Sample records for factors influencing prosthetic

  1. Factors influencing the cost of prosthetic joint infection treatment.

    PubMed

    Peel, T N; Cheng, A C; Lorenzo, Y P; Kong, D C M; Buising, K L; Choong, P F M

    2013-11-01

    Prosthetic joint infection (PJI) is associated with significant costs to the healthcare system. Current literature examines the cost of specific treatment modalities without assessing other cost drivers for PJI. To examine the overall cost of the treatment of PJI and to identify factors associated with management costs. The costs of treatment of prosthetic joint infections were examined in 139 patients across 10 hospitals over a 3-year period (January 2006 to December 2008). Cost calculations included hospitalization costs, surgical costs, hospital-in-the-home costs and antibiotic therapy costs. Negative binomial regression analysis was performed to model factors associated with total cost. The median cost of treating prosthetic joint infection per patient was Australian $34,800 (interquartile range: 20,305, 56,929). The following factors were associated with increased treatment costs: septic revision arthroplasty (67% increase in treatment cost; P = 0.02), hypotension at presentation (70% increase; P = 0.03), polymicrobial infections (41% increase; P = 0.009), surgical treatment with one-stage exchange (100% increase; P = 0.002) or resection arthroplasty (48% increase; P = 0.001) were independently associated with increased treatment costs. Culture-negative prosthetic joint infections were associated with decreased costs (29% decrease in treatment cost; P = 0.047). Treatment failure was associated with 156% increase in treatment costs. This study identifies clinically important factors influencing treatment costs that may be of relevance to policy-makers, particularly in the setting of hospital reimbursement and guiding future research into cost-effective preventive strategies. Copyright © 2013 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  2. Factors influencing evidence-based practice in prosthetics and orthotics.

    PubMed

    Andrysek, Jan; Christensen, James; Dupuis, Annie

    2011-03-01

    The importance of evidence-based practice is being recognized across a broad range of healthcare disciplines as a means for improving patient outcomes and also efficiently managing healthcare resources. The objective of this work was to obtain information from clinicians about the underlying barriers and facilitators relating to evidence-based practice in prosthetics and orthotics. Cross sectional survey. An internet survey was developed and distributed to 300 prosthetists and orthotists currently practicing in Canada. A principal component factor analysis of the survey results revealed ten primary factors affecting evidence-based practice. These include time constraints, workload and system demands, limited relevant evidence from research, and gaps in skills and knowledge required to perform evidence-based practice. Clinicians value research as a means of improving clinical practice, but they are faced with a number of practical barriers in performing evidence-based practice. This study provides empirical data about the underlying barriers and facilitators relating to evidence-based practice in prosthetics and orthotics. Such data are essential in order to inform those involved in improving existing clinical practices, including educators, professional organizations, and governing bodies.

  3. Factors Associated with Prosthetic Looseness in Lower Limb Amputees.

    PubMed

    Phonghanyudh, Thong; Sutpasanon, Taweesak; Hathaiareerug, Chanasak; Devakula, M L Buddhibongsa; Kumnerddee, Wipoo

    2015-12-01

    To determine the factors associated with prosthetic looseness in lower limb amputees in Sisaket province. The present was a cross-sectional descriptive study. Subjects were lower limb amputees who previously obtained prostheses and required prosthetic replacements at the mobile prosthetic laboratory unit under the Prostheses Foundation of H.R.H. the Princess Mother at Khun Han Hospital, Sisaket province, in February 2013. Data including participant characteristics, prosthetic looseness data, and various variables were collected by direct semi-structured interview. Energy expenditures in physical activities were measured using the Thai version of the short format international physical activity questionnaire. Data between participants with and without prosthetic looseness were compared to determine prosthetic loosening associated factors. Among 101 participants enrolled, 33 (32.7%) had prosthetic looseness with average onset of 1.76 ± 1.67 years. Diabetes mellitus was the only significant factor associated with prosthetic looseness from both univariate and multivariate analyses (HR = 7.05, p = 0.002 and HR = 5.93, p = 0.007 respectively). Among the lower limb amputees in Sisaket province, diabetes mellitus was the only factor associated with prosthetic looseness. Therefore, diabetic screening should be supplemented in lower limb amputee assessment protocol. In addition, we recommend that amputees with diabetes mellitus should receive prosthesis check out at approximately

  4. Influence of Prosthetic Screw Material on Joint Stability in Passive and Non-Passive Implant-Supported Dentures

    PubMed Central

    Spazzin, Aloísio Oro; Henriques, Guilherme Elias Pessanha; de Arruda Nóbilo, Mauro Antônio; Consani, Rafael Leonardo Xediek; Correr-Sobrinho, Lourenço; Mesquita, Marcelo Ferraz

    2009-01-01

    Objectives: This study evaluated the influence of prosthetic screw material on joint stability in implantsupported dentures at two levels of fit. Methods: Ten mandibular implant-supported dentures were fabricated. Twenty cast models were fabricated using these dentures. Four groups (n=10) were tested, according to the vertical fit of the dentures [passive and non-passive] and prosthetic screw materials [titanium (Ti) or gold (Au) alloy]. The one-screw test was performed to quantify the vertical misfits using an optic microscope. The loosening torque for the prosthetic screws was measured 24 hours after the tightening torque (10 Ncm) using a digital torque meter. Data were analyzed by two-way ANOVA and Tukey’s test (α=0.05). Results: Overall, dentures with passive fit and Ti screws resulted in significantly higher loosening torque of the prosthetic screws (p<0.05). No significant interaction was found between fit level and screw material (p=0.199). The prosthetic screw material and fit of implant-supported dentures have an influence on screw joint stability. Ti screws presented higher joint stability than Au screws and minimum of misfit should be found clinically to improve the mechanical behavior of the screw joint. PMID:20148135

  5. Systematic review of some prosthetic risk factors for periimplantitis.

    PubMed

    Pesce, Paolo; Canullo, Luigi; Grusovin, Maria Gabriella; de Bruyn, Hugo; Cosyn, Jan; Pera, Paolo

    2015-09-01

    The recent literature underlines a correlation between plaque and the development of periimplantitis but neglects the importance of the prosthetic factors. The purpose of this systematic review was to appraise the available literature to evaluate the role played by cement excess and misfitting components on the development of periimplantitis. An electronic search restricted to the English language was performed in PubMed, Embase, and the Cochrane Register up to September 1, 2014, based on a selected search algorithm. Only cohort studies and case-control studies were included without additional restrictions. The presence of periimplantitis and implant failure were considered primary and secondary outcome variables. The search produced 275 potentially relevant titles, of which only 2 were found eligible. They showed a correlation in cemented implant prostheses between cement excess and the presence of periimplant disease, especially in patients with a history of periodontal disease. After cement excess removal by means of debridement, disease symptoms disappeared around most of the implants. Scientific articles on prosthetic risk factors for periimplantitis are scarce. Although the studies found on cement remnants have a high risk for bias, cement excess seems to be associated with mucositis and possibly with periimplantitis, especially in patients with a history of periodontal disease. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  6. Influence of the prosthetic arm length (palatal position) of zygomatic implants upon patient satisfaction

    PubMed Central

    Pellicer-Chover, Hilario; Cervera-Ballester, Juan; Peñarrocha-Oltra, David; Bagán, Leticia; Peñarrocha-Diago, María

    2016-01-01

    Background To assess the influence of the prosthetic arm length (palatal position) of zygomatic implants upon patient comfort and stability, speech, functionality and overall satisfaction. Material and Methods A retrospective clinical study was made of patients subjected to rehabilitation of atrophic maxilla with complete maxillary implant-supported fixed prostheses involving a minimum of two zygomatic implants (one on each side) in conjunction with premaxillary implants, and with 12 months of follow-up after implant loading. Subjects used a VAS to score general satisfaction, comfort and stability, speech and functionality, and the results were analyzed in relation to the prosthetic arm length of the zygomatic implants 12 months after prosthetic delivery. Results Twenty-two patients participated in the study, receiving 22 prostheses anchored on 148 implants (44 were zygomatic and 94 were conventional implants). The mean right and left prosthetic arm length was 5.9±2.4 mm and 6.1±2.7 mm, respectively, with no statistically significant differences between them (p=0.576). The mean scores referred to comfort/retention, speech, functionality and overall satisfaction were high - no correlation being found between prosthetic arm length and patient satisfaction (p=0.815). Conclusions No relationship could be identified between prosthetic arm length (palatal position) and patient satisfaction. Key words:Zygomatic implants, patient satisfaction, zygomatic prosthesis, prosthetic arm length. PMID:26946206

  7. Deep pain sensitivity is correlated with oral-health-related quality of life but not with prosthetic factors in complete denture wearers

    PubMed Central

    COSTA, Yuri Martins; PORPORATTI, André Luís; HILGENBERG-SYDNEY, Priscila Brenner; BONJARDIM, Leonardo Rigoldi; CONTI, Paulo César Rodrigues

    2015-01-01

    ABSTRACT Low pressure Pain Threshold (PPT) is considered a risk factor for Temporomandibular Disorders (TMD) and is influenced by psychological variables. Objectives To correlate deep pain sensitivity of masticatory muscles with prosthetic factors and Oral-Health-Related Quality of Life (OHRQoL) in completely edentulous subjects. Material and Methods A total of 29 complete denture wearers were recruited. The variables were: a) Pressure Pain Threshold (PPT) of the masseter and temporalis; b) retention, stability, and tooth wear of dentures; c) Vertical Dimension of Occlusion (VDO); d) Oral Health Impact Profile (OHIP) adapted to orofacial pain. The Kolmogorov-Smirnov test, the Pearson Product-Moment correlation coefficient, the Spearman Rank correlation coefficient, the Point-Biserial correlation coefficient, and the Bonferroni correction (α=1%) were applied to the data. Results The mean age (standard deviation) of the participants was of 70.1 years (9.5) and 82% of them were females. There were no significant correlations with prosthetic factors, but significant negative correlations were found between the OHIP and the PPT of the anterior temporalis (r=-0.50, 95% CI-0.73 to 0.17, p=0.005). Discussion The deep pain sensitivity of masticatory muscles in complete dentures wearers is associated with OHRQoL, but not with prosthetic factors. PMID:26814457

  8. Clinical Presentation, Risk Factors, and Outcomes of Hematogenous Prosthetic Joint Infection in Patients with Staphylococcus aureus Bacteremia.

    PubMed

    Tande, Aaron J; Palraj, Bharath Raj; Osmon, Douglas R; Berbari, Elie F; Baddour, Larry M; Lohse, Christine M; Steckelberg, James M; Wilson, Walter R; Sohail, M Rizwan

    2016-02-01

    Staphylococcus aureus bacteremia is a life-threatening condition that may lead to metastatic infection, including prosthetic joint infection. To assess clinical factors associated with hematogenous prosthetic joint infection, we retrospectively reviewed all patients with a joint arthroplasty in place at the time of a first episode of S. aureus bacteremia over a 5-year period at our institution. Patients with postsurgical prosthetic joint infection without hematogenous prosthetic joint infection were excluded. There were 85 patients (143 arthroplasties) with either no prosthetic joint infection (n = 50; 58.8%) or hematogenous prosthetic joint infection in at least one arthroplasty (n = 35; 41.2%). The odds of hematogenous prosthetic joint infection was significantly increased among patients with community-acquired S. aureus bacteremia (odds ratio [OR] 18.07; 95% confidence interval [CI] 2.64-infinity; P = .001), as compared with nosocomial S. aureus bacteremia, in which there were no patients with hematogenous prosthetic joint infection. After adjusting for S. aureus bacteremia classification, the presence of ≥3 joint arthroplasties in place was associated with a nearly ninefold increased odds of hematogenous prosthetic joint infection as compared with those with 1-2 joint arthroplasties in place (OR 8.55; 95% CI 1.44-95.71; P = .012). All but one joint with prosthetic joint infection demonstrated at least one clinical feature suggestive of infection. There were 4 additional S. aureus prosthetic joint infections diagnosed during a median of 3.4 years of follow-up post hospitalization for S. aureus bacteremia. Prosthetic joint infection is frequent in patients with existing arthroplasties and concomitant S. aureus bacteremia, particularly with community-acquired S. aureus bacteremia and multiple prostheses. In contrast, occult S. aureus prosthetic joint infection without clinical features suggestive of prosthetic joint infection at the time of S. aureus bacteremia

  9. Prosthetic Joint Infections

    PubMed Central

    Aslam, Saima; Darouiche, Rabih O.

    2012-01-01

    Prosthetic joint infections represent a major therapeutic challenge for both healthcare providers and patients. This paper reviews the predisposing factors, pathogenesis, microbiology, diagnosis, treatment and prophylaxis of prosthetic joint infection. The most optimal management strategy should be identified based on a number of considerations including type and duration of infection, antimicrobial susceptibility of the infecting pathogen, condition of infected tissues and bone stock, patient wishes and functional status. PMID:22847032

  10. The influence of staff training and education on prosthetic and orthotic service quality: A scoping review.

    PubMed

    Forghany, Saeed; Sadeghi-Demneh, Ebrahim; Trinler, Ursula; Onmanee, Pornsuree; Dillon, Michael P; Baker, Richard

    2018-06-01

    Education and training in prosthetics and orthotics typically comply with International Society for Prosthetics and Orthotics standards based on three categories of prosthetic and orthotic professionals. This scoping study sought to describe the evidence base available to answer the question, How are prosthetic and orthotic services influenced by the training of staff providing them? Scoping review. A structured search of the peer-reviewed literature catalogued in major electronic databases yielded 3039 papers. Following review of title and abstract, 93 articles were considered relevant. Full-text review reduced this number to 25. Only two articles were identified as providing direct evidence of the effects of training and education on service provision. While both suggested that there was an impact, it is difficult to see how the more specific conclusions of either could be generalised. The other 23 articles provide a useful background to a range of issues including the specification of competencies that training programmes should deliver (3 articles), descriptions of a range of training programmes and the effects of training and education on student knowledge and skills. Although it is considered axiomatic, the service quality is dependent on practitioner education and training. There is insufficient evidence to establish whether levels of training and education in prosthetics and orthotics have an effect on the quality of prosthetic and orthotic services. Clinical relevance There is very little evidence about the effects of training and education of prosthetists and orthotists on service quality. While this is a somewhat negative finding, we feel that it is important to bring this to the attention of the prosthetics and orthotics community.

  11. Pre-operative Asymptomatic Bacteriuria: A Risk Factor For Prosthetic Joint Infection?

    PubMed

    Weale, R; El-Bakri, F; Saeed, Kordo

    2018-04-13

    Infection is a rare complication following implantation of prosthetic material into a joint. The impact of asymptomatic bacteriuria (ASB) before elective operations and the subsequent risk of prosthetic joint infection (PJI) are not well understood. • Assess the prevalence of ASB amongst patients undergoing total arthroplasty of the hip and knee. • Determine the rates of PJI diagnosed within two years of the arthroplasty and if ASB is an independent risk factor for developing PJI. Patients who had total/unicondylar knee or total hip arthroplasty were retrospectively reviewed over a five-year period. Pre-operative urine samples within one year of surgery were analysed and those with ASB identified. Primary outcome was prosthetic joint infection (PJI) within the first postoperative year. 5542 patients were included. 4368 had a pre-operative urine culture recorded. The prevalence of ASB was 140 of 4368 (3.2%). The overall PJI rate was 56 of 5542 (1.01%). Of those with a PJI, 33 had a pre-operative urine sample recorded. The infection rate in the ASB group was 5% (7 of 140), in the no-ASB group it was 0.61% (26 of 4228) and in the group without a urine sample it was 1.96% (23 of 1174) (p value <0.001). The ASB isolate was the same microorganism as the PJI isolate in only one of the seven cases. The association between ASB and PJI is statistically significant, but the urine isolates did not relate to the isolates in the prosthetic joint, suggestive the relationship is unlikely causal. Copyright © 2018. Published by Elsevier Ltd.

  12. Prosthesis use in adult acquired major upper-limb amputees: patterns of wear, prosthetic skills and the actual use of prostheses in activities of daily life.

    PubMed

    Østlie, Kristin; Lesjø, Ingrid Marie; Franklin, Rosemary Joy; Garfelt, Beate; Skjeldal, Ola Hunsbeth; Magnus, Per

    2012-11-01

    To describe patterns of prosthesis wear and perceived prosthetic usefulness in adult acquired upper-limb amputees (ULAs). To describe prosthetic skills in activities of daily life (ADL) and the actual use of prostheses in the performance of ADL tasks. To estimate the influence of prosthetic skills on actual prosthesis use and the influence of background factors on prosthetic skills and actual prosthesis use. Cross-sectional study analysing population-based questionnaire data (n = 224) and data from interviews and clinical testing in a referred/convenience sample of prosthesis-wearing ULAs (n = 50). Effects were analysed using linear regression. 80.8% wore prostheses. 90.3% reported their most worn prosthesis as useful. Prosthetic usefulness profiles varied with prosthetic type. Despite demonstrating good prosthetic skills, the amputees reported actual prosthesis use in only about half of the ADL tasks performed in everyday life. In unilateral amputees, increased actual use was associated with sufficient prosthetic training and with the use of myoelectric vs cosmetic prostheses, regardless of amputation level. Prosthetic skills did not affect actual prosthesis use. No background factors showed significant effect on prosthetic skills. Most major ULAs wear prostheses. Individualised prosthetic training and fitting of myoelectric rather than passive prostheses may increase actual prosthesis use in ADL.

  13. Influence of Different Screw Torque Levels on the Biomechanical Behavior of Tapered Prosthetic Abutments.

    PubMed

    Herbst, Paulo Eduardo; de Carvalho, Eduardo Bortolas; Salatti, Rafael C; Valgas, Laiz; Tiossi, Rodrigo

    To study the force used for tightening tapered one-piece prosthetic abutments and their influence on the removal torque value and stress level of the prosthetic abutment after cyclic loading. Fourteen implants and prosthetic abutments were divided into two groups (n = 7): G1, 20 Ncm; and G2, 32 Ncm (manufacturer recommended). A 20-mm T-shaped horizontal bar was adapted to the abutments. A 12-Hz cyclic loading was applied to the specimens in an electrodynamic testing system with the maximum number of cycles set to 10 6 . Specimens were inclined by 15 degrees from the vertical axis, and a 5-mm off-center vertical load was applied to generate a combination of bending and torquing moments on the tapered connections. Progressive loads (from 164.85 to 362.85 N) were applied when the previous sample survived 10 6 cycles. The paired t test compared the screw removal torque with the initial tightening torque for each group (α = .05). A finite element analysis (FEA) of the mechanical testing analyzed the regions of stress concentration. No specimens failed after 10 6 cyclic loadings. The mean screw removal torque for both groups was similar to the initial abutment torque value applied for each group (G1, 20.36 ± 8.73 Ncm; and G2, 35.61 ± 6.99 Ncm) (P > .05). FEA showed similar stress behavior for both groups in the study despite the different simulated screw preloads (G1: 200 N; G2: 320 N). The coronal region of the implant body presented the highest strain values in both groups. Tightening tapered one-piece prosthetic abutments at 20 and 32 Ncm maintains a stable connection after cyclic loading. The stresses generated by the different tightening forces during cyclic loading are highest at the coronal level of the connection.

  14. Good quality of life outcomes after treatment of prosthetic joint infection with debridement and prosthesis retention.

    PubMed

    Aboltins, Craig; Dowsey, Michelle; Peel, Trish; Lim, Wen K; Choong, Peter

    2016-05-01

    Patients treated for early prosthetic joint infection (PJI) with surgical debridement and prosthesis retention have a rate of successful infection eradication that is similar to patients treated with the traditional approach of prosthesis exchange. It is therefore important to consider other outcomes after prosthetic joint infection treatment that may influence management decisions, such as quality of life (QOL). Our aim was to describe infection cure rates and quality of life for patients with prosthetic joint infection treated with debridement and prosthesis retention and to determine if treatment with this approach was a risk factor for poor quality of life outcomes. Prospectively collected pre and post-arthroplasty data were available for 2,134 patients, of which PJI occurred in 41. For patients treated for prosthetic joint infection, the 2-year survival free of treatment failure was 87% (95%CI 84-89). Prosthetic joint infection cases treated with debridement and retention had a similar improvement from pre-arthroplasty to 12-months post-arthroplasty as patients without PJI in QOL according to the SF-12 survey. Prosthetic joint infection treated with debridement and retention was not a risk factor for poor quality of life on univariate or multivariate analysis. Prosthetic joint infection treated with debridement and prosthesis retention results in good cure rates and quality of life. Further studies are required that directly compare quality of life for different surgical approaches for prosthetic joint infection to better inform management decisions. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:898-902, 2016. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  15. Prosthetic vascular graft infection and prosthetic joint infection caused by Pseudomonas stutzeri.

    PubMed

    Bonares, Michael J; Vaisman, Alon; Sharkawy, Abdu

    2016-01-01

    Pseudomonas stutzeri is infrequently isolated from clinical specimens, and if isolated, more likely represents colonization or contamination rather than infection. Despite this, there are dozens of case reports which describe clinically significant P. stutzeri infections at variable sites. A 69-year-old man had a P. stutzeri infection of a prosthetic vascular graft infection, which he received in Panama City. He was successfully treated with a single antipseudomonal agent for 6 weeks and the removal of the infected vascular graft. A 70-year-old man had a P. stutzeri infection of a prosthetic joint, which was successfully treated with a single anti-pseudomonal agent for 6 weeks. There is only one other documented case of a prosthetic vascular graft infection secondary to P. stutzeri . There are 5 documented cases of P. stutzeri prosthetic joint infections. The previous cases were treated with antibiotics and variably, source control with the removal of prosthetic material. Most cases of P. stutzeri infection are due to exposure in health care settings. Immunocompromised states such as HIV or hematological and solid tumor malignancies are risk factors for P. stutzeri infection. Infections caused by P. stutzeri are far less frequent and less fatal than those caused by P. aeruginosa. The etiology of a P. stutzeri infection could be exposure to soil and water, but also contaminated material in the health care setting or an immunocompromised state. Iatrogenic infections that are secondary to health care tourism are a potential cause of fever in the returned traveler.

  16. Influence of psychological factors on the acceptance of complete dentures.

    PubMed

    al Quran, F; Clifford, T; Cooper, C; Lamey, P J

    2001-07-01

    To assess the influence of psychological factors on the acceptance of complete dentures in a population wearing dentures judged to be clinically satisfactory. Subjects were asked to complete personality profiles and also to rate their dentures using a denture satisfaction questionnaire. The survey was conducted in the prosthetics clinic of a teaching hospital. Patients were selected from those who had new complete dentures constructed in the department within the previous two years. The personality inventory was a self-administered questionnaire comprising 240 items covering the five domains of personality. Denture satisfaction was scored on a nine item scale with four Likert type responses to each. A group of 16% consistently complained about their dentures. Statistical analysis showed that personality factors especially Neuroticism had a significant relationship with denture satisfaction. Psychological factors significantly influence denture satisfaction and profiles may provide useful in predicting potential difficult denture wearers.

  17. Advanced upper limb prosthetic devices: implications for upper limb prosthetic rehabilitation.

    PubMed

    Resnik, Linda; Meucci, Marissa R; Lieberman-Klinger, Shana; Fantini, Christopher; Kelty, Debra L; Disla, Roxanne; Sasson, Nicole

    2012-04-01

    The number of catastrophic injuries caused by improvised explosive devices in the Afghanistan and Iraq Wars has increased public, legislative, and research attention to upper limb amputation. The Department of Veterans Affairs (VA) has partnered with the Defense Advanced Research Projects Agency and DEKA Integrated Solutions to optimize the function of an advanced prosthetic arm system that will enable greater independence and function. In this special communication, we examine current practices in prosthetic rehabilitation including trends in adoption and use of prosthetic devices, financial considerations, and the role of rehabilitation team members in light of our experiences with a prototype advanced upper limb prosthesis during a VA study to optimize the device. We discuss key challenges in the adoption of advanced prosthetic technology and make recommendations for service provision and use of advanced upper limb prosthetics. Rates of prosthetic rejection are high among upper limb amputees. However, these rates may be reduced with sufficient training by a highly specialized, multidisciplinary team of clinicians, and a focus on patient education and empowerment throughout the rehabilitation process. There are significant challenges emerging that are unique to implementing the use of advanced upper limb prosthetic technology, and a lack of evidence to establish clinical guidelines regarding prosthetic prescription and treatment. Finally, we make recommendations for future research to aid in the identification of best practices and development of policy decisions regarding insurance coverage of prosthetic rehabilitation. Copyright © 2012 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  18. Learning prosthetic vision: a virtual-reality study.

    PubMed

    Chen, Spencer C; Hallum, Luke E; Lovell, Nigel H; Suaning, Gregg J

    2005-09-01

    Acceptance of prosthetic vision will be heavily dependent on the ability of recipients to form useful information from such vision. Training strategies to accelerate learning and maximize visual comprehension would need to be designed in the light of the factors affecting human learning under prosthetic vision. Some of these potential factors were examined in a visual acuity study using the Landolt C optotype under virtual-reality simulation of prosthetic vision. Fifteen normally sighted subjects were tested for 10-20 sessions. Potential learning factors were tested at p < 0.05 with regression models. Learning was most evident across-sessions, though 17% of sessions did express significant within-session trends. Learning was highly concentrated toward a critical range of optotype sizes, and subjects were less capable in identifying the closed optotype (a Landolt C with no gap, forming a closed annulus). Training for implant recipients should target these critical sizes and the closed optotype to extend the limit of visual comprehension. Although there was no evidence that image processing affected overall learning, subjects showed varying personal preferences.

  19. Rothia mucilaginosa Prosthetic Device Infections: a Case of Prosthetic Valve Endocarditis

    PubMed Central

    Tokarczyk, Mindy J.; Jungkind, Donald; DeSimone, Joseph A.

    2013-01-01

    Rothia mucilaginosa is increasingly recognized as an emerging opportunistic pathogen associated with prosthetic device infections. Infective endocarditis is one of the most common clinical presentations. We report a case of R. mucilaginosa prosthetic valve endocarditis and review the literature of prosthetic device infections caused by this organism. PMID:23467598

  20. Oral health-related quality of life in complete denture wearers depending on their socio-demographic background, prosthetic-related factors and clinical condition

    PubMed Central

    Perea, Carmen; Suárez-García, María J.; Del Río, Jaime; Torres-Lagares, Daniel; Montero, Javier

    2013-01-01

    Objectives: To investigate the differences in impact on oral health-related quality of life (OHRQoL) among complete denture wearers depending on their socio-demographic characteristics, prosthetic-related factors and oral status. Study Design: 51 patients aged 50-90 years treated, from 2005 to 2010, with at least one complete denture at the Department of Buccofacial Prostheses of the Complutense University (Madrid) were enrolled in this cross-sectional study. All of the participants answered the Oral Health Impact Profile (OHIP-14sp) questionnaire. The additive scoring method was used. The prevalence of impacts was calculated by using the occasional threshold (OHIP-14sp score≥2). Socio-demographic and prosthetic-related variables were gathered. Patients underwent clinical examination to assess their oral condition. Descriptive probes and Chi-Square tests were run (p≤0.05). Results: The predominant participants’ profile was that of a man with a mean age of 69 years wearing complete dentures in both the maxilla and the mandible. The prevalence of impact was 23.5%, showing an average score of 19±9.8. The most affected domains were “functional limitation” and “physical pain”, followed by “physical disability”. Minor impacts were recorded for the psychological and social subscales (“psychological discomfort”, “psychological disability”, “social disability” and “handicap”). The prosthesis’ location significantly influenced the overall patient satisfaction, the lower dentures being the less comfortable. Having a complete removable denture as antagonist significantly hampered the patient satisfaction. Patients without prosthetic stomatitis and those who need repairing or changing their prostheses, recorded significantly higher OHIP-14sp total scores. Conclusions: The use of conventional complete dentures brings negative impacts in the OHRQoL of elderly patients, mainly in case of lower prostheses that required reparation or substitution

  1. Threshold concepts in prosthetics.

    PubMed

    Hill, Sophie

    2017-12-01

    Curriculum documents identify key concepts within learning prosthetics. Threshold concepts provide an alternative way of viewing the curriculum, focussing on the ways of thinking and practicing within prosthetics. Threshold concepts can be described as an opening to a different way of viewing a concept. This article forms part of a larger study exploring what students and staff experience as difficult in learning about prosthetics. To explore possible threshold concepts within prosthetics. Qualitative, interpretative phenomenological analysis. Data from 18 students and 8 staff at two universities with undergraduate prosthetics and orthotics programmes were generated through interviews and questionnaires. The data were analysed using an interpretative phenomenological analysis approach. Three possible threshold concepts arose from the data: 'how we walk', 'learning to talk' and 'considering the person'. Three potential threshold concepts in prosthetics are suggested with possible implications for prosthetics education. These possible threshold concepts involve changes in both conceptual and ontological knowledge, integrating into the persona of the individual. This integration occurs through the development of memories associated with procedural concepts that combine with disciplinary concepts. Considering the prosthetics curriculum through the lens of threshold concepts enables a focus on how students learn to become prosthetists. Clinical relevance This study provides new insights into how prosthetists learn. This has implications for curriculum design in prosthetics education.

  2. Second-site prosthetic joint infection in patients with multiple prosthetic joints.

    PubMed

    Clesham, Kevin; Hughes, Andrew J; O' hEireamhoin, Sven; Fleming, Catherine; Murphy, Colin G

    2018-04-10

    Prosthetic joint infections (PJIs) are among the most serious complications in arthroplasty. A second-site PJI in patients with multiple prosthetic joints increases morbidity, with many requiring further revision procedures. We aimed to establish why some patients with multiple joints develop second-site infections. Our institution's arthroplasty database was reviewed from 2004 to 2017. All PJIs were identified, and all patients with more than one prosthetic joint in situ were included. We recorded risk factors, causative organisms, number of procedures and length of stay. Forty-four patients meeting the criteria were identified. Four patients (9.1%) developed second-site infection. Eight patients (18.2%) developed re-infection of the primary PJI. Positive MRSA carrier status and PJI of a total knee replacement were associated with an increased risk of a second episode of infection. Patients who developed further infection had more frequent admission and longer lengths of stay than isolated PJIs. Higher morbidity and use of hospital resources are associated with this cohort of patients. PJIs in total knee replacements and positive MRSA status are associated with higher rates of second infection. Identifying this vulnerable cohort of patients at an early stage is critical to ensure measures are taken to reduce the risks of further infection.

  3. Strength evaluation of prosthetic check sockets, copolymer sockets, and definitive laminated sockets.

    PubMed

    Gerschutz, Maria J; Haynes, Michael L; Nixon, Derek; Colvin, James M

    2012-01-01

    A prosthesis encounters loading through forces and torques exerted by the person with amputation. International Organization for Standardization (ISO) standard 10328 was designed to test most lower-limb prosthetic components. However, this standard does not include prosthetic sockets. We measured static failure loads of prosthetic sockets using a modified ISO 10328 and then compared them with the criteria set by this standard for other components. Check socket (CS) strengths were influenced by thickness, material choice, and fabrication method. Copolymer socket (CP) strengths depended on thickness and fabrication methods. A majority of the CSs and all of the CPs failed to pass the ISO 10328 ductile loading criterion. In contrast, the strengths of definitive laminated sockets (DLs) were influenced more by construction material and technique. A majority of the DLs failed to pass the ISO 10328 brittle loading criterion. Analyzing prosthetic sockets from a variety of facilities demonstrated that socket performance varies considerably between and within facilities. The results from this article provide a foundation for understanding the quality of prosthetic sockets, some insight into possible routes for improving the current care delivered to patients, and a comparative basis for future technology.

  4. Influence of parafunctional loading and prosthetic connection on stress distribution: a 3D finite element analysis.

    PubMed

    Torcato, Leonardo Bueno; Pellizzer, Eduardo Piza; Verri, Fellippo Ramos; Falcón-Antenucci, Rosse Mary; Santiago Júnior, Joel Ferreira; de Faria Almeida, Daniel Augusto

    2015-11-01

    Clinicians should consider parafunctional occlusal load when planning treatment. Prosthetic connections can reduce the stress distribution on an implant-supported prosthesis. The purpose of this 3-dimensional finite element study was to assess the influence of parafunctional loading and prosthetic connections on stress distribution. Computer-aided design software was used to construct 3 models. Each model was composed of a bone and an implant (external hexagon, internal hexagon, or Morse taper) with a crown. Finite element analysis software was used to generate the finite element mesh and establish the loading and boundary conditions. A normal force (200-N axial load and 100-N oblique load) and parafunctional force (1000-N axial and 500-N oblique load) were applied. Results were visualized as the maximum principal stress. Three-way analysis of variance and Tukey test were performed, and the percentage of contribution of each variable to the stress concentration was calculated from sum-of squares-analysis. Stress was concentrated around the implant at the cortical bone, and models with the external hexagonal implant showed the highest stresses (P<.001). Oblique loads produced high tensile stress concentrations on the site opposite the load direction. Internal connection implants presented the most favorable biomechanical situation, whereas the least favorable situation was the biomechanical behavior of external connection implants. Parafunctional loading increased the magnitude of stress by 3 to 4 times. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  5. [Overlay prosthetic solution in subtotal edentation treatment].

    PubMed

    Tatarciuc, M; Ursache, M; Grădinaru, I

    2001-01-01

    The preservation of the natural dental roots represents a big advantage for the overdenture prosthetic appliances. The realization of an overdenture needs a perfect correlation of all the clinical and technological factors, in all the prosthetics steps. Another important aspect is represented by the possibility of a correct treatment of the remaining roots. The remaining roots will be correctly endodontically treated. The root section will be prepared with two inclines bucally and orally located. A metallic cup will cover the root section. On the inner surface of the overdenture the dental technician will realize specific preparations corresponding to this cups. This kind of prosthetic treatment is indicated only for patients with a very good oral hygiene and a good general health.

  6. Analysis of colour stability of selected provisional prosthetic materials: an in vitro study.

    PubMed

    Koczorowski, Ryszard; Linkowska-Swidzińska, Kamila; Gedrange, Tomasz; Swidziński, Teodor

    2009-08-01

    Prosthetic restorative materials (that are) used for temporary fixed dentures tend to exhibit variable discolouration over several weeks of use. The aim of this study was to perform a spectrophotometric analysis of the influence of selected discolouring factors on the colour stability of provisional prosthetic materials in vitro. In the study, the following prosthetic materials for short-term use in the oral cavity were evaluated: Luxatemp, Structur 2S.C., Protemp II, Zhermacryl STC and Dentalon Plus. Samples of these materials were immersed in coffee, tea and dark fruit juice for 60 h at different pH values. Colour was evaluated by determining the monochromatic coefficients of light reflected by the samples, using a spectrophotometric method. Results received in artificial light (illuminant A) were compared with those obtained in daylight (illuminant D65). Changes in colour and its parameters according to the CIE L*a*b* system were analysed. The analysis (of the colour and colour parameters) of the tested materials in two types of light showed that Structur displayed the greatest tendency to discolouration and that the least tendency to discolouration was exhibited by Dentalon Plus. The fact that colour parameters obtained in two types of light were not identical suggests that changes in the colour of the same material may be perceived differently, depending on the illuminant. Provisional prosthetic materials show variable colour stability under different conditions in the oral cavity. The colour of prosthetic materials may be perceived differently, depending on the illuminant and the effect of the environment in which they are used.

  7. Identifying the values and preferences of prosthetic users: a case study series using the repertory grid technique.

    PubMed

    Schaffalitzky, Elisabeth; NiMhurchadha, Sinead; Gallagher, Pamela; Hofkamp, Susan; MacLachlan, Malcolm; Wegener, Stephen T

    2009-06-01

    The matching of prosthetic devices to the needs of the individual is a challenge for providers and patients. The aims of this study are to explore the values and preferences that prosthetic users have of their prosthetic devices; to investigate users' perceptions of alternative prosthetic options and to demonstrate a novel method for exploring the values and preferences of prosthetic users. This study describes four case studies of upper limb and lower limb high tech and conventional prosthetic users. Participants were interviewed using the repertory grid technique (RGT), a qualitative technique to explore individual values and preferences regarding specific choices and events. The participants generated distinctive patterns of personal constructs and ratings regarding prosthetic use and different prosthetic options available. The RGT produced a unique profile of preferences regarding prosthetic technologies for each participant. User choice is an important factor when matching prosthetic technology to the user. The consumer's values regarding different prosthetic options are likely to be a critical factor in prosthetic acceptance and ultimate quality of life. The RGT offers a structured method of exploring these attitudes and values without imposing researcher or practitioner bias and identifies personalized dimensions for providers and users to evaluate the individuals' preferences in prosthetic technology.

  8. Quality of life after maxillectomy and prosthetic obturator rehabilitation.

    PubMed

    Chigurupati, Radhika; Aloor, Neelam; Salas, Richard; Schmidt, Brian L

    2013-08-01

    Surgical resection of midface neoplasms and subsequent reconstruction have been shown to have significant negative effects on quality of life (QOL). The purpose of this pilot study was to assess individuals' health-related QOL after maxillectomy and reconstruction with a prosthetic obturator. The QOL of 25 of 43 patients who underwent maxillectomy and prosthetic obturator reconstruction at the University of California-San Francisco was assessed using 3 questionnaires: University of Washington Quality of Life version 4 (UWQOL), Obturator Functioning Scale (OFS), and Mental Health Inventory (MHI). The response rate to the QOL questionnaires was 92% (23 of 25 patients). Time elapsed from maxillectomy and prosthetic obturator reconstruction to the QOL survey response ranged from 0.3 to 6.6 years (mean, 2.7 years; standard deviation [SD], 1.9 years). The post-treatment mean QOL scores were 77.3 (SD, 13.6) for UWQOL, 72.0 (SD, 12.6) for OFS, and 4.5 (SD, 0.9) for Mental Health Inventory. Individuals who received adjuvant radiation scored lower for speech and appearance (OFS, P = .05, P = .03, respectively) as well as for saliva and overall QOL (UWQOL, P = .02, P = .08, respectively). There was a strong correlation between QOL scores in OFS and UWQOL questionnaires (r = 0.78, P < .001). The results of this pilot study suggest that postoperative radiation therapy was the strongest variable affecting QOL in patients with maxillectomy and prosthetic obturator reconstruction. There is further need for a multicenter trial with a larger sample to identify how factors affecting QOL of patients after maxillectomy might influence the choice of reconstruction. Copyright © 2013 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  9. Microprocessor prosthetic knees.

    PubMed

    Berry, Dale

    2006-02-01

    This article traces the development of microprocessor prosthetic knees from early research in the 1970s to the present. Read about how microprocessor knees work, functional options, patient selection, and the future of this prosthetic.

  10. Bruxism and prosthetic treatment: a critical review.

    PubMed

    Johansson, Anders; Omar, Ridwaan; Carlsson, Gunnar E

    2011-07-01

    Based on the findings from available research on bruxism and prosthetic treatment published in the dental literature, an attempt was made to draw conclusions about the existence of a possible relationship between the two, and its clinical relevance. MEDLINE/PubMed searches were conducted using the terms 'bruxism' and 'prosthetic treatment', as well as combinations of these and related terms. The few studies judged to be relevant were critically reviewed, in addition to papers found during an additional manual search of reference lists within selected articles. Bruxism is a common parafunctional habit, occurring both during sleep and wakefulness. Usually it causes few serious effects, but can do so in some patients. The etiology is multifactorial. There is no known treatment to stop bruxism, including prosthetic treatment. The role of bruxism in the process of tooth wear is unclear, but it is not considered a major cause. As informed by the present critical review, the relationship between bruxism and prosthetic treatment is one that relates mainly to the effect of the former on the latter. Bruxism may be included among the risk factors, and is associated with increased mechanical and/or technical complications in prosthodontic rehabilitation, although it seems not to affect implant survival. When prosthetic intervention is indicated in a patient with bruxism, efforts should be made to reduce the effects of likely heavy occlusal loading on all the components that contribute to prosthetic structural integrity. Failure to do so may indicate earlier failure than is the norm. Copyright © 2011 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  11. Prosthetic implant treatment of the edentulous maxilla with overdenture.

    PubMed

    Inversini, M

    2006-10-01

    The literature concerning the success of prosthetic implant treatment with maxillary overdenture is reviewed, and variables affecting treatment from the implant and prosthetic standpoint are analysed. Guidelines for the fabrication of maxillary overimplants comparable to those for mandibular overimplants are still lacking, as are evidence-based prosthetic design concepts. Individual methods and techniques have been described, but evaluation standards for the outcome of maxillary prosthetic-implant treatment are lacking or individually interpreted. The biomechanics involved in the proposed system are described, together with the advantages of telescopic crowns for the retention of removable partial prosthesis supported by maxillary implants. The positive influence, in terms of long-term prognosis, of the perio-protective design of removable partial prostheses supported by maxillary overimplants is also discussed. The proposed system not only provides stability, support and retention for removable partial prostheses supported by maxillary implants, but also enables implant survival rates to be improved, both for biomechanical reasons and due to improved oral hygiene. The simplification of fabrication procedures, repair, rebasing and re-operating also reduce the cost of follow-up and improve the cost/benefit ratio. However, additional studies are needed to clarify the number and most appropriate distribution of implants, as well as the most favourable prosthetic designs for maxillary overimplants.

  12. Viability of Controlling Prosthetic Hand Utilizing Electroencephalograph (EEG) Dataset Signal

    NASA Astrophysics Data System (ADS)

    Miskon, Azizi; A/L Thanakodi, Suresh; Raihan Mazlan, Mohd; Mohd Haziq Azhar, Satria; Nooraya Mohd Tawil, Siti

    2016-11-01

    This project presents the development of an artificial hand controlled by Electroencephalograph (EEG) signal datasets for the prosthetic application. The EEG signal datasets were used as to improvise the way to control the prosthetic hand compared to the Electromyograph (EMG). The EMG has disadvantages to a person, who has not used the muscle for a long time and also to person with degenerative issues due to age factor. Thus, the EEG datasets found to be an alternative for EMG. The datasets used in this work were taken from Brain Computer Interface (BCI) Project. The datasets were already classified for open, close and combined movement operations. It served the purpose as an input to control the prosthetic hand by using an Interface system between Microsoft Visual Studio and Arduino. The obtained results reveal the prosthetic hand to be more efficient and faster in response to the EEG datasets with an additional LiPo (Lithium Polymer) battery attached to the prosthetic. Some limitations were also identified in terms of the hand movements, weight of the prosthetic, and the suggestions to improve were concluded in this paper. Overall, the objective of this paper were achieved when the prosthetic hand found to be feasible in operation utilizing the EEG datasets.

  13. Occlusion properties of prosthetic contact lenses for the treatment of amblyopia.

    PubMed

    Collins, Randall S; McChesney, Megan E; McCluer, Craig A; Schatz, Martha P

    2008-12-01

    The efficacy of opaque contact lenses as occlusion therapy for amblyopia has been established in the literature. Prosthetic contact lenses use similar tints to improve cosmesis in scarred or deformed eyes and may be an alternative in occlusion therapy. To test this idea, we determined the degree of vision penalization elicited by prosthetic contact lenses and their effect on peripheral fusion. We tested 19 CIBA Vision DuraSoft 3 Prosthetic soft contact lenses with varying iris prints, underprints, and opaque pupil sizes in 10 volunteers with best-corrected Snellen distance visual acuity of 20/20 or better in each eye. Snellen visual acuity and peripheral fusion using the Worth 4-Dot test at near were measured on each subject wearing each of the 19 lenses. Results were analyzed with 3-factor analysis of variance. Mean visual acuity through the various lenses ranged from 20/79 to 20/620. Eight lenses allowed preservation of peripheral fusion in 50% or more of the subjects tested. Iris print pattern and opaque pupil size were significant factors in determining visual acuity (p < 0.05). Sufficient vision penalization can be achieved to make occlusion with prosthetic contact lenses a viable therapy for amblyopia. The degree of penalization can be varied and different iris print patterns and pupil sizes, using peripheral fusion, can be preserved with some lenses. Prosthetic contact lenses can be more cosmetically appealing and more tolerable than other amblyopia treatment modalities. These factors may improve compliance in occlusion therapy.

  14. Fused Filament Fabrication of Prosthetic Components for Trans-Humeral Upper Limb Prosthetics

    NASA Astrophysics Data System (ADS)

    Lathers, Steven M.

    Presented below is the design and fabrication of prosthetic components consisting of an attachment, tactile sensing, and actuator systems with Fused Filament Fabrication (FFF) technique. The attachment system is a thermoplastic osseointegrated upper limb prosthesis for average adult trans-humeral amputation with mechanical properties greater than upper limb skeletal bone. The prosthetic designed has: a one-step surgical process, large cavities for bone tissue ingrowth, uses a material that has an elastic modulus less than skeletal bone, and can be fabricated on one system. FFF osseointegration screw is an improvement upon the current two-part osseointegrated prosthetics that are composed of a fixture and abutment. The current prosthetic design requires two invasive surgeries for implantation and are made of titanium, which has an elastic modulus greater than bone. An elastic modulus greater than bone causes stress shielding and overtime can cause loosening of the prosthetic. The tactile sensor is a thermoplastic piezo-resistive sensor for daily activities for a prosthetic's feedback system. The tactile sensor is manufactured from a low elastic modulus composite comprising of a compressible thermoplastic elastomer and conductive carbon. Carbon is in graphite form and added in high filler ratios. The printed sensors were compared to sensors that were fabricated in a gravity mold to highlight the difference in FFF sensors to molded sensors. The 3D printed tactile sensor has a thickness and feel similar to human skin, has a simple fabrication technique, can detect forces needed for daily activities, and can be manufactured in to user specific geometries. Lastly, a biomimicking skeletal muscle actuator for prosthetics was developed. The actuator developed is manufactured with Fuse Filament Fabrication using a shape memory polymer composite that has non-linear contractile and passive forces, contractile forces and strains comparable to mammalian skeletal muscle, reaction

  15. Myoelectric control of prosthetic hands: state-of-the-art review

    PubMed Central

    Geethanjali, Purushothaman

    2016-01-01

    Myoelectric signals (MES) have been used in various applications, in particular, for identification of user intention to potentially control assistive devices for amputees, orthotic devices, and exoskeleton in order to augment capability of the user. MES are also used to estimate force and, hence, torque to actuate the assistive device. The application of MES is not limited to assistive devices, and they also find potential applications in teleoperation of robots, haptic devices, virtual reality, and so on. The myoelectric control-based prosthetic hand aids to restore activities of daily living of amputees in order to improve the self-esteem of the user. All myoelectric control-based prosthetic hands may not have similar operations and exhibit variation in sensing input, deciphering the signals, and actuating prosthetic hand. Researchers are focusing on improving the functionality of prosthetic hand in order to suit the user requirement with the different operating features. The myoelectric control differs in operation to accommodate various external factors. This article reviews the state of the art of myoelectric prosthetic hand, giving description of each control strategy. PMID:27555799

  16. Virtual Preoperative Planning and Intraoperative Navigation in Facial Prosthetic Reconstruction: A Technical Note.

    PubMed

    Verma, Suzanne; Gonzalez, Marianela; Schow, Sterling R; Triplett, R Gilbert

    This technical protocol outlines the use of computer-assisted image-guided technology for the preoperative planning and intraoperative procedures involved in implant-retained facial prosthetic treatment. A contributing factor for a successful prosthetic restoration is accurate preoperative planning to identify prosthetically driven implant locations that maximize bone contact and enhance cosmetic outcomes. Navigational systems virtually transfer precise digital planning into the operative field for placing implants to support prosthetic restorations. In this protocol, there is no need to construct a physical, and sometimes inaccurate, surgical guide. The report addresses treatment workflow, radiologic data specifications, and special considerations in data acquisition, virtual preoperative planning, and intraoperative navigation for the prosthetic reconstruction of unilateral, bilateral, and midface defects. Utilization of this protocol for the planning and surgical placement of craniofacial bone-anchored implants allows positioning of implants to be prosthetically driven, accurate, precise, and efficient, and leads to a more predictable treatment outcome.

  17. Advanced Prosthetic Gait Training Tool

    DTIC Science & Technology

    2014-10-01

    AWARD NUMBER: W81XWH-10-1-0870 TITLE: Advanced Prosthetic Gait Training Tool...October 2014 2. REPORT TYPE Annual Report 3. DATES COVERED 20 Sep 2013 to 19 Sep 2014 4. TITLE AND SUBTITLE Advanced Prosthetic Gait Training...produce a computer-based Advanced Prosthetic Gait Training Tool to aid in the training of clinicians at military treatment facilities providing care

  18. AB0 blood types: impact on development of prosthetic mechanical valve thrombosis

    PubMed Central

    Astarcıoğlu, Mehmet Ali; Kalçık, Macit; Yesin, Mahmut; Gürsoy, Mustafa Ozan; Şen, Taner; Karakoyun, Süleyman; Gündüz, Sabahattin; Özkan, Mehmet

    2016-01-01

    Objective: The non-O alleles of the ABO genotype have been associated with an increased risk of thrombosis. We aimed to assess the association between blood group status and prosthetic valve thrombosis. Methods: The association between AB0 blood group status and prosthetic valve thrombosis was assessed in this retrospective study. Transesophageal echocardiography was performed in 149 patients with a diagnosis of prosthetic valve thrombosis and in 192 control subjects. Results: Non-0 blood group type (p<0.001), presence of NYHA class III-IV status (p<0.001), and central nervous system (p<0.001) and non-central nervous system (p<0.001) emboli were significantly more prevalent in prosthetic valve thrombosis patients than in the control subjects. The incidence of ineffective anticoagulation was higher in patients with prosthetic valve thrombosis than in controls (p<0.001), as was the presence of moderate to severe left atrial spontaneous echo contrast (p<0.001). The non-0 blood prosthetic valve thrombosis subgroup had a higher incidence of obstructive thrombi and central nervous system thrombotic events than having 0 blood prosthetic valve thrombosis subgroup. Non-0 blood group, ineffective anticoagulation, left atrial spontaneous echo contrast, and a poor NYHA functional capacity were identified to be the predictors of prosthetic valve thrombosis. Conclusion: Our data demonstrate that patients with non-0 compared with 0 blood groups have higher incidence of prosthetic valve thrombosis and central nervous system embolism and similar rates of non-central nervous system embolism at presentation compared with 0 blood group type. Thus, non-O blood group may be a risk factor that may be prone to the development of prosthetic valve thrombosis in patients with prosthetic heart valves. PMID:27488753

  19. Progressive upper limb prosthetics.

    PubMed

    Lake, Chris; Dodson, Robert

    2006-02-01

    The field of upper extremity prosthetics is a constantly changing arena as researchers and prosthetists strive to bridge the gap between prosthetic reality and upper limb physiology. With the further development of implantable neurologic sensing devices and targeted muscle innervation (discussed elsewhere in this issue), the challenge of limited input to control vast outputs promises to become a historical footnote in the future annals of upper limb prosthetics. Soon multidextrous terminal devices, such as that found in the iLimb system(Touch EMAS, Inc., Edinburgh, UK), will be a clinical reality (Fig. 22). Successful prosthetic care depends on good communication and cooperation among the surgeon, the amputee, the rehabilitation team, and the scientists harnessing the power of technology to solve real-life challenges. If the progress to date is any indication, amputees of the future will find their dreams limited only by their imagination.

  20. Finite element analysis of the contact interface between trans-femoral stump and prosthetic socket.

    PubMed

    Zhang, Linlin; Zhu, Ming; Shen, Ling; Zheng, Feng

    2013-01-01

    Transfemoral amputees need prosthetic devices after amputation surgery, and the interface pressure between the residual limb and prosthetic socket has a significant effect on an amputee's satisfaction and comfort. The purpose of this study was to build a nonlinear finite element model to investigate the interface pressure between the above-knee residual limb and its prosthetic socket. The model was three-dimensional (3D) with consideration of nonlinear boundary conditions. Contact analysis was used to simulate the friction conditions between skin and the socket. The normal stresses up to 80.57 kPa at the distal end of the soft tissue. The longitudinal and circumferential shear stress distributions at the limb-socket interface were also simulated. This study explores the influences of load transfer between trans-femoral residual limb and its prosthetic socket.

  1. A Prosthetic Foot Emulator to Optimize Prescription of Prosthetic Feet in Veterans and Service Members with Leg Amputations

    DTIC Science & Technology

    2017-09-01

    AWARD NUMBER: W81XWH-16-1-0569 TITLE: A Prosthetic Foot Emulator to Optimize Prescription of Prosthetic Feet in Veterans and Service Members...Headquarters Services , Directorate for Information Operations and Reports (0704-0188), 1215 Jefferson Davis Highway, Suite 1204, Arlington, VA 22202- 4302...GRANT NUMBER A Prosthetic Foot Emulator to Optimize Prescription of Prosthetic Feet in Veterans and Service Members with Leg Amputations 5c

  2. Granulicatella adiacens prosthetic hip joint infection after dental treatment.

    PubMed

    Aweid, Osama; Sundararajan, Sabapathy; Teferi, Abraham

    2016-06-01

    Granulicatella adiacens is a Gram-positive bacteria and a normal component of oral flora. It is also found in dental plaques, endodontic abscesses and can rarely cause more serious infections. We describe a prosthetic hip joint infection in an 81-year-old fit and healthy man due to Granulicatella adiacens who underwent a prolonged dental intervention two days earlier without antibiotic prophylaxis. The infection was successfully treated with surgical intervention and a combination of antibiotics. The patient eventually succumbed to severe community-acquired pneumonia two months later. Current guidelines recommend avoidance of antibiotic prophylaxis prior to dental treatment in patients who have no co-morbidities and no prior operation on the index prosthetic joint. This case report indicates that infections of prosthetic joints may be associated with dental procedures even in fit and healthy patients without the recognized risk factors.

  3. Upper Extremity Amputations and Prosthetics

    PubMed Central

    Ovadia, Steven A.; Askari, Morad

    2015-01-01

    Upper extremity amputations are most frequently indicated by severe traumatic injuries. The location of the injury will determine the level of amputation. Preservation of extremity length is often a goal. The amputation site will have important implications on the functional status of the patient and options for prosthetic reconstruction. Advances in amputation techniques and prosthetic reconstructions promote improved quality of life. In this article, the authors review the principles of upper extremity amputation, including techniques, amputation sites, and prosthetic reconstructions. PMID:25685104

  4. Isolated Lactobacillus chronic prosthetic knee infection.

    PubMed

    Bennett, David M; Shekhel, Tatyana; Radelet, Matt; Miller, Michael D

    2014-01-01

    Lactobacillus is a gram-positive rod bacteria found primarily in the gastrointestinal and female genital tracts. Prosthetic infections in implants are being increasingly reported. The authors present a case of a 58-year-old patient with Lactobacillus septic prosthetic knee joint infection. To the authors’ knowledge, this is the first reported case of chronic prosthetic knee infection with isolated Lactobacillus species. Lactobacillus has been most commonly implicated with bacteremia and endocarditis and rarely with pneumonia, meningitis, and endovascular infection, and a vast majority of the cases are reported in immunocompromised patients. In the current case, diabetes mellitus, hepatitis, malnutrition, anemia, and liver failure were comorbid conditions, placing the patient at increased risk of infection. The findings suggest that further case series are necessary to establish the significance of Lactobacillus as an etiologic agent in chronic low-virulence, and potentially vancomycin-resistant, prosthetic joint infection. The need also exists for further research aimed at the risk of prosthetic joint infection with oral intake of certain probiotic foods and supplements. The goal of this case report is to bring to light the potential of this organism to be a cause of subtle chronic prosthetic joint infection.

  5. 21 CFR 870.3945 - Prosthetic heart valve sizer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Prosthetic heart valve sizer. 870.3945 Section 870...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3945 Prosthetic heart valve sizer. (a) Identification. A prosthetic heart valve sizer is a device used to measure the size of the...

  6. 21 CFR 870.3945 - Prosthetic heart valve sizer.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Prosthetic heart valve sizer. 870.3945 Section 870...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3945 Prosthetic heart valve sizer. (a) Identification. A prosthetic heart valve sizer is a device used to measure the size of the...

  7. 21 CFR 870.3945 - Prosthetic heart valve sizer.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Prosthetic heart valve sizer. 870.3945 Section 870...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3945 Prosthetic heart valve sizer. (a) Identification. A prosthetic heart valve sizer is a device used to measure the size of the...

  8. 21 CFR 870.3945 - Prosthetic heart valve sizer.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Prosthetic heart valve sizer. 870.3945 Section 870...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3945 Prosthetic heart valve sizer. (a) Identification. A prosthetic heart valve sizer is a device used to measure the size of the...

  9. 21 CFR 870.3945 - Prosthetic heart valve sizer.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Prosthetic heart valve sizer. 870.3945 Section 870...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3945 Prosthetic heart valve sizer. (a) Identification. A prosthetic heart valve sizer is a device used to measure the size of the...

  10. Future Research Opportunities in Peri-Prosthetic Joint Infection Prevention.

    PubMed

    Berbari, Elie; Segreti, John; Parvizi, Javad; Berríos-Torres, Sandra I

    Peri-prosthetic joint infection (PJI) is a serious complication of prosthetic joint arthroplasty. A better understanding and reversal of modifiable risk factors may lead to a reduction in the incidence of incisional (superficial and deep) and organ/space (e.g., PJI) surgical site infections (SSI). Recently, the Centers for Disease Control and Prevention (CDC) and the Healthcare Infection Control Practices Advisory Committee (HICPAC) published the Guideline for Prevention of Surgical Site Infection. This targeted update applies evidence-based methodology in drafting recommendations for potential strategies to reduce the risk of SSI both across surgical procedures and specifically in prosthetic joint arthroplasty. A panel of PJI content experts identified nine PJI prevention research opportunities based on both evidence gaps identified through the guideline development process (transfusion, immunosuppressive therapy, anticoagulation, orthopedic space suit, and biofilm) and expert opinion (anesthesia, operative room environment, glycemic control, and Staphylococcus aureus nasal screening and decolonization. This article offers a road map for PJI prevention research.

  11. The Prosthetic Influence and Biomechanics on Peri-Implant Strain: a Systematic Literature Review of Finite Element Studies.

    PubMed

    Maminskas, Julius; Puisys, Algirdas; Kuoppala, Ritva; Raustia, Aune; Juodzbalys, Gintaras

    2016-01-01

    To systematically review risks of mechanical impact on peri-implant strain and prosthetic influence on stability across finite element studies. An online literature search was performed on MEDLINE and EMBASE databases published between 2011 and 2016. Following keywords tiered screening and selection of the title, abstract and full-text were performed. Studies of finite element analysis (FEA) were considered for inclusion that were written in English and revealed stress concentrations or strain at peri-implant bone level. There were included 20 FEA studies in total. Data were organized according to the following topics: bone layers, type of bone, osseointegration level, bone level, design of implant, diameter and length of implant, implant-abutment connection, type of supra-construction, loading axis, measurement units. The stress or strain at implant-bone contact was measured over all studies and numerical values estimated. Risks of overloading were accented as non-axial loading, misfits, cantilevers and the stability of peri-implant bone was related with the usage of platform switch connection of abutment. Peri-implant area could be affected by non-axial loading, cantilever prosthetic elements, crown/implant ratio, type of implant-abutment connection, misfits, properties of restoration materials and antagonistic tooth. The heterogeneity of finite element analysis studies limits systematization of data. Results of these studies are comparable with other findings of in vitro , in vivo , prospective and retrospective studies.

  12. Prosthetic Joint Infection

    PubMed Central

    Tande, Aaron J.

    2014-01-01

    SUMMARY Prosthetic joint infection (PJI) is a tremendous burden for individual patients as well as the global health care industry. While a small minority of joint arthroplasties will become infected, appropriate recognition and management are critical to preserve or restore adequate function and prevent excess morbidity. In this review, we describe the reported risk factors for and clinical manifestations of PJI. We discuss the pathogenesis of PJI and the numerous microorganisms that can cause this devastating infection. The recently proposed consensus definitions of PJI and approaches to accurate diagnosis are reviewed in detail. An overview of the treatment and prevention of this challenging condition is provided. PMID:24696437

  13. Prosthetic Leg Control in the Nullspace of Human Interaction.

    PubMed

    Gregg, Robert D; Martin, Anne E

    2016-07-01

    Recent work has extended the control method of virtual constraints, originally developed for autonomous walking robots, to powered prosthetic legs for lower-limb amputees. Virtual constraints define desired joint patterns as functions of a mechanical phasing variable, which are typically enforced by torque control laws that linearize the output dynamics associated with the virtual constraints. However, the output dynamics of a powered prosthetic leg generally depend on the human interaction forces, which must be measured and canceled by the feedback linearizing control law. This feedback requires expensive multi-axis load cells, and actively canceling the interaction forces may minimize the human's influence over the prosthesis. To address these limitations, this paper proposes a method for projecting virtual constraints into the nullspace of the human interaction terms in the output dynamics. The projected virtual constraints naturally render the output dynamics invariant with respect to the human interaction forces, which instead enter into the internal dynamics of the partially linearized prosthetic system. This method is illustrated with simulations of a transfemoral amputee model walking with a powered knee-ankle prosthesis that is controlled via virtual constraints with and without the proposed projection.

  14. Remote monitoring of lower-limb prosthetic socket fit using wireless technologies.

    PubMed

    Sahandi, R; Sewell, P; Noroozi, S; Hewitt, M

    2012-01-01

    Accurate fitting of a lower-limb prosthetic socket is the most important factor affecting amputee satisfaction and rehabilitation. The technology is now available to allow real-time monitoring of in-service pressure distribution of prosthetic limbs. This paper proposes a remote interfacial pressure monitoring system necessary for the assessment of fit. The suitability of a wireless ZigBee network due to its relevant technical specification is investigated. The system enables remote monitoring of a prosthetic socket and its fit under different operating conditions thereby improving design, efficiency and effectiveness. The data can be used by prosthetists and may also be recorded for future training or for patient progress monitoring. This can minimize the number of iterations by getting it right first time, thereby minimizing the number of replacement prostheses. Copyright © 2012 Informa UK, Ltd.

  15. Incidence of Prosthetic Complications associated with Implant-borne Prosthesis in a Sleep Disorder Center.

    PubMed

    Suneel, Venkatesh B; Kotian, Santhosh; Jujare, Ravikanth H; Shetty, Adarsh K; Nidhi, Sneh; Grover, Shehkar

    2017-09-01

    Obstructive sleep apnea (OSA) is one of the common prevalent conditions present worldwide. The process of abnormal habits related to clenching and grinding of teeth is referred to as bruxism and is characterized under the heading of parafunctional activity of the masticatory system. Osseointegrated dental implants represent advancements in the field of odontology. Despite its high success rate, failure and complications are often associated with dental implant treatment due to a number of factors. Hence, we aimed for the present study to assess the incidence of prosthetic complications in patients rehabilitated with implant-borne prosthesis in a sleep disorder unit. The present study included the assessment of all the patients who underwent prosthetic rehabilitation by dental implants. An experienced registered prosthodontist was given duty for examination of all the cases from the record file data. Prosthetic complications in the patients were identified using photographs, radiographs, and all other relevant data of the patients obtained from the record files. All types of complications and other factors were recorded separately and analyzed. While correlating the prosthetic complications in OSA patients grouped based on number of dental implants, nonsignificant results were obtained. Significant correlation was observed while comparing the prosthetic complications divided based on type of prosthesis. Fracture of the porcelain was observed in four and eight cases respectively, of screwed and cemented dental implant cases. Some amount of significant correlation existed between the incidences of prosthetic complications and OSA. Proper history of the patients undergoing dental implant procedures should be taken to avoid failure.

  16. Two-stage reimplantation for treating prosthetic shoulder infections.

    PubMed

    Sabesan, Vani J; Ho, Jason C; Kovacevic, David; Iannotti, Joseph P

    2011-09-01

    Two-stage reimplantation for prosthetic joint infection reportedly has the lowest risk for recurrent infection. Most studies to date have evaluated revision surgery for infection using an anatomic prosthetic. As compared with anatomic prostheses, reverse total shoulder arthroplasty is reported to have a higher rate of infection. We determined reinfection rates, functional improvement, types and rates of complications, and influence of rotator cuff tissue on function for two-stage reimplantation for prosthetic joint infection treated with reverse shoulder arthroplasty. We retrospectively reviewed 27 patients treated with a two-stage reimplantation for prosthetic shoulder infection using a uniform protocol for management of infection; of these, 17 had reverse shoulder arthroplasty at second-stage surgery. Types of organisms cultured, recurrence rates, complications, function, and radiographic followup were reviewed for all patients. One of the 17 patients had recurrence of infection. The mean (± SD) Penn shoulder scores for patients treated with reverse shoulder arthroplasty improved from 24.9 ± 22.3 to 66.4 ± 20.8. The average motion at last followup was 123° ± 33° of forward flexion and 26° ± 8° of external rotation in patients treated with a reverse shoulder arthroplasty. The major complication rate was 35% in reverse shoulder arthroplasty, with five dislocations and one reinfection. There was no difference in final Penn score between patients with and without external rotation weakness. Shoulder function and pain improved in patients treated with a second-stage reimplantation of a reverse prosthesis and the reinfection rate was low. Level IV, case series. See Guidelines for Authors for a complete description of levels of evidence.

  17. 21 CFR 895.101 - Prosthetic hair fibers.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Prosthetic hair fibers. 895.101 Section 895.101 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES BANNED DEVICES Listing of Banned Devices § 895.101 Prosthetic hair fibers. Prosthetic hair fibers are devices intended for implantation...

  18. Clinical characteristics, microbiology, and outcomes of prosthetic joint infection in Taiwan.

    PubMed

    Tsai, Jen-Chih; Sheng, Wang-Huei; Lo, Wan-Yu; Jiang, Ching-Chuan; Chang, Shan-Chwen

    2015-04-01

    Prosthetic joint infection (PJI) after total knee or hip replacement is a devastating complication associated with substantial morbidity and economic cost. The incidence of prosthetic joint infection is increasing as the use of mechanical joint replacement increases. The treatment approach to prosthetic joint infection is based on different clinical situations such as a patient's comorbidities, epidemic microbiology data, and surgical procedures. The aim of our study was to understand clinical characteristics of prosthetic joint infection, the microbiology of the prosthetic joint infection, and the outcomes of different treatment strategies during 2006-2011. We retrospectively collected cases of prosthetic joint infection in the National Taiwan University Hospital between January 1, 2006 and December 31, 2011. The patients' characteristics, microbiology, outcomes, and factors associated with treatment success were recorded. One hundred and forty-four patients were identified as having PJI. Of these, 92 patients were entered into per-protocol analysis. Staphylococcus aureus was the most common causative organism (29.9%), followed by coagulase-negative Staphylococci (16.7%), and Enterococci (9.7%). The overall treatment success rate was 50%. Patients who received a two-stage revision had a better outcome, compared to patients who underwent other types of surgeries (70% vs. 32.7%, respectively; p < 0.001). In multivariate analysis, the two-stage revision was significantly associated with treatment success (odds ratio = 3.923, 95% confidence interval = 1.53-10.04). Our study demonstrates that Staphylococcus aureus was the most common causative organisms in PJI. Performing two-stage revisions was significantly associated with a better outcome. Copyright © 2013. Published by Elsevier B.V.

  19. Reduced prosthetic stiffness lowers the metabolic cost of running for athletes with bilateral transtibial amputations.

    PubMed

    Beck, Owen N; Taboga, Paolo; Grabowski, Alena M

    2017-04-01

    Inspired by the springlike action of biological legs, running-specific prostheses are designed to enable athletes with lower-limb amputations to run. However, manufacturer's recommendations for prosthetic stiffness and height may not optimize running performance. Therefore, we investigated the effects of using different prosthetic configurations on the metabolic cost and biomechanics of running. Five athletes with bilateral transtibial amputations each performed 15 trials on a force-measuring treadmill at 2.5 or 3.0 m/s. Athletes ran using each of 3 different prosthetic models (Freedom Innovations Catapult FX6, Össur Flex-Run, and Ottobock 1E90 Sprinter) with 5 combinations of stiffness categories (manufacturer's recommended and ± 1) and heights (International Paralympic Committee's maximum competition height and ± 2 cm) while we measured metabolic rates and ground reaction forces. Overall, prosthetic stiffness [fixed effect (β) = 0.036; P = 0.008] but not height ( P ≥ 0.089) affected the net metabolic cost of transport; less stiff prostheses reduced metabolic cost. While controlling for prosthetic stiffness (in kilonewtons per meter), using the Flex-Run (β = -0.139; P = 0.044) and 1E90 Sprinter prostheses (β = -0.176; P = 0.009) reduced net metabolic costs by 4.3-4.9% compared with using the Catapult prostheses. The metabolic cost of running improved when athletes used prosthetic configurations that decreased peak horizontal braking ground reaction forces (β = 2.786; P = 0.001), stride frequencies (β = 0.911; P < 0.001), and leg stiffness values (β = 0.053; P = 0.009). Remarkably, athletes did not maintain overall leg stiffness across prosthetic stiffness conditions. Rather, the in-series prosthetic stiffness governed overall leg stiffness. The metabolic cost of running in athletes with bilateral transtibial amputations is influenced by prosthetic model and stiffness but not height. NEW & NOTEWORTHY We measured the

  20. Prosthetic Aortic Valves: Challenges and Solutions

    PubMed Central

    Musumeci, Lucia; Jacques, Nicolas; Hego, Alexandre; Nchimi, Alain; Lancellotti, Patrizio; Oury, Cécile

    2018-01-01

    Aortic Valve Disease (AVD) is the most common Valvular Heart Disease (VHD), affecting millions of people worldwide. Severe AVD is treated in most cases with prosthetic aortic valve replacement, which involves the substitution of the native aortic valve with a prosthetic one. In this review we will discuss the different types of prosthetic aortic valves available for implantation and the challenges faced by patients, medical doctors, researchers and manufacturers, as well as the approaches that are taken to overcome them. PMID:29868612

  1. Changes in ganglion cell physiology during retinal degeneration influence excitability by prosthetic electrodes

    NASA Astrophysics Data System (ADS)

    Cho, Alice; Ratliff, Charles; Sampath, Alapakkam; Weiland, James

    2016-04-01

    Objective. Here we investigate ganglion cell physiology in healthy and degenerating retina to test its influence on threshold to electrical stimulation. Approach. Age-related Macular Degeneration and Retinitis Pigmentosa cause blindness via outer retinal degeneration. Inner retinal pathways that transmit visual information to the central brain remain intact, so direct electrical stimulation from prosthetic devices offers the possibility for visual restoration. Since inner retinal physiology changes during degeneration, we characterize physiological properties and responses to electrical stimulation in retinal ganglion cells (RGCs) of both wild type mice and the rd10 mouse model of retinal degeneration. Main results. Our aggregate results support previous observations that elevated thresholds characterize diseased retinas. However, a physiology-driven classification scheme reveals distinct sub-populations of ganglion cells with thresholds either normal or strongly elevated compared to wild-type. When these populations are combined, only a weakly elevated threshold with large variance is observed. The cells with normal threshold are more depolarized at rest and exhibit periodic oscillations. Significance. During degeneration, physiological changes in RGCs affect the threshold stimulation currents required to evoke action potentials.

  2. Prosthetic Engineering

    MedlinePlus

    ... torque adapter in the pylons of transtibial amputees. Energy Storage & Release Many ambulatory lower limb amputees exhibit ... Future Directions Current Project Summaries Development of Controlled Energy Storage and Release Prosthetic Foot Development of Inverting- ...

  3. Risks and Challenges of Surgery for Aortic Prosthetic Valve Endocarditis.

    PubMed

    Grubitzsch, Herko; Tarar, Waharat; Claus, Benjamin; Gabbieri, Davide; Falk, Volkmar; Christ, Torsten

    2018-03-01

    Prosthetic valve endocarditis is the most severe form of infective endocarditis. This study assessed the risks and challenges of surgery for aortic prosthetic valve endocarditis. In total, 116 consecutive patients (98 males, age 65.2±12.7years), who underwent redo-surgery for active aortic prosthetic valve endocarditis between 2000 and 2014, were reviewed. Cox regression analysis was used to identify factors for aortic root destructions as well as for morbidity and mortality. Median follow-up was 3.8 years (0-13.9 years). Aortic root destructions (42 limited and 29 multiple lesions) were associated with early prosthetic valve endocarditis and delayed diagnosis (≥14 d), but not with mortality. There were 16 (13.8%) early (≤30 d) and 32 (27.6%) late (>30 days) deaths. Survival at 1, 5, and 10 years was 72±4.3%, 56±5.4%, and 46±6.4%, respectively. The cumulative incidence of death, reinfection, and reoperation was 19.0% at 30days and 36.2% at 1year. Delayed diagnosis, concomitant procedures, and EuroSCORE II >20% were predictors for early mortality and need for mechanical circulatory support, age >70years, and critical preoperative state were predictors for late mortality. In their absence, survival at 10 years was 70±8.4%. Reinfections and reoperations occurred more frequently if ≥1 risk factor for endocarditis and aortic root destructions were present. At 10 years, freedom from reinfection and reoperation was 89±4.2% and 91±4.0%. The risks of death, reinfection, and reoperation are significant within the first year after surgery for aortic prosthetic valve endocarditis. Early diagnosis and aortic root destructions are the most important challenges, but advanced age, critical preoperative state, and the need for mechanical circulatory support determine long-term survival. Copyright © 2017 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B

  4. Histopathological and Immunohistochemical Evaluation of Pannus Tissue in Patients with Prosthetic Valve Dysfunction.

    PubMed

    Karakoyun, Süleyman; Ozan Gürsoy, Mustafa; Yesin, Mahmut; Kalçık, Macit; Astarcıoğlu, Mehmet Ali; Gündüz, Sabahattin; Emrah Oğuz, Ali; Çoban Kökten, Şermin; Nimet Karadayı, Ayşe; Tuncer, Altuğ; Köksal, Cengiz; Gökdeniz, Tayyar; Özkan, Mehmet

    2016-01-01

    Prosthetic valve dysfunction due to pannus formation is a rare but serious complication. Currently, limited data are available concerning the pathogenesis and immunohistochemical properties of pannus. The study aim was to investigate the morphological, histopathological and immunohistochemical characteristics of pannus formation in patients with prosthetic valve dysfunction. A total of 35 patients (10 males, 25 females; mean age 44 ± 16 years) who had undergone re-do valve surgery due to prosthetic valve obstruction was enrolled in the study. Immunohistochemical studies were aimed at evaluating the expression of alphasmooth muscle actin (α-SMA) and desmin in myofibroblasts and smooth muscle cells; epithelial membrane antigen (EMA) in epithelial cells; and CD34, Factor VIII and vascular endothelial growth factor (VEGF) in endothelial cells. Matrix metalloproteinases (MMPs) -2 and -9, and transforming growth factor-beta (TGF-β) were used to demonstrate cytokine release from macrophages, leukocytes, fibroblasts and myofibroblasts. Pannus appeared as a tough and thick tissue hyperplasia which began from outside the suture ring in the periannular region and extended to the inflow and outflow surfaces of the prosthetic valves. Histopathological analysis showed the pannus tissue to consist of chronic inflammatory cells (lymphocytes, plasma cells, macrophages and foreign body giant cells), spindle cells such as myofibroblasts, capillary blood vessels and endothelial cells laying down the lumens. Calcification was present in the pannus tissue of 19 explanted prostheses. Immunohistochemical studies revealed positive α-SMA expression in all patients, whereas 60.5% of patients were positive for desmin, 50% for EMA, 42.1% for VEGF, 39.5% for TBF-β, 42.1% for MMP-2, 86.8% for CD34, and 97.4% for Factor VIII. MMP-9 was negative in all patients. Pannus tissue appears to be formed as the result of a neointimal response in periannular regions of prosthetic valves that consist

  5. Advances in upper extremity prosthetics.

    PubMed

    Zlotolow, Dan A; Kozin, Scott H

    2012-11-01

    Until recently, upper extremity prostheses had changed little since World War II. In 2006, the Defense Advanced Research Projects Agency responded to an increasing number of military amputees with the Revolutionizing Prosthetics program. The program has yielded several breakthroughs both in the engineering of new prosthetic arms and in the control of those arms. Direct brain-wave control of a limb with 22° of freedom may be within reach. In the meantime, advances such as individually powered digits have opened the door to multifunctional full and partial hand prostheses. Restoring sensation to the prosthetic limb remains a major challenge to full integration of the limb into a patient's self-image. Copyright © 2012 Elsevier Inc. All rights reserved.

