Automatic protective vent has fail-safe feature
NASA Technical Reports Server (NTRS)
Dameron, C. E.
1966-01-01
Delayed vent valve system in a mechanical backing pump in a vacuum system allows the pneumatic foreline valve to seal before the pump vent opens. The system is designed to be fail-safe and operate even though there is loss of electrical power.
Fail-safe bidirectional valve driver
NASA Technical Reports Server (NTRS)
Fujimoto, H.
1974-01-01
Cross-coupled diodes are added to commonly used bidirectional valve driver circuit to protect circuit and power supply. Circuit may be used in systems requiring fail-safe bidirectional valve operation, particularly in chemical- and petroleum-processing control systems and computer-controlled hydraulic or pneumatic systems.
NASA Technical Reports Server (NTRS)
Kassel, P. C., Jr.
1978-01-01
A fail safe light activated switch was used as an emergency control link at the Langley Vortex Research Facility. In this facility aircraft models were towed through a still air test chamber by a gasoline powered vehicle which was launched from one end of a 427-meter track and attained velocities to 31 m/sec in the test chamber. A 5 mW HeNe laser with a mechanical copper provided a connecting link with the moving tow vehicle on which a silicon photodiode receiver with a specially designed amplifier provided a fail safe switching action. This system provided an emergency means of stopping the vehicle by turning off the laser to interrupt the power to the vehicle ignition and brake release systems.
Photovoltaic power system reliability considerations
NASA Technical Reports Server (NTRS)
Lalli, V. R.
1980-01-01
An example of how modern engineering and safety techniques can be used to assure the reliable and safe operation of photovoltaic power systems is presented. This particular application is for a solar cell power system demonstration project designed to provide electric power requirements for remote villages. The techniques utilized involve a definition of the power system natural and operating environment, use of design criteria and analysis techniques, an awareness of potential problems via the inherent reliability and FMEA methods, and use of fail-safe and planned spare parts engineering philosophy.
Braking System for Wind Turbines
NASA Technical Reports Server (NTRS)
Krysiak, J. E.; Webb, F. E.
1987-01-01
Operating turbine stopped smoothly by fail-safe mechanism. Windturbine braking systems improved by system consisting of two large steel-alloy disks mounted on high-speed shaft of gear box, and brakepad assembly mounted on bracket fastened to top of gear box. Lever arms (with brake pads) actuated by spring-powered, pneumatic cylinders connected to these arms. Springs give specific spring-loading constant and exert predetermined load onto brake pads through lever arms. Pneumatic cylinders actuated positively to compress springs and disengage brake pads from disks. During power failure, brakes automatically lock onto disks, producing highly reliable, fail-safe stops. System doubles as stopping brake and "parking" brake.
Photovoltaic power system reliability considerations
NASA Technical Reports Server (NTRS)
Lalli, V. R.
1980-01-01
This paper describes an example of how modern engineering and safety techniques can be used to assure the reliable and safe operation of photovoltaic power systems. This particular application was for a solar cell power system demonstration project in Tangaye, Upper Volta, Africa. The techniques involve a definition of the power system natural and operating environment, use of design criteria and analysis techniques, an awareness of potential problems via the inherent reliability and FMEA methods, and use of a fail-safe and planned spare parts engineering philosophy.
Redundant electronic circuit provides fail-safe control
NASA Technical Reports Server (NTRS)
Archer, J. W.
1970-01-01
Circuit using dual control amplifiers and dual position demand potentiometers powered from separate sources is used for reliable hydraulic valve controller that prevents closure of valve when control circuits fail, and maintains valve control to close tolerance for more common modes of controller failure.
Design of a bistable electromagnetic coupling mechanism for underactuated manipulators
NASA Astrophysics Data System (ADS)
Miyuranga Kaluarachchi, Malaka; Ho, Jee-Hou; Yahya, Samer; Teh, Sze-Hong
2018-07-01
Electromagnetic clutches have been widely used in underactuated lightweight manipulator designs as a coupling mechanism due to their advantages of fast activation and electrical controllability. However, an electromagnetic clutch consumes electrical energy continuously during its operation. Furthermore, conventional electromagnetic clutches are not fail-safe in unexpected power failure conditions. These factors have a significant impact on the energy efficiency and the safety of the design, and these are vital aspects for underactuated lightweight manipulators. This paper introduces a bistable electromagnetic coupling mechanism design, with reduced energy consumption and with a fail-safe mechanism. The concept of a bistable electromagnetic mechanism consists of an electromagnet with two permanent magnets. The design has the capability to maintain stable mechanism states, either engaged or disengaged, without a continuous electrical power supply, thus enhancing fail-safety and efficiency. Moreover, the design incorporates the advantages of conventional electromagnetic clutches such as rapid activation and electrical controllability. The experimental results highlight the effectiveness of the proposed mechanism in reducing electric energy consumption. Besides this, a theoretical model is developed and a good correlation is achieved between the theoretical and experimental results. The reduced electric energy consumption and fail-safe design make the bistable electromagnetic mechanism a promising concept for underactuated lightweight manipulators.
77 FR 24362 - Airworthiness Directives; Bombardier, Inc. Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-24
... was prompted by reports of the air driven generator (ADG) failing to power essential buses during... essential buses which, in the event of an emergency, could prevent continued safe flight. DATES: This AD... prevent continued safe flight. This [TCCA] directive mandates the replacement of the ADG GCU. You may...
Power-Factor Controllers: How Safe?
NASA Technical Reports Server (NTRS)
Long, K.; Christian, W.; Kovacik, J.; Grazyk, T.
1985-01-01
Potential safety problems with power-factor controllers (PFC's) evaluated. Based on study of PFCs in use with appliances, report recommends measures to prevent consumers from misapplying these energy saving devices. Device used on such appliances as refrigerators, sewing machines, pumps, hair dryers, and food processors. When misused, they fail to save energy and may cause damage.
Fail-safe fire detection system
NASA Technical Reports Server (NTRS)
Bloam, E. T.
1974-01-01
Fire detection control system continually monitors its own integrity, automatically signals any malfunction, and separately signals fire in any zone being monitored. Should be of interest in fields of chemical and petroleum processing, power generation, equipment testing, and building protection.
30 CFR 77.312 - Fail safe monitoring systems.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Fail safe monitoring systems. 77.312 Section 77... Thermal Dryers § 77.312 Fail safe monitoring systems. Thermal dryer systems and controls shall be protected by a fail safe monitoring system which will safely shut down the system and any related equipment...
30 CFR 77.312 - Fail safe monitoring systems.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Fail safe monitoring systems. 77.312 Section 77... Thermal Dryers § 77.312 Fail safe monitoring systems. Thermal dryer systems and controls shall be protected by a fail safe monitoring system which will safely shut down the system and any related equipment...
30 CFR 77.312 - Fail safe monitoring systems.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Fail safe monitoring systems. 77.312 Section 77... Thermal Dryers § 77.312 Fail safe monitoring systems. Thermal dryer systems and controls shall be protected by a fail safe monitoring system which will safely shut down the system and any related equipment...
30 CFR 77.312 - Fail safe monitoring systems.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Fail safe monitoring systems. 77.312 Section 77... Thermal Dryers § 77.312 Fail safe monitoring systems. Thermal dryer systems and controls shall be protected by a fail safe monitoring system which will safely shut down the system and any related equipment...
30 CFR 77.312 - Fail safe monitoring systems.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Fail safe monitoring systems. 77.312 Section 77... Thermal Dryers § 77.312 Fail safe monitoring systems. Thermal dryer systems and controls shall be protected by a fail safe monitoring system which will safely shut down the system and any related equipment...
30 CFR 75.803 - Fail safe ground check circuits on high-voltage resistance grounded systems.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Fail safe ground check circuits on high-voltage... High-Voltage Distribution § 75.803 Fail safe ground check circuits on high-voltage resistance grounded... shall include a fail safe ground check circuit to monitor continuously the grounding circuit to assure...
30 CFR 75.803 - Fail safe ground check circuits on high-voltage resistance grounded systems.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Fail safe ground check circuits on high-voltage... High-Voltage Distribution § 75.803 Fail safe ground check circuits on high-voltage resistance grounded... shall include a fail safe ground check circuit to monitor continuously the grounding circuit to assure...
30 CFR 75.803 - Fail safe ground check circuits on high-voltage resistance grounded systems.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Fail safe ground check circuits on high-voltage... High-Voltage Distribution § 75.803 Fail safe ground check circuits on high-voltage resistance grounded... shall include a fail safe ground check circuit to monitor continuously the grounding circuit to assure...
30 CFR 75.803 - Fail safe ground check circuits on high-voltage resistance grounded systems.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Fail safe ground check circuits on high-voltage... High-Voltage Distribution § 75.803 Fail safe ground check circuits on high-voltage resistance grounded... shall include a fail safe ground check circuit to monitor continuously the grounding circuit to assure...
Method and apparatus for in-cell vacuuming of radiologically contaminated materials
Spadaro, Peter R.; Smith, Jay E.; Speer, Elmer L.; Cecconi, Arnold L.
1987-01-01
A vacuum air flow operated cyclone separator arrangement for collecting, handling and packaging loose contaminated material in accordance with acceptable radiological and criticality control requirements. The vacuum air flow system includes a specially designed fail-safe prefilter installed upstream of the vacuum air flow power supply. The fail-safe prefilter provides in-cell vacuum system flow visualization and automatically reduces or shuts off the vacuum air flow in the event of an upstream prefilter failure. The system is effective for collecting and handling highly contaminated radiological waste in the form of dust, dirt, fuel element fines, metal chips and similar loose material in accordance with radiological and criticality control requirements for disposal by means of shipment and burial.
30 CFR 77.803 - Fail safe ground check circuits on high-voltage resistance grounded systems.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Fail safe ground check circuits on high-voltage... WORK AREAS OF UNDERGROUND COAL MINES Surface High-Voltage Distribution § 77.803 Fail safe ground check..., resistance grounded systems shall include a fail safe ground check circuit or other no less effective device...
30 CFR 77.803 - Fail safe ground check circuits on high-voltage resistance grounded systems.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Fail safe ground check circuits on high-voltage... WORK AREAS OF UNDERGROUND COAL MINES Surface High-Voltage Distribution § 77.803 Fail safe ground check..., resistance grounded systems shall include a fail safe ground check circuit or other no less effective device...
30 CFR 77.803 - Fail safe ground check circuits on high-voltage resistance grounded systems.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Fail safe ground check circuits on high-voltage... WORK AREAS OF UNDERGROUND COAL MINES Surface High-Voltage Distribution § 77.803 Fail safe ground check..., resistance grounded systems shall include a fail safe ground check circuit or other no less effective device...
30 CFR 77.803 - Fail safe ground check circuits on high-voltage resistance grounded systems.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Fail safe ground check circuits on high-voltage... WORK AREAS OF UNDERGROUND COAL MINES Surface High-Voltage Distribution § 77.803 Fail safe ground check..., resistance grounded systems shall include a fail safe ground check circuit or other no less effective device...
SoS Lablet; Perpetually Available and Secure Information Systems
2015-11-16
settings, people simply err on the safe side and do a lot less sharing, which explains why all pull -based location sharing applications have failed so...number of data centers is raising concerns about their power consumption. Through an NSF GOALI Bruce Krogh and I have investigated the problem by
NASA Technical Reports Server (NTRS)
Bobin, V.; Whitaker, S.
1990-01-01
This paper reports a design technique to make Complex CMOS Gates fail-safe for a class of faults. Two classes of faults are defined. The fail-safe design presented has limited fault-tolerance capability. Multiple faults are also covered.
Investigation of safe-life fail-safe criteria for the space shuttle
NASA Technical Reports Server (NTRS)
1972-01-01
An investigation was made to determine the effects of a safe-life design approach and a fail-safe design approach on the space shuttle booster vehicle structure, and to recommend any changes to the structural design criteria. Two configurations of the booster vehicle were considered, one incorporating a delta wing (B-9U configuration) and the other a swept wing (B-16B configuration). Several major structural components of the booster were studied to determine the fatigue life, safe-life, and fail-safe capabilities of the baseline design. Each component was investigated to determine the practicability of applying a safe-life or fail-safe design philosophy, the changes such design approaches might require, and the impact of these changes on weight, cost, development plans, and performance.
Vehicle electrical system state controller
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bissontz, Jay E.
A motor vehicle electrical power distribution system includes a plurality of distribution sub-systems, an electrical power storage sub-system and a plurality of switching devices for selective connection of elements of and loads on the power distribution system to the electrical power storage sub-system. A state transition initiator provides inputs to control system operation of switching devices to change the states of the power distribution system. The state transition initiator has a plurality of positions selection of which can initiate a state transition. The state transition initiator can emulate a four position rotary ignition switch. Fail safe power cutoff switches providemore » high voltage switching device protection.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bai, Xian-Xu, E-mail: bai@hfut.edu.cn; Wereley, Norman M.
Magnetorheological (MR) energy absorbers (EAs) are an effective adaptive EA technology with which to maximize shock and vibration isolation. However, to realize maximum performance of the semi-active control system, the off-state (i.e., field off) stroking load of the MREA must be minimized at all speeds, and the dynamic range of the MREA must be maximized at high speed. This study presents a fail-safe MREA (MREA-FS) concept that, can produce a greater dynamic range at all piston speeds. A bias damping force is generated in the MREA-FS using permanent magnetic fields, which enables fail-safe behavior in the case of power failure.more » To investigate the feasibility and capability of the MREA-FS in the context of the semi-active control systems, a single-degree-of-freedom base excited rigid payload is mathematically constructed and simulated with skyhook control.« less
On the calculation of low-thrust fail-safe trajectories
NASA Technical Reports Server (NTRS)
Sauer, C. G., Jr.
1975-01-01
A guidance algorithm is developed for a low-thrust spacecraft such that target intercept is possible in spite of premature thrust termination along the trajectory. Such a trajectory is called a 'fail-safe' trajectory and the spacecraft thrust is utilized to minimize the relative target-spacecraft approach speed. The fail-safe guidance algorithm is solved using the concept of a critical thrust plane and a non-critical thrust direction. Several examples of fail-safe guidance are presented for a solar-electric propulsion flyby mission to the comet Encke.
30 CFR 77.902-1 - Fail safe ground check circuits; maximum voltage.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Fail safe ground check circuits; maximum voltage. 77.902-1 Section 77.902-1 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF... OF UNDERGROUND COAL MINES Low- and Medium-Voltage Alternating Current Circuits § 77.902-1 Fail safe...
30 CFR 77.902-1 - Fail safe ground check circuits; maximum voltage.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Fail safe ground check circuits; maximum voltage. 77.902-1 Section 77.902-1 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF... OF UNDERGROUND COAL MINES Low- and Medium-Voltage Alternating Current Circuits § 77.902-1 Fail safe...
30 CFR 77.803-1 - Fail safe ground check circuits; maximum voltage.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Fail safe ground check circuits; maximum voltage. 77.803-1 Section 77.803-1 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF... OF UNDERGROUND COAL MINES Surface High-Voltage Distribution § 77.803-1 Fail safe ground check...
30 CFR 77.803-1 - Fail safe ground check circuits; maximum voltage.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Fail safe ground check circuits; maximum voltage. 77.803-1 Section 77.803-1 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF... OF UNDERGROUND COAL MINES Surface High-Voltage Distribution § 77.803-1 Fail safe ground check...
30 CFR 77.902-1 - Fail safe ground check circuits; maximum voltage.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Fail safe ground check circuits; maximum voltage. 77.902-1 Section 77.902-1 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF... OF UNDERGROUND COAL MINES Low- and Medium-Voltage Alternating Current Circuits § 77.902-1 Fail safe...
30 CFR 77.803-1 - Fail safe ground check circuits; maximum voltage.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Fail safe ground check circuits; maximum voltage. 77.803-1 Section 77.803-1 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF... OF UNDERGROUND COAL MINES Surface High-Voltage Distribution § 77.803-1 Fail safe ground check...
77 FR 21422 - Airworthiness Directives; The Boeing Company Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-10
... the fail-safe interlayer of certain No. 2 and No. 3 glass windows, which could result in loss of the... would hinder the internal or external detailed inspections for fail-safe interlayer cracks, glass pane... this AD only if the non-clear damage hinders the inspection for fail-safe interlayer cracks, glass pane...
30 CFR 77.803-1 - Fail safe ground check circuits; maximum voltage.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Fail safe ground check circuits; maximum... OF UNDERGROUND COAL MINES Surface High-Voltage Distribution § 77.803-1 Fail safe ground check circuits; maximum voltage. The maximum voltage used for ground check circuits under § 77.803 shall not...
30 CFR 77.803-1 - Fail safe ground check circuits; maximum voltage.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Fail safe ground check circuits; maximum... OF UNDERGROUND COAL MINES Surface High-Voltage Distribution § 77.803-1 Fail safe ground check circuits; maximum voltage. The maximum voltage used for ground check circuits under § 77.803 shall not...
Study of fail-safe abort system for an actively cooled hypersonic aircraft, volume 2
NASA Technical Reports Server (NTRS)
Peeples, M. E.; Herring, R. L.
1976-01-01
Conceptual designs of a fail-safe abort system for hydrogen fueled actively cooled high speed aircraft are examined. The fail-safe concept depends on basically three factors: (1) a reliable method of detecting a failure or malfunction in the active cooling system, (2) the optimization of abort trajectories which minimize the descent heat load to the aircraft, and (3) fail-safe thermostructural concepts to minimize both the weight and the maximum temperature the structure will reach during descent. These factors are examined and promising approaches are evaluated based on weight, reliability, ease of manufacture and cost.
When the science fails and the ethics works: 'Fail-safe' ethics in the FEM-PrEP study.
Kingori, Patricia
2015-12-01
This paper will explore the concept of 'fail safe' ethics in the FEM PrEP trial, and the practice of research and ethics on the ground. FEM-PrEP examined the efficacy of PrEP in African women after promising outcomes in research conducted with MSM. This was a hugely optimistic time and FEM-PrEP was mobilised using rights-based ethical arguments that women should have access to PrEP. This paper will present data collected during an ethnographic study of frontline research workers involved in FEM-PrEP. During our discussions, 'fail-safe' ethics emerged as concept that encapsulated their confidence that their ethics could not fail. However, in 2011, FEM-PrEP was halted and deemed a failure. The women involved in the study were held responsible because contrary to researcher's expectations they were not taking the oral PrEP being researched. This examination of FEM-PrEP will show that ethical arguments are increasingly deployed to mobilise, maintain and in some cases stop trials in ways which, at times, are superseded or co-opted by other interests. While promoting the interests of women, rights-based approaches are argued to indirectly justify the continuation of individualised, biomedical interventions which have been problematic in other women-centred trials. In this examination of FEM-PrEP, the rights-based approach obscured: ethical concerns beyond access to PrEP; the complexities of power relationships between donor and host countries; the operations of the HIV industry in research-saturated areas and the cumulative effect of unfilled expectations in HIV research and how this has shaped ideas of research and ethics.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-24
... and corrosion to an area within five inches of the fail-safe strap. Revision 2 of this service.... The existing AD currently requires inspections to detect cracking or corrosion of the fail-safe straps... corrective actions. Since we issued that AD, we have received additional reports of cracks in 51 fail-safe...
NASA Technical Reports Server (NTRS)
Pirello, C. J.; Herring, R. L.
1976-01-01
Conceptual designs of a fail-safe abort system for hydrogen fueled actively cooled high speed aircraft are examined. The fail-safe concept depends on basically three factors: (1) a reliable method of detecting a failure or malfunction in the active cooling system, (2) the optimization of abort trajectories which minimize the descent heat load to the aircraft, and (3) fail-safe thermostructural concepts to minimize both the weight and the maximum temperature the structure will reach during descent. These factors are examined and promising approaches are evaluated based on weight, reliability, ease of manufacture and cost.
29 CFR 1910.179 - Overhead and gantry cranes.
Code of Federal Regulations, 2010 CFR
2010-07-01
... adequately guarded or isolated. (40) Fail-safe means a provision designed to automatically stop or safely... shall be capable of maintaining safe lowering speeds of rated loads. (ii) The control braking means... the crane operator. (viii) Automatic cranes shall be so designed that all motions shall fail-safe if...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-29
... withstand fail-safe loads. DATES: We must receive comments on this proposed AD by August 15, 2011. ADDRESSES... pressurization and the inability of the airplane fuselage to withstand fail-safe loads. Actions Since Existing AD... withstand fail-safe loads. Compliance (f) You are responsible for having the actions required by this AD...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-07
... removing corrosion from fail-safe straps. We have received Boeing Service Bulletin 767-53A0100, Revision 3.... That AD currently requires inspections to detect cracking or corrosion of the fail-safe straps between... cracks in 51 fail-safe straps on 41 airplanes; we have also received a report of a crack found in the ``T...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-07
... are proposing this AD to detect and correct cracking in the fail-safe interlayer of certain No. 2 and... to detect and correct cracking in the fail-safe interlayer of certain No. 2 and No. 3 glass windows... cracking in the fail-safe interlayer of certain No. 2 and No. 3 glass windows, which could result in loss...
Fail-safe reactivity compensation method for a nuclear reactor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nygaard, Erik T.; Angelo, Peter L.; Aase, Scott B.
The present invention relates generally to the field of compensation methods for nuclear reactors and, in particular to a method for fail-safe reactivity compensation in solution-type nuclear reactors. In one embodiment, the fail-safe reactivity compensation method of the present invention augments other control methods for a nuclear reactor. In still another embodiment, the fail-safe reactivity compensation method of the present invention permits one to control a nuclear reaction in a nuclear reactor through a method that does not rely on moving components into or out of a reactor core, nor does the method of the present invention rely on themore » constant repositioning of control rods within a nuclear reactor in order to maintain a critical state.« less
Vicentini, Federico; Pedrocchi, Nicola; Malosio, Matteo; Molinari Tosatti, Lorenzo
2014-09-01
Robot-assisted neurorehabilitation often involves networked systems of sensors ("sensory rooms") and powerful devices in physical interaction with weak users. Safety is unquestionably a primary concern. Some lightweight robot platforms and devices designed on purpose include safety properties using redundant sensors or intrinsic safety design (e.g. compliance and backdrivability, limited exchange of energy). Nonetheless, the entire "sensory room" shall be required to be fail-safe and safely monitored as a system at large. Yet, sensor capabilities and control algorithms used in functional therapies require, in general, frequent updates or re-configurations, making a safety-grade release of such devices hardly sustainable in cost-effectiveness and development time. As such, promising integrated platforms for human-in-the-loop therapies could not find clinical application and manufacturing support because of lacking in the maintenance of global fail-safe properties. Under the general context of cross-machinery safety standards, the paper presents a methodology called SafeNet for helping in extending the safety rate of Human Robot Interaction (HRI) systems using unsafe components, including sensors and controllers. SafeNet considers, in fact, the robotic system as a device at large and applies the principles of functional safety (as in ISO 13489-1) through a set of architectural procedures and implementation rules. The enabled capability of monitoring a network of unsafe devices through redundant computational nodes, allows the usage of any custom sensors and algorithms, usually planned and assembled at therapy planning-time rather than at platform design-time. A case study is presented with an actual implementation of the proposed methodology. A specific architectural solution is applied to an example of robot-assisted upper-limb rehabilitation with online motion tracking. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
New Developments in FPGA: SEUs and Fail-Safe Strategies from the NASA Goddard Perspective
NASA Technical Reports Server (NTRS)
Berg, Melanie D.; Label, Kenneth A.; Pellish, Jonathan
2016-01-01
It has been shown that, when exposed to radiation environments, each Field Programmable Gate Array (FPGA) device has unique error signatures. Subsequently, fail-safe and mitigation strategies will differ per FPGA type. In this session several design approaches for safe systems will be presented. It will also explore the benefits and limitations of several mitigation techniques. The intention of the presentation is to provide information regarding FPGA types, their susceptibilities, and proven fail-safe strategies; so that users can select appropriate mitigation and perform the required trade for system insertion. The presentation will describe three types of FPGA devices and their susceptibilities in radiation environments.
New Developments in FPGA: SEUs and Fail-Safe Strategies from the NASA Goddard Perspective
NASA Technical Reports Server (NTRS)
Berg, Melanie D.; LaBel, Kenneth; Pellish, Jonathan
2015-01-01
It has been shown that, when exposed to radiation environments, each Field Programmable Gate Array (FPGA) device has unique error signatures. Subsequently, fail-safe and mitigation strategies will differ per FPGA type. In this session several design approaches for safe systems will be presented. It will also explore the benefits and limitations of several mitigation techniques. The intention of the presentation is to provide information regarding FPGA types, their susceptibilities, and proven fail-safe strategies; so that users can select appropriate mitigation and perform the required trade for system insertion. The presentation will describe three types of FPGA devices and their susceptibilities in radiation environments.
The IRAC Shutter Mechanism: Residual Magnetism and the Rotary Solenoid
NASA Technical Reports Server (NTRS)
Schwinger, Scott; Hakun, Claef; Brown, Gary; Blumenstock, Ken
2002-01-01
The Infrared Array Camera (IRAC) Shutter mechanism was originally presented in the paper, 'A Low Power Cryogenic Shutter Mechanism for Use on Infrared Imagers' at the 34th Aerospace Mechanisms Symposium, May 2000. At that time, the shutter was believed to be performing flawlessly and there was every indication it would continue to do so. In early spring of 2001, the calibration shutter, a rotary solenoid designed to be fail-safe open, remained in a closed state with no power to the electromagnetic coils. The ensuing investigation, subsequent testing, proposed remedy, and lessons learned are the focus of this paper.
Evolution of the Hubble Space Telescope Safing Systems
NASA Technical Reports Server (NTRS)
Pepe, Joyce; Myslinski, Michael
2006-01-01
The Hubble Space Telescope (HST) was launched on April 24 1990, with an expected lifespan of 15 years. Central to the spacecraft design was the concept of a series of on-orbit shuttle servicing missions permitting astronauts to replace failed equipment, update the scientific instruments and keep the HST at the forefront of astronomical discoveries. One key to the success of the Hubble mission has been the robust Safing systems designed to monitor the performance of the observatory and to react to keep the spacecraft safe in the event of equipment anomaly. The spacecraft Safing System consists of a range of software tests in the primary flight computer that evaluate the performance of mission critical hardware, safe modes that are activated when the primary control mode is deemed inadequate for protecting the vehicle, and special actions that the computer can take to autonomously reconfigure critical hardware. The HST Safing System was structured to autonomously detect electrical power system, data management system, and pointing control system malfunctions and to configure the vehicle to ensure safe operation without ground intervention for up to 72 hours. There is also a dedicated safe mode computer that constantly monitors a keep-alive signal from the primary computer. If this signal stops, the safe mode computer shuts down the primary computer and takes over control of the vehicle, putting it into a safe, low-power configuration. The HST Safing system has continued to evolve as equipment has aged, as new hardware has been installed on the vehicle, and as the operation modes have matured during the mission. Along with the continual refinement of the limits used in the safing tests, several new tests have been added to the monitoring system, and new safe modes have been added to the flight software. This paper will focus on the evolution of the HST Safing System and Safing tests, and the importance of this evolution to prolonging the science operations of the telescope.
Hong, Namki; Kim, Chang Oh; Youm, Yoosik; Kim, Hyeon Chang; Rhee, Yumie
2018-06-01
In a community-dwelling elderly cohort (Korean Urban Rural Elderly), low peak jump power was associated with elevated odds of dysmobility syndrome and its components, independent of age and comorbidities. Jump power measurement improved discrimination of individuals with dysmobility syndrome when added to conventional risk factors. Dysmobility syndrome was proposed to encompass the risks affecting musculoskeletal outcomes. Jump power measurement is a safe, reproducible high-intensity test for physical function in elderly. However, the relationship between jump power and dysmobility syndrome remains unknown. A total of 1369 subjects (mean 71.6 years; women, 66%) were analyzed from a community-based cohort. Dysmobility syndrome was defined as the presence of ≥ 3 factors among falls in the preceding year, low lean mass, high fat mass, osteoporosis, low grip strength, and low timed get-up-and-go (TUG) performance. Subjects were grouped into tertiles of jump power relative to weight based on sex-stratified cutoffs (32.4 and 27.6 W/kg in men; 23.9 and 19.9 W/kg in women) or into the failed-to-jump group. The prevalence of dysmobility syndrome was 20% overall, increasing from the highest (T1) to lowest (T3) jump power tertile (1, 11, 15% in men; 11, 16, 39% in women) and the failed-to-jump group (39% in men; 48% in women). Low jump power or failed-to-jump was associated with elevated odds of dysmobility syndrome (T3 vs. T1, adjusted odds ratio [aOR] 4.35, p < 0.001; failed-to-jump vs. T1, aOR 7.60, p < 0.001) and its components including falls, low lean mass, high fat mass, and poor TUG performance but not osteoporosis after adjustment for covariates. Jump power modestly discriminated dysmobility syndrome (area under the curve [AUC], 0.71, p < 0.001), which improved discriminatory performance when added to conventional risk factors (AUC, from 0.75 to 0.79, p < 0.001). Low peak jump power was associated with elevated odds of dysmobility syndrome and its components, independent of age and comorbidities.
New Developments in FPGA Devices: SEUs and Fail-Safe Strategies from the NASA Goddard Perspective
NASA Technical Reports Server (NTRS)
Berg, Melanie; LaBel, Kenneth; Pellish, Jonathan
2016-01-01
It has been shown that, when exposed to radiation environments, each Field Programmable Gate Array (FPGA) device has unique error signatures. Subsequently, fail-safe and mitigation strategies will differ per FPGA type. In this session several design approaches for safe systems will be presented. It will also explore the benefits and limitations of several mitigation techniques. The intention of the presentation is to provide information regarding FPGA types, their susceptibilities, and proven fail-safe strategies; so that users can select appropriate mitigation and perform the required trade for system insertion. The presentation will describe three types of FPGA devices and their susceptibilities in radiation environments.
NASA Technical Reports Server (NTRS)
Holden, D. G.
1975-01-01
Hard Over Monitoring Equipment (HOME) has been designed to complement and enhance the flight safety of a flight research helicopter. HOME is an independent, highly reliable, and fail-safe special purpose computer that monitors the flight control commands issued by the flight control computer of the helicopter. In particular, HOME detects the issuance of a hazardous hard-over command for any of the four flight control axes and transfers the control of the helicopter to the flight safety pilot. The design of HOME incorporates certain reliability and fail-safe enhancement design features, such as triple modular redundancy, majority logic voting, fail-safe dual circuits, independent status monitors, in-flight self-test, and a built-in preflight exerciser. The HOME design and operation is described with special emphasis on the reliability and fail-safe aspects of the design.
Fail-safe system for activity cooled supersonic and hypersonic aircraft. [using liquid hydrogen fuel
NASA Technical Reports Server (NTRS)
Jones, R. A.; Braswell, D. O.; Richie, C. B.
1975-01-01
A fail-safe-system concept was studied as an alternative to a redundant active cooling system for supersonic and hypersonic aircraft which use the heat sink of liquid-hydrogen fuel for cooling the aircraft structure. This concept consists of an abort maneuver by the aircraft and a passive thermal protection system (TPS) for the aircraft skin. The abort manuever provides a low-heat-load descent from normal cruise speed to a lower speed at which cooling is unnecessary, and the passive TPS allows the aircraft skin to absorb the abort heat load without exceeding critical skin temperature. On the basis of results obtained, it appears that this fail-safe-system concept warrants further consideration, inasmuch as a fail-safe system could possibly replace a redundant active cooling system with no increase in weight and would offer other potential advantages.
Fluid check valve has fail-safe feature
NASA Technical Reports Server (NTRS)
Gaul, L. C.
1965-01-01
Check valve ensures unidirectional fluid flow and, in case of failure, vents the downstream fluid to the atmosphere and gives a positive indication of malfunction. This dual valve consists of a master check valve and a fail-safe valve.
The AP1000{sup R} nuclear power plant innovative features for extended station blackout mitigation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vereb, F.; Winters, J.; Schulz, T.
2012-07-01
Station Blackout (SBO) is defined as 'a condition wherein a nuclear power plant sustains a loss of all offsite electric power system concurrent with turbine trip and unavailability of all onsite emergency alternating current (AC) power system. Station blackout does not include the loss of available AC power to buses fed by station batteries through inverters or by alternate AC sources as defined in this section, nor does it assume a concurrent single failure or design basis accident...' in accordance with Reference 1. In this paper, the innovative features of the AP1000 plant design are described with their operation inmore » the scenario of an extended station blackout event. General operation of the passive safety systems are described as well as the unique features which allow the AP1000 plant to cope for at least 7 days during station blackout. Points of emphasis will include: - Passive safety system operation during SBO - 'Fail-safe' nature of key passive safety system valves; automatically places the valve in a conservatively safe alignment even in case of multiple failures in all power supply systems, including normal AC and battery backup - Passive Spent Fuel Pool cooling and makeup water supply during SBO - Robustness of AP1000 plant due to the location of key systems, structures and components required for Safe Shutdown - Diverse means of supplying makeup water to the Passive Containment Cooling System (PCS) and the Spent Fuel Pool (SFP) through use of an engineered, safety-related piping interface and portable equipment, as well as with permanently installed onsite ancillary equipment. (authors)« less
NASA Technical Reports Server (NTRS)
Haas, L. A., Sr.
1976-01-01
The Fail-Safe Abort System TEMPerature Analysis Program, (FASTEMP), user's manual is presented. This program was used to analyze fail-safe abort systems for an actively cooled hypersonic aircraft. FASTEMP analyzes the steady state or transient temperature response of a thermal model defined in rectangular, cylindrical, conical and/or spherical coordinate system. FASTEMP provides the user with a large selection of subroutines for heat transfer calculations. The various modes of heat transfer available from these subroutines are: heat storage, conduction, radiation, heat addition or generation, convection, and fluid flow.
Performance of a fail-safe system to follow up abnormal mammograms in primary care.
Grossman, Ellie; Phillips, Russell S; Weingart, Saul N
2010-09-01
Missed and delayed breast cancer diagnoses are major sources of potential harm to patients and medical malpractice liability in the United States. Follow-up of abnormal mammogram results is an essential but challenging component of safe breast care. To explore the value of an inexpensive method to follow up abnormal test results, we examined a paper-based fail-safe system. We examined a fail-safe system used to follow up abnormal mammograms at a primary care practice at an urban teaching hospital. We analyzed all abnormal mammogram reports and clinicians' responses to follow-up reminders. We characterized potential lapses identified in this system and used regression models to identify patient, provider, and test result characteristics associated with such lapses. Clinicians responded to fail-safe reminders for 92% of 948 abnormal mammograms. Clinicians reported that they were unaware of the abnormal result in 8% of cases and that there was no follow-up plan in place for 3% of cases. Clinicians with more years of experience were more likely to be aware of the abnormal result (odds of being unaware per incremental year in practice, 0.92; 95% confidence interval, 0.88-0.97) and were more likely to have a follow-up plan. A paper-based fail-safe system for abnormal mammograms is feasible in a primary care practice. However, special care is warranted to ensure full clinician adherence and address staff transitions and trainee-related issues.
The 200-kilowatt wind turbine project
NASA Technical Reports Server (NTRS)
1978-01-01
The three 200 kilowatt wind turbines described, compose the first of three separate systems. Proposed wind turbines of the two other systems, although similar in design, are larger in both physical size and rated power generation. The overall objective of the project is to obtain early operation and performance data while gaining initial experience in the operation of large, horizontal-axis wind turbines in typical utility environments. Several of the key issues addressed include the following: (1) impact of the variable power output (due to varying wind speeds) on the utility grid (2) compatibility with utility requirements (voltage and frequency control of generated power) (3) demonstration of unattended, fail-safe operation (4) reliability of the wind turbine system (5) required maintenance and (6) initial public reaction and acceptance.
NASA Technical Reports Server (NTRS)
Diftler, Myron A.; Hulse, Aaron
2010-01-01
A magnetostrictive brake has been designed as a more energy-efficient alternative to a magnetic fail-safe brake in a robot. (In the specific application, failsafe signifies that the brake is normally engaged; that is, power must be supplied to allow free rotation.) The magnetic failsafe brake must be supplied with about 8 W of electric power to initiate and maintain disengagement. In contrast, the magnetostrictive brake, which would have about the same dimensions and the same torque rating as those of the magnetic fail-safe brake, would demand only about 2 W of power for disengagement. The brake (see figure) would include a stationary base plate and a hub mounted on the base plate. Two solenoid assemblies would be mounted in diametrically opposed recesses in the hub. The cores of the solenoids would be made of the magnetostrictive alloy Terfenol-D or equivalent. The rotating part of the brake would be a ring-and spring- disk subassembly. By means of leaf springs not shown in the figure, this subassembly would be coupled with the shaft that the brake is meant to restrain. With no power supplied to the solenoids, a permanent magnet would pull axially on a stepped disk and on a shelf in the hub, causing the ring to be squeezed axially between the stepped disk and the hub. The friction associated with this axial squeeze would effect the braking action. Supplying electric power to the solenoids would cause the magnetostrictive cylinders to push radially inward against a set of wedges that would be in axial contact with the stepped disk. The wedges would convert the radial magnetostrictive strain to a multiplied axial displacement of the stepped disk. This axial displacement would be just large enough to lift the stepped disk, against the permanent magnetic force, out of contact with the ring. The ring would then be free to turn because it would no longer be squeezed axially between the stepped disk and the hub.
77 FR 29857 - Airworthiness Directives; The Boeing Company Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-21
... of cabin pressurization and the inability of the fuselage to withstand fail-safe loads. DATES: This... cabin pressurization and the inability of the fuselage to withstand fail-safe loads. (f) Compliance You... reference of certain publications listed in the AD as of June 25, 2012. ADDRESSES: For service information...
76 FR 82210 - Airworthiness Directives; The Boeing Company Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-30
... fuse pins that can fail earlier than the previously determined safe life limit of the pins. A fractured... retract actuator fuse pins that can fail earlier than previously determined safe life limit of the pins. A... Friday, except Federal holidays. For service information identified in this proposed AD, contact Boeing...
77 FR 37781 - Airworthiness Directives; The Boeing Company Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-25
... actuator fuse pins that can fail earlier than the previously determined safe life limit of the pins. A... that can fail earlier than the previously determined safe life limit of the pins. A fractured retract... July 30, 2012. ADDRESSES: For service information identified in this AD, contact Boeing Commercial...
Adaptive voting computer system
NASA Technical Reports Server (NTRS)
Koczela, L. J.; Wilgus, D. S. (Inventor)
1974-01-01
A computer system is reported that uses adaptive voting to tolerate failures and operates in a fail-operational, fail-safe manner. Each of four computers is individually connected to one of four external input/output (I/O) busses which interface with external subsystems. Each computer is connected to receive input data and commands from the other three computers and to furnish output data commands to the other three computers. An adaptive control apparatus including a voter-comparator-switch (VCS) is provided for each computer to receive signals from each of the computers and permits adaptive voting among the computers to permit the fail-operational, fail-safe operation.
Universal power transistor base drive control unit
Gale, Allan R.; Gritter, David J.
1988-01-01
A saturation condition regulator system for a power transistor which achieves the regulation objectives of a Baker clamp but without dumping excess base drive current into the transistor output circuit. The base drive current of the transistor is sensed and used through an active feedback circuit to produce an error signal which modulates the base drive current through a linearly operating FET. The collector base voltage of the power transistor is independently monitored to develop a second error signal which is also used to regulate base drive current. The current-sensitive circuit operates as a limiter. In addition, a fail-safe timing circuit is disclosed which automatically resets to a turn OFF condition in the event the transistor does not turn ON within a predetermined time after the input signal transition.
Universal power transistor base drive control unit
Gale, A.R.; Gritter, D.J.
1988-06-07
A saturation condition regulator system for a power transistor is disclosed which achieves the regulation objectives of a Baker clamp but without dumping excess base drive current into the transistor output circuit. The base drive current of the transistor is sensed and used through an active feedback circuit to produce an error signal which modulates the base drive current through a linearly operating FET. The collector base voltage of the power transistor is independently monitored to develop a second error signal which is also used to regulate base drive current. The current-sensitive circuit operates as a limiter. In addition, a fail-safe timing circuit is disclosed which automatically resets to a turn OFF condition in the event the transistor does not turn ON within a predetermined time after the input signal transition. 2 figs.
30 CFR 77.902-1 - Fail safe ground check circuits; maximum voltage.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Fail safe ground check circuits; maximum voltage. 77.902-1 Section 77.902-1 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF... ground check circuits; maximum voltage. The maximum voltage used for ground check circuits under § 77.902...
30 CFR 77.902-1 - Fail safe ground check circuits; maximum voltage.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Fail safe ground check circuits; maximum voltage. 77.902-1 Section 77.902-1 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF... ground check circuits; maximum voltage. The maximum voltage used for ground check circuits under § 77.902...
Instrumentation and control system architecture of ECRH SST1
NASA Astrophysics Data System (ADS)
Patel, Harshida; Patel, Jatin; purohit, Dharmesh; Shukla, B. K.; Babu, Rajan; Mistry, Hardik
2017-07-01
The Electron Cyclotron Resonance Heating (ECRH) system is an important heating system for the reliable start-up of tokamak. The 42GHz and 82.6GHz Gyrotron based ECRH systems are used in tokomaks SST-1 and Aditya to carry out ECRH related experiments. The Gyrotrons are high power microwave tubes used as a source for ECRH systems. The Gyrotrons need to be handled with optimum care right from the installation to its Full parameter control operation. The Gyrotrons are associated with the subsystems like: High voltage power supplies (Beam voltage and anode voltage), dedicated crowbar system, magnet, filament and ion pump power supplies and cooling system. The other subsystems are transmission line, launcher and dummy load. A dedicated VME based data acquisition & control (DAC) system is developed to operate and control the Gyrotron and its associated sub system. For the safe operation of Gyrotron, two level interlocks with fail-safe logic are developed. Slow signals that are operated in scale of millisecond range are programmed through software and hardware interlock in scale of microsecond range are designed and developed indigenously. Water-cooling and the associated interlock are monitored and control by data logger with independent human machine interface.
Fail-Safe Magnetic Bearing Controller Demonstrated Successfully
NASA Technical Reports Server (NTRS)
Choi, Benjamin B.; Provenza, Andrew J.
2001-01-01
The Structural Mechanics and Dynamics Branch has successfully demonstrated a fail-safe controller for the Fault-Tolerant Magnetic Bearing rig at the NASA Glenn Research Center. The rotor is supported by two 8-pole redundant radial bearings, and coil failing situations are simulated by manually shutting down their control current commands from the controller cockpit. The effectiveness of the controller was demonstrated when only two active coils from each radial bearing could be used (that is, 14 coils failed). These remaining two coils still levitated the rotor and spun it without losing stability or desired position up to the maximum allowable speed of 20,000 rpm.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-13
... must provide fail-safe operations during coupled maneuvers. The demonstration of fail-safe operations... receive your comments by February 11, 2011. ADDRESSES: You must mail or deliver two copies of your... your comments: Docket No. SW023. You can inspect comments in the Docket on weekdays, except Federal...
A Statistical Simulation Approach to Safe Life Fatigue Analysis of Redundant Metallic Components
NASA Technical Reports Server (NTRS)
Matthews, William T.; Neal, Donald M.
1997-01-01
This paper introduces a dual active load path fail-safe fatigue design concept analyzed by Monte Carlo simulation. The concept utilizes the inherent fatigue life differences between selected pairs of components for an active dual path system, enhanced by a stress level bias in one component. The design is applied to a baseline design; a safe life fatigue problem studied in an American Helicopter Society (AHS) round robin. The dual active path design is compared with a two-element standby fail-safe system and the baseline design for life at specified reliability levels and weight. The sensitivity of life estimates for both the baseline and fail-safe designs was examined by considering normal and Weibull distribution laws and coefficient of variation levels. Results showed that the biased dual path system lifetimes, for both the first element failure and residual life, were much greater than for standby systems. The sensitivity of the residual life-weight relationship was not excessive at reliability levels up to R = 0.9999 and the weight penalty was small. The sensitivity of life estimates increases dramatically at higher reliability levels.
van Woerkom, Arthur Ernst
2017-01-01
It is proposed that lithium's therapeutic effects occur indirectly by augmenting a cascade of protective "fail-safe" pathways pre-configured to activate in response to a dangerous low cell [Mg ++ ] situation, eg, posttraumatic brain injury, alongside relative cell adenosine triphosphate depletion. Lithium activates cell protection, as it neatly mimics a lowered intracellular [Mg ++ ] level.
Towards a damage tolerance philosophy for composite materials and structures
NASA Technical Reports Server (NTRS)
O'Brien, T. Kevin
1990-01-01
A damage-threshold/fail-safe approach is proposed to ensure that composite structures are both sufficiently durable for economy of operation, as well as adequately fail-safe or damage tolerant for flight safety. Matrix cracks are assumed to exist throughout the off-axis plies. Delamination onset is predicted using a strain energy release rate characterization. Delamination growth is accounted for in one of three ways: either analytically, using delamination growth laws in conjunction with strain energy release rate analyses incorporating delamination resistance curves; experimentally, using measured stiffness loss; or conservatively, assuming delamination onset corresponds to catastrophic delamination growth. Fail-safety is assessed by accounting for the accumulation of delaminations through the thickness. A tension fatigue life prediction for composite laminates is presented as a case study to illustrate how this approach may be implemented. Suggestions are made for applying the damage-threshold/fail-safe approach to compression fatigue, tension/compression fatigue, and compression strength following low velocity impact.
Towards a damage tolerance philosophy for composite materials and structures
NASA Technical Reports Server (NTRS)
Obrien, T. Kevin
1988-01-01
A damage-threshold/fail-safe approach is proposed to ensure that composite structures are both sufficiently durable for economy of operation, as well as adequately fail-safe or damage tolerant for flight safety. Matrix cracks are assumed to exist throughout the off-axis plies. Delamination onset is predicted using a strain energy release rate characterization. Delamination growth is accounted for in one of three ways: either analytically, using delamination growth laws in conjunction with strain energy release rate analyses incorporating delamination resistance curves; experimentally, using measured stiffness loss; or conservatively, assuming delamination onset corresponds to catastrophic delamination growth. Fail-safety is assessed by accounting for the accumulation of delaminations through the thickness. A tension fatigue life prediction for composite laminates is presented as a case study to illustrate how this approach may be implemented. Suggestions are made for applying the damage-threshold/fail-safe approach to compression fatigue, tension/compression fatigue, and compression strength following low velocity impact.
