To determine the costs of generating routine, special, and immunohistochemical microscopic slides in a large, academic anatomic pathology laboratory using a top-down approach. The Pathology Economic Model Tool was used to analyze workflow processes at The Nebraska Medical Center's anatomic pathology laboratory. Data from the analysis were used to generate complete cost estimates, which included not only materials, consumables, and instrumentation but also specific labor and overhead components for each of the laboratory's subareas. The cost data generated by the Pathology Economic Model Tool were compared with the cost estimates generated using relative value units. Despite the use of automated systems for different processes, the workflow in the laboratory was found to be relatively labor intensive. The effect of labor and overhead on per-slide costs was significantly underestimated by traditional relative-value unit calculations when compared with the Pathology Economic Model Tool. Specific workflow defects with significant contributions to the cost per slide were identified. The cost of providing routine, special, and immunohistochemical slides may be significantly underestimated by traditional methods that rely on relative value units. Furthermore, a comprehensive analysis may identify specific workflow processes requiring improvement.

  10. Determinants of expiratory flow limitation in healthy women during exercise.

    PubMed

    Dominelli, Paolo B; Guenette, Jordan A; Wilkie, Sabrina S; Foster, Glen E; Sheel, A William

    2011-09-01

    Expiratory flow limitation (EFL) can occur in healthy young women during exercise. We questioned whether the occurrence and severity of EFL were related to aerobic fitness or anatomical factors. Twenty-two healthy young (<40 yr) women performed a progressive cycle test to exhaustion. The subjects' maximum expiratory flow-volume curve was compiled from several effort-graded vital capacity maneuvers before and after exercise. The maximum expiratory flow-volume curve, along with inspiratory capacity maneuvers, was used to determine lung volumes and expiratory flows and to quantify EFL. To determine relative airway size, we used a ratio sensitive to both airway size and lung volume, called the dysanapsis ratio. The subjects were partitioned into two groups based upon the appearance of >5% EFL. Ten subjects showed EFL during exercise. Forced vital capacities (4.4 ± 0.4 vs 3.7 ± 0.4 L, P < 0.001) and forced expiratory flows for any given lung volume were significantly larger in the non-expiratory flow-limited (NEFL) group. The NEFL group's dysanapsis ratio was significantly larger than that of the EFL group (0.27 ± 0.06 vs 0.21 ± 0.04, respectively, P < 0.05), indicating larger airways in the NEFL group. There was no difference between the NEFL and EFL groups with respect to maximal aerobic capacity (50.8 ± 10.0 vs 46.7 ± 5.9 mL·kg(-1)·min(-1), respectively, P = 0.264). At peak exercise, the NEFL group had a significantly higher end-expiratory lung volume than the EFL group (40.1% ± 4.8% vs 33.7% ± 5.7% FVC, respectively, P < 0.05). We conclude that EFL in women can largely be explained by anatomical factors that influence the capacity to generate flow and volume during exercise rather than fitness per se.

  11. Anatomic Peculiarities of Pig and Human Liver.

    PubMed

    Nykonenko, Andriy; Vávra, Petr; Zonča, Pavel

    2017-02-01

    Many investigations on surgical methods and medical treatment are currently done on pigs. This is possible because the pig is sufficiently close genetically to humans. In recent years, progress in liver surgery has opened new possibilities in surgical treatment of liver diseases. Because the methods are relatively novel, various improvements are still needed, and it is thus helpful to conduct experimental surgeries on pig livers. We reviewed the literature to compare the anatomic and functional features of pig and human livers, information that will be of great importance for improving surgical techniques. During the literature review, we used various sources, such as PubMed, Scopus, and veterinary journals. Our results were summarized in diagrams to facilitate understanding of the vascular structure and biliary systems. We conclude that, although the shapes of the human and pig livers are quite different, the pig liver is divided into the same number of segments as the human liver, which also shows a common structure of the vascular system. Thus, with the anatomic and structural features of the pig liver taken into account, this animal model can be used in experimental hepatic surgery.

  12. Do the skills acquired by novice surgeons using anatomic dry models transfer effectively to the task of diagnostic knee arthroscopy performed on cadaveric specimens?

    PubMed

    Butler, Aaron; Olson, Tyson; Koehler, Ryan; Nicandri, Gregg

    2013-02-06

    The use of surgical simulation in orthopaedic education is increasing; however, its ideal place within the training curriculum remains unknown. The purpose of this study was to determine the effectiveness of training novice surgeons on an anatomic dry model of the knee prior to training them to perform diagnostic arthroscopy on cadaveric specimens. Fourteen medical students were randomly assigned to two groups. The experimental group was trained to perform diagnostic arthroscopy of the knee on anatomic dry models prior to training on cadaveric specimens. The control group was trained only on cadaveric specimens. Proficiency was assessed with use of a modified version of a previously validated objective assessment of arthroscopic skill, the Basic Arthroscopic Knee Skill Scoring System (BAKSSS). The mean number of trials required to attain minimal proficiency when performing diagnostic knee arthroscopy was compared between the groups. The cumulative transfer effectiveness ratio (CTER) was calculated to measure the transfer of skills acquired by the experimental group. The mean number of trials to demonstrate minimum proficiency was significantly lower in the experimental group (2.57) than in the control group (4.57) (p < 0.01). The mean time to demonstrate proficiency was also significantly less in the experimental group (37.51 minutes) than in the control group (60.48 minutes) (p < 0.01). The CTER of dry-model training for the task of performing diagnostic knee arthroscopy on cadaveric specimens was 0.2. Previous training utilizing an anatomic dry knee model resulted in improved proficiency for novice surgeons learning to perform diagnostic knee arthroscopy on cadaveric specimens. A CTER of 0.2 suggests that dry models can serve as a useful adjunct to cadaveric training for diagnostic knee arthroscopy but cannot entirely replace it within the orthopaedic curriculum. Further work is necessary to determine the optimal amount of training on anatomic dry models

  13. Factors Considered in Determining Educational Setting for Students with Emotional Disturbance

    ERIC Educational Resources Information Center

    Hoge, Matthew

    2013-01-01

    The present study identified factors influencing determination of educational setting for students with Emotional Disturbance (ED). Determination of most appropriate educational setting, a key provision of students' individualized education programs (IEP) continues to be one the most contentious issues in special education. Focus group interviews…

  14. Anatomical classification of breast sentinel lymph nodes using computed tomography-lymphography.

    PubMed

    Fujita, Tamaki; Miura, Hiroyuki; Seino, Hiroko; Ono, Shuichi; Nishi, Takashi; Nishimura, Akimasa; Hakamada, Kenichi; Aoki, Masahiko

    2018-05-03

    To evaluate the anatomical classification and location of breast sentinel lymph nodes, preoperative computed tomography-lymphography examinations were retrospectively reviewed for sentinel lymph nodes in 464 cases clinically diagnosed with node-negative breast cancer between July 2007 and June 2016. Anatomical classification was performed based on the numbers of lymphatic routes and sentinel lymph nodes, the flow direction of lymphatic routes, and the location of sentinel lymph nodes. Of the 464 cases reviewed, anatomical classification could be performed in 434 (93.5 %). The largest number of cases showed single route/single sentinel lymph node (n = 296, 68.2 %), followed by multiple routes/multiple sentinel lymph nodes (n = 59, 13.6 %), single route/multiple sentinel lymph nodes (n = 53, 12.2 %), and multiple routes/single sentinel lymph node (n = 26, 6.0 %). Classification based on the flow direction of lymphatic routes showed that 429 cases (98.8 %) had outward flow on the superficial fascia toward axillary lymph nodes, whereas classification based on the height of sentinel lymph nodes showed that 323 cases (74.4 %) belonged to the upper pectoral group of axillary lymph nodes. There was wide variation in the number of lymphatic routes and their branching patterns and in the number, location, and direction of flow of sentinel lymph nodes. It is clinically very important to preoperatively understand the anatomical morphology of lymphatic routes and sentinel lymph nodes for optimal treatment of breast cancer, and computed tomography-lymphography is suitable for this purpose.

  15. SU-C-207B-02: Maximal Noise Reduction Filter with Anatomical Structures Preservation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maitree, R; Guzman, G; Chundury, A

    Purpose: All medical images contain noise, which can result in an undesirable appearance and can reduce the visibility of anatomical details. There are varieties of techniques utilized to reduce noise such as increasing the image acquisition time and using post-processing noise reduction algorithms. However, these techniques are increasing the imaging time and cost or reducing tissue contrast and effective spatial resolution which are useful diagnosis information. The three main focuses in this study are: 1) to develop a novel approach that can adaptively and maximally reduce noise while preserving valuable details of anatomical structures, 2) to evaluate the effectiveness ofmore » available noise reduction algorithms in comparison to the proposed algorithm, and 3) to demonstrate that the proposed noise reduction approach can be used clinically. Methods: To achieve a maximal noise reduction without destroying the anatomical details, the proposed approach automatically estimated the local image noise strength levels and detected the anatomical structures, i.e. tissue boundaries. Such information was used to adaptively adjust strength of the noise reduction filter. The proposed algorithm was tested on 34 repeating swine head datasets and 54 patients MRI and CT images. The performance was quantitatively evaluated by image quality metrics and manually validated for clinical usages by two radiation oncologists and one radiologist. Results: Qualitative measurements on repeated swine head images demonstrated that the proposed algorithm efficiently removed noise while preserving the structures and tissues boundaries. In comparisons, the proposed algorithm obtained competitive noise reduction performance and outperformed other filters in preserving anatomical structures. Assessments from the manual validation indicate that the proposed noise reduction algorithm is quite adequate for some clinical usages. Conclusion: According to both clinical evaluation (human expert

  16. Risk Factors, Pathobiomechanics and Physical Examination of Rotator Cuff Tears

    PubMed Central

    Moulton, Samuel G.; Greenspoon, Joshua A.; Millett, Peter J.; Petri, Maximilian

    2016-01-01

    Background: It is important to appreciate the risk factors for the development of rotator cuff tears and specific physical examination maneuvers. Methods: A selective literature search was performed. Results: Numerous well-designed studies have demonstrated that common risk factors include age, occupation, and anatomic considerations such as the critical shoulder angle. Recently, research has also reported a genetic component as well. The rotator cuff axially compresses the humeral head in the glenohumeral joint and provides rotational motion and abduction. Forces are grouped into coronal and axial force couples. Rotator cuff tears are thought to occur when the force couples become imbalanced. Conclusion: Physical examination is essential to determining whether a patient has an anterosuperior or posterosuperior tear. Diagnostic accuracy increases when combining a series of examination maneuvers. PMID:27708731

  17. Ultrasound-guided block of sciatic and femoral nerves: an anatomical study.

    PubMed

    Waag, Sonja; Stoffel, Michael H; Spadavecchia, Claudia; Eichenberger, Urs; Rohrbach, Helene

    2014-04-01

    The sheep is a popular animal model for human biomechanical research involving invasive surgery on the hind limb. These painful procedures can only be ethically justified with the application of adequate analgesia protocols. Regional anaesthesia as an adjunct to general anaesthesia may markedly improve well-being of these experimental animals during the postoperative period due to a higher analgesic efficacy when compared with systemic drugs, and may therefore reduce stress and consequently the severity of such studies. As a first step 14 sheep cadavers were used to establish a new technique for the peripheral blockade of the sciatic and the femoral nerves under sonographic guidance and to evaluate the success rate by determination of the colorization of both nerves after an injection of 0.5 mL of a 0.1% methylene blue solution. First, both nerves were visualized sonographically. Then, methylene blue solution was injected and subsequently the length of colorization was measured by gross anatomical dissection of the target nerves. Twenty-four sciatic nerves were identified sonographically in 12 out of 13 cadavers. In one animal, the nerve could not be ascertained unequivocally and, consequently, nerve colorization failed. Twenty femoral nerves were located by ultrasound in 10 out of 13 cadavers. In three cadavers, signs of autolysis impeded the scan. This study provides a detailed anatomical description of the localization of the sciatic and the femoral nerves and presents an effective and safe yet simple and rapid technique for performing peripheral nerve blocks with a high success rate.

  18. Strength of suture anchor versus transosseous tunnel in anatomic reconstruction of the ankle lateral ligaments: a biomechanical study.

    PubMed

    Li, Hong-Yun; Hua, Ying-Hui; Wu, Zi-Ying; Chen, Bo; Chen, Shi-Yi

    2013-11-01

    The purpose of this study was to compare the biomechanical characteristics of fixation with 2-suture anchors versus transosseous tunnel fixation in anatomic reconstruction of the ankle lateral ligaments. Six matched pairs of human cadaveric ankles underwent anatomic lateral ankle reconstruction, and fixation of the graft on the talus was achieved with 2 suture anchors or a transosseous tunnel. Ankles for the transosseous tunnel group were chosen at random, with the paired contralateral ankles used for the 2-suture anchor group. Half of the peroneus brevis tendon was harvested as a graft. For each technique, one end of the tendon was secured to the original insertion point of the anterior talofibular ligament (ATFL) at the talus, whereas the other end was armed with 2 No. 5 nonabsorbable sutures (Ethicon, Somerville, NJ) and passed through the bone tunnel in the fibula. Biomechanical testing was performed by applying the force in line with the graft. Load to failure was determined at a displacement rate of 50 mm/min. The load-displacement curve, maximum load at failure (N), and stiffness (N/mm) were recorded and compared between the 2 techniques. There was no difference between constructs in the 2-suture anchor group and the transosseous tunnel group in terms of the ultimate load and stiffness (161.8 ± 47.6 N v 171.9 ± 76.0 N; P = .92; 4.59 ± 1.85 N/mm v 5.77 ± 1.98 N/mm; P = .35). Most constructs failed because of anchor pullout in the 2-suture anchor group (5 of 6) and fracture of the bony bridge in the transosseous tunnel group (6 of 6). The strength of fixation with suture anchors in anatomic reconstruction of the ankle lateral ligaments was equivalent to transosseous tunnel fixation as determined with biomechanical testing. However, this study did not prove that one is advantageous over the other. Both techniques showed excellent biomechanical results. Therefore, the 2-suture anchor fixation approach can be safely used in anatomic reconstruction of the

  19. Anatomical Variation of the Tarsus in Common Inbred Mouse Strains.

    PubMed

    Richbourg, Heather A; Martin, Matthew J; Schachner, Emma R; McNulty, Margaret A

    2017-03-01

    Rodent models are used for a variety of orthopedic research applications; however, anatomy references include mostly artistic representations. Advanced imaging techniques, including micro-computed tomography (microCT), can provide more accurate representations of subtle anatomical characteristics. A recent microCT atlas of laboratory mouse (Mus musculus) anatomy depicts the central and tarsal bone III (T3) as a single bone, differing from previous references. Fusion of tarsal bones is generally characterized as pathological secondary to mutations associated with growth factors, and normal variation has not been documented in the mouse tarsus. Therefore, it is unclear if this fusion is a normal or a pathological characteristic. The aim of this study is to characterize the tarsus of the laboratory mouse and compare it to the rat and selected outgroup species (i.e., white-footed mouse) via microCT and histology to determine if the central and T3 are separate or fused into a single bone. Laboratory mice (C57/Bl6 [n = 17] and BalbC [n = 2]) and rats (n = 5) were scanned with microCT. A representative laboratory mouse from each strain was evaluated histologically via serial sagittal sections through the mid-tarsus. General pedal anatomy was similar between all species; however, the central and T3 bones were fused in all laboratory mice but not the rat or white-footed mouse. A band of hyaline cartilage was identified within the fused bone of the laboratory mice. We conclude that the fusion found is a normal characteristic in laboratory mice, but timing of the fusion remains ambiguous. Anat Rec, 300:450-459, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  20. The semantic anatomical network: Evidence from healthy and brain-damaged patient populations.

