Sample records for failure analysis conducted

  1. Failure Investigation of Radiant Platen Superheater Tube of Thermal Power Plant Boiler

    NASA Astrophysics Data System (ADS)

    Ghosh, D.; Ray, S.; Mandal, A.; Roy, H.

    2015-04-01

    This paper highlights a case study of typical premature failure of a radiant platen superheater tube of 210 MW thermal power plant boiler. Visual examination, dimensional measurement and chemical analysis, are conducted as part of the investigations. Apart from these, metallographic analysis and fractography are also conducted to ascertain the probable cause of failure. Finally it has been concluded that the premature failure of the super heater tube can be attributed to localized creep at high temperature. The corrective actions has also been suggested to avoid this type of failure in near future.

  2. High-Temperature Graphitization Failure of Primary Superheater Tube

    NASA Astrophysics Data System (ADS)

    Ghosh, D.; Ray, S.; Roy, H.; Mandal, N.; Shukla, A. K.

    2015-12-01

    Failure of boiler tubes is the main cause of unit outages of the plant, which further affects the reliability, availability and safety of the unit. So failure analysis of boiler tubes is absolutely essential to predict the root cause of the failure and the steps are taken for future remedial action to prevent the failure in near future. This paper investigates the probable cause/causes of failure of the primary superheater tube in a thermal power plant boiler. Visual inspection, dimensional measurement, chemical analysis, metallographic examination and hardness measurement are conducted as the part of the investigative studies. Apart from these tests, mechanical testing and fractographic analysis are also conducted as supplements. Finally, it is concluded that the superheater tube is failed due to graphitization for prolonged exposure of the tube at higher temperature.

  3. A Proposal of Operational Risk Management Method Using FMEA for Drug Manufacturing Computerized System

    NASA Astrophysics Data System (ADS)

    Takahashi, Masakazu; Nanba, Reiji; Fukue, Yoshinori

    This paper proposes operational Risk Management (RM) method using Failure Mode and Effects Analysis (FMEA) for drug manufacturing computerlized system (DMCS). The quality of drug must not be influenced by failures and operational mistakes of DMCS. To avoid such situation, DMCS has to be conducted enough risk assessment and taken precautions. We propose operational RM method using FMEA for DMCS. To propose the method, we gathered and compared the FMEA results of DMCS, and develop a list that contains failure modes, failures and countermeasures. To apply this list, we can conduct RM in design phase, find failures, and conduct countermeasures efficiently. Additionally, we can find some failures that have not been found yet.

  4. Probabilistic structural analysis of aerospace components using NESSUS

    NASA Technical Reports Server (NTRS)

    Shiao, Michael C.; Nagpal, Vinod K.; Chamis, Christos C.

    1988-01-01

    Probabilistic structural analysis of a Space Shuttle main engine turbopump blade is conducted using the computer code NESSUS (numerical evaluation of stochastic structures under stress). The goal of the analysis is to derive probabilistic characteristics of blade response given probabilistic descriptions of uncertainties in blade geometry, material properties, and temperature and pressure distributions. Probability densities are derived for critical blade responses. Risk assessment and failure life analysis is conducted assuming different failure models.

  5. Microstructure Evolution and Failure Analysis of an Aluminum-Copper Cathode Conductive Head Produced by Explosive Welding

    NASA Astrophysics Data System (ADS)

    Wei, Yanni; Luo, Yongguang; Qu, Hongtao; Zou, Juntao; Liang, Shuhua

    2017-12-01

    In this paper, microstructure evolution and failure analysis of the aluminum-copper interface of cathode conductive heads during their use were studied. The interface morphologies, compositions, conductivity and mechanical properties were investigated and analyzed. Obvious corrosion was found on the surface of the contact interface, which was more prevalent on an Al matrix. The crack increased sharply in the local metallurgical bonding areas on the interface, with the compound volume having no significant change. The phase transformation occurred on the interface during use, which was investigated using the elemental composition and x-ray diffraction pattern. The microhardness near the interface increased accordingly. An obvious electrical conductivity decrease appeared on the Al/Cu interface of the cathode conductive head after use over a specific time interval. Therefore, the deterioration of the microstructures and corrosion are the primary factors that affect the electrical conductivity and effective bonding, which will lead to eventual failure.

  6. 33 CFR 154.804 - Review, certification, and initial inspection.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ..., property, and the environment if an accident were to occur; and (4) If a quantitative failure analysis is... quantitative failure analysis. (e) The certifying entity must conduct all initial inspections and witness all...

  7. 33 CFR 154.804 - Review, certification, and initial inspection.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., property, and the environment if an accident were to occur; and (4) If a quantitative failure analysis is... quantitative failure analysis. (e) The certifying entity must conduct all initial inspections and witness all...

  8. 33 CFR 154.804 - Review, certification, and initial inspection.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., property, and the environment if an accident were to occur; and (4) If a quantitative failure analysis is... quantitative failure analysis. (e) The certifying entity must conduct all initial inspections and witness all...

  9. 33 CFR 154.804 - Review, certification, and initial inspection.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., property, and the environment if an accident were to occur; and (4) If a quantitative failure analysis is... quantitative failure analysis. (e) The certifying entity must conduct all initial inspections and witness all...

  10. Failure environment analysis tool applications

    NASA Astrophysics Data System (ADS)

    Pack, Ginger L.; Wadsworth, David B.

    1993-02-01

    Understanding risks and avoiding failure are daily concerns for the women and men of NASA. Although NASA's mission propels us to push the limits of technology, and though the risks are considerable, the NASA community has instilled within, the determination to preserve the integrity of the systems upon which our mission and, our employees lives and well-being depend. One of the ways this is being done is by expanding and improving the tools used to perform risk assessment. The Failure Environment Analysis Tool (FEAT) was developed to help engineers and analysts more thoroughly and reliably conduct risk assessment and failure analysis. FEAT accomplishes this by providing answers to questions regarding what might have caused a particular failure; or, conversely, what effect the occurrence of a failure might have on an entire system. Additionally, FEAT can determine what common causes could have resulted in other combinations of failures. FEAT will even help determine the vulnerability of a system to failures, in light of reduced capability. FEAT also is useful in training personnel who must develop an understanding of particular systems. FEAT facilitates training on system behavior, by providing an automated environment in which to conduct 'what-if' evaluation. These types of analyses make FEAT a valuable tool for engineers and operations personnel in the design, analysis, and operation of NASA space systems.

  11. Failure environment analysis tool applications

    NASA Technical Reports Server (NTRS)

    Pack, Ginger L.; Wadsworth, David B.

    1993-01-01

    Understanding risks and avoiding failure are daily concerns for the women and men of NASA. Although NASA's mission propels us to push the limits of technology, and though the risks are considerable, the NASA community has instilled within, the determination to preserve the integrity of the systems upon which our mission and, our employees lives and well-being depend. One of the ways this is being done is by expanding and improving the tools used to perform risk assessment. The Failure Environment Analysis Tool (FEAT) was developed to help engineers and analysts more thoroughly and reliably conduct risk assessment and failure analysis. FEAT accomplishes this by providing answers to questions regarding what might have caused a particular failure; or, conversely, what effect the occurrence of a failure might have on an entire system. Additionally, FEAT can determine what common causes could have resulted in other combinations of failures. FEAT will even help determine the vulnerability of a system to failures, in light of reduced capability. FEAT also is useful in training personnel who must develop an understanding of particular systems. FEAT facilitates training on system behavior, by providing an automated environment in which to conduct 'what-if' evaluation. These types of analyses make FEAT a valuable tool for engineers and operations personnel in the design, analysis, and operation of NASA space systems.

  12. Failure environment analysis tool applications

    NASA Technical Reports Server (NTRS)

    Pack, Ginger L.; Wadsworth, David B.

    1994-01-01

    Understanding risks and avoiding failure are daily concerns for the women and men of NASA. Although NASA's mission propels us to push the limits of technology, and though the risks are considerable, the NASA community has instilled within it, the determination to preserve the integrity of the systems upon which our mission and, our employees lives and well-being depend. One of the ways this is being done is by expanding and improving the tools used to perform risk assessment. The Failure Environment Analysis Tool (FEAT) was developed to help engineers and analysts more thoroughly and reliably conduct risk assessment and failure analysis. FEAT accomplishes this by providing answers to questions regarding what might have caused a particular failure; or, conversely, what effect the occurrence of a failure might have on an entire system. Additionally, FEAT can determine what common causes could have resulted in other combinations of failures. FEAT will even help determine the vulnerability of a system to failures, in light of reduced capability. FEAT also is useful in training personnel who must develop an understanding of particular systems. FEAT facilitates training on system behavior, by providing an automated environment in which to conduct 'what-if' evaluation. These types of analyses make FEAT a valuable tool for engineers and operations personnel in the design, analysis, and operation of NASA space systems.

  13. Ply-level failure analysis of a graphite/epoxy laminate under bearing-bypass loading

    NASA Technical Reports Server (NTRS)

    Naik, R. A.; Crews, J. H., Jr.

    1988-01-01

    A combined experimental and analytical study was conducted to investigate and predict the failure modes of a graphite/epoxy laminate subjected to combined bearing and bypass loading. Tests were conducted in a test machine that allowed the bearing-bypass load ratio to be controlled while a single-fastener coupon was loaded to failure in either tension or compression. Onset and ultimate failure modes and strengths were determined for each test case. The damage-onset modes were studied in detail by sectioning and micrographing the damaged specimens. A two-dimensional, finite-element analysis was conducted to determine lamina strains around the bolt hole. Damage onset consisted of matrix cracks, delamination, and fiber failures. Stiffness loss appeared to be caused by fiber failures rather than by matrix cracking and delamination. An unusual offset-compression mode was observed for compressive bearing-bypass laoding in which the specimen failed across its width along a line offset from the hole. The computed lamina strains in the fiber direction were used in a combined analytical and experimental approach to predict bearing-bypass diagrams for damage onset from a few simple tests.

  14. Ply-level failure analysis of a graphite/epoxy laminate under bearing-bypass loading

    NASA Technical Reports Server (NTRS)

    Naik, R. A.; Crews, J. H., Jr.

    1990-01-01

    A combined experimental and analytical study was conducted to investigate and predict the failure modes of a graphite/epoxy laminate subjected to combined bearing and bypass loading. Tests were conducted in a test machine that allowed the bearing-bypass load ratio to be controlled while a single-fastener coupon was loaded to failure in either tension or compression. Onset and ultimate failure modes and strengths were determined for each test case. The damage-onset modes were studied in detail by sectioning and micrographing the damaged specimens. A two-dimensional, finite-element analysis was conducted to determine lamina strains around the bolt hole. Damage onset consisted of matrix cracks, delamination, and fiber failures. Stiffness loss appeared to be caused by fiber failures rather than by matrix cracking and delamination. An unusual offset-compression mode was observed for compressive bearing-bypass loading in which the specimen failed across its width along a line offset from the hole. The computed lamina strains in the fiber direction were used in a combined analytical and experimental approach to predict bearing-bypass diagrams for damage onset from a few simple tests.

  15. 33 CFR 154.2020 - Certification and recertification-owner/operator responsibilities.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Procedures,” and in Military Standard MIL-STD-882B for a quantitative failure analysis. For assistance in... quantitative failure analysis is also conducted, the level of safety attained is at least one order of...

  16. Investigation into Cause of High Temperature Failure of Boiler Superheater Tube

    NASA Astrophysics Data System (ADS)

    Ghosh, D.; Ray, S.; Roy, H.; Shukla, A. K.

    2015-04-01

    The failure of the boiler tubes occur due to various reasons like creep, fatigue, corrosion and erosion. This paper highlights a case study of typical premature failure of a final superheater tube of 210 MW thermal power plant boiler. Visual examination, dimensional measurement, chemical analysis, oxide scale thickness measurement, microstructural examination are conducted as part of the investigations. Apart from these investigations, sulfur print, Energy Dispersive spectroscopy (EDS) and X ray diffraction analysis (XRD) are also conducted to ascertain the probable cause of failure of final super heater tube. Finally it has been concluded that the premature failure of the super heater tube can be attributed to the combination of localized high tube metal temperature and loss of metal from the outer surface due to high temperature corrosion. The corrective actions have also been suggested to avoid this type of failure in near future.

  17. Finite Element Creep-Fatigue Analysis of a Welded Furnace Roll for Identifying Failure Root Cause

    NASA Astrophysics Data System (ADS)

    Yang, Y. P.; Mohr, W. C.

    2015-11-01

    Creep-fatigue induced failures are often observed in engineering components operating under high temperature and cyclic loading. Understanding the creep-fatigue damage process and identifying failure root cause are very important for preventing such failures and improving the lifetime of engineering components. Finite element analyses including a heat transfer analysis and a creep-fatigue analysis were conducted to model the cyclic thermal and mechanical process of a furnace roll in a continuous hot-dip coating line. Typically, the roll has a short life, <1 year, which has been a problem for a long time. The failure occurred in the weld joining an end bell to a roll shell and resulted in the complete 360° separation of the end bell from the roll shell. The heat transfer analysis was conducted to predict the temperature history of the roll by modeling heat convection from hot air inside the furnace. The creep-fatigue analysis was performed by inputting the predicted temperature history and applying mechanical loads. The analysis results showed that the failure was resulted from a creep-fatigue mechanism rather than a creep mechanism. The difference of material properties between the filler metal and the base metal is the root cause for the roll failure, which induces higher creep strain and stress in the interface between the weld and the HAZ.

  18. NASA Structural Analysis Report on the American Airlines Flight 587 Accident - Local Analysis of the Right Rear Lug

    NASA Technical Reports Server (NTRS)

    Raju, Ivatury S; Glaessgen, Edward H.; Mason, Brian H; Krishnamurthy, Thiagarajan; Davila, Carlos G

    2005-01-01

    A detailed finite element analysis of the right rear lug of the American Airlines Flight 587 - Airbus A300-600R was performed as part of the National Transportation Safety Board s failure investigation of the accident that occurred on November 12, 2001. The loads experienced by the right rear lug are evaluated using global models of the vertical tail, local models near the right rear lug, and a global-local analysis procedure. The right rear lug was analyzed using two modeling approaches. In the first approach, solid-shell type modeling is used, and in the second approach, layered-shell type modeling is used. The solid-shell and the layered-shell modeling approaches were used in progressive failure analyses (PFA) to determine the load, mode, and location of failure in the right rear lug under loading representative of an Airbus certification test conducted in 1985 (the 1985-certification test). Both analyses were in excellent agreement with each other on the predicted failure loads, failure mode, and location of failure. The solid-shell type modeling was then used to analyze both a subcomponent test conducted by Airbus in 2003 (the 2003-subcomponent test) and the accident condition. Excellent agreement was observed between the analyses and the observed failures in both cases. From the analyses conducted and presented in this paper, the following conclusions were drawn. The moment, Mx (moment about the fuselage longitudinal axis), has significant effect on the failure load of the lugs. Higher absolute values of Mx give lower failure loads. The predicted load, mode, and location of the failure of the 1985-certification test, 2003-subcomponent test, and the accident condition are in very good agreement. This agreement suggests that the 1985-certification and 2003- subcomponent tests represent the accident condition accurately. The failure mode of the right rear lug for the 1985-certification test, 2003-subcomponent test, and the accident load case is identified as a cleavage-type failure. For the accident case, the predicted failure load for the right rear lug from the PFA is greater than 1.98 times the limit load of the lugs. I.

  19. Failure analysis of stainless steel femur fixation plate.

    PubMed

    Hussain, P B; Mohammad, M

    2004-05-01

    Failure analysis was performed to investigate the failure of the femur fixation plate which was previously fixed on the femur of a girl. Radiography, metallography, fractography and mechanical testing were conducted in this study. The results show that the failure was due to the formation of notches on the femur plate. These notches act as stress raisers from where the cracks start to propagate. Finally fracture occurred on the femur plate and subsequently, the plate failed.

  20. A case study in nonconformance and performance trend analysis

    NASA Technical Reports Server (NTRS)

    Maloy, Joseph E.; Newton, Coy P.

    1990-01-01

    As part of NASA's effort to develop an agency-wide approach to trend analysis, a pilot nonconformance and performance trending analysis study was conducted on the Space Shuttle auxiliary power unit (APU). The purpose of the study was to (1) demonstrate that nonconformance analysis can be used to identify repeating failures of a specific item (and the associated failure modes and causes) and (2) determine whether performance parameters could be analyzed and monitored to provide an indication of component or system degradation prior to failure. The nonconformance analysis of the APU did identify repeating component failures, which possibly could be reduced if key performance parameters were monitored and analyzed. The performance-trending analysis verified that the characteristics of hardware parameters can be effective in detecting degradation of hardware performance prior to failure.

  1. Failure Analysis of Discrete Damaged Tailored Extension-Shear-Coupled Stiffened Composite Panels

    NASA Technical Reports Server (NTRS)

    Baker, Donald J.

    2005-01-01

    The results of an analytical and experimental investigation of the failure of composite is tiffener panels with extension-shear coupling are presented. This tailored concept, when used in the cover skins of a tiltrotor aircraft wing has the potential for increasing the aeroelastic stability margins and improving the aircraft productivity. The extension-shear coupling is achieved by using unbalanced 45 plies in the skin. The failure analysis of two tailored panel configurations that have the center stringer and adjacent skin severed is presented. Finite element analysis of the damaged panels was conducted using STAGS (STructural Analysis of General Shells) general purpose finite element program that includes a progressive failure capability for laminated composite structures that is based on point-stress analysis, traditional failure criteria, and ply discounting for material degradation. The progressive failure predicted the path of the failure and maximum load capability. There is less than 12 percent difference between the predicted failure load and experimental failure load. There is a good match of the panel stiffness and strength between the progressive failure analysis and the experimental results. The results indicate that the tailored concept would be feasible to use in the wing skin of a tiltrotor aircraft.

  2. Structural Analysis for the American Airlines Flight 587 Accident Investigation: Global Analysis

    NASA Technical Reports Server (NTRS)

    Young, Richard D.; Lovejoy, Andrew E.; Hilburger, Mark W.; Moore, David F.

    2005-01-01

    NASA Langley Research Center (LaRC) supported the National Transportation Safety Board (NTSB) in the American Airlines Flight 587 accident investigation due to LaRC's expertise in high-fidelity structural analysis and testing of composite structures and materials. A Global Analysis Team from LaRC reviewed the manufacturer s design and certification procedures, developed finite element models and conducted structural analyses, and participated jointly with the NTSB and Airbus in subcomponent tests conducted at Airbus in Hamburg, Germany. The Global Analysis Team identified no significant or obvious deficiencies in the Airbus certification and design methods. Analysis results from the LaRC team indicated that the most-likely failure scenario was failure initiation at the right rear main attachment fitting (lug), followed by an unstable progression of failure of all fin-to-fuselage attachments and separation of the VTP from the aircraft. Additionally, analysis results indicated that failure initiates at the final observed maximum fin loading condition in the accident, when the VTP was subjected to loads that were at minimum 1.92 times the design limit load condition for certification. For certification, the VTP is only required to support loads of 1.5 times design limit load without catastrophic failure. The maximum loading during the accident was shown to significantly exceed the certification requirement. Thus, the structure appeared to perform in a manner consistent with its design and certification, and failure is attributed to VTP loads greater than expected.

  3. Failure Analysis of PRDS Pipe in a Thermal Power Plant Boiler

    NASA Astrophysics Data System (ADS)

    Ghosh, Debashis; Ray, Subrata; Mandal, Jiten; Mandal, Nilrudra; Shukla, Awdhesh Kumar

    2018-04-01

    The pressure reducer desuperheater (PRDS) pipeline is used for reducing the pressure and desuperheating of the steam in different auxiliary pipeline. When the PRDS pipeline is failed, the reliability of the boiler is affected. This paper investigates the probable cause/causes of failure of the PRDS tapping line. In that context, visual inspection, outside diameter and wall thickness measurement, chemical analysis, metallographic examination and hardness measurement are conducted as part of the investigative studies. Apart from these tests, mechanical testing and fractographic analysis are also conducted as supplements. Finally, it has been concluded that the PRDS pipeline has mainly failed due to graphitization due to prolonged exposure of the pipe at higher temperature. The improper material used is mainly responsible for premature failure of the pipe.

  4. Development of Decision Making in School-Aged Children and Adolescents: Evidence from Heart Rate and Skin Conductance Analysis

    ERIC Educational Resources Information Center

    Crone, Eveline A.; van der Molen, Maurits W.

    2007-01-01

    Age differences in decision making indicate that children fail to anticipate outcomes of their decisions. Using heart rate and skin conductance analyses, we tested whether developmental changes in decision making are associated with (a) a failure to process outcomes of decisions, or (b) a failure to anticipate future outcomes of decisions.…

  5. Psychophysiology of Aggression, Psychopathy, and Conduct Problems: A Meta-Analysis

    ERIC Educational Resources Information Center

    Lorber, Michael F.

    2004-01-01

    A meta-analysis of 95 studies was conducted to investigate the relations of heart rate (HR) and electrodermal activity (EDA) with aggression, psychopathy, and conduct problems. Analyses revealed a complex constellation of interactive effects, with a failure in some cases of autonomic patterns to generalize across antisocial spectrum behavior…

  6. Refurbishment of Railroad Crossties : A Technical and Economic Analysis

    DOT National Transportation Integrated Search

    1977-12-01

    An analysis of the principal modes of failure for wooden railroad crossties was conducted and an evaluation of the technical and economic feasibility of refurbishing these ties was conducted. Among the principal modes of structural deterioration, onl...

  7. Failure mode and effects analysis drastically reduced potential risks in clinical trial conduct.

    PubMed

    Lee, Howard; Lee, Heechan; Baik, Jungmi; Kim, Hyunjung; Kim, Rachel

    2017-01-01

    Failure mode and effects analysis (FMEA) is a risk management tool to proactively identify and assess the causes and effects of potential failures in a system, thereby preventing them from happening. The objective of this study was to evaluate effectiveness of FMEA applied to an academic clinical trial center in a tertiary care setting. A multidisciplinary FMEA focus group at the Seoul National University Hospital Clinical Trials Center selected 6 core clinical trial processes, for which potential failure modes were identified and their risk priority number (RPN) was assessed. Remedial action plans for high-risk failure modes (RPN >160) were devised and a follow-up RPN scoring was conducted a year later. A total of 114 failure modes were identified with an RPN score ranging 3-378, which was mainly driven by the severity score. Fourteen failure modes were of high risk, 11 of which were addressed by remedial actions. Rescoring showed a dramatic improvement attributed to reduction in the occurrence and detection scores by >3 and >2 points, respectively. FMEA is a powerful tool to improve quality in clinical trials. The Seoul National University Hospital Clinical Trials Center is expanding its FMEA capability to other core clinical trial processes.

  8. Tensile and Laterally Confined Compression Properties of Various 3-Dimensional (3-D) Woven Composites

    DTIC Science & Technology

    2014-11-01

    such as orthogonal (Z- fiber) weave, layer-to-layer, and angle interlock. Figure 1 provides an example of 2 different types of 3-D woven structures...o.~os~~~o. t Deflection (in) (c) 90° Orientation 18 6.4 LCC Test Specimen Failure Analysis LCC posttest failure analysis was conducted

  9. Failure analysis of a Stirling engine heat pipe

    NASA Technical Reports Server (NTRS)

    Moore, Thomas J.; Cairelli, James E.; Khalili, Kaveh

    1989-01-01

    Failure analysis was conducted on a heat pipe from a Stirling Engine test rig which was designed to operate at 1073 K. Premature failure had occurred due to localized overheating at the leading edge of the evaporator fin. It was found that a crack had allowed air to enter the fin and react with the sodium coolant. The origin of the crack was found to be located at the inner surface of the Inconel 600 fin where severe intergranular corrosion had taken place.

  10. Managing heart failure in the long-term care setting: nurses' experiences in Ontario, Canada.

    PubMed

    Strachan, Patricia H; Kaasalainen, Sharon; Horton, Amy; Jarman, Hellen; D'Elia, Teresa; Van Der Horst, Mary-Lou; Newhouse, Ian; Kelley, Mary Lou; McAiney, Carrie; McKelvie, Robert; Heckman, George A

    2014-01-01

    Implementation of heart failure guidelines in long-term care (LTC) settings is challenging. Understanding the conditions of nursing practice can improve management, reduce suffering, and prevent hospital admission of LTC residents living with heart failure. The aim of the study was to understand the experiences of LTC nurses managing care for residents with heart failure. This was a descriptive qualitative study nested in Phase 2 of a three-phase mixed methods project designed to investigate barriers and solutions to implementing the Canadian Cardiovascular Society heart failure guidelines into LTC homes. Five focus groups totaling 33 nurses working in LTC settings in Ontario, Canada, were audiorecorded, then transcribed verbatim, and entered into NVivo9. A complex adaptive systems framework informed this analysis. Thematic content analysis was conducted by the research team. Triangulation, rigorous discussion, and a search for negative cases were conducted. Data were collected between May and July 2010. Nurses characterized their experiences managing heart failure in relation to many influences on their capacity for decision-making in LTC settings: (a) a reactive versus proactive approach to chronic illness; (b) ability to interpret heart failure signs, symptoms, and acuity; (c) compromised information flow; (d) access to resources; and (e) moral distress. Heart failure guideline implementation reflects multiple dynamic influences. Leadership that addresses these factors is required to optimize the conditions of heart failure care and related nursing practice.

  11. FAILURE OF RADIOACTIVE IODINE IN TREATMENT OF HYPERTHYROIDISM

    PubMed Central

    Schneider, David F.; Sonderman, Philip E.; Jones, Michaela F.; Ojomo, Kristin A.; Chen, Herbert; Jaume, Juan C.; Elson, Diane F.; Perlman, Scott B.; Sippel, Rebecca S.

    2015-01-01

    Introduction Persistent or recurrent hyperthyroidism after treatment with radioactive iodine (RAI) is common, and many patients require either additional doses or surgery before they are cured. The purpose of this study was to identify patterns and predictors of failure of RAI in patients with hyperthyroidism. Methods We conducted a retrospective review of patients treated with RAI from 2007–2010. Failure of RAI was defined as receipt of additional dose(s) and/or total thyroidectomy. Using a Cox proportional hazards model, we conducted univariate analysis to identify factors associated with failure of RAI. A final multivariate model was then constructed with significant (p < 0.05) variables from the univariate analysis. Results Of the 325 patients analyzed, 74 patients (22.8%) failed initial RAI treatment. 53 (71.6%) received additional RAI, 13 (17.6%) received additional RAI followed by surgery, and the remaining 8 (10.8%) were cured after thyroidectomy. The percentage of patients who failed decreased in a step-wise fashion as RAI dose increased. Similarly, the incidence of failure increased as the presenting T3 level increased. Sensitivity analysis revealed that RAI doses < 12.5 mCi were associated with failure while initial T3 and free T4 levels of at least 4.5 pg/mL and 2.3 ng/dL, respectively, were associated with failure. In the final multivariate analysis, higher T4 (HR 1.13, 95% CI 1.02–1.26, p=0.02) and methimazole treatment (HR 2.55, 95% CI 1.22–5.33, p=0.01) were associated with failure. Conclusions Laboratory values at presentation can predict which patients with hyperthyroidism are at risk for failing RAI treatment. Higher doses of RAI or surgical referral may prevent the need for repeat RAI in selected patients. PMID:25001092

  12. Failure of radioactive iodine in the treatment of hyperthyroidism.

    PubMed

    Schneider, David F; Sonderman, Philip E; Jones, Michaela F; Ojomo, Kristin A; Chen, Herbert; Jaume, Juan C; Elson, Diane F; Perlman, Scott B; Sippel, Rebecca S

    2014-12-01

    Persistent or recurrent hyperthyroidism after treatment with radioactive iodine (RAI) is common and many patients require either additional doses or surgery before they are cured. The purpose of this study was to identify patterns and predictors of failure of RAI in patients with hyperthyroidism. We conducted a retrospective review of patients treated with RAI from 2007 to 2010. Failure of RAI was defined as receipt of additional dose(s) and/or total thyroidectomy. Using a Cox proportional hazards model, we conducted univariate analysis to identify factors associated with failure of RAI. A final multivariate model was then constructed with significant (p < 0.05) variables from the univariate analysis. Of the 325 patients analyzed, 74 patients (22.8 %) failed initial RAI treatment, 53 (71.6 %) received additional RAI, 13 (17.6 %) received additional RAI followed by surgery, and the remaining 8 (10.8 %) were cured after thyroidectomy. The percentage of patients who failed decreased in a stepwise fashion as RAI dose increased. Similarly, the incidence of failure increased as the presenting T3 level increased. Sensitivity analysis revealed that RAI doses <12.5 mCi were associated with failure while initial T3 and free T4 levels of at least 4.5 pg/mL and 2.3 ng/dL, respectively, were associated with failure. In the final multivariate analysis, higher T4 (hazard ratio [HR] 1.13; 95 % confidence interval [CI] 1.02-1.26; p = 0.02) and methimazole treatment (HR 2.55; 95 % CI 1.22-5.33; p = 0.01) were associated with failure. Laboratory values at presentation can predict which patients with hyperthyroidism are at risk for failing RAI treatment. Higher doses of RAI or surgical referral may prevent the need for repeat RAI in selected patients.

  13. Integrating FMEA in a Model-Driven Methodology

    NASA Astrophysics Data System (ADS)

    Scippacercola, Fabio; Pietrantuono, Roberto; Russo, Stefano; Esper, Alexandre; Silva, Nuno

    2016-08-01

    Failure Mode and Effects Analysis (FMEA) is a well known technique for evaluating the effects of potential failures of components of a system. FMEA demands for engineering methods and tools able to support the time- consuming tasks of the analyst. We propose to make FMEA part of the design of a critical system, by integration into a model-driven methodology. We show how to conduct the analysis of failure modes, propagation and effects from SysML design models, by means of custom diagrams, which we name FMEA Diagrams. They offer an additional view of the system, tailored to FMEA goals. The enriched model can then be exploited to automatically generate FMEA worksheet and to conduct qualitative and quantitative analyses. We present a case study from a real-world project.

  14. [Failure mode and effects analysis (FMEA) of insulin in a mother-child university-affiliated health center].

    PubMed

    Berruyer, M; Atkinson, S; Lebel, D; Bussières, J-F

    2016-01-01

    Insulin is a high-alert drug. The main objective of this descriptive cross-sectional study was to evaluate the risks associated with insulin use in healthcare centers. The secondary objective was to propose corrective measures to reduce the main risks associated with the most critical failure modes in the analysis. We conducted a failure mode and effects analysis (FMEA) in obstetrics-gynecology, neonatology and pediatrics. Five multidisciplinary meetings occurred in August 2013. A total of 44 out of 49 failure modes were analyzed. Nine out of 44 (20%) failure modes were deemed critical, with a criticality score ranging from 540 to 720. Following the multidisciplinary meetings, everybody agreed that an FMEA was a useful tool to identify failure modes and their relative importance. This approach identified many corrective measures. This shared experience increased awareness of safety issues with insulin in our mother-child center. This study identified the main failure modes and associated corrective measures. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  15. The Full Spectrum of Clinical Ethical Issues in Kidney Failure. Findings of a Systematic Qualitative Review.

    PubMed

    Kahrass, Hannes; Strech, Daniel; Mertz, Marcel

    2016-01-01

    When treating patients with kidney failure, unavoidable ethical issues often arise. Current clinical practice guidelines some of them, but lack comprehensive information about the full range of relevant ethical issues in kidney failure. A systematic literature review of such ethical issues supports medical professionalism in nephrology, and offers a solid evidential base for efforts that aim to improve ethical conduct in health care. To identify the full spectrum of clinical ethical issues that can arise for patients with kidney failure in a systematic and transparent manner. A systematic review in Medline (publications in English or German between 2000 and 2014) and Google Books (with no restrictions) was conducted. Ethical issues were identified by qualitative text analysis and normative analysis. The literature review retrieved 106 references that together mentioned 27 ethical issues in clinical care of kidney failure. This set of ethical issues was structured into a matrix consisting of seven major categories and further first and second-order categories. The systematically-derived matrix helps raise awareness and understanding of the complexity of ethical issues in kidney failure. It can be used to identify ethical issues that should be addressed in specific training programs for clinicians, clinical practice guidelines, or other types of policies dealing with kidney failure.

  16. The Full Spectrum of Clinical Ethical Issues in Kidney Failure. Findings of a Systematic Qualitative Review

    PubMed Central

    Kahrass, Hannes; Strech, Daniel; Mertz, Marcel

    2016-01-01

    Background When treating patients with kidney failure, unavoidable ethical issues often arise. Current clinical practice guidelines some of them, but lack comprehensive information about the full range of relevant ethical issues in kidney failure. A systematic literature review of such ethical issues supports medical professionalism in nephrology, and offers a solid evidential base for efforts that aim to improve ethical conduct in health care. Aim To identify the full spectrum of clinical ethical issues that can arise for patients with kidney failure in a systematic and transparent manner. Method A systematic review in Medline (publications in English or German between 2000 and 2014) and Google Books (with no restrictions) was conducted. Ethical issues were identified by qualitative text analysis and normative analysis. Results The literature review retrieved 106 references that together mentioned 27 ethical issues in clinical care of kidney failure. This set of ethical issues was structured into a matrix consisting of seven major categories and further first and second-order categories. Conclusions The systematically-derived matrix helps raise awareness and understanding of the complexity of ethical issues in kidney failure. It can be used to identify ethical issues that should be addressed in specific training programs for clinicians, clinical practice guidelines, or other types of policies dealing with kidney failure. PMID:26938863

  17. Failure mode and effects analysis drastically reduced potential risks in clinical trial conduct

    PubMed Central

    Baik, Jungmi; Kim, Hyunjung; Kim, Rachel

    2017-01-01

    Background Failure mode and effects analysis (FMEA) is a risk management tool to proactively identify and assess the causes and effects of potential failures in a system, thereby preventing them from happening. The objective of this study was to evaluate effectiveness of FMEA applied to an academic clinical trial center in a tertiary care setting. Methods A multidisciplinary FMEA focus group at the Seoul National University Hospital Clinical Trials Center selected 6 core clinical trial processes, for which potential failure modes were identified and their risk priority number (RPN) was assessed. Remedial action plans for high-risk failure modes (RPN >160) were devised and a follow-up RPN scoring was conducted a year later. Results A total of 114 failure modes were identified with an RPN score ranging 3–378, which was mainly driven by the severity score. Fourteen failure modes were of high risk, 11 of which were addressed by remedial actions. Rescoring showed a dramatic improvement attributed to reduction in the occurrence and detection scores by >3 and >2 points, respectively. Conclusions FMEA is a powerful tool to improve quality in clinical trials. The Seoul National University Hospital Clinical Trials Center is expanding its FMEA capability to other core clinical trial processes. PMID:29089745

  18. Failures Analysis of E-Glass Fibre reinforced pipes in Oil and Gas Industry: A Review

    NASA Astrophysics Data System (ADS)

    Bobba, Sujith; Leman, Z.; Zainuddin, E. S.; Sapuan, S. M.

    2017-07-01

    A comprehensive review is conducted on the failures in the field of manufacturing and installation of E-glass fiber reinforced pipes (GFRP). Some of the failures which are mainly encountered after the installation of E-Glass fiber reinforced pipes are the for nation of air bubbles in between the polyester resin layer and the surface film, dispersion of moisture in between the tubing outer and inner layers after installation, heat released in between the layers of E-glass fiber reinforced pipes due to exothermic reaction which in turn results in the formation of cracks on the surface of the pipe. The recent findings and challenges performed in conducting research regarding the deterioration caused in glass fiber reinforced pipes are highlighted and each type of failure that was identified was illustrated with an appropriate high resolution photograph. Performing creep resistance and fatigue analysis are new aspects which are still requited to be analyzed which ave not been stated in the literature which are nominated.

  19. Model-OA wind turbine generator - Failure modes and effects analysis

    NASA Technical Reports Server (NTRS)

    Klein, William E.; Lali, Vincent R.

    1990-01-01

    The results failure modes and effects analysis (FMEA) conducted for wind-turbine generators are presented. The FMEA was performed for the functional modes of each system, subsystem, or component. The single-point failures were eliminated for most of the systems. The blade system was the only exception. The qualitative probability of a blade separating was estimated at level D-remote. Many changes were made to the hardware as a result of this analysis. The most significant change was the addition of the safety system. Operational experience and need to improve machine availability have resulted in subsequent changes to the various systems, which are also reflected in this FMEA.

  20. Report of the NASA Ad Hoc Committee on failure of high strength structural materials

    NASA Technical Reports Server (NTRS)

    Brown, W. F., Jr. (Editor)

    1972-01-01

    An analysis of structural failures that have occurred in NASA programs was conducted. Reports of 231 examples of structural failure were reviewed. Attempts were made to identify those factors which contributed to the failures, and recommendations were formulated for actions which would minimize their effects on future NASA programs. Two classes of factors were identified: (1) those associated with deficiencies in existing materials and structures technology and (2) those attributable to inadequate documentation or communication of that technology.

  1. Failure analysis of storage tank component in LNG regasification unit using fault tree analysis method (FTA)

    NASA Astrophysics Data System (ADS)

    Mulyana, Cukup; Muhammad, Fajar; Saad, Aswad H.; Mariah, Riveli, Nowo

    2017-03-01

    Storage tank component is the most critical component in LNG regasification terminal. It has the risk of failure and accident which impacts to human health and environment. Risk assessment is conducted to detect and reduce the risk of failure in storage tank. The aim of this research is determining and calculating the probability of failure in regasification unit of LNG. In this case, the failure is caused by Boiling Liquid Expanding Vapor Explosion (BLEVE) and jet fire in LNG storage tank component. The failure probability can be determined by using Fault Tree Analysis (FTA). Besides that, the impact of heat radiation which is generated is calculated. Fault tree for BLEVE and jet fire on storage tank component has been determined and obtained with the value of failure probability for BLEVE of 5.63 × 10-19 and for jet fire of 9.57 × 10-3. The value of failure probability for jet fire is high enough and need to be reduced by customizing PID scheme of regasification LNG unit in pipeline number 1312 and unit 1. The value of failure probability after customization has been obtained of 4.22 × 10-6.

  2. [Retrieval and failure analysis of surgical implants in Brazil: the need for proper regulation].

    PubMed

    Azevedo, Cesar R de Farias; Hippert, Eduardo

    2002-01-01

    This paper summarizes several cases of metallurgical failure analysis of surgical implants conducted at the Laboratory of Failure Analysis, Instituto de Pesquisas Tecnológicas (IPT), in Brazil. Failures with two stainless steel femoral compression plates, one stainless steel femoral nail plate, one Ti-6Al-4V alloy maxillary reconstruction plate, and five Nitinol wires were investigated. The results showed that the implants were not in accordance with ISO standards and presented evidence of corrosion-assisted fracture. Furthermore, some of the implants presented manufacturing/processing defects which also contributed to their premature failure. Implantation of materials that are not biocompatible may cause several types of adverse effects in the human body and lead to premature implant failure. A review of prevailing health legislation is needed in Brazil, along with the adoption of regulatory mechanisms to assure the quality of surgical implants on the market, providing for compulsory procedures in the reporting and investigation of surgical implants which have failed in service.

  3. Analysis of middle bearing failure in rotor jet engine using tip-timing and tip-clearance techniques

    NASA Astrophysics Data System (ADS)

    Rzadkowski, R.; Rokicki, E.; Piechowski, L.; Szczepanik, R.

    2016-08-01

    The reported problem is the failure of the middle bearing in an aircraft rotor engine. Tip-timing and tip-clearance and variance analyses are carried out on a compressor rotor blade in the seventh stage above the middle bearing. The experimental analyses concern both an aircraft engine with a middle bearing in good working order and an engine with a damaged middle bearing. A numerical analysis of seventh stage blade free vibration is conducted to explain the experimental results. This appears to be an effective method of predicting middle bearing failure. The results show that variance first increases in the initial stages of bearing failure, but then starts to decrease and stabilize, and then again decrease shortly before complete bearing failure.

  4. An analysis of fiber-matrix interface failure stresses for a range of ply stress states

    NASA Technical Reports Server (NTRS)

    Crews, J. H.; Naik, R. A.; Lubowinski, S. J.

    1993-01-01

    A graphite/bismaleimide laminate was prepared without the usual fiber treatment and was tested over a wide range of stress states to measure its ply cracking strength. These tests were conducted using off-axis flexure specimens and produced fiber-matrix interface failure data over a correspondingly wide range of interface stress states. The absence of fiber treatment, weakened the fiber-matrix interfaces and allowed these tests to be conducted at load levels that did not yield the matrix. An elastic micromechanics computer code was used to calculate the fiber-matrix interface stresses at failure. Two different fiber-array models (square and diamond) were used in these calculations to analyze the effects of fiber arrangement as well as stress state on the critical interface stresses at failure. This study showed that both fiber-array models were needed to analyze interface stresses over the range of stress states. A linear equation provided a close fit to these critical stress combinations and, thereby, provided a fiber-matrix interface failure criterion. These results suggest that prediction procedures for laminate ply cracking can be based on micromechanics stress analyses and appropriate fiber-matrix interface failure criteria. However, typical structural laminates may require elastoplastic stress analysis procedures that account for matrix yielding, especially for shear-dominated ply stress states.

  5. Identifying the latent failures underpinning medication administration errors: an exploratory study.

    PubMed

    Lawton, Rebecca; Carruthers, Sam; Gardner, Peter; Wright, John; McEachan, Rosie R C

    2012-08-01

    The primary aim of this article was to identify the latent failures that are perceived to underpin medication errors. The study was conducted within three medical wards in a hospital in the United Kingdom. The study employed a cross-sectional qualitative design. Interviews were conducted with 12 nurses and eight managers. Interviews were transcribed and subject to thematic content analysis. A two-step inter-rater comparison tested the reliability of the themes. Ten latent failures were identified based on the analysis of the interviews. These were ward climate, local working environment, workload, human resources, team communication, routine procedures, bed management, written policies and procedures, supervision and leadership, and training. The discussion focuses on ward climate, the most prevalent theme, which is conceptualized here as interacting with failures in the nine other organizational structures and processes. This study is the first of its kind to identify the latent failures perceived to underpin medication errors in a systematic way. The findings can be used as a platform for researchers to test the impact of organization-level patient safety interventions and to design proactive error management tools and incident reporting systems in hospitals. © Health Research and Educational Trust.

  6. Structural Analysis of the Right Rear Lug of American Airlines Flight 587

    NASA Technical Reports Server (NTRS)

    Raju, Ivatury S.; Glaessgen, Edward H.; Mason, Brian H.; Krishnamurthy, Thiagarajan; Davila, Carlos G.

    2006-01-01

    A detailed finite element analysis of the right rear lug of the American Airlines Flight 587 - Airbus A300-600R was performed as part of the National Transportation Safety Board s failure investigation of the accident that occurred on November 12, 2001. The loads experienced by the right rear lug are evaluated using global models of the vertical tail, local models near the right rear lug, and a global-local analysis procedure. The right rear lug was analyzed using two modeling approaches. In the first approach, solid-shell type modeling is used, and in the second approach, layered-shell type modeling is used. The solid-shell and the layered-shell modeling approaches were used in progressive failure analyses (PFA) to determine the load, mode, and location of failure in the right rear lug under loading representative of an Airbus certification test conducted in 1985 (the 1985-certification test). Both analyses were in excellent agreement with each other on the predicted failure loads, failure mode, and location of failure. The solid-shell type modeling was then used to analyze both a subcomponent test conducted by Airbus in 2003 (the 2003-subcomponent test) and the accident condition. Excellent agreement was observed between the analyses and the observed failures in both cases. The moment, Mx (moment about the fuselage longitudinal axis), has significant effect on the failure load of the lugs. Higher absolute values of Mx give lower failure loads. The predicted load, mode, and location of the failure of the 1985- certification test, 2003-subcomponent test, and the accident condition are in very good agreement. This agreement suggests that the 1985-certification and 2003-subcomponent tests represent the accident condition accurately. The failure mode of the right rear lug for the 1985-certification test, 2003-subcomponent test, and the accident load case is identified as a cleavage-type failure. For the accident case, the predicted failure load for the right rear lug from the PFA is greater than 1.98 times the limit load of the lugs.

  7. Regression analysis of clustered failure time data with informative cluster size under the additive transformation models.

    PubMed

    Chen, Ling; Feng, Yanqin; Sun, Jianguo

    2017-10-01

    This paper discusses regression analysis of clustered failure time data, which occur when the failure times of interest are collected from clusters. In particular, we consider the situation where the correlated failure times of interest may be related to cluster sizes. For inference, we present two estimation procedures, the weighted estimating equation-based method and the within-cluster resampling-based method, when the correlated failure times of interest arise from a class of additive transformation models. The former makes use of the inverse of cluster sizes as weights in the estimating equations, while the latter can be easily implemented by using the existing software packages for right-censored failure time data. An extensive simulation study is conducted and indicates that the proposed approaches work well in both the situations with and without informative cluster size. They are applied to a dental study that motivated this study.

  8. Failure mode and effects analysis and fault tree analysis of surface image guided cranial radiosurgery.

    PubMed

    Manger, Ryan P; Paxton, Adam B; Pawlicki, Todd; Kim, Gwe-Ya

    2015-05-01

    Surface image guided, Linac-based radiosurgery (SIG-RS) is a modern approach for delivering radiosurgery that utilizes optical stereoscopic imaging to monitor the surface of the patient during treatment in lieu of using a head frame for patient immobilization. Considering the novelty of the SIG-RS approach and the severity of errors associated with delivery of large doses per fraction, a risk assessment should be conducted to identify potential hazards, determine their causes, and formulate mitigation strategies. The purpose of this work is to investigate SIG-RS using the combined application of failure modes and effects analysis (FMEA) and fault tree analysis (FTA), report on the effort required to complete the analysis, and evaluate the use of FTA in conjunction with FMEA. A multidisciplinary team was assembled to conduct the FMEA on the SIG-RS process. A process map detailing the steps of the SIG-RS was created to guide the FMEA. Failure modes were determined for each step in the SIG-RS process, and risk priority numbers (RPNs) were estimated for each failure mode to facilitate risk stratification. The failure modes were ranked by RPN, and FTA was used to determine the root factors contributing to the riskiest failure modes. Using the FTA, mitigation strategies were formulated to address the root factors and reduce the risk of the process. The RPNs were re-estimated based on the mitigation strategies to determine the margin of risk reduction. The FMEA and FTAs for the top two failure modes required an effort of 36 person-hours (30 person-hours for the FMEA and 6 person-hours for two FTAs). The SIG-RS process consisted of 13 major subprocesses and 91 steps, which amounted to 167 failure modes. Of the 91 steps, 16 were directly related to surface imaging. Twenty-five failure modes resulted in a RPN of 100 or greater. Only one of these top 25 failure modes was specific to surface imaging. The riskiest surface imaging failure mode had an overall RPN-rank of eighth. Mitigation strategies for the top failure mode decreased the RPN from 288 to 72. Based on the FMEA performed in this work, the use of surface imaging for monitoring intrafraction position in Linac-based stereotactic radiosurgery (SRS) did not greatly increase the risk of the Linac-based SRS process. In some cases, SIG helped to reduce the risk of Linac-based RS. The FMEA was augmented by the use of FTA since it divided the failure modes into their fundamental components, which simplified the task of developing mitigation strategies.

  9. Advanced composites structural concepts and materials technologies for primary aircraft structures: Structural response and failure analysis

    NASA Technical Reports Server (NTRS)

    Dorris, William J.; Hairr, John W.; Huang, Jui-Tien; Ingram, J. Edward; Shah, Bharat M.

    1992-01-01

    Non-linear analysis methods were adapted and incorporated in a finite element based DIAL code. These methods are necessary to evaluate the global response of a stiffened structure under combined in-plane and out-of-plane loading. These methods include the Arc Length method and target point analysis procedure. A new interface material model was implemented that can model elastic-plastic behavior of the bond adhesive. Direct application of this method is in skin/stiffener interface failure assessment. Addition of the AML (angle minus longitudinal or load) failure procedure and Hasin's failure criteria provides added capability in the failure predictions. Interactive Stiffened Panel Analysis modules were developed as interactive pre-and post-processors. Each module provides the means of performing self-initiated finite elements based analysis of primary structures such as a flat or curved stiffened panel; a corrugated flat sandwich panel; and a curved geodesic fuselage panel. This module brings finite element analysis into the design of composite structures without the requirement for the user to know much about the techniques and procedures needed to actually perform a finite element analysis from scratch. An interactive finite element code was developed to predict bolted joint strength considering material and geometrical non-linearity. The developed method conducts an ultimate strength failure analysis using a set of material degradation models.

  10. Destructive Single-Event Effects in Diodes

    NASA Technical Reports Server (NTRS)

    Casey, Megan C.; Lauenstein, Jean-Marie; Campola, Michael J.; Wilcox, Edward P.; Phan, Anthony M.; Label, Kenneth A.

    2017-01-01

    In this work, we discuss the observed single-event effects in a variety of types of diodes. In addition, we conduct failure analysis on several Schottky diodes that were heavy-ion irradiated. High- and low-magnitude optical microscope images, infrared camera images, and scanning electron microscope images are used to identify and describe the failure locations.

  11. Risk of heart failure and edema associated with the use of pregabalin: a systematic review.

    PubMed

    Ho, Joanne M; Tricco, Andrea C; Perrier, Laure; Chen, Maggie; Juurlink, David N; Straus, Sharon E

    2013-05-04

    Pregabalin is used in the treatment of postherpetic neuralgia, diabetic neuropathic pain, partial seizures, anxiety disorders and fibromyalgia. Recognized adverse effects associated with its use include cognitive impairment, somnolence and dizziness. Heart failure associated with pregabalin has been described, however the strength of this association has not been well characterized. To examine this further, we will conduct a systematic review of the risk of heart failure and edema associated with use of pregabalin. We will include all studies (experimental, quasi-experimental, observational, case series/reports, drug regulatory reports) that examine the use of pregabalin compared to placebo, gabapentin or conventional care. Our primary outcome is heart failure and the secondary outcomes include edema and weight gain. We will search electronic databases (MEDLINE, EMBASE, Cochrane Central Register of Controlled Trials), and grey literature sources (trial registries, conference abstracts) to identify relevant studies. To ensure literature saturation, we will contact drug manufacturers, conduct forward citation searching, and scan the reference lists of key articles and included studies. We will not restrict inclusion by language or publication status.Two reviewers will screen citations (titles and abstracts) and full-text articles, conduct data abstraction, and appraise risk of bias. Random-effects meta-analysis will be conducted if the studies are deemed heterogeneous in terms of clinical, statistical and methodological factors but still suitable for meta-analysis. The results of this review will assist physicians to better appreciate pregabalin's risk for edema or congestive heart failure and will be pertinent to the thousands of patients worldwide who are administered this medication.Our protocol was registered in the PROSPERO database (CRD42012002948).

  12. How Analysis Informs Regulation:Success and Failure of ...

    EPA Pesticide Factsheets

    How Analysis Informs Regulation:Success and Failure of Evolving Approaches to Polyfluoroalkyl Acid Contamination The National Exposure Research Laboratory (NERL) Human Exposure and Atmospheric Sciences Division (HEASD) conducts research in support of EPA mission to protect human health and the environment. HEASD research program supports Goal 1 (Clean Air) and Goal 4 (Healthy People) of EPA strategic plan. More specifically, our division conducts research to characterize the movement of pollutants from the source to contact with humans. Our multidisciplinary research program produces Methods, Measurements, and Models to identify relationships between and characterize processes that link source emissions, environmental concentrations, human exposures, and target-tissue dose. The impact of these tools is improved regulatory programs and policies for EPA.

  13. A study of discrete control signal fault conditions in the shuttle DPS

    NASA Technical Reports Server (NTRS)

    Reddi, S. S.; Retter, C. T.

    1976-01-01

    An analysis of the effects of discrete failures on the data processing subsystem is presented. A functional description of each discrete together with a list of software modules that use this discrete are included. A qualitative description of the consequences that may ensue due to discrete failures is given followed by a probabilistic reliability analysis of the data processing subsystem. Based on the investigation conducted, recommendations were made to improve the reliability of the subsystem.

  14. Analysis of the STS-126 Flow Control Valve Structural-Acoustic Coupling Failure

    NASA Technical Reports Server (NTRS)

    Jones, Trevor M.; Larko, Jeffrey M.; McNelis, Mark E.

    2010-01-01

    During the Space Transportation System mission STS-126, one of the main engine's flow control valves incurred an unexpected failure. A section of the valve broke off during liftoff. It is theorized that an acoustic mode of the flowing fuel, coupled with a structural mode of the valve, causing a high cycle fatigue failure. This report documents the analysis efforts conducted in an attempt to verify this theory. Hand calculations, computational fluid dynamics, and finite element methods are all implemented and analyses are performed using steady-state methods in addition to transient analysis methods. The conclusion of the analyses is that there is a critical acoustic mode that aligns with a structural mode of the valve

  15. Practical, transparent prospective risk analysis for the clinical laboratory.

    PubMed

    Janssens, Pim Mw

    2014-11-01

    Prospective risk analysis (PRA) is an essential element in quality assurance for clinical laboratories. Practical approaches to conducting PRA in laboratories, however, are scarce. On the basis of the classical Failure Mode and Effect Analysis method, an approach to PRA was developed for application to key laboratory processes. First, the separate, major steps of the process under investigation are identified. Scores are then given for the Probability (P) and Consequence (C) of predefined types of failures and the chances of Detecting (D) these failures. Based on the P and C scores (on a 10-point scale), an overall Risk score (R) is calculated. The scores for each process were recorded in a matrix table. Based on predetermined criteria for R and D, it was determined whether a more detailed analysis was required for potential failures and, ultimately, where risk-reducing measures were necessary, if any. As an illustration, this paper presents the results of the application of PRA to our pre-analytical and analytical activities. The highest R scores were obtained in the stat processes, the most common failure type in the collective process steps was 'delayed processing or analysis', the failure type with the highest mean R score was 'inappropriate analysis' and the failure type most frequently rated as suboptimal was 'identification error'. The PRA designed is a useful semi-objective tool to identify process steps with potential failures rated as risky. Its systematic design and convenient output in matrix tables makes it easy to perform, practical and transparent. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  16. Laser engravings as reason for mechanical failure of titanium-alloyed total hip stems.

    PubMed

    Kluess, Daniel; Steinhauser, Erwin; Joseph, Micheal; Koch, Ursula; Ellenrieder, Martin; Mittelmeier, Wolfram; Bader, Rainer

    2015-07-01

    Two revisions of broken β-titanium total hip stems had to be performed in our hospital after 2 and 4 years in situ. Since both fractures were located at the level of a laser engraving, a failure analysis was conducted. Both retrieved hip stems were disinfected and collected in our retrieval database after patient's signed agreement. Each fragment was macroscopically photographed. Fracture surfaces were analyzed using scanning electron microscopy (SEM). Quantification of element content was conducted using energy dispersive X-ray (EDX) analysis. Both stems show fatigue fracture, as displayed by the lines of rest on the fracture surface. The origin of fracture was identified directly at the laser engraving of the company logo at both stems by means of SEM. The EDX analysis showed an oxygen level beneath the laser engraving about twice as high as in the substrate, causing material embrittlement. Laser engravings need to be reduced to a minimum of necessary information, and should be placed at locations with minimum mechanical load. Biomechanical analyses are recommended to identify less loaded areas in implant components to avoid such implant failures.

  17. Proposal on How To Conduct a Biopharmaceutical Process Failure Mode and Effect Analysis (FMEA) as a Risk Assessment Tool.

    PubMed

    Zimmermann, Hartmut F; Hentschel, Norbert

    2011-01-01

    With the publication of the quality guideline ICH Q9 "Quality Risk Management" by the International Conference on Harmonization, risk management has already become a standard requirement during the life cycle of a pharmaceutical product. Failure mode and effect analysis (FMEA) is a powerful risk analysis tool that has been used for decades in mechanical and electrical industries. However, the adaptation of the FMEA methodology to biopharmaceutical processes brings about some difficulties. The proposal presented here is intended to serve as a brief but nevertheless comprehensive and detailed guideline on how to conduct a biopharmaceutical process FMEA. It includes a detailed 1-to-10-scale FMEA rating table for occurrence, severity, and detectability of failures that has been especially designed for typical biopharmaceutical processes. The application for such a biopharmaceutical process FMEA is widespread. It can be useful whenever a biopharmaceutical manufacturing process is developed or scaled-up, or when it is transferred to a different manufacturing site. It may also be conducted during substantial optimization of an existing process or the development of a second-generation process. According to their resulting risk ratings, process parameters can be ranked for importance and important variables for process development, characterization, or validation can be identified. Health authorities around the world ask pharmaceutical companies to manage risk during development and manufacturing of pharmaceuticals. The so-called failure mode and effect analysis (FMEA) is an established risk analysis tool that has been used for decades in mechanical and electrical industries. However, the adaptation of the FMEA methodology to pharmaceutical processes that use modern biotechnology (biopharmaceutical processes) brings about some difficulties, because those biopharmaceutical processes differ from processes in mechanical and electrical industries. The proposal presented here explains how a biopharmaceutical process FMEA can be conducted. It includes a detailed 1-to-10-scale FMEA rating table for occurrence, severity, and detectability of failures that has been especially designed for typical biopharmaceutical processes. With the help of this guideline, different details of the manufacturing process can be ranked according to their potential risks, and this can help pharmaceutical companies to identify aspects with high potential risks and to react accordingly to improve the safety of medicines.

  18. A Selection of Composites Simulation Practices at NASA Langley Research Center

    NASA Technical Reports Server (NTRS)

    Ratcliffe, James G.

    2007-01-01

    One of the major areas of study at NASA Langley Research Center is the development of technologies that support the use of advanced composite materials in aerospace applications. Amongst the supporting technologies are analysis tools used to simulate the behavior of these materials. This presentation will discuss a number of examples of analysis tools and simulation practices conducted at NASA Langley. The presentation will include examples of damage tolerance analyses for both interlaminar and intralaminar failure modes. Tools for modeling interlaminar failure modes include fracture mechanics and cohesive methods, whilst tools for modeling intralaminar failure involve the development of various progressive failure analyses. Other examples of analyses developed at NASA Langley include a thermo-mechanical model of an orthotropic material and the simulation of delamination growth in z-pin reinforced laminates.

  19. Failure Analysis of a Complex Learning Framework Incorporating Multi-Modal and Semi-Supervised Learning

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pullum, Laura L; Symons, Christopher T

    2011-01-01

    Machine learning is used in many applications, from machine vision to speech recognition to decision support systems, and is used to test applications. However, though much has been done to evaluate the performance of machine learning algorithms, little has been done to verify the algorithms or examine their failure modes. Moreover, complex learning frameworks often require stepping beyond black box evaluation to distinguish between errors based on natural limits on learning and errors that arise from mistakes in implementation. We present a conceptual architecture, failure model and taxonomy, and failure modes and effects analysis (FMEA) of a semi-supervised, multi-modal learningmore » system, and provide specific examples from its use in a radiological analysis assistant system. The goal of the research described in this paper is to provide a foundation from which dependability analysis of systems using semi-supervised, multi-modal learning can be conducted. The methods presented provide a first step towards that overall goal.« less

  20. Investigation on Flexure Test of Composite Beam of Repair Materials and Substrate Concrete for Durable Repair

    NASA Astrophysics Data System (ADS)

    Pattnaik, Rashmi R.; Rangaraju, Prasada Rao

    2014-12-01

    An experimental study was conducted on composite beam of repair materials and substrate concrete to investigate the failures of concrete repair due to differences in strength of repair materials and substrate concrete. In this investigation the flexural strength, load-deflection curves and failure patterns of the composite beam specimens are studied for the durability of the concrete repair. Flexure test was conducted to simulate tensile stress in the concrete repair material. Compressive strength and split tensile strength of the repair materials and substrate concrete are investigated to aid in the analysis of the concrete repair. It was observed that the repair materials of higher compressive strength than the substrate concrete are causing an incompatible failure in the concrete repair.

  1. How to make the most of failure mode and effect analysis.

    PubMed

    Stalhandske, Erik; DeRosier, Joseph; Patail, Bryanne; Gosbee, John

    2003-01-01

    Current accreditation standards issued by the Joint Commission for the Accreditation of Healthcare Organizations (JCAHO) require hospitals to carry out a proactive risk assessment on at least 1 high-risk activity each year for each accredited program. Because hospital risk managers and patient safety managers generally do not have the knowledge or level of comfort for conducting a proactive risk assessment, they will appreciate the expertise offered by biomedical equipment technicians (BMETs), occupational safety and health professionals, and others. The skills that have been developed by BMETs and others while conducting job safety analyses or failure mode effect analysis can now be applied to a health care proactive analysis. This article touches on the Health Care Failure Mode and Effect Analysis (HFMEA) model that the Department of Veterans Affairs (VA) National Center for Patient Safety developed for proactive risk assessment within the health care community. The goal of this article is to enlighten BMETs and others on the growth of proactive risk assessment within health care and also on the support documents and materials produced by the VA. For additional information on HFMEA, visit the VA website at www.patientsafety.gov/HFMEA.html.

  2. Does Bruxism Contribute to Dental Implant Failure? A Systematic Review and Meta-Analysis.

    PubMed

    Zhou, Yi; Gao, Jinxia; Luo, Le; Wang, Yining

    2016-04-01

    Bruxism was usually considered as a contraindication for oral implanting. The causal relationship between bruxism and dental implant failure was remained controversial in existing literatures. This meta-analysis was performed to investigate the relationship between them. This review conducted an electronic systematic literature search in MEDLINE (PubMed) and EmBase in November 2013 without time and language restrictions. Meanwhile, a hand searching for all the relevant references of included studies was also conducted. Study information extraction and methodological quality assessments were accomplished by two reviewers independently. A discussion ensued if any disagreement occurred, and unresolved issues were solved by consulting a third reviewer. Methodological quality was assessed by using the Newcastle-Ottawa Scale tool. Odds ratio (OR) with 95% confidence interval (CI) was pooled to estimate the relative effect of bruxism on dental implant failures. Fixed effects model was used initially; if the heterogeneity was high, random effects model was chosen for meta-analysis. Statistical analyses were carried out by using Review Manager 5.1. In this meta-analysis review, extracted data were classified into two groups based on different units. Units were based on the number of prostheses (group A) and the number of patients (group B). In group A, the total pooled OR of bruxers versus nonbruxers for all subgroups was 4.72 (95% CI: 2.66-8.36, p = .07). In group B, the total pooled OR of bruxers versus nonbruxers for all subgroups was 3.83 (95% CI: 2.12-6.94, p = .22). This meta-analysis was performed to evaluate the relationship between bruxism and dental implant failure. In contrast to nonbruxers, prostheses in bruxers had a higher failure rate. It suggests that bruxism is a contributing factor of causing the occurrence of dental implant technical/biological complications and plays a role in dental implant failure. © 2015 Wiley Periodicals, Inc.

  3. Fatigue crack growth in an aluminum alloy-fractographic study

    NASA Astrophysics Data System (ADS)

    Salam, I.; Muhammad, W.; Ejaz, N.

    2016-08-01

    A two-fold approach was adopted to understand the fatigue crack growth process in an Aluminum alloy; fatigue crack growth test of samples and analysis of fractured surfaces. Fatigue crack growth tests were conducted on middle tension M(T) samples prepared from an Aluminum alloy cylinder. The tests were conducted under constant amplitude loading at R ratio 0.1. The stress applied was from 20,30 and 40 per cent of the yield stress of the material. The fatigue crack growth data was recorded. After fatigue testing, the samples were subjected to detailed scanning electron microscopic (SEM) analysis. The resulting fracture surfaces were subjected to qualitative and quantitative fractographic examinations. Quantitative fracture analysis included an estimation of crack growth rate (CGR) in different regions. The effect of the microstructural features on fatigue crack growth was examined. It was observed that in stage II (crack growth region), the failure mode changes from intergranular to transgranular as the stress level increases. In the region of intergranular failure the localized brittle failure was observed and fatigue striations are difficult to reveal. However, in the region of transgranular failure the crack path is independent of the microstructural features. In this region, localized ductile failure mode was observed and well defined fatigue striations were present in the wake of fatigue crack. The effect of interaction of growing fatigue crack with microstructural features was not substantial. The final fracture (stage III) was ductile in all the cases.

  4. Analysis of Navy radome failure problems

    NASA Technical Reports Server (NTRS)

    Tatnall, G. J.; Foulke, K.

    1974-01-01

    A survey of radome failure problems in military aircraft under actual operating conditions was conducted. The aircraft were operating from aircraft carriers in the Pacific Ocean. Critical problem areas were identified and a plan was developed for failure prevention. The development and application of repair kits for correcting the erosion damage are reported. It is stated that the rain erosion damage survey established a strong justification for qualification testing of all materials and designs which may have questionable life expectancy on the aircraft.

  5. Local-global analysis of crack growth in continuously reinfoced ceramic matrix composites

    NASA Technical Reports Server (NTRS)

    Ballarini, Roberto; Ahmed, Shamim

    1989-01-01

    This paper describes the development of a mathematical model for predicting the strength and micromechanical failure characteristics of continuously reinforced ceramic matrix composites. The local-global analysis models the vicinity of a propagating crack tip as a local heterogeneous region (LHR) consisting of spring-like representation of the matrix, fibers and interfaces. Parametric studies are conducted to investigate the effects of LHR size, component properties, and interface conditions on the strength and sequence of the failure processes in the unidirectional composite system.

  6. Advantage of the modified Lunn-McNeil technique over Kalbfleisch-Prentice technique in competing risks

    NASA Astrophysics Data System (ADS)

    Lukman, Iing; Ibrahim, Noor A.; Daud, Isa B.; Maarof, Fauziah; Hassan, Mohd N.

    2002-03-01

    Survival analysis algorithm is often applied in the data mining process. Cox regression is one of the survival analysis tools that has been used in many areas, and it can be used to analyze the failure times of aircraft crashed. Another survival analysis tool is the competing risks where we have more than one cause of failure acting simultaneously. Lunn-McNeil analyzed the competing risks in the survival model using Cox regression with censored data. The modified Lunn-McNeil technique is a simplify of the Lunn-McNeil technique. The Kalbfleisch-Prentice technique is involving fitting models separately from each type of failure, treating other failure types as censored. To compare the two techniques, (the modified Lunn-McNeil and Kalbfleisch-Prentice) a simulation study was performed. Samples with various sizes and censoring percentages were generated and fitted using both techniques. The study was conducted by comparing the inference of models, using Root Mean Square Error (RMSE), the power tests, and the Schoenfeld residual analysis. The power tests in this study were likelihood ratio test, Rao-score test, and Wald statistics. The Schoenfeld residual analysis was conducted to check the proportionality of the model through its covariates. The estimated parameters were computed for the cause-specific hazard situation. Results showed that the modified Lunn-McNeil technique was better than the Kalbfleisch-Prentice technique based on the RMSE measurement and Schoenfeld residual analysis. However, the Kalbfleisch-Prentice technique was better than the modified Lunn-McNeil technique based on power tests measurement.

  7. Study of twenty preparations of human albumin solution which failed in quality control testing due to elevated sodium content, a poor internal quality control at manufacturing unit.

    PubMed

    Prasad, J P; Madhu, Y; Singh, Surinder; Soni, G R; Agnihotri, N; Singh, Varsha; Kumar, Pradeep; Jain, Nidhi; Prakash, Anu; Singh, Varun

    2016-11-01

    Current study is conducted in our laboratory due to failure in quality control testing of twenty batches of Human Albumin solution in which sodium content is higher than the prescribed limit. These batches are received in short duration from indigenous manufacturer and is the first incident of failure of Human albumin preparation in sodium content of manufacturer. On request of manufacturer, study is conducted to rule out the cause. Repeat testing of each out of specification batch is conducted and a trend analysis is drawn between our findings and manufacturer's results, also study of trend analysis of manufacturer for the last one year. Trend analysis data indicated towards poor consistency of batches with major shift at various time intervals in sodium content of human albumin preparation. Further analysis rule out that non-traceable quality of standard used in the internal quality control testing by manufacturer is the root cause of the problem. Copyright © 2016 International Alliance for Biological Standardization. Published by Elsevier Ltd. All rights reserved.

  8. Response of Honeycomb Core Sandwich Panel with Minimum Gage GFRP Face-Sheets to Compression Loading After Impact

    NASA Technical Reports Server (NTRS)

    McQuigg, Thomas D.; Kapania, Rakesh K.; Scotti, Stephen J.; Walker, Sandra P.

    2011-01-01

    A compression after impact study has been conducted to determine the residual strength of three sandwich panel constructions with two types of thin glass fiber reinforced polymer face-sheets and two hexagonal honeycomb Nomex core densities. Impact testing is conducted to first determine the characteristics of damage resulting from various impact energy levels. Two modes of failure are found during compression after impact tests with the density of the core precipitating the failure mode present for a given specimen. A finite element analysis is presented for prediction of the residual compressive strength of the impacted specimens. The analysis includes progressive damage modeling in the face-sheets. Preliminary analysis results were similar to the experimental results; however, a higher fidelity core material model is expected to improve the correlation.

  9. Health economic evaluation of patients treated for nosocomial pneumonia caused by methicillin-resistant Staphylococcus aureus: secondary analysis of a multicenter randomized clinical trial of vancomycin and linezolid.

    PubMed

    Niederman, Michael S; Chastre, Jean; Solem, Caitlyn T; Wan, Yin; Gao, Xin; Myers, Daniela E; Haider, Seema; Li, Jim Z; Stephens, Jennifer M

    2014-09-01

    Results from studies comparing health care resource use (HCRU), costs of treatment, and cost-effectiveness of linezolid compared with vancomycin therapy in the treatment of hospitalized patients with methicillin-resistant Staphylococcus aureus (MRSA) nosocomial pneumonia are limited in the published literature. We therefore conducted an analysis to compare the HCRU, costs of treatment, and cost-effectiveness of linezolid compared with vancomycin in the treatment of hospitalized patients with MRSA nosocomial pneumonia using data from a Phase IV clinical trial. The economic effect of moderate to severe adverse events (MSAEs) and the development of renal failure were also evaluated. We performed a post hoc analysis of data from a Phase IV, double-blind, randomized, comparator-controlled, multicenter trial that compared linezolid and vancomycin treatment in patients with MRSA nosocomial pneumonia. HCRU and costs were compared based on treatment, development of MSAEs, and development of renal failure using data from the modified intent-to-treat population. Predictors of costs were evaluated using generalized linear models. A piggyback cost-effectiveness analysis was conducted to assess the incremental cost-effectiveness ratio of linezolid versus vancomycin, given the significantly higher clinical success of linezolid compared with vancomycin found in the trial. Overall, HCRU and costs were similar between the linezolid and vancomycin treatment groups; drug costs were significantly higher and dialysis costs significantly lower for linezolid- compared with vancomycin-treated patients. Total treatment costs were approximately $8000 higher (P = .046) for patients who developed renal failure compared with those who did not. Renal failure occurred more commonly in patients randomized to receive vancomycin (15%) compared with linezolid (4%; P < .001). Region, ventilator-associated pneumonia, clinical failure, and development of renal failure were associated with significantly higher total costs. The point estimate incremental cost-effectiveness ratio for linezolid compared with vancomycin was $16,516 per treatment success, with linezolid dominant in 24% and dominated in <2% of bootstrapped samples. This phase 4 clinical trial conducted in patients with MRSA-confirmed nosocomial pneumonia reveals that linezolid- compared with vancomycin-treated patients had similar HCRU and total overall costs. Fewer patients developed renal failure during the study while taking linezolid compared with vancomycin, and patients with a documented MSAE or renal failure had increased HCRU and costs. In summary, linezolid may be a cost-effective treatment strategy in MRSA-confirmed nosocomial pneumonia. Copyright © 2014 Elsevier HS Journals, Inc. All rights reserved.

  10. The Range Safety Debris Catalog Analysis in Preparation for the Pad Abort One Flight Test

    NASA Technical Reports Server (NTRS)

    Kutty, Prasad M.; Pratt, William D.

    2010-01-01

    The Pad Abort One flight test of the Orion Abort Flight Test Program is currently under development with the goal of demonstrating the capability of the Launch Abort System. In the event of a launch failure, this system will propel the Crew Exploration Vehicle to safety. An essential component of this flight test is range safety, which ensures the security of range assets and personnel. A debris catalog analysis was done as part of a range safety data package delivered to the White Sands Missile Range in New Mexico where the test will be conducted. The analysis discusses the consequences of an overpressurization of the Abort Motor. The resulting structural failure was assumed to create a debris field of vehicle fragments that could potentially pose a hazard to the range. A statistical model was used to assemble the debris catalog of potential propellant fragments. Then, a thermodynamic, energy balance model was applied to the system in order to determine the imparted velocity to these propellant fragments. This analysis was conducted at four points along the flight trajectory to better understand the failure consequences over the entire flight. The methods used to perform this analysis are outlined in detail and the corresponding results are presented and discussed.

  11. Evaluation of Acoustic Emission NDE of Composite Crew Module Service Module/Alternate Launch Abort System (CCM SM/ALAS) Test Article Failure Tests

    NASA Technical Reports Server (NTRS)

    Horne, Michael R.; Madaras, Eric I.

    2010-01-01

    Failure tests of CCM SM/ALAS (Composite Crew Module Service Module / Alternate Launch Abort System) composite panels were conducted during July 10, 2008 and July 24, 2008 at Langley Research Center. This is a report of the analysis of the Acoustic Emission (AE) data collected during those tests.

  12. The Lived Experience of Heart Failure at the End of Life: A Systematic Literature Review

    ERIC Educational Resources Information Center

    Hopp, Faith Pratt; Thornton, Nancy; Martin, Lindsey

    2010-01-01

    The growing number of older adults with heart failure (HF) suggests the need for more information about how people with this condition experience their illness and strategies for coping with this condition. To address this need, the authors conducted a systematic review of the literature and an in-depth, thematic analysis of qualitative…

  13. DEPEND - A design environment for prediction and evaluation of system dependability

    NASA Technical Reports Server (NTRS)

    Goswami, Kumar K.; Iyer, Ravishankar K.

    1990-01-01

    The development of DEPEND, an integrated simulation environment for the design and dependability analysis of fault-tolerant systems, is described. DEPEND models both hardware and software components at a functional level, and allows automatic failure injection to assess system performance and reliability. It relieves the user of the work needed to inject failures, maintain statistics, and output reports. The automatic failure injection scheme is geared toward evaluating a system under high stress (workload) conditions. The failures that are injected can affect both hardware and software components. To illustrate the capability of the simulator, a distributed system which employs a prediction-based, dynamic load-balancing heuristic is evaluated. Experiments were conducted to determine the impact of failures on system performance and to identify the failures to which the system is especially susceptible.

  14. Compression failure mechanisms of uni-ply composite plates with a circular cutout

    NASA Technical Reports Server (NTRS)

    Khamseh, A. R.; Waas, A. M.

    1992-01-01

    The effect of circular-hole size on the failure mode of uniply graphite-epoxy composite plates is investigated experimentally and analytically for uniaxial compressive loading. The test specimens are sandwiched between polyetherimide plastic for nondestructive evaluations of the uniply failure mechanisms associated with a range of hole sizes. Finite-element modeling based on classical lamination theory is conducted for the corresponding materials and geometries to reproduce the experimental results analytically. The type of compressive failure is found to be a function of hole size, with fiber buckling/kinking at the hole being the dominant failure mechanism for hole diam/plate width ratios exceeding 0.062. The results of the finite-element analysis supported the experimental data for these failure mechanisms and for those corresponding to smaller hole sizes.

  15. Investigating incidents of EHR failures in China: analysis of search engine reports.

    PubMed

    Lei, Jianbo; Guan, Pengcheng; Gao, Kaihua; Lu, Xueqing; Sittig, Dean

    2013-01-01

    As the healthcare industry becomes increasingly dependent on information technology (IT), the failure of computerized systems could cause catastrophic effects on patient safety. We conducted an empirical study to analyze news articles available on the internet using Baidu and Google. 116 distinct EHR outage news reports were identified. We examined characteristics, potential causes, and possible preventive strategies. Risk management strategies based are discussed.

  16. Large Deformation Dynamic Bending of Composite Beams

    NASA Technical Reports Server (NTRS)

    Derian, E. J.; Hyer, M. W.

    1986-01-01

    Studies were conducted on the large deformation response of composite beams subjected to a dynamic axial load. The beams were loaded with a moderate eccentricity to promote bending. The study was primarily experimental but some finite element results were obtained. Both the deformation and the failure of the beams were of interest. The static response of the beams was also studied to determine potential differences between the static and dynamic failure. Twelve different laminate types were tested. The beams were loaded dynamically with a gravity driven impactor traveling at 19.6 ft/sec and quasi-static tests were conducted on identical beams in a displacement controlled manner. For laminates of practical interest, the failure modes under static and dynamic loadings were identical. Failure in most of the laminate types occurred in a single event involving 40% to 50% of the plies. However, failure in laminates with 30 deg or 15 deg off-axis plies occured in several events. All laminates exhibited bimodular elastic properties. Using empirically determined flexural properties, a finite element analysis was reasonably accurate in predicting the static and dynamic deformation response.

  17. Failure modes of single and multi-bolted joint in the pultruded fiber reinforced polymer composite members

    NASA Astrophysics Data System (ADS)

    Kim, S. Y.; Yoo, J. H.; Kim, H. K.; Shin, K. Y.; Yoon, S. J.

    2018-06-01

    In this paper, we discussed the structural behavior of bolted lap-joint connections in pultruded FRP structural members. Especially, bolted connections in pultruded FRP members are investigated for their failure modes and strength. Specimens with single and multiple bolt-holes are tested in tension under bolt-loading conditions. All of the specimens are instrumented with strain gages and the load-strain responses are monitored. The failed specimens are examined for the cracks and failure patterns. The purpose of this paper is to predict the failure strength by using the ratio of the results obtained by the experiment and the finite element analysis. In the study, several tests are conducted to determine the mechanical properties of pultruded FRP materials before the main experiment. The results are used in the finite element analysis for single and multiple bolted lap-joint specimens. The results obtained by the experiment are compared with the results obtained by the finite element analysis.

  18. A Numerical Round Robin for the Reliability Prediction of Structural Ceramics

    NASA Technical Reports Server (NTRS)

    Powers, Lynn M.; Janosik, Lesley A.

    1993-01-01

    A round robin has been conducted on integrated fast fracture design programs for brittle materials. An informal working group (WELFEP-WEakest Link failure probability prediction by Finite Element Postprocessors) was formed to discuss and evaluate the implementation of the programs examined in the study. Results from the study have provided insight on the differences between the various programs examined. Conclusions from the study have shown that when brittle materials are used in design, analysis must understand how to apply the concepts presented herein to failure probability analysis.