F-15 HiDEC in flight over Mojave desert
NASA Technical Reports Server (NTRS)
1990-01-01
NASA's F-15 HIDEC (Highly Integrated Digital Electronic Control) research aircraft cruises over California's Mojave Desert at sunset on a flight out of the Dryden Flight Research Center, Edwards, California. The aircraft was used to carry out research on engine and flight control systems and most recently demonstrated the use of computer-assisted engine controls as a means of landing an aircraft safely with only engine power if its normal control surfaces such as elevators, rudders or ailerons are disabled. The aircraft also tested and evaluated a computerized self-repair flight control system for the Air Force that detects damaged or failed flight control surfaces, and then reconfigures undamaged flight surfaces so the mission can continue or the aircraft is landed safely. Nearly all research being carried out in the HIDEC program is applicable to future civilian and military aircraft.
Fail-safe designs for large capacity battery systems
Kim, Gi-Heon; Smith, Kandler; Ireland, John; Pesaran, Ahmad A.; Neubauer, Jeremy
2016-05-17
Fail-safe systems and design methodologies for large capacity battery systems are disclosed. The disclosed systems and methodologies serve to locate a faulty cell in a large capacity battery, such as a cell having an internal short circuit, determine whether the fault is evolving, and electrically isolate the faulty cell from the rest of the battery, preventing further electrical energy from feeding into the fault.
2006-09-01
MONITORING , AND PROGNOSTICS Alireza R. Behbahani Controls / Engine Health Management Turbine Engine Division / PRTS U.S. Air Force Research...Technical Report 2005. 8. Greitzer, Frank et al, “Gas Turbine Engine Health Monitoring and Prognostics ”, International Society of Logistics (SOLE...AFRL-PR-WP-TP-2007-217 NEED FOR ROBUST SENSORS FOR INHERENTLY FAIL-SAFE GAS TURBINE ENGINE CONTROLS, MONITORING , AND PROGNOSTICS (POSTPRINT
(abstract) The Design of a Benign Fail-safe Mechanism Using a Low-melting-point Metal Alloy Coupler
NASA Technical Reports Server (NTRS)
Blomquist, Richard S.
1995-01-01
Because the alpha proton X ray spectrometer (APXS) sensor head on the Mars Pathfinder rover, Sojourner, is placed on Martian soil by the deployment mechanism (ADM), the rover would be crippled if the actuator fails when the mechanism is in its deployed position, as rover ground clearance is then reduced to zero. This paper describes the unique fail-safe mounted on the ADM, especially the use of a low-temperature-melting alloy as a coupler device. The final form of the design is a low-melting-point metal pellet coupler, made from Cerrobend, in parallel with a Negator spring pack. In its solid state, the metal rigidly connects the driver (the actuator) and the driven part (the mechanism). When commanded, a strip heater wrapped around the coupler melts the metal pellet (at 60(deg)C), allowing the driven part to turn independent of the driver. The Negator spring retracts the mechanism to its fully stowed position. This concept meets all the design criteria, and provides an added benefit. When the metal hardens the coupler once again rigidly connects the actuator and the mechanism. The concept presented here can easily be applied to other applications. Anywhere release devices are needed, low-melting-point couplers can be considered. The issues to be concerned with are thermal isolation, proper setting of the parts before actuation, and possible outgassing concerns. However, when these issues are overcome, the resulting release mechanism can promise to be the most light, simple, power conserving alternative available.
Turbine vane segment and impingement insert configuration for fail-safe impingement insert retention
Burdgick, Steven Sebastian; Kellock, Iain Robertson
2003-05-13
An impingement insert sleeve is provided that is adapted to be disposed in a coolant cavity defined through a stator vane. The insert has a generally open inlet end and first and second pairs of diametrically opposed side walls, and at least one fail-safe tab defined at a longitudinal end of the insert for limiting radial displacement of the insert with respect to the stator vane.
Publication Bias in Meta-Analysis: Confidence Intervals for Rosenthal's Fail-Safe Number.
Fragkos, Konstantinos C; Tsagris, Michail; Frangos, Christos C
2014-01-01
The purpose of the present paper is to assess the efficacy of confidence intervals for Rosenthal's fail-safe number. Although Rosenthal's estimator is highly used by researchers, its statistical properties are largely unexplored. First of all, we developed statistical theory which allowed us to produce confidence intervals for Rosenthal's fail-safe number. This was produced by discerning whether the number of studies analysed in a meta-analysis is fixed or random. Each case produces different variance estimators. For a given number of studies and a given distribution, we provided five variance estimators. Confidence intervals are examined with a normal approximation and a nonparametric bootstrap. The accuracy of the different confidence interval estimates was then tested by methods of simulation under different distributional assumptions. The half normal distribution variance estimator has the best probability coverage. Finally, we provide a table of lower confidence intervals for Rosenthal's estimator.
Publication Bias in Meta-Analysis: Confidence Intervals for Rosenthal's Fail-Safe Number
Fragkos, Konstantinos C.; Tsagris, Michail; Frangos, Christos C.
2014-01-01
The purpose of the present paper is to assess the efficacy of confidence intervals for Rosenthal's fail-safe number. Although Rosenthal's estimator is highly used by researchers, its statistical properties are largely unexplored. First of all, we developed statistical theory which allowed us to produce confidence intervals for Rosenthal's fail-safe number. This was produced by discerning whether the number of studies analysed in a meta-analysis is fixed or random. Each case produces different variance estimators. For a given number of studies and a given distribution, we provided five variance estimators. Confidence intervals are examined with a normal approximation and a nonparametric bootstrap. The accuracy of the different confidence interval estimates was then tested by methods of simulation under different distributional assumptions. The half normal distribution variance estimator has the best probability coverage. Finally, we provide a table of lower confidence intervals for Rosenthal's estimator. PMID:27437470
Filter assembly for metallic and intermetallic tube filters
Alvin, Mary Anne; Lippert, Thomas E.; Bruck, Gerald J.; Smeltzer, Eugene E.
2001-01-01
A filter assembly (60) for holding a filter element (28) within a hot gas cleanup system pressure vessel is provided, containing: a filter housing (62), said filter housing having a certain axial length and having a peripheral sidewall, said sidewall defining an interior chamber (66); a one piece, all metal, fail-safe/regenerator device (68) within the interior chamber (66) of the filter housing (62) and/or extending beyond the axial length of the filter housing, said device containing an outward extending radial flange (71) within the filter housing for seating an essential seal (70), the device also having heat transfer media (72) disposed inside and screens (80) for particulate removal; one compliant gasket (70) positioned next to and above the outward extending radial flange of the fail-safe/regenerator device; and a porous metallic corrosion resistant superalloy type filter element body welded at the bottom of the metal fail-safe/regenerator device.
Silva, Alessandro Jose Nunes da; Almeida, Ildeberto Muniz de; Vilela, Rodolfo Andrade de Gouveia; Mendes, Renata Wey Berti; Hurtado, Sandra Lorena Beltran
2018-05-10
The Brazilian electricity sector has recorded high work-related mortality rates that have been associated with outsourcing, used to cut costs. In order to decrease the power outage time for consumers, the industry adopted the automatic circuit recloser as the technical solution. The device has hazardous implications for maintenance workers. The aim of this study was to analyze the origins and consequences of work accidents in power systems with automatic circuit recloser, using the Accident Analysis and Prevention (AAP) model. The AAP model was used to investigate two work accidents, aimed to explore the events' organizational origins. Case 1 - when changing a deenergized secondary line, a worker received a shock from the energized primary cable (13.8kV). The system reclosed three times, causing severe injury to the worker (amputation of a lower limb). Case 2 - a fatal work accident occurred during installation of a new crosshead on a partially insulated energized line. The tip of a metal cross arm section strap touched the energized secondary line and electrocuted the maintenance operator. The circuit breaker component of the automatic circuit recloser failed. The analyses revealed how business management logic can participate in the root causes of work accidents through failures in maintenance management, outsourced workforce management, and especially safety management in systems with reclosers. Decisions to adopt automation to guarantee power distribution should not overlook the risks to workers in overhead power lines or fail to acknowledge the importance of ensuring safe conditions.
Shape Control of Solar Collectors Using Shape Memory Alloy Actuators
NASA Technical Reports Server (NTRS)
Lobitz, D. W.; Grossman, J. W.; Allen, J. J.; Rice, T. M.; Liang, C.; Davidson, F. M.
1996-01-01
Solar collectors that are focused on a central receiver are designed with a mechanism for defocusing the collector or disabling it by turning it out of the path of the sun's rays. This is required to avoid damaging the receiver during periods of inoperability. In either of these two cases a fail-safe operation is very desirable where during power outages the collector passively goes to its defocused or deactivated state. This paper is principally concerned with focusing and defocusing the collector in a fail-safe manner using shape memory alloy actuators. Shape memory alloys are well suited to this application in that once calibrated the actuators can be operated in an on/off mode using a minimal amount of electric power. Also, in contrast to other smart materials that were investigated for this application, shape memory alloys are capable of providing enough stroke at the appropriate force levels to focus the collector. Design and analysis details presented, along with comparisons to test data taken from an actual prototype, demonstrate that the collector can be repeatedly focused and defocused within accuracies required by typical solar energy systems. In this paper the design, analysis and testing of a solar collector which is deformed into its desired shape by shape memory alloy actuators is presented. Computations indicate collector shapes much closer to spherical and with smaller focal lengths can be achieved by moving the actuators inward to a radius of approximately 6 inches. This would require actuators with considerably more stroke and some alternate SMA actuators are currently under consideration. Whatever SMA actuator is finally chosen for this application, repeatability and fatigue tests will be required to investigate the long term performance of the actuator.
A hybrid electromagnetic shock absorber for active vehicle suspension systems
NASA Astrophysics Data System (ADS)
Ebrahimi, Babak; Bolandhemmat, Hamidreza; Behrad Khamesee, Mir; Golnaraghi, Farid
2011-02-01
The use of electromagnetic dampers (ED) in vehicle active suspension systems has drawn considerable attention in the past few years, attributed to the fact that active suspension systems have shown superior performance in improving ride comfort and road handling of terrain vehicles, compared with their passive and semi-active counterparts. Although demonstrating superb performance, active suspensions still have some shortcomings that must be overcome. They have high energy consumption, weight, and cost and are not fail-safe in case of a power breakdown. The novel hybrid ED, which is proposed in this paper, is a potential solution to the above-mentioned drawbacks of conventional active suspension systems. The proposed hybrid ED is designed to inherit the high-performance characteristics of an active ED with the reliability of a passive damper in a single package. The eddy current damping effect is utilised as a source of the passive damping. First, a prototype ED is designed and fabricated. The prototype ED is then utilised to experimentally establish the design requirements for a real-size active ED. This is accomplished by comparing its vibration isolation performance in a 1-DOF quarter-car test rig with that of a same-class semi-active damper. Then, after a real-size active ED is designed, the concept of hybrid damper is introduced to the damper design to address the drawbacks of the active ED. Finally, the finite-element method is used to accurately model and analyse the designed hybrid damper. It is demonstrated that by introducing the eddy current damping effect to the active part, a passive damping of approximately 1570 Ns/m is achieved. This amount of passive damping guarantees that the damper is fail-safe and reduces the power consumption more than 70%, compared with an active ED in an automotive active suspension system.
Autonomous Vehicle (AV) Safe Testing Regulations Arizona state agencies must support the testing fails, the vehicle must be brought to a complete stop or safe state. The Arizona Department of Public
Advanced flight control system study
NASA Technical Reports Server (NTRS)
Hartmann, G. L.; Wall, J. E., Jr.; Rang, E. R.; Lee, H. P.; Schulte, R. W.; Ng, W. K.
1982-01-01
A fly by wire flight control system architecture designed for high reliability includes spare sensor and computer elements to permit safe dispatch with failed elements, thereby reducing unscheduled maintenance. A methodology capable of demonstrating that the architecture does achieve the predicted performance characteristics consists of a hierarchy of activities ranging from analytical calculations of system reliability and formal methods of software verification to iron bird testing followed by flight evaluation. Interfacing this architecture to the Lockheed S-3A aircraft for flight test is discussed. This testbed vehicle can be expanded to support flight experiments in advanced aerodynamics, electromechanical actuators, secondary power systems, flight management, new displays, and air traffic control concepts.
NASA Astrophysics Data System (ADS)
Anderman, Menahem; Benczur-Urmossy, Gabor; Haschka, Friedrich
Test data on prismatic sealed Ni-Cd batteries utilizing fiber structured electrodes (sealed FNC) is discussed. It is shown that, under a voltage limited charging scheme, the charge acceptance of the sealed FNC battery is far superior to that of the standard vented aircraft Ni-Cd batteries. This results in the sealed FNC battery maintaining its capacity over several thousand cycles without any need for electrical conditioning or water topping. APU start data demonstrate superior power capabilities over existing technologies. Performance at low temperature is presented. Abuse test results reveal a safe fail mechanism even under severe electrical abuse.
ARE660 Wind Generator: Low Wind Speed Technology for Small Turbine Development
DOE Office of Scientific and Technical Information (OSTI.GOV)
Robert W. Preus; DOE Project Officer - Keith Bennett
2008-04-23
This project is for the design of a wind turbine that can generate most or all of the net energy required for homes and small businesses in moderately windy areas. The purpose is to expand the current market for residential wind generators by providing cost effective power in a lower wind regime than current technology has made available, as well as reduce noise and improve reliability and safety. Robert W. Preus’ experience designing and/or maintaining residential wind generators of many configurations helped identify the need for an improved experience of safety for the consumer. Current small wind products have unreliablemore » or no method of stopping the wind generator in fault or high wind conditions. Consumers and their neighbors do not want to hear their wind generators. In addition, with current technology, only sites with unusually high wind speeds provide payback times that are acceptable for the on-grid user. Abundant Renewable Energy’s (ARE) basic original concept for the ARE660 was a combination of a stall controlled variable speed small wind generator and automatic fail safe furling for shutdown. The stall control for a small wind generator is not novel, but has not been developed for a variable speed application with a permanent magnet alternator (PMA). The fail safe furling approach for shutdown has not been used to our knowledge.« less
Investigation of structural factors of safety for the space shuttle
NASA Technical Reports Server (NTRS)
1972-01-01
A study was made of the factors governing the structural design of the fully reusable space shuttle booster to establish a rational approach to select optimum structural factors of safety. The study included trade studies of structural factors of safety versus booster service life, weight, cost, and reliability. Similar trade studies can be made on other vehicles using the procedures developed. The major structural components of a selected baseline booster were studied in depth, each being examined to determine the fatigue life, safe-life, and fail-safe capabilities of the baseline design. Each component was further examined to determine its reliability and safety requirements, and the change of structural weight with factors of safety. The apparent factors of safety resulting from fatigue, safe-life, proof test, and fail-safe requirements were identified. The feasibility of reduced factors of safety for design loads such as engine thrust, which are well defined, was examined.
Critical issues in assuring long lifetime and fail-safe operation of optical communications network
NASA Astrophysics Data System (ADS)
Paul, Dilip K.
1993-09-01
Major factors in assuring long lifetime and fail-safe operation in optical communications networks are reviewed in this paper. Reliable functionality to design specifications, complexity of implementation, and cost are the most critical issues. As economics is the driving force to set the goals as well as priorities for the design, development, safe operation, and maintenance schedules of reliable networks, a balance is sought between the degree of reliability enhancement, cost, and acceptable outage of services. Protecting both the link and the network with high reliability components, hardware duplication, and diversity routing can ensure the best network availability. Case examples include both fiber optic and lasercom systems. Also, the state-of-the-art reliability of photonics in space environment is presented.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hagen, E.W.
This report reviews and evaluates the performance of the compressed-air and pressurized-nitrogen gas systems in commercial nuclear power units. The information was collected from readily available operating experiences, licensee event reports, system designs in safety analysis reports, and regulatory documents. The results are collated and analyzed for significance and impact on power plant safety performance. Under certain circumstances, the fail-safe philosophy for a piece of equipment or subsystem of the compressed-air systems initiated a series of actions culminating in reactor transient or unit scram. However, based on this study of prevailing operating experiences, reclassifying the compressed-gas systems to a highermore » safety level will neither prevent (nor mitigate) the reoccurrences of such happenings nor alleviate nuclear power plant problems caused by inadequate maintenance, operating procedures, and/or practices. Conversely, because most of the problems were derived from the sources listed previously, upgrading of both maintenance and operating procedures will not only result in substantial improvement in the performance and availability of the compressed-air (and backup nitrogen) systems but in improved overall plant performance.« less
Bae, Ki Hyun; Tan, Susi; Yamashita, Atsushi; Ang, Wei Xia; Gao, Shu Jun; Wang, Shu; Chung, Joo Eun; Kurisawa, Motoichi
2017-12-01
The green tea catechin, (-)-epigallocatechin-3-O-gallate (EGCG), has gained significant attention as a potent adjuvant to enhance the antitumor efficacy of cisplatin while mitigating its harmful side effects. Herein we report the development of a fail-safe cisplatin nanomedicine constructed with hyaluronic acid-EGCG conjugate for ovarian cancer therapy. A simple mixing of this conjugate and cisplatin induces spontaneous self-assembly of micellar nanocomplexes having a spherical core-shell structure. The surface-exposed hyaluronic acid enables efficient delivery of cisplatin into CD44-overexpressing cancer cells via receptor-mediated endocytosis whereas the internally packed EGCG moieties offer an environment favorable for the encapsulation of cisplatin. In addition, the antioxidant effect of EGCG moieties ensures fail-safe protection against off-target organ toxicity originating from cisplatin-evoked oxidative stress. Pharmacokinetic and biodistribution studies reveal the prolonged blood circulation and preferential tumor accumulation of intravenously administered nanocomplexes. Moreover, the nanocomplexes exhibit superior antitumor efficacy over free cisplatin while displaying no toxicity in both a subcutaneous xenograft model and peritoneal metastatic model of human ovarian cancer. Our findings demonstrate proof of concept for the feasibility of green tea catechin-based micellar nanocomplexes as a safe and effective cisplatin nanomedicine for ovarian cancer treatment. Copyright © 2017 Elsevier Ltd. All rights reserved.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-05
... Commission Act for including a dolphin-safe label on tuna product in the United States that fails to meet the.... 130221153-3153-01] RIN 0648-BC78 Enhanced Document Requirements To Support Use of the Dolphin Safe Label on Tuna Products AGENCY: National Marine Fisheries Service (NMFS), National Oceanic and Atmospheric...
Recent Developments: PKI Square Dish for the Soleras Project
NASA Technical Reports Server (NTRS)
Rogers, W. E.
1984-01-01
The Square Dish solar collectors are subjected to rigorous design attention regarding corrosion at the site, and certification of the collector structure. The microprocessor controls and tracking mechanisms are improved in the areas of fail safe operations, durability, and low parasitic power requirements. Prototype testing demonstrates performance efficiency of approximately 72% at 730 F outlet temperature. Studies are conducted that include developing formal engineering design studies, developing formal engineering design drawing and fabrication details, establishing subcontracts for fabrication of major components, and developing a rigorous quality control system. The improved design is more cost effective to product and the extensive manuals developed for assembly and operation/maintenance result in faster field assembly and ease of operation.
Recent developments: PKI square dish for the Soleras Project
NASA Astrophysics Data System (ADS)
Rogers, W. E.
1984-03-01
The Square Dish solar collectors are subjected to rigorous design attention regarding corrosion at the site, and certification of the collector structure. The microprocessor controls and tracking mechanisms are improved in the areas of fail safe operations, durability, and low parasitic power requirements. Prototype testing demonstrates performance efficiency of approximately 72% at 730 F outlet temperature. Studies are conducted that include developing formal engineering design studies, developing formal engineering design drawing and fabrication details, establishing subcontracts for fabrication of major components, and developing a rigorous quality control system. The improved design is more cost effective to product and the extensive manuals developed for assembly and operation/maintenance result in faster field assembly and ease of operation.
Respiratory transfer value has fail-safe feature
NASA Technical Reports Server (NTRS)
Puccinelli, A. A.; Smith, J. R., Jr.
1965-01-01
Quick-acting, remote controlled valve connects either one of two oxygen or air supplies to a breathing tube. The valve, which is fall-safe, incorporates a cammed piston arrangement that is driven by a remote controlled reversible rotary solenoid or reversible electric motor.
Improved Quick Disconnect (QD) Interface Through Fail Safe Parts Identification
NASA Technical Reports Server (NTRS)
Blanch-Payne, Evelyn
2001-01-01
An extensive review of existing Quick Disconnects (QDs) mating and demating operations was performed to determine which shuttle part interface identifications and procedures contribute to human factor errors. The research methods used consisted of interviews with engineers and technicians, examination of incident reports, critiques of video and audio tapes of QD operations, and attendance of a Hyper QD operational course. The data strongly suggests that there are inherit human factor errors involved in QD operations. To promote fail-safe operations, QD interface problem areas and recommendations were outlined and reviewed. It is suggested that dialogue, investigations and recommendations continue.
Fail-safe storage rack for irradiated fuel rod assemblies
Lewis, D.R.
1993-03-23
A fail-safe storage rack is provided for interim storage of spent but radioactive nuclear fuel rod assemblies. The rack consists of a checkerboard array of substantially square, elongate receiving tubes fully enclosed by a double walled container, the outer wall of which is imperforate for liquid containment and the inner wall of which is provided with perforations for admitting moderator liquid flow to the elongate receiving tubes, the liquid serving to take up waste heat from the stored nuclear assemblies and dissipate same to the ambient liquid reservoir. A perforated cover sealing the rack facilitates cooling liquid entry and dissipation.
Fail-safe storage rack for irradiated fuel rod assemblies
Lewis, Donald R.
1993-01-01
A fail-safe storage rack is provided for interim storage of spent but radioactive nuclear fuel rod assemblies. The rack consists of a checkerboard array of substantially square, elongate receiving tubes fully enclosed by a double walled container, the outer wall of which is imperforate for liquid containment and the inner wall of which is provided with perforations for admitting moderator liquid flow to the elongate receiving tubes, the liquid serving to take up waste heat from the stored nuclear assemblies and dissipate same to the ambient liquid reservoir. A perforated cover sealing the rack facilitates cooling liquid entry and dissipation.
Fail-safe transcription termination: Because one is never enough.
Lemay, Jean-François; Bachand, François
2015-01-01
Termination of RNA polymerase II (RNAPII) transcription is a fundamental step of gene expression that involves the release of the nascent transcript and dissociation of RNAPII from the DNA template. As transcription termination is intimately linked to RNA 3' end processing, termination pathways have a key decisive influence on the fate of the transcribed RNA. Quite remarkably, when reaching the 3' end of genes, a substantial fraction of RNAPII fail to terminate transcription, requiring the contribution of alternative or "fail-safe" mechanisms of termination to release the polymerase. This point of view covers redundant mechanisms of transcription termination and how they relate to conventional termination models. In particular, we expand on recent findings that propose a reverse torpedo model of termination, in which the 3'5' exonucleolytic activity of the RNA exosome targets transcription events associated with paused and backtracked RNAPII.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-13
... slat actuator structural failure (rupture) and its adjacent actuator torque limiter failing high... outboard slat actuator structural failure (rupture) and its adjacent actuator torque limiter failing high... requirements.'' Under that section, Congress charges the FAA with promoting safe flight of civil aircraft in...
Modified hydraulic braking system limits angular deceleration to safe values
NASA Technical Reports Server (NTRS)
Briggs, R. S.; Council, M.; Green, P. M.
1966-01-01
Conventional spring actuated, hydraulically released, fail-safe disk braking system is modified to control the angular deceleration of a massive antenna. The hydraulic system provides an immediate preset pressure to the spring-loaded brake shoes and holds it at this value to decelerate the antenna at the desired rate.
Optimal Aircraft Control Upset Recovery With and Without Component Failures
NASA Technical Reports Server (NTRS)
Sparks, Dean W.; Moerder, Daniel D.
2002-01-01
This paper treats the problem of recovering sustainable nondescending (safe) flight in a transport aircraft after one or more of its control effectors fail. Such recovery can be a challenging goal for many transport aircraft currently in the operational fleet for two reasons. First, they have very little redundancy in their means of generating control forces and moments. These aircraft have, as primary control surfaces, a single rudder and pairwise elevators and aileron/spoiler units that provide yaw, pitch, and roll moments with sufficient bandwidth to be used in stabilizing and maneuvering the airframe. Beyond this, throttling the engines can provide additional moments, but on a much slower time scale. Other aerodynamic surfaces, such as leading and trailing edge flaps, are only intended to be placed in a position and left, and are, hence, very slow-moving. Because of this, loss of a primary control surface strongly degrades the controllability of the vehicle, particularly when the failed effector becomes stuck in a non-neutral position where it exerts a disturbance moment that must be countered by the remaining operating effectors. The second challenge in recovering safe flight is that these vehicles are not agile, nor can they tolerate large accelerations. This is of special importance when, at the outset of the recovery maneuver, the aircraft is flying toward the ground, as is frequently the case when there are major control hardware failures. Recovery of safe flight is examined in this paper in the context of trajectory optimization. For a particular transport aircraft, and a failure scenario inspired by an historical air disaster, recovery scenarios are calculated with and without control surface failures, to bring the aircraft to safe flight from the adverse flight condition that it had assumed, apparently as a result of contact with a vortex from a larger aircraft's wake. An effort has been made to represent relevant airframe dynamics, acceleration limits, and actuator limits faithfully, since these contribute to the lack of agility and control power that plays an important role in defining what can be achieved with the vehicle when it is in extremis.
30 CFR 18.44 - Non-intrinsically safe battery-powered equipment.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Non-intrinsically safe battery-powered... Construction and Design Requirements § 18.44 Non-intrinsically safe battery-powered equipment. (a) Battery-powered equipment shall use battery assemblies approved under Part 7 of this chapter, or battery...
30 CFR 18.44 - Non-intrinsically safe battery-powered equipment.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Non-intrinsically safe battery-powered... Construction and Design Requirements § 18.44 Non-intrinsically safe battery-powered equipment. (a) Battery-powered equipment shall use battery assemblies approved under Part 7 of this chapter, or battery...
30 CFR 18.44 - Non-intrinsically safe battery-powered equipment.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Non-intrinsically safe battery-powered... Construction and Design Requirements § 18.44 Non-intrinsically safe battery-powered equipment. (a) Battery-powered equipment shall use battery assemblies approved under Part 7 of this chapter, or battery...
30 CFR 18.44 - Non-intrinsically safe battery-powered equipment.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Non-intrinsically safe battery-powered... Construction and Design Requirements § 18.44 Non-intrinsically safe battery-powered equipment. (a) Battery-powered equipment shall use battery assemblies approved under Part 7 of this chapter, or battery...
30 CFR 18.44 - Non-intrinsically safe battery-powered equipment.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Non-intrinsically safe battery-powered... Construction and Design Requirements § 18.44 Non-intrinsically safe battery-powered equipment. (a) Battery-powered equipment shall use battery assemblies approved under Part 7 of this chapter, or battery...
Stabilization and reconstruction operations: the role of the US Army Veterinary Corps.
Smith, John C
2007-01-01
Stabilization and reconstruction operations in failed or failing states are vital to US security interests. These operations require a bottom-up approach, focusing on the population as the strategic center of gravity. This bottom-up approach must address the population's basic needs, as defined by Dr Abraham Maslow's hierarchy of needs, and provide a long-term means of self-sufficiency, rather than creating an "aid dependent economy." Focusing operations on agricultural projects provides relief from donor dependency, stimulates economic growth, and thwarts the power of spoilers. US Army Veterinary Corps personnel provide essential services ensuring the procurement of safe and wholesome subsistence and provision of medical care to government-owned animals. Veterinary Corps officers are also uniquely qualified to design and implement agricultural stabilization and reconstruction programs in conjunction with host-state ministries and agencies across the full range of military operations. Early, sustained engagement by veterinarians stimulates agricultural productivity, improves animal and human health, directly supports the population's hierarchy of needs on all levels, and accelerates stabilization operations by reducing the population's susceptibility to spoilers.
NASA Technical Reports Server (NTRS)
Khan, P.; Epp, L.
2006-01-01
Results of prototype hardware activities related to a 120-W, 32-GHz (Ka-band) solid-state power amplifier (SSPA) architecture study are presented. Spurious mode suppression and the power-handling capability of a prototype 24-way radial combiner and a prototype 2-way septum binary combiner were investigated. Experimental data indicate that a commercial absorptive filter, designed to pass the circular TE01 mode, effectively suppressed the higher-order modes generated by a narrowband, flower-petal-type mode transducer. However, the same filter was not effective in suppressing higher-order modes generated by the broadband Marie mode transducer that is used in the prototype waveguide radial combiner. Should greater filtering be required by a particular SSPA application, a broadband mode filter that can suppress specifically those higher-order modes that are generated by the Marie transducer will need to be developed. A back-to-back configuration of the prototype radial combiner was tested with drive power up to approximately 50 W. No anomalous behavior was observed. Power measurements of the septum combiner indicate that up to 10-W radio frequency (RF) can be dissipated in the integrated resistive element before a permanent performance shift is observed. Thus, a given adder (a single-stage, 2-way combiner) can safely combine two 20-W sources, and the adder will not be damaged in the event of a source failure. This result is used to calculate the maximum source power that can be safely combined as a function of the number of sources combined and the number of source failures allowed in a multi-stage combiner. The analysis shows that SSPA power >140 W can be generated by power combining 16 sources producing 10 W each. In this configuration, up to three sources could fail with the guarantee that the combiner would not be damaged. Finally, a modified prototype septum combiner design was verified. The improved design reduced the assembly time from over 2 hours to about 15 minutes per adder.
Is It safe? Nonoperative management of blunt splenic injuries in geriatric trauma patients.
Trust, Marc D; Teixeira, Pedro G; Brown, Lawrence H; Ali, Sadia; Coopwood, Ben; Aydelotte, Jayson D; Brown, Carlos V R
2018-01-01
Because of increased failure rates of nonoperative management (NOM) of blunt splenic injuries (BSI) in the geriatric population, dogma dictated that this management was unacceptable. Recently, there has been an increased use of this treatment strategy in the geriatric population. However, published data assessing the safety of NOM of BSI in this population is conflicting, and well-powered multicenter data are lacking. We performed a retrospective analysis of data from the National Trauma Data Bank (NTDB) from 2014 and identified young (age < 65) and geriatric (age ≥ 65) patients with a BSI. Patients who underwent splenectomy within 6 hours of admission were excluded from the analysis. Outcomes were failure of NOM and mortality. We identified 18,917 total patients with a BSI, 2,240 (12%) geriatric patients and 16,677 (88%) young patients. Geriatric patients failed NOM more often than younger patients (6% vs. 4%, p < 0.0001). On logistic regression analysis, Injury Severity Score of 16 or higher was the only independent risk factor associated with failure of NOM in geriatric patients (odds ratio, 2.778; confidence interval, 1.769-4.363; p < 0.0001). There was no difference in mortality in geriatric patients who had successful vs. failed NOM (11% vs. 15%; p = 0.22). Independent risk factors for mortality in geriatric patients included admission hypotension, Injury Severity Score of 16 or higher, Glasgow Coma Scale score of 8 or less, and cardiac disease. However, failure of NOM was not independently associated with mortality (odds ratio, 1.429; confidence interval, 0.776-2.625; p = 0.25). Compared with younger patients, geriatric patients had a higher but comparable rate of failed NOM of BSI, and failure rates are lower than previously reported. Failure of NOM in geriatric patients is not an independent risk factor for mortality. Based on our results, NOM of BSI in geriatric patients is safe. Therapeutic, level IV.
NASA Technical Reports Server (NTRS)
Westrup, R. W.
1972-01-01
Investigations of fatigue life, and safe-life and fail-safe design concepts as applied to space shuttle structure are summarized. The results are evaluated to select recommended structural design criteria to provide assurance that premature failure due to propagation of undetected crack-like defects will not occur during shuttle operational service. The space shuttle booster, GDC configuration B-9U, is selected as the reference vehicle. Structural elements used as basis of detail analyses include wing spar caps, vertical stabilizer skins, crew compartment skin, orbiter support frame, and propellant tank shell structure. Fatigue life analyses of structural elements are performed to define potential problem areas and establish upper limits of operating stresses. Flaw growth analyses are summarized in parametric form over a range of initial flaw types and sizes, operating stresses and service life requirements. Service life of 100 to 500 missions is considered.
75 FR 21528 - Airworthiness Directives; McDonnell Douglas Corporation Model MD-90-30 Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-26
... subsequently damage the hydraulic system and adversely affect the airplane's ability to make a safe landing... cylinder support fitting for the MLG failing during gear extension and subsequently damaging the hydraulic... the retract cylinder support fitting for the MLG, which could adversely affect the airplane's safe...
Setting the Clock for Fail-Safe Early Embryogenesis.
Fickentscher, Rolf; Struntz, Philipp; Weiss, Matthias
2016-10-28
The embryogenesis of the small nematode Caenorhabditis elegans is a remarkably robust self-organization phenomenon. Cell migration trajectories in the early embryo, for example, are well explained by mechanical cues that push cells into positions where they experience the least repulsive forces. Yet, how this mechanically guided progress in development is properly timed has remained elusive so far. Here, we show that cell volumes and division times are strongly anticorrelated during the early embryogenesis of C. elegans with significant differences between somatic cells and precursors of the germline. Our experimental findings are explained by a simple model that in conjunction with mechanical guidance can account for the fail-safe early embryogenesis of C. elegans.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pfister, A.; Goossen, C.; Coogler, K.
2012-07-01
Both the International Atomic Energy Agency (IAEA) and the U.S. Nuclear Regulatory Commission (NRC) require existing and new nuclear power plants to conduct plant assessments to demonstrate the unit's ability to withstand external hazards. The events that occurred at the Fukushima-Dai-ichi nuclear power station demonstrated the importance of designing a nuclear power plant with the ability to protect the plant against extreme external hazards. The innovative design of the AP1000{sup R} nuclear power plant provides unparalleled protection against catastrophic external events which can lead to extensive infrastructure damage and place the plant in an extended abnormal situation. The AP1000 plantmore » is an 1100-MWe pressurized water reactor with passive safety features and extensive plant simplifications that enhance construction, operation, maintenance and safety. The plant's compact safety related footprint and protection provided by its robust nuclear island structures prevent significant damage to systems, structures, and components required to safely shutdown the plant and maintain core and spent fuel pool cooling and containment integrity following extreme external events. The AP1000 nuclear power plant has been extensively analyzed and reviewed to demonstrate that it's nuclear island design and plant layout provide protection against both design basis and extreme beyond design basis external hazards such as extreme seismic events, external flooding that exceeds the maximum probable flood limit, and malicious aircraft impact. The AP1000 nuclear power plant uses fail safe passive features to mitigate design basis accidents. The passive safety systems are designed to function without safety-grade support systems (such as AC power, component cooling water, service water, compressed air or HVAC). The plant has been designed to protect systems, structures, and components critical to placing the reactor in a safe shutdown condition within the steel containment vessel which is further surrounded by a substantial 'steel concrete' composite shield building. The containment vessel is not affected by external flooding, and the shield building design provides hazard protection beyond that provided by a comparable reinforced concrete structure. The intent of this paper is to demonstrate the robustness of the AP1000 design against extreme events. The paper will focus on the plants ability to withstand extreme external events such as beyond design basis flooding, seismic events, and malicious aircraft impact. The paper will highlight the robustness of the AP1000 nuclear island design including the protection provided by the unique AP1000 composite shield building. (authors)« less
Compendium of fracture mechanics problems
NASA Technical Reports Server (NTRS)
Stallworth, R.; Wilson, C.; Meyers, C.
1990-01-01
Fracture mechanics analysis results are presented from the following structures/components analyzed at Marshall Space Flight Center (MSFC) between 1982 and 1989: space shuttle main engine (SSME), Hubble Space Telescope (HST), external tank attach ring, B-1 stand LOX inner tank, and solid rocket booster (SRB). Results from the SSME high pressure fuel turbopump (HPFTP) second stage blade parametric analysis determine a critical flaw size for a wide variety of stress intensity values. The engine 0212 failure analysis was a time dependent fracture life assessment. Results indicated that the disk ruptured due to an overspeed condition. Results also indicated that very small flaws in the curvic coupling area could propagate and lead to failure under normal operating conditions. It was strongly recommended that a nondestructive evaluation inspection schedule be implemented. The main ring of the HST, scheduled to launch in 1990, was analyzed by safe-life and fail-safe analyses. First safe-life inspection criteria curves for the ring inner and outer skins and the fore and aft channels were derived. Afterwards the skins and channels were determined to be fail-safe by analysis. A conservative safe-life analysis was done on the 270 redesign external tank attach ring. Results from the analysis were used to determine the nondestructive evaluation technique required.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-05
... Decree resolves alleged violations of the Clean Water Act and Safe Drinking Water Act at mobile home... provide drinking water at a number of its mobile home parks and illegally discharged sewage, failed to... environmental audits at each mobile home park, implementing corrective measures, conducting regular inspections...
The case for fire safe cigarettes made through industry documents
Gunja, M; Wayne, G; Landman, A; Connolly, G; McGuire, A
2002-01-01
Objectives: To examine the extensive research undertaken by the tobacco industry over the past 25 years toward development of a fire safe cigarette. Methods: Research was conducted through a web based search of internal tobacco industry documents made publicly available through the 1998 Master Settlement Agreement. Results: The documents reveal that the tobacco industry produced a fire safe cigarette years ago, but failed to put it on the market. These findings contradict public industry claims that denied the technical feasibility and commercial acceptability of fire safe cigarettes. Internal documents also reveal a decades long, coordinated political strategy used to block proposed legislation and obfuscate the fire safe issue. Conclusions: Federal legislation mandating fire safe cigarettes is needed. PMID:12432160
Worcester 1 Inch Solenoid Actuated Gas Operated SCHe System Valves
DOE Office of Scientific and Technical Information (OSTI.GOV)
MISKA, C.R.
1 inch gas-operated full-port ball valves incorporate a solenoid and limit switches as integral parts of the actuator. These valves are normally open and fail safe to the open position (GOV-1*02 and 1*06 fail closed) to provide a flow path of helium gas to the MCO under helium purge and off-normal conditions when the MCO is isolated.
Worcester 1 Inch Solenoid Actuated Gas Operated SCHe System Valves
DOE Office of Scientific and Technical Information (OSTI.GOV)
VAN KATWIJK, C.
1 inch Gas-operated full-port ball valves incorporate a solenoid and limit switches as integral parts of the actuator. These valves are normally open and fail safe to the open position (GOV-1*02 and 1*06 fail closed) to provide a flow path of helium gas to the MCO under helium purge and off-normal conditions when the MCO is isolated.
NASA Astrophysics Data System (ADS)
Blomquist, Richard S.
1995-05-01
On July 4,1997, the Mars Pathfinder spacecraft lands on Mars and starts conducting technological and scientific experiments. One experiment, the Alpha-Proton-X-ray Spectrometer, uses a sensor head placed against rocks and soil to determine their composition. To guarantee proper placement, a deployment mechanism mounted on the Mars Rover aligns the sensor head to within 20 deg of the rock and soil surfaces. In carrying out its task, the mechanism mimics the action of a human hand and arm. Consisting of a flexible wrist, a parallel link arm, a brush dc motor actuator, and a revolutionary non-pyrotechnic fail-safe release device, the mechanism correctly positions the sensor head on rocks as high as 0.29 m and on targets whose surfaces are tilted as much as 45 deg from the nominal orientation of the sensor head face. The mechanism weighs less than 0.5 kg, can withstand 100 g's, and requires less than 2.8 N x m of actuation torque. The fail-safe coupler utilizes Cerrobend, a metal alloy that melts at 60 C, to fuse the actuator and the rest of the mechanism together. A film heater wrapped around the coupler melts the metal, and Negator springs drive the mechanism into its stowed position. The fail-safe actuates using 6.75 Watts for 5 minutes in the event of an actuator failure.
NASA Technical Reports Server (NTRS)
Blomquist, Richard S.
1995-01-01
On July 4,1997, the Mars Pathfinder spacecraft lands on Mars and starts conducting technological and scientific experiments. One experiment, the Alpha-Proton-X-ray Spectrometer, uses a sensor head placed against rocks and soil to determine their composition. To guarantee proper placement, a deployment mechanism mounted on the Mars Rover aligns the sensor head to within 20 deg of the rock and soil surfaces. In carrying out its task, the mechanism mimics the action of a human hand and arm. Consisting of a flexible wrist, a parallel link arm, a brush dc motor actuator, and a revolutionary non-pyrotechnic fail-safe release device, the mechanism correctly positions the sensor head on rocks as high as 0.29 m and on targets whose surfaces are tilted as much as 45 deg from the nominal orientation of the sensor head face. The mechanism weighs less than 0.5 kg, can withstand 100 g's, and requires less than 2.8 N x m of actuation torque. The fail-safe coupler utilizes Cerrobend, a metal alloy that melts at 60 C, to fuse the actuator and the rest of the mechanism together. A film heater wrapped around the coupler melts the metal, and Negator springs drive the mechanism into its stowed position. The fail-safe actuates using 6.75 Watts for 5 minutes in the event of an actuator failure.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-25
... Secondary Power Distribution Assemblies (SPDAs) the message ``RECIRC SMK DET FAIL'' is displayed in the... the distribution of power and responsibilities among the various levels of government. For the reasons...] controller cards and both Secondary Power Distribution Assemblies (SPDAs) the message ``RECIRC SMK DET FAIL...
Synthetic activation of caspases: Artificial death switches
MacCorkle, Rebecca A.; Freeman, Kevin W.; Spencer, David M.
1998-01-01
The development of safe vectors for gene therapy requires fail-safe mechanisms to terminate therapy or remove genetically altered cells. The ideal “suicide switch” would be nonimmunogenic and nontoxic when uninduced and able to trigger cell death independent of tissue type or cell cycle stage. By using chemically induced dimerization, we have developed powerful death switches based on the cysteine proteases, caspase-1 ICE (interleukin-1β converting enzyme) and caspase-3 YAMA. In both cases, aggregation of the target protein is achieved by a nontoxic lipid-permeable dimeric FK506 analog that binds to the attached FK506-binding proteins, FKBPs. We find that intracellular cross-linking of caspase-1 or caspase-3 is sufficient to trigger rapid apoptosis in a Bcl-xL-independent manner, suggesting that these conditional proapoptotic molecules can bypass intracellular checkpoint genes, such as Bcl-xL, that limit apoptosis. Because these chimeric molecules are derived from autologous proteins, they should be nonimmunogenic and thus ideal for long-lived gene therapy vectors. These properties should also make chemically induced apoptosis useful for developmental studies, for treating hyperproliferative disorders, and for developing animal models to a wide variety of diseases. PMID:9520421
Soll, Christopher; Müller, Markus K; Wildi, Stefan; Clavien, Pierre-Alain; Weber, Markus
2008-01-01
Introduction Vertical-banded gastroplasty, a technique that is commonly performed in the treatment of morbid obesity, represents a nonadjustable restrictive procedure which reduces the volume of the upper stomach by a vertical stapler line. In addition, a textile or silicone band restricts food passage through the stomach. Case presentation A 71-year-old woman presented with a severe gastric stenosis 11 years after vertical gastroplasty. We describe a side-to-side gastrogastrostomy as a safe surgical procedure to restore the physiological gastric passage after failed vertical-banded gastroplasty. Conclusion Occasionally, restrictive procedures for morbid obesity cannot be converted into an alternative bariatric procedure to maintain weight control. This report demonstrates that a side-to-side gastrogastrostomy is a feasible and safe procedure. PMID:18513454
Pathology and failure in the design and implementation of adaptive management
Allen, Craig R.; Gunderson, Lance H.
2011-01-01
The conceptual underpinnings for adaptive management are simple; there will always be inherent uncertainty and unpredictability in the dynamics and behavior of complex ecological systems as a result non-linear interactions among components and emergence, yet management decisions must still be made. The strength of adaptive management is in the recognition and confrontation of such uncertainty. Rather than ignore uncertainty, or use it to preclude management actions, adaptive management can foster resilience and flexibility to cope with an uncertain future, and develop safe to fail management approaches that acknowledge inevitable changes and surprises. Since its initial introduction, adaptive management has been hailed as a solution to endless trial and error approaches to complex natural resource management challenges. However, its implementation has failed more often than not. It does not produce easy answers, and it is appropriate in only a subset of natural resource management problems. Clearly adaptive management has great potential when applied appropriately. Just as clearly adaptive management has seemingly failed to live up to its high expectations. Why? We outline nine pathologies and challenges that can lead to failure in adaptive management programs. We focus on general sources of failures in adaptive management, so that others can avoid these pitfalls in the future. Adaptive management can be a powerful and beneficial tool when applied correctly to appropriate management problems; the challenge is to keep the concept of adaptive management from being hijacked for inappropriate use.
van Woerkom, Arthur Ernst
2017-01-01
It is proposed that lithium’s therapeutic effects occur indirectly by augmenting a cascade of protective “fail-safe” pathways pre-configured to activate in response to a dangerous low cell [Mg++] situation, eg, posttraumatic brain injury, alongside relative cell adenosine triphosphate depletion. Lithium activates cell protection, as it neatly mimics a lowered intracellular [Mg++] level. PMID:28203080
The US space station and its electric power system
NASA Technical Reports Server (NTRS)
Thomas, Ronald L.