  6. Circuit For Control Of Electromechanical Prosthetic Hand

    NASA Technical Reports Server (NTRS)

    Bozeman, Richard J., Jr.

    1995-01-01

    Proposed circuit for control of electromechanical prosthetic hand derives electrical control signals from shoulder movements. Updated, electronic version of prosthesis, that includes two hooklike fingers actuated via cables from shoulder harness. Circuit built around favored shoulder harness, provides more dexterous movement, without incurring complexity of computer-controlled "bionic" or hydraulically actuated devices. Additional harness and potentiometer connected to similar control circuit mounted on other shoulder. Used to control stepping motor rotating hand about prosthetic wrist to one of number of angles consistent with number of digital outputs. Finger-control signals developed by circuit connected to first shoulder harness transmitted to prosthetic hand via sliprings at prosthetic wrist joint.

  7. Redo surgery risk in patients with cardiac prosthetic valve dysfunction

    PubMed Central

    Maciejewski, Marek; Piestrzeniewicz, Katarzyna; Bielecka-Dąbrowa, Agata; Piechowiak, Monika; Jaszewski, Ryszard

    2011-01-01

    Introduction The aim of the study was to analyse the risk factors of early and late mortality in patients undergoing the first reoperation for prosthetic valve dysfunction. Material and methods A retrospective observational study was performed in 194 consecutive patients (M = 75, F = 119; mean age 53.2 ±11 years) with a mechanical prosthetic valve (n = 103 cases; 53%) or bioprosthesis (91; 47%). Univariate and multivariate Cox statistical analysis was performed to determine risk factors of early and late mortality. Results The overall early mortality was 18.6%: 31.4% in patients with symptoms of NYHA functional class III-IV and 3.4% in pts in NYHA class I-II. Multivariate analysis identified symptoms of NYHA class III-IV and endocarditis as independent predictors of early mortality. The overall late mortality (> 30 days) was 8.2% (0.62% year/patient). Multivariate analysis identified age at the time of reoperation as a strong independent predictor of late mortality. Conclusions Reoperation in patients with prosthetic valves, performed urgently, especially in patients with symptoms of NYHA class III-IV or in the case of endocarditis, bears a high mortality rate. Risk of planned reoperation, mostly in patients with symptoms of NYHA class I-II, does not differ from the risk of the first operation. PMID:22291767

  8. Major lower limb amputations in the Marshall Islands: incidence, prosthetic prescription, and prosthetic use after 6-18 months.

    PubMed

    Harding, Katherine

    2005-03-01

    The Republic of the Marshall Islands has been recognised anecdotally to have high rates of major lower limb amputations secondary to diabetes. During 2001, a prosthetics service was introduced as part of the rehabilitation service at Majuro Hospital. 1. To determine the incidence of major lower limb amputations over a one year period from 2002 to 2003. 2. To evaluate the proportion of patients suitable for prosthetic fitting. 3. Determine survival rates and usage of prostheses six to eighteen months after prosthetic fitting. Amputation rates were established through review of the surgical logs at the two hospitals in the Marshall Islands. Prosthetic fitting rates were determined using records from Majuro hospital rehabilitation service. Follow up interviews were conducted with fifteen surviving patients who received prostheses during the study period, to investigate prosthetic use. The incidence of major lower limb amputation was found to be 79.5 per 100,000 population, with all forty-five amputations being associated with diabetes. Just over a third of these patients were discharged from rehabilitation with a prosthesis. Fifteen of the patients were followed up post discharge. All of the thirteen with transtibial amputations were found to be using their prosthesis at least some of the day. The two patients with transfemoral amputations had ceased to walk with their prosthesis. This study identified a very high rate of lower limb amputation in the Marshall Islands by world standards. Prosthetic fitting rates and follow up results were comparable to those reported by others, and indicate that small, geographically isolated island nations such as the Marshall Islands are able to provide a successful prosthetics and rehabilitation service locally.

  9. The influence of standards and clinical guidelines on prosthetic and orthotic service quality: a scoping review.

    PubMed

    Sadeghi-Demneh, Ebrahim; Forghany, Saeed; Onmanee, Pornsuree; Trinler, Ursula; Dillon, Michael P; Baker, Richard

    2017-06-20

    Standards and guidelines are an integral part of prosthetic and orthotic service delivery in the developed world underpinned by an assumption that they lead to improved services. Implementing them has a cost, however, and that cost needs to be justified, particularly in resource-limited environments. This scoping review thus asks the question, "What is the evidence of the impact of standards and guidelines on service delivery outcomes in prosthetics and orthotics?" A structured search of three electronic databases (Medline, Scopus and Web of Science) followed by manual searching of title, abstract and full text, yielded 29 articles. Four categories of papers were identified: Descriptions and Commentaries (17 papers), Guideline Development (7), Guideline Testing (2) and Standards implementation (3). No articles were explicitly designed to assess the impact of standards and guidelines on service delivery outcomes in prosthetics and orthotics. Studies tended to be commentaries on or descriptions of guideline development, testing or implementation of standards. The literature is not sufficiently well developed to warrant the cost and effort of a systematic review. Future primary research should seek to demonstrate whether and how guidelines and standards improve the outcomes for people that require prostheses, orthoses and other assistive devices. Implications for Rehabilitation International Standards and Clinical Guidelines are now an integral part of clinical service provision in prosthetics and orthotics in the developed world. Complying with standards and guidelines has a cost and, particularly in resource-limited environments, it should be possible to justify this in terms of the resulting benefits. This scoping review concludes that there have been no previous studies designed to directly quantify the effects of implementing standards and guidelines on service delivery.

  10. Concerns of anophthalmic patients-a comparison between cryolite glass and polymethyl methacrylate prosthetic eye wearers.

    PubMed

    Rokohl, Alexander C; Koch, Konrad R; Adler, Werner; Trester, Marc; Trester, Wolfgang; Pine, Nicola S; Pine, Keith R; Heindl, Ludwig M

    2018-06-01

    To compare the concerns of experienced cryolite glass and (poly)methyl methacrylate (PMMA) prosthetic eye wearers. One hundred six experienced cryolite glass and 63 experienced PMMA prosthetic eye wearers completed an anonymous questionnaire regarding general and specific prosthetic eye concerns at least 2 years after natural eye loss. From these independent anophthalmic populations, we identified 34 case-control pairs matched for the known influencing demographic variables of gender, occupation, age, and time since natural eye loss. The levels of concern were significantly lower in the cryolite glass group than those in the PMMA group for the following: loss of balance (p < 0.001), phantom sight vision (p < 0.001), pain (p < 0.001), receiving good advice (p = 0.001), fullness of orbit (p = 0.001), size (p = 0.007), direction of gaze relative to the healthy fellow eye (p = 0.005), eye lid contour (p = 0.037), comfort of the prosthetic eye (p < 0.001), colour relative to the healthy fellow eye (p < 0.001), and retention of the prosthetic eye (p < 0.001). Concerns about watering, crusting, discharge, visual perception, appearance, movement of the prosthetic eye, and health of the remaining eye were not significantly different between both groups. The results of this study showed that many general and specific levels of concern were significantly lower for cryolite glass prosthetic eye wearers than for PMMA prosthetic eye wearers. The question of why there are significant differences and to what extent the material of the prosthesis (cryolite glass or PMMA) has an impact on various concerns remains unanswered and should be addressed in a prospective comparative multicentre trial.

  11. Prevention of Infection in Orthopedic Prosthetic Surgery.

    PubMed

    Chirca, Ioana; Marculescu, Camelia

    2017-06-01

    Total joint arthroplasty is a generally safe orthopedic procedure; however, infection is a potentially devastating complication. Multiple risk factors have been identified for development of prosthetic joint infections. Identification of patients at risk and preoperative correction of known risk factors, such as smoking, diabetes mellitus, anemia, malnutrition, and decolonization of Staphylococcus carriers, represent well-established actions to decrease the infection risk. Careful operative technique, proper draping and skin preparation, and appropriate selection and dosing of antimicrobials for perioperative prophylaxis are also very important in prevention of infection. Published by Elsevier Inc.

  12. Anaerobic prosthetic joint infection.

    PubMed

    Shah, Neel B; Tande, Aaron J; Patel, Robin; Berbari, Elie F

    2015-12-01

    In an effort to improve mobility and alleviate pain from degenerative and connective tissue joint disease, an increasing number of individuals are undergoing prosthetic joint replacement in the United States. Joint replacement is a highly effective intervention, resulting in improved quality of life and increased independence [1]. By 2030, it is predicted that approximately 4 million total hip and knee arthroplasties will be performed yearly in the United States [2]. One of the major complications associated with this procedure is prosthetic joint infection (PJI), occurring at a rate of 1-2% [3-7]. In 2011, the Musculoskeletal Infectious Society created a unifying definition for prosthetic joint infection [8]. The following year, the Infectious Disease Society of America published practice guidelines that focused on the diagnosis and management of PJI. These guidelines focused on the management of commonly encountered organisms associated with PJI, including staphylococci, streptococci and select aerobic Gram-negative bacteria. However, with the exception of Propionibacterium acnes, management of other anaerobic organisms was not addressed in these guidelines [1]. Although making up approximately 3-6% of PJI [9,10], anaerobic microorganisms cause devastating complications, and similar to the more common organisms associated with PJI, these bacteria also result in significant morbidity, poor outcomes and increased health-care costs. Data on diagnosis and management of anaerobic PJI is mostly derived from case reports, along with a few cohort studies [3]. There is a paucity of published data outlining factors associated with risks, diagnosis and management of anaerobic PJI. We therefore reviewed available literature on anaerobic PJI by systematically searching the PubMed database, and collected data from secondary searches to determine information on pathogenesis, demographic data, clinical features, diagnosis and management. We focused our search on five commonly

  13. [Incidence of hip and knee prosthetic infections in a specialized center of Mexico City].

    PubMed

    Franco-Cendejas, Rafael; Contreras-Córdova, Erika Lizbeth; Mondragón-Eguiluz, Jaime Arturo; Vanegas-Rodríguez, Edgar Samuel; Ilizaliturri-Sánchez, Víctor Manuel; Galindo-Fraga, Arturo

    Hip and knee prosthetic replacements have proven to be the most appropriate treatment in the joints that do not benefit from medical or arthroscopic interventions; however, infections are the most feared complication. It is recommended that the incidence of infection should not exceed 2%. This was an observational, prospective, longitudinal and observational study conducted in patients fitted with a prosthetic joint from August 2011 to July 2012. Patients were followed up pre and post-surgery for one year to identify a prosthetic infection, diagnosed using international parameters. We calculated the incidence of prosthetic infection, as well as the incidence density. A total of 339 patients (179 hip and 160 knee) were included. Variations in the time of pre-operative antibiotics' administration were observed. Six prosthetic infections were identified with an incidence rate of 1.79/339 arthroplasties, 2.2/179 hip procedures, and 1.25/160 knee arthroplasties. An incidence density of 0.02/year for hip arthroplasties and 0.11/year for knee procedures was identified. There were 4 infections of hip and 2 of knee. Five infections were acute and one chronic. The isolated microorganisms were E. faecalis, S. epidermidis (2), S. mitis, S. aureus and P. stomatis. The incidence of prosthetic joint infection in the first year of follow-up at our centre is within the recommended parameters. Surgical techniques and organizational practices influence the results. Copyright © 2016 Academia Mexicana de Cirugía A.C. Publicado por Masson Doyma México S.A. All rights reserved.

  14. Design and clinical outcome of a novel 3D-printed prosthetic joint replacement for the human temporomandibular joint.

    PubMed

    Ackland, David; Robinson, Dale; Lee, Peter Vee Sin; Dimitroulis, George

    2018-05-11

    Stock prosthetic temporomandibular joint replacements come in limited sizes, and do not always encompass the joint anatomy that presents clinically. The aims of this study were twofold. Firstly, to design a personalized prosthetic total joint replacement for the treatment of a patient's end-stage temporomandibular joint osteoarthritis, to implant the prosthesis into the patient, and assess clinical outcome 12-months post-operatively; and secondly, to evaluate the influence of changes in prosthetic condyle geometry on implant load response during mastication. A 48-year-old female patient with Grade-5 osteoarthritis to the left temporomandibular joint was recruited, and a prosthesis developed to match the native temporomandibular joint anatomy. The prosthesis was 3D printed, sterilized and implanted into the patient, and pain and function measured 12-months post-operatively. The prosthesis load response during a chewing-bite and maximum-force bite was evaluated using a personalized multi-body musculoskeletal model. Simulations were performed after perturbing condyle thickness, neck length and head sphericity. Increases in prosthetic condyle neck length malaligned the mandible and perturbed temporomandibular joint force. Changes in condylar component thickness greatly influenced fixation screw stress response, while a more eccentric condylar head increased prosthetic joint-contact loading. Post-operatively, the prosthetic temporomandibular joint surgery reduced patient pain from 7/10 to 1/10 on a visual analog scale, and increased intercisal opening distance from 22 mm to 38 mm. This study demonstrates effectiveness of a personalized prosthesis that may ultimately be adapted to treat a wide-range of end-stage temporomandibular joint conditions, and highlights sensitivity of prosthesis load response to changes in condylar geometry. Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. Diagnostic performance of FDG PET or PET/CT in prosthetic infection after arthroplasty: a meta-analysis.

    PubMed

    Jin, H; Yuan, L; Li, C; Kan, Y; Hao, R; Yang, J

    2014-03-01

    The purpose of this study was to systematically review and perform a meta-analysis of published data regarding the diagnostic performance of positron emission tomography (PET) or PET/computed tomography (PET/CT) in prosthetic infection after arthroplasty. A comprehensive computer literature search of studies published through May 31, 2012 regarding PET or PET/CT in patients suspicious of prosthetic infection was performed in PubMed/MEDLINE, Embase and Scopus databases. Pooled sensitivity and specificity of PET or PET/CT in patients suspicious of prosthetic infection on a per prosthesis-based analysis were calculated. The area under the receiver-operating characteristic (ROC) curve was calculated to measure the accuracy of PET or PET/CT in patients with suspicious of prosthetic infection. Fourteen studies comprising 838 prosthesis with suspicious of prosthetic infection after arthroplasty were included in this meta-analysis. The pooled sensitivity of PET or PET/CT in detecting prosthetic infection was 86% (95% confidence interval [CI] 82-90%) on a per prosthesis-based analysis. The pooled specificity of PET or PET/CT in detecting prosthetic infection was 86% (95% CI 83-89%) on a per prosthesis-based analysis. The area under the ROC curve was 0.93 on a per prosthesis-based analysis. In patients suspicious of prosthetic infection, FDG PET or PET/CT demonstrated high sensitivity and specificity. FDG PET or PET/CT are accurate methods in this setting. Nevertheless, possible sources of false positive results and influcing factors should kept in mind.

  16. Toxicology of antimicrobial nanoparticles for prosthetic devices

    PubMed Central

    Nuñez-Anita, Rosa Elvira; Acosta-Torres, Laura Susana; Vilar-Pineda, Jorge; Martínez-Espinosa, Juan Carlos; de la Fuente-Hernández, Javier; Castaño, Víctor Manuel

    2014-01-01

    Advances in nanotechnology are producing an accelerated proliferation of new nanomaterial composites that are likely to become an important source of engineered health-related products. Nanoparticles with antifungal effects are of great interest in the formulation of microbicidal materials. Fungi are found as innocuous commensals and colonize various habitats in and on humans, especially the skin and mucosa. As growth on surfaces is a natural part of the Candida spp. lifestyle, one can expect that Candida organisms colonize prosthetic devices, such as dentures. Macromolecular systems, due to their properties, allow efficient use of these materials in various fields, including the creation of reinforced nanoparticle polymers with antimicrobial activity. This review briefly summarizes the results of studies conducted during the past decade and especially in the last few years focused on the toxicity of different antimicrobial polymers and factors influencing their activities, as well as the main applications of antimicrobial polymers in dentistry. The present study addresses aspects that are often overlooked in nanotoxicology studies, such as careful time-dependent characterization of agglomeration and ion release. PMID:25187703

  17. Review of Prosthetic Joint Infection from Listeria monocytogenes.

    PubMed

    Bader, Gilbert; Al-Tarawneh, Mohammed; Myers, James

    2016-12-01

    Prosthetic joint infection from Listeria monocytogenes is rare. We decided to shed light on this illness and review the reported cases to better understand its characteristics. We conducted a comprehensive review of the English literature using PubMed. We also included one case that we had managed. We found 25 cases of prosthetic joint infection from L. monocytogenes reported individually and a retrospective study of 43 cases of joint and bone listerial infection, including 34 with prosthetic joint infection, conducted in France. We have described their clinical and para-clinical features and tried to elaborate on the pathophysiology, treatment, and prevention. Prosthetic joint infection from L. monocytogenes is mainly late. Systemic inflammation may be absent. Although rare, it must be suspected in patients at high risk for both prosthetic joint and listerial infections. In addition, those patients must be instructed on appropriate preventive measures.

  18. Pannus-related prosthetic valve dysfunction. Case report

    PubMed Central

    MOLDOVAN, MARIA-SÎNZIANA; BEDELEANU, DANIELA; KOVACS, EMESE; CIUMĂRNEAN, LORENA; MOLNAR, ADRIAN

    2016-01-01

    Pannus-related prosthetic valve dysfunction, a complication of mechanical prosthetic valve replacement, is rare, with a slowly progressive evolution, but it can be acute, severe, requiring surgical reintervention. We present the case of a patient with a mechanical single disc aortic prosthesis, with moderate prosthesis-patient mismatch, minor pannus found on previous ultrasound examinations, who presented to our service with angina pain with a duration of 1 hour, subsequently interpreted as non-ST segment elevation myocardial infarction (NSTEMI) syndrome. Coronarography showed normal epicardial coronary arteries, an ample movement of the prosthetic disc, without evidence of coronary thromboembolism, and Gated Single-Photon Emission Computerized Tomography (SPECT) with Technetium (Tc)-99m detected no perfusion defects. Transthoracic echocardiography (TTE) evidenced a dysfunctional prosthesis due to a subvalvular mass; transesophageal echocardiography (TOE) showed the interference of this mass, with a pannus appearance, with the closure of the prosthetic disc. Under conditions of repeated angina episodes, under anticoagulant treatment, surgery was performed, with the intraoperative confirmation of pannus and its removal. Postoperative evolution was favorable. This case reflects the diagnostic and therapeutic management problems of pannus-related prosthetic valve dysfunction. PMID:27004041

  19. Pannus-related prosthetic valve dysfunction. Case report.

    PubMed

    Moldovan, Maria-Sînziana; Bedeleanu, Daniela; Kovacs, Emese; Ciumărnean, Lorena; Molnar, Adrian

    2016-01-01

    Pannus-related prosthetic valve dysfunction, a complication of mechanical prosthetic valve replacement, is rare, with a slowly progressive evolution, but it can be acute, severe, requiring surgical reintervention. We present the case of a patient with a mechanical single disc aortic prosthesis, with moderate prosthesis-patient mismatch, minor pannus found on previous ultrasound examinations, who presented to our service with angina pain with a duration of 1 hour, subsequently interpreted as non-ST segment elevation myocardial infarction (NSTEMI) syndrome. Coronarography showed normal epicardial coronary arteries, an ample movement of the prosthetic disc, without evidence of coronary thromboembolism, and Gated Single-Photon Emission Computerized Tomography (SPECT) with Technetium (Tc)-99m detected no perfusion defects. Transthoracic echocardiography (TTE) evidenced a dysfunctional prosthesis due to a subvalvular mass; transesophageal echocardiography (TOE) showed the interference of this mass, with a pannus appearance, with the closure of the prosthetic disc. Under conditions of repeated angina episodes, under anticoagulant treatment, surgery was performed, with the intraoperative confirmation of pannus and its removal. Postoperative evolution was favorable. This case reflects the diagnostic and therapeutic management problems of pannus-related prosthetic valve dysfunction.

  20. Intraoperative Considerations for Treatment/Prevention of Prosthetic Joint Infection.

    PubMed

    Suleiman, Linda I; Mesko, Daniel R; Nam, Denis

    2018-06-23

    Innovative measures have recently been proposed to prevent periprosthetic joint infection following total hip and knee arthroplasty. We sought to review these recent innovations to determine the reported reduction in periprosthetic joint infection. The most recent literature demonstrates promising results in regard to hydrofiber dressings as an independent risk factor for primary prosthetic joint infection reduction, which in turn is also linked with cost savings. As our understanding of safe yet effective concentrations of antiseptic solutions develops, dilute betadine in particular has demonstrated encouraging efficacy which warrants continued investigation through controlled trials. In summary, we found that the application of a hydrofiber dressing may prove beneficial in decreasing the risk of prosthetic joint infection following primary total hip and knee arthroplasty. The gold standard for an infection prevention protocol continues to be explored and optimized.

  1. Prosthetic valve endocarditis.

    PubMed Central

    Moore-Gillon, J; Eykyn, S J; Phillips, I

    1983-01-01

    During 1965 to 1982, 32 episodes of infective endocarditis on prosthetic valves in 30 patients were treated at this hospital. In early endocarditis (presenting within four months of operation) staphylococci were the organisms most commonly responsible. Early endocarditis appears to be declining in incidence and is largely preventable; sternal sepsis was the main predisposing factor, requiring urgent and effective treatment. Streptococci were the most common organisms in late onset disease, but as with natural valve endocarditis a wide range or organisms was responsible. All but one of the patients with early onset disease were treated conservatively, but mortality was high; prompt surgical replacement of infected prostheses is probably indicated in such patients. Medical management was effective in most patients with late onset disease, and for them early surgical intervention may not be justified. PMID:6412805

  2. Kinematics in the terminal swing phase of unilateral transfemoral amputees: microprocessor-controlled versus swing-phase control prosthetic knees.

    PubMed

    Mâaref, Khaled; Martinet, Noël; Grumillier, Constance; Ghannouchi, Slaheddine; André, Jean Marie; Paysant, Jean

    2010-06-01

    To analyze the spatiotemporal parameters in the terminal swing phase of the prosthetic limb in unilateral transfemoral amputees (TFAs) compared with a group of asymptomatic subjects, and to identify a latency period (LP) in the TFA between the full extension of the prosthetic knee and the initial ground contact of the ipsilateral foot. To study the correlation between the LP and the duration of the swing phase. To evaluate the influence of the type of knee, the time since amputation, and the amputation level on the latency period. Three-dimensional gait analysis with an optoelectronic device. Gait analysis laboratory of a re-education and functional rehabilitation service. TFA (n=29) and able-bodied (n=15) subjects. Not applicable. Spatiotemporal and kinematics gait parameters. The swing phase and the LP of the prosthetic limb, associated with a consequently longer single-limb stance phase in the intact limb, were significantly longer than those measured in the intact limbs of these subjects, as well as those measured on both lower limbs of the able-bodied subjects (P<.05). There is a positive correlation (P<.05; r(2)=.58 between the LP and the swing phase on the TFA's prosthetic side. The LP measured in the prosthetic limb of TFA with a swing-phase control prosthetic knee is significantly greater than in those using the microprocessor-controlled prosthetic knee (P<.05). Of negligible duration in able-bodied subjects and in the intact limb of TFA, the LP is significantly greater in the prosthetic limb. It can explain the lengthened swing phase on the prosthetic side of those subjects. The use of a microprocessor-controlled prosthetic knee allows the LP to be reduced. This LP appears to be necessary to insure the stability of the prosthetic knee. We suggest calling this time "confidence time." Copyright 2010 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  3. Management of Prosthetic Joint Infection.

    PubMed

    Tande, Aaron J; Gomez-Urena, Eric O; Berbari, Elie F; Osmon, Douglas R

    2017-06-01

    Although uncommon, prosthetic joint infection is a devastating complication. This challenging condition requires a coordinated management approach to achieve good patient outcomes. This review details the general principles to consider when managing patients with prosthetic joint infection. The different medical/surgical treatment strategies and how to appropriately select a strategy are discussed. The data to support each strategy are presented, along with discussion of antimicrobial strategies in specific situations. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. An extremely lightweight fingernail worn prosthetic interface device

    NASA Astrophysics Data System (ADS)

    Yetkin, Oguz; Ahluwalia, Simranjit; Silva, Dinithi; Kasi-Okonye, Isioma; Volker, Rachael; Baptist, Joshua R.; Popa, Dan O.

    2016-05-01

    Upper limb prosthetics are currently operated using several electromyography sensors mounted on an amputee's residual limb. In order for any prosthetic driving interface to be widely adopted, it needs to be responsive, lightweight, and out of the way when not being used. In this paper we discuss the possibility of replacing such electrodes with fingernail optical sensor systems mounted on the sound limb. We present a prototype device that can detect pinch gestures and communicate with the prosthetic system. The device detects the relative position of fingers to each other by measuring light transmitted via tissue. Applications are not limited to prosthetic control, but can be extended to other human-machine interfaces.

  5. Overview: Mechanism and Control of a Prosthetic Arm.

    PubMed

    Kulkarni, Tushar; Uddanwadiker, Rashmi

    2015-09-01

    Continuous growth in industrialization and lack of awareness in safety parameters the cases of amputations are growing. The search of safer, simpler and automated prosthetic arms for managing upper limbs is expected. Continuous efforts have been made to design and develop prosthetic arms ranging from simple harness actuated to automated mechanisms with various control options. However due the cost constraints, the automated prosthetic arms are still out of the reach of needy people. Recent data have shown that there is a wide scope to develop a low cost and light weight upper limb prosthesis. This review summarizes the various designs methodologies, mechanisms and control system developed by the researchers and the advances therein. Educating the patient to develop acceptability to prosthesis and using the same for the most basic desired functions of human hand, post amputation care and to improve patient's independent life is equally important. In conclusion it can be interpreted that there is a wide scope in design in an adaptive mechanism for opening and closing of the fingers using other methods of path and position synthesis. Simple mechanisms and less parts may optimize the cost factor. Reduction in the weight of the prosthesis may be achieved using polymers used for engineering applications. Control system will remain never ending challenge for the researchers, but it is essential to maintain the simplicity from the patients perspective.

  6. Smartphones as image processing systems for prosthetic vision.

    PubMed

    Zapf, Marc P; Matteucci, Paul B; Lovell, Nigel H; Suaning, Gregg J

    2013-01-01

    The feasibility of implants for prosthetic vision has been demonstrated by research and commercial organizations. In most devices, an essential forerunner to the internal stimulation circuit is an external electronics solution for capturing, processing and relaying image information as well as extracting useful features from the scene surrounding the patient. The capabilities and multitude of image processing algorithms that can be performed by the device in real-time plays a major part in the final quality of the prosthetic vision. It is therefore optimal to use powerful hardware yet to avoid bulky, straining solutions. Recent publications have reported of portable single-board computers fast enough for computationally intensive image processing. Following the rapid evolution of commercial, ultra-portable ARM (Advanced RISC machine) mobile devices, the authors investigated the feasibility of modern smartphones running complex face detection as external processing devices for vision implants. The role of dedicated graphics processors in speeding up computation was evaluated while performing a demanding noise reduction algorithm (image denoising). The time required for face detection was found to decrease by 95% from 2.5 year old to recent devices. In denoising, graphics acceleration played a major role, speeding up denoising by a factor of 18. These results demonstrate that the technology has matured sufficiently to be considered as a valid external electronics platform for visual prosthetic research.

  7. Amputation and Prosthetics

    MedlinePlus

    ... Extremity Prosthetics Find a hand surgeon near you. Videos Figures Figure 1: Thumb Prosthesis - not attached Figure ... or "in." Also, avoid using media types like "video," "article," and "picture." Tip 4: Your results can ...

  8. Fatigue testing of energy storing prosthetic feet.

    PubMed

    Toh, S L; Goh, J C; Tan, P H; Tay, T E

    1993-12-01

    This paper describes a simple approach to the fatigue testing of prosthetic feet. A fatigue testing machine for prosthetic feet was designed as part of the programme to develop an energy storing prosthetic foot (ESPF). The fatigue tester does not simulate the loading pattern on the foot during normal walking. However, cyclic vertical loads are applied to the heel and forefoot during heel-strike and toe-off respectively, for 500,000 cycles. The maximum load applied was chosen to be 1.5 times that applied by the bodyweight of the amputee and the test frequency was chosen to be 2 Hz to shorten the test duration. Four prosthetic feet were tested: two Lambda feet (a newly developed ESPF), a Kingsley SACH foot and a Proteor SACH foot. It was found that the Lambda feet have very good fatigue properties. The Kingsley SACH foot performed better than the Proteor model, with no signs of wear at the heel. The results obtained using the simple approach was found to be comparable to the results from more complex fatigue machines which simulate the load pattern during normal walking. This suggests that simple load simulating machines, which are less costly and require less maintenance, are useful substitutes in studying the fatigue properties of prosthetic feet.

  9. Graft-Sparing Strategy for Thoracic Prosthetic Graft Infection.

    PubMed

    Uchino, Gaku; Yoshida, Takeshi; Kakii, Bunpachi; Furui, Masato

    2018-04-01

     Thoracic prosthetic graft infection is a rare but serious complication with no standard management. We reported our surgical experience on graft-sparing strategy for thoracic prosthetic graft infection.  This study included patients who underwent graft-sparing surgery for thoracic prosthetic graft infection at Matsubara Tokushukai Hospital in Japan from January 2000 to October 2017.  There were 17 patients included in the analyses, with a mean age at surgery of 71.0 ± 10.5 years; 11 were men. In-hospital mortality was observed in five patients (29.4%).  Graft-sparing surgery for thoracic prosthetic graft infection is an alternative option particularly for early graft infection after hemiarch replacement. Georg Thieme Verlag KG Stuttgart · New York.

  10. 100 top-cited scientific papers in limb prosthetics.

    PubMed

    Eshraghi, Arezoo; Osman, Noor Azuan Abu; Gholizadeh, Hossein; Ali, Sadeeq; Shadgan, Babak

    2013-11-17

    Research has tremendously contributed to the developments in both practical and fundamental aspects of limb prosthetics. These advancements are reflected in scientific articles, particularly in the most cited papers. This article aimed to identify the 100 top-cited articles in the field of limb prosthetics and to investigate their main characteristics. Articles related to the field of limb prosthetics and published in the Web of Knowledge database of the Institute for Scientific Information (ISI) from the period of 1980 to 2012. The 100 most cited articles in limb prosthetics were selected based on the citation index report. All types of articles except for proceedings and letters were included in the study. The study design and level of evidence were determined using Sackett's initial rules of evidence. The level of evidence was categorized either as a systematic review or meta-analysis, randomized controlled trial, cohort study, case-control study, case series, expert opinion, or design and development. The top cited articles in prosthetics were published from 1980 to 2012 with a citation range of 11 to 90 times since publication. The mean citation rate was 24.43 (SD 16.7) times. Eighty-four percent of the articles were original publications and were most commonly prospective (76%) and case series studies (67%) that used human subjects (96%) providing level 4 evidence. Among the various fields, rehabilitation (47%), orthopedics (29%), and sport sciences (28%) were the most common fields of study. The study established that studies conducted in North America and were written in English had the highest citations. Top cited articles primarily dealt with lower limb prosthetics, specifically, on transtibial and transradial prosthetic limbs. Majority of the articles were experimental studies.

  11. Pre-Prosthetic surgical alterations in maxillectomy to enhance the prosthetic prognoses as part of rehabilitation of oral cancer patient

    PubMed Central

    El Fattah, Hisham; Zaghloul, Ashraf; Escuin, Tomas

    2012-01-01

    Objectives: After maxillectomy, prosthetic restoration of the resulting defect is an essential step because it signals the beginning of patient’s rehabilitation. The obturator used to restore the defect should be comfortable, restore adequate speech, deglutition, mastication, and be cosmetically acceptable, success will depend on the size and location of the defect and the quantity and integrity of the remaining structures, in addition to pre-prosthetic surgical preparation of defect site. Preoperative cooperation between the oncologist surgeon and the maxillofacial surgeon may allow obturation of a resultant defect by preservation of the premaxilla or the tuberosity on the defect side and maintaining the alveolar bone or teeth adjacent to the defect. This study evaluates the importance of pre-prosthetic surgical alterations at the time maxillectomy on the enhancement of the prosthetic prognoses as part of the rehabilitation of oral cancer patient. Study Design: The study was carried out between 2003- 2008, on 66 cancer patients(41 male-25 female) age ranged from 33 to 72 years, at National Cancer Institute, Cairo University, whom underwent maxillectomy surgery to remove malignant tumor as a part of cancer treatment. Patients were divided in two groups. Group A: Resection of maxilla followed by preprosthetic surgical preparation. Twenty-four cancer patients (13 male – 11 female). Group B: Resection of maxilla without any preprosthetic surgical preparation. Forty-two cancer patients (28 male-14 female). Results: Outcome variables measured included facial contour and aesthetic results, speech understandability, ability to eat solid foods, oronasal separation, socializing outside the home, and return-to-work status. Flap success and donor site morbidity were also studied. Conclusions: To improve the prosthetic restoration of maxillary defect resulting maxillary resection as part treatment of maxillofacial tumor depends on the close cooperation between

  12. Control method for prosthetic devices

    NASA Technical Reports Server (NTRS)

    Bozeman, Richard J., Jr. (Inventor)

    1995-01-01

    A control system and method for prosthetic devices is provided. The control system comprises a transducer for receiving movement from a body part for generating a sensing signal associated with that movement. The sensing signal is processed by a linearizer for linearizing the sensing signal to be a linear function of the magnitude of the distance moved by the body part. The linearized sensing signal is normalized to be a function of the entire range of body part movement from the no-shrug position of the moveable body part. The normalized signal is divided into a plurality of discrete command signals. The discrete command signals are used by typical converter devices which are in operational association with the prosthetic device. The converter device uses the discrete command signals for driving the moveable portions of the prosthetic device and its sub-prosthesis. The method for controlling a prosthetic device associated with the present invention comprises the steps of receiving the movement from the body part, generating a sensing signal in association with the movement of the body part, linearizing the sensing signal to be a linear function of the magnitude of the distance moved by the body part, normalizing the linear signal to be a function of the entire range of the body part movement, dividing the normalized signal into a plurality of discrete command signals, and implementing the plurality of discrete command signals for driving the respective moveable prosthesis device and its sub-prosthesis.

  13. How do prosthetic stiffness, height and running speed affect the biomechanics of athletes with bilateral transtibial amputations?

    PubMed Central

    Taboga, Paolo; Grabowski, Alena M.

    2017-01-01

    Limited available information describes how running-specific prostheses and running speed affect the biomechanics of athletes with bilateral transtibial amputations. Accordingly, we quantified the effects of prosthetic stiffness, height and speed on the biomechanics of five athletes with bilateral transtibial amputations during treadmill running. Each athlete performed a set of running trials with 15 different prosthetic model, stiffness and height combinations. Each set of trials began with the athlete running on a force-measuring treadmill at 3 m s−1, subsequent trials incremented by 1 m s−1 until they achieved their fastest attainable speed. We collected ground reaction forces (GRFs) during each trial. Prosthetic stiffness, height and running speed each affected biomechanics. Specifically, with stiffer prostheses, athletes exhibited greater peak and stance average vertical GRFs (β = 0.03; p < 0.001), increased overall leg stiffness (β = 0.21; p < 0.001), decreased ground contact time (β = −0.07; p < 0.001) and increased step frequency (β = 0.042; p < 0.001). Prosthetic height inversely associated with step frequency (β = −0.021; p < 0.001). Running speed inversely associated with leg stiffness (β = −0.58; p < 0.001). Moreover, at faster running speeds, the effect of prosthetic stiffness and height on biomechanics was mitigated and unchanged, respectively. Thus, prosthetic stiffness, but not height, likely influences distance running performance more than sprinting performance for athletes with bilateral transtibial amputations. PMID:28659414

  14. How do prosthetic stiffness, height and running speed affect the biomechanics of athletes with bilateral transtibial amputations?

    PubMed

    Beck, Owen N; Taboga, Paolo; Grabowski, Alena M

    2017-06-01

    Limited available information describes how running-specific prostheses and running speed affect the biomechanics of athletes with bilateral transtibial amputations. Accordingly, we quantified the effects of prosthetic stiffness, height and speed on the biomechanics of five athletes with bilateral transtibial amputations during treadmill running. Each athlete performed a set of running trials with 15 different prosthetic model, stiffness and height combinations. Each set of trials began with the athlete running on a force-measuring treadmill at 3 m s -1 , subsequent trials incremented by 1 m s -1 until they achieved their fastest attainable speed. We collected ground reaction forces (GRFs) during each trial. Prosthetic stiffness, height and running speed each affected biomechanics. Specifically, with stiffer prostheses, athletes exhibited greater peak and stance average vertical GRFs ( β = 0.03; p < 0.001), increased overall leg stiffness ( β = 0.21; p < 0.001), decreased ground contact time ( β = -0.07; p < 0.001) and increased step frequency ( β = 0.042; p < 0.001). Prosthetic height inversely associated with step frequency ( β = -0.021; p < 0.001). Running speed inversely associated with leg stiffness ( β = -0.58; p < 0.001). Moreover, at faster running speeds, the effect of prosthetic stiffness and height on biomechanics was mitigated and unchanged, respectively. Thus, prosthetic stiffness, but not height, likely influences distance running performance more than sprinting performance for athletes with bilateral transtibial amputations. © 2017 The Author(s).

  15. Dental prosthetic status and prosthetic needs of institutionalised elderly population in oldage homes of jabalpur city, madhya pradesh, India.

    PubMed

    Deogade, Suryakant C; Vinay, S; Naidu, Sonal

    2013-12-01

    Oral disorders are cumulative throughout life and hence unfavourable outcomes are likely to be greatest among the elderly. A descriptive cross-sectional study was conducted among institutionalized geriatric population in old-age homes of Jabalpur city, Madhya Pradesh, to assess their prosthetic status and prosthetic needs. A cross-sectional survey was conducted in all the four old-age homes of Jabalpur city, Madhya Pradesh state, India. All residents aged 60 years and above formed the study population. The recording of prosthetic status and prosthetic needs was carried out according to the World Health Organisation (WHO) Oral Health Assessment Form (1997). A total of 224 individuals were included in the study of which 123 were females and 101 were males. Seventy five percent of the females and 55 % of the males had no prostheses in their upper arch and 61 % of the females and 76 % of the males had no prostheses in their lower arch. More number of males presented with 'Bridges' in their upper arch when compared to females (P value = 0.006). Highest prosthetic need in males was multi-unit prosthesis (42 % in upper arch and 41 % in lower arch) whereas, females' required full prosthesis (39 % in both the upper arch and lower arches). Ageing presents some formidable challenges, particularly with the institutionalised. This study clearly demonstrates a high insufficiency of prosthetic care among the institutionalized elderly population. Any preparation towards the provision of oral health care should not be limited to treatment alone but, more importantly focus on empowering this elderly community with information and education programmes.

  16. Marker-based method to measure movement between the residual limb and a transtibial prosthetic socket.

    PubMed

    Childers, Walter Lee; Siebert, Steven

    2016-12-01

    Limb movement between the residuum and socket continues to be an underlying factor in limb health, prosthetic comfort, and gait performance yet techniques to measure this have been underdeveloped. Develop a method to measure motion between the residual limb and a transtibial prosthetic socket. Single subject, repeated measures with mathematical modeling. The gait of a participant with transtibial amputation was recorded using a motion capture system using a marker set that included arrays on the anterior distal tibia and the lateral epicondyle of the femur. The proximal or distal translation, anterior or posterior translation, and angular movements were quantified. A random Monte Carlo simulation based on the precision of the motion capture system and a model of the bone moving under the skin explored the technique's accuracy. Residual limb tissue stiffness was modeled as a linear spring based on data from Papaioannou et al. Residuum movement relative to the socket went through ~30 mm, 18 mm, and 15° range of motion. Root mean squared errors were 5.47 mm, 1.86 mm, and 0.75° when considering the modeled bone-skin movement in the proximal or distal, anterior or posterior, and angular directions, respectively. The measured movement was greater than the root mean squared error, indicating that this method can measure motion between the residuum and socket. The ability to quantify movement between the residual limb and the prosthetic socket will improve prosthetic treatment through the evaluation of different prosthetic suspensions, socket designs, and motor control of the prosthetic interface. © The International Society for Prosthetics and Orthotics 2015.

  17. Cobotic architecture for prosthetics.

    PubMed

    Faulring, Eeic L; Colgate, J Edward; Peshkin, Michael A

    2006-01-01

    We envision cobotic infinitely-variable transmissions (IVTs) as an enabling technology for haptics and prosthetics that will allow for increases in the dynamic range of these devices while simultaneously permitting reductions in actuator size and power requirements. Use of cobotic IVTs eliminates the need to make compromises on output flow and effort, which are inherent to choosing a fixed transmission ratio drivetrain. The result is a mechanism with enhanced dynamic range that extends continuously from a completely clutched state to a highly backdrivable state. This high dynamic range allows cobotic devices to control impedance with a high level of fidelity. In this paper, we discuss these and other motivations for using parallel cobotic transmission architecture in prosthetic devices.

  18. Systematic variation of prosthetic foot spring affects center-of-mass mechanics and metabolic cost during walking.

    PubMed

    Zelik, Karl E; Collins, Steven H; Adamczyk, Peter G; Segal, Ava D; Klute, Glenn K; Morgenroth, David C; Hahn, Michael E; Orendurff, Michael S; Czerniecki, Joseph M; Kuo, Arthur D

    2011-08-01

    Lower-limb amputees expend more energy to walk than non-amputees and have an elevated risk of secondary disabilities. Insufficient push-off by the prosthetic foot may be a contributing factor. We aimed to systematically study the effect of prosthetic foot mechanics on gait, to gain insight into fundamental prosthetic design principles. We varied a single parameter in isolation, the energy-storing spring in a prototype prosthetic foot, the controlled energy storage and return (CESR) foot, and observed the effect on gait. Subjects walked on the CESR foot with three different springs. We performed parallel studies on amputees and on non-amputees wearing prosthetic simulators. In both groups, spring characteristics similarly affected ankle and body center-of-mass (COM) mechanics and metabolic cost. Softer springs led to greater energy storage, energy return, and prosthetic limb COM push-off work. But metabolic energy expenditure was lowest with a spring of intermediate stiffness, suggesting biomechanical disadvantages to the softest spring despite its greater push-off. Disadvantages of the softest spring may include excessive heel displacements and COM collision losses. We also observed some differences in joint kinetics between amputees and non-amputees walking on the prototype foot. During prosthetic push-off, amputees exhibited reduced energy transfer from the prosthesis to the COM along with increased hip work, perhaps due to greater energy dissipation at the knee. Nevertheless, the results indicate that spring compliance can contribute to push-off, but with biomechanical trade-offs that limit the degree to which greater push-off might improve walking economy. © 2011 IEEE

  19. Systematic variation of prosthetic foot spring affects center-of-mass mechanics and metabolic cost during walking

    PubMed Central

    Zelik, Karl E.; Collins, Steven H.; Adamczyk, Peter G.; Segal, Ava D.; Klute, Glenn K.; Morgenroth, David C.; Hahn, Michael E.; Orendurff, Michael S.; Czerniecki, Joseph M.; Kuo, Arthur D.

    2014-01-01

    Lower-limb amputees expend more energy to walk than non-amputees and have an elevated risk of secondary disabilities. Insufficient push-off by the prosthetic foot may be a contributing factor. We aimed to systematically study the effect of prosthetic foot mechanics on gait, to gain insight into fundamental prosthetic design principles. We varied a single parameter in isolation, the energy-storing spring in a prototype prosthetic foot, the Controlled Energy Storage and Return (CESR) foot, and observed the effect on gait. Subjects walked on the CESR foot with three different springs. We performed parallel studies on amputees and on non-amputees wearing prosthetic simulators. In both groups, spring characteristics similarly affected ankle and body center-of-mass (COM) mechanics and metabolic cost. Softer springs led to greater energy storage, energy return and prosthetic limb COM push-off work. But metabolic energy expenditure was lowest with a spring of intermediate stiffness, suggesting biomechanical disadvantages to the softest spring despite its greater push-off. Disadvantages of the softest spring may include excessive heel displacements and COM collision losses. We also observed some differences in joint kinetics between amputees and non-amputees walking on the prototype foot. During prosthetic push-off, amputees exhibited reduced energy transfer from the prosthesis to the COM along with increased hip work, perhaps due to greater energy dissipation at the knee. Nevertheless, the results indicate that spring compliance can contribute to push-off, but with biomechanical trade-offs that limit the degree to which greater push-off might improve walking economy. PMID:21708509

  20. Innovations in prosthetic interfaces for the upper extremity.

    PubMed

    Kung, Theodore A; Bueno, Reuben A; Alkhalefah, Ghadah K; Langhals, Nicholas B; Urbanchek, Melanie G; Cederna, Paul S

    2013-12-01

    Advancements in modern robotic technology have led to the development of highly sophisticated upper extremity prosthetic limbs. High-fidelity volitional control of these devices is dependent on the critical interface between the patient and the mechanical prosthesis. Recent innovations in prosthetic interfaces have focused on several control strategies. Targeted muscle reinnervation is currently the most immediately applicable prosthetic control strategy and is particularly indicated in proximal upper extremity amputations. Investigation into various brain interfaces has allowed acquisition of neuroelectric signals directly or indirectly from the central nervous system for prosthetic control. Peripheral nerve interfaces permit signal transduction from both motor and sensory nerves with a higher degree of selectivity. This article reviews the current developments in each of these interface systems and discusses the potential of these approaches to facilitate motor control and sensory feedback in upper extremity neuroprosthetic devices.

  1. The role of vision processing in prosthetic vision.

    PubMed

    Barnes, Nick; He, Xuming; McCarthy, Chris; Horne, Lachlan; Kim, Junae; Scott, Adele; Lieby, Paulette

    2012-01-01

    Prosthetic vision provides vision which is reduced in resolution and dynamic range compared to normal human vision. This comes about both due to residual damage to the visual system from the condition that caused vision loss, and due to limitations of current technology. However, even with limitations, prosthetic vision may still be able to support functional performance which is sufficient for tasks which are key to restoring independent living and quality of life. Here vision processing can play a key role, ensuring that information which is critical to the performance of key tasks is available within the capability of the available prosthetic vision. In this paper, we frame vision processing for prosthetic vision, highlight some key areas which present problems in terms of quality of life, and present examples where vision processing can help achieve better outcomes.

  2. [Factors influencing activity of oral anticoagulants. Interactions with drugs and food].

    PubMed

    Sawicka-Powierza, Jolanta; Rogowska-Szadkowska, Dorota; Ołtarzewska, Alicja Małgorzata; Chlabicz, Sławomir

    2008-05-01

    Oral anticoagulants (OAC) are commonly used as a life-long therapy in prevention of systemic embolism in patients with atrial fibrillation, valvular heart disease and prosthetic hart valves and in the primary and secondary prevention of venous thromboembolism. They are also used for the prevention of thromboembolic events in patients with acute myocardial infarction and with angina pectoris, in patients with biological hart valves and after some types of orthopaedics surgery. The International Normalized Ratio (INR) is used to evaluate the efficacy of anti-coagulant therapy. The risk of thromboembolic and haemorrhagic complications increases when the INR is out of the therapeutic range. The aim of this study was to present information about the factors influencing activity of oral anticoagulants and interactions between oral anticoagulants and drugs or food. The effect of oral anticoagulants is influenced by genetic and environmental factors such as: medicines, food, diseases and pre-existing conditions. A common mutation in the gene coding for the cytochrome P450 (CYP2C9), with one or more combinations of its polymorphisms, is responsible for the reduced warfarin requirements or for the resistance to warfarin. A mutation in the factor IX is responsible for the risk of bleeding during OAC therapy without excessive prolongation of the prothrombin time (PT). Drugs, herbs and multivitamin supplements can alter the absorption, pharmacokinetics or pharmakodynamics of OAC. Nonsteroid anti-inflammatory drugs and paracetamol in combination with OAC seem to be the most dangerous because they are available without prescription and are used without medical consultation. Patients on OAC therapy are sensitive to changing dietary intake of vitamin K, which is supplied from phylloquinones in plants or from vitamin K-containing medicines. The effect of OAC can be influenced by other existing factors like: fever, diarrhoea, alcohol abuse or physical hyperactivity. Some malignancies

  3. Prosthetic Consideration in Implant-supported Prosthesis: A Review of Literature

    PubMed Central

    Gowd, Manga Snigdha; Shankar, Thatapudi; Ranjan, Rajeev; Singh, Arpita

    2017-01-01

    Modern dentistry has changed tremendously with implant therapy. For the successful implant therapy, making a proper treatment plan considering both surgical and prosthetic part in mind is the key of success. Often practitioners tend to create a treatment plan overlooking the basic principles of prosthetic part. This present review has discussed various prosthetic consideration of implant-supported prosthesis. A step-by-step detailed prosthetic option with their indications has been discussed to help all dental implant practitioners in making of an optimal treatment plan for each case. PMID:28713760

  4. 38 CFR 17.150 - Prosthetic and similar appliances.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... appliances. 17.150 Section 17.150 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS MEDICAL Prosthetic, Sensory, and Rehabilitative Aids § 17.150 Prosthetic and similar appliances... appliances including invalid lifts and therapeutic and rehabilitative devices, and special clothing made...

  5. Pre-prosthetic surgical alterations in maxillectomy to enhance the prosthetic prognoses as part of rehabilitation of oral cancer patient.

    PubMed

    El Fattah, H; Zaghloul, A; Pedemonte, E; Escuin, T

    2012-03-01

    After maxillectomy, prosthetic restoration of the resulting defect is an essential step because it signals the beginning of patient's rehabilitation. The obturator used to restore the defect should be comfortable, restore adequate speech, deglutition, mastication, and be cosmetically acceptable, success will depend on the size and location of the defect and the quantity and integrity of the remaining structures, in addition to pre-prosthetic surgical preparation of defect site. Preoperative cooperation between the oncologist surgeon and the maxillofacial surgeon may allow obturation of a resultant defect by preservation of the premaxilla or the tuberosity on the defect side and maintaining the alveolar bone or teeth adjacent to the defect. This study evaluates the importance of pre-prosthetic surgical alterations at the time maxillectomy on the enhancement of the prosthetic prognoses as part of the rehabilitation of oral cancer patient. The study was carried out between 2003- 2008, on 66 cancer patients(41 male-25 female) age ranged from 33 to 72 years, at National Cancer Institute, Cairo University, whom underwent maxillectomy surgery to remove malignant tumor as a part of cancer treatment. Patients were divided in two groups. Group A: Resection of maxilla followed by preprosthetic surgical preparation. Twenty-four cancer patients (13 male - 11 female). Group B: Resection of maxilla without any preprosthetic surgical preparation. Forty-two cancer patients (28 male-14 female). Outcome variables measured included facial contour and aesthetic results, speech understandability, ability to eat solid foods, oronasal separation, socializing outside the home, and return-to-work status. Flap success and donor site morbidity were also studied. To improve the prosthetic restoration of maxillary defect resulting maxillary resection as part treatment of maxillofacial tumor depends on the close cooperation between prosthodontist and surgeon, by combination of pre-prosthetic

  6. Rotationplasty with vascular reconstruction for prosthetic knee joint infection.

    PubMed

    Fujiki, Masahide; Miyamoto, Shimpei; Nakatani, Fumihiko; Kawai, Akira; Sakuraba, Minoru

    2015-01-01

    Rotationplasty is used most often as a function-preserving salvage procedure after resection of sarcomas of the lower extremity; however, it is also used after infection of prosthetic knee joints. Conventional vascular management during rotationplasty is to preserve and coil major vessels, but recently, transection and reanastomosis of the major vessels has been widely performed. However, there has been little discussion regarding the optimal vascular management of rotationplasty after infection of prosthetic knee joints because rotationplasty is rarely performed for this indication. We reviewed four patients who had undergone resection of osteosarcomas of the femur, placement of a prosthetic knee joint, and rotationplasty with vascular reconstruction from 2010 to 2013. The mean interval between prosthetic joint replacement and rotationplasty was 10.4 years and the mean interval between the diagnosis of prosthesis infection and rotationplasty was 7.9 years. Rotationplasty was successful in all patients; however, in one patient, arterial thrombosis developed and necessitated urgent surgical removal and arterial reconstruction. All patients were able to walk independently with a prosthetic limb after rehabilitation. Although there is no consensus regarding the most appropriate method of vascular management during rotationplasty for revision of infected prosthetic joints, vascular transection and reanastomosis is a useful option.

  7. Control System for Prosthetic Devices

    NASA Technical Reports Server (NTRS)

    Bozeman, Richard J. (Inventor)

    1996-01-01

    A control system and method for prosthetic devices is provided. The control system comprises a transducer for receiving movement from a body part for generating a sensing signal associated with that of movement. The sensing signal is processed by a linearizer for linearizing the sensing signal to be a linear function of the magnitude of the distance moved by the body part. The linearized sensing signal is normalized to be a function of the entire range of body part movement from the no-shrug position of the moveable body part through the full-shrg position of the moveable body part. The normalized signal is divided into a plurality of discrete command signals. The discrete command signals are used by typical converter devices which are in operational association with the prosthetic device. The converter device uses the discrete command signals for driving the moveable portions of the prosthetic device and its sub-prosthesis. The method for controlling a prosthetic device associated with the present invention comprises the steps of receiving the movement from the body part, generating a sensing signal in association with the movement of the body part, linearizing the sensing signal to be a linear function of the magnitude of the distance moved by the body part, normalizing the linear signal to be a function of the entire range of the body part movement, dividing the normalized signal into a plurality of discrete command signals, and implementing the plurality of discrete command signals for driving the respective moveable prosthesis device and its sub-prosthesis.

  8. Rehabilitation and Prosthetic Services

    MedlinePlus

    ... VA Learning University (VALU) SimLearn Libraries (VALNET) VA Software Documentation Library (VDL) About VHA Learn about VHA Forms & ... & Sensory Aids Service (PSAS) Our Mission The mission of the Prosthetic & ...

  9. Ten questions on prosthetic shoulder infection

    PubMed Central

    Pinder, Elizabeth M; Ong, Joshua CY; Bale, R Stephen

    2016-01-01

    Prosthetic shoulder infection can cause significant morbidity secondary to pain and stiffness. Symptoms may be present for years before diagnosis because clinical signs are often absent and inflammatory markers may be normal. An emerging common culprit, Propionibacterium acnes, is hard to culture and so prolonged incubation is necessary. A negative culture result does not always exclude infection and new synovial fluid biochemical markers such as α defensin are less sensitive than for lower limb arthroplasty. A structured approach is necessary when assessing patients for prosthetic shoulder joint infection. This includes history, examination, serum inflammatory markers, plain radiology and aspiration and/or biopsy. A classification for the likelihood of prosthetic shoulder infection has been described based on culture, pre-operative and intra-operative findings. Treatment options include antibiotic suppression, debridement with component retention, one-stage revision, two-stage revision and excision arthroplasty. Revision arthroplasty is associated with the best outcomes. PMID:27583013

  10. Ten questions on prosthetic shoulder infection.

    PubMed

    Pinder, Elizabeth M; Ong, Joshua Cy; Bale, R Stephen; Trail, Ian A

    2016-07-01

    Prosthetic shoulder infection can cause significant morbidity secondary to pain and stiffness. Symptoms may be present for years before diagnosis because clinical signs are often absent and inflammatory markers may be normal. An emerging common culprit, Propionibacterium acnes, is hard to culture and so prolonged incubation is necessary. A negative culture result does not always exclude infection and new synovial fluid biochemical markers such as α defensin are less sensitive than for lower limb arthroplasty. A structured approach is necessary when assessing patients for prosthetic shoulder joint infection. This includes history, examination, serum inflammatory markers, plain radiology and aspiration and/or biopsy. A classification for the likelihood of prosthetic shoulder infection has been described based on culture, pre-operative and intra-operative findings. Treatment options include antibiotic suppression, debridement with component retention, one-stage revision, two-stage revision and excision arthroplasty. Revision arthroplasty is associated with the best outcomes.

  11. Biomechanical characteristics, patient preference and activity level with different prosthetic feet: a randomized double blind trial with laboratory and community testing.

    PubMed

    Raschke, Silvia U; Orendurff, Michael S; Mattie, Johanne L; Kenyon, David E A; Jones, O Yvette; Moe, David; Winder, Lorne; Wong, Angie S; Moreno-Hernández, Ana; Highsmith, M Jason; J Sanderson, David; Kobayashi, Toshiki

    2015-01-02

    Providing appropriate prosthetic feet to those with limb loss is a complex and subjective process influenced by professional judgment and payer guidelines. This study used a small load cell (Europa™) at the base of the socket to measure the sagittal moments during walking with three objective categories of prosthetic feet in eleven individuals with transtibial limb loss with MFCL K2, K3 and K4 functional levels. Forefoot stiffness and hysteresis characteristics defined the three foot categories: Stiff, Intermediate, and Compliant. Prosthetic feet were randomly assigned and blinded from participants and investigators. After laboratory testing, participants completed one week community wear tests followed by a modified prosthetics evaluation questionnaire to determine if a specific category of prosthetic feet was preferred. The Compliant category of prosthetic feet was preferred by the participants (P=0.025) over the Stiff and Intermediate prosthetic feet, and the Compliant and Intermediate feet had 15% lower maximum sagittal moments during walking in the laboratory (P=0.0011) compared to the Stiff feet. The activity level of the participants did not change significantly with any of the wear tests in the community, suggesting that each foot was evaluated over a similar number of steps, but did not inherently increase activity. This is the first randomized double blind study in which prosthetic users have expressed a preference for a specific biomechanical characteristic of prosthetic feet: those with lower peak sagittal moments were preferred, and specifically preferred on slopes, stairs, uneven terrain, and during turns and maneuvering during real world use. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  12. Prosthetic Device Infections.

    PubMed

    Martinez, Raquel M; Bowen, Thomas R; Foltzer, Michael A

    2016-08-01

    The immunocompromised host is a particularly vulnerable population in whom routine and unusual infections can easily and frequently occur. Prosthetic devices are commonly used in these patients and the infections associated with those devices present a number of challenges for both the microbiologist and the clinician. Biofilms play a major role in device-related infections, which may contribute to failed attempts to recover organisms from routine culture methods. Moreover, device-related microorganisms can be difficult to eradicate by antibiotic therapy alone. Changes in clinical practice and advances in laboratory diagnostics have provided significant improvements in the detection and accurate diagnosis of device-related infections. Disruption of the bacterial biofilm plays an essential role in recovering the causative agent in culture. Various culture and nucleic acid amplification techniques are more accurate to guide directed treatment regimens. This chapter reviews the performance characteristics of currently available diagnostic assays and summarizes published guidelines, where available, for addressing suspected infected prosthetic devices.

  13. Beyond war and military medicine: social factors in the development of prosthetics.

    PubMed

    Reznick, Jeffrey S

    2008-01-01

    Polytrauma is an immediate outcome of current warfare, and the need to investigate this condition is equally immediate. The value of historical analysis in this endeavor should not be underestimated. It is among the best tools we have to help ensure that current research and practice involve engagement with the social contexts of polytrauma as well as with the medical science of its treatment. This special communication provides historical perspective on certain aspects of the polytraumatic condition--namely, limb loss, prosthetic rehabilitation, and community reintegration after receiving a prosthesis. It discusses the influential role of societal factors in these areas to encourage greater understanding that the care of persons with polytrauma must involve critical thinking about their relationships to and participation in society as well as their treatment by medical science. This special communication also provides historical perspective to enrich appreciation of the value of history for the field of physical medicine and rehabilitation (PM&R), the PM&R clinician, and the PM&R clinical researcher. Readers will learn that historical knowledge puts PM&R research and practice into perspective, reminding us that rehabilitation should involve critical thinking not only about medicine, but also about social roles and the participation of people in society despite physical and psychologic challenges.

  14. Risk Factors for Prosthetic Pulmonary Valve Failure in Patients With Congenital Heart Disease.

    PubMed

    Oliver, Jose Maria; Garcia-Hamilton, Diego; Gonzalez, Ana Elvira; Ruiz-Cantador, Jose; Sanchez-Recalde, Angel; Polo, Maria Luz; Aroca, Angel

    2015-10-15

    The incidence and risk factors for prosthetic pulmonary valve failure (PPVF) should be considered when determining optimal timing for pulmonary valve replacement (PVR) in asymptomatic patients with congenital heart disease (CHD). The cumulative freedom for reintervention due to PPVF after 146 PVR in 114 patients with CHD was analyzed. Six potential risk factors (underlying cardiac defect, history of palliative procedures, number of previous cardiac interventions, hemodynamic indication for PVR, type of intervention, and age at intervention) were analyzed using Cox proportional hazard modeling. Receiver operating characteristic (ROC) curves were used for discrimination. Internal validation in patients with tetralogy of Fallot was also performed. Median age at intervention was 23 years. There were 60 reinterventions due to PPVF (41%). Median event-free survival was 14 years (95% confidence interval [CI] 12 to 16 years). The only independent risk factor was the age at intervention (hazard ratio [HR] 0.93, 95% CI 0.90 to 0.97; p = 0.001; area under the ROC curve 0.95, 95% CI 0.92 to 0.98; p <0.001). The best cut-off point was 20.5 years. Freedom from reintervention for PPVF 15 years after surgery was 70% when it was performed at age >20.5 years compared with 33% when age at intervention was <20.5 years (p = 0.004). Internal validation in 102 PVR in patient cohort with tetralogy of Fallot (ROC area 0.98, 95% CI 0.96 to 1.0; p <0.001) was excellent. In conclusion, age at intervention is the main risk factor of reintervention for PPVF. The risk of reintervention is 2-fold when PVR is performed before the age of 20.5 years. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. 21 CFR 890.3420 - External limb prosthetic component.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false External limb prosthetic component. 890.3420 Section 890.3420 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3420...

  16. 21 CFR 890.3025 - Prosthetic and orthotic accessory.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Prosthetic and orthotic accessory. 890.3025 Section 890.3025 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3025...

  17. 21 CFR 890.3025 - Prosthetic and orthotic accessory.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Prosthetic and orthotic accessory. 890.3025 Section 890.3025 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3025...

  18. 21 CFR 890.3025 - Prosthetic and orthotic accessory.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Prosthetic and orthotic accessory. 890.3025 Section 890.3025 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3025...

  19. 21 CFR 890.3420 - External limb prosthetic component.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false External limb prosthetic component. 890.3420 Section 890.3420 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3420...

  20. 21 CFR 890.3420 - External limb prosthetic component.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false External limb prosthetic component. 890.3420 Section 890.3420 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3420...

  1. 21 CFR 890.3025 - Prosthetic and orthotic accessory.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Prosthetic and orthotic accessory. 890.3025 Section 890.3025 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3025...

  2. 21 CFR 890.3420 - External limb prosthetic component.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false External limb prosthetic component. 890.3420 Section 890.3420 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3420...

  3. 21 CFR 890.3420 - External limb prosthetic component.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false External limb prosthetic component. 890.3420 Section 890.3420 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3420...

  4. 21 CFR 890.3025 - Prosthetic and orthotic accessory.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Prosthetic and orthotic accessory. 890.3025 Section 890.3025 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3025...

  5. Undergraduate prosthetics and orthotics teaching methods: A baseline for international comparison.

    PubMed

    Aminian, Gholamreza; O'Toole, John M; Mehraban, Afsoon Hassani

    2015-08-01

    Education of Prosthetics and Orthotics is a relatively recent professional program. While there has been some work on various teaching methods and strategies in international medical education, limited publication exists within prosthetics and orthotics. To identify the teaching and learning methods that are used in Bachelor-level prosthetics and orthotics programs that are given highest priority by expert prosthetics and orthotics instructors from regions enjoying a range of economic development. Mixed method. The study partly documented by this article utilized a mixed method approach (qualitative and quantitative methods) within which each phase provided data for other phases. It began with analysis of prosthetics and orthotics curricula documents, which was followed by a broad survey of instructors in this field and then a modified Delphi process. The expert instructors who participated in this study gave high priority to student-centered, small group methods that encourage critical thinking and may lead to lifelong learning. Instructors from more developed nations placed higher priority on student's independent acquisition of prosthetics and orthotics knowledge, particularly in clinical training. Application of student-centered approaches to prosthetics and orthotics programs may be preferred by many experts, but there appeared to be regional differences in the priority given to different teaching methods. The results of this study identify the methods of teaching that are preferred by expert prosthetics and orthotics instructors from a variety of regions. This treatment of current instructional techniques may inform instructor choice of teaching methods that impact the quality of education and improve the professional skills of students. © The International Society for Prosthetics and Orthotics 2014.

  6. [Localized purpura revealing vascular prosthetic graft infection].

    PubMed

    Boureau, A S; Lescalie, F; Cassagnau, E; Clairand, R; Connault, J

    2013-07-01

    Prosthetic graft infection after vascular reconstruction is a rare but serious complication. We report a case of infection occurring late after implantation of an iliofemoral prosthetic vascular graft. The Staphylococcus aureus infection was revealed by vascular purpura localized on the right leg 7 years after implantation of a vascular prosthesis. This case illustrates an uncommonly late clinical manifestation presenting as an acute infection 7 years after the primary operation. In this situation, the presentation differs from early infection, which generally occurs within the first four postoperative months. Diagnosis and treatment remain a difficult challenge because prosthetic graft infection is a potentially life-threatening complication. Morbidity and mortality rates are high. Here we detail specific aspects of the clinical and radiological presentation. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  7. The influence of a hydraulic prosthetic ankle on residual limb loading during sloped walking

    PubMed Central

    Nickel, Eric A.; Medvec, Joseph; Barrons, Kyle; Mion, Spencer; Hansen, Andrew H.

    2017-01-01

    In recent years, numerous prosthetic ankle-foot devices have been developed to address the demands of sloped walking for individuals with lower-limb amputation. The goal of this study was to compare the performance of a passive, hydraulic ankle-foot prosthesis to two related, non-hydraulic ankles based on their ability to minimize the socket reaction moments of individuals with transtibial amputation during a range of sloped walking tasks. After a two-week accommodation period, kinematic data were collected on seven subjects with a transtibial amputation walking on an instrumented treadmill set at various slopes. Overall, this study was unable to find significant differences in the torque at the distal end of the prosthetic socket between an ankle-foot prosthesis with a hydraulic range-of-motion and other related ankle-foot prosthesis designs (rigid ankle, multiaxial ankle) during the single-support phase of walking. In addition, socket comfort and perceived exertion were not significantly different for any of the ankle-foot prostheses tested in this study. These results suggest the need for further work to determine if more advanced designs (e.g., those with microprocessor control of hydraulic features, powered ankle-foot designs) can provide more biomimetic function to prosthesis users. PMID:28278172

  8. Salmonella Typhimurium gastroenteritis leading to chronic prosthetic vascular graft infection.

    PubMed

    Cullinan, Milo; Clarke, Michael; Dallman, Tim; Peart, Steven; Wilson, Deborah; Weiand, Daniel

    2017-08-01

    Introduction. It is estimated up to 6 % of prosthetic vascular grafts become infected. Staphylococcus aureus is predominant in early infection and coagulase-negative staphylococci are predominant in late infections. Enterobacteriaceae cause 14-40 % of prosthetic vascular graft infections. This is, to our knowledge the first reported case of Salmonella gastroenteritis causing chronic prosthetic vascular graft infection (PVGI). Case presentation. A 57 years old lady presented with signs and symptoms of prosthetic vascular graft infection. Three years earlier, she had undergone a prosthetic axillo-femoral bypass graft for critical limb ischaemia. The infected prosthetic vascular graft was removed and Salmonella Typhimurium was isolated on culture. In the intervening period, Salmonella Typhimurium was isolated from a faecal specimen, collected during an episode of acute gastroenteritis. Whole-genome sequencing (WGS) showed that the respective Salmonella Typhimurium isolates differed by only a single nucleotide polymorphism (SNP). Salmonella Typhimurium was not isolated on culture of a faecal specimen collected five days following cessation of antimicrobial therapy. Six months after removal of the prosthetic graft, the patient remains under follow-up for her peripheral vascular disease, which currently requires no further surgical intervention. Conclusion. This case has clear implications for the management of chronic PVGI. It is vital to collect high-quality surgical specimens for microbiological analysis and empirical choices of antibiotics are unlikely to cover all potential pathogens. It may also be prudent to enquire about a history of acute gastroenteritis when assessing patients presenting with chronic PVGI.

  9. Prosthetic Tool For Holding Small Ferromagnetic Parts

    NASA Technical Reports Server (NTRS)

    Norton, William E.; Carden, James R.; Belcher, Jewell G., Jr.; Vest, Thomas W.

    1995-01-01

    Tool attached to prosthetic hand or arm enables user to hold nails, screws, nuts, rivets, and other small ferromagnetic objects on small magnetic tip. Device adjusted to hold nail or screw at proper angle for hammering or for use of screwdriver, respectively. Includes base connector with threaded outer surface and lower male member inserted in standard spring-action, quick-connect/quick-disconnect wrist adapter on prosthetic hand or arm.

  10. Provision of Prosthetic Services Following Lower Limb Amputation in Malaysia

    PubMed Central

    Arifin, Nooranida; Hasbollah, Hasif Rafidee; Hanafi, Muhammad Hafiz; Ibrahim, Al Hafiz; Rahman, Wan Afezah Wan Abdul; Aziz, Roslizawati Che

    2017-01-01

    The incidence of lower limb amputation is high across the globe and continues to be a major threat to morbidity and mortality. Consequently, the provision of high quality and effective prosthetics services have been known as an essential component for a successful rehabilitation outcome. In Malaysia, amputation prevalence has been increasing in which several main components of service delivering aspects (such as service intervention, prosthetic personnel) should be anticipated to accommodate for the increasing demand. This article highlights the hurdles experienced in providing prosthetic services in Malaysia from multiple aspects such as financial burden to acquire the prosthesis and lack of expertise to produce quality prosthesis. This paramount issues consequently justify for the urgency to carry out national level survey on the current statistics of lower limb amputation and to ascertain the available workforce to provide a quality prosthetics services. Only with accurate and current information from the national survey, strategies and policies aimed at enhancing the outcome from prosthetics services can be achieved. PMID:29386978

  11. Provision of Prosthetic Services Following Lower Limb Amputation in Malaysia.

    PubMed

    Arifin, Nooranida; Hasbollah, Hasif Rafidee; Hanafi, Muhammad Hafiz; Ibrahim, Al Hafiz; Rahman, Wan Afezah Wan Abdul; Aziz, Roslizawati Che

    2017-10-01

    The incidence of lower limb amputation is high across the globe and continues to be a major threat to morbidity and mortality. Consequently, the provision of high quality and effective prosthetics services have been known as an essential component for a successful rehabilitation outcome. In Malaysia, amputation prevalence has been increasing in which several main components of service delivering aspects (such as service intervention, prosthetic personnel) should be anticipated to accommodate for the increasing demand. This article highlights the hurdles experienced in providing prosthetic services in Malaysia from multiple aspects such as financial burden to acquire the prosthesis and lack of expertise to produce quality prosthesis. This paramount issues consequently justify for the urgency to carry out national level survey on the current statistics of lower limb amputation and to ascertain the available workforce to provide a quality prosthetics services. Only with accurate and current information from the national survey, strategies and policies aimed at enhancing the outcome from prosthetics services can be achieved.

  12. 21 CFR 870.3935 - Prosthetic heart valve holder.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Prosthetic heart valve holder. 870.3935 Section... heart valve holder. (a) Identification. A prosthetic heart valve holder is a device used to hold a replacement heart valve while it is being sutured into place. (b) Classification. Class I. The device is...

  13. 21 CFR 870.3935 - Prosthetic heart valve holder.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Prosthetic heart valve holder. 870.3935 Section... heart valve holder. (a) Identification. A prosthetic heart valve holder is a device used to hold a replacement heart valve while it is being sutured into place. (b) Classification. Class I. The device is...

  14. 21 CFR 870.3935 - Prosthetic heart valve holder.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Prosthetic heart valve holder. 870.3935 Section... heart valve holder. (a) Identification. A prosthetic heart valve holder is a device used to hold a replacement heart valve while it is being sutured into place. (b) Classification. Class I. The device is...

  15. 21 CFR 870.3935 - Prosthetic heart valve holder.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Prosthetic heart valve holder. 870.3935 Section... heart valve holder. (a) Identification. A prosthetic heart valve holder is a device used to hold a replacement heart valve while it is being sutured into place. (b) Classification. Class I. The device is...

  16. 21 CFR 870.3935 - Prosthetic heart valve holder.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Prosthetic heart valve holder. 870.3935 Section... heart valve holder. (a) Identification. A prosthetic heart valve holder is a device used to hold a replacement heart valve while it is being sutured into place. (b) Classification. Class I. The device is...