    PubMed

    Fang, Yuxing; Han, Zaizhu; Zhong, Suyu; Gong, Gaolang; Song, Luping; Liu, Fangsong; Huang, Ruiwang; Du, Xiaoxia; Sun, Rong; Wang, Qiang; He, Yong; Bi, Yanchao

    2015-09-01

    Semantic processing is central to cognition and is supported by widely distributed gray matter (GM) regions and white matter (WM) tracts. The exact manner in which GM regions are anatomically connected to process semantics remains unknown. We mapped the semantic anatomical network (connectome) by conducting diffusion imaging tractography in 48 healthy participants across 90 GM "nodes," and correlating the integrity of each obtained WM edge and semantic performance across 80 brain-damaged patients. Fifty-three WM edges were obtained whose lower integrity associated with semantic deficits and together with their linked GM nodes constitute a semantic WM network. Graph analyses of this network revealed three structurally segregated modules that point to distinct semantic processing components and identified network hubs and connectors that are central in the communication across the subnetworks. Together, our results provide an anatomical framework of human semantic network, advancing the understanding of the structural substrates supporting semantic processing. © 2015 Wiley Periodicals, Inc.

  1. Three-Dimensional Anatomic Evaluation of the Anterior Cruciate Ligament for Planning Reconstruction

    PubMed Central

    Hoshino, Yuichi; Kim, Donghwi; Fu, Freddie H.

    2012-01-01

    Anatomic study related to the anterior cruciate ligament (ACL) reconstruction surgery has been developed in accordance with the progress of imaging technology. Advances in imaging techniques, especially the move from two-dimensional (2D) to three-dimensional (3D) image analysis, substantially contribute to anatomic understanding and its application to advanced ACL reconstruction surgery. This paper introduces previous research about image analysis of the ACL anatomy and its application to ACL reconstruction surgery. Crucial bony landmarks for the accurate placement of the ACL graft can be identified by 3D imaging technique. Additionally, 3D-CT analysis of the ACL insertion site anatomy provides better and more consistent evaluation than conventional “clock-face” reference and roentgenologic quadrant method. Since the human anatomy has a complex three-dimensional structure, further anatomic research using three-dimensional imaging analysis and its clinical application by navigation system or other technologies is warranted for the improvement of the ACL reconstruction. PMID:22567310

  2. Radio-guided sentinel lymph node identification by lymphoscintigraphy fused with an anatomical vector profile: clinical applications.

    PubMed

    Niccoli Asabella, A; Antonica, F; Renna, M A; Rubini, D; Notaristefano, A; Nicoletti, A; Rubini, G

    2013-12-01

    To develop a method to fuse lymphoscintigraphic images with an adaptable anatomical vector profile and to evaluate its role in the clinical practice. We used Adobe Illustrator CS6 to create different vector profiles, we fused those profiles, using Adobe Photoshop CS6, with lymphoscintigraphic images of the patient. We processed 197 lymphoscintigraphies performed in patients with cutaneous melanomas, breast cancer or delayed lymph drainage. Our models can be adapted to every patient attitude or position and contain different levels of anatomical details ranging from external body profiles to the internal anatomical structures like bones, muscles, vessels, and lymph nodes. If needed, more new anatomical details can be added and embedded in the profile without redrawing them, saving a lot of time. Details can also be easily hidden, allowing the physician to view only relevant information and structures. Fusion times are about 85 s. The diagnostic confidence of the observers increased significantly. The validation process showed a slight shift (mean 4.9 mm). We have created a new, practical, inexpensive digital technique based on commercial software for fusing lymphoscintigraphic images with built-in anatomical reference profiles. It is easily reproducible and does not alter the original scintigraphic image. Our method allows a more meaningful interpretation of lymphoscintigraphies, an easier recognition of the anatomical site and better lymph node dissection planning.

  3. Principal component analysis-based anatomical motion models for use in adaptive radiation therapy of head and neck cancer patients

    NASA Astrophysics Data System (ADS)

    Chetvertkov, Mikhail A.

    the higher dose volumes during the radiotherapy course. Modeled DVHs still underestimated the effect of parotid shrinkage due to the large compression factor (CF) used to acquire DVFs. Conclusion: Leading EDVFs from both PCA approaches have the potential to capture systematic anatomical changes during H&N radiotherapy when systematic changes are large enough with respect to random fraction-to-fraction changes. In all cases the RPCA approach appears to be more reliable than SPCA at capturing systematic changes, enabling dosimetric consequences to be projected to the future treatment fractions based on trends established early in a treatment course, or, potentially, based on population models. This work showed that PCA has a potential in identifying the major mode of anatomical changes during the radiotherapy course and subsequent use of this information in future dose predictions is feasible. Use of smaller CF values for DVFs is preferred, otherwise anatomical motion will be underestimated.

  4. Three-dimensional study of pelvic asymmetry on anatomical specimens and its clinical perspectives.

    PubMed

    Boulay, Christophe; Tardieu, Christine; Bénaim, Charles; Hecquet, Jérome; Marty, Catherine; Prat-Pradal, Dominique; Legaye, Jean; Duval-Beaupère, Ginette; Pélissier, Jacques

    2006-01-01

    The aim of this study was to assess pelvic asymmetry (i.e. to determine whether the right iliac bone and the right part of the sacrum are mirror images of the left), both quantitatively and qualitatively, using three-dimensional measurements. Pelvic symmetry was described osteologically using a common reference coordinate system for a large sample of pelvises. Landmarks were established on 12 anatomical specimens with an electromagnetic Fastrak system. Seventy-one paired variables were tested with a paired t-test and a non-parametric test (Wilcoxon). A Pearson correlation matrix between the right and left values of the same variable was applied exclusively to values that were significantly asymmetric in order to calculate a dimensionless asymmetry index, ABGi, for each variable. Fifteen variables were significantly asymmetric and correlated with the right vs. left sides for the following anatomical regions: sacrum, iliac blades, iliac width, acetabulum and the superior lunate surface of the acetabulum. ABGi values above a threshold of +/- 4.8% were considered significantly asymmetric in seven variables of the pelvic area. Total asymmetry involving the right and the left pelvis seems to follow a spiral path in the pelvis; in the upper part, the iliac blades rotate clockwise, and in the lower part, the pubic symphysis rotates anticlockwise. Thus, pelvic asymmetry may be evaluated in clinical examinations by measuring iliac crest orientation.

  5. Three-dimensional study of pelvic asymmetry on anatomical specimens and its clinical perspectives

    PubMed Central

    Boulay, Christophe; Tardieu, Christine; Bénaim, Charles; Hecquet, Jérome; Marty, Catherine; Prat-Pradal, Dominique; Legaye, Jean; Duval-Beaupère, Ginette; Pélissier, Jacques

    2006-01-01

    The aim of this study was to assess pelvic asymmetry (i.e. to determine whether the right iliac bone and the right part of the sacrum are mirror images of the left), both quantitatively and qualitatively, using three-dimensional measurements. Pelvic symmetry was described osteologically using a common reference coordinate system for a large sample of pelvises. Landmarks were established on 12 anatomical specimens with an electromagnetic Fastrak system. Seventy-one paired variables were tested with a paired t-test and a non-parametric test (Wilcoxon). A Pearson correlation matrix between the right and left values of the same variable was applied exclusively to values that were significantly asymmetric in order to calculate a dimensionless asymmetry index, ABGi, for each variable. Fifteen variables were significantly asymmetric and correlated with the right vs. left sides for the following anatomical regions: sacrum, iliac blades, iliac width, acetabulum and the superior lunate surface of the acetabulum. ABGi values above a threshold of ± 4.8% were considered significantly asymmetric in seven variables of the pelvic area. Total asymmetry involving the right and the left pelvis seems to follow a spiral path in the pelvis; in the upper part, the iliac blades rotate clockwise, and in the lower part, the pubic symphysis rotates anticlockwise. Thus, pelvic asymmetry may be evaluated in clinical examinations by measuring iliac crest orientation. PMID:16420376

  6. Urinary obstruction is an important complicating factor in patients with septic shock due to urinary infection.

    PubMed

    Reyner, Karina; Heffner, Alan C; Karvetski, Colleen H

    2016-04-01

    Urinary tract infection (UTI) is a common cause of severe sepsis, and anatomic urologic obstruction is a recognized factor for complicated disease. We aimed to identify the incidence of urinary obstruction complicating acute septic shock and determine the characteristics and outcomes of this group. Patients prospectively enrolled in a sepsis treatment pathway registry between October 2013 and July 2014 were reviewed for the diagnosis of UTI. Standardized medical record review was performed to confirm sepsis due to UTI and determine clinical variables including the presence of anatomic urinary obstruction. Patients with septic shock due to UTI with obstruction were compared with those without obstruction. The primary outcomes were incidence of urinary obstruction and hospital mortality. Among 1084 registry enrollees, 209 (19.2%) met inclusion criteria for the study. Acute anatomic obstruction was identified in 22 (10.5%) patients. Hospital mortality in patients with obstruction was 27.3% compared with 11.2% in patients without obstruction (absolute difference of 16.1%; P = .03; 95% confidence interval [CI], 1.2%-30.9%). Hospital length of stay among survivors was 12.8 days compared with 8.3 days (absolute difference of 4.5 days; P = .04; 95% CI, 0.2-8.8 days). History of urinary stone disease was independently associated with obstruction (odds ratio, 5.6; 95% CI, 2.2-14.3). Approximately 1 in 10 patients presenting with septic shock due to a urinary source is complicated by anatomic urinary obstruction. These patients have significantly higher mortality compared with patients without obstruction. Early imaging of patients with septic shock due to suspected urinary source should be considered to identify obstruction requiring emergency intervention. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. Influence of cervical preflaring on apical file size determination.

    PubMed

    Pecora, J D; Capelli, A; Guerisoli, D M Z; Spanó, J C E; Estrela, C

    2005-07-01

    instrument binding technique for determining anatomical diameter at WL is not precise. Preflaring of the cervical and middle thirds of the root canal improved anatomical diameter determination; the instrument used for preflaring played a major role in determining the anatomical diameter at the WL. Canals preflared with LA Axxess burs created a more accurate relationship between file size and anatomical diameter.

  8. Preliminary Study on Appearance-Based Detection of Anatomical Point Landmarks in Body Trunk CT Images

    NASA Astrophysics Data System (ADS)

    Nemoto, Mitsutaka; Nomura, Yukihiro; Hanaoka, Shohei; Masutani, Yoshitaka; Yoshikawa, Takeharu; Hayashi, Naoto; Yoshioka, Naoki; Ohtomo, Kuni

    Anatomical point landmarks as most primitive anatomical knowledge are useful for medical image understanding. In this study, we propose a detection method for anatomical point landmark based on appearance models, which include gray-level statistical variations at point landmarks and their surrounding area. The models are built based on results of Principal Component Analysis (PCA) of sample data sets. In addition, we employed generative learning method by transforming ROI of sample data. In this study, we evaluated our method with 24 data sets of body trunk CT images and obtained 95.8 ± 7.3 % of the average sensitivity in 28 landmarks.

  9. DETERMINATION OF RELATIVE IMPORTANCE OF NONPROLIFERATION FACTORS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Richard Metcalf

    2009-07-01

    Methodologies to determine the proliferation resistance (PR) of nuclear facilities often rely on either expert elicitation, a resource-intensive approach without easily reproducible results, or numeric evaluations, which can fail to take into account the institutional knowledge and expert experience of the nonproliferation community. In an attempt to bridge the gap and bring the institutional knowledge into numeric evaluations of PR, a survey was conducted of 33 individuals to find the relative importance of a set of 62 nonproliferation factors, subsectioned into groups under the headings of Diversion, Transportation, Transformation, and Weaponization. One third of the respondents were self-described nonproliferation professionals,more » and the remaining two thirds were from secondary professions related to nonproliferation, such as industrial engineers or policy analysts. The factors were taken from previous work which used multi-attribute utility analysis with uniform weighting of attributes and did not include institutional knowledge. In both expert and non-expert groups, all four headings and the majority of factors had different relative importance at a confidence of 95% (p=0.05). This analysis and survey demonstrates that institutional knowledge can be brought into numeric evaluations of PR, if there is a sufficient investment of resources made prior to the evaluation.« less

  10. Anatomic Basis for Penis Transplantation: Cadaveric Microdissection of Penile Structures.

    PubMed

    Tiftikcioglu, Yigit Ozer; Erenoglu, Cagil Meric; Lineaweaver, William C; Bilge, Okan; Celik, Servet; Ozek, Cuneyt

    2016-06-01

    We present a cadaveric dissection study to investigate the anatomic feasibility of penile transplantation. Seventeen male cadavers were dissected to reveal detailed anatomy of the dorsal neurovascular structures including dorsal arteries, superficial and deep dorsal veins, and dorsal nerves of the penis. Dorsal artery diameters showed a significant decrease from proximal to distal shaft. Dominance was observed in one side. Deep dorsal vein showed a straight course and less decrease in diameter compared to artery. Dorsal nerves showed proximal branching pattern. In a possible penile transplantation, level of harvest should be determined according to the patient and the defect, where a transgender patient will receive a total allograft and a male patient with a proximal penile defect will receive a partial shaft allograft. We designed an algorithm for different levels of penile defect and described the technique for harvest of partial and total penile transplants.

  11. Anatomic and functional properties of bulboglandularis striated muscle support its contribution as sphincter in female rabbit micturition.

    PubMed

    Corona-Quintanilla, Dora Luz; López-Juárez, Rhode; Zempoalteca, René; Cuevas, Estela; Castelán, Francisco; Martínez-Gómez, Margarita

    2016-08-01

    To determine anatomic and functional properties of the bulboglandularis muscle (Bgm) for clarifying its role in micturition in female rabbits. Virgin female rabbits were used to describe the gross anatomy and innervation of the Bgm, to determine the effect of the Bgm contraction on urethral pressure, and to evaluate the Bgm activity during the induced-micturition. Both electromyogram and cystometrogram activity were simultaneously recorded in urethane-anesthetized rabbits. Bladder function was assessed measuring standard urodynamic variables before and after blocking the Bgm activity for approaching its contribution to micturition. The relevance of the Bgm activation for micturition was approached applying lidocaine injections. The Bgm was composed of circularly oriented striated fibers enveloping distal urethra and pelvic vagina. Both the venous plexus and urethra were comprised by the Bgm contraction induced by electrical stimulation. The Bgm showed bursts of tonic activity at the storage phase of micturition that gradually decreased until turning off as the onset of the voiding phase. The voided volume, the voiding efficiency, the threshold pressure, and the maximal pressure were decreased after lidocaine injection. Contrastingly, the threshold volume, the residual volume, the voiding duration, and the urethral resistance at voiding were increased. Present anatomical and physiological findings support that the Bgm acts as a sphincter during micturition of female rabbits. Neurourol. Urodynam. 35:689-695, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  12. [Sacroiliac joint injury treated with oblique insertion at anatomical points: a randomized controlled trial].