1988-01-01
The United States has embarked on a major development program to have a space station operating in low earth orbit by the mid-1990s. This endeavor draws on the talents of NASA and most of the aerospace firms in the U.S. Plans are being pursued to include the participation of Canada, Japan, and the European Space Agency in the space station. From the start of the program these was a focus on the utilization of the space station for science, technology, and commercial endeavors. These requirements were utilized in the design of the station and manifest themselves in: pressurized volume; crew time; power availability and level of power; external payload accommodations; microgravity levels; servicing facilities; and the ability to grow and evolve the space station to meet future needs. President Reagan directed NASA to develop a permanently manned space station in his 1984 State of the Union message. Since then the definition phase was completed and the development phase initiated. A major subsystem of the space station is its 75 kW electric power system. The electric power system has characteristics similar to those of terrestrial power systems. Routine maintenance and replacement of failed equipment must be accomplished safely and easily and in a minimum time while providing reliable power to users. Because of the very high value placed on crew time it is essential that the power system operate in an autonomous mode to minimize crew time required. The power system design must also easily accommodate growth as the power demands by users are expected to grow. An overview of the U.S. space station is provided with special emphasis on its electrical power system.
NASA Technical Reports Server (NTRS)
Thompson, G. A.
1970-01-01
System provides duplicate set of control logic circuitry. Comparators insure that the same data is present in both circuits. If any discrepancy is found, the machine is automatically stopped, before damage can occur.
Design and development of a structural mode control system
NASA Technical Reports Server (NTRS)
1977-01-01
A program was conducted to compile and document some of the existing information about the conceptual design, development, and tests of the B-1 structural mode control system (SMCS) and its impact on ride quality. This report covers the following topics: (1) Rationale of selection of SMCS to meet ride quality criteria versus basic aircraft stiffening. (2) Key considerations in designing an SMCS, including vane geometry, rate and deflection requirements, power required, compensation network design, and fail-safe requirements. (3) Summary of key results of SMCS vane wind tunnel tests. (4) SMCS performance. (5) SMCS design details, including materials, bearings, and actuators. (6) Results of qualification testing of SMCS on the "Iron Bird" flight control simulator, and lab qualification testing of the actuators. (7) Impact of SMCS vanes on engine inlet characteristics from wind tunnel tests.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-08
... proposed Consent Decree in United States of America v. American Municipal Power, Inc. (``AMP''), Civil..., a coal-fired power plant owned and operated by AMP in Marietta, Ohio. The alleged violations arise... the plant. The complaint alleges that AMP failed to obtain appropriate permits and failed to install...
Henderson, Theodore A; Morries, Larry D
2015-01-01
Traumatic brain injury (TBI) is a growing health concern affecting civilians and military personnel. Near-infrared (NIR) light has shown benefits in animal models and human trials for stroke and in animal models for TBI. Diodes emitting low-level NIR often have lacked therapeutic efficacy, perhaps failing to deliver sufficient radiant energy to the necessary depth. In this case report, a patient with moderate TBI documented in anatomical magnetic resonance imaging (MRI) and perfusion single-photon emission computed tomography (SPECT) received 20 NIR treatments in the course of 2 mo using a high-power NIR laser. Symptoms were monitored by clinical examination and a novel patient diary system specifically designed for this patient population. Clinical application of these levels of infrared energy for this patient with TBI yielded highly favorable outcomes with decreased depression, anxiety, headache, and insomnia, whereas cognition and quality of life improved. Neurological function appeared to improve based on changes in the SPECT by quantitative analysis. NIR in the power range of 10-15 W at 810 and 980 nm can safely and effectively treat chronic symptoms of TBI.
9th Diesel Engine Emissions Reduction (DEER) Workshop 2003
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kukla, P; Wright, J; Harris, G
2003-08-24
The PowerTrap{trademark} is a non-exhaust temperature dependent system that cannot become blocked and features a controlled regeneration process independent of the vehicle's drive cycle. The system has a low direct-current power source requirement available in both 12-volt and 24-volt configurations. The system is fully programmable, fully automated and includes Euro IV requirements of operation verification. The system has gained European component-type approval and has been tested with both on- road and off-road diesel fuel up to 2000 parts per million. The device is fail-safe: in the event of a device malfunction, it cannot affect the engine's performance. Accumulated mileage testingmore » is in excess of 640,000 miles to date. Vehicles include London-type taxicabs (Euro 1 and 2), emergency service fire engines (Euro 1, 2, and 3), inner city buses, and light-duty locomotives. Independent test results by Shell Global Solutions have consistently demonstrated 85-99 percent reduction of ultrafines across the 7-35 nanometer size range using a scanning mobility particle sizer with both ultra-low sulfur diesel and off-road high-sulfur fuel.« less
AP1000{sup R} nuclear power plant safety overview for spent fuel cooling
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gorgemans, J.; Mulhollem, L.; Glavin, J.
2012-07-01
The AP1000{sup R} plant is an 1100-MWe class pressurized water reactor with passive safety features and extensive plant simplifications that enhance construction, operation, maintenance, safety and costs. The AP1000 design uses passive features to mitigate design basis accidents. The passive safety systems are designed to function without safety-grade support systems such as AC power, component cooling water, service water or HVAC. Furthermore, these passive features 'fail safe' during a non-LOCA event such that DC power and instrumentation are not required. The AP1000 also has simple, active, defense-in-depth systems to support normal plant operations. These active systems provide the first levelmore » of defense against more probable events and they provide investment protection, reduce the demands on the passive features and support the probabilistic risk assessment. The AP1000 passive safety approach allows the plant to achieve and maintain safe shutdown in case of an accident for 72 hours without operator action, meeting the expectations provided in the U.S. Utility Requirement Document and the European Utility Requirements for passive plants. Limited operator actions are required to maintain safe conditions in the spent fuel pool via passive means. In line with the AP1000 approach to safety described above, the AP1000 plant design features multiple, diverse lines of defense to ensure spent fuel cooling can be maintained for design-basis events and beyond design-basis accidents. During normal and abnormal conditions, defense-in-depth and other systems provide highly reliable spent fuel pool cooling. They rely on off-site AC power or the on-site standby diesel generators. For unlikely design basis events with an extended loss of AC power (i.e., station blackout) or loss of heat sink or both, spent fuel cooling can still be provided indefinitely: - Passive systems, requiring minimal or no operator actions, are sufficient for at least 72 hours under all possible pool heat load conditions. - After 3 days, several different means are provided to continue spent fuel cooling using installed plant equipment as well as off-site equipment with built-in connections. Even for beyond design basis accidents with postulated pool damage and multiple failures in the passive safety-related systems and in the defense-in-depth active systems, the AP1000 multiple spent fuel pool spray and fill systems provide additional lines of defense to prevent spent fuel damage. (authors)« less
Improving U.S. Army Civil Affairs Assessment: A Consideration of Social Power
2017-12-01
Civil Affairs doctrine fails to take into account the workings of social power , and thus it limits the Army’s complete understanding of an... fail to take into account the workings of social power and thus limit under- standing of the operational environment. Social theorists agree that a...transform the structure of power in society , which in turn influences the nature of political, economic, social, and cultural systems. This view takes
Scalable and fail-safe deployment of the ATLAS Distributed Data Management system Rucio
NASA Astrophysics Data System (ADS)
Lassnig, M.; Vigne, R.; Beermann, T.; Barisits, M.; Garonne, V.; Serfon, C.
2015-12-01
This contribution details the deployment of Rucio, the ATLAS Distributed Data Management system. The main complication is that Rucio interacts with a wide variety of external services, and connects globally distributed data centres under different technological and administrative control, at an unprecedented data volume. It is therefore not possible to create a duplicate instance of Rucio for testing or integration. Every software upgrade or configuration change is thus potentially disruptive and requires fail-safe software and automatic error recovery. Rucio uses a three-layer scaling and mitigation strategy based on quasi-realtime monitoring. This strategy mainly employs independent stateless services, automatic failover, and service migration. The technologies used for deployment and mitigation include OpenStack, Puppet, Graphite, HAProxy and Apache. In this contribution, the interplay between these components, their deployment, software mitigation, and the monitoring strategy are discussed.
Time-saving and fail-safe dissection method for vestibulocochlear organs in gross anatomy classes.
Suzuki, Ryoji; Konno, Naoaki; Ishizawa, Akimitsu; Kanatsu, Yoshinori; Funakoshi, Kodai; Akashi, Hideo; Zhou, Ming; Abe, Hiroshi
2017-09-01
Because the vestibulocochlear organs are tiny and complex, and are covered by the petrous part of the temporal bone, they are very difficult for medical students to dissect and visualize during gross anatomy classes. Here, we report a time-saving and fail-safe procedure we have devised, using a hand-held hobby router. Nine en bloc temporal bone samples from donated human cadavers were used as trial materials for devising an appropriate procedure for dissecting the vestibulocochlear organs. A hand-held hobby router was used to cut through the temporal bone. After trials, the most time-saving and fail-safe method was selected. The performance of the selected method was assessed by a survey of 242 sides of 121 cadavers during gross anatomy classes for vestibulocochlear dissection. The assessment was based on the observation ratio. The best procedure appeared to be removal of the external acoustic meatus roof and tympanic cavity roof together with removal of the internal acoustic meatus roof. The whole procedure was completed within two dissection classes, each lasting 4.5 hr. The ratio of surveillance for the chorda tympani and three semicircular canals by students was significantly improved during 2013 through 2016. In our dissection class, "removal of the external acoustic meatus roof and tympanic cavity roof together with removal of the internal acoustic meatus roof" was the best procedure for students in the limited time available. Clin. Anat. 30:703-710, 2017. © 2017Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
78 FR 57146 - Combined Notice of Filings #1
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-17
...-1258-003. Applicants: Wabash Valley Power Association, Inc., Wabash Valley Energy Marketing, Inc. Description: Notice of Non Material Change in Status of Wabash Valley Power Association, Inc., et al. Filed...-015. Applicants: Safe Harbor Water Power Corporation. Description: Notice of Change in Status of Safe...
Laser beamed power - Satellite demonstration applications
NASA Technical Reports Server (NTRS)
Landis, Geoffrey A.; Westerlund, Larry H.
1992-01-01
Feasibility of using a ground-based laser to beam light to the solar arrays of orbiting satellites to a level sufficient to provide the operating power required is discussed. An example case of a GEO communications satellite near the end of life due to radiation damage of the solar arrays or battery failure is considered. It is concluded that the commercial satellite industry should be able to reap significant economic benefits through the use of power beaming which is capable of providing supplemental power for satellites with failing arrays, or primary power for failed batteries.
Impact of a major hurricane on surgical services in a university hospital.
Norcross, E D; Elliott, B M; Adams, D B; Crawford, F A
1993-01-01
Hurricane Hugo struck Charleston, South Carolina, on September 21, 1989. This report analyzes the impact this storm had upon surgical care at a university medical center. Although disaster planning began on September 17, hurricane damage by high winds and an 8.7-foot tidal surge led to loss of emergency power and water. Consequently, system failures occurred in air conditioning, vacuum suction, steam and ethylene oxide sterilization, plumbing, central paging, lighting, and refrigeration. The following surgical support services were affected. In the blood bank, lack of refrigeration meant no platelet packs for 2 days. In radiology, loss of electrical power damaged CT/MRI scanners and flooding ruined patient files, resulting in lost information. In the intensive care unit, loss of electricity meant no monitors and hand ventilation was used for 4 hours. In the operating room, lack of temperature and humidity control (steam, water, and suction supply) halted elective surgery until October 2. Ground and air transportation were limited by unsafe landing sites, impassable roads, and personnel exhaustion. Surgical planning for a major hurricane should include: 1) a fail-safe source of electrical power, 2) evacuation of as many critically ill patients as possible before the storm, 3) cancellation of all elective surgery, and 4) augmented ancillary service staffing with some, although limited, physician support.
Safe lithium-ion battery with ionic liquid-based electrolyte for hybrid electric vehicles
NASA Astrophysics Data System (ADS)
Damen, Libero; Lazzari, Mariachiara; Mastragostino, Marina
2011-10-01
A lithium-ion battery featuring graphite anode, LiFePO4-C cathode and an innovative, safe, ionic liquid-based electrolyte, was assembled and characterized in terms of specific energy and power after the USABC-DOE protocol for power-assist hybrid electric vehicle (HEV) application. The test results show that the battery surpasses the energy and power goals stated by USABC-DOE and, hence, this safe lithium-ion battery should be suitable for application in the evolving HEV market.
Extended Pulse-Powered Humidity-Freeze Cycling for Testing Module-Level Power Electronics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hacke, Peter L; Rodriguez, Miguel; Kempe, Michael D
An EMI suppression capacitor (polypropylene film type) failed by 'popcorning' due to vapor outgassing in pulse powered humidity-freeze cycles. No shorts or shunts could be detected despite mildly corroded metallization visible in the failed capacitor. Humidity-freeze cycling is optimized to break into moisture barriers. However, further studies will be required on additional module level power electronic (MLPE) devices to optimize the stress testing for condensation to precipitate any weakness to short circuiting and other humidity/bias failure modes.
Call sign intelligibility improvement using a spatial auditory display
NASA Technical Reports Server (NTRS)
Begault, Durand R.
1994-01-01
A spatial auditory display was designed for separating the multiple communication channels usually heard over one ear to different virtual auditory positions. The single 19 foot rack mount device utilizes digital filtering algorithms to separate up to four communication channels. The filters use four different binaural transfer functions, synthesized from actual outer ear measurements, to impose localization cues on the incoming sound. Hardware design features include 'fail-safe' operation in the case of power loss, and microphone/headset interfaces to the mobile launch communication system in use at KSC. An experiment designed to verify the intelligibility advantage of the display used 130 different call signs taken from the communications protocol used at NASA KSC. A 6 to 7 dB intelligibility advantage was found when multiple channels were spatially displayed, compared to monaural listening. The findings suggest that the use of a spatial auditory display could enhance both occupational and operational safety and efficiency of NASA operations.
Design, Qualification and Lessons Learned of the Shutter Calibration Mechanism for EnMAP Mission
NASA Astrophysics Data System (ADS)
Schmidt, Tilo; Muller, Silvio; Bergander, Arvid; Zajac, Kai; Seifart, Klaus
2015-09-01
The Shutter Calibration Mechanism (SCM) Assembly is one of three mechanisms which are developed by HTS for the EnMAP instrument in subcontract to OHB System AG Munich. EnMAP is the Environmental Mapping and Analysis Program of the German Space Agency DLR.The binary rotary encoder of the SCM using hall-effect sensors was already presented during ESMATS 2011. This paper summarizes the main functions and design features of the Hardware and focuses on qualification testing which has finished successfully in 2014. Of particular interest is the functional testing of the main drive including the precise hall-effect position sensing system and the test of the fail safe mechanism. In addition to standard test campaign required for QM also a shock emission measurement of the fail safe mechanism activation was conducted.Test conduction and results will be presented with focus on deviations from the expected behaviour, mitigation measures and on lessons learned.
CAT-tailing as a fail-safe mechanism for efficient degradation of stalled nascent polypeptides
Kostova, Kamena K.; Hickey, Kelsey L.; Osuna, Beatriz A.; Hussmann, Jeffrey A.; Frost, Adam; Weinberg, David E.; Weissman, Jonathan S.
2017-01-01
Ribosome stalling leads to recruitment of the Ribosome Quality control Complex (RQC), which targets the partially synthesized polypeptide for proteasomal degradation through the action of the ubiquitin ligase Ltn1p. A second core RQC component, Rqc2p, modifies the nascent polypeptide by adding a Carboxy-terminal Alanine and Threonine (CAT) tail through a non-canonical elongation reaction. Here we explore the role of CATtailing in nascent-chain degradation in budding yeast. We show that Ltn1p can efficiently access only nascent chain lysines immediately proximal to the ribosome exit tunnel. For substrates without Ltn1p-accessible lysines, CAT-tailing enables degradation by exposing lysines sequestered in the ribosome exit tunnel. Thus, CAT-tails do not serve as a degron, but rather provide a fail-safe mechanism that expands the range of RQC-degradable substrates. PMID:28751611
Treatments for traumatic brain injury with emphasis on transcranial near-infrared laser phototherapy
Morries, Larry D; Cassano, Paolo; Henderson, Theodore A
2015-01-01
Traumatic brain injury (TBI) is a growing health concern affecting civilians and military personnel. In this review, treatments for the chronic TBI patient are discussed, including pharmaceuticals, nutraceuticals, cognitive therapy, and hyperbaric oxygen therapy. All available literature suggests a marginal benefit with prolonged treatment courses. An emerging modality of treatment is near-infrared (NIR) light, which has benefit in animal models of stroke, spinal cord injury, optic nerve injury, and TBI, and in human trials for stroke and TBI. The extant literature is confounded by variable degrees of efficacy and a bewildering array of treatment parameters. Some data indicate that diodes emitting low-level NIR energy often have failed to demonstrate therapeutic efficacy, perhaps due to failing to deliver sufficient radiant energy to the necessary depth. As part of this review, we present a retrospective case series using high-power NIR laser phototherapy with a Class IV laser to treat TBI. We demonstrate greater clinical efficacy with higher fluence, in contrast to the bimodal model of efficacy previously proposed. In ten patients with chronic TBI (average time since injury 9.3 years) given ten treatments over the course of 2 months using a high-power NIR laser (13.2 W/0.89 cm2 at 810 nm or 9 W/0.89 cm2 at 810 nm and 980 nm), symptoms of headache, sleep disturbance, cognition, mood dysregulation, anxiety, and irritability improved. Symptoms were monitored by depression scales and a novel patient diary system specifically designed for this study. NIR light in the power range of 10–15 W at 810 nm and 980 nm can safely and effectively treat chronic symptoms of TBI. The clinical benefit and effects of infrared phototherapy on mitochondrial function and secondary molecular events are discussed in the context of adequate radiant energy penetration. PMID:26347062
Flight test and evaluation of Omega navigation for general aviation
NASA Technical Reports Server (NTRS)
Hwoschinsky, P. V.
1975-01-01
A seventy hour flight test program was performed to determine the suitability and accuracy of a low cost Omega navigation receiver in a general aviation aircraft. An analysis was made of signal availability in two widely separated geographic areas. Comparison is made of the results of these flights with other navigation systems. Conclusions drawn from the test experience indicate that developmental system improvement is necessary before a competent fail safe or fail soft area navigation system is offered to general aviation.
On the Safety of Machine Learning: Cyber-Physical Systems, Decision Sciences, and Data Products.
Varshney, Kush R; Alemzadeh, Homa
2017-09-01
Machine learning algorithms increasingly influence our decisions and interact with us in all parts of our daily lives. Therefore, just as we consider the safety of power plants, highways, and a variety of other engineered socio-technical systems, we must also take into account the safety of systems involving machine learning. Heretofore, the definition of safety has not been formalized in a machine learning context. In this article, we do so by defining machine learning safety in terms of risk, epistemic uncertainty, and the harm incurred by unwanted outcomes. We then use this definition to examine safety in all sorts of applications in cyber-physical systems, decision sciences, and data products. We find that the foundational principle of modern statistical machine learning, empirical risk minimization, is not always a sufficient objective. We discuss how four different categories of strategies for achieving safety in engineering, including inherently safe design, safety reserves, safe fail, and procedural safeguards can be mapped to a machine learning context. We then discuss example techniques that can be adopted in each category, such as considering interpretability and causality of predictive models, objective functions beyond expected prediction accuracy, human involvement for labeling difficult or rare examples, and user experience design of software and open data.
Automated Testing Experience of the Linear Aerospike SR-71 Experiment (LASRE) Controller
NASA Technical Reports Server (NTRS)
Larson, Richard R.
1999-01-01
System controllers must be fail-safe, low cost, flexible to software changes, able to output health and status words, and permit rapid retest qualification. The system controller designed and tested for the aerospike engine program was an attempt to meet these requirements. This paper describes (1) the aerospike controller design, (2) the automated simulation testing techniques, and (3) the real time monitoring data visualization structure. Controller cost was minimized by design of a single-string system that used an off-the-shelf 486 central processing unit (CPU). A linked-list architecture, with states (nodes) defined in a user-friendly state table, accomplished software changes to the controller. Proven to be fail-safe, this system reported the abort cause and automatically reverted to a safe condition for any first failure. A real time simulation and test system automated the software checkout and retest requirements. A program requirement to decode all abort causes in real time during all ground and flight tests assured the safety of flight decisions and the proper execution of mission rules. The design also included health and status words, and provided a real time analysis interpretation for all health and status data.
Sherrell, Dennis L.
1990-01-01
A hollow, collapsable seal member normally disposed in a natural expanded state offering fail-safe pressure sealing against a seating surface and adapted to be evacuated by a vacuum force for collapsing the seal member to disengage the same from said seating surface.
Sherrell, D.L.
1983-12-08
A hollow, collapsable seal member normally disposed in a natural expanded state offering fail-safe pressure sealing against a seating surface and adapted to be evacuated by a vacuum force for collapsing the seal member to disengage the same from said seating surface.
Curiosity's Autonomous Surface Safing Behavior Design
NASA Technical Reports Server (NTRS)
Neilson, Tracy A.; Manning, Robert M.
2013-01-01
The safing routines on all robotic deep-space vehicles are designed to put the vehicle in a power and thermally safe configuration, enabling communication with the mission operators on Earth. Achieving this goal is made a little more difficult on Curiosity because the power requirements for the core avionics and the telecommunication equipment exceed the capability of the single power source, the Multi-Mission Radioisotope Thermoelectric Generator. This drove the system design to create an operational mode, called "sleep mode", where the vehicle turns off most of the loads in order to charge the two Li-ion batteries. The system must keep the vehicle safe from over-heat and under-heat conditions, battery cell failures, under-voltage conditions, and clock failures, both while the computer is running and while the system is sleeping. The other goal of a safing routine is to communicate. On most spacecraft, this simply involves turning on the receiver and transmitter continuously. For Curiosity, Earth is above the horizon only a part of the day for direct communication to the Earth, and the orbiter overpass opportunities only occur a few times a day. The design must robustly place the Rover in a communicable condition at the correct time. This paper discusses Curiosity's autonomous safing behavior and describes how the vehicle remains power and thermally safe while sleeping, as well as a description of how the Rover communicates with the orbiters and Earth at specific times.
Cao, Yi; Yan, Weihui; Lu, Lina; Tao, Yijing; Lu, Wei; Chen, Yingwei; Tang, Qingya; Cai, Wei
2016-01-01
Congenital chylous ascites in the neonatal period is a rare entity. Total parenteral nutrition (TPN), medium chain triglyceride (MCT)-based diet, octreotide and repeated paracentesis are regarded as appropriate medical treatment for congenital chylous ascites, and surgery is recommended when conservative therapy has failed. We present two cases in which ascites were confirmed via an abdominal sonogram and diagnostic paracentesis. In our clinical experience, rice soup combined with PN can be a safe and effective intervention.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stinson-Bagby, Kelly L.; Fielder, Robert S.; Van Dyke, Melissa K.
2004-02-04
The motivation for the reported research was to support NASA space nuclear power initiatives through the development of advanced fiber optic sensors for space-based nuclear power applications. Distributed high temperature measurements were made with 20 FBG temperature sensors installed in the SAFE-100 thermal simulator at the NASA Marshal Space Flight Center. Experiments were performed at temperatures approaching 800 deg. C and 1150 deg. C for characterization studies of the SAFE-100 core. Temperature profiles were successfully generated for the core during temperature increases and decreases. Related tests in the SAFE-100 successfully provided strain measurement data.
The debate over food biotechnology in the United States: is a societal consensus achievable?
Groth, E
2001-07-01
Unless the public comes to agree that the benefits of food biotechnology are desirable and the associated risks are acceptable, our society may fail to realize much of the potential benefits. Three historical cases of major technological innovations whose benefits and risks were the subject of heated public controversy are examined, in search of lessons that may suggest a path toward consensus in the biotechnology debate. In each of the cases--water fluoridation, nuclear power and pesticides--proponents of the technology gathered scientific evidence that they believed established that the innovations were safe. In each case, the federal government was heavily involved in oversight, safety regulation, and in the first two cases, active promotion of the technology. Supporters of the technologies employed a variety of communications strategies, ranging from massive "educational" campaigns (e.g. "Our Friend The Atom") to vituperative ad hominem attacks on leading opponents. None of these strategies succeeded in achieving broad societal acceptance of the technologies. Fluoridation today is opposed as vigorously by activist groups as it was when first introduced around 1950; it has not been universally adopted even in the U.S., and it has been rejected in most other countries. The American nuclear power industry is moribund, and the public has essentially rejected the technology. The pesticide industry is thriving, with new generations of products succeeding older more hazardous chemicals in a constant cycle. However, strong regulation has failed to prevent adverse health and ecological effects, which have been empirically associated with pesticide uses after the chemicals were dispersed in the environment. Debate over whether risks of such effects are acceptable has been heated for four decades, with scientists and the public divided.
Songbird - AN Innovative Uas Combining the Advantages of Fixed Wing and Multi Rotor Uas
NASA Astrophysics Data System (ADS)
Thamm, F.-P.; Brieger, N.; Neitzke, K.-P.; Meyer, M.; Jansen, R.; Mönninghof, M.
2015-08-01
This paper describes a family of innovative fixed wing UAS with can vertical take off and land - the SONGBIRD family. With nominal payloads starting from 0.5 kg they can take off and land safely like a multi-rotor UAV, removing the need for an airstrip for the critical phases of operation. A specially designed flight controller allows stable flight at every point of the transition phase between VTOL and fixed wing mode. Because of this smooth process with a all time stable flight, very expensive payload like hyperspectral sensors or advanced optical cameras can be used. Due to their design all airplanes of the SONGBIRD family have excellent horizontal flight properties, a maximum speed of over 110 km/h, good gliding properties and long flight times of up to 1 h. Missions were flown in wind speeds up to 18 m/s. At every time of the flight it is possible to interrupt the mission and hover over a point of interest for detail investigations. The complete flight, including take-off and landing can be performed by autopilot. Designed for daily use in professional environments, SONGBIRDs are built out of glass-fibre and carbon composites for a long service life. For safe operations comprehensive security features are implemented, for example redundant flight controllers and sensors, advanced power management system and mature fail safe procedures. The aircraft can be dismantled into small parts for transportation. SONGBIRDS are available for different pay loads, from 500 g to 2 kg. The SONGBIRD family are interesting tools combining the advantages of multi-copter and fixed wing UAS.
Safe delivery of optical power from space.
Smith, M; Fork, R L; Cole, S
2001-05-07
More than a billion gigawatts of sunlight pass through the area extending from Earth out to geostationary orbit. A small fraction of this clean renewable power appears more than adequate to satisfy the projected needs of Earth, and of human exploration and development of space far into the future. Recent studies suggest safe and efficient access to this power can be achieved within 10 to 40 years. Light, enhanced in spatial and temporal coherence, as compared to natural sunlight, offers a means, and probably the only practical means, of usefully transmitting this power to Earth. We describe safety standards for satellite constellations and Earth based sites designed, respectively, to transmit, and receive this power. The spectral properties, number of satellites, and angle subtended at Earth that are required for safe delivery are identified and discussed.
Orr, Stanley G.
2000-01-01
A hardwired, fail-safe rack protection monitor utilizes electromechanical relays to respond to the detection by condition sensors of abnormal or alarm conditions (such as smoke, temperature, wind or water) that might adversely affect or damage equipment being protected. When the monitor is reset, the monitor is in a detection mode with first and second alarm relay coils energized. If one of the condition sensors detects an abnormal condition, the first alarm relay coil will be de-energized, but the second alarm relay coil will remain energized. This results in both a visual and an audible alarm being activated. If a second alarm condition is detected by another one of the condition sensors while the first condition sensor is still detecting the first alarm condition, both the first alarm relay coil and the second alarm relay coil will be de-energized. With both the first and second alarm relay coils de-energized, both a visual and an audible alarm will be activated. In addition, power to the protected equipment will be terminated and an alarm signal will be transmitted to an alarm central control. The monitor can be housed in a separate enclosure so as to provide an interface between a power supply for the protected equipment and the protected equipment.
Transmural heterogeneity of cellular level power output is reduced in human heart failure.
Haynes, Premi; Nava, Kristofer E; Lawson, Benjamin A; Chung, Charles S; Mitov, Mihail I; Campbell, Stuart G; Stromberg, Arnold J; Sadayappan, Sakthivel; Bonnell, Mark R; Hoopes, Charles W; Campbell, Kenneth S
2014-07-01
Heart failure is associated with pump dysfunction and remodeling but it is not yet known if the condition affects different transmural regions of the heart in the same way. We tested the hypotheses that the left ventricles of non-failing human hearts exhibit transmural heterogeneity of cellular level contractile properties, and that heart failure produces transmural region-specific changes in contractile function. Permeabilized samples were prepared from the sub-epicardial, mid-myocardial, and sub-endocardial regions of the left ventricular free wall of non-failing (n=6) and failing (n=10) human hearts. Power, an in vitro index of systolic function, was higher in non-failing mid-myocardial samples (0.59±0.06μWmg(-1)) than in samples from the sub-epicardium (p=0.021) and the sub-endocardium (p=0.015). Non-failing mid-myocardial samples also produced more isometric force (14.3±1.33kNm(-2)) than samples from the sub-epicardium (p=0.008) and the sub-endocardium (p=0.026). Heart failure reduced power (p=0.009) and force (p=0.042) but affected the mid-myocardium more than the other transmural regions. Fibrosis increased with heart failure (p=0.021) and mid-myocardial tissue from failing hearts contained more collagen than matched sub-epicardial (p<0.001) and sub-endocardial (p=0.043) samples. Power output was correlated with the relative content of actin and troponin I, and was also statistically linked to the relative content and phosphorylation of desmin and myosin light chain-1. Non-failing human hearts exhibit transmural heterogeneity of contractile properties. In failing organs, region-specific fibrosis produces the greatest contractile deficits in the mid-myocardium. Targeting fibrosis and sarcomeric proteins in the mid-myocardium may be particularly effective therapies for heart failure. Copyright © 2014 Elsevier Ltd. All rights reserved.
Mushambi, M C; Kinsella, S M; Popat, M; Swales, H; Ramaswamy, K K; Winton, A L; Quinn, A C
2015-11-01
The Obstetric Anaesthetists' Association and Difficult Airway Society have developed the first national obstetric guidelines for the safe management of difficult and failed tracheal intubation during general anaesthesia. They comprise four algorithms and two tables. A master algorithm provides an overview. Algorithm 1 gives a framework on how to optimise a safe general anaesthetic technique in the obstetric patient, and emphasises: planning and multidisciplinary communication; how to prevent the rapid oxygen desaturation seen in pregnant women by advocating nasal oxygenation and mask ventilation immediately after induction; limiting intubation attempts to two; and consideration of early release of cricoid pressure if difficulties are encountered. Algorithm 2 summarises the management after declaring failed tracheal intubation with clear decision points, and encourages early insertion of a (preferably second-generation) supraglottic airway device if appropriate. Algorithm 3 covers the management of the 'can't intubate, can't oxygenate' situation and emergency front-of-neck airway access, including the necessity for timely perimortem caesarean section if maternal oxygenation cannot be achieved. Table 1 gives a structure for assessing the individual factors relevant in the decision to awaken or proceed should intubation fail, which include: urgency related to maternal or fetal factors; seniority of the anaesthetist; obesity of the patient; surgical complexity; aspiration risk; potential difficulty with provision of alternative anaesthesia; and post-induction airway device and airway patency. This decision should be considered by the team in advance of performing a general anaesthetic to make a provisional plan should failed intubation occur. The table is also intended to be used as a teaching tool to facilitate discussion and learning regarding the complex nature of decision-making when faced with a failed intubation. Table 2 gives practical considerations of how to awaken or proceed with surgery. The background paper covers recommendations on drugs, new equipment, teaching and training. © 2015 The Authors. Anaesthesia published by John Wiley & Sons Ltd on behalf of Association of Anaesthetists of Great Britain and Ireland.
Mushambi, M C; Kinsella, S M; Popat, M; Swales, H; Ramaswamy, K K; Winton, A L; Quinn, A C
2015-01-01
The Obstetric Anaesthetists' Association and Difficult Airway Society have developed the first national obstetric guidelines for the safe management of difficult and failed tracheal intubation during general anaesthesia. They comprise four algorithms and two tables. A master algorithm provides an overview. Algorithm 1 gives a framework on how to optimise a safe general anaesthetic technique in the obstetric patient, and emphasises: planning and multidisciplinary communication; how to prevent the rapid oxygen desaturation seen in pregnant women by advocating nasal oxygenation and mask ventilation immediately after induction; limiting intubation attempts to two; and consideration of early release of cricoid pressure if difficulties are encountered. Algorithm 2 summarises the management after declaring failed tracheal intubation with clear decision points, and encourages early insertion of a (preferably second-generation) supraglottic airway device if appropriate. Algorithm 3 covers the management of the ‘can't intubate, can't oxygenate’ situation and emergency front-of-neck airway access, including the necessity for timely perimortem caesarean section if maternal oxygenation cannot be achieved. Table 1 gives a structure for assessing the individual factors relevant in the decision to awaken or proceed should intubation fail, which include: urgency related to maternal or fetal factors; seniority of the anaesthetist; obesity of the patient; surgical complexity; aspiration risk; potential difficulty with provision of alternative anaesthesia; and post-induction airway device and airway patency. This decision should be considered by the team in advance of performing a general anaesthetic to make a provisional plan should failed intubation occur. The table is also intended to be used as a teaching tool to facilitate discussion and learning regarding the complex nature of decision-making when faced with a failed intubation. Table 2 gives practical considerations of how to awaken or proceed with surgery. The background paper covers recommendations on drugs, new equipment, teaching and training. PMID:26449292
Inherently safe passive gas monitoring system
Cordaro, Joseph V.; Bellamy, John Stephen; Shuler, James M.; Shull, Davis J.; Leduc, Daniel R.
2016-09-06
Generally, the present disclosure is directed to gas monitoring systems that use inductive power transfer to safely power an electrically passive device included within a nuclear material storage container. In particular, the electrically passive device can include an inductive power receiver for receiving inductive power transfer through a wall of the nuclear material storage container. The power received by the inductive power receiver can be used to power one or more sensors included in the device. Thus, the device is not required to include active power generation components such as, for example, a battery, that increase the risk of a spark igniting flammable gases within the container.
OGLE-2014-SN-073 as a fallback accretion powered supernova
NASA Astrophysics Data System (ADS)
Moriya, Takashi J.; Terreran, Giacomo; Blinnikov, Sergei I.
2018-03-01
We investigate the possibility that the energetic Type II supernova OGLE-2014-SN-073 is powered by a fallback accretion following the failed explosion of a massive star. Taking massive hydrogen-rich supernova progenitor models, we estimate the fallback accretion rate and calculate the light-curve evolution of supernovae powered by the fallback accretion. We find that such fallback accretion powered models can reproduce the overall observational properties of OGLE-2014-SN-073. It may imply that some failed explosions could be observed as energetic supernovae like OGLE-2014-SN-073 instead of faint supernovae as previously proposed.
Identification, analysis, and remedial treatment of low guardrail in Virginia.
DOT National Transportation Integrated Search
1981-01-01
Guardrails that are too low may fail to safely redirect errant vehicles; instead, the vehicles may vault the guardrails, resulting in severe accidents. An analysis of data on a small sample of guardrails throughout-Virginia showed that over 80% of th...
77 FR 6122 - Providing Refurbishment Services to Federal Agencies
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-07
... equipment? 5. Describe the process for disposing and recycling of failed equipment. Have all facilities in your recycling and disposal process been certified to safely recycle and manage electronics? If so... firms offering refurbishment services, including those developed specifically for recycling facilities...
Keep Food and Water Safe After a Disaster or Power Outage
... DO NOT drink the water. Use a safe water supply like bottled or treated water. Contact your local, ... you know the water is safe, use bottled water or some other safe supply of water. If you suspect your water has ...
Prototype data terminal: Multiplexer/demultiplexer
NASA Technical Reports Server (NTRS)
Leck, D. E.; Goodwin, J. E.
1972-01-01
The design and operation of a quad redundant data terminal and a multiplexer/demultiplexer (MDU) design are described. The most unique feature is the design of the quad redundant data terminal. This is one of the few designs where the unit is fail/op, fail/op, fail/safe. Laboratory tests confirm that the unit will operate satisfactorily with the failure of three out of four channels. Although the design utilizes state-of-the-art technology. The waveform error checks, the voting techniques, and the parity bit checks are believed to be used in unique configurations. Correct word selection routines are also novel, if not unique. The MDU design, while not redundant, utilizes, the latest state-of-the-art advantages of light couplers and integrated circuit amplifiers.
Submerged passively-safe power plant
Herring, J. Stephen
1993-01-01
The invention as presented consists of a submerged passively-safe power station including a pressurized water reactor capable of generating at least 600 MW of electricity, encased in a double hull vessel, and provides fresh water by using the spent thermal energy in a multistage flash desalination process.
Guimaraes, Marcelo; Schonholz, Claudio; Hannegan, Christopher; Anderson, Michael Bret; Shi, June; Selby, Bayne
2012-08-01
To report the technique and acute technical results associated with the PowerWire Radiofrequency (RF) Guidewire used to recanalize central vein occlusions (CVOs) after the failure of conventional endovascular techniques. A retrospective study was conducted from January 2008 to December 2011, which identified all patients with CVOs who underwent treatment with a novel RF guide wire. Forty-two symptomatic patients (with swollen arm or superior vena cava [SVC] syndrome) underwent RF wire recanalization of 43 CVOs, which were then implanted with stents. The distribution of CVOs in central veins was as follows: six subclavian, 29 brachiocephalic, and eight SVC. All patients had a history of central venous catheter placement. Patients were monitored with regular clinical evaluations and central venography after treatment. All 42 patients had successful recanalization of CVOs facilitated by the RF wire technique. There was one complication, which was not directly related to the RF wire: one case of cardiac tamponade attributed to balloon angioplasty after stent placement. Forty of 42 patients (95.2%) had patent stents and were asymptomatic at 6 and 9 months after treatment. The present results suggest that the RF wire technique is a safe and efficient alternative in the recanalization of symptomatic and chronic CVOs when conventional endovascular techniques have failed. Copyright © 2012 SIR. Published by Elsevier Inc. All rights reserved.
Transportation-Related Safety Behaviors in Top-Grossing Children's Movies from 2008 to 2013.
Boppana, Shilpa; Shen, Jiabin; Schwebel, David C
2016-05-01
Children regularly imitate behavior from movies. The authors assessed injury risk behaviors in top-grossing children's films. The 5 top-grossing G- or PG-rated movies annually from 2008 to 2013 were included, including animated movies and those set in the past/future. Researchers coded transportation scenes for risk taking in 3 domains: protection/equipment, unsafe behaviors, and distraction/attention. Safe and risky behaviors were recorded across the 3 domains. With regard to protection and equipment, 20% of motor vehicle scenes showed characters riding without seat belts and 27% of scenes with motorcycles showed characters riding without helmets. Eighty-nine percent of scenes with horses showed riders without helmets and 67% of boat operators failed to wear personal flotation devices. The most common unsafe behaviors were speeding and unsafe street-crossing. Twenty-one percent of scenes with motor vehicles showed drivers speeding and 90% of pedestrians in films failed to wait for signal changes. Distracted and inattentive behaviors were rare, with distracted driving of motor vehicles occurring in only approximately 2% of total driving scenes. Although many safe transportation behaviors were portrayed, the film industry continues to depict unsafe behaviors in movies designed for pediatric audiences. There is a need for the film industry to continue to balance entertainment and art with modeling of safe behavior for children.
Fatigue analysis of composite materials using the fail-safe concept
NASA Technical Reports Server (NTRS)
Stievenard, G.
1982-01-01
If R1 is the probability of having a crack on a flight component and R2 is the probability of seeing this crack propagate between two scheduled inspections, the global failure regulation states that this product must not exceed 0.0000001.
Voter comparator switch provides fail safe data communications system - A concept
NASA Technical Reports Server (NTRS)
Koczela, L. J.; Wilgus, D. S.
1971-01-01
System indicates status of computers and controls operational modes. Two matrices are used - one relating to permissible system states, the other relating to requested system states. Concept is useful to designers of digital data transmission systems and time shared computer systems.
DOT National Transportation Integrated Search
1993-05-01
The Maglev control computer system should be designed to verifiably possess high reliability and safety as well as high availability to make Maglev a dependable and attractive transportation alternative to the public. A Maglev computer system has bee...
CAT-tailing as a fail-safe mechanism for efficient degradation of stalled nascent polypeptides.
Kostova, Kamena K; Hickey, Kelsey L; Osuna, Beatriz A; Hussmann, Jeffrey A; Frost, Adam; Weinberg, David E; Weissman, Jonathan S
2017-07-28
Ribosome stalling leads to recruitment of the ribosome quality control complex (RQC), which targets the partially synthesized polypeptide for proteasomal degradation through the action of the ubiquitin ligase Ltn1p. A second core RQC component, Rqc2p, modifies the nascent polypeptide by adding a carboxyl-terminal alanine and threonine (CAT) tail through a noncanonical elongation reaction. Here we examined the role of CAT-tailing in nascent-chain degradation in budding yeast. We found that Ltn1p efficiently accessed only nascent-chain lysines immediately proximal to the ribosome exit tunnel. For substrates without Ltn1p-accessible lysines, CAT-tailing enabled degradation by exposing lysines sequestered in the ribosome exit tunnel. Thus, CAT-tails do not serve as a degron, but rather provide a fail-safe mechanism that expands the range of RQC-degradable substrates. Copyright © 2017 The Authors, some rights reserved; exclusive licensee American Association for the Advancement of Science. No claim to original U.S. Government Works.
The fail-safe mechanism of post-transcriptional silencing of unspliced HAC1 mRNA.
Di Santo, Rachael; Aboulhouda, Soufiane; Weinberg, David E
2016-10-01
HAC1 encodes a transcription factor that is the central effector of the unfolded protein response (UPR) in budding yeast. When the UPR is inactive, HAC1 mRNA is stored as an unspliced isoform in the cytoplasm and no Hac1 protein is detectable. Intron removal is both necessary and sufficient to relieve the post-transcriptional silencing of HAC1 mRNA, yet the precise mechanism by which the intron prevents Hac1 protein accumulation has remained elusive. Here, we show that a combination of inhibited translation initiation and accelerated protein degradation-both dependent on the intron-prevents the accumulation of Hac1 protein when the UPR is inactive. Functionally, both components of this fail-safe silencing mechanism are required to prevent ectopic production of Hac1 protein and concomitant activation of the UPR. Our results provide a mechanistic understanding of HAC1 regulation and reveal a novel strategy for complete post-transcriptional silencing of a cytoplasmic mRNA.
Submerged passively-safe power plant
Herring, J.S.
1993-09-21
The invention as presented consists of a submerged passively-safe power station including a pressurized water reactor capable of generating at least 600 MW of electricity, encased in a double hull vessel, and provides fresh water by using the spent thermal energy in a multistage flash desalination process. 8 figures.
The optimal power puzzle: scrutiny of the monotone likelihood ratio assumption in multiple testing.
Cao, Hongyuan; Sun, Wenguang; Kosorok, Michael R
2013-01-01
In single hypothesis testing, power is a non-decreasing function of type I error rate; hence it is desirable to test at the nominal level exactly to achieve optimal power. The puzzle lies in the fact that for multiple testing, under the false discovery rate paradigm, such a monotonic relationship may not hold. In particular, exact false discovery rate control may lead to a less powerful testing procedure if a test statistic fails to fulfil the monotone likelihood ratio condition. In this article, we identify different scenarios wherein the condition fails and give caveats for conducting multiple testing in practical settings.
Transient Approximation of SAFE-100 Heat Pipe Operation
NASA Technical Reports Server (NTRS)
Bragg-Sitton, Shannon M.; Reid, Robert S.
2005-01-01
Engineers at Los Alamos National Laboratory (LANL) have designed several heat pipe cooled reactor concepts, ranging in power from 15 kWt to 800 kWt, for both surface power systems and nuclear electric propulsion systems. The Safe, Affordable Fission Engine (SAFE) is now being developed in a collaborative effort between LANL and NASA Marshall Space Flight Center (NASA/MSFC). NASA is responsible for fabrication and testing of non-nuclear, electrically heated modules in the Early Flight Fission Test Facility (EFF-TF) at MSFC. In-core heat pipes must be properly thawed as the reactor power starts. Computational models have been developed to assess the expected operation of a specific heat pipe design during start-up, steady state operation, and shutdown. While computationally intensive codes provide complete, detailed analyses of heat pipe thaw, a relatively simple. concise routine can also be applied to approximate the response of a heat pipe to changes in the evaporator heat transfer rate during start-up and power transients (e.g., modification of reactor power level) with reasonably accurate results. This paper describes a simplified model of heat pipe start-up that extends previous work and compares the results to experimental measurements for a SAFE-100 type heat pipe design.
Description and comparative evaluation of a proposed design for the low visibility approach study
DOT National Transportation Integrated Search
1985-10-01
Ths memorandum was prepared in support of the low visibility simulation study being : conducted by the FAA as a basis for establishing the lowest RVR (runway visual range) : required for safe, fail passive auto landings in Category III weather. A des...
78 FR 57542 - Airworthiness Directives; The Boeing Company Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-19
... cracked retract actuator fuse pins that could fail earlier than the previously determined safe life limit... 5 p.m., Monday through Friday, except Federal holidays. For service information identified in this proposed AD, contact Boeing Commercial Airplanes, Attention: Data & Services Management, P.O. Box 3707, MC...
46 CFR 28.880 - Hydraulic equipment.
Code of Federal Regulations, 2011 CFR
2011-10-01
... times the system's maximum operating pressure. (c) Each hydraulic system must be equipped with at least... sudden loss of control due to loss of hydraulic system pressure. A system is considered to be fail-safe... catalog number and maximum allowable working pressure. (k) Existing hydraulic piping, nonmetallic hose...
46 CFR 28.880 - Hydraulic equipment.
Code of Federal Regulations, 2013 CFR
2013-10-01
... times the system's maximum operating pressure. (c) Each hydraulic system must be equipped with at least... sudden loss of control due to loss of hydraulic system pressure. A system is considered to be fail-safe... catalog number and maximum allowable working pressure. (k) Existing hydraulic piping, nonmetallic hose...