  17. Characterisation of prosthetic feet used in low-income countries.

    PubMed

    Sam, M; Hansen, A H; Childress, D S

    2004-08-01

    Eleven kinds of prosthetic feet that were designed for use in low-income countries were mechanically characterised in this study. Masses of the different kinds of prosthetic feet varied substantially. Dynamic properties, including damping ratios and resonant frequencies, were obtained from step unloading tests of the feet while interacting with masses comparable to the human body. Data showed that for walking, the feet can be appropriately modeled using their quasistatic properties since natural frequencies were high compared to walking frequencies and since damping ratios were small. Roll-over shapes, the effective rocker (cam) geometries that the feet deform to under walking loads, were determined using a quasistatic loading technique and a spatial transformation of the ground reaction force's centre of pressure. The roll-over shapes for most of the prosthetic feet studied were similar to the roll-over shape of the SACH (solid-ankle cushioned heel) prosthetic foot. All roll-over shapes showed a lack of forefoot support, which may cause a "drop-off" experience at the end of single limb stance and shorter step lengths of the contralateral limb. The roll-over shapes of prosthetic feet appear useful in characterization of foot function.

  18. Comparison of prosthetic feet prescribed to active individuals using ISO standards.

    PubMed

    Mason, Zachary D; Pearlman, Jon; Cooper, Rory A; Laferrier, Justin Z

    2011-12-01

    Little research has been done on the robustness of prosthetic feet prescribed to military personnel, and manufacturers are not required to test their products prior to sale. This is problematic because the prosthetic feet used by active individuals are subjected to loading conditions not seen in normal gait. To evaluate whether commercially available heavy-duty prosthetic feet intended for use by military personnel meet ISO 10328 standards. Bench testing of heavy-duty prosthetic feet using ISO 10328 standards. Prosthetic feet from three different manufacturers were tested according to ISO 10328 standards, using a testing frame fitted with axial load and displacement transducers. Pass/fail information was recorded as well as the stiffness and creep of each foot before and after cyclic testing. All feet passed the ISO 10328 standards at the highest loading level, and some significant differences were found within a given model of prosthesis when comparing stiffness and creep before and after cyclic testing. This study demonstrated that manufacturers of heavy-duty prosthetic feet adhere to the voluntary ISO 10328 standards. However, these standards may be insufficient because the tests simulate only idealized gait. Further development of the standards may be necessary to reproduce the circumstances that occur during extreme usage to ensure that prosthetic feet do not fail.

  19. Is Asymptomatic Bacteriuria a Risk Factor for Prosthetic Joint Infection?

    PubMed Central

    Sousa, Ricardo; Muñoz-Mahamud, Ernesto; Quayle, Jonathan; Dias da Costa, Luis; Casals, Cristina; Scott, Phylip; Leite, Pedro; Vilanova, Paz; Garcia, Sebastian; Ramos, Maria Helena; Dias, Joana; Soriano, Alex; Guyot, Andrea

    2014-01-01

    Background. Infection is a major complication after total joint arthroplasty. The urinary tract is a possible source of surgical site contamination, but the role of asymptomatic bacteriuria (ASB) before elective surgery and the subsequent risk of infection is poorly understood. Methods. Candidates for total hip or total knee arthroplasty were reviewed in a multicenter cohort study. A urine sample was cultured in all patients, and those with ASB were identified. Preoperative antibiotic treatment was decided on an individual basis, and it was not mandatory or randomized. The primary outcome was prosthetic joint infection (PJI) in the first postoperative year. Results. A total of 2497 patients were enrolled. The prevalence of ASB was 12.1% (303 of 2497), 16.3% in women and 5.0% in men (odds ratio, 3.67; 95% confidence interval, 2.65–5.09; P < .001). The overall PJI rate was 1.7%. The infection rate was significantly higher in the ASB group than in the non-ASB group (4.3% vs 1.4%; odds ratio, 3.23; 95% confidence interval, 1.67–6.27; P = .001). In the ASB group, there was no significant difference in PJI rate between treated (3.9%) and untreated (4.7%) patients. The ASB group had a significantly higher proportion of PJI due to gram-negative microorganisms than the non-ASB group, but these did not correlate to isolates from urine cultures. Conclusions. ASB was an independent risk factor for PJI, particularly that due to gram-negative microorganisms. Preoperative antibiotic treatment did not show any benefit and cannot be recommended. PMID:24723280

  20. Mechanical design and performance specifications of anthropomorphic prosthetic hands: a review.

    PubMed

    Belter, Joseph T; Segil, Jacob L; Dollar, Aaron M; Weir, Richard F

    2013-01-01

    In this article, we set forth a detailed analysis of the mechanical characteristics of anthropomorphic prosthetic hands. We report on an empirical study concerning the performance of several commercially available myoelectric prosthetic hands, including the Vincent, iLimb, iLimb Pulse, Bebionic, Bebionic v2, and Michelangelo hands. We investigated the finger design and kinematics, mechanical joint coupling, and actuation methods of these commercial prosthetic hands. The empirical findings are supplemented with a compilation of published data on both commercial and prototype research prosthetic hands. We discuss numerous mechanical design parameters by referencing examples in the literature. Crucial design trade-offs are highlighted, including number of actuators and hand complexity, hand weight, and grasp force. Finally, we offer a set of rules of thumb regarding the mechanical design of anthropomorphic prosthetic hands.

  1. Simulation of a sensor array for multiparameter measurements at the prosthetic limb interface

    NASA Astrophysics Data System (ADS)

    Rowe, Gabriel I.; Mamishev, Alexander V.

    2004-07-01

    Sensitive skin is a highly desired device for biomechanical devices, wearable computing, human-computer interfaces, exoskeletons, and, most pertinent to this paper, for lower limb prosthetics. The measurement of shear stress is very important because shear effects are key factors in developing surface abrasions and pressure sores in paraplegics and users of prosthetic/orthotic devices. A single element of a sensitive skin is simulated and characterized in this paper. Conventional tactile sensors are designed for measurement of the normal stress only, which is inadequate for comprehensive assessment of surface contact conditions. The sensitive skin discussed here is a flexible array capable of sensing shear and normal forces, as well as humidity and temperature on each element.

  2. Prosthetic elbow joint

    NASA Technical Reports Server (NTRS)

    Weddendorf, Bruce C. (Inventor)

    1994-01-01

    An artificial, manually positionable elbow joint for use in an upper extremity, above-elbow, prosthetic is described. The prosthesis provides a locking feature that is easily controlled by the wearer. The instant elbow joint is very strong and durable enough to withstand the repeated heavy loadings encountered by a wearer who works in an industrial, construction, farming, or similar environment. The elbow joint of the present invention comprises a turntable, a frame, a forearm, and a locking assembly. The frame generally includes a housing for the locking assembly and two protruding ears. The forearm includes an elongated beam having a cup-shaped cylindrical member at one end and a locking wheel having a plurality of holes along a circular arc on its other end with a central bore for pivotal attachment to the protruding ears of the frame. The locking assembly includes a collar having a central opening with a plurality of internal grooves, a plurality of internal cam members each having a chamfered surface at one end and a V-shaped slot at its other end; an elongated locking pin having a crown wheel with cam surfaces and locking lugs secured thereto; two coiled compression springs; and a flexible filament attached to one end of the elongated locking pin and extending from the locking assembly for extending and retracting the locking pin into the holes in the locking wheel to permit selective adjustment of the forearm relative to the frame. In use, the turntable is affixed to the upper arm part of the prosthetic in the conventional manner, and the cup-shaped cylindrical member on one end of the forearm is affixed to the forearm piece of the prosthetic in the conventional manner. The elbow joint is easily adjusted and locked between maximum flex and extended positions.

  3. Three-Dimensional Printing of Prosthetic Hands for Children.

    PubMed

    Burn, Matthew B; Ta, Anderson; Gogola, Gloria R

    2016-05-01

    Children with hand reductions, whether congenital or traumatic, have unique prosthetic needs. They present a challenge because of their continually changing size due to physical growth as well as changing needs due to psychosocial development. Conventional prosthetics are becoming more technologically advanced and increasingly complex. Although these are welcome advances for adults, the concomitant increases in weight, moving parts, and cost are not beneficial for children. Pediatric prosthetic needs may be better met with simpler solutions. Three-dimensional printing can be used to fabricate rugged, light-weight, easily replaceable, and very low cost assistive hands for children. Copyright © 2016 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  4. Rotationally Actuated Prosthetic Hand

    NASA Technical Reports Server (NTRS)

    Norton, William E.; Belcher, Jewell G., Jr.; Carden, James R.; Vest, Thomas W.

    1991-01-01

    Prosthetic hand attached to end of remaining part of forearm and to upper arm just above elbow. Pincerlike fingers pushed apart to degree depending on rotation of forearm. Simpler in design, simpler to operate, weighs less, and takes up less space.

  5. Periprosthetic joint infection: are patients with multiple prosthetic joints at risk?

    PubMed

    Jafari, S Mehdi; Casper, David S; Restrepo, Camilo; Zmistowski, Benjamin; Parvizi, Javad; Sharkey, Peter F

    2012-06-01

    Patients who present with a periprosthetic joint infection in a single joint may have multiple prosthetic joints. The risk of these patients developing a subsequent infection in another prosthetic joint is unknown. Our purposes were (1) to identify the risk of developing a subsequent infection in another prosthetic joint and (2) to describe the time span and organism profile to the second prosthetic infection. We retrospectively identified 55 patients with periprosthetic joint infection who had another prosthetic joint in place at the time of presentation. Of the 55 patients, 11 (20%) developed a periprosthetic joint infection in a second joint. The type of organism was the same as the first infection in 4 (36%) of 11 patients. The time to developing a second infection averaged 2.0 years (range, 0-6.9 years). Copyright © 2012 Elsevier Inc. All rights reserved.

  6. Radiographic parameters improve lower extremity prosthetic alignment.

    PubMed

    Mooney, Ryan; Carry, Patrick; Wylie, Erin; Schultz, Abby; McNair, Bryan; Page, Carol; Biffl, Susan; Heare, Travis

    2013-12-01

    The goal of prosthetic fitting is to provide comfort and functionality to the patient. It is thought that incorporating the use of standing anterior-posterior long leg radiographs (LLR) into the fitting of lower extremity prostheses will provide an objective guide when making adjustments, and be a better assessment of alignment. This study compares prosthetic alignment before and after radiography-guided adjustments. This retrospective study was performed at a multidisciplinary amputee clinic on patients with congenital and/or acquired limb deficiencies. Their prosthetic alignment was evaluated by LLR and adjusted as needed. Satisfactory alignment was defined as a mechanical axis angular deviation of ≤1° and a leg length discrepancy of ≤10 mm. A total of 45 unique prostheses from 24 subjects (10 female and 14 male) were included. Post-adjustment radiographs were obtained from 29 prostheses. After the initial prosthetic fitting, the probability of a satisfactory fit was 20.0 % (95 % CI 10.9-34.9 %). Following the baseline adjustment, the probability of a satisfactory fit improved to 53.3 % (95 % CI 37.5-70.9 %). After adjustment number 4, the probability of a satisfactory fit further improved to 76.7 % (95 % CI 41.9-98.0 %). There were also significant improvements in distal offset distance (p = 0.0040) and leg length discrepancy (p = 0.0206). The distal offset distance decreased by an average of 10.7 mm (95 % CI 3.6-17.8), and leg length discrepancy decreased by an average of 3.0 mm (95 % CI 00.48-5.5). The addition of LLRs to existing fitting methods significantly improves prosthetic alignment and length.

  7. Custom-made laser-welded titanium implant prosthetic abutment.

    PubMed

    Iglesia-Puig, Miguel A

    2005-10-01

    A technique to create an individually modified implant prosthetic abutment is described. An overcasting is waxed onto a machined titanium abutment, cast in titanium, and joined to it with laser welding. With the proposed technique, a custom-made titanium implant prosthetic abutment is created with adequate volume and contour of metal to support a screw-retained, metal-ceramic implant-supported crown.

  8. 75 FR 52629 - Medicare Program; Establishing Additional Medicare Durable Medical Equipment, Prosthetics...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-27

    ... wheelchairs. Prosthetic devices are included in the definition of ``medical and other health services'' under section 1861(s)(8) of the Act. Prosthetic devices are defined in this section of the Act as ``devices... insertion of an intraocular lens.'' Other examples of prosthetic devices include cardiac pacemakers...

  9. Mesofluidic controlled robotic or prosthetic finger

    DOEpatents

    Lind, Randall F; Jansen, John F; Love, Lonnie J

    2013-11-19

    A mesofluidic powered robotic and/or prosthetic finger joint includes a first finger section having at least one mesofluidic actuator in fluid communication with a first actuator, a second mesofluidic actuator in fluid communication with a second actuator and a second prosthetic finger section pivotally connected to the first finger section by a joint pivot, wherein the first actuator pivotally cooperates with the second finger to provide a first mechanical advantage relative to the joint point and wherein the second actuator pivotally cooperates with the second finger section to provide a second mechanical advantage relative to the joint point.

  10. Rotational joint assembly for the prosthetic leg

    NASA Technical Reports Server (NTRS)

    Owens, L. J.; Jones, W. C. (Inventor)

    1977-01-01

    A rotational joint assembly for a prosthetic leg has been devised, which enables an artificial foot to rotate slightly when a person is walking, running or turning. The prosthetic leg includes upper and lower tubular members with the rotational joint assembly interposed between them. The assembly includes a restrainer mechanism which consists of a pivotably mounted paddle element. This device applies limiting force to control the rotation of the foot and also restores torque to return the foot back to its initial position.

  11. Prosthetic model, but not stiffness or height, affects the metabolic cost of running for athletes with unilateral transtibial amputations.

    PubMed

    Beck, Owen N; Taboga, Paolo; Grabowski, Alena M

    2017-07-01

    Running-specific prostheses enable athletes with lower limb amputations to run by emulating the spring-like function of biological legs. Current prosthetic stiffness and height recommendations aim to mitigate kinematic asymmetries for athletes with unilateral transtibial amputations. However, it is unclear how different prosthetic configurations influence the biomechanics and metabolic cost of running. Consequently, we investigated how prosthetic model, stiffness, and height affect the biomechanics and metabolic cost of running. Ten athletes with unilateral transtibial amputations each performed 15 running trials at 2.5 or 3.0 m/s while we measured ground reaction forces and metabolic rates. Athletes ran using three different prosthetic models with five different stiffness category and height combinations per model. Use of an Ottobock 1E90 Sprinter prosthesis reduced metabolic cost by 4.3 and 3.4% compared with use of Freedom Innovations Catapult [fixed effect (β) = -0.177; P < 0.001] and Össur Flex-Run (β = -0.139; P = 0.002) prostheses, respectively. Neither prosthetic stiffness ( P ≥ 0.180) nor height ( P = 0.062) affected the metabolic cost of running. The metabolic cost of running was related to lower peak (β = 0.649; P = 0.001) and stance average (β = 0.772; P = 0.018) vertical ground reaction forces, prolonged ground contact times (β = -4.349; P = 0.012), and decreased leg stiffness (β = 0.071; P < 0.001) averaged from both legs. Metabolic cost was reduced with more symmetric peak vertical ground reaction forces (β = 0.007; P = 0.003) but was unrelated to stride kinematic symmetry ( P ≥ 0.636). Therefore, prosthetic recommendations based on symmetric stride kinematics do not necessarily minimize the metabolic cost of running. Instead, an optimal prosthetic model, which improves overall biomechanics, minimizes the metabolic cost of running for athletes with unilateral transtibial amputations. NEW & NOTEWORTHY The metabolic cost of running for

  12. Embodied prosthetic arm stabilizes body posture, while unembodied one perturbs it.

    PubMed

    Imaizumi, Shu; Asai, Tomohisa; Koyama, Shinichi

    2016-10-01

    Senses of ownership (this arm belongs to me) and agency (I am controlling this arm) originate from sensorimotor system. External objects can be integrated into the sensorimotor system following long-term use, and recognized as one's own body. We examined how an (un)embodied prosthetic arm modulates whole-body control, and assessed the components of prosthetic embodiment. Nine unilateral upper-limb amputees participated. Four frequently used their prosthetic arm, while the others rarely did. Their postural sway was measured during quiet standing with or without their prosthesis. The frequent users showed greater sway when they removed the prosthesis, while the rare users showed greater sway when they fitted the prosthesis. Frequent users reported greater everyday feelings of postural stabilization by prosthesis and a larger sense of agency over the prosthesis. We suggest that a prosthetic arm maintains or perturbs postural control, depending on the prosthetic embodiment, which involves sense of agency rather than ownership. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Historical Aspects of Inner Ear Anatomy and Biology that Underlie the Design of Hearing and Balance Prosthetic Devices.

    PubMed

    Van De Water, Thomas R

    2012-11-01

    This review presents some of the major historical events that advanced the body of knowledge of the anatomy of the inner ear and its sensory receptors as well as the biology of these receptors that underlies the sensory functions of hearing and balance. This knowledge base of the inner ear's structure/function has been an essential factor for the design and construction of prosthetic devices to aid patients with deficits in their senses of hearing and balance. Prosthetic devices are now available for severely hearing impaired and deaf patients to restore hearing and are known as cochlear implants and auditory brain stem implants. A prosthetic device for patients with balance disorders is being perfected and is in an animal model testing phase with another prosthetic device for controlling intractable dizziness in Meniere's patients currently being evaluated in clinical testing. None of this would have been possible without the pioneering studies and discoveries of the investigators mentioned in this review and with the work of many other talented investigators to numerous to be covered in this review. Copyright © 2012 Wiley Periodicals, Inc.

  14. Cost analysis of debridement and retention for management of prosthetic joint infection.

    PubMed

    Peel, T N; Dowsey, M M; Buising, K L; Liew, D; Choong, P F M

    2013-02-01

    Prosthetic joint infection remains one of the most devastating complications of arthroplasty. Debridement and retention of the prosthesis is an attractive management option in carefully selected patients. Despite this, there are no data investigating the cost of this management modality for prosthetic joint infections. The aim of this case-control study was to calculate the cost associated with debridement and retention for management of prosthetic joint infection compared with primary joint replacement surgery without prosthetic joint infection. From 1 January 2008 to 30 June 2010, there were 21 prosthetic joint infections matched to 42 control patients. Controls were matched to cases according to the arthroplasty site, age and sex. Cases had a greater number of unplanned readmissions (100% vs. 7.1%; p <0.001), more additional surgery (3.3 vs. 0.07; p <0.001) and longer total bed days (31.6 vs. 7.9 days; p <0.001). In addition they had more inpatient, outpatient and emergency department visits (p <0.001, respectively). For patients with prosthetic joint infection the total cost, including index operation and costs of management of the prosthetic joint infection, was 3.1 times the cost of primary arthoplasty; the mean cost for cases was Australian dollars (AUD) $69,414 (±29,869) compared with $22,085 (±8147) (p <0.001). The demand for arthroplasty continues to grow and with that, the number of prosthetic joint infections will also increase, placing significant burden on the health system. Our study adds significantly to the growing body of evidence highlighting the substantial costs associated with prosthetic joint infection. © 2011 The Authors. Clinical Microbiology and Infection © 2011 European Society of Clinical Microbiology and Infectious Diseases.

  15. An evaluation of dental prosthetic status and prosthetic needs among eunuchs (trans genders) residing in bhopal city, madhya pradesh, India: a cross-sectional study.

    PubMed

    Hongal, S; Torwane, Na; Chandrashekhar, Br; Saxena, V; Chavan, Kr

    2014-11-01

    Eunuchs are considered as the most vulnerable, frustrated, and insecure community. The accessibility to medical and dental facilities for the eunuchs is nearly nonexistent. Due to these reasons, they might be at a high risk of developing severe dental problems like tooth loss. The present cross-sectional study aimed to evaluate the dental prosthetic status and prosthetic needs among eunuchs residing in Bhopal city, Madhya Pradesh, India. On the basis of convenient nonprobability snowball sampling technique, all the self-identified eunuchs residing in the city of Bhopal along with a matched control consisting of cross section of the general population residing in the same locality was examined to evaluate the prosthetic status and prosthetic needs of the population. All the obtained data were entered into a personal computer on Microsoft excel sheet and analyzed using the software; Statistical Package for Social Science version 20. Data comparison was done by applying Chi-square test. A total of 639 subjects comprised of 207 eunuchs, 218 males and 214 females. Among all participants, 2.8% (18/639) were having prosthesis. The overall prosthetic status among males was 3.2% (7/218) followed by 2.9% (6/207) eunuchs and 2.3% (5/214) females. However, need for multi-unit and combination of one and more unit prosthesis for upper and lower jaws was higher in males compared to females and eunuchs, but the difference was not statistically significant. The findings of this study clearly demonstrate a high unmet need for prosthetic care among the population surveyed.

  16. Prosthetic Mitral Valve Leaflet Escape

    PubMed Central

    Kim, Darae; Hun, Sin Sang; Cho, In-Jeong; Shim, Chi-Young; Ha, Jong-Won; Chung, Namsik; Ju, Hyun Chul; Sohn, Jang Won

    2013-01-01

    Leaflet escape of prosthetic valve is rare but potentially life threatening. It is essential to make timely diagnosis in order to avoid mortality. Transesophageal echocardiography and cinefluoroscopy is usually diagnostic and the location of the missing leaflet can be identified by computed tomography (CT). Emergent surgical correction is mandatory. We report a case of fractured escape of Edward-Duromedics mitral valve 27 years after the surgery. The patient presented with symptoms of acute decompensated heart failure and cardiogenic shock. She was instantly intubated and mechanically ventilated. After prompt evaluation including transthoracic echocardiography and CT, the escape of the leaflet was confirmed. The patient underwent emergent surgery for replacement of the damaged prosthetic valves immediately. Eleven days after the surgery, the dislodged leaflet in iliac artery was removed safely and the patient recovered well. PMID:23837121

  17. Advances in Retinal Prosthetic Research: A Systematic Review of Engineering and Clinical Characteristics of Current Prosthetic Initiatives.

    PubMed

    Cheng, Derrick L; Greenberg, Paul B; Borton, David A

    2017-03-01

    To date, reviews of retinal prostheses have focused primarily on devices undergoing human trials in the Western Hemisphere and fail to capture significant advances in materials and engineering research in countries such as Japan and Korea, as well as projects in early stages of development. To address these gaps, this systematic review examines worldwide advances in retinal prosthetic research, evaluates engineering characteristics and clinical progress of contemporary device initiatives, and identifies potential directions for future research in the field of retinal prosthetics. A literature search using PubMed, Google Scholar, and IEEExplore was conducted following the PRISMA Guidelines for Systematic Review. Inclusion criteria were peer-reviewed papers demonstrating progress in human or animal trials and papers discussing the prosthetic engineering design. For each initiative, a description of the device, its engineering considerations, and recent clinical results were provided. Ten prosthetic initiatives met our inclusion criteria and were organized by stimulation location. Of these initiatives, four have recently completed human trials, three are undergoing multi- or single-center human trials, and three are undergoing preclinical animal testing. Only the Argus II (FDA 2013, CE 2011) has obtained FDA approval for use in the United States; the Alpha-IMS (CE 2013) has achieved the highest visual acuity using a Landolt-C test to date and is the only device presently undergoing a multicenter clinical trial. Several distinct approaches to retinal stimulation have been successful in eliciting visual precepts in animals and/or humans. However, many clinical needs are still not met and engineering challenges must be addressed before a retinal prosthesis with the capability to fully and safely restore functional vision can be realized.

  18. [Intra-prosthetic dislocation of the Bousquet dual mobility socket].

    PubMed

    Lecuire, F; Benareau, I; Rubini, J; Basso, M

    2004-05-01

    The Bousquet system is a dual mobility head-polyethylene polyethylene-metal cup socket. The polyethylene insert retaining the femoral head moves in the noncemented metal cup, increasing both mobility and stability. Between 1989 and 1997, seven cases of intra-prosthetic dislocation (six patients) were observed. The femoral head escaped from the polyethylene insert due to wear. On the average, this complication occurred ten Years after implantation. Risk of dislocation was high in six of the seven hips. All patients had a large sized stem screwed into the femoral neck. There was a characteristic radiological aspect with loss of the concentric head metal cup configuration. The head was applied against the upper wall of the metal cup. Surgical replacement was undertaken early in six patients by simply changing the insert without modifying the other stable components. Outcome remained good at three to eight Years. One patient underwent late surgery. The insert and the cup were replaced with a classical implant. Functional outcome was good but recurrent dislocation occurred. At mid-term, intra-prosthetic dislocation of dual mobility sockets appears to be exceptional. Dislocation results from polyethylene wear leading to failure of the insert to retain the prosthetic head. Wear is favored by direct phenomena (direct contact between neck and insert which can occur early if there is a small difference in the head and neck diameters) or indirect phenomena (factors limiting polyethylene metal-cup mobility). Surgical treatment is necessary. If undertaken early, replacement with a modular head and insert can be sufficient if the prosthesis has not loosened but the metal cup may have to be replaced in the event of metal-metal contact between the head and the cup. Prosthesis loosening, wear of the metal cup, or an identified cause of dislocation imply replacing the failing implants. Implantation of the dual mobility system is particularly interesting for patients with a high risk

  19. [Influence of preoperative bone mass density in periprosthetic bone remodeling after implantation of ABG-II prosthesis: A 10-year follow-up].

    PubMed

    Aguilar Ezquerra, A; Panisello Sebastiá, J J; Mateo Agudo, J

    2016-01-01

    Preoperative bone mass index has shown to be an important factor in peri-prosthetic bone remodelling in short follow-up studies. Bone density scans (DXA) were used to perform a 10-year follow-up study of 39 patients with a unilateral, uncemented hip replacement. Bone mass index measurements were made at 6 months, one year, 3 years, 5 years, and 10 years after surgery. Pearson coefficient was used to quantify correlations between preoperative bone mass density (BMD) and peri-prosthetic BMD in the 7 Gruen zones at 6 months, one year, 3 years, 5 years, and 10 years. Pre-operative BMD was a good predictor of peri-prosthetic BMD one year after surgery in zones 1, 2, 4, 5 and 6 (Pearson index from 0.61 to 0.75). Three years after surgery it has good predictive power in zones 1, 4 and 5 (0.71-0.61), although in zones 3 and 7 low correlation was observed one year after surgery (0.51 and 0.57, respectively). At the end of the follow-up low correlation was observed in the 7 Gruen zones. Sex and BMI were found to not have a statistically significant influence on peri-prosthetic bone remodelling. Although preoperative BMD seems to be an important factor in peri-prosthetic remodelling one year after hip replacement, it loses its predictive power progressively, until not being a major factor in peri-prosthetic remodelling ten years after surgery. Copyright © 2015 SECOT. Published by Elsevier Espana. All rights reserved.

  20. Image segmentation for enhancing symbol recognition in prosthetic vision.

    PubMed

    Horne, Lachlan; Barnes, Nick; McCarthy, Chris; He, Xuming

    2012-01-01

    Current and near-term implantable prosthetic vision systems offer the potential to restore some visual function, but suffer from poor resolution and dynamic range of induced phosphenes. This can make it difficult for users of prosthetic vision systems to identify symbolic information (such as signs) except in controlled conditions. Using image segmentation techniques from computer vision, we show it is possible to improve the clarity of such symbolic information for users of prosthetic vision implants in uncontrolled conditions. We use image segmentation to automatically divide a natural image into regions, and using a fixation point controlled by the user, select a region to phosphenize. This technique improves the apparent contrast and clarity of symbolic information over traditional phosphenization approaches.

  1. Comparison between microprocessor-controlled ankle/foot and conventional prosthetic feet during stair negotiation in people with unilateral transtibial amputation.

    PubMed

    Agrawal, Vibhor; Gailey, Robert S; Gaunaurd, Ignacio A; O'Toole, Christopher; Finnieston, Adam A

    2013-01-01

    Contrary to stance-phase dorsiflexion of conventional prosthetic feet, the microprocessor-controlled Proprio foot permits swing-phase dorsiflexion on stairs. The purpose of this study was to compare Symmetry in External Work (SEW) between a microprocessor-controlled foot and conventional prosthetic feet in two groups with unilateral transtibial amputation (Medicare Functional Classification Levels K-Level-2 and K-Level-3) during stair ascent and descent. Ten subjects were evaluated while wearing three conventional prosthetic feet- solid ankle cushion heel (SACH), stationary attachment flexible endoskeleton (SAFE), and Talux-and the Proprio foot using a study socket and were given a 10- to 14-day accommodation period with each foot. Ground reaction forces were collected using F-scan sensors during stair ascent and descent. The SEW between the intact and amputated limbs was calculated for each foot. During stair ascent, the Proprio foot resulted in a higher interlimb symmetry than conventional prosthetic feet, with significant differences between the Pro prio and SACH/SAFE feet. The swing-phase dorsiflexion appeared to promote greater interlimb symmetry because it facilitated forward motion of the body, resulting in a heel-to-toe center of pressure trajectory. During stair descent, all feet had low symmetry without significant differences between feet. The movement strategy used when descending stairs, which is to roll over the edge of a step, had a greater influence on symmetry than the dorsiflexion features of prosthetic feet.

  2. Immediate two-stage prosthetic breast reconstruction failure: radiation is not the only culprit.

    PubMed

    Lam, Thomas C; Borotkanics, Robert; Hsieh, Frank; Salinas, James; Boyages, John

    2018-03-15

    Immediate prosthetic breast reconstruction produces a satisfactory aesthetic result with high levels of patient satisfaction. However, with the broader indication for post-mastectomy adjuvant radiation, many patients are advised against immediate breast reconstruction because of concerns of implant loss and infection particularly as most patients also require chemotherapy. This retrospective cohort study examines outcomes for patients who underwent immediate two-stage prosthetic breast reconstruction after mastectomy with or without adjuvant chemotherapy or radiotherapy (RT). Between 1998 and 2010, 452 patients undergoing two-stage prosthetic immediate breast reconstruction involving a total of 562 breasts were included in this study. Stage one was defined as insertion of the temporary expander and stage two insertion of the final silicone implant. Post-operative adjuvant radiotherapy was recommended with tissue expander in-situ for 114 patients. Complications, including loss of prosthesis, seroma and infection were recorded and analysed. Cosmetic result was assessed using a 4-point scale. Post-operative prosthesis loss was 2.7%, 5.3% for patients undergoing adjuvant chemotherapy increasing to 11.3% for patients receiving chemotherapy+RT. Chemotherapy and radiotherapy independently were the main, statistically significant, risk factors for expander or implant loss; IRR: 13.85 (p=0.012) and 2.23 (p=0.027), respectively. Prosthesis loss for patients undergoing combination chemotherapy+RT was also significant; IRR: 4.791 (p<0.001). These findings serve to better inform patients on risk in weighing treatment options. Post-mastectomy radiation doubles the risk of prosthesis loss over and above adjuvant chemotherapy but is an acceptable option following immediate prosthetic breast reconstruction in a multidisciplinary setting.

  3. Implant salvage in breast reconstruction with severe peri-prosthetic infection.

    PubMed

    Meybodi, Farid; Sedaghat, Negin; French, James; Keighley, Caitlin; Mitchell, David; Elder, Elisabeth

    2017-12-01

    Although treatment of mild peri-prosthetic infection in implant-based breast reconstruction results in high rates of resolution, successful management of severe peri-prosthetic infection remains a significant challenge. In this case series, a protocol utilizing a novel dressing - negative pressure wound therapy with instillation (NPWTi) - for the management of severe peri-prosthetic infection in breast reconstruction patients is described. This is an operative technique involving: (i) explantation of the breast prosthesis and application of the NPWTi dressing to the implant pocket; (ii) change of the NPWTi dressing; (iii) intraoperative fluid/tissue cultures; and (iv) reimplantation of the breast prosthesis when cultures yield no growth. This protocol was utilized in six cases of severe peri-prosthetic infection in five patients with immediate breast reconstruction for breast cancer or risk-reducing surgery. Cultures of fluid/tissue grew typical and/or unusual organisms. Only one case did not yield an organism. The hospital length of stay upon completion of the protocol ranged from 7-16 days (mean, 12 days). Successful implant salvage was achieved in five of six cases. The protocol was aborted in one case to allow for completion of adjuvant chemotherapy. Early findings from this case series suggest that in cases of severe peri-prosthetic infection this novel operative protocol may result in successful implant salvage for breast reconstruction patients. Further studies are needed to more fully elaborate the role of NPWTi to achieve implant salvage in challenging cases of peri-prosthetic infection. © 2015 Royal Australasian College of Surgeons.

  4. 24 DOF EMG controlled hybrid actuated prosthetic hand.

    PubMed

    Atasoy, A; Kaya, E; Toptas, E; Kuchimov, S; Kaplanoglu, E; Ozkan, M

    2016-08-01

    A complete mechanical design concept of an electromyogram (EMG) controlled hybrid prosthetic hand, with 24 degree of freedom (DOF) anthropomorphic structure is presented. Brushless DC motors along with Shape Memory Alloy (SMA) actuators are used to achieve dexterous functionality. An 8 channel EMG is used for detecting 7 basic hand gestures for control purposes. The prosthetic hand will be integrated with the Neural Network (NNE) based controller in the next phase of the study.

  5. Developing prescribing guidelines for microprocessor-controlled prosthetic knees in the South East England.

    PubMed

    Sedki, Imad; Fisher, Keren

    2015-06-01

    Microprocessor-controlled prosthetic knees have gained increasing popularity over the last decade. Research supports their provision to address specific problems or to achieve certain rehabilitation goals. However, there are yet no agreed protocols or prescribing criteria to assist clinicians in the identification and appropriate selection of suitable users. The aim is to reach professionals' agreement on specific prescribing guidelines for microprocessor-controlled prosthetic knees. The study involved multidisciplinary teams from the Inter Regional Prosthetic Audit Group, representing nine Prosthetic Rehabilitation Centres in the South East England region. We used the Delphi technique with a total of three rounds to reach professionals' agreement. The prescribing guidelines were agreed and will be reviewed and updated depending on new research evidence and technical advances. This project is highly useful for professionals in a clinic setting to aid in appropriate patient selection and to justify the cost of prescribing microprocessor-controlled prosthetic knees. © The International Society for Prosthetics and Orthotics 2014.

  6. Development of novel 3D-printed robotic prosthetic for transradial amputees.

    PubMed

    Gretsch, Kendall F; Lather, Henry D; Peddada, Kranti V; Deeken, Corey R; Wall, Lindley B; Goldfarb, Charles A

    2016-06-01

    Upper extremity myoelectric prostheses are expensive. The Robohand demonstrated that three-dimensional printing reduces the cost of a prosthetic extremity. The goal of this project was to develop a novel, inexpensive three-dimensional printed prosthesis to address limitations of the Robohand. The prosthesis was designed for patients with transradial limb amputation. It is shoulder-controlled and externally powered with an anthropomorphic terminal device. The user can open and close all five fingers, and move the thumb independently. The estimated cost is US$300. After testing on a patient with a traumatic transradial amputation, several advantages were noted. The independent thumb movement facilitated object grasp, the device weighed less than most externally powered prostheses, and the size was easily scalable. Limitations of the new prosthetic include low grip strength and decreased durability compared to passive prosthetics. Most children with a transradial congenital or traumatic amputation do not use a prosthetic. A three-dimensional printed shoulder-controlled robotic prosthesis provides a cost effective, easily sized and highly functional option which has been previously unavailable. © The International Society for Prosthetics and Orthotics 2015.

  7. Outdoor dynamic subject-specific evaluation of internal stresses in the residual limb: hydraulic energy-stored prosthetic foot compared to conventional energy-stored prosthetic feet.

    PubMed

    Portnoy, Sigal; Kristal, Anat; Gefen, Amit; Siev-Ner, Itzhak

    2012-01-01

    The prosthetic foot plays an important role in propelling, breaking, balancing and supporting body loads while the amputee ambulates on different grounds. It is therefore important to quantify the effect of the prosthetic foot mechanism on biomechanical parameters, in order to prevent pressure ulcers and deep tissue injury. Our aim was to monitor the internal stresses in the residuum of transtibial amputation (TTA) prosthetic-users ambulating on different terrains, which the amputees encounter during their daily activities, i.e. paved floor, grass, ascending and descending stairs and slope. We specifically aimed to compare between the internal stresses in the TTA residuum of amputees ambulating with a novel hydraulic prosthetic foot compared to conventional energy storage and return (ESR) prosthetic feet. Monitoring of internal stresses was accomplished using a portable subject-specific real-time internal stress monitor. We found significant decrease (p<0.01) in peak internal stresses and in the loading rate of the amputated limb, while walking with the hydraulic foot, compared to walking with ESR feet. The loading rate calculated while ambulating with the hydraulic foot was at least three times lower than the loading rate calculated while ambulating with the ESR foot. Although the average decrease in internal stresses was ≈ 2-fold larger when replacing single-toe ESR feet with the hydraulic foot than when replacing split-toed ESR feet with the hydraulic foot, the differences were statistically insignificant. Our findings suggest that using a hydraulic prosthetic foot may protect the distal tibial end of the TTA residuum from high stresses, therefore preventing pressure-related injury and pain. Copyright © 2011 Elsevier B.V. All rights reserved.

  8. Retinal Prosthetics, Optogenetics, and Chemical Photoswitches

    PubMed Central

    2015-01-01

    Three technologies have emerged as therapies to restore light sensing to profoundly blind patients suffering from late-stage retinal degenerations: (1) retinal prosthetics, (2) optogenetics, and (3) chemical photoswitches. Prosthetics are the most mature and the only approach in clinical practice. Prosthetic implants require complex surgical intervention and provide only limited visual resolution but can potentially restore navigational ability to many blind patients. Optogenetics uses viral delivery of type 1 opsin genes from prokaryotes or eukaryote algae to restore light responses in survivor neurons. Targeting and expression remain major problems, but are potentially soluble. Importantly, optogenetics could provide the ultimate in high-resolution vision due to the long persistence of gene expression achieved in animal models. Nevertheless, optogenetics remains challenging to implement in human eyes with large volumes, complex disease progression, and physical barriers to viral penetration. Now, a new generation of photochromic ligands or chemical photoswitches (azobenzene-quaternary ammonium derivatives) can be injected into a degenerated mouse eye and, in minutes to hours, activate light responses in neurons. These photoswitches offer the potential for rapidly and reversibly screening the vision restoration expected in an individual patient. Chemical photoswitch variants that persist in the cell membrane could make them a simple therapy of choice, with resolution and sensitivity equivalent to optogenetics approaches. A major complexity in treating retinal degenerations is retinal remodeling: pathologic network rewiring, molecular reprogramming, and cell death that compromise signaling in the surviving retina. Remodeling forces a choice between upstream and downstream targeting, each engaging different benefits and defects. Prosthetics and optogenetics can be implemented in either mode, but the use of chemical photoswitches is currently limited to downstream

  9. Current antibiotic management of prosthetic joint infections in Italy: the 'Udine strategy'.

    PubMed

    Bassetti, Matteo; Cadeo, Barbara; Villa, Giovanni; Sartor, Assunta; Cainero, Vanni; Causero, Araldo

    2014-09-01

    The rate of prosthetic joint infections followed and cured at our institution is constantly increasing, in line with epidemiological data from the recent literature. This is probably related to the greater number of knee and hip prostheses implanted every year. For intermediate and late infections, only the two-stage approach is applied, as this demonstrates the best outcome in our experience. Particular attention is paid to microbiological isolation of the pathogen: multiple samples of tissue are collected during the interventions, and kept in culture for a longer period of time than usual. Sonication of prosthetic devices is used to enhance the sensitivity and specificity of the microbiological cultures. Histological examination influences surgical choices either towards implantation of a new prosthesis or replacement of the spacer. An empirical antibiotic backbone of a glycopeptide/lipopeptide and rifampicin is chosen, due to the leading role of Gram-positive bacteria in this setting and the high incidence of methicillin resistance in our centre (>30%), followed by an antibiotic regimen containing linezolid. If specific risk factors are present, an anti-Gram-negative drug is added to the regimen. Duration of therapy depends upon the approach that is chosen, usually being 6 weeks when the prosthesis is removed. Despite at the moment being limited by its small sample size, data from our experience confirms that our empirical approach may represent a valid choice during the early phase of treatment, by keeping linezolid for a step-down therapy of shorter duration (4 weeks). © The Author 2014. Published by Oxford University Press on behalf of the British Society for Antimicrobial Chemotherapy. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  10. Effects of a flat prosthetic foot rocker section on balance and mobility.

    PubMed

    Hansen, Andrew; Nickel, Eric; Medvec, Joseph; Brielmaier, Steven; Pike, Alvin; Weber, Marilyn

    2014-01-01

    Previous studies have shown that the effective rocker shape of the physiologic ankle-foot system during standing and fore-aft swaying is much flatter than that used during walking, which indicates a more stable base of support for the standing/swaying activity. Previous work suggests that flat regions within the effective rocker shapes of prosthetic ankle-foot systems could provide enhanced stability for standing balance tasks. An experimental prosthetic foot was altered to provide three different flat region lengths within its effective rocker shape. It was hypothesized that longer flat regions of the effective rocker shape would lead to improved standing balance outcomes and reduced walking performance for unilateral transtibial prosthesis users. However, no significant changes were seen in the balance and mobility outcomes of 12 unilateral transtibial prosthesis users when using the three prosthetic foot conditions. Subjects in the study significantly preferred prosthetic feet with relatively low to moderate flat regions over those with long flat regions. All the subjects without loss of light touch or vibratory sensation selected the prosthetic foot with the shortest flat region. More work is needed to investigate the effects of prosthetic foot properties on balance and mobility of prosthesis users.

  11. Structural Integration and Control of Peerless Human-like Prosthetic Hand

    NASA Astrophysics Data System (ADS)

    Dave, Ankit; Muthu, P.; Karthikraj, V.; Latha, S.

    2018-04-01

    Limb damage can create severe disturbance in movement and operative abilities wherein the prosthetic rehabilitation has the potential to replace function and enhance the quality of life. This paper presents a humanlike prosthetic hand using such unique design concept of hand model using artificial bones, ligaments, and tendons controlled using Arduino. Amongst various platforms available, Arduino is known for its adaptability, adoration and low cost. The design of prosthetic hand has a unique structure with all carpal, metacarpal, and phalanges which are bones of the hand. These bones are attached to each other following the pattern of human hand using the polymeric rubber as a functioning ligament. Furthermore, this structure of finger is driven by tendons attached to all fingers and passes through the ligaments working as pulley resulting in more degrees of freedom. The motor can twitch the tendons to achieve the action of fingers. Thus the servos, controlled by an Arduino, are used to regulate the movement mechanism of the prosthetic hand.

  12. Fungal prosthetic valve endocarditis with mycotic aneurysm: Case report.

    PubMed

    Brandão, Mariana; Almeida, Jorge; Ferraz, Rita; Santos, Lurdes; Pinho, Paulo; Casanova, Jorge

    2016-09-01

    Fungal prosthetic valve endocarditis is an extremely severe form of infective endocarditis, with poor prognosis and high mortality despite treatment. Candida albicans is the most common etiological agent for this rare but increasingly frequent condition. We present a case of fungal prosthetic valve endocarditis due to C. albicans following aortic and pulmonary valve replacement in a 38-year-old woman with a history of surgically corrected tetralogy of Fallot, prior infective endocarditis and acute renal failure with need for catheter-based hemodialysis. Antifungal therapy with liposomal amphotericin B was initiated prior to cardiac surgery, in which the bioprostheses were replaced by homografts, providing greater resistance to recurrent infection. During hospitalization, a mycotic aneurysm was diagnosed following an episode of acute arterial ischemia, requiring two vascular surgical interventions. Despite the complications, the patient's outcome was good and she was discharged on suppressive antifungal therapy with oral fluconazole for at least a year. The reported case illustrates multiple risk factors for fungal endocarditis, as well as complications and predictors of poor prognosis, demonstrating its complexity. Copyright © 2016 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  13. The Effects of the Inertial Properties of Above-Knee Prostheses on Optimal Stiffness, Damping, and Engagement Parameters of Passive Prosthetic Knees.

    PubMed

    Narang, Yashraj S; Murthy Arelekatti, V N; Winter, Amos G

    2016-12-01

    Our research aims to design low-cost, high-performance, passive prosthetic knees for developing countries. In this study, we determine optimal stiffness, damping, and engagement parameters for a low-cost, passive prosthetic knee that consists of simple mechanical elements and may enable users to walk with the normative kinematics of able-bodied humans. Knee joint power was analyzed to divide gait into energy-based phases and select mechanical components for each phase. The behavior of each component was described with a polynomial function, and the coefficients and polynomial order of each function were optimized to reproduce the knee moments required for normative kinematics of able-bodied humans. Sensitivity of coefficients to prosthesis mass was also investigated. The knee moments required for prosthesis users to walk with able-bodied normative kinematics were accurately reproduced with a mechanical system consisting of a linear spring, two constant-friction dampers, and three clutches (R2=0.90 for a typical prosthetic leg). Alterations in upper leg, lower leg, and foot mass had a large influence on optimal coefficients, changing damping coefficients by up to 180%. Critical results are reported through parametric illustrations that can be used by designers of prostheses to select optimal components for a prosthetic knee based on the inertial properties of the amputee and his or her prosthetic leg.

  14. Control system and method for prosthetic devices

    NASA Technical Reports Server (NTRS)

    Bozeman, Richard J., Jr. (Inventor)

    1992-01-01

    A control system and method for prosthetic devices is provided. The control system comprises a transducer for receiving movement from a body part for generating a sensing signal associated with that movement. The sensing signal is processed by a linearizer for linearizing the sensing signal to be a linear function of the magnitude of the distance moved by the body part. The linearized sensing signal is normalized to be a function of the entire range of body part movement from the no-shrug position of the movable body part through the full-shrug position of the movable body part. The normalized signal is divided into a plurality of discrete command signals. The discrete command signals are used by typical converter devices which are in operational association with the prosthetic device. The converter device uses the discrete command signals for driving the movable portions of the prosthetic device and its sub-prosthesis. The method for controlling a prosthetic device associated with the present invention comprises the steps of receiving the movement from the body part, generating a sensing signal in association with the movement of the body part, linearizing the sensing signal to be a linear function of the magnitude of the distance moved by the body part, normalizing the linear signal to be a function of the entire range of the body part movement, dividing the normalized signal into a plurality of discrete command signals, and implementing the plurality of discrete command signals for driving the respective movable prosthesis device and its sub-prosthesis.

  15. Prosthetic Hand Lifts Heavy Loads

    NASA Technical Reports Server (NTRS)

    Carden, James R.; Norton, William; Belcher, Jewell G.; Vest, Thomas W.

    1991-01-01

    Prosthetic hand designed to enable amputee to lift diverse heavy objects like rocks and logs. Has simple serrated end effector with no moving parts. Prosthesis held on forearm by system of flexible straps. Features include ruggedness, simplicity, and relatively low cost.

  16. User surveys support designing a prosthetic wrist that incorporates the Dart Thrower's Motion.

    PubMed

    Davidson, Matthew; Bodine, Cathy; Weir, Richard F Ff

    2018-03-07

    Prosthetic devices are not meeting the needs of people with upper limb amputations. Due to controlsidelimitations, prosthetic wrists cannot yet be fully articulated. This study sought to determine which wrist motions users felt were most important for completing activities of daily living. We specifically invstigated whether adding a combinationof flexion and deviation known as the Dart Thrower's Motion to a prosthetic wrist would help improve functionality. Fifteen participants with a trans-radial amputation, aged 25-64 years, who use a prosthesis completed an online survey and answered interview questions to determine which types of tasks pose particular challenges. Participants were asked what kinds of improvements they would like to see in a new prosthesis. A subset of five participants were interviewed in-depth to provide further information about difficulties they face using their device. The survey showed that participants had difficulty performing activities of daily living that involve a combination of wrist flexion and deviation known as the "Dart Throwers Motion". Interview responses confirmed that users have difficulty performing these tasks, especially those that require tools. Additionally, users said that they were more interested in having flexion and deviation than rotation in a prosthetic wrist. This research indicates that including the Dart Thrower's Motion in future designs of prosthetic wrists would improve these devices and people with upper limb amputations would be excited to see this improvement in their devices. Implications for Rehabilitation • Over one third of people with upper limb amputations do not use a prosthesis because prosthetic devices do not meet their needs.• The number of motions possible in state of the art prosthetic devices is limited by the small number of control sites available.• The Dart Thrower?s Motion is a wrist motion used for many activities of daily living but unavailable in commercial prosthetics

  17. Surgical and Antimicrobial Treatment of Prosthetic Vascular Graft Infections at Different Surgical Sites: A Retrospective Study of Treatment Outcomes

    PubMed Central

    Elzi, Luigia; Gurke, Lorenz; Battegay, Manuel; Widmer, Andreas F.; Weisser, Maja

    2014-01-01

    Objective Little is known about optimal management of prosthetic vascular graft infections, which are a rare but serious complication associated with graft implants. The goal of this study was to compare and characterize these infections with respect to the location of the graft and to identify factors associated with outcome. Methods This was a retrospective study over more than a decade at a tertiary care university hospital that has an established multidisciplinary approach to treating graft infections. Cases of possible prosthetic vascular graft infection were identified from the hospital's infectious diseases database and evaluated against strict diagnostic criteria. Patients were divided into groups according to the locations of their grafts: thoracic-aortic, abdominal-aortic, or peripheral-arterial. Statistical analyses included evaluation of patient and infection characteristics, time to treatment failure, and factors associated specifically with cure rates in aortic graft infections. The primary endpoint was cure at one year after diagnosis of the infection. Results Characterization of graft infections according to the graft location did show that these infections differ in terms of their characteristics and that the prognosis for treatment seems to be influenced by the location of the infection. Cure rate and all-cause mortality at one year were 87.5% and 12.5% in 24 patients with thoracic-aortic graft infections, 37.0% and 55.6% in 27 patients with abdominal-aortic graft infections, and 70.0% and 30.0% in 10 patients with peripheral-arterial graft infections. In uni- and multivariate analysis, the type of surgical intervention used in managing infections (graft retention versus graft replacement) did not affect primary outcome, whereas a rifampicin-based antimicrobial regimen was associated with a higher cure rate. Conclusions We recommend that future prospective studies differentiate prosthetic vascular graft infections according to the location of the

  18. Multi-Axis Prosthetic Knee Resembles Alpine Skiing Movements of an Intact Leg

    PubMed Central

    Demšar, Ivan; Duhovnik, Jože; Lešnik, Blaž; Supej, Matej

    2015-01-01

    The purpose of the study was to analyse the flexion angles of the ski boot, ankle and knee joints of an above-knee prosthesis and to compare them with an intact leg and a control group of skiers. One subject with an above-knee amputation of the right leg and eight healthy subjects simulated the movement of a skiing turn by performing two-leg squats in laboratory conditions. By adding additional loads in proportion to body weight (BW; +1/3 BW, +2/3 BW, +3/3 BW), various skiing regimes were simulated. Change of Flexion Angle (CoFA) and Range of Motion (RoM) in the ski boot, ankle and knee joints were calculated and compared. An average RoM in the skiing boot on the side of prosthesis (4.4 ± 1.1°) was significantly lower compared to an intact leg (5.9 ± 1.8°) and the control group (6.5 ± 2.3°). In the ankle joint, the average RoM was determined to be 13.2±2.9° in the prosthesis, 12.7 ± 2.8° in an intact leg and 14.8±3.6 in the control group. However, the RoM of the knee joint in the prosthesis (42.2 ± 4.2°) was significantly larger than that of the intact leg (34.7 ± 4.4°). The average RoM of the knee joint in the control group was 47.8 ± 5.4°. The influences of additional loads on the kinematics of the lower extremities were different on the side of the prosthesis and on the intact leg. In contrast, additional loads did not produce any significant differences in the control group. Although different CoFAs in the ski boot, ankle and knee joints were used, an above-knee prosthesis with a built-in multi-axis prosthetic knee enables comparable leg kinematics in simulated alpine skiing. Key points The RoM in the ski boot on the side of the prosthetic leg was smaller than the RoM of the intact leg and the control group of healthy subjects. The RoM in the ankle joint of prosthetic leg was comparable to that of the intact leg and the control group of healthy subjects. The RoM in the prosthetic knee joint was greater than the RoM in the knee joint of the

  19. Gonococcal Prosthetic Joint Infection.

    PubMed

    Gassiep, Ian; Gilpin, Bradley; Douglas, Joel; Siebert, David

    2017-01-01

    Neisseria gonorrhoea is a common sexually transmitted infection worldwide. Disseminated gonococcal infection is an infrequent presentation and rarely can be associated with septic arthritis. Incidence of this infection is rising, both internationally and in older age groups. We present the first documented case of N. gonorrhoea prosthetic joint infection which was successfully treated with laparoscopic debridement and antimicrobial therapy.

  20. Rotational joint for prosthetic leg

    NASA Technical Reports Server (NTRS)

    Jones, W. C.; Owens, L. J.

    1977-01-01

    Device is installed in standard 30 millimeter tubing used for lower leg prosthetics. Unit allows proper rotation (about 3 degrees) of foot relative to the hip, during normal walking or running. Limited rotational movement with restoring force results in a more natural gait.

  1. Rehand: Realistic electric prosthetic hand created with a 3D printer.

    PubMed

    Yoshikawa, Masahiro; Sato, Ryo; Higashihara, Takanori; Ogasawara, Tsukasa; Kawashima, Noritaka

    2015-01-01

    Myoelectric prosthetic hands provide an appearance with five fingers and a grasping function to forearm amputees. However, they have problems in weight, appearance, and cost. This paper reports on the Rehand, a realistic electric prosthetic hand created with a 3D printer. It provides a realistic appearance that is same as the cosmetic prosthetic hand and a grasping function. A simple link mechanism with one linear actuator for grasping and 3D printed parts achieve low cost, light weight, and ease of maintenance. An operating system based on a distance sensor provides a natural operability equivalent to the myoelectric control system. A supporter socket allows them to wear the prosthetic hand easily. An evaluation using the Southampton Hand Assessment Procedure (SHAP) demonstrated that an amputee was able to operate various objects and do everyday activities with the Rehand.

  2. Interactions of Prosthetic and Natural Vision in Animals With Local Retinal Degeneration

    PubMed Central

    Lorach, Henri; Lei, Xin; Galambos, Ludwig; Kamins, Theodore; Mathieson, Keith; Dalal, Roopa; Huie, Philip; Harris, James; Palanker, Daniel

    2015-01-01

    Purpose Prosthetic restoration of partial sensory loss leads to interactions between artificial and natural inputs. Ideally, the rehabilitation should allow perceptual fusion of the two modalities. Here we studied the interactions between normal and prosthetic vision in a rodent model of local retinal degeneration. Methods Implantation of a photovoltaic array in the subretinal space of normally sighted rats induced local degeneration of the photoreceptors above the chip, and the inner retinal neurons in this area were electrically stimulated by the photovoltaic implant powered by near-infrared (NIR) light. We studied prosthetic and natural visually evoked potentials (VEP) in response to simultaneous stimulation by NIR and visible light patterns. Results We demonstrate that electrical and natural VEPs summed linearly in the visual cortex, and both responses decreased under brighter ambient light. Responses to visible light flashes increased over 3 orders of magnitude of contrast (flash/background), while for electrical stimulation the contrast range was limited to 1 order of magnitude. The maximum amplitude of the prosthetic VEP was three times lower than the maximum response to a visible flash over the same area on the retina. Conclusions Ambient light affects prosthetic responses, albeit much less than responses to visible stimuli. Prosthetic representation of contrast in the visual scene can be encoded, to a limited extent, by the appropriately calibrated stimulus intensity, which also depends on the ambient light conditions. Such calibration will be important for patients combining central prosthetic vision with natural peripheral sight, such as in age-related macular degeneration. PMID:26618643

  3. 77 FR 14989 - Medicare Program; Revisions to the Durable Medical Equipment, Prosthetics, Orthotics, and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-14

    ... wheelchairs. Prosthetic devices are included in the definition of ``medical and other health services'' in section 1861(s)(8) of the Act. Prosthetic devices are defined as devices (other than dental) which replace... examples of prosthetic devices include cardiac pacemakers, cochlear implants, electrical continence aids...

  4. Novel Materials for Prosthetic Liners

    NASA Technical Reports Server (NTRS)

    Ragolta, Carolina I.; Morford, Megan

    2011-01-01

    Existing materials for prosthetic liners tend to be thick and airtight, causing perspiration to accumulate inside the liner and potentially causing infection and injury that reduce quality of life. The purpose of this project was to examine the suitability of aerogel for prosthetic liner applications. Three tests were performed on several types of aerogel to assess the properties of each material. Moisture vapor permeability was tested by incubating four aerogel varieties with an artificial sweat solution at 37.0 C and less than 20% relative humidity for 24 hours. Two aerogel varieties were eliminated from the study due to difficulties in handling the material, and further testing proceeded with Pyrogel in 2.0 and 6.0 mm thicknesses. Force distribution was tested by compressing samples under a load of 4448 N at a rate of 2.5 mm/min. Biofilm formation was tested in a high-shear CDC Biofilm Reactor. Results showed that 2.0 mm Pyrogel blanket allowed 55.7 plus or minus 28.7% of an artificial sweat solution to transpire, and 35.5 plus or minus 27.8% transpired through 6.0 mm Pyrogel blanket. Samples also outperformed the load-bearing capabilities of existing liner materials. No statistically significant difference was found between the two Pyrogel thicknesses for either moisture vapor permeability or force distribution. In addition, biofilm formation results showed no change between the two Pyrogel thicknesses. The breathability and load bearing properties of aerogel make it a suitable material for application to prosthetic liners.

  5. A computational method for comparing the behavior and possible failure of prosthetic implants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nielsen, C.; Hollerbach, K.; Perfect, S.

    1995-05-01

    Prosthetic joint implants currently in use exhibit high Realistic computer modeling of prosthetic implants provides an opportunity for orthopedic biomechanics researchers and physicians to understand possible in vivo failure modes, without having to resort to lengthy and costly clinical trials. The research presented here is part of a larger effort to develop realistic models of implanted joint prostheses. The example used here is the thumb carpo-metacarpal (cmc) joint. The work, however, can be applied to any other human joints for which prosthetic implants have been designed. Preliminary results of prosthetic joint loading, without surrounding human tissue (i.e., simulating conditions undermore » which the prosthetic joint has not yet been implanted into the human joint), are presented, based on a three-dimensional, nonlinear finite element analysis of three different joint implant designs.« less

  6. Modeling of Prosthetic Limb Rotation Control by Sensing Rotation of Residual Arm Bone

    PubMed Central

    Kuiken, Todd A.

    2011-01-01

    We proposed a new approach to improve the control of prosthetic arm rotation in amputees. Arm rotation is sensed by implanting a small permanent magnet into the distal end of the residual bone, which produces a magnetic field. The position of the bone rotation can be derived from magnetic field distribution detected with magnetic sensors on the arm surface, and then conveyed to the prosthesis controller to manipulate the rotation of the prosthesis. Proprioception remains intact for residual limb skeletal structures; thus, this control system should be natural and easy-to-use. In this study, simulations have been conducted in an upper arm model to assess the feasibility and performance of sensing the voluntary rotation of residual humerus with an implanted magnet. A sensitivity analysis of the magnet size and arm size was presented. The influence of relative position of the magnet to the magnetic sensors, orientation of the magnet relative to the limb axis, and displacement of the magnetic sensors on the magnetic field was evaluated. The performance of shielding external magnetostatic interference was also investigated. The simulation results suggest that the direction and angle of rotation of residual humerus could be obtained by decoding the magnetic field signals with magnetic sensors built into a prosthetic socket. This pilot study provides important guidelines for developing a practical interface between the residual bone rotation and the prosthesis for control of prosthetic rotation. PMID:18713682

  7. The effects of prosthetic foot roll-over shape arc length on the gait of trans-tibial prosthesis users.

    PubMed

    Hansen, Andrew H; Meier, Margrit R; Sessoms, Pinata H; Childress, Dudley S

    2006-12-01

    The Shape&Roll prosthetic foot was used to examine the effect of roll-over shape arc length on the gait of 14 unilateral trans-tibial prosthesis users. Simple modifications to the prosthetic foot were used to alter the effective forefoot rocker length, leaving factors such as alignment, limb length, and heel and mid-foot characteristics unchanged. Shortening the roll-over shape arc length caused a significant reduction in the maximum external dorsiflexion moment on the prosthetic side at all walking speeds (p < 0.001 for main effect of arc length), due to a reduction in forefoot leverage (moment arm) about the ankle. Roll-over shape arc length significantly affected the initial loading on the sound limb at normal and fast speeds (p = 0.001 for the main effect of arc length), with participants experiencing larger first peaks of vertical ground reaction forces on their sound limbs when using the foot with the shortest effective forefoot rocker arc length. Additionally, the difference between step lengths on the sound and prosthetic limbs was larger with the shortest arc length condition, although this difference was not statistically significant (p = 0.06 for main effect). It appears that prosthesis users may experience a drop-off effect at the end of single limb stance on prosthetic feet with short roll-over shape arc lengths, leading to increased loading and/or a shortened step on the contralateral limb.

  8. 76 FR 18472 - Medicare Program; Revisions to the Durable Medical Equipment, Prosthetics, Orthotics, and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-04

    ....Prosthetic devices are included in the definition of ``medical and other health services'' under section 1861(s)(8) of the Act. Prosthetic devices are defined in this section of the Act as ``devices (other than... intraocular lens.'' Other examples of prosthetic devices include cardiac pacemakers, cochlear implants...

  9. Design and Evaluation of a Prosthetic Knee Joint Using the Geared Five-Bar Mechanism.

    PubMed

    Sun, Yuanxi; Ge, Wenjie; Zheng, Jia; Dong, Dianbiao

    2015-11-01

    This paper presents the mechanical design, dynamics analysis and ankle trajectory analysis of a prosthetic knee joint using the geared five-bar mechanism. Compared with traditional four-bar or six-bar mechanisms, the geared five-bar mechanism is better at performing diverse movements and is easy to control. This prosthetic knee joint with the geared five-bar mechanism is capable of fine-tuning its relative instantaneous center of rotation and ankle trajectory. The centrode of this prosthetic knee joint, which is mechanically optimized according to the centrode of human knee joint, is better in the bionic performance than that of a prosthetic knee joint using the four-bar mechanism. Additionally, the stability control of this prosthetic knee joint during the swing and stance phase is achieved by a motor. By adjusting the gear ratio of this prosthetic knee joint, the ankle trajectories of both unilateral and bilateral amputees show less deviations from expected than that of the four-bar knee joint.

  10. Pinch-force-magnification mechanism of low degree of freedom EMG prosthetic hand for children.

    PubMed

    Ye, Hesong; Sakoda, Shintaro; Jiang, Yinlai; Morishita, Soichiro; Yokoi, Hiroshi

    2015-01-01

    EMG prosthetic hands are being extensively studied for the disabled who need them not only for cosmesis but also for the functions to help them with basic daily activities. However, most EMG prosthetic hands are developed for adults. Since the early use of prosthetic hands is important for the children to accept and adapt to them, we are developing low degrees of freedom (DoF) prosthetic hand that is suitable for children. Due to the limited size of a child's hand, the servo motor which drives the MP joint are small-sized and low-power. Hence, a pinch-force-magnification mechanism is required to improve the pinch force of the EMG prosthetic hand. In this paper we designed a wire-driven mechanism which can magnify pinch force by increasing the length of the MP joint's moment arm. Pinch force measurement experiment validated that the pinch force of the prosthetic hand with the mechanism is more than twice of that of the hand with direct drive.

  11. A mechatronics platform to study prosthetic hand control using EMG signals.

    PubMed

    Geethanjali, P

    2016-09-01

    In this paper, a low-cost mechatronics platform for the design and development of robotic hands as well as a surface electromyogram (EMG) pattern recognition system is proposed. This paper also explores various EMG classification techniques using a low-cost electronics system in prosthetic hand applications. The proposed platform involves the development of a four channel EMG signal acquisition system; pattern recognition of acquired EMG signals; and development of a digital controller for a robotic hand. Four-channel surface EMG signals, acquired from ten healthy subjects for six different movements of the hand, were used to analyse pattern recognition in prosthetic hand control. Various time domain features were extracted and grouped into five ensembles to compare the influence of features in feature-selective classifiers (SLR) with widely considered non-feature-selective classifiers, such as neural networks (NN), linear discriminant analysis (LDA) and support vector machines (SVM) applied with different kernels. The results divulged that the average classification accuracy of the SVM, with a linear kernel function, outperforms other classifiers with feature ensembles, Hudgin's feature set and auto regression (AR) coefficients. However, the slight improvement in classification accuracy of SVM incurs more processing time and memory space in the low-level controller. The Kruskal-Wallis (KW) test also shows that there is no significant difference in the classification performance of SLR with Hudgin's feature set to that of SVM with Hudgin's features along with AR coefficients. In addition, the KW test shows that SLR was found to be better in respect to computation time and memory space, which is vital in a low-level controller. Similar to SVM, with a linear kernel function, other non-feature selective LDA and NN classifiers also show a slight improvement in performance using twice the features but with the drawback of increased memory space requirement and time

  12. Evolution of penile prosthetic devices

    PubMed Central

    Burnett, Arthur L.

    2015-01-01

    Penile implant usage dates to the 16th century yet penile implants to treat erectile dysfunction did not occur until nearly four centuries later. The modern era of penile implants has progressed rapidly over the past 50 years as physicians' knowledge of effective materials for penile prostheses and surgical techniques has improved. Herein, we describe the history of penile prosthetics and the constant quest to improve the technology. Elements of the design from the first inflatable penile prosthesis by Scott and colleagues and the Small-Carrion malleable penile prosthesis are still found in present iterations of these devices. While there have been significant improvements in penile prosthesis design, the promise of an ideal prosthetic device remains elusive. As other erectile dysfunction therapies emerge, penile prostheses will have to continue to demonstrate a competitive advantage. A particular strength of penile prostheses is their efficacy regardless of etiology, thus allowing treatment of even the most refractory cases. PMID:25763121

  13. Evolution of penile prosthetic devices.

    PubMed

    Le, Brian; Burnett, Arthur L

    2015-03-01

    Penile implant usage dates to the 16th century yet penile implants to treat erectile dysfunction did not occur until nearly four centuries later. The modern era of penile implants has progressed rapidly over the past 50 years as physicians' knowledge of effective materials for penile prostheses and surgical techniques has improved. Herein, we describe the history of penile prosthetics and the constant quest to improve the technology. Elements of the design from the first inflatable penile prosthesis by Scott and colleagues and the Small-Carrion malleable penile prosthesis are still found in present iterations of these devices. While there have been significant improvements in penile prosthesis design, the promise of an ideal prosthetic device remains elusive. As other erectile dysfunction therapies emerge, penile prostheses will have to continue to demonstrate a competitive advantage. A particular strength of penile prostheses is their efficacy regardless of etiology, thus allowing treatment of even the most refractory cases.

  14. Cochlear Implant Using Neural Prosthetics

    NASA Astrophysics Data System (ADS)

    Gupta, Shweta; Singh, Shashi kumar; Dubey, Pratik Kumar

    2012-10-01

    This research is based on neural prosthetic device. The oldest and most widely used of these electrical, and often computerized, devices is the cochlear implant, which has provided hearing to thousands of congenitally deaf people in this country. Recently, the use of the cochlear implant is expanding to the elderly, who frequently suffer major hearing loss. More cutting edge are artificial retinas, which are helping dozens of blind people see, and ìsmartî artificial arms and legs that amputees can maneuver by thoughts alone, and that feel more like real limbs.Research, which curiosity led to explore frog legs dancing during thunderstorms, a snail shapedorgan in the inner ear, and how various eye cells react to light, have fostered an understanding of how to ìtalkî to the nervous system. That understanding combined with the miniaturization of electronics and enhanced computer processing has enabled prosthetic devices that often can bridge the gap in nerve signaling that is caused by disease or injury.

  15. [Tuberculous prosthetic knee joint infection: a case report and literature review].

    PubMed

    Lara-Oya, A; Liébana-Martos, M C; Rodríguez-Granger, J; Sampedro-Martínez, A; Aliaga-Martínez, L; Gutierrez-Fernández, J; Navarro-Marí, J M

    2016-08-01

    Prosthetic late infection occurs in the second month after surgery in the context of haematogenous spread from another source. Prosthetic mycobacterial infection is a rare complication whose clinical management is not standardized. Patient of 77 years with no personal history except for diabetes and a prosthetic replacement of right knee with osteoarthritis three years ago. Patient goes to hospital emergency box for 6 months pain in the right knee with mechanical inflammatory signs but no fever associated. After their return within 5 days and clinical worsening is reporting growth of Mycobacterium tuberculosis in knee aspirate and antitubercular treatment is established for 9 months. Nuclear magnetic resonance imaging studies also confirmed the diagnosis of tuberculosis spondylitis in the clinical context of the patients. After surgery, M. tuberculosis was again isolated from intraoperative samples and therefore the patient received another batch of treatment for 9 months. After a year of monitoring, the development was acceptable but few months later, the patient died for cardiovascular causes. In the literature review, 15 publications with a total of 17 clinical cases of prosthetic infection by M. tuberculosis were found from 1980 to 2014. Prosthetic tuberculous arthritis, although it is a rare presentation, it should be noted, especially in patients with predisposing conditions with a history of tuberculosis infection.

  16. Control of a powered prosthetic device via a pinch gesture interface

    NASA Astrophysics Data System (ADS)

    Yetkin, Oguz; Wallace, Kristi; Sanford, Joseph D.; Popa, Dan O.

    2015-06-01

    A novel system is presented to control a powered prosthetic device using a gesture tracking system worn on a user's sound hand in order to detect different grasp patterns. Experiments are presented with two different gesture tracking systems: one comprised of Conductive Thimbles worn on each finger (Conductive Thimble system), and another comprised of a glove which leaves the fingers free (Conductive Glove system). Timing tests were performed on the selection and execution of two grasp patterns using the Conductive Thimble system and the iPhone app provided by the manufacturer. A modified Box and Blocks test was performed using Conductive Glove system and the iPhone app provided by Touch Bionics. The best prosthetic device performance is reported with the developed Conductive Glove system in this test. Results show that these low encumbrance gesture-based wearable systems for selecting grasp patterns may provide a viable alternative to EMG and other prosthetic control modalities, especially for new prosthetic users who are not trained in using EMG signals.

  17. Prosthetic design directives: Low-cost hands within reach.

    PubMed

    Jones, G K; Rosendo, A; Stopforth, R

    2017-07-01

    Although three million people around the world suffer from the lack of one or both upper limbs 80% of this number is located within developing countries. While prosthetic prices soar with technology 3D printing and low cost electronics present a sensible solution for those that cannot afford expensive prosthetics. The electronic and control design of a low-cost prosthetic hand, the Touch Hand II, is discussed. This paper shows that sensorless techniques can be used to reduce design complexities, costs, and provide easier access to the electronics. A closing and opening finite state machine (COFSM) was developed to handle the actuated digit joint control state and a supervisory switching control scheme, used for speed and grip strength control. Three torque and speed settings were created to be preset for specific grasps. The hand was able to replicate ten frequently used grasps and grip some common objects. Future work is necessary to enable a user to control it with myoelectric signals (MESs) and to solve operational problems related to electromagnetic interference (EMI).

  18. Impact of depressive symptoms on prosthetic status--results of the study of health in Pomerania (SHIP).

    PubMed

    Samietz, Stefanie A; Kindler, Stefan; Schwahn, Christian; Polzer, Ines; Hoffmann, Wolfgang; Kocher, Thomas; Grabe, Hans Jörgen; Mundt, Torsten; Biffar, Reiner

    2013-05-01

    Previous investigations have confirmed that every fifth dental patient suffers from clinically significant depressive symptoms. However, the putative impact of depressive symptoms on the prosthetic status has not been addressed in these studies. The objective of this study was to investigate the association between depressive symptoms and prosthetic status based on data from the Study of Health in Pomerania (SHIP-0). Data from 2,135 participants aged 30 to 59 years were analyzed. A classification (six classes regarding the number and position of missing teeth per jaw) was used to identify the degree of prosthetic status (no/suboptimal/optimal tooth replacement). The presence of depressive symptoms was assessed with a modified version of von Zerssen's complaints scale. Screening for lifetime diagnoses of mental disorders was performed with the Composite International Diagnostic-Screener (CID-S). Multivariable logistic regressions including several confounders were calculated. A significant protective dose-response effect of depressive symptoms on prosthetic status was found only in men for the lower jaw [0-1 depressive symptoms: odds ratio (OR) = 3.84, 95 % confidence interval (CI, 1.65-8.92), p < 0.01; 2-3: OR = 2.87 (CI, 1.22-6.74), p < 0.05; reference, ≥8; adjusted for age, school education, smoking status, household income, marital status, living without a partner, risky alcohol consumption, obesity, diabetes, and physical activity]. There was no such association in women or for the upper jaw. The analyses using the CID-S confirmed these results. In the lower jaw, men with depressive symptoms had a better prosthetic status than men without depressive symptoms suggesting a higher level of concern regarding their personal health. If dentists might have an opportunity to identify men with depressive symptoms they can provide a wide range of treatment options that may enhance patients' self-esteem and contribute to the patient' well-being. Furthermore, depressive

  19. A clinical survey about commercial games in lower limb prosthetic rehabilitation.

    PubMed

    Imam, Bita; Miller, William C; Finlayson, Heather C; Eng, Janice J; Jarus, Tal

    2018-06-01

    Despite the popularity of commercial games in lower limb prosthetic rehabilitation, data about their prevalence of use as well as therapists' perspectives about these games are still lacking. To learn about the prevalence of use of commercial games in lower limb prosthetic rehabilitation and therapists' perspectives about these games. Cross-sectional. An online survey was sent to physical and occupational therapists across prosthetic rehabilitation facilities in Canada. The survey had questions about the use of commercial games and therapists' perspectives. Data were collected from 82 therapists. Overall, 46.3% (38/82) reported that they use commercial games; of those, 94.7% (36/38) used the Nintendo Wii Fit. The most reported perceived benefits were the Wii Fit helping to improve weight shifting ( n = 76/82, 92.7%) and balance ( n = 75/82, 91.5%), and being motivating and complementing traditional therapy ( n = 75/82, 91.5%). The most reported perceived barriers/challenges were lack of time and familiarity with the games ( n = 58/82, 70.7%). Commercial games, particularly the Wii Fit, are commonly used in lower prosthetic rehabilitation in Canada. Most of the queried therapists view the Wii Fit positively. Knowledge translation activities and developing standard treatment protocols would be helpful in minimizing the barriers identified in this study. Clinical relevance The Wii Fit is prevalent in lower limb prosthetic rehabilitation in Canada and it is viewed positively by therapists as having the potential to improve balance and weight bearing, making rehabilitation more motivating, and complementing traditional therapy. Future studies should investigate the efficacy of the Wii Fit in prosthetic rehabilitation.