    PubMed

    Kuang, Jiayi; Li, Yuxuan; He, Yufeng; Gan, Lin; Wang, Aiming; Chen, Yanhua; Li, Xiaoting; Guo, Lin; Tang, Rongjun

    2016-04-01

    To compare the effects of oblique insertion at anatomical points and conventional acupuncture for sacroiliac joint injury. Eighty patients were randomly divided into an observation group and a control group, 40 cases in each one. In the observation group, oblique insertion therapy at anatomical points was used, and the 9 points of equal division (anatomical points) marked by palpating the anatomical symbol were treated as the insertion acupoints. In the control group, conventional acupuncture was applied, and perpendicular insertion was adopted at Huantiao (GB 30), Zhibian (BL 54) and Weizhong (BL 40), etc. In the two groups, the! treatment was given once a day and 5 times per week. Ten treatments were made into one course and two courses were required. The clinical effects, the changes of visual analogue scale (VAS) and Oswestry dysfunctional index. (ODI) before and after treatment were observed in the two groups. The total effective rate of the observation group was 90.0% (36/40), which was better than 72.5% (29/40) of the control group (P < 0.05). After treatment, the results of the VAS and ODI of the two groups were apparently declined (both P < 0.01), and those in the observation group were decreased more obviously (both P < 0.01). The effect of oblique inser-tion at anatomical points for sacroiliac joint injury is superior to that of conventional acupuncture, which can effectively relieve pain and improve the disfunction.

  13. Automated anatomical description of pleural thickening towards improvement of its computer-assisted diagnosis

    NASA Astrophysics Data System (ADS)

    Chaisaowong, Kraisorn; Jiang, Mingze; Faltin, Peter; Merhof, Dorit; Eisenhawer, Christian; Gube, Monika; Kraus, Thomas

    2016-03-01

    Pleural thickenings are caused by asbestos exposure and may evolve into malignant pleural mesothelioma. An early diagnosis plays a key role towards an early treatment and an increased survival rate. Today, pleural thickenings are detected by visual inspection of CT data, which is time-consuming and underlies the physician's subjective judgment. A computer-assisted diagnosis system to automatically assess pleural thickenings has been developed, which includes not only a quantitative assessment with respect to size and location, but also enhances this information with an anatomical description, i.e. lung side (left, right), part of pleura (pars costalis, mediastinalis, diaphragmatica, spinalis), as well as vertical (upper, middle, lower) and horizontal (ventral, dorsal) position. For this purpose, a 3D anatomical model of the lung surface has been manually constructed as a 3D atlas. Three registration sub-steps including rigid, affine, and nonrigid registration align the input patient lung to the 3D anatomical atlas model of the lung surface. Finally, each detected pleural thickening is assigned a set of labels describing its anatomical properties. Through this added information, an enhancement to the existing computer-assisted diagnosis system is presented in order to assure a higher precision and reproducible assessment of pleural thickenings, aiming at the diagnosis of the pleural mesothelioma in its early stage.

  14. Data-Driven Sequence of Changes to Anatomical Brain Connectivity in Sporadic Alzheimer's Disease.

    PubMed

    Oxtoby, Neil P; Garbarino, Sara; Firth, Nicholas C; Warren, Jason D; Schott, Jonathan M; Alexander, Daniel C

    2017-01-01

    Model-based investigations of transneuronal spreading mechanisms in neurodegenerative diseases relate the pattern of pathology severity to the brain's connectivity matrix, which reveals information about how pathology propagates through the connectivity network. Such network models typically use networks based on functional or structural connectivity in young and healthy individuals, and only end-stage patterns of pathology, thereby ignoring/excluding the effects of normal aging and disease progression. Here, we examine the sequence of changes in the elderly brain's anatomical connectivity over the course of a neurodegenerative disease. We do this in a data-driven manner that is not dependent upon clinical disease stage, by using event-based disease progression modeling. Using data from the Alzheimer's Disease Neuroimaging Initiative dataset, we sequence the progressive decline of anatomical connectivity, as quantified by graph-theory metrics, in the Alzheimer's disease brain. Ours is the first single model to contribute to understanding all three of the nature, the location, and the sequence of changes to anatomical connectivity in the human brain due to Alzheimer's disease. Our experimental results reveal new insights into Alzheimer's disease: that degeneration of anatomical connectivity in the brain may be a viable, even early, biomarker and should be considered when studying such neurodegenerative diseases.

  15. CT Morphometric Analysis to Determine the Anatomical Basis for the Use of Transpedicular Screws during Reconstruction and Fixations of Anterior Cervical Vertebrae

    PubMed Central

    Chen, Chun; Ruan, Dike; Wu, Changfu; Wu, Weidong; Sun, Peidong; Zhang, Yuanzhi; Wu, Jigong; Lu, Sheng; Ouyang, Jun

    2013-01-01

    Background Accurate placement of pedicle screw during Anterior Transpedicular Screw fixation (ATPS) in cervical spine depends on accurate anatomical knowledge of the vertebrae. However, little is known of the morphometric characteristics of cervical vertebrae in Chinese population. Methods Three-dimensional reconstructions of CT images were performed for 80 cases. The anatomic data and screw fixation parameters for ATPS fixation were measured using the Mimics software. Findings The overall mean OPW, OPH and PAL ranged from 5.81 to 7.49 mm, 7.77 to 8.69 mm, and 33.40 to 31.13 mm separately, and SPA was 93.54 to 109.36 degrees from C3 to C6, 104.99 degrees at C7, whereas, 49.00 to 32.26 degrees from C4 to C7, 46.79 degrees at C3 (TPA). Dl/rSIP had an increasing trend away from upper endplate with mean value from 1.87 to 5.83 mm. Dl/rTIP was located at the lateral portion of the anterior cortex of vertebrae for C3 to C5 and ipsilateral for C6 to C7 with mean value from −2.70 to −3.00 mm, and 0.17 to 3.18 mm. The entrance points for pedicular screw insertion for C3 to C5 and C6 to C7 were recommended −2∼−3 mm and 0–4 mm from the median sagittal plane, respectively, 1–4 mm and 5–6 mm from the upper endplate, with TPA being 46.79–49.00 degrees and 40.89–32.26 degrees, respectively, and SPA being 93.54–106.69 degrees and 109.36–104.99 degrees, respectively. The pedicle screw insertion diameter was recommended 3.5 mm (C3 and C4), 4.0 mm (C5 to C7), and the pedicle axial length was 21–24 mm for C3 to C7 for both genders. However, the ATPS insertion in C3 should be individualized given its relatively small anatomical dimensions. Conclusions The data provided a morphometric basis for the ATPS fixation technique in lower cervical fixation. It will help in preoperative planning and execution of this surgery. PMID:24349038

  16. Patient's Height and Hip Medial Offset Are the Main Determinants of the Valgus Cut Angle During Total Knee Arthroplasty.

    PubMed

    Drexler, Michael; Abolghasemian, Mansour; Barbuto, Richard; Naini, Mohsen S; Voshmeh, Neda; Rutenberg, Tal F; Schwarzkopf, Ran; Backstein, David J

    2017-05-01

    Valgus cut angle (VCA), defined as the angle between the anatomical and the mechanical axes of femur, is an important parameter upon which a critical step of knee arthroplasty is based. Some variables have been proposed to affect the magnitude of this cut. However, little information is available regarding whether a generic value can be used, or if a patient-specific value from a long leg X-ray, or factors that can be determined preoperatively, is necessary to accurately set the VCA. Standard standing 3-joint views were used to measure a number of anatomical measurements in 358 limbs, 202 patients (116 women, 86 men). Neck-shaft angle, medial offset, femoral length (FL), distal femoral articular angle, and VCA were measured. Demographic data including gender and height were extracted from hospital charts. The correlation of VCA with each of the other factors was evaluated using linear regression and t-test and finally multivariate analysis. The average VCA was 5.76° (range 4-8). Gender and distal femoral articular angle were not related to VCA (P = .343 and .995). FL was found to be a function of height with similar effects on multivariate analysis. Only the height (or FL) and femoral offset were identified as independent factors, with a negative correlation for the former (P < .001) and a positive correlation for the latter (P < .001). Femoral offset and height are the 2 independent factors determining VCA. Other parameters are indirectly related to these 2 factors. Tall patients with a small femoral offset have smaller VCA and short patients with a large offset have larger VCA. The wide variety of VCA values does not support using a generic value for all patients during knee arthroplasty. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Anatomical background and generalized detectability in tomosynthesis and cone-beam CT.

    PubMed

    Gang, G J; Tward, D J; Lee, J; Siewerdsen, J H

    2010-05-01

    Anatomical background presents a major impediment to detectability in 2D radiography as well as 3D tomosynthesis and cone-beam CT (CBCT). This article incorporates theoretical and experimental analysis of anatomical background "noise" in cascaded systems analysis of 2D and 3D imaging performance to yield "generalized" metrics of noise-equivalent quanta (NEQ) and detectability index as a function of the orbital extent of the (circular arc) source-detector orbit. A physical phantom was designed based on principles of fractal self-similarity to exhibit power-law spectral density (kappa/Fbeta) comparable to various anatomical sites (e.g., breast and lung). Background power spectra [S(B)(F)] were computed as a function of source-detector orbital extent, including tomosynthesis (approximately 10 degrees -180 degrees) and CBCT (180 degrees + fan to 360 degrees) under two acquisition schemes: (1) Constant angular separation between projections (variable dose) and (2) constant total number of projections (constant dose). The resulting S(B) was incorporated in the generalized NEQ, and detectability index was computed from 3D cascaded systems analysis for a variety of imaging tasks. The phantom yielded power-law spectra within the expected spatial frequency range, quantifying the dependence of clutter magnitude (kappa) and correlation (beta) with increasing tomosynthesis angle. Incorporation of S(B) in the 3D NEQ provided a useful framework for analyzing the tradeoffs among anatomical, quantum, and electronic noise with dose and orbital extent. Distinct implications are posed for breast and chest tomosynthesis imaging system design-applications varying significantly in kappa and beta, and imaging task and, therefore, in optimal selection of orbital extent, number of projections, and dose. For example, low-frequency tasks (e.g., soft-tissue masses or nodules) tend to benefit from larger orbital extent and more fully 3D tomographic imaging, whereas high-frequency tasks (e

  18. Insights into the Freiburg Anatomical Institute during National Socialism, 1933-1945.

    PubMed

    Hildebrandt, Sabine

    2016-05-01

    The Anatomical Institute at the Albert-Ludwigs-Universität Freiburg is among the anatomical departments for which a comprehensive account of its history during National Socialism (NS) is still missing. Previous investigations (such as in: Grün et al., 2002) have revealed the political activities of some anatomists, but, in the absence of relevant body-registers, a more comprehensive examination of the anatomical body procurement has not been attempted. The inspection of records in university and municipal archives allows insight into the activities in the institute within the historical context. The Freiburg Institute shared the experience of the impact of NS politics with other German anatomies. Four anatomists were dismissed because of NS racial discrimination, and chairman von Möllendorf left for political reasons. His successor Nauck's appointment was politically motivated, as he was a staunch Nazi. His colleagues were also members of NS political organizations. Body procurement was controversial between the public and the anatomists in Freiburg prior to and following the Third Reich, and much of the anatomists' efforts focused on the improvement of the body supply. In 1935, and, again during the war, the number of bodies was sufficient for anatomical education. Among the traditional sources of body procurement were increasing numbers of NS victims. Forty-four of them can be identified, among them 21 forced laborers and their children who died of so-called natural causes, and 22 men who had been executed at Stuttgart prison on April 6, 1943. While the victims' names have been ascertained, their biographies still need restoration to ensure an appropriate commemoration. Copyright © 2016 Elsevier GmbH. All rights reserved.

  19. CAVEman: Standardized Anatomical Context for Biomedical Data Mapping

    ERIC Educational Resources Information Center

    Turinsky, Andrei L.; Fanea, Elena; Trinh, Quang; Wat, Stephen; Hallgrimsson, Benedikt; Dong, Xiaoli; Shu, Xueling; Stromer, Julie N.; Hill, Jonathan W.; Edwards, Carol; Grosenick, Brenda; Yajima, Masumi; Sensen, Christoph W.

    2008-01-01

    The authors have created a software system called the CAVEman, for the visual integration and exploration of heterogeneous anatomical and biomedical data. The CAVEman can be applied for both education and research tasks. The main component of the system is a three-dimensional digital atlas of the adult male human anatomy, structured according to…

  20. 42 CFR 402.208 - Factors considered in determining whether to exclude, and the length of exclusion.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 2 2010-10-01 2010-10-01 false Factors considered in determining whether to..., ASSESSMENTS, AND EXCLUSIONS Exclusions § 402.208 Factors considered in determining whether to exclude, and the length of exclusion. (a) General factors. In determining whether to exclude a person and the length of...

  1. Simultaneous anatomical sketching as learning by doing method of teaching human anatomy.

    PubMed

    Noorafshan, Ali; Hoseini, Leila; Amini, Mitra; Dehghani, Mohammad-Reza; Kojuri, Javad; Bazrafkan, Leila

    2014-01-01

    Learning by lecture is a passive experience. Many innovative techniques have been presented to stimulate students to assume a more active attitude toward learning. In this study, simultaneous sketch drawing, as an interactive learning technique was applied to teach anatomy to the medical students. We reconstructed a fun interactive model of teaching anatomy as simultaneous anatomic sketching. To test the model's instruction effectiveness, we conducted a quasi- experimental study and then the students were asked to write their learning experiences in their portfolio, also their view was evaluated by a questionnaire. The results of portfolio evaluation revealed that students believed that this method leads to deep learning and understanding anatomical subjects better. Evaluation of the students' views on this teaching approach was showed that, more than 80% of the students were agreed or completely agreed with this statement that leaning anatomy concepts are easier and the class is less boring with this method. More than 60% of the students were agreed or completely agreed to sketch anatomical figures with professor simultaneously. They also found the sketching make anatomy more attractive and it reduced the time for learning anatomy. These number of students were agree or completely agree that the method help them learning anatomical concept in anatomy laboratory. More than 80% of the students found the simultaneous sketching is a good method for learning anatomy overall. Sketch drawing, as an interactive learning technique, is an attractive for students to learn anatomy.

  2. The new vestibular stimuli: sound and vibration-anatomical, physiological and clinical evidence.

    PubMed

    Curthoys, Ian S

    2017-04-01

    The classical view of the otoliths-as flat plates of fairly uniform receptors activated by linear acceleration dragging on otoconia and so deflecting the receptor hair bundles-has been replaced by new anatomical and physiological evidence which shows that the maculae are much more complex. There is anatomical spatial differentiation across the macula in terms of receptor types, hair bundle heights, stiffness and attachment to the overlying otolithic membrane. This anatomical spatial differentiation corresponds to the neural spatial differentiation of response dynamics from the receptors and afferents from different regions of the otolithic maculae. Specifically, receptors in a specialized band of cells, the striola, are predominantly type I receptors, with short, stiff hair bundles and looser attachment to the overlying otoconial membrane than extrastriolar receptors. At the striola the hair bundles project into holes in the otolithic membrane, allowing for fluid displacement to deflect the hair bundles and activate the cell. This review shows the anatomical and physiological evidence supporting the hypothesis that fluid displacement, generated by sound or vibration, deflects the short stiff hair bundles of type I receptors at the striola, resulting in neural activation of the irregular afferents innervating them. So these afferents are activated by sound or vibration and show phase-locking to individual cycles of the sound or vibration stimulus up to frequencies above 2000 Hz, underpinning the use of sound and vibration for clinical tests of vestibular function.