46 CFR 28.880 - Hydraulic equipment.
Code of Federal Regulations, 2014 CFR
2014-10-01
... times the system's maximum operating pressure. (c) Each hydraulic system must be equipped with at least... sudden loss of control due to loss of hydraulic system pressure. A system is considered to be fail-safe... catalog number and maximum allowable working pressure. (k) Existing hydraulic piping, nonmetallic hose...
46 CFR 28.880 - Hydraulic equipment.
Code of Federal Regulations, 2012 CFR
2012-10-01
... times the system's maximum operating pressure. (c) Each hydraulic system must be equipped with at least... sudden loss of control due to loss of hydraulic system pressure. A system is considered to be fail-safe... catalog number and maximum allowable working pressure. (k) Existing hydraulic piping, nonmetallic hose...
Analog front-end design of the STS/MUCH-XYTER2—full size prototype ASIC for the CBM experiment
NASA Astrophysics Data System (ADS)
Kleczek, Rafal
2017-01-01
The design of the analog front-end of the STS/MUCH-XYTER2 ASIC, a full-size prototype chip for the Silicon Tracking System (STS, based on double-sided silicon strip sensors) and Muon Chamber (MUCH, based on gas sensors) detectors is presented. The ASIC contains 128 charge processing channels, each built of a charge sensitive amplifier, a polarity selection circuit and two pulse shaping amplifiers forming two parallel signal paths. The first path is used for timing measurement with a fast discriminator. The second path allows low-noise amplitude measurement with a 5-bit continuous-time flash ADC. Different operating conditions and constraints posed by two target detectors' applications require front-end electronics flexibility to meet extended system-wise requirements. The presented circuit implements switchable shaper peaking time, gain switching and trimming, input amplifier pulsed reset circuit, fail-safe measures. The power consumption is scalable (for the STS and the MUCH modes), but limited to 10 mW/channel.
Robust nonlinear system identification: Bayesian mixture of experts using the t-distribution
NASA Astrophysics Data System (ADS)
Baldacchino, Tara; Worden, Keith; Rowson, Jennifer
2017-02-01
A novel variational Bayesian mixture of experts model for robust regression of bifurcating and piece-wise continuous processes is introduced. The mixture of experts model is a powerful model which probabilistically splits the input space allowing different models to operate in the separate regions. However, current methods have no fail-safe against outliers. In this paper, a robust mixture of experts model is proposed which consists of Student-t mixture models at the gates and Student-t distributed experts, trained via Bayesian inference. The Student-t distribution has heavier tails than the Gaussian distribution, and so it is more robust to outliers, noise and non-normality in the data. Using both simulated data and real data obtained from the Z24 bridge this robust mixture of experts performs better than its Gaussian counterpart when outliers are present. In particular, it provides robustness to outliers in two forms: unbiased parameter regression models, and robustness to overfitting/complex models.
Main propulsion system design recommendations for an advanced Orbit Transfer Vehicle
NASA Technical Reports Server (NTRS)
Redd, L.
1985-01-01
Various main propulsion system configurations of an advanced OTV are evaluated with respect to the probability of nonindependent failures, i.e., engine failures that disable the entire main propulsion system. Analysis of the life-cycle cost (LCC) indicates that LCC is sensitive to the main propulsion system reliability, vehicle dry weight, and propellant cost; it is relatively insensitive to the number of missions/overhaul, failures per mission, and EVA and IVA cost. In conclusion, two or three engines are recommended in view of their highest reliability, minimum life-cycle cost, and fail operational/fail safe capability.
75 FR 50878 - Airworthiness Directives; McDonnell Douglas Corporation Model MD-90-30 Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-18
... support fitting for the MLG failing during gear extension and subsequently damaging the hydraulic system... retract cylinder support fitting for the MLG, which could adversely affect the airplane's safe landing... service information identified in this AD, contact Boeing Commercial Airplanes, Attention: Data & Services...
14 CFR 23.775 - Windshields and windows.
Code of Federal Regulations, 2011 CFR
2011-01-01
... loadings and flight loads, or compliance with the fail-safe requirements of paragraph (d) of this section... loads combined with critical aerodynamic pressure and temperature effects, after failure of any load... in front of the pilots must be arranged so that, assuming the loss of vision through any one panel...
14 CFR 23.775 - Windshields and windows.
Code of Federal Regulations, 2010 CFR
2010-01-01
... loadings and flight loads, or compliance with the fail-safe requirements of paragraph (d) of this section... loads combined with critical aerodynamic pressure and temperature effects, after failure of any load... in front of the pilots must be arranged so that, assuming the loss of vision through any one panel...
14 CFR 23.775 - Windshields and windows.
Code of Federal Regulations, 2014 CFR
2014-01-01
... loadings and flight loads, or compliance with the fail-safe requirements of paragraph (d) of this section... loads combined with critical aerodynamic pressure and temperature effects, after failure of any load... in front of the pilots must be arranged so that, assuming the loss of vision through any one panel...
14 CFR 23.775 - Windshields and windows.
Code of Federal Regulations, 2013 CFR
2013-01-01
... loadings and flight loads, or compliance with the fail-safe requirements of paragraph (d) of this section... loads combined with critical aerodynamic pressure and temperature effects, after failure of any load... in front of the pilots must be arranged so that, assuming the loss of vision through any one panel...
14 CFR 23.775 - Windshields and windows.
Code of Federal Regulations, 2012 CFR
2012-01-01
... loadings and flight loads, or compliance with the fail-safe requirements of paragraph (d) of this section... loads combined with critical aerodynamic pressure and temperature effects, after failure of any load... in front of the pilots must be arranged so that, assuming the loss of vision through any one panel...
42 CFR 71.3 - Designation of yellow fever vaccination centers; Validation stamps.
Code of Federal Regulations, 2010 CFR
2010-10-01
... safe, potent, and pure yellow fever vaccine. Medical facilities of Federal agencies are authorized to obtain yellow fever vaccine without being designated as a yellow fever vaccination center by the Director..., storage, and administration of yellow fever vaccine. If a designated center fails to comply with such...
ERIC Educational Resources Information Center
Waters, John K.
2009-01-01
Biometrics has been making its way into school districts for the past decade. Biometric tools draw information from a person's identifying physical components, providing a virtually fail-safe level of protection for K-12 schools. In addition to their security uses, biometric systems are currently used in schools for cafeteria purchases, library…
Power system monitoring and source control of the Space Station Freedom DC power system testbed
NASA Technical Reports Server (NTRS)
Kimnach, Greg L.; Baez, Anastacio N.
1992-01-01
Unlike a terrestrial electric utility which can purchase power from a neighboring utility, the Space Station Freedom (SSF) has strictly limited energy resources; as a result, source control, system monitoring, system protection, and load management are essential to the safe and efficient operation of the SSF Electric Power System (EPS). These functions are being evaluated in the DC Power Management and Distribution (PMAD) Testbed which NASA LeRC has developed at the Power System Facility (PSF) located in Cleveland, Ohio. The testbed is an ideal platform to develop, integrate, and verify power system monitoring and control algorithms. State Estimation (SE) is a monitoring tool used extensively in terrestrial electric utilities to ensure safe power system operation. It uses redundant system information to calculate the actual state of the EPS, to isolate faulty sensors, to determine source operating points, to verify faults detected by subsidiary controllers, and to identify high impedance faults. Source control and monitoring safeguard the power generation and storage subsystems and ensure that the power system operates within safe limits while satisfying user demands with minimal interruptions. System monitoring functions, in coordination with hardware implemented schemes, provide for a complete fault protection system. The objective of this paper is to overview the development and integration of the state estimator and the source control algorithms.
Power system monitoring and source control of the Space Station Freedom dc-power system testbed
NASA Technical Reports Server (NTRS)
Kimnach, Greg L.; Baez, Anastacio N.
1992-01-01
Unlike a terrestrial electric utility which can purchase power from a neighboring utility, the Space Station Freedom (SSF) has strictly limited energy resources; as a result, source control, system monitoring, system protection, and load management are essential to the safe and efficient operation of the SSF Electric Power System (EPS). These functions are being evaluated in the dc Power Management and Distribution (PMAD) Testbed which NASA LeRC has developed at the Power System Facility (PSF) located in Cleveland, Ohio. The testbed is an ideal platform to develop, integrate, and verify power system monitoring and control algorithms. State Estimation (SE) is a monitoring tool used extensively in terrestrial electric utilities to ensure safe power system operation. It uses redundant system information to calculate the actual state of the EPS, to isolate faulty sensors, to determine source operating points, to verify faults detected by subsidiary controllers, and to identify high impedance faults. Source control and monitoring safeguard the power generation and storage subsystems and ensure that the power system operates within safe limits while satisfying user demands with minimal interruptions. System monitoring functions, in coordination with hardware implemented schemes, provide for a complete fault protection system. The objective of this paper is to overview the development and integration of the state estimator and the source control algorithms.
Building the Leviathan – Voluntary centralisation of punishment power sustains cooperation in humans
Gross, Jörg; Méder, Zsombor Z.; Okamoto-Barth, Sanae; Riedl, Arno
2016-01-01
The prevalence of cooperation among humans is puzzling because cooperators can be exploited by free riders. Peer punishment has been suggested as a solution to this puzzle, but cumulating evidence questions its robustness in sustaining cooperation. Amongst others, punishment fails when it is not powerful enough, or when it elicits counter-punishment. Existing research, however, has ignored that the distribution of punishment power can be the result of social interactions. We introduce a novel experiment in which individuals can transfer punishment power to others. We find that while decentralised peer punishment fails to overcome free riding, the voluntary transfer of punishment power enables groups to sustain cooperation. This is achieved by non-punishing cooperators empowering those who are willing to punish in the interest of the group. Our results show how voluntary power centralisation can efficiently sustain cooperation, which could explain why hierarchical power structures are widespread among animals and humans. PMID:26888519
Building the Leviathan--Voluntary centralisation of punishment power sustains cooperation in humans.
Gross, Jörg; Méder, Zsombor Z; Okamoto-Barth, Sanae; Riedl, Arno
2016-02-18
The prevalence of cooperation among humans is puzzling because cooperators can be exploited by free riders. Peer punishment has been suggested as a solution to this puzzle, but cumulating evidence questions its robustness in sustaining cooperation. Amongst others, punishment fails when it is not powerful enough, or when it elicits counter-punishment. Existing research, however, has ignored that the distribution of punishment power can be the result of social interactions. We introduce a novel experiment in which individuals can transfer punishment power to others. We find that while decentralised peer punishment fails to overcome free riding, the voluntary transfer of punishment power enables groups to sustain cooperation. This is achieved by non-punishing cooperators empowering those who are willing to punish in the interest of the group. Our results show how voluntary power centralisation can efficiently sustain cooperation, which could explain why hierarchical power structures are widespread among animals and humans.
Power control of SAFE reactor using fuzzy logic
NASA Astrophysics Data System (ADS)
Irvine, Claude
2002-01-01
Controlling the 100 kW SAFE (Safe Affordable Fission Engine) reactor consists of design and implementation of a fuzzy logic process control system to regulate dynamic variables related to nuclear system power. The first phase of development concentrates primarily on system power startup and regulation, maintaining core temperature equilibrium, and power profile matching. This paper discusses the experimental work performed in those areas. Nuclear core power from the fuel elements is simulated using resistive heating elements while heat rejection is processed by a series of heat pipes. Both axial and radial nuclear power distributions are determined from neuronic modeling codes. The axial temperature profile of the simulated core is matched to the nuclear power profile by varying the resistance of the heating elements. The SAFE model establishes radial temperature profile equivalence by establishing 32 control zones as the nodal coordinates. Control features also allow for slow warm up, since complete shutoff can occur in the heat pipes if heat-source temperatures drop/rise below a certain minimum value, depending on the specific fluid and gas combination in the heat pipe. The entire system is expected to be self-adaptive, i.e., capable of responding to long-range changes in the space environment. Particular attention in the development of the fuzzy logic algorithm shall ensure that the system process remains at set point, virtually eliminating overshoot on start-up and during in-process disturbances. The controller design will withstand harsh environments and applications where it might come in contact with water, corrosive chemicals, radiation fields, etc. .
Safety considerations in the design and operation of large wind turbines
NASA Technical Reports Server (NTRS)
Reilly, D. H.
1979-01-01
The engineering and safety techniques used to assure the reliable and safe operation of large wind turbine generators utilizing the Mod 2 Wind Turbine System Program as an example is described. The techniques involve a careful definition of the wind turbine's natural and operating environments, use of proven structural design criteria and analysis techniques, an evaluation of potential failure modes and hazards, and use of a fail safe and redundant component engineering philosophy. The role of an effective quality assurance program, tailored to specific hardware criticality, and the checkout and validation program developed to assure system integrity are described.
Laser Safety Method For Duplex Open Loop Parallel Optical Link
Baumgartner, Steven John; Hedin, Daniel Scott; Paschal, Matthew James
2003-12-02
A method and apparatus are provided to ensure that laser optical power does not exceed a "safe" level in an open loop parallel optical link in the event that a fiber optic ribbon cable is broken or otherwise severed. A duplex parallel optical link includes a transmitter and receiver pair and a fiber optic ribbon that includes a designated number of channels that cannot be split. The duplex transceiver includes a corresponding transmitter and receiver that are physically attached to each other and cannot be detached therefrom, so as to ensure safe, laser optical power in the event that the fiber optic ribbon cable is broken or severed. Safe optical power is ensured by redundant current and voltage safety checks.
Enhancing future resilience in urban drainage system: Green versus grey infrastructure.
Dong, Xin; Guo, Hao; Zeng, Siyu
2017-11-01
In recent years, the concept transition from fail-safe to safe-to-fail makes the application of resilience analysis popular in urban drainage systems (UDSs) with various implications and quantifications. However, most existing definitions of UDSs resilience are confined to the severity of flooding, while uncertainties from climate change and urbanization are not considered. In this research, we take into account the functional variety, topological complexity, and disturbance randomness of UDSs and define a new formula of resilience based on three parts of system severity, i.e. social severity affected by urban flooding, environmental severity caused by sewer overflow, and technological severity considering the safe operation of downstream facilities. A case study in Kunming, China is designed to compare the effect of green and grey infrastructure strategies on the enhancement of system resilience together with their costs. Different system configurations with green roofs, permeable pavement and storage tanks are compared by scenario analysis with full consideration of future uncertainties induced by urbanization and climate change. The research contributes to the development of sustainability assessment of urban drainage system with consideration of the resilience of green and grey infrastructure under future change. Finding the response measures with high adaptation across a variety of future scenarios is crucial to establish sustainable urban drainage system in a long term. Copyright © 2017. Published by Elsevier Ltd.
14 CFR 121.313 - Miscellaneous equipment.
Code of Federal Regulations, 2011 CFR
2011-01-01
... equivalent for each pilot station. (c) A power supply and distribution system that meets the requirements of... external power supply if any one power source or component of the power distribution system fails. The use... on separate engines. (d) A means for indicating the adequacy of the power being supplied to required...
14 CFR 121.313 - Miscellaneous equipment.
Code of Federal Regulations, 2013 CFR
2013-01-01
... equivalent for each pilot station. (c) A power supply and distribution system that meets the requirements of... external power supply if any one power source or component of the power distribution system fails. The use... on separate engines. (d) A means for indicating the adequacy of the power being supplied to required...
14 CFR 121.313 - Miscellaneous equipment.
Code of Federal Regulations, 2014 CFR
2014-01-01
... equivalent for each pilot station. (c) A power supply and distribution system that meets the requirements of... external power supply if any one power source or component of the power distribution system fails. The use... on separate engines. (d) A means for indicating the adequacy of the power being supplied to required...
Experimental Evidence for Diagramming Benefits in Science Writing
ERIC Educational Resources Information Center
Barstow, Brendan; Fazio, Lisa; Schunn, Christian; Ashley, Kevin
2017-01-01
Arguing for the need for a scientific research study (i.e. writing an introduction to a research paper) poses significant challenges for students. When faced with these challenges, students often generate overly safe replications (i.e. fail to find and include opposition to their hypothesis) or in contrast include no strong support for their…
24 CFR 884.219 - Overcrowded and underoccupied units.
Code of Federal Regulations, 2010 CFR
2010-04-01
... assisted under this part is not Decent, Safe, and Sanitary by reason of increase in Family size, or that a Contract unit is larger than appropriate for the size of the Family in occupancy, housing assistance payments with respect to such unit will not be abated, unless the Owner fails to offer the Family a...
NASA Technical Reports Server (NTRS)
Westrup, R. W.
1971-01-01
The application of general design approaches for preventing failures due to repeated load cycles is briefly discussed. Program objective, mission requirements, and structural design criteria are summarized. Discrete structural elements and associated sections were selected for detailed strength, fatigue, and fracture mechanics investigations.
Filter holder assembly having extended collar spacer ring
Alvin, Mary Anne; Bruck, Gerald J.
2002-01-01
A filter holder assembly is provided that utilizes a fail-safe regenerator unit with an annular spacer ring having an extended metal collar for containment and positioning of a compliant ceramic gasket used in the assembly. The filter holder assembly is disclosed for use with advanced composite, filament wound, and metal candle filters.
Keeping Schools Safe during Tight Budget Times
ERIC Educational Resources Information Center
Trump, Kenneth S.
2010-01-01
Tight budgets are no excuse for failing to be proactive with school safety. In fact, school leaders must be especially committed to prevention and security programs during times when economic woes are increasing stress on kids, their families and school staff. Parents will forgive educators if their school's test scores drop. But they are much…
The Fail-Safe Micro Research Paper.
ERIC Educational Resources Information Center
Saunders, Mary Anne
A key element in a research paper writing assignment modified for students of English as a second language to assure their success is teacher control over most of the process. A chronological plan for action for the micro research project includes these steps: creating an awareness of current events and controversial issues, practicing necessary…
Accountable Game Design: Structuring the Dynamics of Student Learning Interactions
ERIC Educational Resources Information Center
Charoenying, Timothy
2010-01-01
Game-based classroom activity is intended to leverage students' interest and motivation to play, and to provide safe contexts for supporting students' academic learning. However, a basic criticism of many games currently used in classroom settings is that they can fail to meaningfully embody academic content. A more subtle concern is that…
Active Fail-Safe Micro-Array Flow Control for Advanced Embedded Propulsion Systems
NASA Technical Reports Server (NTRS)
Anderson, Bernhard H.; Mace, James L.; Mani, Mori
2009-01-01
The primary objective of this research effort was to develop and analytically demonstrate enhanced first generation active "fail-safe" hybrid flow-control techniques to simultaneously manage the boundary layer on the vehicle fore-body and to control the secondary flow generated within modern serpentine or embedded inlet S-duct configurations. The enhanced first-generation technique focused on both micro-vanes and micro-ramps highly-integrated with micro -jets to provide nonlinear augmentation for the "strength' or effectiveness of highly-integrated flow control systems. The study focused on the micro -jet mass flow ratio (Wjet/Waip) range from 0.10 to 0.30 percent and jet total pressure ratios (Pjet/Po) from 1.0 to 3.0. The engine bleed airflow range under study represents about a 10 fold decrease in micro -jet airflow than previously required. Therefore, by pre-conditioning, or injecting a very small amount of high-pressure jet flow into the vortex generated by the micro-vane and/or micro-ramp, active flow control is achieved and substantial augmentation of the controlling flow is realized.
Flow Structures and Interactions of a Fail-Safe Actuator
NASA Astrophysics Data System (ADS)
Khan, Wasif; Elimelech, Yoseph; Amitay, Michael
2010-11-01
Vortex generators are passive devices that are commonly used in many aerodynamic applications. In their basic concept, they enhance mixing, reduce or mitigate flow separation; however, they cause drag penalties at off design conditions. Micro vanes implement the same basic idea of vortex generators but their physical dimensions are much smaller. To achieve the same effect on the baseline flow field, micro vanes are combined with an active flow control device, so their net effect is comparable to that of vortex generators when the active device is energized. As a result of their small size, micro vanes have significantly less drag penalty at off design conditions. This concept of "dual-action" is the reason why such actuation is commonly called hybrid or fail-safe actuation. The present study explores experimentally the flow interaction of a synthetic-jet with a micro vane in a zero pressure gradient flow over a flat plate. Using the stereo particle image velocimetry technique a parametric study was conducted, where the effects of the micro vane shape, height and its angle with respect to the flow were examined, at several blowing ratios and synthetic-jet configurations.
Diculescu, Mircea; Ciocîrlan, Mihai; Ciocîrlan, Mirela; Piţigoi, Dan; Becheanu, Gabriel; Croitoru, Adina; Spanache, Sandu
2003-12-01
The purpose of the study was to assess whether folic acid supplementation and long term therapy with sulfasalazine can reduce the risk of colorectal cancer (CRC) development in longstanding extensive ulcerative colitis. A meta-analysis was performed including the last 10 years published and Medline indexed studies on this subject. 3 studies have been included concerning the protective effect of folate supplementation in development of CRC. The association of these two factors is significant (effect size r =0.124, p = 0.025). The fail-safe number of studies with an opposite result should be 4 to revert the significance. 4 studies regarding sulfasalazine's protective effect in longstanding extensive ulcerative colitis have also been evaluated. A similar significance has been obtained, r = 0.148, p = 0.0007 and a fail-safe number of studies equal to 7. The homogeneity of these studies is validated by standard tests. Both sulfasalazine therapy and folate supplementation have a protective effect in colorectal cancer development in a population of patients with longstanding ulcerative colitis. Randomized controlled trials are needed to explore these hypotheses.
NASA Technical Reports Server (NTRS)
Hrbud, Ivana; VanDyke, Melissa; Houts, Mike; Goodfellow, Keith; Schafer, Charles (Technical Monitor)
2001-01-01
The Safe Affordable Fission Engine (SAFE) test series addresses Phase 1 Space Fission Systems issues in particular non-nuclear testing and system integration issues leading to the testing and non-nuclear demonstration of a 400-kW fully integrated flight unit. The first part of the SAFE 30 test series demonstrated operation of the simulated nuclear core and heat pipe system. Experimental data acquired in a number of different test scenarios will validate existing computational models, demonstrated system flexibility (fast start-ups, multiple start-ups/shut downs), simulate predictable failure modes and operating environments. The objective of the second part is to demonstrate an integrated propulsion system consisting of a core, conversion system and a thruster where the system converts thermal heat into jet power. This end-to-end system demonstration sets a precedent for ground testing of nuclear electric propulsion systems. The paper describes the SAFE 30 end-to-end system demonstration and its subsystems.
Advanced orbit transfer vehicle propulsion system study
NASA Technical Reports Server (NTRS)
Cathcart, J. A.; Cooper, T. W.; Corringrato, R. M.; Cronau, S. T.; Forgie, S. C.; Harder, M. J.; Mcallister, J. G.; Rudman, T. J.; Stoneback, V. W.
1985-01-01
A reuseable orbit transfer vehicle concept was defined and subsequent recommendations for the design criteria of an advanced LO2/LH2 engine were presented. The major characteristics of the vehicle preliminary design include a low lift to drag aerocapture capability, main propulsion system failure criteria of fail operational/fail safe, and either two main engines with an attitude control system for backup or three main engines to meet the failure criteria. A maintenance and servicing approach was also established for the advanced vehicle and engine concepts. Design tradeoff study conclusions were based on the consideration of reliability, performance, life cycle costs, and mission flexibility.
2017-05-25
government failed to get universal support from either the Chinese population or the Western powers . This is particularly so in the case of the foreign...ability to understand the underlying contexts of an interaction and adjusting behavior to avoid disruption when it fails to meet expectations and is...beginning of the break down in Manchu power and rising discontent of the Han people .76 The overall poor performance of the Qing military, both by Han
McConnell, Jennifer A; Schaffner, Donald W
2014-07-01
Temperature is a primary factor in controlling the growth of microorganisms in food. The current U. S. Food and Drug Administration Model Food Code guidelines state that food can be kept out of temperature control for up to 4 h without qualifiers, or up to 6 h, if the food product starts at an initial 41 °F (5 °C) temperature and does not exceed 70 °F (21 °C) at 6 h. This project validates existing ComBase computer models for Salmonella growth under changing temperature conditions modeling scenarios using raw ground beef as a model system. A cocktail of Salmonella serovars isolated from different meat products ( Salmonella Copenhagen, Salmonella Montevideo, Salmonella Typhimurium, Salmonella Saintpaul, and Salmonella Heidelberg) was made rifampin resistant and used for all experiments. Inoculated samples were held in a programmable water bath at 4.4 °C (40 °F) and subjected to linear temperature changes to different final temperatures over various lengths of time and then returned to 4.4 °C (40 °F). Maximum temperatures reached were 15.6, 26.7, or 37.8 °C (60, 80, or 100 °F), and the temperature increases took place over 4, 6, and 8 h, with varying cooling times. Our experiments show that when maximum temperatures were lower (15.6 or 26.7 °C), there was generally good agreement between the ComBase models and experiments: when temperature increases of 15.6 or 26.7 °C occurred over 8 h, experimental data were within 0.13 log CFU of the model predictions. When maximum temperatures were 37 °C, predictive models were fail-safe. Overall bias of the models was 1.11. and accuracy was 2.11. Our experiments show the U.S. Food and Drug Administration Model Food Code guidelines for holding food out of temperature control are quite conservative. Our research also shows that the ComBase models for Salmonella growth are accurate or fail-safe for dynamic temperature conditions as might be observed due to power loss from natural disasters or during transport out of temperature control.
APOLLO COMMAND MODULE (CM) - SAFE TOUCHDOWN - PACIFIC OCEAN
1971-08-07
S71-41999 (7 Aug. 1971) --- The Apollo 15 Command Module (CM), with astronauts David R. Scott, commander; Alfred M. Worden, command module pilot; and James B. Irwin, lunar module pilot, aboard, nears a safe touchdown in the mid-Pacific Ocean to conclude a highly successful lunar landing mission. Although causing no harm to the crewmen, one of the three main parachutes failed to function properly. The splashdown occurred at 3:45:53 p.m. (CDT), Aug. 7, 1971, some 330 miles north of Honolulu, Hawaii. The three astronauts were picked up by helicopter and flown to the prime recovery ship USS Okinawa, which was only 6 1/2 miles away.
Fail-safe transcription termination: Because one is never enough
Lemay, Jean-François; Bachand, François
2015-01-01
Termination of RNA polymerase II (RNAPII) transcription is a fundamental step of gene expression that involves the release of the nascent transcript and dissociation of RNAPII from the DNA template. As transcription termination is intimately linked to RNA 3′ end processing, termination pathways have a key decisive influence on the fate of the transcribed RNA. Quite remarkably, when reaching the 3′ end of genes, a substantial fraction of RNAPII fail to terminate transcription, requiring the contribution of alternative or “fail-safe” mechanisms of termination to release the polymerase. This point of view covers redundant mechanisms of transcription termination and how they relate to conventional termination models. In particular, we expand on recent findings that propose a reverse torpedo model of termination, in which the 3′5′ exonucleolytic activity of the RNA exosome targets transcription events associated with paused and backtracked RNAPII. PMID:26273910
Code of Federal Regulations, 2010 CFR
2010-10-01
... power TV, TV translator, digital low power TV and digital TV translator stations. 73.6019 Section 73... low power TV, TV translator, digital low power TV and digital TV translator stations. An application... A TV station will not be accepted if it fails to protect authorized low power TV, TV translator...
The Presence of the Correlates of Effective Schools at the District Level: A Case Study
ERIC Educational Resources Information Center
Thompson, DeNelle
2013-01-01
Although the No Child Left Behind Act (NCLB) requires all American public schools to meet Adequate Yearly Progress (AYP), many fail to meet this standard each year. Effective Schools Research has revealed several correlates, such as a clear mission, a safe climate, strong instructional leadership, monitoring of student progress, strong…
28 CFR 90.106 - What are the grantee reporting requirements for the grant program?
Code of Federal Regulations, 2010 CFR
2010-07-01
... (CONTINUED) VIOLENCE AGAINST WOMEN Grants To Combat Violent Crimes Against Women on Campuses § 90.106 What..., Violence Against Women Office). Funding shall be suspended if a grantee fails to submit an annual..., Violence Against Women Office) and the Secretary of Education (U.S. Department of Education's Safe and Drug...
Is the cervical spine clear? Undetected cervical fractures diagnosed only at autopsy.
Sweeney, J F; Rosemurgy, A S; Gill, S; Albrink, M H
1992-10-01
Undetected cervical-spine injuries are a nemesis to both trauma surgeons and emergency physicians. Radiographic protocols have been developed to avoid missing cervical-spine fractures but are not fail-safe. Three case reports of occult cervical fractures documented at autopsy in the face of normal cervical-spine radiographs and computerized tomography scans are presented.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-16
... international cargo shipping; Respondent Njoroge Muhia is Chief Executive Officer for African Shipping... containers and chassis to Mombasa Kenya, violated Section 10(d)(1) of the Shipping Act, 46 U.S.C. 41102(c), by ``failing to ensure that Ms. Barbara[`s] (sic) container was delivered safely, securely and on...
A Matter of Money? Policy Analysis of Rural Boarding Schools in China
ERIC Educational Resources Information Center
Zhao, Zhenzhou
2011-01-01
The Chinese government has shifted the pattern of rural schooling over the past decade, replacing village schools with urban boarding schools. The stated goal is to improve school quality, while deploying resources more effectively. However, the new boarding schools fail to provide a safe, healthy environment or protect and enable students' human…
Battery Control Algorithms | Transportation Research | NREL
publications. Accounting for Lithium-Ion Battery Degradation in Electric Vehicle Charging Optimization Advanced Reformulation of Lithium-Ion Battery Models for Enabling Electric Transportation Fail-Safe Design for Large Capacity Lithium-Ion Battery Systems Contact Ying Shi Email | 303-275-4240
Rotating assembly working group summary
NASA Technical Reports Server (NTRS)
Kulkarni, S. V.
1984-01-01
The feasibility of a fail safe flywheel system was demonstrated. Three of the major advantages of flywheel systems are: longer operational life, higher electrical efficiency, and higher system energy density. The use of composite material flywheels is important to realize these advantages. Rotor design and dynamics, rotor materials and fabrication, safety, nondestructive testing, and systems operation loads and environment, are outlined.
Bryce, Thomas N.; Dijkers, Marcel P.
2015-01-01
Background: Powered exoskeletons have been demonstrated as being safe for persons with spinal cord injury (SCI), but little is known about how users learn to manage these devices. Objective: To quantify the time and effort required by persons with SCI to learn to use an exoskeleton for assisted walking. Methods: A convenience sample was enrolled to learn to use the first-generation Ekso powered exoskeleton to walk. Participants were given up to 24 weekly sessions of instruction. Data were collected on assistance level, walking distance and speed, heart rate, perceived exertion, and adverse events. Time and effort was quantified by the number of sessions required for participants to stand up, walk for 30 minutes, and sit down, initially with minimal and subsequently with contact guard assistance. Results: Of 22 enrolled participants, 9 screen-failed, and 7 had complete data. All of these 7 were men; 2 had tetraplegia and 5 had motor-complete injuries. Of these, 5 participants could stand, walk, and sit with contact guard or close supervision assistance, and 2 required minimal to moderate assistance. Walk times ranged from 28 to 94 minutes with average speeds ranging from 0.11 to 0.21 m/s. For all participants, heart rate changes and reported perceived exertion were consistent with light to moderate exercise. Conclusion: This study provides preliminary evidence that persons with neurological weakness due to SCI can learn to walk with little or no assistance and light to somewhat hard perceived exertion using a powered exoskeleton. Persons with different severities of injury, including those with motor complete C7 tetraplegia and motor incomplete C4 tetraplegia, may be able to learn to use this device. PMID:26364280
Kozlowski, Allan J; Bryce, Thomas N; Dijkers, Marcel P
2015-01-01
Powered exoskeletons have been demonstrated as being safe for persons with spinal cord injury (SCI), but little is known about how users learn to manage these devices. To quantify the time and effort required by persons with SCI to learn to use an exoskeleton for assisted walking. A convenience sample was enrolled to learn to use the first-generation Ekso powered exoskeleton to walk. Participants were given up to 24 weekly sessions of instruction. Data were collected on assistance level, walking distance and speed, heart rate, perceived exertion, and adverse events. Time and effort was quantified by the number of sessions required for participants to stand up, walk for 30 minutes, and sit down, initially with minimal and subsequently with contact guard assistance. Of 22 enrolled participants, 9 screen-failed, and 7 had complete data. All of these 7 were men; 2 had tetraplegia and 5 had motor-complete injuries. Of these, 5 participants could stand, walk, and sit with contact guard or close supervision assistance, and 2 required minimal to moderate assistance. Walk times ranged from 28 to 94 minutes with average speeds ranging from 0.11 to 0.21 m/s. For all participants, heart rate changes and reported perceived exertion were consistent with light to moderate exercise. This study provides preliminary evidence that persons with neurological weakness due to SCI can learn to walk with little or no assistance and light to somewhat hard perceived exertion using a powered exoskeleton. Persons with different severities of injury, including those with motor complete C7 tetraplegia and motor incomplete C4 tetraplegia, may be able to learn to use this device.
CloudSat Anomaly Recovery and Operational Lessons Learned
NASA Technical Reports Server (NTRS)
Witkowski, Mona; Vane, Deborah; Livermore, Thomas; Rokey, Mark; Barthuli, Marda; Gravseth, Ian J.; Pieper, Brian; Rodzinak, Aaron; Silva, Steve; Woznick, Paul;
2012-01-01
In April 2011, NASA's pioneering cloud profiling radar satellite, CloudSat, experienced a battery anomaly that placed it into emergency mode and rendered it operations incapable. All initial attempts to recover the spacecraft failed as the resultant power limitations could not support even the lowest power mode. Originally part of a six-satellite constellation known as the "A-Train", CloudSat was unable to stay within its assigned control box, posing a threat to other A-Train satellites. CloudSat needed to exit the constellation, but with the tenuous power profile, conducting maneuvers was very risky. The team was able to execute a complex sequence of operations which recovered control, conducted an orbit lower maneuver, and returned the satellite to safe mode, within one 65 minute sunlit period. During the course of the anomaly recovery, the team developed several bold, innovative operational strategies. Details of the investigation into the root-cause and the multiple approaches to revive CloudSat are examined. Satellite communication and commanding during the anomaly are presented. A radical new system of "Daylight Only Operations" (DO-OP) was developed, which cycles the payload and subsystem components off in tune with earth eclipse entry and exit in order to maintain positive power and thermal profiles. The scientific methodology and operational results behind the graduated testing and ramp-up to DO-OP are analyzed. In November 2011, the CloudSat team successfully restored the vehicle to consistent operational collection of cloud radar data during sunlit portions of the orbit. Lessons learned throughout the six-month return-to-operations recovery effort are discussed and offered for application to other R&D satellites, in the context of on-orbit anomaly resolution efforts.
Evaluation of the safety and durability of low-cost nonprogrammable electric powered wheelchairs.
Pearlman, Jonathan L; Cooper, Rory A; Karnawat, Jaideep; Cooper, Rosemarie; Boninger, Michael L
2005-12-01
To evaluate whether a selection of low-cost, nonprogrammable electric-powered wheelchairs (EPWs) meets the American National Standards Institute (ANSI)/Rehabilitation Engineering and Assistive Technology Society of North America (RESNA) Wheelchair Standards requirements. Objective comparison tests of various aspects of power wheelchair design and performance of 4 EPW types. Three of each of the following EPWs: Pride Mobility Jet 10 (Pride), Invacare Pronto M50 (Invacare), Electric Mobility Rascal 250PC (Electric Mobility), and the Golden Technologies Alanté GP-201-F (Golden). Rehabilitation engineering research center. Not applicable. Static tipping angle; dynamic tipping score; braking distance; energy consumption; climatic conditioning; power and control systems integrity and safety; and static, impact, and fatigue life (equivalent cycles). Static tipping angle and dynamic tipping score were significantly different across manufacturers for each tipping direction (range, 6.6 degrees-35.6 degrees). Braking distances were significantly different across manufacturers (range, 7.4-117.3 cm). Significant differences among groups were found with analysis of variance (ANOVA). Energy consumption results show that all EPWs can travel over 17 km before the battery is expected to be exhausted under idealized conditions (range, 18.2-32.0 km). Significant differences among groups were found with ANOVA. All EPWs passed the climatic conditioning tests. Several adverse responses were found during the power and control systems testing, including motors smoking during the stalling condition (Electric Mobility), charger safety issues (Electric Mobility, Invacare), and controller failures (Golden). All EPWs passed static and impact testing; 9 of 12 failed fatigue testing (3 Invacare, 3 Golden, 1 Electric Mobility, 2 Pride). Equivalent cycles did not differ statistically across manufacturers (range, 9759-824,628 cycles). Large variability in the results, especially with respect to static tipping, power and control system failures, and fatigue life suggest design improvements must be made to make these low-cost, nonprogrammable EPWs safe and reliable for the consumer. Based on our results, these EPWs do not, in general, meet the ANSI/RESNA Wheelchair Standards requirements.
A wireless power transmission system for an active capsule endoscope for colon inspection.
Jia, Zhiwei; Yan, Guozheng; Shi, Yu; Zhu, Bingquan
2012-07-01
Multipurpose active capsule endoscopes (ACE) have drawn considerable attention in recent years, but these devices continue to suffer from energy limitations. In order to deliver stable and sufficient energy safely, a wireless power transmission system based on inductive coupling is presented. The system consists of a double-layer solenoid pair primary coil outside and a multiple secondary coils inside the body. At least 500 mW usable power can be transmitted under the worst geometrical conditions and the safety restraints in a volume of Φ13 × 13 mm. The wireless power transmission system is integrated to an ACE and applied in animal experiments. The designed wireless power transmission is proved to be feasible and potentially safe in a future application.
U.S. spacewalk on ISS on This Week @NASA - October 10, 2014
2014-10-10
Aboard the International Space Station, Expedition 41 Flight Engineers Reid Wiseman of NASA and Alexander Gerst of the European Space Agency donned U.S. spacesuits for an October 7 spacewalk to relocate a failed cooling pump and to install a backup power cable device for the station’s rail car system. The failed pump was replaced with a spare and is being temporarily stowed near the Quest airlock and the back-up power cables are for the unlikely event that the Mobile Transporter rail car on the station’s truss loses power. Also, A comet’s Mars flyby, Brightest pulsar! Total Lunar Eclipse and LADEE wins Popular Mechanics award!
Method of locating a leaking fuel element in a fast breeder power reactor
Honekamp, John R.; Fryer, Richard M.
1978-01-01
Leaking fuel elements in a fast reactor are identified by measuring the ratio of .sup.134 Xe to .sup.133 Xe in the reactor cover gas following detection of a fuel element leak, this ratio being indicative of the power and burnup of the failed fuel element. This procedure can be used to identify leaking fuel elements in a power breeder reactor while continuing operation of the reactor since the ratio measured is that of the gases stored in the plenum of the failed fuel element. Thus, use of a cleanup system for the cover gas makes it possible to identify sequentially a multiplicity of leaking fuel elements without shutting the reactor down.
Clinical assessment of pacemaker power sources
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bilitch, M.; Parsonnet, V.; Furman, S.
1980-01-01
The development of power sources for cardiac pacemakers has progressed from a 15-year usage of mercury-zinc batteries to widely used and accepted lithium cells. At present, there are about 6 different types of lithium cells incorporated into commercially distributed pacemakers. The authors reviewed experience over a 5-year period with 1711 mercury-zinc, 130 nuclear (P238) and 1912 lithium powered pacemakers. The lithium units have included 698 lithium-iodide, 270 lithium-silver chromate, 135 lithium-thionyl chloride, 31 lithium-lead and 353 lithium-cupric sulfide batteries. 57 of the lithium units have failed (91.2% component failure and 5.3% battery failure). 459 mercury-zinc units failed (25% component failuremore » and 68% battery depletion). The data show that lithium powered pacemaker failures are primarily component, while mercury-zinc failures are primarily battery related. It is concluded that mercury-zinc powered pulse generators are obsolete and that lithium and nuclear (P238) power sources are highly reliable over the 5 years for which data are available. 3 refs.« less
Quasistatic Cavity Resonance for Ubiquitous Wireless Power Transfer.
Chabalko, Matthew J; Shahmohammadi, Mohsen; Sample, Alanson P
2017-01-01
Wireless power delivery has the potential to seamlessly power our electrical devices as easily as data is transmitted through the air. However, existing solutions are limited to near contact distances and do not provide the geometric freedom to enable automatic and un-aided charging. We introduce quasistatic cavity resonance (QSCR), which can enable purpose-built structures, such as cabinets, rooms, and warehouses, to generate quasistatic magnetic fields that safely deliver kilowatts of power to mobile receivers contained nearly anywhere within. A theoretical model of a quasistatic cavity resonator is derived, and field distributions along with power transfer efficiency are validated against measured results. An experimental demonstration shows that a 54 m3 QSCR room can deliver power to small coil receivers in nearly any position with 40% to 95% efficiency. Finally, a detailed safety analysis shows that up to 1900 watts can be transmitted to a coil receiver enabling safe and ubiquitous wireless power.
Quasistatic Cavity Resonance for Ubiquitous Wireless Power Transfer
Shahmohammadi, Mohsen; Sample, Alanson P.
2017-01-01
Wireless power delivery has the potential to seamlessly power our electrical devices as easily as data is transmitted through the air. However, existing solutions are limited to near contact distances and do not provide the geometric freedom to enable automatic and un-aided charging. We introduce quasistatic cavity resonance (QSCR), which can enable purpose-built structures, such as cabinets, rooms, and warehouses, to generate quasistatic magnetic fields that safely deliver kilowatts of power to mobile receivers contained nearly anywhere within. A theoretical model of a quasistatic cavity resonator is derived, and field distributions along with power transfer efficiency are validated against measured results. An experimental demonstration shows that a 54 m3 QSCR room can deliver power to small coil receivers in nearly any position with 40% to 95% efficiency. Finally, a detailed safety analysis shows that up to 1900 watts can be transmitted to a coil receiver enabling safe and ubiquitous wireless power. PMID:28199321
49 CFR 393.23 - Power supply for lamps.
Code of Federal Regulations, 2014 CFR
2014-10-01
... NECESSARY FOR SAFE OPERATION Lamps, Reflective Devices, and Electrical Wiring § 393.23 Power supply for lamps. All required lamps must be powered by the electrical system of the motor vehicle with the...
Malpractice liability, technology choice and negative defensive medicine.
Feess, Eberhard
2012-04-01
We extend the theoretical literature on the impact of malpractice liability by allowing for two treatment technologies, a safe and a risky one. The safe technology bears no failure risk, but leads to patient-specific disutility since it cannot completely solve the health problems. By contrast, the risky technology (for instance a surgery) may entirely cure patients, but fail with some probability depending on the hospital's care level. Tight malpractice liability increases care levels if the risky technology is chosen at all, but also leads to excessively high incentives for avoiding the liability exposure by adopting the safe technology. We refer to this distortion toward the safe technology as negative defensive medicine. Taking the problem of negative defensive medicine seriously, the second best optimal liability needs to balance between the over-incentive for the safe technology in case of tough liability and the incentive to adopt little care for the risky technology in case of weak liability. In a model with errors in court, we find that gross negligence where hospitals are held liable only for very low care levels outperforms standard negligence, even though standard negligence would implement the first best efficient care level.
A 0.2 V Micro-Electromechanical Switch Enabled by a Phase Transition.
Dong, Kaichen; Choe, Hwan Sung; Wang, Xi; Liu, Huili; Saha, Bivas; Ko, Changhyun; Deng, Yang; Tom, Kyle B; Lou, Shuai; Wang, Letian; Grigoropoulos, Costas P; You, Zheng; Yao, Jie; Wu, Junqiao
2018-04-01
Micro-electromechanical (MEM) switches, with advantages such as quasi-zero leakage current, emerge as attractive candidates for overcoming the physical limits of complementary metal-oxide semiconductor (CMOS) devices. To practically integrate MEM switches into CMOS circuits, two major challenges must be addressed: sub 1 V operating voltage to match the voltage levels in current circuit systems and being able to deliver at least millions of operating cycles. However, existing sub 1 V mechanical switches are mostly subject to significant body bias and/or limited lifetimes, thus failing to meet both limitations simultaneously. Here 0.2 V MEM switching devices with ≳10 6 safe operating cycles in ambient air are reported, which achieve the lowest operating voltage in mechanical switches without body bias reported to date. The ultralow operating voltage is mainly enabled by the abrupt phase transition of nanolayered vanadium dioxide (VO 2 ) slightly above room temperature. The phase-transition MEM switches open possibilities for sub 1 V hybrid integrated devices/circuits/systems, as well as ultralow power consumption sensors for Internet of Things applications. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Environmental Control and Life Support Systems Test Facility at MSFC
NASA Technical Reports Server (NTRS)
2001-01-01
The Marshall Space Flight Center (MSFC) is responsible for designing and building the life support systems that will provide the crew of the International Space Station (ISS) a comfortable environment in which to live and work. Scientists and engineers at the MSFC are working together to provide the ISS with systems that are safe, efficient, and cost-effective. These compact and powerful systems are collectively called the Environmental Control and Life Support Systems, or simply, ECLSS. In this photograph, the life test area on the left of the MSFC ECLSS test facility is where various subsystems and components are tested to determine how long they can operate without failing and to identify components needing improvement. Equipment tested here includes the Carbon Dioxide Removal Assembly (CDRA), the Urine Processing Assembly (UPA), the mass spectrometer filament assemblies and sample pumps for the Major Constituent Analyzer (MCA). The Internal Thermal Control System (ITCS) simulator facility (in the module in the right) duplicates the function and operation of the ITCS in the ISS U.S. Laboratory Module, Destiny. This facility provides support for Destiny, including troubleshooting problems related to the ITCS.