  19. Risk analysis of gravity dam instability using credibility theory Monte Carlo simulation model.

    PubMed

    Xin, Cao; Chongshi, Gu

    2016-01-01

    Risk analysis of gravity dam stability involves complicated uncertainty in many design parameters and measured data. Stability failure risk ratio described jointly by probability and possibility has deficiency in characterization of influence of fuzzy factors and representation of the likelihood of risk occurrence in practical engineering. In this article, credibility theory is applied into stability failure risk analysis of gravity dam. Stability of gravity dam is viewed as a hybrid event considering both fuzziness and randomness of failure criterion, design parameters and measured data. Credibility distribution function is conducted as a novel way to represent uncertainty of influence factors of gravity dam stability. And combining with Monte Carlo simulation, corresponding calculation method and procedure are proposed. Based on a dam section, a detailed application of the modeling approach on risk calculation of both dam foundation and double sliding surfaces is provided. The results show that, the present method is feasible to be applied on analysis of stability failure risk for gravity dams. The risk assessment obtained can reflect influence of both sorts of uncertainty, and is suitable as an index value.

  20. Analysis of Emergency Diesel Generators Failure Incidents in Nuclear Power Plants

    NASA Astrophysics Data System (ADS)

    Hunt, Ronderio LaDavis

    In early years of operation, emergency diesel generators have had a minimal rate of demand failures. Emergency diesel generators are designed to operate as a backup when the main source of electricity has been disrupted. As of late, EDGs (emergency diesel generators) have been failing at NPPs (nuclear power plants) around the United States causing either station blackouts or loss of onsite and offsite power. These failures occurred from a specific type called demand failures. This thesis evaluated the current problem that raised concern in the nuclear industry which was averaging 1 EDG demand failure/year in 1997 to having an excessive event of 4 EDG demand failure year which occurred in 2011. To determine the next occurrence of the extreme event and possible cause to an event of such happening, two analyses were conducted, the statistical and root cause analysis. Considering the statistical analysis in which an extreme event probability approach was applied to determine the next occurrence year of an excessive event as well as, the probability of that excessive event occurring. Using the root cause analysis in which the potential causes of the excessive event occurred by evaluating, the EDG manufacturers, aging, policy changes/ maintenance practices and failure components. The root cause analysis investigated the correlation between demand failure data and historical data. Final results from the statistical analysis showed expectations of an excessive event occurring in a fixed range of probability and a wider range of probability from the extreme event probability approach. The root-cause analysis of the demand failure data followed historical statistics for the EDG manufacturer, aging and policy changes/ maintenance practices but, indicated a possible cause regarding the excessive event with the failure components. Conclusions showed the next excessive demand failure year, prediction of the probability and the next occurrence year of such failures, with an acceptable confidence level, was difficult but, it was likely that this type of failure will not be a 100 year event. It was noticeable to see that the majority of the EDG demand failures occurred within the main components as of 2005. The overall analysis of this study provided from percentages, indicated that it would be appropriate to make the statement that the excessive event was caused by the overall age (wear and tear) of the Emergency Diesel Generators in Nuclear Power Plants. Future Work will be to better determine the return period of the excessive event once the occurrence has happened for a second time by implementing the extreme event probability approach.

  1. Photovoltaic module reliability improvement through application testing and failure analysis

    NASA Technical Reports Server (NTRS)

    Dumas, L. N.; Shumka, A.

    1982-01-01

    During the first four years of the U.S. Department of Energy (DOE) National Photovoltatic Program, the Jet Propulsion Laboratory Low-Cost Solar Array (LSA) Project purchased about 400 kW of photovoltaic modules for test and experiments. In order to identify, report, and analyze test and operational problems with the Block Procurement modules, a problem/failure reporting and analysis system was implemented by the LSA Project with the main purpose of providing manufacturers with feedback from test and field experience needed for the improvement of product performance and reliability. A description of the more significant types of failures is presented, taking into account interconnects, cracked cells, dielectric breakdown, delamination, and corrosion. Current design practices and reliability evaluations are also discussed. The conducted evaluation indicates that current module designs incorporate damage-resistant and fault-tolerant features which address field failure mechanisms observed to date.

  2. [Failure modes and effects analysis in the prescription, validation and dispensing process].

    PubMed

    Delgado Silveira, E; Alvarez Díaz, A; Pérez Menéndez-Conde, C; Serna Pérez, J; Rodríguez Sagrado, M A; Bermejo Vicedo, T

    2012-01-01

    To apply a failure modes and effects analysis to the prescription, validation and dispensing process for hospitalised patients. A work group analysed all of the stages included in the process from prescription to dispensing, identifying the most critical errors and establishing potential failure modes which could produce a mistake. The possible causes, their potential effects, and the existing control systems were analysed to try and stop them from developing. The Hazard Score was calculated, choosing those that were ≥ 8, and a Severity Index = 4 was selected independently of the hazard Score value. Corrective measures and an implementation plan were proposed. A flow diagram that describes the whole process was obtained. A risk analysis was conducted of the chosen critical points, indicating: failure mode, cause, effect, severity, probability, Hazard Score, suggested preventative measure and strategy to achieve so. Failure modes chosen: Prescription on the nurse's form; progress or treatment order (paper); Prescription to incorrect patient; Transcription error by nursing staff and pharmacist; Error preparing the trolley. By applying a failure modes and effects analysis to the prescription, validation and dispensing process, we have been able to identify critical aspects, the stages in which errors may occur and the causes. It has allowed us to analyse the effects on the safety of the process, and establish measures to prevent or reduce them. Copyright © 2010 SEFH. Published by Elsevier Espana. All rights reserved.

  3. Impact Testing of Aluminum 2024 and Titanium 6Al-4V for Material Model Development

    NASA Technical Reports Server (NTRS)

    Pereira, J. Michael; Revilock, Duane M.; Lerch, Bradley A.; Ruggeri, Charles R.

    2013-01-01

    One of the difficulties with developing and verifying accurate impact models is that parameters such as high strain rate material properties, failure modes, static properties, and impact test measurements are often obtained from a variety of different sources using different materials, with little control over consistency among the different sources. In addition there is often a lack of quantitative measurements in impact tests to which the models can be compared. To alleviate some of these problems, a project is underway to develop a consistent set of material property, impact test data and failure analysis for a variety of aircraft materials that can be used to develop improved impact failure and deformation models. This project is jointly funded by the NASA Glenn Research Center and the FAA William J. Hughes Technical Center. Unique features of this set of data are that all material property data and impact test data are obtained using identical material, the test methods and procedures are extensively documented and all of the raw data is available. Four parallel efforts are currently underway: Measurement of material deformation and failure response over a wide range of strain rates and temperatures and failure analysis of material property specimens and impact test articles conducted by The Ohio State University; development of improved numerical modeling techniques for deformation and failure conducted by The George Washington University; impact testing of flat panels and substructures conducted by NASA Glenn Research Center. This report describes impact testing which has been done on aluminum (Al) 2024 and titanium (Ti) 6Al-4vanadium (V) sheet and plate samples of different thicknesses and with different types of projectiles, one a regular cylinder and one with a more complex geometry incorporating features representative of a jet engine fan blade. Data from this testing will be used in validating material models developed under this program. The material tests and the material models developed in this program will be published in separate reports.

  4. Failure Criterion For Isotropic Time Dependent Materials Which Accounts for Multi-Axial Loading

    NASA Technical Reports Server (NTRS)

    Richardson, D. E.; Anderson, G. L.; Macon, D. J.

    2003-01-01

    The Space Shuttle's Reusable Solid Rocket Motor (RSRM) nozzle program has recently conducted testing to characterize the effects of multi-axial loading, temperature and time on the failure characteristics of TIGA321, EA913NA, EA946 (three filled epoxy adhesives). From the test data a "Multi-Axial, Temperature, and Time Dependent" or MATT failure criterion was developed. It is shown that this criterion simplifies, for constant load and constant load rate conditions, into a form that can be easily used for stress analysis. Failure for TIGA321 and EA913NA are characterized below their glass transition temperature. Failure for EA946 is characterized for conditions that pass through its glass transition. The MATT failure criterion is shown to be accurate for a wide range of conditions for these adhesives.

  5. Round-robin analysis of the behavior of a 1:6-scale reinforced concrete containment model pressurized to failure: Posttest evaluations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Clauss, D.B.

    A 1:6-scale model of a reinforced concrete containment building was pressurized incrementally to failure at a remote site at Sandia National Laboratories. The response of the model was recorded with more than 1000 channels of data (primarily strain and displacement measurements) at 37 discrete pressure levels. The primary objective of this test was to generate data that could be used to validate methods for predicting the performance of containment buildings subject to loads beyond their design basis. Extensive analyses were conducted before the test to predict the behavior of the model. Ten organizations in Europe and the US conducted independentmore » analyses of the model and contributed to a report on the pretest predictions. Predictions included structural response at certain predetermined locations in the model as well as capacity and failure mode. This report discusses comparisons between the pretest predictions and the experimental results. Posttest evaluations that were conducted to provide additional insight into the model behavior are also described. The significance of the analysis and testing of the 1:6-scale model to performance evaluations of actual containments subject to beyond design basis loads is also discussed. 70 refs., 428 figs., 24 tabs.« less

  6. Analysis and test of low profile aluminum aerospace tank dome

    NASA Astrophysics Data System (ADS)

    Ahmed, R.; Wilhelm, J. M.

    1993-12-01

    In order to increase the structural performance of cryogenic tanks, the aerospace industry is beginning to employ low-profile bulkheads in new generation launch vehicle designs. This report details the analysis and test of one such dome made from 2219 aluminum. Such domes have two potential failure modes under internal pressure, general tensile failure and hoop compression buckling (in regions near the equator). The test determined the buckling load and ultimate tensile load of the hardware and showed that both compared well with the analysis predictions. This effort was conducted under the auspices of NASA and the General Dynamics Cryogenic Tank Technology Program (CTTP).

  7. Analysis and test of low profile aluminum aerospace tank dome

    NASA Technical Reports Server (NTRS)

    Ahmed, R.; Wilhelm, J. M.

    1993-01-01

    In order to increase the structural performance of cryogenic tanks, the aerospace industry is beginning to employ low-profile bulkheads in new generation launch vehicle designs. This report details the analysis and test of one such dome made from 2219 aluminum. Such domes have two potential failure modes under internal pressure, general tensile failure and hoop compression buckling (in regions near the equator). The test determined the buckling load and ultimate tensile load of the hardware and showed that both compared well with the analysis predictions. This effort was conducted under the auspices of NASA and the General Dynamics Cryogenic Tank Technology Program (CTTP).

  8. The Shuttle processing contractors (SPC) reliability program at the Kennedy Space Center - The real world

    NASA Astrophysics Data System (ADS)

    McCrea, Terry

    The Shuttle Processing Contract (SPC) workforce consists of Lockheed Space Operations Co. as prime contractor, with Grumman, Thiokol Corporation, and Johnson Controls World Services as subcontractors. During the design phase, reliability engineering is instrumental in influencing the development of systems that meet the Shuttle fail-safe program requirements. Reliability engineers accomplish this objective by performing FMEA (failure modes and effects analysis) to identify potential single failure points. When technology, time, or resources do not permit a redesign to eliminate a single failure point, the single failure point information is formatted into a change request and presented to senior management of SPC and NASA for risk acceptance. In parallel with the FMEA, safety engineering conducts a hazard analysis to assure that potential hazards to personnel are assessed. The combined effort (FMEA and hazard analysis) is published as a system assurance analysis. Special ground rules and techniques are developed to perform and present the analysis. The reliability program at KSC is vigorously pursued, and has been extremely successful. The ground support equipment and facilities used to launch and land the Space Shuttle maintain an excellent reliability record.

  9. Defective support network: a major obstacle to coping for patients with heart failure: a qualitative study

    PubMed Central

    Shahrbabaki, Parvin Mangolian; Nouhi, Esmat; Kazemi, Majid; Ahmadi, Fazlollah

    2016-01-01

    Background Heart failure as a chronic disease poses many challenges for a patient in his or her everyday life. Support in various aspects of life positively affects coping strategies and influences the well-being and health outcomes of heart failure patients. Inadequate support may lead to a worsening of symptoms, increased hospital readmissions, psychological disorders, and a reduced quality of life. Objective This study explored obstacles to coping related to support for heart failure patients as viewed by the patients themselves and their family members and caregivers. Design This qualitative study was conducted using content analysis. The 20 Iranian participants included 11 patients with heart failure, three cardiologists, three nurses, and three family members of heart failure patients selected through purposive sampling. Data were collected through semi-structured interviews and analyzed using the Lundman and Graneheim qualitative content analysis method. Results During data analysis, ‘defective support network’ developed as the main theme along with four other categories of ‘inadequate family performance’, ‘inadequate support by the healthcare team’, ‘distorted societal social support’, and ‘inadequate welfare support’. Conclusion The findings of the current study can assist health authorities and planners in identifying the needs of patients with heart failure so as to focus and plan on facilitating their coping as much as possible by obviating the existing obstacles. PMID:27041539

  10. A streamlined failure mode and effects analysis.

    PubMed

    Ford, Eric C; Smith, Koren; Terezakis, Stephanie; Croog, Victoria; Gollamudi, Smitha; Gage, Irene; Keck, Jordie; DeWeese, Theodore; Sibley, Greg

    2014-06-01

    Explore the feasibility and impact of a streamlined failure mode and effects analysis (FMEA) using a structured process that is designed to minimize staff effort. FMEA for the external beam process was conducted at an affiliate radiation oncology center that treats approximately 60 patients per day. A structured FMEA process was developed which included clearly defined roles and goals for each phase. A core group of seven people was identified and a facilitator was chosen to lead the effort. Failure modes were identified and scored according to the FMEA formalism. A risk priority number,RPN, was calculated and used to rank failure modes. Failure modes with RPN > 150 received safety improvement interventions. Staff effort was carefully tracked throughout the project. Fifty-two failure modes were identified, 22 collected during meetings, and 30 from take-home worksheets. The four top-ranked failure modes were: delay in film check, missing pacemaker protocol/consent, critical structures not contoured, and pregnant patient simulated without the team's knowledge of the pregnancy. These four failure modes had RPN > 150 and received safety interventions. The FMEA was completed in one month in four 1-h meetings. A total of 55 staff hours were required and, additionally, 20 h by the facilitator. Streamlined FMEA provides a means of accomplishing a relatively large-scale analysis with modest effort. One potential value of FMEA is that it potentially provides a means of measuring the impact of quality improvement efforts through a reduction in risk scores. Future study of this possibility is needed.

  11. Using Controlled Landslide Initiation Experiments to Test Limit-Equilibrium Analyses of Slope Stability

    NASA Astrophysics Data System (ADS)

    Reid, M. E.; Iverson, R. M.; Brien, D. L.; Iverson, N. R.; Lahusen, R. G.; Logan, M.

    2004-12-01

    Most studies of landslide initiation employ limit equilibrium analyses of slope stability. Owing to a lack of detailed data, however, few studies have tested limit-equilibrium predictions against physical measurements of slope failure. We have conducted a series of field-scale, highly controlled landslide initiation experiments at the USGS debris-flow flume in Oregon; these experiments provide exceptional data to test limit equilibrium methods. In each of seven experiments, we attempted to induce failure in a 0.65m thick, 2m wide, 6m3 prism of loamy sand placed behind a retaining wall in the 31° sloping flume. We systematically investigated triggering of sliding by groundwater injection, by prolonged moderate-intensity sprinkling, and by bursts of high intensity sprinkling. We also used vibratory compaction to control soil porosity and thereby investigate differences in failure behavior of dense and loose soils. About 50 sensors were monitored at 20 Hz during the experiments, including nests of tiltmeters buried at 7 cm spacing to define subsurface failure geometry, and nests of tensiometers and pore-pressure sensors to define evolving pore-pressure fields. In addition, we performed ancillary laboratory tests to measure soil porosity, shear strength, hydraulic conductivity, and compressibility. In loose soils (porosity of 0.52 to 0.55), abrupt failure typically occurred along the flume bed after substantial soil deformation. In denser soils (porosity of 0.41 to 0.44), gradual failure occurred within the soil prism. All failure surfaces had a maximum length to depth ratio of about 7. In even denser soil (porosity of 0.39), we could not induce failure by sprinkling. The internal friction angle of the soils varied from 28° to 40° with decreasing porosity. We analyzed stability at failure, given the observed pore-pressure conditions just prior to large movement, using a 1-D infinite-slope method and a more complete 2-D Janbu method. Each method provides a static Factor of Safety (FS), and in theory failure occurs when FS ≤ 1. Using the 1-D analysis, all experiments having failure had FS well below 1 (typically 0.5-0.8). Using the 2-D analysis for these same conditions, FS was less than but closer to 1 (typically 0.8-0.9). For the experiment with no failure, the 2-D FS was, reassuringly, > 1. These results indicate that the 2-D Janbu analysis is more accurate than the 1-D infinite-slope method for computing limit-equilibrium slope stability in shallow slides with limited areal extent.

  12. 16 CFR 1211.5 - General testing parameters.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... condition flow chart shown in figure 1 shall be used: (1) To conduct a failure-mode and effect analysis (FMEA); (2) In investigating the performance during the Environmental Stress Tests; and (3) During the...

  13. Adaptive servo ventilation for central sleep apnoea in heart failure: SERVE-HF on-treatment analysis.

    PubMed

    Woehrle, Holger; Cowie, Martin R; Eulenburg, Christine; Suling, Anna; Angermann, Christiane; d'Ortho, Marie-Pia; Erdmann, Erland; Levy, Patrick; Simonds, Anita K; Somers, Virend K; Zannad, Faiez; Teschler, Helmut; Wegscheider, Karl

    2017-08-01

    This on-treatment analysis was conducted to facilitate understanding of mechanisms underlying the increased risk of all-cause and cardiovascular mortality in heart failure patients with reduced ejection fraction and predominant central sleep apnoea randomised to adaptive servo ventilation versus the control group in the SERVE-HF trial.Time-dependent on-treatment analyses were conducted (unadjusted and adjusted for predictive covariates). A comprehensive, time-dependent model was developed to correct for asymmetric selection effects (to minimise bias).The comprehensive model showed increased cardiovascular death hazard ratios during adaptive servo ventilation usage periods, slightly lower than those in the SERVE-HF intention-to-treat analysis. Self-selection bias was evident. Patients randomised to adaptive servo ventilation who crossed over to the control group were at higher risk of cardiovascular death than controls, while control patients with crossover to adaptive servo ventilation showed a trend towards lower risk of cardiovascular death than patients randomised to adaptive servo ventilation. Cardiovascular risk did not increase as nightly adaptive servo ventilation usage increased.On-treatment analysis showed similar results to the SERVE-HF intention-to-treat analysis, with an increased risk of cardiovascular death in heart failure with reduced ejection fraction patients with predominant central sleep apnoea treated with adaptive servo ventilation. Bias is inevitable and needs to be taken into account in any kind of on-treatment analysis in positive airway pressure studies. Copyright ©ERS 2017.

  14. The VHCF experimental investigation of FV520B-I with surface roughness Ry

    NASA Astrophysics Data System (ADS)

    Wang, J. L.; Zhang, Y. L.; Ding, M. C.; Zhao, Q. C.

    2018-05-01

    Different surface roughness type (Ra and Ry) has different effect on the VHCF failure and life. Ra is widely employed as the quantitative expression of the surface roughness, but there are few fatigue failure mechanism analysis and experimental study under surface roughness Ry. The VHCF experiment is conducted out using the specimen with different surface roughness values. The surface roughness Ry is employed as the major research object to investigate the relationship and distribution tendency between the Ry, fatigue life and the distance between internal inclusion and surface, and a new VHCF failure character is proposed.

  15. Cycle life test and failure model of nickel-hydrogen cells

    NASA Technical Reports Server (NTRS)

    Smithrick, J. J.

    1983-01-01

    Six ampere hour individual pressure vessel nickel hydrogen cells were charge/discharge cycled to failure. Failure as used here is defined to occur when the end of discharge voltage degraded to 0.9 volts. They were cycled under a low earth orbit cycle regime to a deep depth of discharge (80 percent of rated ampere hour capacity). Both cell designs were fabricated by the same manufacturer and represent current state of the art. A failure model was advanced which suggests both cell designs have inadequate volume tolerance characteristics. The limited existing data base at a deep depth of discharge (DOD) was expanded. Two cells of each design were cycled. One COMSAT cell failed at cycle 1712 and the other failed at cycle 1875. For the Air Force/Hughes cells, one cell failed at cycle 2250 and the other failed at cycle 2638. All cells, of both designs, failed due to low end of discharge voltage (0.9 volts). No cell failed due to electrical shorts. After cell failure, three different reconditioning tests (deep discharge, physical reorientation, and open circuit voltage stand) were conducted on all cells of each design. A fourth reconditioning test (electrolyte addition) was conducted on one cell of each design. In addition post cycle cell teardown and failure analysis were performed on the one cell of each design which did not have electrolyte added after failure.

  16. Failure mode and effects analysis outputs: are they valid?

    PubMed

    Shebl, Nada Atef; Franklin, Bryony Dean; Barber, Nick

    2012-06-10

    Failure Mode and Effects Analysis (FMEA) is a prospective risk assessment tool that has been widely used within the aerospace and automotive industries and has been utilised within healthcare since the early 1990s. The aim of this study was to explore the validity of FMEA outputs within a hospital setting in the United Kingdom. Two multidisciplinary teams each conducted an FMEA for the use of vancomycin and gentamicin. Four different validity tests were conducted: Face validity: by comparing the FMEA participants' mapped processes with observational work. Content validity: by presenting the FMEA findings to other healthcare professionals. Criterion validity: by comparing the FMEA findings with data reported on the trust's incident report database. Construct validity: by exploring the relevant mathematical theories involved in calculating the FMEA risk priority number. Face validity was positive as the researcher documented the same processes of care as mapped by the FMEA participants. However, other healthcare professionals identified potential failures missed by the FMEA teams. Furthermore, the FMEA groups failed to include failures related to omitted doses; yet these were the failures most commonly reported in the trust's incident database. Calculating the RPN by multiplying severity, probability and detectability scores was deemed invalid because it is based on calculations that breach the mathematical properties of the scales used. There are significant methodological challenges in validating FMEA. It is a useful tool to aid multidisciplinary groups in mapping and understanding a process of care; however, the results of our study cast doubt on its validity. FMEA teams are likely to need different sources of information, besides their personal experience and knowledge, to identify potential failures. As for FMEA's methodology for scoring failures, there were discrepancies between the teams' estimates and similar incidents reported on the trust's incident database. Furthermore, the concept of multiplying ordinal scales to prioritise failures is mathematically flawed. Until FMEA's validity is further explored, healthcare organisations should not solely depend on their FMEA results to prioritise patient safety issues.

  17. Microcracking, microcrack-induced delamination, and longitudinal splitting of advanced composite structures

    NASA Technical Reports Server (NTRS)

    Nairn, John A.

    1992-01-01

    A combined analytical and experimental study was conducted to analyze microcracking, microcrack-induced delamination, and longitudinal splitting in polymer matrix composites. Strain energy release rates, calculated by a variational analysis, were used in a failure criterion to predict microcracking. Predictions and test results were compared for static, fatigue, and cyclic thermal loading. The longitudinal splitting analysis accounted for the effects of fiber bridging. Test data are analyzed and compared for longitudinal splitting and delamination under mixed-mode loading. This study emphasizes the importance of using fracture mechanics analyses to understand the complex failure processes that govern composite strength and life.

  18. Testing Hypothesized Psychosocial Mediators: Lessons Learned in the MassBUILT Study

    ERIC Educational Resources Information Center

    Okechukwu, Cassandra A.; Krieger, Nancy; Sorensen, Glorian; Li, Yi; Barbeau, Elizabeth M.

    2011-01-01

    Only a few of the interventions that target blue-collar workers have conducted formal analysis to evaluate the specific attributes of their intervention that are associated with success or failure. This study examined the role of dual hazard and decisional balance in the MassBUILT smoking cessation intervention. The authors conducted sets of…

  19. Reliability-based management of buried pipelines considering external corrosion defects

    NASA Astrophysics Data System (ADS)

    Miran, Seyedeh Azadeh

    Corrosion is one of the main deteriorating mechanisms that degrade the energy pipeline integrity, due to transferring corrosive fluid or gas and interacting with corrosive environment. Corrosion defects are usually detected by periodical inspections using in-line inspection (ILI) methods. In order to ensure pipeline safety, this study develops a cost-effective maintenance strategy that consists of three aspects: corrosion growth model development using ILI data, time-dependent performance evaluation, and optimal inspection interval determination. In particular, the proposed study is applied to a cathodic protected buried steel pipeline located in Mexico. First, time-dependent power-law formulation is adopted to probabilistically characterize growth of the maximum depth and length of the external corrosion defects. Dependency between defect depth and length are considered in the model development and generation of the corrosion defects over time is characterized by the homogenous Poisson process. The growth models unknown parameters are evaluated based on the ILI data through the Bayesian updating method with Markov Chain Monte Carlo (MCMC) simulation technique. The proposed corrosion growth models can be used when either matched or non-matched defects are available, and have ability to consider newly generated defects since last inspection. Results of this part of study show that both depth and length growth models can predict damage quantities reasonably well and a strong correlation between defect depth and length is found. Next, time-dependent system failure probabilities are evaluated using developed corrosion growth models considering prevailing uncertainties where three failure modes, namely small leak, large leak and rupture are considered. Performance of the pipeline is evaluated through failure probability per km (or called a sub-system) where each subsystem is considered as a series system of detected and newly generated defects within that sub-system. Sensitivity analysis is also performed to determine to which incorporated parameter(s) in the growth models reliability of the studied pipeline is most sensitive. The reliability analysis results suggest that newly generated defects should be considered in calculating failure probability, especially for prediction of long-term performance of the pipeline and also, impact of the statistical uncertainty in the model parameters is significant that should be considered in the reliability analysis. Finally, with the evaluated time-dependent failure probabilities, a life cycle-cost analysis is conducted to determine optimal inspection interval of studied pipeline. The expected total life-cycle costs consists construction cost and expected costs of inspections, repair, and failure. The repair is conducted when failure probability from any described failure mode exceeds pre-defined probability threshold after each inspection. Moreover, this study also investigates impact of repair threshold values and unit costs of inspection and failure on the expected total life-cycle cost and optimal inspection interval through a parametric study. The analysis suggests that a smaller inspection interval leads to higher inspection costs, but can lower failure cost and also repair cost is less significant compared to inspection and failure costs.

  20. Simple estimation procedures for regression analysis of interval-censored failure time data under the proportional hazards model.

    PubMed

    Sun, Jianguo; Feng, Yanqin; Zhao, Hui

    2015-01-01

    Interval-censored failure time data occur in many fields including epidemiological and medical studies as well as financial and sociological studies, and many authors have investigated their analysis (Sun, The statistical analysis of interval-censored failure time data, 2006; Zhang, Stat Modeling 9:321-343, 2009). In particular, a number of procedures have been developed for regression analysis of interval-censored data arising from the proportional hazards model (Finkelstein, Biometrics 42:845-854, 1986; Huang, Ann Stat 24:540-568, 1996; Pan, Biometrics 56:199-203, 2000). For most of these procedures, however, one drawback is that they involve estimation of both regression parameters and baseline cumulative hazard function. In this paper, we propose two simple estimation approaches that do not need estimation of the baseline cumulative hazard function. The asymptotic properties of the resulting estimates are given, and an extensive simulation study is conducted and indicates that they work well for practical situations.

  1. Preventing blood transfusion failures: FMEA, an effective assessment method.

    PubMed

    Najafpour, Zhila; Hasoumi, Mojtaba; Behzadi, Faranak; Mohamadi, Efat; Jafary, Mohamadreza; Saeedi, Morteza

    2017-06-30

    Failure Mode and Effect Analysis (FMEA) is a method used to assess the risk of failures and harms to patients during the medical process and to identify the associated clinical issues. The aim of this study was to conduct an assessment of blood transfusion process in a teaching general hospital, using FMEA as the method. A structured FMEA was recruited in our study performed in 2014, and corrective actions were implemented and re-evaluated after 6 months. Sixteen 2-h sessions were held to perform FMEA in the blood transfusion process, including five steps: establishing the context, selecting team members, analysis of the processes, hazard analysis, and developing a risk reduction protocol for blood transfusion. Failure modes with the highest risk priority numbers (RPNs) were identified. The overall RPN scores ranged from 5 to 100 among which, four failure modes were associated with RPNs over 75. The data analysis indicated that failures with the highest RPNs were: labelling (RPN: 100), transfusion of blood or the component (RPN: 100), patient identification (RPN: 80) and sampling (RPN: 75). The results demonstrated that mis-transfusion of blood or blood component is the most important error, which can lead to serious morbidity or mortality. Provision of training to the personnel on blood transfusion, knowledge raising on hazards and appropriate preventative measures, as well as developing standard safety guidelines are essential, and must be implemented during all steps of blood and blood component transfusion.

  2. Induction of labor in elderly nulliparous women.

    PubMed

    Hadar, Eran; Hiersch, Liran; Ashwal, Eran; Chen, Rony; Wiznitzer, Arnon; Gabbay-Benziv, Rinat

    2017-09-01

    Maternal age is an important consideration for antenatal care, labor and delivery. We aimed to evaluate the induction of labor (IoL) failure rates among elderly nulliparous women. We conducted a retrospective analysis of all nulliparous women at 34 + 0 to 41 + 6 weeks, undergoing cervical ripening by prostaglandin E2 (PGE2) vaginal insert. Study group included elderly (≥35 years) nulliparous and control group included non-elderly (<35 years) nulliparous women. Primary outcome was IoL failure rate and secondary outcome was cesarean delivery rate. Outcomes were compared between the groups by univariate analysis followed by regression analysis to adjust results to potential confounders. Of 537 women undergoing IoL, 69 (12.8%) were elderly. The univariate analysis demonstrated no difference in IoL failure rate (26.5% versus 34.8%, p = 0.502) between groups. However, elderly nulliparous women had higher rates of cesarean delivery (36.2% versus 21.4%, p = 0.009). This difference was no longer significant after adjustment for maternal body mass index, indication for delivery, birth weight and gestational age at delivery. Among nulliparous women, older maternal age is not associated with higher rates of IoL failure or cesarean deliveries.

  3. Analysis of failed nuclear plant components

    NASA Astrophysics Data System (ADS)

    Diercks, D. R.

    1993-12-01

    Argonne National Laboratory has conducted analyses of failed components from nuclear power- gener-ating stations since 1974. The considerations involved in working with and analyzing radioactive compo-nents are reviewed here, and the decontamination of these components is discussed. Analyses of four failed components from nuclear plants are then described to illustrate the kinds of failures seen in serv-ice. The failures discussed are (1) intergranular stress- corrosion cracking of core spray injection piping in a boiling water reactor, (2) failure of canopy seal welds in adapter tube assemblies in the control rod drive head of a pressurized water reactor, (3) thermal fatigue of a recirculation pump shaft in a boiling water reactor, and (4) failure of pump seal wear rings by nickel leaching in a boiling water reactor.

  4. A streamlined failure mode and effects analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ford, Eric C., E-mail: eford@uw.edu; Smith, Koren; Terezakis, Stephanie

    Purpose: Explore the feasibility and impact of a streamlined failure mode and effects analysis (FMEA) using a structured process that is designed to minimize staff effort. Methods: FMEA for the external beam process was conducted at an affiliate radiation oncology center that treats approximately 60 patients per day. A structured FMEA process was developed which included clearly defined roles and goals for each phase. A core group of seven people was identified and a facilitator was chosen to lead the effort. Failure modes were identified and scored according to the FMEA formalism. A risk priority number,RPN, was calculated and usedmore » to rank failure modes. Failure modes with RPN > 150 received safety improvement interventions. Staff effort was carefully tracked throughout the project. Results: Fifty-two failure modes were identified, 22 collected during meetings, and 30 from take-home worksheets. The four top-ranked failure modes were: delay in film check, missing pacemaker protocol/consent, critical structures not contoured, and pregnant patient simulated without the team's knowledge of the pregnancy. These four failure modes hadRPN > 150 and received safety interventions. The FMEA was completed in one month in four 1-h meetings. A total of 55 staff hours were required and, additionally, 20 h by the facilitator. Conclusions: Streamlined FMEA provides a means of accomplishing a relatively large-scale analysis with modest effort. One potential value of FMEA is that it potentially provides a means of measuring the impact of quality improvement efforts through a reduction in risk scores. Future study of this possibility is needed.« less

  5. Spacecraft and propulsion technician error

    NASA Astrophysics Data System (ADS)

    Schultz, Daniel Clyde

    Commercial aviation and commercial space similarly launch, fly, and land passenger vehicles. Unlike aviation, the U.S. government has not established maintenance policies for commercial space. This study conducted a mixed methods review of 610 U.S. space launches from 1984 through 2011, which included 31 failures. An analysis of the failure causal factors showed that human error accounted for 76% of those failures, which included workmanship error accounting for 29% of the failures. With the imminent future of commercial space travel, the increased potential for the loss of human life demands that changes be made to the standardized procedures, training, and certification to reduce human error and failure rates. Several recommendations were made by this study to the FAA's Office of Commercial Space Transportation, space launch vehicle operators, and maintenance technician schools in an effort to increase the safety of the space transportation passengers.

  6. Physical and chemical analysis of lithium-ion battery cell-to-cell failure events inside custom fire chamber

    NASA Astrophysics Data System (ADS)

    Spinner, Neil S.; Field, Christopher R.; Hammond, Mark H.; Williams, Bradley A.; Myers, Kristina M.; Lubrano, Adam L.; Rose-Pehrsson, Susan L.; Tuttle, Steven G.

    2015-04-01

    A 5-cubic meter decompression chamber was re-purposed as a fire test chamber to conduct failure and abuse experiments on lithium-ion batteries. Various modifications were performed to enable remote control and monitoring of chamber functions, along with collection of data from instrumentation during tests including high speed and infrared cameras, a Fourier transform infrared spectrometer, real-time gas analyzers, and compact reconfigurable input and output devices. Single- and multi-cell packages of LiCoO2 chemistry 18650 lithium-ion batteries were constructed and data was obtained and analyzed for abuse and failure tests. Surrogate 18650 cells were designed and fabricated for multi-cell packages that mimicked the thermal behavior of real cells without using any active components, enabling internal temperature monitoring of cells adjacent to the active cell undergoing failure. Heat propagation and video recordings before, during, and after energetic failure events revealed a high degree of heterogeneity; some batteries exhibited short burst of sparks while others experienced a longer, sustained flame during failure. Carbon monoxide, carbon dioxide, methane, dimethyl carbonate, and ethylene carbonate were detected via gas analysis, and the presence of these species was consistent throughout all failure events. These results highlight the inherent danger in large format lithium-ion battery packs with regards to cell-to-cell failure, and illustrate the need for effective safety features.

  7. Construct validity of the Heart Failure Screening Tool (Heart-FaST) to identify heart failure patients at risk of poor self-care: Rasch analysis.

    PubMed

    Reynolds, Nicholas A; Ski, Chantal F; McEvedy, Samantha M; Thompson, David R; Cameron, Jan

    2018-02-14

    The aim of this study was to psychometrically evaluate the Heart Failure Screening Tool (Heart-FaST) via: (1) examination of internal construct validity; (2) testing of scale function in accordance with design; and (3) recommendation for change/s, if items are not well adjusted, to improve psychometric credential. Self-care is vital to the management of heart failure. The Heart-FaST may provide a prospective assessment of risk, regarding the likelihood that patients with heart failure will engage in self-care. Psychometric validation of the Heart-FaST using Rasch analysis. The Heart-FaST was administered to 135 patients (median age = 68, IQR = 59-78 years; 105 males) enrolled in a multidisciplinary heart failure management program. The Heart-FaST is a nurse-administered tool for screening patients with HF at risk of poor self-care. A Rasch analysis of responses was conducted which tested data against Rasch model expectations, including whether items serve as unbiased, non-redundant indicators of risk and measure a single construct and that rating scales operate as intended. The results showed that data met Rasch model expectations after rescoring or deleting items due to poor discrimination, disordered thresholds, differential item functioning, or response dependence. There was no evidence of multidimensionality which supports the use of total scores from Heart-FaST as indicators of risk. Aggregate scores from this modified screening tool rank heart failure patients according to their "risk of poor self-care" demonstrating that the Heart-FaST items constitute a meaningful scale to identify heart failure patients at risk of poor engagement in heart failure self-care. © 2018 John Wiley & Sons Ltd.

  8. Tools for Economic Analysis of Patient Management Interventions in Heart Failure Cost-Effectiveness Model: A Web-based program designed to evaluate the cost-effectiveness of disease management programs in heart failure.

    PubMed

    Reed, Shelby D; Neilson, Matthew P; Gardner, Matthew; Li, Yanhong; Briggs, Andrew H; Polsky, Daniel E; Graham, Felicia L; Bowers, Margaret T; Paul, Sara C; Granger, Bradi B; Schulman, Kevin A; Whellan, David J; Riegel, Barbara; Levy, Wayne C

    2015-11-01

    Heart failure disease management programs can influence medical resource use and quality-adjusted survival. Because projecting long-term costs and survival is challenging, a consistent and valid approach to extrapolating short-term outcomes would be valuable. We developed the Tools for Economic Analysis of Patient Management Interventions in Heart Failure Cost-Effectiveness Model, a Web-based simulation tool designed to integrate data on demographic, clinical, and laboratory characteristics; use of evidence-based medications; and costs to generate predicted outcomes. Survival projections are based on a modified Seattle Heart Failure Model. Projections of resource use and quality of life are modeled using relationships with time-varying Seattle Heart Failure Model scores. The model can be used to evaluate parallel-group and single-cohort study designs and hypothetical programs. Simulations consist of 10,000 pairs of virtual cohorts used to generate estimates of resource use, costs, survival, and incremental cost-effectiveness ratios from user inputs. The model demonstrated acceptable internal and external validity in replicating resource use, costs, and survival estimates from 3 clinical trials. Simulations to evaluate the cost-effectiveness of heart failure disease management programs across 3 scenarios demonstrate how the model can be used to design a program in which short-term improvements in functioning and use of evidence-based treatments are sufficient to demonstrate good long-term value to the health care system. The Tools for Economic Analysis of Patient Management Interventions in Heart Failure Cost-Effectiveness Model provides researchers and providers with a tool for conducting long-term cost-effectiveness analyses of disease management programs in heart failure. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. When Does Maluma/Takete Fail? Two Key Failures and a Meta-Analysis Suggest That Phonology and Phonotactics Matter.

    PubMed

    Styles, Suzy J; Gawne, Lauren

    2017-01-01

    Eighty-seven years ago, Köhler reported that the majority of students picked the same answer in a quiz: Which novel word form ('maluma' or 'takete') went best with which abstract line drawing (one curved, one angular). Others have consistently shown the effect in a variety of contexts, with only one reported failure by Rogers and Ross. In the spirit of transparency, we report our own failure in the same journal. In our study, speakers of Syuba, from the Himalaya in Nepal, do not show a preference when matching word forms 'kiki' and 'bubu' to spiky versus curvy shapes. We conducted a meta-analysis of previous studies to investigate the relationship between pseudoword legality and task effects. Our combined analyses suggest a common source for both of the failures: 'wordiness' - We believe these tests fail when the test words do not behave according to the sound structure of the target language.

  10. Predictions of structural integrity of steam generator tubes under normal operating, accident, an severe accident conditions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Majumdar, S.

    1997-02-01

    Available models for predicting failure of flawed and unflawed steam generator tubes under normal operating, accident, and severe accident conditions are reviewed. Tests conducted in the past, though limited, tended to show that the earlier flow-stress model for part-through-wall axial cracks overestimated the damaging influence of deep cracks. This observation was confirmed by further tests at high temperatures, as well as by finite-element analysis. A modified correlation for deep cracks can correct this shortcoming of the model. Recent tests have shown that lateral restraint can significantly increase the failure pressure of tubes with unsymmetrical circumferential cracks. This observation was confirmedmore » by finite-element analysis. The rate-independent flow stress models that are successful at low temperatures cannot predict the rate-sensitive failure behavior of steam generator tubes at high temperatures. Therefore, a creep rupture model for predicting failure was developed and validated by tests under various temperature and pressure loadings that can occur during postulated severe accidents.« less

  11. Stability analysis of chalk sea cliffs using UAV photogrammetry

    NASA Astrophysics Data System (ADS)

    Barlow, John; Gilham, Jamie

    2017-04-01

    Cliff erosion and instability poses a significant hazard to communities and infrastructure located is coastal areas. We use point cloud and spectral data derived from close range digital photogrammetry to assess the stability of chalk sea cliffs located at Telscombe, UK. Data captured from an unmanned aerial vehicle (UAV) were used to generate dense point clouds for a 712 m section of cliff face which ranges from 20 to 49 m in height. Generated models fitted our ground control network within a standard error of 0.03 m. Structural features such as joints, bedding planes, and faults were manually mapped and are consistent with results from other studies that have been conducted using direct measurement in the field. Kinematic analysis of these data was used to identify the primary modes of failure at the site. Our results indicate that wedge failure is by far the most likely mode of slope instability. An analysis of sequential surveys taken from the summer of 2016 to the winter of 2017 indicate several large failures have occurred at the site. We establish the volume of failure through change detection between sequential data sets and use back analysis to determine the strength of shear surfaces for each failure. Our results show that data capture through UAV photogrammetry can provide useful information for slope stability analysis over long sections of cliff. The use of this technology offers significant benefits in equipment costs and field time over existing methods.

  12. Aquatic exercise training and stable heart failure: A systematic review and meta-analysis.

    PubMed

    Adsett, Julie A; Mudge, Alison M; Morris, Norman; Kuys, Suzanne; Paratz, Jennifer D

    2015-01-01

    A meta-analysis and review of the evidence was conducted to determine the efficacy of aquatic exercise training for individuals with heart failure compared to traditional land-based programmes. A systematic search was conducted for studies published prior to March 2014, using MEDLINE, PUBMED, Cochrane Library, CINAHL and PEDro databases. Key words and synonyms relating to aquatic exercise and heart failure comprised the search strategy. Interventions included aquatic exercise or a combination of aquatic plus land-based training, whilst comparator protocols included usual care, no exercise or land-based training alone. The primary outcome of interest was exercise performance. Studies reporting on muscle strength, quality of life and a range of haemodynamic and physiological parameters were also reviewed. Eight studies met criteria, accounting for 156 participants. Meta-analysis identified studies including aquatic exercise to be superior to comparator protocols for 6 minute walk test (p < 0.004) and peak power (p < 0.044). Compared to land-based training programmes, aquatic exercise training provided similar benefits for VO(2peak), muscle strength and quality of life, though was not superior. Cardiac dimensions, left ventricular ejection fraction, cardiac output and BNP were not influenced by aquatic exercise training. For those with stable heart failure, aquatic exercise training can improve exercise capacity, muscle strength and quality of life similar to land-based training programmes. This form of exercise may provide a safe and effective alternative for those unable to participate in traditional exercise programmes. Crown Copyright © 2015. Published by Elsevier Ireland Ltd. All rights reserved.

  13. ATM CMG bearing failure analysis

    NASA Technical Reports Server (NTRS)

    1975-01-01

    The cause or causes for the failure of ATM CMG S/N 5 (Skylab 1) and the anomalies associated with ATM CMG S/N 6 (Skylab 2) were investigated. Skylab telemetry data were reviewed and presented in the form of parameter distributions. The theory that the problems were caused by marginal bearing lubrication was studied along with the effects of orbital conditions on lubricants. Bearing tests were performed to investigate the effect of lubricant or lack of lubricant in the ATM CMG bearings and the dispersion and migration of the lubricant. The vacuum and weightless conditions of space were simulated in the bearing tests. Analysis of the results of the tests conducted points to inadequate lubrication as the predominant factor causing the failure of ATM CMG S/N 5 (Skylab 1) and the anomalies associated with ATM CMG S/N 6 (Skylab 2).

  14. Analysis and Test Correlation of Proof of Concept Box for Blended Wing Body-Low Speed Vehicle

    NASA Technical Reports Server (NTRS)

    Spellman, Regina L.

    2003-01-01

    The Low Speed Vehicle (LSV) is a 14.2% scale remotely piloted vehicle of the revolutionary Blended Wing Body concept. The design of the LSV includes an all composite airframe. Due to internal manufacturing capability restrictions, room temperature layups were necessary. An extensive materials testing and manufacturing process development effort was underwent to establish a process that would achieve the high modulus/low weight properties required to meet the design requirements. The analysis process involved a loads development effort that incorporated aero loads to determine internal forces that could be applied to a traditional FEM of the vehicle and to conduct detailed component analyses. A new tool, Hypersizer, was added to the design process to address various composite failure modes and to optimize the skin panel thickness of the upper and lower skins for the vehicle. The analysis required an iterative approach as material properties were continually changing. As a part of the material characterization effort, test articles, including a proof of concept wing box and a full-scale wing, were fabricated. The proof of concept box was fabricated based on very preliminary material studies and tested in bending, torsion, and shear. The box was then tested to failure under shear. The proof of concept box was also analyzed using Nastran and Hypersizer. The results of both analyses were scaled to determine the predicted failure load. The test results were compared to both the Nastran and Hypersizer analytical predictions. The actual failure occurred at 899 lbs. The failure was predicted at 1167 lbs based on the Nastran analysis. The Hypersizer analysis predicted a lower failure load of 960 lbs. The Nastran analysis alone was not sufficient to predict the failure load because it does not identify local composite failure modes. This analysis has traditionally been done using closed form solutions. Although Hypersizer is typically used as an optimizer for the design process, the failure prediction was used to help gain acceptance and confidence in this new tool. The correlated models and process were to be used to analyze the full BWB-LSV airframe design. The analysis and correlation with test results of the proof of concept box is presented here, including the comparison of the Nastran and Hypersizer results.

  15. Individual patient data meta-analysis of organ failure in acute pancreatitis: protocol of the PANCREA II study.

    PubMed

    Das, Stephanie L M; Papachristou, George I; De Campos, Tercio; Panek, Jozefa; Poves Prim, Ignasi; Serrablo, Alejandro; Parks, Rowan W; Uomo, Generoso; Windsor, John A; Petrov, Maxim S

    2013-09-10

    Organ failure is a major determinant of mortality in patients with acute pancreatitis. These patients usually require admission to high dependency or intensive care units and consume considerable health care resources. Given a low incidence rate of organ failure and a lack of large non-interventional studies in the field of acute pancreatitis, the characteristics of organ failure that influence outcomes of patients with acute pancreatitis remain largely unknown. Therefore, the Pancreatitis Across Nations Clinical Research and Education Alliance (PANCREA) aims to conduct a meta-analysis of individual patient data from prospective non-interventional studies to determine the influence of timing, duration, sequence, and combination of different organ failures on mortality in patients with acute pancreatitis. Pancreatologists currently active with acute pancreatitis clinical research will be invited to contribute. To be eligible for inclusion patients will have to meet the criteria of acute pancreatitis, develop at least one organ failure during the first week of hospitalization, and not be enrolled into an intervention study. Raw data will then be collated and checked. Individual patient data analysis based on a logistic regression model with adjustment for confounding variables will be done. For all analyses, corresponding 95% confidence intervals and P values will be reported. This collaborative individual patient data meta-analysis will answer important clinical questions regarding patients with acute pancreatitis that develop organ failure. Information derived from this study will be used to optimize routine clinical management and improve care strategies. It can also help validate outcome definitions, allow comparability of results and form a more accurate basis for patient allocation in further clinical studies.

  16. Large Deformation Dynamic Bending of Composite Beams

    NASA Technical Reports Server (NTRS)

    Derian, E. J.; Hyer, M. W.

    1986-01-01

    Studies were conducted on the large deformation response of composite beams subjected to a dynamic axial load. The beams were loaded with a moderate eccentricity to promote bending. The study was primarily experimental but some finite element results were obtained. Both the deformation and the failure of the beams were of interest. The static response of the beams was also studied to determine potential differences between the static and dynamic failure. Twelve different laminate types were tested. The beams tested were 23 in. by 2 in. and generally 30 plies thick. The beams were loaded dynamically with a gravity-driven impactor traveling at 19.6 ft/sec and quasi-static tests were conducted on identical beams in a displacement controlled manner. For laminates of practical interest, the failure modes under static and dynamic loadings were identical. Failure in most of the laminate types occurred in a single event involving 40% to 50% of the plies. However, failure in laminates with 300 or 150 off-axis plies occurred in several events. All laminates exhibited bimodular elastic properties. The compressive flexural moduli in some laminates was measured to be 1/2 the tensile flexural modulus. No simple relationship could be found among the measured ultimate failure strains of the different laminate types. Using empirically determined flexural properties, a finite element analysis was reasonably accurate in predicting the static and dynamic deformation response.

  17. Model 0A wind turbine generator FMEA

    NASA Technical Reports Server (NTRS)

    Klein, William E.; Lalli, Vincent R.

    1989-01-01

    The results of Failure Modes and Effects Analysis (FMEA) conducted for the Wind Turbine Generators are presented. The FMEA was performed for the functional modes of each system, subsystem, or component. The single-point failures were eliminated for most of the systems. The blade system was the only exception. The qualitative probability of a blade separating was estimated at level D-remote. Many changes were made to the hardware as a result of this analysis. The most significant change was the addition of the safety system. Operational experience and need to improve machine availability have resulted in subsequent changes to the various systems which are also reflected in this FMEA.

  18. The durability of endoscopic third ventriculostomy and ventriculoperitoneal shunts in children with hydrocephalus following posterior fossa tumor resection: a systematic review and time-to-failure analysis.

    PubMed

    Dewan, Michael C; Lim, Jaims; Shannon, Chevis N; Wellons, John C

    2017-05-01

    OBJECTIVE Up to one-third of patients with a posterior fossa brain tumor (PFBT) will experience persistent hydrocephalus mandating permanent CSF diversion. The optimal hydrocephalus treatment modality is unknown; the authors sought to compare the durability between endoscopic third ventriculostomy (ETV) and ventriculoperitoneal shunt (VPS) therapy in the pediatric population. METHODS The authors conducted a systematic review of articles indexed in PubMed between 1986 and 2016 describing ETV and/or VPS treatment success/failure and time-to-failure rate in patients < 19 years of age with hydrocephalus related to a PFBT. Additionally, the authors conducted a retrospective review of their institutional series of PFBT patients requiring CSF diversion. Patient data from the systematic review and from the institutional series were aggregated and a time-to-failure analysis was performed comparing ETV and VPS using the Kaplan-Meier method. RESULTS A total of 408 patients were included from 12 studies and the authors' institutional series: 284 who underwent ETV and 124 who underwent VPS placement. The analysis included uncontrolled studies with variable method and timing of CSF diversion and were subject to surgeon bias. No significant differences between cohorts were observed with regard to age, sex, tumor grade or histology, metastatic status, or extent of resection. The cumulative failure rate of ETV was 21%, whereas that of VPS surgery was 29% (p = 0.105). The median time to failure was earlier for ETV than for VPS surgery (0.82 [IQR 0.2-1.8] vs 4.7 months [IQR 0.3-5.7], p = 0.03). Initially the ETV survival curve dropped sharply and then stabilized around 2 months. The VPS curve fell gradually but eventually crossed below the ETV curve at 5.7 months. Overall, a significant survival advantage was not demonstrated for one procedure over the other (p = 0.21, log-rank). However, postoperative complications were higher following VPS (31%) than ETV (17%) (p = 0.012). CONCLUSIONS ETV failure occurred sooner than VPS failure, but long-term treatment durability may be higher for ETV. Complications occurred more commonly with VPS than with ETV. Limited clinical conclusions are drawn using this methodology; the optimal treatment for PFBT-related hydrocephalus warrants investigation through prospective studies.

  19. Risk analysis of autonomous vehicles in mixed traffic streams.

    DOT National Transportation Integrated Search

    2017-05-01

    The objective of this study was to identify the risks associated with the failure of autonomous vehicles in mixed traffic streams and develop strategies to minimize these risks. Three distinct and interconnected phases were used to conduct the risk a...

  20. Cultural factors influencing dietary and fluid restriction behaviour: perceptions of older Chinese patients with heart failure.

    PubMed

    Rong, Xiaoshan; Peng, Youqing; Yu, Hai-Ping; Li, Dan

    2017-03-01

    To explore the cultural factors related to dietary and fluid restriction behaviours among older Chinese patients. Excess dietary sodium and fluid intake are risk factors contributing to the worsening and rehospitalisation for heart failure in older patients. Managing the complex fluid and diet requirements of heart failure patients is challenging and is made more complicated by cultural variations in self-management behaviours in response to a health threat. Qualitative study using semi-structured in interviews and framework analysis. The design of this study is qualitative descriptive. Semi-structured in-depth interviews were conducted with 15 heart failure patients. Data were analysed through content analysis. Seven cultural themes emerged from the qualitative data: the values placed on health and illness, customary way of life, preference for folk care and the Chinese healthcare system, and factors related to kinship and social ties, religion, economics and education. Dietary change and management in response to illness, including heart failure, is closely related to individuals' cultural background. Healthcare providers should have a good understanding of cultural aspects that can influence patients' conformity to medical recommendations. Heart failure patients need support that considers their cultural needs. Healthcare providers must have a good understanding of the experiences of people from diverse cultural backgrounds. © 2016 John Wiley & Sons Ltd.

  1. Performance and Reliability Analysis of Water Distribution Systems under Cascading Failures and the Identification of Crucial Pipes

    PubMed Central

    Shuang, Qing; Zhang, Mingyuan; Yuan, Yongbo

    2014-01-01

    As a mean of supplying water, Water distribution system (WDS) is one of the most important complex infrastructures. The stability and reliability are critical for urban activities. WDSs can be characterized by networks of multiple nodes (e.g. reservoirs and junctions) and interconnected by physical links (e.g. pipes). Instead of analyzing highest failure rate or highest betweenness, reliability of WDS is evaluated by introducing hydraulic analysis and cascading failures (conductive failure pattern) from complex network. The crucial pipes are identified eventually. The proposed methodology is illustrated by an example. The results show that the demand multiplier has a great influence on the peak of reliability and the persistent time of the cascading failures in its propagation in WDS. The time period when the system has the highest reliability is when the demand multiplier is less than 1. There is a threshold of tolerance parameter exists. When the tolerance parameter is less than the threshold, the time period with the highest system reliability does not meet minimum value of demand multiplier. The results indicate that the system reliability should be evaluated with the properties of WDS and the characteristics of cascading failures, so as to improve its ability of resisting disasters. PMID:24551102

  2. Top-down and bottom-up definitions of human failure events in human reliability analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boring, Ronald Laurids

    2014-10-01

    In the probabilistic risk assessments (PRAs) used in the nuclear industry, human failure events (HFEs) are determined as a subset of hardware failures, namely those hardware failures that could be triggered by human action or inaction. This approach is top-down, starting with hardware faults and deducing human contributions to those faults. Elsewhere, more traditionally human factors driven approaches would tend to look at opportunities for human errors first in a task analysis and then identify which of those errors is risk significant. The intersection of top-down and bottom-up approaches to defining HFEs has not been carefully studied. Ideally, both approachesmore » should arrive at the same set of HFEs. This question is crucial, however, as human reliability analysis (HRA) methods are generalized to new domains like oil and gas. The HFEs used in nuclear PRAs tend to be top-down—defined as a subset of the PRA—whereas the HFEs used in petroleum quantitative risk assessments (QRAs) often tend to be bottom-up—derived from a task analysis conducted by human factors experts. The marriage of these approaches is necessary in order to ensure that HRA methods developed for top-down HFEs are also sufficient for bottom-up applications.« less

  3. Probabilistic Analysis of a Composite Crew Module

    NASA Technical Reports Server (NTRS)

    Mason, Brian H.; Krishnamurthy, Thiagarajan

    2011-01-01

    An approach for conducting reliability-based analysis (RBA) of a Composite Crew Module (CCM) is presented. The goal is to identify and quantify the benefits of probabilistic design methods for the CCM and future space vehicles. The coarse finite element model from a previous NASA Engineering and Safety Center (NESC) project is used as the baseline deterministic analysis model to evaluate the performance of the CCM using a strength-based failure index. The first step in the probabilistic analysis process is the determination of the uncertainty distributions for key parameters in the model. Analytical data from water landing simulations are used to develop an uncertainty distribution, but such data were unavailable for other load cases. The uncertainty distributions for the other load scale factors and the strength allowables are generated based on assumed coefficients of variation. Probability of first-ply failure is estimated using three methods: the first order reliability method (FORM), Monte Carlo simulation, and conditional sampling. Results for the three methods were consistent. The reliability is shown to be driven by first ply failure in one region of the CCM at the high altitude abort load set. The final predicted probability of failure is on the order of 10-11 due to the conservative nature of the factors of safety on the deterministic loads.

  4. A meta-analysis of the association between diabetic patients and AVF failure in dialysis.

    PubMed

    Yan, Yan; Ye, Dan; Yang, Liu; Ye, Wen; Zhan, Dandan; Zhang, Li; Xiao, Jun; Zeng, Yan; Chen, Qinkai

    2018-11-01

    The most preferable vascular access for patients with end-stage renal failure needing hemodialysis is native arteriovenous fistula (AVF) on account of its access longevity, patient morbidity, hospitalization costs, lower risks of infection and fewer incidence of thrombotic complications. Meanwhile, according to National Kidney Foundation (NKF)̸Dialysis Out-comes Quality Initiative (DOQI) guidelines, AVF is more used than before. However, a significant percentage of AVF fails to support dialysis therapy due to lack of adequate maturity. Among all factors, the presence of diabetes mellitus was shown to be one of the risk factors for the development of vascular access failure by some authors. Therefore, this review evaluates the current evidence concerning the correlation of diabetes and AVF failure. A search was conducted using MEDLINE, SCIENCE DIRECT, SPRINGER, WILEY-BLACKWELL, KARGER, EMbase, CNKI and WanFang Data from the establishment time of databases to January 2016. The analysis involved studies that contained subgroups of diabetic patients and compared their outcomes with those of non-diabetic adults. In total, 23 articles were retrieved and included in the review. The meta-analysis revealed a statistically significantly higher rate of AVF failure in diabetic patients compared with non-diabetic patients (OR = 1.682; 95% CI, 1.429-1.981, Test of OR = 1: z = 6.25, p <.001). This review found an increased risk of AVF failure in diabetes patients. If confirmed by further prospective studies, preventive measure should be considered when planning AVF in diabetic patients.

  5. Finite element based damage assessment of composite tidal turbine blades

    NASA Astrophysics Data System (ADS)

    Fagan, Edward M.; Leen, Sean B.; Kennedy, Ciaran R.; Goggins, Jamie

    2015-07-01

    With significant interest growing in the ocean renewables sector, horizontal axis tidal current turbines are in a position to dominate the marketplace. The test devices that have been placed in operation so far have suffered from premature failures, caused by difficulties with structural strength prediction. The goal of this work is to develop methods of predicting the damage level in tidal turbines under their maximum operating tidal velocity. The analysis was conducted using the finite element software package Abaqus; shell models of three representative tidal turbine blades are produced. Different construction methods will affect the damage level in the blade and for this study models were developed with varying hydrofoil profiles. In order to determine the risk of failure, a user material subroutine (UMAT) was created. The UMAT uses the failure criteria designed by Alfred Puck to calculate the risk of fibre and inter-fibre failure in the blades. The results show that degradation of the stiffness is predicted for the operating conditions, having an effect on the overall tip deflection. The failure criteria applied via the UMAT form a useful tool for analysis of high risk regions within the blade designs investigated.

  6. Transient/structural analysis of a combustor under explosive loads

    NASA Technical Reports Server (NTRS)

    Gregory, Peyton B.; Holland, Anne D.

    1992-01-01

    The 8-Foot High Temperature Tunnel (HTT) at NASA Langley Research Center is a combustion-driven blow-down wind tunnel. A major potential failure mode that was considered during the combustor redesign was the possibility of a deflagration and/or detonation in the combustor. If a main burner flame-out were to occur, then unburned fuel gases could accumulate and, if reignited, an explosion could occur. An analysis has been performed to determine the safe operating limits of the combustor under transient explosive loads. The failure criteria was defined and the failure mechanisms were determined for both peak pressures and differential pressure loadings. An overview of the gas dynamics analysis was given. A finite element model was constructed to evaluate 13 transient load cases. The sensitivity of the structure to the frequency content of the transient loading was assessed. In addition, two closed form dynamic analyses were conducted to verify the finite element analysis. It was determined that the differential pressure load or thrust load was the critical load mechanism and that the nozzle is the weak link in the combustor system.

  7. Individual patient meta-analysis of exercise training effects on systemic brain natriuretic peptide expression in heart failure.

    PubMed

    Smart, N A; Meyer, T; Butterfield, J A; Faddy, S C; Passino, C; Malfatto, G; Jonsdottir, S; Sarullo, F; Wisloff, U; Vigorito, C; Giallauria, F

    2012-06-01

    Brain natriuretic peptide (BNP) predicts exercise performance and exercise training may modulate BNP and its N-terminal portion (NT-pro-BNP), we therefore conducted an individual patient analysis of exercise training effects on BNP and NT-pro-BNP. To use an individual patient meta-analysis to relate changes in BNP, NT-pro-BNP, and peak VO(2); to link these changes to volume parameters of exercise training programmes (intensity etc.); and to identify patient characteristics likely to lead to greater improvements in BNP, NT-pro-BNP, and peak VO(2). Individual patient meta-analysis. A systematic search was conducted of Medline (Ovid), Embase.com, Cochrane Central Register of Controlled Trials, and CINAHL (until July 2008) to identify randomized controlled trials of aerobic and/or resistance exercise training in systolic heart failure patients measuring BNP and/or NT-pro-BNP. Primary outcome measures were change in BNP, NT-pro-BNP, and peak VO2. Subanalyses were conducted to identify (1) patient groups that benefit most and (2) exercise programme parameters enhancing favourable changes in primary outcome measures. Ten randomized controlled studies measuring BNP or NT-pro-BNP met eligibility criteria, authors provided individual patient data for 565 patients (313 exercise and 252 controls). Exercise training had favourable effects on BNP (-28.3%, p < 0.0001), NT-pro-BNP (-37.4%, p = < 0.0001), and peak VO(2) (17.8%, p < 0.0001). The analysis showed a significant change in primary outcome measures; moreover, change in BNP (r = -0.31, p < 0.0001) and NT-pro-BNP (r = -0.22, p < 0.0001) were correlated with peak VO(2) change. Exercise training has favourable effects on BNP, NT-pro-BNP, and peak VO(2) in heart failure patients and BNP/NT-pro-BNP changes were correlated with peak VO(2) changes.

  8. Strain gage system evaluation program

    NASA Technical Reports Server (NTRS)

    Dolleris, G. W.; Mazur, H. J.; Kokoszka, E., Jr.

    1978-01-01

    A program was conducted to determine the reliability of various strain gage systems when applied to rotating compressor blades in an aircraft gas turbine engine. A survey of current technology strain gage systems was conducted to provide a basis for selecting candidate systems for evaluation. Testing and evaluation was conducted in an F 100 engine. Sixty strain gage systems of seven different designs were installed on the first and third stages of an F 100 engine fan. Nineteen strain gage failures occurred during 62 hours of engine operation, for a survival rate of 68 percent. Of the failures, 16 occurred at blade-to-disk leadwire jumps (84 percent), two at a leadwire splice (11 percent), and one at a gage splice (5 percent). Effects of erosion, temperature, G-loading, and stress levels are discussed. Results of a post-test analysis of the individual components of each strain gage system are presented.

  9. Evaluation of a Linear Cumulative Damage Failure Model for Epoxy Adhesive

    NASA Technical Reports Server (NTRS)

    Richardson, David E.; Batista-Rodriquez, Alicia; Macon, David; Totman, Peter; McCool, Alex (Technical Monitor)

    2001-01-01

    Recently a significant amount of work has been conducted to provide more complex and accurate material models for use in the evaluation of adhesive bondlines. Some of this has been prompted by recent studies into the effects of residual stresses on the integrity of bondlines. Several techniques have been developed for the analysis of bondline residual stresses. Key to these analyses is the criterion that is used for predicting failure. Residual stress loading of an adhesive bondline can occur over the life of the component. For many bonded systems, this can be several years. It is impractical to directly characterize failure of adhesive bondlines under a constant load for several years. Therefore, alternative approaches for predictions of bondline failures are required. In the past, cumulative damage failure models have been developed. These models have ranged from very simple to very complex. This paper documents the generation and evaluation of some of the most simple linear damage accumulation tensile failure models for an epoxy adhesive. This paper shows how several variations on the failure model were generated and presents an evaluation of the accuracy of these failure models in predicting creep failure of the adhesive. The paper shows that a simple failure model can be generated from short-term failure data for accurate predictions of long-term adhesive performance.

  10. An Example of Concurrent Engineering

    NASA Technical Reports Server (NTRS)

    Rowe, Sidney; Whitten, David; Cloyd, Richard; Coppens, Chris; Rodriguez, Pedro

    1998-01-01

    The Collaborative Engineering Design and Analysis Room (CEDAR) facility allows on-the- spot design review capability for any project during all phases of development. The required disciplines assemble in this facility to work on any problems (analysis, manufacturing, inspection, etc.) associated with a particular design. A small highly focused team of specialists can meet in this room to better expedite the process of developing a solution to an engineering task within the framework of the constraints that are unique to each discipline. This facility provides the engineering tools and translators to develop a concept within the confines of the room or with remote team members that could access the team's data from other locations. The CEDAR area is envisioned as excellent for failure investigation meetings to be conducted where the computer capabilities can be utilized in conjunction with the Smart Board display to develop failure trees, brainstorm failure modes, and evaluate possible solutions.

  11. Benchmarking Commercial Reliability Practices.

    DTIC Science & Technology

    1995-07-01

    companies (70% of total), and to actually receive completed survey forms from 40 companies ( 60 % of participants, 40% of total identified). Reliability...E -20 -30 - A B C D E F G H I J KL MN OP Q R -40 - A = FMEA , B = FTA, C =Thermal Analysis, D = Sneak Circuit Analysis, E = Worst-Case Circuit Analysis...Failure Modes and Effects Analysis ( FMEA ), will be conducted. c. Commercial companies specify the environmental conditions for their products. In doing

  12. Failure mode and effects analysis outputs: are they valid?

    PubMed Central

    2012-01-01

    Background Failure Mode and Effects Analysis (FMEA) is a prospective risk assessment tool that has been widely used within the aerospace and automotive industries and has been utilised within healthcare since the early 1990s. The aim of this study was to explore the validity of FMEA outputs within a hospital setting in the United Kingdom. Methods Two multidisciplinary teams each conducted an FMEA for the use of vancomycin and gentamicin. Four different validity tests were conducted: · Face validity: by comparing the FMEA participants’ mapped processes with observational work. · Content validity: by presenting the FMEA findings to other healthcare professionals. · Criterion validity: by comparing the FMEA findings with data reported on the trust’s incident report database. · Construct validity: by exploring the relevant mathematical theories involved in calculating the FMEA risk priority number. Results Face validity was positive as the researcher documented the same processes of care as mapped by the FMEA participants. However, other healthcare professionals identified potential failures missed by the FMEA teams. Furthermore, the FMEA groups failed to include failures related to omitted doses; yet these were the failures most commonly reported in the trust’s incident database. Calculating the RPN by multiplying severity, probability and detectability scores was deemed invalid because it is based on calculations that breach the mathematical properties of the scales used. Conclusion There are significant methodological challenges in validating FMEA. It is a useful tool to aid multidisciplinary groups in mapping and understanding a process of care; however, the results of our study cast doubt on its validity. FMEA teams are likely to need different sources of information, besides their personal experience and knowledge, to identify potential failures. As for FMEA’s methodology for scoring failures, there were discrepancies between the teams’ estimates and similar incidents reported on the trust’s incident database. Furthermore, the concept of multiplying ordinal scales to prioritise failures is mathematically flawed. Until FMEA’s validity is further explored, healthcare organisations should not solely depend on their FMEA results to prioritise patient safety issues. PMID:22682433

  13. Preoperative radiation and free flap outcomes for head and neck reconstruction: a systematic review and meta-analysis.

    PubMed

    Herle, Pradyumna; Shukla, Lipi; Morrison, Wayne A; Shayan, Ramin

    2015-03-01

    There is a general consensus among reconstructive surgeons that preoperative radiotherapy is associated with a higher risk of flap failure and complications in head and neck surgery. Opinion is also divided regarding the effects of radiation dose on free flap outcomes and timing of preoperative radiation to minimize adverse outcomes. Our meta-analysis will attempt to address these issues. A systematic review of the literature was conducted in concordance to PRISMA protocol. Data were combined using STATA 12 and Open Meta-Analyst software programmes. Twenty-four studies were included comparing 2842 flaps performed in irradiated fields and 3491 flaps performed in non-irradiated fields. Meta-analysis yielded statistically significant risk ratios for flap failure (RR 1.48, P = 0.004), complications (RR 1.84, P < 0.001), reoperation (RR 2.06, P < 0.001) and fistula (RR 2.05, P < 0.001). Mean radiation dose demonstrated a trend towards increased risk of flap failure, but this was not statistically significant. On subgroup analysis, flaps with >60 Gy radiation had a non-statistically significant higher risk of flap failure (RR 1.61, P = 0.145). Preoperative radiation is associated with a statistically significant increased risk of flap complications, failure and fistula. Preoperative radiation in excess of 60 Gy after radiotherapy represents a potential risk factor for increased flap loss and should be avoided where possible. © 2014 Royal Australasian College of Surgeons.

  14. The economic cost of failure in clinical education: a multi-perspective analysis.

    PubMed

    Foo, Jonathan; Rivers, George; Ilic, Dragan; Evans, Darrell J R; Walsh, Kieran; Haines, Terrence; Paynter, Sophie; Morgan, Prue; Lincke, Karl; Lambrou, Haria; Nethercote, Anna; Maloney, Stephen

    2017-07-01

    Failure by students in health professional clinical education intertwines the health and education sectors, with actions in one having potential downstream effects on the other. It is unknown what economic costs are associated with failure, how these costs are distributed, and the impacts these have on students, clinicians and workplace productivity. An understanding of cost drivers and cost boundaries will enable evidence-based targeting of strategic investments into clinical education, including where they should be made and by whom. This study was designed to determine the additional economic costs associated with failure by students in health professional clinical education. A cost analysis study involving cost identification, measurement, valuation and the calculation of total cost was conducted. Costs were considered from the perspective of the student, the education institution, the clinical educator, the health service placement provider organisation and the government. Data were based on a 5-week clinical education programme at Monash University, Australia. Data were collected using quantitative surveys and interviews conducted with health professional students, clinical educators and education institute staff. Reference group representation was also sought at various education institution and health service organisation levels. A transferable model with sensitivity analysis was developed. There is a total additional cost of US$9371 per student failing in clinical education from the perspective of all stakeholders considered. Students bear the majority of this burden, incurring 49% of costs, followed by the government (22%), the education institution (18%), the health service organisation (10%) and the clinical educator (1%). Strong economic links for multiple stakeholders as a result of failure by students in clinical education have been identified. The cost burden is skewed in the direction of students. Any generalisation of these results should be made with consideration for the unique clinical education context in which each health professional education programme operates. © 2017 John Wiley & Sons Ltd and The Association for the Study of Medical Education.

  15. Seminoma at Roswell Park, 1970 to 1979. An analysis of treatment failures.

    PubMed

    Huben, R P; Williams, P D; Pontes, J E; Panahon, A M; Murphy, G P

    1984-04-01

    A retrospective study of all cases of seminoma treated at Roswell Park Memorial Institute from 1970 through 1979 was conducted. Fifty-six evaluable patients treated initially with radiation therapy were seen during this period, and the overall survival rate at an average follow-up period of 52 months was 82%. The survival rate in patients with bulky abdominal or supradiaphragmatic metastases was only 33% (4 of 12 patients). Treatment failures were analyzed to determine their apparent causes and the implication of such failures to the future management of seminoma. The use of combination chemotherapy as the initial treatment modality in advanced seminoma is discussed in light of these results.

  16. Adverse events and treatment failure leading to discontinuation of recently approved antipsychotic drugs in schizophrenia: A network meta-analysis.

    PubMed

    Tonin, Fernanda S; Piazza, Thais; Wiens, Astrid; Fernandez-Llimos, Fernando; Pontarolo, Roberto

    2015-12-01

    Objective:We aimed to gather evidence of the discontinuation rates owing to adverse events or treatment failure for four recently approved antipsychotics (asenapine, blonanserin, iloperidone, and lurasidone).Methods: A systematic review followed by pairwise meta-analysis and mixed treatment comparison meta analysis(MTC) was performed, including randomized controlled trials (RCTs) that compared the use of the above-mentioned drugs versus placebo in patients with schizophrenia. An electronic search was conducted in PubMed, Scopus, Science Direct, Scielo, the Cochrane Library, and International Pharmaceutical Abstracts(January 2015). The included trials were at least single blinded. The main outcome measures extracted were discontinuation owing to adverse events and discontinuation owing to treatment failure.Results: Fifteen RCTs were identified (n = 5400 participants) and 13 of them were amenable for use in our meta-analyses. No significant differences were observed between any of the four drugs and placebo as regards discontinuation owing to adverse events, whether in pairwise meta-analysis or in MTC. All drugs presented a better profile than placebo on discontinuation owing to treatment failure, both in pairwise meta-analysis and MTC. Asenapine was found to be the best therapy in terms of tolerability owing to failure,while lurasidone was the worst treatment in terms of adverse events. The evidence around blonanserin is weak.Conclusion: MTCs allowed the creation of two different rank orders of these four antipsychotic drugs in two outcome measures. This evidence-generating method allows direct and indirect comparisons, supporting approval and pricing decisions when lacking sufficient, direct, head-to-head trials.

  17. Investigation on Failures of Composite Beam and Substrate Concrete due to Drying Shrinkage Property of Repair Materials

    NASA Astrophysics Data System (ADS)

    Pattnaik, Rashmi Ranjan

    2017-06-01

    A Finite Element Analysis (FEA) and an experimental study was conducted on composite beam of repair material and substrate concrete to investigate the failures of the composite beam due to drying shrinkage property of the repair materials. In FEA, the stress distribution in the composite beam due to two concentrate load and shrinkage of repair materials were investigated in addition to the deflected shape of the composite beam. The stress distributions and load deflection shapes of the finite element model were investigated to aid in analysis of the experimental findings. In the experimental findings, the mechanical properties such as compressive strength, split tensile strength, flexural strength, and load-deflection curves were studied in addition to slant shear bond strength, drying shrinkage and failure patterns of the composite beam specimens. Flexure test was conducted to simulate tensile stress at the interface between the repair material and substrate concrete. The results of FEA were used to analyze the experimental results. It was observed that the repair materials with low drying shrinkage are showing compatible failure in the flexure test of the composite beam and deform adequately in the load deflection curves. Also, the flexural strength of the composite beam with low drying shrinkage repair materials showed higher flexural strength as compared to the composite beams with higher drying shrinkage value of the repair materials even though the strength of those materials were more.

  18. Failure mode and effect analysis: improving intensive care unit risk management processes.

    PubMed

    Askari, Roohollah; Shafii, Milad; Rafiei, Sima; Abolhassani, Mohammad Sadegh; Salarikhah, Elaheh

    2017-04-18

    Purpose Failure modes and effects analysis (FMEA) is a practical tool to evaluate risks, discover failures in a proactive manner and propose corrective actions to reduce or eliminate potential risks. The purpose of this paper is to apply FMEA technique to examine the hazards associated with the process of service delivery in intensive care unit (ICU) of a tertiary hospital in Yazd, Iran. Design/methodology/approach This was a before-after study conducted between March 2013 and December 2014. By forming a FMEA team, all potential hazards associated with ICU services - their frequency and severity - were identified. Then risk priority number was calculated for each activity as an indicator representing high priority areas that need special attention and resource allocation. Findings Eight failure modes with highest priority scores including endotracheal tube defect, wrong placement of endotracheal tube, EVD interface, aspiration failure during suctioning, chest tube failure, tissue injury and deep vein thrombosis were selected for improvement. Findings affirmed that improvement strategies were generally satisfying and significantly decreased total failures. Practical implications Application of FMEA in ICUs proved to be effective in proactively decreasing the risk of failures and corrected the control measures up to acceptable levels in all eight areas of function. Originality/value Using a prospective risk assessment approach, such as FMEA, could be beneficial in dealing with potential failures through proposing preventive actions in a proactive manner. The method could be used as a tool for healthcare continuous quality improvement so that the method identifies both systemic and human errors, and offers practical advice to deal effectively with them.

  19. Correction of engineering servicing regularity of transporttechnological machines in operational process

    NASA Astrophysics Data System (ADS)

    Makarova, A. N.; Makarov, E. I.; Zakharov, N. S.

    2018-03-01

    In the article, the issue of correcting engineering servicing regularity on the basis of actual dependability data of cars in operation is considered. The purpose of the conducted research is to increase dependability of transport-technological machines by correcting engineering servicing regularity. The subject of the research is the mechanism of engineering servicing regularity influence on reliability measure. On the basis of the analysis of researches carried out before, a method of nonparametric estimation of car failure measure according to actual time-to-failure data was chosen. A possibility of describing the failure measure dependence on engineering servicing regularity by various mathematical models is considered. It is proven that the exponential model is the most appropriate for that purpose. The obtained results can be used as a separate method of engineering servicing regularity correction with certain operational conditions taken into account, as well as for the technical-economical and economical-stochastic methods improvement. Thus, on the basis of the conducted researches, a method of engineering servicing regularity correction of transport-technological machines in the operational process was developed. The use of that method will allow decreasing the number of failures.

  20. Health assessment of cooling fan bearings using wavelet-based filtering.

    PubMed

    Miao, Qiang; Tang, Chao; Liang, Wei; Pecht, Michael

    2012-12-24

    As commonly used forced convection air cooling devices in electronics, cooling fans are crucial for guaranteeing the reliability of electronic systems. In a cooling fan assembly, fan bearing failure is a major failure mode that causes excessive vibration, noise, reduction in rotation speed, locked rotor, failure to start, and other problems; therefore, it is necessary to conduct research on the health assessment of cooling fan bearings. This paper presents a vibration-based fan bearing health evaluation method using comblet filtering and exponentially weighted moving average. A new health condition indicator (HCI) for fan bearing degradation assessment is proposed. In order to collect the vibration data for validation of the proposed method, a cooling fan accelerated life test was conducted to simulate the lubricant starvation of fan bearings. A comparison between the proposed method and methods in previous studies (i.e., root mean square, kurtosis, and fault growth parameter) was carried out to assess the performance of the HCI. The analysis results suggest that the HCI can identify incipient fan bearing failures and describe the bearing degradation process. Overall, the work presented in this paper provides a promising method for fan bearing health evaluation and prognosis.