  20. Electrochemical Deposition of Nanostructured Conducting Polymer Coatings on Neural Prosthetic Devices

    NASA Astrophysics Data System (ADS)

    Yang, Junyan; Martin, David

    2003-03-01

    Micromachined neural prosthetic devices facilitate the functional stimulation of and recording from the central nervous system (CNS). These devices have been fabricated to consist of silicon shanks that have gold or iridium sites along their surface. Our goal is to improve the biocompatibility and long-term performance of the neural prosthetic probes when they are implanted chronically in the brain. In our most recent efforts we have established that electrochemical polymerization can be used to deposit fuzzy coatings of conducting polymers specifically on the electrode sites. For neural prosthetic devices that are intended for long term implantation, we need to develop surfaces that provide intimate contact and promote efficient signal transport at the interface of the microelectrode array and brain tissue. We have developed methods to rapidly and reliably fabricate nanostructured conducting polymer coatings on the electrode probes using templated and surfactant-mediated techniques. Conducting polymer nanomushrooms and nanohairs of polypyrrole (PPy) were electrochemically polymerized onto the functional sites of neural probes by using either nanoporous block copolymers thin films, "track-etched" polycarbonate films or anodic aluminium oxide membranes as templates. Nanofibers of conducting polymers have also been successfully obtained by polymerizations in the presence of surfactants. The influence of current density, monomer concentration, surfactant concentration, and deposition charge on the thickness and morphology of the nanostructured conducting polymer coatings has been studied by optical, scanned probe, scanning electron and transmission electron microscopy. As compared with the normal nodular morphology of polypyrrole, the nanostructured morphologies grown from the neural electrode result in fuzzy coatings with extremely high surface area. The electrical properties of the polymer coatings were studied by Impedance Spectroscopy (IS) and Cyclic Voltammetry

  1. Target of physiological gait: Realization of speed adaptive control for a prosthetic knee during swing flexion.

    PubMed

    Cao, Wujing; Yu, Hongliu; Zhao, Weiliang; Li, Jin; Wei, Xiaodong

    2018-01-01

    Prosthetic knee is the most important component of lower limb prosthesis. Speed adaptive for prosthetic knee during swing flexion is the key method to realize physiological gait. This study aims to discuss the target of physiological gait, propose a speed adaptive control method during swing flexion and research the damping adjustment law of intelligent hydraulic prosthetic knee. According to the physiological gait trials of healthy people, the control target during swing flexion is defined. A new prosthetic knee with fuzzy logical control during swing flexion is designed to realize the damping adjustment automatically. The function simulation and evaluation system of intelligent knee prosthesis is provided. Speed adaptive control test of the intelligent prosthetic knee in different velocities are researched. The maximum swing flexion of the knee angle is set between sixty degree and seventy degree as the target of physiological gait. Preliminary experimental results demonstrate that the prosthetic knee with fuzzy logical control is able to realize physiological gait under different speeds. The faster the walking, the bigger the valve closure percentage of the hydraulic prosthetic knee. The proposed fuzzy logical control strategy and intelligent hydraulic prosthetic knee are effective for the amputee to achieve physiological gait.

  2. Design and evaluation of prosthetic shoulder controller

    PubMed Central

    Barton, Joseph E.; Sorkin, John D.

    2015-01-01

    We developed a 2-degree-of-freedom (DOF) shoulder position transducer (sensing shoulder protraction-retraction and elevation-depression) that can be used to control two of a powered prosthetic humerus' DOFs. We also developed an evaluation protocol based on Fitts' law to assess the performance of our device. The primary motivation for this work was to support development of powered prosthetic shoulder joints of a new generation of prosthetic arms for people with shoulder disarticulation and very high-level transhumeral amputation. We found that transducers that provided resistance to shoulder movement performed better than those providing no resistance. We also found that a position control scheme, where effector position is proportional to shoulder position, performed better than a velocity control scheme, where effector velocity is proportional to shoulder position. More generally, our transducer can be used to control motion along any two DOFs. It can also be used in a more general 4-DOF control scheme by sequentially controlling two DOFs at a time. The evaluation protocol has general applicability for researchers and practitioners. Researchers can employ it to compare different prosthesis designs and control schemes, while practitioners may find the evaluation protocol useful in evaluating and training people with amputation in the use of prostheses. PMID:25357185

  3. Evaluation of 3D printed anatomically scalable transfemoral prosthetic knee.

    PubMed

    Ramakrishnan, Tyagi; Schlafly, Millicent; Reed, Kyle B

    2017-07-01

    This case study compares a transfemoral amputee's gait while using the existing Ossur Total Knee 2000 and our novel 3D printed anatomically scalable transfemoral prosthetic knee. The anatomically scalable transfemoral prosthetic knee is 3D printed out of a carbon-fiber and nylon composite that has a gear-mesh coupling with a hard-stop weight-actuated locking mechanism aided by a cross-linked four-bar spring mechanism. This design can be scaled using anatomical dimensions of a human femur and tibia to have a unique fit for each user. The transfemoral amputee who was tested is high functioning and walked on the Computer Assisted Rehabilitation Environment (CAREN) at a self-selected pace. The motion capture and force data that was collected showed that there were distinct differences in the gait dynamics. The data was used to perform the Combined Gait Asymmetry Metric (CGAM), where the scores revealed that the overall asymmetry of the gait on the Ossur Total Knee was more asymmetric than the anatomically scalable transfemoral prosthetic knee. The anatomically scalable transfemoral prosthetic knee had higher peak knee flexion that caused a large step time asymmetry. This made walking on the anatomically scalable transfemoral prosthetic knee more strenuous due to the compensatory movements in adapting to the different dynamics. This can be overcome by tuning the cross-linked spring mechanism to emulate the dynamics of the subject better. The subject stated that the knee would be good for daily use and has the potential to be adapted as a running knee.

  4. Rehabilitation regimes based upon psychophysical studies of prosthetic vision

    NASA Astrophysics Data System (ADS)

    Chen, S. C.; Suaning, G. J.; Morley, J. W.; Lovell, N. H.

    2009-06-01

    Human trials of prototype visual prostheses have successfully elicited visual percepts (phosphenes) in the visual field of implant recipients blinded through retinitis pigmentosa and age-related macular degeneration. Researchers are progressing rapidly towards a device that utilizes individual phosphenes as the elementary building blocks to compose a visual scene. This form of prosthetic vision is expected, in the near term, to have low resolution, large inter-phosphene gaps, distorted spatial distribution of phosphenes, restricted field of view, an eccentrically located phosphene field and limited number of expressible luminance levels. In order to fully realize the potential of these devices, there needs to be a training and rehabilitation program which aims to assist the prosthesis recipients to understand what they are seeing, and also to adapt their viewing habits to optimize the performance of the device. Based on the literature of psychophysical studies in simulated and real prosthetic vision, this paper proposes a comprehensive, theoretical training regime for a prosthesis recipient: visual search, visual acuity, reading, face/object recognition, hand-eye coordination and navigation. The aim of these tasks is to train the recipients to conduct visual scanning, eccentric viewing and reading, discerning low-contrast visual information, and coordinating bodily actions for visual-guided tasks under prosthetic vision. These skills have been identified as playing an important role in making prosthetic vision functional for the daily activities of their recipients.

  5. Re-operation for aortic and mitral prosthetic dysfunctions.

    PubMed

    Kaul, T K; Sastry, M R; Mercer, J L; Meade, J B

    1985-01-01

    The overall incidence of re-operation and prosthetic valve endocarditis was low in the present series as mechanical prostheses were used predominantly. The prosthetic dysfunctions were less frequent following the primary implantation with Bjork Shiley prostheses, but high operative risk was associated with the clotted Bjork Shiley prostheses. We also had unusual experience of strut fracture and sticking of Bjork Shiley discs in the closed position in both aortic and mitral positions. The early deaths were nil since the use of cardioplegic protection. Intra-operative bleeding due to adhesions can be minimised by using synthetic or heterologous pericardium during the primary operation.

  6. Prosthetic urinary sphincter

    NASA Technical Reports Server (NTRS)

    Helms, C. R.; Smyly, H. M. (Inventor)

    1981-01-01

    A pump/valve unit for controlling the inflation and deflation of a urethral collar in a prosthetic urinary sphincter device is described. A compressible bulb pump defining a reservoir was integrated with a valve unit for implantation. The valve unit includes a movable valve member operable by depression of a flexible portion of the valve unit housing for controlling fluid flow between the reservoir and collar; and a pressure sensing means which operates the valve member to relieve an excess pressure in the collar should too much pressure be applied by the patient.

  7. Capnocytophaga canimorsus: a rare case of conservatively treated prosthetic valve endocarditis.

    PubMed

    Jalava-Karvinen, Päivi; Grönroos, Juha O; Tuunanen, Helena; Kemppainen, Jukka; Oksi, Jarmo; Hohenthal, Ulla

    2018-05-01

    We describe a rare case of prosthetic valve endocarditis caused by the canine bacterium Capnocytophaga canimorsus in a male aged 73 years. The diagnosis of infective endocarditis was unequivocal, as it blood cultures were positive for C. canimorsus and vegetations were detected on transesophageal echocardiography; the modified Duke criteria were fulfilled. PET-CT showed intense 18 F-FDG uptake of the prosthetic valve area. The patient was treated with antibiotics alone (no surgery), and is now on life-long suppressive antibiotic therapy. To our knowledge, this is the third reported case of prosthetic valve endocarditis caused by C. canimorsus and the first one to have been treated conservatively. © 2018 APMIS. Published by John Wiley & Sons Ltd.

  8. Wireless Microstimulators for Neural Prosthetics

    PubMed Central

    Sahin, Mesut; Pikov, Victor

    2016-01-01

    One of the roadblocks in the field of neural prosthetics is the lack of microelectronic devices for neural stimulation that can last a lifetime in the central nervous system. Wireless multi-electrode arrays are being developed to improve the longevity of implants by eliminating the wire interconnects as well as the chronic tissue reactions due to the tethering forces generated by these wires. An area of research that has not been sufficiently investigated is a simple single-channel passive microstimulator that can collect the stimulus energy that is transmitted wirelessly through the tissue and immediately convert it into the stimulus pulse. For example, many neural prosthetic approaches to intraspinal microstimulation require only a few channels of stimulation. Wired spinal cord implants are not practical for human subjects because of the extensive flexions and rotations that the spinal cord experiences. Thus, intraspinal microstimulation may be a pioneering application that can benefit from submillimetersize floating stimulators. Possible means of energizing such a floating microstimulator, such as optical, acoustic, and electromagnetic waves, are discussed. PMID:21488815

  9. Remote transient Lactobacillus animalis bacteremia causing prosthetic hip joint infection: a case report.

    PubMed

    Somayaji, R; Lynch, T; Powell, J N; Gregson, D

    2016-11-04

    Lactobacillus spp. are uncommon pathogens in immunocompetent hosts, and even rarer causes of prosthetic device infections. A case of chronic hip prosthetic joint infection (PJI) caused by L. animalis is described. This occurred 5 years after a transient bacteremia with the same organism. Whole genome sequencing of both isolates proved this PJI infection resulted from this remote bacteremia. We document that prosthetic joint infections may be a consequence of bacteremia as much as 3 years before the onset of symptoms.

  10. Trends in Penile Prosthetics: Influence of Patient Demographics, Surgeon Volume, and Hospital Volume on Type of Penile Prosthesis Inserted in New York State.

    PubMed

    Kashanian, James A; Golan, Ron; Sun, Tianyi; Patel, Neal A; Lipsky, Michael J; Stahl, Peter J; Sedrakyan, Art

    2018-02-01

    Penile prostheses (PPs) are a discrete, well-tolerated treatment option for men with medical refractory erectile dysfunction. Despite the increasing prevalence of erectile dysfunction, multiple series evaluating inpatient data have found a decrease in the frequency of PP surgery during the past decade. To investigate trends in PP surgery and factors affecting the choice of different PPs in New York State. This study used the New York State Department of Health Statewide Planning and Research Cooperative (SPARCS) data cohort that includes longitudinal information on hospital discharges, ambulatory surgery, emergency department visits, and outpatient services. Patients older than 18 years who underwent inflatable or non-inflatable PP insertion from 2000 to 2014 were included in the study. Influence of patient demographics, surgeon volume, and hospital volume on type of PP inserted. Since 2000, 14,114 patients received PP surgery in New York State; 12,352 PPs (88%) were inflatable and 1,762 (12%) were non-inflatable, with facility-level variation from 0% to 100%. There was an increasing trend in the number of annual procedures performed, with rates of non-inflatable PP insertion decreasing annually (P < .01). More procedures were performed in the ambulatory setting over time (P < .01). Important predictors of device choice were insurance type, year of insertion, hospital and surgeon volume, and the presence of comorbidities. Major influences in choice of PP inserted include racial and socioeconomic factors and surgeon and hospital surgical volume. Use of the SPARCS database, which captures inpatient and outpatient services, allows for more accurate insight into trends in contrast to inpatient sampling alone. However, SPARCS is limited to patients within New York State and the results might not be generalizable to men in other states. Also, patient preference was not accounted for in these analyses, which can play a role in PP selection. During the past 14 years, there

  11. Design of a novel prosthetic socket: assessment of the thermal performance.

    PubMed

    Webber, Christina M; Davis, Brian L

    2015-05-01

    Prosthetic liners and sockets insulate the residual limb, causing excessive sweating and concomitant skin maceration. When coupled with atypical loading conditions, further dermatologic problems can arise. This can significantly reduce the quality of life of an amputee patient. Improving the design of the prosthetic socket has been proposed as a means of reestablishing a normal thermal environment around the residual limb. In this study, a prosthetic socket was modified by incorporating a helical cooling channel within the socket wall using additive manufacturing techniques. Two sockets were modeled: a control socket, and a modified socket containing a 0.48 cm diameter cooling channel. Computer simulations and bench-top testing were used to assess the design's ability to create a greater temperature differential across the socket wall. A greater temperature drop across the socket wall suggested that the socket could provide cooling benefits to the residual limb by allowing for heat to be drawn away from the limb. The temperature difference across the socket wall was calculated for both sockets in each aspect of the study. Both socket type (p=0.002) and location on the socket (p=0.014) were statistically significant factors affecting the temperature difference between inner and outer socket walls. Compared with the control socket, the modified socket containing a helical cooling channel exhibited greater temperature differences across its wall of 11.1 °C and 6.4 °C in the computer simulations and bench-top testing, respectively. This finding suggested that socket modifications, such as the cooling channel presented, could provide a beneficial cooling effect to an amputee patient's residual limb. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. [Virtual Planning of Prosthetic Treatment of the Orbit].

    PubMed

    Veit, Johannes A; Thierauf, Julia; Egner, Kornelius; Wiggenhauser, Paul Severin; Friedrich, Daniel; Greve, Jens; Schuler, Patrick J; Hoffmann, Thomas K; Schramm, Alexander

    2017-06-01

    Optimal positioning of bone-anchored implants in the treatment of patients with orbital prosthesis is challenging. The definition of implant axis as well as the positioning of the implants is important to prevent failures in prosthetic rehabilitation in these patients. We performed virtual planning of enossal implants at a base of a standard fan beam CT scan using the software CoDiagnostiX™ (DentalWings, Montréal, Canada). By 3D-printing a surgical guide for drilling and implant insertion was manufactured (Med-610™, Stratasys, Rehovot, Israel). An orbital exenteration was performed in a patient after shrinkage of the eyelids 20 years after enucleation and radiation of the orbit due to rhabdomyosarcoma. 4 Vistafix-3 implants (Cochlear™, Cochlea, Centennial, USA) were primarily inserted after resection with the help of the 3D-surgical guide. Prosthetic rehabilitation could be achieved as preplanned to a predictable result. The individual prosthesis of the orbit showed good functional and esthetic outcome. The virtual 3D-planning of endosseous implants for prosthetic orbital and periorbital reconstruction is easy to use and facilitates optimal placement of implants especially in posttherapeutically altered anatomic situations. © Georg Thieme Verlag KG Stuttgart · New York.

  13. Development of inexpensive prosthetic feet for high-heeled shoes using simple shoe insole model.

    PubMed

    Meier, Margrit R; Tucker, Kerice A; Hansen, Andrew H

    2014-01-01

    The large majority of prosthetic feet are aimed at low-heeled shoes, with a few models allowing a heel height of up to 5 cm. However, a survey by the American Podiatric Medical Association indicates that most women wear heels over 5 cm; thus, current prosthetic feet limit most female prosthesis users in their choice. Some prosthetic foot components are heel-height adjustable; however, their plantar surface shapes do not change to match the insole shapes of the shoes with different heel heights. The aims of the study were therefore (1) to develop a model that allows prediction of insole shape for various heel height shoes in combination with different shoe sizes and (2) to develop and field-test low-cost prototypes of prosthetic feet whose insole shapes were based on the new model. An equation was developed to calculate insole shapes independent of shoe size. Field testing of prototype prosthetic feet fabricated based on the equation was successful and demonstrated the utility of the equation.

  14. Development of a Prototype Over-Actuated Biomimetic Prosthetic Hand

    PubMed Central

    Williams, Matthew R.; Walter, Wayne

    2015-01-01

    The loss of a hand can greatly affect quality of life. A prosthetic device that can mimic normal hand function is very important to physical and mental recuperation after hand amputation, but the currently available prosthetics do not fully meet the needs of the amputee community. Most prosthetic hands are not dexterous enough to grasp a variety of shaped objects, and those that are tend to be heavy, leading to discomfort while wearing the device. In order to attempt to better simulate human hand function, a dexterous hand was developed that uses an over-actuated mechanism to form grasp shape using intrinsic joint mounted motors in addition to a finger tendon to produce large flexion force for a tight grip. This novel actuation method allows the hand to use small actuators for grip shape formation, and the tendon to produce high grip strength. The hand was capable of producing fingertip flexion force suitable for most activities of daily living. In addition, it was able to produce a range of grasp shapes with natural, independent finger motion, and appearance similar to that of a human hand. The hand also had a mass distribution more similar to a natural forearm and hand compared to contemporary prosthetics due to the more proximal location of the heavier components of the system. This paper describes the design of the hand and controller, as well as the test results. PMID:25790306

  15. Oral health-related quality of life and prosthetic status of nursing home residents with or without dementia.

    PubMed

    Klotz, Anna-Luisa; Hassel, Alexander Jochen; Schröder, Johannes; Rammelsberg, Peter; Zenthöfer, Andreas

    2017-01-01

    The objective of this cross-sectional study was to evaluate the effect of prosthetic status on the oral health-related quality of life (OHRQoL) of nursing home residents with or without dementia. The study was performed in 14 nursing homes across the federal state of Baden-Württemberg, Germany. All eligible participants were included, and general and medical information and information about their dental and prosthetic statuses were collected. The Geriatric Oral Health Assessment Index (GOHAI) was administered to evaluate OHRQoL. The Mini-Mental State Examination (MMSE) served to classify participants into living or not living with dementia according to the established cutoff value for dementia (MMSE <24). Parametric bivariate statistics and logistic regression models were used to analyze data at P <0.05. A total of 169 participants were included in this study. The mean age of the participants was 82.9 years. A total of some 70% of the sample was living with dementia. The mean GOHAI score along the sample was 49.1 (8.3), and 41% of the sample reported substantially compromised OHRQoL (GOHAI <50). OHRQoL was statistically similar for people with or without dementia ( P =0.234); objective oral health was also similar in both groups ( P >0.05). The number of teeth (odds ratio [OR]: 2.0), the type of prosthetic status (OR: 6.5), and denture-related treatment needs (OR: 2.4) were the major factors significantly affecting OHRQoL ( P <0.05). The OHRQoL of elderly nursing home residents is substantially compromised. Several prosthetic treatment needs for residents living with or without dementia were identified. Edentulism without tooth replacement and having <5 teeth resulted in an increased risk of substantially compromised OHRQoL. Further studies should be conducted to determine whether improvements in prosthetic status can increase OHRQoL.

  16. Candida Prosthetic Joint Infection. A Review of Treatment Methods.

    PubMed

    Cobo, Fernando; Rodríguez-Granger, Javier; Sampedro, Antonio; Aliaga-Martínez, Luis; Navarro-Marí, José María

    2017-01-01

    Fungal microorganisms are still a rare cause of bone and joint infections. We report a new case of knee prosthetic joint infection due to Candida albicans in a patient with a previous two-stage right knee arthroplasty for septic arthritis due to S. epidermidis occurred several months ago. Moreover, the treatment in 76 cases of Candida prosthetic joint infection has been discussed. Forty patients were female and mean age at diagnosis was 65.7 (± SD 18) yrs. No risk factors for candidal infection were found in 25 patients. Infection site was the knee in 38 patients and hip in 36; pain was present in 44 patients and swelling in 24. The most frequent species was C. albicans , followed by C. parapsilosis . Eleven patients were only treated with antifungal drugs being the outcome favourable in all of them. Two-stage exchange arthroplasty was performed in 30 patients, and resection arthroplasty in other 30; in three patients one-stage exchange arthroplasty was done. A favourable outcome was found in 58 patients after antifungal plus surgical treatment, in 11 after antifungal treatment alone and in one after surgery alone. The type of treatment is still not clearly defined and an algorithm for treatment in fungal PJI should be established, but various types of surgical procedures may be applied.

  17. Bar-holding prosthetic limb

    NASA Technical Reports Server (NTRS)

    Vest, Thomas W. (Inventor); Norton, William E. (Inventor); Belcher, Jewell G. (Inventor); Carden, James R. (Inventor)

    1992-01-01

    A prosthetic device for below-the-elbow amputees is disclosed. The device has a removable effector, which is attached to the end of an arm cuff. The effector is comprised of a pair of C-shaped members that are oriented so as to face each other. Working in concert, the C-shaped members are able to hold a bar such as a chainsaw handle. A flat spring is fitted around the C-shaped members to hold them together.

  18. [Natural factors influencing sleep].

    PubMed

    Jurkowski, Marek K; Bobek-Billewicz, Barbara

    2007-01-01

    Sleep is a universal phenomenon of human and animal lives, although the importance of sleep for homeo-stasis is still unknown. Sleep disturbances influence many behavioral and physiologic processes, leading to health complications including death. On the other hand, sleep improvement can beneficially influence the course of healing of many disorders and can be a prognostic of health recovery. The factors influencing sleep have different biological and chemical origins. They are classical hormones, hypothalamic releasing and inhibitory hormones, neuropeptides, peptides and others as cytokines, prostaglandins, oleamid, adenosine, nitric oxide. These factors regulate most physiologic processes and are likely elements integrating sleep with physiology and physiology with sleep in health and disorders.

  19. The effect of anti-gravity treadmill training for prosthetic rehabilitation of a case with below-knee amputation.

    PubMed

    Mikami, Yukio; Fukuhara, Kouki; Kawae, Toshihiro; Kimura, Hiroaki; Ochi, Mitsuo

    2015-12-01

    The aim of this case study was to verify the efficacy and safety of anti-gravity treadmill training for prosthetic rehabilitation following below-knee amputation. The patient underwent left below-knee amputation as a result of diabetic foot gangrene. Since his physical strength and vitality had declined during the perioperative period, anti-gravity treadmill training was introduced for his outpatient prosthetic rehabilitation. Stable prosthetic gait exercise could be carried out under guidance on the anti-gravity treadmill, quickly resulting in improved gait. Furthermore, the patient's self-efficacy and exercise tolerance were elevated after the period of anti-gravity treadmill training. At the final evaluation following 6 weeks of rehabilitation with the anti-gravity treadmill, he had acquired prosthetic gait with the assistance of a T-cane. The anti-gravity treadmill was found to be a useful instrument for prosthetic rehabilitation following below-knee amputation. Anti-gravity treadmill training has the potential to support the prosthetic rehabilitation of below-knee amputees, especially for patients whose physical strength and vitality are decreased. © The International Society for Prosthetics and Orthotics 2014.

  20. Rapidly growing non-tuberculous mycobacteria infection of prosthetic knee joints: A report of two cases.

    PubMed

    Kim, Manyoung; Ha, Chul-Won; Jang, Jae Won; Park, Yong-Beom

    2017-08-01

    Non-tuberculous mycobacteria (NTM) cause prosthetic knee joint infections in rare cases. Infections with rapidly growing non-tuberculous mycobacteria (RGNTM) are difficult to treat due to their aggressive clinical behavior and resistance to antibiotics. Infections of a prosthetic knee joint by RGNTM have rarely been reported. A standard of treatment has not yet been established because of the rarity of the condition. In previous reports, diagnoses of RGNTM infections in prosthetic knee joints took a long time to reach because the condition was not suspected, due to its rarity. In addition, it is difficult to identify RGNTM in the lab because special identification tests are needed. In previous reports, after treatment for RGNTM prosthetic infections, knee prostheses could not be re-implanted in all cases but one, resulting in arthrodesis or resection arthroplasty; this was most likely due to the aggressiveness of these organisms. In the present report, two cases of prosthetic knee joint infection caused by RGNTM (Mycobacterium abscessus) are described that were successfully treated, and in which prosthetic joints were finally reimplanted in two-stage revision surgery. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Analysis of maxillofacial prosthetics at university dental hospitals in the capital region of Korea

    PubMed Central

    Lee, Jong-Ho

    2016-01-01

    PURPOSE The purpose of this study was to investigate the demographic patterns of maxillofacial prosthetic treatment to identify the characteristics and geographic distribution of patients with maxillofacial prosthetics in the capital region of Korea. MATERIALS AND METHODS This retrospective analytical multicenter study was performed by chart reviews. This study included patients who visited the department of prosthodontics at four university dental hospitals for maxillofacial prosthetic rehabilitation. Patients with facial and congenital defects or with insufficient medical data were excluded. The patients were classified into three categories based on the location of the defect. Patients' sex, age, and residential area were analyzed. Pearson's chi-square test with a significance level of 0.05 was used to analyze the variables. RESULTS Among 540 patients with maxillofacial prosthetics, there were 284 (52.59%) male patients and 256 (47.41%) female patients. The number of the patients varied greatly by hospital. Most patients were older than 70, and the most common defect was a hard palate defect. Chi-square analysis did not identify any significant differences in sex, age, and distance to hospital for any defect group (P>.05). CONCLUSION The results of this study indicated that there was imbalance in the distribution of patients with maxillofacial prosthetic among the hospitals in the capital region of Korea. Considerations on specialists and insurance policies for the improvement of maxillofacial prosthetics in Korea are required. PMID:27350859

  2. Implementing a new curriculum for computer-assisted restorations in prosthetic dentistry.

    PubMed

    Schweyen, R; Beuer, F; Bochskanl, M; Hey, J

    2018-05-01

    Computer-aided design/computer-aided manufacturing (CAD/CAM) of fixed prosthetic restorations has gained popularity in the last decade. However, this field of dentistry has not been integrated in the dental curriculum at most universities. According to the method of Kern, a curriculum was designed and established on a voluntary basis in the prosthetic education of a German dental school. The success of the implementation was measured by evaluation carried out by the participants on a visual analogue scale. Furthermore, the clinical performance of the fabricated restorations was evaluated. Ninety-four percent of all students participated in the CAD/CAM curriculum indicating considerable interest. Nearly half of all students used the acquired knowledge to design crowns for their patients. All restorations fabricated by participants of the new CAD/CAM programme showed good clinical performance. By phasing-in the CAD/CAM training programme, independent CAD/CAM-based fabrication of all-ceramic crowns increased student's self-confidence in tooth preparation. A tendency was found that students using CAD/CAM technology prepared more teeth than their fellow students who did not use CAD/CAM technology. Further studies are required to investigate the influence of independent CAD/CAM-based single-crown fabrication on the quality of the preparation. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. Prosthetics socket that incorporates an air splint system focusing on dynamic interface pressure.

    PubMed

    Razak, Nasrul Anuar Abd; Osman, Noor Azuan Abu; Gholizadeh, Hossein; Ali, Sadeeq

    2014-08-01

    The interface pressure between the residual limb and prosthetic socket has a significant effect on an amputee's satisfaction and comfort. This paper presents the design and performance of a new prosthetic socket that uses an air splint system. The air splint prosthetic socket system was implemented by combining the air splint with a pressure sensor that the transhumeral user controls through the use of a microcontroller. The modular construction of the system developed allows the FSR pressure sensors that are placed inside the air splint socket to determine the required size and fitting for the socket used. Fifteen transhumeral amputees participated in the study. The subject's dynamic pressure on the socket that's applied while wearing the air splint systems was recorded using F-socket transducers and microcontroller analysis. The values collected by the F-socket sensor for the air splint prosthetic socket system were determined accordingly by comparing the dynamic pressure applied using statically socket. The pressure volume of the air splint fluctuated and was recorded at an average of 38 kPa (2.5) to 41 kPa (1.3) over three hours. The air splint socket might reduce the pressure within the interface of residual limb. This is particularly important during the daily life activities and may reduce the pain and discomfort at the residual limb in comparison to the static socket. The potential development of an auto-adjusted socket that uses an air splint system as the prosthetic socket will be of interest to researchers involved in rehabilitation engineering, prosthetics and orthotics.

  4. [Prosthetic bilateral laparoscopic hernioplasty. Extra-peritoneal approach].

    PubMed

    Rossi, M; Castoro, C; Zaninotto, G; Comandella, M G; Polo, R; Nolli, M L; Ancona, E

    1997-03-01

    The use of prosthetic mesh in inguinal hernia repairs is becoming increasingly popular. In recent years different laparoscopic procedures for prosthetic repair of inguinal hernias have been developed. The authors describe their initial experience with a totally extra-peritoneal prosthetic approach in laparoscopic repair of bilateral inguinal hernias. From November 1993 to May 1994, ten consecutive patients with bilateral primary inguinal hernias underwent laparoscopic repair under general anesthesia. A totally extra-peritoneal approach has been performed beginning through a 2 centimeter vertical midline sub-umbilical incision. Two additional trocars have been inserted on the midline: a 10/12 mm one halfway between the umbilicus and the pubis and 5 mm one 2 cm above the pubis. Average operative time was 141 minutes. Two cases were converted to traditional open Stoppa procedure because of holes made in the peritoneum during blunt dissection of the hernia sac. In the remaining 8 cases a polypropylene mesh of about 8 cm in height and 13 cm in length have been placed on each hernia site. No major complications have been observed and recovery was quick in all cases. In conclusion we think that laparoscopic hernia repair through a totally extra-peritoneal approach is technically feasible for general surgeons trained in laparoscopic surgery. Nevertheless the operation in costly and the patient's benefit in terms of rapid recovery, complications and recurrences has not yet been demonstrated in controlled prospective trials.

  5. A global perspective on mechanical prosthetic heart valve thrombosis: Diagnostic and therapeutic challenges

    PubMed Central

    Gürsoy, Mustafa Ozan; Kalçık, Macit; Yesin, Mahmut; Karakoyun, Süleyman; Bayam, Emrah; Gündüz, Sabahattin; Özkan, Mehmet

    2016-01-01

    Prosthetic valve thrombosis is one of the major causes of primary valve failure, which can be life-threatening. Multimodality imaging is necessary for determination of leaflet immobilization, cause of underlying pathology (thrombus versus pannus or both), and whether thrombolytic therapy attempt in the patient would be successful or surgery is needed. Current guidelines for the management of prosthetic valve thrombosis lack definitive class I recommendations due to lack of randomized controlled trials, and usually leave the choice of treatment to the clinician’s experience. In this review, we aimed to summarize the pathogenesis, diagnosis, and management of mechanical prosthetic valve thrombosis. PMID:28005024

  6. Experimental measurement of flexion-extension movement in normal and corpse prosthetic elbow joint.

    PubMed

    TarniŢă, Daniela; TarniŢă, DănuŢ Nicolae

    2016-01-01

    This paper presents a comparative experimental study of flexion-extension movement in healthy elbow and in the prosthetic elbow joint fixed on an original experimental bench. Measurements were carried out in order to validate the functional morphology and a new elbow prosthesis type ball head. The three-dimensional (3D) model and the physical prototype of our experimental bench used to test elbow endoprosthesis at flexion-extension and pronation-supination movements is presented. The measurements were carried out on a group of nine healthy subjects and on the prosthetic corpse elbow, the experimental data being obtained for flexion-extension movement cycles. Experimental data for the two different flexion-extension tests for the nine subjects and for the corpse prosthetic elbow were acquired using SimiMotion video system. Experimental data were processed statistically. The corresponding graphs were obtained for all subjects in the experimental group, and for corpse prosthetic elbow for both flexion-extension tests. The statistical analysis has proved that the flexion angles of healthy elbows were significantly close to the values measured at the prosthetic elbow fixed on the experimental bench. The studied elbow prosthesis manages to re-establish the mobility for the elbow joint as close to the normal one.

  7. Speech and Swallowing Data in Individual Patients Who Underwent Glossectomy after Prosthetic Rehabilitation

    PubMed Central

    Sennes, Luiz Ubirajara

    2016-01-01

    Maintaining oral function in patients undergoing glossectomy boosts interventions such as prosthetic rehabilitation. However, current literature still fails in the presentation of results of prosthetic rehabilitation in relation to speech or swallowing. The objective of this research is to evaluate the effectiveness of prosthetic rehabilitation on voice, speech, and swallowing in patients undergoing glossectomy by performing a systematic literature review and meta-analysis of individual cases. Studies were identified by relevant electronic database and included all dates available. The criteria used were sample with any n; resection due to malignant tumors, restricted to tongue and/or floor of mouth; type of prosthetic rehabilitation; and description of the oral functions outcomes with prosthesis. For the meta-analysis of individual data, associations between the variables of interest and the type of prosthesis were evaluated. Thirty-three of 471 articles met the selection criteria. Results on speech and/or voice and swallowing were reported in 27 and 28 articles, respectively. There were improvement of speech intelligibility and swallowing in 96 patients and in 73 patients, respectively, with prosthesis. Based on the available evidences, this article showed that prosthetic rehabilitation was able to improve oral functions and can be a strategy used with surgical reconstruction in selected cases. PMID:28042295

  8. The Effect of Prosthetic Foot Push-off on Mechanical Loading Associated with Knee Osteoarthritis in Lower Extremity Amputees

    PubMed Central

    Morgenroth, David C.; Segal, Ava D.; Zelik, Karl E.; Czerniecki, Joseph M.; Klute, Glenn K.; Adamczyk, Peter G.; Orendurff, Michael S.; Hahn, Michael E.; Collins, Steven H.; Kuo, Art D.

    2011-01-01

    Lower extremity amputation not only limits mobility, but also increases the risk of knee osteoarthritis of the intact limb. Dynamic walking models of non-amputees suggest that pushing-off from the trailing limb can reduce collision forces on the leading limb. These collision forces may determine the peak knee external adduction moment (EAM), which has been linked to the development of knee OA in the general population. We therefore hypothesized that greater prosthetic push-off would lead to reduced loading and knee EAM of the intact limb in unilateral transtibial amputees. Seven unilateral transtibial amputees were studied during gait under three prosthetic foot conditions that were intended to vary push-off. Prosthetic foot-ankle push-off work, intact limb knee EAM and ground reaction impulses for both limbs during step-to-step transition were measured. Overall, trailing limb prosthetic push-off work was negatively correlated with leading intact limb 1st peak knee EAM (slope = −0.72 +/− 0.22; p=0.011). Prosthetic push-off work and 1st peak intact knee EAM varied significantly with foot type. The prosthetic foot condition with the least push-off demonstrated the largest knee EAM, which was reduced by 26% with the prosthetic foot producing the most push-off. Trailing prosthetic limb push-off impulse was negatively correlated with leading intact limb loading impulse (slope = −0.34 +/− 0.14; p=.001), which may help explain how prosthetic limb push-off can affect intact limb loading. Prosthetic feet that perform more prosthetic push-off appear to be associated with a reduction in 1st peak intact knee EAM, and their use could potentially reduce the risk and burden of knee osteoarthritis in this population. PMID:21803584

  9. The effect of prosthetic foot push-off on mechanical loading associated with knee osteoarthritis in lower extremity amputees.

    PubMed

    Morgenroth, David C; Segal, Ava D; Zelik, Karl E; Czerniecki, Joseph M; Klute, Glenn K; Adamczyk, Peter G; Orendurff, Michael S; Hahn, Michael E; Collins, Steven H; Kuo, Art D

    2011-10-01

    Lower extremity amputation not only limits mobility, but also increases the risk of knee osteoarthritis of the intact limb. Dynamic walking models of non-amputees suggest that pushing-off from the trailing limb can reduce collision forces on the leading limb. These collision forces may determine the peak knee external adduction moment (EAM), which has been linked to the development of knee OA in the general population. We therefore hypothesized that greater prosthetic push-off would lead to reduced loading and knee EAM of the intact limb in unilateral transtibial amputees. Seven unilateral transtibial amputees were studied during gait under three prosthetic foot conditions that were intended to vary push-off. Prosthetic foot-ankle push-off work, intact limb knee EAM and ground reaction impulses for both limbs during step-to-step transition were measured. Overall, trailing limb prosthetic push-off work was negatively correlated with leading intact limb 1st peak knee EAM (slope=-.72±.22; p=.011). Prosthetic push-off work and 1st peak intact knee EAM varied significantly with foot type. The prosthetic foot condition with the least push-off demonstrated the largest knee EAM, which was reduced by 26% with the prosthetic foot producing the most push-off. Trailing prosthetic limb push-off impulse was negatively correlated with leading intact limb loading impulse (slope=-.34±.14; p=.001), which may help explain how prosthetic limb push-off can affect intact limb loading. Prosthetic feet that perform more prosthetic push-off appear to be associated with a reduction in 1st peak intact knee EAM, and their use could potentially reduce the risk and burden of knee osteoarthritis in this population. Published by Elsevier B.V.

  10. Quality of Life in Patients After Maxillectomy and Placement of Prosthetic Obturator.

    PubMed

    Chen, Cheng; Ren, Wen-Hao; Huang, Rui-Zhe; Gao, Ling; Hu, Zhi-Ping; Zhang, Lin-Mei; Li, Shao-Ming; Dong, Kai; Qi, Hong; Zhi, Ke-Qian

    2016-01-01

    The aim of this study was to assess quality of life (QoL) and obturator functioning in patients having undergone a maxillectomy as a tumor ablative resection and rehabilitation with a prosthetic obturator. The University of Washington Quality of Life scale version 4 (UW-QoLv4) and the Obturator Functioning Scale (OFS) were used to evaluate the self-reported QoL and obturator functioning. The effects of demographic and treatment variables on QoL were assessed using age, defect size, postoperative radiotherapy (RT), neck dissection, and dentition. The study included 16 men and 13 women with a mean age of 48.8 years. Of the 29 patients, 16 had a Brown Class 2a or smaller defect and 13 had a Brown Class 2b or larger defect. The mean OFS score (P = .004) and the physical (P = .001) and social-emotional function scores (P = .001) of the patients who received postoperative RT were significantly lower than those who did not receive postoperative RT. The subscales for swallowing (P = .008), saliva (P = .001), pain (P = .001), and shoulder function (P = .002) correlated strongly with postoperative RT on the UW-QoL. The subscales for pronunciation (P = .007) and saliva (P = .002) correlated significantly with RT on the OFS. The mean OFS scores were significantly lower for the patients with a Brown Class 2a or smaller defect than for Brown Class 2b or larger (P = .005). Postoperative RT was the strongest variable affecting QoL in patients with maxillectomy and prosthetic obturator reconstruction. The size of the defect slightly influenced the obturator function; however, it did not influence the overall QoL.

  11. Prosthetic valve endocarditis: who needs surgery? A multicentre study of 104 cases

    PubMed Central

    Habib, G; Tribouilloy, C; Thuny, F; Giorgi, R; Brahim, A; Amazouz, M; Remadi, J-P; Nadji, G; Casalta, J-P; Coviaux, F; Avierinos, J-F; Lescure, X; Riberi, A; Weiller, P-J; Metras, D; Raoult, D

    2005-01-01

    Objectives: To identify the prognostic markers of a bad outcome in a large population of 104 patients with prosthetic valve endocarditis (PVE), and to study the influence of medical versus surgical strategy on outcome in PVE and thus to identify patients for whom surgery may be beneficial. Design: Multicentre study. Methods and results: Among 104 patients, 22 (21%) died in hospital. Factors associated with in-hospital death were severe co-morbidity (6% of survivors v 41% of those who died, p  =  0.05), renal failure (28% v 45%, p  =  0.05), moderate to severe regurgitation (22% v 54%, p  =  0.006), staphylococcal infection (16% v 54%, p  =  0.001), severe heart failure (22% v 64%, p  =  0.001), and occurrence of any complication (60% v 90%, p  =  0.05). By multivariate analysis, severe heart failure (odds ratio 5.5) and Staphylococcus aureus infection (odds ratio 6.1) were the only independent predictors of in-hospital death. Among 82 in-hospital survivors, 21 (26%) died during a 32 month follow up. A Cox proportional hazards model identified early PVE, co-morbidity, severe heart failure, staphylococcus infection, and new prosthetic dehiscence as independent predictors of long term mortality. Mortality was not significantly different between surgical and non-surgical patients (17% v 25%, respectively, not significant). However, both in-hospital and long term mortality were reduced by a surgical approach in high risk subgroups of patients with staphylococcal PVE and complicated PVE. Conclusions: Firstly, PVE not only carries a high in-hospital mortality risk but also is associated with high long term mortality and needs close follow up after the initial episode. Secondly, congestive heart failure, early PVE, staphylococcal infection, and complicated PVE are associated with a bad outcome. Thirdly, subgroups of patients could be identified for whom surgery is associated with a better outcome: patients with staphylococcal and complicated PVE

  12. Alternative causes of bioreaction to prosthetic heart valves: three cases with pannus formation.

    PubMed

    Karakoyun, Süleyman; Gürsoy, Ozan Mustafa; Kalçık, Macit; Coban Kökten, Sermin; Ozkan, Mehmet

    2014-01-01

    Pannus formation is an infrequent but serious complication of prosthetic heart valve surgery. The cause of pannus is recognized as a bioreaction to the prostheses; histological investigations have shown that pannus comprises collagen and elastic tissues containing endothelial cells, chronic inflammatory cells, and myofibroblasts. However, the detailed mechanism of its formation has not been fully demonstrated. We aimed to evaluate the potential role of vascular endothelial growth factor (VEGF) and matrix metalloproteinase-2 (MMP-2) in the pathogenesis of pannus formation in three patients with mechanical prosthetic heart valves. Pannus specimens removed from the prostheses were fixed in 10% neutral-buffered formalin for 24 hours after surgical removal and paraffin-embedded using standard procedures. Serial sections were cut at 4 µm for immunohistochemistry analysis. Hematoxylin and eosin (HE) was used in the histological analysis. VEGF and MMP-2 were studied in the immunohistochemistry analysis. Three patients with mechanical prosthetic obstruction due to pannus overgrowth underwent redo valve surgery. In the first and second patients, the mitral prosthesis was explanted along with the pannus overgrowth. The third patient had both aortic and mitral prostheses; the aortic prosthesis was explanted with obstructive pannus formation, whereas the mitral valve was spared with excision of the nonobstructive pannus. The immunohistochemical study demonstrated the expressions of MMP-2 and VEGF in all of the pannus specimens acquired from these cases. VEGF and MMP-2 may play a role in the mechanism of pannus formation as the elements of the chronic active inflammatory process.

  13. Can We Achieve Intuitive Prosthetic Elbow Control Based on Healthy Upper Limb Motor Strategies?

    PubMed Central

    Merad, Manelle; de Montalivet, Étienne; Touillet, Amélie; Martinet, Noël; Roby-Brami, Agnès; Jarrassé, Nathanaël

    2018-01-01

    Most transhumeral amputees report that their prosthetic device lacks functionality, citing the control strategy as a major limitation. Indeed, they are required to control several degrees of freedom with muscle groups primarily used for elbow actuation. As a result, most of them choose to have a one-degree-of-freedom myoelectric hand for grasping objects, a myoelectric wrist for pronation/supination, and a body-powered elbow. Unlike healthy upper limb movements, the prosthetic elbow joint angle, adjusted prior to the motion, is not involved in the overall upper limb movements, causing the rest of the body to compensate for the lack of mobility of the prosthesis. A promising solution to improve upper limb prosthesis control exploits the residual limb mobility: like in healthy movements, shoulder and prosthetic elbow motions are coupled using inter-joint coordination models. The present study aims to test this approach. A transhumeral amputated individual used a prosthesis with a residual limb motion-driven elbow to point at targets. The prosthetic elbow motion was derived from IMU-based shoulder measurements and a generic model of inter-joint coordinations built from healthy individuals data. For comparison, the participant also performed the task while the prosthetic elbow was implemented with his own myoelectric control strategy. The results show that although the transhumeral amputated participant achieved the pointing task with a better precision when the elbow was myoelectrically-controlled, he had to develop large compensatory trunk movements. Automatic elbow control reduced trunk displacements, and enabled a more natural body behavior with synchronous shoulder and elbow motions. However, due to socket impairments, the residual limb amplitudes were not as large as those of healthy shoulder movements. Therefore, this work also investigates if a control strategy whereby prosthetic joints are automatized according to healthy individuals' coordination models can

  14. Current strategies with 1-stage prosthetic breast reconstruction

    PubMed Central

    2015-01-01

    Background 1-stage prosthetic breast reconstruction is gaining traction as a preferred method of breast reconstruction in select patients who undergo mastectomy for cancer or prevention. Methods Critical elements to the procedure including patient selection, technique, surgical judgment, and postoperative care were reviewed. Results Outcomes series reveal that in properly selected patients, direct-to-implant (DTI) reconstruction has similar low rates of complications and high rates of patient satisfaction compared to traditional 2-stage reconstruction. Conclusions 1-stage prosthetic breast reconstruction may be the procedure of choice in select patients undergoing mastectomy. Advantages include the potential for the entire reconstructive process to be complete in one surgery, the quick return to normal activities, and lack of donor site morbidity. PMID:26005643

  15. The clinical significance of perivalvular pannus in prosthetic mitral valves: Can cardiac CT be helpful?

    PubMed

    Chang, Suyon; Suh, Young Joo; Han, Kyunghwa; Kim, Jin Young; Kim, Young Jin; Chang, Byung-Chul; Choi, Byoung Wook

    2017-12-15

    The clinical significance of pannus in the prosthetic mitral valve (MV) is not well documented. To investigate the clinical significance of pannus on cardiac computed tomography (CT) in patients with a prosthetic MV. A total of 130 patients with previous MV replacement who underwent cardiac CT were retrospectively included in this study. The presence of pannus, paravalvular leak (PVL) around the prosthetic MV and limitation of motion (LOM) of the MV were analyzed using CT. Between patients with MV pannus and those without pannus, CT, echocardiographic, and redo-surgery findings were compared. The diagnostic performance of CT and transesophageal echocardiography (TEE) for the detection of MV pannus was also compared, using surgical findings as a standard reference. MV pannus was observed on cardiac CT in 32.3% of the study population. Patients with MV pannus detected on CT more commonly had LOM (28.2% vs. 15.2%) and less frequently had PVL of the prosthetic MV (16.7% vs. 25%) than patients without MV pannus (P>0.05). Prosthetic valve obstruction (PVO) due prosthetic MV pannus requiring redo-surgery was present in only five patients (11.9%). Cardiac CT detected MV pannus with sensitivity of 65.2% and specificity of 80.9% and showed better diagnostic performance than TEE (P<0.05). Prosthetic MV pannus can frequently be seen on cardiac CT. However, its clinical significance should be assessed with careful consideration, because PVO due to MV pannus is relatively uncommon, and pannus can be seen in patients without any clinical problems. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Development of Subischial Prosthetic Sockets with Vacuum-Assisted Suspension for Highly Active Persons with Transfemoral Amputations

    DTIC Science & Technology

    2014-10-01

    Award Number: W81XWH-10-1-0744 TITLE: Development of Subischial Prosthetic Sockets with Vacuum...REPORT TYPE Annual 3. DATES COVERED 15 Sep 2013 – 14 Sep 2014 4. TITLE AND SUBTITLE Development of Subischial Prosthetic Sockets with Vacuum...to develop a highly flexible sub-ischial prosthetic socket with assisted-vacuum suspension for highly active persons with transfemoral amputation. The

  17. Case study: survey of patient satisfaction with prosthesis quality and design among below-knee prosthetic leg socket users.

    PubMed

    Mohd Hawari, Nurhanisah; Jawaid, Mohammad; Md Tahir, Paridah; Azmeer, Raja Ahmad

    2017-11-01

    The aim of this case study was to explore patient satisfaction with the quality of prosthetic leg sockets intended for persons with lower limb amputations. A qualitative study based on in-depth interviews, preceded by a questionnaire session, was carried out with patients from the Rehabilitation Center and Hospital in Malaysia. Twelve out-patient and in-patient amputees with lower limb amputations, specifically below-knee amputations, were chosen randomly. The analysis of patients' narratives aimed to identify the functional and esthetic characteristics of currently used prosthetic leg sockets and any problems related to them. The obtained results indicated that out of the 12 participants, 41.7% and 25% were satisfied and somewhat satisfied with their current prosthetic sockets. Durability and comfort were rated by the participants as the most important characteristics of prosthetic sockets, with 83.3%. As regards the esthetic appearance of the socket, 66.7% of the respondents considered that the most important feature was the material from which the socket was fabricated. Thus, we conclude that current satisfaction levels with the quality of prosthetic sockets among amputees in Malaysia are suitable, prosthesis being preferred by many amputees. The results can be used to direct future research on cosmesis and functionality of prosthetic socket design. Implications for Rehabilitation Case study will help participants to get cost effective prosthetic leg socket. Develop prosthetic leg socket comfortable as comparative to existing one. Help Malaysian government to make policy to develop local prosthetic leg socket at affordable price.

  18. Prosthetics socket that incorporates an air splint system focusing on dynamic interface pressure

    PubMed Central

    2014-01-01

    Background The interface pressure between the residual limb and prosthetic socket has a significant effect on an amputee’s satisfaction and comfort. This paper presents the design and performance of a new prosthetic socket that uses an air splint system. Methods The air splint prosthetic socket system was implemented by combining the air splint with a pressure sensor that the transhumeral user controls through the use of a microcontroller. The modular construction of the system developed allows the FSR pressure sensors that are placed inside the air splint socket to determine the required size and fitting for the socket used. Fifteen transhumeral amputees participated in the study. Results The subject’s dynamic pressure on the socket that’s applied while wearing the air splint systems was recorded using F-socket transducers and microcontroller analysis. The values collected by the F-socket sensor for the air splint prosthetic socket system were determined accordingly by comparing the dynamic pressure applied using statically socket. The pressure volume of the air splint fluctuated and was recorded at an average of 38 kPa (2.5) to 41 kPa (1.3) over three hours. Conclusion The air splint socket might reduce the pressure within the interface of residual limb. This is particularly important during the daily life activities and may reduce the pain and discomfort at the residual limb in comparison to the static socket. The potential development of an auto-adjusted socket that uses an air splint system as the prosthetic socket will be of interest to researchers involved in rehabilitation engineering, prosthetics and orthotics. PMID:25085005

  19. Increased risk of prosthetic joint infection associated with esophago-gastro-duodenoscopy with biopsy.

    PubMed

    Coelho-Prabhu, Nayantara; Oxentenko, Amy S; Osmon, Douglas R; Baron, Todd H; Hanssen, Arlen D; Wilson, Walter R; Steckelberg, James M; Baddour, Larry M; Harmsen, William S; Mandrekar, Jay; Berbari, Elie F

    2013-02-01

    There are no prospective data regarding the risk of prosthetic joint infection following routine gastrointestinal endoscopic procedures. We wanted to determine the risk of prosthetic hip or knee infection following gastrointestinal endoscopic procedures in patients with joint arthroplasty. We conducted a prospective, single-center, case-control study at a single, tertiary-care referral center. Cases were defined as adult patients hospitalized for prosthetic joint infection of the hip or knee between December 1, 2001 and May 31, 2006. Controls were adult patients with hip or knee arthroplasties but without a diagnosis of joint infection, hospitalized during the same time period at the same orthopedic hospital. The main outcome measure was the odds ratio (OR) of prosthetic joint infection after gastrointestinal endoscopic procedures performed within 2 years before admission. 339 cases and 339 controls were included in the study. Of these, 70 cases (21%) cases and 82 controls (24%) had undergone a gastrointestinal endoscopic procedure in the preceding 2 years. Among gastrointestinal procedures that were assessed, esophago-gastro-duodenoscopy (EGD) with biopsy was associated with an increased risk of prosthetic joint infection (OR = 3, 95% CI: 1.1-7). In a multivariable analysis adjusting for sex, age, joint age, immunosuppression, BMI, presence of wound drain, prior arthroplasty, malignancy, ASA score, and prothrombin time, the OR for infection after EGD with biopsy was 4 (95% CI: 1.5-10). EGD with biopsy was associated with an increased risk of prosthetic joint infection in patients with hip or knee arthroplasties. This association will need to be confirmed in other epidemiological studies and adequately powered prospective clinical trials prior to recommending antibiotic prophylaxis in these patients.

  20. A smartphone photogrammetry method for digitizing prosthetic socket interiors.

    PubMed

    Hernandez, Amaia; Lemaire, Edward

    2017-04-01

    Prosthetic CAD/CAM systems require accurate 3D limb models; however, difficulties arise when working from the person's socket since current 3D scanners have difficulties scanning socket interiors. While dedicated scanners exist, they are expensive and the cost may be prohibitive for a limited number of scans per year. A low-cost and accessible photogrammetry method for socket interior digitization is proposed, using a smartphone camera and cloud-based photogrammetry services. 15 two-dimensional images of the socket's interior are captured using a smartphone camera. A 3D model is generated using cloud-based software. Linear measurements were comparing between sockets and the related 3D models. 3D reconstruction accuracy averaged 2.6 ± 2.0 mm and 0.086 ± 0.078 L, which was less accurate than models obtained by high quality 3D scanners. However, this method would provide a viable 3D digital socket reproduction that is accessible and low-cost, after processing in prosthetic CAD software. Clinical relevance The described method provides a low-cost and accessible means to digitize a socket interior for use in prosthetic CAD/CAM systems, employing a smartphone camera and cloud-based photogrammetry software.

  1. Ergonomic workplace assessment in orthotic and prosthetic workshops.

    PubMed

    Salmani Nodooshan, H; Koohi Booshehri, S; Daneshmandi, H; Choobineh, A R

    2016-10-17

    In Iranian orthotic and prosthetic workshops, the majority of activities are carried out by manpower and the tasks are labor-intensive. In these workshops, ergonomic aspects of working conditions are seldom considered. This study was conducted in orthotic and prosthetic workshops with the objectives of determination of prevalence rate of MSDs among employees and assessment of ergonomics working conditions. In this cross-sectional study, all employees (n = 42; 29 males and 13 females) in 11 active orthotic and prosthetic production centers of Shiraz city participated. Data were collected using Nordic Musculoskeletal disorders Questionnaire (NMQ) and observational technique by an ergonomics checklist for assessment of working conditions. The means (SD) of age and job tenure (years) in the study individuals were 37.26 (10.21) and 12.8 (9.39), respectively. The most prevalent MSD symptoms in the past 12 months were reported in the lower back (42.9%), shoulders (40.5%) and knees (40.5%). Working conditions assessment showed that the main ergonomic problems in the workshops studied originated from awkward working posture, improper workstation design, poorly designed hand tools and incorrect manual material handling. Any interventional program for working conditions improvement should, therefore, focus on these areas.

  2. Smart Prosthetic Hand Technology - Phase 2

    DTIC Science & Technology

    2011-05-01

    identification and estimation, hand motion estimation, intelligent embedded systems and control, robotic hand and biocompatibility and signaling. The...Smart Prosthetics, Bio- Robotics , Intelligent EMG Signal Processing, Embedded Systems and Intelligent Control, Inflammatory Responses of Cells, Toxicity...estimation, intelligent embedded systems and control, robotic hand and biocompatibility and signaling. The developed identification algorithm using a new

  3. Conventional and molecular diagnostic strategies for prosthetic joint infections.

    PubMed

    Esteban, Jaime; Sorlí, Luisa; Alentorn-Geli, Eduard; Puig, Lluís; Horcajada, Juan P

    2014-01-01

    An accurate diagnosis of prosthetic joint infection (PJI) is the mainstay for an optimized clinical management. This review analyzes different diagnostic strategies of PJI, with special emphasis on molecular diagnostic tools and their current and future applications. Until now, the culture of periprosthetic tissues has been considered the gold standard for the diagnosis of PJI. However, sonication of the implant increases the sensitivity of those cultures and is being increasingly adopted by many centers. Molecular diagnostic methods compared with intraoperative tissue culture, especially if combined with sonication, have a higher sensitivity, a faster turnaround time and are not influenced by previous antimicrobial therapy. However, they still lack a system for detection of antimicrobial susceptibility, which is crucial for an optimized and less toxic therapy of PJI. More studies are needed to assess the clinical value of these methods and their cost-effectiveness.

  4. Device to monitor sock use in people using prosthetic limbs: technical report.

    PubMed

    Sanders, Joan E; Murthy, Revathi; Cagle, John C; Allyn, Katheryn J; Phillips, Reid H; Otis, Brian P

    2012-01-01

    A device using radio frequency identification (RFID) technology was developed to continuously monitor sock use in people who use prosthetic limbs. RFID tags were placed on prosthetic socks worn by subjects with transtibial limb loss, and a high-frequency RFID reader and antenna were placed in a portable unit mounted to the outside of the prosthetic socket. Bench testing showed the device to have a maximum read range between 5.6 cm and 12.7 cm, depending on the RFID tag used. Testing in a laboratory setting on three participants with transtibial amputation showed that the device correctly monitored sock presence during sitting, standing, and walking activity when one or two socks were worn but was less reliable when more socks were used. Accurate detection was sensitive to orientation of the tag relative to the reader, presence of carbon fiber in the prosthetic socket, pistoning of the limb in the socket, and overlap among the tags. Use of ultra-high-frequency RFID may overcome these limitations. With improvements, the technology may prove useful to practitioners prescribing volume accommodation strategies for patients by providing information about sock use between clinical visits, including timing and consistency of daily sock-ply changes.

  5. ARM-based visual processing system for prosthetic vision.

    PubMed

    Matteucci, Paul B; Byrnes-Preston, Philip; Chen, Spencer C; Lovell, Nigel H; Suaning, Gregg J

    2011-01-01

    A growing number of prosthetic devices have been shown to provide visual perception to the profoundly blind through electrical neural stimulation. These first-generation devices offer promising outcomes to those affected by degenerative disorders such as retinitis pigmentosa. Although prosthetic approaches vary in their placement of the stimulating array (visual cortex, optic-nerve, epi-retinal surface, sub-retinal surface, supra-choroidal space, etc.), most of the solutions incorporate an externally-worn device to acquire and process video to provide the implant with instructions on how to deliver electrical stimulation to the patient, in order to elicit phosphenized vision. With the significant increase in availability and performance of low power-consumption smart phone and personal device processors, the authors investigated the use of a commercially available ARM (Advanced RISC Machine) device as an externally-worn processing unit for a prosthetic neural stimulator for the retina. A 400 MHz Samsung S3C2440A ARM920T single-board computer was programmed to extract 98 values from a 1.3 Megapixel OV9650 CMOS camera using impulse, regional averaging and Gaussian sampling algorithms. Power consumption and speed of video processing were compared to results obtained to similar reported devices. The results show that by using code optimization, the system is capable of driving a 98 channel implantable device for the restoration of visual percepts to the blind.

  6. Dynamic elasticity measurement for prosthetic socket design.

    PubMed

    Kim, Yujin; Kim, Junghoon; Son, Hyeryon; Choi, Youngjin

    2017-07-01

    The paper proposes a novel apparatus to measure the dynamic elasticity of human limb in order to help the design and fabrication of the personalized prosthetic socket. To take measurements of the dynamic elasticity, the desired force generated as an exponential chirp signal in which the frequency increases and amplitude is maintained according to time progress is applied to human limb and then the skin deformation is recorded, ultimately, to obtain the frequency response of its elasticity. It is referred to as a Dynamic Elasticity Measurement Apparatus (DEMA) in the paper. It has three core components such as linear motor to provide the desired force, loadcell to implement the force feedback control, and potentiometer to record the skin deformation. After measuring the force/deformation and calculating the dynamic elasticity of the limb, it is visualized as 3D color map model of the limb so that the entire dynamic elasticity can be shown at a glance according to the locations and frequencies. For the visualization, the dynamic elasticities measured at specific locations and frequencies are embodied using the color map into 3D limb model acquired by using 3D scanner. To demonstrate the effectiveness, the visualized dynamic elasticities are suggested as outcome of the proposed system, although we do not have any opportunity to apply the proposed system to the amputees. Ultimately, it is expected that the proposed system can be utilized to design and fabricate the personalized prosthetic socket in order for releasing the wearing pain caused by the conventional prosthetic socket.

  7. 38 CFR 17.122 - Payment or reimbursement of the expenses of repairs to prosthetic appliances and similar devices...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... of the expenses of repairs to prosthetic appliances and similar devices furnished without prior... Payment or reimbursement of the expenses of repairs to prosthetic appliances and similar devices furnished without prior authorization. The expenses of repairs to prosthetic appliances, or similar appliances...

  8. Utilization of penile prosthesis and male incontinence prosthetics in Saudi Arabia.

    PubMed

    Alwaal, Amjad; Al-Sayyad, Ahmad J

    2017-01-01

    Erectile dysfunction is a prevalent disease affecting over 50% of men between the ages of 40 and 70 years. Penile prosthesis represents the end of the line treatment when other less invasive therapies fail or are contraindicated. Male stress urinary incontinence can significantly diminish quality of life and lead to embarrassment and social withdrawal. Surgical therapies, such as male urethral slings and artificial urinary sphincters (AUS), are considered effective and safe treatments for male stress incontinence. No data exist on the utilization of penile prosthesis or male incontinence surgical treatment in Saudi Arabia. Generally, urological prosthetic surgery is performed either in private hospitals or in government hospitals. Our aim was to assess the trend of penile prosthesis and male incontinence device utilization in Saudi Arabia. We utilized sales' data of penile prosthetics, male slings, and AUS from the only two companies selling these devices in Saudi Arabia (AMS ® and Coloplast ® ), from January 2013 to December 2016. There were 2599 penile prosthesis implantation procedures done in the study period, with 67% of them performed in private institutions. There was a progressively increased use of penile prosthetics which nearly doubled from 2013 to 2016. The main type of prosthesis utilized was the semirigid type 70% versus 11% of the 2-piece inflatable and 17% of the 3-piece inflatable device. Only 10 slings and 31 AUS were inserted during the same study period. There is an increased utilization of penile prosthetics in Saudi Arabia. The private sector performs the majority of penile prosthesis procedures, and most of them are of the semirigid type. The governmental sector is more likely to perform inflatable penile prosthesis and male incontinence device procedures. Male incontinence prosthetics' use is very limited in Saudi Arabia.

  9. Acinetobacter Prosthetic Joint Infection Treated with Debridement and High-Dose Tigecycline.

    PubMed

    Vila, Andrea; Pagella, Hugo; Amadio, Claudio; Leiva, Alejandro

    2016-12-01

    Prosthesis retention is not recommended for multidrug-resistant Acinetobacter prosthetic joint infection due to its high failure rate. Nevertheless, replacing the prosthesis implies high morbidity and prolonged hospitalization. Although tigecycline is not approved for the treatment of prosthetic joint infection due to multidrug resistant Acinetobacter baumannii, its appropriate use may preclude prosthesis exchange. Since the area under the curve divided by the minimum inhibitory concentration is the best pharmacodynamic predictor of its efficacy, we used tigecycline at high dose, in order to optimize its efficacy and achieve implant retention in 3 patients who refused prosthesis exchange. All patients with prosthetic joint infections treated at our Institution are prospectively registered in a database. Three patients with early prosthetic joint infection of total hip arthroplasty due to multidrug resistant A. baumannii were treated with debridement, antibiotics and implant retention, using a high maintenance dose of tigecycline (100 mg every 12 hours). The cases were retrospectively reviewed. All patients signed informed consent for receiving off-label use of tigecycline. Tigecycline was well tolerated, allowing its administration at high maintenance dose for a median of 40 days (range 30-60). Two patients were then switched to minocycline at standard doses for a median of 3.3 months in order to complete treatment. Currently, none of the patients showed relapse. Increasing the dose of tigecycline could be considered as a means to better attain pharmacodynamic targets in patients with severe or difficult-to-treat infections. Tigecycline at high maintenance dose might be useful when retention of the implant is attempted for treatment for prosthetic joint infections due to multidrug resistant Acinetobacter. Although this approach might be promising, off-label use of tigecycline should be interpreted cautiously until prospective data are available. Tigecycline is

  10. Smart Sensing and Dynamic Fitting for Enhanced Comfort and Performance of Prosthetics

    DTIC Science & Technology

    2017-10-01

    studying microstrip resonators for bio- impedance measurement. For actuation, we have 1) improved and de -bugged the prosthetic interface control ...studying microstrip resonators for bio‐impedance measurement. For actuation, we have 1) improved and de -bugged the prosthetic interface control ...shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number

  11. THE BIOMECHANICAL RESPONSE OF PERSONS WITH TRANSFEMORAL AMPUTATION TO VARIATIONS IN PROSTHETIC KNEE ALIGNMENT DURING LEVEL WALKING

    PubMed Central

    Koehler-McNicholas, Sara R.; Lipschutz, Robert D.; Gard, Steven A.

    2017-01-01

    Prosthetic alignment is an important factor in the overall fit and performance of a lower-limb prosthesis. However, the association between prosthetic alignment and control strategies used by persons with transfemoral amputation to coordinate the movement of a passive prosthetic knee is poorly understood. This study investigated the biomechanical response of persons with transfemoral amputation to systematic perturbations in knee joint alignment during a level walking task. Quantitative gait data were collected for three alignment conditions: bench alignment, 2 cm anterior knee translation (ANT), and 2 cm posterior knee translation (POST). In response to a destabilizing alignment perturbation (ANT), subjects significantly increased their early-stance hip extension moment, confirming that persons with transfemoral amputation rely on a hip extensor strategy to maintain knee joint stability. However, subjects also decreased the rate at which they loaded their prosthesis, decreased their step length, increased their trunk flexion, and maintained their limb in a more vertical posture at the time of opposite toe off. Collectively, these results suggest that persons with transfemoral amputation rely on a combination of strategies to coordinate stance-phase knee flexion. Further, no significant changes were observed in response to the POST condition, suggesting that a bias toward posterior alignment may have fewer implications in terms of stance-phase, knee-joint control. PMID:28355034

  12. Virtual wayfinding using simulated prosthetic vision in gaze-locked viewing.

    PubMed

    Wang, Lin; Yang, Liancheng; Dagnelie, Gislin

    2008-11-01

    To assess virtual maze navigation performance with simulated prosthetic vision in gaze-locked viewing, under the conditions of varying luminance contrast, background noise, and phosphene dropout. Four normally sighted subjects performed virtual maze navigation using simulated prosthetic vision in gaze-locked viewing, under five conditions of luminance contrast, background noise, and phosphene dropout. Navigation performance was measured as the time required to traverse a 10-room maze using a game controller, and the number of errors made during the trip. Navigation performance time (1) became stable after 6 to 10 trials, (2) remained similar on average at luminance contrast of 68% and 16% but had greater variation at 16%, (3) was not significantly affected by background noise, and (4) increased by 40% when 30% of phosphenes were removed. Navigation performance time and number of errors were significantly and positively correlated. Assuming that the simulated gaze-locked viewing conditions are extended to implant wearers, such prosthetic vision can be helpful for wayfinding in simple mobility tasks, though phosphene dropout may interfere with performance.

  13. Implant-Supported Fixed Partial Prostheses With Different Prosthetic Materials: A Three-Dimensional Finite Element Stress Analysis.

    PubMed

    Arinc, Hakan

    2018-06-01

    To evaluate the effects of prosthetic material on the degree of stress to the cortical bone, trabecular bone, framework, and implants using finite element analysis (FEA). A mandibular implant-supported fixed prosthesis was designed. Different prosthetic materials [cobalt-chromium-supported ceramic, zirconia-supported ceramic, and zirconia-reinforced polymethyl methacrylate (ZRPMMA)-supported resin] were used. FEA was used to evaluate stress under different loading conditions. Maximum principal (σmax), minimum principal (σmin), and von Mises (σvM) stress values were obtained. Similar σmax, σmin, and σvM values were observed in the cortical and trabecular bones and in implants under both loading conditions, with the exception of the ZRPMMA model, which showed the highest σmax, σmin, and σvM values in oblique loading. The ZRPMMA model had the lowest σvM value in the framework under both loading conditions. ZRPMMA had the lowest stress values in the framework, with increased stress values in the implants and bone tissue. Framework and veneering materials may influence stress values under different loading conditions.

  14. Factors influencing twins and zygosity.

    PubMed

    Hankins, Gary V D; Saade, George R

    2005-01-01

    Zygosity is influenced by many factors. Monozygotic twins occur spontaneously in approximately 1 in 250 births and are felt to increase twofold with ovulation induction techniques. Monozygotic twinning also increases in proportion to the number of blastocysts transferred during in vitro fertilisation. In contrast, dizygotic twinning appears to be influenced by race, genetic factors, maternal age, fertility enhancing drugs, folic acid supplementation, and maternal nutritional status.

  15. Aerogel Use as a Skin Protective Liner In Space Suits and Prosthetic Limbs Project

    NASA Technical Reports Server (NTRS)

    Roberson, Luke Bennett

    2014-01-01

    Existing materials for prosthetic liners tend to be thick and airtight, causing perspiration to accumulate inside the liner and potentially causing infection and injury. The purpose of this project was to examine the suitability of aerogel for prosthetic liner applications for use in space suits and orthopedics. Three tests were performed on several types of aerogel to assess the properties of each material, and our initial findings demonstrated that these materrials would be excellent candidates for liner applications for prosthetics and space suits. The project is currently on hold until additional funding is obtained for application testing at the VH Hospitals in Tampa

  16. Responsiveness of outcome measures for upper limb prosthetic rehabilitation.

    PubMed

    Resnik, Linda; Borgia, Matthew

    2016-02-01

    There is limited research on responsiveness of prosthetic rehabilitation outcome measures. To examine responsiveness of the Box and Block test, Jebsen-Taylor Hand Function tests, Upper Extremity Functional Scale, University of New Brunswick skill and spontaneity tests, Activity Measure for Upper Limb Amputation, and the Patient-Specific Functional Scale. This was a quasi-experimental study with repeated measurements in a convenience sample of upper limb amputees. Measures were collected before, during, and after training with the DEKA Arm. Largest effect sizes were observed for Patient-Specific Functional Scale (effect size: 1.59, confidence interval: 1.00, 2.14), Activity Measure for Upper Limb Amputation (effect size: 1.33, confidence interval: 0.73, 1.90), and University of New Brunswick skill test (effect size: 1.18, confidence interval: 0.61, 1.73). Other measures that were responsive to change were Box and Block test, Jebsen-Taylor Hand Function light and heavy can tests, and University of New Brunswick spontaneity test. Responsiveness and pattern of responsiveness varied by prosthetic level. The Box and Block test, Jebsen-Taylor Hand Function light and heavy can tests, University of New Brunswick skill and spontaneity tests, Activities Measure for Upper Limb Amputation, and the Patient-Specific Functional Scale were responsive to change during prosthetic training. These findings have implications for choice of measures for research and practice and inform clinicians about the amount of training necessary to maximize outcomes with the DEKA Arm. Findings on responsiveness of outcome measures have implications for the choice of measures for clinical trials and practice. Findings regarding the responsiveness to change over the course of training can inform clinicians about the amount of training that may be necessary to maximize specific outcomes with the DEKA Arm. © The International Society for Prosthetics and Orthotics 2014.

  17. Self-cleaning skin-like prosthetic polymer surfaces

    DOEpatents

    Simpson, John T [Clinton, TN; Ivanov, Ilia N [Knoxville, TN; Shibata, Jason [Manhattan Beach, CA

    2012-03-27

    An external covering and method of making an external covering for hiding the internal endoskeleton of a mechanical (e.g., prosthetic) device that exhibits skin-like qualities is provided. The external covering generally comprises an internal bulk layer in contact with the endoskeleton of the prosthetic device and an external skin layer disposed about the internal bulk layer. The external skin layer is comprised of a polymer composite with carbon nanotubes embedded therein. The outer surface of the skin layer has multiple cone-shaped projections that provide the external skin layer with superhydrophobicity. The carbon nanotubes are preferably vertically aligned between the inner surface and outer surface of the external skin layer in order to provide the skin layer with the ability to transmit heat. Superhydrophobic powders may optionally be used as part of the polymer composite or applied as a coating to the surface of the skin layer to enhance superhydrophobicity.

  18. Is the Prosthetic Homologue Necessary for Embodiment?

    PubMed Central

    Dornfeld, Chelsea; Swanston, Michelle; Cassella, Joseph; Beasley, Casey; Green, Jacob; Moshayev, Yonatan; Wininger, Michael

    2016-01-01

    Embodiment is the process by which patients with limb loss come to accept their peripheral device as a natural extension of self. However, there is little guidance as to how exacting the prosthesis must be in order for embodiment to take place: is it necessary for the prosthetic hand to look just like the absent hand? Here, we describe a protocol for testing whether an individual would select a hand that looks like their own from among a selection of five hands, and whether the hand selection (regardless of homology) is consistent across multiple exposures to the same (but reordered) set of candidate hands. Pilot results using healthy volunteers reveals that hand selection is only modestly consistent, and that selection of the prosthetic homologue is atypical (61 of 192 total exposures). Our protocol can be executed in minutes, and makes use of readily available equipment and softwares. We present both a face-to-face and a virtual protocol, for maximum flexibility of implementation. PMID:28066228

  19. Increasing prosthetic foot energy return affects whole-body mechanics during walking on level ground and slopes.

    PubMed

    Childers, W Lee; Takahashi, Kota Z

    2018-03-29

    Prosthetic feet are designed to store energy during early stance and then release a portion of that energy during late stance. The usefulness of providing more energy return depends on whether or not that energy transfers up the lower limb to aid in whole body propulsion. This research examined how increasing prosthetic foot energy return affected walking mechanics across various slopes. Five people with a uni-lateral transtibial amputation walked on an instrumented treadmill at 1.1 m/s for three conditions (level ground, +7.5°, -7.5°) while wearing a prosthetic foot with a novel linkage system and a traditional energy storage and return foot. The novel foot demonstrated greater range of motion (p = 0.0012), and returned more energy (p = 0.023) compared to the traditional foot. The increased energy correlated with an increase in center of mass (CoM) energy change during propulsion from the prosthetic limb (p = 0.012), and the increased prosthetic limb propulsion correlated to a decrease in CoM energy change (i.e., collision) on the sound limb (p < 0.001). These data indicate that this novel foot was able to return more energy than a traditional prosthetic foot and that this additional energy was used to increase whole body propulsion.