PFBC HGCU Test Facility. Technical progress report No. 24, Third quarter, CY 1995
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
This is the twenty-fourth and final Technical Progress Report submitted to the Department of Energy (DOE) in connection with the cooperative agreement between the DOE and Ohio Power Company for the Tidd PFBC Hot Gas Clean Up Test Facility. This report covers the work completed during the Third Quarter of CY 1995. All activity this quarter was directed toward the completion of the program final report. A draft copy of the final report was forwarded to DOE during this quarter, and DOE submitted their comments on the report to AEPSC. DOE requested that Westinghouse write an appendix to the reportmore » covering the performance of the fail-safe regenerator devices during Tad operation, and Westinghouse subsequently prepared the appendix. Additional DOE comments were incorporated into the report, and it will be issued in camera-ready form by the end of October, 1995, which is the program end date. Appendix 1 presents the results of filter candle posttest examination by Westinghouse performed on selected filter candles following final shutdown of the system.« less
International Space Station (ISS)
2001-02-01
The Marshall Space Flight Center (MSFC) is responsible for designing and building the life support systems that will provide the crew of the International Space Station (ISS) a comfortable environment in which to live and work. Scientists and engineers at the MSFC are working together to provide the ISS with systems that are safe, efficient, and cost-effective. These compact and powerful systems are collectively called the Environmental Control and Life Support Systems, or simply, ECLSS. In this photograph, the life test area on the left of the MSFC ECLSS test facility is where various subsystems and components are tested to determine how long they can operate without failing and to identify components needing improvement. Equipment tested here includes the Carbon Dioxide Removal Assembly (CDRA), the Urine Processing Assembly (UPA), the mass spectrometer filament assemblies and sample pumps for the Major Constituent Analyzer (MCA). The Internal Thermal Control System (ITCS) simulator facility (in the module in the right) duplicates the function and operation of the ITCS in the ISS U.S. Laboratory Module, Destiny. This facility provides support for Destiny, including troubleshooting problems related to the ITCS.
Technical aspects of the Space Telescope Imaging Spectrograph Repair (STIS-R)
NASA Astrophysics Data System (ADS)
Rinehart, S. A.; Domber, J.; Faulkner, T.; Gull, T.; Kimble, R.; Klappenberger, M.; Leckrone, D.; Niedner, M.; Proffitt, C.; Smith, H.; Woodgate, B.
2008-07-01
In August 2004, the Hubble Space Telescope (HST) Space Telescope Imaging Spectrograph (STIS) ceased operation due to a failure of the 5V mechanism power converter in the Side 2 Low Voltage Power Supply (LVPS2). The failure precluded movement of any STIS mechanism and, because of the earlier (2001) loss of the Side 1 electronics chain, left the instrument shuttered and in safe mode after 7.5 years of science operations. A team was assembled to analyze the fault and to determine if STIS repair (STIS-R) was feasible. The team conclusively pinpointed the Side 2 failure to the 5V mechanism converter, and began studying EVA techniques for opening STIS during Servicing Mission 4 (SM4) to replace the failed LVPS2 board. The restoration of STIS functionality via surgical repair by astronauts has by now reached a mature and final design state, and will, along with a similar repair procedure for the Advanced Camera for Surveys (ACS), represent a first for Hubble servicing. STIS-R will restore full scientific functionality of the spectrograph on Side 2, while Side 1 will remain inoperative. Because of the high degree of complementarity between STIS and the new Cosmic Origins Spectrograph (COS, to be installed during SM4)), successful repair of the older spectrograph is an important scientific objective. In this presentation, we focus on the technical aspects associated with STIS-R.
NASA Technical Reports Server (NTRS)
Liu, A. F.
1974-01-01
A systematic approach for applying methods for fracture control in the structural components of space vehicles consists of four major steps. The first step is to define the primary load-carrying structural elements and the type of load, environment, and design stress levels acting upon them. The second step is to identify the potential fracture-critical parts by means of a selection logic flow diagram. The third step is to evaluate the safe-life and fail-safe capabilities of the specified part. The last step in the sequence is to apply the control procedures that will prevent damage to the fracture-critical parts. The fracture control methods discussed include fatigue design and analysis methods, methods for preventing crack-like defects, fracture mechanics analysis methods, and nondestructive evaluation methods. An example problem is presented for evaluation of the safe-crack-growth capability of the space shuttle crew compartment skin structure.
Enron's Ethical Collapse: Lessons for Leadership Educators
ERIC Educational Resources Information Center
Johnson, Craig
2003-01-01
Top officials at Enron abused their power and privileges, manipulated information, engaged in inconsistent treatment of internal and external constituencies, put their own interests above those of their employees and the public, and failed to exercise proper oversight or shoulder responsibility for ethical failings. Followers were all too quick to…
Extinction measurements with low-power hsrl systems—error limits
NASA Astrophysics Data System (ADS)
Eloranta, Ed
2018-04-01
HSRL measurements of extinction are more difficult than backscatter measurements. This is particularly true for low-power, eye-safe systems. This paper looks at error sources that currently provide an error limit of 10-5 m-1 for boundary layer extinction measurements made with University of Wisconsin HSRL systems. These eye-safe systems typically use 300mW transmitters and 40 cm diameter receivers with a 10-4 radian field-of-view.
Nuclear Energy: It is Time to Revitalize the Peaceful Atom
2011-03-16
difficulties of obtaining NRC licensing approval since the NRC had to evaluate each individual design.26 Nuclear Waste James Lovelock , an...OfNuclearPower (accessed December 26, 2010). 25 Ibid. 26 Ibid. 27 James Lovelock , “Nuclear Energy: The Safe Choice for Now,” Environmentalists for Nuclear...Energy, July 2005, http://www.ecolo.org/ lovelock /nuclear-safe-choice-05.htm (accessed 27 December 2010). 28 Caldicott, Nuclear Power is Not the Answer
Hou, Huidan; Xu, Qingkai; Pang, Yaokun; Li, Lei; Wang, Jiulin; Zhang, Chi; Sun, Chunwen
2017-08-01
Storing energy harvested by triboelectric nanogenerators (TENGs) from ambient mechanical motion is still a great challenge for achieving low-cost and environmental benign power sources. Here, an all-solid-state Na-ion battery with safe and durable performance used for efficient storing pulsed energy harvested by the TENG is demonstrated. The solid-state sodium-ion batteries are charged by galvanostatic mode and pulse mode with the TENG, respectively. The all-solid-state sodium-ion battery displays excellent cyclic performance up to 1000 cycles with a capacity retention of about 85% even at a high charge and discharge current density of 48 mA g -1 . When charged by the TENG, an energy conversion efficiency of 62.3% is demonstrated. The integration of TENGs with the safe and durable all-solid-state sodium-ion batteries is potential for providing more stable power output for self-powered systems.
26 CFR 1.121-3 - Reduced maximum exclusion for taxpayers failing to meet certain requirements.
Code of Federal Regulations, 2014 CFR
2014-04-01
... by reason of a change in place of employment, health, or unforeseen circumstances. If a safe harbor described in this section applies, a sale or exchange is deemed to be by reason of a change in place of... sale or exchange is by reason of a change in place of employment, health, or unforeseen circumstances...
26 CFR 1.121-3 - Reduced maximum exclusion for taxpayers failing to meet certain requirements.
Code of Federal Regulations, 2013 CFR
2013-04-01
... by reason of a change in place of employment, health, or unforeseen circumstances. If a safe harbor described in this section applies, a sale or exchange is deemed to be by reason of a change in place of... sale or exchange is by reason of a change in place of employment, health, or unforeseen circumstances...
26 CFR 1.121-3 - Reduced maximum exclusion for taxpayers failing to meet certain requirements.
Code of Federal Regulations, 2011 CFR
2011-04-01
... by reason of a change in place of employment, health, or unforeseen circumstances. If a safe harbor described in this section applies, a sale or exchange is deemed to be by reason of a change in place of... sale or exchange is by reason of a change in place of employment, health, or unforeseen circumstances...
26 CFR 1.121-3 - Reduced maximum exclusion for taxpayers failing to meet certain requirements.
Code of Federal Regulations, 2012 CFR
2012-04-01
... by reason of a change in place of employment, health, or unforeseen circumstances. If a safe harbor described in this section applies, a sale or exchange is deemed to be by reason of a change in place of... sale or exchange is by reason of a change in place of employment, health, or unforeseen circumstances...
Toward A Fail-Safe Air Force Culture: Creating a Resilient Future While Avoiding Past Mistakes
2012-10-01
process often uses the “ Swiss cheese ” model to evaluate accidents. The image of holes in the protective cheese layers (proactive and reactive measures...minimize the number and size of holes in each slice of cheese . More importantly, however, a HRO’s 16 focus is on “the process of the slices lining up as
ERIC Educational Resources Information Center
Machajewski, Szymon
2017-01-01
Schools are to prepare students for success. However, they often villainize failure. Instead, schools should teach students how to fail fast and safely in order to learn and to allow innovation through vulnerability. The lessons that the gaming culture has for learning will define future strategies of teaching and learning. Games are sometimes…
26 CFR 1.121-3 - Reduced maximum exclusion for taxpayers failing to meet certain requirements.
Code of Federal Regulations, 2010 CFR
2010-04-01
... by reason of a change in place of employment, health, or unforeseen circumstances. If a safe harbor described in this section applies, a sale or exchange is deemed to be by reason of a change in place of... sale or exchange is by reason of a change in place of employment, health, or unforeseen circumstances...
Securing Cyberspace: Approaches to Developing an Effective Cyber-Security Strategy
2011-05-15
attackers, cyber - criminals or even teenage hackers. Protecting cyberspace is a national security priority. President Obama’s National Security...prefers to engage international law enforcement to investigate and catch cyber criminals .40 International cooperation could resolve jurisdictional...sheltered them. Similarly, a state that fails to prosecute cyber - criminals , or who gives safe haven to individuals or groups that conduct cyber-attacks
Snowmobiling in the 1980's: continued progress for a mature recreational activity
William T., Jr. Jobe
1980-01-01
In less than two decades, snowmobiling has changed from a novelty to a way of life for some 20,000,000 Canadian and American citizens of all ages. Why has snowmobiling continued to mushroom? Why did the challenges of inadequate safe use areas, public criticism and skepticism and primitive machines fail to doom the activity to a passing fad?
ERIC Educational Resources Information Center
Cornwall, Susannah
2018-01-01
Students increasingly appear anxious, risk-averse, and worried about getting things "wrong." They may appear to lack intellectual curiosity, and be unwilling to engage in independent study. This essay explores how teaching and assessment in theology and religious studies might help students learn to take intellectual risks, and increase…
Electronic switches and control circuits: A compilation
NASA Technical Reports Server (NTRS)
1971-01-01
The innovations in this updated series of compilations dealing with electronic technology represents a carefully selected collection of items on electronic switches and control circuits. Most of the items are based on well-known circuit design concepts that have been simplified or refined to meet NASA's demanding requirement for reliability, simplicity, fail-safe characteristics, and the capability of withstanding environmental extremes.
Optical Amplifier Based Space Solar Power
NASA Technical Reports Server (NTRS)
Fork, Richard L.
2001-01-01
The objective was to design a safe optical power beaming system for use in space. Research was focused on identification of strategies and structures that would enable achievement near diffraction limited optical beam quality, highly efficient electrical to optical conversion, and high average power in combination in a single system. Efforts centered on producing high efficiency, low mass of the overall system, low operating temperature, precision pointing and tracking capability, compatibility with useful satellite orbits, component and system reliability, and long component and system life in space. A system based on increasing the power handled by each individual module to an optimum and the number of modules in the complete structure was planned. We were concerned with identifying the most economical and rapid path to commercially viable safe space solar power.
Fail-Safe System against Potential Tumorigenicity after Transplantation of iPSC Derivatives.
Itakura, Go; Kawabata, Soya; Ando, Miki; Nishiyama, Yuichiro; Sugai, Keiko; Ozaki, Masahiro; Iida, Tsuyoshi; Ookubo, Toshiki; Kojima, Kota; Kashiwagi, Rei; Yasutake, Kaori; Nakauchi, Hiromitsu; Miyoshi, Hiroyuki; Nagoshi, Narihito; Kohyama, Jun; Iwanami, Akio; Matsumoto, Morio; Nakamura, Masaya; Okano, Hideyuki
2017-03-14
Human induced pluripotent stem cells (iPSCs) are promising in regenerative medicine. However, the risks of teratoma formation and the overgrowth of the transplanted cells continue to be major hurdles that must be overcome. Here, we examined the efficacy of the inducible caspase-9 (iCaspase9) gene as a fail-safe against undesired tumorigenic transformation of iPSC-derived somatic cells. We used a lentiviral vector to transduce iCaspase9 into two iPSC lines and assessed its efficacy in vitro and in vivo. In vitro, the iCaspase9 system induced apoptosis in approximately 95% of both iPSCs and iPSC-derived neural stem/progenitor cells (iPSC-NS/PCs). To determine in vivo function, we transplanted iPSC-NS/PCs into the injured spinal cord of NOD/SCID mice. All transplanted cells whose mass effect was hindering motor function recovery were ablated upon transduction of iCaspase9. Our results suggest that the iCaspase9 system may serve as an important countermeasure against post-transplantation adverse events in stem cell transplant therapies. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.
Tiffin, Norman H; Short, Kathy A; Jones, Samuel W; Cairns, Bruce A
2011-01-01
The VDR-4® high-frequency percussive ventilator (HFPV) has been shown to be beneficial in the management of inhalation injury by improving secretion clearance while maintaining oxygenation and ventilation. Delivery of gas flow during HFPV could lack adequate humidification delivered to the patient because a major portion of the delivered gas flow would bypass the humidifier when using the original VDR-4® ventilator circuit. The authors tested a novel inline vaporizing humidifier and two gas-water interface humidifiers during HFPV using the new VDR-4® Fail-safe Breathing Circuit Hub® to determine whether delivered humidification could be improved. This new humidification system, the Hydrate Omni™, delivers water vapor into the gas flow of the ventilator circuit rather than water droplets as delivered by the gas-water interface humidifiers. Measurements of absolute humidity and gas temperature were made on the three different humidification systems using a test lung model under standard ambient conditions. The authors found that when using the novel inline vaporizer, it provided better humidification when compared with the standard gas-water interface humidifier during HFPV using the new VDR-4® breathing circuit.
Code of Federal Regulations, 2010 CFR
2010-07-01
... using electrically released brakes shall be constructed so that the brakes cannot be released until power is applied, and so that the brakes are automatically engaged if the power fails or the operating... the operation of any power conveyor requires personnel to work in the immediate vicinity of the...
14 CFR 136.1 - Applicability and definitions.
Code of Federal Regulations, 2012 CFR
2012-01-01
... (powered or un-powered), parachutes (powered or un-powered), gyroplanes, or airships. (d) For the purposes... site-specific areas would provide an emergency landing area for a single-engine helicopter or a multiengine helicopter that does not have the capability to reach a safe landing area after an engine power...
14 CFR 136.1 - Applicability and definitions.
Code of Federal Regulations, 2014 CFR
2014-01-01
... (powered or un-powered), parachutes (powered or un-powered), gyroplanes, or airships. (d) For the purposes... site-specific areas would provide an emergency landing area for a single-engine helicopter or a multiengine helicopter that does not have the capability to reach a safe landing area after an engine power...
14 CFR 136.1 - Applicability and definitions.
Code of Federal Regulations, 2011 CFR
2011-01-01
... (powered or un-powered), parachutes (powered or un-powered), gyroplanes, or airships. (d) For the purposes... site-specific areas would provide an emergency landing area for a single-engine helicopter or a multiengine helicopter that does not have the capability to reach a safe landing area after an engine power...
14 CFR 136.1 - Applicability and definitions.
Code of Federal Regulations, 2010 CFR
2010-01-01
... (powered or un-powered), parachutes (powered or un-powered), gyroplanes, or airships. (d) For the purposes... site-specific areas would provide an emergency landing area for a single-engine helicopter or a multiengine helicopter that does not have the capability to reach a safe landing area after an engine power...
14 CFR 136.1 - Applicability and definitions.
Code of Federal Regulations, 2013 CFR
2013-01-01
... (powered or un-powered), parachutes (powered or un-powered), gyroplanes, or airships. (d) For the purposes... site-specific areas would provide an emergency landing area for a single-engine helicopter or a multiengine helicopter that does not have the capability to reach a safe landing area after an engine power...
The design and implementation of on-line monitoring system for UHV compact shunt capacitors
NASA Astrophysics Data System (ADS)
Tao, Weiliang; Ni, Xuefeng; Lin, Hao; Jiang, Shengbao
2017-08-01
Because of the large capacity and compact structure of the UHV compact shunt capacitor, it is difficult to take effective measures to detect and prevent the faults. If the fault capacitor fails to take timely maintenance, it will pose a threat to the safe operation of the system and the life safety of the maintenance personnel. The development of UHV compact shunt capacitor on-line monitoring system can detect and record the on-line operation information of UHV compact shunt capacitors, analyze and evaluate the early fault warning signs, find out the fault capacitor or the capacitor with fault symptom, to ensure safe and reliable operation of the system.
Holocamera for 3-D micrography of the alert human eye
NASA Astrophysics Data System (ADS)
Tokuda, A. R.; Auth, D. C.; Bruckner, A. P.
1980-07-01
A holocamera that safely records holograms of the full depth of the alert human eye with a spatial resolution of about 20 microns is described. A single-mode argon-ion laser generating 2 W at 5145 A serves as the illuminating source. Holographic exposure times of 0.3 msec are achieved by means of a fail-safe electromechanical shutter system. Integrated retinal irradiance levels are well under the American National Standards Institute safety standards. Reconstructed real images are projected directly onto the vidicon faceplate of a closed-circuit TV system, enabling convenient scanning in the x-y-z dimensions of the reconstructed eyeball. Serially reconstructed holograms of cataractous rabbit eyes and normal human eyes are presented.
Safe and rapid resolution of severe hypertriglyceridaemia in two patients with intravenous insulin.
Triay, J M; Day, A; Singhal, P
2010-09-01
To rapidly reduce serum triglyceride to a safe serum level. Severe hypertriglyceridaemia is associated with uncontrolled diabetes, obesity and poor physical activity. Even moderate increases in triglyceride levels (> 5mmol/L) confer an increased risk of pancreatitis and coronary artery disease. We present two patients with diabetes and serum triglyceride levels of greater than 85mmol/L despite polypharmacy intervention. 72-hour intravenous insulin infusion was administered. Serum triglyceride levels fell to 9.4 and 4.6 mmol/L respectively, without adverse events and sustained effect over several months. We suggest the use of intravenous insulin infusion where lifestyle and oral drug therapies have failed can impact on severe hypertriglyceridaemia.
77 FR 24364 - Airworthiness Directives; Bombardier, Inc. Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-24
... fatigue. Broken transformer primary winding can prevent the supply of power from the ADG to the essential...) airplanes. This AD was prompted by reports of the air driven generator (ADG) failing to power essential... generator control unit (GCU) preventing the ADG from supplying power to the essential buses. This AD...
33 CFR 150.607 - What are the general safe working requirements?
Code of Federal Regulations, 2012 CFR
2012-07-01
... machinery, cranes, derricks, portable power tools, and, most importantly, safety gear must be used in a safe... subchapter. (b) All machinery and equipment must be maintained in proper working order or removed. Personal...
33 CFR 150.607 - What are the general safe working requirements?
Code of Federal Regulations, 2013 CFR
2013-07-01
... machinery, cranes, derricks, portable power tools, and, most importantly, safety gear must be used in a safe... subchapter. (b) All machinery and equipment must be maintained in proper working order or removed. Personal...
33 CFR 150.607 - What are the general safe working requirements?
Code of Federal Regulations, 2014 CFR
2014-07-01
... machinery, cranes, derricks, portable power tools, and, most importantly, safety gear must be used in a safe... subchapter. (b) All machinery and equipment must be maintained in proper working order or removed. Personal...
Code of Federal Regulations, 2011 CFR
2011-07-01
... simultaneous use of the ramp by vehicles and pedestrians. (d) Ramp maintenance. Ramps shall be properly... ramp inclines safely. (j) Safe speeds. Power driven vehicles used in Ro-Ro operations shall be operated at speeds that are safe for prevailing conditions. (k) Ventilation. Internal combustion engine-driven...
van Netten, Jaap J; Georgiadis, Janniko R; Nieuwenburg, Arie; Kortekaas, Rudie
2008-04-01
Orgasm is a subjective experience accompanied by involuntary muscle contractions. We hypothesized that orgasm in women would be distinguishable by frequency analysis of a perineal muscle-derived signal. Rectal pressure, an index of perineal muscle activity, was measured continuously in 23 healthy women during different sexual tasks: receiving clitoral stimulation, imitation of orgasm, and attempt to reach orgasm, in which case the women were asked to report whether orgasm had been reached ("orgasm") or not ("failed orgasm attempt"). We performed spectral analysis on the rectal pressure data and calculated the spectral power in the frequency bands delta (0.5-4 Hz), theta (4-8 Hz), alpha (8-13 Hz), and beta (13-25 Hz). The most significant and most important difference in spectral power between orgasm and both control motor tasks (imitation of orgasm and failed orgasm attempt) was found in the alpha band. An objective rule based on spectral power in the alpha band recognized 94% (29/31) of orgasms and correctly labeled 69% (44/64) of all orgasm attempts as either successful or failed. Because outbursts of alpha fluctuations in rectal pressure only occurred during orgasm and not during voluntary imitation of orgasm or failed attempts, we propose that they represent involuntary contractions of muscles in the rectal vicinity. This is the first objective and quantitative measure that has a strong correspondence with the subjective experience of orgasm.
NASA Technical Reports Server (NTRS)
Trawny, Nikolas; Huertas, Andres; Luna, Michael E.; Villalpando, Carlos Y.; Martin, Keith E.; Carson, John M.; Johnson, Andrew E.; Restrepo, Carolina; Roback, Vincent E.
2015-01-01
The Hazard Detection System (HDS) is a component of the ALHAT (Autonomous Landing and Hazard Avoidance Technology) sensor suite, which together provide a lander Guidance, Navigation and Control (GN&C) system with the relevant measurements necessary to enable safe precision landing under any lighting conditions. The HDS consists of a stand-alone compute element (CE), an Inertial Measurement Unit (IMU), and a gimbaled flash LIDAR sensor that are used, in real-time, to generate a Digital Elevation Map (DEM) of the landing terrain, detect candidate safe landing sites for the vehicle through Hazard Detection (HD), and generate hazard-relative navigation (HRN) measurements used for safe precision landing. Following an extensive ground and helicopter test campaign, ALHAT was integrated onto the Morpheus rocket-powered terrestrial test vehicle in March 2014. Morpheus and ALHAT then performed five successful free flights at the simulated lunar hazard field constructed at the Shuttle Landing Facility (SLF) at Kennedy Space Center, for the first time testing the full system on a lunar-like approach geometry in a relevant dynamic environment. During these flights, the HDS successfully generated DEMs, correctly identified safe landing sites and provided HRN measurements to the vehicle, marking the first autonomous landing of a NASA rocket-powered vehicle in hazardous terrain. This paper provides a brief overview of the HDS architecture and describes its in-flight performance.
Rep. Kucinich, Dennis J. [D-OH-10
2010-07-22
House - 07/27/2010 On agreeing to the resolution Failed by the Yeas and Nays: 38 - 372, 4 Present (Roll no. 473). (All Actions) Tracker: This bill has the status Failed HouseHere are the steps for Status of Legislation:
Performance testing of collision-avoidance system for power wheelchairs.
Lopresti, Edmund F; Sharma, Vinod; Simpson, Richard C; Mostowy, L Casimir
2011-01-01
The Drive-Safe System (DSS) is a collision-avoidance system for power wheelchairs designed to support people with mobility impairments who also have visual, upper-limb, or cognitive impairments. The DSS uses a distributed approach to provide an add-on, shared-control, navigation-assistance solution. In this project, the DSS was tested for engineering goals such as sensor coverage, maximum safe speed, maximum detection distance, and power consumption while the wheelchair was stationary or driven by an investigator. Results indicate that the DSS provided uniform, reliable sensor coverage around the wheelchair; detected obstacles as small as 3.2 mm at distances of at least 1.6 m; and attained a maximum safe speed of 4.2 km/h. The DSS can drive reliably as close as 15.2 cm from a wall, traverse doorways as narrow as 81.3 cm without interrupting forward movement, and reduce wheelchair battery life by only 3%. These results have implications for a practical system to support safe, independent mobility for veterans who acquire multiple disabilities during Active Duty or later in life. These tests indicate that a system utilizing relatively low cost ultrasound, infrared, and force sensors can effectively detect obstacles in the vicinity of a wheelchair.
47 CFR 74.710 - Digital low power TV and TV translator station protection.
Code of Federal Regulations, 2012 CFR
2012-10-01
... SERVICES Low Power TV, TV Translator, and TV Booster Stations § 74.710 Digital low power TV and TV... booster station or change the facilities of an existing station will not be accepted if it fails to... filed prior to the date the low power TV, TV translator, or TV booster application is filed. (b...
47 CFR 74.710 - Digital low power TV and TV translator station protection.
Code of Federal Regulations, 2011 CFR
2011-10-01
... SERVICES Low Power TV, TV Translator, and TV Booster Stations § 74.710 Digital low power TV and TV... booster station or change the facilities of an existing station will not be accepted if it fails to... filed prior to the date the low power TV, TV translator, or TV booster application is filed. (b...
47 CFR 74.710 - Digital low power TV and TV translator station protection.
Code of Federal Regulations, 2014 CFR
2014-10-01
... SERVICES Low Power TV, TV Translator, and TV Booster Stations § 74.710 Digital low power TV and TV... booster station or change the facilities of an existing station will not be accepted if it fails to... filed prior to the date the low power TV, TV translator, or TV booster application is filed. (b...
47 CFR 74.710 - Digital low power TV and TV translator station protection.
Code of Federal Regulations, 2013 CFR
2013-10-01
... SERVICES Low Power TV, TV Translator, and TV Booster Stations § 74.710 Digital low power TV and TV... booster station or change the facilities of an existing station will not be accepted if it fails to... filed prior to the date the low power TV, TV translator, or TV booster application is filed. (b...
Safe Affordable Fission Engine-(SAFE-) 100a Heat Exchanger Thermal and Structural Analysis
NASA Technical Reports Server (NTRS)
Steeve, B. E.
2005-01-01
A potential fission power system for in-space missions is a heat pipe-cooled reactor coupled to a Brayton cycle. In this system, a heat exchanger (HX) transfers the heat of the reactor core to the Brayton gas. The Safe Affordable Fission Engine- (SAFE-) 100a is a test program designed to thermally and hydraulically simulate a 95 Btu/s prototypic heat pipe-cooled reactor using electrical resistance heaters on the ground. This Technical Memorandum documents the thermal and structural assessment of the HX used in the SAFE-100a program.
Secure Embedded System Design Methodologies for Military Cryptographic Systems
2016-03-31
Fault- Tree Analysis (FTA); Built-In Self-Test (BIST) Introduction Secure access-control systems restrict operations to authorized users via methods...failures in the individual software/processor elements, the question of exactly how unlikely is difficult to answer. Fault- Tree Analysis (FTA) has a...Collins of Sandia National Laboratories for years of sharing his extensive knowledge of Fail-Safe Design Assurance and Fault- Tree Analysis
Stress Corrosion of Ceramic Materials
1981-10-01
stresses are liable to fail after an indeterminate period of time, leading to a considerable uncertainty in the safe design stress. One of the objectives...of modern ceramics technology is to reduce the uncertainty associated with structural design , and hence, to improve our capabilities of designing ...processes that occur during stress corrosion cracking. Recent advances in th~earea of structural design with ceramic materials have lead to several
Intranasal dexmedetomidine for sedation for pediatric computed tomography imaging.
Mekitarian Filho, Eduardo; Robinson, Fay; de Carvalho, Werther Brunow; Gilio, Alfredo Elias; Mason, Keira P
2015-05-01
This prospective observational pilot study evaluated the aerosolized intranasal route for dexmedetomidine as a safe, effective, and efficient option for infant and pediatric sedation for computed tomography imaging. The mean time to sedation was 13.4 minutes, with excellent image quality, no failed sedations, or significant adverse events. Registered with ClinicalTrials.gov: NCT01900405. Copyright © 2015 Elsevier Inc. All rights reserved.
Worcester 1 Inch Solenoid Actuated Gas Operated SCHe System Valves
DOE Office of Scientific and Technical Information (OSTI.GOV)
VAN KATWIJK, C.
1 inch Gas-operated full-port ball valves incorporate a solenoid and limit switches as integral parts of the actuator. These valves are normally open and fail safe to the open position (GOV-1*02 and 1*06 fall closed) to provide a flow path of helium gas to the MCO under helium purge and off-normal conditions when the MCO is isolated.
NASA Technical Reports Server (NTRS)
Jackson, A. C.; Dorwald, F.
1982-01-01
The ground tests conducted on the advanced composite vertical fin (ACVF) program are described. The design and fabrication of the test fixture and the transition structure, static test of Ground Test Article (GTA) No. 1, rework of GTA No. 2, and static, damage tolerance, fail-safe and residual strength tests of GTA No. 2 are described.
ERIC Educational Resources Information Center
Sinclair, Alison J.
2017-01-01
The ability to apply prior knowledge to new challenges is a skill that is highly valued by employers, but the confidence to achieve this does not come naturally to all students. An essential step to becoming an independent researcher requires a transition between simply following a fail-safe set of instructions to being able to adapt a known…
Korenstein, Deborah; Keyhani, Salomeh; Mendelson, Ali; Ross, Joseph S.
2011-01-01
Background Physician-directed pharmaceutical advertising is regulated in the United States by the Food and Drug Administration (FDA); adherence to current FDA guidelines is unknown. Our objective was to determine adherence rates of physician-directed print advertisements in biomedical journals to FDA guidelines and describe content important for safe prescribing. Methods and Findings Cross-sectional analysis of November 2008 pharmaceutical advertisements within top U.S.-based biomedical journals publishing original research. We excluded advertisements for devices, over the counter medications, and disease awareness. We utilized FDA guideline items identifying unique forms of advertisement bias to categorize advertisements as adherent to FDA guidelines, possibly non-adherent to at least 1 item, or non-adherent to at least 1 item. We also evaluated advertisement content important for safe prescribing, including benefit quantification, risk information and verifiable references. All advertisements were evaluated by 2 or more investigators, with differences resolved by discussion. Twelve journals met inclusion criteria. Nine contained pharmaceutical advertisements, including 192 advertisements for 82 unique products; median 2 per product (range 1–14). Six “teaser” advertisements presented only drug names, leaving 83 full unique advertisements. Fifteen advertisements (18.1%) adhered to all FDA guidelines, 41 (49.4%) were non-adherent with at least one form of FDA-described bias, and 27 (32.5%) were possibly non-adherent due to incomplete information. Content important for safe prescribing was often incomplete; 57.8% of advertisements did not quantify serious risks, 48.2% lacked verifiable references and 28.9% failed to present adequate efficacy quantification. Study limitations included its focus on advertisements from a single month, the subjectivity of FDA guidelines themselves, and the necessary subjectivity of determinations of adherence. Conclusions Few physician-directed print pharmaceutical advertisements adhere to all FDA guidelines; over half fail to quantify serious risks. The FDA could better protect public health by creating new more objective advertisement guidelines requiring transparent presentation of basic safety and efficacy information. PMID:21858076
Korenstein, Deborah; Keyhani, Salomeh; Mendelson, Ali; Ross, Joseph S
2011-01-01
Physician-directed pharmaceutical advertising is regulated in the United States by the Food and Drug Administration (FDA); adherence to current FDA guidelines is unknown. Our objective was to determine adherence rates of physician-directed print advertisements in biomedical journals to FDA guidelines and describe content important for safe prescribing. Cross-sectional analysis of November 2008 pharmaceutical advertisements within top U.S.-based biomedical journals publishing original research. We excluded advertisements for devices, over the counter medications, and disease awareness. We utilized FDA guideline items identifying unique forms of advertisement bias to categorize advertisements as adherent to FDA guidelines, possibly non-adherent to at least 1 item, or non-adherent to at least 1 item. We also evaluated advertisement content important for safe prescribing, including benefit quantification, risk information and verifiable references. All advertisements were evaluated by 2 or more investigators, with differences resolved by discussion. Twelve journals met inclusion criteria. Nine contained pharmaceutical advertisements, including 192 advertisements for 82 unique products; median 2 per product (range 1-14). Six "teaser" advertisements presented only drug names, leaving 83 full unique advertisements. Fifteen advertisements (18.1%) adhered to all FDA guidelines, 41 (49.4%) were non-adherent with at least one form of FDA-described bias, and 27 (32.5%) were possibly non-adherent due to incomplete information. Content important for safe prescribing was often incomplete; 57.8% of advertisements did not quantify serious risks, 48.2% lacked verifiable references and 28.9% failed to present adequate efficacy quantification. Study limitations included its focus on advertisements from a single month, the subjectivity of FDA guidelines themselves, and the necessary subjectivity of determinations of adherence. Few physician-directed print pharmaceutical advertisements adhere to all FDA guidelines; over half fail to quantify serious risks. The FDA could better protect public health by creating new more objective advertisement guidelines requiring transparent presentation of basic safety and efficacy information.
Evolution of shuttle avionics redundancy management/fault tolerance
NASA Technical Reports Server (NTRS)
Boykin, J. C.; Thibodeau, J. R.; Schneider, H. E.
1985-01-01
The challenge of providing redundancy management (RM) and fault tolerance to meet the Shuttle Program requirements of fail operational/fail safe for the avionics systems was complicated by the critical program constraints of weight, cost, and schedule. The basic and sometimes false effectivity of less than pure RM designs is addressed. Evolution of the multiple input selection filter (the heart of the RM function) is discussed with emphasis on the subtle interactions of the flight control system that were found to be potentially catastrophic. Several other general RM development problems are discussed, with particular emphasis on the inertial measurement unit RM, indicative of the complexity of managing that three string system and its critical interfaces with the guidance and control systems.
Anti-backlash drive systems for multi-degree freedom devices
Tsai, Lung-Wen; Chang, Sun-Lai
1993-01-01
A new and innovative concept for the control of backlash in gear-coupled transmission mechanisms. The concept utilizes redundant unidirectional drives to assure positive coupling of gear meshes at all times. Based on this concept, a methodology for the enumeration of admissible redundant-drive backlash-free robotic mechanisms has been established. Some typical two- and three-DOF mechanisms are disclosed. Furthermore, actuator torques have been derived as functions of either joint torques or end-effector dynamic performance requirements. A redundantly driven gear coupled transmission mechanism manipulator has a fail-safe advantage in that, except of the loss of backlash control, it can continue to function when one of its actuators fails. A two-DOF backlash-free arm has been reduced to practice to demonstrate the principle.
Safe-trajectory optimization and tracking control in ultra-close proximity to a failed satellite
NASA Astrophysics Data System (ADS)
Zhang, Jingrui; Chu, Xiaoyu; Zhang, Yao; Hu, Quan; Zhai, Guang; Li, Yanyan
2018-03-01
This paper presents a trajectory-optimization method for a chaser spacecraft operating in ultra-close proximity to a failed satellite. Based on the combination of active and passive trajectory protection, the constraints in the optimization framework are formulated for collision avoidance and successful docking in the presence of any thruster failure. The constraints are then handled by an adaptive Gauss pseudospectral method, in which the dynamic residuals are used as the metric to determine the distribution of collocation points. A finite-time feedback control is further employed in tracking the optimized trajectory. In particular, the stability and convergence of the controller are proved. Numerical results are given to demonstrate the effectiveness of the proposed methods.
76 FR 1416 - Combined Notice of Filings #1
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-10
... Wind Farm LLC; State Line Energy, LLC; Kincaid Generation, L.L.C.; Virginia Electric and Power Company...: Constellation Energy Commodities Group, R.E. Ginna Nuclear Power Plant, LLC, AES NewEnergy, Inc., Baltimore Gas..., Safe Harbor Water Power Corporation, Calvert Cliffs Nuclear Power Plant LLC, CER Generation, LLC...
29 CFR 1917.43 - Powered industrial trucks.
Code of Federal Regulations, 2012 CFR
2012-07-01
... safety. (5) Powered industrial trucks shall be marked with their rated capacities, which shall be visible.... (5) Powered industrial trucks shall be maintained in safe working order. Safety devices shall not be... 29 Labor 7 2012-07-01 2012-07-01 false Powered industrial trucks. 1917.43 Section 1917.43 Labor...
29 CFR 1917.43 - Powered industrial trucks.
Code of Federal Regulations, 2014 CFR
2014-07-01
... safety. (5) Powered industrial trucks shall be marked with their rated capacities, which shall be visible.... (5) Powered industrial trucks shall be maintained in safe working order. Safety devices shall not be... 29 Labor 7 2014-07-01 2014-07-01 false Powered industrial trucks. 1917.43 Section 1917.43 Labor...
Inherently Safe Fission Power System for Lunar Outposts
NASA Astrophysics Data System (ADS)
Schriener, Timothy M.; El-Genk, Mohamed S.
2013-09-01
This paper presents the Solid Core-Sectored Compact Reactor (SC-SCoRe) and power system for future lunar outposts. The power system nominally provides 38 kWe continuously for 21 years, employs static components and has no single point failures in reactor cooling or power generation. The reactor core has six sectors, each has a separate pair of primary and secondary loops with liquid NaK-56 working fluid, thermoelectric (TE) power conversion and heat-pipes radiator panels. The electromagnetic (EM) pumps in the primary and secondary loops, powered with separate TE power units, ensure operation reliability and passive decay heat removal from the reactor after shutdown. The reactor poses no radiological concerns during launch, and remains sufficiently subcritical, with the radial reflector dissembled, when submerged in wet sand and the core flooded with seawater, following a launch abort accident. After 300 years of storage below grade on the Moon, the total radioactivity in the post-operation reactor drops below 164 Ci, a low enough radioactivity for a recovery and safe handling of the reactor.
NASA Technical Reports Server (NTRS)
Fork, Richard L.
2001-01-01
The objective was to assess the feasibility of safely collecting solar power at geostationary orbit and delivering it to earth. A strategy which could harness a small fraction of the millions of gigawatts of sunlight passing near earth could adequately supply the power needs of earth and those of space exploration far into the future. Light collected and enhanced both spatially and temporally in space and beamed to earth provides probably the only practical means of safe and efficient delivery of this space solar power to earth. In particular, we analyzed the feasibility of delivering power to sites on earth at a comparable intensity, after conversion to a usable form, to existing power needs. Two major obstacles in the delivery of space solar power to earth are safety and the development of a source suitable for space. We focused our approach on: (1) identifying system requirements and designing a strategy satisfying current eye and skin safety requirements; and (2) identifying a concept for a potential space-based source for producing the enhanced light.
Wen, Jun; Duan, Chuan-Zhi; Huang, Li-Jing; Zhang, Xin; He, Xu-Ying; Li, Xi-Feng
2015-09-01
Transvenous embolization is the treatment of choice for cavernous sinus dural arteriovenous fistulas (csDAVFs) despite occasional difficulty in transvenous catheterization. We reported our experience in the treatment of csDAVFs by transarterial Onyx embolization in patients who had failed transvenous catheterization. We reviewed the clinical and radiographic records of csDAVFs patients receiving transarterial Onyx embolization after failed transvenous Onyx embolization at our institution over a period of 31 months. Success was defined as complete or near complete occlusion upon angiographic examination. In seven cases, the microcatheter failed to reach the cavernous sinus; in the remaining case, the internal jugular vein was occlusive. Eight sessions of the embolization and catheterization procedures via the arterial routes were conducted. Among them, five cases via the middle meningeal artery and the other three via the accessory meningeal artery. Angiography, immediately after embolization, revealed complete occlusion in seven cases (87.5 %) and partial occlusion in the remaining case. Angiographic follow-up (range, 6-10 months) showed that all patients achieved complete embolization. In cases where transvenous embolization of the cavernous sinus is difficult, transarterial embolization of the fistulas offers a safe and effective alternative.
Houliston, Bryan; Parry, David; Webster, Craig S; Merry, Alan F
2009-06-19
To replicate electromagnetic interference (EMI) with a common drug infusion device resulting from the use of radio frequency identification (RFID) technology in a simulated operating theatre environment. An infusion pump, of a type previously reported as having failed due to RFID EMI, was placed in radio frequency (RF) fields of various strengths, and its operation observed. Different strength RF fields were created by varying the number of RFID readers, the use of a high-gain RFID antenna, the distance between the reader(s) and the infusion pump, and the presence of an RFID tag on the infusion pump. The infusion pump was not affected by low-power RFID readers, even when in direct contact. The pump was disrupted by a high-power reader at 10 cm distance when an RFID tag was attached, and by a combination of high-power and low-power readers at 10 cm distance. Electronic medical devices may fail in the presence of high-power RFID readers, especially if the device is tagged. However, low-power RFID readers appear to be safer.
Phillips removes Failed RPCM (Remote Power Controller Module)
2005-09-20
ISS011-E-13361 (20 September 2005) --- Astronaut John L. Phillips, Expedition 11 NASA science officer and flight engineer, performs a Remote Power Control Module (RPCM) remove and replacement in the Unity node of the international space station.
Inherently Safe and Long-Life Fission Power System for Lunar Outposts
NASA Astrophysics Data System (ADS)
Schriener, T. M.; El-Genk, Mohamed S.
Power requirements for future lunar outposts, of 10's to 100's kWe, can be fulfilled using nuclear reactor power systems. In addition to the long life and operation reliability, safety is paramount in all phases, including fabrication and assembly, launch, emplacement below grade on the lunar surface, operation, post-operation decay heat removal and long-term storage and eventual retrieval. This paper introduces the Solid Core-Sectored Compact Reactor (SC-SCoRe) and power system with static components and no single point failures. They ensure reliable continuous operation for ~21 years and fulfill the safety requirements. The SC-SCoRe nominally generates 1.0 MWth at liquid NaK-56 coolant inlet and exit temperatures of 850 K and 900 K and the power system provides 38 kWe at high DC voltage using SiGe thermoelectric (TE) conversion assemblies. In case of a loss of coolant or cooling in a reactor core sector, the power system continues to operate; generating ~4 kWe to the outpost for emergency life support needs. The post-operation storage of the reactor below grade on the lunar surface is a safe and practical choice. The total radioactivity in the reactor drops from ~1 million Ci, immediately at shutdown, to below 164 Ci after 300 years of storage. At such time, the reactor is retrieved safely with no contamination or environmental concerns.
Differential effects of ongoing EEG beta and theta power on memory formation
Scholz, Sebastian; Schneider, Signe Luisa
2017-01-01
Recently, elevated ongoing pre-stimulus beta power (13–17 Hz) at encoding has been associated with subsequent memory formation for visual stimulus material. It is unclear whether this activity is merely specific to visual processing or whether it reflects a state facilitating general memory formation, independent of stimulus modality. To answer that question, the present study investigated the relationship between neural pre-stimulus oscillations and verbal memory formation in different sensory modalities. For that purpose, a within-subject design was employed to explore differences between successful and failed memory formation in the visual and auditory modality. Furthermore, associative memory was addressed by presenting the stimuli in combination with background images. Results revealed that similar EEG activity in the low beta frequency range (13–17 Hz) is associated with subsequent memory success, independent of stimulus modality. Elevated power prior to stimulus onset differentiated successful from failed memory formation. In contrast, differential effects between modalities were found in the theta band (3–7 Hz), with an increased oscillatory activity before the onset of later remembered visually presented words. In addition, pre-stimulus theta power dissociated between successful and failed encoding of associated context, independent of the stimulus modality of the item itself. We therefore suggest that increased ongoing low beta activity reflects a memory promoting state, which is likely to be moderated by modality-independent attentional or inhibitory processes, whereas high ongoing theta power is suggested as an indicator of the enhanced binding of incoming interlinked information. PMID:28192459
Sharma, Vinod; Simpson, Richard; Lopresti, Edmund; Schmeler, Mark
2010-01-01
Some individuals with disabilities are denied powered mobility because they lack the visual, motor, and/or cognitive skills required to safely operate a power wheelchair. The Drive-Safe System (DSS) is an add-on, distributed, shared-control navigation assistance system for power wheelchairs intended to provide safe and independent mobility to such individuals. The DSS is a human-machine system in which the user is responsible for high-level control of the wheelchair, such as choosing the destination, path planning, and basic navigation actions, while the DSS overrides unsafe maneuvers through autonomous collision avoidance, wall following, and door crossing. In this project, the DSS was clinically evaluated in a controlled laboratory with blindfolded, nondisabled individuals. Further, these individuals' performance with the DSS was compared with standard cane use for navigation assistance by people with visual impairments. Results indicate that compared with a cane, the DSS significantly reduced the number of collisions. Users rated the DSS favorably even though they took longer to navigate the same obstacle course than they would have using a standard long cane. Participants experienced less physical demand, effort, and frustration when using the DSS as compared with a cane. These findings suggest that the DSS can be a viable powered mobility solution for wheelchair users with visual impairments.
76 FR 7555 - Combined Notice of Filings #2
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-10
...Energy, Inc., CER Generation II, LLC, Safe Harbor Water Power Corporation, Handsome Lake Energy, LLC, Constellation Energy Commodities Group M, CER Generation, LLC, Criterion Power Partners, LLC. Description...
DOE Office of Scientific and Technical Information (OSTI.GOV)
None, None
NNSA’s third mission pillar is supporting the U.S. Navy’s ability to protect and defend American interests across the globe. The Naval Reactors Program remains at the forefront of technological developments in naval nuclear propulsion and ensures a commanding edge in warfighting capabilities by advancing new technologies and improvements in naval reactor performance and reliability. In 2015, the Naval Nuclear Propulsion Program pioneered advances in nuclear reactor and warship design – such as increasing reactor lifetimes, improving submarine operational effectiveness, and reducing propulsion plant crewing. The Naval Reactors Program continued its record of operational excellence by providing the technical expertise requiredmore » to resolve emergent issues in the Nation’s nuclear-powered fleet, enabling the Fleet to safely steam more than two million miles. Naval Reactors safely maintains, operates, and oversees the reactors on the Navy’s 82 nuclear-powered warships, constituting more than 45 percent of the Navy’s major combatants.« less
Laser beamed power: Satellite demonstration applications
NASA Technical Reports Server (NTRS)
Landis, Geoffrey A.; Westerlund, Larry H.