  1. Health Assessment of Cooling Fan Bearings Using Wavelet-Based Filtering

    PubMed Central

    Miao, Qiang; Tang, Chao; Liang, Wei; Pecht, Michael

    2013-01-01

    As commonly used forced convection air cooling devices in electronics, cooling fans are crucial for guaranteeing the reliability of electronic systems. In a cooling fan assembly, fan bearing failure is a major failure mode that causes excessive vibration, noise, reduction in rotation speed, locked rotor, failure to start, and other problems; therefore, it is necessary to conduct research on the health assessment of cooling fan bearings. This paper presents a vibration-based fan bearing health evaluation method using comblet filtering and exponentially weighted moving average. A new health condition indicator (HCI) for fan bearing degradation assessment is proposed. In order to collect the vibration data for validation of the proposed method, a cooling fan accelerated life test was conducted to simulate the lubricant starvation of fan bearings. A comparison between the proposed method and methods in previous studies (i.e., root mean square, kurtosis, and fault growth parameter) was carried out to assess the performance of the HCI. The analysis results suggest that the HCI can identify incipient fan bearing failures and describe the bearing degradation process. Overall, the work presented in this paper provides a promising method for fan bearing health evaluation and prognosis. PMID:23262486

  2. Foreign Object Damage to Tires Operating in a Wartime Environment

    DTIC Science & Technology

    1991-11-01

    barriers were successfully overcome and the method of testing employed can now be confidently used for future test needs of this type. Data Analysis ...combined variable effects. Analysis consideration involved cut types, cut depths, number of cuts, cut/hit probabilities, tire failures, and aircraft...November 1988 with data reduction and analysis continuing into October 1989. All of the cutting tests reported in this report were conducted at the

  3. Introduction of the Tools for Economic Analysis of Patient Management Interventions in Heart Failure Costing Tool: a user-friendly spreadsheet program to estimate costs of providing patient-centered interventions.

    PubMed

    Reed, Shelby D; Li, Yanhong; Kamble, Shital; Polsky, Daniel; Graham, Felicia L; Bowers, Margaret T; Samsa, Gregory P; Paul, Sara; Schulman, Kevin A; Whellan, David J; Riegel, Barbara J

    2012-01-01

    Patient-centered health care interventions, such as heart failure disease management programs, are under increasing pressure to demonstrate good value. Variability in costing methods and assumptions in economic evaluations of such interventions limit the comparability of cost estimates across studies. Valid cost estimation is critical to conducting economic evaluations and for program budgeting and reimbursement negotiations. Using sound economic principles, we developed the Tools for Economic Analysis of Patient Management Interventions in Heart Failure (TEAM-HF) Costing Tool, a spreadsheet program that can be used by researchers and health care managers to systematically generate cost estimates for economic evaluations and to inform budgetary decisions. The tool guides users on data collection and cost assignment for associated personnel, facilities, equipment, supplies, patient incentives, miscellaneous items, and start-up activities. The tool generates estimates of total program costs, cost per patient, and cost per week and presents results using both standardized and customized unit costs for side-by-side comparisons. Results from pilot testing indicated that the tool was well-formatted, easy to use, and followed a logical order. Cost estimates of a 12-week exercise training program in patients with heart failure were generated with the costing tool and were found to be consistent with estimates published in a recent study. The TEAM-HF Costing Tool could prove to be a valuable resource for researchers and health care managers to generate comprehensive cost estimates of patient-centered interventions in heart failure or other conditions for conducting high-quality economic evaluations and making well-informed health care management decisions.

  4. Simulation for Prediction of Entry Article Demise (SPEAD): an Analysis Tool for Spacecraft Safety Analysis and Ascent/Reentry Risk Assessment

    NASA Technical Reports Server (NTRS)

    Ling, Lisa

    2014-01-01

    For the purpose of performing safety analysis and risk assessment for a probable offnominal suborbital/orbital atmospheric reentry resulting in vehicle breakup, a synthesis of trajectory propagation coupled with thermal analysis and the evaluation of node failure is required to predict the sequence of events, the timeline, and the progressive demise of spacecraft components. To provide this capability, the Simulation for Prediction of Entry Article Demise (SPEAD) analysis tool was developed. This report discusses the capabilities, modeling, and validation of the SPEAD analysis tool. SPEAD is applicable for Earth or Mars, with the option for 3 or 6 degrees-of-freedom (DOF) trajectory propagation. The atmosphere and aerodynamics data are supplied in tables, for linear interpolation of up to 4 independent variables. The gravitation model can include up to 20 zonal harmonic coefficients. The modeling of a single motor is available and can be adapted to multiple motors. For thermal analysis, the aerodynamic radiative and free-molecular/continuum convective heating, black-body radiative cooling, conductive heat transfer between adjacent nodes, and node ablation are modeled. In a 6- DOF simulation, the local convective heating on a node is a function of Mach, angle-ofattack, and sideslip angle, and is dependent on 1) the location of the node in the spacecraft and its orientation to the flow modeled by an exposure factor, and 2) the geometries of the spacecraft and the node modeled by a heating factor and convective area. Node failure is evaluated using criteria based on melting temperature, reference heat load, g-load, or a combination of the above. The failure of a liquid propellant tank is evaluated based on burnout flux from nucleate boiling or excess internal pressure. Following a component failure, updates are made as needed to the spacecraft mass and aerodynamic properties, nodal exposure and heating factors, and nodal convective and conductive areas. This allows the trajectory to be propagated seamlessly in a single run, inclusive of the trajectories of components that have separated from the spacecraft. The node ablation simulates the decreasing mass and convective/reference areas, and variable heating factor. A built-in database provides the thermo-mechanical properties of For the purpose of performing safety analysis and risk assessment for a probable offnominal suborbital/orbital atmospheric reentry resulting in vehicle breakup, a synthesis of trajectory propagation coupled with thermal analysis and the evaluation of node failure is required to predict the sequence of events, the timeline, and the progressive demise of spacecraft components. To provide this capability, the Simulation for Prediction of Entry Article Demise (SPEAD) analysis tool was developed. This report discusses the capabilities, modeling, and validation of the SPEAD analysis tool. SPEAD is applicable for Earth or Mars, with the option for 3 or 6 degrees-of-freedom (DOF) trajectory propagation. The atmosphere and aerodynamics data are supplied in tables, for linear interpolation of up to 4 independent variables. The gravitation model can include up to 20 zonal harmonic coefficients. The modeling of a single motor is available and can be adapted to multiple motors. For thermal analysis, the aerodynamic radiative and free-molecular/continuum convective heating, black-body radiative cooling, conductive heat transfer between adjacent nodes, and node ablation are modeled. In a 6- DOF simulation, the local convective heating on a node is a function of Mach, angle-ofattack, and sideslip angle, and is dependent on 1) the location of the node in the spacecraft and its orientation to the flow modeled by an exposure factor, and 2) the geometries of the spacecraft and the node modeled by a heating factor and convective area. Node failure is evaluated using criteria based on melting temperature, reference heat load, g-load, or a combination of the above. The failure of a liquid propellant tank is evaluated based on burnout flux from nucleate boiling or excess internal pressure. Following a component failure, updates are made as needed to the spacecraft mass and aerodynamic properties, nodal exposure and heating factors, and nodal convective and conductive areas. This allows the trajectory to be propagated seamlessly in a single run, inclusive of the trajectories of components that have separated from the spacecraft. The node ablation simulates the decreasing mass and convective/reference areas, and variable heating factor. A built-in database provides the thermo-mechanical properties of

  5. NRL Fact Book

    DTIC Science & Technology

    1985-04-01

    characteristics of targets Tank 9.1 m (30 ft) in diameter by 6.7 m (22 ft) deep , automated with computer con- trol and analysis for detailed studies of acoustic...structures; and conducts experiments in the deep ocean, in acoustically shallow water, and in the Arctic. The Division carries out theoretical and...Laser Materials-Application Center Failure Analysis and Fractography Staff Research Activity Areas Environmental Effects Microstructural characterization

  6. Analysis of beam loss induced abort kicker instability

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang W.; Sandberg, J.; Ahrens, L.

    2012-05-20

    Through more than a decade of operation, we have noticed the phenomena of beam loss induced kicker instability in the RHIC beam abort systems. In this study, we analyze the short term beam loss before abort kicker pre-fire events and operation conditions before capacitor failures. Beam loss has caused capacitor failures and elevated radiation level concentrated at failed end of capacitor has been observed. We are interested in beam loss induced radiation and heat dissipation in large oil filled capacitors and beam triggered thyratron conduction. We hope the analysis result would lead to better protection of the abort systems andmore » improved stability of the RHIC operation.« less

  7. A Diagnostic Approach for Electro-Mechanical Actuators in Aerospace Systems

    NASA Technical Reports Server (NTRS)

    Balaban, Edward; Saxena, Abhinav; Bansal, Prasun; Goebel, Kai Frank; Stoelting, Paul; Curran, Simon

    2009-01-01

    Electro-mechanical actuators (EMA) are finding increasing use in aerospace applications, especially with the trend towards all all-electric aircraft and spacecraft designs. However, electro-mechanical actuators still lack the knowledge base accumulated for other fielded actuator types, particularly with regard to fault detection and characterization. This paper presents a thorough analysis of some of the critical failure modes documented for EMAs and describes experiments conducted on detecting and isolating a subset of them. The list of failures has been prepared through an extensive Failure Modes and Criticality Analysis (FMECA) reference, literature review, and accessible industry experience. Methods for data acquisition and validation of algorithms on EMA test stands are described. A variety of condition indicators were developed that enabled detection, identification, and isolation among the various fault modes. A diagnostic algorithm based on an artificial neural network is shown to operate successfully using these condition indicators and furthermore, robustness of these diagnostic routines to sensor faults is demonstrated by showing their ability to distinguish between them and component failures. The paper concludes with a roadmap leading from this effort towards developing successful prognostic algorithms for electromechanical actuators.

  8. Failure Analysis in Platelet Molded Composite Systems

    NASA Astrophysics Data System (ADS)

    Kravchenko, Sergii G.

    Long-fiber discontinuous composite systems in the form of chopped prepreg tapes provide an advanced, structural grade, molding compound allowing for fabrication of complex three-dimensional components. Understanding of process-structure-property relationship is essential for application of prerpeg platelet molded components, especially because of their possible irregular disordered heterogeneous morphology. Herein, a structure-property relationship was analyzed in the composite systems of many platelets. Regular and irregular morphologies were considered. Platelet-based systems with more ordered morphology possess superior mechanical performance. While regular morphologies allow for a careful inspection of failure mechanisms derived from the morphological characteristics, irregular morphologies are representative of the composite architectures resulting from uncontrolled deposition and molding with chopped prerpegs. Progressive failure analysis (PFA) was used to study the damaged deformation up to ultimate failure in a platelet-based composite system. Computational damage mechanics approaches were utilized to conduct the PFA. The developed computational models granted understanding of how the composite structure details, meaning the platelet geometry and system morphology (geometrical arrangement and orientation distribution of platelets), define the effective mechanical properties of a platelet-molded composite system, its stiffness, strength and variability in properties.

  9. Failure Mode and Effect Analysis (FMEA) may enhance implementation of clinical practice guidelines: An experience from the Middle East.

    PubMed

    Babiker, Amir; Amer, Yasser S; Osman, Mohamed E; Al-Eyadhy, Ayman; Fatani, Solafa; Mohamed, Sarar; Alnemri, Abdulrahman; Titi, Maher A; Shaikh, Farheen; Alswat, Khalid A; Wahabi, Hayfaa A; Al-Ansary, Lubna A

    2018-02-01

    Implementation of clinical practice guidelines (CPGs) has been shown to reduce variation in practice and improve health care quality and patients' safety. There is a limited experience of CPG implementation (CPGI) in the Middle East. The CPG program in our institution was launched in 2009. The Quality Management department conducted a Failure Mode and Effect Analysis (FMEA) for further improvement of CPGI. This is a prospective study of a qualitative/quantitative design. Our FMEA included (1) process review and recording of the steps and activities of CPGI; (2) hazard analysis by recording activity-related failure modes and their effects, identification of actions required, assigned severity, occurrence, and detection scores for each failure mode and calculated the risk priority number (RPN) by using an online interactive FMEA tool; (3) planning: RPNs were prioritized, recommendations, and further planning for new interventions were identified; and (4) monitoring: after reduction or elimination of the failure mode. The calculated RPN will be compared with subsequent analysis in post-implementation phase. The data were scrutinized from a feedback of quality team members using a FMEA framework to enhance the implementation of 29 adapted CPGs. The identified potential common failure modes with the highest RPN (≥ 80) included awareness/training activities, accessibility of CPGs, fewer advocates from clinical champions, and CPGs auditing. Actions included (1) organizing regular awareness activities, (2) making CPGs printed and electronic copies accessible, (3) encouraging senior practitioners to get involved in CPGI, and (4) enhancing CPGs auditing as part of the quality sustainability plan. In our experience, FMEA could be a useful tool to enhance CPGI. It helped us to identify potential barriers and prepare relevant solutions. © 2017 John Wiley & Sons, Ltd.

  10. Analysis of a Hybrid Wing Body Center Section Test Article

    NASA Technical Reports Server (NTRS)

    Wu, Hsi-Yung T.; Shaw, Peter; Przekop, Adam

    2013-01-01

    The hybrid wing body center section test article is an all-composite structure made of crown, floor, keel, bulkhead, and rib panels utilizing the Pultruded Rod Stitched Efficient Unitized Structure (PRSEUS) design concept. The primary goal of this test article is to prove that PRSEUS components are capable of carrying combined loads that are representative of a hybrid wing body pressure cabin design regime. This paper summarizes the analytical approach, analysis results, and failure predictions of the test article. A global finite element model of composite panels, metallic fittings, mechanical fasteners, and the Combined Loads Test System (COLTS) test fixture was used to conduct linear structural strength and stability analyses to validate the specimen under the most critical combination of bending and pressure loading conditions found in the hybrid wing body pressure cabin. Local detail analyses were also performed at locations with high stress concentrations, at Tee-cap noodle interfaces with surrounding laminates, and at fastener locations with high bearing/bypass loads. Failure predictions for different composite and metallic failure modes were made, and nonlinear analyses were also performed to study the structural response of the test article under combined bending and pressure loading. This large-scale specimen test will be conducted at the COLTS facility at the NASA Langley Research Center.

  11. Characteristics of early versus late implant failure: a retrospective study.

    PubMed

    Manor, Yifat; Oubaid, Saheer; Mardinger, Ofer; Chaushu, Gavriel; Nissan, Joseph

    2009-12-01

    Implant failures can be divided into early and late according to the timing of failure. The purpose of this study was to characterize and compare both types. A retrospective cohort study was conducted in 194 patients (98 men and 96 women) who presented after dental implant failures during a 6-year period (2000 to 2006). The patient served as the unit of analysis. A history of at least 1 failed and removed dental implant served as the inclusion criterion. Patients were excluded from this study whenever their files had missing data. The collected data included a patient's characteristics, failure characteristics, and the anatomic status of the alveolar ridge after failure. Late failures were associated with moderate to severe bone loss, a larger number of failed implants per patient, a higher incidence in men, and mostly in posterior areas. Early failures were associated with minimal bone loss, occurred more in women, at a younger age, and in most cases the implants were intended to support single crowns. Meticulous follow-up is needed to reveal and treat failing or ailing implants. Once established as hopeless, they should be removed as soon as possible to prevent further bone loss.

  12. Functional electrical stimulation for chronic heart failure: a meta-analysis.

    PubMed

    Smart, Neil A; Dieberg, Gudrun; Giallauria, Francesco

    2013-07-15

    We conducted a meta-analysis of randomized, controlled trials of combined electrical stimulation versus conventional exercise training or placebo control in heart failure patients. A systematic search was conducted of Medline (Ovid) (1950-September 2011), Embase.com (1974-September 2011), Cochrane Central Register of Controlled Trials and CINAHL (1981-September 2011). The search strategy included a mix of MeSH and free text terms for the key concepts heart failure, exercise training and functional electrical stimulation (FES). FES produced inferior improvements in peak VO2 when compared to cycle training: mean difference (MD) -0.32 ml.kg(-1).min(-1) (95% C.I. -0.63 to -0.02 ml.kg(-1).min(-1), p=0.04), however FES elicited superior improvements in peak VO2: MD 2.30 ml.kg(-1).min(-1) (95% C.I. 1.98 to 2.62 ml.kg(-1).min(-1), p<0.00001); and six minute walk distance to sedentary care or sham FES; MD 46.9 m (95% C.I. 22.5 to 71.3m, p=0.0002). There was no difference in change in quality of life between cycling and FES, but FES elicited significantly larger improvements in Minnesota Living with Heart Failure score than placebo or sham treatment; MD 1.15 (95% C.I. 0.69 to 1.61, p<0.00001). Moreover, the total FES intervention hours were strongly correlated with change in peak VO2, (r=0.80, p=0.02). Passive or active exercise is beneficial for patients with moderate to severe heart failure, but active cycling, or other aerobic/resistance activity is preferred in patients with heart failure who are able to exercise, and FES is the preferred modality in those unable to actively exercise. The benefits of FES may however, be smaller than those observed in conventional exercise training. Aggregate hours of electrical stimulation therapy were associated with larger improvements in cardio-respiratory fitness. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  13. Azithromycin treatment failure for Chlamydia trachomatis among heterosexual men with nongonococcal urethritis

    PubMed Central

    Kissinger, Patricia; White, Scott; Manhart, Lisa E.; Schwebke, Jane; Taylor, Stephanie N; Mena, Leandro; Khosropour, Christine M; Wilcox, Larissa; Schmidt, Norine; Martin, David H

    2016-01-01

    Background Three recent prospective studies have suggested that the 1 g dose of azithromycin for Chlamydia trachomatis (Ct) was less effective than expected, reporting a wide range of treatment failure rates (5.8%–22.6%). Reasons for the disparate results could be attributed to geographic or methodological differences. The purpose of this study was to re-examine the studies and attempt to harmonize methodologies to reduce misclassification as a result of false positives from early test-of-cure (TOC) or reinfection as a result of sexual exposure rather than treatment failure. Methods Men who had sex with women, who received 1 g azithromycin under directly observed therapy (DOT) for presumptive treatment of nongonococcal urethritis (NGU) with confirmed Ct were included. Baseline screening was performed on urethral swabs or urine and TOC screening was performed on urine using nucleic acid amplification tests (NAAT). Post-treatment vaginal sexual exposure was elicited at TOC. Data from the three studies was obtained and re-analyzed. Rates of Ct re-test positive were examined for all cases and a sensitivity analysis was conducted to either reclassify potential false positives/reinfections as negative or remove them from the analysis. Results The crude treatment failure rate was 12.8% (31/242). The rate when potential false positives/reinfections were reclassified as negative was 6.2% (15/242) or when these were excluded from analysis was 10.9% (15/138). Conclusion In these samples of men who have sex with women with Ct-related NGU, azithromycin treatment failure was between 6.2% and 12.8%. This range of failure is lower than previously published but higher than the desired World Health Organization’s target chlamydia treatment failure rate of < 5%. PMID:27631353

  14. Azithromycin Treatment Failure for Chlamydia trachomatis Among Heterosexual Men With Nongonococcal Urethritis.

    PubMed

    Kissinger, Patricia J; White, Scott; Manhart, Lisa E; Schwebke, Jane; Taylor, Stephanie N; Mena, Leandro; Khosropour, Christine M; Wilcox, Larissa; Schmidt, Norine; Martin, David H

    2016-10-01

    Three recent prospective studies have suggested that the 1-g dose of azithromycin for Chlamydia trachomatis (Ct) was less effective than expected, reporting a wide range of treatment failure rates (5.8%-22.6%). Reasons for the disparate results could be attributed to geographic or methodological differences. The purpose of this study was to reexamine the studies and attempt to harmonize methodologies to reduce misclassification as a result of false positives from early test-of-cure (TOC) or reinfection as a result of sexual exposure rather than treatment failure. Men who had sex with women, who received 1-g azithromycin under directly observed therapy for presumptive treatment of nongonococcal urethritis with confirmed Ct were included. Baseline screening was performed on urethral swabs or urine, and TOC screening was performed on urine using nucleic acid amplification tests. Posttreatment vaginal sexual exposure was elicited at TOC. Data from the 3 studies were obtained and reanalyzed. Rates of Ct retest positive were examined for all cases, and a sensitivity analysis was conducted to either reclassify potential false positives/reinfections as negative or remove them from the analysis. The crude treatment failure rate was 12.8% (31/242). The rate when potential false positives/reinfections were reclassified as negative was 6.2% (15/242) or when these were excluded from analysis was 10.9% (15/138). In these samples of men who have sex with women with Ct-related nongonococcal urethritis, azithromycin treatment failure was between 6.2% and 12.8%. This range of failure is lower than previously published but higher than the desired World Health Organization's target chlamydia treatment failure rate of < 5%.

  15. Efficient Simulation and Abuse Modeling of Mechanical-Electrochemical-Thermal Phenomena in Lithium-Ion Batteries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Santhanagopalan, Shriram; Smith, Kandler A; Graf, Peter A

    NREL's Energy Storage team is exploring the effect of mechanical crush of lithium ion cells on their thermal and electrical safety. PHEV cells, fresh as well as ones aged over 8 months under different temperatures, voltage windows, and charging rates, were subjected to destructive physical analysis. Constitutive relationship and failure criteria were developed for the electrodes, separator as well as packaging material. The mechanical models capture well, the various modes of failure across different cell components. Cell level validation is being conducted by Sandia National Laboratories.

  16. Thermal design, analysis and comparison on three concepts of space solar power satellite

    NASA Astrophysics Data System (ADS)

    Yang, Chen; Hou, Xinbin; Wang, Li

    2017-08-01

    Space solar power satellites (SSPS) have been widely studied as systems for collecting solar energy in space and transmitting it wirelessly to earth. A previously designed planar SSPS concept collects solar power in two huge arrays and then transmits it through one side of the power-conduction joint to the antenna. However, the system's one group of power-conduction joints may induce a single point of failure. As an SSPS concept, the module symmetrical concentrator (MSC) architecture has many advantages. This architecture can help avoid the need for a large, potentially failure-prone conductive rotating joint and limit wiring mass. However, the thermal control system has severely restricted the rapid development of MSC, especially in the sandwich module. Because of the synchronous existence of five suns concentration and solar external heat flux, the sandwich module will have a very high temperature, which will surpass the permissible temperature of the solar cells. Recently, an alternate multi-rotary joints (MR) SSPS concept was designed by the China Academy of Space Technology (CAST). This system has multiple joints to avoid the problem of a single point of failure. Meanwhile, this concept has another advantage for reducing the high power and heat removal in joints. It is well known to us that, because of the huge external flux in SSPS, the thermal management sub-system is an important component that cannot be neglected. Based on the three SSPS concepts, this study investigated the thermal design and analysis of a 1-km, gigawatt-level transmitting antenna in SSPS. This study compares the thermal management sub-systems of power-conduction joints in planar and MR SSPS. Moreover, the study considers three classic thermal control architectures of the MSC's sandwich module: tile, step, and separation. The study also presents an elaborate parameter design, analysis and discussion of step architecture. Finally, the results show the thermal characteristics of each SSPS concept, and the three concepts are compared. The design layouts, analysis results and parameter discussions of the thermal management sub-system proposed in this study can help inform future SSPS thermal designs.

  17. The fluoroscopy time, door to balloon time, contrast volume use and prevalence of vascular access site failure with transradial versus transfemoral approach in ST segment elevation myocardial infarction: A systematic review & meta-analysis.

    PubMed

    Singh, Sukhchain; Singh, Mukesh; Grewal, Navsheen; Khosla, Sandeep

    2015-12-01

    The authors aimed to conduct first systematic review and meta-analysis in STEMI patients evaluating vascular access site failure rate, fluoroscopy time, door to balloon time and contrast volume used with transradial vs transfemoral approach (TRA vs TFA) for PCI. The PubMed, CINAHL, clinicaltrials.gov, Embase and CENTRAL databases were searched for randomized trials comparing TRA versus TFA. Random effect models were used to conduct this meta-analysis. Fourteen randomized trials comprising 3758 patients met inclusion criteria. The access site failure rate was significantly higher TRA compared to TFA (RR 3.30, CI 2.16-5.03; P=0.000). Random effect inverse variance weighted prevalence rate meta-analysis showed that access site failure rate was predicted to be 4% (95% CI 3.0-6.0%) with TRA versus 1% (95% CI 0.0-1.0 %) with TFA. Door to balloon time (Standardized mean difference [SMD] 0.30 min, 95% CI 0.23-0.37 min; P=0.000) and fluoroscopy time (Standardized mean difference 0.14 min, 95% CI 0.06-0.23 min; P=0.001) were also significantly higher in TRA. There was no difference in the amount of contrast volume used with TRA versus TFA (SMD -0.05 ml, 95% CI -0.14 to 0.04 ml; P=0.275). Statistical heterogeneity was low in cross-over rate and contrast volume use, moderate in fluoroscopy time but high in the door to balloon time comparison. Operators need to consider higher cross-over rate with TRA compared to TFA in STEMI patients while attempting PCI. Fluoroscopy and door to balloon times are negligibly higher with TRA but there is no difference in terms of contrast volume use. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Factors Determining the Success and Failure of eHealth Interventions: Systematic Review of the Literature.

    PubMed

    Granja, Conceição; Janssen, Wouter; Johansen, Monika Alise

    2018-05-01

    eHealth has an enormous potential to improve healthcare cost, effectiveness, and quality of care. However, there seems to be a gap between the foreseen benefits of research and clinical reality. Our objective was to systematically review the factors influencing the outcome of eHealth interventions in terms of success and failure. We searched the PubMed database for original peer-reviewed studies on implemented eHealth tools that reported on the factors for the success or failure, or both, of the intervention. We conducted the systematic review by following the patient, intervention, comparison, and outcome framework, with 2 of the authors independently reviewing the abstract and full text of the articles. We collected data using standardized forms that reflected the categorization model used in the qualitative analysis of the outcomes reported in the included articles. Among the 903 identified articles, a total of 221 studies complied with the inclusion criteria. The studies were heterogeneous by country, type of eHealth intervention, method of implementation, and reporting perspectives. The article frequency analysis did not show a significant discrepancy between the number of reports on failure (392/844, 46.5%) and on success (452/844, 53.6%). The qualitative analysis identified 27 categories that represented the factors for success or failure of eHealth interventions. A quantitative analysis of the results revealed the category quality of healthcare (n=55) as the most mentioned as contributing to the success of eHealth interventions, and the category costs (n=42) as the most mentioned as contributing to failure. For the category with the highest unique article frequency, workflow (n=51), we conducted a full-text review. The analysis of the 23 articles that met the inclusion criteria identified 6 barriers related to workflow: workload (n=12), role definition (n=7), undermining of face-to-face communication (n=6), workflow disruption (n=6), alignment with clinical processes (n=2), and staff turnover (n=1). The reviewed literature suggested that, to increase the likelihood of success of eHealth interventions, future research must ensure a positive impact in the quality of care, with particular attention given to improved diagnosis, clinical management, and patient-centered care. There is a critical need to perform in-depth studies of the workflow(s) that the intervention will support and to perceive the clinical processes involved. ©Conceição Granja, Wouter Janssen, Monika Alise Johansen. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 01.05.2018.

  19. Factors Determining the Success and Failure of eHealth Interventions: Systematic Review of the Literature

    PubMed Central

    Janssen, Wouter; Johansen, Monika Alise

    2018-01-01

    Background eHealth has an enormous potential to improve healthcare cost, effectiveness, and quality of care. However, there seems to be a gap between the foreseen benefits of research and clinical reality. Objective Our objective was to systematically review the factors influencing the outcome of eHealth interventions in terms of success and failure. Methods We searched the PubMed database for original peer-reviewed studies on implemented eHealth tools that reported on the factors for the success or failure, or both, of the intervention. We conducted the systematic review by following the patient, intervention, comparison, and outcome framework, with 2 of the authors independently reviewing the abstract and full text of the articles. We collected data using standardized forms that reflected the categorization model used in the qualitative analysis of the outcomes reported in the included articles. Results Among the 903 identified articles, a total of 221 studies complied with the inclusion criteria. The studies were heterogeneous by country, type of eHealth intervention, method of implementation, and reporting perspectives. The article frequency analysis did not show a significant discrepancy between the number of reports on failure (392/844, 46.5%) and on success (452/844, 53.6%). The qualitative analysis identified 27 categories that represented the factors for success or failure of eHealth interventions. A quantitative analysis of the results revealed the category quality of healthcare (n=55) as the most mentioned as contributing to the success of eHealth interventions, and the category costs (n=42) as the most mentioned as contributing to failure. For the category with the highest unique article frequency, workflow (n=51), we conducted a full-text review. The analysis of the 23 articles that met the inclusion criteria identified 6 barriers related to workflow: workload (n=12), role definition (n=7), undermining of face-to-face communication (n=6), workflow disruption (n=6), alignment with clinical processes (n=2), and staff turnover (n=1). Conclusions The reviewed literature suggested that, to increase the likelihood of success of eHealth interventions, future research must ensure a positive impact in the quality of care, with particular attention given to improved diagnosis, clinical management, and patient-centered care. There is a critical need to perform in-depth studies of the workflow(s) that the intervention will support and to perceive the clinical processes involved. PMID:29716883

  20. Novel 18650 lithium-ion battery surrogate cell design with anisotropic thermophysical properties for studying failure events

    NASA Astrophysics Data System (ADS)

    Spinner, Neil S.; Hinnant, Katherine M.; Mazurick, Ryan; Brandon, Andrew; Rose-Pehrsson, Susan L.; Tuttle, Steven G.

    2016-04-01

    Cylindrical 18650-type surrogate cells were designed and fabricated to mimic the thermophysical properties and behavior of active lithium-ion batteries. An internal jelly roll geometry consisting of alternating stainless steel and mica layers was created, and numerous techniques were used to estimate thermophysical properties. Surrogate cell density was measured to be 1593 ± 30 kg/m3, and heat capacity was found to be 727 ± 18 J/kg-K. Axial thermal conductivity was determined to be 5.1 ± 0.6 W/m-K, which was over an order of magnitude higher than radial thermal conductivity due to jelly roll anisotropy. Radial heating experiments were combined with numerical and analytical solutions to the time-dependent, radial heat conduction equation, and from the numerical method an additional estimate for heat capacity of 805 ± 23 J/kg-K was found. Using both heat capacities and analysis techniques, values for radial thermal conductivity were between 0.120 and 0.197 W/m-K. Under normal operating conditions, relatively low radial temperature distributions were observed; however, during extreme battery failure with a hexagonal cell package, instantaneous radial temperature distributions as high as 43-71 °C were seen. For a vertical cell package, even during adjacent cell failure, similar homogeneity in internal temperatures were observed, demonstrating thermal anisotropy.

  1. The effect of renin-angiotensin system inhibitors on mortality and heart failure hospitalization in patients with heart failure and preserved ejection fraction: a systematic review and meta-analysis.

    PubMed

    Shah, Ravi V; Desai, Akshay S; Givertz, Michael M

    2010-03-01

    Although renin-angiotensin system (RAS) inhibitors have little demonstrable effect on mortality in patients with heart failure and preserved ejection fraction (HF-PEF), some trials have suggested a benefit with regard to reduction in HF hospitalization. Here, we systematically review and evaluate prospective clinical studies of RAS inhibitors enrolling patients with HF-PEF, including the 3 major trials of RAS inhibition (Candesartan in Patients with Chronic Heart Failure and Preserved Left Ventricular Ejection Fraction [CHARM-Preserved], Irbesartan in Patients with Heart Failure and Preserved Ejection Fraction [I-PRESERVE], and Perindopril in Elderly People with Chronic Heart Failure [PEP-CHF]). We also conducted a pooled analysis of 8021 patients in the 3 major randomized trials of RAS inhibition in HF-PEF (CHARM-Preserved, I-PRESERVE, and PEP-CHF) in fixed-effect models, finding no clear benefit with regard to all-cause mortality (odds ratio [OR] 1.03, 95% confidence interval [CI], 0.92-1.15; P=.62), or HF hospitalization (OR 0.90, 95% CI 0.80-1.02; P=.09). Although RAS inhibition may be valuable in the management of comorbidities related to HF-PEF, RAS inhibition in HF-PEF is not associated with consistent reduction in HF hospitalization or mortality in this emerging cohort. Copyright (c) 2010 Elsevier Inc. All rights reserved.

  2. The struggling student: a thematic analysis from the self-regulated learning perspective.

    PubMed

    Patel, Rakesh; Tarrant, Carolyn; Bonas, Sheila; Yates, Janet; Sandars, John

    2015-04-01

    Students who engage in self-regulated learning (SRL) are more likely to achieve academic success compared with students who have deficits in SRL and tend to struggle with academic performance. Understanding how poor SRL affects the response to failure at assessment will inform the development of better remediation. Semi-structured interviews were conducted with 55 students who had failed the final re-sit assessment at two medical schools in the UK to explore their use of SRL processes. A thematic analysis approach was used to identify the factors, from an SRL perspective, that prevented students from appropriately and adaptively overcoming failure, and confined them to a cycle of recurrent failure. Struggling students did not utilise key SRL processes, which caused them to make inappropriate choices of learning strategies for written and clinical formats of assessment, and to use maladaptive strategies for coping with failure. Their normalisation of the experience and external attribution of failure represented barriers to their taking up of formal support and seeking informal help from peers. This study identified that struggling students had problems with SRL, which caused them to enter a cycle of failure as a result of their limited attempts to access formal and informal support. Implications for how medical schools can create a culture that supports the seeking of help and the development of SRL, and improves remediation for struggling students, are discussed. © 2015 John Wiley & Sons Ltd.

  3. Safety assessment of historical masonry churches based on pre-assigned kinematic limit analysis, FE limit and pushover analyses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Milani, Gabriele, E-mail: milani@stru.polimi.it; Valente, Marco, E-mail: milani@stru.polimi.it

    2014-10-06

    This study presents some results of a comprehensive numerical analysis on three masonry churches damaged by the recent Emilia-Romagna (Italy) seismic events occurred in May 2012. The numerical study comprises: (a) pushover analyses conducted with a commercial code, standard nonlinear material models and two different horizontal load distributions; (b) FE kinematic limit analyses performed using a non-commercial software based on a preliminary homogenization of the masonry materials and a subsequent limit analysis with triangular elements and interfaces; (c) kinematic limit analyses conducted in agreement with the Italian code and based on the a-priori assumption of preassigned failure mechanisms, where themore » masonry material is considered unable to withstand tensile stresses. All models are capable of giving information on the active failure mechanism and the base shear at failure, which, if properly made non-dimensional with the weight of the structure, gives also an indication of the horizontal peak ground acceleration causing the collapse of the church. The results obtained from all three models indicate that the collapse is usually due to the activation of partial mechanisms (apse, façade, lateral walls, etc.). Moreover the horizontal peak ground acceleration associated to the collapse is largely lower than that required in that seismic zone by the Italian code for ordinary buildings. These outcomes highlight that structural upgrading interventions would be extremely beneficial for the considerable reduction of the seismic vulnerability of such kind of historical structures.« less

  4. Phrenic Nerve Conduction Study in the Early Stage of Guillain-Barre Syndrome as a Predictor of Respiratory Failure.

    PubMed

    Sen, Barun Kumar; Pandit, Alak

    2018-01-01

    Guillain-Barré syndrome (GBS) has unpredictable clinical course with severe complication of respiratory failure. To identify clinical profiles and electrophysiological study particularly non-invasive Phrenic nerve conduction study in patients of early GBS to predict respiratory failure. 64 adult (age≥18yrs) patients of early GBS (onset ≤ 14 days) during the study period from January 2014 to October 2015 were evaluated by clinical profiles of age, gender, antecedent infection, time to peak disability, single breath counts, cranial nerve involvement, autonomic dysfunction and non-invasive Phrenic nerve conduction study. Patients with predisposition factors of polyneuropathy like diabetes mellitus, hypothyroidism, vitamin deficiency, renal failure were excluded. Among 64 patients abnormal phrenic nerve conduction study was seen in 65.62% cases (42/64) and 45.23% (19/42) of them developed respiratory failure. Phrenic nerve sum latency, amplitude, duration and area were abnormal in those who developed respiratory failure and they had sum of phrenic nerve latency >28 msec, sum of CMAP amplitude <300 μV, sum of CMAP duration >50 msec and sum of area < 4 mVmS. None with normal phrenic nerve study developed respiratory failure. It was found that age, gender, preceding infection, autonomic involvement and types of GB syndrome had no influence on development of respiratory failure (p>0.05). Rapid disease progression to peak disability, more severe disease, shorter single breath counts and cranial nerve involvement were seen more often in patients with respiratory failure. Abnormal Phrenic nerve conduction study in the early Guillain-Barré syndrome might be of great value independently in predicting impending respiratory failure.

  5. Phrenic Nerve Conduction Study in the Early Stage of Guillain–Barre Syndrome as a Predictor of Respiratory Failure

    PubMed Central

    Sen, Barun Kumar; Pandit, Alak

    2018-01-01

    Background: Guillain-Barré syndrome (GBS) has unpredictable clinical course with severe complication of respiratory failure. Objective: To identify clinical profiles and electrophysiological study particularly non-invasive Phrenic nerve conduction study in patients of early GBS to predict respiratory failure. Methods: 64 adult (age≥18yrs) patients of early GBS (onset ≤ 14 days) during the study period from January 2014 to October 2015 were evaluated by clinical profiles of age, gender, antecedent infection, time to peak disability, single breath counts, cranial nerve involvement, autonomic dysfunction and non-invasive Phrenic nerve conduction study. Patients with predisposition factors of polyneuropathy like diabetes mellitus, hypothyroidism, vitamin deficiency, renal failure were excluded. Results: Among 64 patients abnormal phrenic nerve conduction study was seen in 65.62% cases (42/64) and 45.23% (19/42) of them developed respiratory failure. Phrenic nerve sum latency, amplitude, duration and area were abnormal in those who developed respiratory failure and they had sum of phrenic nerve latency >28 msec, sum of CMAP amplitude <300 μV, sum of CMAP duration >50 msec and sum of area < 4 mVmS. None with normal phrenic nerve study developed respiratory failure. It was found that age, gender, preceding infection, autonomic involvement and types of GB syndrome had no influence on development of respiratory failure (p>0.05). Rapid disease progression to peak disability, more severe disease, shorter single breath counts and cranial nerve involvement were seen more often in patients with respiratory failure. Conclusion: Abnormal Phrenic nerve conduction study in the early Guillain-Barré syndrome might be of great value independently in predicting impending respiratory failure. PMID:29720799

  6. Failure modes of Y-TZP abutments with external hex implant-abutment connection determined by fractographic analysis.

    PubMed

    Basílio, Mariana de Almeida; Delben, Juliana Aparecida; Cesar, Paulo Francisco; Rizkalla, Amin Sami; Santos Junior, Gildo Coelho; Arioli Filho, João Neudenir

    2016-07-01

    Yttria-stabilized tetragonal zirconia (Y-TZP) was introduced as ceramic implant abutments due to its excellent mechanical properties. However, the damage patterns for Y-TZP abutments are limited in the literature. Fractographic analyses can provide insights as to the failure origin and related mechanisms. The purpose of this study was to analyze fractured Y-TZP abutments to establish fractographic patterns and then possible reasons for failure. Thirty two prefabricated Y-TZP abutments on external hex implants were retrieved from a single-load-to failure test according to the ISO 14801. Fractographic analyses were conducted under polarized-light estereo and scanning electro microscopy. The predominant fracture pattern was abutment fracture at the connecting region. Classic fractographic features such as arrest lines, hackle, and twist hackle established that failure started where Y-TZP abutments were in contact with the retention screw edges. The abutment screw design and the loading point were the reasons for localized stress concentration and fracture patterns. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Operating Experience and Reliability Improvements on the 5 kW CW Klystron at Jefferson Lab

    NASA Astrophysics Data System (ADS)

    Nelson, R.; Holben, S.

    1997-05-01

    With substantial operating hours on the RF system, considerable information on reliability of the 5 kW CW klystrons has been obtained. High early failure rates led to examination of the operating conditions and failure modes. Internal ceramic contamination caused premature failure of gun potting material and ultimate tube demise through arcing or ceramic fracture. A planned course of repotting and reconditioning of approximately 300 klystrons, plus careful attention to operating conditions and periodic analysis of operational data, has substantially reduced the failure rate. It is anticipated that implementation of planned supplemental monitoring systems for the klystrons will allow most catastrophic failures to be avoided. By predicting end of life, tubes can be changed out before they fail, thus minimizing unplanned downtime. Initial tests have also been conducted on this same klystron operated at higher voltages with resultant higher output power. The outcome of these tests will provide information to be considered for future upgrades to the accelerator.

  8. Use of histamine H2 receptor antagonists and outcomes in patients with heart failure: a nationwide population-based cohort study.

    PubMed

    Adelborg, Kasper; Sundbøll, Jens; Schmidt, Morten; Bøtker, Hans Erik; Weiss, Noel S; Pedersen, Lars; Sørensen, Henrik Toft

    2018-01-01

    Histamine H 2 receptor activation promotes cardiac fibrosis and apoptosis in mice. However, the potential effectiveness of histamine H 2 receptor antagonists (H2RAs) in humans with heart failure is largely unknown. We examined the association between H2RA initiation and all-cause mortality among patients with heart failure. Using Danish medical registries, we conducted a nationwide population-based active-comparator cohort study of new users of H2RAs and proton pump inhibitors (PPIs) after first-time hospitalization for heart failure during the period 1995-2014. Hazard ratios (HRs) for all-cause mortality and hospitalization due to worsening of heart failure, adjusting for age, sex, and time between heart failure diagnosis and initiation of PPI or H2RA therapy, index year, comorbidity, cardiac surgery, comedications, and socioeconomic status were computed based on Cox regression analysis. Our analysis included 42,902 PPI initiators (median age 78 years, 46% female) and 3,296 H2RA initiators (median age 76 years, 48% female). Mortality risk was lower among H2RA initiators than PPI initiators after 1 year (26% vs 31%) and 5 years (60% vs 66%). In multivariable analyses, the 1-year HR was 0.80 (95% CI, 0.74-0.86) and the 5-year HR was 0.85 (95% CI, 0.80-0.89). These findings were consistent after propensity score matching and for ischemic and nonischemic heart failure, as for sex and age groups. The rate of hospitalization due to worsening of heart failure was lower among H2RA initiators than PPI initiators. In patients with heart failure, H2RA initiation was associated with 15%-20% lower mortality than PPI initiation.

  9. Medical costs associated with non-Hodgkin's lymphoma in the United States during the first two years of treatment.

    PubMed

    Kutikova, Lucie; Bowman, Lee; Chang, Stella; Long, Stacey R; Arning, Michael; Crown, William H

    2006-08-01

    To determine the direct costs of medical care associated with aggressive and indolent non-Hodgkin's lymphoma (NHL) in the United States; to show how costs for aggressive NHL change over time by examining costs related to initial, secondary and palliative treatment phases; and to evaluate the economic consequences of treatment failure in aggressive NHL. A retrospective cohort analysis of 1999 - 2000 direct costs in newly diagnosed NHL patients and controls (subjects without any cancer) was conducted using the MarketScan medical and drug claims database of large employers across the United States. Treatment failure analysis was conducted for aggressive NHL patients, and was defined by the need for secondary treatment or palliative care after initial therapy. Cost of treatment failure was calculated as difference in regression-adjusted costs between patients with initial therapy only and patients experiencing initial treatment failure. Patients with aggressive (n = 356) and indolent (n = 698) NHL had significantly greater health service utilization and associated costs (all P < 05) than controls (n = 1068 for aggressive, n = 2094 for indolent). Mean monthly costs were 5871 dollars for aggressive NHL vs. 355 dollars for controls (P < 0001) and 3833 dollars for indolent NHL vs. 289 dollars for controls (P < 0001). The primary cost drivers were hospitalization (aggressive NHL = 44% of total costs, indolent NHL = 50%) and outpatient office visits (aggressive NHL = 39%, indolent NHL = 34%). For aggressive NHL, mean monthly initial treatment phase costs (10,970 dollars) and palliative care costs (9836 dollars) were higher than costs incurred during secondary phase (3302 dollars). The mean cost of treatment failure in aggressive NHL was 14,174 dollars per month, and 85,934 dollars over the study period. The treatment of NHL was associated with substantial health care costs. Patients with aggressive lymphomas tended to accrue higher costs, compared with those with indolent lymphomas. These costs varied over time, with the highest costs occurring during the initial treatment and palliative care phases. Treatment failure was the most expensive treatment pattern. New strategies to prevent or delay treatment failure in aggressive NHL could help reduce the economic burden of NHL.

  10. Treatment failure rates and health care utilization and costs among patients with community-acquired pneumonia treated with levofloxacin or macrolides in an outpatient setting: a retrospective claims database analysis.

    PubMed

    Ye, Xin; Sikirica, Vanja; Schein, Jeffrey R; Grant, Richard; Zarotsky, Victoria; Doshi, Dilesh; Benson, Carmela Janagap; Riedel, Aylin A

    2008-02-01

    Macrolide antibiotics and fluoroquinolones are extensively used in the treatment of community-acquired pneumonia (CAP). This analysis was conducted to compare treatment failure rates and health care utilization and cost outcomes among patients with CAP treated with levo-floxacin (500 or 750 mg) or macrolides (azithromycin, clarithromycin, or erythromycin) in an outpatient setting. This was a retrospective analysis of claims data from a large US health plan. Patients were aged > or =18 years and had a primary diagnosis of CAP that was treated with oral levofloxacin or a macrolide in an outpatient setting (including physicians' offices, outpatient clinics, urgent care centers, and large ambulatory health centers). Patients were followed for 30 days after the index drug date to measure study outcomes. Multivariate regression analysis and a propensity score technique were used to compare rates of treatment failure and CAP-related health care utilization and costs. Two post hoc subgroup analyses were conducted in patients aged > or =50 and > or =65 years. Of the 7526 patients meeting the inclusion criteria, 2968 (39.4%) were treated with levofloxacin and 4558 (60.6%) with a macrolide. Unadjusted rates of treatment failure were 21.1% and 22.7% in the levofloxacin and macrolide cohorts, respectively. After adjustment for demographic characteristics, baseline comorbidities, and severity of illness, levofloxacin recipients were significantly less likely to experience treatment failure than macrolide recipients (odds ratio [OR] = 0.84; 95% CI, 0.75-0.94, P = 0.003). The likelihood of treatment failure was significantly lower in levofloxacin recipients aged > or =50 years (OR = 0.79; 95% CI, 0.66-0.94; P = 0.007) and > or =65 years (OR = 0.65; 95% CI, 0.43-1.00; P = 0.049) compared with the corresponding subgroups of macrolide recipients. The magnitude of this difference was greatest in the subgroup aged > or =65 years, which had a 35% reduced risk of treatment failure compared with the corresponding group of macrolide-treated patients. The rate of CAP-related emergency department visits was significantly lower among patients receiving levofloxa-cin (OR = 0.68; 95% CI, 0.51-0.91; P = 0.009); there were no differences in CAP-related hospitalizations or total CAP-related health care costs between levofloxa-cin and macrolide recipients. Multivariate-adjusted rates of treatment failure in outpatients with CAP were significantly lower in those treated with levofloxacin relative to those treated with a macrolide. The lower rates of treatment failure with levofloxacin were consistently observed across all patients and in the subgroups aged > or =50 and > or =65 years. Rates of emergency department visits were also significantly lower among levofloxacin-treated patients, whereas overall CAP-related hospitali-zations and costs did not differ significantly between the 2 treatment groups.

  11. An analysis of the value of spermicides in contraception.

    PubMed

    1979-11-01

    Development of the so-called modern methods of contraception has somewhat eclipsed interest in traditional methods. However, spermicides are still important for many couples and their use appears to be increasing. A brief history of the use of and research into spermicidal contraceptives is presented. The limitations of spermicides are: the necessity for use at the time of intercourse, and their high failure rate. Estimates of the failure rates of spermicides have ranged from .3 pregnancies per 100 woman-years of use to nearly 40, depending on the product used and the population tested. Just as their use depends on various social factors, so does their failure rate. Characteristics of the user deterine failure rates. Motivation is important in lowering failure rates as is education, the intracouple relationship, and previous experience with spermicides. Method failure is also caused by defects in the product, either in the active ingredient of the spermicide or in the base carrier. The main advantage of spermicidal contraception is its safety. Limited research is currently being conducted on spermicides. Areas for improvement in existing spermicides and areas for possible innovation are mentioned.

  12. Safety evaluation of driver cognitive failures and driving errors on right-turn filtering movement at signalized road intersections based on Fuzzy Cellular Automata (FCA) model.

    PubMed

    Chai, Chen; Wong, Yiik Diew; Wang, Xuesong

    2017-07-01

    This paper proposes a simulation-based approach to estimate safety impact of driver cognitive failures and driving errors. Fuzzy Logic, which involves linguistic terms and uncertainty, is incorporated with Cellular Automata model to simulate decision-making process of right-turn filtering movement at signalized intersections. Simulation experiments are conducted to estimate the relationships between cognitive failures and driving errors with safety performance. Simulation results show Different types of cognitive failures are found to have varied relationship with driving errors and safety performance. For right-turn filtering movement, cognitive failures are more likely to result in driving errors with denser conflicting traffic stream. Moreover, different driving errors are found to have different safety impacts. The study serves to provide a novel approach to linguistically assess cognitions and replicate decision-making procedures of the individual driver. Compare to crash analysis, the proposed FCA model allows quantitative estimation of particular cognitive failures, and the impact of cognitions on driving errors and safety performance. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Regression analysis of informative current status data with the additive hazards model.

    PubMed

    Zhao, Shishun; Hu, Tao; Ma, Ling; Wang, Peijie; Sun, Jianguo

    2015-04-01

    This paper discusses regression analysis of current status failure time data arising from the additive hazards model in the presence of informative censoring. Many methods have been developed for regression analysis of current status data under various regression models if the censoring is noninformative, and also there exists a large literature on parametric analysis of informative current status data in the context of tumorgenicity experiments. In this paper, a semiparametric maximum likelihood estimation procedure is presented and in the method, the copula model is employed to describe the relationship between the failure time of interest and the censoring time. Furthermore, I-splines are used to approximate the nonparametric functions involved and the asymptotic consistency and normality of the proposed estimators are established. A simulation study is conducted and indicates that the proposed approach works well for practical situations. An illustrative example is also provided.

  14. Reliability Assessment of Graphite Specimens under Multiaxial Stresses

    NASA Technical Reports Server (NTRS)

    Sookdeo, Steven; Nemeth, Noel N.; Bratton, Robert L.

    2008-01-01

    An investigation was conducted to predict the failure strength response of IG-100 nuclear grade graphite exposed to multiaxial stresses. As part of this effort, a review of failure criteria accounting for the stochastic strength response is provided. The experimental work was performed in the early 1990s at the Oak Ridge National Laboratory (ORNL) on hollow graphite tubes under the action of axial tensile loading and internal pressurization. As part of the investigation, finite-element analysis (FEA) was performed and compared with results of FEA from the original ORNL report. The new analysis generally compared well with the original analysis, although some discrepancies in the location of peak stresses was noted. The Ceramics Analysis and Reliability Evaluation of Structures Life prediction code (CARES/Life) was used with the FEA results to predict the quadrants I (tensile-tensile) and quadrant IV (compression-tension) strength response of the graphite tubes for the principle of independent action (PIA), the Weibull normal stress averaging (NSA), and the Batdorf multiaxial failure theories. The CARES/Life reliability analysis showed that all three failure theories gave similar results in quadrant I but that in quadrant IV, the PIA and Weibull normal stress-averaging theories were not conservative, whereas the Batdorf theory was able to correlate well with experimental results. The conclusion of the study was that the Batdorf theory should generally be used to predict the reliability response of graphite and brittle materials in multiaxial loading situations.

  15. The clinical course of diabetic nephropathy.

    PubMed

    Kussman, M J; Goldstein, H; Gleason, R E

    1976-10-18

    A retrospective record analysis of 112 juvenile-onset diabetics with nephropathy was conducted in order to determine their clinical course. The mean duration of diabetes at the onset of proteinuria was 17.3+/-6.0 years. Early renal failure appeared two years after the onset of protein-uria, and severe renal failure (mean serum creatinine level, 8.5+/-3.9 mg/100 ml) four years after the onset of proteinuria. The mean duration of life after the onset of severe renal failure was six months. The mortality was 53%, with 59% of the deaths attributable to renal failure and 36% to cardiovascular disease. All patients experienced progressive deterioration of renal function as well as the other complications of diabetes, the rate of progression being accelerated toward the end of the course. Juvenile onset diabetics should be considered for renal transplantation before the serum creatinine level reaches 8.5 mg/100 ml.

  16. Experiences of Patients Living With Heart Failure: A Descriptive Qualitative Study.

    PubMed

    Seah, Alvin Chuen Wei; Tan, Khoon Kiat; Huang Gan, Juvena Chew; Wang, Wenru

    2016-07-01

    The purpose of this study was to explore the experiences, needs, and coping strategies of patients living with heart failure in Singapore. A descriptive qualitative design was used. A purposive sample of 15 informants was recruited from two cardiology wards of a tertiary public hospital in Singapore. Individual face-to-face interviews were conducted with a semistructured interview guideline that was developed based on a review of the literature and a pilot study. Content analysis was adopted to analyze the data, and four main categories were identified: perceived causes, manifestations, and prognosis; enduring emotions; managing the condition; and needs from health care professionals. The informants were overwhelmed with the experience of living with heart failure due to the disruptive and uncertain nature of the condition. This study offers health care professionals practical and useful suggestions when providing holistic care for patients with heart failure. © The Author(s) 2015.

  17. The competing risks Cox model with auxiliary case covariates under weaker missing-at-random cause of failure.

    PubMed

    Nevo, Daniel; Nishihara, Reiko; Ogino, Shuji; Wang, Molin

    2017-08-04

    In the analysis of time-to-event data with multiple causes using a competing risks Cox model, often the cause of failure is unknown for some of the cases. The probability of a missing cause is typically assumed to be independent of the cause given the time of the event and covariates measured before the event occurred. In practice, however, the underlying missing-at-random assumption does not necessarily hold. Motivated by colorectal cancer molecular pathological epidemiology analysis, we develop a method to conduct valid analysis when additional auxiliary variables are available for cases only. We consider a weaker missing-at-random assumption, with missing pattern depending on the observed quantities, which include the auxiliary covariates. We use an informative likelihood approach that will yield consistent estimates even when the underlying model for missing cause of failure is misspecified. The superiority of our method over naive methods in finite samples is demonstrated by simulation study results. We illustrate the use of our method in an analysis of colorectal cancer data from the Nurses' Health Study cohort, where, apparently, the traditional missing-at-random assumption fails to hold.

  18. Task Decomposition in Human Reliability Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boring, Ronald Laurids; Joe, Jeffrey Clark

    2014-06-01

    In the probabilistic safety assessments (PSAs) used in the nuclear industry, human failure events (HFEs) are determined as a subset of hardware failures, namely those hardware failures that could be triggered by human action or inaction. This approach is top-down, starting with hardware faults and deducing human contributions to those faults. Elsewhere, more traditionally human factors driven approaches would tend to look at opportunities for human errors first in a task analysis and then identify which of those errors is risk significant. The intersection of top-down and bottom-up approaches to defining HFEs has not been carefully studied. Ideally, both approachesmore » should arrive at the same set of HFEs. This question remains central as human reliability analysis (HRA) methods are generalized to new domains like oil and gas. The HFEs used in nuclear PSAs tend to be top-down— defined as a subset of the PSA—whereas the HFEs used in petroleum quantitative risk assessments (QRAs) are more likely to be bottom-up—derived from a task analysis conducted by human factors experts. The marriage of these approaches is necessary in order to ensure that HRA methods developed for top-down HFEs are also sufficient for bottom-up applications.« less

  19. Failure analysis of an aluminum alloy material framework component induced by casting defects

    NASA Astrophysics Data System (ADS)

    Li, Bo; Hu, Weiye

    2017-09-01

    Failure analysis on a fractured radome framework component was carried out through visual observations, metallographic examination using optical microscope, fractog-raphy inspections using scanning electron microscope and chemical composition analysis. The failed frame was made of casting Al-Si7-Mg0.4 aluminum alloy. It had suffered a former vi-bration performance tests. It was indicated that the fractures were attributed to fatigue cracks which were induced by casting porosities at the outer surfaces of frame. Failure analysis was carefully conducted for the semi-penetrating crack appearing on the framework. According to the fractography inspected by scanning electron microscope, it was indicated that numerous casting porosities at the outer surface of the framework played the role of multiple fracture sources due to some applied stresses. Optical microstructure observations suggested that the dendrite-shaped casting porosities largely contributed to the crack-initiation. The groove-shaped structure at roots of spatial convex-bodies on the edge of casting porosities supplied the preferred paths of the crack-propagation. Besides, the brittle silicon eutectic particles distrib-uting along grain boundaries induced the intergranular fracture mode in the region of the over-load final fracture surface.

  20. "USA Today": Can the Nation's Newspaper Survive?

    ERIC Educational Resources Information Center

    Wicks, Robert H.

    The failure of 17 newspaper markets between 1957 and 1975 raises the question of whether the 1982 entrance of "USA Today" into the newspaper market demonstrated fiscal prudence. A 20-month advertising content analysis was conducted to assess advertising trends in "USA Today." These data were compared with industry statistics…

  1. Failure analysis on false call probe pins of microprocessor test equipment

    NASA Astrophysics Data System (ADS)

    Tang, L. W.; Ong, N. R.; Mohamad, I. S. B.; Alcain, J. B.; Retnasamy, V.

    2017-09-01

    A study has been conducted to investigate failure analysis on probe pins of test modules for microprocessor. The `health condition' of the probe pin is determined by the resistance value. A test module of 5V power supplied from Arduino UNO with "Four-wire Ohm measurement" method is implemented in this study to measure the resistance of the probe pins of a microprocessor. The probe pins from a scrapped computer motherboard is used as the test sample in this study. The functionality of the test module was validated with the pre-measurement experiment via VEE Pro software. Lastly, the experimental work have demonstrated that the implemented test module have the capability to identify the probe pin's `health condition' based on the measured resistance value.

  2. Magellan/Galileo solder joint failure analysis and recommendations

    NASA Technical Reports Server (NTRS)

    Ross, Ronald G., Jr.

    1989-01-01

    On or about November 10, 1988 an open circuit solder joint was discovered in the Magellan Radar digital unit (DFU) during integration testing at Kennedy Space Center (KSC). A detailed analysis of the cause of the failure was conducted at the Jet Propulsion Laboratory leading to the successful repair of many pieces of affected electronic hardware on both the Magellan and Galileo spacecraft. The problem was caused by the presence of high thermal coefficient of expansion heat sink and conformal coating materials located in the large (0.055 inch) gap between Dual Inline Packages (DIPS) and the printed wiring board. The details of the observed problems are described and recommendations are made for improved design and testing activities in the future.

  3. Using Combined SFTA and SFMECA Techniques for Space Critical Software

    NASA Astrophysics Data System (ADS)

    Nicodemos, F. G.; Lahoz, C. H. N.; Abdala, M. A. D.; Saotome, O.

    2012-01-01

    This work addresses the combined Software Fault Tree Analysis (SFTA) and Software Failure Modes, Effects and Criticality Analysis (SFMECA) techniques applied to space critical software of satellite launch vehicles. The combined approach is under research as part of the Verification and Validation (V&V) efforts to increase software dependability and as future application in other projects under development at Instituto de Aeronáutica e Espaço (IAE). The applicability of such approach was conducted on system software specification and applied to a case study based on the Brazilian Satellite Launcher (VLS). The main goal is to identify possible failure causes and obtain compensating provisions that lead to inclusion of new functional and non-functional system software requirements.

  4. Diagnostics of psychophysiological states and motivation in elite athletes.

    PubMed

    Korobeynikov, G; Mazmanian, K; Korobeynikova, L; Jagiello, W

    2011-01-01

    Concepts explored in our study concerned identification of various types of motivation and their connection to psychophysiological states in elite judo and Greco-Roman wrestlers. We tried to figure out how do these different types of motivation interact to describe psychophysiological state in qualified wrestlers. Neuropsychological evaluation methods as simple (SRT) and choice reaction-time (CRT) tests, HRV measurements, psychological questionnaires. To explore obtained data methods of statistical analysis were used Obtained data show that different combinations of levels of motivation to achieve success and motivation to avoid failure provoke different psychophysiological states. Conducted experiment revealed that combination of high levels of both motivation to achievement of success and motivation to avoid failure provides better psychophysiological state in elite wrestlers compared to other groups with different combinations of motivational variables. Conducted experiment revealed that motivation to avoid failures had been formed as a personality formation, which compensates excessive tension, caused by high level of motivation to achieve and regulate the psychophysiological state. This can be viewed as an effect of training in athletes (Tab. 3, Fig. 1, Ref. 38).

  5. A Cross-Cultural Comparison of Symptom Reporting and Symptom Clusters in Heart Failure.

    PubMed

    Park, Jumin; Johantgen, Mary E

    2017-07-01

    An understanding of symptoms in heart failure (HF) among different cultural groups has become increasingly important. The purpose of this study was to compare symptom reporting and symptom clusters in HF patients between a Western (the United States) and an Eastern Asian sample (China and Taiwan). A secondary analysis of a cross-sectional observational study was conducted. The data were obtained from a matched HF patient sample from the United States and China/Taiwan ( N = 240 in each). Eight selective items related to HF symptoms from the Minnesota Living with Heart Failure Questionnaire were analyzed. Compared with the U.S. sample, HF patients from China/Taiwan reported a lower level of symptom distress. Analysis of two different regional groups did not result in the same number of clusters using latent class approach: the United States (four classes) and China/Taiwan (three classes). The study demonstrated that symptom reporting and identification of symptom clusters might be influenced by cultural factors.

  6. Noninvasive positive pressure ventilation for acute respiratory failure in delirious patients: understudied, underreported, or underappreciated? A systematic review and meta-analysis.

    PubMed

    Charlesworth, Michael; Elliott, Mark W; Holmes, John D

    2012-12-01

    We performed a systematic review and meta-analysis of the literature to determine the prevalence of delirium in patients receiving noninvasive positive pressure ventilation (NPPV) for acute respiratory failure and to quantify the prognostic impact of delirium with respect to NPPV failure. We searched the databases EMBASE (1996 to present), MEDLINE (1996 to present), PsycINFO(®) (2002 to present) and CINAHL (1992 to present). A Google™ search and hand searching of bibliographies or relevant articles were also performed. We searched for prospective observational studies conducted in a setting where patients with acute respiratory failure receiving NPPV were screened for delirium. All authors independently assessed references for inclusion and extracted data. Information was collated regarding study design, baseline characteristics of included patients, and the prevalence of delirium. Where prognostic information regarding NPPV failure was reported, a risk ratio for the association between delirium and NPPV failure was derived. These values were pooled in the meta-analysis. Three articles were retrieved by the search strategy. These included 239 patients receiving noninvasive ventilation who were assessed for delirium. The prevalence of delirium was recorded at between 33 and 38 % with a pooled prevalence of 37 %. Two studies reported prognostic data and the risk ratios for noninvasive ventilation failure in delirium were calculated as 1.79 (95 % CI 1.09-2.94) and 3.28 (95 % CI 1.60-6.73). A meta-analysis was performed and the pooled risk ratio was found to be 2.12 (95 % CI 1.41-3.18). The data in this context was scarce and of low quality. A diagnosis of delirium was made in 9 patients and inferred in 80. Despite the current lack of high-quality data and studies, the high reported prevalence of delirium and the association with noninvasive ventilation failure lends support for more awareness amongst health-care professionals and more routine screening. More focused primary research is necessary in this area. Adherence to NICE guidelines regarding delirium in these patients should be a standard of care.

  7. A structured analysis of in vitro failure loads and failure modes of fiber, metal, and ceramic post-and-core systems.

    PubMed

    Fokkinga, Wietske A; Kreulen, Cees M; Vallittu, Pekka K; Creugers, Nico H J

    2004-01-01

    This study sought to aggregate literature data on in vitro failure loads and failure modes of prefabricated fiber-reinforced composite (FRC) post systems and to compare them to those of prefabricated metal, custom-cast, and ceramic post systems. The literature was searched using MEDLINE from 1984 to 2003 for dental articles in English. Keywords used were (post or core or buildup or dowel) and (teeth or tooth). Additional inclusion/exclusion steps were conducted, each step by two independent readers: (1) Abstracts describing post-and-core techniques to reconstruct endodontically treated teeth and their mechanical and physical characteristics were included (descriptive studies or reviews were excluded); (2) articles that included FRC post systems were selected; (3) in vitro studies, single-rooted human teeth, prefabricated FRC posts, and composite as the core material were the selection criteria; and (4) failure loads and modes were extracted from the selected papers, and failure modes were dichotomized (distinction was made between "favorable failures," defined as reparable failures, and "unfavorable failures,"defined as irreparable [root] fractures). The literature search revealed 1,984 abstracts. Included were 244, 42, and 12 articles in the first, second, and third selection steps, respectively. Custom-cast post systems showed higher failure loads than prefabricated FRC post systems, whereas ceramic showed lower failure loads. Significantly more favorable failures occurred with prefabricated FRC post systems than with prefabricated and custom-cast metal post systems. The variable "post system" had a significant effect on mean failure loads. FRC post systems more frequently showed favorable failure modes than did metal post systems.

  8. Verification of the Multi-Axial, Temperature and Time Dependent (MATT) Failure Criterion

    NASA Technical Reports Server (NTRS)

    Richardson, David E.; Macon, David J.

    2005-01-01

    An extensive test and analytical effort has been completed by the Space Shuttle's Reusable Solid Rocket Motor (KSKM) nozzle program to characterize the failure behavior of two epoxy adhesives (TIGA 321 and EA946). As part of this effort, a general failure model, the "Multi-Axial, Temperature, and Time Dependent" or MATT failure criterion was developed. In the initial development of this failure criterion, tests were conducted to provide validation of the theory under a wide range of test conditions. The purpose of this paper is to present additional verification of the MATT failure criterion, under new loading conditions for the adhesives TIGA 321 and EA946. In many cases, the loading conditions involve an extrapolation from the conditions under which the material models were originally developed. Testing was conducted using three loading conditions: multi-axial tension, torsional shear, and non-uniform tension in a bondline condition. Tests were conducted at constant and cyclic loading rates ranging over four orders of magnitude. Tests were conducted under environmental conditions of primary interest to the RSRM program. The temperature range was not extreme, but the loading ranges were extreme (varying by four orders of magnitude). It should be noted that the testing was conducted at temperatures below the glass transition temperature of the TIGA 321 adhesive. However for the EA946, the testing was conducted at temperatures that bracketed the glass transition temperature.

  9. Micromechanics Based Failure Analysis of Heterogeneous Materials

    NASA Astrophysics Data System (ADS)

    Sertse, Hamsasew M.

    In recent decades, heterogeneous materials are extensively used in various industries such as aerospace, defense, automotive and others due to their desirable specific properties and excellent capability of accumulating damage. Despite their wide use, there are numerous challenges associated with the application of these materials. One of the main challenges is lack of accurate tools to predict the initiation, progression and final failure of these materials under various thermomechanical loading conditions. Although failure is usually treated at the macro and meso-scale level, the initiation and growth of failure is a complex phenomena across multiple scales. The objective of this work is to enable the mechanics of structure genome (MSG) and its companion code SwiftComp to analyze the initial failure (also called static failure), progressive failure, and fatigue failure of heterogeneous materials using micromechanics approach. The initial failure is evaluated at each numerical integration point using pointwise and nonlocal approach for each constituent of the heterogeneous materials. The effects of imperfect interfaces among constituents of heterogeneous materials are also investigated using a linear traction-displacement model. Moreover, the progressive and fatigue damage analyses are conducted using continuum damage mechanics (CDM) approach. The various failure criteria are also applied at a material point to analyze progressive damage in each constituent. The constitutive equation of a damaged material is formulated based on a consistent irreversible thermodynamics approach. The overall tangent modulus of uncoupled elastoplastic damage for negligible back stress effect is derived. The initiation of plasticity and damage in each constituent is evaluated at each numerical integration point using a nonlocal approach. The accumulated plastic strain and anisotropic damage evolution variables are iteratively solved using an incremental algorithm. The damage analyses are performed for both brittle failure/high cycle fatigue (HCF) for negligible plastic strain and ductile failure/low cycle fatigue (LCF) for large plastic strain. The proposed approach is incorporated in SwiftComp and used to predict the initial failure envelope, stress-strain curve for various loading conditions, and fatigue life of heterogeneous materials. The combined effects of strain hardening and progressive fatigue damage on the effective properties of heterogeneous materials are also studied. The capability of the current approach is validated using several representative examples of heterogeneous materials including binary composites, continuous fiber-reinforced composites, particle-reinforced composites, discontinuous fiber-reinforced composites, and woven composites. The predictions of MSG are also compared with the predictions obtained using various micromechanics approaches such as Generalized Methods of Cells (GMC), Mori-Tanaka (MT), and Double Inclusions (DI) and Representative Volume Element (RVE) Analysis (called as 3-dimensional finite element analysis (3D FEA) in this document). This study demonstrates that a micromechanics based failure analysis has a great potential to rigorously and more accurately analyze initiation and progression of damage in heterogeneous materials. However, this approach requires material properties specific to damage analysis, which are needed to be independently calibrated for each constituent.

  10. Enhancement of the fatigue performance of Ti-6Al-4V implant products

    NASA Astrophysics Data System (ADS)

    Wimalasiri, Dematapaksha H. R. J.

    Implants surgery, in particular hip implants, is fast becoming a routine, popular approach for curing diseases such as, osteoarthritis and rheumatic arthritis. However one potential problem with the insertion of a metal implant is that of the risk of fatigue failure. Numerous factors affect the propensity of a metal to fatigue, none more so than the physical and stress state of the surface. This research is focused on an assessment of the role of manufacturing processes on the fatigue performance of hip implants made from a Ti-6Al-4V alloy. The role of surface defects, surface residual stresses and material microstructural properties which influence fatigue performance were examined. Characterization of the implant material and of the processes involved in actual hip implant manufacturing were conducted. Rotating bend fatigue testing using hour glass shaped specimens was conducted to evaluate the fatigue performance at selected manufacturing stages. The surface roughness/defects and residual stresses were measured prior to conducting fatigue tests. A variation of fatigue limit, attributed to variations of surface roughness and surface residual stress was observed. The influence of parameters such as, stress ratio and mean stress effect, variation of fracture mechanics parameters (e.g. DeltaK[th]) and the limiting threshold conditions for different stages of cracks were investigated in the context of Kitagawa-Takahashi (K-T) type diagrams. Experimental data was used to develop models which were used to calculate, (i). fatigue life at respective stress amplitude and, (ii). the fatigue limit of components with known surface roughness/defect size and residual stress. To evaluate material crack growth properties a surface replication method was used. The output from both models showed good correlation with experimental data. Comprehensive fractography was conducted using optical, secondary electron, and infinite focus microscopy to support the results obtained from fatigue testing. Analysis was performed on in-vivo hip implant failure data covering the last 12 years. Fatigue failures occur in two locations on the implant stem, namely the cone area and the neck area. These two locations were investigated separately to identify the factors, such as; the category of implant most vulnerable to failure, service life, design features, fixation with the host bone, crack initiation features and propagation details. An attempt was made to compare in-vivo fatigue features with experimental fatigue results. X-ray diffraction (XRD) was used to investigate the surface residual stresses resulting from different manufacturing processes. The results were confirmed and software and hardware settings were calibrated in accordance with the results obtained from XRD analysis conducted at National Physical Laboratories (NPL), UK. Surface roughness measurements were also conducted using stylus type surface profilometer. The knowledge gained from this research can be used to understand the causes and modes of in-vivo fatigue failure of hip implants made of Ti-6Al-4V. Understanding the fatigue/mechanical properties of the implant material enables recommendations and optimization of good practice in manufacturing to eliminate in-vivo fatigue failures.

  11. Tapered Roller Bearing Damage Detection Using Decision Fusion Analysis

    NASA Technical Reports Server (NTRS)

    Dempsey, Paula J.; Kreider, Gary; Fichter, Thomas

    2006-01-01

    A diagnostic tool was developed for detecting fatigue damage of tapered roller bearings. Tapered roller bearings are used in helicopter transmissions and have potential for use in high bypass advanced gas turbine aircraft engines. A diagnostic tool was developed and evaluated experimentally by collecting oil debris data from failure progression tests conducted using health monitoring hardware. Failure progression tests were performed with tapered roller bearings under simulated engine load conditions. Tests were performed on one healthy bearing and three pre-damaged bearings. During each test, data from an on-line, in-line, inductance type oil debris sensor and three accelerometers were monitored and recorded for the occurrence of bearing failure. The bearing was removed and inspected periodically for damage progression throughout testing. Using data fusion techniques, two different monitoring technologies, oil debris analysis and vibration, were integrated into a health monitoring system for detecting bearing surface fatigue pitting damage. The data fusion diagnostic tool was evaluated during bearing failure progression tests under simulated engine load conditions. This integrated system showed improved detection of fatigue damage and health assessment of the tapered roller bearings as compared to using individual health monitoring technologies.

  12. Failure Analysis of Short-Circuited Lithium-Ion Battery with Nickel-Manganese-Cobalt/Graphite Electrode.

    PubMed

    Lee, Seung-Mi; Kim, Jea-Yeon; Byeon, Jai-Won

    2018-09-01

    Accidental failures and explosions of lithium-ion batteries have been reported in recent years. To determine the root causes and mechanisms of these failures from the perspective of material degradation, failure analysis was conducted for an intentionally shorted lithium-ion battery. The battery was subjected to electrical overcharging and mechanical pressing to simulate internal short-circuiting. After in situ measurement of the temperature increase during the short-circuiting of the electrodes, the disassembled battery components (i.e., the anode, cathode, and separator) were analyzed by scanning electron microscopy and energy-dispersive X-ray spectroscopy. Regardless of the simulated short-circuit method (mechanical or electrical), damage was observed in the shorted batteries. Numerous small cracks and chemical reaction products were observed on the electrode surface, along with pore shielding on the separator. The event of short-circuiting increased the surface temperature of the battery to approximately 90 °C, which prompted the deterioration and decomposition of the electrolyte, thus affecting the overall battery performance; this was attributed to the decomposition of the lithium salt at 60 °C. The gas generation due to the breakdown of the electrolyte causes pressure accumulation inside the cell; therefore, the electrolyte leaks.

  13. Fidelity Failures in Brief Strategic Family Therapy for Adolescent Drug Abuse: A Clinical Analysis.

    PubMed

    Lebensohn-Chialvo, Florencia; Rohrbaugh, Michael J; Hasler, Brant P

    2018-04-30

    As evidence-based family treatments for adolescent substance use and conduct problems gain traction, cutting edge research moves beyond randomized efficacy trials to address questions such as how these treatments work and how best to disseminate them to community settings. A key factor in effective dissemination is treatment fidelity, which refers to implementing an intervention in a manner consistent with an established manual. While most fidelity research is quantitative, this study offers a qualitative clinical analysis of fidelity failures in a large, multisite effectiveness trial of Brief Strategic Family Therapy (BSFT) for adolescent drug abuse, where BSFT developers trained community therapists to administer this intervention in their own agencies. Using case notes and video recordings of therapy sessions, an independent expert panel first rated 103 cases on quantitative fidelity scales grounded in the BSFT manual and the broader structural-strategic framework that informs BSFT intervention. Because fidelity was generally low, the panel reviewed all cases qualitatively to identify emergent types or categories of fidelity failure. Ten categories of failures emerged, characterized by therapist omissions (e.g., failure to engage key family members, failure to think in threes) and commissions (e.g., off-model, nonsystemic formulations/interventions). Of these, "failure to think in threes" appeared basic and particularly problematic, reflecting the central place of this idea in structural theory and therapy. Although subject to possible bias, our observations highlight likely stumbling blocks in exporting a complex family treatment like BSFT to community settings. These findings also underscore the importance of treatment fidelity in family therapy research. © 2018 Family Process Institute.

  14. Effect of exercise on diastolic function in heart failure patients: a systematic review and meta-analysis.

    PubMed

    Pearson, M J; Mungovan, S F; Smart, N A

    2017-03-01

    Diastolic dysfunction contributes to the development and progression of heart failure. Conventional echocardiography and tissue Doppler imaging are widely utilised in clinical research providing a number of indices of diastolic function valuable in the diagnosis and prognosis of heart failure patients. The aim of this meta-analysis was to quantify the effect of exercise training on diastolic function in patients with heart failure. Exercise training studies that investigate different indices of diastolic function in patients with heart failure have reported that exercise training improves diastolic function in these patients. We sought to add to the current literature by quantifying, where possible, the effect of exercise training on diastolic function. We conducted database searches (PubMed, EBSCO, EMBASE, and Cochrane Trials Register to 31 July 2016) for exercise based rehabilitation trials in heart failure, using the search terms 'exercise training, diastolic function and diastolic dysfunction'. Data from six studies, with a total of 266 heart failure with reduced ejection fraction (HFrEF) participants, 144 in intervention groups and 122 in control groups, indicated a significant reduction in the ratio of early diastolic transmitral velocity (E) to early diastolic tissue velocity (E') (E/E' ratio) with exercise training, exercise vs. control mean difference (MD) of -2.85 (95% CI -3.66 to -2.04, p < 0.00001). Data from five studies in heart failure with preserved ejection fraction (HFpEF) patients, with a total of 204 participants, 115 in intervention groups and 89 in control groups, also demonstrated a significant improvement in E/E' in exercise vs. control MD of -2.38 (95% CI -3.47 to -1.28, p < 0.0001).

  15. Proactive risk assessment of blood transfusion process, in pediatric emergency, using the Health Care Failure Mode and Effects Analysis (HFMEA).