  3. Anatomical modeling of the bronchial tree

    NASA Astrophysics Data System (ADS)

    Hentschel, Gerrit; Klinder, Tobias; Blaffert, Thomas; Bülow, Thomas; Wiemker, Rafael; Lorenz, Cristian

    2010-02-01

    The bronchial tree is of direct clinical importance in the context of respective diseases, such as chronic obstructive pulmonary disease (COPD). It furthermore constitutes a reference structure for object localization in the lungs and it finally provides access to lung tissue in, e.g., bronchoscope based procedures for diagnosis and therapy. This paper presents a comprehensive anatomical model for the bronchial tree, including statistics of position, relative and absolute orientation, length, and radius of 34 bronchial segments, going beyond previously published results. The model has been built from 16 manually annotated CT scans, covering several branching variants. The model is represented as a centerline/tree structure but can also be converted in a surface representation. Possible model applications are either to anatomically label extracted bronchial trees or to improve the tree extraction itself by identifying missing segments or sub-trees, e.g., if located beyond a bronchial stenosis. Bronchial tree labeling is achieved using a naïve Bayesian classifier based on the segment properties contained in the model in combination with tree matching. The tree matching step makes use of branching variations covered by the model. An evaluation of the model has been performed in a leaveone- out manner. In total, 87% of the branches resulting from preceding airway tree segmentation could be correctly labeled. The individualized model enables the detection of missing branches, allowing a targeted search, e.g., a local rerun of the tree-segmentation segmentation.

  4. [Application of polyguanidine solution for fixation of biological and anatomical specimens].

    PubMed

    Anichkov, N M; Danilova, I A; Riabinin, I A; Kipenko, A V

    2010-01-01

    A new method for fixation of biological material is described, and its effectiveness is compared to that one of formalin fixation. As an embalming agent, polyhexamethylenguanidine (PHMG) hydrochloride was used. Using the proposed method of fixation, the anatomical and histological preparations of human organs and of chick embryos at developmental 12 days, were produced. The anatomical preparations obtained show the appearance, similar to that of the recently removed organs. Histological preparations were free from significant distortions of the microscopic characteristics of the specimens, which are typical to the material fixed with formalin. The results of the study suggest the possibility of PHMG application in the morphological studies.

  5. Determinate factors of mental health status in Chinese medical staff

    PubMed Central

    Zhou, Chenyu; Shi, Lei; Gao, Lei; Liu, Wenhui; Chen, Zhenkang; Tong, Xinfa; Xu, Wen; Peng, Boshi; Zhao, Yan; Fan, Lihua

    2018-01-01

    Abstract Numerous previous studies have investigated the mental health status of medical staff in China and explored its associated determinate factors; however, scope and methods associated with these have introduced uncertainty regarding the results. The aim of this study was to perform a comprehensive examination of the mental health status of Chinese medical staff and its relative risk factors based on a cross-sectional survey. We conducted a broad area, cross-sectional, questionnaire-based survey of Chinese medical workers. Participants were randomly selected from 27 hospitals in the Heilongjiang province. The questionnaire that was distributed consisted of 5 parts: the demographic characteristics of the participant; questions related to the relative risk factors of psychological health; the posttraumatic stress disorder (PTSD) Checklist-Civilian Version (PCL-C); the Self-rating Depression Scale (SDS); and the Self-rating Anxiety Scale (SAS). The last 3 components were used to evaluate the mental health status of the target population. Logistic and linear regression were used to analyze the determinate factors of the mental health status of Chinese medical staff. Of the 1679 questionnaires distributed, 1557 medical workers responded (response rate: 92.73%; male: 24.1%; female 75.9%). The results of mental health status self-assessments indicated that 32.3% of participants were considered to have some degree of PTSD (based on the PCL-C). The SDS index was 0.67 and the mean score from SAS was 55.26; a result higher than found in the general population. Multivariate logistic regression analysis revealed that being female, dissatisfaction or average satisfaction with income, and good or very good self-perceived psychological endurance when faced with an emergency were associated with a reduction of PTSD symptoms. A frequency of verbal abuse incidents greater than 4 was associated with an increase in PTSD symptoms. The mental health status of Chinese medical staff

  6. Ultrasonographic identification of the anatomical landmarks that define cervical lymph nodes spaces.

    PubMed

    Lenghel, Lavinia Manuela; Baciuţ, Grigore; Botar-Jid, Carolina; Vasilescu, Dan; Bojan, Anca; Dudea, Sorin M

    2013-03-01

    The localization of cervical lymph nodes is extremely important in practice for the positive and differential diagnosis as well as the staging of cervical lymphadenopathies. Ultrasonography represents the first line imaging method in the diagnosis of cervical lymphadenopathies due to its excellent resolution and high diagnosis accuracy. The present paper aims to illustrate the ultrasonographic identification of the anatomical landmarks used for the definition of cervical lymphatic spaces. The application of standardized views allows a delineation of clear anatomical landmarks and an accurate localization of the cervical lymph nodes.

  7. Indexing Anatomical Phrases in Neuro-Radiology Reports to the UMLS 2005AA

    PubMed Central

    Bashyam, Vijayaraghavan; Taira, Ricky K.

    2005-01-01

    This work describes a methodology to index anatomical phrases to the 2005AA release of the Unified Medical Language System (UMLS). A phrase chunking tool based on Natural Language Processing (NLP) was developed to identify semantically coherent phrases within medical reports. Using this phrase chunker, a set of 2,551 unique anatomical phrases was extracted from brain radiology reports. These phrases were mapped to the 2005AA release of the UMLS using a vector space model. Precision for the task of indexing unique phrases was 0.87. PMID:16778995

  8. Integration of the physiological factors determining endurance performance ability.

    PubMed

    Coyle, E F

    1995-01-01

    This model is used to understand the interrelationships of the physiological factors determining endurance performance ability during prolonged exercise. Early studies found that marathon runners maintain a velocity in competition that corresponds to the intensity at which lactate begins to accumulate in blood and muscle [7, 8, 19]. From this observation, the concept developed that this blood lactate threshold (LT Vo2) reflects the degree of muscular stress, glycogenolysis and fatigue. However, it was not clear whether the lactate accumulation was a result of cardiovascular limitations linked to oxygen delivery, as reflected by Vo2max [54], as opposed to metabolic factors in the exercising muscle related to the extent to which mitochondrial respiration is disturbed to maintain a given rate of O2 consumption [29, 30]. Two studies were performed to determine whether LT Vo2 was tightly coupled to Vo2max. In one study, endurance-trained ischemic heart disease patients were observed to possess a Vo2max that was 18% below that of normal master athletes who followed the patient's training program and who displayed the same performance ability as the patients. Both the patients and the normal men displayed an identical LT Vo2 (i.e., 37 ml/kg/min) (Fig. 2.5). Therefore, performance was determined primarily by LT Vo2 instead of Vo2max in this situation, albeit with abnormal subjects. In a second study we assembled two groups of competitive cyclists who were identical in Vo2max but differed by having a high or low LT Vo2 (82% vs. 66% Vo2max) [13]. When cycling at 80-88% Vo2max, the low LT group displayed more than a 2-fold higher rate of muscle glycogen use and blood lactate concentration, and as a result were able to exercise only one-half as long as the high LT group. Performance time for a given Vo2 was clearly related to LT Vo2 instead of Vo2max (Fig. 2.6). This is not to say that Vo2max plays no role in determining LT Vo2, because as in heart disease patients, it clearly

  9. Factors determining satisfaction in psychiatry training in Israel.

    PubMed

    Ellencweig, Natalie; Weizman, Abraham; Fischel, Tsvi

    2009-01-01

    The authors aim to identify the most important factors for Israeli residents in determining their satisfaction with psychiatric training programs and to compare the findings with similar U.S. data. One hundred sixty Israeli psychiatric residents were asked to complete a 40-item questionnaire indicating the relative importance of these items in determining their satisfaction with training on a five-point Likert scale. A total of 100 residents from 15 programs completed the survey. The authors composed a list of the 10 most important items in determining Israeli residents' satisfaction with psychiatric training. "Quality of supervision" and "respect of faculty for residents" were the most important items on this list. These items were ranked significantly higher than all the rest of the items. The authors identified some significant differences between subgroups of the Israeli residents, namely the Israeli and international medical graduates. The list of the most important items for Israeli residents was found to be very similar to published findings for U.S. residents. Program directors should consider this list of most important items in determining resident satisfaction, especially the domains of educational opportunities and educational ambiance, when attempting to improve training programs.

  10. Customer satisfaction in anatomic pathology. A College of American Pathologists Q-Probes study of 3065 physician surveys from 94 laboratories.

    PubMed

    Zarbo, Richard J; Nakhleh, Raouf E; Walsh, Molly

    2003-01-01

    Measurement of physicians' and patients' satisfaction with laboratory services has recently become a requirement of health care accreditation agencies in the United States. To our knowledge, this is the first customer satisfaction survey of anatomic pathology services to provide a standardized tool and benchmarks for subsequent measures of satisfaction. This Q-Probes study assessed physician satisfaction with anatomic pathology laboratory services and sought to determine characteristics that correlate with a high level of physician satisfaction. In January 2001, each laboratory used standardized survey forms to assess physician customer satisfaction with 10 specific elements of service in anatomic pathology and an overall satisfaction rating based on a scale of rankings from a 5 for excellent to a 1 for poor. Data from up to 50 surveys returned per laboratory were compiled and analyzed by the College of American Pathologists. A general questionnaire collected information about types of services offered and each laboratory's quality assurance initiatives to determine characteristics that correlate with a high level of physician satisfaction. Hospital-based laboratories in the United States (95.8%), as well as others from Canada and Australia. Ninety-four voluntary subscriber laboratories in the College of American Pathologists Q-Probes quality improvement program participated in this survey. Roughly 70% of respondents were from hospitals with occupied bedsizes of 300 or less, 65% were private nonprofit institutions, just over half were located in cities, one third were teaching hospitals, and 19% had pathology residency training programs. Overall physician satisfaction with anatomic pathology and 10 selected aspects of the laboratory service (professional interaction, diagnostic accuracy, pathologist responsiveness to problems, pathologist accessibility for frozen section, tumor board presentations, courtesy of secretarial and technical staff, communication of

  11. Anatomical considerations on the discomalleolar ligament

    PubMed Central

    RODRÍGUEZ-VÁZQUEZ, J. F.; MÉRIDA-VELASCO, J. R.; MÉRIDA-VELASCO, J. A.; JIMÉNEZ-COLLADO, J.

    1998-01-01

    A study was carried out on the discomalleolar ligament by dissection of adult human cadavers. The ligament corresponds to the most internal portion of the superior lamina of the temporomandibular joint capsule. It extends from the posterointernal portion of the temporomandibular joint disc, penetrates the petrotympanic fissure and reaches the malleus of the middle ear. Because of its morphology and anatomical arrangement the discomalleolar ligament should be considered as an intrinsic ligament of the temporomandibular joint and distinguished from the tympanic portion of the sphenomandibular ligament (anterior ligament of the malleus). PMID:9723988

  12. 19 CFR 103.23 - Factors in determining whether to disclose information pursuant to a demand.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 19 Customs Duties 1 2010-04-01 2010-04-01 false Factors in determining whether to disclose... Disclosure in Federal, State, Local, and Foreign Proceedings § 103.23 Factors in determining whether to... those demands with respect to which any of the following factors exist: (1) Disclosure would violate a...

  13. TU-AB-303-02: A Novel Surrogate to Identify Anatomical Changes During Radiotherapy of Head and Neck Cancer Patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gros, S; Roeske, J; Surucu, M

    Purpose: To develop a novel method to monitor external anatomical changes in head and neck cancer patients in order to help guide adaptive radiotherapy decisions. Methods: The method, developed in MATLAB, reveals internal anatomical changes based on variations observed in external anatomy. Weekly kV-CBCT scans from 11 Head and neck patients were retrospectively analyzed. The pre-processing step first corrects each CBCT for artifacts and removes pixels from the immobilization mask to produce an accurate external contour of the patient’s skin. After registering the CBCTs to the initial planning CT, the external contours from each CBCT (CBCTn) are transferred to themore » first week — reference — CBCT{sub 1}. Contour radii, defined as the distances between an external contour and the central pixel of each CBCT slice, are calculated for each scan at angular increments of 1 degree. The changes in external anatomy are then quantified by the difference in radial distance between the external contours of CBCT1 and CBCTn. The radial difference is finally displayed on a 2D intensity map (angle vs radial distance difference) in order to highlight regions of interests with significant changes. Results: The 2D radial difference maps provided qualitative and quantitative information, such as the location and the magnitude of external contour divergences and the rate at which these deviations occur. With this method, anatomical changes due to tumor volume shrinkage and patient weight loss were clearly identified and could be correlated with the under-dosage of targets or over-dosage of OARs. Conclusion: This novel method provides an efficient tool to visualize 3D external anatomical modification on a single 2D map. It quickly pinpoints the location of differences in anatomy during the course of radiotherapy, which can help determine if a treatment plan needs to be adapted.« less

  14. Comparing the dosimetric impact of interfractional anatomical changes in photon, proton and carbon ion radiotherapy for pancreatic cancer patients

    NASA Astrophysics Data System (ADS)

    Houweling, Antonetta C.; Crama, Koen; Visser, Jorrit; Fukata, Kyohei; Rasch, Coen R. N.; Ohno, Tatsuya; Bel, Arjan; van der Horst, Astrid

    2017-04-01

    Radiotherapy using charged particles is characterized by a low dose to the surrounding healthy organs, while delivering a high dose to the tumor. However, interfractional anatomical changes can greatly affect the robustness of particle therapy. Therefore, we compared the dosimetric impact of interfractional anatomical changes (i.e. body contour differences and gastrointestinal gas volume changes) in photon, proton and carbon ion therapy for pancreatic cancer patients. In this retrospective planning study, photon, proton and carbon ion treatment plans were created for 9 patients. Fraction dose calculations were performed using daily cone-beam CT (CBCT) images. To this end, the planning CT was deformably registered to each CBCT; gastrointestinal gas volumes were delineated on the CBCTs and copied to the deformed CT. Fraction doses were accumulated rigidly. To compare planned and accumulated dose, dose-volume histogram (DVH) parameters of the planned and accumulated dose of the different radiotherapy modalities were determined for the internal gross tumor volume, internal clinical target volume (iCTV) and organs-at-risk (OARs; duodenum, stomach, kidneys, liver and spinal cord). Photon plans were highly robust against interfractional anatomical changes. The difference between the planned and accumulated DVH parameters for the photon plans was less than 0.5% for the target and OARs. In both proton and carbon ion therapy, however, coverage of the iCTV was considerably reduced for the accumulated dose compared with the planned dose. The near-minimum dose ({{D}98 % } ) of the iCTV reduced with 8% for proton therapy and with 10% for carbon ion therapy. The DVH parameters of the OARs differed less than 3% for both particle modalities. Fractionated radiotherapy using photons is highly robust against interfractional anatomical changes. In proton and carbon ion therapy, such changes can severely reduce the dose coverage of the target.

  15. Anatomic Mesenchymal Stem Cell-Based Engineered Cartilage Constructs for Biologic Total Joint Replacement

    PubMed Central

    Saxena, Vishal; Kim, Minwook; Keah, Niobra M.; Neuwirth, Alexander L.; Stoeckl, Brendan D.; Bickard, Kevin; Restle, David J.; Salowe, Rebecca; Wang, Margaret Ye; Steinberg, David R.