1992-01-01
It is possible to use a ground-based laser to beam light to the solar arrays of orbiting satellites, to a level sufficient to provide all or some of the operating power required. Near-term applications of this technology for providing supplemental power to existing satellites are discussed. Two missions with significant commercial pay-off are supplementing solar power for radiation-degraded arrays and providing satellite power during eclipse for satellites with failed batteries.
Management of post-traumatic elbow instability after failed radial head excision: A case report.
Touloupakis, Georgios; Theodorakis, Emmanouil; Favetti, Fabio; Nannerini, Massimiliano
2017-02-01
Radial head excision has always been a safe commonly used surgical procedure with a satisfactory clinical outcome for isolated comminuted radial head fractures. However, diagnosis of elbow instability is still very challenging and often underestimated in routine orthopaedic evaluation. We present the case of a 21-years old female treated with excision after radial head fracture, resulting in elbow instability. The patient underwent revision surgery after four weeks. We believe that ligament reconstruction without radial head substitution is a safe alternative choice for Mason III radial head fractures accompanied by complex ligament lesions. Copyright © 2017 Daping Hospital and the Research Institute of Surgery of the Third Military Medical University. Production and hosting by Elsevier B.V. All rights reserved.
49 CFR 393.23 - Power supply for lamps.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 5 2013-10-01 2013-10-01 false Power supply for lamps. 393.23 Section 393.23... NECESSARY FOR SAFE OPERATION Lamps, Reflective Devices, and Electrical Wiring § 393.23 Power supply for lamps. All required lamps must be powered by the electrical system of the motor vehicle with the...
49 CFR 393.23 - Power supply for lamps.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 5 2012-10-01 2012-10-01 false Power supply for lamps. 393.23 Section 393.23... NECESSARY FOR SAFE OPERATION Lamps, Reflective Devices, and Electrical Wiring § 393.23 Power supply for lamps. All required lamps must be powered by the electrical system of the motor vehicle with the...
Results of 30 kWt Safe Affordable Fission Engine (SAFE-30) primary heat transport testing
NASA Astrophysics Data System (ADS)
Pedersen, Kevin; van Dyke, Melissa; Houts, Mike; Godfroy, Tom; Martin, James; Dickens, Ricky; Williams, Eric; Harper, Roger; Salvil, Pat; Reid, Bob
2001-02-01
The use of resistance heaters to simulate heat from fission allows extensive development of fission systems to be performed in non-nuclear test facilities, saving time and money. Resistance heated tests on the Safe Affordable Fission Engine-30 kilowatt (SAFE30) test article are being performed at the Marshall Space Flight Center. This paper discusses the results of these experiments to date, and describes the additional testing that will be performed. Recommendations related to the design of testable space fission power and propulsion systems are made. .
Carter, Reagan, and Congress: The Changing Dynamics of Security Assistance and Arms Sales
1991-01-01
only enumerated power given to the President in the Constitution is the title of Commander-in-Chief of the armed forces. As part of the separation of powers , Congress...constitutional separation of powers and the law was struck down on the grounds that this type of resolution fails the test of presentment to the
Models of Power and the Deletion of Participation in a Classroom Literacy Event
ERIC Educational Resources Information Center
Jacobs, Gloria E.
2012-01-01
This article uses the analytic lens of power relations and models of power to examine how the participation of two students in an urban US eighth-grade English language arts class was symbolically and literally deleted. The researcher asks why do some students fail despite being placed in a technologically rich educational environment that…
Power Factors that Define Gender Inequity within the Missouri Public School Superintendency
ERIC Educational Resources Information Center
Alexander, Kristina; Grispino, Frank D.; Messner, Phillip E.
2004-01-01
Although women have access to the superintendency power position, evidence has shown that women have not been able to consistently break the glass ceiling. A review of related literature failed to identify specific and practical employment factors that must be resolved or overcome if women are to reach power parity in Missouri. This study was…
CHEMICAL RIGIDIZATION OF EXPANDABLE STRUCTURES.
The objective of this program was to develop a chemical rigidization process that could be activated by an on-command mechanism and be capable of...and rigidized in the high vacuum facilities atWright-Patterson AFB, Ohio and were delivered to the Air Force. A fail-safe chemical rigidization system...have been varied from fifteen minutes to two hours. The chemical system, a vinyl-type monomer, has exhibited a sustained shelf-life, under ambient
Efficiently, Effectively Detecting Mobile App Bugs with AppDoctor
2014-04-01
1 ∼ 5 ACV Comic Viewer 2 1 ∼ 5 Yes OpenSudoku 1 1 ∼ 5 Yes OI Notepad 1 0.1 ∼ 0.5 Yes OI Safe 1 0.1 ∼ 0.5 Yes Table 1: Each app’s bug count. First row... Comic Viewer Incorrect assumption of the presence of Google Services caused a crash Reported 6 ACV Comic Viewer Failed to check for the failure of
FAIL-SAFE: Fault Aware IntelLigent Software for Exascale
2016-06-13
and that these programs can continue to correct solutions. To broaden the impact of this research, we also needed to be able to ameliorate errors...designing an interface between the application and an introspection framework for resilience ( IFR ) based on the inference engine SHINE; (4) using...the ROSE compiler to translate annotations into reasoning rules for the IFR ; and (5) designing a Knowledge/Experience Database, which will store
Rational use of analgesic combinations.
Phero, James C; Becker, Daniel
2002-10-01
Careful selection of an effective analgesic regimen based on the amount and type of pain the patient is expected to have can prevent the stress and anxiety associated with breakthrough pain. When analgesics fail, it is not unusual for patients to go to desperate lengths to seek relief. The clinician can and should develop a variety of effective, safe analgesic regimens based on estimates of anticipated pain intensity that apply sound pharmacologic principles.
ERIC Educational Resources Information Center
Meghani, Zahra; de Melo-Martin, Inmaculada
2009-01-01
The U.S. Food and Drug Administration (FDA) announced recently that food products derived from some animal clones and their offspring are safe for human consumption. In response to criticism that it had failed to engage with ethical, social, and economic concerns raised by livestock cloning, the FDA argued that addressing normative issues prior to…
An Approach to Forward Presence in a Resource-Constrained Environment
2013-03-01
working quietly to coordinate cooperation between Indonesia, Malaysia , and Singapore , who were historically distrustful of each other. Through...freedom of action. Non-state actors will likely seek to capitalize on these weakening and corrupt failing states as potential safe havens. The low...11 Figure 1. 2011 Defense Spending: United States vs . 16 Next Leading Spenders44 Department of Defense can feel like it is hard pressed for
Code of Federal Regulations, 2010 CFR
2010-04-01
... required under this part, the appropriate TTB officer may withdraw the person's right to use the safe... officer may also require a taxpayer who fails to make deposits of tax to file a monthly or semimonthly...-25, each deposit required to be made by this section shall be made not later than the 9th day of the...
Fail-Safe Design for Large Capacity Lithium-Ion Battery Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, G. H.; Smith, K.; Ireland, J.
2012-07-15
A fault leading to a thermal runaway in a lithium-ion battery is believed to grow over time from a latent defect. Significant efforts have been made to detect lithium-ion battery safety faults to proactively facilitate actions minimizing subsequent losses. Scaling up a battery greatly changes the thermal and electrical signals of a system developing a defect and its consequent behaviors during fault evolution. In a large-capacity system such as a battery for an electric vehicle, detecting a fault signal and confining the fault locally in the system are extremely challenging. This paper introduces a fail-safe design methodology for large-capacity lithium-ionmore » battery systems. Analysis using an internal short circuit response model for multi-cell packs is presented that demonstrates the viability of the proposed concept for various design parameters and operating conditions. Locating a faulty cell in a multiple-cell module and determining the status of the fault's evolution can be achieved using signals easily measured from the electric terminals of the module. A methodology is introduced for electrical isolation of a faulty cell from the healthy cells in a system to prevent further electrical energy feed into the fault. Experimental demonstration is presented supporting the model results.« less
Effects of foot reflexology on fatigue, sleep and pain: a systematic review and meta-analysis.
Lee, Jeongsoon; Han, Misook; Chung, Younghae; Kim, Jinsun; Choi, Jungsook
2011-12-01
The purpose of this study was to evaluate the effectiveness of foot reflexology on fatigue, sleep and pain. A systematic review and meta-analysis were conducted. Electronic database and manual searches were conducted on all published studies reporting the effects of foot reflexology on fatigue, sleep, and pain. Forty four studies were eligible including 15 studies associated with fatigue, 18 with sleep, and 11 with pain. The effects of foot reflexology were analyzed using Comprehensive Meta-Analysis Version 2.0. The homogeneity and the fail-safe N were calculated. Moreover, a funnel plot was used to assess publication bias. The effects on fatigue, sleep, and pain were not homogeneous and ranged from 0.63 to 5.29, 0.01 to 3.22, and 0.43 to 2.67, respectively. The weighted averages for fatigue, sleep, and pain were 1.43, 1.19, and 1.35, respectively. No publication bias was detected as evaluated by fail-safe N. Foot reflexology had a larger effect on fatigue and sleep and a smaller effect on pain. This meta-analysis indicates that foot reflexology is a useful nursing intervention to relieve fatigue and to promote sleep. Further studies are needed to evaluate the effects of foot reflexology on outcome variables other than fatigue, sleep and pain.
[Use of Gastrografin(®) in the management of adhesion intestinal obstruction].
Mora López, Laura; Serra-Aracil, Xavier; Llaquet Bayo, Heura; Navarro Soto, Salvador
2013-01-01
Adhesions are the most important cause of intestinal obstruction. Approximately 25% of surgical admissions for acute abdominal conditions are due to intestinal obstruction. Better diagnostic and treatment methods of intestinal obstruction could potentially reduce mortality rate to 5-10%. Gastrografin(®) could contribute to this achieve this. To present a protocol to treat adhesion intestinal obstruction with Gastrografin(®) that is safe, and allows shorter hospital stays and shorter time between admission and surgery. All patients with adhesion intestinal obstruction without symptoms of strangulation were treated with Gastrografin(®), intravenous fluids and nasogastric tube. Those in whom contrast reach the colon in 8, 12 or 24hours were considered to have partial obstruction, and were fed orally. If Gastrografin(®) failed in the following 24hours, a laparotomy was performed. Out of a total of 211 episodes (164 patients), 170 episodes received contrast and in 142 cases Gastrografin(®) reached the colon (104 episodes at 8h, 11 at 12h, and 27 at 24h). A laparotomy was required in 28 patients because of failed treatment, and in another 5 for other causes. A management protocol for adhesion intestinal obstruction with Gastrografin(®) is safe, reduces morbidity and mortality, and leads to a shorter hospital stay. Copyright © 2012 AEC. Published by Elsevier Espana. All rights reserved.
Quaranta, Luciano; Floriani, Irene; Hollander, Lital; Poli, Davide; Katsanos, Andreas; Konstas, Anastasios G P
2016-04-01
To determine the outcome of needling with adjunctive 5-fluorouracil (5-FU) in patients with a failing Ahmed glaucoma valve (AGV) implant, and to identify predictors of long-term intraocular pressure (IOP) control. A prospective observational study was performed on consecutive patients with medically uncontrolled primary open-angle glaucoma (POAG) with AGV encapsulation or fibrosis and inadequate IOP control. Bleb needling with 5-FU injection (0.1 mL of 50 mg/mL) was performed at the slit-lamp. Patients were examined 1 week following the needling, and then at months 1, 3, and 6. Subsequent follow-up visits were scheduled at 6-month intervals for at least 2 years. Needling with 5-FU was repeated no more than twice during the first 3 months of the follow-up. Procedure outcome was determined on the basis of the recorded IOP levels. Thirty-six patients with an encapsulated or fibrotic AGV underwent 67procedures (mean 1.86 ± 0.83). Complete success, defined as IOP ≤ 18 mm Hg without medications, was obtained in 25% at 24 months of observation. The cumulative proportion of cases achieving either qualified (ie, IOP ≤ 18 mm Hg with medications) or complete success at 24 months of observation was 72.2%. In a univariate Cox proportional hazards model, age was the only variable that independently influenced the risk of failing 5-FU needling revision. Fourteen eyes (38.8%) had a documented complication. Needling over the plate of an AGV supplemented with 5-FU is an effective and safe choice in a significant proportion of POAG patients with elevated IOP due to encapsulation or fibrosis.
Ge, Jinying; Wang, Xijun; Tian, Meijie; Gao, Yuwei; Wen, Zhiyuan; Yu, Guimei; Zhou, Weiwei; Zu, Shulong; Bu, Zhigao
2015-05-15
Canine Distemper Virus (CDV) infects many carnivores and cause several high-mortality disease outbreaks. The current CDV live vaccine cannot be safely used in some exotic species, such as mink and ferret. Here, we generated recombinant lentogenic Newcastle disease virus (NDV) LaSota expressing either envelope glycoproyein, heamagglutinine (H) or fusion protein (F), named as rLa-CDVH and rLa-CDVF, respectively. The feasibility of these recombinant NDVs to serve as live virus-vectored CD vaccine was evaluated in minks. rLa-CDVH induced significant neutralization antibodies (NA) to CDV and provided solid protection against virulent CDV challenge. On the contrast, rLa-CDVF induced much lower NA to CDV and fail to protected mink from virulent CDV challenge. Results suggest that recombinant NDV expressing CDV H is safe and efficient candidate vaccine against CDV in mink, and maybe other host species. Copyright © 2015 Elsevier Ltd. All rights reserved.
Power and replication - designing powerful experiments
USDA-ARS?s Scientific Manuscript database
Biological research is expensive, with monetary costs to granting agencies and emotional costs to researchers. As such, biological researchers should always follow the mantra, "failure is not an option." A failed experimental design is generally manifested as an experiment with high P-values, leavin...
NASA Astrophysics Data System (ADS)
Geraskin, N. I.; Glebov, V. B.
2017-01-01
The issues of specialists training in the field of nuclear materials safe management for the countries, who have taken a way of nuclear power development are analyzed. Arguments in justification of a need of these specialists training for the new-comers are adduced. The general characteristic of the reference MS program “Nuclear materials safe management” is considered. The peculiar features of the program, which is important for graduates from the new-comers have been analyzed. The best practices got as a result of implementation of the program in recent years for the students from Kazakhstan, Belarus, Azerbaijan, Tajikistan, Iran, Turkey and other countries are presented. Finally, the directions of international cooperation in further improvement and development of the program are considered.
Trauma and the transference-countertransference: working with the bad object and the wounded self.
West, Marcus
2013-02-01
This paper focuses on the transference-countertransference dynamics that manifest in work with those individuals who experienced severe early relational trauma and, in particular, childhood sexual abuse. The literature is surveyed from Davies and Frawley's (1992a) seminal paper through to more current trauma-related and sensorimotor approaches, which deepen our understanding greatly. The rapidly shifting, powerful, conflicting and kaleidoscopic transference-countertransference dynamics are explored in the light of these views and in relation to a lengthy clinical example. The author elucidates the dual-aspect of the traumatic complex, whereby the abuser figure, which is disavowed by the patient, becomes manifest in prosecuting the analyst for the 'wounds' that the analysis evokes. The paper also explores the particular nature of the splitting processes, whereby pressure is put on the analyst to adopt an idealized role, in particular to act as a self-object, in order to enable the patient to safely express and 'be' themselves in an attempt to make up for what was not possible in childhood; the analyst will necessarily fail in this task. In the context of powerful masochisto-sadistic dynamics, the analyst's masochism is likely to be called up in the spirit of caring 'humanity' (another inevitable enactment), which can impede the progress of the analysis if not addressed. The extreme woundedness, intense affect and moral outrage associated with these dynamics are characteristic and compelling. Issues relating to disclosure, enactment and analytic attitude are also discussed. © 2013, The Society of Analytical Psychology.
Development of an Electric Motor Powered Low Cost Coconut Deshelling Machine
NASA Astrophysics Data System (ADS)
Mondal, Imdadul Hoque; Prasanna Kumar, G. V.
2016-06-01
An electric motor powered coconut deshelling machine was developed in line with the commercially available unit, but with slight modifications. The machine worked on the principle that the coconut shell can be caused to fail in shear and compressive forces. It consisted of a toothed wheel, a deshelling rod, an electric motor, and a compound chain drive. A bevelled 16 teeth sprocket with 18 mm pitch was used as the toothed wheel. Mild steel round bar of 18 mm diameter was used as the deshelling rod. The sharp edge tip of the deshelling rod was inserted below the shell to apply shear force on the shell, and the fruit was tilted toward the rotary toothed wheel to apply the compressive force on the shell. The speed of rotation of the toothed wheel was set at 34 ± 2 rpm. The output capacity of the machine was found to be 24 coconuts/h with 95 % of the total time effectively used for deshelling. The labour requirement was found to be 43 man-h/1000 nuts. About 13 % of the kernels got scraped and about 7 % got sliced during the operation. The developed coconut deshelling machine was recommended for the minimum annual use of 200 h or deshelling of 4700 coconuts per year. The cost of operation for 200 h of annual use was found to be about ` 47/h. The developed machine was found to be simple, easy to operate, energy efficient, safe and reduce drudgery involved in deshelling by conventional methods.
Failure of U.S. Public Secondary Schools in Mathematics
ERIC Educational Resources Information Center
Marder, Michael
2012-01-01
Metaphors play a powerful role in arguments about education. It is common to say schools are broken, and that the school system is failing. Here I take the metaphor seriously and briefly review an historical episode where airplanes failed seemingly for no reason at the dawn of the jet age. The responses to these failures at first with public…
The perceived compatibility of safety and production expectations in hazardous occupations.
McLain, David L; Jarrell, Kimberly A
2007-01-01
Safety hazards are unavoidable in many work environments. Employees must be both productive and safe, however, conflicting safety and production demands can negatively affect safety, production, or both. The employee's perception of the compatibility of management's safety and production expectations is a possible predictor of such consequences. This paper defines "safety-production compatibility" and describes how measures of safety-production compatibility, as well as safety pressure and production pressure, were developed. We used LISREL structural equation modeling to test the influences of safety-production compatibility, safety pressure, and production pressure on safe work behavior and interference with performing other work tasks. The 239 study participants were workers employed in diverse but hazardous occupations. Pressure to work safely was positively associated with safe work behavior. The perceived compatibility of safety and production demands positively influenced safe work behavior and reduced the interference of safety hazards performing other tasks. Safety-production compatibility was also found to mediate the relationship between trust in management and safe work behavior. The results of this field study suggest increased compatibility, and thus less conflict, between safety and production demands influences safe work behavior and the interference of safety hazards with performing other work tasks. More broadly, the worker's reaction to multiple work demands is a safety and performance influence. Safety management efforts that focus only on the hazards fail to eliminate many accidents because accidents arise from many factors including technology, safety climate, social influences, production, and safety demands. This study suggests that workers differ in their perception of the compatibility of safety and production demands. These differences will show up in safe work behavior, influencing the effectiveness of safety management efforts and the trust workers have in management's concern for safety.
Issues in the Radiation Controversy
ERIC Educational Resources Information Center
Tamplin, Arthur R.
1971-01-01
Examines the competing claims of safe" radiation levels from nuclear power plants and analyzes some of the arguments used by protagonists and antagonists. Claims that the real question, Why more power?", is becoming obscured. (AL)
Anti-backlash drive systems for multi-degree freedom devices
Lungwen Tsai; Sunlai Chang.
1993-09-14
A new and innovative concept is described for the control of backlash in gear-coupled transmission mechanisms. The concept utilizes redundant unidirectional drives to assure positive coupling of gear meshes at all times. Based on this concept, a methodology for the enumeration of admissible redundant-drive backlash-free robotic mechanisms has been established. Some typical two- and three-DOF mechanisms are disclosed. Furthermore, actuator torques have been derived as functions of either joint torques or end-effector dynamic performance requirements. A redundantly driven gear coupled transmission mechanism manipulator has a fail-safe advantage in that, except of the loss of backlash control, it can continue to function when one of its actuators fails. A two-DOF backlash-free arm has been reduced to practice to demonstrate the principle. 20 figures.
Driving with diabetes: the automatism defence.
Griffith, Richard; Tengnah, Cassam
2011-02-01
The tragic case of a district nurse killed when a car driven by a man in a hypoglycaemic state struck her while she took her regular evening walk highlights the dangers that can occur when a person with diabetes drives without regard to their condition. The man was later jailed for four and a half years for causing death by dangerous driving having been found criminally responsible for his actions because he failed to control his blood sugar levels during the journey. In this article the authors set out the likely consequences for people with diabetes who fail in their duty to ensure that they are able to drive safely and are unlikely to be affected by the adverse effects of their illness or the medication taken to control it.
NASA Technical Reports Server (NTRS)
Leucht, David K.; Koslosky, Marie J.; Kobe, David L.; Wu, Jya-Chang C.; Vavra, David A.
2011-01-01
The Space Environments Testbed (SET) is a flight controller data system for the Common Carrier Assembly. The SET-1 flight software provides the command, telemetry, and experiment control to ground operators for the SET-1 mission. Modes of operation (see dia gram) include: a) Boot Mode that is initiated at application of power to the processor card, and runs memory diagnostics. It may be entered via ground command or autonomously based upon fault detection. b) Maintenance Mode that allows for limited carrier health monitoring, including power telemetry monitoring on a non-interference basis. c) Safe Mode is a predefined, minimum power safehold configuration with power to experiments removed and carrier functionality minimized. It is used to troubleshoot problems that occur during flight. d) Operations Mode is used for normal experiment carrier operations. It may be entered only via ground command from Safe Mode.
30 CFR 75.1002 - Installation of electric equipment and conductors; permissibility.
Code of Federal Regulations, 2012 CFR
2012-07-01
... faces must be— (1) Shielded high-voltage cables supplying power to permissible longwall equipment; (2... intrinsically safe circuits; and (4) Cables and conductors supplying power to low- and medium-voltage permissible equipment. (5) Shielded high-voltage cables supplying power to permissible continuous mining...
30 CFR 75.1002 - Installation of electric equipment and conductors; permissibility.
Code of Federal Regulations, 2013 CFR
2013-07-01
... faces must be— (1) Shielded high-voltage cables supplying power to permissible longwall equipment; (2... intrinsically safe circuits; and (4) Cables and conductors supplying power to low- and medium-voltage permissible equipment. (5) Shielded high-voltage cables supplying power to permissible continuous mining...
30 CFR 75.1002 - Installation of electric equipment and conductors; permissibility.
Code of Federal Regulations, 2014 CFR
2014-07-01
... faces must be— (1) Shielded high-voltage cables supplying power to permissible longwall equipment; (2... intrinsically safe circuits; and (4) Cables and conductors supplying power to low- and medium-voltage permissible equipment. (5) Shielded high-voltage cables supplying power to permissible continuous mining...
Energy Education: Responding to the Nuclear Power Controversy.
ERIC Educational Resources Information Center
Fry-Miller, Kathleen M.
1982-01-01
Discusses problems associated with the use of nuclear power as a source of energy. Sources of exposure to radiation, the effects of exposure to radiation on children's health, and safe alternatives to nuclear power that can be taught to children are among the topics addressed. (Author/RH)
77 FR 64501 - Combined Notice of Filings #1
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-22
.... Applicants: Calvert Cliffs Nuclear Power Plant, LLC, Nine Mile Point Nuclear Station, LLC, R.E. Ginna Nuclear Power Plant, LLC. Description: Notice of Non-Material Change in Status of Nine Mile Point Nuclear..., LLC, Shooting Star Wind Project, LLC, Safe Harbor Water Power Corporation, PECO Energy Company...
49 CFR 393.23 - Power supply for lamps.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 5 2011-10-01 2011-10-01 false Power supply for lamps. 393.23 Section 393.23 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL MOTOR CARRIER SAFETY... NECESSARY FOR SAFE OPERATION Lamps, Reflective Devices, and Electrical Wiring § 393.23 Power supply for...
49 CFR 393.23 - Power supply for lamps.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 5 2010-10-01 2010-10-01 false Power supply for lamps. 393.23 Section 393.23 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL MOTOR CARRIER SAFETY... NECESSARY FOR SAFE OPERATION Lamps, Reflective Devices, and Electrical Wiring § 393.23 Power supply for...
Terrestrial Applications of Zero Boil-Off Cryogen Storage
NASA Technical Reports Server (NTRS)
Salerno, L. J.; Gaby, J.; Hastings, L.; Johnson, R.; Kittel, P.; Marquardt, E.; Plachta, D.; Arnold, James O. (Technical Monitor)
2000-01-01
Storing cryogenic propellants with zero boil off (ZBO) using a combination of active (cryocoolers) and passive technologies has recently received a great deal of attention for applications such as future long-term space missions. This paper will examine a variety of potential near-term terrestrial applications for ZBO and, where appropriate, provide a rough order of magnitude cost benefit of implementing ZBO technology. NASA's Space Shuttle power system uses supercritical propellant tanks, which are filled several days before launch. If the launch does not occur within 48-96 hours, the tanks must be drained and refilled, further delaying the launch. By implementing ZBO, boil off could be eliminated and pad hold time extended. At the launch site, vented liquid hydrogen (LH2) storage dewars lose 1200-1600 gal/day through boiloff. Implementing ZBO would eliminate this, saving $300,000-$400,000 per year. Similarly, overland trucking of LH2 from the supplier to the launch site via roadable dewars results in a cryogen loss of ten percent per tanker (1500 gal/tanker). Providing a cryocooler on board the rig would prevent this loss. Previous work investigating variable density insulation found that a 50% reduction in evaporation from a 6000 gallon dewar would save $5000 per year. For a 20 year dewar lifetime, the payback period would be less than two years. Similar benefits could be realized at other storage facilities across the nation. Within the superconductivity community, there is skepticism about using coolers, based upon reliability concerns. By providing a cooler on the dewar, lifetime could be extended while retaining fail-safe capability. If the cooler failed, it would merely lower the storage life of the dewar.
Johnson, Steve A.; English, Jr., Ronald Edward; White, Ronald K.
2001-01-01
A plurality of copper lasers, as radiant power sources, emits a beam of power carrying radiation. A plurality of fiber injection assemblies receives power from the plurality of copper lasers and injects such power into a plurality of fibers for individually transmitting the received power to a plurality of power-receiving devices. The power-transmitting fibers of the system are so arranged that power is delivered therethrough to each of the power-receiving devices such that, even if a few of the radiant power sources and/or fibers fail, the power supply to any of the power receiving devices will not completely drop to zero but will drop by the same proportionate amount.
Computational analysis on plug-in hybrid electric motorcycle chassis
NASA Astrophysics Data System (ADS)
Teoh, S. J.; Bakar, R. A.; Gan, L. M.
2013-12-01
Plug-in hybrid electric motorcycle (PHEM) is an alternative to promote sustainability lower emissions. However, the PHEM overall system packaging is constrained by limited space in a motorcycle chassis. In this paper, a chassis applying the concept of a Chopper is analysed to apply in PHEM. The chassis 3dimensional (3D) modelling is built with CAD software. The PHEM power-train components and drive-train mechanisms are intergraded into the 3D modelling to ensure the chassis provides sufficient space. Besides that, a human dummy model is built into the 3D modelling to ensure the rider?s ergonomics and comfort. The chassis 3D model then undergoes stress-strain simulation. The simulation predicts the stress distribution, displacement and factor of safety (FOS). The data are used to identify the critical point, thus suggesting the chassis design is applicable or need to redesign/ modify to meet the require strength. Critical points mean highest stress which might cause the chassis to fail. This point occurs at the joints at triple tree and bracket rear absorber for a motorcycle chassis. As a conclusion, computational analysis predicts the stress distribution and guideline to develop a safe prototype chassis.
Dangol, Manita; Yang, Huisuk; Li, Cheng Guo; Lahiji, Shayan Fakhraei; Kim, Suyong; Ma, Yonghao; Jung, Hyungil
2016-02-10
Lipophilic drugs are potential drug candidates during drug development. However, due to the need for hazardous organic solvents for their solubilization, these drugs often fail to reach the pharmaceutical market, and in doing so highlight the importance of solvent free systems. Although transdermal drug delivery systems (TDDSs) are considered prospective safe drug delivery routes, a system involving lipophilic drugs in solvent free or powder form has not yet been described. Here, we report, for the first time, a novel approach for the delivery of every kind of lipophilic drug in powder form based on an innovative polymeric system (IPS). The phase transition of powder form of lipophilic drugs due to interior chemical bonds between drugs and biodegradable polymers and formation of nano-sized colloidal structures allowed the fabrication of dissolving microneedles (DMNs) to generate a powerful TDDS. We showed that IPS based DMN with powder capsaicin enhances the therapeutic effect for treatment of the rheumatic arthritis in a DBA/1 mouse model compared to a solvent-based system, indicating the promising potential of this new solvent-free platform for lipophilic drug delivery. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Bragg-Sitton, S. M.; Webster, K. L.
2007-01-01
Nonnuclear testing can be a valuable tool in the development of an in-space nuclear power or propulsion system. In a nonnuclear test facility, electric heaters are used to simulate heat from nuclear fuel. Standard testing allows one to fully assess thermal, heat transfer, and stress related attributes of a given system but fails to demonstrate the dynamic response that would be present in an integrated, fueled reactor system. The integration of thermal hydraulic hardware tests with simulated neutronic response provides a bridge between electrically heated testing and full nuclear testing. By implementing a neutronic response model to simulate the dynamic response that would be expected in a fueled reactor system, one can better understand system integration issues, characterize integrated system response times and response and response characteristics, and assess potential design improvements with a relatively small fiscal investment. Initial system dynamic response testing was demonstrated on the integrated SAFE 100a heat pipe cooled, electrically heated reactor and heat exchanger hardware. This Technical Memorandum discusses the status of the planned dynamic test methodology for implementation in the direct-drive gas-cooled reactor testing and assesses the additional instrumentation needed to implement high-fidelity dynamic testing.
Power Goals for the NASA Exploration Program
NASA Technical Reports Server (NTRS)
Jeevarajan, J.
2009-01-01
This slide presentation reviews the requirements for electrical power for future NASA exploration missions to the lunar surface. A review of the Constellation program is included as an introduction to the review of the batteries required for safe and reliable power for the ascent stage of the Altair Lunar Lander module.
46 CFR 183.530 - Hazardous areas.
Code of Federal Regulations, 2011 CFR
2011-10-01
... equipment in spaces containing machinery powered by, or fuel tanks for, gasoline or other fuels having a... intrinsically safe system. (b) Electrical equipment in lockers used to store paint, oil, turpentine, or other flammable liquids must be explosion-proof or be part of an intrinsically safe system. (c) Explosion-proof...
The Challenge. Volume 13, Number 3, Spring 2005
ERIC Educational Resources Information Center
US Department of Education, 2005
2005-01-01
"The Challenge", a publication of the US Department of Education's office of Safe and Drug-Free Schools, provides critical information and resources to assist schools in creating safe and healthy environments for young people. This issue addresses the following topics: (1) Prevention Programs with Staying Power: What Makes Good Prevention Programs…
Energy Storage | Transportation Research | NREL
, and safe energy storage systems to power the next generation of electric-drive vehicles (EDVs). While lasting, safe, and operate at maximum efficiency in a wide range of driving conditions and climates. The Consumers, Industry, and the Environment As manufacturers develop new electric-drive vehicles, NREL acts as
Making the Spoon: Analyzing and Employing Stability Power in Counterinsurgency Operations
2007-05-11
Economic Effects of 9/11:A Retrospective Assessment. Report to Congress: Specialist in Economic Policy, 2002. Maslow , Abraham H., and Robert Frager...elements of national power in proportion to the scale of the intervention, to stabilize a failing state. As the theory of stability power requires a...sustainment and support capabilities to provide the military a counterinsurgency “spoon,” through the theory of stability power. This thesis determines if
Has Ukraine’s Path to Democracy Improved from Independence to the Orange Revolution
2006-06-01
ineffective. "Even with dozens of amendments, it failed to define either the separation of powers between the legislature and the executive branches or...Providing for a complete separation of powers between the executive and legislative branches of government, it allowed the president "…to issue decrees...complete separation of powers between president and parliament and clearly defined presidential powers. . Ultimately, Ukraine seemed to be sliding
Concept for a power system controller for large space electrical power systems
NASA Technical Reports Server (NTRS)
Lollar, L. F.; Lanier, J. R., Jr.; Graves, J. R.
1981-01-01
The development of technology for a fail-operatonal power system controller (PSC) utilizing microprocessor technology for managing the distribution and power processor subsystems of a large multi-kW space electrical power system is discussed. The specific functions which must be performed by the PSC, the best microprocessor available to do the job, and the feasibility, cost savings, and applications of a PSC were determined. A limited function breadboard version of a PSC was developed to demonstrate the concept and potential cost savings.
Flightworthy active control landing gear for a supersonic aircraft
NASA Technical Reports Server (NTRS)
Ross, I.
1980-01-01
A flightworthy active control landing gear system for a supersonic aircraft was designed to minimize aircraft loads during takeoff, impact, rollout, and taxi. The design consists of hydromechanical modifications to the existing gear and the development of a fail-safe electronic controller. analytical RESULTS INDICATE that for an aircraft sink rate of 0.914 m/sec (3 ft/sec) the system achieves a peak load reduction of 36% during landing impact.
Use of ustekinumab for severe refractory atopic dermatitis in a young teenager.
Wlodek, C; Hewitt, H; Kennedy, C T
2016-08-01
When conventional systemic immunosuppressive treatments fail in the setting of severe eczema, unlike in psoriasis, there are limited treatment options and only anecdotal evidence to help guide clinicians. There is a growing body of evidence for the use of certain biologic agents for moderate to severe eczema. We report the youngest case to date successfully and safely treated with ustekinumab for severe refractory atopic dermatitis. © 2016 British Association of Dermatologists.
Application of Micro-ramp Flow Control Devices to an Oblique Shock Interaction
NASA Technical Reports Server (NTRS)
Hirt, Stefanie; Anderson, Bernhard
2007-01-01
Tests are planned in the 15cm x 15cm supersonic wind tunnel at NASA Glenn to demonstrate the applicability of micro-ramp flow control to the management of shock wave boundary layer interactions. These tests will be used as a database for computational fluid dynamics (CFD) validation and Design of Experiments (DoE) design information. Micro-ramps show potential for mechanically simple and fail-safe boundary layer control.
Evidence-based practice guideline: wheelchair biking for the treatment of depression.
Fitzsimmons, Suzanne; Schoenfelder, Deborah Perry
2011-07-01
Depression is a problem that will continue to burden older adults and challenge health care providers. Failing to recognize and effectively treat depression in institutionalized older adults is sanctioning these members of society to live their final years in despair and emotional suffering. The wheelchair biking program described in this evidence-based practice guideline provides a refreshing, safe, innovative tool to address depression and improve quality of life in older adults.
ERIC Educational Resources Information Center
Frias, Gus
2010-01-01
In the United States of America, all students and staff have a constitutional right to attend schools that are safe, secure, and successful. Despite this right, at many public schools, education leaders have failed to ensure the safety and high academic achievement of all students. The purpose of this research study is to expand knowledge about…
Software Requirements for the A-7E Aircraft.
1992-08-31
DIWI(a) 14 ASCU SSU-20 (1,2) READ 8 DIWI(a) 15 BITE FAIL SAFE (2) READ 2 DIW3(a) 0 TACAN PARITY VALID (3) READ 2 DIW3(a) 10-14 AGE TEST EQUIPMENT (2...69 2.1.5: Arm am ent Station Control Unit ( ASCU ...times. 69 I Chapter 2 ALSPAUGH, FAULK. BRITTON, PARKER. PARNAS, AND SHORE 3 2.1.5. Armament Station Control Unit ( ASCU ) The Armament Station Control
A Physical Model for Mass Ejection in Failed Supernovae
NASA Astrophysics Data System (ADS)
Coughlin, Eric Robert; Quataert, Eliot; Fernandez, Rodrigo; Kasen, Daniel
2018-01-01
During the core collapse of a massive star, the formation of the protoneutron star is accompanied by the emission of a significant amount of mass-energy (a few tenths of a Solar mass) in the form of neutrinos. This mass-energy loss generates an outward-propagating pressure wave that steepens into a shock near the stellar surface, potentially powering a weak transient associated with an otherwise-failed supernova -- where the shock associated with the original core collapse cannot unbind the envelope in a successful explosion. We provide both rough estimates of the energy contained in the shock that powers the transient and a general formalism for analyzing the propagation and steepening of the pressure wave, and we apply this formalism to polytropic stellar models. We compare our results to simulations, and we find excellent agreement in both the early evolution of the pressure wave and in the energy contained in the shock. Our estimates provide important constraints on the observational implications of failed supernovae.
Response Variability in Commercial MOSFET SEE Qualification
George, J. S.; Clymer, D. A.; Turflinger, T. L.; ...
2016-12-01
Single-event effects (SEE) evaluation of five different part types of next generation, commercial trench MOSFETs indicates large part-to-part variation in determining a safe operating area (SOA) for drain-source voltage (V DS) following a test campaign that exposed >50 samples per part type to heavy ions. These results suggest a determination of a SOA using small sample sizes may fail to capture the full extent of the part-to-part variability. An example method is discussed for establishing a Safe Operating Area using a one-sided statistical tolerance limit based on the number of test samples. Finally, burn-in is shown to be a criticalmore » factor in reducing part-to-part variation in part response. Implications for radiation qualification requirements are also explored.« less
Less than severe worst case accidents
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sanders, G.A.
1996-08-01
Many systems can provide tremendous benefit if operating correctly, produce only an inconvenience if they fail to operate, but have extreme consequences if they are only partially disabled such that they operate erratically or prematurely. In order to assure safety, systems are often tested against the most severe environments and accidents that are considered possible to ensure either safe operation or safe failure. However, it is often the less severe environments which result in the ``worst case accident`` since these are the conditions in which part of the system may be exposed or rendered unpredictable prior to total system failure.more » Some examples of less severe mechanical, thermal, and electrical environments which may actually be worst case are described as cautions for others in industries with high consequence operations or products.« less
Response Variability in Commercial MOSFET SEE Qualification
DOE Office of Scientific and Technical Information (OSTI.GOV)
George, J. S.; Clymer, D. A.; Turflinger, T. L.
Single-event effects (SEE) evaluation of five different part types of next generation, commercial trench MOSFETs indicates large part-to-part variation in determining a safe operating area (SOA) for drain-source voltage (V DS) following a test campaign that exposed >50 samples per part type to heavy ions. These results suggest a determination of a SOA using small sample sizes may fail to capture the full extent of the part-to-part variability. An example method is discussed for establishing a Safe Operating Area using a one-sided statistical tolerance limit based on the number of test samples. Finally, burn-in is shown to be a criticalmore » factor in reducing part-to-part variation in part response. Implications for radiation qualification requirements are also explored.« less
NASA Astrophysics Data System (ADS)
Langlois, Dominic; Cousineau, Denis; Thivierge, J. P.
2014-01-01
The coordination of activity amongst populations of neurons in the brain is critical to cognition and behavior. One form of coordinated activity that has been widely studied in recent years is the so-called neuronal avalanche, whereby ongoing bursts of activity follow a power-law distribution. Avalanches that follow a power law are not unique to neuroscience, but arise in a broad range of natural systems, including earthquakes, magnetic fields, biological extinctions, fluid dynamics, and superconductors. Here, we show that common techniques that estimate this distribution fail to take into account important characteristics of the data and may lead to a sizable misestimation of the slope of power laws. We develop an alternative series of maximum likelihood estimators for discrete, continuous, bounded, and censored data. Using numerical simulations, we show that these estimators lead to accurate evaluations of power-law distributions, improving on common approaches. Next, we apply these estimators to recordings of in vitro rat neocortical activity. We show that different estimators lead to marked discrepancies in the evaluation of power-law distributions. These results call into question a broad range of findings that may misestimate the slope of power laws by failing to take into account key aspects of the observed data.
Langlois, Dominic; Cousineau, Denis; Thivierge, J P
2014-01-01
The coordination of activity amongst populations of neurons in the brain is critical to cognition and behavior. One form of coordinated activity that has been widely studied in recent years is the so-called neuronal avalanche, whereby ongoing bursts of activity follow a power-law distribution. Avalanches that follow a power law are not unique to neuroscience, but arise in a broad range of natural systems, including earthquakes, magnetic fields, biological extinctions, fluid dynamics, and superconductors. Here, we show that common techniques that estimate this distribution fail to take into account important characteristics of the data and may lead to a sizable misestimation of the slope of power laws. We develop an alternative series of maximum likelihood estimators for discrete, continuous, bounded, and censored data. Using numerical simulations, we show that these estimators lead to accurate evaluations of power-law distributions, improving on common approaches. Next, we apply these estimators to recordings of in vitro rat neocortical activity. We show that different estimators lead to marked discrepancies in the evaluation of power-law distributions. These results call into question a broad range of findings that may misestimate the slope of power laws by failing to take into account key aspects of the observed data.
Protecting Against Faults in JPL Spacecraft
NASA Technical Reports Server (NTRS)
Morgan, Paula
2007-01-01
A paper discusses techniques for protecting against faults in spacecraft designed and operated by NASA s Jet Propulsion Laboratory (JPL). The paper addresses, more specifically, fault-protection requirements and techniques common to most JPL spacecraft (in contradistinction to unique, mission specific techniques), standard practices in the implementation of these techniques, and fault-protection software architectures. Common requirements include those to protect onboard command, data-processing, and control computers; protect against loss of Earth/spacecraft radio communication; maintain safe temperatures; and recover from power overloads. The paper describes fault-protection techniques as part of a fault-management strategy that also includes functional redundancy, redundant hardware, and autonomous monitoring of (1) the operational and health statuses of spacecraft components, (2) temperatures inside and outside the spacecraft, and (3) allocation of power. The strategy also provides for preprogrammed automated responses to anomalous conditions. In addition, the software running in almost every JPL spacecraft incorporates a general-purpose "Safe Mode" response algorithm that configures the spacecraft in a lower-power state that is safe and predictable, thereby facilitating diagnosis of more complex faults by a team of human experts on Earth.
Public Health Crisis: the Need for Primary Prevention in Failed and Fragile States.
Quinn, John; Stoeva, Preslava; Zelený, Tomáš; Nanda, Toozy; Tomanová, Alžběta; Bencko, Vladimír
2017-09-01
A new 'normal' in global affairs may be erupting from large global powers to that of non-state actors and proxies committing violence through scaled conflict in a post-Westphalian world generating significant global health policy challenges. Health security of populations are multifactorial and indirectly proportional to war, conflict and disaster. Preventing conflict and avoiding the health vacuum that occurs in war and violence may be best practices for policy makers. This paper considers an approach of applying clinical primary prevention principles to global health policy. Brief policy review of current standards and practices in health security in fragile and failed states and prevention; and definitions discussion. A short case study series are presented with best practices, with risk and outcome review. The global balance of power and order may be shifting through geopolitical transference and inadequate action by major global power brokers. Health security in at risk nation-states may be decreasing as a result. Small scale conflict with large-scale violence threatens health security and may experience increased incidence and prevalence in fragile and failed states. Preventative policy to resuscitate fragile and failed states and prevent further external and internal shocks may support health and promote a positive feedback loop of further state stability and increased health security. Public health policy shift to mitigate state failure and public health crisis in war and conflict through the basis of primary prevention may provide best practices and maximize health security for at risk populations. Copyright© by the National Institute of Public Health, Prague 2017
ERIC Educational Resources Information Center
McCamey, Randy B.
2003-01-01
The need for workers in the U.S. nuclear power industry to continually update their knowledge, skills, and abilities is critical to the safe and reliable operation of the country's nuclear power facilities. To improve their skills, knowledge, and abilities, many professionals in the nuclear power industry participate in continuing professional…
Options for Affordable Fission Surface Power Systems
NASA Technical Reports Server (NTRS)
Houts, Mike; Gaddis, Steve; Porter, Ron; VanDyke, Melissa; Martin Jim; Godfroy, Tom; Bragg-Sitton, Shannon; Garber, Anne; Pearson, Boise
2006-01-01
Fission surface power systems could provide abundant power anywhere on free surface of the moon or Mars. Locations could include permanently shaded regions on the moon and high latitudes on Mars. To be fully utilized; however, fission surface power systems must be safe, have adequate performance, and be affordable. This paper discusses options for the design and development of such systems.
Prototype data terminal-multiplexer/demultiplexer
NASA Technical Reports Server (NTRS)
Leck, D. E.; Goodwin, J. E.
1972-01-01
The design and operation of a quad redundant data terminal and a multiplexer/demultiplexer (MDU) is described. The most unique feature is the design of the quad redundant data terminal. This is one of the few designs where the unit is fail/op, fail/op, fail/safe. Laboratory tests confirm that the unit will operate satisfactorily with the failure of three out of four channels. Although the design utilizes state-of-the-art technology, the waveform error checks, the voting techniques, and the parity bit checks are believed to be used in unique configurations. Correct word selection routines are also novel. The MDU design, while not redundant, utilizes, the latest state-of-the-art advantages of light coupler and interested amplifiers. Much of the technology employed was an evolution of prior NASA contracts related to the Addressable Time Division Data System. A good example of the earlier technology development was the development of a low level analog multiplexer, a high level analog multiplexer, and a digital multiplexer. A list of all drawings is included for reference and all schematic, block and timing diagrams are incorporated.