    PubMed

    Dehnavieh, Reza; Ebrahimipour, Hossein; Molavi-Taleghani, Yasamin; Vafaee-Najar, Ali; Noori Hekmat, Somayeh; Esmailzdeh, Hamid

    2014-12-25

    Pediatric emergency has been considered as a high risk area, and blood transfusion is known as a unique clinical measure, therefore this study was conducted with the purpose of assessing the proactive risk assessment of blood transfusion process in Pediatric Emergency of Qaem education- treatment center in Mashhad, by the Healthcare Failure Mode and Effects Analysis (HFMEA) methodology. This cross-sectional study analyzed the failure mode and effects of blood transfusion process by a mixture of quantitative-qualitative method. The proactive HFMEA was used to identify and analyze the potential failures of the process. The information of the items in HFMEA forms was collected after obtaining a consensus of experts' panel views via the interview and focus group discussion sessions. The Number of 77 failure modes were identified for 24 sub-processes enlisted in 8 processes of blood transfusion. Totally 13 failure modes were identified as non-acceptable risk (a hazard score above 8) in the blood transfusion process and were transferred to the decision tree. Root causes of high risk modes were discussed in cause-effect meetings and were classified based on the UK national health system (NHS) approved classifications model. Action types were classified in the form of acceptance (11.6%), control (74.2%) and elimination (14.2%). Recommendations were placed in 7 categories using TRIZ ("Theory of Inventive Problem Solving.") The re-engineering process for the required changes, standardizing and updating the blood transfusion procedure, root cause analysis of blood transfusion catastrophic events, patient identification bracelet, training classes and educational pamphlets for raising awareness of personnel, and monthly gathering of transfusion medicine committee have all been considered as executive strategies in work agenda in pediatric emergency.

  16. Proactive Risk Assessment of Blood Transfusion Process, in Pediatric Emergency, Using the Health Care Failure Mode and Effects Analysis (HFMEA)

    PubMed Central

    Dehnavieh, Reza; Ebrahimipour, Hossein; Molavi-Taleghani, Yasamin; Vafaee-Najar, Ali; Hekmat, Somayeh Noori; Esmailzdeh, Hamid

    2015-01-01

    Introduction: Pediatric emergency has been considered as a high risk area, and blood transfusion is known as a unique clinical measure, therefore this study was conducted with the purpose of assessing the proactive risk assessment of blood transfusion process in Pediatric Emergency of Qaem education- treatment center in Mashhad, by the Healthcare Failure Mode and Effects Analysis (HFMEA) methodology. Methodology: This cross-sectional study analyzed the failure mode and effects of blood transfusion process by a mixture of quantitative-qualitative method. The proactive HFMEA was used to identify and analyze the potential failures of the process. The information of the items in HFMEA forms was collected after obtaining a consensus of experts’ panel views via the interview and focus group discussion sessions. Results: The Number of 77 failure modes were identified for 24 sub-processes enlisted in 8 processes of blood transfusion. Totally 13 failure modes were identified as non-acceptable risk (a hazard score above 8) in the blood transfusion process and were transferred to the decision tree. Root causes of high risk modes were discussed in cause-effect meetings and were classified based on the UK national health system (NHS) approved classifications model. Action types were classified in the form of acceptance (11.6%), control (74.2%) and elimination (14.2%). Recommendations were placed in 7 categories using TRIZ (“Theory of Inventive Problem Solving.”) Conclusion: The re-engineering process for the required changes, standardizing and updating the blood transfusion procedure, root cause analysis of blood transfusion catastrophic events, patient identification bracelet, training classes and educational pamphlets for raising awareness of personnel, and monthly gathering of transfusion medicine committee have all been considered as executive strategies in work agenda in pediatric emergency. PMID:25560332

  17. Comprehensive, Quantitative Risk Assessment of CO{sub 2} Geologic Sequestration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lepinski, James

    2013-09-30

    A Quantitative Failure Modes and Effects Analysis (QFMEA) was developed to conduct comprehensive, quantitative risk assessments on CO{sub 2} capture, transportation, and sequestration or use in deep saline aquifers, enhanced oil recovery operations, or enhanced coal bed methane operations. The model identifies and characterizes potential risks; identifies the likely failure modes, causes, effects and methods of detection; lists possible risk prevention and risk mitigation steps; estimates potential damage recovery costs, mitigation costs and costs savings resulting from mitigation; and ranks (prioritizes) risks according to the probability of failure, the severity of failure, the difficulty of early failure detection and themore » potential for fatalities. The QFMEA model generates the necessary information needed for effective project risk management. Diverse project information can be integrated into a concise, common format that allows comprehensive, quantitative analysis, by a cross-functional team of experts, to determine: What can possibly go wrong? How much will damage recovery cost? How can it be prevented or mitigated? What is the cost savings or benefit of prevention or mitigation? Which risks should be given highest priority for resolution? The QFMEA model can be tailored to specific projects and is applicable to new projects as well as mature projects. The model can be revised and updated as new information comes available. It accepts input from multiple sources, such as literature searches, site characterization, field data, computer simulations, analogues, process influence diagrams, probability density functions, financial analysis models, cost factors, and heuristic best practices manuals, and converts the information into a standardized format in an Excel spreadsheet. Process influence diagrams, geologic models, financial models, cost factors and an insurance schedule were developed to support the QFMEA model. Comprehensive, quantitative risk assessments were conducted on three (3) sites using the QFMEA model: (1) SACROC Northern Platform CO{sub 2}-EOR Site in the Permian Basin, Scurry County, TX, (2) Pump Canyon CO{sub 2}-ECBM Site in the San Juan Basin, San Juan County, NM, and (3) Farnsworth Unit CO{sub 2}-EOR Site in the Anadarko Basin, Ochiltree County, TX. The sites were sufficiently different from each other to test the robustness of the QFMEA model.« less

  18. Control system failure monitoring using generalized parity relations. M.S. Thesis Interim Technical Report

    NASA Technical Reports Server (NTRS)

    Vanschalkwyk, Christiaan Mauritz

    1991-01-01

    Many applications require that a control system must be tolerant to the failure of its components. This is especially true for large space-based systems that must work unattended and with long periods between maintenance. Fault tolerance can be obtained by detecting the failure of the control system component, determining which component has failed, and reconfiguring the system so that the failed component is isolated from the controller. Component failure detection experiments that were conducted on an experimental space structure, the NASA Langley Mini-Mast are presented. Two methodologies for failure detection and isolation (FDI) exist that do not require the specification of failure modes and are applicable to both actuators and sensors. These methods are known as the Failure Detection Filter and the method of Generalized Parity Relations. The latter method was applied to three different sensor types on the Mini-Mast. Failures were simulated in input-output data that were recorded during operation of the Mini-Mast. Both single and double sensor parity relations were tested and the effect of several design parameters on the performance of these relations is discussed. The detection of actuator failures is also treated. It is shown that in all the cases it is possible to identify the parity relations directly from input-output data. Frequency domain analysis is used to explain the behavior of the parity relations.

  19. Design of Rock Slope Reinforcement: An Himalayan Case Study

    NASA Astrophysics Data System (ADS)

    Tiwari, Gaurav; Latha, Gali Madhavi

    2016-06-01

    The stability analysis of the two abutment slopes of a railway bridge proposed at about 359 m above the ground level, crossing a river and connecting two hill faces in the Himalayas, India, is presented. The bridge is located in a zone of high seismic activity. The rock slopes are composed of a heavily jointed rock mass and the spacing, dip and dip direction of joint sets are varying at different locations. Geological mapping was carried out to characterize all discontinuities present along the slopes. Laboratory and field investigations were conducted to assess the geotechnical properties of the intact rock, rock mass and joint infill. Stability analyses of these rock slopes were carried out using numerical programmes. Loads from the foundations resting on the slopes and seismic accelerations estimated from site-specific ground response analysis were considered. The proposed slope profile with several berms between successive foundations was simulated in the numerical model. An equivalent continuum approach with Hoek and Brown failure criterion was initially used in a finite element model to assess the global stability of the slope abutments. In the second stage, finite element analysis of rock slopes with all joint sets with their orientations, spacing and properties explicitly incorporated into the numerical model was taken up using continuum with joints approach. It was observed that the continuum with joints approach was able to capture the local failures in some of the slope sections, which were verified using wedge failure analysis and stereographic projections. Based on the slope deformations and failure patterns observed from the numerical analyses, rock anchors were designed to achieve the target factors of safety against failure while keeping the deformations within the permissible limits. Detailed design of rock anchors and comparison of the stability of slopes with and without reinforcement are presented.

  20. Current trends and outcomes of breast reconstruction following nipple-sparing mastectomy: results from a national multicentric registry with 1006 cases over a 6-year period.

    PubMed

    Casella, Donato; Calabrese, Claudio; Orzalesi, Lorenzo; Gaggelli, Ilaria; Cecconi, Lorenzo; Santi, Caterina; Murgo, Roberto; Rinaldi, Stefano; Regolo, Lea; Amanti, Claudio; Roncella, Manuela; Serra, Margherita; Meneghini, Graziano; Bortolini, Massimiliano; Altomare, Vittorio; Cabula, Carlo; Catalano, Francesca; Cirilli, Alfredo; Caruso, Francesco; Lazzaretti, Maria Grazia; Meattini, Icro; Livi, Lorenzo; Cataliotti, Luigi; Bernini, Marco

    2017-05-01

    Reconstruction options following nipple-sparing mastectomy (NSM) are diverse and not yet investigated with level IA evidence. The analysis of surgical and oncological outcomes of NSM from the Italian National Registry shows its safety and wide acceptance both for prophylactic and therapeutic cases. A further in-depth analysis of the reconstructive approaches with their trend over time and their failures is the aim of this study. Data extraction from the National Database was performed restricting cases to the 2009-2014 period. Different reconstruction procedures were analyzed in terms of their distribution over time and with respect to specific indications. A 1-year minimum follow-up was conducted to assess reconstructive unsuccessful events. Univariate and multivariate analyses were performed to investigate the causes of both prosthetic and autologous failures. 913 patients, for a total of 1006 procedures, are included in the analysis. A prosthetic only reconstruction is accomplished in 92.2 % of cases, while pure autologous tissues are employed in 4.2 % and a hybrid (prosthetic plus autologous) in 3.6 %. Direct-to-implant (DTI) reaches 48.7 % of all reconstructions in the year 2014. Prophylactic NSMs have a DTI reconstruction in 35.6 % of cases and an autologous tissue flap in 12.9 % of cases. Failures are 2.7 % overall: 0 % in pure autologous flaps and 9.1 % in hybrid cases. Significant risk factors for failures are diabetes and the previous radiation therapy on the operated breast. Reconstruction following NSM is mostly prosthetic in Italy, with DTI gaining large acceptance over time. Failures are low and occurring in diabetic and irradiated patients at the multivariate analysis.

  1. Failure mode and effects analysis: a comparison of two common risk prioritisation methods.

    PubMed

    McElroy, Lisa M; Khorzad, Rebeca; Nannicelli, Anna P; Brown, Alexandra R; Ladner, Daniela P; Holl, Jane L

    2016-05-01

    Failure mode and effects analysis (FMEA) is a method of risk assessment increasingly used in healthcare over the past decade. The traditional method, however, can require substantial time and training resources. The goal of this study is to compare a simplified scoring method with the traditional scoring method to determine the degree of congruence in identifying high-risk failures. An FMEA of the operating room (OR) to intensive care unit (ICU) handoff was conducted. Failures were scored and ranked using both the traditional risk priority number (RPN) and criticality-based method, and a simplified method, which designates failures as 'high', 'medium' or 'low' risk. The degree of congruence was determined by first identifying those failures determined to be critical by the traditional method (RPN≥300), and then calculating the per cent congruence with those failures designated critical by the simplified methods (high risk). In total, 79 process failures among 37 individual steps in the OR to ICU handoff process were identified. The traditional method yielded Criticality Indices (CIs) ranging from 18 to 72 and RPNs ranging from 80 to 504. The simplified method ranked 11 failures as 'low risk', 30 as medium risk and 22 as high risk. The traditional method yielded 24 failures with an RPN ≥300, of which 22 were identified as high risk by the simplified method (92% agreement). The top 20% of CI (≥60) included 12 failures, of which six were designated as high risk by the simplified method (50% agreement). These results suggest that the simplified method of scoring and ranking failures identified by an FMEA can be a useful tool for healthcare organisations with limited access to FMEA expertise. However, the simplified method does not result in the same degree of discrimination in the ranking of failures offered by the traditional method. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  2. An Analysis of Initial Global Citizenship in a Liberal Arts College in Northeastern Pennsylvania

    ERIC Educational Resources Information Center

    Anthony, Dorothy; Miller, Patricia Bederman; Yarrish, Karen K.

    2014-01-01

    There are an increasing number of organizations conducting business in the global environment (Hill, 2011). Expatriate employees are frequently used and are critical for success in these assignments (Carpenter, Sanders, & Gregersen, 2000). Adjusting to a foreign culture is one reason for high failure rates of expatriates (Garonzik, Brockner…

  3. Development of the Main Wing Structure of a High Altitude Long Endurance UAV

    NASA Astrophysics Data System (ADS)

    Park, Sang Wook; Shin, Jeong Woo; Kim, Tae-Uk

    2018-04-01

    To enhance the flight endurance of a HALE UAV, the main wing of the UAV should have a high aspect ratio and low structural weight. Since a main wing constructed with the thin walled and slender components needed for low structural weight can suffer catastrophic failure during flight, it is important to develop a light-weight airframe without sacrificing structural integrity. In this paper, the design of the main wing of the HALE UAV was conducted using spars which were composed of a carbon-epoxy cylindrical tube and bulkheads to achieve both the weight reduction and structural integrity. The spars were sized using numerical analysis considering non-linear deformation under bending moment. Static strength testing of the wing was conducted under the most critical load condition. Then, the experimental results obtained for the wing were compared to the analytical result from the non-linear finite-element analysis. It was found that the developed main wing reduced its structural weight without any failure under the ultimate load condition of the static strength testing.

  4. Strain-controlled fatigue of acrylic bone cement.

    PubMed

    Carter, D R; Gates, E I; Harris, W H

    1982-09-01

    Monotonic tensile tests and tension-compression fatigue tests were conducted of wet acrylic bone cement specimens at 37 degrees C. All testing was conducted in strain control at a strain rate of 0.02/s. Weibull analysis of the tensile tests indicated that monotonic fracture was governed more strongly by strain than stress. The number of cycles to fatigue failure was also more strongly controlled by strain amplitude than stress amplitude. Specimen porosity distribution played a major role in determining the tensile and fatigue strengths. The degree of data scatter suggests that Weibull analysis of fatigue data may be useful in developing design criteria for the surgical use of bone cement.

  5. The Effect of Positive Group Psychotherapy and Motivational Interviewing on Smoking Cessation: A Qualitative Descriptive Study.

    PubMed

    Lee, Eun Jin

    The purpose of this study was to describe the process and evaluate the effect of positive group psychotherapy and motivational interviewing as an intervention for smoking cessation. A qualitative descriptive study was conducted at a university in South Korea. Positive group psychotherapy and motivational interviewing were attended by 36 smokers for 1 hour once a week, for 6 hours. A recorded exit interview was conducted after the intervention. The resulting transcripts were analyzed with content analysis and thematic analysis. Among the 36 study participants, the importance of stopping smoking was rated higher in the successful cessation (defined as those who ceased smoking for at least 3 months; hereafter, success group) group (8.6 ± 0.4, n = 10) than in the failed cessation (defined as those who did not cease smoking for at least 3 months; hereafter, failure group) group (7.75 ± 0.3, n = 26; p < .01). The confidence to stop smoking was rated higher by the successes (8.4 ± 0.3) than by the failures (5.5 ± 0.4; p < .01). More successes wanted to stop smoking for the sake of their loved ones (60%) and health (50%), whereas more failures wanted to stop smoking for saving money (45.5%). Failures had more cross-addiction than successes (three to four addictions: 31.5% vs. 20%). When participants were asked to find 10 personality merits, 78% of the successes and 47% of the failures found their 10 merits. The therapeutic process was described as "sharing the smoking cessation process with others," "detailed guidance for stress management and smoking cessation," and "compliments about efforts for smoking cessation." The importance of and confidence in smoking cessation were predictors for successful cessation for 3-6 months. Motivational interviewing increased motivations, whereas positive group psychotherapy increased positive thoughts and confidence.

  6. MO-D-213-02: Quality Improvement Through a Failure Mode and Effects Analysis of Pediatric External Beam Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gray, J; Lukose, R; Bronson, J

    2015-06-15

    Purpose: To conduct a failure mode and effects analysis (FMEA) as per AAPM Task Group 100 on clinical processes associated with teletherapy, and the development of mitigations for processes with identified high risk. Methods: A FMEA was conducted on clinical processes relating to teletherapy treatment plan development and delivery. Nine major processes were identified for analysis. These steps included CT simulation, data transfer, image registration and segmentation, treatment planning, plan approval and preparation, and initial and subsequent treatments. Process tree mapping was utilized to identify the steps contained within each process. Failure modes (FM) were identified and evaluated with amore » scale of 1–10 based upon three metrics: the severity of the effect, the probability of occurrence, and the detectability of the cause. The analyzed metrics were scored as follows: severity – no harm = 1, lethal = 10; probability – not likely = 1, certainty = 10; detectability – always detected = 1, undetectable = 10. The three metrics were combined multiplicatively to determine the risk priority number (RPN) which defined the overall score for each FM and the order in which process modifications should be deployed. Results: Eighty-nine procedural steps were identified with 186 FM accompanied by 193 failure effects with 213 potential causes. Eighty-one of the FM were scored with a RPN > 10, and mitigations were developed for FM with RPN values exceeding ten. The initial treatment had the most FM (16) requiring mitigation development followed closely by treatment planning, segmentation, and plan preparation with fourteen each. The maximum RPN was 400 and involved target delineation. Conclusion: The FMEA process proved extremely useful in identifying previously unforeseen risks. New methods were developed and implemented for risk mitigation and error prevention. Similar to findings reported for adult patients, the process leading to the initial treatment has an associated high risk.« less

  7. Experimental micromechanical approach to failure process in CFRP cross-ply laminates

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Takeda, N.; Ogihara, S.; Kobayashi, A.

    The microscopic failure process of three different types of cross-ply laminates, (0/90{sub n}/0) (n = 4, 8, 12), was investigated at R.T. and 80 C. Progressive damage parameters, the transverse crack density and the delamination ratio, were measured. A simple modified shear-lag analysis including the thermal residual strains was conducted to predict the transverse crack density as a function of laminate strain, considering the constraint effect, as well as the strength distribution of the transverse layer. The analysis was also extended to the system containing delamination to predict the delamination length. A prediction was also presented for the transverse crackmore » density including the effect of the delamination growth. The prediction showed good agreement with the experimental results.« less

  8. 40 CFR 141.211 - Special notice for repeated failure to conduct monitoring of the source water for Cryptosporidium...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 23 2014-07-01 2014-07-01 false Special notice for repeated failure to conduct monitoring of the source water for Cryptosporidium and for failure to determine bin classification or mean Cryptosporidium level. 141.211 Section 141.211 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS ...

  9. Impact of a massive earthquake on adherence to antiretroviral therapy, mental health, and treatment failure among people living with HIV in Nepal

    PubMed Central

    Nakazawa, Minato; Kotaki, Tomohiro; Bastola, Anup; Kameoka, Masanori

    2018-01-01

    Introduction The April 2015 Nepal earthquake resulted in more than 8,700 deaths and 22,000 casualties including damage to health facilities. The impact of this situation on chronic conditions such as human immunodeficiency virus infection and acquired immune deficiency syndrome (HIV/AIDS) may become a long-lasting public health threat. Therefore, the objectives of this study were i) to assess the association of antiretroviral therapy (ART) adherence with mental health problems, and social behaviors, ii) to examine factors affecting treatment failure, and iii) to investigate changes in ART adherence and post-traumatic stress disorder (PTSD) among people living with HIV 6 and 12 months after the disaster. Methods Study was conducted 6 months after the earthquake in 2015 with a sample size of 305 earthquake victims with HIV and followed after 12 months of the earthquake. A logistic regression analysis was used to examine relationships, while a paired t-test analysis was conducted to assess changes in adherence to ART and PTSD level at 6 months and 12 months after earthquake. Results In the earthquake, 5.2% of the participants lost their family member. Approximately 44% of participants had earthquake-PTSD symptoms and 50% experienced HIV stigma. PTSD and HIV status disclosure were significantly associated with adherence to ART, while HIV stigma and religion were associated with treatment failure. PTSD and adherence levels to ART were significantly improved over the 6-month period. Conclusion Awareness programs for general public to eliminate HIV stigma; promote psychosocial counseling to earthquake victims living with HIV in order to reduce PTSD will contribute to maintaining optimal ART adherence and to prevent treatment failure. PMID:29889840

  10. Meso-modeling of Carbon Fiber Composite for Crash Safety Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin, Shih-Po; Chen, Yijung; Zeng, Danielle

    2017-04-06

    In the conventional approach, the material properties for crash safety simulations are typically obtained from standard coupon tests, where the test results only provide single layer material properties used in crash simulations. However, the lay-up effects for the failure behaviors of the real structure were not considered in numerical simulations. Hence, there was discrepancy between the crash simulations and experimental tests. Consequently, an intermediate stage is required for accurate predictions. Some component tests are required to correlate the material models in the intermediate stage. In this paper, a Mazda Tube under high-impact velocity is chosen as an example for themore » crash safety analysis. The tube consists of 24 layers of uni-directional (UD) carbon fiber composite materials, in which 4 layers are perpendicular to, while the other layers are parallel to the impact direction. An LS-DYNA meso-model was constructed with orthotropic material models counting for the single-layer material behaviors. Between layers, a node-based tie-break contact was used for modeling the delamination of the composite material. Since fiber directions are not single-oriented, the lay-up effects could be an important effect. From the first numerical trial, premature material failure occurred due to the use of material parameters obtained directly from the coupon tests. Some parametric studies were conducted to identify the cause of the numerical instability. The finding is that the material failure strength used in the numerical model needs to be enlarged to stabilize the numerical model. Some hypothesis was made to provide the foundation for enlarging the failure strength and the corresponding experiments will be conducted to validate the hypothesis.« less

  11. Notes from the field: malnutrition and mortality--southern Somalia, July 2011.

    PubMed

    2011-08-05

    In July 2011, the internationally supported Food Security and Nutrition Analysis Unit-Somalia conducted nutrition and mortality surveys across 17 livelihood zones in southern Somalia to assess the impact of 18 months of insecurity and drought, which have resulted in crop failure, livestock mortality, increased cereal prices, and widespread malnutrition. On July 14, CDC was asked to assist with analyzing the survey data. This report describes the results of that analysis.

  12. Degradation analysis of anode-supported intermediate temperature-solid oxide fuel cells under various failure modes

    NASA Astrophysics Data System (ADS)

    Lee, Tae-Hee; Park, Ka-Young; Kim, Ji-Tae; Seo, Yongho; Kim, Ki Buem; Song, Sun-Ju; Park, Byoungnam; Park, Jun-Young

    2015-02-01

    This study focuses on mechanisms and symptoms of several simulated failure modes, which may have significant influences on the long-term durability and operational stability of intermediate temperature-solid oxide fuel cells (IT-SOFCs), including fuel/oxidation starvation by breakdown of fuel/air supply components and wet and dry cycling atmospheres. Anode-supported IT-SOFCs consisting of a Ba0.5Sr0.5Co0.8Fe0.2O3-δ (BSCF)-Nd0.1Ce0.9O2-δ (NDC) composite cathode with an NDC electrolyte on a Ni-NDC anode substrate are fabricated via dry-pressings followed by the co-firing method. Comprehensive and systematic research based on the failure mode and effect analysis (FMEA) of anode-supported IT-SOFCs is conducted using various electrochemical and physiochemical analysis techniques to extend our understanding of the major mechanisms of performance deterioration under SOFC operating conditions. The fuel-starvation condition in the fuel-pump failure mode causes irreversible mechanical degradation of the electrolyte and cathode interface by the dimensional expansion of the anode support due to the oxidation of Ni metal to NiO. In contrast, the BSCF cathode shows poor stability under wet and dry cycling modes of cathode air due to the strong electroactivity of SrO with H2O. On the other hand, the air-depletion phenomena under air-pump failure mode results in the recovery of cell performance during the long-term operation without the visible microstructural transformation through the reduction of anode overvoltage.

  13. Interesting insights into instability of slopes and rock fall in the morphodynamic Himalayan terrane

    NASA Astrophysics Data System (ADS)

    Singh, T. N.; Vishal, V.; Pradhan, S. P.

    2015-12-01

    Himalayan mountain ranges are tectonically and seismically very active and experience many disastrous events with time due to slope failure. Frequent failures of rock cut slopes cause obstruction in traffic and often lead to fatalities. In recent years, the number of tragedies has increased when associated with regional phenomena such at the Kedarnath tragedy of 2013 and the Gorkha earthquake of 2015. The influence of such phenomena on the stability of slopes along important national highways and key settlement areas only raise the risk to lives and property. We conducted a multi-approach investigation for some key slopes along the National Highway 58 in Uttarakhand Himalaya, India. A very detailed field work was conducted to identify the unstable slopes and those with some history of failure. The pertinent geomechanical characteristics of the representative rock samples were determined in the laboratory. Based on the structural data, kinematic analysis was carried out. Finally the slopes were simulated using FDM based simulator, Flac/Slope for analysing the health of the slopes and Rockfall 4.0 to investigate the phenomenon of rockfall along the Highway. It was found that few slopes were weak due to the inherent weak rock materials while few slopes made up of high strength rocks were effectively weak due to prone-to-failure orientation of the joints. Quantification of bounce-height of rock blocks during fall, their energy, velocity and displacement along the slope was also done. Using 3-D simulations, few critically-stable slopes that appear to be stable, were identified. Little ground movement could be capable of triggering a large scale failure in the area. Slopes in the studied region are under threat to failure and need immediate proper planning using the suggested remedial measures.

  14. The dynamic failure behavior of tungsten heavy alloys subjected to transverse loads

    NASA Astrophysics Data System (ADS)

    Tarcza, Kenneth Robert

    Tungsten heavy alloys (WHA), a category of particulate composites used in defense applications as kinetic energy penetrators, have been studied for many years. Even so, their dynamic failure behavior is not fully understood and cannot be predicted by numerical models presently in use. In this experimental investigation, a comprehensive understanding of the high-rate transverse-loading fracture behavior of WHA has been developed. Dynamic fracture events spanning a range of strain rates and loading conditions were created via mechanical testing and used to determine the influence of surface condition and microstructure on damage initiation, accumulation, and sample failure under different loading conditions. Using standard scanning electron microscopy metallographic and fractographic techniques, sample surface condition is shown to be extremely influential to the manner in which WHA fails, causing a fundamental change from externally to internally nucleated failures as surface condition is improved. Surface condition is characterized using electron microscopy and surface profilometry. Fracture surface analysis is conducted using electron microscopy, and linear elastic fracture mechanics is used to understand the influence of surface condition, specifically initial flaw size, on sample failure behavior. Loading conditions leading to failure are deduced from numerical modeling and experimental observation. The results highlight parameters and considerations critical to the understanding of dynamic WHA fracture and the development of dynamic WHA failure models.

  15. Risky Business: condom failures as experienced by female sex workers in Mombasa, Kenya.

    PubMed

    Bradburn, Caitlyn K; Wanje, George; Pfeiffer, James; Jaoko, Walter; Kurth, Ann E; McClelland, R Scott

    2017-03-01

    Limited research exists about condom failure as experienced by female sex workers. We conducted a qualitative study to examine how female sex workers in Mombasa, Kenya contextualise and explain the occurrence of condom failure. In-depth, semi-structured interviews were conducted with thirty female sex workers to ascertain their condom failure experiences. We qualitatively analysed interview transcripts to determine how the women mitigate risk and cope with condom failure. Condom failure was not uncommon, but women mitigated the risk by learning about correct use, and by supplying and applying condoms themselves. Many female sex workers felt that men intentionally rupture condoms. Few women were aware of or felt empowered to prevent HIV, STIs, and pregnancy after condom failure. Interventions to equip female sex workers with strategies for minimising the risk of HIV, STIs, and pregnancy in the aftermath of a condom failure should be investigated.

  16. The use of failure mode and effect analysis in a radiation oncology setting: the Cancer Treatment Centers of America experience.

    PubMed

    Denny, Diane S; Allen, Debra K; Worthington, Nicole; Gupta, Digant

    2014-01-01

    Delivering radiation therapy in an oncology setting is a high-risk process where system failures are more likely to occur because of increasing utilization, complexity, and sophistication of the equipment and related processes. Healthcare failure mode and effect analysis (FMEA) is a method used to proactively detect risks to the patient in a particular healthcare process and correct potential errors before adverse events occur. FMEA is a systematic, multidisciplinary team-based approach to error prevention and enhancing patient safety. We describe our experience of using FMEA as a prospective risk-management technique in radiation oncology at a national network of oncology hospitals in the United States, capitalizing not only on the use of a team-based tool but also creating momentum across a network of collaborative facilities seeking to learn from and share best practices with each other. The major steps of our analysis across 4 sites and collectively were: choosing the process and subprocesses to be studied, assembling a multidisciplinary team at each site responsible for conducting the hazard analysis, and developing and implementing actions related to our findings. We identified 5 areas of performance improvement for which risk-reducing actions were successfully implemented across our enterprise. © 2012 National Association for Healthcare Quality.

  17. Ephaptic coupling rescues conduction failure in weakly coupled cardiac tissue with voltage-gated gap junctions

    NASA Astrophysics Data System (ADS)

    Weinberg, S. H.

    2017-09-01

    Electrical conduction in cardiac tissue is usually considered to be primarily facilitated by gap junctions, providing a pathway between the intracellular spaces of neighboring cells. However, recent studies have highlighted the role of coupling via extracellular electric fields, also known as ephaptic coupling, particularly in the setting of reduced gap junction expression. Further, in the setting of reduced gap junctional coupling, voltage-dependent gating of gap junctions, an oft-neglected biophysical property in computational studies, produces a positive feedback that promotes conduction failure. We hypothesized that ephaptic coupling can break the positive feedback loop and rescue conduction failure in weakly coupled cardiac tissue. In a computational tissue model incorporating voltage-gated gap junctions and ephaptic coupling, we demonstrate that ephaptic coupling can rescue conduction failure in weakly coupled tissue. Further, ephaptic coupling increased conduction velocity in weakly coupled tissue, and importantly, reduced the minimum gap junctional coupling necessary for conduction, most prominently at fast pacing rates. Finally, we find that, although neglecting gap junction voltage-gating results in negligible differences in well coupled tissue, more significant differences occur in weakly coupled tissue, greatly underestimating the minimal gap junctional coupling that can maintain conduction. Our study suggests that ephaptic coupling plays a conduction-preserving role, particularly at rapid heart rates.

  18. Experimental and theoretical investigation of fatigue life in reusable rocket thrust chambers

    NASA Technical Reports Server (NTRS)

    Hannum, N. P.; Kasper, H. J.; Pavli, A. J.

    1976-01-01

    During a test program to investigate low-cycle thermal fatigue, 13 rocket combustion chambers were fabricated and cyclically test fired to failure. Six oxygen-free, high-conductivity (OFHC) copper and seven Amzirc chambers were tested. The chamber liners were fabricated of copper or copper alloy and contained milled coolant channels. The chambers were completed by means of an electroformed nickel closeout. The oxidant/fuel ratio for the liquid oxygen and gaseous hydrogen propellants was 6.0. The failures in the OFHC copper chambers were not typical fatigue failures but are described as creep rupture enhanced by ratcheting. The coolant channels bulged toward the chamber centerline, resulting in progressive thinning of the wall during each cycle. The failures in the Amzirc alloy chambers were caused by low-cycle thermal fatigue. The lives were much shorter than were predicted by an analytical structural analysis computer program used in conjunction with fatigue life data from isothermal test specimens, due to the uneven distribution of Zr in the chamber material.

  19. Voltage Fluctuation in a Supercapacitor During a High-g Impact

    PubMed Central

    Dai, Keren; Wang, Xiaofeng; Yin, Yajiang; Hao, Chenglong; You, Zheng

    2016-01-01

    Supercapacitors (SCs) are a type of energy storage device with high power density and long lifecycles. They have widespread applications, such as powering electric vehicles and micro scale devices. Working stability is one of the most important properties of SCs, and it is of significant importance to investigate the operational characteristics of SCs working under extreme conditions, particularly during high-g acceleration. In this paper, the failure mechanism of SCs upon high-g impact is thoroughly studied. Through an analysis of the intrinsic reaction mechanism during the high-g impact, a multi-faceted physics model is established. Additionally, a multi-field coupled kinetics simulation of the SC failure during a high-g impact is presented. Experimental tests are conducted that confirm the validity of the proposed model. The key factors of failure, such as discharge currents and discharging levels, are analyzed and discussed. Finally, a possible design is proposed to avoid the failure of SCs upon high-g impact. PMID:27958309

  20. Electric propulsion reliability: Statistical analysis of on-orbit anomalies and comparative analysis of electric versus chemical propulsion failure rates

    NASA Astrophysics Data System (ADS)

    Saleh, Joseph Homer; Geng, Fan; Ku, Michelle; Walker, Mitchell L. R.

    2017-10-01

    With a few hundred spacecraft launched to date with electric propulsion (EP), it is possible to conduct an epidemiological study of EP's on orbit reliability. The first objective of the present work was to undertake such a study and analyze EP's track record of on orbit anomalies and failures by different covariates. The second objective was to provide a comparative analysis of EP's failure rates with those of chemical propulsion. Satellite operators, manufacturers, and insurers will make reliability- and risk-informed decisions regarding the adoption and promotion of EP on board spacecraft. This work provides evidence-based support for such decisions. After a thorough data collection, 162 EP-equipped satellites launched between January 1997 and December 2015 were included in our dataset for analysis. Several statistical analyses were conducted, at the aggregate level and then with the data stratified by severity of the anomaly, by orbit type, and by EP technology. Mean Time To Anomaly (MTTA) and the distribution of the time to (minor/major) anomaly were investigated, as well as anomaly rates. The important findings in this work include the following: (1) Post-2005, EP's reliability has outperformed that of chemical propulsion; (2) Hall thrusters have robustly outperformed chemical propulsion, and they maintain a small but shrinking reliability advantage over gridded ion engines. Other results were also provided, for example the differentials in MTTA of minor and major anomalies for gridded ion engines and Hall thrusters. It was shown that: (3) Hall thrusters exhibit minor anomalies very early on orbit, which might be indicative of infant anomalies, and thus would benefit from better ground testing and acceptance procedures; (4) Strong evidence exists that EP anomalies (onset and likelihood) and orbit type are dependent, a dependence likely mediated by either the space environment or differences in thrusters duty cycles; (5) Gridded ion thrusters exhibit both infant and wear-out failures, and thus would benefit from a reliability growth program that addresses both these types of problems.

  1. Investigating premature pavement failure due to moisture : final report.

    DOT National Transportation Integrated Search

    2009-07-01

    This report details the forensic investigations conducted to identify the causes of pavement failures shortly after a rehabilitation activity on five interstate highway projects in Oregon, and the research efforts conducted to develop guidelines to m...

  2. Orbiter post-tire failure and skid testing results

    NASA Technical Reports Server (NTRS)

    Daugherty, Robert H.; Stubbs, Sandy M.

    1989-01-01

    An investigation was conducted at the NASA Langley Research Center's Aircraft Landing Dynamics Facility (ALDF) to define the post-tire failure drag characteristics of the Space Shuttle Orbiter main tire and wheel assembly. Skid tests on various materials were also conducted to define their friction and wear rate characteristics under higher speed and bearing pressures than any previous tests. The skid tests were conducted to support a feasibility study of adding a skid to the orbiter strut between the main tires to protect an intact tire from failure due to overload should one of the tires fail. Roll-on-rim tests were conducted to define the ability of a standard and a modified orbiter main wheel to roll without a tire. Results of the investigation are combined into a generic model of strut drag versus time under failure conditions for inclusion into rollout simulators used to train the shuttle astronauts.

  3. Effects of Gas Pressure on the Failure Characteristics of Coal

    NASA Astrophysics Data System (ADS)

    Xie, Guangxiang; Yin, Zhiqiang; Wang, Lei; Hu, Zuxiang; Zhu, Chuanqi

    2017-07-01

    Several experiments were conducted using self-developed equipment for visual gas-solid coupling mechanics. The raw coal specimens were stored in a container filled with gas (99% CH4) under different initial gas pressure conditions (0.0, 0.5, 1.0, and 1.5 MPa) for 24 h prior to testing. Then, the specimens were tested in a rock-testing machine, and the mechanical properties, surface deformation and failure modes were recorded using strain gauges, an acoustic emission (AE) system and a camera. An analysis of the fractals of fragments and dissipated energy was performed to understand the changes observed in the stress-strain and crack propagation behaviour of the gas-containing coal specimens. The results demonstrate that increased gas pressure leads to a reduction in the uniaxial compression strength (UCS) of gas-containing coal and the critical dilatancy stress. The AE, surface deformation and fractal analysis results show that the failure mode changes during the gas state. Interestingly, a higher initial gas pressure will cause the damaged cracks and failure of the gas-containing coal samples to become severe. The dissipated energy characteristic in the failure process of a gas-containing coal sample is analysed using a combination of fractal theory and energy principles. Using the theory of fracture mechanics, based on theoretical analyses and calculations, the stress intensity factor of crack tips increases as the gas pressure increases, which is the main cause of the reduction in the UCS and critical dilatancy stress and explains the influence of gas in coal failure. More serious failure is created in gas-containing coal under a high gas pressure and low exterior load.

  4. Echinocandins Compared to Fluconazole for Candidemia of a Urinary Tract Source: A Propensity Score Analysis.

    PubMed

    Cuervo, Guillermo; Garcia-Vidal, Carolina; Puig-Asensio, Mireia; Vena, Antonio; Meije, Yolanda; Fernández-Ruiz, Mario; González-Barberá, Eva; Blanco-Vidal, María José; Manzur, Adriana; Cardozo, Celia; Gudiol, Carlota; Montejo, José Miguel; Pemán, Javier; Ayats, Josefina; Aguado, Jose María; Muñoz, Patricia; Marco, Francesc; Almirante, Benito; Carratalà, Jordi

    2017-05-15

    Whether echinocandins could be used to treat candidemia of a urinary tract source (CUTS) is unknown. We aimed to provide current epidemiological information of CUTS and to compare echinocandin to fluconazole treatment on CUTS outcomes. A multicenter study of adult patients with candidemia was conducted in 9 hospitals. CUTS was defined as a candidemia with concomitant candiduria by the same organism associated with significant urological comorbidity. The primary outcome assessed was clinical failure (defined by 7-day mortality or persistent candidemia) in patients treated with either an echinocandin or fluconazole. A propensity score was calculated and then entered into a regression model. Of 2176 episodes of candidemia, 128 were CUTS (5.88%). Most CUTS cases were caused by Candida albicans (52.7%), followed by Candida glabrata (25.6%) and Candida tropicalis (16.3%). Clinical failure occurred in 7 patients (20%) treated with an echinocandin and in 15 (17.1%) treated with fluconazole (P = .730). Acute renal failure (adjusted odds ratio [AOR], 3.01; 95% confidence interval [CI], 1.01-8.91; P = .047) was the only independent factor associated with clinical failure, whereas early urinary tract drainage procedures (surgical, percutaneous, or endoscopic) were identified as protective (AOR, 0.08; 95% CI, .02-.31; P < .001). Neither univariate nor multivariate analysis showed that echinocandin therapy altered the risk of clinical failure. Initial echinocandin therapy was not associated with clinical failure in patients with CUTS. Notably, acute renal failure predicted worse outcomes and performing an early urologic procedure was a protective measure. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail: journals.permissions@oup.com

  5. Review of nutritional screening and assessment tools and clinical outcomes in heart failure.

    PubMed

    Lin, Hong; Zhang, Haifeng; Lin, Zheng; Li, Xinli; Kong, Xiangqin; Sun, Gouzhen

    2016-09-01

    Recent studies have suggested that undernutrition as defined using multidimensional nutritional evaluation tools may affect clinical outcomes in heart failure (HF). The evidence supporting this correlation is unclear. Therefore, we conducted this systematic review to critically appraise the use of multidimensional evaluation tools in the prediction of clinical outcomes in HF. We performed descriptive analyses of all identified articles involving qualitative analyses. We used STATA to conduct meta-analyses when at least three studies that tested the same type of nutritional assessment or screening tools and used the same outcome were identified. Sensitivity analyses were conducted to validate our positive results. We identified 17 articles with qualitative analyses and 11 with quantitative analysis after comprehensive literature searching and screening. We determined that the prevalence of malnutrition is high in HF (range 16-90 %), particularly in advanced and acute decompensated HF (approximate range 75-90 %). Undernutrition as identified by multidimensional evaluation tools may be significantly associated with hospitalization, length of stay and complications and is particularly strongly associated with high mortality. The meta-analysis revealed that compared with other tools, Mini Nutritional Assessment (MNA) scores were the strongest predictors of mortality in HF [HR (4.32, 95 % CI 2.30-8.11)]. Our results remained reliable after conducting sensitivity analyses. The prevalence of malnutrition is high in HF, particularly in advanced and acute decompensated HF. Moreover, undernutrition as identified by multidimensional evaluation tools is significantly associated with unfavourable prognoses and high mortality in HF.

  6. The Joule heating problem in silver nanowire transparent electrodes

    NASA Astrophysics Data System (ADS)

    Khaligh, H. H.; Xu, L.; Khosropour, A.; Madeira, A.; Romano, M.; Pradére, C.; Tréguer-Delapierre, M.; Servant, L.; Pope, M. A.; Goldthorpe, I. A.

    2017-10-01

    Silver nanowire transparent electrodes have shown considerable potential to replace conventional transparent conductive materials. However, in this report we show that Joule heating is a unique and serious problem with these electrodes. When conducting current densities encountered in organic solar cells, the average surface temperature of indium tin oxide (ITO) and silver nanowire electrodes, both with sheet resistances of 60 ohms/square, remains below 35 °C. However, in contrast to ITO, the temperature in the nanowire electrode is very non-uniform, with some localized points reaching temperatures above 250 °C. These hotspots accelerate nanowire degradation, leading to electrode failure after 5 days of continuous current flow. We show that graphene, a commonly used passivation layer for these electrodes, slows nanowire degradation and creates a more uniform surface temperature under current flow. However, the graphene does not prevent Joule heating in the nanowires and local points of high temperature ultimately shift the failure mechanism from nanowire degradation to melting of the underlying plastic substrate. In this paper, surface temperature mapping, lifetime testing under current flow, post-mortem analysis, and modelling illuminate the behaviour and failure mechanisms of nanowires under extended current flow and provide guidelines for managing Joule heating.

  7. Investigating accidents involving aircraft manufactured from polymer composite materials

    NASA Astrophysics Data System (ADS)

    Dunn, Leigh

    This study looks into the examination of polymer composite wreckage from the perspective of the aircraft accident investigator. It develops an understanding of the process of wreckage examination as well as identifying the potential for visual and macroscopic interpretation of polymer composite aircraft wreckage. The in-field examination of aircraft wreckage, and subsequent interpretations of material failures, can be a significant part of an aircraft accident investigation. As the use of composite materials in aircraft construction increases, the understanding of how macroscopic failure characteristics of composite materials may aid the field investigator is becoming of increasing importance.. The first phase of this research project was to explore how investigation practitioners conduct wreckage examinations. Four accident investigation case studies were examined. The analysis of the case studies provided a framework of the wreckage examination process. Subsequently, a literature survey was conducted to establish the current level of knowledge on the visual and macroscopic interpretation of polymer composite failures. Relevant literature was identified and a compendium of visual and macroscopic characteristics was created. Two full-scale polymer composite wing structures were loaded statically, in an upward bending direction, until each wing structure fractured and separated. The wing structures were subsequently examined for the existence of failure characteristics. The examination revealed that whilst characteristics were present, the fragmentation of the structure destroyed valuable evidence. A hypothetical accident scenario utilising the fractured wing structures was developed, which UK government accident investigators subsequently investigated. This provided refinement to the investigative framework and suggested further guidance on the interpretation of polymer composite failures by accident investigators..

  8. 'I think my body has become addicted to those tablets'. Chronic heart failure patients' understanding of and beliefs about their illness and its treatment: A qualitative longitudinal study from Uganda.

    PubMed

    Namukwaya, Elizabeth; Murray, Scott A; Downing, Julia; Leng, Mhoira; Grant, Liz

    2017-01-01

    Patients with heart failure in Uganda present for health care with advanced structural heart disease, have repeated hospitalizations and poorly controlled disease symptoms. The reasons for these are unclear. Literature from other settings shows that patients' understanding of their illness and their beliefs influence their health related behaviour. The study aimed to explore the beliefs of patients with heart failure, their understanding of their illness and its treatment, and how this influenced their health related behaviour to inform future health education programs, information and palliative care services. Serial qualitative in-depth interviews were conducted with Heart Failure patients who were purposively sampled and recruited in Mulago National Referral Hospital until thematic saturation was reached. In-depth interviews were conducted at three time points over the course of their illness with intervals of 3 months between interviews. A grounded theory approach was used in data analysis. The University of Edinburgh ethics committee, Mulago Hospital Research Ethics committee and the Uganda National Council of Science and Technology (Reference numbers D/GC/178; MREC 33, SS 3083 respectively) approved the research. A total of 40 face to face qualitative longitudinal interviews (36-patient alone, 4 paired-patient and family carer), were conducted with 21 patients. The findings revealed that heart failure patients were unaware of the symptoms of the illness and their definition of illness differed from that of health professionals. Patients understood their diagnosis, cause of illness, prognosis and the importance of the medicines differently from health professionals, and had insufficient information on self-care. Lay beliefs were used to explain many aspects of the illness and treatments. All these influenced where patients sought care and their adherence to treatment, self-care and follow up leading to uncontrolled disease. There is a high level of health illiteracy among heart failure patients in Uganda. Patients rely on lay beliefs to make health decisions and medical information is often miscomprehended. There is an urgent need for health education using culturally appropriate information.

  9. ‘I think my body has become addicted to those tablets’. Chronic heart failure patients’ understanding of and beliefs about their illness and its treatment: A qualitative longitudinal study from Uganda

    PubMed Central

    Murray, Scott A.; Downing, Julia; Leng, Mhoira; Grant, Liz

    2017-01-01

    Background Patients with heart failure in Uganda present for health care with advanced structural heart disease, have repeated hospitalizations and poorly controlled disease symptoms. The reasons for these are unclear. Literature from other settings shows that patients’ understanding of their illness and their beliefs influence their health related behaviour. The study aimed to explore the beliefs of patients with heart failure, their understanding of their illness and its treatment, and how this influenced their health related behaviour to inform future health education programs, information and palliative care services. Methods Serial qualitative in-depth interviews were conducted with Heart Failure patients who were purposively sampled and recruited in Mulago National Referral Hospital until thematic saturation was reached. In-depth interviews were conducted at three time points over the course of their illness with intervals of 3 months between interviews. A grounded theory approach was used in data analysis. The University of Edinburgh ethics committee, Mulago Hospital Research Ethics committee and the Uganda National Council of Science and Technology (Reference numbers D/GC/178; MREC 33, SS 3083 respectively) approved the research. Results A total of 40 face to face qualitative longitudinal interviews (36-patient alone, 4 paired-patient and family carer), were conducted with 21 patients. The findings revealed that heart failure patients were unaware of the symptoms of the illness and their definition of illness differed from that of health professionals. Patients understood their diagnosis, cause of illness, prognosis and the importance of the medicines differently from health professionals, and had insufficient information on self-care. Lay beliefs were used to explain many aspects of the illness and treatments. All these influenced where patients sought care and their adherence to treatment, self-care and follow up leading to uncontrolled disease. Conclusion There is a high level of health illiteracy among heart failure patients in Uganda. Patients rely on lay beliefs to make health decisions and medical information is often miscomprehended. There is an urgent need for health education using culturally appropriate information. PMID:28957338

  10. Metallic wear debris sensors: promising developments in failure prevention for wind turbine gearsets and similar components

    NASA Astrophysics Data System (ADS)

    Poley, Jack; Dines, Michael

    2011-04-01

    Wind turbines are frequently located in remote, hard-to-reach locations, making it difficult to apply traditional oil analysis sampling of the machine's critical gearset at timely intervals. Metal detection sensors are excellent candidates for sensors designed to monitor machine condition in vivo. Remotely sited components, such as wind turbines, therefore, can be comfortably monitored from a distance. Online sensor technology has come of age with products now capable of identifying onset of wear in time to avoid or mitigate failure. Online oil analysis is now viable, and can be integrated with onsite testing to vet sensor alarms, as well as traditional oil analysis, as furnished by offsite laboratories. Controlled laboratory research data were gathered from tests conducted on a typical wind turbine gearbox, wherein total ferrous particle measurement and metallic particle counting were employed and monitored. The results were then compared with a physical inspection for wear experienced by the gearset. The efficacy of results discussed herein strongly suggests the viability of metallic wear debris sensors in today's wind turbine gearsets, as correlation between sensor data and machine trauma were very good. By extension, similar components and settings would also seem amenable to wear particle sensor monitoring. To our knowledge no experiments such as described herein, have previously been conducted and published.

  11. The Influence of Various Factors on High School Football Helmet Face Mask Removal: A Retrospective, Cross-Sectional Analysis

    PubMed Central

    Swartz, Erik E; Decoster, Laura C; Norkus, Susan A; Cappaert, Thomas A

    2007-01-01

    Context: Most research on face mask removal has been performed on unused equipment. Objective: To identify and compare factors that influence the condition of helmet components and their relationship to face mask removal. Design: A cross-sectional, retrospective study. Setting: Five athletic equipment reconditioning/recertification facilities. Participants: 2584 helmets from 46 high school football teams representing 5 geographic regions. Intervention(s): Helmet characteristics (brand, model, hardware components) were recorded. Helmets were mounted and face mask removal was attempted using a cordless screwdriver. The 2004 season profiles and weather histories were obtained for each high school. Main Outcome Measure(s): Success and failure (including reason) for removal of 4 screws from the face mask were noted. Failure rates among regions, teams, reconditioning year, and screw color (type) were compared. Weather histories were compared. We conducted a discriminant analysis to determine if weather variables, region, helmet brand and model, reconditioning year, and screw color could predict successful face mask removal. Metallurgic analysis of screw samples was performed. Results: All screws were successfully removed from 2165 (84%) helmets. At least 1 screw could not be removed from 419 (16%) helmets. Significant differences were found for mean screw failure per helmet among the 5 regions, with the Midwest having the lowest failure rate (0.08 ± 0.38) and the Southern (0.33 ± 0.72), the highest. Differences were found in screw failure rates among the 46 teams (F1,45 = 9.4, P < .01). Helmets with the longest interval since last reconditioning (3 years) had the highest failure rate, 0.47 ± 0.93. Differences in success rates were found among 4 screw types (χ21,4 = 647, P < .01), with silver screws having the lowest percentage of failures (3.4%). A discriminant analysis (Λ = .932, χ214,n=2584 = 175.34, P < .001) revealed screw type to be the strongest predictor of successful removal. Conclusions: Helmets with stainless steel or nickel-plated carbon steel screws reconditioned in the previous year had the most favorable combination of factors for successful screw removal. T-nut spinning at the side screw locations was the most common reason and location for failure. PMID:17597938

  12. Reliability Assessment for Low-cost Unmanned Aerial Vehicles

    NASA Astrophysics Data System (ADS)

    Freeman, Paul Michael

    Existing low-cost unmanned aerospace systems are unreliable, and engineers must blend reliability analysis with fault-tolerant control in novel ways. This dissertation introduces the University of Minnesota unmanned aerial vehicle flight research platform, a comprehensive simulation and flight test facility for reliability and fault-tolerance research. An industry-standard reliability assessment technique, the failure modes and effects analysis, is performed for an unmanned aircraft. Particular attention is afforded to the control surface and servo-actuation subsystem. Maintaining effector health is essential for safe flight; failures may lead to loss of control incidents. Failure likelihood, severity, and risk are qualitatively assessed for several effector failure modes. Design changes are recommended to improve aircraft reliability based on this analysis. Most notably, the control surfaces are split, providing independent actuation and dual-redundancy. The simulation models for control surface aerodynamic effects are updated to reflect the split surfaces using a first-principles geometric analysis. The failure modes and effects analysis is extended by using a high-fidelity nonlinear aircraft simulation. A trim state discovery is performed to identify the achievable steady, wings-level flight envelope of the healthy and damaged vehicle. Tolerance of elevator actuator failures is studied using familiar tools from linear systems analysis. This analysis reveals significant inherent performance limitations for candidate adaptive/reconfigurable control algorithms used for the vehicle. Moreover, it demonstrates how these tools can be applied in a design feedback loop to make safety-critical unmanned systems more reliable. Control surface impairments that do occur must be quickly and accurately detected. This dissertation also considers fault detection and identification for an unmanned aerial vehicle using model-based and model-free approaches and applies those algorithms to experimental faulted and unfaulted flight test data. Flight tests are conducted with actuator faults that affect the plant input and sensor faults that affect the vehicle state measurements. A model-based detection strategy is designed and uses robust linear filtering methods to reject exogenous disturbances, e.g. wind, while providing robustness to model variation. A data-driven algorithm is developed to operate exclusively on raw flight test data without physical model knowledge. The fault detection and identification performance of these complementary but different methods is compared. Together, enhanced reliability assessment and multi-pronged fault detection and identification techniques can help to bring about the next generation of reliable low-cost unmanned aircraft.

  13. Strength and failure analysis of composite-to-composite adhesive bonds with different surface treatments

    NASA Astrophysics Data System (ADS)

    Paranjpe, Nikhil; Alamir, Mohammed; Alonayni, Abdullah; Asmatulu, Eylem; Rahman, Muhammad M.; Asmatulu, Ramazan

    2018-03-01

    Adhesives are widely utilized materials in aviation, automotive, energy, defense, and marine industries. Adhesive joints are gradually supplanting mechanical fasteners because they are lightweight structures, thus making the assembly lighter and easier. They also act as a sealant to prevent a structural joint from galvanic corrosion and leakages. Adhesive bonds provide high joint strength because of the fact that the load is distributed uniformly on the joint surface, while in mechanical joints, the load is concentrated at one point, thus leading to stress at that point and in turn causing joint failures. This research concentrated on the analysis of bond strength and failure loads in adhesive joint of composite-to-composite surfaces. Different durations of plasma along with the detergent cleaning were conducted on the composite surfaces prior to the adhesive applications and curing processes. The joint strength of the composites increased about 34% when the surface was plasma treated for 12 minutes. It is concluded that the combination of different surface preparations, rather than only one type of surface treatment, provides an ideal joint quality for the composites.

  14. Frequency and clinical predictors of coronary artery disease in chronic renal failure renal transplant candidates.

    PubMed

    de Albuquerque Seixas, Emerson; Carmello, Beatriz Leone; Kojima, Christiane Akemi; Contti, Mariana Moraes; Modeli de Andrade, Luiz Gustavo; Maiello, José Roberto; Almeida, Fernando Antonio; Martin, Luis Cuadrado

    2015-05-01

    Cardiovascular diseases are major causes of mortality in chronic renal failure patients before and after renal transplantation. Among them, coronary disease presents a particular risk; however, risk predictors have been used to diagnose coronary heart disease. This study evaluated the frequency and importance of clinical predictors of coronary artery disease in chronic renal failure patients undergoing dialysis who were renal transplant candidates, and assessed a previously developed scoring system. Coronary angiographies conducted between March 2008 and April 2013 from 99 candidates for renal transplantation from two transplant centers in São Paulo state were analyzed for associations between significant coronary artery diseases (≥70% stenosis in one or more epicardial coronary arteries or ≥50% in the left main coronary artery) and clinical parameters. Univariate logistic regression analysis identified diabetes, angina, and/or previous infarction, clinical peripheral arterial disease and dyslipidemia as predictors of coronary artery disease. Multiple logistic regression analysis identified only diabetes and angina and/or previous infarction as independent predictors. The results corroborate previous studies demonstrating the importance of these factors when selecting patients for coronary angiography in clinical pretransplant evaluation.

  15. Local buckling and crippling of composite stiffener sections

    NASA Technical Reports Server (NTRS)

    Bonanni, David L.; Johnson, Eric R.; Starnes, James H., Jr.

    1988-01-01

    Local buckling, postbuckling, and crippling (failure) of channel, zee, and I- and J-section stiffeners made of AS4/3502 graphite-epoxy unidirectional tape are studied by experiment and analysis. Thirty-six stiffener specimens were tested statically to failure in axial compression as intermediate length columns. Web width is 1.25 inches for all specimens, and the flange width-to-thickness ratio ranges from 7 to 28 for the specimens tested. The radius of the stiffener corners is either 0.125 or 0.250 inches. A sixteen-ply orthotropic layup, an eight-ply quasi-isotropic layup, and a sixteen-ply quasi-isotropic layup are examined. Geometrically nonlinear analyses of five specimens were performed with the STAGS finite element code. Analytical results are compared to experimental data. Inplane stresses from STAGS are used to conduct a plane stress failure analysis of these specimens. Also, the development of interlaminar stress equations from equilibrium for classical laminated plate theory is presented. An algorithm to compute high order displacement derivatives required by these equations based on the Discrete Fourier Transform (DFT) is discussed.

  16. Feasibility and acceptability of a self-measurement using a portable bioelectrical impedance analysis, by the patient with chronic heart failure, in acute decompensated heart failure.

    PubMed

    Huguel, Benjamin; Vaugrenard, Thibaud; Saby, Ludivine; Benhamou, Lionel; Arméro, Sébastien; Camilleri, Élise; Langar, Aida; Alitta, Quentin; Grino, Michel; Retornaz, Frédérique

    2018-06-01

    Chronic heart failure (CHF) is a major public health matter. Mainly affecting the elderly, it is responsible for a high rate of hospitalization due to the frequency of acute heart failure (ADHF). This represents a disabling pathology for the patient and very costly for the health care system. Our study is designed to assess a connected and portable bioelectrical impedance analysis (BIA) that could reduce these hospitalizations by preventing early ADHF. This prospective study included patients hospitalized in cardiology for ADHF. Patients achieved 3 self-measurements using the BIA during their hospitalization and answered a questionnaire evaluating the acceptability of this self-measurement. The results of these measures were compared with the clinical, biological and echocardiographic criteria of patients at the same time. Twenty-three patients were included, the self-measurement during the overall duration of the hospitalization was conducted autonomously by more than 80% of the patients. The acceptability (90%) for the use of the portable BIA was excellent. Some correlations were statistically significant, such as the total water difference to the weight difference (p=0.001). There were common trends between the variation of impedance analysis measures and other evaluation criteria. The feasibility and acceptability of a self-measurement of bioelectrical impedance analysis by the patient in AHF opens up major prospects in the management of monitoring patients in CHF. The interest of this tool is the prevention of ADHF leading to hospitalization or re-hospitalizations now requires to be presented by new studies.

  17. The Obesity and Heart Failure Epidemics Among African Americans: Insights From the Jackson Heart Study.

    PubMed

    Krishnamoorthy, Arun; Greiner, Melissa A; Bertoni, Alain G; Eapen, Zubin J; O'Brien, Emily C; Curtis, Lesley H; Hernandez, Adrian F; Mentz, Robert J

    2016-08-01

    Higher rates of obesity and heart failure have been observed in African Americans, but associations with mortality are not well-described. We examined intermediate and long-term clinical implications of obesity in African Americans and associations between obesity and all-cause mortality, heart failure, and heart failure hospitalization. We conducted a retrospective analysis of a community sample of 5292 African Americans participating in the Jackson Heart Study between September 2000 and January 2013. The main outcomes were associations between body mass index (BMI) and all-cause mortality at 9 years and heart failure hospitalization at 7 years using Cox proportional hazards models and interval development of heart failure (median 8 years' follow-up) using a modified Poisson model. At baseline, 1406 (27%) participants were obese and 1416 (27%) were morbidly obese. With increasing BMI, the cumulative incidence of mortality decreased (P= .007), whereas heart failure increased (P < .001). Heart failure hospitalization was more common among morbidly obese participants (9.0%; 95% confidence interval [CI] 7.6-11.7) than among normal-weight patients (6.3%; 95% CI 4.7-8.4). After risk adjustment, BMI was not associated with mortality. Each 1-point increase in BMI was associated with a 5% increase in the risk of heart failure (hazard ratio 1.05; 95% CI 1.03-1.06; P < .001) and the risk of heart failure hospitalization for BMI greater than 32 kg/m(2) (hazard ratio 1.05; 95% CI 1.03-1.07; P < .001). Obesity and morbid obesity were common in a community sample of African Americans, and both were associated with increased heart failure and heart failure hospitalization. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Improving the performance of a filling line based on simulation

    NASA Astrophysics Data System (ADS)

    Jasiulewicz-Kaczmarek, M.; Bartkowiak, T.

    2016-08-01

    The paper describes the method of improving performance of a filling line based on simulation. This study concerns a production line that is located in a manufacturing centre of a FMCG company. A discrete event simulation model was built using data provided by maintenance data acquisition system. Two types of failures were identified in the system and were approximated using continuous statistical distributions. The model was validated taking into consideration line performance measures. A brief Pareto analysis of line failures was conducted to identify potential areas of improvement. Two improvements scenarios were proposed and tested via simulation. The outcome of the simulations were the bases of financial analysis. NPV and ROI values were calculated taking into account depreciation, profits, losses, current CIT rate and inflation. A validated simulation model can be a useful tool in maintenance decision-making process.

  19. Progressive Failure Analysis Methodology for Laminated Composite Structures

    NASA Technical Reports Server (NTRS)

    Sleight, David W.

    1999-01-01

    A progressive failure analysis method has been developed for predicting the failure of laminated composite structures under geometrically nonlinear deformations. The progressive failure analysis uses C(exp 1) shell elements based on classical lamination theory to calculate the in-plane stresses. Several failure criteria, including the maximum strain criterion, Hashin's criterion, and Christensen's criterion, are used to predict the failure mechanisms and several options are available to degrade the material properties after failures. The progressive failure analysis method is implemented in the COMET finite element analysis code and can predict the damage and response of laminated composite structures from initial loading to final failure. The different failure criteria and material degradation methods are compared and assessed by performing analyses of several laminated composite structures. Results from the progressive failure method indicate good correlation with the existing test data except in structural applications where interlaminar stresses are important which may cause failure mechanisms such as debonding or delaminations.

  20. One Size Does Not Fit All: Human Failure Event Decomposition and Task Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ronald Laurids Boring, PhD

    2014-09-01

    In the probabilistic safety assessments (PSAs) used in the nuclear industry, human failure events (HFEs) are determined as a subset of hardware failures, namely those hardware failures that could be triggered or exacerbated by human action or inaction. This approach is top-down, starting with hardware faults and deducing human contributions to those faults. Elsewhere, more traditionally human factors driven approaches would tend to look at opportunities for human errors first in a task analysis and then identify which of those errors is risk significant. The intersection of top-down and bottom-up approaches to defining HFEs has not been carefully studied. Ideally,more » both approaches should arrive at the same set of HFEs. This question remains central as human reliability analysis (HRA) methods are generalized to new domains like oil and gas. The HFEs used in nuclear PSAs tend to be top-down—defined as a subset of the PSA—whereas the HFEs used in petroleum quantitative risk assessments (QRAs) are more likely to be bottom-up—derived from a task analysis conducted by human factors experts. The marriage of these approaches is necessary in order to ensure that HRA methods developed for top-down HFEs are also sufficient for bottom-up applications. In this paper, I first review top-down and bottom-up approaches for defining HFEs and then present a seven-step guideline to ensure a task analysis completed as part of human error identification decomposes to a level suitable for use as HFEs. This guideline illustrates an effective way to bridge the bottom-up approach with top-down requirements.« less

  1. 41 CFR 102-118.410 - Can GSA suspend my agency's prepayment audit program?

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... conduct a quality assurance review. (b) A systematic or a multitude of individual failures will result in... on his or her determination of a systematic or frequent failure of the program to: (1) Conduct an...

  2. Evaluation of critical nuclear power plant electrical cable response to severe thermal fire conditions

    NASA Astrophysics Data System (ADS)

    Taylor, Gabriel James

    The failure of electrical cables exposed to severe thermal fire conditions are a safety concern for operating commercial nuclear power plants (NPPs). The Nuclear Regulatory Commission (NRC) has promoted the use of risk-informed and performance-based methods for fire protection which resulted in a need to develop realistic methods to quantify the risk of fire to NPP safety. Recent electrical cable testing has been conducted to provide empirical data on the failure modes and likelihood of fire-induced damage. This thesis evaluated numerous aspects of the data. Circuit characteristics affecting fire-induced electrical cable failure modes have been evaluated. In addition, thermal failure temperatures corresponding to cable functional failures have been evaluated to develop realistic single point thermal failure thresholds and probability distributions for specific cable insulation types. Finally, the data was used to evaluate the prediction capabilities of a one-dimension conductive heat transfer model used to predict cable failure.

  3. Improving the treatment planning and delivery process of Xoft electronic skin brachytherapy.

    PubMed

    Manger, Ryan; Rahn, Douglas; Hoisak, Jeremy; Dragojević, Irena

    2018-05-14

    To develop an improved Xoft electronic skin brachytherapy process and identify areas of further improvement. A multidisciplinary team conducted a failure modes and effects analysis (FMEA) by developing a process map and a corresponding list of failure modes. The failure modes were scored for their occurrence, severity, and detectability, and a risk priority number (RPN) was calculated for each failure mode as the product of occurrence, severity, and detectability. Corrective actions were implemented to address the higher risk failure modes, and a revised process was generated. The RPNs of the failure modes were compared between the initial process and final process to assess the perceived benefits of the corrective actions. The final treatment process consists of 100 steps and 114 failure modes. The FMEA took approximately 20 person-hours (one physician, three physicists, and two therapists) to complete. The 10 most dangerous failure modes had RPNs ranging from 336 to 630. Corrective actions were effective at addressing most failure modes (10 riskiest RPNs ranging from 189 to 310), yet the RPNs were higher than those published for alternative systems. Many of these high-risk failure modes remained due to hardware design limitations. FMEA helps guide process improvement efforts by emphasizing the riskiest steps. Significant risks are apparent when using a Xoft treatment unit for skin brachytherapy due to hardware limitations such as the lack of several interlocks, a short source lifespan, and variability in source output. The process presented in this article is expected to reduce but not eliminate these risks. Copyright © 2018 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  4. [High Pressure Gas Tanks

    NASA Technical Reports Server (NTRS)

    Quintana, Rolando

    2002-01-01

    Four high-pressure gas tanks, the basis of this study, were especially made by a private contractor and tested before being delivered to NASA Kennedy Space Center. In order to insure 100% reliability of each individual tank the staff at KSC decided to again submit the four tanks under more rigorous tests. These tests were conducted during a period from April 10 through May 8 at KSC. This application further validates the predictive safety model for accident prevention and system failure in the testing of four high-pressure gas tanks at Kennedy Space Center, called Continuous Hazard Tracking and Failure Prediction Methodology (CHTFPM). It is apparent from the variety of barriers available for a hazard control that some barriers will be more successful than others in providing protection. In order to complete the Barrier Analysis of the system, a Task Analysis and a Biomechanical Study were performed to establish the relationship between the degree of biomechanical non-conformities and the anomalies found within the system on particular joints of the body. This relationship was possible to obtain by conducting a Regression Analysis to the previously generated data. From the information derived the body segment with the lowest percentage of non-conformities was the neck flexion with 46.7%. Intense analysis of the system was conducted including Preliminary Hazard Analysis (PHA), Failure Mode and Effect Analysis (FMEA), and Barrier Analysis. These analyses resulted in the identification of occurrences of conditions, which may be becoming hazardous in the given system. These conditions, known as dendritics, may become hazards and could result in an accident, system malfunction, or unacceptable risk conditions. A total of 56 possible dendritics were identified. Work sampling was performed to observe the occurrence each dendritic. The out of control points generated from a Weighted c control chart along with a Pareto analysis indicate that the dendritics "Personnel not Wearing Proper Protective and Hose/tubing located in high-traffic area" which account for 59.18% of total dendritic frequency need to be addressed to reduce the chance of a hazard from occurring. However, the occurrences of some dendritics are more important than others. As a result immediate, from a Weighted c perspective, corrective action should be taken to ameliorate the cause of the Class A dendritic "Personnel located under suspended or moving loads" rather than just the most commonly occurring dendritics. In any case the vast majority of data obtained indicates that testing operations possess a relatively high degree of safety.

  5. Evaluation of a Progressive Failure Analysis Methodology for Laminated Composite Structures

    NASA Technical Reports Server (NTRS)

    Sleight, David W.; Knight, Norman F., Jr.; Wang, John T.

    1997-01-01

    A progressive failure analysis methodology has been developed for predicting the nonlinear response and failure of laminated composite structures. The progressive failure analysis uses C plate and shell elements based on classical lamination theory to calculate the in-plane stresses. Several failure criteria, including the maximum strain criterion, Hashin's criterion, and Christensen's criterion, are used to predict the failure mechanisms. The progressive failure analysis model is implemented into a general purpose finite element code and can predict the damage and response of laminated composite structures from initial loading to final failure.

  6. Making the Hubble Space Telescope servicing mission safe

    NASA Technical Reports Server (NTRS)

    Bahr, N. J.; Depalo, S. V.

    1992-01-01

    The implementation of the HST system safety program is detailed. Numerous safety analyses are conducted through various phases of design, test, and fabrication, and results are presented to NASA management for discussion during dedicated safety reviews. Attention is given to the system safety assessment and risk analysis methodologies used, i.e., hazard analysis, fault tree analysis, and failure modes and effects analysis, and to how they are coupled with engineering and test analysis for a 'synergistic picture' of the system. Some preliminary safety analysis results, showing the relationship between hazard identification, control or abatement, and finally control verification, are presented as examples of this safety process.

  7. Outcomes of implants and restorations placed in general dental practices: a retrospective study by the Practitioners Engaged in Applied Research and Learning (PEARL) Network.

    PubMed

    Da Silva, John D; Kazimiroff, Julie; Papas, Athena; Curro, Frederick A; Thompson, Van P; Vena, Donald A; Wu, Hongyu; Collie, Damon; Craig, Ronald G

    2014-07-01

    The authors conducted a study to determine the types, outcomes, risk factors and esthetic assessment of implants and their restorations placed in the general practices of a practice-based research network. All patients who visited network practices three to five years previously and underwent placement of an implant and restoration within the practice were invited to enroll. Practitioner-investigators (P-Is) recorded the status of the implant and restoration, characteristics of the implant site and restoration, presence of peri-implant pathology and an esthetic assessment by the P-I and patient. The P-Is classified implants as failures if the original implant was missing or had been replaced, the implant was mobile or elicited pain on percussion, there was overt clinical or radiographic evidence of pathology or excessive bone loss (> 0.2 millimeter per year after an initial bone loss of 2 mm). They classified restorations as failures if they had been replaced or if there was abutment or restoration fracture. The authors enrolled 922 implants and patients from 87 practices, with a mean (standard deviation) follow-up of 4.2 (0.6) years. Of the 920 implants for which complete data records were available, 64 (7.0 percent) were classified as failures when excessive bone loss was excluded from the analysis. When excessive bone loss was included, 172 implants (18.7 percent) were classified as failures. According to the results of univariate analysis, a history of severe periodontitis, sites with preexisting inflammation or type IV bone, cases of immediate implant placement and placement in the incisor or canine region were associated with implant failure. According to the results of multivariate analysis, sites with preexisting inflammation (odds ratio [OR] = 2.17; 95 percent confidence interval [CI], 1.41-3.34]) or type IV bone (OR = 1.99; 95 percent CI, 1.12-3.55) were associated with a greater risk of implant failure. Of the 908 surviving implants, 20 (2.2 percent) had restorations replaced or judged as needing to be replaced. The majority of P-Is and patients were satisfied with the esthetic outcomes for both the implant and restoration. These results suggest that implant survival and success rates in general dental practices may be lower than those reported in studies conducted in academic or specialty settings. The results of this study, generated in the private general practice setting, add to the evidence base to facilitate implant treatment planning.

  8. Factors Influencing Progressive Failure Analysis Predictions for Laminated Composite Structure

    NASA Technical Reports Server (NTRS)

    Knight, Norman F., Jr.

    2008-01-01

    Progressive failure material modeling methods used for structural analysis including failure initiation and material degradation are presented. Different failure initiation criteria and material degradation models are described that define progressive failure formulations. These progressive failure formulations are implemented in a user-defined material model for use with a nonlinear finite element analysis tool. The failure initiation criteria include the maximum stress criteria, maximum strain criteria, the Tsai-Wu failure polynomial, and the Hashin criteria. The material degradation model is based on the ply-discounting approach where the local material constitutive coefficients are degraded. Applications and extensions of the progressive failure analysis material model address two-dimensional plate and shell finite elements and three-dimensional solid finite elements. Implementation details are described in the present paper. Parametric studies for laminated composite structures are discussed to illustrate the features of the progressive failure modeling methods that have been implemented and to demonstrate their influence on progressive failure analysis predictions.

  9. Organizational Failure in an NHS Hospital Trust: A Qualitative Study.

    PubMed

    Ravaghi, Hamid; Mannion, Russell; Sajadi, Haniye Sadat

    2015-01-01

    The objective was to explore the key factors associated with organizational failure in an NHS Hospital Trust. This case study adopted a qualitative design. Fifty-seven semistructured interviews and document analyses were conducted as well. Data were analyzed using a framework analysis method. A range of symptoms of organizational performance failure was identified. These relate to a financial deficit, lack of good external relationships, inability to meet core targets, a lack of clear management systems, and low staff morale. These markers had not been taken seriously by the previous senior management team. Symptoms of failure were the reflection of presence of secondary and primary causes of failure. Poor managerial leadership, poor financial control and performance management, lack of open culture, distraction by 2 large projects, and the lack of clinician engagement were perceived as internal causes of failure and the high level of policy changes within the NHS as the key external cause. The level of deprivation in the area was also thought to have had a negative impact on performance. The findings reinforce and expand on those of recent studies across the public sector. Tracking an organization's performance and early diagnosis of performance problems, focusing on performance management systems, and taking into account contextual factors are issues that should be considered.

  10. A review of the success and failure characteristics of resin-bonded bridges.

    PubMed

    Miettinen, M; Millar, B J

    2013-07-01

    This literature review was designed to assess and compare the success rates and modes of failure of metal-framed, fibre-reinforced composite and all-ceramic resin-bonded bridges. A Medline search (Ovid), supplemented by hand searching, was conducted to identify prospective and retrospective cohort studies on different resin-bonded bridges within the last 16 years. A total of 49 studies met the pre-set inclusion criteria. Success rates of 25 studies on metal-framed, 17 studies on fibre-reinforced composite and 7 studies on all-ceramic resin-bonded bridges were analysed and characteristics of failures were identified. The analysis of the studies indicated an estimation of annual failure rates per year to be 4.6% (±1.3%, 95% CI) for metal-framed, 4.1% (±2.1%, 95% CI) for fibre-reinforced and 11.7% (±1.8%, 95% CI) for all-ceramic resin-bonded bridges. The most frequent complications were: debonding for metal-framed, resin-bonded bridges (93% of all failures); delamination of the composite veneering material for the fibre-reinforced bridges (41%) and fracture of the framework for the all-ceramic bridges (57%). All types of resin-bonded bridges provide an effective short- to medium-term option, with all-ceramic performing least well and having the least favourable mode of failure. The methods of failures were different for different bridges with metal frameworks performing the best over time.

  11. Habitual chocolate consumption and the risk of incident heart failure among healthy men and women.

    PubMed

    Kwok, C S; Loke, Y K; Welch, A A; Luben, R N; Lentjes, M A H; Boekholdt, S M; Pfister, R; Mamas, M A; Wareham, N J; Khaw, K-T; Myint, P K

    2016-08-01

    We aimed to examine the association between chocolate intake and the risk of incident heart failure in a UK general population. We conducted a systematic review and meta-analysis to quantify this association. We used data from a prospective population-based study, the European Prospective Investigation into Cancer (EPIC)-Norfolk cohort. Chocolate intake was quantified based on a food frequency questionnaire obtained at baseline (1993-1997) and incident heart failure was ascertained up to March 2009. We supplemented the primary data with a systematic review and meta-analysis of studies which evaluated risk of incident heart failure with chocolate consumption. A total of 20,922 participants (53% women; mean age 58 ± 9 years) were included of whom 1101 developed heart failure during the follow up (mean 12.5 ± 2.7 years, total person years 262,291 years). After adjusting for lifestyle and dietary factors, we found 19% relative reduction in heart failure incidence in the top (up to 100 g/d) compared to the bottom quintile of chocolate consumption (HR 0.81 95%CI 0.66-0.98) but the results were no longer significant after controlling for comorbidities (HR 0.87 95%CI 0.71-1.06). Additional adjustment for potential mediators did not attenuate the results further. We identified five relevant studies including the current study (N = 75,408). The pooled results showed non-significant 19% relative risk reduction of heart failure incidence with higher chocolate consumption (HR 0.81 95%CI 0.66-1.01). Our results suggest that higher chocolate intake is not associated with subsequent incident heart failure. Copyright © 2016 The Italian Society of Diabetology, the Italian Society for the Study of Atherosclerosis, the Italian Society of Human Nutrition, and the Department of Clinical Medicine and Surgery, Federico II University. Published by Elsevier B.V. All rights reserved.

  12. Plasma microvesicle analysis identifies microRNA 129-5p as a biomarker of heart failure in univentricular heart disease.

    PubMed

    Ramachandran, Sweta; Lowenthal, Alexander; Ritner, Carissa; Lowenthal, Shiri; Bernstein, Harold S

    2017-01-01

    Biomarkers of heart failure in adults have been extensively studied. However, biomarkers to monitor the progression of heart failure in children with univentricular physiology are less well understood. We proposed that as mediators of diverse pathophysiology, miRNAs contained within circulating microvesicles could serve as biomarkers for the presence and progression of heart failure in univentricular patients. To test this, we studied the association of heart failure with elevations in specific miRNAs isolated from circulating microvesicles in a cohort of children with univentricular heart disease and heart failure. We conducted a single site cross-sectional observational study of 71 children aged 1 month-7 years with univentricular heart disease and heart failure. We demonstrated that levels of miR129-5p isolated from plasma microvesicles were inversely related to the degree of clinical heart failure as assessed by Ross score. We then showed that miR129-5p levels are downregulated in HL1 cells and human embryonic stem cell-derived cardiomyocytes exposed to oxidative stress. We demonstrated that bone morphogenetic protein receptor 2, which has been implicated in the development of pulmonary vascular disease, is a target of miR129-5p, and conversely regulated in response to oxidative stress in cell culture. Levels of miR129-5p were inversely related to the degree of clinical heart failure in patients with univentricular heart disease. This study demonstrates that miR129-5p is a sensitive and specific biomarker for heart failure in univentricular heart disease independent of ventricular morphology or stage of palliation. Further study is warranted to understand the targets affected by miR129-5p with the development of heart failure in patients with univentricular physiology.

  13. Differences in Adverse Event Reporting Rates of Therapeutic Failure Between Two Once-daily Extended-release Methylphenidate Medications in Canada: Analysis of Spontaneous Adverse Event Reporting Databases.