    2016-01-01

    Cartilage has a poor healing response, and few viable options exist for repair of extensive damage. Hyaluronic acid (HA) hydrogels seeded with mesenchymal stem cells (MSCs) polymerized through UV crosslinking can generate functional tissue, but this crosslinking is not compatible with indirect rapid prototyping utilizing opaque anatomic molds. Methacrylate-modified polymers can also be chemically crosslinked in a cytocompatible manner using ammonium persulfate (APS) and N,N,N′,N′-tetramethylethylenediamine (TEMED). The objectives of this study were to (1) compare APS/TEMED crosslinking with UV crosslinking in terms of functional maturation of MSC-seeded HA hydrogels; (2) generate an anatomic mold of a complex joint surface through rapid prototyping; and (3) grow anatomic MSC-seeded HA hydrogel constructs using this alternative crosslinking method. Juvenile bovine MSCs were suspended in methacrylated HA (MeHA) and crosslinked either through UV polymerization or chemically with APS/TEMED to generate cylindrical constructs. Minipig porcine femoral heads were imaged using microCT, and anatomic negative molds were generated by three-dimensional printing using fused deposition modeling. Molded HA constructs were produced using the APS/TEMED method. All constructs were cultured for up to 12 weeks in a chemically defined medium supplemented with TGF-β3 and characterized by mechanical testing, biochemical assays, and histologic analysis. Both UV- and APS/TEMED-polymerized constructs showed increasing mechanical properties and robust proteoglycan and collagen deposition over time. At 12 weeks, APS/TEMED-polymerized constructs had higher equilibrium and dynamic moduli than UV-polymerized constructs, with no differences in proteoglycan or collagen content. Molded HA constructs retained their hemispherical shape in culture and demonstrated increasing mechanical properties and proteoglycan and collagen deposition, especially at the edges compared to the center of these

  16. Anatomically ordered tapping interferes more with one-digit addition than two-digit addition: a dual-task fMRI study.

    PubMed

    Soylu, Firat; Newman, Sharlene D

    2016-02-01

    Fingers are used as canonical representations for numbers across cultures. In previous imaging studies, it was shown that arithmetic processing activates neural resources that are known to participate in finger movements. Additionally, in one dual-task study, it was shown that anatomically ordered finger tapping disrupts addition and subtraction more than multiplication, possibly due to a long-lasting effect of early finger counting experiences on the neural correlates and organization of addition and subtraction processes. How arithmetic task difficulty and tapping complexity affect the concurrent performance is still unclear. If early finger counting experiences have bearing on the neural correlates of arithmetic in adults, then one would expect anatomically and non-anatomically ordered tapping to have different interference effects, given that finger counting is usually anatomically ordered. To unravel these issues, we studied how (1) arithmetic task difficulty and (2) the complexity of the finger tapping sequence (anatomical vs. non-anatomical ordering) affect concurrent performance and use of key neural circuits using a mixed block/event-related dual-task fMRI design with adult participants. The results suggest that complexity of the tapping sequence modulates interference on addition, and that one-digit addition (fact retrieval), compared to two-digit addition (calculation), is more affected from anatomically ordered tapping. The region-of-interest analysis showed higher left angular gyrus BOLD response for one-digit compared to two-digit addition, and in no-tapping conditions than dual tapping conditions. The results support a specific association between addition fact retrieval and anatomically ordered finger movements in adults, possibly due to finger counting strategies that deploy anatomically ordered finger movements early in the development.

  17. Hemodialysis catheter implantation in the axillary vein by ultrasound guidance versus palpation or anatomical reference

    PubMed Central

    Valencia, Cesar A Restrepo; Villa, Carlos A Buitrago; Cardona, Jose A Chacon

    2013-01-01

    Background We compared the results of four different methods of hemodialysis catheter insertion in the medial segment of the axillary vein: ultrasound guidance, palpation, anatomical reference, and prior transient catheter. Methods All patients that required acute or chronic hemodialysis and for whom it was determined impossible or not recommended either to place a catheter in the internal jugular vein (for instance, those patients with a tracheostomy), or to practice arteriovenous fistula or graft; it was then essential to obtain an alternative vascular access. When the procedure of axillary vein catheter insertion was performed in the Renal Care Facility (RCF), ultrasound guidance was used, but in the intensive care unit (ICU), this resource was unavailable, so the palpation or anatomical reference technique was used. Results Two nephrologists with experience in the technique performed 83 procedures during a period lasting 15 years and 8 months (from January 1997–August 2012): 41 by ultrasound guidance; 19 by anatomical references; 15 by palpation of the contiguous axillary artery; and 8 through a temporary axillary catheter previously placed. The ultrasound-guided patients had fewer punctures than other groups, but the value was not statistically significant. Arterial punctures were infrequent in all techniques. Analyzing all the procedure-related complications, such as hematoma, pneumothorax, brachial-plexus injury, as well as the reasons for catheter removal, no differences were observed among the groups. The functioning time was longer in the ultrasound-guided and previous catheter groups. In 15 years and 8 months of surveillance, no clinical or image evidence for axillary vein stenosis was found. Conclusion The ultrasound guide makes the procedure of inserting catheters in the axillary veins easier, but knowledge of the anatomy of the midaxillary region and the ability to feel the axillary artery pulse (for the palpation method) also allow relatively easy

  18. Is the female G-spot truly a distinct anatomic entity?

    PubMed

    Kilchevsky, Amichai; Vardi, Yoram; Lowenstein, Lior; Gruenwald, Ilan

    2012-03-01

    The existence of an anatomically distinct female G-spot is controversial. Reports in the public media would lead one to believe the G-spot is a well-characterized entity capable of providing extreme sexual stimulation, yet this is far from the truth. The aim of this article was to provide an overview of the evidence both supporting and refuting the existence of an anatomically distinct female G-spot. PubMed search for articles published between 1950 and 2011 using key words "G-spot," "Grafenberg spot," "vaginal innervation," "female orgasm," "female erogenous zone," and "female ejaculation." Clinical trials, meeting abstracts, case reports, and review articles that were written in English and published in a peer-reviewed journal were selected for analysis. The main outcome measure of this article was to assess any valid objective data in the literature that scientifically evaluates the existence of an anatomically distinct G-spot. The literature cites dozens of trials that have attempted to confirm the existence of a G-spot using surveys, pathologic specimens, various imaging modalities, and biochemical markers. The surveys found that a majority of women believe a G-spot actually exists, although not all of the women who believed in it were able to locate it. Attempts to characterize vaginal innervation have shown some differences in nerve distribution across the vagina, although the findings have not proven to be universally reproducible. Furthermore, radiographic studies have been unable to demonstrate a unique entity, other than the clitoris, whose direct stimulation leads to vaginal orgasm. Objective measures have failed to provide strong and consistent evidence for the existence of an anatomical site that could be related to the famed G-spot. However, reliable reports and anecdotal testimonials of the existence of a highly sensitive area in the distal anterior vaginal wall raise the question of whether enough investigative modalities have been implemented in

  19. Research on the impact factors of GRACE precise orbit determination by dynamic method

    NASA Astrophysics Data System (ADS)

    Guo, Nan-nan; Zhou, Xu-hua; Li, Kai; Wu, Bin

    2018-07-01

    With the successful use of GPS-only-based POD (precise orbit determination), more and more satellites carry onboard GPS receivers to support their orbit accuracy requirements. It provides continuous GPS observations in high precision, and becomes an indispensable way to obtain the orbit of LEO satellites. Precise orbit determination of LEO satellites plays an important role for the application of LEO satellites. Numerous factors should be considered in the POD processing. In this paper, several factors that impact precise orbit determination are analyzed, namely the satellite altitude, the time-variable earth's gravity field, the GPS satellite clock error and accelerometer observation. The GRACE satellites provide ideal platform to study the performance of factors for precise orbit determination using zero-difference GPS data. These factors are quantitatively analyzed on affecting the accuracy of dynamic orbit using GRACE observations from 2005 to 2011 by SHORDE software. The study indicates that: (1) with the altitude of the GRACE satellite is lowered from 480 km to 460 km in seven years, the 3D (three-dimension) position accuracy of GRACE satellite orbit is about 3˜4 cm based on long spans data; (2) the accelerometer data improves the 3D position accuracy of GRACE in about 1 cm; (3) the accuracy of zero-difference dynamic orbit is about 6 cm with the GPS satellite clock error products in 5 min sampling interval and can be raised to 4 cm, if the GPS satellite clock error products with 30 s sampling interval can be adopted. (4) the time-variable part of earth gravity field model improves the 3D position accuracy of GRACE in about 0.5˜1.5 cm. Based on this study, we quantitatively analyze the factors that affect precise orbit determination of LEO satellites. This study plays an important role to improve the accuracy of LEO satellites orbit determination.

  20. Fabrication and assessment of 3D printed anatomical models of the lower limb for anatomical teaching and femoral vessel access training in medicine.

    PubMed

    O'Reilly, Michael K; Reese, Sven; Herlihy, Therese; Geoghegan, Tony; Cantwell, Colin P; Feeney, Robin N M; Jones, James F X

    2016-01-01

    For centuries, cadaveric dissection has been the touchstone of anatomy education. It offers a medical student intimate access to his or her first patient. In contrast to idealized artisan anatomical models, it presents the natural variation of anatomy in fine detail. However, a new teaching construct has appeared recently in which artificial cadavers are manufactured through three-dimensional (3D) printing of patient specific radiological data sets. In this article, a simple powder based printer is made more versatile to manufacture hard bones, silicone muscles and perfusable blood vessels. The approach involves blending modern approaches (3D printing) with more ancient ones (casting and lost-wax techniques). These anatomically accurate models can augment the approach to anatomy teaching from dissection to synthesis of 3D-printed parts held together with embedded rare earth magnets. Vascular simulation is possible through application of pumps and artificial blood. The resulting arteries and veins can be cannulated and imaged with Doppler ultrasound. In some respects, 3D-printed anatomy is superior to older teaching methods because the parts are cheap, scalable, they can cover the entire age span, they can be both dissected and reassembled and the data files can be printed anywhere in the world and mass produced. Anatomical diversity can be collated as a digital repository and reprinted rather than waiting for the rare variant to appear in the dissection room. It is predicted that 3D printing will revolutionize anatomy when poly-material printing is perfected in the early 21st century. © 2015 American Association of Anatomists.

  1. Correction factors in determining speed of sound among freshmen in undergraduate physics laboratory

    NASA Astrophysics Data System (ADS)

    Lutfiyah, A.; Adam, A. S.; Suprapto, N.; Kholiq, A.; Putri, N. P.

    2018-03-01

    This paper deals to identify the correction factor in determining speed of sound that have been done by freshmen in undergraduate physics laboratory. Then, the result will be compared with speed of sound that determining by senior student. Both of them used the similar instrument, namely resonance tube with apparatus. The speed of sound indicated by senior was 333.38 ms-1 with deviation to the theory about 3.98%. Meanwhile, for freshmen, the speed of sound experiment was categorised into three parts: accurate value (52.63%), middle value (31.58%) and lower value (15.79%). Based on analysis, some correction factors were suggested: human error in determining first and second harmonic, end correction of tube diameter, and another factors from environment, such as temperature, humidity, density, and pressure.

  2. Nasal high flow clears anatomical dead space in upper airway models

    PubMed Central

    Celik, Gülnaz; Feng, Sheng; Bartenstein, Peter; Meyer, Gabriele; Eickelberg, Oliver; Schmid, Otmar; Tatkov, Stanislav

    2015-01-01

    Recent studies showed that nasal high flow (NHF) with or without supplemental oxygen can assist ventilation of patients with chronic respiratory and sleep disorders. The hypothesis of this study was to test whether NHF can clear dead space in two different models of the upper nasal airways. The first was a simple tube model consisting of a nozzle to simulate the nasal valve area, connected to a cylindrical tube to simulate the nasal cavity. The second was a more complex anatomically representative upper airway model, constructed from segmented CT-scan images of a healthy volunteer. After filling the models with tracer gases, NHF was delivered at rates of 15, 30, and 45 l/min. The tracer gas clearance was determined using dynamic infrared CO2 spectroscopy and 81mKr-gas radioactive gamma camera imaging. There was a similar tracer-gas clearance characteristic in the tube model and the upper airway model: clearance half-times were below 1.0 s and decreased with increasing NHF rates. For both models, the anterior compartments demonstrated faster clearance levels (half-times < 0.5 s) and the posterior sections showed slower clearance (half-times < 1.0 s). Both imaging methods showed similar flow-dependent tracer-gas clearance in the models. For the anatomically based model, there was complete tracer-gas removal from the nasal cavities within 1.0 s. The level of clearance in the nasal cavities increased by 1.8 ml/s for every 1.0 l/min increase in the rate of NHF. The study has demonstrated the fast-occurring clearance of nasal cavities by NHF therapy, which is capable of reducing of dead space rebreathing. PMID:25882385

  3. Maximizing Modern Distribution of Complex Anatomical Spatial Information: 3D Reconstruction and Rapid Prototype Production of Anatomical Corrosion Casts of Human Specimens

    ERIC Educational Resources Information Center

    Li, Jianyi; Nie, Lanying; Li, Zeyu; Lin, Lijun; Tang, Lei; Ouyang, Jun

    2012-01-01

    Anatomical corrosion casts of human specimens are useful teaching aids. However, their use is limited due to ethical dilemmas associated with their production, their lack of perfect reproducibility, and their consumption of original specimens in the process of casting. In this study, new approaches with modern distribution of complex anatomical…

  4. Robotic anatomic segmentectomy of the lung: technical aspects and initial results.

    PubMed

    Pardolesi, Alessandro; Park, Bernard; Petrella, Francesco; Borri, Alessandro; Gasparri, Roberto; Veronesi, Giulia

    2012-09-01

    Robotic lobectomy with radical lymph node dissection is a new frontier of minimally invasive thoracic surgery. Series of sublobar anatomic resection for primary initial lung cancers or for metastasis using video-assisted thoracic surgery have been reported but no cases have been so far reported using the robot-assisted approach. We present the technique and surgical outcome of our initial experience. Clinical data of patients undergoing robotic lung anatomic segmentectomy were retrospectively reviewed. All cases were done using the DaVinci System. A 3- or 4-incision strategy with a 3-cm utility incision in the anterior fourth or fifth intercostal space was performed. Individual ligation and division of the hilar structures was performed using Hem-o-Lok (Teleflex Medical, Research Triangle Park, NC) or endoscopic staplers. The parenchyma was transected with endovascular staplers introduced by the bedside assistant mainly through the utility incision. Systematic mediastinal lymph node dissection or sampling was performed. From 2008 to 2010, 17 patients underwent a robot-assisted lung anatomic segmentectomy in two centers. There were 10 women and 7 men with a mean age of 68.2 years (range, 32 to 82). Mean duration of surgery was 189 minutes. There were no major intraoperative complications. Conversion to open procedure was never required. Postoperative morbidity rate was 17.6% with pneumonia in 1 case and prolonged air leaks in 2 patients. Median postoperative stay was 5 days (range, 2 to 14), and postoperative mortality was 0%. Final pathology was non-small cell lung cancer in 8 patient, typical carcinoids in 2, and lung metastases in 7. Robotic anatomic lung segmentectomy is feasible and safe procedure. Robotic system, by improving ergonomic, surgeon view and precise movements, may make minimally invasive segmentectomy easier to adopt and perform. Copyright © 2012 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  5. Outcome Determining Factors for displaced Intra-articular Calcaneal Fractures treated operatively