  20. Development of reversible vas deferens occlusive device: IV. Rigid prosthetic devices.

    PubMed

    Drueschke, E E; Zaneveld, L J; Burns, M; Rodzen, R; Wingfield, J R; Maness, J H

    1975-01-01

    Different types of rigid, reversible, vas deferens occlusive devices were developed and evaluated in 14 unilaterally vasectomized dogs. All prosthetic devices had molded silicone rubber bodies, and rigid inflow and outflow tubes. Various techniques for the removal of the vas luminal epithelium, and for the preparation of porous ceramic and etched stainless steel surfaces to encourage tissue ingrowth into the prosthetic device end tubues were attempted. The devices differed in their methods of achieving occlusion. One device used a "rotary stem valve" which had a C-section rotating mechanism; the others used the "shuttle stem valve" which possessed an occlusive element that moved transverse to the axis of flow in the device, thus occluding the device when the stem was depressed. The rotarystem valve was implanted by means of a longitudinal incision. The remaining 13 shuttle stem devices were placed in the vas using either a longitudinal or a transverse implantation. Inno case was sperm transport through the prosthetic devices obtained for more than a few ejaculations.

  1. Immediate effects of a new microprocessor-controlled prosthetic knee joint: a comparative biomechanical evaluation.

    PubMed

    Bellmann, Malte; Schmalz, Thomas; Ludwigs, Eva; Blumentritt, Siegmar

    2012-03-01

    To investigate the immediate biomechanical effects after transition to a new microprocessor-controlled prosthetic knee joint. Intervention cross-over study with repeated measures. Only prosthetic knee joints were changed. Motion analysis laboratory. Men (N=11; mean age ± SD, 36.7±10.2y; Medicare functional classification level, 3-4) with unilateral transfemoral amputation. Two microprocessor-controlled prosthetic knee joints: C-Leg and a new prosthetic knee joint, Genium. Static prosthetic alignment, time-distance parameters, kinematic and kinetic parameters, and center of pressure. After a half-day training and an additional half-day accommodation, improved biomechanical outcomes were demonstrated by the Genium: lower ground reaction forces at weight acceptance during level walking at various velocities, increased swing phase flexion angles during walking on a ramp, and level walking with small steps. Maximum knee flexion angle during swing phase at various velocities was nearly equal for Genium. Step-over-step stair ascent with the Genium knee was more physiologic as demonstrated by a more equal load distribution between the prosthetic and contralateral sides and a more natural gait pattern. When descending stairs and ramps, knee flexion moments with the Genium tended to increase. During quiet stance on a decline, subjects using Genium accepted higher loading of the prosthetic side knee joint, thus reducing same side hip joint loading as well as postural sway. In comparision to the C-Leg, the Genium demonstrated immediate biomechanical advantages during various daily ambulatory activities, which may lead to an increase in range and diversity of activity of people with above-knee amputations. Results showed that use of the Genium facilitated more natural gait biomechanics and load distribution throughout the affected and sound musculoskeletal structure. This was observed during quiet stance on a decline, walking on level ground, and walking up and down ramps and

  2. Prosthetic joint infection caused by Pasteurella multocida: a case series and review of literature.

    PubMed

    Honnorat, Estelle; Seng, Piseth; Savini, Hélène; Pinelli, Pierre-Olivier; Simon, Fabrice; Stein, Andreas

    2016-08-20

    Pasteurella multocida is a well-recognized zoonotic agent following dog or cat bites or scratches. Nevertheless, prosthetic joint infection caused by P. multocida are rarely reported. We report here a series of six cases of prosthetic joint infection caused by P. multocida managed at a referral centre for the treatment of bone and joint infection in southern France. We also reviewed the 26 cases reported in literature. The mean age of our cases was 74 years [±8.2, range 63-85]. In majority of our cases (5 cases) were associated with knee prostheses and one case with a hip prosthesis. Most of cases occurred after cat or dog scratches or licks or contact. Diagnoses of prosthetic joint infection caused by P. multocida were made by positive cultures of surgical biopsies or needle aspiration. Mean time delay between prosthetic joint implantation and infection onset was 7.6 years (±5.12 years, range 2-17). Local inflammation, which occurred in all six cases, was the most frequent clinical symptom, followed by pain in five cases, fever and swollen joints in four cases, and a fistula with purulent discharge inside the wound in two cases. The mean time of antibiotic therapy was 8 months. Surgical treatment with prosthesis removal was performed in three cases. Six of our cases were in remission without apparent relapse at 3 years after end of treatment. Prosthetic joint infections caused by P. multocida usually occur after animal scratches or bites, but can occasionally occur after a short animal lick. These infections are usually resulting from a contiguous infection and localized in the knee. An early antibiotic therapy after surgical debridement could avoid prosthetic withdrawal, notably in elderly patients. Patients with prosthetic joints should be warned that animals are potential sources of serious infection and urgent medical advice should be sought if they are bitten or scratched.

  3. Facilitating Children's Adjustment to Orthotic and Prosthetic Appliances.

    ERIC Educational Resources Information Center

    Fredrick, Jeff; Fletcher, Donna

    1985-01-01

    Guidelines are offered to help teachers understand the nature and use of orthotic and prosthetic appliances for disabled students. Classroom behavior observations are noted so that teachers can help monitor the child's adjustment to the appliance. (CL)

  4. Proceedings, 1972 Carahan Conference on Electronic Prosthetics.

    ERIC Educational Resources Information Center

    Jackson, John S., Ed.; DeVore, R. William, Ed.

    Presented are 28 papers given at a 1972 conference on electronic prosthetics for the handicapped. Among the papers are the following titles: "Therapy for Cerebral Palsy Employing Artifician Sense Organs for Alternatives to Proprioceptive Feedback"; "Excessive Neuromuscular Time Delay as a Possible Cause of Poor Hand-Eye Coordination and…

  5. Selected applications for current polymers in prosthetic dentistry - state of the art.

    PubMed

    Kawala, Maciej; Smardz, Joanna; Adamczyk, Lukasz; Grychowska, Natalia; Wieckiewicz, Mieszko

    2018-05-10

    Polymers are widely applied in medicine, including dentistry, i.e. in prosthodontics. The following paper is aimed at demonstrating the applications of selected modern polymers in prosthetic dentistry based on the reported literature. The study was conducted using the PubMed, SCOPUS and CINAHL databases in relation to documents published during 1999-2017. The following keywords were used: polymers with: prosthetic dentistry, impression materials, denture base materials, bite registration materials, denture soft liners, occlusal splint materials and 3D printing. Original papers and reviews which were significant from the modern clinical viewpoint and practical validity in relation to the possibility of using polymeric materials in prosthetic dentistry, were presented. Denture base materials were most commonly modified polymers. Modifications mainly concerned antimicrobial properties and reinforcement of the material structure by introducing additional fibers. Antimicrobial modifications were also common in case of relining materials. Polymeric materials have widely been used in prosthetic dentistry. Modifications of their composition allow achieving new, beneficial properties that affect quality of patients' life. Progress in science allows for a more methodologically-advanced research on the synthesis of new polymeric materials and incorporation of new substances into already known polymeric materials, that will require systematization and appropriate classification. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  6. Design and characterization of a biologically inspired quasi-passive prosthetic ankle-foot.

    PubMed

    Mooney, Luke M; Lai, Cara H; Rouse, Elliott J

    2014-01-01

    By design, commonly worn energy storage and release (ESR) prosthetic feet cannot provide biologically realistic ankle joint torque and angle profiles during walking. Additionally, their anthropomorphic, cantilever architecture causes their mechanical stiffness to decrease throughout the stance phase of walking, opposing the known trend of the biological ankle. In this study, the design of a quasi-passive pneumatic ankle-foot prosthesis is detailed that is able to replicate the biological ankle's torque and angle profiles during walking. The prosthetic ankle is comprised of a pneumatic piston, bending spring and solenoid valve. The mechanical properties of the pneumatic ankle prosthesis are characterized using a materials testing machine and the properties are compared to those from a common, passive ESR prosthetic foot. The characterization spanned a range of ankle equilibrium pressures and testing locations beneath the foot, analogous to the location of center of pressure within the stance phase of walking. The pneumatic ankle prosthesis was shown to provide biologically appropriate trends and magnitudes of torque, angle and stiffness behavior, when compared to the passive ESR prosthetic foot. Future work will focus on the development of a control system for the quasi-passive device and clinical testing of the pneumatic ankle to demonstrate efficacy.

  7. Novel implant for peri-prosthetic proximal tibia fractures.

    PubMed

    Tran, Ton; Chen, Bernard K; Wu, Xinhua; Pun, Chung Lun

    2018-03-01

    Repair of peri-prosthetic proximal tibia fractures is very challenging in patients with a total knee replacement or arthroplasty. The tibial component of the knee implant severely restricts the fixation points of the tibial implant to repair peri-prosthetic fractures. A novel implant has been designed with an extended flange over the anterior of tibial condyle to provide additional points of fixation, overcoming limitations of existing generic locking plates used for proximal tibia fractures. Furthermore, the screws fixed through the extended flange provide additional support to prevent the problem of subsidence of tibial component of knee implant. The design methodology involved extraction of bone data from CT scans into a flexible CAD format, implant design and structural evaluation and optimisation using FEM as well as prototype development and manufacture by selective laser melting 3D printing technology with Ti6Al4 V powder. A prototype tibia implant was developed based on a patient-specific bone structure, which was regenerated from the CT images of patient's tibia. The design is described in detail and being applied to fit up to 80% of patients, for both left and right sides based on the average dimensions and shape of the bone structure from a wide range of CT images. A novel tibial implant has been developed to repair peri-prosthetic proximal tibia fractures which overcomes significant constraints from the tibial component of existing knee implant. Copyright © 2018 Elsevier Ltd. All rights reserved.

  8. Definition, clinical profile, microbiological spectrum, and prognostic factors of early-onset prosthetic valve endocarditis.

    PubMed

    López, Javier; Revilla, Ana; Vilacosta, Isidre; Villacorta, Eduardo; González-Juanatey, Carlos; Gómez, Itziar; Rollán, María Jesús; San Román, José Alberto

    2007-03-01

    There is no agreement in the best cutoff time to distinguish between early- and late- onset prosthetic valve endocarditis (PVE). Our objectives are to define early-onset PVE according to the microbiological spectrum and to analyse the profile and short-term prognosis of this entity. The microbiological profile of 172 non-drug users, who were patients with PVE, were compared according to the time elapsed from surgery among 640 endocarditis diagnosed between 1996 and 2004. There were no differences in the microbiological profile of patients with PVE occurred within 2 months of valve replacement and those accounting between 2 and 12 months. The proportion of coagulase-negative Staphylococci (CNS) was higher during the first year post-intervention (37 vs. 18%, P = 0.005) and Streptococci viridans were more common after 1 year (18 vs. 1%, P = 0.001). The percentage of methicilin-resistant CNS strains was higher before 1 year (77 vs. 30%, P = 0.004). Early-onset PVE represented 38% of all episodes of PVE, CNS being the most frequent isolated microorganisms (37%), most of them methicilin resistant (77%). In-hospital mortality of patients who needed urgent surgery was 46% and elective surgery 25%. Overall, in-hospital mortality was 38% and no differences were seen between surgical and medical groups (32 vs. 45%, P = 0.30). Periannular complications were associated with higher in-hospital mortality (60 vs. 27%, P = 0.007). According to the microbiological profile, the most appropriate cutoff time to distinguish between early- and late-onset PVE was 1 year. Methicilin-resistant CNS are the most frequent pathogens and periannular complications, the only risk factor for in-hospital mortality.

  9. Recurrent prosthetic valve endocarditis caused by Aspergillus delacroxii (formerly Aspergillus nidulans var. echinulatus)

    PubMed Central

    Uhrin, Gábor Balázs; Jensen, Rasmus Hare; Korup, Eva; Grønlund, Jens; Hjort, Ulla; Moser, Claus; Arendrup, Maiken Cavling; Schønheyder, Henrik Carl

    2015-01-01

    We report Aspergillus delacroxii (formerly Aspergillus nidulans var. echinulatus) causing recurrent prosthetic valve endocarditis. The fungus was the sole agent detected during replacement of a mechanical aortic valve conduit due to abscess formation. Despite extensive surgery and anti-fungal treatment, the patient had a cerebral hemorrhage 4 months post-surgery prompting a diagnosis of recurrent prosthetic valve endocarditis and fungemia. PMID:26909244

  10. Nitinol for Prosthetic and Orthotic Applications

    NASA Astrophysics Data System (ADS)

    Henderson, Emma; Buis, Arjan

    2011-07-01

    As global populations age, conditions such as stroke and diabetes require individuals to use rehabilitation technology for many years to come due to chronic musculoskeletal, sensory, and other physical impairments. One in four males currently aged 45 will experience a stroke within 40 years and will often require access to prolonged rehabilitation. In addition, worldwide, one individual loses a limb every 30 s due to the complications of diabetes. As a result, innovative ideas are required to devise more effective prosthetic and orthotic devices to enhance quality of life. While Nitinol has already found much favor within the biomedical industry, one area, which has not yet exploited its unique properties, is in the field of physical rehabilitation, ranging from prosthetic and orthotic devices to assistive technology such as wheelchairs. Improved intervention capabilities based on materials such as Nitinol have the potential to vastly improve patients' quality of life and in the case of orthoses, may even reduce the severity of the condition over time. It is hoped that this study will spark discussion and interest for the materials community in a field which has yet to be fully exploited.

  11. Does a microprocessor-controlled prosthetic knee affect stair ascent strategies in persons with transfemoral amputation?

    PubMed

    Aldridge Whitehead, Jennifer M; Wolf, Erik J; Scoville, Charles R; Wilken, Jason M

    2014-10-01

    Stair ascent can be difficult for individuals with transfemoral amputation because of the loss of knee function. Most individuals with transfemoral amputation use either a step-to-step (nonreciprocal, advancing one stair at a time) or skip-step strategy (nonreciprocal, advancing two stairs at a time), rather than a step-over-step (reciprocal) strategy, because step-to-step and skip-step allow the leading intact limb to do the majority of work. A new microprocessor-controlled knee (Ottobock X2(®)) uses flexion/extension resistance to allow step-over-step stair ascent. We compared self-selected stair ascent strategies between conventional and X2(®) prosthetic knees, examined between-limb differences, and differentiated stair ascent mechanics between X2(®) users and individuals without amputation. We also determined which factors are associated with differences in knee position during initial contact and swing within X2(®) users. Fourteen individuals with transfemoral amputation participated in stair ascent sessions while using conventional and X2(®) knees. Ten individuals without amputation also completed a stair ascent session. Lower-extremity stair ascent joint angles, moment, and powers and ground reaction forces were calculated using inverse dynamics during self-selected strategy and cadence and controlled cadence using a step-over-step strategy. One individual with amputation self-selected a step-over-step strategy while using a conventional knee, while 10 individuals self-selected a step-over-step strategy while using X2(®) knees. Individuals with amputation used greater prosthetic knee flexion during initial contact (32.5°, p = 0.003) and swing (68.2°, p = 0.001) with higher intersubject variability while using X2(®) knees compared to conventional knees (initial contact: 1.6°, swing: 6.2°). The increased prosthetic knee flexion while using X2(®) knees normalized knee kinematics to individuals without amputation during swing (88.4°, p = 0.179) but

  12. [Prosthetic joint infection: a prospective study in five Catalonian hospitals].

    PubMed

    García-Pont, Javier; Blanch-Falp, Jesús; Coll-Colell, Rosa; Rosell-Abaurrea, Francesc; Tapiz-Reula, Alfons; Dorca-Badía, Ester; Masabeu-Urrutia, Angels; Martín-Urda, Anabel; Barrufet-Barque, Pilar; Force-Sanmartín, Lluis

    2006-03-01

    Prosthetic joint infections are a cause of increasing morbidity and medical expenditure. To determine the incidence and the clinical and the epidemiological characteristics of knee and hip prosthetic infections (PI) in patients undergoing elective surgery in five Catalonian hospitals. To determine the predictive factors of PI. A total of 425 patients operated on between 8 January and 8 July 2001 were prospectively followed for a period of two years. The cumulative incidence, incidence rate and effect measures were determined. Logistic regression was used to identify variables associated with PI. Average age was 71 years and 63.1% were women. Antibiotic prophylaxis with cefazolin was given to 44.7% of the patients, with a mean duration of two days. Prophylaxis was administered during anesthesia induction in 75.6% of the patients. Among the total, 63.4% of the patients were ASA 2. Microbiological confirmation was obtained in all the infected patients; Staphylococcus epidermidis was found in 58%. Fourteen PI were diagnosed, 71% during the first 3 months, with a cumulative incidence of 3.29% and a 3-month incidence rate of 63 patients/10,000 patients/month. Diabetes mellitus was the only variable related to PI in the multivariate analysis: 3.18, 95% CI (1.1-9.9). The cumulative incidence of PI was slightly higher than that seen in other studies. Variations were observed in the antibiotic used for prophylaxis, and the place where it was administered. PI occurred 3.18 times more frequently in diabetic patients.

  13. A patterned microtexture to reduce friction and increase longevity of prosthetic hip joints

    PubMed Central

    Chyr, Anthony; Qiu, Mingfeng; Speltz, Jared; Jacobsen, Ronald L.; Sanders, Anthony P.; Raeymaekers, Bart

    2014-01-01

    More than 285,000 total hip replacement surgeries are performed in the US each year. Most prosthetic hip joints consist of a cobalt-chromium (CoCr) femoral head that articulates with a polyethylene acetabular component, lubricated with synovial fluid. The statistical survivorship of these metal-on-polyethylene prosthetic hip joints declines significantly after 10 to 15 years of use, primarily as a result of polyethylene wear and wear debris incited disease. The current engineering paradigm to increase the longevity of prosthetic hip joints is to improve the mechanical properties of the polyethylene component, and to manufacture ultra-smooth articulating surfaces. In contrast, we show that adding a patterned microtexture to the ultra-smooth CoCr femoral head reduces friction when articulating with the polyethylene acetabular liner. The microtexture increases the load-carrying capacity and the thickness of the joint lubricant film, which reduces contact between the articulating surfaces. As a result, friction and wear is reduced. We have used a lubrication model to design the geometry of the patterned microtexture, and experimentally demonstrate reduced friction for the microtextured compared to conventional smooth surrogate prosthetic hip joints. PMID:25013240

  14. Nuclear Medicine in Diagnosis of Prosthetic Valve Endocarditis: An Update

    PubMed Central

    Musso, Maria; Petrosillo, Nicola

    2015-01-01

    Over the past decades cardiovascular disease management has been substantially improved by the increasing introduction of medical devices as prosthetic valves. The yearly rate of infective endocarditis (IE) in patient with a prosthetic valve is approximately 3 cases per 1,000 patients. The fatality rate of prosthetic valve endocarditis (PVE) remains stable over the years, in part due to the aging of the population. The diagnostic value of echocardiography in diagnosis is operator-dependent and its sensitivity can decrease in presence of intracardiac devices and valvular prosthesis. The modified Duke criteria are considered the gold standard for diagnosing IE; their sensibility is 80%, but in clinical practice their diagnostic accuracy in PVE is lower, resulting inconclusively in nearly 30% of cases. In the last years, these new imaging modalities have gained an increasing attention because they make it possible to diagnose an IE earlier than the structural alterations occurring. Several studies have been conducted in order to assess the diagnostic accuracy of various nuclear medicine techniques in diagnosis of PVE. We performed a review of the literature to assess the available evidence on the role of nuclear medicine techniques in the diagnosis of PVE. PMID:25695043

  15. The effects of a controlled energy storage and return prototype prosthetic foot on transtibial amputee ambulation

    PubMed Central

    Segal, Ava D.; Zelik, Karl E.; Klute, Glenn K.; Morgenroth, David C.; Hahn, Michael E.; Orendurff, Michael S.; Adamczyk, Peter G.; Collins, Steven H.; Kuo, Arthur D.; Czerniecki, Joseph M.

    2015-01-01

    The lack of functional ankle musculature in lower limb amputees contributes to the reduced prosthetic ankle push-off, compensations at other joints and more energetically costly gait commonly observed in comparison to non-amputees. A variety of energy storing and return prosthetic feet have been developed to address these issues but have not been shown to sufficiently improve amputee biomechanics and energetic cost, perhaps because the timing and magnitude of energy return is not controlled. The goal of this study was to examine how a prototype microprocessor-controlled prosthetic foot designed to store some of the energy during loading and return it during push-off affects amputee gait. Unilateral transtibial amputees wore the Controlled Energy Storage and Return prosthetic foot (CESR), a conventional foot (CONV), and their previously prescribed foot (PRES) in random order. Three-dimensional gait analysis and net oxygen consumption were collected as participants walked at constant speed. The CESR foot demonstrated increased energy storage during early stance, increased prosthetic foot peak push-off power and work, increased prosthetic limb center of mass (COM) push-off work and decreased intact limb COM collision work compared to CONV and PRES. The biological contribution of the positive COM work for CESR was reduced compared to CONV and PRES. However, the net metabolic cost for CESR did not change compared to CONV and increased compared to PRES, which may partially reflect the greater weight, lack of individualized size and stiffness and relatively less familiarity for CESR and CONV. Controlled energy storage and return enhanced prosthetic push-off, but requires further design modifications to improve amputee walking economy. PMID:22100728

  16. The effects of a controlled energy storage and return prototype prosthetic foot on transtibial amputee ambulation.

    PubMed

    Segal, Ava D; Zelik, Karl E; Klute, Glenn K; Morgenroth, David C; Hahn, Michael E; Orendurff, Michael S; Adamczyk, Peter G; Collins, Steven H; Kuo, Arthur D; Czerniecki, Joseph M

    2012-08-01

    The lack of functional ankle musculature in lower limb amputees contributes to the reduced prosthetic ankle push-off, compensations at other joints and more energetically costly gait commonly observed in comparison to non-amputees. A variety of energy storing and return prosthetic feet have been developed to address these issues but have not been shown to sufficiently improve amputee biomechanics and energetic cost, perhaps because the timing and magnitude of energy return is not controlled. The goal of this study was to examine how a prototype microprocessor-controlled prosthetic foot designed to store some of the energy during loading and return it during push-off affects amputee gait. Unilateral transtibial amputees wore the Controlled Energy Storage and Return prosthetic foot (CESR), a conventional foot (CONV), and their previously prescribed foot (PRES) in random order. Three-dimensional gait analysis and net oxygen consumption were collected as participants walked at constant speed. The CESR foot demonstrated increased energy storage during early stance, increased prosthetic foot peak push-off power and work, increased prosthetic limb center of mass (COM) push-off work and decreased intact limb COM collision work compared to CONV and PRES. The biological contribution of the positive COM work for CESR was reduced compared to CONV and PRES. However, the net metabolic cost for CESR did not change compared to CONV and increased compared to PRES, which may partially reflect the greater weight, lack of individualized size and stiffness and relatively less familiarity for CESR and CONV. Controlled energy storage and return enhanced prosthetic push-off, but requires further design modifications to improve amputee walking economy. Published by Elsevier B.V.

  17. Control of Prosthetic Hands via the Peripheral Nervous System

    PubMed Central

    Ciancio, Anna Lisa; Cordella, Francesca; Barone, Roberto; Romeo, Rocco Antonio; Bellingegni, Alberto Dellacasa; Sacchetti, Rinaldo; Davalli, Angelo; Di Pino, Giovanni; Ranieri, Federico; Di Lazzaro, Vincenzo; Guglielmelli, Eugenio; Zollo, Loredana

    2016-01-01

    This paper intends to provide a critical review of the literature on the technological issues on control and sensorization of hand prostheses interfacing with the Peripheral Nervous System (i.e., PNS), and their experimental validation on amputees. The study opens with an in-depth analysis of control solutions and sensorization features of research and commercially available prosthetic hands. Pros and cons of adopted technologies, signal processing techniques and motion control solutions are investigated. Special emphasis is then dedicated to the recent studies on the restoration of tactile perception in amputees through neural interfaces. The paper finally proposes a number of suggestions for designing the prosthetic system able to re-establish a bidirectional communication with the PNS and foster the prosthesis natural control. PMID:27092041

  18. First-in-man demonstration of a fully implanted myoelectric sensors system to control an advanced electromechanical prosthetic hand.

    PubMed

    Pasquina, Paul F; Evangelista, Melissa; Carvalho, A J; Lockhart, Joseph; Griffin, Sarah; Nanos, George; McKay, Patricia; Hansen, Morten; Ipsen, Derek; Vandersea, James; Butkus, Josef; Miller, Matthew; Murphy, Ian; Hankin, David

    2015-04-15

    Advanced motorized prosthetic devices are currently controlled by EMG signals generated by residual muscles and recorded by surface electrodes on the skin. These surface recordings are often inconsistent and unreliable, leading to high prosthetic abandonment rates for individuals with upper limb amputation. Surface electrodes are limited because of poor skin contact, socket rotation, residual limb sweating, and their ability to only record signals from superficial muscles, whose function frequently does not relate to the intended prosthetic function. More sophisticated prosthetic devices require a stable and reliable interface between the user and robotic hand to improve upper limb prosthetic function. Implantable Myoelectric Sensors (IMES(®)) are small electrodes intended to detect and wirelessly transmit EMG signals to an electromechanical prosthetic hand via an electro-magnetic coil built into the prosthetic socket. This system is designed to simultaneously capture EMG signals from multiple residual limb muscles, allowing the natural control of multiple degrees of freedom simultaneously. We report the status of the first FDA-approved clinical trial of the IMES(®) System. This study is currently in progress, limiting reporting to only preliminary results. Our first subject has reported the ability to accomplish a greater variety and complexity of tasks in his everyday life compared to what could be achieved with his previous myoelectric prosthesis. The interim results of this study indicate the feasibility of utilizing IMES(®) technology to reliably sense and wirelessly transmit EMG signals from residual muscles to intuitively control a three degree-of-freedom prosthetic arm. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Actinobaculum schaalii, a new cause of knee prosthetic joint infection in elderly.

    PubMed

    Jacquier, H; Benmansour, H; Zadegan, F; Hannouche, D; Micaelo, M; Mongiat-Artus, P; Salomon, E; Cambau, E; Berçot, B

    2016-08-01

    Actinobaculum schaalii is an emerging pathogen particularly involved in urinary tract infection of elderly people and/or patient with urological risk factors of urinary tract infection. This microorganism is a difficult-to-diagnose pathogen and is rarely involved in systemic or deep infections. Here, we report the first case of prosthetic joint infection due to A. schaalii in an 84-year-old man with a benign prostatic hyperplasia associated with chronic retention of urine. This case underlines the importance to optimize the diagnosis of emerging uropathogens as A. schaalii, to prevent systemic infections, particularly in patients with orthopaedic implants.

  20. Systematic review of effects of current transtibial prosthetic socket designs--Part 2: Quantitative outcomes.

    PubMed

    Safari, Mohammad Reza; Meier, Margrit Regula

    2015-01-01

    This review is an attempt to untangle the complexity of transtibial prosthetic socket fit and perhaps find some indication of whether a particular prosthetic socket type might be best for a given situation. In addition, we identified knowledge gaps, thus providing direction for possible future research. We followed the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines, using medical subject headings and standard key words to search for articles in relevant databases. No restrictions were made on study design and type of outcome measure used. From the obtained search results (n = 1,863), 35 articles were included. The relevant data were entered into a predefined data form that included the Downs and Black risk of bias assessment checklist. This article presents the results from the systematic review of the quantitative outcomes (n = 27 articles). Trends indicate that vacuum-assisted suction sockets improve gait symmetry, volume control, and residual limb health more than other socket designs. Hydrostatic sockets seem to create less inconsistent socket fittings, reducing a problem that greatly influences outcome measures. Knowledge gaps exist in the understanding of clinically meaningful changes in socket fit and its effect on biomechanical outcomes. Further, safe and comfortable pressure thresholds under various conditions should be determined through a systematic approach.

  1. Prosthetic Smart Socket Technology to Improve Patient Interaction, Usability, Comfort, Fit and Function

    DTIC Science & Technology

    2017-10-01

    AWARD NUMBER: W81XWH-16-1-0785 TITLE: Prosthetic Smart Socket Technology to Improve Patient Interaction, Usability, Comfort, Fit and Function...2016 - 29 Sep 2017 4. TITLE AND SUBTITLE Prosthetic Smart Socket Technology to Improve Patient Interaction, Usability, Comfort, Fit and Function 5a...discomfort. 2. KEYWORDS: Provide a brief list of keywords (limit to 20 words). Prosthesis, prosthesis fit, technology , skin problems, amputee

  2. Power feasibility of implantable digital spike sorting circuits for neural prosthetic systems.

    PubMed

    Zumsteg, Zachary S; Kemere, Caleb; O'Driscoll, Stephen; Santhanam, Gopal; Ahmed, Rizwan E; Shenoy, Krishna V; Meng, Teresa H

    2005-09-01

    A new class of neural prosthetic systems aims to assist disabled patients by translating cortical neural activity into control signals for prosthetic devices. Based on the success of proof-of-concept systems in the laboratory, there is now considerable interest in increasing system performance and creating implantable electronics for use in clinical systems. A critical question that impacts system performance and the overall architecture of these systems is whether it is possible to identify the neural source of each action potential (spike sorting) in real-time and with low power. Low power is essential both for power supply considerations and heat dissipation in the brain. In this paper we report that state-of-the-art spike sorting algorithms are not only feasible using modern complementary metal oxide semiconductor very large scale integration processes, but may represent the best option for extracting large amounts of data in implantable neural prosthetic interfaces.

  3. The biomechanical response of persons with transfemoral amputation to variations in prosthetic knee alignment during level walking.

    PubMed

    Koehler-McNicholas, Sara R; Lipschutz, Robert D; Gard, Steven A

    2016-01-01

    Prosthetic alignment is an important factor in the overall fit and performance of a lower-limb prosthesis. However, the association between prosthetic alignment and control strategies used by persons with transfemoral amputation to coordinate the movement of a passive prosthetic knee is poorly understood. This study investigated the biomechanical response of persons with transfemoral amputation to systematic perturbations in knee joint alignment during a level walking task. Quantitative gait data were collected for three alignment conditions: bench alignment, 2 cm anterior knee translation (ANT), and 2 cm posterior knee translation (POST). In response to a destabilizing alignment perturbation (i.e., the ANT condition), participants significantly increased their early-stance hip extension moment, confirming that persons with transfemoral amputation rely on a hip extensor strategy to maintain knee joint stability. However, participants also decreased the rate at which they loaded their prosthesis, decreased their affected-side step length, increased their trunk flexion, and maintained their prosthesis in a more vertical posture at the time of opposite toe off. Collectively, these results suggest that persons with transfemoral amputation rely on a combination of strategies to coordinate stance-phase knee flexion. Further, comparatively few significant changes were observed in response to the POST condition, suggesting that a bias toward posterior alignment may have fewer implications in terms of stance-phase, knee joint control.

  4. Multi-Disciplinary Antimicrobial Strategies for Improving Orthopaedic Implants to Prevent Prosthetic Joint Infections in Hip and Knee

    PubMed Central

    Getzlaf, Matthew A.; Lewallen, Eric A.; Kremers, Hilal M.; Jones, Dakota L.; Bonin, Carolina A.; Dudakovic, Amel; Thaler, Roman; Cohen, Robert C.; Lewallen, David G.; van Wijnen, Andre J.

    2016-01-01

    Like any foreign object, orthopaedic implants are susceptible to infection when introduced into the human body. Without additional preventative measures, the absolute number of annual prosthetic joint infections will continue to rise, and may exceed the capacity of health care systems in the near future. Bacteria are difficult to eradicate from synovial joints due to their exceptionally diverse taxonomy, complex mechanistic attachment capabilities, and tendency to evolve antibiotic resistance. When a primary orthopaedic implant fails from prosthetic joint infection, surgeons are generally challenged by limited options for intervention. In this review, we highlight the etiology and taxonomic groupings of bacteria known to cause prosthetic joint infections, and examine their key mechanisms of attachment. We propose that antimicrobial strategies should focus on the most harmful bacteria taxa within the context of occurrence, taxonomic diversity, adhesion mechanisms, and implant design. Patient-specific identification of organisms that cause prosthetic joint infections will permit assessment of their biological vulnerabilities. The latter can be targeted using a range of antimicrobial techniques that exploit different colonization mechanisms including implant surface attachment, biofilm formation, and/or hematogenous recruitment. We anticipate that customized strategies for each patient, joint, and prosthetic component will be most effective at reducing prosthetic joint infections, including those caused by antibiotic-resistant and polymicrobial bacteria. PMID:26449208

  5. Obstructed bi-leaflet prosthetic mitral valve imaging with real-time three-dimensional transesophageal echocardiography.

    PubMed

    Shimbo, Mai; Watanabe, Hiroyuki; Kimura, Shunsuke; Terada, Mai; Iino, Takako; Iino, Kenji; Ito, Hiroshi

    2015-01-01

    Real-time three-dimensional transesophageal echocardiography (RT3D-TEE) can provide unique visualization and better understanding of the relationship among cardiac structures. Here, we report the case of an 85-year-old woman with an obstructed mitral prosthetic valve diagnosed promptly by RT3D-TEE, which clearly showed a leaflet stuck in the closed position. The opening and closing angles of the valve leaflets measured by RT3D-TEE were compatible with those measured by fluoroscopy. Moreover, RT3D-TEE revealed, in the ring of the prosthetic valve, thrombi that were not visible on fluoroscopy. RT3D-TEE might be a valuable diagnostic technique for prosthetic mitral valve thrombosis. © 2014 Wiley Periodicals, Inc.

  6. The History of Nontraditional or Ectopic Placement of Reservoirs in Prosthetic Urology.

    PubMed

    Perito, Paul; Wilson, Steven

    2016-04-01

    Reservoir placement during implantation of prosthetic urology devices has been problematic throughout the history of the surgical treatment of erectile dysfunction and urinary incontinence. We thought it would be interesting to review the history of reservoir placement leading up to current surgical techniques. To provide an overview of the past and present techniques for reservoir placement and discuss the evolutionary process leading to safe and effective placement of prosthetic reservoirs. We reviewed data pertaining to inflatable penile prosthesis (IPP) reservoirs and pressure-regulating balloons (PRB) in a chronological fashion, spanning 25 years. Main outcomes included a historical review of techniques for IPP reservoir and PRB placement leading to the subsequent incremental improvements in safety and efficacy when performing penile implants and artificial urinary sphincters. Prosthetic urologic reservoirs have traditionally been placed in the retropubic space. Over the years, urologists have attempted use of alternative spaces including peritoneal, epigastric, "ectopic," posterior to transversalis, and high submuscular. Current advances in prosthetic urologic reservoir placement allow safe and effective abdominal wall placement of reservoirs. These novel approaches appear to be so effective that urologists may now be able to cease using the traditional retropubic space for reservoir placement, even in the case of virgin pelves. Copyright © 2016 International Society for Sexual Medicine. Published by Elsevier Inc. All rights reserved.

  7. Assessment of dental prosthetic status and needs among prisoners of haryana, India.

    PubMed

    Bansal, Vikram; Veeresha, K L; Sogi, G M; Kumar, Adarsh; Bansal, Shelly

    2013-09-01

    This cross-sectional study was planned to evaluate the prosthetic status and treatment needs using WHO (1997) format among prisoners of Haryana state, India. 1,393 subjects with age range of 35.26 ± 12.29 years were examined. Of the study subjects, 11 (0.8 %) were completely while 606 (43.5 %) were partially edentulous. Of these 617 subjects, 305 (49.4 %) were edentulous only in posterior region. Dental caries accounted for loss of teeth in 325 (52.7 %) subjects. 44 (7.1 %) subjects were wearing some prosthesis. Regarding dental arch wise prosthetic need, 335 (54.3 %) subjects needed prosthesis in maxillary arch while 482 (78.1 %) needed prosthesis in mandibular arch. With advancing age there was an increase in the number of complete dental prosthesis required. There was no statistically significant difference between length of imprisonment and prosthetic need, except for need of a combination of prosthesis. Only one-fourth of the prisons had a dentist. The prisoners were taken to a hospital outside the prison in case of health needs. Prosthetic needs of prisoners were high. The lack of dental infrastructure in prisons makes the provision for multi-visit conservative dental treatments very difficult leading to higher tooth mortality. People who migrate back and forth across the prisons and communities represent a public health opportunity that should be addressed.

  8. Prosthetic mesh hernioplasty during laparoscopic radical prostatectomy.

    PubMed

    Teber, Dogu; Erdogru, Tibet; Zukosky, Derek; Frede, Thomas; Rassweiler, Jens

    2005-06-01

    To evaluate the role of simultaneous laparoscopic mesh prosthetic hernioplasty during laparoscopic radical prostatectomy (LRP), because 5% to 10% of candidates for radical prostatectomy present with a detectable inguinal hernia at their preoperative physical examination. Moreover, data have suggested a greater incidence of inguinal hernia after open radical prostatectomy. During 1035 LRP procedures, 50 laparoscopic mesh prosthetic hernioplasty procedures were performed in 37 patients (3.6%) for 13 bilateral and 24 unilateral inguinal hernias. We compared the outcome of LRP with simultaneous laparoscopic inguinal hernioplasty (group 1) with that of 37 match-paired patients treated by LRP alone (group 2). Both groups were matched according to age, prostate-specific antigen level, prostate volume, pathologic stage, and Gleason score. Perioperative parameters (ie, operative time, analgesic requirements) and postoperative results were analyzed. The patient age was 64.1 +/- 6.4 years versus 62.8 +/- 4.9 years old and had a body mass of 26.5 +/- 3.0 versus 27.4 +/- 3.2 kg/m2 in groups 1 and 2 (with and without laparoscopic hernioplasty), respectively. The mean operating time (221.9 versus 191.2 minutes, P = 0.011) and the total amount of narcotic analgesic requirements (26.8 mg versus 17.5 mg, P = 0.026) was significantly increased in the patients who underwent simultaneous laparoscopic inguinal hernia mesh repair. No statistically significant difference was found in the complication rate (4% versus 2%), median catheter time (7 days), and positive surgical margins (21.8%). Simultaneous repair of inguinal hernia during LRP using prosthetic mesh is feasible without adverse effects on surgical and functional parameters. Neither the transperitoneal nor extraperitoneal approach is associated with an increase in complications or morbidity. However, an extraperitoneal access allows an easier repair without the refixation of the peritoneum.

  9. Optimal design of a magnetorheological damper used in smart prosthetic knees

    NASA Astrophysics Data System (ADS)

    Gao, Fei; Liu, Yan-Nan; Liao, Wei-Hsin

    2017-03-01

    In this paper, a magnetorheological (MR) damper is optimally designed for use in smart prosthetic knees. The objective of optimization is to minimize the total energy consumption during one gait cycle and weight of the MR damper. Firstly, a smart prosthetic knee employing a DC motor, MR damper and springs is developed based on the kinetics characteristics of human knee during walking. Then the function of the MR damper is analyzed. In the initial stance phase and swing phase, the MR damper is powered off (off-state). While during the late stance phase, the MR damper is powered on to work as a clutch (on-state). Based on the MR damper model as well as the prosthetic knee model, the instantaneous energy consumption of the MR damper is derived in the two working states. Then by integrating in one gait cycle, the total energy consumption is obtained. Particle swarm optimization algorithm is used to optimize the geometric dimensions of MR damper. Finally, a prototype of the optimized MR damper is fabricated and tested with comparison to simulation.

  10. Standing on slopes - how current microprocessor-controlled prosthetic feet support transtibial and transfemoral amputees in an everyday task.

    PubMed

    Ernst, Michael; Altenburg, Björn; Bellmann, Malte; Schmalz, Thomas

    2017-11-16

    Conventional prosthetic feet like energy storage and return feet provide only a limited range of ankle motion compared to human ones. In order to overcome the poor rotational adaptability, prosthetic manufacturers developed different prosthetic feet with an additional rotational joint and implemented active control in different states. It was the aim of the study to investigate to what extent these commercially available microprocessor-controlled prosthetic feet support a natural posture while standing on inclines and which concept is most beneficial for lower limb amputees. Four unilateral transtibial and four unilateral transfemoral amputees participated in the study. Each of the subjects wore five different microprocessor-controlled prosthetic feet in addition to their everyday feet. The subjects were asked to stand on slopes of different inclinations (level ground, upward slope of 10°, and downward slope of -10°). Vertical ground reaction forces, joint torques and joint angles in the sagittal plane were measured for both legs separately for the different situations and compared to a non-amputee reference group. Differences in the biomechanical parameters were observed between the different prosthetic feet and compared to the reference group for the investigated situations. They were most prominent while standing on a downward slope. For example, on the prosthetic side, the vertical ground reaction force is reduced by about 20%, and the torque about the knee acts to flex the joint for feet that are not capable of a full adaptation to the downward slope. In contrast, fully adaptable feet with an auto-adaptive dorsiflexion stop show no changes in vertical ground reaction forces and knee extending torques. A prosthetic foot that provides both, an auto-adaptive dorsiflexion stop and a sufficient range of motion for fully adapting to inclinations appears to be the key element in the prosthetic fitting for standing on inclinations in lower limb amputees. In such

  11. Prosthetic Hand With Two Gripping Fingers

    NASA Technical Reports Server (NTRS)

    Norton, William E.; Belcher, Jewell B.; Vest, Thomas W.; Carden, James R.

    1993-01-01

    Prosthetic hand developed for amputee who retains significant portion of forearm. Outer end of device is end effector including two fingers, one moved by rotating remaining part of forearm about its longitudinal axis. Main body of end effector is end member supporting fingers, roller bearing assembly, and rack-and-pinion mechanism. Advantage of rack-and-pinion mechanism enables user to open or close gap between fingers with precision and force.

  12. Energy expenditure of wheeling and walking during prosthetic rehabilitation in a woman with bilateral transfemoral amputations.

    PubMed

    Wu, Y J; Chen, S Y; Lin, M C; Lan, C; Lai, J S; Lien, I N

    2001-02-01

    To compare the energy expenditure of locomotion by wheelchair with that required for prosthetic ambulation in a person with bilateral transfemoral (TF) amputations. Observational, single patient, descriptive. An 80-meter long rectangular hallway in a rehabilitation unit. A 41-year-old woman with bilateral TF amputations that were performed 79 days before her admission to the rehabilitation unit. The oxygen uptake, oxygen cost, heart rate, speed, cadence, and stride length of walking measured during a 4-month course of prosthetic rehabilitation. Five locomotion conditions were evaluated: (1) wheelchair propulsion, (2) walking with short-leg prostheses (stubbies) and a walker, (3) long-leg prostheses and a walker, (4) long-leg prostheses without knee mechanism and axillary crutches, and (5) long-leg prostheses with right polycentric knee and left locked knee and axillary crutches. A portable and telemetric system was used to measure the metabolic parameters. An arm ergometry graded exercise test was performed at the end of rehabilitation. Oxygen cost (range, 466%--707% of that of wheeling) and heart rate (range, 106%--116% of that of wheeling) were higher during walking with various combinations of prostheses and walking aids. The speed of prosthetic walking was only 24% to 33% of that of wheeling. Our patient preferred using a wheelchair to prosthetic walking after discharge. People with bilateral TF amputations require very high cardiorespiratory endurance to fulfill the energy demand during prosthetic rehabilitation. The high energy cost of prosthetic walking will limit its application in daily activities.

  13. [Microbiological characteristics and patterns of resistance in prosthetic joint infections in a referral hospital].

    PubMed

    Ortega-Peña, Silvestre; Colín-Castro, Claudia; Hernández-Duran, Melissa; López-Jácome, Esaú; Franco-Cendejas, Rafael

    2015-01-01

    The prosthetic joint infection is the most feared and catastrophic complication for cause severe physical damage to patients and, generates high economic costs. To describe the microbiological characteristics and to determine the resistance pattern in prosthetic joint infections in a reference hospital in Mexico. Patients whose prosthetic devices were withdrawn due to suspicion of septic and aseptic loosening were included. Cultures were performed to identify microorganisms and susceptibility analysis. Of the 111 patients included, 55% were diagnosed with prosthetic joint infection, with the most frequent prosthesis being of the hip (43%). Positive cultures were obtained in 97% of the infected cases, of which 75% were monomicrobial infections. The most frequent bacterial species isolated were: Staphylococcus epidermidis (31%), Enterococcus faecalis (16%), Staphylococcus aureus (13%), and Escherichia coli (8%). The resistance patterns for the Staphylococcus genus were: oxacillin (79%), erythromycin (45%) and ciprofloxacin (37%). Enterococcus faecalis showed a high percentage of resistance to erythromycin and clindamycin (86%), and fluoroquinolones (43%). The large majority (86%) of Escherichia coli were extended spectrum beta-lactamases positive, in addition to having high resistance to fluoroquinolones (86%), trimethoprim/sulfamethoxazole (86%) and gentamicin (72%). The microbiological characteristics found in prosthetic joint infections vary according to the hospitals. In this series, a high proportion of coagulase-negative Staphylococci and Enterococcus spp. were found, as well as a high bacterial resistance. Copyright © 2015 Academia Mexicana de Cirugía A.C. Published by Masson Doyma México S.A. All rights reserved.

  14. Prosthetic joint infection caused by Granulicatella adiacens: a case series and review of literature.

    PubMed

    Quénard, Fanny; Seng, Piseth; Lagier, Jean-Christophe; Fenollar, Florence; Stein, Andreas

    2017-06-23

    Bone and joint infection involving Granulicatella adiacens is rare, and mainly involved in cases of bacteremia and infectious endocarditis. Here we report three cases of prosthetic joint infection involving G. adiacens that were successfully treated with surgery and prolonged antimicrobial treatment. We also review the two cases of prosthetic joint infection involving G. adiacens that are reported in the literature. Not all five cases of prosthetic joint infection caused by G. adiacens were associated with bacteremia or infectious endocarditis. Dental care before the onset of infection was observed in two cases. The median time delay between arthroplasty implantation and the onset of infection was of 4 years (ranging between 2 and 10 years). One of our cases was identified with 16srRNA gene sequencing, one case with MALDI-TOF mass spectrometry, and one case with both techniques. Two literature cases were diagnosed by 16srRNA gene sequencing. All five cases were cured after surgery including a two-stage prosthesis exchange in three cases, a one-stage prosthesis exchange in one case, and debridement, antibiotics, irrigation, and retention of the prosthesis in one case, and prolonged antimicrobial treatment. Prosthetic joint infection involving G. adiacens is probably often dismissed due to difficult culture or misdiagnosis, in particular in the cases of polymicrobial infection. Debridement, antibiotics, irrigation, and retention of the prosthesis associated with prolonged antimicrobial treatment (≥ 8 weeks) should be considered as a treatment strategy for prosthetic joint infection involving G. adiacens.

  15. Expert opinions on success factors for upper-limb prostheses.

    PubMed

    Schultz, Aimee E; Baade, Susan P; Kuiken, Todd A

    2007-01-01

    The goal of this study was to gather the opinions of prosthetics experts on the most important factors for the successful use of upper-limb (UL) prostheses, compare them with those of prosthesis users, and ultimately direct research efforts in this field. UL prosthetics experts were asked to compare the importance of the comfort, function, and cosmesis of a prosthetic device for a transhumeral amputee. Categories were subdivided into weight, socket-interface comfort, power, agility, color, and shape. The majority of those who responded viewed comfort as the most important factor for a unilateral amputee and considered socket-interface comfort to be more important than weight. Function was considered to be the most important factor for a bilateral amputee, with agility considered more important than power. Cosmesis was consistently reported as being less important than comfort and function, and shape was considered more important than color.

  16. Usefulness of Mitral Valve Prosthetic or Bioprosthetic Time Velocity Index Ratio to Detect Prosthetic or Bioprosthetic Mitral Valve Dysfunction.

    PubMed

    Luis, Sushil Allen; Blauwet, Lori A; Samardhi, Himabindu; West, Cathy; Mehta, Ramila A; Luis, Chris R; Scalia, Gregory M; Miller, Fletcher A; Burstow, Darryl J

    2017-10-15

    This study aimed to investigate the utility of transthoracic echocardiographic (TTE) Doppler-derived parameters in detection of mitral prosthetic dysfunction and to define optimal cut-off values for identification of such dysfunction by valve type. In total, 971 TTE studies (647 mechanical prostheses; 324 bioprostheses) were compared with transesophageal echocardiography for evaluation of mitral prosthesis function. Among all prostheses, mitral valve prosthesis (MVP) ratio (ratio of time velocity integral of MVP to that of left ventricular outflow tract; odds ratio [OR] 10.34, 95% confidence interval [95% CI] 6.43 to 16.61, p<0.001), E velocity (OR 3.23, 95% CI 1.61 to 6.47, p<0.001), and mean gradient (OR 1.13, 95% CI 1.02 to 1.25, p=0.02) provided good discrimination of clinically normal and clinically abnormal prostheses. Optimal cut-off values by receiver operating characteristic analysis for differentiating clinically normal and abnormal prostheses varied by prosthesis type. Combining MVP ratio and E velocity improved specificity (92%) and positive predictive value (65%) compared with either parameter alone, with minimal decline in negative predictive value (92%). Pressure halftime (OR 0.99, 95% CI 0.98 to 1.00, p=0.04) did not differentiate between clinically normal and clinically abnormal prostheses but was useful in discriminating obstructed from normal and regurgitant prostheses. In conclusion, cut-off values for TTE-derived Doppler parameters of MVP function were specific to prosthesis type and carried high sensitivity and specificity for identifying prosthetic valve dysfunction. MVP ratio was the best predictor of prosthetic dysfunction and, combined with E velocity, provided a useful parameter for determining likelihood of dysfunction and need for further assessment. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.

  17. Extrinsic mechanism obstructing the opening of a prosthetic mitral valve: an unusual case of suture entrapment.

    PubMed

    Ozkan, Mehmet; Astarcioglu, Mehmet Ali; Karakoyun, Suleyman; Balkanay, Mehmet

    2012-02-01

    Obstruction to a prosthetic cardiac valve is a well-recognized complication of cardiac valve replacement. Malfunction of the mobile component of a prosthetic valve to open or close correctly may occur in consequence of intrinsic or extrinsic causes (thrombus, vegetation, entrapment of left ventricular myocardium, suture entanglement, and pannus formation) that may result prosthetic valve stenosis and/or insufficiency. In the case we report a 48-year-old female with valve dysfunction occurred early after surgery, as one valve leaflet was only able to partially open due to suture entrapment. © 2011, Wiley Periodicals, Inc.

  18. Phonological Awareness: Factors of Influence

    ERIC Educational Resources Information Center

    Frohlich, Linda Paulina; Petermann, Franz; Metz, Dorothee

    2013-01-01

    Early child development is influenced by various genetic and environmental factors. This study aims to identify factors that affect the phonological awareness of preschool and first grade children. Based on a sample of 330 German-speaking children (mean age = 6.2 years) the following domains were evaluated: Parent factors, birth and pregnancy,…

  19. Technical Report: A device to monitor sock use on people using prosthetic limbs

    PubMed Central

    Sanders, Joan; Murthy, Revathi; Cagle, John; Allyn, Katheryn; Phillips, Reid

    2015-01-01

    A device using radio frequency identification technology (RFID) was developed to continuously monitor sock use on people using prosthetic limbs. RFID tags were placed on prosthetic socks worn by subjects with transtibial limb loss, and a high-frequency (HF) RFID reader and antenna were placed in a portable unit mounted to the outside of the prosthetic socket. Bench testing showed the device to have a maximum read range between 5.6 cm and 12.7 cm, depending on the RFID tag used. Testing in a laboratory setting on three participants with transtibial amputation showed that the device correctly monitored sock presence during sitting, standing, and walking activity when one or two socks were worn but was less reliable when more socks were used. Accurate detection was sensitive to orientation of the tag relative to the reader, presence of carbon fiber in the prosthetic socket, pistoning of the limb in the socket, and overlap among the tags. Use of ultra high frequency (UHF) RFID may overcome these limitations. With improvements, the technology may prove useful to practitioners prescribing volume accommodation strategies for patients by providing information about sock use between clinical visits, including timing and consistency of daily sock ply changes. PMID:23341315

  20. Retrieval of a leaflet escaped in a Tri-technologies bileaflet mechanical prosthetic valve.

    PubMed

    Cianciulli, Tomás F; Lax, Jorge A; Saccheri, María C; Guidoin, Robert; Salvado, César M; Fernández, Adrián J; Prezioso, Horacio A

    2008-01-01

    The escape of the prosthetic heart valve disc is one of the causes of prosthetic dysfunction that requires emergency surgery. The removal of the embolized disc should be carried out because of the risk of a progressive extrusion on the aortic wall. Several imaging techniques can be used for the detection of the missing disc localization. In this report we describe a 32-year-old man who underwent mitral valve replacement with a Tri-technologies bileaflet valve three years ago, and was admitted in cardiogenic shock. Transesophageal echocardiography showed acute-onset massive mitral regurgitation. The patient underwent emergency replacement of the prosthetic valve. Only one of the two leaflets remained in the removed prosthetic valve. The missing leaflet could not be found within the cardiac cavity. The abdominal fluoroscopic study and plain radiography were unable to detect the escaped leaflet. The abdominal computed tomography scan and the ultrasound showed the escaped leaflet in the terminal portion of the aortic bifurcation. To retrieve the embolized disc laparotomy and aortotomy were performed three months later. The escaped leaflet shows a fracture of one of the pivot systems caused by structural failure. This kind of failure mode is usually the result of high stress concentration.

  1. Hydrodynamic endurance test of the prosthetic valve used in the various types of the ventricular assist device.

    PubMed

    Nitta, S; Yambe, T; Katahira, Y; Sonobe, T; Saijoh, Y; Naganuma, S; Akiho, H; Kakinuma, Y; Tanaka, M; Miura, M

    1991-12-01

    To evaluate the various basic designs of the pump chambers used in the ventricular assist devices (VADs), hydrodynamic endurance test was performed from the viewpoint of the durability of the prosthetic valves used in the VAD. For the hydrodynamic analysis, we designed three basic types of pump (sac type, diaphragm type, and pusher plate type) using the same material and having the same capacity and shape. Prosthetic valves in these VADs were tested from the standpoint of the water hammer effect, which affects the valve durability, to determine which pump design would be most durable as a prosthetic valve in the VAD. The water-hammer phenomenon was evaluated using the maximum pressure gradient (MPG) across the prosthetic valve in the moc circulatory loop. Maximum pump output was recorded when we used the diaphragm type model, and minimum MPG in the commonly used driving condition of the VAD were recorded when we used the sac type model. The results suggest that the sac type VAD model is the most durable design for the prosthetic value.

  2. Biological response to prosthetic debris

    PubMed Central

    Bitar, Diana; Parvizi, Javad

    2015-01-01

    Joint arthroplasty had revolutionized the outcome of orthopaedic surgery. Extensive and collaborative work of many innovator surgeons had led to the development of durable bearing surfaces, yet no single material is considered absolutely perfect. Generation of wear debris from any part of the prosthesis is unavoidable. Implant loosening secondary to osteolysis is the most common mode of failure of arthroplasty. Osteolysis is the resultant of complex contribution of the generated wear debris and the mechanical instability of the prosthetic components. Roughly speaking, all orthopedic biomaterials may induce a universal biologic host response to generated wear débris with little specific characteristics for each material; but some debris has been shown to be more cytotoxic than others. Prosthetic wear debris induces an extensive biological cascade of adverse cellular responses, where macrophages are the main cellular type involved in this hostile inflammatory process. Macrophages cause osteolysis indirectly by releasing numerous chemotactic inflammatory mediators, and directly by resorbing bone with their membrane microstructures. The bio-reactivity of wear particles depends on two major elements: particle characteristics (size, concentration and composition) and host characteristics. While any particle type may enhance hostile cellular reaction, cytological examination demonstrated that more than 70% of the debris burden is constituted of polyethylene particles. Comprehensive understanding of the intricate process of osteolysis is of utmost importance for future development of therapeutic modalities that may delay or prevent the disease progression. PMID:25793158

  3. A review of extra-articular prosthetic stabilization of the cranial cruciate ligament-deficient stifle.

    PubMed

    Tonks, C A; Lewis, D D; Pozzi, A

    2011-01-01

    Extra-articular prosthetic stabilization techniques have been used as a method of stabilization of the cranial cruciate ligament (CrCL)-deficient stifle for decades. During extra-articular prosthetic stabilization, the prosthesis is anchored to the femur and tibia, and tensioned in the attempt to resolve femorotibial instability. The position of the anchor points of the prosthesis is crucial for restoring a normal range of joint motion and mitigating alterations in prosthesis tension during motion. Recently developed techniques offer several innovations with potential advantages such as bone-to-bone fixation, prosthetic materials with better mechanical properties, and improved isometry of the anchor points. Whether these innovations provide clinically superior results to the traditional techniques such as lateral circumfabellar-tibial suture techniques has yet to be determined.

  4. Prosthetic aortic valve endocarditis complicated with annular abscess, sub-aortic obstruction and valve dehiscence.

    PubMed

    Hassoulas, Joannis; Patrianakos, Alexandros P; Parthenakis, Fragiskos I; Vardas, Panos E

    2009-01-01

    We present a 76-year-old woman with infective endocarditis of a prosthetic aortic valve. The course of her illness started with an ischaemic stroke and she was admitted with prolonged fever and an episode of loss of consciousness. Echocardiography revealed acute aortic regurgitation and dehiscence of the prosthetic valve with excessive "rocking motion", aortic abscesses and left ventricular outflow obstruction caused by a semilunar shelf of tissue probably due to endocarditis vegetations. She underwent an urgent surgical procedure that confirmed the echocardiographic findings. Our case report reinforces the value of early diagnosis in the presence of a high clinical suspicion of prosthetic valve endocarditis. An extended workup, including transoesophageal echocardiography, in such a patient with a mechanical valve is mandatory.

  5. Prosthetic Hand For Holding Rods, Tools, And Handles

    NASA Technical Reports Server (NTRS)

    Belcher, Jewell G., Jr.; Vest, Thomas W.

    1995-01-01

    Prosthetic hand with quick-grip/quick-release lever broadens range of specialized functions available to lower-arm amputee by providing improved capabilities for gripping rods, tools, handles, and like. Includes two stationary lower fingers opposed by one pivoting upper finger. Lever operates in conjunction with attached bracket.

  6. Cyborg beast: a low-cost 3d-printed prosthetic hand for children with upper-limb differences.

    PubMed

    Zuniga, Jorge; Katsavelis, Dimitrios; Peck, Jean; Stollberg, John; Petrykowski, Marc; Carson, Adam; Fernandez, Cristina

    2015-01-20

    There is an increasing number of children with traumatic and congenital hand amputations or reductions. Children's prosthetic needs are complex due to their small size, constant growth, and psychosocial development. Families' financial resources play a crucial role in the prescription of prostheses for their children, especially when private insurance and public funding are insufficient. Electric-powered (i.e., myoelectric) and body-powered (i.e., mechanical) devices have been developed to accommodate children's needs, but the cost of maintenance and replacement represents an obstacle for many families. Due to the complexity and high cost of these prosthetic hands, they are not accessible to children from low-income, uninsured families or to children from developing countries. Advancements in computer-aided design (CAD) programs, additive manufacturing, and image editing software offer the possibility of designing, printing, and fitting prosthetic hands devices at a distance and at very low cost. The purpose of this preliminary investigation was to describe a low-cost three-dimensional (3D)-printed prosthetic hand for children with upper-limb reductions and to propose a prosthesis fitting methodology that can be performed at a distance. No significant mean differences were found between the anthropometric and range of motion measurements taken directly from the upper limbs of subjects versus those extracted from photographs. The Bland and Altman plots show no major bias and narrow limits of agreements for lengths and widths and small bias and wider limits of agreements for the range of motion measurements. The main finding of the survey was that our prosthetic device may have a significant potential to positively impact quality of life and daily usage, and can be incorporated in several activities at home and in school. This investigation describes a low-cost 3D-printed prosthetic hand for children and proposes a distance fitting procedure. The Cyborg Beast

  7. Allograft-prosthetic composite reverse total shoulder arthroplasty for reconstruction of proximal humerus tumor resections.

    PubMed

    King, Joseph J; Nystrom, Lukas M; Reimer, Nickolas B; Gibbs, C Parker; Scarborough, Mark T; Wright, Thomas W

    2016-01-01

    Proximal humerus reconstructions after resection of tumors are challenging. Early success of the reverse shoulder arthroplasty for reconstructions has recently been reported. The reverse allograft-prosthetic composite offers the advantage of improved glenohumeral stability compared with hemiarthroplasty for proximal humeral reconstructions as it uses the deltoid for stability. This article describes the technique for treating proximal humeral tumors, including preoperative planning, biopsy principles, resection pearls, soft tissue tensioning, and specifics about reconstruction using the reverse allograft-prosthetic composite. Two cases are presented along with the functional outcomes with use of this technique. Biomechanical considerations during reconstruction are reviewed, including techniques to improve the deltoid compression force. Reported instability rates are less with reverse shoulder arthroplasty reconstruction as opposed to hemiarthroplasty or total shoulder arthroplasty reconstructions of tumor resections. Reported functional outcomes are promising for the reverse allograft-prosthetic composite reconstructions, although complications are reported. Reverse allograft-prosthetic composites are a promising option for proximal humeral reconstructions, although nonunion of the allograft-host bone junction continues to be a challenge for this technique. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  8. Prosthetic vascular graft infection through a median sternotomy: a multicentre review †.

    PubMed

    Oda, Tatsuya; Minatoya, Kenji; Kobayashi, Junjiro; Okita, Yutaka; Akashi, Hidetoshi; Tanaka, Hiroyuki; Kawaharada, Nobuyoshi; Saiki, Yoshikatsu; Kuniyoshi, Yukio; Nishimura, Kunihiro

    2015-06-01

    The aim of this study is to analyse the treatment outcomes of thoracic prosthetic graft infection. A retrospective chart review was conducted at six hospitals and included the records of 68 patients treated for postoperative prosthetic vascular graft infection (mean age: 62.3 ± 15.1, male 51) from January 2000 to December 2013. The number of patients and the locations of the treated infections were as follows: 13 for aortic root, 16 for ascending aorta, 35 for aortic arch and 4 for aortic root to arch. In-hospital infection occurred in 43 patients and after discharge in 25. The mean follow-up time was 2.0 ± 2.3 years. The follow-up rate was 94.1%. The most commonly isolated micro-organism was Staphylococcus aureus (72.1%). Rereplacement of infectious graft was performed in 18 patients (Dacron graft in 12, homograft in 4 and rifampicin-bonded Dacron graft in 2). The overall hospital mortality rate was 35.3% (24/68). The mortality rate among the patients with graft rereplacement was 33.3% (6/18), with pedicled muscle flaps or pedicled omental flaps to cover the graft 25.9% (7/27), with irrigation 55.0% (11/20) and on antibiotic therapy only 0% (0/3). Our multivariate analysis demonstrated that the risk factors of hospital death increased in the absence of pedicled flaps (muscle or omentum) to cover the graft (P = 0.001), age over 55 (P = 0.003), time from onset of initial operation <1 week (P = 0.031) and period before 2008 (P = 0.001). The overall 1-year survival rate was 58.6%. The treatment outcomes of thoracic prosthetic vascular graft infection have not been satisfactory. However, the use of pedicled muscle or omental flaps to cover the graft could improve the outcomes. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  9. Novel design of electrical sensing interface for prosthetic limbs using optical micro cavities

    NASA Astrophysics Data System (ADS)

    Ali, Amir R.; Kamel, Mohamed A.

    2018-04-01

    This paper uses optical whispering galley modes (WGM) cavities to construct a new electrical sensing interface between prosthetic limb and the brain. The sensing element will detect the action potential signal in the neural membrane and the prosthetic limb will be actuated accordingly. The element is a WGM dielectric polymeric cavity. WGM based optical cavities can achieve very high values of sensitivity and quality factor; thus, any minute perturbations in the morphology of the cavity can be captured and measured. The action potential signal will produce an applied external electric field on the dielectric cavity causing it to deform due to the electrostriction effect. The resulting deformation will cause WGM shifts in the transmission spectrum of the cavity. Thus, the action potential or the applied electric field can be measured using these shifts. In this paper the action potential signal will be simulated through the use of a function generator and two metal electrodes. The sensing element will be situated between these electrodes to detect the electrical signal passing through. The achieved sensitivity is 27.5 pm/V in measuring the simulated action potential signal; and 0.32 pm/V.m-1 in measuring the applied electric field due to the passage of the simulated signal.

  10. Prosthetic finger phalanges with lifelike skin compliance for low-force social touching interactions

    PubMed Central

    2011-01-01

    Background Prosthetic arms and hands that can be controlled by the user's electromyography (EMG) signals are emerging. Eventually, these advanced prosthetic devices will be expected to touch and be touched by other people. As realistic as they may look, the currently available prosthetic hands have physical properties that are still far from the characteristics of human skins because they are much stiffer. In this paper, different configurations of synthetic finger phalanges have been investigated for their skin compliance behaviour and have been compared with the phalanges of the human fingers and a phalanx from a commercially available prosthetic hand. Methods Handshake tests were performed to identify which areas on the human hand experience high contact forces. After these areas were determined, experiments were done on selected areas using an indenting probe to obtain the force-displacement curves. Finite element simulations were used to compare the force-displacement results of the synthetic finger phalanx designs with that of the experimental results from the human and prosthetic finger phalanges. The simulation models were used to investigate the effects of (a) varying the internal topology of the finger phalanx and (b) varying different materials for the internal and external layers. Results and Conclusions During handshake, the high magnitudes of contact forces were observed at the areas where the full grasping enclosure of the other person's hand can be achieved. From these areas, the middle phalanges of the (a) little, (b) ring, and (c) middle fingers were selected. The indentation experiments on these areas showed that a 2 N force corresponds to skin tissue displacements of more than 2 mm. The results from the simulation model show that introducing an open pocket with 2 mm height on the internal structure of synthetic finger phalanges increased the skin compliance of the silicone material to 235% and the polyurethane material to 436%, as compared to a

  11. Peri‐prosthetic tissue cells show osteogenic capacity to differentiate into the osteoblastic lineage

    PubMed Central

    Schoeman, Monique A.E.; Oostlander, Angela E.; Rooij, Karien Ede; Valstar, Edward R.

    2017-01-01

    ABSTRACT During the process of aseptic loosening of prostheses, particulate wear debris induces a continuous inflammatory‐like response resulting in the formation of a layer of fibrous peri‐prosthetic tissue at the bone‐prosthesis interface. The current treatment for loosening is revision surgery which is associated with a high‐morbidity rate, especially in old patients. Therefore, less invasive alternatives are necessary. One approach could be to re‐establish osseointegration of the prosthesis by inducing osteoblast differentiation in the peri‐prosthetic tissue. Therefore, the aim of this study was to investigate the capacity of peri‐prosthetic tissue cells to differentiate into the osteoblast lineage. Cells isolated from peri‐prosthetic tissue samples (n = 22)−obtained during revision surgeries−were cultured under normal and several osteogenic culture conditions. Osteogenic differentiation was assessed by measurement of Alkaline Phosphatse (ALP), mineralization of the matrix and expression of several osteogenic genes. Cells cultured in osteogenic medium showed a significant increase in ALP staining (p = 0.024), mineralization of the matrix (p < 0.001) and ALP gene expression (p = 0.014) compared to normal culture medium. Addition of bone morphogenetic proteins (BMPs), a specific GSK3β inhibitor (GIN) or a combination of BMP and GIN to osteogenic medium could not increase ALP staining, mineralization, and ALP gene expression. In one donor, addition of GIN was required to induce mineralization of the matrix. Overall, we observed a high‐inter‐donor variability in response to osteogenic stimuli. In conclusion, peri‐prosthetic tissue cells, cultured under osteogenic conditions, can produce alkaline phosphatase and mineralized matrix, and therefore show characteristics of differentiation into the osteoblastic lineage. © 2016 The Authors. Journal of Orthopaedic Research published by Wiley Periodicals, Inc. on behalf of

  12. Impact of pannus formation on hemodynamic dysfunction of prosthetic aortic valve: pannus extent and its relationship to prosthetic valve motion and degree of stenosis.

    PubMed

    Koo, Hyun Jung; Ha, Hojin; Kang, Joon-Won; Kim, Jeong A; Song, Jae-Kwan; Kim, Hwa Jung; Lim, Tae-Hwan; Yang, Dong Hyun

    2018-02-19

    Although pannus is an important cause of prosthetic valve dysfunction, the minimum pannus size that can induce hemodynamic dysfunction has not yet been determined. This study investigated the correlation between the limitation of motion (LOM) of the prosthetic valve and pannus extent and determined the pannus extent that could induce severe aortic stenosis. This study included 49 patients who underwent mechanical aortic valve replacement (AVR) and showed pannus on cardiac computed tomography (CT). Pannus width, ratio of pannus width to valve diameter, pannus area, effective orifice area, encroachment ratio by pannus, pannus involvement angle and percent LOM of mechanical valves were evaluated on CT. Transvalvular peak velocity (TPV) and transvalvular pressure gradient (TPG) were measured by transesophageal echocardiography to determine the degree of aortic stenosis. The relationship between percent LOM of the prosthetic valve and pannus extent and the cut-off of pannus extent required to induce severe aortic stenosis were evaluated. The mean interval between AVR and pannus formation was 11 years and was longer in patients with than without severe aortic stenosis (14.0 vs. 7.3 years). On CT, the percent LOM of the prosthetic valve was significantly associated with the extent of pannus only in patients with pannus involvement angle > 180° (r = 0.55-0.68, P < 0.01). Pannus width, effective orifice area, and encroachment ratio were significantly associated with increased TPV and TPG (r = 0.51-0.62, P < 0.01). Pannus width > 3.5 mm, pannus width/valve inner diameter > 0.15, and encroachment ratio > 0.14 were significantly associated with severe aortic stenosis (TPV > 4 m/s; mean TPG ≥ 35 mmHg), with c-indices of 0.74-079 (P < 0.005). CT-derived pannus extent parameters are good indicators of significant hemodynamic changes with increased TPV and mean TPG.

  13. OSU-Okmulgee's Orthotics and Prosthetics Technician Program Thrives

    ERIC Educational Resources Information Center

    Smith, Sharon

    2007-01-01

    Students in the Orthotics and Prosthetics Technician Program at Oklahoma State University (OSU)-Okmulgee are provided with opportunities to develop multiple skill sets coveted by employers that will land them jobs in the industry as technicians, fitters or pedorthists. The program was recently restructured to become a technically based orthotic…

  14. Pursuing prosthetic electronic skin

    NASA Astrophysics Data System (ADS)

    Chortos, Alex; Liu, Jia; Bao, Zhenan

    2016-09-01

    Skin plays an important role in mediating our interactions with the world. Recreating the properties of skin using electronic devices could have profound implications for prosthetics and medicine. The pursuit of artificial skin has inspired innovations in materials to imitate skin's unique characteristics, including mechanical durability and stretchability, biodegradability, and the ability to measure a diversity of complex sensations over large areas. New materials and fabrication strategies are being developed to make mechanically compliant and multifunctional skin-like electronics, and improve brain/machine interfaces that enable transmission of the skin's signals into the body. This Review will cover materials and devices designed for mimicking the skin's ability to sense and generate biomimetic signals.

  15. Single-stage revision for fungal peri-prosthetic joint infection: a single-centre experience.

    PubMed

    Klatte, T O; Kendoff, D; Kamath, A F; Jonen, V; Rueger, J M; Frommelt, L; Gebauer, M; Gehrke, T

    2014-04-01

    Fungal peri-prosthetic infections of the knee and hip are rare but likely to result in devastating complications. In this study we evaluated the results of their management using a single-stage exchange technique. Between 2001 and 2011, 14 patients (ten hips, four knees) were treated for a peri-prosthetic fungal infection. One patient was excluded because revision surgery was not possible owing to a large acetabular defect. One patient developed a further infection two months post-operatively and was excluded from the analysis. Two patients died of unrelated causes. After a mean of seven years (3 to 11) a total of ten patients were available for follow-up. One patient, undergoing revision replacement of the hip, had a post-operative dislocation. Another patient, undergoing revision replacement of the knee, developed a wound infection and required revision 29 months post-operatively following a peri-prosthetic femoral fracture. The mean Harris hip score increased to 74 points (63 to 84; p < 0.02) in those undergoing revision replacement of the hip, and the mean Hospital for Special Surgery knee score increased to 75 points (70 to 80; p < 0.01) in those undergoing revision replacement of the knee. A single-stage revision following fungal peri-prosthetic infection is feasible, with an acceptable rate of a satisfactory outcome.

  16. Candida-induced prosthetic joint infection. A literature review including 72 cases and a case report.

    PubMed

    Cobo, Fernando; Rodríguez-Granger, Javier; López, Enrique M; Jiménez, Gemma; Sampedro, Antonio; Aliaga-Martínez, Luis; Navarro-Marí, José María

    2017-02-01

    The clinical and microbiological characteristics of prosthetic joint infection (PJI) caused by Candida species is described, including 72 cases in the literature and a case of Candida glabrata infection handled at the present centre. We describe one patient and using the key words 'fungal prosthetic joint infection' and 'candida prosthetic joint infection' we searched MEDLINE (National Library of Medicine, Bethesda, MD), Web of Science, CINAHL and Cochrane systematic review databases for case reports of this condition. Out of the 73 patients, 38 were female; mean age at diagnosis was 65.7 (± SD 18) yrs; 50 had risk factors for candidal infection such as systemic disease (e.g. rheumatoid arthritis, Sjogren's syndrome, systemic lupus erythematosus) and/or immunosuppressive therapy in 18 (24.6%) cases, diabetes mellitus in 14 (19.1%), immunosuppression due to malignant or chronic disease in 24 (32.8%) and long-term antibiotic use in four (5.4%) patients. Infection site was the knee in 36 patients and hip in 35; pain was present in 43 patients and swelling in 23 and the mean surgery-diagnosis interval was 32 months. The most frequent species was C. albicans, followed by C. parapsilosis. The diagnosis was obtained from joint fluid aspirate in 33 cases and intra-operative samples in 16. Susceptibility to antifungals was tested in only 21 isolates. The most frequently used antifungals were fluconazole and amphotericin B. Two-stage exchange arthroplasty was performed in 30 patients and resection arthroplasty in 31; 56 patients were cured with a combination of medical and surgical treatment; one patient died from the infection. PJI caused by Candida requires a high index of suspicion; surgery with long-term antifungal therapy is recommended.

  17. Managing uncertainty - a qualitative study of surgeons' decision-making for one-stage and two-stage revision surgery for prosthetic hip joint infection.