    PubMed

    Park-Wyllie, Laura; van Stralen, Judy; Castillon, Genaro; Sherman, Stephen E; Almagor, Doron

    2017-10-01

    Our study evaluated adverse events of therapeutic failure (and specifically reduced duration of action) with the use of a branded product, Osmotic Release Oral System (OROS) methylphenidate, which is approved for the treatment of attention deficit/hyperactivity disorder, and a generic product (methylphenidate, methylphenidate ER-C), which was approved for marketing in Canada based on bioequivalence to OROS methylphenidate. This study was initiated following reports that some US-marketed generic methylphenidate ER products had substantially higher reporting rates of therapeutic failure than did the referenced brands. Through methodology similar to that used by the US Food and Drug Administration to investigate the issue with the US-marketed generic, reporting rates were calculated from cases of therapeutic failure identified in the Canadian Vigilance Adverse Reaction Online database for a 1-year period beginning 8 months after each product launch. Corresponding population exposure was estimated from the number of tablets dispensed. An in-depth analysis of narratives of individual case safety reports (ICSRs) with the use of the generic product was conducted in duplicate by 2 physicians to assess causality and to characterize the potential safety risk and clinical pattern of therapeutic failure. Similar secondary analyses were conducted on the US-marketed products. Reporting rates of therapeutic failure with the use of methylphenidate ER-C (generic) and OROS methylphenidate (brand name) were 411.5 and 37.5 cases per 100,000 patient-years, respectively (reporting rate ratio, 10.99; 95% CI, 5.93-22.21). In-depth analysis of narratives of 230 ICSRs of therapeutic failure with the Canadian-marketed generic determined that all ICSRs were either probably (60 [26%]) or possibly (170 [74%]) causally related to methylphenidate ER-C. Clinical symptoms suggestive of overdose were present in 31 reports of loss of efficacy (13.5%) and occurred primarily in the morning, and premature loss of efficacy (shorter duration of action) was described in 98 cases (42.6%) and occurred primarily in the afternoon. Impacts on social functioning, such as disruption in work or school performance or adverse social behaviors, were found in 51 cases (22.2%). The ~10-fold higher reporting rate of therapeutic failure with the generic product relative to its reference product in the present Canadian study resembles findings with US-marketed generic products. While these results should be interpreted with caution due to the limitations of spontaneous adverse event reporting, which may confound comparisons across products, similar findings nonetheless led the US Food and Drug Administration to declare in 2014 that 2 methylphenidate ER generic products in the United States were neither bioequivalent nor interchangeable with OROS methylphenidate-their reference product. Our results indicate a potential safety issue with the Canadian-marketed generic and suggest a need for further investigation by Health Canada. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  14. Investigation of short-circuit failure mechanisms of SiC MOSFETs by varying DC bus voltage

    NASA Astrophysics Data System (ADS)

    Namai, Masaki; An, Junjie; Yano, Hiroshi; Iwamuro, Noriyuki

    2018-07-01

    In this study, the experimental evaluation and numerical analysis of short-circuit mechanisms of 1200 V SiC planar and trench MOSFETs were conducted at various DC bus voltages from 400 to 800 V. Investigation of the impact of DC bus voltage on short-circuit capability yielded results that are extremely useful for many existing power electronics applications. Three failure mechanisms were identified in this study: thermal runaway, MOS channel current following device turn-off, and rupture of the gate oxide layer (gate oxide layer damage). The SiC MOSFETs experienced lattice temperatures exceeding 1000 K during the short-circuit transient; as Si insulated gate bipolar transistors (IGBTs) are not typically subject to such temperatures, the MOSFETs experienced distinct failure modes, and the mode experienced was significantly influenced by the DC bus voltage. In conclusion, suggestions regarding the SiC MOSFET design and operation methods that would enhance device robustness are proposed.

  15. Fatigue behavior of a cross-ply ceramic matrix composite subjected to tension-tension cycling with hold time. Master`s thesis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grant, S.A.

    This study was carried out to investigate the elevated temperature behavior of the SiC-MAS5 cross- ply (O/9O)4S ceramic matrix composite manufactured by Corning Inc. to fatigue with loading waveforms that combine the characteristics of stress rupture and high cycle fatigue. The test results were compiled in the form of S-N (cycles to failure), S-T (exposure time versus cycles to failure), S-S (energy exposure versus cycles to failure), normalized modulus degradation, strain progression, and hysteresis loop progression. From the mechanical behavior demonstrated by these curves, relationships between the effect of the environment and loading waveform were developed. In addition, a post-mortemmore » SEM analysis of the fracture surface was conducted and the results compared to the mechanical behavior.« less

  16. The Inclusion of In-Plane Stresses in Delamination Criteria

    NASA Technical Reports Server (NTRS)

    Fenske, Matthew T.

    1999-01-01

    A study of delamination failure was conducted with emphasis on delamination criteria. Evidence is presented which supports the inclusion of the in-plane stresses in addition to the interlaminar stress terms in delamination criteria. The delamination is characterized as the failure of a resin rich region in between ply sets. The entire six component stress state in this resin layer is calculated through a finite element analysis, averaged over a dimension of 1.75 ply thicknesses, and used in a Modified von Mises Delamination Criterion. This criterion builds onto previous criteria by including all six stress components in the interply resin layer. The MVMDC shows good correlation to experimental data. The results show that the treatment of delamination as the failure of a finite interply resin layer is a valid method and that the MVMDC, considering the full stress state, accurately indicates delamination for different laminate families.

  17. Quasi-Static 3-Point Reinforced Carbon-Carbon Bend Test and Analysis for Shuttle Orbiter Wing Leading Edge Impact Damage Thresholds

    NASA Technical Reports Server (NTRS)

    Fasanella, Edwin L.; Sotiris, Kellas

    2006-01-01

    Static 3-point bend tests of Reinforced Carbon-Carbon (RCC) were conducted to failure to provide data for additional validation of an LS-DYNA RCC model suitable for predicting the threshold of impact damage to shuttle orbiter wing leading edges. LS-DYNA predictions correlated well with the average RCC failure load, and were good in matching the load vs. deflection. However, correlating the detectable damage using NDE methods with the cumulative damage parameter in LS-DYNA material model 58 was not readily achievable. The difficulty of finding internal RCC damage with NDE and the high sensitivity of the mat58 damage parameter to the load near failure made the task very challenging. In addition, damage mechanisms for RCC due to dynamic impact of debris such as foam and ice and damage mechanisms due to a static loading were, as expected, not equivalent.

  18. Gender-specific risk factors for virologic failure in KwaZulu-Natal: Automobile ownership and financial insecurity

    PubMed Central

    HARE, Anna Q.; ORDÓÑEZ, Claudia E.; JOHNSON, Brent A.; RIO, Carlos DEL; KEARNS, Rachel A.; WU, Baohua; HAMPTON, Jane; WU, Peng; SUNPATH, Henry; MARCONI, Vincent C.

    2014-01-01

    We sought to examine which socioeconomic indicators are risk factors for virologic failure among HIV-1 infected patients receiving antiretroviral therapy in KwaZulu-Natal, South Africa. A case-control study of virologic failure was conducted among patients recruited from the outpatient clinic at McCord Hospital in Durban, South Africa between October 1, 2010 and June 30, 2012. Cases were those failing first-line antiretroviral therapy (ART), defined as viral load > 1000 copies/mL. Univariate logistic regression was performed on sociodemographic data for the outcome of virologic failure. Variables found significant (p<.05) were used in multivariate models and all models were stratified by gender. Of 158 cases and 300 controls, 35% were male and median age was 40 years. Gender stratification of models revealed automobile ownership was a risk factor among males, while variables of financial insecurity (unemployment, non-spouse family paying for care, staying with family) were risk factors for women. In this cohort, financial insecurity among women and automobile ownership among men were risk factors for virologic failure. Risk factor differences between genders demonstrate limitations of generalized risk factor analysis. PMID:25037488

  19. Subcritical crack growth in SiNx thin-film barriers studied by electro-mechanical two-point bending

    NASA Astrophysics Data System (ADS)

    Guan, Qingling; Laven, Jozua; Bouten, Piet C. P.; de With, Gijsbertus

    2013-06-01

    Mechanical failure resulting from subcritical crack growth in the SiNx inorganic barrier layer applied on a flexible multilayer structure was studied by an electro-mechanical two-point bending method. A 10 nm conducting tin-doped indium oxide layer was sputtered as an electrical probe to monitor the subcritical crack growth in the 150 nm dielectric SiNx layer carried by a polyethylene naphthalate substrate. In the electro-mechanical two-point bending test, dynamic and static loads were applied to investigate the crack propagation in the barrier layer. As consequence of using two loading modes, the characteristic failure strain and failure time could be determined. The failure probability distribution of strain and lifetime under each loading condition was described by Weibull statistics. In this study, results from the tests in dynamic and static loading modes were linked by a power law description to determine the critical failure over a range of conditions. The fatigue parameter n from the power law reduces greatly from 70 to 31 upon correcting for internal strain. The testing method and analysis tool as described in the paper can be used to understand the limit of thin-film barriers in terms of their mechanical properties.

  20. Gender-specific risk factors for virologic failure in KwaZulu-Natal: automobile ownership and financial insecurity.

    PubMed

    Hare, Anna Q; Ordóñez, Claudia E; Johnson, Brent A; Del Rio, Carlos; Kearns, Rachel A; Wu, Baohua; Hampton, Jane; Wu, Peng; Sunpath, Henry; Marconi, Vincent C

    2014-11-01

    We sought to examine which socioeconomic indicators are risk factors for virologic failure among HIV-1 infected patients receiving antiretroviral therapy (ART) in KwaZulu-Natal, South Africa. A case-control study of virologic failure was conducted among patients recruited from the outpatient clinic at McCord Hospital in Durban, South Africa between October 1, 2010 and June 30, 2012. Cases were those failing first-line ART, defined as viral load >1,000 copies/mL. Univariate logistic regression was performed on sociodemographic data for the outcome of virologic failure. Variables found significant (p < 0.05) were used in multivariate models and all models were stratified by gender. Of 158 cases and 300 controls, 35 % were male and median age was 40 years. Gender stratification of models revealed automobile ownership was a risk factor among males, while variables of financial insecurity (unemployment, non-spouse family paying for care, staying with family) were risk factors for women. In this cohort, financial insecurity among women and automobile ownership among men were risk factors for virologic failure. Risk factor differences between genders demonstrate limitations of generalized risk factor analysis.

  1. Chest Wall Thickness and Decompression Failure: A Systematic Review and Meta-analysis Comparing Anatomic Locations in Needle Thoracostomy

    PubMed Central

    Laan, Danuel V.; Vu, Trang Diem N.; Thiels, Cornelius A.; Pandian, T. K.; Schiller, Henry J.; Murad, M. Hassan; Aho, Johnathon M.

    2015-01-01

    Introduction Current Advanced Trauma Life Support guidelines recommend decompression for thoracic tension physiology using a 5-cm angiocatheter at the second intercostal space (ICS) on the midclavicular line (MCL). High failure rates occur. Through systematic review and meta-analysis, we aimed to determine the chest wall thickness (CWT) of the 2nd ICS-MCL, the 4th/5th ICS at the anterior axillary line (AAL), the 4th/5th ICS mid axillary line (MAL) and needle thoracostomy failure rates using the currently recommended 5-cm angiocatheter. Methods A comprehensive search of several databases from their inception to July 24, 2014 was conducted. The search was limited to the English language, and all study populations were included. Studies were appraised by two independent reviewers according to a priori defined PRISMA inclusion and exclusion criteria. Continuous outcomes (CWT) were evaluated using weighted mean difference and binary outcomes (failure with 5-cm needle) were assessed using incidence rate. Outcomes were pooled using the random-effects model. Results The search resulted in 34,652 studies of which 15 were included for CWT analysis, 13 for NT effectiveness. Mean CWT was 42.79 mm (95% CI, 38.78–46.81) at 2nd ICS-MCL, 39.85 mm (95% CI, 28.70–51.00) at MAL, and 34.33 mm (95% CI, 28.20–40.47) at AAL (P=0.08). Mean failure rate was 38% (95% CI, 24–54) at 2nd ICS-MCL, 31% (95% CI, 10–64) at MAL, and 13% (95% CI, 8–22) at AAL (P=0.01). Conclusion Evidence from observational studies suggests that the 4th/5th ICS-AAL has the lowest predicted failure rate of needle decompression in multiple populations. PMID:26724173

  2. Chest wall thickness and decompression failure: A systematic review and meta-analysis comparing anatomic locations in needle thoracostomy.

    PubMed

    Laan, Danuel V; Vu, Trang Diem N; Thiels, Cornelius A; Pandian, T K; Schiller, Henry J; Murad, M Hassan; Aho, Johnathon M

    2016-04-01

    Current Advanced Trauma Life Support guidelines recommend decompression for thoracic tension physiology using a 5-cm angiocatheter at the second intercostal space (ICS) on the midclavicular line (MCL). High failure rates occur. Through systematic review and meta-analysis, we aimed to determine the chest wall thickness (CWT) of the 2nd ICS-MCL, the 4th/5th ICS at the anterior axillary line (AAL), the 4th/5th ICS mid axillary line (MAL) and needle thoracostomy failure rates using the currently recommended 5-cm angiocatheter. A comprehensive search of several databases from their inception to July 24, 2014 was conducted. The search was limited to the English language, and all study populations were included. Studies were appraised by two independent reviewers according to a priori defined PRISMA inclusion and exclusion criteria. Continuous outcomes (CWT) were evaluated using weighted mean difference and binary outcomes (failure with 5-cm needle) were assessed using incidence rate. Outcomes were pooled using the random-effects model. The search resulted in 34,652 studies of which 15 were included for CWT analysis, 13 for NT effectiveness. Mean CWT was 42.79 mm (95% CI, 38.78-46.81) at 2nd ICS-MCL, 39.85 mm (95% CI, 28.70-51.00) at MAL, and 34.33 mm (95% CI, 28.20-40.47) at AAL (P=.08). Mean failure rate was 38% (95% CI, 24-54) at 2nd ICS-MCL, 31% (95% CI, 10-64) at MAL, and 13% (95% CI, 8-22) at AAL (P=.01). Evidence from observational studies suggests that the 4th/5th ICS-AAL has the lowest predicted failure rate of needle decompression in multiple populations. Level 3 SR/MA with up to two negative criteria. Therapeutic. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. Virological and immunological failure of HAART and associated risk factors among adults and adolescents in the Tigray region of Northern Ethiopia.

    PubMed

    Hailu, Genet Gebrehiwet; Hagos, Dawit Gebregziabher; Hagos, Amlsha Kahsay; Wasihun, Araya Gebreyesus; Dejene, Tsehaye Asmelash

    2018-01-01

    Human immunodeficiency virus/Acquired immunodeficiency syndrome associated morbidity and mortality has reduced significantly since the introduction of highly active antiretroviral therapy. As a result of increasing access to highly active antiretroviral therapy, the survival and quality of life of the patients has significantly improved globally. Despite this promising result, regular monitoring of people on antiretroviral therapy is recommended to ensure whether there is an effective treatment response or not. This study was designed to assess virological and immunological failure of highly active antiretroviral therapy users among adults and adolescents in the Tigray region of Northern Ethiopia, where scanty data are available. A retrospective follow up study was conducted from September 1 to December 30, 2016 to assess the magnitude and factors associated with virological and immunological failure among 260 adults and adolescents highly active antiretroviral therapy users who started first line ART between January 1, 2008 to March 1, 2016. A standardized questionnaire was used to collect socio-demographic and clinical data. SPSS Version21 statistical software was used for analysis. Bivariate and multivariate logistic regression analyses were conducted to identify factors associated to virological and immunological failure. Statistical association was declared significant if p-value was ≤ 0.05. A total of 30 (11.5%) and 17 (6.5%) participants experienced virological and immunological failure respectively in a median time of 36 months of highly active antiretroviral therapy. Virological failure was associated with non-adherence to medications, aged < 40 years old, having CD4+ T-cells count < 250 cells/μL and male gender. Similarly, immunological failure was associated with non-adherence, tuberculosis co-infection and Human immunodeficiency virus RNA ≥1000 copies/mL. The current result shows that immunological and virological failure is a problem in a setting where highly active antiretroviral therapy has been largely scale up. The problem is more in patients with poor adherence. This will in turn affect the global targets of 90% viral suppression by 2020. This may indicate the need for more investment and commitment to improving patient adherence in the study area.

  4. Virological and immunological failure of HAART and associated risk factors among adults and adolescents in the Tigray region of Northern Ethiopia

    PubMed Central

    Hailu, Genet Gebrehiwet; Hagos, Dawit Gebregziabher; Hagos, Amlsha Kahsay; Dejene, Tsehaye Asmelash

    2018-01-01

    Background Human immunodeficiency virus/Acquired immunodeficiency syndrome associated morbidity and mortality has reduced significantly since the introduction of highly active antiretroviral therapy. As a result of increasing access to highly active antiretroviral therapy, the survival and quality of life of the patients has significantly improved globally. Despite this promising result, regular monitoring of people on antiretroviral therapy is recommended to ensure whether there is an effective treatment response or not. This study was designed to assess virological and immunological failure of highly active antiretroviral therapy users among adults and adolescents in the Tigray region of Northern Ethiopia, where scanty data are available. Methods A retrospective follow up study was conducted from September 1 to December 30, 2016 to assess the magnitude and factors associated with virological and immunological failure among 260 adults and adolescents highly active antiretroviral therapy users who started first line ART between January 1, 2008 to March 1, 2016. A standardized questionnaire was used to collect socio-demographic and clinical data. SPSS Version21 statistical software was used for analysis. Bivariate and multivariate logistic regression analyses were conducted to identify factors associated to virological and immunological failure. Statistical association was declared significant if p-value was ≤ 0.05. Result A total of 30 (11.5%) and 17 (6.5%) participants experienced virological and immunological failure respectively in a median time of 36 months of highly active antiretroviral therapy. Virological failure was associated with non-adherence to medications, aged < 40 years old, having CD4+ T-cells count < 250 cells/μL and male gender. Similarly, immunological failure was associated with non-adherence, tuberculosis co-infection and Human immunodeficiency virus RNA ≥1000 copies/mL. Conclusions The current result shows that immunological and virological failure is a problem in a setting where highly active antiretroviral therapy has been largely scale up. The problem is more in patients with poor adherence. This will in turn affect the global targets of 90% viral suppression by 2020. This may indicate the need for more investment and commitment to improving patient adherence in the study area. PMID:29715323

  5. Probability of Failure Analysis Standards and Guidelines for Expendable Launch Vehicles

    NASA Astrophysics Data System (ADS)

    Wilde, Paul D.; Morse, Elisabeth L.; Rosati, Paul; Cather, Corey

    2013-09-01

    Recognizing the central importance of probability of failure estimates to ensuring public safety for launches, the Federal Aviation Administration (FAA), Office of Commercial Space Transportation (AST), the National Aeronautics and Space Administration (NASA), and U.S. Air Force (USAF), through the Common Standards Working Group (CSWG), developed a guide for conducting valid probability of failure (POF) analyses for expendable launch vehicles (ELV), with an emphasis on POF analysis for new ELVs. A probability of failure analysis for an ELV produces estimates of the likelihood of occurrence of potentially hazardous events, which are critical inputs to launch risk analysis of debris, toxic, or explosive hazards. This guide is intended to document a framework for POF analyses commonly accepted in the US, and should be useful to anyone who performs or evaluates launch risk analyses for new ELVs. The CSWG guidelines provide performance standards and definitions of key terms, and are being revised to address allocation to flight times and vehicle response modes. The POF performance standard allows a launch operator to employ alternative, potentially innovative methodologies so long as the results satisfy the performance standard. Current POF analysis practice at US ranges includes multiple methodologies described in the guidelines as accepted methods, but not necessarily the only methods available to demonstrate compliance with the performance standard. The guidelines include illustrative examples for each POF analysis method, which are intended to illustrate an acceptable level of fidelity for ELV POF analyses used to ensure public safety. The focus is on providing guiding principles rather than "recipe lists." Independent reviews of these guidelines were performed to assess their logic, completeness, accuracy, self- consistency, consistency with risk analysis practices, use of available information, and ease of applicability. The independent reviews confirmed the general validity of the performance standard approach and suggested potential updates to improve the accuracy each of the example methods, especially to address reliability growth.

  6. Design, Analysis and Testing of a PRSEUS Pressure Cube to Investigate Assembly Joints

    NASA Technical Reports Server (NTRS)

    Yovanof, Nicolette; Lovejoy, Andrew E.; Baraja, Jaime; Gould, Kevin

    2012-01-01

    Due to its potential to significantly increase fuel efficiency, the current focus of NASA's Environmentally Responsible Aviation Program is the hybrid wing body (HWB) aircraft. Due to the complex load condition that exists in HWB structure, as compared to traditional aircraft configurations, light-weight, cost-effective and manufacturable structural concepts are required to enable the HWB. The Pultruded Rod Stitched Efficient Unitized Structure (PRSEUS) concept is one such structural concept. A building block approach for technology development of the PRSEUS concept is being conducted. As part of this approach, a PRSEUS pressure cube was developed as a risk reduction test article to examine a new integral cap joint concept. This paper describes the design, analysis and testing of the PRSEUS pressure cube test article. The pressure cube was required to withstand a 2P, 18.4 psi, overpressure load requirement. The pristine pressure cube was tested to 2.2P with no catastrophic failure. After the addition of barely visible impact damage, the cube was pressure loaded to 48 psi where catastrophic failure occurred, meeting the scale-up requirement. Comparison of pretest and posttest analyses with the cube test response agree well, and indicate that current analysis methods can be used to accurately analyze PRSEUS structure for initial failure response.

  7. Vamistor resistor investigation

    NASA Technical Reports Server (NTRS)

    1973-01-01

    Results are presented of the failure investigation conducted on resistors produced by the Vamistor Divison, Wagner Electric Corporation. This failure investigation included; failure analyses, chemical and metallurgical analyses, failure mechanism studies, seal leak analyses, and nondestructive stress tests. The data, information, conclusions, and recommendation can be helpful in assessing current usage of these resistors.

  8. Loading tests of a wing structure for a hypersonic aircraft

    NASA Technical Reports Server (NTRS)

    Fields, R. A.; Reardon, L. F.; Siegel, W. H.

    1980-01-01

    Room-temperature loading tests were conducted on a wing structure designed with a beaded panel concept for a Mach 8 hypersonic research airplane. Strain, stress, and deflection data were compared with the results of three finite-element structural analysis computer programs and with design data. The test program data were used to evaluate the structural concept and the methods of analysis used in the design. A force stiffness technique was utilized in conjunction with load conditions which produced various combinations of panel shear and compression loading to determine the failure envelope of the buckling critical beaded panels The force-stiffness data did not result in any predictions of buckling failure. It was, therefore, concluded that the panels were conservatively designed as a result of design constraints and assumptions of panel eccentricities. The analysis programs calculated strains and stresses competently. Comparisons between calculated and measured structural deflections showed good agreement. The test program offered a positive demonstration of the beaded panel concept subjected to room-temperature load conditions.

  9. Adaptive Flight Control for Aircraft Safety Enhancements

    NASA Technical Reports Server (NTRS)

    Nguyen, Nhan T.; Gregory, Irene M.; Joshi, Suresh M.

    2008-01-01

    This poster presents the current adaptive control research being conducted at NASA ARC and LaRC in support of the Integrated Resilient Aircraft Control (IRAC) project. The technique "Approximate Stability Margin Analysis of Hybrid Direct-Indirect Adaptive Control" has been developed at NASA ARC to address the needs for stability margin metrics for adaptive control that potentially enables future V&V of adaptive systems. The technique "Direct Adaptive Control With Unknown Actuator Failures" is developed at NASA LaRC to deal with unknown actuator failures. The technique "Adaptive Control with Adaptive Pilot Element" is being researched at NASA LaRC to investigate the effects of pilot interactions with adaptive flight control that can have implications of stability and performance.

  10. Iatrogenesis in intensive care units: dramatization of contemporary bio/ethical problems.

    PubMed

    de Oliveira Vargas, Mara Ambrosina; Ramos, Flavia Regina Souza

    2010-01-01

    This qualitative investigation, based in Foucauldian analysis with approximations to the post-structuralism theoretical framework, explores iatrogenesis as one of the tensions in the nursing to do/to know which can be discursively articulated to bioethics and to technobiomedicine. The documentary sources and intensive interviews with nurses, permitted the activation of a reflection on the act of the nurse in a context permeated by the ever-present possibility of failure in both the procedure and in the conduct and, from this possibility, they should meet their obligation to correct this failure not so much or not only in knowledge, not so much or not only in law but in practice itself.

  11. Design and fabrication of prototype system for early warning of impending bearing failure

    NASA Technical Reports Server (NTRS)

    Meacher, J.; Chen, H. M.

    1974-01-01

    A test program was conducted with the objective of developing a method and equipment for on-line monitoring of installed ball bearings to detect deterioration or impending failure of the bearings. The program was directed at the spin-axis bearings of a control moment gyro. The bearings were tested at speeds of 6000 and 8000 rpm, thrust loads from 50 to 1000 pounds, with a wide range of lubrication conditions, with and without a simulated fatigue spall implanted in the inner race ball track. It was concluded that a bearing monitor system based on detection and analysis of modulations of a fault indicating bearing resonance frequency can provide a low threshold of sensitivity.

  12. Could Acoustic Emission Testing Show a Pipe Failure in Advance?

    NASA Astrophysics Data System (ADS)

    Soares, S. D.; Teixeira, J. C. G.

    2004-02-01

    During the last 20 years PETROBRAS has been attempting to use Acoustic Emission (AE) as an inspection tool. In this period the AE concept has changed from a revolutionary method to a way of finding areas to make a complete inspection. PETROBRAS has a lot of pressure vessels inspected by AE and with other NDTs techniques to establish their relationship. In other hand, PETROBRAS R&D Center has conducted destructive hydrostatic tests in pipelines samples with artificial defects made by milling. Those tests were monitored by acoustic emission and manual ultrasonic until the complete failure of pipe sample. This article shows the results obtained and a brief proposal of analysis criteria for this environment of test.

  13. Cost-utility analysis of the EVOLVO study on remote monitoring for heart failure patients with implantable defibrillators: randomized controlled trial.

    PubMed

    Zanaboni, Paolo; Landolina, Maurizio; Marzegalli, Maurizio; Lunati, Maurizio; Perego, Giovanni B; Guenzati, Giuseppe; Curnis, Antonio; Valsecchi, Sergio; Borghetti, Francesca; Borghi, Gabriella; Masella, Cristina

    2013-05-30

    Heart failure patients with implantable defibrillators place a significant burden on health care systems. Remote monitoring allows assessment of device function and heart failure parameters, and may represent a safe, effective, and cost-saving method compared to conventional in-office follow-up. We hypothesized that remote device monitoring represents a cost-effective approach. This paper summarizes the economic evaluation of the Evolution of Management Strategies of Heart Failure Patients With Implantable Defibrillators (EVOLVO) study, a multicenter clinical trial aimed at measuring the benefits of remote monitoring for heart failure patients with implantable defibrillators. Two hundred patients implanted with a wireless transmission-enabled implantable defibrillator were randomized to receive either remote monitoring or the conventional method of in-person evaluations. Patients were followed for 16 months with a protocol of scheduled in-office and remote follow-ups. The economic evaluation of the intervention was conducted from the perspectives of the health care system and the patient. A cost-utility analysis was performed to measure whether the intervention was cost-effective in terms of cost per quality-adjusted life year (QALY) gained. Overall, remote monitoring did not show significant annual cost savings for the health care system (€1962.78 versus €2130.01; P=.80). There was a significant reduction of the annual cost for the patients in the remote arm in comparison to the standard arm (€291.36 versus €381.34; P=.01). Cost-utility analysis was performed for 180 patients for whom QALYs were available. The patients in the remote arm gained 0.065 QALYs more than those in the standard arm over 16 months, with a cost savings of €888.10 per patient. Results from the cost-utility analysis of the EVOLVO study show that remote monitoring is a cost-effective and dominant solution. Remote management of heart failure patients with implantable defibrillators appears to be cost-effective compared to the conventional method of in-person evaluations. ClinicalTrials.gov NCT00873899; http://clinicaltrials.gov/show/NCT00873899 (Archived by WebCite at http://www.webcitation.org/6H0BOA29f).

  14. Comparison of graft survival following penetrating keratoplasty and Descemet's stripping endothelial keratoplasty in eyes with a glaucoma drainage device.

    PubMed

    Iverson, Shawn M; Spierer, Oriel; Papachristou, George C; Feuer, William J; Shi, Wei; Greenfield, David S; O'Brien, Terrence P

    2018-02-01

    To compare corneal graft survival rates after penetrating keratoplasty (PK) and Descemet's stripping endothelial keratoplasty (DSEK) in patients with a glaucoma drainage device (GDD) or medically managed glaucoma. A retrospective chart review was conducted on consecutive patients who underwent primary PK or primary DSEK. Inclusion criteria consisted of eyes with a diagnosis of glaucoma prior to corneal transplantation and a minimum of 6 months of follow-up. Graft failure was defined as an edematous cornea with failure to maintain deturgescence lasting beyond a period of 1 month of intense steroid therapy or vascularization and scarring resulting in irreversible loss of central graft clarity. Corneal graft survival was calculated using Kaplan-Meier survival analysis. Patients were divided into four groups: GDD-PK, GDD-DSEK, medical-PK and medical-DSEK. Fifty-six eyes of 56 patients were identified as meeting inclusion criteria. Among eyes with a GDD, there was no difference in the proportion of failures between PK grafts (48%) and DSEK grafts (50%) (p = 0.90). Failure occurred earlier in DSEK recipients compared to PK recipients, 5.82 ± 6.77 months versus 14.40 ± 7.70 months, respectively (p = 0.04). A Kaplan-Meier analysis did not identify a difference between the four groups with respect to graft failure (p = 0.52). There is no significant difference in graft survival rates between medically and surgically treated glaucoma patients for either PK or DSEK grafts. In patients with GDD, graft failure occurs earlier in DSEK compared to PK.

  15. [Psycho-social factors of sexual failure among newly married Uyghur young males].

    PubMed

    Erkin, Ashim; Hamrajan, Memtili; Kadirjan, Mijit; Adil, Eli; Elijan, Abdureshit; Ibrahim, Ubul; Abdulla, Tursun; Hasanjan, Abdurehim; Turgun, Hekim; Eli, Ablet; Eset, Metmusa

    2016-08-01

    To study the psycho-social risk factors of sexual failure among newly married young males in the Uyghur population. We conducted a paired case control study of 186 newly married Uyghur young males (aged 17-30 [23.4±2.9] yr) with sexual failure and another 186 (aged 18-34 [24.0±3.1] yr) with no such problem as controls. We performed a logistic regression analysis on the possible psycho-social risk factors of this condition. Logistic regression analysis showed that the risk factors of sexual failure among the newly married men included personality (OR=0.271, 95% CI 0.176-0.420), income (OR=0.391, 95% CI 0.264-0.580), history of masturbation (OR=0.824, 95% CI 0.710-0.956), premarital sex (OR=0.757, 95% CI 0.677-0.847), sense of obligation (OR=1.756, 95% CI 1.157-2.693), equality of the social status (OR=0.574, 95% CI 0.435-0.756), degree of mutual care (OR=1.605, 95% CI 1.268-2.032), female's psychological obstacle (OR=2.832, 95% CI 1.221-6.569), and religion (OR=0.643, 95% CI 0.472-0.967). There was a statistical significance in the correlation between these factors and sexual failure in the newly married males (all P<0.05). Sexual failure of newly married Uyghur young males are associated with many psycho-social factors, which necessitates sexual education among young males and particularly pre-marriage sexual education and psychological guide among both males and females.

  16. Adjusting survival estimates for premature transmitter failure: A case study from the Sacramento-San Joaquin Delta

    USGS Publications Warehouse

    Holbrook, Christopher M.; Perry, Russell W.; Brandes, Patricia L.; Adams, Noah S.

    2013-01-01

    In telemetry studies, premature tag failure causes negative bias in fish survival estimates because tag failure is interpreted as fish mortality. We used mark-recapture modeling to adjust estimates of fish survival for a previous study where premature tag failure was documented. High rates of tag failure occurred during the Vernalis Adaptive Management Plan’s (VAMP) 2008 study to estimate survival of fall-run Chinook salmon (Oncorhynchus tshawytscha) during migration through the San Joaquin River and Sacramento-San Joaquin Delta, California. Due to a high rate of tag failure, the observed travel time distribution was likely negatively biased, resulting in an underestimate of tag survival probability in this study. Consequently, the bias-adjustment method resulted in only a small increase in estimated fish survival when the observed travel time distribution was used to estimate the probability of tag survival. Since the bias-adjustment failed to remove bias, we used historical travel time data and conducted a sensitivity analysis to examine how fish survival might have varied across a range of tag survival probabilities. Our analysis suggested that fish survival estimates were low (95% confidence bounds range from 0.052 to 0.227) over a wide range of plausible tag survival probabilities (0.48–1.00), and this finding is consistent with other studies in this system. When tags fail at a high rate, available methods to adjust for the bias may perform poorly. Our example highlights the importance of evaluating the tag life assumption during survival studies, and presents a simple framework for evaluating adjusted survival estimates when auxiliary travel time data are available.

  17. Emotions and encounters with healthcare professionals as predictors for the self-estimated ability to return to work: a cross-sectional study of people with heart failure.

    PubMed

    Nordgren, Lena; Söderlund, Anne

    2016-11-09

    To live with heart failure means that life is delimited. Still, people with heart failure can have a desire to stay active in working life as long as possible. Although a number of factors affect sick leave and rehabilitation processes, little is known about sick leave and vocational rehabilitation concerning people with heart failure. This study aimed to identify emotions and encounters with healthcare professionals as possible predictors for the self-estimated ability to return to work in people on sick leave due to heart failure. A population-based cross-sectional study design was used. The study was conducted in Sweden. Data were collected in 2012 from 3 different sources: 2 official registries and 1 postal questionnaire. A total of 590 individuals were included. Descriptive statistics, correlation analysis and linear multiple regression analysis were used. 3 variables, feeling strengthened in the situation (β=-0.21, p=0.02), feeling happy (β=-0.24, p=0.02) and receiving encouragement about work (β=-0.32, p≤0.001), were identified as possible predictive factors for the self-estimated ability to return to work. To feel strengthened, happy and to receive encouragement about work can affect the return to work process for people on sick leave due to heart failure. In order to develop and implement rehabilitation programmes to meet these needs, more research is needed. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  18. Using failure mode and effects analysis to plan implementation of smart i.v. pump technology.

    PubMed

    Wetterneck, Tosha B; Skibinski, Kathleen A; Roberts, Tanita L; Kleppin, Susan M; Schroeder, Mark E; Enloe, Myra; Rough, Steven S; Hundt, Ann Schoofs; Carayon, Pascale

    2006-08-15

    Failure mode and effects analysis (FMEA) was used to evaluate a smart i.v. pump as it was implemented into a redesigned medication-use process. A multidisciplinary team conducted a FMEA to guide the implementation of a smart i.v. pump that was designed to prevent pump programming errors. The smart i.v. pump was equipped with a dose-error reduction system that included a pre-defined drug library in which dosage limits were set for each medication. Monitoring for potential failures and errors occurred for three months postimplementation of FMEA. Specific measures were used to determine the success of the actions that were implemented as a result of the FMEA. The FMEA process at the hospital identified key failure modes in the medication process with the use of the old and new pumps, and actions were taken to avoid errors and adverse events. I.V. pump software and hardware design changes were also recommended. Thirteen of the 18 failure modes reported in practice after pump implementation had been identified by the team. A beneficial outcome of FMEA was the development of a multidisciplinary team that provided the infrastructure for safe technology implementation and effective event investigation after implementation. With the continual updating of i.v. pump software and hardware after implementation, FMEA can be an important starting place for safe technology choice and implementation and can produce site experts to follow technology and process changes over time. FMEA was useful in identifying potential problems in the medication-use process with the implementation of new smart i.v. pumps. Monitoring for system failures and errors after implementation remains necessary.

  19. Is it beneficial to approximate pre-failure topography to predict landslide susceptibility with empirical models?

    NASA Astrophysics Data System (ADS)

    Steger, Stefan; Schmaltz, Elmar; Glade, Thomas

    2017-04-01

    Empirical landslide susceptibility maps spatially depict the areas where future slope failures are likely due to specific environmental conditions. The underlying statistical models are based on the assumption that future landsliding is likely to occur under similar circumstances (e.g. topographic conditions, lithology, land cover) as past slope failures. This principle is operationalized by applying a supervised classification approach (e.g. a regression model with a binary response: landslide presence/absence) that enables discrimination between conditions that favored past landslide occurrences and the circumstances typical for landslide absences. The derived empirical relation is then transferred to each spatial unit of an area. Literature reveals that the specific topographic conditions representative for landslide presences are frequently extracted from derivatives of digital terrain models at locations were past landslides were mapped. The underlying morphology-based landslide identification becomes possible due to the fact that the topography at a specific locality usually changes after landslide occurrence (e.g. hummocky surface, concave and steep scarp). In a strict sense, this implies that topographic predictors used within conventional statistical landslide susceptibility models relate to post-failure topographic conditions - and not to the required pre-failure situation. This study examines the assumption that models calibrated on the basis of post-failure topographies may not be appropriate to predict future landslide locations, because (i) post-failure and pre-failure topographic conditions may differ and (ii) areas were future landslides will occur do not yet exhibit such a distinct post-failure morphology. The study was conducted for an area located in the Walgau region (Vorarlberg, western Austria), where a detailed inventory consisting of shallow landslides was available. The methodology comprised multiple systematic comparisons of models generated on the basis of post-failure conditions (i.e. the standard approach) with models based on an approximated pre-failure topography. Pre-failure topography was approximated by (i) erasing the area of mapped landslide polygons within a digital terrain model and (ii) filling these "empty" areas by interpolating elevation points located outside the mapped landslides. Landslide presence information was extracted from the respective landslide scarp locations while an equal number of randomly sampled points represented landslide absences. After an initial exploratory data analysis, mixed-effects logistic regression was applied to model landslide susceptibility on the basis of two predictor sets (post-failure versus pre-failure predictors). Furthermore, all analyses were separately conducted for five different modelling resolutions to elaborate the suspicion that the degree of generalization of topographic parameters may as well play a role on how the respective models may differ. Model evaluation was conducted by means of multiple procedures (i.e. odds ratios, k-fold cross validation, permutation-based variable importance, difference maps of predictions). The results revealed that models based on highest resolutions (e.g. 1 m, 2.5 m) and post-failure topography performed best from a purely quantitative perspective. A confrontation of models (post-failure versus pre-failure based models) based on an identical modelling resolution exposed that validation results, modelled relationships as well as the prediction pattern tended to converge with a decreasing raster resolution. Based on the results, we concluded that an approximation of pre-failure topography does not significantly contribute to improved landslide susceptibility models in the case (i) the underlying inventory consists of small landslide features and (ii) the models are based on coarse raster resolutions (e.g. 25 m). However, in the case modelling with high raster resolutions is envisaged (e.g. 1 m, 2.5 m) or the inventory mainly consists of larger events, a reconstruction of pre-failure conditions might be highly expedient, even though conventional validation results might indicate an opposite tendency. Finally, we recommend to consider that topographic predictors highly useful to detect past slope movements (e.g. roughness) are not necessarily valuable to predict future slope instabilities.

  20. A Multi-Methods Approach to HRA and Human Performance Modeling: A Field Assessment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jacques Hugo; David I Gertman

    2012-06-01

    The Advanced Test Reactor (ATR) is a research reactor at the Idaho National Laboratory is primarily designed and used to test materials to be used in other, larger-scale and prototype reactors. The reactor offers various specialized systems and allows certain experiments to be run at their own temperature and pressure. The ATR Canal temporarily stores completed experiments and used fuel. It also has facilities to conduct underwater operations such as experiment examination or removal. In reviewing the ATR safety basis, a number of concerns were identified involving the ATR canal. A brief study identified ergonomic issues involving the manual handlingmore » of fuel elements in the canal that may increase the probability of human error and possible unwanted acute physical outcomes to the operator. In response to this concern, that refined the previous HRA scoping analysis by determining the probability of the inadvertent exposure of a fuel element to the air during fuel movement and inspection was conducted. The HRA analysis employed the SPAR-H method and was supplemented by information gained from a detailed analysis of the fuel inspection and transfer tasks. This latter analysis included ergonomics, work cycles, task duration, and workload imposed by tool and workplace characteristics, personal protective clothing, and operational practices that have the potential to increase physical and mental workload. Part of this analysis consisted of NASA-TLX analyses, combined with operational sequence analysis, computational human performance analysis (CHPA), and 3D graphical modeling to determine task failures and precursors to such failures that have safety implications. Experience in applying multiple analysis techniques in support of HRA methods is discussed.« less

  1. An analytical model to design circumferential clasps for laser-sintered removable partial dentures.

    PubMed

    Alsheghri, Ammar A; Alageel, Omar; Caron, Eric; Ciobanu, Ovidiu; Tamimi, Faleh; Song, Jun

    2018-06-21

    Clasps of removable partial dentures (RPDs) often suffer from plastic deformation and failure by fatigue; a common complication of RPDs. A new technology for processing metal frameworks for dental prostheses based on laser-sintering, which allows for precise fabrication of clasp geometry, has been recently developed. This study sought to propose a novel method for designing circumferential clasps for laser-sintered RPDs to avoid plastic deformation or fatigue failure. An analytical model for designing clasps with semicircular cross-sections was derived based on mechanics. The Euler-Bernoulli elastic curved beam theory and Castigliano's energy method were used to relate the stress and undercut with the clasp length, cross-sectional radius, alloy properties, tooth type, and retention force. Finite element analysis (FEA) was conducted on a case study and the resultant tensile stress and undercut were compared with the analytical model predictions. Pull-out experiments were conducted on laser-sintered cobalt-chromium (Co-Cr) dental prostheses to validate the analytical model results. The proposed circumferential clasp design model yields results in good agreement with FEA and experiments. The results indicate that Co-Cr circumferential clasps in molars that are 13mm long engaging undercuts of 0.25mm should have a cross-section radius of 1.2mm to provide a retention of 10N and to avoid plastic deformation or fatigue failure. However, shorter circumferential clasps such as those in premolars present high stresses and cannot avoid plastic deformation or fatigue failure. Laser-sintered Co-Cr circumferential clasps in molars are safe, whereas they are susceptible to failure in premolars. Copyright © 2018 The Academy of Dental Materials. Published by Elsevier Inc. All rights reserved.

  2. Impact of Diverse Hydrologic Pathways, 3D Failure Geometries, and Unsaturated Soil Suctions on Shallow Landsliding

    NASA Astrophysics Data System (ADS)

    Reid, M. E.; Iverson, R. M.; Brien, D. L.; Iverson, N. R.; Lahusen, R. G.; Logan, M.

    2016-12-01

    Shallow landslides and ensuing debris flows can be triggered by diverse hydrologic phenomena such as groundwater inflow, prolonged moderate-intensity precipitation, or bursts of high-intensity precipitation. However, hazard assessments typically rely on simplistic hydrologic models that disregard this diversity. We used the USGS debris-flow flume to conduct controlled, field-scale slope failure experiments designed to investigate the effects of diverse hydrologic pathways, as well as the effects of 3D landslide geometries and suction stresses in unsaturated soil. Using overhead sprinklers or groundwater injectors on the flume bed, we induced failures in 6 m3 (0.65-m thick and 2-m wide) prisms of loamy sand on a 31º slope. We used 50 sensors to monitor soil deformation, variably saturated pore pressures, and moisture changes. We also determined shear strength, hydraulic conductivity, and unsaturated moisture retention characteristics from ancillary tests. The three hydrologic scenarios noted above led to different behaviors. Groundwater injection and prolonged infiltration created differing soil moisture patterns. Intense sprinkling bursts caused rapid failure without development of widespread positive pore pressures. We simulated these observed differences numerically by coupling 2D variably saturated groundwater flow modeling and 3D limit-equilibrium analysis. We also simulated the time evolution of changes in factors of safety, and quantified the mechanical effects of 3D geometry and unsaturated soil suction on stability. When much of the soil became relatively wet, effects of 3D geometry and soil suction produced slight increases ( 10-20%) in factors of safety. Suction effects were more pronounced with drier soils. Our results indicate that simplistic models cannot consistently predict the timing of slope failure, and that high frequency monitoring (with sampling periods < 60 s) is needed to measure and interpret the effects of rapid hydrologic triggers.

  3. Analysis of a large cohort of health maintenance organization patients with congestive heart failure.

    PubMed

    Gladowski, Patricia; Fetterolf, Donald; Beals, Susan; Holleran, Mary Kay; Reich, Sanford

    2003-01-01

    The aim of this article was to measure guideline compliance in the care of health plan members diagnosed with congestive heart failure (CHF). Chart review was conducted on members with a discharge diagnosis of CHF (n = 2,697). Information was entered onto a scannable form designed by the health plan, which was coupled to an optical character recognition reader and entered into a database. Eighty-four percent of the patients had an ejection fraction (EF) measured. An angiotensin-converting enzyme inhibitor was prescribed to 72% of patients with an EF less than 40%. Comorbidities and other measures were evaluated and based on guideline recommendations. Most of the CHF patients in this health plan are being treated appropriately during posthospitalization for CHF. The use of a novel, cost-effective method for data collection resulted in the rapid acquisition of clinical data for analysis.

  4. Motivations and Predictors of Cheating in Pharmacy School

    PubMed Central

    Nguyen, Kathy; Shah, Bijal M.; Doroudgar, Shadi; Bidwal, Monica K.

    2016-01-01

    Objective. To assess the prevalence, methods, and motivations for didactic cheating among pharmacy students and to determine predictive factors for cheating in pharmacy colleges and schools. Methods. A 45-item cross-sectional survey was conducted at all four doctor of pharmacy programs in Northern California. For data analysis, t test, Fisher exact test, and logistic regression were used. Results. Overall, 11.8% of students admitted to cheating in pharmacy school. Primary motivations for cheating included fear of failure, procrastination, and stress. In multivariate analysis, the only predictor for cheating in pharmacy school was a history of cheating in undergraduate studies. Conclusion. Cheating occurs in pharmacy schools and is motivated by fear of failure, procrastination, and stress. A history of past cheating predicts pharmacy school cheating. The information presented may help programs better understand their student population and lead to a reassessment of ethical culture, testing procedures, and prevention programs. PMID:27899829

  5. Feasibility of Using Elastic Wave Velocity Monitoring for Early Warning of Rainfall-Induced Slope Failure.

    PubMed

    Chen, Yulong; Irfan, Muhammad; Uchimura, Taro; Zhang, Ke

    2018-03-27

    Rainfall-induced landslides are one of the most widespread slope instability phenomena posing a serious risk to public safety worldwide so that their temporal prediction is of great interest to establish effective warning systems. The objective of this study is to determine the effectiveness of elastic wave velocities in the surface layer of the slope in monitoring, prediction and early warning of landslide. The small-scale fixed and varied, and large-scale slope model tests were conducted. Analysis of the results has established that the elastic wave velocity continuously decreases in response of moisture content and deformation and there was a distinct surge in the decrease rate of wave velocity when failure was initiated. Based on the preliminary results of this analysis, the method using the change in elastic wave velocity proves superior for landslide early warning and suggests that a warning be issued at switch of wave velocity decrease rate.

  6. Oxidation Kinetics and Strength Degradation of Carbon Fibers in a Cracked Ceramic Matrix Composite

    NASA Technical Reports Server (NTRS)

    Halbig, Michael C.

    2003-01-01

    Experimental results and oxidation modeling will be presented to discuss carbon fiber susceptibility to oxidation, the oxidation kinetics regimes and composite strength degradation and failure due to oxidation. Thermogravimetric Analysis (TGA) was used to study the oxidation rates of carbon fiber and of a pyro-carbon interphase. The analysis was used to separately obtain activation energies for the carbon constituents within a C/SiC composite. TGA was also conducted on C/SiC composite material to study carbon oxidation and crack closure as a function of temperature. In order to more closely match applications conditions C/SiC tensile coupons were also tested under stressed oxidation conditions. The stressed oxidation tests show that C/SiC is much more susceptible to oxidation when the material is under an applied load where the cracks are open and allow for oxygen ingress. The results help correlate carbon oxidation with composite strength reduction and failure.

  7. MIC of amoxicillin/clavulanate according to CLSI and EUCAST: discrepancies and clinical impact in patients with bloodstream infections due to Enterobacteriaceae.

    PubMed

    Delgado-Valverde, Mercedes; Valiente-Mendez, Adoración; Torres, Eva; Almirante, Benito; Gómez-Zorrilla, Silvia; Borrell, Nuria; Aller-García, Ana Isabel; Gurgui, Mercedes; Almela, Manel; Sanz, Mercedes; Bou, Germán; Martínez-Martínez, Luis; Cantón, Rafael; Antonio Lepe, Jose; Causse, Manuel; Gutiérrez-Gutiérrez, Belén; Pascual, Álvaro; Rodríguez-Baño, Jesús

    2017-05-01

    To compare results of amoxicillin/clavulanate susceptibility testing using CLSI and EUCAST methodologies and to evaluate their impact on outcome in patients with bacteraemia caused by Enterobacteriaceae. A prospective observational cohort study was conducted in 13 Spanish hospitals. Patients with bacteraemia due to Enterobacteriaceae who received empirical intravenous amoxicillin/clavulanate treatment for at least 48 h were included. MICs were determined following CLSI and EUCAST recommendations. Outcome variables were: failure at the end of treatment with amoxicillin/clavulanate (FEAMC); failure at day 21; and 30 day mortality. Classification and regression tree (CART) analysis and logistic regression were performed. Overall, 264 episodes were included; the urinary tract was the most common source (64.7%) and Escherichia coli the most frequent pathogen (76.5%). Fifty-two isolates (19.7%) showed resistance according to CLSI and 141 (53.4%) according to EUCAST. The kappa index for the concordance between the results of both committees was only 0.24. EUCAST-derived, but not CLSI-derived, MICs were associated with failure when considered as continuous variables. CART analysis suggested a 'resistance' breakpoint of > 8/4 mg/L for CLSI-derived MICs; it predicted FEAMC in adjusted analysis (OR = 1.96; 95% CI: 0.98-3.90). Isolates with EUCAST-derived MICs >16/2 mg/L independently predicted FEAMC (OR = 2.10; 95% CI: 1.05-4.21) and failure at day 21 (OR= 3.01; 95% CI: 0.93-9.67). MICs >32/2 mg/L were only predictive of failure among patients with bacteraemia from urinary or biliary tract sources. CLSI and EUCAST methodologies showed low agreement for determining the MIC of amoxicillin/clavulanate. EUCAST-derived MICs seemed more predictive of failure than CLSI-derived ones. EUCAST-derived MICs >16/2 mg/L were independently associated with therapeutic failure. © The Author 2017. Published by Oxford University Press on behalf of the British Society for Antimicrobial Chemotherapy. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  8. Debonding Stress Concentrations in a Pressurized Lobed Sandwich-Walled Generic Cryogenic Tank

    NASA Technical Reports Server (NTRS)

    Ko, William L.

    2004-01-01

    A finite-element stress analysis has been conducted on a lobed composite sandwich tank subjected to internal pressure and cryogenic cooling. The lobed geometry consists of two obtuse circular walls joined together with a common flat wall. Under internal pressure and cryogenic cooling, this type of lobed tank wall will experience open-mode (a process in which the honeycomb is stretched in the depth direction) and shear stress concentrations at the junctures where curved wall changes into flat wall (known as a curve-flat juncture). Open-mode and shear stress concentrations occur in the honeycomb core at the curve-flat junctures and could cause debonding failure. The levels of contributions from internal pressure and temperature loading to the open-mode and shear debonding failure are compared. The lobed fuel tank with honeycomb sandwich walls has been found to be a structurally unsound geometry because of very low debonding failure strengths. The debonding failure problem could be eliminated if the honeycomb core at the curve-flat juncture is replaced with a solid core.

  9. Cantilever testing of sintered-silver interconnects

    DOE PAGES

    Wereszczak, Andrew A.; Chen, Branndon R.; Jadaan, Osama M.; ...

    2017-10-19

    Cantilever testing is an underutilized test method from which results and interpretations promote greater understanding of the tensile and shear failure responses of interconnects, metallizations, or bonded joints. The use and analysis of this method were pursued through the mechanical testing of sintered-silver interconnects that joined Ni/Au-plated copper pillars or Ti/Ni/Ag-plated silicon pillars to Ag-plated direct bonded copper substrates. Sintered-silver was chosen as the interconnect test medium because of its high electrical and thermal conductivities and high-temperature capability—attractive characteristics for a candidate interconnect in power electronic components and other devices. Deep beam theory was used to improve upon the estimationsmore » of the tensile and shear stresses calculated from classical beam theory. The failure stresses of the sintered-silver interconnects were observed to be dependent on test-condition and test-material-system. In conclusion, the experimental simplicity of cantilever testing, and the ability to analytically calculate tensile and shear stresses at failure, result in it being an attractive mechanical test method to evaluate the failure response of interconnects.« less

  10. Cantilever testing of sintered-silver interconnects

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wereszczak, Andrew A.; Chen, Branndon R.; Jadaan, Osama M.

    Cantilever testing is an underutilized test method from which results and interpretations promote greater understanding of the tensile and shear failure responses of interconnects, metallizations, or bonded joints. The use and analysis of this method were pursued through the mechanical testing of sintered-silver interconnects that joined Ni/Au-plated copper pillars or Ti/Ni/Ag-plated silicon pillars to Ag-plated direct bonded copper substrates. Sintered-silver was chosen as the interconnect test medium because of its high electrical and thermal conductivities and high-temperature capability—attractive characteristics for a candidate interconnect in power electronic components and other devices. Deep beam theory was used to improve upon the estimationsmore » of the tensile and shear stresses calculated from classical beam theory. The failure stresses of the sintered-silver interconnects were observed to be dependent on test-condition and test-material-system. In conclusion, the experimental simplicity of cantilever testing, and the ability to analytically calculate tensile and shear stresses at failure, result in it being an attractive mechanical test method to evaluate the failure response of interconnects.« less

  11. Anomaly Monitoring Method for Key Components of Satellite

    PubMed Central

    Fan, Linjun; Xiao, Weidong; Tang, Jun

    2014-01-01

    This paper presented a fault diagnosis method for key components of satellite, called Anomaly Monitoring Method (AMM), which is made up of state estimation based on Multivariate State Estimation Techniques (MSET) and anomaly detection based on Sequential Probability Ratio Test (SPRT). On the basis of analysis failure of lithium-ion batteries (LIBs), we divided the failure of LIBs into internal failure, external failure, and thermal runaway and selected electrolyte resistance (R e) and the charge transfer resistance (R ct) as the key parameters of state estimation. Then, through the actual in-orbit telemetry data of the key parameters of LIBs, we obtained the actual residual value (R X) and healthy residual value (R L) of LIBs based on the state estimation of MSET, and then, through the residual values (R X and R L) of LIBs, we detected the anomaly states based on the anomaly detection of SPRT. Lastly, we conducted an example of AMM for LIBs, and, according to the results of AMM, we validated the feasibility and effectiveness of AMM by comparing it with the results of threshold detective method (TDM). PMID:24587703

  12. The use of failure mode and effects analysis to construct an effective disposal and prevention mechanism for infectious hospital waste

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ho, Chao Chung, E-mail: ho919@pchome.com.tw; Liao, Ching-Jong

    Highlights: > This study is based on a real case in a regional teaching hospital in Taiwan. > We use Failure mode and effects analysis (FMEA) as the evaluation method. > We successfully identify the risk factors of infectious waste disposal. > We propose plans for the detection of exceptional cases of infectious waste. - Abstract: In recent times, the quality of medical care has been continuously improving in medical institutions wherein patient-centred care has been emphasized. Failure mode and effects analysis (FMEA) has also been promoted as a method of basic risk management and as part of total qualitymore » management (TQM) for improving the quality of medical care and preventing mistakes. Therefore, a study was conducted using FMEA to evaluate the potential risk causes in the process of infectious medical waste disposal, devise standard procedures concerning the waste, and propose feasible plans for facilitating the detection of exceptional cases of infectious waste. The analysis revealed the following results regarding medical institutions: (a) FMEA can be used to identify the risk factors of infectious waste disposal. (b) During the infectious waste disposal process, six items were scored over 100 in the assessment of uncontrolled risks: erroneous discarding of infectious waste by patients and their families, erroneous discarding by nursing staff, erroneous discarding by medical staff, cleaning drivers pierced by sharp articles, cleaning staff pierced by sharp articles, and unmarked output units. Therefore, the study concluded that it was necessary to (1) provide education and training about waste classification to the medical staff, patients and their families, nursing staff, and cleaning staff; (2) clarify the signs of caution; and (3) evaluate the failure mode and strengthen the effects.« less

  13. Design of High Altitude Long Endurance UAV: Structural Analysis of Composite Wing using Finite Element Method

    NASA Astrophysics Data System (ADS)

    Kholish Rumayshah, Khodijah; Prayoga, Aditya; Mochammad Agoes Moelyadi, Ing., Dr.

    2018-04-01

    Research on a High Altitude Long Endurance (HALE) Unmanned Aerial Vehicle (UAV) is currently being conducted at Bandung Institute of Technology (ITB). Previously, the 1st generation of HALE UAV ITB used balsa wood for most of its structure. Flight test gave the result of broken wings due to extreme side-wind that causes large bending to its high aspect ratio wing. This paper conducted a study on designing the 2nd generation of HALE UAV ITB which used composite materials in order to substitute balsa wood at some critical parts of the wing’s structure. Finite element software ABAQUS/CAE is used to predict the stress and deformation that occurred. Tsai-Wu and Von-Mises failure criteria were applied to check whether the structure failed or not. The initial configuration gave the results that the structure experienced material failure. A second iteration was done by proposing a new configuration and it was proven safe against the load given.

  14. Systematic review of studies on telemonitoring of patients with congestive heart failure: a meta-analysis.

    PubMed

    Clarke, Malcolm; Shah, Anila; Sharma, Urvashi

    2011-01-01

    We conducted a systematic review of large, well-conducted randomised trials designed to evaluate the effectiveness of telemonitoring on patients with congestive heart failure (CHF). Two people reviewed 125 articles independently and selected 13 articles for final review. These studies concerned 3480 patients. The follow-up period of the studies was 3-15 months. Pooled estimate results showed that there was an overall reduction in all-cause mortality (P = 0.02). There was no overall reduction in all-cause hospital admission (P = 0.84), although there was a reduction in CHF hospital admission (P = 0.0004). There was no reduction in all-cause emergency admission (P = 0.67). There was no significant difference in length of stay in hospital, medication adherence or cost. Telemonitoring in conjunction with nurse home visiting and specialist unit support can be effective in the clinical management of patients with CHF and help to improve their quality of life.

  15. Structural analysis of cylindrical thrust chambers, volume 1

    NASA Technical Reports Server (NTRS)

    Armstrong, W. H.

    1979-01-01

    Life predictions of regeneratively cooled rocket thrust chambers are normally derived from classical material fatigue principles. The failures observed in experimental thrust chambers do not appear to be due entirely to material fatigue. The chamber coolant walls in the failed areas exhibit progressive bulging and thinning during cyclic firings until the wall stress finally exceeds the material rupture stress and failure occurs. A preliminary analysis of an oxygen free high conductivity (OFHC) copper cylindrical thrust chamber demonstrated that the inclusion of cumulative cyclic plastic effects enables the observed coolant wall thinout to be predicted. The thinout curve constructed from the referent analysis of 10 firing cycles was extrapolated from the tenth cycle to the 200th cycle. The preliminary OFHC copper chamber 10-cycle analysis was extended so that the extrapolated thinout curve could be established by performing cyclic analysis of deformed configurations at 100 and 200 cycles. Thus the original range of extrapolation was reduced and the thinout curve was adjusted by using calculated thinout rates at 100 and 100 cycles. An analysis of the same underformed chamber model constructed of half-hard Amzirc to study the effect of material properties on the thinout curve is included.

  16. Plasma process control with optical emission spectroscopy

    NASA Astrophysics Data System (ADS)

    Ward, P. P.

    Plasma processes for cleaning, etching and desmear of electronic components and printed wiring boards (PWB) are difficult to predict and control. Non-uniformity of most plasma processes and sensitivity to environmental changes make it difficult to maintain process stability from day to day. To assure plasma process performance, weight loss coupons or post-plasma destructive testing must be used. The problem with these techniques is that they are not real-time methods and do not allow for immediate diagnosis and process correction. These methods often require scrapping some fraction of a batch to insure the integrity of the rest. Since these methods verify a successful cycle with post-plasma diagnostics, poor test results often determine that a batch is substandard and the resulting parts unusable. Both of these methods are a costly part of the overall fabrication cost. A more efficient method of testing would allow for constant monitoring of plasma conditions and process control. Process failures should be detected before the parts being treated. are damaged. Real time monitoring would allow for instantaneous corrections. Multiple site monitoring would allow for process mapping within one system or simultaneous monitoring of multiple systems. Optical emission spectroscopy conducted external to the plasma apparatus would allow for this sort of multifunctional analysis without perturbing the glow discharge. In this paper, optical emission spectroscopy for non-intrusive, in situ process control will be explored. A discussion of this technique as it applies towards process control, failure analysis and endpoint determination will be conducted. Methods for identifying process failures, progress and end of etch back and desmear processes will be discussed.

  17. Satellite vulnerability to space debris - an improved 3D risk assessment methodology

    NASA Astrophysics Data System (ADS)

    Grassi, Lilith; Tiboldo, Francesca; Destefanis, Roberto; Donath, Thérèse; Winterboer, Arne; Evans, Leanne; Janovsky, Rolf; Kempf, Scott; Rudolph, Martin; Schäfer, Frank; Gelhaus, Johannes

    2014-06-01

    The work described in the present paper, performed as a part of the P2 project, presents an enhanced method to evaluate satellite vulnerability to micrometeoroids and orbital debris (MMOD), using the ESABASE2/Debris tool (developed under ESA contract). Starting from the estimation of induced failures on spacecraft (S/C) components and from the computation of lethal impacts (with an energy leading to the loss of the satellite), and considering the equipment redundancies and interactions between components, the debris-induced S/C functional impairment is assessed. The developed methodology, illustrated through its application to a case study satellite, includes the capability to estimate the number of failures on internal components, overcoming the limitations of current tools which do not allow propagating the debris cloud inside the S/C. The ballistic limit of internal equipment behind a sandwich panel structure is evaluated through the implementation of the Schäfer Ryan Lambert (SRL) Ballistic Limit Equation (BLE). The analysis conducted on the case study satellite shows the S/C vulnerability index to be in the range of about 4% over the complete mission, with a significant reduction with respect to the results typically obtained with the traditional analysis, which considers as a failure the structural penetration of the satellite structural panels. The methodology has then been applied to select design strategies (additional local shielding, relocation of components) to improve S/C protection with respect to MMOD. The results of the analyses conducted on the improved design show a reduction of the vulnerability index of about 18%.

  18. [Modal failure analysis and effects in the detection of errors in the transport of samples to the clinical laboratory].

    PubMed

    Parés-Pollán, L; Gonzalez-Quintana, A; Docampo-Cordeiro, J; Vargas-Gallego, C; García-Álvarez, G; Ramos-Rodríguez, V; Diaz Rubio-García, M P

    2014-01-01

    Owing to the decrease in values of biochemical glucose parameter in some samples from external extraction centres, and the risk this implies to patient safety; it was decided to apply an adaptation of the «Health Services Failure Mode and Effects Analysis» (HFMEA) to manage risk during the pre-analytical phase of sample transportation from external centres to clinical laboratories. A retrospective study of glucose parameter was conducted during two consecutive months. The analysis was performed in its different phases: to define the HFMEA topic, assemble the team, graphically describe the process, conduct a hazard analysis, design the intervention and indicators, and identify a person to be responsible for ensuring completion of each action. The results of glucose parameter in one of the transport routes, were significantly lower (P=.006). The errors and potential causes of this problem were analysed, and criteria of criticality and detectability were applied (score≥8) in the decision tree. It was decided to: develop a document management system; reorganise extractions and transport routes in some centres; quality control of the sample container ice-packs, and the time and temperature during transportation. This work proposes quality indicators for controlling time and temperature of transported samples in the pre-analytical phase. Periodic review of certain laboratory parameters can help to detect problems in transporting samples. The HFMEA technique is useful for the clinical laboratory. Copyright © 2013 SECA. Published by Elsevier Espana. All rights reserved.

  19. Conceptual and Preliminary Design of a Low-Cost Precision Aerial Delivery System

    DTIC Science & Technology

    2016-06-01

    test results. It includes an analysis of the failure modes encountered during flight experimentation , methodology used for conducting coordinate...and experimentation . Additionally, the current and desired end state of the research is addressed. Finally, this chapter outlines the methodology ...preliminary design phases are utilized to investigate and develop a potentially low-cost alternative to existing systems. Using an Agile methodology

  20. Assessment of Damage Containment Features of a Full-Scale PRSEUS Fuselage Panel Through Test and Teardown

    NASA Technical Reports Server (NTRS)

    Bergan, Andrew C.; Bakuckas, John G., Jr.; Lovejoy, Andrew E.; Jegley, Dawn C.; Awerbuch, Jonathan; Tan, Tein-Min

    2012-01-01

    An area that shows promise in enhancing structural integrity of aircraft and aerospace structures is the integrally stitched composite technology. The most recent generation of this technology is the Pultruded Rod Stitched Efficient Unitized Structure (PRSEUS) concept developed by Boeing Research and Technology and the National Aeronautics and Space Administration. A joint test program on the assessment of damage containment capabilities of the PRSEUS concept for curved fuselage structures was conducted recently at the Federal Aviation Administration William J. Hughes Technical Center. The panel was subjected to axial tension, internal pressure, and combined axial tension and internal pressure load conditions up to fracture, with a through-the-thickness, two-bay notch severing the central stiffener. For the purpose of future progressive failure analysis development and verification, extensive post failure nondestructive and teardown inspections were conducted. Detailed inspections were performed directly ahead of the notch tip where stable damage progression was observed. These examinations showed: 1) extensive delaminations developed ahead of the notch tip, 2) the extent and location of damage, 3) the typical damage mechanisms observed in composites, and 4) the role of stitching and warp-knitting in the failure mechanisms. The objective of this paper is to provide a summary of results from these posttest inspections.

  1. Storm-Induced Slope Failure Susceptibility Mapping

    DOT National Transportation Integrated Search

    2018-01-01

    A pilot study was conducted to characterize and map the areas susceptible to slope failure using state-wide available data. The objective was to determine whether it would be possible to provide slope-failure susceptibility mapping that could be used...

  2. Higher-Than-Conventional Radiation Doses in Localized Prostate Cancer Treatment: A Meta-analysis of Randomized, Controlled Trials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Viani, Gustavo Arruda; Stefano, Eduardo Jose; Afonso, Sergio Luis

    2009-08-01

    Purpose: To determine in a meta-analysis whether the outcomes in men with localized prostate cancer treated with high-dose radiotherapy (HDRT) are better than those in men treated with conventional-dose radiotherapy (CDRT), by quantifying the effect of the total dose of radiotherapy on biochemical control (BC). Methods and Materials: The MEDLINE, EMBASE, CANCERLIT, and Cochrane Library databases, as well as the proceedings of annual meetings, were systematically searched to identify randomized, controlled studies comparing HDRT with CDRT for localized prostate cancer. To evaluate the dose-response relationship, we conducted a meta-regression analysis of BC ratios by means of weighted linear regression. Results:more » Seven RCTs with a total patient population of 2812 were identified that met the study criteria. Pooled results from these RCTs showed a significant reduction in the incidence of biochemical failure in those patients with prostate cancer treated with HDRT (p < 0.0001). However, there was no difference in the mortality rate (p = 0.38) and specific prostate cancer mortality rates (p = 0.45) between the groups receiving HDRT and CDRT. However, there were more cases of late Grade >2 gastrointestinal toxicity after HDRT than after CDRT. In the subgroup analysis, patients classified as being at low (p = 0.007), intermediate (p < 0.0001), and high risk (p < 0.0001) of biochemical failure all showed a benefit from HDRT. The meta-regression analysis also detected a linear correlation between the total dose of radiotherapy and biochemical failure (BC = -67.3 + [1.8 x radiotherapy total dose in Gy]; p = 0.04). Conclusions: Our meta-analysis showed that HDRT is superior to CDRT in preventing biochemical failure in low-, intermediate-, and high-risk prostate cancer patients, suggesting that this should be offered as a treatment for all patients, regardless of their risk status.« less

  3. A multiscale structural investigation of the annulus-endplate anchorage system and its mechanisms of failure.

    PubMed

    Rodrigues, Samantha A; Thambyah, Ashvin; Broom, Neil D

    2015-03-01

    The annulus-endplate anchorage system performs a critical role in the disc, creating a strong structural link between the compliant annulus and the rigid vertebrae. Endplate failure is thought to be associated with disc herniation, a recent study indicating that this failure mode occurs more frequently than annular rupture. The aim was to investigate the structural principles governing annulus-endplate anchorage and the basis of its strength and mechanisms of failure. Loading experiments were performed on ovine lumbar motion segments designed to induce annulus-endplate failure, followed by macro- to micro- to fibril-level structural analyses. The study was funded by a doctoral scholarship from our institution. Samples were loaded to failure in three modes: torsion using intact motion segments, in-plane tension of the anterior annulus-endplate along one of the oblique fiber angles, and axial tension of the anterior annulus-endplate. The anterior region was chosen for its ease of access. Decalcification was used to investigate the mechanical influence of the mineralized component. Structural analysis was conducted on both the intact and failed samples using differential interference contrast optical microscopy and scanning electron microscopy. Two main modes of anchorage failure were observed--failure at the tidemark or at the cement line. Samples subjected to axial tension contained more tidemark failures compared with those subjected to torsion and in-plane tension. Samples decalcified before testing frequently contained damage at the cement line, this being more extensive than in fresh samples. Analysis of the intact samples at their anchorage sites revealed that annular subbundle fibrils penetrate beyond the cement line to a limited depth and appear to merge with those in the vertebral and cartilaginous endplates. Annulus-endplate anchorage is more vulnerable to failure in axial tension compared with both torsion and in-plane tension and is probably due to acute fiber bending at the soft-hard interface of the tidemark. This finding is consistent with evidence showing that flexion, which induces a similar pattern of axial tension, increases the risk of herniation involving endplate failure. The study also highlights the important strengthening role of calcification at this junction and provides new evidence of a fibril-based form of structural integration across the cement line. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. The association of platelets with failed patent ductus arteriosus closure after a primary course of indomethacin or ibuprofen: a systematic review and meta-analysis.

    PubMed

    Mitra, Souvik; Chan, Anthony K; Paes, Bosco A

    2017-01-01

    To conduct a meta-analysis of the association of platelet counts and pharmacotherapeutic failure in preterms with a patent ductus arteriosus (PDA). MEDLINE, Embase, Science Citation Index, abstracts and conference proceedings were searched, and principal authors contacted. Included studies reported indomethacin or ibuprofen use for PDA closure, compared a group which failed treatment versus a group which did not and reported the association between platelet counts and indomethacin or ibuprofen failure. Two reviewers independently screened results and assessed methodological quality using the Newcastle-Ottawa Scale. Results are expressed as mean difference in platelet counts and summary odds ratios (OR) using a random effects model. 1105 relevant studies were identified; eight involving 1087 preterms were included. Platelet counts were significantly lower in infants who failed pharmacotherapy (Meandifference:-30.88 × 10 9 /L; 95% CI:-45.69 × 10 9 ,-16.07 × 10 9 /L; I2 = 24%; p heterogeneity  =   0.24). Similar results were obtained based on either pharmacotherapeutic agent. Treatment failure was also significantly associated with pre-treatment thrombocytopenia (summary OR:1.75; 95% CI:1.23-2.49, I2 = 36%, p heterogeneity  =   0.20). Platelet counts are significantly lower in preterms who fail primary treatment for PDA. Pre-treatment thrombocytopenia is associated with higher odds of failure. Further cohort studies reporting platelet counts in prostaglandin inhibitor failure are needed for meta-analyses to firmly establish or refute a stronger association.

  5. Multiscale Analysis of Nanocomposites and Their Use in Structural Level Applications

    NASA Astrophysics Data System (ADS)

    Hasan, Zeaid

    This research focuses on the benefits of using nanocomposites in aerospace structural components to prevent or delay the onset of unique composite failure modes, such as delamination. Analytical, numerical, and experimental analyses were conducted to provide a comprehensive understanding of how carbon nanotubes (CNTs) can provide additional structural integrity when they are used in specific hot spots within a structure. A multiscale approach was implemented to determine the mechanical and thermal properties of the nanocomposites, which were used in detailed finite element models (FEMs) to analyze interlaminar failures in T and Hat section stringers. The delamination that first occurs between the tow filler and the bondline between the stringer and skin was of particular interest. Both locations are considered to be hot spots in such structural components, and failures tend to initiate from these areas. In this research, nanocomposite use was investigated as an alternative to traditional methods of suppressing delamination. The stringer was analyzed under different loading conditions and assuming different structural defects. Initial damage, defined as the first drop in the load displacement curve was considered to be a useful variable to compare the different behaviors in this study and was detected via the virtual crack closure technique (VCCT) implemented in the FE analysis. Experiments were conducted to test T section skin/stringer specimens under pull-off loading, replicating those used in composite panels as stiffeners. Two types of designs were considered: one using pure epoxy to fill the tow region and another that used nanocomposite with 5 wt. % CNTs. The response variable in the tests was the initial damage. Detailed analyses were conducted using FEMs to correlate with the experimental data. The correlation between both the experiment and model was satisfactory. Finally, the effects of thermal cure and temperature variation on nanocomposite structure behavior were studied, and both variables were determined to influence the nanocomposite structure performance.

  6. Welding of Al6061and Al6082-Cu composite by friction stir processing

    NASA Astrophysics Data System (ADS)

    Iyer, R. B.; Dhabale, R. B.; Jatti, V. S.

    2016-09-01

    Present study aims at investigating the influence of process parameters on the microstructure and mechanical properties such as tensile strength and hardness of the dissimilar metal without and with copper powder. Before conducting the copper powder experiments, optimum process parameters were obtained by conducting experiments without copper powder. Taguchi's experimental L9 orthogonal design layout was used to carry out the experiments without copper powder. Threaded pin tool geometry was used for conducting the experiments. Based on the experimental results and Taguchi's analysis it was found that maximum tensile strength of 66.06 MPa was obtained at 1400 rpm spindle speed and weld speed of 20 mm/min. Maximum micro hardness (92 HV) was obtained at 1400 rpm spindle speed and weld speed of 16 mm/min. At these optimal setting of process parameters aluminium alloys were welded with the copper powder. Experimental results demonstrated that the tensile strength (96.54 MPa) and micro hardness (105 HV) of FSW was notably affected by the addition of copper powder when compared with FSW joint without copper powder. Tensile failure specimen was analysed using Scanning Electron Microscopy in order to study the failure mechanism.

  7. Forensic Study of Early Failures with Unbonded Concrete Overlays

    DOT National Transportation Integrated Search

    2017-11-01

    A forensic investigation was conducted to identify failure mechanisms responsible for early failures of unbonded concrete overlays on selected projects in Ohio, including I-70 in Madison County, I-77 in Washington and Noble Counties, and I-90 in Lake...

  8. Salvage Surgery for Locoregional Failure in Anal Squamous Cell Carcinoma.

    PubMed

    Guerra, Glen R; Kong, Joseph C; Bernardi, Maria-Pia; Ramsay, Robert G; Phillips, Wayne A; Warrier, Satish K; Lynch, A Craig; Ngan, Samuel Y; Heriot, Alexander G

    2018-02-01

    Anal squamous cell carcinoma is a rare cancer with a high cure rate, making research into the treatment of locoregional failure difficult. The purpose of this study was to examine factors related to local treatment failure and determine the outcomes of patients undergoing local salvage resection. This was a retrospective cohort study. This study was conducted at a quaternary referral center. Patients with anal squamous cell carcinoma treated with chemoradiotherapy between January 1983 and December 2015 were included. The influence of patient-, tumor-, and treatment-related factors on the primary outcome measures of locoregional failure, overall survival, and disease-free survival were investigated. Of 467 patients with anal squamous cell carcinoma, 63 experienced locoregional failure with 41 undergoing salvage resection. Twenty-seven patients (38%) had persistent disease and 36 (62%) developed locoregional recurrence. Multivariate analysis identified tumor stage (HR, 3.16; p < 0.002) as an independent predictor of locoregional failure. Thirty abdominoperineal resections and 11 pelvic exenterations were undertaken with no surgical mortality. At a median follow-up of 20 months (range, 4-150 months), 5-year overall and disease-free survival for the salvage cohort was 51% and 47%. Margin positivity was an independent predictor for relapse post-salvage surgery on multivariate analysis (HR, 20.1; p = 0.027). Nineteen patients (48%) developed further relapse, which included all 10 patients with a positive resection margin, 3 of whom underwent re-resection. Of the 19 patients with relapse, 3 remain alive and 2 have persistent disease. Limitations include the retrospective nature of the database, the prolonged time period of the study, and episodes of incomplete data. Advanced T stage is an independent predictor of local failure in anal squamous cell carcinoma. Most patients can be salvaged, with a positive resection margin being a strong predictor of further relapse and poor outcome. See Video Abstract at http://links.lww.com/DCR/A515.

  9. Identification of Modeling Approaches To Support Common-Cause Failure Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Korsah, Kofi; Wood, Richard Thomas

    2015-06-01

    Experience with applying current guidance and practices for common-cause failure (CCF) mitigation to digital instrumentation and control (I&C) systems has proven problematic, and the regulatory environment has been unpredictable. The impact of CCF vulnerability is to inhibit I&C modernization and, thereby, challenge the long-term sustainability of existing plants. For new plants and advanced reactor concepts, the issue of CCF vulnerability for highly integrated digital I&C systems imposes a design burden resulting in higher costs and increased complexity. The regulatory uncertainty regarding which mitigation strategies are acceptable (e.g., what diversity is needed and how much is sufficient) drives designers to adoptmore » complicated, costly solutions devised for existing plants. The conditions that constrain the transition to digital I&C technology by the U.S. nuclear industry require crosscutting research to resolve uncertainty, demonstrate necessary characteristics, and establish an objective basis for qualification of digital technology for usage in Nuclear Power Plant (NPP) I&C applications. To fulfill this research need, Oak Ridge National Laboratory is conducting an investigation into mitigation of CCF vulnerability for nuclear-qualified applications. The outcome of this research is expected to contribute to a fundamentally sound, comprehensive technical basis for establishing the qualification of digital technology for nuclear power applications. This report documents the investigation of modeling approaches for representing failure of I&C systems. Failure models are used when there is a need to analyze how the probability of success (or failure) of a system depends on the success (or failure) of individual elements. If these failure models are extensible to represent CCF, then they can be employed to support analysis of CCF vulnerabilities and mitigation strategies. Specifically, the research findings documented in this report identify modeling approaches that can be adapted to contribute to the basis for developing systematic methods, quantifiable measures, and objective criteria for evaluating CCF vulnerabilities and mitigation strategies.« less

  10. Analysis of rainfall-induced slope instability using a field of local factor of safety

    USGS Publications Warehouse

    Lu, Ning; Şener-Kaya, Başak; Wayllace, Alexandra; Godt, Jonathan W.