    PubMed Central

    Chan, KL; Idham, HM; Izani, IM; Nahulan, T

    2015-01-01

    Introduction: Calcaneal fractures are caused by high energy trauma and mostly are intra-articular fractures. Nondisplaced intra-articular calcaneal fracture (IACF) can be treated non-operatively. However, displaced intra-articular need to be reduced and fixed anatomically to facilitate early ankle rehabilitation and minimize functional impairment. This study was done to find out the outcome of the IACF patients who underwent operative treatment. Methods: 62 patients with IACF were selected in this study and had been followed up from June 2009 to May 2013. They were placed into two groups; the operative treated and non-operative treated groups. Bilateral ankle lateral view plain radiographs were taken for comparison of the Bohler and Gissane angles. Both groups of patients were assessed by the Maryland Foot Score (MFS) and the SF-36v2 general health survey questionnaire. The ability of the patients to perform activity of daily living (ADL) and /or return to work (RTW) was assessed as well. Results: The operative treatment group of displaced IACF patients achieved no significant better scores in the mean MFS and SF-36v2 mean scores as compared to non operated cases. There was no difference in RTW between the 2 groups, but earlier ADL was recorded in the operated group. However, this study had found 5 associated factors which causes major effect to the patients’ outcome to treatment. Conclusions: The patient’s compliance with post-operative rehabilitation regimen were found to be significantly related with the outcomes. PMID:28611903

  6. Sonographic investigation of anatomical specimens of infant hip joints.

    PubMed

    Falliner, Axel; Hahne, Hans-Jürgen; Hassenpflug, Joachim

    2002-07-01

    The anatomical foundations of infant hip sonography techniques are ill-defined. We investigated anatomical specimens of infant hip joints in a water bath, with Graf's and Terjesen's methods. Acetabular position was varied in defined increments, with respect to the ultrasound beam. The alpha angles and the femoral head coverage were measured. Plastic acetabular casts were sawn along the sonographic section planes, and the cut sections compared with the sonographic sections. For images to be obtained, which were analysable by the two methods, the ultrasound beam had to intersect with the acetabular inlet plane at defined angles. The acetabular notch had to be anteriorly rotated from the ultrasound beam plane by at least 20 degrees. Beam entry within a 50 degrees sector posterior to the perpendicular on the inlet plane gave analysable images. The alpha angles and femoral head coverage were much affected by coronal-plane transducer tilt. Caudad tilts were associated with lesser values, a fact that should be borne in mind in clinical ultrasound investigations.

  7. Volumetric Nephrogram Represents Renal Function and Complements Aortic Anatomic Severity Grade in Predicting EVAR Outcomes.

    PubMed

    Balceniuk, Mark D; Trakimas, Lauren; Aghaie, Claudia; Mix, Doran; Rasheed, Khurram; Seaman, Matthew; Ellis, Jennifer; Glocker, Roan; Doyle, Adam; Stoner, Michael C

    2018-07-01

    Chronic kidney disease (CKD) is a predictor of poor outcomes for patients undergoing endovascular aortic aneurysm repair (EVAR). Anatomic severity grade (ASG) represents a quantitative mechanism for assessing anatomical suitability for endovascular aortic repair. Anatomic severity grade has been correlated with repair outcomes and resource utilization. The purpose of this study was to identify a novel renal perfusion metric as a way to assist ASG with predicting EVAR outcomes. Retrospective review of a prospectively maintained database identified elective infrarenal aortic aneurysm repair cases. Anatomic grading was undertaken by independent reviewers. Using volumetric software, kidney volume, and a novel measure of kidney functional volume, the volumetric nephrogram (VN) was recorded. Systematic evaluation of the relationship of kidney volume and VN to CKD and ASG was undertaken using linear regression and receiver-operator statistical tools. A total of 386 cases with patient and anatomic data were identified and graded. Mean age was 72.9 ± 0.4 years. Renal volume <281 mL correlated with CKD (area under the curve [AUC] = .708; P ≤ .0001). Volumetric nephrogram <22.5 HU·L correlated with CKD (AUC = 0.764; P ≤ .0001). High (≥15) ASG scores correlated with both renal volume (AUC = .628; P ≤ .0001) and VN (AUC = .628; P ≤ .0001). Regression analysis demonstrated a strong, inverse relationship between ASG and VN ( R 2 = .95). These data demonstrate that VN is a strong predictor of CKD in a large database of patients undergoing elective aneurysm repair. We demonstrate an inverse relationship between renal function and ASG that has not been previously described in the literature. Additionally, we have shown that VN complements ASG as a model of overall cardiovascular health and atherosclerotic burden. Outcomes in patients with poor renal function may be related to anatomical issues in addition to well-described systemic ramifications.

  8. Simultaneous anatomical sketching as learning by doing method of teaching human anatomy

    PubMed Central

    Noorafshan, Ali; Hoseini, Leila; Amini, Mitra; Dehghani, Mohammad-Reza; Kojuri, Javad; Bazrafkan, Leila

    2014-01-01

    Objective: Learning by lecture is a passive experience. Many innovative techniques have been presented to stimulate students to assume a more active attitude toward learning. In this study, simultaneous sketch drawing, as an interactive learning technique was applied to teach anatomy to the medical students. Materials and Methods: We reconstructed a fun interactive model of teaching anatomy as simultaneous anatomic sketching. To test the model's instruction effectiveness, we conducted a quasi- experimental study and then the students were asked to write their learning experiences in their portfolio, also their view was evaluated by a questionnaire. Results: The results of portfolio evaluation revealed that students believed that this method leads to deep learning and understanding anatomical subjects better. Evaluation of the students’ views on this teaching approach was showed that, more than 80% of the students were agreed or completely agreed with this statement that leaning anatomy concepts are easier and the class is less boring with this method. More than 60% of the students were agreed or completely agreed to sketch anatomical figures with professor simultaneously. They also found the sketching make anatomy more attractive and it reduced the time for learning anatomy. These number of students were agree or completely agree that the method help them learning anatomical concept in anatomy laboratory. More than 80% of the students found the simultaneous sketching is a good method for learning anatomy overall. Conclusion: Sketch drawing, as an interactive learning technique, is an attractive for students to learn anatomy. PMID:25013843

  9. Factors determining dengue outbreak in Malaysia.

    PubMed

    Ahmad, Rohani; Suzilah, Ismail; Wan Najdah, Wan Mohamad Ali; Topek, Omar; Mustafakamal, Ibrahim; Lee, Han Lim

    2018-01-01

    A large scale study was conducted to elucidate the true relationship among entomological, epidemiological and environmental factors that contributed to dengue outbreak in Malaysia. Two large areas (Selayang and Bandar Baru Bangi) were selected in this study based on five consecutive years of high dengue cases. Entomological data were collected using ovitraps where the number of larvae was used to reflect Aedes mosquito population size; followed by RT-PCR screening to detect and serotype dengue virus in mosquitoes. Notified cases, date of disease onset, and number and type of the interventions were used as epidemiological endpoint, while rainfall, temperature, relative humidity and air pollution index (API) were indicators for environmental data. The field study was conducted during 81 weeks of data collection. Correlation and Autoregressive Distributed Lag Model were used to determine the relationship. The study showed that, notified cases were indirectly related with the environmental data, but shifted one week, i.e. last 3 weeks positive PCR; last 4 weeks rainfall; last 3 weeks maximum relative humidity; last 3 weeks minimum and maximum temperature; and last 4 weeks air pollution index (API), respectively. Notified cases were also related with next week intervention, while conventional intervention only happened 4 weeks after larvae were found, indicating ample time for dengue transmission. Based on a significant relationship among the three factors (epidemiological, entomological and environmental), estimated Autoregressive Distributed Lag (ADL) model for both locations produced high accuracy 84.9% for Selayang and 84.1% for Bandar Baru Bangi in predicting the actual notified cases. Hence, such model can be used in forestalling dengue outbreak and acts as an early warning system. The existence of relationships among the entomological, epidemiological and environmental factors can be used to build an early warning system for the prediction of dengue outbreak so

  10. Pneumococcal Vaccination Recommendations for Children and Adults by Age and/or Risk Factor

    MedlinePlus

    ... 1 and Adults by Age and/or Risk Factor Routine Recommendations for Pneumococcal Conjugate Vaccine (PCV13) and ... People with Underlying Medical Conditions or Other Risk Factors Risk Group Immuno- competent Functional or anatomic asplenia ...

  11. The effect of peer assisted learning (PAL) on anatomic competencies of prospective student’s biology teachers

    NASA Astrophysics Data System (ADS)

    Diana, S.

    2018-05-01

    Research about the effect of Peer Assisted Learning (PAL) strategy on Plant Anatomy Course, which aims to improve anatomic competencies of prospective student’s biology teacher, has been done. This study used a quasi-experimental pre-test post-test control group design. The draft includes a group of students who were given a pre-test which is then followed by observing the PAL treatment process and post-test. The other students group (control) was given the pre-test and post-test only. The PAL program began with a discussion between the lecturer and the tutor about the pretest results and then discussion between the tutors and their tutees in the class about the responses items. After that, all students were assigned to answer a set of response items, and then did the posttest. The results showed that the PAL strategy can increase student’s anatomic literacy significantly and can increase student’s anatomic lab skills no significantly. Thus the PAL strategy implementation has a potential to improve student’s anatomic competencies. The generally students weaknesses were they lack practice in interpreting of research results in the graphs form and rarely shared about anatomic lab skills. All students respond positively to the PAL strategy.

  12. Comparison of in vitro flows past a mechanical heart valve in anatomical and axisymmetric aorta models

    NASA Astrophysics Data System (ADS)

    Haya, Laura; Tavoularis, Stavros

    2017-06-01

    Flow characteristics past a bileaflet mechanical heart valve were measured under physiological flow conditions in a straight tube with an axisymmetric expansion, similar to vessels used in previous studies, and in an anatomical model of the aorta. We found that anatomical features, including the three-lobed sinus and the aorta's curvature affected significantly the flow characteristics. The turbulent and viscous stresses were presented and discussed as indicators for potential blood damage and thrombosis. Both types of stresses, averaged over the two axial measurement planes, were significantly lower in the anatomical model than in the axisymmetric one. This difference was attributed to the lower height-to-width ratio and more gradual contraction of the anatomical aortic sinus. The curvature of the aorta caused asymmetries in the velocity and stress distributions during forward flow. Secondary flows resulting from the aorta's curvature are thought to have redistributed the fluid stresses transversely, resulting in a more homogeneous stress distribution in the anatomical aortic root than in the axisymmetric root. The results of this study demonstrate the importance of modelling accurately the aortic geometry in experimental and computational studies of prosthetic devices. Moreover, our findings suggest that grafts used for aortic root replacement should approximate as closely as possible the shape of the natural sinuses.

  13. 46 CFR 401.400 - Calculation of pilotage units and determination of weighting factor.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... weighting factor. 401.400 Section 401.400 Shipping COAST GUARD (GREAT LAKES PILOTAGE), DEPARTMENT OF... § 401.400 Calculation of pilotage units and determination of weighting factor. The equivalent pilotage... meters) Pilot Unit=(Length×Breadth×Depth)/10,000 (measured in feet) (b) Weighting factor table: Range of...

  14. Anatomical connections of the functionally-defined “face patches” in the macaque monkey

    PubMed Central

    Saleem, Kadharbatcha S.

    2017-01-01

    The neural circuits underlying face recognition provide a model for understanding visual object representation, social cognition, and hierarchical information processing. A fundamental piece of information lacking to date is the detailed anatomical connections of the face patches. Here, we injected retrograde tracers into four different face patches (PL, ML, AL, AM) to characterize their anatomical connectivity. We found that the patches are strongly and specifically connected to each other, and individual patches receive inputs from extrastriate cortex, the medial temporal lobe, and three subcortical structures (the pulvinar, claustrum, and amygdala). Inputs from prefrontal cortex were surprisingly weak. Patches were densely interconnected to one another in both feedforward and feedback directions, inconsistent with a serial hierarchy. These results provide the first direct anatomical evidence that the face patches constitute a highly specialized system, and suggest that subcortical regions may play a vital role in routing face-related information to subsequent processing stages. PMID:27263973

  15. Effects of Regularisation Priors and Anatomical Partial Volume Correction on Dynamic PET Data

    NASA Astrophysics Data System (ADS)

    Caldeira, Liliana L.; Silva, Nuno da; Scheins, Jürgen J.; Gaens, Michaela E.; Shah, N. Jon

    2015-08-01

    Dynamic PET provides temporal information about the tracer uptake. However, each PET frame has usually low statistics, resulting in noisy images. Furthermore, PET images suffer from partial volume effects. The goal of this study is to understand the effects of prior regularisation on dynamic PET data and subsequent anatomical partial volume correction. The Median Root Prior (MRP) regularisation method was used in this work during reconstruction. The quantification and noise in image-domain and time-domain (time-activity curves) as well as the impact on parametric images is assessed and compared with Ordinary Poisson Ordered Subset Expectation Maximisation (OP-OSEM) reconstruction with and without Gaussian filter. This study shows the improvement in PET images and time-activity curves (TAC) in terms of noise as well as in the parametric images when using prior regularisation in dynamic PET data. Anatomical partial volume correction improves the TAC and consequently, parametric images. Therefore, the use of MRP with anatomical partial volume correction is of interest for dynamic PET studies.

  16. Cluster-based upper body marker models for three-dimensional kinematic analysis: Comparison with an anatomical model and reliability analysis.

    PubMed

    Boser, Quinn A; Valevicius, Aïda M; Lavoie, Ewen B; Chapman, Craig S; Pilarski, Patrick M; Hebert, Jacqueline S; Vette, Albert H

    2018-04-27

    Quantifying angular joint kinematics of the upper body is a useful method for assessing upper limb function. Joint angles are commonly obtained via motion capture, tracking markers placed on anatomical landmarks. This method is associated with limitations including administrative burden, soft tissue artifacts, and intra- and inter-tester variability. An alternative method involves the tracking of rigid marker clusters affixed to body segments, calibrated relative to anatomical landmarks or known joint angles. The accuracy and reliability of applying this cluster method to the upper body has, however, not been comprehensively explored. Our objective was to compare three different upper body cluster models with an anatomical model, with respect to joint angles and reliability. Non-disabled participants performed two standardized functional upper limb tasks with anatomical and cluster markers applied concurrently. Joint angle curves obtained via the marker clusters with three different calibration methods were compared to those from an anatomical model, and between-session reliability was assessed for all models. The cluster models produced joint angle curves which were comparable to and highly correlated with those from the anatomical model, but exhibited notable offsets and differences in sensitivity for some degrees of freedom. Between-session reliability was comparable between all models, and good for most degrees of freedom. Overall, the cluster models produced reliable joint angles that, however, cannot be used interchangeably with anatomical model outputs to calculate kinematic metrics. Cluster models appear to be an adequate, and possibly advantageous alternative to anatomical models when the objective is to assess trends in movement behavior. Copyright © 2018 Elsevier Ltd. All rights reserved.