    PubMed

    Moore, Andrew J; Blom, Ashley W; Whitehouse, Michael R; Gooberman-Hill, Rachael

    2017-04-12

    Approximately 88,000 primary hip replacements are performed in England and Wales each year. Around 1% go on to develop deep prosthetic joint infection. Between one-stage and two-stage revision arthroplasty best treatment options remain unclear. Our aims were to characterise consultant orthopaedic surgeons' decisions about performing either one-stage or two-stage revision surgery for patients with deep prosthetic infection (PJI) after hip arthroplasty, and to identify whether a randomised trial comparing one-stage with two-stage revision would be feasible. Semi-structured interviews were conducted with 12 consultant surgeons who perform revision surgery for PJI after hip arthroplasty at 5 high-volume National Health Service (NHS) orthopaedic departments in England and Wales. Surgeons were interviewed before the development of a multicentre randomised controlled trial. Data were analysed using a thematic approach. There is no single standardised surgical intervention for the treatment of PJI. Surgeons balance multiple factors when choosing a surgical strategy which include multiple patient-related factors, their own knowledge and expertise, available infrastructure and the infecting organism. Surgeons questioned whether it was appropriate that the two-stage revision remained the best treatment, and some surgeons' willingness to consider more one-stage revisions had increased over recent years and were influenced by growing evidence showing equivalence between surgical techniques, and local observations of successful one-stage revisions. Custom-made articulating spacers was a practice that enabled uncertainty to be managed in the absence of definitive evidence about the superiority of one surgical technique over the other. Surgeons highlighted the need for research evidence to inform practice and thought that a randomised trial to compare treatments was needed. Most surgeons thought that patients who they treated would be eligible for trial participation in instances

  18. Factors that Influence Participation in Online Learning

    ERIC Educational Resources Information Center

    Vonderwell, Selma; Zachariah, Sajit

    2005-01-01

    This study explored what factors influenced learner participation in two sections of a graduate online course at a Midwestern university. Findings indicated that online learner participation and patterns of participation are influenced by the following factors: technology and interface characteristics, content area experience, student roles and…

  19. Distal anastomotic vein adjunct usage in infrainguinal prosthetic bypasses.

    PubMed

    McPhee, James T; Goodney, Philip P; Schanzer, Andres; Shaykevich, Shimon; Belkin, Michael; Menard, Matthew T

    2013-04-01

    Single-segment saphenous vein remains the optimal conduit for infrainguinal revascularization. In its absence, prosthetic conduit may be used. Existing data regarding the significance of anastomotic distal vein adjunct (DVA) usage with prosthetic grafts are based on small series. This is a retrospective cohort analysis derived from the regional Vascular Study Group of New England as well as the Brigham and Women's hospital database. A total of 1018 infrainguinal prosthetic bypass grafts were captured in the dataset from 73 surgeons at 15 participating institutions. Propensity scoring and 3:1 matching was performed to create similar exposure groups for analysis. Outcome measures of interest included: primary patency, freedom from major adverse limb events (MALEs), and amputation free survival at 1 year as a function of vein patch utilization. Time to event data were compared with the log-rank test; multivariable Cox proportional hazard models were used to evaluate the adjusted association between vein cuff usage and the primary end points. DVA was defined as a vein patch, cuff, or boot in any configuration. Of the 1018 bypass operations, 94 (9.2%) had a DVA whereas 924 (90.8%) did not (no DVA). After propensity score matching, 88 DVAs (25%) and 264 no DVAs (75%) were analyzed. On univariate analysis of the matched cohort, the DVA and no DVA groups were similar in terms of mean age (70.0 vs 69.0; P = .55), male sex (58.0% vs 58.3%; P > .99), and preoperative characteristics such as living at home (93.2% vs 94.3%; P = .79) and independent ambulatory status (72.7% vs 75.7%; P = .64). The DVA and no DVA groups had similar rates of major comorbidities such as hypertension chronic obstructive pulmonary disease, diabetes mellitus, coronary artery disease, and dialysis dependence (P > .05 for all). Likewise, they had similar rates of distal origin grafts (13.6% vs 12.5%; P = .85), critical limb ischemia indications (P = .53), and prior arterial bypass (58% vs 47%; P = .08

  20. A radiograph positioning technique to evaluate prosthetic misfit and bone loss around implants.

    PubMed

    Lin, Kevin C; Wadhwani, Chandur P K; Sharma, Arun; Finzen, Frederick

    2014-02-01

    A radiograph positioning device was developed to fit with commercially available film holders and implant systems. The device is indexed to the dental implant body and the adjacent dentition by using an implant placement driver and polyvinyl siloxane occlusal registration material. By fitting the device to a conventional film holder, accurate orthogonal radiographs can monitor changes in bone architecture and prosthetic misfit. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  1. Predictors of Success on the Prosthetics Certification Examination

    ERIC Educational Resources Information Center

    Miro, Rebecca Maria

    2014-01-01

    Students who graduate from a practitioner program in prosthetics & orthotics must achieve certification in order to obtain licensure and practice independently in 16 states. In states where licensure is not mandatory, graduates may choose to pursue certification in order assure patients that they are practicing at the highest level as well as…

  2. Surface EMG and intra-socket force measurement to control a prosthetic device

    NASA Astrophysics Data System (ADS)

    Sanford, Joe; Patterson, Rita; Popa, Dan

    2015-06-01

    Surface electromyography (SEMG) has been shown to be a robust and reliable interaction method allowing for basic control of powered prosthetic devices. Research has shown a marked decrease in EMG-classification efficiency throughout activities of daily life due to socket shift and movement and fatigue as well as changes in degree of fit of the socket throughout the subject's lifetime. Users with the most severe levels of amputation require the most complex devices with the greatest number of degrees of freedom. Controlling complex dexterous devices with limited available inputs requires the addition of sensing and interaction modalities. However, the larger the amputation severity, the fewer viable SEMG sites are available as control inputs. Previous work reported the use of intra-socket pressure, as measured during wrist flexion and extension, and has shown that it is possible to control a powered prosthetic device with pressure sensors. In this paper, we present data correlations of SEMG data with intra-socket pressure data. Surface EMG sensors and force sensors were housed within a simulated prosthetic cuff fit to a healthy-limbed subject. EMG and intra-socket force data was collected from inside the cuff as a subject performed pre-defined grip motions with their dominant hand. Data fusion algorithms were explored and allowed a subject to use both intra-socket pressure and SEMG data as control inputs for a powered prosthetic device. This additional input modality allows for an improvement in input classification as well as information regarding socket fit through out activities of daily life.

  3. Peri-prosthetic fractures around tumor endoprostheses: a retrospective analysis of eighteen cases.

    PubMed

    Barut, Nicolas; Anract, Philippe; Babinet, Antoine; Biau, David

    2015-09-01

    Tumour hip and knee endoprostheses have become the mainstay for reconstruction of patients with bone tumours. Fixation into host bone has improved over time. However, some patients present with a peri-prosthetic fracture over follow-up. The objective of this study was to analyse the mode of presentation and survival of implant after a peri-prosthetic fracture around a tumour endoprosthesis. Eighteen peri-prosthetic fractures (17 patients) were included. All patients were treated at a tertiary care center. There were 11 (65%) women; the median age at the time of fracture was 38 years old. All implants were cemented and all knee endoprostheses were fixed-hinge. Twelve (67%) fractures occurred after femoral resection and six (33%) fractures after proximal tibial resection. There were three femoral neck fractures (UCS C), three femoral shaft type C fractures, two femoral shaft type B1, one tibial shaft type B2, three tibial shaft type C, three ankle fractures (UCS C) and three patella fractures (UCS F). Two fractures were treated conservatively and 16 were operated on. Only one patient had the implant revised. There were eight (44%) failures over follow-up; none of the conservative treatment failed. The cumulative probability of failure for any reason was 27% (8-52) and 55% (22-79) at five and ten years, respectively. Peri-prosthetic fractures around massive endoprostheses are different from that of standard implants. There are more type C fractures; internal fixation is an attractive option at the time of presentation but the risk of revision over follow-up is high and patients should be informed accordingly.

  4. Rapid prototyping prosthetic hand acting by a low-cost shape-memory-alloy actuator.

    PubMed

    Soriano-Heras, Enrique; Blaya-Haro, Fernando; Molino, Carlos; de Agustín Del Burgo, José María

    2018-06-01

    The purpose of this article is to develop a new concept of modular and operative prosthetic hand based on rapid prototyping and a novel shape-memory-alloy (SMA) actuator, thus minimizing the manufacturing costs. An underactuated mechanism was needed for the design of the prosthesis to use only one input source. Taking into account the state of the art, an underactuated mechanism prosthetic hand was chosen so as to implement the modifications required for including the external SMA actuator. A modular design of a new prosthesis was developed which incorporated a novel SMA actuator for the index finger movement. The primary objective of the prosthesis is achieved, obtaining a modular and functional low-cost prosthesis based on additive manufacturing executed by a novel SMA actuator. The external SMA actuator provides a modular system which allows implementing it in different systems. This paper combines rapid prototyping and a novel SMA actuator to develop a new concept of modular and operative low-cost prosthetic hand.

  5. Illusory movement perception improves motor control for prosthetic hands

    PubMed Central

    Marasco, Paul D.; Hebert, Jacqueline S.; Sensinger, Jon W.; Shell, Courtney E.; Schofield, Jonathon S.; Thumser, Zachary C.; Nataraj, Raviraj; Beckler, Dylan T.; Dawson, Michael R.; Blustein, Dan H.; Gill, Satinder; Mensh, Brett D.; Granja-Vazquez, Rafael; Newcomb, Madeline D.; Carey, Jason P.; Orzell, Beth M.

    2018-01-01

    To effortlessly complete an intentional movement, the brain needs feedback from the body regarding the movement’s progress. This largely non-conscious kinesthetic sense helps the brain to learn relationships between motor commands and outcomes to correct movement errors. Prosthetic systems for restoring function have predominantly focused on controlling motorized joint movement. Without the kinesthetic sense, however, these devices do not become intuitively controllable. Here we report a method for endowing human amputees with a kinesthetic perception of dexterous robotic hands. Vibrating the muscles used for prosthetic control via a neural-machine interface produced the illusory perception of complex grip movements. Within minutes, three amputees integrated this kinesthetic feedback and improved movement control. Combining intent, kinesthesia, and vision instilled participants with a sense of agency over the robotic movements. This feedback approach for closed-loop control opens a pathway to seamless integration of minds and machines. PMID:29540617

  6. Effect of retorque on loosening torque of prosthetic screws under two levels of fit of implant-supported dentures.

    PubMed

    Spazzin, Aloísio Oro; Henrique, Guilherme Elias Pessanha; Nóbilo, Mauro Antônio de Arruda; Consani, Rafael Leonardo Xediek; Correr-Sobrinho, Lourenço; Mesquita, Marcelo Ferraz

    2010-01-01

    This study evaluated the influence of retorque on loosening torque (Lt) of prosthetic screws in implant-supported dentures with different fit levels. Ten mandibular implant-supported dentures were fabricated and then 20 cast models were then prepared using prosthetic structures to create 2 fit levels: passive fit (Pf) and misfit (Mf). Two tightening techniques were also evaluated: initial torque only (T1); and initial torque and retorque after 10 min (T2). Gold or titanium screws were used, resulting in 4 groups to each one: Pf/T1, Pf/T2, Mf/T1, Mf/T2. The Lt was measured 24 h after the tightening torque using digital torque meter. Data were analyzed statistically by two-way ANOVA and Tukey's test (alpha=0.05), separately for each screw material. For titanium screws, no significant difference (p>0.05) was found between Pf/T1 and Pf/T2, or between Pf/T2 and Mf/T2. However, statistically significant difference (p<0.05) was found between Pf/T1 and Mf/T1, and between Mf/T1 and Mf/T2. Mf reduced the Lt using T1, while and T2 increased the Lt for Mf. Retorque and fit were shown to have no significant influence on the Lt of the gold screws. Retorque application made insignificant the misfit effect on the Lt of the titanium screws, suggesting that this procedure should be performed routinely during the screw tightening in multi-unit dentures.

  7. Red flag in the emergency department: fracture and primary failure of a prosthetic valve.

    PubMed

    Ozsarac, Murat; Karcioglu, Ozgur; Ayrik, Cuneyt; Bozkurt, Seyran; Turkcuer, Ibrahim; Gumrukcu, Serhat

    2005-07-01

    This case report concerns a patient with fracture and primary dysfunction of a prosthetic valve. A 40-year-old man presented to the Emergency Department with a chief complaint of breakthrough pleuritic back pain and shortness of breath. Past surgical history was significant only for an aortic valve replacement and mitral valve replacement performed 16 years prior. The transthoracic echocardiography raised suspicion of prosthesis malposition. The patient was taken to the operating room by cardiothoracic surgeons for valve replacement. Operative findings revealed that a prosthetic valve leaflet in the mitral position had broken off. Primary prosthetic valve failure should not be overlooked in the differential diagnosis of patients with valve replacement and a rapidly deteriorating clinical course. Emergency echocardiography is a guide to convenient diagnosis and management. Early surgical consultation and early reparative surgery might prevent unnecessary morbidity and mortality.

  8. Development of Standardized Material Testing Protocols for Prosthetic Liners

    PubMed Central

    Cagle, John C.; Reinhall, Per G.; Hafner, Brian J.; Sanders, Joan E.

    2017-01-01

    A set of protocols was created to characterize prosthetic liners across six clinically relevant material properties. Properties included compressive elasticity, shear elasticity, tensile elasticity, volumetric elasticity, coefficient of friction (CoF), and thermal conductivity. Eighteen prosthetic liners representing the diverse range of commercial products were evaluated to create test procedures that maximized repeatability, minimized error, and provided clinically meaningful results. Shear and tensile elasticity test designs were augmented with finite element analysis (FEA) to optimize specimen geometries. Results showed that because of the wide range of available liner products, the compressive elasticity and tensile elasticity tests required two test maxima; samples were tested until they met either a strain-based or a stress-based maximum, whichever was reached first. The shear and tensile elasticity tests required that no cyclic conditioning be conducted because of limited endurance of the mounting adhesive with some liner materials. The coefficient of friction test was based on dynamic coefficient of friction, as it proved to be a more reliable measurement than static coefficient of friction. The volumetric elasticity test required that air be released beneath samples in the test chamber before testing. The thermal conductivity test best reflected the clinical environment when thermal grease was omitted and when liner samples were placed under pressure consistent with load bearing conditions. The developed procedures provide a standardized approach for evaluating liner products in the prosthetics industry. Test results can be used to improve clinical selection of liners for individual patients and guide development of new liner products. PMID:28233885

  9. Factors associated with tooth loss and prosthodontic status among Sudanese adults.

    PubMed

    Khalifa, Nadia; Allen, Patrick F; Abu-bakr, Neamat H; Abdel-Rahman, Manar E

    2012-01-01

    A study was conducted to determine the degree of tooth loss, factors influencing tooth loss, and the extent of prosthodontic rehabilitation in Sudanese adults (≥ 16 years old) attending outpatient clinics in Khartoum State. Pearson and multivariate analyses were used to examine the relationships between tooth loss and specific characteristics determined through interviews and clinical examinations. The mean number of missing teeth was 3.6 (SD, 4.9) and the prevalence of edentulism was 0.1%. The prevalence of tooth loss (missing at least one tooth) was 78%; 66.9% of tooth loss was due to caries, and 11.2% was attributable to other reasons. Prosthetic replacement of missing teeth was evident in 3%, whereas a need for prosthetic replacement was evident in 57%. Having < 20 teeth was associated with age, gender, and socioeconomic status; tooth loss due to caries was associated with age, tribe, frequency of tooth-brushing, and a low rate of dental consultation. Tooth loss due to other reasons was associated with age, tribe, education, periodontal pocketing, tobacco use, tooth wear, and prosthetic status. The results of the present study indicated that the major cause of tooth loss was dental caries, thus emphasizing the importance of a public prevention-based healthcare program. Replacement of missing teeth was uncommon in the study subjects, which may reflect lack of access to this type of oral healthcare.

  10. The importance of aerodynamics for prosthetic limb design used by competitive cyclists with an amputation: An introduction.

    PubMed

    Dyer, Bryce

    2015-06-01

    This study introduces the importance of the aerodynamics to prosthetic limb design for athletes with either a lower-limb or upper-limb amputation. The study comprises two elements: 1) An initial experiment investigating the stability of outdoor velodrome-based field tests, and 2) An experiment evaluating the application of outdoor velodrome aerodynamic field tests to detect small-scale changes in aerodynamic drag respective of prosthetic limb componentry changes. An outdoor field-testing method is used to detect small and repeatable changes in the aerodynamic drag of an able-bodied cyclist. These changes were made at levels typical of alterations in prosthetic componentry. The field-based test method of assessment is used at a smaller level of resolution than previously reported. With a carefully applied protocol, the field test method proved to be statistically stable. The results of the field test experiments demonstrate a noticeable change in overall athlete performance. Aerodynamic refinement of artificial limbs is worthwhile for athletes looking to maximise their competitive performance. A field-testing method illustrates the importance of the aerodynamic optimisation of prosthetic limb components. The field-testing protocol undertaken in this study gives an accessible and affordable means of doing so by prosthetists and sports engineers. Using simple and accessible field-testing methods, this exploratory experiment demonstrates how small changes to riders' equipment, consummate of the scale of a small change in prosthetics componentry, can affect the performance of an athlete. Prosthetists should consider such opportunities for performance enhancement when possible. © The International Society for Prosthetics and Orthotics 2014.

  11. Ureaplasma parvum prosthetic joint infection detected by PCR.

    PubMed

    Farrell, John J; Larson, Joshua A; Akeson, Jeffrey W; Lowery, Kristin S; Rounds, Megan A; Sampath, Rangarajan; Bonomo, Robert A; Patel, Robin

    2014-06-01

    We describe the first reported case of Ureaplasma parvum prosthetic joint infection (PJI) detected by PCR. Ureaplasma species do not possess a cell wall and are usually associated with colonization and infection of mucosal surfaces (not prosthetic material). U. parvum is a relatively new species name for certain serovars of Ureaplasma urealyticum, and PCR is useful for species determination. Our patient presented with late infection of his right total knee arthroplasty. Intraoperative fluid and tissue cultures and pre- and postoperative synovial fluid cultures were all negative. To discern the pathogen, we employed PCR coupled with electrospray ionization mass spectrometry (PCR/ESI-MS). Our patient's failure to respond to empirical antimicrobial treatment and our previous experience with PCR/ESI-MS in culture-negative cases of infection prompted us to use this approach over other diagnostic modalities. PCR/ESI-MS detected U. parvum in all samples. U. parvum-specific PCR testing was performed on all synovial fluid samples to confirm the U. parvum detection. Copyright © 2014, American Society for Microbiology. All Rights Reserved.

  12. Quantifying prosthetic gait deviation using simple outcome measures

    PubMed Central

    Kark, Lauren; Odell, Ross; McIntosh, Andrew S; Simmons, Anne

    2016-01-01

    AIM: To develop a subset of simple outcome measures to quantify prosthetic gait deviation without needing three-dimensional gait analysis (3DGA). METHODS: Eight unilateral, transfemoral amputees and 12 unilateral, transtibial amputees were recruited. Twenty-eight able-bodied controls were recruited. All participants underwent 3DGA, the timed-up-and-go test and the six-minute walk test (6MWT). The lower-limb amputees also completed the Prosthesis Evaluation Questionnaire. Results from 3DGA were summarised using the gait deviation index (GDI), which was subsequently regressed, using stepwise regression, against the other measures. RESULTS: Step-length (SL), self-selected walking speed (SSWS) and the distance walked during the 6MWT (6MWD) were significantly correlated with GDI. The 6MWD was the strongest, single predictor of the GDI, followed by SL and SSWS. The predictive ability of the regression equations were improved following inclusion of self-report data related to mobility and prosthetic utility. CONCLUSION: This study offers a practicable alternative to quantifying kinematic deviation without the need to conduct complete 3DGA. PMID:27335814

  13. Factors That Influence Language Growth.

    ERIC Educational Resources Information Center

    McCarthy, Dorothea, Ed.; And Others

    This booklet contains four articles that discuss factors influencing language growth. The first, "The Child's Equipment for Language Growth" by Charlotte Wells, examines what the child needs for language learning, how the child uses his equipment for language growth, and what school factors facilitate the child's use of his equipment for language…

  14. Current standard rules of combined anteversion prevent prosthetic impingement but ignore osseous contact in total hip arthroplasty.

    PubMed

    Weber, Markus; Woerner, Michael; Craiovan, Benjamin; Voellner, Florian; Worlicek, Michael; Springorum, Hans-Robert; Grifka, Joachim; Renkawitz, Tobias

    2016-12-01

    In this prospective study of 135 patients undergoing cementless total hip arthroplasty (THA) we asked whether six current definitions of combined anteversion prevent impingement and increase postoperative patient individual impingement-free range-of-motion (ROM). Implant position was measured by an independent, external institute on 3D-CT performed six weeks post-operatively. Post-operative ROM was calculated using a CT-based algorithm detecting osseous and/or prosthetic impingement by virtual hip movement. Additionally, clinical ROM was evaluated pre-operatively and one-year post-operatively by a blinded observer. Combined component position of cup and stem according to the definitions of Ranawat, Widmer, Dorr, Hisatome and Yoshimine inhibited prosthetic impingement in over 90 %, while combined osseous and prosthetic impingement still occurred in over 40 % of the cases. The recommendations by Jolles, Widmer, Dorr, Yoshimine and Hisatome enabled higher flexion (p ≤ 0.001) and internal rotation (p ≤ 0.006). Clinically, anteversion rules of Widmer and Yoshimine provided one-year post-operatively statistically but not clinically relevant higher internal rotation (p ≤0.034). Standard rules of combined anteversion detect prosthetic but fail to prevent combined osseous and prosthetic impingement in THA. Future models will have to account for the patient-individual anatomic situation to ensure impingement-free ROM.

  15. Introduction to the Centers for Disease Control and Prevention and Healthcare Infection Control Practices Advisory Committee Guideline for Prevention of Surgical Site Infection: Prosthetic Joint Arthroplasty Section.

    PubMed

    Segreti, John; Parvizi, Javad; Berbari, Elie; Ricks, Philip; Berríos-Torres, Sandra I

    Peri-prosthetic joint infection (PJI) is a severe complication of total joint arthroplasty that appears to be increasing as more of these procedures are performed. Numerous risk factors for incisional (superficial and deep) and organ/space (e.g., PJI) surgical site infections (SSIs) have been identified. A better understanding and reversal of modifiable risk factors may lead to a reduction in the incidence of incisional SSI and PJI. The Centers for Disease Control and Prevention (CDC) and the Healthcare Infection Control Practices Advisory Committee (HICPAC) recently updated the national Guideline for Prevention of Surgical Site Infection. The updated guideline applies evidence-based methodology, presents recommendations for potential strategies to reduce the risk of SSI, and includes an arthroplasty-specific section. This article serves to introduce the guideline development process and to complement the Prosthetic Joint Arthroplasty section with background information on PJI-specific economic burden, epidemiology, pathogenesis and microbiology, and risk factor information.

  16. Factors influencing children's food choice.

    PubMed

    Koivisto Hursti, U K

    1999-04-01

    Although food habits are not stable and unchanging during a person's lifetime, a base for healthy food habits can be created in early childhood. Children's food habits can be assumed to be influenced by their parents' food habits and choices. The aim of this article is to review factors influencing food choice in children as well as in adults. The results demonstrate that the development of children's food habits is influenced by a multitude of factors. Parents play an important role in the formation of food habits and preferences of young children. They can influence their children's food choice by making specific foods available, by acting as models for their children and by their behaviour in specific situations. Children tend to be afraid of new foods and do not readily accept them. However, experience is known to enhance preference, and earlier experiences of a particular food are the major determinants of the development of children's food acceptance patterns. Thus, parents should be encouraged to make healthy foods easily available to the child and serve these foods in positive mealtime situations in order to help their child to develop healthy food habits.

  17. Factors influencing children's food choice.

    PubMed

    Hursti, Ulla-Kaisa Koivisto

    1999-01-01

    Although food habits arc not stable and unchanging during a person's lifetime, a base for healthy food habits can be created in early childhood. Children's food habits can be assumed to be influenced by their parents' food habits and choices. The aim of this article is to review factors influencing food choice in children as well as in adults. The results demonstrate that the development of children's food habits is influenced by a multitude of factors. Parents play an important role in the formation of food habits and preferences of young children. They can influence their children's food choice by making specific foods available, by acting as models for their children and by their behaviour in specific situations. Children tend to be afraid of new foods and do not readily accept them. However, experience is known to enhance preference, and earlier experiences of a particular food are the major determinants of the development of children's food acceptance patterns. Thus, parents should be encouraged to make healthy foods easily available to the child and serve these foods in positive mealtime situations in order to help their child to develop healthy food habits.

  18. Prosthetic Aortic Valve Fixation Study: 48 Replacement Valves Analyzed Using Digital Pressure Mapping.

    PubMed

    Lee, Candice Y; Wong, Joshua K; Ross, Ronald E; Liu, David C; Khabbaz, Kamal R; Martellaro, Angelo J; Gorea, Heather R; Sauer, Jude S; Knight, Peter A

    Prostheses attachment is critical in aortic valve replacement surgery, yet reliable prosthetic security remains a challenge. Accurate techniques to analyze prosthetic fixation pressures may enable the use of fewer sutures while reducing the risk of paravalvular leaks (PVL). Customized digital thin film pressure transducers were sutured between aortic annulus models and 21-mm bioprosthetic valves with 15 × 4-mm, 12 × 4-mm, or 9 × 6-mm-wide pledgeted mattress sutures. Simulating open and minimally invasive access, 4 surgeons, blinded to data acquisition, each secured 12 valves using manual knot-tying (hand-tied [HT] or knot-pusher [KP]) or automated titanium fasteners (TFs). Real-time pressure measurements and times were recorded. Two-dimensional (2D) and 3D pressure maps were generated for all valves. Pressures less than 80 mm Hg were considered at risk for PVL. Pressures under each knot (intrasuture) fell less than 80 mm Hg for 12 of 144 manual knots (5/144 HT, 7/144 KP) versus 0 of 288 TF (P < 0.001). Pressures outside adjacent sutures (extrasuture) were less than 80 mm Hg in 10 of 60 HT, zero of 60 KP, and zero of 120 TF sites for 15 × 4-mm valves; 17 of 48 HT, 25 of 48 KP, and 12 of 96 TF for 12 × 4-mm valves; and 15 of 36 HT, 17 of 36 KP, and 9 and 72 TF for 9 × 6-mm valves; P < 0.001 all manual versus TF. Annular areas with pressures less than 80 mm Hg ranged from 0% of the sewing-ring area (all open TF) to 31% (12 × 4 mm, KP). The average time per manual knot, 46 seconds (HT, 31 seconds; KP, 61 seconds), was greater than TF, 14 seconds (P < 0.005). Reduced operative times and PVL risk would fortify the advantages of surgical aortic valve replacement. This research encourages continued exploration of technical factors in optimizing prosthetic valve security.

  19. Corynebacterium minutissimum vascular graft infection: case report and review of 281 cases of prosthetic device-related Corynebacterium infection.

    PubMed

    Reece, Rebecca M; Cunha, Cheston B; Rich, Josiah D

    2014-09-01

    Corynebacterium spp. have proven their pathogenic potential in causing infections, particularly in the setting of immunosuppression and prosthetic devices. We conducted a PubMed literature review of all cases of Corynebacterium prosthetic device infections published in the English language through December 2013. The majority of cases involved peritoneal dialysis and central venous catheters, but prosthetic joints and central nervous system shunts/drains were also involved. The management of these cases in terms of retention or removal of the device was not uniform; however, the overall mortality remained the same among both groups. All of these prosthetic device infections pose potential problems in management when the device cannot be removed safely for the patient, especially with the lack of data on the pathogenicity of Corynebacterium species. However with better identification of species and sensitivities, successful treatment is possible even with retention of the device.

  20. A rare case of prosthetic endocarditis and dehiscence in a mechanical valved conduit

    PubMed Central

    Kannan, Arun; Smith, Cristy; Subramanian, Sreekumar; Janardhanan, Rajesh

    2014-01-01

    A middle-aged adult patient with a history of aortic root replacement with a mechanical valved conduit and remote chest trauma was referred to our institution with prosthetic endocarditis. Transoesophageal echocardiogram at our institution confirmed a near-complete dehiscence of the prosthetic aortic valve from the conduit, with significant perivalvular flow forming a pseudoaneurysm. The patient underwent a high-risk re-operation, involving redo aortic root replacement with a homograft after extensive debridement of the infected tissue. The patient was discharged to an outside facility after an uncomplicated hospital course, and remains stable. PMID:24510692

  1. A rare case of prosthetic endocarditis and dehiscence in a mechanical valved conduit.

    PubMed

    Kannan, Arun; Smith, Cristy; Subramanian, Sreekumar; Janardhanan, Rajesh

    2014-02-07

    A middle-aged adult patient with a history of aortic root replacement with a mechanical valved conduit and remote chest trauma was referred to our institution with prosthetic endocarditis. Transoesophageal echocardiogram at our institution confirmed a near-complete dehiscence of the prosthetic aortic valve from the conduit, with significant perivalvular flow forming a pseudoaneurysm. The patient underwent a high-risk re-operation, involving redo aortic root replacement with a homograft after extensive debridement of the infected tissue. The patient was discharged to an outside facility after an uncomplicated hospital course, and remains stable.

  2. Prevention of Propionibacterium acnes biofilm formation in prosthetic infections in vitro.

    PubMed

    Howlin, Robert P; Winnard, Christopher; Angus, Elizabeth M; Frapwell, Connor J; Webb, Jeremy S; Cooper, John J; Aiken, Sean S; Bishop, Julie Y; Stoodley, Paul

    2017-04-01

    The role of Propionibacterium acnes in shoulder arthroplasty and broadly in orthopedic prosthetic infections has historically been underestimated, with biofilm formation identified as a key virulence factor attributed to invasive isolates. With an often indolent clinical course, P acnes infection can be difficult to detect and treat. This study investigates absorbable cements loaded with a broad-spectrum antibiotic combination as an effective preventive strategy to combat P acnes biofilms. P acnes biofilm formation on an unloaded synthetic calcium sulfate (CaSO 4 ) bone void filler cement bead was evaluated by scanning electron microscopy over a period of 14 days. Beads loaded with tobramycin alone or vancomycin alone (as comparative controls) and beads loaded with a vancomycin-tobramycin dual treatment were assessed for their ability to eradicate planktonic P acnes, prevent biofilm formation, and eradicate preformed biofilms using a combination of viable-cell counts, confocal microscopy, and scanning electron microscopy. P acnes surface colonization and biofilm formation on unloaded CaSO 4 beads was slow. Beads loaded with antibiotics were able to kill planktonic cultures of 10 6  colony-forming units/mL, prevent bacterial colonization, and significantly reduce biofilm formation over periods of weeks. Complete eradication of established biofilms was achieved with a contact time of 1 week. This study demonstrates that antibiotic-loaded CaSO 4 beads may represent an effective antibacterial and antibiofilm strategy to combat prosthetic infections in which P acnes is involved. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  3. Using computed tomography and 3D printing to construct custom prosthetics attachments and devices.

    PubMed

    Liacouras, Peter C; Sahajwalla, Divya; Beachler, Mark D; Sleeman, Todd; Ho, Vincent B; Lichtenberger, John P

    2017-01-01

    The prosthetic devices the military uses to restore function and mobility to our wounded warriors are highly advanced, and in many instances not publically available. There is considerable research aimed at this population of young patients who are extremely active and desire to take part in numerous complex activities. While prosthetists design and manufacture numerous devices with standard materials and limb assemblies, patients often require individualized prosthetic design and/or modifications to enable them to participate fully in complex activities. Prosthetists and engineers perform research and implement digitally designs in collaboration to generate equipment for their patient's rehabilitation needs. 3D printing allows for these devices to be manufactured from an array of materials ranging from plastic to titanium alloy. Many designs require form fitting to a prosthetic socket or a complex surface geometry. Specialty items can be scanned using computed tomography and digitally reconstructed to produce a virtual 3D model the engineer can use to design the necessary features of the desired prosthetic, device, or attachment. Completed devices are tested for fit and function. Numerous custom prostheses and attachments have been successfully translated from the research domain to clinical reality, in particular, those that feature the use of computed tomography (CT) reconstructions. The purpose of this project is to describe the research pathways to implementation for the following clinical designs: sets of bilateral hockey skates; custom weightlifting prosthetic hands; and a wine glass holder. This article will demonstrate how to incorporate CT imaging and 3D printing in the design and manufacturing process of custom attachments and assistive technology devices. Even though some of these prosthesis attachments may be relatively simple in design to an engineer, they have an enormous impact on the lives of our wounded warriors.

  4. A systematic review of randomised controlled trials assessing effectiveness of prosthetic and orthotic interventions

    PubMed Central

    Farmer, Sybil; Pandyan, Anand; Chockalingam, Nachiappan

    2018-01-01

    Background Assistive products are items which allow older people and people with disabilities to be able to live a healthy, productive and dignified life. It has been estimated that approximately 1.5% of the world’s population need a prosthesis or orthosis. Objective The objective of this study was to systematically identify and review the evidence from randomized controlled trials assessing effectiveness and cost-effectiveness of prosthetic and orthotic interventions. Methods Literature searches, completed in September 2015, were carried out in fourteen databases between years 1995 and 2015. The search results were independently screened by two reviewers. For the purpose of this manuscript, only randomized controlled trials which examined interventions using orthotic or prosthetic devices were selected for data extraction and synthesis. Results A total of 342 randomised controlled trials were identified (319 English language and 23 non-English language). Only 4 of these randomised controlled trials examined prosthetic interventions and the rest examined orthotic interventions. These orthotic interventions were categorised based on the medical conditions/injuries of the participants. From these studies, this review focused on the medical condition/injuries with the highest number of randomised controlled trials (osteoarthritis, fracture, stroke, carpal tunnel syndrome, plantar fasciitis, anterior cruciate ligament, diabetic foot, rheumatoid and juvenile idiopathic arthritis, ankle sprain, cerebral palsy, lateral epicondylitis and low back pain). The included articles were assessed for risk of bias using the Cochrane Risk of Bias tool. Details of the clinical population examined, the type of orthotic/prosthetic intervention, the comparator/s and the outcome measures were extracted. Effect sizes and odds ratios were calculated for all outcome measures, where possible. Conclusions At present, for prosthetic and orthotic interventions, the scientific literature does

  5. Prosthetic valve endocarditis: early and late outcome following medical or surgical treatment

    PubMed Central

    Akowuah, E F; Davies, W; Oliver, S; Stephens, J; Riaz, I; Zadik, P; Cooper, G

    2003-01-01

    Objective: To compare the early and late outcome of medical and surgical treatment in patients with prosthetic valve endocarditis within a single unit. Design: All patients with proven prosthetic valve endocarditis treated in one institution between 1989 and 1999 were studied. Results: There were 66 patients (24 female, 42 male), mean (SD) age 57 (14) years. Of these, 28 were treated with antibiotics alone and 38 with a combination of antibiotics and surgery. The in-hospital mortality for the antibiotic group was 46% and for the surgical group, 24%. However, seven patients in the antibiotic group were considered too sick for curative treatment. The mortality in the remaining 21 medically treated patients (6/21; 29%) was not significantly different from that in the surgically treated patients (p = 0.15). Six patients in the medically treated group and one in the surgically treated group required late reoperation. Endocarditis recurred in three patients in the medically treated group, two of whom were treated surgically, and in one patient in the surgically treated group. Kaplan–Meier survival at 10 years was 28% in the medically treated group v 58% in the surgically treated group (p = 0.04). Freedom from endocarditis at five years was 60% in the surgically treated group and 65% in the medically treated group. Conclusions: Prosthetic valve endocarditis is a serious condition with high early and late mortality, irrespective of the treatment employed. These data show that selected patients with prosthetic valve endocarditis can be successfully treated with antibiotics alone. If required, surgery in this difficult group of patients can provide satisfactory freedom from recurrent infection. PMID:12591827

  6. Automated hexahedral mesh generation from biomedical image data: applications in limb prosthetics.

    PubMed

    Zachariah, S G; Sanders, J E; Turkiyyah, G M

    1996-06-01

    A general method to generate hexahedral meshes for finite element analysis of residual limbs and similar biomedical geometries is presented. The method utilizes skeleton-based subdivision of cross-sectional domains to produce simple subdomains in which structured meshes are easily generated. Application to a below-knee residual limb and external prosthetic socket is described. The residual limb was modeled as consisting of bones, soft tissue, and skin. The prosthetic socket model comprised a socket wall with an inner liner. The geometries of these structures were defined using axial cross-sectional contour data from X-ray computed tomography, optical scanning, and mechanical surface digitization. A tubular surface representation, using B-splines to define the directrix and generator, is shown to be convenient for definition of the structure geometries. Conversion of cross-sectional data to the compact tubular surface representation is direct, and the analytical representation simplifies geometric querying and numerical optimization within the mesh generation algorithms. The element meshes remain geometrically accurate since boundary nodes are constrained to lie on the tubular surfaces. Several element meshes of increasing mesh density were generated for two residual limbs and prosthetic sockets. Convergence testing demonstrated that approximately 19 elements are required along a circumference of the residual limb surface for a simple linear elastic model. A model with the fibula absent compared with the same geometry with the fibula present showed differences suggesting higher distal stresses in the absence of the fibula. Automated hexahedral mesh generation algorithms for sliced data represent an advancement in prosthetic stress analysis since they allow rapid modeling of any given residual limb and optimization of mesh parameters.

  7. Prosthetic metal implants and airport metal detectors.

    PubMed

    Ismail, A; Dancey, A; Titley, O G

    2013-04-01

    Metal detectors have been present in airports and points of departure for some time. With the introduction of heightened security measures in response to fears of an increased threat of terrorism, they may become more prevalent in other public locations. The aim of this study was to ascertain which prosthetic devices activated metal detector devices used for security purposes. A range of prosthetic devices used commonly in orthopaedic and plastic surgery procedures were passed through an arch metal detector at Birmingham Airport in the UK. Additionally, each item was passed under a wand detector. Items tested included expandable breast prostheses, plates used in wrist and hand surgery, screws, K-wires, Autosuture™ ligation clips and staples. No prostheses were detected by the arch detector. The expandable implants and wrist plates were the only devices detected by passing the wand directly over them. No device was detected by the wand when it was under cover of the axillary soft tissue. Screws, K-wires, Autosuture™ clips and staples were not detected under any of the study conditions. Although unlikely to trigger a detector, it is possible that an expandable breast prosthesis or larger plate may do so. It is therefore best to warn patients of this so they can anticipate detection and further examination.

  8. Comparison of using different bridge prosthetic designs for partial defect restoration through mathematical modeling.

    PubMed

    Styranivska, Oksana; Kliuchkovska, Nataliia; Mykyyevych, Nataliya

    2017-01-01

    To analyze the stress-strain states of bone and abutment teeth during the use of different prosthetic designs of fixed partial dentures with the use of relevant mathematical modeling principles. The use of Comsol Multiphysics 3.5 (Comsol AB, Sweden) software during the mathematical modeling of stress-strain states provided numerical data for analytical interpretation in three different clinical scenarios with fixed dentures and different abutment teeth and demountable prosthetic denture with the saddle-shaped intermediate part. Microsoft Excel Software (Microsoft Office 2017) helped to evaluate absolute mistakes of stress and strain parameters of each abutment tooth during three modeled scenarios and normal condition and to summarize data into the forms of tables. In comparison with the fixed prosthetic denture supported by the canine, first premolar, and third molar, stresses at the same abutment teeth with the use of demountable denture with the saddle-shaped intermediate part decreased: at the mesial abutment tooth by 2.8 times, at distal crown by 6.1 times, and at the intermediate part by 11.1 times, respectively, the deformation level decreased by 3.1, 1.9, and 1.4 times at each area. The methods of mathematical modeling proved that complications during the use of fixed partial dentures based on the overload effect of the abutment teeth and caused by the deformation process inside the intermediate section of prosthetic construction.

  9. Fiber-array based optogenetic prosthetic system for stimulation therapy

    NASA Astrophysics Data System (ADS)

    Gu, Ling; Cote, Chris; Tejeda, Hector; Mohanty, Samarendra

    2012-02-01

    Recent advent of optogenetics has enabled activation of genetically-targeted neuronal cells using low intensity blue light with high temporal precision. Since blue light is attenuated rapidly due to scattering and absorption in neural tissue, optogenetic treatment of neurological disorders may require stimulation of specific cell types in multiple regions of the brain. Further, restoration of certain neural functions (vision, and auditory etc) requires accurate spatio-temporal stimulation patterns rather than just precise temporal stimulation. In order to activate multiple regions of the central nervous system in 3D, here, we report development of an optogenetic prosthetic comprising of array of fibers coupled to independently-controllable LEDs. This design avoids direct contact of LEDs with the brain tissue and thus does not require electrical and heat isolation, which can non-specifically stimulate and damage the local brain regions. The intensity, frequency, and duty cycle of light pulses from each fiber in the array was controlled independently using an inhouse developed LabView based program interfaced with a microcontroller driving the individual LEDs. While the temporal profile of the light pulses was controlled by varying the current driving the LED, the beam profile emanating from each fiber tip could be sculpted by microfabrication of the fiber tip. The fiber array was used to stimulate neurons, expressing channelrhodopsin-2, in different locations within the brain or retina. Control of neural activity in the mice cortex, using the fiber-array based prosthetic, is evaluated from recordings made with multi-electrode array (MEA). We also report construction of a μLED array based prosthetic for spatio-temporal stimulation of cortex.

  10. Prosthetic component segmentation with blur compensation: a fast method for 3D fluoroscopy.

    PubMed

    Tarroni, Giacomo; Tersi, Luca; Corsi, Cristiana; Stagni, Rita

    2012-06-01

    A new method for prosthetic component segmentation from fluoroscopic images is presented. The hybrid approach we propose combines diffusion filtering, region growing and level-set techniques without exploiting any a priori knowledge of the analyzed geometry. The method was evaluated on a synthetic dataset including 270 images of knee and hip prosthesis merged to real fluoroscopic data simulating different conditions of blurring and illumination gradient. The performance of the method was assessed by comparing estimated contours to references using different metrics. Results showed that the segmentation procedure is fast, accurate, independent on the operator as well as on the specific geometrical characteristics of the prosthetic component, and able to compensate for amount of blurring and illumination gradient. Importantly, the method allows a strong reduction of required user interaction time when compared to traditional segmentation techniques. Its effectiveness and robustness in different image conditions, together with simplicity and fast implementation, make this prosthetic component segmentation procedure promising and suitable for multiple clinical applications including assessment of in vivo joint kinematics in a variety of cases.

  11. [Results of usage of temporary prosthetics in cases of combat injuries of extremities].

    PubMed

    Samokhvalov, I M; Zavrazhanov, A A; Kornilov, E A

    2006-09-01

    The comparative analyzes of the results of usage of temporary prosthetics (TP) of injured main arteries during the war in Afghanistan (1979-1989) and counter-terrorist operations in the Northern Caucasus (1994-1996, 1999-2002) has been carried out. The development of new models of temporary prosthetics of vessels has been experimentally substantiated. In Afghanistan the two-staged usage of TP was made along with the amputation of extremities in 35,1% of cases and in the Northern Caucasus - in 15,0%. The reason for that was the considerable reduction of terms of evacuation of wounded. The average terms of presence of TP in the arteries in Afghanistan were 26,2+/-4,0 hours and in the Northern Caucasus - 18,1+/-3,4 hours. During a series of experiments on comparative testing of efficiency of three types of TP it was determined that prosthetics made of armored silicone (10,1+/-0,6 hours)and, especially made of enlarged micropored polytetraftoraethylen (11,5 +/-0,6 hours) are thrombosed slower comparing to polyclorvinil tube from the blood transfusion system (7,9+/-0,7 hours).

  12. May one-stage exchange for Candida albicans peri-prosthetic infection be successful?

    PubMed

    Jenny, J-Y; Goukodadja, O; Boeri, C; Gaudias, J

    2016-02-01

    Fungal infection of a total joint arthroplasty has a low incidence but is generally considered as more difficult to cure than bacterial infection. As for bacterial infection, two-stage exchange is considered as the gold standard of treatment. We report two cases of one-stage total joint exchange for fungal peri-prosthetic infection with Candida albicans, where the responsible pathogens was only identified on intraoperative samples. This situation can be considered as a one-stage exchange for fungal peri-prosthetic infection without preoperative identification of the responsible organism, which is considered as having a poor prognosis. Both cases were free of infection after two years. One-stage revision has several potential advantages over two-stage revision, including shorter hospital stay and rehabilitation, no interim period with significant functional impairment, shorter antibiotic treatment, better functional outcome and probably lower costs. We suggest that one-stage revision for C. albicans peri-prosthetic infection may be successful even without preoperative fungal identification. Level IV-Historical cases. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  13. Cognitive Neural Prosthetics

    PubMed Central

    Andersen, Richard A.; Hwang, Eun Jung; Mulliken, Grant H.

    2010-01-01

    The cognitive neural prosthetic (CNP) is a very versatile method for assisting paralyzed patients and patients with amputations. The CNP records the cognitive state of the subject, rather than signals strictly related to motor execution or sensation. We review a number of high-level cortical signals and their application for CNPs, including intention, motor imagery, decision making, forward estimation, executive function, attention, learning, and multi-effector movement planning. CNPs are defined by the cognitive function they extract, not the cortical region from which the signals are recorded. However, some cortical areas may be better than others for particular applications. Signals can also be extracted in parallel from multiple cortical areas using multiple implants, which in many circumstances can increase the range of applications of CNPs. The CNP approach relies on scientific understanding of the neural processes involved in cognition, and many of the decoding algorithms it uses also have parallels to underlying neural circuit functions. PMID:19575625

  14. Autologous alternative veins may not provide better outcomes than prosthetic conduits for below-knee bypass when great saphenous vein is unavailable.

    PubMed

    Avgerinos, Efthymios D; Sachdev, Ulka; Naddaf, Abdallah; Doucet, Dannielle R; Mohapatra, Abhisekh; Leers, Steven A; Chaer, Rabih A; Makaroun, Michel S

    2015-08-01

    There is a need to better define the role of alternative autologous vein (AAV) segments over contemporary prosthetic conduits in patients with critical limb ischemia when great saphenous vein (GSV) is not available for use as the bypass conduit. Consecutive patients who underwent bypass to infrageniculate targets between 2007 and 2011 were categorized in three groups: GSV, AAV, and prosthetic. The primary outcome was graft patency. The secondary outcome was limb salvage. Cox proportional hazards regression was used to adjust for baseline confounding variables. A total of 407 infrainguinal bypasses to below-knee targets were analyzed; 255 patients (63%) received a single-segment GSV, 106 patients (26%) received an AAV, and 46 patients (11%) received a prosthetic conduit. Baseline characteristics were similar among groups, with the exception of popliteal targets and anticoagulation use being more frequent in the prosthetic group. Primary patency at 2 and 5 years was estimated at 47% and 32%, respectively, for the GSV group; 24% and 23% for the AAV group; and 43% and 38% for the prosthetic group. Primary assisted patency at 2 and 5 years was estimated at 71% and 55%, respectively, for the GSV group; 53% and 51% for the AAV group; and 45% and 40% for the prosthetic group. Secondary patency at 2 and 5 years was estimated at 75% and 60%, respectively, for the GSV group; 57% and 55% for the AAV group; and 46% and 41% for the prosthetic group. In Cox analysis, primary patency (hazard ratio [HR], 0.55; P < .001; 95% confidence interval [CI], 0.404-0.758), primary assisted patency (HR, 0.57; P = .004; 95% CI, 0.388-0.831), and secondary patency (HR, 0.56; P = .005; 95% CI, 0.372-0.840) were predicted by GSV compared with AAV, but there was no difference between AAV and prosthetic grafts except for the primary patency, for which prosthetic was protective (HR, 0.38; P < .001; 95% CI, 0.224-0.629). Limb salvage was similar among groups. AAV conduits may not offer a significant

  15. Acute Mitral Valve Dysfunction Due to Escape of Prosthetic Mechanical Leaflet and Peripheral Leaftlet Embolization.

    PubMed

    Calik, Eyup Serhat; Limandal, Husnu Kamil; Arslan, Umit; Tort, Mehmet; Yildiz, Ziya; Bayram, Ednan; Dag, Ozgur; Kaygin, Mehmet Ali; Erkut, Bilgehan

    2015-12-14

    Leaflet escape of prosthetic valve is rare but potentially life threatening. Early diagnosis is essential on account of avoiding mortality, and emergency surgical correction is compulsory. This complication has previously been reported for both monoleaflet and bileaflet valve models. A 30-year-old man who had undergone mitral valve replacement with a bileaflet valve 8 years prior at another center was admitted with acute-onset with cardiogenic shock as an emergency case. Transthoracic echocardiograms showed acute-starting severe mitral regurgitation associated with prosthetic mitral valve. There was a suspicious finding of a single prosthetic mitral leaflet. But the problem related with the valve wasn't specifically determined. The patient underwent emergent surgery for replacement of the damaged prosthetic valves immediately. There was no tissue impingement and thrombosis, one of the two leaflets was absent, and there were no signs of endocarditis or pannus formation in the prosthetic valve. The missing leaflet could not be found within the cardiac cavity. The abdominal fluoroscopic study and plain radiography were unable to detect the escaped leaflet during surgery. The damaged valve was removed and a replacement 29 mm bileaflet mechanical valve was inserted by right lateral thoracotomy. After post-operative week one, the abdominal computed tomography scan and the ultrasound showed the escaped leaflet in the left femoral artery. Fifteen days after the surgery the escaped leaflet was removed safely from the left femoral artery and the patient made a complete recovery. The escaped leaflet showed a fracture of one of the pivot systems caused by structural failure. Early cardiac surgery should be applied because of life-threatening problems.

  16. Agreement between pre-operative and intra-operative bacteriological samples in 85 chronic peri-prosthetic infections.

    PubMed

    Matter-Parrat, V; Ronde-Oustau, C; Boéri, C; Gaudias, J; Jenny, J-Y

    2017-04-01

    Whether pre-operative microbiological sampling contributes to the management of chronic peri-prosthetic infection remains controversial. We assessed agreement between the results of pre-operative and intra-operative samples in patients undergoing single-stage prosthesis exchange to treat chronic peri-prosthetic infection. Agreement between pre-operative and intra-operative samples exceeds 75% in patients undergoing single-stage exchange of a hip or knee prosthesis to treat chronic peri-prosthetic infection. This single-centre retrospective study included 85 single-stage prosthesis exchange procedures in 82 patients with chronic peri-prosthetic infection at the hip or knee. Agreement between pre-operative and intra-operative sample results was evaluated. Changes to the initial antibiotic regimen made based on the intra-operative sample results were recorded. Of 149 pre-operative samples, 109 yielded positive cultures, in 75/85 cases. Of 452 intra-operative samples, 354 yielded positive cultures, in 85/85 cases. Agreement was complete in 54 (63%) cases and partial in 9 (11%) cases; there was no agreement in the remaining 22 (26%) cases. The complete agreement rate was significantly lower than 75% (P=0.01). The initial antibiotic regimen was inadequate in a single case. Pre-operative sampling may contribute to the diagnosis of peri-prosthetic infection but is neither necessary nor sufficient to confirm the diagnosis and identify the causative agent. The spectrum of the initial antibiotic regimen cannot be safely narrowed based on the pre-operative sample results. We suggest the routine prescription of a probabilistic broad-spectrum antibiotic regimen immediately after the prosthesis exchange, even when a pathogen was identified before surgery. IV, retrospective study. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  17. Factors Influencing Effective Writing.

    ERIC Educational Resources Information Center

    Muccino, Mary Ann; And Others

    Focusing on procedures and strategies suitable for teaching writing to students in grades 4, 6, and 8, this paper examines the factors that have been shown through research to influence effective writing. The paper divides the research examined into the categories of metacognition; socially-based writing strategies; theory-tested approaches to…

  18. Correctness of multi-detector-row computed tomography for diagnosing mechanical prosthetic heart valve disorders using operative findings as a gold standard.

    PubMed

    Tsai, I-Chen; Lin, Yung-Kai; Chang, Yen; Fu, Yun-Ching; Wang, Chung-Chi; Hsieh, Shih-Rong; Wei, Hao-Ji; Tsai, Hung-Wen; Jan, Sheng-Ling; Wang, Kuo-Yang; Chen, Min-Chi; Chen, Clayton Chi-Chang

    2009-04-01

    The purpose was to compare the findings of multi-detector computed tomography (MDCT) in prosthetic valve disorders using the operative findings as a gold standard. In a 3-year period, we prospectively enrolled 25 patients with 31 prosthetic heart valves. MDCT and transthoracic echocardiography (TTE) were done to evaluate pannus formation, prosthetic valve dysfunction, suture loosening (paravalvular leak) and pseudoaneurysm formation. Patients indicated for surgery received an operation within 1 week. The MDCT findings were compared with the operative findings. One patient with a Björk-Shiley valve could not be evaluated by MDCT due to a severe beam-hardening artifact; thus, the exclusion rate for MDCT was 3.2% (1/31). Prosthetic valve disorders were suspected in 12 patients by either MDCT or TTE. Six patients received an operation that included three redo aortic valve replacements, two redo mitral replacements and one Amplatzer ductal occluder occlusion of a mitral paravalvular leak. The concordance of MDCT for diagnosing and localizing prosthetic valve disorders and the surgical findings was 100%. Except for images impaired by severe beam-hardening artifacts, MDCT provides excellent delineation of prosthetic valve disorders.

  19. Recurrent pannus formation causing prosthetic aortic valve dysfunction: is excision without valve re-replacement applicable?

    PubMed

    Darwazah, Ahmad K

    2012-06-29

    Prosthetic valve dysfunction at aortic position is commonly caused by pannus formation. The exact etiology is not known. It arises from ventricular aspect of the prosthesis encroaching its leaflets causing stenosis or it may remain localized causing left ventricular outflow tract obstruction without affecting valve function.The difference in location entails different approaches in management. Such a pathology requires surgical excision of the pannus with or without valve re-replacement.A recurrent pannus was observed in a female patient who needed repeated surgical intervention to excise a localized pannus without re-replacement of a well functioning prosthetic valve.Management of our case presents several questions, whether recurrence of pannus is caused by sparing the prosthetic valve, is it simply an exaggeration of an inflammatory healing process in certain individuals or is it ideal to re-replace the valve despite a well preserved function.

  20. A new paradigm for obtaining marketing approval for pediatric-sized prosthetic heart valves.

    PubMed

    Yoganathan, Ajit P; Fogel, Mark; Gamble, Susan; Morton, Michael; Schmidt, Paul; Secunda, Jeff; Vidmar, Sara; Del Nido, Pedro

    2013-10-01

    Congenital heart valve disease is one of the most common abnormalities in children. There are limited technological solutions available for treating children with congenital heart valve diseases. The aim of this study is to provide the details of the consensus reached in terms of pediatric definitions, design approach, in vitro testing, and clinical trials, which may be used as guidance for developing prosthetic heart valves for the pediatric indication. In stark contrast to the various designs of adult-sized replacement valves available in the market, there are no Food and Drug Administration (FDA)-approved prosthetic heart valves available for use in the pediatric population. There is a pressing need for FDA-approved pediatric valve devices in the United States. The pediatric patient population has been typically excluded from replacement heart valve trials for several reasons. In January 2010, heart valve manufacturers and pediatric clinicians collaborated with academicians and FDA staff in a workshop to suggest ways to successfully evaluate pediatric prosthetic valves and conduct pediatric clinical trials to provide acceptable heart valve replacement options for this patient population. Recommendations, derived from ISO 5840:2005 and the 2010 FDA Draft Replacement Heart Valve Guidance, are provided for hydrodynamic, durability, and fatigue testing. The article specifically addresses in vitro and premarket and postmarket approval clinical studies that should be considered by a heart valve manufacturer for obtaining regulatory approval of pediatric sizes of prosthetic heart valve designs that are already approved for adult clinical use. Copyright © 2013 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  1. Factors influencing perceived angular velocity.

    PubMed

    Kaiser, M K; Calderone, J B

    1991-11-01

    The assumption that humans are able to perceive and process angular kinematics is critical to many structure-from-motion and optical flow models. The current studies investigate this sensitivity, and examine several factors likely to influence angular velocity perception. In particular, three factors are considered: (1) the extent to which perceived angular velocity is determined by edge transitions of surface elements, (2) the extent to which angular velocity estimates are influenced by instantaneous linear velocities of surface elements, and (3) whether element-velocity effects are related to three-dimensional (3-D) tangential velocities or to two-dimensional (2-D) image velocities. Edge-transition rate biased angular velocity estimates only when edges were highly salient. Element velocities influenced perceived angular velocity; this bias was related to 2-D image velocity rather than 3-D tangential velocity. Despite these biases, however, judgments were most strongly determined by the true angular velocity. Sensitivity to this higher order motion parameter was surprisingly good, for rotations both in depth (y-axis) and parallel to the line of sight (z-axis).

  2. Development and preliminary evaluation of a new anatomically based prosthetic alignment method for below-knee prosthesis.

    PubMed

    Tafti, Nahid; Karimlou, Masoud; Mardani, Mohammad Ali; Jafarpisheh, Amir Salar; Aminian, Gholam Reza; Safari, Reza

    2018-04-20

    The objectives of current study were to a) assess similarities and relationships between anatomical landmark-based angles and distances of lower limbs in unilateral transtibial amputees and b) develop and evaluate a new anatomically based static prosthetic alignment method. First sub-study assessed the anthropometrical differences and relationships between the lower limbs in the photographs taken from amputees. Data were analysed via paired t-test and regression analysis. Results show no significant differences in frontal and transverse planes. In the sagittal plane, the anthropometric parameters of the amputated limb were significantly correlated to the corresponding variables of the sound limb. The results served as bases for the development of a new prosthetic alignment method. The method was evaluated on a single subject study. Prosthetic alignment carried out by an experienced prosthetist was compared with such alignment adjusted by an inexperienced prosthetist but with the use of the developed method. In sagittal and frontal planes, the socket angle was tuned with respect to the shin angle, and the position of the prosthetic foot was tuned in relation to the pelvic landmarks. Further study is needed to assess the proposed method on a larger sample of amputees and prosthetists.

  3. Upper-limb prosthetic control using wearable multichannel mechanomyography.

    PubMed

    Wilson, Samuel; Vaidyanathan, Ravi

    2017-07-01

    In this paper we introduce a robust multi-channel wearable sensor system for capturing user intent to control robotic hands. The interface is based on a fusion of inertial measurement and mechanomyography (MMG), which measures the vibrations of muscle fibres during motion. MMG is immune to issues such as sweat, skin impedance, and the need for a reference signal that is common to electromyography (EMG). The main contributions of this work are: 1) the hardware design of a fused inertial and MMG measurement system that can be worn on the arm, 2) a unified algorithm for detection, segmentation, and classification of muscle movement corresponding to hand gestures, and 3) experiments demonstrating the real-time control of a commercial prosthetic hand (Bebionic Version 2). Results show recognition of seven gestures, achieving an offline classification accuracy of 83.5% performed on five healthy subjects and one transradial amputee. The gesture recognition was then tested in real time on subsets of two and five gestures, with an average accuracy of 93.3% and 62.2% respectively. To our knowledge this is the first applied MMG based control system for practical prosthetic control.

  4. Rapid Molecular Microbiologic Diagnosis of Prosthetic Joint Infection

    PubMed Central

    Cazanave, Charles; Greenwood-Quaintance, Kerryl E.; Hanssen, Arlen D.; Karau, Melissa J.; Schmidt, Suzannah M.; Gomez Urena, Eric O.; Mandrekar, Jayawant N.; Osmon, Douglas R.; Lough, Lindsay E.; Pritt, Bobbi S.; Steckelberg, James M.

    2013-01-01

    We previously showed that culture of samples obtained by prosthesis vortexing and sonication was more sensitive than tissue culture for prosthetic joint infection (PJI) diagnosis. Despite improved sensitivity, culture-negative cases remained; furthermore, culture has a long turnaround time. We designed a genus-/group-specific rapid PCR assay panel targeting PJI bacteria and applied it to samples obtained by vortexing and sonicating explanted hip and knee prostheses, and we compared the results to those with sonicate fluid and periprosthetic tissue culture obtained at revision or resection arthroplasty. We studied 434 subjects with knee (n = 272) or hip (n = 162) prostheses; using a standardized definition, 144 had PJI. Sensitivities of tissue culture, of sonicate fluid culture, and of PCR were 70.1, 72.9, and 77.1%, respectively. Specificities were 97.9, 98.3, and 97.9%, respectively. Sonicate fluid PCR was more sensitive than tissue culture (P = 0.04). PCR of prosthesis sonication samples is more sensitive than tissue culture for the microbiologic diagnosis of prosthetic hip and knee infection and provides same-day PJI diagnosis with definition of microbiology. The high assay specificity suggests that typical PJI bacteria may not cause aseptic implant failure. PMID:23658273

  5. Evaluation of p53 Polymorphism in Patients with Pannus-Derived Prosthetic Dysfunction.

    PubMed

    Gursoy, Mustafa Ozan; Karakoyun, Suleyman; Kalcik, Macit; Yesin, Mahmut; Gunduz, Sabahattin; Astarcioğlu, Mehmet Ali; Oğuz, Ali Emrah; Ozkan, Mehmet

    2015-09-01

    Prosthetic valve dysfunction (PVD) due to pannus formation is considered to occur due to a bioreaction to prosthetic material. The p53 gene plays a critical role in apoptosis and cell proliferation. p53 Arg72Pro polymorphism has been found to be associated with coronary stent restenosis, but has not yet been studied in prosthetic heart valve dysfunction. The study aim was to evaluate the association between pannus-derived PVD and p53 G72C(Arg72Pro) polymorphism. This single-center, prospective study included 25 patients (20 females, five males; mean age 45.6 +/- 12.5 years; group 1) who underwent redo valve surgery due to PVD, and 49 age- and gender-matched control patients (44 females, five males; mean age 47.3 +/- 12.2 years; group 2) with normofunctional prostheses. The prostheses were examined using transthoracic and transesophageal echocardiography. Analyses of p53 G72C(Arg72Pro) polymorphism were performed using Roche LightCyler 2.0 Real-time polymerase chain reaction. The most common location of replaced valves was the mitral position in both groups (88% and 89.8%, respectively). In group 1, normal alleles (GG) were observed in 12 patients (48%), while one patient (4%) showed a homozygous mutation (GC) and 12 patients (48%) showed a heterozygous mutation (CC). In group 2, 21 patients (42.9%) had normal alleles (GG), while four (8.2%) had a homozygous mutation (CC) and 24 (48.9%) had a heterozygous mutation (GC). No significant difference was observed between the groups with regards to p53 Arg72Pro polymorphism (p = 0.769). In patients with prosthetic valves, the underlying mechanism behind pannus formation is unrelated to p53 Arg72Pro polymorphism.

  6. Perceived self-efficacy and specific self-reported outcomes in persons with lower-limb amputation using a non-microprocessor-controlled versus a microprocessor-controlled prosthetic knee.

    PubMed

    Möller, Saffran; Hagberg, Kerstin; Samulesson, Kersti; Ramstrand, Nerrolyn

    2018-04-01

    To measure self-efficacy in a group of individuals who have undergone a lower-limb amputation and investigate the relationship between self-efficacy and prosthetic-specific outcomes including prosthetic use, mobility, amputation-related problems and global health. A second purpose was to examine if differences exist in outcomes based upon the type of prosthetic knee unit being used. Cross-sectional study using the General Self-Efficacy (GSE) Scale and the Questionnaire for Persons with a Transfemoral Amputation (Q-TFA). Forty-two individuals participated in the study. Twenty-three used a non-microprocessor-controlled prosthetic knee joint (non-MPK) and 19 used a microprocessor-controlled prosthetic knee joint (MPK). The study sample had quite high GSE scores (32/40). GSE scores were significantly correlated to the Q-TFA prosthetic use, mobility and problem scores. High GSE scores were related to higher levels of prosthetic use, mobility, global scores and negatively related to problem score. No significant difference was observed between individuals using a non-MPK versus MPK joints. Individuals with high self-efficacy used their prosthesis to a higher degree and high self-efficacy was related to higher level of mobility, global scores and fewer problems related to the amputation in individuals who have undergone a lower-limb amputation and were using a non-MPK or MPK knee. Implications for rehabilitation Perceived self-efficacy has has been shown to be related to quality of life, prosthetic mobility and capability as well as social activities in daily life. Prosthetic rehabilitation is primary focusing on physical improvement rather than psychological interventions. More attention should be directed towards the relationship between self-efficacy and prosthetic related outcomes during prosthetic rehabilitation after a lower-limb amputation.

  7. Optical 3D methods for measurement of prosthetic wear of total hip arthroplasty: principles, verification and results.

    PubMed

    Rossler, Tomas; Mandat, Dusan; Gallo, Jiri; Hrabovsky, Miroslav; Pochmon, Michal; Havranek, Vitezslav

    2009-07-20

    Total hip arthroplasty (THA) significantly improves the quality of life in majority of patients with severe osteoarthritis. However, long-term outcomes of THAs are compromised by aseptic loosening and periprosthetic osteolysis which needs revision surgery. Both of these are causally linked to a prosthetic wear deliberated from the prosthetic articulating surfaces. As a result, there is a need to measure the mode and magnitude of wear. The paper evaluates three optical methods proposed for construction of a device for the non-contact prosthetic wear measurement. Of them, the scanning profilometry achieved promising combination of accuracy and repeatability. Simultaneously, it is time efficient to enable the development of a sensor for wear measurement.

  8. A personalized 3D-printed prosthetic joint replacement for the human temporomandibular joint: From implant design to implantation.

    PubMed

    Ackland, David C; Robinson, Dale; Redhead, Michael; Lee, Peter Vee Sin; Moskaljuk, Adrian; Dimitroulis, George

    2017-05-01

    Personalized prosthetic joint replacements have important applications in cases of complex bone and joint conditions where the shape and size of off-the-shelf components may not be adequate. The objective of this study was to design, test and fabricate a personalized 3D-printed prosthesis for a patient requiring total joint replacement surgery of the temporomandibular joint (TMJ). The new 'Melbourne' prosthetic TMJ design featured a condylar component sized specifically to the patient and fixation screw positions that avoid potential intra-operative damage to the mandibular nerve. The Melbourne prosthetic TMJ was developed for a 58-year-old female recipient with end-stage osteoarthritis of the TMJ. The load response of the prosthesis during chewing and a maximum-force bite was quantified using a personalized musculoskeletal model of the patient's masticatory system developed using medical images. The simulations were then repeated after implantation of the Biomet Microfixation prosthetic TMJ, an established stock device. The maximum condylar stresses, screw stress and mandibular stress at the screw-bone interface were lower in the Melbourne prosthetic TMJ (259.6MPa, 312.9MPa and 198.4MPa, respectively) than those in the Biomet Microfixation device (284.0MPa, 416.0MPa and 262.2MPa, respectively) during the maximum-force bite, with similar trends also observed during the chewing bite. After trialing surgical placement and evaluating prosthetic TMJ stability using cadaveric specimens, the prosthesis was fabricated using 3D printing, sterilized, and implanted into the female recipient. Six months post-operatively, the prosthesis recipient had a normal jaw opening distance (40.0 mm), with no complications identified. The new design features and immediate load response of the Melbourne prosthetic TMJ suggests that it may provide improved clinical and biomechanical joint function compared to a commonly used stock device, and reduce risk of intra-operative nerve damage

  9. Social Factors Influencing Child Health in Ghana

    PubMed Central

    Quansah, Emmanuel; Ohene, Lilian Akorfa; Norman, Linda; Mireku, Michael Osei; Karikari, Thomas K.

    2016-01-01

    Objectives Social factors have profound effects on health. Children are especially vulnerable to social influences, particularly in their early years. Adverse social exposures in childhood can lead to chronic disorders later in life. Here, we sought to identify and evaluate the impact of social factors on child health in Ghana. As Ghana is unlikely to achieve the Millennium Development Goals’ target of reducing child mortality by two-thirds between 1990 and 2015, we deemed it necessary to identify social determinants that might have contributed to the non-realisation of this goal. Methods ScienceDirect, PubMed, MEDLINE via EBSCO and Google Scholar were searched for published articles reporting on the influence of social factors on child health in Ghana. After screening the 98 articles identified, 34 of them that met our inclusion criteria were selected for qualitative review. Results Major social factors influencing child health in the country include maternal education, rural-urban disparities (place of residence), family income (wealth/poverty) and high dependency (multiparousity). These factors are associated with child mortality, nutritional status of children, completion of immunisation programmes, health-seeking behaviour and hygiene practices. Conclusions Several social factors influence child health outcomes in Ghana. Developing more effective responses to these social determinants would require sustainable efforts from all stakeholders including the Government, healthcare providers and families. We recommend the development of interventions that would support families through direct social support initiatives aimed at alleviating poverty and inequality, and indirect approaches targeted at eliminating the dependence of poor health outcomes on social factors. Importantly, the expansion of quality free education interventions to improve would-be-mother’s health knowledge is emphasised. PMID:26745277

  10. Social Factors Influencing Child Health in Ghana.

    PubMed

    Quansah, Emmanuel; Ohene, Lilian Akorfa; Norman, Linda; Mireku, Michael Osei; Karikari, Thomas K

    2016-01-01

    Social factors have profound effects on health. Children are especially vulnerable to social influences, particularly in their early years. Adverse social exposures in childhood can lead to chronic disorders later in life. Here, we sought to identify and evaluate the impact of social factors on child health in Ghana. As Ghana is unlikely to achieve the Millennium Development Goals' target of reducing child mortality by two-thirds between 1990 and 2015, we deemed it necessary to identify social determinants that might have contributed to the non-realisation of this goal. ScienceDirect, PubMed, MEDLINE via EBSCO and Google Scholar were searched for published articles reporting on the influence of social factors on child health in Ghana. After screening the 98 articles identified, 34 of them that met our inclusion criteria were selected for qualitative review. Major social factors influencing child health in the country include maternal education, rural-urban disparities (place of residence), family income (wealth/poverty) and high dependency (multiparousity). These factors are associated with child mortality, nutritional status of children, completion of immunisation programmes, health-seeking behaviour and hygiene practices. Several social factors influence child health outcomes in Ghana. Developing more effective responses to these social determinants would require sustainable efforts from all stakeholders including the Government, healthcare providers and families. We recommend the development of interventions that would support families through direct social support initiatives aimed at alleviating poverty and inequality, and indirect approaches targeted at eliminating the dependence of poor health outcomes on social factors. Importantly, the expansion of quality free education interventions to improve would-be-mother's health knowledge is emphasised.

  11. Attenuation of centre-of-pressure trajectory fluctuations under the prosthetic foot when using an articulating hydraulic ankle attachment compared to fixed attachment.

    PubMed

    De Asha, Alan R; Johnson, Louise; Munjal, Ramesh; Kulkarni, Jai; Buckley, John G

    2013-02-01

    Disruptions to the progress of the centre-of-pressure trajectory beneath prosthetic feet have been reported previously. These disruptions reflect how body weight is transferred over the prosthetic limb and are governed by the compliance of the prosthetic foot device and its ability to simulate ankle function. This study investigated whether using an articulating hydraulic ankle attachment attenuates centre-of-pressure trajectory fluctuations under the prosthetic foot compared to a fixed attachment. Twenty active unilateral trans-tibial amputees completed walking trials at their freely-selected, comfortable walking speed using both their habitual foot with either a rigid or elastic articulating attachment and a foot with a hydraulic ankle attachment. Centre-of-pressure displacement and velocity fluctuations beneath the prosthetic foot, prosthetic shank angular velocity during stance, and walking speed were compared between foot conditions. Use of the hydraulic device eliminated or reduced the magnitude of posteriorly directed centre-of-pressure displacements, reduced centre-of-pressure velocity variability across single-support, increased mean forward angular velocity of the shank during early stance, and increased freely chosen comfortable walking speed (P ≤ 0.002). The attenuation of centre-of-pressure trajectory fluctuations when using the hydraulic device indicated bodyweight was transferred onto the prosthetic limb in a smoother, less faltering manner which allowed the centre of mass to translate more quickly over the foot. Copyright © 2012 Elsevier Ltd. All rights reserved.

  12. Factors potentially influencing aminoglycoside use and expenditure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DiPiro, J.T.; Kilsdonk, G.F.; Amerson, A.B.

    1982-07-01

    Factors that may have influenced aminoglycoside use and expenditure in one hospital were examined. Factors that were evaluated as to their influence on aminoglycoside-use patterns were: (1) formulary status; (2) bacterial susceptibility patterns; (3) identified or perceived differences in toxicity; (4) changes in patient population; (5) price paid by the hospital for aminoglycosides; (6) distribution of newsletters or memoranda; (7) advertising and detailing; and (8) pharmacy policies. For FY 1976-77 to 1979-80, the largest proportion of aminoglycoside expense was for gentamicin. During FY 1980-81, the expenditure for gentamicin decreased and tobramycin accounted for the largest proportion of total expenditure. Monthlymore » gentamicin use decreased 20% during FY 1980-81 from the previous year. Tobramycin use increased from January 1979 to November 1980 and decreased from December 1980 to June 1981. Kanamycin use and amikacin use were fairly constant during the study period. Based on temporal relationships, the following factors appeared to influence aminoglycoside use and expenditure: (1) a study conducted at the institution from June 1977 to June 1979 comparing gentamicin and tobramycin nephrotoxicity; (2) a comparative nephrotoxicity study published in a widely circulated medical journal in May 1980; and (3) an intramural newsletter and memorandum distributed in March 1981 encouraging selective aminoglycoside use. The identification of factors that potentially influenced aminoglycoside use can be used to anticipate the future impact of similar events and to devise strategies to influence antimicrobial use.« less

  13. Cryopreserved Cadaveric Arterial Allograft for Arterial Reconstruction in Patients with Prosthetic Infection.

    PubMed

    Lejay, Anne; Delay, Charline; Girsowicz, Elie; Chenesseau, Bettina; Bonnin, Emilie; Ghariani, Mohamed-Zied; Thaveau, Fabien; Georg, Yannick; Geny, Bernard; Chakfe, Nabil

    2017-11-01

    The aim of this study was to report outcomes of cryopreserved arterial allografts used as a vascular substitute in the setting of prosthetic material infection. A retrospective analysis of prospectively collected data was conducted including all consecutive interventions performed with cryopreserved arterial allografts used for vascular reconstruction in the setting of prosthetic material infection between January 2005 and December 2014. Five year outcomes included allograft related re-interventions, survival, primary patency, and limb salvage rates. Fifty-three procedures were performed using cryopreserved allografts for vascular prosthetic infection: 25 procedures (47%) were performed at aorto-iliac level (Group 1) and 28 procedures (53%) at peripheral level (Group 2). The mean follow-up was 52 months. Five year allograft related re-intervention was 55% in Group 1 (6 allograft ruptures and 5 allograft aneurysm degenerations) and 33% in Group 2 (2 allograft ruptures and 7 allograft aneurysm degenerations). Five year survival was 40% and 68%, primary patency was 89% and 59% and limb salvage was 100% and 89% for Group 1 and 2 respectively. Use of cryopreserved arterial allografts provides acceptable results but is tempered by suboptimal 5 year outcomes with high re-intervention rates. Copyright © 2017 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  14. Recurrent pannus formation causing prosthetic aortic valve dysfunction: Is excision without valve re-replacement applicable?