    2012-01-01

    Slope-stability analyses are mostly conducted by identifying or assuming a potential failure surface and assessing the factor of safety (FS) of that surface. This approach of assigning a single FS to a potentially unstable slope provides little insight on where the failure initiates or the ultimate geometry and location of a landslide rupture surface. We describe a method to quantify a scalar field of FS based on the concept of the Coulomb stress and the shift in the state of stress toward failure that results from rainfall infiltration. The FS at each point within a hillslope is called the local factor of safety (LFS) and is defined as the ratio of the Coulomb stress at the current state of stress to the Coulomb stress of the potential failure state under the Mohr-Coulomb criterion. Comparative assessment with limit-equilibrium and hybrid finite element limit-equilibrium methods show that the proposed LFS is consistent with these approaches and yields additional insight into the geometry and location of the potential failure surface and how instability may initiate and evolve with changes in pore water conditions. Quantitative assessments applying the new LFS field method to slopes under infiltration conditions demonstrate that the LFS has the potential to overcome several major limitations in the classical FS methodologies such as the shape of the failure surface and the inherent underestimation of slope instability. Comparison with infinite-slope methods, including a recent extension to variably saturated conditions, shows further enhancement in assessing shallow landslide occurrence using the LFS methodology. Although we use only a linear elastic solution for the state of stress with no post-failure analysis that require more sophisticated elastoplastic or other theories, the LFS provides a new means to quantify the potential instability zones in hillslopes under variably saturated conditions using stress-field based methods.

  11. Cycles till failure of silver-zinc cells with competing failure modes - Preliminary data analysis

    NASA Technical Reports Server (NTRS)

    Sidik, S. M.; Leibecki, H. F.; Bozek, J. M.

    1980-01-01

    The data analysis of cycles to failure of silver-zinc electrochemical cells with competing failure modes is presented. The test ran 129 cells through charge-discharge cycles until failure; preliminary data analysis consisted of response surface estimate of life. Batteries fail through low voltage condition and an internal shorting condition; a competing failure modes analysis was made using maximum likelihood estimation for the extreme value life distribution. Extensive residual plotting and probability plotting were used to verify data quality and selection of model.

  12. Motivational Interviewing Tailored Interventions for Heart Failure (MITI-HF): study design and methods.

    PubMed

    Masterson Creber, Ruth; Patey, Megan; Dickson, Victoria Vaughan; DeCesaris, Marissa; Riegel, Barbara

    2015-03-01

    Lack of engagement in self-care is common among patients needing to follow a complex treatment regimen, especially patients with heart failure who are affected by comorbidity, disability and side effects of poly-pharmacy. The purpose of Motivational Interviewing Tailored Interventions for Heart Failure (MITI-HF) is to test the feasibility and comparative efficacy of an MI intervention on self-care, acute heart failure physical symptoms and quality of life. We are conducting a brief, nurse-led motivational interviewing randomized controlled trial to address behavioral and motivational issues related to heart failure self-care. Participants in the intervention group receive home and phone-based motivational interviewing sessions over 90-days and those in the control group receive care as usual. Participants in both groups receive patient education materials. The primary study outcome is change in self-care maintenance from baseline to 90-days. This article presents the study design, methods, plans for statistical analysis and descriptive characteristics of the study sample for MITI-HF. Study findings will contribute to the literature on the efficacy of motivational interviewing to promote heart failure self-care. We anticipate that using an MI approach can help patients with heart failure focus on their internal motivation to change in a non-confrontational, patient-centered and collaborative way. It also affirms their ability to practice competent self-care relevant to their personal health goals. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. 40 CFR 141.211 - Special notice for repeated failure to conduct monitoring of the source water for Cryptosporidium...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... determine whether water treatment at the (treatment plant name) is sufficient to adequately remove... source of your drinking water for Cryptosporidium in order to determine by (date) whether water treatment... conduct monitoring of the source water for Cryptosporidium and for failure to determine bin classification...

  14. 49 CFR Appendix D to Part 230 - Civil Penalty Schedule

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... the boiler 1,000 2,000 230.36Hydrostatic testing of boilers: (a) Failure to perform hydrostatic test of boiler as required 1,500 3,000 (b) Failure to properly perform hydrostatic test 1,500 3,000 (c) Failure to properly inspect boiler after conducting hydrostatic test above MAWP 1,500 3,000 230.37 Failure...

  15. [Clinical, microbiological and evolutionary profile of patients experiencing failures and relapses of tuberculosis in Ivory Coast].

    PubMed

    Kouamé-N'Takpé, N; Horo, K; Koné, A; N'guessan, K R; Touré, K; Kouadio, C; Assi, D; Coulibaly, I; Kouakou, A

    2015-02-01

    Multidrug-resistant tuberculosis (MDR-TB) is a major obsession for TB control. The main risk factor for MDR-TB remains a history of TB treatment especially bad conduct. The objective of this study is to describe the profile of patients in situations of failure and relapse of tuberculosis. We performed a retrospective survey of the analysis of records of patients starting TB retreatment for failure or relapse of tuberculosis. We used 193 cases with results of culture-sensitivity. The proportion of failure is 59/193 (30.6 %) and cases of relapse are 134/193 (69.4 %). The proportion of married life is 23.4 % (11/47) in chess against 41.5 % (51/123) in relapse of TB [P=0.021, OR=0.431 (0.201 to 0.927)]. Patients failing therapy have more chest pain [5.8 % (3/52) versus 0 % (0/126) with P=0.024]. The proportion of MDR-TB was 61.4 (38/59) in case of failure against 41 % (55/134) in case of relapse [P=0.002, OR=2.599 (1.378 to 4.902)]. The evolution is the same whatever the indication of reprocessing. The proportion of MDR-TB is very important in case of reprocessing failure and relapse of tuberculosis. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  16. Higher complication risk of totally implantable venous access port systems in patients with advanced cancer - a single institution retrospective analysis.

    PubMed

    Chang, Yi-Fang; Lo, An-Chi; Tsai, Chung-Hsin; Lee, Pei-Yi; Sun, Shen; Chang, Te-Hsin; Chen, Chien-Chuan; Chang, Yuan-Shin; Chen, Jen-Ruei

    2013-02-01

    Totally implantable port systems are generally recommended for prolonged central venous access in diverse settings, but their risk of complications remains unclear for patients with advanced cancer. The aim of this study was to assess the risk of port system failure in patients with advanced cancer. We conducted a retrospective cohort study in a comprehensive cancer centre. A detailed chart review was conducted among 566 patients with 573 ports inserted during January-June, 2009 (average 345.3 catheter-days). Cox regression analysis was applied to evaluate factors during insertion and early maintenance that could lead to premature removal of the port systems due to infection or occlusion. Port system-related infection was significantly associated with receiving palliative care immediately after implantation (hazard ratio, HR = 7.3, 95% confidence interval, 95% CI = 1.2-46.0), after adjusting for probable confounders. Primary cancer site also impacted the occurrence of device-related infection. Receiving oncologic/palliative care (HR = 3.0, P = 0.064), advanced cancer stage (HR = 6.5, P = 0.077) and body surface area above 1.71 m(2) (HR = 3.4, P = 0.029) increased the risk of port system occlusion. Our study indicates that totally implantable port systems yield a higher risk of complications in terminally ill patients. Further investigation should be carefully conducted to compare outcomes of various central venous access devices in patients with advanced cancer and to develop preventive strategies against catheter failure.

  17. Impact of Tricuspid Regurgitation on the Success of Atrioventricular Node Ablation for Rate Control in Patients With Atrial Fibrillation: The Node Blast Study.

    PubMed

    Reddy, Yeruva Madhu; Gunda, Sampath; Vallakati, Ajay; Kanmanthareddy, Arun; Pillarisetti, Jayasree; Atkins, Donita; Bommana, Sudharani; Emert, Martin P; Pimentel, Rhea; Dendi, Raghuveer; Berenbom, Loren D; Lakkireddy, Dhanunjaya

    2015-09-15

    Atrioventricular node (AVN) ablation is an effective treatment for symptomatic patients with atrial arrhythmias who are refractory to rhythm and rate control strategies where optimal ventricular rate control is desired. There are limited data on the predictors of failure of AVN ablation. Our objective was to identify the predictors of failure of AVN ablation. This is an observational single-center study of consecutive patients who underwent AVN ablation in a large academic center. Baseline characteristics, procedural variables, and outcomes of AVN ablation were collected. AVN "ablation failure" was defined as resumption of AVN conduction resulting in recurrence of either rapid ventricular response or suboptimal biventricular pacing. A total of 247 patients drug refractory AF who underwent AVN ablation at our center with a mean age of 71 ± 12 years with 46% being males were included. Ablation failure was seen in 11 (4.5%) patients. There were no statistical differences between patients with "ablation failure" versus "ablation success" in any of the baseline clinical variables. Patients with moderate-to-severe tricuspid regurgitation (TR) were much more likely to have ablation failure than those with ablation success (8 [73%] vs 65 [27%]; p = 0.003). All 11 patients with ablation failure had a successful redo procedure, 9 with right and 2 with the left sided approach. On multivariate analysis, presence of moderate-to-severe TR was found to be the only predictor of failure of AVN ablation (odds ratio 9.1, confidence interval 1.99 to 42.22, p = 0.004). In conclusion, moderate-to-severe TR is a strong and independent predictor of failure of AVN ablation. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Serum Uromodulin: A Biomarker of Long-Term Kidney Allograft Failure.

    PubMed

    Bostom, Andrew; Steubl, Dominik; Garimella, Pranav S; Franceschini, Nora; Roberts, Mary B; Pasch, Andreas; Ix, Joachim H; Tuttle, Katherine R; Ivanova, Anastasia; Shireman, Theresa; Kim, S Joseph; Gohh, Reginald; Weiner, Daniel E; Levey, Andrew S; Hsu, Chi-Yuan; Kusek, John W; Eaton, Charles B

    2018-01-01

    Uromodulin is a kidney-derived glycoprotein and putative tubular function index. Lower serum uromodulin was recently associated with increased risk for kidney allograft failure in a preliminary, longitudinal single-center -European study involving 91 kidney transplant recipients (KTRs). The Folic Acid for Vascular Outcome Reduction in Transplantation (FAVORIT) trial is a completed, large, multiethnic controlled clinical trial cohort, which studied chronic, stable KTRs. We conducted a case cohort analysis using a randomly selected subset of patients (random subcohort, n = 433), and all individuals who developed kidney allograft failure (cases, n = 226) during follow-up. Serum uromodulin was determined in this total of n = 613 FAVORIT trial participants at randomization. Death-censored kidney allograft failure was the study outcome. The 226 kidney allograft failures occurred during a median surveillance of 3.2 years. Unadjusted, weighted Cox proportional hazards modeling revealed that lower serum uromodulin, tertile 1 vs. tertile 3, was associated with a threefold greater risk for kidney allograft failure (hazards ratio [HR], 95% CI 3.20 [2.05-5.01]). This association was attenuated but persisted at twofold greater risk for allograft failure, after adjustment for age, sex, smoking, allograft type and vintage, prevalent diabetes mellitus and cardiovascular disease (CVD), total/high-density lipoprotein cholesterol ratio, systolic blood pressure, estimated glomerular filtration rate, and natural log urinary albumin/creatinine: HR 2.00, 95% CI (1.06-3.77). Lower serum uromodulin, a possible indicator of less well-preserved renal tubular function, remained associated with greater risk for kidney allograft failure, after adjustment for major, established clinical kidney allograft failure and CVD risk factors, in a large, multiethnic cohort of long-term, stable KTRs. © 2018 S. Karger AG, Basel.

  19. Drug target identification using network analysis: Taking active components in Sini decoction as an example

    NASA Astrophysics Data System (ADS)

    Chen, Si; Jiang, Hailong; Cao, Yan; Wang, Yun; Hu, Ziheng; Zhu, Zhenyu; Chai, Yifeng

    2016-04-01

    Identifying the molecular targets for the beneficial effects of active small-molecule compounds simultaneously is an important and currently unmet challenge. In this study, we firstly proposed network analysis by integrating data from network pharmacology and metabolomics to identify targets of active components in sini decoction (SND) simultaneously against heart failure. To begin with, 48 potential active components in SND against heart failure were predicted by serum pharmacochemistry, text mining and similarity match. Then, we employed network pharmacology including text mining and molecular docking to identify the potential targets of these components. The key enriched processes, pathways and related diseases of these target proteins were analyzed by STRING database. At last, network analysis was conducted to identify most possible targets of components in SND. Among the 25 targets predicted by network analysis, tumor necrosis factor α (TNF-α) was firstly experimentally validated in molecular and cellular level. Results indicated that hypaconitine, mesaconitine, higenamine and quercetin in SND can directly bind to TNF-α, reduce the TNF-α-mediated cytotoxicity on L929 cells and exert anti-myocardial cell apoptosis effects. We envisage that network analysis will also be useful in target identification of a bioactive compound.

  20. Drug target identification using network analysis: Taking active components in Sini decoction as an example

    PubMed Central

    Chen, Si; Jiang, Hailong; Cao, Yan; Wang, Yun; Hu, Ziheng; Zhu, Zhenyu; Chai, Yifeng

    2016-01-01

    Identifying the molecular targets for the beneficial effects of active small-molecule compounds simultaneously is an important and currently unmet challenge. In this study, we firstly proposed network analysis by integrating data from network pharmacology and metabolomics to identify targets of active components in sini decoction (SND) simultaneously against heart failure. To begin with, 48 potential active components in SND against heart failure were predicted by serum pharmacochemistry, text mining and similarity match. Then, we employed network pharmacology including text mining and molecular docking to identify the potential targets of these components. The key enriched processes, pathways and related diseases of these target proteins were analyzed by STRING database. At last, network analysis was conducted to identify most possible targets of components in SND. Among the 25 targets predicted by network analysis, tumor necrosis factor α (TNF-α) was firstly experimentally validated in molecular and cellular level. Results indicated that hypaconitine, mesaconitine, higenamine and quercetin in SND can directly bind to TNF-α, reduce the TNF-α-mediated cytotoxicity on L929 cells and exert anti-myocardial cell apoptosis effects. We envisage that network analysis will also be useful in target identification of a bioactive compound. PMID:27095146

  1. Cyclic fatigue analysis of rocket thrust chambers. Volume 1: OFHC copper chamber low cycle fatigue

    NASA Technical Reports Server (NTRS)

    Miller, R. W.

    1974-01-01

    A three-dimensional finite element elasto-plastic strain analysis was performed for the throat section of a regeneratively cooled rocket combustion chamber. The analysis employed the RETSCP finite element computer program. The analysis included thermal and pressure loads, and the effects of temperature dependent material properties, to determine the strain range corresponding to the chamber operating cycle. The analysis was performed for chamber configuration and operating conditions corresponding to a hydrogen-oxygen combustion chamber which was fatigue tested to failure. The computed strain range at typical chamber operating conditions was used in conjunction with oxygen-free, high-conductivity (OHFC) copper isothermal fatigue test data to predict chamber low-cycle fatigue life.

  2. Experimental study on the connection property of full-scale composite member

    NASA Astrophysics Data System (ADS)

    Panpan, Cao; Qing, Sun

    2018-01-01

    The excellent properties of composite result in its increasingly application in electric power construction, however there are less experimental studies on full-scale composite member connection property. Full-scale experiments of the connection property between E-glass fiber/epoxy reinforced polymer member and steel casing in practical engineering have been conducted. Based on the axial compression test of the designed specimens, the failure process and failure characteristics were observed, the load-displacement curves and strain distribution of the specimens were obtained. The finite element analysis was used to get the tensile connection strength of the component. The connection property of the components was analyzed to provide basis of the casing connection of GFRP application in practical engineering.

  3. Improving the durability of the optical fiber sensor based on strain transfer analysis

    NASA Astrophysics Data System (ADS)

    Wang, Huaping; Jiang, Lizhong; Xiang, Ping

    2018-05-01

    To realize the reliable and long-term strain detection, the durability of optical fiber sensors has attracted more and more attention. The packaging technique has been considered as an effective method, which can enhance the survival ratios of optical fiber sensors to resist the harsh construction and service environment in civil engineering. To monitor the internal strain of structures, the embedded installation is adopted. Due to the different material properties between host material and the protective layer, the monitored structure embedded with sensors can be regarded as a typical model containing inclusions. Interfacial characteristic between the sensor and host material exists obviously, and the contacted interface is prone to debonding failure induced by the large interfacial shear stress. To recognize the local interfacial debonding damage and extend the effective life cycle of the embedded sensor, strain transfer analysis of a general three-layered sensing model is conducted to investigate the failure mechanism. The perturbation of the embedded sensor on the local strain field of host material is discussed. Based on the theoretical analysis, the distribution of the interfacial shear stress along the sensing length is characterized and adopted for the diagnosis of local interfacial debonding, and the sensitive parameters influencing the interfacial shear stress are also investigated. The research in this paper explores the interfacial debonding failure mechanism of embedded sensors based on the strain transfer analysis and provides theoretical basis for enhancing the interfacial bonding properties and improving the durability of embedded optical fiber sensors.

  4. [Application of root cause analysis in healthcare].

    PubMed

    Hsu, Tsung-Fu

    2007-12-01

    The main purpose of this study was to explore various aspects of root cause analysis (RCA), including its definition, rationale concept, main objective, implementation procedures, most common analysis methodology (fault tree analysis, FTA), and advantages and methodologic limitations in regard to healthcare. Several adverse events that occurred at a certain hospital were also analyzed by the author using FTA as part of this study. RCA is a process employed to identify basic and contributing causal factors underlying performance variations associated with adverse events. The rationale concept of RCA offers a systemic approach to improving patient safety that does not assign blame or liability to individuals. The four-step process involved in conducting an RCA includes: RCA preparation, proximate cause identification, root cause identification, and recommendation generation and implementation. FTA is a logical, structured process that can help identify potential causes of system failure before actual failures occur. Some advantages and significant methodologic limitations of RCA were discussed. Finally, we emphasized that errors stem principally from faults attributable to system design, practice guidelines, work conditions, and other human factors, which induce health professionals to make negligence or mistakes with regard to healthcare. We must explore the root causes of medical errors to eliminate potential RCA system failure factors. Also, a systemic approach is needed to resolve medical errors and move beyond a current culture centered on assigning fault to individuals. In constructing a real environment of patient-centered safety healthcare, we can help encourage clients to accept state-of-the-art healthcare services.

  5. Evaluation of Acoustic Emission NDE of Kevlar Composite Over Wrapped Pressure Vessels

    NASA Technical Reports Server (NTRS)

    Horne, Michael R.; Madaras, Eric I.

    2008-01-01

    Pressurization and failure tests of small Kevlar/epoxy COPV bottles were conducted during 2006 and 2007 by Texas Research Institute Austin, Inc., at TRI facilities. This is a report of the analysis of the Acoustic Emission (AE) data collected during those tests. Results of some of the tests indicate a possibility that AE can be used to track the stress-rupture degradation of COPV vessels.

  6. Defense Standardization Program Journal. October/December 2011

    DTIC Science & Technology

    2011-12-01

    34 tends to yield a negative con - notation, because some people may believe that a mistake or failure has occurred. But, in fact, lessons learned are...to further refine processes or pro - cedures. In order for coalition partners and al- lies to meet the demands of a changing global environment...other things, those stakeholders conducted a SWOT (strengths, weak- nesses, opportunities, threats) analysis to help identify practicable options. The

  7. Evaluation program for secondary spacecraft cells

    NASA Technical Reports Server (NTRS)

    Christy, D. E.; Harkness, J. D.

    1973-01-01

    A life cycle test of secondary electric batteries for spacecraft applications was conducted. A sample number of nickel cadmium batteries were subjected to general performance tests to determine the limit of their actual capabilities. Weaknesses discovered in cell design are reported and aid in research and development efforts toward improving the reliability of spacecraft batteries. A statistical analysis of the life cycle prediction and cause of failure versus test conditions is provided.

  8. Reliability and Failure Modes of Solid-State Lighting Electrical Drivers Subjected to Accelerated Aging

    DOE PAGES

    Lall, Pradeep; Sakalaukus, Peter; Davis, Lynn

    2015-02-19

    An investigation of an off-the-shelf solid-state lighting device with the primary focus on the accompanied light-emitting diode (LED) electrical driver (ED) has been conducted. A set of 10 EDs were exposed to temperature humidity life testing of 85% RH and 85 C (85/85) without an electrical bias per the JEDEC standard JESD22-A101C in order to accelerate the ingress of moisture into the aluminum electrolytic capacitor (AEC) and the EDs in order to assess the reliability of the LED drivers for harsh environment applications. The capacitance and equivalent series resistance for each AEC inside the ED were measured using a handheldmore » LCR meter as possible leading indications of failure. The photometric quantities of a single pristine light engine were monitored in order to investigate the interaction between the light engine and the EDs. These parameters were used in assessing the overall reliability of the EDs. In addition, a comparative analysis has been conducted between the 85/85 accelerated test data and a previously published high-temperature storage life accelerated test of 135°C. The results of the 85/85 acceleration test and the comparative analysis are presented in this paper.« less

  9. Bridging Human Reliability Analysis and Psychology, Part 2: A Cognitive Framework to Support HRA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    April M. Whaley; Stacey M. L. Hendrickson; Ronald L. Boring

    This is the second of two papers that discuss the literature review conducted as part of the U.S. Nuclear Regulatory Commission (NRC) effort to develop a hybrid human reliability analysis (HRA) method in response to Staff Requirements Memorandum (SRM) SRM-M061020. This review was conducted with the goal of strengthening the technical basis within psychology, cognitive science and human factors for the hybrid HRA method being proposed. An overview of the literature review approach and high-level structure is provided in the first paper, whereas this paper presents the results of the review. The psychological literature review encompassed research spanning the entiretymore » of human cognition and performance, and consequently produced an extensive list of psychological processes, mechanisms, and factors that contribute to human performance. To make sense of this large amount of information, the results of the literature review were organized into a cognitive framework that identifies causes of failure of macrocognition in humans, and connects those proximate causes to psychological mechanisms and performance influencing factors (PIFs) that can lead to the failure. This cognitive framework can serve as a tool to inform HRA. Beyond this, however, the cognitive framework has the potential to also support addressing human performance issues identified in Human Factors applications.« less

  10. Increasing value and reducing waste in research design, conduct, and analysis.

    PubMed

    Ioannidis, John P A; Greenland, Sander; Hlatky, Mark A; Khoury, Muin J; Macleod, Malcolm R; Moher, David; Schulz, Kenneth F; Tibshirani, Robert

    2014-01-11

    Correctable weaknesses in the design, conduct, and analysis of biomedical and public health research studies can produce misleading results and waste valuable resources. Small effects can be difficult to distinguish from bias introduced by study design and analyses. An absence of detailed written protocols and poor documentation of research is common. Information obtained might not be useful or important, and statistical precision or power is often too low or used in a misleading way. Insufficient consideration might be given to both previous and continuing studies. Arbitrary choice of analyses and an overemphasis on random extremes might affect the reported findings. Several problems relate to the research workforce, including failure to involve experienced statisticians and methodologists, failure to train clinical researchers and laboratory scientists in research methods and design, and the involvement of stakeholders with conflicts of interest. Inadequate emphasis is placed on recording of research decisions and on reproducibility of research. Finally, reward systems incentivise quantity more than quality, and novelty more than reliability. We propose potential solutions for these problems, including improvements in protocols and documentation, consideration of evidence from studies in progress, standardisation of research efforts, optimisation and training of an experienced and non-conflicted scientific workforce, and reconsideration of scientific reward systems. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. Ultrasound guided placement of the distal catheter in paediatric ventriculoatrial shunts-an appraisal of efficacy and complications.

    PubMed

    Clark, David J; Chakraborty, Aabir; Roebuck, Derek J; Thompson, Dominic N P

    2016-07-01

    Ventriculoatrial (VA) shunts are commonly used as a second-line treatment of hydrocephalus when the peritoneum is an unsuitable site for the distal catheter. Many centres now utilise ultrasound and interventional radiology techniques to aid placement of the distal catheter. The purpose of this study was to conduct a contemporary audit of VA shunting in children using interventional radiology techniques for placement of the distal catheter. A retrospective analysis of all patients who had VA shunts inserted between June 2000 and June 2010 was conducted using a prospectively updated surgical database and case notes review. Ninety-four VA shunts were inserted in 38 patients. Thirty-seven patients had been treated initially with ventriculoperitoneal (VP) shunts. Twenty-two patients required at least 1 shunt revision (58 %). The 6-month, 1- and 2-year shunt survival rates were 53, 43 and 27 %, respectively. Blockage was the commonest reason for shunt failure (68 %). The site of failure was proximal (ventricular catheter +/- valve) in 32 % and distal (atrial catheter) in 21 % of cases. The overall infection rate was 6 % per procedure and 11 % per patient. There were 7 deaths, of which 3 were shunt related. VA shunting provides a viable second-line option for shunt placement in complex hydrocephalus. The causes of shunt failure (blockage, infection and equipment failure) are similar to VP shunting though shunt survival rates are inferior to VP shunts. Ultrasound guided VA shunt placement provides a relatively safe, second-line alternative to the placement of a ventriculoperitoneal shunt when this route is unsuitable.

  12. A review of wiring system safety in space power systems

    NASA Technical Reports Server (NTRS)

    Stavnes, Mark W.; Hammoud, Ahmad N.

    1993-01-01

    Wiring system failures have resulted from arc propagation in the wiring harnesses of current aerospace vehicles. These failures occur when the insulation becomes conductive upon the initiation of an arc. In some cases, the conductive path of the carbon arc track displays a high enough resistance such that the current is limited, and therefore may be difficult to detect using conventional circuit protection. Often, such wiring failures are not simply the result of insulation failure, but are due to a combination of wiring system factors. Inadequate circuit protection, unforgiving system designs, and careless maintenance procedures can contribute to a wiring system failure. This paper approaches the problem with respect to the overall wiring system, in order to determine what steps can be taken to improve the reliability, maintainability, and safety of space power systems. Power system technologies, system designs, and maintenance procedures which have led to past wiring system failures will be discussed. New technologies, design processes, and management techniques which may lead to improved wiring system safety will be introduced.

  13. An analysis of policy success and failure in formal evaluations of Australia's national mental health strategy (1992-2012).

    PubMed

    Grace, Francesca C; Meurk, Carla S; Head, Brian W; Hall, Wayne D; Harris, Meredith G; Whiteford, Harvey A

    2017-05-30

    Heightened fiscal constraints, increases in the chronic disease burden and in consumer expectations are among several factors contributing to the global interest in evidence-informed health policy. The present article builds on previous work that explored how the Australian Federal Government applied five instruments of policy, or policy levers, to implement a series of reforms under the Australian National Mental Health Strategy (NMHS). The present article draws on theoretical insights from political science to analyse the relative successes and failures of these levers, as portrayed in formal government evaluations of the NMHS. Documentary analysis of six evaluation documents corresponding to three National Mental Health Plans was undertaken. Both the content and approach of these government-funded, independently conducted evaluations were appraised. An overall improvement was apparent in the development and application of policy levers over time. However, this finding should be interpreted with caution due to variations in evaluation approach according to Plan and policy lever. Tabulated summaries of the success and failure of each policy initiative, ordered by lever type, are provided to establish a resource that could be consulted for future policy-making. This analysis highlights the complexities of health service reform and underscores the limitations of narrowly focused empirical approaches. A theoretical framework is provided that could inform the evaluation and targeted selection of appropriate policy levers in mental health.

  14. Risk management for outsourcing biomedical waste disposal – Using the failure mode and effects analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liao, Ching-Jong; Ho, Chao Chung, E-mail: ho919@pchome.com.tw

    Highlights: • This study is based on a real case in hospital in Taiwan. • We use Failure Mode and Effects Analysis (FMEA) as the evaluation method. • We successfully identify the evaluation factors of bio-medical waste disposal risk. - Abstract: Using the failure mode and effects analysis, this study examined biomedical waste companies through risk assessment. Moreover, it evaluated the supervisors of biomedical waste units in hospitals, and factors relating to the outsourcing risk assessment of biomedical waste in hospitals by referring to waste disposal acts. An expert questionnaire survey was conducted on the personnel involved in waste disposalmore » units in hospitals, in order to identify important factors relating to the outsourcing risk of biomedical waste in hospitals. This study calculated the risk priority number (RPN) and selected items with an RPN value higher than 80 for improvement. These items included “availability of freezing devices”, “availability of containers for sharp items”, “disposal frequency”, “disposal volume”, “disposal method”, “vehicles meeting the regulations”, and “declaration of three lists”. This study also aimed to identify important selection factors of biomedical waste disposal companies by hospitals in terms of risk. These findings can serve as references for hospitals in the selection of outsourcing companies for biomedical waste disposal.« less

  15. Aerobic Interval vs. Continuous Training in Patients with Coronary Artery Disease or Heart Failure: An Updated Systematic Review and Meta-Analysis with a Focus on Secondary Outcomes.

    PubMed

    Pattyn, Nele; Beulque, Randy; Cornelissen, Véronique

    2018-05-01

    In a previous meta-analysis including nine trials comparing aerobic interval training with aerobic continuous training in patients with coronary artery disease, we found a significant difference in peak oxygen uptake favoring aerobic interval training. The objective of this study was to (1) update the original meta-analysis focussing on peak oxygen uptake and (2) evaluate the effect on secondary outcomes. We conducted a systematic review with a meta-analysis by searching PubMed and SPORTDiscus databases up to March 2017. We included randomized trials comparing aerobic interval training and aerobic continuous training in patients with coronary artery disease or chronic heart failure. The primary outcome was change in peak oxygen uptake. Secondary outcomes included cardiorespiratory parameters, cardiovascular risk factors, cardiac and vascular function, and quality of life. Twenty-four papers were identified (n = 1080; mean age 60.7 ± 10.7 years). Aerobic interval training resulted in a higher increase in peak oxygen uptake compared with aerobic continuous training in all patients (1.40 mL/kg/min; p < 0.001), and in the subgroups of patients with coronary artery disease (1.25 mL/kg/min; p = 0.001) and patients with chronic heart failure with reduced ejection fraction (1.46 mL/kg/min; p = 0.03). Moreover, a larger increase of the first ventilatory threshold and peak heart rate was observed after aerobic interval training in all patients. Other cardiorespiratory parameters, cardiovascular risk factors, and quality of life were equally affected. This meta-analysis adds further evidence to the clinically significant larger increase in peak oxygen uptake following aerobic interval training vs. aerobic continuous training in patients with coronary artery disease and chronic heart failure. More well-designed randomized controlled trials are needed to establish the safety of aerobic interval training and the sustainability of the training response over longer periods.

  16. Insight into the hydraulics and resilience of Ponderosa pine seedlings using a mechanistic ecohydrologic model

    NASA Astrophysics Data System (ADS)

    Maneta, M. P.; Simeone, C.; Dobrowski, S.; Holden, Z.; Sapes, G.; Sala, A.; Begueria, S.

    2017-12-01

    In semiarid regions, drought-induced seedling mortality is considered to be caused by failure in the tree hydraulic column. Understanding the mechanisms that cause hydraulic failure and death in seedlings is important, among other things, to diagnose where some tree species may fail to regenerate, triggering demographic imbalances in the forest that could result in climate-driven shifts of tree species. Ponderosa pine is a common lower tree line species in the western US. Seedlings of ponderosa pine are often subject to low soil water potentials, which require lower water potentials in the xylem and leaves to maintain the negative pressure gradient that drives water upward. The resilience of the hydraulic column to hydraulic tension is species dependent, but from greenhouse experiments, we have identified general tension thresholds beyond which loss of xylem conductivity becomes critical, and mortality in Ponderosa pine seedlings start to occur. We describe this hydraulic behavior of plants using a mechanistic soil-vegetation-atmosphere transfer model. Before we use this models to understand water-stress induced seedling mortality at the landscape scale, we perform a modeling analysis of the dynamics of soil moisture, transpiration, leaf water potential and loss of plant water conductivity using detailed data from our green house experiments. The analysis is done using a spatially distributed model that simulates water fluxes, energy exchanges and water potentials in the soil-vegetation-atmosphere continuum. Plant hydraulic and physiological parameters of this model were calibrated using Monte Carlo methods against information on soil moisture, soil hydraulic potential, transpiration, leaf water potential and percent loss of conductivity in the xylem. This analysis permits us to construct a full portrait of the parameter space for Ponderosa pine seedling and generate posterior predictive distributions of tree response to understand the sensitivity of transpiration, hydraulic tension in the plant, and percent loss of conductivity to environmental stresses.

  17. User-Defined Material Model for Progressive Failure Analysis

    NASA Technical Reports Server (NTRS)

    Knight, Norman F. Jr.; Reeder, James R. (Technical Monitor)

    2006-01-01

    An overview of different types of composite material system architectures and a brief review of progressive failure material modeling methods used for structural analysis including failure initiation and material degradation are presented. Different failure initiation criteria and material degradation models are described that define progressive failure formulations. These progressive failure formulations are implemented in a user-defined material model (or UMAT) for use with the ABAQUS/Standard1 nonlinear finite element analysis tool. The failure initiation criteria include the maximum stress criteria, maximum strain criteria, the Tsai-Wu failure polynomial, and the Hashin criteria. The material degradation model is based on the ply-discounting approach where the local material constitutive coefficients are degraded. Applications and extensions of the progressive failure analysis material model address two-dimensional plate and shell finite elements and three-dimensional solid finite elements. Implementation details and use of the UMAT subroutine are described in the present paper. Parametric studies for composite structures are discussed to illustrate the features of the progressive failure modeling methods that have been implemented.

  18. An efficient scan diagnosis methodology according to scan failure mode for yield enhancement

    NASA Astrophysics Data System (ADS)

    Kim, Jung-Tae; Seo, Nam-Sik; Oh, Ghil-Geun; Kim, Dae-Gue; Lee, Kyu-Taek; Choi, Chi-Young; Kim, InSoo; Min, Hyoung Bok

    2008-12-01

    Yield has always been a driving consideration during fabrication of modern semiconductor industry. Statistically, the largest portion of wafer yield loss is defective scan failure. This paper presents efficient failure analysis methods for initial yield ramp up and ongoing product with scan diagnosis. Result of our analysis shows that more than 60% of the scan failure dies fall into the category of shift mode in the very deep submicron (VDSM) devices. However, localization of scan shift mode failure is very difficult in comparison to capture mode failure because it is caused by the malfunction of scan chain. Addressing the biggest challenge, we propose the most suitable analysis method according to scan failure mode (capture / shift) for yield enhancement. In the event of capture failure mode, this paper describes the method that integrates scan diagnosis flow and backside probing technology to obtain more accurate candidates. We also describe several unique techniques, such as bulk back-grinding solution, efficient backside probing and signal analysis method. Lastly, we introduce blocked chain analysis algorithm for efficient analysis of shift failure mode. In this paper, we contribute to enhancement of the yield as a result of the combination of two methods. We confirm the failure candidates with physical failure analysis (PFA) method. The direct feedback of the defective visualization is useful to mass-produce devices in a shorter time. The experimental data on mass products show that our method produces average reduction by 13.7% in defective SCAN & SRAM-BIST failure rates and by 18.2% in wafer yield rates.

  19. Operations analysis (study 2.1). Contingency analysis. [of failure modes anticipated during space shuttle upper stage planning

    NASA Technical Reports Server (NTRS)

    1974-01-01

    Future operational concepts for the space transportation system were studied in terms of space shuttle upper stage failure contingencies possible during deployment, retrieval, or space servicing of automated satellite programs. Problems anticipated during mission planning were isolated using a modified 'fault tree' technique, normally used in safety analyses. A comprehensive space servicing hazard analysis is presented which classifies possible failure modes under the catagories of catastrophic collision, failure to rendezvous and dock, servicing failure, and failure to undock. The failure contingencies defined are to be taken into account during design of the upper stage.

  20. Reduced risk of heart failure with intensified multifactorial intervention in individuals with type 2 diabetes and microalbuminuria: 21 years of follow-up in the randomised Steno-2 study.

    PubMed

    Oellgaard, Jens; Gæde, Peter; Rossing, Peter; Rørth, Rasmus; Køber, Lars; Parving, Hans-Henrik; Pedersen, Oluf

    2018-05-30

    In type 2 diabetes mellitus, heart failure is a frequent, potentially fatal and often forgotten complication. Glucose-lowering agents and adjuvant therapies modify the risk of heart failure. We recently reported that 7.8 years of intensified compared with conventional multifactorial intervention in individuals with type 2 diabetes and microalbuminuria in the Steno-2 study reduced the risk of cardiovascular disease and prolonged life over 21.2 years of follow-up. In this post hoc analysis, we examine the impact of intensified multifactorial intervention on the risk of hospitalisation for heart failure. One hundred and sixty individuals were randomised to conventional or intensified multifactorial intervention, using sealed envelopes. The trial was conducted using the Prospective, Randomised, Open, Blinded Endpoints (PROBE) design. After 7.8 years, all individuals were offered intensified therapy and the study continued as an observational follow-up study for an additional 13.4 years. Heart-failure hospitalisations were adjudicated from patient records by an external expert committee blinded for treatment allocation. Event rates were compared using a Cox regression model adjusted for age and sex. Eighty patients were assigned to each treatment group. Ten patients undergoing intensive therapy vs 24 undergoing conventional therapy were hospitalised for heart failure during follow-up. The HR (95% CI) was 0.30 (0.14, 0.64), p = 0.002 in the intensive-therapy group compared with the conventional-therapy group. Including death in the endpoint did not lead to an alternate overall outcome; HR 0.51 (0.34, 0.76), p = 0.001. In a pooled cohort analysis, an increase in plasma N-terminal pro-B-type natriuretic peptide (NT-proBNP) during the first two years of the trial was associated with incident heart failure. Intensified, multifactorial intervention for 7.8 years in type 2 diabetic individuals with microalbuminuria reduced the risk of hospitalisation for heart failure by 70% during a total of 21.2 years of observation. ClinicalTrials.gov NCT00320008.

  1. Shuttle Gaseous Hydrogen Venting Risk from Flow Control Valve Failure

    NASA Technical Reports Server (NTRS)

    Drummond, J. Philip; Baurle, Robert A.; Gafney, Richard L.; Norris, Andrew T.; Pellett, Gerald L.; Rock, Kenneth E.

    2009-01-01

    This paper describes a series of studies to assess the potential risk associated with the failure of one of three gaseous hydrogen flow control valves in the orbiter's main propulsion system during the launch of Shuttle Endeavour (STS-126) in November 2008. The studies focused on critical issues associated with the possibility of combustion resulting from release of gaseous hydrogen from the external tank into the atmosphere during assent. The Shuttle Program currently assumes hydrogen venting from the external tank will result in a critical failure. The current effort was conducted to increase understanding of the risk associated with venting hydrogen given the flow control valve failure scenarios being considered in the Integrated In-Flight Anomaly Investigation being conducted by NASA.

  2. A Nationwide Assessment of the Association of Smoking Bans and Cigarette Taxes With Hospitalizations for Acute Myocardial Infarction, Heart Failure, and Pneumonia

    PubMed Central

    Ho, Vivian; Ross, Joseph S.; Steiner, Claudia A.; Mandawat, Aditya; Short, Marah; Ku-Goto, Meei-Hsiang; Krumholz, Harlan M.

    2016-01-01

    Multiple studies claim that public place smoking bans are associated with reductions in smoking-related hospitalization rates. No national study using complete hospitalization counts by area that accounts for contemporaneous controls including state cigarette taxes has been conducted. We examine the association between county-level smoking-related hospitalization rates and comprehensive smoking bans in 28 states from 2001 to 2008. Differences-in-differences analysis measures changes in hospitalization rates before versus after introducing bans in bars, restaurants, and workplaces, controlling for cigarette taxes, adjusting for local health and provider characteristics. Smoking bans were not associated with acute myocardial infarction or heart failure hospitalizations, but lowered pneumonia hospitalization rates for persons ages 60 to 74 years. Higher cigarette taxes were associated with lower heart failure hospitalizations for all ages and fewer pneumonia hospitalizations for adults aged 60 to 74. Previous studies may have overestimated the relation between smoking bans and hospitalizations and underestimated the effects of cigarette taxes. PMID:27624634

  3. A Nationwide Assessment of the Association of Smoking Bans and Cigarette Taxes With Hospitalizations for Acute Myocardial Infarction, Heart Failure, and Pneumonia.

    PubMed

    Ho, Vivian; Ross, Joseph S; Steiner, Claudia A; Mandawat, Aditya; Short, Marah; Ku-Goto, Meei-Hsiang; Krumholz, Harlan M

    2017-12-01

    Multiple studies claim that public place smoking bans are associated with reductions in smoking-related hospitalization rates. No national study using complete hospitalization counts by area that accounts for contemporaneous controls including state cigarette taxes has been conducted. We examine the association between county-level smoking-related hospitalization rates and comprehensive smoking bans in 28 states from 2001 to 2008. Differences-in-differences analysis measures changes in hospitalization rates before versus after introducing bans in bars, restaurants, and workplaces, controlling for cigarette taxes, adjusting for local health and provider characteristics. Smoking bans were not associated with acute myocardial infarction or heart failure hospitalizations, but lowered pneumonia hospitalization rates for persons ages 60 to 74 years. Higher cigarette taxes were associated with lower heart failure hospitalizations for all ages and fewer pneumonia hospitalizations for adults aged 60 to 74. Previous studies may have overestimated the relation between smoking bans and hospitalizations and underestimated the effects of cigarette taxes.

  4. Role of failure-mechanism identification in accelerated testing

    NASA Technical Reports Server (NTRS)

    Hu, J. M.; Barker, D.; Dasgupta, A.; Arora, A.

    1993-01-01

    Accelerated life testing techniques provide a short-cut method to investigate the reliability of electronic devices with respect to certain dominant failure mechanisms that occur under normal operating conditions. However, accelerated tests have often been conducted without knowledge of the failure mechanisms and without ensuring that the test accelerated the same mechanism as that observed under normal operating conditions. This paper summarizes common failure mechanisms in electronic devices and packages and investigates possible failure mechanism shifting during accelerated testing.

  5. Hypertension, Obesity, Diabetes, and Heart Failure-Free Survival: The Cardiovascular Disease Lifetime Risk Pooling Project.

    PubMed

    Ahmad, Faraz S; Ning, Hongyan; Rich, Jonathan D; Yancy, Clyde W; Lloyd-Jones, Donald M; Wilkins, John T

    2016-12-01

    This study was designed to quantify the relationship between the absence of heart failure risk factors in middle age and incident heart failure, heart failure-free survival, and overall survival. Quantification of years lived free from heart failure in the context of risk factor burden in mid-life may improve risk communication and prevention efforts. We conducted a pooled, individual-level analysis sampling from communities across the United States as part of 4 cohort studies: the Framingham Heart, Framingham Offspring, Chicago Heart Association Detection Project in Industry, and ARIC (Atherosclerosis Risk In Communities) studies. Participants with and without hypertension (blood pressure ≥140/90 mm Hg or treatment), obesity (body mass index ≥30 kg/m 2 ), or diabetes (fasting glucose ≥126 mg/dl or treatment), and combinations of these factors, at index ages of 45 years and 55 years through 95 years. Competing risk-adjusted Cox models, a modified Kaplan-Meier estimator, and Irwin's restricted mean were used to estimate the association between the absence of risk factors at mid-life and incident heart failure, heart failure-free survival, and overall survival. For participants at age 45 years, over 516,537 person-years of follow-up, 1,677 incident heart failure events occurred. Men and women with no risk factors, compared to those with all 3, had 73% to 85% lower risks of incident heart failure. Men and women without hypertension, obesity, or diabetes at age 45 years lived on average 34.7 years and 38.0 years without incident heart failure, and they lived on average an additional 3 years to 15 years longer free of heart failure than those with 1, 2, or 3 risk factors. Similar trends were seen when stratified by race and at index age 55 years. Prevention of hypertension, obesity, and diabetes by ages 45 years and 55 years may substantially prolong heart failure-free survival, decrease heart failure-related morbidity, and reduce the public health impact of heart failure. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  6. Model-dependent effects of the gap junction conduction-enhancing antiarrhythmic peptide rotigaptide (ZP123) on experimental atrial fibrillation in dogs.

    PubMed

    Shiroshita-Takeshita, Akiko; Sakabe, Masao; Haugan, Ketil; Hennan, James K; Nattel, Stanley

    2007-01-23

    Abnormal intercellular communication caused by connexin dysfunction may be involved in atrial fibrillation (AF). The present study assessed the effect of the gap junctional conduction-enhancing peptide rotigaptide on AF maintenance in substrates that result from congestive heart failure induced by 2-week ventricular tachypacing (240 bpm), atrial tachypacing (ATP; 400 bpm for 3 to 6 weeks), and isolated atrial myocardial ischemia. Electrophysiological study and epicardial mapping were performed before and after rotigaptide administration in dogs with ATP and congestive heart failure, as well as in similarly instrumented sham dogs that were not tachypaced. For atrial myocardial ischemia, dogs administered rotigaptide before myocardial ischemia were compared with no-drug myocardial ischemia controls. ATP significantly shortened the atrial effective refractory period (P=0.003) and increased AF duration (P=0.008), with AF lasting >3 hours in all 6-week ATP animals. Rotigaptide increased conduction velocity in ATP dogs slightly but significantly (P=0.04) and did not affect the effective refractory period, AF duration, or atrial vulnerability. In dogs with congestive heart failure, rotigaptide also slightly increased conduction velocity (P=0.046) but failed to prevent AF promotion. Rotigaptide had no statistically significant effects in sham dogs. Myocardial ischemia alone increased AF duration and impaired conduction (based on conduction velocity across the ischemic border and indices of conduction heterogeneity). Rotigaptide prevented myocardial ischemia-induced conduction slowing and AF duration increases. Rotigaptide improves conduction in various AF models but suppresses AF only for the acute ischemia substrate. These results define the atrial antiarrhythmic profile of a mechanistically novel antiarrhythmic drug and suggest that gap junction dysfunction may be more important in ischemic AF than in ATP remodeling or congestive heart failure substrates.

  7. Intermittent versus continuous exercise training in chronic heart failure: a meta-analysis.

    PubMed

    Smart, Neil A; Dieberg, Gudrun; Giallauria, Francesco

    2013-06-20

    We conducted a meta-analysis of randomized, controlled trials of combined strength and intermittent aerobic training, intermittent aerobic training only and continuous exercise training in heart failure patients. A systematic search was conducted of Medline (Ovid) (1950-September 2011), Embase.com (1974-September 2011), Cochrane Central Register of Controlled Trials and CINAHL (1981-September 19 2011). The search strategy included a mix of MeSH and free text terms for the key concepts heart failure, exercise training, interval training and intermittent exercise training. The included studies contained an aggregate of 446 patients, 212 completed intermittent exercise training, 66 only continuous exercise training, 59 completed combined intermittent and strength training and 109 sedentary controls. Weighted mean difference (MD) in Peak VO2 was 1.04mlkg(-1)min(-1) and (95% C.I.) was 0.42-1.66 (p=0.0009) in intermittent versus continuous exercise training respectively. Weighted mean difference in Peak VO2 was -1.10mlkg(-1)min(-1) (95% C.I.) was -1.83-0.37 p=0.003 for intermittent only versus intermittent and strength (combined) training respectively. In studies reporting VE/VCO2 for intermittent versus control groups, MD was -1.50 [(95% C.I. -2.64, -0.37), p=0.01] and for intermittent versus continuous exercise training MD was -1.35 [(95% C.I. -2.15, -0.55), p=0.001]. Change in peak VO2 was positively correlated with weekly exercise energy expenditure for intermittent exercise groups (r=0.48, p=0.05). Combined strength and intermittent exercise appears superior for peak VO2 changes when compared to intermittent exercise of similar exercise energy expenditure. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  8. Pathogenic and Genotypic Characterization of a Japanese Encephalitis Virus Isolate Associated with Reproductive Failure in an Indian Pig Herd

    PubMed Central

    Desingu, P. A.; Ray, Pradeep K.; Patel, B. H. M.; Singh, R.; Singh, R. K.; Saikumar, G

    2016-01-01

    Background India is endemic to Japanese encephalitis virus (JEV) and recurrent outbreaks occur mainly in rice growing areas. Pigs are considered to be the amplifying host for JEV and infection in gestating pigs results in reproductive failure. Most studies conducted on JEV infection in Indian pigs have been serological surveys and very little is known about JEV genotypes circulating in pigs. So the potential risk posed by pigs in JEV transmission and the genetic relationship between viruses circulating in pigs, mosquitoes and humans is poorly understood. Methodology/Principal Findings This study was conducted in pigs with a history of reproductive failure characterized by stillborn piglets with neuropathological lesions. Japanese encephalitis (JE) suspected brain specimens inoculated intracerebrally into mice and Vero cells resulted in successful isolation of JEV/SW/IVRI/395A/2014. Clinicopathological observations in infected mice, demonstration of JEV antigen in brain, and analysis of the envelope protein identified the swine isolate as being neurovirulent. Phylogenetic analysis based on prM and E gene sequences showed that it belonged to genotype III. This swine isolate was closely related to JEV associated with the 2005 outbreak in India and JaoArS982 from Japan. Phylogenetic analysis of JEV strains collected between 1956 and 2014 in India categorized the GIII viruses into different clades blurring their spatial distribution, which has been discernible in the previous century. Conclusions/Significance Isolation of JEV from stillborn piglets and its close genetic relationship with viruses detected at least three decades ago in humans and mosquitoes in Japan suggests that the virus may have been circulating among Indian pigs for several decades. The close similarity between the present swine isolate and those detected in humans affected in the 2005 outbreak in Uttar Pradesh, India, suggests the need for more intensive surveillance of pigs and implementation of suitable strategies to control JE in India. PMID:26895440

  9. Use of failure mode and effects analysis for proactive identification of communication and handoff failures from organ procurement to transplantation.

    PubMed

    Steinberger, Dina M; Douglas, Stephen V; Kirschbaum, Mark S

    2009-09-01

    A multidisciplinary team from the University of Wisconsin Hospital and Clinics transplant program used failure mode and effects analysis to proactively examine opportunities for communication and handoff failures across the continuum of care from organ procurement to transplantation. The team performed a modified failure mode and effects analysis that isolated the multiple linked, serial, and complex information exchanges occurring during the transplantation of one solid organ. Failure mode and effects analysis proved effective for engaging a diverse group of persons who had an investment in the outcome in analysis and discussion of opportunities to improve the system's resilience for avoiding errors during a time-pressured and complex process.

  10. Failure Mode, Effects, and Criticality Analysis (FMECA)

    DTIC Science & Technology

    1993-04-01

    Preliminary Failure Modes, Effects and Criticality Analysis (FMECA) of the Brayton Isotope Power System Ground Demonstration System, Report No. TID 27301...No. TID/SNA - 3015, Aeroject Nuclear Systems Co., Sacramento, California: 1970. 95. Taylor , J.R. A Formalization of Failure Mode Analysis of Control...Roskilde, Denmark: 1973. 96. Taylor , J.R. A Semi-Automatic Method for Oualitative Failure Mode Analysis. Report No. RISO-M-1707. Available from a

  11. Availability Performance Analysis of Thermal Power Plants

    NASA Astrophysics Data System (ADS)

    Bhangu, Navneet Singh; Singh, Rupinder; Pahuja, G. L.

    2018-03-01

    This case study presents the availability evaluation method of thermal power plants for conducting performance analysis in Indian environment. A generic availability model has been proposed for a maintained system (thermal plants) using reliability block diagrams and fault tree analysis. The availability indices have been evaluated under realistic working environment using inclusion exclusion principle. Four year failure database has been used to compute availability for different combinatory of plant capacity, that is, full working state, reduced capacity or failure state. Availability is found to be very less even at full rated capacity (440 MW) which is not acceptable especially in prevailing energy scenario. One of the probable reason for this may be the difference in the age/health of existing thermal power plants which requires special attention of each unit from case to case basis. The maintenance techniques being used are conventional (50 years old) and improper in context of the modern equipment, which further aggravate the problem of low availability. This study highlights procedure for finding critical plants/units/subsystems and helps in deciding preventive maintenance program.

  12. Accelerated life assessment of coating on the radar structure components in coastal environment.

    PubMed

    Liu, Zhe; Ming, ZhiMao

    2016-07-04

    This paper aimed to build an accelerated life test scheme and carry out quantitative analysis between accelerated life test in the laboratory and actual service for the coating composed of epoxy primer and polyurethane paint on structure components of some kind of radar served in the coastal environment of South China Sea. The accelerated life test scheme was built based on the service environment and failure analysis of the coating. The quantitative analysis between accelerated life test and actual service was conducted by comparing the gloss loss, discoloration, chalking, blistering, cracking and electrochemical impedance spectroscopy of the coating. The main factors leading to the coating failure were ultraviolet radiation, temperature, moisture, salt fog and loads, the accelerated life test included ultraviolet radiation, damp heat, thermal shock, fatigue and salt spray. The quantitative relationship was that one cycle of the accelerated life test was equal to actual service for one year. It was established that one cycle of the accelerated life test was equal to actual service for one year. It provided a precise way to predict actual service life of newly developed coatings for the manufacturer.

  13. Simulation and Failure Analysis of Car Bumper Made of Pineapple Leaf Fiber Reinforced Composite

    NASA Astrophysics Data System (ADS)

    Arbintarso, E. S.; Muslim, M.; Rusianto, T.

    2018-02-01

    The bumper car made of the Pineapple Leaf Fiber Reinforced Composite (PLFRC) is possible to be produced with the advantage of easy to get, and cheap. Pineapple leaf fiber has chosen as a natural fiber, which the maximum of the strength of 368 MPa. The objective of this study was to determine the maximum capability of front car bumpers using Pineapple Leaf Fiber Reinforced Composite materials through the process of simulating stress analysis with Solidworks 2014 software. The aim also to know the distribution of loads that occur on the front car bumper and predict the critical point position on the design of the bumper. The result will use to develop the alternative lightweight, cheap and environmentally friendly materials in general and the development of the use of pineapple fiber for automotive purposes in particular. Simulations and failure analysis have been conducted and showed an increased impact speed in line with increased displacement, strain, and stress that occur on the surface of the bumper. The bumper can withstand collisions at a speed of less than 70 kph.

  14. 30 CFR 285.815 - What must I do if I have facility damage or an equipment failure?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Assessments for Activities Conducted Under SAPs, COPs and GAPs Equipment Failure and Adverse Environmental... damage or failure under § 285.831, MMS may require you to revise your SAP, COP, or GAP to describe how you will address the facility damage or failure as required by § 285.634 (COP), § 285.617 (SAP), § 285...

  15. Comprehension and retrieval of failure cases in airborne observatories

    NASA Technical Reports Server (NTRS)

    Alvarado, Sergio J.; Mock, Kenrick J.

    1995-01-01

    This paper describes research dealing with the computational problem of analyzing and repairing failures of electronic and mechanical systems of telescopes in NASA's airborne observatories, such as KAO (Kuiper Airborne Observatory) and SOFIA (Stratospheric Observatory for Infrared Astronomy). The research has resulted in the development of an experimental system that acquires knowledge of failure analysis from input text, and answers questions regarding failure detection and correction. The system's design builds upon previous work on text comprehension and question answering, including: knowledge representation for conceptual analysis of failure descriptions, strategies for mapping natural language into conceptual representations, case-based reasoning strategies for memory organization and indexing, and strategies for memory search and retrieval. These techniques have been combined into a model that accounts for: (a) how to build a knowledge base of system failures and repair procedures from descriptions that appear in telescope-operators' logbooks and FMEA (failure modes and effects analysis) manuals; and (b) how to use that knowledge base to search and retrieve answers to questions about causes and effects of failures, as well as diagnosis and repair procedures. This model has been implemented in FANSYS (Failure ANalysis SYStem), a prototype text comprehension and question answering program for failure analysis.

  16. Comprehension and retrieval of failure cases in airborne observatories

    NASA Astrophysics Data System (ADS)

    Alvarado, Sergio J.; Mock, Kenrick J.

    1995-05-01

    This paper describes research dealing with the computational problem of analyzing and repairing failures of electronic and mechanical systems of telescopes in NASA's airborne observatories, such as KAO (Kuiper Airborne Observatory) and SOFIA (Stratospheric Observatory for Infrared Astronomy). The research has resulted in the development of an experimental system that acquires knowledge of failure analysis from input text, and answers questions regarding failure detection and correction. The system's design builds upon previous work on text comprehension and question answering, including: knowledge representation for conceptual analysis of failure descriptions, strategies for mapping natural language into conceptual representations, case-based reasoning strategies for memory organization and indexing, and strategies for memory search and retrieval. These techniques have been combined into a model that accounts for: (a) how to build a knowledge base of system failures and repair procedures from descriptions that appear in telescope-operators' logbooks and FMEA (failure modes and effects analysis) manuals; and (b) how to use that knowledge base to search and retrieve answers to questions about causes and effects of failures, as well as diagnosis and repair procedures. This model has been implemented in FANSYS (Failure ANalysis SYStem), a prototype text comprehension and question answering program for failure analysis.

  17. Cost-effectiveness analysis of individualized mycophenolate mofetil dosing in kidney transplant patients in the APOMYGRE trial.

    PubMed

    Rousseau, Annick; Laroche, Marie-Laure; Venisse, Nicolas; Loichot-Roselmac, Cecile; Turcant, Alain; Hoizey, Guillaume; Compagnon, Patricia; Hary, Lionel; Debruyne, Danièle; Saivin, Sylvie; Jacqz-Aigrain, Evelyne; Buchler, Mathias; Villeneuve, Claire; Vergnenègre, Alain; Le Meur, Yannick; Marquet, Pierre

    2010-05-27

    In the prospective, randomized, multicenter APOMYGRE trial conducted in France, concentration-controlled mycophenolate mofetil (MMF) dosing based on mycophenolic acid (MPA) exposure significantly reduced the treatment failure and acute rejection during the first posttransplantation year compared with fixed-dose MMF. This analysis investigated the cost effectiveness of dose individualization. The study included 65 patients per group (intent-to-treat population). Treatment failure (primary efficacy endpoint) was defined as death, graft loss, acute rejection, or MMF discontinuation because of adverse effects. Data on hospitalizations, drugs prescribed, physicians' fees, laboratory expenses, ambulatory visits, and transportation were retrieved. Costs were calculated from the French National Health System perspective. The mean (95% confidence interval) total yearly cost per patient was Euro 47,477 (Euro 43,933; Euro 51,020) in the concentration-controlled group and Euro 46,783 ( Euro 44,152; Euro 49,414) in the fixed-dose group (P=0.7). The observed incremental cost-effectiveness ratio was Euro 3757 per treatment failure (Purchasing Power Parities United States/France: $4129). Hospitalization and drug costs accounted for approximately 50% and 25% of total costs, respectively. The cost for MPA area under the concentration-time curve and dose calculation was Euro 452 per patient, less than 1% of the total cost. In the APOMYGRE trial, therapeutic MPA monitoring using a limited sampling strategy reduced the risk of treatment failure and acute rejection in renal allograft recipients during the first 12 months posttransplantation, at neutral cost.

  18. 14 CFR 417.309 - Flight safety system analysis.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... system anomaly occurring and all of its effects as determined by the single failure point analysis and... termination system. (c) Single failure point. A command control system must undergo an analysis that... fault tree analysis or a failure modes effects and criticality analysis; (2) Identify all possible...

  19. 14 CFR 417.309 - Flight safety system analysis.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... system anomaly occurring and all of its effects as determined by the single failure point analysis and... termination system. (c) Single failure point. A command control system must undergo an analysis that... fault tree analysis or a failure modes effects and criticality analysis; (2) Identify all possible...

  20. 14 CFR 417.309 - Flight safety system analysis.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... system anomaly occurring and all of its effects as determined by the single failure point analysis and... termination system. (c) Single failure point. A command control system must undergo an analysis that... fault tree analysis or a failure modes effects and criticality analysis; (2) Identify all possible...

  1. 14 CFR 417.309 - Flight safety system analysis.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... system anomaly occurring and all of its effects as determined by the single failure point analysis and... termination system. (c) Single failure point. A command control system must undergo an analysis that... fault tree analysis or a failure modes effects and criticality analysis; (2) Identify all possible...

  2. 14 CFR 417.309 - Flight safety system analysis.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... system anomaly occurring and all of its effects as determined by the single failure point analysis and... termination system. (c) Single failure point. A command control system must undergo an analysis that... fault tree analysis or a failure modes effects and criticality analysis; (2) Identify all possible...

  3. Multicollinearity in Regression Analyses Conducted in Epidemiologic Studies

    PubMed Central

    Vatcheva, Kristina P.; Lee, MinJae; McCormick, Joseph B.; Rahbar, Mohammad H.

    2016-01-01

    The adverse impact of ignoring multicollinearity on findings and data interpretation in regression analysis is very well documented in the statistical literature. The failure to identify and report multicollinearity could result in misleading interpretations of the results. A review of epidemiological literature in PubMed from January 2004 to December 2013, illustrated the need for a greater attention to identifying and minimizing the effect of multicollinearity in analysis of data from epidemiologic studies. We used simulated datasets and real life data from the Cameron County Hispanic Cohort to demonstrate the adverse effects of multicollinearity in the regression analysis and encourage researchers to consider the diagnostic for multicollinearity as one of the steps in regression analysis. PMID:27274911

  4. Multicollinearity in Regression Analyses Conducted in Epidemiologic Studies.

    PubMed

    Vatcheva, Kristina P; Lee, MinJae; McCormick, Joseph B; Rahbar, Mohammad H

    2016-04-01

    The adverse impact of ignoring multicollinearity on findings and data interpretation in regression analysis is very well documented in the statistical literature. The failure to identify and report multicollinearity could result in misleading interpretations of the results. A review of epidemiological literature in PubMed from January 2004 to December 2013, illustrated the need for a greater attention to identifying and minimizing the effect of multicollinearity in analysis of data from epidemiologic studies. We used simulated datasets and real life data from the Cameron County Hispanic Cohort to demonstrate the adverse effects of multicollinearity in the regression analysis and encourage researchers to consider the diagnostic for multicollinearity as one of the steps in regression analysis.

  5. Causal Analysis For Occurrence Report OR NA-SS-SNL-2000-2015-0005 Unexpected Type of Failure of Thermal Battery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Forbes, Elizabeth H.

    2015-08-01

    On 6/26/2015 at approximately 1445 in 894/136, a pulse thermal battery (approximately the size of a commercial size C cell) experienced an unexpected failure following an electrical performance test that is routinely conducted on thermal batteries. A dedicated tester for this operation was used and it ran the test until the nominal 28-volt output of the battery had dropped to 5 volts, usually indicative of the battery being spent and safe enough to move. The failure occurred while a test operator was transferring the battery from the testing primary containment box to another primary containment box within the same room;more » initial indications are that the battery experienced an over-pressurization failure which led to the battery's base plate being expelled and the operator receiving a non-recordable injury (bruising to the palm of the hand) from the pressure of the expulsion. The operator was wearing the prescribed PPE (safety glasses and high temperature glove) and was handling the battery appropriately with an open, flat hand. Pictures of the scene are below.« less

  6. Outcome of Heart Failure with Preserved Ejection Fraction: A Multicentre Spanish Registry

    PubMed Central

    Castillo, Juan C; Anguita1, Manuel P; Jiménez, Manuel

    2009-01-01

    Background: Studies on clinical features, treatment and prognosis of patients with congestive heart failure (CHF) and preserved left ventricular ejection fraction (LVEF) are few and their results frequently conflicting. Aims: To investigate the characteristics and long term prognosis of patients with CHF and preserved (≥ 45%) LVEF. Methods and Results: We conducted a prospective multicentre study with 4720 patients attended in 62 heart failure clinics from 1999 to 2003 in Spain (BADAPIC registry). LVEF was preserved in 30% patients. Age, female gender, prevalence of atrial fibrillation, hypertension and non-ischaemic cardiopathy were all significantly greater in patients with preserved LVEF. Mean follow-up was 40±12 months. Mortality and other cardiovascular complication rates during follow up were similar in both groups. On multivariate analysis ejection fraction was not an independent predictor for mortality. Survival at one and five years was similar in both groups (79% and 59% for patients with preserved LVEF and 78% and 57% for those with reduced LVEF, respectively). Conclusions: In the BADAPIC registry, a high percentage of heart failure patients had preserved LVEF. Although clinical differences were seen between groups, morbidity and mortality were similar in both groups. PMID:21037850

  7. Factors associated with maternal death in an intensive care unit

    PubMed Central

    Saintrain, Suzanne Vieira; de Oliveira, Juliana Gomes Ramalho; Saintrain, Maria Vieira de Lima; Bruno, Zenilda Vieira; Borges, Juliana Lima Nogueira; Daher, Elizabeth De Francesco; da Silva Jr, Geraldo Bezerra

    2016-01-01

    Objective To identify factors associated with maternal death in patients admitted to an intensive care unit. Methods A cross-sectional study was conducted in a maternal intensive care unit. All medical records of patients admitted from January 2012 to December 2014 were reviewed. Pregnant and puerperal women were included; those with diagnoses of hydatidiform mole, ectopic pregnancy, or anembryonic pregnancy were excluded, as were patients admitted for non-obstetrical reasons. Death and hospital discharge were the outcomes subjected to comparative analysis. Results A total of 373 patients aged 13 to 45 years were included. The causes for admission to the intensive care unit were hypertensive disorders of pregnancy, followed by heart disease, respiratory failure, and sepsis; complications included acute kidney injury (24.1%), hypotension (15.5%), bleeding (10.2%), and sepsis (6.7%). A total of 28 patients died (7.5%). Causes of death were hemorrhagic shock, multiple organ failure, respiratory failure, and sepsis. The independent risk factors associated with death were acute kidney injury (odds ratio [OR] = 6.77), hypotension (OR = 15.08), and respiratory failure (OR = 3.65). Conclusion The frequency of deaths was low. Acute kidney injury, hypotension, and respiratory insufficiency were independent risk factors for maternal death. PMID:28099637

  8. Quantifying Safety Margin Using the Risk-Informed Safety Margin Characterization (RISMC)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grabaskas, David; Bucknor, Matthew; Brunett, Acacia

    2015-04-26

    The Risk-Informed Safety Margin Characterization (RISMC), developed by Idaho National Laboratory as part of the Light-Water Reactor Sustainability Project, utilizes a probabilistic safety margin comparison between a load and capacity distribution, rather than a deterministic comparison between two values, as is usually done in best-estimate plus uncertainty analyses. The goal is to determine the failure probability, or in other words, the probability of the system load equaling or exceeding the system capacity. While this method has been used in pilot studies, there has been little work conducted investigating the statistical significance of the resulting failure probability. In particular, it ismore » difficult to determine how many simulations are necessary to properly characterize the failure probability. This work uses classical (frequentist) statistics and confidence intervals to examine the impact in statistical accuracy when the number of simulations is varied. Two methods are proposed to establish confidence intervals related to the failure probability established using a RISMC analysis. The confidence interval provides information about the statistical accuracy of the method utilized to explore the uncertainty space, and offers a quantitative method to gauge the increase in statistical accuracy due to performing additional simulations.« less

  9. Early High-Frequency Oscillatory Ventilation in Pediatric Acute Respiratory Failure. A Propensity Score Analysis.

    PubMed

    Bateman, Scot T; Borasino, Santiago; Asaro, Lisa A; Cheifetz, Ira M; Diane, Shelley; Wypij, David; Curley, Martha A Q

    2016-03-01

    The use of high-frequency oscillatory ventilation (HFOV) for acute respiratory failure in children is prevalent despite the lack of efficacy data. To compare the outcomes of patients with acute respiratory failure managed with HFOV within 24-48 hours of endotracheal intubation with those receiving conventional mechanical ventilation (CMV) and/or late HFOV. This is a secondary analysis of data from the RESTORE (Randomized Evaluation of Sedation Titration for Respiratory Failure) study, a prospective cluster randomized clinical trial conducted between 2009 and 2013 in 31 U.S. pediatric intensive care units. Propensity score analysis, including degree of hypoxia in the model, compared the duration of mechanical ventilation and mortality of patients treated with early HFOV matched with those treated with CMV/late HFOV. Among 2,449 subjects enrolled in RESTORE, 353 patients (14%) were ever supported on HFOV, of which 210 (59%) had HFOV initiated within 24-48 hours of intubation. The propensity score model predicting the probability of receiving early HFOV included 1,064 patients (181 early HFOV vs. 883 CMV/late HFOV) with significant hypoxia (oxygenation index ≥ 8). The degree of hypoxia was the most significant contributor to the propensity score model. After adjusting for risk category, early HFOV use was associated with a longer duration of mechanical ventilation (hazard ratio, 0.75; 95% confidence interval, 0.64-0.89; P = 0.001) but not with mortality (odds ratio, 1.28; 95% confidence interval, 0.92-1.79; P = 0.15) compared with CMV/late HFOV. In adjusted models including important oxygenation variables, early HFOV was associated with a longer duration of mechanical ventilation. These analyses make supporting the current approach to HFOV less convincing.

  10. Initial use of echinocandins does not negatively influence outcome in Candida parapsilosis bloodstream infection: a propensity score analysis.

    PubMed

    Fernández-Ruiz, Mario; Aguado, José María; Almirante, Benito; Lora-Pablos, David; Padilla, Belén; Puig-Asensio, Mireia; Montejo, Miguel; García-Rodríguez, Julio; Pemán, Javier; Ruiz Pérez de Pipaón, Maite; Cuenca-Estrella, Manuel

    2014-05-01

    Concerns have arisen regarding the optimal antifungal regimen for Candida parapsilosis bloodstream infection (BSI) in view of its reduced susceptibility to echinocandins. The Prospective Population Study on Candidemia in Spain (CANDIPOP) is a prospective multicenter, population-based surveillance program on Candida BSI conducted through a 12-month period in 29 Spanish hospitals. Clinical isolates were identified by DNA sequencing, and antifungal susceptibility testing was performed by the European Committee on Antimicrobial Susceptibility Testing methodology. Predictors for clinical failure (all-cause mortality between days 3 to 30, or persistent candidemia for ≥72 hours after initiation of therapy) in episodes of C. parapsilosis species complex BSI were assessed by logistic regression analysis. We further analyzed the impact of echinocandin-based regimen as the initial antifungal therapy (within the first 72 hours) by using a propensity score approach. Among 752 episodes of Candida BSI identified, 200 (26.6%) were due to C. parapsilosis species complex. We finally analyzed 194 episodes occurring in 190 patients. Clinical failure occurred in 58 of 177 (32.8%) of evaluable episodes. Orotracheal intubation (adjusted odds ratio [AOR], 2.81; P = .018) and septic shock (AOR, 2.91; P = .081) emerged as risk factors for clinical failure, whereas early central venous catheter removal was protective (AOR, 0.43; P = .040). Neither univariate nor multivariate analysis revealed that the initial use of an echinocandin-based regimen had any impact on the risk of clinical failure. Incorporation of the propensity score into the model did not change this finding. The initial use of an echinocandin-based regimen does not seem to negatively influence outcome in C. parapsilosis BSI.

  11. Cost-Utility Analysis of the EVOLVO Study on Remote Monitoring for Heart Failure Patients With Implantable Defibrillators: Randomized Controlled Trial

    PubMed Central

    Landolina, Maurizio; Marzegalli, Maurizio; Lunati, Maurizio; Perego, Giovanni B; Guenzati, Giuseppe; Curnis, Antonio; Valsecchi, Sergio; Borghetti, Francesca; Borghi, Gabriella; Masella, Cristina

    2013-01-01

    Background Heart failure patients with implantable defibrillators place a significant burden on health care systems. Remote monitoring allows assessment of device function and heart failure parameters, and may represent a safe, effective, and cost-saving method compared to conventional in-office follow-up. Objective We hypothesized that remote device monitoring represents a cost-effective approach. This paper summarizes the economic evaluation of the Evolution of Management Strategies of Heart Failure Patients With Implantable Defibrillators (EVOLVO) study, a multicenter clinical trial aimed at measuring the benefits of remote monitoring for heart failure patients with implantable defibrillators. Methods Two hundred patients implanted with a wireless transmission–enabled implantable defibrillator were randomized to receive either remote monitoring or the conventional method of in-person evaluations. Patients were followed for 16 months with a protocol of scheduled in-office and remote follow-ups. The economic evaluation of the intervention was conducted from the perspectives of the health care system and the patient. A cost-utility analysis was performed to measure whether the intervention was cost-effective in terms of cost per quality-adjusted life year (QALY) gained. Results Overall, remote monitoring did not show significant annual cost savings for the health care system (€1962.78 versus €2130.01; P=.80). There was a significant reduction of the annual cost for the patients in the remote arm in comparison to the standard arm (€291.36 versus €381.34; P=.01). Cost-utility analysis was performed for 180 patients for whom QALYs were available. The patients in the remote arm gained 0.065 QALYs more than those in the standard arm over 16 months, with a cost savings of €888.10 per patient. Results from the cost-utility analysis of the EVOLVO study show that remote monitoring is a cost-effective and dominant solution. Conclusions Remote management of heart failure patients with implantable defibrillators appears to be cost-effective compared to the conventional method of in-person evaluations. Trial Registration ClinicalTrials.gov NCT00873899; http://clinicaltrials.gov/show/NCT00873899 (Archived by WebCite at http://www.webcitation.org/6H0BOA29f). PMID:23722666

  12. Effective technologies for noninvasive remote monitoring in heart failure.

    PubMed

    Conway, Aaron; Inglis, Sally C; Clark, Robyn A

    2014-06-01

    Trials of new technologies to remotely monitor for signs and symptoms of worsening heart failure are continually emerging. The extent to which technological differences impact the effectiveness of noninvasive remote monitoring for heart failure management is unknown. This study examined the effect of specific technology used for noninvasive remote monitoring of people with heart failure on all-cause mortality and heart failure-related hospitalizations. A subanalysis of a large systematic review and meta-analysis was conducted. Studies were stratified according to the specific type of technology used, and separate meta-analyses were performed. Four different types of noninvasive remote monitoring technologies were identified, including structured telephone calls, videophone, interactive voice response devices, and telemonitoring. Only structured telephone calls and telemonitoring were effective in reducing the risk of all-cause mortality (relative risk [RR]=0.87; 95% confidence interval [CI], 0.75-1.01; p=0.06; and RR=0.62; 95% CI, 0.50-0.77; p<0.0001, respectively) and heart failure-related hospitalizations (RR=0.77; 95% CI, 0.68-0.87; p<0.001; and RR=0.75; 95% CI, 0.63-0.91; p=0.003, respectively). More research data are required for videophone and interactive voice response technologies. This subanalysis identified that only two of the four specific technologies used for noninvasive remote monitoring in heart failure improved outcomes. When results of studies that involved these disparate technologies were combined in previous meta-analyses, significant improvements in outcomes were identified. As such, this study has highlighted implications for future meta-analyses of randomized controlled trials focused on evaluating the effectiveness of remote monitoring in heart failure.

  13. [Effect of hypophosphatemia on weaning success from mechanical ventilation].

    PubMed

    Kara, Atilla; Kızılarslanoğlu, Muhammet Cemal; Bolayır, Başak; Ortaç Ersoy, Ebru; Öcal, Serpil; Çakır, Banu; Tezcan, Sabahat; Topeli, Arzu

    2015-06-01

    Hypophosphatemia may cause acute respiratory failure and tissue hypoxia. In this study we investigated the effect of hypophosphatemia on weaning success. A nested case-control study was conducted in a retrospective cohort of 76 patients who received invasive mechanical ventilation in 2005-2010 in the Medical Intensive Care Unit (MICU) of university hospital. Case patients (failure group) were those who could not be weaned in the first trial or who required post-extubation mechanical ventilation after first extubation. Control patients (success group) were successfully extubated in the first weaning attempt. Frequency of hypophosphatemia (P level < 2.5 mg/dL) at admission was 23.7%. Weaning failure rate was 71.1%. Risk of weaning failure in the presence of hypophosphatemia was 88.9%, whereas risk in the absence of hypophosphatemia was 65.5%, resulting in risk ratio of 1.36 (1.06 - 1.74) (p= 0.096). Mean (± SD) P levels in the success and failure groups were 3.6 ± 1.0 and 3.2 ± 1.0 mg/dL, respectively (p= 0.113). Logistic regression analysis revealed four independent risk factors which were presence of underlying chronic pulmonary disease, high organ dysfunction score (SOFA) at admission, high blood urea nitrogen at the day of weaning trial and low P level at admission to predict weaning failure. Each 1 mg/dL increment in P level resulted in decreased probability of weaning failure with an OR of 0.43 (0.21-0.88). In conclusion, a relation between hypophosphatemia and weaning failure was determined which has to be confirmed with prospective cohort and interventional studies with adequate power.

  14. Failure mode analysis to predict product reliability.

    NASA Technical Reports Server (NTRS)

    Zemanick, P. P.

    1972-01-01

    The failure mode analysis (FMA) is described as a design tool to predict and improve product reliability. The objectives of the failure mode analysis are presented as they influence component design, configuration selection, the product test program, the quality assurance plan, and engineering analysis priorities. The detailed mechanics of performing a failure mode analysis are discussed, including one suggested format. Some practical difficulties of implementation are indicated, drawn from experience with preparing FMAs on the nuclear rocket engine program.

  15. Semiparametric regression analysis of failure time data with dependent interval censoring.

    PubMed

    Chen, Chyong-Mei; Shen, Pao-Sheng

    2017-09-20

    Interval-censored failure-time data arise when subjects are examined or observed periodically such that the failure time of interest is not examined exactly but only known to be bracketed between two adjacent observation times. The commonly used approaches assume that the examination times and the failure time are independent or conditionally independent given covariates. In many practical applications, patients who are already in poor health or have a weak immune system before treatment usually tend to visit physicians more often after treatment than those with better health or immune system. In this situation, the visiting rate is positively correlated with the risk of failure due to the health status, which results in dependent interval-censored data. While some measurable factors affecting health status such as age, gender, and physical symptom can be included in the covariates, some health-related latent variables cannot be observed or measured. To deal with dependent interval censoring involving unobserved latent variable, we characterize the visiting/examination process as recurrent event process and propose a joint frailty model to account for the association of the failure time and visiting process. A shared gamma frailty is incorporated into the Cox model and proportional intensity model for the failure time and visiting process, respectively, in a multiplicative way. We propose a semiparametric maximum likelihood approach for estimating model parameters and show the asymptotic properties, including consistency and weak convergence. Extensive simulation studies are conducted and a data set of bladder cancer is analyzed for illustrative purposes. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  16. Autotransplantation of teeth in humans: a systematic review and meta-analysis.