  17. Assessing the effectiveness of 30% sodium chloride aqueous solution for the preservation of fixed anatomical specimens: a 5-year follow-up study

    PubMed Central

    de Oliveira, Fabrício Singaretti

    2014-01-01

    Anatomical specimens used in human or veterinary anatomy laboratories are usually prepared with formaldehyde (a cancerous and teratogenic substance), glycerin (an expensive and viscous fluid), or ethanol (which is flammable). This research aimed to verify the viability of an aqueous 30% sodium chloride solution for preservation of anatomical specimens previously fixed with formaldehyde. Anatomical specimens of ruminant, carnivorous, equine, swine and birds were used. All were previously fixed with an aqueous 20% formaldehyde solution and held for 7 days in a 10% aqueous solution of the same active ingredient. During the first phase of the experiment, small specimens of animal tissue previously fixed in formaldehyde were distributed in vials with different concentrations of formaldehyde, with or without 30% sodium chloride solution, a group containing only 30% sodium chloride, and a control group containing only water. During this phase, no contamination was observed in any specimen containing 30% sodium chloride solution, whether alone or in combination with different concentrations of formaldehyde. In the second phase of the experiment, the 30% sodium chloride solution, found to be optimal in the first phase of the experiment, was tested for its long-term preservation properties. For a period of 5 years, the preserved specimens were evaluated three times a week for visual contamination, odors, and changes in color and texture. There was no visual contamination or decay found in any specimen. Furthermore, no strange odors, or changes in color or softness were noted. The 30% sodium chloride solution was determined to be effective in the preservation of anatomic specimens previously fixed in formaldehyde. PMID:24762210

  18. Clinical and anatomical observations of a two-headed lamb.

    PubMed

    Fisher, K R; Partlow, G D; Walker, A F

    1986-04-01

    The clinical and anatomical features of a live-born diprosopic lamb are described. There are no complete anatomical analyses of two-faced lambs in the literature despite the frequency of conjoined twinning in sheep. The lamb had two heads fused in the occipital region. Each head had two eyes. The pinnae of the medial ears were fused. Caudal to the neck the lamb appeared grossly normal. The lamb was unable to raise its heads or stand. Both heads showed synchronous sucking motions and cranial reflexes were present. Nystagmus, strabismus, and limb incoordination were present. The respiratory and heart rates were elevated. There was a grade IV murmur over the left heart base and a palpable thrill on the left side. Each head possessed a normal nasopharynx, oropharynx, and tongue. There was a singular laryngopharnyx and esophagus although the hyoid apparatus was partially duplicated. The cranial and cervical musculature reflected the head duplications. The aortic trunk emerged from the right ventricle just to the right of the conus arteriosus. A ventricular septal defect, patent foramen ovale, and ductus arteriosus were present along with malformed atrioventricular valves. Brainstem fusion began at the cranial medulla oblongata between cranial nerves IX and XII. The cerebella were separate but small. The ventromedial structures from each medulla oblongata were compressed into an extraneous midline remnant of tissue which extended caudally to the level of T2. The clinical signs therefore reflected the anatomical anomalies. A possible etiology for this diprosopus might be the presence early in development of an excessively large block of chordamesoderm. This would allow for the formation of two head folds and hence two "heads."

  19. Active suppression of a leaf meristem orchestrates determinate leaf growth

    PubMed Central

    Alvarez, John Paul; Furumizu, Chihiro; Efroni, Idan; Eshed, Yuval; Bowman, John L

    2016-01-01

    Leaves are flat determinate organs derived from indeterminate shoot apical meristems. The presence of a specific leaf meristem is debated, as anatomical features typical of meristems are not present in leaves. Here we demonstrate that multiple NGATHA (NGA) and CINCINNATA-class-TCP (CIN-TCP) transcription factors act redundantly, shortly after leaf initiation, to gradually restrict the activity of a leaf meristem in Arabidopsis thaliana to marginal and basal domains, and that their absence confers persistent marginal growth to leaves, cotyledons and floral organs. Following primordia initiation, the restriction of the broadly acting leaf meristem to the margins is mediated by the juxtaposition of adaxial and abaxial domains and maintained by WOX homeobox transcription factors, whereas other marginal elaboration genes are dispensable for its maintenance. This genetic framework parallels the morphogenetic program of shoot apical meristems and may represent a relic of an ancestral shoot system from which seed plant leaves evolved. DOI: http://dx.doi.org/10.7554/eLife.15023.001 PMID:27710768

  20. Anatomical Knowledge Retention in Third-Year Medical Students Prior to Obstetrics and Gynecology and Surgery Rotations

    ERIC Educational Resources Information Center

    Jurjus, Rosalyn A.; Lee, Juliet; Ahle, Samantha; Brown, Kirsten M.; Butera, Gisela; Goldman, Ellen F.; Krapf, Jill M.

    2014-01-01

    Surgical anatomy is taught early in medical school training. The literature shows that many physicians, especially surgical specialists, think that anatomical knowledge of medical students is inadequate and nesting of anatomical sciences later in the clinical curriculum may be necessary. Quantitative data concerning this perception of an…

  1. Comparative radiographic analysis on the anatomical axis in knee osteoarthritis cases: inter and intraobserver evaluation.

    PubMed

    Matos, Luiz Felipe; Giordano, Marcos; Cardoso, Gustavo Novaes; Farias, Rafael Baptista; E Albuquerque, Rodrigo Pires

    2015-01-01

    To make a comparative inter and intraobserver analysis on measurements of the anatomical axis between panoramic radiographs of the lower limbs in anteroposterior (AP) view with bipedal weight-bearing, on short film. An accuracy study comparing radiographic measurements on 47 knees of patients attending the knee surgery outpatient clinic due to osteoarthritis. The radiographic evaluation used was as standardized for the total knee arthroplasty program, including panoramic AP views of the lower limbs and short radiographs of the knees in AP and lateral views, all with bipedal weight-bearing. Following this, the anatomical axis of the lower limbs or the femorotibial angle was measured by five independent examiners on the panoramic and short AP radiographs; three of the examiners were considered to be more experienced and two, less experienced. All the measurements were made again by the same examiners after an interval of not less than 15 days. The statistical analysis was performed using the intraclass correlation coefficient, in order to evaluate the inter and intraobserver concordance of the anatomical axis measurements. From the statistical analysis, it was observed that there was strongly significant concordance between the anatomical axis measurements on the panoramic and short radiographs, for all the five examiners and for both measurements. Under the conditions studied, short radiographs were equivalent to panoramic radiographs for evaluating the anatomical axis of the lower limbs in patients with advanced osteoarthritis. The measurements used also showed high rates of inter and intraobserver concordance and reproducibility.

  2. Anatomical sciences: A foundation for a solid learning experience in dental technology and dental prosthetics.

    PubMed

    Bakr, Mahmoud M; Thompson, C Mark; Massadiq, Magdalena

    2017-07-01

    Basic science courses are extremely important as a foundation for scaffolding knowledge and then applying it in future courses, clinical situations as well as in a professional career. Anatomical sciences, which include tooth morphology, oral histology, oral embryology, and head and neck anatomy form a core part of the preclinical courses in dental technology programs. In this article, the importance and relevance of anatomical sciences to dental personnel with no direct contact with patients (dental technicians) and limited discipline related contact with patients (dental prosthetists) is highlighted. Some light is shed on the role of anatomical sciences in the pedagogical framework and its significance in the educational process and interprofessional learning of dental technicians and prosthetists using oral biology as an example in the dental curriculum. To conclude, anatomical sciences allow dental technicians and prosthetists to a gain a better insight of how tissues function, leading to a better understanding of diagnosis, comprehensive treatment planning and referrals if needed. Patient communication and satisfaction also increases as a result of this deep understanding of oral tissues. Anatomical sciences bridge the gap between basic science, preclinical, and clinical courses, which leads to a holistic approach in patient management. Finally, treatment outcomes are positively affected due to the appreciation of the macro and micro structure of oral tissues. Anat Sci Educ 10: 395-404. © 2016 American Association of Anatomists. © 2016 American Association of Anatomists.

  3. Occipital neuralgia: anatomic considerations.

    PubMed

    Cesmebasi, Alper; Muhleman, Mitchel A; Hulsberg, Paul; Gielecki, Jerzy; Matusz, Petru; Tubbs, R Shane; Loukas, Marios

    2015-01-01

    Occipital neuralgia is a debilitating disorder first described in 1821 as recurrent headaches localized in the occipital region. Other symptoms that have been associated with this condition include paroxysmal burning and aching pain in the distribution of the greater, lesser, or third occipital nerves. Several etiologies have been identified in the cause of occipital neuralgia and include, but are not limited to, trauma, fibrositis, myositis, fracture of the atlas, and compression of the C-2 nerve root, C1-2 arthrosis syndrome, atlantoaxial lateral mass osteoarthritis, hypertrophic cervical pachymeningitis, cervical cord tumor, Chiari malformation, and neurosyphilis. The management of occipital neuralgia can include conservative approaches and/or surgical interventions. Occipital neuralgia is a multifactorial problem where multiple anatomic areas/structures may be involved with this pathology. A review of these etiologies may provide guidance in better understanding occipital neuralgia. © 2014 Wiley Periodicals, Inc.

  4. Pushing the dead into the next reproductive frontier: post mortem gamete retrieval under the uniform anatomical gift act.

    PubMed

    Spielman, Bethany

    2009-01-01

    In re Matter of Daniel Thomas Christy authorized post mortem gamete retrieval under the most recent revision of the Uniform Anatomical Gift Act. This article recommends that the National Conference of Commissioners on Uniform State Laws explicitly address the issue of post mortem gamete retrieval for reproductive purposes; that legislators specify whether their states will follow the Christy ruling; and that ethics committees and consultants prepare for the questions about human identity and self determination that post mortem gamete retrieval raises.

  5. Predictive models of long-term anatomic outcome in age-related macular degeneration treated with as-needed Ranibizumab.

    PubMed

    Gonzalez-Buendia, Lucia; Delgado-Tirado, Santiago; Sanabria, M Rosa; Fernandez, Itziar; Coco, Rosa M

    2017-08-18

    To analyze predictors and develop predictive models of anatomic outcome in neovascular age-related macular degeneration (AMD) treated with as-needed ranibizumab after 4 years of follow-up. A multicenter consecutive case series non-interventional study was performed. Clinical, funduscopic and OCT characteristics of 194 treatment-naïve patients with AMD treated with as-needed ranibizumab for at least 2 years and up to 4 years were analyzed at baseline, 3 months and each year until the end of the follow-up. Baseline demographic and angiographic characteristics were also evaluated. R Statistical Software was used for statistical analysis. Main outcome measure was final anatomic status. Factors associated with less probability of preserved macula were diagnosis in 2009, older age, worse vision, presence of atrophy/fibrosis, pigment epithelium detachment, and geographic atrophy/fibrotic scar/neovascular AMD in the fellow eye. Factors associated with higher probability of GA were presence of atrophy and greater number of injections, whereas male sex, worse vision, lesser change in central macular thickness and presence of fibrosis were associated with less probability of GA as final macular status. Predictive model of preserved macula vs. GA/fibrotic scar showed sensibility of 77.78% and specificity of 69.09%. Predictive model of GA vs. fibrotic scar showed sensibility of 68.89% and specificity of 72.22%. We identified predictors of final macular status, and developed two predictive models. Predictive models that we propose are based on easily harvested variables, and, if validated, could be a useful tool for individual patient management and clinical research studies.

  6. Economic Analysis of Anatomic Plating Versus Tubular Plating for the Treatment of Fibula Fractures.

    PubMed

    Chang, Gerard; Bhat, Suneel B; Raikin, Steven M; Kane, Justin M; Kay, Andrew; Ahmad, Jamal; Pedowitz, David I; Krieg, James

    2018-03-01

    Ankle fractures are among the most common injuries requiring operative management. Implant choices include one-third tubular plates and anatomically precontoured plates. Although cadaveric studies have not revealed biomechanical differences between various plate constructs, there are substantial cost differences. This study sought to characterize the economic implications of implant choice. A retrospective review was undertaken of 201 consecutive patients with operatively treated OTA type 44B and 44C ankles. A Nationwide Inpatient Sample query was performed to estimate the incidence of ankle fractures requiring fibular plating, and a Monte Carlo simulation was conducted with the estimated at-risk US population for associated plate-specific costs. The authors estimated an annual incidence of operatively treated ankle fractures in the United States of 59,029. The average cost was $90.86 (95% confidence interval, $90.84-$90.87) for a one-third tubular plate vs $746.97 (95% confidence interval, $746.55-$747.39) for an anatomic plate. Across the United States, use of only one-third tubular plating over anatomic plating would result in statistically significant savings of $38,729,517 (95% confidence interval, $38,704,773-$38,754,261; P<.0001). General use of one-third tubular plating instead of anatomic plating whenever possible for fibula fractures could result in cost savings of up to nearly $40 million annually in the United States. Unless clinically justifiable on a per-case basis, or until the advent of studies showing substantial clinical benefit, there currently is no reason for the increased expense from widespread use of anatomic plating for fractures amenable to one-third tubular plating. [Orthopedics. 2018; 41(2):e252-e256.]. Copyright 2018, SLACK Incorporated.

  7. The Effect of Social and Classroom Ecological Factors on Promoting Self-Determination in Elementary School

    PubMed Central

    Cho, Hyunjeong; Wehmeyer, Michael; Kingston, Neil

    2014-01-01

    Promoting the self-determination of students with disabilities as a means to access the general curriculum has been the subject of research in recent years, as has the importance of efforts to promote self-determination during elementary years. To examine the status of such efforts in the field, 203 elementary special educators were surveyed in 23 states to determine how (a) classroom instructional practices or strategies, (b) classroom ecological or setting variables, and (c) self-reported barriers to promoting self-determination affected their perceptions of the importance of teaching self-determination and the frequency with which they did so. Results indicated that special educators’ perceived importance of teaching self-determination was not impacted by classroom instructional factors, but was affected by classroom ecological factors. Classroom ecological factors were not, however, significant in the frequency with which teachers provided instruction on self-determination, but classroom instructional practices were. Limitations and implications are discussed, and suggestions for future research are offered. PMID:25067895

  8. The Anatomical Society core regional anatomy syllabus for undergraduate medicine.

    PubMed

    Smith, C F; Finn, G M; Stewart, J; Atkinson, M A; Davies, D C; Dyball, R; Morris, J; Ockleford, C; Parkin, I; Standring, S; Whiten, S; Wilton, J; McHanwell, S

    2016-01-01

    The Anatomical Society's core syllabus for anatomy (2003 and later refined in 2007) set out a series of learning outcomes that an individual medical student should achieve on graduation. The core syllabus, with 182 learning outcomes grouped in body regions, referenced in the General Medical Council's Teaching Tomorrow's Doctors, was open to criticism on the grounds that the learning outcomes were generated by a relatively small group of anatomists, albeit some of whom were clinically qualified. We have therefore used a modified Delphi technique to seek a wider consensus. A Delphi panel was constructed involving 'experts' (n = 39). The revised core syllabus of 156 learning outcomes presented here is applicable to all medical programmes and may be used by curriculum planners, teachers and students alike in addressing the perennial question: 'What do I need to know ?' © 2015 Anatomical Society.