    PubMed Central

    2012-01-01

    Prosthetic valve dysfunction at aortic position is commonly caused by pannus formation. The exact etiology is not known. It arises from ventricular aspect of the prosthesis encroaching its leaflets causing stenosis or it may remain localized causing left ventricular outflow tract obstruction without affecting valve function. The difference in location entails different approaches in management. Such a pathology requires surgical excision of the pannus with or without valve re-replacement. A recurrent pannus was observed in a female patient who needed repeated surgical intervention to excise a localized pannus without re-replacement of a well functioning prosthetic valve. Management of our case presents several questions, whether recurrence of pannus is caused by sparing the prosthetic valve, is it simply an exaggeration of an inflammatory healing process in certain individuals or is it ideal to re-replace the valve despite a well preserved function. PMID:22747790

  15. [Ectodermal Capdepont syndrome and oral prosthetic rehabilitation. About a clinical case].

    PubMed

    Kumpanya, P; Matshumba, M; Sekele, I B; Mayunga, M; Lutula, P S; Ntumba, M K

    2015-03-01

    The authors describe the ectodermal Capdepont syndrome as an anomaly characterized by anhidrosis, hypotrichosis and anodontia diagnosed in a 22 year-old adult. In front of this anodontia, oral prosthetic rehabilitation remains the only solution.

  16. Prosthetic metal implants and airport metal detectors

    PubMed Central

    Dancey, A; Titley, OG

    2013-01-01

    Introduction Metal detectors have been present in airports and points of departure for some time. With the introduction of heightened security measures in response to fears of an increased threat of terrorism, they may become more prevalent in other public locations. The aim of this study was to ascertain which prosthetic devices activated metal detector devices used for security purposes. Methods A range of prosthetic devices used commonly in orthopaedic and plastic surgery procedures were passed through an arch metal detector at Birmingham Airport in the UK. Additionally, each item was passed under a wand detector. Items tested included expandable breast prostheses, plates used in wrist and hand surgery, screws, K-wires, Autosuture™ ligation clips and staples. Results No prostheses were detected by the arch detector. The expandable implants and wrist plates were the only devices detected by passing the wand directly over them. No device was detected by the wand when it was under cover of the axillary soft tissue. Screws, K-wires, Autosuture™ clips and staples were not detected under any of the study conditions. Conclusions Although unlikely to trigger a detector, it is possible that an expandable breast prosthesis or larger plate may do so. It is therefore best to warn patients of this so they can anticipate detection and further examination. PMID:23827294

  17. A review of functional outcomes related to prosthetic treatment after maxillary and mandibular reconstruction in patients with head and neck cancer.

    PubMed

    Tang, Judith A Lam; Rieger, Jana M; Wolfaardt, Johan F

    2008-01-01

    This review examined literature that reported functional outcomes across 3 categories of prosthetic treatment after microvascular reconstruction of the maxilla and mandible: (1) conventional dental/tissue-supported prosthesis, (2) implant-retained prosthesis, and (3) no prosthesis. Library databases were searched for articles related to reconstruction of the maxilla and mandible, and references of selected articles were hand searched. Relevant literature was identified and reviewed with criteria specified a priori. Forty-nine articles met the inclusion criteria. Twelve articles reported on function after maxillary reconstruction, with the majority of articles reporting on outcomes for 1 to 6 subjects. Thirty-nine articles reported on function after mandibular reconstruction. Speech outcomes were satisfactory across all groups. Swallowing reports indicated that many patients who received either type of prosthetic rehabilitation resumed a normal diet, whereas those without prosthetic rehabilitation were often restricted to liquid diets or feeding tubes. Patients without prosthetic rehabilitation reportedly had poor masticatory ability, whereas conventional prosthetic treatment allowed some recovery of mastication and implant-retained prosthetic treatment resulted in the most favorable masticatory outcomes. Quality-of-life outcomes were similar across all patients. Several limitations of the current literature prevented definitive conclusions from being reached within this review, especially regarding maxillary reconstruction. However, recognition of these limitations can direct functional assessment for the future.

  18. Influence of organizational factors on safety

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Haber, S.B.; Metlay, D.S.; Crouch, D.A.

    There is a need for a better understanding of exactly how organizational management factors at a nuclear power plant (NPP) affect plant safety performance, either directly or indirectly, and how these factors might be observed, measured, and evaluated. The purpose of this research project is to respond to that need by developing a general methodology for characterizing these organizational and management factors, systematically collecting information on their status and integrating that information into various types of evaluative activities. Research to date has included the development of the Nuclear Organization and Management Analysis Concept (NOMAC) of a NPP, the identification ofmore » key organizational and management factors, and the identification of the methods for systematically measuring and analyzing the influence of these factors on performance. Most recently, two field studies, one at a fossil fuel plant and the other at a NPP, were conducted using the developed methodology. Results are presented from both studies highlighting the acceptability, practicality, and usefulness of the methods used to assess the influence of various organizational and management factors including culture, communication, decision-making, standardization, and oversight. 6 refs., 3 figs., 1 tab.« less

  19. Factors Influencing Resident Choice of Prosthodontic Residency Program.

    PubMed

    Wojnarwsky, Pandora Keala Lee; Wang, Yan; Shah, Kumar; Koka, Sreenivas

    2017-06-01

    The decision by prosthodontic residency program directors to employ the Match process highlights the need to understand applicant priorities that influence their choice of which programs to rank highly. The purpose of this study is to determine the factors that were most important to residents when choosing from among nonmilitary based prosthodontics dental residency programs in the United States. Following completion of a pilot study, all currently enrolled prosthodontic residents at nonmilitary residency programs were invited to participate via the internet. The study consisted of a survey instrument asking residents to rank 26 possible factors that might impact an applicant's choice of residency program. In addition, the instrument collected other possible influencing variables including gender and debt load. Mean rank scores were compared to determine the most and least important factors. Kruskal-Wallis test was used to compare specific factors between the possible influencing variables. Two hundred and thirty residents completed the survey instrument, representing a 54.1% response rate of possible participants. With regard to factors influencing program choice, reputation of the residency program was the factor ranked the highest by participants, followed in descending order by the program director's personality, curriculum content, access to use of the latest digital technology, and opportunities for dental implant placement. Quality of schools for children, community outreach opportunities, and the ability to moonlight were ranked as the least important factors. Male and female residents ranked factors such as tuition/stipend, curriculum content, and community outreach opportunities significantly differently. Depending on debt load, residents ranked the factors tuition/stipend, ability to moonlight, curriculum content, and safety of the area where the program is differently. Current prosthodontic residents valued the reputation of the program as the most

  20. Illusory movement perception improves motor control for prosthetic hands.

    PubMed

    Marasco, Paul D; Hebert, Jacqueline S; Sensinger, Jon W; Shell, Courtney E; Schofield, Jonathon S; Thumser, Zachary C; Nataraj, Raviraj; Beckler, Dylan T; Dawson, Michael R; Blustein, Dan H; Gill, Satinder; Mensh, Brett D; Granja-Vazquez, Rafael; Newcomb, Madeline D; Carey, Jason P; Orzell, Beth M

    2018-03-14

    To effortlessly complete an intentional movement, the brain needs feedback from the body regarding the movement's progress. This largely nonconscious kinesthetic sense helps the brain to learn relationships between motor commands and outcomes to correct movement errors. Prosthetic systems for restoring function have predominantly focused on controlling motorized joint movement. Without the kinesthetic sense, however, these devices do not become intuitively controllable. We report a method for endowing human amputees with a kinesthetic perception of dexterous robotic hands. Vibrating the muscles used for prosthetic control via a neural-machine interface produced the illusory perception of complex grip movements. Within minutes, three amputees integrated this kinesthetic feedback and improved movement control. Combining intent, kinesthesia, and vision instilled participants with a sense of agency over the robotic movements. This feedback approach for closed-loop control opens a pathway to seamless integration of minds and machines. Copyright © 2018 The Authors, some rights reserved; exclusive licensee American Association for the Advancement of Science. No claim to original U.S. Government Works.

  1. A powered prosthetic ankle joint for walking and running.

    PubMed

    Grimmer, Martin; Holgate, Matthew; Holgate, Robert; Boehler, Alexander; Ward, Jeffrey; Hollander, Kevin; Sugar, Thomas; Seyfarth, André

    2016-12-19

    Current prosthetic ankle joints are designed either for walking or for running. In order to mimic the capabilities of an able-bodied, a powered prosthetic ankle for walking and running was designed. A powered system has the potential to reduce the limitations in range of motion and positive work output of passive walking and running feet. To perform the experiments a controller capable of transitions between standing, walking, and running with speed adaptations was developed. In the first case study the system was mounted on an ankle bypass in parallel with the foot of a non-amputee subject. By this method the functionality of hardware and controller was proven. The Walk-Run ankle was capable of mimicking desired torque and angle trajectories in walking and running up to 2.6 m/s. At 4 m/s running, ankle angle could be matched while ankle torque could not. Limited ankle output power resulting from a suboptimal spring stiffness value was identified as a main reason. Further studies have to show to what extent the findings can be transferred to amputees.

  2. Identification of dynamic load for prosthetic structures.

    PubMed

    Zhang, Dequan; Han, Xu; Zhang, Zhongpu; Liu, Jie; Jiang, Chao; Yoda, Nobuhiro; Meng, Xianghua; Li, Qing

    2017-12-01

    Dynamic load exists in numerous biomechanical systems, and its identification signifies a critical issue for characterizing dynamic behaviors and studying biomechanical consequence of the systems. This study aims to identify dynamic load in the dental prosthetic structures, namely, 3-unit implant-supported fixed partial denture (I-FPD) and teeth-supported fixed partial denture. The 3-dimensional finite element models were constructed through specific patient's computerized tomography images. A forward algorithm and regularization technique were developed for identifying dynamic load. To verify the effectiveness of the identification method proposed, the I-FPD and teeth-supported fixed partial denture structures were investigated to determine the dynamic loads. For validating the results of inverse identification, an experimental force-measuring system was developed by using a 3-dimensional piezoelectric transducer to measure the dynamic load in the I-FPD structure in vivo. The computationally identified loads were presented with different noise levels to determine their influence on the identification accuracy. The errors between the measured load and identified counterpart were calculated for evaluating the practical applicability of the proposed procedure in biomechanical engineering. This study is expected to serve as a demonstrative role in identifying dynamic loading in biomedical systems, where a direct in vivo measurement may be rather demanding in some areas of interest clinically. Copyright © 2017 John Wiley & Sons, Ltd.

  3. Transposed brachial-basilic arteriovenous fistulas versus prosthetic upper limb grafts: a meta-analysis.

    PubMed

    Lazarides, M K; Georgiadis, G S; Papasideris, C P; Trellopoulos, G; Tzilalis, V D

    2008-11-01

    Controversy exists regarding the best type of arteriovenous (AV) fistula to be formed in secondary and tertiary access procedures when primary fistulas have failed. This meta-analysis aimed to compare transposed brachial-basilic AV fistulas (BBAVFs) with upper limb AV prosthetic grafts. A literature search of the MEDLINE and SCOPUS databases was performed to identify comparative studies reporting outcomes for both BBAVFs with upper limb AV prosthetic grafts. Meta-analysis techniques were applied to identify differences in outcomes between the two groups regarding primary and secondary 1-year failure rates. Eleven relevant studies, involving 1509 patients, met the inclusion criteria and were incorporated in the final analysis; however, only one was randomised controlled trial. The pooled odds' ratio (OR) estimate for the primary and secondary failure rates at 1 year was 0.67 (CI 0.41-1.09) and 0.88 (CI 0.69-1.12), respectively, showing no difference in the outcome between the two groups. The re-intervention rate was higher for prosthetic grafts (0.54 per BBAVF versus 1.32 per graft). In a small subgroup of two studies comparing BBAVFs with forearm grafts the pooled estimate for 1-year primary failure rate was in favour of the BBAVF group (OR 0.3, CI 0.15-0.58, p=0.0004) suggesting that forearm grafts were inferior having a 3-fold risk of failure at 1 year. This analysis supports the use of BBAVF early in difficult access cases prior to the use of prosthetic grafts. However, the latter conclusion is debatable due to heterogeneity, small size and non-randomised design of the included studies.

  4. Silver Nanocoating Technology in the Prevention of Prosthetic Joint Infection

    PubMed Central

    Gallo, Jiri; Panacek, Ales; Prucek, Robert; Kriegova, Eva; Hradilova, Sarka; Hobza, Martin; Holinka, Martin

    2016-01-01

    Prosthetic joint infection (PJI) is a feared complication of total joint arthroplasty associated with increased morbidity and mortality. There is a growing body of evidence that bacterial colonization and biofilm formation are critical pathogenic events in PJI. Thus, the choice of biomaterials for implanted prostheses and their surface modifications may significantly influence the development of PJI. Currently, silver nanoparticle (AgNP) technology is receiving much interest in the field of orthopaedics for its antimicrobial properties and a strong anti-biofilm potential. The great advantage of AgNP surface modification is a minimal release of active substances into the surrounding tissue and a long period of effectiveness. As a result, a controlled release of AgNPs could ensure antibacterial protection throughout the life of the implant. Moreover, the antibacterial effect of AgNPs may be strengthened in combination with conventional antibiotics and other antimicrobial agents. Here, our main attention is devoted to general guidelines for the design of antibacterial biomaterials protected by AgNPs, its benefits, side effects and future perspectives in PJI prevention. PMID:28773461

  5. Multidisciplinary Treatment Approach for Prosthetic Vascular Graft Infection in the Thoracic Aortic Area

    PubMed Central

    Watanabe, Yoshinori

    2015-01-01

    Prosthetic vascular graft infection in the thoracic aortic area is a rare but serious complication. Adequate management of the complication is essential to increase the chance of success of open surgery. While surgical site infection is suggested as the root cause of the complication, it is also related to decreased host tolerance, especially as found in elderly patients. The handling of prosthetic vascular graft infection has been widely discussed to date. This paper mainly provides a summary of literature reports published within the past 5 years to discuss issues related to multidisciplinary treatment approaches, including surgical site infection, timing of onset, diagnostic methods, causative pathogens, auxiliary diagnostic methods, antibiotic treatment, anti-infective structures of vascular prostheses, surgical treatment, treatment strategy against infectious aortic aneurysms, future surgical treatment, postoperative systemic therapy, and antimicrobial stewardship. A thorough understanding of these issues will enable us to prevent prosthetic vascular graft infection in the thoracic aortic area as far as possible. In the event of its occurrence, the early introduction of appropriate treatment is expected to cure the disease without worsening of the underlying pathological condition. PMID:26356686

  6. Treatment Challenges of Prosthetic Hip Infection with Associated Iliacus Muscle Abscess: Report of 5 Cases and Literature Review.

    PubMed

    Lawrenz, Joshua M; Mesko, Nathan W; Higuera, Carlos A; Molloy, Robert M; Simpfendorfer, Claus; Babic, Maja

    2017-01-01

    Prosthetic joint infection is an unfortunate though well-recognized complication of total joint arthroplasty. An iliacus and/or iliopsoas muscle abscess is a rarely documented presentation of hip prosthetic joint infection. It is thought an unrecognized retroperitoneal nidus of infection can be a source of continual seeding of the prosthetic hip joint, prolonging attempts to eradicate infection despite aggressive debridement and explant attempts. The current study presents five cases demonstrating this clinical scenario, and discusses various treatment challenges. In each case we report the patient's clinical history, pertinent imaging, management and outcome. Diagnosis of the iliacus muscle abscess was made using computed tomography imaging. In brief, the mean number of total drainage procedures (open and percutaneous) per patient was 4.2, and outcomes consisted of one patient with a hip girdlestone, two patients with delayed revisions, and two patients with retained prosthesis. All patients ended with functional pain and on oral antibiotic suppression with an average follow up of 18 months. This article highlights an iliacus muscle abscess as an unrecognized source of infection to a prosthetic hip. It demonstrates resilience to standard treatment protocols for prosthetic hip infection, and is associated with poor patient outcomes. Aggressive surgical debridement appears to remain critical to treatment success, and early retroperitoneal debridement of the abscess should be considered.

  7. A three-dimensional finite element study on the stress distribution pattern of two prosthetic abutments for external hexagon implants.

    PubMed

    Moreira, Wagner; Hermann, Caio; Pereira, Jucélio Tomás; Balbinoti, Jean Anacleto; Tiossi, Rodrigo

    2013-10-01

    The purpose of this study was to evaluate the mechanical behavior of two different straight prosthetic abutments (one- and two-piece) for external hex butt-joint connection implants using three-dimensional finite element analysis (3D-FEA). Two 3D-FEA models were designed, one for the two-piece prosthetic abutment (2 mm in height, two-piece mini-conical abutment, Neodent) and another one for the one-piece abutment (2 mm in height, Slim Fit one-piece mini-conical abutment, Neodent), with their corresponding screws and implants (Titamax Ti, 3.75 diameter by 13 mm in length, Neodent). The model simulated the single restoration of a lower premolar using data from a computerized tomography of a mandible. The preload (20 N) after torque application for installation of the abutment and an occlusal loading were simulated. The occlusal load was simulated using average physiological bite force and direction (114.6 N in the axial direction, 17.1 N in the lingual direction and 23.4 N toward the mesial at an angle of 75° to the occlusal plan). The regions with the highest von Mises stress results were at the bottom of the initial two threads of both prosthetic abutments that were tested. The one-piece prosthetic abutment presented a more homogeneous behavior of stress distribution when compared with the two-piece abutment. Under the simulated chewing loads, the von Mises stresses for both tested prosthetic-abutments were within the tensile strength values of the materials analyzed which thus supports the clinical use of both prosthetic abutments.

  8. Factors influencing pacing in triathlon

    PubMed Central

    Wu, Sam SX; Peiffer, Jeremiah J; Brisswalter, Jeanick; Nosaka, Kazunori; Abbiss, Chris R

    2014-01-01

    Triathlon is a multisport event consisting of sequential swim, cycle, and run disciplines performed over a variety of distances. This complex and unique sport requires athletes to appropriately distribute their speed or energy expenditure (ie, pacing) within each discipline as well as over the entire event. As with most physical activity, the regulation of pacing in triathlon may be influenced by a multitude of intrinsic and extrinsic factors. The majority of current research focuses mainly on the Olympic distance, whilst much less literature is available on other triathlon distances such as the sprint, half-Ironman, and Ironman distances. Furthermore, little is understood regarding the specific physiological, environmental, and interdisciplinary effects on pacing. Therefore, this article discusses the pacing strategies observed in triathlon across different distances, and elucidates the possible factors influencing pacing within the three specific disciplines of a triathlon. PMID:25258562

  9. Incremental benefit of 3D transesophageal echocardiography: a case of a mass overlying a prosthetic mitral valve.

    PubMed

    Tauras, James M; Zhang, Zhihang; Taub, Cynthia C

    2011-05-01

    A young woman with a mechanical mitral valve and prosthetic mitral stenosis underwent multiple imaging modalities (including transthoracic ECHO, fluoroscopy, and two-dimensional transesophageal ECHO) to determine the cause of her stenosis. Only three-dimensional transesophageal echocardiography demonstrated the full size and extent of an obstructing mass on the strut and sewing ring of the prosthetic mitral valve. © 2011, Wiley Periodicals, Inc.

  10. Replicating Physiological Patterns of Activity with Prosthetic Stimulation

    DTIC Science & Technology

    2008-07-01

    from retinitis pigmentosa : Arch Ophthalmol, v. 122, p. 460-9. 8 Dacey, D. M., B. B. Peterson, F. R. Robinson, and P. D. Gamlin, 2003, Fireworks in...with DTL electrodes: a study in patients with retinitis pigmentosa , glaucoma, and homonymous visual field loss and normal subjects: Invest Ophthalmol...outcomes associated with retinal prosthetics. To accomplish this, we are investigating the mechanism(s) by which different types of retinal neurons

  11. Method of making self-cleaning skin-like prosthetic polymer surfaces

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Simpson, John T.; Ivanov, Ilia N.; Shibata, Jason

    An external covering and method of making an external covering for hiding the internal endoskeleton of a mechanical (e.g., prosthetic) device that exhibits skin-like qualities is provided. The external covering generally comprises an internal bulk layer in contact with the endoskeleton of the prosthetic device and an external skin layer disposed about the internal bulk layer. The external skin layer is comprised of a polymer composite with carbon nanotubes embedded therein. The outer surface of the skin layer has multiple cone-shaped projections that provide the external skin layer with superhydrophobicity. The carbon nanotubes are preferably vertically aligned between the innermore » surface and outer surface of the external skin layer in order to provide the skin layer with the ability to transmit heat. Superhydrophobic powders may optionally be used as part of the polymer composite or applied as a coating to the surface of the skin layer to enhance superhydrophobicity.« less

  12. Microbiological Aetiology, Epidemiology, and Clinical Profile of Prosthetic Joint Infections: Are Current Antibiotic Prophylaxis Guidelines Effective?

    PubMed Central

    Cheng, Allen C.; Buising, Kirsty L.; Choong, Peter F. M.

    2012-01-01

    Prosthetic joint infections remain a major complication of arthroplasty. At present, local and international guidelines recommend cefazolin as a surgical antibiotic prophylaxis at the time of arthroplasty. This retrospective cohort study conducted across 10 hospitals over a 3-year period (January 2006 to December 2008) investigated the epidemiology and microbiological etiology of prosthetic joint infections. There were 163 cases of prosthetic joint infection identified. From a review of the microbiological culture results, methicillin-resistant Staphylococcus aureus (MRSA) and coagulase-negative staphylococci were isolated in 45% of infections. In addition, polymicrobial infections, particularly those involving Gram-negative bacilli and enterococcal species, were common (36%). The majority (88%) of patients received cefazolin as an antibiotic prophylaxis at the time of arthroplasty. In 63% of patients in this cohort, the microorganisms subsequently obtained were not susceptible to the antibiotic prophylaxis administered. The results of this study highlight the importance of ongoing reviews of the local ecology of prosthetic joint infection, demonstrating that the spectrum of pathogens involved is broad. The results should inform empirical antibiotic therapy. This report also provokes discussion about infection control strategies, including changing surgical antibiotic prophylaxis to a combination of glycopeptide and cefazolin, to reduce the incidence of infections due to methicillin-resistant staphylococci. PMID:22314530

  13. Effects of alignment on the roll-over shapes of prosthetic feet.

    PubMed

    Hansen, Andrew

    2008-12-01

    Recent work suggests that a prosthetic ankle-foot component's roll-over shape - the effective rocker it conforms to between initial contact and opposite initial contact (the 'roll-over' interval of walking) - is closely linked to its final alignment in the prosthesis (as determined by a skilled prosthetist using heuristic techniques). If true, this information may help to determine the appropriate alignment for a lower limb prosthesis before it is built, or a priori. Knowledge is needed for future models that will incorporate the roll-over shape including the relative effect of alignment on the roll-over shape's radius of curvature and arc length. The purpose of this study was to evaluate the hypotheses that: (i) Changes in prosthesis alignment alter the position and orientation of a foot's roll-over shape in prosthesis-based coordinates, and (ii) these changes occur without changing the radius of curvature or arc length of the roll-over shape. To examine the hypotheses, this study examined the effects of nine alignment settings on the roll-over shapes of two prosthetic feet. The idea that alignment changes move and rotate roll-over shapes of prosthetic feet in prosthesis coordinates is supported by this work, but the hypothesis that the radius of curvature and arc length do not change for different alignments is not strongly supported by the data. A revised approach is presented that explains some of the changes to the roll-over shape parameters due to changes in rotational alignment.

  14. Analysis of clinically important factors on the performance of advanced hydraulic, microprocessor-controlled exo-prosthetic knee joints based on 899 trial fittings.

    PubMed

    Hahn, Andreas; Lang, Michael; Stuckart, Claudia

    2016-11-01

    The objective of this work is to evaluate whether clinically important factors may predict an individual's capability to utilize the functional benefits provided by an advanced hydraulic, microprocessor-controlled exo-prosthetic knee component.This retrospective cross-sectional cohort analysis investigated the data of above knee amputees captured during routine trial fittings. Prosthetists rated the performance indicators showing the functional benefits of the advanced maneuvering capabilities of the device. Subjects were asked to rate their perception. Simple and multiple linear and logistic regression was applied.Data from 899 subjects with demographics typical for the population were evaluated. Ability to vary gait speed, perform toileting, and ascend stairs were identified as the most sensitive performance predictors. Prior C-Leg users showed benefits during advanced maneuvering. Variables showed plausible and meaningful effects, however, could not claim predictive power. Mobility grade showed the largest effect but also failed to be predictive.Clinical parameters such as etiology, age, mobility grade, and others analyzed here do not suffice to predict individual potential. Daily walking distance may pose a threshold value and be part of a predictive instrument. Decisions based solely on single parameters such as mobility grade rating or walking distance seem to be questionable.

  15. In vitro activity of ceftaroline against staphylococci from prosthetic joint infection.

    PubMed

    Park, Kyung-Hwa; Greenwood-Quaintance, Kerryl E; Patel, Robin

    2016-02-01

    We tested the in vitro activity of ceftaroline by Etest against staphylococci recovered from patients with prosthetic joint infection, including 97 Staphylococcus aureus isolates (36%, oxacillin resistant) and 74 Staphylococcus epidermidis isolates (74%, oxacillin resistant). Ceftaroline inhibited all staphylococci at ≤0.5 μg/mL. The ceftaroline MIC(90/50) values for methicillin-susceptible S. aureus, methicillin-susceptible S. epidermidis, methicillin-resistant S. aureus, and methicillin-resistant S. epidermidis were 0.19/0.125, 0.094/0.047, 0.5/0.38, and 0.38/0.19 μg/mL, respectively. Based on these in vitro findings, ceftaroline should be further evaluated as a potential therapeutic option for the treatment of prosthetic joint infection caused by methicillin-susceptible and methicillin-resistant S. aureus and S. epidermidis. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Prosthetic helping hand

    NASA Technical Reports Server (NTRS)

    Vest, Thomas W. (Inventor); Carden, James R. (Inventor); Norton, William E. (Inventor); Belcher, Jewell G. (Inventor)

    1992-01-01

    A prosthetic device for below-the-elbow amputees, having a C-shaped clamping mechanism for grasping cylindrical objects, is described. The clamping mechanism is pivotally mounted to a cuff that fits on the amputee's lower arm. The present invention is utilized by placing an arm that has been amputated below the elbow into the cuff. The clamping mechanism then serves as a hand whenever it becomes necessary for the amputee to grasp a cylindrical object such as a handle, a bar, a rod, etc. To grasp the cylindrical object, the object is jammed against the opening in the C-shaped spring, causing the spring to open, the object to pass to the center of the spring, and the spring to snap shut behind the object. Various sizes of clamping mechanisms can be provided and easily interchanged to accommodate a variety of diameters. With the extension that pivots and rotates, the clamping mechanism can be used in a variety of orientations. Thus, this invention provides the amputee with a clamping mechanism that can be used to perform a number of tasks.

  17. Enhanced ultrasound for advanced diagnostics, ultrasound tomography for volume limb imaging and prosthetic fitting

    NASA Astrophysics Data System (ADS)

    Anthony, Brian W.

    2016-04-01

    Ultrasound imaging methods hold the potential to deliver low-cost, high-resolution, operator-independent and nonionizing imaging systems - such systems couple appropriate algorithms with imaging devices and techniques. The increasing demands on general practitioners motivate us to develop more usable and productive diagnostic imaging equipment. Ultrasound, specifically freehand ultrasound, is a low cost and safe medical imaging technique. It doesn't expose a patient to ionizing radiation. Its safety and versatility make it very well suited for the increasing demands on general practitioners, or for providing improved medical care in rural regions or the developing world. However it typically suffers from sonographer variability; we will discuss techniques to address user variability. We also discuss our work to combine cylindrical scanning systems with state of the art inversion algorithms to deliver ultrasound systems for imaging and quantifying limbs in 3-D in vivo. Such systems have the potential to track the progression of limb health at a low cost and without radiation exposure, as well as, improve prosthetic socket fitting. Current methods of prosthetic socket fabrication remain subjective and ineffective at creating an interface to the human body that is both comfortable and functional. Though there has been recent success using methods like magnetic resonance imaging and biomechanical modeling, a low-cost, streamlined, and quantitative process for prosthetic cup design and fabrication has not been fully demonstrated. Medical ultrasonography may inform the design process of prosthetic sockets in a more objective manner. This keynote talk presents the results of progress in this area.

  18. A Mobile Motion Analysis System Using Intertial Sensors for Analysis of Lower Limb Prosthetics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mueller, John Kyle P; Ericson, Milton Nance; Farquhar, Ethan

    Soldiers returning from the global war on terror requiring lower leg prosthetics generally have different concerns and requirements than the typical lower leg amputee. These subjects are usually young, wish to remain active and often desire to return to active military duty. As such, they demand higher performance from their prosthetics, but are at risk for chronic injury and joint conditions in their unaffected limb. Motion analysis is a valuable tool in assessing the performance of new and existing prosthetic technologies as well as the methods in fitting these devices to both maximize performance and minimize risk of injury formore » the individual soldier. We are developing a mobile, low-cost motion analysis system using inertial measurement units (IMUs) and two custom force sensors that detect ground reaction forces and moments on both the unaffected limb and prosthesis. IMUs were tested on a robot programmed to simulate human gait motion. An algorithm which uses a kinematic model of the robot and an extended Kalman filter (EKF) was used to convert the rates and accelerations from the gyro and accelerometer into joint angles. Compared to encoder data from the robot, which was considered the ground truth in this experiment, the inertial measurement system had a RMSE of <1.0 degree. Collecting kinematic and kinetic data without the restrictions and expense of a motion analysis lab could help researchers, designers and prosthetists advance prosthesis technology and customize devices for individuals. Ultimately, these improvements will result in better prosthetic performance for the military population.« less

  19. "Look and feel your best": representations of artificial limb users in prosthetic company advertisements.

    PubMed

    Murray, Craig D; Forshaw, Mark J

    2014-01-01

    Artificial limbs (prosthetics) are considered important for keeping the person physically active and avoiding an array of negative health outcomes associated with non-use. Increasingly, the potential users of these limbs are the focus of commercial prosthetic company advertisements. It has been argued that it is important to examine such media representations, not least because people's beliefs regarding health and illness are often forged from the discourses and constructions available to them in such material, but because these representations mediate individual lived experience. This article provides a thematic analysis, drawing upon discourse analysis and semiotics, of textual-pictorial representations of artificial limb users in the advertisements of prosthetic companies. The data set was comprised of advertisements that appeared over a 2-year period in inMotion, an international magazine produced and distributed by a major amputee advocacy group. The findings indicate that dominant societal constructions of work, gender and family are drawn on in depicting artificial limb users. These offer generally positive representations that draw on socially pervasive stereotypes. The findings are discussed in relation to literature concerning the experience and meaning of prosthesis use, and the implications for health professionals working with this group are set out. Implications for Rehabilitation People who lose a limb are increasingly being exposed to advertisements from prosthetic companies. Such advertisements have the potential to foster unrealistic expectations regarding rehabilitation following amputation. Healthcare professionals need to be mindful of how these advertisements mediate lived experience and impact on rehabilitation when planning personal care plans.

  20. Optical fiber Bragg grating-instrumented silicone liner for interface pressure measurement within prosthetic sockets of lower-limb amputees

    NASA Astrophysics Data System (ADS)

    Al-Fakih, Ebrahim; Arifin, Nooranida; Pirouzi, Gholamhossein; Mahamd Adikan, Faisal Rafiq; Shasmin, Hanie Nadia; Abu Osman, Noor Azuan

    2017-08-01

    This paper presents a fiber Bragg grating (FBG)-instrumented prosthetic silicone liner that provides cushioning for the residual limb and can successfully measure interface pressures inside prosthetic sockets of lower-limb amputees in a simple and practical means of sensing. The liner is made of two silicone layers between which 12 FBG sensors were embedded at locations of clinical interest. The sensors were then calibrated using a custom calibration platform that mimics a real-life situation. Afterward, a custom gait simulating machine was built to test the liner performance during an amputee's simulated gait. To validate the findings, the results were compared to those obtained by the commonly used F-socket mats. As the statistical findings reveal, both pressure mapping methods measured the interface pressure in a consistent way, with no significant difference (P-values ≥0.05). This pressure mapping technique in the form of a prosthetic liner will allow prosthetics professionals to quickly and accurately create an overall picture of the interface pressure distribution inside sockets in research and clinical settings, thereby improving the socket fit and amputee's satisfaction.

  1. Injectible bodily prosthetics employing methacrylic copolymer gels

    DOEpatents

    Mallapragada, Surya K.; Anderson, Brian C.

    2007-02-27

    The present invention provides novel block copolymers as structural supplements for injectible bodily prosthetics employed in medical or cosmetic procedures. The invention also includes the use of such block copolymers as nucleus pulposus replacement materials for the treatment of degenerative disc disorders and spinal injuries. The copolymers are constructed by polymerization of a tertiary amine methacrylate with either a (poly(ethylene oxide)-b-poly(propylene oxide)-b-poly(ethylene oxide) polymer, such as the commercially available Pluronic.RTM. polymers, or a poly(ethylene glycol) methyl ether polymer.

  2. Oral health-related quality of life after prosthetic rehabilitation: a longitudinal study with the OHIP questionnaire.

    PubMed

    Jenei, Ágnes; Sándor, János; Hegedűs, Csaba; Bágyi, Kinga; Nagy, László; Kiss, Csongor; Szabó, Gyula; Márton, Ildikó J

    2015-07-10

    Aspects of oral health related quality of life (OHRQoL) attracted an increased attention recently. The aim of the study was to assess self-reported oral health related quality of life (OHRQoL) among patients requiring prosthetic rehabilitation and to determine the rate of improvement 1 month and 6-12 months after therapy. In addition, effect of age, gender, oral health indicators and denture types before treatment were assessed on OHRQoL as evaluated and reported by the patients. Hungarian version of OHIP-49 (OHIP-49-H) questionnaire was completed before oral rehabilitation (T0-phase) by 389 patients undergoing prosthetic replacement. After 1 month (T1-phase) and 6-12 months (T2-phase) recall periods 235 and 92 patients completed the questionnaire. The median interquartile range (IQR) values of the total OHIP-49-H score were calculated for T0-, T1- and T2-phases. Reliability of the questionnaire was checked by Cronbach's statistics. Age, gender, oral health indicators and denture types of patients before and after treatment were recorded and treatment-associated changes in OHRQoL were evaluated. The study demonstrated the excellent reliability and internal consistency of OHIP-49-H by a high and narrow range of Cronbach's alpha value (0.81-0.93). A median OHIP-49-H score of 52; IQR = 25-83 demonstrated a poor OHRQoL on first admission. Decreasing median total OHIP-49-H scores 1 month (24; IQR = 9-51; p < 0.001) and 6-12 months (20; IQR = 7-37; p = 0,055) after therapy indicated an improvement of OHRQoL. Patients' age and CPI value assessed before treatment proved to be significant factors of OHRQoL. Here we presented representative data about self-assessed OHRQoL of patients requiring prosthetic treatment from Hungary using OHIP-49-H questionnaire. The results demonstrated that the restoration of oral health was associated with an improvement in patients' OHRQoL. According to the demographical and T0 phase clinical status, the treatment was more

  3. The comparison of transfemoral amputees using mechanical and microprocessor- controlled prosthetic knee under different walking speeds: A randomized cross-over trial.

    PubMed

    Cao, Wujing; Yu, Hongliu; Zhao, Weiliang; Meng, Qiaoling; Chen, Wenming

    2018-04-20

    The microprocessor-controlled prosthetic knees have been introduced to transfemoral amputees due to advances in biomedical engineering. A body of scientific literature has shown that the microprocessor-controlled prosthetic knees improve the gait and functional abilities of persons with transfemoral amputation. The aim of this study was to propose a new microprocessor-controlled prosthetic knee (MPK) and compare it with non-microprocessor-controlled prosthetic knees (NMPKs) under different walking speeds. The microprocessor-controlled prosthetic knee (i-KNEE) with hydraulic damper was developed. The comfortable self-selected walking speeds of 12 subjects with i-KNEE and NMPK were obtained. The maximum swing flexion knee angle and gait symmetry were compared in i-KNEE and NMPK condition. The comfortable self-selected walking speeds of some subjects were higher with i-KNEE while some were not. There was no significant difference in comfortable self-selected walking speed between the i-KNEE and the NMPK condition (P= 0.138). The peak prosthetic knee flexion during swing in the i-KNEE condition was between sixty and seventy degree under any walking speed. In the NMPK condition, the maximum swing flexion knee angle changed significantly. And it increased with walking speed. There is no significant difference in knee kinematic symmetry when the subjects wear the i-KNEE or NMPK. The results of this study indicated that the new microprocessor-controlled prosthetic knee was suitable for transfemoral amputees. The maximum swing flexion knee angle under different walking speeds showed different properties in the NMPK and i-KNEE condition. The i-KNEE was more adaptive to speed changes. There was little difference of comfortable self-selected walking speed between i-KNEE and NMPK condition.

  4. Factors influencing workplace health promotion intervention: a qualitative systematic review.

    PubMed

    Rojatz, Daniela; Merchant, Almas; Nitsch, Martina

    2017-10-01

    Although workplace health promotion (WHP) has evolved over the last 40 years, systematically collected knowledge on factors influencing the functioning of WHP is scarce. Therefore, a qualitative systematic literature review was carried out to systematically identify and synthesize factors influencing the phases of WHP interventions: needs assessment, planning, implementation and evaluation. Research evidence was identified by searching electronic databases (Scopus, PubMed, Social Sciences Citation Index, ASSIA, ERIC, IBBS and PsycINFO) from 1998 to 2013, as well as by cross-checking reference lists of included peer-reviewed articles. The inclusion criteria were: original empirical research, description of WHP, description of barriers to and/or facilitators of the planning, implementation and/or evaluation of WHP. Finally, 54 full texts were included. From these, influencing factors were extracted and summarized using thematic analysis. The majority of influencing factors referred to the implementation phase, few dealt with planning and/or evaluation and none with needs assessment. The influencing factors were condensed into topics with respect to factors at contextual level (e.g. economic crisis); factors at organizational level (e.g. management support); factors at intervention level (e.g. quality of intervention concept); factors at implementer level (e.g. resources); factors at participant level (e.g. commitment to intervention) and factors referring to methodological and data aspects (e.g. data-collection issues). Factors regarding contextual issues and organizational aspects were identified across three phases. Therefore, future research and practice should consider not only the influencing factors at different levels, but also at different phases of WHP interventions. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  5. [Guided and computer-assisted implant surgery and prosthetic: The continuous digital workflow].

    PubMed

    Pascual, D; Vaysse, J

    2016-02-01

    New continuous digital workflow protocols of guided and computer-assisted implant surgery improve accuracy of implant positioning. The design of the future prosthesis is based on the available prosthetic space, gingival height and occlusal relationship with the opposing and adjacent teeth. The implant position and length depend on volume, density and bone quality, gingival height, tooth-implant and implant-implant distances, implant parallelism, axis and type of the future prosthesis. The crown modeled on the software will therefore serve as a guide to the future implant axis and not the reverse. The guide is made by 3D printing. The software determines surgical protocol with the drilling sequences. The unitary or plural prosthesis, modeled on the software and built before surgery, is loaded directly after implant placing, if needed. These protocols allow for a full continuity of the digital workflow. The software provides the surgeon and the dental technician a total freedom for the prosthetic-surgery guide design and the position of the implants. The prosthetic project, occlusal and aesthetic, taking the bony and surgical constraints into account, is optimized. The implant surgery is simplified and becomes less "stressful" for the patient and the surgeon. Guided and computer-assisted surgery with continuous digital workflow is becoming the technique of choice to improve the accuracy and quality of implant rehabilitation. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  6. Biologically inspired multi-layered synthetic skin for tactile feedback in prosthetic limbs.

    PubMed

    Osborn, Luke; Nguyen, Harrison; Betthauser, Joseph; Kaliki, Rahul; Thakor, Nitish

    2016-08-01

    The human body offers a template for many state-of-the-art prosthetic devices and sensors. In this work, we present a novel, sensorized synthetic skin that mimics the natural multi-layered nature of mechanoreceptors found in healthy glabrous skin to provide tactile information. The multi-layered sensor is made up of flexible piezoresistive textiles that act as force sensitive resistors (FSRs) to convey tactile information, which are embedded within a silicone rubber to resemble the compliant nature of human skin. The top layer of the synthetic skin is capable of detecting small loads less than 5 N whereas the bottom sensing layer responds reliably to loads over 7 N. Finite element analysis (FEA) of a simplified human fingertip and the synthetic skin was performed. Results suggest similarities in behavior during loading. A natural tactile event is simulated by loading the synthetic skin on a prosthetic limb. Results show the sensors' ability to detect applied loads as well as the ability to simulate neural spiking activity based on the derivative and temporal differences of the sensor response. During the tactile loading, the top sensing layer responded 0.24 s faster than the bottom sensing layer. A synthetic biologically-inspired skin such as this will be useful for enhancing the functionality of prosthetic limbs through tactile feedback.

  7. Development of an externally powered prosthetic hook for amputees

    NASA Technical Reports Server (NTRS)

    Karchak, A., Jr.; Allen, J. R.; Bontrager, E. L.

    1973-01-01

    The powered hook with trigger finger appears to be a useful adaptation of a terminal device for an amputee when performing vocational activities involving the use of a powered tool requiring a trigger control. The proportional control system includes transducers and amplifiers and appears to have widespread application for control of any external power, whether it be in the orthotic or prosthetic field.

  8. Factors that influence nurses' customer orientation.

    PubMed

    Darby, D N; Daniel, K

    1999-09-01

    Hospital care mostly involves complex processes that are continuously adjusted to match individual client needs. As most patients cannot evaluate the technology used, they focus on personal interactions with care providers when making judgements about the care received. Nurses are the care team members that primarily provide ongoing care. This study aims to further understand factors that influence the way nursing staff relate to their patients. A model is presented of the contextual and self-perceptual factors that influence the level of customer/client orientation of nursing services in an Australian hospital setting along with details of a quantitative study. Nurses completed an anonymous questionnaire, which was then mailed directly to the researchers. Analysis of the data included factor analysis, regression and path analysis. The results show that contextual elements such as management commitment to service quality and self-perceptual factors such as role stress impact on the nurses' client service orientation. However, the variables being studied commonly have both direct and indirect effects with feelings about commitment to the organization having a notable mediating influence. The scales adapted from use in other industries are able to measure the perceptual and outcome variables in a health institutional setting. The managerial implications are that both a comprehensive programme of organizational culture and individual staff member development is needed if an enhanced customer orientation and the consequent improvement in client satisfaction with nursing care is to occur.

  9. Neural-Network Control Of Prosthetic And Robotic Hands

    NASA Technical Reports Server (NTRS)

    Buckley, Theresa M.

    1991-01-01

    Electronic neural networks proposed for use in controlling robotic and prosthetic hands and exoskeletal or glovelike electromechanical devices aiding intact but nonfunctional hands. Specific to patient, who activates grasping motion by voice command, by mechanical switch, or by myoelectric impulse. Patient retains higher-level control, while lower-level control provided by neural network analogous to that of miniature brain. During training, patient teaches miniature brain to perform specialized, anthropomorphic movements unique to himself or herself.

  10. Corynebacterium Prosthetic Joint Infection

    PubMed Central

    Cazanave, Charles; Greenwood-Quaintance, Kerryl E.; Hanssen, Arlen D.

    2012-01-01

    Identification of Corynebacterium species may be challenging. Corynebacterium species are occasional causes of prosthetic joint infection (PJI), but few data are available on the subject. Based on the literature, C. amycolatum, C. aurimucosum, C. jeikeium, and C. striatum are the most common Corynebacterium species that cause PJI. We designed a rapid PCR assay to detect the most common human Corynebacterium species, with a specific focus on PJI. A polyphosphate kinase gene identified using whole-genome sequence was targeted. The assay differentiates the antibiotic-resistant species C. jeikeium and C. urealyticum from other species in a single assay. The assay was applied to a collection of human Corynebacterium isolates from multiple clinical sources, and clinically relevant species were detected. The assay was then tested on Corynebacterium isolates specifically associated with PJI; all were detected. We also describe the first case of C. simulans PJI. PMID:22337986

  11. Influence of surgical and prosthetic techniques on marginal bone loss around titanium implants. Part I: immediate loading in fresh extraction sockets.

    PubMed

    Berberi, Antoine N; Tehini, Georges E; Noujeim, Ziad F; Khairallah, Alexandre A; Abousehlib, Moustafa N; Salameh, Ziad A

    2014-10-01

    Delayed placement of implant abutments has been associated with peri-implant marginal bone loss; however, long-term results obtained by modifying surgical and prosthetic techniques after implant placement are still lacking. This study aimed to evaluate the marginal bone loss around titanium implants placed in fresh extraction sockets using two loading protocols after a 5-year follow-up period. A total of 36 patients received 40 titanium implants (Astra Tech) intended for single-tooth replacement. Implants were immediately placed into fresh extraction sockets using either a one-stage (immediate loading by placing an interim prosthesis into functional occlusion) or a two-stage prosthetic loading protocol (insertion of abutments after 8 weeks of healing time). Marginal bone levels relative to the implant reference point were evaluated at four time intervals using intraoral radiographs: at time of implant placement, and 1, 3, and 5 years after implant placement. Measurements were obtained from mesial and distal surfaces of each implant (α = 0.05). One-stage immediate implant placement into fresh extraction sockets resulted in a significant reduction in marginal bone loss (p < 0.002) compared to the traditional two-stage technique. Whereas mesial surfaces remained stable for the 5-year observation period, significant marginal bone loss was observed on distal surfaces of implants after cementation of interim prostheses (p < 0.007) and after 12 months (p < 0.034). Within the limitations of this study, immediate loading of implants placed into fresh extraction sockets reduced marginal bone loss and did not compromise the success rate of the restorations. © 2014 by the American College of Prosthodontists.

  12. Update on Bioactive Prosthetic Material for the Treatment of Hernias.

    PubMed

    Edelman, David S; Hodde, Jason P

    2011-12-01

    The use of mesh in the repair of hernias is commonplace. Synthetic mesh, like polypropylene, has been the workhorse for hernia repairs since the 1980s. Surgisis® mesh (Cook Surgical, Bloomington, IN), a biologic hernia graft material composed of purified porcine small intestinal submucosa (SIS), was first introduced to the United States in 1998 as an alternative to synthetic mesh materials. This mesh, composed of extracellular matrix collagen, fibronectin and associated glycosaminoglycans and growth factors, has been extensively investigated in animal models and used clinically in many types of surgical procedures. SIS acts as a scaffold for natural growth and strength. We reported our initial results in this publication in July 2006. Since then, there have been many more reports and numerous other bioactive prosthetic materials (BPMs) released. The object of this article is to briefly review some of the current literature on the use of BPM for inguinal hernias, sports hernias, and umbilical hernias.

  13. Consideration of Real World Factors Influencing Greenhouse ...

    EPA Pesticide Factsheets

    Discuss a variety of factors that influence the simulated fuel economy and GHG emissions that are often overlooked and updates made to ALPHA based on actual benchmarking data observed across a range of vehicles and transmissions. ALPHA model calibration is also examined, focusing on developing generic calibrations for driver behavior, transmission gear selection and torque converter lockup. In addition, show the derivation of correction factors needed to estimate cold start emission results. To provide an overview of the ALPHA tool with additional focus on recent updates by presenting the approach for validating and calibrating ALPHA to match particular vehicles in a general sense, then by looking at the individual losses, and calibration factors likely to influence fuel economy.

  14. Technetium-99m-labeled annexin V imaging for detecting prosthetic joint infection in a rabbit model.

    PubMed

    Tang, Cheng; Wang, Feng; Hou, Yanjie; Lu, Shanshan; Tian, Wei; Xu, Yan; Jin, Chengzhe; Wang, Liming

    2015-05-01

    Accurate and timely diagnosis of prosthetic joint infection is essential to initiate early treatment and achieve a favorable outcome. In this study, we used a rabbit model to assess the feasibility of technetium-99m-labeled annexin V for detecting prosthetic joint infection. Right knee arthroplasty was performed on 24 New Zealand rabbits. After surgery, methicillin-susceptible Staphylococcus aureus was intra-articularly injected to create a model of prosthetic joint infection (the infected group, n = 12). Rabbits in the control group were injected with sterile saline (n = 12). Seven and 21 days after surgery, technetium-99m-labeled annexin V imaging was performed in 6 rabbits of each group. Images were acquired 1 and 4 hours after injection of technetium-99m-labeled annexin V (150 MBq). The operated-to-normal-knee activity ratios were calculated for quantitative analysis. Seven days after surgery, increased technetium-99m-labeled annexin V uptake was observed in all cases. However, at 21 days a notable decrease was found in the control group, but not in the infected group. The operated-to-normal-knee activity ratios of the infected group were 1.84 ± 0.29 in the early phase and 2.19 ± 0.34 in the delay phase, both of which were significantly higher than those of the control group (P = 0.03 and P = 0.02). The receiver operator characteristic curve analysis showed that the operated-to-normal-knee activity ratios of the delay phase at 21 days was the best indicator, with an accuracy of 80%. In conclusion, technetium-99m-labeled annexin V imaging could effectively distinguish an infected prosthetic joint from an uninfected prosthetic joint in a rabbit model.

  15. What factors influence British medical students' career intentions?

    PubMed

    Ibrahim, Michael; Fanshawe, Angela; Patel, Vanash; Goswami, Karan; Chilvers, Geoffrey; Ting, Michelle; Pilavakis, Yiannis; Rao, Christopher; Athanasiou, Thanos

    2014-12-01

    The aim of this study was to identify factors that influence career choice in UK medical students. Students at seven institutions were invited to rate how important various factors were on influencing their career choices and how interested they were in pursuing different specialties. The influence of interpersonal relationship networks on career choice was also evaluated. 641 responses were collected. 44% (283) were male, 16% (105) were graduates and 41% (263) were final-year students. For Dermatology (p = 0.009), Paediatrics (p = 0.000), Radiology (p = 0.000), Emergency Medicine (p = 0.018) and Cardiothoracic Surgery (p = 0.000), there was a clear correlation between completing a clinical attachment and an interest in pursuing the specialty. Perceived characteristics of the speciality, individually and in clusters were considered important by specific subgroups of students, such as those interested in surgery. These students considered prestige (p = 0.0003), role models (p = 0.014), financial rewards after training (p = 0.0196) and technical challenge (p = 0.0011) as important factors. Demographics such as sex and age played a significant role in career choice. Interpersonal relationship networks do not have a significant influence on career intentions. This study shows that the career intentions of British medical students are influenced by their undergraduate experience and by the weight they place on different specialty-related factors.

  16. Are prosthetic heart valve fibrin strands negligible? The associations and significance.

    PubMed

    Kiavar, Majid; Sadeghpour, Anita; Bakhshandeh, Hooman; Tayyebi, Parisa; Bassiri, Hossein Ali; Esmaeilzadeh, Maryam; Maleki, Majid; Noohi, Feridoun

    2009-08-01

    Filamentous fibrin strands (FSs) attached to valve prostheses have been well described in patients undergoing transesophageal echocardiography, but the frequency and clinical significance of these strands remain poorly defined. The aims of this study were to determine the frequency of prosthetic valve strands and to assess their significance in relation to clinical cerebral ischemic events (CIEs) and anticoagulant status. Three hundred consecutive patients with 421 prosthetic heart valves were evaluated for the presence of FSs (highly mobile, filamentous masses<1 mm thick). FSs were found in 139 patients (49%) and 147 prostheses (38%) in patients with left-sided prostheses, with a significant association between FSs, CIEs, and anticoagulant status (P<.001). A lower international normalized ratio (<2.5) had a positive association with the occurrence of CIEs. There is a significant association between FSs, CIEs, and patient's anticoagulant status; therefore, aggressive anticoagulation and close follow-up are recommended for these patients.

  17. Evaluation of prosthetic valve thrombosis by 64-row multi-detector computed tomography. .

    PubMed

    Tarzia, Vincenzo; Bortolussi, Giacomo; Rubino, Maurizio; Gallo, Michele; Bottio, Tomaso; Gerosa, Gino

    2015-03-01

    Multi-detector computed tomography (MDCT), combined with retrospective electrocardiographic gating, permits cardiac imaging with high accuracy. Recent advances in MDCT have seemed to respond adequately to the need for a non-invasive and reliable assessment of the coronary artery lumen. Two patients with prosthetic aortic valves (one bioprosthetic, one mechanical) presented at the authors' institution with dyspnea and syncopal episodes. MDCT was performed to evaluate thrombus characteristics and exclude coronary artery disease (CAD). Based on the MDCT coronary artery assessment, neither patient underwent preoperative invasive coronary angiography, abolishing the risk of any iatrogenic thrombus fragmentation and subsequent embolization. One patient underwent surgical treatment without complications, while medical therapy was successful in the other case. MDCT can be used for the accurate imaging of thrombi on prosthetic aortic valves, and to correctly assess possible CAD.

  18. Power feasibility of implantable digital spike-sorting circuits for neural prosthetic systems.

    PubMed

    Zumsteg, Zachary S; Ahmed, Rizwan E; Santhanam, Gopal; Shenoy, Krishna V; Meng, Teresa H

    2004-01-01

    A new class of neural prosthetic systems aims to assist disabled patients by translating cortical neural activity into control signals for prosthetic devices. Based on the success of proof-of-concept systems in the laboratory, there is now considerable interest in increasing system performance and creating implantable electronics for use in clinical systems. A critical question that impacts system performance and the overall architecture of these systems is whether it is possible to identify the neural source of each action potential (spike sorting) in real-time and with low power. Low power is essential both for power supply considerations and heat dissipation in the brain. In this paper we report that several state-of-the-art spike sorting algorithms implemented in modern CMOS VLSI processes are expected to be power realistic.

  19. Hybrid nanostructured coating for increased resistance of prosthetic devices to staphylococcal colonization

    NASA Astrophysics Data System (ADS)

    Anghel, Ion; Grumezescu, Alexandru Mihai

    2013-01-01

    Prosthetic medical device-associated infections are responsible for significant morbidity and mortality rates. Novel improved materials and surfaces exhibiting inappropriate conditions for microbial development are urgently required in the medical environment. This study reveals the benefit of using natural Mentha piperita essential oil, combined with a 5 nm core/shell nanosystem-improved surface exhibiting anti-adherence and antibiofilm properties. This strategy reveals a dual role of the nano-oil system; on one hand, inhibiting bacterial adherence and, on the other hand, exhibiting bactericidal effect, the core/shell nanosystem is acting as a controlled releasing machine for the essential oil. Our results demonstrate that this dual nanobiosystem is very efficient also for inhibiting biofilm formation, being a good candidate for the design of novel material surfaces used for prosthetic devices.

  20. Progress Toward Optimizing Prosthetic Socket Fit and Suspension Using Elevated Vacuum to Promote Residual Limb Health.

    PubMed

    Wernke, Matthew M; Schroeder, Ryan M; Haynes, Michael L; Nolt, Lonnie L; Albury, Alexander W; Colvin, James M

    2017-07-01

    Objective: Prosthetic sockets are custom made for each amputee, yet there are no quantitative tools to determine the appropriateness of socket fit. Ensuring a proper socket fit can have significant effects on the health of residual limb soft tissues and overall function and acceptance of the prosthetic limb. Previous work found that elevated vacuum pressure data can detect movement between the residual limb and the prosthetic socket; however, the correlation between the two was specific to each user. The overall objective of this work is to determine the relationship between elevated vacuum pressure deviations and prosthetic socket fit. Approach: A tension compression machine was used to apply repeated controlled forces onto a residual limb model with sockets of different internal volume. Results: The vacuum pressure-displacement relationship was dependent on socket fit. The vacuum pressure data were sensitive enough to detect differences of 1.5% global volume and can likely detect differences even smaller. Limb motion was reduced as surface area of contact between the limb model and socket was maximized. Innovation: The results suggest that elevated vacuum pressure data provide information to quantify socket fit. Conclusions: This study provides evidence that the use of elevated vacuum pressure data may provide a method for prosthetists to quantify and monitor socket fit. Future studies should investigate the relationship between socket fit, limb motion, and limb health to define optimal socket fit parameters.

  1. Environmental influences: factors influencing a woman's decision to use dietary supplements.

    PubMed

    Conner, Mark; Kirk, Sara F L; Cade, Janet E; Barrett, Jennifer H

    2003-06-01

    Use of dietary supplements by women, particularly those over 40 years of age may be widespread in the United Kingdom. However, from surveillance data, there appears to be a disparity between nutrition and health needs and the rationale for and actual use of dietary supplements by women. This apparent paradox forms the basis for an inverse supplement hypothesis (i.e., supplement use in women appears to be most prevalent among those with least need). Little research has been done to examine the factors underlying the decision to use dietary supplements. Reasons for consuming dietary supplements are often complex, combining social, psychological, knowledge and economic factors. The theory of planned behavior is a widely used model for assessing factors influencing behavioral motivation and action that may be useful for assessing specific diet- and nutrition-related practices. It provided the basis for the development of a questionnaire to explore overall dietary supplement use in a cohort of women in the United Kingdom. The analysis of factors related to beliefs underlying dietary supplement use revealed differences between supplement users and nonusers. Differences included a stronger belief by users than nonusers that taking dietary supplements ensures against possible ill health. Both users and nonusers of supplements also perceived the media (books and magazines) to be a powerful influence on a person's decision to use supplements. These findings highlight the potential of the theory of planned behavior in exploring supplement-taking behavior while throwing light on the factors influencing an individual's motivations to use dietary supplements.

  2. Uncovering Factors Influencing Interpersonal Health Communication

    PubMed Central

    Donné, Lennie; Jansen, Carel; Hoeks, John

    2017-01-01

    Talking to friends, family, or peers about health issues might, among other things, increase knowledge of social norms and feelings of self-efficacy in adopting a healthier lifestyle. We often see interpersonal health communication as an important mediating factor in the effects of health campaigns on health behavior. No research has been done so far, however, on factors that influence whether and how people talk about health issues without being exposed to a health campaign first. In this exploratory study, we interviewed 12 participants about their communication behavior concerning six different health themes, like smoking and exercising. The results suggest that at least four types of interpersonal health communication can be distinguished, each influenced by different factors, like conversational partner and objective of the conversation. Future research should take this diversity of interpersonal health communication into account, and focus on designing health campaigns that aim to trigger dialogue within target populations. PMID:28660238

  3. Propionibacterium avidum as an Etiological Agent of Prosthetic Hip Joint Infection

    PubMed Central

    Brüggemann, Holger; Scholz, Christian F. P.; Leimbach, Andreas; Söderquist, Bo

    2016-01-01

    Propionibacterium acnes is well-established as a possible etiologic agent of prosthetic joint infections (PJIs). Other Propionibacterium spp. have occasionally been described as a cause of PJIs, but this has not previously been the case for P. avidum despite its capacity to form biofilm. We describe two patients with prosthetic hip joint infections caused by P. avidum. Both patients were primarily operated with an anteriorly curved skin incision close to the skin crease of the groin, and both were obese. Initial treatment was performed according to the DAIR procedure (debridement, antibiotics, and implant retention). In case 1, the outcome was successful, but in case 2, a loosening of the cup was present 18 months post debridement. The P. avidum isolate from case 1 and two isolates from case 2 (obtained 18 months apart) were selected for whole genome sequencing. The genome of P. avidum obtained from case 1 was approximately 60 kb larger than the genomes of the two isolates of case 2. These latter isolates were clonal with the exception of SNPs in the genome. All three strains possessed the gene cluster encoding exopolysaccharide synthesis. P. avidum has a pathogenic potential and the ability to cause clinically relevant infections, including abscess formation, in the presence of foreign bodies such as prosthetic joint components. Skin incision in close proximity to the groin or deep skin crease, such as the anteriorly curved skin incision approach, might pose a risk of PJIs by P. avidum, especially in obese patients. PMID:27355425

  4. Hierarchical and coupling model of factors influencing vessel traffic flow.

    PubMed

    Liu, Zhao; Liu, Jingxian; Li, Huanhuan; Li, Zongzhi; Tan, Zhirong; Liu, Ryan Wen; Liu, Yi

    2017-01-01

    Understanding the characteristics of vessel traffic flow is crucial in maintaining navigation safety, efficiency, and overall waterway transportation management. Factors influencing vessel traffic flow possess diverse features such as hierarchy, uncertainty, nonlinearity, complexity, and interdependency. To reveal the impact mechanism of the factors influencing vessel traffic flow, a hierarchical model and a coupling model are proposed in this study based on the interpretative structural modeling method. The hierarchical model explains the hierarchies and relationships of the factors using a graph. The coupling model provides a quantitative method that explores interaction effects of factors using a coupling coefficient. The coupling coefficient is obtained by determining the quantitative indicators of the factors and their weights. Thereafter, the data obtained from Port of Tianjin is used to verify the proposed coupling model. The results show that the hierarchical model of the factors influencing vessel traffic flow can explain the level, structure, and interaction effect of the factors; the coupling model is efficient in analyzing factors influencing traffic volumes. The proposed method can be used for analyzing increases in vessel traffic flow in waterway transportation system.

  5. Factors Influencing College Science Success

    ERIC Educational Resources Information Center

    Tai, Robert H.; Sadler, Philip M.; Mintzes, Joel J.

    2006-01-01

    In this paper, the authors report some of the salient findings of a large-scale, four-year national study, conducted at the Harvard-Smithsonian Center for Astrophysics, entitled "Factors Influencing College Science Success" (FICSS), which surveyed college students who enrolled in first-year biology, chemistry, and physics courses…

  6. Assessment of Factors Influencing Communication in Clinical Pharmacy.

    PubMed

    Yao, Dongning; Jiang, Liang; Huang, Yuankai; Chen, Lei; Wang, Yitao; Xi, Xiaoyu

    2018-01-01

    This study aimed to identify and assess the factors that influence communication quality between clinical pharmacists and patients using a structural equation model based on the predisposing, reinforcing, and enabling constructs in educational/environmental diagnosis and evaluation-policy, regulatory, and organizational constructs in educational and ecological development model to identify the most effective path to increase their communication quality. A survey was conducted at 253 Class-A tertiary hospitals in China from March to December 2016. During on-site observations, verbal communications between clinical pharmacists ( n = 752) and patients were audio recorded, and communication quality was rated by an expert panel on an 8-item Quality of Communication Rating Scale. Clinical pharmacists completed questionnaires that examined the predisposing, enabling, and reinforcing factors that influenced communication quality. Finally, AMOS was employed to examine the relationships between the three factors and communication quality. The results indicated that all three factors positively affected communication quality, with correlation coefficients of .26, .13, and .17, respectively. The most influential predisposing factor was attitude (.77), the most influential enabling factors were self-efficacy (.71) and confidence (.72), and the most influential reinforcing factor was rewards (.74). The findings suggest that pharmacists' attitudes toward, perceived knowledge of, and skill and confidence in communication, and the rewards offered by pharmacy management are the most influential factors that influence communication quality.

  7. Optical fiber Bragg grating-instrumented silicone liner for interface pressure measurement within prosthetic sockets of lower-limb amputees.

    PubMed

    Al-Fakih, Ebrahim; Arifin, Nooranida; Pirouzi, Gholamhossein; Mahamd Adikan, Faisal Rafiq; Shasmin, Hanie Nadia; Abu Osman, Noor Azuan

    2017-08-01

    This paper presents a fiber Bragg grating (FBG)-instrumented prosthetic silicone liner that provides cushioning for the residual limb and can successfully measure interface pressures inside prosthetic sockets of lower-limb amputees in a simple and practical means of sensing. The liner is made of two silicone layers between which 12 FBG sensors were embedded at locations of clinical interest. The sensors were then calibrated using a custom calibration platform that mimics a real-life situation. Afterward, a custom gait simulating machine was built to test the liner performance during an amputee's simulated gait. To validate the findings, the results were compared to those obtained by the commonly used F-socket mats. As the statistical findings reveal, both pressure mapping methods measured the interface pressure in a consistent way, with no significant difference (P-values ≥0.05). This pressure mapping technique in the form of a prosthetic liner will allow prosthetics professionals to quickly and accurately create an overall picture of the interface pressure distribution inside sockets in research and clinical settings, thereby improving the socket fit and amputee's satisfaction. (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).

  8. Factors influencing the implementation of evidence in Chinese nursing practice.

    PubMed

    Cheng, Lei; Broome, Marion E; Feng, Sheng; Hu, Yan

    2017-12-01

    To explore the influencing factors from staff nurses, nurse managers, nursing directors and a physician involved in nursing evidence implementation in Mainland China. Although the need for evidence-based nursing is well recognised, continuous efforts are needed to strive for closing the gap from evidence to action. Previous studies have explored influencing factors from individual and organisational perspectives in Western countries. However, it remains unclear what the influences (i.e., context and culture) in the developing countries as China. A grounded theory design using in-depth individual interviews was conducted. Interviews with 56 participants from 24 evidence-based nursing implementation projects were conducted in Mainland China. Constant comparative analysis was used to discover the concepts describing the influencing factors during the implementation process. Factors that influenced implementation of evidence-based practice in the Chinese context were identified. These included the leaders of the projects, the nature of the evidence, practising nurses, patients involved in the projects, the system where the projects were implemented, as well as the influence from outside of the system. A variety of factors influencing evidence implementation in Chinese nursing context were identified and further explored from the perspective of different project leaders and culture influence. There is apparently a strong demand for a supportive system, targeted strategies to facilitate various evidence implementations and integrated core elements of evidence-based practice at the point care. The blurred boundaries and complexity of influencing factors call for a systematic and dynamic perspective during implementation. The competitive priorities emphasise the importance of integration between clinical nursing care and evidence-based practice. © 2017 John Wiley & Sons Ltd.

  9. Prosthetic Complications and Maintenance Requirements in Locator-attached Implant-Supported Overdentures: A Retrospective Study.

    PubMed

    Engelhardt, Frank; Zeman, Florian; Behr, Michael; Hahmel, Sebastian

    2016-03-01

    Retrospective data of 32 patients supplied with implant-supported and Locator-attached overdentures were screened for prosthetic complications and maintenance requirements, which were recorded and statistically analyzed. Mean observation time was 4.78 ± 1.72) years. Loss of retention was the most frequently observed event (n = 22). Damage and exchange of the insert holders (n = 4) and loosening of locator attachments (n = 2) and fracture of the insert holder (n = 2) were uncommon events; no loss of locator attachments was observed. Loss of retention in Locator-attached overdentures is frequent; correlating patient-specific parameters with prosthetic complications is necessary to define recommendations for the use of Locator attachments.

  10. INTERVENTIONS TO MANAGE RESIDUAL LIMB ULCERATION DUE TO PROSTHETIC USE IN INDIVIDUALS WITH LOWER EXTREMITY AMPUTATION: A SYSTEMATIC REVIEW OF THE LITERATURE.

    PubMed

    Highsmith, M Jason; Kahle, Jason T; Klenow, Tyler D; Andrews, Casey R; Lewis, Katherine L; Bradley, Rachel C; Ward, Jessica M; Orriola, John J; Highsmith, James T

    2016-09-01

    Patients with lower extremity amputation (LEA) experience 65% more dermatologic issues than non-amputees, and skin problems are experienced by ≈75% of LEA patients who use prostheses. Continuously referring LEA patients to a dermatologist for every stump related skin condition may be impractical. Thus, physical rehabilitation professionals should be prepared to recognize and manage common non-emergent skin conditions in this population. The purpose of this study was to determine the quantity, quality, and strength of available evidence supporting treatment methods for prosthesis-related residual limb (RL) ulcers. Systematic literature review with evidence grading and synthesis of empirical evidence statements (EES) was employed. Three EESs were formulated describing ulcer etiology, conditions in which prosthetic continuance is practical, circumstances likely requiring prosthetic discontinuance, and the consideration of additional medical or surgical interventions. Continued prosthetic use is a viable option to manage minor or early-stage ulcerated residual limbs in compliant patients lacking multiple comorbidities. Prosthetic discontinuance is also a viable method of residual limb ulcer healing and may be favored in the presence of severe acute ulcerations, chronic heavy smoking, intractable pain, rapid volume and weight change, history of chronic ulceration, systemic infections, or advanced dysvascular etiology. Surgery or other interventions may also be necessary in such cases to achieve restored prosthetic ambulation. A short bout of prosthetic discontinuance with a staged re-introduction plan is another viable option that may be warranted in patients with ulceration due to poor RL volume management. High-quality prospective research with larger samples is needed to determine the most appropriate course of treatment when a person with LEA develops an RL ulcer that is associated with prosthetic use.

  11. Facial recognition using simulated prosthetic pixelized vision.

    PubMed

    Thompson, Robert W; Barnett, G David; Humayun, Mark S; Dagnelie, Gislin

    2003-11-01

    To evaluate a model of simulated pixelized prosthetic vision using noncontiguous circular phosphenes, to test the effects of phosphene and grid parameters on facial recognition. A video headset was used to view a reference set of four faces, followed by a partially averted image of one of those faces viewed through a square pixelizing grid that contained 10x10 to 32x32 dots separated by gaps. The grid size, dot size, gap width, dot dropout rate, and gray-scale resolution were varied separately about a standard test condition, for a total of 16 conditions. All tests were first performed at 99% contrast and then repeated at 12.5% contrast. Discrimination speed and performance were influenced by all stimulus parameters. The subjects achieved highly significant facial recognition accuracy for all high-contrast tests except for grids with 70% random dot dropout and two gray levels. In low-contrast tests, significant facial recognition accuracy was achieved for all but the most adverse grid parameters: total grid area less than 17% of the target image, 70% dropout, four or fewer gray levels, and a gap of 40.5 arcmin. For difficult test conditions, a pronounced learning effect was noticed during high-contrast trials, and a more subtle practice effect on timing was evident during subsequent low-contrast trials. These findings suggest that reliable face recognition with crude pixelized grids can be learned and may be possible, even with a crude visual prosthesis.

  12. Orientation of handle for successful prosthetic treatment in patients with an anatomic compromise after a maxillectomy.

    PubMed

    Sumita, Yuka I; Hattori, Mariko; Elbashti, Mahmoud E; Taniguchi, Hisashi

    2017-05-01

    This clinical technique provides a key procedure for successful prosthetic treatment in patients with an anatomical compromise after a maxillectomy. When making a preliminary impression, the clinician must keep the handle of the stock tray parallel to the patient's interpupillary line extraorally to maintain the correct position of the tray and to make a record of the inclination of the occlusal plane. This simple consideration during this first step of making a preliminary impression can be an important guide for both dentists and dental technicians. Information about the correct positioning of the tray and the inclination of the occlusal plane obtained by using a stock tray handle will greatly reduce the stress experienced by dentists, dental technicians, and patients during the fabrication of the prosthesis and will ultimately lead to successful prosthetic treatment in patients with anatomic compromise resulting from a maxillectomy. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  13. [Factors influencing nurses' organizational citizenship behavior].

    PubMed

    Park, Junhee; Yun, Eunkyung; Han, Sangsook

    2009-08-01

    This study was conducted to identify the factors that influence nurses' organizational citizenship behavior. A cross-sectional design was used, with a convenience sample of 547 nurses from four university hospitals in Seoul and Gyeonggi province. The data were collected through a questionnaire survey done from September 22 to October 10, 2008. The tools used for this study were scales on organizational citizenship behavior (14 items), self-leadership (14 items), empowerment (10 items), organizational commitment (7 items), job satisfaction (8 items) and transformational.transactional leadership (14 items). Cronbach's alpha and factor analysis were examined to test reliability and construct validity of the scale. The data collected were processed using SPSS Window 15.0 Program for actual numbers and percentages, differences in the dependent variable according to general characteristics, and means, standard deviations, correlation coefficients and multiple regression analysis. The factors influencing nurses' organizational citizenship behavior were identified as self-leadership(beta=.247), empowerment (beta=.233), job satisfaction (beta=.209), organizational commitment (beta=.158), and transactional leadership (beta=.142). Five factors explained 42.0% of nurses' organizational citizenship behavior. The results of this study can be used to develop further management strategies for enhancement of nurses' organizational citizenship behavior.