    PubMed

    Almpani, Konstantinia; Papageorgiou, Spyridon N; Papadopoulos, Moschos A

    2015-07-01

    The aim of this investigation was to assess the currently available evidence concerning the complications and risk factors influencing the outcome of autotransplantation of teeth in humans. Electronic searches were conducted to identify randomized controlled and prospective clinical trials. Risk of bias within studies was assessed with the Downs and Black tool. Random-effects meta-analyses were conducted to pool the adverse event rates and relative risks with their 95% confidence intervals. Risk of bias across studies was assessed with the GRADE framework followed by sensitivity analyses. Thirty-eight studies were included in the analysis. Reported complications included the need for extraction, failure, hypermobility, pulp necrosis, pulp obliteration, and root resorption. Pooled complication event rates varied considerably, with small studies (<100 teeth) reporting greater complication rates. The analysis of risk factors was associated with both the primary outcome (extraction need) and secondary outcomes (failure, hypermobility, pulp necrosis, pulp obliteration, root resorption). The stage of root development seems to influence both the future survival, as well as the success of the transplanted teeth. Teeth with open apex were less likely to be extracted in comparison to teeth with closed apex (3 studies; 413 teeth; relative risk 0.3; 95% confidence interval 0.2-0.6). Due to the small number of the contributing studies, their methodological limitations, and the heterogeneous results reported, no firm conclusions can be drawn. Root development of the donor teeth has been established as one the most important factor related to the success of tooth autotransplantation.

  17. Failure Analysis at the Kennedy Space Center

    NASA Technical Reports Server (NTRS)

    Salazar, Victoria L.; Wright, M. Clara

    2010-01-01

    History has shown that failures occur in every engineering endeavor, and what we learn from those failures contributes to the knowledge base to safely complete future missions. The necessity of failure analysis is at its apex at the end of one aged program and at the beginning of a new and untested program. The information that we gain through failure analysis corrects the deficiencies in the current vehicle to make the next generation of vehicles more efficient and safe. The Failure Analysis and Materials Evaluation Branch in the Materials Science Division at the Kennedy Space Center performs metallurgical, mechanical, electrical, and non-metallic materials failure analyses and accident investigations on both flight hardware and ground support equipment for the Space Shuttle, International Space Station, Constellation, and Launch Services Programs. This paper will explore a variety of failure case studies at the Kennedy Space Center and the lessons learned that can be applied in future programs.

  18. Failure Mode Identification Through Clustering Analysis

    NASA Technical Reports Server (NTRS)

    Arunajadai, Srikesh G.; Stone, Robert B.; Tumer, Irem Y.; Clancy, Daniel (Technical Monitor)

    2002-01-01

    Research has shown that nearly 80% of the costs and problems are created in product development and that cost and quality are essentially designed into products in the conceptual stage. Currently, failure identification procedures (such as FMEA (Failure Modes and Effects Analysis), FMECA (Failure Modes, Effects and Criticality Analysis) and FTA (Fault Tree Analysis)) and design of experiments are being used for quality control and for the detection of potential failure modes during the detail design stage or post-product launch. Though all of these methods have their own advantages, they do not give information as to what are the predominant failures that a designer should focus on while designing a product. This work uses a functional approach to identify failure modes, which hypothesizes that similarities exist between different failure modes based on the functionality of the product/component. In this paper, a statistical clustering procedure is proposed to retrieve information on the set of predominant failures that a function experiences. The various stages of the methodology are illustrated using a hypothetical design example.

  19. Retrospective Analysis of Outcome Differences in Preoperative Concurrent Chemoradiation With or Without Elective Nodal Irradiation for Esophageal Squamous Cell Carcinoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hsu, Feng-Ming; Cancer Research Center, National Taiwan University College of Medicine, Taipei, Taiwan; Graduate Institute of Biomedical Electronics and Bioinformatics, National Taiwan University, Taipei, Taiwan

    2011-11-15

    Purpose: To evaluate the efficacy and patterns of failure of elective nodal irradiation (ENI) in patients with esophageal squamous cell carcinoma (SCC) undergoing preoperative concurrent chemoradiation (CCRT) followed by radical surgery. Methods and Materials: We retrospectively studied 118 patients with AJCC Stage II to III esophageal SCC undergoing preoperative CCRT (median, 36 Gy), followed by radical esophagectomy. Of them, 73 patients (62%) had ENI and 45 patients (38%) had no ENI. Patients with ENI received radiotherapy to either supraclavicular (n = 54) or celiac (n = 19) lymphatics. Fifty-six patients (57%) received chemotherapy with paclitaxel plus cisplatin. The 3-year progression-freemore » survival, overall survival, and patterns of failure were analyzed. Distant nodal recurrence was classified into M1a and M1b regions. A separate analysis using matched cases was conducted. Results: The median follow-up was 38 months. There were no differences in pathological complete response rate (p = 0.12), perioperative mortality rate (p = 0.48), or delayed Grade 3 or greater cardiopulmonary toxicities (p = 0.44), between the groups. More patients in the non-ENI group had M1a failure than in the ENI group, with 3-year rates of 11% and 3%, respectively (p = 0.05). However, the 3-year isolated distant nodal (M1a + M1b) failure rates were not different (ENI, 10%; non-ENI, 14%; p = 0.29). In multivariate analysis, pathological nodal status was the only independent prognostic factor associated with overall survival (hazard ratio = 1.78, p = 0.045). The 3-year overall survival and progression-free survival were 45% and 45%, respectively, in the ENI group, and 52% and 43%, respectively, in the non-ENI group (p = 0.31 and 0.89, respectively). Matched cases analysis did not show a statistical difference in outcomes between the groups. Conclusions: ENI reduced the M1a failure rate but was not associated with improved outcomes in patients undergoing preoperative CCRT for esophageal SCC. Pathological nodal metastasis predicted poor outcome.« less

  20. Free versus perforator-pedicled propeller flaps in lower extremity reconstruction: What is the safest coverage? A meta-analysis.

    PubMed

    Bekara, Farid; Herlin, Christian; Somda, Serge; de Runz, Antoine; Grolleau, Jean Louis; Chaput, Benoit

    2018-01-01

    Currently, increasingly reconstructive surgeon consider the failure rates of perforator propeller flaps especially in the distal third of the lower leg are too important and prefer to return to the use of free flap at first line option with failure rates frequently lower than 5%. So, we performed a systematic review with meta-analysis comparing free flaps (perforator-based or not) and pedicled-propeller flaps to respond to the question "what is the safest coverage for distal third of the lower limb?" This review was conducted according to PRISMA criteria. From 1991 to 2015, MEDLINE®, Pubmed central, Embase and Cochrane Library were searched. The pooled estimations were performed by meta-analysis. The homogeneity Q statistic and the I 2 index were computed. We included 36 articles for free flaps (1,226 flaps) and 19 articles for pedicled-propeller flaps (302 flaps). The overall failure rate was 3.9% [95%CI:2.6-5.3] for free flaps and 2.77% [95%CI:0.0-5.6] for pedicled-propeller flaps (P = 0.36). The complication rates were 19.0% for free flaps and 21.4% for pedicled-propeller flaps (P = 0.37). In more detail, we noted for free flaps versus pedicled-propeller flaps: partial necrosis (2.70 vs. 6.88%, P = 0.001%), wound dehiscence (2.38 vs. 0.26%, P = 0.018), infection (4.45 vs. 1.22%, P = 0.009). The coverage failure rate was 5.24% [95%CI:3.68-6.81] versus 2.99% [95%CI:0.38-5.60] without significant difference (P = 0.016). In the lower limb the complications are not rare and many teams consider the free flaps to be safer. In this meta-analysis we provide evidence that failure and overall complications rate of perforator propeller flaps are comparable with free flaps. Although, partial necrosis is significantly higher for pedicled-propeller flaps than free flaps, in reality the success of coverage appears similar. © 2016 Wiley Periodicals, Inc. Microsurgery, 38:109-119, 2018. © 2016 Wiley Periodicals, Inc.

  1. Retrospective analysis of outcome differences in preoperative concurrent chemoradiation with or without elective nodal irradiation for esophageal squamous cell carcinoma.

    PubMed

    Hsu, Feng-Ming; Lee, Jang-Ming; Huang, Pei-Ming; Lin, Chia-Chi; Hsu, Chih-Hung; Tsai, Yu-Chieh; Lee, Yung-Chie; Chia-Hsien Cheng, Jason

    2011-11-15

    To evaluate the efficacy and patterns of failure of elective nodal irradiation (ENI) in patients with esophageal squamous cell carcinoma (SCC) undergoing preoperative concurrent chemoradiation (CCRT) followed by radical surgery. We retrospectively studied 118 patients with AJCC Stage II to III esophageal SCC undergoing preoperative CCRT (median, 36 Gy), followed by radical esophagectomy. Of them, 73 patients (62%) had ENI and 45 patients (38%) had no ENI. Patients with ENI received radiotherapy to either supraclavicular (n = 54) or celiac (n = 19) lymphatics. Fifty-six patients (57%) received chemotherapy with paclitaxel plus cisplatin. The 3-year progression-free survival, overall survival, and patterns of failure were analyzed. Distant nodal recurrence was classified into M1a and M1b regions. A separate analysis using matched cases was conducted. The median follow-up was 38 months. There were no differences in pathological complete response rate (p = 0.12), perioperative mortality rate (p = 0.48), or delayed Grade 3 or greater cardiopulmonary toxicities (p = 0.44), between the groups. More patients in the non-ENI group had M1a failure than in the ENI group, with 3-year rates of 11% and 3%, respectively (p = 0.05). However, the 3-year isolated distant nodal (M1a + M1b) failure rates were not different (ENI, 10%; non-ENI, 14%; p = 0.29). In multivariate analysis, pathological nodal status was the only independent prognostic factor associated with overall survival (hazard ratio = 1.78, p = 0.045). The 3-year overall survival and progression-free survival were 45% and 45%, respectively, in the ENI group, and 52% and 43%, respectively, in the non-ENI group (p = 0.31 and 0.89, respectively). Matched cases analysis did not show a statistical difference in outcomes between the groups. ENI reduced the M1a failure rate but was not associated with improved outcomes in patients undergoing preoperative CCRT for esophageal SCC. Pathological nodal metastasis predicted poor outcome. Copyright © 2011 Elsevier Inc. All rights reserved.

  2. Analysis of in vitro fertilization data with multiple outcomes using discrete time-to-event analysis

    PubMed Central

    Maity, Arnab; Williams, Paige; Ryan, Louise; Missmer, Stacey; Coull, Brent; Hauser, Russ

    2014-01-01

    In vitro fertilization (IVF) is an increasingly common method of assisted reproductive technology. Because of the careful observation and followup required as part of the procedure, IVF studies provide an ideal opportunity to identify and assess clinical and demographic factors along with environmental exposures that may impact successful reproduction. A major challenge in analyzing data from IVF studies is handling the complexity and multiplicity of outcome, resulting from both multiple opportunities for pregnancy loss within a single IVF cycle in addition to multiple IVF cycles. To date, most evaluations of IVF studies do not make use of full data due to its complex structure. In this paper, we develop statistical methodology for analysis of IVF data with multiple cycles and possibly multiple failure types observed for each individual. We develop a general analysis framework based on a generalized linear modeling formulation that allows implementation of various types of models including shared frailty models, failure specific frailty models, and transitional models, using standard software. We apply our methodology to data from an IVF study conducted at the Brigham and Women’s Hospital, Massachusetts. We also summarize the performance of our proposed methods based on a simulation study. PMID:24317880

  3. Failure Mode and Effects Analysis: views of hospital staff in the UK.

    PubMed

    Shebl, Nada; Franklin, Bryony; Barber, Nick; Burnett, Susan; Parand, Anam

    2012-01-01

    To explore health care professionals' experiences and perceptions of Failure Mode and Effects Analysis (FMEA), a team-based, prospective risk analysis technique. Semi-structured interviews were conducted with 21 operational leads (20 pharmacists, one nurse) in medicines management teams of hospitals participating in a national quality improvement programme. Interviews were transcribed, coded and emergent themes identified using framework analysis. Themes identified included perceptions and experiences of participants with FMEA, validity and reliability issues, and FMEA's use in practice. FMEA was considered to be a structured but subjective process that helps health care professionals get together to identify high risk areas of care. Both positive and negative opinions were expressed, with the majority of interviewees expressing positive views towards FMEA in relation to its structured nature and the use of a multidisciplinary team. Other participants criticised FMEA for being subjective and lacking validity. Most likely to restrict its widespread use were its time consuming nature and its perceived lack of validity and reliability. FMEA is a subjective but systematic tool that helps identify high risk areas, but its time consuming nature, difficulty with the scores and perceived lack of validity and reliability may limit its widespread use.

  4. Using survival analysis of artificial and Real Brewer's sparrow (Spizella breweri breweri) nests to model site level and nest site factors associated with nest success in the South Okanagan region of Canada

    Treesearch

    Pam Krannitz Kym Welstead

    2005-01-01

    Predation is the predominant cause of nest failure for the Brewer's Sparrow (Spizella breweri breweri), a provincially red-listed shrub-steppe species that has experienced significant declines throughout most of its range. We monitored Brewer’s Sparrow nests and conducted an artificial nest experiment, in the South Okanagan Valley,...

  5. Analytical Prediction of the Seismic Response of a Reinforced Concrete Containment Vessel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    James, R.J.; Rashid, Y.R.; Cherry, J.L.

    Under the sponsorship of the Ministry of International Trade and Industry (MITI) of Japan, the Nuclear Power Engineering Corporation (NUPEC) is investigating the seismic behavior of a Reinforced Concrete Containment Vessel (RCCV) through scale-model testing using the high-performance shaking table at the Tadotsu Engineering Laboratory. A series of tests representing design-level seismic ground motions was initially conducted to gather valuable experimental measurements for use in design verification. Additional tests will be conducted with increasing amplifications of the seismic input until a structural failure of the test model occurs. In a cooperative program with NUPEC, the US Nuclear Regulatory Commission (USNRC),more » through Sandia National Laboratories (SNL), is conducting analytical research on the seismic behavior of RCCV structures. As part of this program, pretest analytical predictions of the model tests are being performed. The dynamic time-history analysis utilizes a highly detailed concrete constitutive model applied to a three-dimensional finite element representation of the test structure. This paper describes the details of the analysis model and provides analysis results.« less

  6. Graphical Displays Assist In Analysis Of Failures

    NASA Technical Reports Server (NTRS)

    Pack, Ginger; Wadsworth, David; Razavipour, Reza

    1995-01-01

    Failure Environment Analysis Tool (FEAT) computer program enables people to see and better understand effects of failures in system. Uses digraph models to determine what will happen to system if set of failure events occurs and to identify possible causes of selected set of failures. Digraphs or engineering schematics used. Also used in operations to help identify causes of failures after they occur. Written in C language.

  7. A Framework for Creating a Function-based Design Tool for Failure Mode Identification

    NASA Technical Reports Server (NTRS)

    Arunajadai, Srikesh G.; Stone, Robert B.; Tumer, Irem Y.; Clancy, Daniel (Technical Monitor)

    2002-01-01

    Knowledge of potential failure modes during design is critical for prevention of failures. Currently industries use procedures such as Failure Modes and Effects Analysis (FMEA), Fault Tree analysis, or Failure Modes, Effects and Criticality analysis (FMECA), as well as knowledge and experience, to determine potential failure modes. When new products are being developed there is often a lack of sufficient knowledge of potential failure mode and/or a lack of sufficient experience to identify all failure modes. This gives rise to a situation in which engineers are unable to extract maximum benefits from the above procedures. This work describes a function-based failure identification methodology, which would act as a storehouse of information and experience, providing useful information about the potential failure modes for the design under consideration, as well as enhancing the usefulness of procedures like FMEA. As an example, the method is applied to fifteen products and the benefits are illustrated.

  8. Transitional care for formerly incarcerated persons with HIV: protocol for a realist review.

    PubMed

    Tsang, Jenkin; Mishra, Sharmistha; Rowe, Janet; O'Campo, Patricia; Ziegler, Carolyn; Kouyoumdjian, Fiona G; Matheson, Flora I; Bayoumi, Ahmed M; Zahid, Shatabdy; Antoniou, Tony

    2017-02-13

    Little is known about the mechanisms that influence the success or failure of programs to facilitate re-engagement with health and social services for formerly incarcerated persons with HIV. This review aims to identify how interventions to address such transitions work, for whom and under what circumstances. We will use realist review methodology to conduct our analysis. We will systematically search electronic databases and grey literature for English language qualitative and quantitative studies of interventions. Two investigators will independently screen citations and full-text articles, abstract data, appraise study quality and synthesize the literature. Data analysis will include identifying context-mechanism-outcome configurations, exploring and comparing patterns in these configurations, making comparisons across contexts and developing explanatory frameworks. This review will identify mechanisms that influence the success or failure of transition interventions for formerly incarcerated individuals with HIV. The findings will be integrated with those from complementary qualitative and quantitative studies to inform future interventions. PROSPERO CRD42016040054.

  9. Effect of hydraulic hysteresis on the stability of infinite slopes under steady infiltration

    USGS Publications Warehouse

    Chen, Pan; Mirus, Benjamin B.; Lu, Ning; Godt, Jonathan W.

    2017-01-01

    Hydraulic hysteresis, including capillary soil water retention (SWR), air entrapment SWR, and hydraulic conductivity, is a common phenomenon in unsaturated soils. However, the influence of hydraulic hysteresis on suction stress, and subsequently slope stability, is generally ignored. This paper examines the influence of each of these three types of hysteresis on slope stability using an infinite slope stability analysis under steady infiltration conditions. First, hypothetical slopes for representative silty and sandy soils are examined. Then a monitored hillslope in the San Francisco Bay Area, California is assessed, using observed rainfall conditions and measured hydraulic and geotechnical properties of the colluvial soil. Results show that profiles of suction stress and the corresponding factor of safety are generally strongly affected by hydraulic hysteresis. Results suggest that each of the three types of hydraulic hysteresis may play a major role in the occurrence of slope failure, indicating that ignoring hydraulic hysteresis will likely lead to underestimates of failure potential and hence to inaccurate slope stability analysis.

  10. Feasibility of Using Elastic Wave Velocity Monitoring for Early Warning of Rainfall-Induced Slope Failure

    PubMed Central

    Chen, Yulong; Irfan, Muhammad; Uchimura, Taro; Zhang, Ke

    2018-01-01

    Rainfall-induced landslides are one of the most widespread slope instability phenomena posing a serious risk to public safety worldwide so that their temporal prediction is of great interest to establish effective warning systems. The objective of this study is to determine the effectiveness of elastic wave velocities in the surface layer of the slope in monitoring, prediction and early warning of landslide. The small-scale fixed and varied, and large-scale slope model tests were conducted. Analysis of the results has established that the elastic wave velocity continuously decreases in response of moisture content and deformation and there was a distinct surge in the decrease rate of wave velocity when failure was initiated. Based on the preliminary results of this analysis, the method using the change in elastic wave velocity proves superior for landslide early warning and suggests that a warning be issued at switch of wave velocity decrease rate. PMID:29584699

  11. Comparison among different retrofitting strategies for the vulnerability reduction of masonry bell towers

    NASA Astrophysics Data System (ADS)

    Milani, Gabriele; Shehu, Rafael; Valente, Marco

    2017-11-01

    This paper investigates the effectiveness of reducing the seismic vulnerability of masonry towers by means of innovative and traditional strengthening techniques. The followed strategy for providing the optimal retrofitting for masonry towers subjected to seismic risk relies on preventing active failure mechanisms. These vulnerable mechanisms are pre-assigned failure patterns based on the crack patterns experienced during the past seismic events. An upper bound limit analysis strategy is found suitable to be applied for simplified tower models in their present state and the proposed retrofitted ones. Taking into consideration the variability of geometrical features and the uncertainty of the strengthening techniques, Monte Carlo simulations are implemented into the limit analysis. In this framework a wide range of idealized cases are covered by the conducted analyses. The retrofitting strategies aim to increase the shear strength and the overturning load carrying capacity in order to reduce vulnerability. This methodology gives the possibility to use different materials which can fulfill the structural implementability requirements.

  12. A distributed real-time model of degradation in a solid oxide fuel cell, part II: Analysis of fuel cell performance and potential failures

    NASA Astrophysics Data System (ADS)

    Zaccaria, V.; Tucker, D.; Traverso, A.

    2016-09-01

    Solid oxide fuel cells are characterized by very high efficiency, low emissions level, and large fuel flexibility. Unfortunately, their elevated costs and relatively short lifetimes reduce the economic feasibility of these technologies at the present time. Several mechanisms contribute to degrade fuel cell performance during time, and the study of these degradation modes and potential mitigation actions is critical to ensure the durability of the fuel cell and their long-term stability. In this work, localized degradation of a solid oxide fuel cell is modeled in real-time and its effects on various cell parameters are analyzed. Profile distributions of overpotential, temperature, heat generation, and temperature gradients in the stack are investigated during degradation. Several causes of failure could occur in the fuel cell if no proper control actions are applied. A local analysis of critical parameters conducted shows where the issues are and how they could be mitigated in order to extend the life of the cell.

  13. Analysis of failure in patients with adenoid cystic carcinoma of the head and neck. An international collaborative study.

    PubMed

    Amit, Moran; Binenbaum, Yoav; Sharma, Kanika; Ramer, Naomi; Ramer, Ilana; Agbetoba, Abib; Miles, Brett; Yang, Xinjie; Lei, Delin; Bjøerndal, Kristine; Godballe, Christian; Mücke, Thomas; Wolff, Klaus-Dietrich; Fliss, Dan; Eckardt, André M; Copelli, Chiara; Sesenna, Enrico; Palmer, Frank; Patel, Snehal; Gil, Ziv

    2014-07-01

    Adenoid cystic carcinoma (ACC) is a locally aggressive tumor with a high prevalence of distant metastases. The purpose of this study was to identify independent predictors of outcome and to characterize the patterns of failure. An international retrospective review was conducted of 489 patients with ACC treated between 1985 and 2011 in 9 cancer centers worldwide. Five-year overall-survival (OS), disease-specific survival (DSS), and disease-free survival (DFS) were 76%, 80%, and 68%, respectively. Independent predictors of OS and DSS were: age, site, N classification, and presence of distant metastases. N classification, age, and bone invasion were associated with DFS on multivariate analysis. Age, tumor site, orbital invasion, and N classification were independent predictors of distant metastases. The clinical course of ACC is slow but persistent. Paranasal sinus origin is associated with the lowest distant metastases rate but with the poorest outcome. These prognostic estimates should be considered when tailoring treatment for patients with ACC. Copyright © 2013 Wiley Periodicals, Inc.

  14. Integration of Value Stream Map and Healthcare Failure Mode and Effect Analysis into Six Sigma Methodology to Improve Process of Surgical Specimen Handling.

    PubMed

    Hung, Sheng-Hui; Wang, Pa-Chun; Lin, Hung-Chun; Chen, Hung-Ying; Su, Chao-Ton

    2015-01-01

    Specimen handling is a critical patient safety issue. Problematic handling process, such as misidentification (of patients, surgical site, and specimen counts), specimen loss, or improper specimen preparation can lead to serious patient harms and lawsuits. Value stream map (VSM) is a tool used to find out non-value-added works, enhance the quality, and reduce the cost of the studied process. On the other hand, healthcare failure mode and effect analysis (HFMEA) is now frequently employed to avoid possible medication errors in healthcare process. Both of them have a goal similar to Six Sigma methodology for process improvement. This study proposes a model that integrates VSM and HFMEA into the framework, which mainly consists of define, measure, analyze, improve, and control (DMAIC), of Six Sigma. A Six Sigma project for improving the process of surgical specimen handling in a hospital was conducted to demonstrate the effectiveness of the proposed model.

  15. Critical joints in large composite aircraft structure

    NASA Technical Reports Server (NTRS)

    Nelson, W. D.; Bunin, B. L.; Hart-Smith, L. J.

    1983-01-01

    A program was conducted at Douglas Aircraft Company to develop the technology for critical structural joints of composite wing structure that meets design requirements for a 1990 commercial transport aircraft. The prime objective of the program was to demonstrate the ability to reliably predict the strength of large bolted composite joints. Ancillary testing of 180 specimens generated data on strength and load-deflection characteristics which provided input to the joint analysis. Load-sharing between fasteners in multirow bolted joints was computed by the nonlinear analysis program A4EJ. This program was used to predict strengths of 20 additional large subcomponents representing strips from a wing root chordwise splice. In most cases, the predictions were accurate to within a few percent of the test results. In some cases, the observed mode of failure was different than anticipated. The highlight of the subcomponent testing was the consistent ability to achieve gross-section failure strains close to 0.005. That represents a considerable improvement over the state of the art.

  16. 30 CFR 585.815 - What must I do if I have facility damage or an equipment failure?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Conducted Under SAPs, COPs and GAPs Equipment Failure and Adverse Environmental Effects § 585.815 What must... failure under § 585.831, BOEM may require you to revise your SAP, COP, or GAP to describe how you will address the facility damage or failure as required by § 585.634 (COP), § 585.617 (SAP), § 585.655 (GAP...

  17. 30 CFR 585.815 - What must I do if I have facility damage or an equipment failure?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Conducted Under SAPs, COPs and GAPs Equipment Failure and Adverse Environmental Effects § 585.815 What must... failure under § 585.831, BOEM may require you to revise your SAP, COP, or GAP to describe how you will address the facility damage or failure as required by § 585.634 (COP), § 585.617 (SAP), § 585.655 (GAP...

  18. 30 CFR 585.815 - What must I do if I have facility damage or an equipment failure?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Conducted Under SAPs, COPs and GAPs Equipment Failure and Adverse Environmental Effects § 585.815 What must... failure under § 585.831, BOEM may require you to revise your SAP, COP, or GAP to describe how you will address the facility damage or failure as required by § 585.634 (COP), § 585.617 (SAP), § 585.655 (GAP...

  19. Analysis of the surface effects on adhesion in MEMS structures

    NASA Astrophysics Data System (ADS)

    Rusu, F.; Pustan, M.; Bîrleanu, C.; Müller, R.; Voicu, R.; Baracu, A.

    2015-12-01

    One of the main failure causes in microelectromechanical systems (MEMS) is stiction. Stiction is the adhesion of contacting surfaces due to surface forces. Adhesion force depends on the operating conditions and is influenced by the contact area. In this study, the adhesion force between MEMS materials and the AFM tips is analyzed using the spectroscopy in point mode of the AFM. The aim is to predict the stiction failure mode in MEMS. The investigated MEMS materials are silicon, polysilicon, platinum, aluminum, and gold. Three types of investigations were conducted. The first one aimed to determine the variation of the adhesion force with respect to the variation of the roughness. The roughness has a strong influence on the adhesion because the contact area between components increases if the roughness decreases. The second type of investigation aimed to determine the adhesion force in multiple points of each considered sample. The values obtained experimentally for the adhesion force were also validated using the JKR and DMT models. The third type of investigation was conducted with the purpose of determining the influence of the temperature on the adhesion force.

  20. Co-occurring woody species have diverse hydraulic strategies and mortality rates during an extreme drought: Belowground hydraulic failure during drought

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, Daniel M.; Domec, Jean-Christophe; Carter Berry, Z.

    From 2011 to 2013, Texas experienced its worst drought in recorded history. This event provided a unique natural experiment to assess species-specific responses to extreme drought and mortality of four co-occurring woody species: Quercus fusiformis, Diospyros texana, Prosopis glandulosa and Juniperus ashei. We examined hypothesized mechanisms that could promote these species’ diverse mortality patterns using post-drought measurements on surviving trees coupled to retrospective process modeling. The species exhibited a wide range of gas exchange responses, hydraulic strategies, and mortality rates. Multiple proposed indices of mortality mechanisms were not consistent with the observed mortality patterns across species, including measures of iso/anisohydry,more » photosynthesis, carbohydrate depletion, and hydraulic safety margins. Large losses of growing season whole-tree conductance (driven by belowground losses of conductance), and shallower rooting depths, were associated with species that exhibited greater mortality. Based on this retrospective analysis, we suggest that species more vulnerable to drought were more likely to have succumbed to hydraulic failure belowground.« less

  1. Experimental and Numerical Analysis of Triaxially Braided Composites Utilizing a Modified Subcell Modeling Approach

    NASA Technical Reports Server (NTRS)

    Cater, Christopher; Xiao, Xinran; Goldberg, Robert K.; Kohlman, Lee W.

    2015-01-01

    A combined experimental and analytical approach was performed for characterizing and modeling triaxially braided composites with a modified subcell modeling strategy. Tensile coupon tests were conducted on a [0deg/60deg/-60deg] braided composite at angles of 0deg, 30deg, 45deg, 60deg and 90deg relative to the axial tow of the braid. It was found that measured coupon strength varied significantly with the angle of the applied load and each coupon direction exhibited unique final failures. The subcell modeling approach implemented into the finite element software LS-DYNA was used to simulate the various tensile coupon test angles. The modeling approach was successful in predicting both the coupon strength and reported failure mode for the 0deg, 30deg and 60deg loading directions. The model over-predicted the strength in the 90deg direction; however, the experimental results show a strong influence of free edge effects on damage initiation and failure. In the absence of these local free edge effects, the subcell modeling approach showed promise as a viable and computationally efficient analysis tool for triaxially braided composite structures. Future work will focus on validation of the approach for predicting the impact response of the braided composite against flat panel impact tests.

  2. Experimental and Numerical Analysis of Triaxially Braided Composites Utilizing a Modified Subcell Modeling Approach

    NASA Technical Reports Server (NTRS)

    Cater, Christopher; Xiao, Xinran; Goldberg, Robert K.; Kohlman, Lee W.

    2015-01-01

    A combined experimental and analytical approach was performed for characterizing and modeling triaxially braided composites with a modified subcell modeling strategy. Tensile coupon tests were conducted on a [0deg/60deg/-60deg] braided composite at angles [0deg, 30deg, 45deg, 60deg and 90deg] relative to the axial tow of the braid. It was found that measured coupon strength varied significantly with the angle of the applied load and each coupon direction exhibited unique final failures. The subcell modeling approach implemented into the finite element software LS-DYNA was used to simulate the various tensile coupon test angles. The modeling approach was successful in predicting both the coupon strength and reported failure mode for the 0deg, 30deg and 60deg loading directions. The model over-predicted the strength in the 90deg direction; however, the experimental results show a strong influence of free edge effects on damage initiation and failure. In the absence of these local free edge effects, the subcell modeling approach showed promise as a viable and computationally efficient analysis tool for triaxially braided composite structures. Future work will focus on validation of the approach for predicting the impact response of the braided composite against flat panel impact tests.

  3. Seismic energy data analysis of Merapi volcano to test the eruption time prediction using materials failure forecast method (FFM)

    NASA Astrophysics Data System (ADS)

    Anggraeni, Novia Antika

    2015-04-01

    The test of eruption time prediction is an effort to prepare volcanic disaster mitigation, especially in the volcano's inhabited slope area, such as Merapi Volcano. The test can be conducted by observing the increase of volcanic activity, such as seismicity degree, deformation and SO2 gas emission. One of methods that can be used to predict the time of eruption is Materials Failure Forecast Method (FFM). Materials Failure Forecast Method (FFM) is a predictive method to determine the time of volcanic eruption which was introduced by Voight (1988). This method requires an increase in the rate of change, or acceleration of the observed volcanic activity parameters. The parameter used in this study is the seismic energy value of Merapi Volcano from 1990 - 2012. The data was plotted in form of graphs of seismic energy rate inverse versus time with FFM graphical technique approach uses simple linear regression. The data quality control used to increase the time precision employs the data correlation coefficient value of the seismic energy rate inverse versus time. From the results of graph analysis, the precision of prediction time toward the real time of eruption vary between -2.86 up to 5.49 days.

  4. Seismic energy data analysis of Merapi volcano to test the eruption time prediction using materials failure forecast method (FFM)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anggraeni, Novia Antika, E-mail: novia.antika.a@gmail.com

    The test of eruption time prediction is an effort to prepare volcanic disaster mitigation, especially in the volcano’s inhabited slope area, such as Merapi Volcano. The test can be conducted by observing the increase of volcanic activity, such as seismicity degree, deformation and SO2 gas emission. One of methods that can be used to predict the time of eruption is Materials Failure Forecast Method (FFM). Materials Failure Forecast Method (FFM) is a predictive method to determine the time of volcanic eruption which was introduced by Voight (1988). This method requires an increase in the rate of change, or acceleration ofmore » the observed volcanic activity parameters. The parameter used in this study is the seismic energy value of Merapi Volcano from 1990 – 2012. The data was plotted in form of graphs of seismic energy rate inverse versus time with FFM graphical technique approach uses simple linear regression. The data quality control used to increase the time precision employs the data correlation coefficient value of the seismic energy rate inverse versus time. From the results of graph analysis, the precision of prediction time toward the real time of eruption vary between −2.86 up to 5.49 days.« less

  5. Elastic Rock Heterogeneity Controls Brittle Rock Failure during Hydraulic Fracturing

    NASA Astrophysics Data System (ADS)

    Langenbruch, C.; Shapiro, S. A.

    2014-12-01

    For interpretation and inversion of microseismic data it is important to understand, which properties of the reservoir rock control the occurrence probability of brittle rock failure and associated seismicity during hydraulic stimulation. This is especially important, when inverting for key properties like permeability and fracture conductivity. Although it became accepted that seismic events are triggered by fluid flow and the resulting perturbation of the stress field in the reservoir rock, the magnitude of stress perturbations, capable of triggering failure in rocks, can be highly variable. The controlling physical mechanism of this variability is still under discussion. We compare the occurrence of microseismic events at the Cotton Valley gas field to elastic rock heterogeneity, obtained from measurements along the treatment wells. The heterogeneity is characterized by scale invariant fluctuations of elastic properties. We observe that the elastic heterogeneity of the rock formation controls the occurrence of brittle failure. In particular, we find that the density of events is increasing with the Brittleness Index (BI) of the rock, which is defined as a combination of Young's modulus and Poisson's ratio. We evaluate the physical meaning of the BI. By applying geomechanical investigations we characterize the influence of fluctuating elastic properties in rocks on the probability of brittle rock failure. Our analysis is based on the computation of stress fluctuations caused by elastic heterogeneity of rocks. We find that elastic rock heterogeneity causes stress fluctuations of significant magnitude. Moreover, the stress changes necessary to open and reactivate fractures in rocks are strongly related to fluctuations of elastic moduli. Our analysis gives a physical explanation to the observed relation between elastic heterogeneity of the rock formation and the occurrence of brittle failure during hydraulic reservoir stimulations. A crucial factor for understanding seismicity in unconventional reservoirs is the role of anisotropy of rocks. We evaluate an elastic VTI rock model corresponding to a shale gas reservoir in the Horn River Basin to understand the relation between stress, event occurrence and elastic heterogeneity in anisotropic rocks.

  6. Damage Simulation in Non-Crimp Fabric Composite Plates Subjected to Impact Loads

    NASA Technical Reports Server (NTRS)

    Satyanarayana, Arunkumar; Bogert, Philip B.; Aitharaju, Venkat; Aashat, Satvir; Kia, Hamid

    2014-01-01

    Progressive failure analysis (PFA) of non-crimp fabric (NCF) composite laminates subjected to low velocity impact loads was performed using the COmplete STress Reduction (COSTR) damage model implemented through VUMAT and UMAT41 user subroutines in the frame works of the commercial finite element programs ABAQUS/Explicit and LS-DYNA, respectively. To validate the model, low velocity experiments were conducted and detailed correlations between the predictions and measurements for both intra-laminar and inter-laminar failures were made. The developed material and damage model predicts the peak impact load and duration very close with the experimental results. Also, the simulation results of delamination damage between the ply interfaces, in-plane matrix damages and fiber damages were all in good agreement with the measurements from the non-destructive evaluation data.

  7. Ablation study of tungsten-based nuclear thermal rocket fuel

    NASA Astrophysics Data System (ADS)

    Smith, Tabitha Elizabeth Rose

    The research described in this thesis has been performed in order to support the materials research and development efforts of NASA Marshall Space Flight Center (MSFC), of Tungsten-based Nuclear Thermal Rocket (NTR) fuel. The NTR was developed to a point of flight readiness nearly six decades ago and has been undergoing gradual modification and upgrading since then. Due to the simplicity in design of the NTR, and also in the modernization of the materials fabrication processes of nuclear fuel since the 1960's, the fuel of the NTR has been upgraded continuously. Tungsten-based fuel is of great interest to the NTR community, seeking to determine its advantages over the Carbide-based fuel of the previous NTR programs. The materials development and fabrication process contains failure testing, which is currently being conducted at MSFC in the form of heating the material externally and internally to replicate operation within the nuclear reactor of the NTR, such as with hot gas and RF coils. In order to expand on these efforts, experiments and computational studies of Tungsten and a Tungsten Zirconium Oxide sample provided by NASA have been conducted for this dissertation within a plasma arc-jet, meant to induce ablation on the material. Mathematical analysis was also conducted, for purposes of verifying experiments and making predictions. The computational method utilizes Anisimov's kinetic method of plasma ablation, including a thermal conduction parameter from the Chapman Enskog expansion of the Maxwell Boltzmann equations, and has been modified to include a tangential velocity component. Experimental data matches that of the computational data, in which plasma ablation at an angle shows nearly half the ablation of plasma ablation at no angle. Fuel failure analysis of two NASA samples post-testing was conducted, and suggestions have been made for future materials fabrication processes. These studies, including the computational kinetic model at an angle and the ablation of the NASA sample, could be applied to an atmospheric reentry body, reentering at a ballistic trajectory at hypersonic velocities.

  8. Failure-Modes-And-Effects Analysis Of Software Logic

    NASA Technical Reports Server (NTRS)

    Garcia, Danny; Hartline, Thomas; Minor, Terry; Statum, David; Vice, David

    1996-01-01

    Rigorous analysis applied early in design effort. Method of identifying potential inadequacies and modes and effects of failures caused by inadequacies (failure-modes-and-effects analysis or "FMEA" for short) devised for application to software logic.

  9. Failure Mode and Effects Analysis (FMEA) Introductory Overview

    DTIC Science & Technology

    2012-06-14

    Failure Mode and Effects Analysis ( FMEA ) Introductory Overview TARDEC Systems Engineering Risk Management Team POC: Kadry Rizk or Gregor Ratajczak...2. REPORT TYPE Briefing Charts 3. DATES COVERED 01-05-2012 to 23-05-2012 4. TITLE AND SUBTITLE Failure Mode and Effects Analysis ( FMEA ) 5a...18 WELCOME Welcome to “An introductory overview of Failure Mode and Effects Analysis ( FMEA )”, A brief concerning the use and benefits of FMEA

  10. miRNAs as biomarkers for diagnosis of heart failure: A systematic review and meta-analysis.

    PubMed

    Yan, Hualin; Ma, Fan; Zhang, Yi; Wang, Chuan; Qiu, Dajian; Zhou, Kaiyu; Hua, Yimin; Li, Yifei

    2017-06-01

    With the rapid development of molecular biology, the kind of mircoRNA (miRNA) has been introduced into emerging role both in cardiac development and pathological procedure. Thus, we conduct this meta-analysis to find out the role of circulating miRNA as a biomarker in detecting heart failure. We searched PubMed, EMBASE, the Cochrane Central Register of Controlled Trials, and World Health Organization clinical trials registry center to identify relevant studies up to August 2016. We performed meta-analysis in a fixed/random-effect model using Meta-disc 1.4. We used STATA 14.0 to estimate the publication bias and meta-regression. Besides, we took use of SPSS 17.0 to evaluate variance between several groups. Information on true positive, false positive, false negative, and true negative, as well as the quality of research was extracted. We use results from 10 articles to analyze the pooled accuracy. The overall performance of total mixed miRNAs (TmiRs) detection was: pooled sensitivity, 0.74 (95% confidence interval [CI], 0.72 to 0.75); pooled specificity, 0.69 (95%CI, 0.67 to 0.71); and area under the summary receiver operating characteristic curves value (SROC), 0.7991. The miRNA-423-5p (miR-423-5p) detection was: pooled sensitivity, 0.81 (95%CI, 0.76 to 0.85); pooled specificity, 0.67 (95%CI, 0.61 to 0.73); and SROC, 0.8600. However, taken the same patients population, we extracted the data of BNP for detecting heart failure and performed meta-analysis with acceptable SROC as 0.9291. Among the variance analysis, the diagnostic performance of miR-423-5p claimed significant advantages of other pooled results. However, the combination of miRNAs and BNP could increase the accuracy of detecting of heart failure. Unfortunately, there was no dramatic advantage of miR-423-5p compared to BNP protocol. Despite interstudy variability, the performance test of miRNA for detecting heart failure revealed that miR-423-5p demonstrated the potential to be a biomarker. However, other miRNAs were not able to provide enough evidence on promising diagnostic value for heart failure based on the current data. Moreover, the combination of miRNAs and BNP could work as a better method to detection. Unfortunately, BNP was still the most convinced biomarker for such disease.

  11. An improved approach for flight readiness certification: Methodology for failure risk assessment and application examples. Volume 2: Software documentation

    NASA Technical Reports Server (NTRS)

    Moore, N. R.; Ebbeler, D. H.; Newlin, L. E.; Sutharshana, S.; Creager, M.

    1992-01-01

    An improved methodology for quantitatively evaluating failure risk of spaceflight systems to assess flight readiness and identify risk control measures is presented. This methodology, called Probabilistic Failure Assessment (PFA), combines operating experience from tests and flights with engineering analysis to estimate failure risk. The PFA methodology is of particular value when information on which to base an assessment of failure risk, including test experience and knowledge of parameters used in engineering analyses of failure phenomena, is expensive or difficult to acquire. The PFA methodology is a prescribed statistical structure in which engineering analysis models that characterize failure phenomena are used conjointly with uncertainties about analysis parameters and/or modeling accuracy to estimate failure probability distributions for specific failure modes, These distributions can then be modified, by means of statistical procedures of the PFA methodology, to reflect any test or flight experience. Conventional engineering analysis models currently employed for design of failure prediction are used in this methodology. The PFA methodology is described and examples of its application are presented. Conventional approaches to failure risk evaluation for spaceflight systems are discussed, and the rationale for the approach taken in the PFA methodology is presented. The statistical methods, engineering models, and computer software used in fatigue failure mode applications are thoroughly documented.

  12. An improved approach for flight readiness certification: Methodology for failure risk assessment and application examples, volume 1

    NASA Technical Reports Server (NTRS)

    Moore, N. R.; Ebbeler, D. H.; Newlin, L. E.; Sutharshana, S.; Creager, M.

    1992-01-01

    An improved methodology for quantitatively evaluating failure risk of spaceflight systems to assess flight readiness and identify risk control measures is presented. This methodology, called Probabilistic Failure Assessment (PFA), combines operating experience from tests and flights with engineering analysis to estimate failure risk. The PFA methodology is of particular value when information on which to base an assessment of failure risk, including test experience and knowledge of parameters used in engineering analyses of failure phenomena, is expensive or difficult to acquire. The PFA methodology is a prescribed statistical structure in which engineering analysis models that characterize failure phenomena are used conjointly with uncertainties about analysis parameters and/or modeling accuracy to estimate failure probability distributions for specific failure modes. These distributions can then be modified, by means of statistical procedures of the PFA methodology, to reflect any test or flight experience. Conventional engineering analysis models currently employed for design of failure prediction are used in this methodology. The PFA methodology is described and examples of its application are presented. Conventional approaches to failure risk evaluation for spaceflight systems are discussed, and the rationale for the approach taken in the PFA methodology is presented. The statistical methods, engineering models, and computer software used in fatigue failure mode applications are thoroughly documented.

  13. A Comprehensive Analysis of the Current Status and Unmet Needs in Kidney Transplantation in Southeast Asia

    PubMed Central

    Chan-on, Chitranon; Sarwal, Minnie M.

    2017-01-01

    To address the unmet needs in the face of a growing demand for end-stage renal failure management and kidney transplantation in Asia, we have conducted a critical analysis of published literature and national registries to evaluate clinical outcomes and the rates of organ donation in Southeast Asia and the challenges facing these regions with regards to regulation, choice of donor source, and funding. Based on the available data, suggestions are proposed for an advancement of rates of organ donation and access, with emphasis on improved regulation and public education. PMID:28691007

  14. Weighted Fuzzy Risk Priority Number Evaluation of Turbine and Compressor Blades Considering Failure Mode Correlations

    NASA Astrophysics Data System (ADS)

    Gan, Luping; Li, Yan-Feng; Zhu, Shun-Peng; Yang, Yuan-Jian; Huang, Hong-Zhong

    2014-06-01

    Failure mode, effects and criticality analysis (FMECA) and Fault tree analysis (FTA) are powerful tools to evaluate reliability of systems. Although single failure mode issue can be efficiently addressed by traditional FMECA, multiple failure modes and component correlations in complex systems cannot be effectively evaluated. In addition, correlated variables and parameters are often assumed to be precisely known in quantitative analysis. In fact, due to the lack of information, epistemic uncertainty commonly exists in engineering design. To solve these problems, the advantages of FMECA, FTA, fuzzy theory, and Copula theory are integrated into a unified hybrid method called fuzzy probability weighted geometric mean (FPWGM) risk priority number (RPN) method. The epistemic uncertainty of risk variables and parameters are characterized by fuzzy number to obtain fuzzy weighted geometric mean (FWGM) RPN for single failure mode. Multiple failure modes are connected using minimum cut sets (MCS), and Boolean logic is used to combine fuzzy risk priority number (FRPN) of each MCS. Moreover, Copula theory is applied to analyze the correlation of multiple failure modes in order to derive the failure probabilities of each MCS. Compared to the case where dependency among multiple failure modes is not considered, the Copula modeling approach eliminates the error of reliability analysis. Furthermore, for purpose of quantitative analysis, probabilities importance weight from failure probabilities are assigned to FWGM RPN to reassess the risk priority, which generalize the definition of probability weight and FRPN, resulting in a more accurate estimation than that of the traditional models. Finally, a basic fatigue analysis case drawn from turbine and compressor blades in aeroengine is used to demonstrate the effectiveness and robustness of the presented method. The result provides some important insights on fatigue reliability analysis and risk priority assessment of structural system under failure correlations.

  15. Failure behavior of plasma-sprayed HAp coating on commercially pure titanium substrate in simulated body fluid (SBF) under bending load.

    PubMed

    Laonapakul, Teerawat; Rakngarm Nimkerdphol, Achariya; Otsuka, Yuichi; Mutoh, Yoshiharu

    2012-11-01

    Four point bending tests with acoustic emission (AE) monitoring were conducted for evaluating failure behavior of the plasma-sprayed hydroxyapatite (HAp) top coat on commercially pure titanium (cp-Ti) plate with and without mixed HAp/Ti bond coat. Effect of immersion in simulated body fluid (SBF) on failure behavior of the coated specimen was also investigated by immersing the specimen in SBF. The AE patterns obtained from the bending test of the HAp coating specimens after a week immersion in SBF clearly showed the earlier stage of delamination and spallation of the coating layer compared to those without immersion in SBF. It was also found that the bond coating improved failure resistance of the HAp coating specimen compared to that without the bond coat. Four point bend fatigue tests under ambient and SBF environments were also conducted with AE monitoring during the entire fatigue test for investigating the influence of SBF environment on fatigue failure behavior of the HAp coating specimen with the mixed HAp/Ti bond coat. The specimens tested at a stress amplitude of 120 MPa under both ambient and SBF environments could survive up to 10⁷ cycles without spallation of HAp coating layer. The specimens tested under SBF environment and those tested under ambient environment after immersion in SBF showed shorter fatigue life compared to those tested under ambient environment without SBF immersion. Micro-cracks nucleated in the coating layer in the early stage of fatigue life and then propagated into the cp-Ti substrate in the intermediate stage, which unstably propagated to failure in the final stage. It was found from the XRD analysis that the dissolution of the co-existing phases and the precipitation of the HAp phase were taken place during immersion in SBF. During this process, the co-existing phases disappeared from the coating layer and the HAp phase fully occupied the coating layer. The degradation of bending strength and fatigue life of the HAp coating specimens tested under SBF environment would be induced by dissolution of the co-existing phases from the coating layer during immersion in SBF. Copyright © 2012 Elsevier Ltd. All rights reserved.

  16. Mechanical Behavior of Steel Fiber-Reinforced Concrete Beams Bonded with External Carbon Fiber Sheets

    PubMed Central

    Gribniak, Viktor; Tamulenas, Vytautas; Ng, Pui-Lam; Arnautov, Aleksandr K.; Gudonis, Eugenijus; Misiunaite, Ieva

    2017-01-01

    This study investigates the mechanical behavior of steel fiber-reinforced concrete (SFRC) beams internally reinforced with steel bars and externally bonded with carbon fiber-reinforced polymer (CFRP) sheets fixed by adhesive and hybrid jointing techniques. In particular, attention is paid to the load resistance and failure modes of composite beams. The steel fibers were used to avoiding the rip-off failure of the concrete cover. The CFRP sheets were fixed to the concrete surface by epoxy adhesive as well as combined with various configurations of small-diameter steel pins for mechanical fastening to form a hybrid connection. Such hybrid jointing techniques were found to be particularly advantageous in avoiding brittle debonding failure, by promoting progressive failure within the hybrid joints. The use of CFRP sheets was also effective in suppressing the localization of the discrete cracks. The development of the crack pattern was monitored using the digital image correlation method. As revealed from the image analyses, with an appropriate layout of the steel pins, brittle failure of the concrete-carbon fiber interface could be effectively prevented. Inverse analysis of the moment-curvature diagrams was conducted, and it was found that a simplified tension-stiffening model with a constant residual stress level at 90% of the strength of the SFRC is adequate for numerically simulating the deformation behavior of beams up to the debonding of the CFRP sheets. PMID:28773024

  17. Mechanical Behavior of Steel Fiber-Reinforced Concrete Beams Bonded with External Carbon Fiber Sheets.

    PubMed

    Gribniak, Viktor; Tamulenas, Vytautas; Ng, Pui-Lam; Arnautov, Aleksandr K; Gudonis, Eugenijus; Misiunaite, Ieva

    2017-06-17

    This study investigates the mechanical behavior of steel fiber-reinforced concrete (SFRC) beams internally reinforced with steel bars and externally bonded with carbon fiber-reinforced polymer (CFRP) sheets fixed by adhesive and hybrid jointing techniques. In particular, attention is paid to the load resistance and failure modes of composite beams. The steel fibers were used to avoiding the rip-off failure of the concrete cover. The CFRP sheets were fixed to the concrete surface by epoxy adhesive as well as combined with various configurations of small-diameter steel pins for mechanical fastening to form a hybrid connection. Such hybrid jointing techniques were found to be particularly advantageous in avoiding brittle debonding failure, by promoting progressive failure within the hybrid joints. The use of CFRP sheets was also effective in suppressing the localization of the discrete cracks. The development of the crack pattern was monitored using the digital image correlation method. As revealed from the image analyses, with an appropriate layout of the steel pins, brittle failure of the concrete-carbon fiber interface could be effectively prevented. Inverse analysis of the moment-curvature diagrams was conducted, and it was found that a simplified tension-stiffening model with a constant residual stress level at 90% of the strength of the SFRC is adequate for numerically simulating the deformation behavior of beams up to the debonding of the CFRP sheets.

  18. Material failure modelling in metals at high strain rates

    NASA Astrophysics Data System (ADS)

    Panov, Vili

    2005-07-01

    Plate impact tests have been conducted on the OFHC Cu using single-stage gas gun. Using stress gauges, which were supported with PMMA blocks on the back of the target plates, stress-time histories have been recorded. After testing, micro structural observations of the softly recovered OFHC Cu spalled specimen were carried out and evolution of damage has been examined. To account for the physical mechanisms of failure, the concept that thermal activation in material separation during fracture processes has been adopted as basic mechanism for this material failure model development. With this basic assumption, the proposed model is compatible with the Mechanical Threshold Stress model and therefore in this development it was incorporated into the MTS material model in DYNA3D. In order to analyse proposed criterion a series of FE simulations have been performed for OFHC Cu. The numerical analysis results clearly demonstrate the ability of the model to predict the spall process and experimentally observed tensile damage and failure. It is possible to simulate high strain rate deformation processes and dynamic failure in tension for wide range of temperature. The proposed cumulative criterion, introduced in the DYNA3D code, is able to reproduce the ``pull-back'' stresses of the free surface caused by creation of the internal spalling, and enables one to analyse numerically the spalling over a wide range of impact velocities.

  19. Introduction of the TEAM-HF Costing Tool: A User-Friendly Spreadsheet Program to Estimate Costs of Providing Patient-Centered Interventions

    PubMed Central

    Reed, Shelby D.; Li, Yanhong; Kamble, Shital; Polsky, Daniel; Graham, Felicia L.; Bowers, Margaret T.; Samsa, Gregory P.; Paul, Sara; Schulman, Kevin A.; Whellan, David J.; Riegel, Barbara J.

    2011-01-01

    Background Patient-centered health care interventions, such as heart failure disease management programs, are under increasing pressure to demonstrate good value. Variability in costing methods and assumptions in economic evaluations of such interventions limit the comparability of cost estimates across studies. Valid cost estimation is critical to conducting economic evaluations and for program budgeting and reimbursement negotiations. Methods and Results Using sound economic principles, we developed the Tools for Economic Analysis of Patient Management Interventions in Heart Failure (TEAM-HF) Costing Tool, a spreadsheet program that can be used by researchers or health care managers to systematically generate cost estimates for economic evaluations and to inform budgetary decisions. The tool guides users on data collection and cost assignment for associated personnel, facilities, equipment, supplies, patient incentives, miscellaneous items, and start-up activities. The tool generates estimates of total program costs, cost per patient, and cost per week and presents results using both standardized and customized unit costs for side-by-side comparisons. Results from pilot testing indicated that the tool was well-formatted, easy to use, and followed a logical order. Cost estimates of a 12-week exercise training program in patients with heart failure were generated with the costing tool and were found to be consistent with estimates published in a recent study. Conclusions The TEAM-HF Costing Tool could prove to be a valuable resource for researchers and health care managers to generate comprehensive cost estimates of patient-centered interventions in heart failure or other conditions for conducting high-quality economic evaluations and making well-informed health care management decisions. PMID:22147884

  20. Interventions for Dental Implant Placement in Atrophic Edentulous Mandibles: Vertical Bone Augmentation and Alternative Treatments. A Meta-Analysis of Randomized Clinical Trials.

    PubMed

    Camps-Font, Octavi; Burgueño-Barris, Genís; Figueiredo, Rui; Jung, Ronald E; Gay-Escoda, Cosme; Valmaseda-Castellón, Eduard

    2016-12-01

    The purpose of the current study is to assess which vertical bone augmentation techniques are most effective for restoring atrophic posterior areas of the mandible with dental implants and compare these procedures with alternative treatments. Electronic literature searches in PubMed (MEDLINE), Ovid, and the Cochrane Library were conducted to identify all relevant articles published up to July 1, 2015. Eligibility was based on inclusion criteria, and quality assessments were conducted. The primary outcome variables were implant and prosthetic failure. After data extraction, meta-analyses were performed. Out of 527 potentially eligible papers, 14 randomized clinical trials were included. Out of these 14 studies, four trials assessed short implants (5 to 8 mm) as an alternative to vertical bone augmentation in sites with a residual ridge height of 5 to 8 mm. No statistically significant differences were found in implant (odds ratio [OR]: 1.02; 95% confidence interval [CI]: 0.31 to 3.31; P = 0.98; I 2 : 0%) or prosthetic failure (OR: 0.64; 95% CI: 0.21 to 1.96; P = 0.43; I 2 : 0%) after 12 months of loading. However, complications at treated sites increased with the augmentation procedures (OR: 8.33; 95% CI: 3.85 to 20.0; P <0.001; I 2 : 0%). There was no evidence of any vertical augmentation procedure being of greater benefit than any other for the primary outcomes (implant and prosthetic failure). Short implants in the posterior area of the mandible seem to be preferable to vertical augmentation procedures, which present similar implant and prosthetic failure rates but greater morbidity. All the vertical augmentation technique comparisons showed similar intergroup results.

  1. Development of an economic model to assess the cost-effectiveness of hawthorn extract as an adjunct treatment for heart failure in Australia

    PubMed Central

    Ford, Emily; Adams, Jon; Graves, Nicholas

    2012-01-01

    Objective An economic model was developed to evaluate the cost-effectiveness of hawthorn extract as an adjunctive treatment for heart failure in Australia. Methods A Markov model of chronic heart failure was developed to compare the costs and outcomes of standard treatment and standard treatment with hawthorn extract. Health states were defined by the New York Heart Association (NYHA) classification system and death. For any given cycle, patients could remain in the same NYHA class, experience an improvement or deterioration in NYHA class, be hospitalised or die. Model inputs were derived from the published medical literature, and the output was quality-adjusted life years (QALYs). Probabilistic sensitivity analysis was conducted. The expected value of perfect information (EVPI) and the expected value of partial perfect information (EVPPI) were conducted to establish the value of further research and the ideal target for such research. Results Hawthorn extract increased costs by $1866.78 and resulted in a gain of 0.02 QALYs. The incremental cost-effectiveness ratio was $85 160.33 per QALY. The cost-effectiveness acceptability curve indicated that at a threshold of $40 000 the new treatment had a 0.29 probability of being cost-effective. The average incremental net monetary benefit (NMB) was −$1791.64, the average NMB for the standard treatment was $92 067.49, and for hawthorn extract $90 275.84. Additional research is potentially cost-effective if research is not proposed to cost more than $325 million. Utilities form the most important target parameter group for further research. Conclusions Hawthorn extract is not currently considered to be cost-effective in as an adjunctive treatment for heart failure in Australia. Further research in the area of utilities is warranted. PMID:22942231

  2. Development of an economic model to assess the cost-effectiveness of hawthorn extract as an adjunct treatment for heart failure in Australia.

    PubMed

    Ford, Emily; Adams, Jon; Graves, Nicholas

    2012-01-01

    An economic model was developed to evaluate the cost-effectiveness of hawthorn extract as an adjunctive treatment for heart failure in Australia. A Markov model of chronic heart failure was developed to compare the costs and outcomes of standard treatment and standard treatment with hawthorn extract. Health states were defined by the New York Heart Association (NYHA) classification system and death. For any given cycle, patients could remain in the same NYHA class, experience an improvement or deterioration in NYHA class, be hospitalised or die. Model inputs were derived from the published medical literature, and the output was quality-adjusted life years (QALYs). Probabilistic sensitivity analysis was conducted. The expected value of perfect information (EVPI) and the expected value of partial perfect information (EVPPI) were conducted to establish the value of further research and the ideal target for such research. Hawthorn extract increased costs by $1866.78 and resulted in a gain of 0.02 QALYs. The incremental cost-effectiveness ratio was $85 160.33 per QALY. The cost-effectiveness acceptability curve indicated that at a threshold of $40 000 the new treatment had a 0.29 probability of being cost-effective. The average incremental net monetary benefit (NMB) was -$1791.64, the average NMB for the standard treatment was $92 067.49, and for hawthorn extract $90 275.84. Additional research is potentially cost-effective if research is not proposed to cost more than $325 million. Utilities form the most important target parameter group for further research. Hawthorn extract is not currently considered to be cost-effective in as an adjunctive treatment for heart failure in Australia. Further research in the area of utilities is warranted.

  3. Cost-effectiveness of early compared to late inhaled nitric oxide therapy in near-term infants.

    PubMed

    Armstrong, Edward P; Dhanda, Rahul

    2010-12-01

    The purpose of this study was to determine the cost-effectiveness of early versus late inhaled nitric oxide (INO) therapy in neonates with hypoxic respiratory failure initially managed on conventional mechanical ventilation. A decision analytic model was created to compare the use of early INO compared to delayed INO for neonates receiving mechanical ventilation due to hypoxic respiratory failure. The perspective of the model was that of a hospital. Patients who did not respond to either early or delayed INO were assumed to have been treated with extracorporeal membrane oxygenation (ECMO). The effectiveness measure was defined as a neonate discharged alive without requiring ECMO therapy. A Monte Carlo simulation of 10,000 cases was conducted using first and second order probabilistic analysis. Direct medical costs that differed between early versus delayed INO treatment were estimated until time to hospital discharge. The proportion of successfully treated patients and costs were determined from the probabilistic sensitivity analysis. The mean (± SD) effectiveness rate for early INO was 0.75 (± 0.08) and 0.61 (± 0.09) for delayed INO. The mean hospital cost for early INO was $21,462 (± $2695) and $27,226 (± $3532) for delayed INO. In 87% of scenarios, early INO dominated delayed INO by being both more effective and less costly. The acceptability curve between products demonstrated that early INO had over a 90% probability of being the most cost-effective treatment across a wide range of willingness to pay values. This analysis indicated that early INO therapy was cost-effective in neonates with hypoxic respiratory failure requiring mechanical ventilation compared to delayed INO by reducing the probability of developing severe hypoxic respiratory failure. There was a 90% or higher probability that early INO was more cost-effective than delayed INO across a wide range of willingness to pay values in this analysis.

  4. Modelling river bank retreat by combining fluvial erosion, seepage and mass failure

    NASA Astrophysics Data System (ADS)

    Dapporto, S.; Rinaldi, M.

    2003-04-01

    Streambank erosion processes contribute significantly to the sediment yielded from a river system and represent an important issue in the contexts of soil degradation and river management. Bank retreat is controlled by a complex interaction of hydrologic, geotechnical, and hydraulic processes. The capability of modelling these different components allows for a full reconstruction and comprehension of the causes and rates of bank erosion. River bank retreat during a single flow event has been modelled by combining simulation of fluvial erosion, seepage, and mass failures. The study site, along the Sieve River (Central Italy), has been subject to extensive researches, including monitoring of pore water pressures for a period of 4 years. The simulation reconstructs fairly faithfully the observed changes, and is used to: a) test the potentiality and discuss advantages and limitations of such type of methodology for modelling bank retreat; c) quantify the contribution and mutual role of the different processes determining bank retreat. The hydrograph of the event is divided in a series of time steps. Modelling of the riverbank retreat includes for each step the following components: a) fluvial erosion and consequent changes in bank geometry; b) finite element seepage analysis; c) stability analysis by limit equilibrium method. Direct fluvial shear erosion is computed using empirically derived relationships expressing lateral erosion rate as a function of the excess of shear stress to the critical entrainment value for the different materials along the bank profile. Lateral erosion rate has been calibrated on the basis of the total bank retreat measured by digital terrestrial photogrammetry. Finite element seepage analysis is then conducted to reconstruct the saturated and unsaturated flow within the bank and the pore water pressure distribution for each time step. The safety factor for mass failures is then computed, using the pore water pressure distribution obtained by the seepage analysis, and the geometry of the upper bank is modified in case of failure.

  5. The incidence of ischemic stroke in chronic heart failure: a meta-analysis.

    PubMed

    Witt, Brandi J; Gami, Apoor S; Ballman, Karla V; Brown, Robert D; Meverden, Ryan A; Jacobsen, Stephen J; Roger, Véronique L

    2007-08-01

    There is marked variability in the reported stroke rates among persons with heart failure (HF). We performed a meta-analysis to provide summary estimates of the stroke rate in HF and to explain heterogeneity in the existing literature. We will summarize the ischemic stroke rate at various time points during follow-up among adults with chronic heart failure. A systematic review of the electronic literature in Medline and PubMed as well as hand searching of the reference lists of identified articles and of the meeting abstracts for the 1995-2004 American College of Cardiology and American Heart Association scientific sessions was performed to identify qualifying studies. Articles were included if they included a population with chronic HF and reported the number (or percent) of persons with HF who experienced an ischemic stroke during follow-up. Studies were excluded if the study population included > or = 50% of persons with acute (postmyocardial infarction) HF, or if > or = 50% of the study population required artificial support with a ventricular assist device or parenteral inotropic medications. Case reports, case series, and nonoriginal research articles were not included. Determination of study eligibility and data extraction were conducted by 2 independent reviewers using standardized forms. Results are reported as stroke rate per 1000 cases of HF, with 95% Poisson confidence intervals. Pooled estimates of the stroke rate were calculated with fixed and random effects models. Heterogeneity was explored according to a priori specified subgroup analyses. Overall, 26 studies met inclusion criteria. Eighteen of every 1000 persons suffered a stroke during the first year after the diagnosis of HF. The stroke rate increased to a maximum of 47.4 per 1000 at 5 years. Studies with fewer women, those conducted in 1990 or earlier, and cohort studies reported higher stroke rates than studies with more women, those conducted after 1990, and clinical trials. Stroke is an important complication among persons with HF. Variability among reported stroke rates can be explained in part by differences in study design, patient population, and HF standards of care at the time of the study. Despite the heterogeneity in reported stroke rates, this meta-analysis shows that stroke prevention in HF represents an opportunity to prevent morbidity and save many lives in this highly fatal disease.

  6. Analyses of Transistor Punchthrough Failures

    NASA Technical Reports Server (NTRS)

    Nicolas, David P.

    1999-01-01

    The failure of two transistors in the Altitude Switch Assembly for the Solid Rocket Booster followed by two additional failures a year later presented a challenge to failure analysts. These devices had successfully worked for many years on numerous missions. There was no history of failures with this type of device. Extensive checks of the test procedures gave no indication for a source of the cause. The devices were manufactured more than twenty years ago and failure information on this lot date code was not readily available. External visual exam, radiography, PEID, and leak testing were performed with nominal results Electrical testing indicated nearly identical base-emitter and base-collector characteristics (both forward and reverse) with a low resistance short emitter to collector. These characteristics are indicative of a classic failure mechanism called punchthrough. In failure analysis punchthrough refers to an condition where a relatively low voltage pulse causes the device to conduct very hard producing localized areas of thermal runaway or "hot spots". At one or more of these hot spots, the excessive currents melt the silicon. Heavily doped emitter material diffuses through the base region to the collector forming a diffusion pipe shorting the emitter to base to collector. Upon cooling, an alloy junction forms between the pipe and the base region. Generally, the hot spot (punch-through site) is under the bond and no surface artifact is visible. The devices were delidded and the internal structures were examined microscopically. The gold emitter lead was melted on one device, but others had anomalies in the metallization around the in-tact emitter bonds. The SEM examination confirmed some anomalies to be cosmetic defects while other anomalies were artifacts of the punchthrough site. Subsequent to these analyses, the contractor determined that some irregular testing procedures occurred at the time of the failures heretofore unreported. These testing irregularities involved the use of a breakout box and were the likely cause of the failures. There was no evidence to suggest a generic failure mechanism was responsible for the failure of these transistors.

  7. Progressive Failure Analysis of Composite Stiffened Panels

    NASA Technical Reports Server (NTRS)

    Bednarcyk, Brett A.; Yarrington, Phillip W.; Collier, Craig S.; Arnold, Steven M.

    2006-01-01

    A new progressive failure analysis capability for stiffened composite panels has been developed based on the combination of the HyperSizer stiffened panel design/analysis/optimization software with the Micromechanics Analysis Code with Generalized Method of Cells (MAC/GMC). MAC/GMC discretizes a composite material s microstructure into a number of subvolumes and solves for the stress and strain state in each while providing the homogenized composite properties as well. As a result, local failure criteria may be employed to predict local subvolume failure and the effects of these local failures on the overall composite response. When combined with HyperSizer, MAC/GMC is employed to represent the ply level composite material response within the laminates that constitute a stiffened panel. The effects of local subvolume failures can then be tracked as loading on the stiffened panel progresses. Sample progressive failure results are presented at both the composite laminate and the composite stiffened panel levels. Deformation and failure model predictions are compared with experimental data from the World Wide Failure Exercise for AS4/3501-6 graphite/epoxy laminates.

  8. Does natriuretic peptide monitoring improve outcomes in heart failure patients? A systematic review and meta-analysis.

    PubMed

    Khan, Muhammad Shahzeb; Siddiqi, Tariq Jamal; Usman, Muhammad Shariq; Sreenivasan, Jayakumar; Fugar, Setri; Riaz, Haris; Murad, M H; Mookadam, Farouk; Figueredo, Vincent M

    2018-07-15

    Current guidelines do not support the use of serial natriuretic peptide (NP) monitoring for heart failure with preserved (HFpEF) or reduced ejection fraction (HFrEF) treatment, despite some studies showing benefit. We conducted an updated meta-analysis to address whether medical therapy in HFpEF or HFrEF should be titrated according to NP levels. MEDLINE, Scopus and Cochrane CENTRAL databases were searched for randomized controlled trials (RCTs) comparing NP versus guideline directed titration in HF patients through December 2017. The key outcomes of interest were mortality, HF hospitalizations and all-cause hospitalizations. Risk ratios and 95% confidence intervals were pooled using random effects model. Sub-group analyses were performed for type of NP used, average age and acute or chronic HF. Eighteen trials including 5116 patients were included. Meta-analysis showed no significant difference between the NP-guided arm versus guideline directed titration in all-cause mortality (RR = 0.91 [0.81, 1.03]; p = 0.13), HF hospitalizations (RR = 0.81 [0.65, 1.01]; p = 0.06), and all cause hospitalizations (RR = 0.93 [0.86, 1.01]; p = 0.09). The results were consistent upon subgroup analysis by biomarker type (NT-proBNP or BNP) and type of heart failure (acute or chronic and HFrEF or HFpEF). Sub-group analysis suggested that NP-guided treatment was associated with decreased all-cause hospitalizations in patients younger than 72 years of age. The available evidence suggests that NP-guided therapy provides no additional benefit over guideline directed therapy in terms of all-cause mortality and HF-related hospitalizations in acute or chronic HF patients, regardless of their ejection fraction. Copyright © 2018 Elsevier B.V. All rights reserved.

  9. Risk Based Reliability Centered Maintenance of DOD Fire Protection Systems

    DTIC Science & Technology

    1999-01-01

    2.2.3 Failure Mode and Effect Analysis ( FMEA )............................ 2.2.4 Failure Mode Risk Characterization...Step 2 - System functions and functional failures definition Step 3 - Failure mode and effect analysis ( FMEA ) Step 4 - Failure mode risk...system). The Interface Location column identifies the location where the FMEA of the fire protection system began or stopped. For example, for the fire

  10. Fracture characteristics of balloon films

    NASA Technical Reports Server (NTRS)

    Portanova, Marc A.

    1989-01-01

    An attempt was made to determine the failure modes of high altitude scientific balloons through an investigation of the fracture characteristics of the thin polyethylene films. Two films were the subject of the evaluation, Winzen Int.'s Stratafilm SF-85 and Raven Industries' Astro-E. Research began with an investigation of the film's cold brittleness point and it's effect on the ultimate strength and elasticity of the polyethylene film. A series of preliminary investigations were conducted to develop an understanding of the material characteristics. The primary focus of this investigation was on the notch sensitivity of the films. Simple stress strain tests were also conducted to enable analysis employing fracture toughness parameters. Studies were conducted on both film types at 23 C (room temperature), -60 C, -90 C, and -120 C.

  11. Space Shuttle Stiffener Ring Foam Failure Analysis, a Non-Conventional Approach

    NASA Technical Reports Server (NTRS)

    Howard, Philip M.

    2015-01-01

    The Space Shuttle Program made use of the excellent properties of rigid polyurethane foam for cryogenic tank insulation and as structural protection on the solid rocket boosters. When foam applications de-bond, classical methods of failure analysis did not provide root cause of the failure of the foam. Realizing that foam is the ideal media to document and preserve its own mode of failure, thin sectioning was seen as a logical approach for foam failure analysis to observe the three dimensional morphology of the foam cells. The cell foam morphology provided a much greater understanding of the failure modes than previously achieved.

  12. 1001518

    NASA Image and Video Library

    2010-09-01

    DEVELOPMENT TESTING BEING CONDUCTED AT THE REQUEST OF THE MSFC DYNAMICS, LOADS, AND STRENGTH BRANCH (EV31) TO STUDY THE FAILURE BEHAVIOR OF FASTENERS SUBJECTED TO COMBINED SHEAR AND TENSION LOADING. THE DATA FROM THIS TESTING WILL BE USED TO DEVELOP APPROPRIATE STRUCTURAL ANALYSIS METHODS AS PART OF A FASTENER STANDARDS EFFORT SPONSORED BY THE NASA ENGINEERING SAFETY CENTER (NESC). THE TEST FIXTURE WAS DESIGNED AND FABRICATED THROUGH THE MSFC MECHANICAL FABRICATION BRANCH (ES23). THE TESTING ORGANIZATION IS THE MSFC MATERIALS TEST BRANCH (EM10).

  13. 1001519

    NASA Image and Video Library

    2010-09-01

    DEVELOPMENT TESTING BEING CONDUCTED AT THE REQUEST OF THE MSFC DYNAMICS, LOADS, AND STRENGTH BRANCH (EV31) TO STUDY THE FAILURE BEHAVIOR OF FASTENERS SUBJECTED TO COMBINED SHEAR AND TENSION LOADING. THE DATA FROM THIS TESTING WILL BE USED TO DEVELOP APPROPRIATE STRUCTURAL ANALYSIS METHODS AS PART OF A FASTENER STANDARDS EFFORT SPONSORED BY THE NASA ENGINEERING SAFETY CENTER (NESC). THE TEST FIXTURE WAS DESIGNED AND FABRICATED THROUGH THE MSFC MECHANICAL FABRICATION BRANCH (ES23). THE TESTING ORGANIZATION IS THE MSFC MATERIALS TEST BRANCH (EM10).

  14. 1001520

    NASA Image and Video Library

    2010-09-01

    DEVELOPMENT TESTING BEING CONDUCTED AT THE REQUEST OF THE MSFC DYNAMICS, LOADS, AND STRENGTH BRANCH (EV31) TO STUDY THE FAILURE BEHAVIOR OF FASTENERS SUBJECTED TO COMBINED SHEAR AND TENSION LOADING. THE DATA FROM THIS TESTING WILL BE USED TO DEVELOP APPROPRIATE STRUCTURAL ANALYSIS METHODS AS PART OF A FASTENER STANDARDS EFFORT SPONSORED BY THE NASA ENGINEERING SAFETY CENTER (NESC). THE TEST FIXTURE WAS DESIGNED AND FABRICATED THROUGH THE MSFC MECHANICAL FABRICATION BRANCH (ES23). THE TESTING ORGANIZATION IS THE MSFC MATERIALS TEST BRANCH (EM10).

  15. 1001521

    NASA Image and Video Library

    2010-09-01

    DEVELOPMENT TESTING BEING CONDUCTED AT THE REQUEST OF THE MSFC DYNAMICS, LOADS, AND STRENGTH BRANCH (EV31) TO STUDY THE FAILURE BEHAVIOR OF FASTENERS SUBJECTED TO COMBINED SHEAR AND TENSION LOADING. THE DATA FROM THIS TESTING WILL BE USED TO DEVELOP APPROPRIATE STRUCTURAL ANALYSIS METHODS AS PART OF A FASTENER STANDARDS EFFORT SPONSORED BY THE NASA ENGINEERING SAFETY CENTER (NESC). THE TEST FIXTURE WAS DESIGNED AND FABRICATED THROUGH THE MSFC MECHANICAL FABRICATION BRANCH (ES23). THE TESTING ORGANIZATION IS THE MSFC MATERIALS TEST BRANCH (EM10).

  16. Dynamic Fracture Simulations of Explosively Loaded Cylinders

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Arthur, Carly W.; Goto, D. M.

    2015-11-30

    This report documents the modeling results of high explosive experiments investigating dynamic fracture of steel (AerMet® 100 alloy) cylinders. The experiments were conducted at Lawrence Livermore National Laboratory (LLNL) during 2007 to 2008 [10]. A principal objective of this study was to gain an understanding of dynamic material failure through the analysis of hydrodynamic computer code simulations. Two-dimensional and three-dimensional computational cylinder models were analyzed using the ALE3D multi-physics computer code.

  17. [Cost-effectiveness analysis of renal replacement therapies: how should we design research on these interventions in Brazil?].

    PubMed

    Sancho, Leyla Gomes; Dain, Sulamis

    2008-06-01

    This study aims to contribute to the discussion on the possibility of applying health economics assessment, specifically the cost-effectiveness technique, to renal replacement therapies for end-stage renal failure. A review was conducted on the interventions and their alternative courses from the perspective of the various methodological proposals in the literature, considering the availability of data and information in Brazil to back this type of research.

  18. Microcircuit failure analysis using the SEM. [Scanning Electron Microscopes

    NASA Technical Reports Server (NTRS)

    Nicolas, D. P.

    1974-01-01

    The scanning electron microscope adds a new dimension to the knowledge that can be obtained from a failed microcircuit. When used with conventional techniques, SEM assists and clarifies the analysis, but it does not replace light microscopy. The most advantageous features for microcircuit analysis are long working distances and great depth of field. Manufacturer related failure modes of microcircuits are metallization defects, poor bonding, surface and particle contamination, and design and fabrication faults. User related failure modes are caused by abuse, such as overstress. The Physics of Failure Procedure followed by the Astrionics Laboratory in failure analysis is described, which is designed to obtain maximum information available from each step.

  19. Thermal-Structural Analysis of PICA Tiles for Solar Tower Test

    NASA Technical Reports Server (NTRS)

    Agrawal, Parul; Empey, Daniel M.; Squire, Thomas H.

    2009-01-01

    Thermal protection materials used in spacecraft heatshields are subjected to severe thermal and mechanical loading environments during re-entry into earth atmosphere. In order to investigate the reliability of PICA tiles in the presence of high thermal gradients as well as mechanical loads, the authors designed and conducted solar-tower tests. This paper presents the design and analysis work for this tests series. Coupled non-linear thermal-mechanical finite element analyses was conducted to estimate in-depth temperature distribution and stress contours for various cases. The first set of analyses performed on isolated PICA tile showed that stresses generated during the tests were below the PICA allowable limit and should not lead to any catastrophic failure during the test. The tests results were consistent with analytical predictions. The temperature distribution and magnitude of the measured strains were also consistent with predicted values. The second test series is designed to test the arrayed PICA tiles with various gap-filler materials. A nonlinear contact method is used to model the complex geometry with various tiles. The analyses for these coupons predict the stress contours in PICA and inside gap fillers. Suitable mechanical loads for this architecture will be predicted, which can be applied during the test to exceed the allowable limits and demonstrate failure modes. Thermocouple and strain-gauge data obtained from the solar tower tests will be used for subsequent analyses and validation of FEM models.