  9. ANATOMICAL RECONSTRUCTION OF ANTERIOR CRUCIATE LIGAMENT OF THE KNEE: DOUBLE BAND OR SINGLE BAND?

    PubMed

    Zanella, Luiz Antonio Zanotelli; Junior, Adair Bervig; Badotti, Augusto Alves; Michelin, Alexandre Froes; Algarve, Rodrigo Ilha; de Quadros Martins, Cesar Antonio

    2012-01-01

    To evaluate the double-band and single-band techniques for anatomical reconstruction of the anterior cruciate ligament of the knee and demonstrate that the double-band technique not only provides greater anterior stability but also causes less pain and a better subjective patient response. We selected 42 patients who underwent anterior cruciate ligament reconstruction, by means of either the single-band anatomical reconstruction technique, using flexor tendon grafts with two tunnels, or the double-band anatomical reconstruction technique, using four tunnels and grafts from the semitendinosus and gracilis tendons. All fixations were performed using interference screws. There was no variation in the sample. Before the operation, the objective and subjective IKDC scores, Lysholm score and length of time with the injury were evaluated. All these variables were reassessed six months later, and the KT-1000 correlation with the contralateral knee was also evaluated. There was no significant difference between the two groups in subjective evaluations, but the single-band group showed better results in relation to range of motion and objective evaluations including KT-1000 (with statistical significance). Our study demonstrated that there was no difference between the two groups in subjective evaluations, but better results were found using the single-band anatomical technique, in relation to objective evaluations.

  10. Root anatomical phenes predict root penetration ability and biomechanical properties in maize (Zea Mays)

    PubMed Central

    Chimungu, Joseph G.; Loades, Kenneth W.; Lynch, Jonathan P.

    2015-01-01

    The ability of roots to penetrate hard soil is important for crop productivity but specific root phenes contributing to this ability are poorly understood. Root penetrability and biomechanical properties are likely to vary in the root system dependent on anatomical structure. No information is available to date on the influence of root anatomical phenes on root penetrability and biomechanics. Root penetration ability was evaluated using a wax layer system. Root tensile and bending strength were evaluated in plant roots grown in the greenhouse and in the field. Root anatomical phenes were found to be better predictors of root penetrability than root diameter per se and associated with smaller distal cortical region cell size. Smaller outer cortical region cells play an important role in stabilizing the root against ovalization and reducing the risk of local buckling and collapse during penetration, thereby increasing root penetration of hard layers. The use of stele diameter was found to be a better predictor of root tensile strength than root diameter. Cortical thickness, cortical cell count, cortical cell wall area and distal cortical cell size were stronger predictors of root bend strength than root diameter. Our results indicate that root anatomical phenes are important predictors for root penetrability of high-strength layers and root biomechanical properties. PMID:25903914

  11. ANATOMICAL RECONSTRUCTION OF ANTERIOR CRUCIATE LIGAMENT OF THE KNEE: DOUBLE BAND OR SINGLE BAND?

    PubMed Central

    Zanella, Luiz Antonio Zanotelli; Junior, Adair Bervig; Badotti, Augusto Alves; Michelin, Alexandre Froes; Algarve, Rodrigo Ilha; de Quadros Martins, Cesar Antonio

    2015-01-01

    Objective: To evaluate the double-band and single-band techniques for anatomical reconstruction of the anterior cruciate ligament of the knee and demonstrate that the double-band technique not only provides greater anterior stability but also causes less pain and a better subjective patient response. Methods: We selected 42 patients who underwent anterior cruciate ligament reconstruction, by means of either the single-band anatomical reconstruction technique, using flexor tendon grafts with two tunnels, or the double-band anatomical reconstruction technique, using four tunnels and grafts from the semitendinosus and gracilis tendons. All fixations were performed using interference screws. There was no variation in the sample. Before the operation, the objective and subjective IKDC scores, Lysholm score and length of time with the injury were evaluated. All these variables were reassessed six months later, and the KT-1000 correlation with the contralateral knee was also evaluated. Results: There was no significant difference between the two groups in subjective evaluations, but the single-band group showed better results in relation to range of motion and objective evaluations including KT-1000 (with statistical significance). Conclusion: Our study demonstrated that there was no difference between the two groups in subjective evaluations, but better results were found using the single-band anatomical technique, in relation to objective evaluations. PMID:27042621

  12. Double-Outlet Right Ventricle With Noncommitted Ventricular Septal Defect and 2 Adequate Ventricles: Is Anatomical Repair Advantageous?

    PubMed

    Villemain, Olivier; Bonnet, Damien; Houyel, Lucile; Vergnat, Mathieu; Ladouceur, Magalie; Lambert, Virginie; Jalal, Zakaria; Vouhé, Pascal; Belli, Emre

    The management of double-outlet right ventricle associated with anatomically noncommitted ventricular septal defect constitutes a surgical challenge. The limits for, and the specific outcomes after anatomical vs univentricular repair still remain to be established. Between 1993 and 2011, 36 consecutive patients presenting with double-outlet right ventricle or noncommitted ventricular septal defect (21 inlet, 10 muscular, and 5 central perimembranous) and 2 adequately sized ventricles underwent surgical repair at 2 centers. Right ventricular outflow tract obstruction was present in 18 of 36 patients (50%). A total of 21 patients had undergone previous palliative procedures. Anatomical repair (group I) by means of intraventricular baffle construction was performed in 24 (associated right ventricular outflow tract reconstruction in 12 and arterial switch in 5) at a median age of 10.5 months. Ventricular septal defect was surgically enlarged in 12 (50%) patients. The remaining 12 patients underwent univentricular repair (group II). There were 4 hospital deaths (11%), all in group I (P = 0.30 vs group II). A total of 8 of 20 patients in group I survivors underwent 13 reoperations after a median delay of 24 months: subaortic stenosis was the main cause for reoperation in 6 of 8 patients. There was 1 late death in group I and 2 late deaths in group II. The median follow-up was 5.6 years (95% CI: 0.2-9.8). The 10- year actuarial survival rate and freedom from reoperation were 74.7 ± 5% and 58 ± 5% in group I and 71 ± 7% and 70 ± 7% in group II, respectively. At the last visit, all survivors were in New York Heart Association class I-II. Univariate analysis showed that atrioventricular septal defect and isolated mitral cleft were associated with death (P = 0.04) and need for reoperation (P = 0.038). In conclusion, anatomical repair, associated with substantial rates of mortality and need for reoperation, should be considered with caution. Associated atrioventricular

  13. Anatomical basis for impotence following haemorrhoid sclerotherapy.

    PubMed Central

    Pilkington, S. A.; Bateman, A. C.; Wombwell, S.; Miller, R.

    2000-01-01

    Impotence has been reported as a rare but important complication of sclerotherapy for haemorrhoids. The relationship between the anterior wall of the rectum and the periprostatic parasympathetic nerves responsible for penile erection was studied to investigate a potential anatomical explanation for this therapeutic complication. A tissue block containing the anal canal, rectum and prostate was removed from each of six male cadaveric subjects. The dimensions of the components of the rectal wall and the distance between the rectal lumen and parasympathetic nerves in the periprostatic plexus were measured in horizontal transverse histological sections of the tissue blocks at the level of the lower prostate gland (i.e. the correct level for sclerosant injection). The correct site of sclerosant in the submucosa was on average 0.6 mm (SD 0.3 mm) deep to the rectal mucosal surface and only 0.7 mm (SD 0.5 mm) in thickness. The nearest parasympathetic ganglion cells were a mean of only 8.1 mm (SD 2.0 mm) deep to the rectal lumen. The close proximity of the rectum to the periprostatic parasympathetic nerves defines an anatomical basis for impotence following sclerotherapy. This emphasises the need for all practitioners to be particularly careful when injecting in this area and for strict supervision of trainees. Images Figure 1 Figure 2 PMID:11041026

  14. [Anatomical study of men's nipple areola complex].

    PubMed

    Vaucher, R; Dast, S; Assaf, N; Sinna, R

    2016-06-01

    The surgical approach of gynecomastia, sexual reassignment surgery in female-to-male transsexuals and the increase of number of obese wishing to turn to plastic surgery led us to deepen the anatomical knowledge of the nipple areola complex (NAC) in men, poorly retailed in the literature. By inspiring us of the methodology of a Japanese study, we studied 50 healthy volunteers male, from 18 to 55 years old, from July till August 2015. We measured various distances relative to the NAC to define its vertical and horizontal position, as well as the internipple distance according to the size, to the weight and to the body mass index (BMI). At the end of the analysis, we were able to underline a lower vertical thoracic position of the NAC in the tall category of person, a more side horizontal position to the subject presenting a high BMI and a linear relation between the BMI and the internipple (Em) defined by (Em)=8.96×BMI. The surgeon's judgment and the desires of the patient are essentials basis of therapeutics decisions that could be lean on this anatomical study, which allowed to establish an idea of the cartography of the NAC in man. It will be interesting and necessary to confront it with other studies with larger scale. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  15. 45 CFR 150.317 - Factors CMS uses to determine the amount of penalty.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... level of financial and other impacts on affected individuals. (3) Other factors as justice may require. ... 45 Public Welfare 1 2012-10-01 2012-10-01 false Factors CMS uses to determine the amount of... With Respect to Issuers and Non-Federal Governmental Plans-Civil Money Penalties § 150.317 Factors CMS...

  16. Multivariate pattern analysis reveals anatomical connectivity differences between the left and right mesial temporal lobe epilepsy.

    PubMed

    Fang, Peng; An, Jie; Zeng, Ling-Li; Shen, Hui; Chen, Fanglin; Wang, Wensheng; Qiu, Shijun; Hu, Dewen

    2015-01-01

    Previous studies have demonstrated differences of clinical signs and functional brain network organizations between the left and right mesial temporal lobe epilepsy (mTLE), but the anatomical connectivity differences underlying functional variance between the left and right mTLE remain uncharacterized. We examined 43 (22 left, 21 right) mTLE patients with hippocampal sclerosis and 39 healthy controls using diffusion tensor imaging. After the whole-brain anatomical networks were constructed for each subject, multivariate pattern analysis was applied to classify the left mTLE from the right mTLE and extract the anatomical connectivity differences between the left and right mTLE patients. The classification results reveal 93.0% accuracy for the left mTLE versus the right mTLE, 93.4% accuracy for the left mTLE versus controls and 90.0% accuracy for the right mTLE versus controls. Compared with the right mTLE, the left mTLE exhibited a different connectivity pattern in the cortical-limbic network and cerebellum. The majority of the most discriminating anatomical connections were located within or across the cortical-limbic network and cerebellum, thereby indicating that these disease-related anatomical network alterations may give rise to a portion of the complex of emotional and memory deficit between the left and right mTLE. Moreover, the orbitofrontal gyrus, cingulate cortex, hippocampus and parahippocampal gyrus, which exhibit high discriminative power in classification, may play critical roles in the pathophysiology of mTLE. The current study demonstrated that anatomical connectivity differences between the left mTLE and the right mTLE may have the potential to serve as a neuroimaging biomarker to guide personalized diagnosis of the left and right mTLE.

  17. Anatomically constrained neural network models for the categorization of facial expression

    NASA Astrophysics Data System (ADS)

    McMenamin, Brenton W.; Assadi, Amir H.

    2004-12-01

    The ability to recognize facial expression in humans is performed with the amygdala which uses parallel processing streams to identify the expressions quickly and accurately. Additionally, it is possible that a feedback mechanism may play a role in this process as well. Implementing a model with similar parallel structure and feedback mechanisms could be used to improve current facial recognition algorithms for which varied expressions are a source for error. An anatomically constrained artificial neural-network model was created that uses this parallel processing architecture and feedback to categorize facial expressions. The presence of a feedback mechanism was not found to significantly improve performance for models with parallel architecture. However the use of parallel processing streams significantly improved accuracy over a similar network that did not have parallel architecture. Further investigation is necessary to determine the benefits of using parallel streams and feedback mechanisms in more advanced object recognition tasks.

  18. Anatomically constrained neural network models for the categorization of facial expression

    NASA Astrophysics Data System (ADS)

    McMenamin, Brenton W.; Assadi, Amir H.

    2005-01-01

    The ability to recognize facial expression in humans is performed with the amygdala which uses parallel processing streams to identify the expressions quickly and accurately. Additionally, it is possible that a feedback mechanism may play a role in this process as well. Implementing a model with similar parallel structure and feedback mechanisms could be used to improve current facial recognition algorithms for which varied expressions are a source for error. An anatomically constrained artificial neural-network model was created that uses this parallel processing architecture and feedback to categorize facial expressions. The presence of a feedback mechanism was not found to significantly improve performance for models with parallel architecture. However the use of parallel processing streams significantly improved accuracy over a similar network that did not have parallel architecture. Further investigation is necessary to determine the benefits of using parallel streams and feedback mechanisms in more advanced object recognition tasks.

  19. Anatomic feature of deltoid ligament attachment in posteromedial osteochondral lesion of talar dome.

    PubMed

    Nakasa, Tomoyuki; Sawa, Mikiya; Ikuta, Yasunari; Yoshikawa, Masahiro; Tsuyuguchi, Yusuke; Adachi, Nobuo

    2018-03-01

    Osteochondral lesions of the talus (OLT) are recognized as being commonly associated with trauma. However, the etiology of OLT remains unclear. In the case of a posteromedial lesion of OLT (medial OLT), the deep layer of the deltoid ligament is located close to the medial OLT, and this relationship between a medial lesion and deltoid ligament could be a risk factor for medial OLT. The purpose of this study is to investigate the unique anatomic feature of the deep deltoid attachment to the talus in patients with medial OLT compared with patients with non-medial OLT. Forty ankles with medial OLT and 40 ankles without medial OLT were retrospectively reviewed in this study. On the coronal images of MRI, the attachment of deltoid ligament was measured. The continuity of the osteochondral fragment and its bed was evaluated on MRI and arthroscopic findings. Coronal MRI images showed that the attachment of the deep deltoid ligament to the medial OLT was broader and located more proximally than in non-medial OLT. The continuity of fibers from the insertion site of deltoid ligament to the talus to the osteochondral fragment was observed (76.7%). In the arthroscopic findings, the osteochondral fragment was obviously connected to the talus at the medial site in 85.2% of feet. The location of the deep deltoid ligament attachment to the medial OLT was more proximal and there was the possibility of these anatomic feature might contribute to the pathogenesis of medial OLT. Copyright © 2017 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  20. The AEO, an Ontology of Anatomical Entities for Classifying Animal Tissues and Organs

    PubMed Central

    Bard, Jonathan B. L.

    2012-01-01

    This paper describes the AEO, an ontology of anatomical entities that expands the common anatomy reference ontology (CARO) and whose major novel feature is a type hierarchy of ~160 anatomical terms. The breadth of the AEO is wider than CARO as it includes both developmental and gender-specific classes, while the granularity of the AEO terms is at a level adequate to classify simple-tissues (~70 classes) characterized by their containing a predominantly single cell-type. For convenience and to facilitate interoperability, the AEO contains an abbreviated version of the ontology of cell-types (~100 classes) that is linked to these simple-tissue types. The AEO was initially based on an analysis of a broad range of animal anatomy ontologies and then upgraded as it was used to classify the ~2500 concepts in a new version of the ontology of human developmental anatomy (www.obofoundry.org/), a process that led to significant improvements in its structure and content, albeit with a possible focus on mammalian embryos. The AEO is intended to provide the formal classification expected in contemporary ontologies as well as capturing knowledge about anatomical structures not currently included in anatomical ontologies. The AEO may thus be useful in increasing the amount of tissue and cell-type knowledge in other anatomy ontologies, facilitating annotation of tissues that share common features, and enabling interoperability across anatomy ontologies. The AEO can be downloaded from http://www.obofoundry.org/. PMID:22347883