Multiple Restart Testing of a Stainless Steel Sodium Heat Pipe Module
NASA Astrophysics Data System (ADS)
Martin, James; Mireles, Omar; Reid, Robert
2005-02-01
A heat pipe cooled reactor is one of several candidate reactor concepts being considered for space power and propulsion systems to support future space exploration activities. Long life heat pipe modules, with concepts verified through a combination of theoretical analysis and experimental evaluations, would be necessary to establish the viability of this option. A number of stainless steel/sodium heat pipe modules have been designed and fabricated to support experimental testing of a Safe Affordable Fission Engine (SAFE) project, a 100-kWt core design pursued jointly by the Marshall Space Flight Center and the Los Alamos National Laboratory. One of the SAFE heat pipe modules was successfully subjected to over 200 restarts, examining the behavior of multiple passive freeze/thaw operations. Typical operation included a 1-hour startup to an average evaporator temperature of 1000 K followed by a 15-minute hold at temperature. Nominal maximum input power to the evaporator (measured at the power supply) during the hold period was 1.9 kW, with approximately 1.6 kW calculated as the axial power transfer to the condenser (the 300W difference was lost to environment at the evaporator surface). Between heating cycles the module was cooled to less than 325 K, returning the sodium to a frozen state in preparation for the next startup cycle.
High power eye-safe Er3+:YVO4 laser diode-pumped at 976 nm and emitting at 1603 nm
NASA Astrophysics Data System (ADS)
Newburgh, G. A.; Dubinskii, M.
2016-02-01
We report on the performance of an eye-safe laser based on a Er:YVO4 single crystal, diode-pumped at 976 nm (4I15/2-->4I11/2 transition) and operating at 1603 nm (4I13/2-->4I15/2 transition) with good beam quality. A 10 mm long Er3+:YVO4 slab, cut with its c-axis perpendicular to the laser cavity axis, was pumped in σ-polarization and lased in π-polarization. The laser operated in a quasi-continuous wave (Q-CW) regime with nearly 9 W output power, and with a slope efficiency of about 39% with respect to absorbed power. This is believed to be the highest efficiency and highest power achieved from an Er3+:YVO4 laser pumped in the 970-980 nm absorption band.
Core-power and decay-time limits for disabled automatic-actuation of LOFT ECCS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hanson, G.H.
1978-06-05
The Emergency Core Cooling System (ECCS) for the LOFT reactor may need to be disabled for modifications or repairs of hardware or instrumentation or for component testing during periods when the reactor system is hot and pressurized, or it may be desirable to enable the ECCS to be disabled without the necessity of cooling down and depressurizing the reactor. LTR 113-47 has shown that the LOFT ECCS can be safely bypassed or disabled when the total core power does not exceed 25 kW. A modified policy involves disabling the automatic actuation of the LOFT ECCS, but still retaining the manualmore » activation capability. Disabling of the automatic actuation can be safely utilized, without subjecting the fuel cladding to unacceptable temperatures, when the LOFT power decays to 70 kW; this power level permits a maximum delay of 20 minutes following a LOCA for the manual actuation of ECCS.« less
Disrupting Power/Entrenching Sovereignty: The Paradox of Human Rights Education
ERIC Educational Resources Information Center
Ahmed, A. Kayum
2017-01-01
While human rights education (HRE) provides the tools for emancipation, it remains susceptible to appropriation by authoritarian regimes who seek to entrench state power. Classification scholars who typologize approaches to HRE fail to acknowledge that state entities could employ human rights discourse to reinforce state sovereignty. Consequently,…
Design Research Using Game Design as an Instructional Strategy
ERIC Educational Resources Information Center
Siko, Jason; Barbour, Michael
2014-01-01
Using Homemade PowerPoint games as an instructional strategy incorporates elements of game design and constructionism in the classroom using "Microsoft PowerPoint," which is ubiquitous in schools today. However, previous research examining the use of these games has failed to show statistical differences in performance. In the second…
Enabling Persistent Peace After Negotiated Settlements
2016-12-01
event either party fails to comply with the agreements, especially on the issue of power sharing, recurrence of conflict is high . Another cause...persistent peace after a negotiated settlement when the government holds a majority of the power . Additionally, an examination of Mozambique’s civil war...provisions can be used to stabilize expectations and reduce uncertainty. When adversaries agree to share power , this action can prolong the peace by
China’s Largesse: Why China Is Generous With Foreign Aid
2017-12-01
leftist factions failed to establish a foothold for communism, and Kenyatta maintained the power of his right-wing regime. Shortly after independence...avenues of diplomatic pressure. Even if this model holds explanatory power , it is unlikely by itself to explain a state’s decisions when accepting...Global Power .............70 3. China’s Intent and the Supply and Demand of Foreign Aid
Safety and compliance of prescription spectacles ordered by the public via the Internet.
Citek, Karl; Torgersen, Daniel L; Endres, Jeffrey D; Rosenberg, Robert R
2011-09-01
This study investigated prescription spectacles ordered from online vendors and delivered directly to the public for compliance with the optical tolerance and impact resistance requirements for eyewear dispensed in the United States. Ten individuals ordered 2 pairs of spectacles from each of 10 of the most visited Internet vendors, totaling 200 eyewear orders. Spectacles ordered consisted of ranges of lens and frame materials, lens styles, and refractive corrections reflecting current distributions in the United States. Evaluations included measurement of sphere power, cylinder power and axis, add power (if indicated), horizontal prism imbalance, and impact testing. We received and evaluated 154 pairs of spectacles, comprising 308 lenses. Several spectacles were provided incorrectly, such as single vision instead of multifocal and lens treatments added or omitted. In 28.6% of spectacles, at least 1 lens failed tolerance standards for at least 1 optical parameter, and in 22.7% of spectacles, at least 1 lens failed impact testing. Overall, 44.8% of spectacles failed at least 1 parameter of optical or impact testing. Nearly half of prescription spectacles delivered directly by online vendors did not meet either the optical requirements of the patient's visual needs or the physical requirements for the patient's safety. Copyright © 2011 American Optometric Association. Published by Elsevier Inc. All rights reserved.
2003-10-15
KENNEDY SPACE CENTER, FLA. - One of many vendors displaying their products during the Spaceport Super Safety and Health Day at KSC and Cape Canaveral Air Force Station, Florida Power and Light draws a crowd during a demonstration. The annual KSC event is dedicated to reinforcing safe and healthful behaviors in the workforce.
49 CFR 232.15 - Movement of defective equipment.
Code of Federal Regulations, 2010 CFR
2010-10-01
... the safe repair of the car. (d) Computation of percent operative power brakes. (1) The percentage of operative power brakes in a train shall be based on the number of control valves in the train. The... contained on the stencil, sticker, or badge plate required by § 232.103(g) for considering the power brakes...
Improved Electromagnetic Brake
NASA Technical Reports Server (NTRS)
Martin, Toby B.
2004-01-01
A proposed design for an electromagnetic brake would increase the reliability while reducing the number of parts and the weight, relative to a prior commercially available electromagnetic brake. The reductions of weight and the number of parts could also lead to a reduction of cost. A description of the commercial brake is prerequisite to a description of the proposed electromagnetic brake. The commercial brake (see upper part of figure) includes (1) a permanent magnet and an electromagnet coil on a stator and (2) a rotor that includes a steel contact plate mounted, with tension spring loading, on an aluminum hub. The stator is mounted securely on a stationary object, which would ordinarily be the housing of a gear drive or a motor. The rotor is mounted on the shaft of the gear drive or motor. The commercial brake nominally operates in a fail-safe (in the sense of normally braking) mode: In the absence of current in the electromagnet coil, the permanent magnet pulls the contact plate, against the spring tension, into contact with the stator. To release the brake, one excites the electromagnet with a current of the magnitude and polarity chosen to cancel the magnetic flux of the permanent magnet, thereby enabling the spring tension to pull the contact plate out of contact with the stator. The fail-safe operation of the commercial brake depends on careful mounting of the rotor in relation to the stator. The rotor/stator gap must be set with a tolerance between 10 and 15 mils (between about 0.25 and about 0.38 mm). If the gap or the contact pad is thicker than the maximum allowable value, then the permanent magnetic field will not be strong enough to pull the steel plate across the gap. (For this reason, any contact pad between the contact plate and the stator must also be correspondingly thin.) If the gap exceeds the maximum allowable value because of shaft end play, it becomes impossible to set the brake by turning off the electromagnet current. Although it may still be possible to set the brake by applying an electromagnet current to aid the permanent magnetic field instead of canceling it, this action can mask an out-of-tolerance condition in the brake and it does not restore the fail-safe function of setting the brake when current is lost.
One Black, One White: Power, White Privilege, & Creating Safe Spaces
ERIC Educational Resources Information Center
Delano-Oriaran, Omobolade O.; Parks, Marguerite W.
2015-01-01
This article explores the experiences of two professors as they teach about White privilege in predominately White institutions of higher education. The authors discuss how racial potentiality shapes the classroom climates of each of the professors and then present strategies that utilize safe spaces to navigate students away from the resistance…
Better Together: SOF and Conventional Forces Integration in Security Force Assistance
2017-06-09
substantial investment in both American taxpayer dollars and military man- power ; but does it accomplish the assumptive hypothesis of conflict prevention...Arguably, the initial military incursions into Afghanistan and Iraq were textbook examples of American tactical and strategic prowess. The high ...conflict does not necessarily signify a failed or failing 48 state (i.e. Mexico or Ukraine) and likewise some states with “ high instability” did not
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sorrells, M.A.
This paper is a broad overview of industrial power distribution. Primary focus will be on selection of the various low voltage components to achieve the end product. Emphasis will be on the use of national standards to ensure a safe and well designed installation.
Obstetrical Practice and Training in Canadian Family Medicine: Conserving an Endangered Species
Klein, Michael; Reynolds, J. L.; Boucher, Francois; Malus, Michael; Rosenberg, Ellen
1984-01-01
Family practice obstetricians are an endangered species. Our practices and teaching sites must provide the correct attitudinal as well as technical messages to result in a practitioner who will be able to meet the psychosocial and medical needs of the pregnant couple. Family practice obstetrics can be as safe as care given by obstetricians provided that the family practice group functions well, that obstetrical consultants are available and supportive, and assuming that technical approaches are reserved for those truly in need. In rural areas, obstetrical ability is essential, whilst in the urban setting it helps the family physician maintain a practice involving young families. Those trainees who fail to learn basic obstetrical skills (including family centered attitudes and approaches) may in any setting come to feel, belatedly, that their training programs failed in this respect. PMID:21279123
Bardoxolone: augmenting the Yin in chronic kidney disease.
Thomas, Merlin C
2011-10-01
Nrf-2 (NF-E2-related factor 2) is a regulator of anti-oxidant, anti-inflammatory and detoxification pathways. Coordinated augmentation of these key defence pathways via Nrf-2 signalling is being investigated for the treatment of chronic diseases, including diabetes and its complications. The first to reach commercial development is the triterpenoid, bardoxolone methyl. In recent clinical trial, bardoxolone rapidly improved kidney function on average by 5-10 ml/min within 4 weeks of therapy. Importantly, this improvement was sustained during one year of active treatment. This suggests that rather that overworking a failing system, bardoxolone appeared to safely augment renal function, at least to one year. If similar improvements in kidney function can be reproduced in the upcoming BEACON trial, it will represent a major advance on conventional therapy and new way to bring balance to the failing kidney.
Space shuttle environmental control/life support systems
NASA Technical Reports Server (NTRS)
1972-01-01
This study analyzes and defines a baseline Environmental Control/Life Support System (EC/LSS) for a four-man, seven-day orbital shuttle. In addition, the impact of various mission parameters, crew size, mission length, etc. are examined for their influence on the selected system. Pacing technology items are identified to serve as a guide for application of effort to enhance the total system optimization. A fail safe-fail operation philosophy was utilized in designing the system. This has resulted in a system that requires only one daily routine operation. All other critical item malfunctions are automatically resolved by switching to redundant modes of operation. As a result of this study, it is evident that a practical, flexible, simple and long life, EC/LSS can be designed and manufactured for the shuttle orbiter within the time phase required.
Robust extraction of the aorta and pulmonary artery from 3D MDCT image data
NASA Astrophysics Data System (ADS)
Taeprasartsit, Pinyo; Higgins, William E.
2010-03-01
Accurate definition of the aorta and pulmonary artery from three-dimensional (3D) multi-detector CT (MDCT) images is important for pulmonary applications. This work presents robust methods for defining the aorta and pulmonary artery in the central chest. The methods work on both contrast enhanced and no-contrast 3D MDCT image data. The automatic methods use a common approach employing model fitting and selection and adaptive refinement. During the occasional event that more precise vascular extraction is desired or the method fails, we also have an alternate semi-automatic fail-safe method. The semi-automatic method extracts the vasculature by extending the medial axes into a user-guided direction. A ground-truth study over a series of 40 human 3D MDCT images demonstrates the efficacy, accuracy, robustness, and efficiency of the methods.
One-stage dorsal lingual mucosal graft urethroplasty for the treatment of failed hypospadias repair.
Li, Hong-Bin; Xu, Yue-Min; Fu, Qiang; Sa, Ying-Long; Zhang, Jiong; Xie, Hong
2016-01-01
The aim of this study was to retrospectively investigate the outcomes of patients who underwent one-stage onlay or inlay urethroplasty using a lingual mucosal graft (LMG) after failed hypospadias repairs. Inclusion criteria included a history of failed hypospadias repair, insufficiency of the local skin that made a reoperation with skin flaps difficult, and necessity of an oral mucosal graft urethroplasty. Patients were excluded if they had undergone a failed hypospadias repair using the foreskin or a multistage repair urethroplasty. Between January 2008 and December 2012, 110 patients with failed hypospadias repairs were treated in our center. Of these patients, 56 underwent a one-stage onlay or inlay urethroplasty using LMG. The median age was 21.8 years (range: 4-45 years). Of the 56 patients, one-stage onlay LMG urethroplasty was performed in 42 patients (group 1), and a modified Snodgrass technique using one-stage inlay LMG urethroplasty was performed in 14 (group 2). The median LMG urethroplasty length was 5.6 ± 1.6 cm (range: 4-13 cm). The mean follow-up was 34.7 months (range: 10-58 months), and complications developed in 12 of 56 patients (21.4%), including urethrocutaneous fistulas in 7 (6 in group 1, 1 in group 2) and neourethral strictures in 5 (4 in group 1, 1 in group 2). The total success rate was 78.6%. Our survey suggests that one-stage onlay or inlay urethroplasty with LMG may be an effective option to treat the patients with less available skin after failed hypospadias repairs; LMG harvesting is easy and safe, irrespective of the patient's age.
Integral Inherently Safe Light Water Reactor (I 2S-LWR)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Petrovic, Bojan; Memmott, Matthew; Boy, Guy
This final report summarizes results of the multi-year effort performed during the period 2/2013- 12/2016 under the DOE NEUP IRP Project “Integral Inherently Safe Light Water Reactors (I 2S-LWR)”. The goal of the project was to develop a concept of a 1 GWe PWR with integral configuration and inherent safety features, at the same time accounting for lessons learned from the Fukushima accident, and keeping in mind the economic viability of the new concept. Essentially (see Figure 1-1) the project aimed to implement attractive safety features, typically found only in SMRs, to a larger power (1 GWe) reactor, to addressmore » the preference of some utilities in the US power market for unit power level on the order of 1 GWe.« less
Design Optimization of Composite Structures under Uncertainty
NASA Technical Reports Server (NTRS)
Haftka, Raphael T.
2003-01-01
Design optimization under uncertainty is computationally expensive and is also challenging in terms of alternative formulation. The work under the grant focused on developing methods for design against uncertainty that are applicable to composite structural design with emphasis on response surface techniques. Applications included design of stiffened composite plates for improved damage tolerance, the use of response surfaces for fitting weights obtained by structural optimization, and simultaneous design of structure and inspection periods for fail-safe structures.
Manet, R; Schmidt, E A; Vassal, F; Charier, D; Gergelé, L
2016-01-01
External lumbar drainage (ELD) of cerebrospinal fluid (CSF) in posttraumatic refractory intracranial hypertension (ICHT) is controversial. We report our experience of ELD in ICHT associated with acute disturbance of CSF flow within subarachnoid spaces (SASs). Four adult patients admitted to the neurointensive care unit for severe TBI who presented with secondary ICHT are retrospectively reported. When refractory to second-tier therapy, if external ventricular drainage were not possible or failed, and in the absence of an indication for craniotomy to treat a mass lesion or decompressive craniectomy, we assessed the evolution of CSF volume within cranial SAS and checked the presence of basal cisterns and the absence of tonsillar herniation to evaluate interest in and the safety of ELD. As second-tier therapy failed to lower intracranial pressure (ICP; mean ICP 37 ± 5 mmHg), and computed tomography (CT) showed abnormally enlarged cranial SAS following traumatic subarachnoid hemorrhage, patients received ELD. ICP decreased, with immediate and long-term effect (mean ICP 5 mmHg ± 2 mmHg). There were no complications to report. Acute traumatic external hydrocephalus may explain some of the specific situations of secondary increased ICP, with a "normal" CT scan, that is refractory to medical treatment. In these situations, lumbar drainage should be considered to be a safe, minimally invasive, and effective surgical option.
NASA Astrophysics Data System (ADS)
Güth, Dirk; Schamoni, Markus; Maas, Jürgen
2013-09-01
No-load losses within brakes and clutches based on magnetorheological fluids are unavoidable and represent a major barrier towards their wide-spread commercial adoption. Completely torque free rotation is not yet possible due to persistent fluid contact within the shear gap. In this paper, a novel concept is presented that facilitates the controlled movement of the magnetorheological fluid from an active, torque-transmitting region into an inactive region of the shear gap. This concept enables complete decoupling of the fluid engaging surfaces such that viscous drag torque can be eliminated. In order to achieve the desired effect, motion in the magnetorheological fluid is induced by magnetic forces acting on the fluid, which requires an appropriate magnetic circuit design. In this investigation, we propose a methodology to determine suitable magnetic circuit designs with well-defined fail-safe behavior. The magnetically induced motion of magnetorheological fluids is modeled by the use of the Kelvin body force, and a multi-physics domain simulation is performed to elucidate various transitions between an engaged and disengaged operating mode. The modeling approach is validated by captured high-speed video frames which show the induced motion of the magnetorheological fluid due to the magnetic field. Finally, measurements performed with a prototype actuator prove that the induced viscous drag torque can be reduced significantly by the proposed magnetic fluid control methodology.
SUNRAYCE 1993: Working safely with lead-acid batteries and photovoltaic power systems
NASA Astrophysics Data System (ADS)
Dephillips, M. P.; Moskowitz, P. D.; Fthenakis, V. M.
1992-11-01
The US Department of Energy (DOE) is sponsoring SUNRAYCE 93 to advance tile technology and use of photovoltaics and electric vehicles. Participants will use cars powered by photovoltaic modules and lead-acid storage batteries. This brochure, prepared for students and faculty participating in this race, outlines the health hazards presented by these electrical systems and gives guidance on strategies for their safe usage. At the outset, it should be noted that working with photovoltaic systems and batteries requires electric vehicle drivers and technicians to have 'hands-on' contact with the car on a daily basis. It is important that no one work near a photovoltaic energy system or battery, either in a vehicle or on the bench, unless they familiarize themselves with the components in use and know and observe safe work practices including the safety precautions described in the manuals provided by the various equipment vendors and this document.
Efficient eye-safe neodymium doped composite yttrium gallium garnet crystal laser.
Yu, Haohai; Wang, Shuxian; Han, Shuo; Wu, Kui; Su, Liangbi; Zhang, Huaijin; Wang, Zhengping; Xu, Jun; Wang, Jiyang
2014-03-15
We report a laser-diode pumped continuous-wave (cw) and passively Q-switched eye-safe laser at about 1.42 μm with the neodymium-doped yttrium gallium garnet (Nd:YGG) crystal for the first time to our knowledge. The composite Nd:YGG crystal was developed originally. A systematic comparison of laser performance between the homogeneously doped and composite Nd:YGG crystal was made, which showed that the composite Nd:YGG manifested less thermally induced effects. Cw output power of 2.06 W was obtained with the slope efficiency of 20.7%. With a V:YAG as a saturable absorber, the passive Q-switching at 1.42 μm was gotten with the pulse width, pulse energy, and peak power of 34 ns, 46.7 μJ, and 1.4 kW, respectively. The present work should provide a potential candidate for the generation of eye-safe lasers.
NASA Astrophysics Data System (ADS)
Hadjisavvas, V.; Damianou, C.
2011-09-01
In this paper a simulation model for predicting the temperature during the application of MR-guided focused ultrasound for stroke treatment using pulsed ultrasound is presented. A single element spherically focused transducer of 5 cm diameter, focusing at 10 cm and operating at either 0.5 MHz or 1 MHz was considered. The power field was estimated using the KZK model. The temperature was estimated using the bioheat equation. The goal was to extract the acoustic parameters (power, pulse duration, duty factor and pulse repetition frequency) that maintain a temperature increase of less than 1 °C during the application of a pulse ultrasound protocol. It was found that the temperature change increases linearly with duty factor. The higher the power, the lower the duty factor needed to keep the temperature change to the safe limit of 1 °C. The higher the frequency the lower the duty factor needed to keep the temperature change to the safe limit of 1 °C. Finally, the deeper the target, the higher the duty factor needed to keep the temperature change to the safe limit of 1 °C. The simulation model was tested in brain tissue during the application of pulse ultrasound and the measured temperature was in close agreement with the simulated temperature. This simulation model is considered to be very useful tool for providing acoustic parameters (frequency, power, duty factor, pulse repetition frequency) during the application of pulsed ultrasound at various depths in tissue so that a safe temperature is maintained during the treatment. This model could be tested soon during stroke clinical trials.
Multi-agent coordination algorithms for control of distributed energy resources in smart grids
NASA Astrophysics Data System (ADS)
Cortes, Andres
Sustainable energy is a top-priority for researchers these days, since electricity and transportation are pillars of modern society. Integration of clean energy technologies such as wind, solar, and plug-in electric vehicles (PEVs), is a major engineering challenge in operation and management of power systems. This is due to the uncertain nature of renewable energy technologies and the large amount of extra load that PEVs would add to the power grid. Given the networked structure of a power system, multi-agent control and optimization strategies are natural approaches to address the various problems of interest for the safe and reliable operation of the power grid. The distributed computation in multi-agent algorithms addresses three problems at the same time: i) it allows for the handling of problems with millions of variables that a single processor cannot compute, ii) it allows certain independence and privacy to electricity customers by not requiring any usage information, and iii) it is robust to localized failures in the communication network, being able to solve problems by simply neglecting the failing section of the system. We propose various algorithms to coordinate storage, generation, and demand resources in a power grid using multi-agent computation and decentralized decision making. First, we introduce a hierarchical vehicle-one-grid (V1G) algorithm for coordination of PEVs under usage constraints, where energy only flows from the grid in to the batteries of PEVs. We then present a hierarchical vehicle-to-grid (V2G) algorithm for PEV coordination that takes into consideration line capacity constraints in the distribution grid, and where energy flows both ways, from the grid in to the batteries, and from the batteries to the grid. Next, we develop a greedy-like hierarchical algorithm for management of demand response events with on/off loads. Finally, we introduce distributed algorithms for the optimal control of distributed energy resources, i.e., generation and storage in a microgrid. The algorithms we present are provably correct and tested in simulation. Each algorithm is assumed to work on a particular network topology, and simulation studies are carried out in order to demonstrate their convergence properties to a desired solution.
A Thermal and Electrical Analysis of Power Semiconductor Devices
NASA Technical Reports Server (NTRS)
Vafai, Kambiz
1997-01-01
The state-of-art power semiconductor devices require a thorough understanding of the thermal behavior for these devices. Traditional thermal analysis have (1) failed to account for the thermo-electrical interaction which is significant for power semiconductor devices operating at high temperature, and (2) failed to account for the thermal interactions among all the levels involved in, from the entire device to the gate micro-structure. Furthermore there is a lack of quantitative studies of the thermal breakdown phenomenon which is one of the major failure mechanisms for power electronics. This research work is directed towards addressing. Using a coupled thermal and electrical simulation, in which the drift-diffusion equations for the semiconductor and the energy equation for temperature are solved simultaneously, the thermo-electrical interactions at the micron scale of various junction structures are thoroughly investigated. The optimization of gate structure designs and doping designs is then addressed. An iterative numerical procedure which incorporates the thermal analysis at the device, chip and junction levels of the power device is proposed for the first time and utilized in a BJT power semiconductor device. In this procedure, interactions of different levels are fully considered. The thermal stability issue is studied both analytically and numerically in this research work in order to understand the mechanism for thermal breakdown.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Menglu; Tu, K. N., E-mail: kntu@ucla.edu; Kim, Dong Wook
Thermal-crosstalk induced thermomigration failure in un-powered microbumps has been found in 2.5D integrated circuit (IC) circuit. In 2.5D IC, a Si interposer was used between a polymer substrate and a device chip which has transistors. The interposer has no transistors. If transistors are added to the interposer chip, it becomes 3D IC. In our test structure, there are two Si chips placed horizontally on a Si interposer. The vertical connections between the interposer and the Si chips are through microbumps. We powered one daisy chain of the microbumps under one Si chip; however, the un-powered microbumps in the neighboring chipmore » are failed with big holes in the solder layer. We find that Joule heating from the powered microbumps is transferred horizontally to the bottom of the neighboring un-powered microbumps, and creates a large temperature gradient, in the order of 1000 °C/cm, through the un-powered microbumps in the neighboring chip, so the latter failed by thermomigration. In addition, we used synchrotron radiation tomography to compare three sets of microbumps in the test structure: microbumps under electromigration, microbumps under thermomigration, and microbumps under a constant temperature thermal annealing. The results show that the microbumps under thermomigration have the largest damage. Furthermore, simulation of temperature distribution in the test structure supports the finding of thermomigration.« less
Characterization of Single-Event Burnout in Power MOSFET Using Backside Laser Testing
NASA Astrophysics Data System (ADS)
Miller, F.; Luu, A.; Prud'homme, F.; Poirot, P.; Gaillard, R.; Buard, N.; Carrire, T.
2006-12-01
This paper presents a new methodology based upon backside laser irradiations to characterize the sensitivity of power devices towards Single-Event Burnout. It is shown that this technique can be used to define the safe operating area
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hacke, Peter L
In an experiment with five module designs and multiple replicas, it is found that crystalline silicon cell modules that can pass a criterion of less than 5 percent power degradation in stress test conditions of 60 degrees Celsius, 85 percent relative humidity (RH), 96 h, and nameplate-rated system voltage bias show no power degradation by potential induced degradation in the range of 4-6 years duration in the Florida, USA environment. This data suggests that this chamber stress level is useful as a pass/fail criterion for PID, and will help ensure against degradation by system voltage stress in Florida, or lessmore » stressful climates, for at least 5 years.« less
I Don't Do School: Correlations of School Culture, Power, Fairness, and Behaviour Perceptions
ERIC Educational Resources Information Center
Robinson, Derrick; Watson, Marcia; Adams, Tempestt
2015-01-01
Student perceptions of fairness shape behavioural responses that impact the climate of a school. However, prevailing literature on student perceptions fails to critically explore culture, power, and self-concept. This study bridges these gaps through connecting student perception and self-concept as a collective and individual experience of…
Bypassing An Open-Circuit Power Cell
NASA Technical Reports Server (NTRS)
Wannemacher, Harry E.
1994-01-01
Collection of bypass circuits enables battery consisting series string of cells to continue to function when one of its cells fails in open-circuit (high-resistance) condition. Basic idea simply to shunt current around defective cell to prevent open circuit from turning off battery altogether. Bypass circuits dissipate little power and are nearly immune to false activation.
Identification and Reconfigurable Control of Impaired Multi-Rotor Drones
NASA Technical Reports Server (NTRS)
Stepanyan, Vahram; Krishnakumar, Kalmanje; Bencomo, Alfredo
2016-01-01
The paper presents an algorithm for control and safe landing of impaired multi-rotor drones when one or more motors fail simultaneously or in any sequence. It includes three main components: an identification block, a reconfigurable control block, and a decisions making block. The identification block monitors each motor load characteristics and the current drawn, based on which the failures are detected. The control block generates the required total thrust and three axis torques for the altitude, horizontal position and/or orientation control of the drone based on the time scale separation and nonlinear dynamic inversion. The horizontal displacement is controlled by modulating the roll and pitch angles. The decision making algorithm maps the total thrust and three torques into the individual motor thrusts based on the information provided by the identification block. The drone continues the mission execution as long as the number of functioning motors provide controllability of it. Otherwise, the controller is switched to the safe mode, which gives up the yaw control, commands a safe landing spot and descent rate while maintaining the horizontal attitude.
Anaesthesia and global health initiatives for children in a low-resource environment.
Hodges, Sarah C
2016-06-01
As the United Nations moves from Millennium Development Goals to Sustainable Development Goals, we find ourselves with the opportunity to influence the priority of global health initiatives. Previously, the global health community has failed to recognise the importance of access to safe, affordable surgery and developing the necessary specialities that support it as most of the funding focus had been on primary healthcare and infectious diseases. Now the WHO is publishing guidelines to safe surgery and the Lancet Commission on Global Surgery has been launched. However, this is only the start; anaesthesia remains a forgotten speciality within the world of public and global health and there are still challenges in escalating surgery in low and middle-income countries to an acceptable level that is affordable and timely. Although there is increased world interest in safe surgery and anaesthesia this has not yet been translated into a mandate that will compel countries to invest in improving levels of infrastructure, accessibility, manpower, and safety. A general anaesthetic remains a dangerous event in a child's life in resource-limited countries.
Fracture strength of flawed cylindrical pressure vessels under cryogenic temperatures
NASA Astrophysics Data System (ADS)
Christopher, T.; Sankarnarayanasamy, K.; Nageswara Rao, B.
2002-11-01
Damage tolerant and fail-safe approaches have been employed increasingly in the design of critical engineering components. In these approaches, one has to assess the residual strength of a component with an assumed pre-existing crack. In other cases, cracks may be detected during service. Then, there is a need to evaluate the residual strength of the cracked components in order to decide whether they can be continued safely or repair and replacement are imperative. A three-parameter fracture criterion is applied to correlate the fracture data on aluminium, titanium and steel materials from test results on cylindrical tanks/pressure vessels at cryogenic temperatures. Fracture parameters to generate the failure assessment diagram are determined for the materials considered in the present study. Failure pressure estimates were found to be in good agreement with test results.
Grady, Caitlin A; Kipkorir, Emmanuel C; Nguyen, Kien; Blatchley, E R
2015-06-01
In recent decades, more than 2 billion people have gained access to improved drinking water sources thanks to extensive effort from governments, and public and private sector entities. Despite this progress, many water sector development interventions do not provide access to safe water or fail to be sustained for long-term use. The authors examined drinking water quality of previously implemented water improvement projects in three communities in western Kenya and three communities in southern Vietnam. The cross-sectional study of 219 households included measurements of viable Escherichia coli. High rates of E. coli prevalence in these improved water sources were found in many of the samples. These findings suggest that measures above and beyond the traditional 'improved source' definition may be necessary to ensure truly safe water throughout these regions.
Lanier, Steven T; Lewis, Kevin C; Kendall, Mark C; Vieira, Brittany L; De Oliveira, Gildasio; Nader, Anthony; Kim, John Y S; Alghoul, Mohammed
2018-03-01
The authors' study represents the first level I evidence to assess whether intraoperative nerve blocks improve the quality of recovery from immediate tissue expander/implant breast reconstruction. A prospective, randomized, double-blinded, placebo-controlled clinical trial was conducted in which patients undergoing immediate tissue expander/implant breast reconstruction were randomized to either (1) intraoperative intercostal and pectoral nerve blocks with 0.25% bupivacaine with 1:200,000 epinephrine and 4 mg of dexamethasone or (2) sham nerve blocks with normal saline. The 40-item Quality of Recovery score, pain score, and opioid use in the postoperative period were compared statistically between groups. Power analysis ensured 80 percent power to detect a 10-point (clinically significant) difference in the 40-item Quality of Recovery score. Forty-seven patients were enrolled. Age, body mass index, laterality, mastectomy type, and lymph node dissection were similar between groups. There were no statistical differences in quality of recovery, pain burden as measured by visual analogue scale, opioid consumption, antiemetic use, or length of hospital stay between groups at 24 hours after surgery. Mean global 40-item Quality of Recovery scores were 169 (range, 155 to 182) for the treatment arm and 165 (range, 143 to 179) for the placebo arm (p = 0.36), indicating a high quality of recovery in both groups. Although intraoperative nerve blocks can be a safe adjunct to a comprehensive postsurgical recovery regimen, the authors' results indicate no effect on overall quality of recovery from tissue expander/implant breast reconstruction. Therapeutic, I.
Energy Drinks and Food Bars: Power or Hype?
... Staying Safe Videos for Educators Search English Español Energy Drinks and Food Bars: Power or Hype? KidsHealth / ... nutritivas: ¿Energía o mera exageración? The Buzz on Energy Foods Energy drinks and nutrition bars often make ...
Crewed Space Vehicle Battery Safety Requirements Revision D
NASA Technical Reports Server (NTRS)
Russell, Samuel
2017-01-01
The Crewed Space Vehicle Battery Safety Requirements document has been prepared for use by designers of battery-powered vehicles, portable equipment, and experiments intended for crewed spaceflight. The purpose of the requirements document is to provide battery designers with information on design provisions to be incorporated in and around the battery and on the verification to be undertaken to demonstrate a safe battery is provided. The term "safe battery" means that the battery is safe for ground personnel and crew members to handle and use; safe to be used in the enclosed environment of a crewed space vehicle; and safe to be mounted or used in unpressurized spaces adjacent to habitable areas. Battery design review, approval, and certification is required before the batteries can be used for ground operations and be certified for flight.
NASA Technical Reports Server (NTRS)
1991-01-01
The Model 1150 electronic spring latch, which provides controlled and timed access to a safe, was developed by Burnett Electronics Lab, Inc., San Diego, CA, and is marketed by KeyOne, Inc. also of San Diego. The Model 1150 is a spinoff from a spinoff. The original spinoff, the acoustic pinger, is an underwater transmitting device developed by Langley Research Center and the Navy for location and recovery of sounding rocket research payloads from the ocean. Long functioning life is a vital requirement for both the acoustic pinger and the Model 1150. The electronic spring latch employs the pinger power management technology to get long life out of the battery power source.
Krishnan, Shweta; Dalvie, Suchitra
2015-05-01
Although unsafe abortion continues to be a leading cause of maternal mortality in many countries in Asia, the right to safe abortion remains highly stigmatized across the region. The Asia Safe Abortion Partnership, a regional network advocating for safe abortion, produced an animated short film entitled From Unwanted Pregnancy to Safe Abortion to show in conferences, schools and meetings in order to share knowledge about the barriers to safe abortion in Asia and to facilitate conversations on the right to safe abortion. This paper describes the making of this film, its objectives, content, dissemination and how it has been used. Our experience highlights the advantages of using animated films in addressing highly politicized and sensitive issues like abortion. Animation helped to create powerful advocacy material that does not homogenize the experiences of women across a diverse region, and at the same time emphasize the need for joint activities that express solidarity. Copyright © 2015. Published by Elsevier Ltd.
NASA Technical Reports Server (NTRS)
Svejkovsky, Paul A.
1993-01-01
Protective plug resists slowly built-up pressure or automatically releases itself if pressure rises suddenly. Seals out moisture at pressures ranging from 50 micrometers of mercury to 200 pounds per square inch. Designed to seal throat of 38 Reaction Control Thrusters on Space Shuttle protecting internal components from corrosion. Plug conforms to contour of nozzle throat, where O-ring forms pressure seal. After plug inserted, cover attached by use of cover-fitting assembly. Modified versions useful in protecting engines, pumps, reaction vessels, and other industrial equipment during shipment and maintenance.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Masala, Salvatore; Roselli, Mario; Manenti, Guglielmo
A 70-year-old man with a painful vertebral metastasis was treated with combined percutaneous cryoablation and vertebroplasty therapy (CVT) in one session. The patient was suffering from diffuse visceral metastasized cholangiocarcinoma. After several weeks of back pain, magnetic resonance imaging documented a single L2 bone metastasis. In consultation with the oncologists, palliative combined CVT was administered with the aim of obtaining pain relief and bone stabilization. In our experience this combined treatment is safe and effective for immediate pain relief in painful bone metastases when other standard palliative treatments have failed.
Towards a Fail-Safe Air Force Culture: Creating a Resilient Future While Avoiding Past Mistakes
2011-02-16
for either preventing catastrophic failures or in the event they occur. The Air Force Safety process often uses the ― Swiss Cheese ‖ model to...evaluate accidents. The image of holes in the protective cheese layers (proactive and reactive measures) lining up in such a way as to allow an accident is... cheese . More importantly, however, a HRO‘s focus is on ―the process of the slices lining up as each moment where one hole aligns with another
A View From Space. NASA Systems Engineering and Test
2014-12-01
rocket ship called Atlantis came alive. Technology was ubiquitous. There were so many critical components that had to be harmonized. If it weren’t for...notwithstanding any other provision of law, no person shall be subject to a penalty for failing to comply with a collection of information if it does not display a...July 8, 2011, affirmed whether every key compo- nent could safely “go for launch.” If any component operated outside its performance enve- lope
Turkey: Background and U.S. Relations In Brief
2017-03-21
Zones,” Voice of America, March 8, 2017. 14 Ibid; Liz Sly, “Turkey’s Erdogan wants to establish a safe zone in the ISIS capital Raqqa,” Washington Post...Al Bab, a key transport hub in northern Syria that had been controlled since 2014 by the Islamic State. President Erdogan consistently refers to...the aftermath of the July 2016 failed coup), Erdogan may opt to seek closer relations with Russia, possibly at the expense of Turkey’s long-term ties
An Analysis of the Concurrent Certification Program at Fleet Readiness Center Southwest
2009-12-01
Mapping 5S Methodology Kanban Poka - yoke A3 Problem Solving Single Point Lesson Plans (SPLP) Total Productive Maintenance (TPM) 54 What...the actual demand of the customers. Kanban is as a demand signal which immediately propagates through the supply chain. D. POKA - YOKE : A Japanese...term that means "fail-safing" or "mistake- proofing." Avoiding (yokeru) inadvertent errors ( poka ) is a behavior-shaping constraint, or a method of
2006-07-01
sites. The strength member of the safety core insulators is a fiberglass belt wrapped around pins in the end fittings. Porcelain tubes cover the belt... porcelain tube and heavily tracked the fiberglass belt but left the belt intact structurally (Figure 1). Figure 1. Cutler safety core insulator ...fail-safe insulators . For these tests, the porcelain tube of the safety core insulator was replaced with a plastic see-through tube. The test report [5
When power does not corrupt: superior individuation processes among powerful perceivers.
Overbeck, J R; Park, B
2001-10-01
To examine whether powerful people fail to individuate the less powerful, the authors assigned participants to either a high-power or low-power role for a computer E-mail role play. In 3 studies, participants in the high-power role made decisions and determined the outcomes of interactions; low-power role players had no power and relied on high-power targets for outcome decisions. Studies I and 2 found that high-power perceivers better individuated low-power targets. Study 3 demonstrated that high-power role players' superior judgment can be impaired by including a task that directs their responsibility toward organizational rather than interpersonal concerns. In all, results suggest that the effect of power on social judgment may be more complex and multifaceted than has previously been acknowledged.
Reactive Power Compensation Method Considering Minimum Effective Reactive Power Reserve
NASA Astrophysics Data System (ADS)
Gong, Yiyu; Zhang, Kai; Pu, Zhang; Li, Xuenan; Zuo, Xianghong; Zhen, Jiao; Sudan, Teng
2017-05-01
According to the calculation model of minimum generator reactive power reserve of power system voltage stability under the premise of the guarantee, the reactive power management system with reactive power compensation combined generator, the formation of a multi-objective optimization problem, propose a reactive power reserve is considered the minimum generator reactive power compensation optimization method. This method through the improvement of the objective function and constraint conditions, when the system load growth, relying solely on reactive power generation system can not meet the requirement of safe operation, increase the reactive power reserve to solve the problem of minimum generator reactive power compensation in the case of load node.
Sun Safe Mode Controller Design for LADEE
NASA Technical Reports Server (NTRS)
Fusco, Jesse C.; Swei, Sean S. M.; Nakamura, Robert H.
2015-01-01
This paper presents the development of sun safe controllers which are designed to keep the spacecraft power positive and thermally balanced in the event an anomaly is detected. Employed by NASA's Lunar Atmosphere and Dust Environment Explorer (LADEE), the controllers utilize the measured sun vector and the spacecraft body rates for feedback control. To improve the accuracy of sun vector estimation, the least square minimization approach is applied to process the sensor data, which is proven to be effective and accurate. To validate the controllers, the LADEE spacecraft model engaging the sun safe mode was first simulated and then compared with the actual LADEE orbital fight data. The results demonstrated the applicability of the proposed sun safe controllers.
Precision Strike Annual Programs Review
2009-03-11
Deceleration and Stabilization Subsystem Squib Fire Unit Thermal Battery Electronic Safe and Arm Device Air Data Sensor Main ChargeControl Actuator Power ...platforms, and ground teams. • Powered , maneuverable, small, lightweight, accurate and lethal, with reduced risk of collateral damage. Raytheon Missile...requirements evolve, so will capability • Builds on powerful infrastructure • “Color of Money” timing is very different Traditional Approach Traditional IOC
Design Development Analyses in Support of a Heatpipe-Brayton Cycle Heat Exchanger
NASA Technical Reports Server (NTRS)
Steeve, Brian; VanDyke, Melissa; Majumdar, Alok; Nguyen, Dalton; Corley, Melissa; Guffee, Ray M.; Kapernick, Richard J.
2003-01-01
One of the power systems under consideration for nuclear electric propulsion or as a planetary surface power source is a heatpipe-cooled reactor coupled to a Brayton cycle. In this system, power is transferred from the heatpipes to the Brayton gas via a heat exchanger attached to the heatpipes. This paper discusses the fluid, thermal and structural analyses that were performed in support of the design of the heat exchanger to be tested in the SAFE-100 experimental program at Marshall Space Flight Center. A companion paper, "Mechanical Design and Fabrication of a SAFE-100 Heat Exchanger for use in NASA s Advanced Propulsion Thermal-hydraulic Simulator", presents the fabrication issues and prototyping studies that, together with these analyses, led to the development of this heat exchanger. An important consideration throughout the design development of the heat exchanger was its capability to be utilized for higher power and temperature applications. This paper also discusses this aspect of the design and presents designs for specific applications that are under consideration.
Major safety provisions in nuclear-powered ships
DOE Office of Scientific and Technical Information (OSTI.GOV)
Khlopkin, N.S.; Belyaev, V.M.; Dubrovin, A.M.
1984-12-01
Considerable experience has been accumulated in the Soviet Union on the design, construction and operation of nuclear-powered civilian ships: the icebreakers Lenin, Leonid Brezhnev and Sibir. The nuclear steam plants (NSP) used on these as the main energy source have been found to be highly reliable and safe, and it is desirable to use them in the future not only in icebreakers but also in transport ships for use in ice fields. The Soviet program for building and developing nuclear-powered ships has involved careful attention to safety in ships containing NSP. The experience with the design and operation of nuclearmore » icebreakers in recent years has led to the revision of safety standards for the nuclear ships and correspondingly ship NSP and international guidelines have been developed. If one meets the requirements as set forth in these documents, one has a safe basis for future Soviet nuclear-powered ships. The primary safety provisions for NSP are presented in this paper.« less
International trade and waste and fuel management issue, 2009
DOE Office of Scientific and Technical Information (OSTI.GOV)
Agnihotri, Newal
The focus of the January-February issue is on international trade and waste and fuel managment. Major articles/reports in this issue include: Innovative financing and workforce planning, by Donna Jacobs, Entergy Nuclear; Nuclear power - a long-term need, by John C. Devine, Gerald Goldsmith and Michael DeLallo, WorleyParsons; Importance of loan guarantee program, by Donald Hintz; EPC contracts for new plants, by Dave Barry, Shaw Power Group; GNEP and fuel recycling, by Alan Hanson, AREVA NC Inc.; Safe and reliable reactor, by Kiyoshi Yamauchi, Mitsubishi Heavy Industries, Ltd.; Safe, small and simple reactors, by Yoshi Sakashita, Toshiba Corporation; Nuclear power inmore » Thailand, by Tatchai Sumitra, Thailand Institute of Nuclear Technology; and, Nuclear power in Vietnam, by Tran Huu Phat, Vietnam Atomic Energy Commission. The Industry Innovation article this issue is Rectifying axial-offset-anomaly problems, by Don Adams, Tennessee Valley Authority. The Plant Profile article is Star of Stars Excellence, by Tyler Lamberts, Entergy Nuclear Operations, Inc.« less
Smith, Joel; Davidson, Eric H.
2009-01-01
Design features that ensure reproducible and invariant embryonic processes are major characteristics of current gene regulatory network models. New cis-regulatory studies on a gene regulatory network subcircuit activated early in the development of the sea urchin embryo reveal a sequence of encoded “fail-safe” regulatory devices. These ensure the maintenance of fate separation between skeletogenic and nonskeletogenic mesoderm lineages. An unexpected consequence of the network design revealed in the course of these experiments is that it enables the embryo to “recover” from regulatory interference that has catastrophic effects if this feature is disarmed. A reengineered regulatory system inserted into the embryo was used to prove how this system operates in vivo. Genomically encoded backup control circuitry thus provides the mechanism underlying a specific example of the regulative development for which the sea urchin embryo has long been famous. PMID:19822764
Popcorn-worker lung caused by corporate and regulatory negligence: an avoidable tragedy.
Egilman, David; Mailloux, Caroline; Valentin, Claire
2007-01-01
Diacetyl-containing butter flavor was identified as the cause of an outbreak of bronchiolitis obliterans (BO) and other lung diseases in popcorn-plant workers. Litigation documents show that the outbreak was both predictable and preventable. The industry trade organization was aware of BO cases in workers at butter-flavoring and popcorn-manufacturing plants but often failed to implement industrial hygiene improvements and actively hid pertinent warning information. Due to weaknesses in the organization and mandates of regulatory bodies, organizations such as NIOSH, OSHA, the FDA, particularly the "generally recognized as safe" (GRAS) system, and the EPA failed to detect and prevent the outbreak, which highlights the need for systemic changes in food-product regulation, including the need for corporations to act responsibly, for stronger regulations with active enforcement, for a restructuring of the GRAS system, and for criminal penalties against corporations and professionals who knowingly hide information relevant to worker protection.