  20. Primary care-based multifaceted, interdisciplinary medical educational intervention for patients with systolic heart failure: lessons learned from a cluster randomised controlled trial.

    PubMed

    Peters-Klimm, Frank; Campbell, Stephen; Müller-Tasch, Thomas; Schellberg, Dieter; Gelbrich, Goetz; Herzog, Wolfgang; Szecsenyi, Joachim

    2009-08-13

    Chronic (systolic) heart failure (CHF) is a common and disabling condition. Adherence to evidence-based guidelines in primary care has been shown to improve health outcomes. The aim was to explore the impact of a multidisciplinary educational intervention for general practitioners (GPs) (Train the trainer = TTT) on patient and performance outcomes. This paper presents the key findings from the trial and discusses the lessons learned during the implementation of the TTT trial. Primary care practices were randomly assigned to the TTT intervention or to the control group. 37 GPs (18 TTT, 19 control) were randomised and 168 patients diagnosed with ascertained CHF (91 TTT, 77 control) were enrolled. GPs in the intervention group attended four meetings addressing clinical practice guidelines and pharmacotherapy feedback. The primary outcome was patient self-reported quality of life at seven months, using the SF-36 Physical Functioning scale. Secondary outcomes included other SF-36 scales, the Kansas City Cardiomyopathy Questionnaire (KCCQ), total mortality, heart failure hospital admissions, prescribing, depressive disorders (PHQ-9), behavioural change (European Heart Failure Self-Care Behaviour Scale), patient-perceived quality of care (EUROPEP) and improvement of heart failure using NT-proBNP-levels. Because recruitment targets were not achieved an exploratory analysis was conducted. There was high baseline achievement in both groups for many outcomes. At seven months, there were no significant mean difference between groups for the primary outcome measure (-3.3, 95%CI -9.7 to 3.1, p = 0.30). The only difference in secondary outcomes related to the prescribing of aldosterone antagonists by GPs in the intervention group, with significant between group differences at follow-up (42 vs. 24%, adjusted OR = 4.0, 95%CI 1.2-13; p = 0.02). The intervention did not change the primary outcome or most secondary outcomes. Recruitment targets were not achieved and the under-recruitment of practices and patients alongside a selection bias of participating GPs, prohibit definite conclusions, but the CI indicates a non-effectiveness of the intervention in this sample. We describe the lessons learned from conducting the trial for the future planning and conduct of confirmatory trials in primary care. ISRCTN08601529.

  1. Primary care-based multifaceted, interdisciplinary medical educational intervention for patients with systolic heart failure: lessons learned from a cluster randomised controlled trial

    PubMed Central

    Peters-Klimm, Frank; Campbell, Stephen; Müller-Tasch, Thomas; Schellberg, Dieter; Gelbrich, Goetz; Herzog, Wolfgang; Szecsenyi, Joachim

    2009-01-01

    Background Chronic (systolic) heart failure (CHF) is a common and disabling condition. Adherence to evidence-based guidelines in primary care has been shown to improve health outcomes. The aim was to explore the impact of a multidisciplinary educational intervention for general practitioners (GPs) (Train the trainer = TTT) on patient and performance outcomes. Methods This paper presents the key findings from the trial and discusses the lessons learned during the implementation of the TTT trial. Primary care practices were randomly assigned to the TTT intervention or to the control group. 37 GPs (18 TTT, 19 control) were randomised and 168 patients diagnosed with ascertained CHF (91 TTT, 77 control) were enrolled. GPs in the intervention group attended four meetings addressing clinical practice guidelines and pharmacotherapy feedback. The primary outcome was patient self-reported quality of life at seven months, using the SF-36 Physical Functioning scale. Secondary outcomes included other SF-36 scales, the Kansas City Cardiomyopathy Questionnaire (KCCQ), total mortality, heart failure hospital admissions, prescribing, depressive disorders (PHQ-9), behavioural change (European Heart Failure Self-Care Behaviour Scale), patient-perceived quality of care (EUROPEP) and improvement of heart failure using NT-proBNP-levels. Because recruitment targets were not achieved an exploratory analysis was conducted. Results There was high baseline achievement in both groups for many outcomes. At seven months, there were no significant mean difference between groups for the primary outcome measure (-3.3, 95%CI -9.7 to 3.1, p = 0.30). The only difference in secondary outcomes related to the prescribing of aldosterone antagonists by GPs in the intervention group, with significant between group differences at follow-up (42 vs. 24%, adjusted OR = 4.0, 95%CI 1.2–13; p = 0.02). Conclusion The intervention did not change the primary outcome or most secondary outcomes. Recruitment targets were not achieved and the under-recruitment of practices and patients alongside a selection bias of participating GPs, prohibit definite conclusions, but the CI indicates a non-effectiveness of the intervention in this sample. We describe the lessons learned from conducting the trial for the future planning and conduct of confirmatory trials in primary care. Trial registration ISRCTN08601529. PMID:19678944

  2. Childhood Conduct Problems and Young Adult Outcomes Among Women with Childhood ADHD

    PubMed Central

    Owens, Elizabeth B.; Hinshaw, Stephen P.

    2015-01-01

    We tested whether conduct problems predicted young adult functioning and psychiatric symptoms among women diagnosed with ADHD during childhood, in the context of three potential adolescent mediators: internalizing problems, peer rejection, and school failure and disciplinary problems. We controlled for childhood ADHD severity, IQ, and demographic factors, and in the mediational tests, for adolescent conduct problems. Data emanated from 140 participants in the Berkeley Girls with ADHD Longitudinal Study. We used bootstrapping methods to assess indirect effects (mediators). Both childhood (F1,118 change = 9.00, p = .003, R2 change = .069) and adolescent (F1,109 change = 10.41, p = .002, R2 change = .083) conduct problems were associated with worse overall functioning during young adulthood, controlling for initial ADHD severity, child IQ, and demographics. Results were similar when predicting psychiatric symptoms. Adolescent school failure and disciplinary problems mediated the relations between childhood conduct problems and both young-adult functioning and externalizing problems; adolescent internalizing problems and peer conflict mediated the relation between childhood conduct problems and young-adult internalizing problems. As is true for boys, childhood and adolescent conduct problems are associated with poor adult outcomes among girls with ADHD, with school failure and disciplinary problems, internalizing problems, and peer conflict functioning as mediators of these relations. PMID:26854507

  3. Risk Analysis of Earth-Rock Dam Failures Based on Fuzzy Event Tree Method

    PubMed Central

    Fu, Xiao; Gu, Chong-Shi; Su, Huai-Zhi; Qin, Xiang-Nan

    2018-01-01

    Earth-rock dams make up a large proportion of the dams in China, and their failures can induce great risks. In this paper, the risks associated with earth-rock dam failure are analyzed from two aspects: the probability of a dam failure and the resulting life loss. An event tree analysis method based on fuzzy set theory is proposed to calculate the dam failure probability. The life loss associated with dam failure is summarized and refined to be suitable for Chinese dams from previous studies. The proposed method and model are applied to one reservoir dam in Jiangxi province. Both engineering and non-engineering measures are proposed to reduce the risk. The risk analysis of the dam failure has essential significance for reducing dam failure probability and improving dam risk management level. PMID:29710824

  4. Growing Lemon Trees from Lemons: Lessons Reaped from a SoTL Faculty Learning Community's Research "Failures"

    ERIC Educational Resources Information Center

    Dich, Linh; Brown, Karen M.; Kuznekoff, Jeff H.; Conover, Theresa; Forren, John P.; Marshall, Janet

    2017-01-01

    Failure can be central to faculty research; however, failure produces a vehicle for learning. Through an interdisciplinary faculty community, the authors supported each other in facing, learning from, and overcoming "failed" aspects of research projects. This article reports obstacles encountered in conducting Scholarship of Teaching and…

  5. Relationships between Phytophthora ramorum canker (sudden oak death) and failure potential in coast live oak

    Treesearch

    Tedmund J. Swiecki; Elizabeth Bernhardt; Christiana Drake; Laurence R. Costello

    2006-01-01

    In autumn 2002, we conducted a retrospective study on coast live oak (Quercus agrifolia) failures in Marin County, California, woodlands affected by Phytophthora ramorum canker (sudden oak death). The objectives of this case-control study were to quantify levels of bole, large branch, and root failure in these woodlands and...

  6. An improved approach for flight readiness certification: Methodology for failure risk assessment and application examples. Volume 3: Structure and listing of programs

    NASA Technical Reports Server (NTRS)

    Moore, N. R.; Ebbeler, D. H.; Newlin, L. E.; Sutharshana, S.; Creager, M.

    1992-01-01

    An improved methodology for quantitatively evaluating failure risk of spaceflight systems to assess flight readiness and identify risk control measures is presented. This methodology, called Probabilistic Failure Assessment (PFA), combines operating experience from tests and flights with engineering analysis to estimate failure risk. The PFA methodology is of particular value when information on which to base an assessment of failure risk, including test experience and knowledge of parameters used in engineering analyses of failure phenomena, is expensive or difficult to acquire. The PFA methodology is a prescribed statistical structure in which engineering analysis models that characterize failure phenomena are used conjointly with uncertainties about analysis parameters and/or modeling accuracy to estimate failure probability distributions for specific failure modes. These distributions can then be modified, by means of statistical procedures of the PFA methodology, to reflect any test or flight experience. Conventional engineering analysis models currently employed for design of failure prediction are used in this methodology. The PFA methodology is described and examples of its application are presented. Conventional approaches to failure risk evaluation for spaceflight systems are discussed, and the rationale for the approach taken in the PFA methodology is presented. The statistical methods, engineering models, and computer software used in fatigue failure mode applications are thoroughly documented.

  7. SES, Heart Failure, and N-terminal Pro-b-type Natriuretic Peptide: The Atherosclerosis Risk in Communities Study.

    PubMed

    Vart, Priya; Matsushita, Kunihiro; Rawlings, Andreea M; Selvin, Elizabeth; Crews, Deidra C; Ndumele, Chiadi E; Ballantyne, Christie M; Heiss, Gerardo; Kucharska-Newton, Anna; Szklo, Moyses; Coresh, Josef

    2018-02-01

    Compared with coronary heart disease and stroke, the association between SES and the risk of heart failure is less well understood. In 12,646 participants of the Atherosclerosis Risk in Communities Study cohort free of heart failure history at baseline (1987-1989), the association of income, educational attainment, and area deprivation index with subsequent heart failure-related hospitalization or death was examined while accounting for cardiovascular disease risk factors and healthcare access. Because SES may affect threshold of identifying heart failure and admitting for heart failure management, secondarily the association between SES and N-terminal pro-b-type natriuretic peptide (NT-proBNP) levels, a marker reflecting cardiac overload, was investigated. Analysis was conducted in 2016. During a median follow-up of 24.3 years, a total of 2,249 participants developed heart failure. In a demographically adjusted model, the lowest-SES group had 2.2- to 2.5-fold higher risk of heart failure compared with the highest SES group for income, education, and area deprivation. With further adjustment for time-varying cardiovascular disease risk factors and healthcare access, these associations were attenuated but remained statistically significant (e.g., hazard ratio=1.92, 95% CI=1.69, 2.19 for the lowest versus highest income), with no racial interaction (p>0.05 for all SES measures). Similarly, compared with high SES, low SES was associated with both higher baseline level of NT-proBNP in a multivariable adjusted model (15% higher, p<0.001) and increase over time (~1% greater per year, p=0.023). SES was associated with clinical heart failure as well as NT-proBNP levels inversely and independently of traditional cardiovascular disease factors and healthcare access. Copyright © 2018 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.

  8. Sensor failure and multivariable control for airbreathing propulsion systems. Ph.D. Thesis - Dec. 1979 Final Report

    NASA Technical Reports Server (NTRS)

    Behbehani, K.

    1980-01-01

    A new sensor/actuator failure analysis technique for turbofan jet engines was developed. Three phases of failure analysis, namely detection, isolation, and accommodation are considered. Failure detection and isolation techniques are developed by utilizing the concept of Generalized Likelihood Ratio (GLR) tests. These techniques are applicable to both time varying and time invariant systems. Three GLR detectors are developed for: (1) hard-over sensor failure; (2) hard-over actuator failure; and (3) brief disturbances in the actuators. The probability distribution of the GLR detectors and the detectability of sensor/actuator failures are established. Failure type is determined by the maximum of the GLR detectors. Failure accommodation is accomplished by extending the Multivariable Nyquest Array (MNA) control design techniques to nonsquare system designs. The performance and effectiveness of the failure analysis technique are studied by applying the technique to a turbofan jet engine, namely the Quiet Clean Short Haul Experimental Engine (QCSEE). Single and multiple sensor/actuator failures in the QCSEE are simulated and analyzed and the effects of model degradation are studied.

  9. Meta-Analysis

    PubMed Central

    Kale-Pradhan, Pramodini B.; Mariani, Nicholas P.; Wilhelm, Sheila M.; Johnson, Leonard B.

    2015-01-01

    Background: Vancomycin is used to treat serious infections caused by methicillin-resistant Staphylococcus aureus (MRSA). It is unclear whether MRSA isolates with minimum inhibitory concentration (MIC) 1.5 to 2 µg/mL are successfully treated with vancomycin. Objective: Evaluate vancomycin failure rates in MRSA bacteremia with an MIC <1.5 versus ≥1.5 µg/mL, and MIC ≤1 versus ≥2 µg/mL. Methods: A literature search was conducted using MESH terms vancomycin, MRSA, bacteremia, MIC, treatment and vancomycin failure to identify human studies published in English. All studies of patients with MRSA bacteremia treated with vancomycin were included if they evaluated vancomycin failures, defined as mortality, and reported associated MICs determined by E-test. Study sample size, vancomycin failure rates, and corresponding MIC values were extracted and analyzed using RevMan 5.2.5. Results: Thirteen studies including 2955 patients met all criteria. Twelve studies including 2861 patients evaluated outcomes using an MIC cutoff of 1.5 µg/mL. A total of 413 of 1186 (34.8%) patients with an MIC <1.5 and 531 of 1675 (31.7%) patients with an MIC of ≥1.5 µg/mL experienced treatment failure (odds ratio = 0.72, 95% confidence interval = 0.49-1.04, P = .08). Six studies evaluated 728 patients using the cutoffs of ≤1 and ≥2 µg/mL. A total of 384 patients had isolates with MIC ≤1 µg/mL, 344 had an MIC ≥2 µg/mL. Therapeutic failure occurred in 87 and 102 patients, respectively (odds ratio = 0.61, 95% confidence interval = 0.34-1.10, P = .10). As heterogeneity between the studies was high, a random-effects model was used. Conclusion: Vancomycin MIC may not be an optimal sole indicator of vancomycin treatment failure in MRSA bacteremia.

  10. Application of Single Crystal Failure Criteria: Theory and Turbine Blade Case Study

    NASA Technical Reports Server (NTRS)

    Sayyah, Tarek; Swanson, Gregory R.; Schonberg, W. P.

    1999-01-01

    The orientation of the single crystal material within a structural component is known to affect the strength and life of the part. The first stage blade of the High Pressure Fuel Turbopump (HPFTP)/ Alternative Turbopump Development (ATD), of the Space Shuttle Main Engine (SSME) was used to study the effects of secondary axis'orientation angles on the failure rate of the blade. A new failure criterion was developed based on normal and shear strains on the primary crystallographic planes. The criterion was verified using low cycle fatigue (LCF) specimen data and a finite element model of the test specimens. The criterion was then used to study ATD/HPFTP first stage blade failure events. A detailed ANSYS finite element model of the blade was used to calculate the failure parameter for the different crystallographic orientations. A total of 297 cases were run to cover a wide range of acceptable orientations within the blade. Those orientations are related to the base crystallographic coordinate system that was created in the ANSYS finite element model. Contour plots of the criterion as a function of orientation for the blade tip and attachment were obtained. Results of the analysis revealed a 40% increase in the failure parameter due to changing of the primary and secondary axes of material orientations. A comparison between failure criterion predictions and actual engine test data was then conducted. The engine test data comes from two ATD/HPFTP builds (units F3- 4B and F6-5D), which were ground tested on the SSME at the Stennis Space Center in Mississippi. Both units experienced cracking of the airfoil tips in multiple blades, but only a few cracks grew all the way across the wall of the hollow core airfoil.

  11. Determination of slope failure using 2-D resistivity method

    NASA Astrophysics Data System (ADS)

    Muztaza, Nordiana Mohd; Saad, Rosli; Ismail, Nur Azwin; Bery, Andy Anderson

    2017-07-01

    Landslides and slope failure may give negative economic effects including the cost to repair structures, loss of property value and medical costs in the event of injury. To avoid landslide, slope failure and disturbance of the ecosystem, good and detailed planning must be done when developing hilly area. Slope failure classification and various factors contributing to the instability using 2-D resistivity survey conducted in Selangor, Malaysia are described. The study on landslide and slope failure was conducted at Site A and Site B, Selangor using 2-D resistivity method. The implications of the anticipated ground conditions as well as the field observation of the actual conditions are discussed. Nine 2-D resistivity survey lines were conducted in Site A and six 2-D resistivity survey lines with 5 m minimum electrode spacing using Pole-dipole array were performed in Site B. The data were processed using Res2Dinv and Surfer10 software to evaluate the subsurface characteristics. 2-D resistivity results from both locations show that the study areas consist of two main zones. The first zone is alluvium or highly weathered with the resistivity of 100-1000 Ωm at 20-70 m depth. This zone consists of saturated area (1-100 Ωm) and boulders with resistivity value of 1200-3000 Ωm. The second zone with resistivity values of > 3000 Ωm was interpreted as granitic bedrock. The study area was characterized by saturated zones, highly weathered zone, highly contain of sand and boulders that will trigger slope failure in the survey area. Based on the results obtained from the study findings, it can be concluded that 2-D resistivity method is useful method in determination of slope failure.

  12. Lipophilic versus hydrophilic statin therapy for heart failure: a protocol for an adjusted indirect comparison meta-analysis

    PubMed Central

    2013-01-01

    Background Statins are known to reduce cardiovascular morbidity and mortality in primary and secondary prevention studies. Subsequently, a number of nonrandomised studies have shown statins improve clinical outcomes in patients with heart failure (HF). Small randomised controlled trials (RCT) also show improved cardiac function, reduced inflammation and mortality with statins in HF. However, the findings of two large RCTs do not support the evidence provided by previous studies and suggest statins lack beneficial effects in HF. Two meta-analyses have shown statins do not improve survival, whereas two others showed improved cardiac function and reduced inflammation in HF. It appears lipophilic statins produce better survival and other outcome benefits compared to hydrophilic statins. But the two types have not been compared in direct comparison trials in HF. Methods/design We will conduct a systematic review and meta-analysis of lipophilic and hydrophilic statin therapy in patients with HF. Our objectives are: 1. To determine the effects of lipophilic statins on (1) mortality, (2) hospitalisation for worsening HF, (3) cardiac function and (4) inflammation. 2. To determine the effects of hydrophilic statins on (1) mortality, (2) hospitalisation for worsening HF, (3) cardiac function and (4) inflammation. 3. To compare the efficacy of lipophilic and hydrophilic statins on HF outcomes with an adjusted indirect comparison meta-analysis. We will conduct an electronic search of databases for RCTs that evaluate statins in patients with HF. The reference lists of all identified studies will be reviewed. Two independent reviewers will conduct the search. The inclusion criteria include: 1. RCTs comparing statins with placebo or no statin in patients with symptomatic HF. 2. RCTs that employed the intention-to-treat (ITT) principle in data analysis. 3. Symptomatic HF patients of all aetiologies and on standard treatment. 4. Statin of any dose as intervention. 5. Placebo or no statin arm as control. The exclusion criteria include: 1. RCTs involving cerivastatin in HF patients. 2. RCTs with less than 4 weeks of follow-up. Discussion We will perform an adjusted indirect comparison meta-analysis of lipophilic versus hydrophilic statins in patients with HF using placebo or no statin arm as common comparator. PMID:23618535

  13. Independent Orbiter Assessment (IOA): Analysis of the crew equipment subsystem

    NASA Technical Reports Server (NTRS)

    Sinclair, Susan; Graham, L.; Richard, Bill; Saxon, H.

    1987-01-01

    The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine failure modes, criticality, and potential critical (PCIs) items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The independent analysis results coresponding to the Orbiter crew equipment hardware are documented. The IOA analysis process utilized available crew equipment hardware drawings and schematics for defining hardware assemblies, components, and hardware items. Each level of hardware was evaluated and analyzed for possible failure modes and effects. Criticality was assigned based upon the severity of the effect for each failure mode. Of the 352 failure modes analyzed, 78 were determined to be PCIs.

  14. A comparative analysis of the results from 4 trials of beta-blocker therapy for heart failure: BEST, CIBIS-II, MERIT-HF, and COPERNICUS.

    PubMed

    Domanski, Michael J; Krause-Steinrauf, Heidi; Massie, Barry M; Deedwania, Prakash; Follmann, Dean; Kovar, David; Murray, David; Oren, Ron; Rosenberg, Yves; Young, James; Zile, Michael; Eichhorn, Eric

    2003-10-01

    Recent large randomized, controlled trials (BEST [Beta-blocker Evaluation of Survival Trial], CIBIS-II [Cardiac Insufficiency Bisoprolol Trial II], COPERNICUS [Carvedilol Prospective Randomized Cumulative Survival Study], and MERIT-HF [Metoprolol Randomized Intervention Trial in Congestive Heart Failure]) have addressed the usefulness of beta-blockade in the treatment of advanced heart failure. CIBIS-II, COPERNICUS, and MERIT-HF have shown that beta-blocker treatment with bisoprolol, carvedilol, and metoprolol XL, respectively, reduce mortality in advanced heart failure patients, whereas BEST found a statistically nonsignificant trend toward reduced mortality with bucindolol. We conducted a post hoc analysis to determine whether the response to beta-blockade in BEST could be related to differences in the clinical and demographic characteristics of the study populations. We generated a sample from BEST to resemble the patient cohorts studied in CIBIS-II and MERIT-HF to find out whether the response to beta-blocker therapy was similar to that reported in the other trials. These findings are further compared with COPERNICUS, which entered patients with more severe heart failure. To achieve conformity with the entry criteria for CIBIS-II and MERIT-HF, the BEST study population was adjusted to exclude patients with systolic blood pressure <100 mm Hg, heart rate <60 bpm, and age >80 years (exclusion criteria employed in those trials). The BEST comparison subgroup (BCG) was further modified to more closely reflect the racial demographics reported for patients enrolled in CIBIS-II and MERIT-HF. The association of beta-blocker therapy with overall survival and survival free of cardiac death, sudden cardiac death, and progressive pump failure in the BCG was assessed. In the BCG subgroup, bucindolol treatment was associated with significantly lower risk of death from all causes (hazard ratio (HR)=0.77 [95% CI=0.65, 0.92]), cardiovascular death (HR=0.71 [0.58, 0.86]), sudden death (HR=0.77 [0.59, 0.999]), and pump failure death (HR=0.64 [0.45, 0.91]). Although not excluding the possibility of differences resulting from chance alone or to different properties among beta-blockers, this study suggests the possibility that different heart failure population subgroups may have different responses to beta-blocker therapy.

  15. Can patients with moderate to severe acute respiratory failure from COPD be treated safely with noninvasive mechanical ventilation on the ward?

    PubMed

    Yalcinsoy, Murat; Salturk, Cuneyt; Oztas, Selahattin; Gungor, Sinem; Ozmen, Ipek; Kabadayi, Feyyaz; Oztim, Aysem Askim; Aksoy, Emine; Adıguzel, Nalan; Oruc, Ozlem; Karakurt, Zuhal

    2016-01-01

    Noninvasive mechanical ventilation (NIMV) usage outside of intensive care unit is not recommended in patients with COPD for severe acute respiratory failure (ARF). We assessed the factors associated with failure of NIMV in patients with ARF and severe acidosis admitted to the emergency department and followed on respiratory ward. This is a retrospective observational cohort study conducted in a tertiary teaching hospital specialized in chest diseases and thoracic surgery between June 1, 2013 and May 31, 2014. COPD patients who were admitted to our emergency department due to ARF were included. Patients were grouped according to the severity of acidosis into two groups: group 1 (pH=7.20-7.25) and group 2 (pH=7.26-7.30). Group 1 included 59 patients (mean age: 70±10 years, 30.5% female) and group 2 included 171 patients (mean age: 67±11 years, 28.7% female). On multivariable analysis, partial arterial oxygen pressure to the inspired fractionated oxygen (PaO2/FiO2) ratio <200, delta pH value <0.30, and pH value <7.31 on control arterial blood gas after NIMV in the emergency room and peak C-reactive protein were found to be the risk factors for NIMV failure in COPD patients with ARF in the ward. NIMV is effective not only in mild respiratory failure but also with severe forms of COPD patients presenting with severe exacerbation. The determination of the failure criteria of NIMV and the expertise of the team is critical for treatment success.

  16. Fluid overload and kidney failure in children with severe sepsis and septic shock: A cohort study.

    PubMed

    Naveda Romero, Omar E; Naveda Meléndez, Andrea F

    2017-04-01

    In children with sepsis, fluid overload as a result of an aggressive fluid replacement or excessive fluid administration may result in kidney impairment and increased mortality. Objective. To determine the association between fluid overload and the rate of kidney failure in a group of children with severe sepsis and septic shock. This was a prospective cohort study conducted in the intensive care unit of Hospital Universitario de Pediatría “Dr. Agustín Zubillaga” (Barquisimeto, Lara State, Venezuela), between March 2013 and May 2016, in children with severe sepsis or septic shock. One hundred and forty-nine patients were included in the analysis. Sepsis predominated in 59.7% of cases; patients' average age was 6.4 ± 3.3 years old, their average weight was 17.8 ± 3.6 kg, 30.2% had fluid overload, and overall mortality was 25.5%. Kidney failure occurred in 16.1% of cases. A binary logistic regression model was used to identify fluid overload (odds ratio [OR]: 1.5; 95% confidence interval [CI]: 1.2-4.9, p = 0.028) and shock for more than 2 days (OR: 1.7; 95% CI: 1.3-6.3, p = 0.039) as independent predictors of kidney failure. In addition, a significant increase in the risk of mortality among children with kidney failure and fluid overload was observed as per the Kaplan-Meier method (p= 0.019). Fluid overload and shock for more than 2 days increase the risk for kidney failure in critically ill children with severe sepsis and septic shock.

  17. TEAM-HF Cost-Effectiveness Model: A Web-Based Program Designed to Evaluate the Cost-Effectiveness of Disease Management Programs in Heart Failure

    PubMed Central

    Reed, Shelby D.; Neilson, Matthew P.; Gardner, Matthew; Li, Yanhong; Briggs, Andrew H.; Polsky, Daniel E.; Graham, Felicia L.; Bowers, Margaret T.; Paul, Sara C.; Granger, Bradi B.; Schulman, Kevin A.; Whellan, David J.; Riegel, Barbara; Levy, Wayne C.

    2015-01-01

    Background Heart failure disease management programs can influence medical resource use and quality-adjusted survival. Because projecting long-term costs and survival is challenging, a consistent and valid approach to extrapolating short-term outcomes would be valuable. Methods We developed the Tools for Economic Analysis of Patient Management Interventions in Heart Failure (TEAM-HF) Cost-Effectiveness Model, a Web-based simulation tool designed to integrate data on demographic, clinical, and laboratory characteristics, use of evidence-based medications, and costs to generate predicted outcomes. Survival projections are based on a modified Seattle Heart Failure Model (SHFM). Projections of resource use and quality of life are modeled using relationships with time-varying SHFM scores. The model can be used to evaluate parallel-group and single-cohort designs and hypothetical programs. Simulations consist of 10,000 pairs of virtual cohorts used to generate estimates of resource use, costs, survival, and incremental cost-effectiveness ratios from user inputs. Results The model demonstrated acceptable internal and external validity in replicating resource use, costs, and survival estimates from 3 clinical trials. Simulations to evaluate the cost-effectiveness of heart failure disease management programs across 3 scenarios demonstrate how the model can be used to design a program in which short-term improvements in functioning and use of evidence-based treatments are sufficient to demonstrate good long-term value to the health care system. Conclusion The TEAM-HF Cost-Effectiveness Model provides researchers and providers with a tool for conducting long-term cost-effectiveness analyses of disease management programs in heart failure. PMID:26542504

  18. The ethical issues in uranium mining research in the Navajo Nation.

    PubMed

    Panikkar, Bindu; Brugge, Doug

    2007-01-01

    We explore the experience of Navajo communities living under the shadow of nuclear age fallout who were subjects of five decades of research. In this historical analysis of public health (epidemiological) research conducted in the Navajo lands since the inception of uranium mining from the 1950s untill the end of the 20th century, we analyze the successes and failures in the research initiatives conducted on Navajo lands, the ethical breaches, and the harms and benefits that this research has brought about to the community. We discuss how scientific and moral uncertainty, lack of full stakeholder participation and community wide outreach and education can impact ethical decisions made in research.

  19. Laboratory and 3-D distinct element analysis of the failure mechanism of a slope under external surcharge

    NASA Astrophysics Data System (ADS)

    Li, N.; Cheng, Y. M.

    2015-01-01

    Landslide is a major disaster resulting in considerable loss of human lives and property damages in hilly terrain in Hong Kong, China and many other countries. The factor of safety and the critical slip surface for slope stabilization are the main considerations for slope stability analysis in the past, while the detailed post-failure conditions of the slopes have not been considered in sufficient detail. There is however increasing interest in the consequences after the initiation of failure that includes the development and propagation of the failure surfaces, the amount of failed mass and runoff and the affected region. To assess the development of slope failure in more detail and to consider the potential danger of slopes after failure has initiated, the slope stability problem under external surcharge is analyzed by the distinct element method (DEM) and a laboratory model test in the present research. A more refined study about the development of failure, microcosmic failure mechanisms and the post-failure mechanisms of slopes will be carried out. The numerical modeling method and the various findings from the present work can provide an alternate method of analysis of slope failure, which can give additional information not available from the classical methods of analysis.

  20. Laboratory and 3-D-distinct element analysis of failure mechanism of slope under external surcharge

    NASA Astrophysics Data System (ADS)

    Li, N.; Cheng, Y. M.

    2014-09-01

    Landslide is a major disaster resulting in considerable loss of human lives and property damages in hilly terrain in Hong Kong, China and many other countries. The factor of safety and the critical slip surface for slope stabilization are the main considerations for slope stability analysis in the past, while the detailed post-failure conditions of the slopes have not been considered in sufficient details. There are however increasing interest on the consequences after the initiation of failure which includes the development and propagation of the failure surfaces, the amount of failed mass and runoff and the affected region. To assess the development of slope failure in more details and to consider the potential danger of slopes after failure has initiated, the slope stability problem under external surcharge is analyzed by the distinct element method (DEM) and laboratory model test in the present research. A more refined study about the development of failure, microcosmic failure mechanism and the post-failure mechanism of slope will be carried out. The numerical modeling method and the various findings from the present work can provide an alternate method of analysis of slope failure which can give additional information not available from the classical methods of analysis.

  1. Failure Analysis and Recovery of a 50 MM Highly Elastic Intermetallic NiTi Ball Bearing for an ISS Application

    NASA Technical Reports Server (NTRS)

    DellaCorte, Christopher; Howard, S. Adam; Moore, Lewis E., III

    2016-01-01

    The ISS Distillation Assembly centrifuge is the pathfinder application for 50mm bore, deep-groove ball bearings made from the highly elastic intermetallic material 60NiTi. Superior corrosion and shock resistance are required to withstand the acidic wastewater exposure and heavy spacecraft launch related loads that challenge conventional steel bearings. During early ground testing one bearing unexpectedly and catastrophically failed after operating for only 200 hours of run time. A second bearing running on the same shaft was completely unaffected. A thorough investigation into the root cause of the failure determined that an excessively tight press-fit of the bearing outer race coupled with NiTis relatively low elastic modulus were key contributing factors. The proposed failure mode was successfully duplicated by experiment. To further corroborate the root cause theory, a successful bearing life test using improved installation practices (selective fitting) was conducted. The results show that NiTi bearings are suitable for space applications provided that care is taken to accommodate their unique material characteristics.

  2. Progressive failure of lower San Fernando dam

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gu, W.H.; Morgenstern, N.R.; Robertson, P.K.

    1993-02-01

    Postearthquake deformation analyses of the lower San Fernando dam were conducted using an incremental finite-element method. In the analyses, an undrained elastoplastic model was used to simulate the collapse of liquefied materials. The model is developed based on the critical-state boundary-surface theory, the concept of steady-state strength, and the undrained behavior of liquefiable soils. A triggering condition in terms of a collapse surface was considered in this model. The hyperbolic strain-softening relationship has been introduced to simulate the postpeak behavior of liquefied materials. The analyses have shown that a progressive failure under undrained conditions may explain the observed response ofmore » the lower San Fernando dam following the 1971 earthquake. Stress redistribution initiated by the strain softening of liquefied materials is the main reason for undrained flow failures of dams, slopes, and foundations and can occur in a short period ranging from a few seconds to a few minutes. The liquefied zone after stress redistribution may be much larger than the initial liquefied zone caused directly by an earthquake. Therefore, a postearthquake deformation analysis may be essential in liquefaction stability evaluations.« less

  3. Failure Analysis and Recovery of a 50mm Highly Elastic Intermetallic NiTi Ball Bearing for an ISS Application

    NASA Technical Reports Server (NTRS)

    DellaCorte, Christopher; Howard, S. Adam; Moore, Lewis E., III

    2016-01-01

    The ISS Distillation Assembly centrifuge is the pathfinder application for 50mm bore, deep-groove ball bearings made from the highly elastic intermetallic material 60NiTi. Superior corrosion and shock resistance are required to withstand the acidic wastewater exposure and heavy spacecraft launch related loads that challenge conventional steel bearings. During early ground testing one bearing unexpectedly and catastrophically failed after operating for only 200 hours of run time. A second bearing running on the same shaft was completely unaffected. A thorough investigation into the root cause of the failure determined that an excessively tight press-fit of the bearing outer race coupled with NiTis relatively low elastic modulus were key contributing factors. The proposed failure mode was successfully duplicated by experiment. To further corroborate the root cause theory, a successful bearing life test using improved installation practices (selective fitting) was conducted. The results show that NiTi bearings are suitable for space applications provided that care is taken to accommodate their unique material characteristics.

  4. Stable tearing behavior of a thin-sheet material with multiple cracks

    NASA Technical Reports Server (NTRS)

    Dawicke, D. S.; Newman, J. C., Jr.; Sutton, M. A.; Amstutz, B. E.

    1994-01-01

    Fracture tests were conducted on 2.3mm thick, 305mm wide sheets of 2024-T3 aluminum alloy with 1-5 collinear cracks. The cracks were introduced (crack history) into the specimens by three methods: (1) saw cutting; (2) fatigue precracking at a low stress range; and (3) fatigue precracking at a high stress range. For the single crack tests, the initial crack history influenced the stress required for the onset of stable crack growth and the first 10mm of crack growth. The effect on failure stress was about 4 percent or less. For the multiple crack tests, the initial crack history was shown to cause differences of more than 20 percent in the link-up stress and 13 percent in failure stress. An elastic-plastic finite element analysis employing the Crack Tip Opening Angle (CTOA) fracture criterion was used to predict the fracture behavior of the single and multiple crack tests. The numerical predictions were within 7 percent of the observed link-up and failure stress in all the tests.

  5. Influence of crack history on the stable tearing behavior of a thin-sheet material with multiple cracks

    NASA Technical Reports Server (NTRS)

    Dawicke, D. S.; Newman, J. C., Jr.; Sutton, M. A.; Amstutz, B. E.

    1994-01-01

    Fracture tests were conducted on 2.3mm thick, 305mm wide sheets of 2024-T3 aluminum alloy with from one to five collinear cracks. The cracks were introduced (crack history) into the specimens by three methods: saw cutting, fatigue precracking at a low stress range, and fatigue precracking at a high stress range. For the single crack tests, the initial crack history influenced the stress required for the onset of stable crack growth and the first 10mm of crack growth. The effect on failure stress was about 4 percent or less. For the multiple crack tests, the initial crack history was shown to cause differences of more than 20 percent in the link-up stress and 13 percent in failure stress. An elastic-plastic finite element analysis employing the CTOA fracture criterion was used to predict the fracture behavior of the single and multiple crack tests. The numerical predictions were within 7 percent of the observed link-up and failure stress in all the tests.

  6. Failure Analysis and Recovery of a 50-mm Highly Elastic Intermetallic NiTi Ball Bearing for an ISS Application

    NASA Technical Reports Server (NTRS)

    DellaCorte, Christopher; Howard, S. Adam; Moore, Lewis

    2016-01-01

    Ball bearings used inside the ISS Distillation Assembly centrifuge require superior corrosion and shock resistance to withstand acidic wastewater exposure and heavy spacecraft launch related loads. These requirements challenge conventional steel bearings and provide an ideal pathfinder application for 50-mm bore, deep-groove ball bearings made from the corrosion immune and highly elastic intermetallic material 60NiTi. During early ground testing in 2014 one 60NiTi bearing unexpectedly and catastrophically failed after operating for only 200 hr. A second bearing running on the same shaft was completely unaffected. An investigation into the root cause of the failure determined that an excessively tight press fit of the bearing outer race coupled with NiTi's relatively low elastic modulus were key contributing factors. The proposed failure mode was successfully replicated by experiment. To further corroborate the root cause theory, a successful bearing life test using improved installation practices (selective fitting) was conducted. The results show that NiTi bearings are suitable for space applications provided that care is taken to accommodate their unique material characteristics.

  7. Clinical characteristics of ceftriaxone plus metronidazole in complicated intra-abdominal infection

    PubMed Central

    2015-01-01

    Purpose Empirical antibiotics in complicated intra-abdominal infection (c-IAI), such as secondary peritonitis are a first step of treatment. Empirical antibiotic regimen is very diverse. Ceftriaxone plus metronidazole regimen (CMR) is one of the empirical antibiotic regimens used in treatment of c-IAI. However, although CMR is a widely used empirical antibiotic regimen, study regarding success, failure or efficacy of CMR has been poorly understood. This retrospective study is conducted to compare the clinical efficacy of this regimen in c-IAI according to clinical characteristics. Methods The subjects were patients in this hospital who were diagnosed as secondary peritonitis between 2009 and 2013. Retrospective analysis was performed based on the records made after surgery regarding clinical characteristics including albumin level, blood pressure, pulse rate, respiration rate, smoking, age, sex, body mass index, hemoglobin, coexisting disease, leukocytosis, and APACHE (acute physiology and chronic health evaluation) II score. Results A total of 114 patients were enrolled. In univariated analysis, the success and failure of CMR showed significant association with preoperative low albumin, old age, and preoperative tachycardia. In multivariated analysis, low albumin and preoperative tachycardia were significant. Conclusion It is thought that an additional antibiotic treatment plan is necessary in patients with low albumin and tachycardia when the empirical antibiotic regimen is CMR in c-IAI. Conduct of research through well-designed prospective randomized clinical study is also necessary in order to evaluate the appropriateness of CMR and decide on a proper empirical antibiotic regimen between many regimens in c-IAI based on our country. PMID:26131444

  8. Electromigration analysis of solder joints under ac load: A mean time to failure model

    NASA Astrophysics Data System (ADS)

    Yao, Wei; Basaran, Cemal

    2012-03-01

    In this study, alternating current (ac) electromigration (EM) degradation simulations were carried out for Sn95.5%Ag4.0%Cu0.5 (SAC405- by weight) solder joints. Mass transport analysis was conducted with viscoplastic material properties for quantifying damage mechanism in solder joints. Square, sine, and triangle current wave forms ac were used as input signals. dc and pulsed dc (PDC) electromigration analysis were conducted for comparison purposes. The maximum current density ranged from 2.2×106A/cm2 to 5.0×106A/cm2, frequency ranged from 0.05 Hz to 5 Hz with ambient temperature varying from 350 K to 450 K. Because the room temperature is nearly two-thirds of SAC solder joint's melting point on absolute temperature scale (494.15 K), viscoplastic material model is essential. Entropy based damage evolution model was used to investigate mean time to failure (MTF) behavior of solder joints subjected to ac stressing. It was observed that MTF was inversely proportional to ambient temperature T1.1 in Celsius and also inversely proportional to current density j0.27 in A/cm2. Higher frequency will lead to a shorter lifetime with in the frequency range we studied, and a relationship is proposed as MTF∝f-0.41. Lifetime of a solder joint subjected to ac is longer compared with dc and PDC loading conditions. By introducing frequency, ambient temperature and current density dependency terms, a modified MTTF equation was proposed for solder joints subjected to ac current stressing.

  9. Rapid evolution of asymmetric reproductive incompatibilities in stalk-eyed flies.

    PubMed

    Rose, Emily G; Brand, Cara L; Wilkinson, Gerald S

    2014-02-01

    The steps by which isolated populations acquire reproductive incompatibilities remain poorly understood. One potentially important process is postcopulatory sexual selection because it can generate divergence between populations in traits that influence fertilization success after copulation. Here we present a comprehensive analysis of this form of reproductive isolation by conducting reciprocal crosses between variably diverged populations of stalk-eyed flies (Teleopsis dalmanni). First, we measure seven types of reproductive incompatibility between copulation and fertilization. We then compare fertilization success to hatching success to quantify hybrid inviability. Finally, we determine if sperm competition acts to reinforce or counteract any incompatibilities. We find evidence for multiple incompatibilities in most crosses, including failure to store sperm after mating, failure of sperm to reach the site of fertilization, failure of sperm to fertilize eggs, and failure of embryos to develop. Local sperm have precedence over foreign sperm, but this effect is due mainly to differences in sperm transfer and reduced hatching success. Crosses between recently diverged populations are asymmetrical with regard to the degree and type of incompatibility. Because sexual conflict in these flies is low, postcopulatory sexual selection, rather than antagonistic coevolution, likely causes incompatibilities due to mismatches between male and female reproductive traits. © 2013 The Author(s). Evolution © 2013 The Society for the Study of Evolution.

  10. Treatment outcomes in patients with third-generation cephalosporin-resistant Enterobacter bacteremia.

    PubMed

    O'Neal, Catherine S; O'Neal, Hollis R; Daniels, Titus L; Talbot, Thomas R

    2012-10-01

    Infections with resistant Enterobacter spp. are increasingly described, yet data on outcomes associated with these infections are limited. A retrospective cohort study was conducted to investigate outcomes of hospitalized patients with third-generation cephalosporin-resistant (CR) Enterobacter bacteremia. Cephalosporin resistance was detected using cefotaxime and cefpodoxime. Patients with Enterobacter spp. bacteremia from January 2006 through February 2008 defined the population. We defined cases as those with CR isolates; controls were patients with bacteremia due to non-CR isolates. Treatment failure was defined as persistence of the presenting signs of infection 72 h after initial culture collection. Of the 95 Enterobacter cases identified, 31 (33%) were CR. CR cases were significantly associated with treatment failure (odds ratio (OR) 2.81, 95% confidence interval (CI) 1.14-6.94). This association was not seen after adjustment for age, simplified acute physiology score (SAPS II), and inappropriate empiric antibiotic therapy. Inappropriate empiric therapy (adjusted OR 3.86, 95% CI 1.32-11.31) and SAPS II score (adjusted OR 1.09, 95% CI 1.02-1.16) were significantly associated with treatment failure in the multivariate analysis. Third-generation cephalosporin-resistant Enterobacter bacteremia is associated with treatment failure due to receipt of inappropriate empiric antibiotic therapy and severity of illness.

  11. Palliative care consultations for heart failure patients: how many, when, and why?

    PubMed

    Bakitas, Marie; Macmartin, Meredith; Trzepkowski, Kenneth; Robert, Alina; Jackson, Lisa; Brown, Jeremiah R; Dionne-Odom, James N; Kono, Alan

    2013-03-01

    In preparation for development of a palliative care intervention for patients with heart failure (HF) and their caregivers, we aimed to characterize the HF population receiving palliative care consultations (PCCs). Reviewing charts from January 2006 to April 2011, we analyzed HF patient data including demographic and clinical characteristics, Seattle Heart Failure scores, and PCCs. Using Atlas qualitative software, we conducted a content analysis of PCC notes to characterize palliative care assessment and treatment recommendations. There were 132 HF patients with PCCs, of which 37% were New York Heart Association functional class III and 50% functional class IV. Retrospectively computed Seattle Heart Failure scores predicted 1-year mortality of 29% [interquartile range (IQR) 19-45] and median life expectancy of 2.8 years [IQR 1.6-4.2] years. Of the 132 HF patients, 115 (87%) had died by the time of the audit. In that cohort the actual median time from PCC to death was 21 [IQR 3-125] days. Reasons documented for PCCs included goals of care (80%), decision making (24%), hospice referral/discussion (24%), and symptom management (8%). Despite recommendations, PCCs are not being initiated until the last month of life. Earlier referral for PCC may allow for integration of a broader array of palliative care services. Copyright © 2013 Elsevier Inc. All rights reserved.

  12. Morphological and ultrastructural evaluation of the golden retriever muscular dystrophy trachea, lungs, and diaphragm muscle.

    PubMed

    Lessa, Thais Borges; de Abreu, Dilayla Kelly; Rodrigues, Márcio Nogueira; Brólio, Marina Pandolphi; Miglino, Maria Angélica; Ambrósio, Carlos Eduardo

    2014-11-01

    Duchenne muscular dystrophy (DMD) is a genetic disease, characterized by atrophy and muscle weakness. The respiratory failure is a common cause of early death in patients with DMD. Golden retriever muscular dystrophy (GRMD) is a canine model which has been extensively used for many advances in therapeutics applications. As the patients with DMD, the GRMD frequently died from cardiac and respiratory failure. Observing the respiratory failure in DMD is one of the major causes of mortality we aimed to describe the morphological and ultrastructural data of trachea, lungs (conductive and respiratory portion of the system), and diaphragm muscle using histological and ultrastructural analysis. The diaphragm muscle showed discontinuous fibers architecture, with different diameter; a robust perimysium inflammatory infiltrate and some muscle cells displayed central nuclei. GRMD trachea and lungs presented collagen fibers and in addition, the GRMD lungs showed higher of levels collagen fibers that could limit the alveolar ducts and alveoli distension. Therefore, the most features observed were the collagen areas and fibrosis. We suggested in this study that the collagen remodeling in the trachea, lungs, and diaphragm muscle may increase fibrosis and affect the trachea, lungs, and diaphragm muscle function that can be a major cause of respiratory failure that occur in patients with DMD. © 2014 Wiley Periodicals, Inc.

  13. Growth and nutritional status of children with homozygous sickle cell disease.

    PubMed

    Al-Saqladi, A-W M; Cipolotti, R; Fijnvandraat, K; Brabin, B J

    2008-09-01

    Poor growth and under-nutrition are common in children with sickle cell disease (SCD). This review summarises evidence of nutritional status in children with SCD in relation to anthropometric status, disease severity, body composition, energy metabolism, micronutrient deficiency and endocrine dysfunction. A literature search was conducted on the Medline/PUBMED, SCOPUS, SciELO and LILACS databases to July 2007 using the keywords sickle cell combined with nutrition, anthropometry, growth, height and weight, body mass index, and specific named micronutrients. Forty-six studies (26 cross-sectional and 20 longitudinal) were included in the final anthropometric analysis. Fourteen of the longitudinal studies were conducted in North America, the Caribbean or Europe, representing 78.8% (2086/2645) of patients. Most studies were observational with wide variations in sample size and selection of reference growth data, which limited comparability. There was a paucity of studies from Africa and the Arabian Peninsula, highlighting a large knowledge gap for low-resource settings. There was a consistent pattern of growth failure among affected children from all geographic areas, with good evidence linking growth failure to endocrine dysfunction, metabolic derangement and specific nutrient deficiencies. The monitoring of growth and nutritional status in children with SCD is an essential requirement for comprehensive care, facilitating early diagnosis of growth failure and nutritional intervention. Randomised controlled trials are necessary to assess the potential benefits of nutritional interventions in relation to growth, nutritional status and the pathophysiology of the disease.

  14. Metallurgical failure analysis of MH-1A reactor core hold-down bolts. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hawthorne, J.R.; Watson, H.E.

    1976-11-01

    The Naval Research Laboratory has performed a failure analysis on two MH-1A reactor core hold-down bolts that broke in service. Adherence to fabrication specifications, post-service properties and possible causes of bolt failure were investigated. The bolt material was verified as 17-4PH precipitation hardening stainless steel. Measured bolt dimensions also were in accordance with fabrication drawing specifications. Bolt failure occurred in the region of a locking pin hole which reduced the bolt net section by 47 percent. The failure analysis indicates that the probable cause of failure was net section overloading resulting from a lateral bending force on the bolt. Themore » analysis indicates that net section overloading could also have resulted from combined tensile stresses (bolt preloading plus differential thermal expansion). Recommendations are made for improved bolting.« less

  15. Ballistic Impact Testing of Aluminum 2024 and Titanium 6Al-4V for Material Model Development

    NASA Technical Reports Server (NTRS)

    Pereira, J. Michael; Revilock, Duane M.; Ruggeri, Charles R.; Emmerling, William C.; Altobelli, Donald J.

    2012-01-01

    An experimental program is underway to develop a consistent set of material property and impact test data, and failure analysis, for a variety of materials that can be used to develop improved impact failure and deformation models. Unique features of this set of data are that all material property information and impact test results are obtained using identical materials, the test methods and procedures are extensively documented and all of the raw data is available. This report describes ballistic impact testing which has been conducted on aluminum (Al) 2024 and titanium (Ti) 6Al-4vanadium (V) sheet and plate samples of different thicknesses and with different types of projectiles, one a regular cylinder and one with a more complex geometry incorporating features representative of a jet engine fan blade.

  16. Mixed-mode cyclic debonding of adhesively bonded composite joints. M.S. Thesis

    NASA Technical Reports Server (NTRS)

    Rezaizadeh, M. A.; Mall, S.

    1985-01-01

    A combined experimental-analytical investigation to characterize the cyclic failure mechanism of a simple composite-to-composite bonded joint is conducted. The cracked lap shear (CLS) specimens of graphite/epoxy adherend bonded with EC-3445 adhesive are tested under combined mode 1 and 2 loading. In all specimens tested, fatigue failure occurs in the form of cyclic debonding. The cyclic debond growth rates are measured. The finite element analysis is employed to compute the mode 1, mode 2, and total strain energy release rates (i.e., GI, GII, and GT). A wide range of mixed-mode loading, i.e., GI/GII ranging from 0.03 to 0.38, is obtained. The total strain energy release rate, G sub T, appeared to be the driving parameter for cyclic debonding in the tested composite bonded system.

  17. Mechanical Properties and Tensile Failure Analysis of Novel Bio-absorbable Mg-Zn-Cu and Mg-Zn-Se Alloys for Endovascular Applications

    PubMed Central

    Persaud-Sharma, Dharam; Budiansky, Noah; McGoron, Anthony J.

    2013-01-01

    In this paper, the mechanical properties and tensile failure mechanism of two novel bio-absorbable as-cast Mg-Zn-Se and Mg-Zn-Cu alloys for endovascular medical applications are characterized. Alloys were manufactured using an ARC melting process and tested as-cast with compositions of Mg-Zn-Se and Mg-Zn-Cu, being 98/1/1 wt.% respectively. Nanoindentation testing conducted at room temperature was used to characterize the elastic modulus (E) and surface hardness (H) for both the bare alloys and the air formed oxide layer. As compared to currently available shape memory alloys and degradable as-cast alloys, these experimental alloys possess superior as-cast mechanical properties that can increase their biocompatibility, degradation kinetics, and the potential for medical device creation. PMID:23543822

  18. Failure Analysis of CCD Image Sensors Using SQUID and GMR Magnetic Current Imaging

    NASA Technical Reports Server (NTRS)

    Felt, Frederick S.

    2005-01-01

    During electrical testing of a Full Field CCD Image Senor, electrical shorts were detected on three of six devices. These failures occurred after the parts were soldered to the PCB. Failure analysis was performed to determine the cause and locations of these failures on the devices. After removing the fiber optic faceplate, optical inspection was performed on the CCDs to understand the design and package layout. Optical inspection revealed that the device had a light shield ringing the CCD array. This structure complicated the failure analysis. Alternate methods of analysis were considered, including liquid crystal, light and thermal emission, LT/A, TT/A SQUID, and MP. Of these, SQUID and MP techniques were pursued for further analysis. Also magnetoresistive current imaging technology is discussed and compared to SQUID.

  19. Stingray Failure Mode, Effects and Criticality Analysis: WEC Risk Registers

    DOE Data Explorer

    Ken Rhinefrank

    2016-07-25

    Analysis method to systematically identify all potential failure modes and their effects on the Stingray WEC system. This analysis is incorporated early in the development cycle such that the mitigation of the identified failure modes can be achieved cost effectively and efficiently. The FMECA can begin once there is enough detail to functions and failure modes of a given system, and its interfaces with other systems. The FMECA occurs coincidently with the design process and is an iterative process which allows for design changes to overcome deficiencies in the analysis.Risk Registers for major subsystems completed according to the methodology described in "Failure Mode Effects and Criticality Analysis Risk Reduction Program Plan.pdf" document below, in compliance with the DOE Risk Management Framework developed by NREL.

  20. Contemporary Impact Analysis Methodology for Planetary Sample Return Missions

    NASA Technical Reports Server (NTRS)

    Perino, Scott V.; Bayandor, Javid; Samareh, Jamshid A.; Armand, Sasan C.

    2015-01-01

    Development of an Earth entry vehicle and the methodology created to evaluate the vehicle's impact landing response when returning to Earth is reported. NASA's future Mars Sample Return Mission requires a robust vehicle to return Martian samples back to Earth for analysis. The Earth entry vehicle is a proposed solution to this Mars mission requirement. During Earth reentry, the vehicle slows within the atmosphere and then impacts the ground at its terminal velocity. To protect the Martian samples, a spherical energy absorber called an impact sphere is under development. The impact sphere is composed of hybrid composite and crushable foam elements that endure large plastic deformations during impact and cause a highly nonlinear vehicle response. The developed analysis methodology captures a range of complex structural interactions and much of the failure physics that occurs during impact. Numerical models were created and benchmarked against experimental tests conducted at NASA Langley Research Center. The postimpact structural damage assessment showed close correlation between simulation predictions and experimental results. Acceleration, velocity, displacement, damage modes, and failure mechanisms were all effectively captured. These investigations demonstrate that the Earth entry vehicle has great potential in facilitating future sample return missions.

  1. Investigating premature pavement failure due to moisture : final report : appendices.

    DOT National Transportation Integrated Search

    2009-07-01

    The article are appendices. : This report details the forensic investigations conducted to identify the causes of pavement failures shortly after a rehabilitation activity on five interstate highway projects in Oregon, and the research efforts conduc...

  2. In-Flight Validation of a Pilot Rating Scale for Evaluating Failure Transients in Electronic Flight Control Systems

    NASA Technical Reports Server (NTRS)

    Kalinowski, Kevin F.; Tucker, George E.; Moralez, Ernesto, III

    2006-01-01

    Engineering development and qualification of a Research Flight Control System (RFCS) for the Rotorcraft Aircrew Systems Concepts Airborne Laboratory (RASCAL) JUH-60A has motivated the development of a pilot rating scale for evaluating failure transients in fly-by-wire flight control systems. The RASCAL RFCS includes a highly-reliable, dual-channel Servo Control Unit (SCU) to command and monitor the performance of the fly-by-wire actuators and protect against the effects of erroneous commands from the flexible, but single-thread Flight Control Computer. During the design phase of the RFCS, two piloted simulations were conducted on the Ames Research Center Vertical Motion Simulator (VMS) to help define the required performance characteristics of the safety monitoring algorithms in the SCU. Simulated failures, including hard-over and slow-over commands, were injected into the command path, and the aircraft response and safety monitor performance were evaluated. A subjective Failure/Recovery Rating (F/RR) scale was developed as a means of quantifying the effects of the injected failures on the aircraft state and the degree of pilot effort required to safely recover the aircraft. A brief evaluation of the rating scale was also conducted on the Army/NASA CH-47B variable stability helicopter to confirm that the rating scale was likely to be equally applicable to in-flight evaluations. Following the initial research flight qualification of the RFCS in 2002, a flight test effort was begun to validate the performance of the safety monitors and to validate their design for the safe conduct of research flight testing. Simulated failures were injected into the SCU, and the F/RR scale was applied to assess the results. The results validate the performance of the monitors, and indicate that the Failure/Recovery Rating scale is a very useful tool for evaluating failure transients in fly-by-wire flight control systems.

  3. Failure Waves in Cylindrical Glass Bars

    NASA Astrophysics Data System (ADS)

    Cazamias, James U.; Bless, Stephan J.; Marder, Michael P.

    1997-07-01

    Failure waves, a propagating front separating virgin and comminuted material, have been receiving a fair amount of attention the last couple of years. While most scientists have been looking at failure waves in plate impact geometries, we have conducted a series of experiments on Pyrex bars. In this paper, we present two types of photographic data from a series of tests. A streak camera was used to determine velocities of the failure front as a function of impact stress. A polaroid camera and a flash lamp provide detailed pictures of the actual event. Attempts were made to observe failure waves in amorphous quartz and acrylic.

  4. Failure warning of hydrous sandstone based on electroencephalogram technique

    NASA Astrophysics Data System (ADS)

    Tao, Kai; Zheng, Wei

    2018-06-01

    Sandstone is a type of rock mass that widely exists in nature. Moisture is an important factor that leads to sandstone structural failure. The major failure assessment methods of hydrous sandstone at present cannot satisfy real-time and portability requirements, especially lacks of warning function. In this study, acoustic emission (AE) and computed tomography (CT) techniques are combined for real-time failure assessment of hydrous sandstone. Eight visual colors for warning are screened according to different failure states, and an electroencephalogram (EEG) experiment is conducted to demonstrate their diverse excitations of the human brain's concentration.

  5. How to apply clinical cases and medical literature in the framework of a modified "failure mode and effects analysis" as a clinical reasoning tool--an illustration using the human biliary system.

    PubMed

    Wong, Kam Cheong

    2016-04-06

    Clinicians use various clinical reasoning tools such as Ishikawa diagram to enhance their clinical experience and reasoning skills. Failure mode and effects analysis, which is an engineering methodology in origin, can be modified and applied to provide inputs into an Ishikawa diagram. The human biliary system is used to illustrate a modified failure mode and effects analysis. The anatomical and physiological processes of the biliary system are reviewed. Failure is defined as an abnormality caused by infective, inflammatory, obstructive, malignancy, autoimmune and other pathological processes. The potential failures, their effect(s), main clinical features, and investigation that can help a clinician to diagnose at each anatomical part and physiological process are reviewed and documented in a modified failure mode and effects analysis table. Relevant medical and surgical cases are retrieved from the medical literature and weaved into the table. A total of 80 clinical cases which are relevant to the modified failure mode and effects analysis for the human biliary system have been reviewed and weaved into a designated table. The table is the backbone and framework for further expansion. Reviewing and updating the table is an iterative and continual process. The relevant clinical features in the modified failure mode and effects analysis are then extracted and included in the relevant Ishikawa diagram. This article illustrates an application of engineering methodology in medicine, and it sows the seeds of potential cross-pollination between engineering and medicine. Establishing a modified failure mode and effects analysis can be a teamwork project or self-directed learning process, or a mix of both. Modified failure mode and effects analysis can be deployed to obtain inputs for an Ishikawa diagram which in turn can be used to enhance clinical experiences and clinical reasoning skills for clinicians, medical educators, and students.

  6. Analysis of the effects of firing Orbiter primary reaction control system jets with an attached truss structure

    NASA Technical Reports Server (NTRS)

    Kaszubowski, M.; Raney, J. P.

    1986-01-01

    A study was conducted to determine the dynamic effects of firing the orbiter primary reaction control jets during assembly of protoflight space station structure. Maximum longeron compressive load was calculated as a function of jet pulse time length, number of jet pulses, and total torque imposed by the reaction control jets. The study shows that it is possible to fire selected jets to achieve a pitch maneuver without causing failure of the attached structure.

  7. Preparation Torque Limit for Composites Joined with Mechanical Fasteners

    NASA Technical Reports Server (NTRS)

    Thomas, Frank P.; Yi, Zhao

    2005-01-01

    Current design guidelines for determining torque ranges for composites are based on tests and analysis from isotropic materials. Properties of composites are not taken into account. No design criteria based upon a systematic analytical and test analyses is available. This paper is to study the maximum torque load a composite component could carry prior to any failure. Specifically, the torque-tension tests are conducted. NDT techniques including acoustic emission, thermography and photomicroscopy are also utilized to characterize the damage modes.

  8. The development of control and monitoring system on marine current renewable energy Case study: strait of Toyapakeh - Nusa Penida, Bali

    NASA Astrophysics Data System (ADS)

    Arief, I. S.; Suherman, I. H.; Wardani, A. Y.; Baidowi, A.

    2017-05-01

    Control and monitoring system is a continuous process of securing the asset in the Marine Current Renewable Energy. A control and monitoring system is existed each critical components which is embedded in Failure Mode Effect Analysis (FMEA) method. As the result, the process in this paper developed through a matrix sensor. The matrix correlated to critical components and monitoring system which supported by sensors to conduct decision-making.

  9. Reliability and Maintainability Analysis of Fluidic Back-Up Flight Control System and Components.

    DTIC Science & Technology

    1981-09-01

    industry. 2 r ~~m~ NADC 80227- 60 Maintainability Review of FMEA worksheets indicates that the standard hydraulic components of the servoactuator will...achieved. Procedures for conducting the FMEA and evaluating the 6 & | I NADC 80227- 60 severity of each failure mode are included as Appendix A...KEYSER N62269-81-M-3047 UNCLASSIFIED NADC-80227- 60 NL 66 11111.5 .4 11 6 MICROCOPY RESOLUTION TEST CHART N~ATIONAL BUR[AU Of STANDARDS 1%3A, REPORT

  10. miRNAs as biomarkers for diagnosis of heart failure

    PubMed Central

    Yan, Hualin; Ma, Fan; Zhang, Yi; Wang, Chuan; Qiu, Dajian; Zhou, Kaiyu; Hua, Yimin; Li, Yifei

    2017-01-01

    Abstract Background: With the rapid development of molecular biology, the kind of mircoRNA (miRNA) has been introduced into emerging role both in cardiac development and pathological procedure. Thus, we conduct this meta-analysis to find out the role of circulating miRNA as a biomarker in detecting heart failure. Methods: We searched PubMed, EMBASE, the Cochrane Central Register of Controlled Trials, and World Health Organization clinical trials registry center to identify relevant studies up to August 2016. We performed meta-analysis in a fixed/random-effect model using Meta-disc 1.4. We used STATA 14.0 to estimate the publication bias and meta-regression. Besides, we took use of SPSS 17.0 to evaluate variance between several groups. Information on true positive, false positive, false negative, and true negative, as well as the quality of research was extracted. Results: We use results from 10 articles to analyze the pooled accuracy. The overall performance of total mixed miRNAs (TmiRs) detection was: pooled sensitivity, 0.74 (95% confidence interval [CI], 0.72 to 0.75); pooled specificity, 0.69 (95%CI, 0.67 to 0.71); and area under the summary receiver operating characteristic curves value (SROC), 0.7991. The miRNA-423-5p (miR-423-5p) detection was: pooled sensitivity, 0.81 (95%CI, 0.76 to 0.85); pooled specificity, 0.67 (95%CI, 0.61 to 0.73); and SROC, 0.8600. However, taken the same patients population, we extracted the data of BNP for detecting heart failure and performed meta-analysis with acceptable SROC as 0.9291. Among the variance analysis, the diagnostic performance of miR-423-5p claimed significant advantages of other pooled results. However, the combination of miRNAs and BNP could increase the accuracy of detecting of heart failure. Unfortunately, there was no dramatic advantage of miR-423-5p compared to BNP protocol. Conclusion: Despite interstudy variability, the performance test of miRNA for detecting heart failure revealed that miR-423-5p demonstrated the potential to be a biomarker. However, other miRNAs were not able to provide enough evidence on promising diagnostic value for heart failure based on the current data. Moreover, the combination of miRNAs and BNP could work as a better method to detection. Unfortunately, BNP was still the most convinced biomarker for such disease. PMID:28562533

  11. Chemical and Thermal Analysis

    NASA Technical Reports Server (NTRS)

    Bulluck, J. W.; Rushing, R. A.

    1995-01-01

    During the past six months we have conducted significant research in several domains in order to clarify and understanding the aging and chemical failure mechanism of thermoplastics (PVDF or Tefzel) for pipes. We organized numerous analytical studies with methods including Fourier Transform Infrared Spectroscopy, Dynamic Mechanical Analysis, Differential Scanning Calorimetry, and Stress Relaxation experiments. In addition we have reanalyzed previous thermogravimetric data concerning the rate of deplasticization of Coflon pipe. We investigated a number of aged samples of both Tefzel and Coflon that were forwarded from MERL. We conducted stress relaxation experiments of Coflon pipe at several temperatures and determined an activation energy. We also examined the dynamic mechanical response PVDF during deplasticization and during methanol plasticization. We performed numerous DSC analyses to research the changing crystalline morphology. We have noted significant changes in crystallinity upon aging for both PVDF and Tefzel. Little variation in elemental composition was noted for many of the aged Coflon and Tefzel samples tested.

  12. Application of Diagnostic Analysis Tools to the Ares I Thrust Vector Control System

    NASA Technical Reports Server (NTRS)

    Maul, William A.; Melcher, Kevin J.; Chicatelli, Amy K.; Johnson, Stephen B.

    2010-01-01

    The NASA Ares I Crew Launch Vehicle is being designed to support missions to the International Space Station (ISS), to the Moon, and beyond. The Ares I is undergoing design and development utilizing commercial-off-the-shelf tools and hardware when applicable, along with cutting edge launch technologies and state-of-the-art design and development. In support of the vehicle s design and development, the Ares Functional Fault Analysis group was tasked to develop an Ares Vehicle Diagnostic Model (AVDM) and to demonstrate the capability of that model to support failure-related analyses and design integration. One important component of the AVDM is the Upper Stage (US) Thrust Vector Control (TVC) diagnostic model-a representation of the failure space of the US TVC subsystem. This paper first presents an overview of the AVDM, its development approach, and the software used to implement the model and conduct diagnostic analysis. It then uses the US TVC diagnostic model to illustrate details of the development, implementation, analysis, and verification processes. Finally, the paper describes how the AVDM model can impact both design and ground operations, and how some of these impacts are being realized during discussions of US TVC diagnostic analyses with US TVC designers.

  13. Multimaterial lamination as a means of retarding penetration and spallation failures in plates

    NASA Technical Reports Server (NTRS)

    Dibattista, J. D.; Humes, D. H.

    1972-01-01

    Experimental data are presented which show that hypervelocity impact spallation and penetration failures of a single solid aluminum plate and of a solid aluminum plate spaced a distance behind a Whipple meteor bumper may be retarded by replacing the solid aluminum plate with a laminated plate. Four sets of experiments were conducted. The first set of experiments was conducted with projectile mass and velocity held constant and with polycarbonate cylinders impacted into single plates of different construction. The second set of experiments was done with single plates of various construction and aluminum spherical projectiles of similar mass but different velocities. These two experiments showed that a laminated plate of aluminum and polycarbonate or aluminum and methyl methacrylate could prevent spallation and penetration failures with a lower areal density than either an all-aluminum laminated plate or a solid aluminum plate. The aluminum laminated plate was in turn superior to the solid aluminum plate in resisting spallation and penetration failures. In addition, through an example of 6061-T6 aluminum and methyl methacrylate, it is shown that a laminated structure ballistically superior to its parent materials may be built. The last two sets of experiments were conducted using bumper-protected main walls of solid aluminum and of laminated aluminum and polycarbonate. Again, under hypervelocity impact conditions, the laminated main walls were superior to the solid aluminum main walls in retarding spallation and penetration failures.

  14. Risk management of key issues of FPSO

    NASA Astrophysics Data System (ADS)

    Sun, Liping; Sun, Hai

    2012-12-01

    Risk analysis of key systems have become a growing topic late of because of the development of offshore structures. Equipment failures of offloading system and fire accidents were analyzed based on the floating production, storage and offloading (FPSO) features. Fault tree analysis (FTA), and failure modes and effects analysis (FMEA) methods were examined based on information already researched on modules of relex reliability studio (RRS). Equipment failures were also analyzed qualitatively by establishing a fault tree and Boolean structure function based on the shortage of failure cases, statistical data, and risk control measures examined. Failure modes of fire accident were classified according to the different areas of fire occurrences during the FMEA process, using risk priority number (RPN) methods to evaluate their severity rank. The qualitative analysis of FTA gave the basic insight of forming the failure modes of FPSO offloading, and the fire FMEA gave the priorities and suggested processes. The research has practical importance for the security analysis problems of FPSO.

  15. The clinical implications of elevated blood metal ion concentrations in asymptomatic patients with MoM hip resurfacings: a cohort study

    PubMed Central

    Langton, David J; Sidaginamale, Raghavendra P; Joyce, Thomas J; Natu, Shonali; Blain, Peter; Jefferson, Robert Drysdale; Rushton, Stephen; Nargol, Antoni V F

    2013-01-01

    Objective To determine whether elevated blood cobalt (Co) concentrations are associated with early failure of metal-on-metal (MoM) hip resurfacings secondary to adverse reaction to metal debris (ARMD). Design Cohort study. Setting Single centre orthopaedic unit. Participants Following the identification of complications potentially related to metal wear debris, a blood metal ion screening programme was instigated at our unit in 2007 for all patients with Articular Surface Replacement (ASR) and Birmingham MoM hip resurfacings. Patients were followed annually unless symptoms presented earlier. Symptomatic patients were investigated with ultrasound scan and joint aspiration. The clinical course of all 278 patients with ‘no pain’ or ‘slight/occasional’ pain and a Harris Hip Score greater than or equal to 95 at the time of venesection were documented. A retrospective analysis was subsequently conducted using mixed effect modelling to investigate the temporal pattern of blood Co levels in the patients and survival analysis to investigate the potential role of case demographics and blood Co levels as risk factors for subsequent failure secondary to ARMD. Results Blood Co concentration was a positive and significant risk factor (z=8.44, p=2×10–16) for joint failure, as was the device, where the Birmingham Hip Resurfacing posed a significantly reduced risk for revision by 89% (z=−3.445, p=0.00005 (95% CI on risk 62 to 97)). Analysis using Cox-proportional hazards models indicated that men had a 66% lower risk of joint failure than women (z=−2.29419, p=0.0218, (95% CI on risk reduction 23 to 89)). Conclusions The results suggest that elevated blood metal ion concentrations are associated with early failure of MoM devices secondary to adverse reactions to metal debris. Co concentrations greater than 20 µg/l are frequently associated with metal staining of tissues and the development of osteolysis. Development of soft tissue damage appears to be more complex with females and patients with ASR devices seemingly more at risk when exposed to equivalent doses of metal debris. PMID:23482990

  16. Sensor transition failure in the high flow sampler: Implications for methane emission inventories of natural gas infrastructure.

    PubMed

    Howard, Touché; Ferrara, Thomas W; Townsend-Small, Amy

    2015-07-01

    Quantification of leaks from natural gas (NG) infrastructure is a key step in reducing emissions of the greenhouse gas methane (CH4), particularly as NG becomes a larger component of domestic energy supply. The U.S. Environmental Protection Agency (EPA) requires measurement and reporting of emissions of CH4 from NG transmission, storage, and processing facilities, and the high-flow sampler (or high-volume sampler) is one of the tools approved for this by the EPA. The Bacharach Hi-Flow Sampler (BHFS) is the only commercially available high-flow instrument, and it is also used throughout the NG supply chain for directed inspection and maintenance, emission factor development, and greenhouse gas reduction programs. Here we document failure of the BHFS to transition from a catalytic oxidation sensor used to measure low NG (~5% or less) concentrations to a thermal conductivity sensor for higher concentrations (from ~5% to 100%), resulting in underestimation of NG emission rates. Our analysis includes both our own field testing and analysis of data from two other studies (Modrak et al., 2012; City of Fort Worth, 2011). Although this failure is not completely understood, and although we do not know if all BHFS models are similarly affected, sensor transition failure has been observed under one or more of these conditions: (1) Calibration is more than ~2 weeks old; (2) firmware is out of date; or (3) the composition of the NG source is less than ~91% CH4. The extent to which this issue has affected recent emission studies is uncertain, but the analysis presented here suggests that the problem could be widespread. Furthermore, it is critical that this problem be resolved before the onset of regulations on CH4 emissions from the oil and gas industry, as the BHFS is a popular instrument for these measurements. An instrument commonly used to measure leaks in natural gas infrastructure has a critical sensor transition failure issue that results in underestimation of leaks, with implications for greenhouse gas emissions estimates as well as safety.

  17. Extended Testability Analysis Tool

    NASA Technical Reports Server (NTRS)

    Melcher, Kevin; Maul, William A.; Fulton, Christopher

    2012-01-01

    The Extended Testability Analysis (ETA) Tool is a software application that supports fault management (FM) by performing testability analyses on the fault propagation model of a given system. Fault management includes the prevention of faults through robust design margins and quality assurance methods, or the mitigation of system failures. Fault management requires an understanding of the system design and operation, potential failure mechanisms within the system, and the propagation of those potential failures through the system. The purpose of the ETA Tool software is to process the testability analysis results from a commercial software program called TEAMS Designer in order to provide a detailed set of diagnostic assessment reports. The ETA Tool is a command-line process with several user-selectable report output options. The ETA Tool also extends the COTS testability analysis and enables variation studies with sensor sensitivity impacts on system diagnostics and component isolation using a single testability output. The ETA Tool can also provide extended analyses from a single set of testability output files. The following analysis reports are available to the user: (1) the Detectability Report provides a breakdown of how each tested failure mode was detected, (2) the Test Utilization Report identifies all the failure modes that each test detects, (3) the Failure Mode Isolation Report demonstrates the system s ability to discriminate between failure modes, (4) the Component Isolation Report demonstrates the system s ability to discriminate between failure modes relative to the components containing the failure modes, (5) the Sensor Sensor Sensitivity Analysis Report shows the diagnostic impact due to loss of sensor information, and (6) the Effect Mapping Report identifies failure modes that result in specified system-level effects.

  18. Cross-Cultural Adaptation and Psychometric Testing of the Brazilian Version of the Self-Care of Heart Failure Index Version 6.2

    PubMed Central

    Ávila, Christiane Wahast; Riegel, Barbara; Pokorski, Simoni Chiarelli; Camey, Suzi; Silveira, Luana Claudia Jacoby; Rabelo-Silva, Eneida Rejane

    2013-01-01

    Objective. To adapt and evaluate the psychometric properties of the Brazilian version of the SCHFI v 6.2. Methods. With the approval of the original author, we conducted a complete cross-cultural adaptation of the instrument (translation, synthesis, back translation, synthesis of back translation, expert committee review, and pretesting). The adapted version was named Brazilian version of the self-care of heart failure index v 6.2. The psychometric properties assessed were face validity and content validity (by expert committee review), construct validity (convergent validity and confirmatory factor analysis), and reliability. Results. Face validity and content validity were indicative of semantic, idiomatic, experimental, and conceptual equivalence. Convergent validity was demonstrated by a significant though moderate correlation (r = −0.51) on comparison with equivalent question scores of the previously validated Brazilian European heart failure self-care behavior scale. Confirmatory factor analysis supported the original three-factor model as having the best fit, although similar results were obtained for inadequate fit indices. The reliability of the instrument, as expressed by Cronbach's alpha, was 0.40, 0.82, and 0.93 for the self-care maintenance, self-care management, and self-care confidence scales, respectively. Conclusion. The SCHFI v 6.2 was successfully adapted for use in Brazil. Nevertheless, further studies should be carried out to improve its psychometric properties. PMID:24163765

  19. Outcomes of a Failure Mode and Effects Analysis for medication errors in pediatric anesthesia.

    PubMed

    Martin, Lizabeth D; Grigg, Eliot B; Verma, Shilpa; Latham, Gregory J; Rampersad, Sally E; Martin, Lynn D

    2017-06-01

    The Institute of Medicine has called for development of strategies to prevent medication errors, which are one important cause of preventable harm. Although the field of anesthesiology is considered a leader in patient safety, recent data suggest high medication error rates in anesthesia practice. Unfortunately, few error prevention strategies for anesthesia providers have been implemented. Using Toyota Production System quality improvement methodology, a multidisciplinary team observed 133 h of medication practice in the operating room at a tertiary care freestanding children's hospital. A failure mode and effects analysis was conducted to systematically deconstruct and evaluate each medication handling process step and score possible failure modes to quantify areas of risk. A bundle of five targeted countermeasures were identified and implemented over 12 months. Improvements in syringe labeling (73 to 96%), standardization of medication organization in the anesthesia workspace (0 to 100%), and two-provider infusion checks (23 to 59%) were observed. Medication error reporting improved during the project and was subsequently maintained. After intervention, the median medication error rate decreased from 1.56 to 0.95 per 1000 anesthetics. The frequency of medication error harm events reaching the patient also decreased. Systematic evaluation and standardization of medication handling processes by anesthesia providers in the operating room can decrease medication errors and improve patient safety. © 2017 John Wiley & Sons Ltd.

  20. A method for producing digital probabilistic seismic landslide hazard maps

    USGS Publications Warehouse

    Jibson, R.W.; Harp, E.L.; Michael, J.A.

    2000-01-01

    The 1994 Northridge, California, earthquake is the first earthquake for which we have all of the data sets needed to conduct a rigorous regional analysis of seismic slope instability. These data sets include: (1) a comprehensive inventory of triggered landslides, (2) about 200 strong-motion records of the mainshock, (3) 1:24 000-scale geologic mapping of the region, (4) extensive data on engineering properties of geologic units, and (5) high-resolution digital elevation models of the topography. All of these data sets have been digitized and rasterized at 10 m grid spacing using ARC/INFO GIS software on a UNIX computer. Combining these data sets in a dynamic model based on Newmark's permanent-deformation (sliding-block) analysis yields estimates of coseismic landslide displacement in each grid cell from the Northridge earthquake. The modeled displacements are then compared with the digital inventory of landslides triggered by the Northridge earthquake to construct a probability curve relating predicted displacement to probability of failure. This probability function can be applied to predict and map the spatial variability in failure probability in any ground-shaking conditions of interest. We anticipate that this mapping procedure will be used to construct seismic landslide hazard maps that will assist in emergency preparedness planning and in making rational decisions regarding development and construction in areas susceptible to seismic slope failure. ?? 2000 Elsevier Science B.V. All rights reserved.

Top