  14. Factors Influencing Title VII Bilingual Program Institutionalization.

    ERIC Educational Resources Information Center

    Lewis, Gerald R.; And Others

    1985-01-01

    This study of the primary restraining and driving forces that influence Title VII bilingual education programs found the external environment, the local community, to be the main factor influencing institutionalization and self-renewal. The internal environment--the local school, and the local school's organization or central office, school board,…

  15. Risk factors and outcomes for nosocomial infection after prosthetic vascular grafts.

    PubMed

    Fariñas, María Carmen; Campo, Ana; Duran, Raquel; Sarralde, José Aurelio; Nistal, Juan Francisco; Gutiérrez-Díez, José Francisco; Fariñas-Álvarez, Concepción

    2017-11-01

    The objective of this study was to determine risk factors for nosocomial infections (NIs) and predictors of mortality in patients with prosthetic vascular grafts (PVGs). This was a prospective cohort study of all consecutive patients who underwent PVG of the abdominal aorta with or without iliac-femoral involvement and peripheral PVG from April 2008 to August 2009 at a university hospital. Patients younger than 15 years and those with severe immunodeficiency were excluded. The follow-up period was until 3 years after surgery or until death. There were 261 patients included; 230 (88.12%) were male, and the mean age was 67.57 (standard deviation, 10.82) years. The reason for operation was aortic aneurysm in 49 (18.77%) patients or lower limb arteriopathy in 212 (81.23%) patients. NIs occurred in 71 (27.20%) patients. Of these, 42 were surgical site infections (SSIs), of which 61.9% occurred in the lower extremities (14 superficial, 10 deep, and 2 PVG infections) and 38.1% in the abdomen (7 superficial, 7 deep, and 2 PVG infections); 15 were respiratory tract infections; and 15 were urinary tract infections. Active lower extremity skin and soft tissue infection (SSTI) at the time of surgery was a significant predictor of NI for both types of PVG (abdominal aortic PVG: adjusted odds ratio [OR], 12.6; 95% confidence interval [CI], 1.15-138.19; peripheral PVG: adjusted OR, 2.43; 95% CI, 1.08-5.47). Other independent predictors of NI were mechanical ventilation (adjusted OR, 55.96; 95% CI, 3.9-802.39) for abdominal aortic PVG and low hemoglobin levels on admission (adjusted OR, 0.84; 95% CI, 0.71-0.99) and emergent surgery (adjusted OR, 4.39; 95% CI, 1.51-12.74) for peripheral PVG. The in-hospital mortality rate was 1.92%. The probability of surviving the first month was 0.96, and significant predictors of mortality were active lower extremity SSTI (adjusted risk ratio [RR], 12.07; 95% CI, 1.04-154.75), high postsurgical glucose levels (adjusted RR, 1.02; 95% CI, 1

  16. Aortic valve insufficiency in the teenager and young adult: the role of prosthetic valve replacement.

    PubMed

    Bradley, Scott M

    2013-10-01

    The contents of this article were presented in the session "Aortic insufficiency in the teenager" at the congenital parallel symposium of the 2013 Society of Thoracic Surgeons (STS) annual meeting. The accompanying articles detail the approaches of aortic valve repair and the Ross procedure.(1,2) The current article focuses on prosthetic valve replacement. For many young patients requiring aortic valve surgery, either aortic valve repair or a Ross procedure provides a good option. The advantages include avoidance of anticoagulation and potential for growth. In other patients, a prosthetic valve is an appropriate alternative. This article discusses the current state of knowledge regarding mechanical and bioprosthetic valve prostheses and their specific advantages relative to valve repair or a Ross procedure. In current practice, young patients requiring aortic valve surgery frequently undergo valve replacement with a prosthetic valve. In STS adult cardiac database, among patients ≤30 years of age undergoing aortic valve surgery, 34% had placement of a mechanical valve, 51% had placement of a bioprosthetic valve, 9% had aortic valve repair, and 2% had a Ross procedure. In the STS congenital database, among patients 12 to 30 years of age undergoing aortic valve surgery, 21% had placement of a mechanical valve, 18% had placement of a bioprosthetic valve, 30% had aortic valve repair, and 24% had a Ross procedure. In the future, the balance among these options may be altered by design improvements in prosthetic valves, alternatives to warfarin, the development of new patch materials for valve repair, and techniques to avoid Ross autograft failure.

  17. Process and Outcome Study of Multidisciplinary Prosthetic Treatment for Velopharyngeal Dysfunction

    ERIC Educational Resources Information Center

    Sell, Debbie; Mars, Michael; Worrell, Emma

    2006-01-01

    Background: A prosthetic approach to velopharyngeal dysfunction (VPD) is not new. However, a collaborative interdisciplinary team approach by a speech-and-language therapist, dental specialist and maxillofacial technician, including accurate fitting using nasendoscopy, has provided an opportunity to define the clinical care pathway, and audit the…

  18. Locomotor Performance During Rehabilitation of People With Lower Limb Amputation and Prosthetic Nonuse 12 Months After Discharge.

    PubMed

    Roffman, Caroline E; Buchanan, John; Allison, Garry T

    2016-07-01

    It is recognized that multifactorial assessments are needed to evaluate balance and locomotor function in people with lower limb amputation. There is no consensus on whether a single screening tool could be used to identify future issues with locomotion or prosthetic use. The purpose of this study was to determine whether different tests of locomotor performance during rehabilitation were associated with significantly greater risk of prosthetic abandonment at 12 months postdischarge. This was a retrospective cohort study. Data for descriptive variables and locomotor tests (ie, 10-Meter Walk Test [10MWT], Timed "Up & Go" Test [TUGT], Six-Minute Walk Test [6MWT], and Four Square Step Test [FSST]) were abstracted from the medical records of 201 consecutive participants with lower limb amputation. Participants were interviewed and classified as prosthetic users or nonusers at 12 months postdischarge. The Mann-Whitney U test was used to analyze whether there were differences in locomotor performance. Receiver operating characteristic curves were generated to determine performance thresholds, and relative risk (RR) was calculated for nonuse. At 12 months postdischarge, 18% (n=36) of the participants had become prosthetic nonusers. Performance thresholds, area under the curve (AUC), and RR of nonuse (95% confidence intervals [CI]) were: for the 10MWT, if walking speed was ≤0.44 ms(-1) (AUC=0.743), RR of nonuse=2.76 (95% CI=1.83, 3.79; P<.0001); for the TUGT, if time was ≥21.4 seconds (AUC=0.796), RR of nonuse=3.17 (95% CI=2.17, 4.14; P<.0001); for the 6MWT, if distance was ≤191 m (AUC=0.788), RR of nonuse=2.84, (95% CI=2.05, 3.48; P<.0001); and for the FSST, if time was ≥36.6 seconds (AUC=0.762), RR of nonuse=2.76 (95% CI=1.99, 3.39; P<.0001). Missing data, potential recall bias, and assessment times that varied were limitations of the study. Locomotor performance during rehabilitation may predict future risk of prosthetic nonuse. It may be implied that the 10MWT

  19. Optimization of prosthetic foot stiffness to reduce metabolic cost and intact knee loading during below-knee amputee walking: a theoretical study.

    PubMed

    Fey, Nicholas P; Klute, Glenn K; Neptune, Richard R

    2012-11-01

    Unilateral below-knee amputees develop abnormal gait characteristics that include bilateral asymmetries and an elevated metabolic cost relative to non-amputees. In addition, long-term prosthesis use has been linked to an increased prevalence of joint pain and osteoarthritis in the intact leg knee. To improve amputee mobility, prosthetic feet that utilize elastic energy storage and return (ESAR) have been designed, which perform important biomechanical functions such as providing body support and forward propulsion. However, the prescription of appropriate design characteristics (e.g., stiffness) is not well-defined since its influence on foot function and important in vivo biomechanical quantities such as metabolic cost and joint loading remain unclear. The design of feet that improve these quantities could provide considerable advancements in amputee care. Therefore, the purpose of this study was to couple design optimization with dynamic simulations of amputee walking to identify the optimal foot stiffness that minimizes metabolic cost and intact knee joint loading. A musculoskeletal model and distributed stiffness ESAR prosthetic foot model were developed to generate muscle-actuated forward dynamics simulations of amputee walking. Dynamic optimization was used to solve for the optimal muscle excitation patterns and foot stiffness profile that produced simulations that tracked experimental amputee walking data while minimizing metabolic cost and intact leg internal knee contact forces. Muscle and foot function were evaluated by calculating their contributions to the important walking subtasks of body support, forward propulsion and leg swing. The analyses showed that altering a nominal prosthetic foot stiffness distribution by stiffening the toe and mid-foot while making the ankle and heel less stiff improved ESAR foot performance by offloading the intact knee during early to mid-stance of the intact leg and reducing metabolic cost. The optimal design also

  20. Hierarchical and coupling model of factors influencing vessel traffic flow

    PubMed Central

    Liu, Jingxian; Li, Huanhuan; Li, Zongzhi; Tan, Zhirong; Liu, Ryan Wen; Liu, Yi

    2017-01-01

    Understanding the characteristics of vessel traffic flow is crucial in maintaining navigation safety, efficiency, and overall waterway transportation management. Factors influencing vessel traffic flow possess diverse features such as hierarchy, uncertainty, nonlinearity, complexity, and interdependency. To reveal the impact mechanism of the factors influencing vessel traffic flow, a hierarchical model and a coupling model are proposed in this study based on the interpretative structural modeling method. The hierarchical model explains the hierarchies and relationships of the factors using a graph. The coupling model provides a quantitative method that explores interaction effects of factors using a coupling coefficient. The coupling coefficient is obtained by determining the quantitative indicators of the factors and their weights. Thereafter, the data obtained from Port of Tianjin is used to verify the proposed coupling model. The results show that the hierarchical model of the factors influencing vessel traffic flow can explain the level, structure, and interaction effect of the factors; the coupling model is efficient in analyzing factors influencing traffic volumes. The proposed method can be used for analyzing increases in vessel traffic flow in waterway transportation system. PMID:28414747

  1. Quantitative influence of risk factors on blood glucose level.

    PubMed

    Chen, Songjing; Luo, Senlin; Pan, Limin; Zhang, Tiemei; Han, Longfei; Zhao, Haixiu

    2014-01-01

    The aim of this study is to quantitatively analyze the influence of risk factors on the blood glucose level, and to provide theory basis for understanding the characteristics of blood glucose change and confirming the intervention index for type 2 diabetes. The quantitative method is proposed to analyze the influence of risk factors on blood glucose using back propagation (BP) neural network. Ten risk factors are screened first. Then the cohort is divided into nine groups by gender and age. According to the minimum error principle, nine BP models are trained respectively. The quantitative values of the influence of different risk factors on the blood glucose change can be obtained by sensitivity calculation. The experiment results indicate that weight is the leading cause of blood glucose change (0.2449). The second factors are cholesterol, age and triglyceride. The total ratio of these four factors reaches to 77% of the nine screened risk factors. And the sensitivity sequences can provide judgment method for individual intervention. This method can be applied to risk factors quantitative analysis of other diseases and potentially used for clinical practitioners to identify high risk populations for type 2 diabetes as well as other disease.

  2. Progress Toward Optimizing Prosthetic Socket Fit and Suspension Using Elevated Vacuum to Promote Residual Limb Health

    PubMed Central

    Wernke, Matthew M.; Schroeder, Ryan M.; Haynes, Michael L.; Nolt, Lonnie L.; Albury, Alexander W.; Colvin, James M.

    2017-01-01

    Objective: Prosthetic sockets are custom made for each amputee, yet there are no quantitative tools to determine the appropriateness of socket fit. Ensuring a proper socket fit can have significant effects on the health of residual limb soft tissues and overall function and acceptance of the prosthetic limb. Previous work found that elevated vacuum pressure data can detect movement between the residual limb and the prosthetic socket; however, the correlation between the two was specific to each user. The overall objective of this work is to determine the relationship between elevated vacuum pressure deviations and prosthetic socket fit. Approach: A tension compression machine was used to apply repeated controlled forces onto a residual limb model with sockets of different internal volume. Results: The vacuum pressure–displacement relationship was dependent on socket fit. The vacuum pressure data were sensitive enough to detect differences of 1.5% global volume and can likely detect differences even smaller. Limb motion was reduced as surface area of contact between the limb model and socket was maximized. Innovation: The results suggest that elevated vacuum pressure data provide information to quantify socket fit. Conclusions: This study provides evidence that the use of elevated vacuum pressure data may provide a method for prosthetists to quantify and monitor socket fit. Future studies should investigate the relationship between socket fit, limb motion, and limb health to define optimal socket fit parameters. PMID:28736683

  3. Analysis of clinically important factors on the performance of advanced hydraulic, microprocessor-controlled exo-prosthetic knee joints based on 899 trial fittings

    PubMed Central

    Hahn, Andreas; Lang, Michael; Stuckart, Claudia

    2016-01-01

    Abstract The objective of this work is to evaluate whether clinically important factors may predict an individual's capability to utilize the functional benefits provided by an advanced hydraulic, microprocessor-controlled exo-prosthetic knee component. This retrospective cross-sectional cohort analysis investigated the data of above knee amputees captured during routine trial fittings. Prosthetists rated the performance indicators showing the functional benefits of the advanced maneuvering capabilities of the device. Subjects were asked to rate their perception. Simple and multiple linear and logistic regression was applied. Data from 899 subjects with demographics typical for the population were evaluated. Ability to vary gait speed, perform toileting, and ascend stairs were identified as the most sensitive performance predictors. Prior C-Leg users showed benefits during advanced maneuvering. Variables showed plausible and meaningful effects, however, could not claim predictive power. Mobility grade showed the largest effect but also failed to be predictive. Clinical parameters such as etiology, age, mobility grade, and others analyzed here do not suffice to predict individual potential. Daily walking distance may pose a threshold value and be part of a predictive instrument. Decisions based solely on single parameters such as mobility grade rating or walking distance seem to be questionable. PMID:27828871

  4. Factors influencing healthcare service quality

    PubMed Central

    Mosadeghrad, Ali Mohammad

    2014-01-01

    Background: The main purpose of this study was to identify factors that influence healthcare quality in the Iranian context. Methods: Exploratory in-depth individual and focus group interviews were conducted with 222 healthcare stakeholders including healthcare providers, managers, policy-makers, and payers to identify factors affecting the quality of healthcare services provided in Iranian healthcare organisations. Results: Quality in healthcare is a production of cooperation between the patient and the healthcare provider in a supportive environment. Personal factors of the provider and the patient, and factors pertaining to the healthcare organisation, healthcare system, and the broader environment affect healthcare service quality. Healthcare quality can be improved by supportive visionary leadership, proper planning, education and training, availability of resources, effective management of resources, employees and processes, and collaboration and cooperation among providers. Conclusion: This article contributes to healthcare theory and practice by developing a conceptual framework that provides policy-makers and managers a practical understanding of factors that affect healthcare service quality. PMID:25114946

  5. The Selection of Students for Orthotic-Prosthetic Educational Programs. Final Report.

    ERIC Educational Resources Information Center

    Pedersen, E. Eugene; Vash, Carolyn L.

    The study was designed to develop and validate a set of measures that might be useful in predicting "success" in orthotic and prosthetic educational programs. Two hundred and eleven entering students from four institutions were administered the screening battery. The institutions were: Cerritos College, New York University, Northwestern…

  6. Soft Factors Influence College Enrollment

    ERIC Educational Resources Information Center

    Fogg, Neeta P.; Harrington, Paul E.

    2010-01-01

    Evidence about the role that "soft factors" like student engagement and school environment play in influencing whether high school students go on to enroll in college is hard to come by. Over the past two years, the Center for Labor Market Studies (CLMS) of Northeastern University, with support from the Nellie Mae Education Foundation…

  7. Local signaling from a retinal prosthetic in a rodent retinitis pigmentosa model in vivo

    NASA Astrophysics Data System (ADS)

    Fransen, James W.; Pangeni, Gobinda; Pardue, Machelle T.; McCall, Maureen A.

    2014-08-01

    Objective. In clinical trials, retinitis pigmentosa patients implanted with a retinal prosthetic device show enhanced spatial vision, including the ability to read large text and navigate. New prosthetics aim to increase spatial resolution by decreasing pixel/electrode size and limiting current spread. To examine spatial resolution of a new prosthetic design, we characterized and compared two photovoltaic array (PVA) designs and their interaction with the retina after subretinal implantation in transgenic S334ter line 3 rats (Tg S334ter-3). Approach. PVAs were implanted subretinally at two stages of degeneration and assessed in vivo using extracellular recordings in the superior colliculus (SC). Several aspects of this interaction were evaluated by varying duration, irradiance and position of a near infrared laser focused on the PVA. These characteristics included: activation threshold, response linearity, SC signal topography and spatial localization. The major design difference between the two PVA designs is the inclusion of local current returns in the newer design. Main results. When tested in vivo, PVA-evoked response thresholds were independent of pixel/electrode size, but differ between the new and old PVA designs. Response thresholds were independent of implantation age and duration (⩽7.5 months). For both prosthesis designs, threshold intensities were within established safety limits. PVA-evoked responses require inner retina synaptic transmission and do not directly activate retinal ganglion cells. The new PVA design evokes local retinal activation, which is not found with the older PVA design that lacks local current returns. Significance. Our study provides in vivo evidence that prosthetics make functional contacts with the inner nuclear layer at several stages of degeneration. The new PVA design enhances local activation within the retina and SC. Together these results predict that the new design can potentially harness the inherent processing within

  8. Factors influencing US medical students' decision to pursue surgery.

    PubMed

    Schmidt, Lauren E; Cooper, Clairice A; Guo, Weidun Alan

    2016-06-01

    Interest and applications to surgery have steadily decreased over recent years in the United States. The goal of this review is to collect the current literature regarding US medical students' experience in surgery and factors influencing their intention to pursue surgery as a career. We hypothesize that multiple factors influence US medical students' career choice in surgery. Six electronic databases (PubMed, SCOPUS, Web of Science, Education Resources Information Center, Embase, and PsycINFO) were searched. The inclusion criteria were studies published after the new century related to factors influencing surgical career choice among US medical students. Factors influencing US medical student surgical career decision-making were recorded. A quality index score was given to each article selected to minimize risk of bias. We identified 38 relevant articles of more than 1000 nonduplicated titles. The factors influencing medical student decision for a surgical career were categorized into five domains: mentorship and role model (n = 12), experience (clerkship n = 9, stereotype n = 4), timing of exposure (n = 9), personal (lifestyle n = 8, gender n = 6, finance n = 3), and others (n = 2). This comprehensive systemic review identifies mentorship, experience in surgery, stereotypes, timing of exposure, and personal factors to be major determinants in medical students' decisions to pursue surgery. These represent areas that can be improved to attract applicants to general surgery residencies. Surgical faculty and residents can have a positive influence on medical students' decisions to pursue surgery as a career. Early introduction to the field of surgery, as well as recruitment strategies during the preclinical and clinical years of medical school can increase students' interest in a surgical career. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Bio-absorbable antibiotic impregnated beads for the treatment of prosthetic vascular graft infections.

    PubMed

    Genovese, Elizabeth A; Avgerinos, Efthymios D; Baril, Donald T; Makaroun, Michel S; Chaer, Rabih A

    2016-12-01

    There is limited investigation into the use of bio-absorbable antibiotic beads for the treatment of prosthetic vascular graft infections. Our goal was to investigate the rates of infection eradication, graft preservation, and limb salvage in patients who are not candidates for graft explant or extensive reconstruction. A retrospective review of patients implanted with antibiotic impregnated bio-absorbable calcium sulfate beads at a major university center was conducted. Six patients with prosthetic graft infections were treated with bio-absorbable antibiotics beads from 2012-2014. Grafts included an aortobifemoral, an aorto-hepatic/superior mesenteric artery, and four extra-anatomic bypasses. Pathogens included Gram-positive and Gram-negative bacteria. Half of the patients underwent graft explant with reconstruction and half debridement of the original graft, all with antibiotic bead placement around the graft. Mean follow-up was 7.3 ± 8.3 months; all patients had infection resolution, healed wounds, and 100% graft patency, limb salvage, and survival. This report details the successful use of bio-absorbable antibiotic beads for the treatment prosthetic vascular graft infections in patients at high risk for graft explant or major vascular reconstruction. At early follow-up, we demonstrate successful infection suppression, graft preservation, and limb salvage with the use of these beads in a subset of vascular patients. © The Author(s) 2016.

  10. A training platform for many-dimensional prosthetic devices using a virtual reality environment

    PubMed Central

    Putrino, David; Wong, Yan T.; Weiss, Adam; Pesaran, Bijan

    2014-01-01

    Brain machine interfaces (BMIs) have the potential to assist in the rehabilitation of millions of patients worldwide. Despite recent advancements in BMI technology for the restoration of lost motor function, a training environment to restore full control of the anatomical segments of an upper limb extremity has not yet been presented. Here, we develop a virtual upper limb prosthesis with 27 independent dimensions, the anatomical dimensions of the human arm and hand, and deploy the virtual prosthesis as an avatar in a virtual reality environment (VRE) that can be controlled in real-time. The prosthesis avatar accepts kinematic control inputs that can be captured from movements of the arm and hand as well as neural control inputs derived from processed neural signals. We characterize the system performance under kinematic control using a commercially available motion capture system. We also present the performance under kinematic control achieved by two non-human primates (Macaca Mulatta) trained to use the prosthetic avatar to perform reaching and grasping tasks. This is the first virtual prosthetic device that is capable of emulating all the anatomical movements of a healthy upper limb in real-time. Since the system accepts both neural and kinematic inputs for a variety of many-dimensional skeletons, we propose it provides a customizable training platform for the acquisition of many-dimensional neural prosthetic control. PMID:24726625

  11. Cryopreserved Human Allografts for the Reconstruction of Aortic and Peripheral Prosthetic Graft Infection.

    PubMed

    Bossi, Matteo; Tozzi, Matteo; Franchin, Marco; Ferraro, Stefania; Rivolta, Nicola; Ferrario, Massimo; Guttadauro, Chiara; Castelli, Patrizio; Piffaretti, Gabriele

    2017-12-25

    Background : This study aimed to present cases with cryopreserved human allografts (CHAs) for vascular reconstruction in both aortic and peripheral infected prosthetic grafts. Materials and Methods : This is a single center, observational descriptive study with retrospective analysis. In all cases, the infected prosthetic graft material was completely removed. At discharge, patients were administered anticoagulants. Follow-up examinations included clinical visits, echo-color-Doppler ultrasounds, or computed tomography angiography within 30 days and at 3, 6, and 12 months after the treatment, and then twice per year. Results : We treated 21 patients (90% men, n=19) with the mean age of 71±12 years and mean interval between the initial operation and replacement with CHA of 30 months [range, 1-216; interquartile range (IQR), 2-36]. In-hospital mortality was 14% (n=3); no CHA-related complication led to death. Limb salvage was 100%. No patient was lost at the median follow-up of 14 months (range, 2-61; IQR, 6-39). No rupture, aneurysmal degeneration, or re-infection occurred. Estimated freedom from CHA-related adverse events (95% confidence interval, 43-63) was 95% at 3 years. Conclusion : In our experience, CHAs are a viable option for prosthetic graft infections and provide satisfactory clinical results and favorable stability because of a very low rate of CHA-related adverse events during follow-up.

  12. Bio-absorbable antibiotic impregnated beads for the treatment of prosthetic vascular graft infections

    PubMed Central

    Genovese, Elizabeth A; Avgerinos, Efthymios D; Baril, Donald T; Makaroun, Michel S; Chaer, Rabih A

    2017-01-01

    Objective There is limited investigation into the use of bio-absorbable antibiotic beads for the treatment of prosthetic vascular graft infections. Our goal was to investigate the rates of infection eradication, graft preservation, and limb salvage in patients who are not candidates for graft explant or extensive reconstruction. Methods A retrospective review of patients implanted with antibiotic impregnated bio-absorbable calcium sulfate beads at a major university center was conducted. Results Six patients with prosthetic graft infections were treated with bio-absorbable antibiotics beads from 2012–2014. Grafts included an aortobifemoral, an aorto-hepatic/superior mesenteric artery, and four extra-anatomic bypasses. Pathogens included Gram-positive and Gram-negative bacteria. Half of the patients underwent graft explant with reconstruction and half debridement of the original graft, all with antibiotic bead placement around the graft. Mean follow-up was 7.3±8.3 months; all patients had infection resolution, healed wounds, and 100% graft patency, limb salvage, and survival. Conclusion This report details the successful use of bio-absorbable antibiotic beads for the treatment prosthetic vascular graft infections in patients at high risk for graft explant or major vascular reconstruction. At early follow-up, we demonstrate successful infection suppression, graft preservation, and limb salvage with the use of these beads in a subset of vascular patients. PMID:26896286

  13. Candida glabrata prosthetic joint infection, successfully treated with anidulafungin: A case report and review of the literature.

    PubMed

    Koutserimpas, Christos; Samonis, George; Velivassakis, Emmanouil; Iliopoulou-Kosmadaki, Stylliani; Kontakis, Georgios; Kofteridis, Diamantis P

    2018-04-01

    Non-albicans Candida prosthetic joint infection (PJI) is extremely rare. A case of a Candida glabrata knee PJI is a 68-year-old splenectomised female smoker, suffering from chronic obstructive pulmonary disease (COPD) and alcoholism is reported. The patient presented with a peri-prosthetic fracture, 15 years after total knee replacement surgery. Cultures of the intraoperative peri-prosthetic tissue and materials yielded C. glabrata, as well as a methicillin-resistant S. epidermitis. The patient was treated with anidulafungin and vancomycin. The knee prosthetic joint was removed and cement-spacer with vancomycin and gentamycin was placed. Additionally, an external fixation was performed. A second stage revision surgery was planned, after completion of the antimicrobial and antifungal treatment. The patient is followed up for 4 months without signs, symptoms or findings of infection. PJI Candida infections require a high clinical suspicion index. It is of utmost importance to report these cases, since there is no consensus yet of the proper antifungal treatment. Furthermore, a literature review regarding treatment of those cases is provided. First-line treatment with an echinocandin seems most proper, due to their fungicidal properties, their effectiveness against biofilm, as well as their minimal toxicity, making them ideal for long-term use. Further experience is needed, for better understanding the disease's pathogenesis and optimal treatment. © 2017 Blackwell Verlag GmbH.

  14. 78 FR 48941 - Advisory Committee on Prosthetics and Special-Disabilities Programs, Notice of Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-12

    ...- art prosthetics and the associated rehabilitation research, development, and evaluation of such..., blindness or visual impairments, loss of extremities or loss of function, deafness or hearing impairment...

  15. Tooth loss, prosthetic status and treatment needs among industrial workers in Belgaum, Karnataka, India.

    PubMed

    Patil, Vishal V; Shigli, Kamal; Hebbal, Mamata; Agrawal, Neha

    2012-01-01

    The health of industrial workers often goes uncared for due to their stressful working conditions, busy schedules and poor economic conditions. A cross-sectional survey was conducted to determine the prevalence of tooth loss, prosthetic status and treatment needs among industrial workers in Belgaum, Karnataka, India according to the criteria described in the World Health Organization (WHO) Oral Health Assessment form (1997). A total of 614 workers participated in the study. Information was obtained regarding their oral hygiene practice. The presence or absence of habits, and the frequency and duration since the last visit to a dentist were recorded followed by clinical examination. Chi-square test was used to determine the association between the variables and tooth loss. There was a statistically significant difference between the number of missing teeth in different age groups, methods of cleaning, smoking habits and visits to the dentist. Regarding prosthetic status, only one worker had a fixed prosthesis in the mandibular arch. The study revealed that tooth loss was associated with oral hygiene practices, habits and visits to the dentist. Poor prosthetic status and high treatment needs were observed. This study emphasized the need for improved dental health awareness and availability of dental facilities to industrial workers.

  16. Energy expenditure and activity of transfemoral amputees using mechanical and microprocessor-controlled prosthetic knees.

    PubMed

    Kaufman, Kenton R; Levine, James A; Brey, Robert H; McCrady, Shelly K; Padgett, Denny J; Joyner, Michael J

    2008-07-01

    To quantify the energy efficiency of locomotion and free-living physical activity energy expenditure of transfemoral amputees using a mechanical and microprocessor-controlled prosthetic knee. Repeated-measures design to evaluate comparative functional outcomes. Exercise physiology laboratory and community free-living environment. Subjects (N=15; 12 men, 3 women; age, 42+/-9 y; range, 26-57 y) with transfemoral amputation. Research participants were long-term users of a mechanical prosthesis (20+/-10 y as an amputee; range, 3-36 y). They were fitted with a microprocessor-controlled knee prosthesis and allowed to acclimate (mean time, 18+/-8 wk) before being retested. Objective measurements of energy efficiency and total daily energy expenditure were obtained. The Prosthetic Evaluation Questionnaire was used to gather subjective feedback from the participants. Subjects demonstrated significantly increased physical activity-related energy expenditure levels in the participant's free-living environment (P=.04) after wearing the microprocessor-controlled prosthetic knee joint. There was no significant difference in the energy efficiency of walking (P=.34). When using the microprocessor-controlled knee, the subjects expressed increased satisfaction in their daily lives (P=.02). People ambulating with a microprocessor-controlled knee significantly increased their physical activity during daily life, outside the laboratory setting, and expressed an increased quality of life.

  17. Evaluation of function, performance, and preference as transfemoral amputees transition from mechanical to microprocessor control of the prosthetic knee.

    PubMed

    Hafner, Brian J; Willingham, Laura L; Buell, Noelle C; Allyn, Katheryn J; Smith, Douglas G

    2007-02-01

    To evaluate differences in function, performance, and preference between mechanical and microprocessor prosthetic knee control technologies. A-B-A-B reversal design. Home, community, and laboratory environments. Twenty-one unilateral, transfemoral amputees. Mechanical control prosthetic knee versus microprocessor control prosthetic knee (Otto Bock C-Leg). Stair rating, hill rating and time, obstacle course time, divided attention task accuracy and time, Amputee Mobility Predictor score, step activity, Prosthesis Evaluation Questionnaire score, Medical Outcomes Study 36-Item Short-Form Health Survey score, self-reported frequency of stumbles and falls, and self-reported concentration required for ambulation. Stair descent score, hill descent time, and hill sound-side step length showed significant (P<.01) improvement with the C-Leg. Users reported a significant (P<.05) decrease in frequency of stumbles and falls, frustration with falling, and difficulty in multitasking while using the microprocessor knee. Subject satisfaction with the C-Leg was significantly (P<.001) greater than the mechanical control prosthesis. The study population showed improved performance when negotiating stairs and hills, reduced frequency of stumbling and falling, and a preference for the microprocessor control C-Leg as compared with the mechanical control prosthetic knee.

  18. Persistent immune thrombocytopenia heralds the diagnosis of Mycobacterium chimaera prosthetic valve endocarditis.

    PubMed

    Sacco, Keith A; Burton, M Caroline

    2017-01-01

    A 63 year old female was admitted for investigation of worsening renal insufficiency. During hospitalization she developed persistent immune thrombocytopenia refractory to supportive or immunosuppressive treatment. She was diagnosed with Mycobacterium chimaera prosthetic valve endocarditis and thrombocytopenia resolved with anti-mycobacterial therapy.

  19. Committing to Memory: Memory Prosthetics Show Promise in Helping Those with Neurodegenerative Disorders.

    PubMed

    Solis, Michele

    2017-01-01

    Cell phone chimes, sticky notes, even the proverbial string around a finger-these timehonored external cues help guard against our inevitable memory lapses. But some internal help to the brain itself may be on the way in the form of what's being called memory prosthetics. Once considered to be on the fringes of neuroscience, the idea of adding hardware to the brain to help with memory has gathered steam. In 2014, the U.S. Defense Advanced Research Projects Agency (DARPA) made a US$30 million investment in memory prosthetic research as part of the Obama administration's Brain Research through Advancing Innovative Neurotechnologies initiative. In August 2016, Kernel, a startup based in Los Angeles, California, announced its goal to develop a clinical memory device for those debilitated by neurodegenerative disorders such as Alzheimer's disease.

  20. Factors that influence the childbearing intentions of Canadian men.

    PubMed

    Roberts, E; Metcalfe, A; Jack, M; Tough, S C

    2011-05-01

    The role of men in the childbearing decision process and the factors that influence men's childbearing intentions have been relatively unexplored in the literature. This study aimed to describe the factors that strongly influence the childbearing intentions of men and to describe differences in these factors according to men's age group. A telephone survey (response rate 84%) was conducted with 495 men between the ages of 20 and 45 living in an urban setting who, at the time of contact, did not have biological children. Men were asked about what factors strongly influence their intention to have children. Univariable and multivariable logistic regressions were conducted to determine if these factors were significantly associated with age. Of those sampled, 86% of men reported that at some point in the future they planned to become a parent. The factors that men considered to be most influential in their childbearing intentions were: the need to be financially secure, their partner's interest/desire to have children, their partner's suitability to be a parent and their personal interest/desire to have children. Men who were 35-45 years old had lower odds of stating that financial security (crude OR: 0.32, 95% CI: 0.18-0.54) and partner's interest in having children (crude OR: 0.57, 95% CI: 0.33-0.99) were very influential, but had higher odds of stating that their biological clock (crude OR: 4.37, 95% CI: 1.78-10.76) was very influential in their childbearing intentions than men in the 20-24 year age group. The factors that influence men's intentions about when to become a parent may change with age. Understanding what influences men to have children, and what they understand about reproductive health is important for education, program and policy development.

  1. 75 FR 65060 - Advisory Committee on Prosthetics and Special-Disabilities Programs; Notice of Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-21

    ...-of-the- art prosthetics and the associated rehabilitation research, development, and evaluation of... injuries, blindness or visual impairments, loss of extremities or loss of function, deafness or hearing...

  2. Factors influencing alcohol safety action project police officers' DWI arrests

    DOT National Transportation Integrated Search

    1974-04-29

    This report summarizes the results of a study to determine the factors influencing ASAP police officers' DWI arrests and the formulation of approaches to minimize the influence of those factors which might tend to constrain the arrest of persons who ...

  3. Marketing Factors Influencing the Overall Satisfaction of Marriage Education Participants.

    ERIC Educational Resources Information Center

    Morris, Michael Lane; Cooper, Catherine; Gross, Kevin H.

    1999-01-01

    Seventy-one married couples attending marriage education workshops were surveyed regarding price, product, place, people, and promotional marketing factors influencing their overall satisfaction as workshop participants. Findings suggest both similar and unique marketing factors influenced husbands' and wives' satisfaction. Recommendations for…

  4. High submuscular placement of urologic prosthetic balloons and reservoirs via transscrotal approach.

    PubMed

    Morey, Allen F; Cefalu, Christopher A; Hudak, Steven J

    2013-02-01

    Traditional placement of inflatable penile prosthesis (IPP) reservoirs and/or artificial urinary sphincter (AUS) balloons into the space of Retzius may be challenging following major pelvic surgery. The aim of this study is to report our 1-year experience using a novel technique for high balloon/reservoir placement beneath the rectus abdominus muscle, thus completely obviating deep pelvic dissection during prosthetic urologic surgery. A retrospective review of all patients who underwent IPP and/or AUS placement between June 2011 and June 2012 was performed. All had AUS balloons and/or IPP reservoirs placed in a submuscular location by bluntly tunneling through the external inguinal ring into a potential space between the transversalis fascia and the rectus abdominus muscle using a long, angled, lung grasping clamp. Patient demographics, perioperative outcomes, and initial follow-up patient-reported outcomes were reviewed. During the study period, 120 submuscular balloons/reservoirs were inserted in 107 consecutive patients who underwent placement of an IPP (61 patients), AUS (33 patients), or both (13 patients). Among our 48 most recent patients, 41 (85%) reported they were totally unable to feel their balloon/reservoir, and all but two patients reported no bother from the submuscular balloon/reservoir placement. Of the 120 total submuscular balloons and reservoirs, surgical time and outcomes of the prosthetic procedures appeared similar to those placed using traditional methods; two reservoirs required revision surgery for repositioning. High submuscular placement of genitourinary prosthetic balloons and reservoirs via a transscrotal approach is both safely and effective, while avoiding deep retropubic dissection. © 2012 International Society for Sexual Medicine.

  5. Prosthetic Tricuspid Valve Thrombosis: Three Case Reports and Literature Review

    PubMed Central

    Yaminisharif, Ahmad; Alemzadeh-Ansari, Mohammad Javad; Ahmadi, Seyed Hossein

    2012-01-01

    A common complication of prosthetic heart valves is thrombosis. Although the incidence of prosthetic valve thrombosis (PVT) in the tricuspid position is high, there are not enough data on the management of it, in contrast to left-sided PVT. Here, we describe three cases of tricuspid PVT with three different management approaches: thrombolytic therapy; close observation with oral anticoagulants; and surgery. The first case was a woman who suffered from recurrent PVT, for which we successfully used Tenecteplase for second and third episodes. We employed Tenecteplase in this case for the first time in the therapy of tricuspid PVT. The second case had fixed leaflets in open position while being symptomless. At six months' follow-up, with the patient having taken oral anticoagulants, the motion of the leaflets was restricted and she was symptomfree. The last case was a woman who had a large thrombus in the right atrium immediately after mitral and tricuspid valvular replacement. The patient underwent re-replacement surgery and a new biological valve was implanted in the tricuspid position. Also, we review the literature on the pathology, signs and symptoms, diagnosis, and management of tricuspid PVT. PMID:23323074

  6. Spark erosion implant prosthetics in the management of an acquired maxillofacial defect.

    PubMed

    Bloem, T J; Baxter, W D; Vivas, J

    1996-03-01

    The concept and use of spark erosion (EDM) prosthetics in implant prosthodontics has been described and demonstrated in its application to a patient suffering maxillofacial trauma. The advantages and disadvantages of this technology have been discussed for the edification of the restorative and surgical provider.

  7. [The incidence and prevalence of complications after urogynaecological and reconstructive pelvic floor prosthetic surgery and management of these complications in women].

    PubMed

    Martan, A; Svabík, K; Masata, J

    2007-12-01

    The aim of this article is to review the incidence and prevalence of complications after prosthetic surgery for POP (pelvic organ prolaps) and USI (urodynamic stress incontinence) and to introduce diagnostic and therapeutic advice into clinical practice. Review article. Gynecological and Obstetric Clinic, 1st LF UK and VFN, Prague. Summary of complications, recent findings, opinions and specific diagnostic and therapeutic recommendations with special focus to vaginal erosion, post-operative voiding difficulties, persisting leakage of urine and de novo urgency. In the last decade the surgical treatment of female USI by prosthetic slings procedures has been shown to be effective with high cure rate and low morbidity. Similary, prosthetic reconstruction of pelvic organ prolapse through the different compartments has been introduced into clinical practice with good anatomical and promising functional results. The article is structured to the different sections, describing the epidemiology and management of complications after prosthetic slings procedures and after vaginal prosthetic treatment of pelvic organ prolapse. The effect of various operations of pelvic floor and USI using synthetic implants may differ, depending on the material of the implant used. Current recommendation for the implants material: a light-weight, flexible polypropylene; Amid's classification: type 1, i.e macro-porous, monofilament material. The advantage of surgical treatment of pelvic floor defect using implants comprises a low percentage of recurrence of the descensus.

  8. Factors influencing arrests for alcohol-related traffic violations

    DOT National Transportation Integrated Search

    1974-09-01

    This report describes factors that were found to influence police officers' arrests of persons suspected of alcohol-related (A/R) traffic violations, and presents recommendations for treating these factors so that a higher level of enforcement might ...

  9. 75 FR 24775 - Advisory Committee on Prosthetics and Special Disabilities Programs; Notice of Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-05

    ... state-of-the- art prosthetics and the associated rehabilitation research, development, and evaluation of..., blindness or visual impairment, loss of extremities or loss of function, deafness or hearing impairment, and...

  10. Characterisation of the responsive properties of two running-specific prosthetic models.

    PubMed

    Grobler, Lara; Ferreira, Suzanne; Vanwanseele, Benedicte; Terblanche, Elmarie E

    2017-04-01

    The need for information regarding running-specific prosthetic properties has previously been voiced. Such information is necessary to assist in athletes' prostheses selection. This study aimed to describe the characteristics of two commercially available running-specific prostheses. The running-specific prostheses were tested (in an experimental setup) without the external interference of athlete performance variations. Four stiffness categories of each running-specific prosthetic model (Xtend ™ and Xtreme ™ ) were tested at seven alignment setups and three drop masses (28, 38 and 48 kg). Results for peak ground reaction force (GRF peak ), contact time ( t c ), flight time ( t f ), reactive strength index (RSI) and maximal compression (Δ L) were determined during controlled dropping of running-specific prostheses onto a force platform with different masses attached to the experimental setup. No statistically significant differences were found between the different setups of the running-specific prostheses. Statistically significant differences were found between the two models for all outcome variables (GRF peak , Xtend > Xtreme; t c , Xtreme > Xtend; t f , Xtreme > Xtend; RSI, Xtend > Xtreme; Δ L, Xtreme > Xtend; p < 0.05). These findings suggest that the Xtreme stores more elastic energy than the Xtend, leading to a greater performance response. The specific responsive features of blades could guide sprint athletes in their choice of running-specific prostheses. Clinical relevance Insights into the running-specific prosthesis (RSP) properties and an understanding of its responsive characteristics have implications for athletes' prosthetic choice. Physiologically and metabolically, a short sprint event (i.e. 100 m) places different demands on the athlete than a long sprint event (i.e. 400 m), and the RSP should match these performance demands.

  11. Simultaneous laparoscopic prosthetic mesh inguinal herniorrhaphy during transperitoneal laparoscopic radical prostatectomy.

    PubMed

    Allaf, Mohamad E; Hsu, Thomas H; Sullivan, Wendy; Su, Li-Ming

    2003-12-01

    Concurrent repair of inguinal hernias during open radical retropubic prostatectomy is well described and commonly practiced. With the advent of the laparoscopic approach to radical prostatectomy, the possibility of concurrent laparoscopic hernia repair merits investigation. We present a case of simultaneous prosthetic mesh onlay hernia repair for bilateral inguinal hernias during laparoscopic transperitoneal radical prostatectomy.

  12. Prosthetic rehabilitation of oral submucous fibrosis patients: A systematic review of published case reports and case series

    PubMed Central

    Patil, Shankargouda; Sarode, Gargi S.; Bhandi, Shilpa; Awan, Kamran Habib; Ferrari, Marco

    2017-01-01

    Background Oral submucous fibrosis (OSF) is an insidious chronic condition characterized by restricted mouth opening. Prosthetic rehabilitation is challenging for OSF patients as obtaining a good impression requires adequate mouth opening. The aim of the present review is to systematically present the data from case reports published in the English-language literature. Method A comprehensive search of the literature databases (PubMed, Medline, SCOPUS, Web of Science and Google Scholar) along with the references of published articles on prosthetic rehabilitation in OSF patients published to date was conducted. Keywords included a combination of ‘Oral submucous fibrosis’, ‘prosthesis’, ‘dentures’ and/or ‘restricted mouth opening’. Citations from selected references and bibliographic linkages taken from similar cases were included in this review. The inclusion criteria selected for case reports on prosthetic rehabilitation in OSF patients, and cases of restricted mouth opening due to causes other than OSF were excluded from the study. Results A total of 21 cases were identified and analysed from 17 papers published in the English-language literature. Of these, 9 cases employed the sectional denture technique, 4 cases emphasized the need-based treatment approach in which conventional methods were modified, and 4 cases used mouth exercising devices. Finally, 1 case each involved, flexible denture, oral screen prosthesis, oral stents, surgery in conjunction with dentures. Conclusion Prosthetic rehabilitation in OSF patients is a multifaceted approach and should be patient specific, although sectional dentures have achieved the best results. PMID:28877246

  13. Prosthetic rehabilitation of oral submucous fibrosis patients: A systematic review of published case reports and case series.

    PubMed

    Patil, Shankargouda; Sarode, Sachin Chakradhar; Sarode, Gargi S; Bhandi, Shilpa; Awan, Kamran Habib; Ferrari, Marco

    2017-01-01

    Oral submucous fibrosis (OSF) is an insidious chronic condition characterized by restricted mouth opening. Prosthetic rehabilitation is challenging for OSF patients as obtaining a good impression requires adequate mouth opening. The aim of the present review is to systematically present the data from case reports published in the English-language literature. A comprehensive search of the literature databases (PubMed, Medline, SCOPUS, Web of Science and Google Scholar) along with the references of published articles on prosthetic rehabilitation in OSF patients published to date was conducted. Keywords included a combination of 'Oral submucous fibrosis', 'prosthesis', 'dentures' and/or 'restricted mouth opening'. Citations from selected references and bibliographic linkages taken from similar cases were included in this review. The inclusion criteria selected for case reports on prosthetic rehabilitation in OSF patients, and cases of restricted mouth opening due to causes other than OSF were excluded from the study. A total of 21 cases were identified and analysed from 17 papers published in the English-language literature. Of these, 9 cases employed the sectional denture technique, 4 cases emphasized the need-based treatment approach in which conventional methods were modified, and 4 cases used mouth exercising devices. Finally, 1 case each involved, flexible denture, oral screen prosthesis, oral stents, surgery in conjunction with dentures. Prosthetic rehabilitation in OSF patients is a multifaceted approach and should be patient specific, although sectional dentures have achieved the best results.

  14. Identification of critical zones in the flow through prosthetic heart valves

    NASA Astrophysics Data System (ADS)

    Lopez, A.; Ledesma, R.; Zenit, R.; Pulos, G.

    2008-11-01

    The hemodynamic properties of prosthetic heart valves can cause blood damage and platelet activation due to the non- physiological flow patterns. Blood recirculation and elevated shear stresses are believed to be responsible for these complications. The objective of this study is to identify and quantify the conditions for which recirculation and high stress zones appear. We have performed a comparative study between a mechanical monoleaflet and biological valve. In order to generate the flow conditions to test the prosthesis, we have built a hydraulic circuit which reproduces the human systemic circulation, on the basis of the Windkessel model. This model is based on an electrical analogy which consists of an arterial resistance and compliance. Using PIV 3D- Stereo measurements, taken downstream from the prosthetic heart valves, we have reconstructed the full phase-averaged tridimensional velocity field. Preliminary results show that critical zones are more prominent in mechanical prosthesis, indicating that valves made with bio-materials are less likely to produce blood trauma. This is in accordance with what is generally found in the literature.

  15. Prosthetic EMG control enhancement through the application of man-machine principles

    NASA Technical Reports Server (NTRS)

    Simcox, W. A.

    1977-01-01

    An area in medicine that appears suitable to man-machine principles is rehabilitation research, particularly when the motor aspects of the body are involved. If one considers the limb, whether functional or not, as the machine, the brain as the controller and the neuromuscular system as the man-machine interface, the human body is reduced to a man-machine system that can benefit from the principles behind such systems. The area of rehabilitation that this paper deals with is that of an arm amputee and his prosthetic device. Reducing this area to its man-machine basics, the problem becomes one of attaining natural multiaxis prosthetic control using Electromyographic activity (EMG) as the means of communication between man and prothesis. In order to use EMG as the communication channel it must be amplified and processed to yield a high information signal suitable for control. The most common processing scheme employed is termed Mean Value Processing. This technique for extracting the useful EMG signal consists of a differential to single ended conversion to the surface activity followed by a rectification and smoothing.

  16. Comparative biomechanical analysis of current microprocessor-controlled prosthetic knee joints.

    PubMed

    Bellmann, Malte; Schmalz, Thomas; Blumentritt, Siegmar

    2010-04-01

    To investigate and identify functional differences of 4 microprocessor-controlled prosthetic knee joints (C-Leg, Hybrid Knee [also called Energy Knee], Rheo Knee, Adaptive 2). Tested situations were walking on level ground, on stairs and ramps; additionally, the fall prevention potentials for each design were examined. The measuring technology used included an optoelectronic camera system combined with 2 forceplates as well as a mobile spiroergometric system. The study was conducted in a gait laboratory. Subjects with unilateral transfemoral amputations (N=9; mobility grade, 3-4; age, 22-49y) were tested. Participants were fitted and tested with 4 different microprocessor-controlled knee joints. Static prosthetic alignment, time distance parameters, kinematic and kinetic data and metabolic energy consumption. Compared with the Hybrid Knee and the Adaptive 2, the C-Leg offers clear advantages in the provision of adequate swing phase flexion resistances and terminal extension damping during level walking at various speeds, especially at higher walking speeds. The Rheo Knee provides sufficient terminal extension; however, swing phase flexion resistances seem to be too low. The values for metabolic energy consumption show only slight differences during level walking. The joint resistances generated for descending stairs and ramps relieve the contralateral side to varying degrees. When walking on stairs, safety-relevant technical differences between the investigated joint types can be observed. Designs with adequate internal resistances offer stability advantages when the foot is positioned on the step. Stumble recovery tests reveal that the different knee joint designs vary in their effectiveness in preventing the patient from falling. The patient benefits provided by the investigated electronic prosthetic knee joints differ considerably. The C-Leg appears to offer the amputee greater functional and safety-related advantages than the other tested knee joints. Reduced

  17. 77 FR 65609 - Advisory Committee on Prosthetics and Special-Disabilities Programs; Notice of Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-29

    ... the Secretary of Veterans Affairs on VA's prosthetics programs designed to provide state-of-the- art... program administered by the Secretary to serve Veterans with spinal cord injuries, blindness or visual...

  18. 78 FR 69176 - Advisory Committee on Prosthetics and Special-Disabilities Programs; Notice of Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-18

    ... the Secretary of Veterans Affairs on VA's prosthetics programs designed to provide state-of-the- art... program administered by the Secretary to serve Veterans with spinal cord injuries, blindness or visual...

  19. 76 FR 21107 - Advisory Committee on Prosthetics and Special-Disabilities Programs; Notice of Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-14

    ... the Secretary of Veterans Affairs on VA's prosthetics programs designed to provide state-of-the art... program administered by the Secretary to serve Veterans with spinal cord injuries, blindness or visual...

  20. Program Evaluation of Outcomes Based Orthotic and Prosthetic Education

    DTIC Science & Technology

    2007-12-01

    writing of new Biomechanics and Gait curricula and syllabi; implementation of online learning strategies through the use of Blackboard online learning...TERMS Prosthetics, Orthotics, Prosthesis , Orthosis, Amputation, Outcomes Based Evaluation 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF...Appendix III. Appendix IV. Sample Syllabus – Biomechanics …………………………… 24 Appendix V. Sample Final Examination……………………………………. 29

  1. Factors influencing health information system adoption in American hospitals.

    PubMed

    Wang, Bill B; Wan, Thomas T H; Burke, Darrell E; Bazzoli, Gloria J; Lin, Blossom Y J

    2005-01-01

    To study the number of health information systems (HISs), applicable to administrative, clinical, and executive decision support functionalities, adopted by acute care hospitals and to examine how hospital market, organizational, and financial factors influence HIS adoption. A cross-sectional analysis was performed with 1441 hospitals selected from metropolitan statistical areas in the United States. Multiple data sources were merged. Six hypotheses were empirically tested by multiple regression analysis. HIS adoption was influenced by the hospital market, organizational, and financial factors. Larger, system-affiliated, and for-profit hospitals with more preferred provider organization contracts are more likely to adopt managerial information systems than their counterparts. Operating revenue is positively associated with HIS adoption. The study concludes that hospital organizational and financial factors influence on hospitals' strategic adoption of clinical, administrative, and managerial information systems.

  2. Maturity of hospital information systems: Most important influencing factors.

    PubMed

    Vidal Carvalho, João; Rocha, Álvaro; Abreu, António

    2017-07-01

    Maturity models facilitate organizational management, including information systems management, with hospital organizations no exception. This article puts forth a study carried out with a group of experts in the field of hospital information systems management with a view to identifying the main influencing factors to be included in an encompassing maturity model for hospital information systems management. This study is based on the results of a literature review, which identified maturity models in the health field and relevant influencing factors. The development of this model is justified to the extent that the available maturity models for the hospital information systems management field reveal multiple limitations, including lack of detail, absence of tools to determine their maturity and lack of characterization for stages of maturity structured by different influencing factors.

  3. A Review of Factors Influencing Athletes' Food Choices.

    PubMed

    Birkenhead, Karen L; Slater, Gary

    2015-11-01

    Athletes make food choices on a daily basis that can affect both health and performance. A well planned nutrition strategy that includes the careful timing and selection of appropriate foods and fluids helps to maximize training adaptations and, thus, should be an integral part of the athlete's training programme. Factors that motivate food selection include taste, convenience, nutrition knowledge and beliefs. Food choice is also influenced by physiological, social, psychological and economic factors and varies both within and between individuals and populations. This review highlights the multidimensional nature of food choice and the depth of previous research investigating eating behaviours. Despite numerous studies with general populations, little exploration has been carried out with athletes, yet the energy demands of sport typically require individuals to make more frequent and/or appropriate food choices. While factors that are important to general populations also apply to athletes, it seems likely, given the competitive demands of sport, that performance would be an important factor influencing food choice. It is unclear if athletes place the same degree of importance on these factors or how food choice is influenced by involvement in sport. There is a clear need for further research exploring the food choice motives of athletes, preferably in conjunction with research investigating dietary intake to establish if intent translates into practice.

  4. A photogrammetry-based system for 3D surface reconstruction of prosthetics and orthotics.

    PubMed

    Li, Guang-kun; Gao, Fan; Wang, Zhi-gang

    2011-01-01

    The objective of this study is to develop an innovative close range digital photogrammetry (CRDP) system using the commercial digital SLR cameras to measure and reconstruct the 3D surface of prosthetics and orthotics. This paper describes the instrumentation, techniques and preliminary results of the proposed system. The technique works by taking pictures of the object from multiple view angles. The series of pictures were post-processed via feature point extraction, point match and 3D surface reconstruction. In comparison with the traditional method such as laser scanning, the major advantages of our instrument include the lower cost, compact and easy-to-use hardware, satisfactory measurement accuracy, and significantly less measurement time. Besides its potential applications in prosthetics and orthotics surface measurement, the simple setup and its ease of use will make it suitable for various 3D surface reconstructions.

  5. Expert training with standardized operative technique helps establish a successful penile prosthetics program for urologic resident education.

    PubMed

    King, Ashley B; Klausner, Adam P; Johnson, Corey M; Moore, Blake W; Wilson, Steven K; Grob, B Mayer

    2011-10-01

    The challenge of resident education in urologic surgery programs is to overcome disparity imparted by diverse patient populations, limited training times, and inequalities in the availability of expert surgical educators. Specifically, in the area of prosthetic urology, only a small proportion of programs have full-time faculty available to train residents in this discipline. To examine whether a new model using yearly training sessions from a recognized expert can establish a successful penile prosthetics program and result in better outcomes, higher case volumes, and willingness to perform more complex surgeries. A recognized expert conducted one to two operative training sessions yearly to teach standardized technique for penile prosthetics to residents. Each session consisted of three to four operative cases performed under the direct supervision of the expert. Retrospective data were collected from all penile prosthetic operations before (February, 2000 to June, 2004: N = 44) and after (July, 2004 to October, 2007: N = 79) implementation of these sessions. Outcomes reviewed included patient age, race, medical comorbidities, operative time, estimated blood loss, type of prosthesis, operative approach, drain usage, length of stay, and complications including revision/explantation rates. Statistical analysis was performed using Student's t-tests, Fisher's tests, and survival curves using the Kaplan-Meier technique (P value ≤ 0.05 to define statistical significance). Patient characteristics were not significantly different pre- vs. post-training. Operative time and estimated blood loss significantly decreased. Inflatable implants increased from 19/44 (43.2%, pre-training) to 69/79 (87.3%, post-training) (P < 0.01). Operations per year increased from 9.96 (pre-training) to 24 (post-training) (P < 0.01). Revision/explantation occurred in 11/44 patients (25%, pre-training) vs. 7/79 (8.9%, post-training) (P < 0.05). These data demonstrate that yearly sessions with a

  6. Factors Influencing Teaching Choice in Turkey

    ERIC Educational Resources Information Center

    Kilinc, Ahmet; Watt, Helen M. G.; Richardson, Paul W.

    2012-01-01

    Why choose to become a teacher in Turkey? The authors examined motivations and perceptions among preservice teachers (N = 1577) encompassing early childhood, primary and secondary education. The Factors Influencing Teaching Choice (FIT-Choice) instrument was translated into Turkish and its construct validity and reliability assessed. Altruistic…

  7. Analysis and Evaluation of the Dynamic Performance of SMA Actuators for Prosthetic Hand Design

    NASA Astrophysics Data System (ADS)

    O'Toole, Kevin T.; McGrath, Mark M.; Coyle, Eugene

    2009-08-01

    It is widely acknowledged within the biomedical engineering community that shape memory alloys (SMAs) exhibit great potential for application in the actuation of upper limb prosthesis designs. These lightweight actuators are particularly suitable for prosthetic hand solutions. A four-fingered, 12 degree-of-freedom prosthetic hand has been developed featuring SMA bundle actuators embedded within the palmar structure. Joule heating of the SMA bundle actuators generates sufficient torque at the fingers to allow a wide range of everyday tasks to be carried out. Transient characterization of SMA bundles has shown that performance/response during heating and cooling differs substantially. Natural convection is insufficient to provide for adequate cooling during elongation of the actuators. An experimental test-bed has been developed to facilitate analysis of the heat transfer characteristics of the appropriately sized SMA bundle actuators for use within the prosthetic hand design. Various modes of heat sinking are evaluated so that the most effective wire-cooling solution can be ascertained. SMA bundles of varying size will be used so that a generalized model of the SMA displacement performance under natural and forced cooling conditions can be obtained. The optimum cooling solution will be implemented onto the mechanical hand framework in future work. These results, coupled with phenomenological models of SMA behavior, will be used in the development of an effective control strategy for this application in future work.

  8. Energy Expenditure and Activity of Transfemoral Amputees Using Mechanical and Microprocessor-Controlled Prosthetic Knees

    PubMed Central

    Kaufman, Kenton R.; Levine, James A.; Brey, Robert H.; McCrady, Shelly K.; Padgett, Denny J.; Joyner, Michael J.

    2009-01-01

    Objective To quantify the energy efficiency of locomotion and free-living physical activity energy expenditure of transfemoral amputees using a mechanical and microprocessor-controlled prosthetic knee. Design Repeated-measures design to evaluate comparative functional outcomes. Setting Exercise physiology laboratory and community free-living environment. Participants Subjects (N=15; 12 men, 3 women; age, 42±9y; range, 26 –57y) with transfemoral amputation. Intervention Research participants were long-term users of a mechanical prosthesis (20±10y as an amputee; range, 3–36y). They were fitted with a microprocessor-controlled knee prosthesis and allowed to acclimate (mean time, 18±8wk) before being retested. Main Outcome Measures Objective measurements of energy efficiency and total daily energy expenditure were obtained. The Prosthetic Evaluation Questionnaire was used to gather subjective feedback from the participants. Results Subjects demonstrated significantly increased physical activity–related energy expenditure levels in the participant’s free-living environment (P=.04) after wearing the microprocessor-controlled prosthetic knee joint. There was no significant difference in the energy efficiency of walking (P=.34). When using the microprocessor-controlled knee, the subjects expressed increased satisfaction in their daily lives (P=.02). Conclusions People ambulating with a microprocessor-controlled knee significantly increased their physical activity during daily life, outside the laboratory setting, and expressed an increased quality of life. PMID:18586142

  9. Factors Influencing Part-time Faculty Engagement With Online Nursing Programs.

    PubMed

    Reneau, Margaret; Wallace, Cara; Claywell, Lora; Price, Jill; Burdi, Melissa; Trybulski, Joanne

    2018-03-28

    This research investigated factors that influenced the engagement of part-time faculty teaching in online nursing programs with their institutions. Of the 257 part-time faculty surveyed, the most significant factor was being supported in decisions regarding student issues, followed by institutional commitment to quality online education. Compensation was moderately influential; a negative factor was requiring too frequent meetings. Understanding factors that influence the engagement of part-time faculty teaching in online nursing programs can help leaders of online programs attract and retain experienced, highly skilled faculty.

  10. The Effect of a Microprocessor Prosthetic Foot on Function and Quality of Life in Transtibial Amputees Who Are Limited Community Ambulators

    DTIC Science & Technology

    2017-09-01

    parallel, randomized, controlled clinical trial designed to determine if a microprocessor controlled prosthetic foot (MPF), with greater range of...clinical trial designed to determine if a microprocessor controlled prosthetic foot (MPF), with greater range of motion and active power, will...Department of the Army position, policy or decision unless so designated by other documentation. CONTRACTING ORGANIZATION: University of Tennessee

  11. Factors That Influence the Practice of Elective Induction of Labor

    PubMed Central

    Moore, Jennifer; Low, Lisa Kane

    2012-01-01

    Elective induction of labor has been linked to increased rates of prematurity and rising rates of cesarean birth. The purpose of this investigation was to evaluate current trends in induction of labor scholarship focusing on evidence-based factors that influence the practice of elective induction. A key word search was conducted to identify studies on the practice of elective induction of labor. Analysis of the findings included clustering and identification of recurrent themes among the articles with 3 categories being identified. Under each category, the words/phrases were further clustered until a construct could be named. A total of 49 articles met inclusion criteria: 7 patient, 6 maternity care provider, and 4 organization factors emerged. Only 4 of the articles identified were evidence based. Patient factors were divided into preferences/convenience, communication, fear, pressure/influence, trust, external influences, and technology. Provider factors were then divided into practice preferences/convenience, lack of information, financial incentives, fear, patient desire/demand, and technology. Organization factors were divided into lack of enforcement/accountability, hospital culture, scheduling of staff, and market share issues. Currently, there is limited data-based information focused on factors that influence elective induction of labor. Despite patient and provider convenience/preferences being cited in the literature, the evidence does not support this practice. PMID:22843006

  12. Improved prosthetic hand control with concurrent use of myoelectric and inertial measurements.

    PubMed

    Krasoulis, Agamemnon; Kyranou, Iris; Erden, Mustapha Suphi; Nazarpour, Kianoush; Vijayakumar, Sethu

    2017-07-11

    Myoelectric pattern recognition systems can decode movement intention to drive upper-limb prostheses. Despite recent advances in academic research, the commercial adoption of such systems remains low. This limitation is mainly due to the lack of classification robustness and a simultaneous requirement for a large number of electromyogram (EMG) electrodes. We propose to address these two issues by using a multi-modal approach which combines surface electromyography (sEMG) with inertial measurements (IMs) and an appropriate training data collection paradigm. We demonstrate that this can significantly improve classification performance as compared to conventional techniques exclusively based on sEMG signals. We collected and analyzed a large dataset comprising recordings with 20 able-bodied and two amputee participants executing 40 movements. Additionally, we conducted a novel real-time prosthetic hand control experiment with 11 able-bodied subjects and an amputee by using a state-of-the-art commercial prosthetic hand. A systematic performance comparison was carried out to investigate the potential benefit of incorporating IMs in prosthetic hand control. The inclusion of IM data improved performance significantly, by increasing classification accuracy (CA) in the offline analysis and improving completion rates (CRs) in the real-time experiment. Our findings were consistent across able-bodied and amputee subjects. Integrating the sEMG electrodes and IM sensors within a single sensor package enabled us to achieve high-level performance by using on average 4-6 sensors. The results from our experiments suggest that IMs can form an excellent complimentary source signal for upper-limb myoelectric prostheses. We trust that multi-modal control solutions have the potential of improving the usability of upper-extremity prostheses in real-life applications.

  13. Synovial Calprotectin: An Inexpensive Biomarker to Exclude a Chronic Prosthetic Joint Infection.

    PubMed

    Wouthuyzen-Bakker, Marjan; Ploegmakers, Joris J W; Ottink, Karsten; Kampinga, Greetje A; Wagenmakers-Huizenga, Lucie; Jutte, Paul C; Kobold, Anneke C M

    2018-04-01

    To diagnose or exclude a chronic prosthetic joint infection (PJI) can be a clinical challenge. Therefore, sensitive and specific biomarkers are needed in the diagnostic work-up. Calprotectin is a protein with antimicrobial properties and is released by activated neutrophils, making it a specific marker for infection. Because of its low costs and ability to obtain a quantitative value as a point of care test, it is an attractive marker to use in clinical practice. In addition, the test is already used in routine care in most hospitals for other indications and therefore easy to implement. Between June 2015 and June 2017 we collected synovial fluid of all consecutive patients who underwent revision surgery of a prosthetic joint because of chronic pain with or without prosthetic loosening. Synovial calprotectin was measured using a lateral flow immunoassay. A PJI was defined by the diagnostic criteria described by the Musculoskeletal Infection Society. Fifty-two patients with chronic pain were included. A PJI was diagnosed in 15 of 52 (29%) patients. The median calprotectin in the PJI group was 859 mg/L (interquartile range 86-1707) vs 7 mg/L (interquartile range 3-25) in the control group (P < .001). With a cut-off value of 50 mg/L, synovial calprotectin showed a sensitivity, specificity, positive predictive value, and negative predictive value of 86.7%, 91.7%, 81.3%, and 94.4%, respectively. Synovial calprotectin is a useful and cheap biomarker to use in the diagnostic work-up of patients with chronic pain, especially to exclude a PJI prior to revision surgery. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Factors which influence necropsy requests: a psychological approach.

    PubMed Central

    Start, R. D.; Hector-Taylor, M. J.; Cotton, D. W.; Startup, M.; Parsons, M. A.; Kennedy, A.

    1992-01-01

    AIMS: To determine which factors influence a clinician's decision to request a necropsy. METHODS: Patient age, confidence in premortem diagnosis, relatives' attitudes, and conditions of necropsy practice were combined factorially (two levels each) in separate medical and surgical questionnaires based on clinical case histories. The interactions between the factors were measured by a repeated measures factorial analysis of variance for each of the two clinical groups. The influence of the clinician's interest in necropsies on these interactions was also examined by a similar method. RESULTS: Necropsies were more likely to be requested on young patients, when diagnostic confidence was low, and when relatives' attitudes were favourable. Conditions of necropsy practice did not affect the likelihood of a request and there was no apparent overall difference in necropsy requests between the two groups of clinicians. The "patient age" and "relatives" factors had less influence on the decision of the surgical group to request necropsy. This was attributed to the opportunity to "see for themselves" at operation and was supported by the finding that surgeons were very likely to request necropsies in the absence of surgical intervention. Clinicians from both groups with a high pre-existing interest in the necropsy were consistently more likely to request necropsies. CONCLUSIONS: The "case history" based questionnaires successfully measured the relative influence of multiple factors in relation to the decision of clinicians to request a necropsy. These findings suggest that any attempt to reverse the decline in necropsy rates should focus on changing the clinician's perception of the value of the modern necropsy. PMID:1556237

  15. Vancomycin-Rifampin Combination Therapy Has Enhanced Efficacy against an Experimental Staphylococcus aureus Prosthetic Joint Infection

    PubMed Central

    Niska, Jared A.; Shahbazian, Jonathan H.; Ramos, Romela Irene; Francis, Kevin P.; Bernthal, Nicholas M.

    2013-01-01

    Treatment of prosthetic joint infections often involves a two-stage exchange, with implant removal and antibiotic spacer placement followed by systemic antibiotic therapy and delayed reimplantation. However, if antibiotic therapy can be improved, one-stage exchange or implant retention may be more feasible, thereby decreasing morbidity and preserving function. In this study, a mouse model of prosthetic joint infection was used in which Staphylococcus aureus was inoculated into a knee joint containing a surgically placed metallic implant extending from the femur. This model was used to evaluate whether combination therapy of vancomycin plus rifampin has increased efficacy compared with vancomycin alone against these infections. On postoperative day 7, vancomycin with or without rifampin was administered for 6 weeks with implant retention. In vivo bioluminescence imaging, ex vivo CFU enumeration, X-ray imaging, and histologic analysis were carried out. We found that there was a marked therapeutic benefit when vancomycin was combined with rifampin compared with vancomycin alone. Taken together, our results suggest that the mouse model used could serve as a valuable in vivo preclinical model system to evaluate and compare efficacies of antibiotics and combinatory therapy for prosthetic joint infections before more extensive studies are carried out in human subjects. PMID:23917317

  16. Factors influencing women's decisions about timing of motherhood.

    PubMed

    Benzies, Karen; Tough, Suzanne; Tofflemire, Karen; Frick, Corine; Faber, Alexandra; Newburn-Cook, Christine

    2006-01-01

    To examine the factors that influence women's decisions about the timing of motherhood from a life span perspective. Qualitative. Large Western Canadian city with a high rate of infants born to women aged 35 years and older. 45 Canadian women aged 20 to 48 years. Independence, a stable relationship, and declining fertility influenced women's decisions about the timing of motherhood. Women integrated child developmental transitions into a projected life plan as they considered the timing of motherhood. Partner readiness and family of origin influences played a lesser role. Delayed childbearing has become more socially acceptable, with subsequent negative connotations associated with younger motherhood. Parental benefits have limited influence on the timing of motherhood. Recognition by nurses of the various and complex factors that influence women's decisions about the timing of motherhood may flag the importance of pregnancy-related counseling for woman across the fertility life span. Policy decision makers must be cognizant of the need for additional high-risk obstetric and neonatal health services when societal norms encourage women to delay childbearing in favor of completing education and establishing a career. (c) 2006, AWHONN, the Association of Women's Health, Obstetric and Neonatal Nurses

  17. Clinical characteristics and outcomes of prosthetic joint infection caused by small colony variant staphylococci.

    PubMed

    Tande, Aaron J; Osmon, Douglas R; Greenwood-Quaintance, Kerryl E; Mabry, Tad M; Hanssen, Arlen D; Patel, Robin

    2014-09-30

    Small colony variants (SCVs) are naturally occurring subpopulations of bacteria. The clinical characteristics and treatment outcomes of patients with prosthetic joint infection (PJI) caused by staphylococcal SCVs are unknown. This study was a retrospective series of 113 patients with staphylococcal PJI, with prospective testing of archived sonicate fluid samples. SCVs were defined using two-investigator review. Treatment failure was defined as (i) subsequent revision surgery for any reason, (ii) PJI after the index surgery, (iii) prosthesis nonreimplantation due to ongoing infection, or (iv) amputation of the affected limb. There were 38 subjects (34%) with SCVs and 75 (66%) with only normal-phenotype (NP) bacteria. Subjects with SCVs were more likely to have been on chronic antimicrobials prior to surgery (P = 0.048), have had prior surgery for PJI (P = 0.03), have had a longer duration of symptoms (P = 0.0003), and have had a longer time since joint implantation (P = 0.007), compared to those with only NP bacteria. Over a median follow-up of 30.6 months, 9 subjects (24%) with SCVs and 23 (32%) with only NP bacteria experienced treatment failure (P = 0.51). Subjects infected with Staphylococcus aureus were more likely to fail than were those infected with Staphylococcus epidermidis (hazard ratio [HR], 4.03; 95% confidence interval [CI], 1.80 to 9.04). While frequently identified in subjects with PJI and associated with several potential predisposing factors, SCVs were not associated with excess treatment failure compared to NP infections in this study, where they were primarily managed with two-stage arthroplasty exchange. Bacteria with the small colony variant (SCV) phenotype are described in small case series as causing persistent or relapsing infection, but there are insufficient data to suggest that they should be managed differently than infection with normal-phenotype bacteria. In an effort to investigate the clinical importance of this phenotype, we

  18. Success rates for initial eradication of peri-prosthetic knee infection treated with a two-stage procedure.

    PubMed

    Kaminski, Andrzej; Citak, Mustafa; Schildhauer, Thomas Armin; Fehmer, Tobias

    2014-01-01

    In Germany, rates of primary total knee arthroplasty procedures and exchange arthroplasty procedures continue to rise. Late-onset peri-prosthetic infection constitutes a serious complication whose management may be dependent upon the spectrum of micro-organisms involved. The aim of this study was to provide a retrospective analysis of the effectiveness of initial eradication measures performed as part of a two-stage procedure. Between 2002 and 2008, a total of 328 patients who had received a first-time diagnosis of chronic peri-prosthetic knee infection following total knee arthroplasty (TKA) subsequently underwent surgery at our clinic. The surgical approach consisted of a two-stage procedure, with the initial procedure consisting of the removal of the prosthesis and radical debridement, followed by insertion of an antibiotic-loaded static spacer. The effectiveness of the procedure was assessed after six weeks, with each patient undergoing a number of clinical and laboratory-based tests, including knee joint aspiration. Staphylococcus aureus strains were responsible for 68% (n=223) of the total number of cases of peri-prosthetic knee infection. 19% of cases (n=62) showed evidence of gram-negative bacteria, while MRSA accounted for 15% (n=49) of cases. Six weeks after completion of the above-named treatment regimen, eradication of infection was considered successful in 289 patients (88.1%). Eradication was unsuccessful in 22% of MRSA infections (n=11) and 7% of MSSA infections (n=23). The treatment regimen outlined in this report is capable of achieving satisfactory results in the management of late-onset peri-prosthetic knee infection, with one exception: patients with infections caused by MRSA showed high failure rates.

  19. Targeting Prostate-Specific Membrane Antigen (PSMA) with F-18-Labeled Compounds: the Influence of Prosthetic Groups on Tumor Uptake and Clearance Profile.

    PubMed

    Bouvet, Vincent; Wuest, Melinda; Bailey, Justin J; Bergman, Cody; Janzen, Nancy; Valliant, John F; Wuest, Frank

    2017-12-01

    Prostate-specific membrane antigen (PSMA) is an important biomarker expressed in the majority of prostate cancers. The favorable positron emission tomography (PET) imaging profile of the PSMA imaging agent 2-(3-(1-carboxy-5-[(6-[ 18 F]fluoro-pyridine-3-carbonyl)-amino]-pentyl)-ureido)-pentane-dioic acid [ 18 F]DCFPyL in preclinical prostate cancer models and in prostate cancer patients stimulated the development and validation of other fluorine-containing PSMA inhibitors to further enhance pharmacokinetics and simplify production methods. Here, we describe the synthesis and radiopharmacological evaluation of various F-18-labeled PSMA inhibitors which were prepared through different prosthetic group chemistry strategies. Prosthetic groups N-succinimidyl-4-[ 18 F]fluorobenzoate ([ 18 F]SFB), 4-[ 18 F]fluorobenzaldehyde, and 2-deoxy-2-[ 18 F]fluoro-D-glucose ([ 18 F]FDG) were used for bioconjugation reactions to PSMA-binding lysine-urea-glutamate scaffold via acylation and oxime formation. All fluorine-containing PSMA inhibitors were tested for their PSMA inhibitory potency in an in vitro competitive binding assay in comparison to an established reference compound [ 125 I]TAAG-PSMA. Tumor uptake and clearance profiles of three F-18-labeled PSMA inhibitors ([ 18 F]4, [ 18 F]7, and [ 18 F]8) were studied with dynamic PET imaging using LNCaP tumor-bearing mice. F-18-labeled PSMA inhibitors were synthesized in 32-69 % radiochemical yields using (1) acylation reaction at the primary amino group of the lysine residue with [ 18 F]SFB and (2) oxime formation with 4-[ 18 F]fluorobenzaldehyde and [ 18 F]FDG using the respective aminooxy-functionalized lysine residue. Compound 7 displayed an IC 50 value of 6 nM reflecting very high affinity for PSMA. Compounds 4 and 8 showed IC 50 values of 13 and 62 nM, respectively. The IC 50 value of reference compound DCFPyL was 13 nM. Dynamic PET imaging revealed the following SUV 60min for radiotracer uptake in PSMA(+) LNCaP tumors: 0

  20. A Compliant Four-bar Linkage Mechanism that Makes the Fingers of a Prosthetic Hand More Impact Resistant

    PubMed Central

    Choi, Kyung Yun; Akhtar, Aadeel; Bretl, Timothy

    2017-01-01

    Repeated mechanical failure due to accidental impact is one of the main reasons why people with upper-limb amputations abandon commercially-available prosthetic hands. To address this problem, we present the design and evaluation of a compliant four-bar linkage mechanism that makes the fingers of a prosthetic hand more impact resistant. Our design replaces both the rigid input and coupler links with a monolithic compliant bone, and replaces the follower link with three layers of pre-stressed spring steel. This design behaves like a conventional four-bar linkage but adds lateral compliance and eliminates a pin joint, which is a main site of failure on impact. Results from free-end and fixed-end impact tests show that, compared to those made with a conventional four-bar linkage, fingers made with our design absorb up to 11% more energy on impact with no mechanical failure. We also show the integration of these fingers in a prosthetic hand that is low-cost, light-weight, and easy to assemble, and that has grasping performance comparable to commercially-available hands. PMID:29527386