Man-machine interface and control of the shuttle digital flight system
NASA Technical Reports Server (NTRS)
Burghduff, R. D.; Lewis, J. L., Jr.
1985-01-01
The space shuttle main engine (SSME) presented new requirements in the design of controls for large pump fed liquid rocket engine systems. These requirements were the need for built in full mission support capability, and complexity and flexibility of function not previously needed in this type of application. An engine mounted programmable digital control system was developed to meet these requirements. The engine system and controller and their function are described. Design challenges encountered during the course of development included accommodation for a very severe engine environment, the implementation of redundancy and redundancy management to provide fail operational/fail safe capability, removal of heat from the package, and significant constraints on computer memory size and processing time. The flexibility offered by programmable control reshaped the approach to engine design and development and set the pattern for future controls development in these types of applications.
Vertical interventions and system effects; have we learned anything from past experiences?
Oliveira, Charlotte; Russo, Giuliano
2015-01-01
The recent Ebola Virus Outbreak had a devastating effect on West Africa's already feeble national health systems. We suggest that such an impact turned out to be catastrophic because it hit particularly hard human resources for health and the delivery of primary healthcare services, which are cross-sectional to any health system. National and international interventions failed to understand the nature of this interaction, and concentrated on attending urgent specific vertical functions to fight the outbreak - the pillars - such as surveillance, logistics, safe burials etc. Such patchwork and vertical intervention strategy was always going to fail to tackle a system-wide problem, particularly in already fragile systems. We suggest that future interventions will have to learn from the experience of past initiatives for the introduction of HIV-AIDS services, which started as vertical programs and ended up including ever growing health system strengthening components. PMID:26523197
18 CFR 35.5 - Rejection of material submitted for filing.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Rejection of material submitted for filing. 35.5 Section 35.5 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY... that fails to comply with this Part may be rejected by the Director of the Office of Energy Market...
NASA Technical Reports Server (NTRS)
Wilson, J. P.
1994-01-01
Improved bypass device provides low-resistance current shunt around low-voltage power cell when cell fails in open-circuit condition during operation. In comparison with older bypass devices for same application, this one weighs less, generates less heat, and has lower voltage drop (less resistance). Bypass device connected in parallel with power cell. Draws very little current during normal operation of cell.
Zinc-chlorine battery plant system and method
Whittlesey, Curtis C.; Mashikian, Matthew S.
1981-01-01
A zinc-chlorine battery plant system and method of redirecting the electrical current around a failed battery module. The battery plant includes a power conditioning unit, a plurality of battery modules connected electrically in series to form battery strings, a plurality of battery strings electrically connected in parallel to the power conditioning unit, and a bypass switch for each battery module in the battery plant. The bypass switch includes a normally open main contact across the power terminals of the battery module, and a set of normally closed auxiliary contacts for controlling the supply of reactants electrochemically transformed in the cells of the battery module. Upon the determination of a failure condition, the bypass switch for the failed battery module is energized to close the main contact and open the auxiliary contacts. Within a short time, the electrical current through the battery module will substantially decrease due to the cutoff of the supply of reactants, and the electrical current flow through the battery string will be redirected through the main contact of the bypass switch.
Homeland Security: There’s an App for That
2017-03-01
bombings at the country’s train station and airport, mobile and terrestrial radio networks began to fail.5 The Belgian officers were using the mobile...suicide bombings at the country’s train station and airport, mobile and terrestrial radio networks began to fail. One officer deployed to the event...63 Alberts and Hayes, Power to the Edge, 199. 64 Thom Dick, “Will a Smartphone Replace Your Mobile Radio?” EMS World, July 1, 2016, http
The Challenge of a Community Park: Engaging Young Children in Powerful Lessons In Democracy
ERIC Educational Resources Information Center
Cole, Bronwyn; McGuire, Margit
2011-01-01
For young children to engage and learn in school, they need to feel safe in the classroom and on the playground right from the first day. They also need learning experiences that are active and meaningful--that engage them cognitively, affectively, and operatively. Feeling safe requires knowledge about places, rules, codes of behavior, and the…
Failure at the top: How power undermines collaborative performance.
Hildreth, John Angus D; Anderson, Cameron
2016-02-01
All too commonly, we see groups of leaders fail to accomplish their stated goals when working together--legislators who cannot agree on a bill, heads of state who cannot draft meaningful environmental policy, or boards of trustees who make disastrous decisions for their school. The current research examines whether groups of leaders fail as often as they do in part because of the power each leader is accustomed to possessing among his or her constituents. In multiple studies we found that high power individuals, when working together in groups, performed worse than did other groups: individuals randomly assigned power in an initial task were less creative when they then worked together in groups on a subsequent task (Studies 1A and 4). Individuals with higher power who worked together in groups were also less likely to reach agreement on a difficult negotiation task, whether these groups comprised actual executives from an extant organization (Study 2) or participants randomly assigned power in the laboratory (Study 3). Mediation analyses suggest that groups of high power individuals performed worse because they fought over their relative status in the group, were less focused on the task, and shared information with each other less effectively. However, high power individuals were more effective when working on tasks that required less coordination: they were more creative (Studies 1B and 4) and persisted longer on a difficult task than other groups. Therefore, group processes are the key problem for groups of high power individuals when they work together. (c) 2016 APA, all rights reserved).
Evans, Ellen W; Redmond, Elizabeth C
2015-04-01
Increased listeriosis incidence among older adults (≥ 60 years) has been reported internationally, with many cases reported to be sporadic and associated with ready-to-eat (RTE) food products with extended refrigerated shelf life. Given that the home kitchen is recognized as a significant location where foodborne illnesses are acquired, it is important that consumers implement safe food practices to minimize risks. This is crucial for vulnerable consumers, such as older adults. Consumer food safety recommendations in the United Kingdom to reduce the risk of listeriosis at home include (i) following "use-by" dates on unopened prepacked RTE food products, (ii) consuming RTE food products within 2 days of opening, and (iii) ensuring the safe operating temperatures of domestic refrigerators (≤ 5 °C). This study utilized observation, self-reporting, and microbiological analysis to determine actual food storage practices to identify behavioral risk factors. A domestic kitchen survey was conducted in older adult (≥ 60 years) consumers' domestic kitchens (n = 100) in South Wales, United Kingdom. Forty-one percent of foods in home refrigerators were beyond the use-by date, of which 11% were unopened RTE food products commonly associated with listeriosis. Sixty-six percent of opened RTE foods had been or were intended to be stored beyond the recommended 2 days after opening. Older adults failed to ensure safe refrigeration temperatures, with 50% of central storage and 85% of door storage areas operating at temperatures >5 °C. Older refrigerators operated at significantly (P < 0.05) higher temperatures. Given that Listeria monocytogenes was isolated in 2% of kitchens, these findings suggest that storage malpractices may have a greater effect on the potential risk of listeriosis than its presence alone. The study has determined that many older adults fail to adhere to recommendations and subject RTE foods associated with L. monocytogenes to prolonged storage at unsafe temperatures which may render food unsafe for consumption.
Fractional laser skin resurfacing.
Alexiades-Armenakas, Macrene R; Dover, Jeffrey S; Arndt, Kenneth A
2012-11-01
Laser skin resurfacing (LSR) has evolved over the past 2 decades from traditional ablative to fractional nonablative and fractional ablative resurfacing. Traditional ablative LSR was highly effective in reducing rhytides, photoaging, and acne scarring but was associated with significant side effects and complications. In contrast, nonablative LSR was very safe but failed to deliver consistent clinical improvement. Fractional LSR has achieved the middle ground; it combined the efficacy of traditional LSR with the safety of nonablative modalities. The first fractional laser was a nonablative erbium-doped yttrium aluminum garnet (Er:YAG) laser that produced microscopic columns of thermal injury in the epidermis and upper dermis. Heralding an entirely new concept of laser energy delivery, it delivered the laser beam in microarrays. It resulted in microscopic columns of treated tissue and intervening areas of untreated skin, which yielded rapid reepithelialization. Fractional delivery was quickly applied to ablative wavelengths such as carbon dioxide, Er:YAG, and yttrium scandium gallium garnet (2,790 nm), providing more significant clinical outcomes. Adjustable laser parameters, including power, pitch, dwell time, and spot density, allowed for precise determination of percent surface area, affected penetration depth, and clinical recovery time and efficacy. Fractional LSR has been a significant advance to the laser field, striking the balance between safety and efficacy.
Management of Sleep Disordered Breathing in Patients with Heart Failure.
Oates, Connor P; Ananthram, Manjula; Gottlieb, Stephen S
2018-06-01
This paper reviews treatment options for sleep disordered breathing (SDB) in patients with heart failure. We sought to identify therapies for SDB with the best evidence for long-term use in patients with heart failure and to minimize uncertainties in clinical practice by examining frequently discussed questions: what is the role of continuous positive airway pressure (CPAP) in patients with heart failure? Is adaptive servo-ventilation (ASV) safe in patients with heart failure? To what extent is SDB a modifiable risk factor? Consistent evidence has demonstrated that the development of SDB in patients with heart failure is a poor prognostic indicator and a risk factor for cardiovascular mortality. However, despite numerous available interventions for obstructive sleep apnea and central sleep apnea, it remains unclear what effect these therapies have on patients with heart failure. To date, all major randomized clinical trials have failed to demonstrate a survival benefit with SDB therapy and one major study investigating the use of adaptive servo-ventilation demonstrated harm. Significant questions persist regarding the management of SDB in patients with heart failure. Until appropriately powered trials identify a treatment modality that increases cardiovascular survival in patients with SDB and heart failure, a patient's heart failure management should remain the priority of medical care.
Conceptual studies for a mercury target circuit
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sigg, B.
1996-06-01
For the now favored target design of the European Spallation Source project, i.e. the version using mercury as target material, a basic concept of the primary system has been worked out. It does not include a detailed design of the various components of the target circuit, but tries to outline a feasible solution for the system. Besides the removal of the thermal power of about 3MW produced in the target by the proton beam, the primary system has to satisfy a number of other requirements related to processing, safety, and operation. The basic proposal uses an electromagnetic pump and amore » mercury-water intermediate heat excanger, but other alternatives are also being discussed. Basic safety requirements, i.e. protection against radiation and toxic mercury vapours, are satisfied by a design using an air-tight primary system containment, double-walled tubes in the intermediate heat exchanger, a fail-safe system for decay heat removal, and a remote handling facility for the active part of the system. Much engineering work has still to be done, because many details of the design of the mercury and gas processing systems remain to be clarified, the thermal-hydraulic components need further optimisation, the system for control and instrumentation is only known in outline and a through safety analysis will be required.« less
Arthroscopy of the Nondistractable Hip: A Novel Extracapsular Approach
Doron, Ran; Amar, Eyal; Rath, Ehud; Sampson, Thomas; Ochiai, Derek; Matsuda, Dean K.
2014-01-01
Adequate traction to achieve hip joint distraction is essential for avoiding iatrogenic injury to the joint during hip arthroscopy. An inability to distract the joint is a relative contraindication for hip arthroscopy. This report describes a novel technique involving an extracapsular approach to gain safe access to a hip joint that fails a trial of traction during positioning for hip arthroscopy. The anterolateral portal is established under fluoroscopic guidance. The arthroscope is positioned on the lateral rim of the acetabulum. A shaver, introduced through a modified anterior portal, is used to facilitate capsular exposure. An arthroscopic capsular incision is made proximal to the lateral acetabular rim and extended anteriorly with a radiofrequency probe. Osteoplasty of the anterolateral acetabular rim is carried out with a burr while protecting the labrum. Distraction of the hip is then possible, allowing safe central-compartment access and subsequent chondrolabral procedures. PMID:25685682
Restaurant Cooking Trends and Increased Risk for Campylobacter Infection.
Jones, Anna K; Rigby, Dan; Burton, Michael; Millman, Caroline; Williams, Nicola J; Jones, Trevor R; Wigley, Paul; O'Brien, Sarah J; Cross, Paul
2016-07-01
In the United Kingdom, outbreaks of Campylobacter infection are increasingly attributed to undercooked chicken livers, yet many recipes, including those of top chefs, advocate short cooking times and serving livers pink. During 2015, we studied preferences of chefs and the public in the United Kingdom and investigated the link between liver rareness and survival of Campylobacter. We used photographs to assess chefs' ability to identify chicken livers meeting safe cooking guidelines. To investigate the microbiological safety of livers chefs preferred to serve, we modeled Campylobacter survival in infected chicken livers cooked to various temperatures. Most chefs correctly identified safely cooked livers but overestimated the public's preference for rareness and thus preferred to serve them more rare. We estimated that 19%-52% of livers served commercially in the United Kingdom fail to reach 70°C and that predicted Campylobacter survival rates are 48%-98%. These findings indicate that cooking trends are linked to increasing Campylobacter infections.
Anticipating Terrorist Safe Havens from Instability Induced Conflict
NASA Astrophysics Data System (ADS)
Shearer, Robert; Marvin, Brett
This chapter presents recent methods developed at the Center for Army Analysis to classify patterns of nation-state instability that lead to conflict. The ungoverned areas endemic to failed nation-states provide terrorist organizations with safe havens from which to plan and execute terrorist attacks. Identification of those states at risk for instability induced conflict should help to facilitate effective counter terrorism policy planning efforts. Nation-states that experience instability induced conflict are similar in that they share common instability factors that make them susceptible to experiencing conflict. We utilize standard pattern classification algorithms to identify these patterns. First, we identify features (political, military, economic and social) that capture the instability of a nation-state. Second, we forecast the future levels of these features for each nation-state. Third, we classify each future state’s conflict potential based upon the conflict level of those states in the past most similar to the future state.
Target-fueled nuclear reactor for medical isotope production
DOE Office of Scientific and Technical Information (OSTI.GOV)
Coats, Richard L.; Parma, Edward J.
A small, low-enriched, passively safe, low-power nuclear reactor comprises a core of target and fuel pins that can be processed to produce the medical isotope .sup.99Mo and other fission product isotopes. The fuel for the reactor and the targets for the .sup.99Mo production are the same. The fuel can be low enriched uranium oxide, enriched to less than 20% .sup.235U. The reactor power level can be 1 to 2 MW. The reactor is passively safe and maintains negative reactivity coefficients. The total radionuclide inventory in the reactor core is minimized since the fuel/target pins are removed and processed after 7more » to 21 days.« less
Golden, Max C; Wanless, Brandon J; David, Jairus R D; Kottapalli, Bala; Lineback, D Scott; Talley, Ryan J; Glass, Kathleen A
2017-08-01
Clostridium botulinum may be of concern in prepared refrigerated meals, for which strict cold chain management cannot be guaranteed. This study evaluated the effect of temperature, product composition, and cultured celery juice powder (CCJP) as a source of nitrite on the inhibition of botulinum toxin formation in two experimental (meat- and vegetable-based) prepared meals. Data obtained from the challenge study were compared with a published mathematical model to determine whether the model is fail-safe with regard to the tested meals. Treatments were inoculated with proteolytic C. botulinum, vacuum packaged, cooked at 90°C for 10 min, and assayed for botulinum toxin at appropriate intervals in samples stored at 10, 15, or 20°C for up to 8 weeks. None of the treatments stored at 10°C for 8 weeks supported toxin production by proteolytic C. botulinum. The addition of CCJP delayed toxin production by 1 and 3 weeks in cauliflower potatoes and in Dijon pork, respectively, stored at 15°C. Toxin production was delayed by 1 week at 20°C when CCJP was added to the cauliflower potatoes. This study found that the predictive model was fail-safe but was overly conservative for the experimental meals described. Finally, this study confirms that product composition, the addition of nitrite via CCJP, storage time, and temperature play important roles in the inhibition of toxin formation by proteolytic C. botulinum.
Research on the Application of Risk-based Inspection for the Boiler System in Power Plant
NASA Astrophysics Data System (ADS)
Li, Henan
2017-12-01
Power plant boiler is one of the three main equipment of coal-fired power plants, is very tall to the requirement of the safe and stable operation, in a significant role in the whole system of thermal power generation, a risk-based inspection is a kind of pursuit of security and economy of unified system management idea and method, can effectively evaluate equipment risk and reduce the operational cost.
Energy Storage for the Power Grid
Imhoff, Carl; Vaishnav, Dave; Wang, Wei
2018-05-30
The iron vanadium redox flow battery was developed by researchers at Pacific Northwest National Laboratory as a solution to large-scale energy storage for the power grid. This technology provides the energy industry and the nation with a reliable, stable, safe, and low-cost storage alternative for a cleaner, efficient energy future.
29 CFR 1926.303 - Abrasive wheels and tools.
Code of Federal Regulations, 2013 CFR
2013-07-01
... and tools. (a) Power. All grinding machines shall be supplied with sufficient power to maintain the spindle speed at safe levels under all conditions of normal operation. (b) Guarding. (1) Grinding machines..., nut, and outer flange may be exposed on machines designed as portable saws. (c) Use of abrasive wheels...
29 CFR 1926.303 - Abrasive wheels and tools.
Code of Federal Regulations, 2014 CFR
2014-07-01
... and tools. (a) Power. All grinding machines shall be supplied with sufficient power to maintain the spindle speed at safe levels under all conditions of normal operation. (b) Guarding. (1) Grinding machines..., nut, and outer flange may be exposed on machines designed as portable saws. (c) Use of abrasive wheels...
29 CFR 1926.303 - Abrasive wheels and tools.
Code of Federal Regulations, 2012 CFR
2012-07-01
... and tools. (a) Power. All grinding machines shall be supplied with sufficient power to maintain the spindle speed at safe levels under all conditions of normal operation. (b) Guarding. (1) Grinding machines..., nut, and outer flange may be exposed on machines designed as portable saws. (c) Use of abrasive wheels...
Government: Nuclear Safety in Doubt a Year after Accident.
ERIC Educational Resources Information Center
Ember, Lois R.
1980-01-01
A year after the accident at Three Mile Island (TMI), the signals transmitted to the public are still confused. Industry says that nuclear power is safe and that the aftermath of TMI ushers in a new era of safety. Antinuclear activists say TMI sounded nuclear power's death knell. (Author/RE)
Another Look at the Power of Meta-Analysis in the Solomon Four-Group Design.
ERIC Educational Resources Information Center
Sawilowsky, Shlomo S.; Markman, Barry S.
This paper demonstrates that a meta-analysis technique applied to the Solomon Four-Group Design (SFGD) can fail to find significance even though an earlier "weaker" test may have found significance. The meta-analysis technique was promoted by Braver and Braver as the most powerful single test for analyzing data from an SFGD. They…
Not Waving but Drowning: A Review of Tufte's "The Cognitive Style of PowerPoint"
ERIC Educational Resources Information Center
Kangas, Brian D.
2012-01-01
"The Cognitive Style of PowerPoint: Pitching Out Corrupts Within" by Edward Tufte (2006) condemns the software for failing to help users achieve many of the goals of an effective presentation and instead offers a low resolution platform with a deeply hierarchical single-path structure capable of convening a trivial amount of information even over…
Partial power, partial knowledge: accounting for the dis-integration of a Costa Rican cooperative
Susannah R. McCandless; Marla R. Emery
2008-01-01
Drawing on the writings of Foucault, we argue that the multiple-service cooperative at the core of a Costa Rican highland municipality failed due to an incomplete transformation from sovereign to governmental regimes at the regional scale. The cooperative challenged sovereign power, held by the local patron and private biological reserves, with a governance model based...
47 CFR 74.708 - Class A TV and digital Class A TV station protection.
Code of Federal Regulations, 2012 CFR
2012-10-01
... SERVICES Low Power TV, TV Translator, and TV Booster Stations § 74.708 Class A TV and digital Class A TV... booster station or change the facilities of an existing station will not be accepted if it fails to... prior to the date the low power TV, TV translator, or TV booster application is filed. (c) Applications...
47 CFR 74.708 - Class A TV and digital Class A TV station protection.
Code of Federal Regulations, 2011 CFR
2011-10-01
... SERVICES Low Power TV, TV Translator, and TV Booster Stations § 74.708 Class A TV and digital Class A TV... booster station or change the facilities of an existing station will not be accepted if it fails to... prior to the date the low power TV, TV translator, or TV booster application is filed. (c) Applications...
47 CFR 74.708 - Class A TV and digital Class A TV station protection.
Code of Federal Regulations, 2013 CFR
2013-10-01
... SERVICES Low Power TV, TV Translator, and TV Booster Stations § 74.708 Class A TV and digital Class A TV... booster station or change the facilities of an existing station will not be accepted if it fails to... prior to the date the low power TV, TV translator, or TV booster application is filed. (c) Applications...
47 CFR 74.708 - Class A TV and digital Class A TV station protection.
Code of Federal Regulations, 2014 CFR
2014-10-01
... SERVICES Low Power TV, TV Translator, and TV Booster Stations § 74.708 Class A TV and digital Class A TV... booster station or change the facilities of an existing station will not be accepted if it fails to... prior to the date the low power TV, TV translator, or TV booster application is filed. (c) Applications...
Powerful Failure: How the National Education Association Fails to Use Its Influence for Education
ERIC Educational Resources Information Center
Association of American Educators Foundation, 2010
2010-01-01
The National Education Association (NEA) is America's oldest education association, and it has become one of America's most powerful unions. It boasts 3.2 million members nationwide and is comprised of more than half of the public school teachers in the United States. Its annual reported receipts in 2009 totaled more than $377 million. The NEA's…
Stevens, Nicholas; Salmon, Paul
2015-01-01
Footpaths provide an integral component of our urban environments and have the potential to act as safe places for people and the focus for community life. Despite this, the approach to designing footpaths that are safe while providing this sense of place often occurs in silos. There is often very little consideration given to how designing for sense of place impacts safety and vice versa. The aim of this study was to use a systems analysis and design framework to develop a design template for an 'ideal' footpath system that embodies both safety and sense of place. This was achieved through using the first phase of the Cognitive Work Analysis framework, Work Domain Analysis, to specify a model of footpaths as safe places for pedestrians. This model was subsequently used to assess two existing footpath environments to determine the extent to which they meet the design requirements specified. The findings show instances where the existing footpaths both meet and fail to meet the design requirements specified. Through utilising a systems approach for footpaths, this paper has provided a novel design template that can inform new footpath design efforts or be used to evaluate the extent to which existing footpaths achieve their safety and sense of place requirements. Copyright © 2014 Elsevier Ltd. All rights reserved.
Stevens, Nicholas; Salmon, Paul
2014-11-01
Footpaths provide an integral component of our urban environments and have the potential to act as safe places for people and the focus for community life. Despite this, the approach to designing footpaths that are safe while providing this sense of place often occurs in silos. There is often very little consideration given to how designing for sense of place impacts safety and vice versa. The aim of this study was to use a systems analysis and design framework to develop a design template for an 'ideal' footpath system that embodies both safety and sense of place. This was achieved through using the first phase of the Cognitive Work Analysis framework, Work Domain Analysis, to specify a model of footpaths as safe places for pedestrians. This model was subsequently used to assess two existing footpath environments to determine the extent to which they meet the design requirements specified. The findings show instances where the existing footpaths both meet and fail to meet the design requirements specified. Through utilising a systems approach for footpaths, this paper has provided a novel design template that can inform new footpath design efforts or be used to evaluate the extent to which existing footpaths achieve their safety and sense of place requirements. Copyright © 2014 Elsevier Ltd. All rights reserved.
Two-Dimensional Wavelike Spinel Lithium Titanate for Fast Lithium Storage
Liu, Jiehua; Wei, Xiangfeng; Liu, Xue-Wei
2015-01-01
Safe fast-charging lithium-ion batteries (LIBs) have huge potential market size on demand according to their shortened charging time for high-power devices. Zero-strain spinel Li4Ti5O12 is one of ideal candidates for safe high-power batteries owing to its good cycling performance, low cost and safety. However, the inherent insulating characteristic of LTO seriously limits its high-rate capability. In this work, we successfully synthesize novel wavelike spinel LTO nanosheets using a facile ‘co-hydrolysis’ method, which is superior to molten-salt approach and traditional solvothermal method in some respects. The unique 2D structures have single-crystal framework with shortened path for Li ion transport. As a result, the N-doped 2D wavelike LTO with 0.6 wt.% of ‘carbon joint’ not only exhibits exciting capacity of ~180 and ~150 mA h g−1 for fast lithium storage at high discharge/charge rates of 1.7 and 8.5 A g−1 (10C and 50C) respectively, but also shows excellent low-temperature performance at −20°C. In addition, the cost may be further decreased due to recycled functional reagents. This novel nanostructured 2D LTO anode material makes it possible to develop safe fast-charging high-power lithium ion batteries. PMID:25985465
Grumman evaluates Space Station thermal control and power systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kandebo, S.W.
1985-09-01
Attention is given to the definition of requirements for the NASA Space Station's electrical power and thermal control systems, which must be highly dependable to minimize the need for external support and will embody a highly flexible modular design concept. Module maintenance will be performed by in-orbit replacement of failed modules, and energy storage system growth will be accomplished by the incorporation of additional modules. Both photovoltaic and solar heat-driven electrical generator concepts are under consideration as the basis of the power system.
Rossetti, Gianluca; del Genio, Gianmattia; Maffettone, Vincenzo; Fei, Landino; Brusciano, Luigi; Limongelli, Paolo; Pizza, Francesco; Tolone, Salvatore; Di Martino, Maria; del Genio, Federica; del Genio, Alberto
2009-01-01
Laparoscopic Heller myotomy with antireflux procedure seems the procedure of choice in the treatment of patients with esophageal achalasia. Persistent or recurrent symptoms occur in 10% to 20% of patients. Few reports on reoperation after failed Heller myotomy have been published. No author has reported the realization of a total fundoplication in these patient groups. The aim of this study is to evaluate the efficacy of laparoscopic reoperation with the realization of a total fundoplication after failed Heller myotomy for esophageal achalasia. From 1992 to December 2007, 5 out of a series of 242 patients (2.1%), along with 2 patients operated elsewhere, underwent laparoscopic reintervention for failed Heller myotomy. Symptoms leading to reoperation included persistent dysphagia in 3 patients, recurrent dysphagia in another 3, and heartburn in 1 patient. Mean time from the first to the second operation was 49.7 months (range, 4-180 months). Always, the intervention was completed via a laparoscopic approach and a Nissen-Rossetti fundoplication was realized or left in place after a complete Heller myotomy. Mean operative time was 160 minutes (range, 60-245 minutes). Mean postoperative hospital stay was 3.1 +/- 1.5 days. No major morbidity or mortality occurred. At a mean follow-up of 16.1 months, reoperation must be considered successful in 5 out of 7 patients (71.4%). The dysphagia DeMeester score fell from 2.71 +/- 0.22 to 0.91 +/- 0.38 postoperatively. The regurgitation score changed from 2.45 +/- 0.34 to 0.68 +/- 0.23. Laparoscopic reoperation for failed Heller myotomy with the realization of a total fundoplication is safe and is associated with good long-term results if performed by an experienced surgeon in a center with a long tradition of esophageal surgery.
Onimaru, Manabu; Inoue, Haruhiro; Ikeda, Haruo; Yoshida, Akira; Santi, Esperanza Grace; Sato, Hiroki; Ito, Hiroaki; Maselli, Roberta; Kudo, Shin-ei
2013-10-01
Surgical Heller myotomy has high rates of successful long-term results, but failed cases still remain. Moreover, the treatment strategy in patients with surgical myotomy failure is controversial. Recently, peroral endscopic myotomy (POEM) was reported to be efficient and safe in primary treatment of achalasia. In this study, we aimed to evaluate the efficacy and safety of POEM for surgical myotomy failure as a rescue second-line treatment, and we discuss the treatment options adapted in achalasia recurrence. A total of 315 consecutive achalasia patients received POEM from September 2008 to December 2012 in our hospital. Eleven (3.5%) patients who had persistent or recurrent achalasia and had received surgical myotomy as a first-line treatment from other hospitals were included in this study. Patient background, barium swallow studies, esophagogastroduodenoscopy (EGD), manometry, and symptom scores were prospectively evaluated. In principle, all patients in whom surgical myotomy failed received pneumatic balloon dilatation (PBD) as the first line "rescue" treatment, and only if PBD failed were patients considered for rescue POEM. The PBD alone was effective in 1 patient, and in the remaining 10 patients, rescue POEM was performed successfully without complications. Three months after rescue POEM, significant reduction in lower esophageal sphincter (LES) resting pressures (22.1 ± 6.6 mmHg vs 10.9 ± 4.5 mmHg, p < 0.01) and Eckardt symptom scores (6.5 ± 1.3 vs 1.1 ± 1.3, p < 0.001) were observed. Short-term results of POEM for failed surgical myotomy were excellent. Long-term results are awaited. Copyright © 2013 American College of Surgeons. Published by Elsevier Inc. All rights reserved.
Children's recognition of dangerous household products: child development and poisoning risk.
Schwebel, David C; Wells, Hayley; Johnston, Anna
2015-03-01
Preliterate children may be poisoned because they fail to distinguish safe versus hazardous household products. Study 1: A total of 228 children aged 18-54 months completed four tasks assessing ability to recognize product safety. Study 2: A total of 68 children aged 17-31 months chose products to drink from pairs of dangerous versus beverage bottles. Study 3: A total of 119 children aged 18-42 months sorted 12 objects into toys, things you can drink, and things that are bad/dangerous. Left alone, children frequently touched dangerous household products. Children frequently misidentified poisonous products as safe. Some developmental trends emerged. The following packaging features apparently helped children recognize danger: black bottle color; opaque packaging; salient symbols like insects; lack of pointy spouts; squared, not round, bottles; and metal, not plastic, containers. Developing cognition helps preliterate children distinguish safe from dangerous household products. Multiple aspects of product packaging may reduce child poisoning risk if implemented by industry or policy. © The Author 2014. Published by Oxford University Press on behalf of the Society of Pediatric Psychology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Development of Self-Remediating Packaging for Safe and Secure Transport of Infectious Substances.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Guilinger, Terry Rae; Gaudioso, Jennifer M; Aceto, Donato Gonzalo
As George W. Bush recognized in November 2001, "Infectious diseases make no distinctions among people and recognize no borders." By their very nature, infectious diseases of natural or intentional (bioterrorist) origins are capable of threatening regional health systems and economies. The best mechanism for minimizing the spread and impact of infectious disease is rapid disease detection and diagnosis. For rapid diagnosis to occur, infectious substances (IS) must be transported very quickly to appropriate laboratories, sometimes located across the world. Shipment of IS is problematic since many carriers, concerned about leaking packages, refuse to ship this material. The current packaging doesmore » not have any ability to neutralize or kill leaking IS. The technology described here was developed by Sandia National Laboratories to provide a fail-safe packaging system for shipment of IS that will increase the likelihood that critical material can be shipped to appropriate laboratories following a bioterrorism event or the outbreak of an infectious disease. This safe and secure packaging method contains a novel decontaminating material that will kill or neutralize any leaking infectious organisms; this feature will decrease the risk associated with shipping IS, making transport more efficient. 3 DRAFT4« less
Digital Device Architecture and the Safe Use of Flash Devices in Munitions
NASA Technical Reports Server (NTRS)
Katz, Richard B.; Flowers, David; Bergevin, Keith
2017-01-01
Flash technology is being utilized in fuzed munition applications and, based on the development of digital logic devices in the commercial world, usage of flash technology will increase. Digital devices of interest to designers include flash-based microcontrollers and field programmable gate arrays (FPGAs). Almost a decade ago, a study was undertaken to determine if flash-based microcontrollers could be safely used in fuzes and, if so, how should such devices be applied. The results were documented in the Technical Manual for the Use of Logic Devices in Safety Features. This paper will first review the Technical Manual and discuss the rationale behind the suggested architectures for microcontrollers and a brief review of the concern about data retention in flash cells. An architectural feature in the microcontroller under study will be discussed and its use will show how to screen for weak or failed cells during manufacture, storage, or immediately prior to use. As was done for microcontrollers a decade ago, architectures for a flash-based FPGA will be discussed, showing how it can be safely used in fuzes. Additionally, architectures for using non-volatile (including flash-based) storage will be discussed for SRAM-based FPGAs.
Analysis of failed nuclear plant components
NASA Astrophysics Data System (ADS)
Diercks, D. R.
1993-12-01
Argonne National Laboratory has conducted analyses of failed components from nuclear power- gener-ating stations since 1974. The considerations involved in working with and analyzing radioactive compo-nents are reviewed here, and the decontamination of these components is discussed. Analyses of four failed components from nuclear plants are then described to illustrate the kinds of failures seen in serv-ice. The failures discussed are (1) intergranular stress- corrosion cracking of core spray injection piping in a boiling water reactor, (2) failure of canopy seal welds in adapter tube assemblies in the control rod drive head of a pressurized water reactor, (3) thermal fatigue of a recirculation pump shaft in a boiling water reactor, and (4) failure of pump seal wear rings by nickel leaching in a boiling water reactor.
NASA Astrophysics Data System (ADS)
Tatalović, Mićo
2013-02-01
A power struggle at one of Serbia's largest and best known science institutes has led to its director being forced to resign after allegedly failing to restructure the lab, as Mićo Tatalović reports.
Study of the emission performance of high-power klystrons: SLAC XK-5
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhao, Y.
1981-07-01
There are hundreds of high power klystrons operated in the Linac gallery and about fifty to sixty tubes fail every year. The lifetime ranges from a few thousand up to seventy thousand hours except those which fail during an early period. The overall percentage of failures due to emission problems is approximately 25%. It is also noted that a 10% increase in mean lifetime of klystrons will reduce the overall cost per hour as much as a 10% increase in efficiency. Therefore, it is useful to find some method to predict the expected life of an individual tube. The finalmore » goal has not been attained yet, but some useful information was obtained. It is thought that this information might be helpful for those people who will study this subject further.« less
NASA Astrophysics Data System (ADS)
Perez, Pedro B.; Hamawi, John N.
2017-09-01
Nuclear power plant radiation protection design features are based on radionuclide source terms derived from conservative assumptions that envelope expected operating experience. Two parameters that significantly affect the radionuclide concentrations in the source term are failed fuel fraction and effective fission product appearance rate coefficients. Failed fuel fraction may be a regulatory based assumption such as in the U.S. Appearance rate coefficients are not specified in regulatory requirements, but have been referenced to experimental data that is over 50 years old. No doubt the source terms are conservative as demonstrated by operating experience that has included failed fuel, but it may be too conservative leading to over-designed shielding for normal operations as an example. Design basis source term methodologies for normal operations had not advanced until EPRI published in 2015 an updated ANSI/ANS 18.1 source term basis document. Our paper revisits the fission product appearance rate coefficients as applied in the derivation source terms following the original U.S. NRC NUREG-0017 methodology. New coefficients have been calculated based on recent EPRI results which demonstrate the conservatism in nuclear power plant shielding design.
Unique and massive Chernobyl cranes for deconstruction activities in the new safe confinement
DOE Office of Scientific and Technical Information (OSTI.GOV)
Parameswaran, N. A. Vijay; Chornyy, Igor; Owen, Rob
2013-07-01
On 26 April 1986, the worst nuclear power plant accident in history occurred at the Chernobyl plant in Ukraine (then part of the Soviet Union). The destruction of Unit 4 sent highly radioactive fallout over Belarus, Russia, Ukraine, and Europe. The object shelter-a containment sarcophagus-was built in November 1986 to limit exposure to radiation. However, it has only a planned 25-year lifespan and would probably not survive even a moderate seismic event in a region that has more than its share of such events. It was time to take action. One of the largest tasks that are in progress ismore » the design and construction of the New Safe Confinement (NSC). The NSC is an engineered enclosure for the entire object shelter that includes a suite of process equipment. The process equipment will be used for the dismantling of the destroyed Chernobyl Nuclear Power Plant Unit. One of the major mechanical handling systems to be installed in the new safe confinement is the Main Cranes System. The planned decontamination and decommissioning or dismantling activities will require the handling of heavily shielded waste disposal casks containing nuclear fuel as well as lifting and transporting extremely large structural elements. These activities, to be performed within the new safe confinement, will require large and sophisticated cranes. The article will focus on the current progress of the new safe confinement and of the main cranes system for the decommissioning or dismantling activities. (authors)« less
Radiotoxicity and decay heat power of spent nuclear fuel of VVER type reactors at long-term storage.
Bergelson, B R; Gerasimov, A S; Tikhomirov, G V
2005-01-01
Radiotoxicity and decay heat power of the spent nuclear fuel of VVER-1000 type reactors are calculated during storage time up to 300,000 y. Decay heat power of radioactive waste (radwaste) determines parameters of the heat removal system for the safe storage of spent nuclear fuel. Radiotoxicity determines the radiological hazard of radwaste after its leakage and penetration into the environment.
Emerging needs for mobile nuclear powerplants
NASA Technical Reports Server (NTRS)
Anderson, J. L.
1972-01-01
Incentives for broadening the present role of civilian nuclear power to include mobile nuclear power plants that are compact, lightweight, and safe are examined. Specifically discussed is the growing importance of: (1) a new international cargo transportation capability, and (2) the capability for development of resources in previously remote regions of the earth including the oceans and the Arctic. This report surveys present and potential systems (vehicles, remote stations, and machines) that would both provide these capabilities and require enough power to justify using mobile nuclear reactor power plants.
Limiting factors to advancing thermal battery technology for naval applications
NASA Astrophysics Data System (ADS)
Davis, Patrick B.; Winchester, Clinton S.
1991-10-01
Thermal batteries are primary reserve electrochemical power sources using molten salt electrolyte which experience little effective aging while in storage or dormant deployment. Thermal batteries are primarily used in military applications, and are currently used in a wide variety of Navy devices such as missiles, torpedoes, decays, and training targets, usually as power supplies in guidance, propulsion, and Safe/Arm applications. Technology developments have increased the available energy and power density ratings by an order of magnitude in the last ten years. Present thermal batteries, using lithium anodes and metal sulfide cathodes, are capable of performing applications where only less rugged and more expensive silver oxide/zinc or silver/magnesium chloride seawater batteries could serve previously. Additionally, these batteries are capable of supplanting lithium/thionyl chloride reserve batteries in a variety of specifically optimized designs. Increases in thermal battery energy and power density capabilities are not projected to continue with the current available technology. Several battery designs are now at the edge of feasibility and safety. Since future naval systems are likely to require continued growth of battery energy and power densities, there must be significant advances in battery technology. Specifically, anode alloy composition and new cathode materials must be investigated to allow for safe development and deployment of these high power, higher energy density batteries.
Drinkwater, Eric J; Galna, Brook; McKenna, Michael J; Hunt, Patrick H; Pyne, David B
2007-05-01
During the concentric movement of the bench press, there is an initial high-power push after chest contact, immediately followed by a characteristic area of low power, the so-called "sticking region." During high-intensity lifting, a decline in power can result in a failed lift attempt. The purpose of this study was to determine the validity of an optical encoder to measure power and then employ this device to determine power changes during the initial acceleration and sticking region during fatiguing repeated bench press training. Twelve subjects performed a free weight bench press, a Smith Machine back squat, and a Smith Machine 40-kg bench press throw for power validation measures. All barbell movements were simultaneously monitored using cinematography and an optical encoder. Eccentric and concentric mean and peak power were calculated using time and position data derived from each method. Validity of power measures between the video (criterion) and optical encoder scores were evaluated by standard error of the estimate (SEE) and coefficient of variation (CV). Seven subjects then performed 4 sets of 6 free weight bench press repetitions progressively increasing from 85 to 95% of their 6 repetition maximum, with each repetition continually monitored by an optical encoder. The SEE for power ranged from 3.6 to 14.4 W (CV, 1.0-3.0%; correlation, 0.97-1.00). During the free weight bench press training, peak power declined by approximately 55% (p < 0.01) during the initial acceleration phase of the final 2 repetitions of the final set. Although decreases in power of the sticking point were significant (p < 0.01), as early as repetition 5 (-40%) they reached critically low levels in the final 2 repetitions (>-95%). In conclusion, the optical encoder provided valid measures of kinetics during free weight resistance training movements. The decline in power during the initial acceleration phase appears a factor in a failed lift attempt at the sticking point.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-14
..., and made a simple comparison. Based on the IEC report, the human body can withstand up to four times....\\3\\ The flow of this amount of AC through the human body may result in perception of the current and... considered to be safe) corresponds to 8 mA of DC (that is also considered to be safe for the human body).\\4...
Casimir meets Poisson: improved quark/gluon discrimination with counting observables
Frye, Christopher; Larkoski, Andrew J.; Thaler, Jesse; ...
2017-09-19
Charged track multiplicity is among the most powerful observables for discriminating quark- from gluon-initiated jets. Despite its utility, it is not infrared and collinear (IRC) safe, so perturbative calculations are limited to studying the energy evolution of multiplicity moments. While IRC-safe observables, like jet mass, are perturbatively calculable, their distributions often exhibit Casimir scaling, such that their quark/gluon discrimination power is limited by the ratio of quark to gluon color factors. In this paper, we introduce new IRC-safe counting observables whose discrimination performance exceeds that of jet mass and approaches that of track multiplicity. The key observation is that trackmore » multiplicity is approximately Poisson distributed, with more suppressed tails than the Sudakov peak structure from jet mass. By using an iterated version of the soft drop jet grooming algorithm, we can define a “soft drop multiplicity” which is Poisson distributed at leading-logarithmic accuracy. In addition, we calculate the next-to-leading-logarithmic corrections to this Poisson structure. If we allow the soft drop groomer to proceed to the end of the jet branching history, we can define a collinear-unsafe (but still infrared-safe) counting observable. Exploiting the universality of the collinear limit, we define generalized fragmentation functions to study the perturbative energy evolution of collinear-unsafe multiplicity.« less
Casimir meets Poisson: improved quark/gluon discrimination with counting observables
DOE Office of Scientific and Technical Information (OSTI.GOV)
Frye, Christopher; Larkoski, Andrew J.; Thaler, Jesse
Charged track multiplicity is among the most powerful observables for discriminating quark- from gluon-initiated jets. Despite its utility, it is not infrared and collinear (IRC) safe, so perturbative calculations are limited to studying the energy evolution of multiplicity moments. While IRC-safe observables, like jet mass, are perturbatively calculable, their distributions often exhibit Casimir scaling, such that their quark/gluon discrimination power is limited by the ratio of quark to gluon color factors. In this paper, we introduce new IRC-safe counting observables whose discrimination performance exceeds that of jet mass and approaches that of track multiplicity. The key observation is that trackmore » multiplicity is approximately Poisson distributed, with more suppressed tails than the Sudakov peak structure from jet mass. By using an iterated version of the soft drop jet grooming algorithm, we can define a “soft drop multiplicity” which is Poisson distributed at leading-logarithmic accuracy. In addition, we calculate the next-to-leading-logarithmic corrections to this Poisson structure. If we allow the soft drop groomer to proceed to the end of the jet branching history, we can define a collinear-unsafe (but still infrared-safe) counting observable. Exploiting the universality of the collinear limit, we define generalized fragmentation functions to study the perturbative energy evolution of collinear-unsafe multiplicity.« less
VARIABLE AREA CONTROL ROD FOR NUCLEAR REACTOR
Huston, N.E.
1960-05-01
A control rod is described which permits continual variation of its absorbing strength uniformly along the length of the rod. The rod is fail safe and is fully inserted into the core but changes in its absorbing strength do not produce axial flux distortion. The control device comprises a sheet containing a material having a high thermal-neutron absorption cross section. A pair of shafts engage the sheet along the longitudinal axis of the shafts and gears associated with the shafts permit winding and unwinding of the sheet around the shafts.
NASA Technical Reports Server (NTRS)
Morrison, Jonathan
2010-01-01
Environmental issues are a key driver. The need for better mechanisms to enable discipline hopping/crossover (materials (MEMS), control, fluids). Better sensors and actuators and better communication for these to be developed. Better understanding of the needs of the turbomachinery industry, especially in identifying where flow control can be beneficial (e.g., variable intake geometry). Challenge for flow control to be fail-safe, or to be developed for non-critical control gains (e.g., noise). more detailed information on stage through-flow behaviour (with/without control) increased use of laser interrogation (PIV, PTV, MTV).
Management of Plantar Hyperhidrosis with Endoscopic Lumbar Sympathectomy.
Rieger, Roman
2016-11-01
Primary plantar hyperhidrosis is defined as excessive secretion of the sweat glands of the feet and may lead to significant limitations in private and professional lifestyle and reduction of health-related quality of life. Conservative therapy measures usually fail to provide sufficient relieve of symptoms and do not allow long-lasting elimination of hyperhidrosis. Endoscopic lumbar sympathectomy appears to be a safe and effective procedure for eliminating excessive sweating of the feet and improves quality of life of patients with severe plantar hyperhidrosis. Copyright © 2016 Elsevier Inc. All rights reserved.
How to block and tackle the face.
Zide, B M; Swift, R
1998-03-01
Regional blocking techniques as noted in dentistry, anesthesia, and anatomy texts may result in inconsistent and imperfect analgesia when needed for facial aesthetic surgery. The advent of laser facial surgery and more complicated aesthetic facial procedures has thus increased the demand for anesthesia support. Surgeons should know a fail-safe method of nerve blocks. Fresh cadaver dissections are used to demonstrate a series of eight regional nerve-blocking routes. This sequence of bilateral blocks will routinely provide profound full facial anesthesia. Certain groupings of blocks are effective for perioral or periorbital laser surgery.
Effects of an Er, Cr:YSGG laser on canine oral hard tissues
NASA Astrophysics Data System (ADS)
Rizoiu, Ioana-Mihaela; Kimmel, Andrew I.; Eversole, Lewis R.
1996-12-01
Beagle dogs were utilized to assess the biologic effects of an Er, Cr:YSGG hard tissue cutting laser and results were compared with conventional mechanical preparations of enamel and dentin. Intraoperative pulpal temperature fluctuations were recorded with thermocouples. The laser cuts failed to induce inflammation in the pulps except in teeth with intentional pulp exposures for both methods. No increase in temperature was detected with the laser. It is concluded that this laser system may be safely employed for tooth preparations without causing adverse pulpal effects.